WorldWideScience

Sample records for water leak detection

  1. Mobile Sensor Networks for Leak and Backflow Detection in Water Distribution Systems

    KAUST Repository

    Suresh, M. Agumbe

    2014-05-01

    Leak and backflow detection are essential aspects of Water Distribution System (WDS) monitoring. Most existing solutions for leak/backflow detection in WDSs focus on the placement of expensive static sensors located strategically. In contrast to these, we propose a solution whereby mobile sensors (i.e., their movement aided only by the inherent water flow in the system) detect leaks/backflow. Information about the leaks/backflow is collected from the sensors either by physically capturing them, or through wireless communication. Specifically, we propose models to maximize leak/backflow detection given a cost constraint (a limit on the number of sensors). Through extensive simulations, we demonstrate the superior performance of our proposed solution when compared with the state of the art solutions (e.g., algorithms/protocols and analysis).

  2. Chlorofluorocarbon leak detection technology

    Energy Technology Data Exchange (ETDEWEB)

    Munday, E.B.

    1990-12-01

    There are about 590 large coolant systems located at the Portsmouth Gaseous Diffusion Plant (PORTS) and the Paducah Gaseous Diffusion Plant (PGDP) leaking nearly 800,000 lb of R-114 refrigerant annually (1989 estimate). A program is now under way to reduce the leakage to 325,000 lb/year -- an average loss of 551 lb/year (0.063 lb/h) per coolant system, some of which are as large as 800 ft. This report investigates leak detection technologies that can be used to locate leaks in the coolant systems. Included are descriptions, minimum leak detection rate levels, advantages, disadvantages, and vendor information on the following technologies: bubbling solutions; colorimetric leak testing; dyes; halogen leak detectors (coronea discharge detectors; halide torch detectors, and heated anode detectors); laser imaging; mass spectroscopy; organic vapor analyzers; odorants; pressure decay methods; solid-state electrolytic-cell gas sensors; thermal conductivity leak detectors; and ultrasonic leak detectors.

  3. Water Pipeline Monitoring and Leak Detection using Flow Liquid Meter Sensor

    Science.gov (United States)

    Rahmat, R. F.; Satria, I. S.; Siregar, B.; Budiarto, R.

    2017-04-01

    Water distribution is generally installed through underground pipes. Monitoring the underground water pipelines is more difficult than monitoring the water pipelines located on the ground in open space. This situation will cause a permanent loss if there is a disturbance in the pipeline such as leakage. Leaks in pipes can be caused by several factors, such as the pipe’s age, improper installation, and natural disasters. Therefore, a solution is required to detect and to determine the location of the damage when there is a leak. The detection of the leak location will use fluid mechanics and kinematics physics based on harness water flow rate data obtained using flow liquid meter sensor and Arduino UNO as a microcontroller. The results show that the proposed method is able to work stably to determine the location of the leak which has a maximum distance of 2 metres, and it’s able to determine the leak location as close as possible with flow rate about 10 litters per minute.

  4. Leak detection aid

    Science.gov (United States)

    Steeper, Timothy J.

    1989-02-01

    A leak detection apparatus and method for detecting leaks across an O-ring sealing a flanged surface to a mating surface is an improvement in a flanged surface comprising a shallow groove following O-ring in communication with an entrance and exit port intersecting the shallow groove for injecting and withdrawing, respectively, a leak detection fluid, such as helium. A small quantity of helium injected into the entrance port will flow to the shallow groove, past the O-ring and to the exit port.

  5. SmartPipes: Smart Wireless Sensor Networks for Leak Detection in Water Pipelines

    Directory of Open Access Journals (Sweden)

    Ali M. Sadeghioon

    2014-02-01

    Full Text Available Asset monitoring, specifically infrastructure monitoring such as water distribution pipelines, is becoming increasingly critical for utility owners who face new challenges due to an aging network. In the UK alone, during the period of 2009–2010, approximately 3281 mega litres (106 of water were wasted due to failure or leaks in water pipelines. Various techniques can be used for the monitoring of water distribution networks. This paper presents the design, development and testing of a smart wireless sensor network for leak detection in water pipelines, based on the measurement of relative indirect pressure changes in plastic pipes. Power consumption of the sensor nodes is minimised to 2.2 mW based on one measurement every 6 h in order to prolong the lifetime of the network and increase the sensor nodes’ compatibility with current levels of power available by energy harvesting methods and long life batteries. A novel pressure sensing method is investigated for its performance and capabilities by both laboratory and field trials. The sensors were capable of measuring pressure changes due to leaks. These pressure profiles can also be used to locate the leaks.

  6. Sensors for Fluid Leak Detection

    Directory of Open Access Journals (Sweden)

    Gonzalo Pajares Martinsanz

    2015-02-01

    Full Text Available Fluid leak detection represents a problem that has attracted the interest of researchers, but not exclusively because in industries and services leaks are frequently common. Indeed, in water or gas supplies, chemical or thermal plants, sea-lines or cooling/heating systems leakage rates can cause important economic losses and sometimes, what it is more relevant, environmental pollution with human, animal or plant lives at risk. This last issue has led to increased national and international regulations with different degrees of severity regarding environmental conservation.[...

  7. Aspects of leak detection

    Energy Technology Data Exchange (ETDEWEB)

    Chivers, T.C. [Berkeley Technology Centre, Glos (United Kingdom)

    1997-04-01

    A requirement of a Leak before Break safety case is that the leakage from the through wall crack be detected prior to any growth leading to unacceptable failure. This paper sets out to review some recent developments in this field. It does not set out to be a comprehensive guide to all of the methods available. The discussion concentrates on acoustic emission and how the techniques can be qualified and deployed on operational plant.

  8. Leak Detection in Water-Filled Small-Diameter Polyethylene Pipes by Means of Acoustic Emission Measurements

    Directory of Open Access Journals (Sweden)

    Alberto Martini

    2016-12-01

    Full Text Available The implementation of effective strategies to manage leaks represents an essential goal for all utilities involved with drinking water supply in order to reduce water losses affecting urban distribution networks. This study concerns the early detection of leaks occurring in small-diameter customers’ connections to water supply networks. An experimental campaign was carried out in a test bed to investigate the sensitivity of Acoustic Emission (AE monitoring to water leaks. Damages were artificially induced on a polyethylene pipe (length 28 m, outer diameter 32 mm at different distances from an AE transducer. Measurements were performed in both unburied and buried pipe conditions. The analysis permitted the identification of a clear correlation between three monitored parameters (namely total Hits, Cumulative Counts and Cumulative Amplitude and the characteristics of the examined leaks.

  9. Leak detection/verification

    Energy Technology Data Exchange (ETDEWEB)

    Krhounek, V.; Zdarek, J.; Pecinka, L. [Nuclear Research Institute, Rez (Czech Republic)

    1997-04-01

    Loss of coolant accident (LOCA) experiments performed as part of a Leak Before Break (LBB) analysis are very briefly summarized. The aim of these experiments was to postulate the leak rates of the coolant. Through-wall cracks were introduced into pipes by fatigue cycling and hydraulically loaded in a test device. Measurements included coolant pressure and temperature, quantity of leaked coolant, displacement of a specimen, and acoustic emission. Small cracks were plugged with particles in the coolant during testing. It is believed that plugging will have no effect in cracks with leak rates above 35 liters per minute. The leak rate safety margin of 10 is sufficient for cracks in which the leak rate is more than 5 liters per minute.

  10. Leak detection capability in CANDU reactors

    Energy Technology Data Exchange (ETDEWEB)

    Azer, N.; Barber, D.H.; Boucher, P.J. [and others

    1997-04-01

    This paper addresses the moisture leak detection capability of Ontario Hydro CANDU reactors which has been demonstrated by performing tests on the reactor. The tests confirmed the response of the annulus gas system (AGS) to the presence of moisture injected to simulate a pressure tube leak and also confirmed the dew point response assumed in leak before break assessments. The tests were performed on Bruce A Unit 4 by injecting known and controlled rates of heavy water vapor. To avoid condensation during test conditions, the amount of moisture which could be injected was small (2-3.5 g/hr). The test response demonstrated that the AGS is capable of detecting and annunciating small leaks. Thus confidence is provided that it would alarm for a growing pressure tube leak where the leak rate is expected to increase to kg/hr rapidly. The measured dew point response was close to that predicted by analysis.

  11. Hermetic Seal Leak Detection Apparatus

    Science.gov (United States)

    Kelley, Anthony R. (Inventor)

    2013-01-01

    The present invention is a hermetic seal leak detection apparatus, which can be used to test for hermetic seal leaks in instruments and containers. A vacuum tight chamber is created around the unit being tested to minimize gas space outside of the hermetic seal. A vacuum inducing device is then used to increase the gas chamber volume inside the device, so that a slight vacuum is pulled on the unit being tested. The pressure in the unit being tested will stabilize. If the stabilized pressure reads close to a known good seal calibration, there is not a leak in the seal. If the stabilized pressure reads closer to a known bad seal calibration value, there is a leak in the seal. The speed of the plunger can be varied and by evaluating the resulting pressure change rates and final values, the leak rate/size can be accurately calculated.

  12. Probabilistic pipe fracture evaluations for leak-rate-detection applications

    Energy Technology Data Exchange (ETDEWEB)

    Rahman, S.; Ghadiali, N.; Paul, D.; Wilkowski, G. [Battelle, Columbus, OH (United States)

    1995-04-01

    Regulatory Guide 1.45, {open_quotes}Reactor Coolant Pressure Boundary Leakage Detection Systems,{close_quotes} was published by the U.S. Nuclear Regulatory Commission (NRC) in May 1973, and provides guidance on leak detection methods and system requirements for Light Water Reactors. Additionally, leak detection limits are specified in plant Technical Specifications and are different for Boiling Water Reactors (BWRs) and Pressurized Water Reactors (PWRs). These leak detection limits are also used in leak-before-break evaluations performed in accordance with Draft Standard Review Plan, Section 3.6.3, {open_quotes}Leak Before Break Evaluation Procedures{close_quotes} where a margin of 10 on the leak detection limit is used in determining the crack size considered in subsequent fracture analyses. This study was requested by the NRC to: (1) evaluate the conditional failure probability for BWR and PWR piping for pipes that were leaking at the allowable leak detection limit, and (2) evaluate the margin of 10 to determine if it was unnecessarily large. A probabilistic approach was undertaken to conduct fracture evaluations of circumferentially cracked pipes for leak-rate-detection applications. Sixteen nuclear piping systems in BWR and PWR plants were analyzed to evaluate conditional failure probability and effects of crack-morphology variability on the current margins used in leak rate detection for leak-before-break.

  13. Hydrogen Leak Detection Sensor Database

    Science.gov (United States)

    Baker, Barton D.

    2010-01-01

    This slide presentation reviews the characteristics of the Hydrogen Sensor database. The database is the result of NASA's continuing interest in and improvement of its ability to detect and assess gas leaks in space applications. The database specifics and a snapshot of an entry in the database are reviewed. Attempts were made to determine the applicability of each of the 65 sensors for ground and/or vehicle use.

  14. Assessment of Current Inservice Inspection and Leak Monitoring Practices for Detecting Materials Degradation in Light Water Reactors

    Energy Technology Data Exchange (ETDEWEB)

    Anderson, Michael T. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Simonen, Fredric A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Muscara, Joseph [US Nuclear Regulatory Commission (NRC), Rockville, MD (United States); Doctor, Steven R. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Kupperman, David S. [Argonne National Lab. (ANL), Argonne, IL (United States)

    2016-09-01

    An assessment was performed to determine the effectiveness of existing inservice inspection (ISI) and leak monitoring techniques, and recommend improvements, as necessary, to the programs as currently performed for light water reactor (LWR) components. Information from nuclear power plant (NPP) aging studies and from the U. S. Nuclear Regulatory Commission’s Generic Aging Lessons Learned (GALL) report (NUREG-1801) was used to identify components that have already experienced, or are expected to experience, degradation. This report provides a discussion of the key aspects and parameters that constitute an effective ISI program and a discussion of the basis and background against which the effectiveness of the ISI and leak monitoring programs for timely detection of degradation was evaluated. Tables based on the GALL components were used to systematically guide the process, and table columns were included that contained the ISI requirements and effectiveness assessment. The information in the tables was analyzed using histograms to reduce the data and help identify any trends. The analysis shows that the overall effectiveness of the ISI programs is very similar for both boiling water reactors (BWRs) and pressurized water reactors (PWRs). The evaluations conducted as part of this research showed that many ISI programs are not effective at detecting degradation before its extent reached 75% of the component wall thickness. This work should be considered as an assessment of NDE practices at this time; however, industry and regulatory activities are currently underway that will impact future effectiveness assessments. A number of actions have been identified to improve the current ISI programs so that degradation can be more reliably detected.

  15. Three-dimensional inversion of CSEM data: Water leak detection using a small-loop EM method

    Science.gov (United States)

    Noh, Kyubo; Chung, Yonghyun; Seol, Soon Jee; Byun, Joongmoo; Uchida, Toshihiro

    2014-03-01

    Electromagnetic (EM) data sets were acquired using ground-based small-loop electromagnetic (EM) sensors over an artificially constructed sandy ground in Tsukuba, Japan, for three conditions of water saturation. The research aim was to evaluate the imaging capability of the geophysical method for detecting a water leak. Because the sensitivity analysis showed a considerable three-dimensional (3D) distribution of sensitivity around the source-receiver location, 3D inversion was applied to the field data sets. We used an accurate 3D controlled-source electromagnetic (CSEM) inversion algorithm, which adopted an edge-based finite element method as a forward scheme. To obtain the best inversion strategy for our field data and for the selection of the optimal regularization method, 3D inversion was applied to synthetic data sets prior to the inversion of the field data; the synthetic data sets were based on synthetic resistivity models used to simulate the three water-saturation phases of the real test site. Based on the results of sensitivity analysis, different regularization methods were systematically tested and the inversion results were qualitatively analyzed. For our monitoring scenario, the best performance was achieved by combining spatially varying regularization parameters, structural constraints, and the reference model method. The reference model parameters were derived from the less ill-posed model, instead of the main target model, which allowed for more accurate imaging of the main region of interest. This optimal inversion strategy was applied to the test-site field data. The water leak was successfully visualized by small-loop EM data, with systematic application of a priori information as constraints.

  16. New role for communication fibre optic cables in water utility for leak detection on main water pipeline

    Directory of Open Access Journals (Sweden)

    Graovac Radojica M.

    2015-01-01

    Full Text Available During construction of main water pipeline it is usual practice to lay fibre optic communication cable along water pipe. This cable is one of the up to date communication media which is used for the connection purposes of water control SCADA equipment as well as for establishing of telephone communication between water utility plants. By developing of new electronic equipment known as DTS (Distributed Temperature Sensing and DAS (Distributed Acoustic Sensing equipment it has been opened the possibility, with this equipment and by utilizing of dedicated optical fibres of optical fibre communication cable as a sensor, to detect leakage point by temperature monitoring or monitoring of acoustic changes along water pipeline (as detection of temperature change of soil at leakage point or detection of acoustic change at leakage point.

  17. Leak Detection for Potable Water Lines at Fort Hood: Final Report on Project AR-F-313 for FY05

    Science.gov (United States)

    2007-06-01

    Conservation Systems Xmic, was used at Fort Hood. This instrument consists of a battery pow- ered control console, a “ground microphone” sensor, and headphones ...of magnification. In addition, borrowed pipe lo- cation equipment (see Figure 2) allowed a pipeline’s route to be traced by inducing an RF carrier ... headphones . This type of sensor can detect sounds coming through the ground and can be used to find the exact spot along the pipeline where the leak

  18. Multichannel leak detection system for electrochemical etching

    Energy Technology Data Exchange (ETDEWEB)

    Muhammed, R.; Abu-Jarad, F.; Al-Jarallah, M.I. (King Fahd Univ. for Petroleum and Minerals, Dhahran (Saudi Arabia))

    1988-01-01

    A multichannel leak detection system has been developed to detect any chemical leak during the electrochemical etching process. It gives an audible and a visible warning when there is a leak at any part of the system. This greatly helps in isolating the defective sample quickly. It can be removed during operation, while the etching process continues on other samples. The circuit is built from standard integrated circuits and has its own power supply. Provisions have been made to connect this system to the computer for recording date, time and location of the leaky unetched samples. (author).

  19. Laser Schlieren System Detects Sounds Of Leaks

    Science.gov (United States)

    Shakkottai, Parthasarathy P.; Alwar, A. Vijayaragavan

    1990-01-01

    Hostile environments monitored safely and noninvasively. Modified laser schlieren system acts as microphone to detect sounds of leaks remotely. Sensitive to acoustical frequencies above audible range and especially suited for monitoring leaks of high-pressure steam from boilers or chemical vapors from processing equipment. Does not require placement of delicate equipment in harsh environment monitored, and no contact needed with boiler or other unit being monitored. Detects sound waves via variation of index of refraction of air at acoustical frequencies. Used to monitor sound frequencies beyond range of human hearing.

  20. On the acoustic filtering of the pipe and sensor in a buried plastic water pipe and its effect on leak detection: an experimental investigation.

    Science.gov (United States)

    Almeida, Fabrício; Brennan, Michael; Joseph, Phillip; Whitfield, Stuart; Dray, Simon; Paschoalini, Amarildo

    2014-03-20

    Acoustic techniques have been used for many years to find and locate leaks in buried water distribution systems. Hydrophones and accelerometers are typically used as sensors. Although geophones could be used as well, they are not generally used for leak detection. A simple acoustic model of the pipe and the sensors has been proposed previously by some of the authors of this paper, and their model was used to explain some of the features observed in measurements. However, simultaneous measurements of a leak using all three sensor-types in controlled conditions for plastic pipes has not been reported to-date and hence they have not yet been compared directly. This paper fills that gap in knowledge. A set of measurements was made on a bespoke buried plastic water distribution pipe test rig to validate the previously reported analytical model. There is qualitative agreement between the experimental results and the model predictions in terms of the differing filtering properties of the pipe-sensor systems. A quality measure for the data is also presented, which is the ratio of the bandwidth over which the analysis is carried out divided by the centre frequency of this bandwidth. Based on this metric, the accelerometer was found to be the best sensor to use for the test rig described in this paper. However, for a system in which the distance between the sensors is large or the attenuation factor of the system is high, then it would be advantageous to use hydrophones, even though they are invasive sensors.

  1. Hydrocarbon Leak Detection Sensor Project

    Data.gov (United States)

    National Aeronautics and Space Administration — FTT is proposing the development of a sensor to detect the presence of hydrocarbons in turbopump Inter-Propellant Seals (IPS). The purpose of the IPS is to prevent...

  2. On the Acoustic Filtering of the Pipe and Sensor in a Buried Plastic Water Pipe and its Effect on Leak Detection: An Experimental Investigation

    Directory of Open Access Journals (Sweden)

    Fabrício Almeida

    2014-03-01

    Full Text Available Acoustic techniques have been used for many years to find and locate leaks in buried water distribution systems. Hydrophones and accelerometers are typically used as sensors. Although geophones could be used as well, they are not generally used for leak detection. A simple acoustic model of the pipe and the sensors has been proposed previously by some of the authors of this paper, and their model was used to explain some of the features observed in measurements. However, simultaneous measurements of a leak using all three sensor-types in controlled conditions for plastic pipes has not been reported to-date and hence they have not yet been compared directly. This paper fills that gap in knowledge. A set of measurements was made on a bespoke buried plastic water distribution pipe test rig to validate the previously reported analytical model. There is qualitative agreement between the experimental results and the model predictions in terms of the differing filtering properties of the pipe-sensor systems. A quality measure for the data is also presented, which is the ratio of the bandwidth over which the analysis is carried out divided by the centre frequency of this bandwidth. Based on this metric, the accelerometer was found to be the best sensor to use for the test rig described in this paper. However, for a system in which the distance between the sensors is large or the attenuation factor of the system is high, then it would be advantageous to use hydrophones, even though they are invasive sensors.

  3. Warming barium sulfate improves esophageal leak detection in pig model.

    Science.gov (United States)

    Raman, Vignesh; MacGlaflin, Caitlyn E; Moodie, Karen L; Kaiser, Larry R; Erkmen, Cherie P

    2015-12-01

    Barium esophagograms have poor sensitivity in detecting leaks. We hypothesized that heating barium would decrease viscosity, facilitate extravasation, and enhance its sensitivity in detecting esophageal leaks. We characterized the viscosity of barium at increasing temperatures. We measured the radiopacity of barium at 25°C and 50°C. We determined the smallest diameter defect in esophagus that barium can detect by perforating a porcine esophageal segment with angiocatheters of various diameters, injecting barium at 25°C, and observing extravasation of contrast. We repeated this with barium heated to 30°C, 40°C, 50°C, and 70°C. To determine the ability of barium to detect a staple line leak, we perforated a stapled esophageal segment by air insufflation, injected barium at different temperatures, and monitored extravasation. We used Visipaque, a water-soluble contrast agent, for comparison in all experiments. The viscosity of barium decreased with increasing temperature. The radiopacity of barium did not change with increasing temperature and was higher than that of Visipaque (P barium at 25°C to 1.3 mm at 40°C and 1.1 mm with Visipaque (P barium at 25°C to 80% (P = 0.02) with barium at 40°C. There was no significant difference in sensitivity between barium at 40°C and Visipaque. Barium warmed to 40°C offers the best sensitivity of esophageal leak detection without compromising radiopacity. Barium at 40°C may be the optimum choice for swallow study to detect esophageal leaks. Copyright © 2015 Elsevier Inc. All rights reserved.

  4. 1999 Leak Detection and Monitoring and Mitigation Strategy Update

    Energy Technology Data Exchange (ETDEWEB)

    OHL, P.C.

    1999-09-23

    This document is a complete revision of WHC-SD-WM-ES-378, Rev 1. This update includes recent developments in Leak Detection, Leak Monitoring, and Leak Mitigation technologies, as well as, recent developments in single-shell tank retrieval technologies. In addition, a single-shell tank retrieval release protection strategy is presented.

  5. A novel multi-scale adaptive sampling-based approach for energy saving in leak detection for WSN-based water pipelines

    Science.gov (United States)

    Saqib, Najam us; Faizan Mysorewala, Muhammad; Cheded, Lahouari

    2017-12-01

    In this paper, we propose a novel monitoring strategy for a wireless sensor networks (WSNs)-based water pipeline network. Our strategy uses a multi-pronged approach to reduce energy consumption based on the use of two types of vibration sensors and pressure sensors, all having different energy levels, and a hierarchical adaptive sampling mechanism to determine the sampling frequency. The sampling rate of the sensors is adjusted according to the bandwidth of the vibration signal being monitored by using a wavelet-based adaptive thresholding scheme that calculates the new sampling frequency for the following cycle. In this multimodal sensing scheme, the duty-cycling approach is used for all sensors to reduce the sampling instances, such that the high-energy, high-precision (HE-HP) vibration sensors have low duty cycles, and the low-energy, low-precision (LE-LP) vibration sensors have high duty cycles. The low duty-cycling (HE-HP) vibration sensor adjusts the sampling frequency of the high duty-cycling (LE-LP) vibration sensor. The simulated test bed considered here consists of a water pipeline network which uses pressure and vibration sensors, with the latter having different energy consumptions and precision levels, at various locations in the network. This is all the more useful for energy conservation for extended monitoring. It is shown that by using the novel features of our proposed scheme, a significant reduction in energy consumption is achieved and the leak is effectively detected by the sensor node that is closest to it. Finally, both the total energy consumed by monitoring as well as the time to detect the leak by a WSN node are computed, and show the superiority of our proposed hierarchical adaptive sampling algorithm over a non-adaptive sampling approach.

  6. Fluid pipeline leak detection and location with miniature RF tags

    Energy Technology Data Exchange (ETDEWEB)

    McIntyre, Timothy J.

    2017-05-16

    Sensors locate troublesome leaks in pipes or conduits that carry a flowing medium. These sensors, through tailored physical and geometric properties, preferentially seek conduit leaks or breaches due to flow streaming. The sensors can be queried via transceivers outside the conduit or located and interrogated inside by submersible unmanned vehicle to identify and characterize the nature of a leak. The sensors can be functionalized with other capabilities for additional leak and pipeline characterization if needed. Sensors can be recovered from a conduit flow stream and reused for future leak detection activities.

  7. Detection and location of leaks in district heating steam systems: Survey and review of current technology and practices

    Energy Technology Data Exchange (ETDEWEB)

    Kupperman, D.S.; Raptis, A.C.; Lanham, R.N.

    1992-03-01

    This report presents the results of a survey undertaken to identify and characterize current practices for detecting and locating leaks in district heating systems, particular steam systems. Currently used technology and practices are reviewed. In addition, the survey was used to gather information that may be important for the application of acoustic leak detection. A few examples of attempts to locate leaks in steam and hot water pipes by correlation of acoustic signals generated by the leaks are also discussed.

  8. Leaks in the internal water supply piping systems

    Directory of Open Access Journals (Sweden)

    Orlov Evgeniy Vladimirovich

    2015-03-01

    Full Text Available Great water losses in the internal plumbing of a building lead to the waste of money for a fence, purification and supply of water volumes in excess. This does not support the concept of water conservation and resource saving lying today in the basis of any building’s construction having plumbing. Leakage means unplanned of water losses systems in domestic water supply systems (hot or cold as a result of impaired integrity, complicating the operation of a system and leading to high costs of repair and equipment restoration. A large number of leaks occur in old buildings, where the regulatory service life of pipelines has come to an end, and the scheduled repair for some reason has not been conducted. Steel pipelines are used in the systems without any protection from corrosion and they get out of order. Leakages in new houses are also not uncommon. They usually occur as a result of low-quality adjustment of the system by workers. It also important to note the absence of certain skills of plumbers, who don’t conduct the inspections of in-house systems in time. Sometimes also the residents themselves forget to keep their pipeline systems and water fittings in their apartment in good condition. Plumbers are not systematically invited for preventive examinations to detect possible leaks in the domestic plumbing. The amount of unproductive losses increases while simultaneous use of valve tenants, and at the increase of the number of residents in the building. Water leaks in the system depend on the amount of water system piping damages, and damages of other elements, for example, water valves, connections, etc. The pressure in the leak area also plays an important role.

  9. Dog detectives : sniffer dogs proving indispensable in finding pipeline leaks

    Energy Technology Data Exchange (ETDEWEB)

    Lorenz, A.

    2004-09-06

    This article reports on the use of dogs to detect leaks in gas pipelines. A project was undertaken by Benoit Oilfield Construction in which dogs were trained to smell mercaptans, the odourant used by pipeline companies for safety and leak detection in natural gas. In the event of a leak, the odourant is released and migrates directly to the soil surface where it can be detected by the dogs. A leak can shut down several wells at once and can result in fines for regulatory non-compliance. If the cost of repair and cleanup is added, leaks can have a major negative financial effect on operations. The pinpointing ability of the dogs is good enough to determine if there is one large leak or several smaller ones. This helps determine if the problem resulted from a manufacturing defect or a bad welder, and thus determine who should pay the associated costs. A trained dog is worth about $11,000. 3 figs.

  10. HIGH RESOLUTION RESISTIVITY LEAK DETECTION DATA PROCESSING & EVALUATION MEHTODS & REQUIREMENTS

    Energy Technology Data Exchange (ETDEWEB)

    SCHOFIELD JS

    2007-10-04

    This document has two purposes: {sm_bullet} Describe how data generated by High Resolution REsistivity (HRR) leak detection (LD) systems deployed during single-shell tank (SST) waste retrieval operations are processed and evaluated. {sm_bullet} Provide the basic review requirements for HRR data when Hrr is deployed as a leak detection method during SST waste retrievals.

  11. 241-AY-102 Leak Detection Pit Drain Line Inspection Report

    Energy Technology Data Exchange (ETDEWEB)

    Boomer, Kayle D. [Hanford Site (HNF), Richland, WA (United States); Engeman, Jason K. [Hanford Site (HNF), Richland, WA (United States); Gunter, Jason R. [Hanford Site (HNF), Richland, WA (United States); Joslyn, Cameron C. [Hanford Site (HNF), Richland, WA (United States); Vazquez, Brandon J. [Hanford Site (HNF), Richland, WA (United States); Venetz, Theodore J. [Hanford Site (HNF), Richland, WA (United States); Garfield, John S. [AEM Consulting, Richland, WA (United States)

    2014-01-20

    This document provides a description of the design components, operational approach, and results from the Tank AY-102 leak detection pit drain piping visual inspection. To perform this inspection a custom robotic crawler with a deployment device was designed, built, and operated by IHI Southwest Technologies, Inc. for WRPS to inspect the 6-inch leak detection pit drain line.

  12. INNOVATIVE ACOUSTIC SENSOR TECHNOLOGIES FOR LEAK DETECTION IN CHALLENGING PIPE TYPES

    Science.gov (United States)

    2016-12-30

    water treatment costs. These conditions are typically associated with energy intensive water treatment processes . For example, at...overall water loss. Reduction in water loss equates to energy savings both in reduced pumping and water treatment . Leak detection technologies that... Processes to Treat the Electrodialysis Reversal (EDR) Reject Stream for the Proposed Fort Irwin Water Treatment Plant. U.S. Army Engineer

  13. Standard Test Procedures for Evaluating Various Leak Detection Methods

    Science.gov (United States)

    Learn about protocols that testers could use to demonstrate that an individual release detection equipment type could meet the performance requirements noted in the federal UST requirements for detecting leaks.

  14. Leak Detection of High Pressure Feedwater Heater Using Empirical Models

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Song Kyu; Kim, Eun Kee [Korea Power Engineering Company, Daejeon (Korea, Republic of); Heo, Gyun Young [Kyung Hee University, Yongin (Korea, Republic of); An, Sang Ha [Korea Advanced Institute of Science and Technology, Daejeon (Korea, Republic of)

    2009-10-15

    Even small leak from tube side or pass partition within the high pressure feedwater heater (HPFWH) causes a significant deficiency in its performance. Plant operation under the HPFWH leak condition for long time will result in cost increase. Tube side leak within HPFWH can produce the high velocity jet of water and it can cause neighboring tube failures. However, most of plants are being operated without any information for internal leaks of HPFWH, even though it is prone to be damaged under high temperature and high pressure operating conditions. Leaks from tubes and/or pass partition of HPFWH occurred in many nuclear power plants, for example, Mihama PS-2, Takahama PS-2 and Point Beach Nuclear Plant Unit 1. If the internal leaks of HPFWH are monitored, the cost can be reduced by inexpensive repairs relative to loss in performance and moreover plant shutdown as well as further tube damages can be prevented.

  15. Distributed Leak Detection System Using Structure-Borne Noise Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Manned spacecraft are vulnerable to air leaks caused by micrometeorite and space debris impact. The ability to detect and quickly locate and mitigate a pressure...

  16. Distributed Leak Detection System Using Structure-Borne Noise Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Manned spacecraft are vulnerable to air leaks caused by micrometeoroid and space debris impact. The ability to detect and quickly locate and mitigate a pressure...

  17. Detecting gas leaks by ultrasonic emission

    DEFF Research Database (Denmark)

    Rasmussen, Karsten Bo; Henriksen, Eigil

    1997-01-01

    The emission of noise in the frequency range 10 kHz to 25.6 kHz from an experimental gas leak in a flanged joint has been experimentally investigated. The overall conclusion is that the emitted noise is almost frequency independent in level within the considered frequency range.A small PC program...

  18. Operational tank leak detection and minimization during retrieval

    Energy Technology Data Exchange (ETDEWEB)

    Hertzel, J.S.

    1996-03-01

    This report evaluates the activities associated with the retrieval of wastes from the single-shell tanks proposed under the initial Single-Shell Tank Retrieval System. This report focuses on minimizing leakage during retrieval by using effective leak detection and mitigating actions. After reviewing the historical data available on single-shell leakage, and evaluating current leak detection technology, this report concludes that the only currently available leak detection method which can function within the most probable leakage range is the mass balance system. If utilized after each sluicing campaign, this method should allow detection at a leakage value well below the leakage value where significant health effects occur which is calculated for each tank. Furthermore, this report concludes that the planned sequence or sluicing activities will serve to further minimize the probability and volume of leaks by keeping liquid away from areas with the greatest potential for leaking. Finally, this report identifies a series of operational responses which when used in conjunction with the recommended sluicing sequence and leak detection methods will minimize worker exposure and environmental safety health risks.

  19. Color Changing Material for Hydrogen Leak Detection

    Science.gov (United States)

    Victor, Megan E.

    2014-01-01

    Kennedy Space Center scientists developed a hydrogen leak sensor utilizing a combination of chemochromic pigment and polymer that can be molded or fiber spun into rigid or flexible shapes such as tape. The sensor turns a dark color when exposed to hydrogen gas. This sensor has proven to be very effective for pinpointing the exact location of leaks in hydrogen gas lines and fittings at launch pads. Kennedy Space Center exclusively licensed this technology to the University of Central Florida (UCF), who also holds patents that are complimentary to KSC's. UCF has bundled the patents and exclusively licensed the portfolio to HySense Technology LLC, a startup company founded by a UCF professor who supports the UCF Florida Solar Energy Center (FSEC). HySense has fully developed its product (known as Intellipigment"TM"), and currently has five commercial customers. The company recently won the $100,000 first-place award at the CAT5 innovation competition at the Innovation Concourse of the Southeast: Safety & Manufacturing event in Orlando, FL. Commercial production and sales of this technology by HySense Technology will make this leak sensor widely available for use by NASA, DoD, and industries that utilize hydrogen gas.

  20. Using optical and microwave, modeled and airborne data to identify water leaks from rural aqueducts

    Science.gov (United States)

    Taylor, Frances M.; Malthus, Tim J.; Woodhouse, Iain H.; Hedger, Richard D.

    2003-03-01

    The development of techniques for the detection of water leaks from underground pipelines is seen as a high profile activity by water companies and regulators. This is due to increasing water demands and problems with current leak detection methods. In this paper optical reflectance and microwave backscatter models (SAIL + PROSPECT and RT2) were used to try and identify optimal indices for detecting water leaks amongst a variety of different land cover types at different growth stages. Results suggest that red/near infrared and red/middle infrared ratios show potential for leak detection. Given the sensitivity of L-band radar to moisture, and the ability to separate contributions from canopy and ground surface, it is possible to detect saturated soils through vegetation canopies. The results of both approaches are used to infer limits of detection in terms of season and meteorological conditions for a range of land covers. Preliminary findings suggest that leaks may be optimally detected when canopy height is low, surrounding soil is dry, and the leak has been present for more than 14 days. The modelled data is compared with L - band fully polarimetric E-SAR data, and 200 channel HYMAP hyperspectral airborne data which were acquired over an 8km section of the Vrynwy aqueduct (UK), which included a high concentration of leaks. Data was acquired as part of the British National Space Centre (BNSC) and Natural Environmental Research Council (NERC), SAR and Hyperspectral Airborne Campaign (SHAC) in June 2000. The results from this work suggest that remote sensing is both an effective and feasible tool for leak identification.

  1. Technical Reviews on the Radioisotope Application for Leak Detection in Reservoirs

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jin Seop; Jung, Sung Hee; Kim, Jong Bum; Kim, Jae Ho

    2006-02-15

    The previous techniques on the detection of leaks from reservoirs are difficult to identify the leak points and leak pathways in reservoirs. Additionally the complexity and ambiguity of data analysis resulted from them can increase the failures of leak detection. While, The technique using radioisotope as a tracer is considered to be very promising. In the same context, systematic studies led by IAEA are being practiced by organizing the task force team. The detection technique using natural tracer can give information about the age of ground water and the interconnection between ground water and reservoir water and the seepage origin. On the other hand, the one using artificial tracer can identify the leak point in reservoirs directly, in which radioactive cloud migration method and radioactive tracer adsorption method are included. The former is using hydrophilic radioisotope tracer, and the latter adsorptive radioisotope tracer which is emitting gamma ray. The radiotracer are injected at a point of the reservoir near to the bottom. Afterwards, the migration of the radioactive tracer is followed by means of submerged scintillation detectors suspended from boats. Usually {sup 131}I, {sup 82}Br, {sup 46}Sc, and {sup 198}Au etc. can be used as tracer. The point reaching the maximum concentration of tracer corresponds to the leak point in reservoirs.

  2. Technical basis for inner container leak detection sensitivity goals in 3013 DE surveillance

    Energy Technology Data Exchange (ETDEWEB)

    Berg, John M. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-08-11

    Helium leak checking of 3013 inner container lids is under consideration for addition to DE Surveillance tasks as an improved means to detect any through-wall flaws that may have formed during storage. This white paper evaluates whether leak checking at DE could replace and improve upon the current method of comparing gas compositions and pressures within the inner and outer containers. We have used viscous and molecular flow equations in ANSI N14.5 to calculate what the measured standard helium leak rate would be for hypothetical leaks of three different sizes. For comparison, we have also calculated the effects on gas composition and pressure differences as a function of pre-DE storage time for the same three leak sizes, using molecular and viscous flow equations as well as diffusion equations to predict the relevant gas transport. For a hypothetical leak that would be measured at 1x10-7 std cc/sec, likely an achievable sensitivity using helium leak checking at DE, the calculations predict no measurable effect on pressure difference or gas composition as measured by DE gas analysis. We also calculate that it would take over 200 years for water vapor to diffuse through a 10-7 std cc/sec leak enough to raise the RH outer container to half the RH value in the inner container. A leak 100 times larger, which would be measured at 1x10-5 std cc/sec, the same water vapor diffusion would take at least 14 years. Our conclusion is that helium leak checking will be useful even at a sensitivity of 1x10-5 std cc/sec, and a significant improvement over current DE methods at a sensitivity of 1x10-7 std cc/sec.

  3. Autogenous Metallic Pipe Leak Repair in Potable Water Systems.

    Science.gov (United States)

    Tang, Min; Triantafyllidou, Simoni; Edwards, Marc A

    2015-07-21

    Copper and iron pipes have a remarkable capability for autogenous repair (self-repair) of leaks in potable water systems. Field studies revealed exemplars that metallic pipe leaks caused by nails, rocks, and erosion corrosion autogenously repaired, as confirmed in the laboratory experiments. This work demonstrated that 100% (N = 26) of 150 μm leaks contacting representative bulk potable water in copper pipes sealed autogenously via formation of corrosion precipitates at 20-40 psi, pH 3.0-11.0, and with upward and downward leak orientations. Similar leaks in carbon steel pipes at 20 psi self-repaired at pH 5.5 and 8.5, but two leaks did not self-repair permanently at pH 11.0 suggesting that water chemistry may control the durability of materials that seal the leaks and therefore the permanence of repair. Larger 400 μm holes in copper pipes had much lower (0-33%) success of self-repair at pH 3.0-11.0, whereas all 400 μm holes in carbon steel pipes at 20 psi self-repaired at pH 4.0-11.0. Pressure tests indicated that some of the repairs created at 20-40 psi ambient pressure could withstand more than 100 psi without failure. Autogenous repair has implications for understanding patterns of pipe failures, extending the lifetime of decaying infrastructure, and developing new plumbing materials.

  4. A statistical analysis on the leak detection performance of ...

    Indian Academy of Sciences (India)

    This paper attempts to provide a statistical insight on the concepts of leak detection performance of WSNs when deployed on overground and underground pipelines.The approach in the study employs the hypothesis testing problem to formulate a solution on the detection plan.Through the hypothesis test, the maximum ...

  5. Safe Detection System for Hydrogen Leaks

    Energy Technology Data Exchange (ETDEWEB)

    Lieberman, Robert A. [Intelligent Optical Systems, Inc., Torrance, CA (United States); Beshay, Manal [Intelligent Optical Systems, Inc., Torrance, CA (United States)

    2012-02-29

    Hydrogen is an "environmentally friendly" fuel for future transportation and other applications, since it produces only pure ("distilled") water when it is consumed. Thus, hydrogen-powered vehicles are beginning to proliferate, with the total number of such vehicles expected to rise to nearly 100,000 within the next few years. However, hydrogen is also an odorless, colorless, highly flammable gas. Because of this, there is an important need for hydrogen safety monitors that can warn of hazardous conditions in vehicles, storage facilities, and hydrogen production plants. To address this need, IOS has developed a unique intrinsically safe optical hydrogen sensing technology, and has embodied it in detector systems specifically developed for safety applications. The challenge of using light to detect a colorless substance was met by creating chemically-sensitized optical materials whose color changes in the presence of hydrogen. This reversible reaction provides a sensitive, reliable, way of detecting hydrogen and measuring its concentration using light from low-cost LEDs. Hydrogen sensors based on this material were developed in three completely different optical formats: point sensors ("optrodes"), integrated optic sensors ("optical chips"), and optical fibers ("distributed sensors") whose entire length responds to hydrogen. After comparing performance, cost, time-to-market, and relative market need for these sensor types, the project focused on designing a compact optrode-based single-point hydrogen safety monitor. The project ended with the fabrication of fifteen prototype units, and the selection of two specific markets: fuel cell enclosure monitoring, and refueling/storage safety. Final testing and development of control software for these markets await future support.

  6. High Altitude Aerial Natural Gas Leak Detection System

    Energy Technology Data Exchange (ETDEWEB)

    Richard T. Wainner; Mickey B. Frish; B. David Green; Matthew C. Laderer; Mark G. Allen; Joseph R. Morency

    2006-12-31

    The objective of this program was to develop and demonstrate a cost-effective and power-efficient advanced standoff sensing technology able to detect and quantify, from a high-altitude (> 10,000 ft) aircraft, natural gas leaking from a high-pressure pipeline. The advanced technology is based on an enhanced version of the Remote Methane Leak Detector (RMLD) platform developed previously by Physical Sciences Inc. (PSI). The RMLD combines a telecommunications-style diode laser, fiber-optic components, and low-cost DSP electronics with the well-understood principles of Wavelength Modulation Spectroscopy (WMS), to indicate the presence of natural gas located between the operator and a topographic target. The transceiver transmits a laser beam onto a topographic target and receives some of the laser light reflected by the target. The controller processes the received light signal to deduce the amount of methane in the laser's path. For use in the airborne platform, we modified three aspects of the RMLD, by: (1) inserting an Erbium-doped optical fiber laser amplifier to increase the transmitted laser power from 10 mW to 5W; (2) increasing the optical receiver diameter from 10 cm to 25 cm; and (3) altering the laser wavelength from 1653 nm to 1618 nm. The modified RMLD system provides a path-integrated methane concentration sensitivity {approx}5000 ppm-m, sufficient to detect the presence of a leak from a high capacity transmission line while discriminating against attenuation by ambient methane. In ground-based simulations of the aerial leak detection scenario, we demonstrated the ability to measure methane leaks within the laser beam path when it illuminates a topographic target 2000 m away. We also demonstrated simulated leak detection from ranges of 200 m using the 25 cm optical receiver without the fiber amplifier.

  7. FUZZY INFERENCE BASED LEAK ESTIMATION IN WATER PIPELINES SYSTEM

    Directory of Open Access Journals (Sweden)

    N. Lavanya

    2015-01-01

    Full Text Available Pipeline networks are the most widely used mode for transporting fluids and gases around the world. Leakage in this pipeline causes harmful effects when the flowing fluid/gas is hazardous. Hence the detection of leak becomes essential to avoid/minimize such undesirable effects. This paper presents the leak detection by spectral analysis methods in a laboratory pipeline system. Transient in the pressure signal in the pipeline is created by opening and closing the exit valve. These pressure variations are captured and power spectrum is obtained by using Fast Fourier Transform (FFT method and Filter Diagonalization Method (FDM. The leaks at various positions are simulated and located using these methods and the results are compared. In order to determine the quantity of leak a 2 × 1 fuzzy inference system is created using the upstream and downstream pressure as input and the leak size as the output. Thus a complete leak detection, localization and quantification are done by using only the pressure variations in the pipeline.

  8. Hermetic Seal Leak Detection Apparatus with Variable Size Test Chamber

    Science.gov (United States)

    Kelley, Anthony R. (Inventor)

    2015-01-01

    The present invention is a versatile hermetic seal leak detection apparatus for testing hermetically sealed containers and devices for leaks without the need to create a custom or specially manufactured testing chamber conforming to the dimensions of the specific object under test. The size of the testing chamber may be mechanically adjusted by the novel use of bellows to reduce and optimize the amount of gas space in a test chamber which surrounds the hermetically sealed object under test. The present invention allows the size of the test chamber to be selectively adjusted during testing to provide an optimum test chamber gas space. The present invention may be further adapted to isolate and test specific portions of the hermetically sealed object under test for leaks.

  9. Least squares deconvolution for leak detection with a pseudo random binary sequence excitation

    Science.gov (United States)

    Nguyen, Si Tran Nguyen; Gong, Jinzhe; Lambert, Martin F.; Zecchin, Aaron C.; Simpson, Angus R.

    2018-01-01

    Leak detection and localisation is critical for water distribution system pipelines. This paper examines the use of the time-domain impulse response function (IRF) for leak detection and localisation in a pressurised water pipeline with a pseudo random binary sequence (PRBS) signal excitation. Compared to the conventional step wave generated using a single fast operation of a valve closure, a PRBS signal offers advantageous correlation properties, in that the signal has very low autocorrelation for lags different from zero and low cross correlation with other signals including noise and other interference. These properties result in a significant improvement in the IRF signal to noise ratio (SNR), leading to more accurate leak localisation. In this paper, the estimation of the system IRF is formulated as an optimisation problem in which the l2 norm of the IRF is minimised to suppress the impact of noise and interference sources. Both numerical and experimental data are used to verify the proposed technique. The resultant estimated IRF provides not only accurate leak location estimation, but also good sensitivity to small leak sizes due to the improved SNR.

  10. Leak detection, monitoring, and mitigation technology trade study update

    Energy Technology Data Exchange (ETDEWEB)

    HERTZEL, J.S.

    1998-11-10

    This document is a revision and update to the initial report that describes various leak detection, monitoring, and mitigation (LDMM) technologies that can be used to support the retrieval of waste from the single-shell tanks (SST) at the Hanford Site. This revision focuses on the improvements in the technical performance of previously identified and useful technologies, and it introduces new technologies that might prove to be useful.

  11. Leak detection and localization system through acoustics; Sistema de deteccao e localizacao de vazamentos por acustica

    Energy Technology Data Exchange (ETDEWEB)

    Alonso, Julio [Aselco Automacao, Sao Paulo, SP (Brazil)

    2003-07-01

    Acoustic Leak Detection Systems (ALDS) are used on both liquid and gas pipelines as well as multi-phase flow pipelines to detect leaks quickly and provide a means of limiting product loss. The real-time acoustic signal is continuously compared against signature leak profiles for the particular operating and geometric conditions. These profiles were developed from a database established from over 20 years of experimental and field leak tests. This technique not only drastically reduces the false alarm rate, but also significantly improves the sensitivity and leak location accuracy. This system will also detect leaks with shut-in flow (zero flow rate in the pipeline). With the use of GPS (Global Positioning System) it not only improves leak location accuracy, but also allows for continuous leak detection during the loss of communications. (author)

  12. Passive Leak Detection Using Commercial Hydrogen Colorimetric Indicator

    Energy Technology Data Exchange (ETDEWEB)

    Hartmann, Kevin [National Renewable Energy Lab. (NREL), Golden, CO (United States); Buttner, William [National Renewable Energy Lab. (NREL), Golden, CO (United States); Burgess, Robert [National Renewable Energy Lab. (NREL), Golden, CO (United States); Rivkin, Carl [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2016-09-01

    Element One, Inc. (www.elem.com), a small business with in Boulder, CO, has been developing hydrogen detection technology based upon a highly selective colorimetric indicator. In its native state, the indicator pigment is a pale gray color, but becomes black upon exposure to hydrogen. The colorimetric change can be readily observed by the naked eye without the need for supplemental electronics or other hardware. Recently, the colorimetric indicator was integrated into a pliable, self-adhesive tape that can readily wrap around pneumatic fittings to serve as a hydrogen leak detector. A prototype version of the Element One indicator tape was tested within an NREL hydrogen system and successfully identified the unexpected presence of a small leak; a summary document for this case study is presented in Appendix 1. The tape was subsequently configured into 10-foot rolls as a product prototype that has just recently been commercialized and marketed under the tradename DetecTape(R). Figure 1 shows the commercial version of DetecTape along with an indicator sample in its native state and one that had been exposed to hydrogen. DetecTape is a self-adhesive silicone-based tape impregnated with a proprietary hydrogen-sensitive indicator based on transition metal oxides. A length of the tape can be cut from the roll and stretched by a factor of two or three times around a fitting. Due to the self-adhesive property of the tape, this provides a tight seal around the fitting. The seal is not hermetic, and is not intended to prevent the release of a leaking gas. However, a portion of the hydrogen leaking from a wrapped fitting will pass through the tape and react with the active indicator impregnated within the tape, thereby inducing blackening.

  13. PORTABLE IMAGING DEVICES FOR INDUSTRIAL LEAK DETECTION AT PETROLEUM REFINERIES AND CHEMICAL PLANTS

    Science.gov (United States)

    Undiscovered gas leaks, or fugitive emissions, in chemical plants and refinery operations can impact regional air quality as well as being a public health problem. Surveying a facility for potential gas leaks can be a daunting task. Industrial Leak Detection and Repair (LDAR) pro...

  14. A Hybrid Heuristic Optimization Approach for Leak Detection in Pipe Networks Using Ordinal Optimization Approach and the Symbiotic Organism Search

    Directory of Open Access Journals (Sweden)

    Chao-Chih Lin

    2017-10-01

    Full Text Available A new transient-based hybrid heuristic approach is developed to optimize a transient generation process and to detect leaks in pipe networks. The approach couples the ordinal optimization approach (OOA and the symbiotic organism search (SOS to solve the optimization problem by means of iterations. A pipe network analysis model (PNSOS is first used to determine steady-state head distribution and pipe flow rates. The best transient generation point and its relevant valve operation parameters are optimized by maximizing the objective function of transient energy. The transient event is created at the chosen point, and the method of characteristics (MOC is used to analyze the transient flow. The OOA is applied to sift through the candidate pipes and the initial organisms with leak information. The SOS is employed to determine the leaks by minimizing the sum of differences between simulated and computed head at the observation points. Two synthetic leaking scenarios, a simple pipe network and a water distribution network (WDN, are chosen to test the performance of leak detection ordinal symbiotic organism search (LDOSOS. Leak information can be accurately identified by the proposed approach for both of the scenarios. The presented technique makes a remarkable contribution to the success of leak detection in the pipe networks.

  15. Corrosion Evaluation of Tank 40 Leak Detection Box

    Energy Technology Data Exchange (ETDEWEB)

    Mickalonis, J.I.

    1999-07-29

    'Leak detection from the transfer lines in the tank farm has been a concern for many years because of the need to minimize exposure of personnel and contamination of the environment. The leak detection box (LDB) is one line of defense, which must be maintained to meet this objective. The evaluation of a failed LDB was one item from an action plan aimed at minimizing the degradation of LDBs. The Tank 40 LDB, which failed in service, was dug up and shipped to SRTC for evaluation. During a video inspection while in service, this LDB was found to have black tubercles on the interior, which suggested possible microbial involvement. The failure point, however, was believed to have occurred in the drain line from the transfer line jacket. Visual, metallurgical, and biological analyses were performed on the LDB. The analysis results showed that there was not any adverse microbiological growth or significant localized corrosion. The corrosion of the LDB was caused by exposure to aqueous environments and was typical of carbon steel pipes in soil environments.'

  16. Quantitative risk assessment & leak detection criteria for a subsea oil export pipeline

    Science.gov (United States)

    Zhang, Fang-Yuan; Bai, Yong; Badaruddin, Mohd Fauzi; Tuty, Suhartodjo

    2009-06-01

    A quantitative risk assessment (QRA) based on leak detection criteria (LDC) for the design of a proposed subsea oil export pipeline is presented in this paper. The objective of this QRA/LDC study was to determine if current leak detection methodologies were sufficient, based on QRA results, while excluding the use of statistical leak detection; if not, an appropriate LDC for the leak detection system would need to be established. The famous UK PARLOC database was used for the calculation of pipeline failure rates, and the software POSVCM from MMS was used for oil spill simulations. QRA results revealed that the installation of a statistically based leak detection system (LDS) can significantly reduce time to leak detection, thereby mitigating the consequences of leakage. A sound LDC has been defined based on QRA study results and comments from various LDS vendors to assist the emergency response team (ERT) to quickly identify and locate leakage and employ the most effective measures to contain damage.

  17. The Leaking-Toilet Challenge

    Science.gov (United States)

    Roman, Harry T.

    2008-01-01

    Leaking toilets can cost homeowners big dollars--often before it is even realized. Homeowners do not necessarily hear it leaking. It just does, and when the water bill comes due, it can be a most unpleasant surprise. This article presents a classroom challenge to try to develop leak-detection ideas that would be inexpensive and easily added to…

  18. A Hydrogen Leak Detection System for Aerospace and Commercial Applications

    Science.gov (United States)

    Hunter, Gary W.; Makel, D. B.; Jansa, E. D.; Patterson, G.; Cova, P. J.; Liu, C. C.; Wu, Q. H.; Powers, W. T.

    1995-01-01

    Leaks on the space shuttle while on the launch pad have generated interest in hydrogen leak monitoring technology. Microfabricated hydrogen sensors are being fabricated at Case Western Reserve University (CWRU) and tested at NASA Lewis Research Center (LeRC). These sensors have been integrated into hardware and software designed by Aerojet. This complete system allows for multipoint leak monitoring designed to provide leak source and magnitude information in real time. The monitoring system processes data from the hydrogen sensors and presents the operator with a visual indication of the leak location and magnitude. Although the leak monitoring system was designed for hydrogen propulsion systems, the possible applications of this monitoring system are wide ranged. This system is in operation in an automotive application which requires high sensitivity to hydrogen.

  19. Minimum detectable gas concentration performance evaluation method for gas leak infrared imaging detection systems.

    Science.gov (United States)

    Zhang, Xu; Jin, Weiqi; Li, Jiakun; Wang, Xia; Li, Shuo

    2017-04-01

    Thermal imaging technology is an effective means of detecting hazardous gas leaks. Much attention has been paid to evaluation of the performance of gas leak infrared imaging detection systems due to several potential applications. The minimum resolvable temperature difference (MRTD) and the minimum detectable temperature difference (MDTD) are commonly used as the main indicators of thermal imaging system performance. This paper establishes a minimum detectable gas concentration (MDGC) performance evaluation model based on the definition and derivation of MDTD. We proposed the direct calculation and equivalent calculation method of MDGC based on the MDTD measurement system. We build an experimental MDGC measurement system, which indicates the MDGC model can describe the detection performance of a thermal imaging system to typical gases. The direct calculation, equivalent calculation, and direct measurement results are consistent. The MDGC and the minimum resolvable gas concentration (MRGC) model can effectively describe the performance of "detection" and "spatial detail resolution" of thermal imaging systems to gas leak, respectively, and constitute the main performance indicators of gas leak detection systems.

  20. Improving airway segmentation in computed tomography using leak detection with convolutional networks

    NARCIS (Netherlands)

    Charbonnier, J.P.; Rikxoort, E.M. van; Setio, A.A.A.; Schaefer-Prokop, C.M.; Ginneken, B. van; Ciompi, F.

    2017-01-01

    We propose a novel method to improve airway segmentation in thoracic computed tomography (CT) by detecting and removing leaks. Leak detection is formulated as a classification problem, in which a convolutional network (ConvNet) is trained in a supervised fashion to perform the classification task.

  1. DETECCIÓN DE PÉRDIDAS EN TUBERÍAS DE AGUA: PROPUESTA BASADA EN UN BANCO DE FILTROS LEAK DETECTION IN WATER PIPELINES: PROPOSAL BASED ON A BANK OF FILTERS

    Directory of Open Access Journals (Sweden)

    Lucía Castro Burgos

    2009-12-01

    Full Text Available Actualmente la detección de pérdidas (DP en tuberías de agua es un área de investigación activa, y con un creciente interés, debido a la importancia del transporte seguro del vital elemento. Este trabajo considera el problema de DP en tuberías de agua por medio de redundancia analítica, basada en un modelo matemático y utilizando técnicas de estimación de estados, teniendo por objetivo principal estudiar, proponer, implementar y aplicar algoritmos eficientes que permitan abordar de manera general el problema de DP. Para lograr esto se propone y evalúa un banco de filtros, implementados con filtros de Kalman (FK y filtros de partículas (FP. Con esto se busca contribuir conceptualmente a la formulación del problema de DP, de manera modular, permitiendo que en un estudio futuro otras técnicas puedan ser utilizadas para resolver el problema. Además, obtener algoritmos eficientes y confiables, basados en un estimador de estados capaces de responder a requerimientos industriales, tales como: entregar, a partir de medidas de entrada y salida disponibles, una estimación fiable del estado del proceso, esto con independencia de la dinámica lineal o no lineal, asimismo, ser de fácil manejo y fácil configuración. La simulación computacional y los resultados experimentales muestran la efectividad de combinar FP con FK, para el caso básico de dos pérdidas secuenciales en una tubería, presentando ventajas de rápida convergencia y reducción del error de estimación, factores importantes en el problema de DP en ductos hídricos.Currently leak detection (LD in water pipelines is an active area of research that is attracting increasing interest due to the importance of the safe transport of this vital resource. This work considers the problem of LD in water pipes by means of analytical redundancy, based on a mathematical model and using state estimation techniques. The main aim of this work is to research, propose, implement and apply

  2. Optimal pressure sensor placement in water distribution networks minimizing leak location uncertainty

    OpenAIRE

    Nejjari, Fatiha; Sarrate, Ramon; Blesa, Joaquim

    2015-01-01

    In this paper an optimal sensor placement strategy based on pressure sensitivity matrix analysis and an exhaustive search strategy that maximizes some diagnosis specifications for a water distribution network is presented. An average worst leak expansion distance as a new leak location performance measure has been proposed. This metric is later used to assess the leak location uncertainty provided by a sensor configuration. The method is combined with a clustering technique in order to reduce...

  3. Using Decision Trees to Detect and Isolate Simulated Leaks in the J-2X Rocket Engine

    Science.gov (United States)

    Schwabacher, Mark A.; Aguilar, Robert; Figueroa, Fernando F.

    2009-01-01

    The goal of this work was to use data-driven methods to automatically detect and isolate faults in the J-2X rocket engine. It was decided to use decision trees, since they tend to be easier to interpret than other data-driven methods. The decision tree algorithm automatically "learns" a decision tree by performing a search through the space of possible decision trees to find one that fits the training data. The particular decision tree algorithm used is known as C4.5. Simulated J-2X data from a high-fidelity simulator developed at Pratt & Whitney Rocketdyne and known as the Detailed Real-Time Model (DRTM) was used to "train" and test the decision tree. Fifty-six DRTM simulations were performed for this purpose, with different leak sizes, different leak locations, and different times of leak onset. To make the simulations as realistic as possible, they included simulated sensor noise, and included a gradual degradation in both fuel and oxidizer turbine efficiency. A decision tree was trained using 11 of these simulations, and tested using the remaining 45 simulations. In the training phase, the C4.5 algorithm was provided with labeled examples of data from nominal operation and data including leaks in each leak location. From the data, it "learned" a decision tree that can classify unseen data as having no leak or having a leak in one of the five leak locations. In the test phase, the decision tree produced very low false alarm rates and low missed detection rates on the unseen data. It had very good fault isolation rates for three of the five simulated leak locations, but it tended to confuse the remaining two locations, perhaps because a large leak at one of these two locations can look very similar to a small leak at the other location.

  4. Leak detection systems for uranium mill tailings impoundments with synthetic liners

    Energy Technology Data Exchange (ETDEWEB)

    Myers, D.A.; Tyler, S.W.; Gutknecht, P.J.; Mitchell, D.H.

    1983-09-01

    This study evaluated the performance of existing and alternative leak detection systems for lined uranium mill tailings ponds. Existing systems for detecting leaks at uranium mill tailings ponds investigated in this study included groundwater monitoring wells, subliner drains, and lysimeters. Three alternative systems which demonstrated the ability to locate leaks in bench-scale tests included moisture blocks, soil moisture probes, and a soil resistivity system. Several other systems in a developmental stage are described. For proper performance of leak detection systems (other than groundwater wells and lysimeters), a subgrade is required which assures lateral dispersion of a leak. Methods to enhance dispersion are discussed. Cost estimates were prepared for groundwater monitoring wells, subliner drain systems, and the three experimental systems. Based on the results of this report, it is suggested that groundwater monitoring systems be used as the primary means of leak detection. However, if a more responsive system is required due to site characteristics and groundwater quality criteria, subliner drains are applicable for ponds with uncovered liners. Leak-locating systems for ponds with covered liners require further development. Other recommendations are discussed in the report.

  5. Using Decision Trees to Detect and Isolate Leaks in the J-2X

    Data.gov (United States)

    National Aeronautics and Space Administration — Full title: Using Decision Trees to Detect and Isolate Simulated Leaks in the J-2X Rocket Engine Mark Schwabacher, NASA Ames Research Center Robert Aguilar, Pratt...

  6. An Evaluation of liquid metal leak detection methods for the Clinch River Breeder Reactor Plant

    Energy Technology Data Exchange (ETDEWEB)

    Morris, C.J.; Doctor, S.R.

    1977-12-01

    This report documents an independent review and evaluation of sodium leak detection methods described in the Clinch River Breeder Reactor Preliminary Safety Analysis Report. Only information in publicly available documents was used in making the assessments.

  7. Portable Rapid Test Fuel Tank Leak Detection System

    Science.gov (United States)

    2010-04-01

    the site-specific test parameters and selects the “Start Test” icon . Leak test final results can be obtained in less than 5 hours. 3.0 PROTOTYPE...the reference tube into section lengths of less than 7 feet for shipping, and 3) downsizing the reference tube diameter to reduce weight and for

  8. Detecting well casing leaks in Bangladesh using a salt spiking method

    Science.gov (United States)

    Stahl, M.O.; Ong, J.B.; Harvey, C.F.; Johnson, C.D.; Badruzzaman, A.B.M.; Tarek, M.H.; VanGeen, A.; Anderson, J.A.; Lane, J.W.

    2014-01-01

    We apply fluid-replacement logging in arsenic-contaminated regions of Bangladesh using a low-cost, down-well fluid conductivity logging tool to detect leaks in the cased section of wells. The fluid-conductivity tool is designed for the developing world: it is lightweight and easily transportable, operable by one person, and can be built for minimal cost. The fluid-replacement test identifies leaking casing by comparison of fluid conductivity logs collected before and after spiking the wellbore with a sodium chloride tracer. Here, we present results of fluid-replacement logging tests from both leaking and non-leaking casing from wells in Araihazar and Munshiganj, Bangladesh, and demonstrate that the low-cost tool produces measurements comparable to those obtained with a standard geophysical logging tool. Finally, we suggest well testing procedures and approaches for preventing casing leaks in Bangladesh and other developing countries.

  9. INNOVATIVE ACOUSTIC SENSOR TECHNOLOGIES FOR LEAK DETECTION IN CHALLENGING PIPE TYPES

    Science.gov (United States)

    2016-12-30

    computer modeling platform to track all military assets, including potable water systems to manage life cycle repair, degradation assessment, and...evidence of significant water flow on the surface. The field test excavation revealed that the leak was under the slab of a building. Further research...and development is needed to address location of leaks that may be underneath building slabs or other surface features. In an actual field application

  10. GPR-Based Water Leak Models in Water Distribution Systems

    Directory of Open Access Journals (Sweden)

    David Ayala–Cabrera

    2013-11-01

    Full Text Available This paper addresses the problem of leakage in water distribution systems through the use of ground penetrating radar (GPR as a nondestructive method. Laboratory tests are performed to extract features of water leakage from the obtained GPR images. Moreover, a test in a real-world urban system under real conditions is performed. Feature extraction is performed by interpreting GPR images with the support of a pre-processing methodology based on an appropriate combination of statistical methods and multi-agent systems. The results of these tests are presented, interpreted, analyzed and discussed in this paper.

  11. Helium Mass Spectrometer Leak Detection: A Method to Quantify Total Measurement Uncertainty

    Science.gov (United States)

    Mather, Janice L.; Taylor, Shawn C.

    2015-01-01

    In applications where leak rates of components or systems are evaluated against a leak rate requirement, the uncertainty of the measured leak rate must be included in the reported result. However, in the helium mass spectrometer leak detection method, the sensitivity, or resolution, of the instrument is often the only component of the total measurement uncertainty noted when reporting results. To address this shortfall, a measurement uncertainty analysis method was developed that includes the leak detector unit's resolution, repeatability, hysteresis, and drift, along with the uncertainty associated with the calibration standard. In a step-wise process, the method identifies the bias and precision components of the calibration standard, the measurement correction factor (K-factor), and the leak detector unit. Together these individual contributions to error are combined and the total measurement uncertainty is determined using the root-sum-square method. It was found that the precision component contributes more to the total uncertainty than the bias component, but the bias component is not insignificant. For helium mass spectrometer leak rate tests where unit sensitivity alone is not enough, a thorough evaluation of the measurement uncertainty such as the one presented herein should be performed and reported along with the leak rate value.

  12. Good versus Good Enough? Empirical tests of methane leak detection sensitivity of a commercial infrared camera.

    Science.gov (United States)

    Ravikumar, Arvind P; Wang, Jingfan; McGuire, Mike; Bell, Clay S; Zimmerle, Daniel; Brandt, Adam R

    2018-01-19

    Methane - a key component of natural gas - is a potent greenhouse gas. A key feature of recent methane mitigation policies is the use of periodic leak detection surveys, typically done with optical gas imaging (OGI) technologies. The most common OGI technology is an infrared camera. In this work, we experimentally develop detection probability curves for OGI-based methane leak detection under different environmental and imaging conditions. Controlled single blind leak detection tests show that the median detection limit (50% detection likelihood) for FLIR-camera based OGI technology is about 20 g CH4/h at an imaging distance of 6 m, an order of magnitude higher than previously reported estimates of 1.4 g CH4/h. Furthermore, we show that median and 90% detection likelihood limit follows a power-law relationship with imaging distance. Finally, we demonstrate that real-world marginal effectiveness of methane mitigation through periodic surveys approaches zero as leak detection sensitivity improves. For example, a median detection limit of 100 g CH4/h is sufficient to detect the maximum amount of leakage that is possible through periodic surveys. Policy makers should take note of these limits while designing equivalence metrics for next-generation leak detection technologies that can trade sensitivity for cost without affecting mitigation priorities.

  13. AIRBORNE, OPTICAL REMOTE SENSNG OF METHANE AND ETHANE FOR NATURAL GAS PIPELINE LEAK DETECTION

    Energy Technology Data Exchange (ETDEWEB)

    Jerry Myers

    2005-04-15

    Ophir Corporation was awarded a contract by the U. S. Department of Energy, National Energy Technology Laboratory under the Project Title ''Airborne, Optical Remote Sensing of Methane and Ethane for Natural Gas Pipeline Leak Detection'' on October 14, 2002. The scope of the work involved designing and developing an airborne, optical remote sensor capable of sensing methane and, if possible, ethane for the detection of natural gas pipeline leaks. Flight testing using a custom dual wavelength, high power fiber amplifier was initiated in February 2005. Ophir successfully demonstrated the airborne system, showing that it was capable of discerning small amounts of methane from a simulated pipeline leak. Leak rates as low as 150 standard cubic feet per hour (scf/h) were detected by the airborne sensor.

  14. Implementation of leak detection techniques in ducts with critical regimen multiphase flow; Implementacao de tecnicas de deteccao de vazamentos em dutos em regime de escoamento multifasico critico

    Energy Technology Data Exchange (ETDEWEB)

    Martins, Rodrigo S.; Maitelli, Andr L.; Doria Neto, Adriao D.; Salazar, Andres O. [Rio Grande do Norte Univ., Natal, RN (Brazil)

    2005-07-01

    This paper presents signals processing techniques and artificial neural networks to identify leaks in multiphase flow pipeline. The greatest difficulty on traditional methods of leak detection (volume balance, pressure point analysis, etc) is that they are insufficient to design an adequate profile for the real conditions of oil pipeline transport. These difficult conditions goes since unevenly soil, that cause columns or vacuum throughout pipelines, until the presence of multi phases like water, gas and oil; plus other components as sand, which use to produce discontinuous flow off and diverse variations. To attenuate these difficulties, the transform wavelet was used to map the signal pressure in different resolution plan allowing the extraction of descriptors that identify leaks patterns and with then to provide training for the neural network multilayer perceptron (MLP) to learning of how to classify this pattern and report whenever this characterize leaks. During the tests were used transient and regime signals and pipelines with punctures with size variations from 1/2'' to 1'' of diameter to simulate leaks and, this way, it was possible to detect leaks with a time window of two minutes. The result show that the proposed descriptors considered, based in statistical methods applied in domain transform, are sufficient to identify leaks patterns and make it possible to train the neural classifier to indicate the occurrence of pipeline leaks. (author)

  15. Solving Leak Testing Challenges

    National Research Council Canada - National Science Library

    John Sprovieri

    2007-01-01

    .... InterTech provided two Model 1075 pressure-decay leak detectors to perform the three tests-a leak test at 220 inches of water column, a leak test at 5 inches of water column, and a forward direction...

  16. New Sensor Cable for the Detection and Location of Leaks in Pipelines for Transportation of Hydrocarbons

    Directory of Open Access Journals (Sweden)

    E.Orduña-Reyes

    2012-08-01

    Full Text Available At present, hydrocarbon leaks, generated mainly by corrosion of pipelines, cause large economic losses for Mexico.These leaks constitute a problem of serious consequences in Mexico and in other countries in the world. This workdescribes the results of the tests conducted on a new sensor cable for the detection and location of leaks in pipelinesfor transportation of hydrocarbons. When a liquid or gas enters in contact with the wall of the sensor cable, it causes ashort circuit in the wires; changing the measurement of the resistance may detect and locate the leak. The new sensorcable that is presented in this article has advantages over cables with similar characteristic made in other countries.The use of this sensor cable in pipelines of PEMEX will avoid economic losses, environmental damage and risks ofpossible explosions to the population. The experimental results demonstrate these advantages.

  17. Leaks in gas pipelines. Leak detection with the aid of GIS and GPS; Leckstellen in Gasrohrnetzen. Aufspueren mit Unterstuetzung durch GIS und GPS

    Energy Technology Data Exchange (ETDEWEB)

    Huber, Detlef; Berteld, Michael [Industrielle Werke Basel (Switzerland)

    2009-12-15

    The GPS technology has made gas leak detection more efficient. By linking it with the documentation of the Geographic Information System (GIS), gas grid monitoring, long-term planning and also maintenance can be optimized considerably. After successful testing, Industrielle Werke Basel (IWB) introduced the system for their whole gas grid. Apart from cost savings, there was also a significant quality improvement in gas leak detection. (orig.)

  18. Management of water leaks on Tore Supra actively cooled fusion device

    Energy Technology Data Exchange (ETDEWEB)

    Hatchressian, J.C.; Gargiulo, L.; Samaille, F.; Soler, B

    2005-07-01

    Up to now, Tore Supra is the only fusion device fully equipped with actively cooled Plasma Facing Components (PFCs). In case of abnormal events during a plasma discharge, the PFCs could be submitted to a transient high power density (run away electrons) or to a continuous phenomena as local thermal flux induced by trapped suprathermal electrons or ions). It could lead to a degradation of the PFC integrity and in the worst case to a water leak occurrence. Such water leak has important consequence on the tokamak operation that concerns PFCs themselves, monitoring equipment located in the vacuum vessel or connected to the ports as RF antennas, diagnostics or pumping systems. Following successive water leak events (the most important water leak, that occurred in September 2002, is described in the paper), a large feedback experience has been gained on Tore supra since more than 15 years that could be useful to actively cooled next devices as W7X and ITER. (authors)

  19. Detecting subsurface fluid leaks in real-time using injection and production rates

    Science.gov (United States)

    Singh, Harpreet; Huerta, Nicolas J.

    2017-12-01

    CO2 injection into geologic formations for either enhanced oil recovery or carbon storage introduces a risk for undesired fluid leakage into overlying groundwater or to the surface. Despite decades of subsurface CO2 production and injection, the technologies and methods for detecting CO2 leaks are still costly and prone to large uncertainties. This is especially true for pressure-based monitoring methods, which require the use of simplified geological and reservoir flow models to simulate the pressure behavior as well as background noise affecting pressure measurements. In this study, we propose a method to detect the time and volume of fluid leakage based on real-time measurements of well injection and production rates. The approach utilizes analogies between fluid flow and capacitance-resistance modeling. Unlike other leak detection methods (e.g. pressure-based), the proposed method does not require geological and reservoir flow models to simulate the behavior that often carry significant sources of uncertainty; therefore, with our approach the leak can be detected with greater certainty. The method can be applied to detect when a leak begins by tracking a departure in fluid production rate from the expected pattern. The method has been tuned to detect the effect of boundary conditions and fluid compressibility on leakage. To highlight the utility of this approach we use our method to detect leaks for two scenarios. The first scenario simulates a fluid leak from the storage formation into an above-zone monitoring interval. The second scenario simulates intra-reservoir migration between two compartments. We illustrate this method to detect fluid leakage in three different reservoirs with varying levels of geological and structural complexity. The proposed leakage detection method has three novelties: i) requires only readily-available data (injection and production rates), ii) accounts for fluid compressibility and boundary effects, and iii) in addition to

  20. Passive Acoustic Leak Detection for Sodium Cooled Fast Reactors Using Hidden Markov Models

    Science.gov (United States)

    Marklund, A. Riber; Kishore, S.; Prakash, V.; Rajan, K. K.; Michel, F.

    2016-06-01

    Acoustic leak detection for steam generators of sodium fast reactors have been an active research topic since the early 1970s and several methods have been tested over the years. Inspired by its success in the field of automatic speech recognition, we here apply hidden Markov models (HMM) in combination with Gaussian mixture models (GMM) to the problem. To achieve this, we propose a new feature calculation scheme, based on the temporal evolution of the power spectral density (PSD) of the signal. Using acoustic signals recorded during steam/water injection experiments done at the Indira Gandhi Centre for Atomic Research (IGCAR), the proposed method is tested. We perform parametric studies on the HMM+GMM model size and demonstrate that the proposed method a) performs well without a priori knowledge of injection noise, b) can incorporate several noise models and c) has an output distribution that simplifies false alarm rate control.

  1. Passive acoustic leak detection for sodium cooled fast reactors using hidden Markov models

    Energy Technology Data Exchange (ETDEWEB)

    Riber Marklund, A. [CEA, Cadarache, DEN/DTN/STCP/LIET, Batiment 202, 13108 St Paul-lez-Durance, (France); Kishore, S. [Fast Reactor Technology Group of IGCAR, (India); Prakash, V. [Vibrations Diagnostics Division, Fast Reactor Technology Group of IGCAR, (India); Rajan, K.K. [Fast Reactor Technology Group and Engineering Services Group of IGCAR, (India)

    2015-07-01

    Acoustic leak detection for steam generators of sodium fast reactors have been an active research topic since the early 1970's and several methods have been tested over the years. Inspired by its success in the field of automatic speech recognition, we here apply hidden Markov models (HMM) in combination with Gaussian mixture models (GMM) to the problem. To achieve this, we propose a new feature calculation scheme, based on the temporal evolution of the power spectral density (PSD) of the signal. Using acoustic signals recorded during steam/water injection experiments done at the Indira Gandhi Centre for Atomic Research (IGCAR), the proposed method is tested. We perform parametric studies on the HMM+GMM model size and demonstrate that the proposed method a) performs well without a priori knowledge of injection noise, b) can incorporate several noise models and c) has an output distribution that simplifies false alarm rate control. (authors)

  2. Applications of a morphological scene change detection (MSCD) for visual leak and failure identification in process and chemical engineering

    Science.gov (United States)

    Tickle, Andrew J.; Harvey, Paul K.; Smith, Jeremy S.

    2010-10-01

    Morphological Scene Change Detection (MSCD) is a process typically tasked at detecting relevant changes in a guarded environment for security applications. This can be implemented on a Field Programmable Gate Array (FPGA) by a combination of binary differences based around exclusive-OR (XOR) gates, mathematical morphology and a crucial threshold setting. The additional ability to set up the system in virtually any location due to the FPGA makes it ideal for insertion into an autonomous mobile robot for patrol duties. However, security is not the only potential of this robust algorithm. This paper details how such a system can be used for the detection of leaks in piping for use in the process and chemical industries and could be deployed as stated in the above manner. The test substance in this work was water, which was pumped either as a liquid or as low pressure steam through a simple pipe configuration with holes at set points to simulate the leaks. These holes were situated randomly at either the center of a pipe (in order to simulate an impact to it) or at a joint or corner (to simulate a failed weld). Imagery of the resultant leaks, which were visualised as drips or the accumulation of steam, which where analysed using MATLAB to determine their pixel volume in order to calibrate the trigger for the MSCD. The triggering mechanism is adaptive to make it possible in theory for the type of leak to be determined by the number of pixels in the threshold of the image and a numerical output signal to state which of the leak situations is being observed. The system was designed using the DSP Builder package from Altera so that its graphical nature is easily comprehensible to the non-embedded system designer. Furthermore, all the data from the DSP Builder simulation underwent verification against MATLAB comparisons using the image processing toolbox in order to validate the results.

  3. Flight Testing of an Advanced Airborne Natural Gas Leak Detection System

    Energy Technology Data Exchange (ETDEWEB)

    Dawn Lenz; Raymond T. Lines; Darryl Murdock; Jeffrey Owen; Steven Stearns; Michael Stoogenke

    2005-10-01

    ITT Industries Space Systems Division (Space Systems) has developed an airborne natural gas leak detection system designed to detect, image, quantify, and precisely locate leaks from natural gas transmission pipelines. This system is called the Airborne Natural Gas Emission Lidar (ANGEL) system. The ANGEL system uses a highly sensitive differential absorption Lidar technology to remotely detect pipeline leaks. The ANGEL System is operated from a fixed wing aircraft and includes automatic scanning, pointing system, and pilot guidance systems. During a pipeline inspection, the ANGEL system aircraft flies at an elevation of 1000 feet above the ground at speeds of between 100 and 150 mph. Under this contract with DOE/NETL, Space Systems was funded to integrate the ANGEL sensor into a test aircraft and conduct a series of flight tests over a variety of test targets including simulated natural gas pipeline leaks. Following early tests in upstate New York in the summer of 2004, the ANGEL system was deployed to Casper, Wyoming to participate in a set of DOE-sponsored field tests at the Rocky Mountain Oilfield Testing Center (RMOTC). At RMOTC the Space Systems team completed integration of the system and flew an operational system for the first time. The ANGEL system flew 2 missions/day for the duration for the 5-day test. Over the course of the week the ANGEL System detected leaks ranging from 100 to 5,000 scfh.

  4. Conceptual design report for the project to install leak detection in FAST-FT-534/548/549

    Energy Technology Data Exchange (ETDEWEB)

    Galloway, K.J.

    1992-07-01

    This report provides conceptual designs and design recommendations for installing secondary containment and leak detection systems for three sumps at the Fluorinel and Storage Facility (FAST), CPP-666. The FAST facility is located at the Idaho Chemical Processing Plant (ICPP) at the Idaho National Engineering Laboratory (INEL). The three sumps receive various materials from the FAST water treatment process. This project involves sump upgrades to meet appropriate environmental requirements. The steps include: providing sump modifications or designs for the installation of leak chases and/or leakage accumulation, coating the sump concrete with a chemical resistant sealant (except for sump VES-FT-534 which is already lined with stainless steel) to act as secondary containment, lining the sumps with a primary containment system, and providing a means to detect and remove primary containment leakage that may occur.

  5. Air Conditioning Compressor Air Leak Detection by Image Processing Techniques for Industrial Applications

    Directory of Open Access Journals (Sweden)

    Pookongchai Kritsada

    2015-01-01

    Full Text Available This paper presents method to detect air leakage of an air conditioning compressor using image processing techniques. Quality of air conditioning compressor should not have air leakage. To test an air conditioning compressor leak, air is pumped into a compressor and then submerged into the water tank. If air bubble occurs at surface of the air conditioning compressor, that leakage compressor must be returned for maintenance. In this work a new method to detect leakage and search leakage point with high accuracy, fast, and precise processes was proposed. In a preprocessing procedure to detect the air bubbles, threshold and median filter techniques have been used. Connected component labeling technique is used to detect the air bubbles while blob analysis is searching technique to analyze group of the air bubbles in sequential images. The experiments are tested with proposed algorithm to determine the leakage point of an air conditioning compressor. The location of the leakage point was presented as coordinated point. The results demonstrated that leakage point during process could be accurately detected. The estimation point had error less than 5% compared to the real leakage point.

  6. Posttraumatic lumbar cerebrospinal fluid leak: detection by retrograde In-111-DTPA myeloscintography

    Energy Technology Data Exchange (ETDEWEB)

    Colletti, P.M.; Siegel, M.E.

    1981-09-01

    A case of lumbar cerebrospinal fluid (CSF) extravasation with an unsuspected traumatic meningocele after a gunshot wound was detected by means of retrograde myeloscintography using isobaric In-111-DTPA. Our experience and a review of the literature have provided evidence retrograde myeloscintography may be useful for detecting and delineating significant traumatic thoracic and lumbar CSF leaks.

  7. EXTENDED PERFORMANCE HANDHELD AND MOBILE SENSORS FOR REMOTE DETECTION OF NATURAL GAS LEAKS

    Energy Technology Data Exchange (ETDEWEB)

    Michael B. Frish; B. David Green; Richard T. Wainner; Francesca Scire-Scappuzzo; Paul Cataldi; Matthew C. Laderer

    2005-05-01

    This report summarizes work performed by Physical Sciences Inc. (PSI) to advance the state-of-the-art of surveying for leaks of natural gas from transmission and distribution pipelines. The principal project goal was to develop means of deploying on an automotive platform an improved version of the handheld laser-based standoff natural gas leak detector previously developed by PSI and known as the Remote Methane Leak Detector or RMLD. A laser beam which interrogates the air for methane is projected from a spinning turret mounted upon a van. As the van travels forward, the laser beam scans an arc to the front and sides of the van so as to survey across streets and to building walls from a moving vehicle. When excess methane is detected within the arc, an alarm is activated. In this project, we built and tested a prototype Mobile RMLD (MRMLD) intended to provide lateral coverage of 10 m and one lateral scan for every meter of forward motion at forward speeds up to 10 m/s. Using advanced detection algorithms developed as part of this project, the early prototype MRMLD, installed on the back of a truck, readily detected simulated gas leaks of 50 liters per hour. As a supplement to the originally planned project, PSI also participated in a DoE demonstration of several gas leak detection systems at the Rocky Mountain Oilfield Testing Center (RMOTC) during September 2004. Using a handheld RMLD upgraded with the advanced detection algorithms developed in this project, from within a moving vehicle we readily detected leaks created along the 7.4 mile route of a virtual gas transmission pipeline.

  8. Optimal Sensor Placement for Leak Location in Water Distribution Networks Using Genetic Algorithms

    OpenAIRE

    Casillas, Myrna V.; Puig, Vicenc; Garza-Castanon, Luis E.; Rosich, Albert

    2013-01-01

    This paper proposes a new sensor placement approach for leak location in water distribution networks (WDNs). The sensor placement problem is formulated as an integer optimization problem. The optimization criterion consists in minimizing the number of non-isolable leaks according to the isolability criteria introduced. Because of the large size and non-linear integer nature of the resulting optimization problem, genetic algorithms (GAs) are used as the solution approach. The obtained results ...

  9. Development of a low cost unmanned aircraft system for atmospheric carbon dioxide leak detection

    Science.gov (United States)

    Mitchell, Taylor Austin

    Carbon sequestration, the storage of carbon dioxide gas underground, has the potential to reduce global warming by removing a greenhouse gas from the atmosphere. These storage sites, however, must first be monitored to detect if carbon dioxide is leaking back out to the atmosphere. As an alternative to traditional large ground-based sensor networks to monitor CO2 levels for leaks, unmanned aircraft offer the potential to perform in-situ atmospheric leak detection over large areas for a fraction of the cost. This project developed a proof-of-concept sensor system to map relative carbon dioxide levels to detect potential leaks. The sensor system included a Sensair K-30 FR CO2 sensor, GPS, and altimeter connected an Arduino microcontroller which logged data to an onboard SD card. Ground tests were performed to verify and calibrate the system including wind tunnel tests to determine the optimal configuration of the system for the quickest response time (4-8 seconds based upon flowrate). Tests were then conducted over a controlled release of CO 2 in addition to over controlled rangeland fires which released carbon dioxide over a large area as would be expected from a carbon sequestration source. 3D maps of carbon dioxide were developed from the system telemetry that clearly illustrated increased CO2 levels from the fires. These tests demonstrated the system's ability to detect increased carbon dioxide concentrations in the atmosphere.

  10. Functionalized multi-walled carbon nanotube based sensors for distributed methane leak detection

    Science.gov (United States)

    This paper presents a highly sensitive, energy efficient and low-cost distributed methane (CH4) sensor system (DMSS) for continuous monitoring, detection and localization of CH4 leaks in natural gas infrastructure such as transmission and distribution pipelines, wells, and produc...

  11. New methods for leaks detection and localisation using acoustic emission; Nouvelles methodes de detection et de localisation de fuites par emission acoustique

    Energy Technology Data Exchange (ETDEWEB)

    Boulanger, P.

    1993-12-08

    Real time monitoring of Pressurized Water nuclear Reactor secondary coolant system tends to integrate digital processing machines. In this context, the method of acoustic emission seems to exhibit good performances. Its principle is based on passive listening of noises emitted by local micro-displacements inside a material under stress which propagate as elastic waves. The lack of a priori knowledge on leak signals leads us to go deeper into understanding flow induced noise generation. Our studies are conducted using a simple leak model depending on the geometry and the king of flow inside the slit. Detection and localization problems are formulated according to the maximum likelihood principle. For detection, the methods using a indicator of similarity (correlation, higher order correlation) seems to give better results than classical ones (rms value, envelope, filter banks). For leaks location, a large panel of classical (generalized inter-correlation) and innovative (convolution, adaptative, higher order statistics) methods of time delay estimation are presented. The last part deals with the applications of higher order statistics. The analysis of higher order estimators of a non linear non Gaussian stochastic process family, the improvement of non linear prediction performances and the optimal-order choice problem are addressed in simple analytic cases. At last, possible applications to leak signals analysis are pointed out. (authors).264 refs., 7 annexes.

  12. High Temperature Humidity Sensor for Detection of Leak Through Slits and Cracks in Pressurized Nuclear Power Reactor Pipes

    Directory of Open Access Journals (Sweden)

    Debdulal Saha

    2007-03-01

    Full Text Available The leak before break (LBB concept is well known to nuclear power reactor. The problem is common to water power reactor. This is based on the premise that a detectable leak will develop before catastrophic break occurs. The main purpose of the present study is to develop tape cast MgCr2O4+35mole% TiO2 and gel cast g-Al2O3 humidity sensor for use in LBB applications at 3000C. The material capacitance varies with transient injection of water vapour adsorption. In actual plant, the sensors are placed on a steam pipe surrounded by heat insulation. The pipe unites the nuclear reactor and power generator. The analysis of humidity distribution in the annulus is calculated assuring leak rate 0.1gpm in a 30 m long tube. In this paper, analysis is done on the basis of the two types of sensor using AC frequency. Performance characteristics are observed for the LLB application.

  13. Research and development of a high-temperature helium-leak detection system (joint research). Part 1 survey on leakage events and current leak detection technology

    Energy Technology Data Exchange (ETDEWEB)

    Sakaba, Nariaki; Nakazawa, Toshio; Kawasaki, Kozo [Japan Atomic Energy Research Inst., Oarai, Ibaraki (Japan). Oarai Research Establishment; Urakami, Masao; Saisyu, Sadanori [Japan Atomic Power Co., Tokyo (Japan)

    2003-03-01

    In High Temperature Gas-cooled Reactors (HTGR), the detection of leakage of helium at an early stage is very important for the safety and stability of operations. Since helium is a colourless gas, it is generally difficult to identify the location and the amount of leakage when very little leakage has occurred. The purpose of this R and D is to develop a helium leak detection system for the high temperature environment appropriate to the HTGR. As the first step in the development, this paper describes the result of surveying leakage events at nuclear facilities inside and outside Japan and current gas leakage detection technology to adapt optical-fibre detection technology to HTGRs. (author)

  14. Leak detection in gas pipeline by acoustic and signal processing - A review

    Science.gov (United States)

    Adnan, N. F.; Ghazali, M. F.; Amin, M. M.; Hamat, A. M. A.

    2015-12-01

    The pipeline system is the most important part in media transport in order to deliver fluid to another station. The weak maintenance and poor safety will contribute to financial losses in term of fluid waste and environmental impacts. There are many classifications of techniques to make it easier to show their specific method and application. This paper's discussion about gas leak detection in pipeline system using acoustic method will be presented in this paper. The wave propagation in the pipeline is a key parameter in acoustic method when the leak occurs and the pressure balance of the pipe will generated by the friction between wall in the pipe. The signal processing is used to decompose the raw signal and show in time- frequency. Findings based on the acoustic method can be used for comparative study in the future. Acoustic signal and HHT is the best method to detect leak in gas pipelines. More experiments and simulation need to be carried out to get the fast result of leaking and estimation of their location.

  15. A Fiber-Optic Sensor for Leak Detection in a Space Environment

    Science.gov (United States)

    Sinko, John E.; Korman, Valentin; Hendrickson, Adam; Polzin, Kurt A.

    2009-01-01

    A miniature fiber-optic, laser-based, interferometric leak detector is presented for application as a means to detect on-orbit gas leaks. The sensor employs a fiber-coupled modified Michelson interferometer to detect gas leaks by measuring an increase in gas density in the sensing region. Monitoring changes in the fringe pattern output by the interferometer allows for direct measurement of the gas density in the sensing region and, under the assumption of an equation of state, this can be used to obtain a pressure measurement. Measurements obtained over a pressure range from 20 mtorr to 760 torr using a prototypical interferometer on working gases of air, nitrogen, argon, and helium generally exhibit agreement with a theoretical prediction of the pressure increase required before an interference fringe completely moves over the detector. Additional measurements performed on various gases demonstrate the range of detectable species, measuring sub-torr pressure changes in the process. A high-fidelity measurement places the ultimate pressure resolution for this particular sensor configuration in the 10 mtorr range. Time-resolved data prove the capability of this sensor to detect fast gas flow phenomena associated with transients and pressure waves.

  16. Leaks in pipe networks

    Science.gov (United States)

    Pudar, Ranko S.; Liggett, James A.

    1992-01-01

    Leak detection in water-distribution systems can be accomplished by solving an inverse problem using measurements of pressure and/or flow. The problem is formulated with equivalent orifice areas of possible leaks as the unknowns. Minimization of the difference between measured and calculated heads produces a solution for the areas. The quality of the result depends on number and location of the measurements. A sensitivity matrix is key to deciding where to make measurements. Both location and magnitude of leaks are sensitive to the quantity and quality of pressure measurements and to how well the pipe friction parameters are known. The overdetermined problem (more measurements than suspected leaks) gives the best results, but some information can be derived from the underdetermined problem. The variance of leak areas, based on the quality of system characteristics and pressure data, indicates the likely accuracy of the results. The method will not substitute for more traditional leak surveys but can serve as a guide and supplement.

  17. Advanced conceptual design report: T Plant secondary containment and leak detection upgrades. Project W-259

    Energy Technology Data Exchange (ETDEWEB)

    Hookfin, J.D.

    1995-05-12

    The T Plant facilities in the 200-West Area of the Hanford site were constructed in the early 1940s to produce nuclear materials in support of national defense activities. T Plant includes the 271-T facility, the 221-T facility, and several support facilities (eg, 2706-T), utilities, and tanks/piping systems. T Plant has been recommended as the primary interim decontamination facility for the Hanford site. Project W-259 will provide capital upgrades to the T Plant facilities to comply with Federal and State of Washington environmental regulations for secondary containment and leak detection. This document provides an advanced conceptual design concept that complies with functional requirements for the T Plant Secondary Containment and Leak Detection upgrades.

  18. Acoustic emission method to detect cracks and leaks of the nuclear steam supply system

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Sung Hoh; Jang, Woo Hyun; Han, Sang Joon [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1993-10-01

    The work on using Acoustic Emission (AE) method for continuous surveillance of reactor pressure boundaries of nuclear power plants to detect crack or leak of coolant and to evaluate the severity of the flaws is in progress, and has been studied in this report. Several tests and analyses have been accomplished, and the technique to identify the acoustic signal produced by flaw growth, to locate the acoustic source, to relate the signal level to the crack growth rate and leak rate, and to identify the type of flaws is proved to be feasible. There have been efforts to describe the flaw theoretically using fracture mechanics that are helpful in the flaw evaluation. Instrumentations systems to implement the AE technique are surveyed, and the result shows that the current AE detection systems in domestic nuclear power plants can be improved by adopting the up-to-date accomplishments in AE methods. 47 figs., 17 refs. (Author).

  19. Emergency membrane contactor based absorption system for ammonia leaks in water treatment plants.

    Science.gov (United States)

    Shao, Jiahui; Fang, Xuliang; He, Yiliang; Jin, Qiang

    2008-01-01

    Abstract Because of the suspected health risks of trihalomethanes (THMs), more and more water treatment plants have replaced traditional chlorine disinfection process with chloramines but often without the proper absorption system installed in the case of ammonia leaks in the storage room. A pilot plant membrane absorption system was developed and installed in a water treatment plant for this purpose. Experimentally determined contact angle, surface tension, and corrosion tests indicated that the sulfuric acid was the proper choice as the absorbent for leaking ammonia using polypropylene hollow fiber membrane contactor. Effects of several operating conditions on the mass transfer coefficient, ammonia absorption, and removal efficiency were examined, including the liquid concentration, liquid velocity, and feed gas concentration. Under the operation conditions investigated, the gas absorption efficiency over 99.9% was achieved. This indicated that the designed pilot plant membrane absorption system was effective to absorb the leaking ammonia in the model storage room. The removal rate of the ammonia in the model storage room was also experimentally and theoretically found to be primarily determined by the ammonia suction flow rate from the ammonia storage room to the membrane contactor. The ammonia removal rate of 99.9% was expected to be achieved within 1.3 h at the ammonia gas flow rate of 500 m3/h. The success of the pilot plant membrane absorption system developed in this study illustrated the potential of this technology for ammonia leaks in water treatment plant, also paved the way towards a larger scale application.

  20. CALM: cascading system with leaking detection mechanism for medical image segmentation

    Science.gov (United States)

    Liu, Jiang; Lim, Joo Hwee; Li, Huiqi

    2008-03-01

    Medical image segmentation is a challenging process due to possible image over-segmentation and under-segmentation (leaking). The CALM medical image segmentation system is constructed with an innovative scheme that cascades threshold level-set and region-growing segmentation algorithms using Union and Intersection set operators. These set operators help to balance the over-segmentation rate and under-segmentation rate of the system respectively. While adjusting the curvature scalar parameter in the threshold level-set algorithm, we observe that the abrupt change in the size of the segmented areas coincides with the occurrences of possible leaking. Instead of randomly choose a value or use the system default curvature scalar values, this observation prompts us to use the following formula in CALM to automatically decide the optimal curvature values γ to prevent the occurrence of leaking : δ2S/δγ2 >= M, where S is the size of the segmented area and M is a large positive number. Motivated for potential applications in organ transplant and analysis, the CALM system is tested on the segmentation of the kidney regions from the Magnetic Resonance images taken from the National University Hospital of Singapore. Due to the nature of MR imaging, low-contrast, weak edges and overlapping regions of adjacent organs at kidney boundaries are frequently seen in the datasets and hence kidney segmentation is prone to leaking. The kidney segmentation accuracy rate achieved by CALM is 22% better compared with those achieved by the component algorithms or the system without leaking detection mechanism. CALM is easy-to-implement and can be applied to many applications besides kidney segmentation.

  1. Likelihood of Brine and CO2 Leak Detection using Magnetotellurics and Electrical Resistivity Tomography Methods

    Energy Technology Data Exchange (ETDEWEB)

    Yang, X. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Buscheck, T. A. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Mansoor, K. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Carroll, S. A. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2017-09-11

    The US DOE National Risk Assessment Partnership (NRAP), funded through the Office of Fossil Energy and NETL, is developing methods to evaluate the effectiveness of monitoring techniques to detect brine and CO2 leakage from legacy wells into underground sources of drinking water (USDW) overlying a CO2 storage reservoir. As part of the NRAP Strategic Monitoring group, we have generated 140 simulations of aquifer impact data based on the Kimberlina site in California’s southern San Joaquin Basin, Kimberlina Rev. 1.1. CO2 buoyancy allows some of the stored CO2 to reach shallower permeable zones and is detectable with surface geophysical sensors. We are using this simulated data set to evaluate effectiveness of electrical resistivity tomography (ERT) and magnetotellurics (MT) for leak detection. The evaluation of additional monitoring methods such as pressure, seismic and gravity is underway through a multi-lab collaboration.

  2. Assuring asset integrity through improving the accuracy of leakage source identification of a permanently installed subsea leak detection system using artificial neural networks

    OpenAIRE

    Poungkrajorn, Tawan

    2015-01-01

    Master's thesis in Offshore technology : industrial asset management Environmental concerns and regulatory controls for oil and gas exploration and production activities have been increasing with the prospecting of deep-water fields and sensitive areas, such as the artic seas. To stop any incidents developing into critical events, subsea leak detection systems are required for a fast, cost-effective, and reasonable accurate method to not only detect the leakage substance (in this case meth...

  3. Low-cost multispectral vegetation imaging system for detecting leaking CO₂ gas.

    Science.gov (United States)

    Hogan, Justin A; Shaw, Joseph A; Lawrence, Rick L; Larimer, Randal M

    2012-02-01

    As a component of a multisensor approach to monitoring carbon sequestration sites for possible leaks of the CO₂ gas from underground reservoirs, a low-cost multispectral imaging system has been developed for indirect detection of gas leaks through observations of the resulting stress in overlying vegetation. The imager employs front-end optics designed to provide a full 50° field of view with a small, low-cost CMOS detector, while still maintaining quasi-collimated light through the angle-dependent interference filters used to define the spectral bands. Red and near-infrared vegetation reflectances are used to compute the normalized difference vegetation index (NDVI) and spatial and temporal patterns are analyzed statistically to identify regions of anomalous stress, which are then flagged for closer inspection with in-situ CO₂ sensors. The system is entirely self-contained with an onboard compact computer and is housed in a weather-proof housing to enable extended outdoor deployment.

  4. Development of a Free-Swimming Acoustic Tool for Liquid Pipeline Leak Detection Including Evaluation for Natural Gas Pipeline Applications

    Science.gov (United States)

    2010-08-01

    Significant financial and environmental consequences often result from line leakage of oil product pipelines. Product can escape into the surrounding soil as even the smallest leak can lead to rupture of the pipeline. From a health perspective, water...

  5. SSME leak detection feasibility investigation by utilization of infrared sensor technology

    Science.gov (United States)

    Shohadaee, Ahmad A.; Crawford, Roger A.

    1990-01-01

    This investigation examined the potential of using state-of-the-art technology of infrared (IR) thermal imaging systems combined with computer, digital image processing and expert systems for Space Shuttle Main Engines (SSME) propellant path peak detection as an early warning system of imminent engine failure. A low-cost, laboratory experiment was devised and an experimental approach was established. The system was installed, checked out, and data were successfully acquired demonstrating the proof-of-concept. The conclusion from this investigation is that both numerical and experimental results indicate that the leak detection by using infrared sensor technology proved to be feasible for a rocket engine health monitoring system.

  6. Optimal sensor placement for leak location in water distribution networks using genetic algorithms.

    Science.gov (United States)

    Casillas, Myrna V; Puig, Vicenç; Garza-Castañón, Luis E; Rosich, Albert

    2013-11-04

    This paper proposes a new sensor placement approach for leak location in water distribution networks (WDNs). The sensor placement problem is formulated as an integer optimization problem. The optimization criterion consists in minimizing the number of non-isolable leaks according to the isolability criteria introduced. Because of the large size and non-linear integer nature of the resulting optimization problem, genetic algorithms (GAs) are used as the solution approach. The obtained results are compared with a semi-exhaustive search method with higher computational effort, proving that GA allows one to find near-optimal solutions with less computational load. Moreover, three ways of increasing the robustness of the GA-based sensor placement method have been proposed using a time horizon analysis, a distance-based scoring and considering different leaks sizes. A great advantage of the proposed methodology is that it does not depend on the isolation method chosen by the user, as long as it is based on leak sensitivity analysis. Experiments in two networks allow us to evaluate the performance of the proposed approach.

  7. Modeling of Hydrodynamic Processes at a Large Leak of Water into Sodium in the Fast Reactor Coolant Circuit

    OpenAIRE

    Perevoznikov, Sergey; Shvetsov, Yuriy; Kamayev, Aleksey; Pakhomov, Ilia; Borisov, Viacheslav; Pazin, Gennadiy; Mirzeabasov, Oleg; Korzun, Olga

    2016-01-01

    In this paper, we describe a physicomathematical model of the processes that occur in a sodium circuit with a variable flow cross-section in the case of a water leak into sodium. The application area for this technique includes the possibility of analyzing consequences of this leak as applied to sodium–water steam generators in fast neutron reactors. Hydrodynamic processes that occur in sodium circuits in the event of a water leak are described within the framework of a one-dimensional therma...

  8. Intelligent leak detection system for oil pipelines; Sistema inteligente para deteccao de vazamentos em dutos de petroleo

    Energy Technology Data Exchange (ETDEWEB)

    Freitas, Ricardo Dantas Gadelha de [PETROBRAS S.A., Rio de Janeiro, RJ (Brazil)

    2003-07-01

    One of the most challenging tasks in an oil field is implementation of a software-based leak detection system on a multi-phase flow pipeline. This paper will discuss implementation of a leak detection system in a particular oil field using state-of-the-art signal processing techniques to apply to the data collected in a oil pipeline. This leak detection system is still in development and uses a more practical approach to the problem than traditional methods and was implemented on a PC under the Windows operating system. Windowing, joint time-frequency analysis and wavelets were considered to develop methods of detecting leaks by watching for the wavefront. The idea behind these techniques is to cut the signal of interest into several parts and then analyze the parts separately. It is impossible to know the exact frequency and the exact time of occurrence of the leak frequency in a signal. In other words, a leak signal can simply not be represented as a point in the time-frequency space. It is very important how one cuts the signal to implement the analysis. The wavelet transform or wavelet analysis is probably the most recent solution to overcome the shortcomings of the Fourier transform. So, this paper shows some tests and how these techniques are being implementing during the development of the system. (author)

  9. Application of Morphological Segmentation to Leaking Defect Detection in Sewer Pipelines

    Directory of Open Access Journals (Sweden)

    Tung-Ching Su

    2014-05-01

    Full Text Available As one of major underground pipelines, sewerage is an important infrastructure in any modern city. The most common problem occurring in sewerage is leaking, whose position and failure level is typically identified through closed circuit television (CCTV inspection in order to facilitate rehabilitation process. This paper proposes a novel method of computer vision, morphological segmentation based on edge detection (MSED, to assist inspectors in detecting pipeline defects in CCTV inspection images. In addition to MSED, other mathematical morphology-based image segmentation methods, including opening top-hat operation (OTHO and closing bottom-hat operation (CBHO, were also applied to the defect detection in vitrified clay sewer pipelines. The CCTV inspection images of the sewer system in the 9th district, Taichung City, Taiwan were selected as the experimental materials. The segmentation results demonstrate that MSED and OTHO are useful for the detection of cracks and open joints, respectively, which are the typical leakage defects found in sewer pipelines.

  10. Application of morphological segmentation to leaking defect detection in sewer pipelines.

    Science.gov (United States)

    Su, Tung-Ching; Yang, Ming-Der

    2014-05-16

    As one of major underground pipelines, sewerage is an important infrastructure in any modern city. The most common problem occurring in sewerage is leaking, whose position and failure level is typically identified through closed circuit television (CCTV) inspection in order to facilitate rehabilitation process. This paper proposes a novel method of computer vision, morphological segmentation based on edge detection (MSED), to assist inspectors in detecting pipeline defects in CCTV inspection images. In addition to MSED, other mathematical morphology-based image segmentation methods, including opening top-hat operation (OTHO) and closing bottom-hat operation (CBHO), were also applied to the defect detection in vitrified clay sewer pipelines. The CCTV inspection images of the sewer system in the 9th district, Taichung City, Taiwan were selected as the experimental materials. The segmentation results demonstrate that MSED and OTHO are useful for the detection of cracks and open joints, respectively, which are the typical leakage defects found in sewer pipelines.

  11. Validation of the Low-Range Differential Pressure (LRDP) Leak Detection System for Small Leaks in Bulk Fuel Tanks

    Science.gov (United States)

    1998-01-01

    gal/h [TLR - CMDL (A2/A1)] > 0.1 or 0.1 for [TLR - CMDL (A2/A1)] < 0.1 PD – % 95% PFA - % < 5% *There may be more than one threshold...specification for system operation; TLR = target leak rate. **Define MDL and CMDL = MDL/2 for A1; S for A1; and A1...0.2 Threshold, C – gal/h [TLR-( CMDL /n0.5) (A2/A1)] > 0.1 such that 1 < n < 12 or 0.1 for [TLR- ( CMDL /n0.5) (A2/A1)] < 0.1 PD – % 95

  12. NRC Job Code V6060: Extended in-situ and real time monitoring. Task 4: Detection and monitoring of leaks at nuclear power plants external to structures

    Energy Technology Data Exchange (ETDEWEB)

    Sheen, S. H. (Nuclear Engineering Division)

    2012-08-01

    In support of Task 4 of the NRC study on compliance with 10 CFR part 20.1406, minimization of contamination, Argonne National Laboratory (ANL) conducted a one-year scoping study, in concert with a parallel study performed by NRC/NRR staff, on monitoring for leaks at nuclear power plants (NPPs) external to structures. The objective of this task-4 study is to identify and assess those sensors and monitoring techniques for early detection of abnormal radioactive releases from the engineered facility structures, systems and components (SSCs) to the surrounding underground environment in existing NPPs and planned new reactors. As such, methods of interest include: (1) detection of anomalous water content of soils surrounding SSCs, (2) radionuclides contained in the leaking water, and (3) secondary signals such as temperature. ANL work scope includes mainly to (1) identify, in concert with the nuclear industry, the sensors and techniques that have most promise to detect radionuclides and/or associated chemical releases from SSCs of existing NPPs and (2) review and provide comments on the results of the NRC/NRR staff scoping study to identify candidate technologies. This report constitutes the ANL deliverable of the task-4 study. It covers a survey of sensor technologies and leak detection methods currently applied to leak monitoring at NPPs. The survey also provides a technology evaluation that identifies their strength and deficiency based on their detection speed, sensitivity, range and reliability. Emerging advanced technologies that are potentially capable of locating releases, identifying the radionuclides, and estimating their concentrations and distributions are also included in the report along with suggestions of required further research and development.

  13. Designing a reliable leak bio-detection system for natural gas pipelines.

    Science.gov (United States)

    Batzias, F A; Siontorou, C G; Spanidis, P-M P

    2011-02-15

    Monitoring of natural gas (NG) pipelines is an important task for economical/safety operation, loss prevention and environmental protection. Timely and reliable leak detection of gas pipeline, therefore, plays a key role in the overall integrity management for the pipeline system. Owing to the various limitations of the currently available techniques and the surveillance area that needs to be covered, the research on new detector systems is still thriving. Biosensors are worldwide considered as a niche technology in the environmental market, since they afford the desired detector capabilities at low cost, provided they have been properly designed/developed and rationally placed/networked/maintained by the aid of operational research techniques. This paper addresses NG leakage surveillance through a robust cooperative/synergistic scheme between biosensors and conventional detector systems; the network is validated in situ and optimized in order to provide reliable information at the required granularity level. The proposed scheme is substantiated through a knowledge based approach and relies on Fuzzy Multicriteria Analysis (FMCA), for selecting the best biosensor design that suits both, the target analyte and the operational micro-environment. This approach is illustrated in the design of leak surveying over a pipeline network in Greece. Copyright © 2010 Elsevier B.V. All rights reserved.

  14. LIBS Sensor for Sub-surface CO2 Leak Detection in Carbon Sequestration

    Directory of Open Access Journals (Sweden)

    Jinesh JAIN

    2017-07-01

    Full Text Available Monitoring carbon sequestration poses numerous challenges to the sensor community. For example, the subsurface environment is notoriously harsh, with large potential mechanical, thermal, and chemical stresses, making long-term stability and survival a challenge to any potential in situ monitoring method. Laser induced breakdown spectroscopy (LIBS has been demonstrated as a promising technology for chemical monitoring of harsh environments and hard to reach places. LIBS has a real- time monitoring capability and can be used for the elemental and isotopic analysis of solid, liquid, and gas samples. The flexibility of the probe design and the use of fiber- optics has made LIBS particularly suited for remote measurements. The paper focuses on developing a LIBS instrument for downhole high-pressure, high-temperature brine experiments, where CO2 leakage could result in changes in the trace mineral composition of an aquifer. The progress in fabricating a compact, robust, and simple LIBS sensor for widespread subsurface leak detection is presented.

  15. The detection of carbon dioxide leaks using quasi-tomographic laser absorption spectroscopy measurements in variable wind

    Science.gov (United States)

    Levine, Zachary H.; Pintar, Adam L.; Dobler, Jeremy T.; Blume, Nathan; Braun, Michael; Scott Zaccheo, T.; Pernini, Timothy G.

    2016-01-01

    Laser absorption spectroscopy (LAS) has been used over the last several decades for the measurement of trace gasses in the atmosphere. For over a decade, LAS measurements from multiple sources and tens of retroreflectors have been combined with sparse-sample tomography methods to estimate the 2-D distribution of trace gas concentrations and underlying fluxes from point-like sources. In this work, we consider the ability of such a system to detect and estimate the position and rate of a single point leak which may arise as a failure mode for carbon dioxide storage. The leak is assumed to be at a constant rate giving rise to a plume with a concentration and distribution that depend on the wind velocity. We demonstrate the ability of our approach to detect a leak using numerical simulation and also present a preliminary measurement. PMID:27453761

  16. COST AND PERFORMANCE REPORT: INNOVATIVE ACOUSTIC SENSOR TECHNOLOGIES FOR LEAK DETECTION IN CHALLENGING PIPE TYPES

    Science.gov (United States)

    2016-12-30

    methodology known as the Sustainability Management System that will provide a computer modeling platform to track all military assets, including potable...excavation revealed that the leak was under the slab of a building. Further research and development is needed to address location of leaks that may be...underneath building slabs or other surface features. In an actual field application, the lateral and leak may be under a building. 8.6

  17. Highly precise atmospheric oxygen measurements as a tool to detect leaks of carbon dioxide from Carbon Capture and Storage sites

    NARCIS (Netherlands)

    van Leeuwen, Charlotte

    2015-01-01

    In Carbon Capture and Storage (CCS), carbon dioxide (CO2) from fossil fuel combustion is stored underground into a geological formation. Although the storage of CO2 is considered as safe, leakage to the atmosphere is an important concern and monitoring is necessary. Detecting and quantifying leaks

  18. Detection of CO2 leaks from carbon capture and storage sites with combined atmospheric CO2 and O-2 measurements

    NARCIS (Netherlands)

    van Leeuwen, Charlotte; Meijer, Harro A. J.

    2015-01-01

    This paper presents a transportable instrument that simultaneously measures the CO2 and (relative) O-2 concentration of the atmosphere with the purpose to aid in the detection of CO2 leaks from CCS sites. CO2 and O-2 are coupled in most processes on earth (e.g., photosynthesis, respiration and

  19. Modeling of Hydrodynamic Processes at a Large Leak of Water into Sodium in the Fast Reactor Coolant Circuit

    Directory of Open Access Journals (Sweden)

    Sergey Perevoznikov

    2016-10-01

    Full Text Available In this paper, we describe a physicomathematical model of the processes that occur in a sodium circuit with a variable flow cross-section in the case of a water leak into sodium. The application area for this technique includes the possibility of analyzing consequences of this leak as applied to sodium–water steam generators in fast neutron reactors. Hydrodynamic processes that occur in sodium circuits in the event of a water leak are described within the framework of a one-dimensional thermally nonequilibrium three-component gas–liquid flow model (sodium–hydrogen–sodium hydroxide. Consideration is given to the results of a mathematical modeling of experiments involving steam injection into the sodium loop of a circulation test facility. That was done by means of the computer code in which the proposed model had been implemented.

  20. Migration of BTEX and Biodegradation in Shallow Underground Water through Fuel Leak Simulation.

    Science.gov (United States)

    Cheng, Yaping; Chen, Yudao; Jiang, Yaping; Jiang, Lingzhi; Sun, Liqun; Li, Liuyue; Huang, Junyu

    2016-01-01

    To provide more reasonable references for remedying underground water, fuel leak was simulated by establishing an experimental model of a porous-aquifer sand tank with the same size as that of the actual tank and by monitoring the underground water. In the tank, traditional gasoline and ethyl alcohol gasoline were poured. This study was conducted to achieve better understanding of the migration and distribution of benzene, toluene, ethyl benzene, and xylene (BTEX), which are major pollutants in the underground water. Experimental results showed that, compared with conventional gasoline, the content peak of BTEX in the mixture of ethyl alcohol gasoline appeared later; BTEX migrated along the water flow direction horizontally and presented different pollution halos; BTEX also exhibited the highest content level at 45 cm depth; however, its content declined at the 30 and 15 cm depths vertically because of the vertical dispersion effect; the rise of underground water level increased the BTEX content, and the attenuation of BTEX content in underground water was related to the biodegradation in the sand tank, which mainly included biodegradation with oxygen, nitrate, and sulfate.

  1. A survey of existing and emerging technologies for external detection of liquid leaks at the Hanford Site

    Energy Technology Data Exchange (ETDEWEB)

    Lewis, R.E.; Teel, S.S.

    1994-10-01

    During the history of the Hanford Site, many structures were built that stored and transported liquids used for the production mission; some of these structures are still active. Active structures include underground storage tanks retention basins, and pipes and pipelines. Many of the liquids stored and transported in these structures are potentially hazardous to human health and the environment. Any leakage of liquids from active structures, has the added potential to mobilize contaminants in the unsaturated zone. Therefore, it is beneficial to monitor these structures for leaks. The purpose of tills report is to catalog existing and emerging technologies that have potential for the external monitoring of liquid leaks. The report will focus primarily on the needs at the Hanford Site tank farms that are located in the 200 Areas, but will also be relevant to other Hanford Site facilities. Leak detection systems, both external and internal, are currently used at some Hanford facilities. This report focuses on the detection of leaks as they migrate into the soils surrounding the facilities.

  2. Water cooling system leak proofing strategy for the Plasma Couette Experiment Upgrade (PCX-U)

    Science.gov (United States)

    Clark, Mike; Flanagan, Ken; Hernandez, Wilson; Jaeger, Austin; Laufman-Wollitzer, Lauren; Nikolau, Ethan; Tabbutt, Megan; Waleffe, Roger; Wallace, John; Xu, Yufan; Forest, Cary

    2016-10-01

    An improved system for water cooling several experimental components has been installed for the Plasma Couette Experiment Upgrade (PCX-U). The most important aspect of the upgrade was to cool the new SmCo permanent magnet cage array. Many methods of connecting water cooling pipes, tubes, and fittings were employed balancing several factors. These factors included ease of assembly/disassembly, reliability, operating pressure, operating temperature, chemical reactivity, and cost. The actions taken to develop the water cooling system will be discussed and illustrated. A focus will be made on sealing cooling water leaks from the inside out on small diameter metal passages (including extrusions, tubing, and fittings). These passages were located inside a vacuum environment, and only the ends of each passage were accessible to do the work. The vacuum vessel of PCX-U is a 1 meter diameter, 1 meter tall cylinder comprised of 0.25'' thick stainless steel. PCX-U has one removable end. Rings of SmCo magnets attached to a removable frame create a cusp field to contain the plasma and provide a resonance surface for the RF. This work is supported by the NSF.

  3. AIRBORNE, OPTICAL REMOTE SENSING OF METHANE AND ETHANE FOR NATURAL GAS PIPELINE LEAK DETECTION

    Energy Technology Data Exchange (ETDEWEB)

    Jerry Myers

    2003-11-12

    Ophir Corporation was awarded a contract by the U. S. Department of Energy, National Energy Technology Laboratory under the Project Title ''Airborne, Optical Remote Sensing of Methane and Ethane for Natural Gas Pipeline Leak Detection'' on October 14, 2002. This second six-month technical report summarizes the progress made towards defining, designing, and developing the hardware and software segments of the airborne, optical remote methane and ethane sensor. The most challenging task to date has been to identify a vendor capable of designing and developing a light source with the appropriate output wavelength and power. This report will document the work that has been done to identify design requirements, and potential vendors for the light source. Significant progress has also been made in characterizing the amount of light return available from a remote target at various distances from the light source. A great deal of time has been spent conducting laboratory and long-optical path target reflectance measurements. This is important since it helps to establish the overall optical output requirements for the sensor. It also reduces the relative uncertainty and risk associated with developing a custom light source. The data gathered from the optical path testing has been translated to the airborne transceiver design in such areas as: fiber coupling, optical detector selection, gas filters, and software analysis. Ophir will next, summarize the design progress of the transceiver hardware and software development. Finally, Ophir will discuss remaining project issues that may impact the success of the project.

  4. ISS Leak Detection and Astrophysics with Lobster-Eye X-Ray Detector Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Demonstrate angular resolution and sensitivity. Successful lab demonstration of ISS leak checking, using nitrogen, electron beam, and Lobster x-ray optic. 

  5. Development of a fiber-optic sensor for hydrogen leak detection

    Energy Technology Data Exchange (ETDEWEB)

    Benson, D.K.; Tracy, C.E. [National Renewable Energy Lab., Golden, CO (United States)

    1995-09-01

    The real and perceived risks of hydrogen fuel use, particularly in passenger vehicles, will require extensive safety precautions including hydrogen leak detection. Conventional hydrogen gas sensors require electrical wiring and may be too expensive for deployment in multiple locations within a vehicle. In this recently initiated project, we are attempting to develop a reversible, thin-film, chemochromic sensor that can be applied to the end of a polymer optical fiber. The presence of hydrogen gas causes the film to become darker. A light beam transmitted from a central instrument in the vehicle along the sensor fibers will be reflected from the ends of the fiber back to individual light detectors. A decrease in the reflected light signal will indicate the presence and concentration of hydrogen in the vicinity of the fiber sensor. The typical thin film sensor consists of a layer of transparent, amorphous tungsten oxide covered by a very thin reflective layer of palladium. When the sensor is exposed to hydrogen, a portion of the hydrogen is dissociated, diffuses through the palladium and reacts with the tungsten oxide to form a blue insertion compound, H{sub X}WO{sub 3}- When the hydrogen gas is no longer present, the hydrogen will diffuse out of the H{sub X}WO{sub 3} and oxidize at the palladium/air interface, restoring the tungsten oxide film and the light signal to normal. The principle of this detection scheme has already been demonstrated by scientists in Japan. However, the design of the sensor has not been optimized for speed of response nor tested for its hydrogen selectivity in the presence of hydrocarbon gases. The challenge of this project is to modify the basic sensor design to achieve the required rapid response and assure sufficient selectivity to avoid false readings.

  6. Proposed strategy for leak detection, monitoring, and mitigation (LDMM) during Hanford single-shell tank waste retrieval

    Energy Technology Data Exchange (ETDEWEB)

    Iwatate, D.F., Westinghouse Hanford

    1996-07-08

    This document proposes a strategy to address issues related to leakage from single-shell tanks (SSTs) during sluicing. A set of criteria are proposed to capture the relevant issues pertaining to leak detection, monitoring, and mitigation (LDMM), and allow DOE-RL, the Contractor, Ecology, and Hanford Stakeholders to reach consensus on allowable leakage volumes (ALVs). Technical studies and findings that support the proposed strategy, and ALV criteria, are summarized and referenced. This document specifically addresses LDMM for SSTs at Hanford, Washington.

  7. DETECTION OF HISTORICAL PIPELINE LEAK PLUMES USING NON-INTRUSIVE SURFACE-BASED GEOPHYSICAL TECHNIQUES AT THE HANFORD NUCLEAR SITE WASHINGTON USA

    Energy Technology Data Exchange (ETDEWEB)

    SKORSKA MB; FINK JB; RUCKER DF; LEVITT MT

    2010-12-02

    Historical records from the Department of Energy Hanford Nuclear Reservation (in eastern WA) indicate that ruptures in buried waste transfer pipelines were common between the 1940s and 1980s, which resulted in unplanned releases (UPRs) of tank: waste at numerous locations. A number of methods are commercially available for the detection of active or recent leaks, however, there are no methods available for the detection of leaks that occurred many years ago. Over the decades, leaks from the Hanford pipelines were detected by visual observation of fluid on the surface, mass balance calculations (where flow volumes were monitored), and incidental encounters with waste during excavation or drilling. Since these detection methods for historic leaks are so limited in resolution and effectiveness, it is likely that a significant number of pipeline leaks have not been detected. Therefore, a technology was needed to detect the specific location of unknown pipeline leaks so that characterization technologies can be used to identify any risks to groundwater caused by waste released into the vadose zone. A proof-of-concept electromagnetic geophysical survey was conducted at an UPR in order to image a historical leak from a waste transfer pipeline. The survey was designed to test an innovative electromagnetic geophysical technique that could be used to rapidly map the extent of historical leaks from pipelines within the Hanford Site complex. This proof-of-concept test included comprehensive testing and analysis of the transient electromagnetic method (TEM) and made use of supporting and confirmatory geophysical methods including ground penetrating radar, magnetics, and electrical resistivity characterization (ERC). The results for this initial proof-of-concept test were successful and greatly exceeded the expectations of the project team by providing excellent discrimination of soils contaminated with leaked waste despite the interference from an electrically conductive pipe.

  8. Instrument, in particular leak indicator, for the detection of a gas in a gas mixture

    Energy Technology Data Exchange (ETDEWEB)

    Patzelt, R.

    1975-01-30

    Leak indicator to determine the presence of an electronegative gas such as sulphur hexafluoride (SF/sub 6/) in a mixture with another gas, especially air, with a space containing the mixture and a high-frequency discharge column without electrodes as well as a voltmeter at this discharge column.

  9. 75 FR 4134 - Pipeline Safety: Leak Detection on Hazardous Liquid Pipelines

    Science.gov (United States)

    2010-01-26

    ... safety study on pipeline Supervisory Control and Data Acquisition (SCADA) systems (NTSB/SS-05/02). The... indications of a leak on the SCADA interface was the impetus for this study. The NTSB examined 13 hazardous... large pipeline breaks. The line balance processes incorporating SCADA or other technology are geared to...

  10. Leak detection technologies for oil and gas pipelines; Tecnologias para deteccao e localizacao de vazamento em dutos de oleo e ou gas

    Energy Technology Data Exchange (ETDEWEB)

    Alonso, Julio R. [MTT Aselco Automacao Ltda., Sao Paulo, SP (Brazil)

    2005-07-01

    Two concepts are available for leak detection in oil and/or gas pipelines: On-line leak detection system and off-line leak detection technique. The off-line leak detection technique is, usually, portable and does net configure a 'system'. This technique includes hydro-test, acoustic emission of high frequency, tracer of chemical substances, ultrasonic flow meter (UT), thermographic infra-red mapping, electromagnetic offset registration, etc. Since most of those methods requests stop of the system or depend on direct and detailed inspection of the whole monitored piping they are limited to the off-line inspection. In the current days there are only two technologies applied to detect and locate leaks on-line: The acoustic Leak Detection System and the modeling of computerized simulation also called as RTM (Real Time Modeling), RTTM or Mass Balance. There are still other techniques in the market, as acoustic emission, pressure analysis (PPA) beyond other rough techniques, without good results. Even some of these techniques are working without success, they are still used to accomplish with government standards. (author)

  11. Robust sensor placement for leak location: analysis and design

    OpenAIRE

    Blesa, Joaquim; Nejjari, Fatiha; Sarrate, Ramon

    2015-01-01

    In this paper, a nominal sensor placement methodology for leak location in water distribution networks is presented. To reduce the size and the complexity of the optimization problem a clustering technique is combined with the nominal sensor placement methodology. Some of the pressure sensor placement methods for leak detection and location in water distribution networks are based on the pressure sensitivity matrix analysis. This matrix depends on the network demands, which are nondeterminist...

  12. How Useful is Glucose Detection in Diagnosing Cerebrospinal Fluid Leak? The Rational Use of CT and Beta-2 Transferrin Assay in Detection of Cerebrospinal Fluid Fistula

    Directory of Open Access Journals (Sweden)

    Danny T.M. Chan

    2004-01-01

    Conclusions: Glucose detection using Glucostix test strips is not recommended as a confirmatory test due to its lack of specificity and sensitivity. In the presence of a skull base fracture on CT and a clinical CSF leak, there is no need for a further confirmatory test. In cases where a confirmatory test is needed, the beta-2 transferrin assay is the test of choice because of its high sensitivity and specificity.

  13. Results of Tank-Leak Detection Demonstration Using Geophysical Techniques at the Hanford Mock Tank Site-Fiscal Year 2001

    Energy Technology Data Exchange (ETDEWEB)

    Barnett, D BRENT.; Gee, Glendon W.; Sweeney, Mark D.

    2002-03-01

    During July and August of 2001, Pacific Northwest National Laboratory (PNNL), hosted researchers from Lawrence Livermore and Lawrence Berkeley National laboratories, and a private contractor, HydroGEOPHYSICS, Inc., for deployment of the following five geophysical leak-detection technologies at the Hanford Site Mock Tank in a Tank Leak Detection Demonstration (TLDD): (1) Electrical Resistivity Tomography (ERT); (2) Cross-Borehole Electromagnetic Induction (CEMI); (3) High-Resolution Resistivity (HRR); (4) Cross-Borehole Radar (XBR); and (5) Cross-Borehole Seismic Tomography (XBS). Under a ''Tri-party Agreement'' with Federal and state regulators, the U.S. Department of Energy will remove wastes from single-shell tanks (SSTs) and other miscellaneous underground tanks for storage in the double-shell tank system. Waste retrieval methods are being considered that use very little, if any, liquid to dislodge, mobilize, and remove the wastes. As additional assurance of protection of the vadose zone beneath the SSTs, tank wastes and tank conditions may be aggressively monitored during retrieval operations by methods that are deployed outside the SSTs in the vadose zone.

  14. Elevation profile influence at key contractual performance parameters for LDS (Leak Detection Systems) based on compensated volume balance

    Energy Technology Data Exchange (ETDEWEB)

    Liebenberg, Lieb [TRANSNET Pipeline, Durban (South Africa); Bueno, David; Passos, Rafaela [KANOPUS Consulting, Rio de Janeiro, RJ (Brazil)

    2009-07-01

    This paper describes and discusses procedures and correlations to estimate performance parameters for Leak Detection Systems based on Compensation Volume Balance, at the portions not usually covered by international standards (like, API RP 1130). These parameters include: minimum acceptable leakage to be detected, under steady state conditions, based on flow measurement uncertainty, observed for both pipeline head and tail; an actual flow rate uncertainty against the one informed by the flow meter manufacturer documentation; the reference flow rate for steady state conditions; and the sensitivity one may expect for the system against a given probability of false alarms (i.e., the ways to correlate reliability, the main performance parameter as per API RP 1130 and sensitivity, the second one). A question usually not considered is: how the elevation profile may affect some of these parameters. That is the second main objective addressed herein, with actual examples employed in a South African multi product pipeline. (author)

  15. Remote leak localization approach for fusion machines

    Energy Technology Data Exchange (ETDEWEB)

    Durocher, Au., E-mail: aurelien.durocher@cea.fr [CEA-IRFM, F-13108 Saint Paul-Lez-Durance (France); Bruno, V.; Chantant, M.; Gargiulo, L. [CEA-IRFM, F-13108 Saint Paul-Lez-Durance (France); Gherman, T. [Floralis UJF Filiale, F-38610 Gières (France); Hatchressian, J.-C.; Houry, M.; Le, R.; Mouyon, D. [CEA-IRFM, F-13108 Saint Paul-Lez-Durance (France)

    2013-10-15

    120 °C), “ppm” traces of helium or water have been measured. To improve these first promising results, a new test-bed called ROVE (remote operation vacuum equipment) has been set up in 2012 to qualify leak sensors and remote operation. A list of concepts has been set out from contacts with manufacturers and laboratories. For sniffing solutions it includes laser absorption measurement, mass spectrometer analyses and vibrating quartz. For embeddable concepts thermal conductivity and capacitive sensors are considered. Choice of concepts to detect water or helium traces is based on major criteria, such as weight, high sensibility and fast response time and recovery time. They also have to be operational under primary vacuum conditions or atmospheric pressure and from ambient temperature to 60 °C.

  16. Methane, Ethane, and Propane Sensor for Real-time Leak Detection and Diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Roscioli, Joseph R. [Aerodyne Research, Inc., Billerica, MA (United States); Herndon, Scott [Aerodyne Research, Inc., Billerica, MA (United States); Nelson, David D. [Aerodyne Research, Inc., Billerica, MA (United States); Yacovitch, Tara [Aerodyne Research, Inc., Billerica, MA (United States)

    2017-03-24

    The Phase I effort demonstrated the technical viability of a fast, sensitive, mobile hydrocarbon monitor. The instrument will enable the oil and gas industry, researchers, and regulators to rapidly identify and chemically profile leaks from facilities. This capability will allow operators to quickly narrow down and mitigate probable leaking equipment, minimizing product loss and penalties due to regulatory non-compliance. During the initial development phase, we demonstrated operation of a prototype monitor that is capable of measuring methane, ethane, and propane at sub-part-per-billion sensitivities in 1 second, using direct absorption infrared spectroscopy. To our knowledge, this is the first instrument capable of fast propane measurements at atmospheric concentrations. In addition, the electrical requirements of the monitor have been reduced from the 1,200 W typical of a spectrometer, to <500 W, making it capable of being powered by a passenger vehicle, and easily deployed by the industry. The prototype monitor leverages recent advances in laser technology, using high-efficiency interband cascade lasers to access the 3 μm region of the mid-infrared, where the methane, ethane, and propane absorptions are strongest. Combined with established spectrometer technology, we have achieved precisions below 200 ppt for each compound. This allows the monitor to measure fast plumes from oil and gas facilities, as well as ambient background concentrations (typical ambient levels are 2 ppm, 1.5 ppb, and 0.7 ppb for methane, ethane and propane, respectively). Increases in instrument operating pressure were studied in order to allow for a smaller 125 W pump to be used, and passive cooling was explored to reduce the cooling load by almost 90% relative to active (refrigerated) cooling. In addition, the simulated infrared absorption profiles of ethane and propane were modified to minimize crosstalk between species, achieving <1% crosstalk between ethane and propane. Finally, a

  17. Detection of leaks for radioactive tracer in marine duct for transport of liquefied petroleum gas; Deteccion de fugas por radiotrazado en ducto marino para transporte de gas LP

    Energy Technology Data Exchange (ETDEWEB)

    Robles P, E. F.; Benitez S, J. A.; Torre O, J. de la; Cruz S, E. de la; Molina, G.; Hernandez C, J. E.; Flores M, J. [ININ, 52750 La Marquesa, Estado de Mexico (Mexico)]. e mail: efrp@nuclear.inin.mx

    2008-07-01

    In this work the aplication in the oil industry of the technique of radioactive tracer appears for the detection of internal leaks in a submarine duct that gives service as it lines of receipt of liquefied petroleum gas (Gas LP) located in the Mexican coast of the Pacific Ocean. This system of marine pipe is a consistent arrangement of a duct interior of 0.254 m (10 inches) of nominal diameter (N.D.) of steel to the carbon for cryogenic service ASTM A 333, Grade 6, schedule 30, isolated thermally with foam of polyurethane and shielding in a steel tube to the carbon ASTM A 53 Grade A, of 0.508 m (20 inches) N. D., schedule 20, which is recovered by a ballast encircling of concrete of 0.0508 m (2 inches) of thickness, reinforced with mesh metallic, and that 1315 m runs on the marine stratum to a maximum depth of 12.5 m. For the detection of leaks by radiotracer it was used as tracer the radioactive isotope La-140 produced in the TRIGA Mark III Experimental Reactor of the National Institute of Nuclear Research, starting from stable lanthanum nitrate (La(NO{sub 3}){sub 3} 6H{sub 2}O), with an activity of 100 mCi, the one which after having been made logistics tasks, given very particular sea maneuvers and due to the conditions of the work place, in the interior tube was injected in two subsequent stages to cover both duct senses; from earth and from the marine end respectively, there being used fresh water like transport way and submergible sodium iodide detectors (NaI) for the rake of the La-140. At the end of the journeys of pursuit of the radiotracer, it was determine the presence of three leaks points located in the break area of the marine surf to 360 m, 450 m and 495 m of distance of a reference point located in the beach section named Trap of Devils. (Author)

  18. High-voltage leak detection of a parenteral proteinaceous solution product packaged in form-fill-seal plastic laminate bags. Part 1. Method development and validation.

    Science.gov (United States)

    Damgaard, Rasmus; Rasmussen, Mats; Buus, Peter; Mulhall, Brian; Guazzo, Dana Morton

    2013-01-01

    In Part 1 of this three-part research series, a leak test performed using high-voltage leak detection (HVLD) technology, also referred to as an electrical conductivity and capacitance leak test, was developed and validated for container-closure integrity verification of a small-volume laminate plastic bag containing an aqueous solution for injection. The sterile parenteral product is the rapid-acting insulin analogue, insulin aspart (NovoRapid®/NovoLog®, by Novo Nordisk A/S, Bagsværd, Denmark). The aseptically filled and sealed package is designed to preserve product sterility through expiry. Method development and validation work incorporated positive control packages with a single hole laser-drilled through the laminate film of each bag. A unique HVLD method characterized by specific high-voltage and potentiometer set points was established for testing bags positioned in each of three possible orientations as they are conveyed through the instrument's test zone in each of two possible directions-resulting in a total of six different test method options. Validation study results successfully demonstrated the ability of all six methods to accurately and reliably detect those packages with laser-drilled holes from 2.5-11.2 μm in nominal diameter. Part 2 of this series will further explore HVLD test results as a function of package seal and product storage variables. The final Part 3 will report the impact of HVLD exposure on product physico-chemical stability. In this Part 1 of a three-part research series, a leak test method based on electrical conductivity and capacitance, called high voltage leak detection (HVLD), was used to find leaks in small plastic bags filled with an insulin pharmaceutical solution for human injection by Novo Nordisk A/S (Bagsværd, Denmark). To perform the test, the package is electrically grounded while being conveyed past an electrode linked to a high-voltage, low-amperage transformer. The instrument measures the current that passes

  19. Accuracy improvement in leak detection of charcoal adsorbers by halide pulse integration method

    Energy Technology Data Exchange (ETDEWEB)

    Kovach, B.J.; Banks, E.M. [NUCON International, Inc., Columbus, OH (United States)

    1997-08-01

    Due to the phaseout of the supply of R-11, which is used as a charcoal adsorber leak-testing agent, several new substitutes have been suggested and tested. Pulse testing using agents with higher boiling points produced longer response times (due to prolonged evaporation and dispersion times). This longer evaporation time alters the pulse shape and lowers the peak concentration. Since the dispersion and evaporation time under different ambient condition are unpredictable, the peak concentration becomes unpredictable as well. One way to eliminate this unpredictability is to determine the area under the curve (of concentration versus time) after test-agent injection rather than the peak concentration (height). This value should be independent of the injection time and evaporation rate as long as the volume of the test agent injected remains constant. Thus, tests were performed with a constant volume injection of test agent but with different injection times and evaporation rates. The area under the curve of concentration versus time was then compared with the peak concentration for each injection. 4 refs., 1 fig.

  20. 3-D glass fabric-AHC epoxy laminates: Reinforced double linings with leak detection for above and below ground storage tanks

    Energy Technology Data Exchange (ETDEWEB)

    O' Donoghue, M.; Garrett, R.; Datta, V.J. [ICI Devoe Coatings Company (United States); Swinkels, K. [Parabeam (Netherlands); Crevolin, P. [CSI Coating Systems Inc (Canada)

    1999-07-01

    A unique three dimensional E-Glass Fabric/Advanced Hybrid Cycloaliphatic solventless epoxy laminate (3-D Glass Fabric/AHC System), which represents an innovative and cost-effective approach to safeguarding against accidental leakage of cargo from above ground (AST) and underground ( UST) storage containers, is described. This composite laminate provides an internal double layer and a secondary containment leak detection system and forms a chemically and thermally resistant integrated sandwich structure that prevents the side leaking of petroleum products into the environment, even when side corrosion produces a hole through the bottom of an AST, or the shell of a UST. The paper provides details of the components of the 3-D Glass Fabric/AHC System, relevant installation, testing, repair and leak detection procedures, and evaluation from two installations. 13 refs., 6 tabs., 6 figs.

  1. Three-phase flow (water, oil and gas in a vertical circular cylindrical duct with leaks: A theoretical study

    Directory of Open Access Journals (Sweden)

    W Santos

    2016-10-01

    Full Text Available This article describes the fluid dynamic behavior of a three-phase flow (water-oil-natural gas in a vertical pipe with or without leakage. The studied pipe has 8 meters in length, circular cross-section with 25 cm in diameter and a leak, which hole has a circular shape with 10mm diameter located in the center of pipe. The conservation equations of mass, momentum and energy for each phase (continuous phase - oil, dispersed phases - gas and water were numerically solved using ANSYS CFX software, in which the Eulerian-Eulerian model and the RNG - turbulence model were applied. Results of the pressure, velocity, temperature and volume fraction distributions of the involved phases are present and analyzed.

  2. Rust Contamination from Water Leaks in the Cosmic Dust Lab and Lunar and Meteorite Thin Sections Labs at Johnson Space Center

    Science.gov (United States)

    Kent, J. J.; Berger, E. L.; Fries, M. D.; Bastien, R.; McCubbin, F. M.; Pace, L.; Righter, K.; Sutter, B.; Zeigler, R. A.; Zolensky, M.

    2017-01-01

    On the early morning of September 15th, 2016, on the first floor of Building 31 at NASA-Johnson Space Center, the hose from a water chiller ruptured and began spraying water onto the floor. The water had been circulating though old metal pipes, and the leaked water contained rust-colored particulates. The water flooded much of the western wing of the building's ground floor before the leak was stopped, and it left behind a residue of rust across the floor, most notably in the Apollo and Meteorite Thin Section Labs and Sample Preparation Lab. No samples were damaged in the event, and the affected facilities are in the process of remediation. At the beginning of 2016, a separate leak occurred in the Cosmic Dust Lab, located in the same building. In that lab, a water leak occurred at the bottom of the sink used to clean the lab's tools and containers with ultra-pure water. Over years of use, the ultra-pure water eroded the metal sink piping and leaked water onto the inside of the lab's flow bench. This water also left behind a film of rusty material. The material was cleaned up and the metal piping was replaced with PVC pipe and sealed with Teflon plumber's tape. Samples of the rust detritus were collected from both incidents. These samples were imaged and analyzed to determine their chemical and mineralogical compositions. The purpose of these analyses is to document the nature of the detritus for future reference in the unlikely event that these materials occur as contaminants in the Cosmic Dust samples or Apollo or Meteorite thin sections.

  3. Fundamental study on leak detection of underground gas pipeline using passive acoustic method; Judogata onkyo keisoku ni yoru maisetsu gas dokan hason kasho no kenshutsu ni kansuru kenkyu

    Energy Technology Data Exchange (ETDEWEB)

    Jinguji, M.; Imaizumi, H.; Kunimatsu, S.; Isei, T. [National Institute for Resources and Environment, Tsukuba (Japan)

    1997-05-27

    With an objective to detect gas leaking from an underground gas pipeline, discussions have been given on a method which utilizes acoustic characteristics of leakage. On leaking sound generated from damaged portions, the form of damaging was hypothesized as pinholes, and spectra of leaking sounds from holes with different diameters were measured. The dominant frequency decreases as the hole diameter increases, while it is in a region of relatively high frequency of 1 kHz or higher. However, detection from the ground surface was impossible when cover soil has thickness from 0.5 to 1.5 m. In an experiment to measure leaking sound inside the pipe, pressure in the pipe was adjusted to 0.02 atm which is a standard pressure for a low-pressure pipe, and the sound was measured when the hole diameters were varied. In any of the results obtained by varying the hole diameter, spectra having the dominant frequency in the region of 1 kHz or higher were measured. In addition, it was found that sound pressure difference of as much as 50 dB at maximum is generated as compared with a case of no sound leakage. The above results verified that monitoring the high frequency of 1 kHz or higher is effective in detecting leakage from small damages. 2 refs., 4 figs.

  4. Detection of CO2 leaks from carbon capture and storage sites to the atmosphere with combined CO2 and O2 measurements

    Science.gov (United States)

    van Leeuwen, Charlotte; Meijer, Harro A. J.

    2015-04-01

    One of the main issues in carbon capture and storage (CCS) is the possibility of leakage of CO2 from the storage reservoir to the atmosphere, both from a public health and a climate change combat perspective. Detecting these leaks in the atmosphere is difficult due to the rapid mixing of the emitted CO2 with the surrounding air masses and the high natural variability of the atmospheric CO2 concentration. Instead of measuring only the CO2 concentration of the atmosphere, its isotopes or chemical tracers that are released together with the CO2, our method uses O2 measurements in addition to CO2 measurements to detect a leak from a CCS site. CO2 and O2 are coupled in most processes on earth. In photosynthesis, plants take up CO2 and release O2 at the same time. In respiration and fossil fuel burning, O2 is consumed while CO2 is released. In case of a leak from a CCS site, however, there is no relationship between CO2 and O2. A CO2 leak can therefore be distinguished from other sources of CO2 by looking at the atmospheric CO2-O2 ratio. A natural increase of the CO2 concentration is accompanied by a drop in the O2 concentration, while an increase in the CO2 concentration caused by a leak from a CCS site does not have any effect on the O2 concentration. To demonstrate this leak detection strategy we designed and built a transportable CO2 and O2 measurement system, that is capable of measuring the relatively minute (ppm's variations on a 21% concentration) changes in the O2 concentration. The system comprises of three cases that contain the instrumentation and gas handling equipment, the gas cylinders used as reference and calibration gases and a drying system, respectively. Air is pumped to the system from an air inlet that is placed in a small tower in the field. At the conference, we will demonstrate the success of leak detection with our system by showing measurements of several CO2 release experiments, where CO2 was released at a small distance from the air inlet of

  5. Multi-Spectral imaging of vegetation for detecting CO2 leaking from underground

    Energy Technology Data Exchange (ETDEWEB)

    Rouse, J.H.; Shaw, J.A.; Lawrence, R.L.; Lewicki, J.L.; Dobeck, L.M.; Repasky, K.S.; Spangler, L.H.

    2010-06-01

    Practical geologic CO{sub 2} sequestration will require long-term monitoring for detection of possible leakage back into the atmosphere. One potential monitoring method is multi-spectral imaging of vegetation reflectance to detect leakage through CO{sub 2}-induced plant stress. A multi-spectral imaging system was used to simultaneously record green, red, and near-infrared (NIR) images with a real-time reflectance calibration from a 3-m tall platform, viewing vegetation near shallow subsurface CO{sub 2} releases during summers 2007 and 2008 at the Zero Emissions Research and Technology field site in Bozeman, Montana. Regression analysis of the band reflectances and the Normalized Difference Vegetation Index with time shows significant correlation with distance from the CO{sub 2} well, indicating the viability of this method to monitor for CO{sub 2} leakage. The 2007 data show rapid plant vigor degradation at high CO{sub 2} levels next to the well and slight nourishment at lower, but above-background CO{sub 2} concentrations. Results from the second year also show that the stress response of vegetation is strongly linked to the CO{sub 2} sink-source relationship and vegetation density. The data also show short-term effects of rain and hail. The real-time calibrated imaging system successfully obtained data in an autonomous mode during all sky and daytime illumination conditions.

  6. Early tube leak detection system for steam boiler at KEV power plant

    Directory of Open Access Journals (Sweden)

    Ismail Firas B.

    2016-01-01

    Full Text Available Tube leakage in boilers has been a major contribution to trips which eventually leads to power plant shut downs. Training of network and developing artificial neural network (ANN models are essential in fault detection in critically large systems. This research focusses on the ANN modelling through training and validation of real data acquired from a sub-critical boiler unit. The artificial neural network (ANN was used to develop a compatible model and to evaluate the working properties and behaviour of boiler. The training and validation of real data has been applied using the feed-forward with back-propagation (BP. The right combination of number of neurons, number of hidden layers, training algorithms and training functions was run to achieve the best ANN model with lowest error. The ANN was trained and validated using real site data acquired from a coal fired power plant in Malaysia. The results showed that the Neural Network (NN with one hidden layers performed better than two hidden layer using feed-forward back-propagation network. The outcome from this study give us the best ANN model which eventually allows for early detection of boiler tube leakages, and forecast of a trip before the real shutdown. This will eventually reduce shutdowns in power plants.

  7. Research and development for the high-temperature helium-leak detection system (Joint research). Part 2. Development of temperature sensors using optical fibre for the HTTR

    Energy Technology Data Exchange (ETDEWEB)

    Sakaba, Nariaki; Nakazawa, Toshio; Kawasaki, Kozo [Japan Atomic Energy Research Inst., Oarai, Ibaraki (Japan). Oarai Research Establishment; Urakami, Masao; Saisyu, Sadanori [Japan Atomic Power Co., Tokyo (Japan)

    2003-03-01

    In the second stage of the research and development for a high-temperature helium-leak detection system, the temperature sensor using optical fibres was studied. The sensor detects the helium leakage by the temperature increase surrounded optical fibre with or without heat insulator. Moreover, the applicability of high temperature equipments as the HTTR system was studied. With the sensor we detected 5.0-20.0 cm{sup 3}/s helium leakages within 60 minutes. Also it was possible to detect earlier when the leakage level is at 20.0 cm {sup 3}/s. (author)

  8. Helium Leak Detection of Vessels in Fuel Transfer Cell (FTC) of Prototype Fast Breeder Reactor (PFBR)

    Science.gov (United States)

    Dutta, N. G.

    2012-11-01

    Bharatiya Nabhikiya Vidyut Nigam (BHAVINI) is engaged in construction of 500MW Prototype Fast Breeder Reactor (PFBR) at Kalpak am, Chennai. In this very important and prestigious national programme Special Product Division (SPD) of M/s Kay Bouvet Engg.pvt. ltd. (M/s KBEPL) Satara is contributing in a major way by supplying many important sub-assemblies like- Under Water trolley (UWT), Airlocks (PAL, EAL) Container and Storage Rack (CSR) Vessels in Fuel Transfer Cell (FTC) etc for PFBR. SPD of KBEPL caters to the requirements of Government departments like - Department of Atomic Energy (DAE), BARC, Defense, and Government undertakings like NPCIL, BHAVINI, BHEL etc. and other precision Heavy Engg. Industries. SPD is equipped with large size Horizontal Boring Machines, Vertical Boring Machines, Planno milling, Vertical Turret Lathe (VTL) & Radial drilling Machine, different types of welding machines etc. PFBR is 500 MWE sodium cooled pool type reactor in which energy is produced by fissions of mixed oxides of Uranium and Plutonium pellets by fast neutrons and it also breeds uranium by conversion of thorium, put along with fuel rod in the reactor. In the long run, the breeder reactor produces more fuel then it consumes. India has taken the lead to go ahead with Fast Breeder Reactor Programme to produce electricity primarily because India has large reserve of Thorium. To use Thorium as further fuel in future, thorium has to be converted in Uranium by PFBR Technology.

  9. Antipodal Vivaldi Antenna to Detect UHF Signals That Leaked Out of the Joint of a Transformer

    Directory of Open Access Journals (Sweden)

    Jian Zhang

    2017-01-01

    Full Text Available In recent years, extensive research has been conducted on the ultrahigh-frequency (UHF method. Considering that acquiring a partial discharge UHF signal is the first step in a series of tasks, such as fault diagnosis and defect location, the UHF sensor plays an important role in the UHF method. An antipodal Vivaldi antenna installed at a transformer’s joint is designed in this study according to the structural features of 750 kV transformers in China. Several effective structures, such as linear gradient microstrip and slot edge, are employed to improve the return loss and radiation characteristics. A metal box is designed after analyzing the influence of the metal around the antenna. The metal box can effectively shield against electromagnetic interference and does not deteriorate the performance of the antenna significantly. Experimental data show that this antenna is much more sensitive than the rectangular plane spiral antenna. The proposed antipodal Vivaldi antenna is suitable for detecting partial discharge in large transformers.

  10. Integration of modelbased leak recognition- and detection systems. Experiences from the international project work; Integration modellbasierter Leckerkennungs- und Ortungssysteme. Erfahrungen aus der internationalen Projektarbeit

    Energy Technology Data Exchange (ETDEWEB)

    Ippa, A.; Swidersky, H. [MAGNUM Automatisierungstechnik GmbH, Darmstadt (Germany)

    2004-08-01

    The problems relating to the installation of a leak recognition and detection system in a long-distance pipeline are discussed. Apart from the economic boundary conditions, there are technical problems as well. Examples from successfully completed projects are presented, and criteria are discussed which should be taken into account when equipping or retrofitting a pipeline with leak detection systems. (orig.) [German] Fuer den Betreiber, Anlagenplaner und Systemlieferanten bringt die Ausruestung einer Rohrfernleitung mit einem Leckerkennungs- und Leckortungssystem verschiedene Anforderungen mit sich. Solche automatischen Ueberwachungssysteme verfuegen ueber Algorithmen zur Detektion (Leckerkennung), Diagnose (Leckortung) und Reaktion (z.B. Foerderstopp, Drucksenkung). Neben wirtschaftlichen Aspekten steht die technische Realisierbarkeit unter Einhaltung der geforderten Genauigkeiten und den termingerechten spezifischen Anpassungen im Vordergrund. Anhand durchgefuehrter Projekte werden eine Reihe von Kriterien diskutiert, die beim Aus- oder Nachruesten von Pipelines mit einem Leckerkennungssystem beruecksichtigt werden muessen und dem Anlagenbetreiber konkrete Hilfestellung bei der Konzeption geben. (orig.)

  11. Test Plan for the Demonstration of Geophysical Techniques for Single-Shell Tank Leak Detection at the Hanford Mock Tank Site: Fiscal Year 2001

    Energy Technology Data Exchange (ETDEWEB)

    Barnett, D. Brent; Gee, Glendon W.; Sweeney, Mark D.

    2001-07-31

    As part of the Leak Detection, Monitoring and Mitigation (LDMM) program conducted by CH2M HILL 105-A during FY 2001. These tests are being conducted to assess the applicability of these methods (Electrical Resistance Tomography [ERT], High Resolution Resistivity [HRR], Cross-Borehole Seismography [XBS], Cross-Borehole Radar [XBR], and Cross-Borehole Electromagnetic Induction [CEMI]) to the detection and measurement of Single Shell Tank (SST) leaks into the vadose zone during planned sluicing operations. The testing in FY 2001 will result in the selection of up to two methods for further testing in FY 2002. In parallel with the geophysical tests, a Partitioning Interwell Tracer Test (PITT) study will be conducted simultaneously at the Mock Tank to assess the effectiveness of this technology in detecting and quantifying tank leaks in the vadose zone. Preparatory and background work using Cone Penetrometer methods (CPT) will be conducted at the Mock Tank site and an adjacent test area to derive soil properties for groundtruthing purposes for all methods.

  12. Modeling and detection of oil in sea water

    DEFF Research Database (Denmark)

    Xenaki, Angeliki; Gerstoft, Peter; Mosegaard, Klaus

    2013-01-01

    The challenge of a deep-water oil leak is that a significant quantity of oil remains in the water column and possibly changes properties. There is a need to quantify the oil settled within the water column and determine its physical properties to assist in the oil recovery. There are currently...... no methods to map acoustically submerged oil in the sea. In this paper, high-frequency acoustic methods are proposed to localize the oil polluted area and characterize the parameters of its spatial covariance, i.e., variance and correlation. A model is implemented to study the underlying mechanisms...... for inference of spatial covariance parameters is proposed to describe the scattering field in terms of its second-order statistics from the backscattered returns. The results indicate that high-frequency acoustic methods not only are suitable for large-scale detection of oil contamination in the water column...

  13. Leveraging Social Norms to Improve Leak Resolution Outcomes Across Meter Classes:

    Science.gov (United States)

    Holleran, W.

    2016-12-01

    Over the past decade, utilities, governments, businesses, and nonprofits have come to realize that more than just financial considerations and information drive behavior. Social and psychological factors also play a significant role in shaping consumers' decisions and behaviors around resource use. Stakeholders have consequently turned their interest to behavioral science, a multidisciplinary field that draws from psychology, sociology, public health, and behavioral economics to explain the complex mechanisms that shape human behavior. When used strategically, behavioral science holds the potential to drive down resource use, drive up profits, and generate measurable gains in conservation and efficiency. WaterSmart will present on how the water sector can employ behavioral science to nudge residential rate-payers to use water more efficiently and help them save money. Utilities can use behavioral science to influence people's reaction to leaks. 5% of Single Family Residential (SFR) metered water use can be attributed to leaks. This value potentially skews even higher for MultiFamily (MF) and Commercial accounts given that it can get lost in the noise of daily consumption. Existing leak detection algorithms in the market are not sophisticated enough to detect leaks for a MF or Commercial property. Leveraging data from utilities on known leak events at MF and Commercial buildings allowed WaterSmart to train a machine learning model to identify key features in the load shape and accurately detect these types of water use events. The outcome of the model is a leak amount and confidence level for each irregular usage event. The model also incorporates record feedback from users on the type of leak event, and the accuracy of the alert. When WaterSmart leverages this data model with social norms messaging, we've been able to improve water demand management for MF and Commercial properties. Experiences from leak detection and resolution in the SFR space will also be

  14. Detection in superheated water chromatography

    Energy Technology Data Exchange (ETDEWEB)

    Chienthavorn, O

    1999-11-01

    Superheated water has been used successfully as an eluent in liquid chromatography and has been coupled to various modes of detection, ultraviolet (UV), fluorescence, and nuclear magnetic resonance spectroscopy (NMR) and mass spectrometry (MS). A number of compounds were examined on poly(styrene-divinylbenzene) (PS-DVB), polybutadiene (PBD), and octadecylsilyl bonded silica (ODS) column with isothermal and temperature programmes. The PS-DVB column was mostly used throughout the project as it was the most stable. Not only pure water could serve as superheated water mobile phase; inorganic buffered water and ion-pairing reagent with a concentration of 1-3 mM of the buffer and reagent were also exploited. It was shown that the pH could be controlled during the separation without salt precipitation and the separations followed a conventional reversed-phase HPLC method. Results from fluorescence detection showed good separation of a series of vitamins, such as pyridoxine, riboflavin, thiamine, and some analgesics. The relationship of riboflavin using the detection was linear and the detection limit was seven times higher than that of a conventional method. Simultaneous separation and identification using superheated water chromatography-NMR was demonstrated. With using a stop flow method, NMR spectra of model drugs, namely barbiturates, paracetamol, caffeine and phenacetin were obtained and the results agreed with reference spectra, confirming a perfect separation. A demonstration to obtain COSY spectrum of salicylamide was also performed. The method was expanded to the coupling of superheated water LC to NMR-MS. Results from the hyphenated detection method showed that deuteration and degradation happened in the superheated water conditions. The methyl group hydrogens of pyrimidine ring of sulfonamide and thiamine were exchanged with deuterium. Thiamine was decomposed to 4-methyl-5-thiazoleethanol and both were deuterated under the conditions. (author)

  15. The calculation of the highest leak level of water pipe lines region at PDAM Tirta Kahuripan using fuzzy C-means and ArcGIS method analysis

    Science.gov (United States)

    Parwatiningtyas, D.; Ambarsari, E. W.; Mariko, S.

    2017-07-01

    Water is a basic necessity for human's life. Water, which is distributed to the public, should in decent condition, healthy, and protected from metal pollutants. In Indonesia, it is handled by a government institution, commonly is PDAM (Indonesian regional water utility company). A PDAM Tirta Kahuripan handles water distribution in Bogor area and part of Depok cities. Based on data, PDAM Tirta Kahuripan had approximately more than 46 % water loss, due to geological factor, human activity, etc. Therefore in this paper, we try to make a decision system of water loss at PDAM pipelines, using cluster Fuzzy C - Means method analysis. Then, mapped into ArcGIS software. Based on this method, we can be determine the region which shows the most water loss and also identify the highest leaks level from water pipelines at PDAM Tirta Kahuripan.

  16. Leak before break application in French PWR plants under operation

    Energy Technology Data Exchange (ETDEWEB)

    Faidy, C. [EDF SEPTEN, Villeurbanne (France)

    1997-04-01

    Practical applications of the leak-before break concept are presently limited in French Pressurized Water Reactors (PWR) compared to Fast Breeder Reactors. Neithertheless, different fracture mechanic demonstrations have been done on different primary, auxiliary and secondary PWR piping systems based on similar requirements that the American NUREG 1061 specifications. The consequences of the success in different demonstrations are still in discussion to be included in the global safety assessment of the plants, such as the consequences on in-service inspections, leak detection systems, support optimization,.... A large research and development program, realized in different co-operative agreements, completes the general approach.

  17. Leak test fitting

    Science.gov (United States)

    Pickett, P.T.

    A hollow fitting for use in gas spectrometry leak testing of conduit joints is divided into two generally symmetrical halves along the axis of the conduit. A clip may quickly and easily fasten and unfasten the halves around the conduit joint under test. Each end of the fitting is sealable with a yieldable material, such as a piece of foam rubber. An orifice is provided in a wall of the fitting for the insertion or detection of helium during testing. One half of the fitting also may be employed to test joints mounted against a surface.

  18. Active Stand-off Detection of Gas Leaks Using a Short Range Hard-target Backscatter Differential Optical Absorption System Based on a Quantum Cascade Laser Transmitter

    Science.gov (United States)

    Diaz, Adrian; Thomas, Benjamin; Castillo, Paulo; Gross, Barry; Moshary, Fred

    2016-06-01

    Fugitive gas emissions from agricultural or industrial plants and gas pipelines are an important environmental concern as they can contribute to the global increase of greenhouse gas concentration. Moreover, they are also a security and safety concern because of possible risk of fire/explosion or toxicity. This study presents gas concentration measurements using a quantum cascade laser open path system (QCLOPS). The system retrieves the pathaveraged concentration of N2O and CH4 by collecting the backscattered light from a scattering target. The gas concentration measurements have a high temporal resolution (68 ms) and are achieved at sufficient range (up to 40 m, ~ 130 feet) with a detection limit of 2.6 ppm CH4 and 0.4 ppm for N2O. Given these characteristics, this system is promising for mobile/multidirectional remote detection and evaluation of gas leaks. The instrument is monostatic with a tunable QCL emitting at ~ 7.7 μm wavelength range. The backscattered radiation is collected by a Newtonian telescope and focused on an infrared light detector. Puffs of N2O and CH4 are released along the optical path to simulate a gas leak. The measured absorption spectrum is obtained using the thermal intra-pulse frequency chirped DFB QCL and is analyzed to obtain path averaged gas concentrations.

  19. Active standoff detection of CH4 and N2O leaks using hard-target backscattered light using an open-path quantum cascade laser sensor

    Science.gov (United States)

    Diaz, Adrian; Thomas, Benjamin; Castillo, Paulo; Gross, Barry; Moshary, Fred

    2016-05-01

    Fugitive gas emissions from agricultural or industrial plants and gas pipelines are an important environmental concern as they contribute to the global increase of greenhouse gas concentrations. Moreover, they are also a security and safety concern because of possible risk of fire/explosion or toxicity. This study presents standoff detection of CH4 and N2O leaks using a quantum cascade laser open-path system that retrieves path-averaged concentrations by collecting the backscattered light from a remote hard target. It is a true standoff system and differs from other open-path systems that are deployed as point samplers or long-path transmission systems that use retroreflectors. The measured absorption spectra are obtained using a thermal intra-pulse frequency chirped DFB quantum cascade laser at ~7.7 µm wavelength range with ~200 ns pulse width. Making fast time resolved observations, the system simultaneously realizes high spectral resolution and range to the target, resulting in path-averaged concentration retrieval. The system performs measurements at high speed ~15 Hz and sufficient range (up to 45 m, ~148 feet) achieving an uncertainty of 3.1 % and normalized sensitivity of 3.3 ppm m Hz-1/2 for N2O and 9.3 % and normalized sensitivity of 30 ppm m Hz-1/2 for CH4 with a 0.31 mW average power QCL. Given these characteristics, this system is promising for mobile or multidirectional search and remote detection of gas leaks.

  20. Active Stand-off Detection of Gas Leaks Using a Short Range Hard-target Backscatter Differential Optical Absorption System Based on a Quantum Cascade Laser Transmitter

    Directory of Open Access Journals (Sweden)

    Diaz Adrian

    2016-01-01

    Full Text Available Fugitive gas emissions from agricultural or industrial plants and gas pipelines are an important environmental concern as they can contribute to the global increase of greenhouse gas concentration. Moreover, they are also a security and safety concern because of possible risk of fire/explosion or toxicity. This study presents gas concentration measurements using a quantum cascade laser open path system (QCLOPS. The system retrieves the pathaveraged concentration of N2O and CH4 by collecting the backscattered light from a scattering target. The gas concentration measurements have a high temporal resolution (68 ms and are achieved at sufficient range (up to 40 m, ~ 130 feet with a detection limit of 2.6 ppm CH4 and 0.4 ppm for N2O. Given these characteristics, this system is promising for mobile/multidirectional remote detection and evaluation of gas leaks. The instrument is monostatic with a tunable QCL emitting at ~ 7.7 μm wavelength range. The backscattered radiation is collected by a Newtonian telescope and focused on an infrared light detector. Puffs of N2O and CH4 are released along the optical path to simulate a gas leak. The measured absorption spectrum is obtained using the thermal intra-pulse frequency chirped DFB QCL and is analyzed to obtain path averaged gas concentrations.

  1. Leakage Detection and Estimation Algorithm for Loss Reduction in Water Piping Networks

    Directory of Open Access Journals (Sweden)

    Kazeem B. Adedeji

    2017-10-01

    Full Text Available Water loss through leaking pipes constitutes a major challenge to the operational service of water utilities. In recent years, increasing concern about the financial loss and environmental pollution caused by leaking pipes has been driving the development of efficient algorithms for detecting leakage in water piping networks. Water distribution networks (WDNs are disperse in nature with numerous number of nodes and branches. Consequently, identifying the segment(s of the network and the exact leaking pipelines connected to this segment(s where higher background leakage outflow occurs is a challenging task. Background leakage concerns the outflow from small cracks or deteriorated joints. In addition, because they are diffuse flow, they are not characterised by quick pressure drop and are not detectable by measuring instruments. Consequently, they go unreported for a long period of time posing a threat to water loss volume. Most of the existing research focuses on the detection and localisation of burst type leakages which are characterised by a sudden pressure drop. In this work, an algorithm for detecting and estimating background leakage in water distribution networks is presented. The algorithm integrates a leakage model into a classical WDN hydraulic model for solving the network leakage flows. The applicability of the developed algorithm is demonstrated on two different water networks. The results of the tested networks are discussed and the solutions obtained show the benefits of the proposed algorithm. A noteworthy evidence is that the algorithm permits the detection of critical segments or pipes of the network experiencing higher leakage outflow and indicates the probable pipes of the network where pressure control can be performed. However, the possible position of pressure control elements along such critical pipes will be addressed in future work.

  2. A method for compressor stations' leak detection and methane emission monitoring; Une methode pour la detection des fuites et la surveillance des emissions de methane dans les stations de compression

    Energy Technology Data Exchange (ETDEWEB)

    Suomilammi, A. [Gasum Oy (Finland)

    2000-07-01

    Reduction of methane emissions has been a topic of high interest in the gas industry. Several different methods for leak detection and emission measurement has been introduced in recent years with various methods. Gasum Oy, a Finnish gas transmission company, installed in 1997 to the compressor stations of the gas transmission network, a methane leak detection and emission measurement system, which utilizes the existing station instrumentation, control and reporting systems. The method in this system, to detect the leaks and measure the emissions, is based on the pressure levels in the station pipework sections and the station valve statuses. When the station or unit is stopped the station or unit valves are closed and the pipework remain pressurised. Pressure levels are recorded and at the next time when the station or unit is started, the pressure drop is calculated and the methane emission from that pipework section is calculated and reported. The reported data is available for all operators in the dispatching centre and compressor stations' maintenance staff The method is commonly known, but in Gasum's application, the whole system is automated for 3 different compressor stations having total of 9 compressor units. The experience until today shows a clear decrease of methane emissions from compressor stations due to better monitoring and as a consequence, due to the fast response to perform the corrective actions. (author)

  3. Reducing leaks in water distribution networks. Controlling pressure by means of automatic hydraulic valves; Reduccion de fugas en redes de distribucion de agua. Control de la presion mediante valvulas hidraulicas automaticas

    Energy Technology Data Exchange (ETDEWEB)

    Singla Font, S.

    2005-07-01

    Any water distribution network, bet it of drinking water or irrigation water, always loses an inevitable amount. One of the main ways to reduce leaks is to optimise the pressure in the network by means of hydraulic valves with different types of control devices. These can be either completely hydraulic or supplemented by electronic systems. (Author)

  4. Detecting pipe bursts by monitoring water demand

    NARCIS (Netherlands)

    Bakker, M.; Vreeburg, J.H.G.; Van der Roer, M.; Sperber, V.

    2012-01-01

    An algorithm which compares measured and predicted water demands to detect pipe bursts was developed and tested on three data sets of water demand and reported pipe bursts of three years. The algorithm proved to be able to detect bursts where the water loss exceeds 30% of the average water demand in

  5. Location estimation method of steam leak in pipeline using leakage area analysis

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Se Oh; Jeon, Hyeong Seop; Son, Ki Sung [Sae An Engineering Corp., Seoul (Korea, Republic of); Park, Jong Won [Dept. of Information Communications Engineering, Chungnam National University, Daejeon (Korea, Republic of)

    2016-10-15

    It is important to have a pipeline leak-detection system that determines the presence of a leak and quickly identifies its location. Current leak detection methods use a acoustic emission sensors, microphone arrays, and camera images. Recently, many researchers have been focusing on using cameras for detecting leaks. The advantage of this method is that it can survey a wide area and monitor a pipeline over a long distance. However, conventional methods using camera monitoring are unable to target an exact leak location. In this paper, we propose a method of detecting leak locations using leak-detection results combined with multi-frame analysis. The proposed method is verified by experiment.

  6. Daytime Water Detection Based on Sky Reflections

    Science.gov (United States)

    Rankin, Arturo; Matthies, Larry; Bellutta, Paolo

    2011-01-01

    A water body s surface can be modeled as a horizontal mirror. Water detection based on sky reflections and color variation are complementary. A reflection coefficient model suggests sky reflections dominate the color of water at ranges > 12 meters. Water detection based on sky reflections: (1) geometrically locates the pixel in the sky that is reflecting on a candidate water pixel on the ground (2) predicts if the ground pixel is water based on color similarity and local terrain features. Water detection has been integrated on XUVs.

  7. 75 FR 76742 - Detecting Oil Leaks From Vessels Into the Water

    Science.gov (United States)

    2010-12-09

    ... ``Document Type'' drop down menu select ``Notices'' and insert ``USCG-2010-1085'' in the ``Keyword'' box... copying and electronic filing. If you submit them by mail and would like to know that they reached the... electronic form of comments received into any of our dockets by the name of the individual submitting the...

  8. Adaptive Kalman Filter Based on Adjustable Sampling Interval in Burst Detection for Water Distribution System

    Directory of Open Access Journals (Sweden)

    Doo Yong Choi

    2016-04-01

    Full Text Available Rapid detection of bursts and leaks in water distribution systems (WDSs can reduce the social and economic costs incurred through direct loss of water into the ground, additional energy demand for water supply, and service interruptions. Many real-time burst detection models have been developed in accordance with the use of supervisory control and data acquisition (SCADA systems and the establishment of district meter areas (DMAs. Nonetheless, no consideration has been given to how frequently a flow meter measures and transmits data for predicting breaks and leaks in pipes. This paper analyzes the effect of sampling interval when an adaptive Kalman filter is used for detecting bursts in a WDS. A new sampling algorithm is presented that adjusts the sampling interval depending on the normalized residuals of flow after filtering. The proposed algorithm is applied to a virtual sinusoidal flow curve and real DMA flow data obtained from Jeongeup city in South Korea. The simulation results prove that the self-adjusting algorithm for determining the sampling interval is efficient and maintains reasonable accuracy in burst detection. The proposed sampling method has a significant potential for water utilities to build and operate real-time DMA monitoring systems combined with smart customer metering systems.

  9. Daytime Water Detection Based on Sky Reflections

    Science.gov (United States)

    Rankin, Arturo L.; Matthies, Larry H.; Bellutta, Paolo

    2011-01-01

    Robust water detection is a critical perception requirement for unmanned ground vehicle (UGV) autonomous navigation. This is particularly true in wide-open areas where water can collect in naturally occurring terrain depressions during periods of heavy precipitation and form large water bodies. One of the properties of water useful for detecting it is that its surface acts as a horizontal mirror at large incidence angles. Water bodies can be indirectly detected by detecting reflections of the sky below the horizon in color imagery. The Jet Propulsion Laboratory (JPL) has implemented a water detector based on sky reflections that geometrically locates the pixel in the sky that is reflecting on a candidate water pixel on the ground and predicts if the ground pixel is water based on color similarity and local terrain features. This software detects water bodies in wide-open areas on cross-country terrain at mid- to far-range using imagery acquired from a forward-looking stereo pair of color cameras mounted on a terrestrial UGV. In three test sequences approaching a pond under a clear, overcast, and cloudy sky, the true positive detection rate was 100% when the UGV was beyond 7 meters of the water's leading edge and the largest false positive detection rate was 0.58%. The sky reflection based water detector has been integrated on an experimental unmanned vehicle and field tested at Ft. Indiantown Gap, PA, USA.

  10. SINGLE-SHELL TANKS LEAK INTEGRITY ELEMENTS/SX FARM LEAK CAUSES AND LOCATIONS - 12127

    Energy Technology Data Exchange (ETDEWEB)

    VENETZ TJ; WASHENFELDER D; JOHNSON J; GIRARDOT C

    2012-01-25

    Washington River Protection Solutions, LLC (WRPS) developed an enhanced single-shell tank (SST) integrity project in 2009. An expert panel on SST integrity was created to provide recommendations supporting the development of the project. One primary recommendation was to expand the leak assessment reports (substitute report or LD-1) to include leak causes and locations. The recommendation has been included in the M-045-9IF Hanford Federal Facility Agreement and Consent Order (Tri-Party Agreement) as one of four targets relating to SST leak integrity. The 241-SX Farm (SX Farm) tanks with leak losses were addressed on an individual tank basis as part of LD-1. Currently, 8 out of 23 SSTs that have been reported to having a liner leak are located in SX Farm. This percentage was the highest compared to other tank farms which is why SX Farm was analyzed first. The SX Farm is comprised of fifteen SSTs built 1953-1954. The tanks are arranged in rows of three tanks each, forming a cascade. Each of the SX Farm tanks has a nominal I-million-gal storage capacity. Of the fifteen tanks in SX Farm, an assessment reported leak losses for the following tanks: 241-SX-107, 241-SX-108, 241-SX-109, 241-SX-111, 241-SX-112, 241-SX-113, 241-SX-114 and 241-SX-115. The method used to identify leak location consisted of reviewing in-tank and ex-tank leak detection information. This provided the basic data identifying where and when the first leaks were detected. In-tank leak detection consisted of liquid level measurement that can be augmented with photographs which can provide an indication of the vertical leak location on the sidewall. Ex-tank leak detection for the leaking tanks consisted of soil radiation data from laterals and drywells near the tank. The in-tank and ex-tank leak detection can provide an indication of the possible leak location radially around and under the tank. Potential leak causes were determined using in-tank and ex-tank information that is not directly related to

  11. Water stress detection using radar

    NARCIS (Netherlands)

    van Emmerik, T.H.M.

    2017-01-01

    Vegetation is a crucial part of the water and carbon cycle. Through photosynthesis carbon is assimilated for biomass production, and oxygen is released into the atmosphere. During this process, water is transpired through the stomata, and is redistributed in the plant. Transpired water is refilled

  12. Water Detection Based on Color Variation

    Science.gov (United States)

    Rankin, Arturo L.

    2012-01-01

    This software has been designed to detect water bodies that are out in the open on cross-country terrain at close range (out to 30 meters), using imagery acquired from a stereo pair of color cameras mounted on a terrestrial, unmanned ground vehicle (UGV). This detector exploits the fact that the color variation across water bodies is generally larger and more uniform than that of other naturally occurring types of terrain, such as soil and vegetation. Non-traversable water bodies, such as large puddles, ponds, and lakes, are detected based on color variation, image intensity variance, image intensity gradient, size, and shape. At ranges beyond 20 meters, water bodies out in the open can be indirectly detected by detecting reflections of the sky below the horizon in color imagery. But at closer range, the color coming out of a water body dominates sky reflections, and the water cue from sky reflections is of marginal use. Since there may be times during UGV autonomous navigation when a water body does not come into a perception system s field of view until it is at close range, the ability to detect water bodies at close range is critical. Factors that influence the perceived color of a water body at close range are the amount and type of sediment in the water, the water s depth, and the angle of incidence to the water body. Developing a single model of the mixture ratio of light reflected off the water surface (to the camera) to light coming out of the water body (to the camera) for all water bodies would be fairly difficult. Instead, this software detects close water bodies based on local terrain features and the natural, uniform change in color that occurs across the surface from the leading edge to the trailing edge.

  13. ALIBABA, an assistance system for the detection of confinement leaks in a PWR reactor; ALIBABA, un systeme d`aide a la detection des voies de fuites du confinement sur un reacteur a eau sous pression

    Energy Technology Data Exchange (ETDEWEB)

    Bedier, P.O.; Libmann, M. [CEA Centre d`Etudes de Saclay, 91 - Gif-sur-Yvette (France). Dept. de Mecanique et de Technologie

    1995-12-31

    The objective of the Crisis Technical Center (CTC) of the French Institute for Nuclear Protection and Safety (IPSN) is to estimates the consequences of a given nuclear accident on the populations and the environment. ALIBABA is a data processing tool available at the CTC and devoted to the detection of confinement leaks in 900 MWe PWR reactors using the activity values measured by the captors of the installation. The heart of this expert system is a structural and functional representation of the different components directly involved in the leak detection (isolating valves, ventilation systems, electric boards etc..). This tool can manage the availability of each component to make qualitative and quantitative balance-sheets. This paper presents the ALIBABA software, an industrial prototype realized with the SPIRAL knowledge base systems generator at the CEA Reactor Studies and Applied Mathematics Service (SERMA) and commercialized by CRIL-Ingenierie Society. It describes the techniques used for the modeling of PWR systems and for the visualization of the survey. The functionality of the man-machine interface is discussed and the means used for the validation of the software are summarized. (J.S.). 6 refs.

  14. Water Detection Based on Object Reflections

    Science.gov (United States)

    Rankin, Arturo L.; Matthies, Larry H.

    2012-01-01

    Water bodies are challenging terrain hazards for terrestrial unmanned ground vehicles (UGVs) for several reasons. Traversing through deep water bodies could cause costly damage to the electronics of UGVs. Additionally, a UGV that is either broken down due to water damage or becomes stuck in a water body during an autonomous operation will require rescue, potentially drawing critical resources away from the primary operation and increasing the operation cost. Thus, robust water detection is a critical perception requirement for UGV autonomous navigation. One of the properties useful for detecting still water bodies is that their surface acts as a horizontal mirror at high incidence angles. Still water bodies in wide-open areas can be detected by geometrically locating the exact pixels in the sky that are reflecting on candidate water pixels on the ground, predicting if ground pixels are water based on color similarity to the sky and local terrain features. But in cluttered areas where reflections of objects in the background dominate the appearance of the surface of still water bodies, detection based on sky reflections is of marginal value. Specifically, this software attempts to solve the problem of detecting still water bodies on cross-country terrain in cluttered areas at low cost.

  15. Optical detection of glyphosate in water

    Science.gov (United States)

    de Góes, R. E.; Possetti, G. R. C.; Muller, M.; Fabris, J. L.

    2017-04-01

    This work shows preliminary results of the detection of Glyphosate in water by using optical fiber spectroscopy. A colloid with citrate-caped silver nanoparticles was employed as substrate for the measurements. A cross analysis between optical absorption and inelastic scattering evidenced a controlled aggregation of the sample constituents, leading to the possibility of quantitative detection of the analyte. The estimate limit of detection for Glyphosate in water for the proposed sensing scheme was about 1.7 mg/L.

  16. DETECTION OF OIL POLLUTION HOTSPOTS AND LEAK SOURCES THROUGH THE QUANTITATIVE ASSESSMENT OF THE PERSISTENCE AND TEMPORAL REPETITION OF REGULAR OIL SPILLS IN THE CASPIAN SEA USING REMOTE SENSING AND GIS

    OpenAIRE

    E. R. Bayramov; Buchroithner, M. F.; Bayramov, R. V.

    2015-01-01

    The main goal of this research was to detect oil spills, to determine the oil spill frequencies and to approximate oil leak sources around the Oil Rocks Settlement, the Chilov and Pirallahi Islands in the Caspian Sea using 136 multi-temporal ENVISAT Advanced Synthetic Aperture Radar Wide Swath Medium Resolution Images acquired during 2006-2010. The following oil spill frequencies were observed around the Oil Rocks Settlement, the Chilov and Pirallahi Islands: 2-10 (3471.04 sq. km....

  17. Daytime Water Detection Based on Color Variation

    Science.gov (United States)

    Rankin, Arturo L.; Matthies, Larry H.

    2010-01-01

    Robust water detection is a critical perception requirement for unmanned ground vehicle (UGV) autonomous navigation. This is particularly true in wide open areas where water can collect in naturally occurring terrain depressions during periods of heavy precipitation and form large water bodies (such as ponds). At far range, reflections of the sky provide a strong cue for water. But at close range, the color coming out of a water body dominates sky reflections and the water cue from sky reflections is of marginal use. We model this behavior by using water body intensity data from multiple frames of RGB imagery to estimate the total reflection coefficient contribution from surface reflections and the combination of all other factors. Then we describe an algorithm that uses one of the color cameras in a forward- looking, UGV-mounted stereo-vision perception system to detect water bodies in wide open areas. This detector exploits the knowledge that the change in saturation-to-brightness ratio across a water body from the leading to trailing edge is uniform and distinct from other terrain types. In test sequences approaching a pond under clear, overcast, and cloudy sky conditions, the true positive and false negative water detection rates were (95.76%, 96.71%, 98.77%) and (0.45%, 0.60%, 0.62%), respectively. This software has been integrated on an experimental unmanned vehicle and field tested at Ft. Indiantown Gap, PA.

  18. Detection of water molecules in inert gas based plasma by the ratios of atomic spectral lines

    Science.gov (United States)

    Bernatskiy, A. V.; Ochkin, V. N.

    2017-01-01

    A new approach is considered to detect the water leaks in inert plasma-forming gas present in the reactor chamber. It is made up of the intensity ratio of D α and H α spectral lines in combination with O, Ar and Xe lines intensity. The concentrations of H2O, O, H and D particles have been measured with high sensitivity. At the D2 admixture pressure {{p}{{\\text{D}\\text{2}}}}   =  0.025 mbar, we used the acquisition time of 10 s to measure the rate of water molecules injected from the outside, Γ0  =  1.4 · 10-9 mbar · m3 · s-1, and the incoming water molecules to plasma, Γ  =  5 ·10-11 mbar · m3 · s-1. The scaling proves that at small D2 admixtures (10-4 mbar), the leaks with the rates Γ0  ≈  6 · 10-12 mbar · m3 · s-1 and Γ  ≈  2 · 10-13 mbar · m3 · s-1 can be detected and measured. The difference between Γ0 and Γ values is due to the high degree of H2O dissociation, which can be up to 97-98%.

  19. Deep Water Munitions Detection System

    Science.gov (United States)

    2010-03-01

    signal to noise ratios which are shown in Figure 5. The signal to noise was calculated using an algorithm that is part of the Oasis montaj software...using an algorithm that is part of the Oasis montaj software suite. The signal strength of an anomaly is calculated as the sum of the squares of...Process Software extension for Geosoft Oasis Montaj , version 6.4, May 28, 2007 8. DeProspo,D. and R. DiMarco, “Automatic Detection and

  20. Scanning, standoff TDLAS leak imaging and quantification

    Science.gov (United States)

    Wainner, Richard T.; Aubut, Nicholas F.; Laderer, Matthew C.; Frish, Michael B.

    2017-05-01

    This paper reports a novel quantitative gas plume imaging tool, based on active near-infrared Backscatter Tunable Diode Laser Absorption Spectroscopy (b-TDLAS) technology, designed for upstream natural gas leak applications. The new tool integrates low-cost laser sensors with video cameras to create a highly sensitive gas plume imager that also quantifies emission rate, all in a lightweight handheld ergonomic package. It is intended to serve as a lower-cost, higherperformance, enhanced functionality replacement for traditional passive non-quantitative mid-infrared Optical Gas Imagers (OGI) which are utilized by industry to comply with natural gas infrastructure Leak Detection and Repair (LDAR) requirements. It addresses the need for reliable, robust, low-cost sensors to detect and image methane leaks, and to quantify leak emission rates, focusing on inspections of upstream oil and gas operations, such as well pads, compressors, and gas plants. It provides: 1) Colorized quantified images of path-integrated methane concentration. The images depict methane plumes (otherwise invisible to the eye) actively interrogated by the laser beam overlaid on a visible camera image of the background. The detection sensitivity exceeds passive OGI, thus simplifying the manual task of leak detection and location; and 2) Data and algorithms for using the quantitative information gathered by the active detection technique to deduce plume flux (i.e. methane emission rate). This key capability will enable operators to prioritize leak repairs and thereby minimize the value of lost product, as well as to quantify and minimize greenhouse gas emissions, using a tool that meets EPA LDAR imaging equipment requirements.

  1. SEALING SIMULATED LEAKS

    Energy Technology Data Exchange (ETDEWEB)

    Michael A. Romano

    2004-09-01

    This report details the testing equipment, procedures and results performed under Task 7.2 Sealing Simulated Leaks. In terms of our ability to seal leaks identified in the technical topical report, Analysis of Current Field Data, we were 100% successful. In regards to maintaining seal integrity after pigging operations we achieved varying degrees of success. Internal Corrosion defects proved to be the most resistant to the effects of pigging while External Corrosion proved to be the least resistant. Overall, with limitations, pressure activated sealant technology would be a viable option under the right circumstances.

  2. In-Space Distributed Fiber Optic Hydrogen Leak Sensor Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Broadband Photonics Inc. proposes development of a patent-pending distributed fiber optic sensor for in-space hydrogen leak detection. Reliable and fast detection of...

  3. Margins in high temperature leak-before-break assessments

    Energy Technology Data Exchange (ETDEWEB)

    Budden, P.J.; Hooton, D.G.

    1997-04-01

    Developments in the defect assessment procedure R6 to include high-temperature mechanisms in Leak-before-Break arguments are described. In particular, the effect of creep on the time available to detect a leak and on the crack opening area, and hence leak rate, is discussed. The competing influence of these two effects is emphasized by an example. The application to Leak-before-Break of the time-dependent failure assessment diagram approach for high temperature defect assessment is then outlined. The approach is shown to be of use in assessing the erosion of margins by creep.

  4. The leak location package for assessment of the time-frequency correlation method for leak location

    Science.gov (United States)

    Faerman, V. A.; Cheremnov, A. G.; Avramchuk, V. S.; Shepetovsky, D. V.

    2017-01-01

    The paper describes the simplest implementation of a software and hardware package for acoustic correlation leak location and results of its performance assessment for location of water leaks from a metallic pipe in laboratory conditions. A distinctive feature of this leak locator is the use of the software based on the time-frequency correlation analysis of signals, which was proposed in our previous papers. Comparative analysis results are given for the information content of classical and time-frequency cross-correlation functions as obtained during processing of experimental data. The results obtained justify comparatively higher efficiency of a time-frequency cross correlation method to solve the leak location task. Improved efficiency is determined by bandpass filtration embedded into the time-frequency cross-correlation function calculation.

  5. Prediction of Gas Leak Tightness of Superplastically Formed Products

    NARCIS (Netherlands)

    Snippe, Q.H.C.; Meinders, Vincent T.; Barlat, F; Moon, Y.H.; Lee, M.G.

    2010-01-01

    In some applications, in this case an aluminium box in a subatomic particle detector containing highly sensitive detecting devices, it is important that a formed sheet should show no gas leak from one side to the other. In order to prevent a trial-and-error procedure to make this leak tight box, a

  6. Operational Philosophy Concerning Manned Spacecraft Cabin Leaks

    Science.gov (United States)

    DeSimpelaere, Edward

    2011-01-01

    The last thirty years have seen the Space Shuttle as the prime United States spacecraft for manned spaceflight missions. Many lessons have been learned about spacecraft design and operation throughout these years. Over the next few decades, a large increase of manned spaceflight in the commercial sector is expected. This will result in the exposure of commercial crews and passengers to many of the same risks crews of the Space Shuttle have encountered. One of the more dire situations that can be encountered is the loss of pressure in the habitable volume of the spacecraft during on orbit operations. This is referred to as a cabin leak. This paper seeks to establish a general cabin leak response philosophy with the intent of educating future spacecraft designers and operators. After establishing a relative definition for a cabin leak, the paper covers general descriptions of detection equipment, detection methods, and general operational methods for management of a cabin leak. Subsequently, all these items are addressed from the perspective of the Space Shuttle Program, as this will be of the most value to future spacecraft due to similar operating profiles. Emphasis here is placed upon why and how these methods and philosophies have evolved to meet the Space Shuttle s needs. This includes the core ideas of: considerations of maintaining higher cabin pressures vs. lower cabin pressures, the pros and cons of a system designed to feed the leak with gas from pressurized tanks vs. using pressure suits to protect against lower cabin pressures, timeline and consumables constraints, re-entry considerations with leaks of unknown origin, and the impact the International Space Station (ISS) has had to the standard Space Shuttle cabin leak response philosophy. This last item in itself includes: procedural management differences, hardware considerations, additional capabilities due to the presence of the ISS and its resource, and ISS docking/undocking considerations with a

  7. Quartz enhanced photoacoustic leak sensor for mechatronic components

    Science.gov (United States)

    Sampaolo, A.; Patimisco, P.; Giglio, M.; Calabrese, P. P.; Chieco, L.; Scamarcio, G.; Tittel, F. K.; Spagnolo, V.

    2016-02-01

    We report the first demonstration of a leak sensor based on a mid-IR quartz-enhanced photoacoustic (QEPAS) spectroscopic technique. A QEPAS sensor was integrated in a vacuum seal test station for mechatronic components. The laser source is a quantum cascade laser emitting at 10.56 μm, resonant with a strong absorption band of sulfur hexafluoride (SF6), which was selected as target gas for leak detection. The minimum detectable concentration of the QEPAS sensor is 6.9 ppb with an integration time of 1 s. This detection sensitivity allowed to measure SF6 leak flows as low as 3x10-5 standard cm3.

  8. Natural gas leak mapper

    Science.gov (United States)

    Reichardt, Thomas A [Livermore, CA; Luong, Amy Khai [Dublin, CA; Kulp, Thomas J [Livermore, CA; Devdas, Sanjay [Albany, CA

    2008-05-20

    A system is described that is suitable for use in determining the location of leaks of gases having a background concentration. The system is a point-wise backscatter absorption gas measurement system that measures absorption and distance to each point of an image. The absorption measurement provides an indication of the total amount of a gas of interest, and the distance provides an estimate of the background concentration of gas. The distance is measured from the time-of-flight of laser pulse that is generated along with the absorption measurement light. The measurements are formated into an image of the presence of gas in excess of the background. Alternatively, an image of the scene is superimosed on the image of the gas to aid in locating leaks. By further modeling excess gas as a plume having a known concentration profile, the present system provides an estimate of the maximum concentration of the gas of interest.

  9. Detection of Oil Pollution Hotspots and Leak Sources Through the Quantitative Assessment of the Persistence and Temporal Repetition of Regular Oil Spills in the Caspian Sea Using Remote Sensing and GIS

    Science.gov (United States)

    Bayramov, E. R.; Buchroithner, M. F.; Bayramov, R. V.

    2015-08-01

    The main goal of this research was to detect oil spills, to determine the oil spill frequencies and to approximate oil leak sources around the Oil Rocks Settlement, the Chilov and Pirallahi Islands in the Caspian Sea using 136 multi-temporal ENVISAT Advanced Synthetic Aperture Radar Wide Swath Medium Resolution Images acquired during 2006-2010. The following oil spill frequencies were observed around the Oil Rocks Settlement, the Chilov and Pirallahi Islands: 2-10 (3471.04 sq. km.), 11-20 (971.66 sq. km.), 21-50 (692.44 sq. km.), 51-128 (191.38 sq. km.). The most critical oil leak sources with the frequency range of 41-128 were observed at the Oil Rocks Settlement. The exponential regression analysis between wind speeds and oil slick areas detected from 136 multi-temporal ENVISAT images revealed the regression coefficient equal to 63%. The regression model showed that larger oil spill areas were observed with decreasing wind speeds. The spatiotemporal patterns of currents in the Caspian Sea explained the multi-directional spatial distribution of oil spills around Oil Rocks Settlement, the Chilov and Pirallahi Islands. The linear regression analysis between detected oil spill frequencies and predicted oil contamination probability by the stochastic model showed the positive trend with the regression coefficient of 30%.

  10. Water Pollution Detection by Reflectance Measurements

    Science.gov (United States)

    Goolsby, A. D.

    1971-01-01

    Measurement of the intensity of light reflected from various planar liquid surfaces has been performed. The results of this brief study show that the presence of a film of foreign material floating on a reference substrate is easily detected by reflectance measurement if the two liquids possess significantly different refractive indices, for example, oil (n = 1.40) and water (n = 1.33). Additional study of various optical configurations, and the building and testing of a prototype monitoring device revealed that the method is sufficiently practical for application to continuous water quality monitoring.

  11. [Detection of Cryptosporidium in subterranean drinking water].

    Science.gov (United States)

    de Abramovich, B L; Lura de Calafell, M C; Haye, M A; Nepote, A; Argañara, M F

    1996-01-01

    The objective of the present work has been to determine the role of drinking water of subterranean origin in the transmission of enteroparasitosis. The samples were obtained from wells and tanks supplying population areas in Santa Fe province. The physico-chemical and bacteriological parameters were all determined. The detection of parasites was carried out by means of filtration, the subsequent washing of the filters with a Tween 80 solution and the concentration of the remaining liquid which was then submitted to microscopic examination. This examination was made for both fresh samples and samples stained with permanent and differential staining techniques. Cryptosporidium spp. oocysts were found in the water which supplies one of those population areas. The bacteriological examination revealed the presence of total coliforms but neither chemical contamination parameters nor faecalis coliforms were found. We conclude that the absence of the latter is not enough to discard the presence of parasites and that protective measures of the water supply must be implemented.

  12. Rapid Migration of Radionuclides Leaked from High-Level Water Tanks; A Study of Salinity Gradients, Wetted Path Geometry and Water Vapor Transport

    Energy Technology Data Exchange (ETDEWEB)

    Anderson l. Ward; Glendon W. Gee; John S. Selker; Clay Cooper

    2002-04-24

    The basis of this study was the hypothesis that the physical and chemical properties of hypersaline tank waste could lead to wetting from instability and fingered flow following a tank leak. Thus, the goal of this project was to develop an understanding of the impacts of the properties of hypersaline fluids on transport through the unsaturated zone beneath Hanford's Tank Farms. There were three specific objectives (i) to develop an improved conceptualization of hypersaline fluid transport in laboratory (ii) to identify the degree to which field conditions mimic the flow processes observed in the laboratory and (iii) to provide a validation data set to establish the degree to which the conceptual models, embodied in a numerical simulator, could explain the observed field behavior. As hypothesized, high ionic strength solutions entering homogeneous pre-wetted porous media formed unstable wetting fronts atypical of low ionic strength infiltration. In the field, this mechanism could for ce flow in vertical flow paths, 5-15 cm in width, bypassing much of the media and leading to waste penetration to greater depths than would be predicted by current conceptual models. Preferential flow may lead to highly accelerated transport through large homogeneous units, and must be included in any conservative analysis of tank waste losses through coarse-textured units. However, numerical description of fingered flow using current techniques has been unreliable, thereby precluding tank-scale 3-D simulation of these processes. A new approach based on nonzero, hysteretic contract angles and fluid-dependent liquid entry has been developed for the continuum scale modeling of fingered flow. This approach has been coupled with and adaptive-grid finite-difference solver to permit the prediction of finger formation and persistence form sub centimeter scales to the filed scale using both scalar and vector processors. Although laboratory experiments demonstrated that elevated surface

  13. Rapid Migration of Radionuclides Leaked from High-Level Water Tanks: A Study of Salinity Gradients, Wetted Path Geometry and Water Vapor Transport

    Energy Technology Data Exchange (ETDEWEB)

    Anderson L. Ward; Glendon W. Gee; John S. Selker; Caly Cooper

    2002-04-24

    The basis of this study was the hypothesis that the physical and chemical properties of hypersaline tank waste could lead to wetting from instability and fingered flow following a tank leak. Thus, the goal of this project was to develop an understanding of the impacts of the properties of hypersaline fluids on transport through the unsaturated zone beneath Hanford's Tank Farms. There were three specific objectives (i) to develop an improved conceptualization of hypersaline fluid transport in laboratory (ii) to identify the degree to which field conditions mimic the flow processes observed in the laboratory and (iii) to provide a validation data set to establish the degree to which the conceptual models, embodied in a numerical simulator, could explain the observed field behavior. As hypothesized, high ionic strength solutions entering homogeneous pre-wetted porous media formed unstable wetting fronts a typical of low ionic strength infiltration. In the field, this mechanism could force flow in vertical flow paths, 5-15 cm in width, bypassing much of the media and leading to waste penetration to greater depths than would be predicted by current conceptual models. Preferential flow may lead to highly accelerated transport through large homogeneous units, and must be included in any conservative analysis of tank waste losses through coarse-textured units. However, numerical description of fingered flow using current techniques has been unreliable, thereby precluding tank-scale 3-D simulation of these processes. A new approach based on nonzero, hysteretic contact angles and fluid-dependent liquid entry has been developed for the continuum scale modeling of fingered flow. This approach has been coupled with and adaptive-grid finite-difference solver to permit the prediction of finger formation and persistence form sub centimeter scales to the filed scale using both scalar and vector processors. Although laboratory experiments demonstrated that elevated surface

  14. Summary of QRL 7-8 Repair and Re-installation Leak Test Results

    CERN Document Server

    Kos, N; CERN. Geneva. TE Department

    2009-01-01

    This note describes the leak tests that have been performed during the repair and re-installation of QRL sector 7-8 during 2005 and 2006. The leak tests were performed in UX65, where the pipe elements were refurbished before re-installation, and in the tunnel. A variety of leaks have been detected, localised and repaired in the tunnel, including weld defects, accidentally drilled holes and imported leaks in previously tested components.

  15. Methods and apparatus for measuring small leaks from carbon dioxide sequestration facilities

    Energy Technology Data Exchange (ETDEWEB)

    Nelson, Jr., David D.; Herndon, Scott C.

    2018-01-02

    In one embodiment, a CO.sub.2 leak detection instrument detects leaks from a site (e.g., a CO.sub.2 sequestration facility) using rapid concentration measurements of CO.sub.2, O.sub.2 and optionally water concentration that are achieved, for example, using laser spectroscopy (e.g. direct absorption laser spectroscopy). Water vapor in the sample gas may not be removed, or only partially removed. The sample gas may be collected using a multiplexed inlet assembly from a plurality of locations. CO.sub.2 and O.sub.2 concentrations may be corrected based on the water concentration. A resulting dataset of the CO.sub.2 and O.sub.2 concentrations is analyzed over time intervals to detect any changes in CO.sub.2 concentration that are not anti-correlated with O.sub.2 concentration, and to identify a potential CO.sub.2 leak in response thereto. The analysis may include determining eddy covariance flux measurements of sub-surface potential carbon.

  16. Deconstructing Gender Stereotypes in Leak

    Directory of Open Access Journals (Sweden)

    Nengah Bawa Atmadja

    2015-05-01

    Full Text Available The belief of Balinese people towards leak still survive. Leak is a magic based on durgaism that can transform a person from human to another form, such as apes, pigs, etc. People tend to regard leak as evil. In general, the evilness is constructed in gender stereotypes, so it is identified that leak are always women. This idea is a power game based on the ideology of patriarchy that provides legitimacy for men to dominate women with a plea for social harmony. As a result, women are marginalized in the Balinese society. Women should be aware of so it would provide encouragement for them to make emancipatory changes dialogically. Kepercayaan orang Bali terhadap leak tetap bertahan sampai saat ini. Leak adalah sihir yang berbasiskan durgaisme yang dapat mengakibatkan seseorang bisa merubah bentuk dari manusia ke wujud yang lain, misalnya kera, babi, dll. Leak termasuk magi hitam sehingga dinilai bersifat jelek. Pada umumnya perempuan diidentikkan dengan leak sehingga melahirkan asumsi yang bermuatan steriotip gender bahwa leak = perempuan. Gagasan ini merupakan permainan kekuasaan berbasis ideologi patriarkhi dan sekaligus memberikan legitimasi bagi laki-laki untuk menguasai perempuan dengan dalih demi keharmonisan sosial. Akibatnya, perempuan menjadi termarginalisasi pada masyarakat Bali.  Perempuan harus menyadarinya sehingga memberikan dorongan bagi mereka untuk melakukan perubahan secara dialogis emansipatoris.

  17. Research project RoboGas{sup Inspector}. Gas leak detection with autonomous mobile robots; Forschungsprojekt RoboGas{sup Inspector}. Gaslecksuche mit autonomen mobilen Robotern

    Energy Technology Data Exchange (ETDEWEB)

    Habib, Abdelkarim [BAM Bundesanstalt fuer Materialforschung und -pruefung, Berlin (Germany); Bonow, Gero; Kroll, Andreas [Fachgebiet Mess- und Regelungstechnik, Universitaet Kassel, Kassel (Germany); Hegenberg, Jens; Schmidt, Ludger [Fachgebiet Mensch-Maschine-Systemtechnik, Universitaet Kassel, Kassel (Germany); Barz, Thomas; Schulz, Dirk [Fraunhofer FKIE, Unbemannte Systeme, Wachtberg (Germany)

    2013-05-15

    As part of the promotional program AUTONOMIK of the Federal Ministry of Economics and Technology (Berlin, Federal Republic of Germany) a consortium of nine project partners developed a prototype of an autonomous mobile robot looking for gas leaks in extended industrial equipment. The autonomous mobility of the system for any systems was implemented using different types of sensors for self-localization and navigation. The tele-operation enables a manual intervention in the process. The robot performs inspection tasks in industrial plants by means of video technology and remote gas measurement technology without driving into the possible risk areas and without the presence of humans. The robot can be used for routine inspections of facilities or for the targeted inspection of specific plant components. Thanks to the remote sensing technique also plant components can be inspected which are difficult to be inspected due to their limited accessibility by conventional measurement techniques.

  18. Using hyperspectral plant signatures for CO2 leak detection during the 2008 ZERT CO2 sequestration field experiment in Bozeman, Montana

    Energy Technology Data Exchange (ETDEWEB)

    Male, E.J.; Pickles, W.L.; Silver, E.A.; Hoffmann, G.D.; Lewicki, J.; Apple, M.; Repasky, K.; Burton, E.A.

    2009-11-01

    Hyperspectral plant signatures can be used as a short-term, as well as long-term (100-yr timescale) monitoring technique to verify that CO2 sequestration fields have not been compromised. An influx of CO2 gas into the soil can stress vegetation, which causes changes in the visible to nearinfrared reflectance spectral signature of the vegetation. For 29 days, beginning on July 9th, 2008, pure carbon dioxide gas was released through a 100-meter long horizontal injection well, at a flow rate of 300 kg/day. Spectral signatures were recorded almost daily from an unmown patch of plants over the injection with a ''FieldSpec Pro'' spectrometer by Analytical Spectral Devices, Inc. Measurements were taken both inside and outside of the CO2 leak zone to normalize observations for other environmental factors affecting the plants.

  19. Detection of traces of triclosan in water

    Science.gov (United States)

    Marques, Inês; Magalhâes-Mota, Gonçalo; Pires, Filipa; Sério, Susana; Ribeiro, Paulo A.; Raposo, Maria

    2017-11-01

    Triclosan (TCS) is an antibacterial agent widely used in soaps, toothpastes and first-aid products, which presents several drawbacks related with its noxious effects on the biological systems. As this compound is stable and lipophilic, its consumption in large scale is a great deal of concern, particularly because it has been widely found in river water, lake water, sediments, fish and human milk. Therefore, it is urgent to produce an effective, economic, disposable sensor to detect TCS in complex matrixes. This work explores the electronic tongue sensor concept towards the detection of pico-molar concentrations of TCS in aqueous medium. For that an array of sensor devices consisting of bare interdigitated electrodes (IEs) and covered with different layer-by-layer (LBL) films was developed being its response analyzed by impedance spectroscopy. The LbL films were prepared from poly(ethyleneimine) (PEI), graphene oxide (GO), chitosan (Chi), poly[1-[4-(3-carboxy-4-hydroxyphenylazo) benzene sulfonamido]-1,2-ethanediyl, sodium salt] (PAZO) and poly (allylamine hydrochloride) (PAH). Results allowed to select an adequate sensor array to be used for TCS detection in aqueous solutions within the 10-12 M-10-6 M concentrations range, either by using electrical resistance or electrical capacitance at fixed frequencies as key transducing variables. Principal Component Analysis (PCA) data treatment allowed the discrimination of triclosan solution and of methanol aqueous solutions used in TCS solutions preparation, suggesting that the methodology used in this work can be used to detect TCS in complex matrix solutions.

  20. CSNI specialist meeting on leak-before-break in nuclear reactor piping: proceedings

    Energy Technology Data Exchange (ETDEWEB)

    1984-08-01

    On September 1 and 2, 1983, the CSNI subcommittee on primary system integrity held a special meeting in Monterey, California, on the subject of leak-before-break in nuclear reactor piping systems. The purpose of the meeting was to provide an international forum for the exchange of ideas, positions, and research results; to identify areas requiring additional research and development; and to determine the general attitude toward acceptance of the leak-before-break concept. The importance of the leak-before-break issue was evidenced by excellent attendance at the meeting and through active participation by the meeting attendees. Approximately 125 people representing fifteen different nations attended the meeting. The meeting was divided into four technical sessions addressing the following areas: Application of Piping Fracture Mechanics to Leak-Before Break, Leak Rate and Leak Detection, Leak-Before-Break Studies, Methods and Results, Current and Proposed Positions on Leak-Before-Break.

  1. Tank 241-A-105 leak assessment

    Energy Technology Data Exchange (ETDEWEB)

    1991-06-01

    Tank 241-A-105 is one of 149 single shell tanks constructed at Hanford to contain and store highly radioactive wastes originating from the processing of spent nuclear reactor fuel. Radiation detection and temperature monitoring devices installed beneath the tank indicate that several episodes of leakage of waste from the tank have occurred. The aim of this study was to evaluate the previous estimates and reanalyze the data to provide a more accurate estimate of leakage from the tank. The principal conclusions of this study are as follows: Earlier investigators estimated leakage prior to August 1968 at 5,000 to 15,000 gallons. Their estimate appears reasonable. Leakage while the tank was being sluiced (8/68--11/70) probably exceeded 5,000 gallons, but probably did not exceed 30,000 gallons. Insufficient data are available to be more precise. Cooling water added to the tank during the sprinkling phase (11/70 -- 12/78) was approximately 610,000 gallons. Sufficient heat was generated in the tank to evaporate most, and perhaps nearly all, of this water. Radionuclides escaping into the soil under the tank cannot be estimated directly because of many uncertainties. Based on a range of leakage from 10,000 to 45,000 gallons, assumed compositions, and decayed to 1/1/91, radioactivity under the tank is expected to be in the range of 85,000--760,000 curies. Measured radiation peaks were nearly all located directly below the perimeter of the tank and, except in rare cases, they showed no tendency to spread horizontally. Moreover, the maximum radiation readings detected are a very small fraction of the radiation reading in the tank. This is the basis for the conclusion that the rate of leakage and, most likely, the quantity leaked, was small. 51 refs., 5 figs., 3 tabs.

  2. The Demonstration of a Robotic External Leak Locator on the International Space Station

    Science.gov (United States)

    Naids, Adam; Rossetti, Dino; Bond, Tim; Johnson, Brien; Huang, Alvin; Deal, Alexandra; Fox, Katie; Heiser, Michael; Hartman, William; Mikatarian, Ronald

    2017-01-01

    The International Space Station (ISS) and all currently conceivable future manned spacecraft are susceptible to mission impacts due to fluid/gas leaks to the exterior environment. For example, there is a well-known risk of ammonia leaks from the ISS External Thermal Control System loops and currently no method to locate them. It was, therefore, critical to develop a method for detecting and locating leaks to preserve vehicle health. The Robotic External Leak Locator (RELL) was developed and deployed to the ISS to provide this capability. An on-orbit validation and demonstration was successfully completed in December 2016 and leak locating operations occurred in February 2017. This paper discusses the results of those exercises including measurements of the environment around ISS, detection of the small ammonia leak and implementation of leak locating methodologies.

  3. Systems and Methods for Automated Water Detection Using Visible Sensors

    Science.gov (United States)

    Rankin, Arturo L. (Inventor); Matthies, Larry H. (Inventor); Bellutta, Paolo (Inventor)

    2016-01-01

    Systems and methods are disclosed that include automated machine vision that can utilize images of scenes captured by a 3D imaging system configured to image light within the visible light spectrum to detect water. One embodiment includes autonomously detecting water bodies within a scene including capturing at least one 3D image of a scene using a sensor system configured to detect visible light and to measure distance from points within the scene to the sensor system, and detecting water within the scene using a processor configured to detect regions within each of the at least one 3D images that possess at least one characteristic indicative of the presence of water.

  4. 33 CFR 127.1203 - Gas detection.

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Gas detection. 127.1203 Section 127.1203 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED... (b) of this section must serve to detect leaks, check structures for gas accumulations, and indicate...

  5. Air-leak effects on ear-canal acoustic absorbance.

    Science.gov (United States)

    Groon, Katherine A; Rasetshwane, Daniel M; Kopun, Judy G; Gorga, Michael P; Neely, Stephen T

    2015-01-01

    Accurate ear-canal acoustic measurements, such as wideband acoustic admittance, absorbance, and otoacoustic emissions, require that the measurement probe be tightly sealed in the ear canal. Air leaks can compromise the validity of the measurements, interfere with calibrations, and increase variability. There are no established procedures for determining the presence of air leaks or criteria for what size leak would affect the accuracy of ear-canal acoustic measurements. The purpose of this study was to determine ways to quantify the effects of air leaks and to develop objective criteria to detect their presence. Air leaks were simulated by modifying the foam tips that are used with the measurement probe through insertion of thin plastic tubing. To analyze the effect of air leaks, acoustic measurements were taken with both modified and unmodified foam tips in brass-tube cavities and human ear canals. Measurements were initially made in cavities to determine the range of critical leaks. Subsequently, data were collected in ears of 21 adults with normal hearing and normal middle-ear function. Four acoustic metrics were used for predicting the presence of air leaks and for quantifying these leaks: (1) low-frequency admittance phase (averaged over 0.1-0.2 kHz), (2) low-frequency absorbance, (3) the ratio of compliance volume to physical volume (CV/PV), and (4) the air-leak resonance frequency. The outcome variable in this analysis was the absorbance change (Δabsorbance), which was calculated in eight frequency bands. The trends were similar for both the brass cavities and the ear canals. ΔAbsorbance generally increased with air-leak size and was largest for the lower frequency bands (0.1-0.2 and 0.2-0.5 kHz). Air-leak effects were observed in frequencies up to 10 kHz, but their effects above 1 kHz were unpredictable. These high-frequency air leaks were larger in brass cavities than in ear canals. Each of the four predictor variables exhibited consistent dependence on

  6. Nanomaterial-enabled Rapid Detection of Water Contaminants.

    Science.gov (United States)

    Mao, Shun; Chang, Jingbo; Zhou, Guihua; Chen, Junhong

    2015-10-28

    Water contaminants, e.g., inorganic chemicals and microorganisms, are critical metrics for water quality monitoring and have significant impacts on human health and plants/organisms living in water. The scope and focus of this review is nanomaterial-based optical, electronic, and electrochemical sensors for rapid detection of water contaminants, e.g., heavy metals, anions, and bacteria. These contaminants are commonly found in different water systems. The importance of water quality monitoring and control demands significant advancement in the detection of contaminants in water because current sensing technologies for water contaminants have limitations. The advantages of nanomaterial-based sensing technologies are highlighted and recent progress on nanomaterial-based sensors for rapid water contaminant detection is discussed. An outlook for future research into this rapidly growing field is also provided. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  7. Natural gas pipeline leaks across Washington, DC.

    Science.gov (United States)

    Jackson, Robert B; Down, Adrian; Phillips, Nathan G; Ackley, Robert C; Cook, Charles W; Plata, Desiree L; Zhao, Kaiguang

    2014-01-01

    Pipeline safety in the United States has increased in recent decades, but incidents involving natural gas pipelines still cause an average of 17 fatalities and $133 M in property damage annually. Natural gas leaks are also the largest anthropogenic source of the greenhouse gas methane (CH4) in the U.S. To reduce pipeline leakage and increase consumer safety, we deployed a Picarro G2301 Cavity Ring-Down Spectrometer in a car, mapping 5893 natural gas leaks (2.5 to 88.6 ppm CH4) across 1500 road miles of Washington, DC. The δ(13)C-isotopic signatures of the methane (-38.2‰ ± 3.9‰ s.d.) and ethane (-36.5 ± 1.1 s.d.) and the CH4:C2H6 ratios (25.5 ± 8.9 s.d.) closely matched the pipeline gas (-39.0‰ and -36.2‰ for methane and ethane; 19.0 for CH4/C2H6). Emissions from four street leaks ranged from 9200 to 38,200 L CH4 day(-1) each, comparable to natural gas used by 1.7 to 7.0 homes, respectively. At 19 tested locations, 12 potentially explosive (Grade 1) methane concentrations of 50,000 to 500,000 ppm were detected in manholes. Financial incentives and targeted programs among companies, public utility commissions, and scientists to reduce leaks and replace old cast-iron pipes will improve consumer safety and air quality, save money, and lower greenhouse gas emissions.

  8. The leak microstructure

    Indian Academy of Sciences (India)

    The capabilities of a new microstructure, anode point based, for the detection of gas ionizing radiations are presented. For every single detected ionizing radiation it gives a pair of 'induced' charges (anodic and cathodic) of the same amount (pulses of the same amplitudes), of opposite sign, with the same collection time and ...

  9. The leak microstructure

    Indian Academy of Sciences (India)

    Abstract. The capabilities of a new microstructure, anode point based, for the detection of gas ion- izing radiations are presented. For every single detected ionizing radiation it gives a pair of 'induced' charges (anodic and cathodic) of the same amount (pulses of the same amplitudes), of opposite sign, with the same ...

  10. Measurement of Submerged Oil/Gas Leaks using ROV Video

    Science.gov (United States)

    Shaffer, Franklin; de Vera, Giorgio; Lee, Kenneth; Savas, Ömer

    2013-11-01

    Drilling for oil or gas in the Gulf of Mexico is increasing rapidly at depths up to three miles. The National Commission on the Deepwater Horizon Oil Leak concluded that inaccurate estimates of the leak rate from the Deepwater Horizon caused an inadequate response and attempts to cap the leak to fail. The first response to a submerged oil/gas leak will be to send a Remotely Operated Vehicle (ROV) down to view the leak. During the response to the Deepwater Horizon crisis, the authors Savas and Shaffer were members of the Flow Rate Technical Group's Plume Team who used ROV video to develop the FRTG's first official estimates of the oil leak rate. Savas and Shaffer developed an approach using the larger, faster jet features (e.g., turbulent eddies, vortices, entrained particles) in the near-field developing zone to measure discharge rates. The authors have since used the Berkeley Tow Tank to test this approach on submerged dye-colored water jets and compressed air jets. Image Correlation Velocimetry has been applied to measure the velocity of visible features. Results from tests in the Berkeley Tow Tank and submerged oil jets in the OHMSETT facility will be presented.

  11. Influence of Crack Morphology on Leak Before Break Margins

    Energy Technology Data Exchange (ETDEWEB)

    Weilin Zang (Inspecta Technology AB, Stockholm (SE))

    2007-11-15

    The purpose of the project is to evaluate the deterministic LBB-margins for different pipe systems in a Swedish PWR-plant and using different crack morphology parameters. Results: - The influence of crack morphology on Leak Before Break (LBB) margins is studied. The subject of the report is a number of LBB-submittals to SKI where deterministic LBB-margins are reported. These submittals typically uses a surface roughness of 0.0762 mm (300 microinch) and number of turns equal to zero and an in-house code for the leak rate evaluations. The present report has shown that these conditions give the largest LBB-margins both in terms of the quotient between the critical crack length and the leakage crack size and for the leak rate margin. - Crack morphology parameters have a strong influence on the leak rate evaluations. Using the SQUIRT code and more recent recommendations for crack morphology parameters, it is shown that in many cases the evaluated margins, using 1 gpm as the reference leak rate detection limit, are below the safety factor of 2 on crack size and 10 on leak rate, which is generally required for LBB approval. - The effect of including weld residual stresses on the LBB margins is also investigated. It is shown that for the two examples studied, weld residual stresses were important for the small diameter thin wall pipe whereas it was negligible for the large diameter thick wall pipe which had a self-balanced weld residual stress distribution

  12. Methane Leaks from Natural Gas Systems Follow Extreme Distributions.

    Science.gov (United States)

    Brandt, Adam R; Heath, Garvin A; Cooley, Daniel

    2016-11-15

    Future energy systems may rely on natural gas as a low-cost fuel to support variable renewable power. However, leaking natural gas causes climate damage because methane (CH 4 ) has a high global warming potential. In this study, we use extreme-value theory to explore the distribution of natural gas leak sizes. By analyzing ∼15 000 measurements from 18 prior studies, we show that all available natural gas leakage data sets are statistically heavy-tailed, and that gas leaks are more extremely distributed than other natural and social phenomena. A unifying result is that the largest 5% of leaks typically contribute over 50% of the total leakage volume. While prior studies used log-normal model distributions, we show that log-normal functions poorly represent tail behavior. Our results suggest that published uncertainty ranges of CH 4 emissions are too narrow, and that larger sample sizes are required in future studies to achieve targeted confidence intervals. Additionally, we find that cross-study aggregation of data sets to increase sample size is not recommended due to apparent deviation between sampled populations. Understanding the nature of leak distributions can improve emission estimates, better illustrate their uncertainty, allow prioritization of source categories, and improve sampling design. Also, these data can be used for more effective design of leak detection technologies.

  13. Mitigated Transfer Line Leaks that Result in Surface Pools and Spray Leaks into Pits

    Energy Technology Data Exchange (ETDEWEB)

    HEY, B.E.

    1999-12-07

    This analysis provides radiological and toxicological consequence calculations for postulated mitigated leaks during transfers of six waste compositions. Leaks in Cleanout Boxes equipped with supplemental covers and leaks in pits are analyzed.

  14. Strength and leak testing of plasma activated bonded interfaces

    DEFF Research Database (Denmark)

    Visser, M.M.; Weichel, Steen; Reus, Roger De

    2002-01-01

    on detection of changes in membrane deflections. The detection limit for leak was 8E-13 mbar l/s. For comparison, strength and leak tests were also performed with regular fusion bonded wafers annealed at 1100 degreesC. The PAB was found to withstand post-processing steps such as RCA cleaning, 24 h in de......Bond strength and hermeticity of plasma activated bonded (PAB) Si-Si interfaces are reported. Bonding of 100 mm Si(1 0 0) wafers was performed. An average bond strength of 9.0+/-3.9 MPa was achieved without performing any annealing steps. Cavities bonded in vacuum were found to be hermetic based...

  15. Rapid detection of Naegleria fowleri in water distribution pipeline biofilms and drinking water samples.

    Science.gov (United States)

    Puzon, Geoffrey J; Lancaster, James A; Wylie, Jason T; Plumb, Iason J

    2009-09-01

    Rapid detection of pathogenic Naegleria fowler in water distribution networks is critical for water utilities. Current detection methods rely on sampling drinking water followed by culturing and molecular identification of purified strains. This culture-based method takes an extended amount of time (days), detects both nonpathogenic and pathogenic species, and does not account for N. fowleri cells associated with pipe wall biofilms. In this study, a total DNA extraction technique coupled with a real-time PCR method using primers specific for N. fowleri was developed and validated. The method readily detected N. fowleri without preculturing with the lowest detection limit for N. fowleri cells spiked in biofilm being one cell (66% detection rate) and five cells (100% detection rate). For drinking water, the detection limit was five cells (66% detection rate) and 10 cells (100% detection rate). By comparison, culture-based methods were less sensitive for detection of cells spiked into both biofilm (66% detection for pipe wall biofilm samples obtained from a distribution network enabled the detection of N. fowleri in under 6 h, versus 3+ daysforthe culture based method. Further, comparison of the real-time PCR data from the field samples and the standard curves enabled an approximation of N. fowleri cells in the biofilm and drinking water. The use of such a method will further aid water utilities in detecting and managing the persistence of N. fowleri in water distribution networks.

  16. Water in Massive protostellar objects: first detection of THz water maser and water inner abundance.

    Science.gov (United States)

    Herpin, Fabrice

    2014-10-01

    The formation massive stars is still not well understood. Despite numerous water line observations with Herschel telescope, over a broad range of energies, in most of the observed sources the WISH-KP (Water In Star-forming regions with Herschel, Co-PI: F. Herpin) observations were not able to trace the emission from the hot core. Moreover, water maser model predict that several THz water maser should be detectable in these objects. We aim to detect for the first time the THz maser lines o-H2O 8(2,7)- 7(3,4) at 1296.41106 GHz and p-H2O 7(2,6)- 6(3,3) at 1440.78167 GHz as predicted by the model. We propose two sources for a northern flight as first priority and two other sources for a possible southern flight. This will 1) constrain the maser theory, 2) constrain the physical conditions and water abundance in the inner layers of the prostellar environnement. In addition, we will use the p-H2O 3(3,1)- 4(0,4) thermal line at 1893.68651 GHz (L2 channel) in order to probe the physical conditions and water abundance in the inner layers of the prostellar objects where HIFI-Herschel has partially failed.

  17. Mesoscale, Radiometrically Referenced, Multi-Temporal Hyperspectral Data for Co2 Leak Detection by Locating Spatial Variation of Biophysically Relevant Parameters

    Science.gov (United States)

    McCann, Cooper Patrick

    Low-cost flight-based hyperspectral imaging systems have the potential to provide valuable information for ecosystem and environmental studies as well as aide in land management and land health monitoring. This thesis describes (1) a bootstrap method of producing mesoscale, radiometrically-referenced hyperspectral data using the Landsat surface reflectance (LaSRC) data product as a reference target, (2) biophysically relevant basis functions to model the reflectance spectra, (3) an unsupervised classification technique based on natural histogram splitting of these biophysically relevant parameters, and (4) local and multi-temporal anomaly detection. The bootstrap method extends standard processing techniques to remove uneven illumination conditions between flight passes, allowing the creation of radiometrically self-consistent data. Through selective spectral and spatial resampling, LaSRC data is used as a radiometric reference target. Advantages of the bootstrap method include the need for minimal site access, no ancillary instrumentation, and automated data processing. Data from a flight on 06/02/2016 is compared with concurrently collected ground based reflectance spectra as a means of validation achieving an average error of 2.74%. Fitting reflectance spectra using basis functions, based on biophysically relevant spectral features, allows both noise and data reductions while shifting information from spectral bands to biophysical features. Histogram splitting is used to determine a clustering based on natural splittings of these fit parameters. The Indian Pines reference data enabled comparisons of the efficacy of this technique to established techniques. The splitting technique is shown to be an improvement over the ISODATA clustering technique with an overall accuracy of 34.3/19.0% before merging and 40.9/39.2% after merging. This improvement is also seen as an improvement of kappa before/after merging of 24.8/30.5 for the histogram splitting technique

  18. Pressure based leak detection system implanted on the business Unit Exploration and Production of PETROBRAS in Rio Grande do Norte e Ceara; Sistema de deteccao de vazamentos em dutos baseado em pressao implantado na Unidade de Negocios de Exploracao e Producao da PETROBRAS no Rio de Grande do Norte e Ceara

    Energy Technology Data Exchange (ETDEWEB)

    Rolim, Tuerte A.; Oliveira, Abenildo A.de [PETROBRAS S.A., Rio de Janeiro, RJ (Brazil)

    2003-07-01

    This paper presents the experience faced by people who works in PETROBRAS Business Unit (UN-RNCE), located in Rio Grande do Norte Province, Brazil, during the implementation of a pipeline leak detection system. That application involved nine multiphase oil pipelines distributed along several production facilities. Because of the emergency after the leakage that polluted the Guanabara bay and due to the two phases and multi phases pipelines characteristics, the UN-RNCE decided to apply the Pressure Point Analysis (PPA) technology in order to detect leakages. It is a statistical method for leak detection e uses a very simple instrumentation which facilitates the installation and maintenance. However, in order to get the best performance of the system, it is necessary to know thoroughly the whole process and have a fast and reliable SCADA system for long distance communication. Finally it will be shown the test results, the recommendations to expand the system and the conclusions. (author)

  19. Leak testing plan for the Oak Ridge National Laboratory liquid low- level waste system (active tanks). Volume 1, Regulatory background and plan approach; Volume 2, Methods, protocols, and schedules; Volume 3, Evaluation of the ORNL/LT-823DP differential pressure leak detection method

    Energy Technology Data Exchange (ETDEWEB)

    Douglas, D. G.; Wise, R. F.; Starr, J. W.; Maresca, Jr, J. W. [Vista Research, Inc., Mountain View, CA (United States)

    1992-06-01

    A leak testing plan for a portion of the Liquid Low-Level Waste (LLLW) system at the Oak Ridge National Laboratory (ORNL) is provided in the two volumes that form this document. This plan was prepared in response to the requirements of the Federal Facilities Agreement (FFA) between the US Department of Energy and two other agencies, the US Environmental Protection Agency (EPA) and the Tennessee Department of Environment and Conservation (TDEC). The effective date of this agreement was 1 January 1992. The LLLW system is an interconnected complex of tanks and pipelines. The FFA distinguishes four different categories of tank and pipeline systems within this complex: new systems (Category A), doubly contained systems (Category B), singly contained systems (Category C), and inactive systems (Category D). The FFA's specific requirements for leak testing of the Category C systems is addressed in this plan. The plan also addresses leak testing of the Category B portions of the LLLW system. Leak testing of the Category B components was brought into the plan to supplement the secondary containment design demonstration effort that is under way for these components.

  20. Noninvasive detection of nanoparticle clustering by water proton NMR

    Energy Technology Data Exchange (ETDEWEB)

    Taraban, Marc B.; Truong, Huy C.; Ilavsky, Jan; DePaz, Roberto A.; Lobo, Brian; Yu, Y. Bruce

    2017-06-01

    It is shown that water proton NMR can detect uncontrolled clustering of inert nanoparticles (NPs) formulated as aqueous suspensions. The clustering of NPs causes the compartmentalization of water molecules, leading to accelerated proton spin de-coherence, and hence, much faster water transverse relaxation rates. The results suggest that water proton NMR can be used to noninvasively inspect NP products by commercial end users and researchers.

  1. Detection and Enumeration of Microorganisms in Water and Waste Waters.

    Science.gov (United States)

    Andrews, S.

    1980-01-01

    Presents and explains analytical procedures for the detection and quantitative enumeration of bacteria which constitute or are indicators of fecal contamination of aquatic environments. Tests are given for Escherichia coli, fecal Streptococci, Clostridium perfringens, and Salmonella. (WB)

  2. CT findings suggesting anastomotic leak and predicting the recovery period following gastric surgery

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Tae Ho; Kim, Jung Hoon; Shin, Cheong-Il; Kim, Se Hyung; Han, Joon Koo; Choi, Byung Ihn [Seoul National University College of Medicine, Department of Radiology, Institute of Radiation Medicine, Jongno-gu, Seoul (Korea, Republic of)

    2015-07-15

    To assess diagnostic performance of routine CT for detecting anastomotic leak after gastric surgery, and analyse the relationship between recovery period and CT findings. We included 179 patients who underwent immediate CT and fluoroscopy after gastric surgery. Two reviewers retrospectively rated the possibility of leak on CT using a five-point scale focused on predefined CT findings. They also evaluated CT findings. Patients were categorised as: Group I, leak on fluoroscopy; Group II, possible leak on CT but negative on fluoroscopy; Group III, no leak. We analysed the relationship between recovery period and group. Area under the curve for detecting leak on CT was 0.886 in R1 and 0.668 in R2 with moderate agreement (k = 0.482). Statistically common CT findings for leak included discontinuity, large amount of air-fluid and wall thickening at anastomosis site (p < 0.05). Discontinuity at anastomosis site and a large air-fluid collection were independently associated with leak (p < 0.05). The recovery period including hospitalisation and postoperative fasting period was longer in Group I than Group II or III (p < 0.05). Group II showed a longer recovery period than Group III (p < 0.05). Postoperative routine CT was useful for predicting anastomotic leak using specific findings, and for predicting length of recovery period. (orig.)

  3. Stochastic Consequence Analysis for Waste Leaks

    Energy Technology Data Exchange (ETDEWEB)

    HEY, B.E.

    2000-05-31

    This analysis evaluates the radiological consequences of potential Hanford Tank Farm waste transfer leaks. These include ex-tank leaks into structures, underneath the soil, and exposed to the atmosphere. It also includes potential misroutes, tank overflow

  4. Anaerobic polymers as high vacuum leak sealants

    Science.gov (United States)

    Kendall, B. R. F.

    1982-01-01

    Anaerobic polymers are useful as solventless leak sealants with good vacuum properties at moderate temperatures. Loctite 290 can seal leaks in a range generally encountered in carefully constructed ultrahigh vacuum and high vacuum systems. It was found that small leaks are sealed best under vacuum, whereas large leaks should be sealed at atmospheric pressure. The high-temperature behavior of Loctite 290 is limited by its fast cure, which prevents deep penetration into small leaks; cracking eventually occurs at the entrance to the leak. Repeated thermal cycling to about 300 C is possible, however, provided viscosity, curing time, and leak size are properly matched to ensure penetration into the body of the leak. This may require special formulations for high temperature vacuum applications.

  5. Presidential Leaks: Rhetoric and Mediated Political Knowledge.

    Science.gov (United States)

    Erickson, Keith V.

    1989-01-01

    Argues that presidential leaks constitute rhetorical acts, enabling administrations to exercise a variety of rhetorically potent options not afforded by the public forum. Proposes a typology of presidential leaks and analyzes their rhetorical functions, benefits, and liabilities. (MM)

  6. 40 CFR 63.424 - Standards: Equipment leaks.

    Science.gov (United States)

    2010-07-01

    ... implement an instrument leak monitoring program that has been demonstrated to the Administrator as at least equivalent. (g) Owners and operators shall not allow gasoline to be handled in a manner that would result in... recycling devices, such as oil/water separators. ...

  7. Evaluation of ATP measurements to detect microbial ingress by wastewater and surface water in drinking water.

    Science.gov (United States)

    Vang, Óluva K; Corfitzen, Charlotte B; Smith, Christian; Albrechtsen, Hans-Jørgen

    2014-11-01

    Fast and reliable methods are required for monitoring of microbial drinking water quality in order to protect public health. Adenosine triphosphate (ATP) was investigated as a potential real-time parameter for detecting microbial ingress in drinking water contaminated with wastewater or surface water. To investigate the ability of the ATP assay in detecting different contamination types, the contaminant was diluted with non-chlorinated drinking water. Wastewater, diluted at 10(4) in drinking water, was detected with the ATP assay, as well as 10(2) to 10(3) times diluted surface water. To improve the performance of the ATP assay in detecting microbial ingress in drinking water, different approaches were investigated, i.e. quantifying microbial ATP or applying reagents of different sensitivities to reduce measurement variations; however, none of these approaches contributed significantly in this respect. Compared to traditional microbiological methods, the ATP assay could detect wastewater and surface water in drinking water to a higher degree than total direct counts (TDCs), while both heterotrophic plate counts (HPC 22 °C and HPC 37 °C) and Colilert-18 (Escherichia coli and coliforms) were more sensitive than the ATP measurements, though with much longer response times. Continuous sampling combined with ATP measurements displays definite monitoring potential for microbial drinking water quality, since microbial ingress in drinking water can be detected in real-time with ATP measurements. The ability of the ATP assay to detect microbial ingress is influenced by both the ATP load from the contaminant itself and the ATP concentration in the specific drinking water. Consequently, a low ATP concentration of the specific drinking water facilitates a better detection of a potential contamination of the water supply with the ATP assay. Copyright © 2014 Elsevier Ltd. All rights reserved.

  8. CT and MR image fusion for CSF leak diagnosis

    Science.gov (United States)

    Hu, Yangqiu; Haynor, David R.; Maravilla, Kenneth R.

    2008-03-01

    The diagnosis of CSF leak using MR images alone is difficult due to the inherently poor bony information on MR images. While CT images show bones exquisitely, they lack the soft tissue contrast that is important for detecting CSF leak. For these reasons, CT cisternography has been the preferred modality for CSF leak diagnosis despite its invasiveness. We propose a method to fuse the CT and MR images to combine the complementary information from each modality, which we believe will help with the diagnosis and surgical planning for patients with CSF leak, and potentially reduce/replace the use of CT cisternography. In the first step, the user identifies three roughly corresponding points on both the CT and MR images. A GUI was designed that allows the user to quickly navigate through the images by reslicing the volumes interactively. After finding the CT and MR slices at approximately the same anatomical position, the user places three markers to represent the same spatial location. In the second step, a generalized Procrustes transform is used to compute an initial transformation that aligns the CT and MR, which is then optimized using mutual information maximization. The CT is registered with the MR using the optimal transformation found, and the bony masks determined from thresholding CT intensity are blended with MR images. Initial results suggest that CT/MR fusion images are superior to unprocessed CT and MR images in diagnosing CSF leak, and a formal clinical evaluation is being planned to assess the efficacy of fusion images.

  9. Location and repair of air leaks in the ATF (Advanced Toroidal Facility) vacuum vessel

    Energy Technology Data Exchange (ETDEWEB)

    Schwenterly, S.W.; Gabbard, W.A.; Schaich, C.R.; Yarber, J.L. (Oak Ridge National Lab., TN (USA))

    1989-01-01

    On the basis of partial pressure rate-of-rise and base pressure measurements, it was determined that the Advanced Toroidal Facility (ATF) vacuum vessel had an air leak in the low 10{sup -4} mbar-{ell}/s range. Pinpointing this leak by conventional helium leak-checking procedures was not possible, because large portions of the outside of the vessel are covered by the helcial field coils and a structural shell. Various alternative leak-detection schemes that were considered are summarized and their advantages and disadvantages noted. In the method ultimately employed, gun-rubber patches of various sizes ranging from 12.7 by 12.7 cm to 20.3 by 30.5 cm were positioned on the inside surfaces of the vessel and evacuated by the leak detector (LD). After roughly 5% of the surface was inspected in this way, a leak of > 10{sup -5} mbar-{ell}/s was discovered and localized to an area of 5 by 5 cm. Dye penetrant applied to this area disclosed three pinholes. Two small slag pockets were discovered while these points were being ground out. After these were rewelded, no furthered leakage could be found in the repaired area. Global leak rates measured after the machine was reevacuated indicated that this leak was about 30% of the overall leak rate. 1 ref., 5 figs., 1 tab.

  10. Autologous conjunctival resurfacing of leaking filtering blebs.

    Science.gov (United States)

    Harris, L D; Yang, G; Feldman, R M; Fellman, R L; Starita, R J; Lynn, J; Chuang, A Z

    2000-09-01

    To present a case series of a new technique to repair late bleb leaks. Retrospective, noncomparative, consecutive case series. Forty-seven autologous conjunctival resurfacings of late bleb leaks were performed by four surgeons at two institutions. Autologous conjunctival grafts were placed over existing de-epithelialized leaking blebs. Leak-free, Seidel-negative blebs and controlled glaucoma. After a mean follow-up of 14 +/- 12 months, one patient continued to have bleb leak at the last follow-up, and one frank leak resolved with aqueous suppression. Intraocular pressure increased from 6.6 +/- 4.4 mmHg (0.13 glaucoma medications) to 11.9 +/- 4.1 mmHg (0.41 glaucoma medications). Conjunctival resurfacing with autologous tissue is an effective technique to repair late bleb leaks.

  11. Water Feature Extraction and Change Detection Using Multitemporal Landsat Imagery

    Directory of Open Access Journals (Sweden)

    Komeil Rokni

    2014-05-01

    Full Text Available Lake Urmia is the 20th largest lake and the second largest hyper saline lake (before September 2010 in the world. It is also the largest inland body of salt water in the Middle East. Nevertheless, the lake has been in a critical situation in recent years due to decreasing surface water and increasing salinity. This study modeled the spatiotemporal changes of Lake Urmia in the period 2000–2013 using the multi-temporal Landsat 5-TM, 7-ETM+ and 8-OLI images. In doing so, the applicability of different satellite-derived indexes including Normalized Difference Water Index (NDWI, Modified NDWI (MNDWI, Normalized Difference Moisture Index (NDMI, Water Ratio Index (WRI, Normalized Difference Vegetation Index (NDVI, and Automated Water Extraction Index (AWEI were investigated for the extraction of surface water from Landsat data. Overall, the NDWI was found superior to other indexes and hence it was used to model the spatiotemporal changes of the lake. In addition, a new approach based on Principal Components of multi-temporal NDWI (NDWI-PCs was proposed and evaluated for surface water change detection. The results indicate an intense decreasing trend in Lake Urmia surface area in the period 2000–2013, especially between 2010 and 2013 when the lake lost about one third of its surface area compared to the year 2000. The results illustrate the effectiveness of the NDWI-PCs approach for surface water change detection, especially in detecting the changes between two and three different times, simultaneously.

  12. Detecting the cold water reservoir in a protoplanetary disk.

    Science.gov (United States)

    Hogerheijde, M.; Bergin, E. A.; Brinch, C.; Cleeves, L.; Fogel, J.; Blake, G.; Cernicharo, J.; Dominik, C.; Lis, D. C.; Melnick, G.; Neufeld, D.; Panic, O.; Pearson, J.; Kristensen, L.; Yildiz, U.; van Dishoeck, E.

    2011-05-01

    Water plays a pivotal role in planet-forming disks around newly formed stars. Frozen out onto dust grains in the cold and dense disk interior, water ice likely aids coagulation of grains and enables planet formation. The ice mantles are also a locus of complex chemistry, and provide a potentially rich source of water to be delivered to early Earth-like planets. The observational evidence for the presence of water in protoplanetary disks has so-far been limited to mid-infrared emission lines of hot water in the inner regions of several disks (<3 AU) and a few rare occasions of the water-ice feature at 3 μm in absorption or in scattered light. The infrared water emission lines indicate that the water gas-phase abundance drops sharply outside a few AU, possibly because the water freezes out efficiently onto cold dust grains outside the `snow line'. We present the first detections of the rotational ground-state emission lines of both spin-isomers of water, obtained with the Heterodyne Instrument for the Far-Infrared (HIFI) on-board the Herschel Space Observatory toward the disk around the young, low-mass star TW Hya. These velocity-resolved spectra show that cold water vapor is present throughout the entire radial extent of the disk. Efficient photodesorption of water-ice molecules by stellar ultraviolet radiation is a likely explanation for the presence of water vapor beyond a few AU, and our detections proof that a water-ice reservoir extends throughout the disk. The strength of the emission lines is lower than expected based on recent laboratory measurements of photodesorption and a fiducial model for the TW Hya disk. This suggests that grains carrying as much as 80--90% of the water ice content have settled toward the disk mid-plane, and are outside the reach of the stellar ultraviolet radiation. From our calculations and the detection of both ortho- and para-water, we derive the `spin temperature' of the cold water vapor in the TW Hya disk, which we compare to

  13. Leak-Tight Welding Experience from the Industrial Assembly of the LHC Cryostats at CERN

    CERN Document Server

    Bourcey, N; Chiggiato, P; Limon, P; Mongelluzzo, A; Musso, G; Poncet, A; Parma, V

    2008-01-01

    The assembly of the approximately 1700 LHC main ring cryostats at CERN involved extensive welding of cryogenic lines and vacuum vessels. More than 6 km of welding requiring leak tightness to a rate better than 1.10-9 mbar.l.s-1 on stainless steel and aluminium piping and envelopes was made, essentially by manual welding but also making use of orbital welding machines. In order to fulfil the safety regulations related to pressure vessels and to comply with the leak-tightness requirements of the vacuum systems of the machine, welds were executed according to high qualification standards and following a severe quality assurance plan. Leak detection by He mass spectrometry was extensively used. Neon leak detection was used successfully to locate leaks in the presence of helium backgrounds. This paper presents the quality assurance strategy adopted for welds and leak detection. It presents the statistics of non-conformities on welds and leaks detected throughout the entire production and the advances in the use...

  14. Contamination event detection using multiple types of conventional water quality sensors in source water.

    Science.gov (United States)

    Liu, Shuming; Che, Han; Smith, Kate; Chen, Lei

    2014-08-01

    Early warning systems are often used to detect deliberate and accidental contamination events in a water system. Conventional methods normally detect a contamination event by comparing the predicted and observed water quality values from one sensor. This paper proposes a new method for event detection by exploring the correlative relationships between multiple types of conventional water quality sensors. The performance of the proposed method was evaluated using data from contaminant injection experiments in a laboratory. Results from these experiments demonstrated the correlative responses of multiple types of sensors. It was observed that the proposed method could detect a contamination event 9 minutes after the introduction of lead nitrate solution with a concentration of 0.01 mg L(-1). The proposed method employs three parameters. Their impact on the detection performance was also analyzed. The initial analysis showed that the correlative response is contaminant-specific, which implies that it can be utilized not only for contamination detection, but also for contaminant identification.

  15. Analyzing User Awareness of Privacy Data Leak in Mobile Applications

    Directory of Open Access Journals (Sweden)

    Youngho Kim

    2015-01-01

    Full Text Available To overcome the resource and computing power limitation of mobile devices in Internet of Things (IoT era, a cloud computing provides an effective platform without human intervention to build a resource-oriented security solution. However, existing malware detection methods are constrained by a vague situation of information leaks. The main goal of this paper is to measure a degree of hiding intention for the mobile application (app to keep its leaking activity invisible to the user. For real-world application test, we target Android applications, which unleash user privacy data. With the TaintDroid-ported emulator, we make experiments about the timing distance between user events and privacy leaks. Our experiments with Android apps downloaded from the Google Play show that most of leak cases are driven by user explicit events or implicit user involvement which make the user aware of the leakage. Those findings can assist a malware detection system in reducing the rate of false positive by considering malicious intentions. From the experiment, we understand better about app’s internal operations as well. As a case study, we also presents a cloud-based dynamic analysis framework to perform a traffic monitor.

  16. Extreme Water Deficit in Brazil Detected from Space

    Science.gov (United States)

    Vieira Getirana

    2016-01-01

    Extreme droughts have caused significant socioeconomic and environmental damage worldwide. In Brazil, ineffective energy development and water management policies have magnified the impacts of recent severe droughts, which include massive agricultural losses, water supply restrictions, and energy rationing. Spaceborne remote sensing data advance our understanding of the spatiotemporal variability of large-scale droughts and enhance the detection and monitoring of extreme water-related events. In this study, data derived from the Gravity Recovery and Climate Experiment (GRACE) mission are used to detect and quantify an extended major drought over eastern Brazil and provide estimates of impacted areas and region-specific water deficits. Two structural breakpoint detection methods were applied to time series of GRACE-based terrestrial water storage anomalies (TWSA), determining when two abrupt changes occurred. One, in particular, defines the beginning of the current drought. Using TWSA, a water loss rate of 26.1 cmyr21 over southeastern Brazil was detected from 2012 to 2015. Based on analysis of Global Land Data Assimilation System(GLDAS) outputs, the extreme drought is mostly related to lower-than-usual precipitation rates, resulting in high soil moisture depletion and lower-than-usual rates of evapotranspiration. A reduction of 2023 of precipitation over an extended period of 3 years is enough to raise serious water scarcity conditions in the country. Correlations between monthly time series of both grid-based TWSA and ground-based water storage measurements at 16 reservoirs located within southeastern Brazil varied from 0.42 to 0.82. Differences are mainly explained by reservoir sizes and proximity to the drought nucleus.

  17. Using Fluorescent Viruses for Detecting Bacteria in Water

    Science.gov (United States)

    Tabacco, Mary Beth; Qian, Xiaohua; Russo, Jaimie A.

    2009-01-01

    A method of detecting water-borne pathogenic bacteria is based partly on established molecular-recognition and fluorescent-labeling concepts, according to which bacteria of a species of interest are labeled with fluorescent reporter molecules and the bacteria can then be detected by fluorescence spectroscopy. The novelty of the present method lies in the use of bacteriophages (viruses that infect bacteria) to deliver the fluorescent reporter molecules to the bacteria of the species of interest.

  18. Gastric leaks post sleeve gastrectomy: Review of its prevention and management

    Science.gov (United States)

    Abou Rached, Antoine; Basile, Melkart; El Masri, Hicham

    2014-01-01

    Gastric sleeve gastrectomy has become a frequent bariatric procedure. Its apparent simplicity hides a number of serious, sometimes fatal, complications. This is more important in the absence of an internationally adopted algorithm for the management of the leaks complicating this operation. The debates exist even regarding the definition of a leak, with several classification systems that can be used to predict the cause of the leak, and also to determine the treatment plan. Causes of leak are classified as mechanical, technical and ischemic causes. After defining the possible causes, authors went into suggesting a number of preventive measures to decrease the leak rate, including gentle handling of tissues, staple line reinforcement, larger bougie size and routine use of methylene blue test per operatively. In our review, we noticed that the most important clinical sign or symptom in patients with gastric leaks are fever and tachycardia, which mandate the use of an abdominal computed tomography, associated with an upper gastrointrstinal series and/or gastroscopy if no leak was detected. After diagnosis, the management of leak depends mainly on the clinical condition of the patient and the onset time of leak. It varies between prompt surgical intervention in unstable patients and conservative management in stable ones in whom leaks present lately. The management options include also endoscopic interventions with closure techniques or more commonly exclusion techniques with an endoprosthesis. The aim of this review was to highlight the causes and thus the prevention modalities and find a standardized algorithm to deal with gastric leaks post sleeve gastrectomy. PMID:25320526

  19. Method for HEPA filter leak scanning with differentiating aerosol detector

    Energy Technology Data Exchange (ETDEWEB)

    Kovach, B.J.; Banks, E.M.; Wikoff, W.O. [NUCON International, Inc., Columbus, OH (United States)

    1997-08-01

    While scanning HEPA filters for leaks with {open_quotes}Off the Shelf{close_quote} aerosol detection equipment, the operator`s scanning speed is limited by the time constant and threshold sensitivity of the detector. This is based on detection of the aerosol density, where the maximum signal is achieved when the scanning probe resides over the pinhole longer than several detector time-constants. Since the differential value of the changing signal can be determined by observing only the first small fraction of the rising signal, using a differentiating amplifier will speed up the locating process. The other advantage of differentiation is that slow signal drift or zero offset will not interfere with the process of locating the leak, since they are not detected. A scanning hand-probe attachable to any NUCON{reg_sign} Aerosol Detector displaying the combination of both aerosol density and differentiated signal was designed. 3 refs., 1 fig.

  20. Detection of the water reservoir in a forming planetary system.

    Science.gov (United States)

    Hogerheijde, Michiel R; Bergin, Edwin A; Brinch, Christian; Cleeves, L Ilsedore; Fogel, Jeffrey K J; Blake, Geoffrey A; Dominik, Carsten; Lis, Dariusz C; Melnick, Gary; Neufeld, David; Panić, Olja; Pearson, John C; Kristensen, Lars; Yildiz, Umut A; van Dishoeck, Ewine F

    2011-10-21

    Icy bodies may have delivered the oceans to the early Earth, yet little is known about water in the ice-dominated regions of extrasolar planet-forming disks. The Heterodyne Instrument for the Far-Infrared on board the Herschel Space Observatory has detected emission lines from both spin isomers of cold water vapor from the disk around the young star TW Hydrae. This water vapor likely originates from ice-coated solids near the disk surface, hinting at a water ice reservoir equivalent to several thousand Earth oceans in mass. The water's ortho-to-para ratio falls well below that of solar system comets, suggesting that comets contain heterogeneous ice mixtures collected across the entire solar nebula during the early stages of planetary birth.

  1. Intermediate-Scale Laboratory Experiments of Subsurface Flow and Transport Resulting from Tank Leaks

    Energy Technology Data Exchange (ETDEWEB)

    Oostrom, Martinus; Wietsma, Thomas W.

    2014-09-30

    Washington River Protection Solutions contracted with Pacific Northwest National Laboratory to conduct laboratory experiments and supporting numerical simulations to improve the understanding of water flow and contaminant transport in the subsurface between waste tanks and ancillary facilities at Waste Management Area C. The work scope included two separate sets of experiments: •Small flow cell experiments to investigate the occurrence of potential unstable fingering resulting from leaks and the limitations of the STOMP (Subsurface Transport Over Multiple Phases) simulator to predict flow patterns and solute transport behavior under these conditions. Unstable infiltration may, under certain conditions, create vertically elongated fingers potentially transporting contaminants rapidly through the unsaturated zone to groundwater. The types of leak that may create deeply penetrating fingers include slow release, long duration leaks in relatively permeable porous media. Such leaks may have occurred below waste tanks at the Hanford Site. •Large flow experiments to investigate the behavior of two types of tank leaks in a simple layered system mimicking the Waste Management Area C. The investigated leaks include a relatively large leak with a short duration from a tank and a long duration leak with a relatively small leakage rate from a cascade line.

  2. Direct detection of the Enceladus water torus with Herschel

    NARCIS (Netherlands)

    Hartogh, P.; Lellouch, E.; Moreno, R.; Bockelee-Morvan, D.; Biver, N.; Cassidy, T.; Rengel, M.; Jarchow, C.; Cavalie, T.; Crovisier, J.; Helmich, F. P.; Kidger, M.

    Cryovolcanic activity near the south pole of Saturn's moon Enceladus produces plumes of H2O-dominated gases and ice particles, which escape and populate a torus-shaped cloud. Using submillimeter spectroscopy with Herschel, we report the direct detection of the Enceladus water vapor torus in four

  3. Detection of the water reservoir in a forming planetary system

    NARCIS (Netherlands)

    Hogerheijde, M.R.; Bergin, E.A.; Brinch, C.; Cleeves, L.I.; Fogel, J. K.J.; Blake, G.A.; Dominik, C.; Lis, D.C.; Melnick, G.; Neufeld, D.; Panić, O.; Pearson, J.C.; Kristensen, L.; Yıldız, U.A.; van Dishoeck, E.F.

    2011-01-01

    Icy bodies may have delivered the oceans to the early Earth, yet little is known about water in the ice-dominated regions of extrasolar planet-forming disks. The Heterodyne Instrument for the Far-Infrared on board the Herschel Space Observatory has detected emission lines from both spin isomers of

  4. Evaluation of ATP measurements to detect microbial ingress by wastewater and surface water in drinking water

    DEFF Research Database (Denmark)

    Vang, Óluva Karin; Corfitzen, Charlotte B.; Smith, Christian

    2014-01-01

    in this respect. Compared to traditional microbiological methods, the ATP assay could detect wastewater and surface water in drinking water to a higher degree than total direct counts (TDCs), while both heterotrophic plate counts (HPC 22 °C and HPC 37 °C) and Colilert-18 (Escherichia coli and coliforms) were more...

  5. Detection of the Water Reservoir in a Forming Planetary System

    Science.gov (United States)

    Hogerheijde, Michiel R.; Bergin, Edwin A.; Brinch, Christian; Cleeves, L. Ilsedore; Fogel, Jeffrey K. J.; Blake, Geoffrey A.; Dominik, Carsten; Lis, Dariusz C.; Melnick, Gary; Neufeld, David; Panić, Olja; Pearson, John C.; Kristensen, Lars; Yıldız, Umut A.; van Dishoeck, Ewine F.

    2011-10-01

    Icy bodies may have delivered the oceans to the early Earth, yet little is known about water in the ice-dominated regions of extrasolar planet-forming disks. The Heterodyne Instrument for the Far-Infrared on board the Herschel Space Observatory has detected emission lines from both spin isomers of cold water vapor from the disk around the young star TW Hydrae. This water vapor likely originates from ice-coated solids near the disk surface, hinting at a water ice reservoir equivalent to several thousand Earth oceans in mass. The water’s ortho-to-para ratio falls well below that of solar system comets, suggesting that comets contain heterogeneous ice mixtures collected across the entire solar nebula during the early stages of planetary birth.

  6. Detection of Coxiella burnetii in Urban River Water.

    Science.gov (United States)

    D'Ugo, Emilio; Sdanganelli, Massimo; Grasso, Cinzia; Magurano, Fabio; Marcheggiani, Stefania; Boots, Bas; Baggieri, Melissa; Mancini, Laura

    2017-07-01

    Previous molecular-based studies have identified microorganisms of zoonotic and human nature in surface waters. Contaminated water can lead to human health issues, and the detection of pathogenic microorganisms is a valuable tool for the prevention of their spread. Water samples were taken from the River Tiber in and out of the city of Rome. Genetic analysis of the sequences obtained showed the presence of Coxiella burnetii in both the analyzed sites. Blast analysis showed that two sequences were identical to each other. Sequences from the polluted site showed high homology with different strains of C. burnetii. In this article, we report for the first time the presence of C. burnetii in environmental waters.

  7. Optical Fluorescence Detected from X-ray Irradiated Liquid Water.

    Science.gov (United States)

    Hans, Andreas; Ozga, Christian; Seidel, Robert; Schmidt, Philipp; Ueltzhöffer, Timo; Holzapfel, Xaver; Wenzel, Philip; Reiß, Philipp; Pohl, Marvin N; Unger, Isaak; Aziz, Emad F; Ehresmann, Arno; Slavíček, Petr; Winter, Bernd; Knie, André

    2017-03-16

    Despite its importance, the structure and dynamics of liquid water are still poorly understood in many apsects. Here, we report on the observation of optical fluorescence upon soft X-ray irradiation of liquid water. Detection of spectrally resolved fluorescence was achieved by a combination of the liquid microjet technique and fluorescence spectroscopy. We observe a genuine liquid-phase fluorescence manifested by a broad emission band in the 170-340 nm (4-7 eV) photon wavelength range. In addition, another narrower emission near 300 nm can be assigned to the fluorescence of OH (A state) in the gas phase, the emitting species being formed by Auger electrons escaping from liquid water. We argue that the newly observed broad-band emission of liquid water is relevant in search of extraterrestrial life, and we also envision the observed electron-ejection mechanism to find application for exploring solutes at liquid-vapor interfaces.

  8. Method for in-situ detection of tritium in water

    Science.gov (United States)

    Berthold, John W., III; Jeffers, Larry A.

    1999-12-01

    The objective of this project was to design a monitoring system capable of detecting and quantifying tritium in-situ in ground and surface waters, and in water from effluent lines prior to discharge into public waterways. The design work was successfully completed with the predicted capability to detect tritium levels below 20 nanocuries per liter. The designed system was based on the detection of the low energy beta radiation from the radioactive decay of tritium using a special form of scintillating optical fiber directly in contact with the water to be measured. To support the design, laboratory tests were performed in several areas. Different types of scintillating fiber were tested to determine which would provide optimum system performance. The fibers contained a fluor material in a special cladding configuration which optimizes the absorption of beta radiation. The tritium detection system consists of an immersible sensor module containing the optical fiber and detection electronics as well as signal processing electronics. An umbilical cable is used to interconnect the components. The system design goals included optional permanent installation for routine water monitoring in wells, process and effluent lines or as a potential portable survey tool which could be moved from one location to another. Not all the design goals were met due to the large physical size of the immersible sensor module. Discussed in this paper are the design details of the in-situ tritium beta detector, the tests performed, and results obtained. The work was supported by U.S. Department of Energy (DOE) contract number DE-AC21-96MC33128.

  9. Fighting the Epidemic of Nuclear Plant Leaks.

    Science.gov (United States)

    Udell, Richard A.

    1983-01-01

    The current epidemic of steam generator tube leaks alone should put to rest the rosy future once envisioned for nuclear power. It is impossible to regulate quality into a nuclear plant; it must be built and designed that way. The economic impact of the leaks is discussed. (RM)

  10. ISOLDE Off-line Gas Leak Upgrade

    CERN Document Server

    Nielsen, Kristoffer Bested

    2017-01-01

    This study investigates gas injection system of the ISOLDE Off-line separator. A quadrupole mass spectrometer is used to analysis the composition of the gas. Based on these measurements a contamination of the injected gas is found and a system upgrade is purposed. Furthermore a calibration of the leak rate of the leak valve is made.

  11. Uncommon leaks revealed by low flow anaesthesia

    African Journals Online (AJOL)

    Adele

    TRAVEL FELLOWSHIP. Low flow techniques provide a long duration of reliable anaesthesia at minimal cost. The use of low flows requires a leak free circuit and anaesthetic machine. Should leaks occur during low flow anaesthesia, these will be immediately obvious and rapidly rectified. Anaesthetic machines have been ...

  12. Protecting brazing furnaces from air leaks

    Science.gov (United States)

    Armenoff, C. T.; Mckown, R. D.

    1980-01-01

    Inexpensive inert-atmosphere shielding protects vacuum brazing-furnace components that are likely to spring leak. Pipefittings, gages, and valves are encased in transparent plastic shroud inflated with argon. If leak develops, harmless argon will enter vacuum chamber, making it possible to finish ongoing brazing or heat treatment before shutting down for repair.

  13. PCR detection of Burkholderia multivorans in water and soil samples.

    Science.gov (United States)

    Peeters, Charlotte; Daenekindt, Stijn; Vandamme, Peter

    2016-08-12

    Although semi-selective growth media have been developed for the isolation of Burkholderia cepacia complex bacteria from the environment, thus far Burkholderia multivorans has rarely been isolated from such samples. Because environmental B. multivorans isolates mainly originate from water samples, we hypothesized that water rather than soil is its most likely environmental niche. The aim of the present study was to assess the occurrence of B. multivorans in water samples from Flanders (Belgium) using a fast, culture-independent PCR assay. A nested PCR approach was used to achieve high sensitivity, and specificity was confirmed by sequencing the resulting amplicons. B. multivorans was detected in 11 % of the water samples (n = 112) and 92 % of the soil samples (n = 25) tested. The percentage of false positives was higher for water samples compared to soil samples, showing that the presently available B. multivorans recA primers lack specificity when applied to the analysis of water samples. The results of the present study demonstrate that B. multivorans DNA is commonly present in soil samples and to a lesser extent in water samples in Flanders (Belgium).

  14. Multiple-Feature Extracting Modules Based Leak Mining System Design

    Directory of Open Access Journals (Sweden)

    Ying-Chiang Cho

    2013-01-01

    mining system that is equipped with SQL injection vulnerability detection, by means of an algorithm developed for the web crawler. In addition, we analyze portal sites of the governments of various countries or regions in order to investigate the information leaking status of each site. Subsequently, we analyze the database structure and content of each site, using the data collected. Thus, we make use of practical verification in order to focus on information security and privacy through black-box testing.

  15. An evaluation of certain Salmonella detection methods in surface water.

    Science.gov (United States)

    Bernagozzi, M; Sacchetti, R; Polenta, L

    1996-11-01

    Two different procedures were employed for detecting Salmonella spp. in environmental water samples: a rapid method (enrichment in Salmosyst Broth and plating in Rambach Agar-Merck) and a longer assay (pre-enrichment in Buffered Peptone Water, enrichment in Selenite-Cistyne Broth and plating in Brilliant Green Agar-Difco). The efficiency of microbiological tests was measured by the following criteria: recovery, sensitivity and specificity. The results analysed by the Kendall concordance coefficients demonstrated that the rapid method appeared more effective even if poorly specific.

  16. Leak Tightness of LHC Cold Vacuum Systems

    CERN Document Server

    Cruikshank, P; Maan, M; Mourier, L; Perrier-Cornet, A; Provot, N

    2011-01-01

    The cold vacuum systems of the LHC machine have been in operation since 2008. While a number of acceptable helium leaks were known to exist prior to cool down and have not significantly evolved over the last years, several new leaks have occurred which required immediate repair activities or mitigating solutions to permit operation of the LHC. The LHC vacuum system is described together with a summary and timetable of known air and helium leaks and their impact on the functioning of the cryogenic and vacuum systems. Where leaks have been investigated and repaired, the cause and failure mechanism is described. We elaborate the mitigating solutions that have been implemented to avoid degradation of known leaks and minimize their impact on cryogenic operation and LHC availability, and finally a recall of the consolidation program to be implemented in the next LHC shutdown.

  17. Time-dependent leak behavior of flawed Alloy 600 tube specimens at constant pressure

    Energy Technology Data Exchange (ETDEWEB)

    Bahn, Chi Bum, E-mail: bahn@anl.gov [Argonne National Laboratory, Argonne, IL 60439 (United States); Majumdar, Saurin [Argonne National Laboratory, Argonne, IL 60439 (United States); Harris, Charles [United States Nuclear Regulatory Commission, Rockville, MD 20852 (United States)

    2011-10-15

    Leak rate testing has been performed using Alloy 600 tube specimens with throughwall flaws. Some specimens have shown time-dependent leak behavior at constant pressure conditions. Fractographic characterization was performed to identify the time-dependent crack growth mechanism. The fracture surface of the specimens showed the typical features of ductile fracture, as well as the distinct crystallographic facets, typical of fatigue crack growth at low {Delta}K level. Structural vibration appears to have been caused by the oscillation of pressure, induced by a high-pressure pump used in a test facility, and by the water jet/tube structure interaction. Analyses of the leak behaviors and crack growth indicated that both the high-pressure pump and the water jet could significantly contribute to fatigue crack growth. To determine whether the fatigue crack growth during the leak testing can occur solely by the water jet effect, leak rate tests at constant pressure without the high-pressure pump need to be performed. - Highlights: > Leak rate of flawed Alloy 600 tubing increased at constant pressure condition. > Fractography revealed two cases: ductile tearing and crystallographic facets. > Crystallographic facets are typical features of fatigue crack growth at low {Delta}K. > Fatigue source could be water jet-induced vibration and/or high-pressure pump pulsation.

  18. Remote Mine Detection Technologies for Land and Water Environments

    Energy Technology Data Exchange (ETDEWEB)

    Hoover, Eddie R.

    1999-05-11

    The detection of mines, both during and after hostilities, is a growing international problem. It limits military operations during wartime and unrecovered mines create tragic consequences for civilians. From a purely humanitarian standpoint an estimated 100 million or more unrecovered mines are located in over 60 countries worldwide. This paper presents an overview of some of the technologies currently being investigated by Sandia National Laboratories for the detection and monitoring of minefields in land and water environments. The three technical areas described in this paper are: 1) the development of new mathematical techniques for combining or fusing the data from multiple sources for enhanced decision-making; 2) an environmental fate and transport (EF&T) analysis approach that is central to improving trace chemical sensing technique; and 3) the investigation of an underwater range imaging device to aid in locating and characterizing mines and other obstacles in coastal waters.

  19. Aptasensor development for detection of virus in water

    DEFF Research Database (Denmark)

    Kirkegaard, Julie

    Contamination of water by waterborne viruses causes serious health issues worldwide. The current virus detection methods are expensive and time-consuming and require access to well-equipped laboratories. This thesis describes the development of an impedimetric all-polymer aptasensor for detection...... and finally an impedimetric electrical characterisation of the sensor. The sample preparation of the rotavirus was based on purification and biotinylation of the virus to meet the requirements of the aptamer selection process. The selection process, performed by an external collaborator, was based...... was stable in the measured pH range, which corresponds to the expected pH range of water samples.. The stability of the aptasensor chip was tested over a 2 week period in continuous flow. It was found that the electrodes were not damaged or degraded during the time period, as a constant impedance signal...

  20. Highly sensitive gas leak detector based on a quartz-enhanced photoacoustic SF6 sensor.

    Science.gov (United States)

    Sampaolo, Angelo; Patimisco, Pietro; Giglio, Marilena; Chieco, Leonardo; Scamarcio, Gaetano; Tittel, Frank K; Spagnolo, Vincenzo

    2016-07-11

    The implementation, performance validation, and testing of a gas-leak optical sensor based on mid-IR quartz-enhanced photoacoustic (QEPAS) spectroscopic technique is reported. A QEPAS sensor was integrated in a vacuum-sealed test station for mechatronic components. The laser source for the sensor is a quantum cascade laser emitting at 10.56 µm, resonant with a strong absorption band of sulfur hexafluoride (SF6), which was selected as a leak tracer. The minimum detectable concentration of the QEPAS sensor is 2.7 parts per billion with an integration time of 1 s, corresponding to a sensitivity of leak flows in the 10-9 mbar∙l/s range, comparable with state-of-the-art leak detection techniques.

  1. Detection of Water Hazards for Autonomous Robotic Vehicles

    Science.gov (United States)

    Matthes, Larry; Belluta, Paolo; McHenry, Michael

    2006-01-01

    Four methods of detection of bodies of water are under development as means to enable autonomous robotic ground vehicles to avoid water hazards when traversing off-road terrain. The methods involve processing of digitized outputs of optoelectronic sensors aboard the vehicles. It is planned to implement these methods in hardware and software that would operate in conjunction with the hardware and software for navigation and for avoidance of solid terrain obstacles and hazards. The first method, intended for use during the day, is based on the observation that, under most off-road conditions, reflections of sky from water are easily discriminated from the adjacent terrain by their color and brightness, regardless of the weather and of the state of surface waves on the water. Accordingly, this method involves collection of color imagery by a video camera and processing of the image data by an algorithm that classifies each pixel as soil, water, or vegetation according to its color and brightness values (see figure). Among the issues that arise is the fact that in the presence of reflections of objects on the opposite shore, it is difficult to distinguish water by color and brightness alone. Another issue is that once a body of water has been identified by means of color and brightness, its boundary must be mapped for use in navigation. Techniques for addressing these issues are under investigation. The second method, which is not limited by time of day, is based on the observation that ladar returns from bodies of water are usually too weak to be detected. In this method, ladar scans of the terrain are analyzed for returns and the absence thereof. In appropriate regions, the presence of water can be inferred from the absence of returns. Under some conditions in which reflections from the bottom are detectable, ladar returns could, in principle, be used to determine depth. The third method involves the recognition of bodies of water as dark areas in short

  2. In-Situ Detection of Contaminant Plumes in Ground Water

    Science.gov (United States)

    1990-08-01

    of Engineers Cold Regions Research & Engineering Laboratory In-Situ Detection of Contaminant Plumes in Ground Water W. Rudott Setz August 1990 U S APMY...immunochemnical methodis for system (Inmanect al. 1989). Another attractiv : approach tetryl. benizene. dieldrin and paria-chloroptienylm.-th- is to us. a...not been any further work on cyanide. censt complexes. Of the important metal mo conuamni- The Office of Naval Research has recently made the nairts

  3. Analytical methodologies for the detection of sucralose in water.

    Science.gov (United States)

    Ferrer, Imma; Zweigenbaum, Jerry A; Thurman, E Michael

    2013-10-15

    A detailed evaluation of two liquid chromatography-mass spectrometry techniques, quadrupole time-of-flight mass spectrometry (LC/Q-TOF-MS) and triple quadrupole mass spectrometry (LC/MS-MS), was carried out in terms of sensitivity, selectivity, and ionization mode for the detection of sucralose in environmental water samples, which is an important environmental topic in water analysis. Interesting findings were made in regards to fragmentation and sensitivity when both techniques and both ionization modes of operation were compared. In positive ion mode, sucralose was detected by its sodium adduct [M + Na](+) at m/z 419.0038. Fragmentation by MS-MS of the sodiated molecule was possible using either LC/MS-MS or LC/Q-TOF-MS under positive ionization. Accurate mass measurements provided exact structural confirmation of the sodiated fragments obtained (m/z 221.0187 and m/z 238.9848). In negative ion mode, the deprotonated molecule was observed ([M - H](-) at m/z 395.0073), and fragmentation by MS-MS yielded two characteristic fragment ions (m/z 359.0306 and m/z 34.9694). Because sucralose contains three chlorine atoms, time-of-flight analyses provided a valuable amount of isotopic accurate mass information for its detection. With LC/MS-MS, the sensitivity was 10 times higher in positive ion mode than in negative ion mode, with limits of detection of 15 ng/L. Similarly, when time-of-flight mass spectrometry was used, the sensitivity was slightly better in positive ion mode, with limits of detection of 400 ng/L. Matrix effects were observed for surface and wastewater samples; thus the use of a deuterated standard (sucralose-d6) was crucial for precise quantitation. The most sensitive analytical methodology for the analysis of sucralose in water samples was LC/MS-MS using triple quadrupole under positive ion mode.

  4. Water stress detection in the Amazon using radar

    Science.gov (United States)

    van Emmerik, Tim; Steele-Dunne, Susan; Paget, Aaron; Oliveira, Rafael S.; Bittencourt, Paulo R. L.; Barros, Fernanda de V.; van de Giesen, Nick

    2017-07-01

    The Amazon rainforest plays an important role in the global water and carbon cycle, and though it is predicted to continue drying in the future, the effect of drought remains uncertain. Developments in remote sensing missions now facilitate large-scale observations. The RapidScat scatterometer (Ku band) mounted on the International Space Station observes the Earth in a non-Sun-synchronous orbit, which allows for studying changes in the diurnal cycle of radar backscatter over the Amazon. Diurnal cycles in backscatter are significantly affected by the state of the canopy, especially during periods of increased water stress. We use RapidScat backscatter time series and water deficit measurements from dendrometers in 20 trees during a 9 month period to relate variations in backscatter to increased tree water deficit. Morning radar bacskcatter dropped significantly with increased tree water deficit measured with dendrometers. This provides unique observational evidence that demonstrates the sensitivity of radar backscatter to vegetation water stress, highlighting the potential of drought detection and monitoring using radar.

  5. Successful Endoscopic Therapy of Traumatic Bile Leaks

    Directory of Open Access Journals (Sweden)

    Matthew P. Spinn

    2013-02-01

    Full Text Available Traumatic bile leaks often result in high morbidity and prolonged hospital stay that requires multimodality management. Data on endoscopic management of traumatic bile leaks are scarce. Our study objective was to evaluate the efficacy of the endoscopic management of a traumatic bile leak. We performed a retrospective case review of patients who were referred for endoscopic retrograde cholangiopancreatography (ERCP after traumatic bile duct injury secondary to blunt (motor vehicle accident or penetrating (gunshot trauma for management of bile leaks at our tertiary academic referral center. Fourteen patients underwent ERCP for the management of a traumatic bile leak over a 5-year period. The etiology included blunt trauma from motor vehicle accident in 8 patients, motorcycle accident in 3 patients and penetrating injury from a gunshot wound in 3 patients. Liver injuries were grade III in 1 patient, grade IV in 10 patients, and grade V in 3 patients. All patients were treated by biliary stent placement, and the outcome was successful in 14 of 14 cases (100%. The mean duration of follow-up was 85.6 days (range 54-175 days. There were no ERCP-related complications. In our case review, endoscopic management with endobiliary stent placement was found to be successful and resulted in resolution of the bile leak in all 14 patients. Based on our study results, ERCP should be considered as first-line therapy in the management of traumatic bile leaks.

  6. Water-soaked evidence: detectability of explosive traces after immersion in water.

    Science.gov (United States)

    Kamyshny, Alexander; Magdassi, Shlomo; Avissar, Yaniv; Almog, Joseph

    2003-03-01

    Various factors governing the detectability of explosive traces after being soaked in water were studied. The variables are: the type of the surface (surfaces liable to be found in aircraft were chosen), the type of explosive, the type of water (tap or seawater), and movement of the immersed surface in the water. The maximal immersion times (tmax) after which explosive detection was possible were evaluated. This datum was found to depend on the type of explosive (one of the important factors is solubility in water), the surface material and the environmental conditions (tap or seawater movement). Detection of PETN on high-density polyethylene, linoleum, glass and aluminum, by the chemical Explosive Testing Kit (ETK), was possible even after a month of soaking in seawater. In addition, it has been found that movement of bulk water around the samples with deposited explosives considerably decreases tmax values. It is, therefore, recommended to retrieve samples for explosive analysis as soon as possible and in areas where the currents of water is minimal.

  7. Detection of Ground Water Availability at Buhias Island, Sitaro Regency

    Directory of Open Access Journals (Sweden)

    Zetly E Tamod

    2016-08-01

    Full Text Available The study aims to detect ground water availability at Buhias Island, Siau Timur Selatan District, Sitaro Regency. The research method used the survey method by geoelectrical instrument based on subsurface rock resistivity as a geophysical exploration results with geoelectrical method of Wenner-Schlumberger configuration. Resistivity geoelectrical method is done by injecting a flow into the earth surface, then it is measured the potential difference. This study consists of 4 tracks in which each track is made the stretch model of soil layer on subsurface of ground.  Then, the exploration results were processed using software RES2DINV to look at the data of soil layer based on the value of resistivity (2D. Interpretation result of the track 1 to 4 concluded that there is a layer of ground water. State of dominant ground water contains the saline (brackish. Location of trajectory in the basin to the lowland areas is mostly mangrove swamp vegetation. That location is the junction between the results of the runoff of rainfall water that falls down from the hills with sea water. Bedrock as a constituent of rock layer formed from marine sediments that carry minerals salts.

  8. Management of Leaks in Hydrogen Production, Delivery, and Storage Systems

    Energy Technology Data Exchange (ETDEWEB)

    Rawls, G

    2006-04-27

    A systematic approach to manage hydrogen leakage from components is presented. Methods to evaluate the quantity of hydrogen leakage and permeation from a system are provided by calculation and testing sensitivities. The following technology components of a leak management program are described: (1) Methods to evaluate hydrogen gas loss through leaks; (2) Methods to calculate opening areas of crack like defects; (3) Permeation of hydrogen through metallic piping; (4) Code requirements for acceptable flammability limits; (5) Methods to detect flammable gas; (6) Requirements for adequate ventilation in the vicinity of the hydrogen system; (7) Methods to calculate dilution air requirements for flammable gas mixtures; and (8) Concepts for reduced leakage component selection and permeation barriers.

  9. Leaking Underground Storage Tank (LUST) Trust Fund

    Science.gov (United States)

    In 1986, Congress created the Leaking Underground Storage Tank (LUST) Trust Fund to address releases from federally regulated underground storage tanks (USTs) by amending Subtitle I of the Solid Waste Disposal Act.

  10. Express Detection of Pentachlorophenol as Dioxins Precursor in Natural Water

    Directory of Open Access Journals (Sweden)

    Vitalia S. Krikounova

    2002-01-01

    Full Text Available A rapid detection method for the pesticide pentachlorophenol (PCP — polarization fluoroimmunoassay (PFIA — in the dynamic range of 10–9,000 ppb was developed. PCP may form polychlorinated dibenzo-p-dioxins, making environmental monitoring of this compound an issue of great importance. In order to optimize the PFIA procedure, a number of fluorescein-labeled PCP derivatives and similar compounds (tracers were synthesized, and the influence of their structure on PFIA characteristics was studied. Also, two antisera were tested in developing PFIA for PCP. The developed method is highly specific for PCP and can be used for its determination in water samples at a level down to 10 ppb. Total time of the assay for 10 samples is about 7 min. The assay provides a useful and a highly practical screening tool for the processing of large numbers of samples and for the preliminary estimation of potential dioxins contamination in water resources.

  11. Detection of Oil in Water Column, Final Report: Detection Prototype Tests

    Science.gov (United States)

    2014-07-01

    however, PSDs seemed to shift to larger droplets over time, which may be an indication of droplet coalescence over time and/or droplets scavenging... droplet size and density of the entrained oil. Both systems demonstrated the qualitative ability to detect and/or map oil suspended in the water...the oil plume, however, was not possible due to difficulties with correlating and validating the submerged plumes’ specific droplet size and

  12. Noncontact, reagentless, nondestructive, detection of organics, biosignatures, and water

    Science.gov (United States)

    Bhartia, R.; Hug, William F.; Reid, Ray; Salas, Everett C.

    2012-06-01

    We present a new active, non-invasive, non-desctructive, in situ spectroscopic method that enable a better understanding of the spatial distribution of microbes, organics, and water on natural surfaces that could support life-detection, organic stability assessment, and in-situ resource utilization missions on planetary bodies. Analytical and spectroscopic methods that have been employed to attempt to address these types of questions provide detection over a limited spatial area, provide either significant false positives/false negatives, or are limited to either morphological or chemical information. Furthermore, apart from the spectroscopic analyses, the methods are limited to invasive treatments that alter the samples or remove critical spatial context. Active spectroscopic methods such Raman and or LIBS have been employed as a means to approach these questions however, traditional Raman scatting is an extremely weak phenomenon and LIBS provides looses information regarding chemical structure. As an alternative, we present the use of deep UV native fluorescence, Raman spectroscopy and hyperspectral imaging from proximity (1-10 cm) to standoff (1-5m). Deep UV native fluorescence, coupled to resonance Raman spectroscopy, can provide a solution that has a means to map large areas with sensitivities to organics, that are expected to be present from meteoritic infall, biosignatures indicating extant or extinct life, and detect the presence of water for in-situ resource utilization. The methodology and the data presented will demonstrate the ability to detect and differentiate organics a natural surface - relevant to Mars and other planetary surfaces, and also elucidate the distribution to enable an understanding of their provenance.

  13. VISUAL INSPECTION OF WATER LEAKAGE FROM GROUND PENETRATING RADAR RADARGRAM

    Directory of Open Access Journals (Sweden)

    N. N. Halimshah

    2015-10-01

    Full Text Available Water loss in town and suburban is currently a significant issue which reflect the performance of water supply management in Malaysia. Consequently, water supply distribution system has to be maintained in order to prevent shortage of water supply in an area. Various techniques for detecting a mains water leaks are available but mostly are time-consuming, disruptive and expensive. In this paper, the potential of Ground Penetrating Radar (GPR as a non-destructive method to correctly and efficiently detect mains water leaks has been examined. Several experiments were designed and conducted to prove that GPR can be used as tool for water leakage detection. These include instrument validation test and soil compaction test to clarify the maximum dry density (MDD of soil and simulation studies on water leakage at a test bed consisting of PVC pipe burying in sand to a depth of 40 cm. Data from GPR detection are processed using the Reflex 2D software. Identification of water leakage was visually inspected from the anomalies in the radargram based on GPR reflection coefficients. The results have ascertained the capability and effectiveness of the GPR in detecting water leakage which could help avoiding difficulties with other leak detection methods.

  14. Technique for rapid detection of phthalates in water and beverages

    KAUST Repository

    Zia, Asif I.

    2013-05-01

    The teratogenic and carcinogenic effects of phthalate esters on living beings are proven in toxicology studies. These ubiquitous food and environmental pollutants pose a great danger to the human race due to their extraordinary use as a plasticizer in the consumer product industry. Contemporary detection techniques used for phthalates require a high level of skills, expensive equipment and longer analysis time than the presented technique. Presented research work introduces a real time non-invasive detection technique using a new type of silicon substrate based planar interdigital (ID) sensor fabricated on basis of thin film micro-electromechanical system (MEMS) semiconductor device fabrication technology. Electrochemical impedance spectroscopy (EIS) was used in conjunction with the fabricated sensor to detect phthalates in deionized water. Various concentrations of di(2-ethylhexyl) phthalate (DEHP) as low as 2 ppb to a higher level of 2 ppm in deionized water were detected distinctively using new planar ID sensor based EIS sensing system. Dip testing method was used to obtain the conductance and dielectric properties of the bulk samples. Parylene C polymer coating was used as a passivation layer on the surface of the fabricated sensor to reduce the influence of Faradaic currents. In addition, inherent dielectric properties of the coating enhanced the sensitivity of the capacitive type sensor. Electrochemical spectrum analysis algorithm was used to model experimentally observed impedance spectrum to deduce constant phase element (CPE) equivalent circuit to analyse the kinetic processes taking place inside the electrochemical cell. Curve fitting technique was used to extract the values of the circuit components and explain experimental results on theoretical grounds. The sensor performance was tested by adding DEHP to an energy drink at concentrations above and below the minimal risk level (MRL) limit set by the ATSDR (Agency for Toxic Substances & Disease Registry

  15. Annular Air Leaks in a liquid hydrogen storage tank

    Science.gov (United States)

    Krenn, AG; Youngquist, RC; Starr, SO

    2017-12-01

    Large liquid hydrogen (LH2) storage tanks are vital infrastructure for NASA, the DOD, and industrial users. Over time, air may leak into the evacuated, perlite filled annular region of these tanks. Once inside, the extremely low temperatures will cause most of the air to freeze. If a significant mass of air is allowed to accumulate, severe damage can result from nominal draining operations. Collection of liquid air on the outer shell may chill it below its ductility range, resulting in fracture. Testing and analysis to quantify the thermal conductivity of perlite that has nitrogen frozen into its interstitial spaces and to determine the void fraction of frozen nitrogen within a perlite/frozen nitrogen mixture is presented. General equations to evaluate methods for removing frozen air, while avoiding fracture, are developed. A hypothetical leak is imposed on an existing tank geometry and a full analysis of that leak is detailed. This analysis includes a thermal model of the tank and a time-to-failure calculation. Approaches to safely remove the frozen air are analyzed, leading to the conclusion that the most feasible approach is to allow the frozen air to melt and to use a water stream to prevent the outer shell from chilling.

  16. Hybrid Intelligent Warning System for Boiler tube Leak Trips

    Directory of Open Access Journals (Sweden)

    Singh Deshvin

    2017-01-01

    Full Text Available Repeated boiler tube leak trips in coal fired power plants can increase operating cost significantly. An early detection and diagnosis of boiler trips is essential for continuous safe operations in the plant. In this study two artificial intelligent monitoring systems specialized in boiler tube leak trips have been proposed. The first intelligent warning system (IWS-1 represents the use of pure artificial neural network system whereas the second intelligent warning system (IWS-2 represents merging of genetic algorithms and artificial neural networks as a hybrid intelligent system. The Extreme Learning Machine (ELM methodology was also adopted in IWS-1 and compared with traditional training algorithms. Genetic algorithm (GA was adopted in IWS-2 to optimize the ANN topology and the boiler parameters. An integrated data preparation framework was established for 3 real cases of boiler tube leak trip based on a thermal power plant in Malaysia. Both the IWSs were developed using MATLAB coding for training and validation. The hybrid IWS-2 performed better than IWS-1.The developed system was validated to be able to predict trips before the plant monitoring system. The proposed artificial intelligent system could be adopted as a reliable monitoring system of the thermal power plant boilers.

  17. Leaking Photons from the HII Region NGC 7538

    Science.gov (United States)

    Luisi, Matteo; Anderson, Loren D.; Balser, Dana S.; Bania, Thomas M.; Wenger, Trey

    2016-01-01

    Using data from the NRAO Green Bank Telescope and the INT Photometric H-Alpha Survey of the Northern Galactic Plane (IPHAS), we analyze the ionizing radiation that is escaping the photo-dissociation region (PDR) boundary of the HII region NGC 7538. We find extended radio continuum and radio recombination line (RRL) emission outside the PDR toward the north and east of the region. This suggests that a non-uniform PDR morphology is affecting the amount of radiation "leaking" through the PDR. We quantify the leaking photon fraction along the line of sight, and use a numerical model to estimate the leaking photon fraction in three dimensions of both radio continuum and H-alpha emission. We detect carbon RRL emission near the PDR and find a decrease in the helium-to-hydrogen ionic abundance ratio with increasing distance from the central position. This indicates a softening of the radiation field within the PDR. Using Herschel Space Observatory data, we create a dust temperature map of the region and show that small dust temperature enhancements to the north and east of NGC 7538 coincide with extended radio emission. We discuss implications for maintaining the ionization of the warm interstellar medium by HII regions.

  18. Evaluation of methodologies for the calculation of leak rates for pressure retaining components with crack-like leaks; Bewertung von Methoden zur Berechnung von Leckraten fuer druckfuehrende Komponenten mit rissartigen Lecks

    Energy Technology Data Exchange (ETDEWEB)

    Sievers, Juergen; Heckmann, Klaus; Blaesius, Christoph

    2015-06-15

    For the demonstration of break preclusion for pressure retaining components in nuclear power plants, the nuclear safety standard KTA 3206 determines also the requirements for the leak-before-break verification. For this procedure, it has to be ensured that a wall-penetrating crack is subcritical with respect to instable growth, and that the resulting leakage under stationary operation conditions can be detected by a leak detection system. Within the scope of the project 3613R01332 analyses with respect to conservative estimates of the leak rates in case of detections regarding break preclusion were performed by means of leak rate models being available at GRS. For this purpose, conservative assumptions in the procedure were quantified by comparative calculations concerning selected leak rate experiments and the requirements regarding the determination of leak rates indicated in the KTA 3206 were verified and specified. Moreover, the models were extended and relevant recommendations for the calculation procedure were developed. During the investigations of leak rate tests the calculation methods were validated, qualified by means of both examples indicated in KTA 3206 and applied to a postulated leak accident in the cooling circuit of a PWR. For the calculation of leak rates several simplified solution methods which are included in the GRS program WinLeck were applied, and for the simulation of a leak accident the large-scale programs ANSYS Mechanical and ATHLET (thermohydraulics program developed by GRS) were used. When applying simplified methods for the calculation of leak rates using the limiting curve for the friction factor which has been derived during the project and which is included in the KTA 3206 attention has to be paid to the fact that in case of small flow lengths the entrance loss can dominate compared to the friction loss. However, the available data do not suffice in order to make a quantitative statement with respect to limits of applicability

  19. Fluorescence Sensors for Early Detection of Nitrification in Drinking Water Distribution Systems – Interference Corrections (Poster)

    Science.gov (United States)

    Nitrification event detection in chloraminated drinking water distribution systems (DWDSs) remains an ongoing challenge for many drinking water utilities, including Dallas Water Utilities (DWU) and the City of Houston (CoH). Each year, these utilities experience nitrification eve...

  20. Fluorescence Sensors for Early Detection of Nitrification in Drinking Water Distribution Systems – Interference Corrections (Abstract)

    Science.gov (United States)

    Nitrification event detection in chloraminated drinking water distribution systems (DWDSs) remains an ongoing challenge for many drinking water utilities, including Dallas Water Utilities (DWU) and the City of Houston (CoH). Each year, these utilities experience nitrification eve...

  1. Driver detection of water quality trends across Mediterranean river basins

    Science.gov (United States)

    Diamantini, Elena; Lutz, Stefanie; Mallucci, Stefano; Majone, Bruno; Merz, Ralf; Bellin, Alberto

    2017-04-01

    In this study, thirteen physicochemical surficial water variables and four drivers (i.e. monthly aggregated air temperature and streamflow, population density and percentage of agricultural land use) were analysed in three large Mediterranean river basins (i.e. Adige, Ebro, Sava). In particular, the purpose of the analysis is to identify how indicators of water quality and drivers of change coevolve in three large river basins representing the diversity of climatic, soil and water uses conditions observed in southern Europe. Spearman rank correlation, principal component analysis, Mann-Kendall trend test and Sen's Slope estimator were performed in order to (i) analyse long-term time series of water quality data during the period 1990-2015, (ii) detect links between variables patterns and drivers and (iii) compare the river basins under investigation with respect to their vulnerability and resilience to the identified drivers of change. Results show that air temperature, considered as a proxy of climate change, has a significant impact in all basins but in particular in the Adige and Ebro: positive trends of water temperature and negative for dissolved oxygen are found to be correlated with upward trends of air temperatures. The aquatic ecosystems of these rivers are therefore experiencing a reduction in oxygen, which may further worsen in the future given the projected increase of temperature for this century. At the same time, monthly streamflow has been shown to reduce in the Ebro River, thereby decreasing the beneficial effect of dilution, as appears evident from the observed upward patterns of chloride concentration and electrical conductivity. Upward trends of chloride and biological oxygen demand in the Adige and Sava and positive trends of phosphate in the Adige are related to the increase of population and finally phosphates in the Sava and biological oxygen demand in the Ebro are highly correlated with agricultural land use. The study showed the complex

  2. Crack growth of throughwall flaw in Alloy 600 tube during leak testing

    Energy Technology Data Exchange (ETDEWEB)

    Bahn, Chi Bum, E-mail: bahn@pusan.ac.kr [Pusan National University, 2 Busandaehak-ro 63beon-gil, Geumjeong-gu, Busan 609-735 (Korea, Republic of); Majumdar, Saurin [Argonne National Laboratory, Lemont, IL 60439 (United States)

    2015-04-01

    Graphical abstract: - Highlights: • A series of leak testing was conducted at a constant pressure and room temperature. • The time-dependent increase in the leak rate was observed. • The fractography revealed slip offsets and crystallographic facets. • Time-dependent plasticity at the crack tip caused the slip offsets. • Fatigue by jet/structure interaction caused the crystallographic facets. - Abstract: We examined the issue of whether crack growth in a full thickness material can occur in a leaking crack. A series of leak tests was conducted at a room temperature and constant pressure (17.3 MPa) with Alloy 600 tube specimens containing a tight rectangular throughwall axial fatigue crack. To exclude a potential pulsation effect by a high pressure pump, the test water was pressurized by using high pressure nitrogen gas. Fractography showed that crack growth in the full thickness material can occur in the leaking crack by two mechanisms: time-dependent plasticity at the crack tip and fatigue induced by jet/structure interaction. The threshold leak rate at which the jet/structure interaction was triggered was between 1.3 and 3.3 L/min for the specific heat of the Alloy 600 tube tested.

  3. Airway obstruction and gas leak during mask ventilation of preterm infants in the delivery room.

    Science.gov (United States)

    Schmölzer, Georg M; Dawson, Jennifer A; Kamlin, C Omar F; O'Donnell, Colm P F; Morley, Colin J; Davis, Peter G

    2011-07-01

    Preterm infants with inadequate breathing receive positive pressure ventilation (PPV) by mask with variable success. The authors examined recordings of PPV given to preterm infants in the delivery room for prevalence of mask leak and airway obstruction. The authors reviewed recordings of infants at piece or self-inflating bag and a round silicone face mask. Airway pressures and gas flow were recorded with a respiratory function monitor (RFM). Videos recorded from a web camera were used to review the resuscitation. The first 2 min of PPV were analysed for each infant. Obstruction was arbitrarily defined as a 75% reduction in delivered expired tidal volume (V(Te)) and significant face-mask leak as >75%. The authors analysed recordings of 56 preterm infants. Obstruction occurred in 14 (26%) recordings and leaks in 27 (51%). Both obstruction and mask leaks were seen in eight (14%) recordings, and neither was seen in 15 (27%). Obstruction occurred at a median (IQR) of 48 (24-60) s after the start of PPV. A median (range) of 22 (3-83) consecutive obstructed inflations were delivered. Face-mask leaks occurred from the first inflation in 19/27 (70%) and in the remaining eight at a median (IQR) of 30 (24-46) s after the start of PPV. A median (range) of 10 (3-117) consecutive inflations with a leak >75% were delivered. Airway obstruction and face-mask leak are common during the first 2 min of PPV. An RFM enables detection of important airway obstruction and mask leak.

  4. Endoscopic Management of Gastrointestinal Leaks and Fistulae.

    Science.gov (United States)

    Willingham, Field F; Buscaglia, Jonathan M

    2015-10-01

    Gastrointestinal leaks and fistulae can be serious acute complications or chronic morbid conditions resulting from inflammatory, malignant, or postsurgical states. Endoscopic closure of gastrointestinal leaks and fistulae represents major progress in the treatment of patients with these complex presentations. The main goal of endoscopic therapy is the interruption of the flow of luminal contents across a gastrointestinal defect. In consideration of the proper endoscopic approach to luminal closure, several basic principles must be considered. Undrained cavities and fluid collections must often first be drained percutaneously, and the percutaneous drain provides an important measure of safety for subsequent endoscopic luminal manipulations. The size and exact location of the leak/fistula, as well as the viability of the surrounding tissue, must be defined. Almost all complex leaks and fistulae must be approached in a multidisciplinary manner, collaborating with colleagues in nutrition, radiology, and surgery. Currently, gastrointestinal leaks and fistulae may be managed endoscopically by using 1 or more of the following modalities: stent placement, clip closure (including through-the-scope clips and over-the-scope devices), endoscopic suturing, and the injection of tissue sealants. In this article, we discuss these modalities and review the published outcomes data regarding each approach as well as practical considerations for successful closure of luminal defects. Copyright © 2015 AGA Institute. Published by Elsevier Inc. All rights reserved.

  5. Detecting pin diversion from pressurized water reactors spent fuel assemblies

    Energy Technology Data Exchange (ETDEWEB)

    Ham, Young S.; Sitaraman, Shivakumar

    2017-01-10

    Detecting diversion of spent fuel from Pressurized Water Reactors (PWR) by determining possible diversion including the steps of providing a detector cluster containing gamma ray and neutron detectors, inserting the detector cluster containing the gamma ray and neutron detectors into the spent fuel assembly through the guide tube holes in the spent fuel assembly, measuring gamma ray and neutron radiation responses of the gamma ray and neutron detectors in the guide tube holes, processing the gamma ray and neutron radiation responses at the guide tube locations by normalizing them to the maximum value among each set of responses and taking the ratio of the gamma ray and neutron responses at the guide tube locations and normalizing the ratios to the maximum value among them and producing three signatures, gamma, neutron, and gamma-neutron ratio, based on these normalized values, and producing an output that consists of these signatures that can indicate possible diversion of the pins from the spent fuel assembly.

  6. A detection of the coarse water droplets in steam turbines

    Directory of Open Access Journals (Sweden)

    Bartoš Ondřej

    2014-03-01

    Full Text Available The aim of this paper is to introduce a novel method for the detection of coarse water droplets in a low pressure part of steam turbines. The photogrammetry method has been applied for the measurement of coarse droplets in the low-pressure part of a steam turbine. A new probe based on this measurement technique was developed and tested in the laboratory and in a steam turbine in the Počerady power-plant. The probe was equipped with state-of-the-art instrumentation. The paper contains results from laboratory tests and the first preliminary measurements in a steam turbine. Possible applications of this method have been examined.

  7. Robust Meter Network for Water Distribution Pipe Burst Detection

    Directory of Open Access Journals (Sweden)

    Donghwi Jung

    2017-10-01

    Full Text Available A meter network is a set of meters installed throughout a water distribution system to measure system variables, such as the pipe flow rate and pressure. In the current hyper-connected world, meter networks are being exposed to meter failure conditions, such as malfunction of the meter’s physical system and communication system failure. Therefore, a meter network’s robustness should be secured for reliable provision of informative meter data. This paper introduces a multi-objective optimal meter placement model that maximizes the detection probability, minimizes false alarms, and maximizes the robustness of a meter network given a predefined number of meters. A meter network’s robustness is defined as its ability to consistently provide quality data in the event of meter failure. Based on a single-meter failure simulation, a robustness indicator for the meter network is introduced and maximized as the third objective of the proposed model. The proposed model was applied to the Austin network to determine the independent placement of pipe flow and pressure meters with three or five available meters. The results showed that the proposed model is a useful tool for determining meter locations to secure high detectability and robustness.

  8. Electrochemical Sensor for Explosives Precursors’ Detection in Water

    Directory of Open Access Journals (Sweden)

    Cloé Desmet

    2017-03-01

    Full Text Available Although all countries are intensifying their efforts against terrorism and increasing their mutual cooperation, terrorist bombing is still one of the greatest threats to society. The discovery of hidden bomb factories is of primary importance in the prevention of terrorism activities. Criminals preparing improvised explosives (IE use chemical substances called precursors. These compounds are released in the air and in the waste water during IE production. Tracking sources of precursors by analyzing air or wastewater can then be an important clue for bomb factories’ localization. We are reporting here a new multiplex electrochemical sensor dedicated to the on-site simultaneous detection of three explosive precursors, potentially used for improvised explosive device preparation (hereafter referenced as B01, B08, and B15, for security disclosure reasons and to avoid being detrimental to the security of the counter-explosive EU action. The electrochemical sensors were designed to be disposable and to combine ease of use and portability in a screen-printed eight-electrochemical cell array format. The working electrodes were modified with different electrodeposited metals: gold, palladium, and platinum. These different coatings giving selectivity to the multi-sensor through a “fingerprint”-like signal subsequently analyzed using partial least squares-discriminant analysis (PLS-DA. Results are given regarding the detection of the three compounds in a real environment and in the presence of potentially interfering species.

  9. Standard practice for atmospheric leaks using a thermal conductivity leak detector

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2011-01-01

    1.1 This practice covers procedures for detecting the sources of gas leaking at the rate of 1 × 10–5 Pa m3/s (1 × 10–4 standard cm3/s) or greater. The tests may be conducted on any object that can be pressurized with a tracer gas that is detectable by a thermal conductivity detector. The test sensitivity will vary widely depending on the tracer gas used. 1.2 Units—The values stated in either SI or std-cc/sec units are to be regarded separately as standard. The values stated in each system may not be exact equivalents: therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  10. CT assessment of anastomotic bowel leak

    Energy Technology Data Exchange (ETDEWEB)

    Power, N. [Department of Radiology, Sunnybrook Hospital, Toronto, Ontario M4N 3M5 (Canada); Atri, M. [Department of Radiology, Sunnybrook Hospital, Toronto, Ontario M4N 3M5 (Canada)]. E-mail: mostafa.atri@sw.ca; Ryan, S. [Department of Radiology, Sunnybrook Hospital, Toronto, Ontario M4N 3M5 (Canada); Haddad, R. [Department of Surgery, Sunnybrook Hospital, Toronto, Ontario M4N 3M5 (Canada); Smith, A. [Department of Surgery, Sunnybrook Hospital, Toronto, Ontario M4N 3M5 (Canada)

    2007-01-15

    Aim: To evaluate the predictors of clinically important gastrointestinal anastomotic leaks using multidetector computed tomography (CT). Subjects and methods: Ninety-nine patients, 73 with clinical suspicion of anastomotic bowel leak and 26 non-bowel surgery controls underwent CT to investigate postoperative sepsis. Fifty patients had undergone large bowel and 23 small bowel anastomoses. The time interval from surgery was 3-30 days (mean 10 {+-} 5.9 SD) for the anastomotic group and 3-40 days (mean 14 {+-} 11 SD) for the control group (p = 0.3). Two radiologists blinded to the final results reviewed the CT examinations in consensus and recorded the presence of peri-anastomotic air, fluid or combination of the two; distant loculated fluid or combination of fluid and air; free air or fluid; and intestinal contrast leak. Final diagnosis of clinically important anastomotic leak (CIAL) was confirmed at surgery or by chart review of predetermined clinical and laboratory criteria. Results: The prevalence of CIAL in the group undergoing CT was 31.5% (23/73). The CT examinations with documented leak were performed 5-28 (mean; 11.4 {+-} 6 SD) days after surgery. Nine patients required repeat operation, 10 percutaneous abscess drainage, two percutaneous drainage followed by surgery, and two prolonged antibiotic treatment and total parenteral nutrition (TPN). Of the CT features examined, only peri-anastomotic loculated fluid containing air was more frequently seen in the CIAL group as opposed to the no leak group (p = 0.04). There was no intestinal contrast leakage in this cohort. Free air was present up to 9 days and loculated air up to 26 days without CIAL. Conclusion: Most postoperative CT features overlap between patients with and without CIAL. The only feature seen statistically more frequently with CIAL is peri-anastomotic loculated fluid containing air.

  11. CT assessment of anastomotic bowel leak.

    Science.gov (United States)

    Power, N; Atri, M; Ryan, S; Haddad, R; Smith, A

    2007-01-01

    To evaluate the predictors of clinically important gastrointestinal anastomotic leaks using multidetector computed tomography (CT). Ninety-nine patients, 73 with clinical suspicion of anastomotic bowel leak and 26 non-bowel surgery controls underwent CT to investigate postoperative sepsis. Fifty patients had undergone large bowel and 23 small bowel anastomoses. The time interval from surgery was 3-30 days (mean 10+/-5.9 SD) for the anastomotic group and 3-40 days (mean 14+/-11 SD) for the control group (p=0.3). Two radiologists blinded to the final results reviewed the CT examinations in consensus and recorded the presence of peri-anastomotic air, fluid or combination of the two; distant loculated fluid or combination of fluid and air; free air or fluid; and intestinal contrast leak. Final diagnosis of clinically important anastomotic leak (CIAL) was confirmed at surgery or by chart review of predetermined clinical and laboratory criteria. The prevalence of CIAL in the group undergoing CT was 31.5% (23/73). The CT examinations with documented leak were performed 5-28 (mean; 11.4+/-6 SD) days after surgery. Nine patients required repeat operation, 10 percutaneous abscess drainage, two percutaneous drainage followed by surgery, and two prolonged antibiotic treatment and total parenteral nutrition (TPN). Of the CT features examined, only peri-anastomotic loculated fluid containing air was more frequently seen in the CIAL group as opposed to the no leak group (p=0.04). There was no intestinal contrast leakage in this cohort. Free air was present up to 9 days and loculated air up to 26 days without CIAL. Most postoperative CT features overlap between patients with and without CIAL. The only feature seen statistically more frequently with CIAL is peri-anastomotic loculated fluid containing air.

  12. Factors affecting bond cement across casing leak zones in oil and gas wells

    Energy Technology Data Exchange (ETDEWEB)

    Nasr, Mohamed; Edbeib, Said [Al-Fateh University, Tripoli (Libyan Arab Jamahiriya). Dept. of Petroleum Engineering

    2004-07-01

    Casing leaks have been a major concern to the oil industry because of their effect on lowering the production rate in many oil and gas wells. The leaks are the result of deterioration of the casing in the well, which is caused by severe corrosion due to the contact of the casing with high salinity foreign fluid. The objective of this study is to determine the factors influencing the mechanical properties of the hardened cement opposite the casing leak zones. This study is conducted by laboratory measurements of the compressive strength of the hardened cement when the cement slurry was mixed with different percentages of formation water and different concentrations of different cement additives. The results of this study indicate that the compressive strength readings obtained from the cement bond log and the cement evaluation tool against the casing leak zones are lower than those readings recorded in adjacent formations. The low cement compressive strength values observed across casing leak zones are due to the contamination of the cement with saline water present in these formations which, in turn, effects the hardening properties of the cement. The experimental results indicated that the salinity of the formation water when mixed with the cement slurry in the presence of cement additives, decreased the compressive strength of the bond cement and also decreased the thickening time of the cement slurry. It is concluded that casing leaks found in many wells observed in oil fields in Libya were due to the mixing of the cement with high salinity formation water present in the lost circulation zones. The high water salinity in these zones effects the setting time of the cement slurry which, therefore, decreased the hardening properties of the bond cement and caused cracks and channels in the hardened cement across lost circulation zones. (author)

  13. Analysis of Pressure Data As CO2/Brine Leak Diagnostic in Shallow Aquifers

    Science.gov (United States)

    Trainor Guitton, W.; Mansoor, K.; Sun, Y.; Carroll, S.

    2014-12-01

    Pressure is a promising signal for detecting CO2leakage from deep, geologic storage reservoirs to shallow groundwater sources. Pressure signals should faster than other physical indications (i.e. electrical or geochemical changes) thus allowing for a timely leak diagnosis and mitigation. We explore the effectiveness of pressure as a detection tool. A simulation-based approach is used to diagnose a CO2/brine leak using pressure data from monitoring wells and to assess the influence of 3 principal uncertainties: distances between the source leak and the monitoring well, heterogeneity of the aquifer flow properties, and CO2 and brine leakage rates. Specifically, five parameters are sampled: the correlation lengths of the vertical and horizontal permeability for the aquifer (2), the sand proportion for each model (1), and the CO2 and brine leakage flux magnitude (2). Areal model dimensions and grid cell dimensions allow for sampling distances of 25 m to 990 m from the leaking well to the monitoring well. We generate 500 simulations by sampling each parameter within an appropriate range predefined by site-specific values. Pressure transducers in monitoring wells will only be accurate at measuring changes on the order of 0.1 to 0.3 PSI. These pressure thresholds are used to establish which simulations are classified as leaks at the leaking location and which locations away from the leak would constitute a signal. We observe 3 conclusions from the results: vertical flow barriers (heterogeneity) creates complicated pressure signals by forcing convoluted flow paths false positives (Pr( No Leak | Signal)) do not occur with our sample simulations false negatives (Pr( Leak | No signal)) dominate after 200 days even when considering only potential monitoring wells within 100m of the leaking well. We use these posteriors to calculate the value of information (VOI) from above zone pressure data. This work was performed under the auspices of the U.S. Department of Energy by

  14. Single-Shell Tank Leak Integrity Summary

    Energy Technology Data Exchange (ETDEWEB)

    Harlow, D. G. [Washington River Protection Solutions LLC, Richland, WA (United States); Girardot, C. L. [Washington River Protection Solutions LLC, Richland, WA (United States); Venetz, T. J. [Washington River Protection Solutions LLC, Richland, WA (United States)

    2015-03-26

    This document summarizes and evaluates the information in the Hanford Tri-Party Agreement Interim Milestone M-045-91F Targets completed between 2010 and 2015. 1) Common factors of SST liner failures (M-045-91F-T02), 2) the feasibility of testing for ionic conductivity between the inside and outside of SSTs (M-045-91F-T03, and 3) the causes, locations, and rates of leaks from leaking SSTs (M-045-91F-T04).

  15. Detection of Escherichia coli, Salmonella species, and Vibrio cholerae in tap water and bottled drinking water in Isfahan, Iran.

    Science.gov (United States)

    Momtaz, Hassan; Dehkordi, Farhad Safarpoor; Rahimi, Ebrahim; Asgarifar, Amin

    2013-06-07

    The quality of drinking water has an important role in human infection and disease. This study was aimed at comparing polymerase chain reaction and culture in detecting Escherichia coli, Salmonella species and Vibrio cholera in tape water and bottled drinking water in various seasons in Isfahan province, Iran. A total of 448 water samples from tap water and bottled mineral water were taken over 6 months, from July 2010 to December 2010, and after filtration, samples were examined by culture and polymerase chain reaction methods for detection of Escherichia coli, Salmonella species, and Vibrio cholerae. The culture method showed that 34 (7.58%), 4 (0.89%) and 3 (0.66%) of all 448 water samples were positive for Escherichia coli, Salmonella species, and Vibrio cholera, respectively. The uidA gene from Escherichia coli, IpaB gene from Salmonella species, and epsM gene from Vibrio cholera were detected in 38 (26.38%), 5 (3.47%), and 3 (2.08%) of 144 tap-water samples, respectively. Escherichia coli was detected in 8 (2.63%) of 304 samples of bottled drinking water from 5 companies. The water of southern part of Isfahan and company 5 had the highest prevalence of bacteria. The Escherichia coli water contamination was significantly higher (P waters of southern part and tap waters of central part of Isfahan. This study showed that the polymerase chain reaction assays can be an extremely accurate, fast, safe, sensitive and specific approach to monitor drinking water quality from purification facilities and bottled water companies. Also, our study confirmed the presence of Escherichia coli, Salmonella species, and Vibrio cholerae as water-borne pathogens in tap water and bottled drinking water of Isfahan, Iran. The present study showed the important public health problem in Isfahan, Iran.

  16. In-Line Acoustic Device Inspection of Leakage in Water Distribution Pipes Based on Wavelet and Neural Network

    Directory of Open Access Journals (Sweden)

    Dileep Kumar

    2017-01-01

    Full Text Available Traditionally permanent acoustic sensors leak detection techniques have been proven to be very effective in water distribution pipes. However, these methods need long distance deployment and proper position of sensors and cannot be implemented on underground pipelines. An inline-inspection acoustic device is developed which consists of acoustic sensors. The device will travel by the flow of water through the pipes which record all noise events and detect small leaks. However, it records all the noise events regarding background noises, but the time domain noisy acoustic signal cannot manifest complete features such as the leak flow rate which does not distinguish the leak signal and environmental disturbance. This paper presents an algorithm structure with the modularity of wavelet and neural network, which combines the capability of wavelet transform analyzing leakage signals and classification capability of artificial neural networks. This study validates that the time domain is not evident to the complete features regarding noisy leak signals and significance of selection of mother wavelet to extract the noise event features in water distribution pipes. The simulation consequences have shown that an appropriate mother wavelet has been selected and localized to extract the features of the signal with leak noise and background noise, and by neural network implementation, the method improves the classification performance of extracted features.

  17. Endoscopic management of bile leaks after laparoscopic ...

    African Journals Online (AJOL)

    2013-11-04

    Nov 4, 2013 ... abscesses, interloop and intra-abdominal sepsis and cholangitis, or the later secondary sequelae of biliary cirrhosis, portal hypertension and end-stage liver disease. There is consensus that optimal management of a bile duct injury requires multidisciplinary. Endoscopic management of bile leaks after.

  18. Early warning system for detection of protozoal contamination of source waters

    DEFF Research Database (Denmark)

    Al-Sabi, Mohammad Nafi Solaiman; Mogensen, Claus; Berg, Tommy W.

    2012-01-01

    water contamination e.g. water plants/water distribution networks, filtration systems (water purification), commercial buildings, swimming pools, and industry in general. Data from on-going field tests as well as sensitivity and specificity testing of the system will be presented at the conference.......Ensuring water quality is an ever increasing important issue world-wide. Currently, detection of protozoa in drinking water is a costly and time consuming process. We have developed an online, real-time sensor for detection of Cryptosporidium and Giardia spp. in a range of source waters. The novel...

  19. Optimised control and pipe burst detection by water demand forecasting

    NARCIS (Netherlands)

    Bakker, M.

    2014-01-01

    Water demand forecasting The total water demand in an area is the sum of the water demands of all individual domestic and industrial consumers in that area. These consumers behave in repetitive daily, weekly and annual patterns, and the same repetitive patterns can be observed in the drinking water

  20. Detection of Water Content in Rapeseed Leaves Using Terahertz Spectroscopy

    Directory of Open Access Journals (Sweden)

    Pengcheng Nie

    2017-12-01

    Full Text Available The terahertz (THz spectra of rapeseed leaves with different water content (WC were investigated. The transmission and absorption spectra in the range of 0.3–2 THz were measured by using THz time-domain spectroscopy. The mean transmittance and absorption coefficients were applied to analyze the change regulation of WC. In addition, the Savitzky-Golay method was performed to preprocess the spectra. Then, the partial least squares (PLS, kernel PLS (KPLS, and Boosting-PLS were conducted to establish models for predicting WC based on the processed transmission and absorption spectra. Reliable results were obtained by these three methods. KPLS generated the best prediction accuracy of WC. The prediction coefficient correlation (Rval and root mean square error (RMSEP of KPLS based on transmission were Rval = 0.8508, RMSEP = 0.1015, and that based on absorption were Rval = 0.8574, RMSEP = 0.1009. Results demonstrated that THz spectroscopy combined with modeling methods provided an efficient and feasible technique for detecting plant physiological information.

  1. REFLEAK: NIST Leak/Recharge Simulation Program for Refrigerant Mixtures

    Science.gov (United States)

    SRD 73 NIST REFLEAK: NIST Leak/Recharge Simulation Program for Refrigerant Mixtures (PC database for purchase)   REFLEAK estimates composition changes of zeotropic mixtures in leak and recharge processes.

  2. Optical Detection of Biological and Chemical Threats in Food and Water

    National Research Council Canada - National Science Library

    Nelson, Matthew P; Treado, Patrick J

    2006-01-01

    ...) and the Armed Forces Institute of Pathology (AFIP) have teamed on a 1 year project entitled "Optical Detection of Biological and Chemical Threats in Water and Food," to develop and validate waterborne pathogen detection technology in support...

  3. REAL-TIME PCR METHOD TO DETECT ENTEROCOCCUS FAECALIS IN WATER

    Science.gov (United States)

    A 16S rDNA real-time PCR method was developed to detect Enterococcus faecalis in water samples. The dynamic range for cell detection spanned five logs and the detection limit was determined to be 6 cfu/reaction. The assay was capable of detecting E. faecalis cells added to biof...

  4. Experiences with leak rate calculations methods for LBB application

    Energy Technology Data Exchange (ETDEWEB)

    Grebner, H.; Kastner, W.; Hoefler, A.; Maussner, G. [and others

    1997-04-01

    In this paper, three leak rate computer programs for the application of leak before break analysis are described and compared. The programs are compared to each other and to results of an HDR Reactor experiment and two real crack cases. The programs analyzed are PIPELEAK, FLORA, and PICEP. Generally, the different leak rate models are in agreement. To obtain reasonable agreement between measured and calculated leak rates, it was necessary to also use data from detailed crack investigations.

  5. In-service leak testing of district heating systems using dissolved tracer gas. Final report; Betriebsbegleitende Lecksuche mit geloestem Tracergas in Fernwaermesystemen. Abschlussbericht

    Energy Technology Data Exchange (ETDEWEB)

    Hergarten, A.; Althaus, W. [eds.

    1997-07-31

    The feasibility of in-service leak detection with dissolved tracer gas was investigated. Helium was selected as tracer gas because of its good diffusion characteristics, selective detectability at very low concentrations, inert and unproblematic behaviour within the district heating system, and good environmental compatibility. For a systematic investigation of the influencing parameters governing practical applications, a pipeline test field comprising about 240 m of KMR district heating pipelines and 61 controllable simulation leaks was constructed, and experiments using the new method were carried out. The required helium concentration amounts to a few grams of helium per cubic metre of district heating water. The water can be charged in the water preparation or feeding stage, and commercial detectors can be used. (orig./GL) [Deutsch] Zur Entwicklung einer betriebsbegleitenden Lecksuchmethode fuer erdverlegte Rohrleitungen wurden in einem Feasbility-Test die Machbarkeit der Tracergassuche mittels geloestem Spuergas bestaetigt. Als Tracergas wurde Helium aufgrund seines guenstigen Diffusionsverhaltens, seiner selektiven Nachweisbarkeit bei kleinsten Konzentrationen, seines inerten, unproblematischen Verhaltens im Fernwaermenetz und seiner guten Umweltvertraeglichkeit ausgewaehlt. Zur systematischen Untersuchung der Einflussparameter bei der Anwendung der Methode unter praxisnahen Bedingungen wurde ein Rohrleitungsversuchsfeld mit ca. 240 m KMR-Fernwaermeleitung und 61 regelbaren Simulationsleckagen aufgebaut und die neue Lecksuchmethode eingehend experimentell getestet. Die einzustellende Heliumkonzentration im Fernwaermewasser ist mit wenigen Gramm Helium je Kubikmeter Fernwaermewasser gering. Eine Vorrichtung fuer die empfohlene Beladung des gesamten Netzwasserinhalts kann in Wasseraufbereitung oder Nachspeisung des Netzes eingebunden werden. Zur Detektion koennen, marktverfuegbare Messgeraete verwendet werden. (orig./GL)

  6. Pipe leak diagnostic using high frequency piezoelectric pressure sensor and automatic selection of intrinsic mode function

    Science.gov (United States)

    Yusop, Hanafi M.; Ghazali, M. F.; Yusof, M. F. M.; Remli, M. A. Pi; Kamarulzaman, M. H.

    2017-10-01

    In a recent study, the analysis of pressure transient signals could be seen as an accurate and low-cost method for leak and feature detection in water distribution systems. Transient phenomena occurs due to sudden changes in the fluid’s propagation in pipelines system caused by rapid pressure and flow fluctuation due to events such as closing and opening valves rapidly or through pump failure. In this paper, the feasibility of the Hilbert-Huang transform (HHT) method/technique in analysing the pressure transient signals in presented and discussed. HHT is a way to decompose a signal into intrinsic mode functions (IMF). However, the advantage of HHT is its difficulty in selecting the suitable IMF for the next data postprocessing method which is Hilbert Transform (HT). This paper reveals that utilizing the application of an integrated kurtosis-based algorithm for a z-filter technique (I-Kaz) to kurtosis ratio (I-Kaz-Kurtosis) allows/contributes to/leads to automatic selection of the IMF that should be used. This technique is demonstrated on a 57.90-meter medium high-density polyethylene (MDPE) pipe installed with a single artificial leak. The analysis results using the I-Kaz-kurtosis ratio revealed/confirmed that the method can be used as an automatic selection of the IMF although the noise level ratio of the signal is low. Therefore, the I-Kaz-kurtosis ratio method is recommended as a means to implement an automatic selection technique of the IMF for HHT analysis.

  7. Double Shell Tank AY-102 Radioactive Waste Leak Investigation

    Energy Technology Data Exchange (ETDEWEB)

    Washenfelder, Dennis J.

    2014-04-10

    PowerPoint. The objectives of this presentation are to: Describe Effort to Determine Whether Tank AY-102 Leaked; Review Probable Causes of the Tank AY-102 Leak; and, Discuss Influence of Leak on Hanford’s Double-Shell Tank Integrity Program.

  8. 49 CFR 230.64 - Leaks under lagging.

    Science.gov (United States)

    2010-10-01

    ..., DEPARTMENT OF TRANSPORTATION STEAM LOCOMOTIVE INSPECTION AND MAINTENANCE STANDARDS Boilers and Appurtenances Steam Leaks § 230.64 Leaks under lagging. The steam locomotive owner and/or operator shall take out of service at once any boiler that has developed a leak under the lagging due to a crack in the shell, or to...

  9. 49 CFR 174.50 - Nonconforming or leaking packages.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 2 2010-10-01 2010-10-01 false Nonconforming or leaking packages. 174.50 Section 174.50 Transportation Other Regulations Relating to Transportation PIPELINE AND HAZARDOUS MATERIALS... General Operating Requirements § 174.50 Nonconforming or leaking packages. A leaking non-bulk package may...

  10. Parts-based geophysical inversion with application to water flooding interface detection and geological facies detection

    Science.gov (United States)

    Zhang, Junwei

    I built parts-based and manifold based mathematical learning model for the geophysical inverse problem and I applied this approach to two problems. One is related to the detection of the oil-water encroachment front during the water flooding of an oil reservoir. In this application, I propose a new 4D inversion approach based on the Gauss-Newton approach to invert time-lapse cross-well resistance data. The goal of this study is to image the position of the oil-water encroachment front in a heterogeneous clayey sand reservoir. This approach is based on explicitly connecting the change of resistivity to the petrophysical properties controlling the position of the front (porosity and permeability) and to the saturation of the water phase through a petrophysical resistivity model accounting for bulk and surface conductivity contributions and saturation. The distributions of the permeability and porosity are also inverted using the time-lapse resistivity data in order to better reconstruct the position of the oil water encroachment front. In our synthetic test case, we get a better position of the front with the by-products of porosity and permeability inferences near the flow trajectory and close to the wells. The numerical simulations show that the position of the front is recovered well but the distribution of the recovered porosity and permeability is only fair. A comparison with a commercial code based on a classical Gauss-Newton approach with no information provided by the two-phase flow model fails to recover the position of the front. The new approach could be also used for the time-lapse monitoring of various processes in both geothermal fields and oil and gas reservoirs using a combination of geophysical methods. A paper has been published in Geophysical Journal International on this topic and I am the first author of this paper. The second application is related to the detection of geological facies boundaries and their deforation to satisfy to geophysica

  11. Emergency management of heat exchanger leak on cardiopulmonary bypass with hypothermia.

    Science.gov (United States)

    Gukop, P; Tiezzi, A; Mattam, K; Sarsam, M

    2015-11-01

    Heat exchanger leak on cardiopulmonary bypass is very rare, but serious. The exact incidence is not known. It is an emergency associated with the potential risk of blood contamination, air embolism and haemolysis, difficulty with re-warming, acidosis, subsequent septic shock, multi-organ failure and death. We present a prompt, highly co-ordinated algorithm for the successful management of this important rare complication. There is need for further research to look for safety devices that detect leaks and techniques to reduce bacterial load. It is essential that teams practice oxygenator change-out routines and have a well-established change-out protocol. © The Author(s) 2015.

  12. Leak-off mechanism and pressure prediction for shallow sediments in deepwater drilling

    Science.gov (United States)

    Tan, Qiang; Deng, Jingen; Sun, Jin; Liu, Wei; Yu, Baohua

    2018-02-01

    Deepwater sediments are prone to loss circulation in drilling due to a low overburden gradient. How to predict the magnitude of leak-off pressure more accurately is an important issue in the protection of drilling safety and the reduction of drilling cost in deep water. Starting from the mechanical properties of a shallow formation and based on the basic theory of rock-soil mechanics, the stress distribution around a borehole was analyzed. It was found that the rock or soil on a borehole is in the plastic yield state before the effective tensile stress is generated, and the effective tangential and vertical stresses increase as the drilling fluid density increases; thus, tensile failure will not occur on the borehole wall. Based on the results of stress calculation, two mechanisms and leak-off pressure prediction models for shallow sediments in deepwater drilling were put forward, and the calculated values of these models were compared with the measured value of shallow leak-off pressure in actual drilling. The results show that the MHPS (minimum horizontal principle stress) model and the FIF (fracturing in formation) model can predict the lower and upper limits of leak-off pressure. The PLC (permeable lost circulation) model can comprehensively analyze the factors influencing permeable leakage and provide a theoretical basis for leak-off prevention and plugging in deepwater drilling.

  13. Real-time electronic monitoring of a pitted and leaking gas gathering pipeline

    Energy Technology Data Exchange (ETDEWEB)

    Asperger, R.G.; Hewitt, P.G.

    1986-08-01

    Hydrogen patch, flush electrical resistance, and flush linear polarization proves wre used with flush coupons to monitor corrosion rates in a pitted and leaking sour gas gathering line. Four inhibitors were evaluated in stopping the leaks. Inhibitor residuals and the amount and ratio of water and condensate in the lines were measured at five locations along the line. The best inhibitor reduced reduced the pit-leak frequency by over a factor of 10. Inhibitor usage rate was optimized using the hydrogen patch current as a measure of the instantaneous corrosion rate. Improper pigging was identified as a cause of corrosion transients. This problem is discussed in relation to the pigging of pipelines in stratified flow where moving fluids are the carriers for continuously injected corrosion inhibitors.

  14. He leaks in the CERN LHC beam vacuum chambers operating at cryogenic temperatures

    CERN Document Server

    Baglin, V

    2007-01-01

    The 27 km long large hadron collider (LHC), currently under construction at CERN, will collide protons beam at 14 TeV in the centre of mass. In the 8 arcs, the superconducting dipoles and quadrupoles of the FODO cells operate with superfluid He at 1.9 K. In the 8 long straight sections, the cold bores of the superconducting magnets are held at 1.9 or 4.5 K. Thus, in the LHC, 75% of the beam tube vacuum chamber is cooled with He. In many areas of the machine, He leaks could appear in the beam tube. At cryogenic temperature, the gas condenses onto the cold bores or beam screens, and interacts with the circulating beam. He leaks creates a He front propagating along the vacuum chambers, which might cause magnet quench. We discuss the consequences of He leaks, the possible means of detections, the strategies to localise them and the methods to measure their size.

  15. A new method of leak location for the natural gas pipeline based on wavelet analysis

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Zhao; Xiong, Zhuang; Shao, Min [Thermal Energy Research Institute, School of Mechanical Engineering, Tianjin University, Nankai District, Tianjin 300072 (China)

    2010-09-15

    This paper analyzes the properties of wavelet transform and its potential application in detecting the leakage location of gas pipeline. An entity-part method, which is proposed for the accurate leaking point, has been proved valid in the stimulation experiment. In addition, method of Romberg and Dichotomy Searching are also adopted for the computational analysis of leaking point. In detail, the effect of gas velocity is taken into consideration in the location formula and we propose to consider the average velocities of two parts caused by the leaking point, respectively. Finally, we test these three methods in a real gas pipeline experiment and the result shows the improvement to some extent in contrast to the traditional approach. (author)

  16. Toxic cyanobacteria and drinking water: Impacts, detection, and treatment.

    Science.gov (United States)

    He, Xuexiang; Liu, Yen-Ling; Conklin, Amanda; Westrick, Judy; Weavers, Linda K; Dionysiou, Dionysios D; Lenhart, John J; Mouser, Paula J; Szlag, David; Walker, Harold W

    2016-04-01

    Blooms of toxic cyanobacteria in water supply systems are a global issue affecting water supplies on every major continent except Antarctica. The occurrence of toxic cyanobacteria in freshwater is increasing in both frequency and distribution. The protection of water supplies has therefore become increasingly more challenging. To reduce the risk from toxic cyanobacterial blooms in drinking water, a multi-barrier approach is needed, consisting of prevention, source control, treatment optimization, and monitoring. In this paper, current research on some of the critical elements of this multi-barrier approach are reviewed and synthesized, with an emphasis on the effectiveness of water treatment technologies for removing cyanobacteria and related toxic compounds. This paper synthesizes and updates a number of previous review articles on various aspects of this multi-barrier approach in order to provide a holistic resource for researchers, water managers and engineers, as well as water treatment plant operators. Copyright © 2016 Elsevier B.V. All rights reserved.

  17. Fishing in the Water: Effect of Sampled Water Volume on Environmental DNA-Based Detection of Macroinvertebrates.

    Science.gov (United States)

    Mächler, Elvira; Deiner, Kristy; Spahn, Fabienne; Altermatt, Florian

    2016-01-05

    Accurate detection of organisms is crucial for the effective management of threatened and invasive species because false detections directly affect the implementation of management actions. The use of environmental DNA (eDNA) as a species detection tool is in a rapid development stage; however, concerns about accurate detections using eDNA have been raised. We evaluated the effect of sampled water volume (0.25 to 2 L) on the detection rate for three macroinvertebrate species. Additionally, we tested (depending on the sampled water volume) what amount of total extracted DNA should be screened to reduce uncertainty in detections. We found that all three species were detected in all volumes of water. Surprisingly, however, only one species had a positive relationship between an increased sample volume and an increase in the detection rate. We conclude that the optimal sample volume might depend on the species-habitat combination and should be tested for the system where management actions are warranted. Nevertheless, we minimally recommend sampling water volumes of 1 L and screening at least 14 μL of extracted eDNA for each sample to reduce uncertainty in detections when studying macroinvertebrates in rivers and using our molecular workflow.

  18. Detection of microbial contaminations in drinking water using ATP measurements – evaluating potential for online monitoring

    DEFF Research Database (Denmark)

    Vang, Óluva Karin; Corfitzen, Charlotte B.; Albrechtsen, Hans-Jørgen

    2011-01-01

    There is an increasing call for fast and reliable methods for continuous monitoring of microbial drinking water quality in order to protect public health. The potential for Adenosine triphosphate (ATP) measurements as a real-time analysis for continuous monitoring of microbial drinking water...... of reagent kit. Surface water diluted 100-1000 times was detected in drinking water with ATP measurements. ATP has the potential as an early warning tool, especially in the period when the contamination concentration is high. 2011 © American Water Works Association AWWA WQTC Conference Proceedings All Rights...... quality was investigated through simulation of two contamination scenarios, i.e. drinking water contaminated with waste water and surface water at various concentrations. With ATP measurements it was possible to detect waste water diluted 1000-10,000 times in drinking water depending on sensitivity...

  19. Method for mapping a natural gas leak

    Science.gov (United States)

    Reichardt, Thomas A [Livermore, CA; Luong, Amy Khai [Dublin, CA; Kulp, Thomas J [Livermore, CA; Devdas, Sanjay [Albany, CA

    2009-02-03

    A system is described that is suitable for use in determining the location of leaks of gases having a background concentration. The system is a point-wise backscatter absorption gas measurement system that measures absorption and distance to each point of an image. The absorption measurement provides an indication of the total amount of a gas of interest, and the distance provides an estimate of the background concentration of gas. The distance is measured from the time-of-flight of laser pulse that is generated along with the absorption measurement light. The measurements are formatted into an image of the presence of gas in excess of the background. Alternatively, an image of the scene is superimposed on the image of the gas to aid in locating leaks. By further modeling excess gas as a plume having a known concentration profile, the present system provides an estimate of the maximum concentration of the gas of interest.

  20. An AEM survey of a leaking landfill

    OpenAIRE

    Beamish, D

    2005-01-01

    This study presents results obtained from a remarkably small-scale helicopter airborne electromagnetic (AEM) survey of a closed landfill. The landfill, occupying a former quarry, is situated among shallow, worked-out coal seams (pillar and stall workings) and was located over at least two mineshafts that occupied the quarry floor. The landfill was known to be leaking from an extensive borehole investigation that took place in the 1970’s, when the landfill was active. Redevelopment issues and ...

  1. Regulated tailored suction vs regulated seal: a prospective randomized trial on air leak duration.

    Science.gov (United States)

    Brunelli, Alessandro; Salati, Michele; Pompili, Cecilia; Refai, Majed; Sabbatini, Armando

    2013-05-01

    The objective of this study was to compare the air leak duration of two regulated chest tube modes following pulmonary lobectomy. This is a prospective randomized trial on 100 consecutive pulmonary lobectomies (2010-11) performed for lung cancer. A single 24-French chest tube was connected to an electronic system capable of maintaining the pleural pressure within preset values (regulated suction mode) or within a physiological range (regulated seal mode). Patients were randomized to two groups: Group 1, regulated individualized suction (range: -11 to -20 cmH2O, according to lobectomy type); Group 2, regulated seal (-2 cmH2O). The main endpoint was the duration of air leak (h) calculated from the end of the operation to a value consistently below 20 ml/min. Patients with prolonged air leak (>168 h) were connected to a portable device before discharge. Their air leak duration was considered as 192 h. The sample size was calculated to detect 1-day difference in air leak duration with a statistical power of 80%. The two groups were well matched for several baseline and surgical characteristics. No crossovers occurred between groups. The average air leak duration (Group 1: 28 vs Group 2: 22.2, P = 0.6), and the number of patients with prolonged air leak (Group 1: 5 vs Group 2: 4, P = 0.7) and with other complications (Group 1: 6 patients vs Group 2: 7 patients, P = 0.9) were similar between the groups. Sixteen patients of Group 1 and 21 of Group 2 had an air leak present immediately after extubation. Among them, patients of Group 2 (regulated seal) had an air leak lasting 34.5 h less than those of Group 1 (regulated suction) (52.9 vs 87.4, P = 0.07). Regulated seal is as effective and safe as regulated suction in managing chest tubes following lobectomy. This information demonstrates with objective data the non-superiority of regulated suction vs regulated seal and may assist in future investigations on regulated pleural pressure.

  2. PCR detection of Burkholderia multivorans in water and soil samples

    OpenAIRE

    Peeters, C.; Daenekindt, S. (Stijn); Vandamme, Anne Mieke

    2016-01-01

    Background Although semi-selective growth media have been developed for the isolation of Burkholderia cepacia complex bacteria from the environment, thus far Burkholderia multivorans has rarely been isolated from such samples. Because environmental B. multivorans isolates mainly originate from water samples, we hypothesized that water rather than soil is its most likely environmental niche. The aim of the present study was to assess the occurrence of B. multivorans in water samples from Fland...

  3. Detection of contamination of municipal water distribution systems

    Science.gov (United States)

    Cooper, John F [Oakland, CA

    2012-01-17

    A system for the detection of contaminates of a fluid in a conduit. The conduit is part of a fluid distribution system. A chemical or biological sensor array is connected to the conduit. The sensor array produces an acoustic signal burst in the fluid upon detection of contaminates in the fluid. A supervisory control system connected to the fluid and operatively connected to the fluid distribution system signals the fluid distribution system upon detection of contaminates in the fluid.

  4. Operational Surface Water Detection and Monitoring Using Radarsat 2

    Directory of Open Access Journals (Sweden)

    Sandra Bolanos

    2016-03-01

    Full Text Available Traditional on-site methods for mapping and monitoring surface water extent are prohibitively expensive at a national scale within Canada. Despite successful cost-sharing programs between the provinces and the federal government, an extensive number of water features within the country remain unmonitored. Particularly difficult to monitor are the potholes in the Canadian Prairie region, most of which are ephemeral in nature and represent a discontinuous flow that influences water pathways, runoff response, flooding and local weather. Radarsat-2 and the Radarsat Constellation Mission (RCM offer unique capabilities to map the extent of water bodies at a national scale, including unmonitored sites, and leverage the current infrastructure of the Meteorological Service of Canada to monitor water information in remote regions. An analysis of the technical requirements of the Radarsat-2 beam mode, polarization and resolution is presented. A threshold-based procedure to map locations of non-vegetated water bodies after the ice break-up is used and complemented with a texture-based indicator to capture the most homogeneous water areas and automatically delineate their extents. Some strategies to cope with the radiometric artifacts of noise inherent to Synthetic Aperture Radar (SAR images are also discussed. Our results show that Radarsat-2 Fine mode can capture 88% of the total water area in a fully automated way. This will greatly improve current operational procedures for surface water monitoring information and impact a number of applications including weather forecasting, hydrological modeling, and drought/flood predictions.

  5. Method detection limit determination and application of a convenient headspace analysis method for methyl tert-butyl ether in water.

    Science.gov (United States)

    O'Neill, Dennis T; Rochette, Elizabeth A; Ramsey, Philip J

    2002-11-15

    Methyl tert-butyl ether (MTBE) is a common groundwater contaminant, introduced to the environment by leaking petroleum storage tanks, urban runoff, and motorized watercraft. In this study. a simplified (static) headspace analysis method was adapted for determination of MTBE in water samples and soil water extracts. The MDL of the headspace method was calculated to be 2.0 microg L(-1) by the EPA single-concentration design method(1) and 1.2 microg L(-1) by a calibration method developed by Hubaux and Vos (Hubaux, A.; Vos, G. Anal. Chem. 1970,42, 849-855). The MDL calculated with the Hubaux and Vos method was favored because it considers both a true positive and a false positive. The static headspace method was applied to analysis of a tap water sample and a monitoring well sample from a gasoline service station, a river sample, and aqueous extracts from soil excavated during removal of a leaking underground storage tank (LUST). The water samples examined in this study had MTTBE concentrations ranging from 6 to 19 microg L(-1). Aqueous extracts of a soil sample taken from the LUST site had 8 microg L(-1) MTBE.

  6. Bisphenol A Detection in Various Brands of Drinking Bottled Water ...

    African Journals Online (AJOL)

    Purpose: To assess whether bisphenol A contamination occurred in seven brands of bottled drinking water in Riyadh, Saudi Arabia. Methods: Liquid-liquid extraction (using dichloromethane) was used to analytically extract bisphenol A from drinking water bottles and a gas chromatograph-mass spectrometer was employed ...

  7. A Shazam-like Household Water Leakage Detection Method

    NARCIS (Netherlands)

    Seyoum, S.D.; Alfonso, Leonardo; Andel, Schalk Jan Van; Koole, W.; Groenewegen, A.C.; van de Giesen, N.C.

    2017-01-01

    Waternomics is a European Union-funded research project aspiring to develop and introduce Information and Communication Technology (ICT) as an enabling technology to manage water as a resource, increase end-user conservation awareness, affect behavioural changes and avoid water losses through

  8. Water body extraction and change detection based on multi-temporal SAR images

    Science.gov (United States)

    Zhang, Zhaohui; Lu, Hanqing; Zhao, Minghua; Zhao, Lei; Zhen, Huiling

    2009-10-01

    This paper proposed an unsupervised change detection method for water body extraction and change detection with multi-temporal SAR images. Firstly, two optimal thresholds are estimated according to the strategy of maximum mutual information, in which computation efficiency is largely improved based on integral image. Secondly, water body extraction is done simultaneously in both input images by optimal thresholds. Finally, by fusing of two segmented results, change detection can be achieved. Experimental results demonstrate the effectiveness of the proposed approach.

  9. Design of an Infrared Imaging System for Robotic Inspection of Gas Leaks in Industrial Environments

    Directory of Open Access Journals (Sweden)

    Ramon Barber

    2015-03-01

    Full Text Available Gas detection can become a critical task in dangerous environments that involve hazardous or contaminant gases, and the use of imaging sensors provides an important tool for leakage location. This paper presents a new design for remote sensing of gas leaks based on infrared (IR imaging techniques. The inspection system uses an uncooled microbolometer detector, operating over a wide spectral bandwidth, that features both low size and low power consumption. This equipment is boarded on a robotic platform, so that wide objects or areas can be scanned. The detection principle is based on the use of active imaging techniques, where the use of external IR illumination enhances the detection limit and allows the proposed system to operate in most cases independently from environmental conditions, unlike passive commercial approaches. To illustrate this concept, a fully radiometric description of the detection problem has been developed; CO2 detection has been demonstrated; and simulations of typical gas detection scenarios have been performed, showing that typical industrial leaks of CH4 are well within the detection limits. The mobile platform where the gas sensing system is going to be implemented is a robot called TurtleBot. The control of the mobile base and of the inspection device is integrated in ROS architecture. The exploration system is based on the technique of Simultaneous Localization and Mapping (SLAM that makes it possible to locate the gas leak in the map.

  10. Presence of Cryptosporidium parvum and Giardia lamblia in water samples from Southeast Asia: towards an integrated water detection system.

    Science.gov (United States)

    Kumar, Thulasi; Abd Majid, Mohamad Azlan; Onichandran, Subashini; Jaturas, Narong; Andiappan, Hemah; Salibay, Cristina C; Tabo, Hazel A L; Tabo, Norbel; Dungca, Julieta Z; Tangpong, Jitbanjong; Phiriyasamith, Sucheep; Yuttayong, Boonyaorn; Polseela, Raxsina; Do, Binh Nhu; Sawangjaroen, Nongyao; Tan, Tian-Chye; Lim, Yvonne A L; Nissapatorn, Veeranoot

    2016-01-13

    Access to clean and safe drinking water that is free from pathogenic protozoan parasites, especially Cryptosporidium parvum and Giardia lamblia that cause gastrointestinal illness in humans, is still an issue in Southeast Asia (SEA). This study is the first attempt to detect the aforementioned protozoan parasites in water samples from countries in SEA, using real-time polymerase chain reaction (qPCR) assays. A total of 221 water samples of 10 l each were collected between April and October 2013 from Malaysia (53), Thailand (120), the Philippines (33), and Vietnam (15). A physicochemical analysis was conducted. The water samples were processed in accordance with the US Environmental Protection Agency's methods 1622/1623.1, microscopically observed and subsequently screened using qPCR assays. Cryptosporidium oocysts were detected in treated water samples from the Philippines (1/10), with a concentration of 0.06 ± 0.19 oocyst/L, and untreated water samples from Thailand (25/93), Malaysia (17/44), and the Philippines (11/23), with concentrations ranging from 0.13 ± 0.18 to 0.57 ± 1.41 oocyst/L. Giardia cysts were found in treated water samples from the Philippines (1/10), with a concentration of 0.02 ± 0.06 cyst/L, and in untreated water samples from Thailand (20/93), Vietnam (5/10), Malaysia (22/44), and the Philippines (16/23), with concentrations ranging from 0.12 ± 0.3 to 8.90 ± 19.65 cyst/L. The pathogens C. parvum and G. lamblia were detected using using qPCR assays by targeting the 138-bp fragment and the small subunit gene, respectively. C. parvum was detected in untreated water samples from the Philippines (1/23) and Malaysia (2/44), whilst, G. lamblia detected was detected in treated water samples from the Philippines (1/10) and in untreated water samples from Thailand (21/93), Malaysia (12/44), and the Philippines (17/23). Nitrate concentration was found to have a high positive correlation with (oo)cyst (0.993). The presence of

  11. Remote detection of widespread indigenous water in lunar pyroclastic deposits

    Science.gov (United States)

    Milliken, Ralph E.; Li, Shuai

    2017-08-01

    Laboratory analyses of lunar samples provide a direct means to identify indigenous volatiles and have been used to argue for the presence of Earth-like water content in the lunar interior. Some volatile elements, however, have been interpreted as evidence for a bulk lunar mantle that is dry. Here we demonstrate that, for a number of lunar pyroclastic deposits, near-infrared reflectance spectra acquired by the Moon Mineralogy Mapper instrument onboard the Chandrayaan-1 orbiter exhibit absorptions consistent with enhanced OH- and/or H2O-bearing materials. These enhancements suggest a widespread occurrence of water in pyroclastic materials sourced from the deep lunar interior, and thus an indigenous origin. Water abundances of up to 150 ppm are estimated for large pyroclastic deposits, with localized values of about 300 to 400 ppm at potential vent areas. Enhanced water content associated with lunar pyroclastic deposits and the large areal extent, widespread distribution and variable chemistry of these deposits on the lunar surface are consistent with significant water in the bulk lunar mantle. We therefore suggest that water-bearing volcanic glasses from Apollo landing sites are not anomalous, and volatile loss during pyroclastic eruptions may represent a significant pathway for the transport of water to the lunar surface.

  12. [Detection of Cryptospordium spp. in environmental water samples by FTA-PCR].

    Science.gov (United States)

    Zhang, Xiao-Ping; Zhu, Qian; He, Yan-Yan; Jiang, Li; Jiang, Shou-Fu

    2011-02-01

    To establish a FTA-polymeras chain reaction (FTA-PCR) method in detection of Cryptospordium spp. in different sources of water. The semi automated immunomagnetic separation (IMS) of Cryptospordium oocysts in environmental water samples was performed firstly, and then genomic DNA of Cryptospordium oocysts was extracted by FTA filters disk. Oligonucleotide primers were designed based on the DNA fragment of the 18 S rRNA gene from C. parvum. Plate DNA was amplified with primers in PCR. The control DNA samples from Toxoplasma gondii,Sarcocystis suihominis, Echinococcus granulosus, and Clonorchis sinensis were amplified simultaneously. All PCR products were detected by agar electrophoresis dyed with ethidium bromide. The 446 bp fragment of DNA was detected in all samples of C. parvum, C. andersoni, and C. baileyi, while it was not detected in control groups in laboratory. No positive samples were found from 10 samples collected from tape water in 5 districts of Shanghai City by FTA-PCR. Nine positive samples were detected totally from 70 different environmental water samples, there were 0 out of 15 samples from the source of tape water, 2 out of 25 from the Huangpu River, 5 out of 15 from rivers around the animal farmers, 1 out of 9 from output water of contaminating water treatment factory, 1 out of 6 from the out gate of living contaminating water. The 446 bp fragment was detected from all the amplified positive water samples. FTA-PCR is an efficient method for gene detection of Cryptospordium oocysts, which could be used in detection of environmental water samples. The contamination degree of Cryptospordium oocysts in the river water around animal farms is high.

  13. Patulin detection from Penicillia in bottled water commodity system

    OpenAIRE

    Paterson, R. R. M.; Ribeiro, Ana; Venâncio, Armando; Lima, Nelson

    2004-01-01

    Control of Mycological Contaminants of BOttled Water (COMBOW) is an EU-CRAFT project which is investigating the significance of fungi to this commodity. Some fungi produce toxins (mycotoxins). These compounds contaminate food and drink with detrimental effects on human health and economies. Mycotoxins have been reported recently in stored water and production confirmed in vitro. Patulin is a mycotoxin and has been regulated by the EU since 1 November 2003 in apple juice and ingredients. Penic...

  14. LEAK: A source term generator for evaluating release rates from leaking vessels

    Energy Technology Data Exchange (ETDEWEB)

    Clinton, J.H.

    1994-09-01

    An interactive computer code for estimating the rate of release of any one of several materials from a leaking tank or broken pipe leading from a tank is presented. It is generally assumed that the material in the tank is liquid. Materials included in the data base are acetonitrile, ammonia, carbon tetrachloride, chlorine, chlorine trifluoride, fluorine, hydrogen fluoride, nitric acid, nitrogen tetroxide, sodium hydroxide, sulfur hexafluoride, sulfuric acid, and uranium hexafluoride. Materials that exist only as liquid and/or vapor over expected ranges of temperature and pressure can easily be added to the data base file. The Fortran source code for LEAK and the data file are included with this report.

  15. Management of primary-to-secondary leaks at Loviisa nuclear power plant

    Energy Technology Data Exchange (ETDEWEB)

    Mohnsen, B.; Jaenkaelae, K. [IVO International Ltd, Vantaa (Finland)

    1995-12-31

    The Loviisa Nuclear power plant consisting of two VVER-440 type press water reactor units has been in commercial operation since the late 1970`s. Specific features for VVER-440 reactors are six primary loops with horizontal steam generators and main gate valves. The structure of the horizontal steam generators construction may cause a large primary to secondary leak in case of a break in the cover of the primary collector. An accident where two primary collector covers opened totally and two covers opened partly took place in Rovno, Ukraine January 1982. Primary to secondary leaks are one of the main contributors to the core melt frequency in VVER reactors according to the Loviisa 1 Probabilistic Safety Assessment. The high core damage contribution has set requirements for the development of effective means to cope with all sizes of primary to secondary leaks in the steam generator. A concept for all leak sizes has been developed for Loviisa 1 and 2. The solution includes four main areas which are a new steam generator leakage monitoring system based on nitrogen-16 measurement, an upgraded pressurizer spray system, an increased emergency cooling water reserve and an automated isolation of the defected steam generator.

  16. [Detection of oil spills on water by differential polarization FTIR spectrometry].

    Science.gov (United States)

    Yuan, Yue-ming; Xiong, Wei; Fang, Yong-hua; Lan, Tian-ge; Li, Da-cheng

    2010-08-01

    Detection of oil spills on water, by traditional thermal remote sensing, is based on the radiance contrast between the large area of clean water and the polluted area of water. And the categories of oil spills can not be identified by analysing the thermal infrared image. In order to find out the extent of pollution and identify the oil contaminants, an approach to the passive detection of oil spills on water by differential polarization FTIR spectrometry is proposed. This approach can detect the contaminants by obtaining and analysing the subtracted spectrum of horizontal and vertical polarization intensity spectrum. In the present article, the radiance model of differential polarization FTIR spectrometry is analysed, and an experiment about detection of No. O diesel and SF96 film on water by this method is presented. The results of this experiment indicate that this method can detect the oil contaminants on water without radiance contrast with clean water, and it also can identify oil spills by analysing the spectral characteristic of differential polarization FTIR spectrum. So it well makes up for the shortage of traditional thermal remote sensing on detecting oil spills on water.

  17. Detection of Intestinal Pathogens in River, Shore, and Drinking Water in Lima, Peru.

    Science.gov (United States)

    Grothen, David C; Zach, Sydney J; Davis, Paul H

    2017-01-01

    Water quality management is an ongoing struggle for many locations worldwide. Current testing of water supplies can be time-consuming, expensive, and lack sensitivity. This study describes an alternative, easy-to-use, and inexpensive method to water sampling and testing at remote locations. This method was employed to detect a number of intestinal pathogens in various locations of Lima, Peru. A total of 34 PCR primer pairs were tested for specificity and high-yield amplification for 12 different pathogens using known DNA templates. Select primers for each pathogen were then tested for minimum detection limits of DNA. Water samples were collected from 22 locations. PCR was used to detect the presence of a pathogen, virulence factors, or differentiate between pathogenic species. In 22 water samples, cholera toxin gene was detected in 4.5% of samples, C. perfringens DNA was detected in 50% of samples, E. histolytica DNA was detected in 54.5% of samples, Giardia intestinalis DNA was detected in 4.5% of samples, Leptospira spp. DNA was detected in 29% of samples, and T. gondii DNA was detected in 31.8% of samples. DNA from three pathogens, C. perfringens, E. histolytica, and T. gondii, were found in residential samples, which accounted for 10 out of 22 samples.

  18. Rapid and Highly Sensitive Detection of Lead Ions in Drinking Water Based on a Strip Immunosensor

    Directory of Open Access Journals (Sweden)

    Chuanlai Xu

    2013-03-01

    Full Text Available In this study, we have first developed a rapid and sensitive strip immunosensor based on two heterogeneously-sized gold nanoparticles (Au NPs probes for the detection of trace lead ions in drinking water. The sensitivity was 4-fold higher than that of the conventional LFA under the optimized conditions. The visual limit of detection (LOD of the amplified method for qualitative detection lead ions was 2 ng/mL and the LOD for semi-quantitative detection could go down to 0.19 ng/mL using a scanning reader. The method suffered from no interference from other metal ions and could be used to detect trace lead ions in drinking water without sample enrichment. The recovery of the test samples ranged from 96% to 103%. As the detection method could be accomplished within 15 min, this method could be used as a potential tool for preliminary monitoring of lead contamination in drinking water.

  19. Rapid and highly sensitive detection of lead ions in drinking water based on a strip immunosensor.

    Science.gov (United States)

    Kuang, Hua; Xing, Changrui; Hao, Changlong; Liu, Liqiang; Wang, Libing; Xu, Chuanlai

    2013-03-28

    In this study, we have first developed a rapid and sensitive strip immunosensor based on two heterogeneously-sized gold nanoparticles (Au NPs) probes for the detection of trace lead ions in drinking water. The sensitivity was 4-fold higher than that of the conventional LFA under the optimized conditions. The visual limit of detection (LOD) of the amplified method for qualitative detection lead ions was 2 ng/mL and the LOD for semi-quantitative detection could go down to 0.19 ng/mL using a scanning reader. The method suffered from no interference from other metal ions and could be used to detect trace lead ions in drinking water without sample enrichment. The recovery of the test samples ranged from 96% to 103%. As the detection method could be accomplished within 15 min, this method could be used as a potential tool for preliminary monitoring of lead contamination in drinking water.

  20. Cassette bacteria detection system. [for monitoring the sterility of regenerated water in spacecraft

    Science.gov (United States)

    1974-01-01

    The design, fabrication, and testing of an automatic bacteria detection system, with a zero-g capability, based on the filter-capable approach, and intended for monitoring the sterility of regenerated water in spacecraft is discussed. The principle of detection is based on measuring the increase in chemiluminescence produced by the action of bacterial porphyrins on a luminol-hydrogen peroxide mixture. Viable organisms are detected by comparing the signal of an incubated water sample with an unincubated control. High signals for the incubated water sample indicate the presence of viable organisms.

  1. Method of and device for detecting oil pollutions on water surfaces

    Science.gov (United States)

    Belov, Michael Leonidovich [Moscow, RU; Gorodnichev, Victor Aleksandrovich [Moscow, RU; Kozintsev, Valentin Ivanovich [Moscow, RU; Smimova, Olga Alekseevna [Moscow, RU; Fedotov, Yurii Victorovich [Moscow, RU; Khroustaleva, Anastasiva Michailovnan [Moscow, RU

    2008-08-26

    Detection of oil pollution on water surfaces includes providing echo signals obtained from optical radiation of a clean water area at two wavelengths, optically radiating an investigated water area at two wavelengths and obtaining echo signals from the optical radiation of the investigated water area at the two wavelengths, comparing the echo signals obtained from the radiation of the investigated area at two wavelengths with the echo signals obtained from the radiation of the clean water area, and based on the comparison, determining presence or absence of oil pollution in the investigated water area.

  2. Evaluation of Handheld Assays for the Detection of Ricin and Staphylococcal Enterotoxin B in Disinfected Waters

    Directory of Open Access Journals (Sweden)

    Mary Margaret Wade

    2011-01-01

    Full Text Available Development of a rapid field test is needed capable of determining if field supplies of water are safe to drink by the warfighter during a military operation. The present study sought to assess the effectiveness of handheld assays (HHAs in detecting ricin and Staphylococcal Enterotoxin B (SEB in water. Performance of HHAs was evaluated in formulated tap water with and without chlorine, reverse osmosis water (RO with chlorine, and RO with bromine. Each matrix was prepared, spiked with ricin or SEB at multiple concentrations, and then loaded onto HHAs. HHAs were allowed to develop and then read visually. Limits of detection (LOD were determined for all HHAs in each water type. Both ricin and SEB were detected by HHAs in formulated tap water at or below the suggested health effect levels of 455 ng/mL and 4.55 ng/mL, respectively. However, in brominated or chlorinated waters, LODs for SEB increased to approximately 2,500 ng/mL. LODs for ricin increased in chlorinated water, but still remained below the suggested health effect level. In brominated water, the LOD for ricin increased to approximately 2,500 ng/mL. In conclusion, the HHAs tested were less effective at detecting ricin and SEB in disinfected water, as currently configured.

  3. Detection Performance of Horizontal Linear Hydrophone Arrays in Shallow Water.

    Science.gov (United States)

    1980-12-15

    Director of SACLANTCEN. 81 4 20 001 L ~. 0 7 This document is released to a NATO Government at the direction of the S CLANTCF subject to the following...almost independent of the channel parameters ( soun ?-, peed profile, depth of water, source, receiver, frequency). b. As the matrix matched filter H

  4. Water stress detection in the Amazon using radar

    NARCIS (Netherlands)

    van Emmerik, T.H.M.; Steele-Dunne, S.C.; Paget, Aaron; Oliveira, Rafael S.; Bittencourt, Paulo R.L.; Barros, Fernanda de V.; van de Giesen, N.C.

    2017-01-01

    The Amazon rainforest plays an important role in the global water and carbon cycle, and though it is predicted to continue drying in the future, the effect of drought remains uncertain. Developments in remote sensing missions now facilitate large-scale observations. The RapidScat scatterometer

  5. COMPOSITE SAMPLING FOR DETECTION OF COLIFORM BACTERIA IN WATER SUPPLY

    Science.gov (United States)

    Low densities of coliform bacteria introduced into distribution systems may survive in protected habitats. These organisms may interfere with and cause confusion in the use of the coliforms as indicators of sewage contamination of drinking water. Methods of increasing the probabi...

  6. Detection and enumeration of Coliforms and Escherichia coli in water

    African Journals Online (AJOL)

    Water samples from eighteen different sources in Nairobi were analyzed for coliform and E. coli content using three microbiological techniques, namely: Multiple tube or Most Probable Number (MPN) technique, Defined Substrate Technique (DST) or Colilert technique and Petrifilm(TM) Plate Count Techniques. All the three ...

  7. Detecting Oil on Water: A Comparison of Known Techniques

    Science.gov (United States)

    Klemas, Vytautas

    1971-01-01

    This paper reviews new developments in oil pollution detection and compares available techniques according to their effectiveness. Emphasis is on in situ and remote sensing techniques, with a potential for real-time, automated operation. No mention is made of traditional methods, requiring that a sample be taken to a laboratory for tests of solubility, chemical reactions, or other properties.

  8. Detection of Pseudomonas fluorescens from broth, water and ...

    African Journals Online (AJOL)

    Loop mediated isothermal amplification is rapid, highly sensitive and specifically developed method for detection of bacterial infections. AprX gene for alkaline metalloprotease of Pseudomonas fluorescens was used to design four primers and loop mediated isothermal amplification (LAMP) conditions were standardized for ...

  9. Colorimetric peroxidase mimetic assay for uranyl detection in sea water

    KAUST Repository

    Zhang, Dingyuan

    2015-03-04

    Uranyl (UO2 2+) is a form of uranium in aqueous solution that represents the greatest risk to human health because of its bioavailability. Different sensing techniques have been used with very sensitive detection limits especially the recently reported uranyl-specific DNAzymes systems. However, to the best of our knowledge, few efficient detection methods have been reported for uranyl sensing in seawater. Herein, gold nanoclusters (AuNCs) are employed in an efficient spectroscopic method to detect uranyl ion (UO2 2+) with a detection limit of 1.86 ÎM. In the absence of UO2 2+, the BSA-stabilized AuNCs (BSA-AuNCs) showed an intrinsic peroxidase-like activity. In the presence of UO2 2+, this activity can be efficiently restrained. The preliminary quenching mechanism and selectivity of UO2 2+ was also investigated and compared with other ions. This design strategy could be useful in understanding the binding affinity of protein-stabilized AuNCs to UO2 2+ and consequently prompt the recycling of UO2 2+ from seawater.

  10. Vibrio cholerae Detection in Water and Wastewater by Polymerase Chain Reaction Assay

    Directory of Open Access Journals (Sweden)

    Behnaz Barzamini

    2014-11-01

    Full Text Available Background: Vibrio cholerae is a significant human pathogen worldwide and annually causes some cases of deaths. Contaminated water plays an important role in transmission of this pathogen, which indicates the importance of early diagnosis. Objectives: The current study aimed to perform Polymerase Chain Reaction (PCR on water and wastewater samples to determine the detection limit for Vibrio cholerae. Materials and Methods: PCR was performed on the DNA extracted from Vibrio cholerae of the contaminated water and wastewater using ctxA gene specific primers. The accuracy of PCR method to detect these bacteria was also assessed. Results: The result of PCR performed on the extracted DNA showed a specific 241 base pair band. The limit of bacterial detection for water and wastewater were 40 cfu/mL and 81 cfu/mL, respectively. Conclusions: In the current study, PCR performance using the ctxA gene specific primers to detect Vibrio cholerae was found highly accurate and specific.

  11. SWEET CubeSat - Water detection and water quality monitoring for the 21st century

    Science.gov (United States)

    Antonini, Kelly; Langer, Martin; Farid, Ahmed; Walter, Ulrich

    2017-11-01

    Water scarcity and contamination of clean water have been identified as major challenges of the 21st century, in particular for developing countries. According to the International Water Management Institute, about 30% of the world's population does not have reliable access to clean water. Consequently, contaminated water contributes to the death of about 3 million people every year, mostly children. Access to potable water has been proven to boost education, equality and health, reduce hunger, as well as help the economy of the developing world. Currently used in-situ water monitoring techniques are sparse, and often difficult to execute. Space-based instruments will help to overcome these challenges by providing means for water level and water quality monitoring of medium-to-large sweet (fresh) water reservoirs. Data from hyperspectral imaging instruments on past and present governmental missions, such as Envisat and Aqua, has been used for this purpose. However, the high cost of large multi-purpose space vessels, and the lack of dedicated missions limits the continuous monitoring of inland and coastal water quality. The proposed CubeSat mission SWEET (Sweet Water Earth Education Technologies) will try to fill this gap. The SWEET concept is a joint effort between the Technical University of Munich, the German Space Operations Center and the African Steering Committee of the IAF. By using a novel Fabry-Perot interferometer-based hyperspectral imager, the mission will deliver critical data directly to national water resource centers in Africa with an unmatched cost per pixel ratio and high temporal resolution. Additionally, SWEET will incorporate education of students in CubeSat design and water management. Although the aim of the mission is to deliver local water quality and water level data to African countries, further coverage could be achieved with subsequent satellites. Finally, a constellation of SWEET-like CubeSats would extend the coverage to the whole

  12. Vacuum decay container closure integrity leak test method development and validation for a lyophilized product-package system.

    Science.gov (United States)

    Patel, Jayshree; Mulhall, Brian; Wolf, Heinz; Klohr, Steven; Guazzo, Dana Morton

    2011-01-01

    A leak test performed according to ASTM F2338-09 Standard Test Method for Nondestructive Detection of Leaks in Packages by Vacuum Decay Method was developed and validated for container-closure integrity verification of a lyophilized product in a parenteral vial package system. This nondestructive leak test method is intended for use in manufacturing as an in-process package integrity check, and for testing product stored on stability in lieu of sterility tests. Method development and optimization challenge studies incorporated artificially defective packages representing a range of glass vial wall and sealing surface defects, as well as various elastomeric stopper defects. Method validation required 3 days of random-order replicate testing of a test sample population of negative-control, no-defect packages and positive-control, with-defect packages. Positive-control packages were prepared using vials each with a single hole laser-drilled through the glass vial wall. Hole creation and hole size certification was performed by Lenox Laser. Validation study results successfully demonstrated the vacuum decay leak test method's ability to accurately and reliably detect those packages with laser-drilled holes greater than or equal to approximately 5 μm in nominal diameter. All development and validation studies were performed at Whitehouse Analytical Laboratories in Whitehouse, NJ, under the direction of consultant Dana Guazzo of RxPax, LLC, using a VeriPac 455 Micro Leak Test System by Packaging Technologies & Inspection (Tuckahoe, NY). Bristol Myers Squibb (New Brunswick, NJ) fully subsidized all work. A leak test performed according to ASTM F2338-09 Standard Test Method for Nondestructive Detection of Leaks in Packages by Vacuum Decay Method was developed and validated to detect defects in stoppered vial packages containing lyophilized product for injection. This nondestructive leak test method is intended for use in manufacturing as an in-process package integrity

  13. Intrinsic fiber optic sensor for distributed water detection

    Science.gov (United States)

    Lieberman, Robert A.; Mendoza, Edgar A.; Ferrell, Douglas J.; Schmidlin, Edward M.; Syracuse, Steven J.; Khalil, Albert N.; Dergevorkian, Ara; Sun, Zongjian; Gunther, Michael F.

    1994-03-01

    A distributed fiber optic moisture sensor based on intrinsic changes in the optical properties of the cladding is reported. A 10-meter-long fiber sensor was fabricated that demonstrated a response to humidity in less than 5 minutes. The humidity-sensitive cladding was fabricated on-line during fiber draw by continuously coating a multimode glass core fiber with a polyvinyl acetate cladding, in which a water-sensitive indicator had been dissolved. The indicator was a solvatochromic dye that showed a pronounced hypsochromic shift in its absorption spectrum in the presence of water. The moisture response of the sensor was monitored by measuring changes in the optical attenuation of the fiber in the region between 580 nm and 650 nm. This spectral region facilitates the use of commercially available solid state optoelectronic devices such as LEDs, laser diodes, and PIN photodiode detectors, in order to produce a low-cost, compact, lightweight humidity sensor.

  14. Arsenic detection in water: YPO4:Eu3+ nanoparticles

    Science.gov (United States)

    Ghosh, Debasish; Luwang, Meitram Niraj

    2015-12-01

    This work reports on the novel technique of detection of arsenic in aqueous solution utilising the luminescence properties of lanthanide doped nanomaterials. Eu3+ (5%) doped YPO4nanorodswere utilised for the said experiment. Co-precipitation method was used for the synthesis of the materials and characterised them with different instrumental techniques like X-ray diffraction (XRD), Infra-red (IR), UV-absorption, scanning electron microscope (SEM), transmission electron microscope (TEM), X-ray photoelectron spectroscopy (XPS) and photoluminescence studies. This nanoparticle can adsorb both arsenic and arsenious acids. We studied the effect of arsenic adsorption on the luminescence behaviour of the nanoparticles. Arsenic acid enhanced the luminescence intensity whereas arsenious acid quenched the luminescence. This luminescence enhancement or quenching is related with arsenic concentration. This relation of luminescence property with concentration of arsenic can be used to detect arsenic in industrial waste.

  15. Conformational basis for the Li(+)-induced leak current in the rat gamma-aminobutyric acid (GABA) transporter-1

    DEFF Research Database (Denmark)

    MacAulay, Nanna; Zeuthen, Thomas; Gether, Ulrik

    2002-01-01

    (+)-bound conformation of the protein displayed a lower passive water permeability than that of the Na(+)- and choline (Ch(+))-bound conformations and the leak current did not saturate with increasing amounts of Li(+) in the test solution. The mechanism that gives rise to the leak current did not support active water...... millimolar concentrations of Na(+) (the apparent affinity constant, K'(0.5) = 3 mM). In addition, it was found that the GABA transport current was sustained at correspondingly low Na(+) concentrations if Li(+) was present instead of choline. This is consistent with a model in which Li(+) can bind...

  16. Belgian experience in applying the {open_quotes}leak-before-break{close_quotes} concept to the primary loop piping

    Energy Technology Data Exchange (ETDEWEB)

    Gerard, R.; Malekian, C.; Meessen, O. [Tractebel Energy Engineering, Brussels (Belgium)

    1997-04-01

    The Leak Before Break (LBB) concept allows to eliminate from the design basis the double-ended guillotine break of the primary loop piping, provided it can be demonstrated by a fracture mechanics analysis that a through-wall flaw, of a size giving rise to a leakage still well detectable by the plant leak detection systems, remains stable even under accident conditions (including the Safe Shutdown Earthquake (SSE)). This concept was successfully applied to the primary loop piping of several Belgian Pressurized Water Reactor (PWR) units, operated by the Utility Electrabel. One of the main benefits is to permit justification of supports in the primary loop and justification of the integrity of the reactor pressure vessel and internals in case of a Loss Of Coolant Accident (LOCA) in stretch-out conditions. For two of the Belgian PWR units, the LBB approach also made it possible to reduce the number of large hydraulic snubbers installed on the primary coolant pumps. Last but not least, the LBB concept also facilitates the steam generator replacement operations, by eliminating the need for some pipe whip restraints located close to the steam generator. In addition to the U.S. regulatory requirements, the Belgian safety authorities impose additional requirements which are described in details in a separate paper. An novel aspect of the studies performed in Belgium is the way in which residual loads in the primary loop are taken into account. Such loads may result from displacements imposed to close the primary loop in a steam generator replacement operation, especially when it is performed using the {open_quote}two cuts{close_quotes} technique. The influence of such residual loads on the LBB margins is discussed in details and typical results are presented.

  17. Quantifying Urban Natural Gas Leaks from Street-level Methane Mapping: Measurements and Uncertainty

    Science.gov (United States)

    von Fischer, J. C.; Ham, J. M.; Griebenow, C.; Schumacher, R. S.; Salo, J.

    2013-12-01

    Leaks from the natural gas pipeline system are a significant source of anthropogenic methane in urban settings. Detecting and repairing these leaks will reduce the energy and carbon footprints of our cities. Gas leaks can be detected from spikes in street-level methane concentrations measured by analyzers deployed on vehicles. While a spike in methane concentration indicates a leak, an algorithm (e.g., inverse model) must be used to estimate the size of the leak (i.e., flux) from concentration data and supporting meteorological information. Unfortunately, this drive-by approach to leak quantification is confounded by the complexity of urban roughness, changing weather conditions, and other incidental factors (e.g., traffic, vehicle speed, etc.). Furthermore, the vehicle might only pass through the plume one to three times during routine mapping. The objective of this study was to conduct controlled release experiments to better quantify the relationship between mobile methane concentration measurements and the size and location of the emission source (e.g., pipeline leakage) in an urban environment. A portable system was developed that could release methane at known rates between 10 and 40 LPM while maintaining concentrations below the lower explosive limit. A mapping vehicle was configured with fast response methane analyzers, GPS, and meteorological instruments. Portable air-sampling tripods were fabricated that could be deployed at defined distances downwind from the release point and automatically-triggered to collect grab samples. The experimental protocol was as follows: (1) identify an appropriate release point within a city, (2) release methane at a known rate, (3) measure downwind street-level concentrations with the vehicle by making multiple passes through the plume, and (4) collect supporting concentration and meteorological data with the static tripod samplers deployed in the plume. Controlled release studies were performed at multiple locations and

  18. Detection of Hot Halo Gets Theory Out of Hot Water

    Science.gov (United States)

    2006-02-01

    Scientists using NASA's Chandra X-ray Observatory have detected an extensive halo of hot gas around a quiescent spiral galaxy. This discovery is evidence that galaxies like our Milky Way are still accumulating matter from the gradual inflow of intergalactic gas. "What we are likely witnessing here is the ongoing galaxy formation process," said Kristian Pedersen of the University of Copenhagen, Denmark, and lead author of a report on the discovery. Chandra observations show that the hot halo extends more than 60,000 light years on either side of the disk of the galaxy known as NGC 5746. The detection of such a large halo alleviates a long-standing problem for the theory of galaxy formation. Spiral galaxies are thought to form from enormous clouds of intergalactic gas that collapse to form giant, spinning disks of stars and gas. Chandra X-ray Image of NGC 5746 Chandra X-ray Image of NGC 5746 One prediction of this theory is that large spiral galaxies should be immersed in halos of hot gas left over from the galaxy formation process. Hot gas has been detected around spiral galaxies in which vigorous star formation is ejecting matter from the galaxy, but until now hot halos due to infall of intergalactic matter have not been detected. "Our observations solve the mystery of the missing hot halos around spiral galaxies," said Pedersen. "The halos exist, but are so faint that an extremely sensitive telescope such as Chandra is needed to detect them." DSS Optical Image of NGC 5746 DSS Optical Image of NGC 5746 NGC 5746 is a massive spiral galaxy about a 100 million light years from Earth. Its disk of stars and gas is viewed almost edge-on. The galaxy shows no signs of unusual star formation, or energetic activity from its nuclear region, making it unlikely that the hot halo is produced by gas flowing out of the galaxy. "We targeted NGC 5746 because we thought its distance and orientation would give us the best chance to detect a hot halo caused by the infall of

  19. Utilizing online monitoring of water wells for detecting earthquake precursors

    Science.gov (United States)

    Reuveni, Y.; Anker, Y.; Inbar, N.; Yellin-Dror, A.; Guttman, J.; Flexer, A.

    2015-12-01

    Groundwater reaction to earthquakes is well known and documented, mostly as changes in water levels or springs discharge, but also as changes in groundwater chemistry. During 2004 groundwater level undulations preceded a series of moderate (ML~5) earthquakes, which occurred along the Dead Sea Rift System (DSRS). In order to try and validate these preliminary observations monitoring of several observation wells was initiated. The monitoring and telemetry infrastructure as well as the wells were allocated specifically for the research by the Israeli National Water Company (Mekorot LTD.). Once several earthquake events were skipped due to insufficient sampling frequency and owing to insufficient storage capacity that caused loss of data, it was decided to establish an independent monitoring system. This current stage of research had commenced at 2011 and just recently became fully operative. At present there are four observation wells that are located along major faults, adjacent to the DSRS. The wells must be inactive and with a confined production layer. The wells are equipped with sensors for groundwter level, water conductivity and groundwater temperature measurements. The data acquisition and transfer resolution is of one minute and the dataset is being transferred through a GPRS network to a central database server. Since the start of the present research stage, most of the earthquakes recorded at the vicinity of the DSRS were smaller then ML 5, with groundwater response only after the ground movement. Nonetheless, distant earthquakes occurring as far as 300 km along a DSRS adjacent fault (ML~3), were noticed at the observation wells. A recent earthquake precursory reoccurrence was followed by a 5.5ML earthquake with an epicenter near the eastern shore of the Red Sea about 400km south to the wells that alerted the quake (see figure). In both wells anomalies is water levels and conductivity were found few hours before the quake, although any single anomaly cannot

  20. Transient electromagnetic detection method in water-sealed underground storage caverns

    Directory of Open Access Journals (Sweden)

    Fang Lin

    2016-09-01

    Full Text Available Taking advantage of the water sensitivity of the transient electromagnetic method (TEM, this study assesses the effectiveness of the water curtain system for underground LPG storage caverns during the excavation period. It also detects fracture water flow during the excavation process in light of the practice of two pilot large underground LPG storage caverns in China. Comparative maps of apparent resistivity derived from TEM measurements before and after water-filling during the excavation process have been discussed to improve the quality of the water curtain system. This is the first case to apply TEM to detect the quality of the water curtain system during the construction of underground LPG storage cavern projects, and it is found to be practical, more visualized and worth popularizing.

  1. A simple field test for the detection of faecal pollution in drinking water.

    Science.gov (United States)

    Manja, K S; Maurya, M S; Rao, K M

    1982-01-01

    A comprehensive field investigation in several parts of India has revealed that the presence of coliforms in drinking water is associated with hydrogen sulfide-producing organisms. This paper describes a simple, rapid, and inexpensive field test for the screening of drinking water for faecal pollution, based on the detection of hydrogen sulfide. The new test showed good agreement with the standard most probable number (MPN) test. It proved highly successful in the field when it was used to detect faecal pollution and to monitor water quality during an outbreak of water-borne hepatitis A infection in the city of Gwalior. The test is reliable and simple to perform, and will be especially useful for screening rural water supplies and for large-scale screening of urban water supplies where resources, time, manpower, and laboratory facilities are limited.

  2. Sensor to Detect Aqueous Film Forming Foam (AFFF) in Ship Bilge Water: Construction and Installation

    National Research Council Canada - National Science Library

    Kirts, Richard

    2001-01-01

    .... The primary use of the sensor is the detection of AFFF in the bilge water of Navy ships. If AFFF is present in bilge water off-loaded to a shore-side wastewater treatment plant, it may cause serious upsets in treatment plant operation...

  3. Impact of soil water content on landmine detection using radar and thermal infared sensors

    NARCIS (Netherlands)

    Hong, S.-H.; Miller, T.W.; Tobin, H.; Borchers, B.; Hendrickx, J.M.H.; Lensen, H.A.; Schwering, P.B.W.

    2001-01-01

    Land mines are a major problem in many areas of the world. In spite of the fact that many different types of land mines sensors have been developed, the detection of non-metallic land mines remains very difficult. Most landmine detection sensors are affected by soil properties such as water content,

  4. Contamination Event Detection with Multivariate Time-Series Data in Agricultural Water Monitoring

    Directory of Open Access Journals (Sweden)

    Yingchi Mao

    2017-12-01

    Full Text Available Time series data of multiple water quality parameters are obtained from the water sensor networks deployed in the agricultural water supply network. The accurate and efficient detection and warning of contamination events to prevent pollution from spreading is one of the most important issues when pollution occurs. In order to comprehensively reduce the event detection deviation, a spatial–temporal-based event detection approach with multivariate time-series data for water quality monitoring (M-STED was proposed. The M-STED approach includes three parts. The first part is that M-STED adopts a Rule K algorithm to select backbone nodes as the nodes in the CDS, and forward the sensed data of multiple water parameters. The second part is to determine the state of each backbone node with back propagation neural network models and the sequential Bayesian analysis in the current timestamp. The third part is to establish a spatial model with Bayesian networks to estimate the state of the backbones in the next timestamp and trace the “outlier” node to its neighborhoods to detect a contamination event. The experimental results indicate that the average detection rate is more than 80% with M-STED and the false detection rate is lower than 9%, respectively. The M-STED approach can improve the rate of detection by about 40% and reduce the false alarm rate by about 45%, compared with the event detection with a single water parameter algorithm, S-STED. Moreover, the proposed M-STED can exhibit better performance in terms of detection delay and scalability.

  5. Leaks in gas mains - Location using GIS and GPS; Leckstellen in Gasrohrnetzen. Aufspueren mit Unterstuetzung durch GIS und GPS

    Energy Technology Data Exchange (ETDEWEB)

    Huber, D.

    2009-07-01

    This article takes a look how leaks in gas mains can be located with the help of geographical information systems (GIS) and the satellite-based Global Positioning System (GPS). The advantages for long-term planning and, in future, maintenance work are stressed. Experienced gained by the IWB utility in Basel, Switzerland, is discussed. Here, a system for the monitoring and maintenance of the whole of the City of Basel's natural gas supply network is discussed. Cost savings and a particularly improved increase in the quality of leak detection work is noted. Modern technology using GPS-based equipment in the detection of leaks in the gas mains is reviewed. An example of the documentation of the gas mains in a GIS system is given.

  6. Dynamic Water Surface Detection Algorithm Applied on PROBA-V Multispectral Data

    Directory of Open Access Journals (Sweden)

    Luc Bertels

    2016-12-01

    Full Text Available Water body detection worldwide using spaceborne remote sensing is a challenging task. A global scale multi-temporal and multi-spectral image analysis method for water body detection was developed. The PROBA-V microsatellite has been fully operational since December 2013 and delivers daily near-global synthesis with a spatial resolution of 1 km and 333 m. The Red, Near-InfRared (NIR and Short Wave InfRared (SWIR bands of the atmospherically corrected 10-day synthesis images are first Hue, Saturation and Value (HSV color transformed and subsequently used in a decision tree classification for water body detection. To minimize commission errors four additional data layers are used: the Normalized Difference Vegetation Index (NDVI, Water Body Potential Mask (WBPM, Permanent Glacier Mask (PGM and Volcanic Soil Mask (VSM. Threshold values on the hue and value bands, expressed by a parabolic function, are used to detect the water bodies. Beside the water bodies layer, a quality layer, based on the water bodies occurrences, is available in the output product. The performance of the Water Bodies Detection Algorithm (WBDA was assessed using Landsat 8 scenes over 15 regions selected worldwide. A mean Commission Error (CE of 1.5% was obtained while a mean Omission Error (OE of 15.4% was obtained for minimum Water Surface Ratio (WSR = 0.5 and drops to 9.8% for minimum WSR = 0.6. Here, WSR is defined as the fraction of the PROBA-V pixel covered by water as derived from high spatial resolution images, e.g., Landsat 8. Both the CE = 1.5% and OE = 9.8% (WSR = 0.6 fall within the user requirements of 15%. The WBDA is fully operational in the Copernicus Global Land Service and products are freely available.

  7. Nanochannel-based electrochemical sensor for the detection of pharmaceutical contaminants in water.

    Science.gov (United States)

    Nagaraj, Vinay J; Jacobs, Michael; Vattipalli, Krishna Mohan; Annam, Venkata Praveen; Prasad, Shalini

    2014-01-01

    Effective real-time monitoring is the key to understanding and tackling the issue of pharmaceutical contamination of water. This research demonstrates the utility of an alumina nanochannel-based electrochemical sensor platform for the detection of ibuprofen in water derived from various sources. Our results indicate that the sensor is highly sensitive with a limit of detection at 0.25 pg mL(-1). The novel sensor described here has potential for application as a simple, rapid, inexpensive and highly reliable method for real-time environmental water quality assessment.

  8. Detection and persistence of fecal Bacteroidales as water quality indicators in unchlorinated drinking water

    DEFF Research Database (Denmark)

    Saunders, Aaron Marc; Kristiansen, Anja; Lund, Marie Braad

    2009-01-01

    doi:10.1016/j.syapm.2008.11.004 The results of this study support the use of fecal Bacteroidales qPCR as a rapid method to complement traditional, culture dependent, water quality indicators in systems where drinking water is supplied without chlorination or other forms of disinfection. A SYBR...... green based, quantitative PCR assay was developed to determine the concentration of fecal Bacteroidales 16S rRNA gene copies. The persistence of a Bacteroides vulgatus pure culture and fecal Bacteroidales from a wastewater inoculum was determined in unchlorinated drinking water at10°C. B. vulgatus 16S r......RNA gene copies persisted throughout the experimental period (200 days) in sterile drinking water but decayed faster in natural drinking water, indicating that the natural microbiota accelerated decay. In a simulated fecal contamination of unchlorinated drinking water, the decay of fecal Bacteroidales 16S...

  9. Quantitative PCR and Digital PCR for Detection of Ascaris lumbricoides Eggs in Reclaimed Water

    Directory of Open Access Journals (Sweden)

    Lucrecia Acosta Soto

    2017-01-01

    Full Text Available The reuse of reclaimed water from wastewater depuration is a widespread and necessary practice in many areas around the world and must be accompanied by adequate and continuous quality control. Ascaris lumbricoides is one of the soil-transmitted helminths (STH with risk for humans due to its high infectivity and an important determinant of transmission is the inadequacy of water supplies and sanitation. The World Health Organization (WHO recommends a limit equal to or lower than one parasitic helminth egg per liter, to reuse reclaimed water for unrestricted irrigation. We present two new protocols of DNA extraction from large volumes of reclaimed water. Quantitative PCR (qPCR and digital PCR (dPCR were able to detect low amounts of A. lumbricoides eggs. By using the first extraction protocol, which processes 500 mL of reclaimed water, qPCR can detect DNA concentrations as low as one A. lumbricoides egg equivalent, while dPCR can detect DNA concentrations as low as five A. lumbricoides egg equivalents. By using the second protocol, which processes 10 L of reclaimed water, qPCR was able to detect DNA concentrations equivalent to 20 A. lumbricoides eggs. This fact indicated the importance of developing new methodologies to detect helminth eggs with higher sensitivity and precision avoiding possible human infection risks.

  10. 40 CFR 63.1363 - Standards for equipment leaks.

    Science.gov (United States)

    2010-07-01

    ... definition. The instrument reading, as determined by the method as specified in § 63.180(b) of subpart H of... equipment leaks. (a) General equipment leak requirements. (1) The provisions of this section apply to... subpart applies to general alternative means of emission limitation. Section 63.179 of subpart H of this...

  11. Detection of water contamination from hydraulic fracturing wastewater: a μPAD for bromide analysis in natural waters.

    Science.gov (United States)

    Loh, Leslie J; Bandara, Gayan C; Weber, Genevieve L; Remcho, Vincent T

    2015-08-21

    Due to the rapid expansion in hydraulic fracturing (fracking), there is a need for robust, portable and specific water analysis techniques. Early detection of contamination is crucial for the prevention of lasting environmental damage. Bromide can potentially function as an early indicator of water contamination by fracking waste, because there is a high concentration of bromide ions in fracking wastewaters. To facilitate this, a microfluidic paper-based analytical device (μPAD) has been developed and optimized for the quantitative colorimetric detection of bromide in water using a smartphone. A paper microfluidic platform offers the advantages of inexpensive fabrication, elimination of unstable wet reagents, portability and high adaptability for widespread distribution. These features make this assay an attractive option for a new field test for on-site determination of bromide.

  12. Development of the Noise-Resistant and Sound Focusing Accessory of Ultrasonic Leak Detector for Spacecraft on Orbit

    Science.gov (United States)

    Sun, W.; Yan, R. X.; Sun, L. C.; Shao, R. P.

    2017-12-01

    Ultrasonic signal produced by the gas leak is so week that it is difficult to detect, and easily interfered. So developing the noise-resistant and sound focusing accessory for the ultrasonic leak detector is very important for improving ultrasonic leak detector sensitivity and noise-resistant capability. Based on the theory analysis of the leak ultrasonic signal reverberation and anacampsis, the 5A06 aluminium alloy and nylon were selected as the material of noise-resistant and sound focusing accessory by calculation and compare. Then the circular cone trumpet structure was design as the accessory main structure, and the nylon expansion port, nylon shrinking port and aluminium alloy expansion port structures were manufactured. The different structure characters were shown by the contrasting experiment. The results indicate that the nylon expansion circular cone trumpet structure has better sound focusing performance and it can improve the testing sound pressure amplitude 10 bigger than the detector without the accessory. And the aluminium alloy expansion circular cone trumpet structure has better noise-resistant ability than others. These conclusions are very important for the spacecraft leak detection and it can provide some references for the design of the noise-resistant and sound focusing structure.

  13. New leak assembly based on fluidic nanochannels

    Energy Technology Data Exchange (ETDEWEB)

    Zhu, Aiqing; Zhao, Yongheng; Wang, Xudi, E-mail: wxudi@hfut.edu.cn [School of Mechanical and Automobile Engineering, Hefei University of Technology, Hefei 230031 (China); Wang, Yu; Wei, Wei; Qiu, Keqiang [National Synchrotron Radiation Laboratory, University of Science and Technology of China, Hefei 230029 (China); Dong, Dong [Shanghai Institute of Spacecraft Equipment, Shanghai 201100 (China)

    2016-09-15

    Fluidic nanochannels with a characteristic dimension of ∼280 nm were fabricated and designed as a leak assembly, where the nanochannels were formed on silicon wafers and enclosed with Pyrex{sup ®} glass. The geometric dimensions were characterized by scanning electron microscopy, and the gas flow conductance of He and other heavy gases (N{sub 2}, O{sub 2}, and Ar) was measured, and its uncertainty estimated, by the difference method. The results indicated that the measured flow conductance values were 45% less than the calculated flow conductance values. For helium, molecular flow was shown to occur at pressures ranging from vacuum to atmospheric pressure. As a consequence of the well-defined geometry, the prediction of flow conductance could be achieved for various gas species.

  14. Confidence leak in perceptual decision-making

    Science.gov (United States)

    Rahnev, Dobromir; Koizumi, Ai; McCurdy, Li Yan; D’Esposito, Mark; Lau, Hakwan

    2015-01-01

    We live in a continuous environment in which the visual scene changes on a slow timescale. It has been shown that, to exploit such environmental stability, the brain creates a “continuity field” such that objects seen seconds ago influence the perception of current objects. What is unknown is whether a similar mechanism exists at the level of our metacognitive representations. In three experiments we demonstrate a robust inter-task “confidence leak” that cannot be explained by response priming or attentional fluctuations. Observers’ ability to modulate this confidence leak predicted higher capacity for metacognition as well as greater gray matter volume in the prefrontal cortex. A model based on normative principles from Bayesian inference explained the results by postulating that observers subjectively estimate the perceptual signal strength in a stable environment. These results point to the existence of a novel metacognitive mechanism mediated by regions in prefrontal cortex. PMID:26408037

  15. Pressure Change Measurement Leak Testing Errors

    Energy Technology Data Exchange (ETDEWEB)

    Pryor, Jeff M [ORNL; Walker, William C [ORNL

    2014-01-01

    A pressure change test is a common leak testing method used in construction and Non-Destructive Examination (NDE). The test is known as being a fast, simple, and easy to apply evaluation method. While this method may be fairly quick to conduct and require simple instrumentation, the engineering behind this type of test is more complex than is apparent on the surface. This paper intends to discuss some of the more common errors made during the application of a pressure change test and give the test engineer insight into how to correctly compensate for these factors. The principals discussed here apply to ideal gases such as air or other monoatomic or diatomic gasses; however these same principals can be applied to polyatomic gasses or liquid flow rate with altered formula specific to those types of tests using the same methodology.

  16. QUANTITATIVE VS. CONVENTIONAL PCR FOR DETECTION OF HUMAN ADENOVIRUSES IN WATER AND SEDIMENT SAMPLES

    Directory of Open Access Journals (Sweden)

    Rodrigo STAGGEMEIER

    2015-08-01

    Full Text Available SUMMARY Human Adenoviruses (HAdV are notably resistant in the environment. These agents may serve as effective indicators of fecal contamination, and may act as causative agents of a number of different diseases in human beings. Conventional polymerase chain reaction (PCR and, more recently, quantitative PCR (qPCR are widely used for detection of viral agents in environmental matrices. In the present study PCR and SYBR(rGreen qPCR assays were compared for detection of HAdV in water (55 and sediments (20 samples of spring and artesian wells, ponds and streams, collected from dairy farms. By the quantitative methodology HAdV were detected in 87.3% of the water samples and 80% of the sediments, while by the conventional PCR 47.3% and 35% were detected in water samples and sediments, respectively.

  17. Detection of Flavobacterium psychrophilum from fish tissue and water samples by PCR amplification

    DEFF Research Database (Denmark)

    Wiklund, T.; Madsen, Lone; Bruun, Morten Sichlau

    2000-01-01

    investigation, the possible detection of Fl. psychrophilum from fish tissue and water samples was examined using nested PCR with DNA probes against a sequence of the 16S rRNA genes. The DNA was extracted using Chelex(R) 100 chelating resin. The primers, which were tested against strains isolated from diseased......-assay detected Fl. psychrophilum in water samples taken from a rainbow trout farm, but Fl. psychrophilum could not be isolated using inoculation on selective agar. The method presented here has the potential to detect low levels of Fl. psychrophilum in fish tissue and in water samples, and the technique can...... fish, healthy fish, fish farm environments and reference strains, proved to be specific for Fl. psychrophilum. The obtained detection limit of Fl. psychrophilum seeded into rainbow trout brain tissue was 0.4 cfu in the PCR tube, corresponding to 17 cfu mg(-1) brain tissue. The PCR-assay proved...

  18. Comparison of PCR with Standard Method (MPN for detection of bacterial contamination in drinking water

    Directory of Open Access Journals (Sweden)

    Fatemeh Dehghan

    2014-11-01

    Full Text Available Background: Detection of bacterial contamination in drinking water by culture method is a time and cost consuming method and spends a few days depending on contamination degree. However, the people use the tap water during that time. Molecular methods are rapid and sensitive. In this study a rapid Multiplex PCR method was used for rapid analysis both coliform bacteria and E.coli, and probable detection of VBNC bacteria in drinking water, the experiments were performed in bacteriological lab of water and Wastewater Corporation in Markazi province. Material and Methods:Amplification of a fragment from each of lacZ and uidA genes in a Multiplex PCR was used for detection of coliforms. Eight samples was taken from Arak drinking water system including 36 samples of wells, 41 samples of water distribution network and 3 samples from water storages were examined by amplification of lacZ and uidA genes in a Multiplex PCR. Equivalently, the MPN test was applied as a standard method for all samples for comparison of results. Standard bacteria, pure bacteria isolated from positive MPN and CRM were examined by PCR and MPN method. Results: The result of most samples water network, water storages, and water well were same in both MPN and PCR method .The results of standard bacteria and pure cultures of bacteria isolated from positive MPN and CRM confirmed the PCR method. Five samples were positive in PCR but negative in MPN method. Duration time of PCR was decreased about 105 min by changing the PCR program and electrophoreses factors. Conclusion: The Multiplex PCR can detect coliform bacteria and E.coli synchronous in drinking water.

  19. Human risk assessment of benzene after a gasoline station fuel leak

    Directory of Open Access Journals (Sweden)

    Miriam dos Anjos Santos

    2013-06-01

    Full Text Available OBJECTIVE: To assess the health risk of exposure to benzene for a community affected by a fuel leak. METHODS: Data regarding the fuel leak accident with, which occurred in the Brasilia, Federal District, were obtained from the Fuel Distributor reports provided to the environmental authority. Information about the affected population (22 individuals was obtained from focal groups of eight individuals. Length of exposure and water benzene concentration were estimated through a groundwater flow model associated with a benzene propagation model. The risk assessment was conducted according to the Agency for Toxic Substances and Disease Registry methodology. RESULTS: A high risk perception related to the health consequences of the accident was evident in the affected community (22 individuals, probably due to the lack of assistance and a poor risk communication from government authorities and the polluting agent. The community had been exposed to unsafe levels of benzene (> 5 µg/L since December 2001, five months before they reported the leak. The mean benzene level in drinking water (72.2 µg/L was higher than that obtained by the Fuel Distributer using the Risk Based Corrective Action methodology (17.2 µg/L.The estimated benzene intake from the consumption of water and food reached a maximum of 0.0091 µg/kg bw/day (5 x 10-7 cancer risk per 106 individuals. The level of benzene in water vapor while showering reached 7.5 µg/m3 for children (1 per 104 cancer risk. Total cancer risk ranged from 110 to 200 per 106 individuals. CONCLUSIONS: The population affected by the fuel leak was exposed to benzene levels that might have represented a health risk. Local government authorities need to develop better strategies to respond rapidly to these types of accidents to protect the health of the affected population and the environment.

  20. Suitability of Optical, Physical and Chemical Measurements for Detection of Changes in Bacterial Drinking Water Quality

    Science.gov (United States)

    Ikonen, Jenni; Pitkänen, Tarja; Miettinen, Ilkka T.

    2013-01-01

    In this study, different optical, physical and chemical measurements were tested for their capacity to detect changes in water quality. The tests included UV-absorbance at 254 nm, absorbance at 420 nm, turbidity, particle counting, temperature, pH, electric conductivity (EC), free chlorine concentration and ATP concentration measurements. Special emphasis was given to investigating the potential for measurement tools to detect changes in bacterial concentrations in drinking water. Bacterial colony counts (CFU) and total bacterial cell counts (TBC) were used as reference methods for assessing the bacterial water quality. The study consists of a series of laboratory scale experiments: monitoring of regrowth of Pseudomonas fluorescens, estimation of the detection limits for optical measurements using Escherichia coli dilutions, verification of the relationships by analysing grab water samples from various distribution systems and utilisation of the measurements in the case of an accidentally contaminated distribution network. We found significant correlations between the tested measurements and the bacterial water quality. As the bacterial contamination of water often co-occurs with the intrusion of matrixes containing mainly non-bacterial components, the tested measurement tools can be considered to have the potential to rapidly detect any major changes in drinking water quality. PMID:24284353

  1. Suitability of optical, physical and chemical measurements for detection of changes in bacterial drinking water quality.

    Science.gov (United States)

    Ikonen, Jenni; Pitkänen, Tarja; Miettinen, Ilkka T

    2013-10-25

    In this study, different optical, physical and chemical measurements were tested for their capacity to detect changes in water quality. The tests included UV-absorbance at 254 nm, absorbance at 420 nm, turbidity, particle counting, temperature, pH, electric conductivity (EC), free chlorine concentration and ATP concentration measurements. Special emphasis was given to investigating the potential for measurement tools to detect changes in bacterial concentrations in drinking water. Bacterial colony counts (CFU) and total bacterial cell counts (TBC) were used as reference methods for assessing the bacterial water quality. The study consists of a series of laboratory scale experiments: monitoring of regrowth of Pseudomonas fluorescens, estimation of the detection limits for optical measurements using Escherichia coli dilutions, verification of the relationships by analysing grab water samples from various distribution systems and utilisation of the measurements in the case of an accidentally contaminated distribution network. We found significant correlations between the tested measurements and the bacterial water quality. As the bacterial contamination of water often co-occurs with the intrusion of matrixes containing mainly non-bacterial components, the tested measurement tools can be considered to have the potential to rapidly detect any major changes in drinking water quality.

  2. Determination of Monochloroacetic Acid in Swimming Pool Water by Ion Chromatography-Conductivity Detection

    Directory of Open Access Journals (Sweden)

    Maria Pythias B. Espino

    2013-02-01

    Full Text Available In this study, an analytical method involving ion chromatography with conductivity detection was developed and optimized for the determination of monochloroacetic acid in swimming pool water. The ion chromatographic method has a detection limit of 0.02 mg L-1 and linear range of 0.05 to 1.0 mg L-1 with correlation coeff icient of 0.9992. The method is reproducible with percent RSD of 0.052% (n=10. The recovery of monochloroacetic acid spiked in different water types (bottled, tap and swimming pool water ranged from 28 to 122%. In dilute solutions, chloride and bromide were simultaneously analyzed along with monochloroacetic acid using the optimized method. Chloride and bromide have detection limits of 0.01 to 0.05 mg L-1, respectively. The usefulness of the ion chromatographic method was demonstrated in the analysis of monochloroacetic acid in swimming pool water samples. In such highly-chlorinated samples, an Ag/H cartridge was used prior to the ion chromatographic determination so as to minimize the signal due to chloride ion. Monochloroacetic acid was detected in concentrations between 0.020 and 0.093 mg L-1 in three of the six swimming pool water samples studied. The presence of monochloroacetic acid in the swimming pool water samples suggests the possible occurrence of other disinfection by-products in these waters.

  3. Sulphur hexafluoride gas detection

    CSIR Research Space (South Africa)

    Stolper, R

    2006-02-01

    Full Text Available This poster describes the development process of an electro-optical based solution for detecting and locating SF6 gas leaks at gas insulated switch gear. The principal technologies that were researched are explained with their advantages...

  4. Application of quantitative PCR for the detection of microorganisms in water.

    Science.gov (United States)

    Botes, Marelize; de Kwaadsteniet, Michéle; Cloete, Thomas Eugene

    2013-01-01

    The occurrence of microorganisms in water due to contamination is a health risk and control thereof is a necessity. Conventional detection methods may be misleading and do not provide rapid results allowing for immediate action. The quantitative polymerase chain reaction (qPCR) method has proven to be an effective tool to detect and quantify microorganisms in water within a few hours. Quantitative PCR assays have recently been developed for the detection of specific adeno- and polyomaviruses, bacteria and protozoa in different water sources. The technique is highly sensitive and able to detect low numbers of microorganisms. Quantitative PCR can be applied for microbial source tracking in water sources, to determine the efficiency of water and wastewater treatment plants and act as a tool for risk assessment. Different qPCR assays exist depending on whether an internal control is used or whether measurements are taken at the end of the PCR reaction (end-point qPCR) or in the exponential phase (real-time qPCR). Fluorescent probes are used in the PCR reaction to hybridise within the target sequence to generate a signal and, together with specialised systems, quantify the amount of PCR product. Quantitative reverse transcription polymerase chain reaction (q-RT-PCR) is a more sensitive technique that detects low copy number RNA and can be applied to detect, e.g. enteric viruses and viable microorganisms in water, and measure specific gene expression. There is, however, a need to standardise qPCR protocols if this technique is to be used as an analytical diagnostic tool for routine monitoring. This review focuses on the application of qPCR in the detection of microorganisms in water.

  5. Wet-aerosol leakage through simulated containment leak paths

    Energy Technology Data Exchange (ETDEWEB)

    Sutradhar, S.C. [Atomic Energy of Canada Limited, Chalk River, Ontario (Canada)

    2007-07-01

    Some types of postulated accidents in a nuclear reactor can result in the formation of radioactive wet aerosols in containment and their subsequent release into the environment. Wet-aerosol leakage was investigated using simulated leak paths for isolation damper valves and airlock door seals. Leakage was calculated from measured uranine concentrations deposited on high-quality filters positioned downstream of the simulated leak paths. Test results indicated that a small fraction of wet aerosols leaked through the simulated isolation damper valves, whereas a large fraction leaked through the simulated airlock door seals. Data on wet-aerosol leakage through containment leak paths are needed to develop and validate models in safety analysis codes. (author)

  6. Ecotoxicological risk assessment of chosen pharmaceuticals detected in surface waters.

    Science.gov (United States)

    Załęska-Radziwiłł, Monika; Affek, Katarzyna; Doskocz, Nina

    2017-11-10

    The goal of this work was to assess the risk posed by the presence of ciprofloxacin, 17α-ethinylestradiol and 5-fluorouracil in aquatic ecosystems based on chronic single-species ecotoxicological tests. There were 23 species used in this study: one cyanobacterium, three green algae, one higher plant, one protozoan, two crustaceans, two fish, 12 bacteria and one fungus (yeast). The risk assessment was performed on the basis of the PEC/PNEC ratio (PEC - predicted environmental concentration, PNEC - predicted no-effect concentration). PNEC was calculated using an assessment factor and statistical extrapolation models. The risk in relation to aquatic organisms proved to be high. The potentially affected fraction of aquatic species in the presence of pharmaceutical active ingredients, depending on the calculation method and the selected concentration in surface waters (predicted or measured), ranged from 6.26 to 27.84% for ciprofloxacin, 2.13 to 18.74% for 17α-ethinylestradiol and 4.96 to 39.28% for 5-fluorouracil. The study indicates several gaps in the existing guidelines, which may be considered within the guideline-revision process.

  7. Network hydraulics inclusion in water quality event detection using multiple sensor stations data.

    Science.gov (United States)

    Oliker, Nurit; Ostfeld, Avi

    2015-09-01

    Event detection is one of the current most challenging topics in water distribution systems analysis: how regular on-line hydraulic (e.g., pressure, flow) and water quality (e.g., pH, residual chlorine, turbidity) measurements at different network locations can be efficiently utilized to detect water quality contamination events. This study describes an integrated event detection model which combines multiple sensor stations data with network hydraulics. To date event detection modelling is likely limited to single sensor station location and dataset. Single sensor station models are detached from network hydraulics insights and as a result might be significantly exposed to false positive alarms. This work is aimed at decreasing this limitation through integrating local and spatial hydraulic data understanding into an event detection model. The spatial analysis complements the local event detection effort through discovering events with lower signatures by exploring the sensors mutual hydraulic influences. The unique contribution of this study is in incorporating hydraulic simulation information into the overall event detection process of spatially distributed sensors. The methodology is demonstrated on two example applications using base runs and sensitivity analyses. Results show a clear advantage of the suggested model over single-sensor event detection schemes. Copyright © 2015 Elsevier Ltd. All rights reserved.

  8. Highly sensitive detection of dipicolinic acid with a water-dispersible terbium-metal organic framework.

    Science.gov (United States)

    Bhardwaj, Neha; Bhardwaj, Sanjeev; Mehta, Jyotsana; Kim, Ki-Hyun; Deep, Akash

    2016-12-15

    The sensitive detection of dipicolinic acid (DPA) is strongly associated with the sensing of bacterial organisms in food and many types of environmental samples. To date, the demand for a sensitive detection method for bacterial toxicity has increased remarkably. Herein, we investigated the DPA detection potential of a water-dispersible terbium-metal organic framework (Tb-MOF) based on the fluorescence quenching mechanism. The Tb-MOF showed a highly sensitive ability to detect DPA at a limit of detection of 0.04nM (linear range of detection: 1nM to 5µM) and also offered enhanced selectivity from other commonly associated organic molecules. The present study provides a basis for the application of Tb-MOF for direct, convenient, highly sensitive, and specific detection of DPA in the actual samples. Copyright © 2016 Elsevier B.V. All rights reserved.

  9. A statistical analysis on the leak detection performance of ...

    Indian Academy of Sciences (India)

    Chinedu Duru

    2017-11-09

    Nov 9, 2017 ... Furthermore, with the inten- tional tampering of pipeline infrastructure on the increase, through terrorism and vandalism, the need for a reliable pipeline monitoring system is highly significant [3, 4]. Wireless sensor networks (WSNs) are just one of those technologies used in the remote monitoring of pipeline.

  10. Rapid Hydrogen and Methane Sensors for Wireless Leak Detection Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Under NASA STTR NNK07EA39C, ASR&D developed passive surface acoustic wave (SAW) based hydrogen sensors that utilize Pd nanocluster films on self-assembled...

  11. Detecting Canopy Water Status Using Shortwave Infrared Reflectance Data From Polar Orbiting and Geostationary Platforms

    DEFF Research Database (Denmark)

    Fensholt, Rasmus; Huber Gharib, Silvia; Proud, Simon Richard

    2010-01-01

    -based canopy water status detection from geostationary Meteosat Second Generation (MSG) Spinning Enhanced Visible and Infrared Imager (SEVIRI) data as compared to polar orbiting environmental satellite (POES)-based moderate resolution imaging spectroradiometer (MODIS) data. The EO-based SWIR water stress index...... observations from SEVIRI are furthermore sensitive to short-term variations of in situ measured plant water content indicators when aboveground biomass increases from 500 to 900 gm-2 (LAI ˜ 1-2). MODIS SIWSI observations in contrast do not covary with in situ measured moisture indicators. Spatio-temporal trend...... for SWIR-based canopy water status and stress monitoring in a semi-arid environment....

  12. River water quality analysis via headspace detection of volatile organic compounds

    Science.gov (United States)

    Tang, Johnny Jock Lee; Nishi, Phyllis Jacqueline; Chong, Gabriel Eng Wee; Wong, Martin Gideon; Chua, Hong Siang; Persaud, Krishna; Ng, Sing Muk

    2017-03-01

    Human civilization has intensified the interaction between the community and the environment. This increases the threat on the environm ent for being over exploited and contaminated with m anmade products and synthetic chemicals. Of all, clean water is one of the resources that can be easily contaminated since it is a universal solvent and of high mobility. This work reports the development and optimization of a water quality monitoring system based on metal oxide sensors. The system is intended to a ssist the detection of volatile organic compounds (VOCs) present in water sources online and onsite. The sampling mechanism was based on contactless mode, where headspace partial pressure of the VOCs formed above the water body in a close chamber was drawn for detection at the sensor platform. Pure toluene was used as standard to represent the broad spectrum of VOCs, and the sensor dynamic range was achieved from 1-1000 ppb. Several sensing parameters such as sampling time, headspace volume, and sensor recovery were s tudied and optimized. Besides direct detection of VOC contaminants in the water, the work has also been extended to detect VOCs produced by microbial communities and to c orrelate the size of the communities with the reading of V OCs recorded. This can serve to give b etter indication of water quality, not only on the conce ntration of VOCs c ontamination from chemicals, but also the content of microbes, which some can have severe effect on human health.

  13. New approaches for enhanced detection of enteroviruses from Hawaiian environmental waters.

    Directory of Open Access Journals (Sweden)

    Christina Connell

    Full Text Available Health risks associated with sewage-contaminated recreational waters are of important public health concern. Reliable water monitoring systems are therefore crucial. Current recreational water quality criteria rely predominantly on the enumeration of bacterial indicators, while potentially dangerous viral pathogens often remain undetected. Human enteric viruses have been proposed as alternative indicators; however, their detection is often hindered by low viral concentrations present in the environment. Reported here are novel and effective laboratory protocols for viral concentration and highly sensitive and optimized RT-PCR for the efficient detection of enteroviruses, an important enteric virus subset, in Hawaiian environmental waters. Eighteen published enterovirus primer pairs were comparatively evaluated for detection sensitivity. The primer set exhibiting the lowest detection limit under optimized conditions, EQ-1/EQ-2, was validated in a field survey of 22 recreational bodies of water located around the island of Oahu, Hawaii. Eleven sites tested positive for enterovirus, indicating fecal contamination at these locations. As an additional means of viral concentration, shellfish were collected from 9 sample sites and subjected to dissection, RNA extraction, and subsequent RT-PCR. Shellfish tissue from 6 of 9 sites tested positive for enterovirus. The techniques implemented here are valuable resources to aid accurate reflection of microbial contamination in Hawaii's environmental waters.

  14. An integrated logit model for contamination event detection in water distribution systems.

    Science.gov (United States)

    Housh, Mashor; Ostfeld, Avi

    2015-05-15

    The problem of contamination event detection in water distribution systems has become one of the most challenging research topics in water distribution systems analysis. Current attempts for event detection utilize a variety of approaches including statistical, heuristics, machine learning, and optimization methods. Several existing event detection systems share a common feature in which alarms are obtained separately for each of the water quality indicators. Unifying those single alarms from different indicators is usually performed by means of simple heuristics. A salient feature of the current developed approach is using a statistically oriented model for discrete choice prediction which is estimated using the maximum likelihood method for integrating the single alarms. The discrete choice model is jointly calibrated with other components of the event detection system framework in a training data set using genetic algorithms. The fusing process of each indicator probabilities, which is left out of focus in many existing event detection system models, is confirmed to be a crucial part of the system which could be modelled by exploiting a discrete choice model for improving its performance. The developed methodology is tested on real water quality data, showing improved performances in decreasing the number of false positive alarms and in its ability to detect events with higher probabilities, compared to previous studies. Copyright © 2015 Elsevier Ltd. All rights reserved.

  15. Plant viruses in aqueous environment - survival, water mediated transmission and detection.

    Science.gov (United States)

    Mehle, Nataša; Ravnikar, Maja

    2012-10-15

    The presence of plant viruses outside their plant host or insect vectors has not been studied intensively. This is due, in part, to the lack of effective detection methods that would enable their detection in difficult matrixes and in low titres, and support the search for unknown viruses. Recently, new and sensitive methods for detecting viruses have resulted in a deeper insight into plant virus movement through, and transmission between, plants. In this review, we have focused on plant viruses found in environmental waters and their detection. Infectious plant pathogenic viruses from at least 7 different genera have been found in aqueous environment. The majority of the plant pathogenic viruses so far recovered from environmental waters are very stable, they can infect plants via the roots without the aid of a vector and often have a wide host range. The release of such viruses from plants can lead to their dissemination in streams, lakes, and rivers, thereby ensuring the long-distance spread of viruses that otherwise, under natural conditions, would remain restricted to limited areas. The possible sources and survival of plant viruses in waters are therefore discussed. Due to the widespread use of hydroponic systems and intensive irrigation in horticulture, the review is focused on the possibility and importance of spreading viral infection by water, together with measures for preventing the spread of viruses. The development of new methods for detecting multiple plant viruses at the same time, like microarrays or new generation sequencing, will facilitate the monitoring of environmental waters and waters used for irrigation and in hydroponic systems. It is reasonable to expect that the list of plant viruses found in waters will thereby be expanded considerably. This will emphasize the need for further studies to determine the biological significance of water-mediated transport. Copyright © 2012 Elsevier Ltd. All rights reserved.

  16. Near-infrared hyperspectral imaging of water evaporation dynamics for early detection of incipient caries.

    Science.gov (United States)

    Usenik, Peter; Bürmen, Miran; Fidler, Aleš; Pernuš, Franjo; Likar, Boštjan

    2014-10-01

    Incipient caries is characterized as demineralization of the tooth enamel reflecting in increased porosity of enamel structure. As a result, the demineralized enamel may contain increased amount of water, and exhibit different water evaporation dynamics than the sound enamel. The objective of this paper is to assess the applicability of water evaporation dynamics of sound and demineralized enamel for detection and quantification of incipient caries using near-infrared hyperspectral imaging. The time lapse of water evaporation from enamel samples with artificial and natural caries lesions of different stages was imaged by a near-infrared hyperspectral imaging system. Partial least squares regression was used to predict the water content from the acquired spectra. The water evaporation dynamics was characterized by a first order logarithmic drying model. The calculated time constants of the logarithmic drying model were used as the discriminative feature. The conducted measurements showed that demineralized enamel contains more water and exhibits significantly faster water evaporation than the sound enamel. By appropriate modelling of the water evaporation process from the enamel surface, the contrast between the sound and demineralized enamel observed in the individual near infrared spectral images can be substantially enhanced. The presented results indicate that near-infrared based prediction of water content combined with an appropriate drying model presents a strong foundation for development of novel diagnostic tools for incipient caries detection. The results of the study enhance the understanding of the water evaporation process from the sound and demineralized enamel and have significant implications for the detection of incipient caries by near-infrared hyperspectral imaging. Copyright © 2014 Elsevier Ltd. All rights reserved.

  17. Comparison of filtering methods, filter processing and DNA extraction kits for detection of mycobacteria in water

    Directory of Open Access Journals (Sweden)

    Marija Kaevska

    2015-09-01

    Full Text Available Introduction and objective. Mycobacteria have been isolated from almost all types of natural waters, as well as from man-made water distribution systems. Detection of mycobacteria using PCR has been described in different types of water; however, currently, there is no standardised protocol for the processing of large volumes of water. Material and Methods. In the present study, different filtering methods are tested and optimised for tap or river water filtration up to 10 L, as well as filter processing and DNA isolation using four commercially available kits. Results. The PowerWater DNA isolation kit (MoBio, USA, together with a kit used for soil and other environmental samples (PowerSoil DNA isolation kit, MoBio, had the highest efficiency. Filtration of 10 L of water and elution of the filter in PBS with the addition of 0.05% of Tween 80 is suggested. Conclusions. The described protocol for filter elution is recommended, and the use of the PowerWater DNA isolation kit for the highest mycobacterial DNA yield from water samples. The described protocol is suitable for parallel detection of mycobacteria using cultivation.

  18. In-a-day electrochemical detection of coliforms in drinking water using a tyrosinase composite biosensor.

    Science.gov (United States)

    Serra, Beatriz; Morales, M Dolores; Zhang, Jinbiao; Reviejo, A Julio; Hall, Elizabeth H; Pingarron, Jose M

    2005-12-15

    A rapid method for the detection of fecal contamination in water based on the use of a tyrosinase composite biosensor for improved amperometric detection of beta-galactosidase activity is reported. The method relies on the detection of phenol released after the hydrolysis of phenyl beta-D-galactopyranoside (PG) by beta-galactosidase. Under the optimized PG concentration and pH (4.0) values, a detection limit of 1.2x10(-3) unit of beta-galactosidase/mL-1 was obtained. The capability of the sensor for the detection of Escherichia coli was evaluated using polymyxin B sulfate to allow permeabilization of the bacteria membrane. A detection limit of 1x10(6) cfu of E. coli mL-1 was obtained with no preconcentration or pre-enrichment steps. To improve the analytical characteristics for bacteria detection, the processes involving galactosidase induction during incubation and membrane permeabilization were optimized. Using 0.25 mM isopropyl beta-D-thiogalactopyranoside for the enzyme activity induction, and 10 microg mL-1 polymyxin B sulfate as permeabilizer agent, it was possible to detect bacteria concentrations as low as 10 cfu mL-1 after 5 h of enrichment. The possibility of detecting E. coli at the required levels for drinking water quality assessment (1 cfu/100 mL) is demonstrated, the time of analysis being shorter than 6.5 h and involving a simple methodology.

  19. Electrochemical detection of benzo(a)pyrene in acetonitrile-water binary medium.

    Science.gov (United States)

    Du, Chunyan; Hu, Yaqi; Li, Yunchao; Fan, Louzhen; Li, Xiaohong

    2015-06-01

    Electrochemical oxidation of adsorbed benzo(a)pyrene (BaP) on the glassy carbon electrode (GCE) was explored in acetonitrile-water. When the GCE was incubated in 100 nM BaP acetonitrile-water (V(water):V(acetonitrile)=1:1) for 10 min at open circuit, and then transferred into blank acetonitrile-water (V(water):V(acetonitrile)=1:1, pH= 0.70) for differential pulse voltammetry measurement, a distinct oxidation peak at 0.98 V (vs. Ag/AgCl) was observed. The peak potential was about 180 mV lower than that in acetonitrile. Importantly, the peak current was more than 22 times greater. The effects of water on BaP preconcentration on the electrode and electrochemical oxidation were revealed, respectively. Based on the results, an electrochemical assay for BaP detection was developed. The GCE was respectively incubated in acetonitrile-water (V(water):V(acetonitrile)=1:1)with BaP concentration ranged from 0 nM to 1000 nM, and then transferred into the corresponding blank acetonitrile-water (pH= 0.70) for DPV measurements. When the BaP concentration was increased, an increased oxidative current at 0.98 V (vs. Ag/AgCl) was observed, and a detection limit of 0.67 nM was achieved. Because all other priority polycyclic aromatic hydrocarbons could not be electrochemically oxidized at 0.98 V, the electrochemical assay showed very high selectivity to BaP. Finally, the developed electrochemical assay was successfully applied to determination of BaP in a series of real world samples, such as drinking water, tap water, lake water and river water. Copyright © 2015 Elsevier B.V. All rights reserved.

  20. DETECTION OF WATER SURFACES IN FULL-WAVEFORM LASER SCANNING DATA

    Directory of Open Access Journals (Sweden)

    A. Schmidt

    2012-09-01

    Full Text Available Airborne laser scanning has become a standard method for recording topographic data. A new generation of laser scanners digitises the complete waveform of the backscattered signal and thus offers the possibility of analysing the signal shape. As a product of the laser scanning, a digital surface model (DSM or a digital terrain model (DTM can be derived. In water regions, data acquisition by laser scanning is limited to the water surface because the near-infrared laser pulses hardly penetrate water. Therefore, a height model generated from laser scanner point clouds over water regions does not represent the actual terrain. The generation of a DTM thus requires the detection of water surfaces. In this study, a method for the detection and classification of water surfaces in airborne laser scanning data is proposed. The method works with both geometrical features (e.g. height or height variation and characteristics of the pulses derived from the full waveform of the returned signal (e.g. intensity or pulse width. In our strategy, based on fuzzy logic, all classification parameters are derived automatically from training areas. According to their statistical distributions, the features are considered with individual weights. The aim of this paper is to analyse crucial features for classification and to investigate the potential of full waveform laser scanning data for this application. We present results from different areas with lakes and rivers, analysing the contribution of the individual groups of features for the detection of water surfaces.

  1. [Determination of trace bromate in drinking water by ion chromatography with suppressed conductivity detection].

    Science.gov (United States)

    Ying, Bo; Li, Shumin; Yue, Yinling; Xueli, E

    2006-05-01

    Bromate is a common disinfection by-product produced from the ozonation of source water containing bromide. An ion exchange chromatographic method with suppressed conductivity detection for the determination of trace bromate in drinking water was developed. The separation of the bromate in drinking water was achieved on a Metrosep A Supp 5 anion exchange column and a Metrosep A Supp 4/5 Guard column with a carbonate eluent. A new dual suppressed system, an MSM II chemical suppressor combined with a CO2 suppressor, was used to suppress the background conductivity, and to improve the detection limit of bromate. Ion chromatographic experiments were carried out by using a Metrosep A Supp 5 anion exchange column with a suppressed conductivity detector and an eluent of 3.2 mmoL/L Na2CO3-1.0 mmol/L NaHCO3 at a flow rate of 0.65 mL/min. This method had good linearity (r = 0.9999) in the range of 5-100 microg/L and high precision (relative standard deviation (RSD) water, pure water and mineral water were 96.1%-107%, and the detection limit for bromate was 0.50 microg/L. This method has a simple operation procedure, good separation results, high sensitivity and good repeatability. It can be used as a standard method for the determination of bromate in drinking water.

  2. Alexandrite lidar for the atmospheric water vapor detection and development of powerful tunable sources in IR

    Science.gov (United States)

    Uchiumi, M.; Maeda, M.; Muraoka, K.; Uchino, O.

    1992-01-01

    New tunable solid-state lasers, such as alexandrite and Ti-sapphire lasers, provide a powerful technique to detect various molecules in the atmosphere whose absorption bands are in the infrared region. The differential absorption lidar (DIAL) system to measure the tropospheric water vapor has been investigated by many authors, in an early stage, by dye and ruby lasers. Using the alpha band of water vapor, the longest detection range can be obtained with high accuracy, and the alexandrite laser is the most suitable laser for this purpose. In this paper, we describe the detection of water vapor in the atmosphere by an alexandrite lidar, and the development of powerful tunable sources based on Raman lasers in the infrared region.

  3. [Review on characteristics and detecting assay of bacterial endotoxin contamination in water environment].

    Science.gov (United States)

    Zhang, Can; Liu, Wen-Jun; Zhang, Ming-Lu; Tian, Fang; Yang, Yi; An, Dai-Zhi

    2014-04-01

    Endotoxins, also known as lipopolysaccharide complexes, are anchored in the outer membrane cell wall of most Gram-negative bacteria and some cyanobacteria. They are continuously released to environment during cell decay. Being common pyrogens and highly immunogenic molecules, endotoxins are related to many human diseases. Due to the tolerances and thermo-stability of endotoxin molecules, they were hard to be removed by common methods. The health risk caused by the endotoxin contamination in drinking water and water environment by various exposure pathways have attracted more and more attention in recent years. In this paper, the physical and chemical properties, biological activities and detection assay of the endotoxin contamination were reviewed, and interfere factors of the main assay, the LAL/TAL (Limulus amebocyte lysate/Tachypleus amebocyte lysate) assay, for detecting endotoxin in water sample were investigated, and the development tendency of the endotoxin detection assay was analyzed.

  4. Detection of copper in water using on-line plasma-excited atomic absorption spectroscopy (AAS).

    Science.gov (United States)

    Porento, Mika; Sutinen, Veijo; Julku, Timo; Oikari, Risto

    2011-06-01

    A measurement method and apparatus was developed to measure continuously toxic metal compounds in industrial water samples. The method was demonstrated by using copper as a sample metal. Water was injected into the sample line and subsequently into a nitrogen plasma jet, in which the samples comprising the metal compound dissolved in water were decomposed. The transmitted monochromatic light was detected and the absorbance caused by copper atoms was measured. The absorbance and metal concentration were used to calculate sensitivity and detection limits for the studied metal. The sensitivity, limit of detection, and quantification for copper were 0.45 ± 0.02, 0.25 ± 0.01, and 0.85 ± 0.04 ppm, respectively.

  5. Extraperitoneal urine leak after renal transplantation: the role of radionuclide imaging and the value of accompanying SPECT/CT - a case report

    Directory of Open Access Journals (Sweden)

    Kostakoglu Lale

    2010-10-01

    Full Text Available Abstract Background The differentiation of the nature of a fluid collection as a complication of kidney transplantation is important for management and treatment planning. Early and delayed radionuclide renography can play an important role in the evaluation of a urine leak. However, it is sometimes limited in the evaluation of the exact location and extent of a urine leak. Case Presentation A 71-year-old male who had sudden anuria, scrotal swelling and elevated creatinine level after cadaveric renal transplantation performed Tc-99 m MAG3 renography to evaluate the renal function, followed by an ultrasound which was unremarkable. An extensive urine leak was evident on the planar images. However, an exact location of the urine leak was unknown. Accompanying SPECT/CT images confirmed a urine leak extending from the lower aspect of the transplant kidney to the floor of the pelvic cavity, presacral region and the scrotum via right inguinal canal as well as to the right abdominal wall. Conclusions Renal scintigraphy is very useful to detect a urine leak after renal transplantation. However, planar imaging is sometimes limited in evaluating the anatomical location and extent of a urine leak accurately. In that case accompanying SPECT/CT images are very helpful and valuable to evaluate the anatomical relationships exactly.

  6. Resilience to leaking--dynamic systems modeling of information security.

    Science.gov (United States)

    Hamacher, Kay

    2012-01-01

    Leaking of confidential material is a major threat to information security within organizations and to society as a whole. This insight has gained traction in the political realm since the activities of Wikileaks, which hopes to attack 'unjust' systems or 'conspiracies'. Eventually, such threats to information security rely on a biologistic argument on the benefits and drawbacks that uncontrolled leaking might pose for 'just' and 'unjust' entities. Such biological metaphors are almost exclusively based on the economic advantage of participants. Here, I introduce a mathematical model of the complex dynamics implied by leaking. The complex interactions of adversaries are modeled by coupled logistic equations including network effects of econo-communication networks. The modeling shows, that there might arise situations where the leaking envisioned and encouraged by Wikileaks and the like can strengthen the defending entity (the 'conspiracy'). In particular, the only severe impact leaking can have on an organization seems to originate in the exploitation of leaks by another entity the organization competes with. Therefore, the model suggests that leaks can be used as a `tactical mean' in direct adversary relations, but do not necessarily increase public benefit and societal immunization to 'conspiracies'. Furthermore, within the model the exploitation of the (open) competition between entities seems to be a more promising approach to control malicious organizations : divide-et-impera policies triumph here.

  7. Resilience to leaking--dynamic systems modeling of information security.

    Directory of Open Access Journals (Sweden)

    Kay Hamacher

    Full Text Available Leaking of confidential material is a major threat to information security within organizations and to society as a whole. This insight has gained traction in the political realm since the activities of Wikileaks, which hopes to attack 'unjust' systems or 'conspiracies'. Eventually, such threats to information security rely on a biologistic argument on the benefits and drawbacks that uncontrolled leaking might pose for 'just' and 'unjust' entities. Such biological metaphors are almost exclusively based on the economic advantage of participants. Here, I introduce a mathematical model of the complex dynamics implied by leaking. The complex interactions of adversaries are modeled by coupled logistic equations including network effects of econo-communication networks. The modeling shows, that there might arise situations where the leaking envisioned and encouraged by Wikileaks and the like can strengthen the defending entity (the 'conspiracy'. In particular, the only severe impact leaking can have on an organization seems to originate in the exploitation of leaks by another entity the organization competes with. Therefore, the model suggests that leaks can be used as a `tactical mean' in direct adversary relations, but do not necessarily increase public benefit and societal immunization to 'conspiracies'. Furthermore, within the model the exploitation of the (open competition between entities seems to be a more promising approach to control malicious organizations : divide-et-impera policies triumph here.

  8. Resilience to Leaking — Dynamic Systems Modeling of Information Security

    Science.gov (United States)

    Hamacher, Kay

    2012-01-01

    Leaking of confidential material is a major threat to information security within organizations and to society as a whole. This insight has gained traction in the political realm since the activities of Wikileaks, which hopes to attack ‘unjust’ systems or ‘conspiracies’. Eventually, such threats to information security rely on a biologistic argument on the benefits and drawbacks that uncontrolled leaking might pose for ‘just’ and ‘unjust’ entities. Such biological metaphors are almost exclusively based on the economic advantage of participants. Here, I introduce a mathematical model of the complex dynamics implied by leaking. The complex interactions of adversaries are modeled by coupled logistic equations including network effects of econo-communication networks. The modeling shows, that there might arise situations where the leaking envisioned and encouraged by Wikileaks and the like can strengthen the defending entity (the ‘conspiracy’). In particular, the only severe impact leaking can have on an organization seems to originate in the exploitation of leaks by another entity the organization competes with. Therefore, the model suggests that leaks can be used as a `tactical mean’ in direct adversary relations, but do not necessarily increase public benefit and societal immunization to ‘conspiracies’. Furthermore, within the model the exploitation of the (open) competition between entities seems to be a more promising approach to control malicious organizations : divide-et-impera policies triumph here. PMID:23227151

  9. Leak Path Development in CO2 Wells

    Science.gov (United States)

    Torsater, M.; Todorovic, J.; Opedal, N.; Lavrov, A.

    2014-12-01

    Wells have in numerous scientific works been denoted the "weak link" of safe and cost-efficient CO2 Capture and Storage (CCS). Whether they are active or abandoned, all wells are man-made intrusions into the storage reservoir with sealing abilities depending on degradable materials like steel and cement. If dense CO2 is allowed to expand (e.g. due to leakage) it will cool down its surroundings and cause strong thermal and mechanical loading on the wellbore. In addition, CO2 reacts chemically with rock, cement and steel. To ensure long-term underground containment, it is therefore necessary to study how, why, where and when leakage occurs along CO2wells. If cement bonding to rock or casing is poor, leak paths can form already during drilling and completion of the well. In the present work, we have mapped the bonding quality of cement-rock and cement-steel interfaces - and measured their resistance towards CO2 flow. This involved a large experimental matrix including different rocks, steels, cement types and well fluids. The bonding qualities were measured on composite cores using micro computed tomography (µ-CT), and CO2 was flooded through the samples to determine leakage rates. These were further compared to numerical simulations of leakage through the digitalized µ-CT core data, and CO2chemical interactions with the materials were mapped using electron microscopy. We also present a new laboratory set-up for measuring how well integrity is affected by downhole temperature variations - and we showcase some initial results. Our work concludes that leak path development in CO2 wells depends critically on the drilling fluids and presflushes/spacers chosen already during drilling and completion of a well. Fluid films residing on rock and casing surfaces strongly degrade the quality of cement bonding. The operation of the well is also important, as even slight thermal cycling (between 10°C and 95°C on casing) leads to significant de-bonding of the annular cement.

  10. Toward a better guard of coastal water safety-Microbial distribution in coastal water and their facile detection.

    Science.gov (United States)

    Xie, Yunxuan; Qiu, Ning; Wang, Guangyi

    2017-05-15

    Prosperous development in marine-based tourism has raised increasing concerns over the sanitary quality of coastal waters with potential microbial contamination. The World Health Organization has set stringent standards over a list of pathogenic microorganisms posing potential threats to people with frequent coastal water exposure and has asked for efficient detection procedures for pathogen facile identification. Inspection of survey events regarding the occurrence of marine pathogens in recreational beaches in recent years has reinforced the need for the development of a rapid identification procedure. In this review, we examine the possibility of recruiting uniform molecular assays to identify different marine pathogens and the feasibility of appropriate biomarkers, including enterochelin biosynthetic genes, for general toxicity assays. The focus is not only on bacterial pathogens but also on other groups of infectious pathogens. The ultimate goal is the development of a handy method to more efficiently and rapidly detect marine pathogens. Copyright © 2017 Elsevier Ltd. All rights reserved.

  11. A pre-enrichment step is essential for detection of Campylobacter sp. in turbid pond water.

    Science.gov (United States)

    Abulreesh, H H; Paget, T A; Goulder, R

    2014-06-01

    This work aimed to detect Campylobacter species from naturally contaminated turbid pond water by PCR. A total of 16 water samples were collected from a turbid village pond. Four methods of DNA extraction were applied to centrifuge pellets from eight 100 ml pond water samples prior to attempted detection of Campylobacter by PCR without an enrichment step. These methods were (1) Tris-HCl and sodium dodecyl sulfate followed by phenol:chloroform:isoamylalcohol extraction followed by treatment with DNA clean up kit, (2) proteinase K, (3) Chelex® 100, and (4) boiling. The other eight pond water samples (10 ml and 100 ml) were filtered and filters were incubated overnight in Preston enrichment broth. The centrifuge pellets obtained from enrichment cultures were treated by proteinase K for DNA extraction. Primers CF03 and CF04 for the flagellin genes (flaA and flaB) of Campylobacter jejuni and Campylobacter coli were used for amplifying the extracted DNA. The DNA extracted from eight-100 ml pond water samples that were not subject to selective enrichment was never amplified with primers CF03 and CF04, hence Campylobacter was not detected. In contrast, the DNA that was from samples that were subjected to a selective enrichment step in Preston broth prior to PCR assay always gave amplified bands of 340-380 bp, therefore the presence of Campylobacter was confirmed. Detection of campylobacters from naturally contaminated, turbid, environmental water may not be feasible by direct PCR assay because of low numbers and the presence of high concentration of humic matter and other PCR inhibitors. The enrichment of water samples in selective broth, however, facilitated PCR detection of Campylobacter probably by increasing cell number and by diluting PCR inhibitors.

  12. Detection of pathogenic Batrachochytrium dendrobatidis using water filtration, animal and bait testing.

    Science.gov (United States)

    Wimsatt, Jeffrey; Feldman, Sanford H; Heffron, Meghan; Hammond, Meagan; Ruehling, Margaret P Roth; Grayson, Kristine L; Mitchell, Joseph C

    2014-01-01

    The pathogen Batrachochytrium dendrobatidis (Bd) can be challenging to detect at endangered amphibian reintroduction sites. Pre-release Bd detection can be confounded by imperfect animal sampling and the absence of animals. In Study 1, we used historical Bd-positive sites, to concurrently evaluate water filtrates and mouth bar (tadpoles) or skin swab (caudates) samples for Bd using molecular beacon realtime PCR. In Study 2, during a natural outbreak, we used PCR to detect Bd from zoospore-attracting keratin baits (three avian, three snake species). In Study 1, no captured animals (n=116) exhibited clinical signs, although 10.6% were positive, representing three of seven species sampled. In contrast, 5.4% of water filters (n=56) were Bd-positive. In Study 2, after short incubation times, a single duck down feather tested Bd-positive. In conclusion, Bd was detected in asymptomatic amphibians and water filtrate at two sites, and from water only, at two other sites. With continued refinement, semi-quantitative Bd water filtrate screening could better define zoospore-specific disease risk, allowing better characterization of the free-living phase of the organism's life cycle. Finally, these results suggest wild aquatic birds (e.g., waterfowl) should be systematically explored as a means of Bd spread. Since large numbers of aquatic birds migrate, even low Bd transfer rates could be a significant means for disease dissemination. © 2014 Wiley Periodicals, Inc.

  13. Effective detection of human adenovirus in hawaiian waters using enhanced pcr methods

    Directory of Open Access Journals (Sweden)

    Lu Yuanan

    2011-02-01

    Full Text Available Abstract Background The current criteria for recreational water quality evaluation are primarily based on measurements of fecal indicator bacteria growth. However, these criteria often fail to predict the presence of waterborne human pathogenic viruses. To explore the possibility of direct use of human enteric viruses as improved human fecal contamination indicators, human adenovirus (HAdV was tested as a model in this study. Findings In order to establish a highly sensitive protocol for effective detection of HAdV in aquatic environments, sixteen published PCR primer sets were re-optimized and comparatively evaluated. Primer sets nehex3deg/nehex4deg, ADV-F/ADV-R, and nested PCR primer sets hex1deg/hex2deg and nehex3deg/nehex4deg were identified to be the most sensitive ones, with up to 1,000 fold higher detection sensitivity compared to other published assays. These three PCR protocols were successfully employed to detect HAdV in both treated and untreated urban wastewaters, and also in 6 of 16 recreational water samples collected around the island of Oahu, Hawaii. Conclusions Findings from this study support the possible use of enteric viruses for aquatic environmental monitoring, specifically for the essential routine monitoring of Hawaiian beach waters using the optimized PCR protocol to detect HAdV at certain water sites to ensure a safe use of recreational waters.

  14. Microfluidic chip with optical sensor for rapid detection of nerve agent Sarin in water samples

    Science.gov (United States)

    Tan, Hsih Yin; Nguyen, Nam-Trung; Loke, Weng Keong; Tan, Yong Teng

    2007-12-01

    The chemical warfare agent Sarin is an organophosphate that is highly toxic to humans as they can act as cholinesterase inhibitors, that disrupts neuromuscular transmission. As these nerve agents are colorless, odorless and highly toxic, they can be introduced into drinking water as a means of terrorist sabotage. Hence, numerous innovative devices and methods have been developed for rapid detection of these organophosphates. Microfluidic technology allows the implementation of fast and sensitive detection of Sarin. In this paper, a micro-total analysis systems (TAS), also known as Lab-on-a-chip, fitted with an optical detection system has been developed to analyze the presence of the nerve agent sarin in water samples. In the present set-up, inhibition of co-introduced cholinesterase and water samples containing trace amounts of nerve agent sarin into the microfluidic device was used as the basis for selective detection of sarin. The device was fabricated using polymeric micromachining with PMMA (poly (methymethacrylate)) as the substrate material. A chromophore was utilized to measure the activity of remnant cholinesterase activity, which is inversely related to the amount of sarin present in the water samples. Comparisons were made between two different optical detection techniques and the findings will be presented in this paper. The presented measurement method is simple, fast and as sensitive as Gas Chromatography.

  15. Detection and spatial mapping of mercury contamination in water samples using a smart-phone.

    Science.gov (United States)

    Wei, Qingshan; Nagi, Richie; Sadeghi, Kayvon; Feng, Steve; Yan, Eddie; Ki, So Jung; Caire, Romain; Tseng, Derek; Ozcan, Aydogan

    2014-02-25

    Detection of environmental contamination such as trace-level toxic heavy metal ions mostly relies on bulky and costly analytical instruments. However, a considerable global need exists for portable, rapid, specific, sensitive, and cost-effective detection techniques that can be used in resource-limited and field settings. Here we introduce a smart-phone-based hand-held platform that allows the quantification of mercury(II) ions in water samples with parts per billion (ppb) level of sensitivity. For this task, we created an integrated opto-mechanical attachment to the built-in camera module of a smart-phone to digitally quantify mercury concentration using a plasmonic gold nanoparticle (Au NP) and aptamer based colorimetric transmission assay that is implemented in disposable test tubes. With this smart-phone attachment that weighs smart application was utilized to process each acquired transmission image on the same phone to achieve a limit of detection of ∼ 3.5 ppb. Using this smart-phone-based detection platform, we generated a mercury contamination map by measuring water samples at over 50 locations in California (USA), taken from city tap water sources, rivers, lakes, and beaches. With its cost-effective design, field-portability, and wireless data connectivity, this sensitive and specific heavy metal detection platform running on cellphones could be rather useful for distributed sensing, tracking, and sharing of water contamination information as a function of both space and time.

  16. Molecular detection and characterization of Aichi viruses in sewage-polluted waters of Venezuela.

    Science.gov (United States)

    Alcalá, Ana; Vizzi, Esmeralda; Rodríguez-Díaz, Jesús; Zambrano, José L; Betancourt, Walter; Liprandi, Ferdinando

    2010-06-01

    The circulation of Aichi virus in a major urban area was demonstrated using molecular detection with samples recovered from a major river polluted with sewage discharges in Caracas, Venezuela. Five out of 11 water samples studied were positive, being classified by phylogenetic analysis as genotype B. Analysis of sewage waters appears to be a useful methodology to uncover the presence of a hitherto undetected fecal pathogen in a given geographical area.

  17. Evaluation of LLTR Series II test A-2 results. [Large Leak Test Rig

    Energy Technology Data Exchange (ETDEWEB)

    Whipple, J C; Shoopak, B F; Chen, K; Fan, C K; Odegaard, T K

    1980-07-01

    Series II Test A-2 employed a double-ended (DEG) tube rupture 122'' above the lower end of the LLTI shroud under typical evaporator startup conditions. The leak site was located 2'' below Spacer No. 4 at the same location as Test A-lb which employed nitrogen as the inert non-reactive injection fluid. The test yielded peak pressures of 375 psig in the leak site region and 485 psig at the upper tubesheet approximately 10 ms and 12 ms, respectively, after tube rupture. Higher peak temperatures (approx. 2200/sup 0/F) were measured in this test than during Series I sodium-water reaction testing (peak temperatures measured during Series were about 1900/sup 0/F maximum). These high peak temperatures occurred in Test A-2 long after the tube rupture (approx. 8 seconds) and did not contribute to the acoustic peak pressures produced in the first few milliseconds.

  18. Cloud-enabled microscopy and droplet microfluidic platform for specific detection of Escherichia coli in water.

    Directory of Open Access Journals (Sweden)

    Alexander Golberg

    Full Text Available We report an all-in-one platform - ScanDrop - for the rapid and specific capture, detection, and identification of bacteria in drinking water. The ScanDrop platform integrates droplet microfluidics, a portable imaging system, and cloud-based control software and data storage. The cloud-based control software and data storage enables robotic image acquisition, remote image processing, and rapid data sharing. These features form a "cloud" network for water quality monitoring. We have demonstrated the capability of ScanDrop to perform water quality monitoring via the detection of an indicator coliform bacterium, Escherichia coli, in drinking water contaminated with feces. Magnetic beads conjugated with antibodies to E. coli antigen were used to selectively capture and isolate specific bacteria from water samples. The bead-captured bacteria were co-encapsulated in pico-liter droplets with fluorescently-labeled anti-E. coli antibodies, and imaged with an automated custom designed fluorescence microscope. The entire water quality diagnostic process required 8 hours from sample collection to online-accessible results compared with 2-4 days for other currently available standard detection methods.

  19. [Detecting Thallium in Water Samples using Dispersive Liquid Phase Microextraction-Graphite Furnace Atomic Absorption Spectroscopy].

    Science.gov (United States)

    Zhu, Jing; Li, Yan; Zheng, Bo; Tang, Wei; Chen, Xiao; Zou, Xiao-li

    2015-11-01

    To develope a method of solvent demulsification dispersive liquid phase microextraction (SD-DLPME) based on ion association reaction coupled with graphite furnace atomic absorption spectroscopy (GFAAS) for detecting thallium in water samples. Methods Thallium ion in water samples was oxidized to Tl(III) with bromine water, which reacted with Cl- to form TlCl4-. The ionic associated compound with trioctylamine was obtained and extracted. DLPME was completed with ethanol as dispersive solvent. The separation of aqueous and organic phase was achieved by injecting into demulsification solvent without centrifugation. The extractant was collected and injected into GFAAS for analysis. With palladium colloid as matrix modifier, a two step drying and ashing temperature programming process was applied for high precision and sensitivity. The linear range was 0.05-2.0 microg/L, with a detection limit of 0.011 microg/L. The relative standard derivation (RSD) for detecting Tl in spiked water sample was 9.9%. The spiked recoveries of water samples ranged from 94.0% to 103.0%. The method is simple, sensitive and suitable for batch analysis of Tl in water samples.

  20. Early warning system for detection of microbial contamination of source waters

    DEFF Research Database (Denmark)

    Mogensen, Claus Tilsted; Bentien, Anders; Lau, Mogens

    2011-01-01

    Ensuring chemical and microbial water quality is an ever increasing important issue world-wide. Currently, determination of microbial water quality is a time (and money) consuming manual laboratory process. We have developed and field-tested an online and real-time sensor for measuring the microb....../or variation. This includes: water plants/water distribution networks, filtration systems (water purification), commercial buildings, swimming pools, waste water effluent, and industry in general.......Ensuring chemical and microbial water quality is an ever increasing important issue world-wide. Currently, determination of microbial water quality is a time (and money) consuming manual laboratory process. We have developed and field-tested an online and real-time sensor for measuring...... the microbial water quality of a wide range of source waters. The novel optical technique, in combination with advanced data analysis, yields a measure for the microbial content present in the sample. This gives a fast and reliable detection capability of microbial contamination of the source. Sample...

  1. Testing the applicability of rapid on-site enzymatic activity detection for surface water monitoring

    Science.gov (United States)

    Stadler, Philipp; Vogl, Wolfgang; Juri, Koschelnik; Markus, Epp; Maximilian, Lackner; Markus, Oismüller; Monika, Kumpan; Peter, Strauss; Regina, Sommer; Gabriela, Ryzinska-Paier; Farnleitner Andreas, H.; Matthias, Zessner

    2015-04-01

    On-site detection of enzymatic activities has been suggested as a rapid surrogate for microbiological pollution monitoring of water resources (e.g. using glucuronidases, galactosidases, esterases). Due to the possible short measuring intervals enzymatic methods have high potential as near-real time water quality monitoring tools. This presentation describes results from a long termed field test. For twelve months, two ColiMinder devices (Vienna Water Monitoring, Austria) for on-site determination of enzymatic activity were tested for stream water monitoring at the experimental catchment HOAL (Hydrological Open Air Laboratory, Center for Water Resource Systems, Vienna University of Technology). The devices were overall able to follow and reflect the diverse hydrological and microbiological conditions of the monitored stream during the test period. Continuous data in high temporal resolution captured the course of enzymatic activity in stream water during diverse rainfall events. The method also proofed sensitive enough to determine diurnal fluctuations of enzymatic activity in stream water during dry periods. The method was able to capture a seasonal trend of enzymatic activity in stream water that matches the results gained from Colilert18 analysis for E. coli and coliform bacteria of monthly grab samples. Furthermore the comparison of ColiMinder data with measurements gained at the same test site with devices using the same method but having different construction design (BACTcontrol, microLAN) showed consistent measuring results. Comparative analysis showed significant differences between measured enzymatic activity (modified fishman units and pmol/min/100ml) and cultivation based analyses (most probable number, colony forming unit). Methods of enzymatic activity measures are capable to detect ideally the enzymatic activity caused by all active target bacteria members, including VBNC (viable but nonculturable) while cultivation based methods cannot detect VBNC

  2. Evaluation of Drought Management Measures for Municipal and Industrial Water Supply.

    Science.gov (United States)

    1983-12-01

    American Society of Civil Engineers 100:621-630. : 130. Moran, E. 1978. Waterless Toilets--Modern Home Systems Turn Waste into Compost. Popular Science 212...to flat rates. There was strong objection (92% of the respondents) to dyeing or giving the water an unpleasant taste as a warning to consumers to...Each kit contained a toilet water dam, a plastic shower-head restrictor, and a packet of vegetable dye tablets to detect leaks from toilet storage tanks

  3. Molecular Detection of Leptospiral DNA in Environmental Water on St. Kitts

    Directory of Open Access Journals (Sweden)

    Julienne Rawlins

    2014-08-01

    Full Text Available Leptospirosis is an important waterborne zoonotic disease caused by pathogenic Leptospira. The pathogen is maintained in a population due to chronic colonization and shedding from renal tubules of domestic and wild animals. Humans and other animals become infected when they come in contact with urine from infected animals, either directly or through urine-contaminated surface water. In this study, we screened environmental water on the island of St. Kitts by using a TaqMan based real time quantitative polymerase chain reaction (qPCR targeting a pathogen specific leptospiral gene, lipl32. Our results indicate that around one-fifth of tested water sources have detectable leptospiral DNA.

  4. Structure detection in a libration vibration spectrum of water molecules by methods of nonlinear optics

    Energy Technology Data Exchange (ETDEWEB)

    Babenko, V A; Sychev, Andrei A [P N Lebedev Physical Institute, Russian Academy of Sciences, Moscow (Russian Federation)

    2012-09-30

    In exciting water possessing an enhanced optical strength by the radiation of a YAG : Nd{sup 3+} laser with 20-ps pulses, nonlinear scattering of light was detected in the frequency range of the optical second harmonic. A relationship was established of the signal of the nonlinear scattering with a stimulated Raman scattering (SRS) of the laser radiation in water. Near the SRS threshold, the structure was observed in the spectrum of nonlinear scattering, which is related to intermolecular libration vibrations of water molecules. (laser applications and other topics in quantum electronics)

  5. JAWS: Just Add Water System - A device for detection of nucleic acids in Martian ice caps

    DEFF Research Database (Denmark)

    Hansen, Anders J.; Willerslev, Eske; Mørk, Søren

    2002-01-01

    The design of a device for nucleic acid detection in the Martian ice caps is presented; the Just Add Water System (JAWS). It is based on fiber-optic PNA (peptide nucleic acid) light up probe random microsphere universal array technology. JAWS is designed to be part of a larger system...... with a regulation of pH and salt concentrations e.g. the MOD systems and could be installed on a planetary probe melting its way down the Martian ice caps e.g. the NASA Cryobot. JAWS can be used for detection of remains of ancient life preserved in the Martian ice as well as for detection of contamination brought...

  6. Geochemical detection of carbon dioxide in dilute aquifers

    Directory of Open Access Journals (Sweden)

    Aines Roger

    2009-03-01

    Full Text Available Abstract Background Carbon storage in deep saline reservoirs has the potential to lower the amount of CO2 emitted to the atmosphere and to mitigate global warming. Leakage back to the atmosphere through abandoned wells and along faults would reduce the efficiency of carbon storage, possibly leading to health and ecological hazards at the ground surface, and possibly impacting water quality of near-surface dilute aquifers. We use static equilibrium and reactive transport simulations to test the hypothesis that perturbations in water chemistry associated with a CO2 gas leak into dilute groundwater are important measures for the potential release of CO2 to the atmosphere. Simulation parameters are constrained by groundwater chemistry, flow, and lithology from the High Plains aquifer. The High Plains aquifer is used to represent a typical sedimentary aquifer overlying a deep CO2 storage reservoir. Specifically, we address the relationships between CO2 flux, groundwater flow, detection time and distance. The CO2 flux ranges from 103 to 2 × 106 t/yr (0.63 to 1250 t/m2/yr to assess chemical perturbations resulting from relatively small leaks that may compromise long-term storage, water quality, and surface ecology, and larger leaks characteristic of short-term well failure. Results For the scenarios we studied, our simulations show pH and carbonate chemistry are good indicators for leakage of stored CO2 into an overlying aquifer because elevated CO2 yields a more acid pH than the ambient groundwater. CO2 leakage into a dilute groundwater creates a slightly acid plume that can be detected at some distance from the leak source due to groundwater flow and CO2 buoyancy. pH breakthrough curves demonstrate that CO2 leaks can be easily detected for CO2 flux ≥ 104 t/yr within a 15-month time period at a monitoring well screened within a permeable layer 500 m downstream from the vertical gas trace. At lower flux rates, the CO2 dissolves in the aqueous phase

  7. Detection and enumeration of coliforms in drinking water: current methods and emerging approaches.

    Science.gov (United States)

    Rompré, Annie; Servais, Pierre; Baudart, Julia; de-Roubin, Marie Renée; Laurent, Patrick

    2002-03-01

    The coliform group has been used extensively as an indicator of water quality and has historically led to the public health protection concept. The aim of this review is to examine methods currently in use or which can be proposed for the monitoring of coliforms in drinking water. Actually, the need for more rapid, sensitive and specific tests is essential in the water industry. Routine and widely accepted techniques are discussed, as are methods which have emerged from recent research developments.Approved traditional methods for coliform detection include the multiple-tube fermentation (MTF) technique and the membrane filter (MF) technique using different specific media and incubation conditions. These methods have limitations, however, such as duration of incubation, antagonistic organism interference, lack of specificity and poor detection of slow-growing or viable but non-culturable (VBNC) microorganisms. Nowadays, the simple and inexpensive membrane filter technique is the most widely used method for routine enumeration of coliforms in drinking water.The detection of coliforms based on specific enzymatic activity has improved the sensitivity of these methods. The enzymes beta-D galactosidase and beta-D glucuronidase are widely used for the detection and enumeration of total coliforms and Escherichia coli, respectively. Many chromogenic and fluorogenic substrates exist for the specific detection of these enzymatic activities, and various commercial tests based on these substrates are available. Numerous comparisons have shown these tests may be a suitable alternative to the classical techniques. They are, however, more expensive, and the incubation time, even though reduced, remains too long for same-day results. More sophisticated analytical tools such as solid phase cytometry can be employed to decrease the time needed for the detection of bacterial enzymatic activities, with a low detection threshold. Detection of coliforms by molecular methods is also

  8. Environmental occurrence and shallow ground water detection of the antibiotic monensin from dairy farms

    Science.gov (United States)

    Watanabe, N.; Harter, T.H.; Bergamaschi, B.A.

    2008-01-01

    Pharmaceuticals used in animal feeding operations have been detected in various environmental settings. There is a growing concern about the impact on terrestrial and aquatic organisms and the development of antibiotic-resistant strains of microorganisms. Pharmaceutical use in milking cows is relatively limited compared with other livestock operations, except for the ionophore monensin, which is given to lactating cows as a feed. By weight, monensin can be the most significant antibiotic used in a dairy farm. This study investigates the potential of monensin to move from dairy operations into the surrounding ground water. Using two dairy farms in California as study sites, we twice collected samples along the environmental pathway-from flush lanes, lagoon waters, and shallow ground water beneath the dairies and beneath its associated manured fields. Monensin concentrations were determined using solid-phase extraction and liquid chromatography-tandem mass spectrometry with positive electrospray ionization. Monensin was detected in all of the flush lane and lagoon water samples. Theoretical maximum concentration estimated from the actual dosing rate and the theoretical excretion rate assuming no attenuation was one order of magnitude greater than observed concentrations, suggesting significant attenuation in the manure collection and storage system. Monensin was also detected, at levels ranging from 0.04 to 0.39 microg L(-1), in some of the ground water samples underneath the production area of the dairy but not from the adjacent manured fields. Concentrations in ground water immediately downgradient of the lagoons were one to two orders of magnitude lower than the concentrations detected in lagoons, suggesting attenuation in the subsurface. The data suggest the possibility of monensin transport into shallow (2-5 m) alluvial ground water from dairy management units, including manure storage lagoons and freestalls occupied by heifers, lactating cows, and dry cows.

  9. Application of principal component regression and partial least squares regression in ultraviolet spectrum water quality detection

    Science.gov (United States)

    Li, Jiangtong; Luo, Yongdao; Dai, Honglin

    2018-01-01

    Water is the source of life and the essential foundation of all life. With the development of industrialization, the phenomenon of water pollution is becoming more and more frequent, which directly affects the survival and development of human. Water quality detection is one of the necessary measures to protect water resources. Ultraviolet (UV) spectral analysis is an important research method in the field of water quality detection, which partial least squares regression (PLSR) analysis method is becoming predominant technology, however, in some special cases, PLSR's analysis produce considerable errors. In order to solve this problem, the traditional principal component regression (PCR) analysis method was improved by using the principle of PLSR in this paper. The experimental results show that for some special experimental data set, improved PCR analysis method performance is better than PLSR. The PCR and PLSR is the focus of this paper. Firstly, the principal component analysis (PCA) is performed by MATLAB to reduce the dimensionality of the spectral data; on the basis of a large number of experiments, the optimized principal component is extracted by using the principle of PLSR, which carries most of the original data information. Secondly, the linear regression analysis of the principal component is carried out with statistic package for social science (SPSS), which the coefficients and relations of principal components can be obtained. Finally, calculating a same water spectral data set by PLSR and improved PCR, analyzing and comparing two results, improved PCR and PLSR is similar for most data, but improved PCR is better than PLSR for data near the detection limit. Both PLSR and improved PCR can be used in Ultraviolet spectral analysis of water, but for data near the detection limit, improved PCR's result better than PLSR.

  10. Low Cost Lab on Chip for the Colorimetric Detection of Nitrate in Mineral Water Products

    Directory of Open Access Journals (Sweden)

    Mohammad F. Khanfar

    2017-10-01

    Full Text Available The diagnostics of health status and the quality of drinking water are among the most important United Nations sustainable development goals. However, in certain areas, wars and instability have left millions of people setting in refugee camps and dangerous regions where infrastructures are lacking and rapid diagnostics of water quality and medical status are critical. In this work, microfluidic testing chips and photometric setups are developed in cheap and portable way to detect nitrate concentrations in water. The performed test is designed to work according to the Griess procedure. Moreover, to make it simple and usable in areas of low resource settings, commercially available Arduino mega and liquid crystal display (LCD shield are utilized to process and display results, respectively. For evaluation purposes, different local products of tap water, bottled drinking water, and home-filter treated water samples were tested using the developed setup. A calibration curve with coefficient of determination (R2 of 0.98 was obtained when absorbance of the prepared standard solutions was measured as a function of the concentrations. In conclusion, this is the first step towards a compact, portable, and reliable system for nitrate detection in water for point-of-care applications.

  11. Low Cost Lab on Chip for the Colorimetric Detection of Nitrate in Mineral Water Products.

    Science.gov (United States)

    Khanfar, Mohammad F; Al-Faqheri, Wisam; Al-Halhouli, Ala'aldeen

    2017-10-14

    The diagnostics of health status and the quality of drinking water are among the most important United Nations sustainable development goals. However, in certain areas, wars and instability have left millions of people setting in refugee camps and dangerous regions where infrastructures are lacking and rapid diagnostics of water quality and medical status are critical. In this work, microfluidic testing chips and photometric setups are developed in cheap and portable way to detect nitrate concentrations in water. The performed test is designed to work according to the Griess procedure. Moreover, to make it simple and usable in areas of low resource settings, commercially available Arduino mega and liquid crystal display (LCD) shield are utilized to process and display results, respectively. For evaluation purposes, different local products of tap water, bottled drinking water, and home-filter treated water samples were tested using the developed setup. A calibration curve with coefficient of determination (R²) of 0.98 was obtained when absorbance of the prepared standard solutions was measured as a function of the concentrations. In conclusion, this is the first step towards a compact, portable, and reliable system for nitrate detection in water for point-of-care applications.

  12. Detection of Hg2+ in water environment by fluorescence spectroscopic methods

    Science.gov (United States)

    Li, Zhen; Zhang, Jinsong; Hu, Hong; Wan, Ruyi; Yao, Youwei

    2015-08-01

    Inorganic mercury (Hg2+) produces toxic effects even at very low concentration. High sensitive fluorescent probes for Hg2+ detection has been researched and synthesized. A fluorescence detection system is built for Hg2+ detection in water environment with fluorescent probes as the detection reagent. Fiber coupled LED with high brightness is developed and used as excitation light source. And the optimized excitation wavelength is about 520 nm. The measurements of fluorescence spectra is obtained by means of optical fiber spectroscopic techniques. Fluorescence detection experiments are carried out for a range of different concentrations of Hg2+ in aqueous solutions. The center wavelength of the fluorescence spectra is about 580 nm which is unchanged in the experiments. Relationship between Hg2+ concentrations and the fluorescence intensity is studied. A positive correlation exists between the intensity of fluorescence spectrum and the concentrations of Hg2+. The fluorescence intensity grows with increasing the concentration of Hg2+ for the same excitation light. When the concentration of Hg2+ is high enough, the fluorescence intensity increases slowly. And a numerical model is built for the concentration calculating. The detection limit is 0.005 μmol/L in the experiments. The Hg2+ detection system reported has many advantages such as small size, rapid response, high-sensitivity, and can be used for on-site testing of the water quality.

  13. Comprehensive Detection of Gas Plumes from Multibeam Water Column Images with Minimisation of Noise Interferences

    Directory of Open Access Journals (Sweden)

    Jianhu Zhao

    2017-11-01

    Full Text Available Multibeam echosounder systems (MBES can record backscatter strengths of gas plumes in the water column (WC images that may be an indicator of possible occurrence of gas at certain depths. Manual or automatic detection is generally adopted in finding gas plumes, but frequently results in low efficiency and high false detection rates because of WC images that are polluted by noise. To improve the efficiency and reliability of the detection, a comprehensive detection method is proposed in this paper. In the proposed method, the characteristics of WC background noise are first analyzed and given. Then, the mean standard deviation threshold segmentations are respectively used for the denoising of time-angle and depth-angle images, an intersection operation is performed for the two segmented images to further weaken noise in the WC data, and the gas plumes in the WC data are detected from the intersection image by the morphological constraint. The proposed method was tested by conducting shallow-water and deepwater experiments. In these experiments, the detections were conducted automatically and higher correct detection rates than the traditional methods were achieved. The performance of the proposed method is analyzed and discussed.

  14. Immunoassays and Biosensors for the Detection of Cyanobacterial Toxins in Water

    Directory of Open Access Journals (Sweden)

    Michael G. Weller

    2013-11-01

    Full Text Available Algal blooms are a frequent phenomenon in nearly all kinds of fresh water. Global warming and eutrophication by waste water, air pollution and fertilizers seem to lead to an increased frequency of occurrence. Many cyanobacteria produce hazardous and quite persistent toxins, which can contaminate the respective water bodies. This may limit the use of the raw water for many purposes. The purification of the contaminated water might be quite costly, which makes a continuous and large scale treatment economically unfeasible in many cases. Due to the obvious risks of algal toxins, an online or mobile detection method would be highly desirable. Several biosensor systems have been presented in the literature for this purpose. In this review, their mode of operation, performance and general suitability for the intended purpose will be described and critically discussed. Finally, an outlook on current developments and future prospects will be given.

  15. Multiple-Feature Extracting Modules Based Leak Mining System Design

    Science.gov (United States)

    Cho, Ying-Chiang; Pan, Jen-Yi

    2013-01-01

    Over the years, human dependence on the Internet has increased dramatically. A large amount of information is placed on the Internet and retrieved from it daily, which makes web security in terms of online information a major concern. In recent years, the most problematic issues in web security have been e-mail address leakage and SQL injection attacks. There are many possible causes of information leakage, such as inadequate precautions during the programming process, which lead to the leakage of e-mail addresses entered online or insufficient protection of database information, a loophole that enables malicious users to steal online content. In this paper, we implement a crawler mining system that is equipped with SQL injection vulnerability detection, by means of an algorithm developed for the web crawler. In addition, we analyze portal sites of the governments of various countries or regions in order to investigate the information leaking status of each site. Subsequently, we analyze the database structure and content of each site, using the data collected. Thus, we make use of practical verification in order to focus on information security and privacy through black-box testing. PMID:24453892

  16. Multiple-feature extracting modules based leak mining system design.

    Science.gov (United States)

    Cho, Ying-Chiang; Pan, Jen-Yi

    2013-01-01

    Over the years, human dependence on the Internet has increased dramatically. A large amount of information is placed on the Internet and retrieved from it daily, which makes web security in terms of online information a major concern. In recent years, the most problematic issues in web security have been e-mail address leakage and SQL injection attacks. There are many possible causes of information leakage, such as inadequate precautions during the programming process, which lead to the leakage of e-mail addresses entered online or insufficient protection of database information, a loophole that enables malicious users to steal online content. In this paper, we implement a crawler mining system that is equipped with SQL injection vulnerability detection, by means of an algorithm developed for the web crawler. In addition, we analyze portal sites of the governments of various countries or regions in order to investigate the information leaking status of each site. Subsequently, we analyze the database structure and content of each site, using the data collected. Thus, we make use of practical verification in order to focus on information security and privacy through black-box testing.

  17. RCS Leak rate Calculation Using Bilateral Kernel Filters

    Energy Technology Data Exchange (ETDEWEB)

    Heo, Gyun Young; Jang, Seok Bo; Kim, So Young [Kyung Hee University, Yongin (Korea, Republic of); Ahn, Sang Ha [Korea Advanced Institute of Science and Technology, Daejeon (Korea, Republic of)

    2009-05-15

    The leakage from a RCS (Reactor Coolant System) is classified into identified leakage which is defined as leakage into the closed system boundaries so that it can be captured and unidentified leakage which is all other leakages. The timely and accurate detection of the unidentified leakage has significant meaning from a viewpoint of nuclear safety. The unidentified leakage was typically determined by the RCS inventory balance method that NUREG-1107 recommended, which was the most preferable algorithm accepted in NPPs. However, it turned out that the accuracy of the conventional method was quite susceptible to measurement uncertainty. To enhance the robustness of the RCS inventory balance method, NUREG/CR-6582 indicated such a trouble can be eliminated by using filtering techniques, for example, such as a linear regression. On the basis of this recommendation, many of the NPPs including Korean NPPs have accepted the calculation algorithm which is based on the linear regression to eliminate noises or fluctuations. It should be noted that there are still technical issues, for example, how to deal with transient conditions. Since the accuracy of leak rate calculation is also strongly dependent on the step change in thermo-hydraulic conditions or inventories, any transient conditions such as injection or discharge modes should be avoided during a test period. Particularly, as transient conditions take place, the linear regression is of no use and what's worse is it may output junk results, which must be very confused to operators. In order to enhance the capability of the RCS inventory balance method in transient conditions as well as steady state operations, the study using Kalman filter and smoother techniques which have the system state modeling capability was proposed. After this study, we concluded that the study on the leak rate calculation would be worthwhile as not only a practical application to NPPs but also an academic concern. To extensively investigate

  18. Leaking Underground Tanks in Rhode Island; LUSTs12

    Data.gov (United States)

    University of Rhode Island Geospatial Extension Program — This dataset shows the location of storage tanks and associated piping used for petroleum and certain hazardous substances that have experienced leaks as determined...

  19. The world is polluted with leaked cyber data

    CSIR Research Space (South Africa)

    Burke, Ivan D

    2017-10-01

    Full Text Available Data breaches are becoming more common and numerous every day, where huge amount of data (corporate and personal) are leaked more frequently than ever. Corporate responses to data breaches are insufficient, when commonly remediation is minimal...

  20. Anastomotic leak after oesophagectomy and stent implantation: a systematic review

    Directory of Open Access Journals (Sweden)

    A.N. Kanatas

    2011-12-01

    Full Text Available Anastomotic leaks following oesophageal cancer resection have a high mortality. Stents have an established position in the palliation of dysphagia due to malignancy and in treating malignant perforation or fistula. They are increasingly used for benign conditions such as spontaneous oesophageal perforation with encouraging results. In this systematic review we examine the available evidence and attempt to define the role of stents in the management of oesophageal anastomotic leaks after resection for cancer. It is evident from the review that plastic- and metal-covered stents are an effective strategy for the treatment of anastomotic leaks. Vigilance is required as complications such as stent migration and incomplete sealing are not uncommon. Further clinical studies with greater methodological rigor in terms of sample size and study design may confirm that stents have an important contribution to make in the management of oesophageal anastomotic leak.

  1. Duodenal stump leak following a duodenal switch: A case report

    Directory of Open Access Journals (Sweden)

    Lars Nelson

    2015-01-01

    Conclusion: Duodenal stump leaks must be diagnosed as early as possible, and treated appropriately with operative intervention. Regardless of the operative technique the key to appropriate treatment is stabilize the patient, repair the duodenal stump, and adequate drainage.

  2. An ultrasonic array sensor for spacecraft leak direction finding.

    Science.gov (United States)

    Holland, Stephen D; Roberts, Ron; Chimenti, D E; Song, Jun Ho

    2006-12-01

    We have developed an ultrasonic array sensor useable for locating air leaks in manned spacecraft and have found that this sensor locates leaks in a 1-m(2) plate to within 2 cm. The sensor consists of a 63-element multiplexed array plus a reference element, all constructed from a single PZT disc and a printed circuit board. Cross-correlations of signals from the array elements with signals from the single reference element provide a measurement of the leak noise passing through the spacecraft skin under the array. A spatial Fourier transform reveals the dominant direction of propagation. Triangulation from multiple sensor locations can be used to find the source of the leak.

  3. Leak in spiral weld in a 16 inches gas pipeline

    Energy Technology Data Exchange (ETDEWEB)

    Fazzini, Pablo G.; Bona, Jeremias de [GIE S.A., Mar del Plata (Argentina); Otegui, Jose L. [University of Mar del Plata (Argentina)

    2009-07-01

    This paper discusses a failure analysis after a leak in the spiral weld of a 16 inches natural gas pipeline, in service since 1974. The leak was the result of the coalescence of two different defects, on each surface of the pipe wall, located in the center of the inner cord of the helical DSAW weld. Fractographic and metallographic studies revealed that the leak was a combination of three conditions. During fabrication of the pipe, segregation in grain boundary grouped in mid weld. During service, these segregations underwent a process of selective galvanic corrosion. One of these volumetric defects coincided with a tubular pore in the outer weld. Pigging of the pipeline in 2005 for cleaning likely contributed to the increase of the leak flow, when eliminating corrosion product plugs. Although these defects are likely to repeat, fracture mechanics shows that a defect of this type is unlikely to cause a blowout. (author)

  4. Treatment of cerebrospinal fluid leak after spine surgery

    Directory of Open Access Journals (Sweden)

    Zhao Fang

    2017-04-01

    Full Text Available Owing to the complexity of spinal surgery, there is a great prevalence of dural tear causing cerebrospinal fluid (CSF leakage. Many studies focused on suture repair for dural tear to stop CSF leak. Now some new treatment strategies have shown a promising effect that is listed as follows: 1 creating watertight dural closure to stop CSF leak with the help of dural substitute material; and 2 retarding CSF leak by changing pressure difference, including reducing the subarachnoid fluid pressure, increasing the epidural space pressure and both. In fact several methods mentioned above are usually combined to treat CSF leak. However, no update review summarized the relevant studies implemented in recent years. In this review, the authors would compare the effects of different dural closure techniques, and introduce the latest treatment methods and mechanisms.

  5. Locating Leaks with TrustRank Algorithm Support

    National Research Council Canada - National Science Library

    Luísa Ribeiro; Joaquim Sousa; Alfeu Sa Marques; Nuno E Simões

    2015-01-01

      This paper presents a methodology to quantify and to locate leaks. The original contribution is the use of a tool based on the TrustRank algorithm for the selection of nodes for pressure monitoring...

  6. Using additional external inputs to forecast water quality with an artificial neural network for contamination event detection in source water

    Science.gov (United States)

    Schmidt, F.; Liu, S.

    2016-12-01

    Source water quality plays an important role for the safety of drinking water and early detection of its contamination is vital to taking appropriate countermeasures. However, compared to drinking water, it is more difficult to detect contamination events because its environment is less controlled and numerous natural causes contribute to a high variability of the background values. In this project, Artificial Neural Networks (ANNs) and a Contamination Event Detection Process (CED Process) were used to identify events in river water. The ANN models the response of basic water quality sensors obtained in laboratory experiments in an off-line learning stage and continuously forecasts future values of the time line in an on-line forecasting step. During this second stage, the CED Process compares the forecast to the measured value and classifies it as regular background or event value, which modifies the ANN's continuous learning and influences its forecasts. In addition to this basic setup, external information is fed to the CED Process: A so-called Operator Input (OI) is provided to inform about unusual water quality levels that are unrelated to the presence of contamination, for example due to cooling water discharge from a nearby power plant. This study's primary goal is to evaluate how well the OI fits into the design of the combined forecasting ANN and CED Process and to understand its effects on the online forecasting stage. To test this, data from laboratory experiments conducted previously at the School of Environment, Tsinghua University, have been used to perform simulations highlighting features and drawbacks of this method. Applying the OI has been shown to have a positive influence on the ANN's ability to handle a sudden change in background values, which is unrelated to contamination. However, it might also mask the presence of an event, an issue that underlines the necessity to have several instances of the algorithm run in parallel. Other difficulties

  7. Development of Simple Bacterial Biosensor for Phenol Detection in Water at Medium Concentration using Glass Microelectrode

    Directory of Open Access Journals (Sweden)

    Setyawan Purnomo Sakti

    2016-01-01

    Full Text Available Water is one of the most fundamental natural resources in earth. The availability of clean water becomes a global interest. Many human activities result in water pollution. One from many pollution substances in water is phenol. Phenol is a very common residual compound in industrial activity. Extensive use of phenol in industry degrades water quality. Regulation has been set in many countries to prevent further damage to the water resource caused by phenol and limiting phenol concentration in water before released into the environment. Therefor it is importance to develop a sensor which can detect phenol concentration in water to be used as a wastewater quality control system. This paper presents a development of bacterial biosensor using Pseudomonas putida and Pseudomonas fluorescens as a biological sensitive material. The sensor was made from glass micro electrode using Ag/AgCl electrode as reference electrode, silver electrode and cellulose ester. The Pseudomonas putida was entrapped inside the nutrient solution and separated by cellulose ester membrane from water containing phenol. It was found that the Pseudomonas putida in used must be growth in 10 hours to reach its optimum growth condition. Linear relationship between biosensor output voltages to phenol concentration was measured for phenol concentration below 200 ppm. The sensitivity of the developed biosensor was 72mV/ppm for Pseudomonas putida and 68.8 mV/ppm for Pseudomonas fluorescens.

  8. Rapid toxicity detection in water quality control utilizing automated multispecies biomonitoring for permanent space stations

    Science.gov (United States)

    Morgan, E. L.; Young, R. C.; Smith, M. D.; Eagleson, K. W.

    1986-01-01

    The objective of this study was to evaluate proposed design characteristics and applications of automated biomonitoring devices for real-time toxicity detection in water quality control on-board permanent space stations. Simulated tests in downlinking transmissions of automated biomonitoring data to Earth-receiving stations were simulated using satellite data transmissions from remote Earth-based stations.

  9. Immuno-PCR for detection of Giardia lamblia cysts in water.

    Science.gov (United States)

    Deng, Ming Jun; Ji, Xin Cheng; Xiao, Xi Zhi; Sun, Tao; Wu, Zhen Xing; Zheng, Xiao Long; Wang, Qun; Zhu, Lai Hua

    2014-01-01

    Giardia lamblia cysts at low concentrations were detected in water samples using a highly sensitive immunological-PCR (IPCR) method. Magnetic gold particles were precoated with monoclonal anti-Giardia antibodies, and Giardia lamblia cysts ranging from 1 to 100 cysts were diluted in 500 microL of water. A biotinylated detection antibody bound to the G. lamblia cysts was then linked by a streptavidin bridge to biotinylated Giardia-reporter DNA. After extensive washing, reporter DNA was released by denaturation, transferred to PCR tubes, amplified, electrophoresed, and visualized. An optimized immuno-PCR method detected as little as five G. lamblia cysts. To further evaluate the specificity and the clinical application of this IPCR assay for G. lamblia cysts, Entamoeba histolytica and Cryptosporidium parvum were also collected and detected by IPCR. The data demonstrated that this monoclonal antibody-based IPCR method is particularly useful for analysis of environmental water samples in which the densities of G. lamblia cysts is very low, and provides a platform capable of rapid screening of samples from drinking water, wells, rivers, lakes, and recreational swimming pools for trace levels of G. lamblia cysts.

  10. New technologies to detect and monitor Phytophthora ramorum in plant, soil, and water samples

    Science.gov (United States)

    Paul Russell; Nathan McOwen; Robert Bohannon

    2013-01-01

    The focus of our research efforts has been to develop methods to quickly identify plants, soil, and water samples infested with Phytophthora spp., and to rapidly confirm the findings using novel isothermal DNA technologies suitable for field use. These efforts have led to the development of a rapid Immunostrip® that reliably detects...

  11. Prospects for detecting oxygen, water, and chlorophyll on an exo-Earth.

    Science.gov (United States)

    Brandt, Timothy D; Spiegel, David S

    2014-09-16

    The goal of finding and characterizing nearby Earth-like planets is driving many NASA high-contrast flagship mission concepts, the latest of which is known as the Advanced Technology Large-Aperture Space Telescope (ATLAST). In this article, we calculate the optimal spectral resolution R = λ/δλ and minimum signal-to-noise ratio per spectral bin (SNR), two central design requirements for a high-contrast space mission, to detect signatures of water, oxygen, and chlorophyll on an Earth twin. We first develop a minimally parametric model and demonstrate its ability to fit synthetic and observed Earth spectra; this allows us to measure the statistical evidence for each component's presence. We find that water is the easiest to detect, requiring a resolution R ≳ 20, while the optimal resolution for oxygen is likely to be closer to R = 150, somewhat higher than the canonical value in the literature. At these resolutions, detecting oxygen will require approximately two times the SNR as water. Chlorophyll requires approximately six times the SNR as oxygen for an Earth twin, only falling to oxygen-like levels of detectability for a low cloud cover and/or a large vegetation covering fraction. This suggests designing a mission for sensitivity to oxygen and adopting a multitiered observing strategy, first targeting water, then oxygen on the more favorable planets, and finally chlorophyll on only the most promising worlds.

  12. Efficacy of brown sugar flotation and hot water methods for detecting Rhagoletis indifferens (Dipt., Tephritidae) larvae

    Science.gov (United States)

    The brown sugar flotation and hot water methods are accepted procedures for detecting larval western cherry fruit fly, Rhagoletis indifferens Curran, in sweet cherry [Prunus avium (L.) L.] and could be included in a systems approach for showing the absence of larvae in fruit. The methods require cr...

  13. Anaerobic incubation of membrane filter cultures for improved detection of fecal coliforms from recreational waters.

    OpenAIRE

    Doyle, J D; Tunnicliff, B; Brickler, S K; Kramer, R E; Sinclair, N A

    1984-01-01

    Anaerobic incubation of membrane filter cultures significantly enhanced detection of fecal coliforms in surface-water samples from recreational beaches. In contrast to standard aerobic incubation, anaerobic incubation suppressed overgrowth of masking, noncoliform bacteria but did not increase the frequency of fecal coliform recovery.

  14. Hydrogen-bond dynamics in water explored by heterodyne-detected photon echo

    NARCIS (Netherlands)

    Yeremenko, S; Pshenichnikov, MS; Wiersma, DA; Pshenichnikov, Maxim S.

    2003-01-01

    Results of heterodyne-detected photon echo experiments on the OH stretching mode of water are reported and discussed. Two vibrational dynamical processes with time constants of 130 and 900 fs were identified. The former is attributed to bond breaking dynamics of a single hydrogen bond, the latter to

  15. Simultaneous detection of multiple bioactive pollutants using a multiparametric biochip for water quality monitoring.

    Science.gov (United States)

    Guijarro, Christian; Fuchs, Karen; Bohrn, Ulrich; Stütz, Evamaria; Wölfl, Stefan

    2015-10-15

    Water is a renewable resource but yet finite. Its sustainable usage and the maintenance of a good quality are essential for an intact environment, human life and a stable economy. Emerging technologies aim for a continuous monitoring of water quality, overcoming periodic analytical sampling, and providing information on the current state of inshore waters in real time. So does the here presented cell-based sensor system which uses RLC-18 cells (rat liver cells) as the detection layer for the detection of water pollutants. The electrical read-out of the system, cellular metabolism, oxygen consumption and morphological integrity detects small changes in the water quality and indicates a possible physiological damage caused. A generalized functional linear model was implemented in order to regress the chemicals present in the sample on the electrical read-out. The chosen environmental pollutants to test the system were chlorpyrifos, an organophosphate pesticide, and tetrabromobisphenol A, a flame retardant. Each chemical gives a very characteristic response, but the toxicity is mitigated if both chemicals are present at once. This will focus our attention on the statistical approach which is able to discriminate between these pollutants. Copyright © 2015 Elsevier B.V. All rights reserved.

  16. Quantitative PCR detection of Batrachochytrium dendrobatidis DNA from sediments and water

    Science.gov (United States)

    Kirshtein, J.D.; Anderson, C.W.; Wood, J.S.; Longcore, J.E.; Voytek, M.A.

    2007-01-01

    The fungal pathogen Batrachochytrium dendrobatidis (Bd) causes chytridiomycosis, a disease implicated in amphibian declines on 5 continents. Polymerase chain reaction (PCR) primer sets exist with which amphibians can be tested for this disease, and advances in sampling techniques allow non-invasive testing of animals. We developed filtering and PCR based quantitative methods by modifying existing PCR assays to detect Bd DNA in water and sediments, without the need for testing amphibians; we tested the methods at 4 field sites. The SYBR based assay using Boyle primers (SYBR/Boyle assay) and the Taqman based assay using Wood primers performed similarly with samples generated in the laboratory (Bd spiked filters), but the SYBR/Boyle assay detected Bd DNA in more field samples. We detected Bd DNA in water from 3 of 4 sites tested, including one pond historically negative for chytridiomycosis. Zoospore equivalents in sampled water ranged from 19 to 454 l-1 (nominal detection limit is 10 DNA copies, or about 0.06 zoospore). We did not detect DNA of Bd from sediments collected at any sites. Our filtering and amplification methods provide a new tool to investigate critical aspects of Bd in the environment. ?? Inter-Research 2007.

  17. Microbial Diagnostic Microarrays for the Detection and Typing of Food- and Water-Borne (Bacterial) Pathogens

    Science.gov (United States)

    Kostić, Tanja; Sessitsch, Angela

    2011-01-01

    Reliable and sensitive pathogen detection in clinical and environmental (including food and water) samples is of greatest importance for public health. Standard microbiological methods have several limitations and improved alternatives are needed. Most important requirements for reliable analysis include: (i) specificity; (ii) sensitivity; (iii) multiplexing potential; (iv) robustness; (v) speed; (vi) automation potential; and (vii) low cost. Microarray technology can, through its very nature, fulfill many of these requirements directly and the remaining challenges have been tackled. In this review, we attempt to compare performance characteristics of the microbial diagnostic microarrays developed for the detection and typing of food and water pathogens, and discuss limitations, points still to be addressed and issues specific for the analysis of food, water and environmental samples. PMID:27605332

  18. Detection of water soluble lectin and antioxidant component from Moringa oleifera seeds.

    Science.gov (United States)

    Santos, A F S; Argolo, A C C; Coelho, L C B B; Paiva, P M G

    2005-03-01

    Seed flour from Moringa oleifera is widely used as a natural coagulant for water treatment in developing countries. Extracts obtained by water soaking of M. oleifera intact seeds were investigated for the presence of lectin, trypsin inhibitor, tannin as well as antioxidant activity. A water soluble M. oleifera lectin (WSMoL) detected was mainly active with rabbit cells at pH 4.5; heat treatment, pH 7.0, fructose and porcine thyroglobulin abolished HA of WSMoL. Trypsin inhibitor or tannins were not detected; the antioxidant component (WSMoAC) reduced 1,1-diphenyl-2-picrylhydrazyl radical (DPPH) was slower than catechin and was thermostable. The extracts showed a primary glycopolypeptide band of Mw 20,000; the main native acidic protein showed hemagglutinating activity. WSMoL may be involved in seed coagulant properties.

  19. Artificial Leaks in Container Closure Integrity Testing: Nonlinear Finite Element Simulation of Aperture Size Originated by a Copper Wire Sandwiched between the Stopper and the Glass Vial.

    Science.gov (United States)

    Nieto, Alejandra; Roehl, Holger; Brown, Helen; Adler, Michael; Chalus, Pascal; Mahler, Hanns-Christian

    2016-01-01

    Container closure integrity (CCI) testing is required by different regulatory authorities in order to provide assurance of tightness of the container closure system against possible contamination, for example, by microorganisms. Microbial ingress CCI testing is performed by incubation of the container closure system with microorganisms under specified testing conditions. Physical CCI uses surrogate endpoints, such as coloration by dye solution ingress or gas flow (helium leakage testing). In order to correlate microbial CCI and physical CCI test methods and to evaluate the methods' capability to detect a given leak, artificial leaks are being introduced into the container closure system in a variety of different ways. In our study, artificial leaks were generated using inserted copper wires between the glass vial opening and rubber stopper. However, the insertion of copper wires introduces leaks of unknown size and shape. With nonlinear finite element simulations, the aperture size between the rubber stopper and the glass vial was calculated, depending on wire diameter and capping force. The dependency of the aperture size on the copper wire diameter was quadratic. With the data obtained, we were able to calculate the leak size and model leak shape. Our results suggest that the size as well as the shape of the artificial leaks should be taken into account when evaluating critical leak sizes, as flow rate does not, independently, correlate to hole size. Capping force also affected leak size. An increase in the capping force from 30 to 70 N resulted in a reduction of the aperture (leak size) by approximately 50% for all wire diameters. From 30 to 50 N, the reduction was approximately 33%. Container closure integrity (CCI) testing is required by different regulatory authorities in order to provide assurance of tightness of the container closure system against contamination, for example, by microorganisms. Microbial ingress CCI testing is performed by incubation of the

  20. Standard practice for leaks using the mass spectrometer leak detector in the detector probe mode

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2011-01-01

    1.1 This practice covers procedures for testing and locating the sources of gas leaking at the rate of 1 × 10−7 Pa m3/s (1 × 10−8 Std cm3/s) or greater. The test may be conducted on any device or component across which a pressure differential of helium or other suitable tracer gas may be created, and on which the effluent side of the leak to be tested is accessible for probing with the mass spectrometer sampling probe. 1.2 Two test methods are described: 1.2.1 Test Method A—Direct probing, and 1.2.2 Test Method B—Accumulation. 1.3 Units—The values stated in either SI or std-cc/sec units are to be regarded separately as standard. The values stated in each system may not be exact equivalents: therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this sta...

  1. Detection of Emerging and Re-Emerging Pathogens in Surface Waters Close to an Urban Area

    Directory of Open Access Journals (Sweden)

    Stefania Marcheggiani

    2015-05-01

    Full Text Available Current knowledge about the spread of pathogens in aquatic environments is scarce probably because bacteria, viruses, algae and their toxins tend to occur at low concentrations in water, making them very difficult to measure directly. The purpose of this study was the development and validation of tools to detect pathogens in freshwater systems close to an urban area. In order to evaluate anthropogenic impacts on water microbiological quality, a phylogenetic microarray was developed in the context of the EU project µAQUA to detect simultaneously numerous pathogens and applied to samples from two different locations close to an urban area located upstream and downstream of Rome in the Tiber River. Furthermore, human enteric viruses were also detected. Fifty liters of water were collected and concentrated using a hollow-fiber ultrafiltration approach. The resultant concentrate was further size-fractionated through a series of decreasing pore size filters. RNA was extracted from pooled filters and hybridized to the newly designed microarray to detect pathogenic bacteria, protozoa and toxic cyanobacteria. Diatoms as indicators of the water quality status, were also included in the microarray to evaluate water quality. The microarray results gave positive signals for bacteria, diatoms, cyanobacteria and protozoa. Cross validation of the microarray was performed using standard microbiological methods for the bacteria. The presence of oral-fecal transmitted human enteric-viruses were detected using q-PCR. Significant concentrations of Salmonella, Clostridium, Campylobacter and Staphylococcus as well as Hepatitis E Virus (HEV, noroviruses GI (NoGGI and GII (NoGII and human adenovirus 41 (ADV 41 were found in the Mezzocammino site, whereas lower concentrations of other bacteria and only the ADV41 virus was recovered at the Castel Giubileo site. This study revealed that the pollution level in the Tiber River was considerably higher downstream rather than

  2. Early Water Stress Detection Using Leaf-Level Measurements of Chlorophyll Fluorescence and Temperature Data

    Directory of Open Access Journals (Sweden)

    Zhuoya Ni

    2015-03-01

    Full Text Available The purpose of this paper was to investigate the early water stress in maize using leaf-level measurements of chlorophyll fluorescence and temperature. In this study, a series of diurnal measurements, such as leaf chlorophyll fluorescence (Fs, leaf spectrum, temperature and photosynthetically active radiation (PAR, were conducted for maize during gradient watering and filled watering experiments. Fraunhofer Line Discriminator methods (FLD and 3FLD were used to obtain fluorescence from leaves spectrum. This simulated work using the SCOPE model demonstrated the variations in fluorescence and temperature in stress levels expressed by different stress factors. In the field measurement, the gradient experiment revealed that chlorophyll fluorescence decreased for plants with water stress relative to well-water plants and Tleaf-Tair increased; the filled watering experiment stated that chlorophyll fluorescence of maize under water stress were similar to those of maize under well-watering condition. In addition, the relationships between the Fs, retrieved fluorescence, Tleaf-Tair and water content were analyzed. The Fs determination resulted to the best coefficients of determination for the normalized retrieved fluorescence FLD/PAR (R2 = 0.54, Tleaf-Tair (R2 = 0.48 and water content (R2 = 0.71. The normalized retrieved fluorescence yielded a good coefficient of determination for Tleaf-Tair (R2 = 0.48. This study demonstrated that chlorophyll fluorescence could reflect variations in the physiological states of plants during early water stress, and leaf temperature confirmed the chlorophyll fluorescence analysis results and improved the accuracy of the water stress detection.

  3. PCR detection of specific pathogens in water: a risk-based analysis.

    Science.gov (United States)

    Loge, Frank J; Thompson, Donald E; Call, Douglas R

    2002-06-15

    The relative concentration of pathogens in water samples collected from storm drains and adjacent surfaces was evaluated using established PCR-based protocols. Out of the 58 samples collected from 21 different storm drains, 22% were PCR positive for Escherichia coli ETEC, Salmonella, or adenovirus. The risk of swimming related illnesses associated with detection of E. coli ETEC and Salmonella ranged from 0.39 to 30:100 000 and 0.3-25:1000, respectively. The detection limit corresponding to a negative-PCR result was evaluated in reference to water quality standards developed using a risk-based approach that integrates human dose-response data with acceptable levels of risk promulgated by the U.S. EPA for recreational contact. The percent of samples with an acceptable detection limit ranged from 0% for Giardia lamblia and Shigella to 100% for E. coli ETEC. The principal factor influencing the detection limit of G. lamblia and Shigella was sample volume. The principal factor influencing the detection limit of the remaining bacteria and protozoa, including E. coli O157:H7, Salmonella, and Cryptosporidium parvum, was the presence of inhibitory compounds in the purified nucleic acid extracts. Both recovery and inhibition adversely impacted the detection limit of viruses. Ambient water quality standards based on the occurrence of specific pathogens enumerated with PCR-based assays could serve as a method of evaluating the biological quality of water but only after significant improvements in filtration and purification protocols. The risk-based methodology developed in this study can be used to evaluate future improvements in filtration and purification protocols.

  4. Release of Gd-ions from peralkaline borosilicate glass in pure water for neutrino detection in Water-Cherenkov Detectors

    Science.gov (United States)

    Dongol, R.; Sundaram, S. K.

    2017-09-01

    The addition of Gadolinium (Gd)-based salt, specially GdCl3, in the Water Cherenkov Detectors (WCDs) enhances the sensitivity to neutrino detection. However, the unwanted Cl-based byproducts, significantly reduces the transparency of water and sensitivity of WCDs. An alternative method, to introduce Gd-ions in the WCDs, is through Gd-release from a custom designed Gd-doped glass, when in contact with water. This can potentially eliminate the use of Gd-based salts and byproducts. In this work, we report the Gd-ions release for a Gd-doped peralkaline (Na/Al > 1) borosilicate glass, which closely represents photomultiplier tube (PMT) glass composition used in WCDs. The purpose of the paper is to show that the Gd-ion release from a custom designed glass in the form of beads or powders is feasible and could be used as a controlled Gd-source in future WCDs to enhance neutrino detection. In addition, we present our results of Gd-solubility in the base glass composition.

  5. Protecting drinking water: Rapid detection of human fecal contamination, injured and non-culturable pathogenic microbes in water systems

    Energy Technology Data Exchange (ETDEWEB)

    White, D.C.; Nivens, D.E.; Arrage, A.A.; Appelgate, B.M.; Reardon, S.R.; Sayler, G.S.

    1996-05-01

    The rapid, potentially-automatable extraction of filter retentates has allowed quantitative detection of the unique biomarker for human fecal contamination, coprostanol, and the signature lipid biomarkers for total cellular biomass, viable cellular biomass, lipopolysaccharide (endotoxin). This method may be integrated with DNA based gene probe analysis for specific strains and enzyme activities. Not only does the analysis provide for detection of injured and non-culturable microbes but it also provides biomarkers characteristic of microbes exposed to biocides and disinfectants that can be utilized to monitor effectiveness of water mitigation/treatment. The analysis schemes involve filtration of the water or direct extraction of biofilms in sidestream chambers, supercritical fluid and/or liquid extraction, derivatization, and analysis of ``signature`` patterns by gas chromatography/mass spectrometry. Signature lipid biomarkers of interest are diglycerides, steroids including coprostanol and its isomers, poly-{beta}- hydroxyalcanoates (PHA), phospholipid ester-linked fatty acids (PLFA), and the lipopolysaccharide lipid A hydroxy fatty acids. PLFA found in polar lipid fractions estimate total viable cellular biomass, whereas the total cellular biomass can be calculated from diglyceride/phospholipid ester-linked fatty acids ratios. Furthermore, direct evidence of mitigation/treatment effectiveness can be ascertained by detection of diglycerides, respiratory quinones, PHA, and PLFA markers indicative of metabolic stress and toxicity such as trans monoenoic PLFA as well as oxirane and dicarboxylic fatty acids derived from the PLFA.

  6. Detection of Metabolic Fluxes of O and H Atoms into Intracellular Water in Mammalian Cells

    Science.gov (United States)

    Kreuzer, Helen W.; Quaroni, Luca; Podlesak, David W.; Zlateva, Theodora; Bollinger, Nikki; McAllister, Aaron; Lott, Michael J.; Hegg, Eric L.

    2012-01-01

    Metabolic processes result in the release and exchange of H and O atoms from organic material as well as some inorganic salts and gases. These fluxes of H and O atoms into intracellular water result in an isotopic gradient that can be measured experimentally. Using isotope ratio mass spectroscopy, we revealed that slightly over 50% of the H and O atoms in the intracellular water of exponentially-growing cultured Rat-1 fibroblasts were isotopically distinct from growth medium water. We then employed infrared spectromicroscopy to detect in real time the flux of H atoms in these same cells. Importantly, both of these techniques indicate that the H and O fluxes are dependent on metabolic processes; cells that are in lag phase or are quiescent exhibit a much smaller flux. In addition, water extracted from the muscle tissue of rats contained a population of H and O atoms that were isotopically distinct from body water, consistent with the results obtained using the cultured Rat-1 fibroblasts. Together these data demonstrate that metabolic processes produce fluxes of H and O atoms into intracellular water, and that these fluxes can be detected and measured in both cultured mammalian cells and in mammalian tissue. PMID:22848359

  7. First detection of tidal behaviour in polar mesospheric water vapour by ground based microwave spectroscopy

    Directory of Open Access Journals (Sweden)

    K. Hallgren

    2012-04-01

    Full Text Available Mesospheric water vapour has been observed above ALOMAR in northern Norway (69° N 16° E by our group since 1995 using a 22 GHz ground based microwave spectrometer. A new instrument with higher sensitivity, providing a much better time resolution especially in the upper mesosphere, was installed in May 2008. The time resolution is high enough to provide observations of daily variations in the water vapour mixing ratio. We present the first ground based detections of tidal behaviour in the polar middle atmospheric water vapour distribution.

    Diurnal and semidiurnal variations of water vapour have been observed and due to the long chemical lifetime of water they are assumed to be caused by changing wind patterns which transport water-rich or poor air into the observed region. The detected tidal behaviour does not follow any single other dynamical field but is instead assumed to be a result of the different wind components.

    Both the diurnal and semidiurnal amplitude and phase components are resolved. The former shows a stable seasonal behaviour consistent with earlier observations of wind fields and model calculations, whereas the latter appears more complex and no regular behaviour has so far been observed.

  8. Detecting leaf pulvinar movements on NDVI time series of desert trees: a new approach for water stress detection.

    Science.gov (United States)

    Chávez, Roberto O; Clevers, Jan G P W; Verbesselt, Jan; Naulin, Paulette I; Herold, Martin

    2014-01-01

    Heliotropic leaf movement or leaf 'solar tracking' occurs for a wide variety of plants, including many desert species and some crops. This has an important effect on the canopy spectral reflectance as measured from satellites. For this reason, monitoring systems based on spectral vegetation indices, such as the normalized difference vegetation index (NDVI), should account for heliotropic movements when evaluating the health condition of such species. In the hyper-arid Atacama Desert, Northern Chile, we studied seasonal and diurnal variations of MODIS and Landsat NDVI time series of plantation stands of the endemic species Prosopis tamarugo Phil., subject to different levels of groundwater depletion. As solar irradiation increased during the day and also during the summer, the paraheliotropic leaves of Tamarugo moved to an erectophile position (parallel to the sun rays) making the NDVI signal to drop. This way, Tamarugo stands with no water stress showed a positive NDVI difference between morning and midday (ΔNDVI mo-mi) and between winter and summer (ΔNDVI W-S). In this paper, we showed that the ΔNDVI mo-mi of Tamarugo stands can be detected using MODIS Terra and Aqua images, and the ΔNDVI W-S using Landsat or MODIS Terra images. Because pulvinar movement is triggered by changes in cell turgor, the effects of water stress caused by groundwater depletion can be assessed and monitored using ΔNDVI mo-mi and ΔNDVI W-S. For an 11-year time series without rainfall events, Landsat ΔNDVI W-S of Tamarugo stands showed a positive linear relationship with cumulative groundwater depletion. We conclude that both ΔNDVI mo-mi and ΔNDVI W-S have potential to detect early water stress of paraheliotropic vegetation.

  9. Detecting leaf pulvinar movements on NDVI time series of desert trees: a new approach for water stress detection.

    Directory of Open Access Journals (Sweden)

    Roberto O Chávez

    Full Text Available Heliotropic leaf movement or leaf 'solar tracking' occurs for a wide variety of plants, including many desert species and some crops. This has an important effect on the canopy spectral reflectance as measured from satellites. For this reason, monitoring systems based on spectral vegetation indices, such as the normalized difference vegetation index (NDVI, should account for heliotropic movements when evaluating the health condition of such species. In the hyper-arid Atacama Desert, Northern Chile, we studied seasonal and diurnal variations of MODIS and Landsat NDVI time series of plantation stands of the endemic species Prosopis tamarugo Phil., subject to different levels of groundwater depletion. As solar irradiation increased during the day and also during the summer, the paraheliotropic leaves of Tamarugo moved to an erectophile position (parallel to the sun rays making the NDVI signal to drop. This way, Tamarugo stands with no water stress showed a positive NDVI difference between morning and midday (ΔNDVI mo-mi and between winter and summer (ΔNDVI W-S. In this paper, we showed that the ΔNDVI mo-mi of Tamarugo stands can be detected using MODIS Terra and Aqua images, and the ΔNDVI W-S using Landsat or MODIS Terra images. Because pulvinar movement is triggered by changes in cell turgor, the effects of water stress caused by groundwater depletion can be assessed and monitored using ΔNDVI mo-mi and ΔNDVI W-S. For an 11-year time series without rainfall events, Landsat ΔNDVI W-S of Tamarugo stands showed a positive linear relationship with cumulative groundwater depletion. We conclude that both ΔNDVI mo-mi and ΔNDVI W-S have potential to detect early water stress of paraheliotropic vegetation.

  10. Detection of viruses in drinking water by concentration on magnetic iron oxide.

    Science.gov (United States)

    Rao, V C; Waghmare, S V; Lakhe, S B

    1981-09-01

    Discharge of raw domestic wastes containing human enteric viruses into water courses, consumption of untreated water from canals, streams, and shallow wells in villages, and cross-contamination of water in the distribution system because of intermittent water supply in urban areas continue to cause widespread outbreaks of infectious hepatitis in India. To detect a low number of viruses in 50- to 100-liter samples of water, a method was developed with magnetic iron oxide as the virus adsorbent. Poliovirus-seeded dechlorinated tap water, adjusted to pH 3.0 and 0.0005 M AlCl3, was filtered through a 10-g bed of iron oxide sandwiched between two AP20 prefilter pads held in a 142-mm-diameter, stainless-steel holder. Virus was eluted from iron oxide by recirculating three times a 100-ml volume of 3% beef extract, pH 9.0. The eluate was reconcentrated to 5 ml by adjusting to pH 3, adding 1 g of iron oxide, stirring for 30 min, and eluting the readsorbed virus with 5 ml of beef extract, pH 9.0. Virus recovery varied from 60 to 80%. Using the above method, we took a survey of drinking water at three locations in Nagpur during 1976 and found the presence of virus in 7 of 50 samples. The quantity of virus recovered ranged from 1 to 7 plaque-forming units per 30 to 60 liters. Virus was detected in some samples even with residual chlorine. No coliforms were detected in the virus-positive samples.

  11. Intelligence Leaks: What Is the Role of the Leak and the Leaker in U.S. Democracy?

    Science.gov (United States)

    2014-03-01

    repository of leaked documents and other artifacts of the millennial cyber-punk set. The obscure website gained global notoriety for the massive...The Christian Science Monitor, July 25, 2013, sec. NEWS. 90 Joe Wiesenthal, “WikiLeaks Blows the Lid off the Sex Parties and Drug Usage Among...the Saudi Royals,” Business Insider, March 7, 2011, http://www.businessinsider.com/wikileaks-blows-the-lid-off- the-sex-parties-and- drug -usage-among

  12. A biosensor platform for rapid detection of E. coli in drinking water.

    Science.gov (United States)

    Hesari, Nikou; Alum, Absar; Elzein, Mohamad; Abbaszadegan, Morteza

    2016-02-01

    There remains a need for rapid, specific and sensitive assays for the detection of bacterial indicators for water quality monitoring. In this study, a strategy for rapid detection of Escherichia coli in drinking water has been developed. This strategy is based on the use of the substrate 4-methylumbelliferyl-β-d-glucuronide (MUG), which is hydrolyzed rapidly by the action of E. coli β-d-glucuronidase (GUD) enzyme to yield a fluorogenic 4-methylumbelliferone (4-MU) product that can be quantified and related to the number of E. coli cells present in water samples. In this study, the detection time required for the biosensor response ranged between 20 and 120 min, depending on the number of bacteria in the sample. This approach does not need extensive sample processing with a rapid detection capability. The specificity of the MUG substrate was examined in both, pure cultures of non-target bacterial genera such as Klebsiella, Salmonella, Enterobacter and Bacillus. Non-target substrates that included 4-methylumbelliferyl-β-d-galactopyranoside (MUGal) and l-leucine β-naphthylamide aminopeptidase (LLβ-N) were also investigated to identify nonspecific patterns of enzymatic activities in E. coli. GUD activity was found to be specific for E. coli and no further enzymatic activity was detected by other species. In addition, fluorescence assays were performed for the detection of E. coli to generate standard curves; and the sensitivity of the GUD enzymatic response was measured and repeatedly determined to be less than 10 E. coli cells in a reaction vial. The applicability of the method was tested by performing multiple fluorescence assays under pure and mixed bacterial flora in environmental samples. The results of this study showed that the fluorescence signals generated in samples using specific substrate molecules can be utilized to develop a bio-sensing platform for the detection of E. coli in drinking water. Furthermore, this system can be applied independently or

  13. A LOW-COST GPR GAS PIPE & LEAK DETECTOR

    Energy Technology Data Exchange (ETDEWEB)

    David Cist; Alan Schutz

    2005-03-30

    A light-weight, easy to use ground penetrating radar (GPR) system for tracking metal/non-metal pipes has been developed. A pre-production prototype instrument has been developed whose production cost and ease of use should fit important market niches. It is a portable tool which is swept back and forth like a metal detector and which indicates when it goes over a target (metal, plastic, concrete, etc.) and how deep it is. The innovation of real time target detection frees the user from having to interpret geophysical data and instead presents targets as dots on the screen. Target depth is also interpreted automatically, relieving the user of having to do migration analysis. In this way the user can simply walk around looking for targets and, by ''connecting the dots'' on the GPS screen, locate and follow pipes in real time. This is the first tool known to locate metal and non-metal pipes in real time and map their location. This prototype design is similar to a metal detector one might use at the beach since it involves sliding a lightweight antenna back and forth over the ground surface. The antenna is affixed to the end of an extension that is either clipped to or held by the user. This allows him to walk around in any direction, either looking for or following pipes with the antenna location being constantly recorded by the positioning system. Once a target appears on the screen, the user can locate by swinging the unit to align the cursor over the dot. Leak detection was also a central part of this project, and although much effort was invested into its development, conclusive results are not available at the time of the writing of this document. Details of the efforts that were made as a part of this cooperative agreement are presented.

  14. The Assessment of Instruments for Detecting Surface Water Spills Associated with Oil and Gas Operations

    Energy Technology Data Exchange (ETDEWEB)

    Harris, Aubrey E. [West Virginia Univ., Morgantown, WV (United States); National Energy Technology Lab. (NETL), Morgantown, WV (United States); U.S. Bureau of Reclamation, Albuquerque, NM (United States); Hopkinson, Leslie [West Virginia Univ., Morgantown, WV (United States); Soeder, Daniel [National Energy Technology Lab. (NETL), Morgantown, WV (United States)

    2016-12-02

    Surface water and groundwater risks associated with unconventional oil and gas development result from potential spills of the large volumes of chemicals stored on-site during drilling and hydraulic fracturing operations, and the return to the surface of significant quantities of saline water produced during oil or gas well production. To better identify and mitigate risks, watershed models and tools are needed to evaluate the dispersion of pollutants in possible spill scenarios. This information may be used to determine the placement of in-stream water-quality monitoring instruments and to develop early-warning systems and emergency plans. A chemical dispersion model has been used to estimate the contaminant signal for in-stream measurements. Spills associated with oil and gas operations were identified within the Susquehanna River Basin Commission’s Remote Water Quality Monitoring Network. The volume of some contaminants was found to be sufficient to affect the water quality of certain drainage areas. The most commonly spilled compounds and expected peak concentrations at monitoring stations were used in laboratory experiments to determine if a signal could be detected and positively identified using standard water-quality monitoring equipment. The results were compared to historical data and baseline observations of water quality parameters, and showed that the chemicals tested do commonly affect water quality parameters. This work is an effort to demonstrate that hydrologic and water quality models may be applied to improve the placement of in-stream water quality monitoring devices. This information may increase the capability of early-warning systems to alert community health and environmental agencies of surface water spills associated with unconventional oil and gas operations.

  15. Cerebrospinal fluid leaks following spinal or posterior fossa surgery: use of fat grafts for prevention and repair.

    Science.gov (United States)

    Black, P

    2000-01-01

    Cerebrospinal fluid (CSF) leaks are relatively common following spinal or posterior fossa surgery. A midline dural tear in the spine is readily repaired by direct application of a suture. However, far-lateral or ventral dural tears are problematic. Fat is an ideal sealant because it is impermeable to water. In this paper the author reports his experience with using fat grafts for the prevention or repair of CSF leaks and proposes a technique in which a large sheet of fat, harvested from the patient's subcutaneous layer, is used to cover not only the dural tear(s) but all of the exposed dura and is tucked into the lateral recess. This procedure prevents CSF from seeping around the fat, which may be tacked to the dura with a few sutures. Fibrin glue is spread on the surface of the fat and is further covered with Surgicel or Gelfoam. For ventral dural tears (associated with procedures in which disc material is excised), fat is packed into the disc space to seal off the ventral dural leak. Leaks in the posterior fossa are managed similarly to those in the spine. Dural suture lines, following suboccipital or spinal intradural exploration, are prophylactically protected from CSF leakage in the same manner. With one exception, 27 dural tears noted during 1650 spinal procedures were successfully repaired using this technique. There was one case of postoperative CSF leakage in 150 cases in which intradural exploration for tumor or other lesions was undertaken. Both postoperative CSF leaks were controlled by applying additional skin sutures. The use of a fat graft is recommended as a rapid, effective means of prevention and repair of CSF leaks following posterior fossa and spinal surgery.

  16. ENVIRONMENTAL MONITORING OF LEAKS USING TIME LAPSED LONG ELECTRODE ELECTRICAL RESISTIVITY

    Energy Technology Data Exchange (ETDEWEB)

    MYERS DA; RUCKER DF; FINK JB; LOKE MH

    2009-12-16

    Highly industrialized areas pose challenges for surface electrical resistivity characterization due to metallic infrastructure. The infrastructure is typically more conductive than the desired targets and will mask the deeper subsurface information. These challenges may be minimized if steel-cased wells are used as long electrodes in the area near the target. We demonstrate a method of using long electrodes to electrically monitor a simulated leak from an underground storage tank with both synthetic examples and a field demonstration. The synthetic examples place a simple target of varying electrical properties beneath a very low resistivity layer. The layer is meant to replicate the effects of infrastructure. Both surface and long electrodes are tested on the synthetic domain. The leak demonstration for the field experiment is simulated by injecting a high conductivity fluid in a perforated well within the S tank farm at Hanford, and the resistivity measurements are made before and after the leak test. All data are processed in four dimensions, where a regularization procedure is applied in both the time and space domains. The synthetic test case shows that the long electrode ERM could detect relative changes in resistivity that are commensurate with the differing target properties. The surface electrodes, on the other hand, had a more difficult time matching the original target's footprint. The field results shows a lowered resistivity feature develop south of the injection site after cessation of the injections. The time lapsed regularization parameter has a strong influence on the differences in inverted resistivity between the pre and post injection datasets, but the interpretation of the target is consistent across all values of the parameter. The long electrode ERM method may provide a tool for near real-time monitoring of leaking underground storage tanks.

  17. Intestinal tissues induce an SNP mutation in Pseudomonas aeruginosa that enhances its virulence: possible role in anastomotic leak.

    Directory of Open Access Journals (Sweden)

    Andrea D Olivas

    Full Text Available The most feared complication following intestinal resection is anastomotic leakage. In high risk areas (esophagus/rectum where neoadjuvant chemoradiation is used, the incidence of anastomotic leaks remains unacceptably high (≈ 10% even when performed by specialist surgeons in high volume centers. The aims of this study were to test the hypothesis that anastomotic leakage develops when pathogens colonizing anastomotic sites become in vivo transformed to express a tissue destroying phenotype. We developed a novel model of anastomotic leak in which rats were exposed to pre-operative radiation as in cancer surgery, underwent distal colon resection and then were intestinally inoculated with Pseudomonas aeruginosa, a common colonizer of the radiated intestine. Results demonstrated that intestinal tissues exposed to preoperative radiation developed a significant incidence of anastomotic leak (>60%; p<0.01 when colonized by P. aeruginosa compared to radiated tissues alone (0%. Phenotype analysis comparing the original inoculating strain (MPAO1- termed P1 and the strain retrieved from leaking anastomotic tissues (termed P2 demonstrated that P2 was altered in pyocyanin production and displayed enhanced collagenase activity, high swarming motility, and a destructive phenotype against cultured intestinal epithelial cells (i.e. apoptosis, barrier function, cytolysis. Comparative genotype analysis between P1 and P2 revealed a single nucleotide polymorphism (SNP mutation in the mexT gene that led to a stop codon resulting in a non-functional truncated protein. Replacement of the mutated mexT gene in P2 with mexT from the original parental strain P1 led to reversion of P2 to the P1 phenotype. No spontaneous transformation was detected during 20 passages in TSB media. Use of a novel virulence suppressing compound PEG/Pi prevented P. aeruginosa transformation to the tissue destructive phenotype and prevented anastomotic leak in rats. This work demonstrates that

  18. Lymphatic Leak Occurring After Surgical Lymph Node Dissection: A Preliminary Study Assessing the Feasibility and Outcome of Lymphatic Embolization

    Energy Technology Data Exchange (ETDEWEB)

    Baek, Yoolim; Won, Je Hwan [Ajou University School of Medicine, Department of Radiology, Ajou University Hospital (Korea, Republic of); Kong, Tae-Wook; Paek, Jiheum; Chang, Suk-Joon; Ryu, Hee-Sug [Ajou University School of Medicine, Department of Obstetrics and Gynecology, Gynecologic Cancer Center (Korea, Republic of); Kim, Jinoo, E-mail: jinoomail@gmail.com [Ajou University School of Medicine, Department of Radiology, Ajou University Hospital (Korea, Republic of)

    2016-12-15

    PurposeTo analyze imaging findings of lymphatic leakage associated with surgical lymph node dissection on lymphangiography and assess the outcome of lymphatic embolization.Materials and MethodsThis retrospective study comprised 21 consecutive patients who were referred for lymphatic intervention between March 2014 and April 2015 due to postsurgical lymphatic leaks. Lymphangiography was performed through inguinal lymph nodes to identify the leak. When a leak was found, lymphatic embolization was performed by fine-needle injection of N-butyl cyanoacrylate into the site of leakage or into an inflow lymphatic vessel or into a pelvic lymph node located below the leakage. Electronic medical records and imaging studies were reviewed to assess the outcome.ResultLymphangiography revealed single or multiple leaks in all but one patient. Lymphatic embolization was performed in 20 patients with leaks. Including the patient who did not undergo embolization, 17 patients (81.0 %) showed initial response to treatment. Three patients underwent repeated embolization with successful results. The overall success rate was 95.2 %. The mean duration of hospitalization after lymphatic intervention was 5.9 days. During a mean follow-up period of 11 months, two patients developed localized swelling in the groin following lipiodol injection. There were no complications related to lymphatic embolization. Three patients were found to have developed small, asymptomatic lymphoceles on CT or MRI that did not require further treatment.ConclusionLymphangiography is useful for detecting lymphatic leakage occurring after lymph node dissection. Furthermore, lymphatic embolization is feasible, effective, and safe for managing leaks demonstrated on lymphangiography.

  19. First Detection of Water Ice and Organics on an Asteroid: A Possible Link to the Origin of Earth's Water

    Science.gov (United States)

    Hargrove, Kelsey D.; Campins, H.; Pinilla-Alonso, N.; Howell, E. S.; Kelley, M. S.; Licandro, J.; Mothédiniz, T.; Fernández, Y.; Ziffer, J.

    2010-05-01

    We report the detection of water ice and organics on the surface of asteroid 24 Themis. Our rotationally-resolved infrared (2-4 µm) spectra of this asteroid indicate that the ice and organics are widespread on its surface. The spectral difference with other asteroids observed in the same manner, makes 24 Themis unique so far. Our identification of water ice and organic compounds on this asteroid agrees with independent results (Rivkin and Emery 2010). At first glance, the presence of any surface ice on 24 Themis, particularly over a significant fraction of its surface, is puzzling because of the instability for exposed water ice at Themis's heliocentric distance ( 3.2 AU). Nevertheless, there are several possible sources for this unstable ice and identifying them is likely to be diagnostic of other processes on primitive asteroids. The presence of water ice on 24 Themis supports the idea that ice sublimation drives the cometary activity in two small members of the Themis dynamical family, labeled "Main Belt comets” by Hsieh and Jewitt (2006). It also helps to address other relevant questions, such as, how abundant is water ice in the outer asteroid belt and where was the "snow” line when the solar system formed? The answers to these questions could transform current views of primitive asteroids, delivery of water and organic molecules to Earth, and models of Solar System formation. This research was published in the April 29, 2010 issue of the journal Nature. Hargrove and Campins are visiting astronomers at the Infrared Telescope Facility (IRTF), which is operated by the University of Hawaii under Cooperative Agreement no. NCC 5-538 with the National Aeronautics and Space Administration

  20. Clustering and Support Vector Regression for Water Demand Forecasting and Anomaly Detection

    Directory of Open Access Journals (Sweden)

    Antonio Candelieri

    2017-03-01

    Full Text Available This paper presents a completely data-driven and machine-learning-based approach, in two stages, to first characterize and then forecast hourly water demand in the short term with applications of two different data sources: urban water demand (SCADA data and individual customer water consumption (AMR data. In the first case, reliable forecasting can be used to optimize operations, particularly the pumping schedule, in order to reduce energy-related costs, while in the second case, the comparison between forecast and actual values may support the online detection of anomalies, such as smart meter faults, fraud or possible cyber-physical attacks. Results are presented for a real case: the water distribution network in Milan.

  1. Near-infrared fluorescent probe for detection of thiophenols in water samples and living cells.

    Science.gov (United States)

    Yu, Dehuan; Huang, Feihu; Ding, Shuangshuang; Feng, Guoqiang

    2014-09-02

    The development of probes for rapid, selective, and sensitive detection of the highly toxic thiophenols is of great importance in both environmental and biological science. Despite the appealing advantages of near-infrared (NIR) fluorescent detection, no NIR fluorescent probes have been reported for thiophenols to date. Using the chemical properties of thiophenols that are able to cleave sulfonamide selectively and efficiently under mild conditions, we herein report a dicyanomethylene-benzopyran (DCMB)-based NIR fluorescent probe for thiophenols. This probe features remarkable large Stokes shift and shows a rapid, highly selective, and sensitive detection process for thiophenols with significant NIR fluorescent turn-on responses. The potential applications of this new NIR fluorescent probe were demonstrated by the quantitative detection of thiophenol in real water samples and by fluorescent imaging of thiophenol in living cells.

  2. Detection of Legionella, L. pneumophila and Mycobacterium Avium Complex (MAC along Potable Water Distribution Pipelines

    Directory of Open Access Journals (Sweden)

    Harriet Whiley

    2014-07-01

    Full Text Available Inhalation of potable water presents a potential route of exposure to opportunistic pathogens and hence warrants significant public health concern. This study used qPCR to detect opportunistic pathogens Legionella spp., L. pneumophila and MAC at multiple points along two potable water distribution pipelines. One used chlorine disinfection and the other chloramine disinfection. Samples were collected four times over the year to provide seasonal variation and the chlorine or chloramine residual was measured during collection. Legionella spp., L. pneumophila and MAC were detected in both distribution systems throughout the year and were all detected at a maximum concentration of 103 copies/mL in the chlorine disinfected system and 106, 103 and 104 copies/mL respectively in the chloramine disinfected system. The concentrations of these opportunistic pathogens were primarily controlled throughout the distribution network through the maintenance of disinfection residuals. At a dead-end and when the disinfection residual was not maintained significant (p < 0.05 increases in concentration were observed when compared to the concentration measured closest to the processing plant in the same pipeline and sampling period. Total coliforms were not present in any water sample collected. This study demonstrates the ability of Legionella spp., L. pneumophila and MAC to survive the potable water disinfection process and highlights the need for greater measures to control these organisms along the distribution pipeline and at point of use.

  3. Detection of fraudulent addition of bovine whey in water buffalo ricotta cheese by isoelectric focusing.

    Science.gov (United States)

    Fuselli, Fabio; Deluca, Anna; Montepeloso, Emanuela A; Ibba, Giulia; Tidona, Flavio; Longo, Lucia; Marianella, Rosa M

    2015-10-01

    Prevention of food fraud in the dairy field is a difficult issue for researchers, industries and policy makers, both for commercial and health reasons. Currently, no analytical method allows detection of the addition of bovine whey to water buffalo ricotta, so this fraudulent practice cannot be prevented. The authors' aim was to develop such a method. The conditions for extraction and purification of denatured ricotta whey proteins, which are unfolded and coagulated by heating during the production process, were optimized. The optimal composition of the polyacrylamide gel (pH range, type and concentration of chemical separator) was first evaluated and then the best conditions to perform the separation by isoelectric focusing were established. The performance of the method (precision, selectivity, robustness, sensibility) was determined. The method was shown to be reliable and robust for detection of the presence of bovine whey added to water buffalo Ricotta at percentages above 5% (v/v). The results suggest that the differences observed between bovine and water buffalo electrophoretic profiles are due to bovine β-lactoglobulin isoform A, which is never detected in water buffalo samples. © 2014 Society of Chemical Industry.

  4. Β-hydroxymyristic acid as a chemical marker to detect endotoxins in dialysis water.

    Science.gov (United States)

    Mishra, Rupesh K; Robert-Peillard, Fabien; Ravier, Sylvain; Coulomb, Bruno; Boudenne, Jean-Luc

    2015-02-01

    An analytical chemical method has been developed for determination of β-hydroxymyristic acid (β-HMA), a component of lipopolysaccharides (LPSs/endotoxins) in dialysis water. In our investigation, the β-HMA component was used as a chemical marker for endotoxin presence in dialysis water because it is available in the molecular subunit (lipid A) and responsible for toxicity. It is the most abundant saturated fatty acid in that subunit. The developed method is based on fluorescence derivatization with 4-nitro-7-piperazino-2,1,3-benzoxadiazole (NBD-PZ). A high-performance liquid chromatographic separation of the β-HMA derivative was achieved using an octadecyl silica column in gradient elution. A wide dynamic range of β-HMA was tested and a calibration curve was constructed with accuracy of 90% and variability of less than 10%. The limits of detection and quantification obtained were 2 and 5μM, respectively. The developed method was applied to detect endotoxins in dialysis water by alkaline hydrolysis of LPS using NaOH (0.25M) at 60°C for 2h. After hydrolysis, free acid was detected as its NBD-PZ derivative using high-performance liquid chromatography/mass spectrometry (HPLC/MS). Good recovery rates ranging from 98 to 105% were obtained for β-HMA in dialysis water. Copyright © 2014 Elsevier Inc. All rights reserved.

  5. Detection of Legionella, L. pneumophila and Mycobacterium avium complex (MAC) along potable water distribution pipelines.

    Science.gov (United States)

    Whiley, Harriet; Keegan, Alexandra; Fallowfield, Howard; Bentham, Richard

    2014-07-18

    Inhalation of potable water presents a potential route of exposure to opportunistic pathogens and hence warrants significant public health concern. This study used qPCR to detect opportunistic pathogens Legionella spp., L. pneumophila and MAC at multiple points along two potable water distribution pipelines. One used chlorine disinfection and the other chloramine disinfection. Samples were collected four times over the year to provide seasonal variation and the chlorine or chloramine residual was measured during collection. Legionella spp., L. pneumophila and MAC were detected in both distribution systems throughout the year and were all detected at a maximum concentration of 103 copies/mL in the chlorine disinfected system and 106, 103 and 104 copies/mL respectively in the chloramine disinfected system. The concentrations of these opportunistic pathogens were primarily controlled throughout the distribution network through the maintenance of disinfection residuals. At a dead-end and when the disinfection residual was not maintained significant (p coliforms were not present in any water sample collected. This study demonstrates the ability of Legionella spp., L. pneumophila and MAC to survive the potable water disinfection process and highlights the need for greater measures to control these organisms along the distribution pipeline and at point of use.

  6. Detection of Nanophyetus salmincola in water, snails, and fish tissues by quantitative polymerase chain reaction

    Science.gov (United States)

    Purcell, Maureen K.; Powers, Rachel L.; Besijn, Bonnie; Hershberger, Paul K.

    2017-01-01

    We report the development and validation of two quantitative PCR (qPCR) assays to detect Nanophyetus salmincola DNA in water samples and in fish and snail tissues. Analytical and diagnostic validation demonstrated good sensitivity, specificity, and repeatability of both qPCR assays. The N. salmincola DNA copy number in kidney tissue was significantly correlated with metacercaria counts based on microscopy. Extraction methods were optimized for the sensitive qPCR detection of N. salmincola DNA in settled water samples. Artificially spiked samples suggested that the 1-cercaria/L threshold corresponded to an estimated log10 copies per liter ≥ 6.0. Significant correlation of DNA copy number per liter and microscopic counts indicated that the estimated qPCR copy number was a good predictor of the number of waterborne cercariae. However, the detection of real-world samples below the estimated 1-cercaria/L threshold suggests that the assays may also detect other N. salmincola life stages, nonintact cercariae, or free DNA that settles with the debris. In summary, the qPCR assays reported here are suitable for identifying and quantifying all life stages of N. salmincola that occur in fish tissues, snail tissues, and water.

  7. Detection of copper ions in drinking water using the competitive adsorption of proteins.

    Science.gov (United States)

    Wang, Ran; Wang, Wei; Ren, Hao; Chae, Junseok

    2014-07-15

    Heavy metal ions, i.e., Cu(2+), are harmful to the environment and our health. In order to detect them, and circumvent or alleviate the weaknesses of existing detecting technologies, we contrive a unique Surface Plasmon Resonance (SPR) biosensor combined with competitive adsorption of proteins, termed the Vroman effect. This approach adopts native proteins (albumin) as bio-receptors that interact with Cu(2+) to be denatured. Denaturation disrupts the conformation of albumin so that it weakens its affinity to adsorb on the sensing surface. Through the competitive adsorption between the denatured albumins and the native ones, the displacement occurs adjacent to the sensing surface, and this process is real-time monitored by SPR, a surface-sensitive label-free biosensor. The affinities of native albumin is significantly higher than that of denatured albumin, demonstrated by measured KD of native and denatured albumin to gold surafce, 5.8±0.2×10(-5) M and 5.4±0.1×10(-4) M, respectively. Using our biosensor, Cu(2+) with concentration down to 0.1mg/L is detected in PBS, tap water, deionized water, and bottled water. The SPR biosensor is characterized for 5 different heavy metal ions, Cu(2+), Fe(3+), Mn(2+), Pb(2+), and Hg(2+), most common heavy metal ions found in tap water. At the maximum contaminant level (MCL) suggested by the United States Environmental Protection Agency (EPA), the SPR biosensor produces 13.5±0.4, 1.5±0.4, 0, 0, and 0 mDeg, respectively, suggesting the biosensor may be used to detect Cu(2+) in tap water samples. Copyright © 2014 Elsevier B.V. All rights reserved.

  8. Detection of meteo-hydrological trends and water resources impacts at the basin scale

    Science.gov (United States)

    Anghileri, Daniela; Pianosi, Francesca; Soncini-Sessa, Rodolfo

    2013-04-01

    Trend detection is a classical topic of time series analysis and has gained renewed interest in the last years in climate change research. When dealing with hydrological time series, trend detection is made more complex by the seasonality and the interannual variability that characterize natural catchments. Furthermore, the impacts of detected hydrological trends on water resources at the catchment scale is a relatively less explored issue, although of high relevance for stakeholders and decision-makers. In this study we address such topics investigating the relation between hydro-climatic trends and their impacts on water resources at the basin scale by application to the regulated Alpine lake Maggiore, at the border between Switzerland and Italy. This case study is particularly interesting because of the relevance of the socio-economic component in the system, especially the issues of flood control and downstream irrigation supply, and the high seasonality and interannual variability of the climatic and hydrological system. We propose several graphical tools to effectively visualize the results of traditional trend detection methods like the Mann-Kendall test and the Sen method, and a novel tool, named Moving Average over Shifting Horizon (MASH), which allows to simultaneously tackle seasonality and interannual variability. We also show and discuss how these tools can be applied to quantify the impacts of the detected meteo-hydrological changes on water resources at the basin scale. In our case study, numerical results demonstrate that significant hydrological trends have occurred in the last 25 years, and that they can be reasonably ascribed to changes in the meteorological regime. The consequences of hydrological changes on water resources, namely flood protection along the lake shores and downstream irrigation supply, are less clear, possibly because of non-linearity and threshold effects.

  9. Extractive scintillating polymer sensors for trace-level detection of uranium in contaminated ground water

    Energy Technology Data Exchange (ETDEWEB)

    Duval, Christine E. [Department of Chemical and Biomolecular Engineering, Clemson University, 127 Earle Hall, Clemson, SC 29634 (United States); DeVol, Timothy A. [Department of Environmental Engineering and Earth Sciences, Clemson University, 342 Computer Court, Anderson, SC 29625 (United States); Husson, Scott M., E-mail: shusson@clemson.edu [Department of Chemical and Biomolecular Engineering, Clemson University, 127 Earle Hall, Clemson, SC 29634 (United States)

    2016-12-01

    This contribution describes the synthesis of robust extractive scintillating resin and its use in a flow-cell detector for the direct detection of uranium in environmental waters. The base poly[(4-methyl styrene)-co-(4-vinylbenzyl chloride)-co-(divinylbenzene)-co-(2-(1-napthyl)-4-vinyl-5-phenyloxazole)] resin contains covalently bound fluorophores. Uranium-binding functionality was added to the resin by an Arbuzov reaction followed by hydrolysis via strong acid or trimethylsilyl bromide (TMSBr)-mediated methanolysis. The resin was characterized by Fourier-transform infrared spectroscopy and spectrofluorometry. Fluorophore degradation was observed in the resin hydrolyzed by strong acid, while the resin hydrolyzed by TMSBr-mediated methanolysis maintained luminosity and showed hydrogen bonding-induced Stokes' shift of ∼100 nm. The flow cell detection efficiency for uranium of the TMSBr-mediated methanolysis resin was evaluated at pH 4, 5 and 6 in DI water containing 500 Bq L{sup −1} uranium-233 and demonstrated flow cell detection efficiencies of 23%, 16% and 7%. Experiments with pH 4, synthetic groundwater with 50 Bq L{sup −1} uranium-233 exhibited a flow cell detection efficiency of 17%. The groundwater measurements show that the resins can concentrate the uranyl cation from waters with high concentrations of competitor ions at near-neutral pH. Findings from this research will lay the groundwork for development of materials for real-time environmental sensing of alpha- and beta-emitting radionuclides. - Highlights: • Extractive scintillating resins synthesized with covalently bound fluor and ligand. • Methylphosphonic acid-derivitized resins characterized for optical properties. • Online detection of uranium in ground water demonstrated at near-neutral pH.

  10. Enteric viruses in surface waters from Argentina: molecular and viable virus detection.

    Science.gov (United States)

    Masachessi, G; Pisano, M B; Prez, V E; Martínez, L C; Michelena, J F; Martínez-Wassaf, M; Giordano, M O; Isa, M B; Pavan, J V; Welter, A; Nates, S V; Ré, V

    2017-12-21

    The water resources contaminated with wastewater are an important source of dissemination of enteric viruses with impact on the health of the populations. The aim of the study was to assess the viral contamination of freshwater from a dam in Argentina, including infectious enterovirus detection, viral RNA amplification and genetic characterization of five enteric viruses associated to diarrhea and hepatitis. Enterovirus infectivity (iEV) was evaluated by cell culture and direct immunofluorescence. Detection of viral genome of rotavirus (RV), human astrovirus (HAstV), norovirus (NoV), hepatitis A (HAV) and hepatitis E (HEV) viruses, was performed by RT-PCR. A total of 48 water samples from 4 monitoring points on the body of the Dam from January to December 2012 and 66 water samples from 3 tourist beaches on the edge of the dam from October 2013 to October 2015 were monthly collected. During the first period of time, the overall viral frequency detection was 52.1% for RVA, 50% for HAstV, 60.4% for NoV, 22.9% for HAV, 2.1% for HEV and 64.6% for iEV. The overall frequency detection for the second sampling was 18.2 % for RV and HAstV, for NoV 31.8%, for HEV 0.76% and for iEV 66.7%. There was no detection of HAV during this period. The genotypes and genogroups detected through the study, correlated to the most common genomic variants associated with human gastrointestinal and hepatitis illness. The results obtained alert the health systems and environmental sanitation in order to make decisions for viral control and prevention in our environment.Importance The study shows the impact of anthropic contamination of one of the most important tourist water resources in our country. This course of recreational water would be a favorable scenario for the infection, as well as a reservoir for the enteric viruses, creating a risk for the population exposed to these waters. The results obtained could alert the health systems and environmental sanitation in order to make decisions

  11. Field portable mobile phone based fluorescence microscopy for detection of Giardia lamblia cysts in water samples

    Science.gov (United States)

    Ceylan Koydemir, Hatice; Gorocs, Zoltan; McLeod, Euan; Tseng, Derek; Ozcan, Aydogan

    2015-03-01

    Giardia lamblia is a waterborne parasite that causes an intestinal infection, known as giardiasis, and it is found not only in countries with inadequate sanitation and unsafe water but also streams and lakes of developed countries. Simple, sensitive, and rapid detection of this pathogen is important for monitoring of drinking water. Here we present a cost-effective and field portable mobile-phone based fluorescence microscopy platform designed for automated detection of Giardia lamblia cysts in large volume water samples (i.e., 10 ml) to be used in low-resource field settings. This fluorescence microscope is integrated with a disposable water-sampling cassette, which is based on a flow-through porous polycarbonate membrane and provides a wide surface area for fluorescence imaging and enumeration of the captured Giardia cysts on the membrane. Water sample of interest, containing fluorescently labeled Giardia cysts, is introduced into the absorbent pads that are in contact with the membrane in the cassette by capillary action, which eliminates the need for electrically driven flow for sample processing. Our fluorescence microscope weighs ~170 grams in total and has all the components of a regular microscope, capable of detecting individual fluorescently labeled cysts under light-emitting-diode (LED) based excitation. Including all the sample preparation, labeling and imaging steps, the entire measurement takes less than one hour for a sample volume of 10 ml. This mobile phone based compact and cost-effective fluorescent imaging platform together with its machine learning based cyst counting interface is easy to use and can even work in resource limited and field settings for spatio-temporal monitoring of water quality.

  12. Picogram per liter detections of pyrethroids and organophosphates in surface waters using passive sampling.

    Science.gov (United States)

    Moschet, Christoph; Vermeirssen, Etiënne L M; Seiz, Remo; Pfefferli, Hildegard; Hollender, Juliane

    2014-12-01

    Pyrethroids and organophosphates are among the most toxic insecticides for aquatic organisms, leading to annual-average environmental quality standards (AA-EQS) in the picogram per liter range in surface waters. For monitoring purposes, it is therefore crucial to develop very sensitive analytical methods. Until now, it is very difficult to reach detection limits at or below given AA-EQSs. Here, we present a passive sampling method using silicone rubber (SR) sheets for the sampling of ten pyrethroids and two organophosphates in surface waters. An analytical method was developed, optimized and validated for the extraction of the insecticides from the SR sheets by accelerated solvent extraction followed by clean-up on C18 and silica gel and detection with GC-MS/MS in positive ionization mode. Good precision (50%) was observed for all substances, accuracy was between 66% and 139%. Limits of detection between 6 and 200 pg/L were achieved for all substances in surface waters using average sampling rates for PCBs and PAHs. The lack of substance-specific sampling rates and missing performance reference compounds led to an uncertainty in the concentration estimation of factor three in both directions. In a large field study, comprising 40 environmental samples from nine Swiss rivers, eight out of 12 substances were detected (most frequently: chlorpyrifos, cypermethrin). Most of the estimated organophosphate concentrations were between 0.1 and 1 ng/L, most pyrethroid detections below 0.1 ng/L. Four substances (chlorpyrifos-methyl, cypermethrin, deltamethrin and lambda-cyhalothrin) showed exceedances of their respective AA-EQS in multiple samples, also when the uncertainties in the concentration estimation were considered. As pyrethroid and organophosphate detection by SR passive sampling is very practicable and allows sensitive analysis, it has the potential to become a new tool in the monitoring of non-polar pesticides. Copyright © 2014 Elsevier Ltd. All rights reserved.

  13. Detection of solar wind-produced water in irradiated rims on silicate minerals.

    Science.gov (United States)

    Bradley, John P; Ishii, Hope A; Gillis-Davis, Jeffrey J; Ciston, James; Nielsen, Michael H; Bechtel, Hans A; Martin, Michael C

    2014-02-04

    The solar wind (SW), composed of predominantly ∼1-keV H(+) ions, produces amorphous rims up to ∼150 nm thick on the surfaces of minerals exposed in space. Silicates with amorphous rims are observed on interplanetary dust particles and on lunar and asteroid soil regolith grains. Implanted H(+) may react with oxygen in the minerals to form trace amounts of hydroxyl (-OH) and/or water (H2O). Previous studies have detected hydroxyl in lunar soils, but its chemical state, physical location in the soils, and source(s) are debated. If -OH or H2O is generated in rims on silicate grains, there are important implications for the origins of water in the solar system and other astrophysical environments. By exploiting the high spatial resolution of transmission electron microscopy and valence electron energy-loss spectroscopy, we detect water sealed in vesicles within amorphous rims produced by SW irradiation of silicate mineral grains on the exterior surfaces of interplanetary dust particles. Our findings establish that water is a byproduct of SW space weathering. We conclude, on the basis of the pervasiveness of the SW and silicate materials, that the production of radiolytic SW water on airless bodies is a ubiquitous process throughout the solar system.

  14. Detection of Legionella spp. from Domestic Water in the Prefecture of Arta, Greece

    Directory of Open Access Journals (Sweden)

    Dimitra Dimitriadi

    2014-01-01

    Full Text Available The aim of this research was the isolation of Legionella spp. from domestic water supply networks in the Prefecture of Arta. A total of 100 water samples, from 25 houses, were collected. Half of the samples concerned the cold water and half the hot water supply. Purpose was to detect colonization of the water networks with Legionella spp. >500 cfu/L by using the method of filtration (ISO 11731. Out of 100 samples, 6 samples from 3 houses were positive for Legionella spp. Legionella pneumophila serogroup 2–14 was isolated in 5 of 6 samples, whereas in the sixth sample Legionella anisa was identified. Only three of the samples had residual chloride over 0.2 mg/L, rate which is necessary for potable water, according to the Greek hygienic practice. Concerning the temperature of hot water, the mean temperature of the negative for Legionella samples was higher compared to the mean temperature of the positive for Legionella samples (49.9°C versus 45.5°C. It is estimated that there is risk of infection through the use of showers. The low concentration of chloride and the temperature, which was found within the limits favorable to developing Legionella spp. (20–45°C, provide fertile ground for proliferation of the bacteria.

  15. Evaluation of immunomagnetic separation for the detection of Salmonella in surface waters by polymerase chain reaction.

    Science.gov (United States)

    Hsu, Chao-Yu; Hsu, Bing-Mu; Chang, Tien-Yu; Hsu, Tsui-Kang; Shen, Shu-Min; Chiu, Yi-Chou; Wang, Hung-Jen; Ji, Wen-Tsai; Fan, Cheng-Wei; Chen, Jyh-Larng

    2014-09-19

    Salmonella spp. is associated with fecal pollution and capable of surviving for long periods in aquatic environments. Instead of the traditional, time-consuming biochemical detection, polymerase chain reaction (PCR) allows rapid identification of Salmonella directly concentrated from water samples. However, prevalence of Salmonella may be underestimated because of the vulnerability of PCR to various environmental chemicals like humic acid, compounded by the fact that various DNA polymerases have different susceptibility to humic acid. Because immunomagnetic separation (IMS) theoretically could isolate Salmonella from other microbes and facilitate removal of aquatic PCR inhibitors of different sizes, this study aims to compare the efficiency of conventional PCR combined with immunomagnetic separation (IMS) for Salmonella detection within a moderately polluted watershed. In our study, the positive rate was increased from 17.6% to 47% with nearly ten-fold improvement in the detection limit. These results suggest the sensitivity of Salmonella detection could be enhanced by IMS, particularly in low quality surface waters. Due to its effects on clearance of aquatic pollutants, IMS may be suitable for most DNA polymerases for Salmonella detection.

  16. Evaluation of Immunomagnetic Separation for the Detection of Salmonella in Surface Waters by Polymerase Chain Reaction

    Directory of Open Access Journals (Sweden)

    Chao-Yu Hsu

    2014-09-01

    Full Text Available Salmonella spp. is associated with fecal pollution and capable of surviving for long periods in aquatic environments. Instead of the traditional, time-consuming biochemical detection, polymerase chain reaction (PCR allows rapid identification of Salmonella directly concentrated from water samples. However, prevalence of Salmonella may be underestimated because of the vulnerability of PCR to various environmental chemicals like humic acid, compounded by the fact that various DNA polymerases have different susceptibility to humic acid. Because immunomagnetic separation (IMS theoretically could isolate Salmonella from other microbes and facilitate removal of aquatic PCR inhibitors of different sizes, this study aims to compare the efficiency of conventional PCR combined with immunomagnetic separation (IMS for Salmonella detection within a moderately polluted watershed. In our study, the positive rate was increased from 17.6% to 47% with nearly ten-fold improvement in the detection limit. These results suggest the sensitivity of Salmonella detection could be enhanced by IMS, particularly in low quality surface waters. Due to its effects on clearance of aquatic pollutants, IMS may be suitable for most DNA polymerases for Salmonella detection.

  17. Detection of Oil Product on the Water Surface with Thermal Infrared Camera

    Directory of Open Access Journals (Sweden)

    Kristina Pilžis

    2017-09-01

    Full Text Available From all existing remote detectors infrared sensors are the cheapest and most widely used. In this article described experiment was done to determine if it is possible to detected oil products on the water surface using thermal infrared camera. This hypothesis was confirmed – thickest layer of used oil product appeared hotter than water. Also, it was found that temperatures of oil product on the surface directly depend on the air temperature. However, clouds have a significant effect on efficiency of this remote sensing method.

  18. Comparison of different selective methods for detection of Listeria species in surface water.

    Science.gov (United States)

    Bernagozzi, M; Sacchetti, R; Polenta, L; Bisbini, P

    1995-12-01

    Tests were carried out to evaluate the efficiency of various combinations of selective enrichment and plating techniques using pure cultures of Listeria monocytogenes, Listeria seeligeri and Listeria innocua in suspension and samples of surface water. The best yields for the various Listeria spp. were obtained after a single passage in LEB (Oxoid) or LEB Buffered (Oxoid) and after using Palcam and Oxford agar (Oxoid). Palcam agar was, however, shown to be the most efficient means of detecting the Listeria spp. in the natural water samples.

  19. Extended-gate organic field-effect transistor for the detection of histamine in water

    Science.gov (United States)

    Minamiki, Tsukuru; Minami, Tsuyoshi; Yokoyama, Daisuke; Fukuda, Kenjiro; Kumaki, Daisuke; Tokito, Shizuo

    2015-04-01

    As part of our ongoing research program to develop health care sensors based on organic field-effect transistor (OFET) devices, we have attempted to detect histamine using an extended-gate OFET. Histamine is found in spoiled or decayed fish, and causes foodborne illness known as scombroid food poisoning. The new OFET device possesses an extended gate functionalized by carboxyalkanethiol that can interact with histamine. As a result, we have succeeded in detecting histamine in water through a shift in OFET threshold voltage. This result indicates the potential utility of the designed OFET devices in food freshness sensing.

  20. The pump and leak steady-state concept with a variety of regulated leak pathways

    DEFF Research Database (Denmark)

    Hoffmann, E K

    2001-01-01

    The paper will reflect on how Ussing has affected my own scientific work and how he created much of the framework within which I have been working. I have used five examples: (i) The first description of a 1:1 exchange diffusion was introduced by Ussing in 1947 and has been found to be of great....... This had a major influence on my later description of a swelling-activated Cl- conductance. (ii) The pump-leak steady-state concept for cell volume control was introduced by Krogh in 1946, but it was developed in detail by Leaf and Ussing in 1959. This concept was the basis for me and others, when we later...... to study ion transport across epithelia. A few results on Cl- transport across the operculum epithelium of the small eurohaline fish Fundulus heteroclitus mounted in small Ussing chambers are presented. (v) Shrinkage-activated Na+ conductance and its possible role in isotonic secretion in frog skin glands...