WorldWideScience

Sample records for water transmission loss

  1. Sound transmission loss of composite sandwich panels

    Science.gov (United States)

    Zhou, Ran

    Light composite sandwich panels are increasingly used in automobiles, ships and aircraft, because of the advantages they offer of high strength-to-weight ratios. However, the acoustical properties of these light and stiff structures can be less desirable than those of equivalent metal panels. These undesirable properties can lead to high interior noise levels. A number of researchers have studied the acoustical properties of honeycomb and foam sandwich panels. Not much work, however, has been carried out on foam-filled honeycomb sandwich panels. In this dissertation, governing equations for the forced vibration of asymmetric sandwich panels are developed. An analytical expression for modal densities of symmetric sandwich panels is derived from a sixth-order governing equation. A boundary element analysis model for the sound transmission loss of symmetric sandwich panels is proposed. Measurements of the modal density, total loss factor, radiation loss factor, and sound transmission loss of foam-filled honeycomb sandwich panels with different configurations and thicknesses are presented. Comparisons between the predicted sound transmission loss values obtained from wave impedance analysis, statistical energy analysis, boundary element analysis, and experimental values are presented. The wave impedance analysis model provides accurate predictions of sound transmission loss for the thin foam-filled honeycomb sandwich panels at frequencies above their first resonance frequencies. The predictions from the statistical energy analysis model are in better agreement with the experimental transmission loss values of the sandwich panels when the measured radiation loss factor values near coincidence are used instead of the theoretical values for single-layer panels. The proposed boundary element analysis model provides more accurate predictions of sound transmission loss for the thick foam-filled honeycomb sandwich panels than either the wave impedance analysis model or the

  2. Flooding in ephemeral streams: incorporating transmission losses

    Science.gov (United States)

    Stream flow in semiarid lands commonly occurs as a form of flash floods in dry ephemeral stream beds. The goal of this research is to couple hydrological and hydraulic models treats channel transmission losses and test the methodology in the USDA-ARS Walnut Gulch Experimental Watershed (WGEW). For h...

  3. A unified transmission loss allocation method

    International Nuclear Information System (INIS)

    Ding, Qifeng; Abur, Ali

    2007-01-01

    A new unified method which allocates transmission losses either to buses in a pool market or to individual transactions in a bilateral contract market is presented in this paper. A detailed derivation of the method is given. A bus-loss matrix and a transaction-loss matrix are developed to show the interactions between bus injections and transactions. It is further demonstrated that the ''Physical-power-flow-based'' method can be obtained as an approximation of this unified approach under certain simplifying assumptions. Test systems are used to illustrate how the proposed method behaves under different possible scenarios. (author)

  4. Transmission loss optimization in acoustic sandwich panels

    Science.gov (United States)

    Makris, S. E.; Dym, C. L.; MacGregor Smith, J.

    1986-06-01

    Considering the sound transmission loss (TL) of a sandwich panel as the single objective, different optimization techniques are examined and a sophisticated computer program is used to find the optimum TL. Also, for one of the possible case studies such as core optimization, closed-form expressions are given between TL and the core-design variables for different sets of skins. The significance of these functional relationships lies in the fact that the panel designer can bypass the necessity of using a sophisticated software package in order to assess explicitly the dependence of the TL on core thickness and density.

  5. Frequency Dependent Losses in Transmission Cable Conductors

    DEFF Research Database (Denmark)

    Olsen, Rasmus Schmidt; Holbøll, Joachim; Guðmundsdóttir, Unnur Stella

    2011-01-01

    , such as thermal conditions in and around the cable, as well as the heat generated in conductors, screens, armours etc., taking into account proximity and skin effects. The work performed and presented in this paper is concerned with an improved determination of the losses generated in the conductor, by means...... of better calculation of the AC resistance of transmission cable conductors, in particular regarding higher frequencies. In this way, also losses under harmonics can be covered. Furthermore, the model is suitable for modelling of transient attenuation in high voltage cables. The AC resistance is calculated...... based on the current density distribution in different conductor designs by means of the Finite Element Method (FEM). The obtained results and methods are compared to available standards (IEC publication 60287-1-1)....

  6. Water Loss in Small Settlements

    OpenAIRE

    Mindaugas Rimeika; Anželika Jurkienė

    2014-01-01

    The main performance indicators of a water supply system include the quality and safety of water, continuous work, relevant pressure and small water loss. The majority of foreign and local projects on reducing water loss have been carried out in the water supply systems of metropolitans; however, the specificity of small settlements differs from that of big cities. Differences can be observed not only in the development of infrastructure and technical indicators but also in the features of wa...

  7. Energy losses of superconducting power transmission cables in the grid

    DEFF Research Database (Denmark)

    Østergaard, Jacob; Okholm, Jan; Lomholt, Karin

    2001-01-01

    One of the obvious motives for development of superconducting power transmission cables is reduction of transmission losses. Loss components in superconducting cables as well as in conventional cables have been examined. These losses are used for calculating the total energy losses of conventional...... as well as superconducting cables when they are placed in the electric power transmission network. It is concluded that high load connections are necessary to obtain energy saving by the use of HTSC cables. For selected high load connections, an energy saving of 40% is expected. It is shown...

  8. Airborne sound transmission loss characteristics of wood-frame construction

    Science.gov (United States)

    Rudder, F. F., Jr.

    1985-03-01

    This report summarizes the available data on the airborne sound transmission loss properties of wood-frame construction and evaluates the methods for predicting the airborne sound transmission loss. The first part of the report comprises a summary of sound transmission loss data for wood-frame interior walls and floor-ceiling construction. Data bases describing the sound transmission loss characteristics of other building components, such as windows and doors, are discussed. The second part of the report presents the prediction of the sound transmission loss of wood-frame construction. Appropriate calculation methods are described both for single-panel and for double-panel construction with sound absorption material in the cavity. With available methods, single-panel construction and double-panel construction with the panels connected by studs may be adequately characterized. Technical appendices are included that summarize laboratory measurements, compare measurement with theory, describe details of the prediction methods, and present sound transmission loss data for common building materials.

  9. DGA-based VAR rescheduling for transmission loss reduction

    Energy Technology Data Exchange (ETDEWEB)

    Mishra, S. [Indian Inst. of Technology, Delhi (India); Taylor, G.A. [Brunel Univ., London (United Kingdom). Brunel Inst. of Power Systems; Reddy, J.B.V. [Government of India, New Delhi (India). Dept. of Science and Technology; Naeem, M.H. [Multimedia Univ. (Malaysia). Faculty of Engineering

    2009-07-01

    Power losses in power transmission lines can be minimized by adjusting transformer taps and switchable VAR sources. Optimal power flow (OPF) is a static, nonlinear, multi-objective optimization challenge in which the optimal settings of control variables must be determined for minimizing the cost of generation, emissions, transmission losses and voltage and power flow deviations. OPF is important in power system operation because a small savings per hour can mean a large annual savings. This paper presented a method to reduce transmission power losses using a Differential Genetic Algorithm (DGA) for VAR rescheduling. The New England 39-bus power system was used as a test case. Power losses were minimized by changing the tap settings of various transformers and by varying the injected reactive power. The paper showed that certain buses in the system can improve the voltage profile and reduce transmission losses through reactive power injections from capacitor banks. In this study, minimum reactive power output of generators was maintained at zero to ensure that the generators did not draw reactive power. The DGA was shown to produce better results than the Conventional Genetic Algorithm in terms of power loss minimization. 12 refs., 1 tab., 2 figs.

  10. Simulation of loss electron in vacuum magnetically insulated transmission lines

    International Nuclear Information System (INIS)

    Zhang Pengfei; Li Yongdong; Liu Chunliang; Wang Hongguang; Guo Fan; Yang Hailiang; Qiu Aici; Su Zhaofeng; Sun Jianfeng; Sun Jiang; Gao Yi

    2011-01-01

    In the beginning of magnetic insulated period, loss electron in coaxial vacuum magnetically insulated transmission line (MITL) strikes anode and the bremsstrahlung photons are generated in the mean time. Based on the self-limited flow model, velocity in direction of energy transport, energy spectrum and angular distribution of loss electron are simulated by PIC code, energy spectrum of bremsstrahlung photons as well calculated though Monte Carlo method. Computational results show that the velocity of loss electron is less than 2.998 x 108 m/s, the angular excursion of electron is not much in a board extent of energy spectrum. These results show an indirect diagnosis of vacuum insulted transmission line working status based on loss electron bremsstrahlung. (authors)

  11. Cost Allocation of Transmission Losses in Electric Market Mechanism

    Directory of Open Access Journals (Sweden)

    Erwin Dermawan

    2012-06-01

    Full Text Available This paper proposes a new method to calculate cost allocation of transmission losses (losses, based on a certain price of energy (i.e. a marginal price of system. Here is developed a mathematic model through manipulating of the network equation to separate losses. This model uses complex power injection and, does not use approximations and assumptions in determining the cost allocation of losses. Its calculation begins from the results of load flow calculation and then is continued to calculate power distribution from a generator to every load and every line. Finally, to be calculated separating of losses and cost allocation of losses. The proposed method is easy to be understood and applied. An illustration results on IEEE 14-bus system show that the method is always consistent with expectancies and somewhat different with a few reference methods.

  12. Water Loss from Young Planets

    Science.gov (United States)

    Tian, Feng; Güdel, Manuel; Johnstone, Colin P.; Lammer, Helmut; Luger, Rodrigo; Odert, Petra

    2018-04-01

    Good progress has been made in the past few years to better understand the XUV evolution trend of Sun-like stars, the capture and dissipation of hydrogen dominant envelopes of planetary embryos and protoplanets, and water loss from young planets around M dwarfs. This chapter reviews these recent developments. Observations of exoplanets and theoretical works in the near future will significantly advance our understanding of one of the fundamental physical processes shaping the evolution of solar system terrestrial planets.

  13. Transmission loss of double wall panels containing Helmholtz resonators

    Science.gov (United States)

    Prydz, R. A.; Kuntz, H. L.; Morrow, D. L.; Wirt, L. S.

    Data and an analysis are presented on the use of Helholtz resonators in double wall panels (i.e., aircraft sidewalls). Several wall materials and resonator configurations were tested, and the resonators were found to substantially increase the transmission loss of the double wall system at the tuning frequency.

  14. Microparticle-initiated losses in magnetically insulated transmission lines

    International Nuclear Information System (INIS)

    Gray, E.W.; Stinnett, R.W.

    1986-01-01

    The author's discuss the effects of high and hypervelocity microparticles in magnetically-insulated transmission lines (MITLs) and how they may be a possible source for ion production near the anode in early stages of the voltage pulse, and current carriers during and after the power pulse, resulting in power flow losses. Early losses in the voltage pulse, due to microparticles, are estimated to be approximately 0.3 mA/cm/sup 2/. Blistering of the electrode surface, thought to be due to H/sup -/ bombardment, was also observed and appears to be consistent with losses due to negative ions previously reported by one of the authors

  15. Determining Transmission Loss from Measured External and Internal Acoustic Environments

    Science.gov (United States)

    Scogin, Tyler; Smith, A. M.

    2012-01-01

    An estimate of the internal acoustic environment in each internal cavity of a launch vehicle is needed to ensure survivability of Space Launch System (SLS) avionics. Currently, this is achieved by using the noise reduction database of heritage flight vehicles such as the Space Shuttle and Saturn V for liftoff and ascent flight conditions. Marshall Space Flight Center (MSFC) is conducting a series of transmission loss tests to verify and augment this method. For this test setup, an aluminum orthogrid curved panel representing 1/8th of the circumference of a section of the SLS main structure was mounted in between a reverberation chamber and an anechoic chamber. Transmission loss was measured across the panel using microphones. Data measured during this test will be used to estimate the internal acoustic environments for several of the SLS launch vehicle internal spaces.

  16. Theoretical analysis of sound transmission loss through graphene sheets

    International Nuclear Information System (INIS)

    Natsuki, Toshiaki; Ni, Qing-Qing

    2014-01-01

    We examine the potential of using graphene sheets (GSs) as sound insulating materials that can be used for nano-devices because of their small size, super electronic, and mechanical properties. In this study, a theoretical analysis is proposed to predict the sound transmission loss through multi-layered GSs, which are formed by stacks of GS and bound together by van der Waals (vdW) forces between individual layers. The result shows that the resonant frequencies of the sound transmission loss occur in the multi-layered GSs and the values are very high. Based on the present analytical solution, we predict the acoustic insulation property for various layers of sheets under both normal incident wave and acoustic field of random incidence source. The scheme could be useful in vibration absorption application of nano devices and materials

  17. Theoretical analysis of sound transmission loss through graphene sheets

    Energy Technology Data Exchange (ETDEWEB)

    Natsuki, Toshiaki, E-mail: natsuki@shinshu-u.ac.jp [Faculty of Textile Science and Technology, Shinshu University, 3-15-1 Tokida, Ueda 386-8567 (Japan); Institute of Carbon Science and Technology, Shinshu University, 4-17-1 Wakasato, Nagano 380-8553 (Japan); Ni, Qing-Qing [Faculty of Textile Science and Technology, Shinshu University, 3-15-1 Tokida, Ueda 386-8567 (Japan)

    2014-11-17

    We examine the potential of using graphene sheets (GSs) as sound insulating materials that can be used for nano-devices because of their small size, super electronic, and mechanical properties. In this study, a theoretical analysis is proposed to predict the sound transmission loss through multi-layered GSs, which are formed by stacks of GS and bound together by van der Waals (vdW) forces between individual layers. The result shows that the resonant frequencies of the sound transmission loss occur in the multi-layered GSs and the values are very high. Based on the present analytical solution, we predict the acoustic insulation property for various layers of sheets under both normal incident wave and acoustic field of random incidence source. The scheme could be useful in vibration absorption application of nano devices and materials.

  18. Transmission Loss Calculation using A and B Loss Coefficients in Dynamic Economic Dispatch Problem

    Science.gov (United States)

    Jethmalani, C. H. Ram; Dumpa, Poornima; Simon, Sishaj P.; Sundareswaran, K.

    2016-04-01

    This paper analyzes the performance of A-loss coefficients while evaluating transmission losses in a Dynamic Economic Dispatch (DED) Problem. The performance analysis is carried out by comparing the losses computed using nominal A loss coefficients and nominal B loss coefficients in reference with load flow solution obtained by standard Newton-Raphson (NR) method. Density based clustering method based on connected regions with sufficiently high density (DBSCAN) is employed in identifying the best regions of A and B loss coefficients. Based on the results obtained through cluster analysis, a novel approach in improving the accuracy of network loss calculation is proposed. Here, based on the change in per unit load values between the load intervals, loss coefficients are updated for calculating the transmission losses. The proposed algorithm is tested and validated on IEEE 6 bus system, IEEE 14 bus, system IEEE 30 bus system and IEEE 118 bus system. All simulations are carried out using SCILAB 5.4 (www.scilab.org) which is an open source software.

  19. Energy losses in magnetically insulated transmission lines due to microparticles

    International Nuclear Information System (INIS)

    Gray, E.W.; Stinnett, R.W.

    1987-01-01

    We discuss the effects of high-velocity and hypervelocity microparticles in the magnetically insulated transmission lines of multiterawatt accelerators used for particle beam fusion and radiation effects simulation. These microparticles may be a possible source for plasma production near the anode and cathode in early stages of the voltage pulse, and current carriers during and after the power pulse, resulting in power flow losses. Losses in the current pulse, due to microparticles, are estimated to be approximately 12 mA/cm 2 (0.3 kA) as a lower limit, and --0.3 A/cm 2 (7.2 kA) for microparticle initiated, anode plasma positive ion transport. We have calculated the velocities reached by these microparticles and the effects on them of Van der Waals forces. Field emission from the particles and their effects on cathode and anode plasma formation have been examined. Particle collision with the electrodes is also examined in terms of plasma production, as in the electron deposition in the particles in transit across the anode-cathode gap. Blistering of the electrode surface, thought to be due to H - bombardment was also observed and appears to be consistent with losses due to negative ions previously reported by J. P. VanDevender, R. W. Stinnett, and R. J. Anderson [App. Phys. Lett. 38, 229 (1981)

  20. Transmission loss of plates with embedded acoustic black holes.

    Science.gov (United States)

    Feurtado, Philip A; Conlon, Stephen C

    2017-09-01

    In recent years acoustic black holes (ABHs) have been developed and demonstrated as an effective method for developing lightweight, high loss structures for noise and vibration control. ABHs employ a local thickness change to tailor the speed and amplitude of flexural bending waves and create concentrated regions of high strain energy which can be effectively dissipated through conventional damping treatments. These regions act as energy sinks which allow for effective broadband vibration absorption with minimal use of applied damping material. This, combined with the reduced mass from the thickness tailoring, results in a treated structure with higher loss and less mass than the original. In this work, the transmission loss (TL) of plates with embedded ABHs was investigated using experimental and numerical methods in order to assess the usefulness of ABH systems for TL applications. The results demonstrated that damped ABH plates offer improved performance compared to a uniform plate despite having less mass. The result will be useful for applying ABHs and ABH systems to practical noise and vibration control problems.

  1. Improvement in transmission loss of aircraft double wall with resonators

    Science.gov (United States)

    Sun, Jincai; Shi, Liming; Ye, Xining

    1991-08-01

    A little volume low frequency resonator applicable to double-wall configuration of propeller-driven aircraft was designed on the basis of the principle of Helmholtz resonator. The normal incidence absorption coefficient of the various single resonator has been measured. The agreement between theoretical and experimental results is encouraging. An array of resonators whose resonant frequency at 85 Hz and 160 Hz, respectively, are installed between aircraft double-panel, and it has been shown that transmission loss of the double wall structure with resonators improve 4 dB and 6.5 dB in 1/3rd octave bandwidth at 80 Hz and 160 Hz center frequency, respectively, and 5 dB and 7 dB at resonant frequencies, compared with that of the double wall configuration without resonators.

  2. Modelling of channel transmission loss processes in semi-arid catchments of southern Africa using the Pitman Model

    Directory of Open Access Journals (Sweden)

    V. Mvandaba

    2018-05-01

    Full Text Available Water availability is one of the major societal issues facing the world. The ability to understand and quantify the impact of key hydrological processes, on the availability of water resources, is therefore integral to ensuring equitable and sustainable resource management. Channel transmission losses are an under-researched hydrological process that affects resource availability in many semi-arid regions such as the Limpopo River Basin in southern Africa, where the loss processes amount to approximately 30 % of the water balance. To improve the understanding of these loss processes and test the capability of modelling routines, three approaches using the Pitman model are applied to selected alluvial aquifer environments. The three approaches are an explicit transmission loss function, the use of a wetland function to represent channel-floodplain storage exchanges and the use of a dummy reservoir to represent floodplain storage and evapotranspiration losses. Results indicate that all three approaches are able to simulate channel transmission losses with differing impacts on the regional flows. A determination of which method best represents the channel transmission losses process requires further testing in a study area that has reliable observed historical records.

  3. Loss of aphid transmissibility of plum pox virus isolates

    NARCIS (Netherlands)

    Kamenova, I.; Lohuis, H.; Peters, D.

    2002-01-01

    The aphid transmissibility of seven Plum pox virus (PPV) isolates and the amino acid sequences of their coat proteins were analysed Two aphid transmissible isolates PPV-A and PPV-P contained the DAG amino triplet, while DAL or NAG replaced this triplet in the coat proteins of non-aphid transmissible

  4. Guidelines for transient analysis in water transmission and distribution systems

    NARCIS (Netherlands)

    Pothof, I.W.M.; Karney, B.W.

    2012-01-01

    All water systems leak, and many supply systems do so considerably, with water losses typically of approximately 20% of the water production. The IWA Water Loss Task Force aims for a significant reduction of annual water losses by drafting documents to assist practitioners and others to prevent,

  5. Reducing water losses via intelligent pressure management; Reduzierung von Wasserverlusten durch intelligentes Druckmanagement

    Energy Technology Data Exchange (ETDEWEB)

    Oppinger, Peter [VAG-Armaturen GmbH, Mannheim (Germany). Marketing

    2008-03-15

    Leaks in water pipes and leaking municipal water-transmission and piping systems, particularly in developing and threshold countries account for water-losses of up to 50% of the water supplied by the waterworks. This article examines three different solutions for effective pressure management on the basis of an intelligent control system, by means of which water-losses can be reduced to a stable and economically rational level. (orig.)

  6. Optimasi Kualitas Akustik Room to Room Berdasarkan Nilai Transmission Loss

    Directory of Open Access Journals (Sweden)

    Fitri Rachmawati

    2013-09-01

    Full Text Available Kamar tidur merupakan salah satu fasilitas utama yang disediakan pada sebuah hotel. Fasilitas ini membutuhkan kenyamanan dan ruangan yang bersifat privasi dimana privasi berkaitan dengan aspek suara yaitu bising (noise. Tingkat kebisingan pada kamar harus diatur dengan adanya insulasi suara agar tidak mengganggu kenyamanan pengunjung saat beristirahat. Nilai insulasi ini dapat digambarkan dengan transmission loss dimana nilai ini dapat diubah menjadi suatu nilai tunggal yang disebut dengan weighted sound reduction index (Rw, DnTw yang mempunyai penambahan faktor koreksi suara frekuensi rendah (C, Ctr. Pada penelitian ini dilakukan insulasi suara pada kamar tidur hotel di Bandara Juanda dengan meninjau aspek dinding partisi untuk menahan kebisingan antar ruangan kamar tidur. Hotel pada penelitian ini merupakan hotel low budget dengan kamar yang minimalis dan ditujukan untuk awak pesawat atau penumpang pesawat yang sedang transit. Walaupun minimalis, tetap diperlukan insulasi suara pada kamar yang baik sehingga dilakukan optimasi dinding partisi dengan ketentuan nilai DnTw+Ctr > 51 dB. Pengukuran pada penelitian ini dilakukan di 5 titik dengan menggunakan SLM RION dan SOLO pada saat malam hari. Berdasarkan hasil pengukuran, diketahui bahwa dinding partisi existing belum memenuhi standar dengan nilai DnTw+Ctr sebesar 35,8 dB sehingga dilakukan perancangan ulang dinding partisi. Perancangan ini menggunakan material gypsum board dan cement board dengan variasi ketebalan material serta cavity yang berbeda. Hasil perancangan yang terbaik yaitu dinding dari material cement board 12,5 mm dengan spesifikasi double panels pada masing-masing sisi dan lebar cavity 70 mm dimana menghasilkan nilai DnTw+Ctr sebesar 52,9 dB. Dengan hasil tersebut, maka dinding partisi sudah memenuhi standar dan mempunyai kualitas insulasi suara yang baik.

  7. Water loss in Mafraq governorate, Jordan

    OpenAIRE

    Al-Ansari, Nadhir; Al-Oun, Salem; Hadad, Wafa; Knutsson, Sven

    2013-01-01

    Jordan is located in the Middle East and covers an area of 89,342 km2. The total population of Jordan is 6,508,271. Jordan is rapidly facing a severe water supply crisis due to greater demands on a finite quantity of available water. If current trends continue, it has been estimated that the country will experience a chronic water shortage by 2020. Despite these shortages, water loss in the distribution network is relatively high where it reaches 46%. Mafraq Governorate has the maximum water ...

  8. Escape of atmospheres and loss of water

    International Nuclear Information System (INIS)

    Hunten, D.M.; Donahue, T.M.; Walker, J.C.G.; Kasting, J.F.

    1989-01-01

    The properties and limitations of several loss processes for atmospheric gases are presented and discussed. They include thermal loss (Jeans and hydrodynamic); nonthermal loss (all processes involve charged particles); and impact erosion, including thermal escape from a molten body heated by rapid accretion. Hydrodynamic escape, or blowoff, is of particular interest because it offers the prospect of processing large quantities of gas and enriching the remainder in heavy elements and isotopes. In a second part, the water budgets and likely evolutionary histories of Venus, Earth and Mars are assessed. Although it is tempting to associate the great D/H enrichment on Venus with loss of a large initial endowment, a steady state with juvenile water (perhaps from comets) is equally probable

  9. Prediction of transmission loss through an aircraft sidewall using statistical energy analysis

    Science.gov (United States)

    Ming, Ruisen; Sun, Jincai

    1989-06-01

    The transmission loss of randomly incident sound through an aircraft sidewall is investigated using statistical energy analysis. Formulas are also obtained for the simple calculation of sound transmission loss through single- and double-leaf panels. Both resonant and nonresonant sound transmissions can be easily calculated using the formulas. The formulas are used to predict sound transmission losses through a Y-7 propeller airplane panel. The panel measures 2.56 m x 1.38 m and has two windows. The agreement between predicted and measured values through most of the frequency ranges tested is quite good.

  10. Reduction of water losses by rehabilitation of water distribution network.

    Science.gov (United States)

    Güngör, Mahmud; Yarar, Ufuk; Firat, Mahmut

    2017-09-11

    Physical or real losses may be indicated as the most important component of the water losses occurring in a water distribution network (WDN). The objective of this study is to examine the effects of piping material management and network rehabilitation on the physical water losses and water losses management in a WDN. For this aim, the Denizli WDN consisting of very old pipes that have exhausted their economic life is selected as the study area. The fact that the current network is old results in the decrease of pressure strength, increase of failure intensity, and inefficient use of water resources thus leading to the application of the rehabilitation program. In Denizli, network renewal works have been carried out since the year 2009 under the rehabilitation program. It was determined that the failure rate at regions where network renewal constructions have been completed decreased down to zero level. Renewal of piping material enables the minimization of leakage losses as well as the failure rate. On the other hand, the system rehabilitation has the potential to amortize itself in a very short amount of time if the initial investment cost of network renewal is considered along with the operating costs of the old and new systems, as well as water loss costs. As a result, it can be stated that renewal of piping material in water distribution systems, enhancement of the physical properties of the system, provide significant contributions such as increase of water and energy efficiency and more effective use of resources.

  11. Water-loss dehydration and aging.

    Science.gov (United States)

    Hooper, Lee; Bunn, Diane; Jimoh, Florence O; Fairweather-Tait, Susan J

    2014-01-01

    This review defines water-loss and salt-loss dehydration. For older people serum osmolality appears the most appropriate gold standard for diagnosis of water-loss dehydration, but clear signs of early dehydration have not been developed. In older adults, lower muscle mass, reduced kidney function, physical and cognitive disabilities, blunted thirst, and polypharmacy all increase dehydration risk. Cross-sectional studies suggest a water-loss dehydration prevalence of 20-30% in this population. Water-loss dehydration is associated with higher mortality, morbidity and disability in older people, but evidence is still needed that this relationship is causal. There are a variety of ways we may be able to help older people reduce their risk of dehydration by recognising that they are not drinking enough, and being helped to drink more. Strategies to increase fluid intake in residential care homes include identifying and overcoming individual and institutional barriers to drinking, such as being worried about not reaching the toilet in time, physical inability to make or to reach drinks, and reduced social drinking and drinking pleasure. Research needs are discussed, some of which will be addressed by the FP7-funded NU-AGE (New dietary strategies addressing the specific needs of elderly population for a healthy ageing in Europe) trial. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  12. Water vapour loss measurements on human skin.

    NARCIS (Netherlands)

    Valk, Petrus Gerardus Maria van der

    1984-01-01

    In this thesis, the results of a series of investigations into the barrier function of human skin are presented. In these investigations, the barrier function was assessed by water vapour loss measurements of the skin using a method based on gradient estimation.... Zie: Summary and conclusions

  13. Evaporative water loss from welded tuff

    International Nuclear Information System (INIS)

    Hadley, G.R.; Turner, J.R. Jr.

    1980-04-01

    Welded tuff is one of the many candidate rocks presently being considered as a host medium for the disposal of radioactive waste. In the case where the disposal site lies above the water table, the host rock will in general be only partially saturated. This condition leads to a number of mass transfer processes of interest, including evaporative drying, two-phase water flow due to pressure gradients, capillary movement, plus others. Although these processes have all been known about for decades, it is not clear at this time what the relative importance of each is with regard to geologic media in a waste disposal environment. In particular, there seems to be no data available for tuff that would allow an investigator to sort out mechanisms. This work is intended to be a start in that direction. This paper reports the measurement of water loss rate for welded tuff at various temperatures due to the action of evaporative drying. The initial saturation was unknown, but the average initial water content was found to be 7% by weight. The resulting data show that the water loss rate declines monotonically with time at a given temperature and increases with increasing temperature as expected. Somewhat surprising, however, is the fact that over 90% of the water from a sample was lost by evaporation at room temperature within 72 hours. All the water loss data, including that taken at temperatures as high as 150 0 C, are explained to within a factor of two by a simple evaporation front model. The latter assumes the water is lost by the molecular diffusion of water vapor from a receding evaporation front. The motion of the evaporation front seems to depend on mass balance rather than energy balance. Capillary forces and the resulting liquid diffusion are evidently not strong enough to wash out the evaporation front, since the front model seems to fit the data well

  14. Minimization of transmission loss using distributed generation approach

    Directory of Open Access Journals (Sweden)

    Lamin Chaantrea Miky

    2018-01-01

    Full Text Available The goal of this work is to calculate the total loss in the system and minimize this loss by implementation of distributed generation (DG technology. In this paper, load flow analysis method is followed to calculate the loss in the system in conjunction with the line flows. A simple 5 bus system with the main bus of the substation as the slack bus, three Plant generators at the generator bus and three load buses are taken for analysis. For loss minimization two distributed generators at two load buses are connected. One generator is a synchronous type model and the other is asynchronous type model. We searched for the most economical penetration level and the ratings of the distributed generators are decided by the magnitude of penetration power at each load bus. Using software, power system simulation for electrical (PSSE, the system with and without DG technology is modeled and the output from the PSSE is observed.

  15. Water losses during technical snow production

    Science.gov (United States)

    Grünewald, Thomas; Wolfsperger, Fabian

    2017-04-01

    These days, the production of technical snow can be seen as a prerequisite for winter tourism. Huge amounts of water are used for technical snow production by ski resorts, especially in the beginning of the winter season. The aim is to guarantee an appropriate amount of snow to reliably provide optimal ski runs until the date of season opening in early December. Technical snow is generated by pumping pressurized water through the nozzles of a snow machine and dispersing the resulting spray of small water droplets which freeze during their travel to the ground. Cooling and freezing of the droplets can only happen if energy is emitted to the air mass surrounding the droplets. This heat transfer is happening through convective cooling and though evaporation and sublimation of water droplets and ice particles. This means that also mass is lost from the droplets and added in form of vapor to the air. It is important to note that not all water that is pumped through the snow machine is converted to snow distributed on the ground. Significant amounts of water are lost due to wind drift, sublimation and evaporation while droplets are traveling through the air or to draining of water which is not fully frozen when arriving at the ground. Studies addressing this question are sparse and the quantity of the water losses is still unclear. In order to assess this question in more detail, we obtained several systematic field observations at a test site near Davos, Switzerland. About a dozen of snow making tests had been performed during the last winter seasons. We compare the amount of water measured at the intake of the snow machine with the amount of snow accumulating at the ground during a night of snow production. The snow mass was calculated from highly detailed repeated terrestrial laser scanning measurements in combination with manually gathered snow densities. In addition a meteorological station had been set up in the vicinity observing all relevant meteorological

  16. A new data transmission system for deep water applications

    International Nuclear Information System (INIS)

    Brown, Gerald K.

    2000-01-01

    A novel data transmission system is now available. Conventional data transmission methods include systems that require satellites, hard wires, fiber optics and other methods that do not lend themselves to buried, remote, or deep water applications. The Data Transmission System (DTS) induces a signal into a structure such as the transmission line and retrieving the signal at a distant point. In deep water applications the power required comes from an anode array that generates its own power. In addition to deep water applications, the DTS can be used in onshore, drilling, and downhole applications. With repeater stations, most lengths of gathering and transmission lines can be used. Therefore data from control valves, strain gauges, corrosion monitoring, sand monitoring, valve position and other process variables can all be transmitted. Comparisons are made between the different data transmission systems showing the advantages and disadvantages of each type with comparative costs showing the advantages of the new DTS system. (author)

  17. Loss Aversion and the Asymmetric Transmission of Monetary Policy

    DEFF Research Database (Denmark)

    Santoro, Emiliano; Petrella, Ivan; Pfajfar, Damjan

    2014-01-01

    depends on consumption deviations from a reference level below which loss aversion is displayed. State-dependent degrees of real rigidity and elasticity of intertemporal substitution in consumption generate competing effects on output and inflation. Contractions face the Central Bank with higher...

  18. The use of acoustically tuned resonators to improve the sound transmission loss of double panel partitions

    Science.gov (United States)

    Mason, J. M.; Fahy, F. J.

    1986-10-01

    The effectiveness of tuned Helmholtz resonators connected to the partition cavity in double-leaf partitions utilized in situations requiring low weight structures with high transmission loss is investigated as a method of improving sound transmission loss. This is demonstrated by a simple theoretical model and then experimentally verified. Results show that substantial improvements may be obtained at and around the mass-air-mass frequency for a total resonator volume 15 percent of the cavity volume.

  19. Low loss mid-IR transmission bands using silica hollow-core anisotropic anti-resonant fibers

    DEFF Research Database (Denmark)

    Habib, Selim; Bang, Ole; Bache, Morten

    2016-01-01

    In this paper, a node-free anisotropic hollow-core anti-resonant fiber has been proposed to give low transmission loss in the near-IR to mid-IR spectral regime. The proposed silica-based fiber design shows transmission loss below 10 dB/km at 2.94 μm with multiple low loss transmission bands. Tran...

  20. Implementing tactical plans to improve water-energy loss management

    OpenAIRE

    Loureiro, D.; Alegre, H.; Silva, M. S.; Ribeiro, R.; Mamade, A.; Poças, A.

    2015-01-01

    Water utilities are aware of the water-energy loss relevance in supply systems. However, they still mainly focus on daily water loss control (real and apparent losses), without considering the impact on embedded energy. Moreover, they are mostly concerned with the economic dimension and, in most cases, tend to disregard the impact that water-energy loss may have on the quality of service, communication with the customers, social awareness, water quality and environment. This paper focuses on ...

  1. Chronic Loss of CA2 Transmission Leads to Hippocampal Hyperexcitability.

    Science.gov (United States)

    Boehringer, Roman; Polygalov, Denis; Huang, Arthur J Y; Middleton, Steven J; Robert, Vincent; Wintzer, Marie E; Piskorowski, Rebecca A; Chevaleyre, Vivien; McHugh, Thomas J

    2017-05-03

    Hippocampal CA2 pyramidal cells project into both the neighboring CA1 and CA3 subfields, leaving them well positioned to influence network physiology and information processing for memory and space. While recent work has suggested unique roles for CA2, including encoding position during immobility and generating ripple oscillations, an interventional examination of the integrative functions of these connections has yet to be reported. Here we demonstrate that CA2 recruits feedforward inhibition in CA3 and that chronic genetically engineered shutdown of CA2-pyramidal-cell synaptic transmission consequently results in increased excitability of the recurrent CA3 network. In behaving mice, this led to spatially triggered episodes of network-wide hyperexcitability during exploration accompanied by the emergence of high-frequency discharges during rest. These findings reveal CA2 as a regulator of network processing in hippocampus and suggest that CA2-mediated inhibition in CA3 plays a key role in establishing the dynamic excitatory and inhibitory balance required for proper network function. Copyright © 2017 Elsevier Inc. All rights reserved.

  2. Absorption-Edge-Modulated Transmission Spectra for Water Contaminant Monitoring

    Science.gov (United States)

    2016-03-31

    Naval Research Laboratory Washington, DC 20375-5320 NRL/MR/6390--16-9675 Absorption- Edge -Modulated Transmission Spectra for Water Contaminant...ABSTRACT c. THIS PAGE 18. NUMBER OF PAGES 17. LIMITATION OF ABSTRACT Absorption- Edge -Modulated Transmission Spectra for Water Contaminant Monitoring...contaminants, within a volume of sampled solution, requires sufficient sensitivity. The present study examines the sensitivity of absorption- edge

  3. Radiation loss of planar surface plasmon polaritons transmission lines at microwave frequencies.

    Science.gov (United States)

    Xu, Zhixia; Li, Shunli; Yin, Xiaoxing; Zhao, Hongxin; Liu, Leilei

    2017-07-21

    Radiation loss of a typical spoof surface plasmon polaritons (SSPPs) transmission line (TL) is investigated in this paper. A 325 mm-long SSPPs TL is designed and fabricated. Simulated results show that radiation loss contributes more to transmission loss than dielectric loss and conductor loss from 2 GHz to 10 GHz. Radiation loss of the SSPPs TL could be divided into two parts, one is caused by the input mode converter, and the other is caused by the corrugated metallic strip. This paper explains mechanisms of radiation loss from different parts, designs a loaded SSPPs TL with a series of resistors to absorb electromagnetic energy on corrugated metallic strip, and then discriminates radiation loss from the input mode converter, proposes the concept of average radiation length (ARL) to evaluate radiation loss from SSPPs of finite length, and concludes that radiation loss is mainly caused by corrugated structure of finite length at low frequency band and by the input mode converter at high frequency band. To suppress radiation loss, a mixed slow wave TL based on the combination of coplanar waveguides (CPWs) and SSPPs is presented. The designed structure, sample fabrication and experimental verification are discussed.

  4. Evaluation of damping loss factor of flat laminates by sound transmission

    Science.gov (United States)

    Parrinello, A.; Ghiringhelli, G. L.

    2018-06-01

    A novel approach to investigate and evaluate the damping loss factor of a planar multilayered structure is presented. A statistical analysis reveals the connection between the damping properties of the structure and the transmission of sound through the thickness of its laterally infinite counterpart. The obtained expression for the panel loss factor involves all the derivatives of the transmission and reflection coefficients of the layered structure with respect each layer damping. The properties of the fluid for which the sound transmission is evaluated are chosen to fulfil the hypotheses on the basis of the statistical formulation. A transfer matrix approach is used to compute the required transmission and reflection coefficients, making it possible to deal with structures having arbitrary stratifications of different layers and also granting high efficiency in a wide frequency range. Comparison with alternative formulations and measurements demonstrates the effectiveness of the proposed methodology.

  5. Validation of a Polyimide Foam Model for Use in Transmission Loss Applications

    Science.gov (United States)

    Hong, Kwanwoo; Bolton, J. Stuart; Cano, Roberto J.; Weiser, Erik S.; Jensen, Brian J.; Silcox, Rich; Howerton, Brian M.; Maxon, John; Wang, Tongan; Lorenzi, Tyler

    2010-01-01

    The work described in this paper was focused on the use of a new polyimide foam in a double wall sound transmission loss application. Recall that polyimide foams are functionally attractive, compared to polyurethane foams, for example, owing to their fire resistance. The foam considered here was found to have a flow resistivity that was too high for conventional acoustical applications, and as a result, it was processed by partial crushing to lower the flow resistivity into an acceptable range. Procedures for measuring the flow resistivity and Young s modulus of the material have been described, as was an inverse characterization procedure for estimating the remaining Biot parameters based on standing wave tube measurements of transmission loss and absorption coefficient. The inverse characterization was performed using a finite element model implementation of the Biot poro-elastic material theory. Those parameters were then used to predict the sound transmission loss of a double panel system lined with polyimide foam, and the predictions were compared with full-scale transmission loss measurements. The agreement between the two was reasonable, especially in the high and low frequency limits; however, it was found that the SEA model resulted in an under-prediction of the transmission loss in the mid-frequency range. Nonetheless, it was concluded that the performance of polyimide foam could be predicted using conventional poro-elastic material models and that polyimide foam may offer an attractive alternative to other double wall linings in certain situations: e.g., when fire resistance is a key issue. Future work will concentrate on reducing the density of the foam to values similar to those used in current aircraft sidewall treatments, and developing procedures to improve the performance of the foam in transmission loss applications.

  6. A Practical Radiosity Method for Predicting Transmission Loss in Urban Environments

    Directory of Open Access Journals (Sweden)

    Liang Ming

    2004-01-01

    Full Text Available The ability to predict transmission loss or field strength distribution is crucial for determining coverage in planning personal communication systems. This paper presents a practical method to accurately predict entire average transmission loss distribution in complicated urban environments. The method uses a 3D propagation model based on radiosity and a simplified city information database including surfaces of roads and building groups. Narrowband validation measurements with line-of-sight (LOS and non-line-of-sight (NLOS cases at 1800 MHz give excellent agreement in urban environments.

  7. MEASUREMENT AND ANALYSIS OF TRANSMISSION LOSSES IN THE SUPPLY SYSTEM OF ELECTRIFIED TRANSPORT

    Directory of Open Access Journals (Sweden)

    Mikołaj Bartłomiejczyk

    2016-11-01

    Full Text Available The issue of electric energy saving in public transport is currently becoming a key area of interest, a fact connected with both an increase in society’s environmental awareness and a rise in the prices of fuel and electricity. Electricity can be saved by reducing transmission losses in the supply system. The article presents a method of measurement and analysis of transmission losses in the supply system of electrified public transport on the example of trolleybus transport in Gdynia and Lublin in Poland.

  8. Mass and loss analysis of a space-type radiation cooled insulated DC transmission line

    International Nuclear Information System (INIS)

    Schwarze, g.E.

    1986-01-01

    As both the power levels and transmission distances increase such as for large future nuclear power systems, the transmission line becomes an important element in the power chain between the source and load bus. Thus, the transmission line's characteristics must be determined so that the effect of these characteristics on the total power system can be assessed. These design characteristics include the specific mass, percent power loss, size, voltage and power levels, and operating temperatures of the conductor and insulating materials. In a previous paper, the dc transmission line's characteristics of a noninsulated solid cylindrical conductor were determined. In that analysis the expression derived for the transmission line's mass only included the conductor mass and the operating temperature of the line was that of the conductor. In the analysis of this paper, a single layer of insulation is added to the solid cylindrical conductor. In this analysis the dependency of the dc transmission line's mass, loss, and size on the power and voltage levels, conductor and insulation surface temperatures, transmission distance, and conductor and insulation material properties is determined. This analysis can be extended to multi-layers of insulation but the complexity of the analysis increases as the number of layers increase

  9. Assessment of evaporative water loss from Dutch cities

    NARCIS (Netherlands)

    Jacobs, C.M.J.; Elbers, J.A.; Brolsma, R.; Hartogensis, O.K.; Moors, E.J.; Rodríguez-CarreteroMárquez, M.T.; Hove, van B.

    2015-01-01

    Reliable estimates of evaporative water loss are required to assess the urban water budget in support of division of water resources among various needs, including heat mitigation measures in cities relying on evaporative cooling. We report on urban evaporative water loss from Arnhem and Rotterdam

  10. Studying influence of two effective parameters on network losses in transmission expansion planning using DCGA

    International Nuclear Information System (INIS)

    Shayeghi, H.; Jalilzadeh, S.; Mahdavi, M.; Hadadian, H.

    2008-01-01

    Transmission network expansion planning (TNEP) is a basic part of power network planning that determines where, when and how many new transmission lines should be added to the network. Its task is to minimize the network construction and operational cost, while meeting imposed technical, economic and reliability constraints. Up till now, various methods have been proposed for solution of the static transmission network expansion planning (STNEP) problem. But, in all of them, the effect of two important parameters i.e., inflation rate and load growth factor on network losses has not been investigated. Thus, in this paper, STNEP is being studied considering the effect of inflation rate and load growth factor on the network losses in a transmission network with different voltage levels using a decimal codification genetic algorithm (DCGA). The effectiveness of the proposed idea is tested on the Garver's six-bus network. The results evaluation reveals that the inflation rate and load growth factor have important effect on the network losses and subsequent network arrangement. In addition, considering the effect of two above-mentioned parameters (inflation rate and load growth factor) in expansion planning of transmission networks with various line voltage levels is caused that the total expansion cost of the network (expansion costs and the operational cost) is calculated more exactly and therefore the network satisfies the requirements of delivering electric power more safely and reliably to load centers

  11. Prediction of the diffuse-field transmission loss of interior natural-ventilation openings and silencers.

    Science.gov (United States)

    Bibby, Chris; Hodgson, Murray

    2017-01-01

    The work reported here, part of a study on the performance and optimal design of interior natural-ventilation openings and silencers ("ventilators"), discusses the prediction of the acoustical performance of such ventilators, and the factors that affect it. A wave-based numerical approach-the finite-element method (FEM)-is applied. The development of a FEM technique for the prediction of ventilator diffuse-field transmission loss is presented. Model convergence is studied with respect to mesh, frequency-sampling and diffuse-field convergence. The modeling technique is validated by way of predictions and the comparison of them to analytical and experimental results. The transmission-loss performance of crosstalk silencers of four shapes, and the factors that affect it, are predicted and discussed. Performance increases with flow-path length for all silencer types. Adding elbows significantly increases high-frequency transmission loss, but does not increase overall silencer performance which is controlled by low-to-mid-frequency transmission loss.

  12. Impacts on investments, and transmission/distribution loss through power sector reforms

    International Nuclear Information System (INIS)

    Nagayama, Hiroaki

    2010-01-01

    This study analyses original panel data from 86 countries between 1985 and 2006. Econometric methods were used to identify the effects of different policy devices of power sector reforms on performance indicators (installed capacity per capita, transmission and distribution loss) in the countries analyzed. The research findings suggest that reform variables such as the entry of independent power producers (IPPs), unbundling of generation and transmission, establishment of regulatory agencies, and the introduction of a wholesale spot market are the driving forces of increasing generation capacity, as well as reducing transmission and distribution loss in the respective regions. In this study, we can assume that, firstly, different electric industry's reform policies/measures have different impacts on geographically and economically diverse countries. Secondly, a country's state of economic development has a different impact on policy effects of reforms. Thirdly, coexistent with independent regulatory agencies, reform policy becomes more powerful in realizing sector performances.

  13. Mode and climatic factors effect on energy losses in transient heat modes of transmission lines

    Science.gov (United States)

    Bigun, A. Ya; Sidorov, O. A.; Osipov, D. S.; Girshin, S. S.; Goryunov, V. N.; Petrova, E. V.

    2018-01-01

    Electrical energy losses increase in modern grids. The losses are connected with an increase in consumption. Existing models of electric power losses estimation considering climatic factors do not allow estimating the cable temperature in real time. Considering weather and mode factors in real time allows to meet effectively and safely the consumer’s needs to minimize energy losses during transmission, to use electric power equipment effectively. These factors increase an interest in the evaluation of the dynamic thermal mode of overhead transmission lines conductors. The article discusses an approximate analytic solution of the heat balance equation in the transient operation mode of overhead lines based on the least squares method. The accuracy of the results obtained is comparable with the results of solving the heat balance equation of transient thermal mode with the Runge-Kutt method. The analysis of mode and climatic factors effect on the cable temperature in a dynamic thermal mode is presented. The calculation of the maximum permissible current for variation of weather conditions is made. The average electric energy losses during the transient process are calculated with the change of wind, air temperature and solar radiation. The parameters having the greatest effect on the transmission capacity are identified.

  14. Losses at magnetic nulls in pulsed-power transmission line systems

    International Nuclear Information System (INIS)

    Mendel, C.W. Jr.; Pointon, T.D.; Savage, M.E.; Seidel, D.B.; Magne, I.; Vezinet, R.

    2006-01-01

    Pulsed-power systems operating in the terawatt regime must deal with large electron flows in vacuum transmission lines. In most parts of these transmission lines the electrons are constrained by the self-magnetic field to flow parallel to the conductors. In very low impedance systems, such as those used to drive Z-pinch radiation sources, the currents from multiple transmission lines are added together. This addition necessarily involves magnetic nulls that connect the positive and negative electrodes. The resultant local loss of magnetic insulation results in electron losses at the anode in the vicinity of the nulls. The lost current due to the magnetic null might or might not be appreciable. In some cases the lost current due to the null is not large, but is spatially localized, and may create a gas and plasma release from the anode that can lead to an excessive loss, and possibly to catastrophic damage to the hardware. In this paper we describe an analytic model that uses one geometric parameter (aside from straightforward hardware size measurements) that determines the loss to the anode, and the extent of the loss region when the driving source and load are known. The parameter can be calculated in terms of the magnetic field in the region of the null calculated when no electron flow is present. The model is compared to some experimental data, and to simulations of several different hardware geometries, including some cases with multiple nulls, and unbalanced feeds

  15. A method for the measurement of physiologic evaporative water loss.

    Science.gov (United States)

    1963-10-01

    The precise measurement of evaporative water loss is essential to an accurate evaluation of this avenue of heat loss in acute and chronic exposures to heat. In psychological studies, the quantitative measurement of palmar sweating plays an equally im...

  16. Economic evaluation of water loss saving due to the biological ...

    African Journals Online (AJOL)

    This paper focuses on water loss saving as the benefit derived from biological control of this plant between 1990 and 2013 at New Year's Dam, Alicedale, Eastern Cape, South Africa. Estimates of water loss due to evapotranspiration from water hyacinth vary significantly; therefore, the study used three different rates, high, ...

  17. General analytical approach for sound transmission loss analysis through a thick metamaterial plate

    International Nuclear Information System (INIS)

    Oudich, Mourad; Zhou, Xiaoming; Badreddine Assouar, M.

    2014-01-01

    We report theoretically and numerically on the sound transmission loss performance through a thick plate-type acoustic metamaterial made of spring-mass resonators attached to the surface of a homogeneous elastic plate. Two general analytical approaches based on plane wave expansion were developed to calculate both the sound transmission loss through the metamaterial plate (thick and thin) and its band structure. The first one can be applied to thick plate systems to study the sound transmission for any normal or oblique incident sound pressure. The second approach gives the metamaterial dispersion behavior to describe the vibrational motions of the plate, which helps to understand the physics behind sound radiation through air by the structure. Computed results show that high sound transmission loss up to 72 dB at 2 kHz is reached with a thick metamaterial plate while only 23 dB can be obtained for a simple homogeneous plate with the same thickness. Such plate-type acoustic metamaterial can be a very effective solution for high performance sound insulation and structural vibration shielding in the very low-frequency range

  18. General analytical approach for sound transmission loss analysis through a thick metamaterial plate

    Energy Technology Data Exchange (ETDEWEB)

    Oudich, Mourad; Zhou, Xiaoming; Badreddine Assouar, M., E-mail: Badreddine.Assouar@univ-lorraine.fr [CNRS, Institut Jean Lamour, Vandoeuvre-lès-Nancy F-54506 (France); Institut Jean Lamour, University of Lorraine, Boulevard des Aiguillettes, BP: 70239, 54506 Vandoeuvre-lès-Nancy (France)

    2014-11-21

    We report theoretically and numerically on the sound transmission loss performance through a thick plate-type acoustic metamaterial made of spring-mass resonators attached to the surface of a homogeneous elastic plate. Two general analytical approaches based on plane wave expansion were developed to calculate both the sound transmission loss through the metamaterial plate (thick and thin) and its band structure. The first one can be applied to thick plate systems to study the sound transmission for any normal or oblique incident sound pressure. The second approach gives the metamaterial dispersion behavior to describe the vibrational motions of the plate, which helps to understand the physics behind sound radiation through air by the structure. Computed results show that high sound transmission loss up to 72 dB at 2 kHz is reached with a thick metamaterial plate while only 23 dB can be obtained for a simple homogeneous plate with the same thickness. Such plate-type acoustic metamaterial can be a very effective solution for high performance sound insulation and structural vibration shielding in the very low-frequency range.

  19. Field-incidence noise transmission loss of general aviation aircraft double wall configurations

    Science.gov (United States)

    Grosveld, F. W.

    1984-01-01

    Theoretical formulations have been developed to describe the transmission of reverberant sound through an infinite, semi-infinite and a finite double panel structure. The model incorporates the fundamental resonance frequencies of each of the panels, the mass-air-mass resonances of the structure, the standing wave resonances in the cavity between the panels and finally the coincidence resonance regions, where the exciting sound pressure wave and flexural waves of each of the panels coincide. It is shown that phase cancellation effects of pressure waves reflected from the cavity boundaries back into the cavity allows the transmission loss of a finite double panel structure to be approximated by a finite double panel mounted in an infinite baffle having no cavity boundaries. Comparison of the theory with high quality transmission loss data yields good agreement in the mass-controlled frequency region. It is shown that the application of acoustic blankets to the double panel structure does not eliminate the mass-air-mass resonances if those occur at low frequencies. It is concluded that this frequency region of low noise transmission loss is a potential interior noise problem area for propeller driven aircraft having a double panel fuselage construction.

  20. Construction tolerances for low loss, dielectric coated, metallic waveguide for transmission optical radiation

    International Nuclear Information System (INIS)

    Sandweiss, J.

    1984-08-01

    The transmission of radiation, in a specific mode of interest for the IFELA, past a symmetric step in dielectric coating thickness has been calculated. The result shows that the transmission loss depends on the quantity (s/D) 2 and vanishes to first order in the ratio of the step s to the guide aperture D. With the reasonable assumption that this feature holds for all forms of surface imperfections, the attenuation length due to imperfections has been estimated. It is found that rms surface roughness of approx. 0.1 μ m leads to attenuation lengths of 25 km or greater

  1. Low-loss transmission band in photonic crystal waveguides with sharp cutoff at a frequency below the bandgap

    NARCIS (Netherlands)

    Krüger, A.C.; Zhang, M.; Groothoff, N.; Malureanu, R.; Kristensen, M.

    2011-01-01

    We present TE transmission measurements of photonic crystal waveguides with high hole radius to period ratio r/¿ = 0.388. This geometry introduces a unique low loss transmission band in addition to the traditional PhC guiding band and very sharp transmission edges for devices with a length of 50 µm

  2. Water Loss Management: Tools and Methods for Developing Countries

    OpenAIRE

    Mutikanga, H.E.

    2012-01-01

    Water utilities in developing countries are struggling to provide customers with a reliable level of service due to their peculiar water distribution characteristics including poorly zoned networks with irregular supply operating under restricted budgets. These unique conditions demand unique tools and methods for water loss control. Water loss management: Tools and Methods for Developing Countries provide a decision support toolbox (appropriate tools and methodologies) for assessing, quantif...

  3. A phylogenetic approach to total evaporative water loss in mammals.

    Science.gov (United States)

    Van Sant, Matthew J; Oufiero, Christopher E; Muñoz-Garcia, Agustí; Hammond, Kimberly A; Williams, Joseph B

    2012-01-01

    Maintaining appropriate water balance is a constant challenge for terrestrial mammals, and this problem can be exacerbated in desiccating environments. It has been proposed that natural selection has provided desert-dwelling mammals physiological mechanisms to reduce rates of total evaporative water loss. In this study, we evaluated the relationship between total evaporative water loss and body mass in mammals by using a recent phylogenetic hypothesis. We compared total evaporative water loss in 80 species of arid-zone mammals to that in 56 species that inhabit mesic regions, ranging in size from 4 g to 3,500 kg, to test the hypothesis that mammals from arid environments have lower rates of total evaporative water loss than mammals from mesic environments once phylogeny is taken into account. We found that arid species had lower rates of total evaporative water loss than mesic species when using a dichotomous variable to describe habitat (arid or mesic). We also found that total evaporative water loss was negatively correlated with the average maximum and minimum environmental temperature as well as the maximum vapor pressure deficit of the environment. Annual precipitation and the variable Q (a measure of habitat aridity) were positively correlated with total evaporative water loss. These results support the hypothesis that desert-dwelling mammals have lower rates of total evaporative water loss than mesic species after controlling for body mass and evolutionary relatedness regardless of whether categorical or continuous variables are used to describe habitat.

  4. Low-loss photonic crystal fibers for data transmission and their dispersion properties

    DEFF Research Database (Denmark)

    Nielsen, Martin Dybendal; Jacobsen, Christian; Mortensen, Niels Asger

    2004-01-01

    We report on a single-mode photonic crystal fiber with attenuation and effective area at 1550 nm of 0.48 dB/km and 130 µm2, respectively. This is, to our knowledge, the lowest loss reported for a PCF not made from VAD prepared silica and at the same time the largest effective area for a low......-loss (data transmission and show for the first time, both numerically and experimentally, how the group velocity dispersion is related to the mode field diameter....

  5. Research on Matrix-type Packet Loss Compensation Scheme for Wireless Video Transmission on Subway

    Directory of Open Access Journals (Sweden)

    Fan Qing-Wu

    2017-01-01

    Full Text Available As the mainstream wireless LAN technology, Wi-Fi can achieve fast data transfer. With the subway moving in a high speed, video data transmission between the metro and the ground is achieved through Wi-Fi technology. This paper aims at solving the Caton problem caused by switching packet loss in the process of playing real-time video on the train terminal, and proposes matrix-type packet loss compensation scheme. Finally, the feasibility of the scheme is verified by experiments.

  6. Model distinguishability and inference robustness in mechanisms of cholera transmission and loss of immunity

    OpenAIRE

    Lee, Elizabeth C.; Kelly, Michael R.; Ochocki, Brad M.; Akinwumi, Segun M.; Hamre, Karen E. S.; Tien, Joseph H.; Eisenberg, Marisa C.

    2016-01-01

    Mathematical models of cholera and waterborne disease vary widely in their structures, in terms of transmission pathways, loss of immunity, and other features. These differences may yield different predictions and parameter estimates from the same data. Given the increasing use of models to inform public health decision-making, it is important to assess distinguishability (whether models can be distinguished based on fit to data) and inference robustness (whether model inferences are robust t...

  7. Sound Transmission Loss Through a Corrugated-Core Sandwich Panel with Integrated Acoustic Resonators

    Science.gov (United States)

    Schiller, Noah H.; Allen, Albert R.; Zalewski, Bart F; Beck, Benjamin S.

    2014-01-01

    The goal of this study is to better understand the effect of structurally integrated resonators on the transmission loss of a sandwich panel. The sandwich panel has facesheets over a corrugated core, which creates long aligned chambers that run parallel to the facesheets. When ports are introduced through the facesheet, the long chambers within the core can be used as low-frequency acoustic resonators. By integrating the resonators within the structure they contribute to the static load bearing capability of the panel while also attenuating noise. An analytical model of a panel with embedded resonators is derived and compared with numerical simulations. Predictions show that acoustic resonators can significantly improve the transmission loss of the sandwich panel around the natural frequency of the resonators. In one configuration with 0.813 m long internal chambers, the diffuse field transmission loss is improved by more than 22 dB around 104 Hz. The benefit is achieved with no added mass or volume relative to the baseline structure. The embedded resonators are effective because they radiate sound out-of-phase with the structure. This results in destructive interference, which leads to less transmitted sound power.

  8. Biological control of schistosome transmission in flowing water habitats.

    Science.gov (United States)

    Jobin, W R; Laracuente, A

    1979-09-01

    Marisa cornuarietis was evaluated in Puerto Rico for control of schistosome transmission in flowing water. A population of Biomphalaria glabrata and their schistosome infections disappeared after introduction of 20,000 M. cornuarietis to an endemic stream, while in nearby untreated streams the B. glabrata population remained stable and the schistosome prevalence increased. This method cost U.S. $0.10 per capita for over a year of protection, 5%-10% of the cost of chemical control.

  9. ELECTRODYNAMICS OF TRANSMISSION AND LOSSES OF POWER IN THE DEVICES OF ELECTRIC TRACTION SYSTEMS

    Directory of Open Access Journals (Sweden)

    M. O. Kostin

    2014-01-01

    Full Text Available Purpose. Theoretical justification of the "field" approach (based on electromagnetic field to the transmission and losses of power in the devices of traction power supply systems and electric rolling stock. Methodology. The methods of electromagnetic field theory and, in particular, the theory and practice of electromagnetic energy transmission based on the concept of the Poynting vector and elements of the theory of propagation, reflection and refraction of plane electromagnetic waves were used. Findings. Theoretical studies of electromagnetic energy transmission from the traction substation to the electric rolling stock through dielectric (air surrounding traction network: between the contact wire and the rail were carried out. It is proposed strategic designing "squat" (low types of electric rolling stock. The components of electric energy flow through the roof of electric rolling stock and its frontal part of the body were estimated. This allows reliable etimating active power losses in electric traction system. To compensate the reactive power consumed by electric rolling stock, which is conditioned by standing waves, it is proposed (for extinction of the the last to develop and put in front of electric rolling stock the layer of particular environment with the necessary parameters. Originality. The "field" principle of the power transmission analysis and its losses arising in electric traction system was first proposed. The laws of motion of electromagnetic energy flows through the roof and the frontal part of the body of electric rolling stock were established. Practical value. An expression of the absolute value of the Poynting vector in the points of dielectric (air between the contact wire and the rail was obtained. This allows assessing the highest density of energy, which is transferred to the time unit and predicting the main dimensions of the unit of electric rolling stock. The energy indices of the roof of electric rolling stock

  10. AC losses in multilayer power transmission cables comprised of YBCO tapes

    International Nuclear Information System (INIS)

    Noji, H.

    2011-01-01

    I calculate AC properties in YBCO cable by an electric circuit model. The optimal helical pitches are determined by the calculation. The layer's current distribution is uniform on the optimal helical pitches. The calculation is useful as a first approximation of AC losses. AC losses in multilayer power transmission cables can be reduced by adjusting the helical winding pitch of each layer to make the layer's current distribution uniform. The optimum helical pitch can be estimated using an electric circuit (EC) model based on the expression that calculates the losses in the superconducting tapes composing the cable. It is known that the losses in a monolayer cable depend on the cable parameters (i.e., the gap between neighboring tapes, number of tapes N, diameter of the cable former and width of the tape). However, regarding Amemiya et al.'s measurement on the losses in monolayer cables, the numerical results of the losses calculated using the Norris formula for an isolated thin strip N times are close to the experimental results. Then, to determine the losses in a three-layer cable that Mukoyama et al. have reported, the losses are calculated by the EC model based on the Norris formula. The helical pitch of each layer is adjusted to make the layer's current distribution uniform in the cable reported by Mukoyama et al. The optimum helical pitches are calculated using the condition where the standard deviation of the layer currents is minimum, and the losses of the cable at the optimum helical pitches are calculated at 1 kA rms . By comparing the results of these calculations with the previously measured results, it was found that the mean error of the calculated values relative to the measured values is 23.7%, which indicates that the calculation using the EC model is useful as a first approximation.

  11. Use of Hydraulic Model for Water Loss Reduction

    OpenAIRE

    Mindaugas Rimeika; Anželika Jurkienė

    2016-01-01

    Hydraulic modeling is the modern way to apply world water engineering experience in every day practice. Hydraulic model is an effective tool in order to perform analysis of water supply system, optimization of its operation, assessment of system efficiency potential, evaluation of water network development, fire flow capabilities, energy saving opportunities and water loss reduction and ect. Hydraulic model shall include all possible engineering elements and devices allocated in a real water ...

  12. Significance of losses in water distribution systems in India

    OpenAIRE

    Raman, V.

    1983-01-01

    Effective management of water supply systems consists in supplying adequate quantities of clean water to the population. Detailed pilot studies of water distribution systems were carried out in 9 cities in India during 1971-81 to establish the feasibility of a programme of assessment, detection, and control of water losses from supply systems. A cost-benefit analysis was carried out. Water losses from mains and service pipes in the areas studied amounted to 20-35% of the total flow in the sys...

  13. Monitoring water loss form fresh concrete

    DEFF Research Database (Denmark)

    Jensen, Ole Mejlhede

    2006-01-01

    Desiccation of concrete before or during setting may lead to detrimental plastic shrinkage cracking in the concrete surface zone. Cracking due to plastic shrinkage is a major technological problem for any concrete, however, modern high-performance concretes are especially susceptible to this...... determination of the evaporation loss from hardening concrete and thus better possibility for preventing curing problems, including detrimental crack damage due to plastic shrinkage....

  14. Heat losses through pipe connections in hot water stores

    DEFF Research Database (Denmark)

    Andersen, Elsa; Fan, Jianhua; Furbo, Simon

    2007-01-01

    The heat loss from pipe connections at the top of hot water storage tanks with and without a heat trap is investigated theoretically and compared to similar experimental investigations. Computational Fluid Dynamics (CFD) is used for the theoretical analysis. The investigations show that the heat...... loss from an ideally insulated pipe connected to the top of a hot water tank is mainly due to a natural convection flow in the pipe, that the heat loss coefficient of pipes connected to the top of a hot water tank is high, and that a heat trap can reduce the heat loss coefficient significantly. Further......, calculations show that the yearly thermal performance of solar domestic hot water systems is strongly reduced if the hot water tank has a thermal bridge located at the top of the tank....

  15. Optimizing real power loss and voltage stability limit of a large transmission network using firefly algorithm

    Directory of Open Access Journals (Sweden)

    P. Balachennaiah

    2016-06-01

    Full Text Available This paper proposes a Firefly algorithm based technique to optimize the control variables for simultaneous optimization of real power loss and voltage stability limit of the transmission system. Mathematically, this issue can be formulated as nonlinear equality and inequality constrained optimization problem with an objective function integrating both real power loss and voltage stability limit. Transformers taps, unified power flow controller and its parameters have been included as control variables in the problem formulation. The effectiveness of the proposed algorithm has been tested on New England 39-bus system. Simulation results obtained with the proposed algorithm are compared with the real coded genetic algorithm for single objective of real power loss minimization and multi-objective of real power loss minimization and voltage stability limit maximization. Also, a classical optimization method known as interior point successive linear programming technique is considered here to compare the results of firefly algorithm for single objective of real power loss minimization. Simulation results confirm the potentiality of the proposed algorithm in solving optimization problems.

  16. Impact of distributed generators on the power loss and voltage profile of sub-transmission network

    Directory of Open Access Journals (Sweden)

    A.S.O. Ogunjuyigbe

    2016-05-01

    Full Text Available This paper presents the impact of distributed generator (DG on the power loss and voltage profile of sub-transmission network at different penetration levels (PLs. The various DG technologies are modeled based on their electrical output characteristics. Voltage profile index which allows a single value to represent how well the voltage matches the ideal value is developed. The index allows a fair comparison of the voltage profile obtained from different scenarios. The extent to which DGs affect power losses and voltage profile depend on the type of DG technology, PL and the location in which the DG is connected to the grid. The integration of DGs reduces power losses on the network, however, as the PL increases, the power losses begin to increase. A PL of 50–75% is achieved on 69 kV voltage level and 25–50% penetration on 13.8 kV voltage level without an increase in the power loss. Also more DG can be integrated into the network at point of common connection of higher voltage level compared to the low voltage level.

  17. Automatic Assessment of Acquisition and Transmission Losses in Indian Remote Sensing Satellite Data

    Science.gov (United States)

    Roy, D.; Purna Kumari, B.; Manju Sarma, M.; Aparna, N.; Gopal Krishna, B.

    2016-06-01

    The quality of Remote Sensing data is an important parameter that defines the extent of its usability in various applications. The data from Remote Sensing satellites is received as raw data frames at the ground station. This data may be corrupted with data losses due to interferences during data transmission, data acquisition and sensor anomalies. Thus it is important to assess the quality of the raw data before product generation for early anomaly detection, faster corrective actions and product rejection minimization. Manual screening of raw images is a time consuming process and not very accurate. In this paper, an automated process for identification and quantification of losses in raw data like pixel drop out, line loss and data loss due to sensor anomalies is discussed. Quality assessment of raw scenes based on these losses is also explained. This process is introduced in the data pre-processing stage and gives crucial data quality information to users at the time of browsing data for product ordering. It has also improved the product generation workflow by enabling faster and more accurate quality estimation.

  18. Numerical study of electron-leakage power loss in a tri-plate transmission line

    International Nuclear Information System (INIS)

    Barker, R.J.; Goldstein, S.A.

    1982-01-01

    Numerical simulations have been conducted using NRL's DIODE2D computer code to model the steady-state behavior of electron flow in a radial diode and in its adjacent tri-plate transmission line (TTL). Particular attention was paid to the magnitude of the electron current flowing from the cathode to the anode surface in the TTL. A quantitative value for this effective power loss is given. The electron current is restricted mainly to the transition region in the TTL into which there is seepage of the B/sub z/ that is imposed in the diode gap. This finding highlights the importance of that region to diode designers

  19. Percolation Model of Sensory Transmission and Loss of Consciousness Under General Anesthesia

    Science.gov (United States)

    Zhou, David W.; Mowrey, David D.; Tang, Pei; Xu, Yan

    2015-09-01

    Neurons communicate with each other dynamically; how such communications lead to consciousness remains unclear. Here, we present a theoretical model to understand the dynamic nature of sensory activity and information integration in a hierarchical network, in which edges are stochastically defined by a single parameter p representing the percolation probability of information transmission. We validate the model by comparing the transmitted and original signal distributions, and we show that a basic version of this model can reproduce key spectral features clinically observed in electroencephalographic recordings of transitions from conscious to unconscious brain activities during general anesthesia. As p decreases, a steep divergence of the transmitted signal from the original was observed, along with a loss of signal synchrony and a sharp increase in information entropy in a critical manner; this resembles the precipitous loss of consciousness during anesthesia. The model offers mechanistic insights into the emergence of information integration from a stochastic process, laying the foundation for understanding the origin of cognition.

  20. Significance of losses in water distribution systems in India.

    Science.gov (United States)

    Raman, V

    1983-01-01

    Effective management of water supply systems consists in supplying adequate quantities of clean water to the population. Detailed pilot studies of water distribution systems were carried out in 9 cities in India during 1971-81 to establish the feasibility of a programme of assessment, detection, and control of water losses from supply systems. A cost-benefit analysis was carried out. Water losses from mains and service pipes in the areas studied amounted to 20-35% of the total flow in the system. At a conservative estimate, the national loss of processed water through leaks in the water distribution systems amounts to 10(12) litres per year, which is equivalent to 500 million rupees.It is possible to bring down the water losses in the pipe mains to 3-5% of the total flow, and the cost incurred on the control programme can be recovered in 6-18 months. Appropriate conservation measures will help in achieving the goals of the International Water Supply and Sanitation Decade to provide clean water for all.

  1. Model distinguishability and inference robustness in mechanisms of cholera transmission and loss of immunity.

    Science.gov (United States)

    Lee, Elizabeth C; Kelly, Michael R; Ochocki, Brad M; Akinwumi, Segun M; Hamre, Karen E S; Tien, Joseph H; Eisenberg, Marisa C

    2017-05-07

    Mathematical models of cholera and waterborne disease vary widely in their structures, in terms of transmission pathways, loss of immunity, and a range of other features. These differences can affect model dynamics, with different models potentially yielding different predictions and parameter estimates from the same data. Given the increasing use of mathematical models to inform public health decision-making, it is important to assess model distinguishability (whether models can be distinguished based on fit to data) and inference robustness (whether inferences from the model are robust to realistic variations in model structure). In this paper, we examined the effects of uncertainty in model structure in the context of epidemic cholera, testing a range of models with differences in transmission and loss of immunity structure, based on known features of cholera epidemiology. We fit these models to simulated epidemic and long-term data, as well as data from the 2006 Angola epidemic. We evaluated model distinguishability based on fit to data, and whether the parameter values, model behavior, and forecasting ability can accurately be inferred from incidence data. In general, all models were able to successfully fit to all data sets, both real and simulated, regardless of whether the model generating the simulated data matched the fitted model. However, in the long-term data, the best model fits were achieved when the loss of immunity structures matched those of the model that simulated the data. Two parameters, one representing person-to-person transmission and the other representing the reporting rate, were accurately estimated across all models, while the remaining parameters showed broad variation across the different models and data sets. The basic reproduction number (R 0 ) was often poorly estimated even using the correct model, due to practical unidentifiability issues in the waterborne transmission pathway which were consistent across all models. Forecasting

  2. Transmission loss of orthogonally rib-stiffened double-panel structures with cavity absorption.

    Science.gov (United States)

    Xin, F X; Lu, T J

    2011-04-01

    The transmission loss of sound through infinite orthogonally rib-stiffened double-panel structures having cavity-filling fibrous sound absorptive materials is theoretically investigated. The propagation of sound across the fibrous material is characterized using an equivalent fluid model, and the motions of the rib-stiffeners are described by including all possible vibrations, i.e., flexural displacements, bending, and torsional rotations. The effects of fluid-structure coupling are account for by enforcing velocity continuity conditions at fluid-panel interfaces. By taking full advantage of the periodic nature of the double-panel, the space-harmonic approach and virtual work principle are applied to solve the sets of resultant governing equations, which are eventually truncated as a finite system of simultaneous algebraic equations and numerically solved insofar as the solution converges. To validate the proposed model, a comparison between the present model predictions and existing numerical and experimental results for a simplified version of the double-panel structure is carried out, with overall agreement achieved. The model is subsequently employed to explore the influence of the fluid-structure coupling between fluid in the cavity and the two panels on sound transmission across the orthogonally rib-stiffened double-panel structure. Obtained results demonstrate that this fluid-structure coupling affects significantly sound transmission loss (STL) at low frequencies and cannot be ignored when the rib-stiffeners are sparsely distributed. As a highlight of this research, an integrated optimal algorithm toward lightweight, high-stiffness and superior sound insulation capability is proposed, based on which a preliminary optimal design of the double-panel structure is performed.

  3. Growth of optical transmission loss at 850 nm in silica core optical fibers during fission reactor irradiation

    International Nuclear Information System (INIS)

    Shikama, T.; Narui, M.; Sagawa, T.

    1998-01-01

    Pure, OH-doped and F-doped silica core optical fibers were irradiated in a fission reactor at 400±10 K using an electric heater at a reactor power greater than 10 MW (20% of the full power). The temperature was not controlled well at the early stage of the reactor startup, when the temperature was about 320-340 K. The optical fibers were irradiated with a fast neutron (E>1 MeV) flux of 3.2 x 10 17 n/cm 2 s and a gamma dose rate of 3 x 10 3 Gy/s for 527 h. Optical transmission loss at 850 nm was measured in situ during irradiation. A prompt increase in optical transmission loss was observed as irradiation started, which was probably due to dynamic irradiation effects caused by short-lived and transient defects and is probably recoverable when irradiation ceases. After the prompt increase in optical transmission loss, a so-called radiation hardening was observed in fibers containing OH. Radiation hardening was also observed in 900 ppm OH-doped fiber at the second startup. The optical transmission loss increased linearly with irradiation dose, denoted as the accumulated loss, which we believe is due to irradiation-induced long-lived defects. Accumulated loss dominates radiation-induced optical transmission loss in a fission reactor irradiation. (orig.)

  4. WATER LOSS OF KOKA RESERVOIR, ETHIOPIA: COMMENTS ON

    African Journals Online (AJOL)

    to be used for Awash River simulation model. Key words/phrases: Ethiopia, Koka Reservoir water loss, leakage rate, subsurface inflow, water balance. INTRODUCTION. Koka Dam was built on Awash River, Ethiopia, in 1960 for hydropower and irrigation purposes. It is located at 8°24'N latitude and 39°05'E longitude (Fig.

  5. Water loss from terrestrial planets with CO2-rich atmospheres

    International Nuclear Information System (INIS)

    Wordsworth, R. D.; Pierrehumbert, R. T.

    2013-01-01

    Water photolysis and hydrogen loss from the upper atmospheres of terrestrial planets is of fundamental importance to climate evolution but remains poorly understood in general. Here we present a range of calculations we performed to study the dependence of water loss rates from terrestrial planets on a range of atmospheric and external parameters. We show that CO 2 can only cause significant water loss by increasing surface temperatures over a narrow range of conditions, with cooling of the middle and upper atmosphere acting as a bottleneck on escape in other circumstances. Around G-stars, efficient loss only occurs on planets with intermediate CO 2 atmospheric partial pressures (0.1-1 bar) that receive a net flux close to the critical runaway greenhouse limit. Because G-star total luminosity increases with time but X-ray and ultraviolet/ultravoilet luminosity decreases, this places strong limits on water loss for planets like Earth. In contrast, for a CO 2 -rich early Venus, diffusion limits on water loss are only important if clouds caused strong cooling, implying that scenarios where the planet never had surface liquid water are indeed plausible. Around M-stars, water loss is primarily a function of orbital distance, with planets that absorb less flux than ∼270 W m –2 (global mean) unlikely to lose more than one Earth ocean of H 2 O over their lifetimes unless they lose all their atmospheric N 2 /CO 2 early on. Because of the variability of H 2 O delivery during accretion, our results suggest that many 'Earth-like' exoplanets in the habitable zone may have ocean-covered surfaces, stable CO 2 /H 2 O-rich atmospheres, and high mean surface temperatures.

  6. Multi-criteria decision analysis : A strategic planning tool for water loss management

    NARCIS (Netherlands)

    Mutikanga, H.E.; Sharma, S.K.; Vairavamoorthy, K.

    2011-01-01

    Water utilities particularly in the developing countries continue to operate with considerable inefficiencies in terms of water and revenue losses. With increasing water demand and scarcity, utilities require effective strategies for optimum use of available water resources. Diverse water loss

  7. Loss of Water to Space from Mars: Processes and Implications

    Science.gov (United States)

    Kass, D. M.

    2001-12-01

    One of the major sinks for water on Mars is the loss to space. This occurs via a complex series of processes that transport the individual atoms to the upper atmosphere, where several escape mechanisms remove them. Hydrogen and deuterium are lost primarily by Jeans escape. Non-thermal processes also remove H and D, but are only important in determining D loss at solar minimum under modern conditions. The present H loss rate is equivalent to the loss of 10-3~pr-\\micron~yr-1 of water. The loss of oxygen is more complicated. The three main processes are indirect (or ionospheric) sputtering, solar wind pickup of O+, and O2+ dissociative recombination. Their relative importance has varied over the history of Mars. The combined effect of the O loss processes is to remove a ~ 50~m global layer of water over the last 3.5 Gyr. Based on photochemical modeling, the loss of oxygen and hydrogen are balanced (over geological timescales) by a feedback process. During the early history of Mars, impact erosion and hydrodynamic blow-off may have removed significant water. But, it is difficult to estimate their quantitative effects. The transport of individual H, D and O atoms to the exosphere where they can escape is not completely understood. It occurs primarily via intermediate species, H2, HD, O2 and CO2. The H2 and HD are formed by photolysis of water and the odd hydrogen photochemistry. One open issue is the mechanism regulating the partitioning of D between HDO and HD (which controls the supply of D available for escape from the exosphere). The various loss processes isotopically enrich Martian water since the exospheric escape source region is depleted. Jeans escape and the transport from the lower atmosphere further fractionate hydrogen, the most useful isotopic system. Based on recent observations, the D/H fractionation factor, F ~ 0.02. Measurements of atmospheric water vapor indicate it is enriched in deuterium, with a D/H ratio ~ 5 times the terrestrial value. Since

  8. Water Loss Reduction as the Basis of Good Water Supply Companies’ Management

    Directory of Open Access Journals (Sweden)

    Ociepa-Kubicka Agnieszka

    2017-01-01

    Full Text Available Companies using water distribution systems to reduce the operating costs and increase the reliability of water supply systems, as well as to protect disposable water resources, must search for ways to reduce water losses. The article points out the economic and environmental aspects of water losses. The possibilities of using international water loss assessment standards have been analysed. The reflections presented in the paper refer to the current trends and world standards in the field of water distribution systems management. The article presents the results and analysis of water losses for the water supply network operated by the Water Supply and Sewerage Company in Gliwice (Przedsiębiorstwo Wodociągów i Kanalizacji w Gliwicach, PWiK. The losses were determined on the basis of numerous indicators and compared with other distribution systems. At present, most indicators of water loss are at a very good or good level. The Infrastructure Leakage Index (ILI, as one of the most reliable loss indicators for the surveyed distribution system, assumed values from 3.33 in 2012 to 2.06 in 2015. The recent drop in ILI values indicates the effectiveness of the Company's strategy for water leakage reduction. The success comprises a number of undertakings, such as ongoing monitoring, pressure reduction and stabilisation, repairs and replacement of the most emergency wires.

  9. Water Loss Reduction as the Basis of Good Water Supply Companies' Management

    Science.gov (United States)

    Ociepa-Kubicka, Agnieszka; Wilczak, Krzysztof

    2017-10-01

    Companies using water distribution systems to reduce the operating costs and increase the reliability of water supply systems, as well as to protect disposable water resources, must search for ways to reduce water losses. The article points out the economic and environmental aspects of water losses. The possibilities of using international water loss assessment standards have been analysed. The reflections presented in the paper refer to the current trends and world standards in the field of water distribution systems management. The article presents the results and analysis of water losses for the water supply network operated by the Water Supply and Sewerage Company in Gliwice (Przedsiębiorstwo Wodociągów i Kanalizacji w Gliwicach, PWiK). The losses were determined on the basis of numerous indicators and compared with other distribution systems. At present, most indicators of water loss are at a very good or good level. The Infrastructure Leakage Index (ILI), as one of the most reliable loss indicators for the surveyed distribution system, assumed values from 3.33 in 2012 to 2.06 in 2015. The recent drop in ILI values indicates the effectiveness of the Company's strategy for water leakage reduction. The success comprises a number of undertakings, such as ongoing monitoring, pressure reduction and stabilisation, repairs and replacement of the most emergency wires.

  10. Prediction of sound transmission loss through multilayered panels by using Gaussian distribution of directional incident energy

    Science.gov (United States)

    Kang; Ih; Kim; Kim

    2000-03-01

    In this study, a new prediction method is suggested for sound transmission loss (STL) of multilayered panels of infinite extent. Conventional methods such as random or field incidence approach often given significant discrepancies in predicting STL of multilayered panels when compared with the experiments. In this paper, appropriate directional distributions of incident energy to predict the STL of multilayered panels are proposed. In order to find a weighting function to represent the directional distribution of incident energy on the wall in a reverberation chamber, numerical simulations by using a ray-tracing technique are carried out. Simulation results reveal that the directional distribution can be approximately expressed by the Gaussian distribution function in terms of the angle of incidence. The Gaussian function is applied to predict the STL of various multilayered panel configurations as well as single panels. The compared results between the measurement and the prediction show good agreements, which validate the proposed Gaussian function approach.

  11. Optimization of Coding of AR Sources for Transmission Across Channels with Loss

    DEFF Research Database (Denmark)

    Arildsen, Thomas

    Source coding concerns the representation of information in a source signal using as few bits as possible. In the case of lossy source coding, it is the encoding of a source signal using the fewest possible bits at a given distortion or, at the lowest possible distortion given a specified bit rate....... Channel coding is usually applied in combination with source coding to ensure reliable transmission of the (source coded) information at the maximal rate across a channel given the properties of this channel. In this thesis, we consider the coding of auto-regressive (AR) sources which are sources that can...... compared to the case where the encoder is unaware of channel loss. We finally provide an extensive overview of cross-layer communication issues which are important to consider due to the fact that the proposed algorithm interacts with the source coding and exploits channel-related information typically...

  12. A new global particle swarm optimization for the economic emission dispatch with or without transmission losses

    International Nuclear Information System (INIS)

    Zou, Dexuan; Li, Steven; Li, Zongyan; Kong, Xiangyong

    2017-01-01

    Highlights: • A new global particle swarm optimization (NGPSO) is proposed. • NGPSO has strong convergence and desirable accuracy. • NGPSO is used to handle the economic emission dispatch with or without transmission losses. • The equality constraint can be satisfied by solving a quadratic equation. • The inequality constraints can be satisfied by using penalty function method. - Abstract: A new global particle swarm optimization (NGPSO) algorithm is proposed to solve the economic emission dispatch (EED) problems in this paper. NGPSO is different from the traditional particle swarm optimization (PSO) algorithm in two aspects. First, NGPSO uses a new position updating equation which relies on the global best particle to guide the searching activities of all particles. Second, it uses the randomization based on the uniform distribution to slightly disturb the flight trajectories of particles during the late evolutionary process. The two steps enable NGPSO to effectively execute a number of global searches, and thus they increase the chance of exploring promising solution space, and reduce the probabilities of getting trapped into local optima for all particles. On the other hand, the two objective functions of EED are normalized separately according to all candidate solutions, and then they are incorporated into one single objective function. The transformation steps are very helpful in eliminating the difference caused by the different dimensions of the two functions, and thus they strike a balance between the fuel cost and emission. In addition, a simple and common penalty function method is employed to facilitate the satisfactions of EED’s constraints. Based on these improvements in PSO, objective functions and constraints handling, high-quality solutions can be obtained for EED problems. Five examples are chosen to testify the performance of three improved PSOs on solving EED problems with or without transmission losses. Experimental results show that

  13. Effect of air flow, panel curvature, and internal pressurization on field-incidence transmission loss

    Science.gov (United States)

    Koval, L. R.

    1976-01-01

    In the context of sound transmission through aircraft fuselage panels, equations for the field-incidence transmission loss (TL) of a single-walled panel are derived that include the effects of external air flow, panel curvature, and internal fuselage pressurization. Flow is shown to provide a modest increase in TL that is uniform with frequency up to the critical frequency. The increase is about 2 dB at Mach number M = 0.5, and about 3.5 dB at M = 1. Above the critical frequency where TL is damping controlled, the increase can be slightly larger at certain frequencies. Curvature is found to stiffen the panel, thereby increasing the TL at low frequencies, but also to introduce a dip at the 'ring frequency' of a full cylinder having the same radius as the panel. Pressurization appears to produce a slight decrease in TL throughout the frequency range, and also slightly shifts the dips at the critical frequency and at the ring frequency.

  14. Normal Incidence of Sound Transmission Loss of a Double-Leaf Partition Inserted with a Microperforated Panel

    Directory of Open Access Journals (Sweden)

    A. Putra

    2013-01-01

    Full Text Available A double-leaf partition in engineering structures has been widely applied for its advantages, that is, in terms of its mechanical strength as well as its lightweight property. In noise control, the double-leaf also serves as an effective noise barrier. Unfortunately at low frequency, the sound transmission loss reduces significantly due to the coupling between the panels and the air between them. This paper studies the effect of a microperforated panel (MPP inserted inside a double-leaf partition on the sound transmission loss performance of the system. The MPP insertion is proposed to provide a hygienic double-leaf noise insulator replacing the classical abrasive porous materials between the panels. It is found that the transmission loss improves at the troublesome mass-air-mass resonant frequency if the MPP is located closer to the solid panel. The mathematical model is derived for normal incidence of acoustic loading.

  15. The effect on the transmission loss of a double wall panel of using helium gas in the gap

    Science.gov (United States)

    Atwal, M. S.; Crocker, M. J.

    The possibility of increasing the sound-power transmission loss of a double panel by using helium gas in the gap is investigated. The transmission loss of a panel is defined as ten times the common logarithm of the ratio of the sound power incident on the panel to the sound power transmitted to the space on the other side of the panel. The work is associated with extensive research being done to develop new techniques for predicting the interior noise levels on board high-speed advanced turboprop aircraft and reducing the noise levels with a minimum weight penalty. Helium gas was chosen for its inert properties and its low impedance compared with air. With helium in the gap, the impedance mismatch experienced by the sound wave will be greater than that with air in the gap. It is seen that helium gas in the gap increases the transmission loss of the double panel over a wide range of frequencies.

  16. Study of the effect of finite extent on sound transmission loss of single panel using a waveguide model

    OpenAIRE

    Prasetiyo , Iwan; Thompson , David

    2012-01-01

    International audience; The sound transmission loss (STL) of a panel is often estimated using an infinite plate model. However, some discrepancies are found between these predicted results and experimental ones. One of the sources of such discrepancies corresponds to the finite extent that is naturally found in real structures. In the present study an analytical waveguide model of sound transmission is used to study the effect of finite dimensions in one direction for a panel which is long in...

  17. Thermoregulation and evaporative water loss in growing African ...

    African Journals Online (AJOL)

    Kalahari Gemsbok National Park, Private Bag X5890, Upington, 8800 Republic of South AfricaWith an increase in mass, weaned giant rat pups Cricetomys gambianus, showed a corresponding decline in mass specific metabolism, conductance and evaporative water loss. The decline in metabolism correlates better with ...

  18. Water-hydraulic power transmission for offshore wind farms

    NARCIS (Netherlands)

    Diepeveen, N.F.B.; Jarquin Laguna, A.; Kempenaar, A.S.

    2012-01-01

    The current state of the art of offshore wind turbine power transmission technology is expensive, heavy and maintenance intensive. The Delft Offshore Turbine project considers a radically new concept for power transmission in an offshore wind farm: using seawater as power transmission medium. For

  19. Low-loss transmission band in photonic crystal waveguides with sharp cutoff at a frequency below the bandgap

    DEFF Research Database (Denmark)

    Krüger, Asger Christian; Zhang, Min; Groothoff, Nathaniel

    2011-01-01

    We present TE transmission measurements of photonic crystal waveguides with high hole radius to period ratio r/Λ=0.388. This geometry introduces a unique low loss transmission band in addition to the traditional PhC guiding band and very sharp transmission edges for devices with a length of 50 μm...... or longer. Finite difference time domain and plane wave expansion simulations confirm the results and show that the sharpness of the cutoffs can be explained by the spectral shape of the guiding mode in the band diagram....

  20. Evaluation of seasonality on total water intake, water loss and water balance in the general population in Greece.

    Science.gov (United States)

    Malisova, O; Bountziouka, V; Panagiotakos, D Β; Zampelas, A; Kapsokefalou, M

    2013-07-01

    Water balance is achieved when water intake from solid and fluid foods and drinking water meets water losses, mainly in sweat, urine and faeces. Seasonality, particularly in Mediterranean countries that have a hot summer, may affect water loss and consequently water balance. Water balance has not been estimated before on a population level and the effect of seasonality has not been evaluated. The present study aimed to compare water balance, intake and loss in summer and winter in a sample of the general population in Greece. The Water Balance Questionnaire (WBQ) was used to evaluate water balance, estimating water intake and loss in summer (n = 480) and in winter (n = 412) on a stratified sample of the general population in Athens, Greece. In winter, mean (SD) water balance was -63 (1478) mL/day(-1) , mean (SD)water intake was 2892 (987) mL/day(-1) and mean (quartile range) water loss was 2637 (1810-3922) mL/day(-1) . In summer, mean (SD) water balance was -58 (2150) mL/day(-1) , mean (SD) water intake was 3875 (1373) mL/day(-1) and mean (quartile range) water loss was 3635 (2365-5258) mL/day(-1) . Water balance did not differ between summer and winter (P = 0.96); however, the data distribution was different; in summer, approximately 8% more participants were falling in the low and high water balance categories. Differences in water intake from different sources were identified (P balance in summer and winter was not different. However, water intake and loss were approximately 40% higher in summer than in winter. More people were falling in the low and high water balance categories in summer when comparing the distribution on water balance in winter. © 2013 The Authors Journal of Human Nutrition and Dietetics © 2013 The British Dietetic Association Ltd.

  1. Virtual water trade and time scales for loss of water sustainability: a comparative regional analysis.

    Science.gov (United States)

    Goswami, Prashant; Nishad, Shiv Narayan

    2015-03-20

    Assessment and policy design for sustainability in primary resources like arable land and water need to adopt long-term perspective; even small but persistent effects like net export of water may influence sustainability through irreversible losses. With growing consumption, this virtual water trade has become an important element in the water sustainability of a nation. We estimate and contrast the virtual (embedded) water trades of two populous nations, India and China, to present certain quantitative measures and time scales. Estimates show that export of embedded water alone can lead to loss of water sustainability. With the current rate of net export of water (embedded) in the end products, India is poised to lose its entire available water in less than 1000 years; much shorter time scales are implied in terms of water for production. The two cases contrast and exemplify sustainable and non-sustainable virtual water trade in long term perspective.

  2. Impact of palmitic acid coating on the water uptake and loss of ammonium sulfate particles

    Directory of Open Access Journals (Sweden)

    R. M. Garland

    2005-01-01

    Full Text Available While water insoluble organics are prevalent in the atmosphere, it is not clear how the presence of such species alters the chemical and physical properties of atmospheric aerosols. Here we use a combination of FTIR spectroscopy, Transmission Electron Microscopy (TEM and Aerosol Mass Spectrometry (AMS to characterize ammonium sulfate particles coated with palmitic acid. Coated aerosols were generated by atomizing pure ammonium sulfate, mixing the particles with a heated flow of nitrogen with palmitic acid vapor, and then flowing the mixture through an in-line oven to create internally mixed particles. The mixing state of the particles was probed using the AMS data and images from the TEM. Both of these probes suggest that the particles were internally mixed. Water uptake by the mixed particles was then probed at 273 K. It was found that for ammonium sulfate containing ~20 wt% palmitic acid the deliquescence relative humidity (DRH was the same as for pure ammonium sulfate (80±3% RH. For particles with ~50 wt% palmitic acid however, the mixed particles began to take up water at relative humidities as low at 69% and continued to slowly take up water to 85% RH without fully deliquescing. In addition to studies of water uptake, water loss was also investigated. Here coatings of up to 50 wt% had no impact on the efflorescence relative humidity. These studies suggest that even if insoluble substances coat salt particles in the atmosphere, there may be relatively little effect on the resulting water uptake and loss.

  3. A new algorithm for optimum voltage and reactive power control for minimizing transmission lines losses

    International Nuclear Information System (INIS)

    Ghoudjehbaklou, H.; Danai, B.

    2001-01-01

    Reactive power dispatch for voltage profile modification has been of interest to power utilities. Usually local bus voltages can be altered by changing generator voltages, reactive shunts, ULTC transformers and SVCs. Determination of optimum values for control parameters, however, is not simple for modern power system networks. Heuristic and rather intelligent algorithms have to be sought. In this paper a new algorithm is proposed that is based on a variant of a genetic algorithm combined with simulated annealing updates. In this algorithm a fuzzy multi-objective a approach is used for the fitness function of the genetic algorithm. This fuzzy multi-objective function can efficiently modify the voltage profile in order to minimize transmission lines losses, thus reducing the operating costs. The reason for such a combination is to utilize the best characteristics of each method and overcome their deficiencies. The proposed algorithm is much faster than the classical genetic algorithm and cna be easily integrated into existing power utilities software. The proposed algorithm is tested on an actual system model of 1284 buses, 799 lines, 1175 fixed and ULTC transformers, 86 generators, 181 controllable shunts and 425 loads

  4. Analytical and experimental investigation on transmission loss of clamped double panels: implication of boundary effects.

    Science.gov (United States)

    Xin, F X; Lu, T J

    2009-03-01

    The air-borne sound insulation performance of a rectangular double-panel partition clamp mounted on an infinite acoustic rigid baffle is investigated both analytically and experimentally and compared with that of a simply supported one. With the clamped (or simply supported) boundary accounted for by using the method of modal function, a double series solution for the sound transmission loss (STL) of the structure is obtained by employing the weighted residual (Galerkin) method. Experimental measurements with Al double-panel partitions having air cavity are subsequently carried out to validate the theoretical model for both types of the boundary condition, and good overall agreement is achieved. A consistency check of the two different models (based separately on clamped modal function and simply supported modal function) is performed by extending the panel dimensions to infinite where no boundaries exist. The significant discrepancies between the two different boundary conditions are demonstrated in terms of the STL versus frequency plots as well as the panel deflection mode shapes.

  5. Auralization of vibroacoustic models in engineering using Wave Field Synthesis: Application to plates and transmission loss

    Science.gov (United States)

    Bolduc, A.; Gauthier, P.-A.; Berry, A.

    2017-12-01

    While perceptual evaluation and sound quality testing with jury are now recognized as essential parts of acoustical product development, they are rarely implemented with spatial sound field reproduction. Instead, monophonic, stereophonic or binaural presentations are used. This paper investigates the workability and interest of a method to use complete vibroacoustic engineering models for auralization based on 2.5D Wave Field Synthesis (WFS). This method is proposed in order that spatial characteristics such as directivity patterns and direction-of-arrival are part of the reproduced sound field while preserving the model complete formulation that coherently combines frequency and spatial responses. Modifications to the standard 2.5D WFS operators are proposed for extended primary sources, affecting the reference line definition and compensating for out-of-plane elementary primary sources. Reported simulations and experiments of reproductions of two physically-accurate vibroacoustic models of thin plates show that the proposed method allows for an effective reproduction in the horizontal plane: Spatial and frequency domains features are recreated. Application of the method to the sound rendering of a virtual transmission loss measurement setup shows the potential of the method for use in virtual acoustical prototyping for jury testing.

  6. Broadband Transmission Loss Using the Overlap of Resonances in 3D Sonic Crystals

    Directory of Open Access Journals (Sweden)

    Alexandre Lardeau

    2016-05-01

    Full Text Available The acoustic properties of a three-dimensional sonic crystal made of square-rod rigid scatterers incorporating a periodic arrangement of quarter wavelength resonators are theoretically and experimentally reported in this work. The periodicity of the system produces Bragg band gaps that can be tuned in frequency by modifying the orientation of the square-rod scatterers with respect to the incident wave. In addition, the quarter wavelength resonators introduce resonant band gaps that can be tuned by coupling the neighbor resonators. Bragg and resonant band gaps can overlap allowing the wave propagation control inside the periodic resonant medium. In particular, we show theoretically and experimentally that this system can produce a broad frequency band gap exceeding two and a half octaves (from 590 Hz to 3220 Hz with transmission lower than 3%. Finite element methods were used to calculate the dispersion relation of the locally resonant system. The visco-thermal losses were accounted for in the quarter wavelength resonators to simulate the wave propagation in the semi-infinite structures and to compare the numerical results with the experiments performed in an echo-free chamber. The simulations and the experimental results are in good agreement. This work motivates interesting applications of this system as acoustic audible filters.

  7. Influence of the airflow speed along transmission lines on the DC corona discharge loss, using finite element approach

    Energy Technology Data Exchange (ETDEWEB)

    Shemshadi, A.; Akbari, A. [Electric Department, K. N. Toosi University of Technology, Tehran (Iran, Islamic Republic of); Niayesh, K. [Electric Engineering Department, Tehran University, Tehran (Iran, Islamic Republic of)

    2012-07-15

    Corona discharge is of great interest from the physical point of view and due to its numerous practical applications in industry and especially one of the most important sources of loss in the high voltage transmission lines. This paper provides guidelines for the amount of electric loss caused by corona phenomenon occurred around a DC high voltage wire placed between two flat plates and influence of wind speed rate on the amount of corona loss using COMSOL Multiphysics. So electric potential distribution patterns and charge density diffusion around the wire are studied in this article.

  8. The Dehydration of Water Worlds via Atmospheric Losses

    Energy Technology Data Exchange (ETDEWEB)

    Dong, Chuanfei; Bhattacharjee, Amitava [Department of Astrophysical Sciences, Princeton University, Princeton, NJ 08544 (United States); Huang, Zhenguang; Tóth, Gábor; Gombosi, Tamas [Center for Space Environment Modeling, University of Michigan, Ann Arbor, MI 48109 (United States); Lingam, Manasvi, E-mail: dcfy@princeton.edu [Harvard-Smithsonian Center for Astrophysics, Cambridge, MA 02138 (United States)

    2017-09-20

    We present a three-species multi-fluid magnetohydrodynamic model (H{sup +}, H{sub 2}O{sup +}, and e {sup −}), endowed with the requisite atmospheric chemistry, that is capable of accurately quantifying the magnitude of water ion losses from exoplanets. We apply this model to a water world with Earth-like parameters orbiting a Sun-like star for three cases: (i) current normal solar wind conditions, (ii) ancient normal solar wind conditions, and (iii) one extreme “Carrington-type” space weather event. We demonstrate that the ion escape rate for (ii), with a value of 6.0 × 10{sup 26} s{sup −1}, is about an order of magnitude higher than the corresponding value of 6.7 × 10{sup 25} s{sup −1} for (i). Studies of ion losses induced by space weather events, where the ion escape rates can reach ∼10{sup 28} s{sup −1}, are crucial for understanding how an active, early solar-type star (e.g., with frequent coronal mass ejections) could have accelerated the depletion of the exoplanet’s atmosphere. We briefly explore the ramifications arising from the loss of water ions, especially for planets orbiting M-dwarfs where such effects are likely to be significant.

  9. The Dehydration of Water Worlds via Atmospheric Losses

    International Nuclear Information System (INIS)

    Dong, Chuanfei; Bhattacharjee, Amitava; Huang, Zhenguang; Tóth, Gábor; Gombosi, Tamas; Lingam, Manasvi

    2017-01-01

    We present a three-species multi-fluid magnetohydrodynamic model (H"+, H_2O"+, and e "−), endowed with the requisite atmospheric chemistry, that is capable of accurately quantifying the magnitude of water ion losses from exoplanets. We apply this model to a water world with Earth-like parameters orbiting a Sun-like star for three cases: (i) current normal solar wind conditions, (ii) ancient normal solar wind conditions, and (iii) one extreme “Carrington-type” space weather event. We demonstrate that the ion escape rate for (ii), with a value of 6.0 × 10"2"6 s"−"1, is about an order of magnitude higher than the corresponding value of 6.7 × 10"2"5 s"−"1 for (i). Studies of ion losses induced by space weather events, where the ion escape rates can reach ∼10"2"8 s"−"1, are crucial for understanding how an active, early solar-type star (e.g., with frequent coronal mass ejections) could have accelerated the depletion of the exoplanet’s atmosphere. We briefly explore the ramifications arising from the loss of water ions, especially for planets orbiting M-dwarfs where such effects are likely to be significant.

  10. Evaluation of the apparent losses caused by water meter under-registration in intermittent water supply.

    Science.gov (United States)

    Criminisi, A; Fontanazza, C M; Freni, G; Loggia, G La

    2009-01-01

    Apparent losses are usually caused by water theft, billing errors, or revenue meter under-registration. While the first two causes are directly related to water utility management and may be reduced by improving company procedures, water meter inaccuracies are considered to be the most significant and hardest to quantify. Water meter errors are amplified in networks subjected to water scarcity, where users adopt private storage tanks to cope with the intermittent water supply. The aim of this paper is to analyse the role of two variables influencing the apparent losses: water meter age and the private storage tank effect on meter performance. The study was carried out in Palermo (Italy). The impact of water meter ageing was evaluated in laboratory by testing 180 revenue meters, ranging from 0 to 45 years in age. The effects of the private water tanks were determined via field monitoring of real users and a mathematical model. This study demonstrates that the impact on apparent losses from the meter starting flow rapidly increases with meter age. Private water tanks, usually fed by a float valve, overstate meter under-registration, producing additional apparent losses between 15% and 40% for the users analysed in this study.

  11. Electron energy loss spectroscopy microanalysis and imaging in the transmission electron microscope: example of biological applications

    International Nuclear Information System (INIS)

    Diociaiuti, Marco

    2005-01-01

    This paper reports original results obtained in our laboratory over the past few years in the application of both electron energy loss spectroscopy (EELS) and electron spectroscopy imaging (ESI) to biological samples, performed in two transmission electron microscopes (TEM) equipped with high-resolution electron filters and spectrometers: a Gatan model 607 single magnetic sector double focusing EEL serial spectrometer attached to a Philips 430 TEM and a Zeiss EM902 Energy Filtering TEM. The primary interest was on the possibility offered by the combined application of these spectroscopic techniques with those offered by the TEM. In particular, the electron beam focusing available in a TEM allowed us to perform EELS and ESI on very small sample volumes, where high-resolution imaging and electron diffraction techniques can provide important structural information. I show that ESI was able to improve TEM performance, due to the reduced chromatic aberration and the possibility of avoiding the sample staining procedure. Finally, the analysis of the oscillating extended energy loss fine structure (EXELFS) beyond the ionization edges characterizing the EELS spectra allowed me, in a manner very similar to the extended X-ray absorption fine structure (EXAFS) analysis of the X-ray absorption spectra, to obtain short-range structural information for such light elements of biological interest as O or Fe. The Philips EM430 (250-300 keV) TEM was used to perform EELS microanalysis on Ca, P, O, Fe, Al and Si. The assessment of the detection limits of this method was obtained working with well-characterized samples containing Ca and P, and mimicking the actual cellular matrix. I applied EELS microanalysis to Ca detection in bone tissue during the mineralization process and to P detection in the cellular membrane of erythrocytes treated with an anti-tumoral drug, demonstrating that the cellular membrane is a drug target. I applied EELS microanalysis and selected area electron

  12. The measurement of the transmission loss of single leaf walls and panels by an impulse method

    Science.gov (United States)

    Balilah, Y. A.; Gibbs, B. M.

    1988-06-01

    The standard methods of measurement and rating of sound insulation of panels and walls are generally time-consuming and require expensive and often bulky equipment. In addition, the methods establish only that there has been failure to comply with insulation requirements without indicating the mode of failure. An impulse technique is proposed for the measurement of walls and partitions in situ. The method requires the digital capture of a short duration signal generated by a loudspeaker, and the isolation of the direct component from other reflected and scattered components by time-of-flight methods and windowing. The signal, when transferred from the time to frequency domain by means of fast Fourier transforms, can yield the sound insulation of a partition expressed as a transfer function. Experimental problems in the use of this technique, including those resulting from sphericity of the incident wave front and concentric bending excitation of the partition, are identified and methods proposed for their elimination. Most of the results presented are of single leaf panels subjected to sound at normal incidence, although some measurements were undertaken at oblique incidence. The range of surface densities considered was 7-500 kg/m 2, the highest value corresponding to a brick and plaster wall of thickness 285 mm. Measurement is compared with theoretical prediction, at one-third octave intervals in a frequency range of 100-5000 Hz, or as a continuous function of frequency with a typical resolution of 12·5 Hz. The dynamic range of the measurement equipment sets an upper limit to the measurable transmission loss. For the equipment eventually employed this was represented by a random incidence value of 50 dB.

  13. Virtual scarce water embodied in inter-provincial electricity transmission in China

    International Nuclear Information System (INIS)

    Zhang, Chao; Zhong, Lijin; Liang, Sai; Sanders, Kelly T.; Wang, Jiao; Xu, Ming

    2017-01-01

    Highlights: • Virtual water in inter-provincial electricity transmission in China is calculated. • A Water Stress Index is used to reflect relative scarcity of water consumption. • West Inner Mongolia is the largest exporter of scarce water. • Hebei, Beijing and Shandong are the three largest receivers of scarce water. - Abstract: Intra-national electricity transmission drives virtual water transfer from electricity production regions to electricity consumption regions. In China, the water-intensive thermoelectric power industry is expanding quickly in many water-scarce energy production hubs in northern and northwestern provinces. This study constructed a node-flow model of inter-provincial electricity transmission to investigate the virtual water and scarcity-adjusted virtual water (or virtual scarce water) embodied in the electricity transmission network. It is revealed that total inter-provincial virtual water transfer embodied in electricity transmission was 623 million m"3 in 2011, equivalent to 12.7% of the national total thermoelectric water consumption. The top three largest single virtual water flows are West Inner Mongolia-to-Beijing (44 million m"3), East Inner Mongolia-to-Liaoning (39 million m"3), and Guizhou-to-Guangdong (37 million m"3). If the actual volumes of consumptive water use are translated into scarcity-adjusted water consumption based on Water Stress Index, West Inner Mongolia (81 million m"3), Shanxi (63 million m"3) and Ningxia (30 million m"3) become the top three exporters of virtual scarce water. Many ongoing long-distance electricity transmission projects in China will enlarge the scale of scarce water outflows from northwestern regions and potentially increase their water stress.

  14. An Optimal Domestic Electric Vehicle Charging Strategy for Reducing Network Transmission Loss While Taking Seasonal Factors into Consideration

    Directory of Open Access Journals (Sweden)

    Yuancheng Zhao

    2018-01-01

    Full Text Available With the rapid growth of domestic electric vehicle charging loads, the peak-valley gap and power fluctuation rate of power systems increase sharply, which can lead to the increase of network losses and energy efficiency reduction. This paper tries to regulate network loads and reduce power system transmission loss by optimizing domestic electric vehicle charging loads. In this paper, a domestic electric vehicle charging loads model is first developed by analyzing the key factors that can affect users’ charging behavior. Subsequently, the Monte Carlo method is proposed to simulate the power consumption of a cluster of domestic electric vehicles. After that, an optimal electric vehicle charging strategy based on the 0-1 integer programming is presented to regulate network daily loads. Finally, by taking the IEEE33 distributed power system as an example, this paper tries to verify the efficacy of the proposed optimal charging strategy and the necessity for considering seasonal factors when scheduling electric vehicle charging loads. Simulation results show that the proposed 0-1 integer programming method does have good performance in reducing the network peak-valley gap, voltage fluctuation rate, and transmission loss. Moreover, it has some potential to further reduce power system transmission loss when seasonal factors are considered.

  15. Evaluation of the water equivalence of solid phantoms using gamma ray transmission measurements

    International Nuclear Information System (INIS)

    Hill, R.F.; Brown, S.; Baldock, C.

    2008-01-01

    Gamma ray transmission measurements have been used to evaluate the water equivalence of solid phantoms. Technetium-99m was used in narrow beam geometry and the transmission of photons measured, using a gamma camera, through varying thickness of the solid phantom material and water. Measured transmission values were compared with Monte Carlo calculated transmission data using the EGSnrc Monte Carlo code to score fluence in a geometry similar to that of the measurements. The results indicate that the RMI457 Solid Water, CMNC Plastic Water and PTW RW3 solid phantoms had similar transmission values as compared to water to within ±1.5%. However, Perspex had a greater deviation in the transmission values up to ±4%. The agreement between the measured and EGSnrc calculated transmission values agreed to within ±1% over the range of phantom thickness studied. The linear attenuation coefficients at the gamma ray energy of 140.5 keV were determined from the measured and EGSnrc calculated transmission data and compared with predicted values derived from data provided by the National Institute of Standards and Technology (NIST) using the XCOM program. The coefficients derived from the measured data were up to 6% lower than those predicted by the XCOM program, while the coefficients determined from the Monte Carlo calculations were between measured and XCOM values. The results indicate that a similar process can be followed to determine the water equivalency of other solid phantoms and at other photon energies

  16. How Does Silicon Mediate Plant Water Uptake and Loss Under Water Deficiency?

    Directory of Open Access Journals (Sweden)

    Daoqian Chen

    2018-03-01

    Full Text Available In plants, water deficiency can result from a deficit of water from the soil, an obstacle to the uptake of water or the excess water loss; in these cases, the similar consequence is the limitation of plant growth and crop yield. Silicon (Si has been widely reported to alleviate the plant water status and water balance under variant stress conditions in both monocot and dicot plants, especially under drought and salt stresses. However, the underlying mechanism is unclear. In addition to the regulation of leaf transpiration, recently, Si application was found to be involved in the adjustment of root hydraulic conductance by up-regulating aquaporin gene expression and concentrating K in the xylem sap. Therefore, this review discusses the potential effects of Si on both leaf transpiration and root water absorption, especially focusing on how Si modulates the root hydraulic conductance. A growing number of studies support the conclusion that Si application improves plant water status by increasing root water uptake, rather than by decreasing their water loss under conditions of water deficiency. The enhancement of plant water uptake by Si is achievable through the activation of osmotic adjustment, improving aquaporin activity and increasing the root/shoot ratio. The underlying mechanisms of the Si on improving plant water uptake under water deficiency conditions are discussed.

  17. Loss of coolant accident at boiling water reactors

    International Nuclear Information System (INIS)

    Ramirez G, R.

    1975-01-01

    A revision is made with regard to the methods of thermohydraulic analysis which are used at present in order to determine the efficiency of the safety systems against loss of coolant at boiling water reactors. The object is to establish a program of work in the INEN so that the personnel in charge of the safety of the nuclear plants in Mexico, be able to make in a near future, independent valuations of the safety systems which mitigate the consequences of the above mentioned accident. (author)

  18. SOUND TRANSMISSION LOSS OF A DOUBLE-LEAF PARTITION WITH MICRO-PERFORATED PLATE INSERTION UNDER DIFFUSE FIELD INCIDENCE

    Directory of Open Access Journals (Sweden)

    A. Putra

    2013-06-01

    Full Text Available In noise control applications, a double-leaf partition has been applied widely as a lightweight structure for noise insulation, such as in car doors, train bodies, and aircraft fuselages. Unfortunately, the insulation performance deteriorates significantly at mass-air-mass resonance due to coupling between the panels and the air in the gap. This paper investigates the effect of a micro-perforated panel (MPP, inserted in the conventional double-panel partition, on sound transmission loss at troublesome resonant frequencies. It is found that the transmission loss improves at this resonance if the MPP is located at a distance of less than half that of the air gap. A mathematical model is derived for the diffuse field incidence of acoustic loading.

  19. The use of acoustically tuned resonators to improve the sound transmission loss of double-panel partitions

    Science.gov (United States)

    Mason, J. M.; Fahy, F. J.

    1988-07-01

    Double-leaf partitions are often utilized in situations requiring low weight structures with high transmission loss, an example of current interest being the fuselage walls of propeller-driven aircraft. In this case, acoustic excitation is periodic and, if one of the frequencies of excitation lies in the region of the fundamental mass-air-mass frequency of the partition, insulation performance is considerably less than desired. The potential effectiveness of tuned Helmholtz resonators connected to the partition cavity is investigated as a method of improving transmission loss. This is demonstrated by a simple theoretical model and then experimentally verified. Results show that substantial improvements may be obtained at and around the mass-air-mass frequency for a total resonator volume 15 percent of the cavity volume.

  20. Normal Incidence of Sound Transmission Loss of a Double-Leaf Partition Inserted with a Microperforated Panel

    OpenAIRE

    Putra, A.; Ismail, A. Y.; Ramlan, R.; Ayob, Md. R.; Py, M. S.

    2013-01-01

    A double-leaf partition in engineering structures has been widely applied for its advantages, that is, in terms of its mechanical strength as well as its lightweight property. In noise control, the double-leaf also serves as an effective noise barrier. Unfortunately at low frequency, the sound transmission loss reduces significantly due to the coupling between the panels and the air between them. This paper studies the effect of a microperforated panel (MPP) inserted inside a double-leaf part...

  1. Weight loss and survival of Biomphalaria Glabrata deprived of water

    Directory of Open Access Journals (Sweden)

    Marc Vianey-Liaud

    1986-06-01

    Full Text Available Immature and mature Biomphalaria glabrata are kept out of water at relative humidities varying from 0 to 100%. When snails are submitted to a saturated atmosphere, they show a slow weight loss and survival may be long. If relative humidity (RH decreases, weight loss becomes important and survival is short. A reduced RH (0 to 65% produces similar effects. During desiccation, fasting has no noticeable effect; survival depends essentially on weight loss.Biomphalaria glabrata maduros ou imaturos são mantidos fora da água, variando a umidade de 0 a 100%. Quando caramujos são submetidos a uma atmosfera saturada, sofrem uma lenta perda de peso e a sobrevivência pode ser longa. Se a umidade relativa decresce, a perda de peso será importante e a sobrevida será abreviada. Uma umidade relativa de 0 a 65% pode produzir efeitos similares. Durante a dessecação, a privação de alimento não tem efeito notável, a sobrevivência dependendo essencialmente da perda de peso.

  2. Relative specificities of water and ammonia losses from backbone fragments in collision-activated dissociation

    DEFF Research Database (Denmark)

    Savitski, Mikhail M; Kjeldsen, Frank; Nielsen, Michael L

    2007-01-01

    isotope of the water loss and the monoisotope of the ammonia loss to be distinguished. Contrary to a popular belief, water losses from y' ions are not specific enough to rely upon for detecting the presence of amino acids with oxygen in the side chains. At the same time, ammonia loss from b ions...

  3. Domestic water buffaloes: Access to surface water, disease prevalence and associated economic losses.

    Science.gov (United States)

    Elahi, Ehsan; Abid, Muhammad; Zhang, Huiming; Cui, Weijun; Ul Hasson, Shabeh

    2018-06-01

    Given the shortage and non-availability of freshwater in Pakistan, wastewater is being used for bathing water buffaloes; however, this has a negative impact on animal welfare. Although there is a vast literature on indirect linkages between wastewater and animal productivity, studies focusing on the direct impacts of water buffaloes bathing in wastewater on animal productivity and economic losses are rare. Therefore, using 360 domestic water buffalo farms, this study examines the expenditure and production losses associated with bathing (in wastewater and freshwater) and non-bathing water buffaloes by employing partial budgeting and resource adjustment component techniques. Furthermore, it investigates the prevalence of animal diseases and associated economic effects using correlation analysis and propensity score matching techniques, respectively. The findings reveal that compared to their counterparts (freshwater bathing and non-bathing water buffaloes), buffaloes bathing in wastewater are at increased risk of clinical mastitis, foot and mouth disease (FMD) and tick infestation. Moreover, the use of wastewater for bathing buffaloes also leads to higher economic and production losses by affecting milk productivity, causing premature culling, and reducing slaughter value. The findings of the double-log model show that economic losses are higher if buffaloes bathe in wastewater within 30 min after milking, as there are more chances that those buffaloes would be exposed to bacterial penetration in the teat ducts, which may result in intramammary infection. According to the propensity score matching method, the higher economic damages per month are associated with buffaloes bathing in wastewater and freshwater, 155 and 110 USD per farm, respectively. The study findings reference the need for policies to restrict wastewater access by water buffaloes, and a regular check of and access to cool clean water wallows for bathing during hot summer days, to reduce excess

  4. Alternating current loss calculation in a high-TC superconducting transmission cable considering the magnetic field distribution

    International Nuclear Information System (INIS)

    Noji, H; Haji, K; Hamada, T

    2003-01-01

    We have calculated the alternating current (ac) losses of a 114 MVA high-T C superconducting (HTS) transmission cable using an electric-circuit (EC) model. The HTS cable is fabricated by Tokyo Electric Power Company and Sumitomo Electric Industries, Ltd. The EC model is comprised of a resistive part and an inductive part. The resistive part is obtained by the approximated Norris equation for a HTS tape. The Norris equation indicates hysteresis losses due to self-fields. The inductive part has two components, i.e. inductances related to axial fields and those related to circumferential fields. The layer currents and applied fields of each layer were calculated by the EC model. By using both values, the ac losses of the one-phase HTS cable were obtained by calculation considering the self-field, the axial field and the circumferential field of the HTS tape. The measured ac loss transporting 1 kA rms is 0.7 W m -1 ph -1 , which is equal to the calculation. The distribution of each layer loss resembles in shape the distribution of the circumferential field in each layer, which indicates that the circumferential fields strongly influence the ac losses of the HTS cable

  5. Evaporative water loss, relative water economy and evaporative partitioning of a heterothermic marsupial, the monito del monte (Dromiciops gliroides).

    Science.gov (United States)

    Withers, Philip C; Cooper, Christine E; Nespolo, Roberto F

    2012-08-15

    We examine here evaporative water loss, economy and partitioning at ambient temperatures from 14 to 33°C for the monito del monte (Dromiciops gliroides), a microbiotheriid marsupial found only in temperate rainforests of Chile. The monito's standard evaporative water loss (2.58 mg g(-1) h(-1) at 30°C) was typical for a marsupial of its body mass and phylogenetic position. Evaporative water loss was independent of air temperature below thermoneutrality, but enhanced evaporative water loss and hyperthermia were the primary thermal responses above the thermoneutral zone. Non-invasive partitioning of total evaporative water loss indicated that respiratory loss accounted for 59-77% of the total, with no change in respiratory loss with ambient temperature, but a small change in cutaneous loss below thermoneutrality and an increase in cutaneous loss in and above thermoneutrality. Relative water economy (metabolic water production/evaporative water loss) increased at low ambient temperatures, with a point of relative water economy of 15.4°C. Thermolability had little effect on relative water economy, but conferred substantial energy savings at low ambient temperatures. Torpor reduced total evaporative water loss to as little as 21% of normothermic values, but relative water economy during torpor was poor even at low ambient temperatures because of the relatively greater reduction in metabolic water production than in evaporative water loss. The poor water economy of the monito during torpor suggests that negative water balance may explain why hibernators periodically arouse to normothermia, to obtain water by drinking or via an improved water economy.

  6. Real-time dynamic hydraulic model for potable water loss reduction

    CSIR Research Space (South Africa)

    Abu-Mahfouz, Adnan M

    2016-08-01

    Full Text Available South Africa is a water scarce country with limited water resources and steadily growing water demand. Unacceptably high water losses and non-revenue water threaten our water resource security as well as the financial viability of municipal water...

  7. The 2014 water release into the arid Colorado River delta and associated water losses by evaporation

    Energy Technology Data Exchange (ETDEWEB)

    Daesslé, L.W., E-mail: walter@uabc.edu.mx [Instituto de Investigaciones Oceanológicas, Universidad Autónoma de Baja California, CarreteraTranspeninsular Tijuana-Ensenada No. 3917, Fraccionamiento Playitas, CP 22860 Ensenada, Baja California (Mexico); Friedrich-Alexander University of Erlangen-Nuremberg (FAU), Department of Geography and Geosciences, GeoZentrum Nordbayern, Schlossgarten 5, 91054 Erlangen (Germany); Geldern, R. van [Friedrich-Alexander University of Erlangen-Nuremberg (FAU), Department of Geography and Geosciences, GeoZentrum Nordbayern, Schlossgarten 5, 91054 Erlangen (Germany); Orozco-Durán, A. [Instituto de Investigaciones Oceanológicas, Universidad Autónoma de Baja California, CarreteraTranspeninsular Tijuana-Ensenada No. 3917, Fraccionamiento Playitas, CP 22860 Ensenada, Baja California (Mexico); Barth, J.A.C. [Friedrich-Alexander University of Erlangen-Nuremberg (FAU), Department of Geography and Geosciences, GeoZentrum Nordbayern, Schlossgarten 5, 91054 Erlangen (Germany)

    2016-01-15

    For the first time in history, water was intentionally released for environmental purposes into the final, otherwise dry, 160-km stretch of the Colorado River basin, south of the Mexican border. Between March and May 2014 three pulses of water with a total volume of 132 × 10{sup 6} m{sup 3} were released to assess the restoration potential of endemic flora along its course and to reach its estuary. The latter had not received a sustained input of fresh water and nutrients from its main fluvial source for over 50 years because of numerous upstream dam constructions. During this pulse flow large amounts of water were lost and negligible amounts reached the ocean. While some of these water losses can be attributed to plant uptake and infiltration, we were able to quantify evaporation losses between 16.1 to 17.3% of the original water mass % within the first 80 km after the Morels Dam with water stable isotope data. Our results showed no evidence for freshwater reaching the upper Colorado River estuary and it is assumed that the pulse flow had only negligible influences on the coastal ecosystem. Future water releases that aim on ecological restoration need to become more frequent and should have larger volumes if more significant effects are to be established on the area. - Highlights: • Isotope ratios of oxygen and hydrogen quantify water lost through evaporation. • Evaporation losses between 16.1 and 17.3% during the 2014 Colorado River • Larger water volumes are required to influence the estuary ecosystem.

  8. The 2014 water release into the arid Colorado River delta and associated water losses by evaporation

    International Nuclear Information System (INIS)

    Daesslé, L.W.; Geldern, R. van; Orozco-Durán, A.; Barth, J.A.C.

    2016-01-01

    For the first time in history, water was intentionally released for environmental purposes into the final, otherwise dry, 160-km stretch of the Colorado River basin, south of the Mexican border. Between March and May 2014 three pulses of water with a total volume of 132 × 10"6 m"3 were released to assess the restoration potential of endemic flora along its course and to reach its estuary. The latter had not received a sustained input of fresh water and nutrients from its main fluvial source for over 50 years because of numerous upstream dam constructions. During this pulse flow large amounts of water were lost and negligible amounts reached the ocean. While some of these water losses can be attributed to plant uptake and infiltration, we were able to quantify evaporation losses between 16.1 to 17.3% of the original water mass % within the first 80 km after the Morels Dam with water stable isotope data. Our results showed no evidence for freshwater reaching the upper Colorado River estuary and it is assumed that the pulse flow had only negligible influences on the coastal ecosystem. Future water releases that aim on ecological restoration need to become more frequent and should have larger volumes if more significant effects are to be established on the area. - Highlights: • Isotope ratios of oxygen and hydrogen quantify water lost through evaporation. • Evaporation losses between 16.1 and 17.3% during the 2014 Colorado River • Larger water volumes are required to influence the estuary ecosystem.

  9. Expanded prediction equations of human sweat loss and water needs.

    Science.gov (United States)

    Gonzalez, R R; Cheuvront, S N; Montain, S J; Goodman, D A; Blanchard, L A; Berglund, L G; Sawka, M N

    2009-08-01

    The Institute of Medicine expressed a need for improved sweating rate (msw) prediction models that calculate hourly and daily water needs based on metabolic rate, clothing, and environment. More than 25 years ago, the original Shapiro prediction equation (OSE) was formulated as msw (g.m(-2).h(-1))=27.9.Ereq.(Emax)(-0.455), where Ereq is required evaporative heat loss and Emax is maximum evaporative power of the environment; OSE was developed for a limited set of environments, exposures times, and clothing systems. Recent evidence shows that OSE often overpredicts fluid needs. Our study developed a corrected OSE and a new msw prediction equation by using independent data sets from a wide range of environmental conditions, metabolic rates (rest to losses were carefully measured in 101 volunteers (80 males and 21 females; >500 observations) by using a variety of metabolic rates over a range of environmental conditions (ambient temperature, 15-46 degrees C; water vapor pressure, 0.27-4.45 kPa; wind speed, 0.4-2.5 m/s), clothing, and equipment combinations and durations (2-8 h). Data are expressed as grams per square meter per hour and were analyzed using fuzzy piecewise regression. OSE overpredicted sweating rates (Pdata (21 males and 9 females; >200 observations). OSEC and PW were more accurate predictors of sweating rate (58 and 65% more accurate, Perror (standard error estimate<100 g.m(-2).h(-1)) for conditions both within and outside the original OSE domain of validity. The new equations provide for more accurate sweat predictions over a broader range of conditions with applications to public health, military, occupational, and sports medicine settings.

  10. Transmission electron microscopy characterization of photocatalysts for water splitting

    DEFF Research Database (Denmark)

    Cavalca, Filippo; Laursen, Anders Bo; Dahl, Søren

    , it is necessary to understand the fundamentals of their reaction mechanisms, chemical behavior, structure and morphology before, during and after reaction using in situ investigations. Here, we focus on the in situ characterization of photocatalysts [1] in an environmental transmission electron microscope (ETEM......) [2]. Such fundamental insight can be used for further material optimization with respect to performance and stability [3]. In this work, we combine conventional TEM analysis of photocatalysts with environmental TEM (ETEM) and photoactivation using light. A novel type of TEM specimen holder...... that enables in situ illumination is developed to study light-induced phenomena in photoactive materials at the nanoscale under working conditions. Our experiments are aimed at exposing a specimen to light and detecting resulting microstructural and chemical changes using in situ TEM techniques...

  11. Structural defects in multiferroic BiMnO3 studied by transmission electron microscopy and electron energy-loss spectroscopy

    International Nuclear Information System (INIS)

    Yang, H.; Chi, Z. H.; Yao, L. D.; Zhang, W.; Li, F. Y.; Jin, C. Q.; Yu, R. C.

    2006-01-01

    The multiferroic material BiMnO 3 synthesized under high pressure has been systematically studied by transmission electron microscopy and electron energy-loss spectroscopy, and some important structural defects are revealed in this multiferroic material. The frequently observed defects are characterized to be Σ3(111) twin boundaries, Ruddlesden-Popper [Acta Crystallogr. 11, 54 (1958)] antiphase boundaries, and a p p superdislocations connected with a small segment of Ruddlesden-Popper defect. These defects are present initially in the as-synthesized sample. In addition, we find that ordered voids (oxygen vacancies) are easily introduced into the multiferroic BiMnO 3 by electron-beam irradiation

  12. The development of a subsea power transmission system for deep water boosting applications

    Energy Technology Data Exchange (ETDEWEB)

    Godinho, C.A.F. [Pirelli Cabos S.A. (Brazil); Campagnac, L.A. [Siemens S.A. (Brazil); Nicholson, A. [Tronic Electronics Services Ltd. (WEC); Magalhaes, W.M. de [PETROBRAS, Rio de Janeiro, RJ (Brazil)

    1996-12-31

    This paper presents the development of a sub sea power transmission in medium voltage and variable frequency, as a key system for application of Boosting technology and for electrical submersible Pumping in deep water wells. This work focuses on the design and manufacture of sub sea power cables and transformers for 1,000 m water depth. 8 refs., 6 figs.

  13. Reducing nitrate loss in tile drainage water with cover crops and water-table management systems.

    Science.gov (United States)

    Drury, C F; Tan, C S; Welacky, T W; Reynolds, W D; Zhang, T Q; Oloya, T O; McLaughlin, N B; Gaynor, J D

    2014-03-01

    Nitrate lost from agricultural soils is an economic cost to producers, an environmental concern when it enters rivers and lakes, and a health risk when it enters wells and aquifers used for drinking water. Planting a winter wheat cover crop (CC) and/or use of controlled tile drainage-subirrigation (CDS) may reduce losses of nitrate (NO) relative to no cover crop (NCC) and/or traditional unrestricted tile drainage (UTD). A 6-yr (1999-2005) corn-soybean study was conducted to determine the effectiveness of CC+CDS, CC+UTD, NCC+CDS, and NCC+UTD treatments for reducing NO loss. Flow volume and NO concentration in surface runoff and tile drainage were measured continuously, and CC reduced the 5-yr flow-weighted mean (FWM) NO concentration in tile drainage water by 21 to 38% and cumulative NO loss by 14 to 16% relative to NCC. Controlled tile drainage-subirrigation reduced FWM NO concentration by 15 to 33% and cumulative NO loss by 38 to 39% relative to UTD. When CC and CDS were combined, 5-yr cumulative FWM NO concentrations and loss in tile drainage were decreased by 47% (from 9.45 to 4.99 mg N L and from 102 to 53.6 kg N ha) relative to NCC+UTD. The reductions in runoff and concomitant increases in tile drainage under CC occurred primarily because of increases in near-surface soil hydraulic conductivity. Cover crops increased corn grain yields by 4 to 7% in 2004 increased 3-yr average soybean yields by 8 to 15%, whereas CDS did not affect corn or soybean yields over the 6 yr. The combined use of a cover crop and water-table management system was highly effective for reducing NO loss from cool, humid agricultural soils. Copyright © by the American Society of Agronomy, Crop Science Society of America, and Soil Science Society of America, Inc.

  14. Measurement of transepidermal water loss in localized scleroderma.

    Science.gov (United States)

    Ďurčanská, Veronika; Jedličková, Hana; Vašků, Vladimír

    2016-05-01

    Localized scleroderma (LS) is a disease characterized by fibrotic changes in the dermis. Connective tissue growth factor and transforming growth factor β2 are the main mediators of fibrogenesis; this, along with excessive connective tissue production, affects epidermal keratinocytes, and thereby contributes to the changed quality of skin barrier. The objective of this article was to study the objective measurement of the skin barrier quality in LS with transepidermal water loss (TEWL) meter. The measurements of TEWL were performed on LS plaques in all three stages of various body locations. Control measurements were made on the contralateral side of healthy skin. The difference between TEWL in LS area and the contralateral side of the healthy skin was evaluated. A higher average TEWL 7.86 g/m(2) /h (SD 5.29) was observed on LS plaques compared with the control measurements on healthy skin 6.39 g/m(2) /h (SD 2.77). TEWL average values decreased from the inflammatory stage, through the sclerotic and to the atrophic stage. The mean difference 1.301 g/m(2) /h (SD 5.16) was found between TEWL on LS plaques and on the contralateral healthy skin in 82 measurements, i.e., a higher TEWL was observed in LS. The difference was statistically significant with p = 0.0250. Although fibrogenesis in scleroderma is localized in dermis, the skin barrier changes can be detected. © 2016 Wiley Periodicals, Inc.

  15. Transmission and signal loss in mask designs for a dual neutron and gamma imager applied to mobile standoff detection

    International Nuclear Information System (INIS)

    Ayaz-Maierhafer, Birsen; Hayward, Jason P.; Ziock, Klaus P.; Blackston, Matthew A.; Fabris, Lorenzo

    2013-01-01

    In order to design a next-generation, dual neutron and gamma imager for mobile standoff detection which uses coded aperture imaging as its primary detection modality, the following design parameters have been investigated for gamma and neutron radiation incident upon a hybrid, coded mask: (1) transmission through mask elements for various mask materials and thicknesses; and (2) signal attenuation in the mask versus angle of incidence. Each of these parameters directly affects detection significance, as quantified by the signal-to-noise ratio. The hybrid mask consists of two or three layers: organic material for fast neutron attenuation and scattering, Cd for slow neutron absorption (if applied), and one of three of the following photon or photon and slow neutron attenuating materials—Linotype alloy, CLYC, or CZT. In the MCNP model, a line source of gamma rays (100–2500 keV), fast neutrons (1000–10,000 keV) or thermal neutrons was positioned above the hybrid mask. The radiation penetrating the mask was simply tallied at the surface of an ideal detector, which was located below the surface of the last mask layer. The transmission was calculated as the ratio of the particles transmitted through the fixed aperture to the particles passing through the closed mask. In order to determine the performance of the mask considering relative motion between the source and detector, simulations were used to calculate the signal attenuation for incident radiation angles of 0–50°. The results showed that a hybrid mask can be designed to sufficiently reduce both transmission through the mask and signal loss at large angles of incidence, considering both gamma ray and fast neutron radiations. With properly selected material thicknesses, the signal loss of a hybrid mask, which is necessarily thicker than the mask required for either single mode imaging, is not a setback to the system's detection significance

  16. Reduction of eddy current losses in inductive transmission systems with ferrite sheets.

    Science.gov (United States)

    Maaß, Matthias; Griessner, Andreas; Steixner, Viktor; Zierhofer, Clemens

    2017-01-05

    Improvements in eddy current suppression are necessary to meet the demand for increasing miniaturization of inductively driven transmission systems in industrial and biomedical applications. The high magnetic permeability and the simultaneously low electrical conductivity of ferrite materials make them ideal candidates for shielding metallic surfaces. For systems like cochlear implants the transmission of data as well as energy over an inductive link is conducted within a well-defined parameter set. For these systems, the shielding can be of particular importance if the properties of the link can be preserved. In this work, we investigate the effect of single and double-layered substrates consisting of ferrite and/or copper on the inductance and coupling of planar spiral coils. The examined link systems represent realistic configurations for active implantable systems such as cochlear implants. Experimental measurements are complemented with analytical calculations and finite element simulations, which are in good agreement for all measured parameters. The results are then used to study the transfer efficiency of an inductive link in a series-parallel resonant topology as a function of substrate size, the number of coil turns and coil separation. We find that ferrite sheets can be used to shield the system from unwanted metallic surfaces and to retain the inductive link parameters of the unperturbed system, particularly its transfer efficiency. The required size of the ferrite plates is comparable to the size of the coils, which makes the setup suitable for practical implementations. Since the sizes and geometries chosen for the studied inductive links are comparable to those of cochlear implants, our conclusions apply in particular to these systems.

  17. Partitioning of transpiratory water loss of the desert scorpion, Hadrurus arizonensis (Iuridae).

    Science.gov (United States)

    Gefen, Eran; Ung, Cuong; Gibbs, Allen G

    2009-06-01

    Terrestrial arthropods lose body water to the environment mainly through transpiration. The aim of this study was to determine the fraction of respiratory losses from total transpiratory water loss in scorpions, as relatively high respiratory losses would indicate a fitness benefit from regulation of gas-exchange rate under stressful desiccating conditions. We measured metabolic rates and water-loss rates of Hadrurus arizonensis (Iuridae) at a range of ecologically-relevant temperatures. Calculation of respiratory water losses was based on increased metabolic and water-loss rates during nocturnal activity (assuming no change in cuticular resistance at a given constant experimental temperature). Respiratory losses accounted for 9.0+/-1.7% of total transpiratory losses at 25 degrees C, doubled to 17.9+/-1.8% at 30 degrees C and increased to 31.0+/-2.0% at 35 degrees C (n=5, 15 and 15, respectively). Furthermore, the relative importance of respiratory transpiration is likely to be higher at temperatures above 35 degrees C, which have been recorded even within the burrows of H. arizonensis. Measurements of cuticular lipid melting points do not provide evidence for increased cuticular resistance to water loss at higher temperatures. However, the relatively high fraction of respiratory water losses reported here for H. arizonensis supports the notion of respiratory regulation as an evolved mechanism for conserving scorpion body water stores under stressful conditions.

  18. Reduction of water losses in the water utilities and in industrial plants. Senkung der Wasserverluste in oeffentlichen Versorgungen und Industrieanlagen

    Energy Technology Data Exchange (ETDEWEB)

    Bolte, O.G.; Hammerer, M.; Heide, G.F.; Heydenreich, M.; Hoch, W.; Holtschulte, H.; Lienhard, K.; Sewerin, P.

    1987-01-01

    Although municipal and rural supply structures have little changed in principle, the reduction of water losses has become a topical subject to be coped with. The paper deals with the causes and implications of water losses, the influx analysis, water loss analysis, influx analysis in the case of large-scale water supply systems, the pressure feeding method, the detection of leaks with the help of correlation analyses, the quantitave measurement of drinking water supplies and a method serving to detect least defects. In each case reference is made to the limitations of the respective methods and processes. With 95 figs..

  19. High mean water vapour pressure promotes the transmission of bacillary dysentery.

    Directory of Open Access Journals (Sweden)

    Guo-Zheng Li

    Full Text Available Bacillary dysentery is an infectious disease caused by Shigella dysenteriae, which has a seasonal distribution. External environmental factors, including climate, play a significant role in its transmission. This paper identifies climate-related risk factors and their role in bacillary dysentery transmission. Harbin, in northeast China, with a temperate climate, and Quzhou, in southern China, with a subtropical climate, are chosen as the study locations. The least absolute shrinkage and selectionator operator is applied to select relevant climate factors involved in the transmission of bacillary dysentery. Based on the selected relevant climate factors and incidence rates, an AutoRegressive Integrated Moving Average (ARIMA model is established successfully as a time series prediction model. The numerical results demonstrate that the mean water vapour pressure over the previous month results in a high relative risk for bacillary dysentery transmission in both cities, and the ARIMA model can successfully perform such a prediction. These results provide better explanations for the relationship between climate factors and bacillary dysentery transmission than those put forth in other studies that use only correlation coefficients or fitting models. The findings in this paper demonstrate that the mean water vapour pressure over the previous month is an important predictor for the transmission of bacillary dysentery.

  20. Heat Transmission Coefficient Measurements in Buildings Utilizing a Heat Loss Measuring Device

    DEFF Research Database (Denmark)

    Sørensen, Lars Schiøtt

    2013-01-01

    Global energy efficiency can be obtained in two ordinary ways. One way is to improve the energy production and supply side, and the other way is, in general, to reduce the consumption of energy in society. This paper has focus on the latter and especially the consumption of energy for heating...... and cooling our houses. There is a huge energy-saving potential in this area for reducing both the global climate problems as well as economy challenges. Heating of buildings in Denmark accounts for approximately 40% of the entire national energy consumption. For this reason, a reduction of heat losses from...... building envelopes are of great importance in order to reach the Bologna CO2 emission reduction targets. Upgrading of the energy performance of buildings is a topic of huge global interest these years. Not only heating in the temperate and arctic regions are important, but also air conditioning...

  1. Energy-water analysis of the 10-year WECC transmission planning study cases.

    Energy Technology Data Exchange (ETDEWEB)

    Tidwell, Vincent Carroll; Passell, Howard David; Castillo, Cesar; Moreland, Barbara

    2011-11-01

    In 2011 the Department of Energy's Office of Electricity embarked on a comprehensive program to assist our Nation's three primary electric interconnections with long term transmission planning. Given the growing concern over water resources in the western U.S. the Western Electricity Coordinating Council (WECC) requested assistance with integrating water resource considerations into their broader electric transmission planning. The result is a project with three overarching objectives: (1) Develop an integrated Energy-Water Decision Support System (DSS) that will enable planners in the Western Interconnection to analyze the potential implications of water stress for transmission and resource planning. (2) Pursue the formulation and development of the Energy-Water DSS through a strongly collaborative process between the Western Electricity Coordinating Council (WECC), Western Governors Association (WGA), the Western States Water Council (WSWC) and their associated stakeholder teams. (3) Exercise the Energy-Water DSS to investigate water stress implications of the transmission planning scenarios put forward by WECC, WGA, and WSWC. The foundation for the Energy-Water DSS is Sandia National Laboratories Energy-Power-Water Simulation (EPWSim) model (Tidwell et al. 2009). The modeling framework targets the shared needs of energy and water producers, resource managers, regulators, and decision makers at the federal, state and local levels. This framework provides an interactive environment to explore trade-offs, and 'best' alternatives among a broad list of energy/water options and objectives. The decision support framework is formulated in a modular architecture, facilitating tailored analyses over different geographical regions and scales (e.g., state, county, watershed, interconnection). An interactive interface allows direct control of the model and access to real-time results displayed as charts, graphs and maps. The framework currently supports

  2. HEAT LOSS FROM HOT WATER SUPPLY LINE IN A RESIDENTIAL BUILDING

    OpenAIRE

    近藤, 修平; 鉾井, 修一

    2011-01-01

    In order to the evaluate heat loss from hot water supply lines in a residential building, hot water demand in a house in Chiba prefecture was measured and analyzed. The following results were obtained. 1. The heat loss of the hot water supply line was about 132kJ for the shower and 110kJ for the bathtub in winter. Since the temperature difference between the inlet and outlet of the hot water supply line is small, the measured heat loss from the hot water supply line sometimes becomes negative...

  3. Leakage Detection and Estimation Algorithm for Loss Reduction in Water Piping Networks

    OpenAIRE

    Kazeem B. Adedeji; Yskandar Hamam; Bolanle T. Abe; Adnan M. Abu-Mahfouz

    2017-01-01

    Water loss through leaking pipes constitutes a major challenge to the operational service of water utilities. In recent years, increasing concern about the financial loss and environmental pollution caused by leaking pipes has been driving the development of efficient algorithms for detecting leakage in water piping networks. Water distribution networks (WDNs) are disperse in nature with numerous number of nodes and branches. Consequently, identifying the segment(s) of the network and the exa...

  4. Characterisation of nano-structured titanium and aluminium nitride coatings by indentation, transmission electron microscopy and electron energy loss spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Girleanu, M., E-mail: maria.girleanu@uha.fr [Mecanique, Materiaux et Procedes de Fabrication, LPMT (EA CNRS 4365), Universite de Haute Alsace, 61 rue Albert Camus, F-68093 Mulhouse (France); Pac, M.-J.; Louis, P. [Mecanique, Materiaux et Procedes de Fabrication, LPMT (EA CNRS 4365), Universite de Haute Alsace, 61 rue Albert Camus, F-68093 Mulhouse (France); Ersen, O.; Werckmann, J. [Departement Structures et Interfaces, IPCMS (UMR CNRS 7504), Universite de Strasbourg, 23 rue du Loess, F-67087 Strasbourg (France); Rousselot, C. [Departement Micro Nano Sciences et Systemes, FEMTO-ST (UMR CNRS 6174), Universite de Franche-Comte, BP 71427, F-25211 Montbeliard (France); Tuilier, M.-H. [Mecanique, Materiaux et Procedes de Fabrication, LPMT (EA CNRS 4365), Universite de Haute Alsace, 61 rue Albert Camus, F-68093 Mulhouse (France)

    2011-07-01

    Titanium and aluminium nitride Ti{sub 1-x}Al{sub x}N films deposited by radiofrequency magnetron reactive sputtering onto steel substrate are examined by transmission electron microscopy over all the range of composition (x = 0, 0.5, 0.68, 0.86, 1). The deposition parameters are optimised in order to grow nitride films with low stress over all the composition range. Transmission electron microscopy cross-section images of Vickers indentation prints performed on that set of coatings show the evolution of their damage behaviour as increasing x Al content. Cubic Ti-rich nitrides consist of small grains clustered in rather large columns sliding along each other during indentation. Hexagonal Al-rich films grow in thinner columns which can be bent under the Vickers tip. Indentation tests carried out on TiN and AlN films are simulated using finite element modelling. Particular aspects of shear stresses and displacements in the coating/substrate are investigated. The growth mode and the nanostructure of two typical films, TiN and Ti{sub 0.14}Al{sub 0.86}N, are studied in detail by combining transmission electron microscopy cross-sections and plan views. Electron energy loss spectrum taken across Ti{sub 0.14}Al{sub 0.86}N film suggests that a part of nitrogen atoms is in cubic-like local environment though the lattice symmetry of Al-rich coatings is hexagonal. The poorly crystallised domains containing Ti and N atoms in cubic-like environment are obviously located in grain boundaries and afford protection of the coating against cracking.

  5. Characterisation of nano-structured titanium and aluminium nitride coatings by indentation, transmission electron microscopy and electron energy loss spectroscopy

    International Nuclear Information System (INIS)

    Girleanu, M.; Pac, M.-J.; Louis, P.; Ersen, O.; Werckmann, J.; Rousselot, C.; Tuilier, M.-H.

    2011-01-01

    Titanium and aluminium nitride Ti 1-x Al x N films deposited by radiofrequency magnetron reactive sputtering onto steel substrate are examined by transmission electron microscopy over all the range of composition (x = 0, 0.5, 0.68, 0.86, 1). The deposition parameters are optimised in order to grow nitride films with low stress over all the composition range. Transmission electron microscopy cross-section images of Vickers indentation prints performed on that set of coatings show the evolution of their damage behaviour as increasing x Al content. Cubic Ti-rich nitrides consist of small grains clustered in rather large columns sliding along each other during indentation. Hexagonal Al-rich films grow in thinner columns which can be bent under the Vickers tip. Indentation tests carried out on TiN and AlN films are simulated using finite element modelling. Particular aspects of shear stresses and displacements in the coating/substrate are investigated. The growth mode and the nanostructure of two typical films, TiN and Ti 0.14 Al 0.86 N, are studied in detail by combining transmission electron microscopy cross-sections and plan views. Electron energy loss spectrum taken across Ti 0.14 Al 0.86 N film suggests that a part of nitrogen atoms is in cubic-like local environment though the lattice symmetry of Al-rich coatings is hexagonal. The poorly crystallised domains containing Ti and N atoms in cubic-like environment are obviously located in grain boundaries and afford protection of the coating against cracking.

  6. A Flexible Load Control Strategy for Distribution Network to Reduce the Line Losses and to Eliminate the Transmission Congestion

    Directory of Open Access Journals (Sweden)

    Beibei Wang

    2017-01-01

    Full Text Available There are many uncertain factors in the modern distribution network, including the access of renewable energy sources and the heavy load level. The existence of these factors has brought challenges to the stability of the power distribution network, as well as increasing the risk of exceeding transmission capacity of distribution lines. The appearance of flexible load control technology provides a new idea to solve the above problems. Air conditioners (ACs account for a great proportion of all loads. In this paper, the model of dispatching AC loads in the regional power grid is constructed, and the direct load control (DLC method is adopted to reduce the load of ACs. An improved tabu search technique is proposed to solve the problem of network dispatch in distribution systems in order to reduce the resistive line losses and to eliminate the transmission congestion in lines under normal operating conditions. The optimal node solution is obtained to find the best location and reduction capacity of ACs for load control. To demonstrate the validity and effectiveness of the proposed method, a test system is studied. The numerical results are also given in this article, which reveal that the proposed method is promising.

  7. Determining Permissible Oxygen and Water Vapor Transmission Rate for Non-Retort Military Ration Packaging

    Science.gov (United States)

    2011-11-01

    OXYGEN AND WATER VAPOR TRANSMISSION RATE FOR NON- RETORT MILITARY RATION PACKAGING by Danielle Froio Alan Wright Nicole Favreau and Sarah...ANSI Std. Z39.18 RETORT STORAGE SHELF LIFE RETORT POUCHES SENSORY ANALYSIS OXYGEN CRACKERS PACKAGING SENSORY... Packaging for MRE. (a) MRE Retort Pouch Quad-Laminate Structure; (b) MRE Non- retort Pouch Tri-Laminate Structure

  8. Condition Assessment of Ferrous Water Transmission and Distribution Systems State of Technology Review Report

    Science.gov (United States)

    This White Paper was developed to serve as the basis for discussion at a Technology Forum on Condition Assessment of Water Transmission and Distribution Systems that was held on September 9 and 10, 2008, at Edison, NJ. It was distributed to the Forum participants for review in a...

  9. 7 CFR 610.12 - Equations for predicting soil loss due to water erosion.

    Science.gov (United States)

    2010-01-01

    .... (a) The equation for predicting soil loss due to erosion for both the USLE and the RUSLE is A = R × K... 22161.) (b) The factors in the USLE equation are: (1) A is the estimation of average annual soil loss in... 7 Agriculture 6 2010-01-01 2010-01-01 false Equations for predicting soil loss due to water...

  10. Measurement of transepidermal water loss in Tanzanian cot-nursed neonates and its relation to postnatal weight loss

    NARCIS (Netherlands)

    Thijs, HFH; Massawe, AW; Okken, A; Coenraads, PJ; Muskiet, FAJ; Huisman, M; Boersma, ER

    In healthy cot-nursed Tanzanian neonates (n = 92, gestation 26-42 weeks) measurements of transepidermal water loss (TEWL) and weight change were performed during the first 24 h after birth at an average ambient humidity of 70% and an environmental temperature of 32 degrees C. Urine production on day

  11. Water Loss Management: Tools and Methods for Developing Countries

    NARCIS (Netherlands)

    Mutikanga, H.E.

    2012-01-01

    Water utilities in developing countries are struggling to provide customers with a reliable level of service due to their peculiar water distribution characteristics including poorly zoned networks with irregular supply operating under restricted budgets. These unique conditions demand unique tools

  12. Water Loss Management : Tools and Methods for Developing Countries

    NARCIS (Netherlands)

    Mutikanga, H.E.

    2012-01-01

    Water utilities in developing countries are struggling to provide customers with a reliable level of service due to their peculiar water distribution characteristics including poorly zoned networks with irregular supply operating under restricted budgets. These unique conditions demand unique tools

  13. A survey of preharvest conditions affecting the regulation of water loss during vase life

    NARCIS (Netherlands)

    Fanourakis, D.; Velez-Ramirez, A.I.; In, B.C.; Barendse, H.; Meeteren, van U.; Woltering, E.J.

    2015-01-01

    Vase life (VL) tests on cut roses obtained from commercial sources were conducted at FloraHolland. Water stress symptoms were the most important criterion terminating VL in 46 out of 50 assessed cultivars. These symptoms appear when water loss exceeds water uptake. Inadequate control of water

  14. A Numerical Study of Water Loss Rate Distributions in MDCT-based Human Airway Models

    Science.gov (United States)

    Wu, Dan; Miyawaki, Shinjiro; Tawhai, Merryn H.; Hoffman, Eric A.; Lin, Ching-Long

    2015-01-01

    Both three-dimensional (3D) and one-dimensional (1D) computational fluid dynamics (CFD) methods are applied to study regional water loss in three multi-detector row computed-tomography (MDCT)-based human airway models at the minute ventilations of 6, 15 and 30 L/min. The overall water losses predicted by both 3D and 1D models in the entire respiratory tract agree with available experimental measurements. However, 3D and 1D models reveal different regional water loss rate distributions due to the 3D secondary flows formed at bifurcations. The secondary flows cause local skewed temperature and humidity distributions on inspiration acting to elevate the local water loss rate; and the secondary flow at the carina tends to distribute more cold air to the lower lobes. As a result, the 3D model predicts that the water loss rate first increases with increasing airway generation, and then decreases as the air approaches saturation, while the 1D model predicts a monotonic decrease of water loss rate with increasing airway generation. Moreover, the 3D (or 1D) model predicts relatively higher water loss rates in lower (or upper) lobes. The regional water loss rate can be related to the non-dimensional wall shear stress (τ*) by the non-dimensional mass transfer coefficient (h0*) as h0* = 1.15 τ*0.272, R = 0.842. PMID:25869455

  15. A review of research progress in air-to-water sound transmission

    International Nuclear Information System (INIS)

    Peng Zhao-Hui; Zhang Ling-Shan

    2016-01-01

    International and domestic research progress in theory and experiment and applications of the air-to-water sound transmission are presented in this paper. Four classical numerical methods of calculating the underwater sound field generated by an airborne source, i.e., the ray theory, the wave solution, the normal-mode theory and the wavenumber integration approach, are introduced. Effects of two special conditions, i.e., the moving airborne source or medium and the rough air-water interface, on the air-to-water sound transmission are reviewed. In experimental studies, the depth and range distributions of the underwater sound field created by different kinds of airborne sources in near-field and far-field, the longitudinal horizontal correlation of underwater sound field and application methods for inverse problems are reviewed. (special topic)

  16. The effect of air flow, panel curvature, and internal pressurization on field-incidence transmission loss. [acoustic propagation through aircraft fuselage

    Science.gov (United States)

    Koval, L. R.

    1975-01-01

    In the context of sound transmission through aircraft fuselage panels, equations for the field-incidence transmission loss (TL) of a single-walled panel are derived that include the effects of external air flow, panel curvature, and internal fuselage pressurization. These effects are incorporated into the classical equations for the TL of single panels, and the resulting double integral for field-incidence TL is numerically evaluated for a specific set of parameters.

  17. [Drinking water regulations in Ukraine and infectious morbidity rate with water pathway of transmission of causative agents].

    Science.gov (United States)

    Surmasheva, E V; Korchak, G I; Mikhienkova, A I; Nikonova, N A; Rosada, M A

    2013-01-01

    These are presented drinking water regulations in Ukraine on microbiological indices in the new state document "Hygienic Drinking water regulations intended for human consumption" (State sanitary regulations and standards (GsanPiN) 2.2.4-171-10). There is reported an analysis of both the open waterbodies water quality and water for centralized water supply in 2007-2011 and 1992-1996 also on sanitary-bacteriological indices for performance of comparative retrospective analysis. There has been shown water quality degradation for open waterbodies, the main sources of water supply for population. Against this background, a marked improvement of drinking water quality has been noted, the number of non-standard samples decreased to 3.6 % compared with 8.8% in the preceding 15 years. This index correlates with a decrease in the number of outbreaks of infections transmitted by water. There was noted unsatisfactory registration of viral infections with water pathway of transmission and the increase in morbidity rate of gastroenterocolitides of unknown etiology that may include acute viral intestinal infections. Expediency to keep "fermentation of glucose" test in bacteriological examination of water in the identification scheme of general coliforms has been substantiated.

  18. Stages in water loss in fruit and vegetables

    Science.gov (United States)

    de Ita, A. Antonio; Flores, Georgina

    2017-01-01

    We analyzes the different stages in the dehydration of fruits and vegetables. It was found to vary from a lettuce: as a sharp drop at low temperature, (arround 150 °C) to five stages in total, with a loss almost continuous to about 300 ° C, such as grapefruit, papaya and fig. The first section in your paper.

  19. Water supply as a constraint on transmission expansion planning in the Western interconnection

    Science.gov (United States)

    Tidwell, Vincent C.; Bailey, Michael; Zemlick, Katie M.; Moreland, Barbara D.

    2016-12-01

    Consideration of water supply in transmission expansion planning (TEP) provides a valuable means of managing impacts of thermoelectric generation on limited water resources. Toward this opportunity, thermoelectric water intensity factors and water supply availability (fresh and non-fresh sources) were incorporated into a recent TEP exercise conducted for the electric interconnection in the Western United States. The goal was to inform the placement of new thermoelectric generation so as to minimize issues related to water availability. Although freshwater availability is limited in the West, few instances across five TEP planning scenarios were encountered where water availability impacted the development of new generation. This unexpected result was related to planning decisions that favored the development of low water use generation that was geographically dispersed across the West. These planning decisions were not made because of their favorable influence on thermoelectric water demand; rather, on the basis of assumed future fuel and technology costs, policy drivers and the topology of electricity demand. Results also projected that interconnection-wide thermoelectric water consumption would increase by 31% under the business-as-usual case, while consumption would decrease by 42% under a scenario assuming a low-carbon future. Except in a few instances, new thermoelectric water consumption could be accommodated with less than 10% of the local available water supply; however, limited freshwater supplies and state-level policies could increase use of non-fresh water sources for new thermoelectric generation. Results could have been considerably different if scenarios favoring higher-intensity water use generation technology or potential impacts of climate change had been explored. Conduct of this exercise highlighted the importance of integrating water into all phases of TEP, particularly joint management of decisions that are both directly (e.g., water

  20. Spent fuel heatup following loss of water during storage

    International Nuclear Information System (INIS)

    Benjamin, A.S.; McCloskey, D.J.

    1978-01-01

    Spent fuel assemblies from light water reactors are typically stored for one year or more in the reactor spent fuel pool and then transported for long-term storage at an off-site location. Because of the design, construction, and operation features of spent fuel storage pools, an accident that might drain most of the water from a pool is assessed as being extremely improbable. As a limiting case, however, a hypothetical incident involving instantaneous draining of all the water from a storage pool has been postulated, and the subsequent heatup of the spent fuel elements has been evaluated. The model is analyzed, and results are summarized

  1. Mycobacterium avium complex--the role of potable water in disease transmission.

    Science.gov (United States)

    Whiley, H; Keegan, A; Giglio, S; Bentham, R

    2012-08-01

    Mycobacterium avium complex (MAC) is a group of opportunistic pathogens of major public health concern. It is responsible for a wide spectrum of disease dependent on subspecies, route of infection and patients pre-existing conditions. Presently, there is limited research on the incidence of MAC infection that considers both pulmonary and other clinical manifestations. MAC has been isolated from various terrestrial and aquatic environments including natural waters, engineered water systems and soils. Identifying the specific environmental sources responsible for human infection is essential in minimizing disease prevalence. This paper reviews current literature and case studies regarding the wide spectrum of disease caused by MAC and the role of potable water in disease transmission. Potable water was recognized as a putative pathway for MAC infection. Contaminated potable water sources associated with human infection included warm water distribution systems, showers, faucets, household drinking water, swimming pools and hot tub spas. MAC can maintain long-term contamination of potable water sources through its high resistance to disinfectants, association with biofilms and intracellular parasitism of free-living protozoa. Further research is required to investigate the efficiency of water treatment processes against MAC and into construction and maintenance of warm water distribution systems and the role they play in MAC proliferation. No claim to Australian Government works Journal of Applied Microbiology © 2012 The Society for Applied Microbiology.

  2. Economic Estimation of the Losses Caused by Surface Water Pollution Accidents in China From the Perspective of Water Bodies' Functions.

    Science.gov (United States)

    Yao, Hong; You, Zhen; Liu, Bo

    2016-01-22

    The number of surface water pollution accidents (abbreviated as SWPAs) has increased substantially in China in recent years. Estimation of economic losses due to SWPAs has been one of the focuses in China and is mentioned many times in the Environmental Protection Law of China promulgated in 2014. From the perspective of water bodies' functions, pollution accident damages can be divided into eight types: damage to human health, water supply suspension, fishery, recreational functions, biological diversity, environmental property loss, the accident's origin and other indirect losses. In the valuation of damage to people's life, the procedure for compensation of traffic accidents in China was used. The functional replacement cost method was used in economic estimation of the losses due to water supply suspension and loss of water's recreational functions. Damage to biological diversity was estimated by recovery cost analysis and damage to environmental property losses were calculated using pollutant removal costs. As a case study, using the proposed calculation procedure the economic losses caused by the major Songhuajiang River pollution accident that happened in China in 2005 have been estimated at 2263 billion CNY. The estimated economic losses for real accidents can sometimes be influenced by social and political factors, such as data authenticity and accuracy. Besides, one or more aspects in the method might be overestimated, underrated or even ignored. The proposed procedure may be used by decision makers for the economic estimation of losses in SWPAs. Estimates of the economic losses of pollution accidents could help quantify potential costs associated with increased risk sources along lakes/rivers but more importantly, highlight the value of clean water to society as a whole.

  3. LOSS OF WATER IN PUBLIC BUILDINGS (ON THE EXAMPLE OF MGSU

    Directory of Open Access Journals (Sweden)

    Orlov Evgeniy Vladimirovich

    2016-09-01

    Full Text Available Any public building is a consumer of water resources. A huge amount of clean drinking water is used for various needs especially in buildings where there are a large number of people, for example, institutions of higher education. It should be noted that today all buildings must meet requirements for water conservation. This is because a large amount of drinking water is wasted. The author considers the problems characteristic of public buildings, because of which losses of water in the inner water supply systems happen. The variants are offered how to reduce wasteful expenses by installing contactless water intake devices, wastewater intake as well as water-saving headers and waterless urinals. The use of polymer materials and copper pipelines during reconstruction of the system in order to reduce water losses is justified.

  4. Comparison of carbon footprints of steel versus concrete pipelines for water transmission.

    Science.gov (United States)

    Chilana, Lalit; Bhatt, Arpita H; Najafi, Mohammad; Sattler, Melanie

    2016-05-01

    The global demand for water transmission and service pipelines is expected to more than double between 2012 and 2022. This study compared the carbon footprint of the two most common materials used for large-diameter water transmission pipelines, steel pipe (SP) and prestressed concrete cylinder pipe (PCCP). A planned water transmission pipeline in Texas was used as a case study. Four life-cycle phases for each material were considered: material production and pipeline fabrication, pipe transportation to the job site, pipe installation in the trench, and operation of the pipeline. In each phase, the energy consumed and the CO2-equivalent emissions were quantified. It was found that pipe manufacturing consumed a large amount of energy, and thus contributed more than 90% of life cycle carbon emissions for both kinds of pipe. Steel pipe had 64% larger CO2-eq emissions from manufacturing compared to PCCP. For the transportation phase, PCCP consumed more fuel due to its heavy weight, and therefore had larger CO2-eq emissions. Fuel consumption by construction equipment for installation of pipe was found to be similar for steel pipe and PCCP. Overall, steel had a 32% larger footprint due to greater energy used during manufacturing. This study compared the carbon footprint of two large-diameter water transmission pipeline materials, steel and prestressed concrete cylinder, considering four life-cycle phases for each. The study provides information that project managers can incorporate into their decision-making process concerning pipeline materials. It also provides information concerning the most important phases of the pipeline life cycle to target for emission reductions.

  5. The impact of water vapor transmission rate on the lifetime of flexible polymer solar cells

    Science.gov (United States)

    Hauch, Jens A.; Schilinsky, Pavel; Choulis, Stelios A.; Rajoelson, Sambatra; Brabec, Christoph J.

    2008-09-01

    In this paper we perform accelerated lifetime testing on high efficiency flexible poly(3-hexylthiophene):[6,6]-phenyl C61 butyric acid methyl ester (P3HT:PCBM) solar cells encapsulated with food package quality barrier films with a water vapor transmission rate of 0.2 g/(m2 day) at 65 °C/85% relative humidity. We show that lifetimes exceeding 1250 h, even at high temperature/high humidity conditions, may be reached, proving that organic solar cells are significantly less sensitive against the environmental effects of water and oxygen than previously expected.

  6. Flow behaviour, suspended sediment transport and transmission losses in a small (sub-bank-full) flow event in an Australian desert stream

    Science.gov (United States)

    Dunkerley, David; Brown, Kate

    1999-08-01

    The behaviour of a discrete sub-bank-full flow event in a small desert stream in western NSW, Australia, is analysed from direct observation and sediment sampling during the flow event and from later channel surveys. The flow event, the result of an isolated afternoon thunderstorm, had a peak discharge of 9 m3/s at an upstream station. Transmission loss totally consumed the flow over the following 7·6 km. Suspended sediment concentration was highest at the flow front (not the discharge peak) and declined linearly with the log of time since passage of the flow front, regardless of discharge variation. The transmission loss responsible for the waning and eventual cessation of flow occurred at a mean rate of 13.2% per km. This is quite rapid, and is more than twice the corresponding figure for bank-full flows estimated by Dunkerley (1992) on the same stream system. It is proposed that transmission losses in ephemeral streams of the kind studied may be minimized in flows near bank-full stage, and be higher in both sub-bank-full and overbank flows. Factors contributing to enhanced flow loss in the sub-bank-full flow studied included abstractions of flow to pools, scour holes and other low points along the channel, and overflow abstractions into channel filaments that did not rejoin the main flow. On the other hand, losses were curtailed by the shallow depth of banks wetted and by extensive mud drapes that were set down over sand bars and other porous channel materials during the flow. Thus, in contrast with the relatively regular pattern of transmission loss inferred from large floods, losses from low flows exhibit marked spatial variability and depend to a considerable extent on streamwise variations in channel geometry, in addition to the depth and porosity of channel perimeter sediments.

  7. Loss of mTOR repressors Tsc1 or Pten has divergent effects on excitatory and inhibitory synaptic transmission in single hippocampal neuron cultures.

    Science.gov (United States)

    Weston, Matthew C; Chen, Hongmei; Swann, John W

    2014-01-01

    The Pten and Tsc1 genes both encode proteins that repress mechanistic target of rapamycin (mTOR) signaling. Disruption of either gene in the brain results in epilepsy and autism-like symptoms in humans and mouse models, therefore it is important to understand the molecular and physiological events that lead from gene disruption to disease phenotypes. Given the similar roles these two molecules play in the regulation of cellular growth and the overlap in the phenotypes that result from their loss, we predicted that the deletion of either the Pten or Tsc1 gene from autaptic hippocampal neurons would have similar effects on neuronal morphology and synaptic transmission. Accordingly, we found that loss of either Pten or Tsc1 caused comparable increases in soma size, dendrite length and action potential properties. However, the effects of Pten and Tsc1 loss on synaptic transmission were different. Loss of Pten lead to an increase in both excitatory and inhibitory neurotransmission, while loss of Tsc1 did not affect excitatory neurotransmission and reduced inhibitory transmission by decreasing mIPSC amplitude. Although the loss of Pten or Tsc1 both increased downstream mTORC1 signaling, phosphorylation of Akt was increased in Pten-ko and decreased in Tsc1-ko neurons, potentially accounting for the different effects on synaptic transmission. Despite the different effects at the synaptic level, our data suggest that loss of Pten or Tsc1 may both lead to an increase in the ratio of excitation to inhibition at the network level, an effect that has been proposed to underlie both epilepsy and autism.

  8. Nutrient losses by wind and water, measurements and modelling

    NARCIS (Netherlands)

    Visser, S.M.; Stroosnijder, L.; Chardon, W.J.

    2005-01-01

    In the Sahelian zone of West-Africa, erosion by both wind and water causes a serious decline in fertility of the already low fertile soils. Despite the fact that the flow of nutrients has been intensively investigated by the use of nutrient balances, little attention has been paid to the

  9. Economic Estimation of the Losses Caused by Surface Water Pollution Accidents in China From the Perspective of Water Bodies’ Functions

    Directory of Open Access Journals (Sweden)

    Hong Yao

    2016-01-01

    Full Text Available The number of surface water pollution accidents (abbreviated as SWPAs has increased substantially in China in recent years. Estimation of economic losses due to SWPAs has been one of the focuses in China and is mentioned many times in the Environmental Protection Law of China promulgated in 2014. From the perspective of water bodies’ functions, pollution accident damages can be divided into eight types: damage to human health, water supply suspension, fishery, recreational functions, biological diversity, environmental property loss, the accident’s origin and other indirect losses. In the valuation of damage to people’s life, the procedure for compensation of traffic accidents in China was used. The functional replacement cost method was used in economic estimation of the losses due to water supply suspension and loss of water’s recreational functions. Damage to biological diversity was estimated by recovery cost analysis and damage to environmental property losses were calculated using pollutant removal costs. As a case study, using the proposed calculation procedure the economic losses caused by the major Songhuajiang River pollution accident that happened in China in 2005 have been estimated at 2263 billion CNY. The estimated economic losses for real accidents can sometimes be influenced by social and political factors, such as data authenticity and accuracy. Besides, one or more aspects in the method might be overestimated, underrated or even ignored. The proposed procedure may be used by decision makers for the economic estimation of losses in SWPAs. Estimates of the economic losses of pollution accidents could help quantify potential costs associated with increased risk sources along lakes/rivers but more importantly, highlight the value of clean water to society as a whole.

  10. Economic Estimation of the Losses Caused by Surface Water Pollution Accidents in China From the Perspective of Water Bodies’ Functions

    Science.gov (United States)

    Yao, Hong; You, Zhen; Liu, Bo

    2016-01-01

    The number of surface water pollution accidents (abbreviated as SWPAs) has increased substantially in China in recent years. Estimation of economic losses due to SWPAs has been one of the focuses in China and is mentioned many times in the Environmental Protection Law of China promulgated in 2014. From the perspective of water bodies’ functions, pollution accident damages can be divided into eight types: damage to human health, water supply suspension, fishery, recreational functions, biological diversity, environmental property loss, the accident’s origin and other indirect losses. In the valuation of damage to people’s life, the procedure for compensation of traffic accidents in China was used. The functional replacement cost method was used in economic estimation of the losses due to water supply suspension and loss of water’s recreational functions. Damage to biological diversity was estimated by recovery cost analysis and damage to environmental property losses were calculated using pollutant removal costs. As a case study, using the proposed calculation procedure the economic losses caused by the major Songhuajiang River pollution accident that happened in China in 2005 have been estimated at 2263 billion CNY. The estimated economic losses for real accidents can sometimes be influenced by social and political factors, such as data authenticity and accuracy. Besides, one or more aspects in the method might be overestimated, underrated or even ignored. The proposed procedure may be used by decision makers for the economic estimation of losses in SWPAs. Estimates of the economic losses of pollution accidents could help quantify potential costs associated with increased risk sources along lakes/rivers but more importantly, highlight the value of clean water to society as a whole. PMID:26805869

  11. Gamma transmission gauge for assay of integral water content in soil

    International Nuclear Information System (INIS)

    Fishman, A.; Notea, A.; Segal, Y.

    1981-01-01

    A photon transmission gauge applied for integral water content measurement in a soil layer was analyzed. The gauge may be used as a control unit for automatic irrigation in a field, or as a scanner employed for establishing an irrigation policy. The characteristic functions of the gauge: response and relative resolving power were developed. The functions provide parameter study at the design stage and interpretational ability at the operational stage. The model led to a design which eliminates sensitivity to water distribution in the examined soil. It is shown that a resolving power of 2% was obtained for a 2.3 mCi 137 Cs source at 53 cm below surface, in measuring water content of 0.2 g water/cm 3 soil during 1000 s. (orig.)

  12. DRINKING WATER CONSUMPTION AND LOSS IN ALGERIA THE CASE OF NETWORKS WITH LOW LEVEL COUNTING

    Directory of Open Access Journals (Sweden)

    Rachid Masmoudi

    2016-01-01

    Full Text Available Demand for drinking domestic water is continuously increasing specially in urban centres which experience high demographic expansion. The decrease of water losses in water supply networks can help preserve such a rare resource. Low number of water meters and intermittent supply make it difficult to quantify the leaking volumes of water. This article presents an analysis of the consumption for drinking water based on an extrapolation from a sample of consumers on whom data are available. Comparison of the volumes of water produced allows a determination of the losses in the water supply system. This analysis is completed by measurements of night flows. The results obtained may be relied on for an evaluation of the needs for drinking water in the South of Algeria, and for future regional development. The study indicates a high rate of water losses in the distribution network, reaching about 40%, and over-consumption due to an insufficient number of water meters and discontinuous supply. It is recommended that water meters come into general use and defective parts of the network are rehabilitated. We will try then to make the necessary recommendations in order to better functioning of the water supply systems in Algeria.

  13. Metabolic rate and evaporative water loss of Mexican Spotted and Great Horned Owls

    Science.gov (United States)

    Joseph L. Ganey; Russell P. Balda; Rudy M. King

    1993-01-01

    We measured rates of oxygen consumption and evaporative water loss (EWL) of Mexican Spotted (Strix occidentalis lucida) and Great Horned (Bubo virginianus) owls in Arizona. Basal metabolic rate averaged 0.84 ccO2. g-1. h-1...

  14. Loss of the CNA I secured river water system: analysis and effect evaluation

    International Nuclear Information System (INIS)

    Berra, Sandra; Guala, Mariana I.; Lorenzo, Andrea T.; Raffo Calderon, Maria C.; Urrutia, Guillermo

    1999-01-01

    In this work the evolution of the plant parameters is evaluated in the case of a loss of the secured circuit of river water (system UK). In particular the systems which are affected for this loss were studied. It was evaluated the functional degradation of these systems. (author)

  15. [Effects of strip planting and fallow rotation on the soil and water loss and water use efficiency of slope farmland].

    Science.gov (United States)

    Hou, Xian-Qing; Li, Rong; Han, Qing-Fang; Jia, Zhi-Kuan; Wang, Wei; Yan, Bo; Yang, Bao-Ping

    2012-08-01

    In order to enhance the soil water-retaining capacity of slope farmland and reduce its soil and water loss, a field study was conducted in 2007-2010 to examine the effects of strip planting and fallow rotation on the soil water regime, soil and water loss characteristics, and water use efficiency of a 10 degrees-15 degrees slope farmland in the arid area of southern Ningxia, Northwest China. Compared with the traditional no-strip planting, strip planting and fallow rotation increased the soil water content in 0-200 cm layer significantly, with an increment of 4.9% -7.0%. Strip planting and fallow rotation pattern could also effectively conserve the soil water in rain season, and obviously improve the soil water regime at crops early growth stages. As compared to no-strip planting, strip planting and fallow rotation increased the soil water content in 0-200 cm layer by 5.4%-8.5%, decreased the surface runoff by 0.7-3.2 m3 x hm(-2), sediment runoff by 0.2-1.9 t x hm(-2), and soil total N loss by 42.1% -73.3%, while improved the crop water use efficiency by 6.1% -24.9% and the precipitation use efficiency by 6.3% -15.3%.

  16. SOUND TRANSMISSION LOSS OF A DOUBLE-LEAF SOLID-MICROPERFORATED PARTITION UNDER NORMAL INCIDENCE OF ACOUSTIC LOADING

    Directory of Open Access Journals (Sweden)

    Ahmad Yusuf Ismail

    2011-12-01

    Full Text Available 0 0 1 332 1894 International Islamic University 15 4 2222 14.0 Normal 0 false false false EN-US JA X-NONE /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-priority:99; mso-style-parent:""; mso-padding-alt:0cm 5.4pt 0cm 5.4pt; mso-para-margin:0cm; mso-para-margin-bottom:.0001pt; mso-pagination:widow-orphan; font-size:11.0pt; font-family:"Times New Roman";} The micro-perforated panel (MPP is recently well-known as an alternative ‘green‘ sound absorber replacing the conventional porous materials. Constructed from a solid panel which provides a non-abrassive structure and also an optically attractive surface, there gives a feasibility to implement such a panel inside a vehicle cabin. This paper is the preliminary study to investigate the sound transmission loss (TL of a solid panel coupled with a micro-perforated panel to form a doube-leaf partition which is already known as a lightweigth stucture for noise insulation in vehicles and buildings. The mathematical model for the TL subjected to normal incidence of acoustic excitation is derived. The results show that its performance substantially improves at the troublesome frequency of mass-air-mass resonance which occurs in the conventional double-leaf solid partition. This is important particularly for the noise source predominant at low frequencies. This can also be controlled by tuning the hole size and number as well as the air gap between the panels.  ABSTRAK: Panel bertebuk mikro (micro-perforated panel (MPP kebelakangan ini dikenali sebagai alternatif penyerap bunyi yang mesra alam menggantikan bahan berliang lazim. Dibina daripada satu panel padu yang memberikan satu struktur tak lelas dan juga satu permukaan yang menarik, ia memberikan kemungkinan penggunaan panel tersebut di dalam kabin kenderaan. Tesis ini merupakan kajian permulaan dalam mengkaji hilang pancaran bunyi

  17. Acoustic Transmission Loss and Prolonged Coda Durations of Seismic Airgunning at Intermediate Ranges in the Lau Back-Arc Basin

    Science.gov (United States)

    Scheip, C.; Bohnenstiehl, D. R.; Matsumoto, H.; Dziak, R. P.; Lau, T. A.; Fowler, M.; Conder, J. A.; Wiens, D. A.

    2010-12-01

    During January-February of 2009, the R/V Marcus G. Langseth carried out an active-source seismic survey in the Lau Back-Arc Basin (20 S, 175 W) [Dunn et al., OS13A-1157, 2009]. Although the survey was designed to image sub-seafloor structures, the acoustic energy also was recorded by an array of seven autonomous underwater hydrophones positioned at a range of 29-416 km. The seismic survey used a 36-gun array with a source depth less than 10 m, and fired approximately 9400 shots. The hydrophone receivers were calibrated omni-directional sensors sampled at 250 Hz and moored at a depth of 1000 m. The acoustic environment of the tropical Lau Basin is unique in that the critical depth of the sound channel lies well below the relatively shallow (2000-2500 m) depth of the seafloor. Consequently, sound channel propagation is everywhere bottom limited. The initial arrival of each airgun pulse shows a short rise time, often less than two seconds from initial arrival to peak amplitude; however the coda duration often exceeds sixty seconds. This can be attributed to multipath propagation and seafloor scattering during multiple reflections from the seafloor. Moreover, received level (rms re 1uPa at 1m) versus range data indicate a transmission loss greater than 20log(range), thus exceeding the prediction for a purely spherical spreading model. This also is explained by strong interaction with the seafloor in this bottom-limited setting. The purpose of this paper is to quantify received signal characteristics of the airgun shots and compare predicted variability from numerical models with the observed variability. The results will improve source level estimates for volcanic and tectonic signals within the Lau Basin. They also will be used to assess the possible environmental impacts of further active-source seismic work in bottom-limited settings.

  18. An analysis of ground shaking and transmission loss from infra sound generated by the 2011 Tohoku earthquake

    International Nuclear Information System (INIS)

    Walker, Kristoffer T.; Le Pichon, Alexis; Tae Sung Kim; Il-Young Che; Groot-Hedlin, Catherine de; Garces, Milton

    2013-01-01

    The 2011 Mw 9.0 Tohoku earthquake generated infra sound that was recorded by nine infrasonic arrays. Most arrays recorded a back azimuth variation with time due to the expanse of the source region. We use ray tracing to predict group velocities and back azimuth wind corrections. A Japan accelerometer network recorded ground shaking in unprecedented spatial resolution. We back projected infra sound from arrays IS44 (Kamchatka) and IS30 (Tokyo) to the source region and compare these results with acceleration data. IS44 illuminates the complex geometry of land areas that experienced shaking. IS30 illuminates two volcanoes and a flat area around the city of Sendai, where the maximum accelerations occurred. The arrays and epicentral region define three source-receiver profiles. The observed broadband energy transmission loss (TL) follows an exponential decay law. The best fitting model, which has parameters that are interpreted to include the effects of geometric spreading, scattering, and the maximum ratio of the effective sound speed in the stratosphere to that at the ground (accounts for stratospheric wind speed), yields a 65% variance reduction relative to predictions from a traditional TL relationship. This model is a simplified version of the model of Le Pichon et al. (2012), which yields an 83% variance reduction for a single frequency, implying that fine-scale atmospheric structure is required to explain the TL for stratospheric upwind propagation. Our results show that infrasonic arrays are sensitive to ground acceleration in the source region of mega-thrust earthquakes. The TL results may improve infrasonic amplitude scaling laws for explosive yield. (authors)

  19. Reducing phosphorus loss in tile water with managed drainage in a claypan soil.

    Science.gov (United States)

    Nash, Patrick R; Nelson, Kelly A; Motavalli, Peter P; Nathan, Manjula; Dudenhoeffer, Chris

    2015-03-01

    Installing subsurface tile drain systems in poorly drained claypan soils to improve corn ( L.) yields could potentially increase environmental phosphorus (P) loss through the tile drainage system. The objectives of the study were to quantify the average concentration and loss of ortho-P in tile drain water from a claypan soil and to determine whether managed subsurface drainage (MD) could reduce ortho-P loss in tile water compared with free subsurface drainage (FD). Flow-weighted ortho-P concentration in the tile water was significantly lower with MD (0.09 mg L) compared with that of FD (0.15 mg L). Ortho-P loss in the tile water of this study was reduced with MD (36 g ha) by 80% compared with FD (180 g ha). Contrary to previous research, reduced ortho-P loss observed over the 4-yr study was not solely due to the reduced amount of water drained annually (63%) with MD compared with FD. During the spring period, when flow was similar between MD and FD, the concentration of ortho-P in the tile water generally was lower with MD compared with FD, which resulted in significantly less ortho-P loss with MD. We speculate that MD's ability to conserve water during the dry summer months increased corn's uptake of water and P, which reduced the amount of P available for leaching loss in the subsequent springs. Copyright © by the American Society of Agronomy, Crop Science Society of America, and Soil Science Society of America, Inc.

  20. Surface self-potential patterns related to transmissive fracture trends during a water injection test

    Science.gov (United States)

    DesRoches, A. J.; Butler, K. E.; MacQuarrie, K. TB

    2018-03-01

    Variations in self-potential (SP) signals were recorded over an electrode array during a constant head injection test in a fractured bedrock aquifer. Water was injected into a 2.2 m interval isolated between two inflatable packers at 44 m depth in a vertical well. Negative SP responses were recorded on surface corresponding to the start of the injection period with strongest magnitudes recorded in electrodes nearest the well. SP response decreased in magnitude at electrodes further from the well. Deflation of the packer system resulted in a strong reversal in the SP signal. Anomalous SP patterns observed at surface at steady state were found to be aligned with dominant fracture strike orientations found within the test interval. Numerical modelling of fluid and current flow within a simplified fracture network showed that azimuthal patterns in SP are mainly controlled by transmissive fracture orientations. The strongest SP gradients occur parallel to hydraulic gradients associated with water flowing out of the transmissive fractures into the tighter matrix and other less permeable cross-cutting fractures. Sensitivity studies indicate that increasing fracture frequency near the well increases the SP magnitude and enhances the SP anomaly parallel to the transmissive set. Decreasing the length of the transmissive fractures leads to more fluid flow into the matrix and into cross-cutting fractures proximal to the well, resulting in a more circular and higher magnitude SP anomaly. Results from the field experiment and modelling provide evidence that surface-based SP monitoring during constant head injection tests has the ability to identify groundwater flow pathways within a fractured bedrock aquifer.

  1. Buoyancy driven flow in a hot water tank due to standby heat loss

    DEFF Research Database (Denmark)

    Fan, Jianhua; Furbo, Simon

    2012-01-01

    Results of experimental and numerical investigations of thermal behavior in a vertical cylindrical hot water tank due to standby heat loss of the tank are presented. The effect of standby heat loss on temperature distribution in the tank is investigated experimentally on a slim 150l tank...... show that the CFD model predicts satisfactorily water temperatures at different levels of the tank during cooling by standby heat loss. It is elucidated how the downward buoyancy driven flow along the tank wall is established by the heat loss from the tank sides and how the natural convection flow...... with a height to diameter ratio of 5. A tank with uniform temperatures and with thermal stratification is studied. A detailed computational fluid dynamics (CFD) model of the tank is developed to calculate the natural convection flow in the tank. The distribution of the heat loss coefficient for the different...

  2. Water loss in table grapes: model development and validation under dynamic storage conditions

    Directory of Open Access Journals (Sweden)

    Ericsem PEREIRA

    2017-09-01

    Full Text Available Abstract Water loss is a critical problem affecting the quality of table grapes. Temperature and relative humidity (RH are essential in this process. Although mathematical modelling can be applied to measure constant temperature and RH impacts, it is proved that variations in storage conditions are normally encountered in the cold chain. This study proposed a methodology to develop a weight loss model for table grapes and validate its predictions in non-constant conditions of a domestic refrigerator. Grapes were maintained under controlled conditions and the weight loss was measured to calibrate the model. The model described the water loss process adequately and the validation tests confirmed its predictive ability. Delayed cooling tests showed that estimated transpiration rates in subsequent continuous temperature treatment was not significantly influenced by prior exposure conditions, suggesting that this model may be useful to estimate the weight loss consequences of interruptions in the cold chain.

  3. The Influence of Water and Mineral Oil On Volumetric Losses in a Hydraulic Motor

    Directory of Open Access Journals (Sweden)

    Śliwiński Pawel

    2017-04-01

    Full Text Available In this paper volumetric losses in hydraulic motor supplied with water and mineral oil (two liquids having significantly different viscosity and lubricating properties are described and compared. The experimental tests were conducted using an innovative hydraulic satellite motor, that is dedicated to work with different liquids, including water. The sources of leaks in this motor are also characterized and described. On this basis, a mathematical model of volumetric losses and model of effective rotational speed have been developed and presented. The results of calculation of volumetric losses according to the model are compared with the results of experiment. It was found that the difference is not more than 20%. Furthermore, it has been demonstrated that this model well describes in both the volumetric losses in the motor supplied with water and oil. Experimental studies have shown that the volumetric losses in the motor supplied with water are even three times greater than the volumetric losses in the motor supplied with oil. It has been shown, that in a small constant stream of water the speed of the motor is reduced even by half in comparison of speed of motor supplied with the same stream of oil.

  4. How Does Tree Density Affect Water Loss of Peatlands? A Mesocosm Experiment

    NARCIS (Netherlands)

    Limpens, J.; Holmgren, M.; Jacobs, C.M.J.; Zee, van der S.E.A.T.M.; Karofeld, E.; Berendse, F.

    2014-01-01

    Raised bogs have accumulated more atmospheric carbon than any other terrestrial ecosystem on Earth. Climate-induced expansion of trees and shrubs may turn these ecosystems from net carbon sinks into sources when associated with reduced water tables. Increasing water loss through tree

  5. Apparent losses due to domestic water meter under-registration in ...

    African Journals Online (AJOL)

    2015-10-05

    Oct 5, 2015 ... water in terms of volume, but 69% in terms of financial loss to the utility ... trative errors to vary between 2% and 10% of billed metered consumption. ... important from a water management perspective, but fell out- side the ...

  6. Apparent losses due to domestic water meter under-registration in ...

    African Journals Online (AJOL)

    By combining these results with the average age of meters in South Africa, estimated from the National Water Demand Archive, it was possible to estimate the average meter under-registration due to meter aging. The study concluded that apparent losses due to water meter under-registration are around 5% of consumption ...

  7. Hydric "Costs" of Reproduction: Pregnancy Increases Evaporative Water Loss in the Snake Vipera aspis.

    Science.gov (United States)

    Lourdais, Olivier; Dupoué, Andréaz; Guillon, Michaël; Guiller, Gaëtan; Michaud, Bruno; DeNardo, Dale F

    Water constraints can mediate evolutionary conflict either among individuals (e.g., parent-offspring conflict, sexual conflict) or within an individual (e.g., cost of reproduction). During pregnancy, water is of particular importance because the female provides all water needed for embryonic development and experiences important maternal shifts in behavior and physiology that, together, can compromise female water balance if water availability is limited. We examined the effect of pregnancy on evaporative water loss and microhabitat selection in a viviparous snake, the aspic viper. We found that both physiological (increased metabolism and body temperature) and morphological (body distension) changes contribute to an increased evaporative water loss in pregnant females. We also found that pregnant females in the wild select warmer and moister basking locations than nonreproductive females, likely to mitigate the conflict between thermal needs and water loss. Water resources likely induce significant reproductive constraints across diverse taxa and thus warrant further consideration in ecological research. From an evolutionary perspective, water constraints during reproduction may contribute to shaping reproductive effort.

  8. Water loss from terrestrial planets with CO{sub 2}-rich atmospheres

    Energy Technology Data Exchange (ETDEWEB)

    Wordsworth, R. D.; Pierrehumbert, R. T., E-mail: rwordsworth@uchicago.edu [Department of the Geophysical Sciences, University of Chicago, 60637 IL (United States)

    2013-12-01

    Water photolysis and hydrogen loss from the upper atmospheres of terrestrial planets is of fundamental importance to climate evolution but remains poorly understood in general. Here we present a range of calculations we performed to study the dependence of water loss rates from terrestrial planets on a range of atmospheric and external parameters. We show that CO{sub 2} can only cause significant water loss by increasing surface temperatures over a narrow range of conditions, with cooling of the middle and upper atmosphere acting as a bottleneck on escape in other circumstances. Around G-stars, efficient loss only occurs on planets with intermediate CO{sub 2} atmospheric partial pressures (0.1-1 bar) that receive a net flux close to the critical runaway greenhouse limit. Because G-star total luminosity increases with time but X-ray and ultraviolet/ultravoilet luminosity decreases, this places strong limits on water loss for planets like Earth. In contrast, for a CO{sub 2}-rich early Venus, diffusion limits on water loss are only important if clouds caused strong cooling, implying that scenarios where the planet never had surface liquid water are indeed plausible. Around M-stars, water loss is primarily a function of orbital distance, with planets that absorb less flux than ∼270 W m{sup –2} (global mean) unlikely to lose more than one Earth ocean of H{sub 2}O over their lifetimes unless they lose all their atmospheric N{sub 2}/CO{sub 2} early on. Because of the variability of H{sub 2}O delivery during accretion, our results suggest that many 'Earth-like' exoplanets in the habitable zone may have ocean-covered surfaces, stable CO{sub 2}/H{sub 2}O-rich atmospheres, and high mean surface temperatures.

  9. Thermal stratification in a hot water tank established by heat loss from the tank

    DEFF Research Database (Denmark)

    Fan, Jianhua; Furbo, Simon

    2012-01-01

    This paper presents numerical investigations of thermal stratification in a vertical cylindrical hot water tank established by standby heat loss from the tank. The transient fluid flow and heat transfer in the tank during cooling caused by standby heat loss are calculated by means of validated...... computational fluid dynamics (CFD) models. The measured heat loss coefficient for the different parts of the tank is used as input to the CFD model. Parametric studies are carried out using the validated models to investigate the influence on thermal stratification of the tank by the downward flow...... the heat loss from the tank sides will be distributed at different levels of the tank at different thermal conditions. The results show that 20–55% of the side heat loss drops to layers below in the part of the tank without the presence of thermal stratification. A heat loss removal factor is introduced...

  10. Quantitative nanoscale water mapping in frozen-hydrated skin by low-loss electron energy-loss spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Yakovlev, Sergey [Department of Chemical Engineering and Materials Science, Stevens Institute of Technology, Hoboken, NJ 07030 (United States); Misra, Manoj; Shi, Shanling [Unilever Research and Development, Trumbull, CT 06611 (United States); Firlar, Emre [Department of Chemical Engineering and Materials Science, Stevens Institute of Technology, Hoboken, NJ 07030 (United States); Libera, Matthew, E-mail: mlibera@stevens.edu [Department of Chemical Engineering and Materials Science, Stevens Institute of Technology, Hoboken, NJ 07030 (United States)

    2010-06-15

    Spatially resolved low-loss electron energy-loss spectroscopy (EELS) is a powerful method to quantitatively determine the water distribution in frozen-hydrated biological materials at high spatial resolution. However, hydrated tissue, particularly its hydrophilic protein-rich component, is very sensitive to electron radiation. This sensitivity has traditionally limited the achievable spatial resolution because of the relatively high noise associated with low-dose data acquisition. We show that the damage caused by high-dose data acquisition affects the accuracy of a multiple-least-squares (MLS) compositional analysis because of inaccuracies in the reference spectrum used to represent the protein. Higher spatial resolution combined with more accurate compositional analysis can be achieved if a reference spectrum is used that better represents the electron-beam-damaged protein component under frozen-hydrated conditions rather than one separately collected from dry protein under low-dose conditions. We thus introduce a method to extract the best-fitting protein reference spectrum from an experimental spectrum dataset. This method can be used when the MLS-fitting problem is sufficiently constrained so that the only unknown is the reference spectrum for the protein component. We apply this approach to map the distribution of water in cryo-sections obtained from frozen-hydrated tissue of porcine skin. The raw spectral data were collected at doses up to 10{sup 5} e/nm{sup 2} despite the fact that observable damage begins at doses as low as 10{sup 3} e/nm{sup 2}. The resulting spatial resolution of 10 nm is 5-10 times better than that in previous studies of frozen-hydrated tissue and is sufficient to resolve sub-cellular water fluctuations as well as the inter-cellular lipid-rich regions of skin where water-mediated processes are believed to play a significant role in the phenotype of keratinocytes in the stratum corneum.

  11. Quantitative nanoscale water mapping in frozen-hydrated skin by low-loss electron energy-loss spectroscopy

    International Nuclear Information System (INIS)

    Yakovlev, Sergey; Misra, Manoj; Shi, Shanling; Firlar, Emre; Libera, Matthew

    2010-01-01

    Spatially resolved low-loss electron energy-loss spectroscopy (EELS) is a powerful method to quantitatively determine the water distribution in frozen-hydrated biological materials at high spatial resolution. However, hydrated tissue, particularly its hydrophilic protein-rich component, is very sensitive to electron radiation. This sensitivity has traditionally limited the achievable spatial resolution because of the relatively high noise associated with low-dose data acquisition. We show that the damage caused by high-dose data acquisition affects the accuracy of a multiple-least-squares (MLS) compositional analysis because of inaccuracies in the reference spectrum used to represent the protein. Higher spatial resolution combined with more accurate compositional analysis can be achieved if a reference spectrum is used that better represents the electron-beam-damaged protein component under frozen-hydrated conditions rather than one separately collected from dry protein under low-dose conditions. We thus introduce a method to extract the best-fitting protein reference spectrum from an experimental spectrum dataset. This method can be used when the MLS-fitting problem is sufficiently constrained so that the only unknown is the reference spectrum for the protein component. We apply this approach to map the distribution of water in cryo-sections obtained from frozen-hydrated tissue of porcine skin. The raw spectral data were collected at doses up to 10 5 e/nm 2 despite the fact that observable damage begins at doses as low as 10 3 e/nm 2 . The resulting spatial resolution of 10 nm is 5-10 times better than that in previous studies of frozen-hydrated tissue and is sufficient to resolve sub-cellular water fluctuations as well as the inter-cellular lipid-rich regions of skin where water-mediated processes are believed to play a significant role in the phenotype of keratinocytes in the stratum corneum.

  12. Building America Case Study: Addressing Multifamily Piping Losses with Solar Hot Water, Davis, California

    Energy Technology Data Exchange (ETDEWEB)

    2016-12-01

    Solar thermal water heating is most cost effective when applied to multifamily buildings and some states offer incentives or other inducements to install them. However, typical solar water heating designs do not allow the solar generated heat to be applied to recirculation losses, only to reduce the amount of gas or electric energy needed for hot water that is delivered to the fixtures. For good reasons, hot water that is recirculated through the building is returned to the water heater, not to the solar storage tank. The project described in this report investigated the effectiveness of using automatic valves to divert water that is normally returned through the recirculation piping to the gas or electric water heater instead to the solar storage tank. The valves can be controlled so that the flow is only diverted when the returning water is cooler than the water in the solar storage tank.

  13. Using Solar Hot Water to Address Piping Heat Losses in Multifamily Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Springer, David [Alliance for Residential Building Innovation, Davis, CA (United States); Seitzler, Matt [Alliance for Residential Building Innovation, Davis, CA (United States); Backman, Christine [Alliance for Residential Building Innovation, Davis, CA (United States); Weitzel, Elizabeth [Alliance for Residential Building Innovation, Davis, CA (United States)

    2015-10-01

    Solar thermal water heating is most cost effective when applied to multifamily buildings and some states offer incentives or other inducements to install them. However, typical solar water heating designs do not allow the solar generated heat to be applied to recirculation losses, only to reduce the amount of gas or electric energy needed for hot water that is delivered to the fixtures. For good reasons, hot water that is recirculated through the building is returned to the water heater, not to the solar storage tank. The project described in this report investigated the effectiveness of using automatic valves to divert water that is normally returned through the recirculation piping to the gas or electric water heater instead to the solar storage tank. The valves can be controlled so that the flow is only diverted when the returning water is cooler than the water in the solar storage tank.

  14. Body ion loss as a bioindicator of water quality impaired by coal mining

    International Nuclear Information System (INIS)

    Grippo, R.S.; Dunson, W.A.

    1994-01-01

    Protection of surface waters receiving discharges from coal mines is currently based on performance standards set by the EPA after passage of the Clean Water Act. These standards were technology-driven and reflect the Best Achievable Control Technology (BAT) available at the time of promulgation. Changes proposed as part of the upcoming reauthorization of the US Clean Water Act suggest that such technology-based standards may be reevaluated in light of more recent information on the toxicological effect of mine discharges on aquatic biota. The authors present here a physiological-based method for evaluating the site-specific toxicity of mine-derived discharges into receiving waters. They tested the usefulness of the body ion loss rate bioassay by exposing fathead minnows, brook charr and stoneflies to coal mine-impacted waters (elevated acidity and trace metals) in the field and to artificial mine water (AMW) in the laboratory. Body ion loss rate was significantly correlated with levels of mine pollution in the field. Body ion loss measured in AMW revealed strong interactions between metals and acid. Because the test animals exhibited differing levels of sensitivity to mine discharge, the selection of an appropriate organism for the body ion loss bioassay may vary depending on the (1) physical characteristics, (2) chemical characteristics and (3) pre-existing level of mine impact of the receiving waters

  15. Fruit cuticle lipid composition and fruit post-harvest water loss in an advanced backcross generation of pepper (Capsicum sp.)

    KAUST Repository

    Parsons, Eugene P.; Popopvsky, Sigal; Lohrey, Gregory T.; Lu, Shiyou; Alkalai-Tuvia, Sharon; Perzelan, Yaacov; Paran, Ilan; Fallik, Elazar; Jenks, Matthew A.

    2012-01-01

    To understand the role of fruit cuticle lipid composition in fruit water loss, an advanced backcross population, the BC2F2, was created between the Capsicum annuum (PI1154) and the Capsicum chinense (USDA162), which have high and low post-harvest water loss rates, respectively. Besides dramatic differences in fruit water loss, preliminary studies also revealed that these parents exhibited significant differences in both the amount and composition of their fruit cuticle. Cuticle analysis of the BC2F2 fruit revealed that although water loss rate was not strongly associated with the total surface wax amount, there were significant correlations between water loss rate and cuticle composition. We found a positive correlation between water loss rate and the amount of total triterpenoid plus sterol compounds, and negative correlations between water loss and the alkane to triterpenoid plus sterol ratio. We also report negative correlations between water loss rate and the proportion of both alkanes and aliphatics to total surface wax amount. For the first time, we report significant correlations between water loss and cutin monomer composition. We found positive associations of water loss rate with the total cutin, total C16 monomers and 16-dihydroxy hexadecanoic acid. Our results support the hypothesis that simple straight-chain aliphatic cuticle constituents form more impermeable cuticular barriers than more complex isoprenoid-based compounds. These results shed new light on the biochemical basis for cuticle involvement in fruit water loss. © 2012 Physiologia Plantarum.

  16. Fruit cuticle lipid composition and fruit post-harvest water loss in an advanced backcross generation of pepper (Capsicum sp.)

    KAUST Repository

    Parsons, Eugene P.

    2012-03-05

    To understand the role of fruit cuticle lipid composition in fruit water loss, an advanced backcross population, the BC2F2, was created between the Capsicum annuum (PI1154) and the Capsicum chinense (USDA162), which have high and low post-harvest water loss rates, respectively. Besides dramatic differences in fruit water loss, preliminary studies also revealed that these parents exhibited significant differences in both the amount and composition of their fruit cuticle. Cuticle analysis of the BC2F2 fruit revealed that although water loss rate was not strongly associated with the total surface wax amount, there were significant correlations between water loss rate and cuticle composition. We found a positive correlation between water loss rate and the amount of total triterpenoid plus sterol compounds, and negative correlations between water loss and the alkane to triterpenoid plus sterol ratio. We also report negative correlations between water loss rate and the proportion of both alkanes and aliphatics to total surface wax amount. For the first time, we report significant correlations between water loss and cutin monomer composition. We found positive associations of water loss rate with the total cutin, total C16 monomers and 16-dihydroxy hexadecanoic acid. Our results support the hypothesis that simple straight-chain aliphatic cuticle constituents form more impermeable cuticular barriers than more complex isoprenoid-based compounds. These results shed new light on the biochemical basis for cuticle involvement in fruit water loss. © 2012 Physiologia Plantarum.

  17. Concentration dependence of transmission losses in UV-laser irradiated bovine α-, βH-, βL- and γ-crystallin solutions

    International Nuclear Information System (INIS)

    Hott, J.L.; Borkman, R.F.

    1993-01-01

    Experiments with calf lens protein fractions in aqueous buffer solutions at room temperature showed that β H -, β L - and γ-crystallin fractions became opaque following ultraviolet exposure at 308 nm, while the α-crystallin fraction remained transparent. Transmission loss, due to UV-irradiation, for all of the crystallin samples was studied in the concentration range of 0.1 mg/mL to 1.0 mg/mL, and for α- and γ-crystallin, in the range up to 5 mg/mL. With increased concentrations of β H -, β L -and γ-crystalline, the rate of opacification increased. However, with α-crystallin, the loss of transmission was negligible for all of the concentrations and irradiation times studied. Opacification of the crystallins was accompanied by formation of higher molecular weight insoluble proteins as detected by SDS-PAGE. (Author)

  18. Climate change reduces water availability for agriculture by decreasing non-evaporative irrigation losses

    Science.gov (United States)

    Malek, Keyvan; Adam, Jennifer C.; Stöckle, Claudio O.; Peters, R. Troy

    2018-06-01

    Irrigation efficiency plays an important role in agricultural productivity; it affects farm-scale water demand, and the partitioning of irrigation losses into evaporative and non-evaporative components. This partitioning determines return flow generation and thus affects water availability. Over the last two decades, hydrologic and agricultural research communities have significantly improved our understanding of the impacts of climate change on water availability and food productivity. However, the impacts of climate change on the efficiency of irrigation systems, particularly on the partitioning between evaporative and non-evaporative losses, have received little attention. In this study, we incorporated a process-based irrigation module into a coupled hydrologic/agricultural modeling framework (VIC-CropSyst). To understand how climate change may impact irrigation losses, we applied VIC-CropSyst over the Yakima River basin, an important agricultural region in Washington State, U.S. We compared the historical period of 1980-2010 to an ensemble of ten projections of climate for two future periods: 2030-2060 and 2060-2090. Results averaged over the watershed showed that a 9% increase in evaporative losses will be compensated by a reduction of non-evaporative losses. Therefore, overall changes in future efficiency are negligible (-0.4%) while the Evaporative Loss Ratio (ELR) (defined as the ratio of evaporative to non-evaporative irrigation losses) is enhanced by 10%. This higher ELR is associated with a reduction in return flows, thus negatively impacting downstream water availability. Results also indicate that the impact of climate change on irrigation losses depend on irrigation type and climate scenarios.

  19. Effect of slope and plant cover on run-off, soil loss and water use ...

    African Journals Online (AJOL)

    An average of 6,2t/ha soil loss and 80,6% run-off of the amount of water applied occurred from the pioneer veld (0,7% basal cover) on the steepest slope. In all the successional stages more run-off and less soil loss occurred from wet soil than from dry soil. Significant (P<0,01) relationships between basal and canopy cover ...

  20. A Temperature-Based Bioimpedance Correction for Water Loss Estimation During Sports.

    Science.gov (United States)

    Ring, Matthias; Lohmueller, Clemens; Rauh, Manfred; Mester, Joachim; Eskofier, Bjoern M

    2016-11-01

    The amount of total body water (TBW) can be estimated based on bioimpedance measurements of the human body. In sports, TBW estimations are of importance because mild water losses can impair muscular strength and aerobic endurance. Severe water losses can even be life threatening. TBW estimations based on bioimpedance, however, fail during sports because the increased body temperature corrupts bioimpedance measurements. Therefore, this paper proposes a machine learning method that eliminates the effects of increased temperature on bioimpedance and, consequently, reveals the changes in bioimpedance that are due to TBW loss. This is facilitated by utilizing changes in skin and core temperature. The method was evaluated in a study in which bioimpedance, temperature, and TBW loss were recorded every 15 min during a 2-h running workout. The evaluation demonstrated that the proposed method is able to reduce the error of TBW loss estimation by up to 71%, compared to the state of art. In the future, the proposed method in combination with portable bioimpedance devices might facilitate the development of wearable systems for continuous and noninvasive TBW loss monitoring during sports.

  1. Time course of cortisol loss in hair segments under immersion in hot water.

    Science.gov (United States)

    Li, Jifeng; Xie, Qiaozhen; Gao, Wei; Xu, Youyun; Wang, Shuang; Deng, Huihua; Lu, Zuhong

    2012-02-18

    Hair cortisol is supposed to be a good biomarker of chronic stress. Major loss of hair cortisol in long-term exposure to environmental factors affected strongly its proper assessment of chronic stress in human. However, there was no research on time course of hair cortisol loss during the long-term exposure. Hair samples with longer than 1cm in the posterior vertex region were cut as close as possible to the scalp. The 1-cm hair samples were treated by ultraviolet irradiation or immersion in shampoo solution or water immersion at 40, 65 and 80°C. Hair cortisol content was determined with high performance liquid chromatography tandem mass spectrometry. Ultraviolet irradiation and immersion in shampoo solution and hot water gave rise to the significant cortisol loss in hair. Hair cortisol content was sharply decreased with water immersion duration during initial stage and slowly decreased in the following stage. The 2-stage loss process with water immersion duration modeled to some extent time course of hair cortisol loss in long-term exposure to external environments. Cortisol from hair samples closest to the scalp in the posterior vertex could represent more accurately central hypothalamo-pituitary-adrenal activity. Copyright © 2011 Elsevier B.V. All rights reserved.

  2. Evaluation of the correlations for predicting evaporative loss from water body

    International Nuclear Information System (INIS)

    Yilmaz, T.P.; Aybar, H.S.

    1999-01-01

    Water evaporation (evaporation from here on) is a natural phenomenon that is important for system design and system safety in many engineering branches. Indeed, evaporative heat and mass loss are observed and calculated in very diverse situations, such as irrigation plants, water purification plants, cooling ponds, lakes, dams, swimming pools, health spas, management of liquid wastes as in evaporation pools, and spent fuel pools in nuclear power plants. There are a number of correlations obtained from experimental studies that predict the evaporative heat and mass loss from a water body. This study aims to summarize and to compare the existing evaporation correlations to determine the upper and lower bounding correlations for use in various thermal-hydraulic analyses of systems. Currently and widely used, six correlations found in the literature have been selected and tested using the major parameters of evaporation such as water temperature, air relative humidity, air velocity, and temperature. The comparison test cases show that ASHRAE (1991) and Ryan et al. (1974) equations result in the highest evaporative loss, while the Brady et al. (1969) equation provides the lowest evaporative loss in most conditions. Engineering designers may sometimes need the upper bound value of evaporative loss or sometimes the lower bound value for a conservative calculation. The authors conclude that using a single equation does not provide the conservative calculation for every situation and show which correlation gives the lower or upper bound for different conditions

  3. Microsporidian species known to infect humans are present in aquatic birds: implications for transmission via water?

    Science.gov (United States)

    Slodkowicz-Kowalska, Anna; Graczyk, Thaddeus K; Tamang, Leena; Jedrzejewski, Szymon; Nowosad, Andrzej; Zduniak, Piotr; Solarczyk, Piotr; Girouard, Autumn S; Majewska, Anna C

    2006-07-01

    Human microsporidiosis, a serious disease of immunocompetent and immunosuppressed people, can be due to zoonotic and environmental transmission of microsporidian spores. A survey utilizing conventional and molecular techniques for examining feces from 570 free-ranging, captive, and livestock birds demonstrated that 21 animals shed microsporidian spores of species known to infect humans, including Encephalitozoon hellem (20 birds; 3.5%) and Encephalitozoon intestinalis (1 bird; 0.2%). Of 11 avian species that shed E. hellem and E. intestinalis, 8 were aquatic birds (i.e., common waterfowl). The prevalence of microsporidian infections in waterfowl (8.6%) was significantly higher than the prevalence of microsporidian infections in other birds (1.1%) (P < 0.03); waterfowl fecal droppings contained significantly more spores (mean, 3.6 x 10(5) spores/g) than nonaquatic bird droppings contained (mean, 4.4 x 10(4) spores/g) (P < 0.003); and the presence of microsporidian spores of species known to infect humans in fecal samples was statistically associated with the aquatic status of the avian host (P < 0.001). We demonstrated that a single visit of a waterfowl flock can introduce into the surface water approximately 9.1 x 10(8) microsporidian spores of species known to infect humans. Our findings demonstrate that waterborne microsporidian spores of species that infect people can originate from common waterfowl, which usually occur in large numbers and have unlimited access to surface waters, including waters used for production of drinking water.

  4. Validation of the surge model and lessons learnt from commissioning of the Shuweihat water transmission scheme, UAE

    NARCIS (Netherlands)

    Leruth, P.; Pothof, I.W.M.; Naja, F.

    2012-01-01

    This paper presents a validation of the surge modeling results as well as lessons learnt from the commissioning test of the Shuweihat Water Transmission Scheme in the UAE. The Scheme is divided in two systems, The first system (Lot A) transmits water from Shuweihat to Mirfa (100 km). The second (Lot

  5. Phosphate dosing of mains water : novel approaches to water loss reduction through leakage detection and policy [abstract

    OpenAIRE

    Ascott, M.J.; Gooddy, D.C.; Lapworth, D.J.; Stuart, M.E.

    2016-01-01

    Detection and t racing of leakage in the environment are essential component s of water loss reduction strategies. Industry standard techniques for tracing leaks include analysis of chlorine and trihalomethane concentrations, but levels of these determinands can fall belo w detection limits due to their volatile nature 1 . Consequently additional tools to trace leakage in the environment are a useful step ...

  6. Method for reducing heat loss during injection of hot water into an oil stratum

    Energy Technology Data Exchange (ETDEWEB)

    Evgenev, A E; Kalashnikov, V N; Raiskii, Yu D

    1968-07-01

    A method is described for reduction of heat loss during the injection of hot water into an oil stratum. During the transportation of the hot water to the face of the bore holes, it has high-molecular polymers added to it. The high-molecular polymer may be guanidine or polyoxyethylene in the quantity of 0.01 to 0.03% by wt.

  7. The effect of fibers on the loss of water by evaporation and shrinkage of concrete

    Directory of Open Access Journals (Sweden)

    N. M. P. Pillar

    Full Text Available Shrinkage is one of the least desirable attributes in concrete. Large areas of exposed concrete surfaces , such as in shotcrete tunnel linings, where it is practically impossible to make a moist cure, are highly susceptible to plastic shrinkage at early ages. The autogenous and drying shrinkage can lead to states of greater than threshold strength, causing fracture, mechanical damage and lack of durability of concrete structures. The addition of fibers can greatly reduce plastic shrinkage, but has limited effect in mitigating autogenous and drying shrinkage. To evaluate the performance of polypropylene and steel fibers to understand their effect on shrinkage of concrete, a study was carried out to relate the loss of water from the paste and the shrinkage during the first 28 days of age, and compare it with a control mix without fiber. The loss of water was obtained by the weight loss of the specimens at different ages, since the only component that could contribute for the loss of weight was the water lost by the paste of the concrete. And the paste itself is the only source of shrinkage. Uniaxial compressive tests from very early ages enabled the determination of time when plastic shrinkage ended. It was observed that the control concrete mix lost three times more water and developed plastic and drying shrinkage 60 % higher than the fiber reinforced concrete mixes. It was possible to demonstrate that the reduced loss of water caused by the incorporation of fibers is related to the mitigation of plastic shrinkage. It was observed that the fibers are effective to restrain the movement of water through the cement paste in the plastic state, however such effect is limited after concrete starts the hardening state.

  8. Intensified water storage loss by biomass burning in Kalimantan: Detection by GRACE

    Science.gov (United States)

    Han, Jiancheng; Tangdamrongsub, Natthachet; Hwang, Cheinway; Abidin, Hasanuddin Z.

    2017-03-01

    Biomass burning is the principal tool for land clearing and a primary driver of land use change in Kalimantan (the Indonesian part of Borneo island). Biomass burning here has consumed millions of hectares of peatland and swamp forests. It also degrades air quality in Southeast Asia, perturbs the global carbon cycle, threatens ecosystem health and biodiversity, and potentially affects the global water cycle. Here we present the optimal estimate of water storage changes over Kalimantan from NASA's Gravity Recovery and Climate Experiment (GRACE). Over August 2002 to December 2014, our result shows a north-south dipole pattern in the long-term changes in terrestrial water storage (TWS) and groundwater storage (GWS). Both TWS and GWS increase in the northern part of Kalimantan, while they decrease in the southern part where fire events are the most severe. The loss rates in TWS and GWS in the southern part are 0.56 ± 0.11 cm yr-1 and 0.55 ± 0.10 cm yr-1, respectively. We use GRACE estimates, burned area, carbon emissions, and hydroclimatic data to study the relationship between biomass burning and water storage losses. The analysis shows that extensive biomass burning results in excessive evapotranspiration, which then increases long-term water storage losses in the fire-prone region of Kalimantan. Our results show the potentials of GRACE and its follow-on missions in assisting water storage and fire managements in a region with extensive biomass burning such as Kalimantan.

  9. Water loss at normal enamel histological points during air drying at room temperature.

    Science.gov (United States)

    De Medeiros, R C G; De Lima, T A S; Gouveia, C R; De Sousa, F B

    2013-06-01

    This in vitro study aimed to quantify water loss at histological points in ground sections of normal enamel during air drying at room temperature (25°C) and relative humidity of 50%. From each of 10 ground sections of erupted permanent human normal enamel, three histological points (n = 30) located at 100, 300 and 500 μm from enamel surface and along a transversal following prisms paths were characterized regarding the mineral, organic and water volumes. Water loss during air drying was from 0 to 48 h. Drying occurred with both falling and constant-drying rates, and drying stabilization times (Teq ) ranged from 0.5 to 11 h with a mean 0.26 (±0.12)% weight loss. In some samples (n = 5; 15 points), Teq increased as a function of the distance from the enamel surface, and drying occurred at an apparent diffusion rate of 3.47 × 10⁻⁸ cm² s⁻¹. Our data provide evidence of air drying resulting in air replacing enamel's loosely bound water in prisms sheaths following a unidirectional water diffusion rate of 3.47 × 10⁻⁸ cm² s⁻¹ (from the original enamel surface inward), not necessarily resulting in water evaporating directly into air, with important implications for transport processes and optical and mechanical properties. © 2013 The Authors Journal of Microscopy © 2013 Royal Microscopical Society.

  10. Li-Ion Pouch Cells for Vehicle Applications — Studies of Water Transmission and Packing Materials

    Directory of Open Access Journals (Sweden)

    Göran Flodberg

    2013-01-01

    Full Text Available This study includes analysis of encapsulation materials from lithium-ion pouch cells and water vapour transmission rate (WVTR measurements. WVTR measurements are performed on both fresh and environmentally stressed lithium-ion pouch cells. Capacity measurements are performed on both the fresh and the environmentally stressed battery cells to identify possible influences on electrochemical performance. Preparation of the battery cells prior to WVTR measurements includes opening of battery cells and extraction of electrode material, followed by resealing the encapsulations and adhesively mounting of gas couplings. A model describing the water diffusion through the thermal welds of the encapsulation are set up based on material analysis of the encapsulation material. Two WVTR equipments with different type of detectors are evaluated in this study. The results from the WVTR measurements show how important it is to perform this type of studies in dry environment and apply a rigorous precondition sequence before testing. Results from modelling confirm that the WVTR method has potential to be used for measurements of water diffusion into lithium-ion pouch cells. Consequently, WVTR measurements should be possible to use as a complement or alternative method to for example Karl Fisher titration.

  11. Measurement of the wetting profile in concrete samples with vertical water by gamma radiation transmission method

    International Nuclear Information System (INIS)

    Silva, L.M. da; Rocha, M.C. da; Appoloni, C.R.; Portezan Filho, O.; Lopes, F.; Melquiades, F.L.; Santos, E.A. dos; Santos, A.O. dos; Moreira, A.C.; Poetker, W.E.; Almeida, E. de; Tannous, C.Q.; Kuramoto, R.; Cavalcante, F.H. de M.; Barbieri, P.F.

    2000-01-01

    Samples of concrete for popular habitation (0,1x0,03x0,1 m) and cellular concrete (0,1x0,05x0,1 m) were submitted to water vertical ascending infiltration. The moisture content spatial and temporal evolution of each sample it was monitored in three halfway positions in a same horizontal line, applying the gamma rays transmission method. The data were taken with a 137 Cs (3,7x10 10 Bq, 0662 MeV) source, NaI (Tl) of 2x2' detector coupled to between wetting profiles and concrete strength. The cellular concrete showed a wetting profile compatible to its greater porosity. (author)

  12. Dynamics of soft Nanomaterials captured by transmission electron microscopy in liquid water

    Energy Technology Data Exchange (ETDEWEB)

    Proetto, Maria T.; Rush, Anthony M.; Chien, Miao-Ping; Abellan Baeza, Patricia; Patterson, Joseph P.; Thompson, Matthew P.; Olson, Norman H.; Moore, Curtis E.; Rheingold, Arnold L.; Andolina, Christopher; Millstone, Jill; Howell, Stephen B.; Browning, Nigel D.; Evans, James E.; Gianneschi, Nathan C.

    2014-01-14

    In this paper we present in situ transmission electron microscopy (TEM) of soft, synthetic nanoparticles with a comparative analysis using conventional TEM methods. This comparison is made with the simple aim of describing what is an unprecedented example of in situ imaging by TEM. However, we contend the technique will quickly become essential in the characterization of analogous systems, especially where dynamics are of interest in the solvated state. In this case, particles were studied which were obtained from the direct polymerization of an oxaliplatin analog, designed for an ongoing program in novel chemotherapeutic delivery systems. The resulting nanoparticles provided sufficient contrast for facile imaging in situ, and point toward key design parameters that enable this new characterization approach for organic nanomaterials. We describe the preparation of the synthetic micellar nanoparticles to- gether with their characterization in liquid water.

  13. Transmission of light in deep sea water at the site of the ANTARES neutrino telescope

    Science.gov (United States)

    ANTARES Collaboration; Aguilar, J. A.; Albert, A.; Amram, P.; Anghinolfi, M.; Anton, G.; Anvar, S.; Ardellier-Desages, F. E.; Aslanides, E.; Aubert, J.-J.; Azoulay, R.; Bailey, D.; Basa, S.; Battaglieri, M.; Becherini, Y.; Bellotti, R.; Beltramelli, J.; Bertin, V.; Billault, M.; Blaes, R.; Blanc, F.; Bland, R. W.; de Botton, N.; Boulesteix, J.; Bouwhuis, M. C.; Brooks, C. B.; Bradbury, S. M.; Bruijn, R.; Brunner, J.; Bugeon, F.; Burgio, G. F.; Cafagna, F.; Calzas, A.; Caponetto, L.; Carmona, E.; Carr, J.; Cartwright, S. L.; Cecchini, S.; Charvis, P.; Circella, M.; Colnard, C.; Compère, C.; Croquette, J.; Cooper, S.; Coyle, P.; Cuneo, S.; Damy, G.; van Dantzig, R.; Deschamps, A.; de Marzo, C.; Destelle, J.-J.; de Vita, R.; Dinkelspiler, B.; Dispau, G.; Drougou, J.-F.; Druillole, F.; Engelen, J.; Favard, S.; Feinstein, F.; Ferry, S.; Festy, D.; Fopma, J.; Fuda, J.-L.; Gallone, J.-M.; Giacomelli, G.; Girard, N.; Goret, P.; Gournay, J.-F.; Hallewell, G.; Hartmann, B.; Heijboer, A.; Hello, Y.; Hernández-Rey, J. J.; Herrouin, G.; Hößl, J.; Hoffmann, C.; Hubbard, J. R.; Jaquet, M.; de Jong, M.; Jouvenot, F.; Kappes, A.; Karg, T.; Karkar, S.; Karolak, M.; Katz, U.; Keller, P.; Kooijman, P.; Korolkova, E. V.; Kouchner, A.; Kretschmer, W.; Kudryavtsev, V. A.; Lafoux, H.; Lagier, P.; Lamare, P.; Languillat, J.-C.; Laubier, L.; Legou, T.; Le Guen, Y.; Le Provost, H.; Le van Suu, A.; Lo Nigro, L.; Lo Presti, D.; Loucatos, S.; Louis, F.; Lyashuk, V.; Magnier, P.; Marcelin, M.; Margiotta, A.; Maron, C.; Massol, A.; Mazéas, F.; Mazeau, B.; Mazure, A.; McMillan, J. E.; Michel, J.-L.; Millot, C.; Milovanovic, A.; Montanet, F.; Montaruli, T.; Morel, J.-P.; Moscoso, L.; Nezri, E.; Niess, V.; Nooren, G. J.; Ogden, P.; Olivetto, C.; Palanque-Delabrouille, N.; Payre, P.; Petta, C.; Pineau, J.-P.; Poinsignon, J.; Popa, V.; Potheau, R.; Pradier, T.; Racca, C.; Randazzo, N.; Real, D.; van Rens, B. A. P.; Réthoré, F.; Ripani, M.; Roca-Blay, V.; Romeyer, A.; Rollin, J.-F.; Romita, M.; Rose, H. J.; Rostovtsev, A.; Ruppi, M.; Russo, G. V.; Sacquin, Y.; Saouter, S.; Schuller, J.-P.; Schuster, W.; Sokalski, I.; Suvorova, O.; Spooner, N. J. C.; Spurio, M.; Stolarczyk, T.; Stubert, D.; Taiuti, M.; Thompson, L. F.; Tilav, S.; Usik, A.; Valdy, P.; Vallage, B.; Vaudaine, G.; Vernin, P.; Virieux, J.; Vladimirsky, E.; de Vries, G.; de Witt Huberts, P.; de Wolf, E.; Zaborov, D.; Zaccone, H.; Zakharov, V.; Zavatarelli, S.; de Zornoza, J. D.; Zúñiga, J.

    2005-02-01

    The ANTARES neutrino telescope is a large photomultiplier array designed to detect neutrino-induced upward-going muons by their Cherenkov radiation. Understanding the absorption and scattering of light in the deep Mediterranean is fundamental to optimising the design and performance of the detector. This paper presents measurements of blue and UV light transmission at the ANTARES site taken between 1997 and 2000. The derived values for the scattering length and the angular distribution of particulate scattering were found to be highly correlated, and results are therefore presented in terms of an absorption length λabs and an effective scattering length λscteff. The values for blue (UV) light are found to be λabs ≃ 60(26) m, λscteff≃265(122)m, with significant (˜15%) time variability. Finally, the results of ANTARES simulations showing the effect of these water properties on the anticipated performance of the detector are presented.

  14. Analytic Method on Characteristic Parameters of Bacteria in Water by Multiwavelength Transmission Spectroscopy

    Directory of Open Access Journals (Sweden)

    Yuxia Hu

    2017-01-01

    Full Text Available An analytic method together with the Mie scattering theory and Beer-Lambert law is proposed for the characteristic parameter determination of bacterial cells (Escherichia coli 10389 from multiwavelength transmission spectroscopy measurements. We calculate the structural parameters of E. coli cells, and compared with the microscopy, the relative error of cell volume is 7.90%, the cell number is compared with those obtained by plate counting, the relative error is l.02%, and the nucleic content and protein content of single E. coli cells are consistent with the data reported elsewhere. The proposed method can obtain characteristic parameters of bacteria as an excellent candidate for the rapid detection and identification of bacteria in the water.

  15. TECHNICAL FACT SHEET: A Systematic Evaluation of Dissolved Metals Loss during Water Sample Filtration

    Science.gov (United States)

    This research study examined how water quality collection and filtration approaches, including commonly used capsule and disc syringe filters, may cause losses in the amounts of soluble lead and copper found in a sample. A variety of commercially available filter materials with a...

  16. Respiratory water loss during rest and flight in European Starlings (Sturnus vulgaris)

    NARCIS (Netherlands)

    Engel, Sophia; Suthers, Roderick A.; Biebach, Herbert; Visser, G. Henk

    2006-01-01

    Respiratory water loss in Starlings (Sturnus vulgaris) at rest and during flight at ambient temperatures (T-amb) between 6 and 25 degrees C was calculated from respiratory airflow and exhaled air temperature. At rest, breathing frequency f(1.4 +/- 0.3 Hz) and tidal volume V-t (1.9 +/- 0.4 ml) were

  17. Adaptation of metabolism and evaporative water loss along an aridity gradient

    NARCIS (Netherlands)

    Tieleman, BI; Williams, JB; Bloomer, P

    2003-01-01

    Broad-scale comparisons of birds indicate the possibility of adaptive modification of basal metabolic rate (BMR) and total evaporative water loss (TEWL) in species from desert environments, but these might be confounded by phylogeny or phenotypic plasticity. This study relates variation in avian BMR

  18. Lipid composition of the stratum corneum and cutaneous water loss in birds along an aridity gradient

    NARCIS (Netherlands)

    Champagne, Alex M.; Munoz-Garcia, Agusti; Shtayyeh, Tamer; Tieleman, B. Irene; Hegemann, Arne; Clement, Michelle E.; Williams, Joseph B.

    2012-01-01

    Intercellular and covalently bound lipids within the stratum corneum (SC), the outermost layer of the epidermis, are the primary barrier to cutaneous water loss (CWL) in birds. We compared CWL and intercellular SC lipid composition in 20 species of birds from desert and mesic environments.

  19. Fruit cuticle lipid composition and water loss in a diverse collection of pepper (capsicum)

    Science.gov (United States)

    Pepper (Capsicum spp.) fruits are covered by a relatively thick coating of cuticle that limits fruit water loss, a trait previously associated with maintenance of post-harvest fruit quality during commercial marketing. We’ve examined the fruit cuticles from 50 diverse pepper genotypes from a world c...

  20. Water loss in horticultural products. Modelling, data analysis and theoretical considerations

    NARCIS (Netherlands)

    Tijskens, L.M.M.; Jacob, S.; Schouten, R.E.; Fernandez-Trujillo, J.P.; Dos-Santos, N.; Vangdal, E.; Pagan, E.; Perez Pastor, A.

    2010-01-01

    The water loss of individual fruit (melon, plum and mandarin) was analysed using the traditional diffusion based approach and a kinetic approach. Applying simple non linear regression, both approaches are the same, resulting in a quite acceptable analysis. However, by applying mixed effects non

  1. Quadratic head loss approximations for optimisation problems in water supply networks

    NARCIS (Netherlands)

    Pecci, Filippo; Abraham, E.; I, Stoianov

    2017-01-01

    This paper presents a novel analysis of the accuracy of quadratic approximations for the Hazen–Williams (HW) head loss formula, which enables the control of constraint violations in optimisation problems for water supply networks. The two smooth polynomial approximations considered here minimise the

  2. Thermal stratification in a hot water tank established by heat loss from the tank

    DEFF Research Database (Denmark)

    Fan, Jianhua; Furbo, Simon

    2009-01-01

    Results of experimental and numerical investigations of thermal stratification and natural convection in a vertical cylindrical hot water tank during standby periods are presented. The transient fluid flow and heat transfer in the tank during cooling caused by heat loss are investigated...... on the natural buoyancy resulting in downward flow along the tank side walls due to heat loss of the tank and the influence on thermal stratification of the tank by the downward flow and the corresponding upward flow in the central parts of the tank. Water temperatures at different levels of the tank...... by computational fluid dynamics (CFD) calculations and by thermal measurements. A tank with uniform temperatures and thermal stratification is studied. The distribution of the heat loss coefficient for the different parts of the tank is measured by tests and used as input to the CFD model. The investigations focus...

  3. Discontinuous gas exchange, water loss, and metabolism in Protaetia cretica (Cetoniinae, Scarabaeidae).

    Science.gov (United States)

    Matthews, Philip G D; White, Craig R

    2012-01-01

    Insects are at high risk of desiccation because of their small size, high surface-area-to-volume ratio, and air-filled tracheal system that ramifies throughout their bodies to transport O(2) and CO(2) to and from respiring cells. Although the tracheal system offers a high-conductance pathway for the movement of respiratory gases, it has the unintended consequence of allowing respiratory transpiration to the atmosphere. When resting, many species exchange respiratory gases discontinuously, and an early hypothesis for the origin of these discontinuous gas exchange cycles (DGCs) is that they serve to reduce respiratory water loss. In this study, we test this "hygric" hypothesis by comparing rates of CO(2) exchange and water loss among flower beetles Protaetia cretica (Cetoniinae, Scarabaeidae) breathing either continuously or discontinuously. We show that, consistent with the expectations of the hygric hypothesis, rates of total water loss are higher during continuous gas exchange than during discontinuous gas exchange and that the ratio of respiratory water loss to CO(2) exchange is lower during discontinuous gas exchange. This conclusion is in agreement with other studies of beetles and cockroaches that also support the hygric hypothesis. However, this result does not exclude other adaptive hypotheses supported by work on ants and moth pupae. This ambiguity may arise because there are multiple independent evolutionary origins of DGCs and no single adaptive function underlying their genesis. Alternatively, the observed reduction in water loss during DGCs may be a side effect of a nonadaptive gas exchange pattern that is elicited during periods of inactivity.

  4. Increase in transmission loss of single panels by addition of mass inclusions to a poro-elastic layer: Experimental investigation

    Science.gov (United States)

    Kidner, M. R. F.; Fuller, C. R.; Gardner, B.

    2006-06-01

    The insertion loss of standard acoustic blankets can be significantly improved at low frequencies by the addition of randomly placed mass inclusions to the poro-elastic layers. The improvement is much greater than that due to the mass effect alone. The mass inclusions act as resonant systems and so increase the structure impedance. This paper reports the results of experimental investigations into this phenomenon. Increases in insertion loss of 15 dB in the 100 Hz third octave band are reported.

  5. Hormonal control of integumentary water-loss: evidence for a novel neuroendocrine system in an insect (Periplaneta americana).

    Science.gov (United States)

    Treherne, J E; Willmer, P G

    1975-08-01

    An accelerated water-loss was observed in decapitated individuals, no equivalent increase being obtained following severance of the nervous connectives in the neck. Injection of brain and, to a lesser extent, corpus cardiacum extract resulted in a significant reduction in the rate of loss of water from decapitated individuals. The accelerated water-loss observed following decapitation appeared not to result from significant increase in excretory output or loss of water through the spiracles. It is suggested that integumentary transpiration may be affected by a blood-borne factor, or factors, which originate in the brain and corpus cardiacum.

  6. Monitoring of water supply connections as an element to reduce apparent losses of water?

    Science.gov (United States)

    Gwoździej-Mazur, Joanna

    2017-11-01

    Measuring instruments are designed to measure a given physical value, to process the obtained information and forward it to the observer. They are designed to perform specific tasks in specific working conditions and meeting the envisaged requirements. The most important requirement to be met by measuring instruments, is to preserve the established metrological characteristics. The basic and most common instrument for measuring the volume of flowing water is the water meter. Selecting the right water meter in the operating conditions is not an easy issue. The problem has been further intensified by decrease of water consumption which began in the 90s of the twentieth century and continuing to the present day. As a result, there has changed the structure of water consumption in both the residential and industrial applications. In this situation, a right selection of the optimal water meter it is an important case. The article presents the results of research in the field of characteristic flows in the water supply connections in multi-family housing using modern monitoring systems. It has been presented the calculated inequality ratio of water consumption, which can be helpful when designing a plumbing systems. In addition, the structure of water consumption due to the typical flow ranges was determined.

  7. Monitoring of water supply connections as an element to reduce apparent losses of water?

    Directory of Open Access Journals (Sweden)

    Gwoździej-Mazur Joanna

    2017-01-01

    Full Text Available Measuring instruments are designed to measure a given physical value, to process the obtained information and forward it to the observer. They are designed to perform specific tasks in specific working conditions and meeting the envisaged requirements. The most important requirement to be met by measuring instruments, is to preserve the established metrological characteristics. The basic and most common instrument for measuring the volume of flowing water is the water meter. Selecting the right water meter in the operating conditions is not an easy issue. The problem has been further intensified by decrease of water consumption which began in the 90s of the twentieth century and continuing to the present day. As a result, there has changed the structure of water consumption in both the residential and industrial applications. In this situation, a right selection of the optimal water meter it is an important case. The article presents the results of research in the field of characteristic flows in the water supply connections in multi-family housing using modern monitoring systems. It has been presented the calculated inequality ratio of water consumption, which can be helpful when designing a plumbing systems. In addition, the structure of water consumption due to the typical flow ranges was determined.

  8. Dew-point hygrometry system for measurement of evaporative water loss in infants.

    Science.gov (United States)

    Ariagno, R L; Glotzbach, S F; Baldwin, R B; Rector, D M; Bowley, S M; Moffat, R J

    1997-03-01

    Evaporation of water from the skin is an important mechanism in thermal homeostasis. Resistance hygrometry, in which the water vapor pressure gradient above the skin surface is calculated, has been the measurement method of choice in the majority of pediatric investigations. However, resistance hygrometry is influenced by changes in ambient conditions such as relative humidity, surface temperature, and convection currents. We have developed a ventilated capsule method that minimized these potential sources of measurement error and that allowed second-by-second, long-term, continuous measurements of evaporative water loss in sleeping infants. Air with a controlled reference humidity (dew-point temperature = 0 degree C) is delivered to a small, lightweight skin capsule and mixed with the vapor on the surface of the skin. The dew point of the resulting mixture is measured by using a chilled mirror dew-point hygrometer. The system indicates leaks, is mobile, and is accurate within 2%, as determined by gravimetric calibration. Examples from a recording of a 13-wk-old full-term infant obtained by using the system give evaporative water loss rates of approximately 0.02 mgH2O.cm-2.min-1 for normothermic baseline conditions and values up to 0.4 mgH2O.cm-2. min-1 when the subject was being warmed. The system is effective for clinical investigations that require dynamic measurements of water loss.

  9. Influence of ionic strength on the viscosities and water loss of bentonite suspensions containing polymers

    Directory of Open Access Journals (Sweden)

    Luciana Viana Amorim

    2007-03-01

    Full Text Available A study was made of the influence of ionic strength (S on the apparent (AV and plastic (PV viscosities and water loss (WL of sodium bentonite suspension with polymers. Na-bentonite was dispersed in water (4.86% w/w of different ionic strengths (S = 0.0, 0.015, 0.030 and 0.045 M followed by the addition of polymer. Three polymer samples were studied, i.e., low viscosity carboxymethyl cellulose (CMC BV, polyanionic cellulose (PAC, and partially hydrolyzed polyacrylamide (HPAM. The results indicated that the presence of salts and increased salinity greatly influence the apparent and plastic viscosities and water loss of bentonite suspensions with polymer.

  10. Gas exchange patterns and water loss rates in the Table Mountain cockroach, Aptera fusca (Blattodea: Blaberidae).

    Science.gov (United States)

    Groenewald, Berlizé; Bazelet, Corinna S; Potter, C Paige; Terblanche, John S

    2013-10-15

    The importance of metabolic rate and/or spiracle modulation for saving respiratory water is contentious. One major explanation for gas exchange pattern variation in terrestrial insects is to effect a respiratory water loss (RWL) saving. To test this, we measured the rates of CO2 and H2O release ( and , respectively) in a previously unstudied, mesic cockroach, Aptera fusca, and compared gas exchange and water loss parameters among the major gas exchange patterns (continuous, cyclic, discontinuous gas exchange) at a range of temperatures. Mean , and per unit did not differ among the gas exchange patterns at all temperatures (P>0.09). There was no significant association between temperature and gas exchange pattern type (P=0.63). Percentage of RWL (relative to total water loss) was typically low (9.79±1.84%) and did not differ significantly among gas exchange patterns at 15°C (P=0.26). The method of estimation had a large impact on the percentage of RWL, and of the three techniques investigated (traditional, regression and hyperoxic switch), the traditional method generally performed best. In many respects, A. fusca has typical gas exchange for what might be expected from other insects studied to date (e.g. , , RWL and cuticular water loss). However, we found for A. fusca that expressed as a function of metabolic rate was significantly higher than the expected consensus relationship for insects, suggesting it is under considerable pressure to save water. Despite this, we found no consistent evidence supporting the conclusion that transitions in pattern type yield reductions in RWL in this mesic cockroach.

  11. Improvement of transmission loss of a double panel by using active control with a virtual modal mass

    OpenAIRE

    Lhuillier , Vincent; Chesné , Simon; Gaudiller , Luc; Pezerat , Charles

    2013-01-01

    International audience; In this article, modal feedback control is proposed to reduce the sound transmission through finite double panels using lead zirconate titanate ceramic sensors and actuators bonded to the structure. Active control allows adding virtual modal damping and mass to the structure by the use of modal velocities and accelerations. In a first step, the equations describing the structure, the actuators, the acoustic excitation, and the acoustic radiation are detailed. Next, the...

  12. Solid Cattle Manure Less Prone to Phosphorus Loss in Tile Drainage Water.

    Science.gov (United States)

    Wang, Y T; Zhang, T Q; Tan, C S; Qi, Z M; Welacky, T

    2018-03-01

    Forms (e.g., liquid and solid) of manure influence the risk of P loss after land application. The objective of this study was to investigate the effects of P-based application of various forms of cattle manure (liquid, LCM; or solid, SCM) or inorganic P as triple superphosphate (IP) on soil P losses in tile drainage water. A 4-yr field experiment was conducted in a clay loam soil with a corn ( L.)-soybean [ (L.) Merr.] rotation in the Lake Erie basin. Over the 4 yr, the dissolved reactive P (DRP) flow-weighted mean concentration (FWMC) in tile drainage water was greater under SCM fertilization than under either IP or LCM fertilization. Despite its lower value on an annual basis, DRP FWMC rose dramatically immediately after LCM application. However, the differences in DRP FWMC did not result in detectable differences in DRP loads. Regarding particulate P and total P losses during the 4 yr, they were 68 and 47%, respectively, lower in the soils amended with SCM than in those with IP, whereas both values were similar between IP and LCM treatments. Overall, the P contained in solid cattle manure was less prone to P loss after land application. Accordingly, the present results can provide a basis for manure storage and application of best management practices designed to reduce P losses and improve crop growth. Copyright © by the American Society of Agronomy, Crop Science Society of America, and Soil Science Society of America, Inc.

  13. Soil loss by water erosion in areas under maize and jack beans intercropped and monocultures

    Directory of Open Access Journals (Sweden)

    Pedro Luiz Terra Lima

    2014-04-01

    Full Text Available Adequate soil management can create favorable conditions to reduce erosion and water runoff, consequently increase water soil recharge. Among management systems intercropping is highly used, especially for medium and small farmers. It is a system where two or more crops with different architectures and vegetative cycles are explored simultaneously at the same location. This research investigated the effects of maize intercropped with jack bean on soil losses due to water erosion, estimate C factor of Universal Soil Losses Equation (USLE and how it can be affected by soil coverage. The results obtained also contribute to database generation, important to model and estimate soil erosion. Total soil loss by erosion caused by natural rain, at Lavras, Minas Gerais, Brazil, were: 4.20, 1.86, 1.38 and 1.14 Mg ha-1, respectively, for bare soil, maize, jack bean and the intercropping of both species, during evaluated period. Values of C factor of USLE were: 0.039, 0.054 and 0.077 Mg ha Mg-1 ha-1 for maize, jack bean and intercropping between both crops, respectively. Maize presented lower vegetation cover index, followed by jack beans and consortium of the studied species. Intercropping between species showed greater potential on soil erosion control, since its cultivation resulted in lower soil losses than single crops cultivation, and this aspect is really important for small and medium farmers in the studied region.

  14. DESIGNING HYDRAULIC AIR CHAMBER IN WATER TRANSMISSION SYSTEMS USING GENETIC ALGORITHM

    Directory of Open Access Journals (Sweden)

    Abdorahim Jamal

    2016-09-01

    Full Text Available Transient flow control in Water Transmission Systems (WTS is one of the requirements of designing these systems. Hence, among control equipment, air chambers offer the best solution to control transient flow effects, i.e. both prevents water column separation and absorbs pressure increase. It is essential to carry out an accurate and optimized design of air chambers, not only due to high costs of their manufacturing but also their important protective role. Accordingly, hydraulic design parameters comprise tank volume, diameter of nozzle and coefficients of inflow and outflow of nozzle. In this paper, it is intended to optimize these parameters in order to minimize manufacturing costs. On the other hand, maximum and minimum pressures in main pipeline are considered as constraints which shall fall in allowed range. Therefore, a model has been developed which is a combination of a hydraulic simulation model of WTS and an optimization model based on genetic algorithm. This model is first applied to WTS of Dehgolan-Ghorveh plain as a case study. Results of this research demonstrate that based on suggested model, negative wave creation and pressure increase in pipeline is prevented as well as decrease in manufacturing costs of air chamber.

  15. Mycorrhizal fungi enhance plant nutrient acquisition and modulate nitrogen loss with variable water regimes.

    Science.gov (United States)

    Bowles, Timothy M; Jackson, Louise E; Cavagnaro, Timothy R

    2018-01-01

    Climate change will alter both the amount and pattern of precipitation and soil water availability, which will directly affect plant growth and nutrient acquisition, and potentially, ecosystem functions like nutrient cycling and losses as well. Given their role in facilitating plant nutrient acquisition and water stress resistance, arbuscular mycorrhizal (AM) fungi may modulate the effects of changing water availability on plants and ecosystem functions. The well-characterized mycorrhizal tomato (Solanum lycopersicum L.) genotype 76R (referred to as MYC+) and the mutant mycorrhiza-defective tomato genotype rmc were grown in microcosms in a glasshouse experiment manipulating both the pattern and amount of water supply in unsterilized field soil. Following 4 weeks of differing water regimes, we tested how AM fungi affected plant productivity and nutrient acquisition, short-term interception of a 15NH4+ pulse, and inorganic nitrogen (N) leaching from microcosms. AM fungi enhanced plant nutrient acquisition with both lower and more variable water availability, for instance increasing plant P uptake more with a pulsed water supply compared to a regular supply and increasing shoot N concentration more when lower water amounts were applied. Although uptake of the short-term 15NH4+ pulse was higher in rmc plants, possibly due to higher N demand, AM fungi subtly modulated NO3- leaching, decreasing losses by 54% at low and high water levels in the regular water regime, with small absolute amounts of NO3- leached (<1 kg N/ha). Since this study shows that AM fungi will likely be an important moderator of plant and ecosystem responses to adverse effects of more variable precipitation, management strategies that bolster AM fungal communities may in turn create systems that are more resilient to these changes. © 2017 John Wiley & Sons Ltd.

  16. Soil, water, and nutrient losses from management alternatives for degraded pasture in Brazilian Atlantic Rainforest biome.

    Science.gov (United States)

    Rocha Junior, Paulo Roberto da; Andrade, Felipe Vaz; Mendonça, Eduardo de Sá; Donagemma, Guilherme Kangussú; Fernandes, Raphael Bragança Alves; Bhattharai, Rabin; Kalita, Prasanta Kumar

    2017-04-01

    The objective of this study was to evaluate sediment, water and nutrient losses from different pasture managements in the Atlantic Rainforest biome. A field study was carried out in Alegre Espiríto Santo, Brazil, on a Xanthic Ferralsol cultivated with braquiaria (Brachiaria brizantha). The six pasture managements studied were: control (CON), chisel (CHI), fertilizer (FER), burned (BUR), plowing and harrowing (PH), and integrated crop-livestock (iCL). Runoff and sediment samples were collected and analyzed for calcium (Ca), magnesium (Mg), potassium (K), phosphorus (P) and organic carbon contents. Soil physical attributes and above and below biomass were also evaluated. The results indicated that higher water loss was observed for iCL (129.90mm) and CON (123.25mm) managements, and the sediment losses were higher for CON (10.24tha -1 ) and BUR (5.20tha -1 ) managements when compared to the other managements. Majority of the nutrients losses occurred in dissolved fraction (99% of Ca, 99% of Mg, 96% of K, and 65% of P), whereas a significant fraction of organic carbon (80%) loss occurred in a particulate form. Except for P, other nutrients (Ca, Mg and K) and organic carbon losses were higher in coarse sediment compared to fine sediment. The greater losses of sediment, organic carbon, and nutrients were observed for CON followed by BUR management (plosses from various practices, to reduce pasture degradation, farmers should adopt edaphic practices by applying lime and fertilize to improve pasture growth and soil cover, and reducing soil erosion in the hilly Brazilian Atlantic Rainforest biome. Copyright © 2016. Published by Elsevier B.V.

  17. Analysis of a small break loss-of-coolant accident of pressurized water reactor by APROS

    Energy Technology Data Exchange (ETDEWEB)

    Al-Falahi, A. [Helsinki Univ. of Technology, Espoo (Finland); Haennine, M. [VTT Energy, Espoo (Finland); Porkholm, K. [IVO International, Ltd., Vantaa (Finland)

    1995-09-01

    The purpose of this paper is to study the capability of APROS (Advanced PROcess Simulator) code to simulate the real plant thermal-hydraulic transient of a Small Break Loss-Of-Coolant Accident (SBLOCA) of Loss-Of-Fluid Test (LOFT) facility. The LOFT is a scaled model of a Pressurized Water Reactor (PWR). This work is a part of a larger validation of the APROS thermal-hydraulic models. The results of SBLOCA transient calculated by APROS showed a reasonable agreement with the measured data.

  18. Response of water deficit regime and soil amelioration on evapotranspiration loss and water use efficiency of maize ( Zea mays l.) in subtropical northeastern Himalayas

    Science.gov (United States)

    Marwein, M. A.; Choudhury, B. U.; Chakraborty, D.; Kumar, M.; Das, A.; Rajkhowa, D. J.

    2017-05-01

    Rainfed maize production in the hilly ecosystem of Northeastern Himalayas often suffers from moisture and soil acidity induced abiotic stresses. The present study measured evapotranspiration loss (ETc) of maize crop under controlled condition (pot experiment) of water deficit (W25-25 % and W50-50 % of field capacity soil moistures) and well watered (W100 = 100 % of field capacity (FC)) regimes in strong acid soils (pH = 4.3) of the Northeastern Himalayan Region of India. The response of soil ameliorants (lime) and phosphorus (P) nutrition under differential water regimes on ETc losses and water use efficiency was also studied. The measured seasonal ETc loss varied from 124.3 to 270.9 mm across treatment combinations. Imposition of water deficit stress resulted in significant ( p < 0.05) reduction (by 33-50 %) of seasonal ETc losses but was at the cost of delay in tasseling to silking, 47-65 % reduction in dry matter accumulation (DMA), 12-22 days shortening of grain formation period, and complete kernel abortion. Liming @ 4 t ha-1 significantly ( p < 0.05) increased ETc losses and DMA across water regimes but the magnitude of increase was higher in severely water deficit (W25) regime. Unlike lime, P nutrition improved DMA only in well-watered regimes (W100) while seasonal ETc loss was unaffected. Vegetative stage (tillering to tasseling) contributed the maximum ETc losses while weekly crop ETc loss was estimated highest during 11th-14th week after sowing (coincided with blistering stage) and then declined. Water use efficiency estimated from dry matter produced per unit ETc losses and irrigation water used varied from 4.33 to 9.43 g dry matter kg-1 water and 4.21 to 8.56 g dry matter kg-1, respectively. Among the input factors (water, P, and lime), water regime most strongly influenced the ETc loss, growth duration, grain formation, and water use efficiency of maize.

  19. Leakage Detection and Estimation Algorithm for Loss Reduction in Water Piping Networks

    Directory of Open Access Journals (Sweden)

    Kazeem B. Adedeji

    2017-10-01

    Full Text Available Water loss through leaking pipes constitutes a major challenge to the operational service of water utilities. In recent years, increasing concern about the financial loss and environmental pollution caused by leaking pipes has been driving the development of efficient algorithms for detecting leakage in water piping networks. Water distribution networks (WDNs are disperse in nature with numerous number of nodes and branches. Consequently, identifying the segment(s of the network and the exact leaking pipelines connected to this segment(s where higher background leakage outflow occurs is a challenging task. Background leakage concerns the outflow from small cracks or deteriorated joints. In addition, because they are diffuse flow, they are not characterised by quick pressure drop and are not detectable by measuring instruments. Consequently, they go unreported for a long period of time posing a threat to water loss volume. Most of the existing research focuses on the detection and localisation of burst type leakages which are characterised by a sudden pressure drop. In this work, an algorithm for detecting and estimating background leakage in water distribution networks is presented. The algorithm integrates a leakage model into a classical WDN hydraulic model for solving the network leakage flows. The applicability of the developed algorithm is demonstrated on two different water networks. The results of the tested networks are discussed and the solutions obtained show the benefits of the proposed algorithm. A noteworthy evidence is that the algorithm permits the detection of critical segments or pipes of the network experiencing higher leakage outflow and indicates the probable pipes of the network where pressure control can be performed. However, the possible position of pressure control elements along such critical pipes will be addressed in future work.

  20. Drainage water management combined with cover crop enhances reduction of soil phosphorus loss.

    Science.gov (United States)

    Zhang, T Q; Tan, C S; Zheng, Z M; Welacky, T; Wang, Y T

    2017-05-15

    Integrating multiple practices for mitigation of phosphorus (P) loss from soils may enhance the reduction efficiency, but this has not been studied as much as individual ones. A four-year study was conducted to determine the effects of cover crop (CC) (CC vs. no CC, NCC) and drainage water management (DWM) (controlled drainage with sub-irrigation, CDS, vs. regular free tile drainage, RFD) and their interaction on P loss through both surface runoff (SR) and tile drainage (TD) water in a clay loam soil of the Lake Erie region. Cover crop reduced SR flow volume by 32% relative to NCC, regardless of DWM treatment. In contrast, CC increased TD flow volume by 57 and 9.4% with CDS and RFD, respectively, compared to the corresponding DWM treatment with NCC. The total (SR+TD) field water discharge volumes were comparable amongst all the treatments. Cover crop reduced flow-weighted mean (FWM) concentrations of particulate P (PP) by 26% and total P (TP) by 12% in SR, while it didn't affect the FWM dissolved reactive P (DRP) concentration, regardless of DWM treatments. Compared with RFD, CDS reduced FWM DRP concentration in TD water by 19%, while CC reduced FWM PP and TP concentrations in TD by 21 and 17%, respectively. Total (SR+TD) soil TP loss was the least with CDS-CC followed by RFD-CC, CDS-NCC, and RFD-NCC. Compared with RFD-NCC, currently popular practice in the region, total TP loss was reduced by 23% with CDS-CC. The CDS-CC system can be an effective practice to ultimately mitigate soil P loading to water resource. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. Monitoring of water supply connections as an element to reduce apparent losses of water?

    OpenAIRE

    Gwoździej-Mazur Joanna

    2017-01-01

    Measuring instruments are designed to measure a given physical value, to process the obtained information and forward it to the observer. They are designed to perform specific tasks in specific working conditions and meeting the envisaged requirements. The most important requirement to be met by measuring instruments, is to preserve the established metrological characteristics. The basic and most common instrument for measuring the volume of flowing water is the water meter. Selecting the rig...

  2. RAPID WATER LOSS CAN EXTEND THE LIFETIME OF PLANETARY HABITABILITY

    Energy Technology Data Exchange (ETDEWEB)

    Kodama, Takanori; Abe, Yutaka [Department of Earth and Planetary Science, The University of Tokyo, Tokyo 113-0033 (Japan); Genda, Hidenori [Earth-Life Science Institute, Tokyo Institute of Technology, Tokyo 152-8550 (Japan); Zahnle, Kevin J., E-mail: koda@eps.s.u-tokyo.ac.jp [Space Science and Astrobiology Division, NASA Ames Research Center, California 94035 (United States)

    2015-10-20

    Two habitable planetary states are proposed: an aqua planet like the Earth and a land planet that has a small amount of water. Land planets keep liquid water under larger solar radiation compared to aqua planets. Water loss may change an aqua planet into a land planet, and the planet can remain habitable for a longer time than if it had remained an aqua planet. We calculate planetary evolution with hydrogen escape for different initial water inventories and different distances from the central star. We find that there are two conditions necessary to evolve an aqua planet into a land planet: the critical amount of water on the surface (M{sub ml}) consistent with a planet being a land planet, and the critical amount of water vapor in the atmosphere (M{sub cv}) that defines the onset of the runaway greenhouse state. We find that Earth-sized aqua planets with initial oceans <10% of the Earth's can evolve into land planets if M{sub cv} = 3 m in precipitable water and M{sub ml} = 5% of the Earth's ocean mass. Such planets can keep liquid water on their surface for another 2 Gyr. The initial amount of water and M{sub cv} are shown to be important dividing parameters of the planetary evolution path. Our results indicate that massive hydrogen escape could give a fresh start as another kind of habitable planet rather than the end of its habitability.

  3. RAPID WATER LOSS CAN EXTEND THE LIFETIME OF PLANETARY HABITABILITY

    International Nuclear Information System (INIS)

    Kodama, Takanori; Abe, Yutaka; Genda, Hidenori; Zahnle, Kevin J.

    2015-01-01

    Two habitable planetary states are proposed: an aqua planet like the Earth and a land planet that has a small amount of water. Land planets keep liquid water under larger solar radiation compared to aqua planets. Water loss may change an aqua planet into a land planet, and the planet can remain habitable for a longer time than if it had remained an aqua planet. We calculate planetary evolution with hydrogen escape for different initial water inventories and different distances from the central star. We find that there are two conditions necessary to evolve an aqua planet into a land planet: the critical amount of water on the surface (M ml ) consistent with a planet being a land planet, and the critical amount of water vapor in the atmosphere (M cv ) that defines the onset of the runaway greenhouse state. We find that Earth-sized aqua planets with initial oceans <10% of the Earth's can evolve into land planets if M cv = 3 m in precipitable water and M ml = 5% of the Earth's ocean mass. Such planets can keep liquid water on their surface for another 2 Gyr. The initial amount of water and M cv are shown to be important dividing parameters of the planetary evolution path. Our results indicate that massive hydrogen escape could give a fresh start as another kind of habitable planet rather than the end of its habitability

  4. SUNLIT AND SHADED MAIZE CANOPY WATER LOSS UNDER VARIED WATER STRESS

    Directory of Open Access Journals (Sweden)

    Antonio Odair Santos

    1999-12-01

    Full Text Available ABSTRACT The precise estimation of transpiration from plant canopies is important for the monitoring of crop water use and management of many agricultural operations related to water use planning. The aim of this study was to estimate transpiration from sunlit and shaded fractions of a maize ( Zea mays L. canopy, using the Penman-Monteith energy balance equation with modifications introduced by Fuchs et al. (1987 and Fuchs & Cohen (1989. Estimated values were validated by a heat pulse system, which was used to measure stem sap flow and by a weighing lysimeter. A relationship between incident radiation and leaf stomatal conductance for critical levels of leaf water potential was used to estimate transpiration. Results showed that computed transpiration of the shaded canopy ranged from 27 to 45% of the total transpiration when fluctuations in atmospheric demand and the level of water stress were taken in account. Hourly and daily estimates of transpiration showed agreement with lysimeter and heat pulse measurements on the well-watered plots. For the water-limited plots the precision of the estimate decreased due to difficulties in simulating the canopy stomatal conductance.

  5. Long-Term Ground-Water Levels and Transmissivity in the Blackstone River Basin, Northern Rhode Island

    Science.gov (United States)

    Eggleston, Jack R.; Church, Peter E.; Barbaro, Jeffrey R.

    2007-01-01

    Ground water provides about 7.7 million gallons per day, or 28 percent of total water use in the Rhode Island part of the Blackstone River Basin. Primary aquifers in the basin are stratified glacial deposits, composed mostly of sand and gravel along valley bottoms. The ground-water and surface-water system in the Blackstone River Basin is under stress due to population growth, out-of-basin water transfers, industrialization, and changing land-use patterns. Streamflow periodically drops below the Aquatic Base Flow standard, and ground-water withdrawals add to stress on aquatic habitat during low-flow periods. Existing hydrogeologic data were reviewed to examine historical water-level trends and to generate contour maps of water-table altitudes and transmissivity of the sand and gravel aquifer in the Blackstone River Basin in Rhode Island. On the basis of data from four long-term observation wells, water levels appear to have risen slightly in the study area during the past 55 years. Analysis of available data indicates that increased rainfall during the same period is a likely contributor to the water-level rise. Spatial patterns of transmissivity are shown over larger areas and have been refined on the basis of more detailed data coverage as compared to previous mapping studies.

  6. Antecedent conditions control carbon loss and downstream water quality from shallow, damaged peatlands.

    Science.gov (United States)

    Grand-Clement, E; Luscombe, D J; Anderson, K; Gatis, N; Benaud, P; Brazier, R E

    2014-09-15

    Losses of dissolved organic carbon (DOC) from drained peatlands are of concern, due to the effects this has on the delivery of ecosystem services, and especially on the long-term store of carbon and the provision of drinking water. Most studies have looked at the effect of drainage in deep peat; comparatively, little is known about the behaviour of shallow, climatically marginal peatlands. This study examines water quality (DOC, Abs(400), pH, E4/E6 and C/C) during rainfall events from such environments in the south west UK, in order to both quantify DOC losses, and understand their potential for restoration. Water samples were taken over a 19 month period from a range of drains within two different experimental catchments in Exmoor National Park; data were analysed on an event basis. DOC concentrations ranging between 4 and 21 mg L(-1) are substantially lower than measurements in deep peat, but remain problematic for the water treatment process. Dryness plays a critical role in controlling DOC concentrations and water quality, as observed through spatial and seasonal differences. Long-term changes in depth to water table (30 days before the event) are likely to impact on DOC production, whereas discharge becomes the main control over DOC transport at the time scale of the rainfall/runoff event. The role of temperature during events is attributed to an increase in the diffusion of DOC, and therefore its transport. Humification ratios (E4/E6) consistently below 5 indicate a predominance of complex humic acids, but increased decomposition during warmer summer months leads to a comparatively higher losses of fulvic acids. This work represents a significant contribution to the scientific understanding of the behaviour and functioning of shallow damaged peatlands in climatically marginal locations. The findings also provide a sound baseline knowledge to support research into the effects of landscape restoration in the future. Crown Copyright © 2014. Published by

  7. Soil, water and nutrient losses by interrill erosion from green cane cultivation

    Directory of Open Access Journals (Sweden)

    Gilka Rocha Vasconcelos da Silva

    2012-06-01

    Full Text Available Interrill erosion occurs by the particle breakdown caused by raindrop impact, by particle transport in surface runoff, by dragging and suspension of particles disaggregated from the soil surface, thus removing organic matter and nutrients that are essential for agricultural production. Crop residues on the soil surface modify the characteristics of the runoff generated by rainfall and the consequent particle breakdown and sediment transport resulting from erosion. The objective of this study was to determine the minimum amount of mulch that must be maintained on the soil surface of a sugarcane plantation to reduce the soil, water and nutrient losses by decreasing interrill erosion. The study was conducted in Pradópolis, São Paulo State, in 0.5 x 1.0 m plots of an Oxisol, testing five treatments in four replications. The application rates were based on the crop residue production of the area of 1.4 kg m-2 (T1- no cane trash; T2-25 % of the cane trash; T3- 50 % trash; T4-75 % trash; T5-100 % sugarcane residues on the surface, and simulated rainfall was applied at an intensity of 65 mm h-1 for 60 min. Runoff samples were collected in plastic containers and soon after taken to the laboratory to quantify the losses of soil, water and nutrients. To minimize soil loss by interrill erosion, 75 % of the cane mulch must be maintained on the soil, to control water loss 50 % must be maintained and 25 % trash controls organic matter and nutrient losses. This information can contribute to optimize the use of this resource for soil conservation on the one hand and the production of clean energy in sugar and alcohol industries on the other.

  8. Electron-induced hydrogen loss in uracil in a water cluster environment

    International Nuclear Information System (INIS)

    Smyth, M.; Kohanoff, J.; Fabrikant, I. I.

    2014-01-01

    Low-energy electron-impact hydrogen loss due to dissociative electron attachment (DEA) to the uracil and thymine molecules in a water cluster environment is investigated theoretically. Only the A ′ -resonance contribution, describing the near-threshold behavior of DEA, is incorporated. Calculations are based on the nonlocal complex potential theory and the multiple scattering theory, and are performed for a model target with basic properties of uracil and thymine, surrounded by five water molecules. The DEA cross section is strongly enhanced when the attaching molecule is embedded in a water cluster. This growth is due to two effects: the increase of the resonance lifetime and the negative shift in the resonance position due to interaction of the intermediate negative ion with the surrounding water molecules. A similar effect was earlier found in DEA to chlorofluorocarbons

  9. Measurement of evaporative water loss in small animals by dew-point hygrometry.

    Science.gov (United States)

    Bernstein, M H; Hudson, D M; Stearns, J M; Hoyt, R W

    1977-08-01

    This paper presents the procedures and equations to be utilized for measurement of evaporative water loss (mw), by use of the dew-point hygrometer, in small animals exposed to air containing water vapor in an open-flow system. The system accounted accurately for the water evaporated from a bubble flask. In addition, hygrometric measurements of pulmocutaneous mw in pigeons (Columba livia, mean mass 0.31 kg) agreed closely with simultaneous gravimetric measurements, utilizing a desiccant in the sample stream, in a manner independently of air temperature (Ta, 20 or 40 degrees C), ambient water vapor pressure (PW, 4-16 10(2) Pa), or mw (5-66 mg-min-1). Evaporation in pigeons was independent of PW at 20 degrees C, but increased with decreasing PW at 40 degrees C, suggesting differences in ventilatory adjustments to changes in PW at the two temperatures.

  10. Electron-induced hydrogen loss in uracil in a water cluster environment

    Energy Technology Data Exchange (ETDEWEB)

    Smyth, M.; Kohanoff, J. [Atomistic Simulation Centre, Queen' s University Belfast, Belfast BT7 1NN, Northern Ireland (United Kingdom); Fabrikant, I. I., E-mail: ifabrikant1@unl.edu [Department of Physics and Astronomy, University of Nebraska, Lincoln, Nebraska 68588, USA and Department of Physical Sciences, The Open University, Walton Hall, Milton Keynes MK7 6AA (United Kingdom)

    2014-05-14

    Low-energy electron-impact hydrogen loss due to dissociative electron attachment (DEA) to the uracil and thymine molecules in a water cluster environment is investigated theoretically. Only the A{sup ′}-resonance contribution, describing the near-threshold behavior of DEA, is incorporated. Calculations are based on the nonlocal complex potential theory and the multiple scattering theory, and are performed for a model target with basic properties of uracil and thymine, surrounded by five water molecules. The DEA cross section is strongly enhanced when the attaching molecule is embedded in a water cluster. This growth is due to two effects: the increase of the resonance lifetime and the negative shift in the resonance position due to interaction of the intermediate negative ion with the surrounding water molecules. A similar effect was earlier found in DEA to chlorofluorocarbons.

  11. STRATOSPHERIC TEMPERATURES AND WATER LOSS FROM MOIST GREENHOUSE ATMOSPHERES OF EARTH-LIKE PLANETS

    Energy Technology Data Exchange (ETDEWEB)

    Kasting, James F.; Kopparapu, Ravi K. [Department of Geosciences, The Pennsylvania State University, State College, PA 16801 (United States); Chen, Howard, E-mail: jfk4@psu.edu, E-mail: hwchen@bu.edu [Department of Astronomy, Boston University, 725 Commonwealth Ave., Boston, MA 02215 (United States)

    2015-11-01

    A radiative-convective climate model is used to calculate stratospheric temperatures and water vapor concentrations for ozone-free atmospheres warmer than that of modern Earth. Cold, dry stratospheres are predicted at low surface temperatures, in agreement with recent 3D calculations. However, at surface temperatures above 350 K, the stratosphere warms and water vapor becomes a major upper atmospheric constituent, allowing water to be lost by photodissociation and hydrogen escape. Hence, a moist greenhouse explanation for loss of water from Venus, or some exoplanet receiving a comparable amount of stellar radiation, remains a viable hypothesis. Temperatures in the upper parts of such atmospheres are well below those estimated for a gray atmosphere, and this factor should be taken into account when performing inverse climate calculations to determine habitable zone boundaries using 1D models.

  12. STRATOSPHERIC TEMPERATURES AND WATER LOSS FROM MOIST GREENHOUSE ATMOSPHERES OF EARTH-LIKE PLANETS

    International Nuclear Information System (INIS)

    Kasting, James F.; Kopparapu, Ravi K.; Chen, Howard

    2015-01-01

    A radiative-convective climate model is used to calculate stratospheric temperatures and water vapor concentrations for ozone-free atmospheres warmer than that of modern Earth. Cold, dry stratospheres are predicted at low surface temperatures, in agreement with recent 3D calculations. However, at surface temperatures above 350 K, the stratosphere warms and water vapor becomes a major upper atmospheric constituent, allowing water to be lost by photodissociation and hydrogen escape. Hence, a moist greenhouse explanation for loss of water from Venus, or some exoplanet receiving a comparable amount of stellar radiation, remains a viable hypothesis. Temperatures in the upper parts of such atmospheres are well below those estimated for a gray atmosphere, and this factor should be taken into account when performing inverse climate calculations to determine habitable zone boundaries using 1D models

  13. The assessment of water loss from a damaged distribution pipe using the FEFLOW software

    Directory of Open Access Journals (Sweden)

    Iwanek Małgorzata

    2017-01-01

    Full Text Available Common reasons of real water loss in distribution systems are leakages caused by the failures or pipe breakages. Depending on the intensity of leakage from a damaged buried pipe, water can flow to the soil surface just after the failure occurs, much later or never at all. The localization of the place where the pipe breakage occurs is relatively easy when water outflow occurs on the soil surface. The volume of lost water strongly depends on the time it takes to localize the place of a pipe breakage. The aim of this paper was to predict the volume of water lost between the moment of a failure occurring and the moment of water outflow on the soil surface, during a prospective failure in a distribution system. The basis of the analysis was a numerical simulation of a water pipe failure using the FEFLOW v. 5.3 software (Finite Element subsurface FLOW systems for a real middle-sized distribution system. Simulations were conducted for variants depending on pipes’ diameter (80÷200 mm for minimal and maximal hydraulic pressure head in the system (20.14 and 60.41 m H2O, respectively. FEFLOW software application enabled to select places in the water system where possible failures would be difficult to detect.

  14. Apparent losses due to domestic water meter under-registration in South Africa

    OpenAIRE

    Couvelis, FA; van Zyl, JE

    2015-01-01

    This study investigated the extent of apparent losses due to water meter under-registration in South Africa. This was done by first estimating the under-registration of new meters due to on-site leakage, and then the additional under-registration due to meter aging. The extent and flow distributions of on-site leakage were determined through field studies in Cape Town, Mangaung and Johannesburg, by measuring the flow through new water meters when no legitimate consumption occurred on the prop...

  15. Respiratory evaporative water loss during hovering and forward flight in hummingbirds.

    Science.gov (United States)

    Powers, Donald R; Getsinger, Philip W; Tobalske, Bret W; Wethington, Susan M; Powers, Sean D; Warrick, Douglas R

    2012-02-01

    Hummingbirds represent an end point for small body size and water flux in vertebrates. We explored the role evaporative water loss (EWL) plays in management of their large water pool and its use in dissipating metabolic heat. We measured respiratory evaporative water loss (REWL) in hovering hummingbirds in the field (6 species) and over a range of speeds in a wind tunnel (1 species) using an open-circuit mask respirometry system. Hovering REWL during the active period was positively correlated with operative temperature (T(e)) likely due to some combination of an increase in the vapor-pressure deficit, increase in lung ventilation rate, and reduced importance of dry heat transfer at higher T(e). In rufous hummingbirds (Selasphorus rufus; 3.3g) REWL during forward flight at 6 and 10 m/s was less than half the value for hovering. The proportion of total dissipated heat (TDH) accounted for by REWL during hovering at T(e)> 40°C was hummingbirds is a relatively small component of the water budget compared with other bird species (hummingbirds. Copyright © 2011 Elsevier Inc. All rights reserved.

  16. The Effect of Different Water Temperatures on Retention Loss and Material Degradation of Locator Attachments.

    Science.gov (United States)

    Chiu, Lillian Pui Yuk; Vitale, Nicola Di; Petridis, Haralampos; McDonald, Ailbhe

    2017-08-01

    To examine the changes in Locator attachments after exposure to different water temperatures and cyclic loading. Four groups of pink Locator attachments (3.0 lb. light retention replacement patrix attachments; 10 per group) were soaked for the equivalent of 5 years of use in distilled water at the following temperatures: 20°C, 37°C, 60°C. One group was kept dry to test the effect of water. A universal testing machine was used to measure the retention force of each treated attachment during 5500 insertion and removal cycles, simulating approximately 5 years of use. The results were compared using Kruskal-Wallis one-way ANOVA by ranks. Surface changes of tested attachments were examined using scanning electron microscopy (SEM). The exposure to 60°C water significantly increased the percentage of retention loss in Locator attachments (p < 0.05) compared to the 20°C water group and significantly reduced the final retention force compared to the other groups (p < 0.05). SEM examinations revealed severe cracking and material degradation in Locator attachments after exposure to 60°C water and cyclic loading, which were not evident in other groups. Cracking was observed after exposure to 60˚C water before cyclic loading. Exposure to 60°C water, potentially similar to denture cleansing procedures, could cause cracking in Locator attachments. Cracking is associated with hydrolytic degradation of nylon at 60°C. The change in structure could result in a significant loss of retention. © 2016 by the American College of Prosthodontists.

  17. Transepidermal water loss in cats: comparison of three differently clipped sites to assess the influence of hair coat on transepidermal water loss values.

    Science.gov (United States)

    Momota, Yutaka; Shimada, Kenichiroh; Takami, Akina; Akaogi, Harumi; Takasaki, Mariko; Mimura, Kana; Azakami, Daigo; Ishioka, Katsumi; Nakamura, Yuka; Sako, Toshinori

    2013-08-01

    The measurement of transepidermal water loss (TEWL) is one of the parameters that can be used to assess skin barrier function. The variability and reliability of TEWL measurements in dogs have been controversial, and the hair coat has been considered as one of the factors that may cause variation of TEWL values. The aims of the study were to establish a suitable procedure for measuring feline TEWL, to evaluate the influence of hair coat on TEWL measurements and to assess variations of TEWL at different anatomical sites. Transepidermal water loss was measured using a closed-chamber evaporimeter, the VapoMeter(®). We compared three adjacent sites in the groin area of 10 clinically normal, domestic short hair cats. One site was unclipped, the second was trimmed with scissors and the third was shaved using electric clippers. Values of TEWL were obtained for 48 h after trimming with scissors and clippers. Five sites were clipped (upper back, lumbar back, lateral thigh, axillae and groin), and the TEWL was measured. The mean and SD of TEWL values of the clipper-trimmed site were the smallest, followed in order by the site trimmed with scissors and the unclipped site. The TEWL values were statistically constant in the clipper-trimmed site, while the values in the unclipped sites were not. There was no statistically significant difference in TEWL values between all of the anatomical sites except for the axillae. Hair clipping of sites with electric clippers is recommended for TEWL measurement in cats. © 2013 ESVD and ACVD.

  18. Loss-of-Fluid Test findings in pressurized water reactor core's thermal-hydraulic behavior

    International Nuclear Information System (INIS)

    Russell, M.

    1983-01-01

    This paper summarizes the pressurized water reactor (PWR) core's thermal-hydraulic behavior findings from experiments performed at the Loss-of-Fluid Test (LOFT) Facility at the Idaho National Engineering Laboratory. The potential impact of these findings on the safety and economics of PWR's generation of electricity is also discussed. Reviews of eight important findings in the core's physical behavior and in experimental methods are presented with supporting evidence

  19. The effects of uncoated paper on skin moisture and transepidermal water loss in bedridden patients.

    Science.gov (United States)

    Shin, Yong Soon; Kim, Hyun Jung; Moon, Nam-Kyung; Ahn, Young Hee; Kim, Kyoung-Ok

    2012-09-01

    The aims of this study were to measure skin moisture and transepidermal water loss after application of uncoated paper and to compare skin moisture and transepidermal water loss after use of uncoated paper and disposable underpads. The study was a cross-over, prospective, open-labeled, randomized trial. Bedridden patients aged≥18 years at a medical center in Korea were included. Treatment order was randomly assigned using block randomization, with a block size of 4 and an assignment rate of one-by-one. Skin moisture was measured using a Corneometer 825 and transepidermal water loss was measured using a Tewameter 300. Skin moisture after application of an uncoated paper was significantly lower than observed after application of a disposable underpad (mean 40.6 and SD 13.1 vs. mean 64.6 and SD 23.7, p<0.001). Transepidermal water loss also showed greater health scores after using uncoated paper (mean 11.1 and SD 5.7 g/m2/hour) than after applying a disposable underpad (mean 23.2 and SD 11.1 g/m2 /hour, p<0.001). There were no statistical between-group differences in room temperature, relative humidity, and body temperature. We found that uncoated paper was helpful in avoiding excessive moisture without adverse effects. As indicated by the results of this study, uncoated paper can be applied to bed-ridden patients who required incontinence care. Nurses may consider using uncoated paper as one of nursing methods in the routine care of bed-ridden patients for moisture control. © 2012 Blackwell Publishing Ltd.

  20. PSB-VVER simulation of Kozloduy NPP 'loss of feed water transient'

    Energy Technology Data Exchange (ETDEWEB)

    Groudev, P.P. [Institute for Nuclear Research and Nuclear Energy, Tzarigradsko Shaussee 72, Sofia 1784 (Bulgaria)]. E-mail: pavlinpg@inrne.bas.bg; Stefanova, A.E. [Institute for Nuclear Research and Nuclear Energy, Tzarigradsko Shaussee 72, Sofia 1784 (Bulgaria)]. E-mail: antoanet@inrne.bas.bg; Gencheva, R.V. [Institute for Nuclear Research and Nuclear Energy, Tzarigradsko Shaussee 72, Sofia 1784 (Bulgaria)]. E-mail: roseh@inrne.bas.bg; Pavlova, M.P. [Institute for Nuclear Research and Nuclear Energy, Tzarigradsko Shaussee 72, Sofia 1784 (Bulgaria)]. E-mail: pavlova@inrne.bas.bg

    2005-04-01

    This paper provides a comparison between the PSB test facility experimental results obtained during the simulation of loss of feed water transient (LOFW) and the calculation results received by INRNE computer model of the same test facility. Integral thermal-hydraulic PSB-VVER test facility located at Electrogorsk Research and Engineering Center on NPPs Safety (EREC) was put in operation in 1998. The structure of the test facility allows experimental studies under steady state, transient and accident conditions. RELAP5/MOD3.2 computer code has been used to simulate the loss of feed water transient in a PSB-VVER model. This model was developed at the Institute for Nuclear Research and Nuclear Energy for simulation of loss of feed water transient. The objective of the experiment 'loss of feed water', which has been performed at PSB-VVER test facility is simulation of Kozloduy NPP LOFW transient. One of the main requirements to the experiment scenario has been to reproduce all main events and phenomena that occurred in Kozloduy NPP during the LOFW transient. Analyzing the PSB-VVER test with a RELAP5/MOD3.2 computer code as a standard problem allows investigating the phenomena included in the VVER code validation matrix as 'integral system effects' and 'natural circulation'. For assessment of the RELAP5 capability to predict the 'Integral system effect' phenomenon the following RELAP5 quantities are compared with external trends: the primary pressure and the hot and cold leg temperatures. In order to assess the RELAP5 capability to predict the 'Natural circulation' phenomenon the hot and cold leg temperatures behavior have been investigated. This report was possible through the participation of leading specialists from Kozloduy NPP and with the support of Argonne National Laboratory (ANL), under the International Nuclear Safety Program (INSP) of the United States Department of Energy.

  1. Study of semiconductor valence plasmon line shapes via electron energy-loss spectroscopy in the transmission electron microscope

    International Nuclear Information System (INIS)

    Kundmann, M.K.

    1988-11-01

    Electron energy-loss spectra of the semiconductors Si, AlAs, GaAs, InAs, InP, and Ge are examined in detail in the regime of outer-shell and plasmon energy losses (0--100eV). Particular emphasis is placed on modeling and analyzing the shapes of the bulk valence plasmon lines. A line shape model based on early work by Froehlich is derived and compared to single-scattering probability distributions extracted from the measured spectra. Model and data are found to be in excellent agreement, thus pointing the way to systematic characterization of the plasmon component of EELS spectra. The model is applied to three separate investigations. 82 refs

  2. Evaluation for Loss of Lubrication Performance of Black Oxide, Superfinished, and As-Ground Surfaces for Use in Rotorcraft Transmissions

    Science.gov (United States)

    2016-09-01

    9. SPONSORING/ MONITORING AGENCY NAME(S) AND ADDRESS(ES) 10. SPONSOR/MONITOR’S ACRONYM(S) 11. SPONSOR/MONITOR’S REPORT NUMBER(S) 12...loss of lubrication. The ball-on-disc tribometer monitors the coefficient of friction within the contact, and scuffing initiation is indicated by a...corresponding set of as-ground balls. The ISF specimens had an Sa roughness value averaging to be 55 nm. A competitor process for improved surface

  3. Epicuticular waxes from caatinga and cerrado species and their efficiency against water loss

    Directory of Open Access Journals (Sweden)

    Oliveira Antonio F. M.

    2003-01-01

    Full Text Available The effects of the contents and chemical composition of the foliar epicuticular waxes of species from the caatinga (Aspidosperma pyrifolium, Capparis yco, Maytenus rigida and Ziziphus joazeiro and cerrado (Aristolochia esperanzae, Didymopanax vinosum, Strychnos pseudoquina and Tocoyena formosa were evaluated as to the resistance to water loss by means of an experimental device constructed for this purpose. In general, the waxes of the caatinga species investigated were more efficient against water loss than cerrado species. Increase of the thickness of the waxy deposits from 40 to 90m g.cm-2 had no significant effect on the resistance to water loss. The chemistry of the wax constituents was shown to be an important factor to determine the degree of resistance to evaporation. n-Alkanes and alcoholic triterpenes were the most efficient barriers, while hentriacontan-16-one (a ketone and ursolic acid (an acid triterpene revealed lowefficiency. The higher efficiency of the waxes of the leaves from caatinga species (mainly those of C. yco and Z. joazeiro is probably accounted for the predominance of n-alkanes in their composition. The lower efficiency of the waxes of A. pyrifolium (caatinga, T. formosa and A. esperanzae (both species from the cerrado is probably a consequence of the predominance of triterpenoids in the waxes of the two former species and hentriacontan-16-one in the latter.

  4. Maintenance of water uptake and reduced water loss contribute to water stress tolerance of Spiraea alba Du Roi and Spiraea tomentosa L.

    Science.gov (United States)

    Stanton, Kelly M; Mickelbart, Michael V

    2014-01-01

    Two primarily eastern US native shrubs, Spiraea alba Du Roi and Spiraea tomentosa L., are typically found growing in wet areas, often with standing water. Both species have potential for use in the landscape, but little is known of their environmental requirements, including their adaptation to water stress. Two geographic accessions of each species were evaluated for their response to water stress under greenhouse conditions. Above-ground biomass, water relations and gas exchange were measured in well-watered and water stress treatments. In both species, water stress resulted in reduced growth, transpiration and pre-dawn water potential. However, both species also exhibited the ability to osmotically adjust to lower soil water content, resulting in maintained midday leaf turgor potential in all accessions. Net CO2 assimilation was reduced only in one accession of S. alba, primarily due to large reductions in stomatal conductance. S. tomentosa lost a larger proportion of leaves than S. alba in response to water stress. The primary water stress tolerance strategies of S. alba and S. tomentosa appear to be the maintenance of water uptake and reduced water loss.

  5. An environmental sample chamber for reliable scanning transmission x-ray microscopy measurements under water vapor

    Energy Technology Data Exchange (ETDEWEB)

    Kelly, Stephen T.; Nigge, Pascal; Prakash, Shruti; Gilles, Mary K. [Chemical Sciences Division, Lawrence Berkeley National Laboratory, Berkeley, California 94720 (United States); Laskin, Alexander; Wang, Bingbing [William R. Wiley Environmental Molecular Sciences Laboratory, Pacific Northwest National Laboratory, Richland, Washington 99352 (United States); Tyliszczak, Tolek [Advanced Light Source, Lawrence Berkeley National Laboratory, Berkeley, California 94720 (United States); Leone, Stephen R. [Chemical Sciences Division, Lawrence Berkeley National Laboratory, Berkeley, California 94720 (United States); Department of Chemistry and Department of Physics, University of California, Berkeley, California 94720 (United States)

    2013-07-15

    We have designed, fabricated, and tested a compact gas-phase reactor for performing in situ soft x-ray scanning transmission x-ray microscopy (STXM) measurements. The reactor mounts directly to the existing sample holder used in the majority of STXM instruments around the world and installs with minimal instrument reconfiguration. The reactor accommodates many gas atmospheres, but was designed specifically to address the needs of measurements under water vapor. An on-board sensor measures the relative humidity and temperature inside the reactor, minimizing uncertainties associated with measuring these quantities outside the instrument. The reactor reduces x-ray absorption from the process gas by over 85% compared to analogous experiments with the entire STXM instrument filled with process gas. Reduced absorption by the process gas allows data collection at full instrumental resolution, minimizes radiation dose to the sample, and results in much more stable imaging conditions. The reactor is in use at the STXM instruments at beamlines 11.0.2 and 5.3.2.2 at the Advanced Light Source.

  6. Assessment of electrical stunning in fresh water of African Catfish (Clarias gariepinus) and chilling in ice water for loss of consciousness and sensibility

    NARCIS (Netherlands)

    Lambooij, E.; Kloosterboer, R.J.; Gerritzen, M.A.; Vis, van de J.W.

    2006-01-01

    The overall objective of the study was to evaluate loss of consciousness and sensibility after electrical stunning in fresh water and live chilling in ice water for slaughter of African catfish using measurement of electrical brain and heart activity. To provoke immediate loss of consciousness and

  7. Interfacial phonon scattering and transmission loss in >1 μm thick silicon-on-insulator thin films

    Science.gov (United States)

    Jiang, Puqing; Lindsay, Lucas; Huang, Xi; Koh, Yee Kan

    2018-05-01

    Scattering of phonons at boundaries of a crystal (grains, surfaces, or solid/solid interfaces) is characterized by the phonon wavelength, the angle of incidence, and the interface roughness, as historically evaluated using a specularity parameter p formulated by Ziman [Electrons and Phonons (Clarendon Press, Oxford, 1960)]. This parameter was initially defined to determine the probability of a phonon specularly reflecting or diffusely scattering from the rough surface of a material. The validity of Ziman's theory as extended to solid/solid interfaces has not been previously validated. To better understand the interfacial scattering of phonons and to test the validity of Ziman's theory, we precisely measured the in-plane thermal conductivity of a series of Si films in silicon-on-insulator (SOI) wafers by time-domain thermoreflectance (TDTR) for a Si film thickness range of 1-10 μm and a temperature range of 100-300 K. The Si /SiO2 interface roughness was determined to be 0.11 ±0.04 nm using transmission electron microscopy (TEM). Furthermore, we compared our in-plane thermal conductivity measurements to theoretical calculations that combine first-principles phonon transport with Ziman's theory. Calculations using Ziman's specularity parameter significantly overestimate values from the TDTR measurements. We attribute this discrepancy to phonon transmission through the solid/solid interface into the substrate, which is not accounted for by Ziman's theory for surfaces. The phonons that are specularly transmitted into an amorphous layer will be sufficiently randomized by the time they come back to the crystalline Si layer, the effect of which is practically equivalent to a diffuse reflection at the interface. We derive a simple expression for the specularity parameter at solid/amorphous interfaces and achieve good agreement between calculations and measurement values.

  8. Effect of in-material losses on terahertz absorption, transmission, and reflection in photonic crystals made of polar dielectrics

    Energy Technology Data Exchange (ETDEWEB)

    Serebryannikov, Andriy E., E-mail: andser@amu.edu.pl [Faculty of Physics, Adam Mickiewicz University, 61-614 Poznań (Poland); Nanotechnology Research Center—NANOTAM, Bilkent University, 06800 Ankara (Turkey); Nojima, S. [Yokohama City University, Department of Nanosystem Science, Graduate School of Nanobioscience, Kanazawa Ku, 22-2 Seto, Yokohama, Kanagawa 2360027 (Japan); Alici, K. B. [TUBITAK Marmara Research Center, Materials Institute, 41470 Gebze, Kocaeli (Turkey); Ozbay, Ekmel [Nanotechnology Research Center—NANOTAM, Bilkent University, 06800 Ankara (Turkey)

    2015-10-07

    The effect of the material absorption factor on terahertz absorption (A), transmittance (T), and reflectance (R) for slabs of PhC that comprise rods made of GaAs, a polar dielectric, is studied. The main goal was to illustrate how critical a choice of the absorption factor for simulations is and to indicate the importance of the possible modification of the absorption ability by using either active or lossy impurities. The spectra of A, T, and R are strongly sensitive to the location of the polaritonic gap with respect to the photonic pass and stop bands connected with periodicity that enables the efficient combination of the effects of material and structural parameters. It will be shown that the spectra can strongly depend on the utilized value of the material absorption factor. In particular, both narrow and wide absorption bands may appear owing to a variation of the material parameters with a frequency in the vicinity of the polaritonic gap. The latter are often achieved at wideband suppression of transmission, so that an ultra-wide stop band can appear as a result of adjustment of the stop bands having different origin. The results obtained at simultaneous variation of the absorption factor and frequency, and angle of incidence and frequency, indicate the possibility of the existence of wide ranges of tolerance, in which the basic features do remain. This allows for mitigating the accuracy requirements for the absorption factor in simulations and promises the efficient absorption of nonmonochromatic waves and beams with a wide angular spectrum. Suppression of narrowband effects in transmission is demonstrated at rather large values of the absorption factor, when they appear due to either the defect modes related to structural defects or dispersion inspired variations of the material parameters in the vicinity of the polaritonic gap. Comparison with auxiliary structures helps one to detect the common features and differences of homogeneous slabs and slabs of a

  9. Nutrient and Organic Carbon Losses, Enrichment Rate, and Cost of Water Erosion

    Directory of Open Access Journals (Sweden)

    Ildegardis Bertol

    Full Text Available ABSTRACT Soil erosion from water causes loss of nutrients and organic carbon, enriches the environment outside the erosion site, and results in costs. The no-tillage system generates increased nutrient and C content in the topsoil and, although it controls erosion, it can produce a more enriched runoff than in the conventional tillage system. This study was conducted in a Humic Cambisol in natural rainfall from 1997 to 2012 to quantify the contents and total losses of nutrients and organic C in soil runoff, and to calculate the enrichment rates and the cost of these losses. The treatments evaluated were: a soil with a crop, consisting of conventional tillage with one plowing + two harrowings (CT, minimum tillage with one chisel plowing + one harrowing (MT, and no tillage (NT; and b bare soil: one plowing + two harrowings (BS. In CT, MT, and NT, black oat, soybean, vetch, corn, turnip, and black beans were cultivated. Over the 15 years, 15.5 Mg ha-1 of limestone, 525 kg ha-1 of N (urea, 1,302 kg ha-1 of P2O5 (triple superphosphate, and 1,075 kg ha-1 of K2O (potassium chloride were used in the soil. The P, K, Ca, Mg, and organic C contents in the soil were determined and also the P, K, Ca, and Mg sediments in the runoff water. From these contents, the total losses, the enrichment rates (ER, and financial losses were calculated. The NT increased the P, K, and organic C contents in the topsoil. The nutrients and organic C content in the runoff from NT was greater than from CT, showing that NT was not a fully conservationist practice for soil. The linear model y = a + bx fit the data within the level of significance (p≤0.01 when the values of P, K, and organic C in the sediments from erosion were related to those values in the soil surface layer. The nutrient and organic C contents were higher in the sediments from erosion than in the soil where the erosion originated, generating values of ER>1 for P, K, and organic C. The value of the total losses

  10. Optimal Siting and Sizing of Multiple DG Units for the Enhancement of Voltage Profile and Loss Minimization in Transmission Systems Using Nature Inspired Algorithms

    Directory of Open Access Journals (Sweden)

    Ambika Ramamoorthy

    2016-01-01

    Full Text Available Power grid becomes smarter nowadays along with technological development. The benefits of smart grid can be enhanced through the integration of renewable energy sources. In this paper, several studies have been made to reconfigure a conventional network into a smart grid. Amongst all the renewable sources, solar power takes the prominent position due to its availability in abundance. Proposed methodology presented in this paper is aimed at minimizing network power losses and at improving the voltage stability within the frame work of system operation and security constraints in a transmission system. Locations and capacities of DGs have a significant impact on the system losses in a transmission system. In this paper, combined nature inspired algorithms are presented for optimal location and sizing of DGs. This paper proposes a two-step optimization technique in order to integrate DG. In a first step, the best size of DG is determined through PSO metaheuristics and the results obtained through PSO is tested for reverse power flow by negative load approach to find possible bus locations. Then, optimal location is found by Loss Sensitivity Factor (LSF and weak (WK bus methods and the results are compared. In a second step, optimal sizing of DGs is determined by PSO, GSA, and hybrid PSOGSA algorithms. Apart from optimal sizing and siting of DGs, different scenarios with number of DGs (3, 4, and 5 and PQ capacities of DGs (P alone, Q alone, and  P and Q both are also analyzed and the results are analyzed in this paper. A detailed performance analysis is carried out on IEEE 30-bus system to demonstrate the effectiveness of the proposed methodology.

  11. Optimal Siting and Sizing of Multiple DG Units for the Enhancement of Voltage Profile and Loss Minimization in Transmission Systems Using Nature Inspired Algorithms.

    Science.gov (United States)

    Ramamoorthy, Ambika; Ramachandran, Rajeswari

    2016-01-01

    Power grid becomes smarter nowadays along with technological development. The benefits of smart grid can be enhanced through the integration of renewable energy sources. In this paper, several studies have been made to reconfigure a conventional network into a smart grid. Amongst all the renewable sources, solar power takes the prominent position due to its availability in abundance. Proposed methodology presented in this paper is aimed at minimizing network power losses and at improving the voltage stability within the frame work of system operation and security constraints in a transmission system. Locations and capacities of DGs have a significant impact on the system losses in a transmission system. In this paper, combined nature inspired algorithms are presented for optimal location and sizing of DGs. This paper proposes a two-step optimization technique in order to integrate DG. In a first step, the best size of DG is determined through PSO metaheuristics and the results obtained through PSO is tested for reverse power flow by negative load approach to find possible bus locations. Then, optimal location is found by Loss Sensitivity Factor (LSF) and weak (WK) bus methods and the results are compared. In a second step, optimal sizing of DGs is determined by PSO, GSA, and hybrid PSOGSA algorithms. Apart from optimal sizing and siting of DGs, different scenarios with number of DGs (3, 4, and 5) and PQ capacities of DGs (P alone, Q alone, and P and Q both) are also analyzed and the results are analyzed in this paper. A detailed performance analysis is carried out on IEEE 30-bus system to demonstrate the effectiveness of the proposed methodology.

  12. Diurnal Variation in Gas Exchange: The Balance between Carbon Fixation and Water Loss.

    Science.gov (United States)

    Matthews, Jack S A; Vialet-Chabrand, Silvere R M; Lawson, Tracy

    2017-06-01

    Stomatal control of transpiration is critical for maintaining important processes, such as plant water status, leaf temperature, as well as permitting sufficient CO 2 diffusion into the leaf to maintain photosynthetic rates ( A ). Stomatal conductance often closely correlates with A and is thought to control the balance between water loss and carbon gain. It has been suggested that a mesophyll-driven signal coordinates A and stomatal conductance responses to maintain this relationship; however, the signal has yet to be fully elucidated. Despite this correlation under stable environmental conditions, the responses of both parameters vary spatially and temporally and are dependent on species, environment, and plant water status. Most current models neglect these aspects of gas exchange, although it is clear that they play a vital role in the balance of carbon fixation and water loss. Future efforts should consider the dynamic nature of whole-plant gas exchange and how it represents much more than the sum of its individual leaf-level components, and they should take into consideration the long-term effect on gas exchange over time. © 2017 American Society of Plant Biologists. All Rights Reserved.

  13. Simulation of water management for fodder beet to reduce yield losses under late season drought

    Directory of Open Access Journals (Sweden)

    T. Noreldin

    2016-12-01

    Full Text Available The objectives of this study were to calibrate CropSyst model for fodder beet grown under full and late season drought and to use the simulation results to analyze the relationship between irrigation amount and yield, as well as in water management to reduce yield losses under full and late season drought. For this reason, two field experiments were implemented at El-Serw Agricultural Research Station in Demiatte governorate, during 2011/12 and 2012/13 growing seasons. Two irrigation treatments were studied: full irrigation and late season drought. The model was calibrated using the data obtained from the two seasons. Results indicated that the reduction in fodder beet yield under late season drought was 11 and 12% in 2011/12 and 2012/13 growing seasons, respectively. Calibration of CropSyst revealed that the percentage of difference between measured and predicted values were low in both growing seasons. The results also indicated that changing irrigation schedule after examining water stress index under full and late season drought led to increase in fodder beet yield, as well as water and land productivity. Thus, CropSyst model can give insight into when to apply irrigation water to minimize yield losses under late season drought.

  14. Transfer, loss and physical processing of water in hit-and-run collisions of planetary embryos

    Science.gov (United States)

    Burger, C.; Maindl, T. I.; Schäfer, C. M.

    2018-01-01

    Collisions between large, similar-sized bodies are believed to shape the final characteristics and composition of terrestrial planets. Their inventories of volatiles such as water are either delivered or at least significantly modified by such events. Besides the transition from accretion to erosion with increasing impact velocity, similar-sized collisions can also result in hit-and-run outcomes for sufficiently oblique impact angles and large enough projectile-to-target mass ratios. We study volatile transfer and loss focusing on hit-and-run encounters by means of smooth particle hydrodynamics simulations, including all main parameters: impact velocity, impact angle, mass ratio and also the total colliding mass. We find a broad range of overall water losses, up to 75% in the most energetic hit-and-run events, and confirm the much more severe consequences for the smaller body also for stripping of volatile layers. Transfer of water between projectile and target inventories is found to be mostly rather inefficient, and final water contents are dominated by pre-collision inventories reduced by impact losses, for similar pre-collision water mass fractions. Comparison with our numerical results shows that current collision outcome models are not accurate enough to reliably predict these composition changes in hit-and-run events. To also account for non-mechanical losses, we estimate the amount of collisionally vaporized water over a broad range of masses and find that these contributions are particularly important in collisions of ˜ Mars-sized bodies, with sufficiently high impact energies, but still relatively low gravity. Our results clearly indicate that the cumulative effect of several (hit-and-run) collisions can efficiently strip protoplanets of their volatile layers, especially the smaller body, as it might be common, e.g., for Earth-mass planets in systems with Super-Earths. An accurate model for stripping of volatiles that can be included in future planet

  15. Water motion and movement without sticking, weight loss and cross-contaminant in superhydrophobic glass tube.

    Science.gov (United States)

    Yuan, Jian-Jun; Jin, Ren-Hua

    2010-02-10

    We report that a simple fabrication of a superhydrophobic nanosurface consisted of a grass-like silica thin film on the inner wall of a glass tube and its feature in water motion and water movement. The glass tube with a superhydrophobic inner wall can make the water flow with friction-drag reduction and completely preventing water sticking. Transferring water by this tube did not cause weight loss at all. Therefore, aqueous solutions containing high content metal ions were cross-moved without washing the tube used and no cross-contamination occurred after cross-movement. Furthermore, in an inside diameter of 6.0 mm glass tube where the half-length of the inner surface is covered by superhydrophobic nanograss and the other half is an unmodified hydrophilic surface, the water droplets flowing down from the hydrophilic side can be stopped spontaneously at the hydrophilic-superhydrophobic boundary as if there is an invisible flow-stopping fence built inside the glass tube.

  16. Determination of water vapor transmission rate (WVTR) of HDPE bottles for pharmaceutical products.

    Science.gov (United States)

    Chen, Yisheng; Li, Yanxia

    2008-06-24

    The objective of this study was to investigate the effects of experimental conditions for measuring the water vapor transmission rate (WVTR) of high-density polyethylene (HDPE) bottles using a steady-state sorption method. Bottles were filled with desiccant, closed with caps and heat induction sealed, and then stored in stability chambers at controlled temperature and relative humidity. Weight gain of the bottles was determined every 1 or 2 weeks until a linear weight gain profile was obtained. WVTR of the bottles was determined from the slope of the linear portion of the weight gain versus time profile. The effects of desiccants and temperature/humidity were studied. Results show that, with a sufficient amount of anhydrous calcium chloride in bottles, a negligibly low and sufficiently constant headspace humidity is maintained, and a steady-state permeation rate is achieved. For all 8 sizes of bottles used in this study, steady-state was achieved in 1 or 2 weeks after the experiment was started. This method provided reproducible WVTR data for HDPE bottles. Apparent moisture permeability of all 8 sizes of bottles was (2.3+/-0.3)x10(-7), (2.6+/-0.2)x10(-7), and (3.4+/-0.2)x10(-7)cm(2)/s at 25 degrees C, 30 degrees C, 40 degrees C, respectively. Moisture permeability determined from the current study was similar to data reported in the literature, indicating that the steady-state weight gain method can be used to obtain reliable WVTR of containers for pharmaceutical products.

  17. Baking loss of bread with special emphasis on increasing water holding capacity.

    Science.gov (United States)

    Kotoki, D; Deka, S C

    2010-01-01

    Potato flour (PF), hydroxypropyl methylcellulose (HPMC) and honey were used as baking agents and their effects on baking loss and sensory quality were studied. PF at 1, 2 and 4% levels decreased baking loss followed by HPMC and honey. Water absorption was substantially high with the HPMC (70.8-80.8%) and PF (61.7-71.7%) compared to honey and normal standard bread. PF incorporation increased shelf-life (6-7 days) as compared to HPMC and honey. HPMC incorporated bread had higher moisture content (36.8-38.0%) followed by PF (34.5-35.8%) and honey (34.7%). The ash content was in the order of PF (1%) > honey (4%) > PF (2%) > normal bread > HPMC (0.5 g) > PF (4%) > HPMC (1 g) > HPMC (1.5 g). PF incorporated bread had sensorily highest acceptance followed by HPMC and honey.

  18. Electrolyte-carbohydrate beverage prevents water loss in the early stage of high altitude training.

    Science.gov (United States)

    Yanagisawa, Kae; Ito, Osamu; Nagai, Satsuki; Onishi, Shohei

    2012-01-01

    To prevent water loss in the early stage of high altitude training, we focused on the effect of electrolyte-carbohydrate beverage (EC). Subjects were 16 male university students who belonged to a ski club. They had ski training at an altitude of 1,800 m. The water (WT) group drank only water, and the EC group drank only an electrolyte-carbohydrate beverage. They arrived at the training site in the late afternoon. The study started at 7 pm on the day of arrival and continued until noon of the 4(th) day. In the first 12 hours, 1 L of beverages were given. On the second and third days, 2.5 L of beverages were given. All subjects ate the same meals. Each morning while in fasting condition, subjects were weighed and blood was withdrawn for various parameters (hemoglobin, hematocrit, sodium, potassium and aldosterone). Urine was collected at 12 hour intervals for a total 60 hours (5 times). The urine volume, gravity, sodium and potassium concentrations were measured. Peripheral oxygen saturation and heart rate were measured during sleep with a pulse oximeter. Liquid intakes in both groups were similar, hence the electrolytes intake was higher in the EC group than in the WT group. The total urine volume was lower in the EC group than in the WT group, respectively (paltitude training may be effective in decreasing urinary output and preventing loss of blood plasma volume.

  19. Dynamics of organic carbon losses by water erosion after biocrust removal

    Directory of Open Access Journals (Sweden)

    Cantón Yolanda

    2014-12-01

    Full Text Available In arid and semiarid ecosystems, plant interspaces are frequently covered by communities of cyanobacteria, algae, lichens and mosses, known as biocrusts. These crusts often act as runoff sources and are involved in soil stabilization and fertility, as they prevent erosion by water and wind, fix atmospheric C and N and contribute large amounts of C to soil. Their contribution to the C balance as photosynthetically active surfaces in arid and semiarid regions is receiving growing attention. However, very few studies have explicitly evaluated their contribution to organic carbon (OC lost from runoff and erosion, which is necessary to ascertain the role of biocrusts in the ecosystem C balance. Furthermore, biocrusts are not resilient to physical disturbances, which generally cause the loss of the biocrust and thus, an increase in runoff and erosion, dust emissions, and sediment and nutrient losses. The aim of this study was to find out the influence of biocrusts and their removal on dissolved and sediment organic carbon losses. One-hour extreme rainfall simulations (50 mm h-1 were performed on small plots set up on physical soil crusts and three types of biocrusts, representing a development gradient, and also on plots where these crusts were removed from. Runoff and erosion rates, dissolved organic carbon (DOC and organic carbon bonded to sediments (SdOC were measured during the simulated rain. Our results showed different SdOC and DOC for the different biocrusts and also that the presence of biocrusts substantially decreased total organic carbon (TOC (average 1.80±1.86 g m-2 compared to physical soil crusts (7.83±3.27 g m-2. Within biocrusts, TOC losses decreased as biocrusts developed, and erosion rates were lower. Thus, erosion drove TOC losses while no significant direct relationships were found between TOC losses and runoff. In both physical crusts and biocrusts, DOC and SdOC concentrations were higher during the first minutes after runoff

  20. PERBEDAAN SKIN CAPACITANCE DAN TRANSEPIDERMAL WATER LOSS PADA KULIT NON-LESI PASIEN PITIRIASIS VERSIKOLOR DENGAN NON-PITIRIASIS VERSIKOLOR

    Directory of Open Access Journals (Sweden)

    Satya Wydya Yenny

    2008-09-01

    Full Text Available AbstrakPada pitiriasis versikolor sering timbul kekambuhan, diduga salah satu penyebabnya adalah kelembaban kulit yang tinggi. Kelembaban kulit dipengaruhi oleh skin capacitance dan transepidermal water loss.Mengetahui skin capacitance dan transepidermal water loss kulit pasien pitiriasis versikolor dan perbedaannya dengan non-pitiriasis versikolor.Penelitian ini merupakan studi potong lintang perbandingan antar kelompok, yang dilakukan pada bulan September sampai dengan Nopember 2004 di Rumah Sakit Dr. Cipto Mangunkusumo. Subyek penelitian pasien pitiriasis versikolor dan kontrol non-pitiriasis versikolor yang dipasangkan dalam hal umur dan jenis kelamin dan dilakukan pemeriksaan skin capacitance dan transepidermal water loss pada kulit yang tampak normal di punggung menggunakan alat Tewameter/Corneometer 350.Dalam kurun waktu tersebut telah diperiksa sebanyak 32 pasien pitiriasis versikolor dan 32 kontrol non-pitiriasis versikolor. Skin capacitance pasien pitiriasis versikolor secara statistik tidak berbeda dengan kontrol non-pitiriasis versikolor (p = 0,730. Transepidermal water loss pasien pitiriasis versikolor secara bermakna lebih rendah dari pada kelompok kontrol non-pitiriasis versikolor (p = 0,000.Tidak ada perbedaan skin capacitance kulit pasien pitiriasis versikolor dengan non-pitiriasis versikolor. Transepidermal water loss kulit pasien pitiriasis versikolor lebih rendah daripada non-pitiriasis versikolor.Kata kunci: pitiriasis versikolor, skin capacitance, transepidermal water lossAbstractThe recurrence of pityriasis versicolor is high, it could be caused by high skin hydration. Skin hydration was influenced by skin capacitance and transepidermal water loss.ARTIKEL PENELITIAN168The purpose of this study was to compare the differences of the skin capacitance and transepidermal water loss between the pityriasis versicolor skin and healthy non-pityriasis versicolor skin.The design of this study was comparative cross-sectional study

  1. Evaluation of Control and Protection System for Loss of Electrical Power Supply System of Water-Cooling Nuclear Power Plant

    International Nuclear Information System (INIS)

    Suhaemi, Tjipta; Djen Djen; Setyono; Jambiar, Riswan; Rozali, Bang; Setyo P, Dwi; Tjahyono, Hendro

    2000-01-01

    Evaluation of control and protection system for loss of electrical power supply system of water-cooled nuclear power plant has been done. The loss of electrical power supply. The accident covered the loss of external electrical load and loss of ac power to the station auxiliaries. It is analysed by studying and observing the mechanism of electrical power system and mechanism of related control and protection system. The are two condition used in the evaluation i e without turbine trip and with turbine trip. From the evaluation it is concluded that the control and protection system can handled the failure caused by the loss of electrical power system

  2. Diet change and food loss reduction: What is their combined impact on global water use and scarcity?

    Science.gov (United States)

    Jalava, Mika; Guillaume, Joseph H. A.; Kummu, Matti; Porkka, Miina; Siebert, Stefan; Varis, Olli

    2016-03-01

    There is a pressing need to improve food security and reduce environmental impacts of agricultural production globally. Two of the proposed measures are diet change from animal-based to plant-based foodstuffs and reduction of food losses and waste. These two measures are linked, as diet change affects production and consumption of foodstuffs and consequently loss processes through their different water footprints and loss percentages. This paper takes this link into account for the first time and provides an assessment of the combined potential contribution of diet change and food loss reduction for reducing water footprints and water scarcity. We apply scenarios in which we change diets to follow basic dietary recommendations, limit animal-based protein intake to 25% of total protein intake, and halve food losses to study single and combined effects of diet change and loss reduction. Dietary recommendations alone would achieve 6% and 7% reductions of blue and green water consumption, respectively, while changing diets to contain less animal products would result in savings of 11% and 18%, respectively. Halving food loss would alone achieve 12% reductions for both blue and green water. Combining the measures would reduce water consumption by 23% and 28%, respectively, lowering water scarcity in areas with a population of over 600 million. At a global scale, effects of diet change and loss reduction were synergistic with loss reductions being more effective under changed diet. This demonstrates the importance of considering the link between diet change and loss reduction in assessments of food security and resource use.

  3. Foraging Activity Pattern Is Shaped by Water Loss Rates in a Diurnal Desert Rodent.

    Science.gov (United States)

    Levy, Ofir; Dayan, Tamar; Porter, Warren P; Kronfeld-Schor, Noga

    2016-08-01

    Although animals fine-tune their activity to avoid excess heat, we still lack a mechanistic understanding of such behaviors. As the global climate changes, such understanding is particularly important for projecting shifts in the activity patterns of populations and communities. We studied how foraging decisions vary with biotic and abiotic pressures. By tracking the foraging behavior of diurnal desert spiny mice in their natural habitat and estimating the energy and water costs and benefits of foraging, we asked how risk management and thermoregulatory requirements affect foraging decisions. We found that water requirements had the strongest effect on the observed foraging decisions. In their arid environment, mice often lose water while foraging for seeds and cease foraging even at high energetic returns when water loss is high. Mice also foraged more often when energy expenditure was high and for longer times under high seed densities and low predation risks. Gaining insight into both energy and water balance will be crucial to understanding the forces exerted by changing climatic conditions on animal energetics, behavior, and ecology.

  4. Temperatures in a runaway greenhouse on the evolving Venus Implications for water loss

    Science.gov (United States)

    Watson, A. J.; Donahue, T. M.; Kuhn, W. R.

    1984-01-01

    Some aspects of the temperature structure of a runaway greenhouse on Venus are examined using one-dimensional radiative transfer techniques. It is found that there generally is a region high in the atmosphere where condensation and cloud formation can occur, while deep in the atmosphere the gas is strongly unsaturated with respect to water vapor. The necessity of including clouds introduces considerably uncertainty into the calculation of surface temperatures. Under reasonable assumptions concerning the clouds, temperatures deep in the atmosphere are high enough to produce a plastic or even molten surface, which may significantly ease the problem of explaining the loss of oxygen.

  5. Impacts of Soil and Water Conservation Practices on Crop Yield, Run-off, Soil Loss and Nutrient Loss in Ethiopia: Review and Synthesis.

    Science.gov (United States)

    Adimassu, Zenebe; Langan, Simon; Johnston, Robyn; Mekuria, Wolde; Amede, Tilahun

    2017-01-01

    Research results published regarding the impact of soil and water conservation practices in the highland areas of Ethiopia have been inconsistent and scattered. In this paper, a detailed review and synthesis is reported that was conducted to identify the impacts of soil and water conservation practices on crop yield, surface run-off, soil loss, nutrient loss, and the economic viability, as well as to discuss the implications for an integrated approach and ecosystem services. The review and synthesis showed that most physical soil and water conservation practices such as soil bunds and stone bunds were very effective in reducing run-off, soil erosion and nutrient depletion. Despite these positive impacts on these services, the impact of physical soil and water conservation practices on crop yield was negative mainly due to the reduction of effective cultivable area by soil/stone bunds. In contrast, most agronomic soil and water conservation practices increase crop yield and reduce run-off and soil losses. This implies that integrating physical soil and water conservation practices with agronomic soil and water conservation practices are essential to increase both provisioning and regulating ecosystem services. Additionally, effective use of unutilized land (the area occupied by bunds) by planting multipurpose grasses and trees on the bunds may offset the yield lost due to a reduction in planting area. If high value grasses and trees can be grown on this land, farmers can harvest fodder for animals or fuel wood, both in scarce supply in Ethiopia. Growing of these grasses and trees can also help the stability of the bunds and reduce maintenance cost. Economic feasibility analysis also showed that, soil and water conservation practices became economically more viable if physical and agronomic soil and water conservation practices are integrated.

  6. Effect of National-Scale Afforestation on Forest Water Supply and Soil Loss in South Korea, 1971–2010

    Directory of Open Access Journals (Sweden)

    Gang Sun Kim

    2017-06-01

    Full Text Available Afforestation of forests in South Korea may provide an example of the benefit of afforestation on precipitation storage and erosion control. In this study, we presented the effects of afforestation on water supply and soil loss prevention. A spatio-temporal simulation of forest water yield and soil loss was performed from 1971–2010 using InVEST water yield and SWAT models. A forest stock change map was produced by combining land cover data and National Forest Inventory data. The forest water yield increased about twice with changes in forest stock and climate from 1971–2010 and showed a spatially homogeneous water supply capacity. In the same period, the soil loss decreased more than three times, and the volatility of soil loss, in the 2010s, was smaller than before. The analysis of the change in forest stock without considering climate change showed an increase of 43% in forest water yield and a decrease of 87% in soil loss. An increase in precipitation increased the water yield, but also increased the soil loss volume. A change in forest stock led to positive changes in both. This study presents functional positive effects of the afforestation program in South Korea that can be useful in various afforestation programs in other countries.

  7. Review of boiling water reactor small break loss of coolant accidents

    International Nuclear Information System (INIS)

    Gururaj, P.M.; Dua, S.S.; Rao, A.S.

    1981-01-01

    This paper presents a review of the analytical and the experimental work performed by the General Electric Company to determine the performance of boiling water reactors (BWR) following postulated small break accidents (SBA). This review paper addresses the following issues: (1) the response of the BWR following small loss of inventory events; (2) methods of analysis and their justification; (3) necessity, if any, of operator action and the length of time available in which such action can be performed; and (4) operator interface following the SBA event. The results from these SBA studies for different BWR product lines show that even with the multiple system failures assumed, the BWR can successfully withstand an SBA. For a typical BWR/6, it takes the failure of 13 water delivery pumps to cause any significant core heatup. The only operator actions determined to be necessary are simple ones and ample time is available to the operator to perform these actions, if needed

  8. Effects of Material Choice on Biocide Loss in Orion Water Storage Tanks

    Science.gov (United States)

    Wallace, W. T.; Wallace, S. L.; Gazda, D. B.; Lewis, J. F.

    2016-01-01

    When preparing for long-duration spaceflight missions, maintaining a safe supply of potable water is of the utmost importance. One major aspect of that is ensuring that microbial growth is minimized. Historically, this challenge has been addressed through the use of biocides. When using biocides, the choice of materials for the storage containers is important, because surface reactions can reduce biocide concentrations below their effective range. In the water storage system baselined for the Orion vehicle, the primary wetted materials are stainless steel (316 L) and a titanium alloy (Ti6Al4V). Previous testing with these materials has shown that the biocide selected for use in the system (ionic silver) will plate out rapidly upon initial wetting of the system. One potential approach for maintaining an adequate biocide concentration is to spike the water supply with high levels of biocide in an attempt to passivate the surface. To evaluate this hypothesis, samples of the wetted materials were tested individually and together to determine the relative loss of biocide under representative surface area-to-volume ratios after 24 hours. Additionally, we have analyzed the efficacy of disinfecting a system containing these materials by measuring reductions in bacterial counts in the same test conditions. Preliminary results indicate that the use of titanium, either individually or in combination with stainless steel, can result in over 95% loss of biocide, while less than 5% is lost when using stainless steel. In bacterial testing, viable organisms were recovered from samples exposed to the titanium coupons after 24 hours. By comparison, no organisms were recovered from the test vessels containing only stainless steel. These results indicate that titanium, while possessing some favorable attributes, may pose additional challenges when used in water storage tanks with ionic silver biocide.

  9. Water concentration/activity and loss of vitamins B1 and E in pork due to gamma radiation

    International Nuclear Information System (INIS)

    Fox, J.B. Jr.; Lakritz, L.; Kohout, K.M.; Thayer, D.W.

    1994-01-01

    When irradiated, increasing the water content of pork by partial rehydration of freeze-dried L. dorsi muscle resulted in increasing rate of thiamin loss from zero in dry tissue to ca 6%/kGy of irradiation in tissue with 70% water. Conversely, the rate of loss of alpha-tocopherol decreased from 44%/kGy at 0% to 32%/kGy at 70% water. Decreasing water activity in buffers or in ground or freeze-dried pork by salt or sucrose had no effect on rate of loss of either vitamin following irradiation. Salt decreased the loss of both vitamins in pork due to competition for the hydroxyl radical by chloride ions

  10. Reasons for loss to follow-up among mothers registered in a prevention-of-mother-to-child transmission program in rural Malawi.

    Science.gov (United States)

    Bwirire, L D; Fitzgerald, M; Zachariah, R; Chikafa, V; Massaquoi, M; Moens, M; Kamoto, K; Schouten, E J

    2008-12-01

    This study was conducted to identify reasons for a high and progressive loss to follow-up among HIV-positive mothers within a prevention-of-mother-to-child HIV transmission (PMTCT) program in a rural district hospital in Malawi. Three focus group discussions were conducted among a total of 25 antenatal and post-natal mothers as well as nurse midwives (median age 39 years, range 22-55 years). The main reasons for loss to follow-up included: (1) not being prepared for HIV testing and its implications before the antenatal clinic (ANC) visit; (2) fear of stigma, discrimination, household conflict and even divorce on disclosure of HIV status; (3) lack of support from husbands who do not want to undergo HIV testing; (4) the feeling that one is obliged to rely on artificial feeding, which is associated with social and cultural taboos; (5) long waiting times at the ANC; and (6) inability to afford transport costs related to the long distances to the hospital. This study reveals a number of community- and provider-related operational and cultural barriers hindering the overall acceptability of PMTCT that need to be addressed urgently. Mothers attending antenatal services need to be better informed and supported, at both community and health-provider level.

  11. Measurement of the vertical infiltration parameters and water redistribution in LRd and LEa soils by gamma-ray transmission technique

    International Nuclear Information System (INIS)

    Souza, A.D.B. de; Saito, H.; Appoloni, C.R.; Coimbra, M.M.; Parreira, P.S.

    1991-01-01

    The properties of soil water diffusivity and soil hydraulic conductivity of two horizons (0-20 cm and 20-40 cm) from Latossolo Roxo distrofico (LRd) and Latossolo Vermelho escuro (LEa) soil samples, have been measured in laboratory through the vertical infiltration and redistribution of water in soil columns. The moisture profile as a function of time for each position in the soil column were obtained with the gamma-ray transmission technique, using a sup(241)Am gamma-ray source, a Na (I) T1 scintillation detector and gamma spectrometry standard electronic. (author)

  12. Response of water deficit regime and soil amelioration on evapotranspiration loss and water use efficiency of maize (Zea mays l.) in subtropical northeastern Himalayas.

    Science.gov (United States)

    Marwein, M A; Choudhury, B U; Chakraborty, D; Kumar, M; Das, A; Rajkhowa, D J

    2017-05-01

    Rainfed maize production in the hilly ecosystem of Northeastern Himalayas often suffers from moisture and soil acidity induced abiotic stresses. The present study measured evapotranspiration loss (ET c ) of maize crop under controlled condition (pot experiment) of water deficit (W 25 -25 % and W 50 -50 % of field capacity soil moistures) and well watered (W 100  = 100 % of field capacity (FC)) regimes in strong acid soils (pH = 4.3) of the Northeastern Himalayan Region of India. The response of soil ameliorants (lime) and phosphorus (P) nutrition under differential water regimes on ET c losses and water use efficiency was also studied. The measured seasonal ET c loss varied from 124.3 to 270.9 mm across treatment combinations. Imposition of water deficit stress resulted in significant (p losses but was at the cost of delay in tasseling to silking, 47-65 % reduction in dry matter accumulation (DMA), 12-22 days shortening of grain formation period, and complete kernel abortion. Liming @ 4 t ha -1 significantly (p losses and DMA across water regimes but the magnitude of increase was higher in severely water deficit (W 25 ) regime. Unlike lime, P nutrition improved DMA only in well-watered regimes (W 100 ) while seasonal ET c loss was unaffected. Vegetative stage (tillering to tasseling) contributed the maximum ET c losses while weekly crop ET c loss was estimated highest during 11th-14th week after sowing (coincided with blistering stage) and then declined. Water use efficiency estimated from dry matter produced per unit ET c losses and irrigation water used varied from 4.33 to 9.43 g dry matter kg -1  water and 4.21 to 8.56 g dry matter kg -1 , respectively. Among the input factors (water, P, and lime), water regime most strongly influenced the ET c loss, growth duration, grain formation, and water use efficiency of maize.

  13. Low mother-to-child HIV transmission rate but high loss-to-follow-up among mothers and babies in Mandalay, Myanmar; a cohort study.

    Directory of Open Access Journals (Sweden)

    Khine Wut Yee Kyaw

    Full Text Available Loss-to-follow-up (LTFU throughout the Prevention of Mother-To-Child Transmission (PMTCT cascade remains one of the major threats to the success of PMTCT programs. In this study, we aimed to determine the mother-to-child transmission rate in a programmatic setting and to determine factors associated with LTFU among enrolled mothers and unfavorable outcomes among HIV-exposed babies which includes being HIV positive, death and LTFU.A retrospective cohort study reviewing routinely collected data in an Integrated HIV care program, Mandalay, Myanmar in June 2016.LTFU means mother/infant missing appointed visit for more than three months.Of 678 pregnant women enrolled in PMTCT program between March 2011 and June 2014, one stillbirth and 607 live births were recorded in this cohort. Of 457 HIV-exposed babies with HIV-test recorded at the end of the intervention, nine (2% were HIV-positive. Pregnant women's and exposed-babies' LTFU rate was 7 per 1000 person-years, and 10 per 1000 person-years respectively. PMTCT option B protocol was found to be significantly associate with maternal LTFU [adjusted Hazard Ratio (aHR 95% CI: 3.52 (1.38-8.96] when compare to mothers receiving option B+/lifelong antiretroviral therapy (ART. Weight <2.5 Kg at enrolment, receiving mixed-feeding, vaginal delivery and option B PMTCT protocol were significantly associated with unfavorable outcomes among exposed babies [aHR(95% CI: 5.40 (1.66-17.53, 5.91(1.68-20.84, 2.27 (1.22-4.22 and 2.33 (1.16-4.69 respectively].Mother-to-child HIV transmission rate in this public hospital-based program was lower than the 5% national target, which indicates a successful PMTCT intervention. However, a high proportion of HIV-infected mothers and exposed babies LTFU was recorded. Lifelong ART provision to HIV-positive pregnant women was shown to reduce exposed babies' LTFU, death and transmission rate (unfavorable outcomes in this setting. Lessons learned from this program could be used to

  14. Effects of cropping systems on water runoff, soil erosion and nutrient loss in the Moldavian Plateau, Romania

    Energy Technology Data Exchange (ETDEWEB)

    Ailincai, C.; Jitareanu, G.; Bucur, D.; Ailincai, D.; Raus, L.; Filipov, F.

    2009-07-01

    The experiments carried out at the Podu-lloaiei Agricultural Research Sation, during 1986-2008, had the following objectives: the study of water runoff and soil losses, by erosion, in different crops; the annual rate of erosion process under the influence of anti-erosion protection of different crops; the influence of water runoff and soil erosion on losses of organic matter and mineral elements from soil. (Author) 7 refs.

  15. Effects of cropping systems on water runoff, soil erosion and nutrient loss in the Moldavian Plateau, Romania

    International Nuclear Information System (INIS)

    Ailincai, C.; Jitareanu, G.; Bucur, D.; Ailincai, D.; Raus, L.; Filipov, F.

    2009-01-01

    The experiments carried out at the Podu-lloaiei Agricultural Research Sation, during 1986-2008, had the following objectives: the study of water runoff and soil losses, by erosion, in different crops; the annual rate of erosion process under the influence of anti-erosion protection of different crops; the influence of water runoff and soil erosion on losses of organic matter and mineral elements from soil. (Author) 7 refs.

  16. Analysis of loss-of-coolant accidents in pressurized water reactors

    International Nuclear Information System (INIS)

    Moldaschl, H.

    1982-01-01

    Analysis of loss-of-coolant accidents in pressurized water reactors -Quantification of the influence of leak size, control assembly worth, boron concentration and initial power by a dynamic operations criterion. Neutronic and thermohydraulic behaviour of a pressurized water reactor during a loss-of-coolant accident (LOCA) is mainly influenced by -change of fuel temperature, -void in the primary coolant. They cause a local stabilization of power density, that means that also in the case of small leaks local void is the main stabilization effect. As a consequence the increase of fuel temperature remains very small even under extremely hypothetical assumptions: small leak, positive reactivity feedback (positive coolant temperature coefficient, negative density coefficient) at the beginning of the accident and all control assemblies getting stuck. Restrictions which have been valid up to now for permitted start-up conditions to fulfill inherent safety requirements can be lossened substantially by a dynamic operations criterion. Burnable poisons for compensation of reactivity theorefore can be omitted. (orig.)

  17. Simulation of small break loss of coolant accident in pressurized water reactor (PWR)

    International Nuclear Information System (INIS)

    Abass, N. M. N.

    2012-02-01

    A major safety concern in pressurized-water-reactor (PWR) design is the loss-of-coolant accident (LOCA),in which a break in the primary coolant circuit leads to depressurization, boiling of the coolant, consequent reduced cooling of the reactor core, and , unless remedial measures are taken, overheating of the fuel rods. This concern has led to the development of several simulators for safety analysis. This study demonstrates how the passive and active safety systems in conventional and advanced PWR behave during the small break loss of Coolant Accident (SBLOCA). The consequences of SBOLOCA have been simulated using IAEA Generic pressurized Water Reactor Simulator (GPWRS) and personal Computer Transient analyzer (PCTRAN) . The results were presented and discussed. The study has confirmed the major safety advantage of passive plants versus conventional PWRs is that the passive safety systems provide long-term core cooling and decay heat removal without the need for operator actions and without reliance on active safety-related system. (Author)

  18. Agarwood Waste as A New Fluid Loss Control Agent in Water-based Drilling Fluid

    Directory of Open Access Journals (Sweden)

    Azlinda Azizi

    2013-10-01

    Full Text Available Normal 0 false false false IN X-NONE X-NONE MicrosoftInternetExplorer4 Agarwood has been used widely in various ways, including traditional medicine and art. The usage of agarwood has grown broader in modern times include in therapeutic medicines and perfumery. In this paper the agarwood waste has been explored to be used as a fluid loss control agent to control fluid loss without affecting the drilling fluid rheological properties which are density, pH, viscosity, yield point and gel strength. Agarwood waste was used as an additive in the drilling fluid system due to its unique characteristic. Rheological and filtration measurements were performed on the formulated water-based drilling fluid. Formulations of a base solution of fresh water, sodium hydroxide, bentonite, barite, and xanthan gum were presented. The performance of the agarwood waste as the fluid loss control agent was compared with based fluid formulation and water-based drilling fluid with treating with conventional fluid loss control agent (starch. The filtrate volume of drilling fluid with agarwood waste was about 13 ml while for drilling fluid with conventional fluid loss control agent, starch gave 12 ml of filtrate volume after undergoing filtration test by using LPLT filter press. The performance of drilling fluid with agarwood was efficient as drilling fluid with starch. /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-priority:99; mso-style-qformat:yes; mso-style-parent:""; mso-padding-alt:0cm 5.4pt 0cm 5.4pt; mso-para-margin:0cm; mso-para-margin-bottom:.0001pt; mso-pagination:widow-orphan; font-size:11.0pt; font-family:"Calibri","sans-serif"; mso-ascii-font-family:Calibri; mso-ascii-theme-font:minor-latin; mso-fareast-font-family:"Times New Roman"; mso-fareast-theme-font:minor-fareast; mso-hansi-font-family:Calibri; mso-hansi-theme-font:minor-latin; mso

  19. Not all water becomes wine: Sulfur inputs as an opportune tracer of hydrochemical losses from vineyards

    Science.gov (United States)

    Hinckley, Eve-Lyn S.; Kendall, Carol; Loague, Keith

    2008-07-01

    California's widespread and economically important vineyards offer substantial opportunities to understand the interface between hydrology and biogeochemistry in agricultural soils. The common use of native sulfur (S) as a fumigant or soil additive provides a novel way to isotopically differentiate among sulfate (SO42-) pools, allowing the estimation of water and SO42- budgets. The objectives of this study were (1) to characterize the near-surface hydrological flow paths in a vineyard during irrigation and storm events and (2) to determine how those flow paths affect the fate and transport of SO42- across seasons. Integrating hydrological theory with measurements of SO42- concentration and sulfate-S isotopic ratios (expressed as [SO42-] and δ34S, respectively) in inputs, soil water, and leachate provided a means of determining flow paths. Low [SO42-] and δ34S in leachate during 4-h irrigation events reflect minimal engagement of the soil matrix, indicating that preferential flow was the dominant path for water in the near surface. In contrast, high [SO42-] and δ34S values during 8-h irrigation and storm events reflect near-complete engagement of the soil matrix, indicating that lateral flow was the dominant pathway. Because hydrologic response and SO42- mobility are tightly coupled in these soils, the magnitude of water fluxes through the near surface controls S cycling both on and off site. These results indicate that preferential flow is an important loss pathway to consider in managing both water resources and water quality (reactive elements) in vineyard land use systems.

  20. Not all water becomes wine: Sulfur inputs as an opportune tracer of hydrochemical losses from vineyards

    Science.gov (United States)

    Hinckley, Eve-Lyn S.; Kendall, Carol; Loague, Keith

    2009-01-01

    California's widespread and economically important vineyards offer substantial opportunities to understand the interface between hydrology and biogeochemistry in agricultural soils. The common use of native sulfur (S) as a fumigant or soil additive provides a novel way to isotopically differentiate among sulfate (SO42−) pools, allowing the estimation of water and SO42− budgets. The objectives of this study were (1) to characterize the near‐surface hydrological flow paths in a vineyard during irrigation and storm events and (2) to determine how those flow paths affect the fate and transport of SO42− across seasons. Integrating hydrological theory with measurements of SO42−concentration and sulfate‐S isotopic ratios (expressed as [SO42−] and δ34S, respectively) in inputs, soil water, and leachate provided a means of determining flow paths. Low [SO42−] and δ34S in leachate during 4‐h irrigation events reflect minimal engagement of the soil matrix, indicating that preferential flow was the dominant path for water in the near surface. In contrast, high [SO42−] and δ34S values during 8‐h irrigation and storm events reflect near‐complete engagement of the soil matrix, indicating that lateral flow was the dominant pathway. Because hydrologic response and SO42− mobility are tightly coupled in these soils, the magnitude of water fluxes through the near surface controls S cycling both on and off site. These results indicate that preferential flow is an important loss pathway to consider in managing both water resources and water quality (reactive elements) in vineyard land use systems.

  1. Incidence of Avian Influenza in Adamawa State, Nigeria: The Epidemiology, Economic Losses and the Possible Role of Wild Birds in the Transmission of the Disease

    Science.gov (United States)

    Ja`Afar-Furo, M. R.; Balla, H. G.; Tahir, A. S.; Haskainu, C.

    Reducing the huge economic losses due to diseases in poultry as the second largest industry in Nigeria after oil means improving the protein intake of the majority. Similarly, this will also promotes a steady income for the teeming farmers. This study investigated the incidence of the lethal avian influenza in Adamawa State, Nigeria, with particular emphasis on the socio-economic and cultural activities of the poultry farmers, economic losses and the possible role of wild birds in the transmission of the disease. Data were collected from 316 and 458 direct and indirect respondents, respectively, from 6 affected villages and a town in 2 Local Government Areas (LGAs): Girei and Yola-North. Results revealed that a larger (25.71%) proportion of the respondents fell within the age range of 31-40 years, with majority (54.91%) as females. While the bulk (54.65%) of the respondents were illiterates, 95.47% of the direct respondents derived their incomes from crop production, whereas 59.17% of the indirect respondents from livestock rearing. About 26,049 birds worth N13, 454,800.00 was cumulative economic loss incurred by the poultry farmers, whereas that of the government was put at N1, 119,781.10. Of the mortalities experienced in the wildlife before the outbreak of the disease, Bubulcus ibis (64.29) and Tadarida nigeriae (86.36) were the highest. The study recommends a massive rural extension on Poultry Production with absolute biosecurity, involving all stakeholders (Veterinary Surgeons, Animal Scientists/health workers, wildlife specialists, Agricultural Economists, Information Officers etc.) in a collaborative form for high synergistic effects.

  2. Sensitivity Analysis of Core Damage by Loss of Auxiliary Feed Water during the Extended Loss of All AC Power

    Energy Technology Data Exchange (ETDEWEB)

    Jeon, Woo Jae; Chung, Soon Il; Hwang, Su Hyun; Lee, Kyung Jin; Lee, Byung Chul [FNC Tech., Yongin (Korea, Republic of); Yun, Duk Joo; Lee, Seung Chan [Korea Hydro and Nuclear Power Co. Ltd., Daejeon (Korea, Republic of)

    2015-10-15

    In this study, the reactor core damage time for OPR1000 type Nuclear Power Plant (NPP) was analyzed to develop a strategy to handle ELAP and to apply to the EOP. The reactor core damage time in the ELAP condition was calculated according to the time of Auxiliary Feedwater (AFW) loss. Fukushima accident was caused by long hours of Station Black Out (SBO) caused by natural disaster beyond Design Based Accident (DBA) criteria. It led to the reactor core damage. After the accident, the regulatory authorities of each country (Japan, US, EU, IAEA, and etc.) recommended developing the necessary systems and strategies in order to cover up the Extended Loss of All AC Power (ELAP) such as one occurred in the Fukushima accident. And the need of procedure or guideline to cope with ELAP has been raised through the stress test for Wolsong Nuclear Power Plant unit 1. Current Emergency Operating Procedures (EOP) used in domestic nuclear power plant are seemed to be insufficient to cope with ELAP. Therefore, it has been required to be improved. As the result, the time of AFW loss in the ELAP condition influences greatly on core damage time.

  3. A Study on the Rate of Events and Water Loss in Water Distribution Network of Azna, Lorstan, Iran during 2008-2014 and Its Associated Factors

    Directory of Open Access Journals (Sweden)

    Mohammad Adeli

    2016-12-01

    Full Text Available Introduction and purpose: One of the problems of water distribution systems is loss of large volumes of water due to the occurrence of various events, which incurs a huge financial loss. Regarding this, the aim of the present study was to investigate the rate of events and water loss in the water distribution system and its related factors in Azna, Lorestan province, Iran, during 2008-2014. Methods: This cross-sectional study was conducted using census method, surveys, and field data collection. The amount of water production and consumption, the volumes of water loss, the number of accidents, type of pipe, pressure zone, as well as the age and length of the pipes recorded during 2008- 2014 were studied and analyzed. Results: According to the results, the highest (34.48% and lowest (20.57% amount of water losses happened in 2008 and 2014, respectively. High pressures in water systems had significant relationship with the number of events as well as the amount of water loss and water consumption. In addition, higher length and age of the pipes had a direct correlation with increased number of events and water loss. Furthermore, the maximum number of events were found to occur in the pipe embranchment and galvanized pipes. Conclusion: This study showed that of events was directly related to the length and age of the pipes, the water pressure, and number of branches. Also water loss quantity can be reduced by applying suitable management techniques in different sections. Furthermore, the water loss can be significantly controlled by taking such measures as reducing the pressure in the high-pressure zones, timely replacement of old and inappropriate pipes, appropriate fixing of the pipes, replacement of the galvanized pipe, and standard implementation of pipes and fittings.

  4. Water consumption increases weight loss during a hypocaloric diet intervention in middle-aged and older adults.

    Science.gov (United States)

    Dennis, Elizabeth A; Dengo, Ana Laura; Comber, Dana L; Flack, Kyle D; Savla, Jyoti; Davy, Kevin P; Davy, Brenda M

    2010-02-01

    Water consumption acutely reduces meal energy intake (EI) among middle-aged and older adults. Our objectives were to determine if premeal water consumption facilitates weight loss among overweight/obese middle-aged and older adults, and to determine if the ability of premeal water consumption to reduce meal EI is sustained after a 12-week period of increased water consumption. Adults (n = 48; 55-75 years, BMI 25-40 kg/m(2)) were assigned to one of two groups: (i) hypocaloric diet + 500 ml water prior to each daily meal (water group), or (ii) hypocaloric diet alone (nonwater group). At baseline and week 12, each participant underwent two ad libitum test meals: (i) no preload (NP), and (ii) 500 ml water preload (WP). Meal EI was assessed at each test meal and body weight was assessed weekly for 12 weeks. Weight loss was ~2 kg greater in the water group than in the nonwater group, and the water group (beta = -0.87, P hypocaloric diet, consuming 500 ml water prior to each main meal leads to greater weight loss than a hypocaloric diet alone in middle-aged and older adults. This may be due in part to an acute reduction in meal EI following water ingestion.

  5. A Preliminary Study on Rainfall Interception Loss and Water Yield Analysis on Arabica Coffee Plants in Central Aceh Regency, Indonesia

    Directory of Open Access Journals (Sweden)

    Reza Benara

    2012-12-01

    Full Text Available Rainfall interception loss from plants or trees can reduce a net rainfall as source of water yield. The amount of rainfall interception loss depends on kinds of plants and hydro-meteorological characteristics. Therefore, it is important to study rainfall interception loss such as from Arabica Coffee plantation which is as main agricultural commodity for Central Aceh Regency. In this study, rainfall interception loss from Arabica Coffee plants was studied in Kebet Village of Central Aceh Regency, Indonesia from January 20 to March 9, 2011. Arabica coffee plants used in this study was 15 years old, height of 1.5 m and canopy of 4.567 m2. Rainfall interception loss was determined based on water balance approach of daily rainfall, throughfall, and stemflow data. Empirical regression equation between rainfall interception loss and rainfall were adopted as a model to estimate rainfall interception loss from Arabica Coffee plantation, which the coefficient of correlation, r is 0.98. In water yield analysis, this formula was applied and founded that Arabica Coffee plants intercept 76% of annual rainfall or it leaved over annual net rainfall 24% of annual rainfall. Using this net rainfall, water yield produced from Paya Bener River which is the catchment area covered by Arabica Coffee plantation was analyzed in a planning of water supply project for water needs domestic of 3 sub-districts in Central Aceh Regency. Based on increasing population until year of 2025, the results showed that the water yield will be not enough from year of 2015. However, if the catchment area is covered by forest, the water yield is still enough until year of 2025

  6. Exposure to low-dose barium by drinking water causes hearing loss in mice.

    Science.gov (United States)

    Ohgami, Nobutaka; Hori, Sohjiro; Ohgami, Kyoko; Tamura, Haruka; Tsuzuki, Toyonori; Ohnuma, Shoko; Kato, Masashi

    2012-10-01

    We continuously ingest barium as a general element by drinking water and foods in our daily life. Exposure to high-dose barium (>100mg/kg/day) has been shown to cause physiological impairments. Direct administration of barium to inner ears by vascular perfusion has been shown to cause physiological impairments in inner ears. However, the toxic influence of oral exposure to low-dose barium on hearing levels has not been clarified in vivo. We analyzed the toxic influence of oral exposure to low-dose barium on hearing levels and inner ears in mice. We orally administered barium at low doses of 0.14 and 1.4 mg/kg/day to wild-type ICR mice by drinking water. The doses are equivalent to and 10-fold higher than the limit level (0.7 mg/l) of WHO health-based guidelines for drinking water, respectively. After 2-week exposure, hearing levels were measured by auditory brain stem responses and inner ears were morphologically analyzed. After 2-month exposure, tissue distribution of barium was measured by inductively coupled plasma mass spectrometry. Low-dose barium in drinking water caused severe hearing loss in mice. Inner ears including inner and outer hair cells, stria vascularis and spiral ganglion neurons showed severe degeneration. The Barium-administered group showed significantly higher levels of barium in inner ears than those in the control group, while barium levels in bone did not show a significant difference between the two groups. Barium levels in other tissues including the cerebrum, cerebellum, heart, liver and kidney were undetectably low in both groups. Our results demonstrate for the first time that low-dose barium administered by drinking water specifically distributes to inner ears resulting in severe ototoxicity with degeneration of inner ears in mice. Copyright © 2012 Elsevier Inc. All rights reserved.

  7. A closed unventilated chamber for the measurement of transepidermal water loss.

    Science.gov (United States)

    Nuutinen, Jouni; Alanen, Esko; Autio, Pekka; Lahtinen, Marjo-Riitta; Harvima, Ilkka; Lahtinen, Tapani

    2003-05-01

    Open chamber systems for measuring transepidermal water loss (TEWL) have limitations related to ambient and body-induced airflows near the probe, probe size, measurement sites and angles, and measurement range. The aim of the present investigation was to develop a closed chamber system for the TEWL measurement without significant blocking of normal evaporation through the skin. Additionally, in order to use the evaporimeter to measure evaporation rates through other biological and non-biological specimens and in the field applications, a small portable, battery-operated device was a design criteria. A closed unventilated chamber (inner volume 2.0 cm(3) was constructed. For the skin measurement, the chamber with one side open (open surface area 1.0 cm(2) is placed on the skin. The skin application time was investigated at low and high evaporation rates in order to assess the blocking effect of the chamber on normal evaporation. From the rising linear part of the relative humidity (RH) in the chamber the slope was registered. The slope was calibrated into a TEWL value by evaporating water at different temperatures and measuring the water loss of heated samples with a laboratory scale. The closed chamber evaporation technique was compared with a conventional evaporimeter based on an open chamber method (DermaLab), Cortex Technology, Hadsund, Denmark). The reproducibility of the closed chamber method was measured with the water samples and with volar forearm and palm of the hand in 10 healthy volunteers. The skin application time varied between 7 and 9 s and the linear slope region between 3 and 5 s at the evaporation rates of 3-220 g/m(2) h. A correlation coefficient between the TEWL value from the closed chamber measurements and the readings of the laboratory scale was 0.99 (P measurements with the water samples was 4.0% at the evaporation rate of 40 g/m(2) h. A correlation coefficient of the TEWL values between the closed chamber and open chamber measurements was 0

  8. The association of drinking water quality and sewage disposal with Helicobacter pylori incidence in infants: the potential role of water-borne transmission.

    Science.gov (United States)

    Travis, Penny B; Goodman, Karen J; O'Rourke, Kathleen M; Groves, Frank D; Sinha, Debajyoti; Nicholas, Joyce S; VanDerslice, Jim; Lackland, Daniel; Mena, Kristina D

    2010-03-01

    The mode of transmission of Helicobacter pylori, a bacterium causing gastric cancer and peptic ulcer disease, is unknown although waterborne transmission is a likely pathway. This study investigated the hypothesis that access to treated water and a sanitary sewerage system reduces the H. pylori incidence rate, using data from 472 participants in a cohort study that followed children in Juarez, Mexico, and El Paso, Texas, from April 1998, with caretaker interviews and the urea breath test for detecting H. pylori infection at target intervals of six months from birth through 24 months of age. The unadjusted hazard ratio comparing bottled/vending machine water to a municipal water supply was 0.71 (95% confidence interval (CI): 0.50, 1.01) and comparing a municipal sewer connection to a septic tank or cesspool, 0.85 (95% CI: 0.60, 1.20). After adjustment for maternal education and country, the hazard ratios decreased slightly to 0.70 (95% confidence interval: 0.49, 1.00) and 0.77 (95% confidence interval: 0.50, 1.21), respectively. These results provide moderate support for potential waterborne transmission of H. pylori.

  9. Effects of centrifugation on transmembrane water loss from normal and pathologic erythrocytes

    Energy Technology Data Exchange (ETDEWEB)

    Kaperonis, A.A.; Chien, S.

    1989-02-01

    Plasma /sup 125/I-albumin was used as a marker of extracellular dilution in order to study the effect of high-speed centrifugation on transmembrane water distribution in several types of human red cells, including normal (AA), hemoglobin variants (beta A, AS, SC, beta S, and SS), and those from patients with hereditary spherocytosis. SS and AA erythrocytes were also examined for changes in intracellular hemoglobin concentration of three different density fractions and with increasing duration of spin. The minimum force and duration of centrifugation required to impair water permeability were found to vary with the red cell type, the anticoagulant used (heparin or EDTA), the initial hematocrit of the sample centrifuged, as well as among the individual erythrocyte fractions within the same sample. When subjecting pathologic erythrocytes to high-speed centrifugation, the /sup 125/I-albumin dilution technique can be used to determine whether the centrifugation procedure has led to an artifactual red cell water loss and to correct for this when it does occur. An abnormal membrane susceptibility to mechanical stress was demonstrated in erythrocytes from patients with hereditary spherocytosis and several hemoglobinopathies.

  10. Effects of centrifugation on transmembrane water loss from normal and pathologic erythrocytes

    International Nuclear Information System (INIS)

    Kaperonis, A.A.; Chien, S.

    1989-01-01

    Plasma 125 I-albumin was used as a marker of extracellular dilution in order to study the effect of high-speed centrifugation on transmembrane water distribution in several types of human red cells, including normal (AA), hemoglobin variants (beta A, AS, SC, beta S, and SS), and those from patients with hereditary spherocytosis. SS and AA erythrocytes were also examined for changes in intracellular hemoglobin concentration of three different density fractions and with increasing duration of spin. The minimum force and duration of centrifugation required to impair water permeability were found to vary with the red cell type, the anticoagulant used (heparin or EDTA), the initial hematocrit of the sample centrifuged, as well as among the individual erythrocyte fractions within the same sample. When subjecting pathologic erythrocytes to high-speed centrifugation, the 125 I-albumin dilution technique can be used to determine whether the centrifugation procedure has led to an artifactual red cell water loss and to correct for this when it does occur. An abnormal membrane susceptibility to mechanical stress was demonstrated in erythrocytes from patients with hereditary spherocytosis and several hemoglobinopathies

  11. Balancing Water Uptake and Loss through the Coordinated Regulation of Stomatal and Root Development.

    Directory of Open Access Journals (Sweden)

    Christopher Hepworth

    Full Text Available Root development is influenced by nutrient and water availabilities. Plants are able to adjust many attributes of their root in response to environmental signals including the size and shape of the primary root, lateral roots and root hairs. Here we investigated the response of roots to changes in the levels of leaf transpiration associated with altered stomatal frequency. We found that plants with high stomatal density and conductance produce a larger rooting area and as a result have enhanced phosphate uptake capacity whereas plants with low stomatal conductance produce a smaller root. Manipulating the growth environment of plants indicated that enhanced root growth is most likely a result of an increased demand for water rather than phosphate. Plants manipulated to have an increase or reduction in root hair growth show a reduction or increase respectively, in stomatal conductance and density. Our results demonstrate that plants can balance their water uptake and loss through coordinated regulation of both stomatal and root development.

  12. Changes in Transepidermal Water Loss and Skin Hydration according to Expression of Aquaporin-3 in Psoriasis

    Science.gov (United States)

    Lee, Young; Je, Young-Jin; Lee, Sang-Sin; Li, Zheng Jun; Choi, Dae-Kyoung; Kwon, Yoo-Bin; Sohn, Kyung-Cheol; Im, Myung; Seo, Young Joon

    2012-01-01

    Background Aquaporins (AQPs) are a family of water transporting proteins present in many mammalian epithelial and endothelial cell types. Among the AQPs, AQP3 is known to be a water/glycerol transporter expressed in human skin. Objective The relationship between the expression level of AQP3 and transpidermal water loss (TEWL) in the lesional and peri-lesional skin of psoriasis-affected patients, and skin hydration in the lesional and peri-lesional skin of psoriasis patients, was investigated. Methods The expression of AQP3 in psoriasis-affected and healthy control skin was determined using immunohistochemical and immunofluroscence staining. TEWL and skin hydration were measured using a Tewameter® TM210 (Courage & Khazaka, Cologne, Germany) and a Corneometer® CM 820 (Courage & Khazaka), respectively. Results AQP3 was mainly expressed in the plasma membrane of stratum corneum and the stratum spinosum in normal epidermis. Unlike the normal epidermis, AQP3 showed decreased expression in the lesional and peri-lesional epidermis of psoriasis. TEWL was increased, and skin hydration was decreased, in the lesional and peri-lesional skin of psoriasis patients, compared with the healthy control sample. Conclusion Although various factors contribute to reduced skin hydration in the lesional and peri-lesional skin of psoriasis, AQP3 appears to be a key factor in the skin dehydration of psoriasis-affected skin. PMID:22577267

  13. Evaluating radon loss from water during storage in standard PET, bio-based PET, and PLA bottles

    International Nuclear Information System (INIS)

    Lucchetti, Carlo; De Simone, Gabriele; Galli, Gianfranco; Tuccimei, Paola

    2016-01-01

    Polyethylene terephthalate (PET) and polylactic acid (PLA) bottles were tested to evaluate radon loss from water during 15 days of storage. PET bottles (lower surface/volume-ratio vials) lost 0.4–7.1% of initial radon, whereas PLA bottles lost 3.7% of it. PET bottles with volume of 0.5 L, lower surface/weight ratio, and hence higher thickness display proportionally reduced radon loss. Corrections for dissolved radium are needed during analyses. Formulas for calculating degassing efficiency and water interference on electrostatic collections are developed. - Highlights: • Radon loss from water during storage in polyethylene terephthalate (PET) and polylactic acid (PLA) bottles was evaluated. • Surface/volume ratio and thickness of plastic materials were studied. • A correction for dissolved radium concentration was applied to estimate gas loss. • Proper corrections for degassing efficiency of aerators were developed. • The interference of H 2 O on radon daughter electrostatic collection was quantified.

  14. Development of Radiation-Resistant In-Water Wireless Transmission System Using Light Emitting Diodes and Photo Diodes

    Science.gov (United States)

    Takeuchi, T.; Shibata, H.; Otsuka, N.; Uehara, T.; Tsuchiya, K.; Shibagaki, T.; Komanome, H.

    2016-10-01

    Several kinds of commercially available light emitting diodes (LED) and photo diodes (PD) were irradiated with 60Co gamma ray up to 1 MGy for development of a radiation-resistant in-water wireless transmission system using visible light. The lens parts of the LEDs turned brown by the irradiation and their colors became dark with the absorbed dose. The total luminous fluxes decreased with the absorbed dose and the LED with shorter emission wavelength had the higher decrease rate. Meanwhile, the current-voltage characteristics hardly changed. These results indicate that the decreases of the total luminous flux of the LEDs were mainly caused not by the degradation of the semiconductor parts but by the coloring of the lens parts by the irradiation. On the other hand, the light sensitivities of the PDs decreased with the absorbed dose. The PDs with the window part which turned a darker color had the higher decrease rate. These results indicate that the decreases of light sensitivities of the PDs were also mainly caused by the coloring of the resin parts by the irradiation. If the wireless transmission is performed using the candidate LED and PD between 5 meters in water, using a few LEDs and PDs, the PD's output current generated by the emission light of the LED is estimated to be detectable even considering the effects of the absorption of the light in water and the increased dark current by the irradiation. Therefore, a radiation resistant in-water transmission system can be constructed using commercially available LEDs and PDs in principle.

  15. The use of high vacuum soil vapor extraction to improve contaminant recovery from ground water zones of low transmissivity

    International Nuclear Information System (INIS)

    Brown, A.; Farrow, J.R.C.; Burgess, W.

    1996-01-01

    This study examines the potential for enhancing hydrocarbon contaminant mass recovery from ground water using high vacuum soil vapor extraction (SVE). The effectiveness of this form of remediation is compared with the effectiveness of conventional pump-and-treat. This study focuses on the performance of a high vacuum SVE system at two ground water monitoring wells (MW-17 and MW-65b) at a site in Santa Barbara, California, US. The site is a highly characterized site with vadose zone and ground water petroleum hydrocarbon contamination (gasoline). The ground water wells are located beyond a defined area of vadose zone soil contamination. Ground water hydrocarbon contamination [light non-aqueous phase liquid (LNAPL) and dissolved phase] is present at each of the wells. the ground water wells have been part of a low-flow, pump-and-treat, ground water treatment system (GWTS) since August, 1986. The low transmissivity of the aquifer sediments prevent flow rates above approximately 0.02 gpm (0.01 l/min) per well

  16. Study on severe accident induced by large break loss of coolant accident for pressureized water reactor

    International Nuclear Information System (INIS)

    Zhang Longfei; Zhang Dafa; Wang Shaoming

    2007-01-01

    Using the best estimate computer code SCDAP/RELAP5/MOD3.2 and taking US Westinghouse corporation Surry nuclear power plant as the reference object, a typical three-loop pressurized water reactor severe accident calculation model was established and 25 cm large break loss of coolant accident (LBLOCA) in cold and hot leg of primary loop induced core melt accident was analyzed. The calculated results show that core melt progression is fast and most of the core material melt and relocated to the lower plenum. The lower head of reactor pressure vessel failed at an early time and the cold leg break is more severe than the hot leg break in primary loop during LBLOCA. (authors)

  17. ESTIMATING ANNUAL SOIL LOSS BY WATER EROSION IN THE MIDDLE PRUT PLAIN, REPUBLIC OF MOLDOVA

    Directory of Open Access Journals (Sweden)

    TUDOR CASTRAVEŢ

    2012-11-01

    Full Text Available Estimating annual soil loss by water erosion in the middle Prut Plain, Republic of Moldova. Modern technology has provided efficient tools such as advanced models and Geographic Information Systems to facilitate decision making for environmental management. Studies at this subject are available in literature, ranging from those that use a simple model such as USLE to others of a more sophisticated nature. In this study the model selected (modified Universal Soil Loss Equation – USLE and the case itself is kept simple due to significant limitations in data on land processes. An effective investigation of soil loss by using GIS – USLE integration requires spatially distributed data on several parameters describing the terrain surface. Such parameters include topography, rainfall characteristics, soil types, vegetation, land use, and the similar. In Republic of Moldova data on most of these parameters are collected often on a local or individual basis, and therefore, a well-organized regional or basin-wide database is not available. In the Republic of Moldova soil erosion is often as high as 30 tons/ha/year and more than 1.4*106 ha run a potential risk of erosion (Summer & Diernhof, 2003. The model estimated an annual quantity of soil eroded ranging over the Prut River tributaries watersheds between the mean values of 6.2 and 20.4 t/ha/yr. Much of the areas are within the range 10-20 t/ha/yr. The highest values of the quantity of eroded soil is carried out on strong inclined slopes corresponding to areas with agricultural lands and herbaceous vegetation. The results have shown that GIS can be effectively used to investigate critical regions within a basin with respect to erosion.

  18. Technology Solutions for New and Existing Homes Case Study: Addressing Multifamily Piping Losses with Solar Hot Water

    Energy Technology Data Exchange (ETDEWEB)

    D. Springer, M. Seitzler, and C. Backman

    2016-12-01

    Sun Light & Power, a San Francisco Bay Area solar design-build contractor, teamed with the U.S. Department of Energy’s Building America partner the Alliance for Residential Building Innovation (ARBI) to study this heat-loss issue. The team added three-way valves to the solar water heating systems for two 40-unit multifamily buildings. In these systems, when the stored solar hot water is warmer than the recirculated hot water returning from the buildings, the valves divert the returning water to the solar storage tank instead of the water heater. This strategy allows solar-generated heat to be applied to recirculation heat loss in addition to heating water that is consumed by fixtures and appliances.

  19. Speckled eggs: water-loss and incubation behaviour in the great tit Parus major.

    Science.gov (United States)

    Higham, James P; Gosler, Andrew G

    2006-10-01

    Many small passerine birds worldwide lay white eggs speckled with red, brown and black protoporphyrin pigment spots (maculation). Unlike some patterns of avian eggshell pigmentation which clearly serve a crypsis or signalling function, the ubiquity of maculation among passerines suggests that its origins lie in another function, not specific to any particular ecological or behavioural group. Elsewhere, we have presented evidence that protoporphyrin pigments serve a structural function related to eggshell thickness and calcium availability: eggshell maculation in the great tit Parus major increases with decreasing soil calcium levels, pigments demarcate thinner areas of shell, and both the pigment intensity and distribution are related to shell thickness. Here we show that maculation also affects the rate of water loss from the egg during incubation (approximately Mass Loss per Day or MLD, which is critical to egg viability), but not that of unincubated eggs. We also demonstrate, both by observation and experiment, that the effect of female incubation behaviour on MLD compensates in some way for variation in egg characteristics, and that differences between females in the degree of such compensation are related to differences in clutch maculation. Our results suggest that, while a principal function of maculation in this species may be to strengthen the eggshell, it may also reduce eggshell permeability when large amounts of pigment are used, and that this necessitates a behavioural adjustment from the female during incubation. We discuss these findings and make further testable predictions from our model.

  20. Retention and loss of water extractable carbon in soils: effect of clay properties.

    Science.gov (United States)

    Nguyen, Trung-Ta; Marschner, Petra

    2014-02-01

    Clay sorption is important for organic carbon (C) sequestration in soils, but little is known about the effect of different clay properties on organic C sorption and release. To investigate the effect of clay content and properties on sorption, desorption and loss of water extractable organic C (WEOC), two experiments were conducted. In experiment 1, a loamy sand alone (native) or mixed with clay isolated from a surface or subsoil (78 and 96% clay) resulting in 90, 158 and 175 g clay kg(-1) soil. These soil treatments were leached with different WEOC concentrations, and then CO2 release was measured for 28 days followed by leaching with reverse osmosis water at the end of experiment. The second experiment was conducted to determine WEOC sorption and desorption of clays isolated from the loamy sand (native), surface soil and subsoil. Addition of clays isolated from surface and subsoil to sandy loam increased WEOC sorption and reduced C leaching and cumulative respiration in percentage of total organic C and WEOC added when expressed per g soil and per g clay. Compared to clays isolated from the surface and subsoil, the native clay had higher concentrations of illite and exchangeable Ca(2+), total organic C and a higher CEC but a lower extractable Fe/Al concentration. This indicates that compared to the clay isolated from the surface and the subsoil, the native clay had fewer potential WEOC binding sites because it had lower Fe/Al content thus lower number of binding sites and the existing binding sites are already occupied native organic matter. The results of this study suggest that in the soils used here, the impact of clay on WEOC sorption and loss is dependent on its indigenous organic carbon and Fe and/or Al concentrations whereas clay mineralogy, CEC, exchangeable Ca(2+) and surface area are less important. © 2013.

  1. Effect of cuticular abrasion and recovery on water loss rates in queens of the desert harvester ant Messor pergandei.

    Science.gov (United States)

    Johnson, Robert A; Kaiser, Alexander; Quinlan, Michael; Sharp, William

    2011-10-15

    Factors that affect water loss rates (WLRs) are poorly known for organisms in natural habitats. Seed-harvester ant queens provide an ideal system for examining such factors because WLRs for mated queens excavated from their incipient nests are twofold to threefold higher than those of alate queens. Indirect data suggest that this increase results from soil particles abrading the cuticle during nest excavation. This study provides direct support for the cuticle abrasion hypothesis by measuring total mass-specific WLRs, cuticular abrasion, cuticular transpiration, respiratory water loss and metabolic rate for queens of the ant Messor pergandei at three stages: unmated alate queens, newly mated dealate queens (undug foundresses) and mated queens excavated from their incipient nest (dug foundresses); in addition we examined these processes in artificially abraded alate queens. Alate queens had low WLRs and low levels of cuticle abrasion, whereas dug foundresses had high WLRs and high levels of cuticle abrasion. Total WLR and cuticular transpiration were lowest for alate queens, intermediate for undug foundresses and highest for dug foundresses. Respiratory water loss contributed ~10% of the total WLR and was lower for alate queens and undug foundresses than for dug foundresses. Metabolic rate did not vary across stages. Total WLR and cuticular transpiration of artificially abraded alate queens increased, whereas respiratory water loss and metabolic rate were unaffected. Overall, increased cuticular transpiration accounted for essentially all the increased total water loss in undug and dug foundresses and artificially abraded queens. Artificially abraded queens and dug foundresses showed partial recovery after 14 days.

  2. Loss of Power and Water Hammer Event at San Onofre, Unit 1, on November 21, 1985

    International Nuclear Information System (INIS)

    1986-01-01

    On November 21, 1985, Southern California Edison's Onofre Nuclear Generating Station, Unit 1, located south of San Clemente, California, experienced a partial loss of inplant ac electrical power while the plant was operating at 60% power. Following a manual reactor trip, the plant lost all inplant ac power for 4 minutes and experienced a severe incidence of water hammer in the feedwater system which caused a leak, damaged plant equipment, and challenged the integrity of the plant's heat sink. The most significant aspect of the event involved the failure of five safety-related check valves in the feed-water system whose failure occurred in less than year, without detection, and jeopardized the integrity of safety systems. The event involved a number of equipment malfunctions, operator errors, and procedural deficiencies. This report documents the findings and conclusions of an NRC Incident Investigation Team sent to San Onofre by the NRC Executive Director for Operations in conformance with NRC's recently established Incident Investigation Program

  3. Detection of water and its derivatives on individual nanoparticles using vibrational electron energy-loss spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Crozier, Peter A., E-mail: crozier@asu.edu [School for the Engineering of Matter, Transport and Energy, Arizona State University, 501 E. Tyler Mall, Tempe, AZ 85287-6106 (United States); Aoki, Toshihiro [LeRoy Eyring Center for Solid State Science, Arizona State University, Tempe, AZ 85287-1704 (United States); Liu, Qianlang [School for the Engineering of Matter, Transport and Energy, Arizona State University, 501 E. Tyler Mall, Tempe, AZ 85287-6106 (United States)

    2016-10-15

    Understanding the role of water, hydrate and hydroxyl species on nanoparticle surfaces and interfaces is very important in both physical and life sciences. Detecting the presence of oxygen-hydrogen species with nanometer resolution is extremely challenging at present. Here we show that the recently developed vibrational electron energy-loss spectroscopy using subnanometer focused electron beams can be employed to spectroscopically identify the local presence and variation of OH species on nanoscale surfaces. The hydrogen-oxygen fingerprint can be correlated with highly localized structural and morphological information obtained from electron imaging. Moreover, the current approach exploits the aloof beam mode of spectral acquisition which does not require direct electron irradiation of the sample thus greatly reducing beam damage to the OH bond. These findings open the door for using electron microscopy to probe local hydroxyl and hydrate species on nanoscale organic and inorganic structures. - Highlights: • High spatial resolution spectroscopic detection of water related species in nanoparticles. • Detection of OH stretch modes with vibrational EELS. • Differentiation between hydrate and hydroxide species on or on nanoparticles. • Detection of hydrate on a single 60 nm oxide nanoparticle of MgO. • Use of aloof beam EELS to minimize radiation damage.

  4. Assessment of Loss-of-Coolant Effect on Pressurized Heavy Water Reactors

    International Nuclear Information System (INIS)

    Kim, Won Young; Park, Joo Hwan; Kim, Bong Ghi

    2009-01-01

    A CANDU reactor is a heavy-water-moderated, natural uranium fuelled reactor with a pressure tube. The reactor contains a horizontal cylindrical vessel (calandria) and each pressure tube is isolated from the heavy-water moderator in a calandria. This allows the moderator system to be operated of a high-pressure and of a high-temperature coolant in pressure tube. This causes the pressurized liquid coolant in the channel to void and therefore give rise to a reactivity transient in the event of a break or fault in the coolant circuit. In particular, all CANDU reactors are well known to have a positive void reactivity coefficient and thus this phenomenon may lead to a positive feedback, which can cause a large power pulse. We assess the loss-of-coolant effect by coolant void reactivity versus fuel burnup, four factor parameters for fresh fuel and equilibrium fuel, reactivity change due to the change of coolant density and reactivity change in the case of half- and full-core coolant

  5. Thermal-hydraulic analysis of total loss of steam generator feed water in WWER-440

    International Nuclear Information System (INIS)

    Sabotinov, L.; Cadet-Mercier, S.

    2001-01-01

    The analysis is carried out for a WWER-440/V270 with upgraded primary safety valves (replacement of the existing PRZ safety valves with Pilot Operated Relief Valves (PORV) of the type SEBIM (France)) The current analysis is focused on the scenario 'Total Loss of SGs Feed Water' with application of the operator action of primary system 'Feed and Bleed' in order to check the effectiveness of the installed pressurizer SEBIM valves and to verify that the operator can cool down the reactor system and cope with this accident. The calculations have been performed at the Institute of Protection and Nuclear Safety (IPSN) in Fontenay-aux-Roses with the computer code CATHARE 2 Version 1.3L1. CATHARE is a French best estimate thermal-hydraulic program for accident analysis in the light water nuclear reactors, developed with the participation of the IPSN (Institut de Protection et Surete Nucleaire), CEA (Commissariat a l'Energie Atomique), Framatome and EdF (Electricite de France). (author)

  6. Artificial Neural Networks-Based Software for Measuring Heat Collection Rate and Heat Loss Coefficient of Water-in-Glass Evacuated Tube Solar Water Heaters

    Science.gov (United States)

    Liu, Zhijian; Liu, Kejun; Li, Hao; Zhang, Xinyu; Jin, Guangya; Cheng, Kewei

    2015-01-01

    Measurements of heat collection rate and heat loss coefficient are crucial for the evaluation of in service water-in-glass evacuated tube solar water heaters. However, conventional measurement requires expensive detection devices and undergoes a series of complicated procedures. To simplify the measurement and reduce the cost, software based on artificial neural networks for measuring heat collection rate and heat loss coefficient of water-in-glass evacuated tube solar water heaters was developed. Using multilayer feed-forward neural networks with back-propagation algorithm, we developed and tested our program on the basis of 915measuredsamples of water-in-glass evacuated tube solar water heaters. This artificial neural networks-based software program automatically obtained accurate heat collection rateand heat loss coefficient using simply "portable test instruments" acquired parameters, including tube length, number of tubes, tube center distance, heat water mass in tank, collector area, angle between tubes and ground and final temperature. Our results show that this software (on both personal computer and Android platforms) is efficient and convenient to predict the heat collection rate and heat loss coefficient due to it slow root mean square errors in prediction. The software now can be downloaded from http://t.cn/RLPKF08. PMID:26624613

  7. Artificial Neural Networks-Based Software for Measuring Heat Collection Rate and Heat Loss Coefficient of Water-in-Glass Evacuated Tube Solar Water Heaters.

    Science.gov (United States)

    Liu, Zhijian; Liu, Kejun; Li, Hao; Zhang, Xinyu; Jin, Guangya; Cheng, Kewei

    2015-01-01

    Measurements of heat collection rate and heat loss coefficient are crucial for the evaluation of in service water-in-glass evacuated tube solar water heaters. However, conventional measurement requires expensive detection devices and undergoes a series of complicated procedures. To simplify the measurement and reduce the cost, software based on artificial neural networks for measuring heat collection rate and heat loss coefficient of water-in-glass evacuated tube solar water heaters was developed. Using multilayer feed-forward neural networks with back-propagation algorithm, we developed and tested our program on the basis of 915 measured samples of water-in-glass evacuated tube solar water heaters. This artificial neural networks-based software program automatically obtained accurate heat collection rate and heat loss coefficient using simply "portable test instruments" acquired parameters, including tube length, number of tubes, tube center distance, heat water mass in tank, collector area, angle between tubes and ground and final temperature. Our results show that this software (on both personal computer and Android platforms) is efficient and convenient to predict the heat collection rate and heat loss coefficient due to it slow root mean square errors in prediction. The software now can be downloaded from http://t.cn/RLPKF08.

  8. Effect of water losses by evaporation and chemical reaction in an industrial slaker reactor

    Directory of Open Access Journals (Sweden)

    Ricardo Andreola

    2007-03-01

    Full Text Available A dynamic model of the slaker reactor was developed and validated for Klabin Paraná Papéis causticizing system, responsable for white liquor generation used by the plant. The model considered water losses by evaporation and chemical reaction. The model showed a good agreement with the industrial plant measures of active alkali, total titratable alkali and temperature, without the need of adjustment of any parameter. The simulated results showed that the water consumption by the slaking reaction and evaporation exerted significant influence on the volumetric flow rate of limed liquor, which imposed a decrease of 4.6% in the amount of water in reactor outlet.Foi desenvolvido e testado um modelo dinâmico do reator de apagamento do sistema de caustificação da Klabin Paraná Papéis, responsável pela geração do licor branco utilizado na planta. O modelo contempla perdas de água por evaporação e por reação química e apresentou boa concordância com dados industriais de álcali ativo, álcali total titulável e temperatura, sem a necessidade de ajuste de nenhum parâmetro. Os resultados obtidos a partir de simulações revelam que o consumo de água pela reação de apagamento, bem como pela evaporação, exercem uma influência significativa sobre a vazão volumétrica na saída do reator, impondo uma diminuição de 4,6% sobre o teor de água na corrente de saída do reator em relação à alimentação.

  9. Mapping evaporative water loss in desert passerines reveals an expanding threat of lethal dehydration.

    Science.gov (United States)

    Albright, Thomas P; Mutiibwa, Denis; Gerson, Alexander R; Smith, Eric Krabbe; Talbot, William A; O'Neill, Jacqueline J; McKechnie, Andrew E; Wolf, Blair O

    2017-02-28

    Extreme high environmental temperatures produce a variety of consequences for wildlife, including mass die-offs. Heat waves are increasing in frequency, intensity, and extent, and are projected to increase further under climate change. However, the spatial and temporal dynamics of die-off risk are poorly understood. Here, we examine the effects of heat waves on evaporative water loss (EWL) and survival in five desert passerine birds across the southwestern United States using a combination of physiological data, mechanistically informed models, and hourly geospatial temperature data. We ask how rates of EWL vary with temperature across species; how frequently, over what areas, and how rapidly lethal dehydration occurs; how EWL and die-off risk vary with body mass; and how die-off risk is affected by climate warming. We find that smaller-bodied passerines are subject to higher rates of mass-specific EWL than larger-bodied counterparts and thus encounter potentially lethal conditions much more frequently, over shorter daily intervals, and over larger geographic areas. Warming by 4 °C greatly expands the extent, frequency, and intensity of dehydration risk, and introduces new threats for larger passerine birds, particularly those with limited geographic ranges. Our models reveal that increasing air temperatures and heat wave occurrence will potentially have important impacts on the water balance, daily activity, and geographic distribution of arid-zone birds. Impacts may be exacerbated by chronic effects and interactions with other environmental changes. This work underscores the importance of acute risks of high temperatures, particularly for small-bodied species, and suggests conservation of thermal refugia and water sources.

  10. Coherent reflection from surface gravity water waves during reciprocal acoustic transmissions.

    Science.gov (United States)

    Badiey, Mohsen; Song, Aijun; Smith, Kevin B

    2012-10-01

    During a recent experiment in Kauai, Hawaii, reciprocal transmissions were conducted between two acoustic transceivers mounted on the seafloor at a depth of 100 m. The passage of moving surface wave crests was shown to generate focused and intense coherent acoustic returns, which had increasing or decreasing delay depending on the direction of propagation relative to the direction of surface wave crests. It is shown that a rough surface two-dimensional parabolic equation model with an evolving sea surface can produce qualitative agreement with data for the dynamic surface returns.

  11. Transmission of tularemia from a water source by transstadial maintenance in a mosquito vector

    Science.gov (United States)

    Bäckman, Stina; Näslund, Jonas; Forsman, Mats; Thelaus, Johanna

    2015-01-01

    Mosquitoes are thought to function as mechanical vectors of Francisella tularensis subspecies holarctica (F. t. holarctica) causing tularemia in humans. We investigated the clinical relevance of transstadially maintained F. t. holarctica in mosquitoes. Aedes egypti larvae exposed to a fully virulent F. t. holarctica strain for 24 hours, were allowed to develop into adults when they were individually homogenized. Approximately 24% of the homogenates tested positive for F. t. DNA in PCR. Mice injected with the mosquito homogenates acquired tularemia within 5 days. This novel finding demonstrates the possibility of transmission of bacteria by adult mosquitoes having acquired the pathogen from their aquatic larval habitats.

  12. Influence of soil water repellency on runoff and solute loss from New Zealand pasture

    Science.gov (United States)

    Jeyakumar, P.; Müller, K.; Deurer, M.; van den Dijssel, C.; Mason, K.; Green, S.; Clothier, B. E.

    2012-04-01

    Soil water repellency (SWR) has been reported in New Zealand, but knowledge on its importance for the country's economy and environment is limited. Our recent survey on the occurrence of SWR under pasture across the North Island of New Zealand showed that most soils exhibited SWR when dry independent of climate but influenced by the soil order. SWR is discussed as an important soil surface condition enhancing run-off and the transfer of fertilizers and pesticides from agricultural land into waterways. So far, the impact of SWR on run-off has rarely been measured. We developed a laboratory-scale run-off measurement apparatus (ROMA) to quantify directly the impact of SWR on run-off from undisturbed soil slabs. We compared the run-off resulting from the run-on of water with that resulting from an ethanol (30% v/v) solution, which is a fully-wetting liquid even in severely hydrophobic soils. Thus, the experiments with the ethanol solution can be understood as a proxy measure of the wetting-up behaviour of hydrophilic soils. We conducted ROMA run-off experiments with air-dried soil slabs (460 mm long x 190 mm wide x 50 mm deep) collected from pastoral sites, representing three major soil orders in the North Island: Recent Soil (Fluvisol), Gley Soil (Gleysol), and Organic Soil (Histosol), with water followed by the ethanol solution at a run-on rate of 60 mm/h. Bromide was applied at 80 kg KBr/ha prior to the water experiments to assess potential solute losses via run-off. The air-dried soils had a high degree and persistence of SWR (contact angles, 97, 98 and 104° , and potential water drop penetration times, 42, 54 and 231 min for the Fluvisol, Gleysol and Histosol, respectively). Under identical soil and experimental conditions, water generated run-off from all soils, but in the experiments with the ethanol solution, the entire ethanol solution infiltrated into the soils. The ranking of the run-off coefficients of the soils directly reflected their ranking in

  13. Can water disinfection prevent the transmission of infectious koi herpesvirus to naïve carp? - a case report.

    Science.gov (United States)

    Bergmann, S M; Monro, E S; Kempter, J

    2017-07-01

    Hygienic measures such as disinfection are important tools for the maintenance of fish health in aquaculture. While little information is available on the disinfection of water intended for fish containment, Huwa-San ® , a disinfectant used in food and water industries, was used for daily treatment at concentrations of approximately 60 ppm over a total period of 3 months (experiment 1) with a 3-week treatment-free interval after 2 months (experiment 2). During this period, koi herpesvirus (KHV) was added to the water of two aquaria, one used as a normal contact control, the other one receiving daily water disinfectant treatments that prevented KHV infection of carp. In the second experiment, Huwa-San ® treatment was interrupted and KHV infection was prevalent. However, when naïve fish were introduced to the same aquarium after re-application of disinfectant, KHV could not be detected in those naïve fish. Whilst KHV could not be detected in samples where disinfectant had been applied, it was present in samples of naïve fish cohabiting with infection contact control animals which had undergone no disinfectant treatment over experiments 1 and 2. The results presented here show that water treatment with a disinfectant may prevent transmission of infectious KHV to naïve carp cohabited with infected carp. © 2016 John Wiley & Sons Ltd.

  14. Predictors of loss to follow-up among children registered in an HIV prevention mother-to-child transmission cohort study in Pernambuco, Brazil.

    Science.gov (United States)

    Gouveia, Pedro Alves da Cruz; da Silva, Gerlane Alves Pontes; de Albuquerque, Maria de Fatima Pessoa Militão

    2014-11-27

    Mother-to-child transmission of HIV (MTCT) is the major form of acquiring the disease among children. The loss to follow-up (LTF) of mothers and their children is a problem that affects the effectiveness of programs for the prevention of mother-to-child transmission (PMTCT). The aim of this study is to identify risk factors associated with the LTF of HIV-exposed children in the state of Pernambuco, Brazil. A retrospective cohort study was carried out with 1200 HIV-exposed children born between 2000 and 2009, registered up to the age of 2 months in a public health PMTCT program. Children were considered LTF if they did not return for scheduled visits to monitor infection status. Univariate and multivariate logistic regression analyses were conducted to identify risk factors for LTF. A total of 185 children (15.4%; CI: 95%: 13.4-17.4%) met the case definition of LTF before the determination of serological HIV status. Risk factors independently associated with LTF were mother-child pairs who reside in rural and remote areas (OR 1.86; 95% CI: 1.30-2.66) and mothers who use illicit drugs (OR 1.8; 95% CI: 1.08-3.0). Initiation of the PMTCT during pregnancy was a protective factor for LTF (OR 0.69; 95% CI: 0.49-0.96). The decentralization of support services for HIV-exposed children to other cities in the state seems to be crucial for the accurate monitoring of outcomes. It is also important to introduce additional measures addressing mothers who are drug users so that they remain in the program: an intensive follow-up program that actively searches for absentee mother-child pairs, support from social services and treatment for drug-dependency. The findings of this study highlight the importance of diagnosing mothers as early as possible in order to conduct a more complete follow-up period of the children. Solving the above-mentioned problems is a challenge, which must be overcome so as to improve the quality of PMTCT.

  15. Simulating water and nitrogen loss from an irrigated paddy field under continuously flooded condition with Hydrus-1D model.

    Science.gov (United States)

    Yang, Rui; Tong, Juxiu; Hu, Bill X; Li, Jiayun; Wei, Wenshuo

    2017-06-01

    Agricultural non-point source pollution is a major factor in surface water and groundwater pollution, especially for nitrogen (N) pollution. In this paper, an experiment was conducted in a direct-seeded paddy field under traditional continuously flooded irrigation (CFI). The water movement and N transport and transformation were simulated via the Hydrus-1D model, and the model was calibrated using field measurements. The model had a total water balance error of 0.236 cm and a relative error (error/input total water) of 0.23%. For the solute transport model, the N balance error and relative error (error/input total N) were 0.36 kg ha -1 and 0.40%, respectively. The study results indicate that the plow pan plays a crucial role in vertical water movement in paddy fields. Water flow was mainly lost through surface runoff and underground drainage, with proportions to total input water of 32.33 and 42.58%, respectively. The water productivity in the study was 0.36 kg m -3 . The simulated N concentration results revealed that ammonia was the main form in rice uptake (95% of total N uptake), and its concentration was much larger than for nitrate under CFI. Denitrification and volatilization were the main losses, with proportions to total consumption of 23.18 and 14.49%, respectively. Leaching (10.28%) and surface runoff loss (2.05%) were the main losses of N pushed out of the system by water. Hydrus-1D simulation was an effective method to predict water flow and N concentrations in the three different forms. The study provides results that could be used to guide water and fertilization management and field results for numerical studies of water flow and N transport and transformation in the future.

  16. Reduced water vapor transmission rates of low-temperature solution-processed metal oxide barrier films via ultraviolet annealing

    Energy Technology Data Exchange (ETDEWEB)

    Park, Seonuk; Jeong, Yong Jin; Baek, Yonghwa; Kim, Lae Ho; Jang, Jin Hyuk; Kim, Yebyeol [POSTECH Organic Electronics Laboratory, Polymer Research Institute, Department of Chemical Engineering, Pohang University of Science and Technology, Pohang, 790-784 (Korea, Republic of); An, Tae Kyu [Department of Polymer Science & Engineering, Korea National University of Transportation, 50 Daehak-Ro, Chungju (Korea, Republic of); Nam, Sooji, E-mail: sjnam15@etri.re.kr [Information Control Device Section, Electronics and Telecommunications Research Institute, Daejeon, 305-700 (Korea, Republic of); Kim, Se Hyun, E-mail: shkim97@yu.ac.kr [School of Chemical Engineering, Yeungnam University, Gyeongsan, North Gyeongsang 712-749 (Korea, Republic of); Jang, Jaeyoung, E-mail: jyjang15@hanyang.ac.kr [Department of Energy Engineering, Hanyang University, Seoul, 133-791 (Korea, Republic of); Park, Chan Eon, E-mail: cep@postech.ac.kr [POSTECH Organic Electronics Laboratory, Polymer Research Institute, Department of Chemical Engineering, Pohang University of Science and Technology, Pohang, 790-784 (Korea, Republic of)

    2017-08-31

    Highlights: • Sol-gel-derived aluminum oxide thin films were prepared using ultraviolet (UV) annealing. • UV irradiation dramatically promoted the densification of AlO{sub x} during the annealing stage, thereby forming a close-packed AlO{sub x} film. • The resulting AlO{sub x} films deposited on polymer substrates exhibited good water vapor blocking properties with low water vapor transmission rates (WVTRs). - Abstract: Here, we report the fabrication of low-temperature sol-gel-derived aluminum oxide (AlO{sub x}) films via ultraviolet (UV) annealing and the investigation of their water vapor blocking properties by measuring the water vapor transmission rates (WVTRs). The UV annealing process induced the formation of a dense metal-oxygen-metal bond (Al-O-Al structure) at low temperatures (<200 °C) that are compatible with commercial plastic substrates. The density of the UV-annealed AlO{sub x} thin film at 180 °C was comparable to that of AlO{sub x} thin films that have been thermally annealed at 350 °C. Furthermore, the UV-annealed AlO{sub x} thin films exhibited a high optical transparency in the visible region (>99%) and good electrical insulating properties (∼10{sup −7} A/cm{sup 2} at 2 MV/cm). Finally, we confirmed that a dense AlO{sub x} thin film was successfully deposited onto the plastic substrate via UV annealing at low temperatures, leading to a substantial reduction in the WVTRs. The Ca corrosion test was used to measure the WVTRs of AlO{sub x} thin films deposited onto polyethylene naphthalate or polyimide substrates, determined to be 0.0095 g m{sup −2} day{sup −1} (25 °C, 50% relative humidity) and 0.26 g m{sup −2} day{sup −1}, respectively.

  17. Making C4 crops more water efficient under current and future climate: Tradeoffs between carbon gain and water loss

    Science.gov (United States)

    Srinivasan, V.; Pignon, C.

    2017-12-01

    C4 plants have a carbon concentrating mechanism that has evolved under historically low CO2 concentrations of around 200 ppm. However, increases in global CO2 concentrations in recent times (current CO2 concentrations are at 400 ppm and it is projected to be 550 ppm by mid-century) have diminished the relative advantage of C4 plants over C3 plants, which lack the expensive carbon concentrating machinery. Here we show by employing model simulations that under pre-historic CO2 concentrations, C4 plants are near optimal in their stomatal behavior and nitrogen partitioning between carbon concentrating machinery and carboxylation machinery, and they are significantly supra-optimal under current and future elevated CO2 concentrations. Model simulations performed at current CO2 concentrations of 400 ppm show that, under high light conditions, decreasing stomatal conductance by 20% results in a 15% increase in water use efficiency with negligible loss in photosynthesis. Under future elevated CO2 concentrations of 550 ppm, a 40% decrease in stomatal conductance produces a 35% increase in water use efficiency. Furthermore, stomatal closure is shown to be more effective in decreasing whole canopy transpiration compared to canopy top leaf transpiration, since shaded leaves are more supra-optimal than sunlit leaves. Model simulations for optimizing nitrogen distribution in C4 leaves show that under high light conditions, C4 plants over invest in carbon concentrating machinery and under invest in carboxylation machinery. A 20% redistribution in leaf nitrogen results in a 10% increase in leaf carbon assimilation without significant increases in transpiration under current CO2 concentrations of 400 ppm. Similarly, a 40% redistribution in leaf nitrogen results in a 15% increase in leaf carbon assimilation without significant increases in transpiration under future elevated CO2 concentrations of 550 ppm. Our model optimality simulations show that C4 leaves a supra optimal in their

  18. Viability study of photodiodes utilization in determination of soil water content by gamma transmission

    International Nuclear Information System (INIS)

    Santos, L.A.P.; Khoury, H.; Carneiro, C.J.G.

    1991-01-01

    An experiment to verify the viability of using silicon photodetectors in a sup(241)Am γ-ray spectroscopy system for measuring soil water content was carried out in disturbed soil cores. The good correlation between the logarithm of the attenuation factor and the water content, r sup(2)=0.99, proves that the low efficiency of these detectors is not a limiting factor in measuring the water content. Furthermore, the small dimensions of the silicon photodetectors and associate electronic equipment are important characteristics that could permit the construction of a portable gammametry system to be used under field conditions. (author)

  19. Floating microbial fuel cells as energy harvesters for signal transmission from natural water bodies

    Science.gov (United States)

    Schievano, Andrea; Colombo, Alessandra; Grattieri, Matteo; Trasatti, Stefano P.; Liberale, Alessandro; Tremolada, Paolo; Pino, Claudio; Cristiani, Pierangela

    2017-02-01

    A new type of floating microbial fuel cell (fMFC) was developed for power supply of remote environmental sensors and data transmission. Ten operating fMFCs generated a cell potential in the range 100-800 mV depending on the external resistance applied. Power production peaked around 3-3.5 mW (power density of 22-28 mW m-2 cathode) after about 20-30 days of start-up period. The average of daily electrical energy harvested ranged between 10 and 35 mWh/d. Long-term performances were ensured in the presence of dense rice plants (Oryza Sativa). A power management system, based on a step-up DC/DC converter and a low-power data transmission system via SIGFOX™ technology, have been set up for the fMFCs. The tested fMFCs systems allowed to: i) harvest produced energy, ii) supply electronic devices (intermittent LED-light and a buzzer); iii) transmit remote data at low speed (three message of 12 bites each, in 6 s). Several 'floating garden' MFCs were set in the context of demonstrative events at EXPO2015 world exposition held in Milan between May-October 2015. Some of the 'floating garden' MFCs were operating for more than one year.

  20. Rates of Water Loss and Uptake in Recalcitrant Fruits of Quercus Species Are Determined by Pericarp Anatomy

    Science.gov (United States)

    Xia, Ke; Daws, Matthew I.; Stuppy, Wolfgang; Zhou, Zhe-Kun; Pritchard, Hugh W.

    2012-01-01

    Desiccation-sensitive recalcitrant seeds and fruits are killed by the loss of even moderate quantities of water. Consequently, minimizing the rate of water loss may be an important ecological factor and evolutionary driver by reducing the risk of mortality during post-dispersal dry-spells. For recalcitrant fruits of a range of Quercus species, prolonged drying times have been observed previously. However, the underlying mechanism(s) for this variation is unknown. Using nine Quercus species we investigated the major route(s) of water flow into and out of the fruits and analysed the relative importance of the different pericarp components and their anatomy on water uptake/loss. During imbibition (rehydration), the surface area of the cupule scar and the frequency and area of the vascular bundles contained therein were significantly correlated with the rates of water uptake across the scar. The vascular bundles serving the apex of the fruit were a minor contributor to overall water. Further, the rate of water uptake across the remainder of the pericarp surface was significantly correlated with the thickness of the vascularised inner layer in the pericarp. Fruits of Q. franchetii and Q. schottkyana dried most slowly and had a comparatively small scar surface area with few vascular bundles per unit area. These species inhabit drier regions than the other species studied, suggesting these anatomical features may have ecological value by reducing the risk of desiccation stress. However, this remains to be tested in the field. PMID:23071795

  1. Increased malaria transmission around irrigation schemes in Ethiopia and the potential of canal water management for malaria vector control.

    Science.gov (United States)

    Kibret, Solomon; Wilson, G Glenn; Tekie, Habte; Petros, Beyene

    2014-09-13

    releases. Similarly, there was a strong positive correlation between bi-weekly vector density and canal water releases lagged by two weeks. Furthermore, monthly malaria incidence was strongly correlated with monthly vector density lagged by a month in the irrigated villages. The present study revealed that the irrigation schemes resulted in intensified malaria transmission due to poor canal water management. Proper canal water management could reduce vector abundance and malaria transmission in the irrigated villages.

  2. Water sources and controls on water-loss rates of epigeous ectomycorrhizal fungal sporocarps during summer drought

    Science.gov (United States)

    Erik A. Lilleskov; Thomas D. Bruns; Todd E. Dawson; Francisco J. Camacho

    2009-01-01

    Access to deeper soil water and water-conserving traits should reduce water stress for ectomycorrhizal fungi, permitting function during drought. Here, we explored whether epigeous fruiting of ectomycorrhizal fungi during drought was facilitated by access to deep soil water, how much water was lost from sporocarps, and how sporocarp surface to volume ratios affected...

  3. ITER SAFETY TASK NID-5D: Operational tritium loss and accident investigation for heat transport and water detritiation systems

    International Nuclear Information System (INIS)

    Kalyanam, K.M.; Fong, C.; Moledina, M.; Natalizio, A.

    1995-02-01

    The task objectives are to: a) determine major pathways for tritium loss during normal operation of the cooling systems and water detritiation system, b) estimate operational losses and environmental tritium releases from the heat transport and water detritiation systems of ITER, and c) prepare a preliminary Failure Modes and Effects Analysis (FMEA) for the ITER Water Detritiation System. The analysis will be used to estimate chronic environmental tritium releases (airborne and waterborne) for the ITER Cooling Systems and Water Detritiation System. The assessment will form the basis for demonstrating the acceptability of ITER for siting in the Early Safety and Environmental Characterization Study (ESECS), to be issued in early 1995. (author). 7 refs., 10 tabs., 11 figs

  4. Development of skin structure and cutaneous water loss in nestling desert house sparrows from Saudi Arabia.

    Science.gov (United States)

    Groff, Brandon; Muñoz-Garcia, Agustí; Yamaguchi, Mamoru; Williams, Joseph B

    2007-06-01

    The outer layer of the epidermis, the stratum corneum (SC), contains lipids and corneocytes, which together form layers that limit cutaneous water loss (CWL). We examined the development of structure of the SC and CWL in nestling House Sparrows (Passer domesticus) from Saudi Arabia. We measured CWL of nestlings, and characterized development of their epidermis using electron microscopy. We tested two antagonistic hypotheses, that CWL decreases as nestlings age, a response to increased thickness of SC, and an opposite idea that CWL increases as nestlings age even though the number of layers of the SC remains constant. CWL of nestling House Sparrows varied with developmental stages, in a non-linear fashion, but not significantly so. CWL of nestlings averaged 7.31+/-1.5 g H(2)O/(m(2) h), whereas for adults it was 4.95 g/(m(2) h); adult CWL was 67.7% that of nestlings. We found that morphology of the SC did not change linearly with age, but seemed to vary with developmental stage. CWL decreased as the SC thickness increased and as the total thickness of the corneocytes increased. Further, we found that CWL decreased as the thickness of the extracellular space increased, number of corneocytes increased, and proportion of the SC that is extracellular space increased.

  5. Total loss of CNA1 steam generators feed water simulated with RELAP5/MOD3

    International Nuclear Information System (INIS)

    Marino, Edgardo J.L.

    2000-01-01

    The results of the calculations are presented carried out by utilizing the code RELAP5/MOD3, upon the basis of the postulated initial event of total loss of feed water to the two steam generators in the nuclear power plant Atucha 1, CNA1. The evolution of the installation systems during the transient was analyzed in different conditions of availability: condenser, relief valve and safety valves in the secondary system, safety valves in the primary system and system of long-term subsequent cooling. Located in the primary and secondary systems of the installation they turn out to be prominent in this event. Upon this basis the sequences of possible evolution were calculated and those that would conduct the system toward the setting called 'damage to the core' were determined. Also those in which would arrive to a state of 'safe shutdown' were determined. These results were utilized in the verification of the tree of events utilized in the Final Report of the Probabilistic Safety Analysis for the sequence of event T9, made from calculations carried out with the code DINETZ. From this compare some differences were determined and are presented in the modified version of tree of events. (author)

  6. Lipid composition of the stratum corneum and cutaneous water loss in birds along an aridity gradient.

    Science.gov (United States)

    Champagne, Alex M; Muñoz-Garcia, Agustí; Shtayyeh, Tamer; Tieleman, B Irene; Hegemann, Arne; Clement, Michelle E; Williams, Joseph B

    2012-12-15

    Intercellular and covalently bound lipids within the stratum corneum (SC), the outermost layer of the epidermis, are the primary barrier to cutaneous water loss (CWL) in birds. We compared CWL and intercellular SC lipid composition in 20 species of birds from desert and mesic environments. Furthermore, we compared covalently bound lipids with CWL and intercellular lipids in the lark family (Alaudidae). We found that CWL increases in birds from more mesic environments, and this increase was related to changes in intercellular SC lipid composition. The most consistent pattern that emerged was a decrease in the relative amount of cerebrosides as CWL increased, a pattern that is counterintuitive based on studies of mammals with Gaucher disease. Although covalently bound lipids in larks did not correlate with CWL, we found that covalently bound cerebrosides correlated positively with intercellular cerebrosides and intercellular cholesterol ester, and intercellular cerebrosides correlated positively with covalently bound free fatty acids. Our results led us to propose a new model for the organization of lipids in the avian SC, in which the sugar moieties of cerebrosides lie outside of intercellular lipid layers, where they may interdigitate with adjacent intercellular cerebrosides or with covalently bound cerebrosides.

  7. Adaptation of metabolism and evaporative water loss along an aridity gradient.

    Science.gov (United States)

    Tieleman, B Irene; Williams, Joseph B; Bloomer, Paulette

    2003-01-22

    Broad-scale comparisons of birds indicate the possibility of adaptive modification of basal metabolic rate (BMR) and total evaporative water loss (TEWL) in species from desert environments, but these might be confounded by phylogeny or phenotypic plasticity. This study relates variation in avian BMR and TEWL to a continuously varying measure of environment, aridity. We test the hypotheses that BMR and TEWL are reduced along an aridity gradient within the lark family (Alaudidae), and investigate the role of phylogenetic inertia. For 12 species of lark, BMR and TEWL decreased along a gradient of increasing aridity, a finding consistent with our proposals. We constructed a phylogeny for 22 species of lark based on sequences of two mitochondrial genes, and investigated whether phylogenetic affinity played a part in the correlation of phenotype and environment. A test for serial independence of the data for mass-corrected TEWL and aridity showed no influence of phylogeny on our findings. However, we did discover a significant phylogenetic effect in mass-corrected data for BMR, a result attributable to common phylogenetic history or to common ecological factors. A test of the relationship between BMR and aridity using phylogenetic independent constrasts was consistent with our previous analysis: BMR decreased with increasing aridity.

  8. White-nose syndrome increases torpid metabolic rate and evaporative water loss in hibernating bats.

    Science.gov (United States)

    McGuire, Liam P; Mayberry, Heather W; Willis, Craig K R

    2017-12-01

    Fungal diseases of wildlife typically manifest as superficial skin infections but can have devastating consequences for host physiology and survival. White-nose syndrome (WNS) is a fungal skin disease that has killed millions of hibernating bats in North America since 2007. Infection with the fungus Pseudogymnoascus destructans causes bats to rewarm too often during hibernation, but the cause of increased arousal rates remains unknown. On the basis of data from studies of captive and free-living bats, two mechanistic models have been proposed to explain disease processes in WNS. Key predictions of both models are that WNS-affected bats will show 1 ) higher metabolic rates during torpor (TMR) and 2 ) higher rates of evaporative water loss (EWL). We collected bats from a WNS-negative hibernaculum, inoculated one group with P. destructans , and sham-inoculated a second group as controls. After 4 mo of hibernation, TMR and EWL were measured using respirometry. Both predictions were supported, and our data suggest that infected bats were more affected by variation in ambient humidity than controls. Furthermore, disease severity, as indicated by the area of the wing with UV fluorescence, was positively correlated with EWL, but not TMR. Our results provide the first direct evidence that heightened energy expenditure during torpor and higher EWL independently contribute to WNS pathophysiology, with implications for the design of potential treatments for the disease. Copyright © 2017 the American Physiological Society.

  9. Interfacing systems LOCAs [Loss of Coolant Accidents] at boiling water reactors

    International Nuclear Information System (INIS)

    Chu, Tsong-Lun; Fitzpatrick, R.; Stoyanov, S.

    1987-01-01

    The work presented in this paper was performed by Brookhaven National Laboratory (BNL) in support of Nuclear Regulatory Commission's (NRC) effort towards the resolution of Generic Issue 105 ''Interfacing System Loss of Coolant Accidents (LOCAs) at Boiling Water Reactors (BWRs).'' For BWRs, intersystem LOCA have typically either not been considered in probabilistic risk analyses, or if considered, were judged to contribute little to the risk estimates because of their perceived low frequency of occurrence. However, recent operating experience indicates that the pressure isolation valves (PIVs) in BWRs may not adequately protect against overpressurization of low pressure systems. The objective of this paper is to present the results of a study which analyzed interfacing system LOCA at several BWRs. The BWRs were selected to best represent a spectrum of BWRs in service using industry operating event experience and plant-specific information/configurations. The results presented here include some possible changes in test requirements/practices as well as an evaluation of their reduction potential in terms of core damage frequency

  10. Analysis of LOAF(Loss of All Feed Water) Accident using OPR1000 Simulator

    International Nuclear Information System (INIS)

    Hwang, Do Hyun; Lee, Myeong Soo; Hong, Jin Hyuk; Byon, Su Jin

    2011-01-01

    Recently, a ferocious tsunami unleashed by Japan's biggest recorded earthquake slammed into its eastern coast, killing hundreds of people as it carried away ships, cars and homes, and triggered widespread fires that burned out of control. In the meantime, it damaged Fukushima nuclear power plants and it seems that radiation containing hydrochloric acid, potassium cyanide and other harmful chemicals has been released. People are concerned even if residual radiation levels are not high because Korea might be vulnerable to the spread of radiation from Japan. In this paper, LOAF(Loss Of All Feed Water) accident will be covered to provide information on cause and effect of measures against LOAF accident using OPR1000 simulator, which is using for training operators of ShinKori-Unit 1 and 2 and ShinWolsung-Unit 1 and 2. OPR1000 simulator adopted RELAP5 R/T code for the modeling of NSSS (Nuclear Steam Supply System) TH (Thermal-Hydraulics) and Reactor Core, and selected 3KEYMASTERTM, a commercial plant simulation tool for NSSS auxiliary systems modeling, BOP(Balance of Plant) modeling and simulator environment

  11. Water Table Management Reduces Tile Nitrate Loss in Continuous Corn and in a Soybean-Corn Rotation

    Directory of Open Access Journals (Sweden)

    Craig F. Drury

    2001-01-01

    Full Text Available Water table management systems can be designed to alleviate soil water excesses and deficits, as well as reduce nitrate leaching losses in tile discharge. With this in mind, a standard tile drainage (DR system was compared over 8 years (1991 to 1999 to a controlled tile drainage/subirrigation (CDS system on a low-slope (0.05 to 0.1% Brookston clay loam soil (Typic Argiaquoll in southwestern Ontario, Canada. In the CDS system, tile discharge was controlled to prevent excessive drainage, and water was pumped back up the tile lines (subirrigation to replenish the crop root zone during water deficit periods. In the first phase of the study (1991 to 1994, continuous corn (Zea mays, L. was grown with annual nitrogen (N fertilizer inputs as per local soil test recommendations. In the second phase (1995 to 1999, a soybean (Glycine max L., Merr.-corn rotation was used with N fertilizer added only during the two corn years. In Phase 1 when continuous corn was grown, CDS reduced total tile discharge by 26% and total nitrate loss in tile discharge by 55%, compared to DR. In addition, the 4-year flow weighted mean (FWM nitrate concentration in tile discharge exceeded the Canadian drinking water guideline (10 mg N l–1 under DR (11.4 mg N l–1, but not under CDS (7.0 mg N l–1. In Phase 2 during the soybean-corn rotation, CDS reduced total tile discharge by 38% and total nitrate loss in tile discharge by 66%, relative to DR. The 4-year FWM nitrate concentration during Phase 2 in tile discharge was below the drinking water guideline for both DR (7.3 mg N l–1 and CDS (4.0 mg N l–1. During both phases of the experiment, the CDS treatment caused only minor increases in nitrate loss in surface runoff relative to DR. Hence CDS decreased FWM nitrate concentrations, total drainage water loss, and total nitrate loss in tile discharge relative to DR. In addition, soybean-corn rotation reduced FWM nitrate concentrations and total nitrate loss in tile discharge

  12. Seasonal and regional dynamics of M. ulcerans transmission in environmental context: deciphering the role of water bugs as hosts and vectors.

    Science.gov (United States)

    Marion, Estelle; Eyangoh, Sara; Yeramian, Edouard; Doannio, Julien; Landier, Jordi; Aubry, Jacques; Fontanet, Arnaud; Rogier, Christophe; Cassisa, Viviane; Cottin, Jane; Marot, Agnès; Eveillard, Matthieu; Kamdem, Yannick; Legras, Pierre; Deshayes, Caroline; Saint-André, Jean-Paul; Marsollier, Laurent

    2010-07-06

    Buruli ulcer, the third mycobacterial disease after tuberculosis and leprosy, is caused by the environmental mycobacterium M. ulcerans. Various modes of transmission have been suspected for this disease, with no general consensus acceptance for any of them up to now. Since laboratory models demonstrated the ability of water bugs to transmit M. ulcerans, a particular attention is focused on the transmission of the bacilli by water bugs as hosts and vectors. However, it is only through detailed knowledge of the biodiversity and ecology of water bugs that the importance of this mode of transmission can be fully assessed. It is the objective of the work here to decipher the role of water bugs in M. ulcerans ecology and transmission, based on large-scale field studies. The distribution of M. ulcerans-hosting water bugs was monitored on previously unprecedented time and space scales: a total of 7,407 water bugs, belonging to large number of different families, were collected over one year, in Buruli ulcer endemic and non endemic areas in central Cameroon. This study demonstrated the presence of M. ulcerans in insect saliva. In addition, the field results provided a full picture of the ecology of transmission in terms of biodiversity and detailed specification of seasonal and regional dynamics, with large temporal heterogeneity in the insect tissue colonization rate and detection of M. ulcerans only in water bug tissues collected in Buruli ulcer endemic areas. The large-scale detection of bacilli in saliva of biting water bugs gives enhanced weight to their role in M. ulcerans transmission. On practical grounds, beyond the ecological interest, the results concerning seasonal and regional dynamics can provide an efficient tool in the hands of sanitary authorities to monitor environmental risks associated with Buruli ulcer.

  13. Transmission gamma ray study in horizon transition interface in soil, during infiltration and water redistribution process

    International Nuclear Information System (INIS)

    Appoloni, C.R.; Saito, H.; Algozini Junior, A.

    1992-01-01

    The horizontal erosion process in soil internal layers, in which exists a interface between different horizons or a high degree compaction region, can be emphasized through an alteration on hydraulic conductivity and diffusivity functions. With this objective, we measured the vertical infiltration and the water redistribution, in soil sample 'latossolo vermelho escuro - fase argilosa'. (author)

  14. Secondary transmission of cryptosporidiosis associated with well water consumption: two case studies.

    Science.gov (United States)

    Rezende, Natania Carol Cavalcante; Bezerra, Camila Loredana Pereira Alves Madeira; Almeida, Jéssica Jacinto Salviano de; Fernandes, Tatiane Uetti Gomes; Luz, Kleber Giovanni

    2016-04-01

    Cryptosporidiosis is a very prominent disease in the field of public health, and usually causes diarrhea. We describe two immunocompetent patients who presented with chronic diarrhea that was ultimately found to be caused by continuous exposure to well water contaminated with the microbial cysts (oocysts) of the Cryptosporidium spp parasite. We describe the patients' histories and possible explanations for their prolonged symptoms.

  15. Water flow in bedrock; estimation of influence of transmissive shaft and borehole

    International Nuclear Information System (INIS)

    Andersson, L.; Neretnieks, J.; Rasmuson, A.

    1983-01-01

    The bedrock, a system of large and small fractures that permit water transport through the rock mass. The water content of the bedrock can, under varying hydrostatic pressure conditions, give rise to different flow patterns via boreholes or shafts drilled through the rock. A case is dealt with where a borehole connects a low point in the terrain with a point in the repository where the hydrostatic pressure is higher than at the mouth of the borehole. The situation may be conceived as having arisen when the area was investigated and a hole was drilled at an angle down from the valley to a point below the high point in the area. If the borehole is not sealed, an artesian well may be created. The conductivity used, 2 times 10- 9 m/s, presumes that the repository has been emplaced in average quality rock at this depth. In reality, the repository site will be selected where the rock is better than average. In reality, a shaft - even if it is imperfectly backfilled - or a borehole exerts a flow resistance that reduces the available pressure difference at a depth of 500 m. Taken together, these factors indicate that approx. 5 m 3 /(year, 5 m) is the water flow that can be expected to emerge from the repository through a shaft or a borehole. Only this flow can have been contaminated with escaping substances from the repository area. Water that flows in from other parts of the hole dilutes this flow considerably. (G.B.)

  16. Hydrological Components of a Young Loblolly Pine Plantation on a Sandy Soil with Estimates of Water Use and Loss

    Science.gov (United States)

    Deborah A. Abrahamson; Phillip M. Dougherty; Stanley J. Zarnoch

    1998-01-01

    Fertilizer and irrigation treatments were applied in a 7- to l0-year-old loblolly pine (Pinus taeda L.) plantation on a sandy soil near Laurinburg, North Carolina. Rainfall, throughfall, stemflow, and soil water content were measured throughout the study period. Monthly interception losses ranged from 4 to 15% of rainfall. Stemflow ranged from 0.2...

  17. CNE (Embalse nuclear power plant): probabilistic safety study. Loss of service water. Probabilistic evaluation and analysis through events sequence

    International Nuclear Information System (INIS)

    Couto, A.J.; Perez, S.S.

    1987-01-01

    This work is part of a study on the service water systems of the Embalse nuclear power plant from a safety point of view. The faults of service water systems of high and low pressure that can lead to situations threatening the plant safety were analyzed in a previous report. The event 'total loss of low pressure service water' causes the largest number of such conditions. Such event is an operational incident that can lead to an accident situation due to faults in the required process systems or by omission of a procedure. The annual frequency of the event 'total loss of low pressure service water' is calculated. The main contribution comes from pump failure. The evaluation of the accident sequences shows that the most direct way to the liberation of fission products is the loss of steam generators as heat sink. The contributions to small and large LOCA and electric supply loss are analyzed. The sequence that leads to tritium release through boiling of moderator is also evaluated. (Author)

  18. Assessment of the intrinsic vulnerability of agricultural land to water and nitrogen losses: case studies in Italy and Greece

    Science.gov (United States)

    Aschonitis, V. G.; Mastrocicco, M.; Colombani, N.; Salemi, E.; Castaldelli, G.

    2014-09-01

    LOS indices (abbr. of Losses) can be used for the assessment of the intrinsic vulnerability of agricultural land to water and nitrogen losses through percolation and runoff. The indices were applied on the lowland region of Ferrara Province (FP) in Italy and the upland region of Sarigkiol Basin (SB) in Greece. The most vulnerable zones in FP were the coastal areas consisting of high permeability sandy dunes and the areas close to riverbanks and palaeochannels, and in SB were the areas characterized by high slopes and high permeability soils at high altitude and areas belonging to the upper part of the alluvial plain close to the boundaries between agricultural land and mountainous regions. The application of LOS indices highlighted the specific features of both lowland and upland regions that contribute to water and nitrogen losses and showed their ability for use as tools in designing environmental management plans.

  19. Impacts of soil conditioners and water table management on phosphorus loss in tile drainage from a clay loam soil.

    Science.gov (United States)

    Zhang, T Q; Tan, C S; Zheng, Z M; Welacky, T W; Reynolds, W D

    2015-03-01

    Adoption of waste-derived soil conditioners and refined water management can improve soil physical quality and crop productivity of fine-textured soils. However, the impacts of these practices on water quality must be assessed to ensure environmental sustainability. We conducted a study to determine phosphorus (P) loss in tile drainage as affected by two types of soil conditioners (yard waste compost and swine manure compost) and water table management (free drainage and controlled drainage with subirrigation) in a clay loam soil under corn-soybean rotation in a 4-yr period from 1999 to 2003. Tile drainage flows were monitored and sampled on a year-round continuous basis using on-site auto-sampling systems. Water samples were analyzed for dissolved reactive P (DRP), particulate P (PP), and total P (TP). Substantially greater concentrations and losses of DRP, PP, and TP occurred with swine manure compost than with control and yard waste compost regardless of water table management. Compared with free drainage, controlled drainage with subirrigation was an effective way to reduce annual and cumulative losses of DRP, PP, and TP in tile drainage through reductions in flow volume and P concentration with control and yard waste compost but not with swine manure compost. Both DRP and TP concentrations in tile drainage were well above the water quality guideline for P, affirming that subsurface loss of P from fine-textured soils can be one critical source for freshwater eutrophication. Swine manure compost applied as a soil conditioner must be optimized by taking water quality impacts into consideration. Copyright © by the American Society of Agronomy, Crop Science Society of America, and Soil Science Society of America, Inc.

  20. Phosphorus loss to runoff water twenty-four hours after application of liquid swine manure or fertilizer.

    Science.gov (United States)

    Tabbara, Hadi

    2003-01-01

    Phosphorus (P) added to soil from fertilizer or manure application could pose a threat to water quality due to its role in eutrophication of fresh water resources. Incorporating such amendments into the soil is an established best management practice (BMP) for reducing soluble P losses in runoff water, but could also lead to higher erosion. The objective of this study was to test whether incorporation of manure or fertilizer 24 h before an intense rain could also reduce sediment-bound and total phosphorus (TP) losses in runoff. A rainfall simulation study was conducted on field plots (sandy loam with 6-7% slope, little surface residue, recently cultivated) that received two application rates of liquid swine manure or liquid ammonium polyphosphate fertilizer, using either surface-broadcast or incorporated methods of application. Incorporation increased the total suspended solids (TSS) concentrations in runoff but mass losses were not affected. Incorporation also reduced flow-weighted concentrations and losses of dissolved reactive phosphorus (DRP) and TP by as much as 30 to 60% depending on source (fertilizer vs. manure) and application rate. Phosphorus is moved below the mixing zone of interaction on incorporation, and thus the effect of the amount and availability of P in this zone is more important than cultivation on subsequent P losses in runoff. Incorporating manure or fertilizer in areas of intense erosive rain, recent extensive tillage, and with little or no surface residue is therefore a best management practice that should be adhered to in order to minimize contamination of surface water. Results also show comparatively lower P losses from manure than fertilizer.

  1. Gauging leaf-level contributions to landscape-level water loss within a Western US dryland fores

    Science.gov (United States)

    Murphy, P.; Potts, D. L.; Minor, R. L.; Hamerlynck, E. P.; Sutter, L., Jr.; Barron-Gafford, G.

    2017-12-01

    Western US forests represent a large constituent of the North American water and carbon cycles, yet the primary controls on water loss from these ecosystems remains unknown. In dryland forests, such as those found in the Southwestern US, water availability is key to ecosystem function, and the timing and magnitude of water loss can have lasting effects on the health of these communities. One poorly defined part of the water balance in these forests is the partitioning of evapotranspiration (ET) into evaporation (E; blue flow) to transpiration (T; green flow). A study of water fluxes at multiple scales in a semiarid montane forest in Southern Arizona speaks to the partitioning of these two water flows. Within the footprint of an eddy covariance system, which estimates ecosystem ET, we have examined the impacts of variation in climate, species makeup, and topographic position on E and T. This was done using leaf-level measures of T, pedon-scale measures of E, and whole-tree water loss by way of sap flux sensors. Where available, we have examined E, T, and ET fluxes across multiple seasons and years of highly variable precipitation records. Understanding the partitioning of ET is crucial, considering that projected changes to dryland ecosystems include longer periods of drought separated by heavier precipitation events. At a moment when potential impacts of changing climate on dryland structure and function are poorly understood, a stronger comprehension of these blue and green water flows is necessary to forecast the productivity of Western US forests into the future.

  2. Whole-field macro- and micro-deformation characteristic of unbound water-loss in dentin hard tissue.

    Science.gov (United States)

    Chen, Zhenning; Nadeau, Bobby; Yu, Kevin; Shao, Xinxing; He, Xiaoyuan; Goh, M Cynthia; Kishen, Anil

    2018-04-06

    High-resolution deformation measurements in a functionally graded hard tissue such as human dentin are essential to understand the unbound water-loss mediated changes and their role in its mechanical integrity. Yet a whole-field, 3-dimensional (3D) measurement and characterization of fully hydrated dentin in both macro- and micro-scales remain to be a challenge. This study was conducted in 2 stages. In stage-1, a stereo-digital image correlation approach was utilized to determine the water-loss and load-induced 3D deformations of teeth in a sagittal section over consecutively acquired frames, from a fully hydrated state to nonhydrated conditions for a period up to 2 hours. The macroscale analysis revealed concentrated residual deformations at the dentin-enamel-junction and the apical regions of root in the direction perpendicular to the dentinal tubules. Significant difference in the localized deformation characteristics was observed between the inner and outer aspects of the root dentin. During quasi-static loadings, further increase in the residual deformation was observed in the dentin. In stage-2, dentin microstructural variations induced by dynamic water-loss were assessed with environmental scanning electron microscopy and atomic force microscopy (AFM), showing that the dynamic water-loss induced distention of dentinal tubules with concave tubular edges, and concurrent contraction of intertubular dentin with convex profile. The findings from the current macro- and micro-scale analysis provided insight on the free-water-loss induced regional deformations and ultrastructural changes in human dentin. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  3. Simulation of the Gamma Dose Rate in Loss of Pool Water Accident of the Second Egyptian Research Reactor ETRR-2

    International Nuclear Information System (INIS)

    Amin, E.; Saleh, H.; Ashoub, N.

    2000-01-01

    The Second Egyptian Research Reactor ETRR-2, is a pool type reactor, a sudden loss of pool water resulting of leaving the core region un-covered. The reactor core is surrounded by chimney chambers whose water is isolated from pool water. This accident would lead to significant external dose. A model is developed and is used to calculate the dose rates for key access and traffic plans from indirect line of sight of the core have a maximum dose rate. The model developed uses the discrete ordinate method as implemented in the code DOT 3.5

  4. Rapid molecular detection of invasive species in ballast and harbor water by integrating environmental DNA and light transmission spectroscopy.

    Science.gov (United States)

    Egan, Scott P; Grey, Erin; Olds, Brett; Feder, Jeffery L; Ruggiero, Steven T; Tanner, Carol E; Lodge, David M

    2015-04-07

    Invasive species introduced via the ballast water of commercial ships cause enormous environmental and economic damage worldwide. Accurate monitoring for these often microscopic and morphologically indistinguishable species is challenging but critical for mitigating damages. We apply eDNA sampling, which involves the filtering and subsequent DNA extraction of microscopic bits of tissue suspended in water, to ballast and harbor water sampled during a commercial ship's 1400 km voyage through the North American Great Lakes. Using a lab-based gel electrophoresis assay and a rapid, field-ready light transmission spectroscopy (LTS) assay, we test for the presence of two invasive species: quagga (Dreissena bugensis) and zebra (D. polymorpha) mussels. Furthermore, we spiked a set of uninfested ballast and harbor samples with zebra mussel tissue to further test each assay's detection capabilities. In unmanipulated samples, zebra mussel was not detected, while quagga mussel was detected in all samples at a rate of 85% for the gel assay and 100% for the LTS assay. In the spiked experimental samples, both assays detected zebra mussel in 94% of spiked samples and 0% of negative controls. Overall, these results demonstrate that eDNA sampling is effective for monitoring ballast-mediated invasions and that LTS has the potential for rapid, field-based detection.

  5. Characterization of two-phase mixture (petroleum, salted water or gas) by gamma radiation transmission

    International Nuclear Information System (INIS)

    Eichlt, Jair Romeu

    2003-01-01

    A mathematical description was accomplished to determine the discrimination of a substance in a two-phase mixture, for one beam system, using the five energy lines (13.9, 17.8,26.35 and 59,54 keV) of the 241 Am source. The mathematical description was also accomplished to determine the discrimination of two substances in a three-phase mixture, for a double beam system.. he simulated mixtures for the one beam system were petroleum/salted water or gas. The materials considered in these simulations were: four oils types, denominated as A, B, Bell and Generic, one kind of natural gas and salted water with the following salinities: 35.5, 50, 100, 150, 200, 250 and 300 kg/m 3 of Na Cl. The simulation for the one beam system consisted of a box with acrylic walls and other situation with a box of epoxi walls reinforced with fiber of carbon. The epoxi with carbon fiber was used mainly due to the fact that this material offers little attenuation to the fotons and it resists great pressures. With the results of the simulations it was calculated tables of minimum discrimination for each possible two-phase mixture with petroleum, gas and salted water at several salinities. These discrimination tables are the theoretical forecasts for experimental measurements, since they supply the minimum mensurable percentage for each energy line, as well as the ideal energy for the measurement of each mixture, or situation. The simulated discrimination levels were tested employing experimental arrangements with conditions and materials similar to those of the simulations, for the case of box with epoxi wall reinforced with carbon fiber, at the energies of 20.8 and 59.54 keV. It was obtained good results. For example, for the mixture of salted water (35.5 kg/m 3 ) in paraffin (simulating the petroleum), it was obtained an experimental discrimination minimum of 10% of salted water for error statistics of 5% in I and I o , while the theoretical simulation foresaw the same discrimination level

  6. Loss of Propiconazole and its Four Stereoisomers from the Water Phase of Two Soil-Water Slurries as Measured by Capillary Electrophoresis

    Science.gov (United States)

    Propiconazole is a chiral fungicide used in agriculture for control of many fungal diseases on a variety of crops. This use provides opportunities for pollution of soil and, subsequently, groundwater. The rate of loss of propiconazole from the water phase of two different soil-wa...

  7. Extreme learning machine: a new alternative for measuring heat collection rate and heat loss coefficient of water-in-glass evacuated tube solar water heaters.

    Science.gov (United States)

    Liu, Zhijian; Li, Hao; Tang, Xindong; Zhang, Xinyu; Lin, Fan; Cheng, Kewei

    2016-01-01

    Heat collection rate and heat loss coefficient are crucial indicators for the evaluation of in service water-in-glass evacuated tube solar water heaters. However, the direct determination requires complex detection devices and a series of standard experiments, wasting too much time and manpower. To address this problem, we previously used artificial neural networks and support vector machine to develop precise knowledge-based models for predicting the heat collection rates and heat loss coefficients of water-in-glass evacuated tube solar water heaters, setting the properties measured by "portable test instruments" as the independent variables. A robust software for determination was also developed. However, in previous results, the prediction accuracy of heat loss coefficients can still be improved compared to those of heat collection rates. Also, in practical applications, even a small reduction in root mean square errors (RMSEs) can sometimes significantly improve the evaluation and business processes. As a further study, in this short report, we show that using a novel and fast machine learning algorithm-extreme learning machine can generate better predicted results for heat loss coefficient, which reduces the average RMSEs to 0.67 in testing.

  8. Evaporative water loss is a plausible explanation for mortality of bats from white-nose syndrome.

    Science.gov (United States)

    Willis, Craig K R; Menzies, Allyson K; Boyles, Justin G; Wojciechowski, Michal S

    2011-09-01

    White-nose syndrome (WNS) has caused alarming declines of North American bat populations in the 5 years since its discovery. Affected bats appear to starve during hibernation, possibly because of disruption of normal cycles of torpor and arousal. The importance of hydration state and evaporative water loss (EWL) for influencing the duration of torpor bouts in hibernating mammals recently led to "the dehydration hypothesis," that cutaneous infection of the wing membranes of bats with the fungus Geomyces destructans causes dehydration which in turn, increases arousal frequency during hibernation. This hypothesis predicts that uninfected individuals of species most susceptible to WNS, like little brown bats (Myotis lucifugus), exhibit high rates of EWL compared to less susceptible species. We tested the feasibility of this prediction using data from the literature and new data quantifying EWL in Natterer's bats (Myotis nattereri), a species that is, like other European bats, sympatric with G. destructans but does not appear to suffer significant mortality from WNS. We found that little brown bats exhibited significantly higher rates of normothermic EWL than did other bat species for which comparable EWL data are available. We also found that Natterer's bats exhibited significantly lower rates of EWL, in both wet and dry air, compared with values predicted for little brown bats exposed to identical relative humidity (RH). We used a population model to show that the increase in EWL required to cause the pattern of mortality observed for WNS-affected little brown bats was small, equivalent to a solitary bat hibernating exposed to RH of ∼95%, or clusters hibernating in ∼87% RH, as opposed to typical near-saturation conditions. Both of these results suggest the dehydration hypothesis is plausible and worth pursuing as a possible explanation for mortality of bats from WNS.

  9. Zinc corrosion after loss-of-coolant accidents in pressurized water reactors – Physicochemical effects

    Energy Technology Data Exchange (ETDEWEB)

    Kryk, Holger, E-mail: h.kryk@hzdr.de [Helmholtz-Zentrum Dresden-Rossendorf, Institute of Fluid Dynamics, P.O. Box 510119, D-01314 Dresden (Germany); Hoffmann, Wolfgang [Helmholtz-Zentrum Dresden-Rossendorf, Institute of Fluid Dynamics, P.O. Box 510119, D-01314 Dresden (Germany); Kästner, Wolfgang; Alt, Sören; Seeliger, André; Renger, Stefan [Hochschule Zittau/Görlitz, Institute of Process Technology, Process Automation and Measuring Technology, Theodor-Körner-Allee 16, D-02763 Zittau (Germany)

    2014-12-15

    Highlights: • Physicochemical effects due to post-LOCA zinc corrosion in PWR were elucidated. • Decreasing solubility of corrosion products with increasing temperature was found. • Solid corrosion products may be deposited on hot surfaces and/or within hot-spots. • Corrosion products precipitating from coolant were identified as zinc borates. • Depending on coolant temperature, different types of zinc borate are formed. - Abstract: Within the framework of the reactor safety research, generic experimental investigations were carried out aiming at the physicochemical background of possible zinc corrosion product formation, which may occur inside the reactor pressure vessel during the sump circulation operation after loss-of-coolant accidents in pressurized water reactors. The contact of the boric acid containing coolant with hot-dip galvanized steel containment internals causes corrosion of the corresponding materials resulting in dissolution of the zinc coat. A retrograde solubility of zinc corrosion products with increasing temperature was observed during batch experiments of zinc corrosion in boric acid containing coolants. Thus, the formation and deposition of solid corrosion products cannot be ruled out if the coolant containing dissolved zinc is heated up during its recirculation into hot regions within the emergency cooling circuit (e.g. hot-spots in the core). Corrosion experiments at a lab-scale test facility, which included formation of corrosion products at a single heated cladding tube, proved that dissolved zinc, formed at low temperatures in boric acid solution by zinc corrosion, turns into solid deposits of zinc borates when contacting heated zircaloy surfaces during the heating of the coolant. Moreover, the temperature of formation influences the chemical composition of the zinc borates and thus the deposition and mobilization behavior of the products.

  10. DFD-01 Reduces Transepidermal Water Loss and Improves Skin Hydration and Flexibility.

    Science.gov (United States)

    Jackson, J Mark; Grove, Gary L; Allenby, Kent; Houser, Tim

    2017-12-01

    In plaque psoriasis, the benefit of topical steroids is well established. The vehicle formulation of topical steroids may also provide benefit in addition to the effects of the steroid itself. DFD-01 (betamethasone dipropionate spray, 0.05%) is a formulation composed of a topical steroid in an emollient-like vehicle that enhances penetration to the target site of inflammation in the skin. The aim of this study was to assess the effect of DFD-01 and its vehicle on skin hydration and barrier function in compromised skin and to evaluate its effect on flexibility in healthy skin. Eighteen healthy white volunteers were enrolled in each of two studies. In Study 1, dry shaving of volar forearms created a compromised skin barrier, through which transepidermal water loss (TEWL) was measured using an evaporimeter. Capacitance, a measure of epidermal hydration, was also measured at baseline and at 1, 2 and 4 h after application of DFD-01 or its vehicle formulation. In Study 2, intact skin flexibility was tested with a cutometer before and at 1, 2 and 4 h after application of DFD-01 or vehicle. In Study 1, both DFD-01 and its vehicle were effective at reducing TEWL through the compromised stratum corneum. Capacitance measurements confirmed this finding; razor-chafed skin treated with either DFD-01 or vehicle exhibited levels of skin hydration similar to unshaved control skin. Study 2 found softening and greater flexibility of normal skin treated with either DFD-01 or vehicle compared with nontreated control skin samples. These tests suggest that the DFD-01 formulation and its vehicle are each effective at retaining moisture within a damaged skin barrier and for softening and increasing the flexibility of intact skin. Dr. Reddy's Laboratories.

  11. Zinc corrosion after loss-of-coolant accidents in pressurized water reactors – Physicochemical effects

    International Nuclear Information System (INIS)

    Kryk, Holger; Hoffmann, Wolfgang; Kästner, Wolfgang; Alt, Sören; Seeliger, André; Renger, Stefan

    2014-01-01

    Highlights: • Physicochemical effects due to post-LOCA zinc corrosion in PWR were elucidated. • Decreasing solubility of corrosion products with increasing temperature was found. • Solid corrosion products may be deposited on hot surfaces and/or within hot-spots. • Corrosion products precipitating from coolant were identified as zinc borates. • Depending on coolant temperature, different types of zinc borate are formed. - Abstract: Within the framework of the reactor safety research, generic experimental investigations were carried out aiming at the physicochemical background of possible zinc corrosion product formation, which may occur inside the reactor pressure vessel during the sump circulation operation after loss-of-coolant accidents in pressurized water reactors. The contact of the boric acid containing coolant with hot-dip galvanized steel containment internals causes corrosion of the corresponding materials resulting in dissolution of the zinc coat. A retrograde solubility of zinc corrosion products with increasing temperature was observed during batch experiments of zinc corrosion in boric acid containing coolants. Thus, the formation and deposition of solid corrosion products cannot be ruled out if the coolant containing dissolved zinc is heated up during its recirculation into hot regions within the emergency cooling circuit (e.g. hot-spots in the core). Corrosion experiments at a lab-scale test facility, which included formation of corrosion products at a single heated cladding tube, proved that dissolved zinc, formed at low temperatures in boric acid solution by zinc corrosion, turns into solid deposits of zinc borates when contacting heated zircaloy surfaces during the heating of the coolant. Moreover, the temperature of formation influences the chemical composition of the zinc borates and thus the deposition and mobilization behavior of the products

  12. Analysis of water hammer in a penstock in the case of valve closure. Part 2: Pressure losses concentrated downstream

    Directory of Open Access Journals (Sweden)

    Hocine HAMMOUM

    2017-06-01

    Full Text Available In our previous study (Part 1; by using the graphic of Bergeron, we have drawn the relationships which allow calculating flows and pressures at the valve and the reservoir, considering that pressure losses are negligible. Now, we assume in this second contribution that these pressure losses are concentrated downstream of the pipe, just at the entry of the valve. The study will focus on water hammer-induced by a slow closing of the valve. A practical example will be presented at the end of this work in order to illustrate the exposed method.

  13. Consumption of low-moderate level arsenic contaminated water does not increase spontaneous pregnancy loss: a case control study.

    Science.gov (United States)

    Bloom, Michael S; Neamtiu, Iulia A; Surdu, Simona; Pop, Cristian; Lupsa, Ioana Rodica; Anastasiu, Doru; Fitzgerald, Edward F; Gurzau, Eugen S

    2014-10-13

    Previous work suggests an increased risk for spontaneous pregnancy loss linked to high levels of inorganic arsenic (iAs) in drinking water sources (>10 μg/L). However, there has been little focus to date on the impact of low-moderate levels of iAs in drinking water (control study in Timis County, Romania. We recruited women with incident spontaneous pregnancy loss of 5-20 weeks completed gestation as cases (n = 150), and women with ongoing pregnancies matched by gestational age (±1 week) as controls (n = 150). Participants completed a physician-administered questionnaire and we collected water samples from residential drinking sources. We reconstructed residential drinking water exposure histories using questionnaire data weighted by iAs determined using hydride generation-atomic absorption spectrometry (HG-AAS). Logistic regression models were used to generate odds ratios (OR) and 95% confidence intervals (CI) for associations between iAs exposure and loss, conditioned on gestational age and adjusted for maternal age, cigarette smoking, education and prenatal vitamin use. We explored potential interactions in a second set of models. Drinking water arsenic concentrations ranged from 0.0 to 175.1 μg/L, with median 0.4 μg/L and 90th%tile 9.4 μg/L. There were no statistically significant associations between loss and average or peak drinking water iAs concentrations (OR 0.98, 95% CI 0.96-1.01), or for daily iAs intake (OR 1.00, 95% CI 0.98-1.02). We detected modest evidence for an interaction between average iAs concentration and cigarette smoking during pregnancy (P = 0.057) and for daily iAs exposure and prenatal vitamin use (P = 0.085). These results suggest no increased risk for spontaneous pregnancy loss in association with low to moderate level drinking water iAs exposure. Though imprecise, our data also raise the possibility for increased risk among cigarette smokers. Given the low exposures overall, these data should reassure pregnant

  14. Metabolic rate, evaporative water loss and thermoregulatory state in four species of bats in the Negev desert.

    Science.gov (United States)

    Muñoz-Garcia, Agustí; Larraín, Paloma; Ben-Hamo, Miriam; Cruz-Neto, Ariovaldo; Williams, Joseph B; Pinshow, Berry; Korine, Carmi

    2016-01-01

    Life in deserts is challenging for bats because of their relatively high energy and water requirements; nevertheless bats thrive in desert environments. We postulated that bats from desert environments have lower metabolic rates (MR) and total evaporative water loss (TEWL) than their mesic counterparts. To test this idea, we measured MR and TEWL of four species of bats, which inhabit the Negev desert in Israel, one species mainly restricted to hyper-arid deserts (Otonycteris hemprichii), two species from semi-desert areas (Eptesicus bottae and Plecotus christii), and one widespread species (Pipistrellus kuhlii). We also measured separately, in the same individuals, the two components of TEWL, respiratory water loss (RWL) and cutaneous evaporative water loss (CEWL), using a mask. In all the species, MR and TEWL were significantly reduced during torpor, the latter being a consequence of reductions in both RWL and CEWL. Then, we evaluated whether MR and TEWL in bats differ according to their geographic distributions, and whether those rates change with Ta and the use of torpor. We did not find significant differences in MR among species, but we found that TEWL was lowest in the species restricted to desert habitats, intermediate in the semi-desert dwelling species, and highest in the widespread species, perhaps a consequence of adaptation to life in deserts. Our results were supported by a subsequent analysis of data collected from the literature on rates of TEWL for 35 bat species from desert and mesic habitats. Copyright © 2015 Elsevier Inc. All rights reserved.

  15. Stable Carbon Isotope Characterization of CO2 Loss in Acid Mine Drainage Impacted Stream Water: Observations from a Laboratory Experiment

    Science.gov (United States)

    Ali, H. N.; Atekwana, E. A.

    2007-05-01

    Water from an acid mine drainage spring, ground water from a mine tailings pile, stream water and tap water were acidified to simulate acid mine drainage (AMD) contamination. The objective was to determine how acidification of stream water by AMD affected DIC loss and carbon isotope fraction. Two 20 L HDP containers (reactors) containing samples from each source were left un-acidified and allowed to evolve under ambient conditions for several weeks in the laboratory and two others were acidified. Acidification was carried out progressively with sulfuric acid to pH <3. For acidified samples, one reactor was acidified open to the atmosphere and the other closed from contact with atmosphere and CO2(g) was collected under vacuum. The un-acidified samples did not show significant alkalinity and DIC loss, and the 13C of DIC was enriched with time. The acidified samples showed decrease in alkalinity and DIC and increase in the 13C of DIC and CO2(g) with progressive acidification. The enrichment of 13C of DIC for un-acidified samples was due to exchange with atmospheric CO2. On the other hand, the 13C enrichment in the acidified samples was due to fractionation during dehydration of HCO3- and diffusive loss of CO2(g) from the aqueous phase. The actual values measured depended on the amount of CO2 lost from the aqueous phase during acidification. Samples with greater CO2 loss (closed acidification) had greater 13C enrichment. Beyond the HCO3- titration end point, the δ13C of DIC and CO2(g) was similar and nearly constant. The result of this study suggests that AMD effects on DIC can be modeled as a first order kinetic reaction and the isotope enrichment modeled using Rayleigh distillation.

  16. Reformulating sunscreen cosmetics with better water resistance and efficacy to inhibit trans-epidermal water loss in response to global warming and climate change

    International Nuclear Information System (INIS)

    Sucgang, Raymond J.; Manalili, Jenalyn; Mañago, Sarah; Janio, Jonick; Ching, Maricar; Moya, Esperanza; Cruz, Luzviminda

    2015-01-01

    Three inhouse developed skin care formulations and four commercial formulations were tried out on dermatomed porcine skins for wettability and emoliency. Surface applied skin care formulations are alleged to reduce transepidermal water loss (TEWL). Sunscreens/sunblocks absorb or reflect the sun’s ultraviolet (UV) radiation on skin exposed to sunlight and thus helps protect against sunburn. Measurements of water resistance of topical application are normally done using contact angle measurements and swimming pool immersion approaches. TEWL is measured using vapometers. None of the conventional methods directly measure TEWL and water wash out rates. In this study, the effectiveness of skin moisturizers to inhibit TEWL was tested using tritiated water as radioactive tracer on degreased porcine skins. Topical emollients were applied on the epidermises of the skins and the skins were mounted epidermis facing down. Tritiated water was dropped on the top side of the skins and tritium activity concentrations of the moisture that passed through were measured. A modified immersion method was also developed as a screening tool to identify water resistant formulations. Sunscreens labelled with tritiated water were applied on the skin surfaces. The skins were immersed in water (distilled and sea water were compared) and aliquots of the water were counted for tritium every hour for 3 hours. Hydrophobicities of the formulations were predicted by the amounts of tritium that leached out from the skins. (author)

  17. Characteristics of Soil and Organic Carbon Loss Induced by Water Erosion on the Loess Plateau in China.

    Science.gov (United States)

    Li, Zhongwu; Nie, Xiaodong; Chang, Xiaofeng; Liu, Lin; Sun, Liying

    2016-01-01

    Soil erosion has been a common environmental problem in the Loess Plateau in China. This study aims to better understand the losses of soil organic carbon (SOC) induced by water erosion. Laboratory-simulated rainfall experiments were conducted to investigate the characteristics of SOC loss induced by water erosion. The applied treatments included two rainfall intensities (90 and 120 mm h-1), four slope gradients (10°, 15°, 20°, and 25°), and two typical soil types- silty clay loam and silty loam. Results showed that the sediment OC enrichment ratios (ERoc) in all the events were relative stable with values ranged from 0.85 to1.21 and 0.64 to 1.52 and mean values of 0.98 and 1.01 for silty clay loam and silty loam, respectively. Similar to the ERoc, the proportions of different sized particles in sediment showed tiny variations during erosion processes. No significant correlation was observed between ERoc values and the proportions of sediment particles. Slope, rainfall intensity and soil type almost had no impact on ERoc. These results indicate that the transportation of SOC during erosion processes was nonselective. While the mean SOC loss rates for the events of silty clay loam and silty loam were 0.30 and 0.08 g m-2 min-1, respectively. Greater differences in SOC loss rates were found in events among different soil types. Meanwhile, significant correlations between SOC loss and soil loss for all the events were observed. These results indicated that the amount of SOC loss was influenced primarily by soil loss and the SOC content of the original soil. Erosion pattern and original SOC content are two main factors by which different soils can influence SOC loss. It seems that soil type has a greater impact on SOC loss than rainfall characteristics on the Loess Plateau of China. However, more kinds of soils should be further studied due to the special formation processes in the Loess Plateau.

  18. ACCOUNTING OF REACTIVE POWER COMPENSATION LEVEL AT PAYMENT CALCULATION OF TECHNOLOGICAL CONSUMPTION (LOSSES OF ELECTRIC POWER FOR ITS TRANSMISSION IN POWER NETWORK

    Directory of Open Access Journals (Sweden)

    E. P. Zabello

    2005-01-01

    Full Text Available The method is proposed to make a correction in payment for consumption of reactive energy and power which is attributed to deviation of actual activation energy losses for reactive power compensation from their standard value. It is recommended to calculate standard loss values for every voltage level and actual loss values are to be determined with the help of application of remote electronic accounting means in the current mode of power consumption.

  19. Compensatory vapor loss and biogeochemical attenuation along flowpaths mute the water resources impacts of insect-induced forest mortality

    Science.gov (United States)

    Biederman, J. A.; Brooks, P. D.; Harpold, A. A.; Gochis, D. J.; Ewers, B. E.; Reed, D. E.; Gutmann, E. D.

    2013-12-01

    Forested montane catchments are critical to the amount and quality of downstream water resources. In western North America more than 60 million people rely on mountain precipitation, and water managers face uncertain response to an unprecedented forest die-off from mountain pine beetle (MPB) infestation. Reduced snow interception and transpiration are expected to increase streamflow, while increased organic matter decay is expected to increase biogeochemical stream fluxes. Tree- to plot-scale observations have documented some of the expected changes, but there has been little significant change to streamflow or water quality at the larger scales relevant to water resources. A critical gap exists in our understanding of why tree-scale process changes have not led to the expected, large-scale increases in streamflow and biogeochemical fluxes. We address this knowledge gap with observations of water and biogeochemical fluxes at nested spatial scales including tree, hillslope, and catchments from 3 to 700 ha with more than 75% mortality. Catchment discharge showed reduced water yield consistent with co-located eddy covariance observations showing increased vapor losses following MPB. Stable water isotopes showed progressive kinetic fractionation (i.e. unsaturated transition layer above the evaporating surface) in snowpack, soil water and streams indicating greater abiotic evaporation from multiple water sources offsetting decreased interception and transpiration. In the 3rd to 5th years following MPB forest mortality, soil water DOC and DON were similar beneath killed and healthy trees, but concentrations were elevated 2-10 times in groundwater of MPB-impacted sites as compared to unimpacted. Stream water DOC and DON were about 3 times as large during snowmelt runoff in ephemeral zero-order channels of MPB-impacted sites compared to unimpacted. Processing in the headwater streams of MPB-impacted forests rapidly attenuated dissolved organic matter. From the MPB

  20. The South-to-North Water Diversion Project: effect of the water diversion pattern on transmission of Oncomelania hupensis, the intermediate host of Schistosoma japonicum in China.

    Science.gov (United States)

    Liang, You-Sheng; Wang, Wei; Li, Hong-Jun; Shen, Xue-Hui; Xu, Yong-Liang; Dai, Jian-Rong

    2012-03-20

    The South-to-North Water Diversion Project (SNWDP) is the largest national water conservancy project in China. However, the Eastern Route Project (ERP) of SNWDP will refer to the habitats of Oncomelania hupensis, the intermediate host of Schistosoma japonicum. The present study was aimed at investigating the effects of some factors relating to the water diversion pattern on the spread north of O. hupensis and transmission of S. japonicum. Marked snails were attached to the floating debris, and then placed on the water surface, the passage of snails through water pumps was observed. Some marked living adult snails were placed under water in the 5 spots, 15, 30, 60, 90 and 120 days later, their survival and transfer under water were investigated. 2, 4, 8, 16, 32, 64 and 128 juvenile snails, with a male: female ratio of about 1, were caged, 1 year later, their reproductions were calculated. The snails attached on the floating debris at 100-, 50- and 20-cm-distance from the inlet pipe of the big pump (with a diameter of 80 cm), could be absorbed into the pumps, with passing rates of 2.45%, 3.93% and 43.46%, respectively, compared with 72.07% and 91.00% for the snails at 20 cm and 10 cm-distance from the inlet pipe of the small pump (with a diameter of 20 cm). A total of 36,600 marked living snails were put into 5 ponds and ditches, with the water depths of 1-1.6 m, 15-120 days later, no marked ones were found along the ponds and ditches or in the straw packages. The juvenile snails did not reproduce until their density reached up to 8 snails (ratio of male: female of 1)/0.16 m2. During the construction of ERP of SNWDP, the risk of northward spread of schistosomiasis japonica will be decreased or eliminated as long as long-term reliable interventions for snail control are implemented.

  1. Estimating water losses as a result of food waste in South Africa

    CSIR Research Space (South Africa)

    Oelofse, Suzanna HH

    2013-09-01

    Full Text Available Globally there are sufficient land and water resources to produce food over the next 50 years, but only if water for agriculture is better managed (Molden, 2007). Water is a critical and strategic natural resource in South Africa. It is essential...

  2. Streamflow gain and loss and water quality in the upper Nueces River Basin, south-central Texas, 2008-10

    Science.gov (United States)

    Banta, J. Ryan; Lambert, Rebecca B.; Slattery, Richard N.; Ockerman, Darwin J.

    2012-01-01

    The U.S. Geological Survey-in cooperation with the U.S. Army Corps of Engineers, The Nature Conservancy, the Real Edwards Conservation and Reclamation District, and the Texas Parks and Wildlife Department-investigated streamflow gain and loss and water quality in the upper Nueces River Basin, south-central Texas, specifically in the watersheds of the West Nueces, Nueces, Dry Frio, Frio, and Sabinal Rivers upstream from the Edwards aquifer outcrop. Streamflow in these rivers is sustained by groundwater contributions (for example, from springs) and storm runoff from rainfall events. To date (2012), there are few data available that describe streamflow and water-quality conditions of the rivers within the upper Nueces River Basin. This report describes streamflow gain-loss characteristics from three reconnaissance-level synoptic measurement surveys (hereinafter referred to as "surveys") during 2008-10 in the upper Nueces River Basin. To help characterize the hydrology, groundwater-level measurements were made, and water-quality samples were collected from both surface-water and groundwater sites in the study area from two surveys during 2009-10. The hydrologic (streamflow, springflow, and groundwater) measurements were made during three reconnaissance-level synoptic measurement surveys occurring in July 21-23, 2008; August 8-18, 2009; and March 22-24, 2010. These survey periods were selected to represent different hydrologic conditions. Streamflow gains and losses were based on streamflow and springflow measurements made at 74 sites in the study area, although not all sites were measured during each survey. Possible water chemistry relations among sample types (streamflow, springflow, or groundwater), between surveys, and among watersheds were examined using water-quality samples collected from as many as 20 sites in the study area.

  3. SCDAP/RELAP5 modeling of fluid heat transfer and flow losses through porous debris in a light water reactor

    International Nuclear Information System (INIS)

    Harvego, E. A.; Siefken, L. J.

    2000-01-01

    The SCDAP/RELAP5 code is being developed at the Idaho National Engineering and Environmental Laboratory under the primary sponsorship of the U.S. Nuclear Regulatory Commission (NRC) to provide best-estimate transient simulations of light water reactor coolant systems during severe accidents. This paper describes the modeling approach used in the SCDAP/RELAP5 code to calculate fluid heat transfer and flow losses through porous debris that has accumulated in the vessel lower head and core regions during the latter stages of a severe accident. The implementation of heat transfer and flow loss correlations into the code is discussed, and calculations performed to assess the validity of the modeling approach are described. The different modes of heat transfer in porous debris include: (1) forced convection to liquid, (2) forced convection to gas, (3) nucleate boiling, (4) transition boiling, (5) film boiling, and (6) transition from film boiling to convection to vapor. The correlations for flow losses in porous debris include frictional and form losses. The correlations for flow losses were integrated into the momentum equations in the RELAP5 part of the code. Since RELAP5 is a very general non-homogeneous non-equilibrium thermal-hydraulics code, the resulting modeling methodology is applicable to a wide range of debris thermal-hydraulic conditions. Assessment of the SCDAP/RELAP5 debris bed thermal-hydraulic models included comparisons with experimental measurements and other models available in the open literature. The assessment calculations, described in the paper, showed that SCDAP/RELAP5 is capable of calculating the heat transfer and flow losses occurring in porous debris regions that may develop in a light water reactor during a severe accident

  4. Analysis of factors causing signal loss in the measurement of lung tissue water by nuclear magnetic resonance

    International Nuclear Information System (INIS)

    Fukuzaki, Minoru; Shioya, Sumie; Haida, Munetaka

    1997-01-01

    The water content of lung, brain, and muscle tissue was measured by nuclear magnetic resonance (NMR) and compared with gravimetric determinations. The NMR signal intensity of water was measured by a single 90 degree pulse and by a spin-echo sequence. The absolute water content was determined by the difference in the sample's weight before and after desiccation. The NMR detectable water in each tissue was expressed as a percentage of the signal intensity for an equal weight of distilled water. Using the single pulse measurement, 67% of the gravimetrically-measured water was detected in collapsed lung samples (consisting of about 47% retained air), in contrast to 96% for brain and 98% for muscle. For degassed lung samples, the NMR detectability of water increased to 87% with the single pulse measurement and to 90% with the spin-echo measurement, but the values remained significantly less than those of brain or muscle. Factors that caused the NMR signal loss of 33% in collapsed lung samples were: air-tissue interfaces (20%), microscopic field inhomogeneity (3%), and a water component with an extremely short magnetization decay time constant (10%). (author)

  5. Using ecotechnology to address water quality and wetland habitat loss problems in the Mississippi basin: a hierarchical approach.

    Science.gov (United States)

    Day, John W; Yañéz Arancibia, Alejandro; Mitsch, William J; Lara-Dominguez, Ana Laura; Day, Jason N; Ko, Jae-Young; Lane, Robert; Lindsey, Joel; Lomeli, David Zarate

    2003-12-01

    Human activities are affecting the environment at continental and global scales. An example of this is the Mississippi basin where there has been a large scale loss of wetlands and water quality deterioration over the past century. Wetland and riparian ecosystems have been isolated from rivers and streams. Wetland loss is due both to drainage and reclamation, mainly for agriculture, and to isolation from the river by levees, as in the Mississippi delta. There has been a decline in water quality due to increasing use of fertilizers, enhanced drainage and the loss of wetlands for cleaning water. Water quality has deteriorated throughout the basin and high nitrogen in the Mississippi river is causing a large area of hypoxia in the Gulf of Mexico adjacent to the Mississippi delta. Since the causes of these problems are distributed over the basin, the solution also needs to be distributed over the basin. Ecotechnology and ecological engineering offer the only ecologically sound and cost-effective method of solving these problems. Wetlands to promote nitrogen removal, mainly through denitrification but also through burial and plant uptake, offer a sound ecotechnological solution. At the level of the Mississippi basin, changes in farming practices and use of wetlands for nitrogen assimilation can reduce nitrogen levels in the River. There are additional benefits of restoration of wetland and riverine ecosystems, flood control, reduction in public health threats, and enhanced wildlife and fisheries. At the local drainage basin level, the use of river diversions in the Mississippi delta can address both problems of coastal land loss and water quality deterioration. Nitrate levels in diverted river water are rapidly reduced as water flows through coastal watersheds. At the local level, wetlands are being used to treat municipal wastewater. This is a cost-effective method, which results in improved water quality, enhanced wetland productivity and increased accretion. The

  6. Dimerization and DNA-binding of ASR1, a small hydrophilic protein abundant in plant tissues suffering from water loss

    International Nuclear Information System (INIS)

    Maskin, Laura; Frankel, Nicolas; Gudesblat, Gustavo; Demergasso, Maria J.; Pietrasanta, Lia I.; Iusem, Norberto D.

    2007-01-01

    The Asr gene family is present in Spermatophyta. Its members are generally activated under water stress. We present evidence that tomato ASR1, one of the proteins of the family, accumulates in seed during late stages of embryogenesis, a physiological process characterized by water loss. In vitro, electrophoretic assays show a homo-dimeric structure for ASR1 and highlight strong non-covalent interactions between monomers prone to self-assemble. Direct visualization of single molecules by atomic force microscopy (AFM) confirms that ASR1 forms homodimers and that uncovers both monomers and dimers bind double stranded DNA

  7. A Study on Distribution Measurement and Mechanism of Deformation due to Water Loss of Overburden Layer in Vertical Shaft

    Directory of Open Access Journals (Sweden)

    Chunde Piao

    2015-01-01

    Full Text Available Based on FBG fiber Bragg grating technology and BOTDA distributed optical fiber sensing technology, this study uses fine sand to simulate overburden layer in vertical shaft model equipment. It studies the placing technique and test method for optical fiber sensors in the overburden layer, combined with MODFLOW software to simulate the change of the water head value when the overburden layer is losing water, and obtains the deformation features of overburden layer. The results show, at the beginning of water loss, the vertical deformation increases due to larger hydraulic pressure drop, while the deformation decreases gradually and tends to be stable with the hydraulic pressure drop reducing. The circumferential deformation is closely related to such factors as the distance between each drainage outlet, the variations of water head value, and the method of drainage. The monitoring result based on optical fiber sensing technology is consistent with the characteristics of water loss in overburden layer simulated by MODFLOW software, which shows that the optical fiber sensing technology applied to monitor shaft overburden layer is feasible.

  8. The effect of low capacity injection systems on transient initiated loss of vessel water injection at Browns Ferry unit one

    International Nuclear Information System (INIS)

    Ott, L.T.

    1983-01-01

    Probabilistic risk assessment (PRA) analyses have indicated the transient initiated loss of vessel water injection (TQUV sequence) to be a dominant accident scenario for BWR plants. The PRA studies assumed the low capacity injection systems to be unimportant in severe accidents. The results of a Severe Accident Sequence Analysis (SASA) Program study have shown that these systems are capable of preventing or significantly delaying core damage in a TQUV sequence

  9. An effect of heat insulation parameters on thermal losses of water-cooled roofs for secondary steelmaking electric arc furnaces

    Directory of Open Access Journals (Sweden)

    E. Mihailov

    2016-07-01

    Full Text Available The aim of this work is research in the insulation parameters effect on the thermal losses of watercooled roofs for secondary steelmaking electric arc furnaces. An analytical method has been used for the investigation in heat transfer conditions in the working area. The results of the research can be used to choose optimal cooling parameters and select a suitable kind of insulation for water-cooled surfaces.

  10. Importance of water source in controlling leaf leaching losses in a dwarf red mangrove ( Rhizophora mangle L.) wetland

    Science.gov (United States)

    Davis, Stephen E., III; Childers, Daniel L.

    2007-01-01

    The southern Everglades mangrove ecotone is characterized by extensive dwarf Rhizophora mangle L. shrub forests with a seasonally variable water source (Everglades - NE Florida Bay) and residence times ranging from short to long. We conducted a leaf leaching experiment to understand the influence that water source and its corresponding water quality have on (1) the early decay of R. mangle leaves and (2) the early exchange of total organic carbon (TOC) and total phosphorus (TP) between leaves and the water column. Newly senesced leaves collected from lower Taylor River (FL) were incubated in bottles containing water from one of three sources (Everglades, ambient mangrove, and Florida Bay) that spanned a range of salinity from 0 to 32‰, [TOC] from 710 to 1400 μM, and [TP] from 0.17 to 0.33 μM. We poisoned half the bottles in order to quantify abiotic processes (i.e., leaching) and assumed that non-poisoned bottles represented both biotic (i.e., microbial) and abiotic processes. We sacrificed bottles after 1,2, 5, 10, and 21 days of incubation and quantified changes in leaf mass and changes in water column [TOC] and [TP]. We saw 10-20% loss of leaf mass after 24 h—independent of water treatment—that leveled off by Day 21. After 3 weeks, non-poisoned leaves lost more mass than poisoned leaves, and there was only an effect of salinity on mass loss in poisoned incubations—with greatest leaching-associated losses in Everglades freshwater. Normalized concentrations of TOC in the water column increased by more than two orders of magnitude after 21 days with no effect of salinity and no difference between poisoned and non-poisoned treatments. However, normalized [TP] was lower in non-poisoned incubations as a result of immobilization by epiphytic microbes. This immobilization was greatest in Everglades freshwater and reflects the high P demand in this ecosystem. Immobilization of leached P in mangrove water and Florida Bay water was delayed by several days and may

  11. Final environmental assessment for a refinement of the power delivery component of the Southern Nevada Water Authority Treatment and Transmission Facility

    International Nuclear Information System (INIS)

    1998-07-01

    The Southern Nevada Water Authority (SNWA) is designing and constructing a system of regional water supply facilities to meet current and projected water demands and increase system reliability. The existing Southern Nevada Water system is being upgraded with a number of improvements to increase the capacity of the system. However, even the expanded system is expected to be unable to meet projected peak daily water demands by the year 1999. As a result, new facilities are being designed and constructed to operate in conjunction with the upgraded Southern Nevada Water system. These new facilities, known as the Southern Nevada Water Authority Treatment and Transmission Facility (SNWA-TTF), include four primary components: a new raw water intake; new transmission facilities including below ground pipelines, tunnels, and above ground pumping stations; a water treatment facility; and new power supply facilities. Because existing power supplies would not be adequate for the new water treatment facilities, new power facilities, consisting of two new 230 kV-69 kV substations and new 69 and 230 kV power lines, are being constructed. This environmental assessment is specifically on the new power facilities

  12. Continuous recording of excretory water loss from Musca domestica using a flow-through humidity meter: hormonal control of diuresis.

    Science.gov (United States)

    Coast, Geoffrey M

    2004-05-01

    Water loss from adult male houseflies was continuously recorded using a flow-through humidity meter, which enabled losses to be apportioned between the sum of cuticular and respiratory transpiration, salivation and excretion. Transpiration accounted for >95% of water lost from sham-injected flies, compared with excretion (3.0%) and salivation (2.4%). In contrast, excretion accounted for 40% of water lost from flies injected with > or =3 microl of saline, whereas salivary losses were unchanged. Saline injections (1-5 microl) expanded the abdomen in the dorsal-ventral plane, and this expansion was positively correlated with the magnitude of the ensuing diuresis, suggesting the signal for diuretic hormone release originates from stretch receptors in abdominal tergal-sternal muscles. The effects of decapitation, severing the ventral nerve cord within the neck or ligaturing the neck, showed the head was needed to initiate and maintain diuresis, but was neither the source of diuretic hormone nor did it control the discharge of urine from the anus. These findings indicate the head is part of the neural-endocrine pathway between abdominal stretch receptors and sites for diuretic hormone release from the thoracic-abdominal ganglion mass. Evidence is presented for Musdo-K having a hormonal role in the control of diuresis, although other neuropeptides may also be implicated.

  13. Homeostasis in leaf water potentials on leeward and windward sides of desert shrub crowns: water loss control vs. high hydraulic efficiency.

    Science.gov (United States)

    Iogna, Patricia A; Bucci, Sandra J; Scholz, Fabián G; Goldstein, Guillermo

    2013-11-01

    Phenotypic plasticity in morphophysiological leaf traits in response to wind was studied in two dominant shrub species of the Patagonian steppe, used as model systems for understanding effects of high wind speed on leaf water relations and hydraulic properties of small woody plants. Morpho-anatomical traits, hydraulic conductance and conductivity and water relations in leaves of wind-exposed and protected crown sides were examined during the summer with nearly continuous high winds. Although exposed sides of the crowns were subjected to higher wind speeds and air saturation deficits than the protected sides, leaves throughout the crown had similar minimum leaf water potential (ΨL). The two species were able to maintain homeostasis in minimum ΨL using different physiological mechanisms. Berberis microphylla avoided a decrease in the minimum ΨL in the exposed side of the crown by reducing water loss by stomatal control, loss of cell turgor and low epidermal conductance. Colliguaja integerrima increased leaf water transport efficiency to maintain transpiration rates without increasing the driving force for water loss in the wind-exposed crown side. Leaf physiological changes within the crown help to prevent the decrease of minimum ΨL and thus contribute to the maintenance of homeostasis, assuring the hydraulic integrity of the plant under unfavorable conditions. The responses of leaf traits that contribute to mechanical resistance (leaf mass per area and thickness) differed from those of large physiological traits by exhibiting low phenotypic plasticity. The results of this study help us to understand the unique properties of shrubs which have different hydraulic architecture compared to trees.

  14. Analysis of water hammer-structure interaction in piping system for a loss of coolant accident in primary loop of pressurized water reactor

    International Nuclear Information System (INIS)

    Zhang Xiwen; Yang Jinglong; He Feng; Wang Xuefang

    2000-01-01

    The conventional analysis of water hammer and dynamics response of structure in piping system is divided into two parts, and the interaction between them is neglected. The mechanism of fluid-structure interaction under the double-end break pipe in piping system is analyzed. Using the characteristics method, the numerical simulation of water hammer-structure interaction in piping system is completed based on 14 parameters and 14 partial differential equations of fluid-piping cell. The calculated results for a loss of coolant accident (LOCA) in primary loop of pressurized water reactor show that the waveform and values of pressure and force with time in piping system are different from that of non-interaction between water hammer and structure in piping system, and the former is less than the later

  15. Relations between soil surface roughness, tortuosity, tillage treatments, rainfall intensity and soil and water losses from a red yellow latosol

    Directory of Open Access Journals (Sweden)

    Julieta Bramorski

    2012-08-01

    Full Text Available The soil surface roughness increases water retention and infiltration, reduces the runoff volume and speed and influences soil losses by water erosion. Similarly to other parameters, soil roughness is affected by the tillage system and rainfall volume. Based on these assumptions, the main purpose of this study was to evaluate the effect of tillage treatments on soil surface roughness (RR and tortuosity (T and to investigate the relationship with soil and water losses in a series of simulated rainfall events. The field study was carried out at the experimental station of EMBRAPA Southeastern Cattle Research Center in São Carlos (Fazenda Canchim, in São Paulo State, Brazil. Experimental plots of 33 m² were treated with two tillage practices in three replications, consisting of: untilled (no-tillage soil (NTS and conventionally tilled (plowing plus double disking soil (CTS. Three successive simulated rain tests were applied in 24 h intervals. The three tests consisted of a first rain of 30 mm/h, a second of 30 mm/h and a third rain of 70 mm/h. Immediately after tilling and each rain simulation test, the surface roughness was measured, using a laser profile meter. The tillage treatments induced significant changes in soil surface roughness and tortuosity, demonstrating the importance of the tillage system for the physical surface conditions, favoring water retention and infiltration in the soil. The increase in surface roughness by the tillage treatments was considerably greater than its reduction by rain action. The surface roughness and tortuosity had more influence on the soil volume lost by surface runoff than in the conventional treatment. Possibly, other variables influenced soil and water losses from the no-tillage treatments, e.g., soil type, declivity, slope length, among others not analyzed in this study.

  16. Blood Density Is Nearly Equal to Water Density: A Validation Study of the Gravimetric Method of Measuring Intraoperative Blood Loss.

    Science.gov (United States)

    Vitello, Dominic J; Ripper, Richard M; Fettiplace, Michael R; Weinberg, Guy L; Vitello, Joseph M

    2015-01-01

    Purpose. The gravimetric method of weighing surgical sponges is used to quantify intraoperative blood loss. The dry mass minus the wet mass of the gauze equals the volume of blood lost. This method assumes that the density of blood is equivalent to water (1 gm/mL). This study's purpose was to validate the assumption that the density of blood is equivalent to water and to correlate density with hematocrit. Methods. 50 µL of whole blood was weighed from eighteen rats. A distilled water control was weighed for each blood sample. The averages of the blood and water were compared utilizing a Student's unpaired, one-tailed t-test. The masses of the blood samples and the hematocrits were compared using a linear regression. Results. The average mass of the eighteen blood samples was 0.0489 g and that of the distilled water controls was 0.0492 g. The t-test showed P = 0.2269 and R (2) = 0.03154. The hematocrit values ranged from 24% to 48%. The linear regression R (2) value was 0.1767. Conclusions. The R (2) value comparing the blood and distilled water masses suggests high correlation between the two populations. Linear regression showed the hematocrit was not proportional to the mass of the blood. The study confirmed that the measured density of blood is similar to water.

  17. Clinical symptoms, signs and tests for identification of impending and current water-loss dehydration in older people.

    Science.gov (United States)

    Hooper, Lee; Abdelhamid, Asmaa; Attreed, Natalie J; Campbell, Wayne W; Channell, Adam M; Chassagne, Philippe; Culp, Kennith R; Fletcher, Stephen J; Fortes, Matthew B; Fuller, Nigel; Gaspar, Phyllis M; Gilbert, Daniel J; Heathcote, Adam C; Kafri, Mohannad W; Kajii, Fumiko; Lindner, Gregor; Mack, Gary W; Mentes, Janet C; Merlani, Paolo; Needham, Rowan A; Olde Rikkert, Marcel G M; Perren, Andreas; Powers, James; Ranson, Sheila C; Ritz, Patrick; Rowat, Anne M; Sjöstrand, Fredrik; Smith, Alexandra C; Stookey, Jodi J D; Stotts, Nancy A; Thomas, David R; Vivanti, Angela; Wakefield, Bonnie J; Waldréus, Nana; Walsh, Neil P; Ward, Sean; Potter, John F; Hunter, Paul

    2015-04-30

    There is evidence that water-loss dehydration is common in older people and associated with many causes of morbidity and mortality. However, it is unclear what clinical symptoms, signs and tests may be used to identify early dehydration in older people, so that support can be mobilised to improve hydration before health and well-being are compromised. To determine the diagnostic accuracy of state (one time), minimally invasive clinical symptoms, signs and tests to be used as screening tests for detecting water-loss dehydration in older people by systematically reviewing studies that have measured a reference standard and at least one index test in people aged 65 years and over. Water-loss dehydration was defined primarily as including everyone with either impending or current water-loss dehydration (including all those with serum osmolality ≥ 295 mOsm/kg as being dehydrated). Structured search strategies were developed for MEDLINE (OvidSP), EMBASE (OvidSP), CINAHL, LILACS, DARE and HTA databases (The Cochrane Library), and the International Clinical Trials Registry Platform (ICTRP). Reference lists of included studies and identified relevant reviews were checked. Authors of included studies were contacted for details of further studies. Titles and abstracts were scanned and all potentially relevant studies obtained in full text. Inclusion of full text studies was assessed independently in duplicate, and disagreements resolved by a third author. We wrote to authors of all studies that appeared to have collected data on at least one reference standard and at least one index test, and in at least 10 people aged ≥ 65 years, even where no comparative analysis has been published, requesting original dataset so we could create 2 x 2 tables. Diagnostic accuracy of each test was assessed against the best available reference standard for water-loss dehydration (serum or plasma osmolality cut-off ≥ 295 mOsm/kg, serum osmolarity or weight change) within each study. For

  18. Evaluation of the relation between lipid coat, transepidermal water loss, and skin pH.

    Science.gov (United States)

    Algiert-Zielińska, Barbara; Batory, Mirella; Skubalski, Janusz; Rotsztejn, Helena

    2017-11-01

    The epidermis is an epidermal barrier which accumulates lipid substances and participates in skin moisturizing. An evaluation of the epidermal barrier efficiency can be made, among others, by the measurement of the following values: the lipid coat, the transepidermal water loss (TEWL) index, and pH. The study involved 50 Caucasian, healthy women aged 19-35 years (mean 20.56). Measurements were made using Courage & Khazaka Multi Probe Adapter MPA 580: Tewameter TM 300, pH-Meter PH 905, Sebumeter SM 815. The areas of measurements included forehead, nose, left cheek, right cheek, chin, and thigh. In the T-zone, the lipid coat was in the range between 0 and 270 μg/cm 2 (mean 128 μg/cm 2 ), TEWL between 1 and 55 g/m 2 /h (mean 11.1 g/m 2 /h), and pH 4.0-5.6 (mean 5.39). Lower values of the lipid coat up to 100 μg/cm 2 were accompanied by TEWL greater than 30 g/m 2 /h and less acidic pH of 5.6-9.0. In the U-zone the range of lipid coat was up to 200 μg/cm 2 (mean 65.2 μg/cm 2 ), the skin pH remained 4.0-5.6 (mean 5.47), and TEWL was in the range between 1 and 20 g/m 2 /h (mean 8.7 g/m 2 /h). Lower values of the lipid coat up to 100 μg/cm 2 were accompanied by TEWL between 1 and 20 g/m 2 /h and less acidic pH of 5.6-9.0. High values of the lipid coat between 180 and 200 μg/cm 2 were connected with TEWL of 1-15 g/m 2 /h. On the skin of the thigh, we observed a very thin lipid coat - 35 μg/cm 2 (mean 5.6 μg/cm 2 ), pH (mean 5.37), and TEWL (mean 8.5 g/m 2 /h) were considered by us to be within regular limits. In the T-zone, a thinner lipid coat resulted in relatively high TEWL and pH levels changing toward alkaline. In the U-zone, thinner lipid coat was accompanied by lower TEWL and pH changing toward alkaline. We also observed that lower values of lipid coat up to 100 μg/cm 2 were associated with higher pH values ranging toward the basic character pH 5.6-9.0). © 2017 The International Society of Dermatology.

  19. Effects of a hypothetical loss-of-coolant accident on a Mark I Boiling Water Reactor pressure-suppression system

    International Nuclear Information System (INIS)

    Pitts, J.H.; McCauley, E.W.

    1977-01-01

    A loss-of-coolant accident (LOCA) in a boiling-water-reactor (BWR) power plant has never occurred. However, because this type of accident could be particularly severe, it is used as a principal theoretical basis for design. A series of consistent, versatile, and accurate air-water tests that simulate LOCA conditions has been completed on a 1 / 5 -scale Mark I BWR pressure-suppression system. Results from these tests are used to quantify the vertical-loading function and to study the associated fluid dynamics phenomena. Detailed histories of vertical loads on the wetwell are shown. In particular, variation of hydrodynamic-generated vertical loads with changes in drywell-pressurization rate, downcomer submergence, and the vent-line loss coefficient are established. Initial drywell overpressure, which partially preclears the downcomers of water, substantially reduces the peak vertical loads. Scaling relationships, developed from dimensional analysis and verified by bench-top experiments, allow the 1 / 5 -scale results to be applied to a full-scale BWR power plant. This analysis leads to dimensionless groupings that are invariant. These groupings show that, if water is used as the working fluid, the magnitude of the forces in a scaled facility is reduced by the cube of the scale factor and occurs in a time reduced by the square root of the scale factor

  20. Providing all global energy with wind, water, and solar power, Part II: Reliability, system and transmission costs, and policies

    International Nuclear Information System (INIS)

    Delucchi, Mark A.; Jacobson, Mark Z.

    2011-01-01

    This is Part II of two papers evaluating the feasibility of providing all energy for all purposes (electric power, transportation, and heating/cooling), everywhere in the world, from wind, water, and the sun (WWS). In Part I, we described the prominent renewable energy plans that have been proposed and discussed the characteristics of WWS energy systems, the global demand for and availability of WWS energy, quantities and areas required for WWS infrastructure, and supplies of critical materials. Here, we discuss methods of addressing the variability of WWS energy to ensure that power supply reliably matches demand (including interconnecting geographically dispersed resources, using hydroelectricity, using demand-response management, storing electric power on site, over-sizing peak generation capacity and producing hydrogen with the excess, storing electric power in vehicle batteries, and forecasting weather to project energy supplies), the economics of WWS generation and transmission, the economics of WWS use in transportation, and policy measures needed to enhance the viability of a WWS system. We find that the cost of energy in a 100% WWS will be similar to the cost today. We conclude that barriers to a 100% conversion to WWS power worldwide are primarily social and political, not technological or even economic. - Research highlights: → We evaluate the feasibility of global energy supply from wind, water, and solar energy. → WWS energy can be supplied reliably and economically to all energy-use sectors. → The social cost of WWS energy generally is less than the cost of fossil-fuel energy. → Barriers to 100% WWS power worldwide are socio-political, not techno-economic.

  1. No runoff, no soil loss : soil and water conservation in hedgerow barrier systems

    NARCIS (Netherlands)

    Kiepe, P.

    1995-01-01

    Land degradation by water erosion represents a serious, and fast increasing, environmental threat. Hedgerow barriers control water erosion through the presence of the tree stem and through an increase in infiltration beneath the hedgerow. The infiltration rate beneath hedgerows is 3-8 times

  2. Leakage detection and estimation algorithm for loss reduction in water piping networks

    CSIR Research Space (South Africa)

    Adedeji, KB

    2017-10-01

    Full Text Available the development of efficient algorithms for detecting leakage in water piping networks. Water distribution networks (WDNs) are disperse in nature with numerous number of nodes and branches. Consequently, identifying the segment(s) of the network and the exact...

  3. Hydrophobic-modified nano-cellulose fiber/PLA biodegradable composites for lowering water vapor transmission rate (WVTR) of paper.

    Science.gov (United States)

    Song, Zhaoping; Xiao, Huining; Zhao, Yi

    2014-10-13

    New biodegradable nanocomposites have been successfully prepared by incorporating modified nano-cellulose fibers (NCF) in a biodegradable polylactic acid (PLA) matrix in this work. The hydrophobic-modified NCF was obtained by grafting hydrophobic monomers on NCF to improve the compatibility between NCF and PLA during blending. The resulting NCF/PLA composites were then applied on paper surface via a cast-coating process in an attempt to reduce the water vapor transmission rate (WVTR) of paper. The WVTR tests, conducted under various testing conditions and with different coating weights, demonstrated that the modified NCF/PLA composites coating played a critical role in lowering WVTR of paper. The lowest WVTR value was 34 g/m(2)/d, which was obtained with an addition of 1% of modified NCF to PLA and the composites coating weight at 40 g/m(2) and substantially lower than the control value at 1315 g/m(2)/d. The paper coated with the modified biodegradable composite is promising as green-based packaging materials. Copyright © 2014 Elsevier Ltd. All rights reserved.

  4. Quantification of soil and water losses in an extensive olive orchard catchment in Southern Spain

    Science.gov (United States)

    Rodrigo-Comino, Jesús; Taguas, Encarnación; Seeger, Manuel; Ries, Johannes B.

    2018-01-01

    A sound understanding of erosive processes at different scales can contribute substantially to the design of suitable management strategies. The main aim of this work was to evaluate key factors at the pedon scale that cause soil erosion to occur. To achieve this goal, we quantified infiltration, permeability, soil losses and runoff volumes in a small Southern Spanish catchment cultivated with olive orchards. To assess which factor contributed most to speeding up soil erosion, a Spearman rank coefficient and principal components analysis were carried out. The results confirmed low infiltration values (11.8 mm h-1) in the surface soil layers and high permeability values (24.6 mm h-1) in the sub-surface soil layers, and produced an average soil loss of 19.7 g m-2 and average runoff coefficients of 26.1%. Statistical analyses showed that: i) the generation of runoff was closely correlated with soil loss; and, ii) an increase in the vegetation cover helped reduce soil erosion. In comparison to larger areas such as a catchment, the pedon scale produced lower or similar soil losses and runoff coefficients in rainfall simulation conditions, although the influence of vegetation cover as a control factor was also detected.

  5. Analysis of water hammer in a penstock in the case of valve closure. Part 1: Without pressure losses

    Directory of Open Access Journals (Sweden)

    Hocine HAMMOUM

    2016-04-01

    Full Text Available We develop, in this paper, a method of calculating the water hammer inspired by the graphic construction of Bergeron, which we qualify as analytical method. In helping us of these graphs, we get the relationships that allow calculating the flow rates and pressures along a penstock. The flow of water is carried out by gravity adduction connecting at upstream a storage tank and at downstream a valve. In this first part, we neglect the pressure losses. The study will focus on water hammer-induced by a slow closing of the valve. A practical example will be presented at the end of this work in order to illustrate the exposed method.

  6. Extreme water loss and abiotic O2 buildup on planets throughout the habitable zones of M dwarfs.

    Science.gov (United States)

    Luger, R; Barnes, R

    2015-02-01

    We show that terrestrial planets in the habitable zones of M dwarfs older than ∼1 Gyr could have been in runaway greenhouses for several hundred million years following their formation due to the star's extended pre-main sequence phase, provided they form with abundant surface water. Such prolonged runaway greenhouses can lead to planetary evolution divergent from that of Earth. During this early runaway phase, photolysis of water vapor and hydrogen/oxygen escape to space can lead to the loss of several Earth oceans of water from planets throughout the habitable zone, regardless of whether the escape is energy-limited or diffusion-limited. We find that the amount of water lost scales with the planet mass, since the diffusion-limited hydrogen escape flux is proportional to the planet surface gravity. In addition to undergoing potential desiccation, planets with inefficient oxygen sinks at the surface may build up hundreds to thousands of bar of abiotically produced O2, resulting in potential false positives for life. The amount of O2 that builds up also scales with the planet mass; we find that O2 builds up at a constant rate that is controlled by diffusion: ∼5 bar/Myr on Earth-mass planets and up to ∼25 bar/Myr on super-Earths. As a result, some recently discovered super-Earths in the habitable zone such as GJ 667Cc could have built up as many as 2000 bar of O2 due to the loss of up to 10 Earth oceans of water. The fate of a given planet strongly depends on the extreme ultraviolet flux, the duration of the runaway regime, the initial water content, and the rate at which oxygen is absorbed by the surface. In general, we find that the initial phase of high luminosity may compromise the habitability of many terrestrial planets orbiting low-mass stars.

  7. Cs-134 transfer from water or food to the Ciprinid Tinca tinca Linnaeus: uptake and loss kinetics

    International Nuclear Information System (INIS)

    Corisco, J.A.G.; Carreiro, M.C.V.

    1991-01-01

    Experiments with 134 Cs and the fish Tinca tinca Linnaeus (fam. Cyprinidae), as a part of a more extensive work, concerning a simplified freshwater trophic chain using water from Fratel dam, (at Tejo River), were undertaken. Direct uptake from water, during a period of about 30 days, leads to a kinetics expressed by the power function: CF (t) = 0.58 t 0.781 (t in days), the concentration factor (CF) referred to wet weight. Retention study, showed the existence of two biological half-lives, Tb 1 = 7 days and Tb 2 = 87 days, which might concern respectively, the 134 Cs desorption from the transit organs and the loss of the assimilated isotope from the storage organs. In the accumulation through the food chain, using planktonic crustacean Daphnia magna Straus (Cladocera) as prey, a transfer factor (TF) related to wet weight of both fish and prey, is estimated through the power function: TF (t) = 0.022 t 0.578 (t in days). Finally, the retention study following the food pathway contamination, stresses the existence of one long term component, with half-life Tb = 61 days. The transfer factor kinetics seems to point out to a rather slow process, leading to lower 134 Cs concentration values, than the contamination through the water. The loss of the assimilated 134 Cs, uptaken through both pathways, water or food, is a slow process. The longer biological half-life is very important in Radiological Protection, once it may be attributed to the radionuclide loss from the muscular mass. (author)

  8. Magnitude of Annual Soil Loss from a Hilly Cultivated Slope in Northern Vietnam and Evaluation of Factors Controlling Water Erosion

    International Nuclear Information System (INIS)

    Kurosawa, K.; Hai Do, N.; Nguyen, T.C.; Egashira, K.

    2010-01-01

    A soil erosion experiment was conducted in northern Vietnam over three rainy seasons to clarify the magnitude of soil loss and factors controlling water erosion. The plot had a low (8%) or medium (14.5%) slope with land-cover of cassava or morning glory or being bare. Annual soil loss (177 to 2,361 g/m 2 ) was a tolerable level in all low-slope plots but was not in some medium-slope plots. The effects of slope gradient and seasonal rainfall on the mean daily soil loss of the season were confirmed, but the effect of land-cover was not, owing to the small canopy cover ratio or leaf area index during the season. The very high annual soil loss (>2,200 g/m 2 ) observed in the first year of some medium-slope plots was the site-specific effect from initial land preparation. Since the site-specific effect was large, the preparation must be done carefully on the slope

  9. Loss of deuterium in faecal solids and by sequestration in reindeer: effect on doubly labelled water studies

    Directory of Open Access Journals (Sweden)

    Geir Gotaas

    2000-03-01

    Full Text Available An underlying assumption when estimating total energy expenditure (TEE using doubly labelled water (DLW is that the injected isotopes (lsO and 2H leave the body only in the form of CO, and H20. However, both isotopes have additional routes of loss. We quantified the loss of 2H (i attached to faecal solids and (ii by sequestration into newly synthesised fat in reindeer (Rangifer tarandus tarandus. Estimates of the errors caused by these processes were applied to data from DLW studies with reindeer in summer and in winter. Given the net rate of faecal dry matter output and lipid synthesis in the present study, ignoring both sources of error caused the TEE of reindeer to be underestimated by approximately 5% in winter and approximately 9% in summer. The separate effect of each source of error was evaluated in summer. If ignored, loss of 2H through sequestration alone caused TEE to be underestimated by approximately 3.7%. Similarly, if ignored, loss of 2H attached to faecal solids alone caused TEE to be underestimated by approximately 5.9%.

  10. Steam--water mixing in nuclear reactor safety loss-of-coolant experiments

    International Nuclear Information System (INIS)

    Naff, S.A.; Schwarz, W.F.

    1978-01-01

    Computer models used to predict the response of reactors to hypothesized accidents necessarily incorporate approximating assumptions. To verify the models by comparing predicted and measured responses in test facilities, these assumptions must be confirmed to be realistic. Recent experiments in facilities capable of repeatedly duplicating the transient behavior of a pressurized water reactor undergoing a pipe rupture show that the assumption of complete water-steam mixing during the transient results in the predicted decompression being faster than that observed. Water reactor safety studies currently in progress include programs aimed at the verification of computer models or ''codes'' used to predict reactor system responses to various hypothesized accidents. The approach is to compare code predictions of transients with the actual test transients in experimental facilities. The purpose of this paper is to explain an important instance in which predictions and data are not in complete agreement and to indicate the significance to water reactor safety studies

  11. Economic simplified boiling water reactor (ESBWR) response to an extended station blackout/ loss of all AC power

    International Nuclear Information System (INIS)

    Barrett, A.J.; Marquino, W.

    2013-01-01

    U.S. federal regulations require light water cooled nuclear power plants to cope with Station Blackout for a predetermined amount of time based on design factors for the plant. U.S. regulations define Station Blackout (SBO) as a loss of the offsite electric power system concurrent with turbine trip and unavailability of the onsite emergency AC power system. According to U.S. regulations, typically the coping period for an SBO is 4 hours and can be as long as 16 hours for currently operating BWR plants. Being able to cope with an SBO and loss of all AC power is required by international regulators as well. The U.S. licensing basis for the ESBWR is a coping period of 72 hours for an SBO based on U.S. NRC requirements for passive safety plants. In the event of an extended SBO (viz., greater than 72 hours), the ESBWR response shows that the design is able to cope with the event for at least 7 days without AC electrical power or operator action. ESBWR is a Generation III+ reactor design with an array of passive safety systems. The ESBWR primary success path for mitigation of an SBO event is the Isolation Condenser System (ICS). The ICS is a passive, closed loop, safety system that initiates automatically on a loss of power. Upon Station Blackout or loss of all AC power, the ICS begins removing decay heat from the Reactor Pressure Vessel (RPV) by (i) condensing the steam into water in heat exchangers located in pools of water above the containment, and (ii) transferring the decay heat to the atmosphere. The condensed water is then returned by gravity to cool the reactor again. The ICS alone is capable of maintaining the ESBWR in a safe shutdown condition after an SBO for an extended period. The fuel remains covered throughout the SBO event. The ICS is able to remove decay heat from the RPV for at least 7 days and maintains the reactor in a safe shutdown condition. The water level in the RPV remains well above the top of active fuel for the duration of the SBO event

  12. Research on loss of coolant accident of pressurized-water reactor based on PSO algorithm

    International Nuclear Information System (INIS)

    Ma Jie; Guo Lifeng; Peng Qiao

    2012-01-01

    In order to improve the diagnosis performance of Loss of Coolant Accident (LOCA), based on Back Propagation (BP) algorithm study, a fault diagnosis network is established based on Particle Swarm Optimization (PSO) algorithm in this paper. The PSO algorithm is used to train the weights and the thresholds of neural network, which can conquer part convergence problem of BP algorithm. The test results show that the diagnosis network has higher accuracy of LOCA. (authors)

  13. Behaviour of a pressurized-water reactor nuclear power plant during loss-of-coolant accident

    International Nuclear Information System (INIS)

    Adam, E.; Carl, H.; Kubis, K.

    1979-01-01

    Starting from the foundation of the design basis accident in a PWR-type nuclear power plant - Loss of Coolant Accident -the actual status of the processes to be expected in the reactor are described. Operating behaviour of the heat removal system and efficiency of the safety systems are evaluated. Final considerations are concerned with the overall behaviour of the plant under such conditions. Probable failures, shut down times and possibilities of repair are estimated. (author)

  14. [Coordination effect between vapor water loss through plant stomata and liquid water supply in soil-plant-atmosphere continuum (SPAC): a review].

    Science.gov (United States)

    Liu, Li-Min; Qi, Hua; Luo, Xin-Lan; Zhang, Xuan

    2008-09-01

    Some important phenomena and behaviors concerned with the coordination effect between vapor water loss through plant stomata and liquid water supply in SPAC were discussed in this paper. A large amount of research results showed that plants show isohydric behavior when the plant hydraulic and chemical signals cooperate to promote the stomatal regulation of leaf water potential. The feedback response of stomata to the change of environmental humidity could be used to explain the midday depression of stomatal conductance and photosynthesis under drought condition, and also, to interpret the correlation between stomatal conductance and hydraulic conductance. The feed-forward response of stomata to the change of environmental humidity could be used to explain the hysteresis response of stomatal conductance to leaf-atmosphere vapor pressure deficit. The strategy for getting the most of xylem transport requires the rapid stomatal responses to avoid excess cavitation and the corresponding mechanisms for reversal of cavitation in short time.

  15. Measuring surface-water loss in Honouliuli Stream near the ‘Ewa Shaft, O‘ahu, Hawai‘i

    Science.gov (United States)

    Rosa, Sarah N.

    2017-05-30

    The Honolulu Board of Water Supply is currently concerned with the possibility of bacteria in the pumped water of the ‘Ewa Shaft (State well 3-2202-21). Groundwater from the ‘Ewa Shaft could potentially be used to meet future potable water needs in the ‘Ewa area on the island of O‘ahu. The source of the bacteria in the pumped water is unknown, although previous studies indicate that surface water may be lost to the subsurface near the site. The ‘Ewa Shaft consists of a vertical shaft, started near the south bank of Honouliuli Stream at an altitude of about 161 feet, and two horizontal infiltration tunnels near sea level. The shaft extracts groundwater from near the top of the freshwater lens in the Waipahu-Waiawa aquifer system within the greater Pearl Harbor Aquifer Sector, a designated Water Management Area.The surface-water losses were evaluated with continuous groundwater-level data from the ‘Ewa Shaft and a nearby monitoring well, continuous stream-discharge data from U.S. Geological Survey streamflow-gaging station 16212490 (Honouliuli Stream at H-1 Freeway near Waipahu), and seepage-run measurements in Honouliuli Stream and its tributary. During storms, discharge at the Honouliuli Stream gaging station increases and groundwater levels at ‘Ewa Shaft and a nearby monitoring well also increase. The concurrent increase in water levels at ‘Ewa Shaft and the nearby monitoring well during storms indicates that regional groundwater-level changes related to increased recharge, reduced withdrawals (due to a decrease in demand during periods of rainfall), or both may be occurring; although these data do not preclude the possibility of local recharge from Honouliuli Stream. Discharge measurements from two seepage runs indicate that surface water in the immediate area adjacent to ‘Ewa Shaft infiltrates into the streambed and may later reach the groundwater system developed by the ‘Ewa Shaft. The estimated seepage loss rates in the vicinity of

  16. Axial distribution of deformation in the cladding of pressurized water reactor fuel rods in a loss-of-coolant accident

    International Nuclear Information System (INIS)

    Rose, K.M.; Mann, C.A.; Hindle, E.D.

    1979-01-01

    In the event of a loss-of-coolant accident in a pressurized water reactor, the cladding of the fuel rods would undergo a temperature excursion while being subject to tensile hoop stress. The deformation behavior of 470-mm lengths of Zircaloy-4 fuel cladding has been studied experimentally; under a range of stress levels in the high-alpha range of zirconium (600 to 850 0 C), diametral strains of up to 70% were observed over the greater part of their length. A negative-feedback mechanism is suggested, based on the reduction of secondary creep rate following cooling by enhanced heat loss at swelling areas. An approximate analysis based on this mechanism was found to be in reasonable agreement with the experimental results. A computer modeling code is being developed to predict cladding deformation under realistic conditions

  17. Axial distribution of deformation in the cladding of pressurized water reactor fuel rods in a loss-of-coolant accident

    Energy Technology Data Exchange (ETDEWEB)

    Rose, K.M.; Mann, C.A.; Hindle, E.D.

    1979-12-01

    In the event of a loss-of-coolant accident in a pressurized water reactor, the cladding of the fuel rods would undergo a temperature excursion while being subject to tensile hoop stress. The deformation behavior of 470-mm lengths of Zircaloy-4 fuel cladding has been studied experimentally; under a range of stress levels in the high-alpha range of zirconium (600 to 850/sup 0/C), diametral strains of up to 70% were observed over the greater part of their length. A negative-feedback mechanism is suggested, based on the reduction of secondary creep rate following cooling by enhanced heat loss at swelling areas. An approximate analysis based on this mechanism was found to be in reasonable agreement with the experimental results. A computer modeling code is being developed to predict cladding deformation under realistic conditions.

  18. The effect of pricing level to the loss of welfare costs (case study: Indonesia region II water company)

    Science.gov (United States)

    K, B. Rosalina E. W.; Gravitiani, E.; Raharjo, M.; Mulyaningsih, T.

    2018-03-01

    Climate change makes the water balance composition being unstable, both quality and quantity. As a company which responsible for water management, Regional Drinking Water Company (abbreviated as PDAM) is often unable to solve the problem. Welfare costs are indicators to evaluate the economic efficiency. This study aims to calculate the welfare cost of the people lost due to the price determination of PDAM Indonesia in region II with deadweight loss (DWL) approach, so it can provide information to pricing regulator, pricing decision makers and for coIDRorate management. DWL is a loss of economic efficiency that can occur when equilibrium for a good or a service is not achieved, caused by monopoly pricing of artificial scarcity, an externality, a tax or subsidy, or a binding price ceiling or price floor such as a minimum wage. Results showed that the pricing rules set by PDAM yielded different DWL, depending on margin set by the company DWL PDAM ranges between IDR 260,485.66/M3 to IDR 127,486,709.86/M3 which is actually shared to improve the welfare of customers, other communities, and PDAM itself. Data analysis used PDAM performance in 2015 that have not Good CoIDRorate Governance Management and Efficiency.

  19. Loss of Propiconazole and Its Four Stereoisomers from the Water Phase of Two Soil-Water Slurries as Measured by Capillary Electrophoresis

    Directory of Open Access Journals (Sweden)

    Rebecca D. Miller

    2011-08-01

    Full Text Available Propiconazole is a chiral fungicide used in agriculture for control of many fungal diseases on a variety of crops. This use provides opportunities for pollution of soil and, subsequently, groundwater. The rate of loss of propiconazole from the water phase of two different soil-water slurries spiked with the fungicide at 50 mg/L was followed under aerobic conditions over five months; the t1/2 was 45 and 51 days for the two soil slurries. To accurately assess environmental and human risk, it is necessary to analyze the separate stereoisomers of chiral pollutants, because it is known that for most such pollutants, both biotransformation and toxicity are likely to be stereoselective. Micellar electrokinetic chromatography (MEKC, the mode of capillary electrophoresis used for analysis of neutral chemicals, was used for analysis of the four propiconazole stereoisomers with time in the water phase of the slurries. MEKC resulted in baseline separation of all stereoisomers, while GC-MS using a chiral column gave only partial separation. The four stereoisomers of propiconazole were lost from the aqueous phase of the slurries at experimentally equivalent rates, i.e., there was very little, if any, stereoselectivity. No loss of propiconazole was observed from the autoclaved controls of either soil, indicating that the loss from active samples was most likely caused by aerobic biotansformation, with a possible contribution by sorption to the non-autoclaved active soils. MEKC is a powerful tool for separation of stereoisomers and can be used to study the fate and transformation kinetics of chiral pesticides in water and soil.

  20. Use of the Universal Soil-Loss Equation to determine water erosion with the semi-circular bund water-harvesting technique in the Syrian Steppe

    Directory of Open Access Journals (Sweden)

    Hamdan Al Mahmoud

    2014-05-01

    Full Text Available This research was conducted through the rain season 2009 -2010, in Mehasseh Research Center at (Al Qaryatein, The area is characterized by a hot and dry climate in summer and cold in winter with an annual average rainfall of 114 mm. Three slopes (8%, 6%, 4% were used in semicircular bunds water -harvesting techniques with bunds parallel to the contours lines at flow distance of 18, 12 and 6 m. The bunds were planted with Atriplex Halimus seedlings. Graded metal rulers were planted inside the bunds to determine soil loss and sedimentation associated with the surface runoff, and metallic tanks were placed at the end of the flow paths to determine agricultural soil loss from water runoff. A rain intensity gauge was placed near the experiment site to determine the rainfall intensity that produced runoff. The treatments were done in three replications. The amount of soil erosion (in tons per hectare per year increased with increasing of the slope, the highest recorded value was 38.66 at slope of 8% and the lowest 0.05 at 4% slope. The amount of soil erosion also increased with increasing of water run distance, which was 38.66 T.ha-1.yr-1 at 18 m and 0.05 T.ha-1.yr-1 at 6 m . Bunds with different diameter of water harvesting reduced soil erosion by about 65% at slope of 8%, 55% at 6%, and 46% at 4%. The input parameters of Universal soil-loss equation were found to be suitable for determining soil erosion in this arid and semi-arid region. DOI: http://dx.doi.org/10.3126/ije.v3i2.10499 International Journal of the Environment Vol.3(2 2014: 1-11

  1. Effects of diet and water supply on energy intake and water loss in a mygalomorph spider in a fluctuating environment of the central Andes.

    Science.gov (United States)

    Canals, M; Figueroa, D; Alfaro, C; Kawamoto, T; Torres-Contreras, H; Sabat, P; Veloso, C

    2011-11-01

    The metabolic and water evaporation strategies in spiders may be part of a set of physiological adaptations to tolerate low or unpredictable food availability, buffering spiders against environmental fluctuations such as those of the high mountains of the central Andes. The aim of this study is to analyze experimentally the variations in metabolic rate and the rate of evaporative water with food and/or water restriction in a high mountain mygalomorph spider population (Paraphysa sp.). We found that the low metabolism of this spider was not affected by water restriction, but its metabolism was depressed after 3 weeks of food deprivation. The spider did not show seasonal metabolic changes but it presented seasonal changes in the rate of evaporative water loss at high temperatures. Females with egg sacs reduced their metabolic rate and evaporative water at high temperatures. These findings constitute a set of possible adaptations to a highly fluctuating Mediterranean environment, which is completely covered with snow for many months and then progresses rapidly to a very dry climate with high temperatures. Copyright © 2011 Elsevier Ltd. All rights reserved.

  2. Evaluation of Required Water Sources during Extended Loss of All AC Power for CANDU NPPs

    Energy Technology Data Exchange (ETDEWEB)

    Jeon, Woo Jae; Lee, Kyung Jin; Kim, Min Ki; Kim, Keon Yeop; Park, Da Hee; Oh, Seo Bin [FNC Technology Co., Yongin (Korea, Republic of); Chang, Young Jin; Byun, Choong Seop [KHNP, Daejeon (Korea, Republic of)

    2016-10-15

    Fukushima accident was caused by lasting long hours of Station Black-Out (SBO) triggered from natural disaster. This accident had resulted in the reactor core damage. The purpose of this study is to evaluate the required water sources to maintain hot standby conditions until 72 hours during ELAP situation. The analysis was performed with CATHENA code. CATHENA code has been developed for the best-estimated transient simulation of CANDU plants. This study was carried out to evaluate the strategy to maintain hot standby conditions during ELAP situation in CANDU reactors. In this analysis, water was supplied to SG by MSSV open and by the gravity feed. It can cool the core without damage until the dousing tank depletion. Before dousing tank depletion, the emergency water supply pump was available by emergency power restoration. The pump continuously fed water to SG. So it is expected that the reactor core can be cooled down without damage for 72 hours if water source is enough to feed. This result is useful to make a strategy against SBO including ELAP situation.

  3. Genetic and biochemical analysis reveals linked QTLs determining natural variation for fruit post-harvest water loss in pepper (Capsicum).

    Science.gov (United States)

    Popovsky-Sarid, Sigal; Borovsky, Yelena; Faigenboim, Adi; Parsons, Eugene P; Lohrey, Gregory T; Alkalai-Tuvia, Sharon; Fallik, Elazar; Jenks, Matthew A; Paran, Ilan

    2017-02-01

    Molecular markers linked to QTLs controlling post-harvest fruit water loss in pepper may be utilized to accelerate breeding for improved shelf life and inhibit over-ripening before harvest. Bell pepper (Capsicum annuum L.) is an important vegetable crop world-wide. However, marketing is limited by the relatively short shelf life of the fruit due to water loss and decay that occur during prolonged storage. Towards breeding pepper with reduced fruit post-harvest water loss (PWL), we studied the genetic, physiological and biochemical basis for natural variation of PWL. We performed quantitative trait locus (QTL) mapping of fruit PWL in multiple generations of an interspecific cross of pepper, which resulted in the identification of two linked QTLs on chromosome 10 that control the trait. We further developed near-isogenic lines (NILs) for characterization of the QTL effects. Transcriptome analysis of the NILs allowed the identification of candidate genes associated with fruit PWL-associated traits such as cuticle biosynthesis, cell wall metabolism and fruit ripening. Significant differences in PWL between the NILs in the immature fruit stage, differentially expressed cuticle-associated genes and differences in the content of specific chemical constituents of the fruit cuticle, indicated a likely influence of cuticle composition on the trait. Reduced PWL in the NILs was associated with delayed over-ripening before harvest, low total soluble solids before storage, and reduced fruit softening after storage. Our study enabled a better understanding of the genetic and biological processes controlling natural variation in fruit PWL in pepper. Furthermore, the genetic materials and molecular markers developed in this study may be utilized to breed peppers with improved shelf life and inhibited over-ripening before harvest.

  4. Time-domain numerical computations of electromagnetic fields in cylindrical co-ordinates using the transmission line matrix: evaluation of radiaion losses from a charge bunch passing through a pill-box resonator

    International Nuclear Information System (INIS)

    Sarma, J.; Robson, P.N.

    1979-01-01

    The two dimensional transmission line matrix (TLM) numerical method has been adapted to compute electromagnetic field distributions in cylindrical co-ordinates and it is applied to evaluate the radiation loss from a charge bunch passing through a 'pill-box' resonator. The computer program has been developed to calculate not only the total energy loss to the resonator but also that component of it which exists in the TM 010 mode. The numerically computed results are shown to agree very well with the analytically derived values as found in the literature which, therefore, established the degree of accuracy that is obtained with the TLM method. The particular features of computational simplicity, numerical stability and the inherently time-domain solutions produced by the TLM method are cited as additional, attractive reasons for using this numerical procedure in solving such problems. (Auth.)

  5. Modifications to the steady-state 41-node thermoregulatory model including validation of the respiratory and diffusional water loss equations

    Science.gov (United States)

    1974-01-01

    After the simplified version of the 41-Node Stolwijk Metabolic Man Model was implemented on the Sigma 3 and UNIVAC 1110 computers in batch mode, it became desirable to make certain revisions. First, the availability of time-sharing terminals makes it possible to provide the capability and flexibility of conversational interaction between user and model. Secondly, recent physiological studies show the need to revise certain parameter values contained in the model. Thirdly, it was desired to make quantitative and accurate predictions of evaporative water loss for humans in an orbiting space station. The result of the first phase of this effort are reported.

  6. Preliminary phenomena identification and ranking tables for simplified boiling water reactor Loss-of-Coolant Accident scenarios

    International Nuclear Information System (INIS)

    Kroeger, P.G.; Rohatgi, U.S.; Jo, J.H.; Slovik, G.C.

    1998-04-01

    For three potential Loss-of-Coolant Accident (LOCA) scenarios in the General Electric Simplified Boiling Water Reactors (SBWR) a set of Phenomena Identification and Ranking Tables (PIRT) is presented. The selected LOCA scenarios are typical for the class of small and large breaks generally considered in Safety Analysis Reports. The method used to develop the PIRTs is described. Following is a discussion of the transient scenarios, the PIRTs are presented and discussed in detailed and in summarized form. A procedure for future validation of the PIRTs, to enhance their value, is outlined. 26 refs., 25 figs., 44 tabs

  7. Nonlinear dynamic response analysis in piping system for a loss of coolant accident in primary loop of pressurized water reactor

    International Nuclear Information System (INIS)

    Zhang Xiwen; He Feng; Hao Pengfei; Wang Xuefang

    2000-01-01

    Based on the elaborate force and moment analysis with characteristics method and control-volume integrating method for the piping system of primary loop under pressurized water reactor' loss of coolant accident (LOCA) conditions, the nonlinear dynamic response of this system is calculated by the updated Lagrangian formulation (ADINA code). The piping system and virtual underpinning are specially processed, the move displacement of the broken pipe with time is accurately acquired, which is very important and useful for the design of piping system and virtual underpinning

  8. Isotope and hydrochemical models for evaluation the water loss by evaporation and groundwater flow of dams

    International Nuclear Information System (INIS)

    Santiago, M.F.; Reboucas, A.C.; Frischkorn, H.

    1986-01-01

    Two different approaches are made: an isotope model, based on the observation of the 180/160 ratio of the water, and an hydrochemical model, using the Cl - concentration, are described and applied to determine the evaporation and groundwater flow rates from or to dams. During a period of three years the dams Pereira de Miranda and Caxitore in Pentecostes - Ceara-Brazil (80 Km west of Fortaleza), located in the Precambrian cristalline rock area, were studies. The results show that the models have a good applicability, to estimate the average daily depth of evaporation from free-water surfaces, from nearby porous media or the groundwater inflow or outflow. (author) [pt

  9. Reflooding phase after loss of coolant of an advanced pressurized water reactor with high conversion ratio

    International Nuclear Information System (INIS)

    Schumann, S.

    1984-01-01

    The emergency core cooling behaviour of an advanced pressurized water reactor (APWR) during the reflooding phase of the LOCA with double-ended break is analysed and compared to a common pressurized water reactor (PWR). The code FLUT-BS, its models and correlations are explained in detail and have been verified by numerous PWR-reflood experiments with large parameter range. The influence of core-design on ECC-behaviour as well as the influences of initial and boundary values are examined. The results show the essential differences of ECC-behaviour between PWR and APWR. (orig.) [de

  10. Analytical estimation show low depth-independent water loss due to vapor flux from deep aquifers

    Science.gov (United States)

    Selker, John S.

    2017-06-01

    Recent articles have provided estimates of evaporative flux from water tables in deserts that span 5 orders of magnitude. In this paper, we present an analytical calculation that indicates aquifer vapor flux to be limited to 0.01 mm/yr for sites where there is negligible recharge and the water table is well over 20 m below the surface. This value arises from the geothermal gradient, and therefore, is nearly independent of the actual depth of the aquifer. The value is in agreement with several numerical studies, but is 500 times lower than recently reported experimental values, and 100 times larger than an earlier analytical estimate.

  11. Atomic level study of water-gas shift catalysts via transmission electron microscopy and x-ray spectroscopy

    Science.gov (United States)

    Akatay, Mehmed Cem

    Water-gas shift (WGS), CO + H2O ⇆ CO2 + H2 (DeltaH° = -41 kJ mol -1), is an industrially important reaction for the production of high purity hydrogen. Commercial Cu/ZnO/Al2O3 catalysts are employed to accelerate this reaction, yet these catalysts suffer from certain drawbacks, including costly regeneration processes and sulfur poisoning. Extensive research is focused on developing new catalysts to replace the current technology. Supported noble metals stand out as promising candidates, yet comprise intricate nanostructures complicating the understanding of their working mechanism. In this study, the structure of the supported Pt catalysts is explored by transmission electron microscopy and X-ray spectroscopy. The effect of the supporting phase and the use of secondary metals on the reaction kinetics is investigated. Structural heterogeneities are quantified and correlated with the kinetic descriptors of the catalysts to develop a fundamental understanding of the catalytic mechanism. The effect of the reaction environment on catalyst structure is examined by in-situ techniques. This study benefitted greatly from the use of model catalysts that provide a convenient medium for the atomic level characterization of nanostructures. Based on these studies, Pt supported on iron oxide nano islands deposited on inert spherical alumina exhibited 48 times higher WGS turnover rate (normalized by the total Pt surface area) than Pt supported on bulk iron oxide. The rate of aqueous phase glycerol reforming reaction of Pt supported on multiwall carbon nanotubes (MWCNT) is promoted by co-impregnating with cobalt. The synthesis resulted in a variety of nanostructures among which Pt-Co bimetallic nanoparticles are found to be responsible for the observed promotion. The unprecedented WGS rate of Pt supported on Mo2C is explored by forming Mo 2C patches on top of MWCNTs and the rate promotion is found to be caused by the Pt-Mo bimetallic entities.

  12. Effectiveness of oat and rye cover crops in reducing nitrate losses in drainage water

    Science.gov (United States)

    A significant portion of the NO3 from agricultural fields that contaminates surface waters in the Midwest Corn Belt is transported to streams or rivers by subsurface drainage systems or “tiles”. Previous research has shown that N fertilizer management alone is not sufficient for reducing NO3 concent...

  13. Water holding capacity and evaporative loss from organic bedding materials used in livestock facilities

    Science.gov (United States)

    Physical and chemical characteristics of organic bedding materials determine how well they will absorb and retain moisture and may influence the environment in livestock facilities where bedding is used. The objective of this study was to determine water holding capacity (WHC) and rate of evaporativ...

  14. A two reservoir model to predict Escherichia coli losses to water from pastures grazed by dairy cows.

    Science.gov (United States)

    Muirhead, R W; Monaghan, R M

    2012-04-01

    Animal agriculture has been identified as an important source of diffuse faecal microbial pollution of water. Our current understanding of the losses of faecal microbes from grazed pasture systems is however poor. To help synthesise our current knowledge, a simple two reservoir model was constructed to represent the faecal and environmental sources of Escherichia coli found in a grazed pastoral system. The size of the faecal reservoir was modelled on a daily basis with inputs from grazing animals, and losses due to die-off of E. coli and decomposition of the faecal material. Estimates were made of transport coefficients of E. coli losses from the two reservoirs. The concentration of E. coli measured in overland flow and artificial drainage from grazed plots, used for calibration of the model, showed a significant (Ppasture systems. Research is needed to understand the behaviour and impact of this environmental reservoir. Scenario analysis using the model indicated that rather than manipulating the faecal material itself post defecation, mitigation options should focus on manipulating grazing management. Copyright © 2011 Elsevier Ltd. All rights reserved.

  15. The effects of nutrient losses from agriculture on ground and surface water quality: the position of science in developing indicators for regulation

    NARCIS (Netherlands)

    Schröder, J.J.; Scholefield, D.; Cabral, F.; Hofmans, G.

    2004-01-01

    The magnitude of current nutrient losses from agriculture to ground and surface water calls for effective environmental policy, including the use of regulation. Nutrient loss is experienced in many countries despite differences in the organisation and intensity of agricultural production. However,

  16. Loss of coolant analysis for CIRENE-LATINA heavy water reactor

    International Nuclear Information System (INIS)

    Chiantore, B.; Dubbini, M.; Proto, G.

    1978-01-01

    CIRENE is a heavy-water moderated, boiling water cooled pressure tube reactor. Fuel is natural uranium. A variety of breaks in the primary coolant system have been postulated for the analysis of the CIRENE Latina Plant (now under construction) such as double-end break of inlet header, downcomer, steam line and inlet feeders. The basic tool for analysis is the TILT-N Code which has been purposely developed for simulating the nuclear, thermal and hydrodynamic behaviour of the CIRENE core and associated heat transport system. An extensive full-scale test programme has been carried out by CNEN and CISE which fully confirms the adequacy of the model. The main results of the analysis show that maximum temperatures are far from those leading to significant fuel damage and that adequate core cooling is provided over the whole transient. (author)

  17. Interfacing systems LOCA (loss-of-coolant accidents): Pressurized water reactors

    International Nuclear Information System (INIS)

    Bozoki, G.; Kohut, P.; Fitzpatrick, R.

    1989-02-01

    This report summarizes a study performed by Brookhaven National Laboratory for the Office of Nuclear Regulatory Research, Reactor and Plant Safety Issues Branch, Division of Reactor and Plant Systems, US Nuclear Regulatory Commission. This study was requested by the NRC in order to provide a technical basis for the resolution of Generic Issue 105 ''Interfacing LOCA at LWRs.'' This report deals with pressurized water reactors (PWRs). A parallel report was also accomplished for boiling water reactors. This study focuses on three representative PWRs and extrapolates the plant-specific findings for their generic applicability. In addition, a generic analysis was performed to investigate the cost-benefit aspects of imposing a testing program that would require some minimum level of leak testing of the pressure isolation valves on plants that presently have no such requirements. 28 refs., 31 figs., 64 tabs

  18. Calculation of photon dose for Dalat research reactor in case of loss of reactor tank water

    International Nuclear Information System (INIS)

    Le Vinh Vinh; Huynh Ton Nghiem; Nguyen Kien Cuong

    2007-01-01

    Photon sources of actinides and fission products were estimated by ORIGEN2 code with the modified cross-section library for Dalat research reactor (DRR) using new cross-section generated by WIMS-ANL code. Photon sources of reactor tank water calculated from the experimental data. MCNP4C2 with available non-analog Monte Carlo model and ANSI/ANL-6.1.1-1977 flux-to-dose factors were used for dose estimation. The agreement between calculation results and those of measurements showed that the methods and models used to get photon sources and dose were acceptable. In case the reactor water totally leaks out from the reactor tank, the calculated dose is very high at the top of reactor tank while still low in control room. In the reactor hall, the operation staffs can access for emergency works but with time limits. (author)

  19. Fiscal 1999 basic survey report for promotion of joint implementation. Project for overall loss reduction in Myanmar for thermoelectric power during transmission and distribution; 1999 nendo Myanmar koku karyoku sohaiden denryoku sonshitsu sogo teigen project hokokusho

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-03-01

    With connection to the clean development mechanism (CDM) taken into consideration, a study is made about achieving greenhouse gas reduction in Myanmar through power generation facility heat efficiency improvement and power loss reduction. Taken up in the study are the Shwedaung power plant, the Mann power plant, and the power transmission system in the Mandalay District. The profitability of thermoelectric power facility improvement is calculated using the financial internal rate of return (FIRR), derivable from the cost of thermoelectric power facility improvement and the convenience to be created thereby, and using the opportunity cost in Myanmar. The result is then subjected to a feasibility study. Most effective for CO2 reduction is the addition or installation of advanced compound cycle power generation facilities which are also excellent in heat efficiency and power generation cost. The FIRR of thermoelectric power facility improvement is 9.4-12.8%, which means the effort is worth investment. Measures for decreasing power loss during transmission include the use of higher voltages, laying of new lines, employment of conductors thicker in size, and the installation of phase modifiers. The economic internal rate of return (EIRR) and FIRR are calculated for the study of feasibility. An analysis covering a 10-year period results in a 20.41% EIRR (exceeding the socially accepted discount rate of 10%) and a 17.56% FIRR (exceeding the general loan interest of 15%), which means that there is feasibility. (NEDO)

  20. Simulation of total loss of feed water in ATLAS test facility using SPACE code

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Minhee; Kim, Seyun [Korea Hydro and Nuclear Power Co., Daejeon (Korea, Republic of). Central Research Inst.

    2017-08-15

    A total loss of feedwater (TLOFW) with additional failures in ATLAS test facility was analyzed using SPACE code, which is an advanced thermal-hydraulic system analysis code developed by the Korea nuclear industry. Partial failure of the safety injection pumps (SIPs) and the pilot-operated safety relief valves (POSRVs) of pressurizer were selected as additional failures. In order to assess the capability of SPACE code, partial failure was modeled, and compared with results of OECD-ATLAS A3.1 results. Reasonably good agreement with major thermal-hydraulic parameters was obtained by analyzing the transient behavior. From the results, this indicated that SPACE code has capabilities to design extension conditions, and feed and bleed operation using POSRVs and SIPs were effective for RCS cooling capability during TLOFW.

  1. Frontier between medium and large break loss of coolant accidents of pressurized water reactor

    Science.gov (United States)

    Kim, Taewan

    2017-10-01

    In order to provide the probabilistic safety assessment with more realistic condition to calculate the frequency of the initiating event, a study on the frontier between medium-break and large-break loss-of-coolant-accidents has been performed by using best-estimate thermal hydraulic code, TRACE. A methodology based on the combination of the essential safety features and system parameter has been applied to the Zion nuclear power plant to evaluate the validity of the frontier utilized for the probabilistic safety assessment. The peak cladding temperature has been chosen as a relevant system parameter that represents the system behavior during the transient. The results showed that the frontier should be extended from 6 in. to 10 in. based on the required safety functions and system response.

  2. Loss-of-coolant accident for large pipe breaks in light water reactor plants

    International Nuclear Information System (INIS)

    Keusenhoff, J.

    1980-01-01

    The importance of loss-of-coolant accidents (LOCA) and their control for nuclear reactor safety is explained. Showing the cooling circuits and emergency core cooling systems (ECCS) of both, PWR and BWR, the possible break spectrum and the general sequence of events is discussed. The governing physical phenomena for the different LOCA phases are pointed out in more detail. Special emphasis is taken on rules, regulations and failure criteria for licensing purposes. Analysis methods and codes for both, evaluation and best-estimate model are compared under deterministic and probabilistic approach, respectively. Some insight in present integral and separate effect tests demonstrates the interdependency of analysis and experiment. Results of LOCA analysis and experiments show the present state of the art. (orig.)

  3. 4R Water Quality Impacts: An Assessment and Synthesis of Forty Years of Drainage Nitrogen Losses.

    Science.gov (United States)

    Christianson, L E; Harmel, R D

    2015-11-01

    The intersection of agricultural drainage and nutrient mobility in the environment has led to multiscale water quality concerns. This work reviewed and quantitatively analyzed nearly 1,000 site-years of subsurface tile drainage nitrogen (N) load data to develop a more comprehensive understanding of the impacts of 4R practices (application of the right source of nutrients, at the right rate and time, and in the right place) within drained landscapes across North America. Using drainage data newly compiled in the "Measured Annual Nutrient loads from AGricultural Environments" (MANAGE) database, relationships were developed across N application rates for nitrate N drainage loads and corn ( L.) yields. The lack of significant differences between N application timing or application method was inconsistent with the current emphasis placed on application timing, in particular, as a water quality improvement strategy ( = 0.934 and 0.916, respectively). Broad-scale analyses such as this can help identify major trends for water quality, but accurate implementation of the 4R approach will require site-specific knowledge to balance agronomic and environmental goals. Copyright © by the American Society of Agronomy, Crop Science Society of America, and Soil Science Society of America, Inc.

  4. Effect of water depth on the performance of intelligent computing models in predicting wave transmission of floating pipe breakwater.

    Digital Repository Service at National Institute of Oceanography (India)

    Patil, S.G.; Mandal, S.; Hegde, A.V.

    Understanding the physics of complex system plays an important role in selection of data for training intelligent computing models. Based on the physics of the wave transmission of Horizontally Interlaced Multilayer Moored Floating Pipe Breakwater...

  5. Modeling of the loss of soil by water erosion of the basin of the River V Anniversary Cuyaguateje

    International Nuclear Information System (INIS)

    Alonso, Gustavo R.; Días, Jorge; Ruíz, Maria Elena

    2008-01-01

    The complexity of the processes involved in water erosion of soils has led to widespread use of models with high level of empiricism. However, there are few applications based on models with a considerable physical basis in this field. The purpose of this work is to evaluate the potential of a model of physical basis for estimating soil loss by erosion basin-scale and analyze the behavior of the variables in this model response. The study area was located in the Sub-basin V anniversary, which belongs to the basin of the Cuyaguateje, in the province of Pinar de Rio. You were a database of physical properties of main soils of the basin, the series-temporales of solid spending and runoff measured at River, and rain recorded by a network of rain gauges across the basin. The equation of physical basis used was the sediment transport model (STM), according to Biesemans (2000). As input variables of the model were obtained the following maps: the digital elevation model, accumulative area of drainage, drainage, land use, surface water retention capacity, retention of moisture and hydraulic conductivity of saturation curve. Soil loss was obtained per pixel, and these were correlated with each time series. The results show that the process can be extended to other sub-basins without the need to validate all the variables involved

  6. Down-regulation of POLYGALACTURONASE1 alters firmness, tensile strength and water loss in apple (Malus x domestica) fruit.

    Science.gov (United States)

    Atkinson, Ross G; Sutherland, Paul W; Johnston, Sarah L; Gunaseelan, Kularajathevan; Hallett, Ian C; Mitra, Deepali; Brummell, David A; Schröder, Roswitha; Johnston, Jason W; Schaffer, Robert J

    2012-08-02

    While there is now a significant body of research correlating apple (Malus x domestica) fruit softening with the cell wall hydrolase ENDO-POLYGALACTURONASE1 (PG1), there is currently little knowledge of its physiological effects in planta. This study examined the effect of down regulation of PG1 expression in 'Royal Gala' apples, a cultivar that typically has high levels of PG1, and softens during fruit ripening. PG1-suppressed 'Royal Gala' apples harvested from multiple seasons were firmer than controls after ripening, and intercellular adhesion was higher. Cell wall analyses indicated changes in yield and composition of pectin, and a higher molecular weight distribution of CDTA-soluble pectin. Structural analyses revealed more ruptured cells and free juice in pulled apart sections, suggesting improved integrity of intercellular connections and consequent cell rupture due to failure of the primary cell walls under stress. PG1-suppressed lines also had reduced expansion of cells in the hypodermis of ripe apples, resulting in more densely packed cells in this layer. This change in morphology appears to be linked with reduced transpirational water loss in the fruit. These findings confirm PG1's role in apple fruit softening and suggests that this is achieved in part by reducing cellular adhesion. This is consistent with previous studies carried out in strawberry but not with those performed in tomato. In apple PG1 also appears to influence other fruit texture characters such as juiciness and water loss.

  7. Effect of temperature on incubation period, embryonic mortality, hatch rate, egg water loss and partridge chick weight (Rhynchotus rufescens

    Directory of Open Access Journals (Sweden)

    Nakage ES

    2003-01-01

    Full Text Available The aim of this study was to determine the effects of incubation temperature (34.5; 35.5; 36.5; 37.5 and 38.5ºC, on incubation period, embryonic mortality, hatching rate, water loss and chick weight at hatch, using daily incubation of partridge (Rhynchotus rufescens eggs. The highest hatching percentage was obtained between 35.5 and 36.5ºC. Incubation length and temperature were inversely proportional. Water loss was lower in eggs incubated at low temperatures as compared to high temperatures. There was no difference among incubation temperatures in absolute and relative hatchling weights. Early embryonic mortality increased at low temperatures (36.5ºC. Our results show that, under conditions of daily incubation of eggs in the same incubator, higher hatching rate can be obtained using temperatures between 35.5ºC and 36.5ºC; incubation temperature is inversely proportional to incubation length, and absolute and relative weights of partridge chicks are not affected by incubation temperature.

  8. Electromagnetic field analyses of two-layer power transmission cables consisting of coated conductors with magnetic and non-magnetic substrates and AC losses in their superconductor layers

    International Nuclear Information System (INIS)

    Nakahata, Masaaki; Amemiya, Naoyuki

    2008-01-01

    Two-dimensional electromagnetic field analyses were undertaken using two representative cross sections of two-layer cables consisting of coated conductors with magnetic and non-magnetic substrates. The following two arrangements were used for the coated conductors between the inner and outer layers: (1) tape-on-tape and (2) alternate. The calculated magnetic flux profile around each coated conductor was visualized. In the case of the non-magnetic substrate, the magnetic field to which coated conductors in the outer layer are exposed contains more perpendicular component to the conductor wide face (perpendicular field component) when compared to that in the inner layer. On the other hand, for the tape-on-tape arrangement of coated conductors with a magnetic substrate, the reverse is true. In the case of the alternate arrangement of the coated conductor with a magnetic substrate, the magnetic field to which the coated conductors in the inner and outer layers are exposed experiences a small perpendicular field component. When using a non-magnetic substrate, the AC loss in the superconductor layer of the coated conductors in the two-layer cables is dominated by that in the outer layer, whereas the reverse is true in the case of a magnetic substrate. When comparing the AC losses in superconductor layers of coated conductors with non-magnetic and magnetic substrates in two-layer cables, the latter is larger than the former, but the influence of the magnetism of substrates on AC losses in superconductor layers is not remarkable

  9. Analysis of an accident of local zone control system of 'pressure loss in the compartment water supply reservoir'

    International Nuclear Information System (INIS)

    Catana, A.

    2001-01-01

    This work presents the aftermath of a failure in the Zonal Control System caused by an accident of 'pressure loss in the compartment water supply reservoir' leading to an operational function fault of the liquid zonal control system. Causes for pressure drop may be several, as for instance: simultaneous mechanical fault of the three pumps, class IV total loss of power, a crack of reservoir, etc. Should this accident happens the reactor is shut down automatically by the digital control computer, on the 'ZONE CONTROL SYSTEM FAILURE' setback condition. The analyses were done hypothesizing that the covering gas system is functioning at design parameters and that the only possible accident is the one of pressure loss in supply reservoir. By making use of the software system developed at INR Pitesti, we could make the analysis of the phenomena which take place and thus we could obtain the evolution of the main parameters, namely, neutron and thermohydraulic parameters, as well as the actuating mode of the control and safety systems. Thus, by assuming a pressure drop under 8. 27 bar the 'SETBACK' system is triggered with a final value of the neutron power of 2% FP which can be reached with a power variation rate of 0.00086 decade/sec (- 0.1%/sec). In conclusion, the main parameters evolve as follows: 1. the water level in compartments is 'frozen' at a level at which the pressure in the supply reservoir is 7.3 bar; 2. the mechanical rods are gradually inserted, one bank first and a second one if necessary; 3. the shim rods are fully inserted; 4. the systems of SDS1 and SDS2 scram systems remain unactuated; 5. after 10 minutes from the 'SETBACK' triggering, the neutron power is reduced under 4%; 6. the thermohydraulic parameters of the primary circuit are maintained at normal values; 7. the thermohydraulic parameters of the secondary circuit are maintained at normal values

  10. Comparison of the replication and transmissibility of an infectious laryngotracheitis virus vaccine delivered via eye-drop or drinking-water.

    Science.gov (United States)

    Coppo, Mauricio J C; Devlin, Joanne M; Noormohammadi, Amir H

    2012-01-01

    Live attenuated vaccines have been extensively used to control infectious laryngotracheitis (ILT). Most vaccines are registered/recommended for use via eye-drop although vaccination via drinking-water is commonly used in the field. Drinking-water vaccination has been associated with non-uniform protection. Bird-to-bird passage of chick-embryo-origin (CEO) ILT vaccines has been shown to result in reversion to virulence. The purpose of the present study was to examine the replication and transmission of a commercial CEO infectious laryngotracheitis virus (ILTV) vaccine strain following drinking-water or eye-drop inoculation. Two groups of 10 specific-pathogen-free chickens were each vaccinated with Serva ILTV vaccine strain either via eye-drop or drinking-water. Groups of four or five unvaccinated birds were placed in contact with vaccinated birds at regular intervals. Tracheal swabs were collected every 4 days from vaccinated and in-contact birds to assess viral replication and transmission using quantitative polymerase chain reaction. Compared with eye-drop-vaccinated birds, drinking-water-vaccinated birds showed delayed viral replication but had detectable viral DNA for a longer period of time. Transmission to chickens exposed by contact on day 0 of the experiments was similar in both groups. Birds exposed to ILTV by contact with eye-drop vaccinated birds on days 4, 8, 12 and 16 of the experiment had detectable ILTV for up to 8 days post exposure. ILTV was not detected in chickens that were exposed by contact with drinking-water vaccinated birds on day 12 of the experiment or later. Results from this study provide valuable practical information for the use of ILT vaccine.

  11. Extreme Water Loss and Abiotic O2 Buildup on Planets Throughout the Habitable Zones of M Dwarfs

    Science.gov (United States)

    Barnes, R.

    2015-01-01

    Abstract We show that terrestrial planets in the habitable zones of M dwarfs older than ∼1 Gyr could have been in runaway greenhouses for several hundred million years following their formation due to the star's extended pre-main sequence phase, provided they form with abundant surface water. Such prolonged runaway greenhouses can lead to planetary evolution divergent from that of Earth. During this early runaway phase, photolysis of water vapor and hydrogen/oxygen escape to space can lead to the loss of several Earth oceans of water from planets throughout the habitable zone, regardless of whether the escape is energy-limited or diffusion-limited. We find that the amount of water lost scales with the planet mass, since the diffusion-limited hydrogen escape flux is proportional to the planet surface gravity. In addition to undergoing potential desiccation, planets with inefficient oxygen sinks at the surface may build up hundreds to thousands of bar of abiotically produced O2, resulting in potential false positives for life. The amount of O2 that builds up also scales with the planet mass; we find that O2 builds up at a constant rate that is controlled by diffusion: ∼5 bar/Myr on Earth-mass planets and up to ∼25 bar/Myr on super-Earths. As a result, some recently discovered super-Earths in the habitable zone such as GJ 667Cc could have built up as many as 2000 bar of O2 due to the loss of up to 10 Earth oceans of water. The fate of a given planet strongly depends on the extreme ultraviolet flux, the duration of the runaway regime, the initial water content, and the rate at which oxygen is absorbed by the surface. In general, we find that the initial phase of high luminosity may compromise the habitability of many terrestrial planets orbiting low-mass stars. Key Words: Astrobiology—Biosignatures—Extrasolar terrestrial planets—Habitability—Planetary atmospheres. Astrobiology 15, 119–143. PMID:25629240

  12. Increase in transmission loss of a double panel system by addition of mass inclusions to a poro-elastic layer: A comparison between theory and experiment

    Science.gov (United States)

    Idrisi, Kamal; Johnson, Marty E.; Toso, Alessandro; Carneal, James P.

    2009-06-01

    This paper is concerned with the modeling and optimization of heterogeneous (HG) blankets, which are used in this investigation to reduce the sound transmission through double panel systems. HG blankets consist of poro-elastic media with small embedded masses, which act similarly to a distributed mass-spring-damper-system. HG blankets have shown significant potential to reduce low frequency radiated sound from structures, where traditional poro-elastic materials have little effect. A mathematical model of a double panel system with an acoustic cavity and HG blanket was developed using impedance and mobility methods. The predicted responses of the source and the receiving panel due to a point force are validated with experimental measurements. The presented results indicate that proper tuning of the HG blankets can result in broadband noise reduction below 500 Hz with less than 10% added mass.

  13. Sampling designs and methods for estimating fish-impingement losses at cooling-water intakes

    International Nuclear Information System (INIS)

    Murarka, I.P.; Bodeau, D.J.

    1977-01-01

    Several systems for estimating fish impingement at power plant cooling-water intakes are compared to determine the most statistically efficient sampling designs and methods. Compared to a simple random sampling scheme the stratified systematic random sampling scheme, the systematic random sampling scheme, and the stratified random sampling scheme yield higher efficiencies and better estimators for the parameters in two models of fish impingement as a time-series process. Mathematical results and illustrative examples of the applications of the sampling schemes to simulated and real data are given. Some sampling designs applicable to fish-impingement studies are presented in appendixes

  14. The impact of land use on water loss and soil desiccation in the soil profile

    Science.gov (United States)

    Zhang, Jing; Wang, Li

    2018-02-01

    Farmlands have gradually been replaced by apple orchards in Shaanxi province, China, and there will be a risk of severe soil-water-storage deficit with the increasing age of the apple trees. To provide a theoretical basis for the sustainable development of agriculture and forestry in the Loess Plateau, soil water content in a 19-year-old apple orchard, a 9-year-old apple orchard, a cornfield and a wheat field in the Changwu Tableland was investigated at different depths from January to October 2014. The results showed that: (1) the soil moisture content is different across the soil profile—for the four plots, the soil moisture of the cornfield is the highest, followed by the 9-year-old apple orchard and the wheat field, and the 19-year-old apple orchard has the lowest soil moisture. (2) There are varying degrees of soil desiccation in the four plots: the most serious degree of desiccation is in the 19-year-old apple orchard, followed by the wheat field and the cornfield, with the least severe desiccation occurring in the 9-year-old apple orchard. Farmland should replace apple orchards for an indefinite period while there is an extremely desiccated soil layer in the apple orchard so as to achieve the purpose of sustainable development. It will be necessary to reduce tree densities, and to carry out other research, if development of the economy and ecology of Changwu is to be sustainable.

  15. Analysis of a total loss of pool water accident in MTR-type research reactors

    International Nuclear Information System (INIS)

    Yilmazer, A.; Yavuz, H.

    2004-01-01

    In this study, the transient in which the pool water is lost throughout one or more of the main coolant pipes which are supposed to be broken guillotine-like is investigated for the TR-2 research reactor in Istanbul. The applicability of the methods used for other similar types of research reactors is shown. Decrease of the pool water level until the top of the core, and from the top to the bottom of the core are examined as two successive phases of the accident. Finite difference scheme and integral methods are employed to solve energy equations and the results of both methods are compared. The finite difference solution uses an explicit form for the analysis of the first phase, and a moving boundary approach for the second phase. The integral method is based on the assumption that the temperatures appearing in the energy equations have the same profiles during the transient as the steady state ones. Analyses are done both for nominal and hot channel, and the results of both methods are observed to be in agreement. (orig.)

  16. Analysis of a total loss of pool water accident in MTR-type research reactors

    Energy Technology Data Exchange (ETDEWEB)

    Yilmazer, A. [Hacettepe University, Ankara (Turkey). Nuclear Engineering Department; Yavuz, H. [Istanbul Technical University (Turkey). Energy Institute

    2004-08-01

    In this study, the transient in which the pool water is lost throughout one or more of the main coolant pipes which are supposed to be broken guillotine-like is investigated for the TR-2 research reactor in Istanbul. The applicability of the methods used for other similar types of research reactors is shown. Decrease of the pool water level until the top of the core, and from the top to the bottom of the core are examined as two successive phases of the accident. Finite difference scheme and integral methods are employed to solve energy equations and the results of both methods are compared. The finite difference solution uses an explicit form for the analysis of the first phase, and a moving boundary approach for the second phase. The integral method is based on the assumption that the temperatures appearing in the energy equations have the same profiles during the transient as the steady state ones. Analyses are done both for nominal and hot channel, and the results of both methods are observed to be in agreement. (orig.)

  17. Component evaluation for intersystem loss-of-coolant accidents in advanced light water reactors

    International Nuclear Information System (INIS)

    Ware, A.G.

    1994-07-01

    Using the methodology outlined in NUREG/CR-5603 this report evaluates (on a probabilistic basis) design rules for components in ALWRs that could be subjected to intersystem loss-of-coolant accidents (ISLOCAs). The methodology is intended for piping elements, flange connections, on-line pumps and valves, and heat exchangers. The NRC has directed that the design rules be evaluated for BWR pressures of 7.04 MPa (1025 psig), PWR pressures of 15.4 MPa (2235 psig), and 177 degrees C (350 degrees F), and has established a goal of 90% probability that system rupture will not occur during an ISLOCA event. The results of the calculations in this report show that components designed for a pressure of 0.4 of the reactor coolant system operating pressure will satisfy the NRC survival goal in most cases. Specific recommendations for component strengths for BWR and PWR applications are made in the report. A peer review panel of nationally recognized experts was selected to review and critique the initial results of this program

  18. The hygric hypothesis does not hold water: abolition of discontinuous gas exchange cycles does not affect water loss in the ant Camponotus vicinus.

    Science.gov (United States)

    Lighton, John R B; Turner, Robbin J

    2008-02-01

    The discontinuous gas exchange cycle (DGC) of insects and other tracheate arthropods temporally decouples oxygen uptake and carbon dioxide emission and generates powerful concentration gradients for both gas species between the outside world and the tracheal system. Although the DGC is considered an adaptation to reduce respiratory water loss (RWL) - the "hygric hypothesis" - it is absent from many taxa, including xeric ones. The "chthonic hypothesis" states that the DGC originated as an adaptation to gas exchange in hypoxic and hypercapnic, i.e. underground, environments. If that is the case then the DGC is not the ancestral condition, and its expression is not necessarily a requirement for reducing RWL. Here we report a study of water loss rate in the ant Camponotus vicinus, measured while its DGC was slowly eliminated by gradual hypoxia (hypoxic ramp de-DGCing). Metabolic rate remained constant. The DGC ceased at a mean P(O2) of 8.4 kPa. RWL in the absence of DGCs was not affected until P(O2) declined below 3.9 kPa. Below that value, non-DGC spiracular regulation failed, accompanied by a large increase in RWL. Thus, the spiracular control strategy of the DGC is not required for low RWL, even in animals that normally express the DGC.

  19. ECRH transmission system

    International Nuclear Information System (INIS)

    Tancredi, J.

    1983-01-01

    Hughes, Electron Dynamics Division is developing gyrotrons for ECRH requirements. In the development program, techniques have been evolved for transmission system components. These techniques include over-moded waveguide tapers, high average power windows, and rf water loads for testing

  20. Effectiveness of cuticular transpiration barriers in a desert plant at controlling water loss at high temperatures.

    Science.gov (United States)

    Schuster, Ann-Christin; Burghardt, Markus; Alfarhan, Ahmed; Bueno, Amauri; Hedrich, Rainer; Leide, Jana; Thomas, Jacob; Riederer, Markus

    2016-01-01

    Maintaining the integrity of the cuticular transpiration barrier even at elevated temperatures is of vital importance especially for hot-desert plants. Currently, the temperature dependence of the leaf cuticular water permeability and its relationship with the chemistry of the cuticles are not known for a single desert plant. This study investigates whether (i) the cuticular permeability of a desert plant is lower than that of species from non-desert habitats, (ii) the temperature-dependent increase of permeability is less pronounced than in those species and (iii) whether the susceptibility of the cuticular permeability barrier to high temperatures is related to the amounts or properties of the cutin or the cuticular waxes. We test these questions with Rhazya stricta using the minimum leaf water vapour conductance (gmin) as a proxy for cuticular water permeability. gmin of R. stricta (5.41 × 10(-5) m s(-1) at 25 °C) is in the upper range of all existing data for woody species from various non-desert habitats. At the same time, in R. stricta, the effect of temperature (15-50 °C) on gmin (2.4-fold) is lower than in all other species (up to 12-fold). Rhazya stricta is also special since the temperature dependence of gmin does not become steeper above a certain transition temperature. For identifying the chemical and physical foundation of this phenomenon, the amounts and the compositions of cuticular waxes and cutin were determined. The leaf cuticular wax (251.4 μg cm(-2)) is mainly composed of pentacyclic triterpenoids (85.2% of total wax) while long-chain aliphatics contribute only 3.4%. In comparison with many other species, the triterpenoid-to-cutin ratio of R. stricta (0.63) is high. We propose that the triterpenoids deposited within the cutin matrix restrict the thermal expansion of the polymer and, thus, prevent thermal damage to the highly ordered aliphatic wax barrier even at high temperatures. Published by Oxford University Press on behalf of the

  1. Mass fractionation during transonic escape and implications for loss of water from Mars and Venus

    International Nuclear Information System (INIS)

    Zahnle, K.J.; Kasting, J.F.

    1986-01-01

    Hydrodynamic escape of hydrogen from a planetary atmosphere can remove heavier gases as well as hydrogen, provided that the escape rate is sufficiently large. Analytic approximations for the degree of mass fractionation of a trace species during hydrodynamic escape are compared with accurate numerical solutions for the case of transonic outflow. The analytic approximations are most accurate when the ratio of molecular weights of the heavier and lighter constituents is large so that nonlinear terms in the momentum equation for the heavy constituent become small. The simplest analytic formula is readily generalized to the case where a heavy constituent is also a major species. Application of the generalized formula to hypothetical episodes of hydrodynamic escape from Venus and Mars suggests that both hydrogen and oxygen could have escaped; thus, substantial quantities of water may have been lost without the need to oxidize large amounts of the crust. 29 references

  2. Estimating Snow Water Equivalent with Backscattering at X and Ku Band Based on Absorption Loss

    Directory of Open Access Journals (Sweden)

    Yurong Cui

    2016-06-01

    Full Text Available Snow water equivalent (SWE is a key parameter in the Earth’s energy budget and water cycle. It has been demonstrated that SWE can be retrieved using active microwave remote sensing from space. This necessitates the development of forward models that are capable of simulating the interactions of microwaves and the snow medium. Several proposed models have described snow as a collection of sphere- or ellipsoid-shaped ice particles embedded in air, while the microstructure of snow is, in reality, more complex. Natural snow usually forms a sintered structure following mechanical and thermal metamorphism processes. In this research, the bi-continuous vector radiative transfer (bi-continuous-VRT model, which firstly constructs snow microstructure more similar to real snow and then simulates the snow backscattering signal, is used as the forward model for SWE estimation. Based on this forward model, a parameterization scheme of snow volume backscattering is proposed. A relationship between snow optical thickness and single scattering albedo at X and Ku bands is established by analyzing the database generated from the bi-continuous-VRT model. A cost function with constraints is used to solve effective albedo and optical thickness, while the absorption part of optical thickness is obtained from these two parameters. SWE is estimated after a correction for physical temperature. The estimated SWE is correlated with the measured SWE with an acceptable accuracy. Validation against two-year measurements, using the SnowScat instrument from the Nordic Snow Radar Experiment (NoSREx, shows that the estimated SWE using the presented algorithm has a root mean square error (RMSE of 16.59 mm for the winter of 2009–2010 and 19.70 mm for the winter of 2010–2011.

  3. Developmental plasticity of cutaneous water loss and lipid composition in stratum corneum of desert and mesic nestling house sparrows.

    Science.gov (United States)

    Muñoz-Garcia, Agustí; Williams, Joseph B

    2008-10-07

    Intercellular lipids of the stratum corneum (SC), the outer layer of the epidermis, form a barrier to water vapor diffusion through the skin. Previously, we measured cutaneous water loss (CWL) and lipid composition of the SC of adult house sparrows from two populations, one living in the deserts of Saudi Arabia and another living in mesic Ohio. Adult desert house sparrows had a lower CWL, a lower proportion of free fatty acids, and a higher proportion of ceramides and cerebrosides in the SC compared with mesic sparrows. In this study, we investigated developmental plasticity of CWL and lipid composition of the SC in desert and mesic nestling house sparrows reared in low and high humidity and compared our results with previous work on adults. We measured CWL of nestlings and analyzed the lipid composition of the SC using thin-layer chromatography. We showed that nestling house sparrows from both localities had higher CWL than adults in their natural environment, a result of major modifications of the lipid composition of the SC. The expression of plasticity in CWL seems to be a response to opposed selection pressures, thermoregulation and water conservation, at different life stages, on which regulation of CWL plays a crucial role. Desert nestlings showed a greater degree of plasticity in CWL and lipid composition of the SC than did mesic nestlings, a finding consistent with the idea that organisms exposed to more environmental stress ought to be more plastic than individuals living in more benign environments.

  4. The effect of discontinuous gas exchange on respiratory water loss in grasshoppers (Orthoptera: Acrididae) varies across an aridity gradient.

    Science.gov (United States)

    Huang, Shu-Ping; Talal, Stav; Ayali, Amir; Gefen, Eran

    2015-08-01

    The significance of discontinuous gas-exchange cycles (DGC) in reducing respiratory water loss (RWL) in insects is contentious. Results from single-species studies are equivocal in their support of the classic 'hygric hypothesis' for the evolution of DGC, whereas comparative analyses generally support a link between DGC and water balance. In this study, we investigated DGC prevalence and characteristics and RWL in three grasshopper species (Acrididae, subfamily Pamphaginae) across an aridity gradient in Israel. In order to determine whether DGC contributes to a reduction in RWL, we compared the DGC characteristics and RWL associated with CO2 release (transpiration ratio, i.e. the molar ratio of RWL to CO2 emission rates) among these species. Transpiration ratios of DGC and continuous breathers were also compared intraspecifically. Our data show that DGC characteristics, DGC prevalence and the transpiration ratios correlate well with habitat aridity. The xeric-adapted Tmethis pulchripennis exhibited a significantly shorter burst period and lower transpiration ratio compared with the other two mesic species, Ocneropsis bethlemita and Ocneropsis lividipes. However, DGC resulted in significant water savings compared with continuous exchange in T. pulchripennis only. These unique DGC characteristics for T. pulchripennis were correlated with its significantly higher mass-specific tracheal volume. Our data suggest that the origin of DGC may not be adaptive, but rather that evolved modulation of cycle characteristics confers a fitness advantage under stressful conditions. This modulation may result from morphological and/or physiological modifications. © 2015. Published by The Company of Biologists Ltd.

  5. Effects of Geographic Diversification on Risk Pooling to Mitigate Drought-Related Financial Losses for Water Utilities

    Science.gov (United States)

    Baum, Rachel; Characklis, Gregory W.; Serre, Marc L.

    2018-04-01

    As the costs and regulatory barriers to new water supply development continue to rise, drought management strategies have begun to rely more heavily on temporary conservation measures. While these measures are effective, they often lead to intermittent and unpredictable reductions in revenues that are financially disruptive to water utilities, raising concerns over lower credit ratings and higher rates of borrowing for this capital intensive sector. Consequently, there is growing interest in financial risk management strategies that reduce utility vulnerabilities. This research explores the development of financial index insurance designed to compensate a utility for drought-related losses. The focus is on analyzing candidate hydrologic indices that have the potential to be used by utilities across the US, increasing the potential for risk pooling, which would offer the possibility of both lower risk management costs and more widespread implementation. This work first analyzes drought-related financial risks for 315 publicly operated water utilities across the country and examines the effectiveness of financial contracts based on several indices both in terms of their correlation with utility revenues and their spatial autocorrelation across locations. Hydrologic-based index insurance contracts are then developed and tested over a 120 year period. Results indicate that risk pooling, even under conditions in which droughts are subject to some level of spatial autocorrelation, has the potential to significantly reduce the cost of managing financial risk.

  6. Electric transmission technology

    International Nuclear Information System (INIS)

    Shah, K.R.

    1990-01-01

    Electric transmission technology has matured and can transmit bulk power more reliably and economically than the technology 10 years ago.In 1882, Marcel Depres transmitted 15 kW electric power at 2 kV, using a constant direct current; present transmission voltages have risen to ± 600 kV direct current (DC) and 765 kV alternating current (AC), and it is now possible to transmit bulk electric power at voltages as high as ± 1000 kV DC and 1500 kV AC. Affordable computer systems are now available to optimize transmission reliably. New materials have reduced the bulk of insulation for lines and equipment. New conducting materials and configurations have reduced losses in transmission. Advances in line structures and conductor motion, understanding of flashover characteristics of insulators and air-gaps and electrical performance of lines have resulted in more compact urban transmission lines. (author). 15 refs., 7 tabs., 11 figs

  7. Assumptions used for evaluating the potential radiological consequences of a loss of coolant accident for boiling water reactors - June 1974

    International Nuclear Information System (INIS)

    Anon.

    1974-01-01

    Section 50.34 of 10 CFR Part 50 requires that each applicant for a construction permit or operating license provide an analysis and evaluation of the design and performance of structures, systems, and components of the facility with the objective of assessing the risk to public health and safety resulting from operation of the facility. The design basis loss of coolant accident is one of the postulated accidents used to evaluate the adequacy of these structures, systems, and components with respect to the public health and safety. This guide gives acceptable assumptions that may be used in evaluating the radiological consequences of this accident for a pressurized water reactor. In some cases, unusual site characteristics, plant design features, or other factors may require different assumptions which will be considered on an individual case basis. The Advisory Committee on Reactor Safeguards has been consulted concerning this guide and has concurred in the regulatory position

  8. Loss of ecosystem services due to chronic pollution of forests and surface waters in the Adirondack region (USA).

    Science.gov (United States)

    Beier, Colin M; Caputo, Jesse; Lawrence, Gregory B; Sullivan, Timothy J

    2017-04-15

    Sustaining recent progress in mitigating acid pollution could require lower emissions caps that will give rise to real or perceived tradeoffs between healthy ecosystems and inexpensive energy. Because most impacts of acid rain affect ecosystem functions that are poorly understood by policy-makers and the public, an ecosystem services (ES) framework can help to measure how pollution affects human well-being. Focused on the Adirondack region (USA), a global 'hot-spot' of acid pollution, we measured how the chronic acidification of the region's forests, lakes, and streams has affected the potential economic and cultural benefits they provide to society. We estimated that acid-impaired hardwood forests provide roughly half of the potential benefits of forests on moderate to well-buffered soils - an estimated loss of ∼ $10,000 ha -1 in net present value of wood products, maple syrup, carbon sequestration, and visual quality. Acidic deposition has had only nominal impact - relative to the effects of surficial geology and till depth - on the capacity of Adirondack lakes and streams to provide water suitable for drinking. However, as pH declines in lakes, the estimated value of recreational fishing decreases significantly due to loss of desirable fish such as trout. Hatchery stocking programs have partially offset the pollution-mediated losses of fishery value, most effectively in the pH range 4.8-5.5, but are costly and limited in scope. Although any estimates of the monetary 'damages' of acid rain have significant uncertainties, our findings highlight some of the more tangible economic and cultural benefits of pollution mitigation efforts, which continue to face litigation and political opposition. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  9. Loss of ecosystem services due to chronic pollution of forests and surface waters in the Adirondack region (USA)

    Science.gov (United States)

    Beier, Colin M.; Caputo, Jesse; Lawrence, Gregory B.; Sullivan, Timothy J.

    2017-01-01

    Sustaining recent progress in mitigating acid pollution could require lower emissions caps that will give rise to real or perceived tradeoffs between healthy ecosystems and inexpensive energy. Because most impacts of acid rain affect ecosystem functions that are poorly understood by policy-makers and the public, an ecosystem services (ES) framework can help to measure how pollution affects human well-being. Focused on the Adirondack region (USA), a global ‘hot-spot’ of acid pollution, we measured how the chronic acidification of the region's forests, lakes, and streams has affected the potential economic and cultural benefits they provide to society. We estimated that acid-impaired hardwood forests provide roughly half of the potential benefits of forests on moderate to well-buffered soils – an estimated loss of ∼ $10,000 ha−1 in net present value of wood products, maple syrup, carbon sequestration, and visual quality. Acidic deposition has had only nominal impact – relative to the effects of surficial geology and till depth – on the capacity of Adirondack lakes and streams to provide water suitable for drinking. However, as pH declines in lakes, the estimated value of recreational fishing decreases significantly due to loss of desirable fish such as trout. Hatchery stocking programs have partially offset the pollution-mediated losses of fishery value, most effectively in the pH range 4.8–5.5, but are costly and limited in scope. Although any estimates of the monetary ‘damages’ of acid rain have significant uncertainties, our findings highlight some of the more tangible economic and cultural benefits of pollution mitigation efforts, which continue to face litigation and political opposition.

  10. The effect of increasing water temperatures on Schistosoma mansoni transmission and Biomphalaria pfeifferi population dynamics: an agent-based modelling study.

    Directory of Open Access Journals (Sweden)

    Nicky McCreesh

    Full Text Available There is increasing interest in the control and elimination of schistosomiasis. Little is known, however, about the likely effects of increasing water-body temperatures on transmission.We have developed an agent-based model of the temperature-sensitive stages of the Schistosoma and intermediate host snail life-cycles, parameterised using data from S. mansoni and Biomphalaria pfeifferi laboratory and field-based observations. Infection risk is calculated as the number of cercariae in the model, adjusted for their probability of causing infection.The number of snails in the model is approximately constant between 15-31°C. Outside this range, snail numbers drop sharply, and the snail population cannot survive outside the range 14-32°C. Mean snail generation time decreases with increasing temperature from 176 days at 14°C to 46 days at 26°C. Human infection risk is highest between 16-18°C and 1pm and 6-10pm in calm water, and 20-25°C and 12-4pm in flowing water. Infection risk increases sharply when temperatures increase above the minimum necessary for sustained transmission.The model suggests that, in areas where S. mansoni is already endemic, warming of the water at transmission sites will have differential effects on both snails and parasites depending on abiotic properties of the water-body. Snail generation times will decrease in most areas, meaning that snail populations will recover faster from natural population reductions and from snail-control efforts. We suggest a link between the ecological properties of transmission sites and infection risk which could significantly affect the outcomes of interventions designed to alter water contact behaviour--proposing that such interventions are more likely to reduce infection levels at river locations than lakes, where infection risk remains high for longer. In cooler areas where snails are currently found, increasing temperatures may significantly increase infection risk, potentially leading

  11. Down-regulation of POLYGALACTURONASE1 alters firmness, tensile strength and water loss in apple (Malus x domestica fruit

    Directory of Open Access Journals (Sweden)

    Atkinson Ross G

    2012-08-01

    Full Text Available Abstract Background While there is now a significant body of research correlating apple (Malus x domestica fruit softening with the cell wall hydrolase ENDO-POLYGALACTURONASE1 (PG1, there is currently little knowledge of its physiological effects in planta. This study examined the effect of down regulation of PG1 expression in ‘Royal Gala’ apples, a cultivar that typically has high levels of PG1, and softens during fruit ripening. Results PG1-suppressed ‘Royal Gala’ apples harvested from multiple seasons were firmer than controls after ripening, and intercellular adhesion was higher. Cell wall analyses indicated changes in yield and composition of pectin, and a higher molecular weight distribution of CDTA-soluble pectin. Structural analyses revealed more ruptured cells and free juice in pulled apart sections, suggesting improved integrity of intercellular connections and consequent cell rupture due to failure of the primary cell walls under stress. PG1-suppressed lines also had reduced expansion of cells in the hypodermis of ripe apples, resulting in more densely packed cells in this layer. This change in morphology appears to be linked with reduced transpirational water loss in the fruit. Conclusions These findings confirm PG1’s role in apple fruit softening and suggests that this is achieved in part by reducing cellular adhesion. This is consistent with previous studies carried out in strawberry but not with those performed in tomato. In apple PG1 also appears to influence other fruit texture characters such as juiciness and water loss.

  12. Nitrogen losses and greenhouse gas emissions under different N and water management in a subtropical double-season rice cropping system.

    Science.gov (United States)

    Liang, Kaiming; Zhong, Xuhua; Huang, Nongrong; Lampayan, Rubenito M; Liu, Yanzhuo; Pan, Junfeng; Peng, Bilin; Hu, Xiangyu; Fu, Youqiang

    2017-12-31

    Nitrogen non-point pollution and greenhouse gas (GHG) emission are major challenges in rice production. This study examined options for both economic and environmental sustainability through optimizing water and N management. Field experiments were conducted to examine the crop yields, N use efficiency (NUE), greenhouse gas emissions, N losses under different N and water management. There were four treatments: zero N input with farmer's water management (N0), farmer's N and water management (FP), optimized N management with farmer's water management (OPT N ) and optimized N management with alternate wetting and drying irrigation (OPT N +AWD). Grain yields in OPT N and OPT N +AWD treatments increased by 13.0-17.3% compared with FP. Ammonia volatilization (AV) was the primary pathway for N loss for all treatments and accounted for over 50% of the total losses. N losses mainly occurred before mid-tillering. N losses through AV, leaching and surface runoff in OPT N were reduced by 18.9-51.6% compared with FP. OPT N +AWD further reduced N losses from surface runoff and leaching by 39.1% and 6.2% in early rice season, and by 46.7% and 23.5% in late rice season, respectively, compared with OPT N . The CH 4 emissions in OPT N +AWD were 20.4-45.4% lower than in OPT N and FP. Total global warming potential of CH 4 and N 2 O was the lowest in OPT N +AWD. On-farm comparison confirmed that N loss through runoff in OPT N +AWD was reduced by over 40% as compared with FP. OPT N and OPT N +AWD significantly increased grain yield by 6.7-13.9%. These results indicated that optimizing water and N management can be a simple and effective approach for enhancing yield with reduced environmental footprints. Copyright © 2017. Published by Elsevier B.V.

  13. Neuroglial Transmission

    DEFF Research Database (Denmark)

    Gundersen, Vidar; Storm-Mathisen, Jon; Bergersen, Linda Hildegard

    2015-01-01

    as a signaling substance recently shown to act on specific lactate receptors in the brain. Complementing neurotransmission at a synapse, neuroglial transmission often implies diffusion of the transmitter over a longer distance and concurs with the concept of volume transmission. Transmission from glia modulates...... synaptic neurotransmission based on energetic and other local conditions in a volume of tissue surrounding the individual synapse. Neuroglial transmission appears to contribute significantly to brain functions such as memory, as well as to prevalent neuropathologies....

  14. Corona helps curb losses

    Energy Technology Data Exchange (ETDEWEB)

    Laasonen, M.; Lahtinen, M.; Lustre, L.

    1996-11-01

    The greatest power losses in electricity transmission arise through a phenomenon called load losses. Corona losses caused by the surface discharge of electricity also constitute a considerable cost item. IVS, the nationwide network company, is investigating corona- induced losses, and has also commissioned similar research from IVO International, the Technical Research Centre of Finland (VTT) and from Tampere University of Technology. The research work strives to gain more in-depth knowledge on the phenomenon of frosting and its impact on corona losses. The correct prediction of frost helps reduce corona losses, while also cutting costs considerably. (orig.)

  15. Domestic transmission routes of pathogens: the problem of in-house contamination of drinking water during storage in developing countries

    DEFF Research Database (Denmark)

    Jensen, Peter Kjaer; Ensink, Jeroen H J; Jayasinghe, Gayathri

    2002-01-01

    Even if drinking water of poor rural communities is obtained from a 'safe' source, it can become contaminated during storage in the house. To investigate the relative importance of this domestic domain contamination, a 5-week intervention study was conducted. Sixty-seven households in Punjab......, Pakistan, were provided with new water storage containers (pitchers): 33 received a traditional wide-necked pitcher normally used in the area and the remaining 34 households received a narrow-necked water storage pitcher, preventing direct hand contact with the water. Results showed that the domestic...... domain contamination with indicator bacteria is important only when the water source is relatively clean, i.e. contains less than 100 Escherichia coli per 100 ml of water. When the number of E. coli in the water source is above this value, interventions to prevent the domestic contamination would have...

  16. Accurate and stable equal-pressure measurements of water vapor transmission rate reaching the 10-6 g m-2 day-1 range

    Science.gov (United States)

    Nakano, Yoichiro; Yanase, Takashi; Nagahama, Taro; Yoshida, Hajime; Shimada, Toshihiro

    2016-10-01

    The water vapor transmission rate (WVTR) of a gas barrier coating is a critically important parameter for flexible organic device packaging, but its accurate measurement without mechanical stress to ultrathin films has been a significant challenge in instrumental analysis. At the current stage, no reliable results have been reported in the range of 10-6 g m-2 day-1 that is required for organic light emitting diodes (OLEDs). In this article, we describe a solution for this difficult, but important measurement, involving enhanced sensitivity by a cold trap, stabilized temperature system, pumped sealing and calibration by a standard conductance element.

  17. Effects on weight loss in adults of replacing diet beverages with water during a hypoenergetic diet: a randomized, 24-wk clinical trial.

    Science.gov (United States)

    Madjd, Ameneh; Taylor, Moira A; Delavari, Alireza; Malekzadeh, Reza; Macdonald, Ian A; Farshchi, Hamid R

    2015-12-01

    Obese people believe that drinking diet beverages (DBs) may be a simple strategy to achieve weight loss. However, nutritionists advise drinking water when attempting to lose weight. It is unclear how important drinking water instead of DBs is during a weight-loss program. In this study, we compared the effect on weight loss of either replacing DBs with water or continuing to consume DBs in adults during a 24-wk weight-loss program. Overweight and obese women [n = 89; body mass index (BMI; in kg/m(2)): 27-40; age: 18-50 y] who usually consumed DBs in their diet were asked to either substitute water for DBs (water group) or continue drinking DBs 5 times/wk after their lunch for 24 wk (DB group) while on a weight-loss program. Sixty-two participants (71%) completed the trial (32 in the DB group, 30 in the water group). Baseline variables were not statistically significantly different between groups. A statistically significant reduction in anthropometric measurements and statistically significant improvements in cardiometabolic risk characteristics were observed over 24 wk in both groups. Compared with the DB group, the water group had a greater decrease in weight (mean ± SD: water: -8.8 ± 1.9 kg; DBs: -7.6 ± 2.1 kg; P = 0.015, time × group), fasting insulin (mean ± SD: water: -2.84 ± 0.77 mU/L; DBs: -1.78 ± 1.25 mU/L, P water: -0.097 ± 0.049; DBs: -0.057 ± 0.042, P water: -1.02 ± 0.25 mmol/L; DBs: -0.72 ± 0.27 mmol/L; P fasting plasma glucose, and lipid profiles within both groups over 24 wk. Replacement of DBs with water after the main meal may lead to greater weight reduction during a weight-loss program. It may also offer clinical benefits to improve insulin resistance. This trial was registered at www.irct.ir/ as IRCT201402177754N5. © 2015 American Society for Nutrition.

  18. Soil and water losses in eucalyptus plantation and natural forest and determination of the USLE factors at a pilot sub-basin in Rio Grande do Sul, Brazil

    Directory of Open Access Journals (Sweden)

    Bárbara Pereira Christofaro Silva

    Full Text Available ABSTRACT Monitoring water erosion and the factors that control soil and water loss are essential for soil conservation planning. The objective of this study was to evaluate soil and water losses by water erosion under natural rainfall in eucalyptus plantations established in 2001 (EF2, and 2004 (EF1, native forest (NF and bare soil (BS, during the period of 2007 to 2012; and to determine the USLE factors: rain erosivity (R, erodibility (K of a Red Argisol and the cover-management factor (C for EF1, EF2 and NF at a pilot sub-basin, in Eldorado do Sul, RS, Brazil. The R factor was estimated by the EI30 index, using rainfall data from a gauging station located at the sub-basin. The soil and water losses were monitored in erosion plots, providing consistent data for the estimation of the K and C factors. The sub-basin presented an average erosivity of 4,228.52 MJ mm ha-1 h-1 yr-1. The average annual soil losses em EF1 and EF2 (0.81 e 0.12 Mg ha-1 year-1, respectively were below of the limit of tolerance, 12.9 Mg ha-1 year-1. The percentage values of water loss relating to the total rainfall decreased annually, approaching the values observed at the NF. From the 5th year on after the implantation of the eucalyptus systems, soil losses values were similar to the ones from NF. The erodibility of the Red Argisol was of 0.0026 Mg ha h ha-1 MJ-1mm-1 and the C factor presented values of 0.121, 0.016 and 0.015 for EF1, EF2 and NF, respectively.

  19. A regional assessment of the cost and effectiveness of mitigation measures for reducing nutrient losses to water and greenhouse gas emissions to air from pastoral farms.

    Science.gov (United States)

    Vibart, Ronaldo; Vogeler, Iris; Dennis, Samuel; Kaye-Blake, William; Monaghan, Ross; Burggraaf, Vicki; Beautrais, Josef; Mackay, Alec

    2015-06-01

    Using a novel approach that links geospatial land resource information with individual farm-scale simulation, we conducted a regional assessment of nitrogen (N) and phosphorous (P) losses to water and greenhouse gas (GHG) emissions to air from the predominant mix of pastoral industries in Southland, New Zealand. An evaluation of the cost-effectiveness of several nutrient loss mitigation strategies applied at the farm-scale, set primarily for reducing N and P losses and grouped by capital cost and potential ease of adoption, followed an initial baseline assessment. Grouped nutrient loss mitigation strategies were applied on an additive basis on the assumption of full adoption, and were broadly identified as 'improved nutrient management' (M1), 'improved animal productivity' (M2), and 'restricted grazing' (M3). Estimated annual nitrate-N leaching losses occurring under representative baseline sheep and beef (cattle) farms, and representative baseline dairy farms for the region were 10 ± 2 and 32 ± 6 kg N/ha (mean ± standard deviation), respectively. Both sheep and beef and dairy farms were responsive to N leaching loss mitigation strategies in M1, at a low cost per kg N-loss mitigated. Only dairy farms were responsive to N leaching loss abatement from adopting M2, at no additional cost per kg N-loss mitigated. Dairy farms were also responsive to N leaching loss abatement from adopting M3, but this reduction came at a greater cost per kg N-loss mitigated. Only dairy farms were responsive to P-loss mitigation strategies, in particular by adopting M1. Only dairy farms were responsive to GHG abatement; greater abatement was achieved by the most intensified dairy farm system simulated. Overall, M1 provided for high levels of regional scale N- and P-loss abatement at a low cost per farm without affecting overall farm production, M2 provided additional N-loss abatement but only marginal P-loss abatement, whereas M3 provided the greatest N-loss abatement, but

  20. Identification of hydrogen and deuterium at the surface of water ice by reflection electron energy loss spectroscopy

    International Nuclear Information System (INIS)

    Yubero, F.; Toekesi, K.

    2009-01-01

    Complete text of publication follows. The study of elastically backscattered electrons from surfaces by reflection electron energy loss spectroscopy (REELS) has been recently recommended as an alternative technique to quantify the H content at the surface of a-C:H and polymer samples. This analysis is based on the fact that the energy loss of the incident electrons due to the recoil effect depends on the atomic mass of the particular atom present at the surface. The observed difference in recoil energies between H and O atoms (about 2 eV for 1.5 keV primary electrons) can be easily measured with standard electron spectrometers used in surface analysis. In this paper we go one step forward to explore if, with the same experimental approach, it is possible to differentiate between hydrogen and deuterium (D) in the surface region of a sample. This capability could be important for technological fields such as surface functionalization, where it is desired to distinguish between H and D at surfaces after interaction with labeled compounds. We have chosen normal and deuterated water as test labeled compounds because this polar molecule is of key importance in numerous surface reactions. It has been shown that H and D can be easily distinguished at the surface of water ice [4] using standard REELS measurements with 1000 - 1650 eV primary-electron energies, i.e., a surface analytical technique. Differences in recoil energies of the O - H and O - D atom pairs present in H 2 O and D 2 O have been found to agree with MC simulations (see Fig.1). There are many possible applications of H and D detection by REELS. Among many others, this study opens the possibility of nondestructive studies of deuterium-labeled atoms present or adsorbed on surfaces. For example, studies of H incorporation into a polymer or carbonbased surface after plasma activation with gas mixtures with several labeled molecules containing H atoms. Acknowledgements F.Y. thanks the Spanish Ministry of Science

  1. Transmission issues in Alberta

    International Nuclear Information System (INIS)

    Levson, D.

    2002-01-01

    This paper outlined the major issues and concerns facing users of the transmission system in Alberta. They include congestion management issues that make investors uncertain about power generation. It is necessary to know the difference between which transmission price signals will be faced by low cost cogeneration at Fort McMurray and Cold Lake coal-fired generation near Edmonton compared to combined cycle gas generation near Calgary. Import and export policy tariffs are another concern. Most new generation opportunities in Alberta require access to export markets, but transmission facilities for export need policy support and appropriate tariffs. It was noted that the past actions of Alberta's Transmission Administrator and balancing pool may be distorting market signals for ancillary service markets, and that loss studies and calculations need upgrading

  2. Study on Erosion Factors Affecting Kuroboku Soil Loss I. Water Permeability of Stratified Soil and Slope Gradient

    OpenAIRE

    田熊, 勝利; 猪迫, 耕二; 中原 恒,

    2005-01-01

    The authors examined the factors of bed soil affecting the loss of surface soil and the effects of these factors on the extent of the soil loss. They conducted a multivariate analysis using actual measurement value at a laboratory erosion experiment. They also conducted a simulation of erosion in soil loss using the bed soil factors. Soil loss quantity is dependent on the coefficient of permeability of bed soil; the steeper the latter is, the more the former increases. Lateral soil scattering...

  3. Soil phosphorus loss in tile drainage water from long-term conventional- and non-tillage soils of Ontario with and without compost addition.

    Science.gov (United States)

    Zhang, T Q; Tan, C S; Wang, Y T; Ma, B L; Welacky, T

    2017-02-15

    Recent ascertainment of tile drainage a predominant pathway of soil phosphorus (P) loss, along with the rise in concentration of soluble P in the Lake Erie, has led to a need to re-examine the impacts of agricultural practices. A three-year on-farm study was conducted to assess P loss in tile drainage water under long-term conventional- (CT) and non-tillage (NT) as influenced by yard waste leaf compost (LC) application in a Brookston clay loam soil. The effects of LC addition on soil P loss in tile drainage water varied depending on P forms and tillage systems. Under CT, dissolved reactive P (DRP) loss with LC addition over the study period was 765g P ha -1 , 2.9 times higher than CT without LC application, due to both a 50% increase in tile drainage flow volume and a 165% increase in DRP concentration. Under NT, DRP loss in tile drainage water with LC addition was 1447gPha -1 , 5.3 times greater than that for NT without LC application; this was solely caused by a 564% increase in DRP concentration. However, particulate P loads in tile drainage water with LC application remained unchanged, relative to non-LC application, regardless of tillage systems. Consequently, LC addition led to an increase in total P loads in tile drainage water by 57 and 69% under CT and NT, respectively. The results indicate that LC application may become an environmental concern due to increased DRP loss, particularly under NT. Crown Copyright © 2016. Published by Elsevier B.V. All rights reserved.

  4. Measurement of transepidermal water loss (TEWL) in cats with experimental skin barrier dysfunction using a closed chamber system.

    Science.gov (United States)

    Momota, Yutaka; Shimada, Kenichiro; Gin, Azusa; Matsubara, Takako; Azakami, Daigo; Ishioka, Katsumi; Nakamura, Yuka; Sako, Toshinori

    2016-10-01

    A closed chamber evaporimeter is suitable for measuring transepidermal water loss (TEWL) in cats because of the compact device size, tolerance to sudden movement and short measuring time. TEWL is a representative parameter for skin barrier dysfunction, which is one of the clinical signs of atopic dermatitis in humans and dogs. Measurement of feline TEWL has been reported, but applicability of this parameter has not been validated. The aims of this study were to determine if tape stripping is a valid experimental model in cats for studying TEWL and to determine if a closed chambered system is a suitable measurement tool for cats. Ten clinically normal cats. In order to evaluate variation of the measured values, TEWL was measured at the right and left side of the three clipped regions (axillae, lateral thigh and groin). Subsequently, TEWL was measured using sequential tape stripping of the stratum corneum as a model of acute barrier disruption. The variations between both sides of the three regions showed no significant difference. Sequential tape stripping was associated with increasing values for TEWL. Feline TEWL was shown to reflect changes in the skin barrier in an experimental model using a closed chamber system and has the potential for evaluating skin barrier function in cats with skin diseases. © 2016 ESVD and ACVD.

  5. Radiological consequence analyses of loss of coolant accidents of various break sizes of Pressurized Heavy Water Reactor

    International Nuclear Information System (INIS)

    Sanyasi Rao, V.V.S.; Hari Prasad, M.; Ghosh, A.K.

    2010-01-01

    For any advanced technology, it is essential to ensure that the consequences associated with the accident sequences arising, if any, from the operation of the plant are as low as possible and certainly below the guidelines/limits set by the regulatory bodies. Nuclear power is no exception to this. In this paper consequences of the events arising from Loss of Coolant Accident (LOCA) sequences in Pressurized Heavy Water Reactor (PHWR), are analysed. The sequences correspond to different break sizes of LOCA followed by the operation or otherwise of Emergency Core Cooling System (ECCS). Operation or otherwise of the containment safety systems has also been considered. It has been found that there are no releases to the environment when ECCS is available. The releases, when ECCS is not available, arise from the slack and the ground. The radionuclides considered include noble gases, iodine, and cesium. The hourly meteorological parameters (wind speed, wind direction, precipitation and stability category), considered for this study, correspond to those of Kakrapar site. The consequences evaluated are the thyroid dose and the bone marrow dose received by a person located at various distances from the release point. Isodose curves are generated. From these evaluations, it has been found that the doses are very low. The complementary cumulative frequency distributions (CCFD) for thyroid and bone marrow doses have also been presented for the cases analysed. (author)

  6. A novel continuous colour mapping approach for visualization of facial skin hydration and transepidermal water loss for four ethnic groups.

    Science.gov (United States)

    Voegeli, R; Rawlings, A V; Seroul, P; Summers, B

    2015-12-01

    The aim of this exploratory study was to develop a novel colour mapping approach to visualize and interpret the complexity of facial skin hydration and barrier properties of four ethnic groups (Caucasians, Indians, Chinese and Black Africans) living in Pretoria, South Africa. We measured transepidermal water loss (TEWL) and skin capacitance on 30 pre-defined sites on the forehead, cheek, jaw and eye areas of sixteen women (four per ethnic group) and took digital images of their faces. Continuous colour maps were generated by interpolating between each measured value and superimposing the values on the digital images. The complexity of facial skin hydration and skin barrier properties is revealed by these measurements and visualized by the continuous colour maps of the digital images. Overall, the Caucasian subjects had the better barrier properties followed by the Black African subjects, Chinese subjects and Indian subjects. Nevertheless, the two more darkly pigmented ethnic groups had superior skin hydration properties. Subtle differences were seen when examining the different facial sites. There exists remarkable skin capacitance and TEWL gradients within short distances on selected areas of the face. These gradients are distinctive in the different ethnic groups. In contrast to other reports, we found that darkly pigmented skin does not always have a superior barrier function and differences in skin hydration values are complex on the different parts of the face among the different ethnic groups. © 2015 Society of Cosmetic Scientists and the Société Française de Cosmétologie.

  7. Comparison of numerical and experimental results on flow rate and friction losses in water outflow from extended pipelines

    International Nuclear Information System (INIS)

    Makukhin, A.A.; Fisenko, V.V.; Kolykhanov, V.N.

    1985-01-01

    Results are presented of numerical calculation and experimental determinaion of the flow rate and friction losses during boiling-up water flow motion in extended pipelines at critical outflow regime with account of compressibility of heat-transferring medium. The difference of the calculation model proposed is in the fact that the presence of a finite length pipeline portion is implied where the Mach number (M) remains equal to 1 at a continuously varying flow rate and the sound velocity varying from its thermodynamical equilibrium value inside the channel to the non-equilibrium one at the exit. At that the deceleration pressure along this portion remains constant, and the M=1 condition is maintained automatically due to a constant flow rate. Analysis of numerical experiment has shown that the new scheme of heat transfer by critical two-phase flow is more efficient than that by one-phase flow within the 0.5 to 8 MPa range of initial pressures at a 0-50 K subcooling as a result of a decrease in the head of transfering pumps and a reduction in the pipeline pressure. Experiments carried out show good agreement with the calclation data

  8. Transmission issues

    International Nuclear Information System (INIS)

    Bradford, J.; Wilson, L.; Thon, S.; Millar, N.

    2005-01-01

    This session on transmission issues focused on the role that transmission plays in electricity markets and the importance of getting the market structure right in terms of generation divestiture with buy back contracts, demand side responsive programs, transmission upgrades and long term contracts. The difficul