WorldWideScience

Sample records for water heat pump

  1. Unitary water-to-air heat pumps

    Energy Technology Data Exchange (ETDEWEB)

    Christian, J.E.

    1977-10-01

    Performance and cost functions for nine unitary water-to-air heat pumps ranging in nominal size from /sup 1///sub 2/ to 26 tons are presented in mathematical form for easy use in heat pump computer simulations. COPs at nominal water source temperature of 60/sup 0/F range from 2.5 to 3.4 during the heating cycle; during the cooling cycle EERs range from 8.33 to 9.09 with 85/sup 0/F entering water source temperatures. The COP and EER values do not include water source pumping power or any energy requirements associated with a central heat source and heat rejection equipment.

  2. Field Monitoring Protocol: Heat Pump Water Heaters

    Energy Technology Data Exchange (ETDEWEB)

    Sparn, B.; Earle, L.; Christensen, D.; Maguire, J.; Wilson, E.; Hancock, E.

    2013-02-01

    This document provides a standard field monitoring protocol for evaluating the installed performance of Heat Pump Water Heaters in residential buildings. The report is organized to be consistent with the chronology of field test planning and execution. Research questions are identified first, followed by a discussion of analysis methods, and then the details of measuring the required information are laid out. A field validation of the protocol at a house near the NREL campus is included for reference.

  3. Field Monitoring Protocol. Heat Pump Water Heaters

    Energy Technology Data Exchange (ETDEWEB)

    Sparn, B. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Earle, L. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Christensen, D. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Maguire, J. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Wilson, E. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Hancock, C. E. [Mountain Energy Partnership, Longmont, CO (United States)

    2013-02-01

    This document provides a standard field monitoring protocol for evaluating the installed performance of Heat Pump Water Heaters in residential buildings. The report is organized to be consistent with the chronology of field test planning and execution. Research questions are identified first, followed by a discussion of analysis methods, and then the details of measuring the required information are laid out. A field validation of the protocol at a house near the NREL campus is included for reference.

  4. Biocorrosion of evaporators of water/water heat pumps

    Energy Technology Data Exchange (ETDEWEB)

    Denier, P.; Sutter, E.M.M.; Cornet, A. (Ecole Nationale Superieure des Arts et Industries, 67 - Strasbourg (FR))

    1990-12-01

    During the last twenty years, many heat pumps were installed in Alsace (France) using groundwater. It appeared that water contained bacteria able to induce metallic corrosion. Thus, it was necessary to have a better knowledge of the situation. A statistical study on water analysis was realised. There is no noticeable relation between bacterial contamination and water chemistry or geographical location. Most of corrosion origines were - a bad water network conception (erosion, cavitation, oxygen differential cells...) - a bad use of metal coupling (galvanic corrosion). The presence of bacteria generally increases the phenomena described above. Solutions proposed are: PVC casing, stainless steel water pumps, heat pump evaporators in noble alloys or metals, PVC or resines lagging. For the actual set of heat pumps, there are less solutions but in some cases an intermediary exchanger would be a good and easy solution.

  5. Multifamily Heat Pump Water Heater Evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Hoeschele, M. [Davis Energy Group, Davis, CA (United States). Alliance for Residential Building Innovation; Weitzel, E. [Davis Energy Group, Davis, CA (United States). Alliance for Residential Building Innovation

    2017-03-03

    Although heat pump water heaters (HPWHs) have gained significant attention in recent years as a high efficiency electric water heating solution for single family homes, central HPWHs for commercial or multi-family applications are not as well documented in terms of measured performance and cost effectiveness. To evaluate this technology, the Alliance for Residential Building Innovation team monitored the performance of a 10.5 ton central HPWH installed on a student apartment building at the West Village Zero Net Energy Community in Davis, California. Monitoring data collected over a 16 month period were then used to validate a TRNSYS simulation model. The TRNSYS model was then used to project performance in different climates using local electric rates. Results of the study indicate that after some initial commissioning issues, the HPWH operated reliably with an annual average efficiency of 2.12 (Coefficient of Performance). The observed efficiency was lower than the unit's rated efficiency, primarily due to the fact that the system rarely operated under steady-state conditions. Changes in the system configuration, storage tank sizing, and control settings would likely improve the observed field efficiency. Modeling results suggest significant energy savings relative to electric storage water heating systems (typical annual efficiencies around 0.90) providing for typical simple paybacks of six to ten years without any incentives. The economics versus gas water heating are currently much more challenging given the current low natural gas prices in much of the country. Increased market size for this technology would benefit cost effectiveness and spur greater technology innovation.

  6. Multifamily Heat Pump Water Heater Evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Hoeschele, M. [Alliance for Residential Building Innovation (ARBI), Davis, CA (United States); Weitzel, E. [Alliance for Residential Building Innovation (ARBI), Davis, CA (United States)

    2013-11-22

    Although heat pump water heaters (HPWHs) have gained significant attention in recent years as a high efficiency electric water heating solution for single family homes, central HPWHs for commercial or multi-family applications are not as well documented in terms of measured performance and cost effectiveness. To evaluate this technology, the Alliance for Residential Building Innovation team monitored the performance of a 10.5 ton central HPWH installed on a student apartment building at the West Village Zero Net Energy Community in Davis, California. Monitoring data collected over a 16 month period were then used to validate a TRNSYS simulation model. The TRNSYS model was then used to project performance in different climates using local electric rates. Results of the study indicate that after some initial commissioning issues, the HPWH operated reliably with an annual average efficiency of 2.12 (Coefficient of Performance). The observed efficiency was lower than the unit's rated efficiency, primarily due to the fact that the system rarely operated under steady-state conditions. Changes in the system configuration, storage tank sizing, and control settings would likely improve the observed field efficiency. Modeling results suggest significant energy savings relative to electric storage water heating systems (typical annual efficiencies around 0.90) providing for typical simple paybacks of six to ten years without any incentives. The economics versus gas water heating are currently much more challenging given the current low natural gas prices in much of the country. Increased market size for this technology would benefit cost effectiveness and spur greater technology innovation.

  7. Multifamily Heat Pump Water Heater Evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Hoeschele, M. [Alliance for Residential Building Innovation (ARBI), Davis, CA (United States); Weitzel, E. [Alliance for Residential Building Innovation (ARBI), Davis, CA (United States)

    2017-03-01

    Although heat pump water heaters (HPWHs) have gained significant attention in recent years as a high efficiency electric water heating solution for single family homes, central HPWHs for commercial or multi-family applications are not as well documented in terms of measured performance and cost effectiveness. To evaluate this technology, the Alliance for Residential Building Innovation team monitored the performance of a 10.5 ton central HPWH installed on a student apartment building at the West Village Zero Net Energy Community in Davis, California. Monitoring data collected over a 16 month period were then used to validate a TRNSYS simulation model. The TRNSYS model was then used to project performance in different climates using local electric rates. Results of the study indicate that after some initial commissioning issues, the HPWH operated reliably with an annual average efficiency of 2.12 (Coefficient of Performance). The observed efficiency was lower than the unit's rated efficiency, primarily due to the fact that the system rarely operated under steady-state conditions. Changes in the system configuration, storage tank sizing, and control settings would likely improve the observed field efficiency. Modeling results suggest significant energy savings relative to electric storage water heating systems (typical annual efficiencies around 0.90) providing for typical simple paybacks of six to ten years without any incentives. The economics versus gas water heating are currently much more challenging given the current low natural gas prices in much of the country. Increased market size for this technology would benefit cost effectiveness and spur greater technology innovation.

  8. Performance analysis of air——water dual source heat pump water heater with heat recovery

    Institute of Scientific and Technical Information of China (English)

    CHEN ZeShao; TAO WenQuan; ZHU YanWen; HU Peng

    2012-01-01

    A new air-water dual source heat pump water heater with heat recovery is proposed.The heat pump system can heat water by using a single air source,a single water source,or air-water dual sources.The water is first pre-heated by waste hot water,then heated by the heat pump.Waste heat is recovered by first preheating the cold water and as water source of the heat pump.According to the correlated formulas of the coefficient of performance of air-source heat pump and water-source heat pump,and the gain coefficient of heat recovery-preheater,the formulas for the coefficient of performance of heat pump in six operating modes are obtained by using the dimensionless correspondence analysis method.The system characteristics of heat absorption and release associated with the heat recovery-preheater are analyzed at different working conditions.The developed approaches can provide reference for the optimization of the operating modes and parameters.The results of analysis and experiments show that the coefficient of performance of the device can reach 4-5.5 in winter,twice as much as air source heat pump water heater.The utilization of waste heat in the proposed system is higher than that in the system which only uses waste water to preheating or as heat source.Thus,the effect of energy saving of the new system is obvious.On the other hand,the dimensionless correspondence analysis method is introduced to performance analysis of the heat pump,which also has theoretical significance and practical value.

  9. Residential CO2 Heat Pump System for Combined Space Heating and Hot Water Heating

    OpenAIRE

    Stene, Jørn

    2004-01-01

    Carbon dioxide (CO2, R-744) has been identified as a promising alternative to conventional working fluids in a number of applications due to its favourable environmental and thermophysical properties. Previous work on residential CO2 heat pumps has been dealing with systems for either space heating or hot water heating, and it was therefore considered interesting to carry out a theoretical and experimental study of residential CO2 heat pump systems for combined space heating and hot water hea...

  10. Field Performance of Heat Pump Water Heaters in the Northeast

    Energy Technology Data Exchange (ETDEWEB)

    Shapiro, Carl [Consortium for Advanced Residential Buildings, Norwalk, CT (United States); Puttagunta, Srikanth [Consortium for Advanced Residential Buildings, Norwalk, CT (United States)

    2016-02-01

    Heat pump water heaters (HPWHs) are finally entering the mainstream residential water heater market. Potential catalysts are increased consumer demand for higher energy efficiency electric water heating and a new Federal water heating standard that effectively mandates use of HPWHs for electric storage water heaters with nominal capacities greater than 55 gallons. When compared to electric resistance water heating, the energy and cost savings potential of HPWHs is tremendous. Converting all electric resistance water heaters to HPWHs could save American consumers 7.8 billion dollars annually ($182 per household) in water heating operating costs and cut annual residential source energy consumption for water heating by 0.70 quads.

  11. Refrigerant charge management in a heat pump water heater

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Jie; Hampton, Justin W.

    2016-07-05

    Heat pumps that heat or cool a space and that also heat water, refrigerant management systems for such heat pumps, and methods of managing refrigerant charge. Various embodiments remove idle refrigerant from a heat exchanger that is not needed for transferring heat by opening a refrigerant recovery valve and delivering the idle refrigerant from the heat exchanger to an inlet port on the compressor. The heat exchanger can be isolated by closing an electronic expansion valve, actuating a refrigerant management valve, or both. Refrigerant charge can be controlled by controlling how much refrigerant is drawn from the heat exchanger, by letting some refrigerant back into the heat exchanger, or both. Heat pumps can be operated in different modes of operation, and various components can be interconnected with refrigerant conduit. Some embodiments deliver refrigerant gas to the heat exchanger and drive liquid refrigerant out prior to isolating the heat exchanger.

  12. Energy Savings Potential for Pumping Water in District Heating Stations

    Directory of Open Access Journals (Sweden)

    Ioan Sarbu

    2015-05-01

    Full Text Available In district heating stations, the heat carrier is circulated between the energy source and consumers by a pumping system. Fluid handling systems, such as pumping systems, are responsible for a significant portion of the total electrical energy use. Significant opportunities exist to reduce pumping energy through smart design, retrofitting, and operating practices. Most existing systems requiring flow control make use of bypass lines, throttling valves or pump speed adjustments. The most efficient of these options is pump speed control. One of the issues in using variable-speed pumping systems, however, is the total efficiency of the electric motor/pump arrangement under a given operating condition. This paper provides a comprehensive discussion about pump control in heating stations and analyzes the energy efficiency of flow control methods. Specific attention is also given to the selection of motor types, sizing and pump duty cycle. A comparative energy analysis is performed on the hot water discharge adjustment using throttling control valves and variable-speed drives in a district heating station constructed in Romania. To correlate the pumped flow rate with the heat demand and to ensure the necessary pressure using minimum energy, an automatic system has been designed. The performances of these control methods are evaluated in two practical applications. The results show that approximately 20%–50% of total pumping energy could be saved by using the optimal control method with variable-speed pumps. Additionally, some modernization solutions to reduce the environmental impact of heating stations are described.

  13. Computational Simulation of a Water-Cooled Heat Pump

    Science.gov (United States)

    Bozarth, Duane

    2008-01-01

    A Fortran-language computer program for simulating the operation of a water-cooled vapor-compression heat pump in any orientation with respect to gravity has been developed by modifying a prior general-purpose heat-pump design code used at Oak Ridge National Laboratory (ORNL).

  14. Corrosion protection of steel in ammonia/water heat pumps

    Science.gov (United States)

    Mansfeld, Florian B.; Sun, Zhaoli

    2003-10-14

    Corrosion of steel surfaces in a heat pump is inhibited by adding a rare earth metal salt to the heat pump's ammonia/water working fluid. In preferred embodiments, the rare earth metal salt includes cerium, and the steel surfaces are cerated to enhance the corrosion-inhibiting effects.

  15. Residential CO{sub 2} heat pump system for combined space heating and hot water heating

    Energy Technology Data Exchange (ETDEWEB)

    Stene, Joern

    2004-02-01

    Carbon dioxide (CO{sub 2}, R-744) has been identified as a promising alternative to conventional working fluids in a number of applications due to its favourable environmental and thermophysical properties. Previous work on residential CO{sub 2} heat pumps has been dealing with systems for either space heating or hot water heating, and it was therefore considered interesting to carry out a theoretical and experimental study of residential CO{sub 2} heat pump systems for combined space heating and hot water heating - o-called integrated CO{sub 2} heat pump systems. The scope of this thesis is limited to brine-to-water and water-to-water heat pumps connected to low-temperature hydronic space heating systems. The main conclusions are: (1) Under certain conditions residential CO{sub 2} heat pump systems for combined space heating and hot water heating may achieve the same or higher seasonal performance factor (SPF) than the most energy efficient state-of-the-art brine-to-water heat pumps. (2) In contrary to conventional heat pump systems for combined space heating and DHW heating, the integrated CO{sub 2} heat pump system achieves the highest COP in the combined heating mode and the DHW heating mode, and the lowest COP in the space heating mode. Hence, the larger the annual DHW heating demand, the higher the SPF of the integrated CO{sub 2} heat pump system. (3) The lower the return temperature in the space heating system and the lower the DHW storage temperature, the higher the COP of the integrated CO{sub 2} heat pump. A low return temperature in the space heating system also results in a moderate DHW heating capacity ratio, which means that a relatively large part of the annual space heating demand can be covered by operation in the combined heating mode, where the COP is considerably higher than in the space heating mode. (4) During operation in the combined heating mode and the DHW heating mode, the COP of the integrated CO{sub 2} heat pump is heavily influenced by

  16. Air-to-water heat pumps for the home

    Energy Technology Data Exchange (ETDEWEB)

    Bodzin, S. [ed.

    1997-07-01

    Heat pump water heaters may be on the rise again. Retrofitters have shied away from this form of water heating due to concerns about cost, moise, efficiency, and maintaenance. Recent advances have overcome some of these problems and are helping the technology find a niche in both hot and cold climates. The topics covered in this article include the following: how heat pump water heaters work; air source from where to where, including air conditioning, heat recovery ventilation, hybrid systems; nuisances; maintenance; costs; to install or not to install; performance: a trick to quantify. 2 figs.

  17. Heat pumps

    CERN Document Server

    Macmichael, DBA

    1988-01-01

    A fully revised and extended account of the design, manufacture and use of heat pumps in both industrial and domestic applications. Topics covered include a detailed description of the various heat pump cycles, the components of a heat pump system - drive, compressor, heat exchangers etc., and the more practical considerations to be taken into account in their selection.

  18. Heat pumps

    CERN Document Server

    Brodowicz, Kazimierz; Wyszynski, M L; Wyszynski

    2013-01-01

    Heat pumps and related technology are in widespread use in industrial processes and installations. This book presents a unified, comprehensive and systematic treatment of the design and operation of both compression and sorption heat pumps. Heat pump thermodynamics, the choice of working fluid and the characteristics of low temperature heat sources and their application to heat pumps are covered in detail.Economic aspects are discussed and the extensive use of the exergy concept in evaluating performance of heat pumps is a unique feature of the book. The thermodynamic and chemical properties o

  19. Low Temperature District Heating Consumer Unit with Micro Heat Pump for Domestic Hot Water Preparation

    DEFF Research Database (Denmark)

    Zvingilaite, Erika; Ommen, Torben Schmidt; Elmegaard, Brian

    2012-01-01

    In this paper we present and analyse the feasibility of a district heating (DH) consumer unit with micro heat pump for domestic hot water (DHW) preparation in a low temperature (40 °C) DH network. We propose a micro booster heat pump of high efficiency (COP equal to 5,3) in a consumer DH unit...... in order to boost the temperature of the district heating water for heating the DHW. The paper presents the main designs of the suggested system and different alternative micro booster heat pump concepts. Energy efficiency and thermodynamic performance of these concepts are calculated and compared....... The results show that the proposed system has the highest efficiency. Furthermore, we compare thermodynamic and economic performance of the suggested heat pump-based concept with different solutions, using electric water heater. The micro booster heat pump system has the highest annualised investment (390 EUR...

  20. Application of Heat Pump in Cooling Water System of HIRFL

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    Accelerator generates a lot of heat when it is working.It must be cooled by the circulating cooling water.Generally the heat was released to atimosphere by the cooling water tower.Because the heat energy is very huge(about 2M watts for HIRFL),it is big waste and the machine can’t be cooled to appropriate temperature when ambient temperature is high in summer.In order to solve the problems,the heat pump has been used

  1. Technical and Economic Working Domains of Industrial Heat Pumps: Part 2 - Ammonia-Water Hybrid Absorption-Compression Heat Pumps

    DEFF Research Database (Denmark)

    Jensen, Jonas Kjær; Ommen, Torben Schmidt; Markussen, Wiebke Brix

    2014-01-01

    The ammonia-water hybrid absorption-compression heat pump (HACHP) is a relevant technology for industrial heat supply, especially for high sink temperatures and high temperature glides in the sink and source. This is due to the reduced vapour pressure and the non-isothermal phase change...... of the zeotropic mixture, ammonia-water. To evaluate to which extent these advantages can be translated into feasible heat pump solutions, the working domain of the HACHP is investigated based on technical and economic constraints. The HACHP working domain is compared to that of the best possible vapour...... compression heat pump with natural working fluids. This shows that the HACHP increases the temperature lifts and heat supply temperatures that are feasible to produce with a heat pump. The HACHP is shown to be capable of delivering heat supply temperatures as high as 140 XC and temperature lifts up to 60 K...

  2. Technical and economic working domains of industrial heat pumps: Part 2 - ammonia-water hybrid absorption-compression heat pumps

    DEFF Research Database (Denmark)

    Jensen, Jonas Kjær; Ommen, Torben Schmidt; Markussen, Wiebke Brix

    2015-01-01

    The ammonia-water hybrid absorption-compression heat pump (HACHP) has been proposed as a relevant technology for industrial heat supply, especially for high sink temperatures and high temperature glides in the sink and source. This is due to the reduced vapour pressure and the non-isothermal phase...... change of the zeotropic mixture, ammonia-water. To evaluate to which extent these advantages can be translated into feasible heat pump solutions, the working domain of the HACHP is investigated based on technical and economic constraints. The HACHP working domain is compared to that of the best available...... vapour compression heat pump with natural working fluids. This shows that the HACHP increases the temperature lifts and heat supply temperatures that are feasible to produce with a heat pump. The HACHP is shown to be capable of delivering heat supply temperatures as high as 150 °C and temperature lifts...

  3. Laboratory Performance Evaluation of Residential Integrated Heat Pump Water Heaters

    Energy Technology Data Exchange (ETDEWEB)

    Sparn, B.; Hudon, K.; Christensen, D.

    2014-06-01

    This paper explores the laboratory performance of five integrated Heat Pump Water Heaters (HPWHs) across a wide range of operating conditions representative of US climate regions. HPWHs are expected to provide significant energy savings in certain climate zones when compared to typical electric resistance water heaters. Results show that this technology is a viable option in most climates, but differences in control schemes and design features impact the performance of the units tested. Tests were conducted to map heat pump performance across the operating range and to determine the logic used to control the heat pump and the backup electric heaters. Other tests performed include two unique draw profile tests, reduced air flow performance tests and the standard DOE rating tests. The results from all these tests are presented here for all five units tested. The results of these tests will be used to improve the EnergyPlus heat pump water heater for use in BEopt(tm) whole-house building simulations.

  4. Laboratory Performance Evaluation of Residential Integrated Heat Pump Water Heaters

    Energy Technology Data Exchange (ETDEWEB)

    Sparn, B.; Hudon, K.; Christensen, D.

    2014-06-01

    This paper explores the laboratory performance of five integrated Heat Pump Water Heaters (HPWHs) across a wide range of operating conditions representative of U.S. climate regions. HPWHs are expected to provide significant energy savings in certain climate zones when compared to typical electric resistance water heaters. Results show that this technology is a viable option in most climates, but differences in control schemes and design features impact the performance of the units tested. Tests were conducted to map heat pump performance across the operating range and to determine the logic used to control the heat pump and the backup electric heaters. Other tests performed include two unique draw profile tests, reduced air flow performance tests and the standard DOE rating tests. The results from all these tests are presented here for all five units tested. The results of these tests will be used to improve the EnergyPlus heat pump water heater for use in BEopt™ whole-house building simulations.

  5. Performance analysis on solar-water compound source heat pump for radiant floor heating system

    Institute of Scientific and Technical Information of China (English)

    曲世林; 马飞; 仇安兵

    2009-01-01

    A solar-water compound source heat pump for radiant floor heating (SWHP-RFH) experimental system was introduced and analyzed. The SWHP-RFH system mainly consists of 11.44 m2 vacuum tube solar collector,1 000 L water tank assisted 3 kW electrical heater,a water source heat pump,the radiant floor heating system with cross-linked polyethylene (PE-X) of diameter 20 mm,temperature controller and solar testing system. The SWHP-RFH system was tested from December to February during the heating season in Beijing,China under different operation situations. The test parameters include the outdoor air temperature,solar radiation intensity,indoor air temperature,radiation floor average surface temperature,average surface temperature of the building envelope,the inlet and outlet temperatures of solar collector,the temperature of water tank,the heat medium temperatures of heat pump condenser side and evaporator side,and the power consumption includes the water source heat pump system,the solar source heat pump system,the auxiliary heater and the radiant floor heating systems etc. The experimental results were used to calculate the collector efficiency,heat pump dynamic coefficient of performance (COP),total energy consumption and seasonal heating performance during the heating season. The results indicate that the performance of the compound source heat pump system is better than that of the air source heat pump system. Furthermore,some methods are suggested to improve the thermal performance of each component and the whole SWHP-RFH system.

  6. High Efficiency R-744 Commercial Heat Pump Water Heaters

    Energy Technology Data Exchange (ETDEWEB)

    Elbel, Dr. Stefan W.; Petersen, Michael

    2013-04-25

    The project investigated the development and improvement process of a R744 (CO2) commercial heat pump water heater (HPWH) package of approximately 35 kW. The improvement process covered all main components of the system. More specific the heat exchangers (Internal heat exchanger, Evaporator, Gas cooler) as well as the expansion device and the compressor were investigated. In addition, a comparison to a commercially available baseline R134a unit of the same capacity and footprint was made in order to compare performance as well as package size reduction potential.

  7. Experimental investigation on water quality standard of Yangtze River water source heat pump.

    Science.gov (United States)

    Qin, Zenghu; Tong, Mingwei; Kun, Lin

    2012-01-01

    Due to the surface water in the upper reaches of Yangtze River in China containing large amounts of silt and algae, high content of microorganisms and suspended solids, the water in Yangtze River cannot be used for cooling a heat pump directly. In this paper, the possibility of using Yangtze River, which goes through Chongqing, a city in southwest China, as a heat source-sink was investigated. Water temperature and quality of the Yangtze River in the Chongqing area were analyzed and the performance of water source heat pump units in different sediment concentrations, turbidity and algae material conditions were tested experimentally, and the water quality standards, in particular surface water conditions, in the Yangtze River region that adapt to energy-efficient heat pumps were also proposed. The experimental results show that the coefficient of performance heat pump falls by 3.73% to the greatest extent, and the fouling resistance of cooling water in the heat exchanger increases up to 25.6% in different water conditions. When the sediment concentration and the turbidity in the river water are no more than 100 g/m3 and 50 NTU respectively, the performance of the heat pump is better, which can be used as a suitable river water quality standard for river water source heat pumps.

  8. Development of a nonazeotropic heat pump for crew hygiene water heating

    Science.gov (United States)

    Walker, David H.; Deming, Glenn I.

    1991-01-01

    A Phase 2 SBIR Program funded by the NASA Marshall Space Flight Center to develop a Nonazeotropic Heat Pump is described. The heat pump system which was designed, fabricated, and tested in the Foster-Miller laboratory, is capable of providing crew hygiene water heating for future manned missions. The heat pump utilizes a nonazeotropic refrigerant mixture which, in this application, provides a significant Coefficient of Performance improvement over a single-constituent working fluid. In order to take full advantage of the refrigerant mixture, compact tube-in-tube heat exchangers were designed. A high efficiency scroll compressor with a proprietary lubrication system was developed to meet the requirements of operation in zero-gravity. The prototype heat pump system consumes less than 200W of power compared to the alternative of electric cartridge heaters which would require 2 to 5 kW.

  9. Demand Response Performance of GE Hybrid Heat Pump Water Heater

    Energy Technology Data Exchange (ETDEWEB)

    Widder, Sarah H.; Parker, Graham B.; Petersen, Joseph M.; Baechler, Michael C.

    2013-07-01

    This report describes a project to evaluate and document the DR performance of HPWH as compared to ERWH for two primary types of DR events: peak curtailments and balancing reserves. The experiments were conducted with GE second-generation “Brillion”-enabled GeoSpring hybrid water heaters in the PNNL Lab Homes, with one GE GeoSpring water heater operating in “Standard” electric resistance mode to represent the baseline and one GE GeoSpring water heater operating in “Heat Pump” mode to provide the comparison to heat pump-only demand response. It is expected that “Hybrid” DR performance, which would engage both the heat pump and electric elements, could be interpolated from these two experimental extremes. Signals were sent simultaneously to the two water heaters in the side-by-side PNNL Lab Homes under highly controlled, simulated occupancy conditions. This report presents the results of the evaluation, which documents the demand-response capability of the GE GeoSpring HPWH for peak load reduction and regulation services. The sections describe the experimental protocol and test apparatus used to collect data, present the baselining procedure, discuss the results of the simulated DR events for the HPWH and ERWH, and synthesize key conclusions based on the collected data.

  10. Field Performance of Heat Pump Water Heaters in the Northeast

    Energy Technology Data Exchange (ETDEWEB)

    Shapiro, Carl [Consortium for Advanced Residential Buildings, Norfolk, CT (United States); Puttagunta, Srikanth [Consortium for Advanced Residential Buildings, Norfolk, CT (United States)

    2016-02-05

    Heat pump water heaters (HPWHs) are finally entering the mainstream residential water heater market. Potential catalysts are increased consumer demand for higher energy efficiency electric water heating and a new Federal water heating standard that effectively mandates use of HPWHs for electric storage water heaters with nominal capacities greater than 55 gallons. When compared to electric resistance water heating, the energy and cost savings potential of HPWHs is tremendous. Converting all electric resistance water heaters to HPWHs could save American consumers 7.8 billion dollars annually ($182 per household) in water heating operating costs and cut annual residential source energy consumption for water heating by 0.70 quads. Steven Winter Associates, Inc. embarked on one of the first in situ studies of these newly released HPWH products through a partnership with two sponsoring electric utility companies, National Grid and NSTAR, and one sponsoring energy efficiency service program administrator, Cape Light Compact. Recent laboratory studies have measured performance of HPWHs under various operating conditions, but publically available field studies have not been as available. This evaluation attempts to provide publicly available field data on new HPWHs by monitoring the performance of three recently released products (General Electric GeoSpring(TM), A.O. Smith Voltex(R), and Stiebel Eltron Accelera(R) 300). Fourteen HPWHs were installed in Massachusetts and Rhode Island and monitored for over a year. Of the 14 units, ten were General Electric models (50 gallon units), two were Stiebel Eltron models (80 gallon units), and two were A.O. Smith models (one 60-gallon and one 80-gallon unit).

  11. Field Performance of Heat Pump Water Heaters in the Northeast

    Energy Technology Data Exchange (ETDEWEB)

    Shapiro, C.; Puttagunta, S.

    2013-08-01

    Heat pump water heaters (HPWHs) are finally entering the mainstream residential water heater market. Potential catalysts are increased consumer demand for higher energy efficiency electric water heating and a new Federal water heating standard that effectively mandates use of HPWHs for electric storage water heaters with nominal capacities greater than 55 gallons. When compared to electric resistance water heating, the energy and cost savings potential of HPWHs is tremendous. Converting all electric resistance water heaters to HPWHs could save American consumers 7.8 billion dollars annually ($182 per household) in water heating operating costs and cut annual residential source energy consumption for water heating by 0.70 quads. Steven Winter Associates, Inc. embarked on one of the first in situ studies of these newly released HPWH products through a partnership with two sponsoring electric utility companies, National Grid and NSTAR, and one sponsoring energy efficiency service program administrator, Cape Light Compact. Recent laboratory studies have measured performance of HPWHs under various operating conditions, but publicly available field studies have not been as available. This evaluation attempts to provide publicly available field data on new HPWHs by monitoring the performance of three recently released products (General Electric GeoSpring(tm), A.O. Smith Voltex(r), and Stiebel Eltron Accelera(r)300). Fourteen HPWHs were installed in Massachusetts and Rhode Island and monitored for over a year. Of the 14 units, ten were General Electric models (50 gallon units), two were Stiebel Eltron models (80 gallon units), and two were A.O. Smith models (one 60-gallon and one 80-gallon unit).

  12. Hot water preparation using only a heat-pump; Warmwasserbereitung immer mit Waermepumpe

    Energy Technology Data Exchange (ETDEWEB)

    Mayer, H.; Gabathuler, H. R. [Gabathuler AG, beratende Ingenieure, Diessenhofen (Switzerland); Baumgartner, T. [Th. Baumgartner und Partner AG, Duebendorf (Switzerland)

    2007-07-01

    This article discusses the use of heat-pumps to heat up domestic hot water. The authors note that previously, heat-pumps were used to provide only space heating and domestic hot water was heated up using separate electrical heating elements. The results of a research and development project that defined standard configurations for small heat-pump installations that also provide hot water are discussed. An existing installation with two heat-pumps with ground-loop heat probes and a hot water store was used for tests. Measurements made and the results obtained are presented and discussed. Six configuration variants are described and their operation examined in detail. It is concluded that heat pumps may always be used for hot water preparation despite hygiene regulations demanding hot water temperatures up to 60 {sup o}C to prevent legionella growth.

  13. Efficient air-water heat pumps for high temperature lift residential heating, including oil migration aspects

    OpenAIRE

    Zehnder, Michele; Favrat, Daniel

    2005-01-01

    This thesis presents a system approach with the aim to develop improved concepts for small capacity, high temperature lift air-water heat pumps. These are intended to replace fuel fired heating systems in the residential sector, which leads to a major reduction of the local greenhouse gas emissions. Unfavorable temperature conditions set by the existing heat distribution systems and by the use of atmospheric air, as the only accessible heat source, have to be overcome. The proposed concepts a...

  14. Theoretical heating coefficient of a heat pump water heater with heat recovery applied in household bathing room

    Institute of Scientific and Technical Information of China (English)

    KOUGuangxiao; WANGHanqing; GUWeili; KOUJianguo

    2003-01-01

    Presents the components and flow diagram of a heat pump water heater with heat reclaim applied In household bathing room, analyzes its characteristics from thermodynamical principle, calculates its theoretical heating coefficient under different operating conditions. The result shows that the maximum value of its heating coefficient is 12.9 under a typical operating condition.

  15. Nonazeotropic Heat Pump

    Science.gov (United States)

    Ealker, David H.; Deming, Glenn

    1991-01-01

    Heat pump collects heat from water circulating in heat-rejection loop, raises temperature of collected heat, and transfers collected heat to water in separate pipe. Includes sealed motor/compressor with cooling coils, evaporator, and condenser, all mounted in outer housing. Gradients of temperature in evaporator and condenser increase heat-transfer efficiency of vapor-compression cycle. Intended to recover relatively-low-temperature waste heat and use it to make hot water.

  16. Nonazeotropic Heat Pump

    Science.gov (United States)

    Ealker, David H.; Deming, Glenn

    1991-01-01

    Heat pump collects heat from water circulating in heat-rejection loop, raises temperature of collected heat, and transfers collected heat to water in separate pipe. Includes sealed motor/compressor with cooling coils, evaporator, and condenser, all mounted in outer housing. Gradients of temperature in evaporator and condenser increase heat-transfer efficiency of vapor-compression cycle. Intended to recover relatively-low-temperature waste heat and use it to make hot water.

  17. Heat pump using dual heat sources of air and water. Performance in cooling mode; Mizu kuki ryonetsugen heat pump no kenkyu. Reibo unten ni okeru seino

    Energy Technology Data Exchange (ETDEWEB)

    Ito, S.; Miura, N. [Kanagawa Institute of Technology, Kanagawa (Japan); Uchikawa, Y. [Kubota Corp., Osaka (Japan)

    1997-11-25

    When a heat pump is used for cooling purpose, it is possible to utilize different kinds of waste water as high-heat sources. However, these heat sources would have their temperatures vary with seasons and time in a day. Therefore, a discussion was given on performance of a heat pump when water and air heat sources are used for condensers during cooling operation independently, in series and in parallel, respectively. The air condenser shows an equivalent COP as compared with the water condenser when air temperature is lower by about 8 degC than water temperature. At the same heat source temperature, the COP for the water condenser indicated a value higher by about 0.6 than the case of the air condenser. A method to use condensers in parallel experiences little contribution from the air heat source, and performance of the heat pump decreases below the case of using the water heat source independently when the air heat source temperature becomes higher than that of the water heat source. In the case of series use in which a water condenser is installed in front and an air condenser in rear, its effect is exhibited when temperature in the air heat source is lower than that in the water heat source. Better performance was shown than in operating the water heat source independently. 2 refs., 9 figs.

  18. Champagne Heat Pump

    Science.gov (United States)

    Jones, Jack A.

    2004-01-01

    The term champagne heat pump denotes a developmental heat pump that exploits a cycle of absorption and desorption of carbon dioxide in an alcohol or other organic liquid. Whereas most heat pumps in common use in the United States are energized by mechanical compression, the champagne heat pump is energized by heating. The concept of heat pumps based on other absorption cycles energized by heat has been understood for years, but some of these heat pumps are outlawed in many areas because of the potential hazards posed by leakage of working fluids. For example, in the case of the water/ammonia cycle, there are potential hazards of toxicity and flammability. The organic-liquid/carbon dioxide absorption/desorption cycle of the champagne heat pump is similar to the water/ammonia cycle, but carbon dioxide is nontoxic and environmentally benign, and one can choose an alcohol or other organic liquid that is also relatively nontoxic and environmentally benign. Two candidate nonalcohol organic liquids are isobutyl acetate and amyl acetate. Although alcohols and many other organic liquids are flammable, they present little or no flammability hazard in the champagne heat pump because only the nonflammable carbon dioxide component of the refrigerant mixture is circulated to the evaporator and condenser heat exchangers, which are the only components of the heat pump in direct contact with air in habitable spaces.

  19. Heat Pump Water Heater Durabliltiy Testing - Phase II

    Energy Technology Data Exchange (ETDEWEB)

    Baxter, VAND.

    2004-05-29

    Ten heat pump water heaters (HPWH) were placed in an environmentally controlled test facility and run through a durability test program of approximately 7300 duty cycles (actual cycles accumulated ranged from 6640 to 8324 for the ten units). Five of the units were upgraded integral types (HPWH mounted on storage tank, no pump) from the same manufacturer as those tested in our first durability program in 2001 (Baxter and Linkous, 2002). The other five were ''add-on'' type units (HPWH with circulation pump plumbed to a separate storage tank) from another manufacturer. This durability test was designed to represent approximately 7-10 years of normal operation to meet the hot water needs of a residence. The integral units operated without incident apart from two control board failures. Both of these were caused by inadvertent exposure to very hot and humid (>135 F dry bulb and >120 F dew point) conditions that occurred due to a test loop failure. It is not likely that any residential water heater would be installed where such conditions were expected so these failures are not considered a long-term reliability concern. Two of the integral HPWHs featured a condensate management system (CMS) option that effectively eliminated any need for an evaporator condensate drain, but imposed significant efficiency penalties when operating in high humidity ambient conditions. The add-on units experienced no operational failures (breakdowns with loss of hot water production) during the course of the testing. However, their control systems exhibited some performance degradation under the high temperature, high humidity test conditions--HPWHs would shut off with tank water temperatures 15-20 F lower than when operating under moderate ambient conditions. One unit developed a refrigerant leak during the test program and lost about 50% of its charge resulting in reduced efficiency. Efficiency measurements on all the integral units and four of the add-on units showed

  20. Heat Pump Water Heaters and American Homes: A Good Fit?

    Energy Technology Data Exchange (ETDEWEB)

    Franco, Victor; Lekov, Alex; Meyers, Steve; Letschert, Virginie

    2010-05-14

    Heat pump water heaters (HPWHs) are over twice as energy-efficient as conventional electric resistance water heaters, with the potential to save substantial amounts of electricity. Drawing on analysis conducted for the U.S. Department of Energy's recently-concluded rulemaking on amended standards for water heaters, this paper evaluates key issues that will determine how well, and to what extent, this technology will fit in American homes. The key issues include: 1) equipment cost of HPWHs; 2) cooling of the indoor environment by HPWHs; 3) size and air flow requirements of HPWHs; 4) performance of HPWH under different climate conditions and varying hot water use patterns; and 5) operating cost savings under different electricity prices and hot water use. The paper presents the results of a life-cycle cost analysis of the adoption of HPWHs in a representative sample of American homes, as well as national impact analysis for different market share scenarios. Assuming equipment costs that would result from high production volume, the results show that HPWHs can be cost effective in all regions for most single family homes, especially when the water heater is not installed in a conditioned space. HPWHs are not cost effective for most manufactured home and multi-family installations, due to lower average hot water use and the water heater in the majority of cases being installed in conditioned space, where cooling of the indoor environment and size and air flow requirements of HPWHs increase installation costs.

  1. Analysis of a Residential Heating System Utilizing a Solar Assisted Water-to-Air Heat Pump.

    Science.gov (United States)

    1979-07-01

    heat pump heating system were analyzed. A realistic residence and solar assisted water-to-air heat pump system were modeled for this northern climate using the transient simulation computer code TRNSYS developed by the University of Wisconsin. The system was studied over a one month winter period, December, using actual hourly weather data. The system was analyzed for both the cloudiest and clearest December weather recorded in the last 30 years. The collector area and storage tank capacity were varied and the effects on system performance were

  2. Development of an Air-Source Heat Pump Integrated with a Water Heating / Dehumidification Module

    Energy Technology Data Exchange (ETDEWEB)

    Rice, C Keith [ORNL; Uselton, Robert B. [Lennox Industries, Inc; Shen, Bo [ORNL; Baxter, Van D [ORNL; Shrestha, Som S [ORNL

    2014-01-01

    A residential-sized dual air-source integrated heat pump (AS-IHP) concept is under development in partnership between ORNL and a manufacturer. The concept design consists of a two-stage air-source heat pump (ASHP) coupled on the air distribution side with a separate novel water heating/dehumidification (WH/DH) module. The motivation for this unusual equipment combination is the forecast trend for home sensible loads to be reduced more than latent loads. Integration of water heating with a space dehumidification cycle addresses humidity control while performing double-duty. This approach can be applied to retrofit/upgrade applications as well as new construction. A WH/DH module capable of ~1.47 L/h water removal and ~2 kW water heating capacity was assembled by the manufacturer. A heat pump system model was used to guide the controls design; lab testing was conducted and used to calibrate the models. Performance maps were generated and used in a TRNSYS sub-hourly simulation to predict annual performance in a well-insulated house. Annual HVAC/WH energy savings of ~35% are predicted in cold and hot-humid U.S. climates compared to a minimum efficiency baseline.

  3. Regenerative adsorbent heat pump

    Science.gov (United States)

    Jones, Jack A. (Inventor)

    1991-01-01

    A regenerative adsorbent heat pump process and system is provided which can regenerate a high percentage of the sensible heat of the system and at least a portion of the heat of adsorption. A series of at least four compressors containing an adsorbent is provided. A large amount of heat is transferred from compressor to compressor so that heat is regenerated. The process and system are useful for air conditioning rooms, providing room heat in the winter or for hot water heating throughout the year, and, in general, for pumping heat from a lower temperature to a higher temperature.

  4. Vapor compression CuCl heat pump integrated with a thermochemical water splitting cycle

    Energy Technology Data Exchange (ETDEWEB)

    Zamfirescu, C., E-mail: Calin.Zamfirescu@uoit.ca [Faculty of Engineering and Applied Science, University of Ontario Institute of Technology (UOIT), 2000 Simcoe Street North, Oshawa, ON, Canada L1H 74K (Canada); Naterer, G.F., E-mail: Greg.Naterer@uoit.ca [Faculty of Engineering and Applied Science, University of Ontario Institute of Technology (UOIT), 2000 Simcoe Street North, Oshawa, ON, Canada L1H 74K (Canada); Dincer, I., E-mail: Ibrahim.Dincer@uoit.ca [Faculty of Engineering and Applied Science, University of Ontario Institute of Technology (UOIT), 2000 Simcoe Street North, Oshawa, ON, Canada L1H 74K (Canada)

    2011-01-10

    In this paper, the feasibility of using cuprous chloride (CuCl) as a working fluid in a new high temperature heat pump with vapor compression is analyzed. The heat pump is integrated with a copper-chlorine (Cu-Cl) thermochemical water splitting cycle for internal heat recovery, temperature upgrades and hydrogen production. The minimum temperature of heat supply necessary for driving the water splitting cycle can be lowered because the heat pump increases the working fluid temperature from 755 K up to {approx}950 K, at a high COP of {approx}6.5. Based on measured data available in past literature, the authors have determined the T-s diagram of CuCl, which is then used for the thermodynamic modeling of the cycle. In the heat pump cycle, molten CuCl is flashed in a vacuum where the vapor quality reaches {approx}2.5%, and then it is boiled to produce saturated vapor. The vapor is then compressed in stages (with inter-cooling and heat recovery), and condensed in a direct contact heat exchanger to transfer heat at a higher temperature. The heat pump is then integrated with a copper-chlorine water splitting plant. The heat pump evaporator is connected thermally with the hydrogen production reactor of the water splitting plant, which performs an exothermic reaction that generates heat at 760 K. Additional source heat is obtained from heat recovery from the hot reaction products of the oxy-decomposer. The heat pump transfers heat at {approx}950 K to the oxy-decomposer to drive its endothermic chemical reaction. It is shown that the heat required at the heat pump source can be obtained completely from internal heat recovery within the plant. First and second law analyses and a parametric study are performed for the proposed system to study the influence of the compressor's isentropic efficiency and temperature levels on the heat pump's COP. Two new indicators are presented: one represents the heat recovery ratio (the ratio between the thermal energy obtained by

  5. Domestic Hot Water Production with Ground Source Heat Pump in Apartment Buildings

    Directory of Open Access Journals (Sweden)

    Jukka Yrjölä

    2015-08-01

    Full Text Available Producing domestic hot water (DHW with a ground source heat pump (GSHP is challenging due to the high temperature (HT of DHW. There are many studies proving the better performance of cascade heat pumps compared to single-stage heat pumps when the difference between the condensing and the evaporation temperature is large. In this system approach study, different GSHP arrangements are described and computationally compared. A two-stage heat pump arrangement is introduced in which water tanks of the heating system are utilized for warming up the DHW in two stages. It is shown that the electricity consumption with this two-stage system is approximately 31% less than with the single-stage heat pump and 12% less than with the cascade system. Further, both low temperature (LT and HT heat pumps can run alone, which is not common in cascade or other two-stage heat pumps. This is advantageous because the high loads of the space heating and DHW production are not simultaneous. Proper insulation of the DHW and recirculation pipe network is essential, and drying towel rails or other heating coils should be avoided when aiming for a high efficiency. The refrigerants in the calculations are R407C for the LT heat pump and R134a for the HT heat pump. Investment costs are excluded from calculations.

  6. Demonstration of a heat pump water heater. Volume 3. Design report

    Energy Technology Data Exchange (ETDEWEB)

    Sloane, B.D.; Krise, R.C.; Kent, D.D.

    1979-12-01

    Work performed during the pilot run manufacturing and laboratory testing stages of a heat pump water heater for residential installations is described. A general description of the heat pump water heater is provided, as are detailed discussions of individual components. Also included is a description of the pilot run manufacturing facility and experience, laboratory operations, and laboratory test data.

  7. 16 CFR Appendix D5 to Part 305 - Water Heaters-Heat Pump

    Science.gov (United States)

    2010-01-01

    ... 16 Commercial Practices 1 2010-01-01 2010-01-01 false Water Heaters-Heat Pump D5 Appendix D5 to Part 305 Commercial Practices FEDERAL TRADE COMMISSION REGULATIONS UNDER SPECIFIC ACTS OF CONGRESS RULE... Appendix D5 to Part 305—Water Heaters—Heat Pump Range Information CAPACITY FIRST HOUR RATING Range of...

  8. Comfortable, high-efficiency heat pump with desiccant-coated, water-sorbing heat exchangers.

    Science.gov (United States)

    Tu, Y D; Wang, R Z; Ge, T S; Zheng, X

    2017-01-12

    Comfortable, efficient, and affordable heating, ventilation, and air conditioning systems in buildings are highly desirable due to the demands of energy efficiency and environmental friendliness. Traditional vapor-compression air conditioners exhibit a lower coefficient of performance (COP) (typically 2.8-3.8) owing to the cooling-based dehumidification methods that handle both sensible and latent loads together. Temperature- and humidity-independent control or desiccant systems have been proposed to overcome these challenges; however, the COP of current desiccant systems is quite small and additional heat sources are usually needed. Here, we report on a desiccant-enhanced, direct expansion heat pump based on a water-sorbing heat exchanger with a desiccant coating that exhibits an ultrahigh COP value of more than 7 without sacrificing any comfort or compactness. The pump's efficiency is doubled compared to that of pumps currently used in conventional room air conditioners, which is a revolutionary HVAC breakthrough. Our proposed water-sorbing heat exchanger can independently handle sensible and latent loads at the same time. The desiccants adsorb moisture almost isothermally and can be regenerated by condensation heat. This new approach opens up the possibility of achieving ultrahigh efficiency for a broad range of temperature- and humidity-control applications.

  9. Investigation of the Performance of a Heat Pump Using Waste Water as a Heat Source

    Directory of Open Access Journals (Sweden)

    Ali Kahraman

    2009-08-01

    Full Text Available In this research, a water-water heat pump system using waste water as a heat source, a type that is not often used in Turkey and the World, was experimentally modeled. The experiments were performed under the conditions of simulated waste water temperature values of 20 °C, 30 °C and 40 °C. Inlet and outlet water temperatures of the evaporator and condenser, water flow rates in the evaporator and condenser circuits, pressures at the compressor inlet and outlet and power consumption of the system were measured. The heating coefficients of performance were calculated based on the measurements. It was found that the maximum temperature in the energy storage tank was about 50.6 °C. For the heat source temperatures of 20 °C, 30 °C and 40 °C, the heating coefficients of the performance of the system became 3.36, 3.43 and 3.69, respectively, 6 min. after the start time of the experiments and then they were decreased to 1.87, 1.83 and 1.77 with increasing water temperature in the condenser tank. The mean uncertainty value of the measurement parameters was found to be about ±2.47%. Finally, for the purpose of meeting hot water need as well as floor heating system requirements, it is seen that energy quality level of a waste low grade temperature heat source can be increased by using a heat pump system.

  10. Heat pump applications and water heating by means of solar collectors. Waermepumpenanwendungen und Wasserwaermung mit Sonnenkollektoren

    Energy Technology Data Exchange (ETDEWEB)

    Szokody, G.

    1990-01-15

    About 25 to 30% of all newly constructed single-family houses in Switzerland are equipped with heat pump systems. This increasing attractivity is partly due to new techniques, e.g. microprocessor control, as well as to higher component efficiencies, a more efficient heat exchange technology, and to the compactness of systems. Active solar energy conversion, i.e. by means of solar collectors, is another technique which is predominantly applied for water heating in single-family buildings. Public investments in this field are scarce. (BWI).

  11. WEXA: exergy analysis for increasing the efficiency of air/water heat pumps - Final report

    Energy Technology Data Exchange (ETDEWEB)

    Gasser, L.; Wellig, B.; Hilfiker, K.

    2008-04-15

    This comprehensive final report for the Swiss Federal Office of Energy (SFOE) presents the results of a study at the made by the Engineering and Architecture department at the Lucerne University of Applied Sciences and Arts. The subject of the WEXA study (Waermepumpen-Exergie-Analyse - heat pump exergy analysis) is the analysis of the operation of air/water heat-pumps using exergy analysis methods. The basic thermodynamics of heating systems using heat-pumps is discussed. The exergy analyses and exergy balances for the various components and processes of an air/water heat-pump are presented and discussed. Comparisons are presented for heat-pumps with on/off and continuous control systems for their compressors and fans. The paper is concluded with a collection of appendices on the subject.

  12. On the development of high temperature ammonia-water hybrid absorption-compression heat pumps

    DEFF Research Database (Denmark)

    Jensen, Jonas Kjær; Markussen, Wiebke Brix; Reinholdt, Lars

    2015-01-01

    Ammonia-water hybrid absorption-compression heat pumps (HACHP) are a promising technology for development of ecient high temperature industrial heat pumps. Using 28 bar components HACHPs up to 100 °C are commercially available. Components developed for 50 bar and 140 bar show that these pressure...

  13. Conventional and advanced exergoenvironmental analysis of an ammonia-water hybridabsorption-compression heat pump

    DEFF Research Database (Denmark)

    Jensen, Jonas Kjær; Markussen, Wiebke Brix; Reinholdt, Lars

    2015-01-01

    The ammonia-water hybrid absorption-compression heat pump (HACHP) is a technology suitable for industrial scale heat pumps in the process industry. A helpful tool in the design of cost effective and low environmental impact energy conversion systems, such as the HACHP, is the application...

  14. Experimental Study of Thermoelectric Heat Pump Water Heater with Exhaust Heat Recovery from Kitchens

    Institute of Scientific and Technical Information of China (English)

    LIU Zhong-bing; ZHANG Ling; YANG Zhang; XU Ming; HAN Tian-he

    2009-01-01

    A new kind of thermoelectric heat pump water heater for kitchens exhaust heat recovery was pre-sented,and its performances were investigated under different operating voltages.The experiment results show that the coefficient of performance decreases and the temperature difference between the hot and cold sides be-comes larger with the increase of the operating voltage,but the heating time becomes short.The higher the temperature of water,the greater the temperature difference between the hot and cold sides,leading to a smaller eoeffieient of performance.Under an exhaust temperature of 36℃,the coefficient of performance decreases from 1.66 tO 1.22 when the temperature of water increases from 28℃to 46℃with operating voltage 16 V.Performance tests illustrate that,compared with the conventional electrical water heaters,the new kind of ther-moelectric heat pump water heater is more coefficient.

  15. Comfortable, high-efficiency heat pump with desiccant-coated, water-sorbing heat exchangers

    Science.gov (United States)

    Tu, Y. D.; Wang, R. Z.; Ge, T. S.; Zheng, X.

    2017-01-01

    Comfortable, efficient, and affordable heating, ventilation, and air conditioning systems in buildings are highly desirable due to the demands of energy efficiency and environmental friendliness. Traditional vapor-compression air conditioners exhibit a lower coefficient of performance (COP) (typically 2.8-3.8) owing to the cooling-based dehumidification methods that handle both sensible and latent loads together. Temperature- and humidity-independent control or desiccant systems have been proposed to overcome these challenges; however, the COP of current desiccant systems is quite small and additional heat sources are usually needed. Here, we report on a desiccant-enhanced, direct expansion heat pump based on a water-sorbing heat exchanger with a desiccant coating that exhibits an ultrahigh COP value of more than 7 without sacrificing any comfort or compactness. The pump’s efficiency is doubled compared to that of pumps currently used in conventional room air conditioners, which is a revolutionary HVAC breakthrough. Our proposed water-sorbing heat exchanger can independently handle sensible and latent loads at the same time. The desiccants adsorb moisture almost isothermally and can be regenerated by condensation heat. This new approach opens up the possibility of achieving ultrahigh efficiency for a broad range of temperature- and humidity-control applications.

  16. Comfortable, high-efficiency heat pump with desiccant-coated, water-sorbing heat exchangers

    Science.gov (United States)

    Tu, Y. D.; Wang, R. Z.; Ge, T. S.; Zheng, X.

    2017-01-01

    Comfortable, efficient, and affordable heating, ventilation, and air conditioning systems in buildings are highly desirable due to the demands of energy efficiency and environmental friendliness. Traditional vapor-compression air conditioners exhibit a lower coefficient of performance (COP) (typically 2.8–3.8) owing to the cooling-based dehumidification methods that handle both sensible and latent loads together. Temperature- and humidity-independent control or desiccant systems have been proposed to overcome these challenges; however, the COP of current desiccant systems is quite small and additional heat sources are usually needed. Here, we report on a desiccant-enhanced, direct expansion heat pump based on a water-sorbing heat exchanger with a desiccant coating that exhibits an ultrahigh COP value of more than 7 without sacrificing any comfort or compactness. The pump’s efficiency is doubled compared to that of pumps currently used in conventional room air conditioners, which is a revolutionary HVAC breakthrough. Our proposed water-sorbing heat exchanger can independently handle sensible and latent loads at the same time. The desiccants adsorb moisture almost isothermally and can be regenerated by condensation heat. This new approach opens up the possibility of achieving ultrahigh efficiency for a broad range of temperature- and humidity-control applications. PMID:28079171

  17. High efficient ammonia heat pump system for industrial process water using the ISEC concept. Part 1

    DEFF Research Database (Denmark)

    Rothuizen, Erasmus Damgaard; Madsen, C.; Elmegaard, Brian

    2014-01-01

    The purpose of the Isolated System Energy Charging (ISEC) is to provide a high-efficient ammonia heat pump system for hot water production. The ISEC concept uses two storage tanks for the water, one discharged and one charged. The charged tank is used for the industrial process while the discharged...... to investigate the performance of the ISEC system. The ISEC concept approaches the efficiency of a number of heat pumps in series and the COP of the system may reach 6.8, which is up to 25 % higher than a conventional heat pump heating water in one step....... tank, is charging. Charging is done by circulating the water in the tank through the condenser several times and thereby gradually heats the water. This result in a lower condensing temperature than if the water was heated in one step. A dynamic model of the system, implemented in Dymola, is used...

  18. Energetic Efficiency Evaluation by Using GroundWater Heat Pumps

    Directory of Open Access Journals (Sweden)

    Tokar Adriana

    2012-09-01

    Full Text Available Romania has significant energy potential from renewable sources, but the potential used is much lower due to technical and functional disadvantages, to economic efficiency, the cost elements and environmental limitations. However, efforts are being made to integrate renewable energy in the national energy system. To promote and encourage private investments for renewable energy utilization, programs have been created in order to access funds needed to implement these technologies. Assessment of such investments was carried out from technical and economical point of view, by analyzing a heat pump using as heat source the solar energy from the ground.

  19. Heat pump technology

    CERN Document Server

    Von Cube, Hans Ludwig; Goodall, E G A

    2013-01-01

    Heat Pump Technology discusses the history, underlying concepts, usage, and advancements in the use of heat pumps. The book covers topics such as the applications and types of heat pumps; thermodynamic principles involved in heat pumps such as internal energy, enthalpy, and exergy; and natural heat sources and energy storage. Also discussed are topics such as the importance of the heat pump in the energy industry; heat pump designs and systems; the development of heat pumps over time; and examples of practical everyday uses of heat pumps. The text is recommended for those who would like to kno

  20. Lunar Base Heat Pump

    Science.gov (United States)

    Walker, D.; Fischbach, D.; Tetreault, R.

    1996-01-01

    The objective of this project was to investigate the feasibility of constructing a heat pump suitable for use as a heat rejection device in applications such as a lunar base. In this situation, direct heat rejection through the use of radiators is not possible at a temperature suitable for lde support systems. Initial analysis of a heat pump of this type called for a temperature lift of approximately 378 deg. K, which is considerably higher than is commonly called for in HVAC and refrigeration applications where heat pumps are most often employed. Also because of the variation of the rejection temperature (from 100 to 381 deg. K), extreme flexibility in the configuration and operation of the heat pump is required. A three-stage compression cycle using a refrigerant such as CFC-11 or HCFC-123 was formulated with operation possible with one, two or three stages of compression. Also, to meet the redundancy requirements, compression was divided up over multiple compressors in each stage. A control scheme was devised that allowed these multiple compressors to be operated as required so that the heat pump could perform with variable heat loads and rejection conditions. A prototype heat pump was designed and constructed to investigate the key elements of the high-lift heat pump concept. Control software was written and implemented in the prototype to allow fully automatic operation. The heat pump was capable of operation over a wide range of rejection temperatures and cooling loads, while maintaining cooling water temperature well within the required specification of 40 deg. C +/- 1.7 deg. C. This performance was verified through testing.

  1. Water source heat pumps for greenhouse soil cooling. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Spieser, H.

    1987-06-01

    In an attempt to diversify and grow flowers which are in high demand, growers are looking to produce certain exotic flowers which require unique growing conditions. One example is the Alstroemerias also knwon as the Peruvian Lily. If the plants are grown continuously at about 12-15/sup 0/C soil temperature, the plant will continue to flower regardless of air temperature and photoriod. These latter two factors are considered secondary to the importance of cool soil temperatures. Alstroemeria production is still relatively new to the greenhouse industry. Some controversy still exists as to the direct benefits of planned soil cooling. This project was set up to evaluate a mechanical soil cooling system for continuous year round Alstroemeria production. A heat pump soil cooling system was installed in two greenhouses each with dimensions of 16 m by 61 m. Combined these greenhouses have a growing area of 1952 m/sup 2/. These greenhouses are older wooden greenhouses, covered by double poly, air-inflated glazing. This system worked very well, maintaining the soil temperature at the proper levels throughout the spring and summer months. During the rest of the year the soil cooling system is used less intensely. During winter months when soil cooling is not required, the heat pumps provide base load heating to the greenhouse through fan forced unit heaters.

  2. Municipal water-based heat pump heating and/or cooling systems: Findings and recommendations. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Bloomquist, R.G. [Washington, State Univ., Pullman, WA (United States); Wegman, S. [South Dakota Utilities Commission (United States)

    1998-04-01

    The purpose of the present work was to determine if existing heat pump systems based on municipal water systems meet existing water quality standards, to analyze water that has passed through a heat pump or heat exchanger to determine if corrosion products can be detected, to determine residual chlorine levels in municipal waters on the inlet as well as the outlet side of such installations, to analyses for bacterial contaminants and/or regrowth due to the presence of a heat pump or heat exchanger, to develop and suggest criteria for system design and construction, to provide recommendations and specifications for material and fluid selection, and to develop model rules and regulations for the installation, operation, and monitoring of new and existing systems. In addition, the Washington State University (WSU) has evaluated availability of computer models that would allow for water system mapping, water quality modeling and system operation.

  3. European Regional Climate Zone Modeling of a Commercial Absorption Heat Pump Hot Water Heater

    Energy Technology Data Exchange (ETDEWEB)

    Sharma, Vishaldeep [ORNL; Shen, Bo [ORNL; Keinath, Chris [Stone Mountain Technologies, Inc., Johnson City; Garrabrant, Michael A. [Stone Mountain Technologies, Inc., Johnson City; Geoghegan, Patrick J [ORNL

    2017-01-01

    High efficiency gas-burning hot water heating takes advantage of a condensing heat exchanger to deliver improved combustion efficiency over a standard non-condensing configuration. The water heating is always lower than the gas heating value. In contrast, Gas Absorption Heat Pump (GAHP) hot water heating combines the efficiency of gas burning with the performance increase from a heat pump to offer significant gas energy savings. An ammonia-water system also has the advantage of zero Ozone Depletion Potential and low Global Warming Potential. In comparison with air source electric heat pumps, the absorption system can maintain higher coefficients of performance in colder climates. In this work, a GAHP commercial water heating system was compared to a condensing gas storage system for a range of locations and climate zones across Europe. The thermodynamic performance map of a single effect ammonia-water absorption system was used in a building energy modeling software that could also incorporate the changing ambient air temperature and water mains temperature for a specific location, as well as a full-service restaurant water draw pattern.

  4. Development and Validation of a Gas-Fired Residential Heat Pump Water Heater - Final Report

    Energy Technology Data Exchange (ETDEWEB)

    Michael Garrabrant; Roger Stout; Paul Glanville; Janice Fitzgerald; Chris Keinath

    2013-01-21

    For gas-fired residential water heating, the U.S. and Canada is predominantly supplied by minimum efficiency storage water heaters with Energy Factors (EF) in the range of 0.59 to 0.62. Higher efficiency and higher cost ($700 - $2,000) options serve about 15% of the market, but still have EFs below 1.0, ranging from 0.65 to 0.95. To develop a new class of water heating products that exceeds the traditional limit of thermal efficiency, the project team designed and demonstrated a packaged water heater driven by a gas-fired ammonia-water absorption heat pump. This gas-fired heat pump water heater can achieve EFs of 1.3 or higher, at a consumer cost of $2,000 or less. Led by Stone Mountain Technologies Inc. (SMTI), with support from A.O. Smith, the Gas Technology Institute (GTI), and Georgia Tech, the cross-functional team completed research and development tasks including cycle modeling, breadboard evaluation of two cycles and two heat exchanger classes, heat pump/storage tank integration, compact solution pump development, combustion system specification, and evaluation of packaged prototype GHPWHs. The heat pump system extracts low grade heat from the ambient air and produces high grade heat suitable for heating water in a storage tank for domestic use. Product features that include conventional installation practices, standard footprint and reasonable economic payback, position the technology to gain significant market penetration, resulting in a large reduction of energy use and greenhouse gas emissions from domestic hot water production.

  5. Design and Evaluation of a Photovoltaic/Thermal-Assisted Heat Pump Water Heating System

    Directory of Open Access Journals (Sweden)

    Huan-Liang Tsai

    2014-05-01

    Full Text Available This paper presents the design, modelling and performance evaluation of a photovoltaic/thermal-assisted heat pump water heating (PVTA-HPWH system. The cooling effect of a refrigerant simultaneously enhances the PVT efficiency and effectively improves the coefficient of performance (COP of the HPWH system. The proposed model was built in the MATLAB/Simulink environment by considering the reciprocal energy exchange between a PVT evaporator and a HPWH system. In addition, the power consumption needs of the HPWH are provided by the PV electricity using a model-based control methodology. System performance is evaluated through a real field test. The results have demonstrated the power autarchy of the proposed PVTA-HPWH system with better PVT efficiency and COP. In addition, the good agreement between the model simulation and the experimental measurements demonstrate the proposed model with sufficient confidence.

  6. Exergoeconomic optimization of an ammonia-water hybrid heat pump for heat supply in a spray drying facility

    DEFF Research Database (Denmark)

    Jensen, Jonas Kjær; Markussen, Wiebke Brix; Reinholdt, Lars

    2014-01-01

    Spray drying facilities are among the most energy intensive industrial processes. Using a heat pump to recover waste heat and replace gas combustion has the potential to attain both economic and emissions savings. In the case examined a drying gas of ambient air is heated to 200 XC. The inlet flow...... rate is 100,000 m3/h which yields a heat load of 6.1 MW. The exhaust air from the drying process is 80 XC. The implementation of an ammonia-water hybrid absorption-compression heat pump to partly cover the heat load is investigated. A thermodynamic analysis is applied to determine optimal circulation...... ratios for a number of ammonia mass fractions and heat pump loads. An exergoeconomic optimization is applied to minimize the lifetime cost of the system. Technological limitations are applied to constrain the solution to commercial components. The best possible implementation is identified in terms...

  7. Nano-porous-water Absorbents for Solid-absorbebt Heat Pump System

    Science.gov (United States)

    Mizota, Tadato; Nakayama, Noriaki

    Zeolite-water heat-pump system has been developed in these 25 years. Recently, an instant beer-cooling system has appeared by using the zeolite heat pump system as a commercial product. It takes so long time for the development since the first proposal. The most serious problem through the development has been of the ability of absorbents. Themaximum heat exchange capacity to date exceeds 1MJ•kg-1 for Mg89-A, which is comparable to the energy storage capacity of modern alkaline-ion batteries in weight-bases. But it needs high temperature heat sources more than 200°C for the activation. Absorbents useful at lower temperatures are thus desirable for effective use of various kinds of lower temperature heat sources Various nano-porous materials as well as zeolites now under investigation as candidates of heat-pump absorbents, such as silica-gels, allophane, imogolite, hydrotalcite, etc.

  8. Water temperature adjustment in spas by the aid of heat pumps

    Directory of Open Access Journals (Sweden)

    Riznić Dejan T.

    2012-01-01

    Full Text Available Mineral spas are considered an important national resource, used mainly for therapeutical and recreational purposes. However, raw mineral waters are often at temperatures different from the required ones and need to be cooled or heated to be adjusted to the level adequate for a specified purpose. For such an adjustment, energy is either released (when cooling down the mineral water or consumed (for heating up the mineral water. Heat pumps may be used to multiply the gain of energy when released, or reduce the energy needed for heating the water. The report deals with technical possibilities and economic benefits of the use of heat pumps in such case studies in two spas of Serbia, Mataruska spa near Kraljevo, and Bukovicka spa in Arandjelovac.

  9. Exergoeconomic optimization of an ammonia–water hybrid absorption–compression heat pump for heat supply in a spraydrying facility

    DEFF Research Database (Denmark)

    Jensen, Jonas Kjær; Markussen, Wiebke Brix; Reinholdt, Lars

    2015-01-01

    load of 6.1 MW. The exhaust air from the drying process is 80 C. The implementation of anammonia–water hybrid absorption–compression heat pump to partly cover the heat load is investigated. A thermodynamic analysis is applied to determine optimal circulation ratios for a number of ammonia mass...... fractions and heat pump loads. An exergo economic optimization is applied to minimize the lifetime cost of the system. Technological limitations are imposed to constrain the solution to commercial components. The best possible implementation is identified in terms of heat load, ammonia mass fraction...

  10. Performance of water source heat pump system using high-density polyethylene tube heat exchanger wound with square copper wire

    Directory of Open Access Journals (Sweden)

    Xin Wen Zhang

    2015-07-01

    Full Text Available Surface water source heat pump system is an energy-efficient heat pump system. Surface water heat exchanger is an important part of heat pump system that can affect the performance of the system. In order to enhance the performance of the system, the overall heat transfer coefficient (U value of the water exchanger using a 32A square copper coiled high-density polyethylene tube was researched. Comparative experiments were conducted between the performance of the coiled high-density polyethylene tube and the 32A smooth high-density polyethylene tube. At the same time, the coefficient of performance of the heat pump was investigated. According to the result, the U value of the coiled tube was 18% higher than that of the smooth tube in natural convection and 19% higher in forced convection. The coefficient of performance of the heat pump with the coiled tube is higher than that with the smooth tube. The economic evaluation of the coiled tube was also investigated.

  11. Evaluation of water source heat pumps for the Juneau, Alaska Area

    Energy Technology Data Exchange (ETDEWEB)

    Jacobsen, J.J.; King, J.C.; Eisenhauer, J.L.; Gibson, C.I.

    1980-07-01

    The purposes of this project were to evaluate the technical and economic feasibility of water source heat pumps (WSHP) for use in Juneau, Alaska and to identify potential demonstration projects to verify their feasibility. Information is included on the design, cost, and availability of heat pumps, possible use of seawater as a heat source, heating costs with WSHP and conventional space heating systems, and life cycle costs for WSHP-based heating systems. The results showed that WSHP's are technically viable in the Juneau area, proper installation and maintenance is imperative to prevent equipment failures, use of WSHP would save fuel oil but increase electric power consumption. Life cycle costs for WSHP's are about 8% above that for electric resistance heating systems, and a field demonstration program to verify these results should be conducted. (LCL)

  12. Advanced heat pump cycle

    Energy Technology Data Exchange (ETDEWEB)

    Groll, E.A.; Radermacher, R.

    1993-07-01

    The desorption and absorption process of a vapor compression heat pump with a solution circuit (VCHSC) proceeds at gliding temperature intervals, which can be adjusted over a wide range. In case that the gliding temperature intervals in the desorber and the absorber overlap, a modification of the VCHSC employing a desorber/absorber heat exchange (DAHX) can be introduced, which results in an extreme reduction of the pressure ratio. Although the DAHX-cycle has features of a two-stage cycle, it still requires only one solution pump, one separator and one compressor. Such a cycle for the working pair ammonia/water is built in the Energy Laboratory of the Center for Environmental Energy Engineering at the University of Maryland. The experimental results obtained with the research plant are discussed and compared to those calculated with a simulation program. The possible temperature lift between heat source and heat sink depending on the achievable COP are presented.

  13. On the development of high temperature ammonia-water hybrid absorption-compression heat pumps

    DEFF Research Database (Denmark)

    Jensen, Jonas Kjær; Markussen, Wiebke Brix; Reinholdt, Lars;

    2015-01-01

    Ammonia-water hybrid absorption-compression heat pumps (HACHP) are a promising technology for development of ecient high temperature industrial heat pumps. Using 28 bar components HACHPs up to 100 °C are commercially available. Components developed for 50 bar and 140 bar show that these pressure ......, and 140 bar up to 147 °C. If the compressor discharge temperature limit is increased to 250 °C and the vapour water content constraint is removed, this becomes: 182 °C, 193 °C and 223 °C....

  14. Groundwater heat pumps with turbines for the return water; Grundwasser-Waermepumpe mit Rueckgabe-Turbinierung

    Energy Technology Data Exchange (ETDEWEB)

    Eberhard, M.

    2007-09-15

    This final report for the Swiss Federal Office of Energy (SFOE) reports on improvements in the efficiency of a ground water heat pump installation in an office building. The water return well was equipped with a turbine. In this installation, the ground water is pumped up from a depth of 45 meters which means that a lot of electricity is needed for the pumping of the water. Coefficients of performance of the system are quoted for the situation with and without the turbine. The conversion of a pump for use as a turbine is commented on. The construction of a specially developed turbine with reduced electricity consumption is suggested. Seasonal performance data of the system is provided in tabular form.

  15. Analysis of air-to-water heat pump in cold climate: comparison between experiment and simulation

    Directory of Open Access Journals (Sweden)

    Karolis Januševičius

    2015-10-01

    Full Text Available Heat pump systems are promising technologies for current and future buildings and this research presents the performance of air source heat pump (ASHP system. The system was monitored, analysed and simulated using TRNSYS software. The experimental data were used to calibrate the simulation model of ASHP. The specific climate conditions are evaluated in the model. It was noticed for the heating mode that the coefficient of performance (COP varied from 1.98 to 3.05 as the outdoor temperature changed from –7.0 ºC to +5.0 ºC, respectively. TRNSYS simulations were also performed to predict seasonal performance factor of the ASHP for Vilnius city. It was identified that seasonal performance prediction could be approximately 15% lower if frost formation effects are not included to air-water heat pump simulation model.

  16. Regenerative Hydride Heat Pump

    Science.gov (United States)

    Jones, Jack A.

    1992-01-01

    Hydride heat pump features regenerative heating and single circulation loop. Counterflow heat exchangers accommodate different temperatures of FeTi and LaNi4.7Al0.3 subloops. Heating scheme increases efficiency.

  17. Regenerative Hydride Heat Pump

    Science.gov (United States)

    Jones, Jack A.

    1992-01-01

    Hydride heat pump features regenerative heating and single circulation loop. Counterflow heat exchangers accommodate different temperatures of FeTi and LaNi4.7Al0.3 subloops. Heating scheme increases efficiency.

  18. Development of High Efficiency Carbon Dioxide Commercial Heat Pump Water Heater

    Energy Technology Data Exchange (ETDEWEB)

    Michael PETERSEN; Chad D. BOWERS; Stefan ELBEL; Pega HRNJAK

    2012-07-01

    Although heat pump water heaters are today widely accepted in both Japan and Europe, where energy costs are high and government incentives for their use exist, acceptance of such products in the US has been limited. While this trend is slowly changing with the introduction of heat pump water heaters into the residential market, but acceptance remains low in the commercial sector. The objective of the presented work is the development of a high efficiency R744 heat pump water heater for commercial applications with effective utilization of the cooling capability for air conditioning and/or refrigeration. The ultimate goal is to achieve total system COP of up to 8. This unit will be targeted at commercial use where some cooling load is typically needed year round, such as restaurants, hotels, nursing homes, and hospitals. This paper presents the performance results from the development of four R744 commercial heat pump water heater packages of approximately 35 kW and comparison to a commercially available baseline R134a unit of the same capacity and footprint. In addition, the influences of an internal heat exchanger and an enhanced evaporator on the system performance are described and recommendations are made for further improvements of the R744 system.

  19. Energy Efficiency Modelling of Residential Air Source Heat Pump Water Heater

    Directory of Open Access Journals (Sweden)

    Cong Toan Tran

    2016-03-01

    Full Text Available The heat pump water heater is one of the most energy efficient technologies for heating water for household use. The present work proposes a simplified model of coefficient of performance and examines its predictive capability. The model is based on polynomial functions where the variables are temperatures and the coefficients are derived from the Australian standard test data, using regression technics. The model enables to estimate the coefficient of performance of the same heat pump water heater under other test standards (i.e. US, Japanese, European and Korean standards. The resulting estimations over a heat-up phase and a full test cycle including a draw off pattern are in close agreement with the measured data. Thus the model allows manufacturers to avoid the need to carry out physical tests for some standards and to reduce product cost. The limitations of the methodology proposed are also discussed.

  20. Energy Savings and Breakeven Cost for Residential Heat Pump Water Heaters in the United States

    Energy Technology Data Exchange (ETDEWEB)

    Maguire, J.; Burch, J.; Merrigan, T.; Ong, S.

    2013-07-01

    Heat pump water heaters (HPWHs) have recently reemerged in the U.S. residential water heating market and have the potential to provide homeowners with significant energy savings. However, there are questions as to the actual performance and energy savings potential of these units, in particular in regards to the heat pump's performance in unconditioned space and the impact of the heat pump on space heating and cooling loads when it is located in conditioned space. To help answer these questions, simulations were performed of a HPWH in both conditioned and unconditioned space at over 900 locations across the continental United States and Hawaii. Simulations included a Building America benchmark home so that any interaction between the HPWH and the home's HVAC equipment could be captured. Comparisons were performed to typical gas and electric water heaters to determine the energy savings potential and cost effectiveness of a HPWH relative to these technologies. HPWHs were found to have a significant source energy savings potential when replacing typical electric water heaters, but only saved source energy relative to gas water heater in the most favorable installation locations in the southern US. When replacing an electric water heater, the HPWH is likely to break even in California, the southern US, and parts of the northeast in most situations. However, the HPWH will only break even when replacing a gas water heater in a few southern states.

  1. Energy Savings and Breakeven Costs for Residential Heat Pump Water Heaters in the United States

    Energy Technology Data Exchange (ETDEWEB)

    Maguire, Jeff [National Renewable Energy Lab. (NREL), Golden, CO (United States); Burch, Jay [National Renewable Energy Lab. (NREL), Golden, CO (United States); Merrigan, Tim [National Renewable Energy Lab. (NREL), Golden, CO (United States); Ong, Sean [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2013-07-01

    Heat pump water heaters (HPWHs) have recently re-emerged in the U.S. residential water heating market and have the potential to provide homeowners with significant energy savings. However, there are questions as to the actual performance and energy savings potential of these units, in particular in regards to the heat pump's performance in unconditioned space and the impact of the heat pump on space heating and cooling loads when it is located in conditioned space. To help answer these questions, NREL performed simulations of a HPWH in both conditioned and unconditioned space at over 900 locations across the continental United States and Hawaii. Simulations included a Building America benchmark home so that any interaction between the HPWH and the home's HVAC equipment could be captured. Comparisons were performed to typical gas and electric water heaters to determine the energy savings potential and cost effectiveness of a HPWH relative to these technologies. HPWHs were found to have a significant source energy savings potential when replacing typical electric water heaters, but only saved source energy relative to gas water heater in the most favorable installation locations in the southern United States. When replacing an electric water heater, the HPWH is likely to break even in California, the southern United States, and parts of the northeast in most situations. However, the HPWH will only break even when replacing a gas water heater in a few southern states.

  2. Numerical and experimental study on heat pump water heater with PCM for thermal storage

    Energy Technology Data Exchange (ETDEWEB)

    Long, Jian-You; Zhu, Dong-Sheng [Key Laboratory of Enhanced Heat Transfer and Energy Conservation of the Ministry of Education, Academy of Chemistry and Energy, South China University of Technology, Guangzhou, Guangdong 510640 (China)

    2008-07-01

    An air source heat pump water heater with phase change material (PCM) for thermal storage was designed to take advantage of off-peak electrical energy. The heat transfer model of PCM was based upon a pure conduction formulation. Quasi-steady state method was used to calculate the temperature distribution and phase front location of PCM during thermal storage process. Temperature and thermal resistance iteration approach has been developed for the analysis of temperature variation of heat transfer fluid (HTF) and phase front location of PCM during thermal release process. To test the physical validity of the calculational results, experimental studies about storing heat and releasing heat of PCM were carried. Comparison between the calculational results and the experimental data shows good agreement. Graphical results including system pressure and input power of heat pump, time-wise variation of stored and released thermal energy of PCM were presented and discussed. (author)

  3. Summer Indoor Heat Pump Water Heater Evaluation in a Hot-Dry Climate

    Energy Technology Data Exchange (ETDEWEB)

    Hoeschele, Marc [Alliance for Residential Building Innovation (ARBI), Davis, CA (United States); Seitzler, Matthew [Alliance for Residential Building Innovation (ARBI), Davis, CA (United States)

    2017-05-01

    Heat pump water heaters offer a significant opportunity to improve water heating performance for the over 40% of U.S. households that heat domestic hot water using electric resistance storage water heaters. Numerous field studies have also been completed documenting performance in a variety of climates and applications. More recent evaluation efforts have focused attention on the performance of May through September 2014, with ongoing winter monitoring being sponsored by California utility partners. Summer results show favorable system performance with extrapolated annual water heating savings of 1,466 to 2,300 kWh per year, based on the observed hot water loads. Additional summer space cooling benefits savings of 121 to 135 kWh per year were projected, further increasing the water energy savings.

  4. Hydride heat pump with heat regenerator

    Science.gov (United States)

    Jones, Jack A. (Inventor)

    1991-01-01

    A regenerative hydride heat pump process and system is provided which can regenerate a high percentage of the sensible heat of the system. A series of at least four canisters containing a lower temperature performing hydride and a series of at least four canisters containing a higher temperature performing hydride is provided. Each canister contains a heat conductive passageway through which a heat transfer fluid is circulated so that sensible heat is regenerated. The process and system are useful for air conditioning rooms, providing room heat in the winter or for hot water heating throughout the year, and, in general, for pumping heat from a lower temperature to a higher temperature.

  5. High efficient ammonia heat pump system for industrial process water using the ISEC concept. Part 2

    DEFF Research Database (Denmark)

    Olesen, Martin F.; Madsen, Claus; Olsen, Lars

    2014-01-01

    The Isolated System Energy Charging (ISEC) concept allows for a high efficiency of a heat pump system for hot water production. The ISEC concept consists of two water storage tanks, one charged and one discharged. The charged tank is used for the industrial process, while the discharged tank...... modelling of the heat pump and tank system is performed (in continuation of Part I). The modelling is extended to include the system performance with different natural refrigerants and the influence of different types of compressors....... is charging. The charging of the tank is done by recirculating water through the condenser and thereby gradually heating the water. The modelling of the system is described in Part I [1]. In this part, Part II, an experimental test setup of the tank system is reported, the results are presented and further...

  6. Possibility of Heat Pump Use in Hot Water Supply Systems

    Directory of Open Access Journals (Sweden)

    Tatyana Babak

    2016-09-01

    The results of this work may be used for in Total Site methodology development allowing heat recovery for district heating needs of both new designs and as retrofits to existing sites to ensure fast, widespread and cost-efficient industrial deployment. It leads to carbon footprint reduction and energy efficiency improvement of regions with heating and cooling demands during winter and summer seasons.

  7. Measure Guideline. Heat Pump Water Heaters in New and Existing Homes

    Energy Technology Data Exchange (ETDEWEB)

    Shapiro, Carl [Consortium for Advanced Residential Buildings (CARB), Norwalk, CT (United States); Puttagunta, Srikanth [Consortium for Advanced Residential Buildings (CARB), Norwalk, CT (United States); Owens, Douglas [Consortium for Advanced Residential Buildings (CARB), Norwalk, CT (United States)

    2012-02-01

    This Building America Measure Guideline is intended for builders, contractors, homeowners, and policy-makers. This document is intended to explore the issues surrounding heat pump water heaters (HPWHs) to ensure that homeowners and contractors have the tools needed to appropriately and efficiently install HPWHs

  8. 10 CFR 431.107 - Uniform test method for the measurement of energy efficiency of commercial heat pump water...

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 3 2010-01-01 2010-01-01 false Uniform test method for the measurement of energy efficiency of commercial heat pump water heaters. 431.107 Section 431.107 Energy DEPARTMENT OF ENERGY ENERGY... method for the measurement of energy efficiency of commercial heat pump water heaters. Energy...

  9. Absorption heat pump system

    Science.gov (United States)

    Grossman, G.

    1982-06-16

    The efficiency of an absorption heat pump system is improved by conducting liquid from a second stage evaporator thereof to an auxiliary heat exchanger positioned downstream of a primary heat exchanger in the desorber of the system.

  10. High Temperature Thermoacoustic Heat Pump

    Energy Technology Data Exchange (ETDEWEB)

    Tijani, H.; Spoelstra, S. [ECN Biomass and Energy Efficiency, Petten (Netherlands)

    2012-07-15

    Thermoacoustic technology can provide new types of heat pumps that can be deployed in different applications. Thermoacoustic heat pumps can for example be applied in dwellings to generate cooling or heating. Typically, space and water heating makes up about 60% of domestic and office energy consumption. The application of heat pumps can contribute to achieve energy savings and environmental benefits by reducing CO2 and NOx emissions. This paper presents the study of a laboratory scale thermoacoustic-Stirling heat pump operating between 10C and 80C which can be applied in domestics and offices. The heat pump is driven by a thermoacoustic-Stirling engine. The experimental results show that the heat pump pumps 250 W of heat at 60C at a drive ratio of 3.6 % and 200 W at 80C at a drive ratio of 3.5 %. The performance for both cases is about 40% of the Carnot performance. The design, construction, and performance measurements of the heat pump will be presented and discussed.

  11. Design of serially connected ammonia-water hybrid absorption-compression heat pumps for district heating with the utilisation of a geothermal heat source

    DEFF Research Database (Denmark)

    Jensen, Jonas Kjær; Ommen, Torben Schmidt; Markussen, Wiebke Brix;

    2016-01-01

    District heating (DH) can reduce the primary energy consumption in urban areas with significant heat demands. The design of a serially connected ammonia-water hybrid absorption-compression heat pump system was investigated for operation in the Greater Copenhagen DH network in Denmark, in order...... to supply 7.2 MW heat at 85 °C utilizing a geothermal heat source at 73 °C. Both the heat source and heat sink experience a large temperature change over the heat transfer process, of which a significant part may be achieved by direct heat exchange. First a generic study with a simple representation...

  12. Optimization and thermoeconomics research of a large reclaimed water source heat pump system.

    Science.gov (United States)

    Zhang, Zi-ping; Du, Fang-hui

    2013-01-01

    This work describes a large reclaimed water source heat pump system (RWSHPS) and elaborates on the composition of the system and its design principles. According to the characteristics of the reclaimed water and taking into account the initial investment, the project is divided into two stages: the first stage adopts distributed heat pump heating system and the second adopts the combination of centralized and decentralized systems. We analyze the heating capacity of the RWSHPS, when the phase II project is completed, the system can provide hydronic heating water with the supply and return water temperature of 55°C/15°C and meet the hydronic heating demand of 8 million square meters of residential buildings. We make a thermal economics analysis by using Thermal Economics theory on RWSHPS and gas boiler system, it is known that the RWSHPS has more advantages, compared with the gas boiler heating system; both its thermal efficiency and economic efficiency are relatively high. It provides a reference for future applications of the RWSHPS.

  13. Research on a Household Dual Heat Source Heat Pump Water Heater with Preheater Based on ASPEN PLUS

    Directory of Open Access Journals (Sweden)

    Xiang Gou

    2016-12-01

    Full Text Available This article proposes a dual heat source heat pump bathroom unit with preheater which is feasible for a single family. The system effectively integrates the air source heat pump (ASHP and wastewater source heat pump (WSHP technologies, and incorporates a preheater to recover shower wastewater heat and thus improve the total coefficient of performance (COP of the system, and it has no electric auxiliary heating device, which is favorable to improve the security of the system operation. The process simulation software ASPEN PLUS, widely used in the design and optimization of thermodynamic systems, was used to simulate various cases of system use and to analyze the impact of the preheater on the system. The average COP value of a system with preheater is 6.588 and without preheater it is 4.677. Based on the optimization and analysis, under the standard conditions of air at 25 °C, relative humidity of 70%, wastewater at 35 °C, wastewater flow rate of 0.07 kg/s, tap water at 15 °C, and condenser outlet water temperature at 50 °C, the theoretical COP of the system can reach 9.784 at an evaporating temperature of 14.96 °C, condensing temperature of 48.74 °C, and preheated water temperature of 27.19 °C.

  14. Quantifying Systemic Efficiency using Exergy and Energy Analysis for Ground Source Heat Pumps: Domestic Space Conditioning and Water Heating Applications.

    Energy Technology Data Exchange (ETDEWEB)

    Ally, Moonis Raza [ORNL; Baxter, Van D [ORNL; Gehl, Anthony C [ORNL; Munk, Jeffrey D [ORNL

    2017-01-01

    Although air temperatures over land surfaces show wide seasonal and daily variations, the ground, approximately 10 meters below the earth s surface, remains relatively stable in temperature thereby serving as an energy source or sink. Ground source heat pumps can heat, cool, and supply homes with hot water efficiently by utilizing the earth s renewable and essentially inexhaustible energy resources, saving fossil fuels, reducing greenhouse gas emissions, and lowering the environmental footprint. In this paper, evidence is shown that ground source heat pumps can provide up to 79%-87% of domestic hot water energy needs, and up to 77% of space heating needs with the ground s thermal energy resources. The case refers to a 12-month study conducted at a 253 m2 research house located in Oak Ridge, Tennessee, 36.01 N 84.26 W in a mixed-humid climate with HDD of 2218 C-days and CDD of 723 C-days under simulated occupancy conditions. A single 94.5m vertical bore interfaced the heat pump with the ground. The research shows that this technology is capable of achieving US DOE targets of 25 % and 35% energy savings in HVAC, and in water heating, respectively by 2030. It is also a viable technology to meet greenhouse gas target emissions under the IECC 2012 Standard, as well as the European Union (EU) 2020 targets of using renewable energy resources. The paper quantifies systemic efficiencies using Exergy analysis of the major components, clearly pointing areas for further improvement.

  15. Performance Analysis of Air-to-Water Heat Pump in Latvian Climate Conditions

    Science.gov (United States)

    Kazjonovs, Janis; Sipkevics, Andrejs; Jakovics, Andris; Dancigs, Andris; Bajare, Diana; Dancigs, Leonards

    2014-12-01

    Strategy of the European Union in efficient energy usage demands to have a higher proportion of renewable energy in the energy market. Since heat pumps are considered to be one of the most efficient heating and cooling systems, they will play an important role in the energy consumption reduction in buildings aimed to meet the target of nearly zero energy buildings set out in the EU Directive 2010/31/EU. Unfortunately, the declared heat pump Coefficient of Performance (COP) corresponds to a certain outdoor temperature (+7 °C), therefore different climate conditions, building characteristics and settings result in different COP values during the year. The aim of this research is to investigate the Seasonal Performance factor (SPF) values of air-to-water heat pump which better characterize the effectiveness of heat pump in a longer selected period of time, especially during the winter season, in different types of residential buildings in Latvian climate conditions. Latvia has four pronounced seasons of near-equal length. Winter starts in mid-December and lasts until mid-March. Latvia is characterized by cold, maritime climate (duration of the average heating period being 203 days, the average outdoor air temperature during the heating period being 0.0 °C, the coldest five-day average temperature being -20.7 °C, the average annual air temperature being +6.2 °C, the daily average relative humidity being 79 %). The first part of this research consists of operational air-towater heat pump energy performance monitoring in different residential buildings during the winter season. The second part of the research takes place under natural conditions in an experimental construction stand which is located in an urban environment in Riga, Latvia. The inner area of this test stand, where air-to-water heat pump performance is analyzed, is 9 m2. The ceiling height is 3 m, all external wall constructions (U = 0.16 W/(m2K)) have ventilated facades. To calculate SPF, the

  16. Measure Guideline: Heat Pump Water Heaters in New and Existing Homes

    Energy Technology Data Exchange (ETDEWEB)

    Shapiro, C.; Puttagunta, S.; Owens, D.

    2012-02-01

    This Building America Measure Guideline is intended for builders, contractors, homeowners, and policy-makers. This document is intended to explore the issues surrounding heat pump water heaters (HPWHs) to ensure that homeowners and contractors have the tools needed to appropriately and efficiently install HPWHs. Heat pump water heaters (HPWHs) promise to significantly reduce energy consumption for domestic hot water (DHW) over standard electric resistance water heaters (ERWHs). While ERWHs perform with energy factors (EFs) around 0.9, new HPWHs boast EFs upwards of 2.0. High energy factors in HPWHs are achieved by combining a vapor compression system, which extracts heat from the surrounding air at high efficiencies, with electric resistance element(s), which are better suited to meet large hot water demands. Swapping ERWHs with HPWHs could result in roughly 50% reduction in water heating energy consumption for 35.6% of all U.S. households. This Building America Measure Guideline is intended for builders, contractors, homeowners, and policy-makers. While HPWHs promise to significantly reduce energy use for DHW, proper installation, selection, and maintenance of HPWHs is required to ensure high operating efficiency and reliability. This document is intended to explore the issues surrounding HPWHs to ensure that homeowners and contractors have the tools needed to appropriately and efficiently install HPWHs. Section 1 of this guideline provides a brief description of HPWHs and their operation. Section 2 highlights the cost and energy savings of HPWHs as well as the variables that affect HPWH performance, reliability, and efficiency. Section 3 gives guidelines for proper installation and maintenance of HPWHs, selection criteria for locating HPWHs, and highlights of important differences between ERWH and HPWH installations. Throughout this document, CARB has included results from the evaluation of 14 heat pump water heaters (including three recently released HPWH

  17. Hot water preparation with heat pumps; Warmwasserbereitung mit Waermepumpe. Messungen an einer Anlage in Rorschacherberg

    Energy Technology Data Exchange (ETDEWEB)

    Mayer, H.; Gabathuler, H. R. [Gabathuler AG, Beratende Ingenieure, Diessenhofen (Switzerland); Baumgartner, Th. [Th. Baumgartner and Partner AG, Duebendorf (Switzerland)

    2007-07-15

    This final report for the Swiss Federal Office of Energy (SFOE) presents the results of measurements made on an installation in Rorschacherberg, Switzerland. The paper examines the results obtained as a result of implementing recommendations for designing domestic hot water heating systems using heat pumps. These were published in the STASCH project on standard circuit diagrams for small-scale heat pump plants. The effectiveness of these recommendations was investigated in this project. Furthermore, optimum hydraulic circuits and control procedures were developed based on measurements made on the experimental plant in Rorschacherberg. The installation examined is described and commented on. Six configuration variants conforming to the STASCH concept are examined and operational aspects are commented on. Finally, recommendations on temperatures and operational modi are made.

  18. District Heating System Using Heat Pump Installations and CHP

    Directory of Open Access Journals (Sweden)

    Sit M.L.

    2015-12-01

    Full Text Available The article describes the district heating system, in which part of the heat of return water thermal power is used to supply heat to the district heating puThe article describes the district heating system, in which part of the heat of return water thermal power is used to supply heat to the district heating pumps, evaporators heating and hot water. Heat pumps use carbon dioxide as refrigerant. During the transitional period of the year, and the summer heat pump for preparing hot-water supply system uses the heat of the surrounding air. The heat of the ambient air is used in the intermediate heat exchanger between the first and second stages of the heat pump to cool the gas after the first stage of the compressor of the heat pump.

  19. Development of Absorption Heat Pump Driven by Low Temperature Hot Water

    Science.gov (United States)

    Hoshida, Toshihiro; Nakamura, Naoto; Asai, Hiroshi; Hasatani, Masanobu; Watanabe, Fujio; Fujisawa, Ryou

    We developed an Adsorption Heat Pump (AHP) system, which applies silica-gel as adsorbent and H2O as refrigerant, and is possibly intended to use low temperature hot water (333K) as a driving force. The growing importance to save energy, leads us to develop energy saving systems such as Co-generation systems, including fuel cell system. It is important to use low temperature hot water in order to achieve high efficiency in total. It is, however, noticed that the lower water temperature is, the more difficult its' heat recovery becomes. We reported experimental results of the AHP system, and estimated the possibility to apply low temperature hot water from fuel cell system to the AHP system. We showed quantitatively that the AHP system is able to be driven by low temperature hot water(333K).

  20. Heat Pump Water Heater Ducting Strategies with Encapsulated Attics in Climate Zones 2 and 4

    Energy Technology Data Exchange (ETDEWEB)

    Sweet, M. L. [Southface Energy Inst., Atlanta, GA (United States); Francisco, A. [Southface Energy Inst., Atlanta, GA (United States); Roberts, S. G. [Southface Energy Inst., Atlanta, GA (United States)

    2016-05-01

    The focus of this study is on the performance of HPWHs with several different duct configurations and their effects on whole building heating, cooling, and moisture loads. A.O. Smith 60 gallon Voltex (PHPT-60) heat pump water heaters (HPWHs) were included at two project sites and ducted to or located within spray foamed encapsulated attics. The effect of ducting a HPWH's air stream does not diminish its efficiency if the ducting does not reduce intake air temperature, which expands HPWH application to confined areas.

  1. Building America Case Study: Indoor Heat Pump Water Heaters During Summer in a Hot-Dry Climate, Redding, California

    Energy Technology Data Exchange (ETDEWEB)

    M. Hoeschele, M. Seitzler

    2017-06-01

    Heat pump water heaters offer a significant opportunity to improve water heating performance for the over 40% of U.S. households that heat domestic hot water using electric resistance storage water heaters. Numerous field studies have also been completed documenting performance in a variety of climates and applications. More recent evaluation efforts have focused attention on the performance of May through September 2014, with ongoing winter monitoring being sponsored by California utility partners.

  2. Development and application of engineering-scale solar water heater system assisted by heat pump

    Energy Technology Data Exchange (ETDEWEB)

    Gao Xiufeng; Feng Shiyu; Hu Wei; Zheng Feifei [Xi' an Jiaotong Univ., Xi' an (China); Wang Huiyu; Luo Cong [Yangzhou Sunleada Co, Ltd, Yangzhou (China); Wang Jianguo; Fan Guiyou [TongLing Real Estate Co. Ltd, TongLing (China)

    2008-07-01

    An engineering-scale solar water heater system assisted by heat pump was developed based on a modularized structure. The subunits of modularized system include vacuum solar energy collectors, air source heat pump, heat storage and supplying system and control panel. All devices could be controlled and monitored centrally. Energy source of this system was composed of solar energy (70%), air thermal energy (20%) and electric power (10%). The system has advantages of high average annual comprehensive energy efficiency and elementary energy utilization efficiency. The product can be employed in central heat water supplying project with a capacity of more than 6 ton, in such facilities as residential districts, hotels, restaurants, dormitories, bathing centers and so on. The economical efficiency is better as the scale is bigger. The project has been supported by innovation funds of Science and Technology of Chinese Ministry of Science and Technology (MOST), being applied in a residential district successfully as a demonstration project of renewable and new energy by Chinese Ministry of Construction. (orig.)

  3. High Efficiency Water Heating Technology Development Final Report, Part II: CO2 and Absorption-Based Residential Heat Pump Water Heater Development

    Energy Technology Data Exchange (ETDEWEB)

    Gluesenkamp, Kyle R. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Abdelaziz, Omar [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Patel, Viral K. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Mandel, Bracha T. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); de Almeida, Valmor F. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2017-05-01

    The two objectives of this project were to 1.demonstrate an affordable path to an ENERGY STAR qualified electric heat pump water heater (HPWH) based on low-global warming potential (GWP) CO2 refrigerant, and 2.demonstrate an affordable path to a gas-fired absorption-based heat pump water heater with a gas energy factor (EF) greater than 1.0. The first objective has been met, and the project has identified a promising low-cost option capable of meeting the second objective. This report documents the process followed and results obtained in addressing these objectives.

  4. Chiral brownian heat pump.

    Science.gov (United States)

    van den Broek, M; Van den Broeck, C

    2008-04-04

    We present the exact analysis of a chiral Brownian motor and heat pump. Optimization of the construction predicts, for a nanoscale device, frequencies of the order of kHz and cooling rates of the order of femtojoule per second.

  5. Chiral Brownian heat pump

    OpenAIRE

    Van Den Broek, Martijn; Van Den Broeck, Christian

    2007-01-01

    We present the exact analysis of a chiral Brownian motor and heat pump. Optimization of the construction predicts, for a nanoscale device, frequencies of the order of kHz and cooling rates of the order of femtojoule per second.

  6. Carbon dioxide as refrigerant for tap water heat pumps: A comparison with the traditional solution

    Energy Technology Data Exchange (ETDEWEB)

    Cecchinato, Luca; Corradi, Marco; Fornasieri, Ezio; Zamboni, Lorenzo [Dipartimento di Fisica Tecnica, Universita degli Studi di Padova, Via Venezia, 1 I-35131 Padova (Italy)

    2005-12-01

    Increased concern about the environmental impact of the refrigeration technology is leading toward design solutions aimed at improving the energy efficiency of the related applications, using eco-friendly refrigerants, i.e. ozone-friendly and with the least possible global warming potential (GWP). In this respect, carbon dioxide (ASHRAE R744) is seen today as one of the most promising refrigerants and is raising great interest in industrial and scientific fields. In the present work, the plant options are investigated, which are related to the design of air/water heat pumps for tap water using CO{sub 2}. A comparison is made, in terms of energy efficiency, between a system working with CO{sub 2} and a similar one working with HFC R134a; such a comparison is carried out by means of a simulation model of a refrigerating machine/heat pump, characterized by a detailed representation of the heat exchangers, based on their subdivision into elementary volumes. Results show that carbon dioxide is an interesting substitute for synthetic fluids, if the design of the system is focused to take advantage of its properties. (author)

  7. Improved Design Tools for Surface Water and Standing Column Well Heat Pump Systems (DE-EE0002961)

    Energy Technology Data Exchange (ETDEWEB)

    Spitler, J. D.; Culling, J. R.; Conjeevaram, K.; Ramesh, M.; Selvakumar, M.

    2012-11-30

    Ground-source heat pump (GSHP) systems are perhaps the most widely used “sustainable” heating and cooling systems, with an estimated 1.7 million installed units with total installed heating capacity on the order of 18 GW. They are widely used in residential, commercial, and institutional buildings. Standing column wells (SCW) are one form of ground heat exchanger that, under the right geological conditions, can provide excellent energy efficiency at a relatively low capital cost. Closed-loop surface water heat pump (SWHP) systems utilize surface water heat exchangers (SWHE) to reject or extract heat from nearby surface water bodies. For building near surface water bodies, these systems also offer a high degree of energy efficiency at a low capital cost. However, there have been few design tools available for properly sizing standing column wells or surface water heat exchangers. Nor have tools for analyzing the energy consumption and supporting economics-based design decisions been available. The main contributions of this project lie in providing new tools that support design and energy analysis. These include a design tool for sizing surface water heat exchangers, a design tool for sizing standing column wells, a new model of surface water heat pump systems implemented in EnergyPlus and a new model of standing column wells implemented in EnergyPlus. These tools will better help engineers design these systems and determine the economic and technical feasibility.

  8. Investment and Economy Analysis of Water-Source Heat Pump System in Chongqing, China

    Directory of Open Access Journals (Sweden)

    Yong Ding

    2013-01-01

    Full Text Available In China, the application of renewable energy witnesses rapid development. In the near future, a lot of demonstration projects will be built and thus it is urgent to know the economics of renewable energy building application technologies. Based on the renewable energy demonstration projects in Chongqing city, the author discussed the economy issue of water-source heat pump system (WSHPs in order to provide suggestions for the application projects. According to the design information of demonstration projects, the average incremental investment, allowance, and payback period are calculated in this paper. Comparing WSHPs with traditional heating, ventilation, and air conditioning (HVAC system, the saved energy of WSHPs is estimated in the current paper. The author calculated the amount of saved energy in unit applied area and unit intake water. Besides, the economy and efficiency of WSHPs project is analyzed at the end of this paper.

  9. Optimized ground coupled heat pump mechanical package

    Energy Technology Data Exchange (ETDEWEB)

    Catan, M.A.

    1987-01-01

    This project addresses the question of how well a ground coupled heat pump system could perform with a heat pump which was designed specifically for such systems operating in a northern climate. Conventionally, systems are designed around water source heat pumps which are not designed for ground coupled heat pump application. The objective of the project is to minimize the life cycle cost for a ground coupled system given the freedom to design the heat pump and the ground coil in concert. In order to achieve this objective a number of modeling tools were developed which will likely be of interest in their own right.

  10. Cold Climate Heat Pump

    Science.gov (United States)

    2013-08-01

    12. Data set 7 – energy consumption of heat pump and furnace ................................ 22 Figure 13. Experimentally adjusted TRNSYS model...minute SCF standard cubic feet SEER seasonal energy efficiency ratio SH superheated TMY Typical Meteorological Year TRNSYS Transient Systems...Simulation Program ( TRNSYS ), to generate an experimentally adjusted, simulation heating seasonal performance. 6.4.1 Simulation Results The TRNSYS model

  11. Heat pump planning handbook

    CERN Document Server

    Bonin, Jürgen

    2015-01-01

    The Heat Pump Planning Handbook contains practical information and guidance on the design, planning and selection of heat pump systems, allowing engineers, designers, architects and construction specialists to compare a number of different systems and options. Including detailed descriptions of components and their functions and reflecting the current state of technology this guide contains sample tasks and solutions as well as new model calculations and planning evaluations. Also economic factors and alternative energy sources are covered, which are essential at a time of rising heat costs. T

  12. Sorption product heat pump

    Energy Technology Data Exchange (ETDEWEB)

    Antonini, G.; Francois, O.; Gendarme, J.P.; Guilleminot, J.J.; Meunier, F.

    1988-07-15

    A continuous operating, and thus with enhanced performance, heat pump is presented. In this heat pump, the heat transfer between the hot source and the output system or network is realized through a solid adsorbent-refrigerant couple having endothermal desorption properties and exothermal adsorption or absorption properties. The sorption products are carried in a closed cycle movement between the two parts of the reactor. Each side of the reactor is assuming always the same function and the thermal inertia have to be overcome only when starting the reactor.

  13. Molecular heat pump.

    Science.gov (United States)

    Segal, Dvira; Nitzan, Abraham

    2006-02-01

    We propose a molecular device that pumps heat against a thermal gradient. The system consists of a molecular element connecting two thermal reservoirs that are characterized by different spectral properties. The pumping action is achieved by applying an external force that periodically modulates molecular levels. This modulation affects periodic oscillations of the internal temperature of the molecule and the strength of its coupling to each reservoir resulting in a net heat flow in the desired direction. The heat flow is examined in the slow and fast modulation limits and for different modulation wave forms, thus making it possible to optimize the device performance.

  14. Ground-water heat pumps: an examination of hydrogeologic, environmental, legal, and economic factors affecting their use

    Energy Technology Data Exchange (ETDEWEB)

    Armitage, D M; Bacon, D J; Massey-Norton, J T; Miller, J D

    1980-11-12

    Groundwater is attractive as a potential low-temperature energy source in residential space-conditioning applications. When used in conjuncton with a heat pump, ground water can serve as both a heat source (for heating) and a heat sink (for cooling). Major hydrogeologic aspects that affect system use include groundwater temperature and availability at shallow depths as these factors influence operational efficiency. Ground-water quality is considered as it affects the performance and life-expectancy of the water-side heat exchanger. Environmental impacts related to groundwater heat pump system use are most influenced by water use and disposal methods. In general, recharge to the subsurface (usually via injection wells) is recommended. Legal restrictions on system use are often stricter at the municipal and county levels than at state and Federal levels. Although Federal regulations currently exist, the agencies are not equipped to regulate individual, domestic installations. Computer smulations indicate that under a variety of climatologic conditions, groundwater heat pumps use less energy than conventional heating and cooling equipment. Life-cycle cost comparisons with conventional equipment depend on alternative system choices and well cost options included in the groundwater heat pump system.

  15. Heat pumps in agricultural uses. Factsheet

    Energy Technology Data Exchange (ETDEWEB)

    MacDonald, R.D.

    1986-04-01

    This paper provides an elementary introduction to heat pumps and their potential for use in Ontario agricultural applications, taking into account local climatic conditions which mean high heating loads and small cooling loads. A heat pump's ability to remove heat from a variety of sources and boost this heat to a useable temperature enables such farm uses as recovery of heat from exhaust air in livestock barns, greenhouse heating using ground water, and heat extraction from manure. Basic types of heat pumps are evaluated and compared, and their costs are estimated.

  16. The integration of water loop heat pump and building structural thermal storage systems

    Energy Technology Data Exchange (ETDEWEB)

    Marseille, T.J.; Schliesing, J.S.

    1991-10-01

    Many commercial buildings need heat in one part and, at the same time, cooling in another part. Even more common is the need for heating during one part of the day and cooling during another in the same spaces. If that energy could be shifted or stored for later use, significant energy might be saved. If a building's heating and cooling subsystems could be integrated with the building's structural mass and used to collect, store, and deliver energy, the energy might be save cost-effectively. To explore this opportunity, researchers at the Pacific Northwest Laboratory (PNL) examined the thermal interactions between the heating, ventilating, and air-conditioning (HVAC) system and the structure of a commercial building. Computer models were developed to simulate the interactions in an existing building located in Seattle, Washington, to determine how these building subsystems could be integrated to improve energy efficiency. The HVAC subsystems in the existing building were modeled. These subsystems consist of decentralized water-source heat pumps (WSHP) in a closed water loop, connected to cooling towers for heat rejection during cooling mode and boilers to augment heating. An initial base case'' computer model of the Seattle building, as-built, was developed. Metered data available for the building were used to calibrate this model to ensure that the analysis would provide information that closely reflected the operation of a real building. The HVAC system and building structure were integrated in the model using the concrete floor slabs as thermal storage media. The slabs may be actively charged during off-peak periods with the chilled water in the loop and then either actively or passively discharged into the conditioned space during peak periods. 21 refs., 37 figs., 17 tabs.

  17. Heat pump using dual heat sources of air and water. Performance with heat sources arranged in parallel; Mizu kuki ryonetsugen heat pump no kenkyu. Netsugen heiretsu unten ni okeru seino

    Energy Technology Data Exchange (ETDEWEB)

    Ito, S.; Miura, N.; Sato, S. [Kanagawa Institute of Technology, Kanagawa (Japan); Uchikawa, Y.; Hamada, K. [Kubota Corp., Osaka (Japan)

    1996-10-27

    A heat pump system using water and air as heat sources was built and evaluated for its performance. In this system, evaporators may be operated singly or as connected in parallel or series, and, for each case, the quantity of heat acquired may be measured and system performance may be quantitatively evaluated. The findings follow. When the two heat sources are equal in temperature in the single-evaporator operation, the evaporation temperature is about 7{degree}C higher on the water side than on the air side, and the performance coefficient is about 0.7 higher. When the air heat source temperature is 25{degree}C in the parallel operation, like quantities of heat are obtained from both heat sources, and collection of heat from the water increases with a decrease in the air heat source temperature but, with an increase, collection from the air increases. When the air heat source temperature decreases, the evaporation temperature decreases in the single-evaporator working on the air and in the parallel operation but it levels off in the single-evaporator working on the water alone. When the water heat source temperature decreases, evaporation temperature drop is sharper in the single-evaporator working on the water than in the parallel operation, which suggests the transfer from the parallel operation to the single-evaporator working on the air. In the single-evaporator operation on the water heat source, the evaporation temperature linearly decreases with an increase in superheating. 1 ref., 10 figs.

  18. Heat Pump Water Heater Ducting Strategies with Encapsulated Attics in Climate Zones 2 and 4

    Energy Technology Data Exchange (ETDEWEB)

    Sweet, M. L. [Southface Energy Inst., Upper Marlboro, MD (United States); Francisco, A.; Roberts, S. G.

    2016-05-01

    The focus of this study is on the performance of HPWHs with several different duct configurations and their effects on whole building heating, cooling, and moisture loads. A.O. Smith 60 gallon Voltex (PHPT-60) heat pump water heaters (HPWHs) were included at two project sites and ducted to or located within spray foamed encapsulated attics. The effect of ducting a HPWH's air stream does not diminish its efficiency if the ducting does not reduce intake air temperature, which expands HPWH application to confined areas. Exhaust ducts should be insulated to avoid condensation on the exterior, however this imposes a risk of condensation occurring in the duct's interior near the HPWH due to large variation of temperatures between the compressor and the duct and the presence of bulk moisture around the condenser. The HPWH's air conditioning impact on HVAC equipment loads is minimal when the intake and exhaust air streams are connected to a sealed attic and not the living space. A HPWH is not suitable as a replacement dehumidifier in sealed attics as peak moisture loads were observed to only be reduced if the heat pump operated during the morning. It appears that the intake air temperature and humidity was the most dominant variable affecting HPWH performance. Different ducting strategies such as exhaust duct only, intake duct only, and exhaust and intake ducting did not have any effect on HPWH performance.

  19. Gas Engine-Driven Heat Pump Chiller for Air-Conditioning and Hot Water Supply Systems

    Science.gov (United States)

    Fujita, Toshihiko; Mita, Nobuhiro; Moriyama, Tadashi; Hoshino, Norimasa; Kimura, Yoshihisa

    In Part 1 of this study, the performance characteristics of a 457kW gas engine-driven heat pump (GHP) chiller have been obtained from a simulation model analysis for both cooling and heating modes and it has been found that the part-load characteristics of the GHP chiller are fairly well. On the back of Part 1, a computer simulation program has been developed for the evaluation of GHP chiller systems to compare with the other types of heat source systems for air-conditioning and hot water supply applications. The simulation program can be used to estimate annual energy consumption, annual CO2 emission, etc. of the systems with the data of monthly and hourly thermal loads on various buildings, outdoor air conditions, and characteristics of various components comprising the systems. By applying this to some cases of medium-scale hotel, office, shop, and hospital buildings, it has been found that the GHP chiller systems have advantages particularly in the cases of hotels and hospitals where a lot of hot water demand exists. It has also been found that the combination of a GHP chiller and a direct-fired absorption water chiller boiler (hot and chilled water generator) appears promising.

  20. Ground Source Heat Pump in Heating System with Electronics Monitoring

    Directory of Open Access Journals (Sweden)

    NEAMŢU Ovidiu

    2013-10-01

    Full Text Available The monitoring system is implemented for a ground coupled heat pump in heating/ system. The borehole heat exchangers – which are 150 m long - are filled with a mixture of water and ethilene glycol calledbrine. Metering and monitoring energy consumption is achieved for: heat pump, circulation pumps, additional electrical heating, hot air ventilation systems, control systems with sensors: analog and smart sensors. Instantaneous values are stored in a local computer.

  1. Geothermal Heat Pump Performance

    Energy Technology Data Exchange (ETDEWEB)

    Boyd, Tonya L.; Lienau, Paul J.

    1995-01-01

    Geothermal heat pump systems are a promising new energy technology that has shown rapid increase in usage over the past ten years in the United States. These systems offer substantial benefits to customers and utilities in energy (kWh) and demand (kW) savings. The purpose of this study was to determine what existing monitored data was available mainly from electric utilities on heat pump performance, energy savings and demand reduction for residential, school, and commercial building applications. Information was developed on the status of electric utility marketing programs, barriers to market penetration, incentive programs, and benefits.

  2. Geothermal heat pump performance

    Energy Technology Data Exchange (ETDEWEB)

    Boyd, Tonya L.; Lienau, Paul J.

    1995-01-01

    Geothermal heat pump systems are a promising new energy technology that has shown rapid increase in usage over the past ten years in the United States. These systems offer substantial benefits to customers and utilities in energy (kWh) and demand (kW) savings. The purpose of this study was to determine what existing monitored data was available mainly from electric utilities on heat pump performance, energy savings and demand reduction for residential, school, and commercial building applications. Information was developed on the status of electric utility marketing programs, barriers to market penetration, incentive programs, and benefits.

  3. Analysis of a Hybrid PV/Thermal Solar-Assisted Heat Pump System for Sports Center Water Heating Application

    Directory of Open Access Journals (Sweden)

    Y. Bai

    2012-01-01

    Full Text Available The application of solar energy provides an alternative way to replace the primary source of energy, especially for large-scale installations. Heat pump technology is also an effective means to reduce the consumption of fossil fuels. This paper presents a practical case study of combined hybrid PV/T solar assisted heat pump (SAHP system for sports center hot water production. The initial design procedure was first presented. The entire system was then modeled with the TRNSYS 16 computation environment and the energy performance was evaluated based on year round simulation results. The results show that the system COP can reach 4.1 under the subtropical climate of Hong Kong, and as compared to the conventional heating system, a high fractional factor of energy saving at 67% can be obtained. The energy performances of the same system under different climatic conditions, that include three other cities in France, were analyzed and compared. Economic implications were also considered in this study.

  4. Heat Pump Water Heater Technology Assessment Based on Laboratory Research and Energy Simulation Models: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Hudon, K.; Sparn, B.; Christensen, D.; Maguire, J.

    2012-02-01

    This paper explores the laboratory performance of five integrated Heat Pump Water Heaters (HPWHs) across a wide range of operating conditions representative of US climate regions. Laboratory results demonstrate the efficiency of this technology under most of the conditions tested and show that differences in control schemes and design features impact the performance of the individual units. These results were used to understand current model limitations, and then to bracket the energy savings potential for HPWH technology in various US climate regions. Simulation results show that HPWHs are expected to provide significant energy savings in many climate zones when compared to other types of water heaters (up to 64%, including impact on HVAC systems).

  5. Pioneering Heat Pump Project

    Energy Technology Data Exchange (ETDEWEB)

    Aschliman, Dave [Indiana Inst. of Technology, Inc., Fort Wayne, IN (United States); Lubbehusen, Mike [Indiana Inst. of Technology, Inc., Fort Wayne, IN (United States)

    2015-06-30

    This project was initiated at a time when ground coupled heat pump systems in this region were limited in size and quantity. There were economic pressures with costs for natural gas and electric utilities that had many organizations considering ground coupled heat pumps; The research has added to the understanding of how ground temperatures fluctuate seasonally and how this affects the performance and operation of the heat pumps. This was done by using a series of temperature sensors buried within the middle of one of the vertical bore fields with sensors located at various depths below grade. Trending of the data showed that there is a lag in ground temperature with respect to air temperatures in the shoulder months, however as full cooling and heating season arrives, the heat rejection and heat extraction from the ground has a significant effect on the ground temps; Additionally it is better understood that while a large community geothermal bore field serving multiple buildings does provide a convenient central plant to use, it introduces complexity of not being able to easily model and predict how each building will contribute to the loads in real time. Additional controllers and programming were added to provide more insight into this real time load profile and allow for intelligent shedding of load via a dry cooler during cool nights in lieu of rejecting to the ground loop. This serves as a means to ‘condition’ the ground loop and mitigate thermal creep of the field, as is typically observed; and It has been observed when compared to traditional heating and cooling equipment, there is still a cost premium to use ground source heat pumps that is driven mostly by the cost for vertical bore holes. Horizontal loop systems are less costly to install, but do not perform as well in this climate zone for heating mode

  6. Heat driven pulse pump

    Science.gov (United States)

    Benner, Steve M (Inventor); Martins, Mario S. (Inventor)

    2000-01-01

    A heat driven pulse pump includes a chamber having an inlet port, an outlet port, two check valves, a wick, and a heater. The chamber may include a plurality of grooves inside wall of the chamber. When heated within the chamber, a liquid to be pumped vaporizes and creates pressure head that expels the liquid through the outlet port. As liquid separating means, the wick, disposed within the chamber, is to allow, when saturated with the liquid, the passage of only liquid being forced by the pressure head in the chamber, preventing the vapor from exiting from the chamber through the outlet port. A plurality of grooves along the inside surface wall of the chamber can sustain the liquid, which is amount enough to produce vapor for the pressure head in the chamber. With only two simple moving parts, two check valves, the heat driven pulse pump can effectively function over the long lifetimes without maintenance or replacement. For continuous flow of the liquid to be pumped a plurality of pumps may be connected in parallel.

  7. Building America Case Study: Multifamily Central Heat Pump Water Heaters, Davis, California

    Energy Technology Data Exchange (ETDEWEB)

    2017-03-08

    Although heat pump water heaters (HPWHs) have gained significant attention in recent years as a high efficiency electric water heating solution for single family homes, central HPWHs for commercial or multi-family applications are not as well documented in terms of measured performance and cost effectiveness. To evaluate this technology, the Alliance for Residential Building Innovation team monitored the performance of a 10.5 ton central HPWH installed on a student apartment building at the West Village Zero Net Energy Community in Davis, California. Monitoring data collected over a 16-month period were then used to validate a TRNSYS simulation model. The TRNSYS model was then used to project performance in different climates using local electric rates. Results of the study indicate that after some initial commissioning issues, the HPWH operated reliably with an annual average efficiency of 2.12 (Coefficient of Performance). The observed efficiency was lower than the unit's rated efficiency, primarily due to the fact that the system rarely operated under steady-state conditions. Changes in the system configuration, storage tank sizing, and control settings would likely improve the observed field efficiency. Modeling results suggest significant energy savings relative to electric storage water heating systems (typical annual efficiencies around 0.90) providing for typical simple paybacks of six to ten years without any incentives. The economics versus gas water heating are currently much more challenging given the current low natural gas prices in much of the country. Increased market size for this technology would benefit cost effectiveness and spur greater technology innovation.

  8. Building America Case Study: Multifamily Central Heat Pump Water Heaters, Davis, California

    Energy Technology Data Exchange (ETDEWEB)

    M. Hoeschele, E. Weitzel

    2017-03-01

    Although heat pump water heaters (HPWHs) have gained significant attention in recent years as a high efficiency electric water heating solution for single family homes, central HPWHs for commercial or multi-family applications are not as well documented in terms of measured performance and cost effectiveness. To evaluate this technology, the Alliance for Residential Building Innovation team monitored the performance of a 10.5 ton central HPWH installed on a student apartment building at the West Village Zero Net Energy Community in Davis, California. Monitoring data collected over a 16-month period were then used to validate a TRNSYS simulation model. The TRNSYS model was then used to project performance in different climates using local electric rates. Results of the study indicate that after some initial commissioning issues, the HPWH operated reliably with an annual average efficiency of 2.12 (Coefficient of Performance). The observed efficiency was lower than the unit's rated efficiency, primarily due to the fact that the system rarely operated under steady-state conditions. Changes in the system configuration, storage tank sizing, and control settings would likely improve the observed field efficiency. Modeling results suggest significant energy savings relative to electric storage water heating systems (typical annual efficiencies around 0.90) providing for typical simple paybacks of six to ten years without any incentives. The economics versus gas water heating are currently much more challenging given the current low natural gas prices in much of the country. Increased market size for this technology would benefit cost effectiveness and spur greater technology innovation.

  9. Reliable, Economic, Efficient CO2 Heat Pump Water Heater for North America

    Energy Technology Data Exchange (ETDEWEB)

    Radcliff, Thomas D; Sienel, Tobias; Huff, Hans-Joachim; Thompson, Adrian; Sadegh, Payman; Olsommer, Benoit; Park, Young

    2006-12-31

    Adoption of heat pump water heating technology for commercial hot water could save up to 0.4 quads of energy and 5 million metric tons of CO2 production annually in North America, but industry perception is that this technology does not offer adequate performance or reliability and comes at too high of a cost. Development and demonstration of a CO2 heat pump water heater is proposed to reduce these barriers to adoption. Three major themes are addressed: market analysis to understand barriers to adoption, use of advanced reliability models to design optimum qualification test plans, and field testing of two phases of water heater prototypes. Market experts claim that beyond good performance, market adoption requires 'drop and forget' system reliability and a six month payback of first costs. Performance, reliability and cost targets are determined and reliability models are developed to evaluate the minimum testing required to meet reliability targets. Three phase 1 prototypes are designed and installed in the field. Based on results from these trials a product specification is developed and a second phase of five field trial units are built and installed. These eight units accumulate 11 unit-years of service including 15,650 hours and 25,242 cycles of compressor operation. Performance targets can be met. An availability of 60% is achieved and the capability to achieve >90% is demonstrated, but overall reliability is below target, with an average of 3.6 failures/unit-year on the phase 2 demonstration. Most reliability issues are shown to be common to new HVAC products, giving high confidence in mature product reliability, but the need for further work to minimize leaks and ensure reliability of the electronic expansion valve is clear. First cost is projected to be above target, leading to an expectation of 8-24 month payback when substituted for an electric water heater. Despite not meeting all targets, arguments are made that an industry leader could

  10. Regional Variation in Residential Heat Pump Water Heater Performance in the U.S.: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Maguire, J.; Burch, J.; Merrigan, T.; Ong, S.

    2014-01-01

    Residential heat pump water heaters (HPWHs) have recently reemerged on the U.S. market. These units have the potential to provide homeowners significant cost and energy savings. However, actual in use performance of a HPWH will vary significantly with climate, installation location, HVAC equipment, and hot water use. To determine what actual in use energy consumption of a HPWH may be in different regions of the U.S., annual simulations of both 50 and 80 gallon HPWHs as well as a standard electric water heater were performed for over 900 locations across the U.S. The simulations included a benchmark home to take into account interactions between the space conditioning equipment and the HPWH and a realistic hot water draw profile. It was found that the HPWH will always save some source energy when compared to a standard electric resistance water heater, although savings varies widely with location. In addition to looking at source energy savings, the breakeven cost (the net installed cost a HPWH would have to have to be a cost neutral replacement for a standard water heater) was also examined. The highest breakeven costs were seen in cases with high energy savings, such as the southeastern U.S., or high energy costs, such as New England and California. While the breakeven cost is higher for 80 gallon units than 50 gallon units, the higher net installed costs of an 80 gallon unit lead to the 50 gallon HPWHs being more likely to be cost effective.

  11. Regional Variation in Residential Heat Pump Water Heater Performance in the U.S.

    Energy Technology Data Exchange (ETDEWEB)

    Maguire, Jeff [National Renewable Energy Lab. (NREL), Golden, CO (United States); Burch, Jay [National Renewable Energy Lab. (NREL), Golden, CO (United States); Merrigan, Tim [National Renewable Energy Lab. (NREL), Golden, CO (United States); Ong, Sean [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2014-01-01

    Residential heat pump water heaters (HPWHs) have recently re-emerged on the U.S. market, and they have the potential to provide homeowners significant cost and energy savings. However, actual in use performance of a HPWH will vary significantly with climate, installation location, HVAC equipment, and hot water use. To determine the actual energy consumption of a HPWH in different U.S. regions, annual simulations of both 50 and 80 gallon HPWHs as well as a standard electric water heater were performed for over 900 locations across the United States. The simulations included a benchmark home to take into account interactions between the space conditioning equipment and the HPWH and a realistic hot water draw profile. It was found that the HPWH will always save some source energy when compared to a standard electric resistance water heater, although savings varies widely with location. In addition to looking at source energy savings, the breakeven cost (the net installed cost a HPWH would have to have to be a cost neutral replacement for a standard water heater) was also examined. The highest breakeven costs were seen in cases with high energy savings, such as the southeastern U.S., or high energy costs, such as New England and California. While the breakeven cost is higher for 80 gallon units than 50 gallon units, the higher net installed costs of an 80 gallon unit lead to the 50 gallon HPWHs being more likely to be cost effective.

  12. Experimental evaluation of a heat pump for the water-supply heating of a public swimming pool

    Science.gov (United States)

    López, R.; Vaca, M.; Terres, H.; Lizardi, A.; Morales, J.; Chávez, S.

    2017-01-01

    In this work the analysis of the thermodynamic behavior of heat pumps (HP) which supply the energy needed in the public pool at the Aquatic Center of Azcapotzalco was performed. There are 18 installed HP’s but only those needed to provide the energy required are alternately activated. The evaluation was conducted during May and June of 2015. We selected one of the HP to implement temperature and pressure gauges at the inlet and outlet of the compressor. The measurements were made every day at three times, 6:30, 13:00 and 18:00 hours. In a period of 24 hours, 1 000 L evaporated, there was no variation registered overnight, since the pool was covered with plastic to avoid loss of the fluid. The heat pump provided 150 kW to maintain the water temperature at the right level of operation, namely 28 °C. The coefficients of performance (COP) of the HP were 6.39 at 6:30, 7.42 at 13:00 and 7:32 at 18:00 hrs., values which are very close to the one provided by the manufacturer.

  13. Technology assessment heat pumps

    Energy Technology Data Exchange (ETDEWEB)

    Rudolph, R.; Purper, G. (Battelle-Institut e.V., Frankfurt am Main (Germany, F.R.))

    Technology assessment for an increased application of heat pumps is carried out in four areas: Effects in the economics area, i.e. effects on the economic goals which are defined in the Stability Law, on the goals of the power supply policy which result from the energy programme and its projections, and on the economic structure as a whole. The whole range of social problems concerning the use of heat pumps, i.e. the questions which social groups are affected, how they react, and what consequences are they expected to have on energy conservation as an object of social policy. Consequences in the governmental and administrative sectors, i.e. effects on legislation, administration and government budgets. Effects on the ecological systems; of prime interest in this context are the utilisation of environmental energy, changes in the heat balance, and emmission of pollutants.

  14. RSES heat pump technician certification

    Energy Technology Data Exchange (ETDEWEB)

    Zeiner, J.

    1996-06-01

    In 1987 the National Heat Pump certification test was developed by the Refrigeration Service Engineers Society (RSES), and in 1994, the program was more specifically named Heat Pump Service Technician Certification. This report describes the benefits of certification.

  15. Industrial Heat Pump for a High Temperature District Heating Application

    DEFF Research Database (Denmark)

    Poulsen, Claus Nørgaard

    2013-01-01

    by excess thermal energy from thermal solar panels. An industrial heat pump system using the natural refrigerant ammonia, is extracting the thermal energy from the storage when needed, and produce hot water at 85°C, for the district heating grid. The heat pump also acts as contributor to electricity grid...

  16. Air-to-Water Heat Pumps With Radiant Delivery in Low-Load Homes

    Energy Technology Data Exchange (ETDEWEB)

    Backman, C.; German, A.; Dakin, B.; Springer, D.

    2013-12-01

    Space conditioning represents nearly 50% of average residential household energy consumption, highlighting the need to identify alternative cost-effective, energy-efficient cooling and heating strategies. As homes are better built, there is an increasing need for strategies that are particularly well suited for high performance, low load homes. ARBI researchers worked with two test homes in hot-dry climates to evaluate the in-situ performance of air-to-water heat pump (AWHP) systems, an energy efficient space conditioning solution designed to cost-effectively provide comfort in homes with efficient, safe, and durable operation. Two monitoring projects of test houses in hot-dry climates were initiated in 2010 to test this system. Both systems were fully instrumented and have been monitored over one year to capture complete performance data over the cooling and heating seasons. Results are used to quantify energy savings, cost-effectiveness, and system performance using different operating modes and strategies. A calibrated TRNSYS model was developed and used to evaluate performance in various climate regions. This strategy is most effective in tight, insulated homes with high levels of thermal mass (i.e. exposed slab floors).

  17. Air-to-Water Heat Pumps With Radiant Delivery in Low-Load Homes

    Energy Technology Data Exchange (ETDEWEB)

    Backman, C. [Alliance for Residential Building Innovation (ARBI), Davis, CA (United States); German, A. [Alliance for Residential Building Innovation (ARBI), Davis, CA (United States); Dakin, B. [Alliance for Residential Building Innovation (ARBI), Davis, CA (United States); Springer, D. [Alliance for Residential Building Innovation (ARBI), Davis, CA (United States)

    2013-12-01

    Space conditioning represents nearly 50% of average residential household energy consumption, highlighting the need to identify alternative cost-effective, energy-efficient cooling and heating strategies. As homes are better built, there is an increasing need for strategies that are particularly well suited for high performance, low load homes. ARBI researchers worked with two test homes in hot-dry climates to evaluate the in-situ performance of air-to-water heat pump systems, an energy efficient space conditioning solution designed to cost-effectively provide comfort in homes with efficient, safe, and durable operation. Two monitoring projects of test houses in hot-dry climates were initiated in 2010 to test this system. Both systems were fully instrumented and have been monitored over one year to capture complete performance data over the cooling and heating seasons. Results are used to quantify energy savings, cost-effectiveness, and system performance using different operating modes and strategies. A calibrated TRNSYS model was developed and used to evaluate performance in various climate regions. This strategy is most effective in tight, insulated homes with high levels of thermal mass (i.e. exposed slab floors).

  18. Commercial Integrated Heat Pump with Thermal Storage --Demonstrate Greater than 50% Average Annual Energy Savings, Compared with Baseline Heat Pump and Water Heater (Go/No-Go) FY16 4th Quarter Milestone Report

    Energy Technology Data Exchange (ETDEWEB)

    Shen, Bo [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Baxter, Van D. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Rice, C. Keith [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Abu-Heiba, Ahmad [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2017-03-01

    For this study, we authored a new air source integrated heat pump (AS-IHP) model in EnergyPlus, and conducted building energy simulations to demonstrate greater than 50% average energy savings, in comparison to a baseline heat pump with electric water heater, over 10 US cities, based on the EnergyPlus quick-service restaurant template building. We also assessed water heating energy saving potentials using ASIHP versus gas heating, and pointed out climate zones where AS-IHPs are promising.

  19. Air/water heat pumps in older buildings. Energy conservation in a stock; Luft/Wasser-Waermepumpen im Altbau. Energiesparen im Bestand

    Energy Technology Data Exchange (ETDEWEB)

    Bauknecht, Steffen [Mitsubishi Electric, Ratingen (Germany)

    2010-02-15

    Due to the technical development, nowadays it is possible to heat older buildings which are not insulated thermally subsequently with monovalent air/water heat pumps. For example, in Bonn-Oberkassel (Federal Republic of Germany) a nearly one hundred year old art nouveau mansion is supplied with apartment warmth and warm water by means of two air/water heat pumps. The economical heat supply as well as the small structural expenditure decided to use this technology.

  20. West Village Community: Quality Management Processes and Preliminary Heat Pump Water Heater Performance

    Energy Technology Data Exchange (ETDEWEB)

    Dakin, B.; Backman, C.; Hoeschele, M.; German, A.

    2012-11-01

    West Village, a multi-use project underway at the University of California Davis, represents a ground-breaking sustainable community incorporating energy efficiency measures and on-site renewable generation to achieve community-level Zero Net Energy (ZNE) goals. The project when complete will provide housing for students, faculty, and staff with a vision to minimize the community's impact on energy use by reducing building energy use, providing on-site generation, and encouraging alternative forms of transportation. This focus of this research is on the 192 student apartments that were completed in 2011 under Phase I of the West Village multi-year project. The numerous aggressive energy efficiency measures implemented result in estimated source energy savings of 37% over the B10 Benchmark. There are two primary objectives of this research. The first is to evaluate performance and efficiency of the central heat pump water heaters as a strategy to provide efficient electric water heating for net-zero all-electric buildings and where natural gas is not available on site. In addition, effectiveness of the quality assurance and quality control processes implemented to ensure proper system commissioning and to meet program participation requirements is evaluated. Recommendations for improvements that could improve successful implementation for large-scale, high performance communities are identified.

  1. West Village Community. Quality Management Processes and Preliminary Heat Pump Water Heater Performance

    Energy Technology Data Exchange (ETDEWEB)

    Dakin, B. [Alliance for Residential Building Innovation (ARBI), Davis, CA (United States); Backman, C. [Alliance for Residential Building Innovation (ARBI), Davis, CA (United States); Hoeschele, M. [Alliance for Residential Building Innovation (ARBI), Davis, CA (United States); German, A. [Alliance for Residential Building Innovation (ARBI), Davis, CA (United States)

    2012-11-01

    West Village, a multi-use project underway at the University of California Davis, represents a ground-breaking sustainable community incorporating energy efficiency measures and on-site renewable generation to achieve community-level Zero Net Energy (ZNE) goals. When complete, the project will provide housing for students, faculty, and staff with a vision to minimize the community’s impact on energy use by reducing building energy use, providing on-site generation, and encouraging alternative forms of transportation. This focus of this research is on the 192 student apartments that were completed in 2011 under Phase I of the West Village multi-year project. The numerous aggressive energy efficiency measures implemented result in estimated source energy savings of 37% over the B10 Benchmark. There are two primary objectives of this research. The first is to evaluate performance and efficiency of the central heat pump water heaters as a strategy to provide efficient electric water heating for net-zero all-electric buildings and where natural gas is not available on site. In addition, effectiveness of the quality assurance and quality control processes implemented to ensure proper system commissioning and to meet program participation requirements is evaluated. Recommendations for improvements that could improve successful implementation for large-scale, high performance communities are identified.

  2. Building America Case Study: Indoor Heat Pump Water Heaters During Summer in a Hot-Dry Climate, Redding, California

    Energy Technology Data Exchange (ETDEWEB)

    2017-06-15

    Heat pump water heaters offer a significant opportunity to improve water heating performance for the over 40% of U.S. households that heat domestic hot water using electric resistance storage water heaters. Numerous field studies have also been completed documenting performance in a variety of climates and applications. More recent evaluation efforts have focused attention on the performance of May through September 2014, with ongoing winter monitoring being sponsored by California utility partners. Summer results show favorable system performance with extrapolated annual water heating savings of 1,466 to 2,300 kWh per year, based on the observed hot water loads. Additional summer space cooling benefits savings of 121 to 135 kWh per year were projected, further increasing the water heating savings by 5-9%. Given the project schedule for 2014 completion, no heating season impacts were able to be monitored. May through September 2014, with ongoing winter monitoring being sponsored by California utility partners. Summer results show favorable system performance with extrapolated annual water heating savings of 1,466 to 2,300 kWh per year, based on the observed hot water loads. Additional summer space cooling benefits savings of 121 to 135 kWh per year were projected, further increasing the water heating savings by 5-9%. Given the project schedule for 2014 completion, no heating season impacts were able to be monitored.

  3. Impact of Ducting on Heat Pump Water Heater Space Conditioning Energy Use and Comfort

    Energy Technology Data Exchange (ETDEWEB)

    Widder, Sarah H.; Petersen, Joseph M.; Parker, Graham B.; Baechler, Michael C.

    2014-07-21

    Increasing penetration of heat pump water heaters (HPWHs) in the residential sector will offer an important opportunity for energy savings, with a theoretical energy savings of up to 63% per water heater and up to 11% of residential energy use (EIA 2009). However, significant barriers must be overcome before this technology will reach widespread adoption in the Pacific Northwest region and nationwide. One significant barrier noted by the Northwest Energy Efficiency Alliance (NEEA) is the possible interaction with the homes’ space conditioning system for units installed in conditioned spaces. Such complex interactions may decrease the magnitude of whole-house savings available from HPWH installed in the conditioned space in cold climates and could lead to comfort concerns (Larson et al. 2011; Kresta 2012). Modeling studies indicate that the installation location of HPWHs can significantly impact their performance and the resultant whole-house energy savings (Larson et al. 2012; Maguire et al. 2013). However, field data are not currently available to validate these results. This field evaluation of two GE GeoSpring HPWHs in the PNNL Lab Homes is designed to measure the performance and impact on the Lab Home HVAC system of a GE GeoSpring HPWH configured with exhaust ducting compared to an unducted GeoSpring HPWH during heating and cooling season periods; and measure the performance and impact on the Lab Home HVAC system of the GeoSpring HPWH with both supply and exhaust air ducting as compared to an unducted GeoSpring HPWH during heating and cooling season periods. Important metrics evaluated in these experiments include water heater energy use, HVAC energy use, whole house energy use, interior temperatures (as a proxy for thermal comfort), and cost impacts. This technical report presents results from the PNNL Lab Homes experiment.

  4. The use of water as a high temperature heat pump fluid at the Auchroisk distillery, Scotland

    Energy Technology Data Exchange (ETDEWEB)

    Castle, T. [EA Technology Ltd., Chester (United Kingdom)

    1995-12-01

    The first steam heat pump for distillation in the UK was installed in a malt whisky distillery in 1987. Novel aspects of the system are modifications to the batch process to enable continuous and efficient operation of the heat pump across a number of stills, the use of steam in a closed cycle and compression of the steam by a twin-screw compressor. The heat pump is incorporated into the distillery steam distribution system operating in parallel with the existing boiler, allowing complete flexibility of operation. The installation demonstrates the large primary energy savings that can be achieved by the optimisation of integrated heat pumps in batch processes. The principle and much of the system design could be applied to continuous distillation processes and to other batch operations such as drying, steam stripping and solvent recovery. In this paper a steam heat pump is described which has been installed in the Auchroisk malt whisky distillery of International Distillers and Vintners Ltd (IDV). It is a result of a four year R and D programme at EA Technology Ltd. 7 figs., 3 refs.

  5. Heat transfer enhancement and pumping power optimization using CuO-water nanofluid through rectangular corrugated pipe

    Science.gov (United States)

    Salehin, Musfequs; Ehsan, Mohammad Monjurul; Islam, A. K. M. Sadrul

    2017-06-01

    Heat transfer enhancement by corrugation in fluid domain is a popular method. The rate of improvement is more when it is used highly thermal conductive fluid as heating or cooling medium. In this present study, heat transfer augmentation was investigated numerically by implementing corrugation in the fluid domain and nanofluid as the base fluid in the turbulent forced convection regime. Finite volume method (FVM) was applied to solve the continuity, momentum and energy equations. All the numerical simulations were considered for single phase flow. A rectangle corrugated pipe with 5000 W/m2 constant heat flux subjected to the corrugated wall was considered as the fluid domain. In the range of Reynolds number 15000 to 40000, thermo-physical and hydrodynamic behavior was investigated by using CuO-water nanofluid from 1% to 5% volume fraction as the base fluid through the corrugated fluid domain. Corrugation justification was performed by changing the amplitude of the corrugation and the corrugation wave length for obtaining the increased heat transfer rate with minimum pumping power. For using CuO-water nanofluid, augmentation was also found more in the rectangle corrugated pipe both in heat transfer and pumping power requirement with the increase of Reynolds number and the volume fraction of nanofluid. For the increased pumping power, optimization of pumping power by using nanofluid was also performed for economic finding.

  6. Wavy tube heat pumping

    Energy Technology Data Exchange (ETDEWEB)

    Haldeman, C. W.

    1985-12-03

    A PVC conduit about 4'' in diameter and a little more than 40 feet long is adapted for being seated in a hole in the earth and surrounds a coaxial copper tube along its length that carries Freon between a heat pump and a distributor at the bottom. A number of wavy conducting tubes located between the central conducting tube and the wall of the conduit interconnect the distributor with a Freon distributor at the top arranged for connection to the heat pump. The wavy conducting tubing is made by passing straight soft copper tubing between a pair of like opposed meshing gears each having four convex points in space quadrature separated by four convex recesses with the radius of curvature of each point slightly less than that of each concave recess.

  7. Heat cascading regenerative sorption heat pump

    Science.gov (United States)

    Jones, Jack A. (Inventor)

    1995-01-01

    A simple heat cascading regenerative sorption heat pump process with rejected or waste heat from a higher temperature chemisorption circuit (HTCC) powering a lower temperature physisorption circuit (LTPC) which provides a 30% total improvement over simple regenerative physisorption compression heat pumps when ammonia is both the chemisorbate and physisorbate, and a total improvement of 50% or more for LTPC having two pressure stages. The HTCC contains ammonia and a chemisorbent therefor contained in a plurality of canisters, a condenser-evaporator-radiator system, and a heater, operatively connected together. The LTPC contains ammonia and a physisorbent therefor contained in a plurality of compressors, a condenser-evaporator-radiator system, operatively connected together. A closed heat transfer circuit (CHTC) is provided which contains a flowing heat transfer liquid (FHTL) in thermal communication with each canister and each compressor for cascading heat from the HTCC to the LTPC. Heat is regenerated within the LTPC by transferring heat from one compressor to another. In one embodiment the regeneration is performed by another CHTC containing another FHTL in thermal communication with each compressor. In another embodiment the HTCC powers a lower temperature ammonia water absorption circuit (LTAWAC) which contains a generator-absorber system containing the absorbent, and a condenser-evaporator-radiator system, operatively connected together. The absorbent is water or an absorbent aqueous solution. A CHTC is provided which contains a FHTL in thermal communication with the generator for cascading heat from the HTCC to the LTAWAC. Heat is regenerated within the LTAWAC by transferring heat from the generator to the absorber. The chemical composition of the chemisorbent is different than the chemical composition of the physisorbent, and the absorbent. The chemical composition of the FHTL is different than the chemisorbent, the physisorbent, the absorbent, and ammonia.

  8. Stirling Engine Heat Pump

    Science.gov (United States)

    Kagawa, Noboru

    Recent advances in the feasibility studies related to the Stirling engines and Stirling engine heat pumps which have been considered attractive due to their promising role in helping to solve the global environmental and energy problems,are reviewed. This article begins to describe the brief history of the Stirling engines and theoretical thermodynamic analysis of the Stirling cycle in order to understand several advantages on the Stirling engine. Furthermore,they could throw light on our question why the dream engines had not been promoted to practical applications during two hundred years. The present review shows that the Stirling engines with several unique advantages including 30 to 40% thermal efficiency and preferable exhaust characteristics,had been designed and constructed by recent tackling for the development of the advanced automobile and other applications using them. Based on the current state of art,it is being provided to push the Stirling engines combined with heat pumps based on the reversed Rankine cycle to the market. At present,however, many problems, especially for the durability, cost, and delicate engine parts must be enforced to solve. In addition,there are some possibilities which can increase the attractiveness of the Stirling engines and heat pumps. The review closes with suggestions for further research.

  9. Ground-water temperature of the Wyoming quadrangle in central Delaware : with application to ground-water-source heat pumps

    Science.gov (United States)

    Hodges, Arthur L.

    1982-01-01

    Ground-water temperature was measured during a one-year period (1980-81) in 20 wells in the Wyoming Quadrangle in central Delaware. Data from thermistors set at fixed depths in two wells were collected twice each week, and vertical temperature profiles of the remaining 18 wells were made monthly. Ground-water temperature at 8 feet below land surface in well Jc55-1 ranged from 45.0 degrees F in February to 70.1 degrees F in September. Temperature at 35 feet below land surface in the same well reached a minimum of 56.0 degrees F in August, and a maximum of 57.8 degrees F in February. Average annual temperature of ground water at 25 feet below land surface in all wells ranged from 54.6 degrees F to 57.8 degrees F. Variations of average temperature probably reflect the presence or absence of forestation in the recharge areas of the wells. Ground-water-source heat pumps supplied with water from wells 30 or more feet below land surface will operate more efficiently in both heating and cooling modes than those supplied with water from shallower depths. (USGS)

  10. Research and development of a heat-pump water heater. Volume 2. R and D task reports

    Energy Technology Data Exchange (ETDEWEB)

    Dunning, R.L.; Amthor, F.R.; Doyle, E.J.

    1978-08-01

    The heat pump water heater is a device that works much like a window air conditioner except that heat from the home is pumped into a water tank rather than to the outdoors. The objective established for the device is to operate with a Coefficient of Performance (COP) of 3 or, an input of one unit of electric energy would create three units of heat energy in the form of hot water. With such a COP, the device would use only one-third the energy and at one-third the cost of a standard resistance water heater. This Volume 2 contains the final reports of the three major tasks performed in Phase I. In Task 2, a market study identifies the future market and selects an initial target market and channel of distribution, all based on an analysis of the parameters affecting feasibility of the device and the factors that will affect its market acceptance. In the Task 3 report, the results of a design and test program to arrive at final designs of heat pumps for both new water heaters and for retrofitting existing water heaters are presented. In the Task 4 report, a plan for an extensive field demonstration involving use in actual homes is presented. Volume 1 contains a final summary report of the information in Volume 2.

  11. ENERGY AND ENVIRONMENTAL ANALYSIS OF AN OPEN-LOOP GROUND-WATER HEAT PUMP SYSTEM IN AN URBAN AREA

    Directory of Open Access Journals (Sweden)

    Giorgia Baccino

    2010-01-01

    Full Text Available In this paper a multidisciplinary methodology for analyzing the opportunities for exploitation of open-loop groundwater heat pump is proposed. The approach starts from a model for calculation of a time profile of thermal requirements (heat and domestic hot water. This curve is then coupled with a model of the control system in order to determine the heat pump operation, which includes its energy performances (primary energy consumption as well as profiles of water discharge to the aquifer in terms of mass flow rate and temperature. Then the thermo-fluid dynamics of the aquifer is performed in order to determine the system impact on the environment as on possible other systems. The application to a case study in the Piedmont region, in Italy, is proposed. Energy analysis of the system shows that ground-water heat pumps constitute an interesting option in areas with small housing density, where there is not district heating. In comparison with typical heating/cooling systems, environmental benefits are related with reduction in global emissions. These benefits may be significantly enhanced using renewables as the primary energy source to produce electricity. The analysis also shows that possible issues related with the extension of the subsurface thermal plume may arise in the case of massive utilization of this technology.

  12. Thermal Interface Evaluation of Heat Transfer from a Pumped Loop to Titanium-Water Thermosyphons

    Science.gov (United States)

    Jaworske, Donald A.; Sanzi, James L.; Gibson, Marc A.; Sechkar, Edward A.

    2009-01-01

    Titanium-water thermosyphons are being considered for use in the heat rejection system for lunar outpost fission surface power. Key to their use is heat transfer between a closed loop heat source and the heat pipe evaporators. This work describes laboratory testing of several interfaces that were evaluated for their thermal performance characteristics, in the temperature range of 350 to 400 K, utilizing a water closed loop heat source and multiple thermosyphon evaporator geometries. A gas gap calorimeter was used to measure heat flow at steady state. Thermocouples in the closed loop heat source and on the evaporator were used to measure thermal conductance. The interfaces were in two generic categories, those immersed in the water closed loop heat source and those clamped to the water closed loop heat source with differing thermal conductive agents. In general, immersed evaporators showed better overall performance than their clamped counterparts. Selected clamped evaporator geometries offered promise.

  13. 太阳能-空气复合热源热泵热水系统%Solar-air composite heat source heat pump hot water system

    Institute of Scientific and Technical Information of China (English)

    王岗; 全贞花; 赵耀华; 侯隆澍; 徐俊芳; 邓月超

    2014-01-01

    In the light of low efficiency of photovoltaic power generation and the problems of air source heat pump applied in cold regions, a composite heat exchanger evaporator is developed and a new type of solar-air composite heat source heat pump hot water system is designed in this study, which is comprised of independent solar photovoltaic-thermal collector based on flat plate micro heat pipe and air source heat pump. The performance of heat pump hot water system is evaluated experimentally under different operating conditions, including water temperature of the tank, heating time of hot water, suction and discharge pressure, consumption of compressor power and heat pump coefficient of performance (COP), etc. Experimental results show that at ambient temperature of 5℃, 10℃ and 15℃, with 73 L hot water heated by heat pump and water temperature in the tank ranged from 15℃ to 50℃, the running time of composite heat source operation is shorter than that of separate air heat source operation, decreased by 5.14%, 10.29% and 11.38%, respectively. COPs are increased by 5.99%, 9.28%and 11.96%, respectively.%针对光伏发电效率较低和空气源热泵在寒冷地区应用中存在的问题,研发了一种新型复合蒸发器,将平板微热管阵列太阳能光伏光热(PV/T)集热器与空气源热泵相结合,组成新型太阳能-空气复合热源热泵热水系统。并对该热水系统在不同运行工况下的水箱水温、吸排气压力、压缩机功率和性能等进行了实验研究。实验结果表明,在环境温度分别为5、10和15℃的条件下,热泵加热73 L水,水温从15℃加热到50℃时,双热源运行工况的加热时间比单空气热源运行工况依次缩短了5.14%、10.29%和11.38%,COP依次提高了5.99%、9.28%和11.96%。

  14. Heat pumps for sanitary hot water; Bombas de calor para agua caliente sanitaria

    Energy Technology Data Exchange (ETDEWEB)

    Lopez, I.

    2010-07-01

    Directive 2009/28/EC on the promotion of the use of energy from renewable sources, published last summer is a policy that makes a difference in that for the first time, it envisages the aerothermal renewable energy source. One of the more energies used by heat pumps. (Author)

  15. Maldistribution in air-water heat pump evaporators. Part 2: Economic analysis of counteracting technologies

    DEFF Research Database (Denmark)

    Mader, Gunda; Palm, Björn; Elmegaard, Brian

    2015-01-01

    In this study a methodology is applied to quantify the effect of evaporator maldistributionon operating costs of airewater heat pumps. The approach is used to investigate the cost-effectivenessof two technologies enabling to counteract maldistribution: a flash gasbypass setup and the individual...

  16. Heat Pump Water Heater Technology: Experiences of Residential Consumers and Utilities

    Energy Technology Data Exchange (ETDEWEB)

    Ashdown, BG

    2004-08-04

    This paper presents a case study of the residential heat pump water heater (HPWH) market. Its principal purpose is to evaluate the extent to which the HPWH will penetrate the residential market sector, given current market trends, producer and consumer attributes, and technical parameters. The report's secondary purpose is to gather background information leading to a generic framework for conducting market analyses of technologies. This framework can be used to compare readiness and to factor attributes of market demand back into product design. This study is a rapid prototype analysis rather than a detailed case analysis. For this reason, primary data collection was limited and reliance on secondary sources was extensive. Despite having met its technical goals and having been on the market for twenty years, the HPWH has had virtually no impact on contributing to the nation's water heating. In some cases, HPWH reliability and quality control are well below market expectations, and early units developed a reputation for unreliability, especially when measured against conventional water heaters. In addition to reliability problems, first costs of HPWH units can be three to five times higher than conventional units. Without a solid, well-managed business plan, most consumers will not be drawn to this product. This is unfortunate. Despite its higher first costs, efficiency of an HPWH is double that of a conventional water heater. The HPWH also offers an attractive payback period of two to five years, depending on hot water usage. On a strict life-cycle basis it supplies hot water very cost effectively. Water heating accounts for 17% of the nation's residential consumption of electricity (see chart at left)--water heating is second only to space heating in total residential energy use. Simple arithmetic suggests that this figure could be reduced to the extent HPWH technology displaces conventional water heating. In addition, the HPWH offers other

  17. Energy efficient ammonia heat pump. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Madsen, Claus; Pijnenburg, B.; Schumann Grindorf, H. [Danish Technological Institute, Aarhus (Denmark); Christensen, Rolf [Alfa Laval, Lund (Sweden); Rasmussen, Bjarne D. [Grundfos, Bjerringbro (Denmark); Gram, S.; Fredborg Jakobsen, D. [Svedan Industri Koeleanlaeg, Greve (Denmark)

    2013-09-15

    The report describes the development of a highly effective ammonia heat pump. Heat pumps play an increasingly important role in the search for more effective use of energy in our society. Highly efficient heat pumps can contribute to reduced energy consumption and improved economy of the systems which they are a part of. An ammonia heat pump with high pressure reciprocating compressor and a novel split condenser was developed to prove potential for efficiency optimization. The split of the condenser in two parts can be utilized to obtain smaller temperature approaches and, thereby, improved heat pump efficiency at an equal heat exchanger area, when compared to the traditional solution with separate condenser and de-superheater. The split condenser design can also be exploited for heating a significant share of the total heating capacity to a temperature far above the condensing temperature. Furthermore, the prototype heat pump was equipped with a plate type evaporator combined with a U-turn separator with a minimum liquid height and a liquid pump with the purpose of creating optimum liquid circulation ratio for the highest possible heat transfer coefficients at the lowest possible pressure drop. The test results successfully confirmed the highest possible efficiency; a COP of 4.3 was obtained when heating water from 40 deg. C to 80 deg. C while operating with evaporating/condensing temperatures of +20 deg C/+73 deg C. (Author)

  18. Absorption heat pump for space applications

    Science.gov (United States)

    Nguyen, Tuan; Simon, William E.; Warrier, Gopinath R.; Woramontri, Woranun

    1993-01-01

    In the first part, the performance of the Absorption Heat Pump (AHP) with water-sulfuric acid and water-magnesium chloride as two new refrigerant-absorbent fluid pairs was investigated. A model was proposed for the analysis of the new working pairs in a heat pump system, subject to different temperature lifts. Computer codes were developed to calculate the Coefficient of Performance (COP) of the system with the thermodynamic properties of the working fluids obtained from the literature. The study shows the potential of water-sulfuric acid as a satisfactory replacement for water-lithium bromide in the targeted temperature range. The performance of the AHP using water-magnesium chloride as refrigerant-absorbent pair does not compare well with those obtained using water-lithium bromide. The second part concentrated on the design and testing of a simple ElectroHydrodynamic (EHD) Pump. A theoretical design model based on continuum electromechanics was analyzed to predict the performance characteristics of the EHD pump to circulate the fluid in the absorption heat pump. A numerical method of solving the governing equations was established to predict the velocity profile, pressure - flow rate relationship and efficiency of the pump. The predicted operational characteristics of the EHD pump is comparable to that of turbomachinery hardware; however, the overall efficiency of the electromagnetic pump is much lower. An experimental investigation to verify the numerical results was conducted. The pressure - flow rate performance characteristics and overall efficiency of the pump obtained experimentally agree well with the theoretical model.

  19. High Efficiency Water Heating Technology Development Final Report. Part I, Lab/Field Performance Evaluation and Accelerated Life Testing of a Hybrid Electric Heat Pump Water Heater (HPWH)

    Energy Technology Data Exchange (ETDEWEB)

    Baxter, Van D. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Murphy, Richard W. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Rice, C. Keith [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Linkous, Randall Lee [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2016-04-01

    DOE has supported efforts for many years with the objective of getting a water heater that uses heat pump technology (aka a heat pump water heater or HPWH) successfully on the residential equipment market. The most recent previous effort (1999-2002) produced a product that performed very well in ORNL-led accelerated durability and field tests. The commercial partner for this effort, Enviromaster International (EMI), introduced the product to the market under the trade name Watter$aver in 2002 but ceased production in 2005 due to low sales. A combination of high sales price and lack of any significant infrastructure for service after the sale were the principal reasons for the failure of this effort. What was needed for market success was a commercial partner with the manufacturing and market distribution capability necessary to allow economies of scale to lead to a viable unit price together with a strong customer service infrastructure. General Electric certainly meets these requirements, and knowing of ORNL s expertise in this area, approached ORNL with the proposal to partner in a CRADA to produce a high efficiency electric water heater. A CRADA with GE was initiated early in Fiscal Year, 2008. GE initially named its product the Hybrid Electric Water Heater (HEWH).

  20. Thermodynamic Analysis of the Use a Chemical Heat Pump to Link a Supercritical Water-Cooled Nuclear Reactor and a Thermochemical Water-Splitting Cycle for Hydrogen Production

    Science.gov (United States)

    Granovskii, Mikhail; Dincer, Ibrahim; Rosen, Marc A.; Pioro, Igor

    Increases in the power generation efficiency of nuclear power plants (NPPs) are mainly limited by the permissible temperatures in nuclear reactors and the corresponding temperatures and pressures of the coolants in reactors. Coolant parameters are limited by the corrosion rates of materials and nuclear-reactor safety constraints. The advanced construction materials for the next generation of CANDU reactors, which employ supercritical water (SCW) as a coolant and heat carrier, permit improved “steam” parameters (outlet temperatures up to 625°C and pressures of about 25 MPa). An increase in the temperature of steam allows it to be utilized in thermochemical water splitting cycles to produce hydrogen. These methods are considered by many to be among the most efficient ways to produce hydrogen from water and to have advantages over traditional low-temperature water electrolysis. However, even lower temperature water splitting cycles (Cu-Cl, UT-3, etc.) require an intensive heat supply at temperatures higher than 550-600°C. A sufficient increase in the heat transfer from the nuclear reactor to a thermochemical water splitting cycle, without jeopardizing nuclear reactor safety, might be effectively achieved by application of a heat pump, which increases the temperature of the heat supplied by virtue of a cyclic process driven by mechanical or electrical work. Here, a high-temperature chemical heat pump, which employs the reversible catalytic methane conversion reaction, is proposed. The reaction shift from exothermic to endothermic and back is achieved by a change of the steam concentration in the reaction mixture. This heat pump, coupled with the second steam cycle of a SCW nuclear power generation plant on one side and a thermochemical water splitting cycle on the other, increases the temperature of the “nuclear” heat and, consequently, the intensity of heat transfer into the water splitting cycle. A comparative preliminary thermodynamic analysis is conducted

  1. Heat pumps in industry. Pt. 2: Applications

    Energy Technology Data Exchange (ETDEWEB)

    Lazzarin, R.M. [Padova Univ., Vicenza (Italy). Ist. di Ingegneria Gestionale

    1995-04-01

    A selection of applications of heat pumps in industry is described, reporting plant lay-outs and performances. The selection includes compression heat pumps at different temperatures, vapour recompression systems, absorption heat pumps and heat transformers. (author)

  2. A regenerative elastocaloric heat pump

    Science.gov (United States)

    Tušek, Jaka; Engelbrecht, Kurt; Eriksen, Dan; Dall'Olio, Stefano; Tušek, Janez; Pryds, Nini

    2016-10-01

    A large fraction of global energy use is for refrigeration and air-conditioning, which could be decarbonized if efficient renewable energy technologies could be found. Vapour-compression technology remains the most widely used system to move heat up the temperature scale after more than 100 years; however, caloric-based technologies (those using the magnetocaloric, electrocaloric, barocaloric or elastocaloric effect) have recently shown a significant potential as alternatives to replace this technology due to high efficiency and the use of green solid-state refrigerants. Here, we report a regenerative elastocaloric heat pump that exhibits a temperature span of 15.3 K on the water side with a corresponding specific heating power up to 800 W kg-1 and maximum COP (coefficient-of-performance) values of up to 7. The efficiency and specific heating power of this device exceeds those of other devices based on caloric effects. These results open up the possibility of using the elastocaloric effect in various cooling and heat-pumping applications.

  3. Performance of a Solar Heating System with Photovoltaic Thermal Hybrid Collectors and Heat Pump

    DEFF Research Database (Denmark)

    Dannemand, Mark; Furbo, Simon; Perers, Bengt

    2017-01-01

    . When the solar collectors are unable to supply the heat demand an auxiliary heat source is used. Heat pumps can generate this heat. Liquid/water heat pumps have better performance than air/water heat pumps in cold climates but requires installation of a tubing system for the cold side of the heat pump....... The tubes are typically placed in the ground, requires a significant land area and increase the installation cost. A new system design of a solar heating system with two storage tanks and a liquid/water heat pump is presented. The system consists of PVT collectors that generate both heat and electricity....... Heat from the collectors is transferred to a domestic hot water storage tank or to a cold storage tank, which is used as the source for the heat pump. When the heat pump charges the warm storage tank, heat is extracted from the cold storage tank, which then can be reheated by the PVT collectors...

  4. Heat pumps for the home

    CERN Document Server

    Cantor, John

    2013-01-01

    In recent years, heat pumps have emerged as a promising new form of technology with a relatively low environmental impact. Moreover, they have presented householders with an opportunity to reduce their heating bills. Heat pumps can heat a building by 'pumping' heat from either the ground or the air outside: an intriguing process which utilizes principles that are somewhat analogous to those employed in the domestic refrigerator. Armed with the practical information contained in these pages, homeowners will have the necessary knowledge to take advantage of this potentially low-carbon t

  5. Compact High Efficiency Adsorption Heat Pump

    OpenAIRE

    TeGrotenhuis, Ward E; Humble, Paul H; Sweeney, Josh B

    2012-01-01

    An innovative adsorption cycle heat pump technology is presented that is compact and capable of achieving high energy efficiency for integrated space heating, air conditioning, and water heating. High energy efficiency is accomplished by effectively recuperating heat within the system to minimize energy consumption. This substantially reduces the thermodynamic losses that occur when the sorbent beds are thermally cycled without effective heat recuperation. Furthermore, equipment cost is reduc...

  6. Commercialization of air conditioning heat pump/water heater. Final technical report, Volume 2: Appendix A through E

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-01-30

    This is the final technical report on a commercialization project for an air conditioning heat pump water heater. The objective of the project was to produce a saleable system which would be economically competitive with natural gas and cost effective with regard to initial cost versus annual operating costs. The development and commercialization of the system is described. Compiled data included in numerous figures, tables and graphs.

  7. Peltier heat pumps. Peltiervaermepumpar

    Energy Technology Data Exchange (ETDEWEB)

    Torstensson, H. (Studsvik Energy, Nykoeping (SE))

    1990-06-01

    Todays Peltier devices in heat pump applications gives a low coeffificent of performance. A temperature difference of 40 deg C results in a COP-value of approx. 1.3. Peltier devices are manufactured of alloys composed of heavy elements like tellurium, selenium, bismuth and antimony. These elements thermoelectrical properties, figure of merit are decisive to the performance of the Peltier devices. An upper limit for the figure of merit, ZT, is said to be 2, which at {Delta}T=40 deg C would yield a COP of 2.0 as a maximum. Organic compounds have been investigated with regard to the electric conductivity. Thin film technique have been used for Peltier devices in micro-scale. There are no large-scale applications. The method does not give enhanced termoelectrical properties, but more rational and cheaper manufacturing. (author) (47 refs., 26 figs.).

  8. Heat pumps in district heating networks

    DEFF Research Database (Denmark)

    Ommen, Torben Schmidt; Markussen, Wiebke Brix; Elmegaard, Brian

    constraints limit the power plants. Efficient heat pumps can be used to decouple the constraints of electricity and heat production, while maintaining the high energy efficiency needed to match the politically agreed carbon emission goals. The requirements in terms of COP, location, capacity and economy...... are calculated using an energy system model which includes power plants, heat pumps and district heating consumption profiles. The model is developed with focus on accurate representation of the performance of the units in different locations and operating modes. The model can assist in investment decisions...... and strategic planning in the energy sector. The paper presents a case study of optimal implementation of heat pumps in the present energy system of the Copenhagen area. By introduction of the correct capacity of heat pumps, a 1,6 % reduction in fuel consumption for electricity and heat production can...

  9. Financial viability study using a heat pump as an alternative to support solar collector for water heating in Southeastern Brazil

    Energy Technology Data Exchange (ETDEWEB)

    Reis, Roberts Vinicius de Melo; Oliveira, Raphael Nunes; Machado, Luiz; Koury, Ricardo Nassau N. [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Dept. of Mechanical Engineering], E-mails: robertsreis@ufmg.br, luizm@demec.ufmg.br, koury@ufmg.br

    2010-07-01

    Along with related greenhouse effect environmental issues, constant problems changes in oil prices,make the use of solar energy an important renewable energy source. Brazil is a country which is privilege, considering the high rates of solar irradiation present throughout most of the entire national territory. Nevertheless, during certain times of the year, a solar energy deficit, leads solar systems to require electrical resistance support. The use of electrical resistance represents 23.5% of electric energy consumption and it presents a low residential energy efficiency. The purpose of this work is conducting a study of Brazilian States in the Southeastern region regarding the financial viability of replacing a resistive system combined with the use of solar collector and a heat pump. One such heat pump has been designed, constructed and tested experimentally. The average performance coefficient is equal to 2.10, a low value due to the use of a hermetic reciprocating compressor. Despite this low-moderate price coefficient of acquisition and installation of a heat pump, a return on investment in from 2.1 to 2.7 years can be expected. Whereas the equipment has a useful life of about 20 years, this period of return on investment is interesting. (author)

  10. Multifunctional Heat Pump Installation for Dairy Plants

    Directory of Open Access Journals (Sweden)

    Sit M.L.

    2015-08-01

    Full Text Available The article presents the installation based on the approach using the integration of the carbon dioxide heat pump in pasteurization and cooling installation for milk and in installations for preparing of hot and "icy" water. The scheme differs from the prototype by the use of additional heat exchangers and of their connection to the main elements of the installation. A proposed technique of elements connection in the heat pump installation permits to compensate the effect of temperature of cold water supply source, which is low-grade heat source for the heat pump, on the quality the work of the installation. The design of the installation enables to compensate the impact of seasonal variation of water temperature. The installation ensures the COP = 5.3.

  11. Industrial heat pump assessment study

    Science.gov (United States)

    Chappell, R. N.; Priebe, S. J.; Wilfert, G. L.

    1989-03-01

    This report summarizes preliminary studies that assess the potential of industrial heat pumps for reduction of process heating requirements in industries receiving power from the Bonneville Power Administration (BPA). This project was initiated at the request of BPA to determine the potential of industrial heat pumps in BPA's service area. Working from known heat pump principles and from a list of BPA's industrial customers, the authors estimated the fuel savings potential for six industries. Findings indicate that the pulp and paper industry would yield the greatest fuel savings and increased electrical consumption. Assessments presented in this report represent a cooperative effort between The Idaho National Engineering Laboratory (INEL), and Battelle-Northwest Laboratories.

  12. Magnetic heat pump flow director

    Science.gov (United States)

    Howard, Frank S. (Inventor)

    1995-01-01

    A fluid flow director is disclosed. The director comprises a handle body and combed-teeth extending from one side of the body. The body can be formed of a clear plastic such as acrylic. The director can be used with heat exchangers such as a magnetic heat pump and can minimize the undesired mixing of fluid flows. The types of heat exchangers can encompass both heat pumps and refrigerators. The director can adjust the fluid flow of liquid or gas along desired flow directions. A method of applying the flow director within a magnetic heat pump application is also disclosed where the comb-teeth portions of the director are inserted into the fluid flow paths of the heat pump.

  13. Demand flexibility from residential heat pump

    DEFF Research Database (Denmark)

    Bhattarai, Bishnu Prasad; Bak-Jensen, Birgitte; Pillai, Jayakrishnan Radhakrishna

    2014-01-01

    with high thermal time constant, heat pumps (HP) can offer a great deal of flexibility in the future intelligent grids especially to compensate fluctuating generation. However, the HP flexibility is highly dependent on thermal demand profile, namely hot water and space heating demand. This paper proposes...

  14. Offshore watersource heat pump applications

    Energy Technology Data Exchange (ETDEWEB)

    Clark, W.H. II [ARK Associates, Round Rock, TX (United States)

    1996-10-01

    This paper discusses applications of the Water Source Heat Pump (WSHP) technology for offshore drilling or production operations to result in a substantial savings in space conditioning to result in a substantial savings in space conditioning and domestic hot water production. An even more cost competitive application of the WSHP is the once thorough design which circulates cool water from deep in the ocean straight through the unit, then discharges it to the ocean surface. A modification of this open loop technique circulates the fluid within an abandoned well bore casing. The advantage of this system is that natural convection of warm water from deep in the well upward, as the unit returns cool water at or near the surface, will greatly enhance the thermal advantage of the system. This will enable direct use in the heating season and perhaps be sufficient to operate an absorption chiller in the cooling season. The initial cost of either of these systems is equivalent to a packaged ac system, making the WSHP an ideal energy conservation measure.

  15. Study on the Adaptability of Lake Water-source Heat Pump in the Heating Engineering%湖水源热泵冬季供暖适应性研究

    Institute of Scientific and Technical Information of China (English)

    梁昌祝; 陈静; 邓博

    2014-01-01

    The adaptability of lake water source heat pump in winter for heating is analyzed from aspects of lake water temperature, energy efficiency of heat pump units, environmental impact of cooling water drainage and energy saving of heat pump systems. The research shows that lake water source heat pump has good energy-saving effect when used for heating, with measured energy efficiency of heat pump units reaching 4.34 ~ 4.81. The relative energy-saving rate of water source heat pump system reaches 5%, 68% and 29.8% compared with air source heat pump, electric boiler and gas boiler respectively.%从湖体水温、热泵机组能效、冷排水对水环境的影响及热泵系统节能性四个方面分析了湖水源热泵在冬季供暖的适应性。研究表明,湖水源热泵供暖技术具有良好的节能效益,实测热泵机组能效达到4.34~4.81,相对传统的风冷热泵、电锅炉、燃气锅炉系统而言,水源热泵系统的节能率分别达到5%、68%和29.8%。

  16. Heat pumps at the maltings

    Energy Technology Data Exchange (ETDEWEB)

    1987-11-01

    Heat pumps have halved the energy costs of producing finished malt at two of the country's maltsters. The fuel-fired kilning processes described are now performed by heat pumps with considerable energy and production benefits at the maltings of J.P. Simpson and Co. (Alnwick) Ltd, in Tivetshall St Margaret, Norfolk, and of Munton and Fison Plc of Stowmarket, Suffolk. The heat pump system installed at the Station Malting of J.P. Simpson was devised by the Electricity Council Research Centre at Capenhurst near Chester. Energy cost benefits of Pound 6,000 a month are being realised at Simpsons, but there is the added benefit that the system has been designed to provide conditioned air to the germination cycle to ensure that the correct temperature is maintained throughout the year. At the Cedars factory of Munton and Fison, heat pumps were used on a trial basis for plant micropropagation and for a fish farming unit.

  17. Heat-Powered Pump for Liquid Metals

    Science.gov (United States)

    Campana, R. J.

    1986-01-01

    Proposed thermoelectromagnetic pump for liquid metal powered by waste heat; needs no battery, generator, or other external energy source. Pump turns part of heat in liquid metal into pumping energy. In combination with primary pump or on its own, thermoelectric pump circulates coolant between reactor and radiator. As long as there is decay heat to be removed, unit performs function.

  18. Heat-Powered Pump for Liquid Metals

    Science.gov (United States)

    Campana, R. J.

    1986-01-01

    Proposed thermoelectromagnetic pump for liquid metal powered by waste heat; needs no battery, generator, or other external energy source. Pump turns part of heat in liquid metal into pumping energy. In combination with primary pump or on its own, thermoelectric pump circulates coolant between reactor and radiator. As long as there is decay heat to be removed, unit performs function.

  19. Water Treatment Technology - Pumps.

    Science.gov (United States)

    Ross-Harrington, Melinda; Kincaid, G. David

    One of twelve water treatment technology units, this student manual on pumps provides instructional materials for three competencies. (The twelve units are designed for a continuing education training course for public water supply operators.) The competencies focus on the following areas: types of pumps in plant and distribution systems, pump…

  20. Portable Heat Pump Testing Device

    Directory of Open Access Journals (Sweden)

    Kłosowiak R.

    2015-08-01

    Full Text Available The aim of this paper is to present the design and working principle of a portable testing device for heat pumps in the energy recirculation system. The presented test stand can be used for any refrigerating/reverse flow cycle device to calculate the device energy balance. The equipment is made of two portable containers of the capacity of 250 liters to simulate the air heat source and ground heat source with a system of temperature stabilization, compressor heat pump of the coefficient of performance (COP of = 4.3, a failsafe system and a control and measurement system.

  1. GEOTHERMAL HEAT PUMP GROUTING MATERIALS

    Energy Technology Data Exchange (ETDEWEB)

    ALLAN,M.

    1998-04-01

    The thermal conductivity of cementitious grouts has been investigated in order to determine suitability of these materials for grouting vertical boreholes used with geothermal heat pumps. The roles of mix variables such as water/cement ratio, sand/cement ratio and superplasticizer dosage were measured. The cement-sand grouts were also tested for rheological characteristics, bleeding, permeability, bond to HDPE pipe, shrinkage, coefficient of thermal expansion, exotherm, durability and environmental impact. This paper summarizes the thermal conductivity, permeability, bonding and exotherm data for selected cementitious grouts. The theoretical reduction in bore length that could be achieved with the BNL-developed cement-sand grouts is examined. Finally, the FY 98 research and field trials are discussed.

  2. Geothermal heat pump grouting materials

    Energy Technology Data Exchange (ETDEWEB)

    Allan, M.

    1998-08-01

    The thermal conductivity of cementitious grouts has been investigated in order to determine suitability of these materials for grouting vertical boreholes used with geothermal heat pumps. The roles of mix variables such as water/cement ratio, sand/cement ratio and superplasticizer dosage were measured. The cement-sand grouts were also tested for rheological characteristics, bleeding, permeability, bond to HDPE pipe, shrinkage, coefficient of thermal expansion, exotherm, durability and environmental impact. This paper summarizes the thermal conductivity, permeability, bonding and exotherm data for selected cementitious grouts. The theoretical reduction in bore length that could be achieved with the BNL-developed cement-sand grouts is examined. Finally, the FY 98 research and field trials are discussed.

  3. HEAT PUMP APPLICATION IN FOOD TECHNOLOGY

    Directory of Open Access Journals (Sweden)

    Péter Korzenszky

    2012-10-01

    Full Text Available The economy of food technologies is greatly influenced by their energy consumption. Almost no operation or procedure exists that could be executed without the need for electricity. At the same time, several technologies require direct or indirect input of thermal energy as well. An example to quote is the heating of the raw materials of food industry or the pasteurisation or sterilisation of finished products, but heating the production rooms or cleaning or washing the machinery also require energy. Needless to say food industry plants constantly seek ways to improve their energy efficiency such as the reintroduction of waste heat into the technology and the use of renewables. Heat recovering heat exchangers are used in the pasteurisation technology of milk. In case of lower temperatures, however, simple heat exchangers are of no use. Few practical examples of heat recovery obtained upon cooling products or raw materials exist in the food industry even though the possibility of this is available using heat pumps. Heat pumps have been successfully applied to heat apartments with thermal energy recovered from the cooling of soils, water or air or to utilise the excess heat of thermal spring waters. Our present article introduces the application possibility in a soda water plant, fundamentally determining the quality of soda water and showing an example of rational utilisation.

  4. Potential of the heat pump; Potenziale der Waermepumpe

    Energy Technology Data Exchange (ETDEWEB)

    Flade, F. [Bundesverband WaermePumpe (BWP) e.V., Muenchen (Germany)

    2005-07-01

    Heat pumps have been around for years. They are a mature and economically efficient heating technology which will reduce primary energy consumption and CO2 emissions quickly and sustainably. In 2002, 251,000 million l of heating oil and 289,000 million cubic metres of gas were consumed for heating in Germany, which might have been greatly reduced with heat pumps. At a seasonal performance factor of 4.5 as is common in groundwater and ground source heat pumps, heat pumps will produce 40 percent less CO2 than gas-fuelled high-efficiency boilers. At 'normal' values of 3.5 which are more or less standard values for air-to-water heat pumps, CO2 emissions will be reduced by 30 percent. The heat pump is an ecologically effective and economically efficient alternative to conventional heating systems. (orig.)

  5. Regional Climate Zone Modeling of a Commercial Absorption Heat Pump Hot Water Heater Part 1: Southern and South Central Climate Zones

    Energy Technology Data Exchange (ETDEWEB)

    Geoghegan, Patrick J [ORNL; Shen, Bo [ORNL; Keinath, Christopher M. [Stone Mountain Technologies, Inc., Johnson City; Garrabrant, Michael A. [Stone Mountain Technologies, Inc., Johnson City

    2016-01-01

    Commercial hot water heating accounts for approximately 0.78 Quads of primary energy use with 0.44 Quads of this amount from natural gas fired heaters. An ammonia-water based commercial absorption system, if fully deployed, could achieve a high level of savings, much higher than would be possible by conversion to the high efficiency nonheat-pump gas fired alternatives. In comparison with air source electric heat pumps, the absorption system is able to maintain higher coefficients of performance in colder climates. The ammonia-water system also has the advantage of zero Ozone Depletion Potential and low Global Warming Potential. A thermodynamic model of a single effect ammonia-water absorption system for commercial space and water heating was developed, and its performance was investigated for a range of ambient and return water temperatures. This allowed for the development of a performance map which was then used in a building energy modeling software. Modeling of two commercial water heating systems was performed; one using an absorption heat pump and another using a condensing gas storage system. The energy and financial savings were investigated for a range of locations and climate zones in the southern and south central United States. A follow up paper will analyze northern and north/central regions. Results showed that the system using an absorption heat pump offers significant savings.

  6. 采用热泵技术回收工业循环水余热%Recovery of Waste Heat from Industrial Circulating Water Using Heat Pump

    Institute of Scientific and Technical Information of China (English)

    闫晓燕

    2014-01-01

    如何利用工业余热,特别是30~50℃低温余热,是行业内普遍关注的问题,热泵技术在这方面具有很大潜力,是一项值得推广的节能技术。介绍了太钢自备电厂采用热泵技术回收工业循环水余热的方案与效℃计算。%It has been an issue of common concern in the steel sector to recover indus-trial waste heat, especially 30-50℃ low temperature waste heat. With great potential in this field the heat pump is of an energy saving technology deserving promotion. The project of recovering waste heat from industrial circulating water using heat pump technology at the self-supply power plant of Taiyuan Steel is introduced and economic benefit of the project is calculated as well.

  7. A Numerical Study on System Performance of Groundwater Heat Pumps

    Directory of Open Access Journals (Sweden)

    Jin Sang Kim

    2015-12-01

    Full Text Available Groundwater heat pumps have energy saving potential where the groundwater resources are sufficient. System Coefficients of Performance (COPs are measurements of performance of groundwater heat pump systems. In this study, the head and power of submersible pumps, heat pump units, piping, and heat exchangers are expressed as polynomial equations, and these equations are solved numerically to determine the system performance. Regression analysis is used to find the coefficients of the polynomial equations from a catalog of performance data. The cooling and heating capacities of water-to-water heat pumps are determined using Energy Plus. Results show that system performance drops as the water level drops, and the lowest flow rates generally achieve the highest system performance. The system COPs are used to compare the system performance of various system configurations. The groundwater pumping level and temperature provide the greatest effects on the system performance of groundwater heat pumps along with the submersible pumps and heat exchangers. The effects of groundwater pumping levels, groundwater temperatures, and the heat transfer coefficient in heat exchanger on the system performance are given and compared. This analysis needs to be included in the design process of groundwater heat pump systems, possibly with analysis tools that include a wide range of performance data.

  8. Carbon dioxide heat pump for dual-temperature drinking fountain

    Institute of Scientific and Technical Information of China (English)

    杨大章; 吕静; 何哲彬; 黄秀芝

    2009-01-01

    Carbon dioxide trans-critical heat pump system for heating and cooling water was designed,and its thermodynamic steady-state concentration model was established. Based on the steady-state model,parameters of the carbon dioxide trans-critical heat pump were calculated by computer programming. According to these parameters,the effects and application prospect of the heat pump system were analyzed for dual-temperature drinking fountains.

  9. Absorption-heat-pump system

    Science.gov (United States)

    Grossman, G.; Perez-Blanco, H.

    1983-06-16

    An improvement in an absorption heat pump cycle is obtained by adding adiabatic absorption and desorption steps to the absorber and desorber of the system. The adiabatic processes make it possible to obtain the highest temperature in the absorber before any heat is removed from it and the lowest temperature in the desorber before heat is added to it, allowing for efficient utilization of the thermodynamic availability of the heat supply stream. The improved system can operate with a larger difference between high and low working fluid concentrations, less circulation losses, and more efficient heat exchange than a conventional system.

  10. Multistage quantum absorption heat pumps

    Science.gov (United States)

    Correa, Luis A.

    2014-04-01

    It is well known that heat pumps, while being all limited by the same basic thermodynamic laws, may find realization on systems as "small" and "quantum" as a three-level maser. In order to quantitatively assess how the performance of these devices scales with their size, we design generalized N-dimensional ideal heat pumps by merging N -2 elementary three-level stages. We set them to operate in the absorption chiller mode between given hot and cold baths and study their maximum achievable cooling power and the corresponding efficiency as a function of N. While the efficiency at maximum power is roughly size-independent, the power itself slightly increases with the dimension, quickly saturating to a constant. Thus, interestingly, scaling up autonomous quantum heat pumps does not render a significant enhancement beyond the optimal double-stage configuration.

  11. Economics of heat pump systems for simultaneous heating and cooling

    Energy Technology Data Exchange (ETDEWEB)

    Ghosh, S.; Devotta, S.; Patwardhan, V.S.

    1987-01-01

    Heat pumps can be incorporated advantageously into processes which require simultaneously both cooling and heating. The economics of heat pumps in India for simultaneous heat and cooling is assessed with respect to process, design and economic parameters. For the typical conditions of various parameters in India, a heat pump system for simultaneous heating and cooling is very attractive.

  12. Experiences with large heat pumps for space heating. Erfaringer med store varmepumper til rumopvarmning

    Energy Technology Data Exchange (ETDEWEB)

    Willumsen, O.

    1984-01-01

    In Denmark, only a moderate number of large heat pumps has been installed. Large heat pumps are in this context defined as heat pumps with a heat output exceeding 50 kW. Heat sources for these heat pumps are - to some extent - the same as for smaller heat pumps, i.e. outdoor air, exhaust air, soil and ground water. The use of sewage water, water from lakes or seawater also is rather commen. Besides, more special heat sources based on industrial waste heat are being utilized. The report primarily deals with heat pumps using the most common heat sources. This means that industrial heat pumps are not included in this report. In a few cases it has been considered appropriate to include heat pumps with a heat output smaller than 50 kW, when the experiences from these installations are considered relevant for larger plants. Some of the main findings of the survey are: - When designing heat pump installations, greater attention should be paid towards a more precise evaluation of the annual energy demand of the heat load. - Consulting firms generally have inadequate knowledge of the practical attainable seasonal COP's. - The energy surveillance equipment is insufficient in many installations - or is missing completely. - Salt-based antifreeze solutions should normally be avoided. - Utilizing ground water as a heat source can be problematic due to fouling problems or corrosion damages.

  13. Replacing an electrical heating system by an air/water heat pump; Remplacement du chauffage electrique par une installation PAC air/eau (pompe a chaleur)

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2004-07-01

    A group of thirteen houses in Plan-les-Ouates (southwestern Switzerland) constructed in 1985 was originally equipped with direct electric heaters. Their inhabitants complained about high electricity bills and bad thermal comfort due to uneven room temperatures and insufficient amounts of warm water. A group of specialists from the Swiss Federal Office of Energy, the energy service of the canton of Geneva and from an engineering company studied the case and suggested to replace the direct electric heating system by an air to water heat pump. Seven owners have decided for this modification and the retrofit has been made in autumn 2000. The paper presents the results of performance measurements, operating experience gained and economic considerations for the years 2001, 2002 and 2003 for six installations. The average coefficients of performance ranged from 2.3 to 2.9.

  14. Open cycle vapor compression heat pump

    Science.gov (United States)

    Sakhuja, R.; Becker, F. E.

    1980-07-01

    A compressor test facility was built incorporating a screw compressor modified for steam service. The compressor was tested over a wide range of operating conditions with experimental results showing excellent agreement with predicted performance. The compressor operation with wet steam and water injection was completely satisfactory, demonstrating its suitability for use in a steam heat pump system.

  15. Some comments on air source heat pumps

    Energy Technology Data Exchange (ETDEWEB)

    Haukaas, H.T. (Norges tekniska hoegskola, Trondheim (Norway)). Institutt for kuldeteknikk

    1982-02-01

    Some vital conditions regarding air/water heat pumps are analyzed by use of computer simulators of a middle sized heat pump system. Heat pumps, and specially air source units, should always be used in combination with conventional heating equipment for peak load supply. (Bivalent systems). The economic optimum heat pump capacity compared to system design load is strongly related to the climate. At typical coastal conditions a ratio of 60-70 per cent is found favourable, while 40-50 per cent will be the correct choice for Norwegian inland area. Analysis of the evaporator shows that it should be designed for 120-130 W/m/sup 2/ specific load and 2-2.2 m/s inlet air velocity, which is well below common practice in designing standard air coolers. The condenser LMTD (logaritmic mean temperature difference) should be chosen about 4 degrees C, while the corresponding 'sellers optimum' is calculated to app. 8.5 degrees C. The difference in total heating costs between systems fully designed according to 'sellers optimum' and 'buyers optimum' respectively is found to be about 0.01 Nkr/kWh.

  16. Magnetic Heat Pump Containing Flow Diverters

    Science.gov (United States)

    Howard, Frank S.

    1995-01-01

    Proposed magnetic heat pump contains flow diverters for suppression of undesired flows. If left unchecked, undesired flows mix substantial amounts of partially heated and partially cooled portions of working fluid, effectively causing leakage of heat from heated side to cooled side. By reducing leakage of heat, flow diverters increase energy efficiency of magnetic heat pump, potentially offering efficiency greater than compressor-driven refrigerator.

  17. Magnetic Heat Pump Containing Flow Diverters

    Science.gov (United States)

    Howard, Frank S.

    1995-01-01

    Proposed magnetic heat pump contains flow diverters for suppression of undesired flows. If left unchecked, undesired flows mix substantial amounts of partially heated and partially cooled portions of working fluid, effectively causing leakage of heat from heated side to cooled side. By reducing leakage of heat, flow diverters increase energy efficiency of magnetic heat pump, potentially offering efficiency greater than compressor-driven refrigerator.

  18. Ground water heat pumps and cooling with ground water basins as seasonal storage; Grundvandsvarmepumper og -koeling med grundvandsmagasiner som saesonlager

    Energy Technology Data Exchange (ETDEWEB)

    2008-04-15

    Ground water temperature is constant all the year round, in Denmark approximately 9 deg. C, which is ideal for a number of cooling purposes including cooling of buildings. The structures in which the ground water flows (sand, gravel and chalk) are efficient for storing coldness and heat over longer periods. By using seasonal storage of low-temperature heat and coldness in ground water layers close to the terrain it is feasible to reach profitable energy savings of up to 90% for cooling and heating of e.g. hotels, airports, shopping malls, office buildings and other larger buildings. At the same time the large energy savings means major reduction of CO{sub 2} emissions. (BA)

  19. Ground water heat pumps and cooling with ground water basins as seasonal storage; Grundvandsvarmepumper og -koeling med grundvandsmagasiner som saesonlager

    Energy Technology Data Exchange (ETDEWEB)

    2008-04-15

    Ground water temperature is constant all the year round, in Denmark approximately 9 deg. C, which is ideal for a number of cooling purposes including cooling of buildings. The structures in which the ground water flows (sand, gravel and chalk) are efficient for storing coldness and heat over longer periods. By using seasonal storage of low-temperature heat and coldness in ground water layers close to the terrain it is feasible to reach profitable energy savings of up to 90% for cooling and heating of e.g. hotels, airports, shopping malls, office buildings and other larger buildings. At the same time the large energy savings means major reduction of CO{sub 2} emissions. (BA)

  20. Bounding Limitations in the Practical Design of Adsorption Heat Pump Water Heaters

    Energy Technology Data Exchange (ETDEWEB)

    Ally, Moonis Raza [ORNL; Sharma, Vishaldeep [ORNL; Gluesenkamp, Kyle R [ORNL

    2016-01-01

    The boundary temperatures for any sorption-based technology can be estimated on the basis of Trouton s hypothesis that isosteres, extrapolated to infinite pressure (or analogously to infinite temperature) meet at a single point. In this paper we discuss the consequences of this hypothesis for many sorption devices that are thermally operated, suitable for exploiting renewable energy resources, or making better use of high or low level thermal energy. Trouton s hypothesis is independent of the working fluids making it particularly useful to both liquid-vapor and solid-vapor systems. We exemplify the use of the derived boundary temperatures derived from Trouton s hypothesis to important processes such as ice making, space cooling in hot climates, deep freezing, and residential hot water production. The boundary temperatures help determine which sorption or solar heating technology may be better suited to serve the given application, or whether it is beyond the scope of sorption systems.

  1. Geothermal heat in a heat pump use

    Science.gov (United States)

    Pavlova, A.; Hansen, J.; Obermeyer, H.; Pavlova, I.

    2016-09-01

    The considered innovative technology proposes to use alternative energy sources for the process efficiency in low-height construction. The world economy depends on price rises for energy sources and the danger of environmental pollution increases. Geothermal energy is the basic resource saving and environmentally safe renewable heat source that is characterized by inexhaustibility, permanent all the-year-round use, universal prevalence of resources and the ability to replace considerable volumes of traditional energy carriers. The expediency and power efficiency to apply a heat pump with the use of geothermal heat is proved for low-height construction.

  2. Staged regenerative sorption heat pump

    Science.gov (United States)

    Jones, Jack A. (Inventor)

    1995-01-01

    A regenerative adsorbent heat pump process and system for cooling and heating a space. A sorbent is confined in a plurality of compressors of which at least four are first stage and at least four are second stage. The first stage operates over a first pressure region and the second stage over a second pressure region which is higher than the first. Sorbate from the first stage enters the second stage. The sorbate loop includes a condenser, expansion valve, evaporator and the compressors. A single sorbate loop can be employed for single-temperature-control such as air conditioning and heating. Two sorbate loops can be used for two-temperature-control as in a refrigerator and freezer. The evaporator temperatures control the freezer and refrigerator temperatures. Alternatively the refrigerator temperature can be cooled by the freezer with one sorbate loop. A heat transfer fluid is circulated in a closed loop which includes a radiator and the compressors. Low temperature heat is exhausted by the radiator. High temperature heat is added to the heat transfer fluid entering the compressors which are desorbing vapor. Heat is transferred from compressors which are sorbing vapor to the heat transfer fluid, and from the heat transfer fluid to the compressors which are desorbing vapor. Each compressor is subjected to the following phases, heating to its highest temperature, cooling down from its highest temperature, cooling to its lowest temperature, and warming up from its lowest temperature. The phases are repeated to complete a cycle and regenerate heat.

  3. Carbon Dioxide Absorption Heat Pump

    Science.gov (United States)

    Jones, Jack A. (Inventor)

    2002-01-01

    A carbon dioxide absorption heat pump cycle is disclosed using a high pressure stage and a super-critical cooling stage to provide a non-toxic system. Using carbon dioxide gas as the working fluid in the system, the present invention desorbs the CO2 from an absorbent and cools the gas in the super-critical state to deliver heat thereby. The cooled CO2 gas is then expanded thereby providing cooling and is returned to an absorber for further cycling. Strategic use of heat exchangers can increase the efficiency and performance of the system.

  4. Carbon Dioxide Absorption Heat Pump

    Science.gov (United States)

    Jones, Jack A. (Inventor)

    2002-01-01

    A carbon dioxide absorption heat pump cycle is disclosed using a high pressure stage and a super-critical cooling stage to provide a non-toxic system. Using carbon dioxide gas as the working fluid in the system, the present invention desorbs the CO2 from an absorbent and cools the gas in the super-critical state to deliver heat thereby. The cooled CO2 gas is then expanded thereby providing cooling and is returned to an absorber for further cycling. Strategic use of heat exchangers can increase the efficiency and performance of the system.

  5. About Variable Speed Heating and Cooling Pumps

    OpenAIRE

    Cătălin Popovici; Jan Ignat

    2009-01-01

    The present work has the purpose of underlying the advantages of variable speed heating and cooling pumps use for the perspective of general and particular pumping costs and efficiency. The study approaches comparisons between constant flow pumps and variable flow pumps in different given situations and comparatively analyses the pumping costs.

  6. Air-To-Water Heat Pumps with Radiant Delivery in Low Load Homes: Tucson, Arizona and Chico, California (Fact Sheet)

    Energy Technology Data Exchange (ETDEWEB)

    2013-11-01

    Space conditioning represents nearly 50% of average residential household energy consumption, highlighting the need to identify alternative cost-effective, energy-efficient cooling and heating strategies. As homes are better built, there is an increasing need for strategies that are particularly well suited for high performance, low load homes. ARBI researchers worked with two test homes in hot-dry climates to evaluate the in-situ performance of air-to-water heat pump (AWHP) systems, an energy efficient space conditioning solution designed to cost-effectively provide comfort in homes with efficient, safe, and durable operation. Two monitoring projects of test houses in hot-dry climates were initiated in 2010 to test this system. Both systems were fully instrumented and have been monitored over one year to capture complete performance data over the cooling and heating seasons. Results are used to quantify energy savings, cost-effectiveness, and system performance using different operating modes and strategies. A calibrated TRNSYS model was developed and used to evaluate performance in various climate regions. This strategy is most effective in tight, insulated homes with high levels of thermal mass (i.e. exposed slab floors).

  7. 地下水源热泵系统热平衡模拟三维数值模型%Three-dimensional numerical model for heat balance simulation of ground-water heat pump

    Institute of Scientific and Technical Information of China (English)

    骆祖江; 李伟; 王琰; 张德忠; 方连育

    2014-01-01

    In order to simulate and predict the change law of heat balance accurately and avoid heat penetration phenomenon during the groundwater heat pump operation, a three dimensional coupling numerical model of groundwater seepage and thermal transport was established and applied to the demonstration project of groundwater heat pump system in Zhengding, Hebei province. The model was based on the groundwater seepage theory, saturated water-bearing medium thermal transport theory and Terzaghi effective stress principle, combined with the design scheme and operation situation of groundwater heat pump, the future heat balance development tendency of groundwater heat pump system under three different conditions was forecasted and analyzed. The water temperature difference between the pumping well and recharge well reduced by 20%(eight degree centigrade) or increased by 20%(twelve degree centigrade) was the first condition which means the cooling and heating load was kept constant. Second condition was the water temperature difference between pumping well and recharge well confirmed and the circulating water volume increased by 20%, or the volume of circulating water kept constant and water temperature difference between pumping well and recharge well increased 20%, which means the cooling and heating load was increased. Meanwhile, in the third condition, the cooling and heating load was reduced. The water temperature difference between the pumping well and recharge well was confirmed and the volume of circulating water reduced 20%, or the water temperature difference between pumping well and recharge well reduced 20%while the circulating water volume kept constant. It was shown that there is a heat penetration phenomenon between the pumping well and recharge well in the demonstration project under the condition of design scheme, which has one pumping well and one recharge well. When the cooling and heating load of the groundwater heat pump system is confirmed, increasing 20

  8. Motionless heat pump - A new application of thermal transpiration

    Science.gov (United States)

    Kugimoto, K.; Hirota, Y.; Kizaki, Y.

    2016-11-01

    A motionless heat pump system using a combination of thermal transpiration flow of a rarefied gas and a phase change of water has been proposed. This system consists primarily of a thermal transpiration pump, referred to as a Knudsen pump, and two chambers filled with water and water vapor, respectively. The Knudsen pump moves water vapor from one chamber to the other. The pressure drop in the outflow chamber promotes the evaporation of water and heat absorption, whereas the pressure increase in the inflow chamber promotes vapor condensation and heat generation. The maximum pressure difference and mass flow rate obtained by a Knudsen pump composed of a glass fiber filter were 57.6 Pa and 0.0484 mg/s/cm2, respectively, at a temperature difference across the filter of 120 K between the two chambers. The vapor delivery capacity of this pump was also measured experimentally.

  9. Maldistribution in airewater heat pump evaporators. Part 1: Effects on evaporator, heat pump and system level

    DEFF Research Database (Denmark)

    Mader, Gunda; Palm, Björn; Elmegaard, Brian

    2015-01-01

    This paper presents an approach to quantify the effect of evaporator maldistribution onoperating costs of air-water heat pumps. In the proposed simulation model maldistributionis induced by two parameters describing refrigerant phase and air flow distribution.Annual operating costs are calculated...... based on heat pump performance at distinct operatingconditions. Results show that percentage increase of operating costs is similar for thethree considered climate zones, even though the effect of maldistribution on heat pumpperformance varies with operating conditions. Differences in terms of absolute...

  10. Experimental Results and Model Calculations of a Hybrid Adsorption-Compression Heat Pump Based on a Roots Compressor and Silica Gel-Water Sorption

    Energy Technology Data Exchange (ETDEWEB)

    Van der Pal, M.; De Boer, R.; Wemmers, A.K.; Smeding, S.F.; Veldhuis, J.B.J.; Lycklama a Nijeholt, J.A.

    2013-10-15

    Thermally driven sorption systems can provide significant energy savings, especially in industrial applications. The driving temperature for operation of such systems limits the operating window and can be a barrier for market-introduction. By adding a compressor, the sorption cycle can be run using lower waste heat temperatures. ECN has recently started the development of such a hybrid heat pump. The final goal is to develop a hybrid heat pump for upgrading lower (<100C) temperature industrial waste heat to above pinch temperatures. The paper presents the first measurements and model calculations of a hybrid heat pump system using a water-silica gel system combined with a Roots type compressor. From the measurements can be seen that the effect of the compressor is dependent on where in the cycle it is placed. When placed between the evaporator and the sorption reactor, it has a considerable larger effect compared to the compressor placed between the sorption reactor and the condenser. The latter hardly improves the performance compared to purely heat-driven operation. This shows the importance of studying the interaction between all components of the system. The model, which shows reasonable correlation with the measurements, could proof to be a valuable tool to determine the optimal hybrid heat pump configuration.

  11. Geothermal Heat Pump Benchmarking Report

    Energy Technology Data Exchange (ETDEWEB)

    None

    1997-01-17

    A benchmarking study was conducted on behalf of the Department of Energy to determine the critical factors in successful utility geothermal heat pump programs. A Successful program is one that has achieved significant market penetration. Successfully marketing geothermal heat pumps has presented some major challenges to the utility industry. However, select utilities have developed programs that generate significant GHP sales. This benchmarking study concludes that there are three factors critical to the success of utility GHP marking programs: (1) Top management marketing commitment; (2) An understanding of the fundamentals of marketing and business development; and (3) An aggressive competitive posture. To generate significant GHP sales, competitive market forces must by used. However, because utilities have functioned only in a regulated arena, these companies and their leaders are unschooled in competitive business practices. Therefore, a lack of experience coupled with an intrinsically non-competitive culture yields an industry environment that impedes the generation of significant GHP sales in many, but not all, utilities.

  12. Design of Dynamic Wind Pump Circulating Water Heat Recovery%动力风泵房循环水余热回收方案设计

    Institute of Scientific and Technical Information of China (English)

    宋学良; 宋玉强

    2014-01-01

    介绍了动力风泵房每年有大量的工业余热为没经过处理直接排放,造成能源的浪费,以及其解决的思路:利用水源热泵吸收动力风泵房中产生的余热来加热水源,变成洗浴用水,从而达到节能减排的目的。%This article introduces that there is much industrial waste heat in the dynamic wind house which is directly discharge without treating, which produces energy wasting, and there is also the solution-making use of waste heat generated from dynamic wind pump house to heat water with water source heat pump unit, which can achieve the goal of energy conservation and emission reduction.

  13. A simplified heat pump model for use in solar plus heat pump system simulation studies

    OpenAIRE

    Perers, Bengt; Anderssen, Elsa; Nordman, Roger; Kovacs, Peter

    2012-01-01

    Solar plus heat pump systems are often very complex in design, with sometimes special heat pump arrangements and control. Therefore detailed heat pump models can give very slow system simulations and still not so accurate results compared to real heat pump performance in a system. The idea here is to start from a standard measured performance map of test points for a heat pump according to EN 14825 and then determine characteristic parameters for a simplified correlation based model of the he...

  14. Sorption Refrigeration / Heat Pump Cycles

    Science.gov (United States)

    Saha, Bidyut Baran; Alam, K. C. Amanul; Hamamoto, Yoshinori; Akisawa, Atsushi; Kashiwagi, Takao

    Over the past few decades there have been considerable efforts to use adsorption (solid/vapor) for cooling and heat pump applications, but intensified efforts were initiated only since the imposition of international restrictions on the production and use of CFCs (chlorofluorocarbons) and HCFCs (hydrochlorofluorocarbons). Up to now, only the desiccant evaporative cooling system of the open type has achieved commercial use, predominantly in the United States. Closed-type adsorption refrigeration and heat pump systems are rarely seen in the market, or are still in the laboratory testing stage. Promising recent development have been made in Japan for the use of porous metal hydrides and composite adsorbents. In this paper, a short description of adsorption theories along with an overview of present status and future development trends of thermally powered adsorption refrigeration cycles are outlined putting emphasis on experimental achievements. This paper also addressed some advanced absorption cycles having relatively higher COP, and also summarizes fundamental concepts of GAX cycles and various GAX cycles developed for heat pump applications.

  15. 水源热泵技术在铀矿山应用的探讨%Discussion on application of water source heat pump technology to uranium mines

    Institute of Scientific and Technical Information of China (English)

    安强

    2011-01-01

    Application of water source heat pump units in recovering waste heat from uranium mines is discussed, and several forms of waste heat recovery are introduced. The problems in the application of water source heat pump technology are analyzed. Analysis results show that the water source heat pump technology has broad application prospects in uranium mines, and it is a way to exchange existing structure of heat and cold sources in uranium mines.%探讨水源热泵机组在回收铀矿山废热中的应用,介绍其回收废热的几种形式,同时分析其在铀矿山应用存在的问题.研究分析表明,水源热泵在铀矿山具有广阔的应用前景,是改变矿山现有冷热源结构的一条理想出路.

  16. Refrigerant Selection for Cascade Water-to-water Heat Pump%复叠式水水热泵的制冷剂筛选

    Institute of Scientific and Technical Information of China (English)

    赵海波; 杨昭

    2012-01-01

    结合我国现行制冷剂标准,按照环境相容性、安全性、热工循环性能原则进行了高温复叠式热泵循环的制冷剂筛选,对不同制冷剂组合进行了计算和分析.结果表明,高低温侧制冷剂可采用R245fa/R134a、R245fa/R420A、R245fa/R413A、R245ca/R420A等组合.若进一步考虑制冷剂获得的容易程度、经济性等因素时,可选择R245fa/R134a组合.%Based on China National Standard-Number Designation and Safety Classification of Refrigerants, refrigerant for the cascade water-to-water heat pump were selected according to principles of environmental-friendly, safety and thermodynamic cycle performances. Different refrigerant combinations for high- and low-temperature cycles in the cascade heat pump were calculated and compared. Results show that combinations of R245fa/R134a, R245fa/R420A, R245fa/R413A, R245ca/R420A are better for the cascade heat pump. It also shows that, considering easy access and economy of refrigerants, R245fa/R134a combination will be a better choice.

  17. A novel design method for ground source heat pump

    Directory of Open Access Journals (Sweden)

    Dong Xing-Jie

    2014-01-01

    Full Text Available This paper proposes a novel design method for ground source heat pump. The ground source heat pump operation is controllable by using several parameters, such as the total meters of buried pipe, the space between wells, the thermal properties of soil, thermal resistance of the well, the initial temperature of soil, and annual dynamic load. By studying the effect of well number and well space, we conclude that with the increase of the well number, the inlet and outlet water temperatures decrease in summer and increase in winter, which enhance the efficiency of ground source heat pump. The well space slightly affects the water temperatures, but it affects the soil temperature to some extent. Also the ground source heat pump operations matching with cooling tower are investigated to achieve the thermal balance. This method greatly facilitates ground source heat pump design.

  18. 某商业建筑地下水源热泵系统设计%The System Design of Ground Water Heat Pumps in a Commercial Building

    Institute of Scientific and Technical Information of China (English)

    高亮

    2014-01-01

    地下水源热泵是地源热泵的一种形式。与土壤源热泵比,其具有投资小、运行费用低的特点,因此在工程实际中可推广性更强。文章以某商业建筑为例,以建筑形式、面积为基础,进行了水源热泵系统设计,并对工程投资和运行费用进行了估算。%Ground water heat pump is a form of ground source heat pumps, and compare with the soil source heat pump, its investment smal and operating cost low, so it has stronger generalization in engineering practice. This article takes a commercial building as example and based on the architectural form and area, designs the water heat pump system and estimate the engineering investment and operation cost.

  19. 新型节能型两段加热热泵开水器的研制%Research and manufacture of a new type energy-saving heat pump drinking water boiler with two-stages heating

    Institute of Scientific and Technical Information of China (English)

    金云学; 江勇; 成志方

    2011-01-01

    分析了电加热开水器的现状和空气源热泵优点,以及热泵制取高温热水存在的问题.提出将空气源热泵和电加热开水器相结合的设想,并与先进的步进补水技术相结合,设计了一种新型节能型开水器,并阐述了其设计简图、工作原理、加热模式、补水方式、除霜控制,分析了其低温段及整体能效,体现了其节能效果.%The status of electric heating drinking water boiler and the advantages of air source heat pump are analyzed, and the problems of making high temperature hot water with heat pump are discussed. Based on the idea of combining air source heat pump and electric heating drinking water boiler, a new type energy-saving drinking water boiler is presented with the advanced technology of step water-supply. The details of design sketch, working principle, heating mode, water supply method and defrost control are described. Furthermore, low-temperature part and the overall energy efficiency of the drinking water boiler are analyzed. Also, its energy-saving effect is reflected.

  20. Magnetocaloric heat pump device, a heating or cooling system and a magnetocaloric heat pump assembly

    DEFF Research Database (Denmark)

    2014-01-01

    The invention provides a magnetocaloric heat pump device, comprising a magnetocaloric bed; a magnetic field source, the magnetocaloric bed and the magnetic field source being arranged to move relative to each other so as to generate a magnetocaloric refrigeration cycle within the heat pump, wherein...

  1. Absorption Cycle Heat Pump Model for Control Design

    DEFF Research Database (Denmark)

    Vinther, Kasper; Just Nielsen, Rene; Nielsen, Kirsten Mølgaard

    2015-01-01

    Heat pumps have recently received increasing interest due to green energy initiatives and increasing energy prices. In this paper, a nonlinear dynamic model of a single-effect LiBr-water absorption cycle heat pump is derived for simulation and control design purposes. The model is based...... on an actual heat pump located at a larger district heating plant. The model is implemented in Modelica and is based on energy and mass balances, together with thermodynamic property functions for LiBr and water and staggered grid representations for heat exchangers. Model parameters have been fitted...... to operational data and different scenarios are simulated to investigate the operational stability of the heat pump. Finally, this paper provides suggestions and examples of derivation of lower order linear models for control design. © Copyright IEEE - All rights reserved....

  2. A Comparative Cycle and Refrigerant Simulation Procedure Applied on Air-Water Heat Pumps

    DEFF Research Database (Denmark)

    Mader, Gunda; Palm, Björn; Elmegaard, Brian

    2012-01-01

    the evaluation to a single set of components. A special focus is on the heat exchanger sizes as a dominant influence on the cycle efficiency. Varying sizes are taken into account using a design of experiment factorization to determine a quadratic regression model for the energy efficiency. In combination...... with component cost correlations a constrained non-linear optimization problem is formulated and solved. Strengths and weaknesses of the proposed procedure are discussed in regard of its ability to help in systematically identifying promising combinations of cycle layout and refrigerant....

  3. Control strategy research of variable flow at heat source side for water source heat pump%水源热泵系统热源侧变流量控制策略研究

    Institute of Scientific and Technical Information of China (English)

    蒋小强; 龙惟定; 李敏

    2012-01-01

    分析水源热泵系统供热运行的技术经济性.建立适用于TRNSYS软件模拟的水源热泵系统模型,针对不同水源温度通过改变热源侧水流量方式优化运行.比较水源热泵系统、燃气和燃油3种供热方式的运行经济性,结果表明,不同水源温度下的最佳供热方式不同.%Technical economy analysis of water source heat pump system is done in heating operation. The model of water source heat pump is established at TRNSYS platform, the optimal operation under different temperature of source water are carried by changing the water flow of heat source side. The running economy of heating by wate soure heat pump system, the combustion gas or oil is compared, the best heating mode is obtained at different water source temperature.

  4. ENERGY STAR Certified Geothermal Heat Pumps

    Science.gov (United States)

    Certified models meet all ENERGY STAR requirements as listed in the Version 3.0 ENERGY STAR Program Requirements for Geothermal Heat Pumps that are effective as of January 1, 2012. A detailed listing of key efficiency criteria are available at http://www.energystar.gov/index.cfm?c=geo_heat.pr_crit_geo_heat_pumps

  5. Applicability of sewage heat pump air-conditioning system

    Institute of Scientific and Technical Information of China (English)

    陈金华; 刘猛; 刘勇; 靳鸣; 陈洁

    2009-01-01

    A sewage heat pump system and its application based on a project in Chongqing,China,were discussed. Based on the sewage conditions,a feasibility analysis of the sewage heat pump air conditioning system was conducted. The theoretical and quantitative calculations indicate that sewage flux in the city sewage main pipe in the project can satisfy heat exchange requirements,and taking water from the pipes has relatively small influence on the pipe net in summer and winter. The sewage heat pump air-conditioning system can save 21.5% operating cost in one year,which is energy efficient and environmentally friendly.

  6. New composite sorbents of water and ammonia for chemical and adsorption heat pumps

    Science.gov (United States)

    Aristov, Yu. I.; Vasiliev, L. L.

    2006-11-01

    New sorbents of water and ammonia — “salt in porous matrix” composites and “salt on fiber” composites — have been reviewed. The possibility of “constructing” the sorption properties of the composites at the nanophase level by varying their composition, the size of the host-matrix pores, and synthesis conditions has been shown. The application of the new materials in adsorption refrigerating devices has been considered.

  7. Central model predictive control of a group of domestic heat pumps, case study for a small district

    NARCIS (Netherlands)

    Leeuwen, van R.P.; Fink, J.; Smit, G.J.M.; Helfert, Markus; Krempels, Karl-Heinz; Donnellan, Brian; Klein, Cornel

    2015-01-01

    In this paper we investigate optimal control of a group of heat pumps. Each heat pump provides space heating and domestic hot water to a single household. Besides a heat pump, each house has a buffer for domestic hot water and a floor heating system for space heating. The paper describes models and

  8. Central model predictive control of a group of domestic heat pumps, case study for a small district

    NARCIS (Netherlands)

    van Leeuwen, Richard Pieter; Fink, J.; Smit, Gerardus Johannes Maria; Helfert, Markus; Krempels, Karl-Heinz; Donnellan, Brian; Klein, Cornel

    2015-01-01

    In this paper we investigate optimal control of a group of heat pumps. Each heat pump provides space heating and domestic hot water to a single household. Besides a heat pump, each house has a buffer for domestic hot water and a floor heating system for space heating. The paper describes models and

  9. Electricity Market Optimization of Heat Pump Portfolio

    DEFF Research Database (Denmark)

    Biegel, Benjamin; Andersen, Palle; Pedersen, Tom S.

    2013-01-01

    We consider a portfolio of domestic heat pumps controlled by an aggregator. The aggregator is able to adjust the consumption of the heat pumps without affecting the comfort in the houses and uses this ability to shift the main consumption to hours with low electricity prices. Further, the aggrega......We consider a portfolio of domestic heat pumps controlled by an aggregator. The aggregator is able to adjust the consumption of the heat pumps without affecting the comfort in the houses and uses this ability to shift the main consumption to hours with low electricity prices. Further...

  10. Kajian Eksperimen Heat Exchahger Pada Heat Pump Menggunakan Refrijeran Hidrokarbon

    Directory of Open Access Journals (Sweden)

    Kusnandar

    2016-03-01

    Full Text Available Heat pump or usually known as pump energy is a device that can cooling and heating to be used, which functions as a cooling evaporator can be direct replace to heating as a function of the condenser using a reversing valve.. Using heat exchangers in the heat pump system is installed on the suction line and discharge line, so it will give the suction line temperature changes will be higher and discharge line temperatures will be lower, resulting in a greater cooling effect and lighter work of compression. The heat pump uses refrigerant type of hydrocarbon that is friendly to the environment, such as refrigerant R-290. From the results obtained research that the highest of Coefficient of Performance (COP in the heat pump using heat exchangers is 4.8 and without using heat exchanger is 4.1. So value of COP of haet pump between using heat exchanger and withaout heat exchanger is 0.7. The highest efficiency obtained on the heat pump using heat exchangers is 90.3%, and efficiency of heat pump without using heat exchanger is 78.95%.

  11. 开式湖水源热泵系统的水体热承载能力计算方法%CALCULATION MEETHOD OF THE HEAT CARRING CAPACITY OF WATER IN LAKE-WATER SOURCE HEAT PUMP SYSTEMS

    Institute of Scientific and Technical Information of China (English)

    王勇; 韩传璞

    2012-01-01

    在流体运动基本方程N-S方程的基础上,利用水温、质量和能量方程,建立了湖水源热泵系统利用水体水温变化的二维数学模型,并耦合求解得到水体水温的数值解.以夏季取水温度限值为依据,求解出在供冷期间不同负荷特征以及不同初始水温下水体能够承受的最大排热量.通过回归方法,得到水体热承载能力的检验方程.根据工程案例测试数据分析,该计算方法下的理论结果和实际测试结果较吻合,能够应用于湖水源热泵系统的可行性研究.%Based on N-S equations, dynamic two-dimensional model of lake water used for lake-water source heat pump system was built using temperature equation mass equation and energy equation. And arithmetic solution of wate temperature was attained by coupled solution. Based on limit temperature of water abstraction in summer, the largest quantity of heat the water can carried was obtained in different load and different start water temperature in heating period. Through regression, heat carrying capacity of water was obtained. Based on test data analysis, engineering project, theoretical result and test result in this computational method were coincide well,and this computational method can be used in feasibility study for lake-water source heat pump system.

  12. Earliest Deadline Control of a Group of Heat Pumps with a Single Energy Source

    NARCIS (Netherlands)

    Fink, J.; van Leeuwen, Richard Pieter

    2016-01-01

    In this paper, we develop and investigate the optimal control of a group of 104 heat pumps and a central Combined Heat and Power unit (CHP). The heat pumps supply space heating and domestic hot water to households. Each house has a buffer for domestic hot water and a floor heating system for space h

  13. Earliest Deadline Control of a Group of Heat Pumps with a Single Energy Source

    NARCIS (Netherlands)

    Fink, J.; van Leeuwen, Richard Pieter

    2016-01-01

    In this paper, we develop and investigate the optimal control of a group of 104 heat pumps and a central Combined Heat and Power unit (CHP). The heat pumps supply space heating and domestic hot water to households. Each house has a buffer for domestic hot water and a floor heating system for space

  14. A simplified heat pump model for use in solar plus heat pump system simulation studies

    DEFF Research Database (Denmark)

    Perers, Bengt; Andersen, Elsa; Nordman, Roger

    2012-01-01

    Solar plus heat pump systems are often very complex in design, with sometimes special heat pump arrangements and control. Therefore detailed heat pump models can give very slow system simulations and still not so accurate results compared to real heat pump performance in a system. The idea here...... is to start from a standard measured performance map of test points for a heat pump according to EN 14825 and then determine characteristic parameters for a simplified correlation based model of the heat pump. By plotting heat pump test data in different ways including power input and output form and not only...... as COP, a simplified relation could be seen. By using the same methodology as in the EN 12975 QDT part in the collector test standard it could be shown that a very simple model could describe the heat pump test data very accurately, by identifying 4 parameters in the correlation equation found....

  15. A simplified heat pump model for use in solar plus heat pump system simulation studies

    DEFF Research Database (Denmark)

    Perers, Bengt; Andersen, Elsa; Nordman, Roger

    2012-01-01

    Solar plus heat pump systems are often very complex in design, with sometimes special heat pump arrangements and control. Therefore detailed heat pump models can give very slow system simulations and still not so accurate results compared to real heat pump performance in a system. The idea here...... is to start from a standard measured performance map of test points for a heat pump according to EN 14825 and then determine characteristic parameters for a simplified correlation based model of the heat pump. By plotting heat pump test data in different ways including power input and output form and not only...... as COP, a simplified relation could be seen. By using the same methodology as in the EN 12975 QDT part in the collector test standard it could be shown that a very simple model could describe the heat pump test data very accurately, by identifying 4 parameters in the correlation equation found....

  16. Exergy Analysis of Carbon Dioxide Heat Pump Water Heater%二氧化碳热泵热水器的分析

    Institute of Scientific and Technical Information of China (English)

    朱开鼎; 陈海峰; 窦丹; 李九良

    2011-01-01

    In this paper,the operating principle of Carbon Dioxide Heat Pump Water Heater is explained;by constructing the exergy model and providing the initial conditions,an exergy analysis of working process of carbon dioxide heat pump water heater is made;which results in the ratio of exergy consumption from different part of the heater,and indicates the method of improving the ratio of utilizing the exergy.%介绍了二氧化碳热泵热水器的工作原理,通过建立模型,给出初始条件,对二氧化碳热泵热水器的工作过程进行了分析,得出了各部分所占的消耗比重,指出了提高利用率的方法。

  17. Optimized ground coupled heat pump design: Phase 1, Final report

    Energy Technology Data Exchange (ETDEWEB)

    Andrews, J.W.; Catan, M.; Le Doux, P.; Metz, P.D.; Saunders, J.H.

    1985-10-01

    This report describes the first phase of a project to design a water-to-air heat pump optimized for ground coupling applications. The project is being conducted jointly by Brookhaven National Laboratory (BNL), Oak Ridge National Laboratory (ORNL), and an industrial partner to be selected via a competitive procurement. In the completion of Phase I, three major tasks were completed. First, based on experimental work performed at BNL, water-refrigerant heat exchanger models were developed for incorporation into the ORNL heat pump optimization program. Next, a procedure was developed to generate correlations between heat pump entering fluid temperature and load. The correlations, called ''Source Temperature/Load Maps'', will tell the optimization program how many hours/season the heat pump will operate with any pair of values for these quantities. This report discusses these first two tasks within Phase I.

  18. A ground water source heat pump for the air-conditioning of a supermarket; Une PAC sur nappe phreatique pour climatiser un hypermarche

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    2002-04-01

    A thermodynamical solution involving a ground water source heat pump and 19 roof top air-conditioners has been retained for the air-conditioning of a 41000 m{sup 2} supermarket of Colmar (Alsace, France). The supermarket is also equipped with a computer-monitored refrigeration system for the food products and a centralized technical management for the optimization of the installation operation. (J.S.)

  19. News from heat-pump research - Large-scale heat pumps, components, heat pumps and solar heating; News aus der Waermepumpen-Forschung - Gross-Waermepumpen, Komponenten, Waermepumpe und Solar

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2010-06-15

    These proceedings summarise the presentations made at the 16{sup th} annual meeting held by the Swiss Federal Office of Energy's Heat Pump Research Program in Burgdorf, Switzerland. The proceedings include contributions on large-scale heat pumps, components and the activities of the heat pump promotion society. A summary of targets and trends in energy research in general is presented and an overview of the heat pump market in 2009 and future perspectives is given. International work within the framework of the International Energy Agency's heat pump group is reviewed, including solar - heat pump combinations. Field-monitoring and the analysis of large-scale heat pumps are discussed and the importance of the use of correct concepts in such installations is stressed. Large-scale heat pumps with carbon dioxide as working fluid are looked at, as are output-regulated air/water heat pumps. Efficient system solutions with heat pumps used both to heat and to cool are discussed. Deep geothermal probes and the potential offered by geothermal probes using carbon dioxide as a working fluid are discussed. The proceedings are rounded off with a list of useful addresses.

  20. 吸收式热泵回收300MW机组循环水余热的设计研究%Design and Research of Absorption Type Heat Pump Recycling 300MW Unit Circulating Water Waste Heat

    Institute of Scientific and Technical Information of China (English)

    马光耀

    2015-01-01

    Low temperature waste heat of 300MW unit circulating water in a plant was recycled through the ab-sorption heatpump,circulating water of different temperature has great influence on the design scheme of heat pump.In this design, the temperature difference of heat pump import for the circulating wateris 7℃,the heatpump circulating water inlet temperature is 31~35℃,heating extraction steam pressure is about 0.3MPa,steam consump-tion for the steam driving is 270t/h,The temperature of hot topwater after heating by heat pump increases from 43℃ to 74℃,heat recovery capacity of the heat pumpis 131tMo,the whole heating capacity of the heat pump is about 318MW.%对某厂300MW机组循环水的低温余热通过吸收式热泵进行回收,不同的循环水温度对热泵的设计方案有着很大的影响.该设计中循环水进出热泵温差为7℃,热泵进口处循环水温度为31~35℃,采暖抽汽压力约为0.3MPa,驱动蒸汽用汽量为270t/h,热网水经热泵加热后温度从43℃升至74℃,热泵余热回收量为131MW,热泵总的制热量约为318MW.

  1. Exergy analysis of the performance of low-temperature district heating system with geothermal heat pump

    Directory of Open Access Journals (Sweden)

    Sekret Robert

    2014-03-01

    Full Text Available Exergy analysis of low temperature geothermal heat plant with compressor and absorption heat pump was carried out. In these two concepts heat pumps are using geothermal water at 19.5 oC with spontaneous outflow 24 m3/h as a heat source. The research compares exergy efficiency and exergy destruction of considered systems and its components as well. For the purpose of analysis, the heating system was divided into five components: geothermal heat exchanger, heat pump, heat distribution, heat exchanger and electricity production and transportation. For considered systems the primary exergy consumption from renewable and non-renewable sources was estimated. The analysis was carried out for heat network temperature at 50/40 oC, and the quality regulation was assumed. The results of exergy analysis of the system with electrical and absorption heat pump show that exergy destruction during the whole heating season is lower for the system with electrical heat pump. The exergy efficiencies of total system are 12.8% and 11.2% for the system with electrical heat pump and absorption heat pump, respectively.

  2. 重庆地区地表水地源热泵系统冬季供暖工程应用%Engineering application of surface water source heat pump for winter heating in Chongqing area

    Institute of Scientific and Technical Information of China (English)

    卢军; 黄俊杰; 廖兴中

    2013-01-01

    Tests the heating operating conditions of five surface water source heat pump projects in Chongqing area,and compares them with those of the air source heat pump and boiler heating mode.The results show that the heating coefficient of performance (COP) of the river water source heat pump unit reaches 2.8 to 5.3 and the heating energy efficiency ratio (EER) reaches 2.7 to 4.3,and the COP and EER of the lake water source heat pump system reach 4.4 and 3.0 respectively; the indoor temperature and relative humidity can be maintained about 20℃ and above 40% respectively; the improving rates in energy efficiency of a surface water source heat pump system for winter heating are respectively 8.0% to 72.0%and 18.0% to 87.9% compared with the air source heat pump and boiler heating,and energy saving is significant.%以重庆地区5个地表水地源热泵项目为例,对其冬季供暖运行工况进行了实测,并与空气源热泵和锅炉供暖进行了比较.结果表明,江水源热泵系统的机组制热性能系数COP和系统制热能效比EER分别能达到2.8~5.3和2.7~4.3,湖水源热泵系统的COP和EER分别能达到4.4和3.0,并且室内温度和相对湿度分别能保持在20℃左右和40%以上;相比于空气源热泵和锅炉供暖,地表水地源热泵系统冬季供暖的能效提高率分别达到了8.0%~72.0%和18.0%~87.9%,节能显著.

  3. Nonlinear Aspects of Heat Pump Utilization

    Directory of Open Access Journals (Sweden)

    R. Najman

    2010-01-01

    Full Text Available This work attempts to answer the question: How much can we believe that the coefficient of performance provided by the manufacturer is correct, when a heat pump is required to face the real load coming from changes of temperature? The paper summarizes some basics of heat pump theory and describes the results of numerical models.

  4. Unitary air-to-air heat pumps

    Energy Technology Data Exchange (ETDEWEB)

    Christian, J.E.

    1977-07-01

    This technology evaluation covers commercially available unitary heat pumps ranging from nominal capacities of 1/sup 1///sub 2/ to 45 tons. The nominal COP of the heat pump models, selected as representative, vary from 2.4 to 2.9. Seasonal COPs for heat pump installations and single-family dwellings are reported to vary from 2.5 to 1.1, depending on climate. For cooling performance, the nominal EER's vary from 6.5 to 8.7. Representative part-load performance curves along with cost estimating and reliability data are provided to aid: (1) the systems design engineer to select suitably sized heat pumps based on life-cycle cost analyses, and (2) the computer programmer to develop a simulation code for heat pumps operating in an Integrated Community Energy System.

  5. Energy performance and consumption for biogas heat pump air conditioner

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Zhenjun [Architectural Engineering College, Qingdao Agricultural University, 266109 (China); Qingdao Institute of Bioenergy and Bioprocess Technology, Chinese Academy of Sciences, Qingdao 266101 (China); Tianjin University, Tianjin, 300072 (China); Wu, Huaizhi; Wu, Meiling [Qingdao Institute of Bioenergy and Bioprocess Technology, Chinese Academy of Sciences, Qingdao 266101 (China); Tianjin University, Tianjin, 300072 (China)

    2010-12-15

    Biogas engine-driven heat pump air conditioner is a new-style system which includes biogas engine-driven heat pump, primary heat exchanger, second heat exchanger, sprayed room and fans, pumps, etc. In summertime, the air can be reheated by the waste heat water from the biogas engine in the system, while the air can be reheated and humidified by the waste heat water in winter. Reducing or displacing electrical heating requirements can achieve the great opportunity for significant energy savings. This paper, therefore, aims to improve the energy performance of the AC system by using the waste heat from the biogas engine. The mathematic model was used to research the BHPAC. Explicitly, we investigated the influence of various factors including the outdoor air temperature and humidity in summer and winter. Results show that the biogas engine-driven heat pump air conditioner can save more energy than the electrical power heat pump. In summer, the minimum for percentage of primary energy saving for BHPAC is over 25%. With the outdoor air dry-bulb temperature and the relative humidity rises, the saving energy percentage rises. In winter, the minimum for percentage of primary energy saving for BHPAC is 37%. The more the outdoor air relative humidity of the outdoor air decreases, the more the BHPAC saves energy. It is proved that the system which is a highly actively fully utilizing energy technology has good partial load characteristic and good effects of energy saving. (author)

  6. Low-Cost Gas Heat Pump for Building Space Heating

    Energy Technology Data Exchange (ETDEWEB)

    Garrabrant, Michael [Stone Mountain Technologies, Inc., Johnson City, TN (United States); Keinath, Christopher [Stone Mountain Technologies, Inc., Johnson City, TN (United States)

    2016-10-11

    , which will allow for improved load matching. In addition, the energy savings analysis showed that a house in Albany, NY, Chicago, IL and Minneapolis, MN would save roughly 32, 28.5 and 36.5 MBtu annually when compared to a 100% efficient boiler, respectively. The gas absorption heat pump achieves this performance by using high grade heat from the combustion of natural gas in combination with low grade heat extracted from the ambient to produce medium grade heat suitable for space and water heating. Expected product features include conventional outdoor installation practices, 4:1 modulation, and reasonable economic payback. These factors position the technology to gain significant market penetration, resulting in a large reduction of energy use and greenhouse gas emissions for residential space heating.

  7. Duplex Stirling gas fired heating only heat pump

    Science.gov (United States)

    Beale, W.

    1982-03-01

    In phase I the Duplex Stirling Gas fired Heat Pump was analyzed with the aid of the Sunpower third order simulation and optimization code and found to show heating COP of 1.7 at the rating point of 8 C (17 F) with a heat delivery of 10 kW. Also it was found that a direct heat exchange between working fluid and source and sink air was consistent with high COP in the heat pump, thus eliminating the need for an intermediate heat transfer fluid and its associated pumps and controls. Further, it was demonstrated in the simulation that the heat engine power output could be matched to the heat pump load over the range of source temperatures without need of complex control systems. Cost estimates, along with COP figures from the analysis indicated a payback time of 2 to 4 years in completion with existing combustion heating systems in northern climates.

  8. Analysis of using air-source heat pump water chiller-heater units in the cold regions%空气源热泵冷热水机组在寒冷地区应用的分析

    Institute of Scientific and Technical Information of China (English)

    马最良; 杨自强; 姚杨; 喻银平

    2001-01-01

    针对空气源热泵冷热水机组在寒冷地区冬季使用时结霜、热效率低等问题,提出一种双级热泵系统,即由空气源热泵冷热水机组提供10~20 ℃温水,作为水源热泵的低位热源,组成水源热泵供热系统。分析了这种系统的技术经济性,认为该系统是可行的,具有节能和环保意义。%imed at solving frosting and low heating efficiency of heat pumps in cold regions, puts forward a twin heat pumps heating system that consists of an air source heat pump and a water source heat pump. The air source heat pump supplies 10-20 ℃ water as low grade heat source of the water source heat pump. Analyses the technical and economical features of the system. Considers that the system is practicable and has energy conservation and environment protection effects.

  9. Jet pump assisted arterial heat pipe

    Science.gov (United States)

    Bienert, W. B.; Ducao, A. S.; Trimmer, D. S.

    1978-01-01

    This paper discusses the concept of an arterial heat pipe with a capillary driven jet pump. The jet pump generates a suction which pumps vapor and noncondensible gas from the artery. The suction also forces liquid into the artery and maintains it in a primed condition. A theoretical model was developed which predicts the existence of two stable ranges. Up to a certain tilt the artery will prime by itself once a heat load is applied to the heat pipe. At higher tilts, the jet pump can maintain the artery in a primed condition but self-priming is not possible. A prototype heat pipe was tested which self-primed up to a tilt of 1.9 cm, with a heat load of 500 watts. The heat pipe continued to prime reliably when operated as a VCHP, i.e., after a large amount of noncondensible gas was introduced.

  10. Exploring heating performance of gas engine heat pump with heat recovery

    Institute of Scientific and Technical Information of China (English)

    董付江; 刘凤国; 李先庭; 尤学一; 赵冬芳

    2016-01-01

    In order to evaluate the heating performance of gas engine heat pump (GEHP) for air-conditioning and hot water supply, a test facility was developed and experiments were performed over a wide range of engine speed (1400−2600 r/min), ambient air temperature (2.4−17.8 °C) and condenser water inlet temperature (30−50 °C). The results show that as engine speed increases from 1400 r/min to 2600 r/min, the total heating capacity and energy consumption increase by about 30% and 89%, respectively; while the heat pump coefficient of performance (COP) and system primary energy ratio (PER) decrease by 44% and 31%, respectively. With the increase of ambient air temperature from 2.4 °C to 17.8 °C, the heat pump COP and system PER increase by 32% and 19%, respectively. Moreover, the heat pump COP and system PER decrease by 27% and 15%, respectively, when the condenser water inlet temperature changes from 30 °C to 50 °C. So, it is obvious that the effect of engine speed on the performance is more significant than the effects of ambient air temperature and condenser water inlet temperature.

  11. Flue gas condensing with heat pump; Roekgaskondensering med vaermepump

    Energy Technology Data Exchange (ETDEWEB)

    Axby, Fredrik; Pettersson, Camilla [Carl Bro Energikonsult AB, Malmoe (Sweden)

    2004-11-01

    Flue gas condensing is often both a technically and economically efficient method to increase the thermal efficiency in a plant using fuels with high moisture and/or high hydrogen content. The temperature of the return water in district heating systems in Sweden is normally 50 deg C, which gives quite high efficiency for a flue gas condenser. The flue gas after the flue gas condenser still contains energy that to some extent can be recovered by a combustion air humidifier or a heat pump. The object of this project is to technically and economically analyse flue gas condensing with heat pump. The aim is that plant owners get basic data to evaluate if a coupling between a flue gas condenser and a heat pump could be of interest for their plant. With a heat pump the district heating water can be 'sub cooled' to increase the heat recover in the flue gas condenser and thereby increase the total efficiency. The project is set up as a case study of three different plants that represent different types of technologies and sizes; Aabyverket in Oerebro, Amagerforbraending in Copenhagen and Staffanstorp district heating central. In this report a system with a partial flow through the condenser of the heat pump is studied. For each plant one case with the smallest heat pump and a total optimization regarding total efficiency and cost for investment has been calculated. In addition to the optimizations sensitivity analyzes has been done of the following parameters: Moisture in fuel; Type of heat pump; Temperature of the return water in the district heating system; and, Size of plant. The calculations shows that the total efficiency increases with about 6 % by the installation of the heat pump at a temperature of the return water in the district heating system of 50 deg C at Aabyverket. The cost for production of heat is just below 210 kr/MWh and the straight time for pay-off is 5,4 years at 250 kr/MWh in heat credit and at 300 kr/MWh in basic price for electricity. The

  12. First experience gained with heat-pump utilization in animal-husbandry plants

    Energy Technology Data Exchange (ETDEWEB)

    Kuemmritz, W.; Schaeffel, W.

    1982-10-01

    For cleaning and desinfection of all milk-conducting plant parts, the LPG Tierproduktion at the town of Berlstedt (capacity of 2000 animal stands) needs a daily amount of c. 60 cbm of heated water. Recently 50% of this useful-water requirement has been covered by four small-size heat pumps WW 12 of a water/water configuration. In the heating house, two heat pumps have been installed on top of each other in each case. The circuit plan of the heat-pump facility is demonstrated. The facility operates at open and closed loop, contains two-step rotary pumps and heats useful water to 50-60/sup 0/C. Two heat pumps are operated via shift water throughout the year, the remaining two use brook water in summer and well water in winter as their heat source. 40 t of fuel oil were saved in 1981.

  13. 二氧化碳家用热泵热水器试验研究%Experimental study on CO2 house-hold heat pump water heater

    Institute of Scientific and Technical Information of China (English)

    李廷勋; 王冬; 钟家淞; 黄逊青

    2013-01-01

    CO2 is one of the research focuses in the refrigeration field due to its environmental protection and unique thermodynamic properties. The hermetical CO2 compressor for house-hold appliance is a big challenge because of its high pressure. In order to verify the superiority of CO2 application in the heat pump water heater and test the operation law of the system, a new CO2 heat pump water heater prototype with hermetical compressor developed in China was tested. Keeping the inlet water 15-50 ℃ and the outlet hot water 65-90 ℃ ,the key characters such as the heating capacity, COP and the exhaust temperature with different evaporating temperature, inlet and outlet water temperature, and exhaust pressure were measured. The results show that the CO2 heat pump water heater can steadily provide hot water above 90℃, having obvious advantages in heating at high temperature. The system can still run smoothly when the evaporation temperature is - 20 ℃, showing better advantages in heating at low temperature.%CO2因为环保及独特的热力学优势,一直是制冷空调领域的研究热点,然而由于其工作压力较高,用于家用热泵热水器的全封闭式CO2压缩机开发较困难.为了验证CO2在热泵热水器上应用的优势以及研究其系统的运行规律,以国产全封闭式CO2压缩机为基础,设计并搭建了空气源CO2热泵热水器测试系统,在进水温度15-50℃,出水温度65-90℃范围内,测试了不同进、出水温度、不同蒸发温度以及不同排气压力条件下,热泵系统的制热量、COP以及排气温度等关键特征,发现CO2能够稳定提供90℃以上热水,在高温制热上优势明显.同时,即使在蒸发温度为-20℃,系统仍然能够平稳运行,表现出较好的低温运行优势.

  14. 直热式热泵热水器冷凝器结构优化试验研究%Experimental Research on Structure Optimization of Condenser of Directly-heated Type Heat-pump Water Heater

    Institute of Scientific and Technical Information of China (English)

    毛瑞萍

    2015-01-01

    搭建了空气源热泵热水器试验台。在标准工况下,分别比较了普通套管式冷凝器,3套管式冷凝器和板式冷凝器对热泵系统运行性能的影响。结果表明,板式换热器在热泵热水器系统中换热性能大大优于另外两种常规换热器,其性能系数达到4.1,比使用其他两种冷凝器性能系数提高20%左右。试验结果为如何提高热泵热水器性能提供了依据。%The air source heat pump water heater test rig was set up. Under the standard operating conditions, the influence of the ordinary casing type condenser, the 3 tube condenser and the plate condenser on the operating perfor-mance of the heat pump system are compared. The results show that the plate heat exchanger in heat pump water heater system in heat transfer performance is much better than other two conventional heat exchangers. Its coefficient of per-formance reached 4.1, which higher than the performance coefficient of other two condensers increased by about 20%. The experimental results provided the basis for improving the performance of the heat pump water heater.

  15. Advanced heat pump research and development

    Science.gov (United States)

    Kuliasha, M. A.

    The Office of Building Energy Research and Development of the U.S. Department of Energy (DOE), has been funding R&D in advanced heat pumps and appliances since 1976. Much of that research has been managed for DOE by the Oak Ridge National Laboratory (ORNL). The objective of the Building Equipment Research (BER) program at ORNL has been to generate new concepts and develop a technology base for improving the energy efficiency and load characteristics of energy conversion equipment used in residential and commercial buildings. The research being pursued to achieve these objectives falls under three general areas: thermally activated heat pumps (TAHP), refrigeration systems, and building equipment systems. The TAHP work is concentrated on three technologies: (1) absorption heat pumps; (2) Stirling engine-driven heat pumps; and (3) internal combustion (IC) engine-driven heat pumps. Major project areas in refrigeration systems research include electric heat pumps, ground-coupled heat pumps, and refigerant mixtures. In the building equipment systems areas, project areas include advanced distribution systems, advanced insulation for appliances, and commercial building equipment.

  16. Transient Analysis of a Magnetic Heat Pump

    Science.gov (United States)

    Schroeder, E. A.

    1985-01-01

    An experimental heat pump that uses a rare earth element as the refrigerant is modeled using NASTRAN. The refrigerant is a ferromagnetic metal whose temperature rises when a magnetic field is applied and falls when the magnetic field is removed. The heat pump is used as a refrigerator to remove heat from a reservoir and discharge it through a heat exchanger. In the NASTRAN model the components modeled are represented by one-dimensional ROD elements. Heat flow in the solids and fluid are analyzed. The problem is mildly nonlinear since the heat capacity of the refrigerant is temperature-dependent. One simulation run consists of a series of transient analyses, each representing one stroke of the heat pump. An auxiliary program was written that uses the results of one NASTRAN analysis to generate data for the next NASTRAN analysis.

  17. 云驾岭煤矿双水源热泵系统设计%Double water-source heat pump system designing for Yunjialing colliery

    Institute of Scientific and Technical Information of China (English)

    张昌建; 王景刚; 梁界武; 袁常升

    2012-01-01

    The heat pump system adopts the cooling water from power plant and the drainage from coal mine as double water source, of which the temperature varies from 7 to 50 "C . By optimally matching the high and low temperature heat pump units, the system can output 70 to 80 °C high-temperature hot water, 40 to 55 °C mid-temperature hot water and 7 to 12 °C air conditioning chilled water at the same time, and recycle the waste water from the cooling water and the drainage for heating, air conditioning,, providing domestic hot water for industrial site buildings and preventing freeze in the pit shaft.%该热泵系统以云驾岭煤矿电厂冷却水、矿井排水作为双水源,热源温度变化范围在7~50℃之间;采用高温热泵机组和低温热泵机组优化匹配,可以同时输出70~80℃高温热水和40~55℃中温热水及7~12℃空调冷水,回收电厂冷却水和矿井排水中的废热用于云驾岭煤矿工业区建筑供暖、空调和制取生活热水及井筒防冻.

  18. Heating and cooling with ground-loop heat pumps; Heizen und Kuehlen mit erdgekoppelten Waermepumpen

    Energy Technology Data Exchange (ETDEWEB)

    Afjei, Th.; Dott, R. [Institut Energie am Bau, Fachhochschule Nordwestschweiz (FHNW), Muttenz (Switzerland); Huber, A. [Huber Energietechnik AG, Zuerich (Switzerland)

    2007-08-15

    This final report for the Swiss Federal Office of Energy (SFOE) presents the results of the SFOE-project 'Heating and cooling with ground coupled heat pumps' in which the benefits and costs of a heat pump heating and cooling system with a borehole heat exchanger were examined. In particular the dimensioning of the hydraulic system, control concept and user behaviour are dealt with. The results of the simulations of thermal building behaviour with MATLAB/SIMULINK, CARNOT, and EWS are discussed. The results of parameter studies carried out, including varying shading, cooling characteristic curves, temperature differences in the heat exchanger and the dead time between heating and cooling mode are discussed. These showed that a simple system with heat pump and borehole heat exchanger for heating or preparation of domestic hot water as well as for passive cooling proved to be the best choice.

  19. An open cycle absorption heat pump

    Energy Technology Data Exchange (ETDEWEB)

    Lazzarin, R.M.; Longo, G.A. (Padua Univ. (Italy)); Piccininni, F. (Politecnico di Bari (Italy). Ist. di Fisica Tecnica)

    1992-09-01

    By using absorption dehumidification it is possible to obtain an open cycle absorption heat pump fed by a natural gas burner. The machine couples great simplicity with very good thermodynamic performance. The main feature is the recovery of the latent heat of the air flow. The open cycle heat pump is applied here to building heating, internal temperature 20[sup o]C, relative humidity 50%, with forced ventilation. The system has essentially a packed tower bed for dehumidification, a regenerator fed by a natural gas burner, connected to a condenser, and some heat exchangers. (author).

  20. Solar Assisted Heat Pump Study for Heating of Military Facilities.

    Science.gov (United States)

    1978-07-01

    This study identified 21 generic solar assisted heat pump systems and subjectively evaluated them. The six most promising systems were evaluated in... heat pump . Preliminary drawings intergrating this system into a family housing unit at Little Rock AFB were developed. The system selected had a 27-32 year pay back. (Author)

  1. Linear programming control of a group of heat pumps

    NARCIS (Netherlands)

    Fink, J.; van Leeuwen, Richard Pieter; Hurink, Johann L.; Smit, Gerardus Johannes Maria

    2015-01-01

    For a new district in the Dutch city Meppel, a hybrid energy concept is developed based on bio-gas co-generation. The generated electricity is used to power domestic heat pumps which supply thermal energy for domestic hot water and space heating demand of households. In this paper, we investigate di

  2. 热泵技术在油田生产污水余热回收中的应用%Application of heat pump in waste heat recovery for waste water of oilfield production

    Institute of Scientific and Technical Information of China (English)

    张水生; 袁长军

    2015-01-01

    Heat pump is used for waste heat recovery,which can solve the issues of recovering waste heat in high temperature waste water in oil production.%针对油田生产污水水量多,温度较高,余热资源丰富却没有回收利用的现状,应用热泵技术进行生产污水余热回收,降低能源消耗,并对现场应用效果进行分析.

  3. Heat pumps in combined heat and power systems

    DEFF Research Database (Denmark)

    Ommen, Torben Schmidt; Markussen, Wiebke Brix; Elmegaard, Brian

    2014-01-01

    of the considered cases. When considering a case where the heat pump is located at a CHP (combined heat and power) plant, a configuration that increases the DH return temperature proposes the lowest operation cost, as low as 12 EUR MWh-1 for a 90 °C e 40 °C DH network. Considering the volumetric heating capacity......Heat pumps have previously been proposed as a way to integrate higher amounts of renewable energy in DH (district heating) networks by integrating, e.g., wind power. The paper identifies and compares five generic configurations of heat pumps in DH systems. The operational performance......, a third configuration is superior in all cases. Finally, the three most promising heat pump configurations are integrated in a modified PQ-diagram of the CHP plant. Each show individual advantages, and for two, also disadvantages in order to achieve flexible operation....

  4. 溴化锂吸收式热泵回收循环水余热的模拟研究%Using lithium bromide absorption heat pump to recycle circulating water heat:a simulation

    Institute of Scientific and Technical Information of China (English)

    车德勇; 吕婧; 高龙; 李少华; 白章

    2014-01-01

    循环水的余热造成环境热污染,同时也损失了大量的热能。对此,利用吸收式热泵对其进行回收利用。以某200 MW抽凝机组及其供热系统为例,采用Aspen Plus软件建立单、双效溴化锂吸收式热泵模型,并进行变工况模拟对比分析。研究结果表明:当热泵出口热网水温度升高或热泵驱动汽源汽量增加时,单、双效循环热泵热力系数均降低;在相同热泵出口热网水温度下,双效循环比单效循环节省蒸汽率约30%;当采用多效循环且热泵出口热网水温度高于90℃时,可采用热泵先将热网回水加热到90℃左右,然后采用尖峰加热器加热热网水到需要的温度,以保证系统稳定运行。%Waste heat of circulating water emitted to the environment causes huge thermal pollution and los-ses lots of thermal energy.Thus,absorption heat pump is applied to recycle the heat.Taking a certain 200 MW extraction condensing unit and its heating system as the example,the Aspen Plus software was employed to establish the single/double effect lithium bromide absorption heat pump model.Moreover, comparative analysis for the system under variable conditions was performed.The results indicate that, with an increase in the heat pump outlet heating network water temperature or the heat pump driven steam source,the coefficient of performance (COP)of both the single and double effect cycle heat pump declined. For the same heating temperature,the double-effect cycle can save steam by about 30% more than the sin-gle-effect cycle.When the temperature of heat pump outlet heating network water exceeded 90 ℃,the heat-ing network return water can be heated to about 90 ℃ by heat pump first,and then to the required temper-ature by spike heater,thus to ensure the stable operation of system.

  5. Developing a Magnetocaloric Domestic Heat Pump

    DEFF Research Database (Denmark)

    Bahl, Christian R.H.

    2014-01-01

    beverage coolers, A/Cs for cars and electronics cooling. Devices for heating have not been extensively demonstrated. Here we consider a promising application of magnetocaloric heat pumps for domestic heating. The task of designing and building such a device is a multidisciplinary one encompassing materials...

  6. Technology Solutions Case Study: Air-To-Water Heat Pumps with Radiant Delivery in Low Load Homes, Tucson, Arizona and Chico, California

    Energy Technology Data Exchange (ETDEWEB)

    None

    2013-11-01

    Space conditioning represents nearly 50% of average residential household energy consumption, highlighting the need to identify alternative cost-effective, energy-efficient cooling and heating strategies. As homes are better built, there is an increasing need for strategies that are particularly well suited for high performance, low load homes. ARBI researchers worked with two test homes in hot-dry climates to evaluate the in-situ performance of air-to-water heat pump (AWHP) systems, an energy efficient space conditioning solution designed to cost-effectively provide comfort in homes with efficient, safe, and durable operation. Both systems were fully instrumented and have been monitored over one year to capture complete performance data over the cooling and heating seasons. Results are used to quantify energy savings, cost-effectiveness, and system performance using different operating modes and strategies. This strategy is most effective in tight, insulated homes with high levels of thermal mass (i.e. exposed slab floors).

  7. Thermoeconomic comparison of industrial heat pumps

    DEFF Research Database (Denmark)

    Ommen, Torben Schmidt; Markussen, Christen Malte; Reinholdt, L.

    2011-01-01

    Four natural working fluids in various heat pump cycles are expected to cover the heating range between 50oC and 150°C. The different thermodynamic cycles are the Condensing Vapour, Transcritical and Compression/Absorption. As the considered technologies have significant differences in application......, limitations and design, a generic comparison is used. To establish the optimal individual temperature range of operation, a thermoeconomic evaluation is performed, with heat price as the decision parameter. Each individual heat pump is favourable in specific temperature intervals, which will vary according...... to the temperature lift between sink and source. At temperature lifts below 30°C the entire temperature range is covered. Exceeding this temperature lift, the range of sink temperatures is not completely covered above 125°C. Three of the heat pumps prove very cost competitive when compared to heating with natural...

  8. Thermoeconomic comparison of industrial heat pumps

    DEFF Research Database (Denmark)

    Ommen, Torben Schmidt; Markussen, Christen Malte; Reinholdt, L.

    2011-01-01

    Four natural working fluids in various heat pump cycles are expected to cover the heating range between 50oC and 150°C. The different thermodynamic cycles are the Condensing Vapour, Transcritical and Compression/Absorption. As the considered technologies have significant differences in application......, limitations and design, a generic comparison is used. To establish the optimal individual temperature range of operation, a thermoeconomic evaluation is performed, with heat price as the decision parameter. Each individual heat pump is favourable in specific temperature intervals, which will vary according...... to the temperature lift between sink and source. At temperature lifts below 30°C the entire temperature range is covered. Exceeding this temperature lift, the range of sink temperatures is not completely covered above 125°C. Three of the heat pumps prove very cost competitive when compared to heating with natural...

  9. Study on Recharge Ability of Ground Water Heat Pump System%地下水源热泵系统中回灌能力分析

    Institute of Scientific and Technical Information of China (English)

    赵宏亮

    2012-01-01

    近年,地下水源热泵技术在我国被广泛应用,并在节能、环保等方面取得了一定效益.但是,回灌问题仍是困扰我国地下水源热泵发展的瓶颈.以唐山市丰润区乡居假日住宅区A4区地下水源热泵系统的应用为例,从区域水文地质条件方面,对水源热泵系统中地下水回灌能力进行了分析,指出开展地下水源热泵项目时,掌握热源井所在区域水文地质条件的重要性.探讨了影响地下水回灌能力的关键因素,其中包括区域水文地质条件、热源井成井工艺、回灌井阻塞以及地下水回灌方式.%In recent years, ground water beat pump technology has been widely applied in China and has made certain benefits in energy saving and environmental protection. However, groundwater recharge is still the main difficulty. This paper studied on the recharge of ground water heat pump according to the local hydrogeologic conditions at A4 area in the Fengrun countryside holiday block in Tangshan City, pointed out that the local hydrogeological condition is very important, and discussed the key factors impacting the recharge ability of ground water heat pump, including local hydrogeologic conditions,heat source well completion technology, clogging problem of disposal well and groundwater recharge mode.

  10. ENERGY STAR Certified Geothermal Heat Pumps

    Data.gov (United States)

    U.S. Environmental Protection Agency — Certified models meet all ENERGY STAR requirements as listed in the Version 3.0 ENERGY STAR Program Requirements for Geothermal Heat Pumps that are effective as of...

  11. High performance heat pump absorption cycles

    Energy Technology Data Exchange (ETDEWEB)

    Lazzarin, R.; Longo, G.; Rossetto, L.

    1988-10-01

    Absorption heat pumps can provide high performances when operating in suitable cycles with multiple effects. This report describes some multistage cycles and evaluates the coefficient of performance realistically obtainable both in winter and summer working conditions.

  12. Hot Topics! Heat Pumps and Geothermal Energy

    Science.gov (United States)

    Roman, Harry T.

    2009-01-01

    The recent rapid rises in the cost of energy has significantly increased interest in alternative energy sources. The author discusses the underlying principles of heat pumps and geothermal energy. Related activities for technology education students are included.

  13. Hot Topics! Heat Pumps and Geothermal Energy

    Science.gov (United States)

    Roman, Harry T.

    2009-01-01

    The recent rapid rises in the cost of energy has significantly increased interest in alternative energy sources. The author discusses the underlying principles of heat pumps and geothermal energy. Related activities for technology education students are included.

  14. CO2热泵热水器的实验室评估%Laboratory Assessment of CO2 Heat Pump Water Heater

    Institute of Scientific and Technical Information of China (English)

    周子成

    2015-01-01

    本文叙述一台带有室外热交换器的变速CO2热泵热水器的实验室测定结果。测试包括在室外环境温度为-8.3℃至35℃下进行的标准24小时和第1小时的额定等级试验的热泵效率;室外机的噪声水平测定;和对输送水量测定以及室外机组在10℃环境条件下运行时的高效率淋浴水量测定。%This paper describes the results of a CO 2 Heat pump water heaters test with an outdoor heat exchang-er.The project conducted lab tests of a variable -speed, CO2 refrigerant HPWH with the heat exchanger located in the outdoor unit.The testing plan included observing heat pump efficiency at a range of outdoor ambient temperatures from -8.3℃to 35℃; conducting the standard 24-hour and 1-hour rating tests; measuring outdoor unit noise levels; and quantifying the number of efficient showers delivered with the outdoor unit operating at 10℃ ambient conditions.

  15. Recycling Waste Heat of Circulating Water Using Absorption Heat Pump in Thermal Power Plant%利用吸收式热泵回收热电厂循环水余热

    Institute of Scientific and Technical Information of China (English)

    石会群; 高立江

    2013-01-01

    Recycle the waste heat of circulating water in heating power to heat water by using type I absorption heat pump. In this paper, it introduces the original design parameters, the system scheme and the selection of units. In addition, it introduces the energy efficiency, environmental benefits and the question of the project. Through the presentation of the use of heat pump technology for recovery of waste heat from power plant, the technology is feasible, reliable, and is worthy of popularizing in northern heating power plant.%利用第一类吸收式热泵技术回收供热电厂冷却循环水余热用于城市供热,本文从设计的原始参数、系统方案和机组选型等进行介绍,并介绍了项目达到的节能效益、环保效益,以及方案存在的问题,通过说明利用热泵技术回收电厂余热技术是可行、可靠的,在北方供热电厂值得大力推广。

  16. Commercial absorption heat pumps (design, performance)

    Energy Technology Data Exchange (ETDEWEB)

    Lazzarin, R. (Padua Univ. (Italy). Ist. di Fisica Tecnica)

    1986-04-01

    After a historical review of the development of absorption heat pumps, a critical analysis is presented of the design and operation of typical 25-40 kW, commercially available heat pumps. This engineering critique is followed by an analysis of the performance of 25 kW plant thoroughly tested to provide, by means of statistically significant data, a reliable assessment of the coefficient of performance and capacity in function of the cold source temperature for different return temperatures.

  17. Economics of heat pump assisted drying systems

    Energy Technology Data Exchange (ETDEWEB)

    Pendyala, V.R.; Devotta, S.; Patwardhan, V.S.

    1986-01-01

    The sensitivity of the economics of heat pump assisted dryers to various factors such as design, operational and economic variables, when payback period is adopted as the criterion, has been assessed for Indian conditions. Results have been presented in graphical form to illustrate the optimum conditions for economic viability. For the specific typical conditions and the current costs of electricity and steam in India, a heat pump assisted dryer has a payback period in the range of two to three years.

  18. Optimized ground coupled heat pump mechanical package

    Energy Technology Data Exchange (ETDEWEB)

    Catan, M.A.

    1984-01-01

    The system which was optimized was a horizontal earth coil in a given house in the Pittsburgh area. The types of components used in the heat pump are essentially conventional. The method of this study is derived from one used to optimize an air-source heat pump for operation at standard steady state conditions. A computer model, created at Oak Ridge National Laboratory (ORNL), is used to predict heat pump performance for specified configuration and operating conditions. A predetermined set of design parameters is automatically altered by a constrained minimization program (a Numerical Algorithms Group library routine hereafter referred to as the optimizer) to find the combination for which the highest COP is predicted by the heat pump model. In the present study, the set of parameters to be varied include some pertaining to the ground coil as well as some pertaining to the heat pump. The optimizer, in this case, pursues a minimum life cycle cost which is calculated using the heat pump model, a ground coil model (called FTECM for Fast Transient Earth Coil model), and a parameterized cost model. The flow chart shows how the optimizer interacts with these programs to minimize life cycle cost.

  19. Exergetic evaluation of heat pump booster configurations in a low temperature district heating network

    DEFF Research Database (Denmark)

    Ommen, Torben Schmidt; Elmegaard, Brian

    2012-01-01

    In order to minimise losses in a district heating network, one approach is to lower the temperature difference between working media and soil. Considering only direct heat exchange, the minimum forward temperature level is determined by the demand side, as energy services are required at a certain...... temperature. As domestic hot water is required at a temperature range where legionella is no longer a threat, forward temperatures in a traditional low temperature district heating network cannot be lowered beyond approximately 55 ºC. One solution is to boost the temperature of the forward tap water stream...... with a heat pump, as the remaining heat demands are often not required at temperature levels as high as the tap water. The scope of this work is to evaluate the power consumption and second law efficiency of booster heat pumps for tap water production in a low temperature district heating network. The heat...

  20. Heat Pump Clothes Dryer Model Development

    Energy Technology Data Exchange (ETDEWEB)

    Shen, Bo [ORNL

    2016-01-01

    A heat pump clothes dryer (HPCD) is an innovative appliance that uses a vapor compression system to dry clothes. Air circulates in a closed loop through the drum, so no vent is required. The condenser heats air to evaporate moisture out of the clothes, and the evaporator condenses water out of the air stream. As a result, the HPCD can achieve 50% energy savings compared to a conventional electric resistance dryer. We developed a physics-based, quasi-steady-state HPCD system model with detailed heat exchanger and compressor models. In a novel approach, we applied a heat and mass transfer effectiveness model to simulate the drying process of the clothes load in the drum. The system model is able to simulate the inherently transient HPCD drying process, to size components, and to reveal trends in key variables (e.g. compressor discharge temperature, power consumption, required drying time, etc.) The system model was calibrated using experimental data on a prototype HPCD. In the paper, the modeling method is introduced, and the model predictions are compared with experimental data measured on a prototype HPCD.

  1. Heating performance of a ground source heat pump system installed in a school building

    Institute of Scientific and Technical Information of China (English)

    Jaedo; SONG; Kwangho; LEE; Youngman; JEONG; Seongir; CHEONG; Jaekeun; LEE; Yujin; HWANG; Yeongho; LEE; Donghyuk; LEE

    2010-01-01

    The heating performance of a water-to-refrigerant type ground source heat pump system is represented in this paper under the actual working conditions of the GSHP(ground source heat pump) system during the winter season of 2008.Ten heat pump equipments with the capacity of 10 HP each and a closed vertical typed-ground heat exchanger with 24 boreholes of 175 m in depth were constructed.We investigated a variety of working conditions,including the outdoor temperature,the ground temperature,and the water temperature of inlet and outlet of the ground heat exchanger in order to examine the heating performance of the GSHP system.Subsequently,the heating capacity and the input power were investigated to determine the heating performance of the GSHP system.The average heating coefficient of performance(COP) of the heat pump was noted to be 5.1 at partial load of 47%,while the overall system COP was found to be 4.2.Also,performance of the GSHP system was compared with that of air source heat pump.

  2. Cotransporters as molecular water pumps

    DEFF Research Database (Denmark)

    Zeuthen, Thomas; MacAulay, Nanna

    2002-01-01

    Molecular water pumps are membrane proteins of the cotransport type in which a flux of water is coupled to substrate fluxes by a mechanism within the protein. Free energy can be exchanged between the fluxes. Accordingly, the flux of water may be relatively independent of the external water chemical...

  3. The utilization of excess wind-electric power from stock water pumping systems to heat a sector of the stock tank

    Energy Technology Data Exchange (ETDEWEB)

    Nydahl, J.E.; Carlson, B.O. [Univ. of Wyoming, Laramie, WY (United States)

    1996-12-31

    On the high plains, a wind-electric stock water pumping system produces a significant amount of excess power over the winter months due to intense winds and the decreased water consumption by cattle. The University of Wyoming is developing a multi-tasking system to utilize this excess energy to resistively heat a small sector of the stock tank at its demonstration/experimental site. This paper outlines the detailed heat transfer analysis that predicted drinking water temperature and icing conditions. It also outlines the optimization criteria and the power produced by the Bergey 1500 wind electric system. Results show that heating a smaller insulated tank inserted into the larger tank would raise the drinking water temperature by a maximum of 6.7 {degrees}C and eliminate icing conditions. The returns associated with the additional cattle weight gain, as a result of the consumption of warmer water, showed that system modification costs would be recovered the first year. 12 refs., 11 figs., 2 tabs.

  4. Design of Pumps for Water Hydraulic Systems

    DEFF Research Database (Denmark)

    Klit, Peder; Olsen, Stefan; Bech, Thomas Nørgaard

    1999-01-01

    This paper considers the development of two pumps for water hydraulic applications. The pumps are based on two different working principles: The Vane-type pump and the Gear-type pump. Emphasis is put on the considerations that should be made to account for water as the hydraulic fluid.......KEYWORDS: water, pump, design, vane, gear....

  5. Heat-pump-centered integrated community energy systems. Final report

    Energy Technology Data Exchange (ETDEWEB)

    1979-11-01

    A Heat Pump Centered-Integrated Community Energy System (HP-ICES) concept was explored and developed that is based on use of privately owned ice-making heat pumps in each building or complex within a community. These heat pumps will provide all of the space heating, space cooling and domestic hot water needs. All of the community input energy required is provided by electrical power, thereby eliminating a community's dependence on gas or oil supplies. The heat pumps will operate in both air and water source modes, deriving performance advantages of both. The possible forms of an HP-ICES system, the technical and economic limitations, environmental impacts and other factors are discussed from a general viewpoint. The concept is applied to a specific planned community and its performance and economic features are examined in detail. It is concluded that the HP-ICES concept is technically viable, but that its economic desirability as compared with conventional heat pump systems is hampered by much higher initial costs, and that the economic feasibility of HP-ICES systems will depend on future fuel source costs and supply and on electric power rates. (LCL)

  6. High temperature absorption compression heat pump for industrial waste heat

    DEFF Research Database (Denmark)

    Reinholdt, Lars; Horntvedt, B.; Nordtvedt, S. R.

    2016-01-01

    Heat pumps are currently receiving extensive interest because they may be able to support the integration of large shares of fluctuating electricity production based on renewable sources, and they have the potential for the utilization of low temperature waste heat from industry. In most industries......, the needed temperature levels often range from 100°C and up, but until now, it has been quite difficult to find heat pump technologies that reach this level, and thereby opening up the large-scale heat recovery in the industry. Absorption compression heat pumps can reach temperatures above 100°C......, and they have proved themselves a very efficient and reliable technology for applications that have large temperature changes on the heat sink and/or heat source. The concept of Carnot and Lorenz efficiency and its use in the analysis of system integration is shown. A 1.25 MW system having a Carnot efficiency...

  7. Solar-powered Rankine heat pump for heating and cooling

    Science.gov (United States)

    Rousseau, J.

    1978-01-01

    The design, operation and performance of a familyy of solar heating and cooling systems are discussed. The systems feature a reversible heat pump operating with R-11 as the working fluid and using a motor-driven centrifugal compressor. In the cooling mode, solar energy provides the heat source for a Rankine power loop. The system is operational with heat source temperatures ranging from 155 to 220 F; the estimated coefficient of performance is 0.7. In the heating mode, the vapor-cycle heat pump processes solar energy collected at low temperatures (40 to 80 F). The speed of the compressor can be adjusted so that the heat pump capacity matches the load, allowing a seasonal coefficient of performance of about 8 to be attained.

  8. Heat pump contracting: a source of heat that takes care of the climate; Klimaschonende Waermeversorgung

    Energy Technology Data Exchange (ETDEWEB)

    Beyeler, F.

    2003-07-01

    This article discusses heat pump 'contracting solutions' used in the refurbishment of the central heating systems of two housing developments in Zurich and Thun, Switzerland. In these and other projects, the high level of investment needed for the installation of the heat pumps was met by third-party contractors, who install and operate the space heating and domestic hot water systems and sell the heat energy to the tenants. The system serving the 96 'Rietlihof' apartments in Zurich is operated by the public utilities of the City of Zurich, EWZ, the housing development in Thun by the Bernese power utility BKW. The article stresses the importance of professional planning and the correct choice of heat sources. The ecological and economical advantages of heating system refurbishment projects that use heat pumps built, financed and operated by contractors are discussed.

  9. Intelligence on the second stage. 'Air-On' plus air/water heat pump. Cheap air conditioning technology; Intelligenz der zweiten Stufe. 'Air-On' plus Luft/Wasser-Waermepumpe. Preiswerte Raumklimatechnik

    Energy Technology Data Exchange (ETDEWEB)

    Genath, Bernd

    2011-07-15

    It is hard to believe: The heating technique still holds thoughtful surprises. Based on the idea and based on the physics of the heating technology, the company Air-On AG (Cham, Switzerland). For the renovation of old buildings, this company used a second stage of a heat pump to replace old heaters. This second stage is a Peltier element and exclusively tempers a individual room decentrally. The second stage has a better coefficiency of performance than the first stage such as an air / water heat pump.

  10. Applied research of a ground water thermoelectric heat pump system%地下水源热电热泵的应用研究

    Institute of Scientific and Technical Information of China (English)

    马国远

    2001-01-01

    Develops a mathematical model of the system and simulates it with computer based on the state-of-the-art performance of the thermoelectric material, compares the results with those of a conventional ground water heat pump system under the identical inlet water temperature and water flow rate and finds that the thermoelectric system is more competitive especially when the ground water temperature is under 18 ℃ but much poorer in heating performance leading it to be suitable for applications with primary heating demand.%建立了以地下水为热源的热电热泵系统的数学模型,并根据热电材料的技术性能对该系统作了计算机模拟分析,比较计算结果与进水温度和流量相同的传统地下水源热泵系统发现,热电热泵在制冷工况特别是地下水温低于18 ℃时具有很强的竞争力,但制热性能较差,因此适用于全年以制冷负荷为主的场合。

  11. Automatic Control of Water Pumping Stations

    Institute of Scientific and Technical Information of China (English)

    Muhannad Alrheeh; JIANG Zhengfeng

    2006-01-01

    Automatic Control of pumps is an interesting proposal to operate water pumping stations among many kinds of water pumping stations according to their functions.In this paper, our pumping station is being used for water supply system. This paper is to introduce the idea of pump controller and the important factors that must be considering when we want to design automatic control system of water pumping stations. Then the automatic control circuit with the function of all components will be introduced.

  12. THE WATER VAPOR SPECTRUM OF APM 08279+5255: X-RAY HEATING AND INFRARED PUMPING OVER HUNDREDS OF PARSECS

    Energy Technology Data Exchange (ETDEWEB)

    Bradford, C. M.; Bock, J. J.; Naylor, B. J.; Nguyen, H. T.; Zmuidzinas, J. [Jet Propulsion Laboratory, California Institute of Technology, Pasadena, CA 91109 (United States); Bolatto, A. D. [Department of Astronomy, University of Maryland, College Park, MD 20742-2421 (United States); Maloney, P. R.; Aguirre, J. E.; Glenn, J.; Kamenetzky, J. [Center for Astrophysics and Space Astronomy, University of Colorado, Boulder, CO 80303 (United States); Lupu, R.; Scott, K. [Department of Physics, University of Pennsylvania, Philadelphia, PA 19104 (United States); Matsuhara, H. [Institute for Space and Astronautical Science, Japan Aerospace and Exploration Agency, 3-1-1 Yoshinodai, Chuo-ku, Sagamihara 252-5210 (Japan); Murphy, E. J. [Observatories of the Carnegie Institution for Science, 813 Santa Barbara Street, Pasadena, CA 91101 (United States)

    2011-11-10

    We present the rest-frame 200-320 {mu}m spectrum of the z = 3.91 quasar APM 08279+5255, obtained with Z-Spec at the Caltech Submillimeter Observatory. In addition to the J = 8 {yields} 7 to J = 13 {yields} 12 CO rotational transitions which dominate the CO cooling, we find six transitions of water originating at energy levels ranging up to 643 K. Most are first detections at high redshift, and we have confirmed one transition with CARMA. The CO cooling is well described by our X-ray dominated region (XDR) model, assuming L{sub 1-100keV} {approx} 1 Multiplication-Sign 10{sup 46} erg s{sup -1}, and that the gas is distributed over a 550-pc size scale, as per the now-favored {mu} = 4 lensing model. The total observed cooling in water corresponds to 6.5 Multiplication-Sign 10{sup 9} L{sub Sun }, comparable to that of CO. We compare the water spectrum with that of Mrk 231, finding that the intensity ratios among the high-lying lines are similar, but with a total luminosity scaled up by a factor of {approx}50. Using this scaling, we estimate an average water abundance relative to H{sub 2} of 1.4 Multiplication-Sign 10{sup -7}, a good match to the prediction of the chemical network in the XDR model. As with Mrk 231, the high-lying water transitions are excited radiatively via absorption in the rest-frame far-infrared, and we show that the powerful dust continuum in APM 08279+5255 is more than sufficient to pump this massive reservoir of warm water vapor.

  13. Lunar base heat pump, phase 1

    Science.gov (United States)

    Goldman, Jeffrey H.; Harvey, A.; Lovell, T.; Walker, David H.

    1994-01-01

    This report describes the Phase 1 process and analysis used to select a refrigerant and thermodynamic cycle as the basis of a vapor compression heat pump requiring a high temperature lift, then to perform a preliminary design to implement the selected concept, including major component selection. Use of a vapor compression heat pump versus other types was based on prior work performed for the Electric Power Research Institute. A high lift heat pump is needed to enable a thermal control system to remove heat down to 275 K from a habitable volume when the external thermal environment is severe. For example, a long-term lunar base habitat will reject heat from a space radiator to a 325 K environment. The first step in the selection process was to perform an optimization trade study, quantifying the effect of radiator operating temperature and heat pump efficiency on total system mass; then, select the radiator operating temperature corresponding to the lowest system mass. Total system mass included radiators, all heat pump components, and the power supply system. The study showed that lunar night operation, with no temperature lift, dictated the radiator size. To operate otherwise would require a high mass penalty to store power. With the defined radiation surface, and heat pump performances assumed to be from 40 percent to 60 percent of the Carnot ideal, the optimum heat rejection temperature ranged from 387 K to 377 K, as a function of heat pump performance. Refrigerant and thermodynamic cycles were then selected to best meet the previously determined design conditions. The system was then adapted as a ground-based prototype lifting temperature to 360 K (versus 385 K for flight unit) and using readily available commercial-grade components. Over 40 refrigerants, separated into wet and dry compression behavioral types, were considered in the selection process. Refrigerants were initially screened for acceptable critical temperature. The acceptable refrigerants were

  14. Crawl space-assisted heat pumps

    Science.gov (United States)

    McGill, R. N.

    By means of field tests in real houses, it was found that the source air for the heat pump can be preheated (or precooled) by drawing the outdoor air through the crawl space before it is used by the heat pump. The outdoor air is warmed (or cooled) by flowing over the crawl space earth. Most of the data is from winter months, when one would expect the most benefit for heat pump performance. Generally, greater preheating occurs at lower outdoor air temperatures; and, the effect tapers off to virtually no gain at about 10 C. The preheating effect has been shown to be sustained for an entire winter season. Another experiment proved that the preheating does come, in great part, from the earth and not simply from the house above. Analysis had also led to the conclusion that the heat transfer mechanism is by simple conduction within the upper 0.3 m of the crawl space earth.

  15. A review on adsorption heat pump: Problems and solutions

    OpenAIRE

    Demir, Hasan; MOBEDI, Moghtada; Ülkü, Semra

    2008-01-01

    Adsorption heat pumps have considerably sparked attentions in recent years. The present paper covers the working principle of adsorption heat pumps, recent studies on advanced cycles, developments in adsorbent-adsorbate pairs and design of adsorbent beds. The adsorbent-adsorbate pair features for in order to be employed in the adsorption heat pumps are described. The adsorption heat pumps are compared with the vapor compression and absorption heat pumps. The problems and troubles of adsorptio...

  16. Applicability Analysis of Open Type River Water Source Heat Pump System in Chongqing%开式江水源热泵系统在重庆地区的适用性分析

    Institute of Scientific and Technical Information of China (English)

    林勇豹; 王勇

    2013-01-01

      This review summarized the design requirements of open type surface water source heat pump system. Technical, economic and environmental can be considered as the three aspects of the river water source heat pump feasibility analysis. The river water temperature, quantity and other characteristics can meet the requirement of the water source heat pump. In order to ensure the river water source heat pump technology suitability, the key technology is looking for solutions to reduce the sand content. Reasonable design of the water source heat pump system has good economic performance and the tail water discharge can cause less water pollution. The river water source heat pump system has strong feasibility and applicability in Chongqing.%  在总结前人研究的基础上,综述了开式地表水源热泵系统方案设计要求,认为可以从技术、经济和环保性三方面分析江水源热泵的可行性。重庆江水水量、水温等水质参数完全满足机组要求,为了确保江水源热泵在重庆地区的技术适用性,重点在于寻找解决含砂量过高的技术方案。同时,合理设计的水源热泵系统具有较好的经济性能,尾水排放对江水的污染较小,满足经济环保性要求。认为江水源热泵系统在重庆地区具有较强的可行性及适用性。

  17. Development of Air Source Heat Pump Water Heater Performance Test Rig%空气源热泵热水器性能测试系统实验台的研制

    Institute of Scientific and Technical Information of China (English)

    刘笑笑; 丁强

    2015-01-01

    为了满足空气源热泵热水器性能测试的需要,基于对空气源热泵热水器原理、工作特点、热工测试技术、工业控制技术、上位机编写技术等基础,严格参照空气源热泵热水器的相关国家标准设计了一套空气源热泵热水器性能测试系统。该系统不仅能自动计算出被测空气源热泵热水器的性能参数,且具有良好的人机交互界面、可操作性强、性能可靠等优点。%In order to meet the needs of the air source heat pump water heater performance test,according to the work-ing principle of the air source heat pump water heater,working characteristics,thermal testing technology,industrial control technology,computer technology and other related technology,strictly according to the air source heat pump water heater national standards to design a set of water heater performance of air source heat pump test system,it can calculate the performance parameters of the tested air source heat pump water heater automatical y.

  18. Vapor Compression and Thermoelectric Heat Pump Heat Exchangers for a Condensate Distillation System: Design and Experiment

    Science.gov (United States)

    Erickson, Lisa R.; Ungar, Eugene K.

    2013-01-01

    Maximizing the reuse of wastewater while minimizing the use of consumables is critical in long duration space exploration. One of the more promising methods of reclaiming urine is the distillation/condensation process used in the cascade distillation system (CDS). This system accepts a mixture of urine and toxic stabilizing agents, heats it to vaporize the water and condenses and cools the resulting water vapor. The CDS wastewater flow requires heating and its condensate flow requires cooling. Performing the heating and cooling processes separately requires two separate units, each of which would require large amounts of electrical power. By heating the wastewater and cooling the condensate in a single heat pump unit, mass, volume, and power efficiencies can be obtained. The present work describes and compares two competing heat pump methodologies that meet the needs of the CDS: 1) a series of mini compressor vapor compression cycles and 2) a thermoelectric heat exchanger. In the paper, the system level requirements are outlined, the designs of the two heat pumps are described in detail, and the results of heat pump performance tests are provided. A summary is provided of the heat pump mass, volume and power trades and a selection recommendation is made.

  19. Assessment of two-level heat pump installations’ power efficiency for heat supply systems

    Directory of Open Access Journals (Sweden)

    Аlla Е. Denysova

    2015-06-01

    Full Text Available The problem of energy saving becomes one of the most important in power engineering. It is caused by exhaustion of world reserves in hydrocarbon fuel, such as gas, oil and coal representing sources of traditional heat supply. Conventional sources has essential shortcomings: low power, ecological and economic efficiencies, that can be eliminated by using alternative methods of power supply, like the considered one: low-temperature natural heat of ground waters of on the basis of heat pump installations application. The heat supply system considered provides an effective use of two-level heat pump installation operating as heat source the Odessa city ground waters during the lowest ambient temperature period. Proposed is a calculation method of heat pump installations on the basis of geothermal heat supply. Calculated are the values of electric energy consumption N by the compressors’ drive, and the heat supply system transformation coefficient µ for a source of geothermal heat from ground waters of Odessa city allowing to estimate efficiency of two-level heat pump installations.

  20. Heat Radiators for Electromagnetic Pumps

    Science.gov (United States)

    Campana, R. J.

    1986-01-01

    Report proposes use of carbon/carbon composite radiators in electromagnetic coolant pumps of nuclear reactors on spacecraft. Carbon/carbon composite materials function well at temperatures in excess of 2,200 K. Aluminum has melting temperature of only 880 K.

  1. 江水源热泵换热器污垢形成的关键水质因素分析%Key factors of water quality affecting fouling of the river water source pump heat exchanger

    Institute of Scientific and Technical Information of China (English)

    白雪莲; 程可辉

    2012-01-01

    江水引起的热泵换热器结垢不仅会增大枧组进出口阻力,还会导致换热器的换热效率下降.江水水质对换热器污染起决定作用.江水源热泵污垢形成的关键水质因素及相关性分析是热泵用水体评价和水处理决策的基础.通过对重庆地区长江和嘉陵江水质测试分析,并与现行允许水质指标的对比,表明含沙量和浊度是江水源热泵的重点解决问题.对江水源热泵换热器污垢的成份分析则表明,污垢是以小粒径泥沙的颗粒污垢为主.从而确定关键水质因素是含沙量和浊度.根据与实际江水泥沙配置保持一致的自配水样分析,得到了含沙量与浊度的关系方程,误差分析表明预测值与实测值能较好地吻合.%Fouling on heat exchanger of water source heat pump will not only increase resistance of import and export of the units, but also will cause efficiency of the heat exchanger to drop. River water quality plays a decisive role in polluting heat exchanger. The key of water quality factor to the formation of fouling on river water source heat pump and correlation analysis is foundation of water treatment evaluation and decision - making. Annual water quality testing and analysis in the Yangtze River and Jialing River in Chongqing area have been done. With the current allowing the water quality index contrast, comparison shows that the sediment concentration and turbidity is the key to solve the problem of river water source heat pump. Studies have shown that fouling of water source heat pump exchanger are mainly particulate fouling. Main ingredients are small particle size of sediment. Therefore, the sediment concentration and turbidity are identified to be the key factors of quality. For river sediment in accordance with the actual configuration consistent with the analysis of water samples, relationship between sediment concentration and turbidity equation has been obtained. And error analysis shows that

  2. Solar energy and heat pumps: evaluation of combined systems for heating and cooling of buildings

    Energy Technology Data Exchange (ETDEWEB)

    Andrews, J.W.; Catan, M.A.; Le Doux, P.

    1982-09-01

    An analysis of a broad range of solar assisted heat pump systems was carried out. Systems were divided into three categories on the basis of whether ground coupling was included in the system and, if so, whether solar energy was stored in the ground or used in some other way. In the category of non-ground-coupled systems, an advanced air-source heat pump concept designed to improve capacity and coefficient of performance at low source temperatures was used as the basis for a dual source heat pump. For ground coupled systems which do not store solar heat in the ground, three options were considered: use of simple passive techniques to reduce the effective heating load; use of photovoltaics to drive the heat pump compressor; and use of active solar components as a source to the heat pump, for direct space heating, or for domestic hot water only. For systems which do store solar energy in the ground, the minimum size for efficient thermal carryover from summer to winter was determined to be a system capable of serving approx. 100 houses. Use of a fuel-fired heat pump is also an advantage in these larger systems. Economic analyses were based on a maximum allowable payback of 8 years for residential systems. For the large-scale system, a simplified 10-year life-cycle costing was employed.

  3. Combined vapor compression/absorption heat pump cycles for engine-driven heat pumps

    Science.gov (United States)

    Radermacher, Reinhard; Herold, Keith E.; Howe, Lawrence A.

    1988-12-01

    The performance of three combined absorption/vapor compression cycles for gas-fired internal combustion engine driven heat pumps was theoretically assessed. Two cycles were selected for the preliminary design of breadboard systems using only off-the-shelf components. The first cycle, based on the working pair ammonia/water, is termed the simple-cycle. The second cycle, based on the working pair lithium-bromide/water, is termed the compressor enhanced double-effect chiller. Both cycles are found to be technically feasible. The coefficient of performance and the capacity are increased by up to 21 percent for cooling in the first case (compressor efficiency of 0.7) and by up to 14 percent in the second (compressor efficiency of 0.5). Both were compared against the engine drive R22 vapor compression heat pump. The performance of actual machinery for both cycles is, in the current design, hampered by the fact that the desired oil-free compressors have poor isentropic efficiencies. Oil lubricated compressors together with very effective oil separators would improve the performance of the combined LiBr/water cycle to 23 percent.

  4. Energy Optimization for Transcritical CO2 Heat Pump for Combined Heating and Cooling and Thermal Storage Applications

    DEFF Research Database (Denmark)

    Do Carmo, Carolina Madeira Ramos; Blarke, Morten; Yazawa, Kazuaki

    2012-01-01

    A transcritical heat pump (THP) cycle using carbon dioxide (CO2) as the refrigerant is known to feature an excellent coefficient of performance (COP) as a thermodynamic system. Using this feature, we are designing and building a system that combines a water-to-water CO2 heat pump with both hot an...

  5. 太阳能-空气源热泵热水系统节能分析%SOLAR-AIR SOURCE HEAT PUMP HOT WATER SYSTEM ENERGY EFFICIENCY ANALYSIS

    Institute of Scientific and Technical Information of China (English)

    王冠竹; 刘学来

    2011-01-01

    介绍了太阳能生活热水系统,以山东省为例,对太阳能热水器配备空气源热泵的热水系统进行了节能效益分析.结果表明,配备空气源热泵的太阳能热水系统回收期为4.21年,对我国走低碳经济之路有重要的参考价值.%This article describes the solar hot water system. It conducts the energy-saving benefit a-nalysis of solar energy -air source heat pump hot water system. The results show that the payback period of this system is 4.21 years. It has important reference value for going low-carbon economy road in China.

  6. Experimental Study on Performances of Heat Pump Water Heater Based on Heat Recovery of Domestic Wastewater%生活浊水热泵热水器性能的试验研究

    Institute of Scientific and Technical Information of China (English)

    胡敏东; 金苏敏

    2011-01-01

    针对目前生活、洗浴热水的需求不断上涨以及生活洗浴热水废水热存在巨大浪费的现状,介绍了一套新型的回收废水热的热泵热水器及其主要的设备构成.通过对该试验机组进行相关的试验研究,得到组合分离式热管蒸发器废热回收热量与污水质量流量、污水进口温度的变化关系;热泵平均制热量与污水质量流量、污水进口温度变化关系;压缩机吸排气压力及其功率随出热水温度的变化曲线;出热水温度与时间的变化曲线;系统能效比随出热水温度的变化,其平均能效比达到了3.01.与传统的电热水器、燃气热水器以及电辅助加热的热水器产品相比更节能环保.%In order to solve the present situation of unceasing demand for hot water and severe loss of quantity of heat from wastewater, a new type of heat pump water heater was developed based on heat recovery of domestic wastewater. In this paper, the relation curves of waste heat recovery of combined separate heat pipe evaporator, average heating capacity of heat pump, power of compressor, suction and discharge pressure of compressor, outlet temperature of hot water, and energy efficiency ratio of system are investigated experimentally. The average EER of system reaches 3.01, which shows that this type of heat pump water heater is more energy-efficient compared with traditional electric and gas water heater.

  7. Design of serially connected district heating heat pumps utilising a geothermal heat source

    DEFF Research Database (Denmark)

    Jensen, Jonas Kjær; Ommen, Torben Schmidt; Markussen, Wiebke Brix

    2017-01-01

    The design of two heat pumps (HP), connected in series, was investigated for operation in the district heating (DH) network of the Greater Copenhagen area, Denmark. The installation was dimensioned to supply 7.2 MW of heat at a temperature of 85 °C. The heat pumps utilise a geothermal heat source...

  8. Natural thermoelectric heat pump in social wasps.

    Science.gov (United States)

    Ishay, Jacob S; Pertsis, Vitaly; Rave, Eran; Goren, Alon; Bergman, David J

    2003-05-30

    Photographs of wasps or hornets, taken with different temperature sensitive infrared cameras, reveal body temperatures that are sometimes significantly lower than the ambient temperature. This suggests that the hornets possess an intrinsic biological heat pump mechanism which can be used to achieve such cooling. Evidence is presented to substantiate this novel suggestion and to argue that the heat pump is most likely implemented by exploiting a thermoelectric effect in the hornet cuticle. Such a natural heat pump can conceivably also serve to cool the active hornet, engaged in daytime activities outside the nest at ambient temperatures exceeding 40 degrees C, to a body temperature that is low enough to allow its survival in extreme thermal conditions. It might also function as a means of raising the body temperature up to a level that enables the hornet to remain active even when the ambient temperature is as low as 10 degrees C.

  9. Use of solar assisted absorption heat pumps

    Energy Technology Data Exchange (ETDEWEB)

    Lazzarin, R.

    An absorption system can be used for both ambient cooling and heating by solar energy. Heating by an absorption heat pump can represent an interesting alternative, especially in the countries where electric power is not always easily available. Some machines available on the market have been tested. The COP behavior and heating capacity have been examined as a function of the cold source temperature and with regard to different thermal levels. The COP has reached 1.7. Some simulations have been carried out - with two different climatic conditions - to compare the performances of various ''conventional'' solar installation types with solar assisted absorption heat pumps. The series system has shown better performances, 25% to 75%, in comparison with the simpler solar installation. 16 refs.

  10. Technical and Economic Working Domains of Industrial Heat Pumps: Part 1 - Vapour Compression Heat Pumps

    DEFF Research Database (Denmark)

    Ommen, Torben Schmidt; Jensen, Jonas Kjær; Markussen, Wiebke Brix

    2014-01-01

    A large amount of operational and economic constraints limit the applicability of heat pumps operated with natural working fluids. The limitations are highly dependent on the integration of heat source and sink streams. An evaluation of feasible operating conditions is carried out considering...... the constraints of available refrigeration equipment and a requirement of a positive Net Present Value of the investment. The considered sink outlet temperature range is from 40 °C to 140 °C, but for the heat pumps considered in this paper, the upper limit is 100 °C. Five heat pumps are studied. For each set...... of heat sink and source temperatures the optimal solution is determined. At low sink temperature glide R717 heat pumps show best performance, while at higher sink glide transcritical R744 may become important. In a second paper, the results of the VCHP are compared to a similar study considering...

  11. Analysis of Efficiency for Current Heat Pump

    Directory of Open Access Journals (Sweden)

    Vygantas Žėkas

    2011-04-01

    Full Text Available The heat pump is the technology which enables to use renewable energy resources. We can judge about the usage of this technology from the coefficient of performance (COP. It is usually defined according to standard conditions. In this research the actual COP is calculated using thermodynamic analysis method, also performing physical measures of temperatures and pressures of realistically operating thermal pump. This coefficient is analyzed during various characteristic periods of the heating season. The prevailing COP meaning is 3.7-3.9.Article in Lithuanian

  12. Open cycle vapor compression heat pump. Annual report for 1979

    Energy Technology Data Exchange (ETDEWEB)

    Sakhuja, R.; Becker, F.E.

    1980-07-01

    A compressor test facility was built incorporating a screw compressor modified for steam service. The compressor was tested over a wide range of operating conditions with experimental results showing excellent agreement with predicted performance. The compressor operation with wet steam and water injection was completely satisfactory, demonstrating its suitability for use in a steam heat pump system.

  13. Modelling of Split Condenser Heat Pump with Limited Set of Plate Heat Exchanger Dimensions

    DEFF Research Database (Denmark)

    Christensen, Stefan Wuust; Elmegaard, Brian; Markussen, Wiebke Brix

    2017-01-01

    This paper presents a numerical study of optimal plate dimensions in a split condenser heat pump (SCHP), using ammonia as refrigerant. The SCHP setup differs from a traditional heat pump (THP) setup in the way that two separate water streams on the secondary side of the condenser are heated...... in parallel to different temperature levels, whereas only one stream is heated in a THP. The length/width ratio of the plate heat exchangers on the high pressure side of a SCHP was investigated to find the optimal plate dimensions with respect to minimum area of the heat exchangers. The total heat exchanger...... area was found to decrease with an increasing length/width ratio of the plates. The marginal change in heat exchanger area was shown to be less significant for heat exchangers with high length/width ratios. In practice only a limited number of plate dimensions are available and feasible...

  14. An analysis of Water Supply Heat Pump's Capability of Energy Storage and Energy Saving Using Electricity%水源热泵系统蓄能节能的可行性

    Institute of Scientific and Technical Information of China (English)

    吴薇; 张小松

    2002-01-01

    In this paper, the characteristic of water supply heat pump (WLHP) is introduced. The thermal performanceand effect of energy saving that can be used to heating and cooling at the same time (the distinctive working mode) is em-phasized. A new idea of heat input using wave trough electricity instead of boilers is brought up, the effect and significance ofthis new method is discussed.

  15. Empirical Platform Data Analysis to Investigate how Heat Pumps Operate in Real-Life Conditions

    DEFF Research Database (Denmark)

    Carmo, Carolina; Elmegaard, Brian; Nielsen, M. P.

    2015-01-01

    Heat pumps have been widely acknowledged, by academia and industry, as highly efficient thermal energy technologies, for space heating and domestic hot water production. However, there is a lack of information about real performance in residential single family houses with active participation...... the suitability of heat pumps to support fossil-fuel free energy systems....

  16. Control System for Solar-Assisted Heat Pump System.

    Science.gov (United States)

    heat pump , a water-to-air heat exchanger, a domestic water heater, and a cooling tower. The preferred embodiment of the controller of the present invention includes a first temperature sensing means for sensing the temperature of the collector fluid at the outlet of the solar collector system, a second temperature sensing means for sensing the temperature of the storage fluid at the thermal storage system, and a third temperature sensing means for sensing the temperature of the inlet water to the domestic water heater. The controller compares the temperature of the thermal

  17. Analysis of Decentralized Control for Absorption Cycle Heat Pumps

    DEFF Research Database (Denmark)

    Vinther, Kasper; Just Nielsen, Rene; Nielsen, Kirsten Mølgaard

    2015-01-01

    Email Print Request Permissions This paper investigates decentralized control structures for absorption cycle heat pumps and a dynamic nonlinear model of a single-effect LiBr-water absorption system is used as case study. The model has four controllable inputs, which can be used to stabilize...... the operation of the heat pump under different load conditions. Different feasible input-output pairings are analyzed by computation of relative gain array matrices and scaled condition numbers, which indicate the best pairing choice and the potential of each input-output set. Further, it is possible...... to minimize the effect of cross couplings and improve stability with the right pairing of input and output. Simulation of selected candidate input-output pairings demonstrate that decentralized control can provide stable operation of the heat pump....

  18. Performance of a solar augmented heat pump

    Science.gov (United States)

    Bedinger, A. F. G.; Tomlinson, J. J.; Reid, R. L.; Chaffin, D. J.

    Performance of a residential size solar augmented heat pump is reported for the 1979-1980 heating season. The facility located in Knoxville, Tennessee, has a measured heat load coefficient of 339.5 watt/C (644 BTU/hr- F). The solar augmented heat pump system consists of 7.4 cu m of one inch diameter crushed limestone. The heat pump is a nominal 8.8 KW (2 1/2 ton) high efficiency unit. The system includes electric resistance heaters to give the option of adding thermal energy to the pebble bed storage during utility off-peak periods, thus offering considerable load management capability. A 15 KW electric resistance duct heater is used to add thermal energy to the pebble bin as required during off-peak periods. Hourly thermal performance and on site weather data was taken for the period November 1, 1979, to April 13, 1980. Thermal performance data consists of heat flow summations for all modes of the system, pebble bed temperatures, and space temperature. Weather data consists of dry bulb temperature, dew point temperature, total global insolation (in the plane of the collector), and wind speed and direction. An error analysis was performed and the least accurate of the measurements was determined to be the heat flow at 5%. Solar system thermal performance factor was measured to be 8.77. The heat pump thermal performance factor was 1.64. Total system seasonal performance factor was measured to be 1.66. Using a modified version of TRNSYS, the thermal performance of this system was simulated. When simulation results were compared with data collected onsite, the predicted heat flow and power consumption generally were within experimental accuracy.

  19. Mass and Heat Transfer Enhancement of Chemical Heat Pumps

    Institute of Scientific and Technical Information of China (English)

    Gui-PingLin; Xiu-GanYuan

    1993-01-01

    An inert additive,expanded graphit(EG),has been prepared and used to enhance the heat and mass transfer process of chemical heat pumps.The effects of mixing ratio and mixing method on the chemical reaction time are investigated.

  20. Practical and efficient magnetic heat pump

    Science.gov (United States)

    Brown, G. V.

    1978-01-01

    Method for pumping heat magnetically at room temperature is more economical than existing refrigeration systems. Method uses natural magneto-thermal effect of gadolinium metal to establish temperature gradient across length of tube. Regenerative cyclic process in which gadolinium sample is magnetized and gives off heat at one end of tube, and then is demagnetized at other end to absorb heat has established temperature gradients of 144 degrees F in experiments near room temperature. Other materials with large magnetothermal effects can be used below room temperature. Possible commercial applications include freeze-drying and food processing, cold storage, and heating and cooling of buildings, plants, and ships.

  1. Practical and efficient magnetic heat pump

    Science.gov (United States)

    Brown, G. V.

    1978-01-01

    Method for pumping heat magnetically at room temperature is more economical than existing refrigeration systems. Method uses natural magneto-thermal effect of gadolinium metal to establish temperature gradient across length of tube. Regenerative cyclic process in which gadolinium sample is magnetized and gives off heat at one end of tube, and then is demagnetized at other end to absorb heat has established temperature gradients of 144 degrees F in experiments near room temperature. Other materials with large magnetothermal effects can be used below room temperature. Possible commercial applications include freeze-drying and food processing, cold storage, and heating and cooling of buildings, plants, and ships.

  2. Microgravity heat pump for space station thermal management.

    Science.gov (United States)

    Domitrovic, R E; Chen, F C; Mei, V C; Spezia, A L

    2003-01-01

    A highly efficient recuperative vapor compression heat pump was developed and tested for its ability to operate independent of orientation with respect to gravity while maximizing temperature lift. The objective of such a heat pump is to increase the temperature of, and thus reduce the size of, the radiative heat rejection panels on spacecrafts such as the International Space Station. Heat pump operation under microgravity was approximated by gravitational-independent experiments. Test evaluations include functionality, efficiency, and temperature lift. Commercially available components were used to minimize costs of new hardware development. Testing was completed on two heat pump design iterations--LBU-I and LBU--II, for a variety of operating conditions under the variation of several system parameters, including: orientation, evaporator water inlet temperature (EWIT), condenser water inlet temperature (CWIT), and compressor speed. The LBU-I system employed an ac motor, belt-driven scroll compressor, and tube-in-tube heat exchangers. The LBU-II system used a direct-drive AC motor compressor assembly and plate heat exchangers. The LBU-II system in general outperformed the LBU-I system on all accounts. Results are presented for all systems, showing particular attention to those states that perform with a COP of 4.5 +/- 10% and can maintain a temperature lift of 55 degrees F (30.6 degrees C) +/- 10%. A calculation of potential radiator area reduction shows that points with maximum temperature lift give the greatest potential for reduction, and that area reduction is a function of heat pump efficiency and a stronger function of temperature lift.

  3. The cost-effectiveness of heat pumps in specific buildings in South Africa

    Energy Technology Data Exchange (ETDEWEB)

    Greyvenstein, G.P.; Meyer, J.P. (Potchefstroom Univ. for CHE (South Africa). Dept. of Mechanical Engineering)

    1993-09-01

    Water heating heat pumps are extremely energy efficient and large savings can be realized when they are compared to direct electrical resistance heaters. In spite of the energy efficiency of heat pumps, a large number of residential buildings in South Africa still use electrical heaters to heat water. The reason for this is that heat pumps are considerably more expensive than electrical heaters. Building owners tend to choose the system with the smallest initial cost and do not compare the two systems on the basis of life-cycle cost. It is also difficult to calculate the life-cycle cost of a heat pump because it depends on many factors like climatological conditions and water temperature. In this paper a methodology is developed to calculate the life-cycle cost of a heat pump hot water installation. The model is used to investigate the effect of daily runtime, electricity tariff, hot water consumption and geographical location on the cost-effectiveness of heat pumps. The cost-effectiveness of heat pumps increases with daily run time, water consumption and electricity tariff. Heat pumps are more cost-effective near the coast than in the interior. If sized correctly, heat pumps are more cost-effective than electrical heaters for all major cities in South Africa. The cost-effectiveness of heat pumps for two specific buildings, one a university student hostel in Potchefstroom and the other a hotel in Durban, is also investigated. For both cases it was found that heat pumps are more cost-effective than direct electrical resistance heaters. (author)

  4. Heat pumps: Industrial applications. (Latest citations from the NTIS bibliographic database). Published Search

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-04-01

    The bibliography contains citations concerning design, development, and applications of heat pumps for industrial processes. Included are thermal energy exchanges based on air-to-air, ground-coupled, air-to-water, and water-to-water systems. Specific applications include industrial process heat, drying, district heating, and waste processing plants. Other Published Searches in this series cover heat pump technology and economics, and heat pumps for residential and commercial applications. (Contains 50-250 citations and includes a subject term index and title list.) (Copyright NERAC, Inc. 1995)

  5. Recovery Act: Tennessee Energy Efficient Schools Initiative Ground Source Heat Pump Program

    Energy Technology Data Exchange (ETDEWEB)

    Townsend, Terry [Townsend Engineering, Inc., Davenport, IA (United States); Slusher, Scott [Townsend Engineering, Inc., Davenport, IA (United States)

    2017-04-24

    The Tennessee Energy Efficient Schools Initiative (EESI) Hybrid-Water Source Heat Pump (HY-GSHP) Program sought to provide installation costs and operation costs for different Hybrid water source heat pump systems’ configurations so that other State of Tennessee School Districts will have a resource for comparison purposes if considering a geothermal system.

  6. Heat Pumps in CHP Systems

    DEFF Research Database (Denmark)

    Ommen, Torben Schmidt

    in Danish conditions. The limitations are highly dependent on the integration of heat source and sink streams. An evaluation of feasible operating conditions was carried out considering the constraints of available refrigeration equipment and a requirement of a positive net present value of the investment...... goals. The presented study investigates the possible introduction of HPs from both a thermodynamic and a system/operation management perspective, in order to find optimal integration schemes in both current and future energy scenarios. Five generic configurations of HPs in district heating (DH) systems...... that three configurations are particular advantageous, whereas the two remaining configurations result in system performance close to or below what may be expected from an electric heater. One of the three advantageous configurations is required to be positioned at the location of the heat demand, whereas...

  7. Heat pump evaluation for Space Station ATCS evolution

    Science.gov (United States)

    Ames, Brian E.; Petete, Patricia A.

    1991-01-01

    A preliminary feasibility assessment of the application of a vapor compression heat pump to the Active Thermal Control System (ATCS) of SSF is presented. This paper focuses on the methodology of raising the surface temperature of the radiators for improved heat rejection. Some of the effects of the vapor compression cycle on SSF examined include heat pump integration into ATCS, constraints on the heat pump operating parameters, and heat pump performance enhancements.

  8. Heat pump evaluation for Space Station ATCS evolution

    Science.gov (United States)

    Ames, Brian E.; Petete, Patricia A.

    1991-01-01

    A preliminary feasibility assessment of the application of a vapor compression heat pump to the Active Thermal Control System (ATCS) of SSF is presented. This paper focuses on the methodology of raising the surface temperature of the radiators for improved heat rejection. Some of the effects of the vapor compression cycle on SSF examined include heat pump integration into ATCS, constraints on the heat pump operating parameters, and heat pump performance enhancements.

  9. Dual-stroke heat pump field performance

    Science.gov (United States)

    Veyo, S. E.

    1984-11-01

    Two nearly identical proprototype systems, each employing a unique dual-stroke compressor, were built and tested. One was installed in an occupied residence in Jeannette, Pa. It has provided the heating and cooling required from that time to the present. The system has functioned without failure of any prototypical advanced components, although early field experience did suffer from deficiencies in the software for the breadboard micro processor control system. Analysis of field performance data indicates a heating performance factor (HSPF) of 8.13 Stu/Wa, and a cooling energy efficiency (SEER) of 8.35 Scu/Wh. Data indicate that the beat pump is oversized for the test house since the observed lower balance point is 3 F whereas 17 F La optimum. Oversizing coupled with the use of resistance heat ot maintain delivered air temperature warmer than 90 F results in the consumption of more resistance heat than expected, more unit cycling, and therefore lower than expected energy efficiency. Our analysis indicates that with optimal mixing the dual stroke heat pump will yield as HSFF 30% better than a single capacity heat pump representative of high efficiency units in the market place today for the observed weather profile.

  10. A regenerative elastocaloric heat pump

    DEFF Research Database (Denmark)

    Engelbrecht, Kurt; Eriksen, Dan; Dallolio, Stefano

    2016-01-01

    A large fraction of global energy use is for refrigeration and air-conditioning, which could be decarbonized if efficient renewable energy technologies could be found. Vapour-compression technology remains the most widely used system to move heat up the temperature scale after more than 100 years...

  11. Manually operated elastomer heat pump

    Science.gov (United States)

    Hutchinson, W. D.

    1970-01-01

    Device consisting of a rotating mechanism, a frame with multiple wide bands of rubber, and a fluid bath, demonstrates the feasibility of a human operated device capable of cooling or producing heat. This invention utilizes the basic thermodynamic properties of natural rubber.

  12. Residential Variable-Capacity Heat Pumps Sized to Heating Loads

    Energy Technology Data Exchange (ETDEWEB)

    Munk, Jeffrey D. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Jackson, Roderick K. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Odukomaiya, Adewale [Georgia Inst. of Technology, Atlanta, GA (United States); Gehl, Anthony C. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2014-01-01

    Variable capacity heat pumps are an emerging technology offering significant energy savings potential and improved efficiency. With conventional single-speed systems, it is important to appropriately size heat pumps for the cooling load as over-sizing would result in cycling and insufficient latent capacity required for humidity control. These appropriately sized systems are often under-sized for the heating load and require inefficient supplemental electric resistance heat to meet the heating demand. Variable capacity heat pumps address these shortcomings by providing an opportunity to intentionally size systems for the dominant heating season load without adverse effects of cycling or insufficient dehumidification in the cooling season. This intentionally-sized system could result in significant energy savings in the heating season, as the need for inefficient supplemental electric resistance heat is drastically reduced. This is a continuation of a study evaluating the energy consumption of variable capacity heat pumps installed in two unoccupied research homes in Farragut, a suburb of Knoxville, Tennessee. In this particular study, space conditioning systems are intentionally sized for the heating season loads to provide an opportunity to understand and evaluate the impact this would have on electric resistance heat use and dehumidification. The results and conclusions drawn through this research are valid and specific for portions of the Southeastern and Midwestern United States falling in the mixed-humid climate zone. While other regions in the U.S. do not experience this type of climate, this work provides a basis for, and can help understand the implications of other climate zones on residential space conditioning energy consumption. The data presented here will provide a framework for fine tuning residential building EnergyPlus models that are being developed.

  13. Residential Variable-Capacity Heat Pumps Sized to Heating Loads

    Energy Technology Data Exchange (ETDEWEB)

    Munk, Jeffrey D. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Jackson, Roderick K. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Odukomaiya, Adewale [Georgia Inst. of Technology, Atlanta, GA (United States); Gehl, Anthony C. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2014-01-01

    Variable capacity heat pumps are an emerging technology offering significant energy savings potential and improved efficiency. With conventional single-speed systems, it is important to appropriately size heat pumps for the cooling load as over-sizing would result in cycling and insufficient latent capacity required for humidity control. These appropriately sized systems are often under-sized for the heating load and require inefficient supplemental electric resistance heat to meet the heating demand. Variable capacity heat pumps address these shortcomings by providing an opportunity to intentionally size systems for the dominant heating season load without adverse effects of cycling or insufficient dehumidification in the cooling season. This intentionally-sized system could result in significant energy savings in the heating season, as the need for inefficient supplemental electric resistance heat is drastically reduced. This is a continuation of a study evaluating the energy consumption of variable capacity heat pumps installed in two unoccupied research homes in Farragut, a suburb of Knoxville, Tennessee. In this particular study, space conditioning systems are intentionally sized for the heating season loads to provide an opportunity to understand and evaluate the impact this would have on electric resistance heat use and dehumidification. The results and conclusions drawn through this research are valid and specific for portions of the Southeastern and Midwestern United States falling in the mixed-humid climate zone. While other regions in the U.S. do not experience this type of climate, this work provides a basis for, and can help understand the implications of other climate zones on residential space conditioning energy consumption. The data presented here will provide a framework for fine tuning residential building EnergyPlus models that are being developed.

  14. Aggregated Control of Domestic Heat Pumps

    DEFF Research Database (Denmark)

    Nielsen, Kirsten M.; Andersen, Palle; Pedersen, Tom S.

    2013-01-01

    A challenge in Denmark in the near future is to balance the electrical grid due to a large increase in the renewable energy production mainly from wind turbines. In this work an aggregated control system using heat pumps in single family houses to help balancing the grid is investigated. The cont...

  15. Multi-Function Gas Fired Heat Pump

    Energy Technology Data Exchange (ETDEWEB)

    Mehdizadeh Momen, Ayyoub [ORNL; Abu-Heiba, Ahmad [ORNL; Vineyard, Edward Allan [ORNL

    2015-11-01

    The aim of this project was to design a residential fuel fired heat pump and further improve efficiency in collaboration with an industry partner – Southwest Gas, the developer of the Nextaire commercial rooftop fuel-fired heat pump. Work started in late 2010. After extensive search for suitable engines, one manufactured by Marathon was selected. Several prototypes were designed and built over the following four years. Design changes were focused on lowering the cost of components and the cost of manufacturing. The design evolved to a final one that yielded the lowest cost. The final design also incorporates noise and vibration reduction measures that were verified to be effective through a customer survey. ETL certification is currently (as of November 2015) underway. Southwest Gas is currently in talks with GTI to reach an agreement through which GTI will assess the commercial viability and potential of the heat pump. Southwest Gas is searching for investors to manufacture the heat pump and introduce it to the market.

  16. Heat pumps in industry: Pt. 1; Equipment

    Energy Technology Data Exchange (ETDEWEB)

    Lazzarin, R.M. (Padua Univ. (Italy). Ist. di Ingegneria Gestionale)

    1994-11-01

    Industrial heat pumps are reviewed, classifying them according to the way by which the working fluid is taken from the lower to the higher pressure: mechanical or thermal. Each group is further subdivided in closed and open cycle. The most recent technological developments are considered for each classification. (author)

  17. Multi-Function Gas Fired Heat Pump

    Energy Technology Data Exchange (ETDEWEB)

    Abu-Heiba, Ahmad [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Vineyard, Edward Allan [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2015-11-30

    The aim of this project was to design a residential fuel fired heat pump and further improve efficiency in collaboration with an industry partner – Southwest Gas, the developer of the Nextaire commercial rooftop fuel-fired heat pump. Work started in late 2010. After extensive search for suitable engines, one manufactured by Marathon was selected. Several prototypes were designed and built over the following four years. Design changes were focused on lowering the cost of components and the cost of manufacturing. The design evolved to a final one that yielded the lowest cost. The final design also incorporates noise and vibration reduction measures that were verified to be effective through a customer survey. ETL certification is currently (as of November 2015) underway. Southwest Gas is currently in talks with GTI to reach an agreement through which GTI will assess the commercial viability and potential of the heat pump. Southwest Gas is searching for investors to manufacture the heat pump and introduce it to the market.

  18. Solar Assisted Water Source Heat Pump System for Heating in Winter%关于太阳能辅助水源热泵系统联合冬季供暖的研究

    Institute of Scientific and Technical Information of China (English)

    石东森; 赵展

    2014-01-01

    Along with the increased awareness of energy shortage and environmental protection in China, solar energy and shallow geothermal energy as renewable energy are getting more and more atten-tion. But regardless of the solar system or single water source heat pump system has some limitations, few of joint operation for both applications. Based on the actual project as an example, the solar system can be combined with water source heat pump system, and the system will achieve the required indoor air temper-ature; and the technical analysis of operation cost for solar system with water source heat pump system shows the energy efficiency is completely obvious.%随着我国能源的紧缺和环保意识的加强,太阳能、浅层地热能作为可再生能源,越来越受到人们的重视。但无论是太阳能系统,还是水源热泵系统,单独运行时均有一定的局限性,两者联合运行的应用很少。通过实际工程分析,太阳能系统与水源热泵系统可以联合工作,并可达到预期的室内空调温度;对太阳能系统与水源热泵系统联合运行的运行费用做了技术分析,证实这种联合模式节能效果十分明显。

  19. 'Pioneer' - A controlled air-water heat pump for the replacement of oil-fired and electric heating systems; Geregelte Waermepumpe Pioneer. Geregelte Luft-Wasser-Waermepumpe fuer Sanierungen von Oel- und Elektroheizungen - Schlussbericht

    Energy Technology Data Exchange (ETDEWEB)

    Boeckh, P. von; Borer, M.; Borer, T. [Fachhochschule beider Basel FHBB, Dept. Industrie, Abtlg. Maschinenbau, Muttenz (Switzerland); Eggenberger, H.J. [Solartis GmbH, WP-Versuchslabor EICH, Fuellinsdorf (Switzerland)

    2005-07-01

    This final report for the Swiss Federal Office of Energy (SFOE) presents the results of a project that involved the development of an air-water heat pump system that could replace existing oil-fired and electric heating systems. The system features variable-frequency compressor and ventilator drives and was tested on a special test bed that provided appropriately prepared primary air. The measurements and optimisations made included the definition of optimal parameters for ventilator and de-icing system, measurement of performance coefficients and noise emissions as well as on the suitability of the system for hot-water generation. The authors quote figures that show that the performance of the variable-speed system is much better than systems running in stop-and-go mode.

  20. Heat transfer analysis of underground U-type heat exchanger of ground source heat pump system.

    Science.gov (United States)

    Pei, Guihong; Zhang, Liyin

    2016-01-01

    Ground source heat pumps is a building energy conservation technique. The underground buried pipe heat exchanging system of a ground source heat pump (GSHP) is the basis for the normal operation of an entire heat pump system. Computational-fluid-dynamics (CFD) numerical simulation software, ANSYS-FLUENT17.0 have been performed the calculations under the working conditions of a continuous and intermittent operation over 7 days on a GSHP with a single-well, single-U and double-U heat exchanger and the impact of single-U and double-U buried heat pipes on the surrounding rock-soil temperature field and the impact of intermittent operation and continuous operation on the outlet water temperature. The influence on the rock-soil temperature is approximately 13 % higher for the double-U heat exchanger than that of the single-U heat exchanger. The extracted energy of the intermittent operation is 36.44 kw·h higher than that of the continuous mode, although the running time is lower than that of continuous mode, over the course of 7 days. The thermal interference loss and quantity of heat exchanged for unit well depths at steady-state condition of 2.5 De, 3 De, 4 De, 4.5 De, 5 De, 5.5 De and 6 De of sidetube spacing are detailed in this work. The simulation results of seven working conditions are compared. It is recommended that the side-tube spacing of double-U underground pipes shall be greater than or equal to five times of outer diameter (borehole diameter: 180 mm).

  1. Modelling of Ammonia Heat Pump Desuperheaters

    DEFF Research Database (Denmark)

    Christensen, Stefan Wuust; Elmegaard, Brian; Markussen, Wiebke Brix

    2015-01-01

    This paper presents a study of modelling desuperheating in ammonia heat pumps. Focus is on the temperature profile of the superheated refrigerant. Typically, the surface area of a heat exchanger is estimated using the Log Mean Temperature Difference (LMTD) method. The assumption of this method...... is that the specific heat is constant throughout the temperature glide of the refrigerant in the heat exchanger. However, considering ammonia as refrigerant, the LMTD method does not give accurate results due to significant variations of the specific heat. By comparing the actual temperature profiles from a one....... The area of the heat exchanger can be increased or the condensation temperature can be raised to achieve the same temperature difference for the discretized model as for the LMTD. This would affect the compressor work, hence the COP of the system. Furthermore, for higher condenser pressure, and thus higher...

  2. Recovery Act - Geothermal Technologies Program: Ground Source Heat Pumps Final Scientific/Technical Report

    Energy Technology Data Exchange (ETDEWEB)

    Nick Rosenberry, Harris Companies

    2012-05-04

    A large centralized geothermal heat pump system was installed to provide ice making, space cooling, space heating, process water heating, and domestic hot water heating for an ice arena in Eagan Minnesota. This paper provides information related to the design and construction of the project. Additionally, operating conditions for 12 months after start-up are provided.

  3. Performance of a solar augmented heat pump

    Science.gov (United States)

    Bedinger, A. F. G.; Tomlinsin, J. J.; Reid, R. L.; Chaffin, D. J.

    Performance results from a test house equipped with a parallel solar augmented heat pump system with off-peak storage and a utility interconnection back-up, are presented. The collector array consisted of 12 air heating flat plates with a 9 l/sec flow. Thermal storage was consigned to a 260 cu ft crushed limestone pebble bed, with an 8.8 kW heat pump used to draw heat from storage during off-peak hours and a 15 kW electrical resistance heater used to charge the pebble bed. Monitoring and data recording were carried out on all energy inputs and outputs of the systems, and a modified TRNSYS program was employed to model the system performance. The data indicate that although the system offered the possibility of reducing the utility capacity, the addition of the solar system did not significantly augment the performance of the heat-pump system, at least in terms of the cost of supplementary electricity.

  4. Comfort-constrained distributed heat pump management

    CERN Document Server

    Parkinson, Simon; Crawford, Curran; Djilali, Ned

    2011-01-01

    This paper introduces the design of a demand response network control strategy aimed at thermostatically controlled electric heating and cooling systems in buildings. The method relies on the use of programmable communicating thermostats, which are able to provide important component-level state variables to a system-level central controller. This information can be used to build power density distribution functions for the aggregate heat pump load. These functions lay out the fundamental basis for the methodology by allowing for consideration of customer-level constraints within the system-level decision making process. The proposed strategy is then implemented in a computational model to simulate a distribution of buildings, where the aggregate heat pump load is managed to provide the regulation services needed to successfully integrate wind power generators. Increased exploitation of wind resources will place similarly themed ancillary services in high-demand, traditionally provided by dispatchable energy ...

  5. DOE Webinar - Residential Geothermal Heat Pump Retrofits (Presentation)

    Energy Technology Data Exchange (ETDEWEB)

    Anderson, E. R.

    2010-12-14

    This presentation was given December 14, 2010, as part of DOE's Webinar series. The presentation discusses geothermal heat pump retrofits, technology options, and an overview of geothermal energy and geothermal heat pumps.

  6. The use of new refrigerants in high-temperature heat pumps for heating water up to 80 degrees C in chocolate factories; L`utilisation des nouveaux frigorigenes en pompes a chaleur a haute temperature : production d`eau chaude a 80 degres C en chocolaterie

    Energy Technology Data Exchange (ETDEWEB)

    Blaise; Dutto [EDF, 75 - Paris (France); Lindt; Michel [Safrair (France)

    1992-12-31

    A cascade refrigeration system utilizing a new refrigerant, R142b (difluorochloroethane), in heating and cooling of water with heat pumps, was described. R142b has been extensively tested by Electricite de France (EDF) since 1984. The heat-carrying fluid can produce hot air or water up to 90 degrees C from a source between 30 and 50 degrees C. It is non-toxic and has low ozone depleting potential and low global warming potential. The utilisation of R142b along with R22 in the industrial heat pumps installations of a French chocolate factory with demanding needs in both hot and cold water have demonstrated that it is possible to produce hot water in the range of 50 to 80 degrees C without CFCs in heat pump installations. 1 tab., 1 fig.

  7. Radon as a tracer to characterize the interactions between groundwater and surface water around the ground source heat pump system in riverside area

    Science.gov (United States)

    Kim, Jaeyeon; Lee, Seong-Sun; Lee, Kang-Kun

    2016-04-01

    The interaction characteristics between groundwater and surface water was examined by using Radon-222 at Han River Environmental Research Center (HRERC) in Korea where a geothermal resource using indirect open loop ground source heat pump (GSHP) has been developed. For designing a high efficiency performance of the open loop system in shallow aquifer, the riverside area was selected for great advantage of full capacity of well. From this reason groundwater properties of the study site can be easily influenced by influx of surrounding Han River. Therefore, 12 groundwater wells were used for monitoring radon concentration and groundwater level with fluctuation of river stage from May, 2014 to Apr., 2015. The short term monitoring data showed that the radon concentration was changed in accordance with flow meter data which was reflected well by the river stage fluctuation. The spatial distribution of radon concentration from long term monitoring data was also found to be affected by water level fluctuation by nearby dam activity and seasonal effect such as heavy rainfall and groundwater pumping. The estimated residence time indicates that river flows to the study site change its direction according to the combined effect of river stage and groundwater hydrology. In the linear regression of the values, flow velocities were yielded around 0.04 to 0.25 m/day which were similar to flow meter data. These results reveal that Radon-222 can be used as an appropriate environmental tracer in examining the characteristics of interaction in consideration of fluctuating river flow on operation of GSHP in the riverside area. ACKNOWLEDGEMENT This work was supported by the research project of "Advanced Technology for Groundwater Development and Application in Riversides (Geowater+) in "Water Resources Management Program (code 11 Technology Innovation C05)" of the MOLIT and the KAIA in Korea.

  8. Apartment block with heat-pumps and solar energy; Mit Waermepumpe und Sonnenenergienutzung

    Energy Technology Data Exchange (ETDEWEB)

    Haltiner, E. W.

    2008-07-01

    This article takes a look at how the owner of an apartment block in Zurich, Switzerland has moved away from conventional heating-oil and installed two air/water heat pumps and 36 m{sup 2} of solar collectors to provide the necessary heating power and domestic hot water. The new installation, which also features speed-controlled circulation pumps in the heating circuit is briefly described. Subsidies received and tax-saving aspects are discussed. The heat pumps, which use the Enhanced Vapour Injection EVI system are briefly looked at. This system allows higher flow temperatures to be attained.

  9. Measurement and Evaluation of Heating Performance of Heat Pump Systems Using Wasted Heat from Electric Devices for an Electric Bus

    Directory of Open Access Journals (Sweden)

    Moo-Yeon Lee

    2012-03-01

    Full Text Available The objective of this study is to investigate heating performance characteristics of a coolant source heat pump using the wasted heat from electric devices for an electric bus. The heat pump, using R-134a, is designed for heating a passengers’ compartment by using discharged energy from the coolant of electric devices, such as motors and inverters of the electric bus. The heating performance of the heat pump was tested by varying the operating parameters, such as outdoor temperature and volume flow rate of the coolant water of the electrical devices. Heating capacity, compressor work, and heating COP were measured; their behaviors with regard to the parameters were observed. Experimental results showed that heating COP increased with decrease of outdoor temperature, from 20.0 °C to 0 °C, and it observed to be 3.0 in the case of 0 °C outdoor temperature. The observed characteristics of the heating COP suggest that the heat pump is applicable as the cabin heater of an electric vehicle, which is limited by short driving range.

  10. Experimental study on energy performance of clean air heat pump

    DEFF Research Database (Denmark)

    Fang, Lei; Nie, Jinzhe; Olesen, Bjarne W.

    2014-01-01

    An innovative clean air heat pump (CAHP) was designed and developed based on the air purification capacity of regenerative silica gel rotor. The clean air heat pump integrated air purification, dehumidification and cooling in one unit. A prototype of the clean air heat pump was developed...

  11. Malone-Brayton Cycle Engine/Heat Pump.

    Science.gov (United States)

    A machine, such as a heat pump , and having an all liquid heat exchange fluid, operates over a more nearly ideal thermodynamic cycle by adjustment of...difference in axial lengths of rotary pumps of the gear or vane type to achieve the adjustment of volumetric capacity. Adjustment of the heat pump system

  12. Reflection of ground-source heat pump systems' application

    Institute of Scientific and Technical Information of China (English)

    ZHANGSuyun; LINZhenguo; WUXiangsheng; WUTian

    2003-01-01

    Ground-source heat pump system is an air-conditioning form of energy efficient and environment protection. This article introduced the forms of ground-source heat pump systems, analyzed the problems of ground-source heat pump systems in application in China, and put forward the solutions to these problems.

  13. A mixed air/air and air/water heat pump system ensures the air-conditioning of a cinema; Un systeme mixte PAC air/air et air/eau climatise un cinema

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    2001-03-01

    This article presents the air conditioning system of a new cinema complex of Boulogne (92, France) which comprises a double-flux air processing plant and two heat pumps. Each heat pump has two independent refrigerating loops: one with a air condenser and the other with a water condenser. This system allows to limit the power of the loop and to reduce the size of the cooling tower and of the vertical ducts. This article describes the technical characteristics of the installation: thermodynamic units, smoke clearing, temperature control, air renewing. (J.S.)

  14. NGTC`s natural gas heat pumps

    Energy Technology Data Exchange (ETDEWEB)

    Binet, M. [Natural Gas Technologies Centre, Boucherville, PQ (Canada)

    1996-12-01

    An overview of natural gas heat pumps and cooling systems evaluation projects carried out by the Natural Gas Technologies Centre (NGTC) in Boucherville, Quebec, was presented. Technological description of three natural gas engine-driven technologies were provided, as well as the results of laboratory and field tests. The residential sector was covered by the 3-ton York Triathlon heat pump, the commercial sector by the 10-ton Trico natural gas engine-driven condensing unit, and the institutional sector by 25-ton Carrier engine-driven rooftops. The York Triathlon heat pump showed a good performance at the given conditions, with an average COP of 1.29 in cooling mode and of 1.03 in heating mode. The Trico unit was fully instrumented at NGTC; performance testing will be carried out later in 1996. The Carrier rooftops showed performance levels below those of the manufacturer`s suggested characteristics, although user satisfaction with the comfort provided by the units was high. 7 refs., 9 figs., 3 tabs.

  15. 空气源热泵辅助型太阳能热水系统标准的探讨%Research on Specifications of Air Source Heat Pump Assisted Domestic Solar Water Heating Systems

    Institute of Scientific and Technical Information of China (English)

    徐言生; 何钦波; 陈学锋; 李锡宇

    2013-01-01

    The Specifications of Air Source Heat Pump Assisted Domestic Solar Water Heating Systems have stipulated a certain range of variations on the mean environment temperature and the amount of solar radiation in the coefficient of performance (COP) testing of whole unit. In order to research the influence of the variations on COP, the performance testing was divided into two phases. The test of solar water heating system was performed outdoors. The test of air source heat pump heating was performed in an environmental test chamber whose temperature could be adjusted. The experimental results show that the variations in the mean environment temperature and the amount of solar radiation had a great influence on the COP of air source heat pump assisted domestic solar water heating systems. The variation of the COP of the whole unit was minor with the influence of the mean environment temperature and the amount of solar radiation on the solar water heating system performance. But the maximum change of the COP of the whole unit could reach 40%with the influence of the mean environment temperature on the air source heat pump performance. Hence, the amending advice on the testing methods and conditions of the specifications were presented.%《家用空气源热泵辅助型太阳能热水系统技术条件》中对整机综合制热性能系数(COP)试验的平均环境温度和全天太阳能辐照量给出了一定变化范围,为研究这一变化对整机综合COP的影响,将整机的性能试验分两个阶段进行,其中太阳能热水系统加热段在户外进行,空气源热泵加热段在环境温度可控的环境试验室进行。试验表明在标准规定的变化范围内,平均环境温度的变化及全天辐照量的变化对空气源热泵辅助太阳能热水系统整机综合COP有较大影响,其中因平均环境温度的变化及全天辐照量的变化对太阳能热水系统性能影响而引起整机综合COP

  16. Global design of a reversible air/water heat pump with variable power for the residential sector; Conception globale d'une pompe a chaleur air/eau inversable a puissance variable pour le secteur residentiel

    Energy Technology Data Exchange (ETDEWEB)

    Flach-Malaspina, N.

    2004-10-15

    Variable power is one of the means to improve the seasonal energy efficiency of heat pump space heating systems. The dual compressors technology is energetically efficient and is available in Europe. The main results of this work are: 1 - the identification of the origin of cycling losses in heating and cooling mode of existing mono-compressor air/water systems. The standby consumption of the heat pump is the only element which can efficiently contribute to reduce the energy losses at partial load. 2 - The quantification of the energy gains by adapting the dual compressors technology to a prototype of reference heat pump. 3 - A dynamic model of calculation of the seasonal coefficient of performance has been developed. 4 - The optimization of compressors operation and of the unfreezing system has permitted to increase the seasonal coefficient of performance from 14.7% to 18.6% with respect to the outdoor temperature. To carry out this study, design, experimental and modeling works have been done. The design of a heat pump fitted with two compressors has required the development of a new partial load testing bench. The several experimental and standardized tests have permitted to characterize an existing heat pump and a dual compressor heat pump whatever the operation mode and the outdoor climate. The dynamical model obtained has permitted to optimize the energy efficiency of the system thanks to a better management of the unfreezing system and to a proper regulation of the compressors. Some ways of improvement concern the dimensioning of compressors and the management of exchangers flow rates for an additional improvement of seasonal coefficients of performance. (J.S.)

  17. Ground-water-coupled heat pump for heating the field and for cooling rooms at the Arnheim multi-purpose ``Gelredome`` stadium; Grundwassergekoppelte Waermepumpe fuer die Spielfeldheizung und Raumkuehlung des Mehrzweckstadiums ``Gelredome`` in Arnheim

    Energy Technology Data Exchange (ETDEWEB)

    Bakema, G.; Snijders, A.L. [IF Technology bv, Arnheim (Netherlands)

    1997-12-01

    Some of the things that the Gelredome multi-purpose stadium will be equipped with will be a horizontal draw-out lawn, solar collectors, and a sliding roof. But the nicest piece of technology that the site has to offer has been buried in the ground for several ten thousand years: a ground water aquifer. This layer of sand is conditioned for temporary storage of surplus energy obtained by heating and cooling with the aid of a heat pump. The paper deals with this specific aspect of energy storage. But to begin with, a general overview of the use of heat pumps in the Netherlands is given, especially where they are combined with energy storage. (orig.) [Deutsch] Das Gelredome-Stadium, ein Mehrzweckstadium, wird unter anderem mit einer ausfahrbaren Grasflaeche, mit Sonnenkollektoren und mit einem Schiebedach ausgestattet. Das schoenste Stueckchen Technik verbirgt sich dort jedoch schon seit mehreren zehntausend Jahren unter der Erdoberflaeche: Ein Grundwasserleiter. Diese Sandschicht wird fuer die zeitweilige Speicherung des Energieueberschusses, der beim Heizen und Kuehlen mit einer Waermepumpe zur Verfuegung kommt, eingerichtet werden. Auf diesen spezifischen Fall der Energiespeicherung wird gleich eingegangen. Zuerst aber noch eine allgemeine Uebersicht ueber die Lage in den Niederlanden in bezug auf Waermepumpen und insbesondere, wenn diese mit Energiespeicherung kombiniert wird. (orig.)

  18. A review on opportunities for the development of heat pump drying systems in South Africa

    Directory of Open Access Journals (Sweden)

    Thomas Kivevele

    2014-05-01

    Full Text Available Recently, it has been discovered that heat pump drying is an efficient method of drying for drying industries. Heat pumps deliver more heat during the drying process than the work input to the compressor. Heat pump drying is a more advanced method than the traditional South African industrial and agricultural drying methods, such as direct/indirect sunlight, wood burning, fossil fuel burning, electrical heating and diesel engine heating. Heat pump dryers provide high energy efficiency with controllable temperature, air flow and air humidity and have significant energy-saving potential. In the last decade the market for heat pump systems for water heating and space cooling/heating has grown in South Africa, but the development of heat pumps for industrial and agricultural drying is very slow. As a result of high increases in fossil fuel prices and electricity in South Africa, as well as the problem of CO2 emissions, green energy, energy saving and energy efficiency are imperative. The development of heat pump drying systems in South Africa is an efficient way to solve energy problems in drying applications as this technology is still in its infancy. We review studies on heat pump drying and compare the methods therein with the most common methods of drying in South Africa.

  19. An optimized ground-coupled heat pump system design for northern climate applications

    Energy Technology Data Exchange (ETDEWEB)

    Catan, M.A.; Baxter, V.D.

    1985-01-01

    This paper addresses the question of the performance of a ground coupled heat pump (GCHP) system with a water-source heat pump package designed expressly for such systems operating in a northern climate. The project objective was to minimize the life-cycle cost of a GCHP system by optimizing the design of both the heat pump package and the group coil in concert. In order to achieve this objective, a number of modelling tools were developed to analyze the heat pump's performance and cost, and the ground coil's performance.

  20. Accommodation Mode of Wind Power Based on Water Source Heat Pump Technology%基于水源热泵技术的风电消纳模式

    Institute of Scientific and Technical Information of China (English)

    李群英; 冯利民; 许宇辉; 李春亮; 王绍然

    2012-01-01

    Based on the water source heat pump technology,a novel mode on wind power accommodation is proposed.The principle of this mode is analyzed firstly,its impacts on the improvement of the wind power accommodation,the promotion of energy-saving and emission-reduction,the improvement of city heat supply and the economic enhancement of the electrical generation enterprises are studied.With the proposed mode,the residual heat of the circulating water in the heat-engine plants can be recycled to improve the quality of city heat supply,the stability of the heat supply network and the capacity of wind power accommodation in the power grid,and reduce carbon emission during the process of electric power generation.The economic,social,environmental benefits and its application prospect are verified by the research data.%提出了基于水源热泵技术的风电消纳模式。分析了该模式的原理,研究了其在增加风电消纳、促进节能减排、改善城市供热及提高发电企业经济效益等方面的作用。研究表明,通过该模式,可将火力发电厂冷却循环水中的低品位余热转变为有用热能进行城市供暖,提高城市集中供热的质量和稳定性,同时还能够显著增加电网风电消纳能力,并有利于减少电能生产过程中的污染物排放。分析表明,该模式具有良好的经济、社会与环境效益,具备良好的发展前景。

  1. Performance testing of an air/water heat pump using CO{sub 2} (R744) as refrigerant for the preparation of sanitary hot water in a hospital; Mesures des donnees energetiques d'une pompe a chaleur air/eau au CO{sub 2} (R744) pour preparation d'eau chaude sanitaire dans un hopital

    Energy Technology Data Exchange (ETDEWEB)

    Anstett, P.

    2006-07-01

    This final report prepared for the Swiss Federal Office of Energy (SFOE) describes the monitoring equipment and the results of performance tests made on a prototype heat pump of 60 kW power output used for hot water production at the hospital of Le Locle, Switzerland. The heat pump uses carbon dioxide (R744) as the working fluid and ambient air as the heat source. The heat output and the coefficient of performance for various values of cold water temperature and air temperature have been measured. The practically measured values of heat output and COP showed a low reproducibility and remained far behind the theoretical values given by the manufacturer. Instead of producing hot water at 80 {sup o}C as intended originally the authors recommend to use the heat pump only for preheating the water to 60 {sup o}C.

  2. 空气源热泵在学生公寓的热水改造工程中的应用%Application of Air Source Heat Pump Water Heater to Reconstruction Project of Domestic Hot Water in Student Apartment

    Institute of Scientific and Technical Information of China (English)

    何绪春

    2012-01-01

    The domestic water-heating system with gas-fired boiler of a college apartment in Chongqing was discussed.The reconstruction plans concerning air-source heat pump heating system and solar assisted air-source heat system were processed and discussed respectively after the analysis on daily hot water load.Compared with the original water-heating system,the annual operating costs of solar heating systems would be the lowest.%以重庆某学校采用燃气锅炉房作为热源的洗浴热水加热系统作为研究对象。对热水系统日用热量进行了分析。对原加热系统提出两种改造方案:空气源热泵加热系统、太阳能辅助空气源加热系统,探讨了这两种加热系统的系统流程,与原加热系统的年运行费用进行了比较,太阳能加热系统的年运行费用最低。

  3. 46 CFR 108.471 - Water pump.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Water pump. 108.471 Section 108.471 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS DESIGN AND EQUIPMENT Fire Extinguishing Systems Foam Extinguishing Systems § 108.471 Water pump. Each water pump in a foam...

  4. 涡旋式水源热泵系统性能仿真%Performance Simulation of Scroll Water Source Heat Pump System

    Institute of Scientific and Technical Information of China (English)

    汤志远; 丁国良

    2011-01-01

    为了预测涡旋式水源热泵系统变结构和变工况稳态性能,建立了稳态涡旋式热泵系统仿真模型.其中涡旋式压缩机模型考虑了吸、排气换热对工质流量和排气温度的影响以及流量、排气温度和输入功率三者的耦合关系;通过增加电子膨胀阀开度对蒸发器出口过热度的控制模型,反映了过热度对膨胀阀流量的影响.系统算法综合了顺序模块法和连续迭代法,改善了迭代收敛性,且易于实现部件模型的模块化.与实验结果对比表明:模型预测值与实验值的误差小于4.4%.%To predict the steady performance of scroll water source heat pumps with different configuration and working condition a steady systematic model for scroll water source heat pump is established. In modeling the compressor, the effect of suction heatin on mass flow and the effect of discharge heat exchange on discharge temperature as well as coupling relationship between mas flow, discharge temperature and input power are considered. The effect of the superheat of evaporator on the mass flow through tfc electrical expansion valve (EEV) is reflected by the control model of EEV opening degree on the superheat of evaporator. Successrv Substitution Method and Sequential Modular Method are used in the system simulation, which is 'in favor of modulization an maintainability of components, as well as convergence of algorithm. The deviations between the model predictions and the test dai are less than 4.4%.

  5. Performance of a hybrid chemical/mechanical heat pump

    Science.gov (United States)

    Silvestri, John J.; Scaringe, Robert P.; Grzyll, Lawrence R.

    1990-01-01

    The authors present the design and preliminary results of the performance of a hybrid chemical/mechanical, low-lift (20 C) heat pump. Studies have indicated that this heat pump has several advantages over the traditional single fluid vapor compression (reverse Rankine) heat pump. Included in these benefits are: 1) increased COPc due to the approximation of the cycle to the Lorenz cycle and due to the availability of the heat of solution, along with the heat of vaporization, to provide cooling; and 2) ease of variation in system cooling capacity by changing the fluid composition. The system performance is predicted for a variety of refrigerant-absorbent pairs. Cooling capacity is determined for systems operating with ammonia as the refrigerant and lithium nitrate and sodium thiocyanate as the absorbents and also with water as the refrigerant and magnesium chloride, potassium hydroxide, lithium bromide, sodium hydroxide, and sulfuric acid as the absorbents. Early indications have shown that the systems operating with water as the refrigerant operate at 2-4 times the capacity of the ammonia-refrigerant-based systems. Using existing working fluids in the proposed innovative design, a coefficient-of-performance improvement of 21 percent is possible when compared to the best vapor compression systems analyzed.

  6. Performance of a hybrid chemical/mechanical heat pump

    Science.gov (United States)

    Silvestri, John J.; Scaringe, Robert P.; Grzyll, Lawrence R.

    1990-01-01

    The authors present the design and preliminary results of the performance of a hybrid chemical/mechanical, low-lift (20 C) heat pump. Studies have indicated that this heat pump has several advantages over the traditional single fluid vapor compression (reverse Rankine) heat pump. Included in these benefits are: 1) increased COPc due to the approximation of the cycle to the Lorenz cycle and due to the availability of the heat of solution, along with the heat of vaporization, to provide cooling; and 2) ease of variation in system cooling capacity by changing the fluid composition. The system performance is predicted for a variety of refrigerant-absorbent pairs. Cooling capacity is determined for systems operating with ammonia as the refrigerant and lithium nitrate and sodium thiocyanate as the absorbents and also with water as the refrigerant and magnesium chloride, potassium hydroxide, lithium bromide, sodium hydroxide, and sulfuric acid as the absorbents. Early indications have shown that the systems operating with water as the refrigerant operate at 2-4 times the capacity of the ammonia-refrigerant-based systems. Using existing working fluids in the proposed innovative design, a coefficient-of-performance improvement of 21 percent is possible when compared to the best vapor compression systems analyzed.

  7. Optimization of a ground coupled heat pump

    Energy Technology Data Exchange (ETDEWEB)

    Baxter, V.D.; Catan, M.A.

    1984-01-01

    A cooperative analytical project has optimized a horizontal ground coil heat pump system for the Pittsburgh climate. This is the first step in the exploration of several advanced designs including various ground coil devices and advanced heat pump components. The project made use of new and existing design tools to simulate system performance and determine first cost. The system life cycle cost was minimized while constraining the system to meet the design day cooling load using a function minimizing program. Among the system parameters considered were: air-to-refrigerant frontal area, air-to-refrigerant fin pitch, air-to-refrigerant air flowrate, compressor displacement, liquid-to-refrigerant coil length, liquid-to-refrigerant coil diameter, ground coil fluid flowrate, ground coil length, and ground coil depth.

  8. Affordable Hybrid Heat Pump Clothes Dryer

    Energy Technology Data Exchange (ETDEWEB)

    TeGrotenhuis, Ward E. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Butterfield, Andrew [Jabil, St. Petersburg, FL (United States); Caldwell, Dustin D. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Crook, Alexander [Jabil, St. Petersburg, FL (United States)

    2016-06-30

    This project was successful in demonstrating the feasibility of a step change in residential clothes dryer energy efficiency by demonstrating heat pump technology capable of 50% energy savings over conventional standard-size electric dryers with comparable drying times. A prototype system was designed from off-the-shelf components that can meet the project’s efficiency goals and are affordable. An experimental prototype system was built based on the design that reached 50% energy savings. Improvements have been identified that will reduce drying times of over 60 minutes to reach the goal of 40 minutes. Nevertheless, the prototype represents a step change in efficiency over heat pump dryers recently introduced to the U.S. market, with 30% improvement in energy efficiency at comparable drying times.

  9. Phonon Cooling by an Optomechanical Heat Pump.

    Science.gov (United States)

    Dong, Ying; Bariani, F; Meystre, P

    2015-11-27

    We propose and analyze theoretically a cavity optomechanical analog of a heat pump that uses a polariton fluid to cool mechanical modes coupled to a single precooled phonon mode via external modulation of the substrate of the mechanical resonator. This approach permits us to cool phonon modes of arbitrary frequencies not limited by the cavity-optical field detuning deep into the quantum regime from room temperature.

  10. Heat pump processes induced by laser radiation

    Science.gov (United States)

    Garbuny, M.; Henningsen, T.

    1980-01-01

    A carbon dioxide laser system was constructed for the demonstration of heat pump processes induced by laser radiation. The system consisted of a frequency doubling stage, a gas reaction cell with its vacuum and high purity gas supply system, and provisions to measure the temperature changes by pressure, or alternatively, by density changes. The theoretical considerations for the choice of designs and components are dicussed.

  11. Measured Performance of a Low Temperature Air Source Heat Pump

    Energy Technology Data Exchange (ETDEWEB)

    R.K. Johnson

    2013-09-01

    A 4-ton Low Temperature Heat Pump (LTHP) manufactured by Hallowell International was installed in a residence near New Haven, Connecticut and monitored over two winters of operation. After attending to some significant service issues, the heat pump operated as designed. This report should be considered a review of the dual compressor “boosted heat pump” technology. The Low Temperature Heat Pump system operates with four increasing levels of capacity (heat output) as the outdoor temperature drops.

  12. Fluidized Bed Air-to-Air Heat Pump Evaporator Evaluation.

    Science.gov (United States)

    1983-07-01

    Frost formation of air-to-air heat pump evaporator surfaces reduces unit efficiency and restricts application. The use of a fluidized bed heat...exchanger as an air-to- heat pump evaporator was investigated to determine if frost accumulation could be eliminated. Experimental investigations were...evaluated, with no practical solution being developed. The use of a fluidized bed heat exchanger for air-to-air heat pump evaporators was determined not feasible. (Author)

  13. A New Type of Complex System of Solar Energy Air Source Heat Pump Water Heater%一种新型的太阳能——空气源复合热泵热水器系统

    Institute of Scientific and Technical Information of China (English)

    王军军

    2011-01-01

    基于太阳能热利用技术、空气源热泵热水器理论,介绍了一种将太阳能与空气源相结合的双热源热泵热水器系统。该系统可充分利用太阳能加热生活用热水,辅以空气源热泵来满足太阳辐射照度不足时的用热水需求,同时用太阳能辅助加热来解决低温环境下空气源热泵运行工况恶劣的问题。系统充分利用了低品位的太阳能,保证稳定性,又可提高夏季阴雨天气、过渡季节及冬季太阳能热水器的热水温度,对于节约能源和环境保护具有重要意义。%Based on the technology of solar thermal and the theory of air-source heat pump water heater, a combined water heater system about solar and air source heat pump was introduced. The system Could make full use of solar energy to heat domestic hot water, combined with air-source heat pump to meet the shortage of solar irradiance when the hot water demand, and the auxiliary heating with solar energy to solve the problems of air source heat pump operating conditions in low temperature. The system took full use of the low-grade solar energy, and stability could be assured. And it could improve the temperature of the water in solar water heaters in rainy summers, transition seasons and winters. The system had significance for energy conservation and environmental protection.

  14. Open-cycle vapor compression heat pump

    Science.gov (United States)

    Becker, F. E.; Ruggles, A. E.

    1985-03-01

    Large quantities of low-grade energy in the form of low-pressure steam and low-temperature heat are often discharged to the environment by industry. The practical and economical recovery of energy from these sources is often limited by the number of applications that can directly use low-temperature heat. Thermo Electron has developed an open-cycle steam heat pump system capable of the direct recovery and upgrading of low-grade waste energy. The system compresses low-pressure waste steam (or steam made from sources of low-temperature waste heat) to produce high-pressure steam suitable for use in industrial processes. A prototype system has been developed that is capable of recovering and recompressing up to 10,000 lb/hr of waste steam, while using only 50 percent of the fuel that would be required to produce comparable steam in a boiler.

  15. Environmental Heat Capacity of River Received the Tail Water of Surface Water Resource Heat Pump%基于地表水源热泵尾水排放的江河热环境容量研究

    Institute of Scientific and Technical Information of China (English)

    黄晓武; 刘杰; 孔淑琼; 洪念; 顾晨; 李恺

    2012-01-01

    运用FLUENT软件对重庆市洪崖洞水源热泵系统尾水排入受纳水域的过程进行二维数值模拟,选取FLUENT中非耦合、隐式求解器对模型内的定常流动进行求解,得出受纳水域受水源热泵系统温排水影响后的温度梯度和温升面积.在温排水流量为4 500 m3/h、温差为6℃的条件下,得出受纳水域温升值超过1℃的水域面积约为1 600m2,为模拟江河水域面积的2.0%.选取1℃温升值作为温升带边界控制值,在热泵系统最大负荷工况下,计算得出受纳水域的热环境容量为312.5 (m3·℃)/s,剩余热环境容量为306.25 (m3·℃)/s.根据地表水环境质量标准,该工程温排水量小于受纳水域的热承载力,不会对受纳水域生态环境造成热污染.%Public hydrodynamic FLUENT software was used to make two dimensional numerical simulation on the process of tail water discharged into the received water of water resource heat pump of Hongya Hole in Chongqing, the steady flow process in the model by using uncoupled implicit solvers was studied, and the temperature rising area and temperature grads of the influencing source were obtained. As the flow of thermal discharge was 4 500 m3/h and temperature difference was 6 ℃, it showed that water area was 1 600 m2 if temperature of water rose 1 t, which was 2.0% of simulation river acreage area. Boundary value control of temperature rising area with one degree was intercalated, in the condition of mostly polluted, environment heat capacity was 312.5 (m3·℃)/s, furthermore the residual environmental heat capacity was 306.25 (m3·℃)/s. According to water environment quality standard, capacity of thermal discharge was under the received water, and there was no thermal pollution to ecological environment of the received water.

  16. Incorporating the Variability of Wind Power with Electric Heat Pumps

    Directory of Open Access Journals (Sweden)

    Hongyu Long

    2011-10-01

    Full Text Available With the mass introduction of wind power in Northern China, wind power variability has appeared. In this article, both existing electric heat pumps (EHPs and coal-fired combined heat and power (CHP facilities, which are generally equipped with extraction-condensing steam turbines coupled with district heating for space heating purposes, are proposed to incorporate the variability of wind power equivalently. The authors’ proposal arises from the facts that: (1 EHPs can provide space heating in the domestic sector with little thermal comfort change (e.g., energy carriers for space heating purposes can be switched from heating water to electricity; (2 coal-fired CHP units in Northern China can usually generate more electrical power corresponding to a shaved thermal power production. Thus, it is suggested that heating water from CHP units be shaved when the wind generation is low due to the variability of wind power, so as to enable more electrical power production and compensate for the corresponding insufficient wind generation. Following this, in the future and for some space heating loads at appropriate distances, electricity used as energy carrier should be converted by electric heat pumps for space heating. Thus, more electricity consumption will be achieved so as to avoid wasting wind power when the wind generation it is high. A numerical simulation is performed in order to illustrate the authors’ proposal. It is shown that the impact of variability of wind generation can be equivalently reduced to a great extent, which enable more wind power integration instead of curtailment and potential energy conservation. Moreover, in contrast to before, both the thermal and electrical power of coal-fired CHP units are no longer constants. In addition, the ratio of electrical to thermal power of CHP units is no longer constant either, and results in less energy consumption compared with fixed ratio. Finally, electricity consumed by end users’ EHPs

  17. Earliest Deadline Control of a Group of Heat Pumps with a Single Energy Source

    Directory of Open Access Journals (Sweden)

    Jiří Fink

    2016-07-01

    Full Text Available In this paper, we develop and investigate the optimal control of a group of 104 heat pumps and a central Combined Heat and Power unit (CHP. The heat pumps supply space heating and domestic hot water to households. Each house has a buffer for domestic hot water and a floor heating system for space heating. Electricity for the heat pumps is generated by a central CHP unit, which also provides thermal energy to a district heating system. The paper reviews recent smart grid control approaches for central and distributed levels. An online algorithm is described based on the earliest deadline first theory that can be used on the aggregator level to control the CHP and to give signals to the heat pump controllers if they should start or should wait. The central controller requires only a limited amount of privacy-insensitive information from the heat pump controllers about their deadlines, which the heat pump controllers calculate for themselves by model predictions. In this way, a robust heat pump and CHP control is obtained, which is able to minimize energy demand and results in the desired thermal comfort for the households. The simulations demonstrate fast computation times due to minor computational and communication overheads.

  18. Research on ground heat exchanger of Ground Source Heat Pump technique

    Institute of Scientific and Technical Information of China (English)

    LIU Dong-sheng; SUN You-hong; GAO Ke; WU Xiao-hang

    2004-01-01

    Ground Source Heat Pump technique and its operating principle are described in this paper. Ground heat exchanger is the key technique of ground source heat pump and its pattems are discussed. Software is helpful to design ground heat exchanger. A project of Chinese Ground Source Heat Pump is introduced and its market is more and more extensive.

  19. The use of an absorption heat pump by a thermal bathing establishment

    Energy Technology Data Exchange (ETDEWEB)

    Lazzarin, R.M.; Longo, G. (Padua Univ. (Italy)); Piccininni, F. (Bari Univ. (Italy). Ist. di Fisica Tecnica)

    1992-07-01

    An energy saving plant was realized by a thermal bathing establishment. The plant is composed of a three fluid plate heat exchanger and an absorption heat pump between the source preheated water and the discharged one. During the cold winter the establishment is maintained at a temperature of 5[sup o]C. The absorption heat pump uses the thermal water as the cold source. (Author).

  20. Use of buried collector heat pumps in space heating and cooling; Utilisation en chauffage et en refraichissement des thermopompes a capteurs enterres

    Energy Technology Data Exchange (ETDEWEB)

    Bernier, J. [Societe SYREC, 22 - Dinan (France)

    1997-12-31

    This paper presents a comparative evaluation of the seasonal thermal performances of the different types of heat pumps with buried collectors: ground/ground type, water-glycol water type, and ground/water type. The different systems are also compared with respect to their adaptation to reversibility. A heat pump system for sanitary hot water production is also presented. (J.S.)

  1. Controller of heat pump water heater based on WinCE%基于WinCE的热泵热水机控制器

    Institute of Scientific and Technical Information of China (English)

    吴宇明; 姜周曙; 黄国辉; 徐平

    2011-01-01

    针对目前市场上大型热泵热水机控制器价格高、硬件模块多及远程监控性能不足等问题,研制了一种基于ARM9和WinCE操作系统的热泵热水机控制器.以S3C2410A和STM32F103VC为硬件平台核心,设计了人机交互单元和数据采集控制单元;以嵌入式Windows CE 5.0为操作系统,利用EVC开发应用软件,并重点阐述了系统结构、各主要模块的硬件电路及工作原理和应用程序的设计方法及编程要点.实际应用结果表明,该控制系统操作简便、功能完善、性能稳定,控制精度达到了使用要求.%Aiming at high cost,more hardware modules and the poor performance of remote monitoring of large heat pump water heater controller in the current market,a new heat pump water heater controller based on ARM9 and WinCE operating system was developed. Human-computer interaction,data acquisition and control unit were designed,taking S3C2410A and STM32F103VC as the cores of hardware platform. Application software was developed using EVC under Windows CE 5.0 embedded operating system. And the overall structure of the controller, the working principle of main modules and the method of applications design and programming essentials were elaborated. Practical application result indicates that the control system is easy for operation,has perfect function and stable in performance,and the control precision meets the requirements of needs.

  2. Ground as a possible heat pump source

    Energy Technology Data Exchange (ETDEWEB)

    Lazzarin, R. [Padova Univ. (Germany). Dipt. di Tecnica e Gestione die Istemi Industriali

    2001-06-01

    Heat pumps are devices that can increase the thermal level of heat taken from an available source. Their performances are usually very sensible to the temperatures. This is the reason why sources different from the outside air are welcome, since that source is thermally unfavourable. The ground is a possible very favourable source: temperature variations are damped in the ground so much the more deeper one descends. The variations are also delayed, so that in the coldest period one can find equality very good thermal levels. The two main used systems are: horizontal tubes at a depth between 0.8 and 1.5m and vertical tubes. This last technology has gained an increasing popularity with depths which are sometimes deeper than 100m. It interests a large volume of ground with a comparatively small surface area. It is a technology already widespread in Switzerland (where more than 15.000 ground heat pumps were installed in these years), Germany and Austria. It could be a very favourable technology also in Italy and other mediterranean countries both for the presence of good thermal levels underground with excellent characteristics of heat exchange and for the possible use of the ground as a suitable summer thermal sink. (orig.)

  3. Production of gerbera throughout a year by utilizing water heat accumulating heat pumps. Practical application of control of culture medium temperature by rock wool cultivation, and technology to produce gerbera throughout a year; Mizu chikunetsushiki heat pump wo riyoshite gabera wo shunen seisan. Rokku uruko ni yoru baichion seigyo to gabera no shunen seisan gijutsu no jitsuyoka

    Energy Technology Data Exchange (ETDEWEB)

    Aoki, M. [Kansai Electric Power Co. Inc., Osaka (Japan)

    1999-03-10

    In order to utilize electric power more effectively in agriculture, technology to produce gerbera throughout a year by using rock wool cultivation has been established, by which culture medium temperature is cooled (heated) by using heat pumps. Once implanted, gerbera can provide flowers for two years, and demand for its cut flowers is increasing year after year. However, because high temperature in summer can create deformed flowers, reducing the rate of acceptable flower production, cut flower production is suspended during summer at the present. Therefore, nighttime electric power was utilized to accumulate cold (warm) water in a heat accumulation tank, circulate the water, and control the rock wool culture medium temperature to 20 to 25 degrees C which is suitable for growth of the plant. This system has made it possible to reduce greenhouse warming cost in winter. A non-control area had the average culture medium temperature vary to 30 degrees C or higher in summer and 15 degrees C in winter, while the control area maintained the temperature at 22 {+-} 1 degrees C both in summer and winter. The control area created not too great difference in flow quality as flower diameter and weight as compared to that in the non-control area, but had better flower stalk length with less deformed flower production, enhanced the acceptable product rate, and attained annual yield as great as 1.4 times. The assignment to the system is cost reduction. (NEDO)

  4. Crawl space assisted heat pump. [using stored ground heat

    Science.gov (United States)

    Ternes, M. P.

    1980-01-01

    A variety of experiments and simulations, currently being designed or underway, to determine the feasibility of conditioning the source air of an air to air heat pump using stored ground heat or cool to produce higher seasonal COP's and net energy savings are discussed. The ground would condition ambient air as it is drawn through the crawl space of a house. Tests designed to evaluate the feasibility of the concept, to determine the amount of heat or cool available from the ground, to study the effect of the system on the heating and cooling loads of the house, to study possible mechanisms which could enhance heat flow through the ground, and to determine if diurnal temperature swings are necessary to achieve successful system performance are described.

  5. Simulation of Hybrid Photovoltaic Solar Assisted Loop Heat Pipe/Heat Pump System

    Directory of Open Access Journals (Sweden)

    Nannan Dai

    2017-02-01

    Full Text Available A hybrid photovoltaic solar assisted loop heat pipe/heat pump (PV-SALHP/HP water heater system has been developed and numerically studied. The system is the combination of loop heat pipe (LHP mode and heat pump (HP mode, and the two modes can be run separately or compositely according to the weather conditions. The performances of independent heat pump (HP mode and hybrid loop heat pipe/heat pump (LHP/HP mode were simulated and compared. Simulation results showed that on typical sunny days in spring or autumn, using LHP/HP mode could save 40.6% power consumption than HP mode. In addition, the optimal switchover from LHP mode to HP mode was analyzed in different weather conditions for energy saving and the all-year round operating performances of the system were also simulated. The simulation results showed that hybrid LHP/HP mode should be utilized to save electricity on sunny days from March to November and the system can rely on LHP mode alone without any power consumption in July and August. When solar radiation and ambient temperature are low in winter, HP mode should be used

  6. Data from Sustainability Base Characterizing Hot Water Pump Differential Pressure Spikes for ACCEPT

    Data.gov (United States)

    National Aeronautics and Space Administration — During the heating season in Sustainability Base, a critical alarm associated with a hot water pump circulating heating water for the radiative system which...

  7. Natural refrigerants. Future heat pumps for district heating; Naturliga koeldmedier. Framtida vaermepumpar foer fjaerrvaerme

    Energy Technology Data Exchange (ETDEWEB)

    Ingvarsson, Paul; Steen Ronnermark, Ingela [Fortum Teknik och Miljoe AB, Stockholm (Sweden); Eriksson, Marcus [Chalmers Univ. of Technology, Goeteborg (Sweden). Dept. of Chemical Engineering and Environmental Science

    2004-01-01

    International work on refrigerants is aiming at phasing out HFC. The solution might be natural refrigerants. Within 15-20 years, when present heat pumps for district heating in Sweden are likely not in service any longer, it might still be good economy to install new heat pumps since only the machines need to be replaced. This report describes the possibilities to use natural refrigerants. A first screening resulted in further study on some hydrocarbons, ammonia and carbon dioxide. Water was considered to require too large volumes. In present plants it is practically not possible to use any natural refrigerants, partly because the compressors are not adapted. In new plants the situation is different. Today it is technically possible to install new heat pumps in the studied size, 15 MW{sub th}, using ammonia or hydrocarbons as refrigerant. But likely it is very difficult to get permits from authorities since the refrigerants are toxic or highly flammable. There is substantial international research on using carbon dioxide, and this refrigerant is also used in some applications. Carbon dioxide is used at high pressure and in a trans-critical process. Surprisingly, it turned out that one compressor manufacturer considers it possible to supply a heat pump for district heating within 5 years. This development has taken place in Russia, mainly for domestic use. Thus, within 15 to 20 years there will probably exist a technique where carbon dioxide is used. However, more development is needed. Additionally, low district heating return temperatures are also needed to get an acceptable COP. The investment cost for a heat pump installation is considered to be approx. 30 % higher when using ammonia or propane compared to using R134a. When using carbon dioxide there is in the longer run potential to get lower cost than for R134a. The COPs are almost identical if the systems are properly designed. In the carbon dioxide case the COP is somewhat lower, but has a potential for

  8. The Seasonal Coefficient of Energy Transformation for Real Heat Pump

    Directory of Open Access Journals (Sweden)

    Rolandas Jonynas

    2011-04-01

    Full Text Available The resort of low potential energy for buildings heating and preparation of domestic hot water (DHW are discussed in this paper. Real heat pump system, which was designed and mounted for individual house heating and DHW preparation, was analyzed. The purpose of this research was to explore the seasonal factor of performance for heat pump. Manufacturer and salespeople claim that the coefficient of performance (COP for their offered equipment is 4.5 or even higher. They also calculate the energy transformation through the entire season referring to it. Actually, it is likely that the COP cannot be used when calculating the seasonal energy transformation in reality. Electricity that is seasonally consumed and the heat that is produced in all the period should be analyzed in this context. The results of this exploration show that the real seasonal factor of performance is 3.02. With reference to experience of financial support for that type of heating systems in various European countries, there is a great necessity to create similar support schemes in Lithuania. The methodology of assessing the seasonal heat pump’s factors for performance also should be prepared in Lithuania.Article in Lithuanian

  9. Optimized ground-coupled heat pump system design for northern climate applications. [Including ground coil

    Energy Technology Data Exchange (ETDEWEB)

    Catan, M.A.; Baxter, V.D.

    1985-01-01

    This paper addresses the question of the performance of a ground coupled heat pump (GCHP) system with a water - source heat pump package designed expressly for such systems operating in a northern climate. The project objective was to minimize the life-cycle cost of a GCHP system by optimizing the design of both the heat pump package and the ground coil in concert. In order to achieve this objective, a number of modelling tools were developed or modified to analyze the heat pump's performance and cost and the ground coil's performance. The life-cycle cost of a GCHP system (water-source heat pump with a horizontal ground coil) for an 1800 ft/sup 2/ (167 m/sup 2/) house in Pittsburgh, PA, was minimized over a 7 year economic life. Simple payback for the optimized GCHP system, relative to conventional air-source heat pumps, was under 3 years. The water-source heat pump package resulting from this optimization is calculated to cost 21% more than its conventional counterpart with a heating coefficient of performance (COP) about 20% higher, and a cooling COP about 23% higher. In the GCHP system modeled, its annual energy savings are predicted to be about 11% compared to a system designed around the conventional heat pump while having about the same installation cost. The major conclusion of this study is - GCHP system performance improvement can be attained by improving the water-source heat pump package at less cost than by buying more ground coil. The following conclusions were drawn from the steady-state performance optimization results: (1) By adding about $100.00 to the manufacturer's cost off construction, both the heating and cooling COPs can be improved by 20% or more. (2) Cooling COP need not be sacrificed for the sake of heating performance and vice versa. 13 refs., 11 figs., 12 tabs.

  10. Automation of a water pumping station

    OpenAIRE

    Mesec, Rožle

    2014-01-01

    In the thesis we displayed an automation of an industrial facility on an example of a water pumping station. We described the structure of a typical automated system and presented it's key components. We designed a water pumping station with three main components – a water pump, a reservoir and a drain. The proposed water pumping station could be used for suplying water to a small settlement, in case the settlement had access to a water source with adequate capacity in it's vicinity. As part ...

  11. Cold Climate Heat Pumps Using Tandem Compressors

    Energy Technology Data Exchange (ETDEWEB)

    Shen, Bo [ORNL; Abdelaziz, Omar [ORNL; Rice, C Keith [ORNL; Baxter, Van D [ORNL

    2016-01-01

    In cold climate zones, e.g. ASHRAE climate regions IV and V, conventional electric air-source heat pumps (ASHP) do not work well, due to high compressor discharge temperatures, large pressure ratios and inadequate heating capacities at low ambient temperatures. Consequently, significant use of auxiliary strip heating is required to meet the building heating load. We introduce innovative ASHP technologies as part of continuing efforts to eliminate auxiliary strip heat use and maximize heating COP with acceptable cost-effectiveness and reliability. These innovative ASHP were developed using tandem compressors, which are capable of augmenting heating capacity at low temperatures and maintain superior part-load operation efficiency at moderate temperatures. Two options of tandem compressors were studied; the first employs two identical, single-speed compressors, and the second employs two identical, vapor-injection compressors. The investigations were based on system modeling and laboratory evaluation. Both designs have successfully met the performance criteria. Laboratory evaluation showed that the tandem, single-speed compressor ASHP system is able to achieve heating COP = 4.2 at 47 F (8.3 C), COP = 2.9 at 17 F (-8.3 C), and 76% rated capacity and COP = 1.9 at -13 F (-25 C). This yields a HSPF = 11.0 (per AHRI 210/240). The tandem, vapor-injection ASHP is able to reach heating COP = 4.4 at 47 F, COP = 3.1 at 17 F, and 88% rated capacity and COP = 2.0 at -13 F. This yields a HSPF = 12.0. The system modeling and further laboratory evaluation are presented in the paper.

  12. Noise abatement in air-water heat pump systems. Basic considerations, guidelines for practice; Laermreduktion bei Luft/Wasser-Waermepumpenanlagen. Grundlagen und Massnahmen

    Energy Technology Data Exchange (ETDEWEB)

    Graf, H.R.

    2002-07-01

    With increasing numbers of installations of air/water heat pumps the issue of noise emissions is becoming more of a concern. In reaction to this situation, the company Sulzer Innotec has developed these guidelines by order of the Swiss Federal Office of Energy. Typically, more than 90% of the noise emitted outdoors is produced by the fan. Due to the strong tonal components, the noise emitted is substantially more annoying than a reference broadband noise of the same intensity. For further noise reduction mainly the fan noise must be addressed. Despite the dominance of fan noise, other noise sources must not be neglected. The most promising countermeasures are: Reduction of fan noise by (i) low blade tip speed (prerequisite is a pressure drop in the air channels including the evaporator as low as possible), (ii) improvement of flow geometry in the vicinity of the fan, (iii) insulation of air ducts with acoustic foam (thickness 50 mm or more), (iv) elbows in the air duct line for sound dissipation. Reduction of compressor noise by (i) a highly effective acoustic enclosure, (ii) vibration insulation of structure-borne noise by elastic mounts, (iii) decoupling of refrigerant pipes. (author)

  13. Theoretical study of heat pump system using CO2/dimethylether as refrigerant

    Directory of Open Access Journals (Sweden)

    Fan Xiao-Wei

    2013-01-01

    Full Text Available Nowadays, HCFC22 is widely used in heat pump systems in China, which should be phased out in the future. Thus, eco-friendly mixture CO2/dimethylether is proposed to replace HCFC22. Compared with pure CO2 and pure dimethylether, the mixture can reduce the heat rejection pressure, and suppress the flammability and explosivity of pure dimethylether. According to the Chinese National Standards on heat pump water heater and space heating system, performances of the subcritical heat pump system are discussed and compared with those of the HCFC22 system. It can be concluded that CO2 /dimethylether mixture works efficiently as a refrigerant for heat pumps with a large heat-sink temperature rise. When mass fraction of dimethylether is increased, the heat rejection pressure is reduced. Under the nominal working condition, there is an optimal mixture mass fraction of 28/72 of CO2/dimethylether for water heater application under conventional condensation pressure, 3/97 for space heating application. For water heater application, both the heating coefficient of performance and volumetric heating capacity increase by 17.90% and 2.74%, respectively, compared with those of HCFC22 systems. For space heating application, the heating coefficient of performance increases by 8.44% while volumetric heating capacity decreases by 34.76%, compared with those of HCFC22 systems. As the superheat degree increases, both the heating coefficient of performance and volumetric heating capacity tend to decrease.

  14. Performance evaluation of heat pump dryer.

    Science.gov (United States)

    Pal, U S; Khan, M K

    2010-03-01

    A batch type heat pump assisted dehumidified air dryer was developed successfully with a medium range of temperatures (30-41°C) for safe drying of heat sensitive crops. Dehumidification system of the developed heat pump dryer (HPD) maintained the relative humidity (RH) of air entering the drying chamber below 40%. The inlet drying air temperature decreased during early hours of drying followed by rapid rise between the 2nd and 10th h, after which the temperature was almost stable. The RH of inlet and exhaust drying air increased initially and decreased subsequently with drying time as product became drier. The HPD was found to have a specific moisture extraction rate between 0.55 and 1.10 kg/kWh. Energy consumption for HPD for 24 h of operation was found less (4.48-5.05 kWh) than the hot air dryer (5.65-9.6 kWh) while operating under different drying conditions. Better quality dried sweet pepper (Capsicum annuum L.) was obtained in HPD owing to lower drying air temperature.

  15. Compact interior heat exchangers for CO{sub 2} mobile heat pumping systems

    Energy Technology Data Exchange (ETDEWEB)

    Hafner, Armin

    2003-07-01

    The natural refrigerant carbon dioxide (CO{sub 2}) offers new possibilities for design of flexible, efficient and environmentally safe mobile heat pumping systems. As high-efficient car engines with less waste heat are developed, extra heating of the passenger compartment is needed in the cold season. A reversible transcritical CO{sub 2} system with gliding temperature heat rejection can give high air delivery temperature which results in rapid heating of the passenger compartment and rapid defogging or defrosting of windows. When operated in cooling mode, the efficiency of transcritical CO{sub 2} systems is higher compared to common (HFC) air conditioning systems, at most dominant operating conditions. Several issues were identified for the design of compact interior heat exchangers for automotive reversible CO{sub 2} heat pumping systems. Among theses issues are: (1) Refrigerant flow distribution, (2) Heat exchanger fluid flow circuiting, (3) Air temperature uniformity downstream of the heat exchanger, (4) Minimization of temperature approach, (5) Windshield flash fogging due to retained water inside the heat exchanger, (6) Internal beat conduction in heating mode operation, and (7) Refrigerant side pressure drop In order to provide a basis for understanding these issues, the author developed a calculation model and set up a test facility and investigated different prototype heat exchangers experimentally.

  16. Energy Saving and Benefit Analysis of Water Cooled Heat Pump Energy Recovery System%水冷热泵机组冷热回收系统的节能效益分析

    Institute of Scientific and Technical Information of China (English)

    袁莉莉

    2013-01-01

    本文结合华南地区的温泉度假区实际案例,针对水冷热泵机组冷热回收系统应用,详细介绍其系统设计、运行策略、实际运行数据分析、全年能耗模拟与节能效果分析等,充分证明了该系统的节能效果与经济效益。同时指出,针对酒店行业,水冷热泵机组非常适合在制冷同时回收冷凝器热量,用于免费制取生活热水,节能效益显著。%Combined with the actual case of hot spring resort in south area, aimed at the water cooled heat pump energy recovery system, the system design, operation strategy, real operating data record, whole year energy simulation and energy saving analysis were introduced. The energy saving effect and economic benefits were demostrated. Meanwhile, it is pointed out that in hotel application the condensing heat of heat pumps is very suitable to be recovered to heat domestic hot water while heat pumps are running for cooling, and the energy saving would be remarkable.

  17. Heat pumping with optically driven excitons

    CERN Document Server

    Gauger, Erik M

    2010-01-01

    We present a theoretical study showing that an optically driven excitonic two-level system in a solid state environment acts as a heat pump by means of repeated phonon emission or absorption events. We derive a master equation for the combined phonon bath and two-level system dynamics and analyze the direction and rate of energy transfer as a function of the externally accessible driving parameters. We discover that if the driving laser is detuned from the exciton transition, cooling the phonon environment becomes possible.

  18. Chemical dehumidification and heat recovery: Open-cycle heat pump

    Energy Technology Data Exchange (ETDEWEB)

    Lazzarin, R.; Longo, G.A.; Piccininni, F. (Padua Univ. (Italy). Ist. di Fisica Tecnica)

    1992-02-01

    This article examines an open-cycle heat pump based on a stacked column working with an absorbing solution. The column treats both the expelled air and the fumes generated by the combustion of the methane feeding the solution regenerator. The system is quite easy: it consists of a stacked column, a regenerator with its condenser and four heat exchangers. A simulation - based on a 12kW charge with a 1000 kg/h air exchange - proved that it is possible to obtain an REP higher than 1.5.

  19. 空气能热泵热水机不锈钢内胆焊接工艺优化研究%Optimization of Stainless Steel Tank Welding Procedure in Air-source Heat Pump Water Heater

    Institute of Scientific and Technical Information of China (English)

    刘树清; 余文鹏

    2015-01-01

    The stainless steel tank in air-source heat pump water heater was an container which bear pressure and heat. It is the key component of the air-source heat pump water heater and suffered sever environment at working condition. Welding joint corrosion is the Achilles' heel of stainless tank service life at existing welding procedure. This condition restricted air-source heat pump water heater putting into use and popularize widely. Optimization of stainless steel tank welding procedure in air-source heat pump water heater has been applied several aspect and enhance the service life obviously.%空气能热泵热水器保温水箱的不锈钢内胆是一个承压承热的容器,是热水机产品的关键构件,其工作环境较为恶劣。在现有的焊接工艺条件下,不锈钢内胆的各个焊缝处的腐蚀失效是整个水箱寿命的短板,严重影响了空气能热泵热水机这种新型的节能减排产品的使用和发展。因此对空气能热泵热水机的焊接工艺作了几个方面的优化调整,使得不锈钢内胆的使用寿命得到了较大幅度的提高,取得了良好的效果。

  20. A comparison of the heat and mechanical energy of a heat-pump wind turbine system

    Energy Technology Data Exchange (ETDEWEB)

    Aybek, A.; Arslan, S.; Yildiz, E.; Atik, K. [University of Kahramanmaras (Turkey). Dept. of Agricultural Machinery

    2000-07-01

    While a variety of applications of wind energy have been studied in Turkey, no significant efforts have been made to utilize heat pumps for heat generation. The use of heat pumps in wind energy systems is worth considering because of the high efficiency of heat production. In this study, a directly coupled wind turbine-heat pump system was designed, constructed, and tested. Measurements determined the mechanical energy of the rotors of the wind turbine and the heat energy generated by the heat pump driven by the rotor shaft. Based on the comparisons between the power generated by the heat pump and the power of the Savonius rotors, it was found that the heat energy gained by the heat pump was four times greater than the mechanical energy obtained from the turbine. It was suggested that heat pumps could be efficiently used in wind energy systems. (Author)

  1. Feasibility of a complex compound heat pump

    Science.gov (United States)

    Rockenfeller, Uwe

    1987-07-01

    A feasibility study is described of a double effect gas fired heat pump using ammoniated solid vapor complex compounds as the working media. The cycle takes advantage of the coordinative characteristics of complex compound ligand bonds resulting in large coordination spheres with only one degree of freedom. The cycle has high efficiency, no moving parts, and minimum electrical parasitic requirements. Fluid properties of candidate materials were measured with respect to vapor pressure equilibria, coordination properties and thermal stability. Preliminary reaction rate measurements were performed in adsorption and desorption processes. A computer model of double effect cycle was developed in order to predict the operating performance of the candidate complex compound media. The computer model was used to determine preliminary heat balances and coefficients of performance.

  2. Wind power integration with heat pumps, heat storages, and electric vehicles - Energy systems analysis and modelling

    Energy Technology Data Exchange (ETDEWEB)

    Hedegaard, K.

    2013-09-15

    This PhD investigates to which extent heat pumps, heat storages, and electric vehicles can support the integration of wind power. Considering the gaps in existing research, the main focus is put on individual heat pumps in the residential sector (one-family houses) and the possibilities for flexible operation, using the heat storage options available. Several energy systems analyses are performed using the energy system models, Balmorel, developed at the former TSO, ElkraftSystem, and, EnergyPLAN, developed at Aalborg University. The Danish energy system towards 2030, with wind power penetrations of up to 60 %, is used as a case study in most of the analyses. Both models have been developed further, resulting in an improved representation of individual heat pumps and heat storages. An extensive model add-on for Balmorel renders it possible to optimise investment and operation of individual heat pumps and different types of heat storages, in integration with the energy system. Total costs of the energy system are minimised in the optimisation. The add-on incorporates thermal building dynamics and covers various different heat storage options: intelligent heat storage in the building structure for houses with radiator heating and floor heating, respectively, heat accumulation tanks on the space heating circuit, as well as hot water tanks. In EnergyPLAN, some of the heat storage options have been modelled in a technical optimisation that minimises fuel consumption of the energy system and utilises as much wind power as possible. The energy systems analyses reveal that in terms of supporting wind power integration, the installation of individual heat pumps is an important step, while adding heat storages to the heat pumps is less influential. When equipping the heat pumps with heat storages, only moderate system benefits can be gained. Hereof, the main system benefit is that the need for peak/reserve capacity investments can be reduced through peak load shaving; in

  3. Current status of the problem of heat pumps and refrigerating devices

    Science.gov (United States)

    Vasiliev, L. L.

    2010-09-01

    In connection with the limited energy reserves in the Republic of Belarus, it is expedient to use sorption heat pumps and refrigerators in heating and refrigeration supply systems. Such heat engines possess a unique capability of utilizing the heat of low-temperature energy sources: water ponds, groundwater, and waste water and steam in combination with traditional heaters of rooms (boilers, furnaces, etc.). Adsorption reversible heat pumps developed at the A. V. Luikov Heat and Mass Transfer Institute of the National Academy of Sciences of Belarus make it possible to obtain 20 to 30 kW/m3 of thermal energy and up to 5 kW/m3 of cold. Such heat pumps save up to 15-20% of primary energy (fuel) for production of electricity, heat, and cold.

  4. Experimental Investigations of Heat Pump for Domestic and Light Commercial Market.

    Directory of Open Access Journals (Sweden)

    Mr. Mohite Sachin Kumar

    2012-09-01

    Full Text Available Heat pumps are very efficient heating and cooling systems and can significantly reduce your energy costs. The demand for air conditioning, water heating and potable water cooling, in domestic and light commercial markets is increasing rapidly. Concern for the environ¬ment and increasing price of energy forcing us to review conventional practices and develop novel alternatives. It is a challenge to develop new systems which use environment friendly refrigerants, while, ensuring low initial and operating costs.This article presents heat pump for domestic and light commercial markets which Demonstrates several advantages. Performance of a 1 TR heat pump capable of catering to air conditioning, heating tap water and cooling potable water is indicated and shows that initial and operating cost can be reduced substantially and simultaneously.

  5. Experimental study of the dynamic behaviour of non-azeotropic binary mixtures in heat pumps

    Energy Technology Data Exchange (ETDEWEB)

    Sami, S.M.; Comeau, M.A. (Moncton Univ., NB (CA). School of Engineering)

    1991-01-01

    The dynamic behaviour characteristics of some non-azeotropic refrigerant binary mixtures have been experimentally studied at various concentrations. The study was performed on a water/air heat pump during the heating mode under start-up conditions. The results presented in this study showed that the state of the non-azeotropic refrigerant mixture and its composition and concentration have a significant effect on the heat pump performance during start-up. In addition, the study demonstrated that non-azeotropic refrigerant mixtures could be potential CFC substitutes in heat pump applications. (author).

  6. Solar assisted heat pump on air collectors: A simulation tool

    Energy Technology Data Exchange (ETDEWEB)

    Karagiorgas, Michalis; Galatis, Kostas; Tsagouri, Manolis [Department of Mechanical Engineering Educators, ASPETE, N. Iraklio, GR 14121 (Greece); Tsoutsos, Theocharis [Environmental Engineering Dept., Technical University of Crete, Technical University Campus, GR 73100, Chania (Greece); Botzios-Valaskakis, Aristotelis [Centre for Renewable Energy Sources (CRES), 19th km Marathon Ave., GR 19001, Pikermi (Greece)

    2010-01-15

    The heating system of the bioclimatic building of the Greek National Centre for Renewable Energy Sources (CRES) comprises two heating plants: the first one includes an air source heat pump, Solar Air Collectors (SACs) and a heat distribution system (comprising a fan coil unit network); the second one is, mainly, a geothermal heat pump unit to cover the ground floor thermal needs. The SAC configuration as well as the fraction of the building heating load covered by the heating plant are assessed in two operation modes; the direct (hot air from the collectors is supplied directly to the heated space) and the indirect mode (warm air from the SAC or its mixture with ambient air is not supplied directly to the heated space but indirectly into the evaporator of the air source heat pump). The technique of the indirect mode of heating aims at maximizing the efficiency of the SAC, saving electrical power consumed by the compressor of the heat pump, and therefore, at optimizing the coefficient of performance (COP) of the heat pump due to the increased intake of ambient thermal energy by means of the SAC. Results are given for three research objectives: assessment of the heat pump efficiency whether in direct or indirect heating mode; Assessment of the overall heating plant efficiency on a daily or hourly basis; Assessment of the credibility of the suggested simulation model TSAGAIR by comparing its results with the TRNSYS ones. (author)

  7. An aeroacoustically driven thermoacoustic heat pump.

    Science.gov (United States)

    Slaton, W V; Zeegers, J C H

    2005-06-01

    The mean flow of gas in a pipe past a cavity can excite the resonant acoustic modes of the cavity--much like blowing across the top of a bottle. The periodic shedding of vortices from the leading edge of the mouth of the cavity feeds energy into the acoustic modes which, in turn, affect the shedding of the next vortex. This so-called aeroacoustic whistle can excite very high amplitude acoustic standing waves within a cavity defined by coaxial side branches closed at their ends. The amplitude of these standing waves can easily be 20% of the ambient pressure at optimal gas flow rates and ambient pressures within the main pipe. A standing wave thermoacoustic heat pump is a device which utilizes the in-phase pressure and displacement oscillations to pump heat across a porous medium thereby establishing, or maintaining, a temperature gradient. Experimental results of a combined system of aeroacoustic sound source and a simple thermoacoustic stack will be presented.

  8. Energy performance and economic evaluation of heat pump/organic rankine cycle system with sensible thermal storage

    DEFF Research Database (Denmark)

    Carmo, Carolina; Dumont, Olivier; Nielsen, Mads Pagh

    2016-01-01

    -life conditions knowledge, the paper considers two different sensible energy storage (TES) configurations for the reversible heat pump/organic Rankine cycle (HP/ORC) system: a buffer tank for both space heating and domestic hot water and a hot water storage tank used exclusively for domestic hot water...... that consists of a ground-source heat pump with possibility of reversing operation as an ORC power cycle combined with solar heating in a single-family building is introduced. The ORC mode enables the use of solar energy in periods of no heat energy demand and reverses the heat pump cycle to supply electrical...

  9. Experimental results and model calculations of a hybrid adsorption-compression heat pump based on a roots compressor and silica gel-water sorption

    OpenAIRE

    van der Pal, Michel; De Boer, Robert; Wemmers, Anton; Smeding, Simon; Veldhuis, Jakobert; Lycklama A Nijeholt, Jan-Aiso

    2013-01-01

    Part of: Thermally driven heat pumps for heating and cooling. – Ed.: Annett Kühn – Berlin: Universitätsverlag der TU Berlin, 2013 ISBN 978-3-7983-2686-6 (print) ISBN 978-3-7983-2596-8 (online) urn:nbn:de:kobv:83-opus4-39458 [http://nbn-resolving.de/urn:nbn:de:kobv:83-opus4-39458] Thermally driven sorption systems can provide significant energy savings, especially in industrial applications. The driving temperature for operation of such systems limits the operatin...

  10. Climate Adaptivity and Field Test of the Space Heating Used Air-Source Transcritical CO2 Heat Pump

    Science.gov (United States)

    Song, Yulong; Ye, Zuliang; Cao, Feng

    2017-08-01

    In this study, an innovation of air-sourced transcritical CO2 heat pump which was employed in the space heating application was presented and discussed in order to solve the problem that the heating performances of the transcritical CO2 heat pump water heater deteriorated sharply with the augment in water feed temperature. An R134a cycle was adopted as a subcooling device in the proposed system. The prototype of the presented system was installed and supplied hot water for three places in northern China in winter. The field test results showed that the acceptable return water temperature can be increased up to 55°C, while the supply water temperature was raised rapidly by the presented prototype to up to 70°C directly, which was obviously appropriate to the various conditions of heating radiator in space heating application. Additionally, though the heating capacity and power dissipation decreased with the decline in ambient temperature or the augment in water temperature, the presented heat pump system performed efficiently whatever the climate and water feed temperature were. The real time COP of the presented system was generally more than 1.8 in the whole heating season, while the seasonal performance coefficient (SPC) was also appreciable, which signified that the economic efficiency of the presented system was more excellent than other space heating approaches such as fuel, gas, coal or electric boiler. As a result, the novel system will be a promising project to solve the energy issues in future space heating application.

  11. Development and application of soil coupled heat pump

    Science.gov (United States)

    Liu, Lu

    2017-05-01

    Soil coupled heat pump technology is a new clean heating mode, is the world's most energy efficient heating one of the ways. And because of the use of renewable geothermal resources with high heating performance so more and more people's attention. Although the use of soil-coupled heat pumps has been in use for more than 50 years (the first application in the United States), the market penetration of this technology is still in its infancy. This paper will focus on the development, characteristics and application of the coupled heat pump.

  12. Heat-pump-assisted dryer: Pt. 1; Mathematical model

    Energy Technology Data Exchange (ETDEWEB)

    Pendyala, V.R.; Devotta, S.; Patwardhan, V.S. (National Chemical Lab., Poona (India))

    1990-07-01

    A mathematical model for an integrated heat-pump-assisted dryer has been developed. The dryer has been modelled considering the heat transfer and simultaneous heat and mass transfer zones. The heat-pump heat exchangers have been modelled by writing the enthalpy balance for differential lengths considering the various zones on the air and working-fluid sides. The compressor has been described by the polytropic compression equation. The model has been used for simulating an existing system using R11 to study the effect of approach velocity of air to the evaporator and of the suction superheat on the specific energy consumption of the heat pump assisted dryer. (author).

  13. PV water pumping: NEOS Corporation recent PV water pumping activities

    Energy Technology Data Exchange (ETDEWEB)

    Lane, C.

    1995-11-01

    NEOS Corporation has been very active in PV-powered water pumping, particularly with respect to electric utilities. Most of the recent activity has been through the Photovoltaic Services Network (PSN). The PSN is an independent, not-for-profit organization comprised of all types of electric utilities: rural electric coops, public power districts, investor-owned utilities, and power marketing agencies. The PSN`s mission is to work pro-actively to promote utility involvement in PV through education and training. PV information is distributed by the PSN in three primary forms: (1) consultation with PSN technical service representatives: (2) literature generated by the PSN; and (3) literature published by other organizations. The PSN can also provide assistance to members in developing PV customer service programs. The PSN`s product support activities include consolidation of information on existing packaged PV systems and facilitation of the development of new PV product packages that meet utility-defined specifications for cost performance, and reliability. The PSN`s initial product support efforts will be focused on commercially available packaged PV systems for a variety of off-grid applications. In parallel with this effort, if no products exist that meet the PSN`s functional specifications, the PSN will initiate the second phase of product development support process by encouraging the development of new packaged systems. Through these services and product support activities, the PSN anticipates engaging all segments for the PV industry, thus providing benefits to PV systems suppliers as well as local PV service contractors.This paper describes field testing of pv power systems for water pumping.

  14. To the design of water-admitted heat exchangers for compression-type heat pumps with non-azetropic binary refrigerants. Zur Gestaltung von wasserbeaufschlagten Waermeuebertragern fuer Kompressionswaermepumpen mit nichtazeotropen Zweistoffkaeltemitteln

    Energy Technology Data Exchange (ETDEWEB)

    Heinrich, G. (Technische Univ., Dresden (Germany, F.R.). Sektion Energieumwandlung); Hempel, O. (ILKA Luft- und Kaeltetechnik Dresden GmbH (Germany, F.R.))

    1990-11-01

    The approximation to the 'Lorenz'-process by using of non-azeotropic refrigerant mixtures in heat pumps demands the proper design of evaporator and condenser with priority. Besides the adaption of interior temperature behaviours on exterior mass flows, the limiting of refrigerant pressure losses (specially in the evaporator) is important. Cross-counter flow heat exchangers are better suitable than a counter-flow heat exchanger to guarantee these two conditions. (orig.).

  15. Development of a hybrid chemical/mechanical heat pump

    Science.gov (United States)

    Grzyll, Lawrence R.; Silvestri, John J.; Scaringe, Robert P.

    1991-01-01

    The authors present the current development status of a hybrid chemical/mechanical heat pump for low-lift applications. The heat pump provides electronics cooling by evaporating a pure refrigerant from an absorbent/refrigerant mixture in a generator/cold plate. The current development focused on evaluation of absorbent/refrigerant pairs, corrosion testing, pump and compressor design, and electronic cold plate design. Two cycle configurations were considered. The first configuration utilized a standard mechanical compressor and pump. The second cycle configuration investigated pumps and compressors with non-moving parts. An innovative generator/cold plate design is also presented. The development to date shows that this cycle has about the same performance as standard vapor compression heat pumps with standard refrigerants but may have some performance and reliability advantages over vapor compression heat pumps.

  16. Development of a hybrid chemical/mechanical heat pump

    Science.gov (United States)

    Grzyll, Lawrence R.; Silvestri, John J.; Scaringe, Robert P.

    1991-01-01

    The authors present the current development status of a hybrid chemical/mechanical heat pump for low-lift applications. The heat pump provides electronics cooling by evaporating a pure refrigerant from an absorbent/refrigerant mixture in a generator/cold plate. The current development focused on evaluation of absorbent/refrigerant pairs, corrosion testing, pump and compressor design, and electronic cold plate design. Two cycle configurations were considered. The first configuration utilized a standard mechanical compressor and pump. The second cycle configuration investigated pumps and compressors with non-moving parts. An innovative generator/cold plate design is also presented. The development to date shows that this cycle has about the same performance as standard vapor compression heat pumps with standard refrigerants but may have some performance and reliability advantages over vapor compression heat pumps.

  17. Evaluating the Heat Pump Alternative for Heating Enclosed Wastewater Treatment Facilities in Cold Regions.

    Science.gov (United States)

    1982-05-01

    AD-A1uG 385 COLD RE61ONS RESEARCH AND ENGINEERING LAS HANOVER NH F/e 13/1 EVALUATING THE HEAT PUMP ALTERNATIVE FOR HEATING ENCLOSED WASTE--ETC(U) NAT...1982Enginee Cold Regions Research & Engineering Laboratory Evaluating the heat pump alternative for heating enclosed wastewater treatment facilities in...COVERED EVALUATING; THlE HEAT PUMP ALTERNATIVE FOR HEATING ENCLOSED WASTEWATER TREATMENT FACI~IITIES IN COLD REGIONS 6 PERFORMING ORG. REPORT NUMBER 7

  18. Thermodynamic Analysis of a Waste Heat Driven Vuilleumier Cycle Heat Pump

    OpenAIRE

    Yingbai Xie; Xuejie Sun

    2015-01-01

    A Vuilleumier (VM) cycle heat pump is a closed gas cycle driven by heat energy. It has the highest performance among all known heat driven technologies. In this paper, two thermodynamic analyses, including energy and exergy analysis, are carried out to evaluate the application of a VM cycle heat pump for waste heat utilization. For a prototype VM cycle heat pump, equations for theoretical and actual cycles are established. Under the given conditions, the exergy efficiency for the theoretical ...

  19. Air-to-water heat pumps, business for refrigeration systems experts. Marketing of energy-efficient technology; Luft/Wasser-Waermepumpen. Ein Geschaeft fuer Kaelteanlagenbauer. Vermarktung von energieeffizienter Technik

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    2009-01-15

    Many providers of refrigerating systems are already active in the private customer market offering split systems. There are less of them in the field of air-to-water heat pumps although this is also a growing market, and some producers of the air conditioning sector are already offering complete solutions. The contribution presents some sales arguments, outlines marketing tools for fitters - illustrated by the example of one provider -, and closes with a short market review. (orig.)

  20. Residential heat pumps in the future Danish energy system

    DEFF Research Database (Denmark)

    Petrovic, Stefan; Karlsson, Kenneth Bernard

    2016-01-01

    Denmark is striving towards 100% renewable energy system in 2050. Residential heat pumps are expected to be a part of that system.We propose two novel approaches to improve the representation of residential heat pumps: Coefficients of performance (COPs) are modelled as dependent on air and ground...... temperature while installation of ground-source heat pumps is constrained by available ground area. In this study, TIMES-DK model is utilised to test the effects of improved modelling of residential heat pumps on the Danish energy system until 2050.The analysis of the Danish energy system was done...... for politically agreed targets which include: at least 50% of electricity consumption from wind power starting from 2020, fossil fuel free heat and power sector from 2035 and 100% renewable energy system starting from 2050. Residential heat pumps supply around 25% of total residential heating demand after 2035...

  1. Geothermal heat pump system assisted by geothermal hot spring

    Science.gov (United States)

    Nakagawa, M.; Koizumi, Y.

    2016-01-01

    The authors propose a hybrid geothermal heat pump system that could cool buildings in summer and melt snow on the pedestrian sidewalks in winter, utilizing cold mine water and hot spring water. In the proposed system, mine water would be used as cold thermal energy storage, and the heat from the hot spring after its commercial use would be used to melt snow for a certain section of sidewalks. Neither of these sources is viable for direct use application of geothermal resources, however, they become contributing energy factors without producing any greenhouse gases. To assess the feasibility of the proposed system, a series of temperature measurements in the Edgar Mine (Colorado School of Mines' experimental mine) in Idaho Springs, Colorado, were first conducted, and heat/mass transfer analyses of geothermal hot spring water was carried out. The result of the temperature measurements proved that the temperature of Edgar Mine would be low enough to store cold groundwater for use in summer. The heat loss of the hot spring water during its transportation was also calculated, and the heat requirement for snow melt was compared with the heat available from the hot spring water. It was concluded that the heat supply in the proposed usage of hot spring water was insufficient to melt the snow for the entire area that was initially proposed. This feasibility study should serve as an example of "local consumption of locally available energy". If communities start harnessing economically viable local energy in a responsible manner, there will be a foundation upon which to build a sustainable community.

  2. Wind power integration in Aalborg Municipality using compression heat pumps and geothermal absorption heat pumps

    DEFF Research Database (Denmark)

    Østergaard, Poul Alberg

    2013-01-01

    -temperature geothermal resources. The analyses have also demonstrated that the municipality will still rely heavily on surrounding areas for electric load balancing assistance. With a departure in a previously elaborated 100% renewable energy scenario, this article investigates how absorption heat pumps (AHP......) and compression heat pumps (HP) for the supply of DH impact the integration of wind power. Hourly scenario-analyses made using the EnergyPLAN model reveal a boiler production and electricity excess which is higher with AHPs than with HPs whereas condensing mode power generation is increased by the application......Aalborg Municipality, Denmark is investigating ways of switching to 100% renewable energy supply over the next 40 years. Analyses so far have demonstrated a potential for such a transition through energy savings, district heating (DH) and the use of locally available biomass, wind power and low...

  3. Energy Optimization for Transcritical CO2 Heat Pump for Combined Heating and Cooling and Thermal Storage Applications

    DEFF Research Database (Denmark)

    Do Carmo, Carolina Madeira Ramos; Blarke, Morten; Yazawa, Kazuaki

    2012-01-01

    A transcritical heat pump (THP) cycle using carbon dioxide (CO2) as the refrigerant is known to feature an excellent coefficient of performance (COP) as a thermodynamic system. Using this feature, we are designing and building a system that combines a water-to-water CO2 heat pump with both hot...... and cold thermal storages know as Thermal Battery (TB) (Blarke, 2012). Smart and effective use of intermittent renewable energy resources (for example solar and wind power) is obtained supplying water heating (>70 oC) and cooling services (

  4. 3D-CFD Design Study And Optimization Of A Centrifugal Turbo Compressor For The Operation In A Hybrid Sorption/ Compression Heat Pump Cycle

    OpenAIRE

    Eckert, Thomas; Dostal, Leo; Helm, Martin; Schweigler, Christian

    2016-01-01

    In various applications the use of sorption chillers and heat pumps is limited by the available temperature level of the driving heat source or the heat sink for export of reject heat. These constraints can be overcome by integrating an efficient high-speed transonic turbo-compressor into the internal cycle of a thermally driven water/lithium bromide absorption heat pump. The operation in a hybrid heat pump with the refrigerant water implies specific challenges for the design of the compresso...

  5. Domestic heat pumps in the UK. User behaviour, satisfaction and performance

    Energy Technology Data Exchange (ETDEWEB)

    Caird, S.; Roy, R.; Potter, S. [Design Innovation Group, Dept. Design, Development, Environment and Materials, Faculty of Mathematics, Computing and Technology, The Open University, Milton Keynes, MK7 6AA (United Kingdom)

    2012-08-15

    Consumer adoption of microgeneration technologies is part of the UK strategy to reduce carbon emissions from buildings. Domestic heat pumps are viewed as a potentially important carbon saving technology, given the ongoing decarbonisation of the electricity supply system. To address the lack of independent evaluation of heat pump performance, the Energy Saving Trust undertook the UK's first large-scale heat pump field trial, which monitored 83 systems in real installations. As part of the trial, the Open University studied the consumers' experience of using a domestic heat pump. An in-depth user survey investigated the characteristics, behaviour, and satisfactions of private householders and social housing residents using ground source and air source heat pumps for space and/or water heating, and examined the influence of user-related factors on measured heat pump system efficiency. The surveys found that most users were satisfied with the reliability, heating, hot water, warmth and comfort provided by their system. Analysis of user characteristics showed that higher system efficiencies were associated with greater user understanding of their heat pump system, and more continuous heat pump operation, although larger samples are needed for robust statistical confirmation. The analysis also found that the more efficient systems in the sample were more frequently located in the private dwellings than at the social housing sites and this difference was significant. This is explained by the interaction between differences in the systems, dwellings and users at the private and social housing sites. The implications for heat pump research, practice and policy are discussed.

  6. Measurement and Evaluation of Heating Performance of Heat Pump Systems Using Wasted Heat from Electric Devices for an Electric Bus

    OpenAIRE

    Moo-Yeon Lee; Jong-Phil Won; Chung-Won Cho; Ho-Seong Lee

    2012-01-01

    The objective of this study is to investigate heating performance characteristics of a coolant source heat pump using the wasted heat from electric devices for an electric bus. The heat pump, using R-134a, is designed for heating a passengers’ compartment by using discharged energy from the coolant of electric devices, such as motors and inverters of the electric bus. The heating performance of the heat pump was tested by varying the operating parameters, such as outdoor temperature and volum...

  7. The Pumping Up Phenomenon of Double-Stage Bubble Pump with Water and Aqueous LiBr Solution

    Directory of Open Access Journals (Sweden)

    Hongtao Gao

    2013-02-01

    Full Text Available The double-stage bubble pump, using thermal energy as driving force to transport the solution, can replace the mechanical solution pump in the double-effect lithium bromide absorption chiller. By building a bench, a lot of experimental research and analysis were conducted with water and different concentrations of lithium bromide solution as the working fluid of the bubble pump. The first-stage bubble pump in the experiment pumps up by the external heat source. The heat for driving the second-stage bubble pump is provided by refrigerant steam produced from the first-stage bubble pump. The experiment data shows that the heating of refrigerant vapor is only one of the elements of pump-up phenomenon. Another is that the intermediate solution flashes to vapor to become bubbles. The pump-up phenomenon of double-stage bubble pump has much to do with the pressure difference of intermediate solution and first-stage refrigerant vapor. With water as the working fluid, when the pressure difference between refrigerant vapor and the intermediate liquefied refrigerant is 3.5-3.9 kPa, the bubble pump can pump up and run for some time and the start-up time decreases with the driving head. When the working fluid is lithium bromide solution, the pressure difference of the double-stage bubble pump increases with the solution concentration and is bigger than that of water. The start-up time increases with the concentrations of lithium bromide solution within the range of 45.5 to 54% and decreases within the range of 54-59.5%. The start-up time is largest at 54% under this experimental condition. The experimental result is also compared with the single-stage bubble pump. The start-up time of double-stage bubble pump decreases with the driving height, which is contrary to the single-stage bubble pump.

  8. 工程型太阳能热泵热水系统节能效益分析%Energy-saving Benefit Analysis of Engineering Type Solar Energy Hot Water System in Conjunction with Heat Pump

    Institute of Scientific and Technical Information of China (English)

    2013-01-01

    According to the engineering case region meteorological data and solar resource characteristics,the solar energy centralized heating system in Conjunction with heat pump used in the hotel is analyzed based on saving benefits. By means of comprehensive analyzing of annual amount of energy saving,cost saving,payback period for the increase of the initial investment,as well as environmental benefits of the solar energy heat pump hot water system,it is indicated that solar energy heat pump hot water system project not only has the very high heat efficiency and environmental adaptability but also has high economy efficiency. It is a kind of heating water systems of ideal high quality.%  根据工程案例地区气象参数及太阳能资源特点,对已投入宾馆使用的太阳能热泵集中供热水系统进行节能效益分析。通过对太阳能热泵热水系统的年节能量,节省费用,系统增加的初投资的回收年限,以及太阳能热泵热水系统的环保效益进行综合分析。表明工程型太阳能热泵热水系统不仅具有很高的热效率和环境适应性同时具有较高的经济性,是一种理想的高品质供热水系统。

  9. Operation Characteristics of Ground Source Heat Pump for Centralized Hot Water Supply in High-rise Buildings%地源热泵用于高层建筑集中供热水的运行特性

    Institute of Scientific and Technical Information of China (English)

    王艳; 胡映宁; 林俊

    2012-01-01

    自主设计了地源热泵热水/空调冷热联供系统和单纯的地源热泵供热水系统,并将其应用于高层建筑中.运用单因素方法,研究循环介质流量等对热泵系统运行特性的影响,确定最佳流量,并通过测试计算系统的能耗.结果表明,在地源热泵热水/空调冷热联供系统中,采用地源制热水时的机组能效比和系统能效比分别为4.7和4.2,冷热联供时的机组综合能效比和系统综合能效比分别为8.63和6.39;系统全年制热水耗电量为6.35 kW·h/m3,与电锅炉加热方式和太阳能+电辅助加热方式相比,可分别节省82.2%和46.7%的电量.在单纯的地源热泵供热水系统中,机组能效比和系统能效比分别为4.8和4.3,全年制热水总耗电量为11.13 kW·h/m3,与电锅炉加热方式和太阳能+电辅助加热方式相比,可分别节省74.69%和24%的电量.由此说明,地源热泵集中供热水系统应用于高层建筑的节能效果显著.%A ground source heat pump hot-water/air-conditioning system and a stand-alone ground source heat pump hot-water system were designed and used in high-rise buildings. The influence of circulation medium flow on the operation characteristics of heat pump system was studied, the optimal flow was determined, and the energy consumption of the systems was calculated by testing. The results showed that for the ground source heap pump hot-water/air-conditioning system, the unit energy efficiency ratio and the system energy efficiency ratio were 4. 7 and 4. 2, respectively, when supplying hot water. The unit integrated energy efficiency ratio and the system integrated energy efficiency ratio were 8. 63 and 6. 39, respectively, when supplying hot water and cooling. The annual power consumption for supplying hot water was 6. 35 kW · h/m3, and the power savings were 82. 2% and 46. 7% compared with electric boiler heating and solar electric heating. For the ground source heat pump hot-water system, the

  10. Norwegian participation in the IEA Heat Pump Programme Annex 34 - final report

    Energy Technology Data Exchange (ETDEWEB)

    Nordtvedt, S.R.

    2012-07-01

    This report is the Norwegian team contribution to Task A within the IEA Heat Pumps Programme Annex 34 on #Left Double Quotation Mark#Thermally driven heat pumps#Right Double Quotation Mark#. It aims to give an overview of the thermally driven heat pump (TDHP) and chiller (TDC) market, recent developments in the area of TDHP and TDC, as well as to give an outlook of the progress of this technology. There are no Norwegian manufacturers on the TDHP market. There are only seven existing thermally driven absorption system installations in Norway. Three are district heat driven water/LiBr chillers, one is a steam driven water/LiBr chiller, one water/LiBr heat pump for flue gas condensation in a wood chip heating unit, and two gas driven ammonia-water chillers. The future market for thermally driven heat pumps and chillers in Norway is expected to be in combination of biomass, district heat or waste heat. (Author)

  11. Optimal Ground Source Heat Pump System Design

    Energy Technology Data Exchange (ETDEWEB)

    Ozbek, Metin [ENVIRON; Yavuzturk, Cy [University of Hartford; Pinder, George [University of Vermont

    2015-04-15

    Despite the facts that GSHPs first gained popularity as early as the 1940’s and they can achieve 30 to 60 percent in energy savings and carbon emission reductions relative to conventional HVAC systems, the use of geothermal energy in the U.S. has been less than 1 percent of the total energy consumption. The key barriers preventing this technically-mature technology from reaching its full commercial potential have been its high installation cost and limited consumer knowledge and trust in GSHP systems to deliver the technology in a cost-effective manner in the market place. Led by ENVIRON, with support from University Hartford and University of Vermont, the team developed and tested a software-based a decision making tool (‘OptGSHP’) for the least-cost design of ground-source heat pump (‘GSHP’) systems. OptGSHP combines state of the art optimization algorithms with GSHP-specific HVAC and groundwater flow and heat transport simulation. The particular strength of OptGSHP is in integrating heat transport due to groundwater flow into the design, which most of the GSHP designs do not get credit for and therefore are overdesigned.

  12. Optimal Ground Source Heat Pump System Design

    Energy Technology Data Exchange (ETDEWEB)

    Ozbek, Metin [Environ Holdings Inc., Princeton, NJ (United States); Yavuzturk, Cy [Univ. of Hartford, West Hartford, CT (United States); Pinder, George [Univ. of Vermont, Burlington, VT (United States)

    2015-04-01

    Despite the facts that GSHPs first gained popularity as early as the 1940’s and they can achieve 30 to 60 percent in energy savings and carbon emission reductions relative to conventional HVAC systems, the use of geothermal energy in the U.S. has been less than 1 percent of the total energy consumption. The key barriers preventing this technically-mature technology from reaching its full commercial potential have been its high installation cost and limited consumer knowledge and trust in GSHP systems to deliver the technology in a cost-effective manner in the market place. Led by ENVIRON, with support from University Hartford and University of Vermont, the team developed and tested a software-based a decision making tool (‘OptGSHP’) for the least-cost design of ground-source heat pump (‘GSHP’) systems. OptGSHP combines state of the art optimization algorithms with GSHP-specific HVAC and groundwater flow and heat transport simulation. The particular strength of OptGSHP is in integrating heat transport due to groundwater flow into the design, which most of the GSHP designs do not get credit for and therefore are overdesigned.

  13. Multi-Temperature Heat Pump with Cascade Compressor Connection

    Directory of Open Access Journals (Sweden)

    Sit M.L.

    2017-08-01

    Full Text Available The object of the study is a multifunctional heat pump with several evaporators and condensers designed for simultaneous provision of technological processes with heat and cold. The aim of the work is the development and study of the scheme for this type of heat pumps, which ensures minimum irreversibility in the "compressor-gas coolers" chain, without the use of adjustable ejectors installed after evaporators and used as flow mixers. The obtained technical solution ensures the stabilization of the heat pump coefficient of performance (COP and prescribed thermal regimes of heat exchangers at a variable flow rate of the refrigerant. The novelty of the elaboration is inclusion a compressor of the first stage with a serially connected intermediate heat exchanger and a control valve that are located before the compressor inlet of the second stage of the heat pump, which allows to establish a rational pressure after the first stage of the compressors. A scheme is proposed for regulating the temperature at the inlet of the first stage compressors by regulating the flow through the primary circuits of the recuperative heat exchangers. The first stage compressor control system allows providing the required modes of operation of the heat pump. It is established, because of the exergetic analysis of the sections of the hydraulic circuit of heat pump located between the evaporators and gas coolers that the reduction of irreversible losses in the heat pump is ensured due to the optimal choice of the superheat value of the gas after the evaporators.

  14. Performance and Characteristics of Heat Pump Clothes Drier

    Science.gov (United States)

    Ambarita, H.; Nasution, D. M.; Gunawan, S.; Nasution, A. H.

    2017-03-01

    In this paper, a study of clothes drying using a heat pump drier has been carried out. The objective is to examine the performance and drying characteristics of the heat pump clothes dryer. The result of performances and drying characteristics were compared with waste heat drying system of split-type residential air conditioner (RAC). A drying chamber with volume 1 m3 integrated with heat pump component had been designed and fabricated. The heat pump operated by vapor compression cycle with power input of 800W and refrigerant R22 as a working fluid. The clothes dried made of pure cotton with initial weight varied from 3.00 kg, 5.25 kg, and 6.38 kg, respectively. The results shown that the drying time and drying rate of heat pump drier are faster than waste heat drying system. The average total performance of heat pump clothes drier is 6.56. On the other hand, SMER which is obtained 1.492 kg/kWh. These values are lower than the SMER of waste heat drying system which shown the average value of 2.492 kg/kWh. In the case of drying clothes, waste heat drying of RAC shows a better performance in comparison with heat pump drying system.

  15. Water cooling thermal power measurement in a vacuum diffusion pump

    Directory of Open Access Journals (Sweden)

    Luís Henrique Cardozo Amorin

    2012-04-01

    Full Text Available Diffusion vacuum pumps are used both in industry and in laboratory science for high vacuum production. For its operation they must be refrigerated, and it is done by circulating water in open circuit. Considering that, vacuum systems stays operating by hours, the water consumption may be avoided if the diffusion vacuum pumps refrigeration were done in closed circuit. However, it is necessary to know the diffusion vacuum pump thermal power (the heat transferred to circulate water by time units to implement one of these and get in the refrigeration system dimension. In this paper the diffusion vacuum pump thermal power was obtained by measuring water flow and temperature variation and was calculated through the heat quantity variation equation time function. The thermal power value was 935,6 W, that is 397 W smaller and 35 W bigger than, respectively, the maximum and minimum diffusion pump thermal power suggested by its operation manual. This procedure have been shown useful to precisely determine the diffusion pump thermal power or of any other system that needs to be refrigerated in water closed circuit.

  16. Vapor Compression and Thermoelectric Heat Pumps for a Cascade Distillation Subsystem: Design and Experiment

    Science.gov (United States)

    Erickson, Lisa R.; Ungar, Eugene K.

    2012-01-01

    Humans on a spacecraft require significant amounts of water for drinking, food, hydration, and hygiene. Maximizing the reuse of wastewater while minimizing the use of consumables is critical for long duration space exploration. One of the more promising consumable-free methods of reclaiming wastewater is the distillation/condensation process used in the Cascade Distillation Subsystem (CDS). The CDS heats wastewater to the point of vaporization then condenses and cools the resulting water vapor. The CDS wastewater flow requires heating for evaporation and the product water flow requires cooling for condensation. Performing the heating and cooling processes separately would require two separate units, each of which would demand large amounts of electrical power. Mass, volume, and power efficiencies can be obtained by heating the wastewater and cooling the condensate in a single heat pump unit. The present work describes and compares two competing heat pump methodologies that meet the needs of the CDS: 1) a series of mini compressor vapor compression cycles and 2) a thermoelectric heat exchanger. In the paper, the CDS system level requirements are outlined, the designs of the two heat pumps are described in detail, and the results of heat pump analysis and performance tests are provided. The mass, volume, and power requirement for each heat pump option is compared and the advantages and disadvantages of each system are listed.

  17. Heat pump assisted drying of agricultural produce-an overview.

    Science.gov (United States)

    Patel, Krishna Kumar; Kar, Abhijit

    2012-04-01

    This review paper included the recent progress made in heat pump assisted drying, its principle, mechanism and efficiency, type and its application for drying of agricultural produce. Heat pump assisted drying provides a controllable drying environment (temperature and humidity) for better products quality at low energy consumption. It has remarkable future prospects and revolutionaries ability. The heat pump system consists of an expansion valve, two heat exchangers (evaporator and condenser), and a compressor, which are connected by using copper tubes. In this paper we also provided a review discussion on different type of heat pump assisted drying system ready for remarkable and commercial use in different type of food industries. Here we also have given some major advantage and disadvantage of heat pump assisted drying.

  18. Ground coupled solar heat pumps: analysis of four options

    Energy Technology Data Exchange (ETDEWEB)

    Andrews, J.W.

    1981-01-01

    Heat pump systems which utilize both solar energy and energy withdrawn from the ground are analyzed using a simplified procedure which optimizes the solar storage temperature on a monthly basis. Four ways of introducing collected solar energy to the system are optimized and compared. These include use of actively collected thermal input to the heat pump; use of collected solar energy to heat the load directly (two different ways); and use of a passive option to reduce the effective heating load.

  19. Coabsorbent and thermal recovery compression heat pumping technologies

    CERN Document Server

    Staicovici, Mihail-Dan

    2014-01-01

    This book introduces two of the most exciting heat pumping technologies, the coabsorbent and the thermal recovery (mechanical vapor) compression, characterized by a high potential in primary energy savings and environmental protection. New cycles with potential applications of nontruncated, truncated, hybrid truncated, and multi-effect coabsorbent types are introduced in this work.   Thermal-to-work recovery compression (TWRC) is the first of two particular methods explored here, including how superheat is converted into work, which diminishes the compressor work input. In the second method, thermal-to-thermal recovery compression (TTRC), the superheat is converted into useful cooling and/or heating, and added to the cycle output effect via the coabsorbent technology. These and other methods of discharge gas superheat recovery are analyzed for single-, two-, three-, and multi-stage compression cooling and heating, ammonia and ammonia-water cycles, and the effectiveness results are given.  The author presen...

  20. Influence of heat storage mode of domestic hot water on the performance of ground heat exchanger in ground-source heat pump system%卫生热水蓄热方式对地埋管换热性能的影响分析

    Institute of Scientific and Technical Information of China (English)

    王勇; 唐曦

    2012-01-01

    竖埋管地源热泵系统为室内环境控制提供冷热量。在空调工况下,热回收机组可以提供卫生热水。卫生热水的供应在冬夏不同的运行模式下,对地埋管的换热性能影响不同。通过某地源热泵工程设计,分析了冬夏季卫生热水系统在蓄热方式下对地源热泵系统地埋管换热性能的影响。利用卫生热水的蓄热能力,对地埋管换热器在不同工况下的动态换热性能进行了对比分析,并通过数值计算得到了不同运行模式下地埋管的换热性能参数。根据计算结果提出了在该工程负荷特性下的系统调节方式。%The vertical U-tube ground-coupled heat pump system provides cold and heat for the controlling of indoor environment.Under the air-conditioning condition,the vertical U-tube ground-coupled heat pump system with heat recovery can provide domestic hot water.The influence of supplying domestic hot water on the heat transfer performance of ground heat exchangers is different under different operating modes in summer and winter.Through a project design of ground-source heat pump system,the influence of supplying domestic hot water under heat storage mode on the heat transfer performance of ground heat exchangers in summer and winter is respectively analyzed.The dynamic performance of heat exchangers under different working conditions is analyzed,and through numerical calculation,the heat transfer performance parameters of ground heat exchangers under different operating modes are obtained.From the calculation results,the adjusting methods based on the load characteristics of this project represent.

  1. Application and summary of fresh water-source heat pump system in Chengdu Jinjiangchuangyi Science and Technology Building%成都锦江创意科技大厦淡水源热泵应用及总结

    Institute of Scientific and Technical Information of China (English)

    王波; 徐净宇; 黄进

    2012-01-01

    The project is a demonstration project of renewable energy application in buildings, adopting a fresh water-source heat pump system for cooling, heating and domestic hot water supply. To realize the system energy efficiency ratio over 3.0 both in winter and summer, considering the water quality of the water source, adopts the scheme of the water entering the heat pump unit directly. By selecting anti-corrosion units and installing rubber-ball cleaning devices, guarantees the stability of system operation.%该工程为可再生能源建筑应用示范工程,采用淡水源热泵系统为建筑供冷、供热和生活热水提供冷热源.为达到示范工程所要求的冬夏季系统能效比均在3.0以上,结合该工程的水源水质情况,采用了水源水直接进热泵主机的方案;通过选用耐腐蚀的水源热泵主机并加装胶球清洗装置,保证了系统的稳定运行.

  2. 2012 International Conference on Medical Physics and Biomedical Engineering Thermal Economic Analysis on LiBr Refrigeration -Heat Pump System Applied in CCHP System

    Science.gov (United States)

    Zhang, CuiZhen; Yang, Mo; Lu, Mei; Zhu, Jiaxian; Xu, Wendong

    LiBr refrigeration cooling water contains a lot of low-temperature heat source, can use this part of the heat source heat boiler feed water. This paper introduced LiBr refrigeration - heat pump system which recovery heat of the LiBr refrigeration cooling water by heat pump system to heat the feed water of boiler. Hot economic analysis on the system has been performed based on the experimental data. Results show that LiBr refrigeration-heat pump system brings 26.6 percent decrease in primary energy rate consumption comparing with the combined heat and power production system(CHP) and separate generation of cold;

  3. Performance of Gas-Engine Driven Heat Pump Unit

    Energy Technology Data Exchange (ETDEWEB)

    Abdi Zaltash; Randy Linkous; Randall Wetherington; Patrick Geoghegan; Ed Vineyard; Isaac Mahderekal; Robert Gaylord

    2008-09-30

    Air-conditioning (cooling) for buildings is the single largest use of electricity in the United States (U.S.). This drives summer peak electric demand in much of the U.S. Improved air-conditioning technology thus has the greatest potential impact on the electric grid compared to other technologies that use electricity. Thermally-activated technologies (TAT), such as natural gas engine-driven heat pumps (GHP), can provide overall peak load reduction and electric grid relief for summer peak demand. GHP offers an attractive opportunity for commercial building owners to reduce electric demand charges and operating expenses. Engine-driven systems have several potential advantages over conventional single-speed or single-capacity electric motor-driven units. Among them are variable speed operation, high part load efficiency, high temperature waste heat recovery from the engine, and reduced annual operating costs (SCGC 1998). Although gas engine-driven systems have been in use since the 1960s, current research is resulting in better performance, lower maintenance requirements, and longer operating lifetimes. Gas engine-driven systems are typically more expensive to purchase than comparable electric motor-driven systems, but they typically cost less to operate, especially for commercial building applications. Operating cost savings for commercial applications are primarily driven by electric demand charges. GHP operating costs are dominated by fuel costs, but also include maintenance costs. The reliability of gas cooling equipment has improved in the last few years and maintenance requirements have decreased (SCGC 1998, Yahagi et al. 2006). Another advantage of the GHP over electric motor-driven is the ability to use the heat rejected from the engine during heating operation. The recovered heat can be used to supplement the vapor compression cycle during heating or to supply other process loads, such as water heating. The use of the engine waste heat results in greater

  4. Application Examples of Heat Pump Central Air Conditioning of Water Source of Poyang Lake%鄱阳湖水源热泵中央空调运用实例

    Institute of Scientific and Technical Information of China (English)

    曾宇军

    2014-01-01

    Through the selection of model test of central air conditioning cooling and heating mode of Poyang Lake, the author introduces the composition and operation of lake water source heat pump and ground source ground principle coupled heat exchanger auxiliary heating system, analyzing the system operation ef iciency, which has obtained the good use ef ect, and providing a theoretical basis and examples of templates for water source heat pump project in Poyang Lake region.%通过鄱阳湖模型试验研究基地中央空调供冷供热方式的比选,介绍了湖水源热泵和地源土壤耦合换热器辅助供热系统组成和运行原理,进行了该系统运行的效益分析,取得了较好的使用效果,为环鄱阳湖区域利用水源热泵工程提供了理论依据和实例样板。

  5. 欧盟空气源热泵(静态)热水器生态设计测试研究%Study of the Test about Ecodesign of Air Source Heat Pump (Static) Water Heater in European Market

    Institute of Scientific and Technical Information of China (English)

    马洁丹; 臧松彦

    2015-01-01

    本文结合法规EU No.812/2013、 EU No.814/2013和标准EN 16147:2011对空气源热泵热水器的ERP测试方法和要求进行分析和总结,并提出测试过程中的各个注意事项,以便读者更好了解新法规对热泵能效的测试要求。%This paper analyzed and summarized the ERP test of Air source heat pump water heater, with the code of EU No.812/2013, EU No.814/2013 and the standard of EN 16147: 2011, and brought forward notice of the test, for the reader knowing more about the energy efficiency test of heat pump.

  6. IEA Annex 21. Global environmental benefits of industrial heat pumps; IEA Annex 21. Globala miljoefoerdelar med industriella vaermepumpar

    Energy Technology Data Exchange (ETDEWEB)

    Westermark, M. [Royal Inst. of Tech., Stockholm (Sweden). Dept. of Chemical Engineering and Technology

    1996-12-01

    Industrial heat pumps uses heat from an industrial process as heat source (e.g. cooling water, waste steam, or flue gas). The study thus excludes heat pumps using natural heat sources as sea water or ambient air. The advantage of industrial heat pumps are high heat source temperature (often 30-100 deg C) and high operational time (industries are often operated during the whole year). Produced heat from the heat pump replaces oil or other fuels for process heating or is exported to a district heating network. The total number of industrial heat pumps in the 8 participating countries was approx. 4600. About 2700 are used for drying of wood products and are small by Swedish standards (50-150 kW/unit). Other sectors with large numbers of heat pumps are food industry (1100 units) and chemical industry (350 units). The remaining 460 units are used in textile industry, steel industry and pulp and paper industry. Sweden has relatively few industrial heat pumps (150 units). However, the produced heat is about 500 MW and in terms of installed capacity Sweden is among the leading countries for upgrading of industrial heat sources. The energy saving potential for industrial heat pumps was computed to 2-4 % of the industrial fuel consumption (if profitability has to be obtained). About the same reductions can be reached for carbon dioxide as well as sulphur dioxide, dust, nitric oxide and hydrocarbons. In Sweden heating alternatives with low carbon dioxide emission is already common (hydro power, nuclear power, biofuels, and heat pumps). The potential for further carbon dioxide savings by industrial heat pumps is therefore relatively less than in most other countries. 16 figs, 6 tabs

  7. Electrical heat pumps - a renewable energy? What is the environmental balance of electrical heat pumps in comparison to other heating systems?; Elektrische Waermepumpen - eine erneuerbare Energie? Wie ist die Umweltbilanz elektrischer Waermepumpen im Vergleich zu anderen Heizungssystemen?

    Energy Technology Data Exchange (ETDEWEB)

    Schuberth, Jens; Kaschenz, Helmut [Umweltbundesamt Dessau (Germany). Fachgebiet I 2.4 Energieeffizienz

    2008-05-29

    Electrical heat pumps deliver energy for the heating of buildings whereby relatively ambient heat from soil, water or air is increased on a usable temperature level. In this case, electrical power is used. Electrical heat pumps do not only use renewable environmental energy, but also electricity from not-renewable sources of energy. An installation and a correct adjustment of a heat meter are recommended. The calculation of production costs should consider not only the operating cost, but also all resulting costs in a total cost calculation. Electrical heat pumps offer a high discharge of the environment, if electric power effectively is produced. In this case, electrical heat pumps can exceed also fuel cells.

  8. Harnessing geothermal energy with heat pumps : a literature review

    Energy Technology Data Exchange (ETDEWEB)

    Arisi, J.A. [Memorial Univ. of Newfoundland, St. John' s, NL (Canada). Dept. of Civil Engineering

    2009-07-01

    Fossil fuel combustion emits large amounts of greenhouse gases (GHGs) into the atmosphere. Renewable fuel sources that do not have a negative impact on the environment are needed to reduce the risk of climatic change. This abstract discussed recent research related to geothermal energy. Two types of geothermal energy were investigated: (1) deep underground heat using turbines to produce electricity; and (2) shallow depth heat using heat pumps to provide space heating. A review of recent research on shallow depth heat harnessing was presented. The costs and GHG emission reductions related to the installation of a geothermal heat pump system for space heating were also discussed.

  9. R32用于泳池热泵热水器的性能实验探究%Research on the Performance of R32 in Heat Pump Water Heaters for Swimming Pool

    Institute of Scientific and Technical Information of China (English)

    2012-01-01

      本文对R22、R410A和R32用于泳池热泵热水器中的性能进行了理论分析和实验验证。结果表明,在相同的工况下,R32在热泵热水器中作为R22的替代物制热能力提高约9.4%,水循环一次循环出水温度提高0.3℃。 R32在热泵热水器领域的应用具有十分广阔的前景。%This paper provides theoretical calculations and experiments to test the performances of R32, R410A and R22 in heat pump water heaters. The results show that under the same working condition, the heat-ing capacity of R32 is about 9. 4% higher than that of R22;temperature rise of water circle in R32 prototype in-creases 0. 3℃ than that of R22. In a word, R32 is a promising alternative to R22 in heat pump water heater.

  10. Improved reliability of residential heat pumps; Foerbaettrad driftsaekerhet hos villavaermepumpar

    Energy Technology Data Exchange (ETDEWEB)

    Haglund Stignor, Caroline; Larsson, Kristin; Jensen, Sara; Larsson, Johan; Berg, Johan; Lidbom, Peter; Rolfsman, Lennart

    2012-07-01

    Today, heat pump heating systems are common in Swedish single-family houses. Many owners are pleased with their installation, but statistics show that a certain number of heat pumps break every year, resulting in high costs for both insurance companies and owners. On behalf of Laensfoersaekringars Forskningsfond, SP Energy Technology has studied the cause of the most common failures for residential heat pumps. The objective of the study was to suggest what measures to be taken to reduce the number of failures, i.e. improving the reliability of heat pumps. The methods used were analysis of public failure statistics and sales statistics and interviews with heat pump manufacturers, installers, service representatives and assessors at Laensfoersaekringar. In addition, heat pump manuals have been examined and literature searches for various methods for durability tests have been performed. Based on the outcome from the interviews the most common failures were categorized by if they; 1. Could have been prevented by better operation and maintenance of the heat pump. 2. Caused by a poorly performed installation. 3. Could have been prevented if certain parameters had been measured, recorded and followed up. 4. Are due to poor quality of components or systems. However, the results show that many of the common failures fall into several different categories and therefore, different types of measures must be taken to improve the operational reliability of residential heat pumps. The interviews tell that failures often are caused by poor installation, neglected maintenance and surveillance, and poor quality of standard components or that components are used outside their declared operating range. The quality of the installations could be improved by increasing installers' knowledge about heat pumps and by requiring that an installation protocol shall be filled-in. It is also important that the owner of the heat pump performs the preventive maintenance recommended by the

  11. Application of Air Source Heat Pump plus Solar Energy in Domestic Hot Water Preparation System%空气源热泵+太阳能在热水制备系统中的应用

    Institute of Scientific and Technical Information of China (English)

    李超; 卢强; 郭萌; 赵勇

    2015-01-01

    This paper analyzes the commonly used heating modes and gives a detailed introduction of both air source heat pump technology and solar heating technology. Combined with the actual project, the steam heating system of hot water is changed into air source heat pump plus solar heating. By analyzing the actual enetgy consumption data, we obtain the energy -saving value, thus achieve the goal of energy efficiency.%通过对常用供热方式的分析,并对空气源热泵技术、太阳能制热技术原理的介绍,结合工程实际情况,将原蒸汽加热制热水方式改造为空气源热泵+太阳能制热。通过对实际能耗数据的经济分析,得出改造后的节能价值,达到了节约能源的目的。

  12. Experimental study on energy performance of clean air heat pump

    DEFF Research Database (Denmark)

    Fang, Lei; Nie, Jinzhe; Olesen, Bjarne W.

    2014-01-01

    to investigate its energy performance. Energy consumption of the prototype of CAHP was measured in laboratory at different climate conditions including mild-cold, mildhot and extremely hot and humid climates. The energy saving potential of the clean air heat pump compared to a conventional ventilation and air......-conditioning system was calculated. The experimental results showed that the clean air heat pump saved substantial amount of energy compared to the conventional system. For example, the CAHP can save up to 59% of electricity in Copenhagen, up to 40% of electricity in Milan and up to 30% of electricity in Colombo......An innovative clean air heat pump (CAHP) was designed and developed based on the air purification capacity of regenerative silica gel rotor. The clean air heat pump integrated air purification, dehumidification and cooling in one unit. A prototype of the clean air heat pump was developed...

  13. Heat pumps - Even more efficient and quieter; Waermepumpen - noch effizienter und leiser

    Energy Technology Data Exchange (ETDEWEB)

    Kopp, T.

    2003-07-01

    These comprehensive proceedings contain nine presentations made at the 10th Conference held by the Swiss Research Programme on Environmental Heat, Combined Heat and Power Generation (CHP) and Refrigeration in Burgdorf, Switzerland in June 2003. In a paper by Stefen Bertsch, Peter Hubacher and Prof. Dr. Max Ehrbar, methods of freeing the evaporators used in air-water heat pumps of ice is examined, Prof. Dr. Thomas Afjei introduces standardised schematics for heat pump installations, Dr. Hans Rudolf Graf presents the results of research into noise reduction for air-water heat pumps and Dr. Esfandiar Shafai reports on pulse-width-modulation for small heat pumps. A further paper covers the use of ammonia in small heat pumps (Ewald Geisser). Dr. Martin Zogg looks back on 10 years of heat pump research at the Swiss Federal Office of Energy whilst Prof. Dr. Thomas Kopp takes a look at the future activities of the programme. Finally, Prof. Dr. Max Ehrbar discusses strategies for and the implementation of pilot and demonstration plants.

  14. Heat pumps - Even more efficient and quieter; Waermepumpen - noch effizienter und leiser

    Energy Technology Data Exchange (ETDEWEB)

    Kopp, T.

    2003-07-01

    These comprehensive proceedings contain nine presentations made at the 10th Conference held by the Swiss Research Programme on Environmental Heat, Combined Heat and Power Generation (CHP) and Refrigeration in Burgdorf, Switzerland in June 2003. In a paper by Stefen Bertsch, Peter Hubacher and Prof. Dr. Max Ehrbar, methods of freeing the evaporators used in air-water heat pumps of ice is examined, Prof. Dr. Thomas Afjei introduces standardised schematics for heat pump installations, Dr. Hans Rudolf Graf presents the results of research into noise reduction for air-water heat pumps and Dr. Esfandiar Shafai reports on pulse-width-modulation for small heat pumps. A further paper covers the use of ammonia in small heat pumps (Ewald Geisser). Dr. Martin Zogg looks back on 10 years of heat pump research at the Swiss Federal Office of Energy whilst Prof. Dr. Thomas Kopp takes a look at the future activities of the programme. Finally, Prof. Dr. Max Ehrbar discusses strategies for and the implementation of pilot and demonstration plants.

  15. History of heat pumps - Swiss contributions and international milestones

    Energy Technology Data Exchange (ETDEWEB)

    Zogg, M.

    2008-05-15

    Compared to conventional boilers, heating by heat pumps cuts down fuel consumption and CO{sub 2} emissions to about 50%. Compared to electric resistance heating, the energy consumption is even reduced up to 80%. Therefore, the impressive market penetration growth of heat pumps will continue. Swiss pioneers were the first to realize functioning vapour recompression plants. The first European heat pumps were realized in Switzerland. To date it remains one of the heat pump champions. Swiss pioneering work in the development of borehole heat exchangers, sewage heat recovery, oil free piston compressors and turbo compressors is well known. The biggest heat pump ever built comes from Switzerland. Although there is a fairly comprehensive natural gas distribution grid, 75% of the new single-family homes built in Switzerland are currently heated by heat pumps. This paper presents some of the highlights of this success story focusing on Swiss developments and relating them to the international milestones. In order to indicate the direction in which the future development might go to, some recent Swiss research projects are presented as well. (author)

  16. COMPARATIVE EFFICIENCY OF HEAT-PUMPS APPLICATION IN LOW TEMPERATURE HEAT SUPPLY SYSTEMS

    Directory of Open Access Journals (Sweden)

    M. N. Chepurnoy

    2015-01-01

    Full Text Available The  article  considers  comparative  operation-efficiency  of  the  low-temperature  heatsupply systems with heat pumping plants (HPP and with hot-water boilers. The paper shows that for energy evaluation of the alternative heat-supply systems effectiveness one cannot employ the transformation ratio (heating coefficient and the fuel heat-utilization factor in the HPP. Nonetheless the transformation ratio enters the formulae designating the efficiency of HPP operation. The authors obtain a generalized formula for ascertainment of transformation ratio and suggest evaluating the operation efficiency of the heat-supply systems by means of indicators specifying relative gain in the exergy-efficiency factor, fuel savings and saving expenditures connected with fuel and utilities. They attain formulae and build nomographic charts for those indicators ascertainment. The operation-efficiency comparative analysis of the low-temperature heat supply systems with HPP and with hot-water boilers shows that the HPP systems increase their effectiveness with transformation ratio, fuel price increase as well as with low electric-energy prices. The article specifies that with fuel low prices, the transformation-ratios limiting values with which the HPP operation-efficacy gains, grow. Energy-efficiency increase in the HPP does not always guaranty their economic effectiveness. These findings are true only for the heating systems. The hot water-supply systems will require the HPP condenser water additional heating to the assumed temperature from another thermal source, which reduces the effectiveness of the heat pump plants utilizing.

  17. EVALUATION OF DYNAMIC CARACTERISTICS OF GAS COOLER OF THE CARBON DIOXIDE HEAT PUMP ÎN THE TRANSCRITICAL CYCLE

    Directory of Open Access Journals (Sweden)

    Sit M.L.

    2008-12-01

    Full Text Available Dynamic characteristics of heat pump gas cooler obtained by means of the solution of the dynamics equations in partial derivatives are examined. Control system of the heat pump used for the heating of the heating–system water, supplied from CHP to the district heating system is examined. Possibility of PID-controller with gain scheduling utilization with the coefficients changing depending on gas cooler mode of operation for temperature disturbances compensation of direct heating–system water is shown.

  18. Heating and cooling with gas-fired heat-pumps; Heizen und Kuehlen mit Gas-Waermepumpen

    Energy Technology Data Exchange (ETDEWEB)

    Stadelmann, M.

    2008-07-01

    This article takes a look at the use of gas-fired absorption heat-pumps in combined cooling and heating applications. Savings in investments and reduced primary energy consumption along with the resulting lower gas costs are noted. The operation of such 'reversible' systems that use ammonia as a working fluid is briefly described. An installation at a filling station in Taverne, Switzerland, is described. A further installation at a gas utility depot in Givisiez, Switzerland, is also looked at. Here, the gas-powered heat-pump system works together with a solar installation to provide space-heating and cooling as well as hot-water preparation.

  19. Performance Simulation of Microchannel Collector/Evaporator for Solar Heat Pump Water Heater%太阳能热泵热水系统微细通道集热板/蒸发器性能模拟

    Institute of Scientific and Technical Information of China (English)

    周伟; 张小松

    2016-01-01

    本文提出了一种采用微细通道的平板式集热板/蒸发器,它可以从太阳和环境空气二方面获取热量。其主要特点是采用树形分支模型,由两块铝板冷轧吹胀而成,减小了接触热阻,提高了集热板的换热系数。本文建立了该集热板/蒸发器的数学模型并进行了热性能分析,深入研究了不同环境工况条件下该热泵热水系统的性能,包括系统性能系数(COP)、集热板集热效率、加热时间等运行参数的变化特性。结果显示,将150 L水从15 oC加热到50 oC时,系统全年各月的平均COP为4.76,平均加热时间为314 min,环境温度的升高和太阳辐射强度的降低会使集热效率显著增加。%In this paper a new flat-plate collector/evaporator was presented by using microchannel to gain heat from both solar radiation and ambient air. Its main characteristic was using the model of tree branch. The collector/evaporator was made of two pieces of aluminium plates by using the method of cold-rolled huff, which could reduce the contact thermal resistance and improve the heat transfer efficiency of the collector. A simulation model of the collector/evaporator was developed and its thermal performance was analyzed. The performances of heat pump hot water system were evaluated experimentally under different ambients, including heat pump coefficient of performance (COP), heat collecting efficiency and heating time of hot water, etc. The results showed that heating 150 L water with the heat pump from 15 oC to 50 oC, the COP of the whole year was 4.76, and the heating time was 314 min all year around. Meanwhile the heat collecting efficiency increased evidently with the ambient temperature increasing and solar radiation intensity decreasing.

  20. Heat pump system for summer houses if possible combined with solar heating; Varmepumpeanlaeg til fritidshus eventuelt i kombination med solvarme

    Energy Technology Data Exchange (ETDEWEB)

    Ellehauge, K.; Kildemoes, T.; Kristensen, Joern; Bjergen Jensen, T.

    2006-03-15

    Denmark has about 220.000 summer cottages and it is estimated that about 10% of these are for rental. The trend within summer cottages for rental is going towards more and more facilities and intensive rental, and as a consequence of this high energy consumption. A substantial part of the energy use is for heating, i.e. space heating, heating of indoor pool and domestic hot water. Contrary to the other building stock in Denmark summer cottages nearly always use electricity for heating. In the project it is found, that the average yearly electricity use of a summer cottage for rental with indoor pool is about 31.000 kWh. In the project typical energy consumption profiles have been set up from analyses of typical equipment and from simulation of space heat demands in Danish climate. Furthermore a number of heat delivery solutions with heat pumps and solar heating systems have been set up and the performance has been simulated and analysed. As a result of the analyses 2 prototype systems both consisting of an air to air heat pump for space heating and an air to water heat pump for the hot water, the spa and the pool heating has been installed and tested in two summer cottages. There is a good economy in the systems and these are therefore marketed by the project participants, Energi Danmark NRGi (energy utility) and Dansommer (cottage rental company). (au)

  1. Upscaling a district heating system based on biogas cogeneration and heat pumps

    NARCIS (Netherlands)

    van Leeuwen, Richard Pieter; Fink, J.; Smit, Gerardus Johannes Maria; de Wit, Jan B.

    2015-01-01

    The energy supply of the Meppel district Nieuwveense landen is based on biogas cogeneration, district heating, and ground source heat pumps. A centrally located combined heat and power engine (CHP) converts biogas from the municipal wastewater treatment facility into electricity for heat pumps and

  2. Upscaling a district heating system based on biogas cogeneration and heat pumps

    NARCIS (Netherlands)

    Leeuwen, van Richard P.; Fink, Jiří; Wit, de Jan B.; Smit, Gerard J.M.

    2015-01-01

    The energy supply of the Meppel district Nieuwveense landen is based on biogas cogeneration, district heating, and ground source heat pumps. A centrally located combined heat and power engine (CHP) converts biogas from the municipal wastewater treatment facility into electricity for heat pumps and h

  3. Upscaling a district heating system based on biogas cogeneration and heat pumps

    NARCIS (Netherlands)

    van Leeuwen, Richard Pieter; Fink, J.; Smit, Gerardus Johannes Maria; de Wit, Jan B.

    2015-01-01

    The energy supply of the Meppel district Nieuwveense landen is based on biogas cogeneration, district heating, and ground source heat pumps. A centrally located combined heat and power engine (CHP) converts biogas from the municipal wastewater treatment facility into electricity for heat pumps and h

  4. Energy system investment model incorporating heat pumps with thermal storage in buildings and buffer tanks

    DEFF Research Database (Denmark)

    Hedegaard, Karsten; Balyk, Olexandr

    2013-01-01

    options: passive heat storage in the building structure via radiator heating, active heat storage in concrete floors via floor heating, and use of thermal storage tanks for space heating and hot water. It is shown that the model is well qualified for analysing possibilities and system benefits...... be taken into account. In this study, we present a model that facilitates analysing individual heat pumps and complementing heat storages in integration with the energy system, while optimising both investments and operation. The model incorporates thermal building dynamics and covers various heat storage...

  5. Analysis of Fuel Cell Driven Ground Source Heat Pump Systems in Community Buildings

    Directory of Open Access Journals (Sweden)

    Jong-Keun Shin

    2013-05-01

    Full Text Available In the present study, a fuel cell driven ground source heat pump (GSHP system is applied in a community building and heat pump system performance is analyzed by computational methods. Conduction heat transfer between the brine pipe and ground is analyzed by TEACH code in order to predict the performance of the heat pump system. The predicted coefficient of performance (COP of the heat pump system and the energy cost were compared with the variation of the location of the objective building, the water saturation rate of the soil, and the driven powers of the heat pump system. Compared to the late-night electricity driven system, a significant reduction of energy cost can be accomplished by employing the fuel cell driven heat pump system. This is due to the low cost of electricity production of the fuel cell system and to the application of the recovered waste heat generated during the electricity production process to the heating of the community building.

  6. Absorption heat pump with an average efficiency of 140%. Absorptiewarmtepomp haalt gemiddeld rendement van 140%

    Energy Technology Data Exchange (ETDEWEB)

    Langreck, J. (Colibri BV, Landgraaf (Netherlands))

    1994-09-01

    A description is given of a new type of absorption heat pump in which ammonia/water is applied as the working fluid. With the first sample in the provincial government building in Maastricht, Netherlands, and efficiency of 140% has been realized. A brief overview is given of the costs of and the market for this new type of heat pump. 2 figs., 1 ill., 3 tabs., 1 ref.

  7. COMPARATIVE STUDY AMONG HYBRID GROUND SOURCE HEAT PUMP SYSTEM, COMPLETE GROUND SOURCE HEAT PUMP AND CONVENTIONAL HVAC SYSTEM

    Energy Technology Data Exchange (ETDEWEB)

    Jiang Zhu; Yong X. Tao

    2011-11-01

    In this paper, a hotel with hybrid geothermal heat pump system (HyGSHP) in the Pensacola is selected and simulated by the transient simulation software package TRNSYS [1]. To verify the simulation results, the validations are conducted by using the monthly average entering water temperature, monthly facility consumption data, and etc. And three types of HVAC systems are compared based on the same building model and HVAC system capacity. The results are presented to show the advantages and disadvantages of HyGSHP compared with the other two systems in terms of energy consumptions, life cycle cost analysis.

  8. Development of a jet pump-assisted arterial heat pipe

    Science.gov (United States)

    Bienert, W. B.; Ducao, A. S.; Trimmer, D. S.

    1977-01-01

    The development of a jet pump assisted arterial heat pipe is described. The concept utilizes a built-in capillary driven jet pump to remove vapor and gas from the artery and to prime it. The continuous pumping action also prevents depriming during operation of the heat pipe. The concept is applicable to fixed conductance and gas loaded variable conductance heat pipes. A theoretical model for the jet pump assisted arterial heat pipe is presented. The model was used to design a prototype for laboratory demonstration. The 1.2 m long heat pipe was designed to transport 500 watts and to prime at an adverse elevation of up to 1.3 cm. The test results were in good agreement with the theoretical predictions. The heat pipe carried as much as 540 watts and was able to prime up to 1.9 cm. Introduction of a considerable amount of noncondensible gas had no adverse effect on the priming capability.

  9. Design of Control System of Parallel Solar Assisted Heat Pump Water Heater%并联式太阳能热泵热水器控制系统设计

    Institute of Scientific and Technical Information of China (English)

    张建成; 吴永明; 苗文凭

    2012-01-01

    阐述了并联式太阳热泵热水器是最易受推广使用的太阳能热泵热水器类型;针对23目前并联式太阳能热泵热水器存在的集成化控制问题,分析了并联式太阳热泵热水器控制系统的控制要求,采用水位、温差与时间相结合的控制方法,以ATmega48单片机为核心,研究了控制系统的工作原理、硬件结构及控制数据流程;系统能够根据天气、水温等不同情况自动选择太阳能机组或空气能热泵机组来制取热水,并且具有主要设备的故障自诊断功能、压缩机延时保护功能及智能化霜功能,提高了该热水器的稳定性和低温制热效率;测试结果表明:使用该集成系统后,系统平均能源利用率提高了约23%.%Among all the solar assisted heat pump water heater, the paralle type is the most easily promoted. According to the integrated problem that exists in the control of the parallel solar assisted heat pump water heater, on the basis of analyzing requirements of the control system of the parallel solar assisted heat pump water heater, the control method associating with water-level, difference in temperature and time is applied. The realization principle, hardware structure and controlling data flow of the control system are studied based on AT-mega48. The system can select automatically solar-energy or air-energy heat -pump to make hot water according to weather and water temperature. Combined with the functions of fault self -diagnosis for key facilities, delay protection for compressor and automatically defrosting, the control system can improve the stability and thermal efficiency of the water heater under the low temperature. The results show that 23%of the average energy efficiency have been improved by using the integrated control system.

  10. Operation Performance of Air Source Heat Pump System for Space Heating in Tianjin

    Institute of Scientific and Technical Information of China (English)

    ZHAO Jun; CHEN Yan; QU Hang; LI Xinguo

    2007-01-01

    An air source heat pump system (ASHPS) used in an office building is set up and studied experimentally. Its operating performance in winter is evaluated based on test data and a comparative discussion is given on the effect of climate conditions and heating load ratio on the operation behavior.Then heating capacity variation caused by evaporator frosting is analyzed as well. Finally, the defrosting parameters and the technical feasibility are studied for a constant heating demand. The experimental results indicate that both the outlet water temperature drop and the system COP should be taken into account when setting defrosting parameters, and ASHPS is a viable technology for space heating and hotwater production in winter in Tianjin, which can maintain the room temperature above 19 ℃ when the outdoor temperature is -2 ℃.

  11. Heat pumps in nursing homes; Warmtepompen in verzorgingshuizen

    Energy Technology Data Exchange (ETDEWEB)

    Dieleman, M. [Erbeko raadgevende ingenieurs, Hilversum (Netherlands)

    1996-04-01

    The most important options for the sector nursing homes to save 20-30% energy are the combined generation of heat and power (CHP or cogeneration) and the use of heat pumps. Cogeneration is cost-effective for a natural gas consumption of 200,000 m{sup 3} per year. The heat pump is a good option for both small and large nursing homes. 2 tabs.

  12. Domestic Heating and Cooling and Hot Water Supply System Based on Heat Pumps and Solar Energy%基于热泵和太阳能的住宅供暖供冷供生活热水三联供系统研究

    Institute of Scientific and Technical Information of China (English)

    魏海翔; 梁镇杰; 梁海珍; 刘翠华

    2014-01-01

    Residential heating and cooling water supply system for combined based on heat pumps and solar is a line with the social sustainable development, energy saving and environmental protection technical measures, it is a major breakthrough in air heat pump and solar energy industries. The system DC inverter air heat pump as the core,combined with solar energy,electricity and other energy to residential heating, cooling and domestic hot water provided, focus on solving the DC inverter air heat pump to residential and efficient heating, cooling, hot for life water, and solar and other alternative energy linkage, for residential heating cooling and domestic hot water systems integration and technology and other key technology issues.%基于热泵和太阳能的住宅供暖供冷供生活热水三联供系统是一项符合社会可持续发展的,节能环保的技术措施。该系统以直流变频空气能热泵为核心,结合太阳能、电能及其他能源,向住宅供暖、供冷及提供生活热水,着重解决了直流变频空气能热泵向住宅高效供暖、供冷、供生活热水,和太阳能及其他备用能源的联动,面向住宅供暖冷及生活热水的系统集成关键技术及工艺等问题。

  13. Optimal usage of low temperature heat sources to supply district heating by heat pumps

    DEFF Research Database (Denmark)

    Pieper, Henrik; Ommen, Torben Schmidt; Markussen, Wiebke Brix

    2017-01-01

    This paper presents a theoretical study on the optimal usage of different low temperature heat sources to supply district heating by heat pumps. The study is based on data for the Copenhagen region. The heat sources were prioritized based on the coefficient of performance calculated for each hour....... Groundwater, seawater and air heat sources were compared with each other as well as to a scenario consisting of a combination of these heat sources. In addition, base load and peak load units were included. Characteristic parameters were the coefficient of performance, the number of full load hours...

  14. Space Station Water Processor Process Pump

    Science.gov (United States)

    Parker, David

    1995-01-01

    This report presents the results of the development program conducted under contract NAS8-38250-12 related to the International Space Station (ISS) Water Processor (WP) Process Pump. The results of the Process Pumps evaluation conducted on this program indicates that further development is required in order to achieve the performance and life requirements for the ISSWP.

  15. Thermodynamic analysis of a thermally operated cascade sorption heat pump for continuous cold generation

    OpenAIRE

    P. Muthukumar, D.V.N. Lakshmi

    2013-01-01

    In this paper, the thermodynamic analysis of a cascade sorption system consists of a two-stage metal hydride heat pump as topping cycle and a single-stage lithium bromide water system as bottom cycle is presented. The effects of various operating temperatures such as driving heat, heat release and refrigeration temperatures, and design parameters such as ratio of metal hydride mass to reactor mass and sensible heat exchange factor on the combined coefficient of performance (COP) of the cascad...

  16. Installation of potable water supply and heat supply at base of subsoil water

    Directory of Open Access Journals (Sweden)

    Denysova Alla Evseevna

    2016-01-01

    Full Text Available Removal of groundwater with further use of it for potable water supply and heat supply with the use of heat pump is an important problem. A new revolutionary approach to the decision of energy and water saving that provides rational accommodation of groundwater boreholes ensuring the required flow rate of water through the heat pump evaporator with simultaneously high intensity of heat exchange process is proposed. The method of calculation which allows determining the necessary depth of borehole, quantity of boreholes, in consideration of flow rate and temperature of subsoil water determining capacity of heat pump installation is worked out.

  17. Installation of potable water supply and heat supply at base of subsoil water

    Directory of Open Access Journals (Sweden)

    Denysova Alla Evseevna

    2016-01-01

    Full Text Available Removal of groundwater with further use of it for potable water supply and heat supply with the use of heat pump is an important problem. A new revolutionary approach to the decision of energy and water saving that provides rational accommodation of groundwater boreholes ensuring the required flow rate of water through the heat pump evaporator with simultaneously high intensity of heat exchange process is proposed. The method of calculation which allows determining the necessary depth of borehole, quantity of boreholes, in consideration of flow rate and temperature of subsoil water determining capacity of heat pump installation is worked out.

  18. High temperature heat pumps for industrial cooling; Hoejtemperatur varmepumper til industriel koeling

    Energy Technology Data Exchange (ETDEWEB)

    Rasmussen, Lars; Nielsen, Jacob [Advansor A/S, Aarhus (Denmark); Kronborg, H. [Cronborg, Holstebro (Denmark); Skouenborg, K. [Jensens Koekken, Struer (Denmark)

    2013-03-15

    This report deals with theoretical analysis of various types of integration of heat pumps in the industry, as well as a demonstration plant that serves the project's practical execution. The report describes the system integration between heat pumps and existing industrial cooling systems. Ammonia plants in industry are estimated to have an allocation of 85%, which is why only an analysis of this type of installation as surplus heat supplier is included in this report. In contrast, heat pumps with both CO{sub 2} and Isobutane as the refrigerant are analysed, since these are the interesting coolants for generating high temperature heat. It can be seen through the project that the combination of heat pump with existing cooling installations may produce favorable situations where the efficiency of the heat pump is extremely high while at the same time electricity and water consumption for the cooling system is reduced. The analysis reflects that CO{sub 2} is preferred over Isobutane in the cases where a high level of temperature boost is desired, whereas Isobutane is preferable at low level of temperature boost. In the demonstration project, the report shows that the heat pump alone has a COP of 4.1, while the achieved COP is 5.5 when by considering the system as a whole. In addition to increased performance the solution profits by having a reduction in CO{sub 2} emissions of 81 tons/year and a saving of 470,000 DKK/year. (LN)

  19. Solar Assisted Ground Source Heat Pump Performance in Nearly Zero Energy Building in Baltic Countries

    Science.gov (United States)

    Januševičius, Karolis; Streckienė, Giedrė

    2013-12-01

    In near zero energy buildings (NZEB) built in Baltic countries, heat production systems meet the challenge of large share domestic hot water demand and high required heating capacity. Due to passive solar design, cooling demand in residential buildings also needs an assessment and solution. Heat pump systems are a widespread solution to reduce energy use. A combination of heat pump and solar thermal collectors helps to meet standard requirements and increases the share of renewable energy use in total energy balance of country. The presented paper describes a simulation study of solar assisted heat pump systems carried out in TRNSYS. The purpose of this simulation was to investigate how the performance of a solar assisted heat pump combination varies in near zero energy building. Results of three systems were compared to autonomous (independent) systems simulated performance. Different solar assisted heat pump design solutions with serial and parallel solar thermal collector connections to the heat pump loop were modelled and a passive cooling possibility was assessed. Simulations were performed for three Baltic countries: Lithuania, Latvia and Estonia.

  20. Investigation on chemical heat pump using calcium-chloride; Enka calcium no suiwa dassui hanno wo mochiita solar chemical heat pump ni kansuru kenkyu

    Energy Technology Data Exchange (ETDEWEB)

    Fujii, I.; Arai, T.; Saito, Y. [Meiji University, Tokyo (Japan)

    1997-11-25

    With an objective of developing a room heating system utilizing a solar chemical heat pump, an experimental system was fabricated to evaluate its performance. Steam was employed as a working gas, and for a reaction material, calcium-chloride was used, which has a reaction temperature zone permitting safe use and fitting the purpose among other hydrate systems and has high standard enthalpy in hydration. Water was used as a solar heat transferring medium. The system operates under the following principle: a container I is filled with hydrated salt and a container II with water, the two containers being linked with a pipe interposed with a valve; heat is inputted and outputted by performing charging and discharging alternately; and the role of a heat pump is played by deriving from environment the heat of water evaporation in the container II during discharging. The COP must take into account the electric power consumption of the water circulation pump to transfer solar heat. A COP of 0.256 was derived as a result of the experiment. 3 refs., 5 figs.

  1. Ground-source Heat Pump Barometer

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2011-09-15

    The double whammy dealt by the economic crisis and housing slump has stifled expansion of the ground-source heat pump market in many European countries. The European Union market contracted for the second year running (by 2.9% between 2009 and 2010), and this despite the fact that more than 100,000 units were sold over the twelve-month period, taking the number of installed units past the one million mark. [French] La crise economique ainsi que la crise immobiliere qui touchent de nombreux pays europeens ne facilitent pas l'essor du marche de la pompe a chaleur geothermique. Pour la deuxieme annee consecutive, le marche de l'union europeenne est en baisse (-2,9 % entre 2009 et 2010). il parvient tout de meme a se maintenir au-dessus des 100 000 unites vendues par an, ce qui lui permet de depasser pour la premiere fois le cap du million d'unites installees.

  2. Super heat pump energy accumulation system

    Energy Technology Data Exchange (ETDEWEB)

    1989-08-20

    The SHP is a project for which NEDO is commissioned as a part of the Moonlight Project by MITI and has developed since 1985. This report introduced mainly the practical results(trial operation study of the 100kW class bench scale plant) in 1988 fiscal year and the present situation of SHP technical development. Further, this report introduced the estimation of the effects of carbon dioxide decrease and energy saving on the global warmimg up. On the bench scale experiment, the 100kW class compressive heat pump of super high performance and a 10Mcal class high density chemical energy storing technique between higher temperature(100{sup 0}C or more) and cooler temperature(10{sup 0}C or less) were established. The energy saving effect for business, industry and cooling energy in Japan by SHP is estimated to be 205kl(oil)/year in 2000 and CO{sub 2} reducing effect is estimated to be about 820,000tons/Year. 2 refs., 4figs.

  3. Performance prediction of an absorption heat pump for utilization in industry

    Energy Technology Data Exchange (ETDEWEB)

    Lazzarin, R.M.; Longo, G.A. (Padua Univ. (Italy))

    1994-01-01

    Recently, an absorption heat pump has been put on the market for industrial utilization. It is a H[sub 2]O-LiBr absorption machine which heats up water to 90[sup o]C with cold source at 40[sup o]C. The capacity and Coefficient of performance (COP) of the machine have been studied by a computer program as a function of cold source temperature and heated fluid temperature. Also, a comparison with a compression heat pump is reported. (Author)

  4. Empirical Platform Data Analysis to Investigate how Heat Pumps Operate in Real-Life Conditions

    DEFF Research Database (Denmark)

    Carmo, Carolina; Elmegaard, Brian; Nielsen, Mads Pagh

    2015-01-01

    Heat pumps have been widely acknowledged, by academia and industry, as highly efficient thermal energy technologies, for space heating and domestic hot water production. However, there is a lack of information about real performance in residential single family houses with active participation...... heat pump configurations are considered depending on source (ground or air) and sink (radiators, floor heating and/or combined systems). This unique study intends to point out the benefits and limitations of such technologies in terms of energy efficiency and comfort delivery, as well as investigating...

  5. Solar-assisted heat pumps: impact of evaporator characteristics on performance

    Energy Technology Data Exchange (ETDEWEB)

    Catan, M.A.

    1982-03-01

    Five water-refrigerant heat exchangers were tested as part of a program of experimental studies of solar-assisted heat pump (SAHP) components and controls. The aim of this work is to establish ways of improving on the benchmark designs of two prototype SAHPs, one each built by Northrup Incorporated and Lennox Industries Incorporated under contract to the US Department of Energy (DOE). The performance of a water source heat pump, employing any of these evaporators, can be projected using these data, in conjunction with appropriate data pertaining to the rest of the heat pump. Thus, the impact of the evaporator's characteristics on the heat pump performance as a whole may be assessed. The necessary supplementary data may be obtained from compressor curves and condenser performance data, or from test data from a heat pump for which substitution of one of the evaporators considered in this report is contemplated. The steady state performance of the Northrup prototype SAHP employing each of the heat exchangers tested is projected using these test data. The projections of coefficient of performance (COP) versus entering water temperature performance are presented along with the original test data for comparison.

  6. Improvements of high-temperature drying heat pumps

    Energy Technology Data Exchange (ETDEWEB)

    Minea, V. [Hydro-Quebec Research Institute, Laboratoire des technologies de l' energie (LTE), 600, avenue de la Montagne, Shawinigan G9N 7N5 (Canada)

    2010-01-15

    Inadequate integration and/or inappropriate operating parameters of heat pump dryers may lead to troubles as too high/low discharge/suction pressures, low dehumidification efficiency and even mechanical damage to the compressor. This paper will help fix a number of common design errors and/or omissions, and suggests original control methods to avoid undesirable operational incidents and improve overall energy performance of high-temperature drying heat pumps. The scope is to provide normal and safe operating conditions, and thus accelerate the implementation of industrial drying heat pumps. (author)

  7. Stochastic pumping of heat: approaching the Carnot efficiency.

    Science.gov (United States)

    Segal, Dvira

    2008-12-31

    Random noise can generate a unidirectional heat current across asymmetric nano-objects in the absence (or against) a temperature gradient. We present a minimal model for a molecular-level stochastic heat pump that may operate arbitrarily close to the Carnot efficiency. The model consists a fluctuating molecular unit coupled to two solids characterized by distinct phonon spectral properties. Heat pumping persists for a broad range of system and bath parameters. Furthermore, by filtering the reservoirs' phonons the pump efficiency can approach the Carnot limit.

  8. Jet pump-drive system for heat removal

    Science.gov (United States)

    French, James R. (Inventor)

    1987-01-01

    The invention does away with the necessity of moving parts such as a check valve in a nuclear reactor cooling system. Instead, a jet pump, in combination with a TEMP, is employed to assure safe cooling of a nuclear reactor after shutdown. A main flow exists for a reactor coolant. A point of withdrawal is provided for a secondary flow. A TEMP, responsive to the heat from said coolant in the secondary flow path, automatically pumps said withdrawn coolant to a higher pressure and thus higher velocity compared to the main flow. The high velocity coolant is applied as a driver flow for the jet pump which has a main flow chamber located in the main flow circulation pump. Upon nuclear shutdown and loss of power for the main reactor pumping system, the TEMP/jet pump combination continues to boost the coolant flow in the direction it is already circulating. During the decay time for the nuclear reactor, the jet pump keeps running until the coolant temperature drops to a lower and safe temperature where the heat is no longer a problem. At this lower temperature, the TEMP/jet pump combination ceases its circulation boosting operation. When the nuclear reactor is restarted and the coolant again exceeds the lower temperature setting, the TEMP/jet pump automatically resumes operation. The TEMP/jet pump combination is thus automatic, self-regulating and provides an emergency pumping system free of moving parts.

  9. Thermodynamic analysis of geothermal heat pump during the cold season

    Science.gov (United States)

    Dumitrașcu, G.; Dumencu, A.; Horbaniuc, B.; Atanasiu, M. V.

    2016-08-01

    The paper is analysing the performances (COP, power and, heating heat rate function of time) for a ground-coupled heat pump that is used to heat a space during winter, for a period of 180 days. The analysis purpose is to evaluate the time based changes in values of COP and, energy transfers of a geothermal heat pump, considering a scenario for the variation of the ambient temperature in time and an analytical solution for the time dependence of the soil one. The temperatures and the energy transfer rates were determined on the basis of the irreversible entropy balance equation.

  10. CARBON DIOXIDE HEAT PUMP IN TRANSCRITICAL CYCLE FOR INSTALLATION FOR PASTEURIZATION AND COOLING OF DAIRY FOODS

    Directory of Open Access Journals (Sweden)

    Sit M.L.

    2012-08-01

    Full Text Available There are elaborated schemes of installations for pasteurization and cooling of dairy foods with heat pumps introduced in there schemes. Schemes distinguish oneself by the possibility of using of additional useful heat for getting hot water for technological purposes.

  11. A flexible and low cost experimental stand for air source heat pump for Smart Buildings

    DEFF Research Database (Denmark)

    Crăciun, Vasile S.; Bojesen, Carsten; Blarke, Morten

    2012-01-01

    prices. A significant part of this challenge may be dealt with in the way space heating, space cooling, and domestic hot water production which is provided to residential and commercial buildings. Air source heat pumps (ASHP) are widely used conversion technologies for providing building thermal energy...

  12. Metal hydride heat pump engineering demonstration and evaluation model

    Science.gov (United States)

    Lynch, Franklin E.

    1993-01-01

    Future generations of portable life support systems (PLSS's) for space suites (extravehicular mobility units or EMU's) may require regenerable nonventing thermal sinks (RNTS's). For purposes of mobility, a PLSS must be as light and compact as possible. Previous venting PLSS's have employed water sublimators to reject metabolic and equipment heat from EMU's. It is desirable for long-duration future space missions to minimize the use of water and other consumables that need to be periodically resupplied. The emission of water vapor also interferes with some types of instrumentation that might be used in future space exploration. The test article is a type of RNTS based on a metal hydride heat pump (MHHP). The task of reservicing EMU's after use must be made less demanding in terms of time, procedures, and equipment. The capability for quick turnaround post-EVA servicing (30 minutes) is a challenging requirement for many of the RNTS options. The MHHP is a very simple option that can be regenerated in the airlock within the 30 minute limit by the application of a heating source and a cooling sink. In addition, advanced PLSS's must provide a greater degree of automatic control, relieving astronauts of the need to manually adjust temperatures in their liquid cooled ventilation garments (LCVG's). The MHHP includes automatic coolant controls with the ability to follow thermal load swings from minimum to maximum in seconds. The MHHP includes a coolant loop subsystem with pump and controls, regeneration equipment for post-EVA servicing, and a PC-based data acquisition and control system (DACS).

  13. 大型吸收式热泵应用于火电厂回收余热供热的试验研究%The Experiment Study on Waste Heat Recovery from Circulating Water in Thermal Power Plant Using Large Absorption Heat Pump

    Institute of Scientific and Technical Information of China (English)

    周崇波; 俞聪; 郭栋; 丁贯林

    2013-01-01

    An experiment on waste heat recovery thermal characteristics from circulating water in 125MW and 300MW thermal power plants using large absorption heat pump is conducted. The steam pressure, the temperature of the backwater from heat-supply network, the inlet circulating water temperature of the large absorption heat pump system are analyzed under other external conditions and different parameters. Then the effects of main external parameters on heating capacity, the recovery of residual heat, energy efficiency ratio and other important indicators in the large absorption heat pump are quantitatively discussed . The conclusion provide the firsthand information for the design of the waste heat recovery engineering and regular operation of large absorption heat pump.%针对已在125MW及300MW等级火电厂中投产的大型吸收式热泵系统的变工况热力特性进行试验测试,并分析其试验数据,对吸收式热泵系统在驱动蒸汽压力、热网水回水温度、余热水进水温度等主要外部条件和参数变化条件下的运行指标进行了测试和分析,从而获得了这些主要外部参数改变对吸收式热泵制热能力、余热回收量、能效比等重要指标的定量影响.该试验结果为采用大型吸收式热泵系统进行电厂冷凝热回收供热改造工程的初期设计及投产后的优化运行提供了第一手参考资料.

  14. AUTOMATIC CONTROL SYSTEM OF HEAT PUMP STATION GAS COOLER AT THE WIDE RANGE OF HEAT LOAD

    Directory of Open Access Journals (Sweden)

    Juravleov A.A.

    2008-08-01

    Full Text Available There is examined the structure the of control system of gas cooler of heat pump station, which uses the carbon dioxide as the working fluid in the transctitical thermodynamical cycle. It is analiyed the structure of the complex: heat pump station – district heating system.

  15. Wind power integration using individual heat pumps – Analysis of different heat storage options

    DEFF Research Database (Denmark)

    Hedegaard, Karsten; Mathiesen, Brian Vad; Lund, Henrik

    2012-01-01

    Significant installations of individual heat pumps are expected in future energy systems due to their economic competitiveness. This case study of the Danish energy system in 2020 with 50% wind power shows that individual heat pumps and heat storages can contribute to the integration of wind power...... reductions in excess electricity production and fuel consumption than heat accumulation tanks. Moreover, passive heat storage is found to be significantly more cost-effective than heat accumulation tanks. In terms of reducing fuel consumption of the energy system, the installation of heat pumps is the most...... important step. Adding heat storages only moderately reduces the fuel consumption. Model development has been made to facilitate a technical optimisation of individual heat pumps and heat storages in integration with the energy system....

  16. Optimization of a commercial, medium size, reversible heat pump for use with propane

    Energy Technology Data Exchange (ETDEWEB)

    Corberan, J.M. [Dept. of Applied Thermodynamics, Univ. Politecnica de Valencia (Spain); Urchueguia, J.F. [Dept. of Applied Physics, Univ. Politecnica de Valencia (Spain); Conde, M. [Manuel Conde Eng., Zuerich (Switzerland); Setaro, T. [Ente per le Nuove Tecnologie, l' Energia e l' Ambiente (ENEA), Energy Dept., S.M. di Galeria (Italy); Sartori, L.; Zorzin, A. [Alfa Laval-Artec Spa, Alonte (Italy); Granryd, E.; Palm, B. [Kungl Tekniska Hokskolan, Stockholm (Sweden); Saez, J.; Ramos, A. [Cia. Industrial de Aplicaciones Tecnicas S.A., Cordoba (Spain); Blas, J. de [Asociacion Espanola para la Diagnosis y la Investigacion en Energia (AEDIE), Madrid (Spain)

    1999-07-01

    In this paper we give a summarized description of the HEAHP/J3 project, currently running under the support of the European Commission. In the frame of this project, a medium size reversible air to water heat pump for use with propane (R290) and appropriate for south European countries - in which refrigeration is a strong demand - is currently being developed by the partners. The starting point is a 20 kW, R22, commercial heat pump from CIATESA, a major Spanish heat pump manufacturer, which will be adapted and optimized for the use of propane as refrigerant. Computer simulations are under development aiming to identify the improvements and/or modifications needed in the components to ensure safe use and high efficiency, in terms of COP, of the heat pump. The scope of these models is to assist the optimization and design of the different elements of the heat pump. To aid the adjustment of these models while generating a large database covering the behavior of propane as a refrigerant, individualized characterization experiments of all pump components will be performed. Both aspects, modeling and measurements, are issued to converge in the reduction of size of all components resulting from the use of efficient extended surfaces in the heat exchangers and (for a given refrigeration or heat capacity) in the improvement of overall efficiency through the appropriate selection or adaptation, as far as possible, of the compressor. (orig.)

  17. 辛集市以地热弃水为热源的热泵供暖方式探讨%Heating mode of geothermal abandoned water-source heat pump system in Xinji City

    Institute of Scientific and Technical Information of China (English)

    牛利敏; 孟冲; 毛晓峰; 兰文治; 田建章; 李红艳

    2011-01-01

    Presents the application of the system to a residential quarter in Xinji. Tests the application effect and the COP of heat pump units and the heat pump system. Analyses and evaluates the energy saving property and economic efficiency of the system based on the field test data, providing reference for other similar applications.%介绍了辛集某小区地热弃水热泵供暖系统的应用情况,并对其应用效果、热泵机组的性能、热泵系统的性能进行了测试,依据测试结果对其节能性、经济性进行了分析评价,供其他地热弃水热泵供暖项目参考.

  18. 广州亚运城太阳能水源热泵项目设计要点介绍%Introduction of the design points of Guangzhou Asian Games Town solar hot water and water source heat pump project

    Institute of Scientific and Technical Information of China (English)

    王耀堂; 王则慧; 董立; 赵世明; 刘振印

    2011-01-01

    Guangzhou Asian Games Town is located in Panyu district of Guangzhou City, including athlete village, media village, technical official village, logistic service village, gyms village, and Asian Games Park. As the initialization district of new city construction, Asian Games Town is positioned as medium and high level residential community and regional service center with comprehensive facilities, and will be used as Asian Games Village in 2010 for the 16th Asian Games. As an important special technology project, the Asian Games Town solar energy and water source heat pump project were designed, constructed and managed solely, and this system would supply the Asian Games Town residential buildings domestic hot water and partial singular building air condition cold source. The engineering background, general situation and system design principles of Guangzhou Asian Games Town solar energy and water source heat pump project were introduced, and the engineering project design content and difficult problems were also summarized.%广州亚运城位于广州市番禺区,分为运动员村、媒体村、技术官员村、后勤服务区、体育馆区及亚运公园六大部分.亚运城作为新城建设的启动区,定位为配套完善的中高档居住社区及区域服务中心,2010年作为第16届亚运会亚运村使用.亚运城太阳能和水源热泵利用工程作为亚运城重大技术专项进行单独设计、施工和运行管理,系统集中供应亚运城居住建筑生活热水和部分单体建筑空调冷源.介绍了广州亚运城太阳能水源热泵项目的工程背景、工程概况和系统设计原则,总结了主要工程设计内容和难点问题.

  19. 基于机械蒸汽再压缩热泵的DMAC水溶液浓缩工艺模拟%Concentration Process Simulation of DMAC Water Solution Based on the MVR Heat Pump

    Institute of Scientific and Technical Information of China (English)

    侯涛

    2013-01-01

    分析了蒸汽机械再压缩(MVR)热泵浓缩工艺的节能原理和适用工况,并以DMAC水溶液的浓缩为研究对象,提出了三效MVR热泵蒸馏浓缩工艺.采用Aspen Plus过程模拟软件中的Compr压缩机模块和Radffac精馏模块,并以能耗最低为目标函数,对三效MVR热泵蒸馏浓缩工艺和三效蒸馏蒸发浓缩工艺分别进行了模拟与优化,得到了合适的工艺操作参数.研究结果表明,与三效蒸馏蒸发浓缩工艺相比,三效MVR热泵蒸馏浓缩工艺节能约68.7%,其平均能效比COP值为0.863.多效MVR热泵蒸馏浓缩工艺具有较大的经济优势.%The energy-saving principle and applied working conditions of heat pump concentration technology of mechanical vapor recompression (MVR) is analyzed.The object of this study is the concentration of DMAC water solution,and the triple effect MVR heat pump distillation concentration process is introduced,simulating Compr compressor module and Radfrac distillation module by Aspen plus,with minimum energy consumption as the objective function,optimized triple effect MVR heat pump distillation concentration process and triple effect distillation evaporation and concentration process,the suitable technical parameters is established.The research results showed that the triple-effect MVR heat pump distillation and concentration process could save energy by 68.7% compared with the triple effect distillation evaporation and concentration process,the average COP reached 0.863,and the multi-effect MVR heat pump distillation concentration technology had great economic advantages.

  20. Long-Term Operating Characteristics of Ground-Coupled Heat Pump Systems with Variable Water Volume%土壤源热泵变流量系统的长期运行特性研究

    Institute of Scientific and Technical Information of China (English)

    戴霖姗; 刘金祥; 盛建军; 陈高峰; 章亚武

    2014-01-01

    The variable-speed pump model of TRNSYS transient system simulation program is opti-mized, and the new model is validated with the measured data. The system models of constant flow rate and several different variable flow rates are established, running the system models for 15 years. The energy consumption of water pump and heat pump are expounded based on the results of simulation. According to the results of simulation, we can also discuss the average temperature of the heat storage.%在TRNSYS仿真模拟软件的基础上,对其中的变速泵模拟进行了优化,并用实验值验证模型。分别建立定流量和变流量系统的仿真模型,并进行长期模拟。模拟结果得到15年的水泵、热泵机组全年的能耗,分别讨论了制冷期、制热期的能耗情况,并从15年的土壤平均温度变化讨论定流量与变流量对埋管区域热环境的影响。