WorldWideScience

Sample records for water heating

  1. Unitary water-to-air heat pumps

    Energy Technology Data Exchange (ETDEWEB)

    Christian, J.E.

    1977-10-01

    Performance and cost functions for nine unitary water-to-air heat pumps ranging in nominal size from /sup 1///sub 2/ to 26 tons are presented in mathematical form for easy use in heat pump computer simulations. COPs at nominal water source temperature of 60/sup 0/F range from 2.5 to 3.4 during the heating cycle; during the cooling cycle EERs range from 8.33 to 9.09 with 85/sup 0/F entering water source temperatures. The COP and EER values do not include water source pumping power or any energy requirements associated with a central heat source and heat rejection equipment.

  2. Water Replacement Schedules in Heat Stress

    Science.gov (United States)

    Londeree, Ben R.; and others

    1969-01-01

    Although early ingestion of cold water appears to lead to greater relief from heat stress during physical exertion than late ingestion, this difference is reduced toward the end of an hour's work in high heat and humidity. (CK)

  3. Performance analysis of air——water dual source heat pump water heater with heat recovery

    Institute of Scientific and Technical Information of China (English)

    CHEN ZeShao; TAO WenQuan; ZHU YanWen; HU Peng

    2012-01-01

    A new air-water dual source heat pump water heater with heat recovery is proposed.The heat pump system can heat water by using a single air source,a single water source,or air-water dual sources.The water is first pre-heated by waste hot water,then heated by the heat pump.Waste heat is recovered by first preheating the cold water and as water source of the heat pump.According to the correlated formulas of the coefficient of performance of air-source heat pump and water-source heat pump,and the gain coefficient of heat recovery-preheater,the formulas for the coefficient of performance of heat pump in six operating modes are obtained by using the dimensionless correspondence analysis method.The system characteristics of heat absorption and release associated with the heat recovery-preheater are analyzed at different working conditions.The developed approaches can provide reference for the optimization of the operating modes and parameters.The results of analysis and experiments show that the coefficient of performance of the device can reach 4-5.5 in winter,twice as much as air source heat pump water heater.The utilization of waste heat in the proposed system is higher than that in the system which only uses waste water to preheating or as heat source.Thus,the effect of energy saving of the new system is obvious.On the other hand,the dimensionless correspondence analysis method is introduced to performance analysis of the heat pump,which also has theoretical significance and practical value.

  4. Residential CO2 Heat Pump System for Combined Space Heating and Hot Water Heating

    OpenAIRE

    Stene, Jørn

    2004-01-01

    Carbon dioxide (CO2, R-744) has been identified as a promising alternative to conventional working fluids in a number of applications due to its favourable environmental and thermophysical properties. Previous work on residential CO2 heat pumps has been dealing with systems for either space heating or hot water heating, and it was therefore considered interesting to carry out a theoretical and experimental study of residential CO2 heat pump systems for combined space heating and hot water hea...

  5. Basics of Solar Heating & Hot Water Systems.

    Science.gov (United States)

    American Inst. of Architects, Washington, DC.

    In presenting the basics of solar heating and hot water systems, this publication is organized from the general to the specific. It begins by presenting functional and operational descriptions of solar heating and domestic hot water systems, outlining the basic concepts and terminology. This is followed by a description of solar energy utilization…

  6. Potential for solar water heating in Zimbabwe

    NARCIS (Netherlands)

    Batidzirai, B.; Lysen, E.H.; van Egmond, S.; van Sark, W.G.J.H.M.

    2009-01-01

    This paper discusses the economic, social and environmental benefits from using solar water heating (SWH) in Zimbabwe. By comparing different water heating technology usage in three sectors over a 25-year period, the potential of SWH is demonstrated in alleviating energy and economic problems that e

  7. Impacts of Water Quality on Residential Water Heating Equipment

    Energy Technology Data Exchange (ETDEWEB)

    Widder, Sarah H.; Baechler, Michael C.

    2013-11-01

    Water heating is a ubiquitous energy use in all residential housing, accounting for 17.7% of residential energy use (EIA 2012). Today, there are many efficient water heating options available for every fuel type, from electric and gas to more unconventional fuel types like propane, solar, and fuel oil. Which water heating option is the best choice for a given household will depend on a number of factors, including average daily hot water use (total gallons per day), hot water draw patterns (close together or spread out), the hot water distribution system (compact or distributed), installation constraints (such as space, electrical service, or venting accommodations) and fuel-type availability and cost. While in general more efficient water heaters are more expensive than conventional water heating technologies, the savings in energy use and, thus, utility bills can recoup the additional upfront investment and make an efficient water heater a good investment over time in most situations, although the specific payback period for a given installation will vary widely. However, the expected lifetime of a water heater in a given installation can dramatically influence the cost effectiveness and savings potential of a water heater and should be considered, along with water use characteristics, fuel availability and cost, and specific home characteristics when selecting the optimum water heating equipment for a particular installation. This report provides recommendations for selecting and maintaining water heating equipment based on local water quality characteristics.

  8. Is the Water Heating Curve as Described?

    Science.gov (United States)

    Riveros, H. G.; Oliva, A. I.

    2008-01-01

    We analysed the heating curve of water which is described in textbooks. An experiment combined with some simple heat transfer calculations is discussed. The theoretical behaviour can be altered by changing the conditions under which the experiment is modelled. By identifying and controlling the different parameters involved during the heating…

  9. Basic principles of solar water heating

    CSIR Research Space (South Africa)

    Page-Shipp, RJ

    1980-09-10

    Full Text Available This article correctly reflects the principles of Solar Water Heating as they pertain to South African conditions. However, it was written in 1980 and the global energy situation has changed considerably. Furthermore, modern commercial units...

  10. Report on Solar Water Heating Quantitative Survey

    Energy Technology Data Exchange (ETDEWEB)

    Focus Marketing Services

    1999-05-06

    This report details the results of a quantitative research study undertaken to better understand the marketplace for solar water-heating systems from the perspective of home builders, architects, and home buyers.

  11. Residential CO{sub 2} heat pump system for combined space heating and hot water heating

    Energy Technology Data Exchange (ETDEWEB)

    Stene, Joern

    2004-02-01

    Carbon dioxide (CO{sub 2}, R-744) has been identified as a promising alternative to conventional working fluids in a number of applications due to its favourable environmental and thermophysical properties. Previous work on residential CO{sub 2} heat pumps has been dealing with systems for either space heating or hot water heating, and it was therefore considered interesting to carry out a theoretical and experimental study of residential CO{sub 2} heat pump systems for combined space heating and hot water heating - o-called integrated CO{sub 2} heat pump systems. The scope of this thesis is limited to brine-to-water and water-to-water heat pumps connected to low-temperature hydronic space heating systems. The main conclusions are: (1) Under certain conditions residential CO{sub 2} heat pump systems for combined space heating and hot water heating may achieve the same or higher seasonal performance factor (SPF) than the most energy efficient state-of-the-art brine-to-water heat pumps. (2) In contrary to conventional heat pump systems for combined space heating and DHW heating, the integrated CO{sub 2} heat pump system achieves the highest COP in the combined heating mode and the DHW heating mode, and the lowest COP in the space heating mode. Hence, the larger the annual DHW heating demand, the higher the SPF of the integrated CO{sub 2} heat pump system. (3) The lower the return temperature in the space heating system and the lower the DHW storage temperature, the higher the COP of the integrated CO{sub 2} heat pump. A low return temperature in the space heating system also results in a moderate DHW heating capacity ratio, which means that a relatively large part of the annual space heating demand can be covered by operation in the combined heating mode, where the COP is considerably higher than in the space heating mode. (4) During operation in the combined heating mode and the DHW heating mode, the COP of the integrated CO{sub 2} heat pump is heavily influenced by

  12. Performance Analysis of Photovoltaic Water Heating System

    Directory of Open Access Journals (Sweden)

    Tomas Matuska

    2017-01-01

    Full Text Available Performance of solar photovoltaic water heating systems with direct coupling of PV array to DC resistive heating elements has been studied and compared with solar photothermal systems. An analysis of optimum fixed load resistance for different climate conditions has been performed for simple PV heating systems. The optimum value of the fixed load resistance depends on the climate, especially on annual solar irradiation level. Use of maximum power point tracking compared to fixed optimized load resistance increases the annual yield by 20 to 35%. While total annual efficiency of the PV water heating systems in Europe ranges from 10% for PV systems without MPP tracking up to 15% for system with advanced MPP trackers, the efficiency of solar photothermal system for identical hot water load and climate conditions is more than 3 times higher.

  13. Field Performance of Heat Pump Water Heaters in the Northeast

    Energy Technology Data Exchange (ETDEWEB)

    Shapiro, Carl [Consortium for Advanced Residential Buildings, Norwalk, CT (United States); Puttagunta, Srikanth [Consortium for Advanced Residential Buildings, Norwalk, CT (United States)

    2016-02-01

    Heat pump water heaters (HPWHs) are finally entering the mainstream residential water heater market. Potential catalysts are increased consumer demand for higher energy efficiency electric water heating and a new Federal water heating standard that effectively mandates use of HPWHs for electric storage water heaters with nominal capacities greater than 55 gallons. When compared to electric resistance water heating, the energy and cost savings potential of HPWHs is tremendous. Converting all electric resistance water heaters to HPWHs could save American consumers 7.8 billion dollars annually ($182 per household) in water heating operating costs and cut annual residential source energy consumption for water heating by 0.70 quads.

  14. Biocorrosion of evaporators of water/water heat pumps

    Energy Technology Data Exchange (ETDEWEB)

    Denier, P.; Sutter, E.M.M.; Cornet, A. (Ecole Nationale Superieure des Arts et Industries, 67 - Strasbourg (FR))

    1990-12-01

    During the last twenty years, many heat pumps were installed in Alsace (France) using groundwater. It appeared that water contained bacteria able to induce metallic corrosion. Thus, it was necessary to have a better knowledge of the situation. A statistical study on water analysis was realised. There is no noticeable relation between bacterial contamination and water chemistry or geographical location. Most of corrosion origines were - a bad water network conception (erosion, cavitation, oxygen differential cells...) - a bad use of metal coupling (galvanic corrosion). The presence of bacteria generally increases the phenomena described above. Solutions proposed are: PVC casing, stainless steel water pumps, heat pump evaporators in noble alloys or metals, PVC or resines lagging. For the actual set of heat pumps, there are less solutions but in some cases an intermediary exchanger would be a good and easy solution.

  15. Corrosion Fatigue in District Heating Water Tanks

    DEFF Research Database (Denmark)

    Maahn, Ernst Emanuel

    1996-01-01

    Three candidate materials for construction of buffer tanks for district heating water have been tested for corrosion fatigue properties in a district heating water environment. The investigation included Slow Strain Rate Testing of plain tensile specimens, crack initiation testing by corrosion...... fatigue of plain tensile specimens and crack growth rate determination for Compact Tensile Specimens under corrosion fatigue conditions. The three materials are equal with respect to stress corrosion sensibility and crack initiation. Crack growth rate is increased with a factor of 4-6 relative to an inert...

  16. Using geothermal water for greenhouse heating

    Directory of Open Access Journals (Sweden)

    Milojević Svetomir

    2006-01-01

    Full Text Available On construction with dimensions 15 x 5 x 2 m, conditions of temperature transmission and vegetables growth are examined. We have been cultivating pepper, cucumber, small cucumber, tomato, and lattice. Over ground heating has been used, consisting of one bent pipe with radius of 10 mm, in the shape of hairpin along the both sides of the construction. Underground heating consists of six pipes with radius of 20 mm on the depth of 350-400 mm. There have been measured the temperature inside construction, the temperature outside construction, the waterflow, and water temperature flowing into and out of the construction. The approximate heating flow factor K is determined by both the equation: heating balance equation and basic equation for temperature transmition. Vegetable growth has been watching during the period of time from March to November 2005.

  17. Heat Transfer in Directional Water Transport Fabrics

    Directory of Open Access Journals (Sweden)

    Chao Zeng

    2016-10-01

    Full Text Available Directional water transport fabrics can proactively transfer moisture from the body. They show great potential in making sportswear and summer clothing. While moisture transfer has been previously reported, heat transfer in directional water transport fabrics has been little reported in research literature. In this study, a directional water transport fabric was prepared using an electrospraying technique and its heat transfer properties under dry and wet states were evaluated, and compared with untreated control fabric and the one pre-treated with NaOH. All the fabric samples showed similar heat transfer features in the dry state, and the equilibrium temperature in the dry state was higher than for the wet state. Wetting considerably enhanced the thermal conductivity of the fabrics. Our studies indicate that directional water transport treatment assists in moving water toward one side of the fabric, but has little effect on thermal transfer performance. This study may be useful for development of “smart” textiles for various applications.

  18. AWSWAH - the heat pipe solar water heater

    Energy Technology Data Exchange (ETDEWEB)

    Akyurt, M.

    1986-01-01

    An all weather heat pipe solar water heater (AWSWAH) comprising a collector of 4 m/sup 2/ (43 ft/sup 2/) and a low profile water tank of 160 liters (42 gal.) was developed. A single heat pipe consisting of 30 risers and two manifolds in the evaporator and a spiral condenser was incorporated into the AWSWAH. Condensate metering was done by synthetic fiber wicks. The AWSWAH was tested alongside two conventional solar water heaters of identical dimensions, an open loop system and a closed loop system. It was found that the AWSWAH was an average of 50% more effective than the open system in the temperature range 30-90 /sup 0/C (86-194 /sup 0/F). The closed loop system was the least efficient of the three systems.

  19. Multifamily Heat Pump Water Heater Evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Hoeschele, M. [Davis Energy Group, Davis, CA (United States). Alliance for Residential Building Innovation; Weitzel, E. [Davis Energy Group, Davis, CA (United States). Alliance for Residential Building Innovation

    2017-03-03

    Although heat pump water heaters (HPWHs) have gained significant attention in recent years as a high efficiency electric water heating solution for single family homes, central HPWHs for commercial or multi-family applications are not as well documented in terms of measured performance and cost effectiveness. To evaluate this technology, the Alliance for Residential Building Innovation team monitored the performance of a 10.5 ton central HPWH installed on a student apartment building at the West Village Zero Net Energy Community in Davis, California. Monitoring data collected over a 16 month period were then used to validate a TRNSYS simulation model. The TRNSYS model was then used to project performance in different climates using local electric rates. Results of the study indicate that after some initial commissioning issues, the HPWH operated reliably with an annual average efficiency of 2.12 (Coefficient of Performance). The observed efficiency was lower than the unit's rated efficiency, primarily due to the fact that the system rarely operated under steady-state conditions. Changes in the system configuration, storage tank sizing, and control settings would likely improve the observed field efficiency. Modeling results suggest significant energy savings relative to electric storage water heating systems (typical annual efficiencies around 0.90) providing for typical simple paybacks of six to ten years without any incentives. The economics versus gas water heating are currently much more challenging given the current low natural gas prices in much of the country. Increased market size for this technology would benefit cost effectiveness and spur greater technology innovation.

  20. Multifamily Heat Pump Water Heater Evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Hoeschele, M. [Alliance for Residential Building Innovation (ARBI), Davis, CA (United States); Weitzel, E. [Alliance for Residential Building Innovation (ARBI), Davis, CA (United States)

    2013-11-22

    Although heat pump water heaters (HPWHs) have gained significant attention in recent years as a high efficiency electric water heating solution for single family homes, central HPWHs for commercial or multi-family applications are not as well documented in terms of measured performance and cost effectiveness. To evaluate this technology, the Alliance for Residential Building Innovation team monitored the performance of a 10.5 ton central HPWH installed on a student apartment building at the West Village Zero Net Energy Community in Davis, California. Monitoring data collected over a 16 month period were then used to validate a TRNSYS simulation model. The TRNSYS model was then used to project performance in different climates using local electric rates. Results of the study indicate that after some initial commissioning issues, the HPWH operated reliably with an annual average efficiency of 2.12 (Coefficient of Performance). The observed efficiency was lower than the unit's rated efficiency, primarily due to the fact that the system rarely operated under steady-state conditions. Changes in the system configuration, storage tank sizing, and control settings would likely improve the observed field efficiency. Modeling results suggest significant energy savings relative to electric storage water heating systems (typical annual efficiencies around 0.90) providing for typical simple paybacks of six to ten years without any incentives. The economics versus gas water heating are currently much more challenging given the current low natural gas prices in much of the country. Increased market size for this technology would benefit cost effectiveness and spur greater technology innovation.

  1. Multifamily Heat Pump Water Heater Evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Hoeschele, M. [Alliance for Residential Building Innovation (ARBI), Davis, CA (United States); Weitzel, E. [Alliance for Residential Building Innovation (ARBI), Davis, CA (United States)

    2017-03-01

    Although heat pump water heaters (HPWHs) have gained significant attention in recent years as a high efficiency electric water heating solution for single family homes, central HPWHs for commercial or multi-family applications are not as well documented in terms of measured performance and cost effectiveness. To evaluate this technology, the Alliance for Residential Building Innovation team monitored the performance of a 10.5 ton central HPWH installed on a student apartment building at the West Village Zero Net Energy Community in Davis, California. Monitoring data collected over a 16 month period were then used to validate a TRNSYS simulation model. The TRNSYS model was then used to project performance in different climates using local electric rates. Results of the study indicate that after some initial commissioning issues, the HPWH operated reliably with an annual average efficiency of 2.12 (Coefficient of Performance). The observed efficiency was lower than the unit's rated efficiency, primarily due to the fact that the system rarely operated under steady-state conditions. Changes in the system configuration, storage tank sizing, and control settings would likely improve the observed field efficiency. Modeling results suggest significant energy savings relative to electric storage water heating systems (typical annual efficiencies around 0.90) providing for typical simple paybacks of six to ten years without any incentives. The economics versus gas water heating are currently much more challenging given the current low natural gas prices in much of the country. Increased market size for this technology would benefit cost effectiveness and spur greater technology innovation.

  2. Field Monitoring Protocol: Heat Pump Water Heaters

    Energy Technology Data Exchange (ETDEWEB)

    Sparn, B.; Earle, L.; Christensen, D.; Maguire, J.; Wilson, E.; Hancock, E.

    2013-02-01

    This document provides a standard field monitoring protocol for evaluating the installed performance of Heat Pump Water Heaters in residential buildings. The report is organized to be consistent with the chronology of field test planning and execution. Research questions are identified first, followed by a discussion of analysis methods, and then the details of measuring the required information are laid out. A field validation of the protocol at a house near the NREL campus is included for reference.

  3. Field Monitoring Protocol. Heat Pump Water Heaters

    Energy Technology Data Exchange (ETDEWEB)

    Sparn, B. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Earle, L. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Christensen, D. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Maguire, J. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Wilson, E. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Hancock, C. E. [Mountain Energy Partnership, Longmont, CO (United States)

    2013-02-01

    This document provides a standard field monitoring protocol for evaluating the installed performance of Heat Pump Water Heaters in residential buildings. The report is organized to be consistent with the chronology of field test planning and execution. Research questions are identified first, followed by a discussion of analysis methods, and then the details of measuring the required information are laid out. A field validation of the protocol at a house near the NREL campus is included for reference.

  4. Solar Water Heating with Low-Cost Plastic Systems (Brochure)

    Energy Technology Data Exchange (ETDEWEB)

    2012-01-01

    Newly developed solar water heating technology can help Federal agencies cost effectively meet the EISA requirements for solar water heating in new construction and major renovations. This document provides design considerations, application, economics, and maintenance information and resources.

  5. Heat transfer in protein-water interfaces.

    Science.gov (United States)

    Lervik, Anders; Bresme, Fernando; Kjelstrup, Signe; Bedeaux, Dick; Miguel Rubi, J

    2010-02-21

    We investigate using transient non-equilibrum molecular dynamics simulation the temperature relaxation process of three structurally different proteins in water, namely; myoglobin, green fluorescence protein (GFP) and two conformations of the Ca(2+)-ATPase protein. By modeling the temperature relaxation process using the solution of the heat diffusion equation we compute the thermal conductivity and thermal diffusivity of the proteins, as well as the thermal conductance of the protein-water interface. Our results indicate that the temperature relaxation of the protein can be described using a macroscopic approach. The protein-water interface has a thermal conductance of the order of 100-270 MW K(-1) m(-2), characteristic of water-hydrophilic interfaces. The thermal conductivity of the proteins is of the order of 0.1-0.2 W K(-1) m(-1) as compared with approximately 0.6 W K(-1) m(-1) for water, suggesting that these proteins can develop temperature gradients within the biomolecular structures that are larger than those of aqueous solutions. We find that the thermal diffusivity of the transmembrane protein, Ca(2+)-ATPase is about three times larger than that of myoglobin or GFP. Our simulation shows that the Kapitza length of these structurally different proteins is of the order of 1 nm, showing that the protein-water interface should play a major role in defining the thermal relaxation of biomolecules.

  6. Water chemistry in heat and cold supply (district heating/cooling)

    Energy Technology Data Exchange (ETDEWEB)

    Deelen-Bremer, Marga van; Vos, Frank de; Heijboer, Rob [KEMA Nederland B.V. (Netherlands)

    2010-07-01

    District heating is seen as an important pillar in the CO{sub 2} reduction. Since the Kyoto protocol with the target for reduction of greenhouse gases, a renewed interest in district heating is visible. District heating and increasingly district cooling can be used for heating/cooling of houses, but also for large buildings and greenhouses. Combined heat and power (CHP), waste incinerator, but also rest heat of industry can provide the heat for district heating. On the other hand cold surface water, groundwater, but also rest heat can be used for district cooling. With the growing heat/cold supply market, also an even larger growth in cases of damages in district heating systems is wittnessed. Damages were chemistry can play an preventing role. A good conditioning of the district heating water, combined with proper monitoring, will safeguard the integrity of the system. (orig.)

  7. Heat losses through pipe connections in hot water stores

    DEFF Research Database (Denmark)

    Andersen, Elsa; Fan, Jianhua; Furbo, Simon

    2007-01-01

    loss from an ideally insulated pipe connected to the top of a hot water tank is mainly due to a natural convection flow in the pipe, that the heat loss coefficient of pipes connected to the top of a hot water tank is high, and that a heat trap can reduce the heat loss coefficient significantly. Further......The heat loss from pipe connections at the top of hot water storage tanks with and without a heat trap is investigated theoretically and compared to similar experimental investigations. Computational Fluid Dynamics (CFD) is used for the theoretical analysis. The investigations show that the heat...

  8. Heat losses through pipe connections in hot water stores

    DEFF Research Database (Denmark)

    Andersen, Elsa; Fan, Jianhua; Furbo, Simon

    2007-01-01

    loss from an ideally insulated pipe connected to the top of a hot water tank is mainly due to a natural convection flow in the pipe, that the heat loss coefficient of pipes connected to the top of a hot water tank is high, and that a heat trap can reduce the heat loss coefficient significantly. Further......The heat loss from pipe connections at the top of hot water storage tanks with and without a heat trap is investigated theoretically and compared to similar experimental investigations. Computational Fluid Dynamics (CFD) is used for the theoretical analysis. The investigations show that the heat...

  9. Theoretical heating coefficient of a heat pump water heater with heat recovery applied in household bathing room

    Institute of Scientific and Technical Information of China (English)

    KOUGuangxiao; WANGHanqing; GUWeili; KOUJianguo

    2003-01-01

    Presents the components and flow diagram of a heat pump water heater with heat reclaim applied In household bathing room, analyzes its characteristics from thermodynamical principle, calculates its theoretical heating coefficient under different operating conditions. The result shows that the maximum value of its heating coefficient is 12.9 under a typical operating condition.

  10. Refrigerant charge management in a heat pump water heater

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Jie; Hampton, Justin W.

    2016-07-05

    Heat pumps that heat or cool a space and that also heat water, refrigerant management systems for such heat pumps, and methods of managing refrigerant charge. Various embodiments remove idle refrigerant from a heat exchanger that is not needed for transferring heat by opening a refrigerant recovery valve and delivering the idle refrigerant from the heat exchanger to an inlet port on the compressor. The heat exchanger can be isolated by closing an electronic expansion valve, actuating a refrigerant management valve, or both. Refrigerant charge can be controlled by controlling how much refrigerant is drawn from the heat exchanger, by letting some refrigerant back into the heat exchanger, or both. Heat pumps can be operated in different modes of operation, and various components can be interconnected with refrigerant conduit. Some embodiments deliver refrigerant gas to the heat exchanger and drive liquid refrigerant out prior to isolating the heat exchanger.

  11. Potential for solar water heating in Zimbabwe

    Energy Technology Data Exchange (ETDEWEB)

    Batidzirai, Bothwell [Department of Science, Technology and Society, Copernicus Institute for Sustainable Development and Innovation, Utrecht University, Heidelberglaan 2, 3584 CS Utrecht (Netherlands)]|[Department of Fuels and Energy, School of Engineering Science and Technology, Chinhoyi University of Technology, P. Bag 7724, Chinhoyi (Zimbabwe); Lysen, Erik H.; Van Egmond, Sander [Utrecht Centre for Energy Research (UCE), Utrecht University, Heidelberglaan 2, 3584 CS Utrecht (Netherlands); Van Sark, Wilfried G.J.H.M. [Department of Science, Technology and Society, Copernicus Institute for Sustainable Development and Innovation, Utrecht University, Heidelberglaan 2, 3584 CS Utrecht (Netherlands)

    2009-04-15

    This paper discusses the economic, social and environmental benefits from using solar water heating (SWH) in Zimbabwe. By comparing different water heating technology usage in three sectors over a 25-year period, the potential of SWH is demonstrated in alleviating energy and economic problems that energy-importing countries like Zimbabwe are facing. SWH would reduce coincident electricity winter peak demand by 13% and reduce final energy demand by 27%, assuming a 50% penetration rate of SWH potential demand. Up to $250 million can be saved and CO{sub 2} emissions can be reduced by 29% over the 25-year period. Benefits are also present at individual consumer level, for the electricity utility, as well as for society at large. In the case of Zimbabwe, policy strategies that can support renewable energy technologies are already in current government policy, but this political will need to be translated into enhanced practical activities. A multi-stakeholder approach appears to be the best approach to promoting widespread dissemination of SWH technologies. (author)

  12. A heat dissipating model for water cooling garments

    Directory of Open Access Journals (Sweden)

    Yang Kai

    2013-01-01

    Full Text Available A water cooling garment is a functional clothing used to dissipate human body’s redundant energy in extravehicular environment or other hot environment. Its heat dissipating property greatly affects body’s heat balance. In this paper, a heat dissipating model for the water cooling garment is established and verified experimentally using the experimental thermal-manikin.

  13. Research of the heat exchanging processes running in the heating and hot water supply loops of the coil heat exchangers

    Directory of Open Access Journals (Sweden)

    Ірина Геннадіївна Шитікова

    2016-11-01

    Full Text Available The fuel-energy complex research has made it possible to disclose a huge power-saving potential in the municipal heat-and-power engineering. Power-and-resource-saving units and systems are becoming extremely urgent because of the power engineering crisis expansion. The self-adjusting heat supply system from the individual heating points with the heat-accumulating units and coil heat exchangers for independent heating and water supply systems has been examined. Coil heat exchangers are used in municipal heating for heat transfer (e.g. geothermal waters for the independent mains of the heating and hot water supply systems. The heat engineering calculation of the heating and accumulating unit with the coil heat exchanger for independent heat supply systems from individual heater was performed and experimental data were received at the experimental industrial unit under the laboratory conditions. The peculiarities of the flows in the intertubular space, their influence on the heat exchange and temperatures of the first and intermediate mains have been shown. It is important to know the processes running inside the apparatus to be able to improve the technical characteristics of the three-loop coil heat exchanger. The task solution will make it possible to save the materials consumption for the three-loop coil heat exchangers in the future

  14. Low temperature heating and high temperature cooling embedded water based surface heating and cooling systems

    CERN Document Server

    Babiak, Jan; Petras, Dusan

    2009-01-01

    This Guidebook describes the systems that use water as heat-carrier and when the heat exchange within the conditioned space is more than 50% radiant. Embedded systems insulated from the main building structure (floor, wall and ceiling) are used in all types of buildings and work with heat carriers at low temperatures for heating and relatively high temperature for cooling.

  15. Simulation of Heat Transfer of Heating-System and Water Pipelines Under Northern Conditions

    Science.gov (United States)

    Stepanov, A. V.; Egorova, G. N.

    2016-09-01

    A mathematical model of joint laying of water pipelines and of city-block heating-system pipelines is considered. The effect of radiation on the process of combined heat transfer in the heat insulation jacket between the construction elements is investigated. The results of mathematical simulation of heat losses with account of the radiant component are given.

  16. Integration of space heating and hot water supply in low temperature district heating

    DEFF Research Database (Denmark)

    Elmegaard, Brian; Ommen, Torben Schmidt; Markussen, Michael

    2016-01-01

    electric heating and three heat pump solutions applying R134a and R744. The results show that conventional solutions at lowest possible temperature have the highest exergetic efficiency of 28% and lowest annual cost of € 690 for a 159 m2 house. The best low temperature system is an R134a heat pump with hot......District heating may supply many consumers efficiently, but the heat loss from the pipes to the ground is a challenge. The heat loss may be lowered by decreasing the network temperatures for which reason low temperature networks are proposed for future district heating. The heating demand...... of the consumers involves both domestic hot water and space heating. Space heating may be provided at low temperature in low energy buildings. Domestic hot water, however, needs sufficient temperatures to avoid growth of legionella. If the network temperature is below the demand temperature, supplementary heating...

  17. Solar system for domestic hot water and space heating

    Energy Technology Data Exchange (ETDEWEB)

    Weiss, W. [Arbeitsgemeinschaf Erneubare Energie, Gleisdorf (Austria)

    1997-12-31

    The solar thermal markets, different types of solar systems for hot water and space heating, the dimensioning and the components of solar heating systems, the properties of the systems are reviewed in this presentation

  18. Heat Transfer Phenomena in Supercritical Water Nuclear Reactors

    Energy Technology Data Exchange (ETDEWEB)

    Mark H. Anderson; MichaelL. Corradini; Riccardo Bonazza; Jeremy R. Licht

    2007-10-03

    A supercritical water heat transfer facility has been built at the University of Wisconsin to study heat transfer in ancircular and square annular flow channel. A series of integral heat transfer measurements has been carried out over a wide range of heat flux, mas velocity and bulk water temperatures at a pressure of 25 MPa. The circular annular test section geometry is a 1.07 cm diameter heater rod within a 4.29 diameter flow channel.

  19. Integration of space heating and hot water supply in low temperature district heating

    DEFF Research Database (Denmark)

    Elmegaard, Brian; Ommen, Torben Schmidt; Markussen, Michael

    2016-01-01

    is required by the consumer. We study conventional district heating at different temperatures and compare the energy and exergetic efficiency and annual heating cost to solutions that utilize electricity for supplementary heating of domestic hot water in low temperature district heating. This includes direct...... electric heating and three heat pump solutions applying R134a and R744. The results show that conventional solutions at lowest possible temperature have the highest exergetic efficiency of 28% and lowest annual cost of € 690 for a 159 m2 house. The best low temperature system is an R134a heat pump with hot......District heating may supply many consumers efficiently, but the heat loss from the pipes to the ground is a challenge. The heat loss may be lowered by decreasing the network temperatures for which reason low temperature networks are proposed for future district heating. The heating demand...

  20. Installation package for a solar heating and hot water system

    Science.gov (United States)

    1978-01-01

    Development and installation of two commercial solar heating and hot water systems are reported. The systems consist of the following subsystems: collector, storage, transport, hot water, auxiliary energy and controls. General guidelines are provided which may be utilized in development of detailed installation plans and specifications. In addition, operation, maintenance and repair of a solar heating and hot water system instructions are included.

  1. 10 CFR 434.518 - Service water heating.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 3 2010-01-01 2010-01-01 false Service water heating. 434.518 Section 434.518 Energy... RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.518 Service water heating. 518.1The service water loads for Prototype and Reference Buildings are defined in terms of Btu/h per person...

  2. Modeling terahertz heating effects on water

    DEFF Research Database (Denmark)

    Kristensen, Torben T.L.; Withayachumnankul, Withawat; Jepsen, Peter Uhd;

    2010-01-01

    We apply Kirchhoff’s heat equation to model the influence of a CW terahertz beam on a sample of water, which is assumed to be static. We develop a generalized model, which easily can be applied to other liquids and solids by changing the material constants. If the terahertz light source is focused...... down to a spot with a diameter of 0.5 mm, we find that the steadystate temperature increase per milliwatt of transmitted power is 1.8◦C/mW. A quantum cascade laser can produce a CW beam in the order of several milliwatts and this motivates the need to estimate the effect of beam power on the sample...... temperature. For THz time domain systems, we indicate how to use our model as a worst-case approximation based on the beam average power. It turns out that THz pulses created from photoconductive antennas give a negligible increase in temperature. As biotissue contains a high water content, this leads...

  3. An experimental study on recovering heat from domestic drain water

    Science.gov (United States)

    Ramadan, Mohamad; Al Shaer, Ali; Haddad, Ahmad; Khaled, Mahmoud

    2016-07-01

    This paper concerns an experimental study on a system of heat recovery applied to domestic drain water pipes. The concept suggested consists of using the heat still present in the drain water as a preheating/heating source to the cold water supply of the building. To proceed, an appropriate experimental setup is developed and a coil heat exchanger is used as heat transfer device in the recovery system. Several scenarios are simulated and corresponding parameters are recorded and analyzed. It was shown that the suggested recovery concept can considerably preheat the cold water supply and then decrease the energy consumption. Particularly, up to 8.6 kW of heat were recovered when the cold water supply is initially at 3 °C.

  4. Low Temperature District Heating Consumer Unit with Micro Heat Pump for Domestic Hot Water Preparation

    DEFF Research Database (Denmark)

    Zvingilaite, Erika; Ommen, Torben Schmidt; Elmegaard, Brian

    2012-01-01

    In this paper we present and analyse the feasibility of a district heating (DH) consumer unit with micro heat pump for domestic hot water (DHW) preparation in a low temperature (40 °C) DH network. We propose a micro booster heat pump of high efficiency (COP equal to 5,3) in a consumer DH unit...... in order to boost the temperature of the district heating water for heating the DHW. The paper presents the main designs of the suggested system and different alternative micro booster heat pump concepts. Energy efficiency and thermodynamic performance of these concepts are calculated and compared....... The results show that the proposed system has the highest efficiency. Furthermore, we compare thermodynamic and economic performance of the suggested heat pump-based concept with different solutions, using electric water heater. The micro booster heat pump system has the highest annualised investment (390 EUR...

  5. Non-parametric method for separating domestic hot water heating spikes and space heating

    DEFF Research Database (Denmark)

    Bacher, Peder; de Saint-Aubain, Philip Anton; Christiansen, Lasse Engbo;

    2016-01-01

    In this paper a method for separating spikes from a noisy data series, where the data change and evolve over time, is presented. The method is applied on measurements of the total heat load for a single family house. It relies on the fact that the domestic hot water heating is a process generating...... short-lived spikes in the time series, while the space heating changes in slower patterns during the day dependent on the climate and user behavior. The challenge is to separate the domestic hot water heating spikes from the space heating without affecting the natural noise in the space heating...... measurements. The assumption behind the developed method is that the space heating can be estimated by a non-parametric kernel smoother, such that every value significantly above this kernel smoother estimate is identified as a domestic hot water heating spike. First, it is showed how a basic kernel smoothing...

  6. Investigation of a heat storage for a solar heating system for combined space heating and domestic hot water supply for homeowner´s association "Bakken"

    DEFF Research Database (Denmark)

    Vejen, Niels Kristian

    1998-01-01

    A heat storage for a solar heating system for combined space heating and domestic hot water supply was tested in a laboratory test facility.The heat storage consist of a mantle tank with water for the heating system and of a hot water tank, which by means of thermosyphoning is heated by the water...... in the heating system. The heat storage was tested in a heat storage test facility. The most important characteristics of the heat storage were determined by means of the tests and recommendations for the design of the heat storage were given....

  7. Investigation of heat transfer for extruded polymers cooled in water

    CSIR Research Space (South Africa)

    Kumar, R

    2015-10-01

    Full Text Available part, the time taken by PE, PP and PLA to lose heat in water was analyzed theoretically with the help of MATLAB software package by taking into account the density, thermal conductivity, heat transfer coefficient and specific heat. The time taken...

  8. Development of heat pipes for solar water heaters

    Energy Technology Data Exchange (ETDEWEB)

    Akyurt, M.

    1984-01-01

    Numerous heat pipes were designed, manufactured, and filled on a specially developed filling rig. Each heat pipe was incorporated into a prototype solar water heater developed for this purpose, and was tested under actual insolation conditions. An extensive testing program lasting for more than a year revealed that the heat pipes perform satisfactorily as heat transfer elements in solar water heaters. A special heat pipe featuring a compact and effective condenser configuration was also tested. It was observed to likewise exhibit isothermal behavior and hence promised potential for large scale solar applications.

  9. Air-to-water heat pumps for the home

    Energy Technology Data Exchange (ETDEWEB)

    Bodzin, S. [ed.

    1997-07-01

    Heat pump water heaters may be on the rise again. Retrofitters have shied away from this form of water heating due to concerns about cost, moise, efficiency, and maintaenance. Recent advances have overcome some of these problems and are helping the technology find a niche in both hot and cold climates. The topics covered in this article include the following: how heat pump water heaters work; air source from where to where, including air conditioning, heat recovery ventilation, hybrid systems; nuisances; maintenance; costs; to install or not to install; performance: a trick to quantify. 2 figs.

  10. Research and Development Roadmap for Water Heating Technologies

    Energy Technology Data Exchange (ETDEWEB)

    Goetzler, William [Navigant Consulting Inc.; Gagne, Claire [Navigant Consulting Inc.; Baxter, Van D [ORNL; Lutz, James [Lawrence Berkeley National Laboratory (LBNL); Merrigan, Tim [National Renewable Energy Laboratory (NREL); Katipamula, Srinivas [Pacific Northwest National Laboratory (PNNL)

    2011-10-01

    Although water heating is an important energy end-use in residential and commercial buildings, efficiency improvements in recent years have been relatively modest. However, significant advancements related to higher efficiency equipment, as well as improved distribution systems, are now viable. DOE support for water heating research, development and demonstration (RD&D) could provide the impetus for commercialization of these advancements.

  11. Preliminary design package for Sunspot Domestic Hot Water Heating System

    Science.gov (United States)

    1976-01-01

    The design review includes a drawing list, auto-control logic, measurement definitions, and other document pertaining to the solar heated prototype hot water systems and two heat exchangers. The hot water systems consist of the following subsystems: collector, storage, control transport, auxiliary energy, and site data acquisition.

  12. Performance analysis on solar-water compound source heat pump for radiant floor heating system

    Institute of Scientific and Technical Information of China (English)

    曲世林; 马飞; 仇安兵

    2009-01-01

    A solar-water compound source heat pump for radiant floor heating (SWHP-RFH) experimental system was introduced and analyzed. The SWHP-RFH system mainly consists of 11.44 m2 vacuum tube solar collector,1 000 L water tank assisted 3 kW electrical heater,a water source heat pump,the radiant floor heating system with cross-linked polyethylene (PE-X) of diameter 20 mm,temperature controller and solar testing system. The SWHP-RFH system was tested from December to February during the heating season in Beijing,China under different operation situations. The test parameters include the outdoor air temperature,solar radiation intensity,indoor air temperature,radiation floor average surface temperature,average surface temperature of the building envelope,the inlet and outlet temperatures of solar collector,the temperature of water tank,the heat medium temperatures of heat pump condenser side and evaporator side,and the power consumption includes the water source heat pump system,the solar source heat pump system,the auxiliary heater and the radiant floor heating systems etc. The experimental results were used to calculate the collector efficiency,heat pump dynamic coefficient of performance (COP),total energy consumption and seasonal heating performance during the heating season. The results indicate that the performance of the compound source heat pump system is better than that of the air source heat pump system. Furthermore,some methods are suggested to improve the thermal performance of each component and the whole SWHP-RFH system.

  13. Efficient air-water heat pumps for high temperature lift residential heating, including oil migration aspects

    OpenAIRE

    Zehnder, Michele; Favrat, Daniel

    2005-01-01

    This thesis presents a system approach with the aim to develop improved concepts for small capacity, high temperature lift air-water heat pumps. These are intended to replace fuel fired heating systems in the residential sector, which leads to a major reduction of the local greenhouse gas emissions. Unfavorable temperature conditions set by the existing heat distribution systems and by the use of atmospheric air, as the only accessible heat source, have to be overcome. The proposed concepts a...

  14. Absorption type water chiller fired directly by waste heat

    Science.gov (United States)

    Sauer, K. L.; Kalwar, K.

    1982-08-01

    The direct use of waste heat as heating element in a water chiller of the absorption type was studied. The chilled water is used as cooling element in the industrial process, producing the waste heat or for conditioning the workplace or further located places. The heat source is gaseous or liquid. The cooling capacity is in the range from 10 to 120 kW. After reviewing the different absorption systems, LiBr/H20 proved to be the most suitable. The process retained for experimenting was the manufacturing of synthetic materials polymer industry and was tested in two different factories. It is proved that the use of absorption type water chillers is practicable with an efficiency of 10% to 25% of the waste heat energy, but that the existing chillers need extensive conversion for obtaining economical operation when using a low temperature heating source.

  15. Field performance of photovoltaic solar water heating systems

    Energy Technology Data Exchange (ETDEWEB)

    Fanney, A.H.; Dougherty, B.P.; Kramp, K.P. [National Inst. of Standards and Technology, Gaithersburg, MD (United States). Building Environment Div.

    1997-11-01

    Energy consumed for water heating accounts for approximately 17.9 EJ of the energy consumed by residential and commercial buildings. Although there are over 90 million water heaters currently in use within the United States, durability and installation issues as well as initial cost have limited the sales of solar water heaters to less than 1 million units. Durability issues have included freeze and fluid leakage problems, failure of pumps and their associated controllers, the loss of heat transfer fluids under stagnation conditions, and heat exchanger fouling. The installation of solar water heating systems has often proved difficult, requiring roof penetrations for the piping that transports fluid to and from the solar collectors. Fanney and Dougherty have recently proposed and patented a solar water heating system that eliminates the durability and installation problems associated with current solar water heating systems. The system employs photovoltaic modules to generate electrical energy which is dissipated in multiple electric heating elements. A microprocessor controller is used to match the electrical resistance of the load to the operating characteristics of the photovoltaic modules. Although currently more expensive than existing solar hot water systems, photovoltaic solar water heaters offer the promise of being less expensive than solar thermal systems within the next decade. To date, photovoltaic solar water heating systems have been installed at the National Institute of Standards and Technology in Gaithersburg, MD and the Florida Solar Energy Center in Cocoa, FL. This paper will review the technology employed, describe the two photovoltaic solar water heating systems, and present measured performance data.

  16. Measure Guideline: Combined Space and Water Heating Installation and Optimization

    Energy Technology Data Exchange (ETDEWEB)

    Schoenbauer, B. [Univ. of Minnesota, St. Paul, MN (United States). NorthernSTAR Building America Partnership; Bohac, D. [Univ. of Minnesota, St. Paul, MN (United States). NorthernSTAR Building America Partnership; Huelman, P. [Univ. of Minnesota, St. Paul, MN (United States). NorthernSTAR Building America Partnership

    2017-03-03

    Combined space and water heater (combi or combo) systems are defined by their dual functionality. Combi systems provide both space heating and water heating capabilities with a single heat source. This guideline will focus on the installation and operation of residential systems with forced air heating and domestic hot water (DHW) functionality. Past NorthernSTAR research has used a combi system to replace a natural gas forced air distribution system furnace and tank type water heater (Schoenbauer et al. 2012; Schoenbauer, Bohac, and McAlpine 2014). The combi systems consisted of a water heater or boiler heating plant teamed with a hydronic air handler that included an air handler, water coil, and water pump to circulate water between the heating plant and coil. The combi water heater or boiler had a separate circuit for DHW. Past projects focused on laboratory testing, field characterization, and control optimization of combi systems. Laboratory testing was done to fully characterize and test combi system components; field testing was completed to characterize the installed performance of combi systems; and control methodologies were analyzed to understand the potential of controls to simplify installation and design and to improve system efficiency and occupant comfort. This past work was relied upon on to create this measure guideline.

  17. Measure Guideline: Combined Space and Water Heating Installation and Optimization

    Energy Technology Data Exchange (ETDEWEB)

    Schoenbauer, B. [NorthernSTAR Building America Partnership, St. Paul, MN (United States); Bohac, D. [NorthernSTAR Building America Partnership, St. Paul, MN (United States); Huelman, P. [NorthernSTAR Building America Partnership, St. Paul, MN (United States)

    2017-03-01

    Combined space and water heater (combi or combo) systems are defined by their dual functionality. Combi systems provide both space heating and water heating capabilities with a single heat source. This guideline will focus on the installation and operation of residential systems with forced air heating and domestic hot water (DHW) functionality. Past NorthernSTAR research has used a combi system to replace a natural gas forced air distribution system furnace and tank type water heater (Schoenbauer et al. 2012; Schoenbauer, Bohac, and McAlpine 2014). The combi systems consisted of a water heater or boiler heating plant teamed with a hydronic air handler that included an air handler, water coil, and water pump to circulate water between the heating plant and coil. The combi water heater or boiler had a separate circuit for DHW. Past projects focused on laboratory testing, field characterization, and control optimization of combi systems. Laboratory testing was done to fully characterize and test combi system components; field testing was completed to characterize the installed performance of combi systems; and control methodologies were analyzed to understand the potential of controls to simplify installation and design and to improve system efficiency and occupant comfort. This past work was relied upon on to create this measure guideline.

  18. FILM-30: A Heat Transfer Properties Code for Water Coolant

    Energy Technology Data Exchange (ETDEWEB)

    MARSHALL, THERON D.

    2001-02-01

    A FORTRAN computer code has been written to calculate the heat transfer properties at the wetted perimeter of a coolant channel when provided the bulk water conditions. This computer code is titled FILM-30 and the code calculates its heat transfer properties by using the following correlations: (1) Sieder-Tate: forced convection, (2) Bergles-Rohsenow: onset to nucleate boiling, (3) Bergles-Rohsenow: partially developed nucleate boiling, (4) Araki: fully developed nucleate boiling, (5) Tong-75: critical heat flux (CHF), and (6) Marshall-98: transition boiling. FILM-30 produces output files that provide the heat flux and heat transfer coefficient at the wetted perimeter as a function of temperature. To validate FILM-30, the calculated heat transfer properties were used in finite element analyses to predict internal temperatures for a water-cooled copper mockup under one-sided heating from a rastered electron beam. These predicted temperatures were compared with the measured temperatures from the author's 1994 and 1998 heat transfer experiments. There was excellent agreement between the predicted and experimentally measured temperatures, which confirmed the accuracy of FILM-30 within the experimental range of the tests. FILM-30 can accurately predict the CHF and transition boiling regimes, which is an important advantage over current heat transfer codes. Consequently, FILM-30 is ideal for predicting heat transfer properties for applications that feature high heat fluxes produced by one-sided heating.

  19. Retrofitting Combined Space and Water Heating Systems. Laboratory Tests

    Energy Technology Data Exchange (ETDEWEB)

    Schoenbauer, B. [NorthernStar Building America Partnership, St. Paul, MN (United States); Bohac, D. [NorthernStar Building America Partnership, St. Paul, MN (United States); Huelman, P. [NorthernStar Building America Partnership, St. Paul, MN (United States); Olsen, R. [NorthernStar Building America Partnership, St. Paul, MN (United States); Hewett, M. [NorthernStar Building America Partnership, St. Paul, MN (United States)

    2012-10-01

    Better insulated and tighter homes can often use a single heating plant for both space and domestic water heating. These systems, called dual integrated appliances (DIA) or combination systems, can operate at high efficiency and eliminate combustion safety issues associated by using a condensing, sealed combustion heating plant. Funds were received to install 400 DIAs in Minnesota low-income homes. The NorthernSTAR DIA laboratory was created to identify proper system components, designs, operating parameters, and installation procedures to assure high efficiency of field installed systems. Tests verified that heating loads up to 57,000 Btu/hr can be achieved with acceptable return water temperatures and supply air temperatures.

  20. Retrofitting Combined Space and Water Heating Systems: Laboratory Tests

    Energy Technology Data Exchange (ETDEWEB)

    Schoenbauer, B.; Bohac, D.; Huelman, P.; Olson, R.; Hewitt, M.

    2012-10-01

    Better insulated and tighter homes can often use a single heating plant for both space and domestic water heating. These systems, called dual integrated appliances (DIA) or combination systems, can operate at high efficiency and eliminate combustion safety issues associated by using a condensing, sealed combustion heating plant. Funds were received to install 400 DIAs in Minnesota low-income homes. The NorthernSTAR DIA laboratory was created to identify proper system components, designs, operating parameters, and installation procedures to assure high efficiency of field installed systems. Tests verified that heating loads up to 57,000 Btu/hr can be achieved with acceptable return water temperatures and supply air temperatures.

  1. Application of Heat Pump in Cooling Water System of HIRFL

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    Accelerator generates a lot of heat when it is working.It must be cooled by the circulating cooling water.Generally the heat was released to atimosphere by the cooling water tower.Because the heat energy is very huge(about 2M watts for HIRFL),it is big waste and the machine can’t be cooled to appropriate temperature when ambient temperature is high in summer.In order to solve the problems,the heat pump has been used

  2. Solar thermal water heating : an application for Alberta, Canada

    Energy Technology Data Exchange (ETDEWEB)

    Jackman, T. [Simple Solar Heating Ltd., Okotoks, AB (Canada); Lonseth, R.; Lonseth, A.; Jagoda, K. [Mount Royal College, Calgary, AB (Canada)

    2009-07-01

    The use of renewable energy resources is an essential feature in curtailing greenhouse gas (GHG) emissions. This paper discussed solar thermal water heating applications for Alberta. In particular, it presented a case study of the successful commercial application of solar thermal water heating systems in households in the city of Calgary. The system used solar-thermal collectors with heat pipes mounted inside vacuum sealed glass cylinders. The devices collected heat and transferred it to a copper manifold even in extreme winter temperatures. The system included a solar storage tank integrated into a domestic hot water system. The solar fluid circulated through the solar tank. Fresh cold water entered the solar tank when hot water was used in the house in order to be preheated before entering the original water heating tank. A 25 watt pump was mounted in the closed solar loop to circulate the solar heat transfer fluid. An economic analysis demonstrated that a 2-panel system saved the equivalent of 2.4 acres of carbon-absorbing forest and had the same benefit as purchasing a hybrid car. The payback period for the system was 4 years. It was concluded that solar thermal systems are the best renewable energy method for domestic water heating in Calgary. 10 refs., 2 tabs., 5 figs.

  3. Installation of potable water supply and heat supply at base of subsoil water

    Directory of Open Access Journals (Sweden)

    Denysova Alla Evseevna

    2016-01-01

    Full Text Available Removal of groundwater with further use of it for potable water supply and heat supply with the use of heat pump is an important problem. A new revolutionary approach to the decision of energy and water saving that provides rational accommodation of groundwater boreholes ensuring the required flow rate of water through the heat pump evaporator with simultaneously high intensity of heat exchange process is proposed. The method of calculation which allows determining the necessary depth of borehole, quantity of boreholes, in consideration of flow rate and temperature of subsoil water determining capacity of heat pump installation is worked out.

  4. Installation of potable water supply and heat supply at base of subsoil water

    Directory of Open Access Journals (Sweden)

    Denysova Alla Evseevna

    2016-01-01

    Full Text Available Removal of groundwater with further use of it for potable water supply and heat supply with the use of heat pump is an important problem. A new revolutionary approach to the decision of energy and water saving that provides rational accommodation of groundwater boreholes ensuring the required flow rate of water through the heat pump evaporator with simultaneously high intensity of heat exchange process is proposed. The method of calculation which allows determining the necessary depth of borehole, quantity of boreholes, in consideration of flow rate and temperature of subsoil water determining capacity of heat pump installation is worked out.

  5. Low-Cost Solar Water Heating Research and Development Roadmap

    Energy Technology Data Exchange (ETDEWEB)

    Hudon, K.; Merrigan, T.; Burch, J.; Maguire, J.

    2012-08-01

    The market environment for solar water heating technology has changed substantially with the successful introduction of heat pump water heaters (HPWHs). The addition of this energy-efficient technology to the market increases direct competition with solar water heaters (SWHs) for available energy savings. It is therefore essential to understand which segment of the market is best suited for HPWHs and focus the development of innovative, low-cost SWHs in the market segment where the largest opportunities exist. To evaluate cost and performance tradeoffs between high performance hot water heating systems, annual energy simulations were run using the program, TRNSYS, and analysis was performed to compare the energy savings associated with HPWH and SWH technologies to conventional methods of water heating.

  6. Consumer impacts on dividends from solar water heating

    Energy Technology Data Exchange (ETDEWEB)

    Hill, F.; Levermore, G. [University of Manchester, Manchester (United Kingdom); Lynch, H. [Centre for Alternative Technology, Machynlleth, University of East London, London (United Kingdom)

    2011-01-15

    Common domestic solar water heating system usage patterns were investigated by a survey of 55 installations. These usage patterns were modelled by simulation based on the actual occupants' use of boiler or other auxiliary heating control strategies. These strategies were not optimal, as often assumed. The effectiveness of the technology was found to be highly sensitive to the time settings used for auxiliary water heating, and the 65% of solar householders using their boilers in the mornings were found to be forgoing 75% of their potential savings. Additionally, 92% of consumers were found to be small households, whose potential savings were only 23% of those of larger households, which use more hot water. Overall the majority (at least 60%) of the systems surveyed were found to be achieving no more than 6% of their potential savings. Incorporating consideration of Legionella issues, results indicate that if solar thermal technology is to deliver its potential to CO2 reduction targets: solar householders must avoid any use of their auxiliary water heating systems before the end of the main warmth of the day, grants for solar technology should be focused on households with higher hot water demands, and particularly on those that are dependent on electricity for water heating, health and safety requirements for hot water storage must be reviewed and, if possible, required temperatures should be set at a lower level, so that carbon savings from solar water heating may be optimized.

  7. Installation package for a sunspot cascade solar water heating system

    Science.gov (United States)

    1980-01-01

    Solar water heating systems installed at Tempe, Arizona and San Diego, California are described. The systems consist of the following: collector, collector-tank water loop, solar tank, conventional tank, and controls. General guidelines which may be utilized in development of detailed installation plans and specifications are provided along with instruction on operation, maintenance, and installation of solar hot water systems.

  8. Decontamination of drinking water by direct heating in solar panels.

    Science.gov (United States)

    Fjendbo Jørgensen, A J; Nøhr, K; Sørensen, H; Boisen, F

    1998-09-01

    A device was developed for direct heating of water by solar radiation in a flow-through system of copper pipes. An adjustable thermostat valve prevents water below the chosen temperature from being withdrawn. The results show that it is possible to eliminate coliform and thermotolerant coliform bacteria from naturally contaminated river water by heating to temperatures of 65 degrees C or above. Artificial additions of Salmonella typhimurium, Streptococcus faecalis and Escherichia coli to contaminated river water were also inactivated after heating to 65 degrees C and above. The total viable count could be reduced by a factor of 1000. The heat-resistant bacteria isolated from the Mlalakuva River (Tanzania) were spore-forming bacteria which exhibited greater heat resistance than commonly used test bacteria originating from countries with colder climates. To provide a good safety margin it is recommended that an outlet water temperature of 75 degrees C be used. At that temperature the daily production was about 501 of decontaminated water per m2 of solar panel, an amount that could be doubled by using a heat exchanger to recycle the heat.

  9. Heat transfer performance of Al2O3/water nanofluids in a mini channel heat sink.

    Science.gov (United States)

    Dominic, A; Sarangan, J; Suresh, S; Sai, Monica

    2014-03-01

    The high density heat removal in electronic packaging is a challenging task of modern days. Finding compact, energy efficient and cost effective methods of heat removal is being the interest of researchers. In the present work, mini channel with forced convective heat transfer in simultaneously developing regime is investigated as the heat transfer coefficient is inversely proportional to hydraulic diameter. Mini channel heat sink is made from the aluminium plate of 30 mm square with 8 mm thickness. It has 15 mini channel of 0.9 mm width, 1.3 mm height and 0.9 mm of pitch. DI water and water based 0.1% and 0.2% volume fractions of Al2O3/water nanofluids are used as coolant. The flow rates of the coolants are maintained in such a way that it is simultaneously developing. Reynolds number is varied from 400 to 1600 and heat input is varied from 40 W to 70 W. The results showed that heat transfer coefficient is more than the heat transfer coefficient of fully developed flow. Also the heat transfer is more for nanofluids compared to DI water.

  10. Water recovery using waste heat from coal fired power plants.

    Energy Technology Data Exchange (ETDEWEB)

    Webb, Stephen W.; Morrow, Charles W.; Altman, Susan Jeanne; Dwyer, Brian P.

    2011-01-01

    The potential to treat non-traditional water sources using power plant waste heat in conjunction with membrane distillation is assessed. Researchers and power plant designers continue to search for ways to use that waste heat from Rankine cycle power plants to recover water thereby reducing water net water consumption. Unfortunately, waste heat from a power plant is of poor quality. Membrane distillation (MD) systems may be a technology that can use the low temperature waste heat (<100 F) to treat water. By their nature, they operate at low temperature and usually low pressure. This study investigates the use of MD to recover water from typical power plants. It looks at recovery from three heat producing locations (boiler blow down, steam diverted from bleed streams, and the cooling water system) within a power plant, providing process sketches, heat and material balances and equipment sizing for recovery schemes using MD for each of these locations. It also provides insight into life cycle cost tradeoffs between power production and incremental capital costs.

  11. Computational Simulation of a Water-Cooled Heat Pump

    Science.gov (United States)

    Bozarth, Duane

    2008-01-01

    A Fortran-language computer program for simulating the operation of a water-cooled vapor-compression heat pump in any orientation with respect to gravity has been developed by modifying a prior general-purpose heat-pump design code used at Oak Ridge National Laboratory (ORNL).

  12. Corrosion protection of steel in ammonia/water heat pumps

    Science.gov (United States)

    Mansfeld, Florian B.; Sun, Zhaoli

    2003-10-14

    Corrosion of steel surfaces in a heat pump is inhibited by adding a rare earth metal salt to the heat pump's ammonia/water working fluid. In preferred embodiments, the rare earth metal salt includes cerium, and the steel surfaces are cerated to enhance the corrosion-inhibiting effects.

  13. Prototype implementation and experimental analysis of water heating using recovered waste heat of chimneys

    Directory of Open Access Journals (Sweden)

    Mahmoud Khaled

    2015-03-01

    Full Text Available This work discusses a waste heat recovery system (WHRS applied to chimneys for heating water in residential buildings. A prototype illustrating the suggested system is implemented and tested. Different waste heat scenarios by varying the quantity of burned firewood (heat input are experimented. The temperature at different parts of the WHRS and the gas flow rates of the exhaust pipes are measured. Measurements showed that the temperature of 95 L tank of water can be increased by 68 °C within one hour. Obtained results show that the convection and radiation exchanges at the bottom surface of the tank have a considerable impact on the total heat transfer rate of the water (as high as 70%.

  14. Heat capacity and thermal expansion of water and helium

    Science.gov (United States)

    Putintsev, N. M.; Putintsev, D. N.

    2017-04-01

    Original expressions for heat capacity CV and its components, vibrational and configurational components of thermal expansion coefficient were established. The values of CV, Cvib, Cconf, αvib and αconf for water and helium 4He were calculated.

  15. Inactivation of porcine epidemic diarrhea virus using heated water

    Directory of Open Access Journals (Sweden)

    Michele M. Zentkovich

    2016-12-01

    Full Text Available Porcine epidemic diarrhea virus (PEDV is a very contagious swine pathogen that spreads easily via the fecal-oral route, notably from contaminated fomites. The present study investigated heated water as a method for rapid thermal inactivation of PEDV. Cell-culture adapted PEDV was treated with water at varying temperatures and viral titers were measured at multiple time points post-treatment. Viable PEDV was not recovered after a ten second or longer treatment with water heated to ≥76 °C; however, PEDV nucleic acid was detected in all samples regardless of treatment. Hot water decontamination could be considered in settings where chemical disinfection is impractical.

  16. Subscale Water Based Phase Change Material Heat Exchanger Development

    Science.gov (United States)

    Sheth, Rubik; Hansen, Scott

    2016-01-01

    Supplemental heat rejection devices are required in many spacecraft as the radiators are not sized to meet the full heat rejection demand. One means of obtaining additional heat rejection is through the use of phase change material heat exchangers (PCM HX's). PCM HX's utilize phase change to store energy in unfavorable thermal environments (melting) and reject the energy in favorable environments (freezing). Traditionally, wax has been used as a PCM on spacecraft. However, water is an attractive alternative because it is capable of storing about 40% more energy per unit mass due to its higher latent heat of fusion. The significant problem in using water as a PCM is its expansion while freezing, leading to structural integrity concerns when housed in an enclosed heat exchanger volume. Significant investigation and development has taken place over the past five years to understand and overcome the problems associated with water PCM HX's. This paper reports on the final efforts by Johnson Space Center's Thermal Systems Branch to develop a water based PCM HX. The test article developed and reported on is a subscale version of the full-scale water-based PCM HX's constructed by Mezzo Technologies. The subscale unit was designed by applying prior research on freeze front propagation and previous full-scale water PCM HX development. Design modifications to the subscale unit included use of urethane bladder, decreased aspect ratio, perforated protection sheet, and use of additional mid-plates. Testing of the subscale unit was successful and 150 cycles were completed without fail.

  17. The effects of water on heat-styling damage.

    Science.gov (United States)

    Christian, Paul; Winsey, Nigel; Whatmough, Marie; Cornwell, Paul A

    2011-01-01

    Heated styling appliances, such as straightening irons, have grown in popularity in recent years, as have hair products such as heat-protection sprays. In this study we investigate whether the water in a heat-protection spray can affect the level of damage caused by heat styling. Tryptophan damage from heat styling was measured using fluorescence spectroscopy, and structural damage was investigated using light microscopy and single-fiber tensile testing. Hair samples were heat treated with straightening irons, following treatment with either a water-based, "wet," heat-protection spray or an ethanol-based, "dry," spray. Results showed that, as expected, tryptophan damage was reduced by repeated applications of both the "wet" and "dry" heat-protection sprays. However, no differences were seen between the "wet" versus the "dry" product. Light microscopy studies showed greater structural damage to hair treated with water and the "wet" spray. Tensile tests confirmed that there was greater damage to hair treated with the "wet" spray. Decreases in Young's modulus were greater in the presence of the "wet" spray. The results of this study suggest that the type of damage caused by heat treatments is different in wet versus dry hair. In dry hair, thermal treatments cause chemical damage and some structural damage. However, in wet hair, thermal treatments cause the same chemical damage, but considerably more structural damage, which causes significant changes in the physical properties of the hair. It is likely that the rapid evaporation of water from the hair is the main causal factor. Our experiments suggest that the effectiveness of commercial heat-protection sprays can be improved by the removal of water and by the use of volatile ingredients, such as ethanol, as base solvents.

  18. Experimental investigation on water quality standard of Yangtze River water source heat pump.

    Science.gov (United States)

    Qin, Zenghu; Tong, Mingwei; Kun, Lin

    2012-01-01

    Due to the surface water in the upper reaches of Yangtze River in China containing large amounts of silt and algae, high content of microorganisms and suspended solids, the water in Yangtze River cannot be used for cooling a heat pump directly. In this paper, the possibility of using Yangtze River, which goes through Chongqing, a city in southwest China, as a heat source-sink was investigated. Water temperature and quality of the Yangtze River in the Chongqing area were analyzed and the performance of water source heat pump units in different sediment concentrations, turbidity and algae material conditions were tested experimentally, and the water quality standards, in particular surface water conditions, in the Yangtze River region that adapt to energy-efficient heat pumps were also proposed. The experimental results show that the coefficient of performance heat pump falls by 3.73% to the greatest extent, and the fouling resistance of cooling water in the heat exchanger increases up to 25.6% in different water conditions. When the sediment concentration and the turbidity in the river water are no more than 100 g/m3 and 50 NTU respectively, the performance of the heat pump is better, which can be used as a suitable river water quality standard for river water source heat pumps.

  19. Investigation of the Performance of a Heat Pump Using Waste Water as a Heat Source

    Directory of Open Access Journals (Sweden)

    Ali Kahraman

    2009-08-01

    Full Text Available In this research, a water-water heat pump system using waste water as a heat source, a type that is not often used in Turkey and the World, was experimentally modeled. The experiments were performed under the conditions of simulated waste water temperature values of 20 °C, 30 °C and 40 °C. Inlet and outlet water temperatures of the evaporator and condenser, water flow rates in the evaporator and condenser circuits, pressures at the compressor inlet and outlet and power consumption of the system were measured. The heating coefficients of performance were calculated based on the measurements. It was found that the maximum temperature in the energy storage tank was about 50.6 °C. For the heat source temperatures of 20 °C, 30 °C and 40 °C, the heating coefficients of the performance of the system became 3.36, 3.43 and 3.69, respectively, 6 min. after the start time of the experiments and then they were decreased to 1.87, 1.83 and 1.77 with increasing water temperature in the condenser tank. The mean uncertainty value of the measurement parameters was found to be about ±2.47%. Finally, for the purpose of meeting hot water need as well as floor heating system requirements, it is seen that energy quality level of a waste low grade temperature heat source can be increased by using a heat pump system.

  20. Water and heat balances in Doñana wetlands

    Directory of Open Access Journals (Sweden)

    A. Ramos-Fuertes

    2016-10-01

    Full Text Available This paper presents the main results of the study of water balance and surface heat balance in the Doñana marshlands. The study was based on a broad base of hydrometeorological data taken at 10 minute intervals from 2006 to 2011 by a network of six measuring stations located in areas of vegetation-free marsh. This information is used to characterize, at different time scales, the thermal behavior of the marsh by analyzing its hydrometeorology centering on the surface heat fluxes. Thus, we have modeled and analyzed the heat flux between the water and flooded soil and the processes of heat transfer between the water surface and the atmosphere. Special attention has been paid to evaporation, on which the marsh draining process depends.

  1. Analysis of thermosyphon heat exchangers for use in solar domestic hot water heating systems

    Science.gov (United States)

    Dahl, Scott David

    1998-11-01

    A recent innovation in the solar industry is the use of thermosyphon heat exchangers. Determining the performance of these systems requires knowledge of how thermosyphon flow rate and heat exchanger performance vary with operating conditions. This study demonstrates that several thermosyphon heat exchanger designs operate in the laminar mixed convection regime. Empirical heat transfer and pressure drop correlations are obtained for three tube-in-shell heat exchangers (four, seven, and nine tube). Thermosyphon flow is on the shell side. Correlations are obtained with uniform heat flux on the tube walls and with a mixture of glycol and water circulating inside the tubes. Ranges of Reynolds, Prandtl, and Grashof numbers are 50 to 1800, 2.5 and 6.0, and 4×105 to 1×108, respectively. Nusselt number correlations are presented in a form that combines the contributions of forced and natural convection, Nu4Mixed=Nu4Forced+Nu4Natural. The Nusselt number is influenced by natural convection when the term Raq0.25/(Re0.5Pr0.33) is greater than unity. Pressure drop through these three designs is not significantly affected by mixed convection because most pressure drop losses are at the heat exchanger inlet and outlet. A comparison and discussion of the performance of several other heat exchanger designs (tube-in-shell and coil-in- shell designs) are presented. Generally, the coil-in- shell heat exchangers perform better than the tube-in- shell heat exchangers. Data from all heat exchanger designs is used to develop a new one-dimensional model for thermosyphon heat exchangers in solar water heating systems. The model requires two empirically determined relationships, pressure drop as a function of water mass flow rate and the overall heat transfer coefficient-area product (UA) as a function of Reynolds, Prandtl, and Grashof number. A testing protocol is presented that describes the procedure to obtain the data for the correlations. Two new TRNSYS component models are presented

  2. Field Performance of Heat Pump Water Heaters in the Northeast

    Energy Technology Data Exchange (ETDEWEB)

    Shapiro, Carl [Consortium for Advanced Residential Buildings, Norfolk, CT (United States); Puttagunta, Srikanth [Consortium for Advanced Residential Buildings, Norfolk, CT (United States)

    2016-02-05

    Heat pump water heaters (HPWHs) are finally entering the mainstream residential water heater market. Potential catalysts are increased consumer demand for higher energy efficiency electric water heating and a new Federal water heating standard that effectively mandates use of HPWHs for electric storage water heaters with nominal capacities greater than 55 gallons. When compared to electric resistance water heating, the energy and cost savings potential of HPWHs is tremendous. Converting all electric resistance water heaters to HPWHs could save American consumers 7.8 billion dollars annually ($182 per household) in water heating operating costs and cut annual residential source energy consumption for water heating by 0.70 quads. Steven Winter Associates, Inc. embarked on one of the first in situ studies of these newly released HPWH products through a partnership with two sponsoring electric utility companies, National Grid and NSTAR, and one sponsoring energy efficiency service program administrator, Cape Light Compact. Recent laboratory studies have measured performance of HPWHs under various operating conditions, but publically available field studies have not been as available. This evaluation attempts to provide publicly available field data on new HPWHs by monitoring the performance of three recently released products (General Electric GeoSpring(TM), A.O. Smith Voltex(R), and Stiebel Eltron Accelera(R) 300). Fourteen HPWHs were installed in Massachusetts and Rhode Island and monitored for over a year. Of the 14 units, ten were General Electric models (50 gallon units), two were Stiebel Eltron models (80 gallon units), and two were A.O. Smith models (one 60-gallon and one 80-gallon unit).

  3. Field Performance of Heat Pump Water Heaters in the Northeast

    Energy Technology Data Exchange (ETDEWEB)

    Shapiro, C.; Puttagunta, S.

    2013-08-01

    Heat pump water heaters (HPWHs) are finally entering the mainstream residential water heater market. Potential catalysts are increased consumer demand for higher energy efficiency electric water heating and a new Federal water heating standard that effectively mandates use of HPWHs for electric storage water heaters with nominal capacities greater than 55 gallons. When compared to electric resistance water heating, the energy and cost savings potential of HPWHs is tremendous. Converting all electric resistance water heaters to HPWHs could save American consumers 7.8 billion dollars annually ($182 per household) in water heating operating costs and cut annual residential source energy consumption for water heating by 0.70 quads. Steven Winter Associates, Inc. embarked on one of the first in situ studies of these newly released HPWH products through a partnership with two sponsoring electric utility companies, National Grid and NSTAR, and one sponsoring energy efficiency service program administrator, Cape Light Compact. Recent laboratory studies have measured performance of HPWHs under various operating conditions, but publicly available field studies have not been as available. This evaluation attempts to provide publicly available field data on new HPWHs by monitoring the performance of three recently released products (General Electric GeoSpring(tm), A.O. Smith Voltex(r), and Stiebel Eltron Accelera(r)300). Fourteen HPWHs were installed in Massachusetts and Rhode Island and monitored for over a year. Of the 14 units, ten were General Electric models (50 gallon units), two were Stiebel Eltron models (80 gallon units), and two were A.O. Smith models (one 60-gallon and one 80-gallon unit).

  4. A data acquisition system for water heating and cooling experiments

    Science.gov (United States)

    Perea Martins, J. E. M.

    2017-01-01

    This work presents a simple analogue waterproof temperature probe design and its electronic interfacing with a computer to compose a data acquisition system for water temperature measurement. It also demonstrates the system usage through an experiment to verify the water heating period with an electric heater and another to verify the Newton’s law of cooling

  5. Modeling of waste heat recovery by looped water-in-steel heat pipes

    Energy Technology Data Exchange (ETDEWEB)

    Akyurt, M.; Lamfon, N.J.; Najjar, Y.S.H.; Habeebullah, M.H.; Alp, T.Y. [King Abdulaziz Univ., Jeddah (Saudi Arabia). College of Engineering

    1995-08-01

    Modeling and simulation of a water-in-steel heat pipe heat recovery system is undertaken in this paper. The heat recovery system consists of a looped two-phase thermosyphon that receives heat from the stack of a gas turbine engine and delivers it to the generator of an NH{sub 3}-H{sub 2}O absorption chiller. Variations in the operating temperature as well as evaporator geometry are investigated, and the consequences on system effectiveness are studied. It is concluded that the model for the water-in-steel looped thermosyphon overcomes drawbacks of the water-in-copper thermosyphon, and that the steel system is simpler in design, lower in cost, and more competent in performance. (author)

  6. Development of a nonazeotropic heat pump for crew hygiene water heating

    Science.gov (United States)

    Walker, David H.; Deming, Glenn I.

    1991-01-01

    A Phase 2 SBIR Program funded by the NASA Marshall Space Flight Center to develop a Nonazeotropic Heat Pump is described. The heat pump system which was designed, fabricated, and tested in the Foster-Miller laboratory, is capable of providing crew hygiene water heating for future manned missions. The heat pump utilizes a nonazeotropic refrigerant mixture which, in this application, provides a significant Coefficient of Performance improvement over a single-constituent working fluid. In order to take full advantage of the refrigerant mixture, compact tube-in-tube heat exchangers were designed. A high efficiency scroll compressor with a proprietary lubrication system was developed to meet the requirements of operation in zero-gravity. The prototype heat pump system consumes less than 200W of power compared to the alternative of electric cartridge heaters which would require 2 to 5 kW.

  7. Protein packing defects "heat up" interfacial water.

    Science.gov (United States)

    Sierra, María Belén; Accordino, Sebastián R; Rodriguez-Fris, J Ariel; Morini, Marcela A; Appignanesi, Gustavo A; Fernández Stigliano, Ariel

    2013-06-01

    Ligands must displace water molecules from their corresponding protein surface binding site during association. Thus, protein binding sites are expected to be surrounded by non-tightly-bound, easily removable water molecules. In turn, the existence of packing defects at protein binding sites has been also established. At such structural motifs, named dehydrons, the protein backbone is exposed to the solvent since the intramolecular interactions are incompletely wrapped by non-polar groups. Hence, dehydrons are sticky since they depend on additional intermolecular wrapping in order to properly protect the structure from water attack. Thus, a picture of protein binding is emerging wherein binding sites should be both dehydrons rich and surrounded by easily removable water. In this work we shall indeed confirm such a link between structure and dynamics by showing the existence of a firm correlation between the degree of underwrapping of the protein chain and the mobility of the corresponding hydration water molecules. In other words, we shall show that protein packing defects promote their local dehydration, thus producing a region of "hot" interfacial water which might be easily removed by a ligand upon association.

  8. Indirect heat integration across plants using hot water circles☆

    Institute of Scientific and Technical Information of China (English)

    Chenglin Chang; Yufei Wang; Xiao Feng

    2015-01-01

    Total site heat integration (TSHI) provides more opportunities for energy saving in industry clusters. Some design methods including direct integration using process streams and indirect integration using intermediate-fluid cir-cuits, i.e., steam, dowtherms and hot water, have been proposed during last few decades. Indirect heat integration is preferred when the heat sources and sinks are separated in independent plants with rather long distance. This improves energy efficiency by adaption of intermediate fluid circle which acts as a utility provider for plants in a symbiotic network. However, there are some significant factors ignored in conventional TSHI, i.e. the investment of pipeline, cost of pumping and heat loss. These factors simultaneously determine the possibility and perfor-mance of heat integration. This work presents a new methodology for indirect heat integration in low tempera-ture range using hot water circuit as intermediate-fluid medium. The new methodology enables the targeting of indirect heat integration across plants considering the factors mentioned earlier. An MINLP model with economic objective is established and solved. The optimization results give the mass flow rate of intermediate-fluid, diam-eter of pipeline, the temperature of the circuits and the matches of heat exchanger networks (HENS) automati-cally. Finally, the application of this proposed methodology is il ustrated with a case study.

  9. Water Based Phase Change Material Heat Exchanger Development

    Science.gov (United States)

    Hansen, Scott W.; Sheth, Ribik B.; Atwell, Matt; Cheek, Ann; Agarwal, Muskan; Hong, Steven; Patel, Aashini,; Nguyen, Lisa; Posada, Luciano

    2014-01-01

    In a cyclical heat load environment such as low Lunar orbit, a spacecraft’s radiators are not sized to reject the full heat load requirement. Traditionally, a supplemental heat rejection device (SHReD) such as an evaporator or sublimator is used to act as a “topper” to meet the additional heat rejection demands. Utilizing a Phase Change Material (PCM) heat exchanger (HX) as a SHReD provides an attractive alternative to evaporators and sublimators as PCM HXs do not use a consumable, thereby leading to reduced launch mass and volume requirements. Studies conducted in this paper investigate utilizing water’s high latent heat of formation as a PCM, as opposed to traditional waxes, and corresponding complications surrounding freezing water in an enclosed volume. Work highlighted in this study is primarily visual and includes understanding ice formation, freeze front propagation, and the solidification process of water/ice. Various test coupons were constructed of copper to emulate the interstitial pin configuration (to aid in conduction) of the proposed water PCM HX design. Construction of a prototypic HX was also completed in which a flexible bladder material and interstitial pin configurations were tested. Additionally, a microgravity flight was conducted where three copper test articles were frozen continuously during microgravity and 2-g periods and individual water droplets were frozen during microgravity.

  10. Heat pump using dual heat sources of air and water. Performance in cooling mode; Mizu kuki ryonetsugen heat pump no kenkyu. Reibo unten ni okeru seino

    Energy Technology Data Exchange (ETDEWEB)

    Ito, S.; Miura, N. [Kanagawa Institute of Technology, Kanagawa (Japan); Uchikawa, Y. [Kubota Corp., Osaka (Japan)

    1997-11-25

    When a heat pump is used for cooling purpose, it is possible to utilize different kinds of waste water as high-heat sources. However, these heat sources would have their temperatures vary with seasons and time in a day. Therefore, a discussion was given on performance of a heat pump when water and air heat sources are used for condensers during cooling operation independently, in series and in parallel, respectively. The air condenser shows an equivalent COP as compared with the water condenser when air temperature is lower by about 8 degC than water temperature. At the same heat source temperature, the COP for the water condenser indicated a value higher by about 0.6 than the case of the air condenser. A method to use condensers in parallel experiences little contribution from the air heat source, and performance of the heat pump decreases below the case of using the water heat source independently when the air heat source temperature becomes higher than that of the water heat source. In the case of series use in which a water condenser is installed in front and an air condenser in rear, its effect is exhibited when temperature in the air heat source is lower than that in the water heat source. Better performance was shown than in operating the water heat source independently. 2 refs., 9 figs.

  11. Development of an Air-Source Heat Pump Integrated with a Water Heating / Dehumidification Module

    Energy Technology Data Exchange (ETDEWEB)

    Rice, C Keith [ORNL; Uselton, Robert B. [Lennox Industries, Inc; Shen, Bo [ORNL; Baxter, Van D [ORNL; Shrestha, Som S [ORNL

    2014-01-01

    A residential-sized dual air-source integrated heat pump (AS-IHP) concept is under development in partnership between ORNL and a manufacturer. The concept design consists of a two-stage air-source heat pump (ASHP) coupled on the air distribution side with a separate novel water heating/dehumidification (WH/DH) module. The motivation for this unusual equipment combination is the forecast trend for home sensible loads to be reduced more than latent loads. Integration of water heating with a space dehumidification cycle addresses humidity control while performing double-duty. This approach can be applied to retrofit/upgrade applications as well as new construction. A WH/DH module capable of ~1.47 L/h water removal and ~2 kW water heating capacity was assembled by the manufacturer. A heat pump system model was used to guide the controls design; lab testing was conducted and used to calibrate the models. Performance maps were generated and used in a TRNSYS sub-hourly simulation to predict annual performance in a well-insulated house. Annual HVAC/WH energy savings of ~35% are predicted in cold and hot-humid U.S. climates compared to a minimum efficiency baseline.

  12. Numerical Prediction of Performance of Water Type Stirling Engine Considering Heat Exchange with Heat Sources

    Science.gov (United States)

    Yamaguchi, Yoshiyuki; Higuchi, Tetsuya

    Two different analytical models were developed on water type Stirling engine. One is the resonance model which qualitatively clarifies the relationship between performance and resonance tube length, and the other is the heat transfer model considering heat transfer between working gas and the tube walls of heating and cooling units. These analyses and experiments were carried out changing the resonance tube length variously, then it was confirmed that the resonance tube length which maximizes the water column amplitude of the power piston agrees well and the oscillations of water columns at that resonance tube length also agrees. In addition, a series of analysis using the heat transfer model was carried out with changing cross sectional area of the resonance tube, loss factors of the elbows, heat transfer area of heating and cooling unit, and pressure of working gas. By this numerical investigation, the effect on the resonance tube length and the work at the length in which these parameters maximize the amplitude of power piston water column was clarified.

  13. Analysis of Water Recovery Rate from the Heat Melt Compactor

    Science.gov (United States)

    Balasubramaniam, R.; Hegde, U.; Gokoglu, S.

    2013-01-01

    Human space missions generate trash with a substantial amount of plastic (20% or greater by mass). The trash also contains water trapped in food residue and paper products and other trash items. The Heat Melt Compactor (HMC) under development by NASA Ames Research Center (ARC) compresses the waste, dries it to recover water and melts the plastic to encapsulate the compressed trash. The resulting waste disk or puck represents an approximately ten-fold reduction in the volume of the initial trash loaded into the HMC. In the current design concept being pursued, the trash is compressed by a piston after it is loaded into the trash chamber. The piston face, the side walls of the waste processing chamber and the end surface in contact with the waste can be heated to evaporate the water and to melt the plastic. Water is recovered by the HMC in two phases. The first is a pre-process compaction without heat or with the heaters initially turned on but before the waste heats up. Tests have shown that during this step some liquid water may be expelled from the chamber. This water is believed to be free water (i.e., not bound with or absorbed in other waste constituents) that is present in the trash. This phase is herein termed Phase A of the water recovery process. During HMC operations, it is desired that liquid water recovery in Phase A be eliminated or minimized so that water-vapor processing equipment (e.g., condensers) downstream of the HMC are not fouled by liquid water and its constituents (i.e., suspended or dissolved matter) exiting the HMC. The primary water recovery process takes place next where the trash is further compacted while the heated surfaces reach their set temperatures for this step. This step will be referred to herein as Phase B of the water recovery process. During this step the waste chamber may be exposed to different selected pressures such as ambient, low pressure (e.g., 0.2 atm), or vacuum. The objective for this step is to remove both bound and

  14. Heat flux distribution on circulating fluidized bed boiler water wall

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    The future of circulating fluidized bed (CFB)combustion technology is in raising the steam parameters to supercritical levels.Understanding the heat flux distribution on the water wall is one of the most important issues in the design and operation of supercritical pressure CFB boilers.In the present paper,the finite element analysis (FEA) method is adopted to predict the heat transfer coefficient as well as the heat flux of the membrane wall and the results are validated by direct measurement of the temperature around the tube.Studies on the horizontal heat flux distribution were conducted in three CFB boilers with different furnace size,tube dimension and water temperature.The results are useful in supercritical pressure CFB boiler design.

  15. Overheating in Hot Water- and Steam-Heated Multifamily Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Dentz, J.; Varshney, K.; Henderson, H.

    2013-10-01

    Apartment temperature data have been collected from the archives of companies that provide energy management systems (EMS) to multifamily buildings in the Northeast U.S. The data have been analyzed from more than 100 apartments in eighteen buildings where EMS systems were already installed to quantify the degree of overheating. This research attempts to answer the question, 'What is the magnitude of apartment overheating in multifamily buildings with central hot water or steam heat?' This report provides valuable information to researchers, utility program managers and building owners interested in controlling heating energy waste and improving resident comfort. Apartment temperature data were analyzed for deviation from a 70 degrees F desired setpoint and for variation by heating system type, apartment floor level and ambient conditions. The data shows that overheating is significant in these multifamily buildings with both hot water and steam heating systems.

  16. THE HEAT AND FLUID FLOW ANALYSIS FOR WATER HEATER

    Directory of Open Access Journals (Sweden)

    Chien-Nan Lin

    2011-01-01

    Full Text Available In this paper, the heat transfer and fluid flow are studied for the water heater of RV cars, in which the hot water is heated by the combustion energy of liquefied petroleum gases. Three types of combustion tubes are performed in this investigation, which are circular tube, elliptic tube and elliptic tube with screwed wire inserted. The heat transfer performances of numerical simulation results are compared with those of the experimental works; they are in good trend agreement. The elliptic combustion tube performs better than the circular one, which indicates the average 7% energy saving for the elliptic combustion tube and 12% energy saving for the elliptic combustion tube with screwed wire under static heating.

  17. Solar hot water space heating system. Technical progress report

    Energy Technology Data Exchange (ETDEWEB)

    Van Dam, T

    1979-08-13

    A retrofit solar heating system was installed on Madison Hall at Jordan College, Cedar Springs, Michigan. The system provides heating and domestic water preheating for a campus dormitory. Freeze protection is provided by a draindown system. The building and solar system, construction progress, and design changes are described. Included in appendices are: condensate trap design, structural analysis, pictures of installation, operating instructions, maintenance instructions, and as-built drawings. (MHR)

  18. 24 CFR 200.950 - Building product standards and certification program for solar water heating system.

    Science.gov (United States)

    2010-04-01

    ... certification program for solar water heating system. 200.950 Section 200.950 Housing and Urban Development... solar water heating system. (a) Applicable standards. (1) All solar water heating systems shall be...) Document OG-300-93, Operating Guidelines and Minimum Standards for Certifying Solar Water Heating...

  19. Heat transfer studies in a spiral plate heat exchanger for water: palm oil two phase system

    Directory of Open Access Journals (Sweden)

    S. Ramachandran

    2008-09-01

    Full Text Available Experimental studies were conducted in a spiral plate heat exchanger with hot water as the service fluid and the two-phase system of water – palm oil in different mass fractions and flow rates as the cold process fluid. The two phase heat transfer coefficients were correlated with Reynolds numbers (Re in the form h = a Re m, adopting an approach available in literature for two phase fluid flow. The heat transfer coefficients were also related to the mass fraction of palm oil for identical Reynolds numbers. The two-phase multiplier (ratio of the heat transfer coefficient of the two phase fluid and that of the single phase fluid was correlated with the Lockhart Martinelli parameter in a polynomial form. This enables prediction of the two-phase coefficients using single-phase data. The predicted coefficients showed a spread of ± 10 % in the laminar range.

  20. High Efficiency R-744 Commercial Heat Pump Water Heaters

    Energy Technology Data Exchange (ETDEWEB)

    Elbel, Dr. Stefan W.; Petersen, Michael

    2013-04-25

    The project investigated the development and improvement process of a R744 (CO2) commercial heat pump water heater (HPWH) package of approximately 35 kW. The improvement process covered all main components of the system. More specific the heat exchangers (Internal heat exchanger, Evaporator, Gas cooler) as well as the expansion device and the compressor were investigated. In addition, a comparison to a commercially available baseline R134a unit of the same capacity and footprint was made in order to compare performance as well as package size reduction potential.

  1. Water heating solar system using collector with polycarbonate absorber surface

    Energy Technology Data Exchange (ETDEWEB)

    Souza, Luiz Guilherme Meira de; Sodre, Dilton; Cavalcanti, Eduardo Jose Cidade; Souza, Luiz Guilherme Vieira Meira de; Mendes, Jose Ubiragi de Lima [Universidade Federal do Rio Grande do Norte (UFRN), Natal, RN (Brazil)], e-mails: lguilherme@dem.ufrn.br, diltonsodre@ifba.edu.br, ubiragi@ct.ufrn.br

    2010-07-01

    It is presented s solar collector to be used in a heating water for bath system, whose main characteristics are low cost and easy fabrication and assembly processes. The collector absorber surface consists of a polycarbonate plate with an area of 1.5 m{sup 2}. The water inlet and outlet are made of PVC 50mm, and were coupled to a 6mm thick polycarbonate plate using fiberglass resin. A 200 liters thermal reservoir will be used. This reservoir is also alternative. The absorber heating system works under thermo-siphon regimen. Thermal parameters will be evaluated to prove the feasibility of the studied solar heating system to obtain bath water for a four people family. (author)

  2. Solar water heating system for a lunar base

    Science.gov (United States)

    Somers, Richard E.; Haynes, R. Daniel

    1992-01-01

    An investigation of the feasibility of using a solar water heater for a lunar base is described. During the investigation, computer codes were developed to model the lunar base configuration, lunar orbit, and heating systems. Numerous collector geometries, orientation variations, and system options were identified and analyzed. The results indicate that the recommended solar water heater could provide 88 percent of the design load and would not require changes in the overall lunar base design. The system would give a 'safe-haven' water heating capability and use only 7 percent to 10 percent as much electricity as an electric heating system. As a result, a fixed position photovoltaic array can be reduced by 21 sq m.

  3. Federal technology alert. Parabolic-trough solar water heating

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-04-01

    Parabolic-trough solar water heating is a well-proven renewable energy technology with considerable potential for application at Federal facilities. For the US, parabolic-trough water-heating systems are most cost effective in the Southwest where direct solar radiation is high. Jails, hospitals, barracks, and other facilities that consistently use large volumes of hot water are particularly good candidates, as are facilities with central plants for district heating. As with any renewable energy or energy efficiency technology requiring significant initial capital investment, the primary condition that will make a parabolic-trough system economically viable is if it is replacing expensive conventional water heating. In combination with absorption cooling systems, parabolic-trough collectors can also be used for air-conditioning. Industrial Solar Technology (IST) of Golden, Colorado, is the sole current manufacturer of parabolic-trough solar water heating systems. IST has an Indefinite Delivery/Indefinite Quantity (IDIQ) contract with the Federal Energy Management Program (FEMP) of the US Department of Energy (DOE) to finance and install parabolic-trough solar water heating on an Energy Savings Performance Contract (ESPC) basis for any Federal facility that requests it and for which it proves viable. For an ESPC project, the facility does not pay for design, capital equipment, or installation. Instead, it pays only for guaranteed energy savings. Preparing and implementing delivery or task orders against the IDIQ is much simpler than the standard procurement process. This Federal Technology Alert (FTA) of the New Technology Demonstration Program is one of a series of guides to renewable energy and new energy-efficient technologies.

  4. Heat pump applications and water heating by means of solar collectors. Waermepumpenanwendungen und Wasserwaermung mit Sonnenkollektoren

    Energy Technology Data Exchange (ETDEWEB)

    Szokody, G.

    1990-01-15

    About 25 to 30% of all newly constructed single-family houses in Switzerland are equipped with heat pump systems. This increasing attractivity is partly due to new techniques, e.g. microprocessor control, as well as to higher component efficiencies, a more efficient heat exchange technology, and to the compactness of systems. Active solar energy conversion, i.e. by means of solar collectors, is another technique which is predominantly applied for water heating in single-family buildings. Public investments in this field are scarce. (BWI).

  5. Analysis of a Residential Heating System Utilizing a Solar Assisted Water-to-Air Heat Pump.

    Science.gov (United States)

    1979-07-01

    heat pump heating system were analyzed. A realistic residence and solar assisted water-to-air heat pump system were modeled for this northern climate using the transient simulation computer code TRNSYS developed by the University of Wisconsin. The system was studied over a one month winter period, December, using actual hourly weather data. The system was analyzed for both the cloudiest and clearest December weather recorded in the last 30 years. The collector area and storage tank capacity were varied and the effects on system performance were

  6. Solar heating and hot water system installed at Listerhill, Alabama

    Science.gov (United States)

    1978-01-01

    The Solar system was installed into a new building and was designed to provide 79% of the estimated annual space heating load and 59% of the estimated annual potable hot water requirement. The collectors are flat plate, liquid manufactured by Reynolds Metals Company and cover a total area of 2344 square feet. The storage medium is water inhibited with NALCO 2755 and the container is an underground, unpressurized steel tank with a capacity of 5000 gallons. This report describes in considerable detail the solar heating facility and contains detailed drawings of the completed system.

  7. Solar heating and hot water system installed at Listerhill, Alabama

    Energy Technology Data Exchange (ETDEWEB)

    1978-12-01

    The solar system was installed into a new buildng and was designed to provide 79% of the estimated annual space heating load and 59% of the estimated annual potable hot water requirement. The collectors are flat plate, liquid manufactured by Reynolds Metals Company and cover a total area of 2344 square feet. The storage medium is water inhibited with NALCO 2755 and the container is an underground, unpressurized steel tank with a capacity of 5000 gallons. This final report describes in considerable detail the solar heating facility and contains detailed drawings of the completed system.

  8. Solar heating and hot water system installed at Listerhill, Alabama

    Energy Technology Data Exchange (ETDEWEB)

    1978-12-01

    The solar system was installed into a new buildng and was designed to provide 79% of the estimated annual space heating load and 59% of the estimated annual potable hot water requirement. The collectors are flat plate, liquid manufactured by Reynolds Metals Company and cover a total area of 2344 square feet. The storage medium is water inhibited with NALCO 2755 and the container is an underground, unpressurized steel tank with a capacity of 5000 gallons. This final report describes in considerable detail the solar heating facility and contains detailed drawings of the completed system.

  9. Role of Solar Water Heating in Multifamily Zero Energy Homes

    Energy Technology Data Exchange (ETDEWEB)

    Aldrich, Robb [Consortium for Advanced Residential Buildings, Norwalk, CT (United States); Williamson, James [Consortium for Advanced Residential Buildings, Norwalk, CT (United States)

    2016-04-08

    Solar domestic hot water (SDHW) systems have been installed on buildings for decades, but because of relatively high costs they have not achieved significant market penetration in most of the country. As more buildings move towards zero net energy consumption, however, many designers and developers are looking more closely at SDHW. In multifamily buildings especially, SDHW may be more practical for several reasons: 1) When designing for zero net energy consumption, solar water heating may be part of the lowest cost approach to meet water heating loads; 2) Because of better scale, SDHW systems in multifamily buildings cost significantly less per dwelling than in single-family homes; 3) Many low-load buildings are moving away from fossil fuels entirely. SDHW savings are substantially greater when displacing electric resistance water heating; and 4) In addition to federal tax incentives, some states have substantial financial incentives that dramatically reduce the costs (or increase the benefits) of SDHW systems in multifamily buildings. With support from the U.S. DOE Building America program, the Consortium for Advanced Residential Buildings (CARB) worked with a developer in western Massachusetts to evaluate a SDHW system on a 12-unit apartment building. Olive Street Development completed construction in spring of 2014, and CARB has been monitoring performance of the water heating systems since May 2014.

  10. Building America Case Study: Solar Water Heating in Multifamily Buildings

    Energy Technology Data Exchange (ETDEWEB)

    R. Aldrich and J. Williamson

    2016-05-01

    Solar domestic hot water (SDHW) systems have been installed on buildings for decades, but because of relatively high costs they have not achieved significant market penetration in most of the country. As more buildings move towards zero net energy consumption, however, many designers and developers are looking more closely at SDHW. In multifamily buildings especially, SDHW may be more practical for several reasons: (1) When designing for zero net energy consumption, solar water heating may be part of the lowest cost approach to meet water heating loads. (2.) Because of better scale, SDHW systems in multifamily buildings cost significantly less per dwelling than in single-family homes. (3) Many low-load buildings are moving away from fossil fuels entirely. SDHW savings are substantially greater when displacing electric resistance water heating. (4) In addition to federal tax incentives, some states have substantial financial incentives that dramatically reduce the costs (or increase the benefits) of SDHW systems in multifamily buildings. With support form the U.S. DOE Building America program, the Consortium for Advanced Residential Buildings (CARB) worked with a developer in western Massachusetts to evaluate a SDHW system on a 12-unit apartment building. Olive Street Development completed construction in spring of 2014, and CARB has been monitoring performance of the water heating systems since May 2014.

  11. Combined Space and Water Heating: Next Steps to Improved Performance

    Energy Technology Data Exchange (ETDEWEB)

    Schoenbauer, B. [NorthernSTAR Building America Partnership, Minneapolis, MN (United States); Bohac, D. [NorthernSTAR Building America Partnership, Minneapolis, MN (United States); Huelman, P. [NorthernSTAR Building America Partnership, Minneapolis, MN (United States)

    2016-07-13

    A combined space- and water-heating (combi) system uses a high-efficiency direct-vent burner that eliminates safety issues associated with natural draft appliances. Past research with these systems shows that using condensing water heaters or boilers with hydronic air handling units can provide both space and water heating with efficiencies of 90% or higher. Improved controls have the potential to reduce complexity and improve upon the measured performance. This project demonstrates that controls can significantly benefit these first-generation systems. Laboratory tests and daily load/performance models showed that the set point temperature reset control produced a 2.1%-4.3% (20-40 therms/year) savings for storage and hybrid water heater combi systems operated in moderate-load homes.

  12. Experimental Study of Thermoelectric Heat Pump Water Heater with Exhaust Heat Recovery from Kitchens

    Institute of Scientific and Technical Information of China (English)

    LIU Zhong-bing; ZHANG Ling; YANG Zhang; XU Ming; HAN Tian-he

    2009-01-01

    A new kind of thermoelectric heat pump water heater for kitchens exhaust heat recovery was pre-sented,and its performances were investigated under different operating voltages.The experiment results show that the coefficient of performance decreases and the temperature difference between the hot and cold sides be-comes larger with the increase of the operating voltage,but the heating time becomes short.The higher the temperature of water,the greater the temperature difference between the hot and cold sides,leading to a smaller eoeffieient of performance.Under an exhaust temperature of 36℃,the coefficient of performance decreases from 1.66 tO 1.22 when the temperature of water increases from 28℃to 46℃with operating voltage 16 V.Performance tests illustrate that,compared with the conventional electrical water heaters,the new kind of ther-moelectric heat pump water heater is more coefficient.

  13. Design of serially connected ammonia-water hybrid absorption-compression heat pumps for district heating with the utilisation of a geothermal heat source

    DEFF Research Database (Denmark)

    Jensen, Jonas Kjær; Ommen, Torben Schmidt; Markussen, Wiebke Brix;

    2016-01-01

    District heating (DH) can reduce the primary energy consumption in urban areas with significant heat demands. The design of a serially connected ammonia-water hybrid absorption-compression heat pump system was investigated for operation in the Greater Copenhagen DH network in Denmark, in order...... to supply 7.2 MW heat at 85 °C utilizing a geothermal heat source at 73 °C. Both the heat source and heat sink experience a large temperature change over the heat transfer process, of which a significant part may be achieved by direct heat exchange. First a generic study with a simple representation...

  14. Isolation of Naegleria fowleri from artificially heated water

    Energy Technology Data Exchange (ETDEWEB)

    Fliermans, C.B. (E.I. du Pont de Nemours and Co., Aiken, SC); Tyndall, R.L.; Domingue, E.L.; Willaert, E.J.P.

    1979-01-01

    Water samples were collected from artificially heated and ambient temperature water and processed for the presence of Naegleria fowleri. Samples taken from thermally altered habitats were positive 43% of the time, whereas ambient temperature habitats were positive 2% of the time. The data suggests that thermally altered aquatic systems in the south-eastern United States may provide habitats conducive to the proliferation of N. fowleri.

  15. Isolation of pathogenic Naegleria from artificially heated waters

    Energy Technology Data Exchange (ETDEWEB)

    Tyndall, R L; Willaert, E; Stevens, A R; Coutant, C C

    1977-01-01

    Investigations were undertaken to determine whether heated waters facilitate the proliferation of free-living amoeba that cause primary amoebic meningoencephalitis. Water samples were taken close to the discharges of power plants situated on lakes or rivers in Florida and Texas and from cooling towers in Tennessee. The water temperatures ranged from 29 to 42/sup 0/C. Water samples were also taken from several lakes in Florida and Texas without associated power plants. The water temperatures of these ranged from 30/sup 0/ to 34/sup 0/C. Twenty-five-250-ml samples were filtered through membranes. Samples taken from the control lakes and cooling towers showed no growth of pathogenic amoeba, whereas growth was obtained from 2 of the 8 lakes and rivers in Florida and from 1 of the 7 man-made lakes in Texas that were artificially heated. The amoebae were identified as belonging to the genus Naegleria from their trophozoite and cyst structure, ability to grow at 45/sup 0/C, to transform into flagellates, and to produce primary amebic meningoencephalitis (PAME) in mice after intranasal instillation. Their identification as N. fowleri was confirmed by indirect immunofluorescent analysis with antiserum produced against N. fowleri. These findings indicate that artificial heating of waters may facilitate the growth of pathogenic free living amoeba.

  16. Embedded water-based surface heating part 2: experimental validation

    DEFF Research Database (Denmark)

    Karlsson, Henrik

    2010-01-01

    : hybrid 3D numerical model. Journal of Building Physics 33: 357-391). The thermal response of the system is tested in both long (16 h) and short (30 min) cycle experiments where the water flow alters between on and off. Temperature distribution, within the floor construction, and the heat exchange process...... are studied throughout the test cycles. The model underestimates the steady-state heat exchange from the pipe loop by 16% when boundary conditions and thermal properties according to the reference case are applied. Temperatures at the floor surface are assessed with good precision while temperatures......The transient operation of an embedded water-based floor heating system has been studied by means of a numerical simulation tool. Prior to this study, Caccavelli and Richard (Caccavelli D, Richard P (1994) Etude portant sur le dimensionnement d'un plancher chauffant a eau chaude en CIC. Rapport n...

  17. Role of Solar Water Heating in Multifamily Zero Energy Homes

    Energy Technology Data Exchange (ETDEWEB)

    Aldrich, Robb [Consortium for Advanced Residential Buildings (CARB), Norwalk, CT (United States); Williamson, James [Consortium for Advanced Residential Buildings (CARB), Norwalk, CT (United States)

    2016-04-01

    With support from the U.S. Department of Energy Building America Program, the Consortium for Advanced Residential Buildings (CARB) worked with a developer in western Massachusetts to evaluate a SDHW system on a 12-unit apartment building. Olive Street Development completed construction in the spring of 2014, and CARB has been monitoring the performance of the water-heating systems since May 2014.

  18. Investigating movement of heat and water generators at work underground

    Directory of Open Access Journals (Sweden)

    Zholudyev S.V.

    2016-02-01

    Full Text Available The problems of coal excavation and environement protection are priority for Ukraine. Underground coal gasification (UCG and underground coal incineration (UCI are combining excavation with simultaneous underground processing in entire technological process, capable to solve this problem. Using an intermediate heat carrier - ground water may optimisating of these processes.

  19. Comfortable, high-efficiency heat pump with desiccant-coated, water-sorbing heat exchangers

    Science.gov (United States)

    Tu, Y. D.; Wang, R. Z.; Ge, T. S.; Zheng, X.

    2017-01-01

    Comfortable, efficient, and affordable heating, ventilation, and air conditioning systems in buildings are highly desirable due to the demands of energy efficiency and environmental friendliness. Traditional vapor-compression air conditioners exhibit a lower coefficient of performance (COP) (typically 2.8-3.8) owing to the cooling-based dehumidification methods that handle both sensible and latent loads together. Temperature- and humidity-independent control or desiccant systems have been proposed to overcome these challenges; however, the COP of current desiccant systems is quite small and additional heat sources are usually needed. Here, we report on a desiccant-enhanced, direct expansion heat pump based on a water-sorbing heat exchanger with a desiccant coating that exhibits an ultrahigh COP value of more than 7 without sacrificing any comfort or compactness. The pump’s efficiency is doubled compared to that of pumps currently used in conventional room air conditioners, which is a revolutionary HVAC breakthrough. Our proposed water-sorbing heat exchanger can independently handle sensible and latent loads at the same time. The desiccants adsorb moisture almost isothermally and can be regenerated by condensation heat. This new approach opens up the possibility of achieving ultrahigh efficiency for a broad range of temperature- and humidity-control applications.

  20. Comfortable, high-efficiency heat pump with desiccant-coated, water-sorbing heat exchangers

    Science.gov (United States)

    Tu, Y. D.; Wang, R. Z.; Ge, T. S.; Zheng, X.

    2017-01-01

    Comfortable, efficient, and affordable heating, ventilation, and air conditioning systems in buildings are highly desirable due to the demands of energy efficiency and environmental friendliness. Traditional vapor-compression air conditioners exhibit a lower coefficient of performance (COP) (typically 2.8–3.8) owing to the cooling-based dehumidification methods that handle both sensible and latent loads together. Temperature- and humidity-independent control or desiccant systems have been proposed to overcome these challenges; however, the COP of current desiccant systems is quite small and additional heat sources are usually needed. Here, we report on a desiccant-enhanced, direct expansion heat pump based on a water-sorbing heat exchanger with a desiccant coating that exhibits an ultrahigh COP value of more than 7 without sacrificing any comfort or compactness. The pump’s efficiency is doubled compared to that of pumps currently used in conventional room air conditioners, which is a revolutionary HVAC breakthrough. Our proposed water-sorbing heat exchanger can independently handle sensible and latent loads at the same time. The desiccants adsorb moisture almost isothermally and can be regenerated by condensation heat. This new approach opens up the possibility of achieving ultrahigh efficiency for a broad range of temperature- and humidity-control applications. PMID:28079171

  1. Comfortable, high-efficiency heat pump with desiccant-coated, water-sorbing heat exchangers.

    Science.gov (United States)

    Tu, Y D; Wang, R Z; Ge, T S; Zheng, X

    2017-01-12

    Comfortable, efficient, and affordable heating, ventilation, and air conditioning systems in buildings are highly desirable due to the demands of energy efficiency and environmental friendliness. Traditional vapor-compression air conditioners exhibit a lower coefficient of performance (COP) (typically 2.8-3.8) owing to the cooling-based dehumidification methods that handle both sensible and latent loads together. Temperature- and humidity-independent control or desiccant systems have been proposed to overcome these challenges; however, the COP of current desiccant systems is quite small and additional heat sources are usually needed. Here, we report on a desiccant-enhanced, direct expansion heat pump based on a water-sorbing heat exchanger with a desiccant coating that exhibits an ultrahigh COP value of more than 7 without sacrificing any comfort or compactness. The pump's efficiency is doubled compared to that of pumps currently used in conventional room air conditioners, which is a revolutionary HVAC breakthrough. Our proposed water-sorbing heat exchanger can independently handle sensible and latent loads at the same time. The desiccants adsorb moisture almost isothermally and can be regenerated by condensation heat. This new approach opens up the possibility of achieving ultrahigh efficiency for a broad range of temperature- and humidity-control applications.

  2. Optimization of Boiler Heat Load in Water-Heating Boiler-House

    Directory of Open Access Journals (Sweden)

    B. A. Bayrashevsky

    2009-01-01

    Full Text Available An analytical method for optimization of water-heating boiler loads has been developed on the basis of approximated semi-empirical dependences pertaining to changes of boiler gross efficiency due to its load. A complex (∂tух/∂ξΔξ is determined on the basis of a systematic analysis (monitoring of experimental data and the Y. P. Pecker’s formula for calculation of balance losses q2. This complex makes it possible to set a corresponding correction to a standard value of the boiler gross efficiency due to contamination of heating surfaces.Software means for optimization of water-heating boilers has been developed and it is recommended to be applied under operational conditions.

  3. Influence of System Variables on the Heating Characteristics of Water during Continuous Flow Microwave Heating

    Directory of Open Access Journals (Sweden)

    Hosahalli S. Ramaswamy

    2011-01-01

    Full Text Available A domestic microwave oven (1000 W was modified to permit the continuous flow of liquids run through a helical coil centrally located inside the oven cavity. Heating characteristics were evaluated by measuring inlet and outlet temperatures of coil as a function of system variables. The influence of number of turns, coil diameter, tube diameter, pitch and initial temperature were evaluated at different flow rates. The average residence time of water was computed by dividing the coil volume by the volumetric flow rate. The influence of Dean number was evaluated. Results from this study showed that (1 higher number of turns resulted in lower heating rate, lower temperature fluctuations, higher exit temperature and longer time to achieve temperature equilibrium; (2 larger tube or coil diameter gave larger coil volume causing the heating rate to decrease; (3 faster flow rates resulted in lower exit temperatures, lower temperature fluctuation, higher Dean number and slightly higher heating rate; (4 higher initial temperatures resulted in higher exit temperatures; (5 higher Dean number resulted in more uniform heating and slightly higher heating rate. Overall, the coil volume was the more dominant factor affecting heating rate as compared with flow rate and Dean number.

  4. Transient pool boiling heat transfer due to increasing heat inputs in subcooled water at high pressures

    Energy Technology Data Exchange (ETDEWEB)

    Fukuda, K. [Kobe Univ. of Mercantile Marine (Japan); Shiotsu, M.; Sakurai, A. [Kyoto Univ. (Japan)

    1995-09-01

    Understanding of transient boiling phenomenon caused by increasing heat inputs in subcooled water at high pressures is necessary to predict correctly a severe accident due to a power burst in a water-cooled nuclear reactor. Transient maximum heat fluxes, q{sub max}, on a 1.2 mm diameter horizontal cylinder in a pool of saturated and subcooled water for exponential heat inputs, q{sub o}e{sup t/T}, with periods, {tau}, ranging from about 2 ms to 20 s at pressures from atmospheric up to 2063 kPa for water subcoolings from 0 to about 80 K were measured to obtain the extended data base to investigate the effect of high subcoolings on steady-state and transient maximum heat fluxes, q{sub max}. Two main mechanisms of q{sub max} exist depending on the exponential periods at low subcoolings. One is due to the time lag of the hydrodynamic instability which starts at steady-state maximum heat flux on fully developed nucleate boiling (FDNB), and the other is due to the heterogenous spontaneous nucleations (HSN) in flooded cavities which coexist with vapor bubbles growing up from active cavities. The shortest period corresponding to the maximum q{sub max} for long period range belonging to the former mechanism becomes longer and the q{sub max}mechanism for long period range shifts to that due the HSN on FDNB with the increase of subcooling and pressure. The longest period corresponding to the minimum q{sub max} for the short period range belonging to the latter mechanism becomes shorter with the increase in saturated pressure. On the contrary, the longest period becomes longer with the increase in subcooling at high pressures. Correlations for steady-state and transient maximum heat fluxes were presented for a wide range of pressure and subcooling.

  5. Continued Water-Based Phase Change Material Heat Exchanger Development

    Science.gov (United States)

    Hansen, Scott W.; Sheth, Rubik B.; Poynot, Joe; Giglio, Tony; Ungar, Gene K.

    2015-01-01

    In a cyclical heat load environment such as low Lunar orbit, a spacecraft's radiators are not sized to meet the full heat rejection demands. Traditionally, a supplemental heat rejection device (SHReD) such as an evaporator or sublimator is used to act as a "topper" to meet the additional heat rejection demands. Utilizing a Phase Change Material (PCM) heat exchanger (HX) as a SHReD provides an attractive alternative to evaporators and sublimators as PCM HX's do not use a consumable, thereby leading to reduced launch mass and volume requirements. In continued pursuit of water PCM HX development two full-scale, Orion sized water-based PCM HX's were constructed by Mezzo Technologies. These HX's were designed by applying prior research on freeze front propagation to a full-scale design. Design options considered included bladder restraint and clamping mechanisms, bladder manufacturing, tube patterns, fill/drain methods, manifold dimensions, weight optimization, and midplate designs. Two units, Units A and B, were constructed and differed only in their midplate design. Both units failed multiple times during testing. This report highlights learning outcomes from these tests and are applied to a final sub-scale PCM HX which is slated to be tested on the ISS in early 2017.

  6. Laboratory Performance Evaluation of Residential Integrated Heat Pump Water Heaters

    Energy Technology Data Exchange (ETDEWEB)

    Sparn, B.; Hudon, K.; Christensen, D.

    2014-06-01

    This paper explores the laboratory performance of five integrated Heat Pump Water Heaters (HPWHs) across a wide range of operating conditions representative of US climate regions. HPWHs are expected to provide significant energy savings in certain climate zones when compared to typical electric resistance water heaters. Results show that this technology is a viable option in most climates, but differences in control schemes and design features impact the performance of the units tested. Tests were conducted to map heat pump performance across the operating range and to determine the logic used to control the heat pump and the backup electric heaters. Other tests performed include two unique draw profile tests, reduced air flow performance tests and the standard DOE rating tests. The results from all these tests are presented here for all five units tested. The results of these tests will be used to improve the EnergyPlus heat pump water heater for use in BEopt(tm) whole-house building simulations.

  7. Laboratory Performance Evaluation of Residential Integrated Heat Pump Water Heaters

    Energy Technology Data Exchange (ETDEWEB)

    Sparn, B.; Hudon, K.; Christensen, D.

    2014-06-01

    This paper explores the laboratory performance of five integrated Heat Pump Water Heaters (HPWHs) across a wide range of operating conditions representative of U.S. climate regions. HPWHs are expected to provide significant energy savings in certain climate zones when compared to typical electric resistance water heaters. Results show that this technology is a viable option in most climates, but differences in control schemes and design features impact the performance of the units tested. Tests were conducted to map heat pump performance across the operating range and to determine the logic used to control the heat pump and the backup electric heaters. Other tests performed include two unique draw profile tests, reduced air flow performance tests and the standard DOE rating tests. The results from all these tests are presented here for all five units tested. The results of these tests will be used to improve the EnergyPlus heat pump water heater for use in BEopt™ whole-house building simulations.

  8. Comparison of three systems of solar water heating by thermosiphon

    Science.gov (United States)

    Hernández, E.; Guzmán, R. E.

    2016-02-01

    The main purpose of this project was to elaborate a comparison between three water heating systems; using two plane water heating solar collector and another using a vacuum tube heater, all of them are on top of the cafeteria's roof on building of the “Universidad Pontificia Bolivariana” in Bucaramanga, Colombia. Through testing was determined each type of water heating systems' performance, where the Stainless Steel tube collector reached a maximum efficiency of 71.58%, the Copper Tubing Collector a maximum value of 76.31% and for the Vacuum Tube Heater Collector a maximum efficiency of 72.33%. The collector with copper coil was the system more efficient. So, taking into account the Performance and Temperature Curves, along with the weather conditions at the time of the testing we determined that the most efficient Solar Heating System is the one using a Vacuum Tube Heater Collector. Reaching a maximum efficiency of 72.33% and a maximum temperature of 62.6°C.

  9. Energy Savings Potential for Pumping Water in District Heating Stations

    Directory of Open Access Journals (Sweden)

    Ioan Sarbu

    2015-05-01

    Full Text Available In district heating stations, the heat carrier is circulated between the energy source and consumers by a pumping system. Fluid handling systems, such as pumping systems, are responsible for a significant portion of the total electrical energy use. Significant opportunities exist to reduce pumping energy through smart design, retrofitting, and operating practices. Most existing systems requiring flow control make use of bypass lines, throttling valves or pump speed adjustments. The most efficient of these options is pump speed control. One of the issues in using variable-speed pumping systems, however, is the total efficiency of the electric motor/pump arrangement under a given operating condition. This paper provides a comprehensive discussion about pump control in heating stations and analyzes the energy efficiency of flow control methods. Specific attention is also given to the selection of motor types, sizing and pump duty cycle. A comparative energy analysis is performed on the hot water discharge adjustment using throttling control valves and variable-speed drives in a district heating station constructed in Romania. To correlate the pumped flow rate with the heat demand and to ensure the necessary pressure using minimum energy, an automatic system has been designed. The performances of these control methods are evaluated in two practical applications. The results show that approximately 20%–50% of total pumping energy could be saved by using the optimal control method with variable-speed pumps. Additionally, some modernization solutions to reduce the environmental impact of heating stations are described.

  10. Overheating in Hot Water- and Steam-Heated Multifamily Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Dentz, J. [ARIES Collaborative, New York, NY (United States); Varshney, K. [ARIES Collaborative, New York, NY (United States); Henderson, H. [ARIES Collaborative, New York, NY (United States)

    2013-10-01

    In this project, the ARIES Building America team collected apartment temperature data from the archives of companies that provide energy management systems (EMS) to multifamily buildings in the Northeast U.S. Data was analyzed from more than 100 apartments in eighteen buildings where EMS systems were already installed to quantify the degree of overheating in an effort to answer the question, "What is the magnitude of apartment overheating in multifamily buildings with central hot water or steam heat?" This report provides valuable information to researchers, utility program managers and building owners interested in controlling heating energy waste and improving resident comfort.

  11. Active space heating and hot water supply with solar energy

    Energy Technology Data Exchange (ETDEWEB)

    Karaki, S.; Loef, G. O.G.

    1981-04-01

    Technical and economic assessments are given of solar water heaters, both circulating, and of air-based and liquid-based solar space heating systems. Both new and retrofit systems are considered. The technical status of flat-plate and evacuated tube collectors and of thermal storage is also covered. Non-technical factors are also briefly discussed, including the participants in the use of solar heat, incentives and deterrents. Policy implications are considered as regards acceleration of solar use, goals for solar use, means for achieving goals, and interaction of governments, suppliers, and users. Government actions are recommended. (LEW)

  12. Evaluation of heat and water flow in porosity permeable horizons

    Science.gov (United States)

    Pasquale, Vincenzo; Verdoya, Massimo; Chiozzi, Paolo

    2010-05-01

    Several strategies have been developed to explore the circulation of geofluids, which can yield heat transport over large spatial scales. Groundwater flow from recharge areas, where precipitation seeps downwards beneath the ground surface and reaches the saturated zone, to discharge areas, where subsurface water is discharged to streams, lakes, ponds or swamps, forms an additional mechanism of heat transfer to pure conduction, which is generally assumed for the underground thermal regime. In this paper we discuss and apply two different analytical models of heat and water flow, both valid for steady-state thermal conditions and for uniform, isotropic, homogeneous, and saturated porous media. By combining conductive and groundwater advective heat transfer, a first model assumes heat and water flow in vertical direction and neglects thermal gradient along the horizontal. The thermal field is influenced only by the flow of water parallel to the thermal gradient, whereas perpendicular water flow if any has no effect. Because most layers are sloping and because surface topographic relief usually exists across the aquifer, usually isotherms are not horizontal. Hence, we applied a second model for heat and water flow, neither purely horizontal nor purely vertical. In the governing equation of heat conduction-advection we take account of the horizontal flow of heat and water. The flow rate is assumed to be constant and sufficient small that thermal equilibrium is maintained between the water and the rock matrix. Examples of application are given for a set of boreholes drilled for geothermal exploration. Hydrothermal parameters (vertical and horizontal components of the Darcy velocity and the Péclet number) are determined by matching temperature and thermal gradient versus depth data with the two models. Thermal information is completed by a set of thermal conductivity measurements carried out on core samples recovered during drillings. The analysed underground

  13. Water, heat and salt transport through the Strait of Otranto

    Science.gov (United States)

    Yari, Sadegh; Gačić, Miroslav; Kovačević, Vedrana; Cardin, Vanessa

    2010-05-01

    The water, heat and salt transports through the Strait of Otranto are estimated applying direct method to historical current and hydrographical data (from December 94 through November 95). A variational inverse method based on a variational principle and a finite element solver is used to reconstruct the current, temperature and salinity fields across the Strait section from sparse measurements. The mean annual inflow and outflow water transport rates are estimated as 0.901±0.039 Sv and -0.939±0.315 Sv, respectively, and the net transport for the period of study is equal to -0.032±0.208 Sv. Thus, on a yearly time interval, the inflow and the outflow are practically compensated. The heat and salt transports due to advection process are estimated for five monthly periods, namely December 1994, February, May, August and November 1995. Considering these five periods representative of the seasonal cycle during the year, their average values show that there is a net heat advection into the Adriatic Sea on a yearly basis. The estimated value of advected heat and the corresponding error are 2.408±0.490 TW, which is equivalent to a heat gain of 17.37±3.53 W m-2 for the whole basin. This value is compared to the heat loss of -36±152 (std) W m-2 through the air-sea interface calculated by means of bulk formulas over the Adriatic Sea. The two values are expected to be balance each other in order to close the heat budget of the basin. The possible reasons for this difference to occur are discussed. On a yearly basis, the salt transport is estimated as an input of salt equal to 0.05×106 Kg s-1. The average annual fresh water budget is estimated as -0.002 Sv, equivalent to the mass of fresh water of 2.00×106Kg s-1 or to the level of 0.45 m yr-1 for the entire Adriatic Sea. The import of salt that is less than the gain of fresh water is in agreement with the fact that the Adriatic Sea is a dilution basin.

  14. Demand Response Performance of GE Hybrid Heat Pump Water Heater

    Energy Technology Data Exchange (ETDEWEB)

    Widder, Sarah H.; Parker, Graham B.; Petersen, Joseph M.; Baechler, Michael C.

    2013-07-01

    This report describes a project to evaluate and document the DR performance of HPWH as compared to ERWH for two primary types of DR events: peak curtailments and balancing reserves. The experiments were conducted with GE second-generation “Brillion”-enabled GeoSpring hybrid water heaters in the PNNL Lab Homes, with one GE GeoSpring water heater operating in “Standard” electric resistance mode to represent the baseline and one GE GeoSpring water heater operating in “Heat Pump” mode to provide the comparison to heat pump-only demand response. It is expected that “Hybrid” DR performance, which would engage both the heat pump and electric elements, could be interpolated from these two experimental extremes. Signals were sent simultaneously to the two water heaters in the side-by-side PNNL Lab Homes under highly controlled, simulated occupancy conditions. This report presents the results of the evaluation, which documents the demand-response capability of the GE GeoSpring HPWH for peak load reduction and regulation services. The sections describe the experimental protocol and test apparatus used to collect data, present the baselining procedure, discuss the results of the simulated DR events for the HPWH and ERWH, and synthesize key conclusions based on the collected data.

  15. Performance comparison for oil-water heat transfer of circumferential overlap trisection helical baffle heat exchanger

    Institute of Scientific and Technical Information of China (English)

    王伟晗; 程道来; 刘涛; 刘颖昊

    2016-01-01

    The performance tests were conducted on oil–water heat transfer in circumferential overlap trisection helical baffle heat exchangers with incline angles of 12°, 16°, 20°, 24° and 28°, and compared with a segmental baffle heat exchanger. The results show that the shell side heat transfer coefficientho and pressure dropΔpo both increase while the comprehensive indexho/Δpo decreases with the increase of the mass flow rate of all schemes. And the shell side heat transfer coefficient, pressure drop and the comprehensive indexho/Δpo decrease with the increase of the baffle incline angle at a certain mass flow rate. The average values of shell side heat transfer coefficient and the comprehensive indexho/Δpo of the 12° helical baffled scheme are above 50% higher than those of the segmental one correspondingly, while the pressure drop value is very close and the ratios of the average values are about 1.664 and 1.596, respectively. The shell-side Nusselt numberNuo and the comprehensive index Nuo·Euzo−1 increase with the increase of Reynolds number of the shell side axial in all schemes, and the results also demonstrate that the small incline angled helical scheme has better comprehensive performance.

  16. Hot water preparation using only a heat-pump; Warmwasserbereitung immer mit Waermepumpe

    Energy Technology Data Exchange (ETDEWEB)

    Mayer, H.; Gabathuler, H. R. [Gabathuler AG, beratende Ingenieure, Diessenhofen (Switzerland); Baumgartner, T. [Th. Baumgartner und Partner AG, Duebendorf (Switzerland)

    2007-07-01

    This article discusses the use of heat-pumps to heat up domestic hot water. The authors note that previously, heat-pumps were used to provide only space heating and domestic hot water was heated up using separate electrical heating elements. The results of a research and development project that defined standard configurations for small heat-pump installations that also provide hot water are discussed. An existing installation with two heat-pumps with ground-loop heat probes and a hot water store was used for tests. Measurements made and the results obtained are presented and discussed. Six configuration variants are described and their operation examined in detail. It is concluded that heat pumps may always be used for hot water preparation despite hygiene regulations demanding hot water temperatures up to 60 {sup o}C to prevent legionella growth.

  17. Solar Water Heating with Low-Cost Plastic Systems

    Energy Technology Data Exchange (ETDEWEB)

    None

    2012-01-01

    Federal buildings consumed over 392,000 billion Btu of site delivered energy for buildings during FY 2007 at a total cost of $6.5 billion. Earlier data indicate that about 10% of this is used to heat water.[2] Targeting energy consumption in Federal buildings, the Energy Independence and Security Act of 2007 (EISA) requires new Federal buildings and major renovations to meet 30% of their hot water demand with solar energy, provided it is cost-effective over the life of the system. In October 2009, President Obama expanded the energy reduction and performance requirements of EISA and its subsequent regulations with his Executive Order 13514.

  18. Solar water heating for aquaculture : optimizing design for sustainability

    Energy Technology Data Exchange (ETDEWEB)

    McDonald, M.; Thwaites, J. [Taylor Munro Energy Systems Inc., Delta, BC (Canada)

    2003-08-01

    This paper presents the results of a solar water heating project at Redfish Ranch, the first Tilapia tropical fish farm in British Columbia. The fish are raised in land-based tanks, eliminating the risk of contamination of local ecosystems. As a tropical species, they requires warm water. Natural gas or propane boilers are typically used to maintain tank temperatures at 26 to 28 degrees C. Redfish Ranch uses solar energy to add heat to the fish tanks, thereby reducing fossil-fuel combustion and greenhouse gas emissions. This unique building-integrated solar system is improving the environmental status of of this progressive industrial operation by offsetting fossil-fuel consumption. The system was relatively low cost, although substantial changes had to be made to the roof of the main building. The building-integrated design of the solar water heating system has reduced operating costs, generated local employment, and shows promise of future activity. As such, it satisfies the main criteria for sustainability. 7 refs.

  19. Municipal water-based heat pump heating and/or cooling systems: Findings and recommendations. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Bloomquist, R.G. [Washington, State Univ., Pullman, WA (United States); Wegman, S. [South Dakota Utilities Commission (United States)

    1998-04-01

    The purpose of the present work was to determine if existing heat pump systems based on municipal water systems meet existing water quality standards, to analyze water that has passed through a heat pump or heat exchanger to determine if corrosion products can be detected, to determine residual chlorine levels in municipal waters on the inlet as well as the outlet side of such installations, to analyses for bacterial contaminants and/or regrowth due to the presence of a heat pump or heat exchanger, to develop and suggest criteria for system design and construction, to provide recommendations and specifications for material and fluid selection, and to develop model rules and regulations for the installation, operation, and monitoring of new and existing systems. In addition, the Washington State University (WSU) has evaluated availability of computer models that would allow for water system mapping, water quality modeling and system operation.

  20. Analysis of IECC2003 Chiller Heat Recovery for Service Water Heating Requirement for New York State

    Energy Technology Data Exchange (ETDEWEB)

    Winiarski, David W.

    2004-08-15

    The state of New York asked the U.S. Department of Energy to evaluate the cost-effectiveness of the requirement for Heat Recovery for Service Water Heating that exists in the 2003 International Energy Conservation Code to determine whether this requirement should be adopted into the New York State Energy Code. A typical hotel application that would trigger this requirement was examined using whole building simulation software to generate baseline annual chiller and service hot water loads, and a spreadsheet was used to examine the energy savings potential for heat recovery using hourly load files from the simulation. An example application meeting the code requirement was developed, and the energy savings, energy cost savings, and first costs for the heat recovery installation were developed. The calculated payback for this application was 6.3 years using 2002 New York state average energy costs. This payback met the minimum requirements for cost effectiveness established for the state of New York for updating the commercial energy conservation code.

  1. Design of a Solar Water Heating System for Kuti Hall, University of ...

    African Journals Online (AJOL)

    Design of a Solar Water Heating System for Kuti Hall, University of Ibadan, Ibadan. ... an energy audit to determine daily heating load and energy eliminated by Solar ... of solar collector and Cold water temperature calculated from weather data ...

  2. Preliminary Analysis on Heat Removal Capacity of Passive Air-Water Combined Cooling Heat Exchanger Using MARS

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Seung-Sin; Jeon, Seong-Su; Hong, Soon-Joon [FNC Tech, Yongin (Korea, Republic of); Bae, Sung-Won; Kwon, Tae-Soon [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2015-10-15

    Current design requirement for working time of PAFS heat exchanger is about 8 hours. Thus, it is not satisfied with the required cooling capability for the long term SBO(Station Black-Out) situation that is required to over 72 hours cooling. Therefore PAFS is needed to change of design for 72 hours cooling. In order to acquirement of long terms cooling using PAFS, heat exchanger tube has to be submerged in water tank for long time. However, water in the tank is evaporated by transferred heat from heat exchanger tubes, so water level is gradually lowered as time goes on. The heat removal capacity of air cooling heat exchanger is core parameter that is used for decision of applicability on passive air-water combined cooling system using PAFS in long term cooling. In this study, the development of MARS input model and plant accident analysis are performed for the prediction of the heat removal capacity of air cooling heat exchanger. From analysis result, it is known that inflow air velocity is the decisive factor of the heat removal capacity and predicted air velocity is lower than required air velocity. But present heat transfer model and predicted air velocity have uncertainty. So, if changed design of PAFS that has over 4.6 kW heat removal capacity in each tube, this type heat exchanger can be applied to long term cooling of the nuclear power plant.

  3. Heat Pump Water Heaters and American Homes: A Good Fit?

    Energy Technology Data Exchange (ETDEWEB)

    Franco, Victor; Lekov, Alex; Meyers, Steve; Letschert, Virginie

    2010-05-14

    Heat pump water heaters (HPWHs) are over twice as energy-efficient as conventional electric resistance water heaters, with the potential to save substantial amounts of electricity. Drawing on analysis conducted for the U.S. Department of Energy's recently-concluded rulemaking on amended standards for water heaters, this paper evaluates key issues that will determine how well, and to what extent, this technology will fit in American homes. The key issues include: 1) equipment cost of HPWHs; 2) cooling of the indoor environment by HPWHs; 3) size and air flow requirements of HPWHs; 4) performance of HPWH under different climate conditions and varying hot water use patterns; and 5) operating cost savings under different electricity prices and hot water use. The paper presents the results of a life-cycle cost analysis of the adoption of HPWHs in a representative sample of American homes, as well as national impact analysis for different market share scenarios. Assuming equipment costs that would result from high production volume, the results show that HPWHs can be cost effective in all regions for most single family homes, especially when the water heater is not installed in a conditioned space. HPWHs are not cost effective for most manufactured home and multi-family installations, due to lower average hot water use and the water heater in the majority of cases being installed in conditioned space, where cooling of the indoor environment and size and air flow requirements of HPWHs increase installation costs.

  4. Heat production and heat loss responses to cold water immersion after 35 days horizontal bed rest.

    Science.gov (United States)

    Mekjavic, Igor B; Kounalakis, Stylianos N; Keramidas, Michail E; Biolo, Gianni; Narici, Marco; Eiken, Ola

    2012-05-01

    Bed rest is a terrestrial experimental analogue of unloading experienced during exposure to microgravity. Such unloading causes atrophy predominantly of the postural muscles, especially those of the lower limbs. We tested the hypothesis that 35 d horizontal bed rest alters thermoregulatory responses of subjects (N = 10) immersed in 15 degrees C water, particularly the heat produced by the shivering tremor of the skeletal muscles. Before and after bed rest we measured the thickness of the gastrocnemius medialis (GM), vastus lateralis (VL), tibialis anterior (TA), and biceps brachii (BB) muscles by ultrasonography. During the immersions, we monitored rectal and skin temperatures, heat flux, heart rate, and oxygen uptake. After bed rest, muscle thickness decreased significantly by 12.2 +/- 8.8% and 8.0 +/- 9.1% in the GM and VL, respectively. No changes were observed in the TA and BB muscles. The 35-d bed rest caused a significant reduction in aerobic power, as reflected in maximal oxygen uptake. There were no significant differences in any of the observed thermoregulatory responses between the pre- and post-bed rest immersions. Cardiovascular and muscular deconditioning had no effect on the heat production and heat loss responses. Due to the significant reduction in the mass of the muscles in the lower limbs, concomitant with no change in heat production, we conclude that leg muscles do not play a significant role in shivering thermogenesis.

  5. Investigation af a solar heating system for space heating and domestic hot water supply with a high degree of coverage

    DEFF Research Database (Denmark)

    Vejen, Niels Kristian

    1999-01-01

    A solar storage tank for space heating and domestic hot water supply was designed and testet in af laboratory test facility.......A solar storage tank for space heating and domestic hot water supply was designed and testet in af laboratory test facility....

  6. Combined Space and Water Heating: Next Steps to Improved Performance

    Energy Technology Data Exchange (ETDEWEB)

    Schoenbauer, B. [NorthernSTAR Building America Partnership, Minneapolis, MN (United States); Bohac, D. [NorthernSTAR Building America Partnership, Minneapolis, MN (United States); Huelman, P. [NorthernSTAR Building America Partnership, Minneapolis, MN (United States)

    2016-07-13

    A combined space- and water-heating (combi) system uses a high-efficiency direct-vent burner that eliminates safety issues associated with natural draft appliances. Past research with these systems shows that using condensing water heaters or boilers with hydronic air handling units can provide both space and water heating with efficiencies of 90% or higher. Improved controls have the potential to reduce complexity and improve upon the measured performance. This project demonstrates that controls can significantly benefit these first-generation systems. Laboratory tests and daily load/performance models showed that the set point temperature reset control produced a 2.1%–4.3% (20–40 therms/year) savings for storage and hybrid water heater combi systems operated in moderate-load homes. The full modulation control showed additional savings over set point control (in high-load homes almost doubling the savings: 4%–5% over the no-control case). At the time of installation the reset control can be implemented for $200–$400, which would provide paybacks of 6–25 years for low-load houses and 3–15 years for high-load houses. Full modulation implementation costs would be similar to the outdoor reset and would provide paybacks of 5-½–20 years for low-load houses and 2-½–10 years for high-load houses.

  7. Water and heat fluxes in desert soils: 2. Numerical simulations

    Science.gov (United States)

    Scanlon, Bridget R.; Milly, P. C. D.

    1994-03-01

    Transient one-dimensional fluxes of soil water (liquid and vapor) and heat in response to 1 year of atmospheric forcing were simulated numerically for a site in the Chihuahuan Desert of Texas. The model was initialized and evaluated using the monitoring data presented in a companion paper (Scanlon, this issue). Soil hydraulic and thermal properties were estimated a priori from a combination of laboratory measurements, models, and other published information. In the first simulation, the main drying curves were used to describe soil water retention, and hysteresis was ignored. Remarkable consistency was found between computed and measured water potentials and temperatures. Attenuation and phase shift of the seasonal cycle of water potentials below the shallow subsurface active zone (0.0- to 0.3-m depth) were similar to those of temperatures, suggesting that water potential fluctuations were driven primarily by temperature changes. Water fluxes in the upper 0.3 m of soil were dominated by downward and upward liquid fluxes that resulted from infiltration of rain and subsequent evaporation from the surface. Upward flux was vapor dominated only in the top several millimeters of the soil during periods of evaporation. Below a depth of 0.3 m, water fluxes varied slowly and were dominated by downward thermal vapor flux that decreased with depth, causing a net accumulation of water. In a second simulation, nonhysteretic water retention was instead described by the estimated main wetting curves; the resulting differences in fluxes were attributed to lower initial water contents (given fixed initial water potential) and unsaturated hydraulic conductivities that were lower than they were in the first simulation. Below a depth of 0.3 m, the thermal vapor fluxes dominated and were similar to those in the first simulation. Two other simulations were performed, differing from the first only in the prescription of different (wetter) initial water potentials. These three simulations

  8. Pressure Drop and Heat Transfer of Water Flowing Shell-Side of Multitube Heat Exchangers

    Science.gov (United States)

    Ohashi, Yukio; Hashizume, Kenichi

    Experimental studies on heat transfer augmentation in water-flowing shell sides of counter flow multitube exchangers are presented. Various kinds of augmented tube bundles have been examined to obtain the characteristics of pressure drop and heat transfer. Data for a smooth tube bundle were a little different from those for the tube side. The pressure drop in the shell side depended on Re-0.4 and deviated from the tube side pressure drop to within +30%, while the shell side heat transfer coefficient depended on Re0.8 but about 35%. larger than that of the tube side. Furthermore the augmented tube bundles have been evaluated and compared using 21 evaluation criteria. Enhanced tube bundles, low-finned tube bundles and those with twisted tapes inserted had especially good performances. The ratios of increase in heat transfer were larger than those in pressure drop. In case of low-finned tube bundles, there seem to exist an optimum fin-pitch and an optimum relation between the fin-pitch and the pitch of twisted tapes inserted.

  9. Melting Heat Transfer Characteristics of Latent Heat Microcapsule-Water Mixed Slurry Flowing in a Pipe with Constant Wall Heat Flux (Experimental Study)

    Science.gov (United States)

    Inaba, Hideo; Kim, Myoung-Jun; Horibe, Akihiko

    The present experiments have been performed for obtaining the melting heat transfer characteristics of micro-encapsulated solid-liquid phase change material and water mixed slurry flow in a circular tube heated with constant wall heat flux. The phase change material having a low melting point was selected for a domestic cooling system in the present study. The governing parameters were found to be latent heat material concentration,heat,flux,and the slurry velocity. The experimental results revealed that the mean heat transfer coefficient of latent microcapsule slurry was about l.3~l.8 times greater than that of the single phase of water. Moreover the effectiveness of heat transfer coefficient to friction factor had a maximum at latent heat material concentration of 25%.

  10. Technical and Economic Working Domains of Industrial Heat Pumps: Part 2 - Ammonia-Water Hybrid Absorption-Compression Heat Pumps

    DEFF Research Database (Denmark)

    Jensen, Jonas Kjær; Ommen, Torben Schmidt; Markussen, Wiebke Brix

    2014-01-01

    The ammonia-water hybrid absorption-compression heat pump (HACHP) is a relevant technology for industrial heat supply, especially for high sink temperatures and high temperature glides in the sink and source. This is due to the reduced vapour pressure and the non-isothermal phase change...... of the zeotropic mixture, ammonia-water. To evaluate to which extent these advantages can be translated into feasible heat pump solutions, the working domain of the HACHP is investigated based on technical and economic constraints. The HACHP working domain is compared to that of the best possible vapour...... compression heat pump with natural working fluids. This shows that the HACHP increases the temperature lifts and heat supply temperatures that are feasible to produce with a heat pump. The HACHP is shown to be capable of delivering heat supply temperatures as high as 140 XC and temperature lifts up to 60 K...

  11. Technical and economic working domains of industrial heat pumps: Part 2 - ammonia-water hybrid absorption-compression heat pumps

    DEFF Research Database (Denmark)

    Jensen, Jonas Kjær; Ommen, Torben Schmidt; Markussen, Wiebke Brix

    2015-01-01

    The ammonia-water hybrid absorption-compression heat pump (HACHP) has been proposed as a relevant technology for industrial heat supply, especially for high sink temperatures and high temperature glides in the sink and source. This is due to the reduced vapour pressure and the non-isothermal phase...... change of the zeotropic mixture, ammonia-water. To evaluate to which extent these advantages can be translated into feasible heat pump solutions, the working domain of the HACHP is investigated based on technical and economic constraints. The HACHP working domain is compared to that of the best available...... vapour compression heat pump with natural working fluids. This shows that the HACHP increases the temperature lifts and heat supply temperatures that are feasible to produce with a heat pump. The HACHP is shown to be capable of delivering heat supply temperatures as high as 150 °C and temperature lifts...

  12. Design and Evaluation of a Photovoltaic/Thermal-Assisted Heat Pump Water Heating System

    Directory of Open Access Journals (Sweden)

    Huan-Liang Tsai

    2014-05-01

    Full Text Available This paper presents the design, modelling and performance evaluation of a photovoltaic/thermal-assisted heat pump water heating (PVTA-HPWH system. The cooling effect of a refrigerant simultaneously enhances the PVT efficiency and effectively improves the coefficient of performance (COP of the HPWH system. The proposed model was built in the MATLAB/Simulink environment by considering the reciprocal energy exchange between a PVT evaporator and a HPWH system. In addition, the power consumption needs of the HPWH are provided by the PV electricity using a model-based control methodology. System performance is evaluated through a real field test. The results have demonstrated the power autarchy of the proposed PVTA-HPWH system with better PVT efficiency and COP. In addition, the good agreement between the model simulation and the experimental measurements demonstrate the proposed model with sufficient confidence.

  13. Preliminary design package for solar heating and hot water system

    Energy Technology Data Exchange (ETDEWEB)

    Levine, P.; Meyer, R.; White, James S.

    1977-01-01

    A collection of documents submitted by the Fern Engineering Company for the preliminary design review on the development of two prototype solar heating and hot water systems is presented. The information includes system certification, system functional description, system configuration, system specification, system performance and other documents pertaining to the progress and the design of the system. This system, which is intended for use in the normal single-family residence, consists of the following subsystems: collector, storage, control, transport, and Government-furnished Site Data Acquisition. One of the two prototype units will be installed in Lansing, Michigan, and the other in Tunkhannock, Pennsylvania.

  14. Artificial Neural Networks-Based Software for Measuring Heat Collection Rate and Heat Loss Coefficient of Water-in-Glass Evacuated Tube Solar Water Heaters.

    Science.gov (United States)

    Liu, Zhijian; Liu, Kejun; Li, Hao; Zhang, Xinyu; Jin, Guangya; Cheng, Kewei

    2015-01-01

    Measurements of heat collection rate and heat loss coefficient are crucial for the evaluation of in service water-in-glass evacuated tube solar water heaters. However, conventional measurement requires expensive detection devices and undergoes a series of complicated procedures. To simplify the measurement and reduce the cost, software based on artificial neural networks for measuring heat collection rate and heat loss coefficient of water-in-glass evacuated tube solar water heaters was developed. Using multilayer feed-forward neural networks with back-propagation algorithm, we developed and tested our program on the basis of 915 measured samples of water-in-glass evacuated tube solar water heaters. This artificial neural networks-based software program automatically obtained accurate heat collection rate and heat loss coefficient using simply "portable test instruments" acquired parameters, including tube length, number of tubes, tube center distance, heat water mass in tank, collector area, angle between tubes and ground and final temperature. Our results show that this software (on both personal computer and Android platforms) is efficient and convenient to predict the heat collection rate and heat loss coefficient due to it slow root mean square errors in prediction. The software now can be downloaded from http://t.cn/RLPKF08.

  15. Optimising Residential Water Heating System Performance to Minimise Water-Energy Penalties

    Directory of Open Access Journals (Sweden)

    Abel Silva Vieira

    2016-06-01

    Full Text Available The energy consumption associated with domestic hot water supply services correspond to a significant portion of the total energy consumption of the urban water cycle. The objective of this study is to analyse the performance of domestic water heaters in the three largest cities of Australia (i.e. Sydney, Melbourne and Brisbane. The performance of systems was investigated undertaking a multi-parametric analysis, in which energy efficiency indicators (i.e. energy intensity and power peaks were combined with level of service indicators (i.e. compliance rate with minimum temperature thresholds for end use points and hot water tanks. The operation of water heaters was modelled using the software EnergyPlus. Results demonstrate the need for a more holistic approach for the design and assessment of domestic water heaters taking into account not only the technology type to heat water, but also site specific aspects.

  16. Expert Meeting Report: Recommendations for Applying Water Heaters in Combination Space and Domestic Water Heating Systems

    Energy Technology Data Exchange (ETDEWEB)

    Rudd, A.; Ueno, K.; Bergey, D.; Osser, R.

    2012-07-01

    The topic of this meeting was 'Recommendations For Applying Water Heaters In Combination Space And Domestic Water Heating Systems.' Presentations and discussions centered on the design, performance, and maintenance of these combination systems, with the goal of developing foundational information toward the development of a Building America Measure Guideline on this topic. The meeting was held at the Westford Regency Hotel, in Westford, Massachusetts on 7/31/2011.

  17. Convective Heat and Mass Transfer in Water at Super—Critical Pressures under Heating or Cooling Conditions in Vertical Tubes

    Institute of Scientific and Technical Information of China (English)

    Pei-XueJiang; Ze-PeiRen; 等

    1995-01-01

    Forced and mixed convection heat and mass transfer are studied numerically for water containing metallic corrosion products in a heated or cooled vertical tube with variable thermophysical properties at super-citical pressures.the fouling mechanisms and fouling models are presented.The influence of variable properties at super-critical pressures on forced or mixed convection has been analyzed.The differences between heat and mass transfer under heating and cooling conditions are discussed.It is found that variable properties,especially buoyancy,greatly influence the fluid flow and heat mass fransfer.

  18. Thermal Interface Evaluation of Heat Transfer from a Pumped Loop to Titanium-Water Thermosyphons

    Science.gov (United States)

    Jaworske, Donald A.; Sanzi, James L.; Gibson, Marc A.; Sechkar, Edward A.

    2009-01-01

    Titanium-water thermosyphons are being considered for use in the heat rejection system for lunar outpost fission surface power. Key to their use is heat transfer between a closed loop heat source and the heat pipe evaporators. This work describes laboratory testing of several interfaces that were evaluated for their thermal performance characteristics, in the temperature range of 350 to 400 K, utilizing a water closed loop heat source and multiple thermosyphon evaporator geometries. A gas gap calorimeter was used to measure heat flow at steady state. Thermocouples in the closed loop heat source and on the evaporator were used to measure thermal conductance. The interfaces were in two generic categories, those immersed in the water closed loop heat source and those clamped to the water closed loop heat source with differing thermal conductive agents. In general, immersed evaporators showed better overall performance than their clamped counterparts. Selected clamped evaporator geometries offered promise.

  19. Development of seasonal heat storage based on stable supercooling of a sodium acetate water mixture

    DEFF Research Database (Denmark)

    Furbo, Simon; Fan, Jianhua; Andersen, Elsa

    2012-01-01

    A number of heat storage modules for seasonal heat storages based on stable supercooling of a sodium acetate water mixture have been tested by means of experiments in a heat storage test facility. The modules had different volumes and designs. Further, different methods were used to transfer heat....... • The reliability of the supercooling was elucidated for the heat storage modules for different operation conditions. • The reliability of a cooling method used to start solidification of the supercooled sodium acetate water mixture was elucidated. The method is making use of boiling CO2 in a small tank in good...... to and from the sodium acetate water mixture in the modules. By means of the experiments: • The heat exchange capacity rates to and from the sodium acetate water mixture in the heat storage modules were determined for different volume flow rates. • The heat content of the heat storage modules were determined...

  20. Integration of Space Heating and Hot Water Supply in Low Temperature District Heating

    DEFF Research Database (Denmark)

    Elmegaard, Brian; Ommen, Torben Schmidt; Markussen, Michael

    2014-01-01

    District heating makes it possible to provide heat for many consumers in an efficient manner. In particular, district heating based on combined heat and power production is highly efficient. One disadvantage of district heating is that there is a significant heat loss from the pipes to the surrou......District heating makes it possible to provide heat for many consumers in an efficient manner. In particular, district heating based on combined heat and power production is highly efficient. One disadvantage of district heating is that there is a significant heat loss from the pipes...... to the surrounding ground. In larger networks involving both transmission and distribution systems, the heat loss is most significant from the distribution network. An estimate is that about 80-90 % of the heat loss occurs in the distribution system. In addition, the heat loss is naturally highest from the forward...

  1. Heat Pump Water Heater Durabliltiy Testing - Phase II

    Energy Technology Data Exchange (ETDEWEB)

    Baxter, VAND.

    2004-05-29

    Ten heat pump water heaters (HPWH) were placed in an environmentally controlled test facility and run through a durability test program of approximately 7300 duty cycles (actual cycles accumulated ranged from 6640 to 8324 for the ten units). Five of the units were upgraded integral types (HPWH mounted on storage tank, no pump) from the same manufacturer as those tested in our first durability program in 2001 (Baxter and Linkous, 2002). The other five were ''add-on'' type units (HPWH with circulation pump plumbed to a separate storage tank) from another manufacturer. This durability test was designed to represent approximately 7-10 years of normal operation to meet the hot water needs of a residence. The integral units operated without incident apart from two control board failures. Both of these were caused by inadvertent exposure to very hot and humid (>135 F dry bulb and >120 F dew point) conditions that occurred due to a test loop failure. It is not likely that any residential water heater would be installed where such conditions were expected so these failures are not considered a long-term reliability concern. Two of the integral HPWHs featured a condensate management system (CMS) option that effectively eliminated any need for an evaporator condensate drain, but imposed significant efficiency penalties when operating in high humidity ambient conditions. The add-on units experienced no operational failures (breakdowns with loss of hot water production) during the course of the testing. However, their control systems exhibited some performance degradation under the high temperature, high humidity test conditions--HPWHs would shut off with tank water temperatures 15-20 F lower than when operating under moderate ambient conditions. One unit developed a refrigerant leak during the test program and lost about 50% of its charge resulting in reduced efficiency. Efficiency measurements on all the integral units and four of the add-on units showed

  2. Experimental Investigation of Thermal Performance of Miniature Heat Pipe Using SiO2-Water Nanofluids.

    Science.gov (United States)

    Niu, Yan-Fang; Zhao, Wei-Lin; Gong, Yu-Ying

    2015-04-01

    The four miniature heat pipes filled with DI water and SiO2-water nanofluids containing different volume concentrations (0.2%, 0.6% and 1.0%) are experimentally measured on the condition of air and water cooling. The wall temperature and the thermal resistance are investigated for three inclination angles. At the same of inlet heat water temperature in the heat system, it is observed that the total wall temperatures on the evaporator section are almost retaining constant by air cooling and the wall temperatures at the front end of the evaporator section are slightly reduced by water cooling. However, the wall temperatures at the condenser section using SiO2-water nanofluids are all higher than that for DI water on the two cooling conditions. As compared with the heat pipe using DI water, the decreasing of the thermal resistance in heat pipe using nanofluids is about 43.10%-74.46% by air cooling and 51.43%-72.22% by water cooling. These indicate that the utilization of SiO2-water nanofluids as working fluids enhances the performance of the miniature heat pipe. When the four miniature heat pipes are cut to examine at the end of the experiment, a thin coating on the surface of the screen mesh of the heat pipe using SiO2-water nanofluids is found. This may be one reason for reinforcing the heat transfer performance of the miniature heat pipe.

  3. Heat Transfer From Electrically Heated Nichrome Wires to Boiling Water at Different Pressures

    Directory of Open Access Journals (Sweden)

    Devi Dayal

    1968-01-01

    Full Text Available Boiling curves for nucleate and film boiling have been drawn for nichrome of three sizes in distilled and degasified water at saturation temperatures under five different sub-atmospheric vapour pressure. It has been observed that (i for the same Q/A (heat transfer, Delta Theta (excess of wire temperature over saturation point of water decreases with pressure in both nucleate and film boiling ranges, (ii Both Q/A max. and Delta Theta/SubC show a rapid decrease with pressure but these variations become more gradual at higher pressures, and (iii Q/A max. and Delta Theta/SubC increase with wire size at all pressures; increase in Delta Theta/SubC however, becomes less conspicuous at higher pressures approaching one atmosphere.

  4. Anomalous dependence of the heat capacity of supercooled water on pressure and temperature

    Directory of Open Access Journals (Sweden)

    I.A. Stepanov

    2014-01-01

    Full Text Available In some papers, dependences of the isobaric heat capacity of water versus pressure and temperature were obtained. It is shown that these dependences contradict both the dependence of heat capacity on temperature for supercooled water, and an important thermodynamic equation for the dependence of heat capacity on pressure. A possible explanation for this contradiction is proposed.

  5. Local convective heat transfer coefficient and friction factor of CuO/water nanofluid in a microchannel heat sink

    Science.gov (United States)

    Chabi, A. R.; Zarrinabadi, S.; Peyghambarzadeh, S. M.; Hashemabadi, S. H.; Salimi, M.

    2017-02-01

    Forced convective heat transfer in a microchannel heat sink (MCHS) using CuO/water nanofluids with 0.1 and 0.2 vol% as coolant was investigated. The experiments were focused on the heat transfer enhancement in the channel entrance region at Re Hydraulic performance of the MCHS was also estimated by measuring friction factor and pressure drop. Results showed that higher convective heat transfer coefficient was obtained at the microchannel entrance. Maximum enhancement of the average heat transfer coefficient compared with deionized water was about 40 % for 0.2 vol% nanofluid at Re = 1150. Enhancement of the convective heat transfer coefficient of nanofluid decreased with further increasing of Reynolds number.

  6. Heating of tap water in houses caused by district heating; Opwarmen leidingwater in woningen t.g.v. stadsverwarming

    Energy Technology Data Exchange (ETDEWEB)

    Van Wolferen, H. [TNO Bouw en Ondergrond, Apeldoorn (Netherlands)

    2007-07-15

    Practical research has been conducted on the option of heating tap water in houses due to district heating. Based on the results, guidelines are developed to prevent drinking water from being heated. The installation has been surveyed in 30 houses and in 24 of these houses temperatures have also been measured. Unwanted heating of drinking water, which occurred in 8 houses, can easily be solved by making minor adjustments to the installation with the aim of reducing heating. [mk]. [Dutch] Een praktijkonderzoek is uitgevoerd naar de eventuele opwarming van leidingwater in woningen t.g.v. stads- of blokverwarming. Op basis van de resultaten worden richtlijnen ontwikkeld om opwarmen van drinkwater te voorkomen. In 30 woningen is de installatie geschouwd en in 24 van deze woningen zijn tevens temperatuurmetingen uitgevoerd. In 8 woningen waarin ongewenste opwarming van drinkwater optreedt zijn eenvoudige aanpassingen aan de installatie verricht met als doel de opwarming te beperken.

  7. Solar heating and hot water system installed at Arlington Raquetball Club, Arlington, Virginia

    Science.gov (United States)

    1981-01-01

    A solar space and water heating system is described. The solar energy system consists of 2,520 sq. ft. of flat plate solar collectors and a 4,000 gallon solar storage tank. The transfer medium in the forced closed loop is a nontoxic antifreeze solution (50 percent water, 50 percent propylene glycol). The service hot water system consists of a preheat coil (60 ft. of 1 1/4 in copper tubing) located in the upper third of the solar storage tank and a recirculation loop between the preheat coil and the existing electric water heaters. The space heating system consists of two separate water to air heat exchangers located in the ducts of the existing space heating/cooling systems. The heating water is supplied from the solar storage tank. Extracts from site files, specification references for solar modifications to existing building heating and hot water systems, and installation, operation and maintenance instructions are included.

  8. Exergoeconomic optimization of an ammonia-water hybrid heat pump for heat supply in a spray drying facility

    DEFF Research Database (Denmark)

    Jensen, Jonas Kjær; Markussen, Wiebke Brix; Reinholdt, Lars

    2014-01-01

    Spray drying facilities are among the most energy intensive industrial processes. Using a heat pump to recover waste heat and replace gas combustion has the potential to attain both economic and emissions savings. In the case examined a drying gas of ambient air is heated to 200 XC. The inlet flow...... rate is 100,000 m3/h which yields a heat load of 6.1 MW. The exhaust air from the drying process is 80 XC. The implementation of an ammonia-water hybrid absorption-compression heat pump to partly cover the heat load is investigated. A thermodynamic analysis is applied to determine optimal circulation...... ratios for a number of ammonia mass fractions and heat pump loads. An exergoeconomic optimization is applied to minimize the lifetime cost of the system. Technological limitations are applied to constrain the solution to commercial components. The best possible implementation is identified in terms...

  9. Intelligent complete solution for heating and hot water; Intelligente Komplettloesung fuer Heizung und Warmwasser

    Energy Technology Data Exchange (ETDEWEB)

    Haegler, W.

    2002-07-01

    This article describes an integrated space-heating and hot-water heating system that is suitable for apartment buildings and housing estates. The concept, developed by a heating system planner in the Swiss Bernese Oberland, is described. The principles behind the system, which features centralised heat generation and decentralised hot-water storage, are discussed. The advantages offered by the system are compared with conventional solutions, whereby savings in investments and the use of standard components are commented on. The functioning of the decentralised hot-water boilers, which are heated up via the centralised heat distribution system at times when space-heating demands are low, is described. One of the many possibilities for the centralised generation of heat - a heat pump - is examined and the use of programmable controllers in the operation of the system is described.

  10. Solar technology assessment project. Volume 3: Active space heating and hot water supply with solar energy

    Science.gov (United States)

    Karaki, S.; Loef, G. O. G.

    1981-04-01

    Several types of solar water heaters are described and assessed. These include thermosiphon water heaters and pump circulation water heaters. Auxiliary water heating is briefly discussed, and new and retrofit systems are compared. Liquid-based space heating systems and solar air heaters are described and assessed, auxiliary space heating are discussed, and new and retrofit solar space heating systems are compared. The status of flat plate collectors, evacuated tube collectors, and thermal storage systems is examined. Systems improvements, reliability, durability and maintenance are discussed. The economic assessment of space and water heating systems includes a comparison of new systems costs with conventional fuels, and sales history and projections. The variety of participants in the solar industry and users of solar heat is discussed, and various incentives and barriers to solar heating are examined. Several policy implications are discussed, and specific government actions are recommended.

  11. Increase of COP for heat transformer in water purification systems. Part II - Without increasing heat source temperature

    Energy Technology Data Exchange (ETDEWEB)

    Romero, R.J. [Centro de Investigacion en Ingenieria y Ciencias Aplicadas, Universidad Autonoma del Estado de Morelos, Av. Universidad 1001, Col. Chamilpa, C.P. 62209 Cuernavaca, Morelos (Mexico)]. E-mail: rosenberg@uaem.mx; Siqueiros, J. [Centro de Investigacion en Ingenieria y Ciencias Aplicadas, Universidad Autonoma del Estado de Morelos, Av. Universidad 1001, Col. Chamilpa, C.P. 62209 Cuernavaca, Morelos (Mexico); Huicochea, A. [Posgrado en Ingenieria y Ciencias Aplicadas, Universidad Autonoma del Estado de Morelos, Av. Universidad 1001, Col. Chamilpa, C.P. 62209 Cuernavaca, Morelos (Mexico)

    2007-04-15

    The integration of a water purification system allows a heat transformer to increase the actual coefficient of performance, by the reduction of the amount of heat supplied by unit of heat. A new defined COP called COP{sub WP} is proposed for the present system, which considers the fraction of heat recycled. Simulation with proven software compares the performance of the modeling of an absorption heat transformer for water purification (AHTWP) operating with water/lithium bromide, as working fluid-absorbent pair. Plots of enthalpy-based coefficients of performance (COP{sub ET}) and water purification coefficient of performance (COP{sub WP}) are shown against absorber temperature for several thermodynamic operating conditions. The results showed that the proposed (AHTWP) system is capable of increasing the original value of COP{sub ET} up to 1.6 times its original value by recycling energy from a water purification system. The proposed COP{sub WP} allows increments for COP values from any experimental data for water purification or for any other distillation system integrated to a heat transformer, regardless of actual COP{sub A} value or working fluid-absorbent pair.

  12. Increase of COP for heat transformer in water purification systems. Pt. 2 - Without increasing heat source temperature

    Energy Technology Data Exchange (ETDEWEB)

    Romero, R.J.; Siqueiros, J. [Centro de Investigacion en Ingenieria y Ciencias Aplicadas, Universidad Autonoma del Estado de Morelos, Av. Universidad 1001, Col. Chamilpa, C.P. 62209 Cuernavaca, Morelos (Mexico); Huicochea, A. [Posgrado en Ingenieria y Ciencias Aplicadas, Universidad Autonoma del Estado de Morelos, Av. Universidad 1001, Col. Chamilpa, C.P. 62209 Cuernavaca, Morelos (Mexico)

    2007-04-15

    The integration of a water purification system allows a heat transformer to increase the actual coefficient of performance, by the reduction of the amount of heat supplied by unit of heat. A new defined COP called COP{sub WP} is proposed for the present system, which considers the fraction of heat recycled. Simulation with proven software compares the performance of the modeling of an absorption heat transformer for water purification (AHTWP) operating with water/lithium bromide, as working fluid-absorbent pair. Plots of enthalpy-based coefficients of performance (COP{sub ET}) and water purification coefficient of performance (COP{sub WP}) are shown against absorber temperature for several thermodynamic operating conditions. The results showed that the proposed (AHTWP) system is capable of increasing the original value of COP{sub ET} up to 1.6 times its original value by recycling energy from a water purification system. The proposed COP{sub WP} allows increments for COP values from any experimental data for water purification or for any other distillation system integrated to a heat transformer, regardless of actual COP{sub A} value or working fluid-absorbent pair. (author)

  13. Vapor compression CuCl heat pump integrated with a thermochemical water splitting cycle

    Energy Technology Data Exchange (ETDEWEB)

    Zamfirescu, C., E-mail: Calin.Zamfirescu@uoit.ca [Faculty of Engineering and Applied Science, University of Ontario Institute of Technology (UOIT), 2000 Simcoe Street North, Oshawa, ON, Canada L1H 74K (Canada); Naterer, G.F., E-mail: Greg.Naterer@uoit.ca [Faculty of Engineering and Applied Science, University of Ontario Institute of Technology (UOIT), 2000 Simcoe Street North, Oshawa, ON, Canada L1H 74K (Canada); Dincer, I., E-mail: Ibrahim.Dincer@uoit.ca [Faculty of Engineering and Applied Science, University of Ontario Institute of Technology (UOIT), 2000 Simcoe Street North, Oshawa, ON, Canada L1H 74K (Canada)

    2011-01-10

    In this paper, the feasibility of using cuprous chloride (CuCl) as a working fluid in a new high temperature heat pump with vapor compression is analyzed. The heat pump is integrated with a copper-chlorine (Cu-Cl) thermochemical water splitting cycle for internal heat recovery, temperature upgrades and hydrogen production. The minimum temperature of heat supply necessary for driving the water splitting cycle can be lowered because the heat pump increases the working fluid temperature from 755 K up to {approx}950 K, at a high COP of {approx}6.5. Based on measured data available in past literature, the authors have determined the T-s diagram of CuCl, which is then used for the thermodynamic modeling of the cycle. In the heat pump cycle, molten CuCl is flashed in a vacuum where the vapor quality reaches {approx}2.5%, and then it is boiled to produce saturated vapor. The vapor is then compressed in stages (with inter-cooling and heat recovery), and condensed in a direct contact heat exchanger to transfer heat at a higher temperature. The heat pump is then integrated with a copper-chlorine water splitting plant. The heat pump evaporator is connected thermally with the hydrogen production reactor of the water splitting plant, which performs an exothermic reaction that generates heat at 760 K. Additional source heat is obtained from heat recovery from the hot reaction products of the oxy-decomposer. The heat pump transfers heat at {approx}950 K to the oxy-decomposer to drive its endothermic chemical reaction. It is shown that the heat required at the heat pump source can be obtained completely from internal heat recovery within the plant. First and second law analyses and a parametric study are performed for the proposed system to study the influence of the compressor's isentropic efficiency and temperature levels on the heat pump's COP. Two new indicators are presented: one represents the heat recovery ratio (the ratio between the thermal energy obtained by

  14. Guided design of heating and cooling mains for lower water and energy consumption and increased efficiency

    CSIR Research Space (South Africa)

    Gololo, V

    2011-01-01

    Full Text Available in higher cooling water flowrate and low cooling water return temperature thus reducing cooling towers efficiency. This indicates the importance of the system structure, the possibility of mixing of heating or cooling water; recycling and reuse of heating...

  15. Drinking and water balance during exercise and heat acclimation

    Science.gov (United States)

    Greenleaf, J. E.; Brock, P. J.; Keil, L. C.; Morse, J. T.

    1983-01-01

    The interactions between fluid intake and balance, and plasma ion, osmotic, and endocrine responses during dehydration produced by exercise in cool and warm environments during acclimation are explored. Two groups of five male subjects performed 8 days of ergometer exercise in hot and thermoneutral conditions, respectively. The exercise trials lasted 2 hr each. Monitoring was carried out on the PV, osmotic, sodium, and endocrine concentrations, voluntary fluid intake, fluid balances, and fluid deficits. A negative correlation was observed between the plasma sodium and osmolality during acclimation. The presence of hypervolemia during acclimation is suggested as a cause of drinking, while the vasopressin concentration was not found to be a significant factor stimulating drinking. Finally, the predominant mechanism in fluid intake during exercise and heat exposure is concluded to be the renin-angiotensin II system in the presence of reductions in total body water and extracellular plasma volumes.

  16. High efficient ammonia heat pump system for industrial process water using the ISEC concept. Part 1

    DEFF Research Database (Denmark)

    Rothuizen, Erasmus Damgaard; Madsen, C.; Elmegaard, Brian

    2014-01-01

    The purpose of the Isolated System Energy Charging (ISEC) is to provide a high-efficient ammonia heat pump system for hot water production. The ISEC concept uses two storage tanks for the water, one discharged and one charged. The charged tank is used for the industrial process while the discharged...... to investigate the performance of the ISEC system. The ISEC concept approaches the efficiency of a number of heat pumps in series and the COP of the system may reach 6.8, which is up to 25 % higher than a conventional heat pump heating water in one step....... tank, is charging. Charging is done by circulating the water in the tank through the condenser several times and thereby gradually heats the water. This result in a lower condensing temperature than if the water was heated in one step. A dynamic model of the system, implemented in Dymola, is used...

  17. Measure Guideline. Combination Forced-Air Space and Tankless Domestic Hot Water Heating Systems

    Energy Technology Data Exchange (ETDEWEB)

    Rudd, Armin [Building Science Corporation Industry Team (BSC), Somerville, MA (United States)

    2012-08-01

    This document describes design and application guidance for combination space and tankless domestic hot water heating systems (combination systems) used in residential buildings, based on field evaluation, testing, and industry meetings conducted by Building Science Corporation. As residential building enclosure improvements continue to drive heating loads down, using the same water heating equipment for both space heating and domestic water heating becomes attractive from an initial cost and space-saving perspective. This topic is applicable to single- and multi-family residential buildings, both new and retrofitted.

  18. Measure Guideline: Combination Forced-Air Space and Tankless Domestic Hot Water Heating Systems

    Energy Technology Data Exchange (ETDEWEB)

    Rudd, A.

    2012-08-01

    This document describes design and application guidance for combination space and tankless domestic hot water heating systems (combination systems) used in residential buildings, based on field evaluation, testing, and industry meetings conducted by Building Science Corporation. As residential building enclosure improvements continue to drive heating loads down, using the same water heating equipment for both space heating and domestic water heating becomes attractive from an initial cost and space-saving perspective. This topic is applicable to single- and multi-family residential buildings, both new and retrofitted.

  19. Investigation of a low flow solar heating system for space heating and domestic hot water supply for Aidt Miljø A/S

    DEFF Research Database (Denmark)

    Vejen, Niels Kristian

    1997-01-01

    A low flow solar heating system for space heating and domestic hot water supply from Aidt Miljø A/Swas tested in a laboratory test facility.......A low flow solar heating system for space heating and domestic hot water supply from Aidt Miljø A/Swas tested in a laboratory test facility....

  20. Investigation of a solar heating system for space heating and domestic hot water supply for Sol&Træ A.m.b.a

    DEFF Research Database (Denmark)

    Vejen, Niels Kristian

    1999-01-01

    A solar heating system for space heating and domestic hot water supply from "Sol&Træ A.m.b.a." was tested in a laboratory test facility.......A solar heating system for space heating and domestic hot water supply from "Sol&Træ A.m.b.a." was tested in a laboratory test facility....

  1. Exergoeconomic optimization of an ammonia–water hybrid absorption–compression heat pump for heat supply in a spraydrying facility

    DEFF Research Database (Denmark)

    Jensen, Jonas Kjær; Markussen, Wiebke Brix; Reinholdt, Lars

    2015-01-01

    load of 6.1 MW. The exhaust air from the drying process is 80 C. The implementation of anammonia–water hybrid absorption–compression heat pump to partly cover the heat load is investigated. A thermodynamic analysis is applied to determine optimal circulation ratios for a number of ammonia mass...... fractions and heat pump loads. An exergo economic optimization is applied to minimize the lifetime cost of the system. Technological limitations are imposed to constrain the solution to commercial components. The best possible implementation is identified in terms of heat load, ammonia mass fraction...

  2. Steady and transient forced convection heat transfer for water flowing in small tubes with exponentially increasing heat inputs

    Science.gov (United States)

    Shibahara, M.; Fukuda, K.; Liu, Q. S.; Hata, K.

    2017-03-01

    Steady and transient heat transfer coefficients for water flowing in small tubes with exponentially increasing heat inputs were measured. Platinum tubes with inner diameters of 1.0 and 2.0 mm were used as test tubes, which were mounted vertically in the experimental water loop. In the experiment, the upward flow velocity ranged from 2 to 16 m/s, and the corresponding Reynolds numbers ranged from 4.77 × 103 to 9.16 × 104 at the inlet liquid temperatures ranged from 298 to 343 K. The heat generation rate exponentially increased with the function. The period of the heat generation rate ranged from 24 ms to 17.5 s. Experimental results indicate that steady heat transfer coefficients decreased with the increase in the inner diameter of the small tube. Moreover, the ratio of bulk viscosity to near-wall viscosity of water increased with the rise in surface temperature of the vertical tube. From the experimental data, correlations of steady-state heat transfer for inner diameters of 1.0 and 2.0 mm were obtained. The heat transfer coefficient increased with decreasing the period of the heat generation rate as the flow velocity decreased. Moreover, the Nusselt number under the transient condition was affected by the Fourier number and the Reynolds number.

  3. Natural convection heat exchangers for solar water heating systems. Technical progress report, September 15, 1996--November 14, 1996

    Energy Technology Data Exchange (ETDEWEB)

    Davidson, J.H.

    1998-06-01

    The goals of this project are: (1) to develop guidelines for the design and use of thermosyphon side-arm heat exchangers in solar domestic water heating systems, and (2) to establish appropriate modeling and testing criteria for evaluating the performance of systems using this type of heat exchanger. The tasks for the project are as follows: (1) Develop a model of the thermal performance of thermosyphon heat exchangers in solar water heating applications. A test protocol will be developed which minimizes the number of tests required to adequately account for mixed convection effects. The TRNSYS component model will be fully integrated in a system component model and will use data acquired with the specified test protocol. (2) Conduct a fundamental study to establish friction and heat transfer correlations for conditions and geometries typical of thermosyphon heat exchangers in solar systems. Data will be obtained as a function of a buoyancy parameter based on Grashof and Reynolds numbers. The experimental domain will encompass the ranges expected in solar water heating systems.

  4. Steady and transient forced convection heat transfer for water flowing in small tubes with exponentially increasing heat inputs

    Science.gov (United States)

    Shibahara, M.; Fukuda, K.; Liu, Q. S.; Hata, K.

    2016-06-01

    Steady and transient heat transfer coefficients for water flowing in small tubes with exponentially increasing heat inputs were measured. Platinum tubes with inner diameters of 1.0 and 2.0 mm were used as test tubes, which were mounted vertically in the experimental water loop. In the experiment, the upward flow velocity ranged from 2 to 16 m/s, and the corresponding Reynolds numbers ranged from 4.77 × 103 to 9.16 × 104 at the inlet liquid temperatures ranged from 298 to 343 K. The heat generation rate exponentially increased with the function. The period of the heat generation rate ranged from 24 ms to 17.5 s. Experimental results indicate that steady heat transfer coefficients decreased with the increase in the inner diameter of the small tube. Moreover, the ratio of bulk viscosity to near-wall viscosity of water increased with the rise in surface temperature of the vertical tube. From the experimental data, correlations of steady-state heat transfer for inner diameters of 1.0 and 2.0 mm were obtained. The heat transfer coefficient increased with decreasing the period of the heat generation rate as the flow velocity decreased. Moreover, the Nusselt number under the transient condition was affected by the Fourier number and the Reynolds number.

  5. Pool boiling of distilled water over tube bundle with variable heat flux

    Science.gov (United States)

    Swain, Abhilas; Mohanty, Rajiva Lochan; Das, Mihir Kumar

    2017-02-01

    The experimental investigation of saturated pool boiling heat transfer of distilled water over plain tube bundle, under uniform and varying heat flux condition along the height are presented in this article. Experiments are carried out under various heat flux configurations applied to rows of tube bundles and pitch distance to diameter ratios of 1.25, 1.6 and 1.95. The wall superheats and pool boiling heat transfer coefficients over individual rows are determined. The pool boiling heat transfer coefficients for variable heat flux and uniform heat flux conditions are compared. The results indicate that the bundle effect is found to exist for uniform as well as variable heat flux under all operating conditions in the present investigation. The variable heat flux resulted in range of wall superheat being highest for decreasing heat flux from bottom to top and lowest for increasing heat flux from bottom to top.

  6. Solar heating and hot water system installed at Shoney's Restaurant, North Little Rock, Arkansas

    Science.gov (United States)

    1980-01-01

    A solar heating system designed to supply a major portion of the space and water heating requirements for a restaurant is described. The restaurant has a floor space of approximately 4,650 square feet and requires approximate 1500 gallons of hot water daily. The solar energy system consists of 1,428 square feet of Chamberlain flat plate liquid collector subsystem, and a 1500 gallon storage subsystem circulating hot water producing 321 x 10 to the 6th power Btu/Yr (specified) building heating and hot water heating.

  7. Installation package for a domestic solar heating and hot water system

    Science.gov (United States)

    1978-01-01

    The installation of two prototype solar heating and hot water systems is described. The systems consists of the following subsystems: solar collector, storage, control, transport, and auxiliary energy.

  8. Flow Boiling Heat Transfer in Two-Phase Micro Channel Heat Sink at Low Water Mass Flux

    Science.gov (United States)

    Kuznetsov, Vladimir V.; Shamirzaev, Alisher S.

    2009-08-01

    Boiling heat transfer at water flow with low mass flux in heat sink which contained rectangular microchannels was studied. The stainless steel heat sink contained ten parallel microchannels with a size of 640 × 2050 μm in cross-section with typical wall roughness of 10-15 μm. The local flow boiling heat transfer coefficients were measured at mass velocity of 17 and 51 kg/m2s, heat flux on 30 to 150 kW/m2 and vapor quality of up to 0.8 at pressure in the channels closed to atmospheric one. It was observed that Kandlikar nucleate boiling correlation is in good agreement with the experimental data at mass flow velocity of 85 kg/m2s. At smaller mass flux the Kandlikar model and Zhang, Hibiki and Mishima model demonstrate incorrect trend of heat transfer coefficients variation with vapor quality.

  9. Compact water depth sensor with LPFG using the photoelastic effect and heat-shrinkable tube

    Science.gov (United States)

    Takama, Shinya; Kudomi, Takamasa; Ohashi, Masaharu; Miyoshi, Yuji

    2011-12-01

    We propose a compact water depth sensor with a long period fiber grating (LPFG) using a heat-shrinkable tube. The pressure property of the LPFG is investigated experimentally to confirm the feasibility of the water depth sensor. Moreover, the water depth in the 2m long water-filled pipe is successfully estimated by the proposed water sensors.

  10. Heat-resistant protein expression during germination of maize seeds under water stress.

    Science.gov (United States)

    Abreu, V M; Silva Neta, I C; Von Pinho, E V R; Naves, G M F; Guimarães, R M; Santos, H O; Von Pinho, R G

    2016-08-12

    Low water availability is one of the factors that limit agricultural crop development, and hence the development of genotypes with increased water stress tolerance is a challenge in plant breeding programs. Heat-resistant proteins have been widely studied, and are reported to participate in various developmental processes and to accumulate in response to stress. This study aimed to evaluate heat-resistant protein expression under water stress conditions during the germination of maize seed inbreed lines differing in their water stress tolerance. Maize seed lines 91 and 64 were soaked in 0, -0.3, -0.6, and -0.9 MPa water potential for 0, 6, 12, 18, and 24 h. Line 91 is considered more water stress-tolerant than line 64. The analysis of heat-resistant protein expression was made by gel electrophoresis and spectrophotometry. In general, higher expression of heat-resistant proteins was observed in seeds from line 64 subjected to shorter soaking periods and lower water potentials. However, in the water stress-tolerant line 91, a higher expression was observed in seeds that were subjected to -0.3 and -0.6 MPa water potentials. In the absence of water stress, heat-resistant protein expression was reduced with increasing soaking period. Thus, there was a difference in heat-resistant protein expression among the seed lines differing in water stress tolerance. Increased heat-resistant protein expression was observed in seeds from line 91 when subjected to water stress conditions for longer soaking periods.

  11. PARAMETERS OF WATER CIRCULATION NETWORK FOR A DISTRICT HEATING AND COOLING SYSTEM

    Institute of Scientific and Technical Information of China (English)

    2000-01-01

    In a district heating and cooling system, i.e. Beijing combined heating cooling and power (CHCP) system studied here, high temperature water generated by two cogeneration plants circulates through a network between the plants and heat substations. At heat substations, supply water of high temperature from the network drives absorption chillers for air-conditioning in summer and meets space heating demands in winter or domestic hot water demands by heat exchangers in the whole year. The parameters, i.e. supply/return water temperature in the network, has a great impact on primary energy consumption (PEC) of the absorption chillers, circulation pumps and domestic hot water (DHW), which is studied in this paper.

  12. Nano-Pervaporation Membrane with Heat Exchanger Generates Medical-Grade Water

    Science.gov (United States)

    Tsai, Chung-Yi; Alexander, Jerry

    2009-01-01

    A nanoporous membrane is used for the pervaporation process in which potable water is maintained, at atmospheric pressure, on the feed side of the membrane. The water enters the non-pervaporation (NPV) membrane device where it is separated into two streams -- retentate water and permeated water. The permeated pure water is removed by applying low vapor pressure on the permeate side to create water vapor before condensation. This permeated water vapor is subsequently condensed by coming in contact with the cool surface of a heat exchanger with heat being recovered through transfer to the feed water stream.

  13. European Regional Climate Zone Modeling of a Commercial Absorption Heat Pump Hot Water Heater

    Energy Technology Data Exchange (ETDEWEB)

    Sharma, Vishaldeep [ORNL; Shen, Bo [ORNL; Keinath, Chris [Stone Mountain Technologies, Inc., Johnson City; Garrabrant, Michael A. [Stone Mountain Technologies, Inc., Johnson City; Geoghegan, Patrick J [ORNL

    2017-01-01

    High efficiency gas-burning hot water heating takes advantage of a condensing heat exchanger to deliver improved combustion efficiency over a standard non-condensing configuration. The water heating is always lower than the gas heating value. In contrast, Gas Absorption Heat Pump (GAHP) hot water heating combines the efficiency of gas burning with the performance increase from a heat pump to offer significant gas energy savings. An ammonia-water system also has the advantage of zero Ozone Depletion Potential and low Global Warming Potential. In comparison with air source electric heat pumps, the absorption system can maintain higher coefficients of performance in colder climates. In this work, a GAHP commercial water heating system was compared to a condensing gas storage system for a range of locations and climate zones across Europe. The thermodynamic performance map of a single effect ammonia-water absorption system was used in a building energy modeling software that could also incorporate the changing ambient air temperature and water mains temperature for a specific location, as well as a full-service restaurant water draw pattern.

  14. Laboratory Evaluation of Gas-Fired Tankless and Storage Water Heater Approaches to Combination Water and Space Heating

    Energy Technology Data Exchange (ETDEWEB)

    Kingston, T. [Gas Technology Inst., Des Plaines, IL (United States); Scott, S. [Gas Technology Inst., Des Plaines, IL (United States)

    2013-03-01

    Homebuilders are exploring more cost-effective combined space and water heating systems (combo systems) with major water heater manufacturers that are offering pre-engineered forced air space heating combo systems. In this project, unlike standardized tests, laboratory tests were conducted that subjected condensing tankless and storage water heater based combo systems to realistic, coincidental space and domestic hot water loads and found that the tankless combo system maintained more stable DHW and space heating temperatures than the storage combo system, among other key findings.

  15. Performance of water source heat pump system using high-density polyethylene tube heat exchanger wound with square copper wire

    Directory of Open Access Journals (Sweden)

    Xin Wen Zhang

    2015-07-01

    Full Text Available Surface water source heat pump system is an energy-efficient heat pump system. Surface water heat exchanger is an important part of heat pump system that can affect the performance of the system. In order to enhance the performance of the system, the overall heat transfer coefficient (U value of the water exchanger using a 32A square copper coiled high-density polyethylene tube was researched. Comparative experiments were conducted between the performance of the coiled high-density polyethylene tube and the 32A smooth high-density polyethylene tube. At the same time, the coefficient of performance of the heat pump was investigated. According to the result, the U value of the coiled tube was 18% higher than that of the smooth tube in natural convection and 19% higher in forced convection. The coefficient of performance of the heat pump with the coiled tube is higher than that with the smooth tube. The economic evaluation of the coiled tube was also investigated.

  16. Experimental investigation of heat transfer and pressure drop characteristics of water and glycol-water mixture in multi-port serpentine microchannel slab heat exchangers

    Science.gov (United States)

    Khan, Md Mesbah-ul Ghani

    Microchannels have several advantages over traditional large tubes. Heat transfer using microchannels recently have attracted significant research and industrial design interests. Open literatures leave with question on the applicability of classical macroscale theory in microchannels. Better understanding of heat transfer in various microchannel geometries and building experimental database are continuously urged. The purpose of this study is to contribute the findings and data to this emerging area through carefully designed and well controlled experimental works. The commercially important glycol-water mixture heat transfer fluid and multiport slab serpentine heat exchangers are encountered in heating and cooling areas, e.g. in automotive, aircraft, and HVAC industries. For a given heat duty, the large diameter tubes experience turbulent flow whereas the narrow channels face laminar flow and often developing flow. Study of low Reynolds number developing glycol-water mixture laminar flow in serpentine microchannel heat exchanger with parallel multi-port slab is not available in the open literature. Current research therefore experimentally investigates glycol-water mixture and water in simultaneously developing laminar flows. Three multiport microchannel heat exchangers; straight and serpentine slabs, are used for each fluid. Friction factors of glycol-water mixture and water flows in straight slabs are higher than conventional fully developed laminar flow. If a comprehensive pressure balance is introduced, the results are well compared with conventional Poiseuille theory. Similar results are found in serpentine slab. The pressure drop for the straight core is the highest, manifolds are the intermediate, and serpentine is the least; which are beneficial for heat exchangers. The heat transfer results in serpentine slab for glycol-water mixture and water are higher and could not be compared with conventional fully developed and developing flow correlations. New

  17. Impact on Water Heater Performance of Heating Methods that Promote Tank Temperature Stratification

    Energy Technology Data Exchange (ETDEWEB)

    Gluesenkamp, Kyle R [ORNL; BushPE, John D [Electric Power Research Institute (EPRI)

    2016-01-01

    During heating of a water heater tank, the vertical temperature stratification of the water can be increased or decreased, depending on the method of heating. Methods that increase stratification during heating include (1) removing cold water from the tank bottom, heating it, and re-introducing it to the tank top at relatively low flow rate, (2) using a heat exchanger wrapped around the tank, through which heating fluid (with finite specific heat) flows from top to bottom, and (3) using an immersed heat element that is relatively high in the tank. Using such methods allows for improved heat pump water heater (HPWH) cycle efficiencies when the heat pump can take advantage of the lower temperatures that exist lower in the tank, and accommodate the resulting glide. Transcritical cycles are especially well-suited to capitalize on this opportunity, and other HPWH configurations (that have been proposed elsewhere) may benefit as well. This work provides several stratification categories of heat pump water heater tank configurations relevant to their stratification potential. To illustrate key differences among categories, it also compiles available experimental data for (a) single pass pumped flow, (b) multi-pass pumped flow, and (c) top-down wrapped tank with transcritical refrigerant.

  18. Water sorption of heat-polymerized acrylic resins processed in mono and bimaxillary flasks

    OpenAIRE

    Meloto, Carolina B.; Silva-Concílio,Laís R.; Machado, Cristiane; Ribeiro,Margarete C.; Joia,Fábio A.; Rizzatti-Barbosa,Célia M.

    2006-01-01

    This study evaluated water sorption in heat-polymerized acrylic resins processed in monomaxillary flasks by water bath and in bimaxillary flasks by microwave energy and water bath. Fifty heat-polymerized acrylic resin specimens were fabricated according to the 12th specification of the American Dental Association and assigned to 3 groups: group 1 was processed by water bath in monomaxillary metallic flask; group 2 was processed by microwave energy in bimaxillary PVC flask; and group 3 was pro...

  19. Possibility of Heat Pump Use in Hot Water Supply Systems

    Directory of Open Access Journals (Sweden)

    Tatyana Babak

    2016-09-01

    The results of this work may be used for in Total Site methodology development allowing heat recovery for district heating needs of both new designs and as retrofits to existing sites to ensure fast, widespread and cost-efficient industrial deployment. It leads to carbon footprint reduction and energy efficiency improvement of regions with heating and cooling demands during winter and summer seasons.

  20. Characteristic of Local Boiling Heat Transfer of Ammonia / Water Binary Mixture on the Plate Type Evaporator

    Science.gov (United States)

    Okamoto, Akio; Arima, Hirofumi; Kim, Jeong-Hun; Akiyama, Hirokuni; Ikegami, Yasuyuki; Monde, Masanori

    Ocean thermal energy conversion (OTEC) and discharged thermal energy conversion (DTEC) are expected to be the next generation energy production systems. Both systems use a plate type evaporator, and ammonia or ammonia/water mixture as a working fluid. It is important to clarify heat transfer characteristic for designing efficient power generation systems. Measurements of local boiling heat transfer coefficients and visualization were performed for ammonia /water mixture (z = 0.9) on a vertical flat plate heat exchanger in a range of mass flux (7.5 - 15 kg/m2s), heat flux (15 - 23 kW/m2), and pressure (0.7 - 0.9 MPa). The result shows that in the case of ammonia /water mixture, the local heat transfer coefficients increase with an increase of vapor quality and mass flux, and decrease with an increase of heat flux, and the influence of the flow pattern on the local heat transfer coefficient is observed.

  1. Numerical Analysis of Lead-Bismuth-Water Direct Contact Boiling Heat Transfer

    Science.gov (United States)

    Yamada, Yumi; Takahashi, Minoru

    Direct contact boiling heat transfer of sub-cooled water with lead-bismuth eutectic (Pb-Bi) was investigated for the evaluation of the performance of steam generation in direct contact of feed water with primary Pb-Bi coolant in upper plenum above the core in Pb-Bi-cooled direct contact boiling water fast reactor. An analytical two-fluid model was developed to estimate the heat transfer numerically. Numerical results were compared with experimental ones for verification of the model. The overall volumetric heat transfer coefficient was calculated from heat exchange rate in the chimney. It was confirmed that the calculated results agreed well with the experimental result.

  2. Experimental performance of a waste heat recovery and utilization system with a looped water-in-steel heat pipe

    Energy Technology Data Exchange (ETDEWEB)

    Habeebullah, M.H.; Akyurt, M.; Najjar, Y.S.H.; El-Kalay, A.K. [King Abdulaziz Univ., Jeddah (Saudi Arabia). College of Engineering

    1998-07-01

    An experimental facility is described for the recovery, by means of heat-pipes, of waste-heat from exhaust gases, and the utilization of the recovered energy to cool ambient air. To this end, heat of combustion gases, generated in a stainless-steel combustion chamber, is recovered from the stack by means of a heat-pipe system. The recovered heat is utilized to run a modified commercial aqua-ammonia absorption chiller. Chilled water from the chiller is supplied to a fan-coil type cooling tunnel to cool the intake air of a (conceptual) gas turbine engine to boost its performance. It is concluded from test results that the experimental facility performs well, and that it behaves as predicted by modeling and simulation studies. The system is able to extract between 70 and 93% of the technically recoverable energy from exhaust gases, and utilizes the extracted energy to cool air. (Author)

  3. Demonstration of a heat pump water heater. Volume 3. Design report

    Energy Technology Data Exchange (ETDEWEB)

    Sloane, B.D.; Krise, R.C.; Kent, D.D.

    1979-12-01

    Work performed during the pilot run manufacturing and laboratory testing stages of a heat pump water heater for residential installations is described. A general description of the heat pump water heater is provided, as are detailed discussions of individual components. Also included is a description of the pilot run manufacturing facility and experience, laboratory operations, and laboratory test data.

  4. The consumptive water footprint of electricity and heat : A global assessment

    NARCIS (Netherlands)

    Mekonnen, Mesfin M.; Gerbens-Leenes, P. W.; Hoekstra, Arjen Y.

    2015-01-01

    Water is essential for electricity and heat production. This study assesses the consumptive water footprint (WF) of electricity and heat generation per world region in the three main stages of the production chain, i.e. fuel supply, construction and operation. We consider electricity from power plan

  5. The consumptive water footprint of electricity and heat: a global assessment

    NARCIS (Netherlands)

    Mekonnen, M.M.; Gerbens-Leenes, P.W.; Hoekstra, A.Y.

    2015-01-01

    Water is essential for electricity and heat production. This study assesses the consumptive water footprint (WF) of electricity and heat generation per world region in the three main stages of the production chain, i.e. fuel supply, construction and operation. We consider electricity from power plan

  6. 16 CFR Appendix D5 to Part 305 - Water Heaters-Heat Pump

    Science.gov (United States)

    2010-01-01

    ... 16 Commercial Practices 1 2010-01-01 2010-01-01 false Water Heaters-Heat Pump D5 Appendix D5 to Part 305 Commercial Practices FEDERAL TRADE COMMISSION REGULATIONS UNDER SPECIFIC ACTS OF CONGRESS RULE... Appendix D5 to Part 305—Water Heaters—Heat Pump Range Information CAPACITY FIRST HOUR RATING Range of...

  7. The consumptive water footprint of electricity and heat: a global assessment

    NARCIS (Netherlands)

    Mekonnen, Mesfin; Gerbens-Leenes, Winnie; Hoekstra, Arjen Ysbert

    2015-01-01

    Water is essential for electricity and heat production. This study assesses the consumptive water footprint (WF) of electricity and heat generation per world region in the three main stages of the production chain, i.e. fuel supply, construction and operation. We consider electricity from power

  8. Comparison of Advanced Residential Water Heating Technologies in the United States

    Energy Technology Data Exchange (ETDEWEB)

    Maguire, J.; Fang, X.; Wilson, E.

    2013-05-01

    Gas storage, gas tankless, condensing, electric storage, heat pump, and solar water heaters were simulated in several different climates across the US installed in both conditioned and unconditioned space and subjected to several different draw profiles. While many preexisting models were used, new models of condensing and heat pump water heaters were created specifically for this work.

  9. Heating and Domestic Hot Water Systems in Buildings Supplied by Low-Temperature District Heating

    DEFF Research Database (Denmark)

    Brand, Marek

    , because less heat is sold to customers and there is higher heat loss in the network. Similarly, higher connection power than needed means bigger pipe diameters are needed, resulting in higher heat losses as well. Using realistic values is therefore very important for feasibility calculations of DH.  ...

  10. Summer Indoor Heat Pump Water Heater Evaluation in a Hot-Dry Climate

    Energy Technology Data Exchange (ETDEWEB)

    Hoeschele, Marc [Alliance for Residential Building Innovation (ARBI), Davis, CA (United States); Seitzler, Matthew [Alliance for Residential Building Innovation (ARBI), Davis, CA (United States)

    2017-05-01

    Heat pump water heaters offer a significant opportunity to improve water heating performance for the over 40% of U.S. households that heat domestic hot water using electric resistance storage water heaters. Numerous field studies have also been completed documenting performance in a variety of climates and applications. More recent evaluation efforts have focused attention on the performance of May through September 2014, with ongoing winter monitoring being sponsored by California utility partners. Summer results show favorable system performance with extrapolated annual water heating savings of 1,466 to 2,300 kWh per year, based on the observed hot water loads. Additional summer space cooling benefits savings of 121 to 135 kWh per year were projected, further increasing the water energy savings.

  11. BOILING OF WATER AND ORGANIC LIQUIDS ON LOW-TEMPERATURE POROUS SURFACES OF HEAT PIPES

    OpenAIRE

    Шаповал, Андрій Андрійович; Панов, Євген Миколайович; Сауліна, Юлія Валеріївна; Романчук, Борис Васильович; Трубійчук, Р. П.

    2015-01-01

    The experimental study results of the influence of porous metal fiber structures on the intensity of two-phase heat transfer of water and acetone boiling on porous surfaces in conditions of free movement and capillary transport of liquids are presented in the article. The experiments were realized using specially designed experimental installation simulated the operating conditions of heat pipes and thermosyphons. Such conditions are typical for two-phase heat transfer devices – heat pipes an...

  12. Cyprus solar water heating cluster: A missed opportunity?

    Energy Technology Data Exchange (ETDEWEB)

    Maxoulis, Christos N. [Cyprus Organisation for Standardisation (CYS) (Cyprus); Cyprus International Institute of Management (CIIM) (Cyprus); Charalampous, Harris P. [Cyprus International Institute of Management (CIIM) (Cyprus); Kalogirou, Soteris A. [Higher Technical Institute, P.O. Box 20423, Nicosia 2152 (Cyprus)]. E-mail: Skalogir@spidernet.com.cy

    2007-06-15

    Cyprus is often called the 'sun island' because of the amount of sunshine received all year round. The abundance of solar radiation together with a good technological base has created favourable conditions for the exploitation of solar energy on the island. This led to the development of a pioneering solar collector industry in Cyprus, which in the mid-1980s was flourishing. The result was an outstanding figure of installed solar collector area per inhabitant. Nowadays, Cyprus is cited as the country with the highest solar collector area installed per inhabitant, worldwide. This means that the local market for solar thermal collectors (for domestic applications) is now rather saturated. It was only rational to assume that Cypriot firms equipped with their gained expertise and leading edge would have safeguarded a sustainable growth and have an international orientation, focusing on exports in an emerging European and eastern Mediterranean thermal solar market. Unfortunately, this is not the case today. This paper reviews the economic performance and the competitiveness of Cyprus and the evolution of the solar water heating (SWH) industry using the cluster theory of Michael Porter. Its aim is to give insight and explanations for the success of the sector domestically, its failure with regards to exporting activity, pinpoint the industry in the European map and finally give recommendations for the cross the boarders commercial success of the industry.

  13. Research on a Household Dual Heat Source Heat Pump Water Heater with Preheater Based on ASPEN PLUS

    Directory of Open Access Journals (Sweden)

    Xiang Gou

    2016-12-01

    Full Text Available This article proposes a dual heat source heat pump bathroom unit with preheater which is feasible for a single family. The system effectively integrates the air source heat pump (ASHP and wastewater source heat pump (WSHP technologies, and incorporates a preheater to recover shower wastewater heat and thus improve the total coefficient of performance (COP of the system, and it has no electric auxiliary heating device, which is favorable to improve the security of the system operation. The process simulation software ASPEN PLUS, widely used in the design and optimization of thermodynamic systems, was used to simulate various cases of system use and to analyze the impact of the preheater on the system. The average COP value of a system with preheater is 6.588 and without preheater it is 4.677. Based on the optimization and analysis, under the standard conditions of air at 25 °C, relative humidity of 70%, wastewater at 35 °C, wastewater flow rate of 0.07 kg/s, tap water at 15 °C, and condenser outlet water temperature at 50 °C, the theoretical COP of the system can reach 9.784 at an evaporating temperature of 14.96 °C, condensing temperature of 48.74 °C, and preheated water temperature of 27.19 °C.

  14. Effects of forced convection of heated air on insensible water loss and heat loss in preterm infants in incubators.

    Science.gov (United States)

    Okken, A; Blijham, C; Franz, W; Bohn, E

    1982-07-01

    To assess the effect of forced convection of heated air exchange in preterm infants in conventional incubators, we measured insensible water loss and total heat loss in preterm infants in a conventional forced convection incubator (air velocity 15 to 25 cm/second) and in a specially constructed still-air incubator (air velocity 0 to 2 cm/second) at equal operative temperature and humidity. Under the forced conditions, insensible water loss in the preterm infants increased by a mean 52% from 1.04 +/- 0.24 (mean +/- SD) to 1.58 +/- 0.51 ml/kg/hour (P less than 0.001). The ensuing increase in evaporative heat loss was partly reflected in the small but significant increase in total heat loss from 1.65 +/- 0.47 to 1.80 +/- 0.44 kcal/kg/hour (P less than 0.02). In the forced convection incubator, the increased evaporative heat loss in preterm infants was apparently partly compensated by a decreased nonevaporative heat loss. If reduction of insensible water loss is required, preterm infants should not be subjected to forced convection in incubators.

  15. Quantifying Systemic Efficiency using Exergy and Energy Analysis for Ground Source Heat Pumps: Domestic Space Conditioning and Water Heating Applications.

    Energy Technology Data Exchange (ETDEWEB)

    Ally, Moonis Raza [ORNL; Baxter, Van D [ORNL; Gehl, Anthony C [ORNL; Munk, Jeffrey D [ORNL

    2017-01-01

    Although air temperatures over land surfaces show wide seasonal and daily variations, the ground, approximately 10 meters below the earth s surface, remains relatively stable in temperature thereby serving as an energy source or sink. Ground source heat pumps can heat, cool, and supply homes with hot water efficiently by utilizing the earth s renewable and essentially inexhaustible energy resources, saving fossil fuels, reducing greenhouse gas emissions, and lowering the environmental footprint. In this paper, evidence is shown that ground source heat pumps can provide up to 79%-87% of domestic hot water energy needs, and up to 77% of space heating needs with the ground s thermal energy resources. The case refers to a 12-month study conducted at a 253 m2 research house located in Oak Ridge, Tennessee, 36.01 N 84.26 W in a mixed-humid climate with HDD of 2218 C-days and CDD of 723 C-days under simulated occupancy conditions. A single 94.5m vertical bore interfaced the heat pump with the ground. The research shows that this technology is capable of achieving US DOE targets of 25 % and 35% energy savings in HVAC, and in water heating, respectively by 2030. It is also a viable technology to meet greenhouse gas target emissions under the IECC 2012 Standard, as well as the European Union (EU) 2020 targets of using renewable energy resources. The paper quantifies systemic efficiencies using Exergy analysis of the major components, clearly pointing areas for further improvement.

  16. Experimental Investigation of Transient Heat Transfer in the Once-Through Boiler Water Separator

    Institute of Scientific and Technical Information of China (English)

    1997-01-01

    The transient heat transfer between working fluid and inner wall of 600 MW supercritical pressure boiler's water separator model during start-up was experimentally explored.The test conditioins for water steam two-phase were as follows:pressure P=3=11MPa,mass flow M=0.2-0.35kg/s,and mass quality x=0.2-0.8;for subcooled water (=3-11MPa,M=0.2-0.35kg/s,and subcooled degree Δθ=10℃.By using an accurate and tracable inverse heat conduction solution,the correlations of single-phase and two-phase transient heat transfer coefficients were obtained.The experimental results demonstrated the heat transfer enhanced for subcooled water and water steam mixture compared with fully developed turbulent flow in tube.The increasing heat transfer effect may be attributed to the deformation or destruction of the boundary layer.

  17. Using Solar Hot Water to Address Piping Heat Losses in Multifamily Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Springer, David [National Renewable Energy Lab. (NREL), Golden, CO (United States); Seitzler, Matt [National Renewable Energy Lab. (NREL), Golden, CO (United States); Backman, Christine [National Renewable Energy Lab. (NREL), Golden, CO (United States); Weitzel, Elizabeth [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2015-10-01

    Solar thermal water heating is most cost effective when applied to multifamily buildings and some states offer incentives or other inducements to install them. However, typical solar water heating designs do not allow the solar generated heat to be applied to recirculation losses, only to reduce the amount of gas or electric energy needed for hot water that is delivered to the fixtures. For good reasons, hot water that is recirculated through the building is returned to the water heater, not to the solar storage tank. The project described in this report investigated the effectiveness of using automatic valves to divert water that is normally returned through the recirculation piping to the gas or electric water heater instead to the solar storage tank. The valves can be controlled so that the flow is only diverted when the returning water is cooler than the water in the solar storage tank.

  18. Using Solar Hot Water to Address Piping Heat Losses in Multifamily Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Springer, David [Alliance for Residential Building Innovation, Davis, CA (United States); Seitzler, Matt [Alliance for Residential Building Innovation, Davis, CA (United States); Backman, Christine [Alliance for Residential Building Innovation, Davis, CA (United States); Weitzel, Elizabeth [Alliance for Residential Building Innovation, Davis, CA (United States)

    2015-10-01

    Solar thermal water heating is most cost effective when applied to multifamily buildings and some states offer incentives or other inducements to install them. However, typical solar water heating designs do not allow the solar generated heat to be applied to recirculation losses, only to reduce the amount of gas or electric energy needed for hot water that is delivered to the fixtures. For good reasons, hot water that is recirculated through the building is returned to the water heater, not to the solar storage tank. The project described in this report investigated the effectiveness of using automatic valves to divert water that is normally returned through the recirculation piping to the gas or electric water heater instead to the solar storage tank. The valves can be controlled so that the flow is only diverted when the returning water is cooler than the water in the solar storage tank.

  19. Sensible heat balance measurements of soil water evaporation beneath a maize canopy

    Science.gov (United States)

    Soil water evaporation is an important component of the water budget in a cropped field. Few methods are available for continuous and independent measurement of soil water evaporation. A sensible heat balance (SHB) approach has recently been demonstrated for continuously determining soil water evapo...

  20. A Novel Absorption Cycle for Combined Water Heating, Dehumidification, and Evaporative Cooling

    Energy Technology Data Exchange (ETDEWEB)

    CHUGH, Devesh [University of Florida, Gainesville; Gluesenkamp, Kyle R [ORNL; Abdelaziz, Omar [ORNL; Moghaddam, Saeed [University of Florida, Gainesville

    2014-01-01

    In this study, development of a novel system for combined water heating, dehumidification, and space evaporative cooling is discussed. Ambient water vapor is used as a working fluid in an open system. First, water vapor is absorbed from an air stream into an absorbent solution. The latent heat of absorption is transferred into the process water that cools the absorber. The solution is then regenerated in the desorber, where it is heated by a heating fluid. The water vapor generated in the desorber is condensed and its heat of phase change is transferred to the process water in the condenser. The condensed water can then be used in an evaporative cooling process to cool the dehumidified air exiting the absorber, or it can be drained if primarily dehumidification is desired. Essentially, this open absorption cycle collects space heat and transfers it to process water. This technology is enabled by a membrane-based absorption/desorption process in which the absorbent is constrained by hydrophobic vapor-permeable membranes. Constraining the absorbent film has enabled fabrication of the absorber and desorber in a plate-and-frame configuration. An air stream can flow against the membrane at high speed without entraining the absorbent, which is a challenge in conventional dehumidifiers. Furthermore, the absorption and desorption rates of an absorbent constrained by a membrane are greatly enhanced. Isfahani and Moghaddam (Int. J. Heat Mass Transfer, 2013) demonstrated absorption rates of up to 0.008 kg/m2s in a membrane-based absorber and Isfahani et al. (Int. J. Multiphase Flow, 2013) have reported a desorption rate of 0.01 kg/m2s in a membrane-based desorber. The membrane-based architecture also enables economical small-scale systems, novel cycle configurations, and high efficiencies. The absorber, solution heat exchanger, and desorber are fabricated on a single metal sheet. In addition to the open arrangement and membrane-based architecture, another novel feature of the

  1. Natural COnvective Heat and Mass Transfer on a Vertical Heated Plate for Water Flow Containing Metal Corrosion Particles

    Institute of Scientific and Technical Information of China (English)

    Pei-xueJiang; Ze-peiRen; 等

    1992-01-01

    Corrosion products of structural materials when contained in water usually are in two states:soluble state and colloidal particles with dimeter about 10-3-10-1um,Deposits of such corrosion products on tube surfaces under high pressure will jeopardize the operating economy of power plant equipment and even esult in accidents.A numerical study is reported in this paper of the natural convective heat and mass transfer on a vertical heated plate subject to the flrst or mixed kind of boundary conditions for high-pressure water(P=17MPa) containing metal corrosion products with consideration of varialbe thermophysical properties.

  2. Exploration of Impinging Water Spray Heat Transfer at System Pressures Near the Triple Point

    Science.gov (United States)

    Golliher, Eric L.; Yao, Shi-Chune

    2013-01-01

    The heat transfer of a water spray impinging upon a surface in a very low pressure environment is of interest to cooling of space vehicles during launch and re-entry, and to industrial processes where flash evaporation occurs. At very low pressure, the process occurs near the triple point of water, and there exists a transient multiphase transport problem of ice, water and water vapor. At the impingement location, there are three heat transfer mechanisms: evaporation, freezing and sublimation. A preliminary heat transfer model was developed to explore the interaction of these mechanisms at the surface and within the spray.

  3. Water Recovery with the Heat Melt Compactor in a Microgravity Environment

    Science.gov (United States)

    Golliher, Eric L.; Goo, Jonathan; Fisher, John

    2015-01-01

    The Heat Melt Compactor is a proposed utility that will compact astronaut trash, extract the water for eventual re-use, and form dry square tiles that can be used as additional ionizing radiation shields for future human deep space missions. The Heat Melt Compactor has been under development by a consortium of NASA centers. The downstream portion of the device is planned to recover a small amount of water while in a microgravity environment. Drop tower low gravity testing was performed to assess the effect of small particles on a capillary-based water/air separation device proposed for the water recovery portion of the Heat Melt Compactor.

  4. Study on performance of a packed bed latent heat thermal energy storage unit integrated with solar water heating system

    Institute of Scientific and Technical Information of China (English)

    NALLUSAMY N.; SAMPATH S.; VELRAJ R.

    2006-01-01

    In thermal systems such as solar thermal and waste heat recovery systems, the available energy supply does not usually coincide in time with the process demand. Hence some form of thermal energy storage (TES) is necessary for the most effective utilization of the energy source. This study deals with the experimental evaluation of thermal performance of a packed bed latent heat TES unit integrated with solar flat plate collector. The TES unit contains paraffin as phase change material (PCM) filled in spherical capsules, which are packed in an insulated cylindrical storage tank. The water used as heat transfer fluid (HTF) to transfer heat from the solar collector to the storage tank also acts as sensible heat storage material. Charging experiments were carried out at varying inlet fluid temperatures to examine the effects of porosity and HTF flow rate on the storage unit performance. The performance parameters such as instantaneous heat stored, cumulative heat stored, charging rate and system efficiency are studied.Discharging experiments were carried out by both continuous and batchwise processes to recover the stored heat, and the results are presented.

  5. Experimental investigation of heat transfer from a 2 × 2 rod bundle to supercritical pressure water

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Han [State Key Laboratory of Multiphase Flow in Power Engineering, Xi’an Jiaotong University, Xi’an 710049 (China); Bi, Qincheng, E-mail: qcbi@mail.xjtu.edu.cn [State Key Laboratory of Multiphase Flow in Power Engineering, Xi’an Jiaotong University, Xi’an 710049 (China); Wang, Linchuan; Lv, Haicai [State Key Laboratory of Multiphase Flow in Power Engineering, Xi’an Jiaotong University, Xi’an 710049 (China); Leung, Laurence K.H. [Atomic Energy of Canada Limited, Chalk River, Ont., Canada K0J 1J0 (Canada)

    2014-08-15

    Highlights: • Heat transfer of supercritical water through a 2 × 2 rod bundles is investigated. • Circumferential wall temperature distribution is obtained. • Effects of system parameters on heat transfer characteristics are analyzed. • Heat transfer correlations are compared against the rod bundle test data. - Abstract: Heat transfer experiments with supercritical pressure water flowing vertically upward through a 2 × 2 rod bundle have been performed at Xi’an Jiaotong University. A fuel-assembly simulator with four heated rods was installed inside a square channel with rounded corner. The outer diameter of each heated rod is 8 mm with an effective heated length of 600 mm. The experiments covered the pressure range of 23–28 MPa, mass-flux range of 350–1000 kg/(m{sup 2} s) and heat-flux range on the rod surface of 200–1000 kW/m{sup 2}. Heat transfer characteristics of supercritical pressure water through the bundle were examined with respect to variations of heat flux, system pressure, and mass flux. These characteristics were shown to be similar to those previously observed in tubes or annuli. The experimental data indicate a non-uniform circumferential wall-temperature distribution around the heated rod. A maximum wall temperature was observed at the surface facing the corner gap between the heated rod and the ceramic tube, while the minimum wall temperature was observed at the surface facing the center subchannel. The difference between maximum and minimum wall temperatures varies with heat flux and/or mass flux. Eight heat transfer correlations developed for supercritical water were assessed against the current set of test data. Prediction of the Jackson correlation agrees closely with the experimental Nusselt number. A new correlation has been derived based on Jackson correlation to improve the prediction accuracy of supercritical heat transfer coefficient in a 2 × 2 rod bundle.

  6. Two-phase experimental heat transfer studies on a water-diesel system in a shell and tube heat exchanger

    Directory of Open Access Journals (Sweden)

    V. Alagesan

    2012-06-01

    Full Text Available Two-phase heat transfer involving two immiscible systems is gaining importance in petrochemical and allied industries. Varying compositions of diesel and water were experimentally studied in a 1:2 shell and tube heat exchanger. The data on pure water and diesel were fitted to an equation of the form. h1φ = a NmRe.The two-phase multiplier, Φ L, was related to the Lockhart Martinelli (L-M parameter, χtt², using the two-phase data and a correlation Φ L = b+c(χtt²+d/(χtt²² was established. The two-phase heat transfer coefficient was calculated based on the coefficients 'a' and 'm' for pure diesel and pure water along with ФL and the L-M parameter. The calculated values of the two-phase heat transfer coefficient h2φ based on pure diesel and pure water suggest that diesel is a better reference fluid since the average error is much smaller compared to pure water as reference.

  7. HEAT TRANSFER OF TiO2/WATER NANOFLUID IN A COILED AGITATED VESSEL WITH PROPELLER

    Institute of Scientific and Technical Information of China (English)

    PERARASU V.T.; ARIVAZHAGAN M.; SIVASHANMUGAM P.

    2012-01-01

    An attempt is made to investigate heat transfer enhancement using nanofluid in a coiled agitated vessel fitted with propeller agitator.The heat transfer coefficient in coiled agitated vessel for water and TiO2/water nanofluid of 3 different volume concentrations (0.10%,0.20% and 0.30%) are estimated and compared.The heat transfer coefficient for nanofluid is found to be higher than that for water and also found to increase with increasing volume concentrations.The enhancement in the convective heat transfer using nanofluid is found to be a maximum of 17.59%.Empirical correlations are separately formed for water and TiO2/water nanofluid as well as found to fit the experimental data within ±5% for water and within ± 10% for nanofluid.

  8. Heat pump using dual heat sources of air and water. Performance with heat sources arranged in parallel; Mizu kuki ryonetsugen heat pump no kenkyu. Netsugen heiretsu unten ni okeru seino

    Energy Technology Data Exchange (ETDEWEB)

    Ito, S.; Miura, N.; Sato, S. [Kanagawa Institute of Technology, Kanagawa (Japan); Uchikawa, Y.; Hamada, K. [Kubota Corp., Osaka (Japan)

    1996-10-27

    A heat pump system using water and air as heat sources was built and evaluated for its performance. In this system, evaporators may be operated singly or as connected in parallel or series, and, for each case, the quantity of heat acquired may be measured and system performance may be quantitatively evaluated. The findings follow. When the two heat sources are equal in temperature in the single-evaporator operation, the evaporation temperature is about 7{degree}C higher on the water side than on the air side, and the performance coefficient is about 0.7 higher. When the air heat source temperature is 25{degree}C in the parallel operation, like quantities of heat are obtained from both heat sources, and collection of heat from the water increases with a decrease in the air heat source temperature but, with an increase, collection from the air increases. When the air heat source temperature decreases, the evaporation temperature decreases in the single-evaporator working on the air and in the parallel operation but it levels off in the single-evaporator working on the water alone. When the water heat source temperature decreases, evaporation temperature drop is sharper in the single-evaporator working on the water than in the parallel operation, which suggests the transfer from the parallel operation to the single-evaporator working on the air. In the single-evaporator operation on the water heat source, the evaporation temperature linearly decreases with an increase in superheating. 1 ref., 10 figs.

  9. Solar heating and hot water system installed at Cherry Hill, New Jersey

    Science.gov (United States)

    1979-01-01

    The solar heating and hot water system installed in existing buildings at the Cherry Hill Inn in Cherry Hill, New Jersey is described in detail. The system is expected to furnish 31.5% of the overall heating load and 29.8% of the hot water load. The collectors are liquid evacuated tube type. The storage system is an above ground insulated steel water tank with a capacity of 7,500 gallons.

  10. Water and heat transport in hilly red soil of southern China: Ⅱ. Modeling and simulation

    Institute of Scientific and Technical Information of China (English)

    LU Jun; HUANG Zhi-zhen; HAN Xiao-fei

    2005-01-01

    Simulation models of heat and water transport have not been rigorously tested for the red soils of southern China.Based on the theory of nonisothermal water-heat coupled transfer, a simulation model, programmed in Visual Basic 6.0, was developed to predict the coupled transfer of water and heat in hilly red soil. A series of soil column experiments for soil water and heat transfer, including soil columns with closed and evaporating top ends, were used to test the simulation model. Results showed that in the closed columns, the temporal and spatial distribution of moisture and heat could be very well predicted by the model,while in the evaporating columns, the simulated soil water contents were somewhat different from the observed ones. In the heat flow equation by Taylor and Lary (1964), the effect of soil water evaporation on the heat flow is not involved, which may be the main reason for the differences between simulated and observed results. The predicted temperatures were not in agreement with the observed one with thermal conductivities calculated by de Vries and Wierenga equations, so that it is suggested that Kh, soil heat conductivity, be multiplied by 8.0 for the first 6.5 h and by 1.2 later on. Sensitivity analysis of soil water and heat coefficients showed that the saturated hydraulic conductivity, Ks, and the water diffusivity, D(θ), had great effects on soil water transport; the variation of soil porosity led to the difference of soil thermal properties, and accordingly changed temperature redistribution,which would affect water redistribution.

  11. Water temperature adjustment in spas by the aid of heat pumps

    Directory of Open Access Journals (Sweden)

    Riznić Dejan T.

    2012-01-01

    Full Text Available Mineral spas are considered an important national resource, used mainly for therapeutical and recreational purposes. However, raw mineral waters are often at temperatures different from the required ones and need to be cooled or heated to be adjusted to the level adequate for a specified purpose. For such an adjustment, energy is either released (when cooling down the mineral water or consumed (for heating up the mineral water. Heat pumps may be used to multiply the gain of energy when released, or reduce the energy needed for heating the water. The report deals with technical possibilities and economic benefits of the use of heat pumps in such case studies in two spas of Serbia, Mataruska spa near Kraljevo, and Bukovicka spa in Arandjelovac.

  12. Domestic Hot Water Production with Ground Source Heat Pump in Apartment Buildings

    Directory of Open Access Journals (Sweden)

    Jukka Yrjölä

    2015-08-01

    Full Text Available Producing domestic hot water (DHW with a ground source heat pump (GSHP is challenging due to the high temperature (HT of DHW. There are many studies proving the better performance of cascade heat pumps compared to single-stage heat pumps when the difference between the condensing and the evaporation temperature is large. In this system approach study, different GSHP arrangements are described and computationally compared. A two-stage heat pump arrangement is introduced in which water tanks of the heating system are utilized for warming up the DHW in two stages. It is shown that the electricity consumption with this two-stage system is approximately 31% less than with the single-stage heat pump and 12% less than with the cascade system. Further, both low temperature (LT and HT heat pumps can run alone, which is not common in cascade or other two-stage heat pumps. This is advantageous because the high loads of the space heating and DHW production are not simultaneous. Proper insulation of the DHW and recirculation pipe network is essential, and drying towel rails or other heating coils should be avoided when aiming for a high efficiency. The refrigerants in the calculations are R407C for the LT heat pump and R134a for the HT heat pump. Investment costs are excluded from calculations.

  13. Solar heating and hot water system installed at office building, One Solar Place, Dallas, Texas

    Science.gov (United States)

    1980-01-01

    A solar heating on cooling system is described which is designed to provide 87 percent of the space heating needs, 100 percent of the potable hot water needs and is sized for future absorption cooling. The collection subsystem consists of 28 solargenics, series 76, flat plate collectors with a total area of 1,596 square feet. The solar loop circulates an ethylene glyco water solution through the collectors into a hot water system exchanger. The water storage subsystem consists of a heat exchanger, two 2,300 gallon concrete hot water storage tanks with built in heat exchangers and a back-up electric boiler. The domestic hot water subsystem sends hot water to the 10,200 square feet floor area office building hot water water fixtures. The building cold water system provides make up to the solar loop, the heating loop, and the hot water concrete storage tanks. The design, construction, cost analysis, operation and maintenance of the solar system are described.

  14. Development and Validation of a Gas-Fired Residential Heat Pump Water Heater - Final Report

    Energy Technology Data Exchange (ETDEWEB)

    Michael Garrabrant; Roger Stout; Paul Glanville; Janice Fitzgerald; Chris Keinath

    2013-01-21

    For gas-fired residential water heating, the U.S. and Canada is predominantly supplied by minimum efficiency storage water heaters with Energy Factors (EF) in the range of 0.59 to 0.62. Higher efficiency and higher cost ($700 - $2,000) options serve about 15% of the market, but still have EFs below 1.0, ranging from 0.65 to 0.95. To develop a new class of water heating products that exceeds the traditional limit of thermal efficiency, the project team designed and demonstrated a packaged water heater driven by a gas-fired ammonia-water absorption heat pump. This gas-fired heat pump water heater can achieve EFs of 1.3 or higher, at a consumer cost of $2,000 or less. Led by Stone Mountain Technologies Inc. (SMTI), with support from A.O. Smith, the Gas Technology Institute (GTI), and Georgia Tech, the cross-functional team completed research and development tasks including cycle modeling, breadboard evaluation of two cycles and two heat exchanger classes, heat pump/storage tank integration, compact solution pump development, combustion system specification, and evaluation of packaged prototype GHPWHs. The heat pump system extracts low grade heat from the ambient air and produces high grade heat suitable for heating water in a storage tank for domestic use. Product features that include conventional installation practices, standard footprint and reasonable economic payback, position the technology to gain significant market penetration, resulting in a large reduction of energy use and greenhouse gas emissions from domestic hot water production.

  15. Numerical thermal analysis of water's boiling heat transfer based on a turbulent jet impingement on heated surface

    Science.gov (United States)

    Toghraie, D.

    2016-10-01

    In this study, a numerical method for simulation of flow boiling through subcooled jet on a hot surface with 800 °C has been presented. Volume fraction (VOF) has been used to simulate boiling heat transfer and investigation of the quench phenomena through fluid jet on a hot horizontal surface. Simulation has been done in a fixed Tsub=55 °C, Re=5000 to Re=50,000 and also in different Tsub =Tsat -Tf between 10 °C and 95 °C. The effect of fluid jet velocity and subcooled temperature on the rewetting temperature, wet zone propagation, cooling rate and maximum heat flux has been investigated. The results of this study show that by increasing the velocity of fluid jet of water, convective heat transfer coefficient at stagnation point increases. More ever, by decreasing the temperature of the fluid jet, convective heat transfer coefficient increases.

  16. Energy savings based on solar heating and improved cooling of the district heating water; Energibesparelser baseret paa solvarme og bedre afkoeling af fjernvarmevandet. Projektrapport

    Energy Technology Data Exchange (ETDEWEB)

    Fafner, K.; Kristjansson, H.; Hansen, Karl Erik

    2009-08-15

    The report analyses and compares the potential for savings in the heat supply, namely use of solar heating and better cooling of the circulating water in the district heating system. The analyses shows that better cooling in the users' heating systems, i.e. lower district heating temperature, should have higher priority than installation of a solar heating system. The report also demonstrates that solar heating continues to have a large un-utilized potential in the Danish heat supply in general, but for the individual building owner installation of a solar heating system will be far more expensive than buying a part of a large-scale solar heating system. However, lowering the return temperature in the district heating transmission pipes is economically more attractive for the building owners than solar heating.

  17. Critical behavior of 2,6-dimethylpyridine-water: Measurements of specific heat, dynamic light scattering, and shear viscosity

    DEFF Research Database (Denmark)

    Mirzaev, S. Z.; Behrends, R.; Heimburg, Thomas Rainer

    2006-01-01

    2,6-dimethylpyridine-water, specific heat, dynamic light scattering, shear viscosity Udgivelsesdato: 14 April......2,6-dimethylpyridine-water, specific heat, dynamic light scattering, shear viscosity Udgivelsesdato: 14 April...

  18. Economic Model Predictive Control for Hot Water Based Heating Systems in Smart Buildings

    DEFF Research Database (Denmark)

    Awadelrahman, M. A. Ahmed; Zong, Yi; Li, Hongwei

    2017-01-01

    This paper presents a study to optimize the heating energy costs in a residential building with varying electricity price signals based on an Economic Model Predictive Controller (EMPC). The investigated heating system consists of an air source heat pump (ASHP) incorporated with a hot water tank...... as active Thermal Energy Storage (TES), where two optimization problems are integrated together to optimize both the ASHP electricity consumption and the building heating consumption utilizing a heat dynamic model of the building. The results show that the proposed EMPC can save the energy cost by load...

  19. Development of a Model for Water and Heat Exchange Between the Atmosphere and a Water Body

    Institute of Scientific and Technical Information of China (English)

    SUN Shufen; YAN Jinfeng; XIA Nan; SUN Changhai

    2007-01-01

    A model for studying the heat and mass exchange between the atmosphere and a water body is developed,in which the phase change process of water freezing in winter and melting in summer and the function of the convective mixing process are taken into consideration. The model uses enthalpy rather than temperature as the predictive variable. It helps to set up governing equations more concisely, to deal with the phase change process more easily, and make the numerical scheme simpler. The model is verified by observed data from Lake Kinneret for a non-frozen lake in summer time, and Lake Lower Two Medicine for a frozen lake in winter time. Reasonably good agreements between the model simulations and observed data indicate that the model can serve as a component for a water body in a land surface model. In order to more efficiently apply the scheme in a climate system model, a sensitivity study of various division schemes with less layers in the vertical direction in the water body is conducted. The results of the study show that the division with around 10 vertical layers could produce a prediction accuracy that is comparable to the fine division with around 40 layers.

  20. Evaluation of Heat Loss and Water Temperature in a Spent Fuel Pit

    Science.gov (United States)

    Yanagi, Chihiro; Murase, Michio; Yoshida, Yoshitaka; Iwaki, Takanori; Nagae, Takashi

    Three-dimensional calculations of ventilation air flow and thermal-hydraulic behavior in a spent fuel pit (SFP) were made using the CFD software, FLUENT6.3.26 to evaluate the heat loss and water temperature in the SFP after shutdown of its cooling systems. The air and water velocities near the water surface were evaluated from the calculated results and referred to conditions of evaporation heat transfer tests, which were carried out at Shinshu University. From the test data, a correlation for evaporation heat fluxes was introduced and incorporated into the calculation of thermal-hydraulic behavior in the SFP. Then, a three-dimensional calculation of thermal-hydraulic behavior in the SFP was done. It was confirmed that the higher the water temperature was, the larger the heat loss from water was, and that the major heat loss was the evaporation heat transfer from the water surface to ventilation air, which was about ten times larger than the heat transfer to concrete walls.

  1. High Efficiency Water Heating Technology Development Final Report, Part II: CO2 and Absorption-Based Residential Heat Pump Water Heater Development

    Energy Technology Data Exchange (ETDEWEB)

    Gluesenkamp, Kyle R. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Abdelaziz, Omar [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Patel, Viral K. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Mandel, Bracha T. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); de Almeida, Valmor F. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2017-05-01

    The two objectives of this project were to 1.demonstrate an affordable path to an ENERGY STAR qualified electric heat pump water heater (HPWH) based on low-global warming potential (GWP) CO2 refrigerant, and 2.demonstrate an affordable path to a gas-fired absorption-based heat pump water heater with a gas energy factor (EF) greater than 1.0. The first objective has been met, and the project has identified a promising low-cost option capable of meeting the second objective. This report documents the process followed and results obtained in addressing these objectives.

  2. Laboratory Test of a Cylindrical Heat Storage Module with Water and Sodium Acetate Trihydrate

    DEFF Research Database (Denmark)

    Dannemand, Mark; Kong, Weiqiang; Johansen, Jakob Berg;

    2016-01-01

    Cylindrical heat storage modules with internal heat exchangers have been tested in a laboratory. The modules were filled with water and sodium acetate trihydrate with additives. The testing focused on the heat content of the storage material and the heat exchange capacity rate during charge...... of the module. For the tests with the phase change materials, the focus was furthermore on the stability of supercooling and cycling stability. Testing the module with sodium acetate trihydrate and 6.4% extra water showed that phase separation increased and the heat released after solidification of supercooled...... phase change material was reduced over 17 test cycles. The heat released after solidification of the supercooled sodium acetate trihydrate with thickening agent and graphite was stable over the test cycles. Stable supercooling was obtained in 7 out of 17 test cycles with the module with sodium acetate...

  3. Influence of the Water-Cooled Heat Exchanger on the Performance of a Pulse Tube Refrigerator

    Directory of Open Access Journals (Sweden)

    Wei Wang

    2017-02-01

    Full Text Available The water-cooled heat exchanger is one of the key components in a pulse tube refrigerator. Its heat exchange effectiveness directly influences the cooling performance of the refrigerator. However, effective heat exchange does not always result in a good performance, because excessively reinforced heat exchange can lead to additional flow loss. In this paper, seven different water-cooled heat exchangers were designed to explore the best configuration for a large-capacity pulse tube refrigerator. Results indicated that the heat exchanger invented by Hu always offered a better performance than that of finned and traditional shell-tube types. For a refrigerator with a working frequency of 50 Hz, the best hydraulic diameter is less than 1 mm.

  4. WEXA: exergy analysis for increasing the efficiency of air/water heat pumps - Final report

    Energy Technology Data Exchange (ETDEWEB)

    Gasser, L.; Wellig, B.; Hilfiker, K.

    2008-04-15

    This comprehensive final report for the Swiss Federal Office of Energy (SFOE) presents the results of a study at the made by the Engineering and Architecture department at the Lucerne University of Applied Sciences and Arts. The subject of the WEXA study (Waermepumpen-Exergie-Analyse - heat pump exergy analysis) is the analysis of the operation of air/water heat-pumps using exergy analysis methods. The basic thermodynamics of heating systems using heat-pumps is discussed. The exergy analyses and exergy balances for the various components and processes of an air/water heat-pump are presented and discussed. Comparisons are presented for heat-pumps with on/off and continuous control systems for their compressors and fans. The paper is concluded with a collection of appendices on the subject.

  5. Effect Mechanism of Structure-Changed Water on Heat Stability of Lysozyme

    Institute of Scientific and Technical Information of China (English)

    赵林; 谭欣

    2003-01-01

    Based on the mechanism of the effect of hydration on the heat stability of lysozyme and the theory of water molecule clusters, the effect of structure-changed water on heat stability of lysozyme has been studied. The results obtained by differential scanning calorimetry (DSC) showed that the thermal denaturation temperature of lysozyme had been elevated 8.47 K through hydration of lysozyme with processed water whose structure had been changed so it was called "structured water" compared to ordinary water. The reason is that structured water changed the dipole moment of water molecules and easily formed cyclic water hexamer or cage-like water hexamer, so that the interacting force of maintaining three-dimensional conformation of lysozyme could be reinforced.

  6. Numerical investigation of Al2O3/water nanofluid laminar convective heat transfer through triangular ducts

    OpenAIRE

    Zeinali Heris, Saeed; Noie, Seyyed Hossein; Talaii, Elham; Sargolzaei, Javad

    2011-01-01

    In this article, laminar flow-forced convective heat transfer of Al2O3/water nanofluid in a triangular duct under constant wall temperature condition is investigated numerically. In this investigation, the effects of parameters, such as nanoparticles diameter, concentration, and Reynolds number on the enhancement of nanofluids heat transfer is studied. Besides, the comparison between nanofluid and pure fluid heat transfer is achieved in this article. Sometimes, because of pressure drop limita...

  7. Turbulent heat exchange between water and ice at an evolving ice-water interface

    CERN Document Server

    Ramudu, Eshwan; Olson, Peter; Gnanadesikan, Anand

    2015-01-01

    We conduct laboratory experiments on the time evolution of an ice layer cooled from below and subjected to a turbulent shear flow of warm water from above. Our study is motivated by observations of warm water intrusion into the ocean cavity under Antarctic ice shelves, accelerating the melting of their basal surfaces. The strength of the applied turbulent shear flow in our experiments is represented in terms of its Reynolds number $\\textit{Re}$, which is varied over the range $2.0\\times10^3 \\le \\textit{Re} \\le 1.0\\times10^4$. Depending on the water temperature, partial transient melting of the ice occurs at the lower end of this range of $\\textit{Re}$ and complete transient melting of the ice occurs at the higher end. Following these episodes of transient melting, the ice reforms at a rate that is independent of $\\textit{Re}$. We fit our experimental measurements of ice thickness and temperature to a one-dimensional model for the evolution of the ice thickness in which the turbulent heat transfer is parameter...

  8. Heat transfer analysis during cooling of die with use of water mist

    Directory of Open Access Journals (Sweden)

    R. Władysiak

    2011-07-01

    Full Text Available The paper presents the results of the heat transfer area during the cooling process of steel test die with water mist which consist the flow of air in the range 150÷350 l/min and 0.05 0.24 l/min of water. Temperature change in the thickness of die by means showing with the thermal curves and the temperature gradient and temperature distribution in the space between the nozzle and the cooled surface of the metal mold using a thermal imaging camera and thermocouples measurement. The course of changes in the temperature gradient and the received heat flux from the die while cooling its with the flow of air and water mist stream. It has been shown that the use of water mist with a variable flow of air and water controls the process of heat transfer process between the permanent molds, and a stream of water mist.

  9. On the development of high temperature ammonia-water hybrid absorption-compression heat pumps

    DEFF Research Database (Denmark)

    Jensen, Jonas Kjær; Markussen, Wiebke Brix; Reinholdt, Lars

    2015-01-01

    Ammonia-water hybrid absorption-compression heat pumps (HACHP) are a promising technology for development of ecient high temperature industrial heat pumps. Using 28 bar components HACHPs up to 100 °C are commercially available. Components developed for 50 bar and 140 bar show that these pressure...

  10. Conventional and advanced exergoenvironmental analysis of an ammonia-water hybridabsorption-compression heat pump

    DEFF Research Database (Denmark)

    Jensen, Jonas Kjær; Markussen, Wiebke Brix; Reinholdt, Lars

    2015-01-01

    The ammonia-water hybrid absorption-compression heat pump (HACHP) is a technology suitable for industrial scale heat pumps in the process industry. A helpful tool in the design of cost effective and low environmental impact energy conversion systems, such as the HACHP, is the application...

  11. Studying heat transfer enhancement for water boiling on a surface with micro- and nanorelief

    Science.gov (United States)

    Kuzma-Kichta, Yu. A.; Lavrikov, A. V.; Shustov, M. V.; Chursin, P. S.; Chistyakova, A. V.; Zvonarev, Yu. A.; Zhukov, V. M.; Vasil'eva, L. T.

    2014-03-01

    We present the results from a study of heat transfer enhancement for bulk water boiling at atmospheric pressure on a surface with micro- and nanorelief, including a relief formed from silicon carbide and aluminum oxide nanoparticles. Horizontally oriented steel tube 1.2 mm in diameter and copper plate 15 × 3 mm in size were selected as test sections. The process was recorded by means of a video camera, and the values of heat transfer, critical heat fluxes, and contact angles were measured. The use of surface with micro- and nanorelief makes it possible to obtain a significantly higher critical heat flux and boiling heat transfer coefficient owing to a change of surface wettability. The results of investigations can find use in compact heat exchangers, refrigerating plants, heat pipes, in the mirrors of high-capacity lasers, in the targets and resonators of charged particle accelerators and for external cooling of reactor vessels under emergency conditions.

  12. Evaluation of water source heat pumps for the Juneau, Alaska Area

    Energy Technology Data Exchange (ETDEWEB)

    Jacobsen, J.J.; King, J.C.; Eisenhauer, J.L.; Gibson, C.I.

    1980-07-01

    The purposes of this project were to evaluate the technical and economic feasibility of water source heat pumps (WSHP) for use in Juneau, Alaska and to identify potential demonstration projects to verify their feasibility. Information is included on the design, cost, and availability of heat pumps, possible use of seawater as a heat source, heating costs with WSHP and conventional space heating systems, and life cycle costs for WSHP-based heating systems. The results showed that WSHP's are technically viable in the Juneau area, proper installation and maintenance is imperative to prevent equipment failures, use of WSHP would save fuel oil but increase electric power consumption. Life cycle costs for WSHP's are about 8% above that for electric resistance heating systems, and a field demonstration program to verify these results should be conducted. (LCL)

  13. Design package for a complete residential solar space heating and hot water system

    Science.gov (United States)

    1978-01-01

    Information necessary to evaluate the design of a solar space heating and hot water system is reported. System performance specifications, the design data brochure, the system description, and other information pertaining to the design are included.

  14. PCM-module to improve hot water heat stores with stratification

    Energy Technology Data Exchange (ETDEWEB)

    Mehling, H.; Hippeli, S.; Hiebler, S. [ZAE Bayern, Garching (Germany); Cabeza, L.F. [Universitat de Lleida (Spain). Centre de Recerca en Energia Aplicada

    2003-04-01

    Hot water heat stores with stratification are a common technology used in solar energy systems and reuse of waste heat. Adding a PCM module at the top of the water tank would give the system higher storage density, and compensate heat loss in the top layer. The work presented here includes experimental results and numerical simulation of the system using an explicit finite-difference method. Experiments and simulations were carried out using different cylindrical PCM modules. With only 1/16 of the volume of the store being PCM, 3/16 of water at the top of the store was held warm for 50% to 200% longer and the average energy density was increased by 20% to 45%. Furthermore, these 3/16 of water were reheated by the heat from the module after being cooled down in only 20 min. (Author)

  15. Titanium-Water Heat Pipe Radiator for Spacecraft Fission Power Project

    Data.gov (United States)

    National Aeronautics and Space Administration — The proposed program will develop titanium/water heat pipes suitable for Spacecraft Fission Power. NASA is examining small fission power reactors for future space...

  16. Heat transfer enhancement in water when used as PCM in thermal energy storage

    Energy Technology Data Exchange (ETDEWEB)

    Cabeza, L.F. [Universitat de Lleida (Spain). Escola Universitaria Politecnica; Mehling, H.; Hiebler, S.; Ziegler, F. [Bavarian Center for Applied Energy Research, Garching (Germany)

    2002-07-01

    Efficient and reliable storage systems for thermal energy are an important requirement in many applications where heat demand and supply or availability do not coincide. Heat and cold stores can basically be divided in two groups. In sensible heat stores the temperature of the storage material is increased significantly. Latent heat stores, on the contrary, use a storage material that undergoes a phase change (PCM) and a small temperature rise is sufficient to store heat or cold. The major advantages of the phase change stores are their large heat storage capacity and their isothermal behavior during the charging and discharging process. However, while unloading a latent heat storage, the solid-liquid interface moves away from the heat transfer surface and the heat flux decreases due to the increasing thermal resistance of the growing layer of the molten/solidified medium. This effect can be reduced using techniques to increase heat transfer. In this paper, three methods to enhance the heat transfer in a cold storage working with water/ice as PCM are compared: addition of stainless steel pieces, copper pieces (both have been proposed before) and a new PCM-graphite composite material. The PCM-graphite composite material showed an increase in heat flux bigger than with any of the other techniques. (Author)

  17. Preparation and Recipe Optimization of Water-based Architectural Heat Insulation Coatings

    Institute of Scientific and Technical Information of China (English)

    CHEN Lijun; SHI Hongxin; XIANG Juping; WU Hongke

    2008-01-01

    Water-based architectural heat insulation coatings were studied to overcome the drawbacks of conventional inorganic silicate heat insulation coatings.The heat insulation coatings were prepared with the method of mechanical agitation when the mixed organic polymer emulsions were used as binder of the coatings and the mixed heat insulating aggregates were applied as powder,and some assistants were also added.Water temperature difference in the plastic container,which was coated with heat insulation coatings,represented the heat-insulating property of the coatings.The influences of components of mixed polymer emulsion,mass ratio of polymer emulsion to powder,particle size of heat insulating aggregates,added amount of air entraining admixture and the match of thickeners on the properties of the coatings were studied.The experimental results show that the heat insulation coatings with good finishing,heat-insulation property and artificial weathering can be prepared when the binder is composed of 66.92% styrene-acrylic emulsion,16.59% elastic emulsion and 16.49% silicone-acrylic emulsion,the mass ratio of polymer emulsion to powder is 0.45,the particle size of heat insulating aggregates is in the rang of 200 and 250 mesh size,the added amount of sericite is 15%,and the added amount of air entraining admixture is in the range of 1.0% and 1.5% and the thickeners are the mixtures of ASE-60 and RM-5000.

  18. Heat Consumption Assessment of the Domestic Hot Water Systems in the Apartment Buildings

    OpenAIRE

    Grasmanis, D; Greķis, A; Talcis, N

    2013-01-01

    This study presents the analysis of energy consumption for domestic hot water in apartment buildings in Riga. The aggregate data contains information about 39 apartment buildings, including heat energy consumption and domestic hot water (DHW) consumption. The analysis is focused on the heat energy consumption in the DHW system. The analysis characterizes the DHW consumption, energy consumption for DHW and energy losses in the DHW systems in apartment buildings.

  19. Heat Consumption Assessment of the Domestic Hot Water Systems in the Apartment Buildings

    OpenAIRE

    Grasmanis, Dzintars; Talcis, Normunds; Greķis, Aldis

    2015-01-01

    This study presents the analysis of energy consumption for domestic hot water in apartment buildings in Riga, Latvia. The aggregate data contains information about 39 apartment buildings, including heat energy consumption and domestic hot water (DHW) consumption. The analysis is focused on the heat energy consumption and seasonal characteristics in the DHW system.The analysis characterizes the DHW consumption, energy consumption for DHW and energy losses in the DHW systems in apartment buildi...

  20. Side-by-Side Testing of Water Heating Systems: Results from the 2013-2014 Evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Colon, Carlos [Florida Solar Energy Center, Cocoa, FL (United States). Bulding America Partnership for Improved Residential Construction

    2017-07-12

    The Florida Solar Energy Center (FSEC) has completed a fourth year-long evaluation on residential hot water heating systems in a laboratory environment (east central Florida, hot-humid climate). This report contains a summary of research activities regarding the evaluation of two residential electric heat pump water heaters (HPWHs), a solar thermal system utilizing a polymer glazed absorber and a high efficiency natural gas system.

  1. Water table tests of proposed heat transfer tunnels for small turbine vanes

    Science.gov (United States)

    Meitner, P. L.

    1974-01-01

    Water-table flow tests were conducted for proposed heat-transfer tunnels which were designed to provide uniform flow into their respective test sections of a single core engine turbine vane and a full annular ring of helicopter turbine vanes. Water-table tests were also performed for the single-vane test section of the core engine tunnel. The flow in the heat-transfer tunnels was shown to be acceptable.

  2. Heat Consumption Assessment of the Domestic Hot Water Systems in the Apartment Buildings

    OpenAIRE

    Grasmanis, D; Greķis, A; Talcis, N

    2013-01-01

    This study presents the analysis of energy consumption for domestic hot water in apartment buildings in Riga. The aggregate data contains information about 39 apartment buildings, including heat energy consumption and domestic hot water (DHW) consumption. The analysis is focused on the heat energy consumption in the DHW system. The analysis characterizes the DHW consumption, energy consumption for DHW and energy losses in the DHW systems in apartment buildings.

  3. Comparison of Advanced Residential Water Heating Technologies in the United States

    Energy Technology Data Exchange (ETDEWEB)

    Maguire, Jeff [National Renewable Energy Lab. (NREL), Golden, CO (United States); Fang, Xia [National Renewable Energy Lab. (NREL), Golden, CO (United States); Wilson, Eric [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2013-05-01

    In this study, gas storage, gas tankless, condensing, electric storage, heat pump, and solar water heaters were simulated in several different climates across the United States, installed in both conditioned and unconditioned space and subjected to several different draw profiles. While many pre-existing models were used, new models of condensing and heat pump water heaters were created specifically for this work. In each case modeled, the whole house was simulated along with the water heater to capture any interactions between the water heater and the space conditioning equipment.

  4. Energetic Efficiency Evaluation by Using GroundWater Heat Pumps

    Directory of Open Access Journals (Sweden)

    Tokar Adriana

    2012-09-01

    Full Text Available Romania has significant energy potential from renewable sources, but the potential used is much lower due to technical and functional disadvantages, to economic efficiency, the cost elements and environmental limitations. However, efforts are being made to integrate renewable energy in the national energy system. To promote and encourage private investments for renewable energy utilization, programs have been created in order to access funds needed to implement these technologies. Assessment of such investments was carried out from technical and economical point of view, by analyzing a heat pump using as heat source the solar energy from the ground.

  5. Recovery of Water from Boiler Flue Gas Using Condensing Heat Exchangers

    Energy Technology Data Exchange (ETDEWEB)

    Levy, Edward; Bilirgen, Harun; DuPont, John

    2011-03-31

    Most of the water used in a thermoelectric power plant is used for cooling, and DOE has been focusing on possible techniques to reduce the amount of fresh water needed for cooling. DOE has also been placing emphasis on recovery of usable water from sources not generally considered, such as mine water, water produced from oil and gas extraction, and water contained in boiler flue gas. This report deals with development of condensing heat exchanger technology for recovering moisture from flue gas from coal-fired power plants. The report describes: • An expanded data base on water and acid condensation characteristics of condensing heat exchangers in coal-fired units. This data base was generated by performing slip stream tests at a power plant with high sulfur bituminous coal and a wet FGD scrubber and at a power plant firing highmoisture, low rank coals. • Data on typical concentrations of HCl, HNO{sub 3} and H{sub 2}SO{sub 4} in low temperature condensed flue gas moisture, and mercury capture efficiencies as functions of process conditions in power plant field tests. • Theoretical predictions for sulfuric acid concentrations on tube surfaces at temperatures above the water vapor dewpoint temperature and below the sulfuric acid dew point temperature. • Data on corrosion rates of candidate heat exchanger tube materials for the different regions of the heat exchanger system as functions of acid concentration and temperature. • Data on effectiveness of acid traps in reducing sulfuric acid concentrations in a heat exchanger tube bundle. • Condensed flue gas water treatment needs and costs. • Condensing heat exchanger designs and installed capital costs for full-scale applications, both for installation immediately downstream of an ESP or baghouse and for installation downstream of a wet SO{sub 2} scrubber. • Results of cost-benefit studies of condensing heat exchangers.

  6. Recovery of Water from Boiler Flue Gas Using Condensing Heat Exchangers

    Energy Technology Data Exchange (ETDEWEB)

    Edward Levy; Harun Bilirgen; John DuPoint

    2011-03-31

    Most of the water used in a thermoelectric power plant is used for cooling, and DOE has been focusing on possible techniques to reduce the amount of fresh water needed for cooling. DOE has also been placing emphasis on recovery of usable water from sources not generally considered, such as mine water, water produced from oil and gas extraction, and water contained in boiler flue gas. This report deals with development of condensing heat exchanger technology for recovering moisture from flue gas from coal-fired power plants. The report describes: (1) An expanded data base on water and acid condensation characteristics of condensing heat exchangers in coal-fired units. This data base was generated by performing slip stream tests at a power plant with high sulfur bituminous coal and a wet FGD scrubber and at a power plant firing high-moisture, low rank coals. (2) Data on typical concentrations of HCl, HNO{sub 3} and H{sub 2}SO{sub 4} in low temperature condensed flue gas moisture, and mercury capture efficiencies as functions of process conditions in power plant field tests. (3) Theoretical predictions for sulfuric acid concentrations on tube surfaces at temperatures above the water vapor dewpoint temperature and below the sulfuric acid dew point temperature. (4) Data on corrosion rates of candidate heat exchanger tube materials for the different regions of the heat exchanger system as functions of acid concentration and temperature. (5) Data on effectiveness of acid traps in reducing sulfuric acid concentrations in a heat exchanger tube bundle. (6) Condensed flue gas water treatment needs and costs. (7) Condensing heat exchanger designs and installed capital costs for full-scale applications, both for installation immediately downstream of an ESP or baghouse and for installation downstream of a wet SO{sub 2} scrubber. (8) Results of cost-benefit studies of condensing heat exchangers.

  7. A Squeeze and Heat Approach to Water Reclamation

    Science.gov (United States)

    2012-05-01

    reserved. Design Tools 5/24/2012 12 2012 NDIA E2S2, New Orleans, LA • System design tools used… – Chemical process simulation, CHEMCAD . – Heat transfer...Results - Chemical Process • Material balance performed for artificial wastewater • Energy balance used – CHEMCAD chemical process simulator for

  8. Characteristics of Vertical Mantle Heat Exchangers for Solar Water Heaters

    DEFF Research Database (Denmark)

    Shah, Louise Jivan; Morrison, G.L.; Behnia, M.

    1999-01-01

    exchangers was also developed for detailed evaluation of the heat flux distribution over the mantle surface. Both the experimental and simulation results indicate that distribution of the flow around the mantle gap is governed by buoyancy driven recirculation in the mantle. The operation of the mantle...

  9. Investigations on heat and momentum transfer in CuO-water nanofluid

    Directory of Open Access Journals (Sweden)

    Dzido Grzegorz

    2015-06-01

    Full Text Available This paper presents results of investigations on the application of CuO-water nanofluids for intensification of convective heat transfer. Performance of nanofluids with 2.2 and 4.0 vol.% CuO NPs (nanoparticles content were examined with regard to heat transfer coefficient and pressure losses in case of turbulent flow in a tube. Negligible impact of examined nanofluid on heat transfer improvement was found. Moreover, measured pressure losses significantly exceeded those determined for primary base liquid. The observations showed that application of nanofluid for heat transfer intensification with a relatively high solid load in the examined flow range is rather controversial.

  10. Visualization Of Water Vaporization During Electrical Heating Process With X-ray Tomography

    Science.gov (United States)

    Wang, Jie; Li, Yubin; Erath, Michael; Kantzas, Apostolos

    2007-06-01

    This paper deals with the study of electrical heating as a potential method for recovery of heavy oil and bitumen from unconsolidated sand formations of Northern Alberta. Electrical heating is a preferred energy transfer method for heating relatively shallow formations containing bitumen with limited support for high-pressure steam injection. Simulation results demonstrated that although electrical heating can contribute to the recovery of oil, substantially more oil would be recovered if the formation or injected water were allowed to boil. Thus the in-situ steam creation has been the target of simulation and experimental work presented here.

  11. Thermal stratification in a hot water tank established by heat loss from the tank

    DEFF Research Database (Denmark)

    on the natural buoyancy resulting in downward flow along the tank side walls due to heat loss of the tank and the influence on thermal stratification of the tank by the downward flow and the corresponding upward flow in the central parts of the tank. Water temperatures at different levels of the tank......Results of experimental and numerical investigations of thermal stratification and natural convection in a vertical cylindrical hot water tank during standby periods are presented. The transient fluid flow and heat transfer in the tank during cooling caused by heat loss are investigated...

  12. Thermal stratification in a hot water tank established by heat loss from the tank

    DEFF Research Database (Denmark)

    Fan, Jianhua; Furbo, Simon

    2009-01-01

    on the natural buoyancy resulting in downward flow along the tank side walls due to heat loss of the tank and the influence on thermal stratification of the tank by the downward flow and the corresponding upward flow in the central parts of the tank. Water temperatures at different levels of the tank......Results of experimental and numerical investigations of thermal stratification and natural convection in a vertical cylindrical hot water tank during standby periods are presented. The transient fluid flow and heat transfer in the tank during cooling caused by heat loss are investigated...

  13. Effect of Microwave Heating on Potato and Tapioca Starches in Water Suspension

    Directory of Open Access Journals (Sweden)

    Nurul Nadiah Ismail

    2016-01-01

    Full Text Available Abstract— The effects of microwave heating on properties of starch were studied on potato and tapioca starches in water suspension at different temperature (50°C and 60°C. Potato and tapioca starches were adjusted to 30% (w/v and heat-moisture treated in a microwave oven and conventional heating.Conventional heating was carried out by direct heating the moisture heated sample at 50ºC and 60ºC while the microwave heating was carried out by microwave oven and the temperature was controlled approximately to 50ºC and 60ºC. The heated starch samples were analyzed for amylose content, pasting properties, swelling and solubility, thermal properties, light microscopy, scanning electron microscopy (SEM and X-ray diffraction. There were present several changes on physicochemical and functional properties of heated starch for both heating methods. However, microwave method gave higher affect on heating treatment rather than conventional heating. Microwave heating was evidenced in affecting pasting properties of potato and tapioca starches by increase the pasting temperature and the paste stability. Microwave heating also significantly increased the amylose content and swelling power but reduced the solubility and enthalpy of gelatinization (ΔH of those starches. There were changes in granule structure of starch observed by loss of birefringence and ruptures granule in SEM micrographs in both heating treatment. A change in the X-ray diffraction pattern from B-type to A-type was occurred in potato starch but tapioca starch shows no changes in X-ray pattern.  

  14. Effect of Microwave Heating on Potato and Tapioca Starches in Water Suspension

    Directory of Open Access Journals (Sweden)

    Nurul Nadiah binti Ismail

    2015-04-01

    Full Text Available The effects of microwave heating on properties of starch were studied on potato and tapioca starches in water suspension at different temperature (50°C and 60°C. Potato and tapioca starches were adjusted to 30% (w/v and heat-moisture treated in a microwave oven and conventional heating.Conventional heating was carried out by direct heating the moisture heated sample at 50oC and 60oC while the microwave heating was carried out by microwave oven and the temperature was controlled approximately to 50oC and 60oC. The heated starch samples were analyzed for amylose content, pasting properties, swelling and solubility, thermal properties, light microscopy, scanning electron microscopy (SEM and X-ray diffraction. There were present several changes on physicochemical and functional properties of heated starch for both heating methods. However, microwave method gave higher affect on heating treatment rather than conventional heating. Microwave heating was evidenced in affecting pasting properties of potato and tapioca starches by increase the pasting temperature and the paste stability. Microwave heating also significantly increased the amylose content and swelling power but reduced the solubility and enthalpy of gelatinization (ΔH of those starches. There were changes in granule structure of starch observed by loss of birefringence and ruptures granule in SEM micrographs in both heating treatment. A change in the X-ray diffraction pattern from B-type to A-type was occurred in potato starch but tapioca starch shows no changes in X-ray pattern.

  15. Observational estimation of heat budgets on drifting ice and open water over the Arctic Ocean

    Institute of Scientific and Technical Information of China (English)

    2003-01-01

    Estimates of the surface heat budget over drifting ice and open water in the Arctic Ocean are made using eddy correlation and flux-profile methods using data obtained from drifting ice and from the R/V Xuelong in the Chinese National Arctic Research Expedition during August 19-24,1999. The results show that the net radiation received by the ice surface is mainly lost through the sensible heat flux and the heat flux due to melting ice, and the latent heat flux making small contribution to the heat balance. However, the heat balance of the open water surface was dominated by the radiative flux whereas the latent and sensible heat fluxes and the oceanic heat flux were greater than those on the sea-ice surface. These results emphasize that thermodynamic processes are quite different between air/open water and air/sea-ice over the Arctic Ocean which is important when considering the effect of sea-air-ice interaction on climate change process during the summer period.

  16. Energy Savings and Breakeven Cost for Residential Heat Pump Water Heaters in the United States

    Energy Technology Data Exchange (ETDEWEB)

    Maguire, J.; Burch, J.; Merrigan, T.; Ong, S.

    2013-07-01

    Heat pump water heaters (HPWHs) have recently reemerged in the U.S. residential water heating market and have the potential to provide homeowners with significant energy savings. However, there are questions as to the actual performance and energy savings potential of these units, in particular in regards to the heat pump's performance in unconditioned space and the impact of the heat pump on space heating and cooling loads when it is located in conditioned space. To help answer these questions, simulations were performed of a HPWH in both conditioned and unconditioned space at over 900 locations across the continental United States and Hawaii. Simulations included a Building America benchmark home so that any interaction between the HPWH and the home's HVAC equipment could be captured. Comparisons were performed to typical gas and electric water heaters to determine the energy savings potential and cost effectiveness of a HPWH relative to these technologies. HPWHs were found to have a significant source energy savings potential when replacing typical electric water heaters, but only saved source energy relative to gas water heater in the most favorable installation locations in the southern US. When replacing an electric water heater, the HPWH is likely to break even in California, the southern US, and parts of the northeast in most situations. However, the HPWH will only break even when replacing a gas water heater in a few southern states.

  17. Energy Savings and Breakeven Costs for Residential Heat Pump Water Heaters in the United States

    Energy Technology Data Exchange (ETDEWEB)

    Maguire, Jeff [National Renewable Energy Lab. (NREL), Golden, CO (United States); Burch, Jay [National Renewable Energy Lab. (NREL), Golden, CO (United States); Merrigan, Tim [National Renewable Energy Lab. (NREL), Golden, CO (United States); Ong, Sean [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2013-07-01

    Heat pump water heaters (HPWHs) have recently re-emerged in the U.S. residential water heating market and have the potential to provide homeowners with significant energy savings. However, there are questions as to the actual performance and energy savings potential of these units, in particular in regards to the heat pump's performance in unconditioned space and the impact of the heat pump on space heating and cooling loads when it is located in conditioned space. To help answer these questions, NREL performed simulations of a HPWH in both conditioned and unconditioned space at over 900 locations across the continental United States and Hawaii. Simulations included a Building America benchmark home so that any interaction between the HPWH and the home's HVAC equipment could be captured. Comparisons were performed to typical gas and electric water heaters to determine the energy savings potential and cost effectiveness of a HPWH relative to these technologies. HPWHs were found to have a significant source energy savings potential when replacing typical electric water heaters, but only saved source energy relative to gas water heater in the most favorable installation locations in the southern United States. When replacing an electric water heater, the HPWH is likely to break even in California, the southern United States, and parts of the northeast in most situations. However, the HPWH will only break even when replacing a gas water heater in a few southern states.

  18. Natural convection heat transfer in vertical triangular subchannel in Zirconia-water nanofluid

    Science.gov (United States)

    Tandian, N. P.; Alkharboushi, A. A. K.; Kamajaya, K.

    2015-09-01

    Natural convection heat transfer in vertical triangular sub-channel has important role in cooling mechanism of the APWR and the PHWR nuclear reactors. Unfortunately, natural convection correlation equations for such geometry are scarcely available. Recent studies showed that ZrO2-water nanofluid has a good prospect to be used in the nuclear reactor technology due to its low neutron absorption cross section. Although several papers have reported transport properties of ZrO2-water nanofluids, practically there is no correlation equation for predicting natural convection heat transfer in a vertical triangular sub-channel in ZrO2-water nanofluid. Therefore, a study for finding such heat transfer correlation equation has been done by utilizing Computational Fluid Dynamics software and reported in this paper. In the study, natural convection heat transfer in a vertical triangular sub-channel has been simulated at several values of heat transfer flux within 9.1 to 30.9 kW/m2 range and ZrO2 concentrations of 0 (pure water), 0.27, and 3 volume-% of ZrO2. The study shows that the ZrO2 concentration has no significant influence to the natural convection heat transfer at those concentration levels. The obtained theoretical heat transfer correlation equations were verified through experiment, and they showed very similar results. The correlation equations are reported in this paper.

  19. Optimization and thermoeconomics research of a large reclaimed water source heat pump system.

    Science.gov (United States)

    Zhang, Zi-ping; Du, Fang-hui

    2013-01-01

    This work describes a large reclaimed water source heat pump system (RWSHPS) and elaborates on the composition of the system and its design principles. According to the characteristics of the reclaimed water and taking into account the initial investment, the project is divided into two stages: the first stage adopts distributed heat pump heating system and the second adopts the combination of centralized and decentralized systems. We analyze the heating capacity of the RWSHPS, when the phase II project is completed, the system can provide hydronic heating water with the supply and return water temperature of 55°C/15°C and meet the hydronic heating demand of 8 million square meters of residential buildings. We make a thermal economics analysis by using Thermal Economics theory on RWSHPS and gas boiler system, it is known that the RWSHPS has more advantages, compared with the gas boiler heating system; both its thermal efficiency and economic efficiency are relatively high. It provides a reference for future applications of the RWSHPS.

  20. Parametric Studies on Buoyancy Induced Flow through Circular Pipes in Solar water heating system

    Directory of Open Access Journals (Sweden)

    Dr. S. V. Prayagi

    2011-01-01

    Full Text Available Solar energy is the primary source of energy for our planet. The average solar energy reaching the earth in the tropical zone is about 1kWh/m2 giving approximately 5 to 10 kWh/m2 per day. Increased utilization of solar energy in India would result in all around benefits, both in term of cleaner environment and monetary gain.The energy from the sun can be used for various purposes such as water heating, water distillation, refrigeration, drying, power generation etc. The present work deals with solar water heating system in particular. Performance of the solar collectors can be determined using the famous Hottel-Whillier-Bliss equation [1]. The analysis is simple for the forced convection situation, where the flow rate is artificially maintained constant to a desired value and the heat transfer coefficient can easily be predicted using the information available in the literature. However the natural convection situation it is very difficult to analyze as appropriate correlations for predicting the values of induced mass flow rate due to thermosiphon effect and the associated heat transfer coefficient are not available. The aim of the present investigation, therefore, is to establish correlations for heat transfer and flow characteristics for the buoyancy induced flow through inclined tubes in case of solar water heating system in particular. Considering the complexity of the problem, experimental approach is preferred. In order to produce required data, experiments were performed using inclined tubes of various lengths, diameters, inclinations, and different heat inputs.

  1. Entropy and Exergy Analysis of a Heat Recovery Vapor Generator for Ammonia-Water Mixtures

    Directory of Open Access Journals (Sweden)

    Kyoung Hoon Kim

    2014-04-01

    Full Text Available Recently power generation systems using ammonia-water binary mixtures as a working fluid have been attracting much attention for their efficient conversion of low-grade heat sources into useful energy forms. This paper presents the First and Second Law thermodynamic analysis for a heat recovery vapor generator (HRVG of ammonia-water mixtures when the heat source is low-temperature energy in the form of sensible heat. In the analysis, key parameters such as ammonia mass concentration and pressure of the binary mixture are studied to investigate their effects on the system performance, including the effectiveness of heat transfer, entropy generation, and exergy efficiency. The results show that the ammonia concentration and the pressure of the mixture have significant effects on the system performance of the HRVG.

  2. Low-energy buildings. Room heating, service water heating, ventilation; Niedrigenergiehaus. Heizung, Warmwasser und Lueftung

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-07-01

    Emissions and primary energy consumption of technical facilities in low-energy buildings are discussed in the ASUE brochure 'Energy consumption and carbon dioxide emissions: Heating systems in low-energy buildings'. This brochure discusses the specific characteristics of heat supply in a low-energy building. It also describes controlled ventilation, the effects of the users' behavour patterns, possibilities of integrating renewables, and examples from heating systems in low-energy single family dwellings to district heating with cogeneration systems. [German] Eine Uebersicht ueber die Emissionen und Primaerenergieverbraeuche verschiedener Systeme im Niedrigenergiehaus gibt die ASUE-Broschuere 'Energieverbrauch und CO{sub 2}-Emissionen: Heizsysteme im Niedrigenergiehaus'. Die vorliegende Broschuere geht auf die geaenderten Anforderungen an die Waermeversorgung in einem Niedrigenergiehaus ein. Die Broschuere stellt ferner die kontrollierte Wohnungslueftung, den Einfluss des Nutzerverhaltens, die Moeglichkeiten zur Einbindung erneuerbarer Energien sowie Beispiele von der Heizung im Niedrigenergie-Einfamilienhaus bis zur Nahwaermeloesung mit Blockheizkraftwerk vor. (orig.)

  3. Buoyancy driven flow in a hot water tank due to standby heat loss

    DEFF Research Database (Denmark)

    Fan, Jianhua; Furbo, Simon

    2012-01-01

    show that the CFD model predicts satisfactorily water temperatures at different levels of the tank during cooling by standby heat loss. It is elucidated how the downward buoyancy driven flow along the tank wall is established by the heat loss from the tank sides and how the natural convection flow......Results of experimental and numerical investigations of thermal behavior in a vertical cylindrical hot water tank due to standby heat loss of the tank are presented. The effect of standby heat loss on temperature distribution in the tank is investigated experimentally on a slim 150l tank...... parts of the tank is measured by experiments and used as input to the CFD model. Water temperatures at different levels of the tank are measured and compared to CFD calculated temperatures. The investigations focus on validation of the CFD model and on understanding of the CFD calculations.The results...

  4. Energy Efficiency Modelling of Residential Air Source Heat Pump Water Heater

    Directory of Open Access Journals (Sweden)

    Cong Toan Tran

    2016-03-01

    Full Text Available The heat pump water heater is one of the most energy efficient technologies for heating water for household use. The present work proposes a simplified model of coefficient of performance and examines its predictive capability. The model is based on polynomial functions where the variables are temperatures and the coefficients are derived from the Australian standard test data, using regression technics. The model enables to estimate the coefficient of performance of the same heat pump water heater under other test standards (i.e. US, Japanese, European and Korean standards. The resulting estimations over a heat-up phase and a full test cycle including a draw off pattern are in close agreement with the measured data. Thus the model allows manufacturers to avoid the need to carry out physical tests for some standards and to reduce product cost. The limitations of the methodology proposed are also discussed.

  5. Heat Losses Evaluation for Domestic Hot Water Distribution Systems

    Directory of Open Access Journals (Sweden)

    Theodor Mateescu

    2006-01-01

    Full Text Available In sanitary systems assembly, domestic hot water distribution supply networks represent an important weight for energetically balance.par This paper presents, in an analytical and graphical manner, the computational tools needed for domestic hot water piping system behavior characterization in different functional and structural assumptions.

  6. Design, Fabrication, and Efficiency Study of a Novel Solar Thermal Water Heating System: Towards Sustainable Development

    Directory of Open Access Journals (Sweden)

    M. Z. H. Khan

    2016-01-01

    Full Text Available This paper investigated a novel loop-heat-pipe based solar thermal heat-pump system for small scale hot water production for household purposes. The effective use of solar energy is hindered by the intermittent nature of its availability, limiting its use and effectiveness in domestic and industrial applications especially in water heating. The easiest and the most used method is the conversion of solar energy into thermal energy. We developed a prototype solar water heating system for experimental test. We reported the investigation of solar thermal conversion efficiency in different seasons which is 29.24% in summer, 14.75% in winter, and 15.53% in rainy season. This paper also discusses the DC heater for backup system and the current by using thermoelectric generator which are 3.20 V in summer, 2.120 V in winter, and 1.843 V in rainy season. This solar water heating system is mostly suited for its ease of operation and simple maintenance. It is expected that such novel solar thermal technology would further contribute to the development of the renewable energy (solar driven heating/hot water service and therefore lead to significant environmental benefits.

  7. Experimental investigation of convective heat transfer enhancement using alumina/water and copper oxide/water nanofluids

    Directory of Open Access Journals (Sweden)

    Mangrulkar Chidanand K.

    2016-01-01

    Full Text Available The nanofluids are widely used for heat transfer applications in the various engineering applications. The nanoparticles dispersed uniformly in the base fluid on proper mixing. In the present study, Al2O3 and CuO nanoparticles were selected and the changes in the heat transfer coefficient were investigated in the complete laminar and discrete points of transition fluid flow through a copper tube with constant heat flux. The heat transfer coefficient was investigated at different loading of Al2O3 and CuO nanopowders ranging from 0.1% to 0.5% of volume concentration in each case for the laminar and transition fluid flow zones, which is then compared with the distilled water as a plain base fluid. It is found that the optimum enhancement in heat transfer is observed at relatively lower volume fraction of nanoparticles ranging between 0.2 to 0.3%.

  8. Nano-porous-water Absorbents for Solid-absorbebt Heat Pump System

    Science.gov (United States)

    Mizota, Tadato; Nakayama, Noriaki

    Zeolite-water heat-pump system has been developed in these 25 years. Recently, an instant beer-cooling system has appeared by using the zeolite heat pump system as a commercial product. It takes so long time for the development since the first proposal. The most serious problem through the development has been of the ability of absorbents. Themaximum heat exchange capacity to date exceeds 1MJ•kg-1 for Mg89-A, which is comparable to the energy storage capacity of modern alkaline-ion batteries in weight-bases. But it needs high temperature heat sources more than 200°C for the activation. Absorbents useful at lower temperatures are thus desirable for effective use of various kinds of lower temperature heat sources Various nano-porous materials as well as zeolites now under investigation as candidates of heat-pump absorbents, such as silica-gels, allophane, imogolite, hydrotalcite, etc.

  9. Numerical and experimental study on heat pump water heater with PCM for thermal storage

    Energy Technology Data Exchange (ETDEWEB)

    Long, Jian-You; Zhu, Dong-Sheng [Key Laboratory of Enhanced Heat Transfer and Energy Conservation of the Ministry of Education, Academy of Chemistry and Energy, South China University of Technology, Guangzhou, Guangdong 510640 (China)

    2008-07-01

    An air source heat pump water heater with phase change material (PCM) for thermal storage was designed to take advantage of off-peak electrical energy. The heat transfer model of PCM was based upon a pure conduction formulation. Quasi-steady state method was used to calculate the temperature distribution and phase front location of PCM during thermal storage process. Temperature and thermal resistance iteration approach has been developed for the analysis of temperature variation of heat transfer fluid (HTF) and phase front location of PCM during thermal release process. To test the physical validity of the calculational results, experimental studies about storing heat and releasing heat of PCM were carried. Comparison between the calculational results and the experimental data shows good agreement. Graphical results including system pressure and input power of heat pump, time-wise variation of stored and released thermal energy of PCM were presented and discussed. (author)

  10. Evaluations of different domestic hot water preparing methods with ultra-low-temperature district heating

    DEFF Research Database (Denmark)

    Yang, Xiaochen; Li, Hongwei; Svendsen, Svend

    2016-01-01

    of Legionella in the DHW (domestic hot water) and assure the comfortable temperature, all substations were installed with supplementary heating devices. Detailed measurements were taken in the substations, including the electricity demand of the supplementary heating devices. To compare the energy and economic...... performance of the substations, separate models were built based on standard assumptions. The relative heat and electricity delivered for preparing DHW were calculated. The results showed that substations with storage tanks and heat pumps have high relative electricity demand, which leads to higher integrated...... costs considering both heat and electricity for DHW preparation. The substations with in-line electric heaters have low relative electricity usage because very little heat is lost due to the instantaneous DHW preparation. Accordingly, the substations with in-line electric heaters would have the lowest...

  11. Performance of a day/night water heat storage system for heating and cooling of semi-closed greenhouses in mild winter climate

    NARCIS (Netherlands)

    Baeza, E.J.; Pérez Parra, J.J.; López, J.C.; Gázquez, J.C.; Meca, D.E.; Stanghellini, C.; Kempkes, F.L.K.; Montero, J.I.

    2012-01-01

    A novel system for heating/cooling greenhouses based on air/water heat exchangers connected to a thermally stratified water storage tank was tested in a small greenhouse compartment at the Experimental Station of the Cajamar Foundation in Almería, Spain. The system maintained a closed greenhouse (no

  12. Ground water heat pumps and cooling with ground water basins as seasonal storage; Grundvandsvarmepumper og -koeling med grundvandsmagasiner som saesonlager

    Energy Technology Data Exchange (ETDEWEB)

    2008-04-15

    Ground water temperature is constant all the year round, in Denmark approximately 9 deg. C, which is ideal for a number of cooling purposes including cooling of buildings. The structures in which the ground water flows (sand, gravel and chalk) are efficient for storing coldness and heat over longer periods. By using seasonal storage of low-temperature heat and coldness in ground water layers close to the terrain it is feasible to reach profitable energy savings of up to 90% for cooling and heating of e.g. hotels, airports, shopping malls, office buildings and other larger buildings. At the same time the large energy savings means major reduction of CO{sub 2} emissions. (BA)

  13. Ground water heat pumps and cooling with ground water basins as seasonal storage; Grundvandsvarmepumper og -koeling med grundvandsmagasiner som saesonlager

    Energy Technology Data Exchange (ETDEWEB)

    2008-04-15

    Ground water temperature is constant all the year round, in Denmark approximately 9 deg. C, which is ideal for a number of cooling purposes including cooling of buildings. The structures in which the ground water flows (sand, gravel and chalk) are efficient for storing coldness and heat over longer periods. By using seasonal storage of low-temperature heat and coldness in ground water layers close to the terrain it is feasible to reach profitable energy savings of up to 90% for cooling and heating of e.g. hotels, airports, shopping malls, office buildings and other larger buildings. At the same time the large energy savings means major reduction of CO{sub 2} emissions. (BA)

  14. Water source heat pumps for greenhouse soil cooling. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Spieser, H.

    1987-06-01

    In an attempt to diversify and grow flowers which are in high demand, growers are looking to produce certain exotic flowers which require unique growing conditions. One example is the Alstroemerias also knwon as the Peruvian Lily. If the plants are grown continuously at about 12-15/sup 0/C soil temperature, the plant will continue to flower regardless of air temperature and photoriod. These latter two factors are considered secondary to the importance of cool soil temperatures. Alstroemeria production is still relatively new to the greenhouse industry. Some controversy still exists as to the direct benefits of planned soil cooling. This project was set up to evaluate a mechanical soil cooling system for continuous year round Alstroemeria production. A heat pump soil cooling system was installed in two greenhouses each with dimensions of 16 m by 61 m. Combined these greenhouses have a growing area of 1952 m/sup 2/. These greenhouses are older wooden greenhouses, covered by double poly, air-inflated glazing. This system worked very well, maintaining the soil temperature at the proper levels throughout the spring and summer months. During the rest of the year the soil cooling system is used less intensely. During winter months when soil cooling is not required, the heat pumps provide base load heating to the greenhouse through fan forced unit heaters.

  15. Soil-water evaporation dynamics determined with measurement of sensible heat transfer

    Science.gov (United States)

    Soil-water evaporation is important in both the hydrologic cycle and the surface energy balance. Yet, routine measurements are unable to capture rapidly shifting near-surface soil heat and water processes involved in evaporation. Recent improvements for fine-scale measurement of soil thermal propert...

  16. Water and heat transport in boreal soils: Implications for soil response to climate change

    Science.gov (United States)

    Fan, Z.; Neff, J.C.; Harden, J.W.; Zhang, T.; Veldhuis, H.; Czimczik, C.I.; Winston, G.C.; O'Donnell, J. A.

    2011-01-01

    Soil water content strongly affects permafrost dynamics by changing the soil thermal properties. However, the movement of liquid water, which plays an important role in the heat transport of temperate soils, has been under-represented in boreal studies. Two different heat transport models with and without convective heat transport were compared to measurements of soil temperatures in four boreal sites with different stand ages and drainage classes. Overall, soil temperatures during the growing season tended to be over-estimated by 2-4??C when movement of liquid water and water vapor was not represented in the model. The role of heat transport in water has broad implications for site responses to warming and suggests reduced vulnerability of permafrost to thaw at drier sites. This result is consistent with field observations of faster thaw in response to warming in wet sites compared to drier sites over the past 30. years in Canadian boreal forests. These results highlight that representation of water flow in heat transport models is important to simulate future soil thermal or permafrost dynamics under a changing climate. ?? 2011 Elsevier B.V.

  17. Theoretical studies on adsorption heat transformer using zeolite-water vapour pair

    Energy Technology Data Exchange (ETDEWEB)

    Chandra, I.; Patwardhan, V.S. (National Chemical Lab., Pune (IN). Chemical Engineering Div.)

    1990-01-01

    An adsorption heat transformer can raise the temperature level of a fraction of waste heat by rejecting the remaining heat to a low temperature level. In this work some alternatives in the design of an adsorption heat transformer, such as a 2-tank system, 3-tank system and 4-tank system, are evaluated using zeolite-water vapour as the adsorbent-adsorbate pair. The values of coefficient of performance (COP) are computed for each system for various temperatures of waste heat source at which the heat is available and heat sink at which the heat is delivered. It is found that an adsorption heat transformer can be used for a gross temperature lift as high as 50{sup 0}C with a fairly good COP value. Moreover the 4-tank system gives a much improved COP value as compared to the 2-tank and 3-tank systems for the same operating conditions. It is also found that the effect of temperature driving force for heat transfer on the COP value is quite pronounced. (author).

  18. Testing and analysis of load-side immersed heat exchangers for solar domestic hot water systems

    Energy Technology Data Exchange (ETDEWEB)

    Farrington, R.B.; Bingham, C.E.

    1987-10-01

    This report describes work to determine the performance of load-side heat exchangers for use in residential solar domestic hot water systems. We measured the performance of four heat exchangers: a smooth coil and a finned coil having heat transfer areas of 2.5 m/sup 2/ (26 ft/sup 2/) and those having areas of 1.7 m/sup 2/ (19 ft/sup 2/). A numerical model using the thermal network program MITAS was constructed, and results were compared to the experimental results. Research showed a smooth coil with only 70% of the surface area of a finned coil performed better than the finned coil. Also, load-side heat exchangers can maintain and enhance stratification in storage tanks, permitting the use of control strategies that take advantage of stratified storage tanks to increase system performance. The analytical model, which agreed reasonably well with the experimental results, was used to vary heat exchanger flow rate and area and initial tank temperature for both a smooth- and a finned-coil heat exchanger. Increasing the heat exchanger flow rate and area results in higher heat transfer rates but not necessarily optimal performance. Lower initial tank temperatures resulted in reduced tank stratification. The smooth heat exchanger outperformed the finned heat exchanger with the same outside surface area. 15 refs., 37 figs., 9 tabs.

  19. Building America Case Study: Indoor Heat Pump Water Heaters During Summer in a Hot-Dry Climate, Redding, California

    Energy Technology Data Exchange (ETDEWEB)

    M. Hoeschele, M. Seitzler

    2017-06-01

    Heat pump water heaters offer a significant opportunity to improve water heating performance for the over 40% of U.S. households that heat domestic hot water using electric resistance storage water heaters. Numerous field studies have also been completed documenting performance in a variety of climates and applications. More recent evaluation efforts have focused attention on the performance of May through September 2014, with ongoing winter monitoring being sponsored by California utility partners.

  20. Solar heating and hot water system installed at Cherry Hill, New Jersey. [Hotels

    Energy Technology Data Exchange (ETDEWEB)

    1979-05-16

    The solar heating and hot water system installed in existing buildings at the Cherry Hill Inn in Cherry Hill, New Jersey is described in detail. The system went into operation November 8, 1978 and is expected to furnish 31.5% of the overall heating load and 29.8% of the hot water load. The collectors are General Electric Company liquid evacuated tube type. The storage system is an above ground insulated steel water tank with a capacity of 7,500 gallons.

  1. Effects of water blowers on service life of combustion chamber heating surfaces

    Energy Technology Data Exchange (ETDEWEB)

    Habryka, A. (Zaklad Techniki Cieplnej i Gospodarki Energetycznej (Poland))

    1990-07-01

    Discusses control of fouling in steam generators of coal-fired power plants and the performance of water jet equipment. Heating surfaces of combustion chambers were monitored by optical probes, industrial television cameras, photo- and film cameras. Continuous observation was accompanied by temperature measurements with thermocouples. Negative effects of water jet application and experience gained in Poland, Estonia and in the FRG concerning periods of cleaning cycles are considered. Improved heating surface cleaning procedures and application of water-jet cleaners of the type used in the Thierbach and Jaenschwalde power plants (FRG) are recommended. 8 refs.

  2. Design for heating radiator of water medium%水媒电暖器的设计

    Institute of Scientific and Technical Information of China (English)

    牟瑛

    2011-01-01

    The water medium radiator is an electric heating device with hot water as heating medium, which relies on the thermal power generated by two upper and lower electric heated tubes to heat the water and control the temperature of water inside the radiator,and makes the hot water circulate naturally by utilizing the features of water density(or specific gravity)and water viscosity( or flowability )under different temperature between supply and return water.The structural design of water medium radiator ensures that the circulating power of water heating system is natural circulated hot-water heating system (circulate based on pressure formed by the weight difference in diverse temperature between supply and return water ).The exhaust holes designed can discharge the air inside the radiator which effectively reduces air retention in radiator.Comparing with central heating and Electric Ting heaters ,the water medium radiator is particularly significant in environmental protection,energy conservation and water conservation.%水媒电暖器是以热水作热媒的电采暖装置.水媒电暖器依靠上下二个电热管产生的热源给水加热,控制散热器内不同位置水的温度,利用供、回水在不同的温度下的水的密度(或比重)、水的黏度(或流动性)的特点使散热器内的水自然循环.水媒电暖器结构设计保证了水采暖系统的循环动力为自然循环热水采暖系统(靠供、回水在不同温度下的重度差形成压力进行循环).设计的出气孔使气体排出散热器内,有效的减少散热器内的空气潴留.水媒电暖器与集中供暖、与电热汀取暖器相比其在环保、节能、节水方面尤为显著.

  3. Creating a Comprehensive Solar Water Heating Deployment Strategy

    Energy Technology Data Exchange (ETDEWEB)

    Focus Marketing Services

    1999-08-18

    This report details the results of a research conducted in 1998 and 1999 and outlines a marketing deployment plan designed for businesses interested in marketing solar water heaters in the new home industry.

  4. Solar space and water heating system installed at Charlottesville, Virginia

    Science.gov (United States)

    1980-01-01

    The solar energy system located at David C. Wilson Neuropsychiatric Hospital, Charlottesville, Virginia, is described. The solar energy system consists of 88 single glazed, Sunworks 'Solector' copper base plate collector modules, hot water coils in the hot air ducts, a Domestic Hot Water (DHW) preheat tank, a 3,000 gallon concrete urethane insulated storage tank and other miscellaneous components. Extracts from the site files, specifications, drawings, installation, operation and maintenance instructions are included.

  5. Solar space and water heating system installed at Charlottesville, Virginia

    Energy Technology Data Exchange (ETDEWEB)

    Greer, Charles R.

    1980-09-01

    The solar energy system located at David C. Wilson Neuropsychiatric Hospital, Charlottesville, Virginia, consists of 88 single glazed, Sunworks Solector copper base plate collector modules; hot water coils in the hot air ducts; a domestic hot water (DHW) preheat tank; a 3,000 gallon concrete urethane-insulated storage tank and other miscellaneous components. This report includes extracts from the site files, specifications, drawings, installation, operation and maintenance instructions.

  6. Solar heating and hot water system installed at Saint Louis, Missouri

    Science.gov (United States)

    1980-01-01

    The solar heating and hot water system installed at the William Tao & Associates, Inc., office building in St. Louis, Missouri is described, including maintenance and construction problems, final drawings, system requirements, and manufacturer's component data. The solar system was designed to provide 50 percent of the hot water requirements and 45 percent of the space heating needs for a 900 sq ft office space and drafting room. The solar facility has 252 sq ft of glass tube concentrator collectors and a 1000 gallon steel storage tank buried below a concrete slab floor. Freeze protection is provided by a propylene glycol/water mixture in the collector loop. The collectors are roof mounted on a variable tilt array which is adjusted seasonally and is connected to the solar thermal storage tank by a tube-in-shell heat exchanger. Incoming city water is preheated through the solar energy thermal storage tank.

  7. Solar heating and hot water system installed at St. Louis, Missouri. Final report

    Energy Technology Data Exchange (ETDEWEB)

    1980-04-01

    Information is provided on the solar heating and hot water system installed at the William Tao and Associates, Inc., office building in St. Louis, Missouri. The information consists of description, photos, maintenance and construction problems, final drawing, system requirements and manufacturer's component data. The solar system was designed to provide 50% of the hot water requirements and 45% of the space heating needs for a 900 square foot office space and drafting room. The solar facility has 252 square foot of glass tube concentrator collectors and a 1000 gallon steel storage tank buried below a concrete slab floor. Freeze protection is provided by a propylene glycol/water mixture in the collector loop. The collectors are roof mounted on a variable tilt array which is adjusted seasonally and is connected to the solar thermal storage tank by a tube-in-shell heat exchanger. Incoming city water is preheated through the solar energy thermal storage tank.

  8. High efficient ammonia heat pump system for industrial process water using the ISEC concept. Part 2

    DEFF Research Database (Denmark)

    Olesen, Martin F.; Madsen, Claus; Olsen, Lars

    2014-01-01

    The Isolated System Energy Charging (ISEC) concept allows for a high efficiency of a heat pump system for hot water production. The ISEC concept consists of two water storage tanks, one charged and one discharged. The charged tank is used for the industrial process, while the discharged tank...... modelling of the heat pump and tank system is performed (in continuation of Part I). The modelling is extended to include the system performance with different natural refrigerants and the influence of different types of compressors....... is charging. The charging of the tank is done by recirculating water through the condenser and thereby gradually heating the water. The modelling of the system is described in Part I [1]. In this part, Part II, an experimental test setup of the tank system is reported, the results are presented and further...

  9. Simultaneous Waste Heat and Water Recovery from Power Plant Flue Gases for Advanced Energy Systems

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Dexin [Gas Technology Inst., Des Plaines, IL (United States)

    2016-12-31

    This final report presents the results of a two-year technology development project carried out by a team of participants sponsored by the Department of Energy (DOE). The objective of this project is to develop a membrane-based technology to recover both water and low grade heat from power plant flue gases. Part of the recovered high-purity water and energy can be used directly to replace plant boiler makeup water as well as improving its efficiency, and the remaining part of the recovered water can be used for Flue Gas Desulfurization (FGD), cooling tower water makeup or other plant uses. This advanced version Transport Membrane Condenser (TMC) with lower capital and operating costs can be applied to existing plants economically and can maximize waste heat and water recovery from future Advanced Energy System flue gases with CO2 capture in consideration, which will have higher moisture content that favors the TMC to achieve higher efficiency.

  10. Performance improvement of wire-bonded mesh screen flat heat pipe using water-based nanofluid

    Science.gov (United States)

    Wang, Ping-Yang; Chen, Yan-Jun; Liu, Zhen-Hua

    2016-12-01

    An experimental study was conducted to investigate the thermal performances of a new type of wire-bonded mesh screen flat heat pipe using water and nanofluid as working fluid to find better structure and the working fluid based on the present flat heat pipes. The influences of the kind of working fluid, mass concentration of nanofluid and operating pressure on the thermal performance of the heat pipe were investigated under the three steady operating pressures. It is found from the results that the thermal performance of wire-bonded mesh screen heat pipe are superior to that of wire-bonded flat heat pipe either using water or using nanofluid as working fluid; the thermal resistance of the former reduces distinctly and the maximum power increases obviously. Moreover, using nanofluid can significantly enhance the thermal performance of this heat pipe; enhanced ratios of the both heat transfer coefficient and maximum heat flux gradually increase with increasing the nanoparticle mass concentration in the nanofluid at the same operating pressure, peaking at the 1.0 wt%. Then, they will gradually reduce with further increase of mass concentration of nanofluid.

  11. Conventional and Advanced Silicagel-water Adsorption Cycles Driven by Near - environmental Temperature Heat

    Science.gov (United States)

    Boelman, Elisa; B. Saha, Bidyut; Tanaka, Aiharu; Kashiwagi, Takao

    This work aims at clarifying the possible operating temperature ranges for silica gel-water adsorption refrigeration cycles driven by near-environmental temperature heat sources (between 50°C and 85°C), with relatively small regenerating temperature lifts (10 K to 65 K). A newly developed three stage advanced silica gel-water cycle, which is operational with 50°C driving heat source and 30°C cooling source is introduced and compared with a conventional single stage cycle. The cycles are evaluated in terms of cooling capacity, COP and the viability of operation with near-environmental temperature driving heat sources. The analysis is based on experimental and cycle simulation work. The results showed the advanced three stage cycle to be particularly suited for operation with low grade waste heat driving sources, since it worked with small regenerating temperature lifts (ΔTregen)of 10K to 30K. Another significant advantage of operation with small ΔTregen is the possibility to reduce irreversible heat losses from batched cycle operation. Experiments carried out on full-size machine suggested that, even with smallΔTregen, adsorber /desorber heat exchanger improvements such as higher thermal conductance and smaller heat capacitance can contribute to reduce heat losses while improving cycle performance in terms of cooling capacity and COP.

  12. Theoretical and Numerical Study of Heat Transfer Deterioration in High Performance Light Water Reactor

    Directory of Open Access Journals (Sweden)

    David Palko

    2008-01-01

    Full Text Available A numerical investigation of the heat transfer deterioration (HTD phenomena is performed using the low-Re k-ω turbulence model. Steady-state Reynolds-averaged Navier-Stokes equations are solved together with equations for the transport of enthalpy and turbulence. Equations are solved for the supercritical water flow at different pressures, using water properties from the standard IAPWS (International Association for the Properties of Water and Steam tables. All cases are extensively validated against experimental data. The influence of buoyancy on the HTD is demonstrated for different mass flow rates in the heated pipes. Numerical results prove that the RANS low-Re turbulence modeling approach is fully capable of simulating the heat transfer in pipes with the water flow at supercritical pressures. A study of buoyancy influence shows that for the low-mass flow rates of coolant, the influence of buoyancy forces on the heat transfer in heated pipes is significant. For the high flow rates, buoyancy influence could be neglected and there are clearly other mechanisms causing the decrease in heat transfer at high coolant flow rates.

  13. Impacts of soil–aquifer heat and water fluxes on simulated global climate

    Directory of Open Access Journals (Sweden)

    N. Y. Krakauer

    2013-05-01

    Full Text Available Climate models have traditionally only represented heat and water fluxes within relatively shallow soil layers, but there is increasing interest in the possible role of heat and water exchanges with the deeper subsurface. Here, we integrate an idealized 50 m deep aquifer into the land surface module of the GISS ModelE general circulation model to test the influence of aquifer–soil moisture and heat exchanges on climate variables. We evaluate the impact on the modeled climate of aquifer–soil heat and water fluxes separately, as well as in combination. The addition of the aquifer to ModelE has limited impact on annual-mean climate, with little change in global mean land temperature, precipitation, or evaporation. The seasonal amplitude of deep soil temperature is strongly damped by the soil–aquifer heat flux. This not only improves the model representation of permafrost area but propagates to the surface, resulting in an increase in the seasonal amplitude of surface air temperature of > 1 K in the Arctic. The soil–aquifer water and heat fluxes both slightly decrease interannual variability in soil moisture and in land-surface temperature, and decrease the soil moisture memory of the land surface on seasonal to annual timescales. The results of this experiment suggest that deepening the modeled land surface, compared to modeling only a shallower soil column with a no-flux bottom boundary condition, has limited impact on mean climate but does affect seasonality and interannual persistence.

  14. Impacts of soil-aquifer heat and water fluxes on simulated global climate

    Directory of Open Access Journals (Sweden)

    N. Y. Krakauer

    2013-01-01

    Full Text Available Climate models have traditionally only represented heat and water fluxes within relatively shallow soil layers, but there is increasing interest in the possible role of heat and water exchanges with the deeper subsurface. Here, we integrate an idealized 50 m deep aquifer into the land surface module of the GISS ModelE general circulation model to test the influence of aquifer-soil moisture and heat exchanges on climate variables. We evaluate the impact on the modeled climate of aquifer-soil heat and water fluxes separately, as well as in combination. The addition of the aquifer to ModelE has limited impact on annual-mean climate, with little change in global mean land temperature, precipitation, or evaporation. The seasonal amplitude of deep soil temperature is strongly damped by the soil-aquifer heat flux. This not only improves the model representation of permafrost area but propagates to the surface, resulting in an increase in the seasonal amplitude of surface air temperature of >1 K in the Arctic. The soil-aquifer water and heat fluxes both slightly decrease interannual variability in soil moisture and land-surface temperature, and decrease the soil moisture memory of the land surface on annual timescales. The results of this experiment suggest that deepening the modeled land surface, compared to modeling only a shallower soil column with a no-flux bottom boundary condition, has limited impact on mean climate but does affect seasonality and interannual persistence.

  15. Effects of optimized root water uptake parameterization schemes on water and heat flux simulation in a maize agroecosystem

    Science.gov (United States)

    Cai, Fu; Ming, Huiqing; Mi, Na; Xie, Yanbing; Zhang, Yushu; Li, Rongping

    2017-04-01

    As root water uptake (RWU) is an important link in the water and heat exchange between plants and ambient air, improving its parameterization is key to enhancing the performance of land surface model simulations. Although different types of RWU functions have been adopted in land surface models, there is no evidence as to which scheme most applicable to maize farmland ecosystems. Based on the 2007-09 data collected at the farmland ecosystem field station in Jinzhou, the RWU function in the Common Land Model (CoLM) was optimized with scheme options in light of factors determining whether roots absorb water from a certain soil layer ( W x ) and whether the baseline cumulative root efficiency required for maximum plant transpiration ( W c ) is reached. The sensibility of the parameters of the optimization scheme was investigated, and then the effects of the optimized RWU function on water and heat flux simulation were evaluated. The results indicate that the model simulation was not sensitive to W x but was significantly impacted by W c . With the original model, soil humidity was somewhat underestimated for precipitation-free days; soil temperature was simulated with obvious interannual and seasonal differences and remarkable underestimations for the maize late-growth stage; and sensible and latent heat fluxes were overestimated and underestimated, respectively, for years with relatively less precipitation, and both were simulated with high accuracy for years with relatively more precipitation. The optimized RWU process resulted in a significant improvement of CoLM's performance in simulating soil humidity, temperature, sensible heat, and latent heat, for dry years. In conclusion, the optimized RWU scheme available for the CoLM model is applicable to the simulation of water and heat flux for maize farmland ecosystems in arid areas.

  16. Effect of Heat Treatment and Digestive Enzymes on Cereal Water-Retention Capacity

    Directory of Open Access Journals (Sweden)

    Rodica Caprita

    2015-10-01

    Full Text Available Thermal treatment of cereal grains affects carbohydrate and micronutrient content and bioavailability. Water-retention capacity (WRC is an important index for the effects of fiber in the diet and the metabolic activity of fiber along the gut. This study evaluated the effect of thermal treatment and digestive enzymes on wheat and barley WRC. Ground wheat and barley samples were heated for different time periods at 150ºC before in vitro gastric and intestinal digestion. WRC values in heat treated wheat and barley are at higher levels as compared to the values of untreated cereals. WRC in barley ranged from 1.026 g water/g DM (untreated to 1.36 g water/g DM (heated at 150ºC for 15 minute. The increase was much lower in heat treated wheat, from 0.973 g water/g DM up to 1.03 g water/g DM at 5 minutes heating time.

  17. Flow patterns and heat convection in a rectangular water bolus for use in superficial hyperthermia.

    Science.gov (United States)

    Birkelund, Yngve; Jacobsen, Svein; Arunachalam, Kavitha; Maccarini, Paolo; Stauffer, Paul R

    2009-07-07

    This paper investigates both numerically and experimentally the spatio-temporal effects of water flow in a custom-made water bolus used for superficial hyperthermia generated by a 915-MHz, 4 x 3 microwave applicator array. Similar hyperthermia models referenced in the literature use a constant water temperature and uniform heat flux to describe conduction and convection energy exchange within the heating apparatus available to cool the tissue surface. The results presented in this paper show that the spatially varying flow pattern and rate are vital factors for the overall heat control applicability of the 5 mm thick bolus under study. Regions with low flow rates and low heat convection clearly put restrictions on the maximum microwave energy possible within the limits of skin temperature rise under the bolus. Our analysis is illustrated by experimental flow front studies using a contrast liquid set-up monitored by high definition video and complemented by numerical analysis of liquid flow and heat exchange within the rectangular water bolus loaded by malignant tissue. Important factors for the improvement of future bolus designs are also discussed in terms of diameter and configuration of the water input and output tubing network.

  18. Water, heat, and airborne pollutants effects on transpiration of urban trees

    Energy Technology Data Exchange (ETDEWEB)

    Wang Hua [State Key Laboratory of Urban and Regional Ecology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085 (China); Ouyang Zhiyun, E-mail: zyouyang@rcees.ac.cn [State Key Laboratory of Urban and Regional Ecology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085 (China); Chen Weiping; Wang Xiaoke; Zheng Hua; Ren Yufen [State Key Laboratory of Urban and Regional Ecology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085 (China)

    2011-08-15

    Transpiration rates of six urban tree species in Beijing evaluated by thermal dissipation method for one year were correlated to environmental variables in heat, water, and pollutant groups. To sort out colinearity of the explanatory variables, their individual and joint contributions to variance of tree transpiration were determined by the variation and hierarchical partitioning methods. Majority of the variance in transpiration rates was associated with joint effects of variables in heat and water groups and variance due to individual effects of explanatory group were in comparison small. Atmospheric pollutants exerted only minor effects on tree transpiration. Daily transpiration rate was most affected by air temperature, soil temperature, total radiation, vapor pressure deficit, and ozone. Relative humidity would replace soil temperature when factors influencing hourly transpiration rate was considered. - Highlights: > Heat, water, pollutants effect on transpiration was evaluated by partitioning method. > Urban tree transpiration was mainly affected by combined effects of these variables. > The heat and water variables affected transpiration of urban trees. > The urban air pollution merely acts as an antagonistic factor. - Heat and water related environmental variables affected transpiration of urban trees and ozone was an added yet minor stress factor.

  19. Solar heating of the produced water of petroleum; Aquecimento solar da agua produzida de petroleo

    Energy Technology Data Exchange (ETDEWEB)

    Santos, Rogerio Pitanga; Chiavone-Filho, Osvaldo; Bezerra, Magna A. Santos; Melo, Josette Lourdes Sousa de; Oliveira, Jackson Araujo de; Ramos, Rafael E. Moura [Universidade Federal do Rio Grande do Norte (UFRN), Natal, RN (Brazil); Schuhli, Juliana Bregenski; Andrade, Vivian Tavares de [PETROBRAS S.A., Rio de Janeiro, RJ (Brazil). Centro de Pesquisas (CENPES)

    2008-07-01

    In this work, experimental data of solar heating for common water and saline solution were measured. The solar heater is formed by a flat-plane collector and a thermal reservoir ('boiler'). The objective is to quantify the variation of fluids' temperature, and correlate it to environment variables, especially solar irradiation. Thereby, it is possible to estimate the solar heating of produced water of petroleum. The solar heater is part of a system of treatment of produced water, and its function is to pre-heat the fluid that enters into the solar distiller, increasing the productivity of distilled water. A saline solution that represents produced water was used in the experiments, using sodium chloride (1000 ppm). The experimental data demonstrates that the solar heater is capable to heat the fluid to temperatures close to 70 deg C, reaching temperatures close to 50 deg C even during cloudy days with low solar radiation. Furthermore, the solar collector energy system provides a higher rate of heating and trough of the thermal reservoir the temperature can remain longer. These are important aspects to the integration with solar distillation. (author)

  20. Evaluation of trigeneration system using microturbine, ammonia-water absorption chiller, and a heat recovery boiler

    Energy Technology Data Exchange (ETDEWEB)

    Preter, Felipe C.; Rocha, Marcelo S.; Simoes-Moreira, Jose Roberto [SISEA - Alternative Energy Systems Lab. Dept. of Mechanical Engineering. University of Sao Paulo (EP/USP), SP (Brazil)], e-mails: felipe.preter@poli.usp.br, msrocha@poli.usp.br, jrsimoes@usp.br; Andreos, Ronaldo [COMGAS - Companhia de Gas de Sao Paulo, SP (Brazil)], e-mail: randreos@comgas.com.br

    2010-07-01

    In this work, a CCHP or tri generation system has been projected, mounted, and tested in laboratory, combining a microturbine for power generation, a heat recovery boiler for hot water production, and an ammonia water absorption chiller for chilled water production. The project was motivated by the large practical applications of this kind of energy recovery system in commerce, and industry, and, in general, more than 85% of the energy source is used as power, hot water, and cold water. In the first part, the trigeneration system theoretical model is detailed, and in the second part, experimental results are presented for different operation conditions. (author)

  1. Thermal Analysis of a Thermal Energy Storage Unit to Enhance a Workshop Heating System Driven by Industrial Residual Water

    National Research Council Canada - National Science Library

    Wenqiang Sun; Zuquan Zhao; Yanhui Wang

    2017-01-01

    .... However, the majority of applicable waste heat resources are high-grade or stable thermal energy, while the low-grade or unstable waste heat resources, especially low-temperature industrial residual water (IRW...

  2. A Mini-channel Heat Exchanger System for Heating, Boiling, and Superheating Water by Radiant Combustion

    Science.gov (United States)

    2007-11-02

    location ( Incropera and DeWitt, 1990; Walas, 1990). Experimental Procedures Experiments were initiated by starting the metering pumps, starting data...0.05*Re* DH ( Incropera and DeWitt, 1990). For the lowest flow rate, the Exh-HX entrance length was xenter = 0.05 * 400 * 0.14 cm = 2.8 cm. For...34 Transactions JSME, Series B, Vol.63, No.6, pp. 871-879, AD 1998. Incropera Frank P. and David P. DeWitt, Fundamentals of Heat and Mass Transfer, 3rd Ed

  3. Thermal Hydraulic Analysis of a Passive Residual Heat Removal System for an Integral Pressurized Water Reactor

    Directory of Open Access Journals (Sweden)

    Junli Gou

    2009-01-01

    Full Text Available A theoretical investigation on the thermal hydraulic characteristics of a new type of passive residual heat removal system (PRHRS, which is connected to the reactor coolant system via the secondary side of the steam generator, for an integral pressurized water reactor is presented in this paper. Three-interknited natural circulation loops are adopted by this PRHRS to remove the residual heat of the reactor core after a reactor trip. Based on the one-dimensional model and a simulation code (SCPRHRS, the transient behaviors of the PRHRS as well as the effects of the height difference between the steam generator and the heat exchanger and the heat transfer area of the heat exchanger are studied in detail. Through the calculation analysis, it is found that the calculated parameter variation trends are reasonable. The higher height difference between the steam generator and the residual heat exchanger and the larger heat transfer area of the residual heat exchanger are favorable to the passive residual heat removal system.

  4. Application of imitation steam'' systems to hot water district heating and cooling systems

    Energy Technology Data Exchange (ETDEWEB)

    Aalto, P.J.; Chen, D.B.

    1991-10-01

    Pequod Associates, Inc. and District Energy St. Paul, Inc. installed a pilot project of an innovative District Heating technology through a contract with the US DOE. This applied research was funded by the Energy Research and Development Act (94--163) for District Heating and Cooling Research. The experimental design is an intervention technique that permits hot water district heating systems to connect to buildings equipped with steam heating systems to connect to buildings equipped with steam heating systems. This method can substantially reduce conversion costs in many older buildings. The method circulates Imitation Steam, which is moist hot air, as a heating medium in standard steam radiators and steam heating coils. Based on the operation of the system during the 1989--90 and 1990--91 winter heating seasons, we conclude the following: the basic concept of using Imitation Steam was proved feasible. The performance of the system can be improved beyond the levels achieved in this installation. Imitation Steam did not cause significant corrosion in the piping system. The technology can be used by other district heating systems to lower conversion costs and increase market penetration. Among the additional benefits from this technology are: eliminating old, inefficient boilers; lower maintenance costs; improved fuel efficiency; reduced emissions.

  5. Simulating water, solute, and heat transport in the subsurface with the VS2DI software package

    Science.gov (United States)

    Healy, R.W.

    2008-01-01

    The software package VS2DI was developed by the U.S. Geological Survey for simulating water, solute, and heat transport in variably saturated porous media. The package consists of a graphical preprocessor to facilitate construction of a simulation, a postprocessor for visualizing simulation results, and two numerical models that solve for flow and solute transport (VS2DT) and flow and heat transport (VS2DH). The finite-difference method is used to solve the Richards equation for flow and the advection-dispersion equation for solute or heat transport. This study presents a brief description of the VS2DI package, an overview of the various types of problems that have been addressed with the package, and an analysis of the advantages and limitations of the package. A review of other models and modeling approaches for studying water, solute, and heat transport also is provided. ?? Soil Science Society of America. All rights reserved.

  6. Solar heating and domestic hot water system installed at Kansas City, Fire Stations, Kansas City, Missouri

    Science.gov (United States)

    1980-01-01

    The solar system was designed to provide 47 percent of the space heating, 8,800 square feet area and 75 percent of the domestic hot water (DHW) load. The solar system consists of 2,808 square feet of Solaron, model 2001, air, flat plate collector subsystem, a concrete box storage subsystem which contains 1,428 cubic feet of 0.5 inch diameter pebbles weighing 71.5 tons, a DHW preheat tank, blowers, pumps, heat exchangers, air ducting, controls and associated plumbing. Two 120 gallon electric DHW heaters supply domestic hot water which is preheated by the solar system. Auxiliary space heating is provided by three electric heat pumps with electric resistance heaters and four 30 kilowatt electric unit heaters. There are six modes of system operation.

  7. Thermal Hydraulic Analysis of a Passive Residual Heat Removal System for an Integral Pressurized Water Reactor

    OpenAIRE

    2009-01-01

    A theoretical investigation on the thermal hydraulic characteristics of a new type of passive residual heat removal system (PRHRS), which is connected to the reactor coolant system via the secondary side of the steam generator, for an integral pressurized water reactor is presented in this paper. Three-interknited natural circulation loops are adopted by this PRHRS to remove the residual heat of the reactor core after a reactor trip. Based on the one-dimensional model and a simulation code (S...

  8. Porous flow of liquid water in Enceladus rock core driven by heterogeneous tidal heating

    Science.gov (United States)

    Choblet, Gael; Tobie, Gabriel; Behounkova, Marie; Cadek, Ondrej

    2016-10-01

    Surface heat flux estimates in excess of 15 GW (e.g. Howett et al., 2016) raise the question of the origin of Enceladus' heat production. While strong heating by tidal dissipation is probably the only viable source, whether the maximum production occurs in the outer ice shell or, deeper, in the ocean or in the rock core, is however unclear. While the analysis of measurements by the Cassini mission (gravity and topography data, observed libration), seems to favor an extremely thin shell at Enceladus South Pole (a few kms only, cf. Thomas et al., 2016, Cadek et al., 2016), the distribution of heat sources remains a major issue in the light of the evolutionary trend that led to this present-day physical state of the moon.Here, we build up on a recent evaluation of tidal deformation in a porous rock core saturated with liquid water indicating that, owing to its unconsolidated state, plausible core rheologies could lead to significant heat production there (typically 20 GW, Tobie et al., in prep.). We describe porous flow in a 3D spherical model following the work of Travis and Schubert (2015). Compaction of the rock matrix is neglected. Water characteristics (density and viscosity), and the bulk thermal conductivity of the porous core are temperature-dependent and the effect of non-water compounds can be considered. Tidal heating is introduced as a heterogeneous heat source with a pattern inferred from numerical models of the tidal response. Our analysis focuses particularly on the heat flux pattern at the ocean/core interface where water is advected in/out of the porous medium.

  9. System design package for IBM system one: solar heating and domestic hot water

    Science.gov (United States)

    1977-01-01

    This report is a collation of documents and drawings that describe a prototype solar heating and hot water system using air as the collector fluid and a pebble bed for heat storage. The system was designed for installation into a single family dwelling. The description, performance specification, subsystem drawings, verification plan/procedure, and hazard analysis of the system was packaged for evaluation of the system with information sufficient to assemble a similar system.

  10. Solar space and water heating system at Stanford University Central Food Services Building. Final report

    Energy Technology Data Exchange (ETDEWEB)

    1980-05-01

    This active hydronic domestic hot water and space heating system was 840 ft/sup 2/ of single-glazed, liquid, flat plate collectors and 1550 gal heat storage tanks. The following are discussed: energy conservation, design philosophy, operation, acceptance testing, performance data, collector selection, bidding, costs, economics, problems, and recommendations. An operation and maintenance manual and as-built drawings are included in appendices. (MHR)

  11. Alternative solutions for inhibiting Legionella in domestic hot water systems based on low-temperature district heating

    DEFF Research Database (Denmark)

    Yang, Xiaochen; Li, Hongwei; Svendsen, Svend

    2015-01-01

    Abstract District heating is a cost-effective way of providing heat to high heat density areas. Low-temperature district heating (LTDH) is a promising way to make district heating more energy-efficient and adaptable to well-insulated buildings with low heating demand in the future. However, one....... The alternative design approach can eliminate the risk factors of Legionella by local temperature boosting and restricting system volume. Decentralized substations, micro heat pumps, electric heating elements and electric heat tracing are all investigated as alternative designs. With regard to sterilization...... systems. They have the additional benefit of reducing the heat loss of the hot water system. The alternative design solutions both enrich our options for water sanitation and improve the energy efficiency of our energy systems....

  12. Solar heating, cooling, and hot water systems installed at Richland, Washington

    Science.gov (United States)

    1979-01-01

    The project described is part of the U. S. Department of Energy's solar demonstration program, and became operational in April 1978. The solar system uses 6,000 square feet of flat-plate liquid collectors in a closed loop to deliver solar energy through a liquid-liquid heat exchanger to the building heat-pump duct work or 9,000-gallon thermal energy storage tank. A 25-ton Arkla solar-driven absorption chiller provides the cooling, in conjunction with a 2,000 gallon chilled water storage tank and reflective ponds on three sides of the building surplus heat. A near-by building is essentially identical except for having conventional heat-pump heating and cooling, and can serve as an experimental control. An on-going public relations program was provided from the beginning of the program, and resulted in numerous visitors and tour groups.

  13. Effect of water content and heating temperature on thermal properties of brown rice batter

    Science.gov (United States)

    Aboukzail, Jehan; Abdullah, Aminah; Ghani, Maaruf Abd

    2015-09-01

    The objectives of this research were to assess the effect of water content in the formulation (60%,80%, 100%, 105%, 110%, 120% flour basis) on starch gelatinization of brown rice batter, and to identify the effects of heat treatment at 50°C, 60°C, 70°C, 80°C on starch gelatinization and degree of starch gelatinization of brown rice batter and wheat dough. At 60% water content, there was no gelatinization of brown rice batter, but the batter was gelatinized by increasing the water content to 80%. No significant differences in onset (To) peak (Tp) and endest (Tend) temperature when the water content increased from 80% to 120%; however, enthalpy (ΔH) decreased when water content grew up. Heat treatment of brown rice batter at 60% water content made brown rice batter gelatinized. Starch gelatinization temperature To, Tend and ΔH did not have significant differences when temperature of heat treatment increased from 50°C to 80°C while Tp increased significantly (p<0.05) at 80°C. However, heat treatment had more effect on wheat dough compared to brown rice batter.

  14. Heating Water with Solar Energy Costs Less at the Phoenix Federal Correctional Institution

    Energy Technology Data Exchange (ETDEWEB)

    None

    2004-09-01

    A large solar thermal system installed at the Phoenix Federal Correctional Institution (FCI) in 1998 heats water for the prison and costs less than buying electricity to heat that water. This renewable energy system provides 70% of the facility's annual hot water needs. The Federal Bureau of Prisons did not incur the up-front cost of this system because it was financed through an Energy Savings Performance Contract (ESPC). The ESPC payments are 10% less than the energy savings so that the prison saves an average of $6,700 per year, providing an immediate payback. The solar hot water system produces up to 50,000 gallons of hot water daily, enough to meet the needs of 1,250 inmates and staff who use the kitchen, shower, and laundry facilities. This publication details specifications of the parabolic trough solar system and highlights 5 years of measured performance data.

  15. Field experiment on coalmine heat disaster governance using cold source from surface water

    Institute of Scientific and Technical Information of China (English)

    Guo Pingye; Zhu Guolong; Liu Yuqing; Duan Mengmeng; Wu Junyin

    2014-01-01

    Regarding the lack of cold source for underground cooling systems from either mine inflow or return air, field experiments were taken in a high temperature deep coal mine with abundant cold source from surface water. Taking Sanhejian coal mine as an example, this paper introduced the technology scheme of heat disaster governance using surface water cold source. The paper presents the basics of this field experiment at the beginning, following by the design and site layout of the cooling system including the analysis and calculation of cold source. Numerical calculation method is also applied based on the operation parameters to simulate the influence to the surface river ecosystem. The results suggest that the temperature of surface water shall be lower than 34 ?C after heat exchange, and when more cooling capacities are needed in the future, increasing the water flow is more favorable than increasing the cooling range of water, which is better for the ecological environment protection.

  16. Development of Absorption Heat Pump Driven by Low Temperature Hot Water

    Science.gov (United States)

    Hoshida, Toshihiro; Nakamura, Naoto; Asai, Hiroshi; Hasatani, Masanobu; Watanabe, Fujio; Fujisawa, Ryou

    We developed an Adsorption Heat Pump (AHP) system, which applies silica-gel as adsorbent and H2O as refrigerant, and is possibly intended to use low temperature hot water (333K) as a driving force. The growing importance to save energy, leads us to develop energy saving systems such as Co-generation systems, including fuel cell system. It is important to use low temperature hot water in order to achieve high efficiency in total. It is, however, noticed that the lower water temperature is, the more difficult its' heat recovery becomes. We reported experimental results of the AHP system, and estimated the possibility to apply low temperature hot water from fuel cell system to the AHP system. We showed quantitatively that the AHP system is able to be driven by low temperature hot water(333K).

  17. Experimental studies on seasonal heat storage based on stable supercooling of a sodium acetate water mixture

    DEFF Research Database (Denmark)

    Furbo, Simon; Dragsted, Janne; Fan, Jianhua

    2011-01-01

    to transfer heat to and from the module have been tested. Further, a solidification start method, based on a strong cooling of a small part of the salt water mixture in the module by boiling CO2 in a small brass tank in good thermal contact to the outer side of the module wall, has been tested. Tests......Laboratory tests of a 230 l seasonal heat storage module with a sodium acetate water mixture have been carried out. The aim of the tests is to elucidate how best to design a seasonal heat storage based on the salt water mixture, which supercools in a stable way. The module can be a part...... of a seasonal heat storage, that will be suitable for solar heating systems which can fully cover the yearly heat demand of Danish low energy buildings. The tested module has approximately the dimensions 2020 mm x 1285 mm x 80 mm. The module material is steel and the wall thickness is 2 mm. Different methods...

  18. Regional heat loss in resting man during immersion in 25.2 degrees C water.

    Science.gov (United States)

    Wade, C E; Dacanay, S; Smith, R M

    1979-06-01

    Five male subjects having a wide range of relative body fat, 9.2-20.2%, were studied during total body immersion in water at 25.2 degrees C. The regional surface area of each subject was calculated from anthropometric data utilizing a segmental geometric model. Skin temperatures (Tsk) and regional skin heat loss were measured prior to and during 30 min immersion at 13 sites. During immersion, mean Tsk was 25.9 degrees C and remained significantly higher than the water temperature. A measurable temperature gradient for heat flow was observed from all body segments. Segimental temperature in water ranged from 26.7-25.4 degrees C, being warmest at the neck and coolest at the foot. Heat the flow per regional area was highest in the neck, 187 W/m2, and least at the foot, 12 W/m2. Heat flow from each body region was dependent on regional Tsk. Skinfold thickness was a minor factor in altering regional heat flow in the foot, hand, lower arm, upper arm, thigh, and calf; in the torso, neck, and head regions it was of major importance in detering heat loss.

  19. Electron beam heating effects during environmental scanning electron microscopy imaging of water condensation on superhydrophobic surfaces

    Science.gov (United States)

    Rykaczewski, K.; Scott, J. H. J.; Fedorov, A. G.

    2011-02-01

    Superhydrophobic surfaces (SHSs) show promise as promoters of dropwise condensation. Droplets with diameters below ˜10 μm account for the majority of the heat transferred during dropwise condensation but their growth dynamics on SHS have not been systematically studied. Due to the complex topography of the surface environmental scanning electron microscopy is the preferred method for observing the growth dynamics of droplets in this size regime. By studying electron beam heating effects on condensed water droplets we establish a magnification limit below which the heating effects are negligible and use this insight to study the mechanism of individual drop growth.

  20. Performance and heat transfer characteristics of HFC-134a and CFC-12 in a water chiller

    Energy Technology Data Exchange (ETDEWEB)

    Devotta, S.; Parande, M.G.; Patwardhan, V.R. [National Chemical Lab., Pune (India)

    1998-07-01

    A water chiller with an open reciprocating compressor has been used to comparatively assess the performance of HFC-134a with reference to CFC-12 under as close to identical conditions as possible. Performance characteristics of the chiller under retrofit conditions show that HFC-134a offers better cooling load and coefficients of performance vis-a-vis CFC-12 for identical operating conditions. Further heat transfer analysis of data for the condenser shows that the condensing heat transfer coefficients for HFC-134a are superior to CFC-12. The better performance of HFC-134a may be ascribed to the better heat transfer coefficient of HFC-134a over CFC-12. (Author)

  1. Heat transfer performance of silver/water nanofluid in a solar flat-plate collector

    OpenAIRE

    Lazarus, Godson; Roy, Siddharth; Kunhappan, Deepak; Cephas, Enoch; Wongwises, Somchai

    2015-01-01

    An experimental study is carried out to investigate the heat transfer characteristics of silver/water nanofluid in a solar flatplate collector. The solar radiation heat flux varies between 800 W/m2and 1000W/m2, and the particle concentration varies between 0.01%, 0.03%, and 0.04%. The fluid Reynolds number varies from 5000 to 25000. The influence of radiation heat flux, mass flow rate of nanofluid, inlet temperature into the solar collector, and volume concentration of the particle on the con...

  2. Low-temperature water reactor for the district heating atomic power plant

    Energy Technology Data Exchange (ETDEWEB)

    Skvortsov, S.A.; Sokolov, I.N.; Krauze, L.V.; Nikiporetz, Yu.G.; Philimonov, Y.V.

    1978-04-01

    A natural convection low-pressure water reactor can be utilized as a source of district heating. This provides inherent safety factors under conditions requiring emergency core cooling. The reactor pressure vessel is contained within a prestressed concrete shell, both of which are designed to withstand accident overpressure. This also results in a relatively thin-walled reactor vessel that can be fabricated on-site. The overall safety and economy of such a system merits further consideration as a system for providing low-temperature nuclear heat for district heating.

  3. Advanced Energy and Water Recovery Technology from Low Grade Waste Heat

    Energy Technology Data Exchange (ETDEWEB)

    Dexin Wang

    2011-12-19

    The project has developed a nanoporous membrane based water vapor separation technology that can be used for recovering energy and water from low-temperature industrial waste gas streams with high moisture contents. This kind of exhaust stream is widely present in many industrial processes including the forest products and paper industry, food industry, chemical industry, cement industry, metal industry, and petroleum industry. The technology can recover not only the sensible heat but also high-purity water along with its considerable latent heat. Waste heats from such streams are considered very difficult to recover by conventional technology because of poor heat transfer performance of heat-exchanger type equipment at low temperature and moisture-related corrosion issues. During the one-year Concept Definition stage of the project, the goal was to prove the concept and technology in the laboratory and identify any issues that need to be addressed in future development of this technology. In this project, computational modeling and simulation have been conducted to investigate the performance of a nanoporous material based technology, transport membrane condenser (TMC), for waste heat and water recovery from low grade industrial flue gases. A series of theoretical and computational analyses have provided insight and support in advanced TMC design and experiments. Experimental study revealed condensation and convection through the porous membrane bundle was greatly improved over an impermeable tube bundle, because of the membrane capillary condensation mechanism and the continuous evacuation of the condensate film or droplets through the membrane pores. Convection Nusselt number in flue gas side for the porous membrane tube bundle is 50% to 80% higher than those for the impermeable stainless steel tube bundle. The condensation rates for the porous membrane tube bundle also increase 60% to 80%. Parametric study for the porous membrane tube bundle heat transfer

  4. A numerical model for water and heat transport in freezing soils with nonequilibrium ice-water interfaces

    Science.gov (United States)

    Peng, Zhenyang; Tian, Fuqiang; Wu, Jingwei; Huang, Jiesheng; Hu, Hongchang; Darnault, Christophe J. G.

    2016-09-01

    A one-dimensional numerical model of heat and water transport in freezing soils is developed by assuming that ice-water interfaces are not necessarily in equilibrium. The Clapeyron equation, which is derived from a static ice-water interface using the thermal equilibrium theory, cannot be readily applied to a dynamic system, such as freezing soils. Therefore, we handled the redistribution of liquid water with the Richard's equation. In this application, the sink term is replaced by the freezing rate of pore water, which is proportional to the extent of supercooling and available water content for freezing by a coefficient, β. Three short-term laboratory column simulations show reasonable agreement with observations, with standard error of simulation on water content ranging between 0.007 and 0.011 cm3 cm-3, showing improved accuracy over other models that assume equilibrium ice-water interfaces. Simulation results suggest that when the freezing front is fixed at a specific depth, deviation of the ice-water interface from equilibrium, at this location, will increase with time. However, this deviation tends to weaken when the freezing front slowly penetrates to a greater depth, accompanied with thinner soils of significant deviation. The coefficient, β, plays an important role in the simulation of heat and water transport. A smaller β results in a larger deviation in the ice-water interface from equilibrium, and backward estimation of the freezing front. It also leads to an underestimation of water content in soils that were previously frozen by a rapid freezing rate, and an overestimation of water content in the rest of the soils.

  5. Solar heating, cooling, and hot water systems installed at Richland, Washington. Final report

    Energy Technology Data Exchange (ETDEWEB)

    1979-06-01

    Project Sunburst is a demonstration system for solar space heating and cooling and solar hot water heating for a 14,400 square foot office building in Richland, Washington. The project is part of the US Department of Energy's solar demonstration program, and became operational in April 1978. The solar system uses 6,000 square feet of flat-plate liquid collectors in a closed loop to deliver solar energy through a liquid--liquid heat exchanger to the building heat-pump duct work or 9,000-gallon thermal energy storage tank. A 25-ton Arkla solar-driven absorption chiller provides the cooling, in conjunction with a 2,000 gallon chilled water storage tank and reflective ponds on three sides of the building to reject surplus heat. A near-by building is essentially identical except for having conventional heat-pump heating and cooling, and can serve as an experimental control. An on-going public relations program has been provided from the beginning of the program and has resulted in numerous visitors and tour groups.

  6. Simulation of MHD CuO–water nanofluid flow and convective heat transfer considering Lorentz forces

    Energy Technology Data Exchange (ETDEWEB)

    Sheikholeslami, Mohsen; Bandpy, Mofid Gorji [Department of Mechanical Engineering, Babol University of Technology, Babol (Iran, Islamic Republic of); Ellahi, R., E-mail: rellahi@engr.ucr.edu [Department of Mechanical Engineering, University of California Riverside (United States); Department of Mathematics and Statistics, FBAS, IIUI, H-10 Sector, Islamabad (Pakistan); Zeeshan, A. [Department of Mathematics and Statistics, FBAS, IIUI, H-10 Sector, Islamabad (Pakistan)

    2014-11-15

    Magnetic field effect on CuO–water nanofluid flow and heat transfer in an enclosure which is heated from below is investigated. Lattice Boltzmann method is applied to solve the governing equations. The effective thermal conductivity and viscosity of nanofluid are calculated by KKL (Koo–Kleinstreuer–Li) correlation. In this model effect of Brownian motion on the effective thermal conductivity is considered. Effect of active parameter such as: Hartmann number, heat source length, nanoparticle volume fraction and Rayleigh numbers on the flow and heat transfer characteristics have been examined. The results reveal that the enhancement in heat transfer increases as Hartmann number and heat source length increase but it decreases with increase of Rayleigh number. Also it can be found that effect of Hartmann number and heat source length is more pronounced at high Rayleigh number. - Highlights: • This paper analyses the magnetic effect on CuO–water nanofluid. • Koo–Kleinstreuer–Li correlation and Lattice Boltzmann method are used. • Effects of pertinent parameters are presented through tables and graphs.

  7. Identifying (subsurface) anthropogenic heat sources that influence temperature in the drinking water distribution system

    Science.gov (United States)

    Agudelo-Vera, Claudia M.; Blokker, Mirjam; de Kater, Henk; Lafort, Rob

    2017-09-01

    The water temperature in the drinking water distribution system and at customers' taps approaches the surrounding soil temperature at a depth of 1 m. Water temperature is an important determinant of water quality. In the Netherlands drinking water is distributed without additional residual disinfectant and the temperature of drinking water at customers' taps is not allowed to exceed 25 °C. In recent decades, the urban (sub)surface has been getting more occupied by various types of infrastructures, and some of these can be heat sources. Only recently have the anthropogenic sources and their influence on the underground been studied on coarse spatial scales. Little is known about the urban shallow underground heat profile on small spatial scales, of the order of 10 m × 10 m. Routine water quality samples at the tap in urban areas have shown up locations - so-called hotspots - in the city, with relatively high soil temperatures - up to 7 °C warmer - compared to the soil temperatures in the surrounding rural areas. Yet the sources and the locations of these hotspots have not been identified. It is expected that with climate change during a warm summer the soil temperature in the hotspots can be above 25 °C. The objective of this paper is to find a method to identify heat sources and urban characteristics that locally influence the soil temperature. The proposed method combines mapping of urban anthropogenic heat sources, retrospective modelling of the soil temperature, analysis of water temperature measurements at the tap, and extensive soil temperature measurements. This approach provided insight into the typical range of the variation of the urban soil temperature, and it is a first step to identifying areas with potential underground heat stress towards thermal underground management in cities.

  8. Occurrence and pathogenicity of Naegleria fowleri in artificially heated waters

    Energy Technology Data Exchange (ETDEWEB)

    Sykora, J.L.; Keleti, G.; Martinez, A.J.

    1983-03-01

    The occurrence of pathogenic Naegleria fowleri in thermal discharges, recipient waters, and cooling towers of eight power plants located in western Pennsylvania was investigated for 2 years in conjunction with several environmental measurements. Pathogenic N. fowleri was detected in one cooling tower and in the discharge, receiving waters, or both of five of eight localities. The occurrence of this organism was related to elevated temperatures, but no significant correlation was found for other biological and chemical parameters. Laboratory experiments on the effect of pH on pathogenic N. fowleri documented 100% survival at a range from 2.1 to 8.15. Higher pH reduced or killed the amoebae. No case of human primary amoebic meningoencephalitis occurred during the study.

  9. Building America Case Study: Indoor Heat Pump Water Heaters During Summer in a Hot-Dry Climate, Redding, California

    Energy Technology Data Exchange (ETDEWEB)

    2017-06-15

    Heat pump water heaters offer a significant opportunity to improve water heating performance for the over 40% of U.S. households that heat domestic hot water using electric resistance storage water heaters. Numerous field studies have also been completed documenting performance in a variety of climates and applications. More recent evaluation efforts have focused attention on the performance of May through September 2014, with ongoing winter monitoring being sponsored by California utility partners. Summer results show favorable system performance with extrapolated annual water heating savings of 1,466 to 2,300 kWh per year, based on the observed hot water loads. Additional summer space cooling benefits savings of 121 to 135 kWh per year were projected, further increasing the water heating savings by 5-9%. Given the project schedule for 2014 completion, no heating season impacts were able to be monitored. May through September 2014, with ongoing winter monitoring being sponsored by California utility partners. Summer results show favorable system performance with extrapolated annual water heating savings of 1,466 to 2,300 kWh per year, based on the observed hot water loads. Additional summer space cooling benefits savings of 121 to 135 kWh per year were projected, further increasing the water heating savings by 5-9%. Given the project schedule for 2014 completion, no heating season impacts were able to be monitored.

  10. Solar Heating of Buildings and Domestic Hot Water. Revision.

    Science.gov (United States)

    1980-05-01

    gaseous state. These engines operate on various cycles, including the Stirling and Brayton cycles. For relatively low thermal energy input temperatures...are air and water. The basic concept is to dehu- midify air with a desiccant, evaporatively cool the dehumidified air, and * regenerate the desiccant... regenerating it for continuation of the process. Desiccant systems have faced problems of high parasitic power and large space requirements relative to

  11. Energy-effective method for low-temperature deaeration of make-up water on the heating supply system of heat power plants

    Science.gov (United States)

    Sharapov, V. I.; Pazushkina, O. V.; Kudryavtseva, E. V.

    2016-01-01

    The technology for low-temperature deaeration of make-up water of heating supply systems is developed that makes it possible to substantially enhance the energy efficiency of heat power plants (HPPs). As a desorbing agent for deaeration of make-up water of heating supply systems, it is proposed to use not steam or superheated water but a gas supplied to boiler burners. Natural gas supplied to steam boilers of HPPs has very low or often negative temperature after reducing devices. At the same time, it is virtually corrosive gas-free (oxygen and carbon dioxide) and, therefore, can be successfully used as the desorbing agent for water deaeration. These factors make it possible to perform deaeration of make-up water of heating supply systems at relatively low temperatures (10-30°C). Mixing of the cold deaerated make-up water with the return delivery water results in a significant decrease in the temperature the return delivery water before a lower delivery heater of a dual-purpose turbine plant, increase in the power output with the heat consumption, and, consequently, enhancement in the operation efficiency of the HPP. The article presents the calculation of the consumption of gas theoretically required for deaeration and reveals the evaluation of the energy efficiency of the technology for a typical energy unit of thermal power station. The mass transfer efficiency of the deaeration of the make-up water of heating supply systems is estimated for the case of using natural gas as the desorbing agent for which the specific gas consumption required theoretically for deaeration is calculated. It is shown that the consumption of natural gas used as fuel in boilers of HPPs is sufficient for the deaeration of any volumes of the make-up water of heating supply systems. The energy efficiency of the developed technology is evaluated for a typical heat power-generating unit of the HPP with a T-100-12.8 turbine. The calculation showed that the application of the new technology

  12. Water and heat transport in hilly red soil of southern China: I. Experiment and analysis

    Institute of Scientific and Technical Information of China (English)

    LU Jun; HUANG Zhi-zhen; HAN Xiao-fei

    2005-01-01

    Studies on coupled transfer of soil moisture and heat have been widely carried out for decades. However, little work has been done on red soils, widespread in southern China. The simultaneous transfer of soil moisture and heat depends on soil physical properties and the climate conditions. Red soil is heavy clay and high content of free iron and aluminum oxide. The climate conditions are characterized by the clear four seasons and the serious seasonal drought. The great annual and diurnal air temperature differences result in significant fluctuation in soil temperature in top layer. The closed and evaporating columns experiments with red soil were conducted to simulate the coupled transfer of soil water and heat under the overlaying and opening fields' conditions, and to analyze the effects of soil temperature gradient on the water transfer and the effects of initial soil water contents on the transfer of soil water and heat. The closed and evaporating columns were designed similarly with about 18 ℃ temperatures differences between the top and bottom boundary, except of the upper end closed or exposed to the air, respectively.Results showed that in the closed column, water moved towards the cold end driven by temperature gradient, while the transported water decreased with the increasing initial soil water content until the initial soil water content reached to field capacity equivalent,when almost no changes for the soil moisture profile. In the evaporating column, the net transport of soil water was simultaneously driven by evaporation and temperature gradients, and the drier soil was more influenced by temperature gradient than by evaporation. In drier soil, it took a longer time for the temperature to reach equilibrium, because of more net amount of transported water.

  13. Development of High Efficiency Carbon Dioxide Commercial Heat Pump Water Heater

    Energy Technology Data Exchange (ETDEWEB)

    Michael PETERSEN; Chad D. BOWERS; Stefan ELBEL; Pega HRNJAK

    2012-07-01

    Although heat pump water heaters are today widely accepted in both Japan and Europe, where energy costs are high and government incentives for their use exist, acceptance of such products in the US has been limited. While this trend is slowly changing with the introduction of heat pump water heaters into the residential market, but acceptance remains low in the commercial sector. The objective of the presented work is the development of a high efficiency R744 heat pump water heater for commercial applications with effective utilization of the cooling capability for air conditioning and/or refrigeration. The ultimate goal is to achieve total system COP of up to 8. This unit will be targeted at commercial use where some cooling load is typically needed year round, such as restaurants, hotels, nursing homes, and hospitals. This paper presents the performance results from the development of four R744 commercial heat pump water heater packages of approximately 35 kW and comparison to a commercially available baseline R134a unit of the same capacity and footprint. In addition, the influences of an internal heat exchanger and an enhanced evaporator on the system performance are described and recommendations are made for further improvements of the R744 system.

  14. Simulation of one-sided heating of boiler unit membrane-type water walls

    Science.gov (United States)

    Kurepin, M. P.; Serbinovskiy, M. Yu.

    2017-03-01

    This study describes the results of simulation of the temperature field and the stress-strain state of membrane-type gastight water walls of boiler units using the finite element method. The methods of analytical and standard calculation of one-sided heating of fin-tube water walls by a radiative heat flux are analyzed. The methods and software for input data calculation in the finite-element simulation, including thermoelastic moments in welded panels that result from their one-sided heating, are proposed. The method and software modules are used for water wall simulation using ANSYS. The results of simulation of the temperature field, stress field, deformations and displacement of the membrane-type panel for the boiler furnace water wall using the finite-element method, as well as the results of calculation of the panel tube temperature, stresses and deformations using the known methods, are presented. The comparison of the known experimental results on heating and bending by given moments of membrane-type water walls and numerical simulations is performed. It is demonstrated that numerical results agree with high accuracy with the experimental data. The relative temperature difference does not exceed 1%. The relative difference of the experimental fin mutual turning angle caused by one-sided heating by radiative heat flux and the results obtained in the finite element simulation does not exceed 8.5% for nondisplaced fins and 7% for fins with displacement. The same difference for the theoretical results and the simulation using the finite-element method does not exceed 3% and 7.1%, respectively. The proposed method and software modules for simulation of the temperature field and stress-strain state of the water walls are verified and the feasibility of their application in practical design is proven.

  15. Two-phase mixture simulation of Al{sub 2}O{sub 3}/water nanofluid heat transfer in a non-uniform heat addition test section

    Energy Technology Data Exchange (ETDEWEB)

    Abbassi, Yasser; Shirani, Amir Saeed [Shahid Beheshti Univ., Teheran (Iran, Islamic Republic of). Dept. of Engineering

    2016-11-15

    Results of a numerical investigation of Al{sub 2}O{sub 3}/Water nanofluid heat transfer are presented. The two-phase mixture model is used to study the effects of Reynolds number and nanoparticle concentrations on nanofluid heat transfer in flow around an annulus test section. Non-uniform heat flux is assumed as heat boundary condition on annuli inner wall. Annuli wall and bulk temperature profiles, Local and averaged heat transfer coefficient profiles, local and averaged Nusselt number profiles are presented as functions of nanoparticle volume concentrations and Reynolds numbers. Both laminar and turbulent flow regimes are simulated.

  16. Effect of Ducted HPWH on Space-Conditioning and Water Heating Energy Use -- Central Florida Lab Home

    Energy Technology Data Exchange (ETDEWEB)

    Colon, Carlos [Florida Solar Energy Center, Cocoa, FL (United States); Martin, Eric [Florida Solar Energy Center, Cocoa, FL (United States); Parker, Danny [Florida Solar Energy Center, Cocoa, FL (United States)

    2016-11-01

    The purpose of this research is to investigate the impact of ducted heat pump water heaters (HPWH's) on space conditioning and water heating energy use in residential applications. Two identical HPWH's, each of 60 gallon capacity were tested side by side at the Flexible Residential Test facility (FRTF) laboratories of the Florida Solar Energy Center (FSEC) campus in Cocoa, Florida. The water heating experiments were run in each test house from July 2014 until February 2015.

  17. Effect of Ducted HPWH on Space-Conditioning and Water Heating Energy Use -- Central Florida Lab Home

    Energy Technology Data Exchange (ETDEWEB)

    Colon, Carlos [Building America Partnership for Improved Residential Construction, Cocoa, FL (United States); Martin, Eric [Building America Partnership for Improved Residential Construction, Cocoa, FL (United States); Parker, Danny [Building America Partnership for Improved Residential Construction, Cocoa, FL (United States)

    2016-11-01

    The purpose of this research is to investigate the impact of ducted heat pump water heaters (HPWHs) on space conditioning and water heating energy use in residential applications. Two identical HPWHs, each of 60 gallon capacity were tested side by side at the Flexible Residential Test facility (FRTF) laboratories of the Florida Solar Energy Center (FSEC) campus in Cocoa, Florida. The water heating experiments were run in each test house from July 2014 until February 2015.

  18. The Effect of Heat on Structural Characteristics and Water Absorption Behavior of Agave Fibers

    Science.gov (United States)

    Saikia, Dip

    2008-04-01

    The structural characteristics and water absorptions behavior agave fibers were investigated over a range of temperature by using XRD, IR, TG and gravimetric methods. Three distinct thermal processes were observed during heating the fiber in the temperature range 310-760 K in air, oxygen and nitrogen invariably. The cellulose structures of the fibers were unaffected on heating up to 450 K. The samples showed thermal decomposition processes beyond 500 K. Fibers displayed a two-stage diffusion behavior. The structural parameters and kinetic of water absorption of the fibers at specific temperatures were analyzed.

  19. Influence of surface roughness and porosity of inclusion in water droplet on heat transfer enhancement

    Directory of Open Access Journals (Sweden)

    Borisova Anastasia G.

    2016-01-01

    Full Text Available Using high-speed camera, the experiments were performed to research evaporation of 10 μl water droplets containing 2 mm solid inclusions in the shape of cube, when heated (up to 850 K in combustion products of technical ethanol. Adding solid inclusions in water droplets allowed considerably decreasing (by 70% their evaporation times. Also, the artificial irregularities (roughness and porosity at the surfaces of solid inclusions were manufactured to increase heat transfer area. Such approach enabled to decrease evaporation times of heterogeneous liquid droplets in high-temperature gases by 40% (when comparing inclusions with artificial irregularities and smooth surface.

  20. On the development of high temperature ammonia-water hybrid absorption-compression heat pumps

    DEFF Research Database (Denmark)

    Jensen, Jonas Kjær; Markussen, Wiebke Brix; Reinholdt, Lars;

    2015-01-01

    Ammonia-water hybrid absorption-compression heat pumps (HACHP) are a promising technology for development of ecient high temperature industrial heat pumps. Using 28 bar components HACHPs up to 100 °C are commercially available. Components developed for 50 bar and 140 bar show that these pressure ......, and 140 bar up to 147 °C. If the compressor discharge temperature limit is increased to 250 °C and the vapour water content constraint is removed, this becomes: 182 °C, 193 °C and 223 °C....

  1. Experimental investigation of heat transfer during severe accident of a Pressurized Heavy Water Reactor with simulated decay heat generation in molten pool inside calandria vessel

    Energy Technology Data Exchange (ETDEWEB)

    Prasad, Sumit Vishnu, E-mail: svprasad@barc.gov.in; Nayak, Arun Kumar, E-mail: arunths@barc.gov.in

    2016-07-15

    Highlights: • Scaled test facility simulating the calandria vessel and calandria vault water of PHWR with simulated decay heat was built. • Experiments conducted with simulant material at about 1200 °C. • Experimental result shows that melt coolability and growth rate of crust thickness are affected by presence of decay heat. • No gap was observed between the crust and vessel on opening. • Result shows that vessel integrity is intact with presence of water inside water tank in both cases. - Abstract: The present study focuses on experimental investigation in a scaled facility of an Indian PHWR to investigate the coolability of molten corium with simulated decay heat in the simulated calandria vessel. Molten borosilicate glass was used as the simulant due to its comparable heat transfer characteristics similar to prototypic material. About 60 kg of the molten material was poured into the test section at about 1200 °C. Decay heat in the melt pool was simulated using four high watt heaters cartridges, each having 9.2 kW. The temperature distributions inside the molten pool, across the vessel wall thickness and vault water were measured. Experimental results obtained are compared with the results obtained previously for no decay heat case. The results indicated that presence of decay heat seriously affects the coolability behaviour and formation of crust in the melt pool. The location and magnitude of maximum heat flux and surface temperature of the vessel also are affected in the presence of decay heat.

  2. Solar heating, cooling and domestic hot water system installed at Columbia Gas System Service Corporation, Columbus, Ohio

    Science.gov (United States)

    1980-01-01

    The solar energy system installed in the building has 2,978 sq ft of single axis tracking, concentrating collectors and provides solar energy for space heating, space cooling and domestic hot water. A 1,200,000 Btu/hour water tube gas boiler provides hot water for space heating. Space cooling is provided by a 100 ton hot water fired absorption chiller. Domestic hot water heating is provided by a 50 gallon natural gas domestic storage water heater. Extracts from the site files, specification references, drawings, installation, operation and maintenance instructions are included.

  3. Solar heating, cooling and domestic hot water system installed at Columbia Gas System Service Corp. , Columbus, Ohio. Final report

    Energy Technology Data Exchange (ETDEWEB)

    None

    1980-11-01

    The Solar Energy System located at the Columbia Gas Corporation, Columbus, Ohio, has 2978 ft/sup 2/ of Honeywell single axis tracking, concentrating collectors and provides solar energy for space heating, space cooling and domestic hot water. A 1,200,000 Btu/h Bryan water-tube gas boiler provides hot water for space heating. Space cooling is provided by a 100 ton Arkla hot water fired absorption chiller. Domestic hot water heating is provided by a 50 gallon natural gas domestic storage water heater. Extracts are included from the site files, specification references, drawings, installation, operation and maintenance instructions.

  4. Numerical investigation of Al2O3/water nanofluid laminar convective heat transfer through triangular ducts

    Directory of Open Access Journals (Sweden)

    Zeinali Heris Saeed

    2011-01-01

    Full Text Available Abstract In this article, laminar flow-forced convective heat transfer of Al2O3/water nanofluid in a triangular duct under constant wall temperature condition is investigated numerically. In this investigation, the effects of parameters, such as nanoparticles diameter, concentration, and Reynolds number on the enhancement of nanofluids heat transfer is studied. Besides, the comparison between nanofluid and pure fluid heat transfer is achieved in this article. Sometimes, because of pressure drop limitations, the need for non-circular ducts arises in many heat transfer applications. The low heat transfer rate of non-circular ducts is one the limitations of these systems, and utilization of nanofluid instead of pure fluid because of its potential to increase heat transfer of system can compensate this problem. In this article, for considering the presence of nanoparticl: es, the dispersion model is used. Numerical results represent an enhancement of heat transfer of fluid associated with changing to the suspension of nanometer-sized particles in the triangular duct. The results of the present model indicate that the nanofluid Nusselt number increases with increasing concentration of nanoparticles and decreasing diameter. Also, the enhancement of the fluid heat transfer becomes better at high Re in laminar flow with the addition of nanoparticles.

  5. Heat-induced destabilization of oil-in-water emulsions formed from hydrolyzed whey protein.

    Science.gov (United States)

    Euston, S R; Finnigan, S R; Hirst, R L

    2001-11-01

    The emulsifying ability, heat stability, and coalescence stability of oil-in-water emulsions prepared with whey protein of varied degrees of hydrolysis (DH), and at varied protein contents, was studied. Whey protein hydrolysates (WPH) with a DH of 4% and 10% had poorer emulsifying ability than non-hydrolyzed whey protein concentrate (WPC), but were more heat stable. Increasing DH between 10 and 27% improved emulsifying ability and further improved the heat stability of the emulsion droplets. Increasing DH from 27 to 35% led to a big decrease in both emulsifying ability and heat stability. The quiescent coalescence stability of WPH emulsions was relatively good up to a DH of 27%. Above DH 27% emulsions become highly unstable. It appears that two mechanisms of instability are at work here. At low DH heat-induced denaturation and aggregation occur. In the DH range of 4-20% heat stability increases as protein globular structure is disrupted. At a DH greater than 27% we see a change from a hydrolysis-induced increase in heat-stability to coalescence instability, with a resultant large increase in emulsion breakdown during heating.

  6. Heat Transfer Coefficient between Ice Cover and Water in the Bohai Sea

    Institute of Scientific and Technical Information of China (English)

    季顺迎; 岳前进; 毕祥军

    2001-01-01

    The calculative method of heat transfer coefficient between ice cover and water is analyzed considering the heat balance at ice cover bottom firstly. The heat transfer coefficient is calculated with the meteorological, oceanographic data and sea ice conditions measured on the JZ20-2 Oil/Gas Platform in the Bohai Sea during the winter of 1997/1998. From the results, it is shown that the heat transfer coefficient is smaller in the freezing and melting periods, which is about 0.16× 10-3 and 0.04× 10-3 respectively. In the middle of ice season, the heat transfer coefficient has a larger value, which is about 0.5 × 10-3. Lastly, the influences of ice thickness and ice type on the heat transfer coefficient are discussed. With the heat transfer coefficient determined above, the oceanic heat flux in the winter of 1997~1998 is calculated, and its trend in the winter is analyzed. This study can be referenced in the sea ice numerical simulation and prediction in the Bohai Sea.

  7. Pool boiling heat transfer of deionized and degassed water in packed-perforated copper beads

    Science.gov (United States)

    Wen, Mao-Yu; Jang, Kuang-Jang; Ho, Ching-Yen

    2016-11-01

    Nucleate pool boiling with porous media made of perforated copper beads as the enhanced structure is conducted in saturated, deionized and degassed water. Data are taken at an atmospheric pressure (saturation temperature of 100 °C) and at heat fluxes from 4500 to 72,300 W/m2 while increasing the heat flux. The bead-packed structure is heated on the bottom. The layer of loose particles on the heated surface is free to move under the action of bulk liquid convection and vapor nucleation. The effects of the weight (number), size and layers of the free particles are experimentally explored using copper particles for different copper bead diameters which were 2, 3, 4 and 5 mm. The boiling enhancement is closely related to the particle weight, size and layers, and the heat flux applied. The results show that free particles are presented to have a distinct advantage in boiling heat transfer, resulting in an average increase in the heat transfer coefficient of 126 % relative to the flat plate without particles. In order to obtain insight into the fluid boiling phenomena, flow visualization is also made to observe the detailed fluid boiling characteristics of the copper particles present. The visualizations show that bubble nucleation preferentially occurs at the narrow corner cavities formed between the free particles and the heated surface.

  8. Numerical investigation of Al2O3/water nanofluid laminar convective heat transfer through triangular ducts.

    Science.gov (United States)

    Zeinali Heris, Saeed; Noie, Seyyed Hossein; Talaii, Elham; Sargolzaei, Javad

    2011-02-28

    In this article, laminar flow-forced convective heat transfer of Al2O3/water nanofluid in a triangular duct under constant wall temperature condition is investigated numerically. In this investigation, the effects of parameters, such as nanoparticles diameter, concentration, and Reynolds number on the enhancement of nanofluids heat transfer is studied. Besides, the comparison between nanofluid and pure fluid heat transfer is achieved in this article. Sometimes, because of pressure drop limitations, the need for non-circular ducts arises in many heat transfer applications. The low heat transfer rate of non-circular ducts is one the limitations of these systems, and utilization of nanofluid instead of pure fluid because of its potential to increase heat transfer of system can compensate this problem. In this article, for considering the presence of nanoparticl: es, the dispersion model is used. Numerical results represent an enhancement of heat transfer of fluid associated with changing to the suspension of nanometer-sized particles in the triangular duct. The results of the present model indicate that the nanofluid Nusselt number increases with increasing concentration of nanoparticles and decreasing diameter. Also, the enhancement of the fluid heat transfer becomes better at high Re in laminar flow with the addition of nanoparticles.

  9. Solvation thermodynamics and heat capacity of polar and charged solutes in water.

    Science.gov (United States)

    Sedlmeier, Felix; Netz, Roland R

    2013-03-21

    The solvation thermodynamics and in particular the solvation heat capacity of polar and charged solutes in water is studied using atomistic molecular dynamics simulations. As ionic solutes we consider a F(-) and a Na(+) ion, as an example for a polar molecule with vanishing net charge we take a SPC/E water molecule. The partial charges of all three solutes are varied in a wide range by a scaling factor. Using a recently introduced method for the accurate determination of the solvation free energy of polar solutes, we determine the free energy, entropy, enthalpy, and heat capacity of the three different solutes as a function of temperature and partial solute charge. We find that the sum of the solvation heat capacities of the Na(+) and F(-) ions is negative, in agreement with experimental observations, but our results uncover a pronounced difference in the heat capacity between positively and negatively charged groups. While the solvation heat capacity ΔC(p) stays positive and even increases slightly upon charging the Na(+) ion, it decreases upon charging the F(-) ion and becomes negative beyond an ion charge of q = -0.3e. On the other hand, the heat capacity of the overall charge-neutral polar solute derived from a SPC/E water molecule is positive for all charge scaling factors considered by us. This means that the heat capacity of a wide class of polar solutes with vanishing net charge is positive. The common ascription of negative heat capacities to polar chemical groups might arise from the neglect of non-additive interaction effects between polar and apolar groups. The reason behind this non-additivity is suggested to be related to the second solvation shell that significantly affects the solvation thermodynamics and due to its large spatial extent induces quite long-ranged interactions between solvated molecular parts and groups.

  10. Measure Guideline: Heat Pump Water Heaters in New and Existing Homes

    Energy Technology Data Exchange (ETDEWEB)

    Shapiro, C.; Puttagunta, S.; Owens, D.

    2012-02-01

    This Building America Measure Guideline is intended for builders, contractors, homeowners, and policy-makers. This document is intended to explore the issues surrounding heat pump water heaters (HPWHs) to ensure that homeowners and contractors have the tools needed to appropriately and efficiently install HPWHs. Heat pump water heaters (HPWHs) promise to significantly reduce energy consumption for domestic hot water (DHW) over standard electric resistance water heaters (ERWHs). While ERWHs perform with energy factors (EFs) around 0.9, new HPWHs boast EFs upwards of 2.0. High energy factors in HPWHs are achieved by combining a vapor compression system, which extracts heat from the surrounding air at high efficiencies, with electric resistance element(s), which are better suited to meet large hot water demands. Swapping ERWHs with HPWHs could result in roughly 50% reduction in water heating energy consumption for 35.6% of all U.S. households. This Building America Measure Guideline is intended for builders, contractors, homeowners, and policy-makers. While HPWHs promise to significantly reduce energy use for DHW, proper installation, selection, and maintenance of HPWHs is required to ensure high operating efficiency and reliability. This document is intended to explore the issues surrounding HPWHs to ensure that homeowners and contractors have the tools needed to appropriately and efficiently install HPWHs. Section 1 of this guideline provides a brief description of HPWHs and their operation. Section 2 highlights the cost and energy savings of HPWHs as well as the variables that affect HPWH performance, reliability, and efficiency. Section 3 gives guidelines for proper installation and maintenance of HPWHs, selection criteria for locating HPWHs, and highlights of important differences between ERWH and HPWH installations. Throughout this document, CARB has included results from the evaluation of 14 heat pump water heaters (including three recently released HPWH

  11. Observations of elevated Atlantic water heat fluxes at the boundary of the Arctic Basin.

    Science.gov (United States)

    Lincoln, Benjamin; Rippeth, Tom; Lenn, Yueng; Bacon, Sheldon

    2014-05-01

    The well documented decline in Arctic Sea Ice cover over the past 30 years has outpaced global models as warming in Polar Regions occurs faster than the global mean. The thermohaline circulation brings warm water from the Atlantic Ocean into the Arctic basin. This Atlantic water circulates at depth and contains sufficient heat to melt the sea ice cover several times over. Recent studies have shown that this Atlantic water has warmed and shoaled over recent decades (Polyakov et al, 2010). The stability of the upper Arctic Ocean has also changed, with stratification reduced in the Eurasian basin but increased in the Canada basin. Along with an increased availability of heat the reduction in sea ice cover allows greater potential for wind to input energy to the ocean to vertically mix heat to the surface and further melt sea ice. Direct measurements of vertical mixing rates across the Arctic are essential to understanding the changes in this supply of heat from below, but are scarce due to the challenges of making such measurements in the harsh Arctic environment. We present measurements of turbulent kinetic energy dissipation (ɛ) within the top 500 m of the water column using microstructure measurements made both in open water and under ice during 4 different years. Mean rates of dissipation in the Atlantic water thermocline are calculated and compared for data collected in the European, Siberian and Canadian Arctic, including measurements from 2007 and 2012 when record minimum sea ice extents were recorded. Diapycnal heat fluxes from the mean Atlantic water dissipation rates were calculated from these mean dissipation rates and show significant variation across the Arctic Basin. Profiles in the deep basin generally revealed very low rates of dissipation were low ɛJournal of Physical Oceanography (2010)

  12. Building America Case Study: Solar Water Heating in Multifamily Buildings, Greenfield, Massachusetts

    Energy Technology Data Exchange (ETDEWEB)

    2016-05-01

    Solar domestic hot water (SDHW) systems have been installed on buildings for decades, but because of relatively high costs they have not achieved significant market penetration in most of the country. As more buildings move towards zero net energy consumption, however, many designers and developers are looking more closely at SDHW. In multifamily buildings especially, SDHW may be more practical for several reasons: (1) When designing for zero net energy consumption, solar water heating may be part of the lowest cost approach to meet water heating loads. (2) Because of better scale, SDHW systems in multifamily buildings cost significantly less per dwelling than in single-family homes. (3) Many low-load buildings are moving away from fossil fuels entirely. SDHW savings are substantially greater when displacing electric resistance water heating. (4) In addition to federal tax incentives, some states have substantial financial incentives that dramatically reduce the costs (or increase the benefits) of SDHW systems in multifamily buildings. With support from the U.S. DOE Building America program, the Consortium for Advanced Residential Buildings (CARB) worked with a developer in western Massachusetts to evaluate a SDHW system on a 12-unit apartment building. Olive Street Development completed construction in spring of 2014, and CARB has been monitoring performance of the water heating systems since May 2014.

  13. Design, construction and evaluation of a system of forced solar water heating.

    Science.gov (United States)

    Hernández, E.; Bautista, G. A.; Ortiz, I. L.

    2016-07-01

    The main purpose of this project was to design, construct and evaluate a system of forced solar water heating for domestic consumption, at the Universidad Pontificia Bolivariana-Bucaramanga, Colombia; using solar energy. This is a totally system independent of the electrical grid and an important characteristic is the heating water doesn't mix with the consumption water. The system receives the solar radiation through a flat-plate collector, which it transmits the heat to the water that it flow with impulse from the centrifugal pump of 12VDC, the water circulates toward helical serpentine it is inside of the tank of the storage whose capacity is 100 liters of water. The temperature of the tank is regulated with a controller in such a way that de-energized the pump when it gets the temperature required. The performance thermal or efficiency of the system was evaluated like a relationship between the delivered energy to the water in storage tank and the incident energy in the flat-plate collector.

  14. Analysis of a Hybrid PV/Thermal Solar-Assisted Heat Pump System for Sports Center Water Heating Application

    Directory of Open Access Journals (Sweden)

    Y. Bai

    2012-01-01

    Full Text Available The application of solar energy provides an alternative way to replace the primary source of energy, especially for large-scale installations. Heat pump technology is also an effective means to reduce the consumption of fossil fuels. This paper presents a practical case study of combined hybrid PV/T solar assisted heat pump (SAHP system for sports center hot water production. The initial design procedure was first presented. The entire system was then modeled with the TRNSYS 16 computation environment and the energy performance was evaluated based on year round simulation results. The results show that the system COP can reach 4.1 under the subtropical climate of Hong Kong, and as compared to the conventional heating system, a high fractional factor of energy saving at 67% can be obtained. The energy performances of the same system under different climatic conditions, that include three other cities in France, were analyzed and compared. Economic implications were also considered in this study.

  15. High Efficiency Water Heating Technology Development Final Report. Part I, Lab/Field Performance Evaluation and Accelerated Life Testing of a Hybrid Electric Heat Pump Water Heater (HPWH)

    Energy Technology Data Exchange (ETDEWEB)

    Baxter, Van D. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Murphy, Richard W. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Rice, C. Keith [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Linkous, Randall Lee [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2016-04-01

    DOE has supported efforts for many years with the objective of getting a water heater that uses heat pump technology (aka a heat pump water heater or HPWH) successfully on the residential equipment market. The most recent previous effort (1999-2002) produced a product that performed very well in ORNL-led accelerated durability and field tests. The commercial partner for this effort, Enviromaster International (EMI), introduced the product to the market under the trade name Watter$aver in 2002 but ceased production in 2005 due to low sales. A combination of high sales price and lack of any significant infrastructure for service after the sale were the principal reasons for the failure of this effort. What was needed for market success was a commercial partner with the manufacturing and market distribution capability necessary to allow economies of scale to lead to a viable unit price together with a strong customer service infrastructure. General Electric certainly meets these requirements, and knowing of ORNL s expertise in this area, approached ORNL with the proposal to partner in a CRADA to produce a high efficiency electric water heater. A CRADA with GE was initiated early in Fiscal Year, 2008. GE initially named its product the Hybrid Electric Water Heater (HEWH).

  16. Mass- and heat transfer at water trickled finned tubes. Waerme- und Stoffaustausch an wasserberieselten Rippenrohren

    Energy Technology Data Exchange (ETDEWEB)

    Vilser, L.

    1982-11-22

    At five finned tubes of different geometries measurements were made of the heat and mass transfer during spraying with water and simultaneous passing of an air stream. Mass flow, air temperature, air moisture and air velocity were varied. From the results of the measurements the overall heat flux, the heat flux removed by the spray film, the heat flux transfered to the air by convection, the amount of evaporated water, the heat transfer coefficient between tube wall and spray film, the heat transfer coefficient between spray film and air stream, the mass transfer coefficient and the pressure drop in the air stream were calculated. The results are presented in diagrams, the heat transfer coefficient between spray film and air and the mass transfer coefficient are described by formulae. The comparison of the heat flux densities at the five different tubes shows that for the combination of dry cooling and spraying of the finned tubes, tubes with a small inner tube diameter and small height of the fins are most suited. The assumption frequently made, that the heat transfer coefficient between a gas flow and a spray film may be described by the mathematical interrelationships valid for the gas flow at a stationary wall is true only to a very limited extent. The same is valid for the determination of the pressure loss at the gas side. With a theoretical model it was tried to evaluate the phenomena at the finned tube by means of calculation. Starting from an overall concept described in the introduction formulations for solutions of partial problems were elaborated and results are presented. Because of the necessary simplifications a correlation with the results of the measurements was only achieved in subdomains. Possible starting points for improving the mathematical model are qualitatively described.

  17. The Utilisation of Solar System in Combined Heating System of Water

    Directory of Open Access Journals (Sweden)

    Ján Jobbágy

    2017-01-01

    Full Text Available The paper assessed the topicality and returns of solar system utilization to heating of water. Practical measurements were conducted after reconstruction of the family house. (in Nesvady, Slovak republic, on which the solar system were assembled. The system consists of the gas heater, solar panels, distributions and circulation pump. The solar system was assembled due to decreasing of operation costs and connected with conventional already used gas heating system by boiler Quantum (V = 115 L. The conventional system was used for 21 days to gather basic values for evaluation. At this point it was observed that 11.93 m3 of gas is needed to heat up 1 m3 of water. Used water in this case was heated from initial 16.14 °C to 52.04 °C of output temperature. Stand by regime of boiler was characterized by 0.012 m3.h-1 consumption of gas. The rest of the measurements represent the annual (from 03/2013 to 02/2014 operation process of boiler Tatramat VTS 200L (trivalent with 200 litres of volume (as a part of Thermosolar solar system. The solar collectors TS 300 are also part of the solar system. An input and output temperatures of heating water we observed along with water and gas consumption, intensity of solar radiation and actual weather conditions. The amount of heat produced by solar system was then calculated. Total investment on solar system were 2,187.7 € (1,475.7 € with subsidy. Therefore, return on investment for the construction of the solar system was set at 23 years even with subsidy.

  18. Water, heat fluxes and water use efficiency measurement and modeling above a farmland in the North China Plain

    Institute of Scientific and Technical Information of China (English)

    QIN Zhong; YU Qiang; XU Shouhua; HU Bingmin; SUN Xiaomin; LIU Enmin; WANG Jishun; YU Guirui; ZHU Zhilin

    2005-01-01

    Net radiation (Rn), water vapor flux (LE), sensible heat flux (Hs) and soil heat flux (G)were measured above a summer maize field with the eddy-covariance technique, simulation and analysis of water, heat fluxes and crop water use efficiency were made with the RZ-SHAW model at the same time in this study. The results revealed significant diurnal and seasonal variability of water vapor flux for summer maize. Most part of Rn was consumed by the evapotranspiration of the summer maize. The proportion of water vapor flux to net radiation ((LE/Rn) increased with the crop development and peaked around milk-filling stage with a value of 60%, a slightly lower than that obtained by the RZ-SHAW model. Daily evapotranspiration estimated by the model agreed with the results measured with the eddy-covariance technique, indices of agreement (IA) for hourly water vapor fluxes simulated and measured were above 0.75, root mean square errors (RMSE) were no more than 1.0. Diurnal patterns of Hs showed the shape of inverted "U" shifted to the forenoon with a maximum value around 11:30 (Beijing time), while LE exhibited an inverted "V" with a maximum value at around 13:00, about an hour later than Hs. Diurnal change of CO2showed an asymmetrical "V" curve and its maximal rates occurred at about 11:30. Variations of water use efficiency during the phonological stages of the summer maize showed a rapid increase with the photosynthetic photon flux density (PPFD) after sunrise, a state of equilibrium around 10:00 followed a decrease. Maximum values of water use efficiency were 24.3, and its average value ranged from 7.6 to 10.3 g kg-1.

  19. Thickness effects of water overlayer on its explosive evaporation at heated metal surfaces

    Energy Technology Data Exchange (ETDEWEB)

    Dou Yusheng E-mail: ysd@chem.psu.edu; Zhigilei, Leonid V.; Postawa, Zbigniew; Winograd, Nicholas; Garrison, Barbara J

    2001-06-01

    Molecular dynamics (MD) simulations have been employed to investigate the effect of the thickness of a water overlayer on the character of its ejection from a heated Au surface. The simulations are performed for five systems differing in the thickness of the water overlayer which was adsorbed on a metal substrate heated to 1000 K. For each system, an explosive evaporation occurs in the part of the water film adjacent to the metal surface and the upper part of the film is pushed off by the generated force. The average maximum temperature of the water film decreases as the film thickness increases. In contrast, the temperature achieved by the fast cooling due to the explosive evaporation shows an inverse trend. The significance of these model calculations to matrix-assisted laser desorption and ionization (MALDI) mass spectrometry is discussed.

  20. Performance Analysis and Application of Three Different Computational Methods for Solar Heating System with Seasonal Water Tank Heat Storage

    Directory of Open Access Journals (Sweden)

    Dongliang Sun

    2013-01-01

    Full Text Available We analyze and compare three different computational methods for a solar heating system with seasonal water tank heat storage (SHS-SWTHS. These methods are accurate numerical method, temperature stratification method, and uniform temperature method. The accurate numerical method can accurately predict the performance of the system, but it takes about 4 to 5 weeks, which is too long and hard for the performance analysis of this system. The temperature stratification method obtains relatively accurate computation results and takes a relatively short computation time, which is about 2 to 3 hours. Therefore, this method is most suitable for the performance analysis of this system. The deviation of the computational results of the uniform temperature method is great, and the time consumed is similar to that of the temperature stratification method. Therefore, this method is not recommended herein. Based on the above analyses, the temperature stratification method is applied to analyze the influence of the embedded depth of water tank, the thickness of thermal insulation material, and the collection area on the performance of this system. The results will provide a design basis for the related demonstration projects.

  1. Improved Design Tools for Surface Water and Standing Column Well Heat Pump Systems (DE-EE0002961)

    Energy Technology Data Exchange (ETDEWEB)

    Spitler, J. D.; Culling, J. R.; Conjeevaram, K.; Ramesh, M.; Selvakumar, M.

    2012-11-30

    Ground-source heat pump (GSHP) systems are perhaps the most widely used “sustainable” heating and cooling systems, with an estimated 1.7 million installed units with total installed heating capacity on the order of 18 GW. They are widely used in residential, commercial, and institutional buildings. Standing column wells (SCW) are one form of ground heat exchanger that, under the right geological conditions, can provide excellent energy efficiency at a relatively low capital cost. Closed-loop surface water heat pump (SWHP) systems utilize surface water heat exchangers (SWHE) to reject or extract heat from nearby surface water bodies. For building near surface water bodies, these systems also offer a high degree of energy efficiency at a low capital cost. However, there have been few design tools available for properly sizing standing column wells or surface water heat exchangers. Nor have tools for analyzing the energy consumption and supporting economics-based design decisions been available. The main contributions of this project lie in providing new tools that support design and energy analysis. These include a design tool for sizing surface water heat exchangers, a design tool for sizing standing column wells, a new model of surface water heat pump systems implemented in EnergyPlus and a new model of standing column wells implemented in EnergyPlus. These tools will better help engineers design these systems and determine the economic and technical feasibility.

  2. Detailed near-infrared study of the `water'-related transformations in silcrete upon heat treatment

    Science.gov (United States)

    Schmidt, Patrick; Lauer, Christoph; Buck, Gerald; Miller, Christopher E.; Nickel, Klaus G.

    2017-01-01

    In archaeology, lithic heat treatment is the process of modifying a rock for stone tool production using fire. Although the earliest known cases of heat treatment come from South Africa and involved silcrete, a microcrystalline pedogenic silica rock, its thermal transformations remain poorly understood. We investigate the `water'-related transformations in silcrete using direct transmission near-infrared spectroscopy. We found that SiOH is noticeably lost between 250 and 450 °C and hydroxyl reacts with H2O, part of which is trapped in the structure of the rocks. This water can only be evaporated through heat-induced fracturing at high temperatures, imposing maximum temperatures for silcrete heat treatment of approximately 500 °C. Between 250 and 450 °C new siloxane bonds are formed according to the reaction 2SiOH → Si-O-Si + H2O, which can be expected to transform the rock's mechanical properties. The tolerance of silcrete for relatively fast ramp rates can be explained by its pore volume and low SiOH content, ensuring good water evaporation. These results shed light on the processes taking place in silcrete during heat treatment and allow for a better understanding of the parameters needed for it.

  3. Estimation of sensible heat, water vapor, and CO2 fluxes using the flux-variance method.

    Science.gov (United States)

    Hsieh, Cheng-I; Lai, Mei-Chun; Hsia, Yue-Joe; Chang, Tsang-Jung

    2008-07-01

    This study investigated the flux-variance relationships of temperature, humidity, and CO(2), and examined the performance of using this method for predicting sensible heat (H), water vapor (LE), and CO(2) fluxes (F(CO2)) with eddy-covariance measured flux data at three different ecosystems: grassland, paddy rice field, and forest. The H and LE estimations were found to be in good agreement with the measurements over the three fields. The prediction accuracy of LE could be improved by around 15% if the predictions were obtained by the flux-variance method in conjunction with measured sensible heat fluxes. Moreover, the paddy rice field was found to be a special case where water vapor follows flux-variance relation better than heat does. However, the CO(2) flux predictions were found to vary from poor to fair among the three sites. This is attributed to the complicated CO(2) sources and sinks distribution. Our results also showed that heat and water vapor were transported with the same efficiency above the grassland and rice paddy. For the forest, heat was transported 20% more efficiently than evapotranspiration.

  4. Secondary exploitation of water and heat; Zweitverwertung von Wasser und Waerme

    Energy Technology Data Exchange (ETDEWEB)

    Moschke, Franziska [Hansgrohe AG, Schiltach (Germany)

    2010-07-15

    In the dormitory Oikos (Freiburg, Federal Republic of Germany) the experts of the company Pontos GmbH (Offenburg, Federal Republic of Germany) have tested the combination of a proven technology for grey water recycling with a technology for heat recovery. Apart from a sustainable handling of the resource water, the research project which is promoted by the southern Baden energy supplier Badenova AG also realises significant savings in energy and CO{sub 2}.

  5. The evaluation of steam-water heat transfer in vertical channel using Trac code

    Energy Technology Data Exchange (ETDEWEB)

    Sang Won, Lee; Han Gon, Kim; Byong Sup, Kim; Seung, Jong [Korea Electric Power Co., Taejon (Korea, Republic of)

    2001-07-01

    The safety injection system(SIS) of the Korean Next Generation Reactor (KNGR) injects water into the reactor vessel directly for the effective usage of ECC water. The injection location is 83 inches higher than cold leg centerline. Due to this geometrical characteristics, during late reflood phase in large break LOCA, complicate thermal-hydraulic phenomena different from existing cold-leg injection plant could be occurred. Among these phenomena, the steam-water heat transfer is evaluated in this paper. We have selected TRAC code for the evaluation tool because it can handle the reactor vessel in three-dimensional coordinates and is has been validated using UPTF experiments. For this evaluation, we performed steam-water interaction experiments in vertical rectangular channel. The experiments have been performed for co-current and counter-current flow, various steam velocity, various water flow rate. Water is injected from the top of the channel as a thin film. Steam is injected from the top or the bottom of channel. All the experiments are performed in the condition of atmospheric pressure and that void fraction is ranged from 0.9 to 0.95. Therefore, it can be treated as annular-mist flow regime. TRAC model has been developed for the simulation of these experiments. As a result of simulation, it can be concluded that TRAC code predicts heat transfer coefficients as much as 10 times compared to experimental results. In order to correct these differences, we modified the heat transfer correlation for annular-mist flow in TRAC code. This modified correlation can be used heat transfer in the downcomer only. We will perform the larger break LOCA sensitivity analyses for the effect of heat transfer in the downcomer. (authors)

  6. Experimental study of laminar forced convective heat transfer of deionized water based copper (I) oxide nanofluids in a tube with constant wall heat flux

    Science.gov (United States)

    Umer, Asim; Naveed, Shahid; Ramzan, Naveed

    2016-10-01

    Nanofluids, having 1-100 nm size particles in any base fluid are promising fluid for heat transfer intensification due to their enhanced thermal conductivity as compared with the base fluid. The forced convection of nanofluids is the major practical application in heat transfer equipments. In this study, heat transfer enhancements at constant wall heat flux under laminar flow conditions were investigated. Nanofluids of different volume fractions (1, 2 and 4 %) of copper (I) oxide nanoparticles in deionized water were prepared using two step technique under mechanical mixing and ultrasonication. The results were investigated by increasing the Reynolds number of the nanofluids at constant heat flux. The trends of Nusselt number variation with dimensionless length (X/D) and Reynolds numbers were studied. It was observed that heat transfer coefficient increases with increases particles volume concentration and Reynolds number. The maximum enhancement in heat transfer coefficient of 61 % was observed with 4 % particle volume concentration at Reynolds number (Re ~ 605).

  7. A Direct Heat Exchanger Unit used for Domestic Hot Water Supply in a Single-family House Supplied by Low Energy District Heating

    DEFF Research Database (Denmark)

    Brand, Marek; Thorsen, Jan Eric; Svendsen, Svend

    2010-01-01

    on the testing of the dynamic behaviour of an Instantaneous Heat Exchanger Unit(IHEU) designed for DHW heating and space heating in detached family houses supplied by LEDH ensuring an entry-to-substation temperature of 51 °C. We measured the time it takes for the IHEU to produce DHW with a temperature of 42 °C......The increasing number of new and renovated buildings with reduced heating requirements will soon make traditional District Heating (DH) systems uneconomic. To keep DH competitive in the future, the heat loss in DH networks needs to be reduced. One option is to reduce the supply temperature of DH...... as much as possible. This requires a review of the behaviour of the whole domestic hot water (DHW) supply system with focus on the user comfort and overall costs. This paper describes some practical approaches to the implementation of this Low Energy District Heating (LEDH) concept. It reports...

  8. Solar heating and hot water system installed at Municipal Building complex, Abbeville, South Carolina

    Science.gov (United States)

    1979-01-01

    Information on the solar energy system installed at the new municipal building for the City of Abbeville, SC is presented, including a description of solar energy system and buildings, lessons learned, and recommendations. The solar space heating system is a direct air heating system. The flat roof collector panel was sized to provide 75% of the heating requirement based on an average day in January. The collectors used are job-built with two layers of filon corrugated fiberglass FRP panels cross lapped make up the cover. The storage consists of a pit filled with washed 3/4 in - 1 1/2 in diameter crushed granite stone. The air handler includes the air handling mechanism, motorized dampers, air circulating blower, sensors, control relays and mode control unit. Solar heating of water is provided only those times when the hot air in the collector is exhausted to the outside.

  9. Dynamic modeling of thermal conditions for hot-water district-heating net- works

    Institute of Scientific and Technical Information of China (English)

    ZHOU Shou-jun; TIAN Mao-cheng; ZHAO You-en; GUO Min

    2014-01-01

    To investigate the dynamic characteristics of the thermal conditions of hot-water district-heating networks, a dynamic modeling method is proposed with consideration of the heat dissipations in pipes and the characteristic line method is adopted to solve it. Besides, the influences of different errors, space steps and initial values on the convergence of the dynamic model results are analyzed for a model network. Finally, a part of a certain city district-heating system is simulated and the results are compared with the actual operation data in half an hour from 6 secondary heat stations. The results indicate that the relative errors for the supply pressure and temperature in 5 stations are all within 2%, except in one station, where the relative error approaches 4%. So the proposed model and algorithm are validated.

  10. Effect of the Heat Flux Density on the Evaporation Rate of a Distilled Water Drop

    Directory of Open Access Journals (Sweden)

    Ponomarev Konstantin

    2016-01-01

    Full Text Available This paper presents the experimental dependence of the evaporation rate of a nondeaerated distilled water drop from the heat flux density on the surfaces of non-ferrous metals (copper and brass. A drop was placed on a heated substrate by electronic dosing device. To obtain drop profile we use a shadow optical system; drop symmetry was controlled by a high-speed video camera. It was found that the evaporation rate of a drop on a copper substrate is greater than on a brass. The evaporation rate increases intensively with raising volume of a drop. Calculated values of the heat flux density and the corresponding evaporation rates are presented in this work. The evaporation rate is found to increase intensively on the brass substrate with raising the heat flux density.

  11. Thermal stratification in a hot water tank established by heat loss from the tank

    DEFF Research Database (Denmark)

    Fan, Jianhua; Furbo, Simon

    2012-01-01

    This paper presents numerical investigations of thermal stratification in a vertical cylindrical hot water tank established by standby heat loss from the tank. The transient fluid flow and heat transfer in the tank during cooling caused by standby heat loss are calculated by means of validated...... computational fluid dynamics (CFD) models. The measured heat loss coefficient for the different parts of the tank is used as input to the CFD model. Parametric studies are carried out using the validated models to investigate the influence on thermal stratification of the tank by the downward flow...... and the corresponding upward flow in the central parts of the tank. Tank design parameters such as tank volume, height to diameter ratio and insulation and different initial conditions of the tank are investigated.It is elucidated how thermal stratification in the tank is influenced by the natural convection and how...

  12. Analysis of air-to-water heat pump in cold climate: comparison between experiment and simulation

    Directory of Open Access Journals (Sweden)

    Karolis Januševičius

    2015-10-01

    Full Text Available Heat pump systems are promising technologies for current and future buildings and this research presents the performance of air source heat pump (ASHP system. The system was monitored, analysed and simulated using TRNSYS software. The experimental data were used to calibrate the simulation model of ASHP. The specific climate conditions are evaluated in the model. It was noticed for the heating mode that the coefficient of performance (COP varied from 1.98 to 3.05 as the outdoor temperature changed from –7.0 ºC to +5.0 ºC, respectively. TRNSYS simulations were also performed to predict seasonal performance factor of the ASHP for Vilnius city. It was identified that seasonal performance prediction could be approximately 15% lower if frost formation effects are not included to air-water heat pump simulation model.

  13. Comparison of Heat and Bromide as Ground Water Tracers Near Streams

    Science.gov (United States)

    Constantz, J.; Cox, M.H.; Su, G.W.

    2003-01-01

    Heat and bromide were compared as tracers for examining stream/ground water exchanges along the middle reaches of the Santa Clara River, California, during a 10-hour surface water sodium bromide injection test. Three cross sections that comprise six shallow (sodium bromide injection test. Vertical, one-dimensional simulations of bromide concentrations in the sediments yielded a good match to the observed bromide concentrations, without adjustment of any model parameters except solute dispersivities. This indicates that, for the spatial and temporal scales examined on the Santa Clara River, the use of heat and bromide as tracers provide comparable information with respect to apparent hydraulic conductivities and fluxes for sediments near streams. In other settings, caution should be used due to differences in the nature of conservative (bromide) versus nonconservative (heat) tracers, particularly when preferential flowpaths are present.

  14. Remediation of NAPL below the water table by steam-induced heat conduction

    Science.gov (United States)

    Gudbjerg, J.; Sonnenborg, T. O.; Jensen, K. H.

    2004-08-01

    Previous experimental studies have shown that NAPL will be removed when it is contacted by steam. However, in full-scale operations, steam may not contact the NAPL directly and this is the situation addressed in this study. A two-dimensional intermediate scale sand box experiment was performed where an organic contaminant was emplaced below the water table at the interface between a coarse and a fine sand layer. Steam was injected above the water table and after an initial heating period the contaminant was recovered at the outlet. The experiment was successfully modeled using the numerical code T2VOC and the dominant removal mechanism was identified to be heat conduction induced boiling of the separate phase contaminant. Subsequent numerical modeling showed that this mechanism was insensitive to the porous medium properties and that it could be evaluated by considering only one-dimensional heat conduction.

  15. Turbulent heat and mass transfers across a thermally stratified air-water interface

    Science.gov (United States)

    Papadimitrakis, Y. A.; Hsu, Y.-H. L.; Wu, J.

    1986-01-01

    Rates of heat and mass transfer across an air-water interface were measured in a wind-wave research facility, under various wind and thermal stability conditions (unless otherwise noted, mass refers to water vapor). Heat fluxes were obtained from both the eddy correlation and the profile method, under unstable, neutral, and stable conditions. Mass fluxes were obtained only under unstable stratification from the profile and global method. Under unstable conditions the turbulent Prandtl and Schmidt numbers remain fairly constant and equal to 0.74, whereas the rate of mass transfer varies linearly with bulk Richardson number. Under stable conditions the turbulent Prandtl number rises steadily to a value of 1.4 for a bulk Richardson number of about 0.016. Results of heat and mass transfer, expressed in the form of bulk aerodynamic coefficients with friction velocity as a parameter, are also compared with field data.

  16. Review and proposal for heat transfer predictions at supercritical water conditions using existing correlations and experiments

    Energy Technology Data Exchange (ETDEWEB)

    Jaeger, Wadim, E-mail: wadim.jaeger@kit.edu [Karlsruhe Institute of Technology, Institute for Neutron Physics and Reactor Technology, DE-76344 Eggenstein-Leopoldshafen (Germany); Sanchez Espinoza, Victor Hugo [Karlsruhe Institute of Technology, Institute for Neutron Physics and Reactor Technology, DE-76344 Eggenstein-Leopoldshafen (Germany); Hurtado, Antonio [Technical University of Dresden, Institute of Power Engineering, DE-01062 Dresden (Germany)

    2011-06-15

    Highlights: > Implementation of heat transfer correlations for supercritical water into TRACE. > Simulation of several heat transfer experiments with modified TRACE version. > Most correlations are not able to reproduce the experimental results. > Bishop, Sandberg and Tong correlation is most suitable for TRACE applications. - Abstract: This paper summarizes the activities of the TRACE code validation at the Institute for Neutron Physics and Reactor Technology related to supercritical water conditions. In particular, the providing of the thermo physical properties and its appropriate use in the wall-to-fluid heat transfer models in the frame of the TRACE code is the object of this investigation. In a first step, the thermo physical properties of the original TRACE code were modified in order to account for supercritical conditions. In a second step, existing Nusselt correlations were reviewed and implemented into TRACE and available experiments were simulated to identify the most suitable Nusselt correlation(s).

  17. The integration of water loop heat pump and building structural thermal storage systems

    Energy Technology Data Exchange (ETDEWEB)

    Marseille, T.J.; Schliesing, J.S.

    1991-10-01

    Many commercial buildings need heat in one part and, at the same time, cooling in another part. Even more common is the need for heating during one part of the day and cooling during another in the same spaces. If that energy could be shifted or stored for later use, significant energy might be saved. If a building's heating and cooling subsystems could be integrated with the building's structural mass and used to collect, store, and deliver energy, the energy might be save cost-effectively. To explore this opportunity, researchers at the Pacific Northwest Laboratory (PNL) examined the thermal interactions between the heating, ventilating, and air-conditioning (HVAC) system and the structure of a commercial building. Computer models were developed to simulate the interactions in an existing building located in Seattle, Washington, to determine how these building subsystems could be integrated to improve energy efficiency. The HVAC subsystems in the existing building were modeled. These subsystems consist of decentralized water-source heat pumps (WSHP) in a closed water loop, connected to cooling towers for heat rejection during cooling mode and boilers to augment heating. An initial base case'' computer model of the Seattle building, as-built, was developed. Metered data available for the building were used to calibrate this model to ensure that the analysis would provide information that closely reflected the operation of a real building. The HVAC system and building structure were integrated in the model using the concrete floor slabs as thermal storage media. The slabs may be actively charged during off-peak periods with the chilled water in the loop and then either actively or passively discharged into the conditioned space during peak periods. 21 refs., 37 figs., 17 tabs.

  18. Convective heat transfer and flow characteristics of Cu-water nanofluid

    Institute of Scientific and Technical Information of China (English)

    LI; Qiang(李强); XUAN; Yimin(宣益民)

    2002-01-01

    An experimental system is built to investigate convective heat transfer and flow characteristics of the nanofluid in a tube. Both the convective heat transfer coefficient and friction factor of Cu-water nanofluid for the laminar and turbulent flow are measured. The effects of such factors as the volume fraction of suspended nanoparticles and the Reynolds number on the heat transfer and flow characteristics are discussed in detail. The experimental results show that the suspended nanoparticles remarkably increase the convective heat transfer coefficient of the base fluid and show that the friction factor of the sample nanofluid with the low volume fraction of nanoparticles is almost not changed. Compared with the base fluid, for example, the convective heat transfer coefficient is increased about 60% for the nanofluid with 2.0 vol% Cu nanoparticles at the same Reynolds number. Considering the factors affecting the convective heat transfer coefficient of the nano- fluid, a new convective heat transfer correlation for nanofluid under single-phase flows in tubes is established. Comparison between the experimental data and the calculated results indicate that the correlation describes correctly the energy transport of the nanofluid.

  19. Verification test report on a solar heating and hot water system

    Science.gov (United States)

    1978-01-01

    Information is provided on the development, qualification and acceptance verification of commercial solar heating and hot water systems and components. The verification includes the performances, the efficiences and the various methods used, such as similarity, analysis, inspection, test, etc., that are applicable to satisfying the verification requirements.

  20. Solar heating and hot water system installed at Charlotte Memorial Hospital, Charlotte, North Carolina

    Science.gov (United States)

    1981-01-01

    Detailed information regarding the design and installation of a heating and hot water system in a commercial application is given. This information includes descriptions of system and building, design philosophy, control logic operation modes, design and installation drawing and a brief description of problems encountered and their solutions.

  1. Solar heating and domestic hot water system installed at North Dallas High School

    Science.gov (United States)

    1980-01-01

    The solar energy system located at the North Dallas High School, Dallas, Texas is discussed. The system is designed as a retrofit in a three story with basement, concrete frame high school building. Extracts from the site files, specification references for solar modification to existing building heating and domestic hot water systems, drawings, installation, operation and maintenance instructions are included.

  2. Energy and water cycle over the Tibetan plateau : surface energy balance and turbulent heat fluxes

    NARCIS (Netherlands)

    Su, Zhongbo; Zhang, Ting; Ma, Yaoming; Jia, Li; Wen, Jun

    2006-01-01

    This contribution presents an overview and an outlook of studies on energy and water cycle over the Tibetan plateau with focuses on the estimation of energy balance terms and turbulent heat fluxes. On the basis of the surface energy balance calculations, we show that the phenomena of the energy imba

  3. Energy and water cycle over the Tibetan Plateau: surface energy balance and turbulent heat fluxes

    NARCIS (Netherlands)

    Su, Z.; Zhang, T.; Ma, Y.; Jia, L.; Wen, J.

    2006-01-01

    This contribution presents an overview and an outlook of studies on energy and water cycle over the Tibetan plateau with focuses on the estimation of energy balance terms and turbulent heat fluxes. On the basis of the surface energy balance calculations, we show that the phenomena of the energy imba

  4. Measure Guideline. Heat Pump Water Heaters in New and Existing Homes

    Energy Technology Data Exchange (ETDEWEB)

    Shapiro, Carl [Consortium for Advanced Residential Buildings (CARB), Norwalk, CT (United States); Puttagunta, Srikanth [Consortium for Advanced Residential Buildings (CARB), Norwalk, CT (United States); Owens, Douglas [Consortium for Advanced Residential Buildings (CARB), Norwalk, CT (United States)

    2012-02-01

    This Building America Measure Guideline is intended for builders, contractors, homeowners, and policy-makers. This document is intended to explore the issues surrounding heat pump water heaters (HPWHs) to ensure that homeowners and contractors have the tools needed to appropriately and efficiently install HPWHs

  5. Achieving low return temperature for domestic hot water preparation by ultra-low-temperature district heating

    DEFF Research Database (Denmark)

    Yang, Xiaochen; Svendsen, Svend

    2017-01-01

    to achieve high efficiency of the ULTDH system, the return temperature should be as low as possible. For the energy-efficient buildings in the future, it is feasible to use ULTDH to cover the space heating demand. However, considering the comfort and hygiene requirements of domestic hot water (DHW...

  6. Solar Water Heating as a Potential Source for Inland Norway Energy Mix

    Directory of Open Access Journals (Sweden)

    Dejene Assefa Hagos

    2014-01-01

    Full Text Available The aim of this paper is to assess solar potential and investigate the possibility of using solar water heating for residential application in Inland Norway. Solar potential based on observation and satellite-derived data for four typical populous locations has been assessed and used to estimate energy yield using two types of solar collectors for a technoeconomic performance comparison. Based on the results, solar energy use for water heating is competitive and viable even in low solar potential areas. In this study it was shown that a typical tubular collector in Inland Norway could supply 62% of annual water heating energy demand for a single residential household, while glazed flat plates of the same size were able to supply 48%. For a given energy demand in Inland Norway, tubular collectors are preferred to flat plate collectors for performance and cost reasons. This was shown by break-even capital cost for a series of collector specifications. Deployment of solar water heating in all detached dwellings in Inland could have the potential to save 182 GWh of electrical energy, equivalent to a reduction of 15,690 tonnes of oil energy and 48.6 ktCO2 emissions, and contributes greatly to Norway 67.5% renewable share target by 2020.

  7. Migration of bisphenol A into water from polycarbonate baby bottles during microwave heating

    NARCIS (Netherlands)

    Ehlert, K.A.; Beumer, C.W.E.; Groot, M.C.E.

    2008-01-01

    A comprehensive migration database was established for bisphenol A from polycarbonate baby bottles into water during exposure to microwave heating. Eighteen different brands of polycarbonate baby bottles sold in Europe were collected. Initial residual content of bisphenol A and migration after micro

  8. One-dimensional model for heat transfer to a supercritical water flow in a tube

    NARCIS (Netherlands)

    Sallevelt, J.L.H.P.; Withag, J.A.M.; Bramer, E.A.; Brilman, D.W.F.; Brem, G.

    2012-01-01

    Heat transfer in water at supercritical pressures has been investigated numerically using a one-dimensional modeling approach. A 1D plug flow model has been developed in order to make fast predictions of the bulk-fluid temperature in a tubular flow. The chosen geometry is a vertical tube with an inn

  9. Refreshing the role of open water surfaces on mitigating the maximum urban heat island effect

    NARCIS (Netherlands)

    Steeneveld, G.J.; Koopmans, S.; Heusinkveld, B.G.; Theeuwes, N.E.

    2014-01-01

    During warm summer episodes citizens in urban areas are subject to reduced human thermal comfort and negative health effects. To mitigate these adverse effects, land use planners and urban designers have used the evaporative power of water bodies as a tool to limit the urban heat island effect (UHI)

  10. Migration of bisphenol A into water from polycarbonate baby bottles during microwave heating

    NARCIS (Netherlands)

    Ehlert, K.A.; Beumer, C.W.E.; Groot, M.C.E.

    2008-01-01

    A comprehensive migration database was established for bisphenol A from polycarbonate baby bottles into water during exposure to microwave heating. Eighteen different brands of polycarbonate baby bottles sold in Europe were collected. Initial residual content of bisphenol A and migration after

  11. Operation Performance of Central Solar Heating System with Seasonal Storage Water Tank in Harbin

    Institute of Scientific and Technical Information of China (English)

    YE Ling; JIANG Yi-qiang; YAO Yang; ZHANG Shi-cong

    2009-01-01

    This paper presented a preliminary research on the central solar heating system with seasonal stor-age(CSHSSS)used in cold climate in China.A mathematical model of the solar energy seasonal storage water tank used in the central solar heating system was firstly developed based on energy conservation.This was fol-lowed by the simulation of the CSHSSS used in a two-floor villa in Harbin,and analysis of the impacts on storage water temperature of tank volume,solar collector area,tank burial depth,insulation thickness around the tank,etc.The results show there is a relatively economical tank volume to optimize the system efficiency,which de-creases with increasing tank volume at the constant collector area,and increases with increasing collector area at the constant tank volume.Furthermore,the insulation thickness has obvious effect on avoiding heat loss,while the tank burial depth doesn't.In addition-the relationship between the solar collector efficiency and storage wa-ter temperature is also obtained,it decreases quickly with increasing storing water temperature,and then in-creases slowly after starting space heating system.These may be helpful for relevant design and optimization in cold climates in China and all over the world.

  12. Mitigating Climate Change by the Development and Deployment of Solar Water Heating Systems

    Directory of Open Access Journals (Sweden)

    S. T. Wara

    2013-01-01

    Full Text Available Solar energy is becoming an alternative for the limited fossil fuel resources. One of the simplest and most direct applications of this energy is the conversion of solar radiation into heat, which can be used in Water Heating Systems. Ogun State in Nigeria was used as a case study. The solar radiation for the state was explored with an annual average of 4.775 kWh/m2 recorded. The designed system comprised storage tanks and the collector unit which comprises wooden casing, copper tube, and aluminium foil. Test results for the unlagged and lagged storage tanks for water temperature at various angles of inclination (2.500°–20.000° were on the average 27.800°C and 28.300°C, respectively, for the inlet temperature and 60.100°C and 63.000°C for the outlet temperature, respectively. The efficiency of the Solar Water Heating System was 72.500% and the power saved 2.798 kW. The cost of the unit is put at 1121,400 ($145 as at August 2012. The unit developed can be applied for the purpose of reducing the cost of energy, dealing with environmental challenges, and improving the use of energy, hence serving as a climate mitigation process as this can be extended for water heating for domestic and other industrial purposes.

  13. Ground-water temperature of the Wyoming quadrangle in central Delaware : with application to ground-water-source heat pumps

    Science.gov (United States)

    Hodges, Arthur L.

    1982-01-01

    Ground-water temperature was measured during a one-year period (1980-81) in 20 wells in the Wyoming Quadrangle in central Delaware. Data from thermistors set at fixed depths in two wells were collected twice each week, and vertical temperature profiles of the remaining 18 wells were made monthly. Ground-water temperature at 8 feet below land surface in well Jc55-1 ranged from 45.0 degrees F in February to 70.1 degrees F in September. Temperature at 35 feet below land surface in the same well reached a minimum of 56.0 degrees F in August, and a maximum of 57.8 degrees F in February. Average annual temperature of ground water at 25 feet below land surface in all wells ranged from 54.6 degrees F to 57.8 degrees F. Variations of average temperature probably reflect the presence or absence of forestation in the recharge areas of the wells. Ground-water-source heat pumps supplied with water from wells 30 or more feet below land surface will operate more efficiently in both heating and cooling modes than those supplied with water from shallower depths. (USGS)

  14. Thermal inactivation of Bacillus anthracis Sterne in irradiated ground beef heated in a water bath or cooked on commercial grills

    Science.gov (United States)

    The thermal stability of heat-shocked and non heat-shocked spores of the virulence-attenuated Sterne strain of Bacillus anthracis was evaluated at select temperatures in irradiated, raw ground beef (25% fat) heated in a water bath or cooked using two different commercial grills. For the former, 3-g ...

  15. Beneficial use of waste heat in municipal water supply. Technical report TR-79-3

    Energy Technology Data Exchange (ETDEWEB)

    Porter, R.W.

    1979-08-01

    The relatively low temperature of thermal discharges from steam-electric power plants makes waste-heat utilization difficult without modification of the power cycle and attendant reduction in electrical energy generated. In situ beneficial use of waste heat by direct once-through condenser discharge into a municipal water supply is discussed. Computations are presented regarding the matching of flow rates, heat losses in distribution and energy savings. A number of benefits and penalties are also assessed qualitatively including legal and operational aspects and reliability. Especially attractive are improvements in electrical generating efficiency, and savings in water-heater energy. Secondary advantages include alleviation of pipe freeze up in winter and improved efficiency of slightly heated waste-water treatment. Penalties include additional pumping power for distribution in the water supply due to increased back pressure on the steam turbines which employ condensers cooled by the water they pump. Additional chlorine is also required to maintain a residual concentration in the distribution system. There may also be difficulties with public acceptance of water preheated by up to about 24/sup 0/F, especially in summer. The water supply of greater Chicago and 4880 MW(e) of colocated fossil-fired load-following generating capacity were analyzed as a hypothetical test case. It was concluded that the net annual energy savings is 23 x 10/sup 12/B, equivalent to 4 million bbl of oil, with a net savings in cost of $12./capita for the population of 4.66 m. While not developed for energy conservation purposes, three actual systems with operating experience are summarized. In order to determine feasibility of application, site-specific systems analysis is required.

  16. A coupled model of soil water-heat-solute movement under the mulched drip irrigation condition

    Science.gov (United States)

    Hu, H.; Tian, F.; Gao, L.; Hu, H.

    2010-12-01

    : The mulched drip irrigation (MDI), first developed in northwestern part of China (Xinjiang Province) in the cotton field in 1996, can obtain higher yield while at the lower cost of water consumption and thus becomes popular rapidly. However, it has the potential risk of salinizing the arable soil. Also, plastic film can alter the energy balance at the ground surface and invoke the regime shifting of soil heat transfer. It is, therefore, necessary to simulate the inter-related movement of water, heat, and dissolvable solute in the soil under the MDI condition for the purpose of sustainable agricultural production as well as of climate change issue. With the different boundary condition and irrigation rate, the transportation and distribution features of water-heat-salt under the MDI condition are significantly different from those under the other irrigation methods. The existing tools such as HYDRUS and VS2DH(T) could not set up the special boundary condition relevant to MDI, e.g., the moving ponded area. A new two-dimensional numerical model of Richard’s equation and Convection-Dispersion equations was developed which coupled soil water, solute, and heat together. For the homogenous and isotropic porous media, the soil water-heat-solute movement under the MDI condition is considered as 2D problem. The Richards and solute convection-diffusive equations are transformed into ordinary differential equations (ODEs) through spatial semi-discretization, and so do the corresponding boundary conditions. The resultant ODEs are solved using a state-of-the-art solver, CVODE developed at the Lawrence Livermore National Laboratory. The model is validated against the numerical examples as well as the field data. The results show the high numerical efficiency, the high simulation accuracy, and the flexibility of the model to mimic changing boundary conditions. Key words: numerical model, Richard’s equation, Convection-Diffusive equation, CVODE

  17. Stable water isotope and surface heat flux simulation using ISOLSM: Evaluation against in-situ measurements

    KAUST Repository

    Cai, Mick Y.

    2015-04-01

    The stable isotopes of water are useful tracers of water sources and hydrological processes. Stable water isotope-enabled land surface modeling is a relatively new approach for characterizing the hydrological cycle, providing spatial and temporal variability for a number of hydrological processes. At the land surface, the integration of stable water isotopes with other meteorological measurements can assist in constraining surface heat flux estimates and discriminate between evaporation (E) and transpiration (T). However, research in this area has traditionally been limited by a lack of continuous in-situ isotopic observations. Here, the National Centre for Atmospheric Research stable isotope-enabled Land Surface Model (ISOLSM) is used to simulate the water and energy fluxes and stable water isotope variations. The model was run for a period of one month with meteorological data collected from a coastal sub-tropical site near Sydney, Australia. The modeled energy fluxes (latent heat and sensible heat) agreed reasonably well with eddy covariance observations, indicating that ISOLSM has the capacity to reproduce observed flux behavior. Comparison of modeled isotopic compositions of evapotranspiration (ET) against in-situ Fourier Transform Infrared spectroscopy (FTIR) measured bulk water vapor isotopic data (10. m above the ground), however, showed differences in magnitude and temporal patterns. The disparity is due to a small contribution from local ET fluxes to atmospheric boundary layer water vapor (~1% based on calculations using ideal gas law) relative to that advected from the ocean for this particular site. Using ISOLSM simulation, the ET was partitioned into E and T with 70% being T. We also identified that soil water from different soil layers affected T and E differently based on the simulated soil isotopic patterns, which reflects the internal working of ISOLSM. These results highlighted the capacity of using the isotope-enabled models to discriminate

  18. Using heat to characterize streambed water flux variability in four stream reaches

    Science.gov (United States)

    Essaid, H.I.; Zamora, C.M.; McCarthy, K.A.; Vogel, J.R.; Wilson, J.T.

    2008-01-01

    Estimates of streambed water flux are needed for the interpretation of streambed chemistry and reactions. Continuous temperature and head monitoring in stream reaches within four agricultural watersheds (Leary Weber Ditch, IN; Maple Creek, NE; DR2 Drain, WA; and Merced River, CA) allowed heat to be used as a tracer to study the temporal and spatial variability of fluxes through the streambed. Synoptic methods (seepage meter and differential discharge measurements) were compared with estimates obtained by using heat as a tracer. Water flux was estimated by modeling one-dimensional vertical flow of water and heat using the model VS2DH. Flux was influenced by physical heterogeneity of the stream channel and temporal variability in stream and ground-water levels. During most of the study period (April-December 2004), flux was upward through the streambeds. At the IN, NE, and CA sites, high-stage events resulted in rapid reversal of flow direction inducing short-term surface-water flow into the streambed. During late summer at the IN site, regional ground-water levels dropped, leading to surface-water loss to ground water that resulted in drying of the ditch. Synoptic measurements of flux generally supported the model flux estimates. Water flow through the streambed was roughly an order of magnitude larger in the humid basins (IN and NE) than in the arid basins (WA and CA). Downward flux, in response to sudden high streamflows, and seasonal variability in flux was most pronounced in the humid basins and in high conductivity zones in the streambed. Copyright ?? 2008 by the American Society of Agronomy, Crop Science Society of America, and Soil Science Society of America. All rights reserved.

  19. Heat as a tool for studying the movement of ground water near streams

    Science.gov (United States)

    Stonestrom, David A.; Constantz, Jim

    2003-01-01

    and practical constraints. As an alternative, naturally occurring variations in temperature can be used to track (or trace) the heat carried by flowing water. The hydraulic transport of heat enables its use as a tracer. Differences between temperatures in the stream and surrounding sediments are now being analyzed to trace the movement of ground water to and from streams. As shown in the subsequent chapters of this circular, tracing the transport of heat leads to a better understanding of the magnitudes and mechanisms of stream/ground-water exchanges, and helps quantify the resulting effects on stream and streambed temperatures. Chapter 1 describes the general principals and procedures by which the natural transport of heat can be utilized to infer the movement of subsurface water near streams. This information sets the foundation for understanding the advanced applications in chapters 2 through 8. Each of these chapters provides a case study, using heat tracing as a tool, of interactions between surface water and ground water for a different location in the western United States. Technical details of the use of heat as an environmental tracer appear in appendices.

  20. Enhanced heating of salty water and ice under microwaves: Molecular dynamics study

    OpenAIRE

    Tanaka, Motohiko; Sato, Motoyasu

    2008-01-01

    By molecular dynamics simulations, we have studied the enhanced heating process of salty ice and water by the electric field of applied microwaves at 2.5 GHz, and those in the range 2.5-10 GHz for the frequency dependence. We show that water molecules in salty ice are allowed to rotate in response to the microwave electric field to the extent comparable to those in pure water, because the molecules in salty ice are loosely tied by hydrogen bonds with adjacent molecules unlike the case of rigi...

  1. MODULAR AUTOMATED COMPLEX OF THE SOLAR WATER HEATING PLANT FOR AGRICULTURAL OBJECTS

    Directory of Open Access Journals (Sweden)

    Gazalov V. S.

    2015-11-01

    Full Text Available The article deals with the system, providing automatic control of the solar water heating system with the abilities to store in internal memory and to transmit by the cellular network the information about the conditions of the plant and the occurring failure conditions. The common principles of the building the automatic system with the modular principles are shown. The article solves the issue about the quality of the water supply through the quality parameters which provided by the considered system. The methods of the active and passive loss minimizing of the heat of the water in the tank are shown. The usage of the active loss minimizing system was considered. The block-scheme of the implementation of the automatic system with described abilities are shown. The compulsory and auxiliary blocks of the automatic system are shown. The algorithm of the checking of the water supply quality parameters was presented. The study considers methods of the storing of the parameters of the working conditions of the plant and the occurring failure modes as well as the remote information of the attending personnel by the cellular networks. The advantages of the conducting of the system log are shown. The preliminary calculation of the memory capacity for storing the system log was completed. The advantages of the described automatic system with relation to the constructing, controlling, service and research of the described solar water heating systems are shown

  2. Enhancement of the thermal polarization of water via heat flux and dipole moment dynamic correlations.

    Science.gov (United States)

    Armstrong, Jeff; Lervik, Anders; Bresme, Fernando

    2013-11-27

    It has been recently shown that liquid water polarizes as a response to a temperature gradient. This polarization effect can be significant for temperature gradients that can be achieved at micro and nanoscales. In this paper we investigate the dependence of the polarization response of liquid and supercritical water at different thermodynamic conditions using both equilibrium and nonequilibrium molecular dynamics simulations for the extended point charge water model. We find that the thermal polarization features a nonmonotonic behavior with temperature, reaching a maximum response at specific thermodynamic states. We show that the thermal polarization is maximized when the density of states of the heat flux and dipole moment correlation functions feature the strongest overlap. The librational modes of water are shown to play an important role in determining this behavior as well as the heat transport mechanism in water. The librational frequencies show a significant dependence with temperature and pressure. This dependence provides a microscopic mechanism to explain the observed maximization of the thermal-polarization effect. Our work provides new microscopic insights on the mechanism determining the orientation of polar fluids under thermal gradients, as well as new strategies to maximize their orientation by manipulating the dynamic correlations between the heat flux and the sample dipole moment.

  3. Influence of drying temperature, water content, and heating rate on gelatinization of corn starches.

    Science.gov (United States)

    Altay, Filiz; Gunasekaran, Sundaram

    2006-06-14

    The gelatinization properties of starch extracted from corn and waxy corn dried at different temperatures were determined at various water contents and heating rates by differential scanning calorimetry. All gelatinization transition temperatures increased with drying temperature and heating rate. Onset and peak temperatures remained relatively constant, whereas end temperature decreased in the presence of excess water. The gelatinization enthalpy (deltaH(g)) of corn starch decreased with drying temperature at 50% water; however, it remained constant for waxy corn starch. The effects of water content and heating rate on deltaH(g) were dependent on each other. The minimum water levels required for gelatinization of starch extracted from corn dried at 20 and 100 degrees C are 21 and 29%, respectively. The activation energy (E(a)) was calculated using an Arrhenius-type equation and two first-order models; the degree of conversion (alpha) was predicted using a newly proposed model that produced good results for both E(a) and alpha.

  4. Experimental study on the heat transfer characteristics of a nuclear reactor containment wall cooled by gravitationally falling water

    Science.gov (United States)

    Pasek, Ari D.; Umar, Efrison; Suwono, Aryadi; Manalu, Reinhard E. E.

    2012-06-01

    Gravitationally falling water cooling is one of mechanism utilized by a modern nuclear Pressurized Water Reactor (PWR) for its Passive Containment Cooling System (PCCS). Since the cooling is closely related to the safety, water film cooling characteristics of the PCCS should be studied. This paper deals with the experimental study of laminar water film cooling on the containment model wall. The influences of water mass flow rate and wall heat rate on the heat transfer characteristic were studied. This research was started with design and assembly of a containment model equipped with the water cooling system, and calibration of all measurement devices. The containment model is a scaled down model of AP 1000 reactor. Below the containment steam is generated using electrical heaters. The steam heated the containment wall, and then the temperatures of the wall in several positions were measure transiently using thermocouples and data acquisition. The containment was then cooled by falling water sprayed from the top of the containment. The experiments were done for various wall heat rate and cooling water flow rate. The objective of the research is to find the temperature profile along the wall before and after the water cooling applied, prediction of the water film characteristic such as means velocity, thickness and their influence to the heat transfer coefficient. The result of the experiments shows that the wall temperatures significantly drop after being sprayed with water. The thickness of water film increases with increasing water flow rate and remained constant with increasing wall heat rate. The heat transfer coefficient decreases as film mass flow rate increase due to the increases of the film thickness which causes the increasing of the thermal resistance. The heat transfer coefficient increases slightly as the wall heat rate increases. The experimental results were then compared with previous theoretical studied.

  5. Surface-selective laser sintering of thermolabile polymer particles using water as heating sensitizer

    Energy Technology Data Exchange (ETDEWEB)

    Antonov, E N; Krotova, L I; Minaev, N V; Minaeva, S A; Mironov, A V; Popov, V K [Institute on Laser and Information Technologies of the Russian Academy of Sciencies, Troitsk, Moscow (Russian Federation); Bagratashvili, V N [Department of Chemistry, M.V. Lomonosov Moscow State University, Moscow (Russian Federation)

    2015-11-30

    We report the implementation of a novel scheme for surface-selective laser sintering (SSLS) of polymer particles, based on using water as a sensitizer of laser heating and sintering of particles as well as laser radiation at a wavelength of 1.94 μm, corresponding to the strong absorption band of water. A method of sintering powders of poly(lactide-co-glycolide), a hydrophobic bioresorbable polymer, after modifying its surface with an aqueous solution of hyaluronic acid is developed. The sintering thresholds for wetted polymer are by 3 – 4 times lower than those for sintering in air. The presence of water restricts the temperature of the heated polymer, preventing its thermal destruction. Polymer matrices with a developed porous structure are obtained. The proposed SSLS method can be applied to produce bioresorbable polymer matrices for tissue engineering. (interaction of laser radiation with matter. laser plasma)

  6. Enhanced heating of salty ice and water under microwaves: molecular dynamics study.

    Science.gov (United States)

    Tanaka, Motohiko; Sato, Motoyasu

    2008-01-01

    Through the use of molecular dynamics simulations, we have studied the enhanced heating of salty ice and water by the electric field of applied microwaves at 2.5 GHz, and in the range of 2.5-10 GHz for the frequency dependence. We show that water molecules in salty ice are allowed to rotate in response to the microwave electric field to the extent comparable to those in pure water because the molecules in salty ice are loosely tied by hydrogen bonds with adjacent molecules unlike rigidly bonded pure ice. The weakening of hydrogen-bonded network of molecules in salty ice is mainly due to the electrostatic effect of salt ions rather than the short-range geometrical (size) effect of salt since the presence of salt ions with small radii causes similar enhanced heating.

  7. Flow resistance characteristics of water in narrow annulus during heat exchange

    Institute of Scientific and Technical Information of China (English)

    SUN Li-cheng; YAN Chang-qi; SUN Zhong-ning; ZHANG Qing-hua

    2003-01-01

    Considering the special resistance characteristics of fluids flowing through ducts with small gaps, experiments are performed to investigate the resistance characteristics of single-phase water, which is forced to flow through vertical annuli. The gap sizes are 0.9, 1.4 and 2.4mm, respectively. The experiments are conducted under condition of 1atm. The water in the annuli is heated by high temperature water reversely flowing through the inner tube and the outer annulus. The results show that the flow pattern begin to change from laminar to turbulent before Reynolds number approaches 2000, the flow resistance in annulus has little relations with the temperature difference and ways of being heated, but mainly depends on the ratio of mass flux to the width of annulus.

  8. 10 CFR 431.107 - Uniform test method for the measurement of energy efficiency of commercial heat pump water...

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 3 2010-01-01 2010-01-01 false Uniform test method for the measurement of energy efficiency of commercial heat pump water heaters. 431.107 Section 431.107 Energy DEPARTMENT OF ENERGY ENERGY... method for the measurement of energy efficiency of commercial heat pump water heaters. Energy...

  9. Water heating solar system for popular houses; Sistema solar de aquecimento de agua para residencias populares

    Energy Technology Data Exchange (ETDEWEB)

    Mogawer, Tamer; Souza, Teofilo Miguel de [Universidade Estadual Paulista (UNESP), Guaratingueta, SP (Brazil). Centro de Energias Renovaveis], e-mail: teofilo@feg.unesp.br

    2004-07-01

    In this paper we present a case study for the design of a low cost solar heating system for a popular residence in an isolated rural community in the state of Rio Grande do Norte. This scaling can be extended to several rural communities that are in the same situation in Brazil as well as the wider use of solar power between the low-income people who do not have the benefits of electricity in their homes or want to have a lower cost of electricity. In this context, there are very interesting alternatives, among which is the replacement of electric heating bath water by heating by solar energy. According to several sources the electric shower, as it is now simple and extremely cheap, is the villain of the national electrical system. It is used in peak hours of consumption, something like 10% of electric generating capacity installed in Brazil, forcing many industries to switch off the machines because of the high cost of electricity during this period. Using the heating by solar energy, we can reduce consumption of electric shower and also increase the use of clean energy in popular homes and in isolated rural communities. This paper will address the use of solar energy with the basic purpose of heating water for bathing in popular residences and in isolated rural areas, using low cost systems, built with easily materials that is found in any area of the country. (author)

  10. Heat treatment's effects on hydroxyapatite powders in water vapor and air atmosphere

    Science.gov (United States)

    Karabulut, A.; Baştan, F. E.; Erdoǧan, G.; Üstel, F.

    2015-03-01

    Hydroxyapatite (HA; Ca10(PO4)6(OH)2) is the main chemical constituent of bone tissue (~70%) as well as HA which is a calcium phosphate based ceramic material forms inorganic tissue of bone and tooth as hard tissues is used in production of prosthesis for synthetic bone, fractured and broken bone restoration, coating of metallic biomaterials and dental applications because of its bio compatibility. It is known that Hydroxyapatite decomposes with high heat energy after heat treatment. Therefore hydroxyapatite powders that heated in water vapor will less decomposed phases and lower amorphous phase content than in air atmosphere. In this study high purity hydroxyapatite powders were heat treated with open atmosphere furnace and water vapor atmosphere with 900, 1000, 1200 °C. Morphology of same powder size used in this process by SEM analyzed. Chemical structures of synthesized coatings have been examined by XRD. The determination of particle size and morphological structure of has been characterized by Particle Sizer, and SEM analysis, respectively. Weight change of sample was recorded by thermogravimetric analysis (TGA) during heating and cooling.

  11. Natural Convective Heat and Mass Transfer of Water with Corrosion Products at Super—Critical Pressures under Cooling COnditions

    Institute of Scientific and Technical Information of China (English)

    Pei-XueJiang; Ze-PeiRen; 等

    1993-01-01

    A numerical study is reported of laminar natural convective heat and mass transfer on a vertical cooled plate for water containing metal corrosion products at super-critical pressures.The influence of variable properties at super-critical pressures on natural convertion has been analyzed.The difference between heat and mass transfer under cooling or heating conditions is also discussed and some correlations for heat and mass transfer under cooling conditions are recommended.

  12. Heat, chloride, and specific conductance as ground water tracers near streams

    Science.gov (United States)

    Cox, M.H.; Su, G.W.; Constantz, J.

    2007-01-01

    Commonly measured water quality parameters were compared to heat as tracers of stream water exchange with ground water. Temperature, specific conductance, and chloride were sampled at various frequencies in the stream and adjacent wells over a 2-year period. Strong seasonal variations in stream water were observed for temperature and specific conductance. In observation wells where the temperature response correlated to stream water, chloride and specific conductance values were similar to stream water values as well, indicating significant stream water exchange with ground water. At sites where ground water temperature fluctuations were negligible, chloride and/or specific conductance values did not correlate to stream water values, indicating that ground water was not significantly influenced by exchange with stream water. Best-fit simulation modeling was performed at two sites to derive temperature-based estimates of hydraulic conductivities of the alluvial sediments between the stream and wells. These estimates were used in solute transport simulations for a comparison of measured and simulated values for chloride and specific conductance. Simulation results showed that hydraulic conductivities vary seasonally and annually. This variability was a result of seasonal changes in temperature-dependent hydraulic conductivity and scouring or clogging of the streambed. Specific conductance fits were good, while chloride data were difficult to fit due to the infrequent (quarterly) stream water chloride measurements during the study period. Combined analyses of temperature, chloride, and specific conductance led to improved quantification of the spatial and temporal variability of stream water exchange with shallow ground water in an alluvial system. ?? 2007 National Ground Water Association.

  13. THE HARDWARE SOURCES OF THE AUTOMATION OF THE SOLAR WATER HEATING OF THE AGRICULTURE PLANTS

    Directory of Open Access Journals (Sweden)

    Gazalov V. S.

    2016-01-01

    Full Text Available The article deals with the necessity of the uninterrupted control of the work quality of the solar heating system. The advantages of the microcontroller systems, which gave their evolution in the last years, are shown. The possibilities of the usage of the microcontroller systems for carrying the work quality control are shown. The electrical principal scheme of the system of the automatic control of the solar water heating which allow to control the work quality control are shown. The system was divided into interconnected parts. The methods of the temperature control by the electronic temperature sensors 18B20, water control by the optical pair with open channel and water quantity meter with the optical wheel, water level in the tank by the ultrasonic sensor of the distance and level of the solar radiation by the pyranometer are shown. The necessarily calculation of the geometric tank sizes and water velocity in the solar collector are carried out. The corresponding hardware resources of the PIC microcontrollers like hardware counters, timer with the ability to allow counting by the external signal (Gate Control, analog-digital converter and fixed voltage reference module are described. The algorithms of the control of the water temperature in the tank and the control of the filling the tank with the hot water from the solar collector are described. The methods of the transmitting information to the operator are shown. The advantages of the microcontroller control are described

  14. Side-by-Side Testing of Water Heating Systems: Results from the 2013–2014 Evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Colon, Carlos [Florida Solar Energy Center, Cocoa, FL (United States)

    2017-07-01

    The Florida Solar Energy Center (FSEC) completed a fourth year-long evaluation on residential hot water heating systems in a laboratory environment (east central Florida, hot-humid climate). The evaluation studied the performance of five hot water systems (HWS) plus a reference baseline system for each fuel, (i.e., electric and natural gas). Electric HWS consisted of two residential electric heat pump water heaters (HPWHs, 60 and 80 gallons), a solar thermal system using a polymer absorber (glazed) collector with 80-gallon storage and a duplicate 50-gallon standard electric water heater with added cap and wrap insulation. Baseline performance data were collected from a standard 50-gallon electric water heater of minimum code efficiency to compare energy savings. Similarly, a standard 40-gallon upright vented natural gas water heater served as baseline for the natural gas fuel category. The latter, having a larger jacket diameter [18 in., with an energy factor (EF) of 0.62] with increased insulation, replaced a former baseline (17 in. diameter, EF = 0.59) that served during three previous testing rotations (2009–2013). A high-efficiency, condensing natural gas hybrid water heater with 27-gallon buffered tank was also tested and compared against the gas baseline. All systems underwent testing simultaneously side-by-side under the criteria specified elsewhere in this report.

  15. Safe corrosion inhibitor for treating cooling water on heat power engineering plants

    Science.gov (United States)

    Nikolaeva, L. A.; Khasanova, D. I.; Mukhutdinova, E. R.; Safin, D. Kh.; Sharifullin, I. G.

    2017-08-01

    Heat power engineering (HPE) consumes significant volumes of water. There are, therefore, problems associated with corrosion, biological fouling, salt deposits, and sludge formation on functional surfaces of heat power equipment. One of the effective ways to solve these problems is the use of inhibitory protection. The development of new Russian import-substituting environmentally friendly inhibitors is very relevant. This work describes experimental results on the OPC-800 inhibitor (TU 2415-092-00206 457-2013), which was produced at Karpov Chemical Plant and designed to remove mineral deposits, scale, and biological fouling from the surfaces of water-rotation node systems on HPE objects. This reagent is successfully used as an effective corrosion inhibitor in the water recycling systems of Tatarstan petrochemical enterprises. To save fresh make-up water, the circulating system is operated in a no-blow mode, which is characterized by high evaporation and salt content coefficients. It was experimentally found that corrosion rate upon treatment of recycled water with the OPC-800 inhibitor is 0.08-0.10 mm/year. HPE mainly uses inhibitors based on oxyethylidene diphosphonic (OEDPA) and nitrilotrimethylphosphonic (NTMPA) acids. The comparative characteristic of inhibition efficiency for OPC-800 and OEDF-Zn-U2 is given. The results obtained indicate that OPC-800 can be used as an inhibitor for treatment of cooling water in HPE plants. In this case, it is necessary to take into account the features of water rotation of a thermal power plant.

  16. Competence in water-borne heating systems in buildings; Kompetanse innen vannbaarene varmesystemer i bygg

    Energy Technology Data Exchange (ETDEWEB)

    Jarstein, Stig; Palm, Linn Therese; Naess, Bente Haukland; Nossum, Aase; Johnsen, Morten

    2009-01-15

    Trade participants in water-borne heating systems in buildings has experienced mistakes in all phases and of all participants of a project. When water-borne heating system functions, there is almost no follow up. This report is based on a qualitative survey where a several central participants, who on a daily basis are involved in projects with water-borne heating systems, are interviewed or have participated in focus group meetings. Following points illustrate experiences made by the operators in occasions where competence in trade is insufficiencies and mistakes occur: - Property developer lacks ordering competence and has problems in ordering quality. Consultant submit services of minor quality. Performance is of another quality than the supplier. Administration / maintenance lacks competence in how to run the system and without introduction and training in the heating system they take over a system that is over dimensioned and hard to regulate. The trade as a whole knows all the challenges, but the participants gives mainly the impression that the fault is lac of competence for all the other participants - not them self. This report points out measures and Enova can support competence improving measures which on long term will improve the quality from the participants. The trade is recommended to look into project execution, how competence is involved at the right moment, improving of control and documentation routines and at termination / hand over. (AG).14 refs., 14 figs., 2 tabs

  17. Using reclaimed water as make-up water for a district heating system: a case study in Beijing.

    Science.gov (United States)

    Yajun, Zhang; Huizhen, Wang; Ping, Xu; Cuimin, Feng

    2009-01-01

    Make-up water used for a district heating system in Beijing is about 63 kg/m(2).a, so the total quantity of make-up water is over 10 million m(3) per year. Water deficiency is very serious in Beijing. Using reclaimed water as make-up water is one of the important measures to relieve water crises of the city. This study is mainly on nanofiltration (NF) process. The reclaimed water for the experiment is the effluent of The Sixth Water Plant, an urban reclaimed water plant in Beijing. Micro-filter (MF) and activated carbon filtration are used as pretreatment units to eliminate turbidity, organic matter in reclaimed water to avoid contamination and scale on the surface of NF membrane. Four SAEHAN NE-90 membrane elements with an array of 2-1-1 are selected for the NF unit and the flow rate is controlled around 1 m(3)/h. Through the test, it has been verified that NF membrane has high removal rate to the salt and impurity of reclaimed water. The average salt removal rate of the system is more than 94%, while the rejections of bivalent ions are more than 98%. The removal rates of organic matter, NH(3)-N and TP are 77%, 96% and 84% respectively. Temperature is a main influence of the process. When temperature is increasing, the permeate flux is increasing as well. The operating pressure is an important factor effecting membrane flux also. By the data comparison it is confirmed that the appropriate operating pressure and the water recovery of NF system are 0.75 MPa and 63.5% respectively.

  18. Experimental evaluation of a heat pump for the water-supply heating of a public swimming pool

    Science.gov (United States)

    López, R.; Vaca, M.; Terres, H.; Lizardi, A.; Morales, J.; Chávez, S.

    2017-01-01

    In this work the analysis of the thermodynamic behavior of heat pumps (HP) which supply the energy needed in the public pool at the Aquatic Center of Azcapotzalco was performed. There are 18 installed HP’s but only those needed to provide the energy required are alternately activated. The evaluation was conducted during May and June of 2015. We selected one of the HP to implement temperature and pressure gauges at the inlet and outlet of the compressor. The measurements were made every day at three times, 6:30, 13:00 and 18:00 hours. In a period of 24 hours, 1 000 L evaporated, there was no variation registered overnight, since the pool was covered with plastic to avoid loss of the fluid. The heat pump provided 150 kW to maintain the water temperature at the right level of operation, namely 28 °C. The coefficients of performance (COP) of the HP were 6.39 at 6:30, 7.42 at 13:00 and 7:32 at 18:00 hrs., values which are very close to the one provided by the manufacturer.

  19. Solar heating and hot water system installed at Southeast of Saline, Unified School District 306, Mentor, Kansas

    Science.gov (United States)

    1979-01-01

    The solar system, installed in a new building, was designed to provide 52 percent of the estimated annual space heating load and 84 percent of the estimated annual potable hot water requirement. The liquid flat plate collectors are ground-mounted and cover a total area of 5125 square feet. The system will provide supplemental heat for the school's closed-loop water-to-air heat pump system and domestic hot water. The storage medium is water inside steel tanks with a capacity of 11,828 gallons for space heating and 1,600 gallons for domestic hot water. The solar heating facility is described and drawings are presented of the completed system which was declared operational in September 1978, and has functioned successfully since.

  20. Calculation of heat capacities of light and heavy water by path-integral molecular dynamics

    Science.gov (United States)

    Shiga, Motoyuki; Shinoda, Wataru

    2005-10-01

    As an application of atomistic simulation methods to heat capacities, path-integral molecular dynamics has been used to calculate the constant-volume heat capacities of light and heavy water in the gas, liquid, and solid phases. While the classical simulation based on conventional molecular dynamics has estimated the heat capacities too high, the quantum simulation based on path-integral molecular dynamics has given reasonable results based on the simple point-charge/flexible potential model. The calculated heat capacities (divided by the Boltzmann constant) in the quantum simulation are 3.1 in the vapor H2O at 300 K, 6.9 in the liquid H2O at 300 K, and 4.1 in the ice IhH2O at 250 K, respectively, which are comparable to the experimental data of 3.04, 8.9, and 4.1, respectively. The quantum simulation also reproduces the isotope effect. The heat capacity in the liquid D2O has been calculated to be 10% higher than that of H2O, while it is 13% higher in the experiment. The results demonstrate that the path-integral simulation is a promising approach to quantitatively evaluate the heat capacities for molecular systems, taking account of quantum-mechanical vibrations as well as strongly anharmonic motions.

  1. Natural convection heat transfer of water in a horizontal circular gap

    Institute of Scientific and Technical Information of China (English)

    SU Guanghui; Kenichiro Sugiyama; WU Yingwei

    2007-01-01

    An experimental study on the natural convection heat transfer on a horizontal downward facing heated surface in a water gap was carried out under atmospheric pressure conditions. A total of 700 experimental data points were correlated using Rayleigh versus Nusselt number in various forms, based on different independent variables. The effects of different characteristic lengths and film temperatures were discussed. The results show that the buoyancy force acts as a resistance force for natural convecti on beat transfer ona downward facing horizontal heated surface in a confined space. For the estimation of the natural convection heat transfer under the present conditions, empirical correlations in which Nusselt number is expressed as a function of the Rayleigh number, or both Rayleigh and Prandtl numbers, may be used. When it is accurately predicted, the Nusselt number is expressed as a function of the Rayleigh and Prandtl numbers, as well as the gap width-to-heated surface diameter ratio; and uses the temperature difference between the heated surface and the ambient fluid in the definition of Rayleigh number. The characteristic length is the gap size and the film temperature is the average fluid temperature.

  2. Laminar convective heat transfer characteristic of Al2O3/water nanofluid in a circular microchannel

    Science.gov (United States)

    Trinavee, K.; Gogoi, T. K.; Pandey, M.

    2016-10-01

    In this study, laminar convective heat transfer characteristics Al2O3/water nanofluid in a circular microchannel is investigated using a two-phase (discrete phase) model. The computational fluid dynamic code FLUENT (ANSYS) is employed to solve the coupled momentum and energy equations with the boundary conditions of uniform wall heat flux and velocity at channel inlet. Detail analysis is done showing variation of wall temperature, fluid bulk mean temperature, heat transfer coefficient, Nusselt number, shear stress, friction, pressure drop, entropy generation etc. along the microchannel at two particle volume concentrations (1% and 4%) of the nanofluid. Comparison of results is provided between base and nanofluid and also for two cases, one with constant property and the other with variable temperature thermal conductivity and viscosity. Results show that heat transfer is enhanced in case of the nanofluid with low entropy generation and the heat transfer parameters increase with increase in nanoparticle volume concentration and Reynolds number. However, use of nanofluid also causes increase in pressure drop and shear stress. A comparison of the constant and variable property model showed that heat transfer is further enhanced; entropy, shear stress and pressure drop further decrease when temperature dependent properties of the nanofluid are considered instead of constant properties.

  3. Numerical Study of Thermal Performance of Phase Change Material Energy Storage Floor in Solar Water Heating System

    Institute of Scientific and Technical Information of China (English)

    ZENG Ruo-lang; WANG Xin; ZHANG Yin-ping; DI Hong-fa; ZHANG Qun-li

    2009-01-01

    The conventional solar heating floor system contains a big water tank to store energy in the day time for heating at night,which takes much building space and is very heavy.In order to reduce the water tank velume even to cancel the tank,a novel structure of integrated water pipe floor heating system using shape-stabi-lized phase change materials (SSPCM) for thermal energy storage was developed.A numerical model was devel-oped to analyze the performance of SSPCM floor heating system under the intermittent heating condition,which was verified by our experimental data.The thermal performance of the heating system and the effects of various factors on it were analyzed numerically.The factors including phase transition temperature,heat of fusion,ther-real conductivity of SSPCM and thermal conductivity of the decoration material were analyzed.The results show that tm and kd are the most import influencing factors on the thermal performance of SSPCM floor heating sys-tem,since they determine the heat source temperature and thermal resistance between SSPCM plates and indoor air,respectively.Hm should be large to store enough thermal energy in the day time for nighttimes heating.The effects of KP can be ignored in this system.The SSPCM floor heating system has potential of making use of the daytime solar energy for heating at night efficiently in various climates when its structure is properly designed.

  4. Corrosion and Heat Transfer Characteristics of Water Dispersed with Carboxylate Additives and Multi Walled Carbon Nano Tubes

    Science.gov (United States)

    Moorthy, Chellapilla V. K. N. S. N.; Srinivas, Vadapalli

    2016-10-01

    This paper summarizes a recent work on anti-corrosive properties and enhanced heat transfer properties of carboxylated water based nanofluids. Water mixed with sebacic acid as carboxylate additive found to be resistant to corrosion and suitable for automotive environment. The carboxylated water is dispersed with very low mass concentration of carbon nano tubes at 0.025, 0.05 and 0.1 %. The stability of nanofluids in terms of zeta potential is found to be good with carboxylated water compared to normal water. The heat transfer performance of nanofluids is carried out on an air cooled heat exchanger similar to an automotive radiator with incoming air velocities across radiator at 5, 10 and 15 m/s. The flow Reynolds number of water is in the range of 2500-6000 indicating developing flow regime. The corrosion resistance of nanofluids is found to be good indicating its suitability to automotive environment. There is a slight increase in viscosity and marginal decrease in the specific heat of nanofluids with addition of carboxylate as well as CNTs. Significant improvement is observed in the thermal conductivity of nanofluids dispersed with CNTs. During heat transfer experimentation, the inside heat transfer coefficient and overall heat transfer coefficient has also improved markedly. It is also found that the velocity of air and flow rate of coolant plays an important role in enhancement of the heat transfer coefficient and overall heat transfer coefficient.

  5. Rate of heat transfer in polypropylene tubes in solar water heaters

    Energy Technology Data Exchange (ETDEWEB)

    Razavi, J.; Mahmoodi, M. [Sharif University of Technology, Tehran (Iran). Chemical Engineering Dept.; Riazi, M.R. [Kuwait Univ., Safat (Kuwait). Chemical Engineering Dept.

    2003-06-01

    A heat transfer rate was determined for polypropylene tubes in solar water heaters for the Reynolds number range 800-5600. Experiments were conducted in ambient temperatures of 34 to 37 {sup o}C. Data were correlated in the form of Nusselt numbers as: Nu=0.0015 Re{sup 0.75}Pr{sup 1/3} with correlation coefficient of 0.95. Such data can be used to predict heat transfer rates in a polypropylene solar heater in Tehran where the experiments were performed. An application of the results is shown in an example. (author)

  6. Heat Pump Water Heater Ducting Strategies with Encapsulated Attics in Climate Zones 2 and 4

    Energy Technology Data Exchange (ETDEWEB)

    Sweet, M. L. [Southface Energy Inst., Atlanta, GA (United States); Francisco, A. [Southface Energy Inst., Atlanta, GA (United States); Roberts, S. G. [Southface Energy Inst., Atlanta, GA (United States)

    2016-05-01

    The focus of this study is on the performance of HPWHs with several different duct configurations and their effects on whole building heating, cooling, and moisture loads. A.O. Smith 60 gallon Voltex (PHPT-60) heat pump water heaters (HPWHs) were included at two project sites and ducted to or located within spray foamed encapsulated attics. The effect of ducting a HPWH's air stream does not diminish its efficiency if the ducting does not reduce intake air temperature, which expands HPWH application to confined areas.

  7. Application of an intermediate LWR for electricity production and hot-water district heating

    Energy Technology Data Exchange (ETDEWEB)

    1983-05-01

    The objective of the study is to evaluate the technical and economic feasibility of a 400 MWe Consolidated Nuclear Steam System (CNSS) for supplying district heat to the Minneapolis/St. Paul area. A total of three CNSS reactor sites, located various distances from the Minneapolis-St. Paul area load center, are evaluated. The distance from the load center is determined by the credited safety features of the plant design. Each site is also evaluated for three different hot water supply/return temperatures providing a total of nine CNSS study cases. The cost of district heat delivered to the load center is determined for each case.

  8. 太阳能-空气复合热源热泵热水系统%Solar-air composite heat source heat pump hot water system

    Institute of Scientific and Technical Information of China (English)

    王岗; 全贞花; 赵耀华; 侯隆澍; 徐俊芳; 邓月超

    2014-01-01

    In the light of low efficiency of photovoltaic power generation and the problems of air source heat pump applied in cold regions, a composite heat exchanger evaporator is developed and a new type of solar-air composite heat source heat pump hot water system is designed in this study, which is comprised of independent solar photovoltaic-thermal collector based on flat plate micro heat pipe and air source heat pump. The performance of heat pump hot water system is evaluated experimentally under different operating conditions, including water temperature of the tank, heating time of hot water, suction and discharge pressure, consumption of compressor power and heat pump coefficient of performance (COP), etc. Experimental results show that at ambient temperature of 5℃, 10℃ and 15℃, with 73 L hot water heated by heat pump and water temperature in the tank ranged from 15℃ to 50℃, the running time of composite heat source operation is shorter than that of separate air heat source operation, decreased by 5.14%, 10.29% and 11.38%, respectively. COPs are increased by 5.99%, 9.28%and 11.96%, respectively.%针对光伏发电效率较低和空气源热泵在寒冷地区应用中存在的问题,研发了一种新型复合蒸发器,将平板微热管阵列太阳能光伏光热(PV/T)集热器与空气源热泵相结合,组成新型太阳能-空气复合热源热泵热水系统。并对该热水系统在不同运行工况下的水箱水温、吸排气压力、压缩机功率和性能等进行了实验研究。实验结果表明,在环境温度分别为5、10和15℃的条件下,热泵加热73 L水,水温从15℃加热到50℃时,双热源运行工况的加热时间比单空气热源运行工况依次缩短了5.14%、10.29%和11.38%,COP依次提高了5.99%、9.28%和11.96%。

  9. Effect Of Cuo-Distilled Water Based Nanofluids On Heat Transfer Characteristics And Pressure Drop Characteristics.

    Directory of Open Access Journals (Sweden)

    SANDEEP KUMAR

    2014-09-01

    Full Text Available In this paper, the heat transfer and pressure drop characteristics of the distilled water and the copper oxide-distilled water based nanofluid flowing in a horizontal circular pipe under constant heat flux condition are studied. Copper oxide nanoparticles of 40nm size are dispersed in distilled water using sodium dodecyl sulphate as surfactant and sonicated the nanofluid for three hour. Both surfactant and sonication increases the stability of the nanofluid. The nanofluids are made in three different concentration i.e. 0.1 Vol. %, 0.25 Vol. % and 0.50 Vol. %. The thermal conductivity is measured by KD2 PRO, density with pycnometer, viscosity with Brookfield LVDV-III rheometer. The results show that the thermal conductivity increases with both temperature and concentration. The viscosity and density increases with concentration but decreases with temperature. The specific heat is calculated by model and it decreases with concentration. The experimental local Nusselt number of distilled water is compared with local Nusselt number obtained by the well known shah equation for laminar flow under constant heat flux condition for validation of the experimental set up. The relative error is 4.48 % for the Reynolds number 750.9. The heat transfer coefficient increases with increase in both flow rate and concentration. It increases from 14.33 % to 46.1 % when the concentration is increased from 0.1 Vol. % to 0.5 Vol. % at 20 LPH flow rate. Friction factor decreases with increase in flow rate. It decreases 66.54 % when the flow rate increases from 10 LPH to 30 LPH for 0.1 Vol. %.

  10. Experimental investigation of forced convective heat transfer performance in nanofluids of Al2O3/water and CuO/water in a serpentine shaped micro channel heat sink

    Science.gov (United States)

    Sivakumar, A.; Alagumurthi, N.; Senthilvelan, T.

    2016-07-01

    The microchannels are device used to remove high heat fluxes from smaller area. In this experimental research work the heat transfer performance of nanofluids of Al2O3/water and CuO/water were compared. The important character of such fluids is the enhanced thermal conductivity, in comparison with base fluid without considerable alteration in physical and chemical properties. The effect of forced convective heat transfer coefficient was calculated using serpentine shaped microchannel heat exchanger. Furthermore we calculated the forced convective heat transfer coefficient of the nanofluids using theoretical correlations in order to compare the results with the experimental data. The heat transfer coefficient for different particle concentration and temperature were analysed using forced convection heat transfer using nanofluids. The findings indicate considerable enhancement in convective heat transfer coefficient of the nanofluids as compared to the basefluid. The results also shows that CuO/water nanofluid has increased heat transfer coefficient compared with Al2O3/water and base fluids. Moreover the experimental results indicate there is increased forced convective heat transfer coefficient with the increase in nano particle concentration.

  11. Novel Method for Measuring the Heat Collection Rate and Heat Loss Coefficient of Water-in-Glass Evacuated Tube Solar Water Heaters Based on Artificial Neural Networks and Support Vector Machine

    Directory of Open Access Journals (Sweden)

    Zhijian Liu

    2015-08-01

    Full Text Available The determinations of heat collection rate and heat loss coefficient are crucial for the evaluation of in service water-in-glass evacuated tube solar water heaters. However, the direct determination requires complex detection devices and a series of standard experiments, which also wastes too much time and manpower. To address this problem, we propose machine learning models including artificial neural networks (ANNs and support vector machines (SVM to predict the heat collection rate and heat loss coefficient without a direct determination. Parameters that can be easily obtained by “portable test instruments” were set as independent variables, including tube length, number of tubes, tube center distance, heat water mass in tank, collector area, final temperature and angle between tubes and ground, while the heat collection rate and heat loss coefficient determined by the detection device were set as dependent variables respectively. Nine hundred fifteen samples from in-service water-in-glass evacuated tube solar water heaters were used for training and testing the models. Results show that the multilayer feed-forward neural network (MLFN with 3 nodes is the best model for the prediction of heat collection rate and the general regression neural network (GRNN is the best model for the prediction of heat loss coefficient due to their low root mean square (RMS errors, short training times, and high prediction accuracies (under the tolerances of 30%, 20%, and 10%, respectively.

  12. Performance Analysis of Air-to-Water Heat Pump in Latvian Climate Conditions

    Science.gov (United States)

    Kazjonovs, Janis; Sipkevics, Andrejs; Jakovics, Andris; Dancigs, Andris; Bajare, Diana; Dancigs, Leonards

    2014-12-01

    Strategy of the European Union in efficient energy usage demands to have a higher proportion of renewable energy in the energy market. Since heat pumps are considered to be one of the most efficient heating and cooling systems, they will play an important role in the energy consumption reduction in buildings aimed to meet the target of nearly zero energy buildings set out in the EU Directive 2010/31/EU. Unfortunately, the declared heat pump Coefficient of Performance (COP) corresponds to a certain outdoor temperature (+7 °C), therefore different climate conditions, building characteristics and settings result in different COP values during the year. The aim of this research is to investigate the Seasonal Performance factor (SPF) values of air-to-water heat pump which better characterize the effectiveness of heat pump in a longer selected period of time, especially during the winter season, in different types of residential buildings in Latvian climate conditions. Latvia has four pronounced seasons of near-equal length. Winter starts in mid-December and lasts until mid-March. Latvia is characterized by cold, maritime climate (duration of the average heating period being 203 days, the average outdoor air temperature during the heating period being 0.0 °C, the coldest five-day average temperature being -20.7 °C, the average annual air temperature being +6.2 °C, the daily average relative humidity being 79 %). The first part of this research consists of operational air-towater heat pump energy performance monitoring in different residential buildings during the winter season. The second part of the research takes place under natural conditions in an experimental construction stand which is located in an urban environment in Riga, Latvia. The inner area of this test stand, where air-to-water heat pump performance is analyzed, is 9 m2. The ceiling height is 3 m, all external wall constructions (U = 0.16 W/(m2K)) have ventilated facades. To calculate SPF, the

  13. Analysis of the ability of water resources to reduce the urban heat island in the Tokyo megalopolis

    Energy Technology Data Exchange (ETDEWEB)

    Nakayama, Tadanobu, E-mail: nakat@nies.go.jp [Asian Environment Research Group, National Institute for Environmental Studies (NIES), 16-2 Onogawa, Tsukuba, Ibaraki 305-8506 (Japan); Process Hydrology Section, Centre for Ecology and Hydrology (CEH), Crowmarsh Gifford, Wallingford, Oxfordshire OX10 8BB (United Kingdom); Hashimoto, Shizuka [Faculty of Agriculture, Kyoto University, Sakyo-ku, Kyoto 606-8502 (Japan)

    2011-08-15

    Simulation procedure integrated with multi-scale in horizontally regional-urban-point levels and in vertically atmosphere-surface-unsaturated-saturated layers, was newly developed in order to predict the effect of urban geometry and anthropogenic exhaustion on the hydrothermal changes in the atmospheric/land and the interfacial areas of the Japanese megalopolis. The simulated results suggested that the latent heat flux in new water-holding pavement (consisting of porous asphalt and water-holding filler made of steel by-products based on silica compound) has a strong impact on hydrologic cycle and cooling temperature in comparison with the observed heat budget. We evaluated the relationship between the effect of groundwater use as a heat sink to tackle the heat island and the effect of infiltration on the water cycle in the urban area. The result indicates that effective management of water resources would be powerful for ameliorating the heat island and recovering sound hydrologic cycle there. - Highlights: > Simulation procedure with multi-scale was newly developed. > Latent heat flux in water-holding pavement had strong impact on hydrothermal changes. > Model predicted effect of urban geometry and anthropogenic exhaustion. > Effective management of water resources is powerful for ameliorating heat island. - This study indicates that effective management of water resources would be powerful for ameliorating the heat island and recovering sound hydrologic cycle in urban area.

  14. An experimental investigation of the interfacial condensation heat transfer in steam/water countercurrent stratified flow in a horizontal pipe

    Energy Technology Data Exchange (ETDEWEB)

    Chu, In Cheol; Yu, Seon Oh; Chun, Moon Hyun [Korea Advanced Institute of Science and Technology, Taejon (Korea, Republic of); Kim, Byong Sup; Kim, Yang Seok; Kim, In Hwan; Lee, Sang Won [Korea Electric Power Research Institute, Taejon (Korea, Republic of)

    1998-12-31

    An interfacial condensation heat transfer phenomenon in a steam/water countercurrent stratified flow in a nearly horizontal pipe has been experimentally investigated. The present study has been focused on the measurement of the temperature and velocity distributions within the water layer. In particular, the water layer thickness used in the present work is large enough so that the turbulent mixing is limited and the thermal stratification is established. As a result, the thermal resistance of the water layer to the condensation heat transfer is increased significantly. An empirical correlation of the interfacial condensation heat transfer has been developed. The present correlation agrees with the data within {+-} 15%. 5 refs., 6 figs. (Author)

  15. Urban "accidental" wetlands mediate water quality and heat exposure for homeless populations in a desert city

    Science.gov (United States)

    Palta, M.

    2015-12-01

    In urban settings where humans interact in complex ways with ecosystems, there may be hidden or unanticipated benefits (services) or harm (disservices) conferred by the built environment. We examined interactions of a highly vulnerable population, the homeless, with urban waterways and wetlands in the desert city of Phoenix, Arizona, U.S.A. Climate change models project increases in heat, droughts, and extreme floods for the southwestern U.S. These projected changes pose a number of problems for sustainability and quality of future water supply, and the ability of human populations to mitigate heat stress and avoid fatalities. Urban wetlands that are created "accidentally" (by water pooling in abandoned areas of the landscape) have many structural (e.g., soils and hydrology) and functional (e.g., high denitrification) elements that mimic natural, unaltered aquatic systems. Accidental wetland systems in the dry bed of the Salt River, fed by storm and waste water from urban Phoenix, are located within economically depressed sections of the city, and show the potential for pollutant and heat mitigation. We used a mixed-method socio-ecological approach to examine wetland ecosystem functions and the ways in which homeless populations utilize Salt River wetlands for ecosystem services. Interviews and trash surveys indicated that homeless people are accessing and utilizing the wetlands as a source of running water, for sanitary and heat mitigation services, and for recreation and habitation. Environmental monitoring demonstrated that the wetlands can provide a reliable source of running water, nutrient and pathogen removal, heat mitigation, and privacy, but they may also pose a health risk to individuals coming in contact with the water through drinking or bathing. Whether wetlands provided a net benefit vs. harm varied according to site, season, and particular service, and several tradeoffs were identified. For example, heat is highest during the summer storm season

  16. Heat and water transport in a polymer electrolyte fuel cell electrode

    Energy Technology Data Exchange (ETDEWEB)

    Mukherjee, Partha P [Los Alamos National Laboratory; Mukundan, Rangachary [Los Alamos National Laboratory; Borup, Rod L [Los Alamos National Laboratory; Ranjan, Devesh [TEXAS A& M UNIV

    2010-01-01

    In the present scenario of a global initiative toward a sustainable energy future, the polymer electrolyte fuel cell (PEFC) has emerged as one of the most promising alternative energy conversion devices for various applications. Despite tremendous progress in recent years, a pivotal performance limitation in the PEFC comes from liquid water transport and the resulting flooding phenomena. Liquid water blocks the open pore space in the electrode and the fibrous diffusion layer leading to hindered oxygen transport. The electrode is also the only component in the entire PEFC sandwich which produces waste heat from the electrochemical reaction. The cathode electrode, being the host to several competing transport mechanisms, plays a crucial role in the overall PEFC performance limitation. In this work, an electrode model is presented in order to elucidate the coupled heat and water transport mechanisms. Two scenarios are specifically considered: (1) conventional, Nafion{reg_sign} impregnated, three-phase electrode with the hydrated polymeric membrane phase as the conveyer of protons where local electro-neutrality prevails; and (2) ultra-thin, two-phase, nano-structured electrode without the presence of ionomeric phase where charge accumulation due to electro-statics in the vicinity of the membrane-CL interface becomes important. The electrode model includes a physical description of heat and water balance along with electrochemical performance analysis in order to study the influence of electro-statics/electro-migration and phase change on the PEFC electrode performance.

  17. Gas Engine-Driven Heat Pump Chiller for Air-Conditioning and Hot Water Supply Systems

    Science.gov (United States)

    Fujita, Toshihiko; Mita, Nobuhiro; Moriyama, Tadashi; Hoshino, Norimasa; Kimura, Yoshihisa

    In Part 1 of this study, the performance characteristics of a 457kW gas engine-driven heat pump (GHP) chiller have been obtained from a simulation model analysis for both cooling and heating modes and it has been found that the part-load characteristics of the GHP chiller are fairly well. On the back of Part 1, a computer simulation program has been developed for the evaluation of GHP chiller systems to compare with the other types of heat source systems for air-conditioning and hot water supply applications. The simulation program can be used to estimate annual energy consumption, annual CO2 emission, etc. of the systems with the data of monthly and hourly thermal loads on various buildings, outdoor air conditions, and characteristics of various components comprising the systems. By applying this to some cases of medium-scale hotel, office, shop, and hospital buildings, it has been found that the GHP chiller systems have advantages particularly in the cases of hotels and hospitals where a lot of hot water demand exists. It has also been found that the combination of a GHP chiller and a direct-fired absorption water chiller boiler (hot and chilled water generator) appears promising.

  18. Design and Development of Prototype Cylindrical Parabolic Solar Collector for Water Heating Application

    Directory of Open Access Journals (Sweden)

    Hrushikesh Bhujangrao Kulkarni

    2016-02-01

    Full Text Available Concentrating collectors absorbs solar energy and convert it into heat for generating hot water, steam at required temperature, which can be further used for solar thermal applications. The developing countries like India where solar energy is abundantly available; there is need to develop technology for harnessing solar energy for power production, but the main problem associated with concentrating solar power technology is the high cost of installation and low output efficiency. To solve this problem, a prototype cylindrical parabolic solar collector having aperture area of 1.89 m2 is designed and developed using low cost highly reflecting and absorbing material to reduce initial cost of project and improve thermal efficiency. ASHRAE Standard 93, 1986 was used to evaluate the thermal performance and it was observed that this system can generate hot water at an average temperature of 500C per day with an average efficiency of 49% which is considerable higher than flat plate solar collectors. Hot water produced by this system can be useful for domestic, agricultural, industrial process heat applications.Article History: Received Sept 19, 2015; Received in revised form Dec 23, 2015; Accepted February 2, 2016; Available online How to Cite This Article: Bhujangrao, K.H. (2016. Design and Development of Prototype Cylindrical Parabolic Solar Collector for Water Heating Application. International Journal of Renewable Energy Development, 5(1, 49-55 http://dx.doi.org/10.14710/ijred.5.1.49-55 

  19. Growth of winter flounder (Pseudopleuronectes americanus) and smooth flounder (Liopsetta putnami) in heated and unheated water

    Energy Technology Data Exchange (ETDEWEB)

    Hoornbeek, F.K. (Univ. of New Hampshire, Durham); Sawyer, P.J.; Sawyer, E.S.

    1982-07-01

    O-group and I-group winter (Pseudopleuronetes americanus) and smooth (Liopsetta putnami) flounder were reared at the Jackson Estuarine Laboratory, Durham, NH, U.S.A., between November 1975 and June 1976. Both species gained weight approximately three times more rapidly in heated than in unheated water. In unheated water the smallest winter flounder gained, on average, 116% of their body weight per month. Larger O-group winter flounder increased body weight by 55% per month, while comparably sized female and male smooth flounder gained 52% and 28% per month, respectively. I-group female smooth flounder gained 9.5% and male smooth flounder 8.5% per month in heated water. In unheated water increases were 13%, 22%, and 14% per month for O-group winter, female smooth and male smooth flounder, respectively. I-group winter flounder in unheated water gained weight twice as rapidly (9.5%) per month) as I-group female and male smooth flounder (4.0% and 4.5% per month, respectively). Fish were fed a moist diet at a level of 10% of their body weight per day. Conversions (dry weight of food/wet weight of fish) ranged from 1:1 for O-group winter flounder in heated water to 27:1 for I-group smooth flounder in unheated water. Disease was a major cause of mortality. Vibrio anguillarum was confirmed as a pathogen; myxobacteria, and the protozoan parasites Kudoa sp. and Nosema sp. were associated with losses.

  20. Summertime hot water comfort in houses[District heating optimization]; Varmvattenkomfort sommatid i smaahus

    Energy Technology Data Exchange (ETDEWEB)

    Persson, Tommy [Lund Inst. of Technology (Sweden). Dept. of Heat and Power Engineering

    2002-07-01

    Problems with low domestic hot water temperature summertime in district heating systems in low heat density areas is studied. The study is based on dynamic simulation of a part of a district heating system. A part of the DH system in Malmoe, owned by Sydkraft Vaerme Malmoe AB, serves as source of inspiration for the computer model. The system in Malmoe is used as a reference system in the investigations. A number of different system configurations are regarded. For example, the influence of the following is investigated: the placing of thermostatic valves in the system, length of pipes, type of domestic hot water controller in the DH substations, degree of insulation of the pipes, pipe dimensions, supply temperature at the production site and also domestic hot water use. The different system configurations are optimized with respect to heat losses under the condition that an acceptable domestic hot water comfort must be secured. How to construct the domestic hot water controllers in order to achieve the best system performance is also studied in the report. The calculations show that regardless of if a thermostatic valve is installed only in the periphery of the DH system or in all DH substations there is an optimum set point at which the heat losses from the system is minimized. For all the system configurations studied in this project an acceptable domestic hot water temperature is secured at the optimum set point. It appears that under operation conditions where a good domestic hot water temperature cannot be attained in large parts of the system the characteristics of the DH substations will lead to high return temperatures. The high return temperatures lead to an increase in heat losses and such operation conditions cannot coincide with an optimum set point regarding heat losses from the system. For both alternatives regarding the location of the thermostatic valve(s) the optimum set point is reduced as the length of the distribution pipes is increased. In the

  1. Solar heating and hot water system installed at office building, One Solar Place, Dallas, Texas. Final report

    Energy Technology Data Exchange (ETDEWEB)

    1980-06-01

    This document is the Final Report of the Solar Energy System Installed at the First Solar Heated Office Building, One Solar Place, Dallas, Texas. The Solar System was designed to provide 87 percent of the space heating needs, 100 percent of the potable hot water needs and is sized for future absorption cooling. The collection subsystem consists of 28 Solargenics, series 76, flat plate collectors with a total area of 1596 square feet. The solar loop circulates an ethylene glycol-water solution through the collectors into a hot water system heat exchanger. The hot water storage subsystem consists of a heat exchanger, two 2300 gallon concrete hot water storage tanks with built in heat exchangers and a back-up electric boiler. The domestic hot water subsystem sends hot water to the 10,200 square feet floor area office building hot water fixtures. The building cold water system provides make-up to the solar loop, the heating loop, and the hot water concrete storage tanks. The design, construction, cost analysis, operation and maintenance of the solar system are described. The system became operational July 11, 1979.

  2. Water Phase Change Heat Exchanger System Level Analysis for Low Lunar Orbit

    Science.gov (United States)

    Navarro, Moses; Ungar, Eugene; Sheth, Rubik; Hansen, Scott

    2016-01-01

    In low Lunar orbit (LLO) the thermal environment is cyclic - extremely cold in the eclipse and as warm as room temperature near the subsolar point. Phase change material heat exchangers (PCHXs) are the best option for long term missions in these environments. The Orion spacecraft will use a n-pentadecane wax PCHX for its envisioned mission to LLO. Using water as a PCM material is attractive because its higher heat of fusion and greater density result in a lighter, more compact PCHX. To assess the use of a water PCHX for a human spacecraft in a circular LLO, a system level analysis was performed for the Orion spacecraft. Three cases were evaluated: 1) A one-to-one replacement of the wax PCHX on the internal thermal control loop with a water PCHX (including the appropriate control modifications), 2) reducing the radiator return setpoint temperature below Orion's value to enhance PCHX freezing, and 3) placing the water PCM on the external loop. The model showed that the water PCHX could not be used as a drop-in replacement for the wax PCHX. It did not freeze fully during the eclipse owing to its low freezing point. To obtain equivalent performance, 40% more radiator area than the Orion baseline was required. The study shows that, although water PCHXs are attractive at a component level, system level effects mean that they are not the best choice for LLO.

  3. Experimental Research on Water Boiling Heat Transfer on Horizontal Copper Rod Surface at Sub-Atmospheric Pressure

    Directory of Open Access Journals (Sweden)

    Li-Hua Yu

    2015-09-01

    Full Text Available In recent years, water (R718 as a kind of natural refrigerant—which is environmentally-friendly, safe and cheap—has been reconsidered by scholars. The systems of using water as the refrigerant, such as water vapor compression refrigeration and heat pump systems run at sub-atmospheric pressure. So, the research on water boiling heat transfer at sub-atmospheric pressure has been an important issue. There are many research papers on the evaporation of water, but there is a lack of data on the characteristics at sub-atmospheric pressures, especially lower than 3 kPa (the saturation temperature is 24 °C. In this paper, the experimental research on water boiling heat transfer on a horizontal copper rod surface at 1.8–3.3 kPa is presented. Regression equations of the boiling heat transfer coefficient are obtained based on the experimental data, which are convenient for practical application.

  4. Effects of radiation on convection heat transfer of Cu-water nanofluid past a moving wedge

    Directory of Open Access Journals (Sweden)

    Salama Faiza A.

    2016-01-01

    Full Text Available Heat transfer characteristics of a two-dimensional steady hydrodynamic flow of water-based copper(Cu nanofluid over a moving wedge, taking into account the effects of thermal radiation, have been investigated numerically. The Rosseland approximation is used to describe the radiative heat flux in the energy equation. The governing fundamental equations are first transformed into a system of ordinary differential equations and solved numerically by using the fourth-order Runge-kutta method with shooting technique. A comparison with previously published work has been carried out and the results are found to be in good agreement. The existence of unique and dual solutions for self-similar equations of the flow and heat transfer are analyzed numerically. The results indicate that there is strong dependence of the thermal gradient at the surface of the wedge on both velocity ratio parameter and thermal radiation.

  5. Hot water preparation with heat pumps; Warmwasserbereitung mit Waermepumpe. Messungen an einer Anlage in Rorschacherberg

    Energy Technology Data Exchange (ETDEWEB)

    Mayer, H.; Gabathuler, H. R. [Gabathuler AG, Beratende Ingenieure, Diessenhofen (Switzerland); Baumgartner, Th. [Th. Baumgartner and Partner AG, Duebendorf (Switzerland)

    2007-07-15

    This final report for the Swiss Federal Office of Energy (SFOE) presents the results of measurements made on an installation in Rorschacherberg, Switzerland. The paper examines the results obtained as a result of implementing recommendations for designing domestic hot water heating systems using heat pumps. These were published in the STASCH project on standard circuit diagrams for small-scale heat pump plants. The effectiveness of these recommendations was investigated in this project. Furthermore, optimum hydraulic circuits and control procedures were developed based on measurements made on the experimental plant in Rorschacherberg. The installation examined is described and commented on. Six configuration variants conforming to the STASCH concept are examined and operational aspects are commented on. Finally, recommendations on temperatures and operational modi are made.

  6. Sequential and selective localized optical heating in water via on-chip dielectric nanopatterning.

    Science.gov (United States)

    Morsy, Ahmed M; Biswas, Roshni; Povinelli, Michelle L

    2017-07-24

    We study the use of nanopatterned silicon membranes to obtain optically-induced heating in water. We show that by varying the detuning between an absorptive optical resonance of the patterned membrane and an illumination laser, both the magnitude and response time of the temperature rise can be controlled. This allows for either sequential or selective heating of different patterned areas on chip. We obtain a steady-state temperature of approximately 100 °C for a 805.5nm CW laser power density of 66 µW/μm(2) and observe microbubble formation. The ability to spatially and temporally control temperature on the microscale should enable the study of heat-induced effects in a variety of chemical and biological lab-on-chip applications.

  7. Heat transfer coefficient distribution over the inconel plate cooled from high temperature by the array of water jets

    Science.gov (United States)

    Malinowski, Z.; Telejko, T.; Cebo-Rudnicka, A.; Szajding, A.; Rywotycki, M.; Hadała, B.

    2016-09-01

    The industrial rolling mills are equipped with systems for controlled water cooling of hot steel products. A cooling rate affects the final mechanical properties of steel which are strongly dependent on microstructure evolution processes. In case of water jets cooling the heat transfer boundary condition can be defined by the heat transfer coefficient. In the present study one and three dimensional heat conduction models have been employed in the inverse solution to heat transfer coefficient. The inconel plate has been heated to about 900oC and then cooled by one, two and six water jets. The plate temperature has been measured by 30 thermocouples. The heat transfer coefficient distributions at plate surface have been determined in time of cooling.

  8. Characteristic of local boiling heat transfer of ammonia and ammonia / water binary mixture on the plate type evaporator

    Science.gov (United States)

    Okamoto, Akio; Arima, Hirofumi; Ikegami, Yasuyuki

    2011-08-01

    Power generation using small temperature difference such as ocean thermal energy conversion (OTEC) and discharged thermal energy conversion (DTEC) is expected to be the countermeasures against global warming problem. As ammonia and ammonia/water are used in evaporators for OTEC and DTEC as working fluids, the research of their local boiling heat transfer is important for improvement of the power generation efficiency. Measurements of local boiling heat transfer coefficients were performed for ammonia /water mixture ( z = 0.9-1) on a vertical flat plate heat exchanger in a range of mass flux (7.5-15 kg/m2 s), heat flux (15-23 kW/m2), and pressure (0.7-0.9 MPa). The result shows that in the case of ammonia /water mixture, the local heat transfer coefficients increase with an increase of mass flux and composition of ammonia, and decrease with an increase of heat flux.

  9. Influence of mashed potato dielectric properties and circulating water electric conductivity on radio frequency heating at 27 MHz.

    Science.gov (United States)

    Wang, Jian; Olsen, Robert G; Tang, Juming; Tang, Zhongwei

    2008-01-01

    Experiments and computer simulations were conducted to systematically investigate the influence of mashed potato dielectric properties and circulating water electric conductivity on electromagnetic field distribution, heating rate, and heating pattern in packaged food during radio frequency (RF) heating processes in a 6 kW, 27 MHz laboratory scale RF heating system. Both experimental and simulation results indicated that for the selected food (mashed potato) in this study, the heating rate decreased with an increase of electric conductivity of circulating water and food salt content. Simplified analytical calculations were carried out to verify the simulation results, which further indicated that the electric field distribution in the mashed potato samples was also influenced by their dielectric properties and the electric conductivity of the surrounding circulating water. Knowing the influence of water electric conductivity and mashed potato dielectric properties on the heating rate and heating pattern is helpful in optimizing the radio frequency heating process by properly adjusting these factors. The results demonstrate that computer simulation has the ability to demonstrate influence on RF heat pattern caused by the variation of material physical properties and the potential to aid the improvement on construction and modification of RF heating systems.

  10. Heat and water rate transfer processes in the human respiratory tract at various altitudes.

    Science.gov (United States)

    Kandjov, I M

    2001-02-01

    The process of the respiratory air conditioning as a process of heat and mass exchange at the interface inspired air-airways surface was studied. Using a model of airways (Olson et al., 1970) where the segments of the respiratory tract are like cylinders with a fixed length and diameter, the corresponding heat transfer equations, in the paper are founded basic rate exchange parameters-convective heat transfer coefficient h(c)(W m(-2) degrees C(-1)) and evaporative heat transfer coefficient h(e)(W m(-2)hPa(-1)). The rate transfer parameters assumed as sources with known heat power are connected to airflow rate in different airways segments. Relationships expressing warming rate of inspired air due to convection, warming rate of inspired air due to evaporation, water diffused in the inspired air from the airways wall, i.e. a system of air conditioning parameters, was composed. The altitude dynamics of the relations is studied. Every rate conditioning parameter is an increasing function of altitude. The process of diffusion in the peripheral bronchial generations as a basic transfer process is analysed. The following phenomenon is in effect: the diffusion coefficient increases with altitude and causes a compensation of simultaneous decreasing of O(2)and CO(2)densities in atmospheric air. Due to this compensation, the diffusion in the peripheral generations with altitude is approximately constant. The elements of the human anatomy optimality as well as the established dynamics are discussed and assumed. The square form of the airways after the trachea expressed in terms of transfer supposes (in view of maximum contact surface), that a maximum heat and water exchange is achieved, i.e. high degree of air condition at fixed environmental parameters and respiration regime.

  11. Seasonal Spatial Patterns of Surface Water Temperature, Surface Heat Fluxes and Meteorological Forcing Over Lake Geneva

    Science.gov (United States)

    Irani Rahaghi, A.; Lemmin, U.; Bouffard, D.; Riffler, M.; Wunderle, S.; Barry, D. A.

    2015-12-01

    In many lakes, surface heat flux (SHF) is the most important component controlling the lake's energy content. Accurate methods for the determination of SHF are valuable for water management, and for use in hydrological and meteorological models. Large lakes, not surprisingly, are subject to spatially and temporally varying meteorological conditions, and hence SHF. Here, we report on an investigation for estimating the SHF of a large European lake, Lake Geneva. We evaluated several bulk formulas to estimate Lake Geneva's SHF based on different data sources. A total of 64 different surface heat flux models were realized using existing representations for different heat flux components. Data sources to run the models included meteorological data (from an operational numerical weather prediction model, COSMO-2) and lake surface water temperature (LSWT, from satellite imagery). Models were calibrated at two points in the lake for which regular depth profiles of temperature are available, and which enabled computation of the total heat content variation. The latter, computed for 03.2008-12.2012, was the metric used to rank the different models. The best calibrated model was then selected to calculate the spatial distribution of SHF. Analysis of the model results shows that evaporative and convective heat fluxes are the dominant terms controlling the spatial pattern of SHF. The former is significant in all seasons while the latter plays a role only in fall and winter. Meteorological observations illustrate that wind-sheltering, and to some extent relative humidity variability, are the main reasons for the observed large-scale spatial variability. In addition, both modeling and satellite observations indicate that, on average, the eastern part of the lake is warmer than the western part, with a greater temperature contrast in spring and summer than in fall and winter whereas the SHF spatial splitting is stronger in fall and winter. This is mainly due to negative heat flux

  12. Evaluation of the heat flux on the bottom boundary in shallow waters

    Science.gov (United States)

    Debolskaya, Elena; Ivanov, Alexandre

    2014-05-01

    It is known that in solving the problem of heat transfer in the natural reservoirs in the absence of apparent heat sources the zero heat flux is defined on the bottom boundary. In this work we estimate this assumption, in dependence on external factors affecting the process of heat transfer, and morphometric parameters of the reservoir. We consider a water reservoir of the finite, gradually variable in space depth and with an open surface and assume that both shallow and deep zones are subjected to the same external influences (homogeneous periodic heat flux at the boundary with the atmosphere, a uniform velocity field). Under such conditions, the entire body of water can be considered as a collection of liquid column, and to calculate the temperature distribution it is possible to apply the one-dimensional heat conduction equation for each column with initial uniform temperature distribution in the depth and periodic boundary conditions at the upper boundary. If we accept the assumption about independence of thermal diffusivity from the depth, we can get the solution of these equation and boundary condition and estimate the depth, where the boundary condition at the bottom will not influence on the temperature distribution. In the absence of fully developed turbulence (without the effects of wind and currents) at the value of the molecular viscosity of water and daily temperature variations, we obtain H = 0.38m. At seasonal variations H = 7.3 m. The main reason for turbulent mixing in lakes and natural reservoirs is wind action (in the absence of significant flows). To estimate the coefficient of turbulent exchange in this case we use the formula based on the formula of Prandtl-Obukhov and Ekman's approximate solutions for wind currents. At low density stratification the vertical gradient of density can be neglected. Obviously, the estimates made at the maximum coefficient of the turbulent viscosity K0 (the coefficient of molecular viscosity is neglected since it

  13. Carbonation of low heat portland cement paste procured in water for different time

    Institute of Scientific and Technical Information of China (English)

    Deping Chen; Etsuo Sakai; Masaki Daimon; Yoko Ohba

    2007-01-01

    The carbonation technique was applied to accelerate the hydration of low heat portland cement (LHC). Before carbonation, the demoulded pastes were precured in water for 0, 2, 7, and 21 d, respectively. The results show that procuring time in water strongly influences the carbonation process. The phenolphthalein test indicates that the paste precured in water for a shorter time is more quickly carbonated than that for a longer time. The content of calcium hydroxide increases with increasing the procuring time in water, whereas, the amount of absorbed carbon dioxide changes contrarily. Scanning electron microscope (SEM) observation shows that portlandite always fills up big air bubbles in the paste during precuring in water, and the mercury intrusion porosimetry (MIP) results show that there are less large capillary pores in the paste precured in water for a longer time. It is found that the paste without precuring in water has more carbon dioxide absorption during curing in carbon dioxide atmosphere, and its total pore volume decreases remarkably with an increase in the carbonation time than that precured in water. X-ray diffraction (XRD) and Brunauer-Emmett-Teller (BET) surface area analyses indicate that the carbonate products are vaterite and calcite; CxSHy,, formed from carbonation has low BET surface area in comparison with that of C-S-H formed from curing in water.

  14. River temperature processes under contrasting riparian land cover: linking microclimate, heat exchange and water thermal dynamics

    Science.gov (United States)

    Hannah, D. M.; Kantola, K.; Malcolm, I.

    2012-12-01

    River temperature influences strongly growth and survival in salmonid fish, which are often the target of river management strategies. Temperature is controlled by transfers of heat and water to/ from the river system, with land and water management modifying exchanges and consequently thermal regime. In the UK, fisheries managers are promoting riparian forest planting as a climate change adaption measure to reduce water temperature extremes. However, scientific understanding lags behind management and policy needs. Specifically, there is an urgent requirement to determine planting strategies that maximise expected benefits of riparian forest in terms of reduction in maximum water temperature. Scientific knowledge is necessary to underpin conceptual and deterministic models to inform management. To address this research gap, this paper analyses high resolution (15 minute) hydrometeorological data collected over a calendar year in the western Scottish Highlands (Loch Ard) to understand the controls and processes determining river temperature dynamics under open moorland (control), semi-natural woodland and commercial forest. The research programme aims: (1) to characterise spatial and temporal variability in riparian microclimate and stream water temperature regime across forest treatments; (2) to identify the hydrological, climatological and site-specific factors affecting stream temperature; (3) to estimate the energy balance at sites representative of each forest treatment and, thus, yield physical process understanding about dominant heat exchanges driving thermal variability; and (4) to use 1-3 to predict stream temperature sensitivity under different forestry and hydroclimatological scenarios. Results indicated that inter-treatment differences in mean and maximum daily water column temperature were ordered open > semi-natural > commercial during summer, but semi-natural > commercial > open during winter. Minimum water temperature was ordered commercial > semi

  15. Analysis of the ability of water resources to reduce the urban heat island in the Tokyo megalopolis.

    Science.gov (United States)

    Nakayama, Tadanobu; Hashimoto, Shizuka

    2011-01-01

    Simulation procedure integrated with multi-scale in horizontally regional-urban-point levels and in vertically atmosphere-surface-unsaturated-saturated layers, was newly developed in order to predict the effect of urban geometry and anthropogenic exhaustion on the hydrothermal changes in the atmospheric/land and the interfacial areas of the Japanese megalopolis. The simulated results suggested that the latent heat flux in new water-holding pavement (consisting of porous asphalt and water-holding filler made of steel by-products based on silica compound) has a strong impact on hydrologic cycle and cooling temperature in comparison with the observed heat budget. We evaluated the relationship between the effect of groundwater use as a heat sink to tackle the heat island and the effect of infiltration on the water cycle in the urban area. The result indicates that effective management of water resources would be powerful for ameliorating the heat island and recovering sound hydrologic cycle there.

  16. Liquid heat capacity of the solvent system (piperazine + 2-amino-2-methyl-l-propanol + water)

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Y.-R. [R and D Center for Membrane Technology and Department of Chemical Engineering, Chung Yuan Christian University, Chung Li 32023, Taiwan (China); Caparanga, Alvin R.; Soriano, Allan N. [R and D Center for Membrane Technology and Department of Chemical Engineering, Chung Yuan Christian University, Chung Li 32023, Taiwan (China); School of Chemical Engineering and Chemistry, Mapua Institute of Technology, Intramuros, Manila 1002 (Philippines); Li, M.-H., E-mail: mhli@cycu.edu.t [R and D Center for Membrane Technology and Department of Chemical Engineering, Chung Yuan Christian University, Chung Li 32023, Taiwan (China)

    2010-04-15

    This report presents a new set of heat capacity data for the system piperazine left brace(PZ) + 2-amino-2-methyl-1-propanol (AMP) + water (H{sub 2}O)right brace, measured using the differential scanning calorimetry technique, over the temperature range 303.2 K to 353.2 K and at fourteen (14) different concentrations in which the water mole fractions, x{sub 3}'s, were fixed at 0.60, 0.70, 0.80, and 0.90. Heat capacity for the binary system left bracePZ (1) + AMP (2)right brace at x{sub 1} = 0.05, 0.10, 0.15, and 0.20 were, likewise, measured to generate parameters necessary in the Redlich-Kister-type model, which was used to estimate excess molar heat capacities. Such estimates were then used to predict the values of the molar heat capacity at the corresponding sets of temperature and concentration. The predicted values were subsequently compared against the measured values and the results are satisfactory.

  17. Critical heat flux prediction for water boiling in vertical tubes of a steam generator

    Energy Technology Data Exchange (ETDEWEB)

    Payan-Rodriguez, L.A.; Gallegos-Munoz [Departmet of Mechanical Engineering, University of Guanajuato, Av. Tampico No. 912 Salamanca (Mexico); Porras-Loaiza, G.L. [Institute for Electrical Researches, Av. Reforma No. 113, Temixco (Mexico); Picon-Nunez [Institute for Scientific Research, University of Guanajuato, Lascurain de Retana No. 5, Guanajuato (Mexico)

    2005-02-01

    This paper presents a methodology for the prediction of the critical heat flux (CHF) for the boiling of water in vertical tubes operating under typical conditions found in steam generators. At the furnace, the water flows through long vertical tubes under an axially non-uniform heat flux and with relatively low mass fluxes. This fact causes that the recent theories and correlations, which have been developed for conditions typically found in nuclear reactors, cannot be directly applied for the prediction of the CHF in the furnace tubes. In this context, the mechanistic theories focused into the CHF prediction have proved their usefulness to predict CHF avoiding the use of correlations and experimental constants. Hence, in order to assist the CHF problem in steam generators, the sublayer dryout theory, initially formulated for CHF in vertical tubes uniformly heated, is extended by combining it with the shape factor method (F-factor), to account for the effects of the axially non-uniform heat flux distribution. The critical wall temperature (CWT) of the tubes is calculated from CHF data. The reliability of the modified theory for the CHF prediction is tested by comparing CWT results against measured data from a steam generator of a power plant. Good consistency and approximation is found between predicted and measured data. (authors)

  18. Development and application of engineering-scale solar water heater system assisted by heat pump

    Energy Technology Data Exchange (ETDEWEB)

    Gao Xiufeng; Feng Shiyu; Hu Wei; Zheng Feifei [Xi' an Jiaotong Univ., Xi' an (China); Wang Huiyu; Luo Cong [Yangzhou Sunleada Co, Ltd, Yangzhou (China); Wang Jianguo; Fan Guiyou [TongLing Real Estate Co. Ltd, TongLing (China)

    2008-07-01

    An engineering-scale solar water heater system assisted by heat pump was developed based on a modularized structure. The subunits of modularized system include vacuum solar energy collectors, air source heat pump, heat storage and supplying system and control panel. All devices could be controlled and monitored centrally. Energy source of this system was composed of solar energy (70%), air thermal energy (20%) and electric power (10%). The system has advantages of high average annual comprehensive energy efficiency and elementary energy utilization efficiency. The product can be employed in central heat water supplying project with a capacity of more than 6 ton, in such facilities as residential districts, hotels, restaurants, dormitories, bathing centers and so on. The economical efficiency is better as the scale is bigger. The project has been supported by innovation funds of Science and Technology of Chinese Ministry of Science and Technology (MOST), being applied in a residential district successfully as a demonstration project of renewable and new energy by Chinese Ministry of Construction. (orig.)

  19. Experimental study of water droplets on over-heated nano/microstructured zirconium surfaces

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Seol Ha [Division of Advanced Nuclear Engineering, POSTECH, Pohang 790-784 (Korea, Republic of); Ahn, Ho Seon [Division of Mechanical System Engineering, Incheon National University, 406-772 (Korea, Republic of); Kim, Joonwon [Department of Mechanical Engineering, POSTECH, Pohang 790-784 (Korea, Republic of); Kim, Moo Hwan [Division of Advanced Nuclear Engineering, POSTECH, Pohang 790-784 (Korea, Republic of); Park, Hyun Sun, E-mail: hejsunny@postech.ac.kr [Division of Advanced Nuclear Engineering, POSTECH, Pohang 790-784 (Korea, Republic of)

    2014-10-15

    Highlights: • Heat transfer performance of a droplet on a modified zirconium surface is evaluated. • Modified (nano/micro-) surfaces enhanced heat transfer rate and Leidenfrost point. • A highly wettable condition of the modified surface contributes the enhancement. • Nano-scaled modification indicates the higher performance of droplet cooling. • Investigation via visualization of the droplet support the heat transfer experimental data. - Abstract: In this study, we observed the behavior of water droplets near the Leidenfrost point (LFP) on zirconium alloy surfaces with anodizing treatment and investigated the droplet cooling performance. The anodized zirconium surface, which consists of bundles of nanotubes (∼10–100 nm) or micro-mountain-like structures, improved the wetting characteristics of the surface. A deionized water droplet (6 μL) was dropped onto test surfaces heated to temperatures ranging from 250 °C to the LFP. The droplet dynamics were investigated through high-speed visualization, and the cooling performance was discussed in terms of the droplet evaporation time. The modified surface provided vigorous, intensive nucleate boiling in comparison with a clean, bare surface. Additionally, we observed that the structured surface had a delayed LFP due to the high wetting condition induced by strong capillary wicking forces on the structured surface.

  20. Investigation of effects of chemical dosing on fuel consumption in central heating systems with superheated water

    Energy Technology Data Exchange (ETDEWEB)

    Bilen, Kemal [Kirikkale University, Engineering Faculty, Mechanical Engineering Department, Kirikkale (Turkey); email: kemal.bilen92@gmail.com

    2011-07-01

    In Turkey, a significant percentage of energy is consumed by buildings and heating accounts for most of it. These is therefore a need to increase the efficiency of such systems. As a regional heating option, central heating systems with superheated water are preferred and chemical dosing of these systems has become prevalent in recent years. This study analyses the energy and exergy of a superheated water, central heating system operated on natural gas, on a university campus with a population of 15000 people, and investigates the effect of chemical dosing on their efficiencies. The study results showed that the average energy and exergy efficiencies of the system were 92.07% and 62.45%, respectively. The results also demonstrated that there was a 5.21% and 2.74% increase in hourly gas consumption when the dosing concentration was changed from 5 ppm to 101 ppm and 50 ppm to 101 ppm, respectively. It was concluded that for lower fuel consumption, chemical dosing should be avoided.

  1. Flow Boiling Heat Transfer Enhancement by Using ZnO-Water Nanofluids

    Directory of Open Access Journals (Sweden)

    Om Shankar Prajapati

    2014-01-01

    Full Text Available Nanofluids are liquid suspensions containing nanoparticles that are smaller than 100 nm. There is an increased interest in nanofluids as thermal conductivity of nanofluids is significantly higher than that of the base liquids. ZnO-water nanofluids with volume concentration of ZnO particles varying from 0.0001 to 0.1% were prepared using ultrasonic vibration mixer. Thermal conductivity of the ZnO-water fluids was investigated for different sonication time using thermal property analyzer (KD2 Pro. Thermal conductivity of nanofluids for a given concentration of nanoparticle varies with sonication time. Heat transfer coefficient and pressure drop in an annular test section with variable pressure (1–2.5 bar and heat flux (0–400 kW/m2 at constant mass flux of 400 kg/m2s were studied for samples having maximum thermal conductivity. Surface roughness of the heating rod was also measured before and after the experimentation. The study shows that heat transfer coefficient increases beyond the base fluid with pressure and concentration of ZnO.

  2. Heat transfer in packed beds: experimental evaluation of one-phase water flow

    Directory of Open Access Journals (Sweden)

    J. C. Thoméo

    2004-01-01

    Full Text Available Experimental heat transfer studies were carried out in 50.8 mm diameter packed beds of glass beads percolated by water and heated from the wall. The tube-to-particle diameter ratio (D/d p ranged from 1.72 to 13.7 and the water flow rate from 1.1 to 9.9 l/min. Bed heights ranged from 100 mm to 700 mm. The radial temperature was measured above the bed surface by five aligned sheathed thermocouples. Variations in angular temperature were observed, independent of both radial position and particle diameter. Results of repeated tests with the same packing and with repacking did not differ statistically. The radial temperature profile at the bed entrance, measured by a ring-shaped sensor, was uniform except very close to the tube wall.

  3. Heated Debates: Hot-Water Immersion or Ice Packs as First Aid for Cnidarian Envenomations?

    Science.gov (United States)

    Wilcox, Christie L; Yanagihara, Angel A

    2016-04-01

    Cnidarian envenomations are an important public health problem, responsible for more deaths than shark attacks annually. For this reason, optimization of first-aid care is essential. According to the published literature, cnidarian venoms and toxins are heat labile at temperatures safe for human application, which supports the use of hot-water immersion of the sting area(s). However, ice packs are often recommended and used by emergency personnel. After conducting a systematic review of the evidence for the use of heat or ice in the treatment of cnidarian envenomations, we conclude that the majority of studies to date support the use of hot-water immersion for pain relief and improved health outcomes.

  4. Investment and Economy Analysis of Water-Source Heat Pump System in Chongqing, China

    Directory of Open Access Journals (Sweden)

    Yong Ding

    2013-01-01

    Full Text Available In China, the application of renewable energy witnesses rapid development. In the near future, a lot of demonstration projects will be built and thus it is urgent to know the economics of renewable energy building application technologies. Based on the renewable energy demonstration projects in Chongqing city, the author discussed the economy issue of water-source heat pump system (WSHPs in order to provide suggestions for the application projects. According to the design information of demonstration projects, the average incremental investment, allowance, and payback period are calculated in this paper. Comparing WSHPs with traditional heating, ventilation, and air conditioning (HVAC system, the saved energy of WSHPs is estimated in the current paper. The author calculated the amount of saved energy in unit applied area and unit intake water. Besides, the economy and efficiency of WSHPs project is analyzed at the end of this paper.

  5. Enhancing water repellence and mechanical properties of antibacterialgelatin/Ce(lll) fiber by heat treatment

    Institute of Scientific and Technical Information of China (English)

    LIU Lin; WANG Shiqi; HUANG Yaqin; ZHOU Yating; TONG Yuanjian; CHEN Xiaonong

    2011-01-01

    The water repellence and mechanical properties of the gelatin/Ce(Ⅲ) fiber (GCe fiber) were improved by heat treatment,which was an easy and non-toxic method.The microscopic morphology,mechanical properties,antibacterial activity,and cell culture of the GCe fibers by heat treatment (HGCe fiber) were investigated.It was found that the water repellence and mechanical properties of the HGCe fibers increased significantly along with temperature increase.SEM observation showed that HGCe fibers had a fairly smooth surface and a compact structure.Detailed characterization revealed that the HGCe fibers exhibited similar antibacterial activity with the GCe fibers against Staphylococcus aureus.In addition,the results of cell culture by morphological assessment and methylthiazolyl tetrazolium assay (MTT assay)indicated the good biocompatibility of GCe fibers.Therefore,the HGCe fibers could be a promising candidate biomaterial for biomedicine applications.

  6. Effect of heat treatments on 8090 AlLi alloy pitting susceptibility in sea water

    Energy Technology Data Exchange (ETDEWEB)

    Beccaria, A.M. [CNR, Genova (Italy). Istituto per la Corrosion Marina dei Metalli; Traverso, P. [CNR, Genova (Italy). Istituto per la Corrosion Marina dei Metalli

    1996-05-01

    The pitting susceptibility of 8090 Al-Li alloy in sea water, after different heat treatments, was investigated. Free corrosion and electrochemical tests were carried out at 25 C, in quiescent sea water at pH=8.2 and dissolved oxygen =6.5 ppm. The microstructure was examined by metallographic microscopy and by X-Ray microdiffractometry, while the corrosion layer was characterized by chemical methods and by Infrared and X-ray photoelectron spectroscopies. The following was observed: . aging treatments lead to a non homogeneous microstructure which increases the average corrosion rate as well as pitting susceptibility; . heat treatments do not affect the average passive film composition; . in all examined states, Al-Li alloy 8090 is subject to localized corrosion which takes place preferentially at the grain boundaries. (orig.)

  7. Heated Debates: Hot-Water Immersion or Ice Packs as First Aid for Cnidarian Envenomations?

    Directory of Open Access Journals (Sweden)

    Christie L. Wilcox

    2016-04-01

    Full Text Available Cnidarian envenomations are an important public health problem, responsible for more deaths than shark attacks annually. For this reason, optimization of first-aid care is essential. According to the published literature, cnidarian venoms and toxins are heat labile at temperatures safe for human application, which supports the use of hot-water immersion of the sting area(s. However, ice packs are often recommended and used by emergency personnel. After conducting a systematic review of the evidence for the use of heat or ice in the treatment of cnidarian envenomations, we conclude that the majority of studies to date support the use of hot-water immersion for pain relief and improved health outcomes.

  8. Movement and evaporation of water droplets under conditions typical for heat-exchange chambers of contact water heaters

    Science.gov (United States)

    Volkov, R. S.; Kuznetsov, G. V.; Strizhak, P. A.

    2016-09-01

    The macroscopic regularities and integrated characteristics of the motion and evaporation of sprayed water droplets in the field of high-temperature (1100 K) combustion products under the conditions typical for water heaters of contact type (economizers) were studied using a cross-correlation complex working on the basis of panoramic optical methods (particle image velocimetry, particle tracking velocimetry, shadow photography) and high-speed (105 fps) Phantom video cameras. High-speed video recording devices with specialized software were used for continuously monitoring the motion and evaporation of droplets. Titanium dioxide nanopowder tracer particles were introduced to determine the rate of high-temperature gases. The characteristic distances covered by water droplets before their full retardation in the counter-flow of high-temperature combustion products were determined. The integrated dependences were obtained, and the main characteristics of evaporation were determined, which allow one to predict the intensity of the phase transformations of droplets (with sizes of 0.05-0.5 mm) and the distances covered by them before they completely turn in the opposite direction under the conditions corresponding to the heat-exchange chambers of contact water heaters: the vapor-droplet rate 1-5 m/s, gas flow rate 0.5-2 m/s, and gas temperature ~1100 K. Approximating expressions were derived to predict the characteristics of the processes. The performance of the economizers under study can be significantly increased by using the obtained experimental dependences, the corresponding approximating expressions, and the resulting conclusions. Conditions were determined under which the influence of phase transformations on retardation exceeds the contribution of the counter-motion and active retardation and evaporation of water droplets occur in the heat-exchange chambers of contact water heaters of typical sizes.

  9. Two-dimensional modeling of water and heat fluxes in green roof substrates

    Science.gov (United States)

    Suarez, F. I.; Sandoval, V. P.

    2016-12-01

    Due to public concern towards sustainable development, greenhouse gas emissions and energy efficiency, green roofs have become popular in the last years. Green roofs integrate vegetation into infrastructures to reach additional benefits that minimize negative impacts of the urbanization. A properly designed green roof can reduce environmental pollution, noise levels, energetic requirements or surface runoff. The correct performance of green roofs depends on site-specific conditions and on each component of the roof. The substrate and the vegetation layers strongly influence water and heat fluxes on a green roof. The substrate is an artificial media that has an improved performance compared to natural soils as it provides critical resources for vegetation survival: water, nutrients, and a growing media. Hence, it is important to study the effects of substrate properties on green roof performance. The objective of this work is to investigate how the thermal and hydraulic properties affect the behavior of a green roof through numerical modeling. The substrates that were investigated are composed by: crushed bricks and organic soil (S1); peat with perlite (S2); crushed bricks (S3); mineral soil with tree leaves (S4); and a mixture of topsoil and mineral soil (S5). The numerical model utilizes summer-arid meteorological information to evaluate the performance of each substrate. Results show that the area below the water retention curve helps to define the substrate that retains more water. In addition, the non-linearity of the water retention curve can increment the water needed to irrigate the roof. The heat propagation through the roof depends strongly on the hydraulic behavior, meaning that a combination of a substrate with low thermal conductivity and more porosity can reduce the heat fluxes across the roof. Therefore, it can minimize the energy consumed of an air-conditioner system.

  10. Effect of Internal Heat Recovery in Ammonia-Water Absorption Cooling Cycles: Exergy and Structural Analysis

    Directory of Open Access Journals (Sweden)

    Miquel Nogués

    2009-03-01

    Full Text Available First and second law analysis have been conducted for three low temperature driven ammonia-water absorption cooling cycles with increasing internal heat recovery. Based on the results of exergy analysis the structural analysis has been achieved. The obtained Coefficients of Structural Bonds (CSB consider how the irreversibility of the whole cycle is affected by a change in the irreversibility related to an efficiency improvement of a single component. Trends for the different configurations are similar, while quantitative differences among the main heat exchangers are considerable. The highest values of the CSB are found for the refrigerant heat exchanger. Also the evaporator, the condenser, the generator and the absorber show values higher than unity. The lowest CSB’s are obtained in the solution heat exchanger. In general, CSB’s decrease with increasing efficiency. That means that for very efficient heat exchangers, a further improvement looks less attractive. The dephlegmator is an exception as it shows a singularity of the CSB value due to its complex interactions with the other components. Once the CSB’s are obtained for the main components, they can be used in the structural method of the thermoeconomic optimisation. This method enables us to find the optimum design of a component in a straightforward calculation.

  11. System design package for SIMS prototype system 4, solar heating and domestic hot water

    Science.gov (United States)

    1978-01-01

    The system consisted of a modular designed prepackaged solar unit, containing solar collectors, a rock storage container, blowers, dampers, ducting, air-to-water heat exchanger, DHW preheat tank, piping, and system controls. The system was designed to be installed adjacent to a small single family dwelling. The description, performance specification, subsystem drawings, verification plan/procedure, and hazard analysis of the system were packaged for evaluation.

  12. Building America Case Study: Multifamily Central Heat Pump Water Heaters, Davis, California

    Energy Technology Data Exchange (ETDEWEB)

    2017-03-08

    Although heat pump water heaters (HPWHs) have gained significant attention in recent years as a high efficiency electric water heating solution for single family homes, central HPWHs for commercial or multi-family applications are not as well documented in terms of measured performance and cost effectiveness. To evaluate this technology, the Alliance for Residential Building Innovation team monitored the performance of a 10.5 ton central HPWH installed on a student apartment building at the West Village Zero Net Energy Community in Davis, California. Monitoring data collected over a 16-month period were then used to validate a TRNSYS simulation model. The TRNSYS model was then used to project performance in different climates using local electric rates. Results of the study indicate that after some initial commissioning issues, the HPWH operated reliably with an annual average efficiency of 2.12 (Coefficient of Performance). The observed efficiency was lower than the unit's rated efficiency, primarily due to the fact that the system rarely operated under steady-state conditions. Changes in the system configuration, storage tank sizing, and control settings would likely improve the observed field efficiency. Modeling results suggest significant energy savings relative to electric storage water heating systems (typical annual efficiencies around 0.90) providing for typical simple paybacks of six to ten years without any incentives. The economics versus gas water heating are currently much more challenging given the current low natural gas prices in much of the country. Increased market size for this technology would benefit cost effectiveness and spur greater technology innovation.

  13. Energy analysis of a central domestic hot water heating system equipped with condensing boilers

    Energy Technology Data Exchange (ETDEWEB)

    Cirillo, E.; Lazzarin, R.; Piccininni, F. (Bologna Univ. (Italy). Ist. di Fisica); Caliari, R. (Servizio Energia, Provincia Autonoma di Trento (IT))

    1990-01-01

    An experimental study was carried out on a central plant for the heating of domestic hot water for a block of 143 flats and 15 offices. The behaviour of the condensing boilers serving the plant was examined and the energy costs of recirculation and distribution were analysed. Since the losses due to recirculation are of the same order as the useful energy, the influence of the various parameters on the losses has been studied, and some methods of lowering them are proposed. (author).

  14. Building America Case Study: Multifamily Central Heat Pump Water Heaters, Davis, California

    Energy Technology Data Exchange (ETDEWEB)

    M. Hoeschele, E. Weitzel

    2017-03-01

    Although heat pump water heaters (HPWHs) have gained significant attention in recent years as a high efficiency electric water heating solution for single family homes, central HPWHs for commercial or multi-family applications are not as well documented in terms of measured performance and cost effectiveness. To evaluate this technology, the Alliance for Residential Building Innovation team monitored the performance of a 10.5 ton central HPWH installed on a student apartment building at the West Village Zero Net Energy Community in Davis, California. Monitoring data collected over a 16-month period were then used to validate a TRNSYS simulation model. The TRNSYS model was then used to project performance in different climates using local electric rates. Results of the study indicate that after some initial commissioning issues, the HPWH operated reliably with an annual average efficiency of 2.12 (Coefficient of Performance). The observed efficiency was lower than the unit's rated efficiency, primarily due to the fact that the system rarely operated under steady-state conditions. Changes in the system configuration, storage tank sizing, and control settings would likely improve the observed field efficiency. Modeling results suggest significant energy savings relative to electric storage water heating systems (typical annual efficiencies around 0.90) providing for typical simple paybacks of six to ten years without any incentives. The economics versus gas water heating are currently much more challenging given the current low natural gas prices in much of the country. Increased market size for this technology would benefit cost effectiveness and spur greater technology innovation.

  15. To the Problem of Designing Water Heating Solar Systems with Flat Collectors for Individual Dwellings

    Directory of Open Access Journals (Sweden)

    B. M. Khroustalev

    2011-01-01

    Full Text Available The variant of efficient combination of two renewable energy sources as a biogas system and a water heating solar system has been considered for power supply of individual dwellings. Criteria dependence has been suggested for determination of solar system power efficiency. Its legitimacy has been proved by an experiment. Power efficient solar system has been proposed with peculiar features of its designing and due account of energy flow distribution in technology of biogas production.

  16. System Design Package for SIMS Prototype System 3, Solar Heating and Domestic Hot Water

    Science.gov (United States)

    1978-01-01

    A collation of documents and drawings are presented that describe a prototype solar heating and hot water system using liquid flat plate collectors and a gas or electric furnace energy subsystem. The system was designed for installation into a single-family dwelling. The description, performance specification, subsystem drawings, verification plan/procedure, and hazard analysis of the system are packaged for evaluation of the system with information sufficient to assemble a similar system.

  17. Low Maintenance Water Treatment for Heating and Cooling Systems: Review of Technologies and Guidelines for Implementation

    Science.gov (United States)

    2007-09-01

    by oxidizing bio- cides. Also, the relatively new phosphonate, manganese/aminophosphonic acid ( MAPA ) has shown some promise as a copper corrosion...Headquarters, U.S. Army Corps of Engineers HVAC heating, ventilating, and air conditioning IWC International Water Conference MAPA manganese/aminophosphonic...aninophosphonic acid ( MAPA ) Y Y Mercaptobenzothiazole (MBT) N Y Molybdate Y N Nitrite N Y Orthophosphate Y N Phosphonocarboxylic acid (POCA) Y N

  18. Gelatinization and solubility of corn starch during heating in excess water: new insights.

    Science.gov (United States)

    Ratnayake, Wajira S; Jackson, David S

    2006-05-17

    Starch gelatinization is associated with the disruption of granular structure causing starch molecules to disperse in water. This study was designed to examine starch granules as they were heated in water, and their resulting morphological, structural, and solubility traits. The results indicate that starch gelatinization is a more complex process than the previously suggested order-to-disorder transition. The energy absorbed by the granules facilitates the rearrangement or formation of new bonds among molecules prior to the temperatures normally associated with the melting of amylopectin crystallites during gelatinization. It is also evident that amylose plays an important role during the initial stages of corn starch gelatinization.

  19. Temperature distribution of a hot water storage tank in a simulated solar heating and cooling system

    Science.gov (United States)

    Namkoong, D.

    1976-01-01

    A 2,300-liter hot water storage tank was studied under conditions simulating a solar heating and cooling system. The initial condition of the tank, ranging from 37 C at the bottom to 94 C at the top, represented a condition midway through the start-up period of the system. During the five-day test period, the water in the tank gradually rose in temperature but in a manner that diminished its temperature stratification. Stratification was found not to be an important factor in the operation of the particular solar system studied.

  20. Isolation of the etiological agent of primary amoebic meningoencephalitis from artificially heated waters

    Energy Technology Data Exchange (ETDEWEB)

    Stevens, A.R.; Tyndall, R.L.; Coutant, C.C.; Willaert, E.

    1977-12-01

    To determine whether artificial heating of water by power plant discharges facilitates proliferation of the pathogenic free-living amoebae that cause primary amoebic meningoencephalitis, water samples (250 ml) were taken from discharges within 3,000 feet (ca. 914.4 m) of power plants and were processed for amoeba culture. Pathogenic Naegleria fowleri grew out of water samples from two of five lakes and rivers in Florida and from one of eight man-made lakes in Texas. Pathogenic N. fowleri did not grow from water samples taken from cooling towers and control lakes, the latter of which had no associated power plants. The identification of N. fowleri was confirmed by pathogenicity in mice and by indirect immunofluorescence analyses, by using a specific antiserum.