WorldWideScience

Sample records for water damaged building

  1. Vocal cord dysfunction related to water-damaged buildings.

    Science.gov (United States)

    Cummings, Kristin J; Fink, Jordan N; Vasudev, Monica; Piacitelli, Chris; Kreiss, Kathleen

    2013-01-01

    Vocal cord dysfunction (VCD) is the intermittent paradoxical adduction of the vocal cords during respiration, resulting in variable upper airway obstruction. Exposure to damp indoor environments is associated with adverse respiratory health outcomes, including asthma, but its role in the development of VCD is not well described. We describe the spectrum of respiratory illness in occupants of 2 water-damaged office buildings. The National Institute for Occupational Safety and Health conducted a health hazard evaluation that included interviews with managers, a maintenance officer, a remediation specialist who had evaluated the 2 buildings, employees, and consulting physicians. In addition, medical records and reports of building evaluations were reviewed. Diagnostic evaluations for VCD had been conducted at the Asthma and Allergy Center of the Medical College of Wisconsin. Two cases of VCD were temporally related to occupancy of water-damaged buildings. The patients experienced cough, chest tightness, dyspnea, wheezing, and hoarseness when in the buildings. Spirometry was normal. Methacholine challenge did not show bronchial hyperreactivity but did elicit symptoms of VCD and inspiratory flow-volume loop truncation. Direct laryngoscopy revealed vocal cord adduction during inspiration. Coworkers developed upper and lower respiratory symptoms; their diagnoses included sinusitis and asthma, consistent with recognized effects of exposure to indoor dampness. Building evaluations provided evidence of water damage and mold growth. VCD can occur with exposure to water-damaged buildings and should be considered in exposed patients with asthma-like symptoms. Published by Elsevier Inc.

  2. Decision Tree Analysis Of Processes Generating Water-Related Building Damage : A Case Study In Rotterdam, The Netherlands

    NARCIS (Netherlands)

    Spekkers, M.H.; Clemens, F.H.L.R.; ten Veldhuis, J.A.E.; Piasecki, M

    2014-01-01

    The objective of this study was to identify the main failure mechanisms behind water-related building damage and to investigate to what extent these processes are related to characteristics of buildings and rainfall events. Results are based on the mining of property level insurance damage data, for

  3. Flood vulnerability assessment of residential buildings by explicit damage process modelling

    DEFF Research Database (Denmark)

    Custer, Rocco; Nishijima, Kazuyoshi

    2015-01-01

    The present paper introduces a vulnerability modelling approach for residential buildings in flood. The modelling approach explicitly considers relevant damage processes, i.e. water infiltration into the building, mechanical failure of components in the building envelope and damage from water...

  4. Optimal choice: assessing the probability of additional damage to buildings caused by water level changes of larger areas

    Science.gov (United States)

    Bijnagte, J. L.; Luger, D.

    2012-12-01

    In the Northern parts of the Netherlands exploration of natural gas reservoirs causes subsidence over large areas. As a consequence, the water levels in canals and polders have to be adjusted over time in order to keep the groundwater levels at a constant depth relative to the surface level. In the middle of the subsidence area it is relatively easy to follow the settlements by a uniform lowering of the water level. This would however result in a relative lowering of the groundwater table at the edges of the subsidence area. Given the presence of soft compressible soils, this would result in induced settlements. For buildings in these areas this will increase the chance of damage. A major design challenge lies therefore in the optimisation of the use of compartments. The more compartments the higher the cost therefore the aim is to make compartments in the water management system that are as large as possible without causing inadmissible damage to buildings. In order to asses expected damage from different use of compartments three tools are needed. The first is a generally accepted method of damage determination, the second a method to determine the contribution to damage of a new influence, e.g. a groundwater table change. Third, and perhaps most importantly, a method is needed to evaluate effects not for single buildings but for larger areas. The first need is covered by established damage criteria like those of Burland & Wroth or Boscardin & Cording. Up until now the second and the third have been problematic. This paper presents a method which enables to assign a contribution to the probability of damage of various recognised mechanisms such as soil and foundation inhomogeneity, uneven loading, ground water level changes. Shallow subsidence due to peat oxidation and deep subsidence due to reservoir depletion can be combined. In order to address the third issue: evaluation of effects for larger areas, the method uses a probabilistic approach. Apart from a

  5. Characterization of Stachybotrys from water-damaged buildings based on morphology, growth, and metabolite production

    DEFF Research Database (Denmark)

    Andersen, Birgitte; Nielsen, Kristian Fog; Jarvis, Bruce

    2002-01-01

    different Stachybotrys taxa, S. chartarum and one undescribed species, were found in water-damaged buildings regardless of whether the buildings were in Denmark, Finland, or the USA. Furthermore, two chemotypes could be distinguished in S. chartarum One chemotype produced atranomes, whereas the other...... was a Macrocyclic trichothecene-producer. The second undescribed taxon produced atranones and could be differentiated from S. chartarum by its growth characteristics arid pigment production. Our results correlate with different inflammatory and toxicological properties reported for these same isolates and show...

  6. Salt Damage and Rising Damp Treatment in Building Structures

    Directory of Open Access Journals (Sweden)

    J. M. P. Q. Delgado

    2016-01-01

    Full Text Available Salt damage can affect the service life of numerous building structures, both historical and contemporary, in a significant way. In this review, various damage mechanisms to porous building materials induced by salt action are analyzed. The importance of pretreatment investigations is discussed as well; in combination with the knowledge of salt and moisture transport mechanisms they can give useful indications regarding treatment options. The methods of salt damage treatment are assessed then, including both passive techniques based on environmental control, reduction of water transport, or conversion to less soluble salts and active procedures resulting in the removal of salts from deterioration zones. It is concluded that cellulose can still be considered as the favorite material presently used in desalination poultices but hydrophilic mineral wool can serve as its prospective alternative in future applications. Another important cause of building pathologies is the rising damp and, in this phenomenon, it is particularly severe considering the presence of salts in water. The treatment of rising damp in historic building walls is a very complex procedure and at Laboratory of Building Physics (LFC-FEUP a wall base hygroregulated ventilation system was developed and patented.

  7. Association of airborne moisture-indicating microorganisms withbuilding-related symptoms and water damage in 100 U.S. office buildings:Analyses of the U.S. EPA BASE data

    Energy Technology Data Exchange (ETDEWEB)

    Mendell, Mark J.; Lei, Quanhong; Cozen, Myrna O.; Shendell, DerekG.; Macher, Janet M.; Tsai, Feng C.

    2003-10-01

    Metrics of culturable airborne microorganisms for either total organisms or suspected harmful subgroups have generally not been associated with symptoms among building occupants. However, the visible presence of moisture damage or mold in residences and other buildings has consistently been associated with respiratory symptoms and other health effects. This relationship is presumably caused by adverse but uncharacterized exposures to moisture-related microbiological growth. In order to assess this hypothesis, we studied relationships in U.S. office buildings between the prevalence of respiratory and irritant symptoms, the concentrations of airborne microorganisms that require moist surfaces on which to grow, and the presence of visible water damage. For these analyses we used data on buildings, indoor environments, and occupants collected from a representative sample of 100 U.S. office buildings in the U.S. Environmental Protection Agency's Building Assessment Survey and Evaluation (EPA BASE) study. We created 19 alternate metrics, using scales ranging from 3-10 units, that summarized the concentrations of airborne moisture-indicating microorganisms (AMIMOs) as indicators of moisture in buildings. Two were constructed to resemble a metric previously reported to be associated with lung function changes in building occupants; the others were based on another metric from the same group of Finnish researchers, concentration cutpoints from other studies, and professional judgment. We assessed three types of associations: between AMIMO metrics and symptoms in office workers, between evidence of water damage and symptoms, and between water damage and AMIMO metrics. We estimated (as odds ratios (ORs) with 95% confidence intervals) the unadjusted and adjusted associations between the 19 metrics and two types of weekly, work-related symptoms--lower respiratory and mucous membrane--using logistic regression models. Analyses used the original AMIMO metrics and were

  8. A new survey tool to assess pluvial damage to residential buildings

    Science.gov (United States)

    Rözer, Viktor; Spekkers, Matthieu; ten Veldhuis, Marie-Claire; Kreibich, Heidi

    2017-04-01

    Pluvial floods have caused severe damage to urban dwellings in Europe and elsewhere in recent years. These type of flood events are caused by storm events with exceptionally high rainfall rates, which lead to inundation of streets and buildings and are commonly associated with a failure of the urban drainage system. Therefore, pluvial floods often happen with little warning and in areas that are not obviously prone to flooding. With a predicted increase in extreme weather events as well as an ongoing urbanization, pluvial flood damage is expected to increase in the future. So far little research was done on the adverse consequences of pluvial floods, as empirical damage data of pluvial flooding is scarce. Therefore, a newly developed survey tool to assess pluvial flood damage as well as the results of a comparison between two international pluvial flood case studies are presented. The questionnaire used in the two study areas was developed with the aim to create a harmonized transnational pluvial flood damage survey that can potentially be extended to other European countries. New indicator variables have been developed to account for different national and regional standards in building structure, early warning, socio-economic data and recovery. The surveys comprise interviews with 510 households in the Münster area (Germany) and 349 households in Amsterdam (the Netherlands), which were affected by the heavy rainfall events on July 28 2014. The respondents were asked more than 80 questions about the damage to their building structure and contents, as well as on topics such as early warning, emergency and precautionary measures, building properties and hazard characteristics. A comparison of the two surveys revealed strong similarities concerning damage reducing effects and the popularity of precautionary measures, besides significant differences between the mean water levels inside the house as well as the median of the building structure and content damage. A

  9. Nonsteroidal Anti-inflammatory Drugs (NSAIDS) Inhibit the Growth and Reproduction of Chaetomium globosum and Other Fungi Associated with Water-Damaged Buildings.

    Science.gov (United States)

    Dalmont, Kelsey; Biles, Charles L; Konsure, Heather; Dahal, Sujita; Rowsey, Tyler; Broge, Matthew; Poudyal, Shubhra; Gurung, Tara; Shrestha, Sabina; Biles, Caleb L; Cluck, Terry; Howard, Alisha

    2017-12-01

    Indoor mold due to water damage causes serious human respiratory disorders, and the remediation to homes, schools, and businesses is a major expense. Prevention of mold infestation of building materials would reduce health problems and building remediation costs. Nonsteroidal anti-inflammatory drugs (NSAIDs) inhibit yeasts and a limited number of filamentous fungi. The purpose of this research was to determine the possible inhibitory activity of nonsteroidal anti-inflammatory drugs (NSAIDs) on germination, fungal growth, and reproduction of Chaetomium globosum and other important filamentous fungi that occur in water-damaged buildings. Several NSAIDs were found to inhibit C. globosum germination, growth, and reproduction. The most effective NSAIDs inhibiting C. globosum were ibuprofen, diflunisal, and diclofenac. Fusarium oxysporum, Fusarium solani, Aspergillus niger, and Stachybotrys atra were also tested on the various media with similar results obtained. However, F. oxysporum and A. niger exhibited a higher level of resistance to aspirin and NaSAL when compared to the C. globosum isolates. The inhibition exhibited by NSAIDs was variable depending on growth media and stage of fungal development. These compounds have a great potential of inhibiting fungal growth on building materials such as gypsum board. Formulations of sprays or building materials with NSAID-like chemical treatments may hold promise in reducing mold in homes and buildings.

  10. Method development of damage detection in asymmetric buildings

    Science.gov (United States)

    Wang, Yi; Thambiratnam, David P.; Chan, Tommy H. T.; Nguyen, Andy

    2018-01-01

    Aesthetics and functionality requirements have caused most buildings to be asymmetric in recent times. Such buildings exhibit complex vibration characteristics under dynamic loads as there is coupling between the lateral and torsional components of vibration, and are referred to as torsionally coupled buildings. These buildings require three dimensional modelling and analysis. In spite of much recent research and some successful applications of vibration based damage detection methods to civil structures in recent years, the applications to asymmetric buildings has been a challenging task for structural engineers. There has been relatively little research on detecting and locating damage specific to torsionally coupled asymmetric buildings. This paper aims to compare the difference in vibration behaviour between symmetric and asymmetric buildings and then use the vibration characteristics for predicting damage in them. The need for developing a special method to detect damage in asymmetric buildings thus becomes evident. Towards this end, this paper modifies the traditional modal strain energy based damage index by decomposing the mode shapes into their lateral and vertical components and to form component specific damage indices. The improved approach is then developed by combining the modified strain energy based damage indices with the modal flexibility method which was modified to suit three dimensional structures to form a new damage indicator. The procedure is illustrated through numerical studies conducted on three dimensional five-story symmetric and asymmetric frame structures with the same layout, after validating the modelling techniques through experimental testing of a laboratory scale asymmetric building model. Vibration parameters obtained from finite element analysis of the intact and damaged building models are then applied into the proposed algorithms for detecting and locating the single and multiple damages in these buildings. The results

  11. Hurricane Harvey Building Damage Assessment Using UAV Data

    Science.gov (United States)

    Yeom, J.; Jung, J.; Chang, A.; Choi, I.

    2017-12-01

    Hurricane Harvey which was extremely destructive major hurricane struck southern Texas, U.S.A on August 25, causing catastrophic flooding and storm damages. We visited Rockport suffered severe building destruction and conducted UAV (Unmanned Aerial Vehicle) surveying for building damage assessment. UAV provides very high resolution images compared with traditional remote sensing data. In addition, prompt and cost-effective damage assessment can be performed regardless of several limitations in other remote sensing platforms such as revisit interval of satellite platforms, complicated flight plan in aerial surveying, and cloud amounts. In this study, UAV flight and GPS surveying were conducted two weeks after hurricane damage to generate an orthomosaic image and a DEM (Digital Elevation Model). 3D region growing scheme has been proposed to quantitatively estimate building damages considering building debris' elevation change and spectral difference. The result showed that the proposed method can be used for high definition building damage assessment in a time- and cost-effective way.

  12. Building Damage Extraction Triggered by Earthquake Using the Uav Imagery

    Science.gov (United States)

    Li, S.; Tang, H.

    2018-04-01

    When extracting building damage information, we can only determine whether the building is collapsed using the post-earthquake satellite images. Even the satellite images have the sub-meter resolution, the identification of slightly damaged buildings is still a challenge. As the complementary data to satellite images, the UAV images have unique advantages, such as stronger flexibility and higher resolution. In this paper, according to the spectral feature of UAV images and the morphological feature of the reconstructed point clouds, the building damage was classified into four levels: basically intact buildings, slightly damaged buildings, partially collapsed buildings and totally collapsed buildings, and give the rules of damage grades. In particular, the slightly damaged buildings are determined using the detected roof-holes. In order to verify the approach, we conduct experimental simulations in the cases of Wenchuan and Ya'an earthquakes. By analyzing the post-earthquake UAV images of the two earthquakes, the building damage was classified into four levels, and the quantitative statistics of the damaged buildings is given in the experiments.

  13. Development of damage functions for high-rise building components

    International Nuclear Information System (INIS)

    Kustu, O.; Miller, D.D.; Brokken, S.T.

    1982-10-01

    The component approach for predicting the effects that ground motion from underground nuclear explosions will have on structures involves predicting the damage to each structural and nonstructural component of a building on the basis of the expected local deformation that most affects the damage to the component. This study was conducted to provide the basic data necessary to evaluate the component approach. Available published laboratory test data for various high-rise building components were collected. These data were analyzed statistically to determine damage threshold values and their variabilities, which in turn were used to derive component damage functions. The portion of construction costs attributable to various building components was determined statistically. This information was needed because component damage functions define damage as a percentage of the replacement values of the component, and, in order to calculate the overall building damage factor, the relative cost of each component must be estimated. The feasibility of the component approach to damage prediction is demonstrated. It is recommended that further experimental research directed towards developing an adequate data base of component damage thresholds for all significant building components should be encouraged. Parallel to this effort, detailed damage data from specific buildings damaged in earthquakes should be collected to verify the theoretical procedure

  14. Coupled analysis of building damage due to tunneling

    NARCIS (Netherlands)

    Giardina, G.; Hendriks, M.A.N.; Rots, J.G.

    2009-01-01

    Excavation works in urban areas require a preliminary risk damage assessment. In historical cities, the prediction of building response to settlements is necessary to reduce the risk of damage of the architectural heritage. The current method used to predict the building damage due to ground

  15. Enhancement of global flood damage assessments using building material based vulnerability curves

    Science.gov (United States)

    Englhardt, Johanna; de Ruiter, Marleen; de Moel, Hans; Aerts, Jeroen

    2017-04-01

    This study discusses the development of an enhanced approach for flood damage and risk assessments using vulnerability curves that are based on building material information. The approach draws upon common practices in earthquake vulnerability assessments, and is an alternative for land-use or building occupancy approach in flood risk assessment models. The approach is of particular importance for studies where there is a large variation in building material, such as large scale studies or studies in developing countries. A case study of Ethiopia is used to demonstrate the impact of the different methodological approaches on direct damage assessments due to flooding. Generally, flood damage assessments use damage curves for different land-use or occupancy types (i.e. urban or residential and commercial classes). However, these categories do not necessarily relate directly to vulnerability of damage by flood waters. For this, the construction type and building material may be more important, as is used in earthquake risk assessments. For this study, we use building material classification data of the PAGER1 project to define new building material based vulnerability classes for flood damage. This approach will be compared to the widely applied land-use based vulnerability curves such as used by De Moel et al. (2011). The case of Ethiopia demonstrates and compares the feasibility of this novel flood vulnerability method on a country level which holds the potential to be scaled up to a global level. The study shows that flood vulnerability based on building material also allows for better differentiation between flood damage in urban and rural settings, opening doors to better link to poverty studies when such exposure data is available. Furthermore, this new approach paves the road to the enhancement of multi-risk assessments as the method enables the comparison of vulnerability across different natural hazard types that also use material-based vulnerability curves

  16. Ice crystallization in porous building materials: assessing damage using real-time 3D monitoring

    Science.gov (United States)

    Deprez, Maxim; De Kock, Tim; De Schutter, Geert; Cnudde, Veerle

    2017-04-01

    Frost action is one of the main causes of deterioration of porous building materials in regions at middle to high latitudes. Damage will occur when the internal stresses due to ice formation become larger than the strength of the material. Hence, the sensitivity of the material to frost damage is partly defined by the structure of the solid body. On the other hand, the size, shape and interconnection of pores manages the water distribution in the building material and, therefore, the characteristics of the pore space control potential to form ice crystals (Ruedrich et al., 2011). In order to assess the damage to building materials by ice crystallization, lot of effort was put into identifying the mechanisms behind the stress build up. First of all, volumetric expansion of 9% (Hirschwald, 1908) during the transition of water to ice should be mentioned. Under natural circumstances, however, water saturation degrees within natural rocks or concrete cannot reach a damaging value. Therefore, linear growth pressure (Scherer, 1999), as well as several mechanisms triggered by water redistribution during freezing (Powers and Helmuth, 1953; Everett, 1961) are more likely responsible for damage due to freezing. Nevertheless, these theories are based on indirect observations and models and, thus, direct evidence that reveals the exact damage mechanism under certain conditions is still lacking. To obtain this proof, in-situ information needs to be acquired while a freezing process is performed. X-ray computed tomography has proven to be of great value in material research. Recent advances at the Ghent University Centre for Tomography (UGCT) have already allowed to dynamically 3D image crack growth in natural rock during freeze-thaw cycles (De Kock et al., 2015). A great potential to evaluate the different stress build-up mechanisms can be found in this imaging technique consequently. It is required to cover a range of materials with different petrophysical properties to achieve

  17. Magnesium-oxide boards cause moisture damage inside facades in new Danish buildings

    DEFF Research Database (Denmark)

    Hansen, Kurt Kielsgaard; Bunch-Nielsen, Tommy; Grelk, Bent

    2016-01-01

    building elements seemed to suffer from some sort of disease, which manifested itself by damages such as significant moisture, boards leaking salty water (‘tears’), corrosion of fittings and anchors and mould growth. The damages were caused by the fact that MgO-boards absorb moisture from outside air...... in periods with high outdoor humidity (90-100% RH) and form water drops on the surfaces. The drops contain a high amount of soluble chloride ions and appear on the surfaces of the boards and may often run down the boards and to adjacent structures. Metal fixtures for the MgO-and siding boards may corrode...

  18. Damage detection in high-rise buildings using damage-induced rotations

    International Nuclear Information System (INIS)

    Sung, Seung Hun; Jung, Ho Youn; Lee, Jung Hoon; Jung, Hyung Jo

    2016-01-01

    In this paper, a new damage-detection method based on structural vibration is proposed. The essence of the proposed method is the detection of abrupt changes in rotation. Damage-induced rotation (DIR), which is determined from the modal flexibility of the structure, initially occurs only at a specific damaged location. Therefore, damage can be localized by evaluating abrupt changes in rotation. We conducted numerical simulations of two damage scenarios using a 10-story cantilever-type building model. Measurement noise was also considered in the simulation. We compared the sensitivity of the proposed method to localize damage to that of two conventional modal-flexibility-based damage-detection methods, i.e., uniform load surface (ULS) and ULS curvature. The proposed method was able to localize damage in both damage scenarios for cantilever structures, but the conventional methods could not

  19. Damage detection in high-rise buildings using damage-induced rotations

    International Nuclear Information System (INIS)

    Sung, Seung Hoon; Jung, Ho Youn; Lee, Jung Hoon; Jung, Hyung Jo

    2014-01-01

    In this paper, a new damage-detection method based on structural vibration is proposed. The essence of the proposed method is the detection of abrupt changes in rotation. Damage-induced rotation (DIR), which is determined from the modal flexibility of the structure, initially occurs only at a specific damaged location. Therefore, damage can be localized by evaluating abrupt changes in rotation. We conducted numerical simulations of two damage scenarios using a 10-story cantilever-type building model. Measurement noise was also considered in the simulation. We compared the sensitivity of the proposed method to localize damage to that of two conventional modal-flexibility-based damage-detection methods, i.e., uniform load surface (ULS) and ULS curvature. The proposed method was able to localize damage in both damage scenarios for cantilever structures, but the conventional methods could not.

  20. BUILDING DAMAGE ASSESSMENT AFTER EARTHQUAKE USING POST-EVENT LiDAR DATA

    Directory of Open Access Journals (Sweden)

    H. Rastiveis

    2015-12-01

    Full Text Available After an earthquake, damage assessment plays an important role in leading rescue team to help people and decrease the number of mortality. Damage map is a map that demonstrates collapsed buildings with their degree of damage. With this map, finding destructive buildings can be quickly possible. In this paper, we propose an algorithm for automatic damage map generation after an earthquake using post-event LiDAR Data and pre-event vector map. The framework of the proposed approach has four main steps. To find the location of all buildings on LiDAR data, in the first step, LiDAR data and vector map are registered by using a few number of ground control points. Then, building layer, selected from vector map, are mapped on the LiDAR data and all pixels which belong to the buildings are extracted. After that, through a powerful classifier all the extracted pixels are classified into three classes of “debris”, “intact building” and “unclassified”. Since textural information make better difference between “debris” and “intact building” classes, different textural features are applied during the classification. After that, damage degree for each candidate building is estimated based on the relation between the numbers of pixels labelled as “debris” class to the whole building area. Calculating the damage degree for each candidate building, finally, building damage map is generated. To evaluate the ability proposed method in generating damage map, a data set from Port-au-Prince, Haiti’s capital after the 2010 Haiti earthquake was used. In this case, after calculating of all buildings in the test area using the proposed method, the results were compared to the damage degree which estimated through visual interpretation of post-event satellite image. Obtained results were proved the reliability of the proposed method in damage map generation using LiDAR data.

  1. Economical evaluation of damaged vacuum insulation panels in buildings

    Science.gov (United States)

    Kim, Y. M.; Lee, H. Y.; Choi, G. S.; Kang, J. S.

    2015-12-01

    In Korea, thermal insulation standard of buildings have been tightened annually to satisfy the passive house standard from the year 2009. The current domestic policies about disseminating green buildings are progressively conducted. All buildings should be the zero energy building in the year 2025, obligatorily. The method is applied to one of the key technologies for high-performance insulation for zero energy building. The vacuum insulation panel is an excellent high performance insulation. But thermal performance of damaged vacuum insulation panels is reduced significantly. In this paper, the thermal performance of damaged vacuum insulation panels was compared and analyzed. The measurement result of thermal performance depends on the core material type. The insulation of building envelope is usually selected by economic feasibility. To evaluate the economic feasibility of VIPs, the operation cost was analyzed by simulation according to the types and damaged ratio of VIPs

  2. Evaluation and considerations about fundamental periods of damaged reinforced concrete buildings

    Directory of Open Access Journals (Sweden)

    R. Ditommaso

    2013-07-01

    Full Text Available The aim of this paper is an empirical estimation of the fundamental period of reinforced concrete buildings and its variation due to structural and non-structural damage. The 2009 L'Aquila earthquake has highlighted the mismatch between experimental data and code provisions value not only for undamaged buildings but also for the damaged ones. The 6 April 2009 L'Aquila earthquake provided the first opportunity in Italy to estimate the fundamental period of reinforced concrete (RC buildings after a strong seismic sequence. A total of 68 buildings with different characteristics, such as age, height and damage level, have been investigated by performing ambient vibration measurements that provided their fundamental translational period. Four different damage levels were considered according with the definitions by EMS 98 (European Macroseismic Scale, trying to regroup the estimated fundamental periods versus building heights according to damage. The fundamental period of RC buildings estimated for low damage level is equal to the previous relationship obtained in Italy and Europe for undamaged buildings, well below code provisions. When damage levels are higher, the fundamental periods increase, but again with values much lower than those provided by codes. Finally, the authors suggest a possible update of the code formula for the simplified estimation of the fundamental period of vibration for existing RC buildings, taking into account also the inelastic behaviour.

  3. Damage estimation of subterranean building constructions due to groundwater inundation – the GIS-based model approach GRUWAD

    Directory of Open Access Journals (Sweden)

    R. Schinke

    2012-09-01

    Full Text Available The analysis and management of flood risk commonly focuses on surface water floods, because these types are often associated with high economic losses due to damage to buildings and settlements. The rising groundwater as a secondary effect of these floods induces additional damage, particularly in the basements of buildings. Mostly, these losses remain underestimated, because they are difficult to assess, especially for the entire building stock of flood-prone urban areas. For this purpose an appropriate methodology has been developed and lead to a groundwater damage simulation model named GRUWAD. The overall methodology combines various engineering and geoinformatic methods to calculate major damage processes by high groundwater levels. It considers a classification of buildings by building types, synthetic depth-damage functions for groundwater inundation as well as the results of a groundwater-flow model. The modular structure of this procedure can be adapted in the level of detail. Hence, the model allows damage calculations from the local to the regional scale. Among others it can be used to prepare risk maps, for ex-ante analysis of future risks, and to simulate the effects of mitigation measures. Therefore, the model is a multifarious tool for determining urban resilience with respect to high groundwater levels.

  4. Probabilistic Assessment of Structural Seismic Damage for Buildings in Mid-America

    International Nuclear Information System (INIS)

    Bai, Jong-Wha; Hueste, Mary Beth D.; Gardoni, Paolo

    2008-01-01

    This paper provides an approach to conduct a probabilistic assessment of structural damage due to seismic events with an application to typical building structures in Mid-America. The developed methodology includes modified damage state classifications based on the ATC-13 and ATC-38 damage states and the ATC-38 database of building damage. Damage factors are assigned to each damage state to quantify structural damage as a percentage of structural replacement cost. To account for the inherent uncertainties, these factors are expressed as random variables with a Beta distribution. A set of fragility curves, quantifying the structural vulnerability of a building, is mapped onto the developed methodology to determine the expected structural damage. The total structural damage factor for a given seismic intensity is then calculated using a probabilistic approach. Prediction and confidence bands are also constructed to account for the prevailing uncertainties. The expected seismic structural damage is assessed for a typical building structure in the Mid-America region using the developed methodology. The developed methodology provides a transparent procedure, where the structural damage factors can be updated as additional seismic damage data becomes available

  5. Extent of moisture and mould damage in structures of public buildings

    Directory of Open Access Journals (Sweden)

    Petri J. Annila

    2017-06-01

    Full Text Available The study concentrated on the extent of moisture and mould damage in different structures in 25 public buildings in Finland. Users of all the buildings had health symptoms suspected to be the result of moisture and mould damage, which is why moisture performance assessments had been performed. The assessment reports on each building were available as research material. The reports indicated that the examined buildings suffered from multiple moisture and mould problems in several different structures. On average, however, a relatively small proportion of the total number of structures had suffered damage. On the basis of the research material, damage was most extensive in walls in soil contact (16.3% and base floor structures (12.5%. The lowest damage rates were found in partition walls (2.4%, external walls (2.6% and intermediate floors (2.5%. The results of the study underline the importance of thorough moisture performance assessments to ensure that all point-sized moisture and mould damage is detected.

  6. Lessons learned from the 2016 Kumamoto earthquake: Building damages and behavior of seismically isolated buildings

    Science.gov (United States)

    Morita, Keiko; Takayama, Mineo

    2017-10-01

    Powerful earthquakes stuck Kumamoto and Oita Prefectures in Kyushu, Japan. It began with the Magnitude 6.5 foreshock at 21:26 JST 14 April, followed by the Magnitude 7.3 mainshock at 1:25 JST 16 April, 2016. The sequence earthquakes also involved more than 1700 perceptible earthquakes as of 13 June. The entire sequence was named the 2016 Kumamoto earthquake by the Japan Meteorological Agency. Thousands of buildings and many roads were damaged, and landslides occurred. The Japanese building standard law is revised in 1981. Structural damages were concentrated on buildings constructed prior to 1981. The area of Mashiki and Southern Aso were most badly affected, especially wooden houses extremely damaged. In Japan, Prof. Hideyuki Tada (title at the time) undertook research on laminated rubber bearings in 1978, and put it into practical use in 1981. The single family house at Yachiyodai, Chiba Prefecture is completed in 1983, it's the first seismically isolated building which is installed laminated rubber bearings in Japan. Afterward, this system is gradually adopted to mainly office buildings, like a research laboratory, a hospital, a computer center and other offices. In the 1994 Northridge earthquake, the 1995 Kobe earthquake and 2011 Tohoku earthquake, seismically isolated buildings improve these good performances, and recently number of the buildings have increased, mainly high risk area of earthquakes. Many people believed that Kumamoto was a low risk area. But there were 24 seismically isolated buildings in Kumamoto Prefecture at the time. The seismically isolated buildings indicated excellent performances during the earthquakes. They protected people, buildings and other important facilities from damages caused by the earthquake. The purpose of this paper is to discuss lessons learned from the 2016 Kumamoto earthquake and behavior of seismically isolated buildings in the earthquake.

  7. Mobile augmented reality in support of building damage and safety assessment

    Science.gov (United States)

    Kim, W.; Kerle, N.; Gerke, M.

    2016-02-01

    Rapid and accurate assessment of the state of buildings in the aftermath of a disaster event is critical for an effective and timely response. For rapid damage assessment of buildings, the utility of remote sensing (RS) technology has been widely researched, with focus on a range of platforms and sensors. However, RS-based approaches still have limitations to assess structural integrity and the specific damage status of individual buildings. Structural integrity refers to the ability of a building to hold the entire structure. Consequently, ground-based assessment conducted by structural engineers and first responders is still required. This paper demonstrates the concept of mobile augmented reality (mAR) to improve performance of building damage and safety assessment in situ. Mobile AR provides a means to superimpose various types of reference or pre-disaster information (virtual data) on actual post-disaster building data (real buildings). To adopt mobile AR, this study defines a conceptual framework based on the level of complexity (LOC). The framework consists of four LOCs, and for each of these, the data types, required processing steps, AR implementation and use for damage assessment are described. Based on this conceptualization we demonstrate prototypes of mAR for both indoor and outdoor purposes. Finally, we conduct a user evaluation of the prototypes to validate the mAR approach for building damage and safety assessment.

  8. Bore pile foundation tall buildings closed in the heritage building

    Science.gov (United States)

    Triastuti, Nusa Setiani

    2017-11-01

    Bore pile foundation for high building surroundings heritage building should be not damage. Construction proses must good, no necking, no mixed deep water, no sliding soil, nonporous concrete. Objective the execution of bore pile so that heritage buildings and neighboring buildings that are old do not experience cracks, damage and tilting. The survey methodology was observe the process of the implementation of the dominant silt, clay soil, in addition a limited space and to analyze the results of loading tests, investigations of soil and daily reports. Construction process determines the success of the structure bore pile in high building structure bearing, without damaging a heritage building. Attainment the hard soil depth, density concrete, observable clean reinforcement in the implementation. Monitoring the implementation of, among others, the face of the ground water little reduce in the area and outside the footprint of the building, no impact of vibration drilling equipment, watching the mud content on the water coming out at the time of drilling, concrete volume was monitored each 2 m bore depth of pile, The result researched heritage building was not damage. The test results bore pile axial, lateral analyzed the results have the appropriate force design required.

  9. An investigation on damaged buildings in Ranau due the 2015 Sabah earthquake

    Science.gov (United States)

    Lim, Yang Soh; Tan, Jun Pin; Chiew, Lerk Qing; Chang, Wai Hoe; Lau, Tze Liang

    2017-10-01

    A magnitude 5.9 earthquake struck near Ranau district in Sabah, Malaysia on June 5, 2015. The epicenter was located 14 km from Ranau. Various buildings were damaged by the earthquake. This paper discusses the extent of the destruction to two severely damaged structures in Ranau. An assessment of damaged buildings in Ranau Hospital using microtremor data was conducted after the earthquake event. The building consists of two identical blocks with similar soft-story structural forms. Two microtremor observations were carried out before and after the repair work. The predominant frequencies of the damaged buildings were determined by using the Nakamura's H/V method. Based on the assumption that both identical blocks of building in Ranau Hospital have similar predominant frequencies due to the same structural design and construction quality, results show that B block of Ranau Hospital suffered more damage compared with another block of the building. The predominant frequency of B block is 10% lower than that of A Block. Results obtained are consistent with the observed building performance during the site reconnaissance. The predominant frequency of both buildings measured after the repair work shows 11% to 21% increment, which implies that the lateral stiffness of both buildings has been improved.

  10. Amoebae and other protozoa in material samples from moisture-damaged buildings

    International Nuclear Information System (INIS)

    Yli-Pirilae, T.; Kusnetsov, Jaana; Haatainen, Susanna; Haenninen, Marja; Jalava, Pasi; Reiman, Marjut; Seuri, Markku; Hirvonen, Maija-Riitta; Nevalainen, Aino

    2004-01-01

    Mold growth in buildings has been shown to be associated with adverse health effects. The fungal and bacterial growth on moistened building materials has been studied, but little attention has been paid to the other organisms spawning in the damaged materials. We examined moist building materials for protozoa, concentrating on amoebae. Material samples (n=124) from moisture-damaged buildings were analyzed for amoebae, fungi, and bacteria. Amoebae were detected in 22% of the samples, and they were found to favor cooccurrence with bacteria and the fungi Acremonium spp., Aspergillus versicolor, Chaetomium spp., and Trichoderma spp. In addition, 11 seriously damaged samples were screened for other protozoa. Ciliates and flagellates were found in almost every sample analyzed. Amoebae are known to host pathogenic bacteria, such as chlamydiae, legionellae, and mycobacteria and they may have a role in the complex of exposure that contributes to the health effects associated with moisture damage in buildings

  11. Chaetomium and Stachybotrys in water-damaged buildings

    DEFF Research Database (Denmark)

    Andersen, Birgitte; Lewinska, Anna Malgorzata; Nielsen, Jakob Blæsbjerg

    Fungal growth occurs when parts of the building envelope get very wet due to unfortunate combinations of factors, e.g. thermal bridges/lack of ventilation, shoddy foundations/flooding or leaks in build-in pipes. Chaetomium and Stachybotrys are not as abundant as Penicillium and Aspergillus (Table 1...

  12. Assessment of Seismic Damage on The Exist Buildings Using Fuzzy Logic

    Science.gov (United States)

    Pınar, USTA; Nihat, MOROVA; EVCİ, Ahmet; ERGÜN, Serap

    2018-01-01

    Earthquake as a natural disaster could damage the lives of many people and buildings all over the world. These is micvulnerability of the buildings needs to be evaluated. Accurate evaluation of damage sustained by buildings during natural disaster events is critical to determine the buildings safety and their suitability for future occupancy. The earthquake is one of the disasters that structures face the most. There fore, there is a need to evaluate seismic damage and vulnerability of the buildings to protect them. These days fuzzy systems have been widely used in different fields of science because of its simpli city and efficiency. Fuzzy logic provides a suitable framework for reasoning, deduction, and decision making in fuzzy conditions. In this paper, studies on earthquake hazard evaluation of buildings by fuzzy logic modeling concepts in the literature have been investigated and evaluated, as a whole.

  13. FRF-based structural damage detection of controlled buildings with podium structures: Experimental investigation

    Science.gov (United States)

    Xu, Y. L.; Huang, Q.; Zhan, S.; Su, Z. Q.; Liu, H. J.

    2014-06-01

    How to use control devices to enhance system identification and damage detection in relation to a structure that requires both vibration control and structural health monitoring is an interesting yet practical topic. In this study, the possibility of using the added stiffness provided by control devices and frequency response functions (FRFs) to detect damage in a building complex was explored experimentally. Scale models of a 12-storey main building and a 3-storey podium structure were built to represent a building complex. Given that the connection between the main building and the podium structure is most susceptible to damage, damage to the building complex was experimentally simulated by changing the connection stiffness. To simulate the added stiffness provided by a semi-active friction damper, a steel circular ring was designed and used to add the related stiffness to the building complex. By varying the connection stiffness using an eccentric wheel excitation system and by adding or not adding the circular ring, eight cases were investigated and eight sets of FRFs were measured. The experimental results were used to detect damage (changes in connection stiffness) using a recently proposed FRF-based damage detection method. The experimental results showed that the FRF-based damage detection method could satisfactorily locate and quantify damage.

  14. Molecular profiling of fungal communities in moisture damaged buildings before and after remediation - a comparison of culture-dependent and culture-independent methods

    Directory of Open Access Journals (Sweden)

    Auvinen Petri

    2011-10-01

    Full Text Available Abstract Background Indoor microbial contamination due to excess moisture is an important contributor to human illness in both residential and occupational settings. However, the census of microorganisms in the indoor environment is limited by the use of selective, culture-based detection techniques. By using clone library sequencing of full-length internal transcribed spacer region combined with quantitative polymerase chain reaction (qPCR for 69 fungal species or assay groups and cultivation, we have been able to generate a more comprehensive description of the total indoor mycoflora. Using this suite of methods, we assessed the impact of moisture damage on the fungal community composition of settled dust and building material samples (n = 8 and 16, correspondingly. Water-damaged buildings (n = 2 were examined pre- and post- remediation, and compared with undamaged reference buildings (n = 2. Results Culture-dependent and independent methods were consistent in the dominant fungal taxa in dust, but sequencing revealed a five to ten times higher diversity at the genus level than culture or qPCR. Previously unknown, verified fungal phylotypes were detected in dust, accounting for 12% of all diversity. Fungal diversity, especially within classes Dothideomycetes and Agaricomycetes tended to be higher in the water damaged buildings. Fungal phylotypes detected in building materials were present in dust samples, but their proportion of total fungi was similar for damaged and reference buildings. The quantitative correlation between clone library phylotype frequencies and qPCR counts was moderate (r = 0.59, p Conclusions We examined a small number of target buildings and found indications of elevated fungal diversity associated with water damage. Some of the fungi in dust were attributable to building growth, but more information on the material-associated communities is needed in order to understand the dynamics of microbial communities between

  15. Modelling of settlement induced building damage

    NARCIS (Netherlands)

    Giardina, G.

    2013-01-01

    This thesis focuses on the modelling of settlement induced damage to masonry buildings. In densely populated areas, the need for new space is nowadays producing a rapid increment of underground excavations. Due to the construction of new metro lines, tunnelling activity in urban areas is growing.

  16. ANALYSIS OF FACTORS CAUSING WATER DAMAGE TO LOESS DOUBLE-ARCHED TUNNEL BASED ON TFN-AHP

    Directory of Open Access Journals (Sweden)

    Mao Zheng-jun

    2017-04-01

    Full Text Available In order to analysis the factors causing water damage to loess double-arched tunnel, this paper conducts field investigation on water damage to tunnels on Lishi-Jundu Expressway in Shanxi, China, confirms its development characteristics, builds an index system (covering 36 evaluation indexes for construction condition, design stage, construction stage, and operation stage for the factors causing water damage to loess double-arched tunnel, applies TFN-AHP (triangular fuzzy number-analytic hierarchy process in calculating the weight of indexes at different levels, and obtains the final sequence of weight of the factors causing water seepage to loess double-arched tunnel. It is found out that water damage to loess double-arched tunnel always develops in construction joints, expansion joints, settlement joints, and lining joints of tunnel and even around them; there is dotted water seepage, linear water seepage, and planar water seepage according to the trace and scope of water damage to tunnel lining. The result shows that water damage to loess double-arched tunnel mainly refers to linear water seepage, planar water seepage is also developed well, and partition and equipment box at the entrance and exit of tunnel are prone to water seepage; construction stage is crucial for controlling water damage to loess double-arched tunnel, atmospheric precipitation is the main water source, and the structure defect of double-arched tunnel increases the possibility of water seepage; the final sequence for weight of various factors is similar to the actual result.

  17. Nonstructural damages of reinforced concrete buildings due to 2015 Ranau earthquake

    Science.gov (United States)

    Adiyanto, Mohd Irwan; Majid, Taksiah A.; Nazri, Fadzli Mohamed

    2017-07-01

    On 15th June 2016 a moderate earthquake with magnitude Mw5.9 was occurred in Sabah, Malaysia. Specifically, the epicentre was located at 16 km northwest of Ranau. Less than two days after the first event, a reconnaissance mission took action to investigate the damages on buildings. Since the reinforced concrete buildings in Ranau were designed based on gravity and wind load only, a lot of minor to severe damages was occurred. This paper presents the damages on the nonstructural elements of reinforced concrete buildings due to Ranau earthquake. The assessment was conducted via in-situ field investigation covering the visual observation, taking photo, and interview with local resident. Based on in-situ field investigation, there was a lot of damages occurred on the nonstructural elements like the brick walls. Such damages cannot be neglected since it can cause injury and fatality to the victims. Therefore, it can be concluded that the installation of nonstructural elements should be reviewed for the sake of safety.

  18. Assessment of extent and degree of thermal damage to polymeric materials in the Three Mile Island Unit 2 reactor building

    International Nuclear Information System (INIS)

    Alvares, N.J.

    1986-01-01

    This paper describes assumptions and procedures used to perform thermal damage analysis caused by post loss-of-coolant-accident (LOCA) hydrogen deflagration at Three Mile Island Unit 2 Reactor. Examination of available photographic evidence yields data on the extent and range of thermal and burn damage. Thermal damage to susceptible material in accessible regions of the reactor building was distributed in non-uniform patterns. No clear explanation for non-uniformity was found in examined evidence, e.g., burned materials were adjacent to materials that appear similar but were not burned. Because these items were in proximity to vertical openings that extend the height of the reactor building, the authors assume the unburned materials preferentially absorbed water vapor during periods of high, local steam concentration. A control pendant from the polar crane located in the top of the reactor building sustained asymmetric burn damage of decreasing degree from top to bottom. Evidence suggests the polar-crane pendant side that experienced heaviest damage was exposed to intense radiant energy from a transient fire plume in the reactor containment volume. Simple hydrogen-fire-exposure tests and heat transfer calculations approximate the degree of damage found on inspected materials from the containment building and support for an estimated 8% pre-fire hydrogen

  19. Assessment of extent and degree of thermal damage to polymeric materials in the Three Mile Island Unit 2 Reactor building

    International Nuclear Information System (INIS)

    Alvares, N.J.

    1985-06-01

    This paper describes assumptions and procedures used to perform thermal damage analysis caused by post loss-of-coolant-accident (LOCA) hydrogen deflagration at Three Mile Island Unit 2 Reactor. Examination of available photographic evidence yields data on the extent and range of thermal and burn damage. Thermal damage to susceptible material in accessible regions of the reactor building was distributed in non-uniform patterns. No clear explanation for non-uniformity was found in examined evidence, e.g., burned materials were adjacent to materials that appear similar but were not burned. Because these items were in proximity to vertical openings that extend the height of the reactor building, we assume the unburned materials preferentially absorbed water vapor during periods of high, local steam concentration. A control pendant from the polar crane located in the top of the reactor building sustained asymmetric burn damage of decreasing degree from top to bottom. Evidence suggests the polar-crane pendant side that experienced heaviest damage was exposed to intense radiant energy from a transient fire plume in the reactor containment volume. Simple hydrogen-fire-exposure tests and heat transfer calculations approximate the degree of damage found on inspected materials from the containment building and support for an estimated 8% pre-fire hydrogen

  20. Assessment of thermal damage to polymeric materials by hydrogen deflagration in the Three Mile Island Unit 2 Reactor Building

    International Nuclear Information System (INIS)

    Alvares, N.J.

    1985-05-01

    Thermal damage to susceptible material in accessible regions of the reactor building was distributed in non-uniform patterns. No clear explanation for non-uniformity was found in examined evidence, e.g., burned materials were adjacent to materials that appear similar but were not burned. Because these items were in proximity to vertical openings that extend the height of the reactor building, we assume the unburned materials preferentially absorbed water vapor during periods of high, local steam concentration. Simple hydrogen-fire-exposure tests and heat transfer calculations duplicate the degree of damage found on inspected materials from the containment building. These data support estimated 8% pre-fire hydrogen concentration predictions based on various hydrogen production mechanisms

  1. Analysis of a school building damaged by the 2015 Ranau earthquake Malaysia

    Science.gov (United States)

    Takano, Shugo; Saito, Taiki

    2017-10-01

    On June 5th, 2015 a severe earthquake with a moment Magnitude of 6.0 occurred in Ranau, Malaysia. Depth of the epicenter is 10 km. Due to the earthquake, many facilities were damaged and 18 people were killed due to rockfalls [1]. Because the British Standard (BS) is adopted as a regulation for built buildings in Malaysia, the seismic force is not considered in the structural design. Therefore, the seismic resistance of Malaysian buildings is unclear. To secure the human life and building safety, it is important to grasp seismic resistance of the building. The objective of this study is to evaluate the seismic resistance of the existing buildings in Malaysia built by the British Standard. A school building that was damaged at the Ranau earthquake is selected as the target building. The building is a four story building and the ground floor is designed to be a parking space for the staff. The structural types are infill masonries where main frame is configured by reinforced concrete columns and beams and brick is installed inside the frame as walls. Analysis is performed using the STERA_3D software that is the software to analyze the seismic performance of buildings developed by one of the authors. Firstly, the natural period of the building is calculated and compared with the result of micro-tremor measurement. Secondly, the nonlinear push-over analysis was conducted to evaluate the horizontal load bearing capacity of the building. Thirdly, the earthquake response analysis was conducted using the time history acceleration data measured at the Ranau earthquake by the seismograph installed at Kota Kinabalu. By comparing the results of earthquake response analysis and the actual damage of the building, the reason that caused damage to the building is clarified.

  2. Research on Optimal Observation Scale for Damaged Buildings after Earthquake Based on Optimal Feature Space

    Science.gov (United States)

    Chen, J.; Chen, W.; Dou, A.; Li, W.; Sun, Y.

    2018-04-01

    A new information extraction method of damaged buildings rooted in optimal feature space is put forward on the basis of the traditional object-oriented method. In this new method, ESP (estimate of scale parameter) tool is used to optimize the segmentation of image. Then the distance matrix and minimum separation distance of all kinds of surface features are calculated through sample selection to find the optimal feature space, which is finally applied to extract the image of damaged buildings after earthquake. The overall extraction accuracy reaches 83.1 %, the kappa coefficient 0.813. The new information extraction method greatly improves the extraction accuracy and efficiency, compared with the traditional object-oriented method, and owns a good promotional value in the information extraction of damaged buildings. In addition, the new method can be used for the information extraction of different-resolution images of damaged buildings after earthquake, then to seek the optimal observation scale of damaged buildings through accuracy evaluation. It is supposed that the optimal observation scale of damaged buildings is between 1 m and 1.2 m, which provides a reference for future information extraction of damaged buildings.

  3. High Resolution SAR Imaging Employing Geometric Features for Extracting Seismic Damage of Buildings

    Science.gov (United States)

    Cui, L. P.; Wang, X. P.; Dou, A. X.; Ding, X.

    2018-04-01

    Synthetic Aperture Radar (SAR) image is relatively easy to acquire but difficult for interpretation. This paper probes how to identify seismic damage of building using geometric features of SAR. The SAR imaging geometric features of buildings, such as the high intensity layover, bright line induced by double bounce backscattering and dark shadow is analysed, and show obvious differences texture features of homogeneity, similarity and entropy in combinatorial imaging geometric regions between the un-collapsed and collapsed buildings in airborne SAR images acquired in Yushu city damaged by 2010 Ms7.1 Yushu, Qinghai, China earthquake, which implicates a potential capability to discriminate collapsed and un-collapsed buildings from SAR image. Study also shows that the proportion of highlight (layover & bright line) area (HA) is related to the seismic damage degree, thus a SAR image damage index (SARDI), which related to the ratio of HA to the building occupation are of building in a street block (SA), is proposed. While HA is identified through feature extraction with high-pass and low-pass filtering of SAR image in frequency domain. A partial region with 58 natural street blocks in the Yushu City are selected as study area. Then according to the above method, HA is extracted, SARDI is then calculated and further classified into 3 classes. The results show effective through validation check with seismic damage classes interpreted artificially from post-earthquake airborne high resolution optical image, which shows total classification accuracy 89.3 %, Kappa coefficient 0.79 and identical to the practical seismic damage distribution. The results are also compared and discussed with the building damage identified from SAR image available by other authors.

  4. Story damage index of seismically-excited buildings based on modal parameters

    International Nuclear Information System (INIS)

    Wang J.-F.; Lin, C.-C.; Yen, S.-M.

    2005-01-01

    In this paper, a story damage index (SDI) for buildings is developed and expressed as a simple formula based on modal parameters extracted from real earthquake response records. It is useful because only one set of modal parameters is required for the calculation of the SDI to show the degree of damage of the story in question. According to numerical simulation results of five-story buildings with various story stiffness reductions and floor mass distributions, it is proven that the proposed SDI has both high accuracy and high reliability. This SDI is also applied to the damage assessment of a 7-story reinforced concrete hotel building in Van Nuys, California, which experienced severe structural damage during the 1994 Northridge earthquake. With both its fundamental frequency and mode shape identified by the SRIM (System Realization using Information Matrix) identification technique, it is shown that the SDI agrees fairly well with the results of the visual inspection, and is valuable in practical application. (authors)

  5. Molecular profiling of fungal communities in moisture damaged buildings before and after remediation--a comparison of culture-dependent and culture-independent methods.

    Science.gov (United States)

    Pitkäranta, Miia; Meklin, Teija; Hyvärinen, Anne; Nevalainen, Aino; Paulin, Lars; Auvinen, Petri; Lignell, Ulla; Rintala, Helena

    2011-10-21

    Indoor microbial contamination due to excess moisture is an important contributor to human illness in both residential and occupational settings. However, the census of microorganisms in the indoor environment is limited by the use of selective, culture-based detection techniques. By using clone library sequencing of full-length internal transcribed spacer region combined with quantitative polymerase chain reaction (qPCR) for 69 fungal species or assay groups and cultivation, we have been able to generate a more comprehensive description of the total indoor mycoflora. Using this suite of methods, we assessed the impact of moisture damage on the fungal community composition of settled dust and building material samples (n = 8 and 16, correspondingly). Water-damaged buildings (n = 2) were examined pre- and post- remediation, and compared with undamaged reference buildings (n = 2). Culture-dependent and independent methods were consistent in the dominant fungal taxa in dust, but sequencing revealed a five to ten times higher diversity at the genus level than culture or qPCR. Previously unknown, verified fungal phylotypes were detected in dust, accounting for 12% of all diversity. Fungal diversity, especially within classes Dothideomycetes and Agaricomycetes tended to be higher in the water damaged buildings. Fungal phylotypes detected in building materials were present in dust samples, but their proportion of total fungi was similar for damaged and reference buildings. The quantitative correlation between clone library phylotype frequencies and qPCR counts was moderate (r = 0.59, p environments. However, making conclusions concerning the effect of building conditions on building mycobiota using this methodology was complicated by the wide natural diversity in the dust samples, the incomplete knowledge of material-associated fungi fungi and the semiquantitative nature of sequencing based methods.

  6. Seismic damage assessment for high-rise buildings

    Science.gov (United States)

    Scholl, Roger E.

    1980-01-01

    The problem considered in this project, conducted by URS/John A. Blume & Associates, Engineers (URS/Blume), for the U.S. Geological Survey, is the identification, evaluation, and correlation of ground-motion and structural parameters in order to improve procedures for predicting dollar losses for high-rise structures damaged by earthquakes. Ground-motion data bases, analytical techniques, and known motion-damage relationships already developed for high-rise buildings and for other classes of structures will be refined and extended so that reliable quantitative seismic risk evaluations can be made.

  7. Building damage assessment from PolSAR data using texture parameters of statistical model

    Science.gov (United States)

    Li, Linlin; Liu, Xiuguo; Chen, Qihao; Yang, Shuai

    2018-04-01

    Accurate building damage assessment is essential in providing decision support for disaster relief and reconstruction. Polarimetric synthetic aperture radar (PolSAR) has become one of the most effective means of building damage assessment, due to its all-day/all-weather ability and richer backscatter information of targets. However, intact buildings that are not parallel to the SAR flight pass (termed oriented buildings) and collapsed buildings share similar scattering mechanisms, both of which are dominated by volume scattering. This characteristic always leads to misjudgments between assessments of collapsed buildings and oriented buildings from PolSAR data. Because the collapsed buildings and the intact buildings (whether oriented or parallel buildings) have different textures, a novel building damage assessment method is proposed in this study to address this problem by introducing texture parameters of statistical models. First, the logarithms of the estimated texture parameters of different statistical models are taken as a new texture feature to describe the collapse of the buildings. Second, the collapsed buildings and intact buildings are distinguished using an appropriate threshold. Then, the building blocks are classified into three levels based on the building block collapse rate. Moreover, this paper also discusses the capability for performing damage assessment using texture parameters from different statistical models or using different estimators. The RADARSAT-2 and ALOS-1 PolSAR images are used to present and analyze the performance of the proposed method. The results show that using the texture parameters avoids the problem of confusing collapsed and oriented buildings and improves the assessment accuracy. The results assessed by using the K/G0 distribution texture parameters estimated based on the second moment obtain the highest extraction accuracies. For the RADARSAT-2 and ALOS-1 data, the overall accuracy (OA) for these three types of

  8. Bilding (Kay) Ki Damaje PSA (:60) (Damaged Buildings)

    Centers for Disease Control (CDC) Podcasts

    2010-02-18

    An important public health announcement about your safety when entering damaged buildings. Language: Haitian Creole.  Created: 2/18/2010 by Centers for Disease Control and Prevention (CDC).   Date Released: 2/18/2010.

  9. Natural Frequencies Evaluation on Partially Damaged Building using Ambient Vibration Technique

    Science.gov (United States)

    Kamarudin, A. F.; Zainal Abidin, M. H.; Daud, M. E.; Noh, M. S. Md; Madun, A.; Ibrahim, A.; Matarul, J.; Mokhatar, S. N.

    2018-04-01

    Severe damages observed on the school blocks, roads, retaining walls and drainage within the compound of SMK Kundasang Sabah possibly due to the ground movements triggered by the Ranau earthquake in 1991. Ambient vibration measurements were carried on the remaining demolished 3-storey building which partially damaged in order to measure the predominant building frequencies using tri-axial 1 Hz seismometer sensors. Popular methods of Horizontal-to-vertical spectral ratios (HVSR) and Fourier amplitude spectra (FAS) were used to compute the ambient vibration wave fields of each building axes (Transverse or North-South (NS), Longitudinal or East-West (EW) and vertical) into Fourier spectra. Two main modes of translation and torsion were observed from the peaks frequencies obtained at 2.99 to 3.10 Hz (1st mode), 4.85 Hz (2nd mode) and 5.63 to 5.85 Hz (3rd mode). The building experiencing translation modes of bending and shear in the NS and EW directions. It could be seen when the amplitudes tends to increase when the floor are increased. Meanwhile, the torsional bending mode is expected to occur when the deformation amplitudes are found to be increasing horizontally, when moving into partially structural damaged section located on the East wing of building.

  10. Water sustainable management for buildings Water sustainable management for buildings

    Directory of Open Access Journals (Sweden)

    Juan Arturo Ocaña Ponce

    2013-01-01

    Full Text Available This paper presents a literature review article that deals with how to manage water in build­ings, specifically in facility projects, in ways to save water during the use, maintenance and operation of the building. This work is aimed at architects, builders and developers, and may be helpful for decision-making in the planning and management of efficient water use in buildings.Este trabajo es un artículo de revisión relacionado con el manejo y gestión del recurso agua, particularmente en proyectos de edificaciones, con el fin de propiciar ahorro de agua durante el uso, mantenimiento y operación del inmueble. Este documento está dirigido a arquitectos, constructores y desarrolladores inmobiliarios y puede ser de gran utilidad para la toma de decisiones en la fase de planeación y de gestión del uso eficiente del agua en los edificios.

  11. Bilding (Kay) Ki Damaje PSA (:30) (Damaged Buildings)

    Centers for Disease Control (CDC) Podcasts

    2010-02-18

    An important public health announcement about safety precautions for potential physical and chemical hazards found in damaged buildings. Language: Haitian Creole.  Created: 2/18/2010 by Centers for Disease Control and Prevention (CDC).   Date Released: 2/18/2010.

  12. The nuclear accident of Fukushima Daiichi - Management of contaminated waters from damaged reactors. Situation at the end of June 2103

    International Nuclear Information System (INIS)

    2013-01-01

    This report first describes the water accumulation and continuous flow in buildings of the Fukushima nuclear power station. This water has different origins: some was used to cool the damaged reactors, and some comes from the underground. Waters under buildings must to pumped, processed and stored. The report describes the main objectives of water processing (desalinating and partial removal of radionuclides) and how they are addressed by Tepco. The last part briefly describes how and where Tepco is storing this always increasing volume of processed waters, with of course other water-tightness problems

  13. Developing Dynamic Digital Image Correlation Technique to Monitor Structural Damage of Old Buildings under External Excitation

    Directory of Open Access Journals (Sweden)

    Ming-Hsiang Shih

    2014-01-01

    Full Text Available The capacity of buildings to resist external excitation is an important factor to consider for the structural design of buildings. When subject to external excitation, a building may suffer a certain degree of damages, and its residual capacity to resist external excitation cannot be evaluated. In this research, dynamic digital image correlation method combined with parameter evaluation available in system identification is used to evaluate the structural capacity to resist external excitation. The results reveal possible building latent safety problems so that timely structural reinforcement or dismantling of the building can be initiated to alleviate further damages. The results of experiments using the proposed method conform to the results obtained using the conventional method, but this method is more convenient and rapid than the latter in the subsequent procedure of data processing. If only the frequency change is used, the damages suffered by the building can be detected, but the damage location is not revealed. The interstory drift mode shape (IDMS based on the characteristic of story drift has higher sensitivity than the approximate story damage index (ADSI method based on modal frequency and vibration type; however, both indices can be used to determine the degree and location of building damages.

  14. Assessment of the material properties of a fire damaged building

    OpenAIRE

    Oladipupo OLOMO; Olufikayo ADERINLEWO; Moses TANIMOLA; Silvana CROOPE

    2012-01-01

    This study identifies a process for assessing the material properties of a fire damaged building so as to determine whether the remains can be utilized in construction or be demolished. Physical and chemical analysis were carried out on concrete and steel samples taken from various elements of the building after thorough visual inspection of the entire building had been conducted. The physical (non-destructive) tests included the Schmidt hammer and ultrasonic pulse velocity tests on the concr...

  15. The Extraction of Post-Earthquake Building Damage Informatiom Based on Convolutional Neural Network

    Science.gov (United States)

    Chen, M.; Wang, X.; Dou, A.; Wu, X.

    2018-04-01

    The seismic damage information of buildings extracted from remote sensing (RS) imagery is meaningful for supporting relief and effective reduction of losses caused by earthquake. Both traditional pixel-based and object-oriented methods have some shortcoming in extracting information of object. Pixel-based method can't make fully use of contextual information of objects. Object-oriented method faces problem that segmentation of image is not ideal, and the choice of feature space is difficult. In this paper, a new stratage is proposed which combines Convolution Neural Network (CNN) with imagery segmentation to extract building damage information from remote sensing imagery. the key idea of this method includes two steps. First to use CNN to predicate the probability of each pixel and then integrate the probability within each segmentation spot. The method is tested through extracting the collapsed building and uncollapsed building from the aerial image which is acquired in Longtoushan Town after Ms 6.5 Ludian County, Yunnan Province earthquake. The results show that the proposed method indicates its effectiveness in extracting damage information of buildings after earthquake.

  16. Detecting Damaged Building Regions Based on Semantic Scene Change from Multi-Temporal High-Resolution Remote Sensing Images

    Directory of Open Access Journals (Sweden)

    Jihui Tu

    2017-04-01

    Full Text Available The detection of damaged building regions is crucial to emergency response actions and rescue work after a disaster. Change detection methods using multi-temporal remote sensing images are widely used for this purpose. Differing from traditional methods based on change detection for damaged building regions, semantic scene change can provide a new point of view since it can indicate the land-use variation at the semantic level. In this paper, a novel method is proposed for detecting damaged building regions based on semantic scene change in a visual Bag-of-Words model. Pre- and post-disaster scene change in building regions are represented by a uniform visual codebook frequency. The scene change of damaged and non-damaged building regions is discriminated using the Support Vector Machine (SVM classifier. An evaluation of experimental results, for a selected study site of the Longtou hill town of Yunnan, China, which was heavily damaged in the Ludian earthquake of 14 March 2013, shows that this method is feasible and effective for detecting damaged building regions. For the experiments, WorldView-2 optical imagery and aerial imagery is used.

  17. Tornado risk analysis at Savannah River Plant using windspeed damage thresholds and single building strike frequencies

    International Nuclear Information System (INIS)

    Taylor, D.H.; McDonald, J.R.; Twisdale, L.A.

    1985-01-01

    Tornado risk analysis at the Savannah River Plant has taken a two pronged approach: (1) developing a catalogue of damage thresholds as a function of windspeed for processing buildings and other representative site structures; (2) developing a method of estimating, for each building, the probability of a tornado exceeding each damage threshold. Wind resistance of building construction at SRP varies widely depending on the function of the structure. It was recognized that all tornadoes do not necessarily seriously damage buildings, but the damage thresholds were unknown. In order to evaluate the safety of existing structures and properly design new structures, an analysis of tornado resistance was conducted by J.R. McDonald on each process building at SRP and other buildings by type. Damage estimates were catalogued for each Fujita class windspeed interval and windspeeds were catalogued as a function of increased levels of damage. Tornado single point and structure specific strike probabilities for the SRP site were determined by L.A. Twisdale using the TORRISK computer code. To calculate the structure specific strike probability, a correction factor is determined from a set of curves using building area and aspect ratio (length/width relative to north) as parameters. The structure specific probability is then the product of the correction factor and the point probability. The correction factor increases as a function of building size and windspeed. For large buildings (10 5 ft 2 ) and very intense storms (250 mph), the correction factor is equal to or greater than 4. The cumulative probability of a tornado striking any building type (process, personnel, etc.) was also calculated

  18. Damage Level Prediction of Reinforced Concrete Building Based on Earthquake Time History Using Artificial Neural Network

    Directory of Open Access Journals (Sweden)

    Suryanita Reni

    2017-01-01

    Full Text Available The strong motion earthquake could cause the building damage in case of the building not considered in the earthquake design of the building. The study aims to predict the damage-level of building due to earthquake using Artificial Neural Networks method. The building model is a reinforced concrete building with ten floors and height between floors is 3.6 m. The model building received a load of the earthquake based on nine earthquake time history records. Each time history scaled to 0,5g, 0,75g, and 1,0g. The Artificial Neural Networks are designed in 4 architectural models using the MATLAB program. Model 1 used the displacement, velocity, and acceleration as input and Model 2 used the displacement only as the input. Model 3 used the velocity as input, and Model 4 used the acceleration just as input. The output of the Neural Networks is the damage level of the building with the category of Safe (1, Immediate Occupancy (2, Life Safety (3 or in a condition of Collapse Prevention (4. According to the results, Neural Network models have the prediction rate of the damage level between 85%-95%. Therefore, one of the solutions for analyzing the structural responses and the damage level promptly and efficiently when the earthquake occurred is by using Artificial Neural Network

  19. Investigation of hydrogen-burn damage in the Three Mile Island Unit 2 reactor building

    International Nuclear Information System (INIS)

    Alvares, N.J.; Beason, D.G.; Eidem, G.R.

    1982-06-01

    About 10 hours after the March 28, 1979 Loss-of-Coolant Accident began at Three Mile Island Unit 2, a hydrogen deflagration of undetermined extent occurred inside the reactor building. Examinations of photographic evidence, available from the first fifteen entries into the reactor building, yielded preliminary data on the possible extent and range of hydrogen burn damage. These data, although sparse, contributed to development of a possible damage path and to an estimate of the extent of damage to susceptible reactor building items. Further information gathered from analysis of additional photographs and samples can provide the means for estimating hydrogen source and production rate data crucial to developing a complete understanding of the TMI-2 hydrogen deflagration. 34 figures

  20. Building vulnerability to hydro-geomorphic hazards: Estimating damage probability from qualitative vulnerability assessment using logistic regression

    Science.gov (United States)

    Ettinger, Susanne; Mounaud, Loïc; Magill, Christina; Yao-Lafourcade, Anne-Françoise; Thouret, Jean-Claude; Manville, Vern; Negulescu, Caterina; Zuccaro, Giulio; De Gregorio, Daniela; Nardone, Stefano; Uchuchoque, Juan Alexis Luque; Arguedas, Anita; Macedo, Luisa; Manrique Llerena, Nélida

    2016-10-01

    The focus of this study is an analysis of building vulnerability through investigating impacts from the 8 February 2013 flash flood event along the Avenida Venezuela channel in the city of Arequipa, Peru. On this day, 124.5 mm of rain fell within 3 h (monthly mean: 29.3 mm) triggering a flash flood that inundated at least 0.4 km2 of urban settlements along the channel, affecting more than 280 buildings, 23 of a total of 53 bridges (pedestrian, vehicle and railway), and leading to the partial collapse of sections of the main road, paralyzing central parts of the city for more than one week. This study assesses the aspects of building design and site specific environmental characteristics that render a building vulnerable by considering the example of a flash flood event in February 2013. A statistical methodology is developed that enables estimation of damage probability for buildings. The applied method uses observed inundation height as a hazard proxy in areas where more detailed hydrodynamic modeling data is not available. Building design and site-specific environmental conditions determine the physical vulnerability. The mathematical approach considers both physical vulnerability and hazard related parameters and helps to reduce uncertainty in the determination of descriptive parameters, parameter interdependency and respective contributions to damage. This study aims to (1) enable the estimation of damage probability for a certain hazard intensity, and (2) obtain data to visualize variations in damage susceptibility for buildings in flood prone areas. Data collection is based on a post-flood event field survey and the analysis of high (sub-metric) spatial resolution images (Pléiades 2012, 2013). An inventory of 30 city blocks was collated in a GIS database in order to estimate the physical vulnerability of buildings. As many as 1103 buildings were surveyed along the affected drainage and 898 buildings were included in the statistical analysis. Univariate and

  1. A case study on the structural assessment of fire damaged building

    Science.gov (United States)

    Osman, M. H.; Sarbini, N. N.; Ibrahim, I. S.; Ma, C. K.; Ismail, M.; Mohd, M. F.

    2017-11-01

    This paper presents a case study on the structural assessment of building damaged by fire and discussed on the site investigations and test results prior to determine the existing condition of the building. The building was on fire for about one hour before it was extinguished. In order to ascertain the integrity of the building, a visual inspection was conducted for all elements (truss, beam, column and wall), followed by non-destructive, load and material tests. The load test was conducted to determine the ability of truss to resist service load, while the material test to determine the residual strength of the material. At the end of the investigation, a structural analysis was carried out to determine the new factor of safety by considering the residual strength. The highlighted was on the truss element due to steel behaviour that is hardly been predicted. Meanwhile, reinforced concrete elements (beam, column and wall) were found externally affected and caused its strength to be considered as sufficient for further used of building. The new factor of safety is equal to 2, considered as the minimum calculated value for the truss member. Therefore, this fire damaged building was found safe and can be used for further application.

  2. Analysis about factors affecting the degree of damage of buildings in earthquake

    International Nuclear Information System (INIS)

    Jia, Jing; Yan, Jinghong

    2015-01-01

    Earthquakes have been affecting human's safety through human's history. Previous studies on earthquake, mostly, focused on the performance of buildings or evaluating damages. This paper, however, compares different factors that have influence on the damage of buildings with a case study in Wenchuan earthquake, using multiple linear regression methodology, so as to identify to what extend this factors influence the buildings’ damages, then give the rank of importance of these factors. In this process, authors take the type of structure as a dummy variable to compare the degree of damages caused by different types of structure, which were barely studied before. Besides, Factor Analysis Methodology(FA) will be adapted to classify factors, the results of which will simplify later study. The outcome of this study would make a big difference in optimizing the seismic design and improving residential seismic quality. (paper)

  3. Relationship between the spatial distribution of SMS messages reporting needs and building damage in 2010 Haiti disaster

    Directory of Open Access Journals (Sweden)

    C. Corbane

    2012-02-01

    Full Text Available Just 4 days after the M = 7.1 earthquake on 12 January 2010, Haitians could send SMS messages about their location and urgent needs through the on-line mapping platform Ushahidi. This real-time crowdsourcing of crisis information provided direct support to key humanitarian resources on the ground, including Search and Rescue teams. In addition to its use as a knowledge base for rescue operations and aid provision, the spatial distribution of geolocated SMS messages may represent an early indicator on the spatial distribution and on the intensity of building damage.

    This work explores the relationship between the spatial patterns of SMS messages and building damage. The latter is derived from the detailed damage assessment of individual buildings interpreted in post-earthquake airborne photos. The interaction between SMS messages and building damage is studied by analyzing the spatial structure of the corresponding bivariate patterns.

    The analysis is performed through the implementation of cross Ripley's K-function which is suitable for characterizing the spatial structure of a bivariate pattern, and more precisely the spatial relationship between two types of point sets located in the same study area.

    The results show a strong attraction between the patterns exhibited by SMS messages and building damages. The interactions identified between the two patterns suggest that the geolocated SMS can be used as early indicators of the spatial distribution of building damage pattern. Accordingly, a statistical model has been developed to map the distribution of building damage from the geolocated SMS pattern.

    The study presented in this paper is the first attempt to derive quantitative estimates on the spatial patterns of novel crowdsourced information and correlate these to established methods in damage assessment using remote sensing data. The consequences of the study findings for rapid damage detection in

  4. Assessment of Extent and Degree of Thermal Damage to Polymeric Materials in the Three Mile Island Unit 2 Reactor Building

    International Nuclear Information System (INIS)

    Alvares, N. J.

    1984-02-01

    Thermal damage to susceptible materials in accessible regions of the TMI-2 reactor building shows damage-distribution patterns that indicate non-uniform intensity of exposure. No clear explanation for non-uniformity is found in existing evidence; e.g., in some regions a lack of thermally susceptible materials frustrates analysis. Elsewhere, burned materials are present next to materials that seem similar but appear unscathed-leading to conjecture that the latter materials preferentially absorb water vapor during periods of high local steam concentration. Most of the polar crane pendant shows heavy burns on one half of its circumferential surface. This evidence suggests that the polar crane pendant side that experienced heaviest burn damage was exposed to intense radiant energy from a transient fire plume in the reactor containment volume. Tests and simple heat-transfer calculations based on pressure and temperature records from the accident show that the atmosphere inside the reactor building was probably 8% hydrogen in air, a value not inconsistent with the extent of burn damage. Burn-pattern geography indicates uniform thermal exposure in the dome volume to the 406-ft level (about 6 ft below the polar crane girder), partial thermal exposure in the volume between the 406- and 347-ft levels as indicated by the polar crane cable, and lack of damage to most thermally susceptible materials in the west quadrant of the reactor building; some evidence of thermal exposure Is seen in the free volume between the 305- and 347-ft levels. (author)

  5. Earthquake Building Damage Mapping Based on Feature Analyzing Method from Synthetic Aperture Radar Data

    Science.gov (United States)

    An, L.; Zhang, J.; Gong, L.

    2018-04-01

    Playing an important role in gathering information of social infrastructure damage, Synthetic Aperture Radar (SAR) remote sensing is a useful tool for monitoring earthquake disasters. With the wide application of this technique, a standard method, comparing post-seismic to pre-seismic data, become common. However, multi-temporal SAR processes, are not always achievable. To develop a post-seismic data only method for building damage detection, is of great importance. In this paper, the authors are now initiating experimental investigation to establish an object-based feature analysing classification method for building damage recognition.

  6. Estimated probability of the number of buildings damaged by the ...

    African Journals Online (AJOL)

    The analysis shows that the probability estimator of the building damage ... and homeowners) should reserve the cost of repair at least worth the risk of loss, to face ... Keywords: Citarum River; logistic regression; genetic algorithm; losses risk; ...

  7. The influence of water on the strength of Neapolitan Yellow Tuff, the most widely used building stone in Naples (Italy)

    Science.gov (United States)

    Heap, Michael J.; Farquharson, Jamie I.; Kushnir, Alexandra R. L.; Lavallée, Yan; Baud, Patrick; Gilg, H. Albert; Reuschlé, Thierry

    2018-06-01

    Neapolitan Yellow Tuff (NYT) has been used in construction in Naples (Italy) since the Greeks founded the city—then called Neapolis—in the sixth century BCE. We investigate here whether this popular building stone is weaker when saturated with water, an issue important for assessments of weathering damage and monument preservation. To this end, we performed 28 uniaxial compressive strength measurements on dry and water-saturated samples cored from a block of the lithified Upper Member of the NYT. Our experiments show that the strength of the zeolite-rich NYT is systematically reduced when saturated with water (the ratio of wet to dry strength is 0.63). Complementary experiments show that two other common Neapolitan building stones—Piperno Tuff and the grey Campanian Ignimbrite (both facies of the Campanian Ignimbrite deposit devoid of zeolites)—do not weaken when wet. From these data, and previously published data for tuffs around the globe, we conclude that the water-weakening in NYT is a consequence of the presence of abundant zeolites (the block tested herein contains 46 wt.% of zeolites). These data may help explain weathering damage in NYT building stones (due to rainfall, rising damp, and proximity to the sea or water table) and the observed link between rainfall and landslides, rock falls, and sinkhole formation in Naples, and the weathering of other buildings built from zeolite-rich tuffs worldwide.

  8. A time-series study of sick building syndrome: chronic, biotoxin-associated illness from exposure to water-damaged buildings.

    Science.gov (United States)

    Shoemaker, Ritchie C; House, Dennis E

    2005-01-01

    The human health risk for chronic illnesses involving multiple body systems following inhalation exposure to the indoor environments of water-damaged buildings (WDBs) has remained poorly characterized and the subject of intense controversy. The current study assessed the hypothesis that exposure to the indoor environments of WDBs with visible microbial colonization was associated with illness. The study used a cross-sectional design with assessments at five time points, and the interventions of cholestyramine (CSM) therapy, exposure avoidance following therapy, and reexposure to the buildings after illness resolution. The methodological approach included oral administration of questionnaires, medical examinations, laboratory analyses, pulmonary function testing, and measurements of visual function. Of the 21 study volunteers, 19 completed assessment at each of the five time points. Data at Time Point 1 indicated multiple symptoms involving at least four organ systems in all study participants, a restrictive respiratory condition in four participants, and abnormally low visual contrast sensitivity (VCS) in 18 participants. Serum leptin levels were abnormally high and alpha melanocyte stimulating hormone (MSH) levels were abnormally low. Assessments at Time Point 2, following 2 weeks of CSM therapy, indicated a highly significant improvement in health status. Improvement was maintained at Time Point 3, which followed exposure avoidance without therapy. Reexposure to the WDBs resulted in illness reacquisition in all participants within 1 to 7 days. Following another round of CSM therapy, assessments at Time Point 5 indicated a highly significant improvement in health status. The group-mean number of symptoms decreased from 14.9+/-0.8 S.E.M. at Time Point 1 to 1.2+/-0.3 S.E.M., and the VCS deficit of approximately 50% at Time Point 1 was fully resolved. Leptin and MSH levels showed statistically significant improvement. The results indicated that CSM was an effective

  9. Seismic damage diagnosis of a masonry building using short-term damping measurements

    Science.gov (United States)

    Kouris, Leonidas Alexandros S.; Penna, Andrea; Magenes, Guido

    2017-04-01

    It is of considerable importance to perform dynamic identification and detect damage in existing structures. This paper describes a new and practical method for damage diagnosis of masonry buildings requiring minimum computational effort. The method is based on the relative variation of modal damping and validated against experimental data from a full scale two storey shake table test. The experiment involves a building subjected to uniaxial vibrations of progressively increasing intensity at the facilities of EUCENTRE laboratory (Pavia, Italy) up to a near collapse damage state. Five time-histories are applied scaling the Montenegro (1979) accelerogram. These strong motion tests are preceded by random vibration tests (RVT's) which are used to perform modal analysis. Two deterministic methods are applied: the single degree of freedom (SDOF) assumption together with the peak-picking method in the discrete frequency domain and the Eigen realisation algorithm with data correlations (ERA-DC) in the discrete time domain. Regarding the former procedure, some improvements are incorporated to locate rigorously the natural frequencies and estimate the modal damping. The progressive evolution of the modal damping is used as a key indicator to characterise damage on the building. Modal damping is connected to the structural mass and stiffness. A square integrated but only with two components expression for proportional (classical) damping is proposed to fit better with the experimental measurements of modal damping ratios. Using this Rayleigh order formulation the contribution of each of the damping components is evaluated. The stiffness component coefficient is proposed as an effective index to detect damage and quantify its intensity.

  10. The characteristic of the building damage from historical large earthquakes in Kyoto

    Science.gov (United States)

    Nishiyama, Akihito

    2016-04-01

    The Kyoto city, which is located in the northern part of Kyoto basin in Japan, has a long history of >1,200 years since the city was initially constructed. The city has been a populated area with many buildings and the center of the politics, economy and culture in Japan for nearly 1,000 years. Some of these buildings are now subscribed as the world's cultural heritage. The Kyoto city has experienced six damaging large earthquakes during the historical period: i.e., in 976, 1185, 1449, 1596, 1662, and 1830. Among these, the last three earthquakes which caused severe damage in Kyoto occurred during the period in which the urban area had expanded. These earthquakes are considered to be inland earthquakes which occurred around the Kyoto basin. The damage distribution in Kyoto from historical large earthquakes is strongly controlled by ground condition and earthquakes resistance of buildings rather than distance from estimated source fault. Therefore, it is necessary to consider not only the strength of ground shaking but also the condition of building such as elapsed years since the construction or last repair in order to more accurately and reliably estimate seismic intensity distribution from historical earthquakes in Kyoto. The obtained seismic intensity map would be helpful for reducing and mitigating disaster from future large earthquakes.

  11. The evaluation of damage mechanism of unreinforced masonry buildings after Van (2011) and Elazig (2010) Earthquakes

    Science.gov (United States)

    Güney, D.; Aydin, E.; Öztürk, B.

    2015-07-01

    On March 8th, 2010 Karakocan-Elazig earthquake of magnitude 6.0 occurred at a region where masonry and adobe construction is very common. Karakocan-Elazig is located in a high seismicity region on Eastern Anatolian Fault System (EAFS). Due to the earthquake, 42 people were killed and 14’113 buildings were damaged. Another city, Van located at South east of Turkey is hit by earthquakes with M = 7.2 occurred on October 23rd, 2011 at 13:41 (local time), whose epicenter was about 16 km north of Van (Tabanli village) and M = 5.6 on November 9th, 2011 with an epicenter near the town of Edremit, south of Van and caused the loss of life and heavy damages. Both earthquakes killed 644 people and 2608 people were injured. Approximately 10’000 buildings were seriously damaged. There are many traditional types of structures existing in the region hit by earthquakes (both Van and Elazig). These buildings were built as adobe, unreinforced masonry or mixed type. These types of buildings are very common in rural areas (especially south and east) of Turkey because of easy workmanship and cheap construction cost. Many of those traditional type structures experienced serious damages. The use of masonry is very common in some of the world's most hazard-prone regions, such as in Latin America, Africa, the Indian subcontinent and other parts of Asia, the Middle East, and southern Europe. Based on damage and failure mechanism of those buildings, the parameters affecting the seismic performance of those traditional buildings are analyzed in this paper. The foundation type, soil conditions, production method of the masonry blocks, construction method, the geometry of the masonry walls, workmanship quality, existence of wooden beams, type of roof, mortar between adobe blocks are studied in order to understand the reason of damage for these types of buildings.

  12. Evaluation of Water Efficiency in Green Building in Taiwan

    Directory of Open Access Journals (Sweden)

    Cheng-Li Cheng

    2016-06-01

    Full Text Available Low carbon policies, including those aimed at increasing water efficiency, have been adopted as a crucial strategy for combating global warming and climate change. The green building evaluation system used in Taiwan was first applied in 1999 and initially utilized a building’s water efficiency as the threshold index for determining the building’s environmental impact. Since 1999, more than a thousand buildings have been certified as green buildings using this evaluation system. The quantitative effects of water conservation efforts should be provided to policy makers as a form of positive feedback. To that end, the present study offers a calculation process for estimating the quantitative volume of water saved by practical green buildings. The baseline water usage for all kinds of buildings was determined to serve as the criterion for determining the water-saving efficiency of individual buildings. An investigation of the average water-saving rate from 2000 to 2013 for 1320 buildings certified as green buildings was also conducted to validate the estimation results and found that these green buildings saved an average of approximately 37.6% compared to the baseline water usage rate for all buildings. Water savings will inevitably follow from the use of water-saving appliances or water-saving designs for buildings. The proposed calculation process can be used to clarify the relationships between specific water-saving concepts and the real water usage efficiency of green buildings.

  13. Sick building syndrome (SBS) and exposure to water-damaged buildings: time series study, clinical trial and mechanisms.

    Science.gov (United States)

    Shoemaker, Ritchie C; House, Dennis E

    2006-01-01

    Occupants of water-damaged buildings (WDBs) with evidence of microbial amplification often describe a syndrome involving multiple organ systems, commonly referred to as "sick building syndrome" (SBS), following chronic exposure to the indoor air. Studies have demonstrated that the indoor air of WDBs often contains a complex mixture of fungi, mycotoxins, bacteria, endotoxins, antigens, lipopolysaccharides, and biologically produced volatile compounds. A case-series study with medical assessments at five time points was conducted to characterize the syndrome after a double-blinded, placebo-controlled clinical trial conducted among a group of study participants investigated the efficacy of cholestyramine (CSM) therapy. The general hypothesis of the time series study was that chronic exposure to the indoor air of WDBs is associated with SBS. Consecutive clinical patients were screened for diagnosis of SBS using criteria of exposure potential, symptoms involving at least five organ systems, and the absence of confounding factors. Twenty-eight cases signed voluntary consent forms for participation in the time-series study and provided samples of microbial contaminants from water-damaged areas in the buildings they occupied. Twenty-six participants with a group-mean duration of illness of 11 months completed examinations at all five study time points. Thirteen of those participants also agreed to complete a double-blinded, placebo-controlled clinical trial. Data from Time Point 1 indicated a group-mean of 23 out of 37 symptoms evaluated; and visual contrast sensitivity (VCS), an indicator of neurological function, was abnormally low in all participants. Measurements of matrix metalloproteinase 9 (MMP9), leptin, alpha melanocyte stimulating hormone (MSH), vascular endothelial growth factor (VEGF), immunoglobulin E (IgE), and pulmonary function were abnormal in 22, 13, 25, 14, 1, and 7 participants, respectively. Following 2 weeks of CSM therapy to enhance toxin elimination

  14. Drinking Water Quality in Hospitals and Other Buildings ...

    Science.gov (United States)

    Drinking water quality entering large buildings is generally adequately controlled by the water utility, but localized problems may occur within building or “premise” plumbing. Particular concerns are loss of disinfectant residual and temperature variability, which may enhance pathogen activity and metallic corrosion. Disinfection systems are available to building managers and are being installed in a variety of commercial buildings (hospitals, hotels, office buildings.) Yet our understanding of such additional treatment and of how to monitor end water quality at these buildings is limited. This class lecture will discuss challenges in maintaining acceptable water quality in hospitals, schools and other buildings. To give a lecture to a class of graduate students (ENVE 6054: Physical/Chemical Processes for Water Quality Control) at the University of Cincinnati, by presenting past research projects.

  15. On the prediction of building damage from ground motion

    Energy Technology Data Exchange (ETDEWEB)

    Blume, John A [John A. Blume and Associates Research Division, San Francisco, CA (United States)

    1970-05-15

    In the planning of a nuclear event it is essential to consider the effects of the expected ground motion on all exposed buildings and other structures. There are various steps and procedures in this process which generally increase in scope and refinement as the preparations advance. Initial, rough estimates, based upon rules-of-thumb and preliminary predictions of ground motion and structural response, may be adequate to show general feasibility of the project. Subsequent work is done in both the field and analysis phases, to estimate the total structure exposure, to isolate special hazards, and to make damage cost estimates. Finally, specific analyses are made of special buildings or structures to identify safety problems and to make recommendations for safety measures during the proposed event. Because the ground motion and the structural response both involve many random variables and therefore some uncertainties in prediction, the probabilistic aspects must be considered, both on a broad statistical basis and for specific safety considerations. Decisions must be made as to the acceptability or non-acceptability of the risks and any indicated procedures before and during the event to reduce or to eliminate the risks. The paper discusses various techniques involved in these operations including the Spectral Matrix Method of damage prediction, the Threshold Evaluation Scale for specific building analysis, and the inelastic and probabilistic aspects of the problem. (author)

  16. On the prediction of building damage from ground motion

    International Nuclear Information System (INIS)

    Blume, John A.

    1970-01-01

    In the planning of a nuclear event it is essential to consider the effects of the expected ground motion on all exposed buildings and other structures. There are various steps and procedures in this process which generally increase in scope and refinement as the preparations advance. Initial, rough estimates, based upon rules-of-thumb and preliminary predictions of ground motion and structural response, may be adequate to show general feasibility of the project. Subsequent work is done in both the field and analysis phases, to estimate the total structure exposure, to isolate special hazards, and to make damage cost estimates. Finally, specific analyses are made of special buildings or structures to identify safety problems and to make recommendations for safety measures during the proposed event. Because the ground motion and the structural response both involve many random variables and therefore some uncertainties in prediction, the probabilistic aspects must be considered, both on a broad statistical basis and for specific safety considerations. Decisions must be made as to the acceptability or non-acceptability of the risks and any indicated procedures before and during the event to reduce or to eliminate the risks. The paper discusses various techniques involved in these operations including the Spectral Matrix Method of damage prediction, the Threshold Evaluation Scale for specific building analysis, and the inelastic and probabilistic aspects of the problem. (author)

  17. Contribution of insurance data to cost assessment of coastal flood damage to residential buildings: insights gained from Johanna (2008 and Xynthia (2010 storm events

    Directory of Open Access Journals (Sweden)

    C. André

    2013-08-01

    Full Text Available There are a number of methodological issues involved in assessing damage caused by natural hazards. The first is the lack of data, due to the rarity of events and the widely different circumstances in which they occur. Thus, historical data, albeit scarce, should not be neglected when seeking to build ex-ante risk management models. This article analyses the input of insurance data for two recent severe coastal storm events, to examine what causal relationships may exist between hazard characteristics and the level of damage incurred by residential buildings. To do so, data was collected at two levels: from lists of about 4000 damage records, 358 loss adjustment reports were consulted, constituting a detailed damage database. The results show that for flooded residential buildings, over 75% of reconstruction costs are associated with interior elements, with damage to structural components remaining very localised and negligible. Further analysis revealed a high scatter between costs and water depth, suggesting that uncertainty remains high in drawing up damage functions with insurance data alone. Due to the paper format of the loss adjustment reports, and the lack of harmonisation between their contents, the collection stage called for a considerable amount of work. For future events, establishing a standardised process for archiving damage information could significantly contribute to the production of such empirical damage functions. Nevertheless, complementary sources of data on hazards and asset vulnerability parameters will definitely still be necessary for damage modelling; multivariate approaches, crossing insurance data with external material, should also be investigated more deeply.

  18. Contribution of insurance data to cost assessment of coastal flood damage to residential buildings: insights gained from Johanna (2008) and Xynthia (2010) storm events

    Science.gov (United States)

    André, C.; Monfort, D.; Bouzit, M.; Vinchon, C.

    2013-08-01

    There are a number of methodological issues involved in assessing damage caused by natural hazards. The first is the lack of data, due to the rarity of events and the widely different circumstances in which they occur. Thus, historical data, albeit scarce, should not be neglected when seeking to build ex-ante risk management models. This article analyses the input of insurance data for two recent severe coastal storm events, to examine what causal relationships may exist between hazard characteristics and the level of damage incurred by residential buildings. To do so, data was collected at two levels: from lists of about 4000 damage records, 358 loss adjustment reports were consulted, constituting a detailed damage database. The results show that for flooded residential buildings, over 75% of reconstruction costs are associated with interior elements, with damage to structural components remaining very localised and negligible. Further analysis revealed a high scatter between costs and water depth, suggesting that uncertainty remains high in drawing up damage functions with insurance data alone. Due to the paper format of the loss adjustment reports, and the lack of harmonisation between their contents, the collection stage called for a considerable amount of work. For future events, establishing a standardised process for archiving damage information could significantly contribute to the production of such empirical damage functions. Nevertheless, complementary sources of data on hazards and asset vulnerability parameters will definitely still be necessary for damage modelling; multivariate approaches, crossing insurance data with external material, should also be investigated more deeply.

  19. Seismic response and damage detection analyses of an instrumented steel moment-framed building

    Science.gov (United States)

    Rodgers, J.E.; Celebi, M.

    2006-01-01

    The seismic performance of steel moment-framed buildings has been of particular interest since brittle fractures were discovered at the beam-column connections in a number of buildings following the M 6.7 Northridge earthquake of January 17, 1994. A case study of the seismic behavior of an extensively instrumented 13-story steel moment frame building located in the greater Los Angeles area of California is described herein. Response studies using frequency domain, joint time-frequency, system identification, and simple damage detection analyses are performed using an extensive strong motion dataset dating from 1971 to the present, supported by engineering drawings and results of postearthquake inspections. These studies show that the building's response is more complex than would be expected from its highly symmetrical geometry. The response is characterized by low damping in the fundamental mode, larger accelerations in the middle and lower stories than at the roof and base, extended periods of vibration after the cessation of strong input shaking, beating in the response, elliptical particle motion, and significant torsion during strong shaking at the top of the concrete piers which extend from the basement to the second floor. The analyses conducted indicate that the response of the structure was elastic in all recorded earthquakes to date, including Northridge. Also, several simple damage detection methods employed did not indicate any structural damage or connection fractures. The combination of a large, real structure and low instrumentation density precluded the application of many recently proposed advanced damage detection methods in this case study. Overall, however, the findings of this study are consistent with the limited code-compliant postearthquake intrusive inspections conducted after the Northridge earthquake, which found no connection fractures or other structural damage. ?? ASCE.

  20. The evaluation of damage mechanism of unreinforced masonry buildings after Van (2011) and Elazig (2010) Earthquakes

    International Nuclear Information System (INIS)

    Güney, D; Aydin, E; Öztürk, B

    2015-01-01

    On March 8 th , 2010 Karakocan-Elazig earthquake of magnitude 6.0 occurred at a region where masonry and adobe construction is very common. Karakocan-Elazig is located in a high seismicity region on Eastern Anatolian Fault System (EAFS). Due to the earthquake, 42 people were killed and 14’113 buildings were damaged. Another city, Van located at South east of Turkey is hit by earthquakes with M = 7.2 occurred on October 23 rd , 2011 at 13:41 (local time), whose epicenter was about 16 km north of Van (Tabanli village) and M = 5.6 on November 9 th , 2011 with an epicenter near the town of Edremit, south of Van and caused the loss of life and heavy damages. Both earthquakes killed 644 people and 2608 people were injured. Approximately 10’000 buildings were seriously damaged. There are many traditional types of structures existing in the region hit by earthquakes (both Van and Elazig). These buildings were built as adobe, unreinforced masonry or mixed type. These types of buildings are very common in rural areas (especially south and east) of Turkey because of easy workmanship and cheap construction cost. Many of those traditional type structures experienced serious damages. The use of masonry is very common in some of the world's most hazard-prone regions, such as in Latin America, Africa, the Indian subcontinent and other parts of Asia, the Middle East, and southern Europe. Based on damage and failure mechanism of those buildings, the parameters affecting the seismic performance of those traditional buildings are analyzed in this paper. The foundation type, soil conditions, production method of the masonry blocks, construction method, the geometry of the masonry walls, workmanship quality, existence of wooden beams, type of roof, mortar between adobe blocks are studied in order to understand the reason of damage for these types of buildings. (paper)

  1. Satellite Image Classification of Building Damages Using Airborne and Satellite Image Samples in a Deep Learning Approach

    Science.gov (United States)

    Duarte, D.; Nex, F.; Kerle, N.; Vosselman, G.

    2018-05-01

    The localization and detailed assessment of damaged buildings after a disastrous event is of utmost importance to guide response operations, recovery tasks or for insurance purposes. Several remote sensing platforms and sensors are currently used for the manual detection of building damages. However, there is an overall interest in the use of automated methods to perform this task, regardless of the used platform. Owing to its synoptic coverage and predictable availability, satellite imagery is currently used as input for the identification of building damages by the International Charter, as well as the Copernicus Emergency Management Service for the production of damage grading and reference maps. Recently proposed methods to perform image classification of building damages rely on convolutional neural networks (CNN). These are usually trained with only satellite image samples in a binary classification problem, however the number of samples derived from these images is often limited, affecting the quality of the classification results. The use of up/down-sampling image samples during the training of a CNN, has demonstrated to improve several image recognition tasks in remote sensing. However, it is currently unclear if this multi resolution information can also be captured from images with different spatial resolutions like satellite and airborne imagery (from both manned and unmanned platforms). In this paper, a CNN framework using residual connections and dilated convolutions is used considering both manned and unmanned aerial image samples to perform the satellite image classification of building damages. Three network configurations, trained with multi-resolution image samples are compared against two benchmark networks where only satellite image samples are used. Combining feature maps generated from airborne and satellite image samples, and refining these using only the satellite image samples, improved nearly 4 % the overall satellite image

  2. Evaluation of damages of airplane crash in European Advanced Boiling Water Reactor (EU-ABWR)

    International Nuclear Information System (INIS)

    Kamei, Kazuhiro; Tanoue, Tetsuharu; Kataoka, Kazuyoshi; Jimbo, Masakazu

    2011-01-01

    European Advanced Boiling Water Reactor (EU-ABWR) is developed by Toshiba. EU-ABWR accommodates an armored reactor building against Airplane Crash (APC), severe accident mitigation systems, N+2 principle in safety systems and a large output of 1600 MWe. Thanks to above mentioned features, EU-ABWR's design objectives and principles are consistent with safety requirements in an European market. In this paper, evaluation of damages induced by APC has been summarized. (author)

  3. Estimating shaking-induced casualties and building damage for global earthquake events: a proposed modelling approach

    Science.gov (United States)

    So, Emily; Spence, Robin

    2013-01-01

    Recent earthquakes such as the Haiti earthquake of 12 January 2010 and the Qinghai earthquake on 14 April 2010 have highlighted the importance of rapid estimation of casualties after the event for humanitarian response. Both of these events resulted in surprisingly high death tolls, casualties and survivors made homeless. In the Mw = 7.0 Haiti earthquake, over 200,000 people perished with more than 300,000 reported injuries and 2 million made homeless. The Mw = 6.9 earthquake in Qinghai resulted in over 2,000 deaths with a further 11,000 people with serious or moderate injuries and 100,000 people have been left homeless in this mountainous region of China. In such events relief efforts can be significantly benefitted by the availability of rapid estimation and mapping of expected casualties. This paper contributes to ongoing global efforts to estimate probable earthquake casualties very rapidly after an earthquake has taken place. The analysis uses the assembled empirical damage and casualty data in the Cambridge Earthquake Impacts Database (CEQID) and explores data by event and across events to test the relationships of building and fatality distributions to the main explanatory variables of building type, building damage level and earthquake intensity. The prototype global casualty estimation model described here uses a semi-empirical approach that estimates damage rates for different classes of buildings present in the local building stock, and then relates fatality rates to the damage rates of each class of buildings. This approach accounts for the effect of the very different types of buildings (by climatic zone, urban or rural location, culture, income level etc), on casualties. The resulting casualty parameters were tested against the overall casualty data from several historical earthquakes in CEQID; a reasonable fit was found.

  4. Ensuring the long service life of unheated buildings. Evaluation methods to avoid moisture damage in unheated buildings

    Energy Technology Data Exchange (ETDEWEB)

    Viljanen, M.; Bergman, J.; Grabko, S.; Lu Xiaoshu; Yrjoelae, R.

    1999-07-01

    Buildings are normally designed according to an indoor temperature level of +20 deg C and to a certain ventilation rate, which depends on the activities in the building. When normal use has been interrupted and the building is left totally unheated, the indoor conditions will follow the outdoor conditions with a certain lag depending on the structures of the building and the amount of ventilation. The lowering of a room temperature increases the risk of mould and damage to structures. The research work was divided into the theoretical part and the field measurements. The objective of the research was to increase our knowledge of the thermal and moisture technical behaviour of unheated buildings, to determine the suitable methods for ensuring the preservation of buildings and their efficiency, and to develop guidelines for selecting different methods and maintenance of buildings. In the theoretical part of the research both analytical and numerical calculation programs were developed. The analytical method is based on the thermostability theory of a room and the numerical method on heat and moisture balance equations of the building. In the numerical calculation program HMTB finite difference and element methods were exploited. The accuracy of the calculation methods was compared with the field measurement results. The field measurements were carried out in eight buildings, which consisted of heated office buildings and unheated farm houses and museum buildings. The measurements were carried out during 1997 and 1998. The annual temperature range indoors in the unheated buildings was from -15 deg C to 27 deg C and the relative humidity range from 30% to 98%. In the heated buildings relative humidity was lower. The highest levels of relative humidity in the unheated buildings were in winter and in the heated buildings in autumn. The climatic differences between districts were great. Heavy rain periods increased the moisture level of indoor air by about 10 %. The risk

  5. Piezoelectric dynamic strain monitoring for detecting local seismic damage in steel buildings

    International Nuclear Information System (INIS)

    Kurata, Masahiro; Li, Xiaohua; Fujita, Kohei; Yamaguchi, Mayako

    2013-01-01

    This research presents a methodology for damage detection along with a sensing system for monitoring seismic damage in steel buildings. The system extracts the location and extent of local damage, such as fracture at a beam–column connection, from changes in the bending moment distribution in a steel moment-resisting frame. We developed a dynamic strain-based sensing system utilizing piezoelectric film sensors and wireless sensing techniques to estimate the bending moments resisted by individual structural members under small amplitude loadings such as ambient vibrations and minor earthquakes. We introduce a new damage index that extracts local damage information from the comparative study of the dynamic strain responses of the structural members before and after a large earthquake event. The damage detection scheme was examined both analytically and numerically using a simple frame example. Then, the entire local damage detection scheme was verified through a series of vibration tests using a one-quarter-scale steel testbed that simulated seismic damage at member ends. (paper)

  6. Empirical Fragility Analysis of Buildings and Boats Damaged By the 2011 Great East Japan Tsunami and Their Practical Application

    Science.gov (United States)

    Suppasri, A.; Charvet, I.; Leelawat, N.; Fukutani, Y.; Muhari, A.; Futami, T.; Imamura, F.

    2014-12-01

    This study focused in turn on detailed data of buildings and boats damage caused by the 2011 tsunami in order to understand its main causes and provide damage probability estimates. Tsunami-induced building damage data was collected from field surveys, and includes inundation depth, building material, number of stories and occupancy type for more than 80,000 buildings. Numerical simulations with high resolution bathymetry and topography data were conducted to obtain characteristic tsunami measures such as flow velocity. These data were analyzed using advanced statistical methods, ordinal regression analysis to create not only empirical 2D tsunami fragility curves, but also 3D tsunami fragility surfaces for the first time. The effect of floating debris was also considered, by using a binary indicator of debris impact based on the proximity of a structure from a debris source (i.e. washed away building). Both the 2D and 3D fragility analyses provided results for each different building damage level, and different topography. While 2D fragility curves provide easily interpretable results relating tsunami flow depth to damage probability for different damage levels, 3D fragility surfaces allow for several influential tsunami parameters to be taken into account thus reduce uncertainty in the probability estimations. More than 20,000 damaged boats were used in the analysis similar to the one carried out on the buildings. Detailed data for each boat comprises information on the damage ratio (paid value over insured value), tonnage, engine type, material type and damage classification. The 2D and 3D fragility analyses were developed using representative tsunami heights for each port obtained from field surveys and flow velocities obtained from the aforementioned simulations. The results are currently being adapted for practical disaster mitigation. They are being integrated with the probabilistic tsunami hazard analysis, in order to create offshore and onshore

  7. Salt damage and RH changes: The case of the Waag Building in Amsterdam

    NARCIS (Netherlands)

    Hees, R.P.J. van; Lubelli, B.A.

    2007-01-01

    Changes in the air MM can cause damage to building materials contaminated with hygroscopic saus, even in the absence of any other moishwe source. This phenomenon has been observed in the case of the iflag build ing in Amsterdam, affècted by severe salt decay. The investigation, canied out by means

  8. Associations between Fungal Species and Water-Damaged Building Materials

    DEFF Research Database (Denmark)

    Andersen, Birgitte; Frisvad, Jens Christian; Søndergaard, Ib

    2011-01-01

    melleus, Aspergillus niger, Aspergillus ochraceus, Chaetomium spp., Mucor racemosus, Mucor spinosus, and concrete and other floor-related materials. These results can be used to develop new and resistant building materials and relevant allergen extracts and to help focus research on relevant mycotoxins...

  9. Mould growth on building materials

    DEFF Research Database (Denmark)

    Fog Nielsen, K.

    Mould growth in buildings is associated with adverse health effects among the occupants of the building. However actual growth only occurs in damp and water-damaged materials, and is an increasing problem in Denmark, due to less robust constructions, inadequate maintenance, and too little...

  10. Discussing simply waste water treatment in building green mine

    International Nuclear Information System (INIS)

    Zhou Yousheng

    2010-01-01

    Analysis simplfy it is important and necessary that uran ore enterprise build the green mine .According to focusing on waste water treatment in building green mine of some uran ore enterprise,analysis the problem in treating mine water, technics waste water, tailings water before remoulding the system of waster water treatment, evaluate the advanced technics, satisfy ability, steady effect, reach the mark of discharge. According to the experimental unit of building the green mine,some uran ore enterprise make the waster water reaching the mark of discharge after remoulding the system of waster water treatment.It provides valuable experienceto uran ore enterprise in building green mine. (authors)

  11. DEPENDENCE OF DISTRIBUTION FUNCTION OF COMMERCIAL DAMAGES DUE TO POSSIBLE EARTHQUAKES ON THE CLASS OF SEISMIC RESISTANCE OF A BUILDING

    Directory of Open Access Journals (Sweden)

    Hanzada R. Zajnulabidova

    2017-01-01

    Full Text Available Abstract. Objectives To determine the damage probability of earthquakes of different intensities on the example of a real projected railway station building having a framework design scheme based on the density function of damage distribution. Methods Uncertainty, always existing in nature, invalidates a deterministic approach to the assessment of territorial seismic hazards and, consequently, seismic risk. In this case, seismic risk assessment can be carried out on a probabilistic basis. Thus, the risk will always be there, but it must be minimised. The task of optimising the reinforcement costs is solved by using the density distribution function for seismic effects of varying intensity, taking into account the degree of building responsibility. Results The distribution functions of the expected damage for a building with a reinforced concrete frame located in a highly seismic region with a repetition of 9-point shocks every 500 years and 10-point shocks once every 5000 years are constructed. A significant effect of the seismic resistance class of a building on the form of the distribution functions is shown. For structures of a high seismic resistance class, not only is the seismic risk reduced, but also the variance of the expected damage. From the graphs obtained, it can be seen that the seismic resistance class significantly affects the damage distribution. At a probability of 0.997, the expected damage for a non-reinforced building will exceed 43%; for a reinforced one it is only 10%. It also follows from the graphs that the variance of the damage magnitude decreases with the growth of the seismic resistance class of the building. This fact is an additional incentive for investing in antiseismic reinforcement of buildings. Conclusion The study shows the expediency of working with the damage density distribution function when managing seismic risk. In this case, it becomes possible to strengthen the building with a specified probability of

  12. Forecasting Frost Damage: Follow the Water

    Science.gov (United States)

    Rempel, A. W.

    2015-12-01

    Frost damage takes place when the pressure exerted against pore walls exceeds the cohesive strength of water-infiltrated rock and causes cracks to extend. Elegant theoretical treatments supported by meticulous field and laboratory observations have combined to unravel the basic mechanical and thermodynamic controls in idealized systems. Frost damage is most vigorous when conditions are cold enough that the net pressure exerted against the pore walls can cause crack extension, yet warm enough to enable the flow that supplies further ice growth in the newly opened space. This insight is applied here to develop practical geomorphic process laws for the effects of frost damage at the larger scales that are relevant for describing the evolution of landscapes. To this end, a direct connection is made between the intensity of frost damage and the porosity increase that results from gradients in water flux under conditions that are cold enough for ice-rock interactions to propagate cracks. This implies that the annual temperature variation at the ground surface can be combined with considerations of heat and mass transport to derive rigorous forecasts of the potential for frost damage that are tied to the increases in water mass that accompany solidification in porous rock. As an example, the image shows the depth-integrated porosity change λ promoted by crack growth at temperatures colder than -ΔTc over an annual cycle for different choices of mean annual temperature MAT and surface amplitude A (assuming a thermal diffusivity of 1 mm2/s and a power-law relationship between permeability and undercooling with exponent α=4, such that a base value of 10-14m2 is reached at a reference undercooling of 0.1 ºC). The abrupt onset in cracking once MAT decreases below a threshold is produced by the requirement that undercooling surpass ΔTc in order to generate sufficient pressures to propagate cracks. The eventual reduction and gradual tail in λ at colder MAT is produced by

  13. Multivariate pluvial flood damage models

    International Nuclear Information System (INIS)

    Van Ootegem, Luc; Verhofstadt, Elsy; Van Herck, Kristine; Creten, Tom

    2015-01-01

    Depth–damage-functions, relating the monetary flood damage to the depth of the inundation, are commonly used in the case of fluvial floods (floods caused by a river overflowing). We construct four multivariate damage models for pluvial floods (caused by extreme rainfall) by differentiating on the one hand between ground floor floods and basement floods and on the other hand between damage to residential buildings and damage to housing contents. We do not only take into account the effect of flood-depth on damage, but also incorporate the effects of non-hazard indicators (building characteristics, behavioural indicators and socio-economic variables). By using a Tobit-estimation technique on identified victims of pluvial floods in Flanders (Belgium), we take into account the effect of cases of reported zero damage. Our results show that the flood depth is an important predictor of damage, but with a diverging impact between ground floor floods and basement floods. Also non-hazard indicators are important. For example being aware of the risk just before the water enters the building reduces content damage considerably, underlining the importance of warning systems and policy in this case of pluvial floods. - Highlights: • Prediction of damage of pluvial floods using also non-hazard information • We include ‘no damage cases’ using a Tobit model. • The damage of flood depth is stronger for ground floor than for basement floods. • Non-hazard indicators are especially important for content damage. • Potential gain of policies that increase awareness of flood risks

  14. Multivariate pluvial flood damage models

    Energy Technology Data Exchange (ETDEWEB)

    Van Ootegem, Luc [HIVA — University of Louvain (Belgium); SHERPPA — Ghent University (Belgium); Verhofstadt, Elsy [SHERPPA — Ghent University (Belgium); Van Herck, Kristine; Creten, Tom [HIVA — University of Louvain (Belgium)

    2015-09-15

    Depth–damage-functions, relating the monetary flood damage to the depth of the inundation, are commonly used in the case of fluvial floods (floods caused by a river overflowing). We construct four multivariate damage models for pluvial floods (caused by extreme rainfall) by differentiating on the one hand between ground floor floods and basement floods and on the other hand between damage to residential buildings and damage to housing contents. We do not only take into account the effect of flood-depth on damage, but also incorporate the effects of non-hazard indicators (building characteristics, behavioural indicators and socio-economic variables). By using a Tobit-estimation technique on identified victims of pluvial floods in Flanders (Belgium), we take into account the effect of cases of reported zero damage. Our results show that the flood depth is an important predictor of damage, but with a diverging impact between ground floor floods and basement floods. Also non-hazard indicators are important. For example being aware of the risk just before the water enters the building reduces content damage considerably, underlining the importance of warning systems and policy in this case of pluvial floods. - Highlights: • Prediction of damage of pluvial floods using also non-hazard information • We include ‘no damage cases’ using a Tobit model. • The damage of flood depth is stronger for ground floor than for basement floods. • Non-hazard indicators are especially important for content damage. • Potential gain of policies that increase awareness of flood risks.

  15. A Water-Damaged Home and Health of Occupants: A Case Study

    International Nuclear Information System (INIS)

    Thrasher, J.D.; Gray, M.R.; Kilburn, K.H.; Kilburn, K.H.; Dennis, D.P.; Yu, A.

    2012-01-01

    A family of five and pet dog who rented a water-damaged home and developed multiple health problems. The home was analyzed for species of mold and bacteria. The diagnostics included MRI for chronic sinusitis with ENT and sinus surgery, and neurological testing for neuro cognitive deficits. Bulk samples from the home, tissue from the sinuses, urine, nasal secretions, placenta, umbilical cord, and breast milk were tested for the presence of trichothecene, aflatoxins, and Ochratoxin A. The family had the following diagnosed conditions: chronic sinusitis, neurological deficits, coughing with wheeze, nose bleeds, and fatigue among other symptoms. An infant was born with a total body flare, developed multiple Cafe-au-Lait pigmented skin spots and diagnoses with NF1 at age 2. The mycotoxins were detected in bulk samples, urine and nasal secretions, breast milk, placenta, and umbilical cord. Pseudomonas aueroginosa, Acinetobacter, Penicillium, and Aspergillus fumigatus were cultured from nasal secretions (father and daughter). RT-PCR revealed A. fumigatus DNA in sinus tissues of the daughter. The dog had 72 skin lesions (sebaceous glands and lipomas) from which trichothecene and ochratoxin A. were detected. The health of the family is discussed in relation to the most recent published literature regarding microbial contamination and toxic by-products present in water-damaged buildings.

  16. A Water-Damaged Home and Health of Occupants: A Case Study

    Directory of Open Access Journals (Sweden)

    Jack Dwayne Thrasher

    2012-01-01

    Full Text Available A family of five and pet dog who rented a water-damaged home and developed multiple health problems. The home was analyzed for species of mold and bacteria. The diagnostics included MRI for chronic sinusitis with ENT and sinus surgery, and neurological testing for neurocognitive deficits. Bulk samples from the home, tissue from the sinuses, urine, nasal secretions, placenta, umbilical cord, and breast milk were tested for the presence of trichothecenes, aflatoxins, and Ochratoxin A. The family had the following diagnosed conditions: chronic sinusitis, neurological deficits, coughing with wheeze, nose bleeds, and fatigue among other symptoms. An infant was born with a total body flare, developed multiple Cafe-au-Lait pigmented skin spots and diagnoses with NF1 at age 2. The mycotoxins were detected in bulk samples, urine and nasal secretions, breast milk, placenta, and umbilical cord. Pseudomonas aueroginosa, Acinetobacter, Penicillium, and Aspergillus fumigatus were cultured from nasal secretions (father and daughter. RT-PCR revealed A. fumigatus DNA in sinus tissues of the daughter. The dog had 72 skin lesions (sebaceous glands and lipomas from which trichothecenes and ochratoxin A. were detected. The health of the family is discussed in relation to the most recent published literature regarding microbial contamination and toxic by-products present in water-damaged buildings.

  17. Assessment of the material properties of a fire damaged building

    Directory of Open Access Journals (Sweden)

    Oladipupo OLOMO

    2012-12-01

    Full Text Available This study identifies a process for assessing the material properties of a fire damaged building so as to determine whether the remains can be utilized in construction or be demolished. Physical and chemical analysis were carried out on concrete and steel samples taken from various elements of the building after thorough visual inspection of the entire building had been conducted. The physical (non-destructive tests included the Schmidt hammer and ultrasonic pulse velocity tests on the concrete samples, tensile strength test on the steel samples and chemical tests involving the assessment of the quantities of cement, sulphates and chloride concentrations in the samples. A redesign of the building elements was also carried out and the results were compared with the existing design. The non-destructive test results indicated compressive strengths as low as 9.9 N/mm2, the tensile strength test indicated a maximum strength of 397.48 N/mm2 and the chemical test indicated chloride contents as high as 0.534 g per gramme of concrete. These properties deviated significantly from standard requirements. Based on these results, it was concluded that the remains of the building should be demolished.

  18. The classification, recording, databasing and use of information about building damage caused by subsidence and landslides

    OpenAIRE

    Cooper, Anthony

    2008-01-01

    Building damage as a result of subsidence and lateral movement can be caused by numerous mechanisms including mining, dissolution of soluble rocks, shrink–swell of clays and landslides. In many instances, the distribution and severity of the damage caused can be diagnostic of the underlying geological condition and can be used as an aid to geological and geomorphological mapping. Many rigid buildings are sensitive to movement, meaning that careful surveys can delineate fine details that can b...

  19. Gas and water permeability of concrete for reactor buildings small specimens

    International Nuclear Information System (INIS)

    Mills, R.H.

    1986-03-01

    The effect on permeability of artifical aging by drying shrinkage and by freeze-thaw was determined by observing mass transfer of gas and water under a pressure gradient. It was found that damage due to freeze-thaw was negligible but that cracking around aggregate caused by drying shrinkage resulted in significantly increased permeability to both gas and water. The absence of freeze-thaw damage was attributed to self-dessication. Since the concrete was not exposed to an external source of water, the chemical reaction was sustained by consumption of mixing water. The resulting air voids were, apparently, sufficient to absorb expansive pressures due to ice formation. The response to lateral prestress was different for cracked and uncracked concrete. Although, in all cases, increased prestress resulted in reduced leakage, the effect was stronger in cracked concrete. Mean pore diameter as determined by gas diffusion was not, however, substantially affected because the leakage in cracked concrete remained very low. Reinforcing steel did not have a great influence on permeability of small specimens. Gas transmission through concrete was strongly influenced by moisture content. Free moisture constituted a barrier to gas flow, acting as a virtual solid. This is important since aging of concrete results in reduced free moisture. Ultrasonic pulse velocity appeared to vary with moisture content and porosity of concrete in the same way as gas permeability and gave promise of being effective for in-situ monitoring of concrete in reactor buildings

  20. Building Damage Estimation by Integration of Seismic Intensity Information and Satellite L-band SAR Imagery

    Directory of Open Access Journals (Sweden)

    Nobuoto Nojima

    2010-09-01

    Full Text Available For a quick and stable estimation of earthquake damaged buildings worldwide, using Phased Array type L-band Synthetic Aperture Radar (PALSAR loaded on the Advanced Land Observing Satellite (ALOS satellite, a model combining the usage of satellite synthetic aperture radar (SAR imagery and Japan Meteorological Agency (JMA-scale seismic intensity is proposed. In order to expand the existing C-band SAR based damage estimation model into L-band SAR, this paper rebuilds a likelihood function for severe damage ratio, on the basis of dataset from Japanese Earth Resource Satellite-1 (JERS-1/SAR (L-band SAR images observed during the 1995 Kobe earthquake and its detailed ground truth data. The model which integrates the fragility functions of building damage in terms of seismic intensity and the proposed likelihood function is then applied to PALSAR images taken over the areas affected by the 2007 earthquake in Pisco, Peru. The accuracy of the proposed damage estimation model is examined by comparing the results of the analyses with field investigations and/or interpretation of high-resolution satellite images.

  1. Application of BIM Technology in Building Water Supply and Drainage Design

    Science.gov (United States)

    Wei, Tianyun; Chen, Guiqing; Wang, Junde

    2017-12-01

    Through the application of BIM technology, the idea of building water supply and drainage designers can be related to the model, the various influencing factors to affect water supply and drainage design can be considered more comprehensively. BIM(Building information model) technology assist in improving the design process of building water supply and drainage, promoting the building water supply and drainage planning, enriching the building water supply and drainage design method, improving the water supply and drainage system design level and building quality. Combined with fuzzy comprehensive evaluation method to analyze the advantages of BIM technology in building water supply and drainage design. Therefore, application prospects of BIM technology are very worthy of promotion.

  2. Infrared survey of 50 buildings constructed during 100 years: thermal performances and damage conditions

    Science.gov (United States)

    Ljungberg, Sven-Ake

    1995-03-01

    Different building constructions and craftsmanship give rise to different thermal performance and damage conditions. The building stock of most industrial countries consists of buildings of various age, and constructions, from old historic buildings with heavy stone or wooden construction, to new buildings with heavy or light concrete construction, or modern steel or wooden construction. In this paper the result from a detailed infrared survey of 50 buildings from six Swedish military camps is presented. The presentation is limited to a comparison of thermal performance and damage conditions of buildings of various ages, functions, and constructions, of a building period of more than 100 years. The result is expected to be relevant even to civilian buildings. Infrared surveys were performed during 1992-1993, with airborne, and mobile short- and longwave infrared systems, out- and indoor thermography. Interpretation and analysis of infrared data was performed with interactive image and analyzing systems. Field inspections were carried out with fiber optics system, and by ocular inspections. Air-exchange rate was measured in order to quantify air leakages through the building envelope, indicated in thermograms. The objects studied were single-family houses, barracks, office-, service-, school- and exercise buildings, military hotels and restaurants, aircraft hangars, and ship factory buildings. The main conclusions from this study are that most buildings from 1880 - 1940 have a solid construction with a high quality of craftsmanship, relatively good thermal performance, due to extremely thick walls, and adding insulation at the attic floor. From about 1940 - 1960 the quality of construction, thermal performance and craftsmanship seem to vary a lot. Buildings constructed during the period of 1960 - 1990 have in general the best thermal performance due to a better insulation capacity, however, also one finds here the greatest variety of problems. The result from this

  3. Damage functions for the vulnerability assessment of masonry buildings subjected to tunneling

    NARCIS (Netherlands)

    Giardina, C.; Hendriks, M.A.N.; Rots, J.G.

    2015-01-01

    This paper describes a new framework for the assessment of potential damage caused by tunneling-induced settlement to surface masonry buildings. Finite element models in two and three dimensions, validated through comparison with experimental results and field observations, are used to investigate

  4. Contribution to the damage measurement of reinforced concrete buildings under seismic solicitations: proposal of an improvement for the evaluation of the damaging potential of a signal and of the damage for the girders structures: introduction to the reliability analysis of the damage in terms of the damaging potential of a seismic signal

    International Nuclear Information System (INIS)

    Naze, P.A.

    2004-12-01

    Building damage measurement during and after an earthquake remains an economical as well as technical stake as difficult to cope with as the problem it raises all the more because its importance depends on the field or the building function: civil, medical, military, nuclear... Even building ruin remains one of the most critical diagnosis to establish. Then since prediction of earthquake still remains impossible, foreseeing structural damages due to seismic motion has become a key point in earthquake engineering. This work aims at evaluating the relevance of classical seismic signal damaging potential indices and at proposing improvement of these indices in order to provide better prediction of structural damage due to earthquake. The first part supplies a non exhaustive state of the art of main Damaging Potential Indices IP and Damage Indices ID used in earthquake engineering. In the second part, IP/ID correlations results are analysed in order to evaluate IP relevance, to justify displacement based approach use (capacity spectrum method) for damage prediction and to make good the proposal for improvement of Damaging Potential Index. But studding seismic signal damaging potential is usually not enough to foresee damage firstly because scalar representation of damaging potential is not easy to link to physics reality and secondly because of damage scattering often observed for a single value of seismic signal damaging potential. In the same way, a single damage index value may correspond to very different structural damage states. Hence, this work carries on with a contribution to damage index reliability improvement, able to detect real structural damage appearance as well as to quantify this damage by associating the distance between one structural sate and the structural collapse, defined as an instability. (author)

  5. Drinking Water Quality in Hospitals and Other Buildings

    Science.gov (United States)

    Drinking water quality entering large buildings is generally adequately controlled by the water utility, but localized problems may occur within building or “premise” plumbing. Particular concerns are loss of disinfectant residual and temperature variability, which may enhance pa...

  6. GPS on Every Roof, GPS Sensor Network for Post-Seismic Building-Wise Damage Identification

    Directory of Open Access Journals (Sweden)

    Kenji Oguni

    2013-12-01

    Full Text Available Development of wireless sensor network equipped with GPS for post-seismic building-wise damage identification is presented in this paper. This system is called GPS on Every Roof. Sensor node equipped with GPS antenna and receiver is installed on the top of the roof of each and every building. The position of this sensor node is measured before and after earthquake. The final goal of this system is to i identify the displacement of the roof of each house and ii collect the information of displacement of the roof of the houses through wireless communication. Superposing this information on GIS, building-wise damage distribution due to earthquake can be obtained. The system overview, hardware and some of the key components of the system such as on-board GPS relative positioning algorithm to achieve the accuracy in the order of several centimeters are described in detail. Also, the results from a field experiment using a wireless sensor network with 39 sensor nodes are presented.

  7. A Review of Methodologies on Vulnerability Assessment of Buildings to Tsunami Damage

    Science.gov (United States)

    Gunasekera, R.; Rosetto, T.; Tabuchi, S.; Suppasri, A.; Futami, T.; Scott, I.; Maegawa, H.

    2012-04-01

    The infrequency, suddenness and violence tsunamis has led to a lack of knowledge on tsunami and lack of data available for the calibration of numerical models particularly in relation to tsunami damage. Therefore, there are very few tsunami structural vulnerability studies available. Of the available literature, most of these started after the disastrous 2004 Indian Ocean event. Most of fragility curves have been developed in some areas struck by the 2004 tsunami, which are very different in architecture and engineering respect to the US, Japanese or European ones. This review aims to highlight the strengths and weaknesses of current knowledge on tsunami fragility by critically assessing several fragility curves based on post tsunami damage surveys in Chile, Japan (including initial findings of the March 2011 event), Samoa, Sri Lanka and Thailand. It is observed that there is no consensus on how to derive tsunami fragility curves. Most of the examined relationships are seen to relate to residential buildings, and, due to the location of recent tsunami occurrences, they mostly represent non-engineered buildings (i.e. all use data from Thailand, Sri Lanka, Samoa, or Sumatra), which limits their usefulness. In the absence of a good understanding of tsunami actions on buildings most existing fragility relationships adopt inundation depth as the hazard parameter in the vulnerability function, which does not account for the other components of onshore flow contributing to tsunami loads on buildings, such as flow velocity.

  8. 32 CFR 644.554 - Insurance against loss or damages to buildings and improvements by fire or acts of God.

    Science.gov (United States)

    2010-07-01

    ... 32 National Defense 4 2010-07-01 2010-07-01 true Insurance against loss or damages to buildings and improvements by fire or acts of God. 644.554 Section 644.554 National Defense Department of... Procedure § 644.554 Insurance against loss or damages to buildings and improvements by fire or acts of God...

  9. An attempt of using straight-line information for building damage detection based only on post-earthquake optical imagery

    International Nuclear Information System (INIS)

    Dong, Laigen; Ye, Yuanxin; Shan, Jie

    2014-01-01

    It is important to grasp damage information in stricken areas after an earthquake in order to perform quick rescue and recovery activities. Recent research into remote sensing techniques has shown significant ability to generate quality damage information. The methods based on only post-earthquake data are widely researched especially because there are no pre-earthquake reference data in many cities of the world. This paper addresses a method for detection of damaged buildings using only post-event satellite imagery so that scientists and researchers can take advantage of the ability of helicopters and airplanes to fly over the damage faster. Statistical information of line segments extracted from post-event satellite imagery, such as mean length (ML) and weighted tilt angel standard deviation (WTASD), are used for discriminating the damaged and undamaged buildings

  10. An Assessment of the Effectiveness of Tree-Based Models for Multi-Variate Flood Damage Assessment in Australia

    Directory of Open Access Journals (Sweden)

    Roozbeh Hasanzadeh Nafari

    2016-07-01

    Full Text Available Flood is a frequent natural hazard that has significant financial consequences for Australia. In Australia, physical losses caused by floods are commonly estimated by stage-damage functions. These methods usually consider only the depth of the water and the type of buildings at risk. However, flood damage is a complicated process, and it is dependent on a variety of factors which are rarely taken into account. This study explores the interaction, importance, and influence of water depth, flow velocity, water contamination, precautionary measures, emergency measures, flood experience, floor area, building value, building quality, and socioeconomic status. The study uses tree-based models (regression trees and bagging decision trees and a dataset collected from 2012 to 2013 flood events in Queensland, which includes information on structural damages, impact parameters, and resistance variables. The tree-based approaches show water depth, floor area, precautionary measures, building value, and building quality to be important damage-influencing parameters. Furthermore, the performance of the tree-based models is validated and contrasted with the outcomes of a multi-parameter loss function (FLFArs from Australia. The tree-based models are shown to be more accurate than the stage-damage function. Consequently, considering more parameters and taking advantage of tree-based models is recommended. The outcome is important for improving established Australian flood loss models and assisting decision-makers and insurance companies dealing with flood risk assessment.

  11. Building damage assessment after the earthquake in Haiti using two postevent satellite stereo imagery and DSMs

    DEFF Research Database (Denmark)

    Tian, Jiaojiao; Nielsen, Allan Aasbjerg; Reinartz, Peter

    2015-01-01

    In this article, a novel after-disaster building damage monitoring method is presented. This method combines the multispectral imagery and digital surface models (DSMs) from stereo matching of two dates to obtain three kinds of changes: collapsed buildings, newly built buildings and temporary she...... changes after the 2010 Haiti earthquake, and the obtained results are further evaluated both visually and numerically....

  12. Radiation damage of uranium-thorium oxide, irradiated in water

    International Nuclear Information System (INIS)

    Bloem, P.J.C.; Nagel, W.; Plas, T. van der; Kema, N.V.

    1977-01-01

    A suspension in water of spherical particles of UO 2 -ThO 2 with diameter 5μm has been considered as the working fluid in an aqueous, homogeneous, thermal nuclear reactor. Irradiation experiments have shown that these particles suffer a gradual breakdown when irradiated in water. This behaviour is markedly different from that shown on irradiation in absence of water. As damage was defined the amount of solid dissolved by an etching liquid. Electron microscopic pictures showed that at higher irradiation temperatures in water the actual damage was larger than the etching values indicated. (orig.) [de

  13. Development of methods for assessing the vulnerability of Australian residential building stock to severe wind

    International Nuclear Information System (INIS)

    Wehner, Martin; Sandland, Carl; Edwards, Mark; Ginger, John; Holmes, John

    2010-01-01

    Knowledge of the degree of damage to residential structures expected from severe wind is used to study the benefits from adaptation strategies developed in response to expected changes in wind severity due to climate change. This study will inform government, the insurance industry and provide emergency services with estimates of expected damage. A series of heuristic wind vulnerability curves for Australian residential structures has been developed. In order to provide rigor to the heuristic curves and to enable quantitative assessment to be made of adaptation strategies, work has commenced to produce a simulation tool to quantitatively assess damage to buildings from severe wind. The simulation tool accounts for variability in wind profile, shielding, structural strength, pressure coefficients, building orientation, component self weights, debris damage and water ingress via a Monte Carlo approach. The software takes a component-based approach to modelling building vulnerability. It is based on the premise that overall building damage is strongly related to the failure of key components (i.e. connections). If these failures can be ascertained, and associated damage from debris and water penetration reliably estimated, scenarios of complete building damage can be assessed. This approach has been developed with varying degrees of rigor by researchers around the world and is best practice for the insurance industry.

  14. Automatic recognition of damaged town buildings caused by earthquake using remote sensing information: Taking the 2001 Bhuj, India, earthquake and the 1976 Tangshan, China, earthquake as examples

    Science.gov (United States)

    Liu, Jia-Hang; Shan, Xin-Jian; Yin, Jing-Yuan

    2004-11-01

    In the high-resolution images, the undamaged buildings generally show a natural textural feature, while the damaged or semi-damaged buildings always exhibit some low-grayscale blocks because of their coarsely damaged sections. If we use a proper threshold to classify the grayscale of image, some independent holes will appear in the damaged regions. By using such statistical information as the number of holes in every region, or the ratio between the area of holes and that of the region, etc, the damaged buildings can be separated from the undamaged, thus automatic detection of damaged buildings can be realized. Based on these characteristics, a new method to automatically detect the damage buildings by using regional structure and statistical information of texture is presented in the paper. In order to test its validity, 1-m-resolution iKonos merged image of the 2001 Bhuj earthquake and grayscale aerial photos of the 1976 Tangshan earthquake are selected as two examples to automatically detect the damaged buildings. Satisfied results are obtained.

  15. LOSS OF WATER IN PUBLIC BUILDINGS (ON THE EXAMPLE OF MGSU

    Directory of Open Access Journals (Sweden)

    Orlov Evgeniy Vladimirovich

    2016-09-01

    Full Text Available Any public building is a consumer of water resources. A huge amount of clean drinking water is used for various needs especially in buildings where there are a large number of people, for example, institutions of higher education. It should be noted that today all buildings must meet requirements for water conservation. This is because a large amount of drinking water is wasted. The author considers the problems characteristic of public buildings, because of which losses of water in the inner water supply systems happen. The variants are offered how to reduce wasteful expenses by installing contactless water intake devices, wastewater intake as well as water-saving headers and waterless urinals. The use of polymer materials and copper pipelines during reconstruction of the system in order to reduce water losses is justified.

  16. Adapting ecological risk valuation for natural resource damage assessment in water pollution.

    Science.gov (United States)

    Chen, Shuzhen; Wu, Desheng

    2018-07-01

    Ecological risk assessment can address requirements of natural resource damage assessment by quantifying the magnitude of possible damages to the ecosystem. This paper investigates an approach to assess water damages from pollution incident on the basis of concentrations of contaminants. The baseline of water pollution is determined with not-to-exceed concentration of contaminants required by water quality standards. The values of damage cost to water quality are estimated through sewage treatment cost. To get a reliable estimate of treatment cost, DEA is employed to classify samples of sewage plants based on their efficiency of sewage treatment. And exponential fitting is adopted to determine the relation between treatment cost and the decrease of COCs. The range of damage costs is determined through the fitting curves respectively based on efficient and inefficient samples. Copyright © 2018 Elsevier Inc. All rights reserved.

  17. Spinal column damage from water ski jumping.

    Science.gov (United States)

    Horne, J; Cockshott, W P; Shannon, H S

    1987-01-01

    We conducted a radiographic survey of 117 competitive water ski jumpers to determine whether this sport can cause spinal column damage and, if so, whether damage is more likely to occur in those who participate during the period of spinal growth and development (age 15 years or younger). We found a high prevalence of two types of abnormality: Scheuermann (adolescent) spondylodystrophy (present in 26% of the skiers) and vertebral body wedging (present in 34%). The prevalence of adolescent spondylodystrophy increased with the number of years of participation in the sport before age 15 years or less. Of those in this age group who had skied for 5 years or more, 57 showed adolescent spondylodystrophy; of those in the same age group who had skied for 9 years or more, 100% were affected. Wedged vertebrae increased as time of participation increased, regardless of the age at which exposure began. We conclude that competitive water ski jumping may damage the spinal column and that consideration should be given to regulating this sport, particularly for children.

  18. Spinal column damage from water ski jumping

    International Nuclear Information System (INIS)

    Horne, J.; Cockshott, W.P.; Shannon, H.S.

    1987-01-01

    We conducted a radiographic survey of 117 competitive water ski jumpers to determine whether this sport can cause spinal column damage and, if so, whether damage is more likely to occur in those who participate during the period of spinal growth and development (age 15 years or younger). We found a high prevalence of two types of abnormality: Scheuermann (adolescent) spondylodystrophy (present in 26% of the skiers) and vertebral body wedging (present in 34%). The prevalence of adolescent spondylodystrophy increased with the number of years of participation in the sport before age 15 years or less. Of those in this age group who had skied for 5 years or more, 57 showed adolescent spondylodystrophy; of those in the same age group who had skied for 9 years or more, 100% were affected. Wedged vertebrae increased as time of participation increased, regardless of the age at which exposure began. We conclude that competitive water ski jumping may damage the spinal column and that consideration should be given to regulating this sport, particularly for children. (orig.)

  19. Spinal column damage from water ski jumping

    Energy Technology Data Exchange (ETDEWEB)

    Horne, J.; Cockshott, W.P.; Shannon, H.S.

    1987-11-01

    We conducted a radiographic survey of 117 competitive water ski jumpers to determine whether this sport can cause spinal column damage and, if so, whether damage is more likely to occur in those who participate during the period of spinal growth and development (age 15 years or younger). We found a high prevalence of two types of abnormality: Scheuermann (adolescent) spondylodystrophy (present in 26% of the skiers) and vertebral body wedging (present in 34%). The prevalence of adolescent spondylodystrophy increased with the number of years of participation in the sport before age 15 years or less. Of those in this age group who had skied for 5 years or more, 57 showed adolescent spondylodystrophy; of those in the same age group who had skied for 9 years or more, 100% were affected. Wedged vertebrae increased as time of participation increased, regardless of the age at which exposure began. We conclude that competitive water ski jumping may damage the spinal column and that consideration should be given to regulating this sport, particularly for children. (orig.)

  20. Damage assessment of mission essential buildings based on simulation studies of low yield explosives

    Science.gov (United States)

    Allen, Thomas G. L.

    2006-04-01

    There has been a lack of investigations related to low yield explosives instigated by terrorist on small but high occupancy buildings. Also, mitigating the threat of terrorist attacks against high occupancy buildings with network equipment essential to the mission of an organization is a challenging task. At the same time, it is difficult to predict how, why, and when terrorists may attack theses assets. Many factors must be considered in creating a safe building environment. Although it is possible that the dominant threat mode may change in the future, bombings have historically been a favorite tactic of terrorists. Ingredients for homemade bombs are easily obtained on the open market, as are the techniques for making bombs. Bombings are easy and quick to execute. This paper discusses the problems with and provides insights of experience gained in analyzing small scale explosions on older military base buildings. In this study, we examine the placement of various bombs on buildings using the shock wave simulation code CTH and examine the damage effects on the interior of the building, particularly the damage that is incurred on a computer center. These simulation experiments provide data on the effectiveness of a building's security and an understanding of the phenomenology of shocks as they propagate through rooms and corridors. It's purpose is to motivate researchers to take the seriousness of small yield explosives on moderately sized buildings. Visualizations from this analysis are used to understand the complex flow of the air blasts around corridors and hallways. Finally, we make suggestions for improving the mitigation of such terrorist attacks. The intent of this study is not to provide breakthrough technology, but to provide a tool and a means for analyzing the material hardness of a building and to eventually provide the incentive for more security. The information mentioned in this paper is public domain information and easily available via the

  1. Method of decommissioning nuclear reactor building by utilizing sea water buyoancy

    International Nuclear Information System (INIS)

    Iwashima, Sumio; Ogoshi, Shigeru; Kobari, Shin-ichi.

    1989-01-01

    Upon dismantling nuclear reactor buildings, peripheral yards are excavated and channels leading to sea shore are formed. Since the outer walls of the reactor buildings are made of iron-reinforced concretes, the opening poritons are grouted with concretes to attain a tightly such closed structure that radioactive wastes, etc. in the inside are not flown out upon reactor discommisioning. Peripheral buildings at relatively low level of radiation contaminations are dismantled and withdrawn. The fundations of the nuclear reactor buildings were dug out and jacked to separate base rocks and the reactor buildings. Then, sea water is introduced into the water channels to entirely float up the buildings. A water gate is disposed in the water channel on the side of sea shore to control the level of sea water. The buildings are moved and guided to the sea shore and towed to a site optimum as a permanent storage area and then burried in that place. The operation period for the discommissioning work can greatly be shortened and the radiation dose and the amount of the wastes can be reduced. (T.M.)

  2. PHOSPHATE CHEMICALS FOR BUILDING POTABLE WATER TREATMENT

    Science.gov (United States)

    Buildings can contribute significant quantities of trace metal contamination to drinking water, particularly lead, copper and zinc. Discolored water may also result in corroded galvanized and steel plumbing and after prolonged stagnation times. To protect human health as well as ...

  3. A Review of the Mechanism of Injury and Treatment Approaches for Illness Resulting from Exposure to Water-Damaged Buildings, Mold, and Mycotoxins

    Directory of Open Access Journals (Sweden)

    Janette Hope

    2013-01-01

    Full Text Available Physicians are increasingly being asked to diagnose and treat people made ill by exposure to water-damaged environments, mold, and mycotoxins. In addition to avoidance of further exposure to these environments and to items contaminated by these environments, a number of approaches have been used to help persons affected by exposure to restore their health. Illness results from a combination of factors present in water-damaged indoor environments including, mold spores and hyphal fragments, mycotoxins, bacteria, bacterial endotoxins, and cell wall components as well as other factors. Mechanisms of illness include inflammation, oxidative stress, toxicity, infection, allergy, and irritant effects of exposure. This paper reviews the scientific literature as it relates to commonly used treatments such as glutathione, antioxidants, antifungals, and sequestering agents such as Cholestyramine, charcoal, clay and chlorella, antioxidants, probiotics, and induced sweating.

  4. Energy efficiency of elevated water supply tanks for high-rise buildings

    International Nuclear Information System (INIS)

    Cheung, C.T.; Mui, K.W.; Wong, L.T.

    2013-01-01

    Highlights: ► We evaluate energy efficiency for water supply tank location in buildings. ► Water supply tank arrangement in a building affects pumping energy use. ► We propose a mathematical model for optimal design solutions. ► We test the model with measurements in 22 Hong Kong buildings. ► A potential annual energy saving for Hong Kong is up to 410 TJ. -- Abstract: High-rise housing, a trend in densely populated cities around the world, increases the energy use for water supply and corresponding greenhouse gas emissions. This paper presents an energy efficiency evaluation measure for water supply system designs and a mathematical model for optimizing pumping energy through the arrangement of water tanks in a building. To demonstrate that the model is useful for establishing optimal design solutions that integrate energy consumption into urban water planning processes which cater to various building demands and usage patterns, measurement data of 22 high-rise residential buildings in Hong Kong are employed. The results show the energy efficiency of many existing high-rise water supply systems is about 0.25 and can be improved to 0.26–0.37 via water storage tank relocations. The corresponding annual electricity that can be saved is 160–410 TJ, a 0.1–0.3% of the total annual electricity consumption in Hong Kong.

  5. Flood damage curves for consistent global risk assessments

    Science.gov (United States)

    de Moel, Hans; Huizinga, Jan; Szewczyk, Wojtek

    2016-04-01

    Assessing potential damage of flood events is an important component in flood risk management. Determining direct flood damage is commonly done using depth-damage curves, which denote the flood damage that would occur at specific water depths per asset or land-use class. Many countries around the world have developed flood damage models using such curves which are based on analysis of past flood events and/or on expert judgement. However, such damage curves are not available for all regions, which hampers damage assessments in those regions. Moreover, due to different methodologies employed for various damage models in different countries, damage assessments cannot be directly compared with each other, obstructing also supra-national flood damage assessments. To address these problems, a globally consistent dataset of depth-damage curves has been developed. This dataset contains damage curves depicting percent of damage as a function of water depth as well as maximum damage values for a variety of assets and land use classes (i.e. residential, commercial, agriculture). Based on an extensive literature survey concave damage curves have been developed for each continent, while differentiation in flood damage between countries is established by determining maximum damage values at the country scale. These maximum damage values are based on construction cost surveys from multinational construction companies, which provide a coherent set of detailed building cost data across dozens of countries. A consistent set of maximum flood damage values for all countries was computed using statistical regressions with socio-economic World Development Indicators from the World Bank. Further, based on insights from the literature survey, guidance is also given on how the damage curves and maximum damage values can be adjusted for specific local circumstances, such as urban vs. rural locations, use of specific building material, etc. This dataset can be used for consistent supra

  6. Building dampness and mold in European homes in relation to climate, building characteristics and socio-economic status: The European Community Respiratory Health Survey ECRHS II.

    Science.gov (United States)

    Norbäck, D; Zock, J-P; Plana, E; Heinrich, J; Tischer, C; Jacobsen Bertelsen, R; Sunyer, J; Künzli, N; Villani, S; Olivieri, M; Verlato, G; Soon, A; Schlünssen, V; Gunnbjörnsdottir, M I; Jarvis, D

    2017-09-01

    We studied dampness and mold in homes in relation to climate, building characteristics and socio-economic status (SES) across Europe, for 7127 homes in 22 centers. A subsample of 3118 homes was inspected. Multilevel analysis was applied, including age, gender, center, SES, climate, and building factors. Self-reported water damage (10%), damp spots (21%), and mold (16%) in past year were similar as observed data (19% dampness and 14% mold). Ambient temperature was associated with self-reported water damage (OR=1.63 per 10°C; 95% CI 1.02-2.63), damp spots (OR=2.95; 95% CI 1.98-4.39), and mold (OR=2.28; 95% CI 1.04-4.67). Precipitation was associated with water damage (OR=1.12 per 100 mm; 95% CI 1.02-1.23) and damp spots (OR=1.11; 95% CI 1.02-1.20). Ambient relative air humidity was not associated with indoor dampness and mold. Older buildings had more dampness and mold (Prisk factors for dampness and mold in homes in Europe. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  7. Nanoscale study on water damage for different warm mix asphalt binders

    Directory of Open Access Journals (Sweden)

    Kefei Liu

    2016-11-01

    Full Text Available In order to analyze the water damage to different warm mix asphalt binders from the micro scale, five kinds of asphalt binders, 70#A base asphalt, sasobit warm mix asphalt, energy champion 120 °C (EC120 warm mix asphalt, aspha-min warm mix asphalt, sulfur-extended asphalt modifier (SEAM warm mix asphalt, under different conditions (dry/wet, original/aging are prepared for laboratory tests. The atomic force microscope (AFM is used to observe the surface properties and measure the adhesion force between the asphalt and the mineral aggregate. The obtained results show that under the dry condition aspha-min warm mix asphalt and SEAM warm mix asphalt show stronger adhesive ability with the mineral aggregate compared with other asphalt binders, but also have relatively large dispersion and fluctuation in the tested results; under the wet condition, aspha-min warm mix asphalt and SEAM warm mix asphalt show stronger water damage resistance ability. The EC120 warm mix asphalt and aspha-min warm mix asphalt are less sensitive to moist, and their corresponding adhesion force is less susceptible to the change of external moisture conditions, leading to a better ability to resist water erosion. The aging process significantly lowers the moisture erosion resistance ability, which further impairs the water damage resistance ability. The base asphalt is more sensitive to moisture and more vulnerable to water damage, no matter whether it is under original or aging conditions. The aging aspha-min warm mix asphalt has the least loss of adhesion force, the smallest dispersion of the tested adhesion force, the strongest water damage resistance ability, no matter it is dry or wet. Keywords: Road engineering, Warm mix asphalt, Moisture damage, Atomic force microscope, Microcosmic

  8. Multidisciplinary approach to evaluate flood damage for residential buildings: first results in Northern Italy

    Science.gov (United States)

    Luino, Fabio

    2015-04-01

    Flooding is the most common natural instability process in Italy. Flood damage are the results of land-use planning policies which, starting chiefly from the late 1950s and early 1960s, did not take into account the geomorphologic-hydraulic characteristics of an area or the its historical data on past flood events. Historically, compared to other areas, riverside property has always been less valuable. Unfortunately, year after year, even areas of high recreational and environmental value were intensely urbanized despite their being exposed to the threat of flooding. As the number of residential dwellings, infrastructure and industrial buildings increased, what was originally a hazard became a risk. For each flood event, the damage depends on the specific land-use of the area and subsequently on the elements at risk in the area involved and its vulnerability, expressed as a percentage of the element that has actually been lost during the event. This is why a comprehensive knowledge of the area it is so important for conducting a detailed survey of an area's structures and infrastructure and to evaluate the degree of vulnerability. This paper presents first results in Italy of the European Project called DAMAGE, the first attempt by the civil protection agencies of several European Union member states to devise a common methodology for the assessment of damage caused by natural or anthropic disasters. The main objective was to create an initial tool for practical and immediate application by civil protection agencies and local governments, to assess damage in a multidimensional perspective that takes into account infrastructure, the economy, the environment and social problems. Within the framework of a broad-based project for the evaluation and collection of reports on damage caused by floods, the CNR-IRPI of Turin and Regione Lombardia have directed attention to the town of Cittiglio (province of Varese), which was struck by severe flash flood in May 2002. One of

  9. Assessment of mean annual flood damage using simple hydraulic modeling and Monte Carlo simulation

    Science.gov (United States)

    Oubennaceur, K.; Agili, H.; Chokmani, K.; Poulin, J.; Marceau, P.

    2016-12-01

    Floods are the most frequent and the most damaging natural disaster in Canada. The issue of assessing and managing the risk related to this disaster has become increasingly crucial for both local and national authorities. Brigham, a municipality located in southern Quebec Province, is one of the heavily affected regions by this disaster because of frequent overflows of the Yamaska River reaching two to three times per year. Since Irene Hurricane which struck the region in 2011, causing considerable socio-economic damage, the implementation of mitigation measures has become a major priority for this municipality. To do this, a preliminary study to evaluate the risk to which this region is exposed is essential. Conventionally, approaches only based on the characterization of the hazard (e.g. floodplains extensive, flood depth) are generally adopted to study the risk of flooding. In order to improve the knowledge of this risk, a Monte Carlo simulation approach combining information on the hazard with vulnerability-related aspects has been developed. This approach integrates three main components: (1) hydrologic modelling aiming to establish a probability-discharge function which associate each measured discharge to its probability of occurrence (2) hydraulic modeling that aims to establish the relationship between the discharge and the water stage at each building (3) damage study that aims to assess the buildings damage using damage functions. The damage is estimated according to the water depth defined as the difference between the water level and the elevation of the building's first floor. The application of the proposed approach allows estimating the annual average cost of damage caused by floods on buildings. The obtained results will be useful for authorities to support their decisions on risk management and prevention against this disaster.

  10. Monitoring of Progressive Damage in Buildings Using Laser Scan Data

    Science.gov (United States)

    Puente, I.; Lindenbergh, R.; Van Natijne, A.; Esposito, R.; Schipper, R.

    2018-05-01

    Vulnerability of buildings to natural and man-induced hazards has become a main concern for our society. Ensuring their serviceability, safety and sustainability is of vital importance and the main reason for setting up monitoring systems to detect damages at an early stage. In this work, a method is presented for detecting changes from laser scan data, where no registration between different epochs is needed. To show the potential of the method, a case study of a laboratory test carried out at the Stevin laboratory of Delft University of Technology was selected. The case study was a quasi-static cyclic pushover test on a two-story high unreinforced masonry structure designed to simulate damage evolution caused by cyclic loading. During the various phases, we analysed the behaviour of the masonry walls by monitoring the deformation of each masonry unit. First a plane is fitted to the selected wall point cloud, consisting of one single terrestrial laser scan, using Principal Component Analysis (PCA). Second, the segmentation of individual elements is performed. Then deformations with respect to this plane model, for each epoch and specific element, are determined by computing their corresponding rotation and cloud-to-plane distances. The validation of the changes detected within this approach is done by comparison with traditional deformation analysis based on co-registered TLS point clouds between two or more epochs of building measurements. Initial results show that the sketched methodology is indeed able to detect changes at the mm level while avoiding 3D point cloud registration, which is a main issue in computer vision and remote sensing.

  11. A proposed method to assess the damage risk of future climate change to museum objects in historic buildings

    NARCIS (Netherlands)

    Huijbregts, Z.; Kramer, R.P.; Martens, M.H.J.; Schijndel, van A.W.M.; Schellen, H.L.

    2012-01-01

    Future climate change is expected to have a critical effect on valuable museum collections that are housed in historic buildings. Changes of the indoor environment in the building affect the microclimate around the museum objects and may cause damage to the collection. In this study, a method is

  12. A GASFLOW analysis of a steam explosion accident in a typical light-water reactor confinement building

    International Nuclear Information System (INIS)

    Travis, J.R.; Wilson, T.L.; Spore, J.W.; Lam, K.L.; Rao, D.V.

    1994-01-01

    Steam over-pressurization resulting from ex-vessel steam explosion (fuel-coolant interaction) may pose a serious challenge to the integrity of a typical light-water reactor confinement building. If the steam generation rate exceeds the removal capacity of the Airborne Activity Confinement System, confinement overpressurization occurs. Thus, there is a large potential for an uncontrolled and unfiltered release of fission products from the confinement atmosphere to the environment at the time of the steam explosion. The GASFLOW computer code was used to analyze the effects of a hypothetical steam explosion and the transport of steam and hydrogen throughout a typical light-water reactor confinement building. The effects of rapid pressurization and the resulting forces on the internal structures and the heat exchanger service bay hatch covers were calculated. Pressurization of the ventilation system and the potential damage to the ventilation fans and high-efficiency particulate air filters were assessed. Because of buoyancy forces and the calculated confinement velocity field, the hydrogen diffuses and mixes in the confinement atmosphere but tends to be transported to its upper region. (author). 2 refs., 14 figs

  13. A GASFLOW analysis of a steam explosion accident in a typical light-water reactor confinement building

    International Nuclear Information System (INIS)

    Travis, J.R.; Wilson, T.L.; Spore, J.W.; Lam, K.L.; Rao, D.V.

    1994-01-01

    Steam over-pressurization resulting from ex-vessel steam explosion (fuel-coolant interaction) may pose a serious challenge to the integrity of a typical light-water reactor confinement building. If the steam generation rate exceeds the removal capacity of the Airborne Activity Confinement System, confinement over pressurization occurs. Thus, there is a large potential for an uncontrolled and unfiltered release of fission products from the confinement atmosphere to the environment at the time of the steam explosion. The GASFLOW computer code was used to analyze the effects of a hypothetical steam explosion and the transport of steam and hydrogen throughout a typical light-water reactor confinement building. The effects of rapid pressurization and the resulting forces on the internal structures and the heat exchanger service bay hatch covers were calculated. Pressurization of the ventilation system and the potential damage to the ventilation fans and high-efficiency particulate air filters were assessed. Because of buoyancy forces and the calculated confinement velocity field, the hydrogen diffuses and mixes in the confinement atmosphere but tends to be transported to its upper region

  14. Application of Remote Sensing in Building Damages Assessment after Moderate and Strong Earthquake

    Science.gov (United States)

    Tian, Y.; Zhang, J.; Dou, A.

    2003-04-01

    - Earthquake is a main natural disaster in modern society. However, we still cannot predict the time and place of its occurrence accurately. Then it is of much importance to survey the damages information when an earthquake occurs, which can help us to mitigate losses and implement fast damage evaluation. In this paper, we use remote sensing techniques for our purposes. Remotely sensed satellite images often view a large scale of land at a time. There are several kinds of satellite images, which of different spatial and spectral resolutions. Landsat-4/5 TM sensor can view ground at 30m resolution, while Landsat-7 ETM Plus has a resolution of 15m in panchromatic waveband. SPOT satellite can provide images with higher resolutions. Those images obtained pre- and post-earthquake can help us greatly in identifying damages of moderate and large-size buildings. In this paper, we bring forward a method to implement quick damages assessment by analyzing both pre- and post-earthquake satellite images. First, those images are geographically registered together with low RMS (Root Mean Square) error. Then, we clip out residential areas by overlaying images with existing vector layers through Geographic Information System (GIS) software. We present a new change detection algorithm to quantitatively identify damages degree. An empirical or semi-empirical model is then established by analyzing the real damage degree and changes of pixel values of the same ground objects. Experimental result shows that there is a good linear relationship between changes of pixel values and ground damages, which proves the potentials of remote sensing in post-quake fast damage assessment. Keywords: Damages Assessment, Earthquake Hazard, Remote Sensing

  15. The effect of urbanization in an arid region: Formation of a perched water table that causes environmental damages

    Science.gov (United States)

    Karnieli, A.; Issar, A.; Wolf, M.

    1984-03-01

    Construction in a new neighborhood in the israeli town of Dimona, situated in an arid region in the south of the country (150 mm average annual rainfall), resulted in a rise in groundwater levels during the subsequent rainy seasons This caused flooding of shelter basements, soil sliding, and sagging which permanently damaged walls and buildings The neighborhood had been built on continental sands and marls blanketed by loess, on a valley slope near a rocky anticlinal dip-slope Subsurface studies, using piezometer holes and groundwater analyses, revealed the presence of sand lenses alternating with plastic marls, which act as seasonal aquifers with perched water tables Groundwaters obtain high SO{4/-2} and Cl- corrosivity through contact with these nonflushed marls of the Neogene valley fill (Hazeva Formation) The reasons for the rising of groundwater were found to be (a) artificial interference with the natural (pre-construction) drainage system—interception of the hillside runoff by building plots, roads, etc, (b) partial denudation of the loess blanket, increasing the local infiltration and the build-up of local, perched water tables, and (c) corrosion of concrete and steel pipelines, as well as foundations, by prolonged contact with corrosive groundwater, resulting in haphazard but massive leakage Guidelines are proposed for an environmental improvement plan, which would include terracing and planting of the watershed above town to increase evapotranspiration, lowering of the water table by pumping, and diverting the water to suburban parks (groves of saltresistant trees), and replacement of steel and cement pipes by a non-corrodable plastic pipe system

  16. Case study: Fixture water use and drinking water quality in a new residential green building.

    Science.gov (United States)

    Salehi, Maryam; Abouali, Mohammad; Wang, Mian; Zhou, Zhi; Nejadhashemi, Amir Pouyan; Mitchell, Jade; Caskey, Stephen; Whelton, Andrew J

    2018-03-01

    Residential plumbing is critical for the health and safety of populations worldwide. A case study was conducted to understand fixture water use, drinking water quality and their possible link, in a newly plumbed residential green building. Water use and water quality were monitored at four in-building locations from September 2015 through December 2015. Once the home was fully inhabited average water stagnation periods were shortest at the 2nd floor hot fixture (90 percentile of 0.6-1.2 h). The maximum water stagnation time was 72.0 h. Bacteria and organic carbon levels increased inside the plumbing system compared to the municipal tap water entering the building. A greater amount of bacteria was detected in hot water samples (6-74,002 gene copy number/mL) compared to cold water (2-597 gene copy number/mL). This suggested that hot water plumbing promoted greater microbial growth. The basement fixture brass needle valve may have caused maximum Zn (5.9 mg/L), Fe (4.1 mg/L), and Pb (23 μg/L) levels compared to other fixture water samples (Zn ≤ 2.1 mg/L, Fe ≤ 0.5 mg/L and Pb ≤ 8 μg/L). At the basement fixture, where the least amount of water use events occurred (cold: 60-105, hot: 21-69 event/month) compared to the other fixtures in the building (cold: 145-856, hot: 326-2230 event/month), greater organic carbon, bacteria, and heavy metal levels were detected. Different fixture use patterns resulted in disparate water quality within a single-family home. The greatest drinking water quality changes were detected at the least frequently used fixture. Copyright © 2017 Elsevier Ltd. All rights reserved.

  17. Laser-induced damage thresholds of gold, silver and their alloys in air and water

    Energy Technology Data Exchange (ETDEWEB)

    Starinskiy, Sergey V.; Shukhov, Yuri G.; Bulgakov, Alexander V., E-mail: bulgakov@itp.nsc.ru

    2017-02-28

    Highlights: • Laser damage thresholds of Ag, Au and Ag-Au alloys in air and water are measured. • Alloy thresholds are lower than those of Ag and Au due to low thermal conductivity. • Laser damage thresholds in water are ∼1.5 times higher than those in air. • Light scattering mechanisms responsible for high thresholds in water are suggested. • Light scattering mechanisms are supported by optical reflectance measurements. - Abstract: The nanosecond-laser-induced damage thresholds of gold, silver and gold-silver alloys of various compositions in air and water have been measured for single-shot irradiation conditions. The experimental results are analyzed theoretically by solving the heat flow equation for the samples irradiated in air and in water taking into account vapor nucleation at the solid-water interface. The damage thresholds of Au-Ag alloys are systematically lower than those for pure metals, both in air and water that is explained by lower thermal conductivities of the alloys. The thresholds measured in air agree well with the calculated melting thresholds for all samples. The damage thresholds in water are found to be considerably higher, by a factor of ∼1.5, than the corresponding thresholds in air. This cannot be explained, in the framework of the used model, neither by the conductive heat transfer to water nor by the vapor pressure effect. Possible reasons for the high damage thresholds in water such as scattering of the incident laser light by the vapor-liquid interface and the critical opalescence in the superheated water are suggested. Optical pump-probe measurements have been performed to study the reflectance dynamics of the surface irradiated in air and water. Comparison of the transient reflectance signal with the calculated nucleation dynamics provides evidence that the both suggested scattering mechanisms are likely to occur during metal ablation in water.

  18. Lessons from the Mexican earthquake 1985: Quantitative evaluation of damage and damage parameters

    International Nuclear Information System (INIS)

    Tiedemann, H.

    1992-01-01

    In Mexico City, all buildings of more than 5 storeys were inspected in order to assess the relative importance of different damage parameters. The general mean damage (MDR) was 32.1%; ranging between 94.13% for 2% g buildings and 1.89% for 10% g buildings. Stiff buildings had much lower MDR's than soft ones. Irregularity and asymmetry increased MDR's significantly. The MDR's of oblong buildings strongly depended on their orientation. Most of the overall damage resulted from failure of non-structural items. The paper presents a detailed account of these findings and the salient lessons to be learned from them. (author). 13 refs, 1 fig., 1 tab

  19. Effect of water availability on tolerance of leaf damage in tall morning glory, Ipomoea purpurea

    Science.gov (United States)

    Atala, Cristian; Gianoli, Ernesto

    2009-03-01

    Resource availability may limit plant tolerance of herbivory. To predict the effect of differential resource availability on plant tolerance, the limiting resource model (LRM) considers which resource limits plant fitness and which resource is mostly affected by herbivore damage. We tested the effect of experimental drought on tolerance of leaf damage in Ipomoea purpurea, which is naturally exposed to both leaf damage and summer drought. To seek mechanistic explanations, we also measured several morphological, allocation and gas exchange traits. In this case, LRM predicts that tolerance would be the same in both water treatments. Plants were assigned to a combination of two water treatments (control and low water) and two damage treatments (50% defoliation and undamaged). Plants showed tolerance of leaf damage, i.e., a similar number of fruits were produced by damaged and undamaged plants, only in control water. Whereas experimental drought affected all plant traits, leaf damage caused plants to show a greater leaf trichome density and reduced shoot biomass, but only in low water. It is suggested that the reduced fitness (number of fruits) of damaged plants in low water was mediated by the differential reduction of shoot biomass, because the number of fruits per shoot biomass was similar in damaged and undamaged plants. Alternative but less likely explanations include the opposing direction of functional responses to drought and defoliation, and resource costs of the damage-induced leaf trichome density. Our results somewhat challenge the LRM predictions, but further research including field experiments is needed to validate some of the preliminary conclusions drawn.

  20. Potential for HEPA filter damage from water spray systems in filter plenums

    Energy Technology Data Exchange (ETDEWEB)

    Bergman, W. [Lawrence Livermore National Lab., CA (United States); Fretthold, J.K. [Rocky Flats Safe Sites of Colorado, Golden, CO (United States); Slawski, J.W. [Department of Energy, Germantown, MD (United States)

    1997-08-01

    The water spray systems in high efficiency particulate air (HEPA) filter plenums that are used in nearly all Department of Energy (DOE) facilities for protection against fire was designed under the assumption that the HEPA filters would not be damaged by the water sprays. The most likely scenario for filter damage involves filter plugging by the water spray, followed by the fan blowing out the filter medium. A number of controlled laboratory tests that were previously conducted in the late 1980s are reviewed in this paper to provide a technical basis for the potential HEPA filter damage by the water spray system in HEPA filter plenums. In addition to the laboratory tests, the scenario for BEPA filter damage during fires has also occurred in the field. A fire in a four-stage, BEPA filter plenum at Rocky Flats in 1980 caused the first three stages of BEPA filters to blow out of their housing and the fourth stage to severely bow. Details of this recently declassified fire are presented in this paper. Although these previous findings suggest serious potential problems exist with the current water spray system in filter plenums, additional studies are required to confirm unequivocally that DOE`s critical facilities are at risk. 22 refs., 15 figs.

  1. MORPHOLOGICAL HIT-OR-MISS TRANSFORM BASED APPROACH FOR BUILDING DAMAGE ESTIMATION FROM VHR AIRBORNE IMAGERY IN 2011 PACIFIC COAST OF TOHOKU EARTHQUAKE AND TSUNAMI

    Directory of Open Access Journals (Sweden)

    C. D. K. Parape

    2012-08-01

    Full Text Available The very high resolution (VHR airborne images offer the opportunity to recognize features such as road, vegetation, buildings and other kind of infrastructures. The advantage of remote sensing and its applications made it possible to extract damaged, undamaged building and vulnerability assessment of wide urban areas due to a natural disaster. In this paper, we focus on an automatic building detection method which is helpful to optimizing, recognizing, rescuing, recovery and management tasks in the event of a disaster. Objective of this study is to develop techniques for tsunami damaged building extraction, based on very high resolution (VHR airborne images acquired before and after the 2011 East coastline of Japan among Tohoku area and to carry out a damage assessment of building and vulnerable area mapping. This paper presents a methodology and results of evaluating damaged buildings detection algorithm using an object recognition task based on Mathematical Morphological (MM operators for Very High Resolution (VHR remotely sensed airborne images. The proposed approach involves several advanced morphological operators among which an adaptive hit-or-miss transform with varying size and shape of the structuring elements. VHR airborne images consisting of pre and post 2011 Pacific coast of Tohoku earthquake and Tsunami site of the Ishinomaki, Miyagi area in Japan were used. The extracted results of building were compared with ground truth data giving 76% and 88% in accuracy before and after the Tsunami event.

  2. Assessment of corrosion and fatigue damage to light water reactor metal containments

    International Nuclear Information System (INIS)

    Sinha, U.P.; Shah, V.N.; Smith, S.K.

    1991-01-01

    This paper presents a generic procedure for estimating aging damage, evaluating structural integrity, and identifying mitigation activities for safe operation of boiling water reactor (BWR) Mark I metal containments and ice-condenser type pressurized water reactor (PWR) cylindrical metal containments. The mechanisms of concern that can cause aging damage to these two types of containments are corrosion and fatigue. Assessment of fatigue damage to bellows is also described. Assessment of corrosion and fatigue damage described in this paper include: containment design features that are relevant to aging assessment, several corrosion and fatigue mechanisms, inspection of corrosion and fatigue damage, and mitigation of damage caused by these mechanisms. In addition, synergistic interaction between corrosion and fatigue is considered. Possible actions for mitigating aging include enhanced inspection methods, maintenance activities based on operating experience, and supplementary surveillance programs. Field experience related to aging of metal containments is reviewed. Finally, conclusions and recommendations are presented

  3. Forecast on Water Locking Damage of Low Permeable Reservoir with Quantum Neural Network

    Science.gov (United States)

    Zhao, Jingyuan; Sun, Yuxue; Feng, Fuping; Zhao, Fulei; Sui, Dianjie; Xu, Jianjun

    2018-01-01

    It is of great importance in oil-gas reservoir protection to timely and correctly forecast the water locking damage, the greatest damage for low permeable reservoir. An analysis is conducted on the production mechanism and various influence factors of water locking damage, based on which a quantum neuron is constructed based on the information processing manner of a biological neuron and the principle of quantum neural algorithm, besides, the quantum neural network model forecasting the water locking of the reservoir is established and related software is also made to forecast the water locking damage of the gas reservoir. This method has overcome the defects of grey correlation analysis that requires evaluation matrix analysis and complicated operation. According to the practice in Longxi Area of Daqing Oilfield, this method is characterized by fast operation, few system parameters and high accuracy rate (the general incidence rate may reach 90%), which can provide reliable support for the protection technique of low permeable reservoir.

  4. Potential Damage to Modern Building Materials from 21st Century Air Pollution

    Directory of Open Access Journals (Sweden)

    Peter Brimblecombe

    2010-01-01

    Full Text Available The evolution of damage to building materials has been estimated for the 21st century, with a particular focus on aluminum, zinc, copper, plastic, paint, and rubber in urban areas. We set idealized air pollution and climates to represent London and Prague across the period 1950–2100. Environmental parameters were used to estimate future recession, corrosion, and loss of properties through published damage or dose-response functions. The 21st century seems to provide a less aggressive environment for stone and metals than recent times. Improvements in air quality are the most relevant drivers for this amelioration. Changes in climate predicted for the 21st century do not alter this picture. On the other hand, polymeric materials, plastic, paint, and rubber might show slightly increased rates of degradation, to some extent the result of enhanced oxidant concentrations, but also the possibility of contributions from more solar radiation.

  5. Predicting the hurricane damage ratio of commercial buildings by claim payout from Hurricane Ike

    OpenAIRE

    J. M. Kim; P. K. Woods; Y. J. Park; T. H. Kim; J. S. Choi; K. Son

    2013-01-01

    The increasing occurrence of natural disaster events and related damages have led to a growing demand for models that predict financial loss. Although considerable research has studied the financial losses related to natural disaster events, and has found significant predictors, there has not yet been a comprehensive study that addresses the relationship among the vulnerabilities, natural disasters, and economic losses of the individual buildings. This study...

  6. Singapore's Aarden City Construction and Green Building Development

    Science.gov (United States)

    Xiong, Chenhui; Chen, Jian

    2018-05-01

    The government of Singapore has a high demand for city construction planning always adhere to the implementation of "garden city " theory. Singapore’s government has been following the "sustainable" of Singapore's requirement and fully embodies the "green building" and "environmental protection"concept. To set the ecological construction and protection of water resources as the total target, minimize damage to the environment of economic development, make Singapore a pioneer "green building". In recent years, the Chinese government is promoting green building but harvest little, in this case, for the development of "green building", China can draw lessons from Singapore's experience.

  7. Mental models of a water management system in a green building.

    Science.gov (United States)

    Kalantzis, Anastasia; Thatcher, Andrew; Sheridan, Craig

    2016-11-01

    This intergroup case study compared users' mental models with an expert design model of a water management system in a green building. The system incorporates a constructed wetland component and a rainwater collection pond that together recycle water for re-use in the building and its surroundings. The sample consisted of five building occupants and the cleaner (6 users) and two experts who were involved with the design of the water management system. Users' mental model descriptions and the experts' design model were derived from in-depth interviews combined with self-constructed (and verified) diagrams. Findings from the study suggest that there is considerable variability in the user mental models that could impact the efficient functioning of the water management system. Recommendations for improvements are discussed. Copyright © 2016 Elsevier Ltd. All rights reserved.

  8. Damage mechanisms of pathogenic bacteria in drinking water ...

    African Journals Online (AJOL)

    This study aimed at elucidating the inactivation mechanisms of pathogenic bacteria in drinking water during chlorine and solar disinfection using a simple plating method. The well-known bacterial model Escherichia coli was used as pathogenic bacteria for the experiments. The damage mechanisms of E. coli were ...

  9. Water sorption kinetics of damaged beans: GAB model

    Directory of Open Access Journals (Sweden)

    Fernanda M. Baptestini

    Full Text Available ABSTRACT The objective of this study was to model the water sorption kinetics of damaged beans. Grains with initial moisture content of 53.85%, dry basis (d.b., were used. One portion of the grains was used to obtain desorption isotherms, while the other was subjected to drying until the moisture content of 5.26% (d.b., so that it was subjected to the adsorption. For the induction of damage, a Stein Breakage Tester was used. To obtain the equilibrium moisture content, grains were placed in a climatic chamber at 20, 30, 40 and 50 ± 1 °C combined with relative humidity of 30, 40, 50, 70 and 90 ± 3%. The GAB model fitted well to the equilibrium moisture experimental data of damaged grains and control. With increasing temperature, the monolayer moisture contents decreased in adsorption and desorption processes, ranging from 9.84 to 5.10% d.b. The lower moisture content in the monolayer in damaged grains indicates that lower moisture content is necessary to ensure their conservation.

  10. Fire flow water consumption in sprinklered and unsprinklered buildings an assessment of community impacts

    CERN Document Server

    Code Consultants, Inc.

    2012-01-01

    Fire Flow Water Consumption in Sprinklered and Unsprinklered Buildings offers a detailed analysis for calculating the fire water demand required in buildings with existing and non-existant sprinkler systems. The installation of automatic sprinkler systems can significantly reduce the amount of water needed during a fire, but it requires water for commissioning, inspection, testing, and maintenance (CITM). This book provides an estimate of fire water used under both fire conditions, including CITM, to allow communities to develop fire water fees for both sprinklered and unsprinklered buildings that are proportional to the anticipated fire water usage. The types of buildings analyzed include residential (family dwellings as well as those up to four stories in height), business, assembly, institutional, mercantile, and storage facilities. Water volume was studied using guidelines from the International Code Council, the National Fire Protection Association, and the Insurance Services Office. Fire Flow Water Cons...

  11. Water and erosion damage to coastal structures: South Carolina Coast, Hurricane Hugo, 1989

    OpenAIRE

    Wang, Hsiang

    1990-01-01

    Hurricane Hugo hit U.S. Mainland on September 21, 1989 just north of Charleston, South Carolina. It was billed as the most costly hurricane on record. The loss on the mainland alone exceeded 7 billion dollars, more than 15,000 homes were destroyed and the loss of lives exceeded forty. This article documents one aspect of the multi-destructions caused by the hurricane - the water and erosion damage on water front or near water front properties. A general damage surve...

  12. Laser-induced damage thresholds of gold, silver and their alloys in air and water

    Science.gov (United States)

    Starinskiy, Sergey V.; Shukhov, Yuri G.; Bulgakov, Alexander V.

    2017-02-01

    The nanosecond-laser-induced damage thresholds of gold, silver and gold-silver alloys of various compositions in air and water have been measured for single-shot irradiation conditions. The experimental results are analyzed theoretically by solving the heat flow equation for the samples irradiated in air and in water taking into account vapor nucleation at the solid-water interface. The damage thresholds of Au-Ag alloys are systematically lower than those for pure metals, both in air and water that is explained by lower thermal conductivities of the alloys. The thresholds measured in air agree well with the calculated melting thresholds for all samples. The damage thresholds in water are found to be considerably higher, by a factor of ∼1.5, than the corresponding thresholds in air. This cannot be explained, in the framework of the used model, neither by the conductive heat transfer to water nor by the vapor pressure effect. Possible reasons for the high damage thresholds in water such as scattering of the incident laser light by the vapor-liquid interface and the critical opalescence in the superheated water are suggested. Optical pump-probe measurements have been performed to study the reflectance dynamics of the surface irradiated in air and water. Comparison of the transient reflectance signal with the calculated nucleation dynamics provides evidence that the both suggested scattering mechanisms are likely to occur during metal ablation in water.

  13. Evaluating the Life Cycle Environmental Benefits and Trade-Offs of Water Reuse Systems for Net-Zero Buildings.

    Science.gov (United States)

    Hasik, Vaclav; Anderson, Naomi E; Collinge, William O; Thiel, Cassandra L; Khanna, Vikas; Wirick, Jason; Piacentini, Richard; Landis, Amy E; Bilec, Melissa M

    2017-02-07

    Aging water infrastructure and increased water scarcity have resulted in higher interest in water reuse and decentralization. Rating systems for high-performance buildings implicitly promote the use of building-scale, decentralized water supply and treatment technologies. It is important to recognize the potential benefits and trade-offs of decentralized and centralized water systems in the context of high-performance buildings. For this reason and to fill a gap in the current literature, we completed a life cycle assessment (LCA) of the decentralized water system of a high-performance, net-zero energy, net-zero water building (NZB) that received multiple green building certifications and compared the results with two modeled buildings (conventional and water efficient) using centralized water systems. We investigated the NZB's impacts over varying lifetimes, conducted a break-even analysis, and included Monte Carlo uncertainty analysis. The results show that, although the NZB performs better in most categories than the conventional building, the water efficient building generally outperforms the NZB. The lifetime of the NZB, septic tank aeration, and use of solar energy have been found to be important factors in the NZB's impacts. While these findings are specific to the case study building, location, and treatment technologies, the framework for comparison of water and wastewater impacts of various buildings can be applied during building design to aid decision making. As we design and operate high-performance buildings, the potential trade-offs of advanced decentralized water treatment systems should be considered.

  14. Survey, Hbim and Conservation Plan of a Monumental Building Damaged by Earthquake

    Science.gov (United States)

    Oreni, D.; Brumana, R.; Della Torre, S.; Banfi, F.

    2017-05-01

    Surveying a monumental building damaged by the earthquake means to analyse its geometries, the structural elements, the connection still exist between the different parts, in order to define its state of conservation, to make structural analysis and to plan a proper project of restoration, consolidation, seismic improvement or addition of new elements. The survey of structural geometry represents the first necessary moment of building' knowledge investigation, to be performed after the securing of the building by the Firefighters or Civil Protection. How and by which instruments the geometric analysis are conducted depends on many factors, not always exclusively on the will of the experts involved in the restoration project, but more often dictated by political, technical, social or economic needs. The accurate geometrical survey is referred as fundamental operation even by national Directive for evaluation and earthquake risk reduction of cultural heritage (GU n. 24 - 29/01/2008 and 2011 updates), which defines guidelines for preventive interventions on built heritage in order to make the structures less vulnerable in case of earthquake. Nowadays, the wide use of tools and accurate surveying techniques makes it possible to achieve an adequate level of accuracy of information related to the buildings, overcoming the difficulties due to accessibility of the damaged structures. The geometrical survey of the Basilica of Santa Maria di Collemaggio in L'Aquila, was made by Politecnico di Milano starting from 2013, within the project "Ripartire da Collemaggio" (http://www.ungiornoacollemaggio.it/content/2027), financed by Eniservizi. The basilica, an important symbol for the community of L'Aquila, was gravely damaged by the earthquake of 6th April 2009. The objective of Eni was to turn the restoration of the building in a re-birth moment for all the community. The knowledge step was aimed to plan a restoration project able of returning the basilica to a safe and full use

  15. Recorded motions of the 6 April 2009 Mw 6.3 L'Aquila, Italy, earthquake and implications for building structural damage: Overview

    Science.gov (United States)

    Celebi, M.; Bazzurro, P.; Chiaraluce, L.; Clemente, P.; Decanini, L.; Desortis, A.; Ellsworth, W.; Gorini, A.; Kalkan, E.; Marcucci, S.; Milana, G.; Mollaioli, F.; Olivieri, M.; Paolucci, R.; Rinaldis, D.; Rovelli, A.; Sabetta, F.; Stephens, C.

    2010-01-01

    The normal-faulting earthquake of 6 April 2009 in the Abruzzo Region of central Italy caused heavy losses of life and substantial damage to centuriesold buildings of significant cultural importance and to modern reinforcedconcrete- framed buildings with hollow masonry infill walls. Although structural deficiencies were significant and widespread, the study of the characteristics of strong motion data from the heavily affected area indicated that the short duration of strong shaking may have spared many more damaged buildings from collapsing. It is recognized that, with this caveat of shortduration shaking, the infill walls may have played a very important role in preventing further deterioration or collapse of many buildings. It is concluded that better new or retrofit construction practices that include reinforcedconcrete shear walls may prove helpful in reducing risks in such seismic areas of Italy, other Mediterranean countries, and even in United States, where there are large inventories of deficient structures. ?? 2010, Earthquake Engineering Research Institute.

  16. Development of damage probability matrices based on Greek earthquake damage data

    Science.gov (United States)

    Eleftheriadou, Anastasia K.; Karabinis, Athanasios I.

    2011-03-01

    A comprehensive study is presented for empirical seismic vulnerability assessment of typical structural types, representative of the building stock of Southern Europe, based on a large set of damage statistics. The observational database was obtained from post-earthquake surveys carried out in the area struck by the September 7, 1999 Athens earthquake. After analysis of the collected observational data, a unified damage database has been created which comprises 180,945 damaged buildings from/after the near-field area of the earthquake. The damaged buildings are classified in specific structural types, according to the materials, seismic codes and construction techniques in Southern Europe. The seismic demand is described in terms of both the regional macroseismic intensity and the ratio α g/ a o, where α g is the maximum peak ground acceleration (PGA) of the earthquake event and a o is the unique value PGA that characterizes each municipality shown on the Greek hazard map. The relative and cumulative frequencies of the different damage states for each structural type and each intensity level are computed in terms of damage ratio. Damage probability matrices (DPMs) and vulnerability curves are obtained for specific structural types. A comparison analysis is fulfilled between the produced and the existing vulnerability models.

  17. Hazard-to-Risk: High-Performance Computing Simulations of Large Earthquake Ground Motions and Building Damage in the Near-Fault Region

    Science.gov (United States)

    Miah, M.; Rodgers, A. J.; McCallen, D.; Petersson, N. A.; Pitarka, A.

    2017-12-01

    We are running high-performance computing (HPC) simulations of ground motions for large (magnitude, M=6.5-7.0) earthquakes in the near-fault region (steel moment frame buildings throughout the near-fault domain. For ground motions, we are using SW4, a fourth order summation-by-parts finite difference time-domain code running on 10,000-100,000's of cores. Earthquake ruptures are generated using the Graves and Pitarka (2017) method. We validated ground motion intensity measurements against Ground Motion Prediction Equations. We considered two events (M=6.5 and 7.0) for vertical strike-slip ruptures with three-dimensional (3D) basin structures, including stochastic heterogeneity. We have also considered M7.0 scenarios for a Hayward Fault rupture scenario which effects the San Francisco Bay Area and northern California using both 1D and 3D earth structure. Dynamic, inelastic response of canonical buildings is computed with the NEVADA, a nonlinear, finite-deformation finite element code. Canonical buildings include 3-, 9-, 20- and 40-story steel moment frame buildings. Damage potential is tracked by the peak inter-story drift (PID) ratio, which measures the maximum displacement between adjacent floors of the building and is strongly correlated with damage. PID ratios greater 1.0 generally indicate non-linear response and permanent deformation of the structure. We also track roof displacement to identify permanent deformation. PID (damage) for a given earthquake scenario (M, slip distribution, hypocenter) is spatially mapped throughout the SW4 domain with 1-2 km resolution. Results show that in the near fault region building damage is correlated with peak ground velocity (PGV), while farther away (> 20 km) it is better correlated with peak ground acceleration (PGA). We also show how simulated ground motions have peaks in the response spectra that shift to longer periods for larger magnitude events and for locations of forward directivity, as has been reported by

  18. Building damage assessment after the earthquake in Haiti using two post-event satellite stereo imagery and DSMs

    DEFF Research Database (Denmark)

    Reinartz, Peter; Tian, Jiaojiao; Nielsen, Allan Aasbjerg

    2013-01-01

    In this paper, a novel disaster building damage monitoring method is presented. This method combines the multispectral imagery and DSMs from stereo matching to obtain three kinds of changes. The proposed method contains three basic steps. The first step is to segment the panchromatic images to ge...... (mainly temporary residential area, etc. tents). In the last step, a region based grey level co-occurrence matrix texture measurement is used to refine the third change class. The method is applied to building change detection after the Haiti earthquake....

  19. Air Emissions Damages from Municipal Drinking Water Treatment Under Current and Proposed Regulatory Standards.

    Science.gov (United States)

    Gingerich, Daniel B; Mauter, Meagan S

    2017-09-19

    Water treatment processes present intersectoral and cross-media risk trade-offs that are not presently considered in Safe Drinking Water Act regulatory analyses. This paper develops a method for assessing the air emission implications of common municipal water treatment processes used to comply with recently promulgated and proposed regulatory standards, including concentration limits for, lead and copper, disinfection byproducts, chromium(VI), strontium, and PFOA/PFOS. Life-cycle models of electricity and chemical consumption for individual drinking water unit processes are used to estimate embedded NO x , SO 2 , PM 2.5 , and CO 2 emissions on a cubic meter basis. We estimate air emission damages from currently installed treatment processes at U.S. drinking water facilities to be on the order of $500 million USD annually. Fully complying with six promulgated and proposed rules would increase baseline air emission damages by approximately 50%, with three-quarters of these damages originating from chemical manufacturing. Despite the magnitude of these air emission damages, the net benefit of currently implemented rules remains positive. For some proposed rules, however, the promise of net benefits remains contingent on technology choice.

  20. Why Buildings Fail: Are We Learning From Our Mistakes?

    Directory of Open Access Journals (Sweden)

    M. Kevin Parfitt

    2012-09-01

    Full Text Available Most building professionals have investigated or performed remedial designs for at least one architectural or engineering system failure during their careers. Other practitioners, especially those who work for forensic consultants or firms specializing in disaster response and repair, are more familiar with the variety and extent of building failures as they assist their clients in restoring damaged or deficient buildings. The advent of social medial and twenty-four-hour news channels along with the general ease of finding more examples of failures in the Internet have made us realize that building failures in the broad sense are much more common than we may have realized.Relatively recent events leading to building failures such as the Christchurch, New Zealand earthquakes, the roof/parking deck of the Algo Centre mall in the northern Ontario, Canada city of Elliot Lake and the Indiana State Fairground stage collapse in the US are just a few reminders that much more work needs to be done on a variety of fronts to prevent building failures from a life safety standpoint. The need is compounded by economic concerns from what would be considered more mundane or common failures. Inspections by the author after Hurricane Katrina revealed a huge number of failures associated rain water alone as roofs, windows, flashing, mechanical penetrations etc. failed leading to interior water penetration often resulting in more damage from damp conditions and mold propagation than outright structural collapses.

  1. SURVEY, HBIM AND CONSERVATION PLAN OF A MONUMENTAL BUILDING DAMAGED BY EARTHQUAKE

    Directory of Open Access Journals (Sweden)

    D. Oreni

    2017-05-01

    Full Text Available Surveying a monumental building damaged by the earthquake means to analyse its geometries, the structural elements, the connection still exist between the different parts, in order to define its state of conservation, to make structural analysis and to plan a proper project of restoration, consolidation, seismic improvement or addition of new elements. The survey of structural geometry represents the first necessary moment of building’ knowledge investigation, to be performed after the securing of the building by the Firefighters or Civil Protection. How and by which instruments the geometric analysis are conducted depends on many factors, not always exclusively on the will of the experts involved in the restoration project, but more often dictated by political, technical, social or economic needs. The accurate geometrical survey is referred as fundamental operation even by national Directive for evaluation and earthquake risk reduction of cultural heritage (GU n. 24 – 29/01/2008 and 2011 updates, which defines guidelines for preventive interventions on built heritage in order to make the structures less vulnerable in case of earthquake. Nowadays, the wide use of tools and accurate surveying techniques makes it possible to achieve an adequate level of accuracy of information related to the buildings, overcoming the difficulties due to accessibility of the damaged structures. The geometrical survey of the Basilica of Santa Maria di Collemaggio in L'Aquila, was made by Politecnico di Milano starting from 2013, within the project "Ripartire da Collemaggio" (http://www.ungiornoacollemaggio.it/content/2027, financed by Eniservizi. The basilica, an important symbol for the community of L'Aquila, was gravely damaged by the earthquake of 6th April 2009. The objective of Eni was to turn the restoration of the building in a re-birth moment for all the community. The knowledge step was aimed to plan a restoration project able of returning the basilica

  2. Allegheny County Municipal Building Energy and Water Use

    Data.gov (United States)

    Allegheny County / City of Pittsburgh / Western PA Regional Data Center — This dataset contains energy and water use information from 2010 to 2014 for 144 County-operated buildings. Metrics include: kBtu (thousand British thermal units),...

  3. How to build a small ferro-cement water tank: technical guide

    CSIR Research Space (South Africa)

    Sadzik, P

    1988-05-01

    Full Text Available This guide will assist on how to build a small water tank which can be used to store spring water, rainwater or water pumped from a stream or dam. Small water tanks can be constructed from many different materials such as corrugated iron, bricks...

  4. Sensitivity analysis of water consumption in an office building

    Science.gov (United States)

    Suchacek, Tomas; Tuhovcak, Ladislav; Rucka, Jan

    2018-02-01

    This article deals with sensitivity analysis of real water consumption in an office building. During a long-term real study, reducing of pressure in its water connection was simulated. A sensitivity analysis of uneven water demand was conducted during working time at various provided pressures and at various time step duration. Correlations between maximal coefficients of water demand variation during working time and provided pressure were suggested. The influence of provided pressure in the water connection on mean coefficients of water demand variation was pointed out, altogether for working hours of all days and separately for days with identical working hours.

  5. Radiation damage to uracil and water by proton and electron impact

    International Nuclear Information System (INIS)

    Scheier, P.; Hanel, G.; Denifl, S; Gstir, B.; Maerk, T.D.; Farizon, B.; Farizon, M.; Coupier, B.

    2002-01-01

    Full text: The inelastic interaction of protons (in the energy range from 20 keV to 150 keV) and electrons (from thermal energies up to 20 eV) with water and uracil, the latter a building block of the RNA has been studied in two laboratories with specially designed experimental setups. These measurements are motivated from a present lack of understanding how on a molecular level damage to living cells and organisms is caused. A unique way of simultaneous detection of the product ions after swift proton (or hydrogen) impact and the analysis of the charge state of the projectile after the collision allows to distinguish between direct ionization (e.g., projectile remains a proton) and electron capture events (e.g., proton becomes neutralized). The latter process turns out to be more destructive, i.e. leads to a higher yield of fragmentation. For electrons both the formation of positively and negatively charged ions has been investigated. We discovered that already thermal electrons lead with a rather large cross section to a dissociation of the uracil molecule producing an anion and a fast hydrogen radical. (author)

  6. DEPENDENCE OF DISTRIBUTION FUNCTION OF COMMERCIAL DAMAGES DUE TO POSSIBLE EARTHQUAKES ON THE CLASS OF SEISMIC RESISTANCE OF A BUILDING

    OpenAIRE

    Hanzada R. Zajnulabidova; Alexander M. Uzdin; Tatiana M. Chirkst

    2017-01-01

    Abstract. Objectives To determine the damage probability of earthquakes of different intensities on the example of a real projected railway station building having a framework design scheme based on the density function of damage distribution. Methods Uncertainty, always existing in nature, invalidates a deterministic approach to the assessment of territorial seismic hazards and, consequently, seismic risk. In this case, seismic risk assessment can be carried out on a probabilistic basis. Thu...

  7. The development of damage identification methods for buildings with image recognition and machine learning techniques utilizing aerial photographs of the 2016 Kumamoto earthquake

    Science.gov (United States)

    Shohei, N.; Nakamura, H.; Fujiwara, H.; Naoichi, M.; Hiromitsu, T.

    2017-12-01

    It is important to get schematic information of the damage situation immediately after the earthquake utilizing photographs shot from an airplane in terms of the investigation and the decision-making for authorities. In case of the 2016 Kumamoto earthquake, we have acquired more than 1,800 orthographic projection photographs adjacent to damaged areas. These photos have taken between April 16th and 19th by airplanes, then we have distinguished damages of all buildings with 4 levels, and organized as approximately 296,000 GIS data corresponding to the fundamental Geospatial data published by Geospatial Information Authority of Japan. These data have organized by effort of hundreds of engineers. However, it is not considered practical for more extensive disasters like the Nankai Trough earthquake by only human powers. So, we have been developing the automatic damage identification method utilizing image recognition and machine learning techniques. First, we have extracted training data of more than 10,000 buildings which have equally damage levels divided in 4 grades. With these training data, we have been raster scanning in each scanning ranges of entire images, then clipping patch images which represents damage levels each. By utilizing these patch images, we have been developing discriminant models by two ways. One is a model using the Support Vector Machine (SVM). First, extract a feature quantity of each patch images. Then, with these vector values, calculate the histogram density as a method of Bag of Visual Words (BoVW), then classify borders with each damage grades by SVM. The other one is a model using the multi-layered Neural Network. First, design a multi-layered Neural Network. Second, input patch images and damage levels based on a visual judgement, and then, optimize learning parameters with error backpropagation method. By use of both discriminant models, we are going to discriminate damage levels in each patches, then create the image that shows

  8. Numerical Simulation of the Effects of Water Surface in Building Environment

    Science.gov (United States)

    Li, Guangyao; Pan, Yuqing; Yang, Li

    2018-03-01

    Water body could affect the thermal environment and airflow field in the building districts, because of its special thermal characteristics, evaporation and flat surface. The thermal influence of water body in Tongji University Jiading Campus front area was evaluated. First, a suitable evaporation model was selected and then was applied to calculate the boundary conditions of the water surface in the Fluent software. Next, the computational fluid dynamics (CFD) simulations were conducted on the models both with and without water, following the CFD practices guidelines. Finally, the outputs of the two simulations were compared with each other. Results showed that the effect of evaporative cooling from water surface strongly depends on the wind direction and temperature decrease was about 2∼5°C. The relative humidity within the enclosing area was affected by both the building arrangement and surrounding water. An increase of about 0.1∼0.2m/s of wind speed induced by the water evaporation was observed in the open space.

  9. Multi-Directional Seismic Assessment of Historical Masonry Buildings by Means of Macro-Element Modelling: Application to a Building Damaged during the L’Aquila Earthquake (Italy

    Directory of Open Access Journals (Sweden)

    Francesco Cannizzaro

    2017-11-01

    Full Text Available The experience of the recent earthquakes in Italy caused a shocking impact in terms of loss of human life and damage in buildings. In particular, when it comes to ancient constructions, their cultural and historical value overlaps with the economic and social one. Among the historical structures, churches have been the object of several studies which identified the main characteristics of the seismic response and the most probable collapse mechanisms. More rarely, academic studies have been devoted to ancient palaces, since they often exhibit irregular and complicated arrangement of the resisting elements, which makes their response very difficult to predict. In this paper, a palace located in L’Aquila, severely damaged by the seismic event of 2009 is the object of an accurate study. A historical reconstruction of the past strengthening interventions as well as a detailed geometric relief is performed to implement detailed numerical models of the structure. Both global and local models are considered and static nonlinear analyses are performed considering the influence of the input direction on the seismic vulnerability of the building. The damage pattern predicted by the numerical models is compared with that observed after the earthquake. The seismic vulnerability assessments are performed in terms of ultimate peak ground acceleration (PGA using capacity curves and the Italian code spectrum. The results are compared in terms of ultimate ductility demand evaluated performing nonlinear dynamic analyses considering the actual registered seismic input of L’Aquila earthquake.

  10. Damage and recovery of historic buildings: The experience of L’Aquila

    International Nuclear Information System (INIS)

    Modena, Claudio; Valluzzi, Maria Rosa; Da Porto, Franca; Munari, Marco

    2015-01-01

    Problems range from the same definition and choice of the “conventional” safety level, to the methodologies that can be used to perform reliable structural analyses and safety verifications (as modern ones are frequently not suitable for the construction under consideration) and to the selection, design and execution of appropriate materials and interventions techniques aimed to repair and strengthen the built heritage while preserving its cultural, historic, artistic values. The earthquake that struck the Abruzzo region on 6. April 2009 at 3:32 a.m., had its epicentre in the capital of the region, L’Aquila, and seriously affected a wide area around the city, where many historic towns and villages are found. Lessons learned from this event gave relevant contributions to develop specific tools, to appropriately tackle the above mentioned problems, available to practitioner engineers and architects: methodology to intervene on complex and connected buildings in the historic centres, definition of adequate materials and techniques to intervene on the damaged buildings, codes and codes of practice specific for historic constructions. A short review of all the mentioned aspects is presented in the paper, making specific reference to research activities, practical applications and to the recent evolution of codes and guidelines [it

  11. Evidence on dynamic effects in the water content – water potential relation of building materials

    DEFF Research Database (Denmark)

    Scheffler, Gregor Albrecht; Plagge, Rudolf

    2008-01-01

    static and dynamic moisture storage data and the more pronounced was the corresponding dynamic hysteresis. The paper thus provides clear experimental evidence on dynamic effects in the water content – water potential relation of building materials. By that, data published by previous authors as Topp et......Hygrothermal simulation has become a widely applied tool for the design and assessment of building structures under possible indoor and outdoor climatic conditions. One of the most important prerequisites of such simulations is reliable material data. Different approaches exist here to derive...... the required material functions, i.e. the moisture storage characteristic and the liquid water conductivity, from measured basic properties. The current state of the art in material modelling as well as the corresponding transport theory implies that the moisture transport function is unique...

  12. Responsibility for drinking water; Verantwortung fuer Trinkwasser

    Energy Technology Data Exchange (ETDEWEB)

    Lein, Peter [Ingenieurbuero Dipl.-Ing. Peter Lein, Berlin (Germany)

    2008-03-15

    Planners of drinking water supply systems, implementing sanitary companies as well as building owners probably can be made liable, if the user of drinking water supply systems suffer health damages by drinking water hygienic problems. The germinating of the drinking water with legionella often is the consequence of a not professional start-up of a plant immediately after completion.

  13. Using Solar Hot Water to Address Piping Heat Losses in Multifamily Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Springer, David [Alliance for Residential Building Innovation, Davis, CA (United States); Seitzler, Matt [Alliance for Residential Building Innovation, Davis, CA (United States); Backman, Christine [Alliance for Residential Building Innovation, Davis, CA (United States); Weitzel, Elizabeth [Alliance for Residential Building Innovation, Davis, CA (United States)

    2015-10-01

    Solar thermal water heating is most cost effective when applied to multifamily buildings and some states offer incentives or other inducements to install them. However, typical solar water heating designs do not allow the solar generated heat to be applied to recirculation losses, only to reduce the amount of gas or electric energy needed for hot water that is delivered to the fixtures. For good reasons, hot water that is recirculated through the building is returned to the water heater, not to the solar storage tank. The project described in this report investigated the effectiveness of using automatic valves to divert water that is normally returned through the recirculation piping to the gas or electric water heater instead to the solar storage tank. The valves can be controlled so that the flow is only diverted when the returning water is cooler than the water in the solar storage tank.

  14. Detection device for pipeway water leakage in building

    International Nuclear Information System (INIS)

    Hanawa, Jun.

    1988-01-01

    Purpose: To rapidly detect pipeway leakage at predetermined areas over a wide range in a building. Constitution: If flooding should occur in a power plant building and left as it is, emergency core cooling system, as well as auxiliary equipments and electrical equipments of the system are flooded to make the safety shutdown of the plant impossible. The present invention copes with such a risk. That is, an inlet flow meter and as exit flow meter are disposed to the inlet and the exit of pipeways disposed in a predetermined region in the building and a flow rate difference detector between them is disposed. In this way, pipeway leakage is detected by detecting the flow rate difference between the inlet flow rate and the exit flow rate of the pipeway in the predetermined region. According to the present invention, if a pipeway in a predetermined region is raptured to cause water leakage, the pipeway leakage can rapidly be detected depending on the flow rate difference between the inlet flow rate and the exit flow rate. Further, the water leakage over the entire the predetermined region can be detected rapidly as compared with the conventional case of detecting the leakage at a restricted portion where the leakage detector is disposed. (Kamimura, M.)

  15. Methods of measurement and evaluation of natural radionuclide contents in buildings, at building sites, and in building materials and water

    International Nuclear Information System (INIS)

    1998-01-01

    The recommendations should serve as guidelines for specifying the scope of measurement and ways of evaluating the measuring results when satisfying the relevant requirements laid down by the Czech Atomic Act (Act No. 18/1997) and Decree No. 184/1997 in the field of natural radiation sources occurring in the environment without deliberate use. The document consists of the following sections: Methodology for the measurement and assessment of natural exposure of persons in dwelling rooms of buildings; Methodology of determination of the radon risk of building sites; Principles of systematic measurement and evaluation of natural radionuclide contents of building materials; and Principles of systematic measurement and evaluation of natural radionuclide contents of supplied water. (P.A.)

  16. Technology data characterizing water heating in commercial buildings: Application to end-use forecasting

    Energy Technology Data Exchange (ETDEWEB)

    Sezgen, O.; Koomey, J.G.

    1995-12-01

    Commercial-sector conservation analyses have traditionally focused on lighting and space conditioning because of their relatively-large shares of electricity and fuel consumption in commercial buildings. In this report we focus on water heating, which is one of the neglected end uses in the commercial sector. The share of the water-heating end use in commercial-sector electricity consumption is 3%, which corresponds to 0.3 quadrillion Btu (quads) of primary energy consumption. Water heating accounts for 15% of commercial-sector fuel use, which corresponds to 1.6 quads of primary energy consumption. Although smaller in absolute size than the savings associated with lighting and space conditioning, the potential cost-effective energy savings from water heaters are large enough in percentage terms to warrant closer attention. In addition, water heating is much more important in particular building types than in the commercial sector as a whole. Fuel consumption for water heating is highest in lodging establishments, hospitals, and restaurants (0.27, 0.22, and 0.19 quads, respectively); water heating`s share of fuel consumption for these building types is 35%, 18% and 32%, respectively. At the Lawrence Berkeley National Laboratory, we have developed and refined a base-year data set characterizing water heating technologies in commercial buildings as well as a modeling framework. We present the data and modeling framework in this report. The present commercial floorstock is characterized in terms of water heating requirements and technology saturations. Cost-efficiency data for water heating technologies are also developed. These data are intended to support models used for forecasting energy use of water heating in the commercial sector.

  17. Evaluating the potential of improving residential water balance at building scale.

    Science.gov (United States)

    Agudelo-Vera, Claudia M; Keesman, Karel J; Mels, Adriaan R; Rijnaarts, Huub H M

    2013-12-15

    Earlier results indicated that, for an average household, self-sufficiency in water supply can be achieved by following the Urban harvest Approach (UHA), in a combination of demand minimization, cascading and multi-sourcing. To achieve these results, it was assumed that all available local resources can be harvested. In reality, however, temporal, spatial and location-bound factors pose limitations to this harvest and, thus, to self-sufficiency. This article investigates potential spatial and temporal limitations to harvest local water resources at building level for the Netherlands, with a focus on indoor demand. Two building types were studied, a free standing house (one four-people household) and a mid-rise apartment flat (28 two-person households). To be able to model yearly water balances, daily patterns considering household occupancy and presence of water using appliances were defined per building type. Three strategies were defined. The strategies include demand minimization, light grey water (LGW) recycling, and rainwater harvesting (multi-sourcing). Recycling and multi-sourcing cater for toilet flushing and laundry machine. Results showed that water saving devices may reduce 30% of the conventional demand. Recycling of LGW can supply 100% of second quality water (DQ2) which represents 36% of the conventional demand or up to 20% of the minimized demand. Rainwater harvesting may supply approximately 80% of the minimized demand in case of the apartment flat and 60% in case of the free standing house. To harvest these potentials, different system specifications, related to the household type, are required. Two constraints to recycle and multi-source were identified, namely i) limitations in the grey water production and available rainfall; and ii) the potential to harvest water as determined by the temporal pattern in water availability, water use, and storage and treatment capacities. Copyright © 2013 Elsevier Ltd. All rights reserved.

  18. Building Effective Water Governance in the Asian Highlands | CRDI ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    Building Effective Water Governance in the Asian Highlands ... This project is funded through IDRC's Adaptation Research Initiative in Asia (ARI-Asia) ... Kunming Institute of Botany, Chinese Academy of Sciences as represented by Sun Hang.

  19. Differential Allergy Induction by Molds Found in Water-Damaged Homes

    Science.gov (United States)

    Abstract: We compared the allergy induction potential of high concentration molds found in water-damaged homes and molds found more universally to house dust mite (HDM) in our mouse allergy/asthma model. Female BALB/c mice received 1 or 4 exposures by intratracheal aspiration of ...

  20. Structural health and dynamic behavior of residential buildings: field challenges in the rehab of damaged reinforced concrete

    Directory of Open Access Journals (Sweden)

    Chalhoub M. S.

    2014-01-01

    Full Text Available Reinforced concrete buildings require special consideration under dynamic excitations due to their anisotropic material properties. Strain compatibility equations are used in concrete analysis and design with assumptions about the stress and strain field across member section and member length. However, these assumptions fall short of describing real life behavior when concrete elements deteriorate, age or undergo cyclic loading. This paper addresses the structural health of reinforced concrete buildings and proposes an analytical model to account for concrete damage through loss of bond. The proposed model relates steel loading that causes bond distress to design parameters such as development length and bar properties, and therefore could be complemented by field measurement. The paper proposes a diagnosis method and discusses the sustainability of the structure by assisting in a simplistic decision rule as to whether to perform minor fixes, major rehabilitation, or disposal. Emphasis is placed on the difference between reversible and irreversible effects of cyclic loading on structural behaviour, and draws a distinction between damage to the girder and damage to the column in the overall structural system. The model is compared to empirical results to address field challenges faced when the structure is subjected to severe conditions in its ambient environment, or to unusual loading. Deterioration in concrete causes alteration in its composite behavior with the reinforcing steel. This affects the fundamental period of the structure, and its response to seismic loading.

  1. Flood damage estimation of companies: A comparison of Stage-Damage-Functions and Random Forests

    Science.gov (United States)

    Sieg, Tobias; Kreibich, Heidi; Vogel, Kristin; Merz, Bruno

    2017-04-01

    The development of appropriate flood damage models plays an important role not only for the damage assessment after an event but also to develop adaptation and risk mitigation strategies. So called Stage-Damage-Functions (SDFs) are often applied as a standard approach to estimate flood damage. These functions assign a certain damage to the water depth depending on the use or other characteristics of the exposed objects. Recent studies apply machine learning algorithms like Random Forests (RFs) to model flood damage. These algorithms usually consider more influencing variables and promise to depict a more detailed insight into the damage processes. In addition they provide an inherent validation scheme. Our study focuses on direct, tangible damage of single companies. The objective is to model and validate the flood damage suffered by single companies with SDFs and RFs. The data sets used are taken from two surveys conducted after the floods in the Elbe and Danube catchments in the years 2002 and 2013 in Germany. Damage to buildings (n = 430), equipment (n = 651) as well as goods and stock (n = 530) are taken into account. The model outputs are validated via a comparison with the actual flood damage acquired by the surveys and subsequently compared with each other. This study investigates the gain in model performance with the use of additional data and the advantages and disadvantages of the RFs compared to SDFs. RFs show an increase in model performance with an increasing amount of data records over a comparatively large range, while the model performance of the SDFs is already saturated for a small set of records. In addition, the RFs are able to identify damage influencing variables, which improves the understanding of damage processes. Hence, RFs can slightly improve flood damage predictions and provide additional insight into the underlying mechanisms compared to SDFs.

  2. Prediction of the extent of formation damage caused by water injection

    Energy Technology Data Exchange (ETDEWEB)

    Al-Homadhi, Emad S. [King Saud Univ., Riyadh (Saudi Arabia). Petroleum Engineering Dept.

    2013-06-15

    As a general practice water is injected along the O/W contact to maintain reservoir pressure during production. Down hole analysis of the injected water shows that, even after surface treatment, it still can contain a considerable amount of solid particles. These particles can bridge formation pores and cause a considerable reduction in the injectivity. To ensure good injectivity over a longer term, the concentration and size of these solids should not exceed certain limits. In this article core flood tests were carried out to simulate high rate injectors. The injected brine contained solid particles in different concentrations and sizes. Particle concentration was between 5 and 20 ppm and the particle mean size was between 2 and 9 {mu}m. The results were presented as damaging ratio versus pore volume injected. Contrarily to previous studies instead of using experimental results in calibrating or evaluating certain theoretical models, the results in this study were directly fitted to produce equations which can predict the extent of damage caused by injected water by knowing the mean size and concentration of the solid particles contained in that water. (orig.)

  3. Building a Data Science capability for USGS water research and communication

    Science.gov (United States)

    Appling, A.; Read, E. K.

    2015-12-01

    Interpreting and communicating water issues in an era of exponentially increasing information requires a blend of domain expertise, computational proficiency, and communication skills. The USGS Office of Water Information has established a Data Science team to meet these needs, providing challenging careers for diverse domain scientists and innovators in the fields of information technology and data visualization. Here, we detail the experience of building a Data Science capability as a bridging element between traditional water resources analyses and modern computing tools and data management techniques. This approach includes four major components: 1) building reusable research tools, 2) documenting data-intensive research approaches in peer reviewed journals, 3) communicating complex water resources issues with interactive web visualizations, and 4) offering training programs for our peers in scientific computing. These components collectively improve the efficiency, transparency, and reproducibility of USGS data analyses and scientific workflows.

  4. Protection of historic buildings against environmental pollution of vibrations

    Directory of Open Access Journals (Sweden)

    Kowalska-Koczwara Alicja

    2016-01-01

    Full Text Available Historic buildings in Poland are largely neglected objects that small percentage is preserved in its original form. Unrelenting in the case of historic buildings is a time that brings with it the natural processes of aging of buildings, but also the history of the object which is often marked by military conflicts, fires or even incompetently carried out reconstruction. Nowadays historic buildings are also destroyed by the rapid development of infrastructure and residential construction. This development could lead to changes of water in the soil, make changes in the geologic al structure or cause exposure of the historic building to the new influences (eg. traffic vibrations, to which building has not been subjected so far. Vibrations are often omitted in environmental issues, although the protection against noise and vibration has its place in the Law on Environmental Protection. This article presents the methodology for the measurement and interpretation of vibration influence on historic buildings and the assessment methods of technical condition of historic building on the example of dynamic measurements made on St. Nicholas Church in Krakow. The importance of well-done crack-by-crack documentation and characterization of damages based on damage index is shown. Difficulties that can be encountered when determining the causes of technical condition of historic buildings are also shown. Based on the example of the Church in the article are also given the possible protection solutions of historic structures from vibrations.

  5. Flexibility-based structural damage identification using Gauss ...

    Indian Academy of Sciences (India)

    ... structural damages in civil infrastructure, such as high-rise buildings, long-span ... tion is widely used in bridges and buildings today because it is easy and ..... The objective of this paper is to design a mathematical algo- ..... Single damage.

  6. Salvaging and Conserving Water Damaged Photographic Materials

    Science.gov (United States)

    Suzuki, Ryuji

    Degradation of water damaged photographic materials is discussed; the most vulnerable elements are gelatin layers and silver image. A simple and inexpensive chemical treatment is proposed, consisting of a bath containing a gelatin-protecting biocide and a silver image protecting agent. These ingredients were selected among those used in manufacturing of silver halide photographic emulsions or processing chemicals. Experiments confirmed that this treatment significantly reduced oxidative attacks to silver image and bacterial degradation of gelatin layers. The treated material was also stable under intense light fading test. Method of hardening gelatin to suppress swelling is also discussed.

  7. Effect of damage on water retention and gas transport properties geo-materials: Application to geological storage of radioactive waste

    International Nuclear Information System (INIS)

    M'Jahad, S.

    2012-01-01

    In the context of geological disposal of radioactive waste, this work contributes to the characterization of the effect of diffuse damage on the water retention and gas transfer properties of concrete (CEM I and CEM V) selected by Andra, Callovo-Oxfordian argillite (host rock) and argillite / concrete interfaces. This study provides information on the concrete microstructure from Mercury porosimetry intrusion and water retention curves: each concrete has a distinct microstructure, CEM I concrete is characterized by a significant proportion of capillary pores while CEM V concrete has a large proportion of C-S-H pores. Several protocols have been developed in order to damage concrete. The damage reduces water retention capacity of CEM I concrete and increases its gas permeability. Indeed, gas breakthrough pressure decreases significantly for damaged concrete, and this regardless of the type of concrete. For argillite, the sample mass increases gradually at RH = 100%, which creates and increases damage in the material. This reduces its ability to retain water. Otherwise, water retention and gas transport properties of argillite are highly dependent of its initial water saturation, which is linked to its damage. Finally, we observed a clogging phenomenon at the argillite/concrete interfaces, which is first mechanical and then hydraulic (and probably chemical) after water injection. This reduces the gas breakthrough pressure interfaces. (author)

  8. Fungal Microbiomes Associated with Green and Non-Green Building Materials.

    Science.gov (United States)

    Coombs, Kanistha; Vesper, Stephen; Green, Brett J; Yermakov, Mikhail; Reponen, Tiina

    2017-01-01

    Water-damaged buildings can lead to fungal growth and occupant health problems. Green building materials, derived from renewable sources, are increasingly utilized in construction and renovations. However, the question as to what fungi will grow on these green compared to non-green materials, after they get wet, has not been adequately studied. By determining what fungi grow on each type of material, the potential health risks can be more adequately assessed. In this study, we inoculated green and non-green pieces of ceiling tile, composite board, drywall, and flooring with indoor dust containing a complex mixture of naturally occurring fungi. The materials were saturated with water and incubated for two months in a controlled environment. The resulting fungal microbiomes were evaluated using ITS amplicon sequencing. Overall, the richness and diversity of the mycobiomes on each pair of green and non-green pieces were not significantly different. However, different genera dominated on each type of material. For example, Aspergillus spp. had the highest relative abundance on green and non-green ceiling tiles and green composite boards, but Peniophora spp. dominated the non-green composite board. In contrast, Penicillium spp. dominated green and non-green flooring samples. Green gypsum board was dominated by Phialophora spp. and Stachybotrys spp., but non-green gypsum board by Myrothecium spp. These data suggest that water-damaged green and non-green building materials can result in mycobiomes that are dominated by fungal genera whose member species pose different potentials for health risks.

  9. Time–frequency analysis of GPR data to investigate the damage of monumental buildings

    International Nuclear Information System (INIS)

    Leucci, Giovanni; Persico, Raffaele; Masini, Nicola

    2012-01-01

    The presence of particular microclimatic conditions inside monumental buildings is responsible for bio-deterioration processes. In many cases, efflorescence and moulds are visible on the facades of several monuments of historical importance. In many other cases, the effects of decay processes are not visible, thus making difficult the diagnosis and the consequent setup of effective rehabilitation and preservation interventions, especially in the presence of a complex geometry and/or a large variability of construction materials. In such cases, a valuable contribution could be provided by geophysical methods (such as electrical resistivity, electromagnetic conductivity, ground-penetrating radar (GPR), etc), which have been proved to be successful tools for sub-surface investigation and characterization of historical buildings. In old monumental buildings, the masonry structures frequently exhibit cracks, voids, detachments and high moisture contrasts that can give rise to reflection events in radar signals. However, the complexity of the geometry and the structural heterogeneity that characterize these old structures often make the GPR results difficult to analyse and interpret. In particular, the spatial variation in GPR signal attenuation can provide important information about the electrical properties of the investigated materials that, in turn, can be used to assess the physical parameters associated with damage. In this paper, we propose an approach that analyses the data in the form of ‘frequency maps’ to evidence absorption losses probably linked to higher moisture content. Two real case histories back up the proposed method. (paper)

  10. Survey of potential light water reactor fuel rod failure mechanisms and damage limits

    International Nuclear Information System (INIS)

    Courtright, E.L.

    1979-07-01

    The findings and conclusions are presented of a survey to evaluate current information applicable to the development of fuel rod damage and failure limits for light water reactor fuel elements. The survey includes a review of past fuel failures, and identifies potential damage and failure mechanisms for both steady state operating conditions and postulated accident events. Possible relationships between the various damage and failure mechanisms are also proposed. The report identifies limiting criteria where possible, but concludes that sufficient data are not currently available in many important areas

  11. Tsunami vulnerability of buildings and people in South Java - field observations after the July 2006 Java tsunami

    Science.gov (United States)

    Reese, S.; Cousins, W. J.; Power, W. L.; Palmer, N. G.; Tejakusuma, I. G.; Nugrahadi, S.

    2007-10-01

    A team of scientists from New Zealand and Indonesia undertook a reconnaissance mission to the South Java area affected by the tsunami of 17 July 2006. The team used GPS-based surveying equipment to measure ground profiles and inundation depths along 17 transects across affected areas near the port city of Cilacap and the resort town of Pangandaran. The purpose of the work was to acquire data for calibration of models used to estimate tsunami inundations, casualty rates and damage levels. Additional information was gathered from interviews with eyewitnesses. The degree of damage observed was diverse, being primarily dependant on water depth and the building construction type. Water depths were typically 2 to 4 m where housing was seriously damaged. Damage levels ranged from total for older brick houses, to about 50% for newer buildings with rudimentary reinforced-concrete beams and columns, to 5-20% for engineered residential houses and multi-storey hotels with heavier RC columns. "Punchout" of weak brick walls was widespread. Despite various natural warning signs very few people were alerted to the impending tsunami. Hence, the death toll was significant, with average death and injury rates both being about 10% of the people exposed, for water depths of about 3 m.

  12. Seismic resistance of equipment and building service systems: review of earthquake damage design requirements, and research applications in the USA

    International Nuclear Information System (INIS)

    Skjei, R.E.; Chakravartula, B.C.; Yanev, P.I.

    1979-01-01

    The history of earthquake damage and the resulting code design requirements for earthquake hazard mitigation for equipment in the USA is reviewed. Earthquake damage to essential service systems is summarized; observations for the 1964 Alaska and the 1971 San Fernando, California, earthquakes are stressed, and information from other events is included. USA building codes that reflect lessons learned from these earthquakes are discussed; brief summaries of widely used codes are presented. In conclusion there is a discussion of the desirability of adapting advanced technological concepts from the nuclear industry to equipment in conventional structures. (author)

  13. Evaluation of tritiated water retention capacity of fusion reactor concrete building

    International Nuclear Information System (INIS)

    Numata, S.; Fujii, Y.; Okamoto, M.

    1992-01-01

    In this paper the diffusion of tritiated water vapor into concrete walls is studied to evaluate tritiated water retention capacity of a fusion reactor concrete building. Using a model of the tritiated water diffusion determined form experimental results, depth profiles of tritiated water in concrete are calculated in the case of being exposed to air containing tritiated water vapor during the normal operational condition of a fusion reactor. A 0.5-m-thick concrete is sufficient for reactor hall walls from a viewpoint of the tritium containment

  14. Solar Water Heater Systems for Building Trades Class.

    Science.gov (United States)

    Ryan, Milton; And Others

    This teaching unit serves as a guide for the installation of active solar water heating systems. It contains a project designed for use with secondary level students of a building trades class. Students typically would meet 2 to 3 hours per day and would be able to complete the activity within a 1-week time period. Objectives of this unit include:…

  15. Annual performance of building-integrated photovoltaic/water-heating system for warm climate application

    International Nuclear Information System (INIS)

    Chow, T.T.; Chan, A.L.S.; Fong, K.F.; Lin, Z.; He, W.; Ji, J.

    2009-01-01

    A building-integrated photovoltaic/water-heating (BiPVW) system is able to generate higher energy output per unit collector area than the conventional solar systems. Through computer simulation with energy models developed for this integrative solar system in Hong Kong, the results showed that the photovoltaic/water-heating (PVW) system has economic advantages over the conventional photovoltaic (PV) installation. The system thermal performance under natural water circulation was found better than the pump-circulation mode. For a specific BiPVW system at a vertical wall of a fully air-conditioned building and with collectors equipped with flat-box-type thermal absorber and polycrystalline silicon cells, the year-round thermal and cell conversion efficiencies were found respectively 37.5% and 9.39% under typical Hong Kong weather conditions. The overall heat transmission through the PVW wall is reduced to 38% of the normal building facade. When serving as a water pre-heating system, the economical payback period was estimated around 14 years. This greatly enhances the PV market opportunities. (author)

  16. Tsunami vulnerability of buildings and people in South Java – field observations after the July 2006 Java tsunami

    Directory of Open Access Journals (Sweden)

    S. Nugrahadi

    2007-10-01

    Full Text Available A team of scientists from New Zealand and Indonesia undertook a reconnaissance mission to the South Java area affected by the tsunami of 17 July 2006. The team used GPS-based surveying equipment to measure ground profiles and inundation depths along 17 transects across affected areas near the port city of Cilacap and the resort town of Pangandaran. The purpose of the work was to acquire data for calibration of models used to estimate tsunami inundations, casualty rates and damage levels. Additional information was gathered from interviews with eyewitnesses. The degree of damage observed was diverse, being primarily dependant on water depth and the building construction type. Water depths were typically 2 to 4 m where housing was seriously damaged. Damage levels ranged from total for older brick houses, to about 50% for newer buildings with rudimentary reinforced-concrete beams and columns, to 5–20% for engineered residential houses and multi-storey hotels with heavier RC columns. "Punchout" of weak brick walls was widespread. Despite various natural warning signs very few people were alerted to the impending tsunami. Hence, the death toll was significant, with average death and injury rates both being about 10% of the people exposed, for water depths of about 3 m.

  17. HEAT LOSS FROM HOT WATER SUPPLY LINE IN A RESIDENTIAL BUILDING

    OpenAIRE

    近藤, 修平; 鉾井, 修一

    2011-01-01

    In order to the evaluate heat loss from hot water supply lines in a residential building, hot water demand in a house in Chiba prefecture was measured and analyzed. The following results were obtained. 1. The heat loss of the hot water supply line was about 132kJ for the shower and 110kJ for the bathtub in winter. Since the temperature difference between the inlet and outlet of the hot water supply line is small, the measured heat loss from the hot water supply line sometimes becomes negative...

  18. Shock vibration and damage responses of primary auxiliary buildings from aircraft impact

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Sang Shup [Korea Atomic Energy Research Institute, 1045 Daeduk-daero, Dukjin-dong, Yuseong-gu, Daejeon 305-303 (Korea, Republic of); Department of Civil and Environmental Engineering, Hanyang University, Seoul 133-791 (Korea, Republic of); Hahm, Daegi [Korea Atomic Energy Research Institute, 1045 Daeduk-daero, Dukjin-dong, Yuseong-gu, Daejeon 305-303 (Korea, Republic of); Park, Taehyo, E-mail: cepark@hanyang.ac.kr [Department of Civil and Environmental Engineering, Hanyang University, Seoul 133-791 (Korea, Republic of)

    2016-12-15

    Highlights: • Aircraft impact analyses of PABs were performed using both the force-time history method and missile-target interaction method. • The jet fuel was considered by using the added mass modeling method and SPH method, respectively. • The FRS and the structural integrity of the external wall of the PABs against an aircraft impact were analyzed. - Abstract: Safety assessments on nuclear power plants (NPPs) subjected to an aircraft impact (AI) caused by terrorists are pivotal focuses for amelioration of present. To date, most studies have mainly focused on structure responses and the integrity of the containment building at a nuclear island (NI) subjected to AI. However, the safety assessment of internal equipment and components by shock vibration as well as the structure damage induced by AI are also important. In this study, aircraft impact analyses (AIA) of primary auxiliary buildings (PABs) were carried out using both the force–time history method and the missile–target interaction method. For the AIA, the jet fuel was taken into account by using the added mass modeling method and the smooth particles hydrodynamics (SPH) method, respectively. In addition, the floor response spectra (FRS) and the structural integrity of the external wall of the PAB against an AI were analyzed. Finally, the difference in the FRS at the location of the components on both sides of the bay was analyzed.

  19. Quantitative assessment of intergranular damage due to PWR primary water exposure in structural Ni-based alloys

    International Nuclear Information System (INIS)

    Ter-Ovanessian, Benoît; Deleume, Julien; Cloué, Jean-Marc; Andrieu, Eric

    2013-01-01

    Highlights: ► IG damage occurred on Ni-base alloys during exposure at high temperature water. ► Two characterization methods yield a tomographic analysis of this IG damage. ► Connected or isolated intergranular oxygen/oxide penetrations are quantified. ► Such quantitative description provides information on IGSCC susceptibility. - Abstract: Two nickel-based alloys, alloy 718 and alloy 600, known to have different resistances to IGSCC, were exposed to a simulated PWR primary water environment at 360 °C for 1000 h. The intergranular oxidation damage was analyzed in detail using an original approach involving two characterization methods (Incremental Mechanical Polishing/Microcopy procedure and SIMS imaging) which yielded a tomographic analysis of the damage. Intergranular oxygen/oxide penetrations occurred either as connected or isolated penetrations deep under the external oxide/substrate interface as far as 10 μm for alloy 600 and only 4 μm for alloy 718. Therefore, assessing this damage precisely is essential to interpret IGSCC susceptibility.

  20. Economic and Technical Investigation of Grey Water Reuse in High-Rise Buildings in Iran

    Directory of Open Access Journals (Sweden)

    Ashkan Rohani Farahmand

    2017-07-01

    Full Text Available Iran is located in an arid and semi-arid zone with limited water resources. In urban areas where water supplies are short, effluents from wastewater treatment plants can be considered as a reliable alternative source to supply water, especially for such urban uses as flushing and landscape irrigation. The effluents can be used to supply the water for textile, chemical, plastic, and construction industries in addition to agricultural irrigation. While these demands can be supplied from non-potable water resources such as treatment effluents, the water required for drinking and cooking that accounts for only a small portion of the total consumption must be supplied from those resources that conform to quality standards. The objective of the present study was to develop incentive plans and innovative designs that would assist builders and inhabitants of high-rise buildings to implement and employ grey water reuse systems. The study also investigated the effects of emoploying two-storage septic tanks to improve such water parameters as BOD, COD, N, P, and TSS. Given the fact that water connection charges in Iran are only a function of total land and building areas with volumetric parameters excluded, the current pricing system for water and sewage connections needs to be revisited and duly adjusted. The additional costs of systems required for segregating black water from grey water and recirculating treated water within the building may not be economically justifiable and, thus, the incentive plans are expected to provide the required justification for both the water industry and the builders.

  1. Building America Case Study: Addressing Multifamily Piping Losses with Solar Hot Water, Davis, California

    Energy Technology Data Exchange (ETDEWEB)

    2016-12-01

    Solar thermal water heating is most cost effective when applied to multifamily buildings and some states offer incentives or other inducements to install them. However, typical solar water heating designs do not allow the solar generated heat to be applied to recirculation losses, only to reduce the amount of gas or electric energy needed for hot water that is delivered to the fixtures. For good reasons, hot water that is recirculated through the building is returned to the water heater, not to the solar storage tank. The project described in this report investigated the effectiveness of using automatic valves to divert water that is normally returned through the recirculation piping to the gas or electric water heater instead to the solar storage tank. The valves can be controlled so that the flow is only diverted when the returning water is cooler than the water in the solar storage tank.

  2. Comparison of computer codes relative to the aerosol behavior in the reactor containment building during severe core damage accidents in a PWR

    International Nuclear Information System (INIS)

    Fermandjian, J.; Bunz, H.; Dunbar, I.; Gauvain, J.; Ricchena, R.

    1986-01-01

    The present study concerns a comparative exercise, performed within the framework of the Commission of the European Communities, of the computer codes (AEROSIM-M, UK; AEROSOLS/B1, France; CORRAL-2, CEC and NAUA Mod5, Germany) used in order to assess the aerosol behavior in the reactor containment building during severe core damage accidents in a PWR. Topics considered in this paper include aerosols, containment buildings, reactor safety, fission product release, reactor cores, meltdown, and monitoring

  3. Evaluation of Crawlspace Retrofits in Multifamily Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Rudd, A.

    2014-09-01

    In 2011 and early 2012, Building Science Corporation (BSC) collaborated with Innova Services Corporation on a multifamily community unvented crawlspace retrofit project at Oakwood Gardens in Lansdale, Pennsylvania. BSC provided design consulting services and pre- and post-retrofit evaluation, testing, and data monitoring. The existing condition was a vented crawlspace with an uninsulated floor between the crawlspace and the dwelling units above. The crawlspace was therefore a critically weak link in the building enclosure and was ripe for improvement. Saving energy was the primary interest and goal, but the greatest challenge in this unvented crawlspace retrofit project was working through a crawlspace bulk water intrusion problem caused by inadequate site drainage, window well drainage, foundation wall drainage, and a rising water table during rainy periods. While the unvented crawlspace retrofit was effective in reducing heat loss, and the majority of the bulk water drainage problems had been resolved, the important finding was that some of the wood joists embedded in masonry pockets behind the brick veneer were showing signs of moisture damage.

  4. On Monte Carlo estimation of radiation damage in light water reactor systems

    International Nuclear Information System (INIS)

    Read, Edward A.; Oliveira, Cassiano R.E. de

    2010-01-01

    There has been a growing need in recent years for the development of methodologies to calculate damage factors, namely displacements per atom (dpa), of structural components for Light Water Reactors (LWRs). The aim of this paper is discuss and highlight the main issues associated with the calculation of radiation damage factors utilizing the Monte Carlo method. Among these issues are: particle tracking and tallying in complex geometries, dpa calculation methodology, coupled fuel depletion and uncertainty propagation. The capabilities of the Monte Carlo code Serpent such as Woodcock tracking and burnup are assessed for radiation damage calculations and its capability demonstrated and compared to those of the MCNP code for dpa calculations of a typical LWR configuration involving the core vessel and the downcomer. (author)

  5. An experimental study on tissue damage following subcutaneous injection of water soluble contrast media

    International Nuclear Information System (INIS)

    Kim, Seung Hyup; Park, Jae Hyung; Kang, Heung Sik; Kim, Chu Wan; Han, Man Chung; Kim, Yong Il

    1989-01-01

    The water soluble contrast media cause tissue necrosis infrequently by extravasation during intravenous injection in various radiological examinations. However, it has not been well documented that what kind and what concentration of contrast media can cause tissue necrosis. And also, the mechanism of tissue necrosis by extravasated contrast media has not been well known. The purpose of this experimental study was to evaluate the frequency and severity of tissue damage following subcutaneous injection of various water soluble contrast media to investigate the characteristics of the contrast media acting on the tissue damage, and to provide the basic data for the clinical application. Meglumine ioxithalamate,sodium and meglumine ioxithalamate, iopromide, iopamidol, ioxaglate,meglumine diatrizoate and sodium diatrizoate of various iodine content and osmolality were injected into subcutaneous tissue of the dorsum of 970 feet of 485 rats. The tissue reaction of injection sites were grossly examined with period from 1 day to 8 weeks after the injection. Representative gross changes were correlated with histologic findings. The results were as follows; 1. The basic tissue damage by extravasated contrast media was acute and chronic inflammatory reaction of the soft tissue with subsequent progress into the hemorrhagic and necrotizing lesion. 2. Lager volume of contrast media caused more severe tissue damage. 3. Contrast media of higher osmolality caused more severe tissue damage. 4. At same osmolality, contrast media of higher iodine content caused more severe tissue damage

  6. Applying water cooled air conditioners in residential buildings in Hong Kong

    International Nuclear Information System (INIS)

    Chen Hua; Lee, W.L.; Yik, F.W.H.

    2008-01-01

    The objective of this study is to conduct a realistic prediction of the potential energy saving for using water cooled air conditioners in residential buildings in Hong Kong. A split type air conditioner with air cooled (AAC) and water cooled (WAC) options was set up for experimental study at different indoor and outdoor conditions. The cooling output, power consumption and coefficient of performance (COP) of the two options were measured and calculated for comparison. The experimental results showed that the COP of the WAC is, on average, 17.4% higher than that of the AAC. The results were used to validate the mathematical models formulated for predicting the performance of WACs and AACs at different operating conditions and load characteristics. While the development of the mathematical models for WACs was reported in an earlier paper, this paper focuses on the experimental works for the AAC. The mathematical models were further used to predict the potential energy saving for application of WACs in residential buildings in Hong Kong. The predictions were based on actual building developments and realistic operating characteristics. The overall energy savings were estimated to be around 8.7% of the total electricity consumption for residential buildings in Hong Kong. Wider use of WACs in subtropical cities is, therefore, recommended

  7. Damage assessment in Braunsbach 2016: data collection and analysis for an improved understanding of damaging processes during flash floods

    Science.gov (United States)

    Laudan, Jonas; Rözer, Viktor; Sieg, Tobias; Vogel, Kristin; Thieken, Annegret H.

    2017-12-01

    Flash floods are caused by intense rainfall events and represent an insufficiently understood phenomenon in Germany. As a result of higher precipitation intensities, flash floods might occur more frequently in future. In combination with changing land use patterns and urbanisation, damage mitigation, insurance and risk management in flash-flood-prone regions are becoming increasingly important. However, a better understanding of damage caused by flash floods requires ex post collection of relevant but yet sparsely available information for research. At the end of May 2016, very high and concentrated rainfall intensities led to severe flash floods in several southern German municipalities. The small town of Braunsbach stood as a prime example of the devastating potential of such events. Eight to ten days after the flash flood event, damage assessment and data collection were conducted in Braunsbach by investigating all affected buildings and their surroundings. To record and store the data on site, the open-source software bundle KoBoCollect was used as an efficient and easy way to gather information. Since the damage driving factors of flash floods are expected to differ from those of riverine flooding, a post-hoc data analysis was performed, aiming to identify the influence of flood processes and building attributes on damage grades, which reflect the extent of structural damage. Data analyses include the application of random forest, a random general linear model and multinomial logistic regression as well as the construction of a local impact map to reveal influences on the damage grades. Further, a Spearman's Rho correlation matrix was calculated. The results reveal that the damage driving factors of flash floods differ from those of riverine floods to a certain extent. The exposition of a building in flow direction shows an especially strong correlation with the damage grade and has a high predictive power within the constructed damage models. Additionally

  8. The analysis of the hot water consumption and energy performance before and after renovation in multi-apartment buildings

    Science.gov (United States)

    Tumanova, K.; Borodinecs, A.; Geikins, A.

    2017-10-01

    The article presents the results of hot water supply system analysis. Taking into account that the current consumption of hot water differs from normative values, real measured data of hot water consumption in multi-apartment buildings from year 2013 until year 2015 have been analyzed. Also, the thermal energy consumption for hot water preparation has been analyzed. Based on aggregated data and taking into account the fact that renovated systems of hot water supply in existing multi-apartment buildings have same pipelines’ diameters, it was analyzed how these systems are economically and energy efficient. For the study, residential buildings in Riga, which have different architectural and engineering solutions for hot water supply systems, were selected. The study was based on thermal energy consumption measurements, which were taken at the individual heating system’s manifolds. This study was done in order to develop database on hot water consumption in civil buildings and define difference in key performance criteria in unclassified buildings. Obtained results allows to reach European Regional Development Fund project “NEARLY ZERO ENERGY SOLUTIONS FOR UNCLASSIFIED BUILDINGS” Nr. 1.1.1.116A048 main targets.

  9. NASA's Contribution to Water Research, Applications and Capacity Building in the America's

    Science.gov (United States)

    Toll, D. L.; Searby, N. D.; Doorn, B.; Lawford, R. G.; Entin, J. K.; Mohr, K. I.; Lee, C.; NASA International Water Team

    2013-05-01

    NASA's water research, applications and capacity building activities use satellites and models to contribute to regional water information and solutions for the Americas. Free and open exchange of Earth data observations and products helps engage and improve integrated observation networks and enables national and multi-national regional water cycle research and applications. NASA satellite and modeling products provide a huge volume of valuable data extending back over 50 years across a broad range of spatial (local to global) and temporal (hourly to decadal) scales and include many products that are available in near real time (see earthdata.nasa.gov). In addition, NASA's work in hydrologic predictions are valuable for: 1) short-term and hourly data that is critical for flood and landslide warnings; 2) mid-term predictions of days to weeks useful for reservoir planning and water allocation, and 3) long term seasonal to decadal forecasts helpful for agricultural and irrigation planning, land use planning, and water infrastructure development and planning. To further accomplish these objectives NASA works to actively partner with public and private groups (e.g. federal agencies, universities, NGO's, and industry) in the U.S. and internationally to ensure the broadest use of its satellites and related information and products and to collaborate with regional end users who know the regions and their needs best. Through these data, policy and partnering activities, NASA addresses numerous water issues including water scarcity, the extreme events of drought and floods, and water quality so critical to the Americas. This presentation will outline and describe NASA's water related research, applications and capacity building programs' efforts to address the Americas' critical water challenges. This will specifically include water activities in NASA's programs in Terrestrial Hydrology (e.g., land-atmosphere feedbacks and improved stream flow estimation), Water Resources

  10. The Effects of Multiple Cold Water Immersions on Indices of Muscle Damage

    Science.gov (United States)

    Goodall, Stuart; Howatson, Glyn

    2008-01-01

    The aim of this investigation was to elucidate the efficacy of repeated cold water immersions (CWI) in the recovery of exercise induced muscle damage. A randomised group consisting of eighteen males, mean ± s age, height and body mass were 24 ± 5 years, 1.82 ± 0.06 m and 85.7 ± 16.6 kg respectively, completed a bout of 100 drop jumps. Following the bout of damaging exercise, participants were randomly but equally assigned to either a 12 min CWI (15 ± 1 °C; n = 9) group who experienced immersions immediately post-exercise and every 24 h thereafter for the following 3 days, or a control group (no treatment; n = 9). Maximal voluntary contraction (MVC) of the knee extensors, creatine kinase activity (CK), muscle soreness (DOMS), range of motion (ROM) and limb girth were measured pre-exercise and then for the following 96 h at 24 h increments. In addition MVC was also recorded immediately post-exercise. Significant time effects were seen for MVC, CK, DOMS and limb girth (p 0.05). These results suggest that repeated CWI do not enhance recovery from a bout of damaging eccentric contractions. Key pointsCryotherapy, particularly cold water immersions are one of the most common interventions used in order to enhance recovery post-exercise.There is little empirical evidence demonstrating benefits from cold water immersions. Research evidence is equivocal, probably due to methodological inconsistencies.Our results show that the cryotherapy administered did not attenuate any markers of EIMD or enhance the recovery of function.We conclude that repeated cold water immersions are ineffective in the recovery from heavy plyometric exercise and suggest athletes and coaches should use caution before using this intervention as a recovery strategy PMID:24149455

  11. Tree-based flood damage modeling of companies: Damage processes and model performance

    Science.gov (United States)

    Sieg, Tobias; Vogel, Kristin; Merz, Bruno; Kreibich, Heidi

    2017-07-01

    Reliable flood risk analyses, including the estimation of damage, are an important prerequisite for efficient risk management. However, not much is known about flood damage processes affecting companies. Thus, we conduct a flood damage assessment of companies in Germany with regard to two aspects. First, we identify relevant damage-influencing variables. Second, we assess the prediction performance of the developed damage models with respect to the gain by using an increasing amount of training data and a sector-specific evaluation of the data. Random forests are trained with data from two postevent surveys after flood events occurring in the years 2002 and 2013. For a sector-specific consideration, the data set is split into four subsets corresponding to the manufacturing, commercial, financial, and service sectors. Further, separate models are derived for three different company assets: buildings, equipment, and goods and stock. Calculated variable importance values reveal different variable sets relevant for the damage estimation, indicating significant differences in the damage process for various company sectors and assets. With an increasing number of data used to build the models, prediction errors decrease. Yet the effect is rather small and seems to saturate for a data set size of several hundred observations. In contrast, the prediction improvement achieved by a sector-specific consideration is more distinct, especially for damage to equipment and goods and stock. Consequently, sector-specific data acquisition and a consideration of sector-specific company characteristics in future flood damage assessments is expected to improve the model performance more than a mere increase in data.

  12. Hydraulic logic gates: building a digital water computer

    Science.gov (United States)

    Taberlet, Nicolas; Marsal, Quentin; Ferrand, Jérémy; Plihon, Nicolas

    2018-03-01

    In this article, we propose an easy-to-build hydraulic machine which serves as a digital binary computer. We first explain how an elementary adder can be built from test tubes and pipes (a cup filled with water representing a 1, and empty cup a 0). Using a siphon and a slow drain, the proposed setup combines AND and XOR logical gates in a single device which can add two binary digits. We then show how these elementary units can be combined to construct a full 4-bit adder. The sequencing of the computation is discussed and a water clock can be incorporated so that the machine can run without any exterior intervention.

  13. Solar Water Heater

    Science.gov (United States)

    1993-01-01

    As a Jet Propulsion Laboratory (JPL) scientist Dr. Eldon Haines studied the solar energy source and solar water heating. He concluded he could build a superior solar water heating system using the geyser pumping principle. He resigned from JPL to develop his system and later form Sage Advance Corporation to market the technology. Haines' Copper Cricket residential system has no moving parts, is immune to freeze damage, needs no roof-mounted tanks, and features low maintenance. It provides 50-90 percent of average hot water requirements. A larger system, the Copper Dragon, has been developed for commercial installations.

  14. NORTH PORTAL-HOT WATER CALCULATION-SHOP BUILDING No.5006

    International Nuclear Information System (INIS)

    R. Blackstone

    2006-01-01

    The purpose of this design analysis and calculation is to determine the demand for domestic cold water and to size the supply main for the Shop Building No.5006 in accordance with the Uniform Plumbing Code (UPC) (Section 4.4.1) and the U.S. Department of Energy, Order 6430.1A-1540 (Section 4.4.2)

  15. Mining-induced surface damage and the study of countermeasures

    International Nuclear Information System (INIS)

    Cui Jixian

    1994-01-01

    Coal constitutes China's major energy resource. The majority of the coal is produced from underground mining operations. Surface subsidence may amount to 80% of the thickness of the seam mined, while the subsided volume is around 60% of the mined volume underground. An area of 20 hectares of land will be affected with each 1 million tons of coal mined, thereby causing severe surface damage. Following a description of the characteristics of surface damages due to underground mining disturbance, this paper elaborates on the damage prediction method, standards applied for evaluating the damages experienced by surface buildings, land reclamation methods in subsided area, measures for reinforcing and protecting buildings in mining-affected areas, and performance of antideformation buildings

  16. Damage Detection on Sudden Stiffness Reduction Based on Discrete Wavelet Transform

    Directory of Open Access Journals (Sweden)

    Bo Chen

    2014-01-01

    Full Text Available The sudden stiffness reduction in a structure may cause the signal discontinuity in the acceleration responses close to the damage location at the damage time instant. To this end, the damage detection on sudden stiffness reduction of building structures has been actively investigated in this study. The signal discontinuity of the structural acceleration responses of an example building is extracted based on the discrete wavelet transform. It is proved that the variation of the first level detail coefficients of the wavelet transform at damage instant is linearly proportional to the magnitude of the stiffness reduction. A new damage index is proposed and implemented to detect the damage time instant, location, and severity of a structure due to a sudden change of structural stiffness. Numerical simulation using a five-story shear building under different types of excitation is carried out to assess the effectiveness and reliability of the proposed damage index for the building at different damage levels. The sensitivity of the damage index to the intensity and frequency range of measurement noise is also investigated. The made observations demonstrate that the proposed damage index can accurately identify the sudden damage events if the noise intensity is limited.

  17. Water supply facility damage and water resource operation at disaster base hospitals in miyagi prefecture in the wake of the Great East Japan Earthquake.

    Science.gov (United States)

    Matsumura, Takashi; Osaki, Shizuka; Kudo, Daisuke; Furukawa, Hajime; Nakagawa, Atsuhiro; Abe, Yoshiko; Yamanouchi, Satoshi; Egawa, Shinichi; Tominaga, Teiji; Kushimoto, Shigeki

    2015-04-01

    The aim of this study was to shed light on damage to water supply facilities and the state of water resource operation at disaster base hospitals in Miyagi Prefecture (Japan) in the wake of the Great East Japan Earthquake (2011), in order to identify issues concerning the operational continuity of hospitals in the event of a disaster. In addition to interview and written questionnaire surveys to 14 disaster base hospitals in Miyagi Prefecture, a number of key elements relating to the damage done to water supply facilities and the operation of water resources were identified from the chronological record of events following the Great East Japan Earthquake. Nine of the 14 hospitals experienced cuts to their water supplies, with a median value of three days (range=one to 20 days) for service recovery time. The hospitals that could utilize well water during the time that water supply was interrupted were able to obtain water in quantities similar to their normal volumes. Hospitals that could not use well water during the period of interruption, and hospitals whose water supply facilities were damaged, experienced significant disruption to dialysis, sterilization equipment, meal services, sanitation, and outpatient care services, though the extent of disruption varied considerably among hospitals. None of the hospitals had determined the amount of water used for different purposes during normal service or formulated a plan for allocation of limited water in the event of a disaster. The present survey showed that it is possible to minimize the disruption and reduction of hospital functions in the event of a disaster by proper maintenance of water supply facilities and by ensuring alternative water resources, such as well water. It is also clear that it is desirable to conclude water supply agreements and formulate strategic water allocation plans in preparation for the eventuality of a long-term interruption to water services.

  18. Building damage concentrated in Longtoushan town during the 2014 Ms. 6.5 Ludian earthquake, Yunnan, China: examination of cause and implications based on ground motion and vulnerability analyses

    Science.gov (United States)

    Wang, Xin; Kurahashi, Susumu; Wu, Hao; Si, Hongjun; Ma, Qiang; Dang, Ji; Tao, Dongwang; Feng, Jiwei; Irikura, Kojiro

    2017-09-01

    Though the 2014 Ludian Earthquake had only a moderate magnitude (Ms 6.5), high-level ground motions of almost 1 g occurred at Longtoushan Town (seismic station 53LLT), which located near the intersection of a conjugate-shaped seismogenic fault. The building damages on the pluvial fan and the river terrace at Longtoushan was clearly different. In order to examine the generation of the large acceleration at 53LLT, the focal mechanisms and the rupture processes of the conjugate-shaped seismogenic fault were determined. We found that there were two continuous impulsive waves in the records of 53LLT that were generated from two different faults, the Baogunao fault and the Xiaohe fault, respectively. Site effects on the pluvial fan and the river terrace at Longtoushan Town and their relations to different building damages were examined. We found that the predominant period at the pluvial fan was about 0.25 s, close to the fundamental natural period of multi-story confined masonry buildings. Ground motions on the pluvial fan and the river terrace were simulated through convolving synthesized bedrock motions with the transfer functions, which were analyzed using the one-dimensional underground velocity structures identified from H/V spectral ratios of ambient noise. Building collapse ratios (CRs) are estimated based on the vulnerability function of the 2008 Wenchuan Earthquake and are compared with the observed values. We found that the observed building CRs on the pluvial fan are much higher than the estimated values. High-level ground shaking that is far beyond the design level was a reason for serious building damage.

  19. Impact of Water Chemistry, Pipe Material and Stagnation on the Building Plumbing Microbiome.

    Directory of Open Access Journals (Sweden)

    Pan Ji

    Full Text Available A unique microbiome establishes in the portion of the potable water distribution system within homes and other buildings (i.e., building plumbing. To examine its composition and the factors that shape it, standardized cold water plumbing rigs were deployed at the treatment plant and in the distribution system of five water utilities across the U.S. Three pipe materials (copper with lead solder, CPVC with brass fittings or copper/lead combined pipe were compared, with 8 hour flush cycles of 10 minutes to simulate typical daily use patterns. High throughput Illumina sequencing of 16S rRNA gene amplicons was employed to profile and compare the resident bulk water bacteria and archaea. The utility, location of the pipe rig, pipe material and stagnation all had a significant influence on the plumbing microbiome composition, but the utility source water and treatment practices were dominant factors. Examination of 21 water chemistry parameters suggested that the total chlorine concentration, pH, P, SO42- and Mg were associated with the most of the variation in bulk water microbiome composition. Disinfectant type exerted a notably low-magnitude impact on microbiome composition. At two utilities using the same source water, slight differences in treatment approaches were associated with differences in rare taxa in samples. For genera containing opportunistic pathogens, Utility C samples (highest pH of 9-10 had the highest frequency of detection for Legionella spp. and lowest relative abundance of Mycobacterium spp. Data were examined across utilities to identify a true universal core, special core, and peripheral organisms to deepen insight into the physical and chemical factors that shape the building plumbing microbiome.

  20. Preliminary observations of environmental damage due to the Gulf War

    International Nuclear Information System (INIS)

    El-Baz, F.

    1992-01-01

    Preparing for and conducting the Gulf War resulted in much damage to the environment of the region. The first and most visible effect is related to the damage caused by oil well fires in terms of air pollution as well as the potential damage to the petroleum reservoirs. The second detrimental effect has been caused by the oil spill in the Gulf water. Hundreds of miles of the western coastline of the Gulf are already covered with oil. Petroleum 'mats' have settled on coral reefs and have reduced Gulf water productivity. Foremost among the irreparable damages are changes to the terrain due to the digging of trenches, building walls of soil and otherwise disturbing the desert pavement in and around Kuwait. Disruption of the, usually, one-grain thick layer of pebbles on the desert floor exposes soil to wind action. Changing the contours of the normally flat land increases resistance to the wind and increases the potential of particle transport until the land is peneplained. This condition will increase the frequency and the ferocity of dust storms in the region. It will also result in the formation of new sand dunes; sand drifts already exist along roads in northern Kuwait. It is believed that the detrimental effects on the atmosphere will last for years, on the Gulf water for decades, and on the desert surface for centuries. (author). 12 refs, 1 fig

  1. Preliminary observations of environmental damage due to the Gulf War

    Energy Technology Data Exchange (ETDEWEB)

    El-Baz, F [Boston Univ., Boston, MA (United States). Center for Remote Sensing

    1992-02-01

    Preparing for and conducting the Gulf War resulted in much damage to the environment of the region. The first and most visible effect is related to the damage caused by oil well fires in terms of air pollution as well as the potential damage to the petroleum reservoirs. The second detrimental effect has been caused by the oil spill in the Gulf water. Hundreds of miles of the western coastline of the Gulf are already covered with oil. Petroleum 'mats' have settled on coral reefs and have reduced Gulf water productivity. Foremost among the irreparable damages are changes to the terrain due to the digging of trenches, building walls of soil and otherwise disturbing the desert pavement in and around Kuwait. Disruption of the, usually, one-grain thick layer of pebbles on the desert floor exposes soil to wind action. Changing the contours of the normally flat land increases resistance to the wind and increases the potential of particle transport until the land is peneplained. This condition will increase the frequency and the ferocity of dust storms in the region. It will also result in the formation of new sand dunes; sand drifts already exist along roads in northern Kuwait. It is believed that the detrimental effects on the atmosphere will last for years, on the Gulf water for decades, and on the desert surface for centuries. (author). 12 refs, 1 fig.

  2. Seismic risk assessment of building based on damaged database of 1995 Hyogoken Nanbu Earthquake; Hyogoken nanbu jishin no hisai database wo mochiita kenchikubutsu no jishin risk hyoka ni kansuru kenkyu

    Energy Technology Data Exchange (ETDEWEB)

    Suwa, H.; Nobata, A.; Seki, M. [Obayashi Corp., Tokyo (Japan)

    2000-01-10

    The objective of this paper is to evaluate a vulnerability function and a repair cost in terms of each structural damage level based on the damaged database of the 1995 Hyogoken Nanbu Earthquake. The seismic risk of a building in Kobe is calculated through the analytical results. As a result, the following are verified : 1. The expectation of vulnerability function, in which peak ground acceleration is taken for seismic intensity, is about 550 cm/s{sup 2} for minor damage, about 700 cm/s{sup 2} for moderate damage, and about 950 cm/s{sup 2} for major damage respectively. However, the coefficient of variation (C. O. V. ) is about 0.5 for all damage levels. 2. The expectation of repair cost per square meter is about 29000 yen for minor damage, about 60000 yen for moderate damage, and about 64000 yen for major damage respectively. However, the variation is very large, for example, the C. O. V. for repair cost varies from 1.2 to 1.6. 3. The seismic risk of a building in Kobe, that is normalized by new construction cost, is about three percent on condition that the design lifetime is assumed to be 50 years. (author)

  3. AP1000 Shield Building Dynamic Response for Different Water Levels of PCCWST Subjected to Seismic Loading considering FSI

    Directory of Open Access Journals (Sweden)

    Daogang Lu

    2015-01-01

    Full Text Available Huge water storage tank on the top of many buildings may affect the safety of the structure caused by fluid-structure interaction (FSI under the earthquake. AP1000 passive containment cooling system water storage tank (PCCWST placed at the top of shield building is a key component to ensure the safety of nuclear facilities. Under seismic loading, water will impact the wall of PCCWST, which may pose a threat to the integrity of the shield building. In the present study, an FE model of AP1000 shield building is built for the modal and transient seismic analysis considering the FSI. Six different water levels in PCCWST were discussed by comparing the modal frequency, seismic acceleration response, and von Mises stress distribution. The results show the maximum von Mises stress emerges at the joint of shield building roof and water around the air inlet. However, the maximum von Mises stress is below the yield strength of reinforced concrete. The results may provide a reference for design of the AP1000 and CAP1400 in the future.

  4. Solar heating and hot water system installed at office building, One Solar Place, Dallas, Texas

    Science.gov (United States)

    1980-01-01

    A solar heating on cooling system is described which is designed to provide 87 percent of the space heating needs, 100 percent of the potable hot water needs and is sized for future absorption cooling. The collection subsystem consists of 28 solargenics, series 76, flat plate collectors with a total area of 1,596 square feet. The solar loop circulates an ethylene glyco water solution through the collectors into a hot water system exchanger. The water storage subsystem consists of a heat exchanger, two 2,300 gallon concrete hot water storage tanks with built in heat exchangers and a back-up electric boiler. The domestic hot water subsystem sends hot water to the 10,200 square feet floor area office building hot water water fixtures. The building cold water system provides make up to the solar loop, the heating loop, and the hot water concrete storage tanks. The design, construction, cost analysis, operation and maintenance of the solar system are described.

  5. Building of Kemijoki water system and the question of Vuotos reservoir. Thinking of the Law; Kemijoen vesistoen rakentaminen ja Vuotos - oikeuden ajattelu

    Energy Technology Data Exchange (ETDEWEB)

    Loeyttyjaervi, M.-L.

    2011-07-01

    The application for Vuotos reservoir and regulating project was denied by the Supreme Administrative Court (KHO 2002:86) by virtue of the Finnish Water Act (264/1961) because of the damages it would have caused to the environment (WA 2:5). The decision opens up two angles from which to examine the law. The first angle is directed towards the history of legal rules on building water power utilities and the weight of natural values in those rules and in legal decisions. The evolution of rules is in this study combined with permits on building Kemijoki water system. The Vuotos decision and the new Water Act (587/2011) becoming into force at the beginning of 2012 are studied in connection with different historical roots that are identified in them. The hegemony of water power in the use of water-courses lasted from the beginning of 1940s until the turn of the decade 1980, when the act protecting Ounasjoki (703/1983) was passed and the government decided (at that time) not to build Vuotos reservoir. In water law the legal weight of natural values has been gradually growing. As a result of recent reforms (implementing EU-directives 2000/60/EY and 2004/35/EY) the law has also meaningfully opened up in the direction of the rights of nature. The second angle that the Vuotos decision opens up is directed towards deeper layers of law. Biocentric and ecocentric materials have been identified to be imported into Finnish law by the constitutional environmental right (the Constitution of Finland section 20, 731/1999). In this research the deeper layers are studied by asking about the possibility of biocentric law and possibility to locate a category of biological community rights into law. The grounds for biocentric thinking are studied in the fields of ethics and both philosophy and theory of law. This study concludes that life is sufficient to justify the inherent worth and even moral and legal rights of a living being. The system of law can be assessed to include features and

  6. Interior insulation – Experimental investigation of hygrothermal conditions and damage evaluation of solid masonry façades in a listed building

    DEFF Research Database (Denmark)

    Odgaard, Tommy; Bjarløv, Søren Peter; Rode, Carsten

    2018-01-01

    Exterior walls in historic multi-storey buildings compared to walls in modern buildings have low thermal resistance, resulting in high energy loss and cold surfaces/floors in cold climates. When restrictions regarding alteration of the exterior appearance exist, interior insulation might be the o......Exterior walls in historic multi-storey buildings compared to walls in modern buildings have low thermal resistance, resulting in high energy loss and cold surfaces/floors in cold climates. When restrictions regarding alteration of the exterior appearance exist, interior insulation might...... be the only possibility to increase occupant comfort. This paper describes an investigation of the hygrothermal influence when applying 100 mm of diffusion open interior insulation to a historic multi-storey solid masonry spandrel. The dormitory room with the insulated spandrel had a normal indoor climate...... showed no risk of damage from the changed hygrothermal conditions when applying interior insulation to a solid masonry spandrel....

  7. Building Capacity to Use NASA Earth Observations in the Water Resource Sector

    Science.gov (United States)

    Childs-Gleason, L. M.; Ross, K. W.; Crepps, G.; Clayton, A.; Ruiz, M. L.; Rogers, L.; Allsbrook, K. N.

    2017-12-01

    The NASA DEVELOP National Program builds capacity to use and apply NASA Earth observations to address environmental concerns around the globe. The DEVELOP model builds capacity in both participants (students, recent graduates, and early and transitioning career professionals) who conduct the projects and partners (decision and policy makers) who are recipients of project methodologies and results. Projects focus on a spectrum of thematic topics, including water resource management which made up 30% of the DEVELOP FY2017 portfolio. During this period, DEVELOP conducted water-focused feasibility studies in collaboration with 22 partners across 13 U.S. states and five countries. This presentation will provide an overview of needs identified, DEVELOP's response, data sources, challenges, and lessons learned.

  8. Fusion of Multi-Temporal Interferometric Coherence and Optical Image Data for the 2016 Kumamoto Earthquake Damage Assessment

    Directory of Open Access Journals (Sweden)

    Nopphawan Tamkuan

    2017-06-01

    Full Text Available Earthquakes are one of the most devastating types of natural disasters, and happen with little to no warning. This study combined Landsat-8 and interferometric ALOS-2 coherence data without training area techniques by classifying the remote sensing ratios of specific features for damage assessment. Waterbodies and highly vegetated areas were extracted by the modified normalized difference water index (MNDWI and normalized difference vegetation index (NDVI, respectively, from after-earthquake images in order to improve the accuracy of damage maps. Urban areas were classified from pre-event interferometric coherence data. The affected areas from the earthquake were detected with the normalized difference (ND between the pre- and co-event interferometric coherence. The results presented three damage types; namely, damage to buildings caused by ground motion, liquefaction, and landslides. The overall accuracy (94% of the confusion matrix was excellent. Results for urban areas were divided into three damage levels (e.g., none–slight, slight–heavy, heavy–destructive at a high (90% overall accuracy level. Moreover, data on buildings damaged by liquefaction and landslides were in good agreement with field survey information. Overall, this study illustrates an effective damage assessment mapping approach that can support post-earthquake management activities for future events, especially in areas where geographical data are sparse.

  9. Production of mycotoxins on artificially and naturally infested building materials

    DEFF Research Database (Denmark)

    Nielsen, Kristian Fog; Gravesen, S.; Nielsen, P.A.

    1999-01-01

    , especially Asp. ustus and Asp. niger produced many unknown secondary metabolites on the building materials. Analyses of wallpaper and glass-fibre wallpaper naturally infested with Asp. versicolor revealed sterigmatocystin and 5-methoxysterigmatocystin. Analyses of naturally infested wallpaper showed that C......In this study, the ability to produce mycotoxins during growth on artificially infested building materials was investigated for Penicillium chrysogenum, Pen. polonicum, Pen. brevicompactum, Chaetomium spp., Aspergillus ustus, Asp. niger, Ulocladium spp., Alternaria spp., and Paecilomyces spp., all...... isolated from water-damaged building materials. Spores from the different isolates of the above mentioned species were inoculated on gypsum board with and without wallpaper and on chipboard with and without wallpaper. Fungal material was scraped off the materials, extracted, and analyzed using high...

  10. Radionuclide distribution in TMI-2 reactor building basement liquids and solids

    International Nuclear Information System (INIS)

    Horan, J.T.; McIsaac, C.V.; Keefer, D.G.

    1984-01-01

    As a result of the TMI-2 accident, approximately 2.46 x 10 6 L of contaminated water were released to the Reactor Building basement. The principal fission product release pathway from the damaged core was through the reactor coolant system (RCS) to the pressurizer, through the pressure-operated relief valve (PORV) on the pressurizer to the Reactor Coolant Drain Tank (RCDT), and then through the RCDT rupture disk to the Reactor Building basement. Since August 1979, a number of efforts have been made to determine the location, quantity, and composition of fission products released to the Reactor Building basement. These efforts have included sampling of the basement water and solids, the basement sump pump recirculation line, the RCDT, and visual surveys using a closed circuit television (CCTV) system. The analysis of basement samples has provided data on the physical and radioisotopic characteristics of the liquids and solids. This paper describes the sample collection techniques and discusses radiochemical analyses results

  11. Creating mold-free buildings: a key to avoiding health effects of indoor molds.

    Science.gov (United States)

    Small, Bruce M

    2003-08-01

    In view of the high costs of building diagnostics and repair subsequent to water damage--as well as the large medical diagnostic and healthcare costs associated with mold growth in buildings--commitment to a philosophy of proactive preventive maintenance for home, apartment, school, and commercial buildings could result in considerable cost savings and avoidance of major health problems among building occupants. The author identifies common causes of mold growth in buildings and summarizes key building design and construction principles essential for preventing mold contamination indoors. Physicians and healthcare workers must be made aware of conditions within buildings that can give rise to mold growth, and of resulting health problems. Timely advice provided to patients already sensitized by exposure to molds could save these individuals, and their families, from further exposures as a result of inadequate building maintenance or an inappropriate choice of replacement housing.

  12. Damage Localization of Severely Damaged RC-Structures Based on Measured Eigenperiods from a Single Response

    DEFF Research Database (Denmark)

    Skjærbæk, P. S.; Nielsen, Søren R.K.; Cakmak, A. S.

    This paper deals with the estimation of the damage location of severely damaged Reinforced Concrete (RC) structures excited by earthquakes. It is assumed that the building is instrumented with a sensor measuring the earthquake acceleration signal at ground surface and a sensor measuring only...

  13. Presence of Legionella spp. in Hot Water Networks of Different Italian Residential Buildings: A Three-Year Survey.

    Science.gov (United States)

    Totaro, Michele; Valentini, Paola; Costa, Anna Laura; Frendo, Lorenzo; Cappello, Alessia; Casini, Beatrice; Miccoli, Mario; Privitera, Gaetano; Baggiani, Angelo

    2017-10-26

    Although the European reports highlight an increase in community-acquired Legionnaires' disease cases, the risk of Legionella spp. in private houses is underestimated. In Pisa (Italy) we performed a three-year survey on Legionella presence in 121 buildings with an independent hot water production (IB); 64 buildings with a central hot water production (CB); and 35 buildings with a solar thermal system for hot water production (TB). From all the 220 buildings Legionella spp. was researched in two hot water samples collected either at the recirculation point or on the first floor and on the last floor, while the potable water quality was analysed in three cold water samples collected at the inlet from the aqueduct network, at the exit from the autoclave, and at the most remote tap. Legionella pneumophila sg1, Legionella pneumophila sg2-16, and non- pneumophila Legionella species were detected in 26% of the hot water networks, mostly in CB and TB. In these buildings we detected correlations between the presence of Legionella and the total chlorine concentration decrease and/or the increase of the temperature. Cold water resulted free from microbiological hazards, with the exception of Serratia liquefaciens and Enterobacter cloacae isolated at the exit from two different autoclaves. We observed an increase in total microbial counts at 22 °C and 37 °C between the samples collected at the most remote taps compared to the ones collected at the inlet from the aqueduct. The study highlights a condition of potential risk for susceptible categories of population and supports the need for measures of risk assessment and control.

  14. Solar heating and hot water system installed at office building, One Solar Place, Dallas, Texas. Final report

    Energy Technology Data Exchange (ETDEWEB)

    1980-06-01

    This document is the Final Report of the Solar Energy System Installed at the First Solar Heated Office Building, One Solar Place, Dallas, Texas. The Solar System was designed to provide 87 percent of the space heating needs, 100 percent of the potable hot water needs and is sized for future absorption cooling. The collection subsystem consists of 28 Solargenics, series 76, flat plate collectors with a total area of 1596 square feet. The solar loop circulates an ethylene glycol-water solution through the collectors into a hot water system heat exchanger. The hot water storage subsystem consists of a heat exchanger, two 2300 gallon concrete hot water storage tanks with built in heat exchangers and a back-up electric boiler. The domestic hot water subsystem sends hot water to the 10,200 square feet floor area office building hot water fixtures. The building cold water system provides make-up to the solar loop, the heating loop, and the hot water concrete storage tanks. The design, construction, cost analysis, operation and maintenance of the solar system are described. The system became operational July 11, 1979.

  15. Modeling laser damage to the retina

    Science.gov (United States)

    Clark, Clifton D.

    significantly for wavelengths in the near infrared due to an increase in the absorption coefficient for these long wavelengths. This means that less energy actually reaches the retina, but it also means that more energy is absorbed by the vitreous which can lead to significant temperature rises. The refractive index of water is known to depend on temperature, and the vitreous has very similar optical properties to water, so temperature gradients in the vitreous lead to refractive index gradients that act as a lens. Since the refractive index of water decreases with an increase in temperature, the overall effect is to establish a negative lens that defocuses a beam inside the eye during a laser exposure. This effect is a potential protection mechanism for the retina, as it would limit the time for which a laser can be sharply focused on the retina. Our model agrees well with thermal lensing measurements that have been conducted in water and we have used it to predict the retinal damage threshold as a function of exposure duration for 1318 nm exposures at various beam diameters. The model predicts that the damage threshold remains constant after some exposure time, which depends on the beam diameter. This is due mainly to the fact the retinal temperature rise is limited by the thermal lens and reaches a peak value in a relatively short time (on the order of 10 ms), which limits the amount of time that a laser exposure can cause damage. Finally, in Chapter 6 we describe the first steps we have taken in building a comprehensive short pulse retina damage model. Currently, no model capable of predicting retinal damage outcome based on the exposure parameters at the cornea exists. Models of possible damage mechanisms do exist (the damage mechanism for pulses less than about 1 mus are non-thermal), but these models assume that the exposure parameters are known at the absorption site (the retina). We have constructed a configurable, linear short pulse propagation model, that is capable

  16. Brief communication: On-site data collection of damage caused by flash floods: Experiences from Braunsbach, Germany, in May/June 2016

    Science.gov (United States)

    Laudan, Jonas; Rözer, Viktor; Sieg, Tobias; Vogel, Kristin; Thieken, Annegret

    2017-04-01

    At the end of May and beginning of June 2016, several municipalities in Southern Germany suffered from severe flash floods and debris flows which have been triggered by intense rainfall in Central Europe. Overall, the insured losses of these events amounted to EUR 1.2 billion in Germany. Especially the strong and unexpected flash flood on May 29th in Braunsbach (Baden Wurttemberg) - a small village counting about 1,000 residents - attracted media and policymakers due to its devastating character. The understanding of damage caused by flash floods requires ex-post collection of relevant but yet sparsely available information, linking process intensities to damage by using adequate methods of data gathering. Thus, on-site data collection was carried out after the flash flood event in Braunsbach, using open source software as helpful and efficient tool for data acquisition and evaluation. A digital survey was designed and conducted by a team of five researchers who investigated all buildings affected by water and debris flows. The collected data includes an estimation of a particular damage class, the inundation depth, and other relevant information. A post - hoc data analysis was done with R 3.3.1 and QGIS 2.14.3, performing both, a Random Forest Model (RF) and Random Generalized Linear Model (RGLM) as well as preparing a Spearman's rank correlation matrix. For visual interpretation and better overview of the study area and analysis results, a "process intensity" map was created, revealing important links of damage driving factors. We find that not only the water depth, which is often considered as only damage driving factor in riverine flood loss modelling, but also the exposition of a building to the flow direction and susceptible building parts like e.g. shop windows seem to be risk factors in flash-flood prone regions. Although no significant correlations were found, the analyses indicate that also building material (i.e. half-timbered or masonry) and structural

  17. Thermal analysis of building roof assisted with water heater and ...

    Indian Academy of Sciences (India)

    D Prakash

    2018-03-14

    Mar 14, 2018 ... Thermal analysis; building roof; solar water heating system; roof ... These solar collec- ... several benefits, such as its wide range of storage temper- ... rugated plate, rear plate and back insulation material [12]. ..... [7] Weiss W and Rommel M 2008 Process heat collectors. State of the art within Task 33/IV.

  18. IMPLEMENTATION OF KRIGING METHODS IN MOBILE GIS TO ESTIMATE DAMAGE TO BUILDINGS IN CRISIS SCENARIOS

    Directory of Open Access Journals (Sweden)

    S. Laun

    2016-06-01

    Full Text Available In the paper an example for the application of kriging methods to estimate damage to buildings in crisis scenarios is introduced. Furthermore, the Java implementations for Ordinary and Universal Kriging on mobile GIS are presented. As variogram models an exponential, a Gaussian and a spherical variogram are tested in detail. Different test constellations are introduced with various information densities. As test data set, public data from the analysis of the 2010 Haiti earthquake by satellite images are pre-processed and visualized in a Geographic Information System. As buildings, topography and other external influences cannot be seen as being constant for the whole area under investigation, semi variograms are calculated by consulting neighboured classified buildings using the so called moving window method. The evaluation of the methods shows that the underlying variogram model is the determining factor for the quality of the interpolation rather than the choice of the kriging method or increasing the information density of a random sample. The implementation is completely realized with the programming language Java. Thereafter, the implemented software component is integrated into GeoTech Mobile, a mobile GIS Android application based on the processing of standardized spatial data representations defined by the Open Geospatial Consortium (OGC. As a result the implemented methods can be used on mobile devices, i.e. they may be transferred to other application fields. That is why we finally point out further research with new applications in the Dubai region.

  19. Fungal colonization of fiberglass insulation in the air distribution system of a multi-story office building: VOC production and possible relationship to a sick building syndrome

    Science.gov (United States)

    Ahearn, D. G.; Crow, S. A.; Simmons, R. B.; Price, D. L.; Noble, J. A.; Mishra, S. K.; Pierson, D. L.

    1996-01-01

    Complaints characteristic of those for sick building syndrome prompted mycological investigations of a modern multi-story office building on the Gulf coast in the Southeastern United States (Houston-Galveston area). The air handling units and fiberglass duct liner of the heating, ventilating and air conditioning system of the building, without a history of catastrophic or chronic water damage, demonstrated extensive colonization with Penicillium spp and Cladosporium herbarum. Although dense fungal growth was observed on surfaces within the heating-cooling system, most air samples yielded fewer than 200 CFU m-3. Several volatile compounds found in the building air were released also from colonized fiberglass. Removal of colonized insulation from the floor receiving the majority of complaints of mouldy air and continuous operation of the units supplying this floor resulted in a reduction in the number of complaints.

  20. Stratum corneum damage and ex vivo porcine skin water absorption - a pilot study

    DEFF Research Database (Denmark)

    Duch Lynggaard, C; Bang Knudsen, D; Jemec, G B E

    2009-01-01

    A simple ex vivo screening technique would be of interest for mass screening of substances for potential barrier disruptive qualities. Ex vivo water absorption as a marker of skin barrier integrity was studied on pig ear skin. Skin water absorption was quantified by weighing and weight changes were...... found to reflect prehydration barrier damage. It is suggested that this simple model may be elaborated to provide a rapid, economical screening tool for potential skin irritants....

  1. Evaluating Post-Earthquake Building Safety Using Economical MEMS Seismometers.

    Science.gov (United States)

    Hsu, Ting-Yu; Yin, Ren-Cheng; Wu, Yih-Min

    2018-05-05

    The earthquake early warning (EEW)-research group at National Taiwan University has been developing a microelectromechanical system-based accelerometer called “P-Alert”, designed for issuing EEWs. The main advantage of P-Alert is that it is a relatively economical seismometer. However, because of the expensive nature of commercial hardware for structural health monitoring (SHM) systems, the application of SHM to buildings remains limited. To determine the performance of P-Alert for evaluating post-earthquake building safety, we conducted a series of steel-frame shaking table tests with incremental damage. We used the fragility curves of different damage levels and the interstory drift ratios (calculated by the measured acceleration of each story using double integration and a filter) to gauge the potential damage levels. We concluded that the acceptable detection of damage for an entire building is possible. With improvements to the synchronization of the P-Alert sensors, we also anticipate a damage localization feature for the stories of a building.

  2. Performance evaluation of existing building structure with pushover analysis

    Science.gov (United States)

    Handana, MAP; Karolina, R.; Steven

    2018-02-01

    In the management of the infrastructure of the building, during the period of buildings common building damage as a result of several reasons, earthquakes are common. The building is planned to work for a certain service life. But during the certain service life, the building vulnerable to damage due to various things. Any damage to cultivate can be detected as early as possible, because the damage could spread, triggering and exacerbating the latest. The newest concept to earthquake engineering is Performance Based Earthquake Engineering (PBEE). PBEE divided into two, namely Performance Based Seismic Design (PBSD) and Performance Based Seismic Evaluation (PBSE). Evaluation on PBSE one of which is the analysis of nonlinear pushover. Pushover analysis is a static analysis of nonlinear where the influence of the earthquake plan on building structure is considered as burdens static catch at the center of mass of each floor, which it was increased gradually until the loading causing the melting (plastic hinge) first within the building structure, then the load increases further changes the shapes of post-elastic large it reached the condition of elastic. Then followed melting (plastic hinge) in the location of the other structured.

  3. Economic Model Predictive Control for Hot Water Based Heating Systems in Smart Buildings

    DEFF Research Database (Denmark)

    Awadelrahman, M. A. Ahmed; Zong, Yi; Li, Hongwei

    2017-01-01

    This paper presents a study to optimize the heating energy costs in a residential building with varying electricity price signals based on an Economic Model Predictive Controller (EMPC). The investigated heating system consists of an air source heat pump (ASHP) incorporated with a hot water tank...... as active Thermal Energy Storage (TES), where two optimization problems are integrated together to optimize both the ASHP electricity consumption and the building heating consumption utilizing a heat dynamic model of the building. The results show that the proposed EMPC can save the energy cost by load...

  4. Damage-reducing measures to manage flood risks in a changing climate

    Science.gov (United States)

    Kreibich, Heidi; Bubeck, Philip; Van Vliet, Mathijs; De Moel, Hans

    2014-05-01

    Damage due to floods has increased during the last few decades, and further increases are expected in several regions due to climate change and a growing vulnerability. To address the projected increase in flood risk, a combination of structural and non-structural flood risk mitigation measures is considered as a promising adaptation strategy. Such a combination takes into account that flood defence systems may fail, and prepare for unexpected crisis situations via land-use planning, building construction, evacuation and disaster response. Non-structural flood risk mitigation measures like shielding with water shutters or sand bags, building fortification or safeguarding of hazardous substances are often voluntary: they demand self-dependent action by the population at risk (Bubeck et al. 2012; 2013). It is believed that these measures are especially effective in areas with frequent flood events and low flood water levels, but some types of measures showed a significant damage-reducing effect also during extreme flood events, such as the Elbe River flood in August 2002 in Germany (Kreibich et al. 2005; 2011). Despite the growing importance of damage-reducing measures, information is still scarce about factors that motivate people to undertake such measures, the state of implementation of various non-structural measures in different countries and their damage reducing effects. Thus, we collected information and undertook an international review about this topic in the framework of the Dutch KfC project "Climate proof flood risk management". The contribution will present an overview about the available information on damage-reducing measures and draw conclusions for practical flood risk management in a changing climate. References: Bubeck, P., Botzen, W. J. W., Suu, L. T. T., Aerts, J. C. J. H. (2012): Do flood risk perceptions provide useful insights for flood risk management? Findings from central Vietnam. Journal of Flood Risk Management, 5, 4, 295-302 Bubeck, P

  5. Public Assistance Worksheets for Damage from 2010 Floods to the East Valley Water District

    Science.gov (United States)

    East Valley Water District (EVWD) in San Bernardino, California had significant damage due to flooding in December 2010. There was a presidentially-declared disaster. EVWD applied to FEMA under the Public Assistance Grant Program.

  6. Flood impacts on a water distribution network

    Science.gov (United States)

    Arrighi, Chiara; Tarani, Fabio; Vicario, Enrico; Castelli, Fabio

    2017-12-01

    Floods cause damage to people, buildings and infrastructures. Water distribution systems are particularly exposed, since water treatment plants are often located next to the rivers. Failure of the system leads to both direct losses, for instance damage to equipment and pipework contamination, and indirect impact, since it may lead to service disruption and thus affect populations far from the event through the functional dependencies of the network. In this work, we present an analysis of direct and indirect damages on a drinking water supply system, considering the hazard of riverine flooding as well as the exposure and vulnerability of active system components. The method is based on interweaving, through a semi-automated GIS procedure, a flood model and an EPANET-based pipe network model with a pressure-driven demand approach, which is needed when modelling water distribution networks in highly off-design conditions. Impact measures are defined and estimated so as to quantify service outage and potential pipe contamination. The method is applied to the water supply system of the city of Florence, Italy, serving approximately 380 000 inhabitants. The evaluation of flood impact on the water distribution network is carried out for different events with assigned recurrence intervals. Vulnerable elements exposed to the flood are identified and analysed in order to estimate their residual functionality and to simulate failure scenarios. Results show that in the worst failure scenario (no residual functionality of the lifting station and a 500-year flood), 420 km of pipework would require disinfection with an estimated cost of EUR 21 million, which is about 0.5 % of the direct flood losses evaluated for buildings and contents. Moreover, if flood impacts on the water distribution network are considered, the population affected by the flood is up to 3 times the population directly flooded.

  7. Leaks in the internal water supply piping systems

    Directory of Open Access Journals (Sweden)

    Orlov Evgeniy Vladimirovich

    2015-03-01

    Full Text Available Great water losses in the internal plumbing of a building lead to the waste of money for a fence, purification and supply of water volumes in excess. This does not support the concept of water conservation and resource saving lying today in the basis of any building’s construction having plumbing. Leakage means unplanned of water losses systems in domestic water supply systems (hot or cold as a result of impaired integrity, complicating the operation of a system and leading to high costs of repair and equipment restoration. A large number of leaks occur in old buildings, where the regulatory service life of pipelines has come to an end, and the scheduled repair for some reason has not been conducted. Steel pipelines are used in the systems without any protection from corrosion and they get out of order. Leakages in new houses are also not uncommon. They usually occur as a result of low-quality adjustment of the system by workers. It also important to note the absence of certain skills of plumbers, who don’t conduct the inspections of in-house systems in time. Sometimes also the residents themselves forget to keep their pipeline systems and water fittings in their apartment in good condition. Plumbers are not systematically invited for preventive examinations to detect possible leaks in the domestic plumbing. The amount of unproductive losses increases while simultaneous use of valve tenants, and at the increase of the number of residents in the building. Water leaks in the system depend on the amount of water system piping damages, and damages of other elements, for example, water valves, connections, etc. The pressure in the leak area also plays an important role.

  8. Influence of spreading urbanization in flood areas on flood damage in Slovenia

    International Nuclear Information System (INIS)

    Komac, B; Zorn, M; Natek, K

    2008-01-01

    Damage caused by natural disasters in Slovenia is frequently linked to the ignoring of natural factors in spatial planning. Historically, the construction of buildings and settlements avoided dangerous flood areas, but later we see increasing construction in dangerous areas. During the floods in 1990, the most affected buildings were located on ill-considered locations, and the majority was built in more recent times. A similar situation occurred during the floods of September 2007. Comparing the effects of these floods, we determined that damage was always greater due to the urbanization of flood areas. This process furthermore increasingly limits the 'manoeuvring space' for water management authorities, who due to the torrential nature of Slovenia's rivers can not ensure the required level of safety from flooding for unsuitably located settlements and infrastructure. Every year, the Environmental Agency of the Republic of Slovenia issues more than one thousand permits for interventions in areas that affect the water regime, and through decrees the government allows construction in riparian zones, which is supposedly forbidden by the Law on Water. If we do not take measures with more suitable policies for spatial planning, we will no long have the possibility in future to reduce the negative consequences of floods. Given that torrential floods strike certain Slovene regions every three years on average and that larger floods occur at least once a decade, it is senseless to lay the blame on climate change.

  9. Solar building

    OpenAIRE

    Zhang, Luxin

    2014-01-01

    In my thesis I describe the utilization of solar energy and solar energy with building integration. In introduction it is also mentioned how the solar building works, trying to make more people understand and accept the solar building. The thesis introduces different types of solar heat collectors. I compared the difference two operation modes of solar water heating system and created examples of solar water system selection. I also introduced other solar building applications. It is conv...

  10. Building envelope

    CSIR Research Space (South Africa)

    Gibberd, Jeremy T

    2009-01-01

    Full Text Available for use in the building. This is done through photovoltaic and solar water heating panels and wind turbines. Ideally these are integrated in the design of the building envelope to improve the aesthetic quality of the building and minimise material... are naturally ventilated. Renewable energy The building envelope includes renewable energy generation such as photovoltaics, wind turbines and solar water heaters and 10% of the building’s energy requirements are generated from these sources. Views All...

  11. Evaluation of Damage to a Historic Masonry Building in Nepal through Comparison of Dynamic Characteristics before and after the 2015 Gorkha Earthquake

    Directory of Open Access Journals (Sweden)

    Aiko Furukawa

    2017-10-01

    Full Text Available On April 25, 2015, a Mw 7.8 earthquake struck the Gorkha district of Kathmandu, Nepal. In Patan, vibrational characteristics of a 300-year-old two-story masonry building near Patan Durbar Square had been measured prior the Gorkha earthquake. In the inspection of the building after the Gorkha earthquake, several new cracks were found. The vibrational characteristics of the building were measured again, and it was found that the natural frequencies after the earthquake were smaller than those before the earthquake, indicating the reduction of the stiffness. Finite element models of the structure representing pre- and post-earthquake conditions are established so that the natural frequencies match the pre- and post-earthquake measurements and the structural damage is identified based on the stiffness reduction. Finally, the dynamic analysis of the finite element model of the building in the pre-earthquake condition using the observed ground motion record during the Gorkha earthquake as the input is conducted, and the structural response of the building during the Gorkha earthquake is discussed.

  12. Changes in respiratory and non-respiratory symptoms in occupants of a large office building over a period of moisture damage remediation attempts

    Science.gov (United States)

    Cho, Sook Ja; White, Sandra K.; Cox-Ganser, Jean M.

    2018-01-01

    There is limited information on the natural history of building occupants’ health in relation to attempts to remediate moisture damage. We examined changes in respiratory and non-respiratory symptoms in 1,175 office building occupants over seven years with multiple remediation attempts. During each of four surveys, we categorized participants using a severity score: 0 = asymptomatic; 1 = mild, symptomatic in the last 12 months, but not frequently in the last 4 weeks; 2 = severe, symptomatic at least once weekly in the last 4 weeks. Building-related symptoms were defined as improving away from the building. We used random intercept models adjusted for demographics, smoking, building tenure, and microbial exposures to estimate temporal changes in the odds of building-related symptoms or severity scores independent of the effect of microbial exposures. Trend analyses of combined mild/severe symptoms showed no changes in the odds of respiratory symptoms but significant improvement in non-respiratory symptoms over time. Separate analyses showed increases in the odds of severe respiratory symptoms (odds ratio/year = 1.15‒1.16, p-valuesremediation efforts might not be effective in improving occupants’ health. PMID:29324816

  13. Comparison of computer codes relative to the aerosol behavior in the reactor containment building during severe core damage accidents in a PWR

    International Nuclear Information System (INIS)

    Fermandjian, J.; Dunbar, I.; Gauvain, J.; Ricchena, R.

    1986-02-01

    The present study concerns a comparative exercise, performed within the framework of the Commission of the European Communities, of the computer codes (AEROSISM-M, UK; AEROSOLS/BI, France; CORRAL-2, CEC and NAUA Mod5, Germany) used in order to assess the aerosol behavior in the reactor containment building during severe core damage accidents in a PWR

  14. Sustainable Urban (re-Development with Building Integrated Energy, Water and Waste Systems

    Directory of Open Access Journals (Sweden)

    Tae-Goo Lee

    2013-03-01

    Full Text Available The construction and service of urban infrastructure systems and buildings involves immense resource consumption. Cities are responsible for the largest component of global energy, water, and food consumption as well as related sewage and organic waste production. Due to ongoing global urbanization, in which the largest sector of the global population lives in cities which are already built, global level strategies need to be developed that facilitate both the sustainable construction of new cities and the re-development of existing urban environments. A very promising approach in this regard is the decentralization and building integration of environmentally sound infrastructure systems for integrated resource management. This paper discusses such new and innovative building services engineering systems, which could contribute to increased energy efficiency, resource productivity, and urban resilience. Applied research and development projects in Germany, which are based on integrated system approaches for the integrated and environmentally sound management of energy, water and organic waste, are used as examples. The findings are especially promising and can be used to stimulate further research and development, including economical aspects which are crucial for sustainable urban (re-development.

  15. Categorization of failed and damaged spent LWR [light-water reactor] fuel currently in storage

    International Nuclear Information System (INIS)

    Bailey, W.J.

    1987-11-01

    The results of a study that was jointly sponsored by the US Department of Energy and the Electric Power Research Institute are described in this report. The purpose of the study was to (1) estimate the number of failed fuel assemblies and damaged fuel assemblies (i.e., ones that have sustained mechanical or chemical damage but with fuel rod cladding that is not breached) in storage, (2) categorize those fuel assemblies, and (3) prepare this report as an authoritative, illustrated source of information on such fuel. Among the more than 45,975 spent light-water reactor fuel assemblies currently in storage in the United States, it appears that there are nearly 5000 failed or damaged fuel assemblies. 78 refs., 23 figs., 19 tabs

  16. Structural Damage in Mexico City

    OpenAIRE

    Hall, John F.; Beck, James L.

    1986-01-01

    This paper describes the structural damage in Mexico City caused by the September 19, 1985 earthquake. Photographs which illustrate various features of structural behavior are included. One explanation is presented as to why buildings with fundamental periods of elastic vibration considerably below the predominant two‐second period of the ground motion were most vulnerable to damage.

  17. Charging damage in floating metal-insulator-metal capacitors

    NARCIS (Netherlands)

    Ackaert, Jan; Wang, Zhichun; De Backer, E.; Coppens, P.

    2002-01-01

    In this paper, charging induced damage (CID) to metal-insulator-metal capacitors (MIMC) is reported. The damage is caused by the build up of a voltage potential difference between the two plates of the capacitor. A simple logarithmic relation is discovered between the damage by this voltage

  18. Towards sustainable urban water governance in Denmark: collective building of capabilities in local authorities

    DEFF Research Database (Denmark)

    Nielsen, Susanne Balslev; Jensen, Marina Bergen

    2016-01-01

    be achieved. The ‘urban water platform’ was tested and is hereby presented as a course concept for building collective capabilities for integrated sustainable water design among local authorities in Denmark. The course is an innovation because: 1) it invites urban planners, road and park managers and sewage...

  19. Aircraft-crash-protected steel reactor building roof structure for the European market

    International Nuclear Information System (INIS)

    Posta, B.A.; Kadar, I.; Rao, A.S.

    1996-01-01

    This paper recommends the use of all steel roof structures for the reactor building of European Boiling Water Reactor (BWR) plants. This change would make the advanced US BWR designs more compatible with European requirements. Replacement of the existing concrete roof slab with a sufficiently thick steel plate would eliminate the concrete spelling resulting from a postulated aircraft crash, potentially damaging the drywell head or the spent fuel pool

  20. Damage classification of pipelines under water flow operation using multi-mode actuated sensing technology

    International Nuclear Information System (INIS)

    Lee, Changgil; Park, Seunghee

    2011-01-01

    In a structure, several types of damage can occur, ranging from micro-cracking to corrosion or loose bolts. This makes identifying the damage difficult with a single mode of sensing. Therefore, a multi-mode actuated sensing system is proposed based on a self-sensing circuit using a piezoelectric sensor. In self-sensing-based multi-mode actuated sensing, one mode provides a wide frequency-band structural response from the self-sensed impedance measurement and the other mode provides a specific frequency-induced structural wavelet response from the self-sensed guided wave measurement. In this experimental study, a pipeline system under water flow operation was examined to verify the effectiveness and robustness of the proposed structural health monitoring approach. Different types of structural damage were inflicted artificially on the pipeline system. To classify the multiple types of structural damage, supervised learning-based statistical pattern recognition was implemented by composing a three-dimensional space using the damage indices extracted from the impedance and guided wave features as well as temperature variations. For a more systematic damage classification, several control parameters were optimized to determine an optimal decision boundary for the supervised learning-based pattern recognition. Further research issues are also discussed for real-world implementations of the proposed approach

  1. Plasma damage in floating metal-insulator-metal capacitors

    NARCIS (Netherlands)

    Ackaert, Jan; Wang, Zhichun; De Backer, E.; Coppens, P.

    2002-01-01

    In this paper, charging induced damage (CID) to metal-insulator-metal capacitors (MIMCs), is reported. CID does not necessarily lead to direct yield loss, but may also induce latent damage leading to reliability losses. The damage is caused by the build up of a voltage potential difference between

  2. Plasma Damage in Floating Metal-Insulator-Metal Capacitors

    NARCIS (Netherlands)

    Ackaert, Jan; Wang, Zhichun; Backer, E.; Coppens, P.

    2001-01-01

    In this paper, charging induced damage (CID) to metal-insulator-metal capacitors (MIMCs), is reported. CID does not necessarily lead to direct yield loss, but may also induce latent damage leading to reliability losses. The damage is caused by the build up of a voltage potential difference between

  3. Flood damage to historic buildings and structures

    Czech Academy of Sciences Publication Activity Database

    Drdácký, Miloš

    2010-01-01

    Roč. 24, č. 5 (2010), s. 439-445 ISSN 0887-3828 Grant - others:evropská komise(XE) FP6 Project cultural heritage protection against flood CHEF-SSPI-044251 Institutional research plan: CEZ:AV0Z20710524 Keywords : flood impact * historic structures * damage category Subject RIV: AL - Art, Architecture, Cultural Heritage Impact factor: 0.293, year: 2010

  4. Response and Damage Assessment of Reinforced Concrete Frames subject to Earthquakes

    DEFF Research Database (Denmark)

    Skjærbæk, Poul

    When civil engineering structures made of reinforced concrete (RC) such as some types of apartment buildings, hospitals, office buildings, bridges etc. are subjected to sufficiently high dynamic loads it is well known that some kind of damage will occur in the structure. The damage introduced in ...

  5. Quantitative Assessment of Water Use Efficiency in Urban and Domestic Buildings

    Directory of Open Access Journals (Sweden)

    Vicente Santiago-Fandiño

    2013-08-01

    Full Text Available This paper discusses the potential of water savings at property, household and urban levels, through the application of environmentally sound technologies (ESTs, as well as their quantification using the software Wise Water. Household centered measures are identified that allow for significant reduction of drinking water consumption with comparatively small effort, and without limitation of comfort. Furthermore, a method for the estimation of water recycling, for rainwater harvesting and for the utilization potential as locally available renewable freshwater is presented. Based on this study, the average drinking water consumption in urban households of industrialized countries could be reduced by approximately one third, without significant investment costs, either within the framework of new constructions or by the remodeling of water and sanitation systems in residential buildings. By using a secondary water quality, the drinking water demand could even be reduced by 50%. In the case of an area-wide application, the overall fresh water demand of cities and the exploitation of fresh water resources could be significantly reduced. Due to the comparability of the domestic water use of the investigated households, the findings are internationally transferable, for example to countries in Europe, Asia, and also the USA.

  6. Tsunami vulnerability and damage for buildings analyzed by means of two methods (PTVA-3 and SCHEMA) in the area of Augusta and Siracusa, eastern Sicily, Italy

    Science.gov (United States)

    Pagnoni, Gianluca; Tinti, Stefano

    2015-04-01

    The coast of the eastern Sicily is exposed to tsunamis that can be generated by local earthquakes (e.g. the 1169, 1693, 1908 events) and by earthquakes located in distant seismic zones (see the 365 AD tsunamigenic quake in Western Hellenic Arc). Tsunamis can also be generated by landslides possibly triggered by earthquakes. The Hyblean-Malta steep escarpment running offshore at a small angle with the coast is an ideal place for submarine mass failure occurrences with tsunamigenic effects. The entire eastern coast of Sicily from Messina in the north to Siracusa in the south is under the threat of tsunamis. In the frame of the FP7 European project ASTARTE (Assessment, Strategy And Risk Reduction for Tsunamis in Europe - FP7-ENV2013 6.4-3, Grant 603839), the segment of coast from Augusta to Siracusa was selected to undertake specific and detailed studies of tsunami hazard, vulnerability and damage to test existing methods and develop innovative approaches. The scope of the present work regards vulnerability and damage analyses. We chose to adopt two methods, known in the literature and briefly denoted as PTVA-3 and SCHEMA, that are based on two very different approaches, the former more qualitative and the latter more quantitative. The method PTVA-3 determines the vulnerability and damageability of a building by weighting and ranking a number of attributes covering the structural features of the edifice and the relevant characteristics of the surrounding environment such as the position with respect to the coast, the existence of defensive elements (e.g. walls, breakwaters, vegetation) and also the proximity to potential sources of floating objects that can feed damaging debris flows. On the other hand, the SCHEMA method uses a classification of building and a damage matrix that were derived from experimental fragility and damage curves first established after the Sumatra 2004 tsunami and later refined and adapted to the building stock of the Mediterranean region. The

  7. Earthquake risk assessment of building structures

    International Nuclear Information System (INIS)

    Ellingwood, Bruce R.

    2001-01-01

    During the past two decades, probabilistic risk analysis tools have been applied to assess the performance of new and existing building structural systems. Structural design and evaluation of buildings and other facilities with regard to their ability to withstand the effects of earthquakes requires special considerations that are not normally a part of such evaluations for other occupancy, service and environmental loads. This paper reviews some of these special considerations, specifically as they pertain to probability-based codified design and reliability-based condition assessment of existing buildings. Difficulties experienced in implementing probability-based limit states design criteria for earthquake are summarized. Comparisons of predicted and observed building damage highlight the limitations of using current deterministic approaches for post-earthquake building condition assessment. The importance of inherent randomness and modeling uncertainty in forecasting building performance is examined through a building fragility assessment of a steel frame with welded connections that was damaged during the Northridge Earthquake of 1994. The prospects for future improvements in earthquake-resistant design procedures based on a more rational probability-based treatment of uncertainty are examined

  8. Building Adjustable Pre-storm Reservoir Flood-control Release Rules

    Science.gov (United States)

    Yang, Shun-Nien; Chang, Li-Chiu; Chang, Fi-John; Hsieh, Cheng-Daw

    2017-04-01

    Typhoons hit Taiwan several times every year, which could cause serious flood disasters. Because mountainous terrains and steep landforms can rapidly accelerate the speed of flood flow during typhoon events, rivers cannot be a stable source of water supply. Reservoirs become the most effective floodwater storage facilities for alleviating flood damages in Taiwan. The pre-storm flood-control release can significantly increase reservoir storage capacity available to store floodwaters for reducing downstream flood damage, while the uncertainties of total forecasted rainfalls are very high in different stages of an oncoming typhoon, which may cause the risk of water shortage in the future. This study proposes adjustable pre-storm reservoir flood-control release rules in three designed operating stages with various hydrological conditions in the Feitsui Reservoir, a pivot reservoir for water supply to Taipei metropolitan in Taiwan, not only to reduce the risk of reservoir flood control and downstream flooding but also to consider water supply. The three operating stages before an oncoming typhoon are defined upon the timings when: (1) typhoon news is issued (3-7days before typhoon hit); (2) the sea warning is issued (2-4 days before typhoon hit); and (3) the land warning is issued (1-2 days before typhoon hit). We simulate 95 historical typhoon events with 3000 initial water levels and build some pre-storm flood-control release rules to adjust the amount of pre-release based on the total forecasted rainfalls at different operating stages. A great number of simulations (68.4 millions) are conducted to extract their major consequences and then build the adjustable pre-storm reservoir flood-control release rules. Accordingly, given a total forecasted rainfall and a water level, reservoir decision makers can easily identify the corresponding rule to tell the amount of pre-release in any stage. The results show that the proposed adjustable pre-release rules can effectively

  9. Oblique Aerial Photography Tool for Building Inspection and Damage Assessment

    Science.gov (United States)

    Murtiyoso, A.; Remondino, F.; Rupnik, E.; Nex, F.; Grussenmeyer, P.

    2014-11-01

    Aerial photography has a long history of being employed for mapping purposes due to some of its main advantages, including large area imaging from above and minimization of field work. Since few years multi-camera aerial systems are becoming a practical sensor technology across a growing geospatial market, as complementary to the traditional vertical views. Multi-camera aerial systems capture not only the conventional nadir views, but also tilted images at the same time. In this paper, a particular use of such imagery in the field of building inspection as well as disaster assessment is addressed. The main idea is to inspect a building from four cardinal directions by using monoplotting functionalities. The developed application allows to measure building height and distances and to digitize man-made structures, creating 3D surfaces and building models. The realized GUI is capable of identifying a building from several oblique points of views, as well as calculates the approximate height of buildings, ground distances and basic vectorization. The geometric accuracy of the results remains a function of several parameters, namely image resolution, quality of available parameters (DEM, calibration and orientation values), user expertise and measuring capability.

  10. Structural damages of L'Aquila (Italy earthquake

    Directory of Open Access Journals (Sweden)

    H. Kaplan

    2010-03-01

    Full Text Available On 6 April 2009 an earthquake of magnitude 6.3 occurred in L'Aquila city, Italy. In the city center and surrounding villages many masonry and reinforced concrete (RC buildings were heavily damaged or collapsed. After the earthquake, the inspection carried out in the region provided relevant results concerning the quality of the materials, method of construction and the performance of the structures. The region was initially inhabited in the 13th century and has many historic structures. The main structural materials are unreinforced masonry (URM composed of rubble stone, brick, and hollow clay tile. Masonry units suffered the worst damage. Wood flooring systems and corrugated steel roofs are common in URM buildings. Moreover, unconfined gable walls, excessive wall thicknesses without connection with each other are among the most common deficiencies of poorly constructed masonry structures. These walls caused an increase in earthquake loads. The quality of the materials and the construction were not in accordance with the standards. On the other hand, several modern, non-ductile concrete frame buildings have collapsed. Poor concrete quality and poor reinforcement detailing caused damage in reinforced concrete structures. Furthermore, many structural deficiencies such as non-ductile detailing, strong beams-weak columns and were commonly observed. In this paper, reasons why the buildings were damaged in the 6 April 2009 earthquake in L'Aquila, Italy are given. Some suggestions are made to prevent such disasters in the future.

  11. 75 FR 78231 - Management of Energy and Water Efficiency in Federal Buildings: Availability of Guidance

    Science.gov (United States)

    2010-12-15

    ... Water Efficiency in Federal Buildings: Availability of Guidance AGENCY: Office of Energy Efficiency and Renewable Energy, Department of Energy. ACTION: Notice of availability. SUMMARY: This notice of availability... regarding Federal agency implementation of energy and water efficiency requirements. The draft Guidance for...

  12. Wood-destroying Coleopteran species in the historical buildings in ...

    African Journals Online (AJOL)

    The aim of this study is to identify the harmful insects causing damage in the historical wooden buildings of Kastamonu. Accordingly, 15 of those historical wooden buildings situated in the city were periodically controlled between the years 2002 and 2005. During those periodic controls, damages caused by insects were ...

  13. Short-Lived Buildings in China: Impacts on Water, Energy, and Carbon Emissions.

    Science.gov (United States)

    Cai, Wenjia; Wan, Liyang; Jiang, Yongkai; Wang, Can; Lin, Lishen

    2015-12-15

    This paper has changed the vague understanding that "the short-lived buildings have huge environmental footprints (EF)" into a concrete one. By estimating the annual floor space of buildings demolished and calibrating the average building lifetime in China, this paper compared the EF under various assumptive extended buildings' lifetime scenarios based on time-series environmental-extended input-output model. Results show that if the average buildings' lifetime in China can be extended from the current 23.2 years to their designed life expectancy, 50 years, in 2011, China can reduce 5.8 Gt of water withdrawal, 127.1 Mtce of energy consumption, and 426.0 Mt of carbon emissions, each of which is equivalent to the corresponding annual EF of Belgium, Mexico, and Italy. These findings will urge China to extend the lifetime of existing and new buildings, in order to reduce the EF from further urbanization. This paper also verifies that the lifetime of a product or the replacement rate of a sector is a very important factor that influences the cumulative EF. When making policies to reduce the EF, adjusting people's behaviors to extend the lifetime of products or reduce the replacement rate of sectors may be a very simple and cost-effective option.

  14. Performance-based methodology for assessing seismic vulnerability and capacity of buildings

    Science.gov (United States)

    Shibin, Lin; Lili, Xie; Maosheng, Gong; Ming, Li

    2010-06-01

    This paper presents a performance-based methodology for the assessment of seismic vulnerability and capacity of buildings. The vulnerability assessment methodology is based on the HAZUS methodology and the improved capacitydemand-diagram method. The spectral displacement ( S d ) of performance points on a capacity curve is used to estimate the damage level of a building. The relationship between S d and peak ground acceleration (PGA) is established, and then a new vulnerability function is expressed in terms of PGA. Furthermore, the expected value of the seismic capacity index (SCev) is provided to estimate the seismic capacity of buildings based on the probability distribution of damage levels and the corresponding seismic capacity index. The results indicate that the proposed vulnerability methodology is able to assess seismic damage of a large number of building stock directly and quickly following an earthquake. The SCev provides an effective index to measure the seismic capacity of buildings and illustrate the relationship between the seismic capacity of buildings and seismic action. The estimated result is compared with damage surveys of the cities of Dujiangyan and Jiangyou in the M8.0 Wenchuan earthquake, revealing that the methodology is acceptable for seismic risk assessment and decision making. The primary reasons for discrepancies between the estimated results and the damage surveys are discussed.

  15. GIS UTILITY FOR HYDROLOGICAL IMPACT EVALUATION CAUSED BY DAMAGES OF WATER SUPPLY NETWORK IN RURAL AREAS. APPLICATIONS IN BAIA MARE DEPRESSION

    Directory of Open Access Journals (Sweden)

    RADU ALEXANDRU MARIAN

    2012-11-01

    Full Text Available GIS utility for hydrological impact evaluation caused by damages of water supply network in rural areas. Applications in Baia Mare Depression. Occurrence of a failure within the water supply network is an element of risk with important hydrological implications. Although at first glance you might think that a pipe diameter of only 20 cm can generate large effects, however, in case of significant damage or even burst pipe, a good part of high water flow in the pipe (approx. 25 m3/h on average in the Baia Mare associated with a long duration of failure (several hours may be in the drain area, impact on the local community. Regarding rural settlements, surface drainage allow a quantity of water retention tank underground infiltration but in many cases lack of a sewage system effectively contribute to increased negative consequences related to such damage (flooding farms, roads, crops compromise of flooding or drought in the event of damage to the hot water supply pipe and so on. This paper focuses on the role of Geographic Information Systems (GIS to assess the impact of runoff induced by damages in rural areas. The study therefore spatial aspect, through GIS, on the one hand runoff along the flow path with the start point of the network fault location and view previous hydrological conditions of the terrain, and on the other hand the impact of runoff the rural community. Study area Dumbrăviţa settlement located in Baia Mare Depression. This village is part of water supply system to the south and southeast of Baia Mare.

  16. Diurnal variations in depth profiles of UV-induced DNA damage and inhibition of bacterioplankton production in tropical coastal waters

    NARCIS (Netherlands)

    Visser, PM; Poos, JJ; Scheper, BB; Boelen, P; van Duyl, FC

    2002-01-01

    In this study, diurnal changes in bacterial production and DNA damage in bacterio-plankton (measured as cyclobutane pyrimidine dimers, CPDs) incubated in bags at different depths in tropical coastal waters were investigated. The DNA damage and inhibition of the bacterial production was highest at

  17. What if quality of damage data is poor: an Entity-Vulnerability approach for flood vulnerability assessment

    Science.gov (United States)

    Naso, Susanna; Chen, Albert S.; Djordjević, Slobodan; Aronica, Giuseppe T.

    2015-04-01

    The classical approach to flood defence, aimed at reducing the probability of flooding through hard defences, has been substituted by flood risk management approach which accepts the idea of coping with floods and aims at reducing not only the probability of flooding, but also the consequences. In this view, the concept of vulnerability becomes central, such as the (non-structural) measures for its increment. On 22 November 2011, an exceptional rainstorm hit the Longano catchment (North-East part of Sicily, Italy) producing local heavy rainfall, mud-debris flow and flash flooding. The flash flood involved property, buildings, roads and more than 100 commercial estates have suffered severe damages. Some days after the event, the municipality provided people forms to describe the damages that occurred on their properties. Unfortunately, the lack of common guidelines in compiling them, their coarseness and the impossibility to have monetary information on them (such us damage data from previous events), did not allow the implementation of a detailed damage analysis. What we're developing in this work is a method for a qualitative evaluation of the consequences of floods, based on vulnerability curves for structures and classes of entities at risk. The difficulty in deriving the vulnerability curves for different building typologies, as function of the water depth, was due to the lack of quantitative information both on damages caused by previous events and on buildings' value. To solve the problem we submitted a questionnaire to a team of experts asking for an estimation of building damages to different hypothetical inundation depths. What we wanted to obtain was deriving the vulnerability data from technicians' experience, believing in the fundamental importance of the collaboration among research and professional engineers. Through the elaboration and the synthesis of the experts' estimations we derived the vulnerability curves for different building typologies and

  18. Rockfall vulnerability assessment for reinforced concrete buildings

    Science.gov (United States)

    Mavrouli, O.; Corominas, J.

    2010-10-01

    The vulnerability of buildings to the impact of rockfalls is a topic that has recently attracted increasing attention in the scientific literature. The quantification of the vulnerability, when based on empirical or heuristic approaches requires data recorded from historical rockfalls, which are not always available. This is the reason why appropriate alternatives are required. The use of analytical and numerical models can be one of them. In this paper, a methodology is proposed for the analytical evaluation of the vulnerability of reinforced concrete buildings. The vulnerability is included in the risk equation by incorporating the uncertainty of the impact location of the rock block and the subsequent damage level. The output is a weighted vulnerability that ranges from 0 to 1 and expresses the potential damage that a rock block causes to a building in function of its velocity and size. The vulnerability is calculated by the sum of the products of the probability of block impact on each element of the building and its associated damage state, the latter expressed in relative recovery cost terms. The probability of exceeding a specific damage state such as non-structural, local, partial, extensive or total collapse is also important for the quantification of risk and to this purpose, several sets of fragility curves for various rock diameters and increasing velocities have been prepared. An example is shown for the case of a simple reinforced concrete building and impact energies from 0 to 4075 kJ.

  19. Evaluation and planning for lightning rod grounding of PSTA cyclotron building

    International Nuclear Information System (INIS)

    Suyamto; Taufik; Idrus Abdul Kudus

    2015-01-01

    Lightning rod connected with the ground resistance is an equipment protection against hazards of lightning strikes building. Lightning strike to the building may result in damage to the building and destroy all the equipment inside it. The need for a lightning rod of a building is regulated in PUIPP expressed with risk factors (FR). The amount of FR is the sum of the value of the index of five (5 ) components of the building i.e building functions, construction, the height and the situation of the building and and the number of yearly lightning days in that places. At this time 05 PSTA building has undergone changes in the function of the building's mechanical workshop into a cyclotron building so that safety criteria also change into vital building with lightning rods resistance have to < 1 Ω. From measurements of grounding resistant which exist at present known that average Rp is 1.26 Ω so it is necessary to install new additional grounding resistance to reduce being less than 1 Ω. To fulfil this and taking into consideration the cost and ease of installation, planned addition of a grounding using electrodes solid rods of copper, a diameter of 16 mm and a length of 4 m , planted the soil water depth of 12 m, as well as clay covering, with a water content of about 30 %. Under these conditions and taking into the cost and ease of installation are expected to obtain optimal results i.e. soil resistivity 18.35 Ω-m and its resistance of Rx 4.82 Ω. When coupled with existing grounding final resistant Rp 0.99 Ω obtained is thus fulfilling the requirements of PUIPP that is less than 1 Ω. (author)

  20. Damage caused to houses and equipment by underground nuclear explosions

    International Nuclear Information System (INIS)

    Delort, F.; Guerrini, C.

    1969-01-01

    A description is given of the damaged caused to various structures, buildings, houses, mechanical equipment and electrical equipment by underground nuclear explosions in granite. For each type of equipment or building are given the limiting distances for a given degree of damage. These distances have been related to a parameter characterizing the movement of the medium; it is thus possible to generalize the results obtained in granite, for different media. The problem of estimating the damage caused at a greater distance from the explosion is considered. (authors) [fr

  1. Demand side management for commercial buildings using an in line heat pump water heating methodology

    International Nuclear Information System (INIS)

    Rankin, Riaan; Rousseau, Pieter G.; Eldik, Martin van

    2004-01-01

    Most of the sanitary hot water used in South African buildings is heated by means of direct electrical resistance heaters. This is one of the major contributors to the undesirably high morning and afternoon peaks imposed on the national electricity supply grid. For this reason, water heating continues to be of concern to the electricity supplier, ESCOM. Previous studies, conducted by the Potchefstroom University for Christian Higher Education in South Africa, indicated that extensive application of the so called inline heat pump water heating methodology in commercial buildings could result in significant demand side management savings to ESKOM. Furthermore, impressive paybacks can be obtained by building owners who choose to implement the design methodology on existing or new systems. Currently, a few examples exist where the design methodology has been successfully implemented. These installations are monitored with a fully web centric monitoring system that allows 24 h access to data from each installation. Based on these preliminary results, a total peak demand reduction of 108 MW can be achieved, which represents 18% of the peak load reduction target set by ESKOM until the year 2015. This represents an avoided cost of approximately MR324 (ZAR) [Int J Energy Res 25(4) (1999) 2000]. Results based on actual data from the monitored installations shows a significant peak demand reduction for each installation. In one installation, a hotel with an occupancy of 220 people, the peak demand contribution of the hot water installation was reduced by 86%, realizing a 36% reduction in peak demand for the whole building. The savings incurred by the building owner also included significant energy consumption savings due to the superior energy efficiency of the heat pump water heater. The combined savings result in a conservatively calculated straight payback period of 12.5 months, with an internal rate of return of 98%. The actual cost of water heating is studied by

  2. Measured moisture in buildings and adverse health effects: a review.

    Science.gov (United States)

    Mendell, Mark J; Macher, Janet M; Kumagai, Kazukiyo

    2018-04-23

    It has not yet been possible to quantify dose-related health risks attributable to indoor dampness or mold (D/M), to support the setting of health-related limits for D/M. An overlooked target for assessing D/M is moisture in building materials, the critical factor allowing microbial growth. A search for studies of quantified building moisture and occupant health effects identified three eligible studies. Two studies assessed associations between measured wall moisture content and respiratory health in the UK. Both reported dose-related increases in asthma exacerbation with higher measured moisture, with one study reporting an adjusted odds ratio (OR) of 7.0 for night-time asthma symptoms with higher bedroom moisture. The third study assessed relationships between infrared camera-determined wall moisture and atopic dermatitis in South Korea, reporting an adjusted OR of 14.5 for water-damaged homes and moderate or severe atopic dermatitis. Measuring building moisture has, despite extremely limited available findings, potential promise for detecting unhealthy D/M in homes and merits more research attention. Further research to validate these findings should include measured "water activity," which directly assesses moisture availability for microbial growth. Ultimately, evidence-based, health-related thresholds for building moisture, across specific materials and measurement devices, could better guide assessment and remediation of D/M in buildings. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  3. The occurrence of legionalla in hot water distribution systems of some Finnish apartment and office buildings

    Energy Technology Data Exchange (ETDEWEB)

    Zacheus, O M; Kuittinen, M H; Martikainen, P J [National Public Health Institute, Dept. Environ. Hyg. and Toxicol., Kuopio (FI)

    1991-01-01

    A project concerning the effect of water temperature and water quality on the microbiology of hot water distribution systems in Finnish apartment and office buildings was started in 1989. Here we report preliminary results on the occurrence of legionella. Samples were taken from showerpipes and from hot water mains before and after calorifiers of 17 buildings. Water temperature in the showerpipes ranged from 39 to 55 deg. C. Water temperature before calorifiers ranged from 40 to 52 deg. C and after them from 39 to 59 deg. C. Water temperature did not explain well the occurrence of legionalla. Legionalla pneumophila was isolated from six systems. The isolates were serogroups 1, 5 and 6. Legionella concentrations in positive samples ranged from 100 to 350 000 CFU/l. Highest concentrations of legionalla were obtained from showerpipes and hot water mains before calorifiers. Four legionella positive distribution systems were decontaminated by raising the water temperature to 60-70 deg. C and cleaning taps and showerheads, and flushing them twice a day. The numbers of legionellas in the hot water mains fell below detection limit (50 CFU/l) and their numbers also decreased in showerpipes. Decontamination failed in some parts of the distribution systems where water temperature remained below 60 deg. C. (author) 26 refs.

  4. Study on vulnerability matrices of masonry buildings of mainland China

    Science.gov (United States)

    Sun, Baitao; Zhang, Guixin

    2018-04-01

    The degree and distribution of damage to buildings subjected to earthquakes is a concern of the Chinese Government and the public. Seismic damage data indicates that seismic capacities of different types of building structures in various regions throughout mainland China are different. Furthermore, the seismic capacities of the same type of structure in different regions may vary. The contributions of this research are summarized as follows: 1) Vulnerability matrices and earthquake damage matrices of masonry structures in mainland China were chosen as research samples. The aim was to analyze the differences in seismic capacities of sample matrices and to present general rules for categorizing seismic resistance. 2) Curves relating the percentage of damaged masonry structures with different seismic resistances subjected to seismic demand in different regions of seismic intensity (VI to X) have been developed. 3) A method has been proposed to build vulnerability matrices of masonry structures. The damage ratio for masonry structures under high-intensity events such as the Ms 6.1 Panzhihua earthquake in Sichuan province on 30 August 2008, was calculated to verify the applicability of this method. This research offers a significant theoretical basis for predicting seismic damage and direct loss assessment of groups of buildings, as well as for earthquake disaster insurance.

  5. Finding the displacement of wood structure in heritage building by 3D laser scanner

    Science.gov (United States)

    Lee, M. C.; Tsai, Y. L.; Wang, R. Z.; Lin, M. L.

    2015-08-01

    Heritage buildings are highly prone to long term damage from the microclimate, scourge and vandalism, which can result in damaged materials, structures, painting and cultural heritage items. This study will focus on finding the displacement of wood structural members through the use of a 3D laser scanner and the 4D concept of time. The results will compare the scans from different periods to find the difference (if any) in the structural member position. Wood structures usually consist of numerous wood members connected to form the structure. However, these members can be damaged in various ways such as physical mechanisms, chemical reactions, and biological corrosion. When damage to the wood structure occurs, the structural displacement can be affected, and if affected severely, can lead to a building collapse. Monitoring of the structural displacement is the best way to discover damage immediately and to preserve the heritage building. However, the Cultural Heritage Preservation Law in Taiwan prohibits the installation of monitoring instruments (e.g strain gauge, accelerometer) in historic structures (heritage buildings). Scanning the wood structure with 3D lasers is the most non-intrusive method and quickly achieves displacement through visualization. The displacement scan results can be compared with different periods and different members to analyze the severity of damage. Once the 3D scanner is installed, the whole building is scanned, and point clouds created to build the visual building model. The structural displacement can be checked via the building model and the differences are measured between each member to find the high risk damaged areas or members with large displacement. Early detection of structural damage is the most effective way means of preservation.

  6. Rational designing of the internal water supply system in reconstructed residential buildings of mass standard series

    OpenAIRE

    Orlov Evgeny

    2018-01-01

    The issues of water supply system reconstruction in mass series buildings are reviewed with consideration of water- and resource saving. Principal points for location of plumbing cells in apartments, arrangement of water devices and wastewater receivers, selection of pipelines for reconstructed water line are described. Comparative analysis of design variants of inner water line before and following reconstruction are given. It was found that applying the developed system design approaches th...

  7. Serviceability criteria for buildings in mine subsidence area -- Adjustment to Eurocodes

    International Nuclear Information System (INIS)

    Kawulok, M.; Sulimowski, Z.

    1994-01-01

    Due to ground deformations caused by underground mining, building structures in mining areas are frequently subjected to considerable deformations and damage to the finishing and structural elements. As a consequence, serviceable values of such structures are distinctly diminished, and in extreme cases, seriously damaged structures may be exempted from further service. These problems are not duly represented in the existing building standard codes. It is also important to determine relationship between damage stage and value of the building, and hence the strategy for reconstruction or renovation works. The paper presents proposals concerning serviceability criteria of building structures in mining areas, in terms of basic standard requirements valid in building in Poland, as well as proposals of Eurocodes. Building structures under consideration have been divided into structures designed to resist mining influences and existing structures, not adapted to conform to these influences at the design and erection stages

  8. SCDAP: a light water reactor computer code for severe core damage analysis

    International Nuclear Information System (INIS)

    Marino, G.P.; Allison, C.M.; Majumdar, D.

    1982-01-01

    Development of the first code version (MODO) of the Severe Core Damage Analysis Package (SCDAP) computer code is described, and calculations made with SCDAP/MODO are presented. The objective of this computer code development program is to develop a capability for analyzing severe disruption of a light water reactor core, including fuel and cladding liquefaction, flow, and freezing; fission product release; hydrogen generation; quenched-induced fragmentation; coolability of the resulting geometry; and ultimately vessel failure due to vessel-melt interaction. SCDAP will be used to identify the phenomena which control core behavior during a severe accident, to help quantify uncertainties in risk assessment analysis, and to support planning and evaluation of severe fuel damage experiments and data. SCDAP/MODO addresses the behavior of a single fuel bundle. Future versions will be developed with capabilities for core-wide and vessel-melt interaction analysis

  9. Possibility of heat recovery from gray water in residential building

    Directory of Open Access Journals (Sweden)

    Mazur Aleksandra

    2017-12-01

    Full Text Available Recovery of waste heat from gray water can be an interesting alternative to other energy saving systems in a building, including alternative energy sources. Mainly, due to a number of advantages including independence from weather conditions, small investment outlay, lack of user support, or a slight interference with the installation system. The purpose of this article is to present the financial effectiveness of installations which provide hot, usable water to a detached house, using a Drain Water Heat Recovery (DWHR system depending on the number of system users and the various combinations of bathing time in the shower, which has an influence on the daily warm water demand in each of the considered options. The economic analysis of the adopted installation variants is based on the Life Cycle Cost (LCC method, which is characterized by the fact that it also includes the operating costs in addition to the capital expenditure during the entire analysis period. For each case, the necessary devices were selected and the cost of their installation was estimated.

  10. Possibility of heat recovery from gray water in residential building

    Science.gov (United States)

    Mazur, Aleksandra; Słyś, Daniel

    2017-12-01

    Recovery of waste heat from gray water can be an interesting alternative to other energy saving systems in a building, including alternative energy sources. Mainly, due to a number of advantages including independence from weather conditions, small investment outlay, lack of user support, or a slight interference with the installation system. The purpose of this article is to present the financial effectiveness of installations which provide hot, usable water to a detached house, using a Drain Water Heat Recovery (DWHR) system depending on the number of system users and the various combinations of bathing time in the shower, which has an influence on the daily warm water demand in each of the considered options. The economic analysis of the adopted installation variants is based on the Life Cycle Cost (LCC) method, which is characterized by the fact that it also includes the operating costs in addition to the capital expenditure during the entire analysis period. For each case, the necessary devices were selected and the cost of their installation was estimated.

  11. Novel high-fidelity realistic explosion damage simulation for urban environments

    Science.gov (United States)

    Liu, Xiaoqing; Yadegar, Jacob; Zhu, Youding; Raju, Chaitanya; Bhagavathula, Jaya

    2010-04-01

    Realistic building damage simulation has a significant impact in modern modeling and simulation systems especially in diverse panoply of military and civil applications where these simulation systems are widely used for personnel training, critical mission planning, disaster management, etc. Realistic building damage simulation should incorporate accurate physics-based explosion models, rubble generation, rubble flyout, and interactions between flying rubble and their surrounding entities. However, none of the existing building damage simulation systems sufficiently faithfully realize the criteria of realism required for effective military applications. In this paper, we present a novel physics-based high-fidelity and runtime efficient explosion simulation system to realistically simulate destruction to buildings. In the proposed system, a family of novel blast models is applied to accurately and realistically simulate explosions based on static and/or dynamic detonation conditions. The system also takes account of rubble pile formation and applies a generic and scalable multi-component based object representation to describe scene entities and highly scalable agent-subsumption architecture and scheduler to schedule clusters of sequential and parallel events. The proposed system utilizes a highly efficient and scalable tetrahedral decomposition approach to realistically simulate rubble formation. Experimental results demonstrate that the proposed system has the capability to realistically simulate rubble generation, rubble flyout and their primary and secondary impacts on surrounding objects including buildings, constructions, vehicles and pedestrians in clusters of sequential and parallel damage events.

  12. Damage Detection and Deteriorating Structural Systems

    DEFF Research Database (Denmark)

    Long, Lijia; Thöns, Sebastian; Döhler, Michael

    2017-01-01

    This paper addresses the quantification of the value of damage detection system and algorithm information on the basis of Value of Information (VoI) analysis to enhance the benefit of damage detection information by providing the basis for its optimization before it is performed and implemented....... The approach of the quantification the value of damage detection information builds upon the Bayesian decision theory facilitating the utilization of damage detection performance models, which describe the information and its precision on structural system level, facilitating actions to ensure the structural...... detection information is determined utilizing Bayesian updating. The damage detection performance is described with the probability of indication for different component and system damage states taking into account type 1 and type 2 errors. The value of damage detection information is then calculated...

  13. Damage of reactor buildings occurred at the Fukushima Daiichi accident. Focusing on sequence leading to hydrogen explosions

    International Nuclear Information System (INIS)

    Naito, Masanori

    2011-01-01

    Fukushima Daiichi accident discharged enormous radioactive materials confined inside into the environment due to hydrogen explosions occurred at reactor buildings and forced many people to live the refugee life. This article described overview of Great East Japan Earthquake, specifications of Fukushima Daiichi nuclear power plants, sequence of plant status after earthquake occurrence and computerized simulation of plant behavior of Unit 1 leading to core melt and hydrogen explosion. Simulation results with estimated and assumed conditions showed water level decreased to bottom of reactor core after 4 hrs and 15 minutes passed, core melt started after 6 hrs and 49 minutes passed, failure of core support plate after 7 hrs and 18 minutes passed and through failure of penetration at bottom of pressure vessel after 7 hrs and 25 minutes passed. Hydrogen concentration at operating floor of reactor building of Unit 1 would be 15% accumulated and the pressure would amount to about 5 bars after hydrogen explosion if reactor building did not rupture with leak-tight structure. Since reactor building was not pressure-proof structure, walls of operating floor would rupture before 5 bars attained. (T. Tanaka)

  14. NIPGAT: new tool for investigating the deterioration of monuments and historic buildings

    International Nuclear Information System (INIS)

    Jaafar Abdullah; Lahasen Norman Shah Dahing; Susan Maria Sipaun; Md Fakaruddin Abdul Rahman; Ismail Mustapha

    2004-01-01

    The degradation of some building materials such as brick and mortar is a major problem for the preservation of monuments or historic structures, especially where it is desirable to preserve the original fabric of the building. Such degradation often arises from the presence of contaminants in the constituent materials. Knowledge of the presence and distribution of contaminants is needed for effective treatment and preservation. In building materials, water and soluble salt are considered two unwanted contaminants. Their concentrations and distribution in these materials are very important factor in estimating the degree of building deterioration. Water is a major course of deterioration, both by acting as a solvent for various building materials components and by exerting stresses on the structure during thermal cycle. The soluble salts, notably chlorides, damage the structure either by periodically dissolving and recrystallising within the pores or by promoting corrosion. Neutrons are useful as probes for non-destructive examination of extended media because neutrons can travel relatively long distances before interacting with the nuclei of the media. Depending on the type of material, neutrons can have a mean free path of tens of centimeters to meters. It is for this reason that neutrons in conjunction with gamma-ray spectroscopy have been used extensively in oil-well logging and mineral exploration. For the same reason, a new method, called neutron-induced prompt gamma-ray technique, NIPGAT is being developed at MINT for preservation of monuments and historic buildings. NIPGAT can be used for in-situ quantitative determination and location of contaminants, particularly water and soluble salt in building materials. This paper presents a brief overview and gives preliminary results of NIPGAT research activities at MINT. It is hoped that it may raise awareness and promote further opportunities for the collaboration of the nuclear research scientists with the museum

  15. Reconstruction of War Damaged Buildings - A Problem that Still Stands. The Case of the National Economy Bank in Warsaw Restored During the Second World War

    Science.gov (United States)

    Łotysz, Sławomir

    2016-12-01

    The Polish national historiography remains silent on the reconstruction of damaged towns and cities that was undertaken by the German administration after capturing Poland in September 1939. This paper, on the war-time restoration of the National Economy Bank's headquarters in Warsaw, is an attempt to at least partially fill the gap. Designed by celebrated architect Rudolf Świerczyński in the late 1920s in accordance with contemporary air raid defence regulations, it was bombed and nevertheless seriously damaged during the September Campaign. Under the German management of the bank, the building was reconstructed and even modernized by commissioned Polish engineers.

  16. POTENTIAL OF MULTI-TEMPORAL OBLIQUE AIRBORNE IMAGERY FOR STRUCTURAL DAMAGE ASSESSMENT

    Directory of Open Access Journals (Sweden)

    A. Vetrivel

    2016-06-01

    Full Text Available Quick post-disaster actions demand automated, rapid and detailed building damage assessment. Among the available technologies, post-event oblique airborne images have already shown their potential for this task. However, existing methods usually compensate the lack of pre-event information with aprioristic assumptions of building shapes and textures that can lead to uncertainties and misdetections. However, oblique images have been already captured over many cities of the world, and the exploitation of pre- and post-event data as inputs to damage assessment is readily feasible in urban areas. In this paper, we investigate the potential of multi-temporal oblique imagery for detailed damage assessment focusing on two methodologies: the first method aims at detecting severe structural damages related to geometrical deformation by combining the complementary information provided by photogrammetric point clouds and oblique images. The developed method detected 87% of damaged elements. The failed detections are due to varying noise levels within the point cloud which hindered the recognition of some structural elements. We observed, in general that the façade regions are very noisy in point clouds. To address this, we propose our second method which aims to detect damages to building façades using the oriented oblique images. The results show that the proposed methodology can effectively differentiate among the three proposed categories: collapsed/highly damaged, lower levels of damage and undamaged buildings, using a computationally light-weight approach. We describe the implementations of the above mentioned methods in detail and present the promising results achieved using multi-temporal oblique imagery over the city of L’Aquila (Italy.

  17. Radiation Damage in Scintillating Crystals

    CERN Document Server

    Zhu Ren Yuan

    1998-01-01

    Crystal Calorimetry in future high energy physics experiments faces a new challenge to maintain its precision in a hostile radiation environment. This paper discusses the effects of radiation damage in scintillating crystals, and concludes that the predominant radiation damage effect in crystal scintillators is the radiation induced absorption, or color center formation, not the loss of the scintillation light yield. The importance of maintaining crystal's light response uniformity and the feasibility to build a precision crystal calorimeter under radiation are elaborated. The mechanism of the radiation damage in scintillating crystals is also discussed. While the damage in alkali halides is found to be caused by the oxygen or hydroxyl contamination, it is the structure defects, such as oxygen vacancies, cause damage in oxides. Material analysis methods used to reach these conclusions are presented in details.

  18. Maintenance Planning for Historic Buildings

    Directory of Open Access Journals (Sweden)

    Diana Plian

    2008-01-01

    Full Text Available The key to good maintenance of historic buildings is a long-range maintenance plan. Long-range planning recognizes a responsibility to the future to prolong the useful life of a building by preserving it in its present condition and preventing or slowing deterioration and damage from natural or other causes.

  19. Efficiency analysis of solar facilities for building heating and household water heating under conditions in the Czech Republic

    OpenAIRE

    Pivko, Michal; Jursová, Simona; Turjak, Juraj

    2012-01-01

    The paper studies the efficiency of solar facilities applied for the heating of buildings and household water heating in the Czech Republic. The Czech Republic is situated in the temperate zone characterized by changeable weather. It is respected in the assessment of a solar facility installation. The efficiency of solar facilities is evaluated according to energy and economic balances. It is analyzed for solar facilities heating both household water and buildings. The main problems relating ...

  20. Features of risks, damage claims processing and damage prevention overseas. Pt. 1

    Energy Technology Data Exchange (ETDEWEB)

    Splittgerber, E

    1981-01-01

    In opening up new raw material resources in remote locations and in the erection of industrial installations in overseas countries, manufacturers are often confronted with additional, unusual and hitherto unknown risks which can have considerable influence upon the orderly and timely execution of their projects. In Part I, various risk factors are considered from the experiences of Allianz as technical insurer in foreign damages connected with plant, civil and installation work insurance. The influence of climatic conditions upon damage events is illustrated with examples and the effects of storm, sand storm, flooding and earthquake discussed using a world map of natural dangers. The customs of people from culturally different nations and races, dictated as they often are by religion, must be taken into account by site managers and other staff on the building sites. The necessity for improvisations on building sites far from home and the limits of such improvisations are also discussed.

  1. The Fukushima Dai-ichi nuclear accident - Management of radioactive waters from damaged reactors. Situation in March 2014

    International Nuclear Information System (INIS)

    2014-03-01

    This report first describes the general context regarding the water issue in the Fukushima power station: accumulation and continuous input of water in the buildings. It describes the actions undertaken by TEPCO to process this water: desalination to avoid corrosion phenomena, and decontamination from various radionuclides. But this processing is only the first step of the whole water management process. The report describes how TEPCO stores these huge and always increasing quantities of radioactive water, and of course faces problems of leakages

  2. Monitoring of Water Content in Building Materials Using a Wireless Passive Sensor

    Directory of Open Access Journals (Sweden)

    Goran Stojanović

    2010-04-01

    Full Text Available This paper describes an innovative design of a wireless, passive LC sensor and its application for monitoring of water content in building materials. The sensor was embedded in test material samples so that the internal water content of the samples could be measured with an antenna by tracking the changes in the sensor’s resonant frequency. Since the dielectric constant of water was much higher compared with that of the test samples, the presence of water in the samples increased the capacitance of the LC circuit, thus decreasing the sensor’s resonant frequency. The sensor is made up of a printed circuit board in one metal layer and water content has been determined for clay brick and autoclaved aerated concrete block, both widely used construction materials. Measurements were conducted at room temperature using a HP-4194A Impedance/Gain-Phase Analyzer instrument.

  3. Building Change Detection from Harvey using Unmanned Aerial System (UAS)

    Science.gov (United States)

    Chang, A.; Yeom, J.; Jung, J.; Choi, I.

    2017-12-01

    Unmanned Aerial System (UAS) is getting to be the most important technique in recent days since the fine spatial and high temporal resolution data previously unobtainable from traditional remote sensing platforms. Advanced UAS data can provide a great opportunity for disaster monitoring. Especially, building change detection is the one of the most important topics for damage assessment and recovery from disasters. This study is proposing a method to monitor building change with UAS data for Holiday Beach in Texas, where was directly hit by Harvey on 25 August 2017. This study adopted 3D change detection to monitor building damage and recovery levels with building height as well as natural color information. We used a rotorcraft UAS to collect RGB data twice on 9 September and 18 October 2017 after the hurricane. The UAS data was processed using Agisoft Photoscan Pro Software to generate super high resolution dataset including orthomosaic, DSM (Digital Surface Model), and 3D point cloud. We compared the processed dataset with an airborne image considerable as before-hurricane data, which was acquired on January 2016. Building damage and recovery levels were determined by height and color change. The result will show that UAS data is useful to assess building damage and recovery for affected area by the natural disaster such as Harvey.

  4. Assessment of Seismic Vulnerability of Reinforced Concrete Frame buildings

    Directory of Open Access Journals (Sweden)

    Fatiha Cherifi

    2018-01-01

    Full Text Available The seismic activity remains strong in the north of Algeria since no less than 30 earthquakes per month are recorded. The large number of structures built before the introduction of the seismic standards represents a high seismic risk. Analysis of damage suffered during the last earthquakes highlighted the vulnerability of the existing structures. In this study the seismic behavior of the existing buildings in Tizi-Ouzou city, located in the north of Algeria, is investigated. To make this assessment, a database was created following a building inventory based on a set of technical folders and field visits. The listed buildings have been classified into different typologies. Only reinforced concrete frame buildings are considered in this paper. The approach adopted to estimate structures damage is based on four main steps: 1 construction of capacity curves using static nonlinear method “push-over”, 2 estimate of seismic hazard, 3 determination of performance points, and finally 4 deduction of damage levels.

  5. Estimation of solar collector area for water heating in buildings of Malaysia

    Science.gov (United States)

    Manoj Kumar, Nallapaneni; Sudhakar, K.; Samykano, M.

    2018-04-01

    Solar thermal energy (STE) utilization for water heating at various sectorial levels became popular and still growing especially for buildings in the residential area. This paper aims to study and identify the solar collector area needed based on the user requirements in an efficient manner. A step by step mathematical approach is followed to estimate the area in Sq. m. Four different cases each having different hot water temperatures (45°, 50°C, 55°C, and 60°C) delivered by the solar water heating system (SWHS) for typical residential application at Kuala Lumpur City, Malaysia is analysed for the share of hot and cold water mix. As the hot water temperature levels increased the share of cold water mix is increased to satisfy the user requirement temperature, i.e. 40°C. It is also observed that as the share of hot water mix is reduced, the collector area can also be reduced. Following this methodology at the installation stage would help both the user and installers in the effective use of the solar resource.

  6. Indoor microbiota in severely moisture damaged homes and the impact of interventions.

    Science.gov (United States)

    Jayaprakash, Balamuralikrishna; Adams, Rachel I; Kirjavainen, Pirkka; Karvonen, Anne; Vepsäläinen, Asko; Valkonen, Maria; Järvi, Kati; Sulyok, Michael; Pekkanen, Juha; Hyvärinen, Anne; Täubel, Martin

    2017-10-13

    The limited understanding of microbial characteristics in moisture-damaged buildings impedes efforts to clarify which adverse health effects in the occupants are associated with the damage and to develop effective building intervention strategies. The objectives of this current study were (i) to characterize fungal and bacterial microbiota in house dust of severely moisture-damaged residences, (ii) to identify microbial taxa associated with moisture damage renovations, and (iii) to test whether the associations between the identified taxa and moisture damage are replicable in another cohort of homes. We applied bacterial 16S rRNA gene and fungal ITS amplicon sequencing complemented with quantitative PCR and chemical-analytical approaches to samples of house dust, and also performed traditional cultivation of bacteria and fungi from building material samples. Active microbial growth on building materials had significant though small influence on the house dust bacterial and fungal communities. Moisture damage interventions-including actual renovation of damaged homes and cases where families moved to another home-had only a subtle effect on bacterial community structure, seen as shifts in abundance weighted bacterial profiles after intervention. While bacterial and fungal species richness were reduced in homes that were renovated, they were not reduced for families that moved houses. Using different discriminant analysis tools, we were able identify taxa that were significantly reduced in relative abundance during renovation of moisture damage. For bacteria, the majority of candidates belonged to different families within the Actinomycetales order. Results for fungi were overall less consistent. A replication study in approximately 400 homes highlighted some of the identified taxa, confirming associations with observations of moisture damage and mold. The present study is one of the first studies to analyze changes in microbiota due to moisture damage interventions

  7. Power generation by high head water in a building using micro hydro turbine-a greener approach.

    Science.gov (United States)

    M M S R S, Bhargav; V, Ratna Kishore; S P, Anbuudayasankar; K, Balaji

    2016-05-01

    Demand for green energy production is arising all over the world. A lot of emphasis is laid in making the buildings green. Even a small amount of energy savings made contribute to saving the environment. In this study, an idea is proposed and studied to extract power from the high head water in the pipelines of a building. A building of height 15 m is considered for this study. Water flowing in the pipe has sufficient energy to run a micro hydro turbine. The feasibility of producing electrical energy from the energy of pipe water is found. The motivation is to find the feasibility of generating power using a low-cost turbine. The experimental setup consists of micro turbine of 135 mm diameter coupled to a 12-V DC generator; LEDs and resistors are employed to validate the results. The theoretical calculations were presented using the fundamental equations of fluid mechanics. The theoretical results are validated using experimental and numerical results using CFD simulation. In addition, exergy analysis has been carried out to quantify the irreversibilities during the process in the system.

  8. Study and Optimization of Design Parameters in Water Loop Heat Pump Systems for Office Buildings in the Iberian Peninsula

    Directory of Open Access Journals (Sweden)

    Francisco Javier Fernández

    2017-11-01

    Full Text Available Water loop heat pump (WLHP air conditioning systems use heat pumps connected to a common water circuit to fulfill the energy demands of different thermal zones in a building. In this study, the energy consumption was analyzed for the air conditioning of an office building in the typical climate of four important cities of the Iberian Peninsula. The energy consumption of one water loop heat pump system was compared with a conventional water system. Two design parameters, the range in the control temperatures and the water loop thermal storage size, were tested. Energy redistribution is an important advantage of the WLHP system, but significant savings came from high efficiency parameters in the heat pumps and minor air flow rates in the cooling tower. The low thermal level in the water loop makes this technology appropriate to combine with renewable sources. Using natural gas as the thermal energy source, a mean decrease in CO2 emissions of 8.1% was reached. Simulations showed that the installation of big thermal storage tanks generated small energy savings. Besides, the total annual consumption in buildings with high internal loads can be reduced by keeping the water loop as cool as possible.

  9. Building America Case Study: Multifamily Central Heat Pump Water Heaters, Davis, California

    Energy Technology Data Exchange (ETDEWEB)

    M. Hoeschele, E. Weitzel

    2017-03-01

    Although heat pump water heaters (HPWHs) have gained significant attention in recent years as a high efficiency electric water heating solution for single family homes, central HPWHs for commercial or multi-family applications are not as well documented in terms of measured performance and cost effectiveness. To evaluate this technology, the Alliance for Residential Building Innovation team monitored the performance of a 10.5 ton central HPWH installed on a student apartment building at the West Village Zero Net Energy Community in Davis, California. Monitoring data collected over a 16-month period were then used to validate a TRNSYS simulation model. The TRNSYS model was then used to project performance in different climates using local electric rates. Results of the study indicate that after some initial commissioning issues, the HPWH operated reliably with an annual average efficiency of 2.12 (Coefficient of Performance). The observed efficiency was lower than the unit's rated efficiency, primarily due to the fact that the system rarely operated under steady-state conditions. Changes in the system configuration, storage tank sizing, and control settings would likely improve the observed field efficiency. Modeling results suggest significant energy savings relative to electric storage water heating systems (typical annual efficiencies around 0.90) providing for typical simple paybacks of six to ten years without any incentives. The economics versus gas water heating are currently much more challenging given the current low natural gas prices in much of the country. Increased market size for this technology would benefit cost effectiveness and spur greater technology innovation.

  10. Building America Case Study: Multifamily Central Heat Pump Water Heaters, Davis, California

    Energy Technology Data Exchange (ETDEWEB)

    2017-03-08

    Although heat pump water heaters (HPWHs) have gained significant attention in recent years as a high efficiency electric water heating solution for single family homes, central HPWHs for commercial or multi-family applications are not as well documented in terms of measured performance and cost effectiveness. To evaluate this technology, the Alliance for Residential Building Innovation team monitored the performance of a 10.5 ton central HPWH installed on a student apartment building at the West Village Zero Net Energy Community in Davis, California. Monitoring data collected over a 16-month period were then used to validate a TRNSYS simulation model. The TRNSYS model was then used to project performance in different climates using local electric rates. Results of the study indicate that after some initial commissioning issues, the HPWH operated reliably with an annual average efficiency of 2.12 (Coefficient of Performance). The observed efficiency was lower than the unit's rated efficiency, primarily due to the fact that the system rarely operated under steady-state conditions. Changes in the system configuration, storage tank sizing, and control settings would likely improve the observed field efficiency. Modeling results suggest significant energy savings relative to electric storage water heating systems (typical annual efficiencies around 0.90) providing for typical simple paybacks of six to ten years without any incentives. The economics versus gas water heating are currently much more challenging given the current low natural gas prices in much of the country. Increased market size for this technology would benefit cost effectiveness and spur greater technology innovation.

  11. Stone material investigations of the Riga Stock Exchange building

    Science.gov (United States)

    Igaune-Blumberga, S.; Vitina, I.; Lindina, L.; Timma, I.; Barbane, I.

    2011-12-01

    This paper deals with the stone material investigation of former Riga Stock Exchange building and presents the following aspects: characterization of materials, analyses of mortars for sealing and cladding of artificial marble, decors, bricks, render of sealing, analyses of soluble salts, analyses of deteriorated granite surface of foundation. The last damage by fire was in 1979 which caused the collapse of the roof and consequently an infiltration of rain water. The conditions of the objects were found in very bad condition-deterioration represented by salt efflorescence's, cracking and in very large areas there was a complete loss of the artificial marble (stucco marble).

  12. Determination of fungal spore release from wet building materials

    DEFF Research Database (Denmark)

    Kildesø, J.; Wurtz, H.; Nielsen, Kristian Fog

    2003-01-01

    The release and transport of fungal spores from water-damaged building materials is a key factor for understanding the exposure to particles of fungal origin as a possible cause of adverse health effects associated to growth of fungi indoors. In this study, the release of spores from nine species...... of typical indoor fungi has been measured under controlled conditions. The fungi were cultivated for a period of 4-6 weeks on sterilized wet wallpapered gypsum boards at a relative humidity (RH) of approximately 97%. A specially designed small chamber (P-FLEC) was placed on the gypsum board. The release...

  13. Stone material investigations of the Riga Stock Exchange building

    International Nuclear Information System (INIS)

    Igaune-Blumberga, S; Vitina, I; Lindina, L; Timma, I; Barbane, I

    2011-01-01

    This paper deals with the stone material investigation of former Riga Stock Exchange building and presents the following aspects: characterization of materials, analyses of mortars for sealing and cladding of artificial marble, decors, bricks, render of sealing, analyses of soluble salts, analyses of deteriorated granite surface of foundation. The last damage by fire was in 1979 which caused the collapse of the roof and consequently an infiltration of rain water. The conditions of the objects were found in very bad condition-deterioration represented by salt efflorescence's, cracking and in very large areas there was a complete loss of the artificial marble (stucco marble).

  14. Reconstruction of War Damaged Buildings - A Problem that Still Stands. The Case of the National Economy Bank in Warsaw Restored During the Second World War

    Directory of Open Access Journals (Sweden)

    Łotysz Sławomir

    2016-12-01

    Full Text Available The Polish national historiography remains silent on the reconstruction of damaged towns and cities that was undertaken by the German administration after capturing Poland in September 1939. This paper, on the war-time restoration of the National Economy Bank’s headquarters in Warsaw, is an attempt to at least partially fill the gap. Designed by celebrated architect Rudolf Świerczyński in the late 1920s in accordance with contemporary air raid defence regulations, it was bombed and nevertheless seriously damaged during the September Campaign. Under the German management of the bank, the building was reconstructed and even modernized by commissioned Polish engineers.

  15. Investigation of radiation damage to biological specimens at water window wavelengths

    International Nuclear Information System (INIS)

    Foster, G.F.; Buckley, C.J.; Burge, R.E.; Bennett, P.M.

    1992-01-01

    This article reports the continuation of a series of experiments investigating the effects of soft x-ray radiation damage on the contractile elements of mammalian striated muscle (myofibrils), using their ability to contract as a functional assay. The myofibrils were exposed to 385 eV x rays. This energy is within the ''water window'' between the oxygen and carbon K edges, where the x-ray absorption coefficient of biological materials, such as protein, is about an order of magnitude greater than that for water. An exposure of 8x10 5 photons μm -1 was found to prevent contraction in the majority of myofibrils. Preliminary results indicate that it is possible to increase this exposure level by approximately 25% by adding the radioprotective dimethyl sulphoxide (DMSO), an OH radical scavenger to the myofibril buffer during irradiation. This suggests that OH radicals are important in the inactivation of myofibrils through irradiation

  16. On the occurrence of rainstorm damage based on home insurance and weather data

    Science.gov (United States)

    Spekkers, M. H.; Clemens, F. H. L. R.; ten Veldhuis, J. A. E.

    2015-02-01

    Rainstorm damage caused by the malfunction of urban drainage systems and water intrusion due to defects in the building envelope can be considerable. Little research on this topic focused on the collection of damage data, the understanding of damage mechanisms and the deepening of data analysis methods. In this paper, the relative contribution of different failure mechanisms to the occurrence of rainstorm damage is investigated, as well as the extent to which these mechanisms relate to weather variables. For a case study in Rotterdam, the Netherlands, a property level home insurance database of around 3100 water-related damage claims was analysed. The records include comprehensive transcripts of communication between insurer, insured and damage assessment experts, which allowed claims to be classified according to their actual damage cause. The results show that roof and wall leakage is the most frequent failure mechanism causing precipitation-related claims, followed by blocked roof gutters, melting snow and sewer flooding. Claims related to sewer flooding were less present in the data, but are associated with significantly larger claim sizes than claims in the majority class, i.e. roof and wall leakages. Rare events logistic regression analysis revealed that maximum rainfall intensity and rainfall volume are significant predictors for the occurrence probability of precipitation-related claims. Moreover, it was found that claims associated with rainfall intensities smaller than 7-8 mm in a 60-min window are mainly related to failure processes in the private domain, such as roof and wall leakages. For rainfall events that exceed the 7-8 mm h-1 threshold, the failure of systems in the public domain, such as sewer systems, start to contribute considerably to the overall occurrence probability of claims. The communication transcripts, however, lacked information to be conclusive about to which extent sewer-related claims were caused by overloading of sewer systems or

  17. Building technique. Vol. 5. Construction engineering. Pt. 2. Building physics. Bautechnik. Bd. 5. Konstruktiver Ingenieurbau. T. 2. Bauphysik

    Energy Technology Data Exchange (ETDEWEB)

    Cziesielski, E [Technische Univ. Berlin (Germany, F.R.); ed.

    1988-01-01

    This volume on 'Building Technique' gives information on the following subjects: Interaction between building physics and building design (analysis, solutions); thermal protection (heat transfer, thermal protection requirements, energy saving); protection against damp (water economy, water transport, protection against rain); sealing buildings (material, stressing of buildings by humidity of the ground and service water, drainage, sealing); noise insulation (basic terms, sound absorption, acoustic phenomena, noise from domestic equipment, protection against outside noise); fire protection (technical building regulations, fire protection regulations, classes of building material, fire resistance classes, fire behaviour of special building components). The subsequent part of the report is concerned with the history of building design (design and building technique, tasks of the architect, year of birth of modern building design 1743. Prehistory of building design). (HWJ) With 186 figs.

  18. Building leadership capacity to drive sustainable water management: the evaluation of a customised program.

    Science.gov (United States)

    Taylor, A C

    2010-01-01

    This paper describes a customised, six-month, leadership development program (LDP) that was designed for emerging leaders in the Australian water industry who were promoting sustainable urban water management (SUWM). It also presents results from an evaluation of the program's benefits, costs and overall 'return on investment' (ROI). The program was designed to help build emergent leadership capacity in the water industry, given strong evidence that this form of leadership plays an important role in advancing SUWM. It involved '360-degree feedback' processes, training, individual leadership development plans, and coaching sessions. Its design was informed by a review of the literature, and its content was informed by local empirical research involving effective SUWM leaders. The evaluation used a seven-tier assessment framework that examined different dimensions of the program's performance using source and methodological triangulation. The results indicate that such LDPs can produce a range of positive outcomes, such as promoting desired leadership behaviours and generating a positive ROI estimate. Specifically, the program's estimated ROI was approximately 190% after only one year. The primary conclusion is that evidence-based LDPs which are highly customised for specific types of leaders in the water industry represent a promising type of intervention to build forms of leadership capacity which are needed to successfully promote SUWM.

  19. STRUCTURAL VULNERABILITY ASSESSMENT OF MASONRY BUILDINGS IN TURKEY

    OpenAIRE

    KORKMAZ, Kasım Armagan; CARHOGLU, Asuman Isıl

    2011-01-01

    Turkey is located in an active seismic zone. Mid to high rise R/C building and low rise masonry buildings are very common construction type in Turkey. In recent earthquakes, lots of existing buildings got damage including masonry buildings. Masonry building history in Turkey goes long years back. For sure, it is an important structure type for Turkey. Therefore, earthquake behavior and structural vulnerability of masonry buildings are crucial issues for Turkey as a earthquake prone country. I...

  20. Decommissioning of the MTR-605 process water building at the Idaho National Engineering Laboratory. Final report

    International Nuclear Information System (INIS)

    Browder, J.H.; Wills, E.L.

    1985-01-01

    Decontamination and decommissioning (D and D) of the unused radioactively contaminated portions of the MTR-605 building at the Test Reactor Area of the Idaho National Engineering Laboratory has been completed; this final report describes the D and D project. The building is a two-story concrete structure that was used to house piping systems to channel and control coolant water flow for the Materials Testing Reactor (MTR), a 40 MW (thermal) light water test reactor that was operated from 1952 until 1970 and then deactivated. D and D project objectives were to reduce potential environmental and radioactive contamination hazards to levels as low a reasonably achievable. Primary tasks of the D and D project were: to remove contaminated piping (about 400 linear ft of 36- and 30-in.-dia stainless steel pipe) and valves from the primary coolant pipe tunnels, to remove a primary coolant pump and piping, and to remove the three 8-ft-dia by 25-ft-long evaporators from the building second floor

  1. UAV-based urban structural damage assessment using object-based image analysis and semantic reasoning

    Science.gov (United States)

    Fernandez Galarreta, J.; Kerle, N.; Gerke, M.

    2015-06-01

    Structural damage assessment is critical after disasters but remains a challenge. Many studies have explored the potential of remote sensing data, but limitations of vertical data persist. Oblique imagery has been identified as more useful, though the multi-angle imagery also adds a new dimension of complexity. This paper addresses damage assessment based on multi-perspective, overlapping, very high resolution oblique images obtained with unmanned aerial vehicles (UAVs). 3-D point-cloud assessment for the entire building is combined with detailed object-based image analysis (OBIA) of façades and roofs. This research focuses not on automatic damage assessment, but on creating a methodology that supports the often ambiguous classification of intermediate damage levels, aiming at producing comprehensive per-building damage scores. We identify completely damaged structures in the 3-D point cloud, and for all other cases provide the OBIA-based damage indicators to be used as auxiliary information by damage analysts. The results demonstrate the usability of the 3-D point-cloud data to identify major damage features. Also the UAV-derived and OBIA-processed oblique images are shown to be a suitable basis for the identification of detailed damage features on façades and roofs. Finally, we also demonstrate the possibility of aggregating the multi-perspective damage information at building level.

  2. Performance of Buildings in the 2009 Western Sumatra Earthquake

    Science.gov (United States)

    Deierlein, G.; Hart, T.; Alexander, N.; Hausler, E.; Henderson, S.; Wood, K.; Cedillos, V.; Wijanto, S.; Cabrera, C.; Rudianto, S.

    2009-12-01

    The M7.6 earthquake of 30 September 2009 in Western Sumatra, Indonesia caused significant damage and collapse to hundreds of buildings and the deaths of 1,117 people. In Padang City, with a population of about 900,000 people, building collapse was the primary cause of deaths and serious injuries (313 deaths and 431 serious injuries). The predominant building construction types in Padang are concrete moment frames with brick infill and masonry bearing wall systems. Concrete frames are common in multistory commercial retail buildings, offices, schools, and hotels; and masonry bearing wall systems are primarily used in low-rise (usually single story) residential and school buildings. In general, buildings that collapsed did not conform to modern seismic engineering practices that are required by the current Indonesian building code and would be expected in regions of moderate to high seismicity. While collapse of multi-story concrete buildings was more prevalent in older buildings (more than 10 years old), there were several newer buildings that collapsed. Primary deficiencies identified in collapsed or severely damaged buildings included: (a) soft or weak stories that failed in either by sidesway mechanisms or shear failures followed by loss of axial capacity of columns, (b) lack of ductile reinforcing bar detailing in concrete beams, columns, and beam-column joints, (c) poor quality concrete and mortar materials and workmanship, (d) vulnerable building configurations and designs with incomplete or deficient load paths, and (e) out-of-plane wall failures in unreinforced (or marginally reinforced) masonry. While these deficiencies may be expected in older buildings, damage and collapse to some modern (or recently rennovated buildings) indicates a lack of enforcement of building code provisions for design and construction quality assurance. Many new buildings whose structural systems were undamaged were closed due to extensive earthquake damage to brick infill walls

  3. Seismic performance of existing R.C. framed buildings

    Directory of Open Access Journals (Sweden)

    Sameh A. El-Betar

    2017-08-01

    Full Text Available The earthquakes disasters basically occur due to buildings damage not because of the earth shaking. Therefore, the countries have being updated the seismic codes. The seismic loads for buildings design in Egyptian Code have been changed from (EC-1994 to (ECP-201, 2012. On the other hand, the need is raised to study the vulnerability of existing buildings, which can be divided into the buildings designed to resist the gravity loads only (GLD and the buildings designed according to Egyptian code (EC-1994. Comparison between forces due to Egyptian code for loads (EC-1994 and (ECP-201, 2012 is carried out on the multi-stories R.C. framed buildings which are the most common type of existing buildings in Egypt. To investigate the vulnerability of existing buildings, nonlinear static pushover analysis is conducted to evaluate the real strength of the existing buildings. Moreover, it is considered a useful and effective tool for the performance of three framed buildings: 3, 6 and 10 stories due to expected future earthquakes. Finally, it is found that the vulnerability of existing GLD buildings occurs at expected ground accelerations (ag greater than 0.125 g in Egyptian seismic map, while the EC-94 designed buildings behave elastically up to (ag equals to 0.2 g and above that a slight damage may occur.

  4. Damage From the Nahrin, Afghanistan, Earthquake of 25 March, 2002

    Science.gov (United States)

    Madden, C. L.; Yeats, R. S.

    2002-12-01

    On 25 March, 2002, a destructive earthquake of mb = 6.1 struck the city of Nahrin and nearby villages in Baghlan Province in northeastern Afghanistan. The earthquake occurred on a southeast-dipping reverse fault that parallels the linear northeast-trending range front of the Hindu Kush Mountains, east of Nahrin. Field reconnaissance showed no disturbance of the ground by surface rupture, liquefaction, or lateral spreading, and virtually no evidence of landsliding or rockfall. United Nations and Afghan authorities estimate the death toll from the earthquake to be over 2000, with about 20,000 families impacted by the earthquake. We conducted a survey of damage in 68 villages affected by the earthquake and found that areas within 25 km of the epicenter experienced modified Mercalli intensities of between VI and VII. Shaking intensities were strong enough to cause complete building collapse in many villages. Site conditions were an important factor in the distribution of damage in the Nahrin area. Houses built on the narrow crests of ridges eroded in loess suffered major damage due to the focusing of near-surface seismic waves on ridge-tops. Houses on low fluvial terraces along the Nahrin River also suffered major damage, likely due to their close proximity to the water table. Structures built on metamorphic bedrock and alluvial fans along the range front of the Hindu Kush Mountains or on high terraces along the Nahrin River suffered comparatively less damage. Building failure was predominantly caused by the mud-block construction, characteristic of much of Afghanistan and adjacent countries. Most houses are built of mud blocks made from reworked loess, which contains a relatively low percentage of clay. The walls contain no bracing against lateral shear, and wall corners are not tied together, leading to failure at corners and roof collapse. In several villages, mosques were constructed to a higher standard and suffered significantly less damage than surrounding mud

  5. Limiting salt crystallization damage in lime mortar by using crystallization modifiers

    NARCIS (Netherlands)

    Granneman, S.J.C.; Shahidzadeh, N.; Lubelli, B.A.; Hees, R.P.J. van

    2014-01-01

    Salt crystallization is a recurrent cause of damage in porous building materials. Lime-based mortars, which were widely used in construction of ancient masonry, are especially prone to salt damage, due to their low mechanical strength. Existing solutions to tackle salt damage in mortars have been

  6. Chapter 6: Fire damage of wood structures

    Science.gov (United States)

    B. Kukay; R.H. White; F. Woeste

    2012-01-01

    Depending on the severity, fire damage can compromise the structural integrity of wood structures such as buildings or residences. Fire damage of wood structures can incorporate several models that address (1) the type, cause, and spread of the fire, (2) the thermal gradients and fire-resistance ratings, and (3) the residual load capacity (Figure 6.1). If there is a...

  7. Evaluation methodology for flood damage reduction by preliminary water release from hydroelectric dams

    Science.gov (United States)

    Ando, T.; Kawasaki, A.; Koike, T.

    2017-12-01

    IPCC AR5 (2014) reported that rainfall in the middle latitudes of the Northern Hemisphere has been increasing since 1901, and it is claimed that warmer climate will increase the risk of floods. In contrast, world water demand is forecasted to exceed a sustainable supply by 40 percent by 2030. In order to avoid this expectable water shortage, securing new water resources has become an utmost challenge. However, flood risk prevention and the secure of water resources are contradictory. To solve this problem, we can use existing hydroelectric dams not only as energy resources but also for flood control. However, in case of Japan, hydroelectric dams take no responsibility for it, and benefits have not been discussed accrued by controlling flood by hydroelectric dams, namely by using preliminary water release from them. Therefore, our paper proposes methodology for assessing those benefits. This methodology has three stages as shown in Fig. 1. First, RRI model is used to model flood events, taking account of the probability of rainfall. Second, flood damage is calculated using assets in inundation areas multiplied by the inundation depths generated by that RRI model. Third, the losses stemming from preliminary water release are calculated, and adding them to flood damage, overall losses are calculated. We can evaluate the benefits by changing the volume of preliminary release. As a result, shown in Fig. 2, the use of hydroelectric dams to control flooding creates 20 billion Yen benefits, in the probability of three-day-ahead rainfall prediction of the assumed maximum rainfall in Oi River, in the Shizuoka Pref. of Japan. As the third priority in the Sendai Framework for Disaster Risk Reduction 2015-2030, `investing in disaster risk reduction for resilience - public and private investment in disaster risk prevention and reduction through structural and non-structural measures' was adopted. The accuracy of rainfall prediction is the key factor in maximizing the benefits

  8. Environmental, economic and energy analysis of double glazing with a circulating water chamber in residential buildings

    International Nuclear Information System (INIS)

    Gil-Lopez, Tomas; Gimenez-Molina, Carmen

    2013-01-01

    Highlights: ► Glazed façade area is the part that produces greatest energy losses and gains. ► A potential for energy savings has been detected in residential buildings. ► Active glazing comprising two laminated glass panels with a circulating water chamber. ► Analysis of energy performance, economic viability and impact on carbon footprint. ► Natural gas condensing boilers is the less contaminating and more efficient option. -- Abstract: In general, the glazed façade area of a building is the part that produces the greatest energy losses and gains. The basic aim of this work is to achieve a more efficient heat control in closed spaces. To this end, an exhaustive study has been made of active glazing comprising two laminated glass panels with a circulating water chamber. Not only has the energy consumption been analysed but also the energy efficiency according to fuel type, the amount of CO 2 emitted into the atmosphere and the economic cost. The results of this study, from the points of view of economic feasibility and energy efficiency, show that the solution of double glazing with a circulating water chamber is a less polluting and more efficient option than the systems currently used. This solution is able to reduce the energy losses and gains that are produced through the glazed façade of a building by 18.26% for calorific and frigorific energy compared to the total consumption of the building. The layout of the proposed installation facilitates its integration into any type of residential building, either under construction or being renovated. Moreover, its zero visual impact means it can even be implemented in places with strict town-planning regulations.

  9. Building air exhaustion device

    International Nuclear Information System (INIS)

    Suzuki, Seijiro.

    1995-01-01

    An opening is formed on the side wall of a building such as of a nuclear power plant, and a blow out panel is held (supported) by a clip for closing the opening. A large-diameter pipeline is connected at one end to the opening so as to cover the blow out panel, and immersed at the other end in a pool water. When a pipeline such as of main steam pipelines is ruptured in the building, high temperature and high pressure coolants are flown out from the ruptured port, and the pressure in the building is elevated. The blow out panel falls off from the side of the building by the elevation of the pressure in the building. Steams or compressed air discharged from the opening is introduced to the pool through the large diameter pipeline, then the steams are condensed by the pool water and radioactive materials contained in the condensed steams are kept in the pool water. Radioactive materials contained in the released compression air are also removed into the pool water. (I.N.)

  10. Comparative Study on Code-based Linear Evaluation of an Existing RC Building Damaged during 1998 Adana-Ceyhan Earthquake

    Science.gov (United States)

    Toprak, A. Emre; Gülay, F. Gülten; Ruge, Peter

    2008-07-01

    Determination of seismic performance of existing buildings has become one of the key concepts in structural analysis topics after recent earthquakes (i.e. Izmit and Duzce Earthquakes in 1999, Kobe Earthquake in 1995 and Northridge Earthquake in 1994). Considering the need for precise assessment tools to determine seismic performance level, most of earthquake hazardous countries try to include performance based assessment in their seismic codes. Recently, Turkish Earthquake Code 2007 (TEC'07), which was put into effect in March 2007, also introduced linear and non-linear assessment procedures to be applied prior to building retrofitting. In this paper, a comparative study is performed on the code-based seismic assessment of RC buildings with linear static methods of analysis, selecting an existing RC building. The basic principles dealing the procedure of seismic performance evaluations for existing RC buildings according to Eurocode 8 and TEC'07 will be outlined and compared. Then the procedure is applied to a real case study building is selected which is exposed to 1998 Adana-Ceyhan Earthquake in Turkey, the seismic action of Ms = 6.3 with a maximum ground acceleration of 0.28 g It is a six-storey RC residential building with a total of 14.65 m height, composed of orthogonal frames, symmetrical in y direction and it does not have any significant structural irregularities. The rectangular shaped planar dimensions are 16.40 m×7.80 m = 127.90 m2 with five spans in x and two spans in y directions. It was reported that the building had been moderately damaged during the 1998 earthquake and retrofitting process was suggested by the authorities with adding shear-walls to the system. The computations show that the performing methods of analysis with linear approaches using either Eurocode 8 or TEC'07 independently produce similar performance levels of collapse for the critical storey of the structure. The computed base shear value according to Eurocode is much higher

  11. Comparative Study on Code-based Linear Evaluation of an Existing RC Building Damaged during 1998 Adana-Ceyhan Earthquake

    International Nuclear Information System (INIS)

    Toprak, A. Emre; Guelay, F. Guelten; Ruge, Peter

    2008-01-01

    Determination of seismic performance of existing buildings has become one of the key concepts in structural analysis topics after recent earthquakes (i.e. Izmit and Duzce Earthquakes in 1999, Kobe Earthquake in 1995 and Northridge Earthquake in 1994). Considering the need for precise assessment tools to determine seismic performance level, most of earthquake hazardous countries try to include performance based assessment in their seismic codes. Recently, Turkish Earthquake Code 2007 (TEC'07), which was put into effect in March 2007, also introduced linear and non-linear assessment procedures to be applied prior to building retrofitting. In this paper, a comparative study is performed on the code-based seismic assessment of RC buildings with linear static methods of analysis, selecting an existing RC building. The basic principles dealing the procedure of seismic performance evaluations for existing RC buildings according to Eurocode 8 and TEC'07 will be outlined and compared. Then the procedure is applied to a real case study building is selected which is exposed to 1998 Adana-Ceyhan Earthquake in Turkey, the seismic action of Ms = 6.3 with a maximum ground acceleration of 0.28 g It is a six-storey RC residential building with a total of 14.65 m height, composed of orthogonal frames, symmetrical in y direction and it does not have any significant structural irregularities. The rectangular shaped planar dimensions are 16.40 mx7.80 m = 127.90 m 2 with five spans in x and two spans in y directions. It was reported that the building had been moderately damaged during the 1998 earthquake and retrofitting process was suggested by the authorities with adding shear-walls to the system. The computations show that the performing methods of analysis with linear approaches using either Eurocode 8 or TEC'07 independently produce similar performance levels of collapse for the critical storey of the structure. The computed base shear value according to Eurocode is much higher

  12. The influence of water/air cooling on collateral tissue damage using a diode laser with an innovative pulse design (micropulsed mode)-an in vitro study.

    Science.gov (United States)

    Beer, F; Körpert, W; Buchmair, A G; Passow, H; Meinl, A; Heimel, P; Moritz, A

    2013-05-01

    Since the diode laser is a good compromise for the daily use in dental offices, finding usage in numerous dental indications (e.g., surgery, periodontics, and endodontics), the minimization of the collateral damage in laser surgery is important to improve the therapeutical outcome. The aim of this study was to investigate the effect of water/air cooling on the collateral thermal soft tissue damage of 980-nm diode laser incisions. A total of 36 mechanically executed laser cuts in pork liver were made with a 980-nm diode laser in micropulsed mode with three different settings of water/air cooling and examined by histological assessment to determine the area and size of carbonization, necrosis, and reversible tissue damage as well as incision depth and width. In our study, clearly the incision depth increased significantly under water/air cooling (270.9 versus 502.3 μm-test group 3) without significant changes of incision width. In test group 2, the total area of damage was significantly smaller than in the control group (in this group, the incision depth increases by 65 %). In test group 3, the total area of damage was significantly higher (incision depth increased by 85 %), but the bigger part of it represented a reversible tissue alteration leaving the amount of irreversible damage almost the same as in the control group. This first pilot study clearly shows that water/air cooling in vitro has an effect on collateral tissue damage. Further studies will have to verify, if the reduced collateral damage we have proved in this study can lead to accelerated wound healing. Reduction of collateral thermal damage after diode laser incisions is clinically relevant for promoted wound healing.

  13. Hot water extract of Chlorella vulgaris induced DNA damage and apoptosis

    Science.gov (United States)

    Yusof, Yasmin Anum Mohd; Md. Saad, Suhana; Makpol, Suzana; Shamaan, Nor Aripin; Ngah, Wan Zurinah Wan

    2010-01-01

    OBJECTIVES: The aim of this study was to determine the antiproliferative and apoptotic effects of hot water extracts of Chlorella vulgaris on hepatoma cell line HepG2. INTRODUCTION: The search for food and spices that can induce apoptosis in cancer cells has been a major study interest in the last decade. Chlorella vulgaris, a unicellular green algae, has been reported to have antioxidant and anti‐cancer properties. However, its chemopreventive effects in inhibiting the growth of cancer cells have not been studied in great detail. METHODS: HepG2 liver cancer cells and WRL68 normal liver cells were treated with various concentrations (0‐4 mg/ml) of hot water extract of C. vulgaris after 24 hours incubation. Apoptosis rate was evaluated by TUNEL assay while DNA damage was assessed by Comet assay. Apoptosis proteins were evaluated by Western blot analysis. RESULTS: Chlorella vulgaris decreased the number of viable HepG2 cells in a dose dependent manner (p Chlorella vulgaris tested. Evaluation of apoptosis by TUNEL assay showed that Chlorella vulgaris induced a higher apoptotic rate (70%) in HepG2 cells compared to normal liver cells, WRL68 (15%). Western blot analysis showed increased expression of pro‐ apoptotic proteins P53, Bax and caspase‐3 in the HepG2 cells compared to normal liver cells WRL68, and decreased expression of the anti‐apoptotic protein Bcl‐2. CONCLUSIONS: Chlorella vulgaris may have anti‐cancer effects by inducing apoptosis signaling cascades via an increased expression of P53, Bax and caspase‐3 proteins and through a reduction of Bcl‐2 protein, which subsequently lead to increased DNA damage and apoptosis. PMID:21340229

  14. Quantification of flood risk mitigation benefits: A building-scale damage assessment through the RASOR platform.

    Science.gov (United States)

    Arrighi, Chiara; Rossi, Lauro; Trasforini, Eva; Rudari, Roberto; Ferraris, Luca; Brugioni, Marcello; Franceschini, Serena; Castelli, Fabio

    2018-02-01

    Flood risk mitigation usually requires a significant investment of public resources and cost-effectiveness should be ensured. The assessment of the benefits of hydraulic works requires the quantification of (i) flood risk in absence of measures, (ii) risk in presence of mitigation works, (iii) investments to achieve acceptable residual risk. In this work a building-scale is adopted to estimate direct tangible flood losses to several building classes (e.g. residential, industrial, commercial, etc.) and respective contents, exploiting various sources of public open data in a GIS environment. The impact simulations for assigned flood hazard scenarios are computed through the RASOR platform which allows for an extensive characterization of the properties and their vulnerability through libraries of stage-damage curves. Recovery and replacement costs are estimated based on insurance data, market values and socio-economic proxies. The methodology is applied to the case study of Florence (Italy) where a system of retention basins upstream of the city is under construction to reduce flood risk. Current flood risk in the study area (70 km 2 ) is about 170 Mio euros per year without accounting for people, infrastructures, cultural heritage and vehicles at risk. The monetary investment in the retention basins is paid off in about 5 years. However, the results show that although hydraulic works are cost-effective, a significant residual risk has to be managed and the achievement of the desired level of acceptable risk would require about 1 billion euros of investments. Copyright © 2017 Elsevier Ltd. All rights reserved.

  15. Risk of a large amount of high-radioactive contaminated water leaking into the reactor building basement of Fukushima Daiichi nuclear power station

    International Nuclear Information System (INIS)

    Ebisawa, Toru; Sawai, Masako

    2013-01-01

    In November 2012 about one and half year after the accident at units 1, 2 and 3 of Fukushima Daiichi nuclear power station, some 405 m 3 /day cooling water was being injected into the melt damaged core and leaked as highly-radioactive contaminated water from damaged lower part of containment into the basement of turbine hall. To treat a large amount of contaminated water in the basement, waste processing plant to remove cesium was installed in June 2011 with desalination plant, which produced clean water for circulating coolant system of damaged nuclear fuel while the rest went to storage. Radioactivity of contaminated water in the basement accumulated at initial almost 80 days of the accident was evaluated about 20% for Cs-137 of core inventory of units 1, 2 and 3 and 2.3% for Sr-90 of core inventory of units 2 and 3. Sr-90 from unit 1 was not released into the basement and almost remained at suppression chamber. By November 2012, Cs-137 released into the basement was evaluated to total about 40% of core inventory and stored contaminated water amounted to about 360 kilotons, while Cs-137 released into the atmosphere was estimated about 3.6% of core inventory with its one third contributed for land contamination. Sr-90 released into the basement was estimated as 6.3% or 4.4% of core inventory based on Sr-90 measured activity of treated water in December or September 2011 with stored contaminated water of 300 kilotons. Cs-137 and Sr-90 contaminated water kept continuously releasing into the basement as long as melt damaged core existed and cooling water washed out Cs-137 and Sr-90 attached on containment walls. Safe store of released radioactivity was highly important and acquired important data was recommended to publish for check and review. (T. Tanaka)

  16. An estimation of core damage frequency of a pressurized water reactor during mid-loop operation

    International Nuclear Information System (INIS)

    Chao, C.C.; Chen, C.T.; Lee, M.

    2004-01-01

    The core damage frequency during mid-loop operation of a Westinghouse designed 3-loop Pressurizer Water Reactor (PWR) due to loss of Residual Heat Removal (RHR) events was assessed. The assessment considers two types of outages (refueling and drained maintenance), and uses failure data collected specifically for shutdown condition. Event trees were developed for five categories of loss of RHR events. Human actions to mitigate the loss of RHR events was identified and human error probabilities were quantified using HCR and THERP model. The result showed that the core damage frequency due to loss of RHR events during mid-loop operation is 3.1x10 -5 per year. The results also showed that the core damage frequency can be reduced significantly by removing a pressurizer safety valve before entering mid-loop operation. The establishment of reflux cooling, i.e. decay heat removal through steam generator secondary side also plays important role in mitigating the loss of RHR events. (author)

  17. Will building new reservoirs always help increase the water supply reliability? - insight from a modeling-based global study

    Science.gov (United States)

    Zhuang, Y.; Tian, F.; Yigzaw, W.; Hejazi, M. I.; Li, H. Y.; Turner, S. W. D.; Vernon, C. R.

    2017-12-01

    More and more reservoirs are being build or planned in order to help meet the increasing water demand all over the world. However, is building new reservoirs always helpful to water supply? To address this question, the river routing module of Global Change Assessment Model (GCAM) has been extended with a simple yet physical-based reservoir scheme accounting for irrigation, flood control and hydropower operations at each individual reservoir. The new GCAM river routing model has been applied over the global domain with the runoff inputs from the Variable Infiltration Capacity Model. The simulated streamflow is validated at 150 global river basins where the observed streamflow data are available. The model performance has been significantly improved at 77 basins and worsened at 35 basins. To facilitate the analysis of additional reservoir storage impacts at the basin level, a lumped version of GCAM reservoir model has been developed, representing a single lumped reservoir at each river basin which has the regulation capacity of all reservoir combined. A Sequent Peak Analysis is used to estimate how much additional reservoir storage is required to satisfy the current water demand. For basins with water deficit, the water supply reliability can be improved with additional storage. However, there is a threshold storage value at each basin beyond which the reliability stops increasing, suggesting that building new reservoirs will not help better relieve the water stress. Findings in the research can be helpful to the future planning and management of new reservoirs.

  18. Hanford site post-NPH building inspection plan

    International Nuclear Information System (INIS)

    Wagenblast, G.R. Westinghouse Hanford

    1996-01-01

    This plan establishes consistent post-NPH building inspection procedures and defines a procedure for prioritization of buildings for inspection to ensure the safety of facilities prior to reentry. Qualification of systems for restart of operation is not included. This plan takes advantage, where possible, of existing national procedures for post-NPH inspection of buildings, of existing structural design and evaluation documentation of Hanford facilities, and current and proposed seismic instrumentation located throughout the Hanford site. A list of buildings, prioritized according to current building safety function and building vulnerability (without regard for or information about a damaging natural forces event) is provided

  19. Buildings vs. ballistics: Quantifying the vulnerability of buildings to volcanic ballistic impacts using field studies and pneumatic cannon experiments

    Science.gov (United States)

    Williams, G. T.; Kennedy, B. M.; Wilson, T. M.; Fitzgerald, R. H.; Tsunematsu, K.; Teissier, A.

    2017-09-01

    Recent casualties in volcanic eruptions due to trauma from blocks and bombs necessitate more rigorous, ballistic specific risk assessment. Quantitative assessments are limited by a lack of experimental and field data on the vulnerability of buildings to ballistic hazards. An improved, quantitative understanding of building vulnerability to ballistic impacts is required for informing appropriate life safety actions and other risk reduction strategies. We assessed ballistic impacts to buildings from eruptions at Usu Volcano and Mt. Ontake in Japan and compiled available impact data from eruptions elsewhere to identify common damage patterns from ballistic impacts to buildings. We additionally completed a series of cannon experiments which simulate ballistic block impacts to building claddings to investigate their performance over a range of ballistic projectile velocities, masses and energies. Our experiments provide new insights by quantifying (1) the hazard associated with post-impact shrapnel from building and rock fragments; (2) the effect of impact obliquity on damage; and (3) the additional impact resistance buildings possess when claddings are struck in areas directly supported by framing components. This was not well identified in previous work which may have underestimated building vulnerability to ballistic hazards. To improve assessment of building vulnerability to ballistics, we use our experimental and field data to develop quantitative vulnerability models known as fragility functions. Our fragility functions and field studies show that although unreinforced buildings are highly vulnerable to large ballistics (> 20 cm diameter), they can still provide shelter, preventing death during eruptions.

  20. Economic Valuation of On Site Material Damages of High Water on Economic Activities based in the City of Venice: Results from a Dose-Response-Expert-Based Valuation Approach

    OpenAIRE

    Paulo A.L.D. Nunes; Margaretha Breil; Gretel Gambarelli

    2005-01-01

    The paper focuses on the economic assessment of damages caused by high water in the city of Venice. In particular, we focus our attention on a valuation exercise that addresses the estimation of monetary, short period, on-site damages due to high water events on the different business activities located in Venice. On-site damages include both mitigation costs, which refer to all types of financial expenditure undergone to avert physical and material damages caused by flooding, and remediation...

  1. Green Building Tools for Tribes

    Science.gov (United States)

    Tribal green building tools and funding information to support tribal building code adoption, healthy building, siting, energy efficiency, renewable energy, water conservation, green building materials, recycling and adaptation and resilience.

  2. Less mining-induced damage through slowed-down working. Geringe Bergbauschaeden durch langsamen Abbau

    Energy Technology Data Exchange (ETDEWEB)

    Kratzsch, H [Technische Univ. Berlin (Germany). Inst. fuer Bergbauwissenschaften

    1994-10-01

    Today's widely spread view that rapid deformation will enhance damage to buildings was not underpinned by major reasons of soil mechanics and building physics. It is true that a shower rise in deformation will favour grain relocation in the foundation soil and, as a result, will diminish the soil pressure on cellar walls or on pipes embedded in the ground in the pressurized zone and will reduce the floor-level pressure peak in the bending zone by subsequent settling of foundation components. However, damage will not be found to differ in degree if deformation had lasted for 50 days ([nu][sub A]=8 m/d) or 200 days ([nu][sub A]=2 m/d). It may be assumed to be hardly relevant for the degree of damage sustained if bending, shifting (friction), tearing (shearing) or pressing of a building part (e.g. wall, ceiling, pillar), or of a building element (e.g. brick, mortar injoints) or of a building composed of all these parts rise to their final levels within a period of 50 or 200 days. (orig./MSK)

  3. Auxiliary buildings

    International Nuclear Information System (INIS)

    Lakner, I.; Lestyan, E.

    1979-01-01

    The nuclear power station represents a complicated and a particular industrial project. Consequently, the design of the auxiliary buildings serving the power station (offices, kitchen, refreshment room, workshops, depots, water treatment plant building, boiler houses, etc.) requires more attention than usual. This chapter gives a short survey of the auxiliary buildings already completed and discusses the problems of their design, location and structure. (author)

  4. The assessment of water loss from a damaged distribution pipe using the FEFLOW software

    Directory of Open Access Journals (Sweden)

    Iwanek Małgorzata

    2017-01-01

    Full Text Available Common reasons of real water loss in distribution systems are leakages caused by the failures or pipe breakages. Depending on the intensity of leakage from a damaged buried pipe, water can flow to the soil surface just after the failure occurs, much later or never at all. The localization of the place where the pipe breakage occurs is relatively easy when water outflow occurs on the soil surface. The volume of lost water strongly depends on the time it takes to localize the place of a pipe breakage. The aim of this paper was to predict the volume of water lost between the moment of a failure occurring and the moment of water outflow on the soil surface, during a prospective failure in a distribution system. The basis of the analysis was a numerical simulation of a water pipe failure using the FEFLOW v. 5.3 software (Finite Element subsurface FLOW systems for a real middle-sized distribution system. Simulations were conducted for variants depending on pipes’ diameter (80÷200 mm for minimal and maximal hydraulic pressure head in the system (20.14 and 60.41 m H2O, respectively. FEFLOW software application enabled to select places in the water system where possible failures would be difficult to detect.

  5. Toward city-scale water quality control: building a theory for smart stormwater systems

    Science.gov (United States)

    Kerkez, B.; Mullapudi, A. M.; Wong, B. P.

    2016-12-01

    Urban stormwater systems are rarely designed as actual systems. Rather, it is often assumed that individual Best Management Practices (BMPs) will add up to achieve desired watershed outcomes. Given the rise of BMPs and green infrastructure, we ask: does doing "best" at the local scale guarantee the "best" at the global scale? Existing studies suggest that the system-level performance of distributed stormwater practices may actually adversely impact watersheds by increasing downstream erosion and reducing water quality. Optimizing spatial placement may not be sufficient, however, since precipitation variability and other sources of uncertainty can drive the overall system into undesirable states. To that end, it is also important to control the temporal behavior of the system, which can be achieved by equipping stormwater elements (ponds, wetlands, basins, bioswales, etc.) with "smart" sensors and valves. Rather than building new infrastructure, this permits for existing assets to be repurposed and controlled to adapt to individual storm events. While we have learned how to build and deploy the necessary sensing and control technologies, we do not have a framework or theory that combines our knowledge of hydrology, hydraulics, water quality and control. We discuss the development of such a framework and investigate how existing water domain knowledge can be transferred into a system-theoretic context to enable real-time, city-scale stormwater control. We apply this framework to water quality control in an urban watershed in southeast Michigan, which has been heavily instrumented and retrofitted for control over the past year.

  6. Capacity building in water demand management as a key component for attaining millennium development goals

    Science.gov (United States)

    Gumbo, Bekithemba; Forster, Laura; Arntzen, Jaap

    Successful water demand management (WDM) implementation as a component of integrated water resource management (IWRM) can play a significant role in the alleviation of poverty through more efficient use of available water resources. The urban population in Southern African cities is characterised by so-called ‘water poor’ communities who typically expend a high percentage of their household income on poor quality water. Usually they have no access to an affordable alternative source. Although WDM as a component of IWRM is not a panacea for poverty, it can help alleviate poverty by facilitating water services management by municipal water supply agencies (MWSAs) in the region. WDM is a key strategy for achieving the millennium development goals (MDGs) and, as such, should be given due attention in the preparation of national IWRM and water efficiency plans. Various studies in the Southern African region have indicated that capacity building is necessary for nations to develop IWRM and water-use efficiency plans to meet the targets set out in the MDGs. WDM education and training of water professionals and end-users is particularly important in developing countries, which are resource and information-access poor. In response to these findings, The World Conservation Union (IUCN) and its consulting partners, the Training and Instructional Design Academy of South Africa (TIDASA), and Centre for Applied Research (CAR) designed, developed and presented a pilot WDM Guideline Training Module for MWSAs as part of Phase II of IUCN’s Southern Africa regional WDM project. Pilot training was conducted in July 2004 in Lusaka, Zambia for a group of 36 participants involved in municipal water supply from nine Southern African countries. This paper looks at the links between building the capacity of professionals, operational staff and other role-players in the municipal water supply chain to implement WDM as part of broader IWRM strategies, and the subsequent potential for

  7. Analysis of Embodied Environmental Impacts of Korean Apartment Buildings Considering Major Building Materials

    Directory of Open Access Journals (Sweden)

    Seungjun Roh

    2018-05-01

    Full Text Available Because the reduction in environmental impacts (EIs of buildings using life-cycle assessment (LCA has been emphasized as a practical strategy for the sustainable development of the construction industry, studies are required to analyze not only the operational environmental impacts (OEIs of buildings, but also the embodied environmental impacts (EEIs of building materials. This study aims to analyze the EEIs of Korean apartment buildings on the basis of major building materials as part of research with the goal of reducing the EIs of buildings. For this purpose, six types of building materials (ready-mixed concrete, reinforcement steel, concrete bricks, glass, insulation, and gypsum for apartment buildings were selected as major building materials, and their inputs per unit area according to the structure types and plans of apartment buildings were derived by analyzing the design and bills of materials of 443 apartment buildings constructed in South Korea. In addition, a life-cycle scenario including the production, construction, maintenance, and end-of-life stage was constructed for each major building material. The EEIs of the apartment buildings were quantitatively assessed by applying the life-cycle inventory database (LCI DB and the Korean life-cycle impact assessment (LCIA method based on damage-oriented modeling (KOLID, and the results were analyzed.

  8. Extraction of water labeled with oxygen 15 during single-capillary transit. Influence of blood pressure, osmolarity, and blood-brain barrier damage

    International Nuclear Information System (INIS)

    Go, K.G.; Lammertsma, A.A.; Paans, A.M.; Vaalburg, W.; Woldring, M.G.

    1981-01-01

    By external detection, the influence of arterial blood pressure (BP), osmolarity, and cold-induced blood-brain barrier damage was assessed on the extraction of water labeled with oxygen 15 during single-capillary transit in the rat. There was an inverse relation between arterial BP and extraction that was attributable to the influence of arterial BP on cerebral blood flow (CBF) and the relation between CBF and extraction. Neither arterial BP nor osmolarity of the injected bolus had any direct effect on extraction of water 15O, signifying that the diffusional exchange component (determined by blood flow) of extraction greatly surpasses the convection flow contribution by hydrostatic or osmotic forces. Damage to the blood-brain barrier did not change its permeability to water

  9. NORTH PORTAL-HOT WATER CIRCULATION PUMP CALCULATION-SHOP BUILDING NO.5006

    International Nuclear Information System (INIS)

    Blackstone, R.

    1996-01-01

    The purpose of this design analysis and calculation is to size a circulating pump for the service hot water system in the Shop Building 5006, in accordance with the Uniform Plumbing Code (Section 4.4.1) and U.S. Department of Energy Order 6430.1A-1540 (Section 4.4.2). The method used for the calculation is based on Reference 5.2. This consists of determining the total heat transfer from the service hot water system piping to the surrounding environment. The heat transfer is then used to define the total pumping capacity based on a given temperature change in the circulating hot water as it flows through the closed loop piping system. The total pumping capacity is used to select a pump model from manufacturer's literature. This established the head generation for that capacity and particular pump model. The total length of all hot water supply and return piping including fittings is then estimated from the plumbing drawings which defines the pipe friction losses that must fit within the available pump head. Several iterations may be required before a pump can be selected that satisfies the head-capacity requirements

  10. ANALYSIS OF SUFFICIENCY OF THE BEARING CAPACITY OF BUILDING STRUCTURES OF OPERATING SITES OF MAIN BUILDINGS OF THERMAL POWER PLANTS

    Directory of Open Access Journals (Sweden)

    Alekseeva Ekaterina Leonidovna

    2012-10-01

    Full Text Available Upon examination of eleven main buildings of power plants, analysis of defects and damages of building structures was performed. Thereafter, the damageability of principal bearing structures of main buildings of thermal plants was analyzed. It was identified that the fastest growing defects and damages were concentrated in the structures of operating sites. The research of the rate of development of the most frequent damages and defects made it possible to conclude that internal corrosion of the reinforcing steel was the most dangerous defect, as far as the reinforced concrete elements of operating sites were concerned. Methods of mathematical statistics were applied to identify the reinforcing steel development pattern inside reinforced concrete elements of floors of operating sites. It was identified that the probability of corrosion of reinforced concrete elements of operating sites was distributed in accordance with the demonstrative law. Based on these data, calculation of strength of reinforced concrete slabs and metal beams was performed in terms of their regular sections, given the natural loads and the realistic condition of structures. As a result, dependence between the bearing capacity reserve ratio and the corrosion development pattern was identified for reinforced concrete slabs and metal beams of operating sites. In order to analyze the sufficiency of the bearing capacity of building structures of operating sites in relation to their time in commission, equations were derived to identify the nature of dependence between the sufficiency of the bearing capacity of reinforced concrete slabs and metal beams of the operating sites and their time in commission.

  11. Analysis of the Earthquake Impact towards water-based fire extinguishing system

    Science.gov (United States)

    Lee, J.; Hur, M.; Lee, K.

    2015-09-01

    Recently, extinguishing system installed in the building when the earthquake occurred at a separate performance requirements. Before the building collapsed during the earthquake, as a function to maintain a fire extinguishing. In particular, the automatic sprinkler fire extinguishing equipment, such as after a massive earthquake without damage to piping also must maintain confidentiality. In this study, an experiment installed in the building during the earthquake, the water-based fire extinguishing saw grasp the impact of the pipe. Experimental structures for water-based fire extinguishing seismic construction step by step, and then applied to the seismic experiment, the building appears in the extinguishing of the earthquake response of the pipe was measured. Construction of acceleration caused by vibration being added to the size and the size of the displacement is measured and compared with the data response of the pipe from the table, thereby extinguishing water piping need to enhance the seismic analysis. Define the seismic design category (SDC) for the four groups in the building structure with seismic criteria (KBC2009) designed according to the importance of the group and earthquake seismic intensity. The event of a real earthquake seismic analysis of Category A and Category B for the seismic design of buildings, the current fire-fighting facilities could have also determined that the seismic performance. In the case of seismic design categories C and D are installed in buildings to preserve the function of extinguishing the required level of seismic retrofit design is determined.

  12. Green Buildings and Health.

    Science.gov (United States)

    Allen, Joseph G; MacNaughton, Piers; Laurent, Jose Guillermo Cedeno; Flanigan, Skye S; Eitland, Erika Sita; Spengler, John D

    2015-09-01

    Green building design is becoming broadly adopted, with one green building standard reporting over 3.5 billion square feet certified to date. By definition, green buildings focus on minimizing impacts to the environment through reductions in energy usage, water usage, and minimizing environmental disturbances from the building site. Also by definition, but perhaps less widely recognized, green buildings aim to improve human health through design of healthy indoor environments. The benefits related to reduced energy and water consumption are well-documented, but the potential human health benefits of green buildings are only recently being investigated. The objective of our review was to examine the state of evidence on green building design as it specifically relates to indoor environmental quality and human health. Overall, the initial scientific evidence indicates better indoor environmental quality in green buildings versus non-green buildings, with direct benefits to human health for occupants of those buildings. A limitation of much of the research to date is the reliance on indirect, lagging and subjective measures of health. To address this, we propose a framework for identifying direct, objective and leading "Health Performance Indicators" for use in future studies of buildings and health.

  13. Building performance simulation as a design tool for refurbishment of buildings

    NARCIS (Netherlands)

    Hensen, J.L.M.; Bartak, M.; Drkal, F.; Dunovska, T.; Lain, M.; Matuska, T.; Schwarzer, J.; Sourek, B.; Bednar, T.

    2004-01-01

    This paper attempts to outline the current state-of-the-art regarding the use of building performance simulation as a design tool for refurbishment of buildings. This is illus-trated by means of three recent studies for conversion of historical buildings (an early 20th century factory, and a water

  14. Observations of Building Performance under Combined Wind and Surge Loading from Hurricane Harvey

    Science.gov (United States)

    Lombardo, F.; Roueche, D. B.; Krupar, R. J.; Smith, D. J.; Soto, M. G.

    2017-12-01

    Hurricane Harvey struck the Texas coastline on August 25, 2017, as a Category 4 hurricane - the first major hurricane to reach the US in twelve years. Wind gusts over 130 mph and storm surge as high as 12.5 ft caused widespread damage to buildings and critical infrastructure in coastal communities including Rockport, Fulton, Port Aransas and Aransas Pass. This study presents the methodology and preliminary observations of a coordinated response effort to document residential building performance under wind and storm surge loading. Over a twelve day survey period the study team assessed the performance of more than 1,000 individual, geo-located residential buildings. Assessments were logged via a smartphone application to facilitate rapid collection and collation of geotagged photographs, building attributes and structural details, and structural damage observations. Detailed assessments were also made of hazard intensity, specifically storm surge heights and both wind speed and direction indicators. Preliminary observations and findings will be presented, showing strong gradients in damage between inland and coastal regions of the affected areas that may be due in part to enhanced individual loading effects of wind and storm surge and potentially joint-hazard loading effects. Contributing factors to the many cases of disproportionate damage observed in close proximity will also be discussed. Ongoing efforts to relate building damage to near-surface hazard measurements (e.g., radar, anemometry) in close proximity will also be described.

  15. Use of EMW radiation in the building industry at defects in buildings

    Directory of Open Access Journals (Sweden)

    Sobotka Jindřich

    2017-01-01

    Full Text Available This paper discusses theory and application of microwave radiation and experimental optimization of microwave radiation to eliminate moisture content in wood elements. It will be appreciated that the rising moisture leaking into the structure, resulting in defects and structures of the buildings themselves. Owing to its properties, microwave radiation has been used in the construction industry in modern times, in particular to dry wet masonry of buildings. Effects of electromagnetic radiation on building structures lead to relatively sharp decreases in moisture content from damp building structures or elements. The influence of electromagnetic radiation on building structures lead to oscillation of water molecules contained in the material, which cause a phase transformation of water into vapour. Consequently, the vapour evaporates from the moist material, thereby drying the element exposed to radiation. The article describes experiments carried out at the Faculty of Civil Engineering of the Faculty of Technology in Brno that demonstrate successful decrease of water content in building materials using microwave radiation. First, the understanding of microwave radiation will be discussed. Following an analysis of research results an optimum intensity of microwave radiation sources as well as the necessary length of the irradiation of microwave radiation have been determined with respect to the particular type of building material and the success rate of elimination of moisture.

  16. Potential application of a centralized solar water-heating system for a high-rise residential building in Hong Kong

    International Nuclear Information System (INIS)

    Chow, T.T.; Fong, K.F.; Chan, A.L.S.; Lin, Z.

    2006-01-01

    There is a growing, government-led trend of applying renewable energy in Hong Kong. One area of interest lies in the wider use of solar-energy systems. The worldwide fast development of building-integrated solar technology has prompted the design alternative of fixing the solar panels on the external facades of buildings. In Hong Kong, high-rise buildings are found everywhere in the urban districts. How to make full use of the vertical facades of these buildings to capture the most solar radiation can be an important area in the technology promotion. In this numerical study, the potential application of a centralized solar water-heating system in high-rise residence was evaluated. Arrays of solar thermal collectors, that occupied the top two-third of the south and west facades of a hypothetical high-rise residence, were proposed for supporting the domestic hot-water system. Based on typical meteorological data, it was found that the annual efficiency of the vertical solar collectors could reach 38.4% on average, giving a solar fraction of 53.4% and a payback period of 9.2 years. Since the solar collectors were able to reduce the heat transmission through the building envelope, the payback was in fact even shorter if the energy saving in air-conditioner operation was considered

  17. Contribution of insurance data to cost assessment of coastal flood damage to residential buildings: insights gained from Johanna (2008) and Xynthia (2010) storm events

    OpenAIRE

    C. André; D. Monfort; M. Bouzit; C. Vinchon

    2013-01-01

    There are a number of methodological issues involved in assessing damage caused by natural hazards. The first is the lack of data, due to the rarity of events and the widely different circumstances in which they occur. Thus, historical data, albeit scarce, should not be neglected when seeking to build ex-ante risk management models. This article analyses the input of insurance data for two recent severe coastal storm events, to examine what causal relationships may exist bet...

  18. Changes in respiratory and non-respiratory symptoms in occupants of a large office building over a period of moisture damage remediation attempts.

    Science.gov (United States)

    Park, Ju-Hyeong; Cho, Sook Ja; White, Sandra K; Cox-Ganser, Jean M

    2018-01-01

    There is limited information on the natural history of building occupants' health in relation to attempts to remediate moisture damage. We examined changes in respiratory and non-respiratory symptoms in 1,175 office building occupants over seven years with multiple remediation attempts. During each of four surveys, we categorized participants using a severity score: 0 = asymptomatic; 1 = mild, symptomatic in the last 12 months, but not frequently in the last 4 weeks; 2 = severe, symptomatic at least once weekly in the last 4 weeks. Building-related symptoms were defined as improving away from the building. We used random intercept models adjusted for demographics, smoking, building tenure, and microbial exposures to estimate temporal changes in the odds of building-related symptoms or severity scores independent of the effect of microbial exposures. Trend analyses of combined mild/severe symptoms showed no changes in the odds of respiratory symptoms but significant improvement in non-respiratory symptoms over time. Separate analyses showed increases in the odds of severe respiratory symptoms (odds ratio/year = 1.15‒1.16, p-values<0.05) and severity scores (0.02/year, p-values<0.05) for wheezing and shortness of breath on exertion, due to worsening of participants in the mild symptom group. For non-respiratory symptoms, we found no changes in the odds of severe symptoms but improvement in severity scores (-0.04‒-0.01/year, p-values<0.05) and the odds for mild fever and chills, excessive fatigue, headache, and throat symptoms (0.65-0.79/year, p-values<0.05). Our study suggests that after the onset of respiratory and severe non-respiratory symptoms associated with dampness/mold, remediation efforts might not be effective in improving occupants' health.

  19. THE SOLUTION TO THE PROBLEM OF USING GROUND WATER TO COOL LIVESTOCK BUILDINGS

    Directory of Open Access Journals (Sweden)

    Thay Ngok Shon

    2017-01-01

    Full Text Available Ambient temperature in the central part of Vietnam in summer can reach 32–35°C; in some places it can be more than 42°C. Hot climate strongly affects the animal organism alongside with the animal weight reduction and reduction the quantity of egg-laying in poultry. Therefore, air conditioning in livestock buildings is necessary. There are several ways to cool the temperature in such buildings, and each one has its own advantages and disadvantages. We propose to use underground water at the temperature of 24–25°C for this purpose. One of the methods of cooling sheds for livestock is sprinkler irrigation of water on the roof. For calculating the amount of heat, removed from the indoor air in the shed to the cooling water, in the first approximation specialists believe in some cases that an appropriate amount of heat being removed is determined mainly by heat transfer from the air inside the shed to the cooling water through the surface of the roof, represented by the lower part of the wave that form the surface of a metal tile, neglecting the influence of heat conduction on top of the wave of the tile surface. Consequentially, such a simplification leads to possible errors. Therefore, the authors solved the problem of cooling shed by irrigation of water on the roof by an analytical method. Specifically, we solved the problem of heat conductivity of the fin of the finite length of constant cross section, wherein different sides of the fin are conjugate with different environments. Additionally, the calculation considered the effect of solar radiation. For this purpose, the authors have created a heat balance equation at steady state for any infinitesimal element of the fin, and solved the differential equation afterwards. The authors applied the results for calculating practical problem of ground water irrigation of a roof of a livestock shed made of metal areas tiles. 

  20. On the occurrence of rainstorm damage based on home insurance and weather data

    Directory of Open Access Journals (Sweden)

    M. H. Spekkers

    2015-02-01

    Full Text Available Rainstorm damage caused by the malfunction of urban drainage systems and water intrusion due to defects in the building envelope can be considerable. Little research on this topic focused on the collection of damage data, the understanding of damage mechanisms and the deepening of data analysis methods. In this paper, the relative contribution of different failure mechanisms to the occurrence of rainstorm damage is investigated, as well as the extent to which these mechanisms relate to weather variables. For a case study in Rotterdam, the Netherlands, a property level home insurance database of around 3100 water-related damage claims was analysed. The records include comprehensive transcripts of communication between insurer, insured and damage assessment experts, which allowed claims to be classified according to their actual damage cause. The results show that roof and wall leakage is the most frequent failure mechanism causing precipitation-related claims, followed by blocked roof gutters, melting snow and sewer flooding. Claims related to sewer flooding were less present in the data, but are associated with significantly larger claim sizes than claims in the majority class, i.e. roof and wall leakages. Rare events logistic regression analysis revealed that maximum rainfall intensity and rainfall volume are significant predictors for the occurrence probability of precipitation-related claims. Moreover, it was found that claims associated with rainfall intensities smaller than 7–8 mm in a 60-min window are mainly related to failure processes in the private domain, such as roof and wall leakages. For rainfall events that exceed the 7–8 mm h−1 threshold, the failure of systems in the public domain, such as sewer systems, start to contribute considerably to the overall occurrence probability of claims. The communication transcripts, however, lacked information to be conclusive about to which extent sewer-related claims were caused by

  1. The subsurface hydrology around Building 9201-2: Results of the July 1994 water level recovery test, Oak Ridge Y-12 plant, Oak Ridge, Tennessee

    International Nuclear Information System (INIS)

    1996-06-01

    A water level recovery test was conducted at Building 9201-2 at the Oak Ridge Y-12 Plant in Oak Ridge, Tennessee, from 12:45 p.m. on July 29 until 8:22 a.m. on July 31, 1994. The purpose of the test was to improve the general understanding of the subsurface hydrology around the building. The information is needed to determine the minimum pumping capacity necessary to maintain safe water levels in the basement of the building and to assist in designing systems for treating mercury-bearing waters in the basement. The test was initiated by shutting off the three main sump pumps in Building 9201-2 (i.e., O-12, E-13, and E-22) for 43.5 hr and allowing the water in the basement to approach a static level. The pumps in sumps F-3 and P-6 were also not operating during the test. During the test, water levels were monitored in 5 sumps (P-6, O-12, F-3, E-13, and E-22); a pit near sump K-22; 4 monitoring wells or piezometers in the basement near the O-12 sump, and 16 wells outside of the building. Sump K-22 was dry during the entire test

  2. Self-Healing Characteristics of Damaged Rock Salt under Different Healing Conditions

    Directory of Open Access Journals (Sweden)

    Lin Li

    2013-08-01

    Full Text Available Salt deposits are commonly regarded as ideal hosts for geologic energy reservoirs. Underground cavern construction-induced damage in salt is reduced by self-healing. Thus, studying the influencing factors on such healing processes is important. This research uses ultrasonic technology to monitor the longitudinal wave velocity variations of stress-damaged rock salts during self-recovery experiments under different recovery conditions. The influences of stress-induced initial damage, temperature, humidity, and oil on the self-recovery of damaged rock salts are analyzed. The wave velocity values of the damaged rock salts increase rapidly during the first 200 h of recovery, and the values gradually increase toward stabilization after 600 h. The recovery of damaged rock salts is subjected to higher initial damage stress. Water is important in damage recovery. The increase in temperature improves damage recovery when water is abundant, but hinders recovery when water evaporates. The presence of residual hydraulic oil blocks the inter-granular role of water and restrains the recovery under triaxial compression. The results indicate that rock salt damage recovery is related to the damage degree, pore pressure, temperature, humidity, and presence of oil due to the sealing integrity of the jacket material.

  3. Drivers of flood damage on event level

    DEFF Research Database (Denmark)

    Kreibich, H.; Aerts, J. C. J. H.; Apel, H.

    2016-01-01

    Flood risk is dynamic and influenced by many processes related to hazard, exposure and vulnerability. Flood damage increased significantly over the past decades, however, resulting overall economic loss per event is an aggregated indicator and it is difficult to attribute causes to this increasing...... trend. Much has been learned about damaging processes during floods at the micro-scale, e.g. building level. However, little is known about the main factors determining the amount of flood damage on event level. Thus, we analyse and compare paired flood events, i.e. consecutive, similar damaging floods...... example are the 2002 and 2013 floods in the Elbe and Danube catchments in Germany. The 2002 flood caused the highest economic damage (EUR 11600 million) due to a natural hazard event in Germany. Damage was so high due to extreme flood hazard triggered by extreme precipitation and a high number...

  4. Reduction of skin damage from transcutaneous oxygen electrodes using a spray on dressing.

    Science.gov (United States)

    Evans, N J; Rutter, N

    1986-09-01

    A spray on, copolymer acrylic dressing (Op-Site) was used to limit the skin damage caused by a transcutaneous oxygen electrode and its adhesive ring. Two identical electrodes were applied to the abdominal skin of 10 preterm infants, one on untreated skin, the other after application of Op-Site. It was found that Op-Site prevented the epidermal damage (as measured by transepidermal water loss) that occurs when the adhesive ring is removed from untreated skin. It did not interfere with transcutaneous oxygen measurements; absolute values and response times were unchanged. Op-Site is therefore useful in preventing the skin trauma that occurs when transcutaneous oxygen monitoring is being performed in preterm infants below 30 weeks' gestation in the first week of life. Care must be taken, however, to prevent a build up of Op-Site--it should be applied as a single layer, allowed to dry, and removed after use.

  5. Building America Case Study: Assessment of a Hybrid Retrofit Gas Water Heater

    Energy Technology Data Exchange (ETDEWEB)

    2017-06-19

    This project completed a modeling evaluation of a hybrid gas water heater that combines a reduced capacity tankless unit with a downsized storage tank. This product would meet a significant market need by providing a higher efficiency gas water heater solution for retrofit applications while maintaining compatibility with the half-inch gas lines and standard B vents found in most homes. The TRNSYS simulation tool was used to model a base case 0.60 EF atmospheric gas storage water, a 0.82 EF non-condensing gas tankless water heater, an existing (high capacity) hybrid unit on the market, and an alternative hybrid unit with lower storage volume and reduced gas input requirements. Simulations were completed under a 'peak day' sizing scenario with 183 gpd hot water loads in a Minnesota winter climate case. Full-year simulations were then completed in three climates (ranging from Phoenix to Minneapolis) for three hot water load scenarios (36, 57, and 96 gpd). Model projections indicate that the alternative hybrid offers an average 4.5% efficiency improvement relative to the 0.60 EF gas storage unit across all scenarios modeled. The alternative hybrid water heater evaluated does show promise, but the current low cost of natural gas across much of the country and the relatively small incremental efficiency improvement poses challenges in initially building a market demand for the product.

  6. Analysis of building deformation in landslide area using multisensor PSInSAR™ technique.

    Science.gov (United States)

    Ciampalini, Andrea; Bardi, Federica; Bianchini, Silvia; Frodella, William; Del Ventisette, Chiara; Moretti, Sandro; Casagli, Nicola

    2014-12-01

    Buildings are sensitive to movements caused by ground deformation. The mapping both of spatial and temporal distribution, and of the degree of building damages represents a useful tool in order to understand the landslide evolution, magnitude and stress distribution. The high spatial resolution of space-borne SAR interferometry can be used to monitor displacements related to building deformations. In particular, PSInSAR technique is used to map and monitor ground deformation with millimeter accuracy. The usefulness of the above mentioned methods was evaluated in San Fratello municipality (Sicily, Italy), which was historically affected by landslides: the most recent one occurred on 14th February 2010. PSInSAR data collected by ERS 1/2, ENVISAT, RADARSAT-1 were used to study the building deformation velocities before the 2010 landslide. The X-band sensors COSMO-SkyMed and TerraSAR-X were used in order to monitor the building deformation after this event. During 2013, after accurate field inspection on buildings and structures, damage assessment map of San Fratello were created and then compared to the building deformation velocity maps. The most interesting results were obtained by the comparison between the building deformation velocity map obtained through COSMO-SkyMed and the damage assessment map. This approach can be profitably used by local and Civil Protection Authorities to manage the post-event phase and evaluate the residual risks.

  7. Assessment of seismic damages in nuclear power plant buildings

    International Nuclear Information System (INIS)

    Corsanego, A.; DelGrosso, A.; Ferro, G.

    1987-01-01

    Performance of nuclear power plant sites, buildings and components is in today's practice continuously evaluated by means of monitoring systems composed by a variety of instruments, allowing records of the most significant behavioral parameters to be gathered by electronic data acquisition equipment. A great emphasis has been devoted in recent years to the development of ''intelligent'' monitoring systems able to perform interpretation of the response of structures and components automatically, only requiring human intervention and sophisticated data processing techniques when degradation of the safety margins is likely to have been produced. Such computerized procedures can be formulated through logic or algorithmic processes and normally are consistently based upon simplified, heuristic behavioral models and probabilistic reasoning schemes. This paper is devoted to discuss the development of an algorithmic procedure intended for automatic, real-time interpretation of the recorded response of nuclear power plant buildings and foundations during seismic events

  8. Prevalence of Legionella pneumophila in water distribution systems in hospitals and public buildings of the Lublin region of eastern Poland

    Directory of Open Access Journals (Sweden)

    Agnieszka Sikora

    2015-05-01

    The water samples collected form the hot water supply system of hospitals and public buildings showed exceeded counts of L. pneumophila, indicating the risk of infection. The constant monitoring of water distribution systems is an important element of the control of infections caused by these organisms.

  9. Effects of light emitting diode (LED) therapy and cold water immersion therapy on exercise-induced muscle damage in rats.

    Science.gov (United States)

    Camargo, Mariana Zingari; Siqueira, Cláudia Patrícia Cardoso Martins; Preti, Maria Carla Perozim; Nakamura, Fábio Yuzo; de Lima, Franciele Mendes; Dias, Ivan Frederico Lupiano; Toginho Filho, Dari de Oliveira; Ramos, Solange de Paula

    2012-09-01

    The aim of this work is to analyze the effects of LED therapy at 940 nm or cold water immersion therapy (CWI) after an acute bout of exercise on markers of muscle damage and inflammation. Thirty-two male Wistar rats were allocated into four groups: animals kept at rest (control), exercised animals (E), exercised + CWI (CWI), and exercised + LED therapy (LED). The animals swam for 100 min, after which blood samples were collected for lactate analysis. Animals in the E group were returned to their cages without treatment, the CWI group was placed in cold water (10°C) for 10 min and the LED group received LED irradiation on both gastrocnemius muscles (4 J/cm(2) each). After 24 h, the animals were killed and the soleus muscles were submitted to histological analysis. Blood samples were used for hematological and CK analyses. The results demonstrated that the LED group presented fewer areas of muscle damage and inflammatory cell infiltration and lower levels of CK activity than the E group. Fewer areas of damaged muscle fiber were observed in the LED group than in CWI. CWI and LED did not reduce edema areas. Hematological analysis showed no significant effect of either treatment on leukocyte counts. The results suggest that LED therapy is more efficient than CWI in preventing muscle damage and local inflammation after exercise.

  10. Overview of the Westinghouse Small Modular Reactor building layout

    Energy Technology Data Exchange (ETDEWEB)

    Cronje, J. M. [Westinghouse Electric Company LLC, Centurion (South Africa); Van Wyk, J. J.; Memmott, M. J. [Westinghouse Electric Company LLC, Cranberry Township, PA (United States)

    2012-07-01

    The Westinghouse Small Modular Reactor (SMR) is an 800 MWt (>225 MWe) integral pressurized water reactor (iPWR), in which all of the components typically associated with the nuclear steam supply system (NSSS) of a nuclear power plant are incorporated within a single reactor pressure vessel. This paper is the third in a series of four papers, which describe the design and functionality of the Westinghouse SMR. It focuses in particular upon the plant building layout and modular design of the Westinghouse SMR. In the development of small modular reactors, the building layout is an area where the safety of the plant can be improved by applying new design approaches. This paper will present an overview of the Westinghouse SMR building layout and indicate how the design features improve the safety and robustness of the plant. The Westinghouse SMR is designed with no shared systems between individual reactor units. The main buildings inside the security fence are the nuclear island, the rad-waste building, the annex building, and the turbine building. All safety related equipment is located in the nuclear island, which is a seismic class 1 building. To further enhance the safety and robustness of the design, the reactor, containment, and most of the safety related equipment are located below grade on the nuclear island. This reduces the possibility of severe damage from external threats or natural disasters. Two safety related ultimate heat sink (UHS) water tanks that are used for decay heat removal are located above grade, but are redundant and physically separated as far as possible for improved safety. The reactor and containment vessel are located below grade in the center of the nuclear island. The rad-waste and other radioactive systems are located on the bottom floors to limit the radiation exposure to personnel. The Westinghouse SMR safety trains are completely separated into four unconnected quadrants of the building, with access between quadrants only allowed

  11. Hydrophobization by Means of Nanotechnology on Greek Sandstones Used as Building Facades

    Directory of Open Access Journals (Sweden)

    Georgios Karagiannis

    2013-01-01

    Full Text Available Modern sustainable architecture indicates the use of local natural stones for building. Greek sandstones from Epirus (Demati, Greece, EN 12440 used as building facades meet aesthetic and have high mechanical properties, but the inevitable interaction between stone materials and natural or anthropogenic weathering factors controls the type, and extent of stone damages. In the present paper, samples of sandstone were treated with a conventional hydrophobic product and four solutions of the same product, enriched with nanosilica of different concentrations. The properties of the treated samples, such as porosity and pore size distribution, microstructure, static contact angle of a water droplet, and durability to deterioration cycles (freeze-thaw were recorded and conclusions were drawn. The research indicates the increased hydrophobic properties in nanosilica solutions but also the optimum content in nanoparticles that provides hydrophobicity without altering the properties of the stone.

  12. Legionellosis prevention in building water and HVAC systems a practical guide for design, operation and maintenance to minimize the risk

    CERN Document Server

    Joppolo, Cesare Maria; Pitera, Luca Alberto; Angermann, Jean Pierre; Izard, Mark

    2013-01-01

    This Guidebook is a practical guide for design, operation and maintenance to minimize the risk of legionellosis in building water and HVAC systmes. It is devided into several themes such as: Air conditioning of the air (by water – humidification), Production of hot water for washing (fundamentally but not only hot water for washing) and Evaporative cooling tower.

  13. Decreased bio-inhibition of building materials due to transport of biocides

    NARCIS (Netherlands)

    Erich, S.J.F.; Mendoza, S.M.; Floor, W.; Hermanns, S.P.M.; Homan, W.J.; Adan, O.C.G.

    2011-01-01

    Bio-inhibition of buildings and structures is an important issue. In many cases building materials have biocides added to prevent growth of micro-organisms. Growth of microorganisms on building materials has several negative effects; (1) Aesthetic damage, e.g. fungi, algae grow on the material,

  14. Risk-targeted safety distance of reinforced concrete buildings from natural-gas transmission pipelines

    International Nuclear Information System (INIS)

    Russo, Paola; Parisi, Fulvio

    2016-01-01

    Natural-gas pipeline accidents mostly result in major damage even to buildings located far away. Therefore, proper safety distances should be observed in land use planning to ensure target safety levels for both existing and new buildings. In this paper, a quantitative risk assessment procedure is presented for the estimation of the annual probability of direct structural damage to reinforced concrete buildings associated with high-pressure natural-gas pipeline explosions. The procedure is based on Monte Carlo simulation and takes into account physical features of blast generation and propagation, as well as damage to reinforced concrete columns. The natural-gas jet release process and the flammable cloud size are estimated through SLAB one-dimensional integral model incorporating a release rate model. The explosion effects are evaluated by a Multi-Energy Method. Damage to reinforced concrete columns is predicted by means of pressure–impulse diagrams. The conditional probability of damage was estimated at multiple pressure–impulse levels, allowing blast fragility surfaces to be derived at different performance limit states. Finally, blast risk was evaluated and allowed the estimation of minimum pipeline-to-building safety distances for risk-informed urban planning. The probabilistic procedure presented herein may be used for performance-based design/assessment of buildings and to define the path of new natural-gas pipeline networks. - Highlights: • The safety of buildings against blast loads due to pipeline accidents is assessed. • A probabilistic risk assessment procedure is presented for natural-gas pipelines. • The annual risk of collapse of reinforced concrete building columns is evaluated. • Monte Carlo simulation was carried out considering both pipeline and column features. • A risk-targeted safety distance is proposed for blast strength class 9.

  15. Mechanical Assessment of Fire Damage of the Ancient Greek Temple of Marble Stone

    OpenAIRE

    山田, 眞生

    2016-01-01

    Historical masonry heritages buildings existing in earthquake-prone countries have been affected many times by earthquakes in their long histories. The Parthenon, Athens in Greece is one of the most famous buildings, and it well known that the Parthenon was damaged seriously by earthquakes and especially human disasters. Therefore, restoration works have been performed carefully since 1975. In addition, marble stone constructions, for example marble column, also suffered serious damage by two...

  16. Use of the water supply system of special purpose in buildings

    Directory of Open Access Journals (Sweden)

    Orlov Evgeniy Vladimirovich

    Full Text Available A water supply system of a special purpose is a necessary element in hot and cold shops of the industrial enterprises, office buildings and the medical centers, and also other rooms. The water supply systems of a special purpose, which give subsalty, sparkling water and water sated with oxygen, allow people to prevent, for example, strong dehydration of an organism, which is possible at big losses of water, especially in case of the people working in hot shops. Various elements of special drinking water supply system are given in the article, their main functions are described. Different types of the water folding devices pumping water to consumers, one of which is drinking fountain, are considered. Possible systems of water filtration, which can be established for quality improvement, are transferred. Among them the great role is played by membrane technologies and the return osmosis, which is widely applied now. Today there is a possibility of construction, both the centralized water supply system of a special purpose, and local. Besides, the least is a more preferable option taking into account capital expenditure for construction and operation, and also it can lead to solid resource-saving as a result of the electric energy saving going for water heating in heaters. Automatic machines of drinking water for a local water supply system of a special purpose have indisputable advantages. They are capable to carry out several functions at the same time, and also to distribute water to consumers. It allows placing all the necessary equipment, which will be well in harmony with the environment in their small and compact case, and will fit into any difficult interior of the room. Also they are very easily connected to the systems of an internal water supply system by means of a propylene tube that allows to change their sposition in space and to transfer to any place of the room with fast installation of equipment. Also the ecological effect was

  17. The Importance of Damage Potential for Avalanche Risk Assessments

    Science.gov (United States)

    Keiler, M.; Fuchs, S.

    2003-04-01

    Risk is normally expressed as a function of recurrence probability of a process and its related damage potential. Various physical and empirical models describing the process aspect of the risk formula exist in the field of avalanche risk management while studies on damage potential are rare. Due to the changes of the socio-economic structures in mountain regions (urban sprawl, population growth, increased mobility and tourism) these studies are mandatory. This study focuses on different possibilities to obtain obligatory input parameters for multitemporal studies in settlement areas. A conceptual method that records the damage potential (probability of presence, evaluation of buildings) was developed and applied in Tyrol, Austria. A second approach, working with real-time insurance values for buildings and population growth, was tested in Grison, Switzerland. The different developments of the damage potential in the two alpine study areas are highlighted; their influences on the risk formula are discussed. The results of both studies show the advantages and disadvantages of each method, such as precision, amount of time needed and possibilities of implementing in a GIS. The results serve to improve risk determination and point out an unnoticed increase of damage potential and risk in apparently safe settlement areas.

  18. Shockless spalling damage of alumina ceramic

    Science.gov (United States)

    Erzar, B.; Buzaud, E.

    2012-05-01

    Ceramic materials are commonly used to build multi-layer armour. However reliable test data is needed to identify correctly models and to be able to perform accurate numerical simulation of the dynamic response of armour systems. In this work, isentropic loading waves have been applied to alumina samples to induce spalling damage. The technique employed allows assessing carefully the strain-rate at failure and the dynamic strength. Moreover, specimens have been recovered and analysed using SEM. In a damaged but unbroken specimen, interactions between cracks has been highlighted illustrating the fragmentation process.

  19. Evaluation and demonstration of decentralized space and water heating versus centralized services for new and rehabilitated multifamily buildings. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Belkus, P. [Foster-Miller, Inc., Waltham, MA (US); Tuluca, A. [Steven Winter Associates, Inc., Norwalk, CT (US)

    1993-06-01

    The general objective of this research was aimed at developing sufficient technical and economic know-how to convince the building and design communities of the appropriateness and energy advantages of decentralized space and water heating for multifamily buildings. Two main goals were established to guide this research. First, the research sought to determine the cost-benefit advantages of decentralized space and water heating versus centralized systems for multifamily applications based on innovative gas piping and appliance technologies. The second goal was to ensure that this information is made available to the design community.

  20. Molecular models for DNA damaged by photoreaction

    International Nuclear Information System (INIS)

    Pearlman, D.A.; Holbrook, S.R.; Pirkle, D.H.; Kim, S.H.

    1985-01-01

    Structural models of a DNA molecule containing a radiation-induced psoralen cross-link and of a DNA containing a thymine photodimer were constructed by applying energy-minimization techniques and model-building procedures to data from x-ray crystallographic studies. The helical axes of the models show substantial kinking and unwinding at the sites of the damage, which may have long-range as well as local effects arising from the concomitant changes in the supercoiling and overall structure of the DNA. The damaged areas may also serve as recognition sites for repair enzymes. These results should help in understanding the biologic effects of radiation-induced damage on cells

  1. Convenient methods for appreciating effects of acid rain on stone building materials; Sekizai ni taisuru sanseiu no eikyo hyokaho no kento

    Energy Technology Data Exchange (ETDEWEB)

    Katami, T.; Takahara, Y.; Nishikawa, H.; Kato, K. [Gifu Prefectural Health and Environmental Research Center, Gifu (Japan)

    1996-05-10

    A method to evaluate effects of acid rain has been investigated by exposing building marble plates at both outdoor and indoor sites and measuring lightness and roughness on the surface of plates. The lower pH of rain water fell, the more remarkable loss of lightness appeared in a short period on the surface of outdoor samples in one to three months exposure tests. As an appropriate negative correlation was shown between the lightness and the pH value, it was found that physical change of the plate surface can be estimated by using the lightness, optically measured value. For three to nine months indoor-exposure tests, difference of the lightness were quantitatively observed, but little differences of the roughness height were recognized among the different exposure sites. From the reduction of lightness on the marble plate surface exposed at outdoor and indoor sites, it was also found that damage levels of the marble plates were four to eleven times higher at outdoor sites by rain water than those at indoor sites by air pollutants, such as acid gases, in the ambient air. Thus, the optical method may be useful to evaluate damage levels of marble building materials caused by acid-rain water after exposing them for a relatively short period. 10 refs., 3 figs., 6 tabs.

  2. Calculation of coal power plant cost on agricultural and material building impact of emission

    International Nuclear Information System (INIS)

    Mochamad Nasrullah; Wiku Lulus Widodo

    2016-01-01

    Calculation for externally cost of Coal Power Plant (CPP) is very important. This paper is focus on CPP appear SO 2 impact on agricultural plant and material building. AGRIMAT'S model from International Atomic Energy Agency is model one be used to account environmental damage for air impact because SO 2 emission. Analysis method use Impact Pathways Assessment: Determining characteristic source, Exposure Response Functions (ERF), Impacts and Damage Costs, and Monetary Unit Cost. Result for calculate shows that SO 2 that issued CPP, if value of SO 2 is 19,3 μg/m3, damage cost begins valuably positive. It shows that the land around CPP has decrease prosperity, and it will disadvantage for agricultural plant. On material building, SO 2 resulting damage cost. The increase humidity price therefore damage cost on material building will increase cost. But if concentration SO 2 increase therefore damage cost that is appear on material building decrease. Expected this result can added with external cost on health impact of CPP. External cost was done at developed countries. If it is done at Indonesia, therefore generation cost with fossil as more expensive and will get implication on issue cut back gases greenhouse. On the other side, renewable energy and also alternative energy as nuclear have opportunity at national energy mix system. (author)

  3. Bellanca building, Yellowknife : building envelope retrofit project

    Energy Technology Data Exchange (ETDEWEB)

    Rajewski, G. [A.D. Williams Engineering Inc., Edmonton, AB (Canada)

    2008-07-01

    The Bellanca building is a ten-story, commercial office building, located in Yellowknife, Northwest Territories. The owner was concerned about annual fuel consumption, relative to other buildings of similar size. Tenants reported cold drafts and some ice build-up had been reported in the past, on the exterior of the cladding. In addition, some water penetration had occurred during rainfall. This presentation provided background information on the Bellanca building and discussed a building envelope retrofit project. A.D. Williams was hired in late 2006 in order to provide an opinion on the present condition of the building envelope. This presentation described the site investigation and presented an interior and exterior review of the building. It also presented a thermographic survey in order to map thermal anomalies and establish trends. Following acceptance of the report on findings, one of five options was selected for further development. This included removal of existing cladding, exterior gypsum wallboard, fiberglass insulation and application of BASF Walltite CT foam, sheathing, rigid insulation, drainage plane and new cladding. The preliminary design was then presented. This paper also described the tender and award of the contract; construction phase; and substantial completion of the project. tabs, figs.

  4. A Study to Compare the Cost of Operation and Maintenance in Green Building Index (GBI and Non-Green Building Index (Non-GBI Rated Building in Malaysia

    Directory of Open Access Journals (Sweden)

    Ping Lee Zheng

    2016-01-01

    Full Text Available Urges for sustainable development had pushed the government and professional bodies to respond and react by implementing regulations where possible to direct development in that manner. However, the outcome in most financial conferences and dialogues on sustainable buildings flagged on high construction and maintenance cost. Thus, this study is conducted to collect and analyze actual building operation and maintenance cost between GBI and Non-GBI rated buildings in Malaysia which are more than 2 years fully operated buildings. There are two categories of selected buildings which are residential and non-residential type of building. Each category of the building consists of similar building’s characteristic such as geographic location, mode of operation, building heights, total numbers of floors and units. The scope of building’s maintenance for this study is mainly on wear and tear of the wall painting, electrical light fittings, ceiling panels, roofing system and mechanical services like water pump system are recorded for their replacement frequency of service and the cost involved within a consistent period of 12 months operation at cost percentage saving of 78.9% and 40.4% for residential and non-residential buildings respectively compare against Non-GBI rated buildings. Electricity consumption for GBI rated buildings are lower than Non-GBI rated buildings which recorded at the cost variance of 23.8% and 6.3% and water consumption at 35.9% and 44.0% for the above mentioned two main categories of selected case study buildings. Results from this study conclude major savings on residential buildings category in term of maintenance cost and electricity consumption for GBI rated buildings. Whereby, non-residential category of buildings, GBI rated building had been proven to obtain significant savings in terms of maintenance cost and water consumption.

  5. Synthesis of water soluble CdS nanoparticles and study of their DNA damage activity

    Directory of Open Access Journals (Sweden)

    Kumar Suranjit Prasad

    2017-05-01

    Full Text Available This study reports a novel method for preparation of water soluble CdS nanoparticles using leaf extract of a plant, Asparagus racemosus. The extract of the leaf tissue which worked as a stabilizing and capping agent, assisted the formation of nanoparticles. Nanoparticles were characterized using a UV–vis spectrophotometer, Photoluminescence, TEM, EDAX, XRD and FT-IR. Transmission electron microscopy followed by selected area electron diffraction pattern analysis indicated the formation of spherical, polydispersed, crystalline, CdS of diameter ranging from 2 to 8 nm. X-ray diffraction studies showed the formation of 111, 220 and 311 planes of face-centered cubic (fcc CdS. EDAX analysis confirmed the presence of Cd and S in nanosphere. The cytotoxicity test using MTT assay as well as DNA damage analysis using comet assay revealed that synthesized nano CdS quantum dots (QDs caused less DNA damage and cell death of lymphocytes than pure CdS nanoparticles.

  6. Comparison of european computer codes relative to the aerosol behavior in PWR containment buildings during severe core damage accidents. (Modelling of steam condensation on the particles)

    International Nuclear Information System (INIS)

    Bunz, H.; Dunbar, L.H.; Fermandjian, J.; Lhiaubet, G.

    1987-11-01

    An aerosol code comparison exercise was performed within the framework of the Commission of European Communities (Division of Safety of Nuclear Installations). This exercise, focused on the process of steam condensation onto the aerosols occurring in PWR containment buildings during severe core damage accidents, has allowed to understand the discrepancies between the results obtained. These discrepancies are due, in particular, to whether the curvature effect is modelled or not in the codes

  7. The alkaline comet assay used in evaluation of genotoxic damage of drinking water disinfection by-products (bromoform and chloroform

    Directory of Open Access Journals (Sweden)

    Messaouda Khallef

    2015-06-01

    Full Text Available The alkaline comet assay (pH 12.3 is a useful method for monitoring genotoxic effects of environmental pollutants in the root nuclei of Allium cepa and various plants; it allows the detection of single- and double-strand breaks, incomplete excision-repair sites and cross-links. It has been introduced to detect even small changes in DNA structure. It is a technically simple, highly sensitive, fast and economic test which detects in vitro and in vivo genotoxicity (DNA integrity and packing mode in any cell types examined, and requires just a few cells for its execution (Liman et al., 2011; Yıldız et al., 2009. Chloroform and bromoform are the most important trihalomethanes found in drinking water. Different concentrations of bromoform (25, 50, 75and 100µg/ml and chloroform (25, 50, 100 and 200 µg/ml were introduced to onion tuber roots. Distilled water was used as a negative control and methyl methansulfonate (MMS-10 µg/ml as positive control. All obtained data were subjected to statistical analyses by using SPSS 15.0 for Windows software. For comparison purposes, Duncan multiple range tests using one-way analysis of variance (ANOVA were employed and p<0.05 was accepted as the test of significance. Comet assay results showed that DNA damage was significant at p <0.05 for the different concentrations of chloroform and bromoform compared to the negative control which has a damage rate equal to 3.5 ± 0.7 and the positive control which has damage rate equal to 13.5 ± 2.12. The exposure of root tip cells to these disinfection by-products increases DNA damage. All concentrations examined in this study of bromoform and chloroform cause significant harm, which could be due to DNA damage induced by oxidative stress. The measurement of DNA damage in the nuclei of higher plant tissues is a new area of study with SCGE. This assay could be incorporated into in situ monitoring of atmosphere, water and soil: the comet assay allows a fast detection without

  8. The design procedures on brick building against surface ground deformations due to mining and earthquake

    Energy Technology Data Exchange (ETDEWEB)

    Zhong, J.; Yang, S. (China University of Mining and Technology (China))

    1992-05-01

    By analysing the effects of ground motion and deformation on surface buildings, and drawing on the experience of damages caused by the Tangshan and Chenhai earthquakes, the authors discuss the design of brick and concrete buildings which are protected against the damaging effects of both earthquakes and mining activities. 5 figs.

  9. DETECTION OF COLLAPSED BUILDINGS BY CLASSIFYING SEGMENTED AIRBORNE LASER SCANNER DATA

    Directory of Open Access Journals (Sweden)

    S. O. Elberink

    2012-09-01

    Full Text Available Rapid mapping of damaged regions and individual buildings is essential for efficient crisis management. Airborne laser scanner (ALS data is potentially able to deliver accurate information on the 3D structures in a damaged region. In this paper we describe two different strategies how to process ALS point clouds in order to detect collapsed buildings automatically. Our aim is to detect collapsed buildings using post event data only. The first step in the workflow is the segmentation of the point cloud detecting planar regions. Next, various attributes are calculated for each segment. The detection of damaged buildings is based on the values of these attributes. Two different classification strategies have been applied in order to test whether the chosen strategy is capable of detect- ing collapsed buildings. The results of the classification are analysed and assessed for accuracy against a reference map in order to validate the quality of the rules derived. Classification results have been achieved with accuracy measures from 60–85% complete- ness and correctness. It is shown that not only the classification strategy influences the accuracy measures; also the validation meth- odology, including the type and accuracy of the reference data, plays a major role.

  10. Economic measurement of environment damages

    Energy Technology Data Exchange (ETDEWEB)

    Krawiec, F.

    1980-05-01

    The densities, energy consumption, and economic development of the increasing population exacerbate environmental degradation. Air and water pollution is a major environmental problem affecting life and health, outdoor recreation, household soiling, vegetation, materials, and production. The literature review indicated that numerous studies have assessed the physical and monetary damage to populations at risk from excessive concentrations of major air and water pollutants-sulfur dioxide, total suspended particulate matter, oxidants, and carbon monoxide in air; and nutrients, oil, pesticides, and toxic metals and others in water. The measurement of the damages was one of the most controversial issues in pollution abatement. The methods that have been used to estimate the societal value of pollution abatement are: (1) chain of effects, (2) market approaches, and (3) surveys. National gross damages of air pollution of $20.2 billion and of water pollution of $11.1 billion for 1973 are substantial. These best estimates, updated for the economic and demographic conditions, could provide acceptable control totals for estimating and predicting benefits and costs of abating air and water pollution emissions. The major issues to be resolved are: (1) lack of available noneconomic data, (2) theoretical and empirical difficulties of placing a value on human life and health and on benefits such as aesthetics, and (3) lack of available demographic and economic data.

  11. Bacterial amplification and in-place carpet drying: implications for category 1 water intrusion restoration.

    Science.gov (United States)

    Holland, Jim; Banta, John; Passmore, Boni; Ayers, Mark; Abbott, Sean P; Cole, Eugene C

    2012-05-01

    The study described in this article investigated whether in-place carpet drying processes resulted in bacterial amplification following water intrusion from a clean water source (category 1) in a residential indoor environment. Bacterial amplification was examined after wetting a 10-year-old carpet and pad that had no history of water intrusion. Three test areas were extracted and dried using industry-recommended procedures for in-place drying and compared to a control area that was not extracted or dried. Results from carpet, pad, and subsurface dust demonstrated that bacterial amplification occurred in all test areas. CFUs of bacteria per gram of carpet surface dust and subsurface dust prior to water intrusion were lower than levels in subsurface dust after in-place drying. The authors' study contributes to information regarding the restoration of water-based carpet damage by professional water damage restoration companies, building maintenance personnel, and housekeeping managers. Results suggest that the appropriate response time for carpet pad salvage is considerably shorter than the current industry recommendation of 72 hours.

  12. Towards Coupling of Macroseismic Intensity with Structural Damage Indicators

    Science.gov (United States)

    Kouteva, Mihaela; Boshnakov, Krasimir

    2016-04-01

    Knowledge on basic data of ground motion acceleration time histories during earthquakes is essential to understanding the earthquake resistant behaviour of structures. Peak and integral ground motion parameters such as peak ground motion values (acceleration, velocity and displacement), measures of the frequency content of ground motion, duration of strong shaking and various intensity measures play important roles in seismic evaluation of existing facilities and design of new systems. Macroseismic intensity is an earthquake measure related to seismic hazard and seismic risk description. Having detailed ideas on the correlations between the earthquake damage potential and macroseismic intensity is an important issue in engineering seismology and earthquake engineering. Reliable earthquake hazard estimation is the major prerequisite to successful disaster risk management. The usage of advanced earthquake engineering approaches for structural response modelling is essential for reliable evaluation of the accumulated damages in the existing buildings and structures due to the history of seismic actions, occurred during their lifetime. Full nonlinear analysis taking into account single event or series of earthquakes and the large set of elaborated damage indices are suitable contemporary tools to cope with this responsible task. This paper presents some results on the correlation between observational damage states, ground motion parameters and selected analytical damage indices. Damage indices are computed on the base of nonlinear time history analysis of test reinforced structure, characterising the building stock of the Mediterranean region designed according the earthquake resistant requirements in mid XX-th century.

  13. Structural damage

    International Nuclear Information System (INIS)

    Gray, R.E.; Bruhn, R.W.

    1992-01-01

    Virtually all structures show some signs of distress due to deterioration of the building components, to changed loads, or to changed support conditions. Changed support conditions result from ground movements. In mining regions many cases of structural distress are attributed to mining without considering alternative causes. This is particularly true of coal mining since it occurs under extensive areas. Coal mining is estimated to have already undermined more than eight million acres and may eventually undermine 40 million acres in the United States. Other nonmetal and metal underground mines impact much smaller areas. Although it is sometimes difficult, even with careful study, to identify the actual cause of damage, persons responsible for underground coal mining should at least be aware of possible causes of building stress other than mine subsidence. This paper presents information on distress to structures and briefly reviews a number of causes of ground movements other than subsidence: Mass movements, dissolution, erosion, frost action, shrinking and swelling, yield into excavations and compressibility

  14. Radiation-induced DNA damage as a function of DNA hydration

    International Nuclear Information System (INIS)

    Swarts, S.G.; Miao, L.; Wheeler, K.T.; Sevilla, M.D.; Becker, D.

    1995-01-01

    Radiation-induced DNA damage is produced from the sum of the radicals generated by the direct ionization of the DNA (direct effect) and by the reactions of the DNA with free radicals formed in the surrounding environment (indirect effect). The indirect effect has been believed to be the predominant contributor to radiation-induced intracellular DNA damage, mainly as the result of reactions of bulk water radicals (e.g., OH·) with DNA. However, recent evidence suggests that DNA damage, derived from the irradiation of water molecules that are tightly bound in the hydration layer, may occur as the result of the transfer of electron-loss centers (e.g. holes) and electrons from these water molecules to the DNA. Since this mechanism for damaging DNA more closely parallels that of the direct effect, the irradiation of these tightly bound water molecules may contribute to a quasi-direct effect. These water molecules comprise a large fraction of the water surrounding intracellular DNA and could account for a significant proportion of intracellular radiation-induced DNA damage. Consequently, the authors have attempted to characterize this quasi-direct effect to determine: (1) the extent of the DNA hydration layer that is involved with this effect, and (2) what influence this effect has on the types and quantities of radiation-induced DNA damage

  15. Risks in the transport and storage of liquefied natural gas. Sub-project 5-2: Investigation into building damage

    Science.gov (United States)

    Gouwens, C.; Dragosavic, M.

    The large reserves and increasing use of natural gas as a source of energy have resulted in its storage and transport becoming an urgent problem. Since a liquid of the same mass occupies only a fraction of the volume of a gas, it is economical to store natural gas as a liquid. Liquefied natural gas is stored in insulated tanks and also carried by ship at a temperature of -160 C to 170 C. If a serious accident allows the LNG to escape, a gas cloud forms. The results of a possible explosion from such a gas cloud are studied. The development of a leak, escape and evaporation, size and propagation of the gas cloud, the explosive pressures to be expected and the results on the environment are investigated. Damage to buildings is examined making use of the preliminary conclusions of the other sub-projects and especially the explosive pressures.

  16. Application of petrographic examination techniques to the assessment of fire-damaged concrete and masonry structures

    International Nuclear Information System (INIS)

    Ingham, Jeremy P.

    2009-01-01

    The number of building fires has doubled over the last 50 years. There has never been a greater need for structures to be assessed for fire damage to ensure safety and enable appropriate repairs to be planned. Fortunately, even after a severe fire, concrete and masonry structures are generally capable of being repaired rather than demolished. By allowing direct examination of microcracking and mineralogical changes, petrographic examination has become widely used to determine the depth of fire damage for reinforced concrete elements. Petrographic examination can also be applied to fire-damaged masonry structures built of materials such as stone, brick and mortar. Petrography can ensure accurate detection of damaged geomaterials, which provides cost savings during building repair and increased safety reassurance. This paper comprises a review of the role of petrography in fire damage assessments, drawing on a range of actual fire damage investigations.

  17. DNA damage and oxidative stress in human liver cell L-02 caused by surface water extracts during drinking water treatment in a waterworks in China.

    Science.gov (United States)

    Xie, Shao-Hua; Liu, Ai-Lin; Chen, Yan-Yan; Zhang, Li; Zhang, Hui-Juan; Jin, Bang-Xiong; Lu, Wen-Hong; Li, Xiao-Yan; Lu, Wen-Qing

    2010-04-01

    Because of the daily and life-long exposure to disinfection by-products formed during drinking water treatment, potential adverse human health risk of drinking water disinfection is of great concern. Toxicological studies have shown that drinking water treatment increases the genotoxicity of surface water. Drinking water treatment is comprised of different potabilization steps, which greatly influence the levels of genotoxic products in the surface water and thus may alter the toxicity and genotoxicity of surface water. The aim of the present study was to understand the influence of specific steps on toxicity and genotoxicity during the treatment of surface water in a water treatment plant using liquid chlorine as the disinfectant in China. An integrated approach of the comet and oxidative stress assays was used in the study, and the results showed that both the prechlorination and postchlorination steps increased DNA damage and oxidative stress caused by water extracts in human derived L-02 cells while the tube settling and filtration steps had the opposite effect. This research also highlighted the usefulness of an integrated approach of the comet and oxidative stress assays in evaluating the genotoxicity of surface water during drinking water treatment. Copyright 2009 Wiley-Liss, Inc.

  18. The Perception of Small Scale Damage and Repairs of Natural Stone

    NARCIS (Netherlands)

    Quist, W.; Van Hees, R.; Naldin, S.; Nijland, T.

    2008-01-01

    By means of a questionnaire a study was carried out to investigate the perception of small scale damage and repairs of natural stone used in buildings. Participants were asked to evaluate damage to natural stone shown on pictures. They were also asked to give their opinion on interventions needed to

  19. Seismic vulnerability and damage of Italian historical centres: A case study in the Campania region

    Science.gov (United States)

    Formisano, Antonio; Chieffo, Nicola; Fabbrocino, Francesco; Landolfo, Raffaele

    2017-07-01

    The preservation of masonry buildings typical of Italian historical centres represents a very pressing dilemma founded on recovery need of the urban fabric original character. In the paper, based on a methodology developed by some of the Authors on building aggregates, the seismic vulnerability estimation of some masonry compounds in the heart of the town of San PotitoSannitico (Caserta, Italy) is presented and compared to the results achieved from applying the basic literature method for isolated constructions. Finally, the damage scenario of inspected buildings has been shown by highlighting clearly the influence of different positions of structural units on the damages that masonry aggregates suffer under different grade earthquakes, leading to individuate the most vulnerable buildings.

  20. Nest-building behavior of Monk Parakeets and insights into potential mechanisms for reducing damage to utility poles

    Directory of Open Access Journals (Sweden)

    Kevin R. Burgio

    2014-09-01

    Full Text Available The Monk Parakeet (Myiopsitta monachus commonly uses utility poles as a substrate for building large, bulky nests. These nests often cause fires and electric power outages, creating public safety risks and increasing liability and maintenance costs for electric companies. Previous research has focused on lethal methods and chemical contraception to prevent nesting on utility poles and electrical substations. However, implementation of lethal methods has led to public protests and lawsuits, while chemical contraception may affect other than the targeted species, and must be continually reapplied for effectiveness. One non-lethal alternative, nest removal, is costly and may not be a sustainable measure if Monk Parakeet populations continue to grow. In order to identify cost-effective non-lethal solutions to problems caused by Monk Parakeet nesting, we studied their behavior as they built nests on utility poles. Monk Parakeets initiate nests by attaching sticks at the intersection of the pole and electric lines. We found that parakeets use the electric lines exclusively to gain access to the intersection of lines and pole during nest initiation, and continue to use the lines intensively throughout construction. Monk Parakeets also have more difficulty attaching sticks during the early stages of nest construction than when the nest is nearing completion. These findings suggest that intervention during the earlier stages of nest building, by excluding Monk Parakeets from electric lines adjacent to poles, may be an effective, non-lethal method of reducing or eliminating parakeets nesting on, and damaging, utility poles.

  1. Computer aided seismic and fire retrofitting analysis of existing high rise reinforced concrete buildings

    CERN Document Server

    Hussain, Raja Rizwan; Hasan, Saeed

    2016-01-01

    This book details the analysis and design of high rise buildings for gravity and seismic analysis. It provides the knowledge structural engineers need to retrofit existing structures in order to meet safety requirements and better prevent potential damage from such disasters as earthquakes and fires. Coverage includes actual case studies of existing buildings, reviews of current knowledge for damages and their mitigation, protective design technologies, and analytical and computational techniques. This monograph also provides an experimental investigation on the properties of fiber reinforced concrete that consists of natural fibres like coconut coir and also steel fibres that are used for comparison in both Normal Strength Concrete (NSC) and High Strength Concrete (HSC). In addition, the authors examine the use of various repair techniques for damaged high rise buildings. The book will help upcoming structural design engineers learn the computer aided analysis and design of real existing high rise buildings ...

  2. Stingless bees damage broccoli inflorescences when collecting fibers for nest building

    Directory of Open Access Journals (Sweden)

    Adriano Jorge Nunes dos Santos

    2012-01-01

    Full Text Available The stingless bee Trigona spinipes (Fabricius, 1793 (Hymenoptera: Apidae is an important pollinator for various crops, but constitutes an occasional pest of other plant species since it causes injury to leaves, stems, flowers and fruits while collecting nest materials. The aim of the present study was to determine the damage caused by T. spinipes to a broccoli (Brassica oleracea L. var. italica, Brassicaceae growing on an organic farm. A significant number of plants (72.5 % presented damaged inflorescences, while 39% of all of the inflorescences suffered some degree of injury. The activities of T. spinipes caused scarifications on the stems of the inflorescences, and these typically evolved to epidermal cicatrices up to 10 mm wide. In some cases, the lesions were sufficiently deep to cause partial destruction of the vascular tissues, and this lead to thinner (< 5 mm diameter floral stems that may collapse. To the best of our knowledge, this is the first report concerning the attack of broccoli plants by T. spinipes. The results obtained should serve to highlight the possibility that stingless bees could be responsible for direct and/or indirect damage to vegetable crops, and to stimulate the development of control strategies for these incidental pests.

  3. Detection of multiple damages employing best achievable eigenvectors under Bayesian inference

    Science.gov (United States)

    Prajapat, Kanta; Ray-Chaudhuri, Samit

    2018-05-01

    A novel approach is presented in this work to localize simultaneously multiple damaged elements in a structure along with the estimation of damage severity for each of the damaged elements. For detection of damaged elements, a best achievable eigenvector based formulation has been derived. To deal with noisy data, Bayesian inference is employed in the formulation wherein the likelihood of the Bayesian algorithm is formed on the basis of errors between the best achievable eigenvectors and the measured modes. In this approach, the most probable damage locations are evaluated under Bayesian inference by generating combinations of various possible damaged elements. Once damage locations are identified, damage severities are estimated using a Bayesian inference Markov chain Monte Carlo simulation. The efficiency of the proposed approach has been demonstrated by carrying out a numerical study involving a 12-story shear building. It has been found from this study that damage scenarios involving as low as 10% loss of stiffness in multiple elements are accurately determined (localized and severities quantified) even when 2% noise contaminated modal data are utilized. Further, this study introduces a term parameter impact (evaluated based on sensitivity of modal parameters towards structural parameters) to decide the suitability of selecting a particular mode, if some idea about the damaged elements are available. It has been demonstrated here that the accuracy and efficiency of the Bayesian quantification algorithm increases if damage localization is carried out a-priori. An experimental study involving a laboratory scale shear building and different stiffness modification scenarios shows that the proposed approach is efficient enough to localize the stories with stiffness modification.

  4. LANL seismic screening method for existing buildings

    International Nuclear Information System (INIS)

    Dickson, S.L.; Feller, K.C.; Fritz de la Orta, G.O.

    1997-01-01

    The purpose of the Los Alamos National Laboratory (LANL) Seismic Screening Method is to provide a comprehensive, rational, and inexpensive method for evaluating the relative seismic integrity of a large building inventory using substantial life-safety as the minimum goal. The substantial life-safety goal is deemed to be satisfied if the extent of structural damage or nonstructural component damage does not pose a significant risk to human life. The screening is limited to Performance Category (PC) -0, -1, and -2 buildings and structures. Because of their higher performance objectives, PC-3 and PC-4 buildings automatically fail the LANL Seismic Screening Method and will be subject to a more detailed seismic analysis. The Laboratory has also designated that PC-0, PC-1, and PC-2 unreinforced masonry bearing wall and masonry infill shear wall buildings fail the LANL Seismic Screening Method because of their historically poor seismic performance or complex behavior. These building types are also recommended for a more detailed seismic analysis. The results of the LANL Seismic Screening Method are expressed in terms of separate scores for potential configuration or physical hazards (Phase One) and calculated capacity/demand ratios (Phase Two). This two-phase method allows the user to quickly identify buildings that have adequate seismic characteristics and structural capacity and screen them out from further evaluation. The resulting scores also provide a ranking of those buildings found to be inadequate. Thus, buildings not passing the screening can be rationally prioritized for further evaluation. For the purpose of complying with Executive Order 12941, the buildings failing the LANL Seismic Screening Method are deemed to have seismic deficiencies, and cost estimates for mitigation must be prepared. Mitigation techniques and cost-estimate guidelines are not included in the LANL Seismic Screening Method

  5. Hydrogen behavior in a large-dry pressurized water reactor containment building during a severe accident

    International Nuclear Information System (INIS)

    Hsu Wensheng; Chen Hungpei; Hung Zhenyu; Lin Huichen

    2014-01-01

    Following severe accidents in nuclear power plants, large quantities of hydrogen may be generated after core degradation. If the hydrogen is transported from the reactor vessel into the containment building, an explosion might occur, which might threaten the integrity of the building; this can ultimately cause the release of radioactive materials. During the Fukushima Daiichi nuclear accident in 2011, the primary containment structures remained intact but contaminated fragments broke off the secondary containment structures, which disrupted mitigation activities and triggered subsequent explosions. Therefore, the ability to predict the behavior of hydrogen after severe accidents may facilitate the development of effective nuclear reactor accident management procedures. The present study investigated the behavior of hydrogen in a large-dry pressurized water reactor (PWR). The amount of hydrogen produced was calculated using the Modular Accident Analysis Program. The hydrogen transport behavior and the effect of the explosion on the PWR containment building were simulated using the Flame Acceleration Simulator. The simulation results showed that the average hydrogen volume fraction is approximately 7% in the containment building and that the average temperature is 330 K. The maximum predicted pressure load after ignition is 2.55 bar, which does not endanger the structural integrity of the containment building. The results of this investigation indicate that the hydrogen mitigation system should be arranged on both the upper and lower parts of the containment building to reduce the impact of an explosion. (author)

  6. Co-exploring the Water-Energy-Food Nexus: Facilitating Dialogue through Participatory Scenario Building

    Directory of Open Access Journals (Sweden)

    Oliver W. Johnson

    2017-05-01

    Full Text Available The “water-energy-food nexus” has become an increasingly popular way to frame the challenges associated with reconciling human development objectives with responsible management of natural resources and ecosystems. Yet the nexus is complex, requiring effective engagement between expert and Non-expert stakeholders in order to understand biophysical inter-linkages between resources and resource flows and social interactions between different actors in the socio-ecological system and landscape. This can be a substantial challenge due to varying levels of knowledge and understanding amongst actors with divergent, and often entrenched, interests. This paper presents insights on how participatory scenario-building processes can create space for dialogue amongst stakeholders with differing knowledge, experience, priorities, and political perspectives. Drawing on completed and on-going research applying a “nexus toolkit” in Ethiopia and Rwanda respectively, we contribute to a generalized conceptual framework for addressing, communicating, and assessing the water-energy-food nexus, with a particular focus on how to utilize the nexus concept in practice. This framework has significant potential to help better understand interactions at landscape level, for example, between charcoal production, food production, and environmental systems. We find that participatory scenario-building processes that facilitate engagement beyond technical aspects to include social, economic and political concerns provide a valuable space for discussing and negotiating development pathways that are sustainable both biophysically and socio-economically. In addition, the involvement of stakeholders throughout the project process greatly enhances the quality and legitimacy of results. Furthermore, we suggest that by building capacity amongst stakeholders to maintain a quantitative “nexus toolkit,” it has a better chance of informing decision-making and for supporting

  7. Visualization and quantification of weathering effects on capillary water uptake of natural building stones by using neutron imaging

    International Nuclear Information System (INIS)

    Raneri, Simona; Barone, Germana; Mazzoleni, Paolo; Rabot, Eva

    2016-01-01

    Building stones are frequently subjected to very intense degradation due to salt crystallization, often responsible for strong modifications of their pore network. These effects have a great influence on the mechanical properties and durability of the materials, and on the penetration of water. Therefore, the quantification and visualization of water absorption into the pore network of degraded stones could provide useful information to better understand the weathering process. In this study, neutron radiography has been used (1) to monitor and visualize in two dimensions the capillary water uptake in a Sicilian calcarenite widely used as building and replace stone (namely Sabucina stone) and (2) to quantify the water content distribution, as a function of time and weathering degree. Additionally, traditional experiments based on gravimetric methods have been performed, following the standard recommendations. Results demonstrated a change in the physical properties of Sabucina stones with the intensification of the degradation process, with severe effects on the capillary imbibition dynamics. The water penetration depth at the end of the experiment was substantially higher in the fresh than in the weathered stones. The water absorption kinetics was faster in the weathered samples, and the amount of water absorbed increased with the number of weathering cycles. Good agreement between classical and neutron imaging data has also been evidenced. However, neutron radiography has allowed retrieving additional spatial information on the water absorption process, and to better understand how salt weathering affects the petrophysical properties of the studied stone and how it influences then the stone response against water. (orig.)

  8. Visualization and quantification of weathering effects on capillary water uptake of natural building stones by using neutron imaging

    Energy Technology Data Exchange (ETDEWEB)

    Raneri, Simona; Barone, Germana; Mazzoleni, Paolo [University of Catania, Department of Biological, Geological and Environment Sciences, Catania (Italy); Rabot, Eva [Laboratoire Leon Brillouin (CNRS/CEA), Gif-Sur-Yvette (France)

    2016-11-15

    Building stones are frequently subjected to very intense degradation due to salt crystallization, often responsible for strong modifications of their pore network. These effects have a great influence on the mechanical properties and durability of the materials, and on the penetration of water. Therefore, the quantification and visualization of water absorption into the pore network of degraded stones could provide useful information to better understand the weathering process. In this study, neutron radiography has been used (1) to monitor and visualize in two dimensions the capillary water uptake in a Sicilian calcarenite widely used as building and replace stone (namely Sabucina stone) and (2) to quantify the water content distribution, as a function of time and weathering degree. Additionally, traditional experiments based on gravimetric methods have been performed, following the standard recommendations. Results demonstrated a change in the physical properties of Sabucina stones with the intensification of the degradation process, with severe effects on the capillary imbibition dynamics. The water penetration depth at the end of the experiment was substantially higher in the fresh than in the weathered stones. The water absorption kinetics was faster in the weathered samples, and the amount of water absorbed increased with the number of weathering cycles. Good agreement between classical and neutron imaging data has also been evidenced. However, neutron radiography has allowed retrieving additional spatial information on the water absorption process, and to better understand how salt weathering affects the petrophysical properties of the studied stone and how it influences then the stone response against water. (orig.)

  9. A Conceptual Model for the Sustainable Governance of Integrated Management of National Water Resources with a Focus on Training and Capacity Building

    Directory of Open Access Journals (Sweden)

    Alaleh Ghaemi

    2017-09-01

    Full Text Available The instabilities over the past two decades in governing water resources have led to the need for an integrated approach to the problem. Moreover, the decent and sustainable governance of water resources has come to be recognized as the supplement to the integrated management of water resources. The present study strives to develop a conceptual model of water reources sustainable governance with emphasis on training and capacity-building. For this purpose, expert views presented to different international meetings and world conferences on water were reviewed to develop a comprehensive and all-embracuing conceptual model of sustainable governance for the integrated management of water resources with a focus on training and capacity-building. In a second stage of the study, both internationally published literature and the regulatory documents on water management approved at the national level were consulted to derive appropriate standards, criteria, and indicators for the implementation of the proposed conceptual model. The relevance of these indicators was validated by soliciting expert views while their stability was calculated via the Cronbach’s alpha formula to be 0.94. The third stage of the study involved the ranking and gradation of the indicators using the relevant software in a fuzzy decision-making environment based on interviews with 110 senior water executives, academics working in the field, senior agricultural managers, water experts in local communities, and NGO activists. The emerging model finally consisted of 9 criteria and 52 indicators, amongst which the criterion of public participation and the indicator of training and capacity-building won the highest scores. It may be claimed that the proposed conceptual model is quite relevant and adapted to the sustainable governance presently sought. The key roles in this model are played by public participation as well as training and capacity building that must be on the priority

  10. SEISMIC EVALUATION OF EXISTING MID-RISE REINFORCED CONCRETE BUILDINGS ACCORDING TO SPECIFICATION FOR BUILDING STRUCTURES TO BE BUILT IN DISASTER AREAS

    Directory of Open Access Journals (Sweden)

    Mehmet İNEL

    2007-01-01

    Full Text Available Over the past several decades, Turkey has been hit by devastating earthquakes and remarkable number of reinforced concrete buildings has been damaged in the high seismicity regions of our country. The aim of this study is to evaluate the seismic performance of the mid-rise reinforced concrete buildings that are major part of building stock of our earthquake-prone country, according to recent Turkish Earthquake Code. 4- and 7-story buildings were selected to represent mid-rise building stock. After determining the structural parameters, each building was subjected to pushover analysis and the capacity curves were obtained. Earthquake performance of each building was determined in the light of their capacity curves according to the recent Turkish Earthquake Code.

  11. A tool for the calculation of rockfall fragility curves for masonry buildings

    Science.gov (United States)

    Mavrouli, Olga

    2017-04-01

    Masonries are common structures in mountainous and coastal areas and they exhibit substantial vulnerability to rockfalls. For big rockfall events or precarious structures the damage is very high and the repair is not cost-effective. Nonetheless, for small or moderate rockfalls, the damage may vary in function of the characteristics of the impacting rock blocks and of the buildings. The evaluation of the expected damage for masonry buildings, and for different small and moderate rockfall scenarios, is useful for assessing the expected direct loss at constructed areas, and its implications for life safety. A tool for the calculation of fragility curves for masonry buildings which are impacted by rock blocks is presented. The fragility curves provide the probability of exceeding a given damage state (low, moderate and high) for increasing impact energies of the rock blocks on the walls. The damage states are defined according to a damage index equal to the percentage of the damaged area of a wall, as being proportional to the repair cost. Aleatoric and epistemic uncertainties are incorporated with respect to the (i) rock block velocity, (ii) rock block size, (iii) masonry width, and (iv) masonry resistance. The calculation of the fragility curves is applied using a Monte Carlo simulation. Given user-defined data for the average value of these four parameters and their variability, random scenarios are developed, the respective damage index is assessed for each scenario, and the probability of exceedance of each damage state is calculated. For the assessment of the damage index, a database developed by the results of 576 analytical simulations is used. The variables range is: wall width 0.4 - 1.0 m, wall tensile strength 0.1 - 0.6 MPa, rock velocity 1-20 m/s, rock size 1-20 m3. Nonetheless this tool permits the use of alternative databases, on the condition that they contain data that correlate the damage with the four aforementioned variables. The fragility curves can

  12. Building Philippine SMEs Resilience to Natural Disasters

    OpenAIRE

    Ballesteros, Marife M.; Domingo, Sonny N.

    2015-01-01

    Disasters are bad for business specifically for small and medium enterprises (SMEs). These catastrophic events can compromise capital, logistics, product market, and labor, which compromise business continuity and recovery. Physical damage and disruptions in supply and labor can cause temporary business closure while structural repairs to buildings and recovery or replacement of damaged equipment needed to restore operations require large amount of resources. The adverse impact may not only b...

  13. Effect of water deficit on leaf phenolic composition, gas exchange, oxidative damage and antioxidant activity of four Greek olive (Olea europaea L.) cultivars.

    Science.gov (United States)

    Petridis, Antonios; Therios, Ioannis; Samouris, Georgios; Koundouras, Stefanos; Giannakoula, Anastasia

    2012-11-01

    The olive tree (Olea europaea L.) is often exposed to severe water stress during the summer season. In this study, we determined the changes in total phenol content, oleuropein and hydroxytyrosol in the leaves of four olive cultivars ('Gaidourelia', 'Kalamon', 'Koroneiki' and 'Megaritiki') grown under water deficit conditions for two months. Furthermore, we investigated the photosynthetic performance in terms of gas exchange and chlorophyll a fluorescence, as well as malondialdehyde content and antioxidant activity. One-year-old self-rooted plants were subjected to three irrigation treatments that received a water amount equivalent to 100% (Control, C), 66% (Field Capacity 66%, FC(66)) and 33% (Field Capacity 33%, FC(33)) of field capacity. Measurements were conducted 30 and 60 days after the initiation of the experiment. Net CO(2) assimilation rate, stomatal conductance and F(v)/F(m) ratio decreased only in FC(33) plants. Photosynthetic rate was reduced mainly due to stomatal closure, but damage to PSII also contributed to this decrease. Water stress induced the accumulation of phenolic compounds, especially oleuropein, suggesting their role as antioxidants. Total phenol content increased in FC(33) treatment and oleuropein presented a slight increase in FC(66) and a sharper one in FC(33) treatment. Hydroxytyrosol showed a gradual decrease as water stress progressed. Malondialdehyde (MDA) content increased due to water stress, mostly after 60 days, while antioxidant activity increased for all cultivars in the FC(33) treatment. 'Gaidourelia' could be considered as the most tolerant among the tested cultivars, showing higher phenolic concentration and antioxidant activity and lower lipid peroxidation and photochemical damage after two months of water stress. The results indicated that water stress affected olive tree physiological and biochemical parameters and magnitude of this effect depended on genotype, the degree of water limitation and duration of treatment

  14. Economic losses to buildings due to tsunami impact: the case of Rhodes city, Greece

    Science.gov (United States)

    Triantafyllou, Ioanna; Novikova, Tatyana; Papadopoulos, Gerassimos

    2017-04-01

    The expected economic losses to buildings due to the tsunami impact is of particular importance for the tsunami risk management. However, only few efforts can be found in this direction. In this study we approached this issue selecting the city of Rhodes Isl., Greece, as a test-site. The methodological steps followed include (a) selection of worst case scenario in the study area based on the tsunami history of the area which includes several powerful events, e.g. 142 AD, 1303, 1481, 1609, 1741, (b) numerical simulation of the tsunami and determination of the inundation zone, (c) application of the DAMASCHE empirical tool, produced by the SCHEMA EU-FP6 project, for the calculation of the damage level expected at each one of the buildings as a function of the water depth in the inundation area, (d) calculation of the buildings that would need reparation after partial damage and of those that would need reconstruction after total destruction, (e) calculation of the cost implied for both reparation and reconstruction. The several data sets which are needed for the execution of these steps, are susceptible to uncertainties and, therefore, the final results are quite sensitive to changes of the data sets. Alternative costs were calculated by taking into account the several uncertainties involved. This research is a contribution to the EU-FP7 tsunami research project ASTARTE (Assessment, Strategy And Risk Reduction for Tsunamis in Europe), grant agreement no: 603839, 2013-10-30.

  15. Performance evaluation of an integrated solar water heater as an option for building energy conservation

    Energy Technology Data Exchange (ETDEWEB)

    Dharuman, C.; Arakeri, J.H.; Srinivasan, K. [Indian Inst. of Science, Bangalaore (India). Dept. of Mechanical Engineering

    2006-03-15

    Since a majority of residential and industrial building hot water needs are around 50 {sup o}C, an integrated solar water heater could provide a bulk source that blends collection and storage into one unit. This paper describes the design, construction and performance test results of one such water-heating device. The test unit has an absorber area of 1.3 m{sup 2} and can hold 170 l of water, of which extractable volume per day is 100 l. Its performance was evaluated under various typical operating conditions. Every morning at about 7:00 a.m., 100 l of hot water were drawn from the sump and replaced with cold water from the mains. Although, during most of the days, the peak temperatures of water obtained are between 50 and 60 {sup o}C, the next morning temperatures were lower at 45-50 {sup o}C. Daytime collection efficiencies of about 60% and overall efficiencies of about 40% were obtained. Tests were conducted with and without stratification. Night radiation losses were reduced by use of a screen insulation. (author)

  16. Bridging the Water Policy and Management Silos: An Opportunity for Leveraged Capacity Building

    Science.gov (United States)

    Wegner, D. L.

    2017-12-01

    The global community is challenged by increasing demand and decreasing water supplies. Historically nations have focused on local or regional water development projects that meet specific needs, often without consideration of the impact on downstream transboundary water users or the watershed itself. Often these decisions have been based on small sets of project specific data with little assessment on river basin impacts. In the United States this disjointed approach to water has resulted in 26 federal agencies having roles in water management or regulation, 50 states addressing water rights and compliance, and a multitude of tribal and local entities intersecting the water process. This approach often manifests itself in a convoluted, disjointed and time-consuming approach. The last systematic and comprehensive review of nationwide water policy was the 1973 National Water Commission Report. A need exists for capacity building collaborative and integrative leadership and dialogue. NASA's Western Water Applications Office (WWAO) provides a unique opportunity to leverage water and terrain data with water agencies and policy makers. A supported WWAO can provide bridges between federal and state water agencies; provide consistent integrated hydrologic and terrain based data set acquired from multiple earth orbiting satellites and airborne platforms; provide data sets leveraged with academic and research based entities to develop specific integrative predictive tools; and evaluate hydrology information across multiple boundaries. It is the author's conclusion that the Western Water Applications Office can provide a value-added approach that will help translate transboundary water and earth terrain information to national policy decisions through education, increased efficiency, increased connectivity, improved coordination, and increased communication. To be effective the WWAO should embrace five objectives: (1) be technically and scientifically valid; (2

  17. Water-cooled, fire boom blanket, test and evaluation for system prototype development

    International Nuclear Information System (INIS)

    Stahovec, J. G.; Urban, R. W.

    1999-01-01

    Initial development of actively cooled fire booms indicated that water-cooled barriers could withstand direct oil fire for several hours with little damage if cooling water were continuously supplied. Despite these early promising developments, it was realized that to build reliable full-scale system for Navy host salvage booms would require several development tests and lengthy evaluations. In this experiment several types of water-cooled fire blankets were tested at the Oil and Hazardous Materials Simulated Test Tank (OHMSETT). After the burn test the blankets were inspected for damage and additional tests were conducted to determine handling characteristics for deployment, recovery, cleaning and maintenance. Test results showed that water-cooled fire boom blankets can be used on conventional offshore oil containment booms to extend their use for controlling large floating-oil marine fires. Results also demonstrated the importance of using thermoset rubber coated fabrics in the host boom to maintain sufficient reserve seam strength at elevated temperatures. The suitability of passively cooled covers should be investigated to protect equipment and boom from indirect fire exposure. 1 ref., 2 tabs., 8 figs

  18. Seismic vulnerability: theory and application to Algerian buildings

    Science.gov (United States)

    Mebarki, Ahmed; Boukri, Mehdi; Laribi, Abderrahmane; Farsi, Mohammed; Belazougui, Mohamed; Kharchi, Fattoum

    2014-04-01

    When dealing with structural damages, under the effect of natural hazards such as earthquakes, it is still a scientific challenge to predict the potential damages, before occurrence of a given hazard, as well as to evaluate the damages once the earthquake has occurred. In the present study, two distinct methods addressing these topics are developed. Thousands (˜54,000) of existing buildings damaged during the Boumerdes earthquake that occurred in Algeria (Mw = 6.8, May 21, 2003) are considered in order to study their accuracy and sensitivity. Once an earthquake has occurred, quick evaluations of the damages are required in order to distinguish which structures should be demolished or evacuated immediately from those which can be kept in service without evacuation of its inhabitants. For this purpose, visual inspections are performed by trained and qualified engineers. For the case of Algeria, an evaluation form has been developed and is still in use since the early 80s: Five categories of damages are considered (no damage or very slight, slight, moderate, major, and very severe/collapse). This paper develops a theoretical methodology that processes the observed damages caused to the structural and nonstructural components (foundations, roofs, slabs, walls, beams, columns, fillings, partition walls, stairways, balconies, etc.), in order to help the evaluator to derive the global damage evaluation. This theoretical methodology transforms the damage category into a corresponding "residual" risk of failure ranging from zero (no damage) to one (complete damage). The global failure risk, in fact its corresponding damage category, is then derived according to given combinations of probabilistic events in order to express the influence of any component on the global damage and behavior. The method is calibrated on a set of ˜54,000 buildings inspected after Boumerdes earthquake. Almost 80 % of accordance (same damage category) is obtained, when comparing the theoretical

  19. Kinetics of water sorption of damaged bean grains: Thermodynamic properties

    Directory of Open Access Journals (Sweden)

    Paulo C. Corrêa

    Full Text Available ABSTRACT This study aims to determine the thermodynamic properties of damaged beans. Grains with initial moisture content of 53.85% (d.b. were used. A part of the grains was used to obtain the desorption isotherms, while another part was subjected to drying until a moisture content of 5.26% (d.b. was achieved; therefore, it was subjected to the adsorption process. To induce damage, a Stein breakage tester was used. To obtain the equilibrium moisture content, grains were placed in a climatic chamber whose temperatures were 20, 30, 40, and 50 ± 1 °C combined with a relative humidity of 30, 40, 50, 70, and 90 ± 3%. Although in the desorption process, damaged grains had a lower differential enthalpy compared with the control, the reverse behavior was observed in the adsorption process. Mechanical damage caused the formation of a greater number of available adsorption sites, resulting in higher differential entropy values in adsorption and lower values in desorption compared with the control. The mechanical damage had no effect on the Gibbs free energy.

  20. Bean grain hysteresis with induced mechanical damage

    Directory of Open Access Journals (Sweden)

    Renata C. Campos

    Full Text Available ABSTRACT This study aimed to evaluate the effect of mechanical damage on the hysteresis of beans with induced mechanical damage under different conditions of temperature and relative humidity. Beans (Phaseolus vulgaris L. harvested manually with 35% water content (w.b. were used. Part of this product was subjected to induced mechanical damage by Stein Breakage Tester and controlled drying (damaged and control sample, for sorption processes. The sorption isotherms of water were analyzed for different temperature conditions: 20, 30, 40 and 50 oC; and relative humidity: 0.3; 0.4; 0.5; 0.7 and 0.9 (decimal. Equilibrium moisture content data were correlated with six mathematical models, and the Modified Oswin model was the one that best fitted to the experimental data. According to the above mentioned isotherms, it was possible to observe the phenomenon of hysteresis of damaged and control samples, and this phenomenon was more pronounced in control ones.

  1. Estimation of core-damage frequency to evolutionary ALWR [advanced light water reactor] due to seismic initiating events: Task 4.3.3

    International Nuclear Information System (INIS)

    Brooks, R.D.; Harrison, D.G.; Summitt, R.L.

    1990-04-01

    The Electric Power Research Institute (EPRI) is presently developing a requirements document for the design of advanced light water reactors (ALWRs). One of the basic goals of the EPRI ALWR Requirements Document is that the core-damage frequency for an ALWR shall be less than 1.0E-5. To aid in this effort, the Department of Energy's Advanced Reactor Severe Accident Program (ARSAP) initiated a functional probabilistic risk assessment (PRA) to determine how effectively the evolutionary plant requirements contained in the existing EPRI Requirements Document assure that this safety goal will be met. This report develops an approximation of the core-damage frequency due to seismic events for both evolutionary plant designs (pressurized-water reactor (PWR) and boiling-water reactor(BWR)) as modeled in the corresponding functional PRAs. Component fragility values were taken directly form information which has been submitted for inclusion in Appendix A to Volume 1 of the EPRI Requirements Document. The results show a seismic core-damage frequency of 5.2E-6 for PWRS and 5.0E-6 for BWRs. Combined with the internal initiators from the functional PRAs, the overall core-damage frequencies are 6.0E-6 for the pwr and BWR, both of which satisfy the 1.0E-5 EPRI goal. In addition, site-specific considerations, such as more rigid components and less conservative fragility data and seismic hazard curves, may further reduce these frequencies. The effect of seismic events on structures are not addressed in this generic evaluation and should be addressed separately on a design-specific basis. 7 refs., 6 figs., 3 tabs

  2. Performance of precast buildings during Emilia-Romagna earthquakes: a case study

    OpenAIRE

    Ercolino, Marianna; Magliulo, Gennaro; Manfredi, Gaetano

    2015-01-01

    On May 2012 two earthquakes occurred in Emilia-Romagna region (Italy) causing several damages to existing industrial precast structures. These damages were mainly due to inadequate connection systems and the main recorded failures were the loss of support of structural elements due to the sliding of friction connections. This paper aims at justifying some of these damages by investigating the response of a real industrial building, located in Mirandola (Modena, Italy) and seriously damaged af...

  3. VVER operational experience - effect of preconditioning and primary water chemistry on radioactivity build-up

    International Nuclear Information System (INIS)

    Zmitko, M.; Kysela, J.; Dudjakova, K.; Martykan, M.; Janesik, J.; Hanus, V.; Marcinsky, P.

    2004-01-01

    The primary coolant technology approaches currently used in VVER units are reviewed and compared with those used in PWR units. Standard and modified water chemistries differing in boron-potassium control are discussed. Preparation of the VVER Primary Water Chemistry Guidelines in the Czech Republic is noted. Operational experience of some VVER units, operated in the Czech Republic and Slovakia, in the field of the primary water chemistry, and radioactivity transport and build-up are presented. In Mochovce and Temelin units, a surface preconditioning (passivation) procedure has been applied during hot functional tests. The main principles of the controlled primary water chemistry applied during the hot functional tests are reviewed and importance of the water chemistry, technological and other relevant parameters is stressed regarding to the quality of the passive layer formed on the primary system surfaces. The first operational experience obtained in the course of beginning of these units operation is presented mainly with respect to the corrosion products coolant and surface activities. Effect of the initial passivation performed during hot functional tests and the primary water chemistry on corrosion products radioactivity level and radiation situation is discussed. (author)

  4. BREEAM [Building Research Establishment Environmental Assessment Method] BRE [Building Research Establishment] assessment method for buildings

    International Nuclear Information System (INIS)

    Baldwin, R.

    1994-01-01

    Buildings account for a large share of environmental impacts in their construction, use, and demolition. In western Europe, buildings account for ca 50% of primary energy use (hence CO 2 output), far outweighing the contribution of the transport and industrial sectors. Other impacts from building energy use include the use of chemicals such as chlorofluorocarbons for cooling. In the United Kingdom, the Building Research Establishment (BRE) has developed a certificate system for environmental labelling of buildings so that the performance of the building against a set of defined environmental criteria can be made visible to clients. This system thus rewards positive actions to improve the environmental performance of buildings and assists in marketing to an environmentally aware clientele. Issues included in assessments for awarding the certificate are addressed under three main headings: global issues and use of resources, local issues, and indoor issues. Global issues include ozone depletion and CO 2 emissions; local issues include public health and water conservation; and indoor issues include air quality and lighting. 8 refs., 1 tab

  5. Probabilistic Damage Stability Calculations for Ships

    DEFF Research Database (Denmark)

    Jensen, Jørgen Juncher

    1996-01-01

    The aim of these notes is to provide background material for the present probabilistic damage stability rules fro dry cargo ships.The formulas for the damage statistics are derived and shortcomings as well as possible improvements are discussed. The advantage of the definiton of fictitious...... compartments in the formulation of a computer-based general procedure for probabilistic damaged stability assessment is shown. Some comments are given on the current state of knowledge on the ship survivability in damaged conditions. Finally, problems regarding proper account of water ingress through openings...

  6. Estimation of Damage Costs Associated with Flood Events

    Science.gov (United States)

    Andrews, T. A.; Wauthier, C.; Zipp, K.

    2017-12-01

    This study investigates the possibility of creating a mathematical function that enables the estimation of flood-damage costs. We begin by examining the costs associated with past flood events in the United States. The data on these tropical storms and hurricanes are provided by the National Oceanic and Atmospheric Administration. With the location, extent of flooding, and damage reparation costs identified, we analyze variables such as: number of inches rained, land elevation, type of landscape, region development in regards to building density and infrastructure, and population concentration. We seek to identify the leading drivers of high flood-damage costs and understand which variables play a large role in the costliness of these weather events. Upon completion of our mathematical analysis, we turn out attention to the 2017 natural disaster of Texas. We divide the region, as we did above, by land elevation, type of landscape, region development in regards to building density and infrastructure, and population concentration. Then, we overlay the number of inches rained in those regions onto the divided landscape and apply our function. We hope to use these findings to estimate the potential flood-damage costs of Hurricane Harvey. This information is then transformed into a hazard map that could provide citizens and businesses of flood-stricken zones additional resources for their insurance selection process.

  7. Insect Pests and Integrated Pest Management in Museums, Libraries and Historic Buildings.

    Science.gov (United States)

    Querner, Pascal

    2015-06-16

    Insect pests are responsible for substantial damage to museum objects, historic books and in buildings like palaces or historic houses. Different wood boring beetles (Anobium punctatum, Hylotrupes bajulus, Lyctus sp. or introduced species), the biscuit beetle (Stegobium paniceum), the cigarette beetle (Lasioderma serricorne), different Dermestides (Attagenus sp., Anthrenus sp., Dermestes sp., Trogoderma sp.), moths like the webbing clothes moth (Tineola bisselliella), Silverfish (Lepisma saccharina) and booklice (Psocoptera) can damage materials, objects or building parts. They are the most common pests found in collections in central Europe, but most of them are distributed all over the world. In tropical countries, termites, cockroaches and other insect pests are also found and result in even higher damage of wood and paper or are a commune annoyance in buildings. In this short review, an introduction to Integrated Pest Management (IPM) in museums is given, the most valuable collections, preventive measures, monitoring in museums, staff responsible for the IPM and chemical free treatment methods are described. In the second part of the paper, the most important insect pests occurring in museums, archives, libraries and historic buildings in central Europe are discussed with a description of the materials and object types that are mostly infested and damaged. Some information on their phenology and biology are highlighted as they can be used in the IPM concept against them.

  8. Unfolding Urban Geographies of Water-Related Vulnerability and Inequalities: Recognising Risks in Knowledge Building in Lima, Peru

    NARCIS (Netherlands)

    Miranda Sara, L.; Pfeffer, K.; Baud, I.; Bell, S.; Allen, A.; Hofmann, P.; Teh, T.-H.

    2017-01-01

    This chapter analyses how different discourses influence knowledge-building processes in terms of their main concerns, water sector boundaries, and types of information considered legitimate, in the context of Lima. It shows how these processes are embedded in urban configurations, and how the

  9. Tornado Protection: Selecting and Designing Safe Areas in Buildings.

    Science.gov (United States)

    Abernethy, James J.

    Tornadoes and extreme winds cause heavy loss of life and property damage throughout the United States. Most buildings offer significant protection from this danger, and building administrators should know the areas where this protection is available. This booklet presents a review of three schools, all of which were struck by tornadoes on April 3,…

  10. Mould growth prediction by computational simulation on historic buildings

    OpenAIRE

    Krus, M.; Kilian, R.; Sedlbauer, K.

    2007-01-01

    Historical buildings are often renovated with a high expenditure of time and money without investigating and considering the causes of the damages. In many cases historic buildings can only be maintained by changing their usage. This change of use may influence the interior climate enormously. To assess the effect on the risk of mould growth on building parts or historic monuments a predictive model has been developed recently, describing the hygrothermal behaviour of the spore. It allows for...

  11. Probability Assessment and Risk Management of Progressive Collapse in Strategic Buildings Facing Blast Loads

    Directory of Open Access Journals (Sweden)

    Gholamreza Abdollahzadeh

    2016-12-01

    Full Text Available Nowadays, as a result of increased terrorist and bomb attacks throughout the globe in the vicinity of strategic buildings, designing these structures against impact loads, particularly the blast-related ones, has been taken into more consideration. The current procedure for designing the structure against an explosion is a design against the local failure of the current elements in the first step and then, in the next step, against local damage as well as tactful thinking to prevent this damage from spreading to other parts of the structure. The present research investigates the impacts of explosives, derived from probable terror–stricken scenarios inside and outside a strategic four-story steel building with a special moment frame system. Then, the resistive capacity of the damaged building (due to blast has been evaluated against the progressive collapse, and finally, the rate of the collapse risk and the reliability of the structure have been obtained by presenting a probable method. Thus, the vulnerable parts inside and outside the building are identified and safety measures have been determined, so that in case of no safety or excessive collapse risk- access to dangerous parts of the building could be reinforced or limited. Results show that progressive collapse probability and reliability of the building are 57% and 43% respectively.

  12. On the Influence of Input Data Quality to Flood Damage Estimation: The Performance of the INSYDE Model

    Directory of Open Access Journals (Sweden)

    Daniela Molinari

    2017-09-01

    Full Text Available IN-depth SYnthetic Model for Flood Damage Estimation (INSYDE is a model for the estimation of flood damage to residential buildings at the micro-scale. This study investigates the sensitivity of INSYDE to the accuracy of input data. Starting from the knowledge of input parameters at the scale of individual buildings for a case study, the level of detail of input data is progressively downgraded until the condition in which a representative value is defined for all inputs at the census block scale. The analysis reveals that two conditions are required to limit the errors in damage estimation: the representativeness of representatives values with respect to micro-scale values and the local knowledge of the footprint area of the buildings, being the latter the main extensive variable adopted by INSYDE. Such a result allows for extending the usability of the model at the meso-scale, also in different countries, depending on the availability of aggregated building data.

  13. Rocks, Clays, Water, and Salts: Highly Durable, Infinitely Rechargeable, Eminently Controllable Thermal Batteries for Buildings

    Directory of Open Access Journals (Sweden)

    Alan W. Rempel

    2013-01-01

    Full Text Available Materials that store the energy of warm days, to return that heat during cool nights, have been fundamental to vernacular building since ancient times. Although building with thermally rechargeable materials became a niche pursuit with the advent of fossil fuel-based heating and cooling, energy and climate change concerns have sparked new enthusiasm for these substances of high heat capacity and moderate thermal conductivity: stone, adobe, rammed earth, brick, water, concrete, and more recently, phase-change materials. While broadly similar, these substances absorb and release heat in unique patterns characteristic of their mineralogies, densities, fluidities, emissivities, and latent heats of fusion. Current architectural practice, however, shows little awareness of these differences and the resulting potential to match materials to desired thermal performance. This investigation explores that potential, illustrating the correspondence between physical parameters and thermal storage-and-release patterns in direct-, indirect-, and isolated-gain passive solar configurations. Focusing on heating applications, results demonstrate the superiority of water walls for daytime warmth, the tunability of granite and concrete for evening warmth, and the exceptional ability of phase-change materials to sustain near-constant heat delivery throughout the night.

  14. Non-Linear Pushover Analysis of Flatslab Building by using Sap2000

    Directory of Open Access Journals (Sweden)

    K. Soni Priya

    2012-09-01

    Full Text Available Recent earthquakes in which many concrete structures have been severely damaged or collapsed, have indicated the need for evaluating the seismic adequacy of existing buildings. About 60% of the land area of our country is susceptible to damaging levels of seismic hazard. We can’t avoid future earthquakes, but preparedness and safe building construction practices can certainly reduce the extent of damage and loss. In order to strengthen and resist the buildings for future earthquakes, some procedures have to be adopted. One of the procedures is the static pushover analysis which is becoming a popular tool for seismic performance evaluation of existing and new structures. By conducting this push over analysis, we can know the weak zones in the structure and then we will decide whether the particular part is retrofitted or rehabilitated according to the requirement. In this paper we are performing the push over analysis on flat slabs by using most common software SAP2000.Many existing flat slab buildings may not have been designed for seismic forces. Hence it is important to study their response under seismic conditions and to evaluate seismic retrofit schemes. But when compared to beam-column connections, flat slabs are becoming popular and gaining importance as they are economica.

  15. Water conservation

    CSIR Research Space (South Africa)

    Gibberd, Jeremy T

    2009-02-01

    Full Text Available This chapter describes water systems used in green buildings and sets out some objectives that could be aimed for. It also outlines some calculations that can be used to design water systems in green buildings. Finally, aspects of green building...

  16. Radiation damage of structural materials

    International Nuclear Information System (INIS)

    Koutsky, J.; Kocik, J.

    1994-01-01

    Maintaining the integrity of nuclear power plants (NPP) is critical in the prevention or control of severe accidents. This monograph deals with both basic groups of structural materials used in the design of light-water nuclear reactors, making the primary safety barriers of NPPs. Emphasis is placed on materials used in VVER-type nuclear reactors: Cr-Mo-V and Cr-Ni-Mo-V steel for reactor pressure vessels (RPV) and Zr-Nb alloys for fuel element cladding. The book is divided into seven main chapters, with the exception of the opening one and the chapter providing phenomenological background for the subject of radiation damage. Chapters 3-6 are devoted to RPV steels and chapters 7-9 to zirconium alloys, analyzing their radiation damage structure, changes of mechanical properties due to neutron irradiation as well as factors influencing the degree of their performance degradation. The recovery of damaged materials is also discussed. Considerable attention is paid to a comparison of VVER-type and western-type light-water materials

  17. Tsunami vulnerability and damage assessment in the coastal area of Rabat and Salé, Morocco

    Directory of Open Access Journals (Sweden)

    A. Atillah

    2011-12-01

    Full Text Available This study, a companion paper to Renou et al. (2011, focuses on the application of a GIS-based method to assess building vulnerability and damage in the event of a tsunami affecting the coastal area of Rabat and Salé, Morocco. This approach, designed within the framework of the European SCHEMA project (www.schemaproject.org is based on the combination of hazard results from numerical modelling of the worst case tsunami scenario (inundation depth based on the historical Lisbon earthquake of 1755 and the Portugal earthquake of 1969, together with vulnerability building types derived from Earth Observation data, field surveys and GIS data. The risk is then evaluated for this highly concentrated population area characterized by the implementation of a vast project of residential and touristic buildings within the flat area of the Bouregreg Valley separating the cities of Rabat and Salé. A GIS tool is used to derive building damage maps by crossing layers of inundation levels and building vulnerability. The inferred damage maps serve as a base for elaborating evacuation plans with appropriate rescue and relief processes and to prepare and consider appropriate measures to prevent the induced tsunami risk.

  18. Potential Energy Flexibility for a Hot-Water Based Heating System in Smart Buildings Via Economic Model Predictive Control

    DEFF Research Database (Denmark)

    Ahmed, Awadelrahman M. A.; Zong, Yi; Mihet-Popa, Lucian

    2017-01-01

    This paper studies the potential of shifting the heating energy consumption in a residential building to low price periods based on varying electricity price signals suing Economic Model Predictive Control strategy. The investigated heating system consists of a heat pump incorporated with a hot...... water tank as active thermal energy storage, where two optimization problems are integrated together to optimize both the heat pump electricity consumption and the building heating consumption. A sensitivity analysis for the system flexibility is examined. The results revealed that the proposed...

  19. Research projects and capacity building | Breen | Water SA

    African Journals Online (AJOL)

    ... by capacity building in the context of research projects. Based on this interpretation, reasonable and unreasonable expectations with respect to the extent to which capacity building can be achieved within a given project duration are discussed. A model is suggested, which would improve understanding and delivery and ...

  20. Alternative Natural Energy Sources in Building Design.

    Science.gov (United States)

    Davis, Albert J.; Schubert, Robert P.

    This publication provides a discussion of various energy conserving building systems and design alternatives. The information presented here covers alternative space and water heating systems, and energy conserving building designs incorporating these systems and other energy conserving techniques. Besides water, wind, solar, and bio conversion…

  1. Development of the Damage Potential resulting from Avalanche Risks, Case Study Galtür (Tyrol, Austria)

    Science.gov (United States)

    Keiler, M.

    2003-04-01

    Reports on catastrophes with high damage caused by natural hazards seem to have increased in number recently. A new trend in dealing with these natural processes leads to the integration of risk into natural hazards evaluations and approaches of integral risk management. The risk resulting from natural hazards can be derived from the combination of parameters of physical processes (intensity and recurrence probability) and damage potential (probability of presence and expected damage value). Natural hazard research focuses mainly on the examination, modelling and estimation of individual geomorphological processes as well as on future developments caused by climate change. Even though damage potential has been taken into account more frequently, quantifying statements are still missing. Due to the changes of the socio-economic structures in mountain regions (urban sprawl, population growth, increased mobility and tourism) these studies are mandatory. This study presents a conceptual method that records the damage potential (probability of physical presence, evaluation of buildings) and shows the development of the damage potential resulting from avalanches since 1950. The study area is the community of Galtür, Austria. 36 percent of the existing buildings are found in officially declared avalanche hazard zones. The majority of these buildings are either agricultural or accommodation facilities. Additionally, the effects of physical planning and/or technical measures on the spatial development of the potential damage are illustrated. The results serve to improve risk determination and point out an unnoticed increase of damage potential and risk in apparently safe settlement areas.

  2. Upgrading of highly elapsed degradation damage evaluation of structural materials for the light water reactors

    International Nuclear Information System (INIS)

    Katada, Yasuyuki; Matsushima, Shinobu; Sato, Shunji

    1998-01-01

    In this study, for degradation of structural materials in accompanying with highly yearly lapse of the nuclear power plants, it was an aim to elucidate interaction between material degradation and degradation under high hot water environment. And, another aims consisted in intention of expansion protection and recovery evaluation of damage due to laser processing method and so on for welded portion showing extreme material degradation and in preparation of damage region diagram based on the obtained data. In this fiscal year, on interaction between materials and environmental degradation, it was found that as stress corrosion cracking of materials hardened by shot peening shows a resemble shapes of stress-strain curve in CERT and CLRT, shapes of load-time curve were much different. On comparison of the SP material and non-processing material, as peak current showing activity of newly created surface shows no difference, re-passivation of the SP material was found to be too late. And, on recovery evaluation of material degradation damage, as it was found that constant melt depth was essential to evaluate corrosion, a condition preparation aimed for melt depth of more than 1 mm. As only small amount of bubbles were observed at molten metal part on YAG laser processing, it was found that many small bubbles scatter at thermal effect part. (G.K.)

  3. Combining Quantitative Susceptibility Mapping with Automatic Zero Reference (QSM0) and Myelin Water Fraction Imaging to Quantify Iron-Related Myelin Damage in Chronic Active MS Lesions.

    Science.gov (United States)

    Yao, Y; Nguyen, T D; Pandya, S; Zhang, Y; Hurtado Rúa, S; Kovanlikaya, I; Kuceyeski, A; Liu, Z; Wang, Y; Gauthier, S A

    2018-02-01

    A hyperintense rim on susceptibility in chronic MS lesions is consistent with iron deposition, and the purpose of this study was to quantify iron-related myelin damage within these lesions as compared with those without rim. Forty-six patients had 2 longitudinal quantitative susceptibility mapping with automatic zero reference scans with a mean interval of 28.9 ± 11.4 months. Myelin water fraction mapping by using fast acquisition with spiral trajectory and T2 prep was obtained at the second time point to measure myelin damage. Mixed-effects models were used to assess lesion quantitative susceptibility mapping and myelin water fraction values. Quantitative susceptibility mapping scans were on average 6.8 parts per billion higher in 116 rim-positive lesions compared with 441 rim-negative lesions ( P quantitative susceptibility mapping values of both the rim and core regions ( P Quantitative susceptibility mapping scans and myelin water fraction in rim-positive lesions decreased from rim to core, which is consistent with rim iron deposition. Whole lesion myelin water fractions for rim-positive and rim-negative lesions were 0.055 ± 0.07 and 0.066 ± 0.04, respectively. In the mixed-effects model, rim-positive lesions had on average 0.01 lower myelin water fraction compared with rim-negative lesions ( P quantitative susceptibility mapping scan was negatively associated with follow-up myelin water fraction ( P Quantitative susceptibility mapping rim-positive lesions maintained a hyperintense rim, increased in susceptibility, and had more myelin damage compared with rim-negative lesions. Our results are consistent with the identification of chronic active MS lesions and may provide a target for therapeutic interventions to reduce myelin damage. © 2018 by American Journal of Neuroradiology.

  4. Seismic damage to structures in the M s6.5 Ludian earthquake

    Science.gov (United States)

    Chen, Hao; Xie, Quancai; Dai, Boyang; Zhang, Haoyu; Chen, Hongfu

    2016-03-01

    On 3 August 2014, the Ludian earthquake struck northwest Yunnan Province with a surface wave magnitude of 6.5. This moderate earthquake unexpectedly caused high fatalities and great economic loss. Four strong motion stations were located in the areas with intensity V, VI, VII and IX, near the epicentre. The characteristics of the ground motion are discussed herein, including 1) ground motion was strong at a period of less than 1.4 s, which covered the natural vibration period of a large number of structures; and 2) the release energy was concentrated geographically. Based on materials collected during emergency building inspections, the damage patterns of adobe, masonry, timber frame and reinforced concrete (RC) frame structures in areas with different intensities are summarised. Earthquake damage matrices of local buildings are also given for fragility evaluation and earthquake damage prediction. It is found that the collapse ratios of RC frame and confined masonry structures based on the new design code are significantly lower than non-seismic buildings. However, the RC frame structures still failed to achieve the `strong column, weak beam' design target. Traditional timber frame structures with a light infill wall showed good aseismic performance.

  5. Building materials. Stichwort Baustoff

    Energy Technology Data Exchange (ETDEWEB)

    Rohwer, W

    1981-01-01

    To handle building materials properly, one must know about their characteristics. This pocket book will be of help: structured like a glossary, it gives brief descriptions of the most common building materials. It is small and handy enough to be a constant companion to resident engineers, foremen, gangers, building tradesmen, and construction workers and an aid in their training. The following groups of building materials are discussed: Natural stone; units for brick walls, floors, and roofs; mortar and concrete (definitions, binders, aggregates, additives, admixtures, mixing water); special types of plaster and rendering; light-weight building boards and wood wool basis; multilayer light-weight building boards; gypsum plasterboards; chimney construction; sewers; thermal insulation and sound section; structural steels; plastics.

  6. Seismic evaluation of the LLNL plutonium facility (Building 332)

    International Nuclear Information System (INIS)

    Hall, W.J.; Sozen, M.A.

    1982-03-01

    The expected performance of the Lawrence Livermore National Laboratory (LLNL) Plutonium Facility (Building 332) subjected to earthquake ground motion has been evaluated. Anticipated behavior of the building, glove boxes, ventilation system and other systems critical for containment of plutonium is described for three severe postulated earthquake excitations. Based upon this evaluation, some damage to the building, glove boxes and ventilation system would be expected but no collapse of any structure is anticipated as a result of the postulated earthquake ground motions

  7. Analysis of Damage in Laminated Architectural Glazing Subjected to Wind Loading and Windborne Debris Impact

    Directory of Open Access Journals (Sweden)

    Daniel S. Stutts

    2013-05-01

    Full Text Available Wind loading and windborne debris (missile impact are the two primary mechanisms that result in window glazing damage during hurricanes. Wind-borne debris is categorized into two types: small hard missiles; such as roof gravel; and large soft missiles representing lumber from wood-framed buildings. Laminated architectural glazing (LAG may be used in buildings where impact resistance is needed. The glass plies in LAG undergo internal damage before total failure. The bulk of the published work on this topic either deals with the stress and dynamic analyses of undamaged LAG or the total failure of LAG. The pre-failure damage response of LAG due to the combination of wind loading and windborne debris impact is studied. A continuum damage mechanics (CDM based constitutive model is developed and implemented via an axisymmetric finite element code to study the failure and damage behavior of laminated architectural glazing subjected to combined loading of wind and windborne debris impact. The effect of geometric and material properties on the damage pattern is studied parametrically.

  8. Knowledge-Based Energy Damage Model for Evaluating Industrialised Building Systems (IBS Occupational Health and Safety (OHS Risk

    Directory of Open Access Journals (Sweden)

    Abas Nor Haslinda

    2016-01-01

    Full Text Available Malaysia’s construction industry has been long considered hazardous, owing to its poor health and safety record. It is proposed that one of the ways to improve safety and health in the construction industry is through the implementation of ‘off-site’ systems, commonly termed ‘industrialised building systems (IBS’ in Malaysia. This is deemed safer based on the risk concept of reduced exposure, brought about by the reduction in onsite workers; however, no method yet exists for determining the relative safety of various construction methods, including IBS. This study presents a comparative evaluation of the occupational health and safety (OHS risk presented by different construction approaches, namely IBS and traditional methods. The evaluation involved developing a model based on the concept of ‘argumentation theory’, which helps construction designers integrate the management of OHS risk into the design process. In addition, an ‘energy damage model’ was used as an underpinning framework. Development of the model was achieved through three phases, namely Phase I – knowledge acquisitaion, Phase II – argument trees mapping, and Phase III – validation of the model. The research revealed that different approaches/methods of construction projects carried a different level of energy damage, depending on how the activities were carried out. A study of the way in which the risks change from one construction process to another shows that there is a difference in the profile of OHS risk between IBS construction and traditional methods.Therefore, whether the option is an IBS or traditional approach, the fundamental idea of the model is to motivate construction designers or decision-makers to address safety in the design process and encourage them to examine carefully the probable OHS risk variables surrounding an action, thus preventing accidents in construction.

  9. Lightning protection system analysis at Multipurpose Reactor G A. Siwabessy building

    International Nuclear Information System (INIS)

    Teguh-Sulistyo

    2003-01-01

    Analysis to the part of lightning protection system at Multi Purpose Reactor GA Siwabessy (RSG-GAS) have been done. Observation examined the damage of some part of the earthing system caused by human error of chemically system. The analysis performed some assumptions and simulations to the points of lightning stroke. From this analysis obtained that the reactor building do not have vertical finial which can protect effectively to the whole reactor building and auxiliary building. Installing some new finials at some places are needed to protect building therefore the reactor building and auxiliary building well safe from lighting stroke

  10. Damage Analysis and Evaluation of Light Steel Structures Exposed to Wind Hazards

    OpenAIRE

    Na Yang; Fan Bai

    2017-01-01

    Compared to hot-rolled steel structures, cold-formed steel structures are susceptible to extreme winds because of the light weight of the building and its components. Many modern cold-formed steel structures have sustained significant structural damage ranging from loss of cladding to complete collapse in recent cyclones. This article first provides some real damage cases for light steel structures induced by the high winds. After that, the paper reviews research on the damage analysis and e...

  11. Postbuckling Investigations of Piezoelectric Microdevices Considering Damage Effects

    Science.gov (United States)

    Sun, Zhigang; Wang, Xianqiao

    2014-01-01

    Piezoelectric material has been emerging as a popular building block in MEMS devices owing to its unique mechanical and electrical material properties. However, the reliability of MEMS devices under buckling deformation environments remains elusive and needs to be further explored. Based on the Talreja's tensor valued internal state damage variables as well as the Helmhotlz free energy of piezoelectric material, a constitutive model of piezoelectric materials with damage is presented. The Kachanvo damage evolution law under in-plane compressive loads is employed. The model is applied to the specific case of the postbuckling analysis of the piezoelectric plate with damage. Then, adopting von Karman's plate theory, the nonlinear governing equations of the piezoelectric plates with initial geometric deflection including damage effects under in-plane compressive loads are established. By using the finite difference method and the Newmark scheme, the damage evolution for damage accumulation is developed and the finite difference procedure for postbuckling equilibrium path is simultaneously employed. Numerical results show the postbuckling behaviors of initial flat and deflected piezoelectric plates with damage or no damage under different sets of electrical loading conditions. The effects of applied voltage, aspect ratio of plate, thick-span ratio of plate, damage as well as initial geometric deflections on the postbuckling behaviors of the piezoelectric plate are discussed. PMID:24618774

  12. POST-DISASTER DAMAGE ASSESSMENT THROUGH COHERENT CHANGE DETECTION ON SAR IMAGERY

    Directory of Open Access Journals (Sweden)

    L. Guida

    2018-04-01

    Full Text Available Damage assessment is a fundamental step to support emergency response and recovery activities in a post-earthquake scenario. In recent years, UAVs and satellite optical imagery was applied to assess major structural damages before technicians could reach the areas affected by the earthquake. However, bad weather conditions may harm the quality of these optical assessments, thus limiting the practical applicability of these techniques. In this paper, the application of Synthetic Aperture Radar (SAR imagery is investigated and a novel approach to SAR-based damage assessment is presented. Coherent Change Detection (CCD algorithms on multiple interferometrically pre-processed SAR images of the area affected by the seismic event are exploited to automatically detect potential damages to buildings and other physical structures. As a case study, the 2016 Central Italy earthquake involving the cities of Amatrice and Accumoli was selected. The main contribution of the research outlined above is the integration of a complex process, requiring the coordination of a variety of methods and tools, into a unitary framework, which allows end-to-end application of the approach from SAR data pre-processing to result visualization in a Geographic Information System (GIS. A prototype of this pipeline was implemented, and the outcomes of this methodology were validated through an extended comparison with traditional damage assessment maps, created through photo-interpretation of high resolution aerial imagery. The results indicate that the proposed methodology is able to perform damage detection with a good level of accuracy, as most of the detected points of change are concentrated around highly damaged buildings.

  13. Post-Disaster Damage Assessment Through Coherent Change Detection on SAR Imagery

    Science.gov (United States)

    Guida, L.; Boccardo, P.; Donevski, I.; Lo Schiavo, L.; Molinari, M. E.; Monti-Guarnieri, A.; Oxoli, D.; Brovelli, M. A.

    2018-04-01

    Damage assessment is a fundamental step to support emergency response and recovery activities in a post-earthquake scenario. In recent years, UAVs and satellite optical imagery was applied to assess major structural damages before technicians could reach the areas affected by the earthquake. However, bad weather conditions may harm the quality of these optical assessments, thus limiting the practical applicability of these techniques. In this paper, the application of Synthetic Aperture Radar (SAR) imagery is investigated and a novel approach to SAR-based damage assessment is presented. Coherent Change Detection (CCD) algorithms on multiple interferometrically pre-processed SAR images of the area affected by the seismic event are exploited to automatically detect potential damages to buildings and other physical structures. As a case study, the 2016 Central Italy earthquake involving the cities of Amatrice and Accumoli was selected. The main contribution of the research outlined above is the integration of a complex process, requiring the coordination of a variety of methods and tools, into a unitary framework, which allows end-to-end application of the approach from SAR data pre-processing to result visualization in a Geographic Information System (GIS). A prototype of this pipeline was implemented, and the outcomes of this methodology were validated through an extended comparison with traditional damage assessment maps, created through photo-interpretation of high resolution aerial imagery. The results indicate that the proposed methodology is able to perform damage detection with a good level of accuracy, as most of the detected points of change are concentrated around highly damaged buildings.

  14. Laser Induced Damage of Potassium Dihydrogen Phosphate (KDP Optical Crystal Machined by Water Dissolution Ultra-Precision Polishing Method

    Directory of Open Access Journals (Sweden)

    Yuchuan Chen

    2018-03-01

    Full Text Available Laser induced damage threshold (LIDT is an important optical indicator for nonlinear Potassium Dihydrogen Phosphate (KDP crystal used in high power laser systems. In this study, KDP optical crystals are initially machined with single point diamond turning (SPDT, followed by water dissolution ultra-precision polishing (WDUP and then tested with 355 nm nanosecond pulsed-lasers. Power spectral density (PSD analysis shows that WDUP process eliminates the laser-detrimental spatial frequencies band of micro-waviness on SPDT machined surface and consequently decreases its modulation effect on the laser beams. The laser test results show that LIDT of WDUP machined crystal improves and its stability has a significant increase by 72.1% compared with that of SPDT. Moreover, a subsequent ultrasonic assisted solvent cleaning process is suggested to have a positive effect on the laser performance of machined KDP crystal. Damage crater investigation indicates that the damage morphologies exhibit highly thermal explosion features of melted cores and brittle fractures of periphery material, which can be described with the classic thermal explosion model. The comparison result demonstrates that damage mechanisms for SPDT and WDUP machined crystal are the same and WDUP process reveals the real bulk laser resistance of KDP optical crystal by removing the micro-waviness and subsurface damage on SPDT machined surface. This improvement of WDUP method makes the LIDT more accurate and will be beneficial to the laser performance of KDP crystal.

  15. Heat and mass transfer in building services design

    CERN Document Server

    Moss, Keith

    1998-01-01

    Building design is increasingly geared towards low energy consumption. Understanding the fundamentals of heat transfer and the behaviour of air and water movements is more important than ever before. Heat and Mass Transfer in Building Services Design provides an essential underpinning knowledge for the technology subjects of space heating, water services, ventilation and air conditioning. This new text: *provides core understanding of heat transfer and fluid flow from a building services perspective *complements a range of courses in building services engineering *

  16. Efforts to control radiation build-up in Ringhals

    Energy Technology Data Exchange (ETDEWEB)

    Egner, K.; Aronsson, P.O.; Erixon, O. [Vattenfall AB, Vaeroebacka (Sweden)

    1995-03-01

    It is well known that good control of the primary chemistry in a PWR is essential in order to minimize material problems and fuel damages. It has also been well established that the water chemistry has a great influence on accumulation of corrosion products on the fuel and the radiation build-up on primary system surfaces. Ringhals was one of the pioneers to increase operating pH in order to reduce radiation build-up and has now been operating for ten years with pH at 7.4 or (in later years) 7.2. Our experience is favourable and includes low radiation levels in the new (1989) steam generators of Ringhals 2. Ringhals 4 has operated almost its whole life at pH 7.2 or higher and it remains one of the cleanest PWRs of its vintage. In addition to strict adherence to a stable operating chemistry, Ringhals is now working on a program with the aim to find optimum shut-down and start-up chemistry to reduce activity levels in the primary systems. A particular goal is to use the shut-down and start-up chemistry at the 1994 outage in Ringhals 3 in order to reduce doserates in preparation for the planned steam generator replacement in 1995. The paper summarizes the experience to date of the established operating chemistry, on-going tests with modified shut-down and start-up chemistry and other measures to limit or reduce the activity build-up.

  17. Efforts to control radiation build-up in Ringhals

    International Nuclear Information System (INIS)

    Egner, K.; Aronsson, P.O.; Erixon, O.

    1995-01-01

    It is well known that good control of the primary chemistry in a PWR is essential in order to minimize material problems and fuel damages. It has also been well established that the water chemistry has a great influence on accumulation of corrosion products on the fuel and the radiation build-up on primary system surfaces. Ringhals was one of the pioneers to increase operating pH in order to reduce radiation build-up and has now been operating for ten years with pH at 7.4 or (in later years) 7.2. Our experience is favourable and includes low radiation levels in the new (1989) steam generators of Ringhals 2. Ringhals 4 has operated almost its whole life at pH 7.2 or higher and it remains one of the cleanest PWRs of its vintage. In addition to strict adherence to a stable operating chemistry, Ringhals is now working on a program with the aim to find optimum shut-down and start-up chemistry to reduce activity levels in the primary systems. A particular goal is to use the shut-down and start-up chemistry at the 1994 outage in Ringhals 3 in order to reduce doserates in preparation for the planned steam generator replacement in 1995. The paper summarizes the experience to date of the established operating chemistry, on-going tests with modified shut-down and start-up chemistry and other measures to limit or reduce the activity build-up

  18. Structural rehabilitation of old buildings

    CERN Document Server

    Guedes, João; Varum, Humberto

    2014-01-01

    The present book describes the different construction systems and structural materials and solutions within the main old buildings typologies, and it analyses the particularities of each of them, including mechanical properties, structural behaviour, typical damage patterns and collapse mechanisms. Common or pioneering intervention measures to repair and/or strengthen some of these structural elements are also reviewed.

  19. Photo-catalytic reactors for in-building grey water reuse. Comparison with biological processes and market potential

    Energy Technology Data Exchange (ETDEWEB)

    Jefferson, B.; Murray, C.; Diaper, C.; Parsons, S.A.; Jeffrey, P. [School of Water Sciences, Cranfield Univ., Cranfield, Bedfordshire (United Kingdom); Bedel, C. [Dept. of Industrial Process, National Inst. of Applied Sciences (France); Centeno, C. [Dept. of the Faculty of Engineering, Univ. of Santo Tomas, Manila (Philippines)

    2003-07-01

    Photo catalytic reactors potentially have a market in the reuse of grey water as they do not suffer from problems associated with toxic shocks and can be compact. The process is dependant upon the ratio of TOC to TiO{sub 2} concentration such that a greater proportion of the feed is degraded when either are increased. Economic assessment of grey water recycling showed both scale of operation and regional location to be the two most important factors in deciding the financial acceptability of any reuse technology. Overall the assessment suggested that photo catalytic oxidation (PCO) technology was suitable for grey water recycling and that the technology should be marketed at large buildings such as residential accommodation and offices. (orig.)

  20. Solar heating and hot water system installed at Municipal Building complex, Abbeville, South Carolina

    Science.gov (United States)

    1979-01-01

    Information on the solar energy system installed at the new municipal building for the City of Abbeville, SC is presented, including a description of solar energy system and buildings, lessons learned, and recommendations. The solar space heating system is a direct air heating system. The flat roof collector panel was sized to provide 75% of the heating requirement based on an average day in January. The collectors used are job-built with two layers of filon corrugated fiberglass FRP panels cross lapped make up the cover. The storage consists of a pit filled with washed 3/4 in - 1 1/2 in diameter crushed granite stone. The air handler includes the air handling mechanism, motorized dampers, air circulating blower, sensors, control relays and mode control unit. Solar heating of water is provided only those times when the hot air in the collector is exhausted to the outside.

  1. National Ignition Facility subsystem design requirements optics assembly building (OAB) SSDR 1.2.2.3

    International Nuclear Information System (INIS)

    Kempel, P.; Hands, J.

    1996-01-01

    This Subsystem Design Requirement (SSDR) document establishes the performance, design, and verification requirements 'for the conventional building systems and subsystems of the Optics Assembly Building (OAB). These building system requirements are associated with housing and supporting the operational flow of personnel and materials throughout the OAB for preparing and repairing optical and mechanical components used in the National Ignition Facility (NIF) Laser and Target Building (LTAB). This SSDR addresses the following subsystems associated with the OAB: * Structural systems for the building spaces and operational-support equipment and building- support equipment. * Architectural building features associated with housing the space, operational cleanliness, and functional operation of the facility. * Heating, Ventilating, and Air Conditioning (HVAC) systems for maintaining a clean and thermally stable ambient environment within the facility. * Plumbing systems that provide potable water and sanitary facilities for the occupants and stormwater drainage for transporting rainwater. * Fire Protection systems that guard against fire damage to the facility and its contents. * Material handling equipment for transferring optical assemblies and other materials within building areas and to the LTAB. * Mechanical process piping systems for liquids and gases that provide cooling, cleaning, and other service to optical and mechanical components. * Electrical power and grounding systems that provide service to the building and equipment, including lighting distribution and communications systems for the facilities. * Instrumentation and control systems that ensure the safe operation of conventional facilities systems, such as those listed above. Generic design criteria, such as siting data, seismic requirements, utility availability, and other information that contributes to the OAB design, are not addressed in this document

  2. A Multi-Tiered Approach for Building Capacity in Hydrologic Modeling for Water Resource Management in Developing Regions

    Science.gov (United States)

    Markert, K. N.; Limaye, A. S.; Rushi, B. R.; Adams, E. C.; Anderson, E.; Ellenburg, W. L.; Mithieu, F.; Griffin, R.

    2017-12-01

    Water resource management is the process by which governments, businesses and/or individuals reach and implement decisions that are intended to address the future quantity and/or quality of water for societal benefit. The implementation of water resource management typically requires the understanding of the quantity and/or timing of a variety of hydrologic variables (e.g. discharge, soil moisture and evapotranspiration). Often times these variables for management are simulated using hydrologic models particularly in data sparse regions. However, there are several large barriers to entry in learning how to use models, applying best practices during the modeling process, and selecting and understanding the most appropriate model for diverse applications. This presentation focuses on a multi-tiered approach to bring the state-of-the-art hydrologic modeling capabilities and methods to developing regions through the SERVIR program, a joint NASA and USAID initiative that builds capacity of regional partners and their end users on the use of Earth observations for environmental decision making. The first tier is a series of trainings on the use of multiple hydrologic models, including the Variable Infiltration Capacity (VIC) and Ensemble Framework For Flash Flood Forecasting (EF5), which focus on model concepts and steps to successfully implement the models. We present a case study for this in a pilot area, the Nyando Basin in Kenya. The second tier is focused on building a community of practice on applied hydrology modeling aimed at creating a support network for hydrologists in SERVIR regions and promoting best practices. The third tier is a hydrologic inter-comparison project under development in the SERVIR regions. The objective of this step is to understand model performance under specific decision-making scenarios, and to share knowledge among hydrologists in SERVIR regions. The results of these efforts include computer programs, training materials, and new

  3. Ultrasound-induced cavitation damage to external epithelia of fish skin.

    Science.gov (United States)

    Frenkel, V; Kimmel, E; Iger, Y

    1999-10-01

    Transmission electron microscopy was used to show the effects of therapeutic ultrasound (fish skin. Exposures of up to 90 s produced damage to 5 to 6 of the outermost layers. Negligible temperature elevations and lack of damage observed when using degassed water indicated that the effects were due to cavitation. The minimal intensity was determined for inducing cellular damage, where the extent and depth of damage to the tissues was correlated to the exposure duration. The results may be interpreted as a damage front, advancing slowly from the outer cells inward, presumably in association with the slow replacement of the perforated cell contents with the surrounding water. This study illustrates that a controlled level of microdamage may be induced to the outer layers of the tissues.

  4. Application of laser scanning technique in earthquake protection of Istanbul's historical heritage buildings

    Science.gov (United States)

    Çaktı, Eser; Ercan, Tülay; Dar, Emrullah

    2017-04-01

    Istanbul's vast historical and cultural heritage is under constant threat of earthquakes. Historical records report repeated damages to the city's landmark buildings. Our efforts towards earthquake protection of several buildings in Istanbul involve earthquake monitoring via structural health monitoring systems, linear and non-linear structural modelling and analysis in search of past and future earthquake performance, shake-table testing of scaled models and non-destructive testing. More recently we have been using laser technology in monitoring structural deformations and damage in five monumental buildings which are Hagia Sophia Museum and Fatih, Sultanahmet, Süleymaniye and Mihrimah Sultan Mosques. This presentation is about these efforts with special emphasis on the use of laser scanning in monitoring of edifices.

  5. Rational Consumption of Water in Administrative Public Buildings: The Experience of the Bahia Administrative Center, Brazil

    Directory of Open Access Journals (Sweden)

    Samara Fernanda da Silva

    2014-08-01

    Full Text Available The government has to lead, by example, the effort for more rational water use. Nevertheless, public buildings in countries like Brazil lack the operational and maintenance organization necessary to induce better environmental practices. This paper presents the results of a five-year effort to control and reduce water use in governmental facilities in Salvador, Bahia. Seventeen state government headquarters in Bahia took part in this initiative. The basic actions taken include: daily monitoring and analysis of water consumption, inspections and adjustments of hydraulic equipment flow, rapid repair of leaks and layout improvements in toilets. All of these are part of the main initiative, which aims to implement water management in the facilities. Ecoteams were created and trained to conduct these efforts. Water control, consumption analysis and communication have been made using AGUAPURA VIANET, an Internet software designed by the Federal University of Bahia for this specific purpose. From June 2008, to December 2013, an estimated 270,000 m3 of potable water have been saved, which represents US$ 2.7 million in water and waste water costs. This represents a monthly savings of 31% in expenses compared to the practices before the program started.

  6. [A Method Research on Environmental Damage Assessment of a Truck Rollover Pollution Incident].

    Science.gov (United States)

    Cai, Feng; Zhao, Shi-ho; Chen, Gang-cai; Xian, Si-shu; Yang, Qing-ling; Zhou, Xian-jie; Yu, Hai

    2015-05-01

    With high occurrence of sudden water pollution incident, China faces an increasingly severe situation of water environment. In order to deter the acts of environmental pollution, ensure the damaged resources of environment can be restored and compensated, it is very critical to quantify the economic losses caused by the sudden water pollution incident. This paper took truck rollover pollution incidents in Chongqing for an example, established a set of evaluation method for quantifying the environmental damage, and then assessed the environmental damage by the method from four aspects, including the property damage, ecological environment and resources damages, the costs of administrative affairs in emergency disposal, and the costs of investigation and evaluation.

  7. Modeling of two-storey precast school building using Ruaumoko 2D program

    Science.gov (United States)

    Hamid, N. H.; Tarmizi, L. H.; Ghani, K. D.

    2015-05-01

    The long-distant earthquake loading from Sumatra and Java Island had caused some slight damages to precast and reinforced concrete buildings in West Malaysia such as cracks on wall panels, columns and beams. Subsequently, the safety of existing precast concrete building is needed to be analyzed because these buildings were designed using BS 8110 which did not include the seismic loading in the design. Thus, this paper emphasizes on the seismic performance and dynamic behavior of precast school building constructed in Malaysia under three selected past earthquakes excitations ; El Centro 1940 North-South, El Centro East-West components and San Fernando 1971 using RUAUMOKO 2D program. This program is fully utilized by using prototype precast school model and dynamic non-linear time history analysis. From the results, it can be concluded that two-storey precast school building has experienced severe damage and partial collapse especially at beam-column joint under San Fernando and El Centro North-South Earthquake as its exceeds the allowable inter-storey drift and displacement as specified in Eurocode 8. The San Fernando earthquake has produced a massive destruction to the precast building under viscous damping, ξ = 5% and this building has generated maximum building displacement of 435mm, maximum building drift of 0.68% and maximum bending moment at 8458kNm.

  8. Modeling of two-storey precast school building using Ruaumoko 2D program

    International Nuclear Information System (INIS)

    Hamid, N. H.; Tarmizi, L. H.; Ghani, K. D.

    2015-01-01

    The long-distant earthquake loading from Sumatra and Java Island had caused some slight damages to precast and reinforced concrete buildings in West Malaysia such as cracks on wall panels, columns and beams. Subsequently, the safety of existing precast concrete building is needed to be analyzed because these buildings were designed using BS 8110 which did not include the seismic loading in the design. Thus, this paper emphasizes on the seismic performance and dynamic behavior of precast school building constructed in Malaysia under three selected past earthquakes excitations ; El Centro 1940 North-South, El Centro East-West components and San Fernando 1971 using RUAUMOKO 2D program. This program is fully utilized by using prototype precast school model and dynamic non-linear time history analysis. From the results, it can be concluded that two-storey precast school building has experienced severe damage and partial collapse especially at beam-column joint under San Fernando and El Centro North-South Earthquake as its exceeds the allowable inter-storey drift and displacement as specified in Eurocode 8. The San Fernando earthquake has produced a massive destruction to the precast building under viscous damping, ξ = 5% and this building has generated maximum building displacement of 435mm, maximum building drift of 0.68% and maximum bending moment at 8458kNm

  9. Modeling of two-storey precast school building using Ruaumoko 2D program

    Energy Technology Data Exchange (ETDEWEB)

    Hamid, N. H.; Tarmizi, L. H.; Ghani, K. D. [Faculty of Civil Engineering, Universiti Teknologi MARA, 40450 Shah Alam, Selangor (Malaysia)

    2015-05-15

    The long-distant earthquake loading from Sumatra and Java Island had caused some slight damages to precast and reinforced concrete buildings in West Malaysia such as cracks on wall panels, columns and beams. Subsequently, the safety of existing precast concrete building is needed to be analyzed because these buildings were designed using BS 8110 which did not include the seismic loading in the design. Thus, this paper emphasizes on the seismic performance and dynamic behavior of precast school building constructed in Malaysia under three selected past earthquakes excitations ; El Centro 1940 North-South, El Centro East-West components and San Fernando 1971 using RUAUMOKO 2D program. This program is fully utilized by using prototype precast school model and dynamic non-linear time history analysis. From the results, it can be concluded that two-storey precast school building has experienced severe damage and partial collapse especially at beam-column joint under San Fernando and El Centro North-South Earthquake as its exceeds the allowable inter-storey drift and displacement as specified in Eurocode 8. The San Fernando earthquake has produced a massive destruction to the precast building under viscous damping, ξ = 5% and this building has generated maximum building displacement of 435mm, maximum building drift of 0.68% and maximum bending moment at 8458kNm.

  10. Emergency building temperature restrictions. Final evaluation

    Energy Technology Data Exchange (ETDEWEB)

    None

    1980-11-01

    On July 5, 1979, DOE promulgated final regulations of the Emergency Building Temperature Restrictions program, placing emergency restrictions on thermostat settings for space heating, space cooling, and hot water in commercial, industrial, and nonresidential public buildings. The final regulations restricted space heating to a maximum of 65/sup 0/F, hot water temperature to a maximum of 105/sup 0/F, and cooling temperature to a minimum of 78/sup 0/F. A comprehensive evaluation of the entire EBTF program for a nine-month period from July 16, 1979 is presented. In Chapter 1, an estimate of the population of buildings covered by EBTR is presented. In Chapter 2, EBTR compliance by building type and region is reported. Exemptions are also discussed. In Chapter 3, the simulations of building energy use are explained and the relative impact of various building characteristics and effectiveness of different control strategies are estimated. Finally, in Chapter 4, the methodology for scaling the individual building energy savings to the national level is described, and estimated national energy savings are presented.

  11. Actual building energy use patterns and their implications for predictive modeling

    International Nuclear Information System (INIS)

    Heidarinejad, Mohammad; Cedeño-Laurent, Jose G.; Wentz, Joshua R.; Rekstad, Nicholas M.; Spengler, John D.; Srebric, Jelena

    2017-01-01

    Highlights: • Developed three building categories based on energy use patterns of campus buildings. • Evaluated implication of temporal energy data granularity on predictive modeling. • Demonstrated importance of monitoring daily chilled water consumption. • Identified interval electricity data as an indicator of building operation schedules. • Demonstrated a calibration process for energy modeling of a campus building. - Abstract: The main goal of this study is to understand the patterns in which commercial buildings consume energy, rather than evaluating building energy use based on aggregate utility bills typically linked to building principal tenant activity or occupancy type. The energy consumption patterns define buildings as externally-load, internally-load, or mixed-load dominated buildings. Penn State and Harvard campuses serve as case studies for this particular research project. The buildings in these two campuses use steam, chilled water, and electricity as energy commodities and maintain databases of different resolutions to include minute, hourly, daily, and monthly data instances depending on the commodity and available data acquisition system. The results of this study show monthly steam consumption directly correlates to outdoor environmental conditions for 88% of the studied buildings, while chilled water consumption has negligible correlation to the outdoor environmental conditions. Thus, in terms of monthly chilled water consumption, 86% of buildings are internally-load and mixed-load dominated, respectively. Chilled water consumption is better suited for the daily analyses compared to the monthly and hourly analyses. While the influence of building operation schedules affects the analyses at the hourly level, the monthly chilled water consumptions are not good indicators of the building energy consumption patterns. Electricity consumption at the monthly (or seasonal) level can support the building energy simulation tools for the

  12. Feral burro populations: Distribution and damage assessment

    Energy Technology Data Exchange (ETDEWEB)

    Tiller, B.L.

    1997-12-01

    This report was prepared to document (1) regional use of the National Training Center (NTC), Fort Irwin, CA, by burros, (2)influence of available water sources for burro use, (3) burro-related damage at several NTC sensitive habitat areas, and (4) management recommendations. All work described in this report was conducted in 1996 and 1997. Roadside transects were conducted and mapped using Geographical Positioning Systems/Geographical Information Systems (GPS/GIS) to indirectly measure relative abundance of feral burros (scat per mile) and to examine the spatial relationship of burro use to permanent or semi-permanent water sources that exist on the NTC. The authors also surveyed several permanent springs for burro-related damage and mapped the impact areas using GPS/GIS to quantify the extent of damage and to provide guidance on size and extent of burro exclosures in those areas. Photographs of the spring sites were also archived and permanent photo points were established for long-term monitoring of feral burro damage areas. In addition, aquatic invertebrate data collected during another spring site study were summarized and discussed in relation to burro-related impacts on the NTC`s sensitive habitats. Several water-quality parameters were also obtained from each spring, including temperature, dissolved oxygen, pH, and total dissolved solids.

  13. Water pollution causes ultrastructural and functional damages in Pellia neesiana (Gottsche) Limpr.

    Science.gov (United States)

    Basile, Adriana; Sorbo, Sergio; Lentini, Marco; Conte, Barbara; Esposito, Sergio

    2017-09-01

    The aim of this work is to evaluate the effects of freshwater pollution in the heavily contaminated Sarno River (Campania, South Italy), using Pellia neesiana (Pelliaceae Metzgeriales) in order to propose this liverwort as a potential bioindicator, able to record the effects of water pollution, particularly the one related to metal (loid) contamination. Samples of P. neesiana in nylon bags were disposed floating for one week on the waters of Sarno River in three sites characterised by an increasing pollution. As control, some specimens were cultured in vitro in Cd- and Pb-added media, at the same pollutants' levels as measured in the most polluted site. P. neesiana cell ultrastructure was modified and severe alterations were observed in chloroplasts from samples exposed in the most polluted site, and Cd- and Pb-cultured samples. Concurrently, a strong increase in the occurrence of Heat shock proteins 70 (HSP70) was detected in gametophytes following the pollution gradient. In conclusion, ultrastructural damages can be directly related to HSP 70 occurrence in liverwort tissues, and proportional to the degree of pollution present in the river; thus our study suggests P. neesiana as an affordable bioindicator of freshwaters pollution. Copyright © 2016 Elsevier GmbH. All rights reserved.

  14. OpenBAN: An Open Building ANalytics Middleware for Smart Buildings

    Directory of Open Access Journals (Sweden)

    Pandarasamy Arjunan

    2016-03-01

    Full Text Available Towards the realization of smart building applications, buildings are increasingly instrumented with diverse sensors and actuators. These sensors generate large volumes of data which can be analyzed for optimizing building operations. Many building energy management tasks such as energy forecasting, disaggregation, among others require complex analytics leveraging collected sensor data. While several standalone and cloud-based systems for archiving, sharing and visualizing sensor data have emerged, their support for analyzing sensor data streams is primitive and limited to rule-based actions based on thresholds and simple aggregation functions. We develop OpenBAN, an open source sensor data analytics middleware for buildings, to make analytics an integral component of modern smart building applications. OpenBAN provides a framework of extensible sensor data processing elements for identifying various building context, which different applications can leverage. We validate the capabilities of OpenBAN by developing three representative real-world applications which are deployed in our test-bed buildings: (i household energy disaggregation, (ii detection of sprinkler usage from water meter data, and (iii electricity demand forecasting. We also provide a preliminary system performance of OpenBAN when deployed in the cloud and locally.

  15. Capturing changes in flood risk with Bayesian approaches for flood damage assessment

    Science.gov (United States)

    Vogel, Kristin; Schröter, Kai; Kreibich, Heidi; Thieken, Annegret; Müller, Meike; Sieg, Tobias; Laudan, Jonas; Kienzler, Sarah; Weise, Laura; Merz, Bruno; Scherbaum, Frank

    2016-04-01

    Flood risk is a function of hazard as well as of exposure and vulnerability. All three components are under change over space and time and have to be considered for reliable damage estimations and risk analyses, since this is the basis for an efficient, adaptable risk management. Hitherto, models for estimating flood damage are comparatively simple and cannot sufficiently account for changing conditions. The Bayesian network approach allows for a multivariate modeling of complex systems without relying on expert knowledge about physical constraints. In a Bayesian network each model component is considered to be a random variable. The way of interactions between those variables can be learned from observations or be defined by expert knowledge. Even a combination of both is possible. Moreover, the probabilistic framework captures uncertainties related to the prediction and provides a probability distribution for the damage instead of a point estimate. The graphical representation of Bayesian networks helps to study the change of probabilities for changing circumstances and may thus simplify the communication between scientists and public authorities. In the framework of the DFG-Research Training Group "NatRiskChange" we aim to develop Bayesian networks for flood damage and vulnerability assessments of residential buildings and companies under changing conditions. A Bayesian network learned from data, collected over the last 15 years in flooded regions in the Elbe and Danube catchments (Germany), reveals the impact of many variables like building characteristics, precaution and warning situation on flood damage to residential buildings. While the handling of incomplete and hybrid (discrete mixed with continuous) data are the most challenging issues in the study on residential buildings, a similar study, that focuses on the vulnerability of small to medium sized companies, bears new challenges. Relying on a much smaller data set for the determination of the model

  16. A method for the estimation of the probability of damage due to earthquakes

    International Nuclear Information System (INIS)

    Alderson, M.A.H.G.

    1979-07-01

    The available information on seismicity within the United Kingdom has been combined with building damage data from the United States to produce a method of estimating the probability of damage to structures due to the occurrence of earthquakes. The analysis has been based on the use of site intensity as the major damage producing parameter. Data for structural, pipework and equipment items have been assumed and the overall probability of damage calculated as a function of the design level. Due account is taken of the uncertainties of the seismic data. (author)

  17. Solar hot water systems application to the solar building test facility and the Tech House

    Science.gov (United States)

    Goble, R. L.; Jensen, R. N.; Basford, R. C.

    1976-01-01

    Projects which relate to the current national thrust toward demonstrating applied solar energy are discussed. The first project has as its primary objective the application of a system comprised of a flat plate collector field, an absorption air conditioning system, and a hot water heating system to satisfy most of the annual cooling and heating requirements of a large commercial office building. The other project addresses the application of solar collector technology to the heating and hot water requirements of a domestic residence. In this case, however, the solar system represents only one of several important technology items, the primary objective for the project being the application of space technology to the American home.

  18. Comparison of main-shock and aftershock fragility curves developed for New Zealand and US buildings

    Science.gov (United States)

    Uma, S.R.; Ryu, H.; Luco, N.; Liel, A.B.; Raghunandan, M.

    2011-01-01

    Seismic risk assessment involves the development of fragility functions to express the relationship between ground motion intensity and damage potential. In evaluating the risk associated with the building inventory in a region, it is essential to capture 'actual' characteristics of the buildings and group them so that 'generic building types' can be generated for further analysis of their damage potential. Variations in building characteristics across regions/countries largely influence the resulting fragility functions, such that building models are unsuitable to be adopted for risk assessment in any other region where a different set of building is present. In this paper, for a given building type (represented in terms of height and structural system), typical New Zealand and US building models are considered to illustrate the differences in structural model parameters and their effects on resulting fragility functions for a set of main-shocks and aftershocks. From this study, the general conclusion is that the methodology and assumptions used to derive basic capacity curve parameters have a considerable influence on fragility curves.

  19. Damage Detection of Reinforced Concrete Shear Walls Using Mathematical Transformations

    Directory of Open Access Journals (Sweden)

    Hosein Naderpour

    2017-02-01

    Full Text Available Structural health monitoring is a procedure to provide accurate and immediate information on the condition and efficiency of structures. There is variety of damage factors and the unpredictability of future damage, is a necessity for the use of structural health monitoring. Structural health monitoring and damage detection in early stages is one of the most interesting topics that had been paid attention because the majority of damages can be repaired and reformed by initial evaluation ,thus the spread of damage to the structures, building collapse and rising of costs can be avoided .Detection of concrete shear wall damages are designed to withstand the lateral load on the structure is critical .Because failures and  malfunctions of shear walls can lead to serious damage or even progressive dilapidation of concrete structures .Change in stiffness and frequency can clearly show the damage occurrence. Mathematical transformation is also a tool to detect damage. In this article, with non- linear time history analysis, the finite element model of structures with concrete shear walls subject to four earthquakes have extracted and using Fourier and wavelet transform, the presence of shear walls is detected at the time of damage.

  20. Green commercial building insurance in Malaysia

    Science.gov (United States)

    Yang, Yu Xin Ou; Chew, Boon Cheong; Loo, Heoy Shin; Tan, Lay Hong

    2017-03-01

    Green building construction is growing tremendously globally even in Malaysia. Currently, there are approximate 636 buildings have registered and to be certified with Green Building Index. Among these buildings, 45 buildings have already fulfilled the requirements and fully certified. The other buildings still under provisional certification stage. Malaysia had adopted Green Building Index in 2009 to support a move to promote green building concept. Malaysia starts to move towards green building because Malaysian construction and building industry realizes that both energy consumed and waste produced are reduced without irreversible impacts to ecosystems. Consequently, insurance companies such as Fireman's Fund from America has started the green building insurance policies for their green building in the year of 2006, while Malaysia still remain the coverage for green buildings using conventional property insurance. There are lacks of efforts to be seen from insurance companies to propose green building insurance for these green buildings. There are a few factors which can take into consideration for insurance companies to start the very first green building insurance in Malaysia. Although there are challenges, some efficient strategies have been identified to overcome the problems. The methods used in this research topic is qualitative research. The results obtained shows that green commercial building insurance has a huge business opportunity in Malaysia because the number of green commercial buildings are increasing tremendously in Malaysia. It is a favor to implement green building insurance in Malaysia. Furthermore, insurance companies can consider to add in extra coverage in standard building policy to provide extra protection for non-certified green buildings which have the intention to rebuilt in green when damage happens. Generally, it is very important to introduce green commercial buildings insurance into Malaysia so that all of the green commercial

  1. Building Damage and Business Continuity Management in the Event of Natural Hazards: Case Study of the 2004 Tsunami in Sri Lanka

    Directory of Open Access Journals (Sweden)

    Masami Sugiura

    2013-01-01

    Full Text Available The Sumatra Earthquake and Indian Ocean Tsunami event on the 26 December 2004 has provided a unique and valuable opportunity to evaluate the performance of various structures, facilities and lifeline systems during the tsunami wave attacks. There are especially meaningful observations concerning the structural changes due to the tsunami forces, which open up a wide area of research to develop the mitigation procedure. The business restoration process of business companies in terms of buildings, facilities and lifelines have shown greater research interest. In this study, we investigated the restoration process of business sectors in East and South coastal region in Sri Lanka after the 2004 Indian Ocean Tsunami. A field survey was conducted in East and South coast of Sri Lanka, in order to study the affecting parameters to damage assessment in the restoration process of the business companies. The results of the questionnaire-based field survey are then compared with the statistical analysis results. Finally, the factors affecting the restoration process after the tsunami are identified. As a main conclusion, financial support could be the most important reason for delays in restoration. Moreover, it has been observed that the tsunami inundation level of higher than one meter may have had more effect concerning the damage to the structures and requires additional time for restoration than other areas.

  2. The influence of multifamily apartment building occupants on energy and water consumption - the preliminary results of monitoring and survey campaign

    Science.gov (United States)

    Bandurski, Karol; Hamerla, Miłosz; Szulc, Jowita; Koczyk, Halina

    2017-11-01

    Occupants' attitudes and behavior have a significant influence on energy and water consumption in buildings. To provide more robust solutions, energy efficient applications should consider occupant-building interaction. However, there is a question to be answered: which aspects of lodging and occupant behavior cause the most substantial increase in consumption of these mediums. Thus, the aim of this study is to investigate the influence of household characteristics and occupants' behavior on level and variability in utilities consumption. The study uses the results of a measuring campaign and the questionnaire. The measuring campaign was carried out to monitor the consumption of energy used for space heating and domestic hot water, as well as electricity, gas and water. The questionnaire specifically focused on household characteristics and occupants' behavior. The research was carried out in four apartment buildings, all consisting of more than 100 apartments. Data from approximately 100 households was gathered and analyzed; the survey's respond rate was almost 50%. A quantitative analysis of the results confirms the assumption that both household characteristics and occupants' behavior (e.g. the use of heating control) are important factors for utilities consumption. Further work with the obtained data is planned in terms of including of greater number of apartments, assessment of ventilation effectiveness, as well as analysis of heat transfer between the apartments.

  3. Populations of some molds in water-damaged homes may differ if the home was constructed with gypsum drywall compared to plaster

    Science.gov (United States)

    Starting in the 1940s, gypsum drywall began replacing plaster and lathe in the U.S. home construction industry. Our goal was to evaluate whether some mold populations differ in water- damaged homes primarily constructed with gypsum drywall compared to plaster. The dust samples fr...

  4. A study of oxidative stress induced by non-thermal plasma-activated water for bacterial damage

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Qian; Ma, Ruonan; Tian, Ying [Academy for Advanced Interdisciplinary Studies, Peking University, Beijing 100871 (China); Liang, Yongdong; Feng, Hongqing [College of Engineering, Peking University, Beijing 100871 (China); Zhang, Jue; Fang, Jing [Academy for Advanced Interdisciplinary Studies, Peking University, Beijing 100871 (China); College of Engineering, Peking University, Beijing 100871 (China)

    2013-05-20

    Ar/O{sub 2} (2%) cold plasma microjet was used to create plasma-activated water (PAW). The disinfection efficacy of PAW against Staphylococcus aureus showed that PAW can effectively disinfect bacteria. Optical emission spectra and oxidation reduction potential results demonstrated the inactivation is attributed to oxidative stress induced by reactive oxygen species in PAW. Moreover, the results of X-ray photoelectron spectroscopy, atomic absorption spectrometry, and transmission electron microscopy suggested that the chemical state of cell surface, the integrity of cell membrane, as well as the cell internal components and structure were damaged by the oxidative stress.

  5. A study of oxidative stress induced by non-thermal plasma-activated water for bacterial damage

    International Nuclear Information System (INIS)

    Zhang, Qian; Ma, Ruonan; Tian, Ying; Liang, Yongdong; Feng, Hongqing; Zhang, Jue; Fang, Jing

    2013-01-01

    Ar/O 2 (2%) cold plasma microjet was used to create plasma-activated water (PAW). The disinfection efficacy of PAW against Staphylococcus aureus showed that PAW can effectively disinfect bacteria. Optical emission spectra and oxidation reduction potential results demonstrated the inactivation is attributed to oxidative stress induced by reactive oxygen species in PAW. Moreover, the results of X-ray photoelectron spectroscopy, atomic absorption spectrometry, and transmission electron microscopy suggested that the chemical state of cell surface, the integrity of cell membrane, as well as the cell internal components and structure were damaged by the oxidative stress.

  6. Energy consumption of building related energy functions in houses and utility buildings

    International Nuclear Information System (INIS)

    Van Arkel, W.G.; Jeeninga, H.; Menkveld, M.; Ruijg, G.J.

    1999-11-01

    This study investigates the development of the use of electricity and natural gas in houses and buildings until 2010. For the domestic sector it is studied how much energy is used now and will be used in future for heating, for production of hot water, for lighting, for ventilation and for cooling. For different sorts of buildings (shops, hospitals, schools, offices, restaurants) it has been determined how much gas will be used for heating, for hot water production and by humidifiers. It has also been calculated how much electricity will be used for lighting, ventilation, cooling and humidifying. The influence of higher and lower energy prices on the amount of use has been studied. Experts have been asked to give their opinions on trends in the use of buildings and the role of new technologies. The influence of these ideas on the use of energy has been calculated. 44 refs

  7. Advanced fire prevention techniques for ITER-INDIA laboratory building, IPR

    International Nuclear Information System (INIS)

    Modi, D.V.; Channa Reddy, D.

    2016-01-01

    Just as air and water, survival of human life without fire is unimaginable. However, fire can be a boon as well as a bane. The ability to control the use of fire is an art towards improved industrial development. The same phenomenon is also applicable for research and development sector. Fire Safety is a key issue for any kind of research laboratories. Fire hazards in laboratories arise from the storage and use of flammable materials and electrical installations and from hazardous operations carried out there. The risk of damage due to fire depends on the combustible available, their physical arrangement, the geometry of the building, likelihood of the ignition, etc. The risk is also controlled by the fire protection measures in place, which relate to both fire prevention and fire control. (author)

  8. Monitoring Moisture Damage Propagation in GFRP Composites Using Carbon Nanoparticles

    Directory of Open Access Journals (Sweden)

    Ahmed Al-Sabagh

    2017-03-01

    Full Text Available Glass fiber reinforced polymer (GFRP composites are widely used in infrastructure applications including water structures due to their relatively high durability, high strength to weight ratio, and non-corrosiveness. Here we demonstrate the potential use of carbon nanoparticles dispersed during GFRP composite fabrication to reduce water absorption of GFRP and to enable monitoring of moisture damage propagation in GFRP composites. GFRP coupons incorporating 2.0 wt % carbon nanofibers (CNFs and 2.0 wt % multi-wall carbon nanotubes (MWCNTs were fabricated in order to study the effect of moisture damage on mechanical properties of GFRP. Water absorption tests were carried out by immersing the GFRP coupons in a seawater bath at two temperatures for a time period of three months. Effects of water immersion on the mechanical properties and glass transition temperature of GFRP were investigated. Furthermore, moisture damage in GFRP was monitored by measuring the electrical conductivity of the GFRP coupons. It was shown that carbon nanoparticles can provide a means of self-sensing that enables the monitoring of moisture damage in GFRP. Despite the success of the proposed technique, it might not be able to efficiently describe moisture damage propagation in GFRP beyond a specific threshold because of the relatively high electrical conductivity of seawater. Microstructural investigations using Fourier Transform Infrared (FTIR explained the significance of seawater immersion time and temperature on the different levels of moisture damage in GFRP.

  9. Localization of simulated damage on a steel beam from random vibrations

    Czech Academy of Sciences Publication Activity Database

    Bayer, Jan; Král, J.; Urushadze, Shota

    2018-01-01

    Roč. 62, č. 1 (2018), s. 112-116 ISSN 0553-6626 R&D Projects: GA ČR(CZ) GC17-26353J Institutional support: RVO:68378297 Keywords : damage localization * change of natural modes * flexibility matrix * flexibility curvatures * case study * damage detection * vibration monitoring Subject RIV: JM - Building Engineering OBOR OECD: Construction engineering, Municipal and structural engineering Impact factor: 0.313, year: 2016 https://pp.bme.hu/ci/ article /view/10625

  10. Muscle Damage Indicators after Land and Aquatic Plyometric Training Programmes

    Directory of Open Access Journals (Sweden)

    Vlatka Wertheimer

    2018-03-01

    Full Text Available Plyometric training is an important part of athletic conditioning with many significant benefits, including improved motor abilities and performance, but it can also increase the serum indices of muscle damage, collagen breakdown, muscle swelling, and soreness. Due to the physical characteristics of water, plyometric training in water presents less eccentric contraction, facilitates faster transition from the eccentric to concentric phase of a jump and offers greater resistance during concentric contraction with acute lower indices of muscle damage. To advance our understanding of the long-term effects of an eight-week plyometric training programme on land and in water on muscle damage indicators (lactate dehydrogenase (LDH, creatine kinase (CK and serum urea (SU, two experimental groups of physically active men (a group on land (EG1 and a group in water (EG2 were tested before and after the first and the last plyometric training to monitor muscle damage indicators and adaptations. The results showed changes in CK activity after both plyometric trainings for EG1 and only after the first training for EG2. Moreover, after the eight-week programme, significant difference was observed in CK activity in comparison with EG2. There were no observed changes in LDH activity while SU showed greater changes for the group on land. The plyometric training programme in water resulted in smaller levels of muscle damage indicators. Although both experimental groups conducted the same plyometric training with the same jump volume, the eccentric and concentric loads were not the same, so it can be concluded that adaptations in muscle damage processes are faster with smaller eccentric loads.

  11. Anisotropic 3D delay-damage model to simulate concrete structures

    OpenAIRE

    Gatuingt , Fabrice; Desmorat , Rodrigue; Chambart , Marion; Combescure , Didier; Guilbaud , Daniel

    2008-01-01

    International audience; High dynamic loadings lead to material degradation and structural failure. This is even more the case for concrete structures where the parts initially in compression break in ten- sion due to waves propagation and reflection. The dissymmetry of the material behavior plays a major role in such cases, dissymmetry mainly due to damage induced anisotropy. Loading induced damage is most often anisotropic and one proposes here to take advantage of such a feature to build a ...

  12. Passive systems for light water reactors

    International Nuclear Information System (INIS)

    Adinolfi, R.; Noviello, L.

    1990-01-01

    The paper reviews the most original concepts that have been considered in Italy for the back-fitting of the nuclear power plants in order to reduce the probability and the importance of the release to the environment in case of a core melt. With reference either to BWR or PWR, passive concepts have been considered for back-fitting in the following areas: pump seals damage prevention and ECCS passive operation; reactor passive depressurization; molten reactor core passive cooling; metal containment passive water cooling through a water tank located at high level; containment isolation improvement through a sealing system; containment leaks control and limitation of environmental release. In addition some considerations will be made on the protection against external events introduced from the beginning on the PUN design either on building and equipment lay-out either on structure design. (author). 5 figs

  13. Seismic strengthening of building 111 at Lawrence Livermore National Laboratory

    International Nuclear Information System (INIS)

    Eli, M.; Coats, D.; Freeland, G.; Kamath, M.

    1991-01-01

    Since being designed and constructed in the late 1960s, the Director's Building (Building 111) at Lawrence Livermore National Laboratory (LLNL) has been evaluated for 1988 seismic criteria and has been upgraded to withstand a major earthquake in the Livermore area. During and immediately after a large earthquake in the Livermore area, Building 111 occupants would be able to exit safely without loss of life. Building 111 itself would be severely damaged, but would not collapse. Highlights of the seismic upgrade design criteria and of the design, analyses, and construction that resulted are presented in this paper

  14. Antecedent conditions control carbon loss and downstream water quality from shallow, damaged peatlands.

    Science.gov (United States)

    Grand-Clement, E; Luscombe, D J; Anderson, K; Gatis, N; Benaud, P; Brazier, R E

    2014-09-15

    Losses of dissolved organic carbon (DOC) from drained peatlands are of concern, due to the effects this has on the delivery of ecosystem services, and especially on the long-term store of carbon and the provision of drinking water. Most studies have looked at the effect of drainage in deep peat; comparatively, little is known about the behaviour of shallow, climatically marginal peatlands. This study examines water quality (DOC, Abs(400), pH, E4/E6 and C/C) during rainfall events from such environments in the south west UK, in order to both quantify DOC losses, and understand their potential for restoration. Water samples were taken over a 19 month period from a range of drains within two different experimental catchments in Exmoor National Park; data were analysed on an event basis. DOC concentrations ranging between 4 and 21 mg L(-1) are substantially lower than measurements in deep peat, but remain problematic for the water treatment process. Dryness plays a critical role in controlling DOC concentrations and water quality, as observed through spatial and seasonal differences. Long-term changes in depth to water table (30 days before the event) are likely to impact on DOC production, whereas discharge becomes the main control over DOC transport at the time scale of the rainfall/runoff event. The role of temperature during events is attributed to an increase in the diffusion of DOC, and therefore its transport. Humification ratios (E4/E6) consistently below 5 indicate a predominance of complex humic acids, but increased decomposition during warmer summer months leads to a comparatively higher losses of fulvic acids. This work represents a significant contribution to the scientific understanding of the behaviour and functioning of shallow damaged peatlands in climatically marginal locations. The findings also provide a sound baseline knowledge to support research into the effects of landscape restoration in the future. Crown Copyright © 2014. Published by

  15. SYNER-G buildings, lifelines, transportation networks and critical facilities

    CERN Document Server

    Pitilakis, K; Kaynia, AM

    2014-01-01

    This volume collates serviceable fragility functions from an international selection of seismic risk probability research, developing and adapting them to a European context to improve damage forecasts for buildings, infrastructure, and critical facilities.

  16. Modelling multi-hazard hurricane damages on an urbanized coast with a Bayesian Network approach

    Science.gov (United States)

    van Verseveld, H.C.W.; Van Dongeren, A. R.; Plant, Nathaniel G.; Jäger, W.S.; den Heijer, C.

    2015-01-01

    Hurricane flood impacts to residential buildings in coastal zones are caused by a number of hazards, such as inundation, overflow currents, erosion, and wave attack. However, traditional hurricane damage models typically make use of stage-damage functions, where the stage is related to flooding depth only. Moreover, these models are deterministic and do not consider the large amount of uncertainty associated with both the processes themselves and with the predictions. This uncertainty becomes increasingly important when multiple hazards (flooding, wave attack, erosion, etc.) are considered simultaneously. This paper focusses on establishing relationships between observed damage and multiple hazard indicators in order to make better probabilistic predictions. The concept consists of (1) determining Local Hazard Indicators (LHIs) from a hindcasted storm with use of a nearshore morphodynamic model, XBeach, and (2) coupling these LHIs and building characteristics to the observed damages. We chose a Bayesian Network approach in order to make this coupling and used the LHIs ‘Inundation depth’, ‘Flow velocity’, ‘Wave attack’, and ‘Scour depth’ to represent flooding, current, wave impacts, and erosion related hazards.The coupled hazard model was tested against four thousand damage observations from a case site at the Rockaway Peninsula, NY, that was impacted by Hurricane Sandy in late October, 2012. The model was able to accurately distinguish ‘Minor damage’ from all other outcomes 95% of the time and could distinguish areas that were affected by the storm, but not severely damaged, 68% of the time. For the most heavily damaged buildings (‘Major Damage’ and ‘Destroyed’), projections of the expected damage underestimated the observed damage. The model demonstrated that including multiple hazards doubled the prediction skill, with Log-Likelihood Ratio test (a measure of improved accuracy and reduction in uncertainty) scores between 0.02 and 0

  17. Dynamic Analysis of AP1000 Shield Building Considering Fluid and Structure Interaction Effects

    Directory of Open Access Journals (Sweden)

    Qiang Xu

    2016-02-01

    Full Text Available The shield building of AP1000 was designed to protect the steel containment vessel of the nuclear reactor. Therefore, the safety and integrity must be ensured during the plant life in any conditions such as an earthquake. The aim of this paper is to study the effect of water in the water tank on the response of the AP1000 shield building when subjected to three-dimensional seismic ground acceleration. The smoothed particle hydrodynamics method (SPH and finite element method (FEM coupling method is used to numerically simulate the fluid and structure interaction (FSI between water in the water tank and the AP1000 shield building. Then the grid convergence of FEM and SPH for the AP1000 shield building is analyzed. Next the modal analysis of the AP1000 shield building with various water levels (WLs in the water tank is taken. Meanwhile, the pressure due to sloshing and oscillation of the water in the gravity drain water tank is studied. The influences of the height of water in the water tank on the time history of acceleration of the AP1000 shield building are discussed, as well as the distributions of amplification, acceleration, displacement, and stresses of the AP1000 shield building. Research on the relationship between the WLs in the water tank and the response spectrums of the structure are also taken. The results show that the high WL in the water tank can limit the vibration of the AP1000 shield building and can more efficiently dissipate the kinetic energy of the AP1000 shield building by fluid-structure interaction.

  18. A study of DNA damage in buccal cells of consumers of well- and/or tap-water using the comet assay: Assessment of occupational exposure to genotoxicants.

    Science.gov (United States)

    Vazquez Boucard, Celia; Lee-Cruz, Larisa; Mercier, Laurence; Ramírez Orozco, Martín; Serrano Pinto, Vania; Anguiano, Gerardo; Cazares, Linette; Díaz, Daniel

    2017-10-01

    Because of concerns that natural aquifers in the region of Todos Santos (Baja California Sur, Mexico) might be contaminated by organochlorine pesticides and heavy metals, a case-control study was conducted among consumers and non-consumers of well- and/or tap-water to determine risks to human health. This study was based on a genotoxic evaluation of buccal cells using the Comet assay technique. Levels of DNA damage in the consumers group were significantly higher than those of the control group. However, occupational exposure to genotoxicants showed to be the critical factor rather than water consumption. Taking into account the professions of well- and/or tap-water consumers, agricultural workers exposed directly (those who fumigated) or indirectly (those not involved in fumigating) to agrochemicals showed greater genetic damage than controls. This difference persisted even when age, and whether the person smoked or consumed alcoholic drinks were considered. These factors were not associated with the level of genetic damage observed. Chemical analyses of organochlorine pesticides and heavy metals were carried out to evaluate the water quality of wells, faucets, and surface water of canals consumed by the population and/or used for irrigation. High concentrations of α and β endosulfan were detected in water of surface canals. Although our inventory of agrochemicals employed in the region showed the use of products considered carcinogenic and/or mutagenic, they were not detected by the analytical techniques used. Heavy metals (arsenic, mercury, and lead) were detected in water of some wells used for irrigation and human consumption. Environ. Mol. Mutagen. 58:619-627, 2017. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  19. Experimental and numerical analysis of the cooling performance of water spraying systems during a fire.

    Directory of Open Access Journals (Sweden)

    YaoHan Chen

    Full Text Available The water spray systems are effective protection systems in the confined or unconfined spaces to avoid the damage to building structures since the high temperature when fires occur. NFPA 15 and 502 have suggested respectively that the factories or vehicle tunnels install water spray systems to protect the machinery and structures. This study discussed the cooling effect of water spray systems in experimental and numerical analyses. The actual combustion of woods were compared with the numerical simulations. The results showed that although the flame continued, the cooling effects by water spraying process within 120 seconds were obvious. The results also indicated that the simulation results of the fifth version Fire Dynamics Simulator (FDS overestimated the space temperature before water spraying in the case of the same water spray system.

  20. Diversity of ribosomal 16S DNA- and RNA-based bacterial community in an office building drinking water system.

    Science.gov (United States)

    Inkinen, J; Jayaprakash, B; Santo Domingo, J W; Keinänen-Toivola, M M; Ryu, H; Pitkänen, T

    2016-06-01

    Next-generation sequencing of 16S ribosomal RNA genes (rDNA) and ribosomal RNA (rRNA) was used to characterize water and biofilm microbiome collected from a drinking water distribution system of an office building after its first year of operation. The total bacterial community (rDNA) and active bacterial members (rRNA) sequencing databases were generated by Illumina MiSeq PE250 platform. As estimated by Chao1 index, species richness in cold water system was lower (180-260) in biofilms (Sphingomonas spp., Methylobacterium spp., Limnohabitans spp., Rhizobiales order) than in waters (250-580), (also Methylotenera spp.) (P = 0·005, n = 20). Similarly species richness (Chao1) was slightly higher (210-580) in rDNA libraries compared to rRNA libraries (150-400; P = 0·054, n = 24). Active Mycobacterium spp. was found in cross-linked polyethylene (PEX), but not in corresponding copper pipeline biofilm. Nonpathogenic Legionella spp. was found in rDNA libraries but not in rRNA libraries. Microbial communities differed between water and biofilms, between cold and hot water systems, locations in the building and between water rRNA and rDNA libraries, as shown by clear clusters in principal component analysis (PcoA). By using the rRNA method, we found that not all bacterial community members were active (e.g. Legionella spp.), whereas other members showed increased activity in some locations; for example, Pseudomonas spp. in hot water circulations' biofilm and order Rhizobiales and Limnohabitans spp. in stagnated locations' water and biofilm. rRNA-based methods may be better than rDNA-based methods for evaluating human health implications as rRNA methods can be used to describe the active bacterial fraction. This study indicates that copper as a pipeline material might have an adverse impact on the occurrence of Mycobacterium spp. The activity of Legionella spp. maybe questionable when detected solely by using DNA-based methods. © 2016 The Society for Applied