WorldWideScience

Sample records for watchmanlaa closure device

  1. 33 CFR 154.520 - Closure devices.

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Closure devices. 154.520 Section 154.520 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED... devices. (a) Except as provided in paragraph (b) of this section, each facility to which this part...

  2. Vascular Closure Devices in Interventional Radiology Practice.

    Science.gov (United States)

    Patel, Rafiuddin; Muller-Hulsbeck, Stefan; Morgan, Robert; Uberoi, Raman

    2015-08-01

    Manual compression (MC) is a well-established technique for haemostasis following percutaneous arterial intervention. However, MC is labour and time intensive with potential limitations, particularly for patients who are coagulopathic, unable to comply with bed rest or obese and when large sheaths or anti-coagulants are used. There are a variety of vascular closure devices (VCDs) available to overcome these limitations. This review gives an overview of current VCDs, their mechanism of action, individual strengths and weaknesses, evidence base and utility in interventional radiology (IR) practice. The majority of the published evidence on VCDs is derived from patients undergoing cardiac interventions, which should be borne in mind when considering the applicability and transfer of this data for general IR practice. Overall, the evidence suggests that most VCDs are effective in achieving haemostasis with a similar rate of complications to MC although the complication profile associated with VCDs is distinct to that of MC. There is insufficient evidence to comparatively analyse the different types of VCDs currently available or reliably judge their cost-effectiveness. The interventional radiologist should have a thorough understanding of the available techniques for haemostasis and be able to identify and utilise the most appropriate strategy and closure technique for the individual patient.

  3. Vascular Closure Devices in Interventional Radiology Practice

    Energy Technology Data Exchange (ETDEWEB)

    Patel, Rafiuddin, E-mail: rafiuddin.patel@ouh.nhs.uk [John Radcliffe Hospital, Department of Radiology (United Kingdom); Muller-Hulsbeck, Stefan, E-mail: muehue@diako.de [Diakonissen Hospital, Diagnostic and Interventional Radiology/Neuroradiology (Germany); Morgan, Robert, E-mail: robert.morgan@stgeorges.nhs.uk [St George’s Hospital, Department of Radiology (United Kingdom); Uberoi, Raman, E-mail: raman.uberoi@orh.nhs.uk [John Radcliffe Hospital, Department of Radiology (United Kingdom)

    2015-08-15

    Manual compression (MC) is a well-established technique for haemostasis following percutaneous arterial intervention. However, MC is labour and time intensive with potential limitations, particularly for patients who are coagulopathic, unable to comply with bed rest or obese and when large sheaths or anti-coagulants are used. There are a variety of vascular closure devices (VCDs) available to overcome these limitations. This review gives an overview of current VCDs, their mechanism of action, individual strengths and weaknesses, evidence base and utility in interventional radiology (IR) practice. The majority of the published evidence on VCDs is derived from patients undergoing cardiac interventions, which should be borne in mind when considering the applicability and transfer of this data for general IR practice. Overall, the evidence suggests that most VCDs are effective in achieving haemostasis with a similar rate of complications to MC although the complication profile associated with VCDs is distinct to that of MC. There is insufficient evidence to comparatively analyse the different types of VCDs currently available or reliably judge their cost-effectiveness. The interventional radiologist should have a thorough understanding of the available techniques for haemostasis and be able to identify and utilise the most appropriate strategy and closure technique for the individual patient.

  4. Current perspectives in percutaneous atrial septal defect closure devices

    Directory of Open Access Journals (Sweden)

    Bissessor N

    2015-07-01

    Full Text Available N Bissessor1–4 1Department of Cardiology, The Epworth Hospital, Melbourne, VIC, Australia; 2Division of Interventional Cardiology, The Alfred Hospital, Melbourne, VIC, Australia; 3Department of Clinical Science, Charles Sturt University Albury Campus, NSW, Australia; 4Heart Foundation, Griffith University, QLD, Australia Abstract: In the last decade, percutaneous atrial septal defect (ASD closure has become the treatment of choice in most clinical presentations of ASD. Percutaneous ASD closure has established procedural safety through operator experience and improved device structure and deliverability. There have also been advances in diagnostic capabilities. Devices have evolved from large bulky meshes to repositionable, minimal residual mesh content that easily endothelializes and conforms well to surrounding structures. Biodegradable technology has been introduced and will be closely watched as a future option. The evolution of ASD closure device usage in the last four decades incorporates development that minimizes a wide range of serious side effects that have been reported over the years. Complications reported in the literature include thrombus formation, air embolization, device embolization, erosions, residual shunts, and nickel hypersensitivity. Modern devices have intermediate to long term data with outcomes that have been favorable. Devices are available in multiple sizes with improved delivery mechanisms to recapture, reposition, and safely close simple and complex ASDs amenable to percutaneous closure. In this review, commonly used devices and deployment procedures are discussed together with a look at devices that show promise for the future. Keywords: ASD, congenital, Amplatzer, Gore Helex, Biostar, Figulla

  5. Suitability of Exoseal Vascular Closure Device for Antegrade Femoral Artery Puncture Site Closure

    Energy Technology Data Exchange (ETDEWEB)

    Schmelter, Christopher, E-mail: christopher.schmelter@klinikum-ingolstadt.de; Liebl, Andrea; Poullos, Nektarios [Klinikum Ingolstadt, Department of Diagnostic and Interventional Radiology (Germany); Ruppert, Volker [Klinikum Ingolstadt, Department of Vascular Surgery (Germany); Vorwerk, Dierk [Klinikum Ingolstadt, Department of Diagnostic and Interventional Radiology (Germany)

    2013-06-15

    Purpose. To assess the efficacy and safety of the Exoseal vascular closure device for antegrade puncture of the femoral artery. Methods. In a prospective study from February 2011 to January 2012, a total of 93 consecutive patients received a total of 100 interventional procedures via an antegrade puncture of the femoral artery. An Exoseal vascular closure device (6F) was used for closure in all cases. Puncture technique, duration of manual compression, and use of compression bandages were documented. All patients were monitored by vascular ultrasound and color-coded duplex sonography of their respective femoral artery puncture site within 12 to 36 h after angiography to check for vascular complications. Results. In 100 antegrade interventional procedures, the Exoseal vascular closure device was applied successfully for closure of the femoral artery puncture site in 96 cases (96 of 100, 96.0 %). The vascular closure device could not be deployed in one case as a result of kinking of the vascular sheath introducer and in three cases because the bioabsorbable plug was not properly delivered to the extravascular space adjacent to the arterial puncture site, but instead fully removed with the delivery system (4.0 %). Twelve to 36 h after the procedure, vascular ultrasound revealed no complications at the femoral artery puncture site in 93 cases (93.0 %). Minor vascular complications were found in seven cases (7.0 %), with four cases (4.0 %) of pseudoaneurysm and three cases (3.0 %) of significant late bleeding, none of which required surgery. Conclusion. The Exoseal vascular closure device was safely used for antegrade puncture of the femoral artery, with a high rate of procedural success (96.0 %), a low rate of minor vascular complications (7.0 %), and no major adverse events.

  6. Use of Amplatzer device for endobronchial closure of bronchopleural fistulas.

    Science.gov (United States)

    Kramer, Mordechai R; Peled, Nir; Shitrit, David; Atar, Eli; Saute, Milton; Shlomi, Dekel; Amital, Anat; Bruckheimer, Elchanan

    2008-06-01

    Bronchopulmonary fistula (BPF) is associated with high morbidity and mortality. It occurs as an uncommon but often severe complication of pneumonectomy. BPF may be treated by a range of surgical and medical techniques, including chest drain, Eloesser muscle flap, omental flap, transsternal bronchial closure, thoracoplasty, and prolonged therapy with antibiotic regimens. The use of bronchoscopy has been reported for the delivery of biological glue, coils, covered stents, and sealants. In this work, we describe a novel method of BPF closure using the Amplatzer device, which is commonly used for transcatheter closure of atrial septal defects.

  7. Device Closure of Small Ventricular Septal Defects: When and Why?

    Directory of Open Access Journals (Sweden)

    IB Vijayalakshmi

    2014-10-01

    Full Text Available Ventricular septal defect (VSD accounts for approximately 20-30 % of all forms of congenital heart disease (CHD. They were traditionally closed surgically in the past. The surgery though safe carries the risk of morbidity, complete heart block, wound infection and thoracotomy scar on the chest. On weighing the risk and benefit, the small VSDs were not submitted to surgery in the past. So for many years it has been taught that the small VSDs are to be left alone and surgery is not recommended. Many clinicians believed in spontaneous closure of VSDs. Hence they advised the parents to wait for spontaneous closure till the child is 9 years old. But what if the VSD does not close by 10 years is the question. Are they normal as grown up congenital heart (GUCH. The Jane Somerville GUCH unit showed that spontaneous closure occurred only in 10% between the age of 17 and 45 (mean - 27 years in small VSDs in adults. What is worth noting is about 25% had serious complications: infective endocarditis (11%, progressive aortic regurgitation (5%, age-related symptomatic arrhythmias (8.5% like atrial fibrillation. This means that asymptomatic small VSDs in childhood is not necessarily benign during adult life. This raises the question, when we have a safe non-surgical device closure available to close the small VSDs, should we put the future lives of the young in danger by not giving the benefit of technology to them?

  8. Minimally invasive retrieval of patent foramen ovale closure device after device migration to the descending aorta.

    Science.gov (United States)

    Basoor, Abhijeet S; Cotant, John F; Halabi, Abdul R; DeGregorio, Michele; Chughtai, Haroon; Patel, Kiritkumar C

    2012-01-01

    Percutaneous treatment of patent foramen ovale with a septal closure device has become a common procedure, but it is associated with various complications. Migration of the device is uncommon, and migration through the aortic valve into the aorta is rare. Managing the migration of a patent foramen ovale occluder can be challenging; it usually requires surgical retrieval of the foreign body. We report a rare case in which a patient experienced migration of a large patent foramen ovale closure device to the descending aorta. Rarer still was its successful percutaneous management.

  9. Vacuum with mesh is a feasible temporary closure device after fascial dehiscence

    DEFF Research Database (Denmark)

    Bjørsum-Meyer, Thomas; Skarbye, Mona; Jensen, Kenneth Højsgaard

    2013-01-01

    INTRODUCTION: The open abdomen is a challenging condition and a temporary abdominal closure device is required in order to protect the intra-abdominal viscera. We aimed to evaluate the feasibility of a recent device: vacuum-assisted wound closure and mesh-mediated fascial traction (VAWCM) after f...

  10. Vacuum with mesh is a feasible temporary closure device after fascial dehiscence

    DEFF Research Database (Denmark)

    Bjørsum-Meyer, Thomas; Skarbye, Mona; Jensen, Kenneth Højsgaard

    2013-01-01

    INTRODUCTION: The open abdomen is a challenging condition and a temporary abdominal closure device is required in order to protect the intra-abdominal viscera. We aimed to evaluate the feasibility of a recent device: vacuum-assisted wound closure and mesh-mediated fascial traction (VAWCM) after f...

  11. Patent foramen ovale closure using a bioabsorbable closure device: safety and efficacy at 6-month follow-up.

    Science.gov (United States)

    Van den Branden, Ben J; Post, Martijn C; Plokker, Herbert W; ten Berg, Jurriën M; Suttorp, Maarten J

    2010-09-01

    The aim of this study was to assess the mid-term safety and efficacy of percutaneous patent foramen ovale (PFO) closure using a bioabsorbable device (BioSTAR, NMT Medical, Boston, Massachusetts). Closure of PFO in patients with cryptogenic stroke has proven to be safe and effective using different types of permanent devices. All consecutive patients who underwent percutaneous PFO closure with the bioabsorbable closure device between November 2007 and January 2009 were included. Residual shunt was assessed using contrast transthoracic echocardiography. Sixty-two patients (55% women, mean age 47.7 ± 11.8 years) underwent PFO closure. The in-hospital complications were a surgical device retrieval in 2 patients (3.2%), device reposition in 1 (1.6%), and a minimal groin hematoma in 6 patients (9.7%). The short-term complications at 1-month follow-up (n = 60) were a transient ischemic attack in the presence of a residual shunt in 1 patient and new supraventricular tachycardia in 7 patients (11.3%). At 6-month follow-up (n = 60), 1 patient without residual shunt developed a transient ischemic attack and 1 developed atrial fibrillation. A mild or moderate residual shunt was noted in 51.7%, 33.9%, and 23.7% after 1-day, 1-month, and 6-month follow-up, respectively. A large shunt was present in 8.3%, 3.4%, and 0% after 1-day, 1-month, and 6-month follow-up. Closure of PFO using the bioabsorbable device is associated with a low complication rate and a low recurrence rate of embolic events. However, a relatively high percentage of mild or moderate residual shunting is still present at 6-month follow-up. Copyright © 2010 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  12. Transcutaneous closure of chronic broncho-pleuro-cutaneous fistula by duct occluder device

    Directory of Open Access Journals (Sweden)

    Vikas Marwah

    2016-01-01

    Full Text Available Bronchopleural fistula (BPF is a well known complication of several pulmonary conditions posing challenging management problem and is often associated with high morbidity and mortality. Though no consensus exists on a definite closure management algorithm, strategies for closure widely include various methods like tube thoracostomy with suction, open surgical closure, bronchoscopy directed glue, coiling and sealants which now also includes use of occlusion devices. We report a case in which a novel method of delivery and closure of recurrent post-operative broncho-pleuro-cutaneous fistula by a duct occluder device was done transcutaneously which has not been previously described in literature.

  13. MANTA, a novel plug-based vascular closure device for large bore arteriotomies: technical report.

    Science.gov (United States)

    van Gils, Lennart; Daemen, Joost; Walters, Greg; Sorzano, Todd; Grintz, Todd; Nardone, Sam; Lenzen, Mattie; De Jaegere, Peter P T; Roubin, Gary; Van Mieghem, Nicolas M

    2016-09-18

    Catheter-based interventions have become a less invasive alternative to conventional surgical techniques for a wide array of cardiovascular diseases but often create large arteriotomies. A completely percutaneous technique is attractive as it may reduce the overall complication rate and procedure time. Currently, large bore arteriotomy closure relies on suture-based techniques. Access-site complications are not uncommon and often seem related to closure device failure. The MANTA VCD is a novel collagen-based closure device that specifically targets arteriotomies between 10 and 22 Fr. This technical report discusses the MANTA design concept, practical instructions for use and preliminary clinical experience.

  14. Closure

    NARCIS (Netherlands)

    Stigter, C.J.

    1988-01-01

    At least an easier task than I have carried out the previous hour when we discussed the preliminary conclusions and recommendations has, as a compensation I guess, been given to me as well. To say a few words as a closure of this symposium. The beginning of such a series of closing statements is mos

  15. Percutaneous repair of iatrogenic subclavian artery injury by suture-mediated closure device

    Directory of Open Access Journals (Sweden)

    Rahul S Chivate

    2016-01-01

    Full Text Available Central venous catheterization through internal jugular vein is done routinely in intensive care units. It is generally safe, more so when the procedure is performed under ultrasound guidance. However, there could be inadvertent puncture of other vessels in the neck when the procedure is not performed under real-time sonographic guidance. Closure of this vessel opening can pose a challenge if it is an artery, in a location difficult to compress, and is further complicated by deranged coagulation profile. Here, we discuss the removal of an inadvertently placed catheter from subclavian artery with closure of arteriotomy percutaneously using arterial suture-mediated closure device.

  16. Gastrotomy closure with a new tissue anchoring device: A porcine survival study

    Institute of Scientific and Technical Information of China (English)

    Carlos Guarner-Argente; Henry Córdova; Graciela Martínez-Pallí; Ricard Navarro-Ripoll; Antonio Rodríguez-d'Jesús; Cristina Rodríguez de Miguel; Mireia Beltrán; Gloria Fernández-Esparrach

    2011-01-01

    AIM: To evaluate the feasibility, reproducibility and efficacy of a new tissue anchoring device in a porcine survival model.METHODS: Gastrotomies were performed using a needle-knife and balloon dilator in 10 female Yorkshire pigs weighing 30-35 kg. Gastric closure was attempted usinga new tissue anchoring device. The tightness of the closure was confirmed by means of air insufflation and the ability to maintain gastric distension with stability in peritoneal pressure measured with a Veress needle. All animals were monitored daily for signs of peritonitis and sepsis over 14 d. During necropsy, the peritoneal cavity and the gastric access site were examined.RESULTS: Transgastric access, closure and 14 d survival was achieved in all pigs. The mean closure timewas 18.1 ± 19.2 min and a mean of 2.1 ± 1 devices were used. Supplementary clips were necessary in 2 cases. The closure time was progressively reduced(24.8 ± 13.9 min in the first 5 pigs vs 11.4 ± 5.9 min in the last 5, P = NS). At necropsy, the gastric access site was correctly closed in all cases with all brace-bars present. One device was misplaced in the mesocolon.Minimal adhesions were observed in 3 pigs and signs of mild peritonitis and adhesions in one.CONCLUSIONS: The use of this new tissue anchoring device in porcine stomachs is feasible, reproducible and effective and requires a short learning curve.

  17. 16. Optimal guidance of percutaneous device closure of PDA by transthoracic echocardiography

    Directory of Open Access Journals (Sweden)

    M. Alobaidan

    2016-07-01

    Full Text Available Patent ductus arteriosus (PDA is common congenital cardiac lesion and the most accepted way of management is transcatheter occlusion by device which is usually done under fluoroscopy guidance. Transoesophageal echo cardiography and transaortic imaging were used in adult to guide the procedure which is with certain applications in pediatric age group transthoracic echocardiography (TTE in pediatric population provides excellent images for PDA and may replace the use of fluoroscopy to guide PDA closure at least in special situations. To highlight the feasibility of device closure under guidance of TTE to be applied in sick patients who are not suitable for transfer to cardiac catheter laboratory or those with contraindication to contrast and or radiation application. 18 patients from July 2013 to May 2015 underwent TTE guidance device closure of PDA, 1 patient was excluded after device embolization which necessitate retrieval under fluoroscopy (fluoro.. Conscious sedation was used in 17 patients except 1 who was sick and already ventilated in ICU, there were 11 female and 7 male, antegrade approach was used in 10 patients with partial fluoro and retrograde approach in 8 patients without fluoro. Median age is 7 months, median weight is 8 kg (3.2–11 kg, 2 patients with renal impairment, 2 with Leukemia, median procedure time is 35 min, median fluoro. is 2.2 min, PDA size were small in 13 patients and moderate in 5, immediate closure is achieved in all. The devices were ADOI, ADOS, ADOII, Occlutech, and AVP2. Device embolization in 1 with successful retrieval and second device was used with complete closure percutaneous PDA closure under TTE guidance is feasible, safe and recommended in selected patients with certain situation.

  18. Endobronchial closure of bronchopleural fistulae using amplatzer devices: our experience and literature review.

    Science.gov (United States)

    Fruchter, Oren; Kramer, Mordechai R; Dagan, Tamir; Raviv, Yael; Abdel-Rahman, Nader; Saute, Milton; Bruckheimer, Elchanan

    2011-03-01

    Bronchopulmonary fistulae (BPFs) are a severe complication of lobectomy and pneumonectomy and are associated with high rates of morbidity and mortality. We have developed a novel, minimally invasive method of central BPF closure using Amplatzer devices (ADs) that were originally designed for the transcatheter closure of cardiac defects. Ten patients with 11 BPFs (eight men and two women, aged 66.3±10.1 years [mean±SD]) were treated under conscious sedation with bronchoscopic closure of the BPFs using ADs. A nitinol double-disk occluder device was delivered under direct bronchoscopic guidance over a guidewire into the fistula. By extruding a disk on either side of the BPF, the fistula was occluded. Bronchography was performed by injecting contrast medium through the delivery sheath following the procedure to ensure correct device positioning. In nine patients, the procedure was successful and symptoms related to the BPF disappeared following closure by the AD. The results were maintained over a median follow-up period of 9 months. Therefore, we state that endobronchial closure using an AD is a safe and effective method for treatment of a postoperative BPF.

  19. Percutaneous suture-mediated closure of femoral access sites deployed through the procedure sheath: initial clinical experience with a novel vascular closure device.

    Science.gov (United States)

    Eggebrecht, Holger; Naber, Christoph; Woertgen, Uta; Ringe, Sonia; Konorza, Thomas F M; Schmermund, Axel; von Birgelen, Clemens; Haude, Michael; Kroeger, Knut; Erbel, Raimund; Baumgart, Dietrich

    2003-03-01

    The objective of this study was to assess the initial safety and feasibility of a novel suture-mediated device for closure of femoral access sites immediately after diagnostic or interventional cardiac catheterization. In a prospective study, 150 patients (mean age, 61.5 years; 109 male) underwent femoral access closure with a novel suture closure device (Superstitch, Sutura) immediately after diagnostic (n = 106) or interventional (n = 44) catheterization procedures, independently of the coagulation status. All patients were monitored for 24 hr after the procedure. The closure device was successfully deployed in 92% of patients. Immediate hemostasis was achieved in 77% of patients with no differences between patients undergoing diagnostic catheterization or coronary interventions (79% vs. 73%; P = 0.659). After 2 min of additional light manual compression, hemostasis was achieved in 92% of patients. There was one major complication requiring vascular surgery (0.7%). The novel suture closure device is a safe and effective device that allows for immediate closure of femoral puncture sites after both diagnostic and interventional procedures with a low rate of major complications.

  20. Use of OTSC Device System for Closure of Fistulas in the Alimentary Tract – A Case Series

    Directory of Open Access Journals (Sweden)

    Truptesh H. Kothari

    2014-01-01

    Conclusion: With several new devices being introduced, it is difficult to judge the implementation of one tool over the others. This device has shown promising results for fistula closure if used knowing the limitation of the product.

  1. First clinical experience with Celt ACD(®) : a femoral arterial puncture closure device.

    LENUS (Irish Health Repository)

    Jan, Aftab

    2013-08-01

    This prospective nonrandomized study compared the safety and efficacy of a novel arterial closure device (ACD) in common femoral artery procedures to that of the FDA submitted historical manual pressure control group, who underwent either a diagnostic angiogram (DA) or a percutaneous coronary intervention (PCI) procedure.

  2. [Magnetic urethral closure device. Negative outcome after implantation for the treatment of female urinary incontinence].

    Science.gov (United States)

    Anding, R; van Ahlen, H; Müller, S C; Latz, S

    2015-07-01

    We report on a negative outcome after implantation of a magnetic urethral closure device, consisting of one part screwed into the pubic bone and one part as a vaginal cone, for the treatment of urinary stress incontinence grade III. Continence was never achieved for the patient. The urethra narrowed over time due to erosion and scarring and the patient started intermittent catheterization, because spontaneous micturition was not possible. The magnet was broken, the bladder neck was eroded, several fragments were found in the bladder, and numerous fragments were scattered throughout the small pelvis. Surgery consisted of removing most of the fragments, followed by bladder neck closure and suprapubic diversion.

  3. Percutaneous left atrial appendage closure: Technical aspects and prevention of periprocedural complications with the watchman device

    Institute of Scientific and Technical Information of China (English)

    Sven; M?bius-Winkler; Nicolas; Majunke; Marcus; Sandri; Norman; Mangner; Axel; Linke; Gregg; W; Stone; Ingo; D?hnert; Gerhard; Schuler; Peter; B; Sick

    2015-01-01

    Transcatheter closure of the left atrial appendage has been developed as an alternative to chronic oral anticoagulation for stroke prevention in patients with atrial fibrillation, and as a primary therapy for patients with contraindications to chronic oral anticoagulation. The promise of this new intervention compared with warfarin has been supported by several, small studies and two pivotal randomized trial with the Watchman Device. The results regarding risk reduction for stroke have been favourable although acute complications were not infrequent. Procedural complications, which are mainly related to transseptal puncture and device implantation, include air embolism, pericardial effusions/tamponade and device embolization. Knowledge of nature, management and prevention of complications should minimize the risk of complications and allow transcatheter left atrial appendage closure to emerge as a therapeutic option for patients with atrial fibrillation at risk for cardioembolic stroke.

  4. Percutaneous atrial shunt closure using the novel Occlutech Figulla device: 6-month efficacy and safety.

    Science.gov (United States)

    Van Den Branden, Ben J L; Post, Martijn C; Plokker, Herbert W M; Ten Berg, Jurriën M; Suttorp, Maarten J

    2011-06-01

    The Occlutech Figulla Occluder is a new innovative device for percutaneous closure of a patent foramen ovale (PFO) and an atrial septum defect (ASD). We describe the safety and efficacy of this new device at 6-month follow-up. All 82 consecutive patients (51% female, mean age 49.0 ± 13.6 years) who underwent percutaneous PFO (n = 48) or ASD (n = 34) closure between October 2008 and October 2009 were included. Implantation success was 100%. The in-hospital complications were two new onset supraventricular tachycardia (SVT) (2.4%, both ASD patients), nine minimal groin hematoma's (11.0%, 4 PFO and 5 ASD patients), and one transient ST elevation during the procedure (1.2%, ASD patient). During 6 months follow-up (n = 79), no major complications or reoccurrences of cerebral thrombo-embolic events did occur. Seven patients (8.9%, 6 PFO and 1 ASD patient) experienced a new SVT. One patient developed a recurrent cerebral hemorrhage 5 months after ASD closure, which appeared not to be related to the procedure. Using contrast transthoracic echocardiography 6 months after PFO closure (n = 45), a residual shunt was present in 30.2% of the patients (small 25.6%, moderate 4.6%, severe 0%). In the ASD group (n = 34), a residual shunt was observed in 32.5% (small 17.7%, moderate 14.7%, severe 2.9%). The Occlutech Figulla Occluder appears to be easy to use, effective, and safe for percutaneous closure of PFO and ASD. We report a low complication rate but a relative high percentage of small residual shunts 6 months after closure. ©2010, Wiley Periodicals, Inc.

  5. Ultrasonographic features of vascular closure devices: initial and 6-month follow-up results

    OpenAIRE

    Hye Jung Choo; Hae Woong Jeong; Jin Young Park; Sung-Chul Jin; Sung Tae Kim; Jung Hwa Seo; Sun Joo Lee; Young Mi Park

    2014-01-01

    Purpose:

    This study aimed to evaluate the ultrasonographic findings for various types of vascular closure devices (VCDs) immediately after the angiographic procedure and at 6-month follow-up.

    Methods:

    We included 18 VCDs including Angio-Seal (n=4), FemoSeal (n=8), ExoSeal (n=3), Perclose (n=...

  6. Bailout transcatheter closure of patent foramen ovale for refractory hypoxaemia after left ventricular assist device implantation.

    Science.gov (United States)

    Fischer, Quentin; Kirsch, Matthias; Brochet, Eric; Juliard, Jean-Michel

    2015-08-01

    We describe the interdisciplinary management of a 59-year old man with ischaemic cardiomyopathy on a HeartMate II left ventricular assist device (LVAD) and temporary right extracorporeal membrane oxygenation (ECMO) as a bridge-to-heart transplantation. He suffered refractory hypoxaemia due to massive right-to-left shunting by a patent foramen ovale (PFO), diagnosed after weaning off of temporary right ECMO. Percutaneous closure of the PFO was successfully achieved with an Amplatzer septal occluder device, which allowed the patient's extubation and departure from hospital. The patient received heart transplantation 7 weeks after LVAD implantation and was discharged from the intensive care unit 2 weeks after transplantation.

  7. Transcatheter interruption of large residual flow after device closure of "Type A" patent ductus arteriosus

    Directory of Open Access Journals (Sweden)

    Anuradha Sridhar

    2012-01-01

    Full Text Available We report a case of 3-year-old girl who had persistence of large residual flow following transcatheter closure of a 6 mm ′Type A′ patent ductus arteriosus using a 12 × 10 mm duct occluder. Angiography revealed a large left-to-right shunt coursing through and exiting around the implanted device. Near total abolition of the residual shunt was achieved by initial implantation of an embolization coil within the duct occluder and subsequently an Amplatzer duct occluder (ADO II adjacent to the duct occluder. This challenging case describes an additional technique of abolishing a large residual flow in and around a Nitinol duct occluder device.

  8. Internal vacuum-assisted closure device in the swine model of severe liver injury

    Directory of Open Access Journals (Sweden)

    Everett Christopher B

    2012-12-01

    Full Text Available Abstract Objectives The authors present a novel approach to nonresectional therapy in major hepatic trauma utilizing intraabdominal perihepatic vacuum assisted closure (VAC therapy in the porcine model of Grade V liver injury. Methods A Grade V injury was created in the right lobe of the liver in a healthy pig. A Pringle maneuver was applied (4.5 minutes total clamp time and a vacuum assisted closure device was placed over the injured lobe and connected to suction. The device consisted of a perforated plastic bag placed over the liver, followed by a 15 cm by 15cm VAC sponge covered with a nonperforated plastic bag. The abdomen was closed temporarily. Blood loss, cardiopulmonary parameters and bladder pressures were measured over a one-hour period. The device was then removed and the animal was euthanized. Results Feasibility of device placement was demonstrated by maintenance of adequate vacuum suction pressures and seal. VAC placement presented no major technical challenges. Successful control of ongoing liver hemorrhage was achieved with the VAC. Total blood loss was 625 ml (20ml/kg. This corresponds to class II hemorrhagic shock in humans and compares favorably to previously reported estimated blood losses with similar grade liver injuries in the swine model. No post-injury cardiopulmonary compromise or elevated abdominal compartment pressures were encountered, while hepatic parenchymal perfusion was maintained. Conclusion These data demonstrate the feasibility and utility of a perihepatic negative pressure device for the treatment of hemorrhage from severe liver injury in the porcine model.

  9. Fluoroscopy-guided snare retrieval of the celt ACD(®) metallic vascular closure device following failed deployment.

    Science.gov (United States)

    Cahill, Thomas J; Choji, Kiyoshi; Kardos, Attila

    2014-03-01

    We report a case of endovascular snare retrieval of a new stainless steel vascular closure device (Celt ACD(®) , Kimal, Middlesex, UK) from the common femoral artery, following device failure after diagnostic coronary angiography. The stainless steel composition of the device aided successful fluoroscopic localization and removal.

  10. Transcatheter device closure of ruptured sinus of Valsalva: Immediate results and short term follow up

    Directory of Open Access Journals (Sweden)

    Sen Supratim

    2009-01-01

    Full Text Available This is a retrospective, observational study comprising of eight patients with isolated rupture of the sinus of Valsalva (RSOV who underwent transcatheter device closure. The mean age of presentation was 32.8 ± 10.0 years. New York Heart Association (NYHA class at the time of presentation was II (six patients and III (two patients. The RSOVs were all closed using a patent ductus arteriosus device. The mean procedural time was 42.3 ± 5.4 minutes, while the fluoroscopic time was 24.5 ± 6.9 minutes. All had complete closure of the shunt. The average hospital stay was 2.9 ± 1.1 days. There were no major complications. The patients were followed up for a mean of 11.3 ± 4.1 months. At the time of the last follow up all the patients were in NYHA class I. We conclude that in the short term, transcatheter closure of isolated RSOV is a viable alternative to surgical repair.

  11. Clinical experience with a circumferential clip-based vascular closure device in diagnostic catheterization.

    Science.gov (United States)

    Hermiller, James; Simonton, Charles; Hinohara, Tom; Lee, Daniel; Cannon, Louis; Mooney, Michael; O'Shaughnessy, Charles; Carlson, Harold; Fortuna, Richard; Yarbrough, Carol Anne; Zapien, Michael; Chou, Tony

    2005-10-01

    The StarClose Vascular Closure System (Abbott Vascular Devices, Redwood City, California) utilizes a small, flexible nitinol clip to complete a circumferential, extravascular closure of the femoral arteriotomy site. The StarClose is an investigational device in the United States, limited by Federal law to investigational use. The StarClose is CE Mark approved. The CLIP study was a prospective, randomized, multicenter trial utilizing a noninferiority design to compare the rate of major vascular complications and time-to-hemostasis using the StarClose system versus manual compression. A total of 596 subjects were enrolled, 208 of whom underwent diagnostic angiography. This diagnostic subset is the focus of this report. The primary safety endpoint was major vascular complications and the primary efficacy endpoint was time-to-hemostasis. All patients were followed at 30 days with a clinical exam. Subjects were randomized 2:1 to the StarClose (n = 136) or manual compression (n = 72). There were no major vascular complications in either group. Minor vascular complications occurred in 3 StarClose patients (2.2%), and 1 manual compression patient (1.4%) (p = 1.00). Use of the StarClose device reduced mean time-to-hemostasis from 15.47 +/- 11.4 to 1.46 +/- 4.5 minutes (p manual compression, and reduced the average time-to-ambulation from 269 +/- 135 to 163 +/- 105 minutes (p < or = 0.001). Device success was 94.1% (127/135), and procedural success was 100% (136/136). The clinical results of this study concluded that the StarClose Vascular Closure System is noninferior to standard compression with respect to the the primary safety endpoint of closing arteriotomies in patients who undergo percutaneous diagnostic procedures.

  12. Cardiac CT angiography for device surveillance after endovascular left atrial appendage closure.

    Science.gov (United States)

    Saw, Jacqueline; Fahmy, Peter; DeJong, Peggy; Lempereur, Mathieu; Spencer, Ryan; Tsang, Michael; Gin, Kenneth; Jue, John; Mayo, John; McLaughlin, Patrick; Nicolaou, Savvas

    2015-11-01

    Left atrial appendage (LAA) device imaging after endovascular closure is important to assess for device thrombus, residual leak, positioning, surrounding structures, and pericardial effusion. Cardiac CT angiography (CCTA) is well suited to assess these non-invasively. We report our consecutive series of non-valvular atrial fibrillation patients who underwent CCTA post-LAA closure with Amplatzer Cardiac Plug (ACP), Amulet (second generation ACP), or WATCHMAN devices. Patients underwent CCTA typically 1-6 months post-implantation. Prospective cardiac-gated CCTA was performed with Toshiba 320-detector or Siemens 2nd generation 128-slice dual-source scanners, and images interpreted with VitreaWorkstation™. GFR Amulet, 18 WATCHMAN). Average age was 75.5 ± 8.9 years, mean CHADS2 score 3.1 ± 1.3, and CHADS-VASc score 4.9 ± 1.6. All had contraindications to oral anticoagulation. Post-procedure, 41 (91.1%) were discharged on DAPT. There was one device embolization (ACP, successfully retrieved percutaneously) and one thrombus (WATCHMAN, resolved with 3 months of warfarin). There were two pericardial effusions, both pre-existing and not requiring intervention. Residual leak (patency) was seen in 28/44 (63.6%), and the mechanisms of leak were readily identified by CCTA (off-axis device, gaps at orifice, or fabric leak). Mean follow-up was 1.2 ± 1.1year, with no death, stroke, or systemic embolism. CCTA appears to be a feasible alternative to transoesophageal echocardiography for post-LAA device surveillance to evaluate for device thrombus, residual leak, embolization, position, and pericardial effusion. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2015. For permissions please email: journals.permissions@oup.com.

  13. Atrial septum defect closure device in a beating heart, from the perspective of a researcher in artificial organs.

    Science.gov (United States)

    Tomizawa, Yasuko

    2012-12-01

    Transcatheter closure of atrial septum defect (ASD) with a closure device is increasing, but the history of clinical use of this procedure is still short, and the efficacy and long-term safety remain unproved. The total number of closure devices implanted throughout the world has not been counted accurately. Therefore, the probability of complications occurring after implantation is uncertain. Device-related complications that occur suddenly late after implantation are life-threatening, and quite often necessitate emergency surgical intervention. In Japanese medical journals, authors reporting closure devices have mentioned no complications and problems in their facilities. Detailed studies of device-related complications and device removal have not been reported in Japan. In fact, this literature search found an unexpectedly large number of reports of various adverse events from many overseas countries. When follow-up duration is short and the number of patients is small, the incidence of complications cannot be determined. Rare complications may emerge in a large series with a long observation period. Consequently, the actual number of incidents related to ASD closure devices is possibly several times higher than the number reported. Guidelines for long-term patient management for patients with an implanted closure device are necessary and post-marketing surveillance is appropriate. Development of a national database, a worldwide registration system, and continuous information disclosure will improve the quality of treatment. The devices currently available are not ideal in view of reports of late complications requiring urgent surgery and the need for life-long follow-up. An ideal device should be free from complications during life, and reliability is indispensable.

  14. Long Term Outcome after Application of the Angio-Seal Vascular Closure Device in Minipigs

    OpenAIRE

    Kabelitz, Lisa; Nonn, Andrea; Nolte, Kay W.; Nikoubashman, Omid; Othman, Ahmed; Heringer, Sarah; Kramer, Martin; Wiesmann, Martin; Brockmann, Marc A.

    2016-01-01

    Minipigs are frequently used in (neuro-)interventional research. Longitudinal experiments may require repeated vessel access via the femoral artery. Anticoagulation and incompliance of the animals necessitates the use of a vascular closure device (VCD). The effects of the Angio-Seal VCD in minipigs were longitudinally assessed. Minipig (42±8.4 kg body weight) femoral arteries were sealed using the 8F (n = 6) or 6F (n = 7) Angio-Seal VCD. The pre-interventional femoral artery diameter was 5.1±...

  15. Left atrial appendage closure devices for cardiovascular risk reduction in atrial fibrillation patients

    Directory of Open Access Journals (Sweden)

    Cruz-Gonzalez I

    2015-05-01

    Full Text Available Ignacio Cruz-Gonzalez,* Juan Carlos Rama-Merchan,* Javier Rodriguez-Collado, Javier Martin-Moreiras, Alejandro Diego-Nieto, Antonio Arribas-Jimenez, Pedro Luís SanchezDepartment of Cardiology, University Hospital of Cardiology and IBSAL, Salamanca, Spain *Ignacio Cruz-Gonzalez and Juan Carlos Rama-Merchan have contributed equally to this work and should be considered co-first authors Abstract: Atrial fibrillation (AF is the most common sustained arrhythmia in clinical practice. AF is associated with a 4–5-fold increased risk of stroke and systemic embolism. Oral anticoagulant is the first-line therapy for this purpose, but it has various limitations and is often contraindicated or underutilized. Autopsy and surgical data have suggested that 90% of atrial thrombi in nonvalvular AF patients originate from the left atrial appendage, leading to the development of percutaneous closure for thromboembolic prevention. This paper examines the current evidence on left atrial appendage closure devices for cardiovascular risk reduction in AF patients. Keywords: atrial fibrillation, left atrial appendage, stroke, oral anticoagulant, percutaneous closure, thromboembolic prevention

  16. Transcatheter Atrial Septal Defect Closure Using Occlutech Figulla Device: A Two-Center Experience

    Directory of Open Access Journals (Sweden)

    Hojat Mortezaeian

    2015-10-01

    Full Text Available Background: Despite several reports regarding the use of the Occlutech Figulla® Flex septal occluder (OFFSO in adults, there are few reports on its use in children. We sought to study the result of the transcatheter closure of atrial septal defect (ASD using the OFFSO in children ≤ 12 years.Methods: We enrolled 45 consecutive patients, ranging from 2.5 to 12 years of age, in two large pediatric cardiovascular centers. All the children underwent complete echocardiographic examination before the procedure. Defect/device ratio and device/weight ratio were measured. The device diameter to the cardiac diameter ratio (DD/CD ratio in anteroposterior projection after device release and the DD/CD index were calculated by dividing the DD/CD ratio by the body surface area. Results: Of the 45 enrolled patients, 25 (55% were female. The range and mean ± standard deviation (SD of age were2.5 to 12 years and 6.8 ± 2.5 years, respectively. The range and mean ± SD weight were 8.5 to 37.0 kg and 19.7 ± 7.2 kg, respectively. Successful implantation was performed in all the patients. No major complications occurred in any of the subjects. We encountered one cobra head deformity in one patient. Neither residual shunt nor conduction abnormality was observed in any of the cases.Conclusion: Transcatheter ASD closure using the OFFSO was effective in our pediatric patients. Although this device needs relatively larger delivery sheaths, its use is safe while closing even large defects in children.

  17. Left atrial appendage closure: patient, device and post-procedure drug selection.

    Science.gov (United States)

    Tzikas, Apostolos; Bergmann, Martin W

    2016-05-17

    Left atrial appendage closure (LAAC), a device-based therapy for stroke prevention in patients with atrial fibrillation, is considered an alternative to oral anticoagulation therapy, particularly for patients at high risk of bleeding. Proof of concept has been demonstrated by the PROTECT AF and PREVAIL trials which evaluated the WATCHMAN device (Boston Scientific, Marlborough, MA, USA) versus warfarin, showing favourable outcome for the device group. The most commonly used devices for LAAC are the WATCHMAN and its successor, the WATCHMAN FLX (Boston Scientific) and the AMPLATZER Cardiac Plug and more recently the AMPLATZER Amulet device (both St. Jude Medical, St. Paul, MN, USA). The procedure is typically performed via a transseptal puncture under fluoroscopic and echocardiographic guidance. Technically, it is considered quite demanding due to the anatomic variability and fragility of the appendage. Careful material manipulation, adequate operator training, and good cardiac imaging and device sizing allow a safe, uneventful procedure. Post-procedure antithrombotic drug selection is based on the patient's history, indication and quality of LAAC.

  18. Live/Real Time Three-Dimensional Trans Esophageal Echocardiographic Findings in Amplatzer ASD Closure Devices in Adults

    Directory of Open Access Journals (Sweden)

    Fatemeh Nabavizadeh

    2012-09-01

    Full Text Available Six female patients aged from 19 to 73 years, with ostium secundum atrial septal defect underwent closure procedure with Amplatzer septal occluder device. Three-dimensional Echocardiography (3D-TEE was done during the procedure or one day after the procedure. 3D-TEE provides incremental value over Two- dimensional trans-esophageal echocardiography in measuring Amplatzer septal occluder disc sizes and correlates well with manufacture device size. 3D-TEE will surely prove to increase the technical efficiency and it will become an important tool for the interventionists for periprocedural evaluation of device closures.

  19. Device closure of post-myocardial infarction ventricular septal defect three weeks after coronary angioplasty

    Science.gov (United States)

    Patnaik, A. N.; Barik, Ramachandra; Kumari, N. Rama; Gulati, A. S.

    2012-01-01

    Percutaneus device closure appears to be safe and effective in patients treated for a residual shunt after initial surgical closure, as well as after two to three weeks of index myocardial infarction. The index case presented with a ventricular septal defect on second of acute myocardial infarction thrombolysed with streptokinase. The general condition of the patient was fairly stable. Cardiac catheterization and coronary angiography showed significant left to right shunt and there was 90 % proximal stenosis of left anterior descending coronary artery. Other coronary arteries were normal. Angioplasty and stenting to the coronary artery lesion was done using drug eluting stent (DES) with very good angiographic result. Patient was discharged after four days in stable condtion. After 3 weeks his ventricular septal defect was closed percutaneusly using cardio -O-fix device with tiny residual shunt. The procedure was uneventful and of brief duration. He was discharged after 5 days of the post procedure in very stable condition with minimal residual shunt. A staged procedure is a better option if the condition of the patient allows strengthening ventricular septal defect border. PMID:22629038

  20. Efficacy of femoral vascular closure devices in patients treated with anticoagulant, abciximab or thrombolytics during percutaneous endovascular procedures

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Ha Young; Choo, Sung Wook [Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of); Roh, Hong Gee [Konkuk University School of Medicine, Seoul (Korea, Republic of)] (and others)

    2006-03-15

    This study assessed the outcomes of using vascular closure devices following percutaneous transfemoral endovascular procedures in the patients who were treated with heparin, abciximab thrombolytics (urokinase or t-PA) during the procedures. From March 28, 2003 to August 31, 2004, we conducted a prospective and randomized study in which 1,676 cases of 1.180 patients were treated with one of the two different closure devices (the collagen plug device was Angio-Seal{sup TM.}, the suture-mediated closure device was The Closer S{sup TM}) at the femoral access site after instituting percutaneous endovascular procedures. Among the 1,676 cases, 108 cases (the drug group) were treated with heparin only (n=94), thrombolytics only (n=10), heparin and thrombolytics (n=3), or abciximab and thrombolytics (n=1) during the procedures; 1,568 cases (the no-drug group) were treated without any medication. We compared the efficacy and complications between the two groups. Of the drug group, 42 cases underwent arterial closures with the collagen plug devices and 66 cases underwent arterial closures with the suture-mediated closure devices. We also compared the efficacy and complications between these two group. The immediate hemostasis rates were 92.9% (1,456/1,568) in the no drug group and 91.7% (99/108) in the drug group. Early complications occurred in four cases of the drug group. These included two episodes of rebleeding with using the Closer S, which required manual compression for at least 10 minutes, and two episodes of minor oozing with using one Angio-Seal and one Closer S, which required two hours of additional bed rest. There was no late complication. So, the total success rates were 90.8% (1,423/1,568) in the no-drug group and 88.0% (95/108) in the drug group. These results were not significantly different between the two groups ({rho}=0.34). In the drug group, the difference of the successful hemostasis rate between the collagen plug devices and the suture

  1. The BioSTAR(r) device versus the CardioSEAL(r) device in patent foramen ovale closure: comparison of mid-term efficacy and safety.

    Science.gov (United States)

    Van den Branden, Ben J; Luermans, Justin G; Post, Martijn C; Plokker, Herbert W; Ten Berg, Jurriën M; Suttorp, Maarten J

    2010-09-01

    To compare the mid-term efficacy and safety of the bioabsorbable BioSTAR(r) device with the non-bioabsorbable CardioSEAL(r) device for percutaneous patent foramen ovale (PFO) closure. All 81 consecutive patients who underwent PFO closure with the CardioSEAL(r) or BioSTAR(r) device between June 2003 and July 2008 were included. The presence of a residual shunt (minimal, moderate or large) was measured in both groups at six months follow-up, using contrast transthoracic echocardiography. Forty-four patients (48.4±11.4 years) received the CardioSEAL(r) device and 37 patients the BioSTAR(r) device (47.9±10.7 years). There were no significant differences in short-term complications. Two patients who received the BioSTAR(r) device developed a recurrent transient cerebral ischaemic event. Overall, atrial arrhythmias occurred in 19%, with no difference between both groups. At six months, a residual shunt was present in 29% (27% minimal, 2% moderate) using the CardioSEAL(r) device compared to 28% (17% minimal, 11% moderate) using the BioSTAR(r) device (p=0.18). A predictor for residual shunt could not be found. There is no difference in safety and efficacy at six months between the CardioSEAL(r) and BioSTAR(r) device used for PFO closure. However, using the BioSTAR(r) device tends to be associated with a higher percentage of moderate shunting.

  2. Peratrial Device Closure of a Congenital Coronary Artery Fistula through a Right Parasternal Approach: Innovative Use of Available Technology.

    Science.gov (United States)

    Jia, Yanting; Hongxin, Li; Wenbin, Guo; Zhang, Haizhou; Zou, Chengwei

    2016-02-16

    Current treatments for congenital coronary artery fistulas (CAFs) include surgical obliteration and transcatheter occlusion. However, surgical techniques involve significant trauma. Transcatheter occlusion is performed under fluoroscopy and angiography, in which radiation injury is inevitable. We present a patient, with a CAF from the left coronary artery to the right atrium, who underwent peratrial device closure of the CAF with a right parasternal approach under transesophageal echocardiography guidance. Complete occlusion was achieved by a symmetric ventricular septal occluder. We suggest that peratrial device closure of a congenital coronary artery fistula through a right parasternal approach may be a safe and effective option.

  3. Left Atrial Appendage Closure Device With Delivery System: A Health Technology Assessment

    Science.gov (United States)

    Nevis, Immaculate; Falk, Lindsey; Wells, David; Higgins, Caroline

    2017-01-01

    Background Atrial fibrillation is a common cardiac arrhythmia, and 15% to 20% of those who have experienced stroke have atrial fibrillation. Treatment options to prevent stroke in people with atrial fibrillation include pharmacological agents such as novel oral anticoagulants or nonpharmacological devices such as the left atrial appendage closure device with delivery system (LAAC device). The objectives of this health technology assessment were to assess the clinical effectiveness and cost-effectiveness of the LAAC device versus novel oral anticoagulants in patients without contraindications to oral anticoagulants and versus antiplatelet agents in patients with contraindications to oral anticoagulants. Methods We performed a systematic review and network meta-analysis. We also conducted an economic literature review, economic evaluation, and budget impact analysis to assess the cost-effectiveness and budget impact of the LAAC device compared with novel oral anticoagulants and oral antiplatelet agents (e.g., aspirin). We also spoke with patients to better understand their preferences, perspectives, and values. Results Seven randomized controlled studies met the inclusion criteria for indirect comparison. Five studies assessed the effectiveness of novel oral anticoagulants versus warfarin, and two studies compared the LAAC device with warfarin. No studies were identified that compared the LAAC device with aspirin in patients in whom oral anticoagulants were contraindicated. Using the random effects model, we found that the LAAC device was comparable to novel oral anticoagulants in reducing stroke (odds ratio [OR] 0.85; credible interval [Cr.I] 0.63–1.05). Similarly, the reduction in the risk of all-cause mortality was comparable between the LAAC device and novel oral anticoagulants (OR 0.71; Cr.I 0.49–1.22). The LAAC device was found to be superior to novel oral anticoagulants in preventing hemorrhagic stroke (OR 0.45; Cr.I 0.29–0.79), whereas novel oral

  4. Perventricular device closure of residual muscular ventricular septal defects after repair of complex congenital heart defects in pediatric patients.

    Science.gov (United States)

    Zhu, Da; Tao, Kaiyu; An, Qi; Luo, Shuhua; Gan, Changping; Lin, Ke

    2013-01-01

    Residual muscular ventricular septal defects are surgical challenges, especially after the repair of complex congenital heart defects. We investigated perventricular device closure as a salvage technique in pediatric patients who had postoperative residual muscular ventricular septal defects. From February 2009 through June 2011, 14 pediatric patients at our hospital had residual muscular ventricular septal defects after undergoing surgical repair of complex congenital heart defects. Ten patients met our criteria for perventricular device closure of the residual defects: significant left-to-right shunting (Qp/Qs >1.5) or substantial hemodynamic instability (a defect ≥2 mm in size). The patients' mean age was 20.4 ± 13.5 months, and their mean body weight was 10 ± 3.1 kg. The median diameter of the residual defects was 4.2 mm (range, 2.5-5.1 mm). We deployed a total of 11 SQFDQ-II Muscular VSD Occluders (Shanghai Shape Memory Alloy Co., Ltd.; Shanghai, China) in the 10 patients, in accord with conventional techniques of perventricular device closure. The mean procedural duration was 31.1 ±9.1 min. We recorded the closure and complication rates perioperatively and during a 12-month follow-up period. Complete closure was achieved in 8 patients; 2 patients had persistent trivial residual shunts. No deaths, conduction block, device embolism, or other complications occurred throughout the study period. We conclude that perventricular device closure is a safe, effective salvage treatment for postoperative residual muscular ventricular septal defects in pediatric patients. Long-term studies with larger cohorts might further confirm this method's feasibility.

  5. Left atrial appendage closure using the Amulet device: an initial experience with the second generation amplatzer cardiac plug.

    Science.gov (United States)

    Lam, Simon Cheung Chi; Bertog, Stefan; Gafoor, Sameer; Vaskelyte, Laura; Boehm, Patrick; Ho, Raymond Wei Jian; Franke, Jennifer; Hofmann, Ilona; Sievert, Horst

    2015-02-01

    Aim of this study was to demonstrate the feasibility, safety, and short-term outcome of left atrial appendage (LAA) closure with a new generation LAA closure device. The Amulet device (AGA, St Jude Medical, Minneapolis, MN) is a new generation of the amplatzer cardiac plug (ACP), specifically designed for LAA closure. This new version is designed to facilitate the implantation process and minimize procedural or device-related complications. The device was implanted in 17 patients with nonvalvular atrial fibrillation (AF). Clinical data were obtained at baseline, during the procedure, at discharge, at 30 and 90 days. All devices were implanted successfully. Device sizes ranged from 20 mm to 31 mm. A 12 French (Fr) or 14 Fr delivery sheath was used depending on the selected device size. Full and partial recapture was performed in 1 case and 3 cases, respectively. There was 1 procedure-related pericardial effusion successfully managed with pericardiocentesis. There was no device embolization. The mean length of stay was 2.1 ± 0.3 days. At 90 days, there were no deaths, strokes, systemic thromboembolism, or bleeding complications. There was no device-related thrombus or pericardial effusion at 90-day TEE. In 2 of the 17 patients minimal peridevice flow (smaller than 2 mm) was present. The Amulet device, which has new novel features as compared with the first generation ACP, is a feasible option for LAA closure. From our initial experience, implantation of the Amulet is associated with high success rate and good short-term outcome. © 2014 Wiley Periodicals, Inc.

  6. Temporary abdominal closure with zipper-mesh device for management of intra-abdominal sepsis

    Directory of Open Access Journals (Sweden)

    Edivaldo Massazo Utiyama

    Full Text Available OBJECTIVE: to present our experience with scheduled reoperations in 15 patients with intra-abdominal sepsis. METHODS: we have applied a more effective technique consisting of temporary abdominal closure with a nylon mesh sheet containing a zipper. We performed reoperations in the operating room under general anesthesia at an average interval of 84 hours. The revision consisted of debridement of necrotic material and vigorous lavage of the involved peritoneal area. The mean age of patients was 38.7 years (range, 15 to 72 years; 11 patients were male, and four were female. RESULTS: forty percent of infections were due to necrotizing pancreatitis. Sixty percent were due to perforation of the intestinal viscus secondary to inflammation, vascular occlusion or trauma. We performed a total of 48 reoperations, an average of 3.2 surgeries per patient. The mesh-zipper device was left in place for an average of 13 days. An intestinal ostomy was present adjacent to the zipper in four patients and did not present a problem for patient management. Mortality was 26.6%. No fistulas resulted from this technique. When intra-abdominal disease was under control, the mesh-zipper device was removed, and the fascia was closed in all patients. In three patients, the wound was closed primarily, and in 12 it was allowed to close by secondary intent. Two patients developed hernia; one was incisional and one was in the drain incision. CONCLUSION: the planned reoperation for manual lavage and debridement of the abdomen through a nylon mesh-zipper combination was rapid, simple, and well-tolerated. It permitted effective management of severe septic peritonitis, easy wound care and primary closure of the abdominal wall.

  7. Predictors of Early (1-Week) Outcomes Following Left Atrial Appendage Closure With Amplatzer Devices.

    Science.gov (United States)

    Koskinas, Konstantinos C; Shakir, Samera; Fankhauser, Máté; Nietlispach, Fabian; Attinger-Toller, Adrian; Moschovitis, Aris; Wenaweser, Peter; Pilgrim, Thomas; Stortecky, Stefan; Praz, Fabien; Räber, Lorenz; Windecker, Stephan; Meier, Bernhard; Gloekler, Steffen

    2016-07-11

    The aim of this study was to assess predictors of adverse 1-week outcomes and determine the effect of left atrial appendage (LAA) morphology following LAA closure (LAAC) with Amplatzer devices. Percutaneous LAAC is a valuable treatment option for stroke prevention in patients with atrial fibrillation. Determinants of procedural safety events with Amplatzer occluders are not well established, and the possibly interrelating effect of LAA anatomy is unknown. Between 2009 and 2014, 500 consecutive patients with atrial fibrillation ineligible or at high risk for oral anticoagulation underwent LAAC using Amplatzer devices. Procedure- and device-related major adverse events (MAEs) were defined as the composite of death, stroke, major or life-threatening bleeding, serious pericardial effusion, device embolization, major access-site vascular complication, or need for cardiovascular surgery within 7 days following the intervention. Patients (mean age 73.9 ± 10.1 years) were treated with Amplatzer Cardiac Plug (n = 408 [82%]) or Amulet (n = 92 [18%]) devices. Early procedural success was 97.8%, and MAEs occurred in 29 patients (5.8%). Independent predictors of MAEs included device repositioning (odds ratio: 9.13; 95% confidence interval: 2.85 to 33.54; p < 0.001) and left ventricular ejection fraction <30% (odds ratio: 4.08; 95% confidence interval: 1.49 to 11.20; p = 0.006), with no effect of device type or size. Angiographic LAA morphology, characterized as cauliflower (33%), cactus (32%), windsock (20%), or chicken wing (15%), was not associated with procedural success (p = 0.51) or the occurrence of MAEs (p = 0.78). In this nonrandomized study, procedural success of LAAC using Amplatzer devices was high. MAEs within 7 days were predicted by patient- and procedure-related factors. Although LAA morphology displayed substantial heterogeneity, outcomes were comparable across the spectrum of LAA anatomies. Copyright © 2016 American College of Cardiology Foundation

  8. The Observation on Efficacy of Angio-seal Closure Device in the Femoral Arterial Puncture Site after PCI

    Institute of Scientific and Technical Information of China (English)

    Zhang Bin; Jin Lijun; Wei Shuishen; Fang Xianhong; Wu Handong; Dong Taiming; Yan hong; Liao Hongtao

    2006-01-01

    Objective To evaluatereliability and safety of Angio-seal hemostasis device applied to the femoral arterial puncture site after percutaneous coronary intervention (PCI). Methods In 40 patients after PCI in our institute during the period between May 2002 and December 2003, Angioseal device were used to seal the femoral arterial puncture site. Results All the Angioseal devices were successfully deployed in 40 patients (successful rate:100%); the mean time to hemostasis was 45±12 sec;the mean time to ambulate after angioseal closure was 1.9±0.5 hours. No major groin and systemic complication was observed. There was minor groin oozing in 2 cases and small hemotoma in 1 patient.Conclusions Angio-seal closure device of the femoral artery puncture site after a percutaneous coronary procedure is safe. It can shorten the time to hemostasis,leads to early mobilization, and reduce groin complication. The disadvantage is relatively expensive.

  9. The Angio-Seal™ femoral closure device allows immediate ambulation after coronary angiography and percutaneous coronary intervention

    DEFF Research Database (Denmark)

    Hvelplund, Anders; Jeger, Raban; Osterwalder, Remo;

    2011-01-01

    Aims: To test the safety of immediate mobilisation of patients undergoing coronary angiography and percutaneous coronary intervention (PCI) closed with Angio-Seal™ -a femoral vascular closure device. Methods and results: First, a randomised controlled trial of immediate mobilisation vs. delayed a...

  10. Endovascular repair of inadvertent arterial injury induced by central venous catheterization using a vascular closure device: A case report

    Energy Technology Data Exchange (ETDEWEB)

    Kim, So Hee; Jang, Woo Jin; Oh, Ju Heyon; Song, Yun Gyu [Samsung Changwon Hospital, Sungkyunkwan University School of Medicine, Changwon (Korea, Republic of)

    2017-04-15

    Central venous catheterization can cause various complications. Inadvertent subclavian artery catheterization was performed during insertion of a central venous catheter in a 73-year-old man suffering from panperitonitis due to small-bowel perforation. Endovascular treatment was conducted to treat the injured subclavian artery with a FemoSeal vascular closure device.

  11. Effect of biologically active coating on biocompatibility of Nitinol devices designed for the closure of intra-atrial communications

    NARCIS (Netherlands)

    Kong, XQ; Grabitz, RG; van Oeveren, W; Klee, D; van Kooten, TG; Freudenthal, F; Qing, M; von Bernuth, G; Seghaye, MC

    2002-01-01

    Anti-thrombogenicity and rapid endothelialisation are prerequisites for the use of closure devices of intra-atrial communications in order to reduce the risk of cerebral embolism. The purpose of this study was therefore to assess the effect of bioactive coatings on biocompatibility of Nitinol coils

  12. Usefulness of early diastolic mitral annular velocity to predict plasma levels of brain natriuretic peptide and transient heart failure development after device closure of atrial septal defect.

    Science.gov (United States)

    Masutani, Satoshi; Taketazu, Mio; Mihara, Chihiro; Mimura, Yuko; Ishido, Hirotaka; Matsunaga, Tamotsu; Kobayashi, Toshiki; Senzaki, Hideaki

    2009-12-15

    Device closure of atrial septal defect (ASD) is sometimes followed by elevation of plasma brain natriuretic peptide (BNP), a marker of heart failure, and progression to heart failure. This study tested the hypothesis that the underlying diastolic dysfunction, assessed on tissue Doppler images (TDI) before device closure, can predict BNP level after ASD closure. The study subjects were 39 consecutive patients (age 27.5 +/- 16.3 years, range 5 to 63) who underwent device closure for ASD. Echocardiographic evaluation using TDI and 2-dimensional and pulse wave Doppler were performed, together with plasma BNP measurement 1 day before and 2 days after ASD closure. Before ASD closure, an age-dependent decrease was noted in left ventricular relaxation, assessed by early diastolic mitral annular velocity. ASD closure resulted in a decrease in early diastolic mitral annular velocity (from 14.7 to 12.3 cm/s, p linear regression identified early diastolic mitral annular velocity before ASD closure and age as independent predictors of BNP levels after ASD closure (p annular velocity developed exertional dyspnea after the procedure. In conclusion, our results indicate that TDI measurements could be useful to detect underlying diastolic dysfunction that can potentially cause heart failure after ASD closure and emphasize the importance of ASD closure at a young age before impairment of left ventricular relaxation.

  13. An annulus fibrosus closure device based on a biodegradable shape-memory polymer network.

    Science.gov (United States)

    Sharifi, Shahriar; van Kooten, Theo G; Kranenburg, Hendrik-Jan C; Meij, Björn P; Behl, Marc; Lendlein, Andreas; Grijpma, Dirk W

    2013-11-01

    Injuries to the intervertebral disc caused by degeneration or trauma often lead to tearing of the annulus fibrosus (AF) and extrusion of the nucleus pulposus (NP). This can compress nerves and cause lower back pain. In this study, the characteristics of poly(D,L-lactide-co-trimethylene carbonate) networks with shape-memory properties have been evaluated in order to prepare biodegradable AF closure devices that can be implanted minimally invasively. Four different macromers with (D,L-lactide) to trimethylene carbonate (DLLA:TMC) molar ratios of 80:20, 70:30, 60:40 and 40:60 with terminal methacrylate groups and molecular weights of approximately 30 kg mol(-1) were used to prepare the networks by photo-crosslinking. The mechanical properties of the samples and their shape-memory properties were determined at temperatures of 0 °C and 40 °C by tensile tests- and cyclic, thermo-mechanical measurements. At 40 °C all networks showed rubber-like behavior and were flexible with elastic modulus values of 1.7-2.5 MPa, which is in the range of the modulus values of human annulus fibrosus tissue. The shape-memory characteristics of the networks were excellent with values of the shape-fixity and the shape-recovery ratio higher than 98 and 95%, respectively. The switching temperatures were between 10 and 39 °C. In vitro culture and qualitative immunocytochemistry of human annulus fibrosus cells on shape-memory films with DLLA:TMC molar ratios of 60:40 showed very good ability of the networks to support the adhesion and growth of human AF cells. When the polymer network films were coated by adsorption of fibronectin, cell attachment, cell spreading, and extracellular matrix production was further improved. Annulus fibrosus closure devices were prepared from these AF cell-compatible materials by photo-polymerizing the reactive precursors in a mold. Insertion of the multifunctional implant in the disc of a cadaveric canine spine showed that these shape-memory devices could be

  14. Pan-nitinol occluder and special delivery device for closure of patent ductus arteriosus: a canine-model feasibility study.

    Science.gov (United States)

    Jiang, Hai-bin; Bai, Yuan; Zong, Gang-jun; Han, Lin; Li, Wei-ping; Lu, Yang; Qin, Yong-wen; Zhao, Xian-xian

    2013-01-01

    The aim of this study was to evaluate a new type of occluder for patent ductus arteriosus. Patent ductus arteriosus was established in a canine model by anastomosing a length of autologous jugular vein to the descending aorta and the left pulmonary artery in an end-to-side fashion. Transcatheter closure of each patent ductus arteriosus was performed on 10 dogs, which were then monitored for as long as 6 months with aortography, echocardiography, and histologic evaluation. Transcatheter closure with use of the novel pan-nitinol device was successful in all canine models. Postoperative echocardiography showed that the location and shape of the occluders were normal, without any residual shunting. Further histologic evaluation confirmed that the occluder surface was completely endothelialized 3 months after implantation. Transcatheter patent ductus arteriosus closure with the pan-nitinol occluder can be performed safely and successfully in a canine model and shows good biological compatibility and low mortality rates.

  15. Percutaneous left atrial appendage closure devices: safety, efficacy, and clinical utility

    Directory of Open Access Journals (Sweden)

    Swaans MJ

    2016-09-01

    Full Text Available Martin J Swaans, Lisette IS Wintgens, Arash Alipour,  Benno JWM Rensing, Lucas VA Boersma Department of Cardiology, St. Antonius Hospital, Nieuwegein, the Netherlands Abstract: Atrial fibrillation (AF is the most common arrhythmia treated in the clinical practice. One of the major complications of AF is a thromboembolic cerebral ischemic event. Up to 20% of all strokes are caused by AF. Thromboembolic cerebral ischemic event in patients with AF occurs due to atrial thrombi, mainly from the left atrial appendage (LAA. Prevention of clot formation with antiplatelet agents and especially oral anticoagulants (­vitamin K antagonists or newer oral anticoagulants has been shown to be effective in reducing the stroke risk in patients with AF but has several drawbacks with (major bleedings as the most important disadvantage. Therefore, physical elimination of the LAA, which excludes the site of clot formation by surgical or percutaneous techniques, might be a good alternative. In this review, we discuss the safety, efficacy, and clinical utility of the Watchman™ LAA closure device. Keywords: stroke, left atrial appendage, prevention, atrial fibrillation

  16. Ultrasonographic features of vascular closure devices: initial and 6 month followup results

    Energy Technology Data Exchange (ETDEWEB)

    Choo, Hye Jung; Jeong, Hae Woong; Park, Jin Young; Kim, Sung Tae; Seo, Jung Hwa; Lee, Sun Joo; Park, Young Mi [Inje University Busan Paik Hospital, Inje University College of Medicine, Busan (Korea, Republic of); Jin, Sung Chul [Dept. of Neurosurgery, Inje University Haeundae Paik Hospital, Inje University College of Medicine, Busan (Korea, Republic of)

    2014-12-15

    This study aimed to evaluate the ultrasonographic findings for various types of vascular closure devices (VCDs) immediately after the angiographic procedure and at 6-month follow-up. We included 18 VCDs including Angio-Seal (n=4), FemoSeal (n=8), ExoSeal (n=3), Perclose (n=2), and StarClose (n=1) in this study. Four patients were implanted with 2 VCDs at the each side of bilateral femoral arteries, while the remaining 8 patients were inserted 1 VCD at the right femoral artery. Ultrasonography was performed within 10 days and at approximately 6 months after the angiographic procedure. Ultrasonographic morphology of the attached VCD and its relationship with the arterial wall were analyzed. Initial ultrasonography revealed the attached VCD as the relevant unique structure with successful deployment and hemostasis. Follow-up ultrasonography demonstrated partial absorption of hemostatic materials in cases of Angio-Seal (n=3), FemoSeal (n=5), and ExoSeal (n=3), changes in the soft tissue surrounding the femoral artery in case of Angio-Seal (n=1), arterial intimal hyperplasia in cases of FemoSeal (n=3), and no gross changes as compared with the initial ultrasonographic findings in cases of Perclose (n=2) and StarClose (n=1). Initial ultrasonographic evaluation reflected the unique structure of each VCD, with most of them being easily distinguishable. Follow-up ultrasonography revealed various changes in the affected vessels.

  17. Lessons learnt from a series of hemodynamic and interventional complications during pulmonary valvotomy and device closure of ventricular septal defect

    Directory of Open Access Journals (Sweden)

    Anil Kumar Singhi

    2015-01-01

    Full Text Available In an adolescent girl with coexistent valvar pulmonary stenosis (PS and muscular ventricular septal defect (VSD causing right to left shunt and severe cyanosis, a series of complications were encountered during transcatheter intervention. After balloon pulmonary valvotomy (BPV and device closure of the VSD, dynamic infundibular hypercontractility elevated the right ventricular (RV systolic pressures leading to embolization of the device into the left ventricle. During retrieval of the device from the left ventricular outflow tract (LVOT, there was injury to the atrioventricular nodal tissue resulting in transient complete heart block. Even though the device was successfully retrieved out from the right femoral arterial access, there was a retroperitoneal hematoma causing severe anemia. A combination of dynamic infundibular obstruction, intravascular volume depletion caused by hemorrhage, low oxygen carrying capacity due to anemia, and inotropes resulted in a life-threatening hypercyanotic spell. Once this combination of suicidal hypercontractile right ventricle, anemia, and dehydration was recognized; management of the pathophysiology resulted in recovery of the patient. On a subsequent day, device closure of the VSD was complicated by unstable device position, but was finally achieved by an innovative device stabilization technique. We propose to explain the basis of hemodynamic and procedural complications, their recognition, and management. During preparatory stage before interventions in patients with multiple defects, which are linked by strong hemodynamic interdependence, meticulous planning should be done and multiple untoward events should be foreseen. While a few complications were completely unanticipated, some others could have been predicted.

  18. Epicardial deployment of right ventricular disk during perventricular device closure in a child with apical muscular ventricular septal defect

    Directory of Open Access Journals (Sweden)

    Nageswara Rao Koneti

    2013-01-01

    Full Text Available We report a successful perventricular closure of an apical muscular ventricular septal defect (mVSD by a modified technique. An eight-month-old infant, weighing 6.5 kilograms, presented with refractory heart failure. The transthoracic echocardiogram showed multiple apical mVSDs with the largest one measuring 10 mm. perventricular device closure using a 12 mm Amplatzer mVSD occluder was planned. The left ventricular disk was positioned approximating the interventricular septum; however, the right ventricular (RV disk was deployed on the free wall of the RV due to an absent apical muscular septum and a small cavity at the apex. The RV disk of the device was covered using an autologous pericardium. His heart failure improved during follow-up.

  19. Network Meta-analysis of Randomized Trials on the Safety of Vascular Closure Devices for Femoral Arterial Puncture Site Haemostasis

    OpenAIRE

    Jun Jiang; Junjie Zou; Hao Ma; Yuanyong Jiao; Hongyu Yang; Xiwei Zhang; Yi Miao

    2015-01-01

    The safety of vascular closure devices (VCDs) is still debated. The emergence of more related randomized controlled trials (RCTs) and newer VCDs makes it necessary to further evaluate the safety of VCDs. Relevant RCTs were identified by searching PubMed, EMBASE, Google Scholar and the Cochrane Central Register of Controlled Trials electronic databases updated in December 2014. Traditional and network meta-analyses were conducted to evaluate the rate of combined adverse vascular events (CAVEs)...

  20. Safety and efficacy of the Perclose suture-mediated closure device following carotid artery stenting under clopidogrel platelet blockade

    Energy Technology Data Exchange (ETDEWEB)

    Zorger, Niels; Finkenzeller, Thomas; Lenhart, Markus; Hamer, Okka; Paetzel, Christian; Borisch, Inghita; Toepel, Ingolf; Feuerbach, Stefan; Link, Johann [University of Regensburg Klinikum, Franz-Josef-Strauss-Allee 11, 93042, Regensburg (Germany)

    2004-04-01

    The aim of this study was evaluation of a closure device (Perclose, Menlo Park, Calif.) for closure of the femoral artery access site in patients undergoing aggressive anticoagulation and platelet blockade after carotid stenting. Fifty-five patients who received clopidogrel in addition to aspirin and heparin as medication for carotid stenting were included for suture of the femoral access site after using 7- or 8-F guide catheters. The technical success, the time for suture, the clotting parameters, and complications were examined. Follow-up investigations, including ultrasound and clinical examinations, were performed. The groin was checked for possible hematoma, pseudoaneurysm, arteriovenous fistula, and local infection. Technical success was obtained in 51 of 54 patients (94%) after a mean procedure time of 6 min (range 5-10 min). The suture device was not used in one patient (2%) for anatomical reasons and failed to obtain hemostasis in 3 of 54 (6%) patients. In 4 of 54 patients (7%) bleeding was observed at the punctured site 4-6 h after intervention which was treated by a compression bandage. The mean dedicated activated clotting time was 137 s (range 29-287 s) before intervention and 349 s (150-958 s) just before deploying the Perclose device. During follow-up after 2 days (range 2-6 days) and 6 months no further complications of the puncture site were observed except for two large groin hematomas. No major complications occurred. Closure of the femoral access site after carotid stenting using a Perclose closure device is safe and effective even in patients receiving an aggressive anticoagulation and antiplatelet therapy. (orig.)

  1. Vacuum with mesh is a feasible temporary closure device after fascial dehiscence

    DEFF Research Database (Denmark)

    Bjørsum-Meyer, Thomas; Skarbye, Mona; Jensen, Kenneth Højsgaard

    2013-01-01

    fascial dehiscence focusing on fascial closure rate, mortality and procedure-related complications. MATERIAL AND METHODS: We performed a retrospective study on 18 patients treated with VAWCM after fascial dehiscence who were consecutively admitted to the Department of Surgery, Slagelse Hospital, between...... with a planned ventral hernia. We performed a retrospective follow-up with a median duration of 21 months 21% developed an incisional hernia. Two patients died within 60 days after closure of the abdomen. CONCLUSION: We found and that VAWCM is a safe and useful technique for delayed primary closure of the open...

  2. Tulip malformation of the left atrial disc in the Lifetech Cera ASD device: a novel complication of percutaneous ASD closure.

    Science.gov (United States)

    Hayes, Nicholas; Rosenthal, Eric

    2012-03-01

    A previously unreported tulip-like malformation of the left atrial disc was encountered during percutaneous closure of an atrial septal defect (ASD) using the LifeTech Cera ASD device, requiring snare assistance to permit recapture into the delivery sheath. This was likely to be as a result of attempting to recapture the left atrial disc whilst it remained in contact with some part of the atrial septum or left atrial wall. To help avoid this, it is recommended to ensure complete intracavity positioning of the Cera device prior to retrieval into the sheath. Copyright © 2011 Wiley Periodicals, Inc.

  3. Left atrial appendage closure device implantation and pulmonary vein isolation as a comprehensive treatment for atrial fibrillation

    Directory of Open Access Journals (Sweden)

    А. А. Якубов

    2016-01-01

    Full Text Available Objective. This randomized clinical trial was designed to assess the impact of pulmonary vein isolation (PVI combined with LAA occlusion on patients with high-risk AF. Methods. Patients with a history of symptomatic paroxysmal (P AF and/or persistent (Pers AF and CHA2DS2-VASc score ≥2 and HAS-BLED score ≥3 were randomized in groups with PVI only (n = 44 and PVI combined with LAA occlusion (n = 45. All patients were followed during 24 months in order to evaluate the safety of thromboembolic complications and to monitor the heart rhythm conducted by means of an implantable cardiac monitor. Results. 6 patients from the PVI with LAA occlusion group were transferred to the PVI only group because of a failure to implant a LAA closure device. Based on ILR data, by the end of the follow-up 33 (66% out of 50 patients in the PVI only group and 23 (59% out of 39 patients in the PVI with LAA closure device implantation group were free from atrial fibrillation and flutter without antiarrhythmic drugs (p = 0.34. In the blanking period, AF% was significantly higher in the PVI with LAA closure group than that in the PVI-only group, 9.7±10.8 and 4.2±4.1% respectively (p = 0.004. After the blanking period, the AF% was similar in both groups. During the entire follow-up, no AF/intervention-related complications were observed. Conclusion. The combination of LAA closure device implantation with PVI seems to be a safe procedure. However, it does not improve the efficacy of PVI in patients with symptomatic refractory AF. But in the blanking period LAA occlusion increases AF %.

  4. Comparison of outcome and complications using different types of devices for percutaneous closure of a secundum atrial septal defect in adults: a single-center experience.

    Science.gov (United States)

    Post, Martijn C; Suttorp, Maarten J; Jaarsma, Wybren; Plokker, H W Thijs

    2006-03-01

    The objective of this study was to find differences in outcome and complications using three different types of devices for percutaneous atrial septal defect (ASD) closure in adults. Percutaneous closure of a secundum-type ASD is increasingly performed in adult patients. All adult patients who underwent a percutaneous closure of a secundum-type ASD in our center between November 1996 and November 2004 were included. Failure was defined as dislocation or embolization of the device, which required surgical intervention. Periprocedural and mid-term complications were registered. Sixty-five patients, mean age 45.7+/-18.1 years (18 men, 47 women), underwent a percutaneous closure of an ASD with an ASDOS in 3, an Amplatzer in 36, and a Cardioseal/Starflex closure device in 26 patients. During an overall median follow-up of 1.2 years (range, 0.1-6.7 years), the failure occurred in four patients, all Cardioseal/Starflex (P=0.04). Within the Cardioseal/Starflex subgroup, the ASD and device diameters were significantly higher in those patients in whom the primary endpoint occurred compared to the others, 18.8+/-3.8 vs. 13.0+/-3.8 mm for ASD diameter (P=0.01) and 40 (range, 40-43) vs. 33 mm (range, 20-40) for device diameter (P=0.008). Overall complications were transient arrhythmias in 15.4%, pericardial effusion in 1.5%, and transient ischemic attack in 1.5%. Complete closure 6 months after the procedure occurred in 79.6%, without difference between the devices. Percutaneous ASD closure seems to be a relatively safe and effective procedure. However, using the larger Cardioseal/Starflex devices for closure seems to be related to a higher rate of device dislocation and embolization. Copyright (c) 2006 Wiley-Liss, Inc.

  5. First-in-man Percutaneous LAA Closure With an Amplatzer Amulet and TriGuard Embolic Protection Device in a Patient With LAA Thrombus.

    Science.gov (United States)

    Del Furia, Francesca; Ancona, Marco B; Giannini, Francesco; Jabbour, Richard J; Regazzoli, Damiano; Mangieri, Antonio; Latib, Azeem; Colombo, Antonio; Montorfano, Matteo

    2017-04-01

    Percutaneous left atrial appendage (LAA) closure is currently utilized for the prophylaxis of thromboembolic cerebrovascular accidents in patients with non-valvular atrial fibrillation. The presence of LAA thrombus is usually considered a contraindication for the procedure, since there is a high risk of thrombus embolization. While reports in the literature have shown the feasibility of LAA closure in the presence of LAA thrombus with certain cerebral embolic protection devices, we present the first-in-man LAA closure of a patient with LAA thrombus using the TriGuard Embolic Protection Device.

  6. Ease of Using a Dedicated Percutaneous Closure Device after Inadvertent Cannulation of the Subclavian Artery: Case Report

    Directory of Open Access Journals (Sweden)

    Arnaud Devriendt

    2009-01-01

    Full Text Available Inadvertent puncture of the subclavian artery is a relatively frequent and potentially disastrous complication of attempted central venous access. Due to its noncompressible location, accidental subclavian arterial cannulation may result in hemorrhage as the sheath is removed. We report a new case of successful percutaneous closure of the subclavian artery which had been inadvertently cannulated, using a closure device based on a collagen plug (Angio-Seal, St. Jude Medical. This was performed in a patient who had received maximal antiplatelet and anticoagulation therapies because of prior coronary stenting in the context of cardiogenic shock. There was no prior angiographic assessment, as arterial puncture was presumed to have been distal to the right common artery and vertebral arteries. No complications were observed in this high-risk patient, suggesting that this technique could be used once the procedure has been evaluated prospectively.

  7. 24h and 30 day outcome of Perclose Proglide suture mediated vascular closure device: An Indian experience.

    Science.gov (United States)

    Vinayakumar, Desabandhu; Kayakkal, Shajudeen; Rajasekharan, Sandeep; Thottian, Julian Johny; Sankaran, Prasanth; Bastian, Cicy

    Advantages of vascular closure device over manual compression include patient comfort, early mobilisation and discharge, avoidance of interruption of anticoagulation, avoidance of local compression and its sequelae and less time constraint on staff. No published Indian data exist regarding Perclose Proglide suture mediated vascular closure device (SMC). To study the 24h and 30 day outcome of Perclose Proglide SMC retrospectively. Retrospective observational study conducted in the Department of Cardiology, Government Medical College, Calicut, Kerala from June 2013 to June 2015. All consecutive patients with Perclose Proglide SMC deployment done by a single operator for achieving access site haemostasis where 24h and 30 day post-procedure data were available were included. Major and minor complications, procedure success, device failure were predefined. 323 patients were analysed. Procedure success rate was 99.7% (322/323). Transient oozing occurred in 44 patients (13.6%), minor and major complications occurred in 2% and 1.5% of patients respectively. Major complication included one case of retroperitoneal bleed, one access site infection, one pseudo aneurysm formation and two access site arterial stenosis. There was no death or complication requiring limb amputation. "Preclose" technique was used successfully in six patients. Primary device failure occurred in 12 cases which were tackled successfully with second Proglide in all except one. Perclose Proglide SMC is a safe and effective method to achieve haemostasis up to 22F with less complication rate. Copyright © 2016. Published by Elsevier B.V.

  8. Autologous platelet concentrate and vacuum-assisted closure device use in a nonhealing total knee replacement.

    Science.gov (United States)

    Klayman, Myra H; Trowbridge, Cody C; Stammers, Alfred H; Wolfgang, Gary L; Zijerdi, David A; Bitterly, Thomas J

    2006-03-01

    Following a total knee replacement surgery, a 51-year-old insulin-dependent patient presented with complications of impaired healing and postoperative trauma to the wound site. The inability of this leg wound to heal placed this patient at risk of amputation. Vacuum-assisted closure therapy was initiated at postoperative day 53; after 100 days of protracted wound history a series of treatments with topical platelet concentrates were added to the vacuum assisted closure therapy and conventional wound care therapy. The previous nonhealing wound presented with good granulation and margination that enabled a skin graft with good take on postoperative day 150.

  9. Transcatheter Closure of Atrial Septal Defect with Amplatzer Device in Children and Adolescents: Short and Midterm Results; an Iranian Experience

    Directory of Open Access Journals (Sweden)

    Saiyed-Habibollah Hosseini

    2011-06-01

    Full Text Available Objective:Transcatheter closure of secundum atrial septal defect (ASD with Amplatzer device is an alternative procedure to surgical repair, with some limitations. The aim of this study was to assess the initial and mid-term results of the treatment of ASD with Amplatzer septal occluder in children and adolescents. Methods:From May 2003 to January 2008 sixty three consecutive children and adolescent patients underwent transcatheter closure of ASD at a mean±SD age of 8.5±4.8 years (range 2.2 to 18 years. All procedures were performed under local anesthesia and moderate sedation or general anesthesia with transthoracic echocardiography and fluoroscopic guidance. Stretch diameter of ASD was determined by balloon sizing catheter. Device selection was based on and matched to the standard diameter of the septal defect. Follow up at 24 hours, 1 month, 6 months, 12 months and yearly thereafter included physical examination, electrocardiography and transthoracic echocardiography. Findings:The mean ASD diameter, measured with transthoracic echocardiography and balloon catheter were 19.5± 5.5 mm and 20.9± 6.2 mm, respectively. The mean follow up period was 32.4±18.8 months. Deployment of the device was successful in 57 (90.5% and failed in 6 (9.5% patients. The major complication included dislodgement of device in 1 patient and device embolization to right ventricular inlet (surgically removed in 1 patient. The minor complication included transient atrial tachycardia in 10 patients, paroxysmal supraventricular tachycardia in 2 patients during procedure, successfully terminated with medication. At 24 hour, 1 month, 6 month and 1 year follow up, total occlusion rates were 73.6 %, 91%, 94.7%, and 94.7%, respectively. Conclusion:Transcatheter occlusion of ASD with Amplatzer device is an effective and safe procedure with minimal complication rate and short hospital stay, as well as excellent short and intermediate outcome in children and adolescents.

  10. Obesity: An Independent Risk Factor for Insufficient Hemostasis Using the AngioSeal Vascular Closure Device After Antegrade Puncture

    Energy Technology Data Exchange (ETDEWEB)

    Minko, Peter, E-mail: peterminko@yahoo.com; Katoh, Marcus [University Hospital Saarland, Department of Diagnostic and Interventional Radiology (Germany); Graeber, Stefan [University Hospital Saarland, Institute of Medical Biometry, Epidemiology and Medical Informatics (Germany); Buecker, Arno [University Hospital Saarland, Department of Diagnostic and Interventional Radiology (Germany)

    2012-08-15

    Purpose: This study was designed to investigate the efficacy of the AngioSeal vascular closure device after antegrade puncture of the femoral artery. Methods: In a prospective study, 120 consecutive patients underwent lower limb vascular intervention by an antegrade access to the common femoral artery (CFA). After intervention, a 6F (n = 88) or an 8F (n = 32) AngioSeal vascular closure device was used to achieve hemostasis. The technical success or the cause of failure was documented. In addition, the coagulation status (platelets, INR, prothrombin time, atrial thromboplastin time (PTT)), hypertonus, locoregional habitus of the groin, body mass index (BMI), presence of calcifications, and history of previous surgical interventions of the CFA were evaluated. Results: Hemostasis was achieved in 97 patients (81%). In 12 patients (10%), persistent bleeding of the puncture site required manual compression. In another nine patients (8%) a kink of the sheath obviated the passage of the collagen plug toward the vessel, and in two patients the anchor dislodged out of the vessel, requiring manual compression. There were no significant differences between the groups of successful and unsuccessful sealing regarding the mean platelets (241 vs. 254 * 10{sup 9}/l; P = 0.86), INR (1.06 vs. 1.02; P = 0.52), prothrombin time (90% vs. 90%; P = 0.86), and PTT (30 vs. 31 s; P = 0.82). However, unsuccessful sealing was more likely in obese patients with an increased BMI (26.6 vs. 28.8 kg/m{sup 2}; P = 0.04). Conclusions: Obesity seems to be an independent risk factor for insufficient sealing using the AngioSeal vascular closure device after antegrade puncture of the CFA. In 8% of our patients, hemostasis could not be achieved due to kink of the flexible sheath.

  11. Safety and Efficacy of the Prostar XL Vascular Closing Device for Percutaneous Closure of Large Arterial Access Sites

    Directory of Open Access Journals (Sweden)

    Christoph Thomas

    2013-01-01

    Full Text Available Purpose. The purpose of this study is to retrospectively evaluate the efficacy and safety of the Prostar XL device for percutaneous large access site closure in an unselected patient and operator collective. Materials and Methods. All patients ( who had received percutaneous vascular closing with the Prostar XL device in our institution with follow-up data of at least 6 months were retrospectively included. Primary (freedom from surgical conversion and continued (freedom from groin surgery in further course technical success and major (deviations from expected outcome requiring surgery and minor (other deviations from expected outcome complications were assessed. Success and complications rates were correlated with delivery system size (Mann-Whitney Rank Sum Tests and operator experience (paired samples t-test. Results. Rates of primary and continued technical success as well as major and minor complications were 93.6%, 89.7%, 10.3%, and 10.3% (groin based and 90.0%, 84.0%, 16.0%, and 16.0% (patient based, respectively. No correlation of success and complications rate was found with delivery system sizes and operator experience. Conclusions. Application of the Prostar XL device for percutaneous closure of large arterial access sites is safe with a relatively high rate of technical success and low rate of major complications. Sizes of the delivery systems and the experience of the operator did not influence the results.

  12. Anomalous muscle bundle in the right atrium; Implication to trans atrial device closure

    Directory of Open Access Journals (Sweden)

    Saji Philip

    2017-09-01

    Full Text Available Intracavitary muscle bands or aberrant bands have been well described in all four chambers of the heart but rarely seen thick muscular band crossing right atrium. We report a case of devisable secundum atrial septal defect with an intra-atrial anomalous muscular band, crossing right atrial wall to the rim of the secundum atrial septal defect warranting surgical closure.

  13. A new cable-tie based sternal closure system: description of the device, technique of implantation and first clinical evaluation

    Directory of Open Access Journals (Sweden)

    Grapow Martin TR

    2012-06-01

    Full Text Available Abstract Background Wire closure still remains the preferred technique despite reasonable disadvantages. Associated complications, such as infection and sternal instability, cause time- and cost-consuming therapies. We present a new tool for sternal closure with its first clinical experience and results. Methods The sternal ZipFixTM System is based on the cable-tie principle. It primarily consists of biocompatible Poly-Ether-Ether-Ketone implants and is predominantly used peristernally through the intercostal space. The system provides a large implant-to-bone contact for better force distribution and for avoiding bone cut through. Results 50 patients were closed with the ZipFixTM system. No sternal instability was observed at 30 days. Two patients developed a mediastinitis that necessitated the removal of the device; however, the ZipFixTM were intact and the sternum remained stable. Conclusions In our initial evaluation, the short-term results have shown that the sternal ZipFixTM can be used safely and effectively. It is fast, easy to use and serves as a potential alternative for traditional wire closure.

  14. [Complications after the use of a StarClose® vascular closure device for femoral punctures].

    Science.gov (United States)

    Quintana Martínez, I; Guillén Subirán, M E; Zaragozano Guillén, R; Hilario González, J

    2014-01-01

    The StarClose(®) arterial device (Abbot Vascular Devices, Abbot Laboratories, Redwood City, CA, USA) rapidly seals a femoral artery puncture by means of a nitinol clip in the adventitia of the artery. It is a safe and effective device, with advantages as regards manual compression, but is not free of complications. We present two cases with complications after using a StarClose(®) vascular device.

  15. Immediate and short-term outcomes after percutaneous atrial septal defect closure using the new nit-occlud ASD-R device.

    Science.gov (United States)

    Peirone, Alejandro; Contreras, Alejandro; Ferrero, Adolfo; da Costa, Rodrigo Nieckel; Pedra, Simone Fontes; Pedra, Carlos A C

    2014-09-01

    To evaluate the feasibility, safety, and efficacy of implantation of the new Nit Occlud ASD-R® (NOASD-R) device for percutaneous closure of ostium secundum atrial septal defects (ASD-OS). Device catheter implantation has become the method of choice for most patients with ASD-OS. No single device has proven to be ideal for this type of procedure. The NOASD-R has a distinct design that may help to overcome limitations of other devices. A prospective, single arm, observational study including all consecutive patients receiving the NOASD-R device for ASD-OS closure between October 2011 and September 2013 was performed. Patient selection, device design, deployment technique, complications, and procedural outcomes were evaluated. Seventy-four patients underwent attempted transcatheter ASD-OS closure using the NOASD-R device. Implantation of the occluder was successful in 73 patients (98.6%). The majority of patients were female (79.5%) with a median age of 17.2 years (range: 2-74). A 2-D transthoracic color-Doppler echocardiogram (TTE) obtained at the 3 or 6 month follow-up visit showed complete occlusion of the ASD-OS in 72/73 patients (98.6%). At a mean follow-up interval of 11.4 ± 6.8 months there have been no episodes of late device embolization, cardiac perforation or erosion, endocarditis, thromboembolism, wire fracture, embolic neurologic events, or death. We report the first worldwide clinical experience using the NOASD-R device for ASD-OS closure. The procedure was feasible, with a high rate of successful implantations, and safe. High ASD-OS closure rates and no complications were encountered during short-term follow-up. © 2014 Wiley Periodicals, Inc. © 2014 Wiley Periodicals, Inc.

  16. Simple excision and closure of a distal limb of loop colostomy prolapse by stapler device.

    Science.gov (United States)

    Masumori, K; Maeda, K; Koide, Y; Hanai, T; Sato, H; Matsuoka, H; Katsuno, H; Noro, T

    2012-04-01

    Stomal prolapse is one of the common complications in transverse colostomy and can be managed conservatively in most cases; however, laparotomy and reconstruction of the stoma may sometimes be required, especially in case of irreducible colostomy prolapse. We have reported a simple local repair with reconstruction of the loop colostomy. We herein report a new more simple technique to avoid laparotomy and allow excision of the irreducible colostomy prolapse and complete closure of the distal limb of loop colostomy when no decompression is required in the distal limb of the stoma. In this procedure, the number of stapler and the time with blood loss for the operation can be saved.

  17. Safety and efficacy of femoral artery closure with the FemoSeal(R) device after coronary angiography using a 7 French sheath.

    Science.gov (United States)

    Wanitschek, M M; Suessenbacher, A; Dörler, J; Pachinger, O; Moes, N; Alber, H F

    2011-09-01

    Post-cardiac catheterization femoral artery hemostasis can be accomplished with several mechanisms, including the FemoSeal® hemostasis device which has been designed and approved for closure of 6 French (F) arterial puncture sites. The aim of this study was to investigate whether the FemoSeal® vascular closure device can effectively and safely seal 7F arterial puncture sites after diagnostic and interventional cardiac catheterizations. Femoral artery puncture sites of 50 consecutive patients undergoing cardiac catheterization were closed with the FemoSeal® vascular closure device, according to the manufacturer's instructions. Efficacy endpoints were time to hemostasis and successful ambulation. Safety endpoints included bleeding complications, vessel occlusion and pseudoaneurysms. Mean time to hemostasis was 57.8±26.3 seconds (0-125 seconds). Hemostasis was achieved in 100 percent of the 50 patients. One patient suffered minor bleeding the next day, i.e. local hematoma. This clinical study demonstrates that the FemoSeal® vascular closure device, initially approved for closure of 6F arterial puncture sites, shows promising efficacy and safety to seal a larger (7F) femoral arterial puncture sites after diagnostic and interventional cardiac catheterizations.

  18. Cardiac Plug I and Amulet Devices: Left Atrial Appendage Closure for Stroke Prophylaxis in Atrial Fibrillation.

    Science.gov (United States)

    Parashar, Akhil; Tuzcu, E Murat; Kapadia, Samir R

    2015-01-01

    Percutaneous left atrial appendage (LAA) occlusion has emerged as an exciting and effective modality for stroke prophylaxis in patients with non-valvular atrial fibrillation who are deemed too high risk for anticoagulation with warfarin or newer anticoagulants. The Amplatzer devices have been used in LAA occlusion for more than a decade, starting with off label use of an atrial septal occluder device for LAA occlusion. This was followed by introduction of a dedicated Amplatzer cardiac plug (ACP) 1 for LAA occlusion, and more recently, the second generation Amulet device, with reported better stability enhancing features, has been introduced. Both these devices are widely used outside the United States, however in the US only the WATCHMAN device has been FDA approved. Unlike the WATCHMAN device, where the evidence is continuously building as the data from two pivotal randomized controlled trials are emerging, most of the evidence for ACP devices is from pooled multicenter registry data. In this article, we review the device design, implantation techniques and the most recently published evidence for both the Amplatzer cardiac plug 1 and the newer Amulet device. Our goal is to summarize the most recent literature and discuss the current role of the Amplatzer devices in the exciting and rapidly growing field of percutaneous LAA occlusion.

  19. Prospective comparison of collagen plug (angio-seal{sup TM}) and suture-mediated (the closer S{sup TM}) closure devices at femoral access sites

    Energy Technology Data Exchange (ETDEWEB)

    Park, Yulri; Roh, Hong Gee; Choo, Sung Wook; Lee, Sung Hoon; Shin, Sung Wook; Do, Young Soo; Byun, Hong Sik; Park, Kwang Bo; Jeon, Pyoung [Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of)

    2005-12-15

    Rapid and effective hemostasis at femoral puncture sites minimizes both the hospital stay and patient discomfort. Therefore, a variety of arterial closure devices have been developed to facilitate the closure of femoral arteriotomy. The objective of this prospective study was to compare the efficacy of two different closure devices; a collagen plug device (Angio-Seal) and a suture-mediated closure device (the Closer S). From March 28, 2003 to August 31, 2004, we conducted a prospective study in which 1,676 cases of 1,180 patients were treated with two different types of closure device. Angio-Seal was used in 961 cases and the Closer S in 715 cases. The efficacy of the closure devices was assessed, as well as complications occurring at the puncture sites. Successful immediate hemostasis was achieved in 95.2% of the cases treated with Angio-Seal, and in 89.5% of the cases treated with the Closer S ({rho} < 0.05). The rates of minor and major complications occurring between the two groups were not significantly different. In the Closer S group, we observed four major complications (0.6%), that consisted of one massive retroperitoneal hemorrhage (surgically explored) and three pseudoaneurysms. In the Angio-Seal group, we observed three major complications (0.3%) that consisted of one femoral artery occlusion, one case of infection treated with intravenous antibiotics and one pseudoaneurysm. The use of Angio-Seal was found to be more effective than that of the Closer S with regard to the immediate hemostasis of the femoral puncture sites. However, we detected no significant differences in the rate at which complications occurred.

  20. Use of a home vacuum-assisted closure device in the burn population is both cost-effective and efficacious.

    Science.gov (United States)

    Mushin, Oren P; Bogue, Jarrod T; Esquenazi, Mica D; Toscano, Nicole; Bell, Derek E

    2017-05-01

    The vacuum assisted closure device (VAC) improves wound-healing when utilized as a bolster to secure split thickness skin grafts (STSG). Patients typically remain hospitalized for VAC therapy; however, home VACs (hVAC) are now available. Limited studies examine burns treated with hVAC as a STSG bolster. A retrospective study of records from an ABA verified regional burn center was conducted over 23 months. Patients included STSGs for burn. Data points included demographics, burn mechanism and location, graft characteristics, hospital length of stay (LOS), and time to heal. Fifty patients were included, with average age of 39 years (range hVAC over the same period. The hVAC is a cost-effective STSG bolster in the burn population for appropriate candidates. Excellent graft-take and low morbidity rates imply that this is an efficacious alternative for STSG bolster. Copyright © 2016 Elsevier Ltd and ISBI. All rights reserved.

  1. Patient Satisfaction After Femoral Arterial Access Site Closure Using the ExoSeal{sup ®} Vascular Closure Device Compared to Manual Compression: A Prospective Intra-individual Comparative Study

    Energy Technology Data Exchange (ETDEWEB)

    Pieper, Claus Christian, E-mail: claus.christian.pieper@ukb.uni-bonn.de; Thomas, Daniel, E-mail: daniel.thomas@ukb.uni-bonn.de [University of Bonn, Department of Radiology (Germany); Nadal, Jennifer, E-mail: jennifer.nadal@ukb.uni-bonn.de [University of Bonn, Institute for Medical Biometry, Informatics and Epidemiology (Germany); Willinek, Winfried A., E-mail: w.willinek@bk-trier.de; Schild, Hans Heinz, E-mail: hans.schild@ukb.uni-bonn.de; Meyer, Carsten, E-mail: carsten.meyer@ukb.uni-bonn.de [University of Bonn, Department of Radiology (Germany)

    2016-01-15

    PurposeTo intra-individually compare discomfort levels and patient satisfaction after arterial access closure using the ExoSeal{sup ®} vascular closure device (VCD) and manual compression (MC) in a prospective study design.MethodsPatients undergoing two planned interventions from 07/2013 to 09/2014 could participate in the study. Access closure was performed with an ExoSeal{sup ®}-VCD in one and MC in the other intervention. Patients were clinically and sonographically examined and were given questionnaires 1 day after intervention [groin- and back-pain during bedrest (100-point visual analog scale; 0: no pain); comfortability of bedrest (10-point Likert scale, 1: comfortable), satisfaction with closure (10-point Likert scale, 1: very satisfied)]. Results were analyzed in a cross-over design.Results48 patients (29 male, median age 62.5 (32–88) years) were included. An ExoSeal{sup ®}-VCD was used first in 25 cases. As four of these subsequently refused MC as second intervention, data from 44 patients could be analyzed. All closures were technically successful (successful device deployment) without major complications. Groin- and back-pain after VCD-use/MC was 0 (0–15) vs. 10 (0–80) and 0 (0–75) vs. 25 (0–90), respectively (p < 0.0001). Bedrest after VCD-use was more comfortable than after MC [1 (range 1–7) vs. 6 (2–10); p < 0.0001]. Satisfaction with the closure procedure and with the intervention in general was higher after VCD-use compared to MC [1 (1–3) vs. 5 (2–10) and 1 (1–2) vs. 2 (1–4), respectively; p < 0.0001].ConclusionIntra-individual comparison showed pain levels and discomfort to be significantly lower after ExoSeal{sup ®} use compared to MC. VCD closure was associated with higher satisfaction both with the closure itself and with the intervention in general.

  2. A novel method of creation of a fenestration in nitinol occluder devices used in closure of hypertensive patent arterial ducts

    Directory of Open Access Journals (Sweden)

    Anil Kumar Singhi

    2016-01-01

    Full Text Available Test occlusion with a balloon is done to predict operability of large hypertensive patent ductus arteriosus (PDA. If the fall in the pulmonary artery pressures is inadequate, a complete closure is not desired. To create a predictable premeasured fenestration in a nitinol occluder device used for closing hypertensive PDA. A large nitinol occluder device was punctured with an 18G needle to advance a 0.035½ stiff guide wire through the occluder before loading it into the delivery system. The occluder with the guidewire was then deployed across the PDA. A coronary guide catheter was later threaded through the guidewire into the fabric of the device, which was still held by the delivery cable. A coronary stent was deployed across the fenestration in the occluder to keep it patent. An 8-year-old boy with Down syndrome and hypertensive PDA was hemodynamically assessed. Even though there was a fall in the pulmonary vascular resistance index and pressures on test occlusion, the pulmonary artery pressures were labile with fluctuations. A customized fenestration was made in a 16 mm muscular ventricular septal defect occluder (MVSO with a 4.5 mm bare-metal coronary stent. The pulmonary artery pressures remained at half of the aortic pressures after the procedure. This fenestration model precisely and predictably fenestrated a large occluder device used to close a hypertensive large PDA. Long-term patency of these fenestrations has to be assessed on the follow-up, and may be improved through larger fenestrations, systemic anticoagulation and use of covered stents.

  3. The Use of ExoSeal Vascular Closure Device for Direct Antegrade Superficial Femoral Artery Puncture Site Hemostasis

    Energy Technology Data Exchange (ETDEWEB)

    Rimon, Uri, E-mail: rimonu@sheba.health.gov.il; Khaitovich, Boris, E-mail: borislena@012.net.il [Tel-Aviv University, Diagnostic and Interventional Imaging Department, Chaim Sheba Medical Center, Tel-Hashomer, Affiliated to the Sackler School of Medicine (Israel); Yakubovich, Dmitry, E-mail: Dmitry.Yakubovitch@sheba.health.gov.il [Tel-Aviv University, Vascular Surgery Department, Chaim Sheba Medical Center, Tel-Hashomer, Affiliated to the Sackler School of Medicine (Israel); Bensaid, Paul, E-mail: paulbensaid@hotmail.com; Golan, Gil, E-mail: gilgolan201@gmail.com [Tel-Aviv University, Diagnostic and Interventional Imaging Department, Chaim Sheba Medical Center, Tel-Hashomer, Affiliated to the Sackler School of Medicine (Israel); Silverberg, Daniel, E-mail: Daniel.Silverberg@sheba.health.gov.il [Tel-Aviv University, Vascular Surgery Department, Chaim Sheba Medical Center, Tel-Hashomer, Affiliated to the Sackler School of Medicine (Israel)

    2015-06-15

    PurposeThis study was designed to assess the efficacy and safety of the ExoSeal vascular closure device (VCD) to achieve hemostasis in antegrade access of the superficial femoral artery (SFA).MethodsWe retrospectively reviewed the outcome of ExoSeal VCD used for hemostasis in 110 accesses to the SFA in 93 patients between July 2011 and July 2013. All patients had patent proximal SFA based on computer tomography angiography or ultrasound duplex. Arterial calcifications at puncture site were graded using fluoroscopy. The SFA was accessed in an antegrade fashion with ultrasound or fluoroscopic guidance. In all patients, 5–7F vascular sheaths were used. The ExoSeal VCD was applied to achieve hemostasis at the end of the procedure. All patients were clinically examined and had ultrasound duplex exam for any puncture site complications during the 24 h postprocedure.ResultsIn all procedures, the ExoSeal was applied successfully. We did not encounter any device-related technical failure. There were four major complications in four patients (3.6 %): three pseudoaneurysms, which were treated with direct thrombin injection, and one hematoma, which necessitated transfusion of two blood units. All patients with complications were treated with anticoagulation preprocedure or received thrombolytic therapy.ConclusionsThe ExoSeal VCD can be safely used for antegrade puncture of the SFA, with a high procedural success rate (100 %) and a low rate of access site complications (3.6 %)

  4. Efficacy of bronchoscopic closure of a bronchopleural fistula with amplatzer devices: long-term follow-up.

    Science.gov (United States)

    Fruchter, Oren; El Raouf, Bayya Abed; Abdel-Rahman, Nader; Saute, Milton; Bruckheimer, Elchanan; Kramer, Mordechai R

    2014-01-01

    The development of a bronchopleural fistula (BPF) is associated with high rates of morbidity and mortality. We have developed a minimally invasive method of bronchoscopic BPF closure using Amplatzer devices (AD) and Amplatzer vascular plugs (AVP), with excellent short-term results. The aim of the present report was to explore the long-term outcome of patients treated by Amplatzer occluders and the durability of this novel modality of BPF treatment. A total of 31 central BPF in 31 patients (mean age 66.8 years, range 19-91) were sealed under moderate sedation bronchoscopically by either AD (n = 19) or AVP (n = 12). The average follow-up period was 17.6 months (range 1-68 months). The main etiology for BPF was surgery (n = 24), pneumonectomy (n = 14) or lobectomy/segmentectomy (n = 10). The underlying disease was either primary (n = 19) or metastatic (n = 2) lung cancer. The immediate success rate was 96% as symptoms related to BPF disappeared in 30 of the 31 patients. Short-term (<30 days) mortality was 13% (4 patients). At follow-up, 14 patients (45%) are still alive. Out of 12 patients with late mortality, in 5 patients (41%) the death was directly related to cancer relapse, and no patient died due to BPF recurrence. Endobronchial closure of BPF using both types of Amplatzer occluders (AD and AVP) is a minimally invasive effective modality of treatment with high safety profile and satisfactory long-term outcome considering the poor prognosis in this particular group of patients. © 2013 S. Karger AG, Basel.

  5. Efficacy and Safety of Augmenting the Preclose Technique with a Collagen-Based Closure Device for Percutaneous Endovascular Aneurysm Repair

    Energy Technology Data Exchange (ETDEWEB)

    Patel, Rafiuddin, E-mail: rafiuddin.patel@ouh.nhs.uk [Oxford University Hospitals NHS Trust, Department of Radiology, John Radcliffe Hospital (United Kingdom); Juszczak, Maciej T. [Oxford University Hospitals NHS Trust, Department of Vascular Surgery, John Radcliffe Hospital (United Kingdom); Bratby, Mark J. [Oxford University Hospitals NHS Trust, Department of Radiology, John Radcliffe Hospital (United Kingdom); Sideso, Ediri [Oxford University Hospitals NHS Trust, Department of Vascular Surgery, John Radcliffe Hospital (United Kingdom); Anthony, Susan; Tapping, Charles R. [Oxford University Hospitals NHS Trust, Department of Radiology, John Radcliffe Hospital (United Kingdom); Handa, Ashok; Darby, Christopher R.; Perkins, Jeremy [Oxford University Hospitals NHS Trust, Department of Vascular Surgery, John Radcliffe Hospital (United Kingdom); Uberoi, Raman [Oxford University Hospitals NHS Trust, Department of Radiology, John Radcliffe Hospital (United Kingdom)

    2015-08-15

    PurposeTo report our experience of selectively augmenting the preclose technique for percutaneous endovascular aneurysm repair (p-EVAR) with an Angio-Seal device as a haemostatic adjunct in cases of significant bleeding after tensioning the sutures of the suture-mediated closure devices.Materials and MethodsProspectively collected data for p-EVAR patients at our institute were analysed. Outcomes included technical success and access site complications. A logistic regression model was used to analyse the effects of sheath size, CFA features and stent graft type on primary failure of the preclose technique necessitating augmentation and also on the development of complications.Resultsp-EVAR was attempted via 122 CFA access sites with a median sheath size of 18-French (range 12- to 28-French). Primary success of the preclose technique was 75.4 % (92/122). Angio-Seal augmentation was utilised as an adjunct to the preclose technique in 20.5 % (25/122). The overall p-EVAR success rate was 95.1 % (116/122). There was a statistically significant relationship (p = 0.0093) between depth of CFA and primary failure of preclose technique. CFA diameter, calcification, type of stent graft and sheath size did not have significant effects on primary preclose technique failure. Overall 4.9 % (6/122) required surgical conversion but otherwise there were no major complications.ConclusionAugmentation with an Angio-Seal device is a safe and effective adjunct to increase the success rate of the preclose technique in p-EVAR.

  6. Network Meta-analysis of Randomized Trials on the Safety of Vascular Closure Devices for Femoral Arterial Puncture Site Haemostasis.

    Science.gov (United States)

    Jiang, Jun; Zou, Junjie; Ma, Hao; Jiao, Yuanyong; Yang, Hongyu; Zhang, Xiwei; Miao, Yi

    2015-09-08

    The safety of vascular closure devices (VCDs) is still debated. The emergence of more related randomized controlled trials (RCTs) and newer VCDs makes it necessary to further evaluate the safety of VCDs. Relevant RCTs were identified by searching PubMed, EMBASE, Google Scholar and the Cochrane Central Register of Controlled Trials electronic databases updated in December 2014. Traditional and network meta-analyses were conducted to evaluate the rate of combined adverse vascular events (CAVEs) and haematomas by calculating the risk ratios and 95% confidence intervals. Forty RCTs including 16868 patients were included. Traditional meta-analysis demonstrated that there was no significant difference in the rate of CAVEs between all the VCDs and manual compression (MC). Subgroup analysis showed that FemoSeal and VCDs reported after the year 2005 reduced CAVEs. Moreover, the use of VCDs reduced the risk of haematomas compared with MC. Network meta-analysis showed that AngioSeal, which might be the best VCD among all the included VCDs, was associated with reduced rates of both CAVE and haematomas compared with MC. In conclusion, the use of VCDs is associated with a decreased risk of haematomas, and FemoSeal and AngioSeal appears to be better than MC for reducing the rate of CAVEs.

  7. Morphologic features of puncture sites after exoseal vascular closure device implantation: Changes on follow-up computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Ryu, Hwa Seong; Jang, Joo Yeon; Kim, Tae Un; Lee, Jun Woo; Park, Jung Hwan; Choo, Ki Seok; Cho, Mong; Yoon, Ki Tae; Hong, Young Ki; Jeon, Ung Bae [Pusan National University Yangsan Hospital, Yangsan (Korea, Republic of)

    2017-05-15

    The study aimed to evaluate the morphologic changes in transarterial chemoembolization (TACE) puncture sites implanted with an ExoSeal vascular closure device (VCD) using follow-up computed tomography (CT). 16 patients who used ExoSeal VCD after TACE were enrolled. Using CT images, the diameters and anterior wall thicknesses of the puncture sites in the common femoral artery (CFA) were compared with those of the contralateral CFA before TACE, at 1 month after every TACE session, and at the final follow-up period. The rates of complications were also evaluated. There were no puncture- or VCD-related complications. Follow-up CT images of the CFA's of patients who used ExoSeal VCDs showed eccentric vascular wall thickening with soft-tissue densities considered to be hemostatic plugs. Final follow-up CT images (mean, 616 days; range, 95–1106 days) revealed partial or complete resorption of the hemostatic plugs. The CFA puncture site diameters did not differ statistically from those of the contralateral CFA on the final follow-up CT (p > 0.05), regardless of the number of VCDs used. Follow-up CT images of patients who used ExoSeal VCDs showed no significant vascular stenosis or significant vessel wall thickening.

  8. MRI after implantation of a novel femoral closure device following intra-arterial catheterisation: implications for subsequent contrast-enhanced MR angiography.

    Science.gov (United States)

    Mohrs, Oliver K; Petersen, Steffen E; Nowak, Bernd; Kauczor, Hans-Ulrich; Voigtlaender, Thomas

    2010-05-01

    To assess MRI safety aspects and artefacts of a novel femoral artery closure device during contrast-enhanced MR angiography in patients following intra-arterial catheterisation. Ten consecutive patients underwent MRI within 24 h of coronary angiography and placement of a femoral artery closure device. We used a T2-weighted gradient-echo MRI sequence to measure the device-related artefact size in comparison with a phantom image, phase-contrast flow measurement proximal to, at the level of and distal to the device to quantify potential differences in flow velocity and contrast-enhanced 3D gradient-echo MR angiography to differentiate potential femoral artery stenosis from device-related artefacts. The mean size of the oval-shaped artefact was 8.4 x 6.6 mm (+/-1.0 x 0.8 mm) and was almost identical to the maximum artefact size of the phantom measurement (8.3 x 5.7 mm). Device placement did not result in an increased peak velocity (proximal 69 +/- 23 cm/s, at the level of 64 +/- 11 cm/s and distal to the device 63 +/- 12 cm/s, p = 0.67). The mean artefact penetration into the vessel lumen was 0.5 +/- 0.5 mm (percentage vessel narrowing 7.0 +/- 6%; range 0-16%). The MR conditional StarClose femoral artery closure device was used safely within 24 h of deployment at 1.5 T. Despite clip-related artefacts MR angiography will allow for easy differentiation of clip-related artefacts from high-grade atherosclerotic stenosis.

  9. MRI after implantation of a novel femoral closure device following intra-arterial catheterisation: implications for subsequent contrast-enhanced MR angiography

    Energy Technology Data Exchange (ETDEWEB)

    Mohrs, Oliver K. [University of Heidelberg, Department of Diagnostic and Interventional Radiology, Heidelberg (Germany); Darmstadt Radiology, Department of Cardiovascular Imaging at Alice-Hospital, Darmstadt (Germany); Petersen, Steffen E. [The London Chest Hospital, William Harvey Research Institute, Centre Lead for Advanced Cardiovascular Imaging, London (United Kingdom); Nowak, Bernd; Voigtlaender, Thomas [Cardiovascular Center Bethanien (CCB), Frankfurt/Main (Germany); Kauczor, Hans-Ulrich [University of Heidelberg, Department of Diagnostic and Interventional Radiology, Heidelberg (Germany)

    2010-05-15

    To assess MRI safety aspects and artefacts of a novel femoral artery closure device during contrast-enhanced MR angiography in patients following intra-arterial catheterisation. Ten consecutive patients underwent MRI within 24 h of coronary angiography and placement of a femoral artery closure device. We used a T2-weighted gradient-echo MRI sequence to measure the device-related artefact size in comparison with a phantom image, phase-contrast flow measurement proximal to, at the level of and distal to the device to quantify potential differences in flow velocity and contrast-enhanced 3D gradient-echo MR angiography to differentiate potential femoral artery stenosis from device-related artefacts. The mean size of the oval-shaped artefact was 8.4 x 6.6 mm ({+-}1.0 x 0.8 mm) and was almost identical to the maximum artefact size of the phantom measurement (8.3 x 5.7 mm). Device placement did not result in an increased peak velocity (proximal 69 {+-} 23 cm/s, at the level of 64 {+-} 11 cm/s and distal to the device 63 {+-} 12 cm/s, p = 0.67). The mean artefact penetration into the vessel lumen was 0.5 {+-} 0.5 mm (percentage vessel narrowing 7.0 {+-} 6%; range 0-16%). The MR conditional StarClose femoral artery closure device was used safely within 24 h of deployment at 1.5 T. Despite clip-related artefacts MR angiography will allow for easy differentiation of clip-related artefacts from high-grade atherosclerotic stenosis. (orig.)

  10. Incomplete left atrial appendage occlusion and thrombus formation after Watchman implantation treated with anticoagulation followed by further transcatheter closure with a second-generation Amplatzer Cardiac Plug (Amulet device).

    Science.gov (United States)

    Lam, Simon Cheung Chi; Bertog, Stefan; Sievert, Horst

    2015-02-01

    We report a case of incomplete left atrial appendage (LAA) closure after Watchman device (Atritech, Boston Scientific, Natrick, MA) implantation which subsequently developed a thrombus 3 years after the initial procedure. The thrombus resolved after a short period of anticoagulation with warfarin, and the LAA was successfully occluded with a second-generation Amplatzer Cardiac Plug (Amulet device, AGA, St Jude Medical, Minneapolis, MN). Incomplete LAA closure may be associated with increased risk of thrombus formation and further closure with a second device after a course of anticoagulation may be a reasonable and feasible strategy. © 2014 Wiley Periodicals, Inc. © 2014 Wiley Periodicals, Inc.

  11. A minimally invasive technique for closing an iatrogenic subclavian artery cannulation using the Angio-Seal closure device: two case reports

    OpenAIRE

    2012-01-01

    Abstract Introduction In the two cases described here, the subclavian artery was inadvertently cannulated during unsuccessful access to the internal jugular vein. The puncture was successfully closed using a closure device based on a collagen plug (Angio-Seal, St Jude Medical, St Paul, MN, USA). This technique is relatively simple and inexpensive. It can provide clinicians, such as intensive care physicians and anesthesiologists, with a safe and straightforward alternative to major surgery an...

  12. Day-case peripheral angioplasty using nurse-led admission, discharge, and follow-up procedures: arterial closure devices are not necessary

    Energy Technology Data Exchange (ETDEWEB)

    Kasthuri, R.; Karunaratne, D.; Andrew, H.; Sumner, J. [Department of Radiology, Manchester Royal Infirmary, Oxford Road, Manchester M13 9WL (United Kingdom); Chalmers, N. [Department of Radiology, Manchester Royal Infirmary, Oxford Road, Manchester M13 9WL (United Kingdom)], E-mail: nicholas.chalmers@cmmc.nhs.uk

    2007-12-15

    Aim: To audit the safety of day-case peripheral arterial intervention without the use of arterial-closure devices using nurse-led admission, discharge, and follow-up procedures. Materials and methods: Patients referred for elective, peripheral vascular intervention were selected for day-case care according to pre-determined criteria using telephone triage. Post-procedure haemostasis was achieved using manual compression. After 3 h bed-rest, patients were mobilized and discharged at 5 h. Patients were contacted by telephone next working day to audit complications. Results: One hundred and eighty-three elective day-case peripheral interventions were performed over 2 years, predominantly using 6 F sheaths. No closure devices were used. Five patients (2%) returned to the department because of persistent groin symptoms the next day. One of these had a false aneurysm. Four required no further treatment. A single patient returned at day 6 with a delayed false aneurysm. Conclusion: Day-case peripheral vascular intervention can be safely performed in appropriately selected patients without the use of arterial closure devices. Specialist radiology nurses have a major role in the counselling, care, and follow-up of these patients.

  13. Intermediate- and long-term follow-up of device closure of patent arterial duct with severe pulmonary hypertension: factors predicting outcome.

    Science.gov (United States)

    Sadiq, Masood; Rehman, Asif U; Hyder, Najam; Qureshi, Ahmad U; Kazmi, Tehmina; Qureshi, Shakeel A

    2017-01-01

    In patients with large patent arterial ducts and severe pulmonary hypertension, the natural history of progression of pulmonary hypertension is very variable. Whether to close or not to close is often a difficult decision, as there are no established haemodynamic parameters predicting reversibility. The objectives of this study were to evaluate the results of device closure of large patent arterial ducts with severe pulmonary hypertension after 2 years of age and to determine haemodynamic variables associated with its regression during long-term follow-up. A total of 45 patients, with median age of 10 (2-27) years, with large patent arterial ducts and severe pulmonary hypertension, were considered. Haemodynamic variables were assessed in air, oxygen, and after occlusion. The follow-up was performed to assess regression of pulmonary hypertension. Device closure was successful in 43 (96%) patients. Pulmonary artery systolic and mean pressures decreased from 79 to 67 mmHg and from 59 to 50 mmHg, respectively (p25% (both in oxygen) (p=0.007). Device closure of large patent arterial ducts with severe pulmonary hypertension is safe and effective. Pulmonary vascular resistance index and systolic and mean pulmonary artery pressures in oxygen are the key prognostic variables predicting regression of pulmonary hypertension.

  14. Primary limited lumbar discectomy with an annulus closure device: one-year clinical and radiographic results from a prospective, multi-center study.

    Science.gov (United States)

    Lequin, Michiel B; Barth, Martin; Thomė, Claudius; Bouma, Gerrit J

    2012-12-01

    Discectomy as a treatment for herniated lumbar discs results in outcomes after surgery that are not uniformly positive. Surgeons face the dilemma between limited nucleus removal which is associated with a higher risk of recurrence, or more aggressive nucleus removal which may lead to disc height loss and persistent back-pain. annulus closure devices may allow for the benefits of limited nucleus removal without the increased risk of recurrence. This is an interim report of an ongoing 24-month post-marketing study of the Barricaid® annulus closure device, consisting of a flexible polymer mesh that blocks the defect, held in place by a titanium bone anchor. We prospectively enrolled 45 patients at four hospitals, and implanted the Barricaid® after a limited discectomy. annulus defect size and volume of removed nucleus were recorded. Reherniations were reported, pain and function were monitored and imaging was performed at regular intervals during 24 months of follow-up. At 12 months postsurgery, pain and function were significantly improved, comparing favorably to reported results from limited discectomy. Disc height has been well maintained. One reherniation has occurred (2.4%), which was associated with a misplaced device. No device fracture, subsidence or migration has been observed. The use of an annulus closure device may provide a reduction in reherniation rate for lumbar discectomy patients with large annulus defects who are at the greatest risk of recurrence. Using such a device should provide the surgeon increased confidence in minimizing nucleus removal, which, in turn, may preserve disc height and biomechanics, reducing degeneration and associated poor clinical outcomes in the long-term. A randomized multicenter study evaluating limited discectomy with and without the Barricaid® is currently underway, and will provide a higher level of evidence.

  15. The New 3D Printed Left Atrial Appendage Closure with a Novel Holdfast Device: A Pre-Clinical Feasibility Animal Study.

    Directory of Open Access Journals (Sweden)

    M Brzeziński

    Full Text Available Many patients undergoing cardiac surgery have risk factors for both atrial fibrillation (AF and stroke. The left atrial appendage (LAA is the primary site for thrombi formation. The most severe complication of emboli derived from LAA is stroke, which is associated with a 12-month mortality rate of 38% and a 12-month recurrence rate of 17%. The most common form of treatment for atrial fibrillation and stroke prevention is the pharmacological therapy with anticoagulants. Nonetheless this form of therapy is associated with high risk of major bleeding. Therefore LAA occlusion devices should be tested for their ability to reduce future cerebral ischemic events in patients with high-risk of haemorrhage.The aim of this study was to evaluate the safety and feasibility of a novel left atrial appendage exclusion device with a minimally invasive introducer in a swine model.A completely novel LAA device, which is composed of two tubes connected together using a specially created bail, was designed using finite element modelling (FEM to obtain an optimal support force of 36 N at the closure line. The monolithic form of the occluder was obtained by using additive manufacturing of granular PA2200 powder with the technology of selective laser sintering (SLS. Fifteen swine were included in the feasibility tests, with 10 animals undergoing fourteen days of follow-up and 5 animals undergoing long-term observation of 3 months. For one animal, the follow-up was further prolonged to 6 months. The device was placed via minithoracotomy. After the observation period, all of the animals were euthanized, and their hearts were tested for LAA closure and local inflammatory and tissue response.After the defined observation period, all fifteen hearts were explanted. In all cases the full closure of the LAA was achieved. The macroscopic and microscopic evaluation of the explanted hearts showed that all devices were securely integrated in the surrounding tissues. No

  16. The Impact of Turtle Excluder Devices and Fisheries Closures on Loggerhead and Kemp's Ridley Strandings in the Western Gulf of Mexico

    Science.gov (United States)

    Lewison, R.L.; Crowder, L.B.; Shaver, D.J.

    2003-01-01

    The Sea Turtle Stranding and Salvage Network has been monitoring turtle strandings for more than 20 years in the United States. High numbers of strandings in the early to mid-1980s prompted regulations to require turtle excluder devices (TEDs) on shrimping vessels (trawlers). Following year-round TED implementation in 1991, however, stranding levels in the Gulf of Mexico increased. We evaluated the efficacy of TEDs and other management actions (e.g., fisheries closures) on loggerhead (Caretta caretta) and Kemp's ridley (Lepidochelys kempii) turtle populations by analyzing a long-term, stranding data set from the western Gulf of Mexico. Our analyses suggest that both sea turtle population growth and shrimping activity have contributed to the observed increase in strandings. Compliance with regulations requiring turtle excluder devices was a significant factor in accounting for annual stranding variability: low compliance was correlated with high levels of strandings. Our projections suggest that improved compliance with TED regulations will reduce strandings to levels that, in conjunction with other protective measures, should promote population recoveries for loggerhead and Kemp's ridley turtles. Local, seasonal fisheries closures, concurrent with TED enforcement, could reduce strandings to even lower levels. A seasonal closure adjacent to a recently established Kemp's ridley nesting beach may also reduce mortality of nesting adults and thus promote long-term population persistence by fostering the establishment of a robust secondary nesting site.

  17. Endovascular Repair Using Suture-Mediated Closure Devices and Balloon Tamponade following Inadvertent Subclavian Artery Catheterization with Large-Caliber Hemodialysis Catheter.

    Science.gov (United States)

    Park, Taek Kyu; Yang, Jeong Hoon; Choi, Seung-Hyuk

    2016-07-01

    Accidental subclavian artery cannulation is an uncommon but potentially serious complication of central venous catheterization. Removal of a catheter inadvertently placed in the subclavian artery can lead to substantial bleeding, as achieving hemostasis in this area through manual compression presents considerable difficulty. Additionally, surgical treatment might be unsuitable for high-risk patients due to comorbidities. Here, we report a case of an inadvertently-inserted 11.5-French hemodialysis catheter in the subclavian artery during internal jugular venous catheterization. We performed percutaneous closure of the subclavian artery using three 6-French Perclose Proglide® devices with a balloon tamponade in the proximal part of the subclavian artery. Closure was completed without embolic neurological complications.

  18. Management of pleural empyema with a vacuum-assisted closure device and reconstruction of open thoracic window in a patient with liver cirrhosis.

    Science.gov (United States)

    Munguía-Canales, Daniel Alejandro; Vargas-Mendoza, Gary Kosai; Alvarez-Bestoff, Gustavo; Calderón-Abbo, Moisés Cutiel

    2013-10-01

    The patient is a 21-year-old female, diagnosed with cryptogenic cirrhosis at the age of 9. She presented with left post-pneumonic empyema that did not remit with conventional medical management and evolved with fistulization to the skin in the 7th intercostal space in the left subscapular region. We performed an open thoracic window procedure, and on the 6th day the patient was sent home with a portable vacuum-assisted closure device, with changes of the material every 4 days until the cavity was completed obliterated (92 days). Imaging tests showed full expansion of the lung, and chest wall reconstruction was performed with titanium rods. The high mortality of empyema in patients with liver disease requires both implementing and searching for new adjuvant therapies, like the use of vacuum-assisted closure systems and reconstruction with titanium rods. Controlled studies with a wide range of cases are needed for proper evaluation.

  19. Suitability of a 7-F ExoSeal Vascular Closure Device for Femoral Artery Punctures Made by 8-F or 9-F Introducer Sheaths.

    Science.gov (United States)

    Goto, Shunsaku; Ohshima, Tomotaka; Ishikawa, Kojiro; Yamamoto, Taiki; Nishizawa, Toshihisa; Shimato, Shinji; Kato, Kyozo

    2017-08-01

    To establish the safety and efficacy of the 7-F ExoSeal device for the closure of femoral puncture sites made by 8-F or 9-F introducer sheaths. Between January 2013 and December 2016, 332 patients (mean age 68.4±12.1 years; 195 men) underwent neurointerventional procedures via percutaneous puncture of the common femoral artery and an 8-F (n=272, 81.9%) or 9-F (n=60, 18.1%) introducer. The access sites were sealed with a 7-F ExoSeal in all cases. Procedure success and closure-related complication rates were evaluated, and risk factors for complications were analyzed by comparing patient characteristics between those who did and did not experience complications. Procedure success rates were 99.3% in the 8-F group and 100% in the 9-F group. The overall complication rate was 6.3% (n=17; all in the 8-F group), of which 13 (4.8%) were minor sequelae, including access-site hematoma (n=8), oozing (n=3), pseudoaneurysm (n=1), and retroperitoneal bleeding (n=1). Among the 4 (1.5%) major complications were 3 instances of bleeding requiring a blood transfusion and 1 surgical vascular repair. No complications were observed in the 9-F group. Patients who experienced complications had significantly longer activated clotting times (262±46 vs 218±55 seconds; pF ExoSeal vascular closure device is safe and effective for the closure of femoral puncture sites made by 8-F or 9-F introducer sheaths.

  20. A minimally invasive technique for closing an iatrogenic subclavian artery cannulation using the Angio-Seal closure device: two case reports

    Directory of Open Access Journals (Sweden)

    Szkup Peter L

    2012-03-01

    Full Text Available Abstract Introduction In the two cases described here, the subclavian artery was inadvertently cannulated during unsuccessful access to the internal jugular vein. The puncture was successfully closed using a closure device based on a collagen plug (Angio-Seal, St Jude Medical, St Paul, MN, USA. This technique is relatively simple and inexpensive. It can provide clinicians, such as intensive care physicians and anesthesiologists, with a safe and straightforward alternative to major surgery and can be a life-saving procedure. Case presentation In the first case, an anesthetist attempted ultrasound-guided access to the right internal jugular vein during the preoperative preparation of a 66-year-old Caucasian man. A 7-French (Fr triple-lumen catheter was inadvertently placed into his arterial system. In the second case, an emergency physician inadvertently placed a 7-Fr catheter into the subclavian artery of a 77-year-old Caucasian woman whilst attempting access to her right internal jugular vein. Both arterial punctures were successfully closed by means of a percutaneous closure device (Angio-Seal. No complications were observed. Conclusions Inadvertent subclavian arterial puncture can be successfully managed with no adverse clinical sequelae by using a percutaneous vascular closure device. This minimally invasive technique may be an option for patients with non-compressible arterial punctures. This report demonstrates two practical points that may help clinicians in decision-making during daily practice. First, it provides a practical solution to a well-known vascular complication. Second, it emphasizes a role for proper vascular ultrasound training for the non-radiologist.

  1. Reversal of severe mitral regurgitation by device closure of a large patent ductus arteriosus in a premature infant.

    Science.gov (United States)

    Kheiwa, Ahmed; Ross, Robert D; Kobayashi, Daisuke

    2017-01-01

    We report a critically ill premature infant with severe mitral valve regurgitation associated with pulmonary hypertension and a severely dilated left atrium from a large patent ductus arteriosus. The mitral valve regurgitation improved significantly with normalisation of left atrial size 4 weeks after percutaneous closure of the patent ductus arteriosus. This case highlights the potential reversibility of severe mitral valve regurgitation with treatment of an underlying cardiac shunt.

  2. Efficacy and Safety of a Novel Vascular Closure Device (Glubran 2 Seal) After Diagnostic and Interventional Angiography in Patients with Peripheral Arterial Occlusive Disease

    Energy Technology Data Exchange (ETDEWEB)

    Del Corso, Andrea [University of Pisa, Department of Vascular Surgery (Italy); Bargellini, Irene, E-mail: irenebargellini@hotmail.com; Cicorelli, Antonio; Perrone, Orsola [University of Pisa, Department of Diagnostic and Interventional Radiology (Italy); Leo, Michele [University of Pisa, Department of Vascular Surgery (Italy); Lunardi, Alessandro [University of Pisa, Department of Diagnostic and Interventional Radiology (Italy); Alberti, Aldo; Tomei, Francesca [University of Pisa, Department of Vascular Surgery (Italy); Cioni, Roberto [University of Pisa, Department of Diagnostic and Interventional Radiology (Italy); Ferrari, Mauro [University of Pisa, Department of Vascular Surgery (Italy); Bartolozzi, Carlo [University of Pisa, Department of Diagnostic and Interventional Radiology (Italy)

    2013-04-15

    To prospectively evaluate safety and efficacy of a novel vascular closure device (Glubran 2 Seal) after peripheral angiography in patients with peripheral arterial occlusive disease (PAOD). From December 2010 to June 2011, all consecutive patients with PAOD undergoing peripheral angiography were prospectively enrolled onto the study after percutaneous antegrade or retrograde puncture of the common femoral artery. After angiography, the Glubran 2 Seal device was used to achieve hemostasis. The following data were registered: technical success and manual compression duration, patients' discomfort (scale 0-5), operators' technical difficulty (scale 0-5), and vascular complications. The site of hemostasis was evaluated by clinical inspection and color-coded Duplex ultrasound performed 1 day and 1 month after the procedure. One hundred seventy-eight patients were enrolled (112 male, mean age 70.8 years) with a total of 206 puncture sites, including 104 (50.5 %) antegrade accesses. The device was successful in 198(96.1 %) of 206 procedures, with 8 cases of manual compression lasting longer than 5 min (maximum 20 min). No major vascular complications were observed, resulting in 100 % procedural success. Minor complications occurred in seven procedures (3.4 %), including two cases of pseudoaneurysms, successfully treated by ultrasound-guided glue injection. The mean {+-} standard deviation score for patients' discomfort was 0.9 {+-} 0.7, whereas the mean score for operators' difficulty was 1.2 {+-} 0.9. In patients with PAOD, the Glubran 2 Seal represents a simple, painless, and efficient vascular closure device, able to achieve hemostasis both in antegrade and retrograde accesses.

  3. Percutaneous Steerable Robotic Tool Delivery Platform and Metal MEMS Device for Tissue Manipulation and Approximation: Closure of Patent Foramen Ovale in an Animal Model

    Science.gov (United States)

    Vasilyev, Nikolay V.; Gosline, Andrew H.; Butler, Evan; Lang, Nora; Codd, Patrick J.; Yamauchi, Haruo; Feins, Eric N.; Folk, Chris R.; Cohen, Adam L.; Chen, Richard; Zurakowski, David; del Nido, Pedro J.; Dupont, Pierre E

    2013-01-01

    Background Beating-heart image-guided intracardiac interventions have been evolving rapidly. To extend the domain of catheter-based and transcardiac interventions into reconstructive surgery, a new robotic tool delivery platform (TDP) and tissue approximation device have been developed. Initial results employing these tools to perform patent foramen ovale (PFO) closure are described. Methods and Results A robotic TDP comprised of superelastic metal tubes provides the capability of delivering and manipulating tools and devices inside the beating heart. A new device technology is also presented that utilizes a metal-based MicroElectroMechanical Systems (MEMS) manufacturing process to produce fully-assembled and fully-functional millimeter-scale tools. As a demonstration of both technologies, a PFO creation and closure was performed in a swine model. In the first group of animals (N=10), a preliminary study was performed. The procedural technique was validated with a transcardiac handheld delivery platform and epicardial echocardiography, video-assisted cardioscopy and fluoroscopy. In the second group (N=9), the procedure was performed percutaneously using the robotic TDP under epicardial echocardiography and fluoroscopy imaging. All PFO’s were completely closed in the first group. In the second group, the PFO was not successfully created in 1 animal, and the defects were completely closed in 6 of the 8 remaining animals. Conclusions In contrast to existing robotic catheter technologies, the robotic TDP utilizes a combination of stiffness and active steerability along its length to provide the positioning accuracy and force application capability necessary for tissue manipulation. In combination with a MEMS tool technology, it can enable reconstructive procedures inside the beating heart. PMID:23899870

  4. Safety and effectiveness of a circumferential clip-based vascular closure device for hemostasis in off-label applications: Comparison with standard applications

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Seung Chan; Kim, Chang Won [Dept. of Radiology, Pusan National University School of Medicine, Pusan National University Hospital, Busan (Korea, Republic of); Jeon, Ung Bae [Dept. of Radiology, Pusan National University School of Medicine, Yangsan Pusan National University Hospital, Yangsan (Korea, Republic of)

    2016-09-15

    We investigated the efficacy and safety of a circumferential nitinol clip based arterial closure device following arteriotomy, especially in off-label applications. Consecutive patients who underwent the procedure with arteriotomy from January 2011 to February 2014 were included in this study. We defined standard use as the use of StarClose for retrograde puncture of the common femoral artery (CFA) and off-label use as the use of StarClose for retrograde puncture of the superficial femoral artery (SFA), antegrade puncture of the CFA or SFA, puncture of the brachial artery or puncture of the vascular graft. The procedures performed included percutaneous transluminal angioplasty and thrombolysis. Technical success was defined as complete hemostasis achieved within 3 minute after the closure. Complications, and laboratory findings associated with coagulation function, were also investigated. There were 146 cases of standard applications and 111 cases of off-label applications. Technical success was achieved in all cases. The off-label group comprised the use of StarClose for retrograde puncture of the SFA (n = 19), antegrade puncture of the CFA or SFA (n = 74), brachial artery puncture (n = 5), larger sheath than 6 Fr (n = 7) and vascular graft puncture (n = 6). Minor complications were noted in both groups (standard group: 7.5%, off-label group: 2.7%). Off-label use of StarClose is safe and feasible.

  5. Transcatheter closure of atrial septal defect protects from pulmonary edema: septal occluder device gradually reduces LR shunt.

    Science.gov (United States)

    Murakami, Tsutomu; Nakazawa, Gaku; Horinouchi, Hitomi; Torii, Sho; Ijichi, Takeshi; Ohno, Yohei; Amino, Mari; Shinozaki, Norihiko; Ogata, Nobuhiko; Yoshimachi, Fuminobu; Yoshioka, Koichiro; Ikari, Yuji

    2017-01-01

    A 56-year-old woman was diagnosed as atrial septal defect (ASD) with pulmonary hypertension; pulmonary blood flow/systemic blood flow (Qp/Qs) of 2.3, pulmonary artery pressure (PAP) of 71/23(39) mmHg and diastolic dysfunction of left ventricle. PAP was improved after medical therapy; therefore, transcatheter ASD closure was performed. Seven days later, left-sided heart failure occurred, however, the improvement of Qp/Qs (1.7) and PAP of 51/21(32) was confirmed. Diuretic therapy was introduced which led to further decrease of PAP 40/12(25) and Qp/Qs (1.1). Because of gradual decrease of Qp/Qs, this patient appeared to be protected from acute pulmonary edema.

  6. Performance Assessment of Bi-Directional Knotless Tissue-Closure Devices in Juvenile Chinook Salmon Surgically Implanted with Acoustic Transmitters, 2009 - Final Report

    Energy Technology Data Exchange (ETDEWEB)

    Woodley, Christa M.; Wagner, Katie A.; Bryson, Amanda J.

    2012-11-09

    The purpose of this report is to assess the performance of bi-directional knotless tissue-closure devices for use in tagging juvenile salmon. This study is part of an ongoing effort at Pacific Northwest National Laboratory (PNNL) to reduce unwanted effects of tags and tagging procedures on the survival and behavior of juvenile salmonids, by assessing and refining suturing techniques, suture materials, and tag burdens. The objective of this study was to compare the performance of the knotless (barbed) suture, using three different suture patterns (treatments: 6-point, Wide “N”, Wide “N” Knot), to the current method of suturing (MonocrylTM monofilament, discontinuous sutures with a 2×2×2×2 knot) used in monitoring and research programs with a novel antiseptic barrier on the wound (“Second Skin”).

  7. Device closure of secundum atrial septal defect in a 4.5 kilogram infant: Novel use of the Amplatzer DuctOccluder II device.

    Science.gov (United States)

    McCrossan, B A; Walsh, K P

    2016-02-01

    Modest secundum atrial septal defects (2°ASD) may cause significant pulmonary over perfusion during infancy, particularly in conjunction with left heart obstructive lesions. Amplatzer Septal Occluders are not ideal in this setting especially given recent concerns regarding device erosion. We report the first use of the Amplatzer Duct Occluder II device (ADO2) to close a 2°ASD in a 4.5 kg infant.

  8. Feasibility and Safety of Vascular Closure Devices in an Antegrade Approach to Either the Common Femoral Artery or the Superficial Femoral Artery

    Energy Technology Data Exchange (ETDEWEB)

    Gutzeit, Andreas, E-mail: andreas.gutzeit@ksw.ch; Schie, Bram van, E-mail: Bram.vanschie@hotmail.com; Schoch, Eric, E-mail: eric.schoch@ksw.ch [Cantonal Hospital Winterthur, Department of Radiology (Switzerland); Hergan, Klaus, E-mail: k.hergan@salk.at [Paracelsus Medical University Salzburg, Department of Radiology (Austria); Graf, Nicole, E-mail: graf@biostatistics.ch; Binkert, Christoph A., E-mail: christoph.binkert@ksw.ch [Cantonal Hospital Winterthur, Department of Radiology (Switzerland)

    2012-10-15

    Introduction: The purpose of the present study was to analyze complications following antegrade puncture of the common femoral artery (CFA) and the superficial femoral artery (SFA) using vascular closure systems (VCS). Methods: A single-center, retrospective study was performed after obtaining approval from the institutional review board and informed consent from all patients. At our center, the CFA or SFA are used for arterial access. All patients were evaluated clinically on the same day. If there was any suspicion of an access site problem, Duplex ultrasound was performed. Results: Access location was the CFA in 50 patients and the SFA in 130 patients. The sheath size ranged from 4F to 10F. Two patients had to be excluded because of lack of follow-up. Successful hemostasis was achieved in 162 of 178 cases (91 %). The following complications were observed in 16 patients (8.9 %): 4 pseudoaneurysms (2.2 %), 11 hematomas (6.2 %), and 1 vascular occlusion (0.5 %). The two pseudoaneurysms healed spontaneously, in one case an ultrasound-guided thrombin injection was performed, and one aneurysm was compressed manually. No further medical therapy was needed for the hematomas. The one vascular occlusion was treated immediately with angioplasty using a contralateral approach. No significant difference was noted between the CFA and the SFA group with respect to complications (p = 1.000). Conclusions: The use of closure devices for an antegrade approach up to 10F is feasible and safe. No differences in low complication rates were observed between CFA and SFA.

  9. Transcatheter closure of a patent ductus arteriosus in an elderly patient with the Gianturco-Grifka vascular occlusion device.

    Science.gov (United States)

    Befeler, B; Justiniano, A; Zahn, E

    2000-10-01

    This paper reports the unusual case of a 76-year-old woman who was discovered to have a hemodynamically significant patent ductus arteriosus following uneventful mitral valve replacement, utilizing cardiopulmonary bypass. The shunt was successfully eliminated using a new transcatheter device, thereby obviating the need for further surgery. The patient did not have calcification within the ductus, making diagnosis prior to surgery more difficult.

  10. Use of vacuum-assisted closure device in a disastrous form of abdominal sepsis and stoma site infection: systematic review and report of a case.

    Science.gov (United States)

    Popović, Milos; Barisić, Goran; Marković, Velimir; Petrović, Jelena; Krivokapić, Zoran

    2012-01-01

    Use of Vacuum-Assisted Closure (VAC) for treatment of open abdomen has been established predominantly in cases of severe abdominal trauma, resulting with high percentage of primary fascial closure. The role of VAC technique in cases of severe diffuse peritonitis is not definitely incorrigible. However, in cases of severe complicated abdominal sepsis VAC come up as a last resort.

  11. Pulmonary edema following transcatheter closure of atrial septal defect

    Directory of Open Access Journals (Sweden)

    Singhi Anil

    2010-01-01

    Full Text Available Pulmonary edema after device closure of atrial septal defect (ASD is a rare complication. We present illustrative images of a case of pulmonary edema after device closure of ASD in a 53 year old adult. Older patients undergoing ASD closure can benefit from their left atrial and left ventricular end diastolic pressures measurement before and after temporary balloon occlusion of ASD.

  12. Analysis of Alfvén eigenmode destabilization by energetic particles in Large Helical Device using a Landau-closure model

    Science.gov (United States)

    Varela, J.; Spong, D. A.; Garcia, L.

    2017-04-01

    Energetic particle populations in nuclear fusion experiments can destabilize the Alfvén Eigenmodes through inverse Landau damping and couplings with gap modes in the shear Alfvén continua. We use the reduced MHD equations to describe the linear evolution of the poloidal flux and the toroidal component of the vorticity in a full 3D system, coupled with equations of density and parallel velocity moments for the energetic particles. We add the Landau damping and resonant destabilization effects using a closure relation. We apply the model to study the Alfvén mode stability in the inward-shifted configurations of the Large Helical Device (LHD), performing a parametric analysis of the energetic particle β ({βf} ) in a range of realistic values, the ratios of the energetic particle thermal/Alfvén velocities ({{V}\\text{th}}/{{V}A0} ), the magnetic Lundquist numbers (S) and the toroidal modes (n). The n  =  1 and n  =  2 TAEs are destabilized, although the n  =  3 and n  =  4 TAEs are weakly perturbed. The most unstable configurations are associated with the density gradients of energetic particles in the plasma core: the TAEs are destabilized, even for small energetic particle populations, if their thermal velocity is lower than 0.4 times the Alfvén velocity. The frequency range of MHD bursts measured in the LHD are 50–70 kHz for the n  =  1 and 60–80 kHz for the n  =  2 TAE, which is consistent with the model predictions. ).

  13. Pelvic flexure enterotomy closure in the horse with a TA-90 stapling device: a retrospective clinical study of 84 cases (2001-2008).

    Science.gov (United States)

    Rosser, Julie; Brounts, Sabrina; Slone, Don; Lynch, Tim; Livesey, Michael; Hughes, Faith; Clark, Carol

    2012-06-01

    Our objective was to compare survival and complication rates of horses undergoing pelvic flexure enterotomy closure with a TA-90 stapler to those with hand-sewn closure. Medical records of horses undergoing pelvic flexure enterotomy between 2001 and 2008 were reviewed. History, clinical signs, surgical findings, surgical techniques, and post-operative complications were recorded. Long-term outcome was established by telephone questionnaire. Of 84 pelvic flexure enterotomies performed, 70 were stapled and 14 were hand-sewn. Seventy-seven horses survived to discharge (91.7%). There were no significant associations between survival and closure technique (P = 0.69). Follow-up was available for 54 horses; 50 survived long-term (93.0%). No statistical significance was identified between long-term survival and closure method (P = 0.39). Forty horses went on to athletic performance (80.0%). TA-90 stapled closure of pelvic flexure enterotomies is a safe technique resulting in survival and complication rates equivalent to those of hand-sewn closure.

  14. Restaurant closures

    CERN Multimedia

    Novae Restauration

    2012-01-01

    Christmas Restaurant closures Please note that the Restaurant 1 and Restaurant 3 will be closed from Friday, 21 December at 5 p.m. to Sunday, 6 January, inclusive. They will reopen on Monday, 7 January 2013.   Restaurant 2 closure for renovation To meet greater demand and to modernize its infrastructure, Restaurant 2 will be closed from Monday, 17 December. On Monday, 14 January 2013, Sophie Vuetaz’s team will welcome you to a renovated self-service area on the 1st floor. The selections on the ground floor will also be expanded to include pasta and pizza, as well as snacks to eat in or take away. To ensure a continuity of service, we suggest you take your break at Restaurant 1 or Restaurant 3 (Prévessin).

  15. Application value of echocardiography in perventricular device closure of ventricular septal defect%超声心动图在微创外科室间隔缺损封堵治疗中的应用价值

    Institute of Scientific and Technical Information of China (English)

    康彧; 唐红; 白文娟; 安琪; 赁可; 宋海波

    2011-01-01

    目的 探讨超声心动图在微创外科室间隔缺损(VSD)封堵治疗中的应用价值.方法 经胸超声心动图(TTE)筛选拟行微创外科VSD封堵治疗患者169例,术中经食管超声心动图(TEE)再次评估,对具备封堵条件者进行实时引导和监控.术后3~5 d及3、6、12个月 TTE随访.结果 术中TEE评估对15例不适宜封堵者直接改行VSD修补术.行微创封堵术154例,成功137例,成功率88.9%;封堵失败改行VSD修补术17例.术中即刻观察10例有微量残余分流,3例主动脉瓣有微量反流,7例三尖瓣反流较术前减轻或消失,11例三尖瓣出现少量反流.术后TTE随访封堵器无移位,4例残余分流消失,1例三尖瓣反流较术前略有加重,左心室重构改善.结论 超声心动图在微创外科VSD封堵的术前诊断、术中监控及术后效果评价中均发挥了重要作用.%Objective To explore the application value of echocardiography in perventricular device closure of ventricular septal defect ( VSD ). Methods One hundred and sixty - nine patients with VSD were selected by transthoracic echocardiography ( TTE ) and prepared to receive off pump surgical treatment-perventricular device closure. All the patients were re-evaluated in cardiac surgical procedures by transesophageal echocardiography ( TEE ). The patients suitable to the perventricular device closure were guided and observed. After operation, 3 ~5d,3,6,12 months follow-up were performed by TTE. Results Fifteen cases were not suitable to the device closure by intraoperative TEE re-evaluation and were directly repaired under cardiopulmonary bypass. 137 of 154 cases treated with perventricular device closure were succeeded( 137/154, 88.9% ), 17 cases were failed and received the repair surgery. TEE was performed immediately after occluder release. The tricuspid regurgitation was decreased or disappeared in 7 patients, while the closure caused new mild tricuspid regurgitation in 11 patients, and there were 10

  16. Safety and efficacy of device closure for patent foramen ovale for secondary prevention of neurological events: Comprehensive systematic review and meta-analysis of randomized controlled trials

    Energy Technology Data Exchange (ETDEWEB)

    Hakeem, Abdul [University of Arkansas for Medical Sciences, Little Rock, AR (United States); Marmagkiolis, Konstantinos [Citizens Memorial Hospital Heart and Vascular Institute, Bolivar, MO (United States); Hacioglu, Yalcin; Uretsky, Barry F.; Gundogdu, Betul [University of Arkansas for Medical Sciences, Little Rock, AR (United States); Leesar, Massoud [University of Alabama at Birmingham, Birmingham, AL (United States); Bailey, Steven R. [University of Texas Health Sciences Center at San Antonio, San Antonio, TX (United States); Cilingiroglu, Mehmet, E-mail: mcilingiroglu@yahoo.com [Arkansas Heart Hospital, Little Rock, AR (United States)

    2013-11-15

    Background: Controversy persists regarding the management of patients with cryptogenic stroke and patent foramen ovale (PFO). We performed a meta-analysis of randomized controlled trials comparing PFO closure with medical therapy. Methods and Results: A prospective protocol was developed and registered using the following data sources: PubMed, Cochrane Register of Controlled Trials, conference proceedings, and Internet-based resources of clinical trials. Primary analyses were performed using the intention-to-treat method. Three randomized trials comparing percutaneous PFO closure vs. medical therapy for secondary prevention of embolic neurological events formed the data set. Baseline characteristics were similar. During long-term follow-up, the pooled incidence of the primary endpoint (composite of stroke, death, or fatal stroke) was 3.4% in the PFO closure arm and 4.8% in the medical therapy group [risk-reduction (RR) 0.7 (0.48–1.06); p = 0.09]. The incidence of recurrent neurological events (secondary endpoint) was 1.7% for PFO closure and 2.7% for medical therapy [RR 0.66 (0.35–1.24), p = 0.19]. There was no difference in terms of death or adverse events between the two groups. Conclusions: While this meta-analysis of randomized clinical trials demonstrated no statistical significance in comparison to medical therapy, there was a trend towards overall improvement in outcomes in the PFO closure group.

  17. Design of closure works

    NARCIS (Netherlands)

    Verhagen, H.J.

    2007-01-01

    This chapter discusses the design aspects of estuary and river closures and those of reservoir dams and certain other hydraulic structures. The focus of this chapter is on closures, not on the situation after the closure has been completed.

  18. Echocardiographic assessment and percutaneous closure of multiple atrial septal defects

    Directory of Open Access Journals (Sweden)

    Timperley Jonathan

    2004-07-01

    Full Text Available Abstract Atrial septal defect closure is now routinely performed using a percutaneous approach under echocardiographic guidance. Centrally located, secundum defects are ideal for device closure but there is considerable morphological variation in size and location of the defects. A small proportion of atrial septal defects may have multiple fenestrations and these are often considered unsuitable for device closure. We report three cases of multiple atrial septal defects successfully closed with two Amplatzer septal occluders.

  19. Closure Issues with Families.

    Science.gov (United States)

    Craig, Steven E.; Bischof, Gary H.

    Closure of the counseling relationship constitutes both an ending and a beginning. Although closure signifies the ending of the present counseling relationship, many family counselors conceptualize closure as the start of a working relationship between counselor and family that may be summoned in future times of crisis or during a difficult life…

  20. Technical note: subclavian artery misplacement of a 12F Shaldon catheter: percutaneous repair with a local closure device under temporary balloon tamponade; Technische Mitteilung: Entfernung eines fehlplatzierten 12F Shaldon Katheters aus der A. subclavia und Abdichtung mittels Verschlusssystem bei temporaerer Ballonblockade

    Energy Technology Data Exchange (ETDEWEB)

    Wildberger, J.E.; Katoh, M.; Guenther, R.W. [Klinik fuer Radiologische Diagnostik, RWTH Aachen (Germany); Fussen, R. [Anaesthesiologische Klinik, Medizinisches Zentrum Kreis Aachen GmbH (Germany)

    2006-06-15

    A case of subsequent percutaneous repair using a local closure device with a collagen block (VasoSeal {sup registered}) and temporary balloon tamponade after inadvertent subclavian artery misplacement of a 12F Shaldon catheter is reported. Balloon occlusion safely prevented displacement of collagen into the vascular lumen by occluding the 12F entry site. Furthermore, collagen-induced coagulation was facilitated. (orig.)

  1. Closure The Definitive Guide

    CERN Document Server

    Bolin, Michael

    2010-01-01

    If you're ready to use Closure to build rich web applications with JavaScript, this hands-on guide has precisely what you need to learn this suite of tools in depth. Closure makes it easy for experienced JavaScript developers to write and maintain large and complex codebases -- as Google has demonstrated by using Closure with Gmail, Google Docs, and Google Maps. Author and Closure contributor Michael Bolin has included numerous code examples and best practices, as well as valuable information not available publicly until now. You'll learn all about Closure's Library, Compiler, Templates, tes

  2. The influence of deficient retro-aortic rim on technical success and early adverse events following device closure of secundum atrial septal defects: An Analysis of the IMPACT Registry(®).

    Science.gov (United States)

    O'Byrne, Michael L; Gillespie, Matthew J; Kennedy, Kevin F; Dori, Yoav; Rome, Jonathan J; Glatz, Andrew C

    2017-01-01

    Concern regarding aortic erosion has focused attention on the retro-aortic rim in patients undergoing device closure of atrial septal defects (ASD), but its effect on early outcomes is not well studied. A multicenter retrospective cohort study of patients undergoing device occlusion of ASD between 1/2011-10/2014 was performed, using data from the IMproving Pediatric and Adult Congenital Treatment Registry. Subjects were divided between those with retro-aortic rim technical failure and major early adverse events. Case times were measured as surrogates of technical complexity. The effect of deficient retro-aortic rim on primary outcomes was assessed using hierarchical logistic regression, adjusting for other suspected covariates and assessing whether they represent independent risk factors RESULTS: 1,564 subjects (from 77 centers) were included, with deficient retro-aortic rim present in 40%. Technical failure occurred in 91 subjects (5.8%) and a major early adverse event in 64 subjects (4.1%). Adjusting for known covariates, the presence of a deficient retro-aortic rim was not significantly associated with technical failure (OR: 1.3, 95% CI: 0.9-2.1) or major early adverse event (OR: 0.7, 95% CI: 0.4-1. 2). Total case (P = 0.01) and fluoroscopy time (P = 0.02) were greater in subjects with deficient rim, but sheath time was not significantly different (P = 0.07). Additional covariates independently associated with these outcomes were identified. Deficient retro-aortic rim was highly prevalent but not associated with increased risk of technical failure or early adverse events. Studies with longer follow-up are necessary to assess other outcomes, including device erosion. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  3. Transcatheter closure of patent ductus arteriosus: past, present and future.

    Science.gov (United States)

    Baruteau, Alban-Elouen; Hascoët, Sébastien; Baruteau, Julien; Boudjemline, Younes; Lambert, Virginie; Angel, Claude-Yves; Belli, Emre; Petit, Jérôme; Pass, Robert

    2014-02-01

    This review aims to describe the past history, present techniques and future directions in transcatheter treatment of patent ductus arteriosus (PDA). Transcatheter PDA closure is the standard of care in most cases and PDA closure is indicated in any patient with signs of left ventricular volume overload due to a ductus. In cases of left-to-right PDA with severe pulmonary arterial hypertension, closure may be performed under specific conditions. The management of clinically silent or very tiny PDAs remains highly controversial. Techniques have evolved and the transcatheter approach to PDA closure is now feasible and safe with current devices. Coils and the Amplatzer Duct Occluder are used most frequently for PDA closure worldwide, with a high occlusion rate and few complications. Transcatheter PDA closure in preterm or low-bodyweight infants remains a highly challenging procedure and further device and catheter design development is indicated before transcatheter closure is the treatment of choice in this delicate patient population. The evolution of transcatheter PDA closure from just 40 years ago with 18F sheaths to device delivery via a 3F sheath is remarkable and it is anticipated that further improvements will result in better safety and efficacy of transcatheter PDA closure techniques.

  4. Closure Operators and Closure Systems on Quantaloid-Enriched Categories

    Institute of Scientific and Technical Information of China (English)

    Min LIU; Bin ZHAO

    2013-01-01

    In this paper,we introduce the fundamental notions of closure operator and closure system in the framework of quantaloid-enriched category.We mainly discuss the relationship between closure operators and adjunctions and establish the one-to-one correspondence between closure operators and closure systems on quantaloid-enriched categories.

  5. Transcatheter closure with double Amplatzer septal occluder device in treatment of multiple atrial septal defects%双封堵器介入治疗多孔性房间隔缺损

    Institute of Scientific and Technical Information of China (English)

    孙鑫; 杨延坤; 郑宏; 徐争鸣; 徐仲英; 蒋世良; 赵世华; 张戈军; 吴文辉

    2013-01-01

    Objective To evaluate the clinical feasibility and effectiveness of transcatheter closure of multiple atrial septal defects (ASD) using double occluders.Methods Seventeen patients underwent transcatheter closure of multiple ASD (2 or 3) with double devices under X-ray fluoroscopy and TTE.Electrocardiogram,X-ray chest radiography as well as echocardigraphy were performed to evaluate the effectiveness after the procedure.Results All patients had multiple ASD (12 with 2 defects and 5 with 3 defects).TTE during the procedures showed that the mean diameters of the larger,medium and smaller defects was (13.94±3.21)mm,(9.65±2.64)mm and (4.80±1.92)mm,respectively.Tanscatheter closure of multiple ASD succeeded in 16 patiets (16/17,94.12 %),1 failed because the second defect was not suitable for intervention,and was cured by surgery,and totally 32 occluder devices were implanted and closed 37 defects.The mean diameters of the larger and the smaller occluders was (20.75 ± 4.07)mm and (16.94 ± 3.75)mm,respectively,larger than the value showed by TTE during procedures by (7.06±2.65)mm (larger defects) and (7.44±3.25)mm (medium defects).Immediately after the procedure,3 patients had trivial shunt (2 patients with 3 defects),which disappeared 2,3 days and 3 month later,respectively.No severe complication occurred,while femoral arteriovenous fistula was observed in 1 patient and disappeared 1 month later.The cardiothoracic ratio of X-ray chest radiography and the right ventricle internal diameter measured by echocardiography dropped during follow-up (all P<0.01).Conclusion Transcatheter closure of multiple ASD with double devices is feasible,safe and effective.%目的 对双封堵器介入治疗多孔性房间隔缺损(ASD)的可行性与有效性进行临床评估.方法 对17例多孔性ASD(12例为2孔,5例为3孔)患者在X线透视和超声心动图监测下植入Amplatzer封堵器,同时闭合2~3个缺损.术后复查ECG、X线平

  6. Eyelid closure at death

    Directory of Open Access Journals (Sweden)

    A D Macleod

    2009-01-01

    Full Text Available Aim: To observe the incidence of full or partial eyelid closure at death. Materials and Methods: The presence of ptosis was recorded in 100 consecutive hospice patient deaths. Results: Majority (63% of the patients died with their eyes fully closed, however, 37% had bilateral ptosis at death, with incomplete eye closure. In this study, central nervous system tumor involvement and/or acute hepatic encephalopathy appeared to be pre-mortem risk factors of bilateral ptosis at death. Conclusion: Organicity and not psychogenicity is, therefore, the likely etiology of failure of full eyelid closure at death.

  7. Incomplete RV Remodeling After Transcatheter ASD Closure in Pediatric Age.

    Science.gov (United States)

    Agha, Hala M; El-Saiedi, Sonia A; Shaltout, Mohamed F; Hamza, Hala S; Nassar, Hayat H; Abdel-Aziz, Doaa M; Tantawy, Amira Esmat El

    2015-10-01

    Published data showing the intermediate effect of transcatheter device closure of atrial septal defect (ASD) in the pediatric age-group are scarce. The objective of the study was to assess the effects of transcatheter ASD closure on right and left ventricular functions by tissue Doppler imaging (TDI). The study included 37 consecutive patients diagnosed as ASD secundum by transthoracic echocardiography and TEE and referred for transcatheter closure at Cairo University Specialized Pediatric Hospital, Egypt, from October 2010 to July 2013. Thirty-seven age- and sex-matched controls were selected. TDI was obtained using the pulsed Doppler mode, interrogating the right cardiac border (the tricuspid annulus) and lateral mitral annulus, and myocardial performance index (MPI) was calculated at 1-, 3-, 6- and 12-month post-device closure. Transcatheter closure of ASD and echocardiographic examinations were successfully performed in all patients. There were no significant differences between two groups as regards the age, gender, weight or BSA. TDI showed that patients with ASD had significantly prolonged isovolumetric contraction, relaxation time and MPI compared with control group. Decreased tissue Doppler velocities of RV and LV began at one-month post-closure compared with the controls. Improvement in RVMPI and LVMPI began at 1-month post-closure, but they are still prolonged till 1 year. Reverse remodeling of right and left ventricles began 1 month after transcatheter ASD closure, but did not completely normalize even after 1 year of follow-up by tissue Doppler imaging.

  8. 33 CFR 155.805 - Closure devices.

    Science.gov (United States)

    2010-07-01

    ... which is not connected for the transfer of oil or hazardous material must be blanked off with butterfly valves, wafer-type resilient seated valves, blank flanges, or other means acceptable to the COTP or...

  9. The myth of closure.

    Science.gov (United States)

    Boss, Pauline; Carnes, Donna

    2012-12-01

    Therapies for grief and loss have traditionally focused on the work of grieving. The goal was to reach an endpoint, now popularly called closure. There are, however, many people who, through no fault of their own, find a loss so unclear that there can be no end to grief. They have not failed in the work of grieving, but rather have suffered ambiguous loss, a type of loss that is inherently open ended. Instead of closure, the therapeutic goal is to help people find meaning despite the lack of definitive information and finality. Hope lies in increasing a family's tolerance for ambiguity, but first, professionals must increase their own comfort with unanswered questions. In this article, the authors, one a poet, the other a family therapist and theorist, offer a unique blending of theory, reflection, and poetry to experientially deepen the process of self-reflection about a kind of loss that defies closure. © FPI, Inc.

  10. Achieving closure at Fernald

    Energy Technology Data Exchange (ETDEWEB)

    Bradburne, John; Patton, Tisha C.

    2001-02-25

    When Fluor Fernald took over the management of the Fernald Environmental Management Project in 1992, the estimated closure date of the site was more than 25 years into the future. Fluor Fernald, in conjunction with DOE-Fernald, introduced the Accelerated Cleanup Plan, which was designed to substantially shorten that schedule and save taxpayers more than $3 billion. The management of Fluor Fernald believes there are three fundamental concerns that must be addressed by any contractor hoping to achieve closure of a site within the DOE complex. They are relationship management, resource management and contract management. Relationship management refers to the interaction between the site and local residents, regulators, union leadership, the workforce at large, the media, and any other interested stakeholder groups. Resource management is of course related to the effective administration of the site knowledge base and the skills of the workforce, the attraction and retention of qualified a nd competent technical personnel, and the best recognition and use of appropriate new technologies. Perhaps most importantly, resource management must also include a plan for survival in a flat-funding environment. Lastly, creative and disciplined contract management will be essential to effecting the closure of any DOE site. Fluor Fernald, together with DOE-Fernald, is breaking new ground in the closure arena, and ''business as usual'' has become a thing of the past. How Fluor Fernald has managed its work at the site over the last eight years, and how it will manage the new site closure contract in the future, will be an integral part of achieving successful closure at Fernald.

  11. Tank closure reducing grout

    Energy Technology Data Exchange (ETDEWEB)

    Caldwell, T.B.

    1997-04-18

    A reducing grout has been developed for closing high level waste tanks at the Savannah River Site in Aiken, South Carolina. The grout has a low redox potential, which minimizes the mobility of Sr{sup 90}, the radionuclide with the highest dose potential after closure. The grout also has a high pH which reduces the solubility of the plutonium isotopes. The grout has a high compressive strength and low permeability, which enhances its ability to limit the migration of contaminants after closure. The grout was designed and tested by Construction Technology Laboratories, Inc. Placement methods were developed by the Savannah River Site personnel.

  12. Coblation-assisted closure of persistent tracheocutaneous fistulae.

    Science.gov (United States)

    Walner, David L; Mularczyk, Chris; Kakodkar, Kedar

    2016-06-01

    Persistent tracheocutaneous fistulae (PTCFs) are sequelae of long-term tracheostomy tube use, and while many procedures exist to correct this issue, several are invasive and incur risk to the patient. This case study discusses a minimally invasive approach to closure of small PFTFs with a coblator device that may reduce the risks associated with other closure procedures. We demonstrated successful tracheocutaneous fistulae closure after coblation in all 4 patients that the operation was performed. We believe this technique can be considered for patients under select circumstances and can be part of a surgeon's armamentarium for the treatment of small PTCFs.

  13. History of Sandia National Laboratories` auxiliary closure mechanisms

    Energy Technology Data Exchange (ETDEWEB)

    Weydert, J.C. [Sandia National Labs., Albuquerque, NM (United States); Ponder, G.M. [Geo-Centers, Inc., Albuquerque, NM (United States)

    1993-12-01

    An essential component of a horizontal, underground nuclear test setup at the Nevada Test Site is the auxiliary closure system. The massive gates that slam shut immediately after a device has been detonated allow the prompt radiation to pass, but block debris and hot gases from continuing down the tunnel. Thus, the gates protect experiments located in the horizontal line-of-sight steel pipe. Sandia National Laboratories has been the major designer and developer of these closure systems. This report records the history of SNL`s participation in and contributions to the technology of auxiliary closure systems used in horizontal tunnel tests in the underground test program.

  14. Mail Office annual closure

    CERN Multimedia

    2013-01-01

    On the occasion of the annual closure of CERN, there will be no mail distributed on Friday 20 December 2013 but mail will be collected in the morning. Nevertheless, you will still be able to bring your outgoing mail to Building 555-R-002 until 12 noon.  

  15. MNC Subsidiary Closure

    DEFF Research Database (Denmark)

    de Faria, Pedro; Preto, Miguel Torres; Sofka, Wolfgang

    2013-01-01

    We investigate the consequences of MNC subsidiary closures for employees who lose their jobs. We ask to what degree the foreign knowledge that they were exposed to is valued in their new job. We argue theoretically that this foreign knowledge is both valuable and not readily available in the host...

  16. MNC Subsidiary Closure

    DEFF Research Database (Denmark)

    de Faria, Pedro; Sofka, Wolfgang; Torres Preto, Miguel

    We investigate the consequences of MNC subsidiary closures for employees who lose their jobs. We ask to what degree the foreign knowledge that they were exposed to is valued in their new job. We argue theoretically that this foreign knowledge is both valuable and not readily available in the host...

  17. Ring closure in actin polymers

    Science.gov (United States)

    Sinha, Supurna; Chattopadhyay, Sebanti

    2017-03-01

    We present an analysis for the ring closure probability of semiflexible polymers within the pure bend Worm Like Chain (WLC) model. The ring closure probability predicted from our analysis can be tested against fluorescent actin cyclization experiments. We also discuss the effect of ring closure on bend angle fluctuations in actin polymers.

  18. A case against closure

    Directory of Open Access Journals (Sweden)

    Olin, Doris

    2005-01-01

    Full Text Available Este artigo examina a objeção ao fechamento [dedutivo] que surge no contexto de certos paradoxos epistêmicos, paradoxos cuja conclusão é que a crença justificada pode ser inconsistente. É universalmente aceito que, se essa conclusão é correta, o fechamento deve ser rejeitado, para que se evite a crença justificada em enunciados contraditórios (P, ~P. Mas, mesmo que os argumentos desses paradoxos - o paradoxo da falibilidade (do prefácio e o paradoxo da loteria - seja mal sucedidos, eles, ainda assim, sugerem a existência de evidência independente para uma objeção mais direta contra o fechamento. O exame do argumento da falibilidade revela uma exigência de modéstia epistêmica que viola o fechamento a partir de múltiplas premissas. A reflexão sobre o paradoxo da loteria nos confronta com um dilema em que cada alternativa fornece um contra-exemplo ao fechamento a partir de uma única premissa. Seja ou não possível a inconsistência racional, há uma objeção contra o fechamento. This paper examines the case against closure that arises in the context of certain epistemic paradoxes, paradoxes whose conclusion is that it is possible for justified belief to be inconsistent. It is generally agreed that if this conclusion is correct, closure must be rejected in order to avoid justified belief in contradictory statements (P, ~P. But even if the arguments of these paradoxes – the fallibility (preface paradox and the lottery paradox – are unsuccessful, they nonetheless suggest independent grounds for a more direct case against closure. Examination of the fallibility argument reveals a requirement of epistemic modesty that violates multiple premise closure. Reflection on the lottery paradox presents us with a dilemma in which each alternative provides a counterexample to single premise closure. Whether or not rational inconsistency is possible, there is a case against closure.

  19. Summer season | Cafeteria closures

    CERN Multimedia

    2013-01-01

    Please note the following cafeteria closures over the summer season: Bldg. 54 closed from 29/07/2013 to 06/09/2013. Bldg. 13: closed from 13/07/2013 to 06/09/2013. Restaurant No. 2, table service (brasserie and restaurant): closed from 01/08/2013 to 06/09/2013. Bldg. 864: closed from 29/07/2013 to 06/09/2013. Bldg. 865: closed from 29/07/2013 to 06/09/2013.

  20. Summer season | Cafeteria closures

    CERN Multimedia

    2013-01-01

    Please note the following cafeteria closures over the summer season: Bldg. 54 closed from 29/07/2013 to 06/09/2013. Bldg. 13: closed from 13/07/2013 to 06/09/2013. Restaurant No. 2, table service (brasserie and restaurant): closed from 01/08/2013 to 06/09/2013. Bldg. 864: closed from 29/07/2013 to 06/09/2013. Bldg. 865: closed from 29/07/2013 to 06/09/2013.

  1. RELAP-7 Closure Correlations

    Energy Technology Data Exchange (ETDEWEB)

    Zou, Ling [Idaho National Lab. (INL), Idaho Falls, ID (United States); Berry, R. A. [Idaho National Lab. (INL), Idaho Falls, ID (United States); Martineau, R. C. [Idaho National Lab. (INL), Idaho Falls, ID (United States); Andrs, D. [Idaho National Lab. (INL), Idaho Falls, ID (United States); Zhang, H. [Idaho National Lab. (INL), Idaho Falls, ID (United States); Hansel, J. E. [Idaho National Lab. (INL), Idaho Falls, ID (United States); Sharpe, J. P. [Idaho National Lab. (INL), Idaho Falls, ID (United States); Johns, Russell C. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-04-01

    The RELAP-7 code is the next generation nuclear reactor system safety analysis code being developed at the Idaho National Laboratory (INL). The code is based on the INL’s modern scientific software development framework, MOOSE (Multi-Physics Object Oriented Simulation Environment). The overall design goal of RELAP-7 is to take advantage of the previous thirty years of advancements in computer architecture, software design, numerical integration methods, and physical models. The end result will be a reactor systems analysis capability that retains and improves upon RELAP5’s and TRACE’s capabilities and extends their analysis capabilities for all reactor system simulation scenarios. The RELAP-7 code utilizes the well-posed 7-equation two-phase flow model for compressible two-phase flow. Closure models used in the TRACE code has been reviewed and selected to reflect the progress made during the past decades and provide a basis for the colure correlations implemented in the RELAP-7 code. This document provides a summary on the closure correlations that are currently implemented in the RELAP-7 code. The closure correlations include sub-grid models that describe interactions between the fluids and the flow channel, and interactions between the two phases.

  2. A case of hybrid closure of a muscular ventricular septal defect: anatomical complexity and surgical management.

    Science.gov (United States)

    Karimi, Mohsen; Hulsebus, Elise; Murdison, Kenneth; Wiles, Henry

    2012-06-01

    Complex muscular ventricular septal defect poses difficult surgical management and is associated with high morbidity and mortality despite advancements in surgical therapy. Device closure of muscular ventricular septal defect has been encouraging and has been used in hybrid approach at a few centres. However, device closure has some limitations in patients with complex muscular ventricular septal defect. We report a case of perventricular device closure of a complex muscular ventricular septal defect in a beating heart with entrapped right ventricular disc and its surgical management.

  3. Live 3D image overlay for arterial duct closure with Amplatzer Duct Occluder II additional size.

    Science.gov (United States)

    Goreczny, Sebstian; Morgan, Gareth J; Dryzek, Pawel

    2016-03-01

    Despite several reports describing echocardiography for the guidance of ductal closure, two-dimensional angiography remains the mainstay imaging tool; three-dimensional rotational angiography has the potential to overcome some of the drawbacks of standard angiography, and reconstructed image overlay provides reliable guidance for device placement. We describe arterial duct closure solely from venous approach guided by live three-dimensional image overlay.

  4. PFO closuRE and CryptogenIc StrokE (PRECISE) registry

    DEFF Research Database (Denmark)

    Wöhrle, Jochen; Bertrand, Bernard; Søndergaard, Lars;

    2012-01-01

    The Premere™ PFO closure device has a special design for closure of patent foramen ovale (PFO) including a flexible distance and angulation between the right and left disc providing minimal septal distortion. The primary objective of the study was to determine the degree of risk for stroke...

  5. Patent Foramen Ovale Closure or Antiplatelet Therapy for Cryptogenic Stroke.

    Science.gov (United States)

    Søndergaard, Lars; Kasner, Scott E; Rhodes, John F; Andersen, Grethe; Iversen, Helle K; Nielsen-Kudsk, Jens E; Settergren, Magnus; Sjöstrand, Christina; Roine, Risto O; Hildick-Smith, David; Spence, J David; Thomassen, Lars

    2017-09-14

    The efficacy of closure of a patent foramen ovale (PFO) in the prevention of recurrent stroke after cryptogenic stroke is uncertain. We investigated the effect of PFO closure combined with antiplatelet therapy versus antiplatelet therapy alone on the risks of recurrent stroke and new brain infarctions. In this multinational trial involving patients with a PFO who had had a cryptogenic stroke, we randomly assigned patients, in a 2:1 ratio, to undergo PFO closure plus antiplatelet therapy (PFO closure group) or to receive antiplatelet therapy alone (antiplatelet-only group). Imaging of the brain was performed at the baseline screening and at 24 months. The coprimary end points were freedom from clinical evidence of ischemic stroke (reported here as the percentage of patients who had a recurrence of stroke) through at least 24 months after randomization and the 24-month incidence of new brain infarction, which was a composite of clinical ischemic stroke or silent brain infarction detected on imaging. We enrolled 664 patients (mean age, 45.2 years), of whom 81% had moderate or large interatrial shunts. During a median follow-up of 3.2 years, clinical ischemic stroke occurred in 6 of 441 patients (1.4%) in the PFO closure group and in 12 of 223 patients (5.4%) in the antiplatelet-only group (hazard ratio, 0.23; 95% confidence interval [CI], 0.09 to 0.62; P=0.002). The incidence of new brain infarctions was significantly lower in the PFO closure group than in the antiplatelet-only group (22 patients [5.7%] vs. 20 patients [11.3%]; relative risk, 0.51; 95% CI, 0.29 to 0.91; P=0.04), but the incidence of silent brain infarction did not differ significantly between the study groups (P=0.97). Serious adverse events occurred in 23.1% of the patients in the PFO closure group and in 27.8% of the patients in the antiplatelet-only group (P=0.22). Serious device-related adverse events occurred in 6 patients (1.4%) in the PFO closure group, and atrial fibrillation occurred in 29

  6. 40 CFR 265.280 - Closure and post-closure.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 25 2010-07-01 2010-07-01 false Closure and post-closure. 265.280 Section 265.280 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES... location, topography, and surrounding land use, with respect to the potential effects of pollutant...

  7. FINAL CLOSURE PLAN SURFACE IMPOUNDMENTS CLOSURE, SITE 300

    Energy Technology Data Exchange (ETDEWEB)

    Lane, J E; Scott, J E; Mathews, S E

    2004-09-29

    Lawrence Livermore National Laboratory of the University of California (LLNL) operates two Class II surface impoundments that store wastewater that is discharged from a number of buildings located on the Site 300 Facility (Site 300). The wastewater is the by-product of explosives processing. Reduction in the volume of water discharged from these buildings over the past several years has significantly reduced the wastewater storage needs. In addition, the impoundments were constructed in 1984, and the high-density polyethylene (HDPE) geomembrane liners are nearing the end of their service life. The purpose of this project is to clean close the surface impoundments and provide new wastewater storage using portable, above ground storage tanks at six locations. The tanks will be installed prior to closure of the impoundments and will include heaters for allowing evaporation during relatively cool weather. Golder Associates (Golder) has prepared this Final Closure Plan (Closure Plan) on behalf of LLNL to address construction associated with the clean closure of the impoundments. This Closure Plan complies with State Water Resources Control Board (SWRCB) Section 21400 of the California Code of Regulations Title 27 (27 CCR {section}21400). As required by these regulations and guidance, this Plan provides the following information: (1) A site characterization, including the site location, history, current operations, and geology and hydrogeology; (2) The regulatory requirements relevant to clean closure of the impoundments; (3) The closure procedures; and, (4) The procedures for validation and documentation of clean closure.

  8. TRANSCATHETER CLOSURE OF PATENT DUCTUS ARTERIOSUS

    Institute of Scientific and Technical Information of China (English)

    高伟; 周爱卿; 余志庆; 李奋; 王荣发; 黄美蓉

    2002-01-01

    Objective To explore the efficacy of transcatheter closure of patent ductus arteriosus (PDA) with detachable coil and Amplatzer duct occluder (ADO). Methods Transcatheter colsure of PDA was performed in 160 cases, aged 4.56±2.67 years, of whom 3 had residual shunt after surgical ligation, 2 had pulmomary stenosis (PS), 1 had coarctation of aorta (COA), 1 had right aortic arch, and 2 had atrial septal defect (ASD). Results Detachable coils (Duct Occlude pfm or Cook Inc) were successfully used in 51 patients with a smallest PDA diameter of 1.86±0.78mm. Amplatzer duct occluders were also successfully performed in other 109 with a moderate to large PDA diameter of 3.89±1.32mm, of whom 3 with PS or COA were performed balloon dilation firstly, and 2 with ASD were performed PDA occlusion firstly; 1 month to 4.8years follow-up coil or Amplatzer device closure of PDA showed that neither residual shunt nor any complication. Conclusion It is suggested that the detachable coil and Amplatzer duct occluder are simple and safe for the catheter closure from small to large sized PDA.

  9. Fatigue testing of three peristernal median sternotomy closure techniques

    Directory of Open Access Journals (Sweden)

    Griffin Lanny V

    2008-09-01

    Full Text Available Abstract Background Failure of a sternotomy closure because of closure system fatigue is a complication that may result in dehiscence and put the individual at risk for serious complications. The purpose of this study was to assess the fatigue performance of three peristernal median sternotomy closure techniques (figure-of-eight stainless-steel wires, figure-of-eight stainless-steel cables, or Pectofix Dynamic Sternal Fixation [DSF] stainless-steel plates in order to quantify the potential risk of fatigue failure of these devices when subject to cyclic loads in physiologically relevant loading directions. Study Design All tests were conducted on polyurethane foam sternal models. A cardiothoracic surgeon divided each sternal model longitudinally and repaired it with a closure device. Tests were performed using a materials testing system that applied cyclic loading in a uniaxial direction until the test model catastrophically broke or data run-out occurred. For each loading direction (lateral distraction and longitudinal shear, five trials of each closure technique were tested. Life data and location of device failure (if present were evaluated. Statistical analysis was performed using regression with life data allowed for correlation between life data and the various closure techniques to develop risk assessment curves for each device. Results The data show that the figure-of-eight stainless-steel cable and the DSF plate systems are considerably less likely to fail under both lateral distraction and longitudinal shear cyclic loading conditions as compared to the figure-of-eight stainless-steel wire system. Moreover, the figure-of-eight stainless-steel cable system is the most resistant to failure, particularly for high cycle counts. Conclusion This study in addition to Cohen and Griffin's earlier published biomechanical comparison of the ultimate strength of these same three closure techniques provide extensive experimental evidence regarding the

  10. Percutaneous closure of a very large left atrial appendage using the Amplatzer amulet.

    Science.gov (United States)

    Freixa, Xavier; Kwai Chan, Jason Leung; Tzikas, Apostolos; Garceau, Patrick; Basmadjian, Arsène; Ibrahim, Réda

    2013-10-01

    Although percutaneous left atrial appendage (LAA) closure is becoming a common procedure worldwide, there are still some anatomic limitations. The size of the LAA is one of the current limitations as the most popular devices do not allow the closure of very large LAAs. The new Amplatzer Cardiac Plug 2, also called "Amulet," has been redesigned not only to improve delivery and safety but also to allow the closure of larger LAAs. The present report describes the successful closure of a very large LAA using the Amulet.

  11. 31. Left ventricular dysfunction after patent ductus arteriosus (PDA closure

    Directory of Open Access Journals (Sweden)

    Rihab Agouba

    2015-10-01

    Conclusions: Depressed LV-SFx may occur after PDA closure with higher incidence after catheter PDA device occlusion. All of preterm babies had surgical PDA occlusion and none of them presented with depressed LV-SFx in the post-operative follow-up. Further prospective studies are needed to investigate these observations.

  12. Planning for integrated mine closure

    Energy Technology Data Exchange (ETDEWEB)

    Linda Starke (ed.)

    2008-07-01

    This document presents an Integrated Mine Closure Planning Toolkit for the mining and metals sector. The toolkit is intended to be used to promote a more disciplined approach to integrated closure planning and to increase the uniformity of good practices across the sector. The concepts apply equally well to both large and small companies. The document is not intended to be prescriptive; it provides a suite of tools that can be brought to bear in formulating well-considered decisions when planning for closure. It uses a risk and opportunity based process to guide the practitioner through the iterative process of preparing for planned closure. The first section, with head office and mine management personnel as the primary audience, describes the participants of effective closure planning. Sections 2 and 3 provide the frameworks for a conceptual closure plan and a detailed plan. The key audiences for these two sections are mine management and head office personnel, financial modellers and estimators, governments, academics and non-governmental organizations. The forth section addresses decommissioning and post closure planning, and Section 5 draws together the conclusions and outlines several unresolved issues. The five narrative sections are followed by Section 6 which outlines 13 tools, some of which are already available in earlier ICMM publications, member practices and other sector-affiliated publications. Others have been developed to cover identified gaps. These tools provide the practitioner with practical work processes, examples and contexts within which to apply closure planning discipline.

  13. Endobronchial closure of bronchopleural fistulas with Amplatzer vascular plug.

    Science.gov (United States)

    Fruchter, Oren; Bruckheimer, Elchanan; Raviv, Yael; Rosengarten, Dror; Saute, Milton; Kramer, Mordechai R

    2012-01-01

    Bronchopulmonary fistula (BPF) is a severe complication following lobectomy or pneumonectomy and is associated with a high rate of morbidity and mortality. We have developed a novel minimally invasive method of central BPF closure using Amplatzer vascular plug (AVP) device that was originally designed for the transcatheter closure of vascular structures in patients with small BPF. Patients with BPFs were treated under conscious sedation by bronchoscopic closure of BPFs using AVP. After locating the fistula using bronchography, the self-expanding nitinol made AVP occluder to be delivered under direct bronchoscopic guidance over a loader wire into the fistula followed by bronchography to assure correct device positioning and sealing of the BPF. Six AVPs were placed in five patients, four males and one female, with a mean age of 62.3 years (range: 51-82 years). The underlying disorders and etiologies for BPF development were lobectomy (two patients), pneumonectomy for lung cancer (one patient), lobectomy due to necrotizing pneumonia (one patient), and post-tracheostomy tracheo-pleural fistula (one patient). In all the patients, the bronchoscopic procedure was successful and symptoms related to BPF disappeared following closure by the AVP. The results were maintained over a median follow-up of 9 months (range: 5-34 months). Endobronchial closure using the AVP is a safe and effective method for treatment of small postoperative BPF. The ease of their implantation by bronchoscopy under conscious sedation adds this novel technique to the armatorium of minimally invasive modalities for the treatment of small BPF.

  14. Hybrid closure of atrial septal defect: A modified approach

    Directory of Open Access Journals (Sweden)

    Kshitij Sheth

    2015-01-01

    Full Text Available A 3.5-year-old girl underwent transcatheter closure of patent ductus arteriosus in early infancy during which time her secundum atrial septal defect (ASD was left alone. When she came for elective closure of ASD, she was found to have bilaterally blocked femoral veins. The defect was successfully closed with an Amplatzer septal occluder (ASO; St. Jude Medical, Plymouth, MN, USA using a hybrid approach via a sub-mammary mini-thoracotomy incision without using cardiopulmonary bypass. At the end of 1-year follow-up, the child is asymptomatic with device in a stable position without any residual shunt.

  15. Pulmonary edema following transcatheter closure of atrial septal defect

    Directory of Open Access Journals (Sweden)

    Keerthi Chigurupati

    2015-01-01

    Full Text Available We describe an incident of development of acute pulmonary edema after the device closure of a secundum atrial septal defect in a 52-year-old lady, which was treated with inotropes, diuretics and artificial ventilation. Possibility of acute left ventricular dysfunction should be considered after the defect closure in the middle-aged patients as the left ventricular compliance may be reduced due to increased elastic stiffness and diastolic dysfunction. Baseline left atrial pressure may be > 10 mmHg in these patients. Associated risk factors for the left ventricular dysfunction are a large Qp:Qs ratio, systemic hypertension, severe pulmonary hypertension and paroxysmal atrial fibrillation.

  16. Pulmonary edema following transcatheter closure of atrial septal defect

    Science.gov (United States)

    Chigurupati, Keerthi; Reshmi, Liza Jose; Gadhinglajkar, Shrinivas; Venkateshwaran, S.; Sreedhar, Rupa

    2015-01-01

    We describe an incident of development of acute pulmonary edema after the device closure of a secundum atrial septal defect in a 52-year-old lady, which was treated with inotropes, diuretics and artificial ventilation. Possibility of acute left ventricular dysfunction should be considered after the defect closure in the middle-aged patients as the left ventricular compliance may be reduced due to increased elastic stiffness and diastolic dysfunction. Baseline left atrial pressure may be > 10 mmHg in these patients. Associated risk factors for the left ventricular dysfunction are a large Qp:Qs ratio, systemic hypertension, severe pulmonary hypertension and paroxysmal atrial fibrillation. PMID:26139760

  17. Closure report for N Reactor

    Energy Technology Data Exchange (ETDEWEB)

    1994-01-01

    This report has been prepared to satisfy Section 3156(b) of Public Law 101-189 (Reports in Connection with Permanent Closures of Department of Energy Defense Nuclear Facilities), which requires submittal of a Closure Report to Congress by the Secretary of Energy upon the permanent cessation of production operations at a US Department of Energy (DOE) defense nuclear facility (Watkins 1991). This closure report provides: (1) A complete survey of the environmental problems at the facility; (2) Budget quality data indicating the cost of environmental restoration and other remediation and cleanup efforts at the facility; (3) A proposed cleanup schedule.

  18. Echocardiographic guidance and monitoring of left atrial appendage closure with AtriClip during open-chest cardiac surgery.

    Science.gov (United States)

    Contri, Rachele; Clivio, Sara; Torre, Tiziano; Cassina, Tiziano

    2017-09-12

    Left atrial appendage (LAA) closure prevents thromboembolic risk and avoids lifelong anticoagulation due to atrial fibrillation (AF). Nowadays, AtriClip, a modern epicardial device approved in June 2010, allows external and safe closure of LAA in patients undergoing cardiac surgery during other open-chest cardiac surgical procedures. Such a surgical approach and its epicardial deployment differentiates LAA closure with AtriClip from percutaneous closure techniques such as Watchman (Boston Scientific, Marlborough, MA, USA), Lariat (SentreHEART Inc., Redwood City, CA, USA), and Amplatzer Amulet (St. Jude Medical, St. Paul, MN, USA) device procedures. AtriClip positioning must consider perioperative transesophageal echocardiography (TEE) to confirm LAA anatomical features, to explore the links with neighboring structures, and finally to assess its successful closure. We report a sequence of images to document the role of intraoperative TEE during an elective aortic valve replacement and LAA external closure with AtriClip. © 2017, Wiley Periodicals, Inc.

  19. Closure and Sealing Design Calculation

    Energy Technology Data Exchange (ETDEWEB)

    T. Lahnalampi; J. Case

    2005-08-26

    The purpose of the ''Closure and Sealing Design Calculation'' is to illustrate closure and sealing methods for sealing shafts, ramps, and identify boreholes that require sealing in order to limit the potential of water infiltration. In addition, this calculation will provide a description of the magma that can reduce the consequences of an igneous event intersecting the repository. This calculation will also include a listing of the project requirements related to closure and sealing. The scope of this calculation is to: summarize applicable project requirements and codes relating to backfilling nonemplacement openings, removal of uncommitted materials from the subsurface, installation of drip shields, and erecting monuments; compile an inventory of boreholes that are found in the area of the subsurface repository; describe the magma bulkhead feature and location; and include figures for the proposed shaft and ramp seals. The objective of this calculation is to: categorize the boreholes for sealing by depth and proximity to the subsurface repository; develop drawing figures which show the location and geometry for the magma bulkhead; include the shaft seal figures and a proposed construction sequence; and include the ramp seal figure and a proposed construction sequence. The intent of this closure and sealing calculation is to support the License Application by providing a description of the closure and sealing methods for the Safety Analysis Report. The closure and sealing calculation will also provide input for Post Closure Activities by describing the location of the magma bulkhead. This calculation is limited to describing the final configuration of the sealing and backfill systems for the underground area. The methods and procedures used to place the backfill and remove uncommitted materials (such as concrete) from the repository and detailed design of the magma bulkhead will be the subject of separate analyses or calculations. Post-closure

  20. Overlay Technique for Transcatheter Left Atrial Appendage Closure.

    Science.gov (United States)

    Li, Shuang; Zhu, Mengyun; Lu, Yunlan; Tang, Kai; Zhao, Dongdong; Chen, Wei; Xu, Yawei

    2015-08-01

    The Overlay technique is popular in peripheral artery interventions, but not in coronary or cardiac structural procedures. We present an initial experience using three-episode overlays during a transcatheter left atrial appendage closure. The first overlay was applied to facilitate advancement of the delivery sheath into left atrium. The second overlay was used to navigate the advancement of prepped delivery system containing the compressed occluder into its optimal position in the left atrium. The third overlay facilitated the real-time deployment of the closure device. This case report demonstrates the effectiveness of the overlay technique in facilitating each step of the transcatheter left atrial appendage closure. Copyright © 2015 Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). Published by Elsevier B.V. All rights reserved.

  1. RCRA closure of mixed waste impoundments

    Energy Technology Data Exchange (ETDEWEB)

    Blaha, F.J. [Doty and Associates (United States); Greengard, T.C.; Arndt, M.B. [Rockwell International (United States)

    1989-11-01

    A case study of a RCRA closure action at the Rocky Flats Plant is presented. Closure of the solar evaporation ponds involves removal and immobilization of a mixed hazardous/radioactive sludge, treatment of impounded water, groundwater monitoring, plume delineation, and collection and treatment of contaminated groundwater. The site closure is described within the context of regulatory negotiations, project schedules, risk assessment, clean versus dirty closure, cleanup levels, and approval of closure plans and reports. Lessons learned at Rocky Flats are summarized.

  2. The archaeology of uncommon interventions: Articulating the rationale for transcatheter closure of congenital coronary artery fistulas in asymptomatic children.

    Science.gov (United States)

    McElhinney, Doff B

    2016-02-15

    Transcatheter closure of coronary artery fistulas can be executed successfully in infants and children with few serious procedural complications. Indications for and long-term outcomes of closure of coronary artery fistulas remain poorly defined. Registries may offer the best opportunity for advancing our knowledge about uncommon interventions such as coil or device closure of coronary artery fistulas, but to do so, they must include sufficient data and evaluate factors potentially associated with salutary or adverse outcome.

  3. Transcatheter Closure of Patent Ductus Arteriosus: The Penang Hospital's Experience.

    Science.gov (United States)

    Amir Hamzah, A R; Tiow, C A; Koh, G T; Sharifah, A M

    2011-03-01

    Transcatheter closure of small and moderate sizes of Patent Ductus Arteriosus (PDA) is a standard and well accepted form of treatment. The aim of this study is to describe the experience of transcatheter closure of PDA in Penang Hospital. All patients who underwent transcatheter closure of PDA at our institution between 20th January 2006 and 27th June 2008 were retrospectively identified and studied. There were a total of 66 patients who had undergone transcatheter closure of PDA during this period which comprised of 24 male and 42 female. The PDA was closed by Amplatzer Duct Occluder (ADO) in 31 patients, Gianturco coil in 29 patients and other types of devices in 6 patients. There were 4 patients (6%) who had developed acute complication during the procedure (3 of them developed coil embolization and 1 had bleeding from puncture site). The PDA was successfully close in 95.5% of the study population without any residual PDA shunting. All the patients were alive but 5 of them (4.5%) have some abnormalities (2 has mild left pulmonary stenosis, 3 has small residual). Comparison between ADO and Gianturco coil revealed no significant difference in the outcome. Transcatheter closure of PDA has proven to be safe and effective with good midterm outcome. There was no significant difference between Amplatzer Ductal Occluder and Gianturco coil in term of the outcome.

  4. Gastrotomy closure using bioabsorbable plugs in a canine model.

    Science.gov (United States)

    Cios, Theodore J; Reavis, Kevin M; Renton, David R; Hazey, Jeffrey W; Mikami, Dean J; Narula, Vimal K; Allemang, Matthew T; Davis, S Scott; Melvin, W Scott

    2008-04-01

    The repair of gastric perforation commonly involves simple suture closure using an open or laparoscopic approach. An endolumenal approach using prosthetic materials may be beneficial. The role of bioprosthetics in this instance has not been thoroughly investigated, thus the authors evaluated the feasibility of gastric perforation repair using a bioabsorbable device and quantified gross and histological changes at the injury site. Twelve canines were anesthetized and underwent open gastrotomy. A 1-cm-diameter perforation was created in the anterior wall of the stomach and plugged with a bioabsorbable device. Intralumenal pH was recorded. Canines were sacrificed at one, four, six, eight, and 12 weeks. The stomach was explanted followed by gross and histological examination. The injury site was examined. The relative ability of the device to seal the perforation was recorded, as were postoperative changes. Tissue samples were analyzed for gross and microscopic tissue growth and compared to normal gastric tissue in the same animal as an internal control. A scoring system of -2 to +2 was used to measure injury site healing (-2= leak, -1= no leak and minimal ingrowth, 0= physiologic healing, +1= mild hypertrophic tissue, +2= severe hypertrophic tissue). In all canines, the bioprosthesis successfully sealed the perforation without leak under ex vivo insufflation. At one week, the device maintained its integrity but there was no tissue ingrowth. Histological healing score was -1. At 4-12 weeks, gross examination revealed a healed injury site in all animals. The lumenal portion of the plug was completely absorbed. The gross and histological healing score ranged from -1 to +1. The application of a bioabsorbable device results in durable closure of gastric perforation with physiologic healing of the injury site. This method of gastrotomy closure may aid in the evolution of advanced endoscopic approaches to perforation closure of hollow viscera.

  5. IT SERVICES AVAILABILITY DURING CERN ANNUAL CLOSURE

    CERN Multimedia

    2002-01-01

    Mail, NICE 2000, Web, EDMS (in collaboration with EST Division), General purpose databases, lxbatch, lxplus, Automated tape devices, Castor, Backups, Campus Network, Remedy, Security and VPN services will be available during the CERN annual closure. Problems developing on these services should be addressed within about half a day except on Christmas and New Year evenings, December 25, 2002 and January 1st, 2003. All other services will be left running mostly unattended. No interruptions are scheduled but restoration of the service in case of failure cannot be guaranteed. It should be noted that the Helpdesk will be closed, that no file restores from backups will be possible and damaged tapes will not be processed. An operator service will be maintained and can be reached at extension 75011 or by email to computer.operations@cern.ch. Please remember to shutdown and power off any equipment in your office which is not foreseen to be used during the annual closure before you leave for the holiday.

  6. A comparative study of different imaging modalities for successful percutaneous left atrial appendage closure.

    Science.gov (United States)

    Chow, Danny Hf; Bieliauskas, Gintautas; Sawaya, Fadi J; Millan-Iturbe, Oscar; Kofoed, Klaus F; Søndergaard, Lars; De Backer, Ole

    2017-01-01

    Accurate sizing of the left atrial appendage (LAA) is essential when performing percutaneous LAA closure. This study aimed to compare different LAA imaging modalities and sizing methods in order to obtain successful LAA closure. Percutaneous LAA closure is an increasingly used treatment strategy to prevent stroke in patients with atrial fibrillation. LAA sizing has typically been done by 2D-transoesophageal echocardiography (TEE). Patients who had a preprocedural TEE and preprocedural and postprocedural multislice CT (MSCT) were identified. Preprocedural measurements of LAA ostia and landing zones by 2D-TEE, MSCT and angiography were collected and analysed for those patients with successful LAA closure - i.e. with no contrast leakage at 3-month follow-up MSCT. The study population (n=67) had a mean CHA2DS2-VASc score of 3.0 and HAS-BLED score of 2.7. Fifty-eight patients (87%) were identified to have successful LAA closure. Based on MSCT, 48 LAA sizings (83%) resulted in a correct LAA closure device size selection, whereas with 2D-TEE sizing, only 33 measurements (57%) would have resulted in a correct device size selection (pAmulet, WatchmanFLX), whereas the maximal diameter was the best parameter for the ‘open-end’ Watchman device. Preprocedural MSCT-based LAA closure device size selection proves to be a more accurate method than conventional 2D-TEE-based sizing. Depending on the LAA closure device design, perimeter-derived mean diameter or maximal diameter could be the better sizing method.

  7. [Laparotomy closure in advanced peritonitis].

    Science.gov (United States)

    Bensman, V M; Savchenko, Yu P; Shcherba, S N; Golikov, I V; Triandafilov, K V; Chaykin, V V; Pyatakov, S N; Saakyan, A S; Saakyan, E A

    to improve the results of advanced peritonitis management. 743 patients with advanced peritonitis were studied. Patients were divided into 2 groups depending on treatment strategy. Programmed relaparotomy combined with removable draining musculoaponeurotic seams during laparotomy closure decreased mortality from 47.8±2.7% to 24.1±2.3% (pperitonitis management. Laparotomy closure with only cutaneous seams is indicated in case of persistent abdominal hypertension. Large eventration always requires abdominal wall repair. APACHE-III scale scores have significant prognostic value in patients with advanced peritonitis.

  8. Closure phase and lucky imaging.

    Science.gov (United States)

    Rhodes, William T

    2009-01-01

    Since its introduction by Jennison in 1958, the closure-phase method for removing the effects of electrical path-length errors in radio astronomy and of atmospheric turbulence in optical astronomy has been based on the non-redundant-spacing triple interferometer. It is shown that through application of lucky imaging concepts it is possible to relax this condition, making closure-phase methods possible with redundantly spaced interferometer configurations and thereby widening their range of application. In particular, a quadruple-interferometer can, under lucky imaging conditions, be treated as though it were a triple interferometer. The slit-annulus aperture is investigated as a special case.

  9. Homogeneous orbit closures and applications

    CERN Document Server

    Lindenstrauss, Elon

    2011-01-01

    We give new classes of examples of orbits of the diagonal group in the space of unit volume lattices in R^d for d > 2 with nice (homogeneous) orbit closures, as well as examples of orbits with explicitly computable but irregular orbit closures. We give Diophantine applications to the former, for instance we show that if x is the cubic root of 2 then for any y,z in R liminf |n|=0 (as |n| goes to infinity), where denotes the distance of a real number c to the integers.

  10. Transcatheter vs. surgical closure of patent ductus arteriosus: outcomes and cost analysis

    Directory of Open Access Journals (Sweden)

    Mulyadi M Djer

    2013-07-01

    Full Text Available Background Patent ductus arterious (PDA is a non-cyanotic congenital heart disease (CHD caused by the patency of the arterial duct after birth. For the last three decades, management of PDA with transcatheter closure has been gaining popularity, including in developing countries. However its effectiveness in terms of clinical outcomes and cost may vary among center and has not been thoroughly evaluated yet in Indonesia. Objectives To compare the cost and clinical effectiveness of PDA closure using transcatheter approach compared to surgical ligation. Methods We performed a retrospective review on patients underwent either transcatheter or surgical closure of PDA between January 2000 and December 2006 in Cipto Mangunkusumo Hospital, Jakarta, Indonesia. Clinical outcomes as well as cost were compared using the student T-test and Chi-square for numerical and categorical variables, respectively Results During the study period, 89 patients underwent transcatheter closure using an Amplatzer® device occluder (ADO device and 67 had surgical ligation. Successful PDA closure on first attempt was achieved in 87 (96% and 63 (94% children who underwent transcatheter and surgical closure, respectively (P=1.000. Two children with unsuccessful transcatheter closure eventually had their PDA closed by surgery, whereas one child with residual PDA after surgical closure had his PDA closed by coil. No residual PDA was found in the transcatheter closure group at one-week follow up. Duration of hospitalization was significantly less for patients having transcatheter closure compared to surgery [2.7 (SD 1.5 vs. 6.6 (SD 1.5 days, P<0.0001]. The cost for PDA closure with an Amplatzer® device was more expensive than surgical ligation [Rp. 29,930,000 (SD 57,200 vs. Rp. 12,205,000 (SD 89,300, P< 0.0001]. Conclusion Transcatheter closure is equally effective as surgical ligation in closing the PDA. Less hospitalization is required with transcatheter closure although the

  11. Percutaneous closure of secundum atrial septal defects: Experience of a tertiary referral center

    Directory of Open Access Journals (Sweden)

    Ali Hikmet Kırdök

    2012-03-01

    Full Text Available Objectives: This study was aimed to evaluate our clinical experiences and investigate results of percutaneous closure of secundum atrial septal defects (ASD in our clinic.Results: We retrospectively included 70 patients (19 male, 51 female undergoing percutaneous ASD closure procedure with mean age of 36±14.8 (17-75 in our clinic between March 2008 and January 2010. Defect diameter measured by transesophageal echocardiography was 19.7±6.3 mm (6-32 mm. Device size used for percutaneous closure of ASD was 23.7±6.2 (12-36. Devices used for percutaneous closure were nitinol-based devices including Amplatzer (64.7%, Cardiofix (26.7% and biodegredable BioStar (8.6%. The percutaneous closure procedure was successful at 68 of 70 (97% patients. In 2 patients procedure failed. Failure reason was device embolization in one patient and device strut fracture in other; so these 2 patients referred to surgery. During follow up 2 more patients also referred to surgery because of device embolization in first day control. In 3 patients (4.2% supraventricular arrythmias that are converted to sinus by cardioversion are observed. Mean follow up interval was 18.6±9.6 months (1-44 and during this period peripheral vascular complications, cerebrovascular accidents, thrombus on devices, device erosion or death is not observed.Conclusion: Percutaneous closure of secundum ASD which started to replace surgical treatment of ASD in last decades is safe and effective method in short to mid-term period. However because of potentially serious complication risks it should be performed in special centers by operators who are experienced in treating structural heart diseases.

  12. Feasibility of a mine-wide continuous closure monitoring system for gold mines.

    CSIR Research Space (South Africa)

    Malan, DF

    2000-09-01

    Full Text Available magnetic field ranging device is proposed. As an alternative, a method of estimating the distance to face with reasonable accuracy is proposed. The third generic issue was assigning responsibility for moving the meters (typically every two weeks... the position of the closure transducers ……………………………… 14 2.3 Responsibility for moving the transducers forward on a regular basis ….……..16 3 Alternative hardware designs for a mine-wide closure system………. 18 3.1 Specifications for the closure transducers...

  13. Percutaneous left atrial appendage closure: current state of the art.

    Science.gov (United States)

    Jazayeri, Mohammad-Ali; Vuddanda, Venkat; Parikh, Valay; Lakkireddy, Dhanunjaya R

    2017-01-01

    The authors reviewed the seminal and more recent literature surrounding the major modalities for percutaneous left atrial appendage closure used in contemporary practice, with particular emphasis on safety and efficacy, technical challenges, and future developments. Along with the continued practice of surgical left atrial appendage closure, which has evolved substantially with the advent of clipping techniques, a number of percutaneous methods have been developed to close the left atrial appendage with endocardial, epicardial, and hybrid approaches. The last 18 months has seen the Food and Drug Administration approval of the WATCHMAN device for stroke prevention in the United States, the initiation of a randomized controlled trial to further examine the LARIAT device, and an increasing body of literature surrounding use of the AMPLATZER Amulet in Europe. Left atrial appendage closure is a promising alternative to systemic anticoagulation for stroke prevention in appropriate atrial fibrillation patients. The wealth of available data for the various modalities sheds light on the strengths and limitations of each, postprocedural complications and their management, and new areas for exploration. With a plethora of new devices on the horizon, it is a very exciting time in the field of 'appendage-ology' as we pursue new avenues to optimize care for atrial fibrillation patients.

  14. Omental Herniation: A Rare Complication of Vacuum-Assisted Closure of Infected Sternotomy Wound

    Directory of Open Access Journals (Sweden)

    Philemon Gukop

    2012-01-01

    Full Text Available Vacuum-assisted closure (VAC has recently been adopted as an acceptable modality for management of sternotomy wound infections. Although generally efficacious, the use of negative pressure devices has been associated with complications such as bleeding, retention of sponge, and empyema. We report the first case of greater omental hernia as a rare complication of vacuum-assisted closure of sternal wound infection following coronary artery bypass grafting.

  15. Local lysis with Alteplase for the treatment of acute embolic leg ischemia following the use of the Duett {sup trademark} closure device: preliminary results; Lokale Alteplase-Lyse zur Therapie der akuten embolischen Beinischaemie nach Einsatz des Duett {sup trademark} -Verschluss-Systems: vorlaeufige Ergebnisse

    Energy Technology Data Exchange (ETDEWEB)

    Schuermann, K.; Buecker, A.; Wingen, M.; Tacke, J.; Wein, B.; Guenther, R.W. [Klinik fuer Radiologische Diagnostik des Universitaetsklinikums der RWTH Aachen (Germany); Janssens, U. [Medizinische Klinik I (Kardiologie) des Universitaetsklinikums der RWTH Aachen (Germany)

    2004-04-01

    Purpose: To analyze retrospectively the result of the alteplase lysis therapy of embolic complications following the use of the Duett closure device. Methods and Materials: For 3.5 years, the Duett closure device was used in 1,398 angiographies to close the femoral puncture site. The Duett device consists of a balloon and a liquid procoagulant containing collagen and thrombin, which is injected into the puncture tract under endovascular balloon protection of the arterial puncture site. In 9 patients (0.64%), the procoagulant was incidentally injected into the femoral artery causing acute leg ischemia. Eight patients received local lysis therapy with alteplase via a contralateral femoral access. One patient underwent surgery. On average, 21 mg alteplase (4-35 mg) were administered within 14 h (4-21 h). The course of the lysis was followed angiographyically and clinically. All patients were inteerviewed by telephone 23 months (4-35 months) later.Results: In 3 patients, lysis was complete. In 5 patients, only little thrombotic material remained. In all patients, symptoms of ischemia resolved completely within the first hours after initiation of lysis. In 5 cases, bleeding occurred at the puncture site closed with the Duett device during lysis, including development of a false aneurysm in 2 cases. Complications led to premature termination (n=2) or interruption of the lysis (n=3). All complications were treated conservatively. Clinically, long-term sequelae were paresthesia and hypoesthesia in the lower leg and foot in 2 patients treated with lysis, and in the patient who underwent surgery. (orig.) [German] Ziel: Das Ergebnis der Alteplase-Lysetherapie von Embolien nach Einsatz des Duett-Verschluss-Systems wurde retrospektiv untersucht. Methoden: Innerhalb von 3,5 Jahren wurde nach 1398 Angiographien das Duett-System zum Verschluss der femoralen Punktionsstelle eingesetzt. Das System besteht aus einem Ballon und einem fluessigen Prokoagulans (Kollagen, Thrombin), das

  16. Novel use of the medtronic micro vascular plug for PDA closure in preterm infants.

    Science.gov (United States)

    Wang-Giuffre, Elizabeth W; Breinholt, John P

    2017-05-01

    To describe a single institution experience with a new endovascular occlusion device used for transcatheter patent ductus arteriosus (PDA) closure in preterm infants. The PDA is a defect largely treated via cardiac catheterization except for the smallest patients. Medical records and catheterization reports of all premature neonates who underwent PDA device closure with the Medtronic Micro Vascular Plug (MVP) (Medtronic, Minneapolis, MN) between September 2015 and June 2016 were reviewed. Procedural details, complications, and short term outcomes were recorded. Eight premature neonates born at a median gestational age of 28 weeks (23 to 35 weeks) underwent PDA closure with a Medtronic MVP. All devices were deployed via a 4F angled Glide catheter in prograde fashion without arterial access. Median age and weight was 52 days (15-112 days) and 2,550 g (1,800-3,500 g), respectively. Fluoroscopy and echocardiography were utilized for the procedure. Complete closure was achieved in all patients with no procedural complications, pulmonary artery or aortic obstruction or death. One device embolized 9 days after deployment and was successfully retrieved. This study describes transcatheter PDA closure with the Medtronic MVP. The major advantage is the ability to deliver the device via a standard catheter in prograde fashion, and avoid the hemodynamic instability produced by rigid delivery sheaths. It also further validates the ability to close the PDA without arterial access, providing improved access to this procedure to smaller and more vulnerable children. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  17. Telephone switchboard closure | 19 December

    CERN Multimedia

    2014-01-01

    Exceptionally, the telephone switchboard will close at 4 p.m. on Friday, 19 December, instead of the usual time of 6 p.m., to allow time for closing all systems properly before the annual closure. Therefore, switchboard operator assistance to transfer calls from/to external lines will stop. All other phone services will run as usual.

  18. Abdominal wound closure: current perspectives

    Directory of Open Access Journals (Sweden)

    Williams ZF

    2015-12-01

    Full Text Available Zachary F Williams, William W Hope Department of Surgery, South East Area Health Education Center, New Hanover Regional Medical Center, Wilmington, NC, USA Abstract: This review examines both early and late wound complications following laparotomy closure, with particular emphasis on technical aspects that reduce hernia formation. Abdominal fascial closure is an area of considerable variation within the field of general surgery. The formation of hernias following abdominal wall incisions continues to be a challenging problem. Ventral hernia repairs are among the most common surgeries performed by general surgeons, and despite many technical advances in the field, incisional hernia rates remain high. Much attention and research has been directed to the surgical management of hernias. Less focus has been placed on prevention of hernia formation despite its obvious importance. This review examines the effects of factors such as the type of incision, suture type and size, closure method, patient risk factors, and the use of prophylactic mesh. Keywords: incisional, abdominal, hernia, prevention, wound closure techniques 

  19. Vacuum assisted closure in coloproctology

    NARCIS (Netherlands)

    Bemelman, W.A.

    2009-01-01

    Vacuum-assisted closure has earned its indications in coloproctology. It has been described with variable results in the treatment of large perineal defects after abdominoperineal excision, in the treatment of stoma dehiscence and perirectal abscesses. The most promising indication for

  20. Long-term outcome of percutaneous closure of secundum-type atrial septal defects in adults.

    Science.gov (United States)

    Luermans, Justin G L M; Post, Martijn C; ten Berg, Jurriën M; Plokker, H W Thijs; Suttorp, Maarten J

    2010-11-01

    Transcatheter closure of the secundum-type atrial septal defect (ASD) is widely practised. We report complications and efficacy of percutaneous ASD closure in adults using the Amplatzer ASD occluder and the Cardioseal/Starflex device during long-term follow-up. Between 1996 and 2008 percutaneous ASD closure was performed in 133 patients (mean age 46.8 ± 16.9 years; 36 men) by using the Amplatzer(r) device in 104 patients and the Cardioseal/Starflex device in 29. During a mean follow-up of 3.4 ± 2.8 years the occurrence of major complications was higher in patients with the Cardioseal/Starflex compared to patients with the Amplatzer(r) devices (17.2 vs. 2.9%, log rank, P=0.005), due to a higher embolisation rate (13.8 vs. 1.0%, log rank, P=0.002). In univariable analysis, the implantation of a Cardioseal/Starflex device (OR 6.0 (CI 1.4-25.2); P=0.01) and a larger device diameter (OR 1.1 (CI 1.0-1.2); P=0.04) were found to be predictors of the occurrence of major complications. Minor complications occurred in 10.5%, recurrent thrombo-embolism in 2.3% and residual shunting at six months was 13.9% without differences between devices. NYHA class improved from 1.8 ± 0.6 before to 1.2 ± 0.4 after closure (P<0.001) without differences between devices. During long-term follow-up, percutaneous ASD closure in adults is safe and effective when using the Amplatzer(r) device. Larger Cardioseal/Starflex devices are related to a higher embolisation rate. Randomised trials are needed.

  1. Multidisciplinary Assessment in Optimising Results of Percutaneous Patent Foramen Ovale Closure.

    Science.gov (United States)

    Davies, Allan; Ekmejian, Avedis; Collins, Nicholas; Bhagwandeen, Rohan

    2017-03-01

    Percutaneous patent foramen ovale (PFO) closure is a therapeutic option to prevent recurrent cerebral ischaemia in patients with cryptogenic stroke and transient cerebral ischaemia (TIA). The apparent lack of benefit seen in previous randomised trials has, in part, reflected inclusion of patients with alternate mechanisms of stroke. The role of formal neurology involvement in accurately delineating the likely aetiology of stroke or TIA is crucial in appropriate identification of patients for device closure. Furthermore, as the benefits of device closure may accrue over time, long-term follow-up is essential to define the role of device closure in management of presumed cryptogenic stroke. We retrospectively reviewed our experience with percutaneous PFO device closure since 2005. All subjects who underwent PFO closure at John Hunter and Lake Macquarie Private Hospitals were included in the study. All patients referred for device closure following cryptogenic stroke or TIA had first undergone formal neurology review with appropriate imaging and exclusion of paroxysmal atrial arrhythmia. Patients with a history of transient ischaemic attack (TIA) are frequently referred to a specialised clinic, aimed to identify patients with conditions not referable to cerebral ischaemia, with investigations initiated by the specialist clinic to elucidate an underlying aetiology. Outcome data was derived from the Hunter New England Area Local Health District Cardiac and Stroke Outcomes Unit, in addition to review of the medical record. The Cardiac and Stroke Outcomes Unit prospectively identified all patients presenting with stroke, TIA and atrial fibrillation. One hundred and twelve consecutive patients undergoing percutaneous patent foramen ovale closure between 2005 and 2015 were identified. The average age was 42.7 years and 57 (50.9%) patients were male. Cryptogenic stroke (68.8%) and transient cerebral ischaemia (23.2%) were the most common indications for PFO closure, with the

  2. 40 CFR 265.112 - Closure plan; amendment of plan.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 25 2010-07-01 2010-07-01 false Closure plan; amendment of plan. 265... DISPOSAL FACILITIES Closure and Post-Closure § 265.112 Closure plan; amendment of plan. (a) Written plan... have a written closure plan. Until final closure is completed and certified in accordance with §...

  3. COMPARATIVE STUDY OF LAPAROSCOPIC CLOSURE OPEN PEPTIC PERFORATION CLOSURE

    Directory of Open Access Journals (Sweden)

    Vivek

    2015-10-01

    Full Text Available Laparoscopic closure of perforated duodenal ulcer was first performed in the year 1990 . Due to its advantage of better view of the peritoneal cavity an opportunity for thorough lavage and avoidance of upper abdominal incision, with its related complication, especially in high – ri sk patients, this procedure has gained popularity all over the world. Approximately 10 - 20% of patients suffering from peptic ulcer develop perforation of stomach or duodenum in which, chemical peritonitis develop initially from gastric secretion and duoden al secretion the condition is life threatening. Early diagnosis and treatment is extremely important. Mortality will increase up if perforation exists more than 24 to 48 hours. Usually surgical intervention of simple closure with omental patch of the perforation is required. this study aims at evaluating efficacy , safety and outcome of laparoscopic surgery for perforated duodenal ulcer patients admitted during period Jan 2009 to Dec 2012 at tertiary hospital in north Karnataka A total of 61cases diagnosed as peritonitis secondary to duodenal ulcer perforation were involved in the study 30underwent open perforation closure and 31 cases underwent lap closure. Peptic ulcers are focal defects in the gastric or duodenal mucosa which extend into the sub mucosa or deeper. they may be acute or chronic and ultimately are caused by on imbalance between the action of peptic acid and mucosal defenses peptic ulcer remains a common outpatient diagnosis, but the number of elective operations for peptic ul cer disease have decreased dramatically over the past 30 decades due to the advent of H2 blockers However the incidence of emergency surgeries, and death rate associated with peptic ulcer are same

  4. Generalized Convective Quasi-Equilibrium Closure

    Science.gov (United States)

    Yano, Jun-Ichi; Plant, Robert

    2016-04-01

    Arakawa and Schubert proposed convective quasi-equilibrium as a basic principle for closing their spectrum mass-flux convection parameterization. In deriving this principle, they show that the cloud work function is a key variable that controls the growth of convection. Thus, this closure hypothesis imposes a steadiness of the cloud work function tendency. This presentation shows how this principle can be generalized so that it can also encompasses both the CAPE and the moisture-convergence closures. Note that the majority of the current mass-flux convection parameterization invokes a CAPE closure, whereas the moisture-convergence closure was extremely popular historically. This generalization, in turn, includes both closures as special cases of convective quasi-equilibrium. This generalization further suggests wide range of alternative possibilities for convective closure. In general, a vertical integral of any function depending on both large-scale and convective-scale variables can be adopted as an alternative closure variables, leading to an analogous formulation as Arakawa and Schubert's convective quasi-equilibrium formulation. Among those, probably the most fascinating possibility is to take a vertical integral of the convective-scale moisture for the closure. Use of a convective-scale variable for closure has a particular appeal by not suffering from a loss of predictability of any large-scale variables. That is a main problem with any of the current convective closures, not only for the moisture-convergence based closure as often asserted.

  5. Closure constraints for hyperbolic tetrahedra

    CERN Document Server

    Charles, Christoph

    2015-01-01

    We investigate the generalization of loop gravity's twisted geometries to a q-deformed gauge group. In the standard undeformed case, loop gravity is a formulation of general relativity as a diffeomorphism-invariant SU(2) gauge theory. Its classical states are graphs provided with algebraic data. In particular closure constraints at every node of the graph ensure their interpretation as twisted geometries. Dual to each node, one has a polyhedron embedded in flat space R^3. One then glues them allowing for both curvature and torsion. It was recently conjectured that q-deforming the gauge group SU(2) would allow to account for a non-vanishing cosmological constant Lambda, and in particular that deforming the loop gravity phase space with real parameter q>0 would lead to a generalization of twisted geometries to a hyperbolic curvature. Following this insight, we look for generalization of the closure constraints to the hyperbolic case. In particular, we introduce two new closure constraints for hyperbolic tetrahe...

  6. Effectiveness of percutaneous closure of patent foramen ovale for hypoxemia.

    Science.gov (United States)

    Fenster, Brett E; Nguyen, Bryant H; Buckner, J Kern; Freeman, Andrew M; Carroll, John D

    2013-10-15

    The aim of this study was to evaluate the ability of percutaneous patent foramen ovale (PFO) closure to improve systemic hypoxemia. Although PFO-mediated right-to-left shunt (RTLS) is associated with hypoxemia, the ability of percutaneous closure to ameliorate hypoxemia is unknown. Between 2004 and 2009, 97 patients who underwent PFO closure for systemic hypoxemia and dyspnea that was disproportionate to underlying lung disease were included for evaluation. All patients exhibited PFO-mediated RTLS as determined by agitated saline echocardiography. Procedural success was defined as implantation of a device without major complications and mild or no residual shunt at 6 months. Clinical success was defined as a composite of an improvement in New York Heart Association (NYHA) functional class, reduction of dyspnea symptoms, or decreased oxygen requirement. Procedural success was achieved in 96 of 97 (99%), and clinical success was achieved in 68 of 97 (70%). The presence of any moderate or severe interatrial shunt by agitated saline study (odds ratio [OR] = 4.7; p <0.024), NYHA class at referral (OR = 2.9; p <0.0087), and 10-year increase in age (OR = 1.8; p <0.0017) increased likelihood of clinical success. In contrast, a pulmonary comorbidity (OR = 0.18; p <0.005) and male gender (OR = 0.30; p <0.017) decreased the likelihood of success. In conclusion, based on the largest single-center experience of patients referred for PFO closure for systemic hypoxemia, PFO closure was a mechanically effective procedure with an associated improvement in echocardiographic evidence of RTLS, NYHA functional class, and oxygen requirement. Copyright © 2013 Elsevier Inc. All rights reserved.

  7. Cardiac procedures to prevent stroke: patent foramen ovale closure/left atrial appendage occlusion.

    Science.gov (United States)

    Freixa, Xavier; Arzamendi, Dabit; Tzikas, Apostolos; Noble, Stephane; Basmadjian, Arsene; Garceau, Patrick; Ibrahim, Réda

    2014-01-01

    Stroke is a major contributor to population morbidity and mortality. Cardiac thromboembolic sources are an important potential cause of stroke. Left atrial appendage (LAA) thromboembolism in association with atrial fibrillation is a major contributor to stroke occurrence, particularly in elderly individuals. Patent foramen ovale (PFO) acts as a potential conduit from the right-sided circulation to the brain, and has been suggested to be an important factor in cryptogenic stroke in the young patients. Advances in interventional cardiology have made it possible to deal with these potential stroke sources (LAA and PFO), but the available methods have intrinsic limitations that must be recognized. Furthermore, the potential value of LAA and PFO closure depends on our ability to identify when the target structure is importantly involved in stroke risk; this is particularly challenging for PFO. This article addresses the clinical use of PFO and LAA closure in stroke prevention. We discuss technical aspects of closure devices and methods, questions of patient selection, and clinical trials evidence. We conclude that for PFO closure, the clinical trials evidence is thus far negative in the broad cryptogenic stroke population, but closure might nevertheless be indicated for selected high-risk patients. LAA closure has an acceptable balance between safety and efficacy for atrial fibrillation patients with high stroke risk and important contraindications to oral anticoagulation. Much more work needs to be done to optimize the devices and techniques, and better define patient selection for these potentially valuable procedures.

  8. Transcatheter closure of small ductus arteriosus with amplatzer vascular plug

    Directory of Open Access Journals (Sweden)

    Eunhyun Cho

    2013-09-01

    Full Text Available Purpose: The purpose of this study was to share our experience of transcatheter closure of small patent ductus arteriosus (PDA by using an Amplatzer vascular plug (AVP.&lt;br&gt; Methods: We reviewed the medical records of 20 patients who underwent transcatheter closure at Samsung Medical Center and Sejong General Hospital from January 2008 to August 2012. The size and shape of the PDAs were evaluated by performing angiograms, and the PDA size and the AVP devices size were compared.&lt;br&gt;Results: The mean age of the patients was 54.9±45.7 months old. The PDAs were of type C (n=5, type D (n=12 and type E (n=3. The mean pulmonary end diameter of the PDA was 1.7±0.6 mm, and the aortic end diameter was 3.6±1.4 mm. The mean length was 7.3±1.8 mm. We used 3 types of AVP devices: AVP I (n=5, AVP II (n=7, and AVP IV (n=8. The ratio of AVP size to the pulmonary end diameter was 3.37±1.64, and AVP size/aortic end ratio was 1.72±0.97. The aortic end diameter was significantly larger in those cases repaired with AVP II than in the others (P =0.002. The AVP size did not significantly correlate with the PDA size, but did correlate with smaller ratio of AVP size to aortic end diameter (1.10±0.31, P =0.032. &lt;br&gt;Conclusion: Transcatheter closure of small PDA with AVP devices yielded satisfactory outcome. AVP II was equally effective with smaller size of device, compared to others.

  9. Transhepatic approach to closure of patent foramen ovale: report of 2 cases in adults.

    Science.gov (United States)

    Hussain, Jamal; Strumpf, Robert; Ghandforoush, Aslan; Jamal, Ayman; Diethrich, Edward

    2010-01-01

    Patent foramen ovale is increasingly diagnosed in patients who are undergoing clinical study for cryptogenic stroke or migraine. In addition, patent foramen ovale is often suspected as a cause of paradoxical embolism in patients who present with arterial thromboembolism. The femoral venous approach to closure has been the mainstay. When the femoral approach is not feasible, septal occluder devices have been deployed via a transjugular approach.Herein, we describe 2 cases of patent foramen ovale in which the transhepatic approach was used for closure. To our knowledge, this is the 1st report of a transhepatic approach to patent foramen ovale closure in an adult patient. Moreover, no previous case of patent foramen ovale closure has been reported in a patient with interrupted inferior vena cava.

  10. Percutaneous closure of patent ductus arteriosus: Experience of a tertiary referral center

    Directory of Open Access Journals (Sweden)

    Hasan Kaya

    2013-01-01

    Full Text Available Objective: We sought to evaluate our clinical experienceand short-term results of percutaneous closure of patentductus arteriosus (PDA.Methods: We studied 20 patients (17 female, mean age24±8 years undergoing percutaneous closure of PDA betweenMarch 2010-March 2013 in our clinic. Amplatzerduct occluder (ADO I was used in 13 patients and ADOII was used in 7 patients for PDA closure. Clinical characteristicsof patients, properties of percutaneous closureintervention, complications and short-term results areevaluated.Results: The mean ductus waist diameter measured byangiographic examination was 5±2 mm (2-9 mm. Procedurewas successfully performed in all patients. Occluderdevice embolization was occurred in one patientin whom device was retrieved by snare catheter and PDAwas successfully closed with same device. The early totalocclusion rate was 85%. Occlusion rate as determinedby echocardiographic control performed the day afterwas 95% whereas 100% at first month. In the follow-up of19±9 months, no complications were observed.Conclusion: Percutaneous closure of PDA using ADO Iand II devices are safe and effective.Key words: patent ductus arteriosus, percutaneous closure,Amplatzer duct occluder

  11. Roles of real-time three-dimensional transesophageal echocardiography in peri-operation of transcatheter left atrial appendage closure

    Science.gov (United States)

    Zhou, Qing; Song, Hongning; Zhang, Lan; Deng, Qing; Chen, Jinling; Hu, Bo; Wang, Yijia; Guo, Ruiqiang

    2017-01-01

    Abstract Left atrial appendage (LAA) closure is a new treatment option for the prevention of stroke in patients with nonvalvular atrial fibrillation (AF). Conventional 2-dimensional transesophageal echocardiography (2D TEE) has some limitations in the imaging assessment of LAA closure. Real-time 3-dimensional transesophageal echocardiography (RT-3D TEE) allows for detailed morphologic assessment of the LAA. In this study, we aim to determine the clinical values of RT-3D TEE in the periprocedure of LAA closure. Thirty-eight persistent or paroxysmal AF patients with indications for LAA closure were enrolled in this study. RT-3D TEE full volume data of the LAA were recorded before operation to evaluate the anatomic feature, the landing zone dimension, and the depth of the LAA. On this basis, selection of LAA closure device was carried out. During the procedure, RT-3D TEE was applied to guide the interatrial septal puncture, device operation, and evaluate the occlusion effects. The patients were follow-up 1 month and 3 months postclosure. Twenty-eight (73.7%) patients with AF received placement of LAA occlusion device under RT-3D TEE. Eleven cases with single-lobe LAAs were identified using RT-3D TEE, among which 4 showed limited depth. Seventeen cases showed bilobed or multilobed LAA. Seven cases received LAA closure using Lefort and 21 using LAmbre based on the 3D TEE and radiography. The landing zone dimension of the LAA measured by RT-3D TEE Flexi Slice mode was better correlated with the device size used for occlusion (r = 0.90) than 2D TEE (r = 0.88). The interatial septal puncture, the exchange of the sheath, as well as the release of the device were executed under the guidance of RT-3D TEE during the procedure. The average number of closure devices utilized for optimal plugging was (1.11 ± 0.31). There were no clinically unacceptable residual shunts, pericardial effusion, or tamponade right after occlusion. All the patients had the device well

  12. 49 CFR 178.360-4 - Closure devices.

    Science.gov (United States)

    2010-10-01

    ... the body of the 2R vessel per (ANSI) Standard B16.5 or (AWWA) Standard C207-55, section 10 (IBR, see...) For nominal pipe sizes, 6, 8, 10, and 12 inches, AWWA Standard C207-55, Table 1, class B, may be used..., nominal pipe size, the following table with the same configuration as illustrated in AWWA C207-55, Table...

  13. Closure constraints for hyperbolic tetrahedra

    Science.gov (United States)

    Charles, Christoph; Livine, Etera R.

    2015-07-01

    We investigate the generalization of loop gravity's twisted geometries to a q-deformed gauge group. In the standard undeformed case, loop gravity is a formulation of general relativity as a diffeomorphism-invariant SU(2) gauge theory. Its classical states are graphs provided with algebraic data. In particular, closure constraints at every node of the graph ensure their interpretation as twisted geometries. Dual to each node, one has a polyhedron embedded in flat space {{{R}}3}. One then glues them, allowing for both curvature and torsion. It was recently conjectured that q-deforming the gauge group SU(2) would allow us to account for a non-vanishing cosmological constant Λ \

  14. 100-D Ponds closure plan. Revision 1

    Energy Technology Data Exchange (ETDEWEB)

    Petersen, S.W.

    1997-09-01

    The 100-D Ponds is a Treatment, Storage, and Disposal (TSD) unit on the Hanford Facility that received both dangerous and nonregulated waste. This Closure Plan (Rev. 1) for the 100-D Ponds TSD unit consists of a RCRA Part A Dangerous Waste Permit Application (Rev. 3), a RCRA Closure Plan, and supporting information contained in the appendices to the plan. The closure plan consists of eight chapters containing facility description, process information, waste characteristics, and groundwater monitoring data. There are also chapters containing the closure strategy and performance standards. The strategy for the closure of the 100-D Ponds TSD unit is clean closure. Appendices A and B of the closure plan demonstrate that soil and groundwater beneath 100-D Ponds are below cleanup limits. All dangerous wastes or dangerous waste constituents or residues associated with the operation of the ponds have been removed, therefore, human health and the environment are protected. Discharges to the 100-D Ponds, which are located in the 100-DR-1 operable unit, were discontinued in June 1994. Contaminated sediment was removed from the ponds in August 1996. Subsequent sampling and analysis demonstrated that there is no contamination remaining in the ponds, therefore, this closure plan is a demonstration of clean closure.

  15. 40 CFR 264.112 - Closure plan; amendment of plan.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 25 2010-07-01 2010-07-01 false Closure plan; amendment of plan. 264... Closure and Post-Closure § 264.112 Closure plan; amendment of plan. (a) Written plan. (1) The owner or operator of a hazardous waste management facility must have a written closure plan. In addition,...

  16. IT Services availability during CERN annual closure

    CERN Multimedia

    2003-01-01

    Mail, Cern Windows (NICE ),  Web services,  LXPLUS, LXBATCH, Automated tape devices, Castor, Backups, software license servers, Sundev, CVS and Print Servers, CDS and Agenda-Maker, EDMS (in collaboration with EST Division), CMS disc servers, Campus Network,  Remedy, Security and VPN services will be available during the CERN annual closure. The physics database cluster, replication location service as well as accdb, cerndb and admsdb are the only databases available, CCDB will be closed for public access. Problems developing on scheduled services should be addressed within about half a day except around  Christmas Eve and Christmas Day ( 24 and 25th December ) and New Year's Eve and New Years Day (31st December and 1st Janauary. All other services will be left running mostly unattended. No interruptions are scheduled but restoration of the service in case of failure cannot be guaranteed. Please note that the Helpdesk will be closed, that no file restores from backups will be possible and damaged tapes wi...

  17. IT Services availability during CERN annual closure

    CERN Multimedia

    2003-01-01

    Mail, Cern Windows (NICE ),  Web services,  LXPLUS, LXBATCH, Automated tape devices, Castor, Backups, software license servers, Sundev, CVS and Print Servers, CDS and Agenda-Maker, EDMS (in collaboration with EST Division), CMS disc servers, Campus Network,  Remedy, Security and VPN services will be available during the CERN annual closure. The physics database cluster, replication location service as well as accdb, cerndb and admsdb are the only databases available, CCDB will be closed for public access. Problems developing on scheduled services should be addressed within about half a day except around  Christmas Eve and Christmas Day ( 24 and 25th December ) and New Year's Eve and New Years Day (31st December and 1st Janauary. All other services will be left running mostly unattended. No interruptions are scheduled but restoration of the service in case of failure cannot be guaranteed. Please note that the Helpdesk will be closed, that no file restores from backups will be possible and damaged tapes wi...

  18. Percutaneous closure of secundum type atrial septal defects:More than 5-year follow-up

    Institute of Scientific and Technical Information of China (English)

    Roel; JR; Snijder; Maarten; J; Suttorp; Jurri?n; M; Ten; Berg; Martijn; C; Post

    2015-01-01

    AIM: To investigate long-term efficacy of two different devices more than five years after percutaneous atrial septal defect(ASD) closure in adults.METHODS: All patients who underwent percutaneous closure of an ASD in the St. Antonius Hospital, Nieuwegein, The Netherlands, between February 1998 and December 2006 were included. Percutaneous closure took place under general anaesthesia and transesophageal echocardiographic moni toring. Transthoracic echocardiography(TTE) was performed 24 h post-procedure to visualize the device position and to look for residual shunting using color Doppler. All complications were registered. All patients were invited for an outpatient visit and contrast TTE more than 5-years after closure. Efficacy was based on the presence of a residual right-to-left shunt(RLS), graded as minimal, moderate or severe. The presence of a residual left-to-right shunt(LRS) was diagnosed using color Doppler, and was not graded. Descriptive statistics were used for patients’ characteristics. Univariate analysis was used to identify predictors for residual shunting.RESULTS: In total, 104 patients(mean age 45.5 ± 17.1 years) underwent percutaneous ASD closure using an Amplatzer device(ASO) in 76 patients and a Cardioseal/Starflex device(CS/SF) in 28 patients. The mean follow-up was 6.4 ± 3.4 years. Device migration occurred in 4 patients of whom two cases occurred during the index hospitalization(1 ASO, 1 CS/SF). The other 2 cases of device migration occurred during the first 6 mo of follow-up(2 CS/SF). The recurrent thrombo-embolic event rate was similar in both groups: 0.4% per follow-up year. More than 12 mo post-ASD closure and latest follow-up, new-onset supraventricular tachyarrhythmia’s occurred in 3.9% and 0% for the ASO and CS/SF group, respectively. The RLS rate at latest follow-up was 17.4%(minimal 10.9%, moderate 2.2%, severe 4.3%) and 45.5%(minimal 27.3%, moderate 18.2%, severe 0%) for the ASO- and CS/SF groups, respectively. There was no

  19. Structural determinants of hospital closure.

    Science.gov (United States)

    Longo, D R; Chase, G A

    1984-05-01

    In a retrospective case-control study, structural characteristics of hospitals that closed during the years 1976-1980 were contrasted with three comparison groups: hospitals that were acquired in a merger; hospitals that joined a multihospital system; and hospitals that remained autonomously opened, to investigate these characteristics as predictors of closure. Characteristics investigated included environmental, structural, and process variables. The independent variables were measured 5 years prior to outcome. Findings indicate that closed hospitals resemble hospitals acquired in a merger ("failure"), and likewise autonomous hospitals resemble hospitals that join a multihospital system ("success"). The most important predictors of hospital failure were the physician-to-population ratio, the East North Central and West North Central census regions, the level of diversification, low occupancy rate, location in a standard metropolitan statistical area, the chief executive officer's lack of affiliation in the American College of Hospital Administrators, profit status, bed size of less than 50, and presence in a state with a rate-setting agency. Surprisingly, this study shows the bed-to-population ratio to be unrelated to closure. In addition, the findings strongly support the open-system perspective, which, unlike the closed-system perspective, is concerned with the vulnerability of the organization to the uncontrollable and often unpredictable influences of the environment.

  20. Transesophageal echocardiography for incremental value of Amplatezer cribriform septal occluder for percutaneous transcatheter closure of complex septal defects: Case series

    Directory of Open Access Journals (Sweden)

    Shen Kou Tsai

    2017-06-01

    Conclusion: Our patients with complex septal defects were successfully treated by transcatheter closure using an Amplazter cribriform septal occluder device with careful planning based on patient presentation and close interdisciplinary collaboration. RT 3D color Doppler TEE provided precise information for the selection of the appropriate occluder device and facilitated the procedure by guiding the catheter through the often challenging patient anatomy.

  1. Closure of a short patent ductus arteriosus using an atrial septal occluder

    Institute of Scientific and Technical Information of China (English)

    Keyhan Sayadpour Zanjani

    2010-01-01

    @@ Patent ductus arteriosus (PDA) device closure was first attempted by Porstmann et al1 in 1967. Due to the rapid development in this field, it is the therapy of choice in current era. As most of PDAs have conical shape, Amplatzer PDA occluders were designed to fit into these ducts.

  2. 40 CFR 264.178 - Closure.

    Science.gov (United States)

    2010-07-01

    ... Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES (CONTINUED) STANDARDS FOR OWNERS AND OPERATORS OF HAZARDOUS WASTE TREATMENT, STORAGE, AND DISPOSAL FACILITIES Use and Management of Containers § 264.178 Closure. At closure, all hazardous waste and hazardous waste residues must be removed...

  3. 40 CFR 264.351 - Closure.

    Science.gov (United States)

    2010-07-01

    ... Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES (CONTINUED) STANDARDS FOR OWNERS AND OPERATORS OF HAZARDOUS WASTE TREATMENT, STORAGE, AND DISPOSAL FACILITIES Incinerators § 264.351 Closure. At closure the owner or operator must remove all hazardous waste and hazardous waste...

  4. 50 CFR 665.666 - Closures.

    Science.gov (United States)

    2010-10-01

    ... 50 Wildlife and Fisheries 9 2010-10-01 2010-10-01 false Closures. 665.666 Section 665.666 Wildlife and Fisheries FISHERY CONSERVATION AND MANAGEMENT, NATIONAL OCEANIC AND ATMOSPHERIC ADMINISTRATION... § 665.666 Closures. (a) If the Regional Administrator determines that the harvest quota for any...

  5. Key financial ratios can foretell hospital closures.

    Science.gov (United States)

    Lynn, M L; Wertheim, P

    1993-11-01

    An analysis of various financial ratios sampled from open and closed hospitals shows that certain leverage, liquidity, capital efficiency, and resource availability ratios can predict hospital closure up to two years in advance of the closure with an accuracy of nearly 75 percent.

  6. Spontaneous closure of traumatic tympanic membrane perforations

    DEFF Research Database (Denmark)

    Jellinge, Marlene Ersgaard; Kristensen, S.; Larsen, K

    2015-01-01

    BACKGROUND: The treatment of traumatic tympanic membrane perforations varies in different investigations, ranging from observation to early surgical repair. The present study aimed to focus on the closure rate and the closure time in a group of patients treated with a watchful waiting policy. MET...

  7. Acute angle closure glaucoma following ileostomy surgery

    Directory of Open Access Journals (Sweden)

    Mariana Meirelles Lopes

    2015-02-01

    Full Text Available Angle-closure glaucoma can be induced by drugs that may cause pupillary dilatation. We report a case of a patient that developed bilateral angle closure glaucoma after an ileostomy surgery because of systemic atropine injection. This case report highlights the importance of a fast ophthalmologic evaluation in diseases with ocular involvement in order to make accurate diagnoses and appropriate treatments.

  8. To close or not to close: contemporary indications for patent foramen ovale closure.

    Science.gov (United States)

    Zier, Lucas S; Sievert, Horst; Mahadevan, Vaikom S

    2016-11-01

    Patent foramen ovale (PFO) is a common congenital cardiac abnormality and that has been associated with several disease processes including transient ischemic attacks (TIA), stroke, migraine headaches with aura, decompression sickness, platypnea-orthodeoxia syndrome, and shunt induced cyanosis. Controversy exists regarding closure of PFO as a therapeutic treatment modality for these disease processes. This review addresses the contemporary clinical indications for PFO closure. Areas covered: We conducted a comprehensive literature search of contemporary research studies focusing on randomized trials and meta-analyses comparing medical therapy and device closure of PFOs for the treatment of PFO associated clinical syndromes. We synthesized this literature into a review addressing indications for PFO closure in stroke, TIA, migraine headaches with aura, decompression sickness, platypnea-orthodeoxia syndrome, and shunt induced cyanosis. Expert commentary: Because in many PFO associated conditions it can be difficult to determine the degree to which the PFO is a causative factor in the disease process, we recommend a comprehensive diagnostic evaluation to exclude other obvious etiologies of PFO associated conditions before implicating the PFO and proceeding with closure. However in the properly selected patient population there is growing clinical experience and experimental evidence suggesting that closure of PFO is a safe and effective treatment modality.

  9. Intermittent acute angle closure glaucoma and chronic angle closure following topiramate use with plateau iris configuration

    Directory of Open Access Journals (Sweden)

    Rajjoub LZ

    2014-07-01

    Full Text Available Lamise Z Rajjoub, Nisha Chadha, David A Belyea Department of Ophthalmology, The George Washington University, Washington, DC, USA Abstract: This is a case report describing recurrent intermittent acute angle closure episodes in the setting of topiramate use in a female suffering from migraines. Despite laser peripheral iridotomy placement for the pupillary block component, and the discontinuation of topiramate, the acute angle closure did not resolve in the left eye with chronic angle closure and the patient required urgent trabeculectomy. The right eye responded to laser peripheral iridotomy immediately and further improved after the cessation of topiramate. While secondary angle closure glaucoma due to topiramate use has been widely reported, its effects in patients with underlying primary angle closure glaucoma have not been discussed. Our report highlights the importance of recognizing the often multifactorial etiology of angle closure glaucoma to help guide clinical management. Keywords: angle closure glaucoma, plateau iris, topiramate, secondary glaucoma, drug-induced glaucoma

  10. Experiencia multicéntrica colombiana durante tres años en el cierre percutáneo de la comunicación interventricular con diferentes dispositivos oclusores. Propuesta para la simplicación de la técnica en pacientes seleccionados Colombian multicentric experience during three years for percutaneous closure of interventricular septal defect with different occluder devices. Proposal for technique simplification in selected patients

    Directory of Open Access Journals (Sweden)

    Manuel R Téllez

    2010-09-01

    ,9% acusaron aparición o acentuación de episodios de cefalea vascular migrañosa. Hubo una complicación mayor dada por bloqueo atrioventricular completo y embolización del dispositivo. Conclusiones: el cierre endovascular de la comunicación interventricular es un procedimiento factible en nuestro medio, con el cual se alcanza un éxito cercano al 100%. El dispositivo para cierre de ductus de última generación puede implantarse con modificaciones en la técnica que aminora los tiempos de operatividad (hasta 60%, anestesia, utilización de medio de contraste y estancia hospitalaria. Por otra parte, su perfil hace posible el uso de sistemas de entregas 4 French que posibilitaría la inclusión de lactantes menores.Objectives: we describe the experience of the endovascular closure of interventricular communication performed for three years in different centers of interventional cardiology and highlight its result in a group of selected patients in whom such procedure was made by the use of a last generation device designed for the closure of ductus arteriosus. Methodology: between June 2006 and October 2009, a total of 34 patients underwent endovascular occlusion for interventricular septal defect. Indication of this procedure included volume overload, pressure and volume overload, chronic congestive heart failure, aortic valve prolapse with insufficiency and traumatic injury. Mean age was 12,9 years old and mean weight was 36 kg. A prevalence in male gender (53% was evidenced. Main blood flow calculation showed Qp / Qs of 1.71 to 1 and the pulmonary vascular resistance was 1.18 U Wood/m2. Materials and methods: PM VSD occluder device was implanted with the classic technique (62,5% while the Duct Occluder II (28,1% was used with the proposed simplified technique. General anesthesia was used in 98% cases; 60% were guided by fluoroscopy and transesophageal echocardiography and 40% with transthoracic echocardiography. Results: size of the defect varied from 4 to 12 mm. 91% of

  11. Closure of Microcosm for refurbishment

    CERN Multimedia

    2014-01-01

    Since 1994, the Microcosm exhibition has given the opportunity to visitors of all ages and backgrounds to have a first glimpse into the secrets of physics.   To ensure that Microcosm can continue fulfilling its educational aims at the same level of quality for many years to come, it is closing for renovation work on 8 December 2014 and is expected to reopen during Summer 2015. During the closure, the “Fun with Physics” workshop will not take place, but the Universe of Particles exhibition in the Globe and the Passport to the Big Bang circuit will remain accessible to the public, free of charge and with no need to book in advance.  Guided tours of CERN are also available (advance booking required via this page).

  12. Closure for milliliter scale bioreactor

    Science.gov (United States)

    Klein, David L.; Laidlaw, Robert D.; Andronaco, Gregory; Boyer, Stephen G.

    2010-12-14

    A closure for a microreactor includes a cap that is configured to be inserted into a well of the microreactor. The cap, or at least a portion of the cap, is compliant so as to form a seal with the well when the cap is inserted. The cap includes an aperture that provides an airway between the inside of the well to the external environment when the cap is inserted into the well. A porous plug is inserted in the aperture, e.g., either directly or in tube that extends through the aperture. The porous plug permits gas within the well to pass through the aperture while preventing liquids from passing through to reduce evaporation and preventing microbes from passing through to provide a sterile environment. A one-way valve may also be used to help control the environment in the well.

  13. Complications and mid-term outcome after percutaneous patent foramen ovale closure in patients with cryptogenic stroke

    Science.gov (United States)

    Luermans, J.G.L.M.; Post, M.C.; Plokker, H.W.M.; ten Berg, J.M.; Suttorp, M.J.

    2008-01-01

    Background: Percutaneous patent foramen ovale (PFO) closure seems to reduce the risk of recurrent thromboembolism. We report the safety and efficacy of percutaneous PFO closure in our centre. Methods: All patients, >16 years of age, who underwent a percutaneous PFO closure in our centre were included. Reoccurrence of stroke, transient ischaemic attack (TIA) and peripheral thromboembolism were assessed. Periprocedural and midterm complications are reported. Results: Eighty-three consecutive patients (mean age 49±13 years) were included. Indications for PFO closure were cryptogenic stroke (59.0%), TIA (33.7%), peripheral embolism (2.4%) and other (4.8%). For PFO closure, a Cardioseal/Starflex device was used in 63 patients and an Amplatzer PFO occluder device in 20 patients. Stroke recurred in 1.2%, TIA in 3.6%, peripheral embolism in 0% during a mean follow-up of 1.9±1.2 years. Major periprocedural complications occurred in 1.2%. The mid-term complication rate was 2.4% and only consisted of minor complications. During follow-up, a residual right-to-left shunt was present in 5.7% of the patients. No significant difference in outcome, complications or residual shunting could be documented between the two device types. Conclusion: In our centre, the percutaneous closure of a PFO seems to be a safe and effective procedure to prevent recurrence of paradoxical thrombo-embolic events. (Neth Heart J 2008;16:332-6.) PMID:18958256

  14. Preliminary experience using transthoracic echocardiography guiding percutaneous closure of ruptured right sinus of Valsalva aneurysm

    Institute of Scientific and Technical Information of China (English)

    LI Yue; WANG Guang-yi; WANG Zhi-feng; GUO Liang

    2011-01-01

    Background In the 21st century, minimally invasive treatment is one of the main developmental directions of medical sciences. It is well known that the echocardiography plays an important role during interventional treatments of some structural heart diseases. Because the ruptured right sinus of the Valsalva aneurysm (RRSVA) is a rare disease, there were few reports about percutaneous catheter closure of RRSVA. This study aimed to sum up our experience with transthoracic echocardiography (TTE) during percutaneous catheter closure of RRSVA.Methods Five RRSVA cases were treated with percutaneous catheter closure. The whole procedure was guided and monitored by TTE and fluoroscopy. The maximum diameter of the RRSVA was measured by TTE before and after the catheter passed through the rupture site. A duct occluder 2 mm larger than the maximum diameter was chosen. The closure effects were evaluated with TTE and fluoroscopy immediately after the occluding device was deployed. All patients were followed up by TTE for 8 to 30 months.Results Before the catheter passed through the rupture site the maximum diameter of the RRSVA measured with TTE and aortography were (7.9 ±2.1) mm and (7.8 ± 1.8) mm. After the catheter passed through the rupture site the maximum diameter measured with TTE was (11.2 ± 3.2) mm, which was significantly larger than before the procedure (P <0.05). The percutaneous catheter closure was successful in four cases and failed in one. Compared to the aortography the TTE was better at distinguishing residual shunts from aortic valve regurgitation immediately after the occluding device was deployed. There were no complications during 8 to 30 months of follow-up.Conclusion Transthoracic echocardiography can play an important role during percutaneous catheter closure of RRSVA,especially for estimating the size of the RRSVA after the catheter passes through the rupture site, and differentiating residual shunt from aortic valve regurgitation immediately

  15. Subsidence crack closure: rate, magnitude and sequence

    Energy Technology Data Exchange (ETDEWEB)

    De Graff, J.V.; Romesburg, H.C.

    1981-06-01

    Tension cracks are a major surface disturbance resulting from subsidence and differential settlement above underground coal mines. Recent engineering studies of subsidence indicate that cracks may close where tensile stresses causing the cracks are reduced or relaxed. This stress reduction occurs as mining in the area is completed. Crack closure was confirmed by a study in the Wasatch Plateau coal field of central Utah. Cracks occurred in both exposed bedrock and regolith in an area with maximum subsidence of 3 m. Mean closure rate was 0.3 cm per week with individual crack closure rates between 0.2 cm and 1.0 cm per week. The mean crack closure magnitude was 80% with closure magnitudes varying between 31% and 100%. Actual magnitude values ranged from 0.6 cm to 6.5 cm with a mean value of 3.8 cm. Statistical analysis compared width change status among cracks over time. It was found that: 1) a 41% probability existed that a crack would exhibit decreasing width per weekly measurement, 2) closure state sequences seem random over time, and 3) real differences in closure state sequence existed among different cracks. (6 refs.) (In English)

  16. Analytic closures for M1 neutrino transport

    Science.gov (United States)

    Murchikova, E. M.; Abdikamalov, E.; Urbatsch, T.

    2017-08-01

    Carefully accounting for neutrino transport is an essential component of many astrophysical studies. Solving the full transport equation is too expensive for most realistic applications, especially those involving multiple spatial dimensions. For such cases, resorting to approximations is often the only viable option for obtaining solutions. One such approximation, which recently became popular, is the M1 method. It utilizes the system of the lowest two moments of the transport equation and closes the system with an ad hoc closure relation. The accuracy of the M1 solution depends on the quality of the closure. Several closures have been proposed in the literature and have been used in various studies. We carry out an extensive study of these closures by comparing the results of M1 calculations with precise Monte Carlo calculations of the radiation field around spherically symmetric protoneutron star models. We find that no closure performs consistently better or worse than others in all cases. The level of accuracy that a given closure yields depends on the matter configuration, neutrino type and neutrino energy. Given this limitation, the maximum entropy closure by Minerbo on average yields relatively accurate results in the broadest set of cases considered in this work.

  17. Yucca Mountain Waste Package Closure System

    Energy Technology Data Exchange (ETDEWEB)

    shelton-davis; Colleen Shelton-Davis; Greg Housley

    2005-10-01

    The current disposal path for high-level waste is to place the material into secure waste packages that are inserted into a repository. The Idaho National Laboratory has been tasked with the development, design, and demonstration of the waste package closure system for the repository project. The closure system design includes welding three lids and a purge port cap, four methods of nondestructive examination, and evacuation and backfill of the waste package, all performed in a remote environment. A demonstration of the closure system will be performed with a full-scale waste package.

  18. Yucca Mountain Waste Package Closure System

    Energy Technology Data Exchange (ETDEWEB)

    Herschel Smartt; Arthur Watkins; David Pace; Rodney Bitsoi; Eric Larsen; Timothy McJunkin; Charles Tolle

    2006-04-01

    The current disposal path for high-level waste is to place the material into secure waste packages that are inserted into a repository. The Idaho National Laboratory has been tasked with the development, design, and demonstration of the waste package closure system for the repository project. The closure system design includes welding three lids and a purge port cap, four methods of nondestructive examination, and evacuation and backfill of the waste package, all performed in a remote environment. A demonstration of the closure system will be performed with a full-scale waste package.

  19. Effects of transcatheter closure of Fontan fenestration on exercise tolerance. kidecho@yahoo.com.

    Science.gov (United States)

    Momenah, Tarek S; Eltayb, Haifa; Oakley, Reida El; Qethamy, Howeida Al; Faraidi, Yahya Al

    2008-05-01

    Baffle fenestration is associated with a significantly better outcome in standard and high-risk patients undergoing completion of Fontan. We report the effects of subsequent transcatheter closure of fenestration on exercise capacity and oxygen saturation. Sixteen patients with a mean age of 10.3 years underwent Amplatzer septal occluder (ASO) device transcatheter closure of Fontan fenestration. All had a fenestrated Fontan operation 6 month to 8 years prior to the procedure. A stress test was performed before and after device closure of fenestration in 14 patients (2 patients did not tolerate stress test before the procedure). The fenestrations in all patients were successfully occluded with the use of the Amplatzer device occluder. No complications occurred during or after the procedure. O2 saturation increased from a mean 85.1 +/- 7.89% to 94.5 +/- 3.63% (p < 0.01) at rest and from 66.2 +/- 12.86% to 87.2 +/- 8.64% (p < 0.01) following exercise. Exercise duration has also increased from 8.22 +/- 2.74 min to 10.29 +/- 1.91 min (p < 0.05). Transcatheter closure of Fontan fenestration increases the duration of exercise capacity and increases O2 saturation at rest and after exercise.

  20. Thromboembolism Prevention via Transcatheter Left Atrial Appendage Closure with Transeosophageal Echocardiography Guidance

    Directory of Open Access Journals (Sweden)

    John Palios

    2014-01-01

    Full Text Available Atrial fibrillation (AF is an independent risk factor for stroke. Anticoagulation therapy has a risk of intracerebral hemorrhage. The use of percutaneous left atrial appendage (LAA closure devices is an alternative to anticoagulation therapy. Echocardiography has a leading role in LAA closure procedure in patient selection, during the procedure and during followup. A comprehensive echocardiography study is necessary preprocedural in order to identify all the lobes of the LAA, evaluate the size of the LAA ostium, look for thrombus or spontaneous echo contrast, and evaluate atrial anatomy, including atrial septal defect and patent foramen ovale. Echocardiography is used to identify potential cardiac sources of embolism, such as atrial septal aneurysm, mitral valve disease, and aortic debris. During the LAA occlusion procedure transeosophageal echocardiography provides guidance for the transeptal puncture and monitoring during the release of the closure device. Procedure-related complications can be evaluated and acceptable device release criteria such as proper position and seating of the occluder in the LAA, compression, and stability can be assessed. Postprocedural echocardiography is used for followup to assess the closure of the LAA ostium. This overview paper describes the emerging role of LAA occlusion procedure with transeosophageal echocardiography guidance as an alternative to anticoagulation therapy in patients with AF.

  1. Retrieval of embolized left atrial appendage devices.

    Science.gov (United States)

    Fahmy, Peter; Eng, Lim; Saw, Jacqueline

    2016-09-28

    Percutaneous left atrial appendage (LAA) closure is gaining interest as an alternative option for prevention of strokes in patients with Atrial Fibrillation (AF), especially for those with contraindications to anticoagulation. Complications from these procedures are well described in the medical literature. LAA closures may lead to pericardial effusion, device-associated thrombus, and device embolization. Understanding the reasons for embolization, strategies to avoid embolization, and the techniques for retrieval of LAA devices (ACP/AMULET and WATCHMAN) should be appreciated by endovascular implanters. We describe two cases of LAA device embolization that were both successfully retrieved percutaneously and other percutaneous techniques to safely retrieve embolized LAA devices. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  2. Systematization of a set of closure techniques.

    Science.gov (United States)

    Hausken, Kjell; Moxnes, John F

    2011-11-01

    Approximations in population dynamics are gaining popularity since stochastic models in large populations are time consuming even on a computer. Stochastic modeling causes an infinite set of ordinary differential equations for the moments. Closure models are useful since they recast this infinite set into a finite set of ordinary differential equations. This paper systematizes a set of closure approximations. We develop a system, which we call a power p closure of n moments, where 0≤p≤n. Keeling's (2000a,b) approximation with third order moments is shown to be an instantiation of this system which we call a power 3 closure of 3 moments. We present an epidemiological example and evaluate the system for third and fourth moments compared with Monte Carlo simulations.

  3. Entropy production and collisionless fluid closure

    Energy Technology Data Exchange (ETDEWEB)

    Sarazin, Y; Zarzoso, D; Garbet, X; Ghendrih, Ph; Grandgirard, V [CEA, IRFM, F-13108 Saint-Paul-lez-Durance (France); Dif-Pradalier, G, E-mail: yanick.sarazin@cea.f [Center for Astrophysics and Space Science, U.C.S.D., La Jolla, CA 92093 (United States)

    2009-11-15

    A novel method is proposed to construct collisionless fluid closures accounting for some kinetic properties. The idea consists in optimizing the agreement between the fluid and kinetic quasi-linear entropy production rates, so as to constrain the closure coefficients. This procedure is applied to the slab branch of the ion temperature gradient driven instability. Focusing on the kinetic regime characterized by slow waves, the closure proposed by Hammett and Perkins (Hammett and Perkins 1990 Phys. Rev. Lett. 64 3019) naturally emerges from the systematic identification of the kinetic and fluid entropy production rates. This closure is revealed to be extremely powerful well beyond the kinetic regime. Besides, it reconciles the fluid and kinetic linear stability diagrams in the two-dimensional space of the density and temperature gradient lengths. Such a method is systematic and generic. As such, it is applicable to other models and classes of instabilities.

  4. Entropy production and collisionless fluid closure

    Science.gov (United States)

    Sarazin, Y.; Dif-Pradalier, G.; Zarzoso, D.; Garbet, X.; Ghendrih, Ph; Grandgirard, V.

    2009-11-01

    A novel method is proposed to construct collisionless fluid closures accounting for some kinetic properties. The idea consists in optimizing the agreement between the fluid and kinetic quasi-linear entropy production rates, so as to constrain the closure coefficients. This procedure is applied to the slab branch of the ion temperature gradient driven instability. Focusing on the kinetic regime characterized by slow waves, the closure proposed by Hammett and Perkins (Hammett and Perkins 1990 Phys. Rev. Lett. 64 3019) naturally emerges from the systematic identification of the kinetic and fluid entropy production rates. This closure is revealed to be extremely powerful well beyond the kinetic regime. Besides, it reconciles the fluid and kinetic linear stability diagrams in the two-dimensional space of the density and temperature gradient lengths. Such a method is systematic and generic. As such, it is applicable to other models and classes of instabilities.

  5. Testing turbulent closure models with convection simulations

    CERN Document Server

    Snellman, J E; Mantere, M J; Rheinhardt, M; Dintrans, B

    2012-01-01

    Aims: To compare simple analytical closure models of turbulent Boussinesq convection for stellar applications with direct three-dimensional simulations both in homogeneous and inhomogeneous (bounded) setups. Methods: We use simple analytical closure models to compute the fluxes of angular momentum and heat as a function of rotation rate measured by the Taylor number. We also investigate cases with varying angles between the angular velocity and gravity vectors, corresponding to locating the computational domain at different latitudes ranging from the pole to the equator of the star. We perform three-dimensional numerical simulations in the same parameter regimes for comparison. The free parameters appearing in the closure models are calibrated by two fit methods using simulation data. Unique determination of the closure parameters is possible only in the non-rotating case and when the system is placed at the pole. In the other cases the fit procedures yield somewhat differing results. The quality of the closu...

  6. Reliability assessment of underground shaft closure

    Energy Technology Data Exchange (ETDEWEB)

    Fossum, A.F. [RE/SPEC, Inc., Rapid City, SD (United States); Munson, D.E. [Sandia National Labs., Albuquerque, NM (United States)

    1994-12-31

    The intent of the WIPP, being constructed in the bedded geologic salt deposits of Southeastern New Mexico, is to provide the technological basis for the safe disposal of radioactive Transuranic (TRU) wastes generated by the defense programs of the United States. In determining this technological basis, advanced reliability and structural analysis techniques are used to determine the probability of time-to-closure of a hypothetical underground shaft located in an argillaceous salt formation and filled with compacted crushed salt. Before being filled with crushed salt for sealing, the shaft provides access to an underground facility. Reliable closure of the shaft depends upon the sealing of the shaft through creep closure and recompaction of crushed backfill. Appropriate methods are demonstrated to calculate cumulative distribution functions of the closure based on laboratory determined random variable uncertainty in salt creep properties.

  7. Cyanoacrylate for Intraoral Wound Closure: A Possibility?

    Directory of Open Access Journals (Sweden)

    Parimala Sagar

    2015-01-01

    Full Text Available Wound closure is a part of any surgical procedure and the objective of laceration repair or incision closure is to approximate the edges of a wound so that natural healing process may occur. Over the years new biomaterials have been discovered as an alternate to conventional suture materials. Cyanoacrylate bioadhesives are one among them. They carry the advantages of rapid application, patient comfort, resistance to infection, hemostatic properties, and no suture removal anxiety. Hence this study was undertaken to study the effect of long chain cyanoacrylate as an adhesive for intraoral wound closure and also to explore its hemostatic and antibacterial effects. Isoamyl-2-cyanoacrylate (AMCRYLATE was used as the adhesive in the study. In conclusion isoamyl cyanoacrylate can be used for intraoral wound closure, as an alternative to sutures for gluing the mucoperiosteum to bone, for example, after impaction removal, periapical surgeries, and cleft repair. Its hemostatic and antibacterial activity has to be further evaluated.

  8. [Percutaneous closure of patent ductus arteriosus: results and costs compared to surgical closure].

    Science.gov (United States)

    Vieu, T; Beaurain, S; Angel, C; Leriche, H; Petit, J; Conso, J F; Planché, C; Losay, J

    1995-10-01

    The comparison of the clinical results and costs of the two methods of closure of patient ductus arteriosus was undertaken in two comparable groups of 40 patients treated in the same period in the same hospital. After transcatheter closure there was a 9% residual shunt rate at 3 years, the 2 patients with a residual continuous murmur being operated secondarily. The only complication was severe haemolysis which regressed after transcatheter ablation of the prosthesis. After surgical closure, there were no residual shunt. Some postoperative complications were observed in 20% of cases, usually benign (ventilatory problems, dysphonia or urinary infection), but occasionally more serious (peroperative lesion of the pulmonary artery). Morbidity, inherent to the technique of closure, was very different and much less in catheter closure. The average cost (daily cost x average length of hospital stay) was much less with transcatheter closure 38,558 francs versus 11,240 francs. On the other hand, the direct cost of transcatheter closure was greater than that of surgery: 32,798 francs versus 20,903 francs, the difference being related to the actual price of the prosthesis. The authors conclude that the 3 year results of transcatheter closure of patent ductus arterious make this technique a reasonable therapeutic alternative to surgery. From the safety point of view, the two techniques are comparable bu patient confort is greater with transcatheter closure for an increase in cost of the initial procedure which should decrease in relation to the types and prices of the prosthesis used.

  9. Primary closure for postoperative mediastinitis in children.

    Science.gov (United States)

    Ohye, Richard G; Maniker, Robert B; Graves, Holly L; Devaney, Eric J; Bove, Edward L

    2004-09-01

    Mediastinitis affects approximately 1% of children undergoing median sternotomy. Conventional therapy involves debridement followed by open wound care with delayed closure, days to weeks of closed suction or antimicrobial irrigation, and vacuum-assisted closure or muscle flap closure. We hypothesized that primary closure without prolonged suction or irrigation is an effective, less traumatic treatment for mediastinitis in children. From January 1986 to July 2002, 6705 procedures involving median sternotomy were performed at the C. S. Mott Children's Hospital, resulting in 57 cases of mediastinitis (0.85%). Cases were divided into 2 groups, with 42 cases treated with primary closure and 15 cases treated with delayed or muscle flap closure. The 42 cases of primary closure comprised the primary study group of this institutional review board-approved, retrospective analysis. Patient demographics, surgical variables, mediastinitis-related parameters, and outcomes were evaluated. One patient had recurrent mediastinitis for an overall infection eradication rate of 97% (40/41). Three patients (7%) required re-exploration for suspected ongoing infection. Of these re-explorations, 1 patient had evidence of continued mediastinitis. The remaining 2 patients with sepsis of unclear cause had no clinical or culture evidence of recurrent infection. One of these patients ultimately died of sepsis without active mediastinitis for a hospital survival of 97% (41/42). No significant differences could be detected between the treatment successes and failures in this small cohort of patients. Simple primary closure is an effective means to treat selected cases of postoperative mediastinitis in children. The results compare favorably with other more lengthy or debilitating treatments.

  10. Exceptional closure of UNIQA office at CERN

    CERN Multimedia

    HR Department

    2009-01-01

    The UNIQA office at CERN will be closed from Wednesday 18 February to Friday 20 February due to painting work. During this closure, the Headquarters of UNIQA in Geneva will remain at the disposal of the members. See details https://cern.ch/chis/UNIQA_Offices.asp The CERN office will re-open on Monday 23 February according to the normal schedule. We apologise for any inconvenience caused by this closure.

  11. Fenestrated Transcatheter ASD Closure in Adults with Diastolic Dysfunction and/or Pulmonary Hypertension: Case Series and Review of the Literature.

    Science.gov (United States)

    Abdelkarim, Ayman; Levi, Daniel S; Tran, Bao; Ghobrial, Joanna; Aboulhosn, Jamil

    2016-12-01

    This study aims to evaluate the safety and efficacy of transcatheter fenestrated ASD closure and to summarize the literature regarding the published techniques and outcomes of transcatheter partial ASD closure. Patients with left ventricular diastolic dysfunction (LVDD) or right ventricular (RV) dysfunction and/or pulmonary hypertension (PHT) may suffer untoward consequences of complete closure of an ostium secundum atrial septal defect (ASD). Therefore, for patients that fall under these categories we suggest partial occlusion of the defect, which may be better tolerated than complete defect closure. After obtaining IRB approval, a search for patients that have undergone percutaneous ASD closure was performed in the Ahmanson/UCLA Adult Congenital Heart Disease Center database to identify which patients received a fenestrated ASD closure device. Eight consecutive patients ranging between 22 and 83 years of age (mean 48 years) with PHT and/or LVDD or RV dysfunction who underwent fenestrated transcatheter ASD closure at UCLA were identified. None of the subjects experienced complications related to the procedure. Postprocedure clinical evaluation showed improvement in symptoms and exercise capacity. Available follow-up transthoracic echocardiography data (mean 4 months, range 0-20 months) demonstrated patent fenestrations in four of eight patients. None of the patients had thromboembolic or infectious complications and there were no device migrations, erosions or embolizations. Partial ASD occlusion in patients with diastolic dysfunction or RV dysfunction and/or PHT is safe and may be better tolerated than complete ASD closure in selected patients. © 2016 Wiley Periodicals, Inc.

  12. Risk and fate of residual interatrial shunting after transcatheter closure of patent foramen ovale: a long term follow up study

    Directory of Open Access Journals (Sweden)

    Hammerstingl C

    2011-01-01

    Full Text Available Abstract Background Percutaneous transcatheter closure of patent foramen ovale (PFO in cryptogenic stroke is an alternative to medical therapy. There is still debate on different outcome for each currently available device. The impact of residual shunting after PFO-clo- sure on recurrent arterial embolism is unknown. Aims (i To evaluate the prevalence of residual interatrial shunting after device- closure of PFO, (ii to identify risk factors predicting residual interatrial shunting after device implantation, and (iii to investigate the outcome of patients after PFO-closure during long- term follow- up (FU. Methods and results Between 2000- 2005 PFO-closure was performed in 124 patients using four different devices: Amplatzer PFO-(n = 52, CardioSeal (n = 33, Helex (n = 23 and Premere (n = 16 occluder. All patients underwent serial contrast-enhanced transesophageal echocardiography (TEE for 24 months after PFO- closure; clinical FU was at minimum 5 years up to 9.75 years (mean 6.67 ± 1.31 years. Overall-closure rate was 87% at 2 years, device-specific closure time curves differed significantly (p-logrank = 0.003. Independent risk factors for residual-shunting were implantation of a Helex occluder (hazard ratio [HR] 12.6, 95% confidence interval [CI] 2.6- 57.4, p = 0.002, PFO- canal- lengths (HR 1.2, 95%CI 1.1- 1.3, p = 0.004 and extend of atrial-septal-aneurysm (HR 1.1, 95%CI 0.9- 1.3; p = 0.05. 4 (3.2% arterial embolic events occurred during a FU-period of 817.2 patient-years, actuarial annual thromboembolic-risk was 0.49%. All ischemic events were not related to residual PFO-shunting or device-related thrombus- formation. Conclusion Success rates of PFO- closure are mainly dependent on occluder-type, extend of concomitant atrial-septum-aneurysm and PFO-canal- length. Importantly, residual shunting after PFO-closure was not associated with recurrence of arterial embolism during long-term follow-up.

  13. 105-DR Large Sodium Fire Facility closure activities evaluation report

    Energy Technology Data Exchange (ETDEWEB)

    Adler, J.G.

    1996-04-22

    This report evaluates the closure activities at the 105-DR Large Sodium Fire Facility. The closure activities discussed include: the closure activities for the structures, equipment, soil, and gravel scrubber; decontamination methods; materials made available for recycling or reuse; and waste management. The evaluation compares these activities to the regulatory requirements and closure plan requirements. The report concludes that the areas identified in the closure plan can be clean closed.

  14. NPAR- products, applications and closure

    Energy Technology Data Exchange (ETDEWEB)

    Vora, J.P.

    1995-04-01

    Almost a decade ago the Office of Nuclear Regulatory Research (RES) developed and implemented a comprehensive research program (NUREG-1144) widely known as NPAR or Nuclear Plant Aging Research. The NPAR program is a structured research program specifically oriented to understanding significant age-related degradation mechanisms and their long term effects on properties and performance of important components and systems and ways to mitigate detrimental effects of aging. It provided a road map and a phased approach to research that is applicable to any structure, system, or component of interest. This hardware-oriented engineering research program led the industry worldwide and communicated a need to understand and manage age-related degradation effects in selected but important structures and components. At the conclusion (1995) of the NPAR program, 22 electrical and mechanical components, 13 safety-related systems, and 10 special topics will have been studied and results summarized in 160 technical reports. This reference library of information listed and summarized in NUREG-1377, Rev. No. 4 provides a foundation upon which individual programs can be built for the specific needs of a utility, a regulator, or equipment manufacturers. During the life of the NPAR program, it has provided technical bases and support for license renewal, codes and standards, resolution of generic safety issues, information notices, regulatory guides and the standard Review Plan, as well as the Office of Nuclear Reactor Regulation and The NRC Regions. All ongoing NPAR activities will either be completed or terminated by the end of 1995. No new initiative will be undertaken. This paper summarizes NPAR products and accomplishments, application of the research results, and its status and closure.

  15. Accelerating cleanup: Paths to closure

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-06-01

    This report describes the status of Environmental Management`s (EM`s) cleanup program and a direction forward to complete achievement of the 2006 vision. Achieving the 2006 vision results in significant benefits related to accomplishing EM program objectives. As DOE sites accelerate cleanup activities, risks to public health, the environment, and worker safety and health are all reduced. Finding more efficient ways to conduct work can result in making compliance with applicable environmental requirements easier to achieve. Finally, as cleanup activities at sites are completed, the EM program can focus attention and resources on the small number of sites with more complex cleanup challenges. Chapter 1 describes the process by which this report has been developed and what it hopes to accomplish, its relationship to the EM decision-making process, and a general background of the EM mission and program. Chapter 2 describes how the site-by-site projections were constructed, and summarizes, for each of DOE`s 11 Operations/Field Offices, the projected costs and schedules for completing the cleanup mission. Chapter 3 presents summaries of the detailed cleanup projections from three of the 11 Operations/Field Offices: Rocky Flats (Colorado), Richland (Washington), and Savannah River (South Carolina). The remaining eight Operations/Field Office summaries are in Appendix E. Chapter 4 reviews the cost drivers, budgetary constraints, and performance enhancements underlying the detailed analysis of the 353 projects that comprise EM`s accelerated cleanup and closure effort. Chapter 5 describes a management system to support the EM program. Chapter 6 provides responses to the general comments received on the February draft of this document.

  16. Monte Carlo simulation for thermal assisted reversal process of micro-magnetic torus ring with bistable closure domain structure

    Energy Technology Data Exchange (ETDEWEB)

    Terashima, Kenichi; Suzuki, Kenji; Yamaguchi, Katsuhiko, E-mail: yama@sss.fukushima-u.ac.jp

    2016-04-01

    Monte Carlo simulations were performed for temperature dependences of closure domain parameter for a magnetic micro-torus ring cluster under magnetic field on limited temperature regions. Simulation results show that magnetic field on tiny limited temperature region can reverse magnetic closure domain structures when the magnetic field is applied at a threshold temperature corresponding to intensity of applied magnetic field. This is one of thermally assisted switching phenomena through a self-organization process. The results show the way to find non-wasteful pairs between intensity of magnetic field and temperature region for reversing closure domain structure by temperature dependence of the fluctuation of closure domain parameter. Monte Carlo method for this simulation is very valuable to optimize the design of thermally assisted switching devices.

  17. Outcomes of Clinical Application of Boomerang Closure Wire System

    Institute of Scientific and Technical Information of China (English)

    Jian-sheng WU; Wen-bin WEI; Yu-jia WANG; Xin-xia ZHANG; Xue-song HU

    2009-01-01

    Objectives To evaluate the efficacy and safety of clinical application of a novel type of vascular closure device named Boomerang closure wire system (BCWS). Methods BCWSs were used in 288 patients (BCWSs group) for hemostasis after transfernoral coronary angiography (CAG) or percutaneous coronary intervention (PCI). Device suc-cess rate, hemostasis success rate, manual compression time, recumbent time, minor peripheral complication rate, se-vere peripheral complication rate and hospital staying time after procedure were analyzed. Results were compared to those from 300 patients (control group) who received manual compression in our hospital during the same period. Results In BCWS group, device success rate was 97.2 %, hemostasis success rate was 95.1%. Manual compression time in CAG subgroup and PCI subgroup was 7.8 min and 11.2 min, respectively. Recumbent time was 136. 3 min in CAG subgroup, 284.6 min in PCI subgroup. Minor peripheral complication rate was 4.5 %, severe peripheral compli-cation rate was 2.4 %. Hospital-staying time after procedure in CAG group and PCI group was 1.8 d and 6.6 d, re-spectively. Compared to control group, manual compression time, recumbent time and hospital-staying time of BCWSs group had statistical significance; hemostasis success rate, minor peripheral complication rate and severe peripheral complication rate of BCWSs group bad no statistical difference. Conclusions BCWS provides satisfied haemostatic effect. Compared to routine manual compression, BCWS shortens manual compression time, recumbent time and hos-pital staying time.

  18. An eddy closure for potential vorticity

    Energy Technology Data Exchange (ETDEWEB)

    Ringler, Todd D [Los Alamos National Laboratory

    2009-01-01

    The Gent-McWilliams (GM) parameterization is extended to include a direct influence in the momentum equation. The extension is carried out in two stages; an analysis of the inviscid system is followed by an analysis of the viscous system. In the inviscid analysis the momentum equation is modified such that potential vorticity is conserved along particle trajectories following a transport velocity that includes the Bolus velocity in a manner exactly analogous to the continuity and tracer equations. In addition (and in contrast to traditional GM closures), the new formulation of the inviscid momentum equation results in a conservative exchange between potential and kinetic forms of energy. The inviscid form of the eddy closure conserves total energy to within an error proportional to the time derivative of the Bolus velocity. The hypothesis that the viscous term in the momentum equation should give rise to potential vorticity being diffused along isopycnals in a manner analogous to other tracers is examined in detail. While the form of the momentum closure that follows from a strict adherence to this hypothesis is not immediately interpretable within the constructs of traditional momentum closures, three approximations to this hypothesis results in a form of dissipation that is consistent with traditional Laplacian diffusion. The first two approximations are that relative vorticity, not potential vorticity, is diffused along isopyncals and that the flow is in approximate geostrophic balance. An additional approximation to the Jacobian term is required when the dissipation coefficient varies in space. More importantly, the critique of this hypothesis results in the conclusion that the viscosity parameter in the momentum equation should be identical to the tradition GM closure parameter {Kappa}. Overall, we deem the viscous form of the eddy closure for potential vorticity as a viable closure for use in ocean circulation models.

  19. Immediate and mid-term clinical course after percutaneous closure of paravalvular leakage.

    Science.gov (United States)

    Sánchez-Recalde, Angel; Moreno, Raúl; Galeote, Guillermo; Jimenez-Valero, Santiago; Calvo, Luis; Sevillano, Joel Hernández; Arroyo-Ucar, Eduardo; López, Teresa; Mesa, José M; López-Sendón, José L

    2014-08-01

    Percutaneous closure of paravalvular leakage is an alternative to surgery in high-risk patients, but its use has been limited by a lack of specific devices. More appropriate devices-like the Amplatzer Vascular Plug III-have recently been developed, but information about their efficacy and safety is still scarce. The objective of the present study was to assess the mid-term results of paravalvular leakage closure with this device. We analyzed the clinical and echocardiographic course both in-hospital and mid-term (13 [9] months) in a series of 20 consecutive patients (age, 68 years; logistic EuroSCORE, 29) with paravalvular leakage and attempted percutaneous closure. Closure was attempted for 23 leaks (17 mitral and 6 aortic) during 22 procedures in 20 patients. Implantation was successful in 87% of the leaks and the procedure was successful in 83%-with success being defined as a reduction in regurgitation of ≥ 1 degree. Survival at 1 year was 64.7% and survival free of the composite event of death/surgery was 58.8%. The degree of residual regurgitation was not associated with mortality but was associated with functional status. Survivors showed significant improvement in functional class. Percutaneous closure of leakage with the Amplatzer Vascular Plug III is safe and efficient in the mid-term. However, mortality among high-risk patients is high independently of the degree of residual regurgitation, indicating that these procedures are performed when heart disease has reached an advanced stage. Copyright © 2014 Sociedad Española de Cardiología. Published by Elsevier Espana. All rights reserved.

  20. Transcatheter closure of secundum atrial septal defect using an Amplatzer septal occluder

    Institute of Scientific and Technical Information of China (English)

    孔祥清; 曹克将; 杨荣; 许迪; 盛燕辉; 黄峻; 马文珠

    2002-01-01

    Objective To evaluate the safety and efficacy of the Amplatzer septal occluder for transcatheter closure in patients with secundum atrial septal defect (ASD Ⅱ). Methods Patients with clinically confirmed ASD Ⅱ were recommended for transcatheter closure of ASD Ⅱ. Results 30 ASD Ⅱ patients (20 females) underwent transcatheter closure at a median age of 18.4 years (5-55 years). Both the stretched diameters of ASDs and the sizes of the devices were from 18 to 34?mm (25±7?mm). The successful placement rate was 100%. The rest shunt documented by color Doppler, was immediately after implantation in 40% of patients, in 9.9% after 24 hours, and in 3.3% trace at 3 months. No serious complications were observed. There was improvement in symptoms and in cardiac size. Septal motion abnormalities normalized in all patients after 3 months follow-up. Conclusion The Amplatzer septal occluder is a safe and effective device for transcatheter closure of ASD Ⅱ. Long-term follow-up is still required before widespread clinical use can be recommended.

  1. The clinical effect of Ex-Press glaucoma drainage device implantation combined with phacoemulsification for primary acute angle-closure glaucoma with cataract and persistent ocular hypertension%持续高眼压下白内障青光眼联合手术中青光眼引流器的应用

    Institute of Scientific and Technical Information of China (English)

    刘杰

    2015-01-01

    目的 探讨Ex-Press青光眼引流器植入联合晶状体超声乳化吸出术治疗合并白内障的急性闭角型青光眼持续高眼压患者的临床效果和安全性.方法 回顾性分析26例(30只眼)行Ex-Press青光眼引流器植入联合超声乳化手术治疗的合并白内障的急性闭角型青光眼持续性高眼压患者术前及术后各时间段的视力、眼压及并发症发生情况.结果 所有患者均随访至1年,完全成功率为76.67%(23只眼),部分成功率23.33%(7只眼),总成功率100.00%.术前平均眼压为(32.19±9.12) mmHg(1 mmHg=0.133kPa).术后1周,1、2、3、6及12个月的平均眼压分别为(10.30±5.07) mmHg、(10.28±4.93) mmHg、(10.87±4.22) mmHg、(11.32±6.11) mmHg、(12.12 ±6.07)mmHg、(13.05±5.26)mmHg,手术后眼压均较术前低,差异有统计学意义(P<0.05).术后1周视力较术前提高,差异有统计学意义(Z=-4.19,P=0.000).30只眼中2只眼出现少量前房积血,分别于术后4~7d吸收;4只眼出现一过性低眼压,8~10 d后眼压>6 mmHg;1只眼出现渗出性脉络膜脱离,于术后14 d复位.所有患者均未出现其他并发症.结论 Ex-Press青光眼引流器植入联合晶状体超声乳化吸出术是治疗合并白内障的急性闭角型青光眼持续性高眼压的一种安全而有效的方法.%Objective To investigate the clinical effects and safety of Ex-Press glaucoma drainage device implantation combined with phacoemulsification (E-P P) for primary acute angle-closure glaucoma (PAACG) with cataract and persistent ocular hypertension.Methods The data of 30 eyes of 26 patients of PAACG with cataract and persistent ocular hypertension were retrospectively analyzed, who received E-P P surgery.The visual acuity,intraocular pressure (IOP) and complications were observed.Results All patients were followed up for 1 year.The complete success rate was 76.67% (23 eyes), the partial success rate was 23.33% (7 eyes), and the total success rate was 100

  2. PHASE CLOSURE NULLING: THEORY AND PRACTICE

    Directory of Open Access Journals (Sweden)

    A. Chelli

    2009-01-01

    Full Text Available We provide a complete theory of the phase closure of a binary system in which a small, feeble, and unresolved companion acts as a perturbing parameter on the spatial frequency spectrum of a dominant, bright, resolved source. We demonstrate that the in uence of the companion can be measured with precision by measuring the phase closure of the system near the nulls of the primary visibility function. In these regions of phase closure nulling, frequency intervals always exist where the phase closure signature of the companion is larger than any systematic error and can thus be measured. We show that this technique allows retrieval of many astrophysically relevant properties of faint and close companions such as ux, position, and in favorable cases, spectrum. As a proof of concept, using the AMBER/VLTI instrument with 3 auxiliary telescopes of 1.8 m and only 15 minutes of on-sky integration, we detected the ve magnitudes fainter companion of HD 59717 at only 3.5 stellar radii distance from the primary. This is one of the highest contrast detected by interferometry between a companion and its parent star. We conclude by a rapid study of the potentialities of phase closure nulling observations with current interferometers and explore the requirements for a new type of dedicated instrument.

  3. Space Station evolution study oxygen loop closure

    Science.gov (United States)

    Wood, M. G.; Delong, D.

    1993-01-01

    In the current Space Station Freedom (SSF) Permanently Manned Configuration (PMC), physical scars for closing the oxygen loop by the addition of oxygen generation and carbon dioxide reduction hardware are not included. During station restructuring, the capability for oxygen loop closure was deferred to the B-modules. As such, the ability to close the oxygen loop in the U.S. Laboratory module (LAB A) and the Habitation A module (HAB A) is contingent on the presence of the B modules. To base oxygen loop closure of SSF on the funding of the B-modules may not be desirable. Therefore, this study was requested to evaluate the necessary hooks and scars in the A-modules to facilitate closure of the oxygen loop at or subsequent to PMC. The study defines the scars for oxygen loop closure with impacts to cost, weight and volume and assesses the effects of byproduct venting. In addition, the recommended scenarios for closure with regard to topology and packaging are presented.

  4. Tulip deformity with Cera atrial septal defect devices: a report of 3 cases.

    Science.gov (United States)

    Kohli, Vikas

    2015-02-01

    Device closure of secundum atrial septal defect (ASD) is the treatment of choice when anatomy is favourable. Amplatzer device has remained the gold standard for closure of ASD. Cobra deformity is a well-reported problem with devices. Recently, Tulip deformity has been reported in a single case. We report a series of cases where we noted Tulip deformity along with inability to retract the device in the sheath in Cera Lifetech devices. This resulted in prolongation of procedure, excessive fluoroscopic exposure and additional interventional procedures not usually anticipated in ASD device closure. We believe that the problem is due to the stiffness of the device resulting in its inability to be retracted into the sheath. We also report a unique way of retrieving the device.

  5. Median sternotomy closure: review and update research

    Institute of Scientific and Technical Information of China (English)

    Hua Kun; Yang Xiubin

    2009-01-01

    Cardiac surgery is a very common operation nowadays all over the world. Median stemotomy is a routine procedure required for cardiac access during open heart surgery. The complications of this procedure after the cardiac surgery range from 0.7% to 1.5% of all cases, and bear a high mortality rate if they occur. Every individual surgeon must pay great attention on every detail during the sternal closure. This article shows the details as to conventional information and updated progress on median sternotomy closure. The update contents involve in biomechanics, number of wires twists, biomaterial and so on.According to our experience, we recommend four peristernal single/double steel wires for sternal closure as our optimal choice.

  6. Biological constraints do not entail cognitive closure.

    Science.gov (United States)

    Vlerick, Michael

    2014-12-01

    From the premise that our biology imposes cognitive constraints on our epistemic activities, a series of prominent authors--most notably Fodor, Chomsky and McGinn--have argued that we are cognitively closed to certain aspects and properties of the world. Cognitive constraints, they argue, entail cognitive closure. I argue that this is not the case. More precisely, I detect two unwarranted conflations at the core of arguments deriving closure from constraints. The first is a conflation of what I will refer to as 'representation' and 'object of representation'. The second confuses the cognitive scope of the assisted mind for that of the unassisted mind. Cognitive closure, I conclude, cannot be established from pointing out the (uncontroversial) existence of cognitive constraints.

  7. Hanford Patrol Academy demolition sites closure plan

    Energy Technology Data Exchange (ETDEWEB)

    1993-09-30

    The Hanford Site is owned by the U.S. Government and operated by the U.S. Department of Energy, Richland Operations Office. Westinghouse Hanford Company is a major contractor to the U.S. Department of Energy, Richland Operations Office and serves as co-operator of the Hanford Patrol Academy Demolition Sites, the unit addressed in this paper. This document consists of a Hanford Facility Dangerous Waste Part A Permit Application, Form 3 (Revision 4), and a closure plan for the site. An explanation of the Part A Form 3 submitted with this closure plan is provided at the beginning of the Part A section. This Hanford Patrol Academy Demolition Sites Closure Plan submittal contains information current as of December 15, 1994.

  8. Adapting MARSSIM for FUSRAP site closure.

    Science.gov (United States)

    Johnson, Robert; Durham, L; Rieman, C

    2003-06-01

    The Multi-Agency Radiation Survey and Site Investigation Manual (MARSSIM) provides a coherent, technically defensible process for establishing that exposed surfaces satisfy site cleanup requirements. Unfortunately, many sites have complications that challenge a direct application of MARSSIM. Example complications include Record of Decision (ROD) requirements that are not MARSSIM-friendly, the potential for subsurface contamination, and incomplete characterization information. These types of complications are typically the rule, rather than the exception, for sites undergoing radiologically-driven remediation and closure. One such site is the Formerly Utilized Sites Remedial Action Program (FUSRAP) Linde site in Tonawanda, New York. Cleanup of the site is currently underway. The Linde site presented a number of challenges to designing and implementing a closure strategy consistent with MARSSIM. This paper discusses some of the closure issues confronted by the U.S. Army Corps of Engineers Buffalo District at the Linde site and describes how MARSSIM protocols were adapted to address these issues.

  9. 2401-W Waste storage building closure plan

    Energy Technology Data Exchange (ETDEWEB)

    LUKE, S.M.

    1999-07-15

    This plan describes the performance standards met and closure activities conducted to achieve clean closure of the 2401-W Waste Storage Building (2401-W) (Figure I). In August 1998, after the last waste container was removed from 2401-W, the U.S. Department of Energy, Richland Operations Office (DOE-RL) notified Washington State Department of Ecology (Ecology) in writing that the 2401-W would no longer receive waste and would be closed as a Resource Conservation and Recovery Act (RCRA) of 1976 treatment, storage, and/or disposal (TSD) unit (98-EAP-475). Pursuant to this notification, closure activities were conducted, as described in this plan, in accordance with Washington Administrative Code (WAC) 173-303-610 and completed on February 9, 1999. Ecology witnessed the closure activities. Consistent with clean closure, no postclosure activities will be necessary. Because 2401-W is a portion of the Central Waste Complex (CWC), these closure activities become the basis for removing this building from the CWC TSD unit boundary. The 2401-W is a pre-engineered steel building with a sealed concrete floor and a 15.2-centimeter concrete curb around the perimeter of the floor. This building operated from April 1988 until August 1998 storing non-liquid containerized mixed waste. All waste storage occurred indoors. No potential existed for 2401-W operations to have impacted soil. A review of operating records and interviews with cognizant operations personnel indicated that no waste spills occurred in this building (Appendix A). After all waste containers were removed, a radiation survey of the 2401-W floor for radiological release of the building was performed December 17, 1998, which identified no radiological contamination (Appendix B).

  10. Final Clean Closure Report Site 300 Surface Impoundments Closure Lawrence Livermore National Laboratory Livermore, California

    Energy Technology Data Exchange (ETDEWEB)

    Haskell, K

    2006-02-14

    Lawrence Livermore National Laboratory operated two Class II surface impoundments that stored wastewater that was discharged from a number of buildings located on the Site 300 Facility (Site 300). The wastewater was the by-product of explosives processing. Reduction in the volume of water discharged from these buildings over the past several years significantly reduced the wastewater storage needs. In addition, the impoundments were constructed in 1984, and the high-density polyethylene (HDPE) geomembrane liners were nearing the end of their service life. The purpose of this project was to clean close the surface impoundments and provide new wastewater storage using above ground storage tanks at six locations. The tanks were installed and put into service prior to closure of the impoundments. This Clean Closure Report (Closure Report) complies with State Water Resources Control Board (SWRCB) Section 21400 of the California Code of Regulations Title 27 (27 CCR section 21400). As required by these regulations and guidance, this Closure Report provides the following information: (1) a brief site description; (2) the regulatory requirements relevant to clean closure of the impoundments; (3) the closure procedures; and (4) the findings and documentation of clean closure.

  11. Closure properties of Watson-Crick grammars

    Science.gov (United States)

    Zulkufli, Nurul Liyana binti Mohamad; Turaev, Sherzod; Tamrin, Mohd Izzuddin Mohd; Azeddine, Messikh

    2015-12-01

    In this paper, we define Watson-Crick context-free grammars, as an extension of Watson-Crick regular grammars and Watson-Crick linear grammars with context-free grammar rules. We show the relation of Watson-Crick (regular and linear) grammars to the sticker systems, and study some of the important closure properties of the Watson-Crick grammars. We establish that the Watson-Crick regular grammars are closed under almost all of the main closure operations, while the differences between other Watson-Crick grammars with their corresponding Chomsky grammars depend on the computational power of the Watson-Crick grammars which still need to be studied.

  12. The effect of plant closure on crime

    OpenAIRE

    Rege, Mari; Skarðhamar, Torbjørn; Telle, Kjetil; Votruba, Mark

    2009-01-01

    We estimate the effect of exposure to plant closure on crime using an individual-level panel data set containing criminal charges for all unmarried and employed Norwegian men below the age of 40. Men originally employed in plants that subsequently closed are 14 percent more likely to be charged of a crime than comparable men in stable plants. There is no difference in charge rates prior to closure, supporting a causal interpretation of our result. Within crime categories, we find no effect of...

  13. Straight line closure of congenital macrostomia

    Directory of Open Access Journals (Sweden)

    Schwarz Richard

    2004-01-01

    Full Text Available The results of patients operated on by Nepal Cleft Lip and Palate Association (NECLAPA surgeons for congenital macrostomia were prospectively studied between January 2000 and December 2002. There were four males and three females with a median age of 10 years. Three had an associated branchial arch syndrome. In all patients an overlapping repair of orbicularis oris was done. Six patients had a straight line closure with excellent cosmetic results and one a Z-plasty with a more obvious scar. All had a normal appearing commissure. Overlapping orbicularis repair with straight line skin closure for this rare congenital anomaly is recommended.

  14. Surgical repair of tricuspid valve leaflet tear following percutaneous closure of perimembranous ventricular septal defect using Amplatzer duct occluder I: Report of two cases

    Directory of Open Access Journals (Sweden)

    Saatchi Mahesh Kuwelker

    2017-01-01

    Full Text Available Tricuspid valve (TV injury following transcatheter closure of perimembranous ventricular septal defect (PMVSD with Amplatzer ductal occluder I (ADO I, requiring surgical repair, is rare. We report two cases of TV tear involving the anterior and septal leaflets following PMVSD closure using ADO I. In both the patients, the subvalvular apparatus remained unaffected. The patients presented with severe tricuspid regurgitation (TR 6 weeks and 3 months following the device closure. They underwent surgical repair with patch augmentation of the TV leaflets. Postoperatively, both are asymptomatic with a mild residual TR.

  15. Surgical repair of tricuspid valve leaflet tear following percutaneous closure of perimembranous ventricular septal defect using Amplatzer duct occluder I: Report of two cases

    Science.gov (United States)

    Kuwelker, Saatchi Mahesh; Shetty, Devi Prasad; Dalvi, Bharat

    2017-01-01

    Tricuspid valve (TV) injury following transcatheter closure of perimembranous ventricular septal defect (PMVSD) with Amplatzer ductal occluder I (ADO I), requiring surgical repair, is rare. We report two cases of TV tear involving the anterior and septal leaflets following PMVSD closure using ADO I. In both the patients, the subvalvular apparatus remained unaffected. The patients presented with severe tricuspid regurgitation (TR) 6 weeks and 3 months following the device closure. They underwent surgical repair with patch augmentation of the TV leaflets. Postoperatively, both are asymptomatic with a mild residual TR. PMID:28163430

  16. Conscious sedation using dexmedetomidine for percutaneous transcatheter closure of atrial septal defects: A single center experience

    Directory of Open Access Journals (Sweden)

    Pushkar Mahendra Desai

    2016-01-01

    Full Text Available Objective: The aim of this study is to determine safety and feasibility of conscious sedation using dexmedetomidine for transcatheter atrial septal defect (ASD device closure. Material and Methods: A retrospective institutional review of transcatheter ASD device closure without endotracheal intubation over 18 months. The protocol included topical oropharyngeal anesthesia using lignocaine followed by dexmedetomidine bolus 1 μg/kg intravenously over 10 min and maintenance dose 0.2-0.7 μg/kg/h. Ramsay sedation score 2-3 was maintained. Patients were analyzed regarding demographic profile, device size, procedure time, anesthesia time, recovery time, hospital stay, and any hemodynamic or procedural complications. Results: A total of 43 patients with mean age 31.56 ± 13.74 years (range: 12-56 years were analyzed. Mean anesthesia duration was 71.75 + 21.08 min. Mean recovery time was 7.6 ± 3.01 min. 16 females and one male patient required additional propofol with a mean dose of 30.8 ± 10.49 mg. No hemodynamic instability was noted. No patient required general anesthesia with endotracheal intubation. The procedure was successful in 93.02% of patients. Four patients developed atrial fibrillation. All patients were satisfied. Conclusion: Conscious sedation using dexmedetomidine is a safe and effective anesthetic technique for percutaneous ASD closure.

  17. Interventional Closure of Patent Foramen Ovale (PFO with Amplatzer PFO Occluder in Patients with Paradoxical Cerebral Embolism

    Directory of Open Access Journals (Sweden)

    Ali Mohammad Haji Zeinali

    2006-08-01

    Full Text Available Background: Percutaneous transcatheter closure has been proposed as an alternative to surgical closure or long-term anticoagulation in patients with presumed paradoxical embolism and patent foramen ovale (PFO. Methods: There were two symptomatic patients (29 and 47 years old who underwent percutaneous transcatheter closure of PFO after at least two events of cerebral ischemia; one embolic event had occurred under anti-platelet therapy. For both patients, Amplatzer PFO occluder measuring 25 mm in diameter were used. In both cases, complete occlusion by color Doppler and transesophageal contrast echocardiography investigation was achieved after the procedure and lasted at least up to 3 months after implantation as determined by our follow up. Mean fluoroscopy time was 16.7 minutes. Results: Percutaneous transcatheter closure was technically successful in both patients (100%. No residual shunt was seen at the end of the procedure or in follow-ups. In-hospital follow-up was uneventful. At a mean follow-up of 3 months, no recurrent embolic neurological events were observed. Conclusion: Transcatheter closure of PFO with Amplatzer PFO occluder devices is a safe and effective therapy for patients with previous paradoxical embolism PFO. Percutaneous closure is associated with a high success rate, low incidence of hospital complications, and freedom of cerebral ischemic events.

  18. 78 FR 20625 - Extension of Hearing Record Closure Date

    Science.gov (United States)

    2013-04-05

    ... From the Federal Register Online via the Government Publishing Office DEFENSE NUCLEAR FACILITIES SAFETY BOARD Extension of Hearing Record Closure Date AGENCY: Defense Nuclear Facilities Safety Board. ACTION: Extension of hearing record closure date. SUMMARY: The Defense Nuclear Facilities Safety...

  19. 77 FR 65871 - Extension of Hearing Record Closure Date

    Science.gov (United States)

    2012-10-31

    ... From the Federal Register Online via the Government Publishing Office DEFENSE NUCLEAR FACILITIES SAFETY BOARD Extension of Hearing Record Closure Date AGENCY: Defense Nuclear Facilities Safety Board. ACTION: Extension of hearing record closure date. SUMMARY: The Defense Nuclear Facilities Safety...

  20. Transcatheter closure of patent foramen ovale with the Spider~(TM) patent foramen ovale occluder: a prospective, single-center trial

    Institute of Scientific and Technical Information of China (English)

    ZHANG Cao-jin; HUANG Yi-gao; HUANG Xin-sheng; HUANG Tao; HUANG Wen-hui; SHEN Jun-jun; XUN Zheng-rong

    2010-01-01

    Background Transcatheter closure of patent foramen ovale (PFO) is a promising alternative to surgical closure or anticoagulation therapy to prevent paradoxical embolic events in patients with PFO. Several different devices have been used for transcatheter PFO closure. The aim of the present study was to evaluate the safety and feasibility for closure of PFO with a new PFO occluder, the Spider~(TM) PFO occluder. Methods The device was implanted in the PFO patients under fluoroscopy and transthoracic echocardiography (TTE) using a 10 French delivery sheath employing a femoral vein approach. Aspirin was administered at 100 mg/d for six months after occlusion. The clinical and echocardiographic follow-up of patients were performed at the 24th hour, 1st month, 3rd month, 6th month, and 12th month after occlusion, and yearly thereafter. Results The device was implanted successfully in all 55 patients. No major complications occurred during the perioperative period, such as thromboembolism, occluder dislodgement, infection or myocardial infarction. No residual shunt of the atrial level was shown by transesophageal echocardiography, and no latent arrhythmia or cerebral vesselevents occurred in any cases during follow-up ((35±9) months, range 6-51 months).Conclusion Transcatheter closure of a PFO with the Spider~(TM) PFO occluder is a safe and effective therapeutic option for the secondary prevention of presumed paradoxical embolism. However, randomized trials comparing this device with other devices and therapies have to be performed.

  1. The safety and efficacy of hemostasis with Clo-Sur P.A.D. after transcatheter arterial chemoembolization

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Seung Chai; Jae, Hwan Jun; Kim, Sang Youn; Lee, Whal; Chung, Jin Wook; Park, Jae Hyung [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    2007-04-15

    We wanted to evaluate the safety and efficacy of a new hemostatic device, Clo-Sur P.A.D., at an arterial access site after performing femoral arterial catheterization to achieve transcatheter arterial chemoembolization (TACE). From August 2002 to March 2005, 113 patients who underwent TACE and agreed on using the Clo-Sur P.A.D. were enrolled in this study. We evaluated the mean time interval from compression to the first movement and also to the first walk. We also evaluated such complications as rebleeding, pseudoaneurysm, vascular occlusion, hematoma, infection and pain. For 92 patients who had previous experiences with manual compression, we evaluated their preference of hemostatic method by asking them. Successful hemostasis was achieved with the Clo-Sur P.A.D. in 105 subjects (92%). The mean time interval from compression to the first movement was 201 minutes, and that to the first walk was 267 minutes. There was no statistical difference between the complicated and the uncomplicated groups for the mean time, prothrombin time, Child-Pugh class and platelet count ({rho} > 0.05). Rebleeding occurred in 3 patients (2.7%) and mild hematoma around puncture site was noted in 5 patients (5.4%). Eighty-seven patients (95%) preferred Clo-Sur P.A.D. to the manual compression method. The Clo-Sur P.A.D. is a safe and effective hemostatic device and it provides early ambulation after TACE.

  2. Rural Primary School Closures in England.

    Science.gov (United States)

    Whitfield, Richard C.

    A three-phase interdisciplinary effort between educators and environmental planners is focusing on the social effects of rural primary school reorganization now occuring in England as a result of a declining birth rate and the resulting need for school closure. A questionnaire mailed nationally to rural Local Education Authorities, cross-community…

  3. The Story of a Charter School Closure.

    Science.gov (United States)

    Flynn, Susan L.; Arguelles, Lourdes

    2001-01-01

    The story of a charter school closure is told from the perspectives of students, parents, teachers, and community members, who felt that the sponsoring district revoked the charter for political reasons despite broad local support. The experience underscores the necessity of publicly subjecting the relationship of the public school system and the…

  4. Parallel hierarchical evaluation of transitive closure queries

    NARCIS (Netherlands)

    Houtsma, M.A.W.; Cacace, F.; Ceri, S.

    1991-01-01

    Presents a new approach to parallel computation of transitive closure queries using a semantic data fragmentation. Tuples of a large base relation denote edges in a graph, which models a transportation network. A fragmentation algorithm is proposed which produces a partitioning of the base relation

  5. End-of-year closure - Mail Office

    CERN Multimedia

    GS Department

    2010-01-01

    On the occasion of the annual closure of CERN, there will be no mail distributed on Tuesday 21 December 2010, but mail will be collected in the morning. Nevertheless, it will be possible for you to bring your mail for the departure until 12:00 at building 555-R-002. Mail Office

  6. The Triangle Closure is a Polyhedron

    CERN Document Server

    Basu, Amitabh; Köppe, Matthias

    2011-01-01

    Recently, cutting planes derived from maximal lattice-free convex sets have been studied intensively by the integer programming community. An important question in this research area has been to decide whether the closures associated with certain families of lattice-free sets are polyhedra. For a long time, the only result known was the celebrated theorem of Cook, Kannan and Schrijver who showed that the split closure is a polyhedron. Although some fairly general results were obtained by Andersen, Louveaux and Weismantel [An analysis of mixed integer linear sets based on lattice point free convex sets, Math. Oper. Res. 35, (2010) pp. 233--256], some basic questions have remained unresolved. For example, maximal lattice-free triangles are the natural family to study beyond the family of splits and it has been a standing open problem to decide whether the triangle closure is a polyhedron. In this paper, we resolve this by showing that the triangle closure is indeed a polyhedron, and its number of facets can be ...

  7. 300 Area Process Trenches Closure Plan

    Energy Technology Data Exchange (ETDEWEB)

    Luke, S.N.

    1994-08-15

    Since 1987, Westinghouse Hanford Company has been a major contractor to the US Department of Energy, Richland Operations Office and has served as co-operator of the 300 Area Process Trenches, the waste management unit addressed in this closure plan. For the purposes of the Resource Conservation and Recovery Act, Westinghouse Hanford Company is identified as ``co-operator.`` The 300 Area Process Trenches Closure Plan (Revision 0) consists of a Resource Conservation and Recovery Act Part A Dangerous Waste Permit Application, Form 3 and a Resource Conservation and Recovery Act Closure Plan. An explanation of the Part A Permit Application, Form 3 submitted with this document is provided at the beginning of the Part A Section. The closure plan consists of nine chapters and six appendices. The 300 Area Process Trenches received dangerous waste discharges from research and development laboratories in the 300 Area and from fuels fabrication processes. This waste consisted of state-only toxic (WT02), corrosive (D002), chromium (D007), spent halogenated solvents (F001, F002, and F003), and spent nonhalogented solvent (F005). Accurate records are unavailable concerning the amount of dangerous waste discharged to the trenches. The estimated annual quantity of waste (item IV.B) reflects the total quantity of both regulated and nonregulated waste water that was discharged to the unit.

  8. Opening up closure. Semiotics across scales

    Science.gov (United States)

    Lemke

    2000-01-01

    The dynamic emergence of new levels of organization in complex systems is related to the semiotic reorganization of discrete/continuous variety at the level below as continuous/discrete meaning for the level above. In this view both the semiotic and the dynamic closure of system levels is reopened to allow the development and evolution of greater complexity.

  9. Individual Consequences of Plant Closures and Cutbacks

    DEFF Research Database (Denmark)

    Andersen, Steen

    1991-01-01

    This thesis describes the segment of unemployment which has its origin in major closures and cutbacks. The argument for this is to make it possible to describe and to analyse a flow into and a flow out of a population of unemployed. Given a major dismissal the following questions are to be answer...

  10. Primary closure of equine laryngotomy incisions

    DEFF Research Database (Denmark)

    Lindegaard, C.; Karlsson, L.; Ekstrøm, C. T.;

    2016-01-01

    The objective was to report healing characteristics and complications after primary closure of equine laryngotomies and analyse factors potentially associated with complications. This retrospective case series of the medical records of horses (n = 180) undergoing laryngoplasty and laryngotomy inc...

  11. Parallel hierarchical evaluation of transitive closure queries

    NARCIS (Netherlands)

    Houtsma, M.A.W.; Houtsma, M.A.W.; Cacace, F.; Ceri, S.

    1991-01-01

    Presents a new approach to parallel computation of transitive closure queries using a semantic data fragmentation. Tuples of a large base relation denote edges in a graph, which models a transportation network. A fragmentation algorithm is proposed which produces a partitioning of the base relation

  12. 50 CFR 648.141 - Closure.

    Science.gov (United States)

    2010-10-01

    ... 50 Wildlife and Fisheries 8 2010-10-01 2010-10-01 false Closure. 648.141 Section 648.141 Wildlife... inaction of one or more states will cause the applicable target exploitation rate specified in § 648.140(a... state has been remedied by that state without causing the applicable specified target exploitation...

  13. Synthesis of azaphenanthridines via anionic ring closure

    DEFF Research Database (Denmark)

    Hansen, Henriette Møller; Lysén, M.; Begtrup, M.;

    2005-01-01

    A new and convergent synthesis of azaphenanthridines via an anionic ring closure is reported. Ortho-lithiation/in situ borylation of cyanopyridines produces the corresponding cyanopyridylboronic esters, which undergo a Suzuki-Miyaura cross-coupling to give the key intermediates. Addition of lithium...

  14. 50 CFR 635.28 - Closures.

    Science.gov (United States)

    2010-10-01

    ... for the shark species or complexes specified in § 635.27(b)(1) will remain open. (2) When NMFS..., provided the harvesting vessel does no fishing after the closure in the Atlantic Ocean north of 5 N. lat., and reports positions with a vessel monitoring system, as specified in § 635.69. Additionally,...

  15. Permanent Closure of the TAN-664 Underground Storage Tank

    Energy Technology Data Exchange (ETDEWEB)

    Bradley K. Griffith

    2011-12-01

    This closure package documents the site assessment and permanent closure of the TAN-664 gasoline underground storage tank in accordance with the regulatory requirements established in 40 CFR 280.71, 'Technical Standards and Corrective Action Requirements for Owners and Operators of Underground Storage Tanks: Out-of-Service UST Systems and Closure.'

  16. 25 CFR 573.6 - Order of temporary closure.

    Science.gov (United States)

    2010-04-01

    ... or a customer. (7) A management contractor operates for business without a contract that the Chairman... 25 Indians 2 2010-04-01 2010-04-01 false Order of temporary closure. 573.6 Section 573.6 Indians... ENFORCEMENT § 573.6 Order of temporary closure. (a) When an order of temporary closure may issue...

  17. A Simple Method for Thoracotomy Closure Avoiding Intercostal Nerve Damage

    Directory of Open Access Journals (Sweden)

    Ufuk Cagirici

    2016-09-01

    Full Text Available It is well known that intercostal nerve damage during thoracotomy closure causes severe postoperative pain. A simple closure technique is proposed for intercostal nerve-sparing during thoracotomy opening and closure. We think that this maneuver may avoid intercostal nerve compression.

  18. 27 CFR 28.102 - Bottles to have closures affixed.

    Science.gov (United States)

    2010-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2010-04-01 2010-04-01 false Bottles to have closures... Transportation to a Manufacturing Bonded Warehouse § 28.102 Bottles to have closures affixed. Every bottle containing distilled spirits to be withdrawn under the provisions of this subpart shall have a closure...

  19. 78 FR 1206 - Second Extension of Hearing Record Closure Date

    Science.gov (United States)

    2013-01-08

    ... SAFETY BOARD Second Extension of Hearing Record Closure Date AGENCY: Defense Nuclear Facilities Safety Board. ACTION: Second extension of hearing record closure date. SUMMARY: The Defense Nuclear Facilities... closure date to January 2, 2013 (77 FR 65871). Extension of Time: The Board now extends the period of...

  20. Kinetics and Mechanics of Asymmetric Closure in the Venus Flytrap's Fast Motion

    Science.gov (United States)

    Chen, Zi; Xie, Stephen

    2014-03-01

    In this work, we aimed to investigate the biomechanical mechanisms behind rapid movements in plants by studying the Venus flytrap (Dionaea Muscipula) and some of the peculiar features of its unique snapping mechanism. After two consecutive stimulations of the interior trigger hairs, equilibrium within each leaf lobe is upset and each transitions from a stable convex state to a stable concave state. While one could assume the motions of two leaves to be symmetric, they are not in a lot of cases. When stimulation of trigger hairs occurs unilaterally, for example, the stimulated leaf lobe sometimes closes more rapidly than the other leaf lobe. We recorded multiple closures on a number of traps with varied stimuli locations with a high speed camera to explore the roles of intrinsic and extrinsic factors that drive this asymmetric trap closure. Three material points were tracked over time for each closure, allowing calculation of the angular speed and acceleration of the distal edge of each lobe. Analysis of the angle differences between lobes and the location of stimuli clarified how extrinsic, unilateral stimuli drive asymmetric closure. It can be argued that there could also be some biological advantages in capturing moving preys through this asymmetric motion. Ultimately, the principles derived from studying the Venus flytrap may inspire designs for bio-mimetic devices leading to a range of engineering applications.

  1. Evaluation of stapled closure following laryngectomy for carcinoma larynx in an Indian tertiary cancer centre

    Directory of Open Access Journals (Sweden)

    S Babu

    2015-01-01

    Full Text Available Background And Aim: Stapling devices are used for pharyngeal closure after laryngectomy for the past few decades although it has not gained wide acceptance. This study is aimed at evaluating the role of stapler in pharyngeal closure after laryngectomy. Methods: Thirty consecutive patients who underwent stapled laryngectomy at our institution from October 2004 to February 2008 were evaluated retrospectively. Linear stapler (Proximate TX 60; Ethicon Inc. was used for closure of neopharynx. Results: There were 28 males and 2 females with mean age of 54.5 years (54.5 ± 11.2. Nineteen of these patients (63.3% had salvage laryngectomy and two patients (6.7% had laryngectomy for a second primary tumor. Twenty-eight patients had total laryngectomy (TL, whereas two had extended TL. Eight patients had salivary leak (26.7%. Of these, 6 (75% had prior radiation. All salivary leaks except one were managed conservatively. Follow-up ranged from 7 to 54 months (median: 21 months. Seven patients (23.3% developed recurrence, six at the stoma, of which 5 (83.3% had initial extension of disease to the subglottis. Four-year disease-free survival was 54.4%. Conclusion: Pharyngeal closure by linear stapler is an efficient and safe method of fashioning the neopharynx after laryngectomy with no added risk of occurrence of pharyngocutaneous fistula in primary and salvage laryngectomies.

  2. Transcatheter closure of the patent foramen ovale in children: intermediate-term follow-up results.

    Science.gov (United States)

    Sel, Kutay; Aykan, Hakan H; Duman, Derya; Aypar, Ebru; Özkutlu, Süheyla; Alehan, Dursun; Karagöz, Tevfik

    2017-10-01

    The patent foramen ovale is almost a normal anatomical hole between the atria with ~30% incidence in the general population. It has been suggested that the patent foramen ovale is the cause of some neurological events, which is explained by paradoxical embolism. Transcatheter closure of the patent foramen ovale is a common procedure in adult patients with cerebral ischaemic events, but there are limited data investigating the results in children. Between January, 2005 and February, 2014, 17 patients' patent foramen ovales were closed by the transcatheter approach in our department. The indications for closure were transient ischaemic attack in 10 patients, stroke in four patients, and migraine in three patients. The mean age and mean weight at the time of the procedure were 11.1±3.7 years and 42.1±15.4 kg, respectively. We asked our patients whether their previous ailments continued. All patients responded to the study survey. In 15 patients, ailments did not continue after patent foramen ovale closure and they significantly decreased in two of them. We suggest that under the right conditions device closure of the patent foramen ovale is a safe solution for these cryptogenic ischaemic events and migraine.

  3. Opening and closure forces of sliding mechanisms of different self-ligating brackets

    Directory of Open Access Journals (Sweden)

    Paola GANDINI

    2013-06-01

    Full Text Available Self-ligating brackets engage the wire by means of a slide mechanism. Forces that have to be applied to open and close the sliding mechanism of brackets are still unknown. Objective The aim of this study was to measure and compare the opening and closure forces of different self-ligating brackets. Material and Methods Three different stainless steel self-ligating brackets (Carriere LX, Ortho Organizers; F1000, Leone; Damon Q, Ormco were tested. For each different bracket, 20 maxillary right central incisors and 20 mandibular right central incisors were used. Opening and closure forces were measured using an Instron Universal Testing Machine. Statistical analysis was performed and ANOVA and Tukey tests were carried out. Results Opening forces were registered between 1.1 N and 5.6 N, whereas closure forces were recorded between 1.57 N and 4.87 N. Significant differences were detected among the different brackets and between the two prescriptions tested. Conclusion The knowledge of different opening and closure forces of self-ligating brackets can help the orthodontist in the clinical management of these devices.

  4. Transcatheter Closure of Patent Ductus Arteriosus and Atrial Septal Defects Using the Amplatzer Occluder

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    Objective:To evalte the efficiency,safety and complications of transcatheter closure of patent ductus arteriosus (PDA) or secundum atrial septal defects (ASD)using the Amplatzer occluder device.Methods:30 patients underwent transcatheter closure of PDA or ASD with the Amplatzer occluder.The lateral descending aortographies were performed to evaluate immediate results in the 20 patients of PDA.Hemodynamics was studied before and after the procedure.X-ray and echocardiography were performed in order to detect residual shunt and recanalization.Results:The device was successfully implanted in 28 patients.There was on clinical evidence of hemolysis andon incidence of device emboliszation.The median operation time waw 56min and median fluoroscopy time was 11min .The devices'positions were optmal and on residual shunt was found 24h and 1month after the procedure No complicatios were observed during the 3-month follow-up in 25 patients.Conclusions:The Amplatzer occluder device is a highly efficient prosthesis that can be safely applied in most patients with PDA or ASD.

  5. Percutaneous patent foramen ovale closure: the Paradoxical Cerebral Embolism Prevention Registry.

    Science.gov (United States)

    Paiva, Luís; Dinis, Paulo; Providência, Rui; Costa, Marco; Margalho, Susana; Goncalves, Lino

    2015-03-01

    The natural history and therapeutic interventions for secondary prevention after a cerebrovascular event in patients with patent foramen ovale (PFO) are not yet established. This study aims to assess the safety and efficacy of percutaneous PFO closure in a population of patients with ischemic cerebrovascular disease of unknown etiology. This prospective observational study included patients with a history of cryptogenic transient ischemic attack (TIA) or stroke who underwent percutaneous PFO closure. The effectiveness of the device for the secondary prevention of TIA or stroke was assessed by comparing observed events in the sample with expected events for this clinical setting. The sample included 193 cases of percutaneous PFO closure (age 46.4 ± 13.1 years, 62.2% female) with a mean follow-up of 4.3 ± 2.2 years, corresponding to a total exposure to ischemic events of 542 patient-years. The high-risk characteristics of the PFO were assessed prior to device implantation. There were seven primary endpoint events during follow-up (1.3 per 100 patient-years), corresponding to a relative risk reduction of 68.2% in recurrent TIA or stroke compared to medical therapy alone. The procedure was associated with a low rate of device- or intervention-related complications (1.5%). In this long-term registry, percutaneous PFO closure was shown to be a safe and effective therapy for the secondary prevention of cryptogenic stroke or TIA. Copyright © 2014 Sociedade Portuguesa de Cardiologia. Published by Elsevier España. All rights reserved.

  6. Transcatheter Closure of Patent Ductus Arteriosus in Adolescents and Adults: A Case Series

    Directory of Open Access Journals (Sweden)

    Sukman Tulus Putra

    2017-02-01

    Full Text Available During 11 years period from January 2005 to December 2015 there were 18 adolescent and adult patients  who underwent transcatheter closure of PDA using PDA Amplatzer Duct Occluder (ADO. There were 9 cases with age of 14 to 18 years and 9 cases with age of more than 18 years where the oldest case was 46 years old. Two cases were male and 16 cases were female. Prior to procedures, clinical assessment, ECG, chest x-ray and transthoracic echocardiography (TTE were performed to confirm the diagnosis of PDA. The procedures of device implantation was performed under conscious sedation in adults and using general anesthesia in adolescents.The size of PDA ranged from 1.6 mm to 11.1 mm. Based on Kritchenko classification, the type of PDA were 15 type A1 and 3type A2. Flow ratio between pulmonary to systemic circulation was between 1.1 and 5.9. The procedure time ranged from 60-189 minutes and the fluoroscopic time 7.1-77.3 minutes. The PA pressure ranged from 22 to 63 mmHg. Immediate results after procedures as seen in angiography showed complete closure in 14 cases and smoky residual shunt or minimal residual shunts in 4 cases, which probably due to the temporary leaking through the devices. In 24 hours, complete closure was achieved in all cases (100% and continued until 1months. At 6 month follow up, there was no residual shunts detected and also there was no significant complications, such as device embolization or recanalization. This case series suggest that transcatheter closure of PDA in adolescents and adults using Amplatzer duct occluder (ADO is effective and has excellent resultswithout significant complication. However, long-term follow up is required to assess long term efficacy and safety.

  7. Insertion devices

    CERN Document Server

    Bahrdt, J

    2006-01-01

    The interaction of an insertion device with the electron beam in a storage ring is discussed. The radiation property including brightness, ux and polarization of an ideal and real planar and helical / elliptical device is described. The magnet design of planar, helical, quasiperiodic devices and of devices with a reduced on axis power density are resumed.

  8. 77 FR 75186 - Notice of Closure, Target Shooting Public Safety Closure on the Lake Mountains in Utah County, UT

    Science.gov (United States)

    2012-12-19

    ... Bureau of Land Management Notice of Closure, Target Shooting Public Safety Closure on the Lake Mountains... approximately 900 acres of public land on the Lake Mountains in Utah County, Utah, to recreational target... Lake Mountains area. DATES: This target shooting closure within the described area will remain in...

  9. Temporary Closure of the Open Abdomen: A Systematic Review on Delayed Primary Fascial Closure in Patients with an Open Abdomen

    NARCIS (Netherlands)

    Boele van Hensbroek, P.; Wind, J.; Dijkgraaf, M.G.W.; Busch, O.R.C.; Goslings, J.C.

    2009-01-01

    Background This study was designed to systematically review the literature to assess which temporary abdominal closure (TAC) technique is associated with the highest delayed primary fascial closure (FC) rate. In some cases of abdominal trauma or infection, edema or packing precludes fascial closure

  10. Temporary Closure of the Open Abdomen: A Systematic Review on Delayed Primary Fascial Closure in Patients with an Open Abdomen

    NARCIS (Netherlands)

    Boele van Hensbroek, P.; Wind, J.; Dijkgraaf, M.G.W.; Busch, O.R.C.; Goslings, J.C.

    2009-01-01

    Background This study was designed to systematically review the literature to assess which temporary abdominal closure (TAC) technique is associated with the highest delayed primary fascial closure (FC) rate. In some cases of abdominal trauma or infection, edema or packing precludes fascial closure

  11. Transcatheter Mitral Paravalvular Leak Closure Facilitated by Preprocedural Cardiac CT for Simulation of Fluoroscopic Anatomy and Paravalvular Defect Localization.

    Science.gov (United States)

    Korsholm, Kasper; Mortensen, Ulrik; Jensen, Jesper Møller; Piazza, Nicolo; Thériault-Lauzier, Pascal; Nielsen-Kudsk, Jens Erik

    2017-02-01

    Paravalvular leakage (PVL) occurs in 6%-15% of cases after surgical heart valve replacement. A percutaneous approach is increasingly used to close PVLs as an alternative to repeat surgery. Computed tomography (CT) can be used for simulation of fluoroscopic cardiac anatomy. This technique allows preprocedural definition of optimal C-arm angulations and PVL localization in reference to fluoroscopic views. It is very helpful for guidewire crossing of the PVL and positioning of the closure device. We report a case with the first use of dedicated software for fluoroscopic simulation (FluoroCT) in transcatheter mitral PVL closure.

  12. [The transcatheter closure of patent ductus arteriosus. The initial experience].

    Science.gov (United States)

    Vázquez-Antona, C A; Rijlaarsdam, M; Gaspar, J; Gil Moreno, M; Buendía Hernández, A; Martínez Ríos, M A; Attie, F

    1993-01-01

    Percutaneous closure of the patent ductus arteriosus (PDA) has been recently reported to be an effective alternative in the treatment of patients with ductal shunting. We report the initial experience and results during follow-up of percutaneous ductal occlusion with the Rashkind occluder (USCI) in six patients with isolated PDA. Ages ranged from 3 to 23 years. Diagnosis was corroborated with two dimensional and Doppler echocardiography in all patients. During cardiac catheterization systolic pulmonary artery pressure oscillated between 22 and 64 mmHg and Qp/Qs ratio between 1.3 and 4.1. In two patients prosthesis of 12 mm were used and in the remaining prosthesis of 17 mm. Only one patient demonstrated total occlusion during immediate control aortography, the other patients presented central residual shunting over the occluder. In the three patients occlusion with balloon-catheter was added to the procedure, resulting in total occlusion in two and significant reduction of the shunt magnitude in one. Two technical problems were resolved satisfactorily. None of the cases presented device embolization. Mean follow-up was 23.8 months with control echocardiograms at 24 hours, 1, 4, 12 and 24 months. In all patients immediate reduction of the left atrial dimension was demonstrated. Three patients presented residual shunts in the first 24 hours. In two of them total occlusion had occurred after one month and the other patient persisted with a small residual shunt until one year after the procedure. In conclusion, in this small study group good results were obtained with percutaneous ductal closure.

  13. The proposal of the closure element pipe

    Directory of Open Access Journals (Sweden)

    Fojtášek Kamil

    2017-01-01

    Full Text Available The present paper summarizes the basic equations describing the behavior of butterfly valves during the fluid flow. Butterfly valves are used as a safety element in the energy industry, petrochemical industry, in steam lines etc. The paper describes the theoretical determination of the control torque on the closure element, the torque causes the opening and closing of butterfly valve. Determination of this torque depends on many factors, geometry of the closure element, misalignment to the axis of fluid flow, control method of valve, method of imposition of the moving member and of course on the operating parameters. Correct determination of the torque affects the proper design butterfly valves and ensure its functionality, which can prevent damage to other elements of the monitoring system.

  14. The proposal of the closure element pipe

    Science.gov (United States)

    Fojtášek, Kamil; Krutil, Jaroslav; Dvořák, Lukáš

    The present paper summarizes the basic equations describing the behavior of butterfly valves during the fluid flow. Butterfly valves are used as a safety element in the energy industry, petrochemical industry, in steam lines etc. The paper describes the theoretical determination of the control torque on the closure element, the torque causes the opening and closing of butterfly valve. Determination of this torque depends on many factors, geometry of the closure element, misalignment to the axis of fluid flow, control method of valve, method of imposition of the moving member and of course on the operating parameters. Correct determination of the torque affects the proper design butterfly valves and ensure its functionality, which can prevent damage to other elements of the monitoring system.

  15. A regenerative approach towards mucosal fenestration closure.

    Science.gov (United States)

    Gandi, Padma; Anumala, Naveen; Reddy, Amarender; Chandra, Rampalli Viswa

    2013-06-06

    Mucosal fenestration is an opening or an interstice through the oral mucosa. A lesion which occurs with greater frequency than generally realised, its occurrence is attributed to a myriad of causes. Mucogingival procedures including connective tissue grafts, free gingival grafts and lateral pedicle grafts are generally considered to be the treatment of choice in the closure of a mucosal fenestration. More often, these procedures are performed in conjunction with other procedures such as periradicular surgery and with bone grafts. However, the concomitant use of gingival grafts and bone grafts in mucosal fenestrations secondary to infections in sites exhibiting severe bone loss is highly debatable. In this article, we report two cases of mucosal fenestrations secondary to trauma and their management by regenerative periodontal surgery with the placement of guided tissue regeneration membrane and bone graft. The final outcome was a complete closure of the fenestration in both the cases.

  16. Mid-term results of interventional closure of patent foramen ovale with the Occlutech Figulla(®) Flex II Occluder.

    Science.gov (United States)

    Neuser, Jonas; Akin, Muharrem; Bavendiek, Udo; Kempf, Tibor; Bauersachs, Johann; Widder, Julian D

    2016-11-10

    Patients with a patent foramen ovale (PFO) who suffered from stroke, TIA or peripheral paradoxical embolism are at substantial risk for recurrent neurologic events and in need for secondary prevention. Interventional closure of PFO has been performed for over 20 years. Numerous devices have been developed and used for treatment. We investigated PFO closure with the third generation Occlutech Figulla(®) Flex II Occluder device. Between 2012 and 2015 57 patients (mean age 47.3 ± 1.5 years) who had suffered from a thromboembolic event of unknown cause underwent transcatheter PFO closure with the Occlutech Figulla(®) Flex II Occluder at our department. 68.4 % of all patients had suffered from cryptogenic stroke, while TIA had occurred in 28.1 %. Almost all patients were diagnosed with an atrial septum aneurysm (90.9 %) and a severe right-to-left shunt grade 3: >20 microbubbles (92.0 %). Follow-up was done 6 months post intervention by clinical examination and transesophageal contrast echocardiography. No major periprocedural or in-hospital complication occurred. Closure was sufficient with no residual right-to-left shunt in 94.4 % of all patients at 6 months post implantation and only minimal residual shunt in three cases. There were no thrombotic formations associated to the occluder device. Atrial fibrillation occurred in one patient and a recurrent cerebral ischemic event was seen in one patient, who suffered from another TIA. The Occlutech Figulla(®) Flex II Occluder device and its delivery system is safe and provides sufficient closure of PFO in patients who suffered from cryptogenic stroke, TIA or paradoxical peripheral embolism.

  17. Use of StarClose for brachial artery closure after percutaneous endovascular interventions.

    Science.gov (United States)

    Puggioni, Alessandra; Boesmans, Evelyne; Deloose, Koen; Peeters, Patrick; Bosiers, Marc

    2008-01-01

    The objective of this study was to evaluate a percutaneous extravascular closure device (StarClose, Abbott Vascular, Redwood City, CA) after brachial endovascular approach. From 2004 to 2006, 29 patients received StarClose for brachial closure. Primary endpoints were successful deployment and absence of procedure-related morbidity, secondary endpoints were brachial artery patency on duplex and absence of late (> 30 days) complications. The device was successfully deployed in all patients. In two patients (6.8%) local complications occurred: one patient developed a large hematoma successfully treated with prolonged compression and a second patient presented with brachial artery occlusion requiring operative intervention. After a mean follow-up of 7.5+/-7.2 months, all patients had a palpable brachial/radial pulse; none had signs of infection, distal embolization or neurological deficits. On ultrasound b-mode imaging, the clip was visible as a 4 mm echolucent area at the outer anterior wall of the artery. Based on the peak systolic velocity ratios between the site of StarClose and proximal brachial artery (mean 1.08+/-0.2), none of the studied patients had a significant stenosis at the site of closure. StarClose is safe and effective in providing hemostasis following interventional procedures through the brachial artery; further advantages include patients comfort and early discharge.

  18. Transcatheter closure of tubular type patent ductus arteriosus using Amplatzer� ductal occluder II: a case report

    Directory of Open Access Journals (Sweden)

    Mulyadi M Djer

    2013-09-01

    Full Text Available Patent ductus arteriosus (PDA is a common congenital heart disease, accounting for 5-10% of all congenital heart diseases. The incidence of PDA is even higher in preterm neonates, ranging from 20-60%.1-4 Closure of PDA is indicated in all cases, except for duct-dependent congenital heart diseases or PDA with Eisenmenger syndrome.1,5,6 In small asymptomatic PDAs, closure is indicated to prevent the risk of complications, such as endarteritis, endocarditis, aneurysm of ductus arteriosus, or congestive heart failure.1,2,7 In recent years, interventional cardiology has become a gold standard therapy for the majority of PDA cases beyond neonatal age. Since its introduction in 1967, many devices and methods have been developed to allow transcatheter closure of virtually all PDAs, regardless of size or configuration. Nevertheless, the tubular shape (type C PDA, which has the highest residual shunt rate, still poses a great challenge for the interventionist.8-10 The second generation of Amplatzer® device occluders (ADO II, released in 2007, has been suggested to be effective in closing tubular PDAs.10 The purpose of this study was to report the initial clinical experience using ADO II to close a tubular type PDA in Indonesia

  19. Restoration of eye closure in facial paralysis using implantable electromagnetic actuator.

    Science.gov (United States)

    Hasmat, Shaheen; Lovell, Nigel H; Suaning, Gregg J; Low, Tsu-Hui Hubert; Clark, Jonathan

    2016-11-01

    The most devastating outcome of facial nerve paralysis is the inability to completely close the eye as it can lead to corneal ulceration and loss of vision. Gravity-assisted eye closure with upper lid loading is commonly used; however it is limited in replicating physiological eye closure to adequately lubricate the cornea. Superior results can be obtained using more advanced reconstructive approaches, however they depend on nerve regrowth which may be unpredictable and prolonged. This report describes a novel technique for creating an active eye closure using an implantable actuator. A generated magnetic field creates lateral movement in an electromagnet that is translated to the eyelid through a sling design. The device is powered wirelessly through a transcutaneous induction link and can be hermetically encapsulated for patient safety. The initial phase of device development is presented including data of a fully functioning prototype and the results of its application in animal and human cadavers. Copyright © 2016 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  20. The Galois closure of Drinfeld modular towers

    DEFF Research Database (Denmark)

    Bassa, Alp; Beelen, Peter

    2011-01-01

    In this article we study Drinfeld modular curves X0(pn) associated to congruence subgroups Γ0(pn) of GL(2,Fq[T]) where p is a prime of Fq[T]. For n>r>0 we compute the extension degrees and investigate the structure of the Galois closures of the covers X0(pn)→X0(pr) and some of their variations. T...

  1. Notice of car park and road closures

    CERN Multimedia

    2006-01-01

    The arrival of one of the end caps of the CMS Tracker in Building 186 will result in the temporary closure of the following car parks: Building186: south entrance Building 613 Building 28 Building181: south entrance Building 600 Building 31 Route Oppenheimer The car parks concerned will be closed from Monday 30 October until the evening of Tuesday 31 October. Thank you for your cooperation. PH-CMT Group Tel. 164569

  2. Notice of car park and road closures

    CERN Multimedia

    2006-01-01

    The arrival of one of the end caps of the CMS Tracker in Building 186 will result in the temporary closure of the following car parks: Building186: south entrance Building 613 Building 28 Building181: south entrance Building 600 Building 31 Route Oppenheimer The car parks concerned will be closed from Sunday 22 October until the evening of Monday 23 October. Thank you for your cooperation. PH-CMT Group Tel. 164569

  3. Calcined solids storage facility closure study

    Energy Technology Data Exchange (ETDEWEB)

    Dahlmeir, M.M.; Tuott, L.C.; Spaulding, B.C. [and others

    1998-02-01

    The disposal of radioactive wastes now stored at the Idaho National Engineering and Environmental Laboratory is currently mandated under a {open_quotes}Settlement Agreement{close_quotes} (or {open_quotes}Batt Agreement{close_quotes}) between the Department of Energy and the State of Idaho. Under this agreement, all high-level waste must be treated as necessary to meet the disposal criteria and disposed of or made road ready to ship from the INEEL by 2035. In order to comply with this agreement, all calcined waste produced in the New Waste Calcining Facility and stored in the Calcined Solids Facility must be treated and disposed of by 2035. Several treatment options for the calcined waste have been studied in support of the High-Level Waste Environmental Impact Statement. Two treatment methods studied, referred to as the TRU Waste Separations Options, involve the separation of the high-level waste (calcine) into TRU waste and low-level waste (Class A or Class C). Following treatment, the TRU waste would be sent to the Waste Isolation Pilot Plant (WIPP) for final storage. It has been proposed that the low-level waste be disposed of in the Tank Farm Facility and/or the Calcined Solids Storage Facility following Resource Conservation and Recovery Act closure. In order to use the seven Bin Sets making up the Calcined Solids Storage Facility as a low-level waste landfill, the facility must first be closed to Resource Conservation and Recovery Act (RCRA) standards. This study identifies and discusses two basic methods available to close the Calcined Solids Storage Facility under the RCRA - Risk-Based Clean Closure and Closure to Landfill Standards. In addition to the closure methods, the regulatory requirements and issues associated with turning the Calcined Solids Storage Facility into an NRC low-level waste landfill or filling the bin voids with clean grout are discussed.

  4. Late erosion of Amplatzer septal occluder device resulting in cardiac tamponade.

    Science.gov (United States)

    Tchantchaleishvili, Vakhtang; Melvin, Amber L; Ling, Frederick S; Knight, Peter A

    2014-12-01

    Transcatheter device closure of atrial septal defects (ASDs) is a minimally invasive technique that offers an alternative to conventional surgical repair. There are risks imposed by this technique; however, they compare favourably with risks of surgical closure. Here, we present a case of a 59-year old male with late erosion of an Amplatzer septal occluder device resulting in cardiac tamponade 5 years after device placement. To the best of our knowledge, cardiac tamponade this late after device placement has not yet been reported. Septal occlusion device erosion remains a major issue among the risks imposed by device closure of an ASD. More data are needed to better understand its true causes and possible solutions.

  5. A Quadratic Closure for Compressible Turbulence

    Energy Technology Data Exchange (ETDEWEB)

    Futterman, J A

    2008-09-16

    We have investigated a one-point closure model for compressible turbulence based on third- and higher order cumulant discard for systems undergoing rapid deformation, such as might occur downstream of a shock or other discontinuity. In so doing, we find the lowest order contributions of turbulence to the mean flow, which lead to criteria for Adaptive Mesh Refinement. Rapid distortion theory (RDT) as originally applied by Herring closes the turbulence hierarchy of moment equations by discarding third order and higher cumulants. This is similar to the fourth-order cumulant discard hypothesis of Millionshchikov, except that the Millionshchikov hypothesis was taken to apply to incompressible homogeneous isotropic turbulence generally, whereas RDT is applied only to fluids undergoing a distortion that is 'rapid' in the sense that the interaction of the mean flow with the turbulence overwhelms the interaction of the turbulence with itself. It is also similar to Gaussian closure, in which both second and fourth-order cumulants are retained. Motivated by RDT, we develop a quadratic one-point closure for rapidly distorting compressible turbulence, without regard to homogeneity or isotropy, and make contact with two equation turbulence models, especially the K-{var_epsilon} and K-L models, and with linear instability growth. In the end, we arrive at criteria for Adaptive Mesh Refinement in Finite Volume simulations.

  6. Stochastic particle acceleration and statistical closures

    Energy Technology Data Exchange (ETDEWEB)

    Dimits, A.M.; Krommes, J.A.

    1985-10-01

    In a recent paper, Maasjost and Elsasser (ME) concluded, from the results of numerical experiments and heuristic arguments, that the Bourret and the direct-interaction approximation (DIA) are ''of no use in connection with the stochastic acceleration problem'' because (1) their predictions were equivalent to that of the simpler Fokker-Planck (FP) theory, and (2) either all or none of the closures were in good agreement with the data. Here some analytically tractable cases are studied and used to test the accuracy of these closures. The cause of the discrepancy (2) is found to be the highly non-Gaussian nature of the force used by ME, a point not stressed by them. For the case where the force is a position-independent Ornstein-Uhlenbeck (i.e., Gaussian) process, an effective Kubo number K can be defined. For K << 1 an FP description is adequate, and conclusion (1) of ME follows; however, for K greater than or equal to 1 the DIA behaves much better qualitatively than the other two closures. For the non-Gaussian stochastic force used by ME, all common approximations fail, in agreement with (2).

  7. Creativity & Cognitive Closure (Creatividad y cierre cognitivo

    Directory of Open Access Journals (Sweden)

    Melike Hazir

    2015-02-01

    Full Text Available Abstract The aim of this paper is to present the relationship between the need for cognitive closure (NFC and creativity. In light of previous research, a theoretical foundation is established for the term creativity. Next the social-cognitive phenomenon of the need for cognitive closure is explained based on the theory of Kruglanski and Webster, and considering the tendencies of urgency and permanency. Conclusion: The role of creativity is to control cognitive closure in order to solve problems that arise during the learning process and usually during the life. Resumen El objetivo de este trabajo es presentar la relación entre la necesidad de cierre cognitivo (NCC y la creatividad. A la luz de las investigaciones realizadas, se establece la base teórica para el término de creatividad y la explica del fenómeno socio-cognitivo de necesidad de cierre cognitivo en base a la teoría de Kruglanski y Webster, teniendo en cuenta las tendencias de urgencia y permanencia. Conclusión: La creatividad tiene un papel importante de control del cierre cognitivo con el fin de resolver los problemas que surjan durante el proceso de aprendizaje y en general durante la vida.

  8. Endonasal endoscopic closure of cerebrospinal fluid rhinorrhea.

    Science.gov (United States)

    Schmerber, S; Righini, C; Lavielle, J P; Passagia, J G; Reyt, E

    2001-02-01

    The authors review their experience with endoscopic repair of skull base defects associated with cerebrospinal fluid (CSF) rhinorrhea involving the paranasal sinuses. A total of 22 patients was treated endoscopically between 1992 and 1998. The repair method consisted of closure of the CSF fistula with a free autologous abdominal fat graft and fibrin glue, supported with a sheet of silastic. The primary closure rate was 82% (18/22), and the overall closure rate was 95.5% (21/22) without recurrence or complications within an average follow-up of 5 years (14-83 months). A single patient still complains of cerebrospinal rhinorrhea, although this was never proved by any clinical, endoscopic, or biological (beta(2)-transferrin) examination. The repair of ethmoidal-sphenoidal cerebrospinal fluid fistulae by endonasal endoscopic surgery is an excellent technique, both safe and effective. Fat is a material of choice, as it is tight and resists infection well. The technique and indications for endoscopic management of cerebrospinal fluid leaks are discussed.

  9. VR closure rates for two vocational models.

    Science.gov (United States)

    Fraser, Virginia V; Jones, Amanda M; Frounfelker, Rochelle; Harding, Brian; Hardin, Teresa; Bond, Gary R

    2008-01-01

    The Individual Placement and Support (IPS) model of supported employment is an evidence-based practice for individuals with psychiatric disabilities. To be financially viable, IPS programs require funding from the state-federal vocational rehabilitation (VR) system. However, some observers have questioned the compatibility of IPS and the VR system. Using a randomized controlled trial comparing IPS to a well-established vocational program called the Diversified Placement Approach (DPA), we examined rates of VR sponsorship and successful VR closures. We also describe the establishment of an active collaboration between a psychiatric rehabilitation agency and the state VR system to facilitate rapid VR sponsorship for IPS clients. Both IPS and DPA achieved a 44% rate of VR Status 26 closure when considering all clients entering the study. IPS and DPA averaged similar amount of time to achieve VR sponsorship. Time from vocational program entry to Status 26 was 51 days longer on average for IPS. Even though several IPS principles seem to run counter to VR practices, such as zero exclusion and rapid job search, we found IPS closure rates comparable to those for DPA, a vocational model that screens for readiness, provides prevocational preparation, and extensively uses agency-run businesses.

  10. Folate receptors and neural tube closure.

    Science.gov (United States)

    Saitsu, Hirotomo

    2017-02-28

    Neural tube defects (NTD) are among the most common human congenital malformations, affecting 0.5-8/1000 of live births. Human clinical trials have shown that periconceptional folate supplementation significantly decreases the occurrence of NTD in offspring. However, the mechanism by which folate acts on NTD remains largely unknown. Folate receptor (Folr) is one of the three membrane proteins that mediate cellular uptake of folates. Recent studies suggest that mouse Folr1 (formerly referred to as Fbp1) is essential for neural tube closure. Therefore, we examined spatial and temporal expression patterns of Folr1 in developing mouse embryos, showing a close association between Folr1 and anterior neural tube closure. Transient transgenic analysis was performed using lacZ as a reporter; we identified a 1.1-kb enhancer that directs lacZ expression in the neural tube and optic vesicle in a manner that is similar to endogenous Folr1. The 1.1-kb enhancer sequences were highly conserved between humans and mice, suggesting that human FOLR1 is associated with anterior neural tube closure in humans. Several experimental studies in mice and human epidemiological and genetics studies have suggested that folate receptor abnormalities are involved in a portion of human NTDs, although the solo defect of FOLR1 did not cause NTD.

  11. Hospital admissions before and after shipyard closure.

    Science.gov (United States)

    Bartley, M; Fagin, L

    1990-03-01

    "To determine the effect of job loss on health an investigation was made of admissions to hospitals in 887 men five years before and three years after the closure of a Danish shipyard. The control group comprised 441 men from another shipyard. The information on hospital admissions was obtained from the Danish national register of patients. The relative risk of admission in the control group dropped significantly in terms of the number of men admitted from the study group from 1.29 four to five years before closure to 0.74 in the three years after closure. This was especially true of admissions due to accidents (1.33 to 0.46) and diseases of the digestive system (4.53 to 1.03). For diseases of the circulatory system, particularly cardiovascular diseases, the relative risk increased from 0.8 to 1.60, and from 1.0 to 2.6 respectively. These changes in risk of illness after redundancy are probably a consequence of a change from the effects of a high risk work environment to the effects of psychosocial stresses such as job insecurity and unemployment."

  12. Long-Term Follow-up of Patent Ductus Arteriosus Closure with the Amplatzer Duct Occluder in Children

    Directory of Open Access Journals (Sweden)

    Mostafa Behjati-Ardakani

    2015-10-01

    Full Text Available Background: Transcatheter closure of patent ductus arteriosus (PDA has become an alternative treatment to surgery. We evaluated the long-term results of the transcatheter closure of PDA with the Amplatzer Duct Occluder (ADO in children.Methods: Between May 2004 and October 2012, 138 children with PDA (43 males and 95 females underwent transcatheter PDA closure. Clinical, electrocardiographic, echocardiographic, and hemodynamic data were assessed pre and postprocedurally and at follow-up.Results: The mean age of the patients at procedure was 3.53 ± 2.43 years (range = 1.1 to 9.5 years, mean weight was11.9±4.6 kg (range = 6 to 29 kg, median pulmonary end diameter of the PDA was 5 mm (range = 4 to 15 mm, and median diameter of the ADO was 8 mm (range = 6 to 16 mm. The mean follow-up time was 43.4 ± 23.5 months (range = 13.5 to98 months.The devices were successfully deployed in 136 (98.5% patients. Device embolization occurred in 2 patients, immediately in one patient and during the first postprocedural night in the other patient. The first patient had percutaneous device retrieval, followed by implantation of a larger device. The second patient had surgical device removal and PDA ligation. Immediately after device implantation, trivial to mild residual shunts were detected in 112 (80% patients; all the shunts, however, disappeared 24 hours after the procedure. One patient had left pulmonary artery stenosis with a gradient of 25 mm Hg at 24 hours', 40 mmHg at one month's, and 64 mmHg at 6 months' follow-up. There were no cases of late embolization, aortic obstruction, late hemolysis, infective endocarditis, or death.Conclusion: Transcatheter PDA closure with the ADO was safe and effective, with a high success rate at long-term follow-up.

  13. Heart failure after transvenous closure of atrial septal defect associated with atrial standstill and thiamine-responsive megaloblastic anemia.

    Science.gov (United States)

    Doğan, Vehbi; Senocak, Filiz; Orün, Utku Arman; Ceylan, Ozben

    2013-10-01

    Despite advances in device closure for atrial septal defect, post-closure heart failure remains a clinical problem in adult patients but is seen only rarely in children. An eight-year-old boy, who had been followed by a local pediatrician with the diagnosis of diabetes mellitus and congenital heart disease, was consulted to us for cardiac re-evaluation. Electrocardiography demonstrated absent P waves, and echocardiography revealed enlargement of the right ventricle and both atria and secundum atrial septal defect. With the diagnosis of atrial standstill, secundum atrial septal defect and thiamine-responsive megaloblastic anemia, acute heart failure developed after transvenous closure of the atrial septal defect, which improved dramatically with thiamine and supportive treatment.

  14. Transcatheter closure of perimembranous ventricular septal defects: single centre experience in China

    Institute of Scientific and Technical Information of China (English)

    LI Tian-chang; HU Da-yi; BIAN Hong; WANG Guo-hong; WANG Xian; ZHU Zheng-yan; XU Yu-yun

    2005-01-01

    @@ Ventricular septal defect (VSD) is one of the most common congenital heart malformation. As an isolated lesion, it accounts for 20%-30% of patients with congenital heart disease.1 Eighty percent of these defects are perimembranous involving the membranous septum and the adjacent area of muscular septum. At least 80% of these defects are small and close spontaneously,2,3 the larger defects often persist to cause significant shunt and right ventricular hypertension. Although conventional surgical repair of perimembranous ventricular septal defects (PMVSDs) is a safe, widely accepted procedure with negligible mortality. It is associated with morbidity, discomfort and a thoracotomy scar.1 As an alternative to surgery, a variety of devices for transcatheter closure of VSD have been developed. However, these devices were not specifically designed for this purpose and none has gained wide acceptance. Large delivery sheaths, inability to recapture and reposition, structural failure, dislodgement and embolization of the device, interference with the aortic valve resulting in aortic insufficiency and a high rate of residual shunting are the major limitations of the previously described techniques.2,3 The initial experiences with transcatheter closure of PMVSDs in patients with a new device that was especially designed for non-surgical occlusion of these defects, the Amplatzer asymmetric VSD occluder (AAVSDO, AGA Medical Co., USA) were encouraging.4-6 But the long-term results are not known.

  15. Photovoltaic device

    Energy Technology Data Exchange (ETDEWEB)

    Reese, Jason A; Keenihan, James R; Gaston, Ryan S; Kauffmann, Keith L; Langmaid, Joseph A; Lopez, Leonardo; Maak, Kevin D; Mills, Michael E; Ramesh, Narayan; Teli, Samar R

    2017-03-21

    The present invention is premised upon an improved photovoltaic device ("PV device"), more particularly to an improved photovoltaic device with a multilayered photovoltaic cell assembly and a body portion joined at an interface region and including an intermediate layer, at least one interconnecting structural member, relieving feature, unique component geometry, or any combination thereof.

  16. Photovoltaic device

    Science.gov (United States)

    Reese, Jason A.; Keenihan, James R.; Gaston, Ryan S.; Kauffmann, Keith L.; Langmaid, Joseph A.; Lopez, Leonardo C.; Maak, Kevin D.; Mills, Michael E.; Ramesh, Narayan; Teli, Samar R.

    2015-06-02

    The present invention is premised upon an improved photovoltaic device ("PV device"), more particularly to an improved photovoltaic device with a multilayered photovoltaic cell assembly and a body portion joined at an interface region and including an intermediate layer, at least one interconnecting structural member, relieving feature, unique component geometry, or any combination thereof.

  17. Concentration device

    DEFF Research Database (Denmark)

    2013-01-01

    A concentration device (2) for filter filtration concentration of particles (4) from a volume of a fluid (6). The concentration device (2) comprises a filter (8) configured to filter particles (4) of a predefined size in the volume of the fluid (6). The concentration device (2) comprises...

  18. Photovoltaic device

    Science.gov (United States)

    Reese, Jason A.; Keenihan, James R.; Gaston, Ryan S.; Kauffmann, Keith L.; Langmaid, Joseph A.; Lopez, Leonardo C.; Maak, Kevin D.; Mills, Michael E.; Ramesh, Narayan; Teli, Samar R.

    2015-09-01

    The present invention is premised upon an improved photovoltaic device ("PV device"), more particularly to an improved photovoltaic device (10) with a multilayered photovoltaic cell assembly (100) and a body portion (200) joined at an interface region (410) and including an intermediate layer (500), at least one interconnecting structural member (1500), relieving feature (2500), unique component geometry, or any combination thereof.

  19. Effects of notches on the order of flux-closure state formation in bi-rings by micromagnetic simulation

    Institute of Scientific and Technical Information of China (English)

    He Shu-Ting; Chang Shuang-Quan; Shi Hui-Gang

    2011-01-01

    The effects of the number and the location of notches on the formation of flux-closure states in bi-rings with fields applied in the x direction (i.e.,along the short axis direction of bi-rings) and y direction (i.e.,along the long axis direction of bi-rings) are investigated using micromagnetic simulation.For the bi-rings with one notch and the bi-rings with two notches symmetric about y axis,the order of flux-closure state formation in each ring can be controlled.But the flux-closure state forms simultaneously in each ring for the bi-rings with two notches symmetric about x axis.For the bi-rings with two notches that are symmetric neither about x axis nor about y axis,only one ring can form a fluxclosure state in the y-direction field and no flux-closure state can be found in rings in the x-direction field.Therefore,logic states can be defined by controlling the order of flux-closure state formation,which can be utilized in future logic devices.

  20. 3718-F Alkali Metal Treatment and Storage Facility Closure Plan

    Energy Technology Data Exchange (ETDEWEB)

    None

    1991-12-01

    Since 1987, Westinghouse Hanford Company has been a major contractor to the U.S. Department of Energy-Richland Operations Office and has served as co-operator of the 3718-F Alkali Metal Treatment and Storage Facility, the waste management unit addressed in this closure plan. The closure plan consists of a Part A Dangerous waste Permit Application and a RCRA Closure Plan. An explanation of the Part A Revision (Revision 1) submitted with this document is provided at the beginning of the Part A section. The closure plan consists of 9 chapters and 5 appendices. The chapters cover: introduction; facility description; process information; waste characteristics; groundwater; closure strategy and performance standards; closure activities; postclosure; and references.

  1. Mid-term Follow-up of the Transcatheter Closure of Perimembranous Ventricular Septal Defects in Children Using the Amplatzer

    Directory of Open Access Journals (Sweden)

    Mehdi Ghaderian

    2016-03-01

    Full Text Available Background: The ventricular septal defect (VSD is the most common form of congenital heart defects. The purpose of this study was to evaluate the results of the early complications and mid-term follow-up of the transcatheter closure of the VSD using the Amplatzer VSD Occluder.Methods: Between April 2012 and October 2013, 110 patients underwent the percutaneous closure of the perimembranous VSD. During the procedure, the size and type of the VSD were obtained via ventriculography. A device at least 2 mm larger than the VSD diameter measured via ventriculography was deployed. The size of the VSD, size of the Amplatzer, and device-size to VSD-size ratio were calculated. After the confirmation of the suitable position of the device via echocardiography and left ventriculography, the device was released. Follow-up evaluations were done at discharge as well as at 1, 6, and 12 months and yearly thereafter for the VSD occlusion and complete heart block.Results: The study population comprised 62 females and 48 males. The mean age and weight of the patients at procedure were 4.3 ± 5.6 years (range: 2 to 14 and 14.9 ± 10.8 kg (range: 10 to 43. The average device size was 7.0 ± 2.5 mm (range: 4 to 14. The VSD occlusion rate was 72.8% at the completion of the procedure and rose up to 99.0% during the follow-up. The most serious significant complication was complete atrioventricular block, which was seen in 2 patients. The mean follow-up duration was 10.9 ± 3.6 months.Conclusion: The transcatheter closure of the perimembranous VSD was a safe and effective treatment with excellent closure rates in our study population. This procedure had neither mortality nor serious complications. 

  2. Single trans-septal access technique for left atrial intracardiac echocardiography to guide left atrial appendage closure.

    Science.gov (United States)

    Aguirre, Daniel; Pincetti, Christian; Perez, Luis; Deck, Carlos; Alfaro, Mario; Vergara, Maria Jesus; Maluenda, Gabriel

    2017-08-24

    This registry aimed to describe the safety and feasibility of a single trans-septal (TS) access technique for left intracardiac echocardiography (ICE) guidance of left-atrial appendage (LAA) closure procedure. LAA closure is currently accepted as an alternative to oral anticoagulation (OAC) in patients with non-valvular atrial fibrillation (NVAF) who are at high-risk for bleeding. Currently, LAA closure procedure is typically performed under trans-esophageal echocardiogram (TEE) guidance. Although, ICE has the advantage of not requiring profound sedation/anesthesia, ICE-LAA imaging quality is often limited from the right atrium requiring double TS access. Twenty-two patients with NVAF underwent LAA closure using the Amplatzer Amulet™ device (St Jude Medical) under ICE guidance from the left atrium. The ICE AcuNav catheter (Biosense Webster) and the Amulet delivery sheath were advanced into the LA through single TS puncture technique. The population was predominately male (59.1%) with a mean age of 74 ± 9.3 years, at high-risk for stroke (mean CHADS2 score of 3.8 ± 1.1) and bleeding (mean HAS BLED score of 3.5 ± 1.3). The Amplatzer Amulet(TM) device was successfully implanted in all patients. No procedural related complications including device embolization were noted. No major cardiovascular events occurred and all patients were discharged alive. At 30-day follow-up all patients remained alive, free of ischemic stroke and with no residual leak or device thrombus on TEE. This initial experience suggests that LAA occlusion with the Amplatzer Amulet device using ICE guidance from the left atrium via a single trans-septal technique is feasible and safe. © 2017 Wiley Periodicals, Inc.

  3. A novel "in-situ tulip-bud deployment" method for transcatheter closure of secundum atrial septal defect.

    Science.gov (United States)

    Quek, Swee Chye; Wu, Wen Xia; Chan, Kit Yee; Ang, Patrick; Ho, Ting Fei; Yip, William

    2009-12-01

    We devised a new technique for interventional closure of atrial septal defect (ASD) using the Amplatzer Septal Occluder (ASO), and validated this by comparing it with a cohort using the conventional method. Transcatheter closure of ASD is a widely accepted modality of treatment. Although the outcome is good, there are occasional technical difficulties encountered. In this three-step technique, the device is protruded to form a "tulip bud." This "tulip bud" is then aligned adjacent to and along the plane of the ASD. The second step involves withdrawing the sheath in quick succession to deploy atrial discs over the septal defect. Finally, good placement of the occluder is checked before release. Twenty-seven consecutive patients (1.4-77.2 years of age, median = 15) underwent device closure by this method. Nineteen (70.4%) had a deficient aortic rim ( 0.05). The percentage of patients with aortic root deficiency was slightly higher in "tulip-bud" group compared to the conventional group (63.2% vs. 58.4%; p = 0.039). No complications were observed in either series. This is a promising new method to circumvent some of the difficulties associated with closure of large ASDs and deficient aortic rim.

  4. Mechanism and Etiology of Primary Chronic Angle Closure Glaucoma

    Institute of Scientific and Technical Information of China (English)

    1994-01-01

    The ocular anatomic features, pupil-blocking force, status of angle synechiae closure and positivity of provocative tests were compared between the primary chronic angle closure glaucoma (PCACG) and primary a-cute angle closure glaucoma (PAACG) by using ultrasonic biometry, computerized anterior ocular segment image processing technique, gonioscopy and provocative tests. The studies showed that the anterior chamber depth of PAACG was shallower than that of PCACG; the pupil-blocking force of PAACG was st...

  5. Rural pharmacy closures: implications for rural communities.

    Science.gov (United States)

    Todd, Kelli; Ullrich, Fred; Mueller, Keith

    2013-01-01

    Retail pharmacies provide essential services to residents of rural areas and serve many communities as the sole provider of pharmacist services. Losing the only retail pharmacy within a rural community (census designated city), and within a 10 mile radius based on driving distance ("sole community pharmacy"), may affect access to prescription and over-the-counter drugs and, in some cases, leave the community without proximate access to any clinical provider. This policy brief documents the closure of local retail pharmacies in which the pharmacist was the only clinical provider available in the community at the time the pharmacy closed. Characteristics of the community and the retail pharmacy are described. The findings may suggest future policy actions to minimize the risk or mitigate the negative consequences of pharmacy closures. Key Findings. (1) Between May 1, 2006, and October 31, 2010, 119 sole community pharmacies closed. (2) Of those 119 pharmacies, 31 were located in rural communities with no other health professionals or clinical providers. (3) In 16 states, at least 1 community lost a sole community retail pharmacy, and there was no other pharmacy within 10 miles (actual driving distance). (4) Of the 31 pharmacy closures in communities with no other providers, 17% were located in remote rural areas designated with a Rural-Urban Commuting Area (RUCA) score of 10 or higher. Such a score means that, on average, 60 minutes of travel time is required to reach an urbanized area, and 40 minutes is required to reach a large urban cluster of 20,000 population or more.

  6. Narrative Intelligibility and Closure in Interactive Systems

    DEFF Research Database (Denmark)

    Bruni, Luis Emilio; Baceviciute, Sarune

    2013-01-01

    ), which in turn can be seen as a function of Narrative Intelligibility. AAD can also be influenced by the intended or unintended level of abstractedness or didascalicity (i.e. figurativeness) of a given narrative. We define narrative intelligibility in complementarity with the related notion of Narrative...... Closure. We also make a distinction between the goals of the system and the goals of the narrative that it mediates, and consider the proposed parameters at two interrelated levels of analysis: the system level and the embedded narrative level, as the normative values and goals of these two levels should...

  7. 100-N Area underground storage tank closures

    Energy Technology Data Exchange (ETDEWEB)

    Rowley, C.A.

    1993-08-01

    This report describes the removal/characterization actions concerning underground storage tanks (UST) at the 100-N Area. Included are 105-N-LFT, 182-N-1-DT, 182-N-2-DT, 182-N-3-DT, 100-N-SS-27, and 100-N-SS-28. The text of this report gives a summary of remedial activities. In addition, correspondence relating to UST closures can be found in Appendix B. Appendix C contains copies of Unusual Occurrence Reports, and validated sampling data results comprise Appendix D.

  8. Defense Base Closure and Realignment Commission

    Science.gov (United States)

    1993-01-01

    international responsibilities with more limited resources. ýeS~ectfully yours , im Courter k,"Chairman CAPT Peter 𔃽owman, USN (Ret) C mBeverly Byr bea Cox...sub tania and, the forc tr- a clear decline in the period 1995-1999. Thus, turc plan and fial criteria and, therefore, theas te wrk clnes theexcss...restoration (cleanup) costs in the cost of closure, on the status of this request to the 1995 since DoD is obligated to clean up bases Commission. regardless

  9. Post Closure Safety of the Morsleben Repository

    Energy Technology Data Exchange (ETDEWEB)

    Preuss, J.; Eilers, G.; Mauke, R.; Moeller-Hoeppe, N.; Engelhardt, H.-J.; Kreienmeyer, M.; Lerch, C.; Schrimpf, C.

    2002-02-26

    After the completion of detailed studies of the suitability the twin-mine Bartensleben-Marie, situated in the Federal State of Saxony-Anhalt (Germany), was chosen in 1970 for the disposal of low and medium level radioactive waste. The waste emplacement started in 1978 in rock cavities at the mine's fourth level, some 500 m below the surface. Until the end of the operational phase in 1998 in total about 36,800 m{sup 3} of radioactive waste was disposed of. The Morsleben LLW/ILW repository (ERAM) is now under licensing for closure. After completing the licensing procedure the repository will be sealed and backfilled to exclude any undue future impact onto man or the environment. The main safety objective is to protect the biosphere from the harmful effects of the disposed radionuclides. Furthermore, classical or conventional requirements call for ruling out or minimizing other unfavorable environmental effects. The ERAM is an abandoned rock salt and potash mine. As a consequence it has a big void volume, however small parts of the cavities are backfilled with crushed salt rocks. Other goals of the closure concept are therefore a long-term stabilization of the cavities to prevent a dipping or buckling of the ground surface. In addition, groundwater protection shall be assured. For the sealing of the repository a closure concept was developed to ensure compliance with the safety protection objectives. The concept anticipates the backfilling of the cavities with hydraulically setting backfill materials (salt concretes). The reduction of the remaining void volume in the mine causes in the case of brine intrusions a limitation of the leaching processes of the exposed potash seams. However, during the setting process the hydration heat of the concrete will lead to an increase of the temperature and hence to thermally induced stresses of the concrete and the surrounding rocks. Therefore, the influence of these stresses and deformations on the stability of the salt body

  10. Multiple coil closure of isolated aortopulmonary collateral

    Directory of Open Access Journals (Sweden)

    Padhi Sumanta

    2010-01-01

    Full Text Available A 7-month-old girl was diagnosed to have large aortopulmonary collateral during evaluation for congestive heart failure. There was no other evidence of cardiopulmonary disease. The collateral was successfully closed with multiple coils delivered sequentially. We describe the issues associated during closure of the aortopulmonary collateral in this case. To the best of our knowledge, this is the first reported case of large aortopulmonary collateral presenting with heart failure in an otherwise structurally normal heart that was closed successfully with multiple coils delivered sequentially.

  11. Double-wire sternal closure technique in bovine animal models for total artificial heart implant.

    Science.gov (United States)

    Karimov, Jamshid H; Sunagawa, Gengo; Golding, Leonard A R; Moazami, Nader; Fukamachi, Kiyotaka

    2015-08-01

    In vivo preclinical testing of mechanical circulatory devices requires large animal models that provide reliable physiological and hemodynamic conditions by which to test the device and investigate design and development strategies. Large bovine species are commonly used for mechanical circulatory support device research. The animals used for chronic in vivo support require high-quality care and excellent surgical techniques as well as advanced methods of postoperative care. These techniques are constantly being updated and new methods are emerging.We report results of our double steel-wire closure technique in large bovine models used for Cleveland Clinic's continuous-flow total artificial heart development program. This is the first report of double-wire sternal fixation used in large bovine models.

  12. U.S. Small Business HUBZone Base Closure Areas

    Data.gov (United States)

    Small Business Administration — HUBZone Qualitified Base Closure Areas - the lands within the boundaries of a military installation that was closed through a privatization process under the Federal...

  13. Effect of crack surface geometry on fatigue crack closure

    Energy Technology Data Exchange (ETDEWEB)

    Drury, W.J. [P and L Technologies, Inc., Atlanta, GA (United States); Gokhale, A.M. [Georgia Inst. of Tech., Atlanta, GA (United States). School of Materials Science and Engineering; Antolovich, S.D. [Washington State Univ., Pullman, WA (United States). School of Mechanical and Materials Engineering

    1995-10-01

    The geometry of crack faces often plays a critical role in reducing crack extension forces when crack closure occurs during fatigue crack growth. Most previous studies of fatigue crack closure are concerned with mechanical measure of closure as related to the crack growth rate; very little attention has been given to the geometry of the crack surfaces. The objective is to identify those aspects of crack surface geometry that are important in the closure process, to develop quantitative fractographic techniques to estimate such attributes in a statistically significant and robust manner, and to correlate them to the physical process of crack closure. For this purpose, fatigue crack propagation experiments were performed on a Ni-base superalloy and crack growth rates and crack closure loads were measured. Digital image profilometry and software-based analysis techniques were used for statistically reliable and detailed quantitative characterization of fatigue crack profiles. It is shown that the dimensionless, scale-independent attributes, such a height-to-width ratio of asperities, fractal dimensions, dimensionless roughness parameters, etc., do not represent the aspects of crack geometry that are of primary importance in the crack closure phenomena. Furthermore, it is shown that the scale-dependent characteristics, such as average asperity height, do represent the aspects of crack geometry that play an interactive role in the closure process. These observations have implications concerning the validity of geometry-dependent, closure-based models for fatigue crack growth.

  14. Role of management devices in enacting strategy

    DEFF Research Database (Denmark)

    Harritz, Daniel

    2016-01-01

    Purpose - This study illustrates the role of management devices in enacting strategy and strategic decisions, resulting in the development of a Shared Service Centre (SSC) in a Danish municipality. It shows how devices interact in defending, rejecting and reframing strategy, leading to the closure...... of the SSC to pave the way for new strategic ideas. Design/methodology/approach - It employs a longitudinal case-based approach, which draws on actor-network theory, particularly Callon’s (1998) notions of framing and overflowing. These notions help describe strategic events and processes by highlighting...... the active role of non-human entities, such as management devices, in enacting and reformulating strategy. Findings - Different devices have become key actants in shaping and formulating the new strategy in the municipality and the strategic decision to construct a SSC. However, different devices mobilise...

  15. A New Surgical Technique for Closure of Pilonidal Sinus Defects: Triangular Closure Technique

    Science.gov (United States)

    Mutaf, Mehmet; Temel, Metin; Koç, Mustafa Nihat

    2017-01-01

    Background We present a clinical experience with a new local flap procedure, namely the triangular closure technique, for reconstruction of sacrococcygeal skin defects resulting from excision of the pilonidal sinus. Material/Methods In this technique, the defect is surgically converted to a triangle in shape. Then, the triangular defect is closed by transposition of 2 skin flaps designed in an unequal z-plasty manner. Over 6 years, this technique has been used for closure of defects of chronic pilonidal sinus disease in 27 patients (6 females, 21 males). The size of the defect ranged between 3.5 cm and 12 cm in dimension. Results A tension-free defect closure was obtained in all patients. All flaps except one healed with no complications. A mean follow-up of 3.62±1.77 months revealed aesthetically and functionally acceptable results with the obliteration of the natal cleft in all patients. No recurrence was observed in the follow-up period. Conclusions The triangular closure technique was found to be a useful technique for the treatment of pilonidal sinus with favorable results regarding the time before return to work. PMID:28238003

  16. Transcatheter closure of patent ductus arteriosus: Evaluating the effect of the learning curve on the outcome

    Directory of Open Access Journals (Sweden)

    Azhar Ahmad

    2009-01-01

    Full Text Available Background and Objectives : Initial experience with transcatheter closure of patent ductus arteriosus (PDA using detachable coils and Amplatzer duct occluder devices is reported. We evaluated the outcome, complications, and influence of the learning curve, and also assessed the need of surgical backup for such interventional procedures. Methods: From January 2000 to December 2004, 121 patients underwent transcatheter closure of PDA. Aortic angiogram was performed to evaluate the size, position, and shape of the duct for appropriately choosing the occluder device type and size. A second aortic angiogram was performed 10 minutes after device deployment. Echocardiography was repeated at intervals of 24 hours, then at 1, 3, and 6 months after the procedure to assess complications. Stepwise multiple regression analysis was used to assess the role of experience in improving the outcome of the procedure. Results: Of 121 cases, four patients had pulmonary artery embolization of the occluder device which was successfully retrieved in the catheterization laboratory, while two others had embolization that required surgical intervention. Four patients had temporary residual leak, nine had protrusion of the device into the aorta without significant Doppler pressure gradient or hemolysis on follow-up, and five had partial hemodynamically insignificant obstruction to the left pulmonary artery. Statistical analysis showed that the effect of the learning curve and experience was responsible for 93% improvement in the procedural outcome over the five-year study period. Conclusion: Transcatheter occlusion of PDA is safe and effective alternative to surgery. Complications occurred in those with unfavorable duct anatomy and with the use of multiple coils. Surgical backup was important for such interventional procedures. Experience played a major role in the proper choice of device type and size which greatly influenced the outcome of the procedure.

  17. Closure Plan for the Area 3 Radioactive Waste Management Site at the Nevada Test Site

    Energy Technology Data Exchange (ETDEWEB)

    NSTec Environmental Management

    2007-09-01

    The Area 3 Radioactive Waste Management Site (RMWS) at the Nevada Test Site (NTS) is managed and operated by National Security Technologies, LLC (NSTec) for the U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office (NNSA/NSO). This document is the first update of the interim closure plan for the Area 3 RWMS, which was presented in the Integrated Closure and Monitoring Plan (ICMP) (DOE, 2005). The format and content of this plan follows the Format and Content Guide for U.S. Department of Energy Low-Level Waste Disposal Facility Closure Plans (DOE, 1999a). The major updates to the plan include a new closure date, updated closure inventory, the new institutional control policy, and the Title II engineering cover design. The plan identifies the assumptions and regulatory requirements, describes the disposal sites and the physical environment in which they are located, presents the design of the closure cover, and defines the approach and schedule for both closing and monitoring the site. The Area 3 RWMS accepts low-level waste (LLW) from across the DOE Complex in compliance with the NTS Waste Acceptance Criteria (NNSA/NSO, 2006). The Area 3 RWMS accepts both packaged and unpackaged unclassified bulk LLW for disposal in subsidence craters that resulted from deep underground tests of nuclear devices in the early 1960s. The Area 3 RWMS covers 48 hectares (119 acres) and comprises seven subsidence craters--U-3ax, U-3bl, U-3ah, U-3at, U-3bh, U-3az, and U-3bg. The area between craters U-3ax and U-3bl was excavated to form one large disposal unit (U-3ax/bl); the area between craters U-3ah and U-3at was also excavated to form another large disposal unit (U-3ah/at). Waste unit U-3ax/bl is closed; waste units U-3ah/at and U-3bh are active; and the remaining craters, although currently undeveloped, are available for disposal of waste if required. This plan specifically addresses the closure of the U-3ah/at and the U-3bh LLW units. A final closure

  18. Microfluidic Device

    Science.gov (United States)

    Tai, Yu-Chong (Inventor); Zheng, Siyang (Inventor); Lin, Jeffrey Chun-Hui (Inventor); Kasdan, Harvey L. (Inventor)

    2017-01-01

    Described herein are particular embodiments relating to a microfluidic device that may be utilized for cell sensing, counting, and/or sorting. Particular aspects relate to a microfabricated device that is capable of differentiating single cell types from dense cell populations. One particular embodiment relates a device and methods of using the same for sensing, counting, and/or sorting leukocytes from whole, undiluted blood samples.

  19. IT Services Availability during the CERN Annual Closure 2005

    CERN Multimedia

    2005-01-01

    Mail, CERN Windows (NICE), Web services, LXPLUS, LXBATCH, AFS, the automated tape devices, Castor, CDS Search, Submit and Agenda, InDiCo, EDMS (in collaboration with TS Department), Campus Network, Remedy, and Security services will be available during the CERN annual closure. All production databases will remain available (but not development databases such as devdb and devdb10). Problems occuring on scheduled services should be addressed within about half a day, except around Christmas Eve and Christmas Day (24 and 25 December) and New Year's Eve and New Year's Day (31 December and 1st January). As far as administrative computings services are concerned, ERT (Electronic Recruitment Tool) and PPT (Project Progress Tracking) for EGEE will be the only operational services; all other AIS applications such as EDH, CET, HRT, etc. will be unavailable from Wednesday 21/12 12:00 to Thursday 5/01/2005 8:00. The CERN LCG Production Services will be run on a 'best effort” basis. All other services (such as the ...

  20. The impact of operational closure and reflection on juncture systems

    Directory of Open Access Journals (Sweden)

    Benjamin Kuch

    2016-11-01

    Full Text Available Business organisations can be seen as social systems encompassing multiple scales. The more functionally differentiated a system landscape becomes the higher the need to coordinate different processes between these systems is. This helps to develop sound business strategies supporting the identification of synergy potentials. Induced by turbulent markets, especially multinational enterprises have to continuously adapt their strategies and introduce new junctures between parts of their organisations. The current article contributes to the effective management of those junctures whilst adopting a systems theory perspective. Novel insights on the coordination of strategic change processes, which are most relevant to businesses in order to implement new strategies, are derived from a system dynamics model. They are subsequently applied to a single case study in the medical device industry for the purpose of discussing implications for international enterprises. It is shown how the concepts of operational closure and reflection impact on the junctures between complex social systems. Therefore, it is argued that the analysis of the systemic communication patterns should be considered an integral part of any strategic change process within multinational enterprises. Moreover, the findings are generic enough to be transferred to the regional level as well. The presented approach on the coordination of complex social systems provides valuable impulses, even if the involved systems come from the political or scientific sector. Hence, the investigation of mixed systems coordination is suggested to be part of a future research agenda.

  1. Distributed Programming via Safe Closure Passing

    Directory of Open Access Journals (Sweden)

    Philipp Haller

    2016-02-01

    Full Text Available Programming systems incorporating aspects of functional programming, e.g., higher-order functions, are becoming increasingly popular for large-scale distributed programming. New frameworks such as Apache Spark leverage functional techniques to provide high-level, declarative APIs for in-memory data analytics, often outperforming traditional "big data" frameworks like Hadoop MapReduce. However, widely-used programming models remain rather ad-hoc; aspects such as implementation trade-offs, static typing, and semantics are not yet well-understood. We present a new asynchronous programming model that has at its core several principles facilitating functional processing of distributed data. The emphasis of our model is on simplicity, performance, and expressiveness. The primary means of communication is by passing functions (closures to distributed, immutable data. To ensure safe and efficient distribution of closures, our model leverages both syntactic and type-based restrictions. We report on a prototype implementation in Scala. Finally, we present preliminary experimental results evaluating the performance impact of a static, type-based optimization of serialization.

  2. On closure parameter estimation in chaotic systems

    Directory of Open Access Journals (Sweden)

    J. Hakkarainen

    2012-02-01

    Full Text Available Many dynamical models, such as numerical weather prediction and climate models, contain so called closure parameters. These parameters usually appear in physical parameterizations of sub-grid scale processes, and they act as "tuning handles" of the models. Currently, the values of these parameters are specified mostly manually, but the increasing complexity of the models calls for more algorithmic ways to perform the tuning. Traditionally, parameters of dynamical systems are estimated by directly comparing the model simulations to observed data using, for instance, a least squares approach. However, if the models are chaotic, the classical approach can be ineffective, since small errors in the initial conditions can lead to large, unpredictable deviations from the observations. In this paper, we study numerical methods available for estimating closure parameters in chaotic models. We discuss three techniques: off-line likelihood calculations using filtering methods, the state augmentation method, and the approach that utilizes summary statistics from long model simulations. The properties of the methods are studied using a modified version of the Lorenz 95 system, where the effect of fast variables are described using a simple parameterization.

  3. Three-dimensional Transesophageal Echocardiography-guided Transcathetar Closure of Ruptured Noncoronary Sinus of Valsalva Aneurysm

    Science.gov (United States)

    Kumar, G Anil; Parimala, P S; Jayaranganath, M; Jagadeesh, A M

    2017-01-01

    Sinus of Valsalva aneurysm accounts for only 1% of congenital cardiac anomalies. Sinus of Valsalva aneurysm can cause aortic insufficiency, coronary artery flow compromise, cardiac arrhythmia, or aneurysm rupture. Three-dimensional transesophageal echocardiography (3DTEE) represents an adjunctive tool to demonstrate the ruptured sinus of Valsalva with better delineation. We present an adult patient with rupture of noncoronary sinus of Valsalva aneurysm into the right atrium (RA). 3DTEE accurately delineated the site of rupture into the RA and showed the exact size and shape of the defect, which helped in the successful transcatheter closure of the defect with a duct occluder device. PMID:28074828

  4. Successful Treatment of Anterior Tracheal Necrosis after Total Thyroidectomy Using Vacuum-Assisted Closure Therapy

    Directory of Open Access Journals (Sweden)

    Grégory Philippe

    2012-01-01

    Full Text Available Total thyroidectomy involving the adjacent structures of the trachea can cause tracheal damage such as early tracheal necrosis. The authors describe the first case of anterior tracheal necrosis following total thyroidectomy treated using vacuum-assisted closure device. After two weeks of VAC  therapy, there was no evidence of ongoing infection and the trachea was partially closed around a tracheotomy cannula, removed after 3 months. The use of a VAC  therapy to reduce and close the tracheal rent and to create a rapid granulation tissue over tracheal structure appeared as a good opportunity after anterior tracheal necrosis.

  5. Transcatheter closure of a pulmonary arteriovenous malformation in a patient with hereditary hemorrhagic telangiectasia.

    Science.gov (United States)

    Parker, Christopher; Rousan, Talla A; Abu-Fadel, Mazen

    2015-07-01

    Pulmonary arteriovenous malformations (PAVM) are rare pulmonary vascular anomalies. Over 50 % of the cases are associated with hereditary hemorrhagic telangiectasia or Osler-Weber-Rendu Syndrome. Untreated PAVMs progressively enlarge and can cause significant right-to-left shunting. Surgical- and catheter-based approaches have been used in the management of PAVM. We report a case of a 74-year-old man who presented with dyspnea and hypoxia and was found to have a large right-sided PAVM. He underwent percutaneous closure of the PAVM with an Amplatzer device with significant improvement of his symptoms.

  6. Noise-optimised operation of vehicle power closures; Geraeuschoptimierte Ansteuerung von Kfz-Schliesssystemen

    Energy Technology Data Exchange (ETDEWEB)

    Schulter, Wolfgang [Hochschule Ravensburg-Weingarten (Germany). Fakultaet Elektrotechnik und Informatik; Vetter, Juergen [Continental, Regensburg (Germany). Bereich Body and Security/Power Closures

    2013-03-15

    The operation of electric power closures, such as electric window lifters, inevitably generates noise which is often perceived as disturbing. This type of insulation is mainly suitable for damping the higher frequency components within the noise spectrum. Designing such passive insulation for lower frequencies results in large, bulky and expensive devices. This paper explains how part of the noise originates from the drive motor. The example of a DC motor serves to demonstrate that a considerable share of the noise can be traced back to its commutation. Using optimised commutation in addition to design measures allows to refine the electronic motor control in order to make the motor run more smoothly.

  7. Innovation in intervention : new devices in interventional cardiology

    NARCIS (Netherlands)

    Van den Branden, B.J.L.

    2011-01-01

    This thesis reports on the application of several new devices for percutaneous treatment of structural heart disease. A patent foramen ovale (PFO) is a tunnellike communication between the right and the left atrium and has been associated with the occurrence of cryptogenic stroke. PFO closure has pr

  8. Concurrent transcatheter closure of an apical muscular ventricular septal defect and a patent ductus arteriosus in a child with severe hyperkinetic pulmonary hypertension.

    Science.gov (United States)

    Joseph, G; Muthunayagam, J V; Mandalay, A

    2003-01-01

    Definitive treatment of congenital apical muscular ventricular septal defect (VSD) with large left-to-right shunt, severe pulmonary hypertension, and major associated lesions such as patent ductus arteriosus (PDA) has so far been possible only by surgery that has significant attendant morbidity and mortality [2]. Transcatheter device closure of both shunt lesions, if feasible, is a potentially simpler and safer alternative to surgery.

  9. Early Canadian Multicenter Experience With WATCHMAN for Percutaneous Left Atrial Appendage Closure.

    Science.gov (United States)

    Saw, Jacqueline; Fahmy, Peter; Azzalini, Lorenzo; Marquis, Jean-Francois; Hibbert, Benjamin; Morillo, Carlos; Carrizo, Aldo; Ibrahim, Reda

    2017-04-01

    There are limited data with WATCHMAN (Boston Scientific Corporation, Natick, MA, USA) for left atrial appendage (LAA) closure in patients with nonvalvular atrial fibrillation (AF) and contraindications to anticoagulation. The purpose of this study was to evaluate the safety and efficacy of WATCHMAN in our early Canadian experience. We report our pooled consecutive series of patients who underwent WATCHMAN implantation at four major Canadian centers. Indications for LAA closure were CHADS2 ≥ 1 or CHA2 DS2 -VASc ≥ 2, and contraindication/intolerance to or failure on anticoagulation. Follow-up imaging was typically performed 1-6 months postprocedure. One hundred and six patients underwent LAA closure with WATCHMAN from May 2013 to October 2015. The mean age was 74.8 ± 7.7, mean CHADS2 score was 2.8 ± 1.2, CHA2 DS2 -VASc score was 4.3 ± 1.5, and HASBLED score was 3.2 ± 1.2. Permanent AF was present in 67.9% and paroxysmal AF in 32.1%. Indications for LAA closure were prior bleeding 89.6% (87 major bleeding and 8 minor bleeding), 9.4% were deemed high risk for bleeding, and 0.9% with recurrent strokes on warfarin. Procedural success was 97.2% (103 of 106), with one device embolization (snared percutaneously), one implant failure due to inadequate LAA depth, and one cardiac perforation requiring surgical repair before WATCHMAN implantation. The composite major safety event-rate was 1.9% (1 death and 1 device embolization). Mean hospital stay was 1.8 ± 4.7 days. Antithrombotic therapy postimplant included dual antiplatelet therapy in 76 of 103 (73.8%). Mean follow-up was 210 ± 182 days; there were two transient ischemic attacks, with estimated 66% reduction in thromboembolic events relative to CHADS2 predicted risk. In our early Canadian experience, WATCHMAN for LAA closure in patients contraindicated to anticoagulation appeared safe and effective. © 2017 Wiley Periodicals, Inc.

  10. 77 FR 55895 - Permanent Closure of Cincinnati Blue Ash Airport

    Science.gov (United States)

    2012-09-11

    ... Federal Aviation Administration Permanent Closure of Cincinnati Blue Ash Airport AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Notice of permanent closure of Cincinnati Blue Ash Airport (ISZ). SUMMARY: The... Cincinnati advising that on August 29, 2012, it was permanently closing Cincinnati Blue Ash Airport...

  11. The use of paper tape in wound closures.

    Science.gov (United States)

    Danto, L A; Albertazzi, V J; Elliott, T E; Love, F G

    1986-12-01

    The techniques described using paper tape in wound closure have been found to be cosmetically equal to or better than other forms of wound closure. Paper tape provides better support, is more versatile and care free, while being easier to use and less expensive than Steri Strips.

  12. Managing waste exports when closure risks are endogenous

    OpenAIRE

    Stähler, Frank; Michaelis, Peter

    1993-01-01

    This paper provides a rationale for taxing waste exports when closure risks are endogenous in that they depend on the importing country's accumulated stock of waste. The paper shows that the optimal time path of waste exports requires a progressively increasing tax rate which even surmounts a Hotelling tax which tackles the problem by evaluating the expected closure stock.

  13. 30 CFR 57.4603 - Closure of valves.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Closure of valves. 57.4603 Section 57.4603... Control Welding/cutting/compressed Gases § 57.4603 Closure of valves. To prevent accidental release of... or manifold system valves shall be closed when— (a) The cylinders are moved; (b) The torch and...

  14. 30 CFR 56.4603 - Closure of valves.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Closure of valves. 56.4603 Section 56.4603... Control Welding/cutting/compressed Gases § 56.4603 Closure of valves. To prevent accidental release of... or manifold system valves shall be closed when— (a) The cylinders are moved; (b) The torch and...

  15. On the normality of orbit closures which are hypersurfaces

    Indian Academy of Sciences (India)

    Nguyen Quang Loc

    2016-02-01

    Let be a quiver representation with non-zero admissible annihilator. In this paper, we prove the normality of the orbit closure $\\bar{\\mathcal{O}}_{N}$ when it is a hypersurface. The result thus gives new examples of normal orbit closures of quiver representations.

  16. Biomechanics Strategies for Space Closure in Deep Overbite

    Directory of Open Access Journals (Sweden)

    Harryanto Wijaya

    2013-07-01

    Full Text Available Space closure is an interesting aspect of orthodontic treatment related to principles of biomechanics. It should be tailored individually based on patient’s diagnosis and treatment plan. Understanding the space closure biomechanics basis leads to achieve the desired treatment objective. Overbite deepening and losing posterior anchorage are the two most common unwanted side effects in space closure. Conventionally, correction of overbite must be done before space closure resulted in longer treatment. Application of proper space closure biomechanics strategies is necessary to achieve the desired treatment outcome. This cases report aimed to show the space closure biomechanics strategies that effectively control the overbite as well as posterior anchorage in deep overbite patients without increasing treatment time. Two patients who presented with class II division 1 malocclusion were treated with fixed orthodontic appliance. The primary strategies included extraction space closure on segmented arch that employed two-step space closure, namely single canine retraction simultaneously with incisors intrusion followed by enmasse retraction of four incisors by using differential moment concept. These strategies successfully closed the space, corrected deep overbite and controlled posterior anchorage simultaneously so that the treatment time was shortened. Biomechanics strategies that utilized were effective to achieve the desired treatment outcome.

  17. Localization of Tight Closure in Two-Dimensional Rings

    Indian Academy of Sciences (India)

    Kamran Divaani-Aazar; Massoud Tousi

    2005-02-01

    It is shown that tight closure commutes with localization in any two-dimensional ring of prime characteristic if either is a Nagata ring or possesses a weak test element. Moreover, it is proved that tight closure commutes with localization at height one prime ideals in any ring of prime characteristic.

  18. 40 CFR 267.142 - Cost estimate for closure.

    Science.gov (United States)

    2010-07-01

    ... dollars, or by using an inflation factor derived from the most recent Implicit Price Deflator for Gross... active life of the facility, the owner or operator must adjust the closure cost estimate for inflation... closure cost estimate must be updated for inflation within 30 days after the close of the firm's fiscal...

  19. WASTE PACKAGE OPERATIONS FY99 CLOSURE METHODS REPORT

    Energy Technology Data Exchange (ETDEWEB)

    M. C. Knapp

    1999-09-23

    The waste package (WP) closure weld development task is part of a larger engineering development program to develop waste package designs. The purpose of the larger waste package engineering development program is to develop nuclear waste package fabrication and closure methods that the Nuclear Regulatory Commission will find acceptable and will license for disposal of spent nuclear fuel (SNF), non-fuel components, and vitrified high-level waste within a Monitored Geologic Repository (MGR). Within the WP closure development program are several major development tasks, which, in turn, are divided into subtasks. The major tasks include: WP fabrication development, WP closure weld development, nondestructive examination (NDE) development, and remote in-service inspection development. The purpose of this report is to present the objectives, technical information, and work scope relating to the WP closure weld development.and NDE tasks and subtasks and to report results of the closure weld and NDE development programs for fiscal year 1999 (FY-99). The objective of the FY-99 WP closure weld development task was to develop requirements for closure weld surface and volumetric NDE performance demonstrations, investigate alternative NDE inspection techniques, and develop specifications for welding, NDE, and handling system integration. In addition, objectives included fabricating several flat plate mock-ups that could be used for NDE development, stress relief peening, corrosion testing, and residual stress testing.

  20. Guinea pig ductus arteriosus. II - Irreversible closure after birth.

    Science.gov (United States)

    Fay, F. S.; Cooke, P. H.

    1972-01-01

    To investigate the mechanism underlying irreversibility of ductal closure after birth, studies were undertaken to determine the exact time course for the onset of irreversible closure of the guinea pig ductus arteriosus. Parallel studies of the reactivity of ductal smooth muscle to oxygen and studies of the postpartum cellular changes within the vessel were also carried out.

  1. Surgical repair of true left ventricular aneurysm in an infant: a rare complication after unsuccessful perventricular VSD closure.

    Science.gov (United States)

    Ozyilmaz, Isa; Saygi, Murat; Yildiz, Okan; Erek, Ersin; Guzeltas, Alper

    2014-10-01

    A 2.5-month-old female patient presented for closure of a ventricular septal defect (VSD). Transthoracic echocardiography showed a large muscular ventricular septal defect. After perventricular closure of the defect was performed with an Amplatzer muscular VSD occluder, peroperative transesophageal echocardiography revealed that the device had been implanted in the wrong area of the ventricular septum. The device was retrieved and a large mid-muscular defect with extension to the outlet septum was closed with a patch of Dacron which was secured with 5-0 sutures. A perforation in the ventricular septum due to attempted perventricular device delivery was seen, and it was repaired primarily. In the eighth month of follow-up, transthoracic echocardiography revealed an aneurysm in the posterior wall of the left ventricle. The patient's electrocardiogram showed pathological Q waves and ST-segment elevation in leads DII, DIII, and aVF consistent with subacute inferior myocardial infarction. At subsequent surgery, this was found to be a true aneurysm, located in area of distribution of the obtuse marginal branch of the left circumflex coronary artery in the posterior wall of the left ventricle. The aneurysm was closed off using a Dacron patch, and the sac was resected. Development of a true aneurysm is a rare but important complication of attempted perventricular VSD closure.

  2. The hybrid perventricular closure of apical muscular ventricular septal defect with Amplatzer duct occluder

    Directory of Open Access Journals (Sweden)

    Soo Jin Kim

    2013-04-01

    Full Text Available &lt;b&gt;Purpose:&lt;/b&gt; Apical muscular ventricular septal defects (MVSDs, especially in small infants, can be difficult to manage using surgical and percutaneous closure. An intraoperative perventricular procedure is a good option for closing apical MVSDs in small children with or without associated cardiac anomalies.We evaluated the results of hybrid perventricular closure of apical MVSDs performed using an Amplatzer duct occluder (ADO. &lt;b&gt;Methods:&lt;/b&gt; We retrospectively reviewed the medical records of 5 patients who underwent hybrid perventricular closure of MVSDs with ADOs, from March 2006 to May 2011. The median patient age at the time of the procedure was 12 months (range, 25 days to 25 months, and the median body weight was 9.1 kg (range, 4.3 to 15 kg. Two patients had multiple ventricular septal defects (VSDs; additional perimembranous VSD in 1 patient and multiple MVSDs in the other and 3 patients had associated cardiac anomalies; complete transposition of the great arteries in 1 patient and an atrial septal defect in 2 patients. All the procedures were performed on beating hearts, exception in 1 case. The ADO selected for the aortic side was at least 1 to 2 mm larger than the largest VSD in the left ventricle side. &lt;b&gt;Results:&lt;/b&gt; The procedure was successful in all patients and each device was well positioned. During the median follow-up of 2.4 years, a small residual VSD was noted in 2 patients who had multiple VSDs and no leakage was seen in the other 3 patients. &lt;b&gt;Conclusion:&lt;/b&gt; Perventricular closure of MVSD with an ADO is a good option for patients with apical MVSD. However, careful manipulation is important, especially in the case of small infants.

  3. Left Atrial Appendage Closure Guided by Integrated Echocardiography and Fluoroscopy Imaging Reduces Radiation Exposure.

    Directory of Open Access Journals (Sweden)

    Christiane Jungen

    Full Text Available To investigate whether percutaneous left atrial appendage (LAA closure guided by automated real-time integration of 2D-/3D-transesophageal echocardiography (TEE and fluoroscopy imaging results in decreased radiation exposure.In this open-label single-center study LAA closure (AmplatzerTM Cardiac Plug was performed in 34 consecutive patients (8 women; 73.1±8.5 years with (n = 17, EN+ or without (n = 17, EN- integrated echocardiography/fluoroscopy imaging guidance (EchoNavigator® [EN]; Philips Healthcare. There were no significant differences in baseline characteristics between both groups. Successful LAA closure was documented in all patients. Radiation dose was reduced in the EN+ group about 52% (EN+: 48.5±30.7 vs. EN-: 93.9±64.4 Gy/cm2; p = 0.01. Corresponding to the radiation dose fluoroscopy time was reduced (EN+: 16.7±7 vs. EN-: 24.0±11.4 min; p = 0.035. These advantages were not at the cost of increased procedure time (89.6±28.8 vs. 90.1±30.2 min; p = 0.96 or periprocedural complications. Contrast media amount was comparable between both groups (172.3±92.7 vs. 197.5±127.8 ml; p = 0.53. During short-term follow-up of at least 3 months (mean: 8.1±5.9 months no device-related events occurred.Automated real-time integration of echocardiography and fluoroscopy can be incorporated into procedural work-flow of percutaneous left atrial appendage closure without prolonging procedure time. This approach results in a relevant reduction of radiation exposure.ClinicalTrials.gov NCT01262508.

  4. Fatigue Crack Closure Analysis Using Digital Image Correlation

    Science.gov (United States)

    Leser, William P.; Newman, John A.; Johnston, William M.

    2010-01-01

    Fatigue crack closure during crack growth testing is analyzed in order to evaluate the critieria of ASTM Standard E647 for measurement of fatigue crack growth rates. Of specific concern is remote closure, which occurs away from the crack tip and is a product of the load history during crack-driving-force-reduction fatigue crack growth testing. Crack closure behavior is characterized using relative displacements determined from a series of high-magnification digital images acquired as the crack is loaded. Changes in the relative displacements of features on opposite sides of the crack are used to generate crack closure data as a function of crack wake position. For the results presented in this paper, remote closure did not affect fatigue crack growth rate measurements when ASTM Standard E647 was strictly followed and only became a problem when testing parameters (e.g., load shed rate, initial crack driving force, etc.) greatly exceeded the guidelines of the accepted standard.

  5. Experience with percutaneous closure of ductus arteriosus using the Amplatzer duct occluder in 243 consecutive patients and long-term results-A single centre study

    Directory of Open Access Journals (Sweden)

    Mostafa Behjati-Ardakani

    2014-01-01

    Full Text Available Background: Percutaneous closure of patent ductus arteriosus (PDA with Amplatzer duct occluder (ADO has become increasingly popular in many cardiovascular centres. This study analysed the long-term results of percutaneous closure of PDA with ADO in a single centre. Materials and Methods: Between May 2004 and January 2013, 243 patients with median age of 2.5 years (range = 30 months to 38 years and median weight of 10 Kg (range 4.5-80.5 Kg underwent percutaneous closure of PDA using the ADO. The devices were implanted under fluoroscopic guidance. Patients were followed-up for any complications. Results: The mean diameter of narrow part of PDA was 6.4 ± 2.2 mm. The mean diameter of devices was 7.8 ± 2.3 mm. The devices were successfully implanted in 239 (98.3% cases. At immediate, 1 day, 1, 6, 12 months and late follow-up, the complete occlusion rate was 33% (79 case, 97.1% (236 case, 97.5% (237 case, 98.3% (238 case, 98.3% (238 case and 98.3% (238 case, respectively. Residual shunt remained in one case at late follow-up. The device embolisation occurred in five patients. The devices were successful retrieved in three patient and second larger devices were inserted. Two other devices were surgically retrieved and PDAs were ligated. Moderate left pulmonary artery stenosis (LPA in one child and mild LPA stenosis in one infant were detected. Mild aortic obstruction occurred in one infant. Conclusions: Long-term follow-up of patients indicate that percutaneous closure of PDA using ADO is a safe and effective procedure. However, some complications, including device embolisation, left pulmonary stenosis and aortic obstruction may be observed in some cases.

  6. On Conservation Equation Combinations and Closure Relations

    Directory of Open Access Journals (Sweden)

    William G. Gray

    2014-07-01

    Full Text Available Fundamental conservation equations for mass, momentum and energy of chemical species can be combined with thermodynamic relations to obtain secondary forms, such as conservation equations for phases, an internal energy balance and a mechanical energy balance. In fact, the forms of secondary equations are infinite and depend on the criteria used in determining which species-based equations to employ and how to combine them. If one uses these secondary forms in developing an entropy inequality to be used in formulating closure relations, care must be employed to ensure that the appropriate equations are used, or problematic results can develop for multispecies systems. We show here that the use of the fundamental forms minimizes the chance of an erroneous formulation in terms of secondary forms and also provides guidance as to which secondary forms should be used if one uses them as a starting point.

  7. Occupational closure in nursing work reconsidered

    DEFF Research Database (Denmark)

    Traynor, Michael; Nissen, Nina; Lincoln, Carol

    2015-01-01

    In healthcare, occupational groups have adopted tactics to maintain autonomy and control over their areas of work. Witz described a credentialist approach to occupational closure adopted by nursing in the United Kingdom during the 19th and early 20th centuries. However, the recent advancement...... = 59). The aim was to examine how these workers positioned themselves as professionals and accounted for professional boundaries. A thematic analysis revealed a complex situation in which participants were divided between articulating an acceptance of a subordinate role within traditional occupational......, while nurses abandon it for largely administrative roles. We conclude that the participants are the not unwilling agents of a managerially led project to reshape the workforce that cuts across existing occupational boundaries....

  8. Asymptotic Behavior of Integral Closures in Modules

    Institute of Scientific and Technical Information of China (English)

    R.Naghipour; P.Schenzel

    2007-01-01

    Let R be a commutative Noetherian Nagata ring,let M be a non-zero finitely generated R-module,and let I be an ideal of R such that height M I > O.In this paper,there is a definition of the integral closure Na for any submodule N of M extending Rees'definition for the case of a domain.As the main results,it is shown that the operation N →Na on the set of submodules N of M is a semi-prime operation,and for any submodule Nof M,the sequences Ass R M/(InN)a and hssR(InM)a/(InN)a (n=1,2,...) of associated prime ideals are increasing and ultimately constant for large n.

  9. Notice of car park and road closures

    CERN Multimedia

    2006-01-01

    The transfer of the two HF CMS detectors between Hall 186 and Point 5 (a convoy measuring 64 metres in length and weighing 440 tonnes) will result in the temporary closure of the following car parks: Building186: south entrance Building 613 Building 28 Building181 south entrance Building 600 Building 31 Route OPPENHEIMER The car parks concerned will be closed from Sunday 2 July until the evening of Tuesday 4 July and from Sunday 9 July until the evening of Tuesday 11 July 2006. Route FEYNMAN is also expected to be closed to traffic from mid-morning on Monday 3 July until the evening of Tuesday 4 July and from mid-morning on Monday 10 July until the evening of Tuesday 11 July (possible deviation via route FERMI and route RUTHERFORD). Thank you for your cooperation. TS-IC Group Tel. 163380 - 164043

  10. Notice of car park and road closures

    CERN Multimedia

    2006-01-01

    The transfer of the two HF CMS detectors between Hall 186 and Point 5 (a convoy measuring 64 metres in length and weighing 440 tonnes) will result in the temporary closure of the following car parks: Building186: south entrance Building 613 Building 28 Building181 south entrance Building 600 Building 31 Route OPPENHEIMER The car parks concerned will be closed from Sunday 2 July until the evening of Tuesday 4 July and from Sunday 9 July until the evening of Tuesday 11 July 2006.Route FEYNMAN is also expected to be closed to traffic from mid-morning on Monday 3 July until the evening of Tuesday 4 July and from mid-morning on Monday 10 July until the evening of Tuesday 11 July (possible deviation via route FERMI and route RUTHERFORD).Thank you for your cooperation. TS-IC GroupTel. 163380 - 164043

  11. Spontaneous closure of midline diastema following frenectomy

    Directory of Open Access Journals (Sweden)

    Koora Kiran

    2007-03-01

    Full Text Available Maxillary midline diastema is a common aesthetic problem in mixed and early permanent dentitions. The space can occur either as a transient malocclusion or created by developmental, pathological or iatrogenical factors. Many innovative therapies varying from restorative procedures such as composite build-up to surgery (frenectomies and orthodontics are available. Although literature says every frenectomy procedure should be preceded by orthodontic treatment, we opted for frenectomy technique without any orthodontic intervention. Presented herewith is a case report of a 9-year-old girl with a high frenal attachment that had caused spacing of the maxillary central incisors. A spontaneous closure of the midline diastema was noted within 2 months following frenectomy. The patient was followed up for 4 months after which the space remained closed and there was no necessity for an orthodontic treatment at a later stage.

  12. Spontaneous closure of midline diastema following frenectomy.

    Science.gov (United States)

    Koora, Kiran; Muthu, M S; Rathna, Prabhu V

    2007-03-01

    Maxillary midline diastema is a common aesthetic problem in mixed and early permanent dentitions. The space can occur either as a transient malocclusion or created by developmental, pathological or iatrogenical factors. Many innovative therapies varying from restorative procedures such as composite build-up to surgery (frenectomies) and orthodontics are available. Although literature says every frenectomy procedure should be preceded by orthodontic treatment, we opted for frenectomy technique without any orthodontic intervention. Presented herewith is a case report of a 9-year-old girl with a high frenal attachment that had caused spacing of the maxillary central incisors. A spontaneous closure of the midline diastema was noted within 2 months following frenectomy. The patient was followed up for 4 months after which the space remained closed and there was no necessity for an orthodontic treatment at a later stage.

  13. Dynamics of electrochemical flows 3 Closure models

    CERN Document Server

    Xu, Chengjun

    2013-01-01

    The electrolyte (comprising of solute ions and solvents) flow-through the porous media is frequently encountered in nature or in many engineering applications, such as the electrochemical systems, manufacturing of composites, oil production, geothermal engineering, nuclear thermal disposal, soil pollution. Our previous work derived the interfacial interaction terms between the solid and the fluid, which can be used to investigate the details of transports of mass, heat, electric flied, potential, or momentum in the process of the electrochemical flows-through porous electrode. In this work, we establish the closure models for these interfacial interaction terms to close the governing equations from mathematical algebra. The interfacial interaction terms regard to the electric field, potential and electric force are firstly revealed. Our new theory provides a new approach to describe the electrochemical flows-through porous media.

  14. ICPP tank farm closure study. Volume 1

    Energy Technology Data Exchange (ETDEWEB)

    Spaulding, B.C.; Gavalya, R.A.; Dahlmeir, M.M. [and others

    1998-02-01

    The disposition of INEEL radioactive wastes is now under a Settlement Agreement between the DOE and the State of Idaho. The Settlement Agreement requires that existing liquid sodium bearing waste (SBW), and other liquid waste inventories be treated by December 31, 2012. This agreement also requires that all HLW, including calcined waste, be disposed or made road ready to ship from the INEEL by 2035. Sodium bearing waste (SBW) is produced from decontamination operations and HLW from reprocessing of SNF. SBW and HLW are radioactive and hazardous mixed waste; the radioactive constituents are regulated by DOE and the hazardous constituents are regulated by the Resource Conservation and Recovery Act (RCRA). Calcined waste, a dry granular material, is produced in the New Waste Calcining Facility (NWCF). Two primary waste tank storage locations exist at the ICPP: Tank Farm Facility (TFF) and the Calcined Solids Storage Facility (CSSF). The TFF has the following underground storage tanks: four 18,400-gallon tanks (WM 100-102, WL 101); four 30,000-gallon tanks (WM 103-106); and eleven 300,000+ gallon tanks. This includes nine 300,000-gallon tanks (WM 182-190) and two 318,000 gallon tanks (WM 180-181). This study analyzes the closure and subsequent use of the eleven 300,000+ gallon tanks. The 18,400 and 30,000-gallon tanks were not included in the work scope and will be closed as a separate activity. This study was conducted to support the HLW Environmental Impact Statement (EIS) waste separations options and addresses closure of the 300,000-gallon liquid waste storage tanks and subsequent tank void uses. A figure provides a diagram estimating how the TFF could be used as part of the separations options. Other possible TFF uses are also discussed in this study.

  15. Ferroelectric devices

    CERN Document Server

    Uchino, Kenji

    2009-01-01

    Updating its bestselling predecessor, Ferroelectric Devices, Second Edition assesses the last decade of developments-and setbacks-in the commercialization of ferroelectricity. Field pioneer and esteemed author Uchino provides insight into why this relatively nascent and interdisciplinary process has failed so far without a systematic accumulation of fundamental knowledge regarding materials and device development.Filling the informational void, this collection of information reviews state-of-the-art research and development trends reflecting nano and optical technologies, environmental regulat

  16. Lip interactions and closure duration in labial consonants

    Science.gov (United States)

    Lofqvist, Anders

    2003-04-01

    This study examines interactions between the upper and lower lips in labial consonants where the duration of the oral closure is varied for linguistic purposes. Earlier work has shown that such interactions occur and that their magnitude is partly related to the duration of the oral closure. Lip movements were recorded in native Japanese speakers using a magnetometer system. Results show a positive correlation between the vertical positions of the upper and lower, when both are measured at the point in time where the lower lip reached its peak position during the oral closure. Since the peak vertical position of the lower lip increased with closure duration, the upper lip also had a higher vertical position at the same point in time for long than for short consonants. During the oral closure, the lower lip continued to move upward with a larger movement for long than for short consonants. Due to the mechanical interaction between the lips, the upper lip reversed its downward movement at the onset of the oral closure and also moved upward during the closure, again with a larger movement for long than for short consonants. [Work supported by NIH.

  17. Hemostasis of Left Atrial Appendage Bleed With Lariat Device

    Directory of Open Access Journals (Sweden)

    Amena Hussain, MD

    2014-09-01

    Full Text Available New devices designed for minimally invasive closure of the left atrial appendage (LAA may be a viable alternative for patients in whom anticoagulation is considered high risk. The Lariat (Sentreheart, Redwood City, CA, which is currently FDA-approved for percutaneous closure of tissue, requires both trans-septal puncture and epicardial access. However it requires no anticoagulation after the procedure. Here we describe a case of effusion and tamponade during a Lariat procedure with successful completion of the case and resolution of the effusion.

  18. PRECL: A new method for interferometry imaging from closure phase

    CERN Document Server

    Ikeda, Shiro; Akiyama, Kazunori; Hada, Kazuhiro; Honma, Mareki

    2016-01-01

    For short-wavelength VLBI observations, it is difficult to measure the phase of the visibility function accurately. The closure phases are reliable measurements under this situation, though it is not sufficient to retrieve all of the phase information. We propose a new method, Phase Retrieval from Closure Phase (PRECL). PRECL estimates all the visibility phases only from the closure phases. Combining PRECL with a sparse modeling method we have already proposed, imaging process of VLBI does not rely on dirty image nor self-calibration. The proposed method is tested numerically and the results are promising.

  19. Use of bipedicular advancement flaps for intrauterine closure of myeloschisis.

    Science.gov (United States)

    Mangels, K J; Tulipan, N; Bruner, J P; Nickolaus, D

    2000-01-01

    Several groups have begun to explore the feasibility and utility of intrauterine closure of myelomeningocele. A subset of these fetuses have defects which fall into the category of myeloschisis, and therefore have inadequate skin to enable primary closure. After considerable discussion, it was decided to utilize bipedicular flaps to close these lesions. The procedure is described, and representative examples are shown. To date, 13 of 56 fetuses have required this approach for closure in utero. While this technique generally provides adequate coverage of the dural sac, the cosmetic results have been less than optimal.

  20. Spurious Shell Closures in the Relativistic Mean Field Model

    CERN Document Server

    Geng, L S; Toki, H; Long, W H; Shen, G

    2006-01-01

    Following a systematic theoretical study of the ground-state properties of over 7000 nuclei from the proton drip line to the neutron drip line in the relativistic mean field model [Prog. Theor. Phys. 113 (2005) 785], which is in fair agreement with existing experimental data, we observe a few spurious shell closures, i.e. proton shell closures at Z=58 and Z=92. These spurious shell closures are found to persist in all the effective forces of the relativistic mean field model, e.g. TMA, NL3, PKDD and DD-ME2.

  1. Comparison of Outcomes between Early Fascial Closure and Delayed Abdominal Closure in Patients with Open Abdomen: A Systematic Review and Meta-Analysis

    Directory of Open Access Journals (Sweden)

    Yu Chen

    2014-01-01

    Full Text Available Up to the present, the optimal time to close an open abdomen remains controversial. This study was designed to evaluate whether early fascial abdominal closure had advantages over delayed approach for open abdomen populations. Medline, Embase, and Cochrane Library were searched until April 2013. Search terms included “open abdomen,” “abdominal compartment syndrome,” “laparostomy,” “celiotomy,” “abdominal closure,” “primary,” “delayed,” “permanent,” “fascial closure,” and “definitive closure.” Open abdomen was defined as “fail to close abdominal fascia after a laparotomy.” Mortality, complications, and length of stay were compared between early and delayed fascial closure. In total, 3125 patients were included for final analysis, and 1942 (62% patients successfully achieved early fascial closure. Vacuum assisted fascial closure had no impact on pooled fascial closure rate. Compared with delayed abdominal closure, early fascial closure significantly reduced mortality (12.3% versus 24.8%, RR, 0.53, P<0.0001 and complication incidence (RR, 0.68, P<0.0001. The mean interval from open abdomen to definitive closure ranged from 2.2 to 14.6 days in early fascial closure groups, but from 32.5 to 300 days in delayed closure groups. This study confirmed clinical advantages of early fascial closure over delayed approach in treatment of patients with open abdomen.

  2. Percutaneous left atrial appendage closure: procedural techniques and outcomes.

    Science.gov (United States)

    Saw, Jacqueline; Lempereur, Mathieu

    2014-11-01

    Percutaneous left atrial appendage closure technology for stroke prevention in patients with atrial fibrillation has significantly advanced in the past 2 decades. Several devices are under clinical investigation, and a few have already received Conformité Européene (CE)-mark approval and are available in many countries. The WATCHMAN device (Boston Scientific, Natick, Massachusetts) has the most supportive data and is under evaluation by the U.S. Food and Drug Administration for warfarin-eligible patients. The Amplatzer Cardiac Plug (St. Jude Medical, Plymouth, Minnesota) has a large real-world experience over the past 5 years, and a randomized trial comparing Amplatzer Cardiac Plug with the WATCHMAN device is anticipated in the near future. The Lariat procedure (SentreHEART Inc., Redwood City, California) has also gained interest lately, but early studies were concerning for high rates of serious pericardial effusion and major bleeding. The current real-world experience predominantly involves patients who are not long-term anticoagulation candidates or who are perceived to have high bleeding risks. This pattern of practice is expected to change when the U.S. Food and Drug Administration approves the WATCHMAN device for warfarin-eligible patients. This paper reviews in depth the procedural techniques, safety, and outcomes of the current leading devices. Copyright © 2014 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  3. Left Atrial Appendage Closure Guided by 3D Printed Cardiac Reconstruction: Emerging Directions and Future Trends.

    Science.gov (United States)

    Pellegrino, Pier Luigi; Fassini, Gaetano; DI Biase, Matteo; Tondo, Claudio

    2016-06-01

    Percutaneous left atrial appendage (LAA) occlusion has emerged as an alternative therapeutic approach to medical therapy for stroke prevention in patients with atrial fibrillation. 3D printing is a novel technology able to create a patient specific model of any given anatomical portion of the heart. Herein we report the first 2 cases of LAA occlusion procedure with 2 different systems, the Wave Crest device (Coherex Medical, Inc., USA) and the Amplatzer Amulet device (St. Jude Medical, St. Paul, MN, USA), in which a 3D printed LAA model (Care Tronik, Prato, Italy) was used in a rehearse phase. Both patients had history of paroxysmal AF and previous transient ischemic attack (TIA) occurred during oral anticoagulation with correct INR. In the first patient the occlusive device was positioned within the LAA after a rehearse occlusion using the 3D printed LAA plus a 27 mm Coherex Wavecrest device, demonstrating a good compression and sealing, particularly considering a proximal lobe of the appendage. In the second patient an attempt with the 27 mm Amulet device delivered within the 3D printed LAA, based on angiography and transesophageal echocardiographic (TEE), revealed insufficient covering of the proximal part of LAA vestibule; the device was released only after a second test with the 31 mm Amulet demonstrating a good sealing. These 2 cases demonstrated that 3D model could help in finding the correct position within LAA, sizing the device and guiding the choice of the closure device despite the measurements provided by angiography and TEE. © 2016 Wiley Periodicals, Inc.

  4. Case Report: Rapid staged abdominal closure using Gore-Tex® mesh as a bridge to primary omphalocele sac closure

    Directory of Open Access Journals (Sweden)

    William C. Kethman

    2016-06-01

    Full Text Available Omphaloceles present an ongoing challenge due to significant variations in presentation and associated co-morbidities. Diverse management strategies have been described to tackle many of the fundamental challenges of closure and reconstruction of the abdominal wall – this fact demonstrates a need for increasingly individualized management options for this complex disease. We describe a novel method of rapid staged abdominal wall closure using Gore-Tex® mesh as a bridge to primary omphalocele closure in an infant with partial Pentalogy of Cantrell and giant ruptured omphalocele. This strategy can be used in management of some of the most complex abdominal wall defects.

  5. Don’t call it a closure!

    CERN Multimedia

    Rosaria Marraffino

    2015-01-01

    During the Laboratory’s annual closure, some members of the personnel joined their families, others seized the chance to travel the world. The Restaurants were closed, the corridors were dark and the heating was turned off in most of the buildings. However, a lot of people spent the Christmas break working on site and the Bulletin would like to dedicate this first article of the new year to them all!   In the CERN Control Centre (CCC), each shift had two people in position to guarantee regular 24/7 service and to intervene in case of need. Gildas Langlois and Rodolphe Maillet, CCC operators from the Beams Department, spent Christmas Eve there and celebrated it with a cake. “I volunteered to work during the holidays in order to allow colleagues to stay with their families,” says Maillet. On New Year’s Eve, it was Julien Pache and Jean-Michel Nonglaton’s turn to spend the night at work. They had a nice dinner with a CCC-made fondue and some desse...

  6. Friction or Closure: Heritage as Loss

    Directory of Open Access Journals (Sweden)

    Mikela Lundahl

    2014-12-01

    Full Text Available Heritage is a discourse that aims at closure. It fixates the narrative of the past through the celebration of specific material (or sometimes immaterial non- objects. It organizes temporality and construct events and freezes time. How does this unfold in the case of the UNESCO World Heritage site of Stone Town, Zanzibar? It is a place of beauty and violence, of trade, slavery and tourism, and the World Heritage narrative does not accommodate all its significant historical facts and lived memories. In this article I will discuss some of these conflicting or competing historical facts. The anthropologist Anna Tsing has developed the concept-metaphor friction as a way to discuss the energy created when various actors narrate 'the same' event(s in different ways, and see the other participants' accounts as fantasies or even fabrications. I will use my position as researcher and my relations to different sources: informants, authorities and texts, and discuss how different accounts relate to and partly construct each other; and how I, in my own process as an analyst and listener, negotiate these conflicting stories, what I identify as valid and non valid accounts. The case in this article is Stone Town in Zanzibar and the development and dissolution going on under the shadow of the UNESCO World Heritage flag; a growing tourism; a global and local increase in islamisation; and the political tension within the Tanzanian union. My main focus is narratives of the identity of Zanzibar since heritagization constructs identity.

  7. Ventricular assist device

    Science.gov (United States)

    VAD; RVAD; LVAD; BVAD; Right ventricular assist device; Left ventricular assist device; Biventricular assist device; Heart pump; Left ventricular assist system; LVAS; Implantable ventricular assist device

  8. Maximum-entropy closure of hydrodynamic moment hierarchies including correlations.

    Science.gov (United States)

    Hughes, Keith H; Burghardt, Irene

    2012-06-07

    Generalized hydrodynamic moment hierarchies are derived which explicitly include nonequilibrium two-particle and higher-order correlations. The approach is adapted to strongly correlated media and nonequilibrium processes on short time scales which necessitate an explicit treatment of time-evolving correlations. Closure conditions for the extended moment hierarchies are formulated by a maximum-entropy approach, generalizing related closure procedures for kinetic equations. A self-consistent set of nonperturbative dynamical equations are thus obtained for a chosen set of single-particle and two-particle (and possibly higher-order) moments. Analytical results are derived for generalized Gaussian closures including the dynamic pair distribution function and a two-particle correction to the current density. The maximum-entropy closure conditions are found to involve the Kirkwood superposition approximation.

  9. Autocracy bias in informal groups under need for closure.

    Science.gov (United States)

    Pierro, Antonio; Mannetti, Lucia; De Grada, Eraldo; Livi, Stefano; Kruglanski, Arie W

    2003-03-01

    Two experiments investigated the tendency of groups with members under high (vs. low) need for cognitive closure to develop an autocratic leadership structure in which some members dominate the discussion, constitute the "hubs" of communication, and influence the group more than other members. The first experiment found that high (vs. low) need for closure groups, as assessed via dispositional measure of the need for closure, manifested greater asymmetry of conversational floor control, such that members with autocratic interactional style were more conversationally dominant and influential than less autocratic members. The second experiment manipulated the need for closure via time pressure and utilized a social network analysis. Consistent with expectation, groups under time pressure (vs. no pressure) showed a greater asymmetry of participation, of centrality, and of prestige among the group members, such that the more focal members were perceived to exert the greater influence over the groups' decisions.

  10. Simultaneous oroantral communication closure, sinus‑lifting, and ...

    African Journals Online (AJOL)

    2015-10-10

    Oct 10, 2015 ... revealed healthy and functional implants in the teeth area. Key words: .... the development of several alternative treatment modalities by some ... 1. Lee BK. One‑stage operation of large oroantral fistula closure, sinus lifting,.

  11. Optical closure of parameterized bio-optical relationships

    Science.gov (United States)

    He, Shuangyan; Fischer, Jürgen; Schaale, Michael; He, Ming-xia

    2014-03-01

    An optical closure study on bio-optical relationships was carried out using radiative transfer model matrix operator method developed by Freie Universität Berlin. As a case study, the optical closure of bio-optical relationships empirically parameterized with in situ data for the East China Sea was examined. Remote-sensing reflectance ( R rs) was computed from the inherent optical properties predicted by these biooptical relationships and compared with published in situ data. It was found that the simulated R rs was overestimated for turbid water. To achieve optical closure, bio-optical relationships for absorption and scattering coefficients for suspended particulate matter were adjusted. Furthermore, the results show that the Fournier and Forand phase functions obtained from the adjusted relationships perform better than the Petzold phase function. Therefore, before bio-optical relationships are used for a local sea area, the optical closure should be examined.

  12. 40 CFR 264.119 - Post-closure notices.

    Science.gov (United States)

    2010-07-01

    ... disposal unit is located wishes to remove hazardous wastes and hazardous waste residues, the liner, if any, or contaminated soils, he must request a modification to the post-closure permit in accordance...

  13. 300 Area waste acid treatment system closure plan

    Energy Technology Data Exchange (ETDEWEB)

    LUKE, S.N.

    1999-05-17

    The Hanford Facility Dangerous Waste Permit Application is considered to be a single application organized into a General Information Portion (document number DOERL-91-28) and a Unit-Specific Portion. The scope of the Unit-Specific Portion includes closure plan documentation submitted for individual, treatment, storage, and/or disposal units undergoing closure, such as the 300 Area Waste Acid Treatment System. Documentation contained in the General Information Portion is broader in nature and could be used by multiple treatment, storage, and/or disposal units (e.g., the glossary provided in the General Information Portion). Whenever appropriate, 300 Area Waste Acid Treatment System documentation makes cross-reference to the General Information Portion, rather than duplicating text. This 300 Area Waste Acid Treatment System Closure Plan (Revision 2) includes a Hanford Facility Dangerous Waste Permit Application, Part A, Form 3. Information provided in this closure plan is current as of April 1999.

  14. EPIDERMAL DELETION OF HIF-2α STIMULATES WOUND CLOSURE

    Science.gov (United States)

    Cowburn, Andrew S.; Crotty Alexander, Laura E.; Southwood, Mark; Nizet, Victor; Chilvers, Edwin R.; Johnson, Randall S.

    2013-01-01

    Wound closure requires a complex series of micro-environmentally influenced events. A key aspect of wound closure is the migration of keratinocytes across the open wound. It has been found previously that the response to hypoxia via the HIF-1α transcription factor is a key feature of wound closure. The need for hypoxic response is likely due to interrupted wound vasculature as well as infection, and in this work, we investigated the need for a highly related hypoxic response transcription factor, HIF-2α. This factor was deleted tissue-specifically in mice, and the resulting mice were found to have an accelerated rate of wound closure. This is correlated with a reduced bacterial load and inflammatory response in these mice. This indicates that manipulating or reducing the HIF-2α response in keratinocytes could be a useful means to accelerate wound healing and tissue repair. PMID:24037341

  15. Procedures adopted by orthodontists for space closure and anchorage control

    Directory of Open Access Journals (Sweden)

    André da Costa Monini

    2013-12-01

    Full Text Available OBJECTIVE: The aim of this study was to identify the procedures adopted by Brazilian orthodontists in the following situations: extraction space closure, anchorage control in case of necessary anchorage for group A and frequency of skeletal anchorage use, especially in the upper jaw. METHOD: A questionnaire was sent to the e-mail address of all dentists registered in the Brazilian Federal Council of Dentistry. RESULTS: The results showed that most Brazilian orthodontists usually perform extraction space closure by means of sliding mechanics. The use of palatal bar, inclusion of second molars in the archwire and space closure performed in two phases are the most used techniques for anchorage control in the upper jaw. The skeletal anchorage is referenced by 36.5% of specialists as a routine practice for the upper jaw anchorage. CONCLUSIONS: There is a wide variety of procedures adopted by Brazilian orthodontists for orthodontic space closure and anchorage control.

  16. Nonlinear closures for scale separation in supersonic magnetohydrodynamic turbulence

    CERN Document Server

    Grete, Philipp; Schmidt, Wolfram; Schleicher, Dominik R G; Federrath, Christoph

    2015-01-01

    Turbulence in compressible plasma plays a key role in many areas of astrophysics and engineering. The extreme plasma parameters in these environments, e.g. high Reynolds numbers, supersonic and super-Alfvenic flows, however, make direct numerical simulations computationally intractable even for the simplest treatment -- magnetohydrodynamics (MHD). To overcome this problem one can use subgrid-scale (SGS) closures -- models for the influence of unresolved, subgrid-scales on the resolved ones. In this work we propose and validate a set of constant coefficient closures for the resolved, compressible, ideal MHD equations. The subgrid-scale energies are modeled by Smagorinsky-like equilibrium closures. The turbulent stresses and the electromotive force (EMF) are described by expressions that are nonlinear in terms of large scale velocity and magnetic field gradients. To verify the closures we conduct a priori tests over 137 simulation snapshots from two different codes with varying ratios of thermal to magnetic pre...

  17. Neural tube closure: cellular, molecular and biomechanical mechanisms.

    Science.gov (United States)

    Nikolopoulou, Evanthia; Galea, Gabriel L; Rolo, Ana; Greene, Nicholas D E; Copp, Andrew J

    2017-02-15

    Neural tube closure has been studied for many decades, across a range of vertebrates, as a paradigm of embryonic morphogenesis. Neurulation is of particular interest in view of the severe congenital malformations - 'neural tube defects' - that result when closure fails. The process of neural tube closure is complex and involves cellular events such as convergent extension, apical constriction and interkinetic nuclear migration, as well as precise molecular control via the non-canonical Wnt/planar cell polarity pathway, Shh/BMP signalling, and the transcription factors Grhl2/3, Pax3, Cdx2 and Zic2. More recently, biomechanical inputs into neural tube morphogenesis have also been identified. Here, we review these cellular, molecular and biomechanical mechanisms involved in neural tube closure, based on studies of various vertebrate species, focusing on the most recent advances in the field.

  18. Approximate maximum-entropy moment closures for gas dynamics

    Science.gov (United States)

    McDonald, James G.

    2016-11-01

    Accurate prediction of flows that exist between the traditional continuum regime and the free-molecular regime have proven difficult to obtain. Current methods are either inaccurate in this regime or prohibitively expensive for practical problems. Moment closures have long held the promise of providing new, affordable, accurate methods in this regime. The maximum-entropy hierarchy of closures seems to offer particularly attractive physical and mathematical properties. Unfortunately, several difficulties render the practical implementation of maximum-entropy closures very difficult. This work examines the use of simple approximations to these maximum-entropy closures and shows that physical accuracy that is vastly improved over continuum methods can be obtained without a significant increase in computational cost. Initially the technique is demonstrated for a simple one-dimensional gas. It is then extended to the full three-dimensional setting. The resulting moment equations are used for the numerical solution of shock-wave profiles with promising results.

  19. Patent Foramen Ovale Closure or Antiplatelet Therapy for Cryptogenic Stroke

    DEFF Research Database (Denmark)

    Søndergaard, Lars; Kasner, Scott E; Rhodes, John F

    2017-01-01

    Background The efficacy of closure of a patent foramen ovale (PFO) in the prevention of recurrent stroke after cryptogenic stroke is uncertain. We investigated the effect of PFO closure combined with antiplatelet therapy versus antiplatelet therapy alone on the risks of recurrent stroke and new...... brain infarctions. Methods In this multinational trial involving patients with a PFO who had had a cryptogenic stroke, we randomly assigned patients, in a 2:1 ratio, to undergo PFO closure plus antiplatelet therapy (PFO closure group) or to receive antiplatelet therapy alone (antiplatelet-only group......). Imaging of the brain was performed at the baseline screening and at 24 months. The coprimary end points were freedom from clinical evidence of ischemic stroke (reported here as the percentage of patients who had a recurrence of stroke) through at least 24 months after randomization and the 24-month...

  20. Threats and opportunities for post-closure development in dolomitic ...

    African Journals Online (AJOL)

    Threats and opportunities for post-closure development in dolomitic ... in the form of sinkholes and widespread radioactive pollution exacerbate such fears. ... developments such as aquaculture, agriculture and different forms of tourism relating ...

  1. 300 Area waste acid treatment system closure plan. Revision 1

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-03-01

    This section provides a description of the Hanford Site, identifies the proposed method of 300 Area Waste Acid Treatment System (WATS) closure, and briefly summarizes the contents of each chapter of this plan.

  2. Economic evaluation of closure cap barrier materials study

    Energy Technology Data Exchange (ETDEWEB)

    Serrato, M.G.; Bhutani, J.S.; Mead, S.M.

    1993-09-01

    Volume II of the Economic Evaluation of the Closure Cap Barrier Materials, Revision I contains detailed cost estimates for closure cap barrier materials. The cost estimates incorporate the life cycle costs for a generic hazardous waste seepage basin closure cap under the RCRA Post Closure Period of thirty years. The economic evaluation assessed six barrier material categories. Each of these categories consists of several composite cover system configurations, which were used to develop individual cost estimates. The information contained in this report is not intended to be used as a cost estimating manual. This information provides the decision makers with the ability to screen barrier materials, cover system configurations, and identify cost-effective materials for further consideration.

  3. A closure relation to molecular theory of solvation for macromolecules

    Science.gov (United States)

    Kobryn, Alexander E.; Gusarov, Sergey; Kovalenko, Andriy

    2016-10-01

    We propose a closure to the integral equations of molecular theory of solvation, particularly suitable for polar and charged macromolecules in electrolyte solution. This includes such systems as oligomeric polyelectrolytes at a finite concentration in aqueous and various non-aqueous solutions, as well as drug-like compounds in solution. The new closure by Kobryn, Gusarov, and Kovalenko (KGK closure) imposes the mean spherical approximation (MSA) almost everywhere in the solvation shell but levels out the density distribution function to zero (with the continuity at joint boundaries) inside the repulsive core and in the spatial regions of strong density depletion emerging due to molecular associative interactions. Similarly to MSA, the KGK closure reduces the problem to a linear equation for the direct correlation function which is predefined analytically on most of the solvation shells and has to be determined numerically on a relatively small (three-dimensional) domain of strong depletion, typically within the repulsive core. The KGK closure leads to the solvation free energy in the form of the Gaussian fluctuation (GF) functional. We first test the performance of the KGK closure coupled to the reference interaction site model (RISM) integral equations on the examples of Lennard-Jones liquids, polar and nonpolar molecular solvents, including water, and aqueous solutions of simple ions. The solvation structure, solvation chemical potential, and compressibility obtained from RISM with the KGK closure favorably compare to the results of the hypernetted chain (HNC) and Kovalenko-Hirata (KH) closures, including their combination with the GF solvation free energy. We then use the KGK closure coupled to RISM to obtain the solvation structure and thermodynamics of oligomeric polyelectrolytes and drug-like compounds at a finite concentration in electrolyte solution, for which no convergence is obtained with other closures. For comparison, we calculate their solvation

  4. The StarClose Vascular Closure System: interventional results from the CLIP study.

    Science.gov (United States)

    Hermiller, J B; Simonton, C; Hinohara, T; Lee, D; Cannon, L; Mooney, M; O'Shaughnessy, C; Carlson, H; Fortuna, R; Zapien, M; Fletcher, D R; DiDonato, K; Chou, T M

    2006-11-01

    The StarClose Vascular Closure System is a femoral access site closure technology that uses a flexible nitinol clip to complete a circumferential, extravascular arteriotomy close. The Clip CLosure In Percutaneous Procedures study was initiated to study the safety and efficacy of the StarClose device in subjects undergoing diagnostic and interventional catheterization procedures. A total of 17 U.S. sites enrolled 596 subjects, with 483 subjects randomized at a 2:1 ratio to receive StarClose or standard compression of the arteriotomy after the percutaneous procedure. The study included roll-in (n = 113), diagnostic (n = 208), and interventional (n = 275) arms with a primary safety endpoint of major vascular complications through 30 days and a primary efficacy endpoint of postprocedure time to hemostasis. The results of the diagnostic StarClose cohort have been reported separately. Results for the interventional arm revealed major vascular complications occurring in 1.1% of StarClose subjects (2/184) and 1.1% in manual compression subjects (1/91; P = 1.00). No infections were seen in either cohort. Minor complications in the StarClose interventional group occurred at a rate of 4.3% (8/184) and with compression at 9.9% (9/91; P = 0.107). Pseudoaneurysm or arteriovenous fistula was not seen with StarClose. With StarClose, procedural success was 100% (136/136) for the diagnostic group and 98.9% (181/183) in the interventional group. Device success for the treatment group was 86.8%. In the interventional cohort, 87.3% (158/181) of StarClose subjects reported a pain scale of 0-3 compared with 93.3% (84/90) in the compression group, which was not statistically different. The clinical results of this study demonstrate that the StarClose Vascular Closure System is noninferior to manual compression with respect to the primary safety endpoint of major vascular events in subjects who undergo percutaneous interventional procedures. StarClose significantly reduced time to

  5. 303-K Storage Facility report on FY98 closure activities

    Energy Technology Data Exchange (ETDEWEB)

    Adler, J.G.

    1998-07-17

    This report summarizes and evaluates the decontamination activities, sampling activities, and sample analysis performed in support of the closure of the 303-K Storage Facility. The evaluation is based on the validated data included in the data validation package (98-EAP-346) for the 303-K Storage Facility. The results of this evaluation will be used for assessing contamination for the purpose of closing the 303-K Storage Facility as described in the 303-K Storage Facility Closure Plan, DOE/RL-90-04. The closure strategy for the 303-K Storage Facility is to decontaminate the interior of the north half of the 303-K Building to remove known or suspected dangerous waste contamination, to sample the interior concrete and exterior soils for the constituents of concern, and then to perform data analysis, with an evaluation to determine if the closure activities and data meet the closure criteria. The closure criteria for the 303-K Storage Facility is that the concentrations of constituents of concern are not present above the cleanup levels. Based on the evaluation of the decontamination activities, sampling activities, and sample data, determination has been made that the soils at the 303-K Storage Facility meet the cleanup performance standards (WMH 1997) and can be clean closed. The evaluation determined that the 303-K Building cannot be clean closed without additional closure activities. An additional evaluation will be needed to determine the specific activities required to clean close the 303-K Storage Facility. The radiological contamination at the 303-K Storage Facility is not addressed by the closure strategy.

  6. Synthesis of Pyridoacridines through Anionic Cascade Ring Closure

    DEFF Research Database (Denmark)

    Petersen, I.N.; Kristensen, Jesper Langgaard

    2014-01-01

    A new synthesis of 13-deazaascididemin (AK-37) based on a recently developed anionic cascade ring closure is presented. Although the isolated yields are modest, the approach provides ready access to new substituted derivatives of 13-deazaascididemin. © Georg Thieme Verlag.......A new synthesis of 13-deazaascididemin (AK-37) based on a recently developed anionic cascade ring closure is presented. Although the isolated yields are modest, the approach provides ready access to new substituted derivatives of 13-deazaascididemin. © Georg Thieme Verlag....

  7. Techniques and materials for skin closure in caesarean section

    DEFF Research Database (Denmark)

    Mackeen, A Dhanya; Berghella, Vincenzo; Larsen, Mie-Louise

    2012-01-01

    Caesarean section is a common operation with no agreed upon standard regarding certain operative techniques or materials to use. With regard to skin closure, the skin incision can be re-approximated by a subcuticular suture immediately below the skin layer, by an interrupted suture, or by staples....... A great variety of materials and techniques are used for skin closure after caesarean section and there is a need to identify which provide the best outcomes for women....

  8. Apoptosis is not required for mammalian neural tube closure.

    Science.gov (United States)

    Massa, Valentina; Savery, Dawn; Ybot-Gonzalez, Patricia; Ferraro, Elisabetta; Rongvaux, Anthony; Cecconi, Francesco; Flavell, Richard; Greene, Nicholas D E; Copp, Andrew J

    2009-05-19

    Apoptotic cell death occurs in many tissues during embryonic development and appears to be essential for processes including digit formation and cardiac outflow tract remodeling. Studies in the chick suggest a requirement for apoptosis during neurulation, because inhibition of caspase activity was found to prevent neural tube closure. In mice, excessive apoptosis occurs in association with failure of neural tube closure in several genetic mutants, but whether regulated apoptosis is also necessary for neural tube closure in mammals is unknown. Here we investigate the possible role of apoptotic cell death during mouse neural tube closure. We confirm the presence of apoptosis in the neural tube before and during closure, and identify a correlation with 3 main events: bending and fusion of the neural folds, postfusion remodeling of the dorsal neural tube and surface ectoderm, and emigration of neural crest cells. Both Casp3 and Apaf1 null embryos exhibit severely reduced apoptosis, yet neurulation proceeds normally in the forebrain and spine. In contrast, the mutant embryos fail to complete neural tube closure in the midbrain and hindbrain. Application of the apoptosis inhibitors z-Vad-fmk and pifithrin-alpha to neurulation-stage embryos in culture suppresses apoptosis but does not prevent initiation or progression of neural tube closure along the entire neuraxis, including the midbrain and hindbrain. Remodeling of the surface ectoderm to cover the closed tube, as well as delamination and migration of neural crest cells, also appear to be normal in the apoptosis-suppressed embryos. We conclude that apoptosis is not required for neural tube closure in the mouse embryo.

  9. Primary fascial closure with laparoscopic ventral hernia repair: systematic review.

    Science.gov (United States)

    Nguyen, Duyen H; Nguyen, Mylan T; Askenasy, Erik P; Kao, Lillian S; Liang, Mike K

    2014-12-01

    Laparoscopic ventral hernia repair (LVHR) has grown in popularity. Typically, this procedure is performed with a mesh bridge technique that results in high rates of seroma, eventration (bulging), and patient dissatisfaction. In an effort to avoid these complications, there is growing interest in the role of laparoscopic primary fascial closure with intraperitoneal mesh placement. This systematic review evaluated the outcomes of closure of the central defect during LVHR. A literature search of PubMed, Cochrane databases, and Embase was conducted using PRISMA guidelines. MINORS was used to assess the methodologic quality. Primary outcome was hernia recurrence. Secondary outcomes were surgical-site infection, seroma formation, bulging, and patient-centered items (satisfaction, chronic pain, functional status). Eleven studies were identified, eight of which were case series (level 4 data). Three comparative studies examined the difference between closure and nonclosure of the fascial defect during laparoscopic ventral incisional hernia repairs (level 3 and 4 data). These studies suggested that primary fascial closure (n = 138) compared to nonclosure (n = 255) resulted in lower recurrence rates (0-5.7 vs. 4.8-16.7 %) and seroma formation rates (5.6-11.4 vs. 4.3-27.8 %). Follow-up periods for both groups were similar (1-108 months). Only one study evaluated patient function and clinical bulging. It showed better outcomes with primary fascial closure. Closure of the central defect during LVHR resulted in less recurrence, bulging, and seroma than nonclosure. Patients with closure were more satisfied with the results and had better functional status. The quality of the data was poor, however. A randomized controlled trial to evaluate the role of closure of the central defect during LVHR is warranted.

  10. Evaluation of stiffness and plastic deformation of active ceramic self-ligating bracket clips after repetitive opening and closure movements

    Directory of Open Access Journals (Sweden)

    Grace Kelly Martins Carneiro

    2015-08-01

    Full Text Available OBJECTIVE: The aim of this study was to assess whether repetitive opening and closure of self-ligating bracket clips can cause plastic deformation of the clip.METHODS: Three types of active/interactive ceramic self-ligating brackets (n = 20 were tested: In-Ovation C, Quicklear and WOW. A standardized controlled device performed 500 cycles of opening and closure movements of the bracket clip with proper instruments and techniques adapted as recommended by the manufacturer of each bracket type. Two tensile tests, one before and one after the repetitive cycles, were performed to assess the stiffness of the clips. To this end, a custom-made stainless steel 0.40 x 0.40 mm wire was inserted into the bracket slot and adapted to the universal testing machine (EMIC DL2000, after which measurements were recorded. On the loading portion of the loading-unloading curve of clips, the slope fitted a first-degree equation curve to determine the stiffness/deflection rate of the clip.RESULTS: The results of plastic deformation showed no significant difference among bracket types before and after the 500 cycles of opening and closure (p = 0.811. There were significant differences on stiffness among the three types of brackets (p = 0.005. The WOW bracket had higher mean values, whereas Quicklear bracket had lower values, regardless of the opening/closure cycle.CONCLUSION: Repetitive controlled opening and closure movements of the clip did not alter stiffness or cause plastic deformation.

  11. Patent foramen ovale closure following cryptogenic stroke or transient ischaemic attack: Long-term follow-up of 301 cases.

    Science.gov (United States)

    Mirzaali, Mikaeil; Dooley, Maureen; Wynne, Dylan; Cooter, Nina; Lee, Lorraine; Haworth, Peter; Saha, Romi; Gainsborough, Nicola; Hildick-Smith, David

    2015-11-15

    Patent foramen ovale has been identified as a conduit for paradoxical embolism resulting in cryptogenic stroke or transient ischemic attack (TIA). We aimed to establish rates of death, recurrent stroke or TIA among patients undergoing PFO closure for stroke or TIA at our unit. A retrospective analysis of all PFO closure patients was performed between May 2004 and January 2013. Follow up was performed by mortality tracing using the Medical Research Information Service of the Office of National Statistics. With regard to stroke or TIA recurrence, written consent forms and questionnaires were mailed with follow up telephone calls. Medical notes and imaging records were consulted where adverse events were noted. 301 patients aged 48.6 ± 11.0 years, 54.4% male, with ≥1 thromboembolic neurovascular event had percutaneous PFO closure with one of eight devices, with successful implantation in 99% of cases. Follow-up duration was 40.2 ± 26.2 months (range 1.3-105.3); complete in 301 patients for mortality (100%) and 283 patients (94.0%) for neurovascular events. Two patients died during follow-up (respiratory failure n = 1; road traffic accident n = 1). Recurrent stroke (MRI or CT confirmed) was observed in five patients (0.5%; 0.55 per 100 person-years) and TIA in 9 (1.1%; 0.98 per 100 person-years). Atrial fibrillation requiring treatment was documented in 14 patients (1.7%). Percutaneous PFO closure in patients with cryptogenic stroke or TIA is a safe treatment with a low incidence of procedural complications and recurrent neurovascular events. Registry data like these may help to demonstrate the utility of PFO closure in stroke.

  12. Separating device

    NARCIS (Netherlands)

    De Jong, T.P.R.

    2001-01-01

    A sorting device (1) suitable for sorting wire from a waste stream, comprising a body (2) that moves when in use, and provided with spikes or similar projections. The body is embodied as a rotatable roll (2), which oscillates axially during its rotation. The roll is coupled to an oscillation engine

  13. Detection device

    Science.gov (United States)

    Smith, J.E.

    1981-02-27

    The present invention is directed to a detection device comprising: (1) an entrance chamber; (2) a central chamber; and (3) an exit chamber. The central chamber includes an ionizing gas, anode, and means for connecting the anode with an external power supply and pulse counter.

  14. Assistive Devices

    Science.gov (United States)

    ... a number of assistive devices. These are tools, products or types of equipment that help you perform tasks and activities. They may help you move around, see, communicate, eat, or get dressed. Some are high-tech tools, such as computers. Others are much simpler, ...

  15. Printing Device

    NARCIS (Netherlands)

    Berg, van den M.J.; Markies, P.R.; Zuilhof, H.

    2014-01-01

    An ink jetprinting device includes a pressure chamber formed by a plurality of wall segments, a first aperture extending through a wall segment and communicating with an ink jet orifice and a second aperture extending through a wall segment and communicating with an ink supply duct. The pressure

  16. Electrochemical device

    Science.gov (United States)

    Grimes, Patrick G.; Einstein, Harry; Bellows, Richard J.

    1988-01-12

    A tunnel protected electrochemical device features channels fluidically communicating between manifold, tunnels and cells. The channels are designed to provide the most efficient use of auxiliary power. The channels have a greater hydraulic pressure drop and electrical resistance than the manifold. This will provide a design with the optimum auxiliary energy requirements.

  17. Printing Device

    NARCIS (Netherlands)

    Berg, van den M.J.; Markies, P.R.; Zuilhof, H.

    2014-01-01

    An ink jetprinting device includes a pressure chamber formed by a plurality of wall segments, a first aperture extending through a wall segment and communicating with an ink jet orifice and a second aperture extending through a wall segment and communicating with an ink supply duct. The pressure cha

  18. Balancing device

    NARCIS (Netherlands)

    Van Dorsser, W.D.; Herder, J.L.; Wisse B.M.; Barents, R.

    2007-01-01

    The invention relates to a balancing device for a mass, comprising an arm that is adjustable about a pivoting point and with which the mass is coupled, and an adjustable spring system that is coupled with the arm, which spring system comprises at least one spring, wherein the spring system comprises

  19. HERA Mock Observations: Looking for Closure HERA Memorandum Number 13

    CERN Document Server

    Carilli, C L

    2016-01-01

    We investigate the use of closure phase as a method to detect the HI 21cm signal from the neutral IGM during cosmic reionzation. Closure quantities have the unique advantage of being independent of antenna-based calibration terms. We employ realistic, large area sky models from Sims et al. (2016). These include an estimate of the HI 21cm signal generated using 21cm FAST, plus continuum models of both the diffuse Galactic synchrotron emission and the extragalactic point sources. We employ the CASA simulator and adopt the Dillon-Parsons HERA configuration to generate a uv measurement set. We then use AIPS to calculate the closure phases as a function of frequency ('closure spectra'), and python scripts for subsequent analysis. We find that the closure spectra for the HI signal show dramatic structure in frequency, and based on thermal noise alone, the redundant HERA-331 array should detect these fluctuations easily. Comparatively, the frequency structure in the continuum closure spectra is much smoother than th...

  20. OCULAR BIOMETRY IN ANGLE CLOSURE GLAUCOMA AND SENILE CATARACT

    Institute of Scientific and Technical Information of China (English)

    WANG Yu-lan; SHENG Yao-hua; YE Xiang-yu

    2008-01-01

    Objective To compare ocular biometric values in angle closure glaucoma and cataract in senile population.Methods Ocular biometry was performed in eyes classified to have angle closure glaucoma (29 eyes) and senile cataract (31 eyes). Ocular biometry readings between two groups were compared and analyzed statistically. Intraocular pressure was also recorded before and after lens extraction.Results Anterior chamber depth was shallower in patients with angle closure glaucoma group [(1.79±0.56) mm] compared with senile cataract group [(2.69±0.40) mm] (P<0.01). Lens thickness was greater in angle closure glaucoma group [(5.30±0.61) mm] than that in senile cataract group [(3.84±0.61) mm] (P<0.01). Phacoemusification was performed in 5 patients with persistent acute attack of angle closure glaucoma. IOPs were controlled in all five cases after lens extraction.Conclusion Eyes with angle closure glaucoma seems to have significantly shallow anterior chamber and greater lens thickness compared to senile cataract eyes in the same age. Lens extraction might be effective in those cases with such anatomy features.

  1. Levels of control and closure in complex semiotic systems

    Science.gov (United States)

    Joslyn

    2000-01-01

    It is natural to advance closures as atomic processes of universal evolution, and to analyze this concept specifically. Real complex systems like organisms and complex mechanisms cannot exist at either extreme of complete closure or lack of closure, nevertheless we should consider the properties of closures in general, the introduction of boundaries, a corresponding stability, the establishment of system autonomy and identity, and thereby the introduction of emergent new system of potentially new types. Our focus should move from simple physical closure of common objects and classical self-organizing systems to semiotically closed systems that maintain cyclic relations of perception, interpretation, decision, and action with their environments. Thus, issues arise concerning the use and interpretation of symbols, representations, and/or internal models (whether explicit or implicit) by the system; and the syntactic, semantic, and pragmatic relations among the sign tokens, their interpretations, and their use or function for the systems in question. Primitive semiotic closures are hypothesized as equivalent to simple control systems, and in turn equivalent to simple organisms. This leads us directly to the grand hierarchical control theories of Turchin, Powers, and Albus, which provide an explicit mechanism for the formation of new levels within complex semiotically closed systems.

  2. Percutaneous closure versus medical therapy alone for cryptogenic stroke patients with a patent foramen ovale: meta-analysis of randomized controlled trials.

    Science.gov (United States)

    Pickett, Christopher A; Villines, Todd C; Ferguson, Michael A; Hulten, Edward A

    2014-08-01

    Of cryptogenic stroke patients younger than 55 years of age, up to 61% have had a patent foramen ovale (PFO). Observational studies have revealed reductions in recurrent neurologic events through PFO closure versus medical therapy, and randomized controlled trials have shown nonsignificant trends toward benefit. We systematically searched for randomized controlled trials of percutaneous PFO closure with medical therapy versus medical therapy alone in patients with cryptogenic stroke and performed a meta-analysis of treatment outcomes. The primary endpoint was combined death, stroke, and transient ischemic attack. We included 3 trials. Of 2,303 total patients, 1,150 underwent PFO closure and 1,153 received medical therapy (median follow-up period, 2.6 yr). The pooled incidence of the primary endpoint was 1.2 events per 100 patient-years in the closure group (95% confidence interval [CI], 0.2-2.3) and 1.8 in the therapy group (95% CI, 0.7-2.9) (P=0.32); the number needed to treat was 167 (range, 100-500). The corresponding pooled hazard ratio was 0.67 (95% CI, 0.44-1.01; P=0.054) in favor of closure. Closure was associated with an increased risk of atrial fibrillation: relative risk=3.51 (95% CI, 1.44-8.55; P=0.006). When stratified by device, use of the Amplatzer™ PFO Occluder resulted in significant stroke-prevention benefit over medical therapy alone: hazard ratio=0.44 (95% CI, 0.21-0.95; P=0.037). When compared with medical therapy alone, PFO closure with medical therapy showed a trend toward a decreased hazard of combined events, although the absolute event reduction was small and the number needed to treat was high.

  3. The Gore-Tex Suture in Periareolar Closure: A Modified Closure Technique.

    Science.gov (United States)

    Chapman, Jade; Ingram, Scott

    2016-12-01

    In breast reduction and mastopexy procedures, the periareolar closure forms a vital component of the surgery. Periareolar closures completed with an absorbable suture may be prone to significant widening, hypertrophy and/or areolar distortion. In an effort to avoid this, some surgeons use a non-absorbable/permanent suture material [Franco (Arch Plast Surg 41 (6): 728-733, 2014)]. Hammond (Plast Reconstr Surg 119 (3):804-809, 2007) recommends the use of a Gore-Tex® suture for this purpose in view of the supple, pliable nature of the material; however, there remain at least occasional instances of infection and extrusion of the knot used to tie off the Gore-Tex "purse-string" [Franco (Arch Plast Surg 41 (6): 728-733, 2014); Salgarello (Aesthet Plast Surg 37 (5):1061-1062, 2013)]. We describe a method of securing the suture ends, which avoids the creation of a bulky knot, thus minimising the risk of infection and suture extrusion. Level of Evidence V This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .

  4. CLOSURE REPORT FOR CORRECTIVE ACTION UNIT 528: POLYCHLORINATED BIPHENYLS CONTAMINATION NEVADA TEST SITE, NEVADA

    Energy Technology Data Exchange (ETDEWEB)

    BECHTEL NEVADA

    2006-09-01

    This Closure Report (CR) describes the closure activities performed at CAU 528, Polychlorinated Biphenyls Contamination, as presented in the Nevada Division of Environmental Protection (NDEP)-approved Corrective Action Plan (CAP) (US. Department of Energy, National Nuclear Security Administration Nevada Site Office [NNSAINSO], 2005). The approved closure alternative was closure in place with administrative controls. This CR provides a summary of the completed closure activities, documentation of waste disposal, and analytical data to confirm that the remediation goals were met.

  5. CLOSURE REPORT FOR CORRECTIVE ACTION UNIT 528: POLYCHLORINATED BIPHENYLS CONTAMINATION NEVADA TEST SITE, NEVADA

    Energy Technology Data Exchange (ETDEWEB)

    BECHTEL NEVADA

    2006-09-01

    This Closure Report (CR) describes the closure activities performed at CAU 528, Polychlorinated Biphenyls Contamination, as presented in the Nevada Division of Environmental Protection (NDEP)-approved Corrective Action Plan (CAP) (US. Department of Energy, National Nuclear Security Administration Nevada Site Office [NNSAINSO], 2005). The approved closure alternative was closure in place with administrative controls. This CR provides a summary of the completed closure activities, documentation of waste disposal, and analytical data to confirm that the remediation goals were met.

  6. Closure versus non-closure of the peritoneum at caesarean section: short- and long-term outcomes

    OpenAIRE

    Bamigboye, Anthony A; Hofmeyr, G Justus

    2014-01-01

    Background Caesarean section is a very common surgical procedure worldwide. Suturing the peritoneal layers at caesarean section may or may not confer benefit, hence the need to evaluate whether this step should be omitted or routinely performed. Objectives The objective of this review was to assess the effects of non-closure as an alternative to closure of the peritoneum at caesarean section on intraoperative and immediate- and long-term postoperative outcomes. Search methods We searched the ...

  7. 216-B-3 expansion ponds closure plan

    Energy Technology Data Exchange (ETDEWEB)

    1994-10-01

    This document describes the activities for clean closure under the Resource Conservation and Recovery Act of 1976 (RCRA) of the 216-B-3 Expansion Ponds. The 216-B-3 Expansion Ponds are operated by the US Department of Energy, Richland Operations Office (DOE-RL) and co-operated by Westinghouse Hanford Company (Westinghouse Hanford). The 216-B-3 Expansion Ponds consists of a series of three earthen, unlined, interconnected ponds that receive waste water from various 200 East Area operating facilities. The 3A, 3B, and 3C ponds are referred to as Expansion Ponds because they expanded the capability of the B Pond System. Waste water (primarily cooling water, steam condensate, and sanitary water) from various 200 East Area facilities is discharged to the Bypass pipe (Project X-009). Water discharged to the Bypass pipe flows directly into the 216-B-3C Pond. The ponds were operated in a cascade mode, where the Main Pond overflowed into the 3A Pond and the 3A Pond overflowed into the 3C Pond. The 3B Pond has not received waste water since May 1985; however, when in operation, the 3B Pond received overflow from the 3A Pond. In the past, waste water discharges to the Expansion Ponds had the potential to have contained mixed waste (radioactive waste and dangerous waste). The radioactive portion of mixed waste has been interpreted by the US Department of Energy (DOE) to be regulated under the Atomic Energy Act of 1954; the dangerous waste portion of mixed waste is regulated under RCRA.

  8. Microwave Tissue Soldering for Immediate Wound Closure

    Science.gov (United States)

    Arndt, G. Dickey; Ngo, Phong H.; Phan, Chau T.; Byerly, Diane; Dusl, John; Sognier, Marguerite A.; Carl, James

    2011-01-01

    A novel approach for the immediate sealing of traumatic wounds is under development. A portable microwave generator and handheld antenna are used to seal wounds, binding the edges of the wound together using a biodegradable protein sealant or solder. This method could be used for repairing wounds in emergency settings by restoring the wound surface to its original strength within minutes. This technique could also be utilized for surgical purposes involving solid visceral organs (i.e., liver, spleen, and kidney) that currently do not respond well to ordinary surgical procedures. A miniaturized microwave generator and a handheld antenna are used to deliver microwave energy to the protein solder, which is applied to the wound. The antenna can be of several alternative designs optimized for placement either in contact with or in proximity to the protein solder covering the wound. In either case, optimization of the design includes the matching of impedances to maximize the energy delivered to the protein solder and wound at a chosen frequency. For certain applications, an antenna could be designed that would emit power only when it is in direct contact with the wound. The optimum frequency or frequencies for a specific application would depend on the required depth of penetration of the microwave energy. In fact, a computational simulation for each specific application could be performed, which would then match the characteristics of the antenna with the protein solder and tissue to best effect wound closure. An additional area of interest with potential benefit that remains to be validated is whether microwave energy can effectively kill bacteria in and around the wound. Thus, this may be an efficient method for simultaneously sterilizing and closing wounds.

  9. Long-term results of external auditory canal closure and mastoid obliteration in cochlear implantation after radical mastoidectomy: a clinical and radiological study.

    Science.gov (United States)

    Vincenti, Vincenzo; Pasanisi, Enrico; Bacciu, Andrea; Bacciu, Salvatore

    2014-08-01

    Cochlear implant candidates with mastoid cavity present a significant challenge to safe cochlear implantation because of possible spread of infection to the inner ear as well as an increased risk of electrode array extrusion. Closure of the external auditory canal is one of the several surgical techniques utilized to block the potential entry routes for infection and to protect the implanted device. The main concern after external auditory canal closure is the risk of developing a cholesteatoma, which can lead to an asymptomatic erosion of the temporal bone and/or cochlear implant failure. In this study we present the results of very long-term (mean 12 years) clinical and radiological follow-up in 12 patients who underwent external auditory canal closure associated with mastoid and Eustachian tube obliteration to facilitate cochlear implantation. To date, with a mean ± SD follow-up of 12 ± 4.7 years (range 5-21 years), the only complication experienced was the breakdown of the EAC closure in one patient, successfully treated by performing a rotation skin flap. The results of this study confirmed that external auditory canal closure is a reliable technique in cochlear implantation after radical mastoidectomy provided that a rigorous surgical technique is performed. A right balance between the need to reduce costs and to avoid unnecessary doses of radiation to patients and the task of a radiological surveillance may be represented by performing computed tomography 12-18 months postoperatively and then, only if clinically warranted.

  10. Fracture mechanics analyses of partial crack closure in shell structures

    Science.gov (United States)

    Zhao, Jun

    2007-12-01

    This thesis presents the theoretical and finite element analyses of crack-face closure behavior in shells and its effect on the stress intensity factor under a bending load condition. Various shell geometries, such as spherical shell, cylindrical shell containing an axial crack, cylindrical shell containing a circumferential crack and shell with double curvatures, are all studied. In addition, the influence of material orthotropy on the crack closure effect in shells is also considered. The theoretical formulation is developed based on the shallow shell theory of Delale and Erdogan, incorporating the effect of crack-face closure at the compressive edges. The line-contact assumption, simulating the crack-face closure at the compressive edges, is employed so that the contact force at the closure edges is introduced, which can be translated to the mid-plane of the shell, accompanied by an additional distributed bending moment. The unknown contact force is computed by solving a mixed-boundary value problem iteratively, that is, along the crack length, either the normal displacement of the crack face at the compressive edges is equal to zero or the contact pressure is equal to zero. It is found that due to the curvature effects crack closure may not always occur on the entire length of the crack, depending on the direction of the bending load and the geometry of the shell. The crack-face closure influences significantly the magnitude of the stress intensity factors; it increases the membrane component but decreases the bending component. The maximum stress intensity factor is reduced by the crack-face closure. The significant influence of geometry and material orthotropy on rack closure behavior in shells is also predicted based on the analytical solutions. Three-dimensional FEA is performed to validate the theoretical solutions. It demonstrates that the crack face closure occurs actually over an area, not on a line, but the theoretical solutions of the stress intensity

  11. "Distinvar" device

    CERN Multimedia

    CERN PhotoLab

    1965-01-01

    The alignment of one of the accelerator magnets being checked by the AR Division survey group. A "distinvar" device, invented by the group, using calibrated invar wires stretched between the fixed survey pillar (on the left) and a fixed point on the magnet. In two days it is thus possible to measure the alignment of the 100 magnets with an accuracy better than 1/10.

  12. Magnetohydrodynamic device

    Energy Technology Data Exchange (ETDEWEB)

    Gorlin, S.M.; Ljubimov, G.A.; Bitjurin, V.A.; Kovbasjuk, V.I.; Maximenko, V.I.; Medin, S.A.; Barshak, A.E.

    1979-12-25

    A magnetohydrodynamic device having a duct for a conducting gas to flow at an angle with the direction of the magnetic field induction vector is described. The duct is situated in the magnetic system and is provided with a plurality of electrodes adapted to interact electrically with the gas, whereas the cross-sectional shape of the duct working space is bounded by a closed contour formed by a curve inscribed into a rectangle. 1 claim.

  13. Transcatheter Closure of Atrial Septal Defect with Amplatzer Septal Occluder in Adults: Immediate, Short, and Intermediate-Term Results

    Directory of Open Access Journals (Sweden)

    Majid Dehghani

    2011-05-01

    Full Text Available Background: The transcatheter closure of the atrial septal defect (ASD has become an alternative technique to surgical procedures. The aim of this study was to assess the immediate, short, and intermediate-term results of the transcatheter closure of the secundum ASD with the Amplatzer Septal Occluder (ASO in adult Iranian patients.Methods: Between December 2004 and July 2008, the transcatheter closure of the ASD using the ASO was attempted in 58consecutive, adult patients. The mean age of the patients was 37.1 ± 12.7 years (range = 19 - 75 years.All the procedures were performed under local anesthesia with transthoracic or transesophageal echocardiography and fluoroscopic guidance. The stretched diameter of the ASD was determined with a balloon sizing catheter, and device selection was based on and matched to the stretched diameter of the septal defect.Transthoracic echocardiography was performed immediately after the release of the device and before discharge.Further follow-up at one month, six months, and yearly thereafter included physical examination, electrocardiography, andtransthoracic echocardiography.Results: The mean ASD diameter, as measured by esophageal echocardiography, was 24.8 ± 5.4 mm (range = 13 - 34 mm.The mean stretched diameter, as measured by the balloon catheter, was 27.1 ± 6.4 mm (range = 12.5 - 39 mm. Deploymentof the ASO was successful in 52 (89.6% patients and failed in 6 (10.4%. Four patients experienced severe complications,1 had tamponade requiring drainage, 2 had device embolization to the left atrium and right ventricular outflow tract, and 1 had late wire fracture (surgical removal and repair of the ASD. The position of two large devices (34 mm and 36 mm was considered unsuitable and unstable after implantation and resulted in the removal of these devices.Minor complications included transient complete atrioventricular block in 1 patient, paroxysmal supra tachycardia in 3 patients, atrial flutter in 1 patient

  14. Assessing the contribution of water to the mass closure of PM10

    Science.gov (United States)

    Perrino, C.; Catrambone, M.; Farao, C.; Canepari, S.

    2016-09-01

    The data obtained during a number of field studies aimed at determining the chemical composition of atmospheric particulate matter (PM) have shown that the measurement of the main PM components (main elements, ions, elemental carbon, organic carbon) was generally sufficient to obtain a reasonable mass closure. Notwithstanding, a wide gap between PM mass concentration and reconstructed mass was observed in two peculiar environmental conditions: desert dust intrusion and severe atmospheric stability episodes characterized by very high ammonium nitrate concentration. In these two cases, the mass closure improved significantly by adding the concentration of PM-bound water. Water was determined by using a coulometric Karl-Fisher system equipped with a controlled heating device; the method was able to separate different water contributions released in different temperature ranges from 50 to 250 °C. In our field studies the amount of water associated to ammonium salts in winter stability conditions was mostly dependent on ammonium nitrate concentration and constituted up to 22% of the total PM10 mass; the specific water contribution linked to ammonium salts (released in the temperature range 180-250 °C) constituted up to 30% of the ammonium nitrate mass. It was confirmed that in these extreme conditions quartz and Teflon filters behave differently: when measured on quartz filters, PM concentration was lower than on Teflon, the mass closure was satisfactory and the concentration of water was presumably very low. In the case of desert dust episodes, water was up to 10% of total PM10 mass; the specific water contribution linked to desert dust (released in the temperature range 100-180 °C) constituted about 5% of the mass of soil components. In other environmental situations, such as urban environments, marine atmosphere and rural areas, the concentration of PM-bound water was below 2-3 μg/m3.

  15. Single-shell tank closure work plan. Revision A

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-06-01

    In January 1994, the Hanford Federal Facility Agreement and Conset Order (Tri-Party Agreement) was amended to reflect a revised strategy for remediation of radioactive waste in underground storage tanks. These amendments include milestones for closure of the single-shell tank (SST) operable units, to be initiated by March 2012 and completed by September 2024. This SST-CWP has been prepared to address the principal topical areas identified in Tri-Party Agreement Milestone M-45-06 (i.e., regulatory pathway, operable unit characterization, waste retrieval, technology development, and a strategy for achieving closure). Chapter 2.0 of this SST-CWP provides a brief description of the environmental setting, SST System, the origin and characteristics of SST waste, and ancillary equipment that will be remediated as part of SST operable unit closure. Appendix 2A provides a description of the hydrogeology of the Hanford Site, including information on the unsaturated sediments (vadose zone) beneath the 200 Areas Plateau. Chapter 3.0 provides a discussion of the laws and regulations applicable to closure of the SST farm operable units. Chapter 4.0 provides a summary description of the ongoing characterization activities that best align with the proposed regulatory pathway for closure. Chapter 5.0 describes aspects of the SST waste retrieval program, including retrieval strategy, technology, and sequence, potential tank leakage during retrieval, and considerations of deployment of subsurface barriers. Chapter 6.0 outlines a proposed strategy for closure. Chapter 7.0 provides a summary of the programs underway or planned to develop technologies to support closure. Ca. 325 refs.

  16. Epithelial gap closure governed by forces and geometry

    Science.gov (United States)

    Ladoux, Benoit

    The closure of gaps within epithelia is crucial to maintain the integrity and the homeostasis of the tissue during wound healing or cell extrusion processes. Cells mediate gap closure through either the assembly of multicellular actin-based contractile cables (purse-string contraction) or the protrusive activity of border cells into the gap (cell crawling). I will present experimental data and numerical modeling that show how these mechanisms can mutually interact to promote efficient epithelial gap closure and how mechanical constraints can regulate these mechanisms. I will first present how geometrical constraints dictate mechanisms of epithelial gap closure. We determine the importance of tissue shape during closure and the role of curvature of cell boundaries in this process. An essential difference between the two closure mechanisms is that cell crawling always pulls the edge of the tissue forward (i.e. towards the gap) while purse string pulls the edge forward or backwards depending on the local geometry. Our study demonstrates how the interplay between these two mechanisms is crucial for closing gaps and wounds, which naturally come in arbitrary shapes. Then I will focus on epithelial closure mechanism during cell extrusion. Within confluent cell layers, cellular motions coupled between neighbors are tightly regulated by the packing density of the epithelium inducing drastic changes in the dynamics of these tissues. I will show how cell density and tissue mechanics regulate the extrusion of cells within a confluent epithelial cell sheet, simultaneously measuring collective movements and traction forces. Epithelial packing and collective cell dynamics dictate the modes of cellular extrusions from lamellipodia crawling of the neighboring cells at low densities to coordinated actin-based contractile purse-string mechanism at higher density.

  17. Percutaneous transcatheter closure of atrial septal defects: initial single-centre experience and follow-up results. Initial experience with three-dimensional echocardiography.

    Science.gov (United States)

    De Ridder, Serge; Suttorp, Maarten-Jan; Ernst, Sjef M P G; Six, Jacob A; Mannaerts, Herman F J; Kamp, Otto; Plokker, Thijs H W M; Jaarsma, Wybren

    2005-04-01

    Registry to report our single-centre experience in closing defects of the atrial septum. Between 1996 and 2001, transcatheter device closure of significant atrial septal defects was performed in 32 adults (mean age 45.1 years, range from 15 to 76 years), using different device types. Six patients had a patent foramen ovale (PFO) and 26 patients had a secundum atrial septal defect (ASD II). Defects were selected by means of two-dimensional transoesophageal echocardiography (2D TOE). For 12 defects additional three-dimensional transoesophageal echocardiography (3D TOE) was performed. Mean balloon-stretched diameter was 19.3 mm (range from 11 to 24 mm). A device was successfully placed in all PFO patients (100%) without complications at follow-up. Successful immediate device placement occurred in 24 out of 26 ASD patients. Two immediate placement failures, 1 device embolisation and 1 device non-fixation, occurred and required urgent surgery. There was 1 patient with pericardial effusion after the intervention, requiring pericardiocentesis. Three late placement failures occurred: 2 device embolisations and 1 device dislocation. Clinical success after 3 to 6 months follow-up, defined as the absence of shunt or small shunt, was achieved in all 6 PFO patients and in 21 out of 23 ASD patients (1 device embolisation, requiring surgery, occurred before follow-up was completed). Two patients with significant shunt, 1 late device dislocation and 1 late device embolisation, underwent elective surgery. For patient selection, 3D TOE proved useful in the evaluation of large and/or complex defects. Transcatheter device closure of carefully selected atrial septal defects is an alternative to surgery. Although the results are promising, surgical back-up is often needed.

  18. Long-term cavity closure in non-linear rocks

    Science.gov (United States)

    Cornet, Jan; Dabrowski, Marcin; Schmid, Daniel Walter

    2017-08-01

    The time dependent closure of pressurized cavities in viscous rocks due to far-field loads is a problem encountered in many applications like drilling, cavity abandonment and porosity closure. The non-linear nature of the flow of rocks prevents the use of simple solutions for hole closure and calls for the development of appropriate expressions reproducing all the dependencies observed in nature. An approximate solution is presented for the closure velocity of a pressurized cylindrical cavity in a non-linear viscous medium subjected to a combined pressure and shear stress load in the far field. The embedding medium is treated as homogeneous, isotropic, and incompressible and follows a Carreau viscosity model. We derive analytical solutions for the end-member cases of the pressure and shear loads. The exact analytical solution for pressure loads shows that the closure velocity vR is given by the implicit expression {Δ p}/{2{μ _0D_{II}^*}} = - 1/2B( {{v_R^2}/{RD_{II^* + v_R^2}};1/2, - 1/{2n}} ), where Δp is the pressure load, R is the hole radius, B is the incomplete beta function, and μ0, D_{II}^*, n are, respectively, the threshold viscosity, transition rate and stress exponent of the Carreau model. The closure velocity is dominated by the linear mechanism under pressure loads smaller than 1.8{μ _0}D_{II}^* and by the non-linear one under large pressure loads. In the non-linear regime, pressure variations support an increasing part of the load with increasing degree of non-linearity. The decay of the stress perturbation in the non-linear zone varies as r- 2/n where r is the radial distance to the hole. A solution for the maximum closure velocity at the cavity rim vRmax under far-field shear is given: v_{R\\max} = ( 1 + {\\overline {M_s}} ^{-1/2})R\\overline D_{II}, where \\overline {M_s} = (1 + {\\overline {D_{II}} }^2 \\big/ {nD{_{II}^*}^2}) \\big/ ( 1 + {\\overline {D_{II}}^2} \\big/ D{_{II}^*}^2) and \\overline {D_{II}} is the second invariant of the far

  19. Transumbilical endoscopic technique for complete closure of inguinal hernias in female pediatric patients

    Science.gov (United States)

    Zhou, Xuewu; Qi, Xi; Jiang, Bing; Sha, Yongliang; Song, Daiqiang

    2017-01-01

    Laparoscopic percutaneous extraperitoneal closure of inguinal hernia with variable devices as an effective technique in minimal-access surgery for pediatric inguinal hernias in children was investigated in the present study. A Veress needle was inserted into the abdomen. Trocars, laparoscope and needle holder were placed through the umbilical incision. Under laparoscopic monitoring, a round needle was introduced into the peritoneal cavity through the anterior abdominal wall. The end of the suture inside the peritoneal cavity was left outside the peritoneal cavity in favor of ligation. The needle was passed through the peritoneum to place an extraperitoneal purse-string suture around the internal inguinal ring, counterclockwise on the left and clockwise on the right. The needle was then passed back into the peritoneal cavity and out through the abdominal wall, and the needle ends of the stitch were cut. The ends of the suture were tied. We described a technique used for transumbilical endoscopic closure of pediatric inguinal hernias in girls. This technique is simple and can be performed quickly. The cosmetic result is excellent because the two umbilical incisions are only 5-mm long, which make it possible to perform surgery without a visible scar. We performed this procedure in over 96 patients and have had no recurrences. Thus, this method may become the laparoscopic repair of choice for females with inguinal hernias. PMID:28123465

  20. Research on the Closure of iOS%iOS 封闭性研究

    Institute of Scientific and Technical Information of China (English)

    甘泉; 宫蕾; 李刚

    2013-01-01

    IOS,which is a kind of hand-held devices operating system developed by apple Inc.,has the balance of power in mobile platform market.Closure is its main characteristic and is controversial.Through contrast method,both the advantages and the problems of its closure were objectively analyzed.At last the author states the viewpoint of its development tendency.%  iOS 是苹果公司开发的手持设备操作系统,在移动平台中具有具足轻重的地位。封闭性是其最主要特征,并使其备受争议。通过对比的方法,对其封闭性的优势和存在问题进行了客观分析,并对其发展趋势阐述了作者观点。

  1. Experimental Investigation on the Pressure Characteristics of Cavity Closure Region

    Institute of Scientific and Technical Information of China (English)

    Yadong Wang; Xulong Yuan; Yuwen Zhang

    2012-01-01

    The most complicated component in cavitating flow and pressure distribution is the flow in the cavity closure line.The cavitating flow and pressure distribution provide critical aspects of flow field details in the region.The integral of pressure results of the hydrodynamic forces,indicate domination in the design of a supercavitating vehicle.An experiment was performed in a water tunnel to investigate the pressure characteristics of the cavity closure region.Ventilation methods were employed to generate artificial cavity,and the ventilation rate was adjusted accordingly to obtain the desired cavity length.An array of pressure transducers was laid down the cavity closure line to capture pressure distribution in this region.The experimental results show that there is a pressure peak in the cavity closure region,and the rise rate of pressure in space tends to be higher in the upwind side when the flow is non-axisymmetric.The transient pressure variations during the cavity formation procedure were also present.The method of measurement in this paper can be referenced by engineers.The result helps to study the flow pattern of cavity closure region,and it can also be used to analyze the formation of supercavitating vehicle hydrodynamics.

  2. Cutaneous wound closure materials: an overview and update.

    Science.gov (United States)

    Al-Mubarak, Luluah; Al-Haddab, Mohammed

    2013-10-01

    On a daily basis, dermasurgeons are faced with different kinds of wounds that have to be closed. With a plethora of skin closure materials currently available, choosing a solution that combines excellent and rapid cosmetic results with practicality and cost-effectiveness can be difficult, if not tricky. We aimed to review the available skin closure materials over the past 20 years and the scientific claims behind their effectiveness in repairing various kinds of wounds. The two authors independently searched and scrutinised the literature. The search was performed electronically using Pub Med, the Cochrane Database, Google Scholar and Ovid as search engines to find articles concerning skin closure materials written since 1990. Many factors are involved in the choice of skin closure material, including the type and place of the wound, available materials, physician expertise and preferences, and patient age and health. Evidence-based main uses of different skin closure materials are provided to help surgeons choose the appropriate material for different wounds.

  3. Congenital Abdominal Wall Defects: Staged closure by Dual Mesh.

    Science.gov (United States)

    Risby, Kirsten; Jakobsen, Marianne Skytte; Qvist, Niels

    2016-01-01

    To evaluate the clinical utility of GORE® DUALMESH (GDM) in the staged closure of large congenital abdominal wall defects. Data of patients with congenital abdominal wall defects managed with GDM was analyzed for outcome regarding complete fascial closure; mesh related complications; and post-discharge gastrointestinal surgery. GDM was placed in 34 (gastroschisis=27, omphalocele=7) patients during the study period. Complete closure of the fascia was obtained in one patient with omphalocele and in 22 patients with gastroschisis. Mesh related surgical complications were seen in five (15%) children: four had detachment of the mesh and one patient developed abdominal compartment syndrome. Mesh related clinical infection was observed in five children. In hospital mortality occurred in four cases (2 gastroschisis and 2 omphalocele) and was not procedure-related. Of the 30 children discharged, 28 (82%) were still alive. At follow-up, three patients (10%) were operated for a minor ventral hernia and 4 children were operated (laparotomy and adhesionolysis) for adhesive intestinal obstruction. Staged closure with GDM is a safe alternative when primary fascial closure is difficult.

  4. Design, production and initial state of the closure

    Energy Technology Data Exchange (ETDEWEB)

    2010-12-15

    The report is included in a set of Production reports, presenting how the KBS-3 repository is designed, produced and inspected. The production reports are included in the safety report for the KBS-3 repository and repository facility. The report provides input on the initial state of the closure and plugs in underground openings other than deposition tunnels for the assessment of the long-term safety, SR-Site. The initial state refers to the properties of the engineered barriers once they have been finally placed in the KBS-3 repository and will not be further handled within the repository facility. In addition, the report provides some input to the operational safety report, SR-Operation, on how the closure and plugs shall be handled and installed. The report presents the design premises and reference designs of the closure and plugs and verifies their conformity to the design premises. It also briefly deals with the production of the closure and plugs. Finally, the initial state of the closure and plugs and their conformity to the reference designs and design premises are presented

  5. Cutaneous wound closure materials: An overview and update

    Directory of Open Access Journals (Sweden)

    Luluah Al-Mubarak

    2013-01-01

    Full Text Available Introduction: On a daily basis, dermasurgeons are faced with different kinds of wounds that have to be closed. With a plethora of skin closure materials currently available, choosing a solution that combines excellent and rapid cosmetic results with practicality and cost-effectiveness can be difficult, if not tricky. Objectives: We aimed to review the available skin closure materials over the past 20 years and the scientific claims behind their effectiveness in repairing various kinds of wounds. Materials and Methods: The two authors independently searched and scrutinised the literature. The search was performed electronically using Pub Med, the Cochrane Database, Google Scholar and Ovid as search engines to find articles concerning skin closure materials written since 1990. Conclusion: Many factors are involved in the choice of skin closure material, including the type and place of the wound, available materials, physician expertise and preferences, and patient age and health. Evidence-based main uses of different skin closure materials are provided to help surgeons choose the appropriate material for different wounds.

  6. Electrooptical devices

    Science.gov (United States)

    Hurwitz, C. E.

    1980-03-01

    This report covers work carried out with support of the Department of the Air Force during the period 1 October 1979 through 31 March 1980. A part of this support was provided by the Rome Air Development Center. CW operation at temperatures up to 55 C has been achieved for GaInAsP/InP double-heterostructure (DH) lasers emitting at 1.5 micrometers, which were grown without a GaInAsP buffer layer. These devices are of interest for use as sources in fiber-optics communications systems, since the lowest transmission loss reported for fused-silica optical fibers occurs at 1.55 micrometers. Surface passivation techniques developed for InP and GaInAsP avalanche photodiodes have resulted in reductions of dark current as large as four orders of magnitude, to values as low as .0000016 A/sq cm at 0.9 V(b) where V(b) is the breakdown voltage. Devices consisting entirely of InP have been passivated with plasma-deposited Si3N4, and those with a GaInAsP layer but with the p-n junction in InP have been passivated with polyimide. Neither of these techniques successfully reduces dark currents in devices with the p-n junction in the GaInAsP, but a film of photoresist sprayed with SF6 as the propellant has given excellent results. The electrical characteristics in InP ion implanted with Sn, Ge, Si, and C have been investigated. All of these column IV elements yielded n-type conductivity and Sn, Ge, and Si showed high electrical activation; however, implanted C was found to have a net electrical activation of only about 5 percent.

  7. Transvenous closure of large aortopulmonary collateral

    Directory of Open Access Journals (Sweden)

    Parag W Barwad

    2014-01-01

    Full Text Available Aortopulmonary collaterals (APCs are occluded either preoperatively or at the time of cardiac surgery in patients with pulmonary atresia and ventricular septal defect (PAVSD. If left untreated, APCs are an important cause of deterioration in the early postoperative period. We present here an unusual case with a large residual APC causing refractory low-output state in the early postoperative period. Usual arterial approach failed due to extensive angulation with ostial narrowing. The large residual APC was successfully closed with an Amplatzer duct occluder (ADO device delivered through the transvenous route.

  8. Left Atrial Appendage Closure for Atrial Fibrillation Is Safe and Effective After Intracranial or Intraocular Hemorrhage.

    Science.gov (United States)

    Fahmy, Peter; Spencer, Ryan; Tsang, Michael; Gooderham, Peter; Saw, Jacqueline

    2016-03-01

    Atrial fibrillation (AF) affects 1%-2% of the general population and 13% of individuals older than 80 years of age. Anticoagulation has been the mainstay therapy to reduce stroke risk. Patients with previous intracranial hemorrhage (ICH) or intraocular hemorrhage (IOH) are at increased risk of recurrence if anticoagulation is continued or initiated. Left atrial appendage (LAA) closure may obviate the need for long-term anticoagulation in these patients. We report our consecutive series of patients with nonvalvular AF with previous ICH or IOH who underwent LAA closure with the AMPLATZER Cardiac Plug (ACP; St Jude Medical, St Paul, MN), AMPLATZER Amulet, or WATCHMAN (Boston Scientific, Natick, MA) device. Demographics, clinical status, procedural outcomes, and complications were collected at baseline, during the procedure, at 3 months, at 1 year, and annually thereafter. Twenty-six patients with previous ICH (n = 24) or IOH (n = 2) underwent LAA closure (9 with the ACP, 3 with the Amulet, and 7 with the WATCHMAN). The mean age was 76 ± 7 years, and 61.5% were men with a mean CHADS2 (Congestive Heart Failure, Hypertension, Age, Diabetes, Stroke/Transient Ischemic Attack) score of 3.2 ± 1.4 and CHA2DS2-VASc (Congestive Heart Failure, Hypertension, Age [≥ 75 years], Diabetes, Stroke/Transient Ischemic Attack, Vascular Disease, Age [65-74 years], Sex [Female] score) of 4.9 ± 1.7. No procedure-related complications occurred. Mean follow-up was 11.9 ± 13.3 months. One patient died at 13 months (this death was not related to the procedure), and 1 patient had a transient ischemic attack at 20.6 months after the procedure. No ischemic stroke, haemorrhagic stroke, or bleeding problems occurred during follow-up. In our consecutive series, LAA closure was found to be safe and effective in patients with AF and a history of ICH or IOH. Copyright © 2016 Canadian Cardiovascular Society. Published by Elsevier Inc. All rights reserved.

  9. Scalable devices

    KAUST Repository

    Krüger, Jens J.

    2014-01-01

    In computer science in general and in particular the field of high performance computing and supercomputing the term scalable plays an important role. It indicates that a piece of hardware, a concept, an algorithm, or an entire system scales with the size of the problem, i.e., it can not only be used in a very specific setting but it\\'s applicable for a wide range of problems. From small scenarios to possibly very large settings. In this spirit, there exist a number of fixed areas of research on scalability. There are works on scalable algorithms, scalable architectures but what are scalable devices? In the context of this chapter, we are interested in a whole range of display devices, ranging from small scale hardware such as tablet computers, pads, smart-phones etc. up to large tiled display walls. What interests us mostly is not so much the hardware setup but mostly the visualization algorithms behind these display systems that scale from your average smart phone up to the largest gigapixel display walls.

  10. Leaf Closure in the Venus Flytrap: An Acid Growth Response

    Science.gov (United States)

    Williams, Stephen E.; Bennett, Alan B.

    1982-12-01

    The rapid closure of leaves in the Venus flytrap (Dionaea muscipula) involves irreversible cell enlargement, which can be initiated by acidifying the cell walls to pH 4.50 and below. Leaves infiltrated with neutral buffers that keep the pH above 4.50 to 4.75 will not close in response to stimulation of their trigger hairs even though the action potentials that ordinarily cause closure are produced. During the 1 to 3 seconds required for closure about 29 percent of the cellular adenosine triphosphate is lost. It is likely that this adenosine triphosphate is used in very rapid transport of hydrogen ions from the motor cells and that the movement is due to a mechanism of ``acid growth.''

  11. A computable expression of closure to efficient causation.

    Science.gov (United States)

    Mossio, Matteo; Longo, Giuseppe; Stewart, John

    2009-04-07

    In this paper, we propose a mathematical expression of closure to efficient causation in terms of lambda-calculus; we argue that this opens up the perspective of developing principled computer simulations of systems closed to efficient causation in an appropriate programming language. An important implication of our formulation is that, by exhibiting an expression in lambda-calculus, which is a paradigmatic formalism for computability and programming, we show that there are no conceptual or principled problems in realizing a computer simulation or model of closure to efficient causation. We conclude with a brief discussion of the question whether closure to efficient causation captures all relevant properties of living systems. We suggest that it might not be the case, and that more complex definitions could indeed create crucial some obstacles to computability.

  12. Phase closure nulling: results from the 2009 campaign

    Science.gov (United States)

    Duvert, Gilles; Malbet, Fabien; Chelli, Alain; Millan-Gabet, Rafael; Monnier, John D.; Schaefer, Gail H.

    2010-07-01

    We present here a new observational technique, Phase Closure Nulling (PCN), which has the potential to obtain very high contrast detection and spectroscopy of faint companions to bright stars. PCN consists in measuring closure phases of fully resolved objects with a baseline triplet where one of the baselines crosses a null of the object visibility function. For scenes dominated by the presence of a stellar disk, the correlated flux of the star around nulls is essentially canceled out, and in these regions the signature of fainter, unresolved, scene object(s) dominates the imaginary part of the visibility in particular the closure phase. We present here the basics of the PCN method, the initial proof-of-concept observation, the envisioned science cases and report about the first observing campaign made on VLTI/AMBER and CHARA/MIRC using this technique.

  13. Phase Closure Nulling: results from the 2009 campaign

    CERN Document Server

    Duvert, Gilles; Chelli, Alain; Millan-Gabet, Rafael; Monnier, John D; Schaefer, Gail H

    2010-01-01

    We present here a new observational technique, Phase Closure Nulling (PCN), which has the potential to obtain very high contrast detection and spectroscopy of faint companions to bright stars. PCN consists in measuring closure phases of fully resolved objects with a baseline triplet where one of the baselines crosses a null of the object visibility function. For scenes dominated by the presence of a stellar disk, the correlated flux of the star around nulls is essentially canceled out, and in these regions the signature of fainter, unresolved, scene object(s) dominates the imaginary part of the visibility in particular the closure phase. We present here the basics of the PCN method, the initial proof-of-concept observation, the envisioned science cases and report about the first observing campaign made on VLTI/AMBER and CHARA/MIRC using this technique.

  14. INTEC CPP-603 Basin Water Treatment System Closure: Process Design

    Energy Technology Data Exchange (ETDEWEB)

    Kimmitt, Raymond Rodney; Faultersack, Wendell Gale; Foster, Jonathan Kay; Berry, Stephen Michael

    2002-09-01

    This document describes the engineering activities that have been completed in support of the closure plan for the Idaho Nuclear Technology and Engineering Center (INTEC) CPP-603 Basin Water Treatment System. This effort includes detailed assessments of methods and equipment for performing work in four areas: 1. A cold (nonradioactive) mockup system for testing equipment and procedures for vessel cleanout and vessel demolition. 2. Cleanout of process vessels to meet standards identified in the closure plan. 3. Dismantlement and removal of vessels, should it not be possible to clean them to required standards in the closure plan. 4. Cleanout or removal of pipelines and pumps associated with the CPP-603 basin water treatment system. Cleanout standards for the pipes will be the same as those used for the process vessels.

  15. Infering and Calibrating Triadic Closure in a Dynamic Network

    Science.gov (United States)

    Mantzaris, Alexander V.; Higham, Desmond J.

    In the social sciences, the hypothesis of triadic closure contends that new links in a social contact network arise preferentially between those who currently share neighbours. Here, in a proof-of-principle study, we show how to calibrate a recently proposed evolving network model to time-dependent connectivity data. The probabilistic edge birth rate in the model contains a triadic closure term, so we are also able to assess statistically the evidence for this effect. The approach is shown to work on data generated synthetically from the model. We then apply this methodology to some real, large-scale data that records the build up of connections in a business-related social networking site, and find evidence for triadic closure.

  16. Self-Energy Closure for Inhomogeneous Turbulent Flows and Subgrid Modeling

    Directory of Open Access Journals (Sweden)

    Jorgen S. Frederiksen

    2012-04-01

    Full Text Available A new statistical dynamical closure theory for general inhomogeneous turbulent flows and subgrid modeling is presented. This Self-Energy (SE closure represents all eddy interactions through nonlinear dissipation or forcing ‘self-energy’ terms in the mean-field, covariance and response function equations. This makes the renormalization of the bare dissipation and forcing, and the subgrid modeling problem, transparent. The SE closure generalizes the quasi-diagonal direct interaction closure to allow for more complex interactions. The SE closure is applicable to flows in different geometries, is exact near maximum entropy states corresponding to canonical equilibrium, and provides a framework for deriving simpler realizable closures.

  17. Iatrogenic erosion of the septum primum resulting in an atrial septal defect with left-to-right shunt: a rare pitfall of patent foramen ovale percutaneous closure.

    Science.gov (United States)

    Scacciatella, Paolo; Biava, Lorenza Michela; Marra, Sebastiano

    2014-09-01

    Iatrogenic erosion of the septum primum after foramen ovale closure is an anecdotal event. We report the case of a 39-year-old woman admitted to our institution for multifocal cryptogenic cerebral ischemia and a patent foramen ovale (PFO) associated with an aneurysm of the septum primum. The patient underwent percutaneous closure of the PFO with an Amplatzer PFO Occluder device. At the 6-months follow up, the device was in the right position, but a jagged defect of the septum primum and evidence of significant left-to-right shunting was detected. The atrial septal defect was then repaired by a surgical approach. Although this event is not life-threatening, it should be considered as a therapeutic pitfall, resulting in a risk of paradoxical embolism recurrences and long-term hemodynamic impairment. © 2013 Wiley Periodicals, Inc.

  18. Practical microwave electron devices

    CERN Document Server

    Meurant, Gerard

    2013-01-01

    Practical Microwave Electron Devices provides an understanding of microwave electron devices and their applications. All areas of microwave electron devices are covered. These include microwave solid-state devices, including popular microwave transistors and both passive and active diodes; quantum electron devices; thermionic devices (including relativistic thermionic devices); and ferrimagnetic electron devices. The design of each of these devices is discussed as well as their applications, including oscillation, amplification, switching, modulation, demodulation, and parametric interactions.

  19. Transcatheter Closure of Patent Foramen Ovale: A Single Center Experience

    Science.gov (United States)

    Milev, Ivan; Zafirovska, Planinka; Zimbakov, Zan; Idrizi, Shpend; Ampova-Sokolov, Vilma; Gorgieva, Emilija; Ilievska, Liljana; Tosheski, Goce; Hristov, Nikola; Georgievska-Ismail, Ljubica; Anguseva, Tanja; Mitrev, Zan

    2016-01-01

    BACKGROUND: Percutaneous transcatheter closure (PTC) of patent foramen ovale (PFO) is implicated in cryptogenic stroke, transitional ischemic attack (TIA) and treatment of a migraine. AIM: Our goal was to present our experience in the interventional treatment of PFO, as well as to evaluate the short and mid-term results in patients with closed PFO. MATERIAL AND METHODS: Transcatheter closure of PFO was performed in 52 patients (67.3% women, mean age 40.7 ± 11.7 years). Patients were interviewed for subjective grading of the intensity of headaches before and after the PFO closure. RESULTS: During 2 years of follow-up, there was no incidence of new stroke, TIA and/or syncope. Follow-up TCD performed in 35 patients showed complete PFO closure in 20 patients (57.1%). Out of 35 patients, 22 (62.9%) reported having a migraine before the procedure with an intensity of headaches at 8.1 ± 1.9 on a scale from 1 to 10. During 2 years of follow-up, symptoms of a migraine disappeared in 4 (18.2%) and the remaining 18 patients reported the significant decrease in intensity 4.8 ± 2.04 (p = 0.0001). In addition, following PFO closure the incidence of the headaches decreased significantly (p = 0.0001). CONCLUSIONS: Percutaneous transcatheter closure of PFO is a safe and effective procedure showing mid-term relief of neurological symptoms in patients as well as significant reduction of migraine symptoms. PMID:28028400

  20. close: Closure of patent foramen ovale, oral anticoagulants or antiplatelet therapy to prevent stroke recurrence: Study design.

    Science.gov (United States)

    Mas, Jean-Louis; Derumeaux, Geneviève; Amarenco, Pierre; Arquizan, Caroline; Aubry, Pierre; Barthelet, Martine; Bertrand, Bernard; Brochet, Eric; Cabanes, Laure; Donal, Erwan; Dubois-Randé, Jean-Luc; Durand-Zaleski, Isabelle; Ernande, Laura; Finet, Gérard; Fraisse, Alain; Giroud, Maurice; Guérin, Patrice; Habib, Gilbert; Juliard, Jean-Michel; Leys, Didier; Lièvre, Michel; Lusson, Jean-René; Marcon, François; Michel, Patrick; Moulin, Thierry; Mounier-Vehier, François; Pierard, Luc; Piot, Christophe; Rey, Christian; Rodier, Gilles; Roudaut, Raymond; Schleich, Jean-Marc; Teiger, Emmanuel; Turc, Guillaume; Vuillier, Fabrice; Weimar, Christian; Woimant, France; Chatellier, Gilles

    2016-08-01

    Currently available data do not provide definitive evidence on the comparative benefits of closure of patent foramen ovale, oral anticoagulants and antiplatelet therapy in patients with patent foramen ovale-associated cryptogenic stroke To assess whether transcatheter patent foramen ovale closure plus antiplatelet therapy is superior to antiplatelet therapy alone and whether oral anticoagulant therapy is superior to antiplatelet therapy, for secondary stroke prevention in patients aged 16 to 60 years with a large patent foramen ovale or a patent foramen ovale associated with an atrial septal aneurysm, and an otherwise unexplained ischaemic stroke or retinal ischaemia. Six hundred and sixty-four patients were included in the study. CLOSE is an academic-driven, multicentre, randomized, open-label, three-group, superiority trial with blinded adjudication of outcome events. The trial has been registered with Clinical Trials Register (Clinicaltrials.gov, NCT00562289). Patient recruitment started in December 2007. Patient follow-up will continue until December 2016. Expected mean follow-up = 5.6 years. The primary efficacy outcome is the occurrence of fatal or nonfatal stroke. Safety outcomes include fatal, life-threatening or major procedure- or device-related complications and fatal, life-threatening or major haemorrhagic complications. CLOSE is the first specifically designed trial to assess the superiority of patent foramen ovale closure over antiplatelet therapy alone and the superiority of oral anticoagulants over antiplatelet therapy to prevent stroke recurrence in patients with patent foramen ovale-associated cryptogenic stroke. © 2016 World Stroke Organization.

  1. Ultrasonographic features of vascular closure devices: initial and 6-month follow-up results

    Directory of Open Access Journals (Sweden)

    Hye Jung Choo

    2014-10-01

    Initial ultrasonographic evaluation reflected the unique structure of each VCD, with most of them being easily distinguishable. Follow-up ultrasonography revealed various changes in the affected vessels.

  2. An annulus fibrosus closure device based on a biodegradable shape-memory polymer network

    NARCIS (Netherlands)

    Sharifi, Shahriar; van Kooten, Theo G.; Kranenburg, Hendrik-Jan C.; Meij, Bjorn P.; Behl, Marc; Lendlein, Andreas; Grijpma, Dirk W.

    2013-01-01

    Injuries to the intervertebral disc caused by degeneration or trauma often lead to tearing of the annulus fibrosus (AF) and extrusion of the nucleus pulposus (NP). This can compress nerves and cause lower back pain. In this study, the characteristics of poly(D,L-lactide-co-trimethylene carbonate) ne

  3. System Dynamics and Modified Cumulant Neglect Closure Schemes

    DEFF Research Database (Denmark)

    Köylüoglu, H. Ugur; Nielsen, Søren R.K.

    Dealing with multipeaked problems, the goal of the paper is to improve the quality of the approximations for the expectations appearing in the differential equations written for the statistical moments of the state vector, guided by insight in the system dynamics. For systems with polynomial non......-linearities, modifications in the cumulant neglect closure scheme are suggested. The methodology is illustrated using the two wells oscillator. An error analysis is performed to compare the modified and ordinary cumulant neglect closure schemes applied at the second and fourth order levels with the exact results available....

  4. The Criteria for and Effects of Base Closures

    Science.gov (United States)

    1989-12-01

    determine how to improve federal government incentive programs designed to help overcome the sometimes adverse effect of base closures on the local...appoint an independent commission to study realignment or have the Department of Defense designate all bases as candidates for closure and begin appropriate...TV( CeO."t G,", Com Sovnqs Fbote, 33 tn LAct Dinon b Doia 1.11 TV X L Rle: Wesit IleiA 1913 566 K0 300 Fl laviot State Roth MC. CEF Stenv:ee

  5. Angle closure glaucoma following a combined blepharoplasty and ectropion repair.

    Science.gov (United States)

    Gayton, J L; Ledford, J K

    1992-01-01

    This paper reports an occurrence of angle closure glaucoma following a combined blepharoplasty and ectropion repair. We are unaware of any previous reports of such an incident. Specific to this case was the coexistence of a cataract that contributed to the narrowing of the anterior chamber. This condition, along with pupil dilation secondary to the anesthetic, precipitated a phacomorphic angle closure glaucoma attack, necessitating emergency cataract surgery. Because other procedures involve pupillary dilation as a potential side effect, we recommend an increased awareness of this potential postoperative complication.

  6. Closure Plan for Active Low Level Burial Grounds

    Energy Technology Data Exchange (ETDEWEB)

    SKELLY, W.A.

    2000-11-16

    This plan has been prepared in response to direction from the U.S. Department of Energy. The purpose of the plan is to define approaches that will be implemented to ensure protection of the public and the environment when active Low-Level Burial Grounds (LLBGs) at the Hanford Site are closed. Performance assessments for active burial grounds in the 200 East and West 200 Areas provide current estimates of potential environmental contamination and doses to the ''maximum exposed individual'' from burial ground operation and closure and compare dose estimates to performance objective dose limits for the facilities. This is an Operational Closure Plan. The intent of the guidance in DOE Order 435.1 is that this plan will be a living document, like the facility performance assessments, and will be revised periodically through the operational life of the LLBGs to reflect updated information on waste inventory. management practices, facility transition planning, schedule dates, assessments of post-closure performance, and environmental consequences. Out year dates identified in this plan are tentative. A Final Closure Plan will be prepared in the future when the timing and extent of closure-related activities for LLBGs can be established with greater certainty. After current operations at the LLBGs are concluded, this plan proposes transitioning of these facilities to the Environmental Restoration Program. This action will enable the Environmental Restoration Program to design and implement consistent and coordinated final remedial actions for active and inactive LLBGs. Active and inactive burial grounds in the 200 West and 200 East Areas are commingled. This plan describes approaches that will be implemented during Interim Closure, Final Closure, and Institutional Control Periods to prepare LLBGs for surface barriers, and the construction of barriers, as well as the scope of inspection, monitoring and maintenance practices that will be performed during

  7. Generative Power and Closure Properties of Watson-Crick Grammars

    Directory of Open Access Journals (Sweden)

    Nurul Liyana Mohamad Zulkufli

    2016-01-01

    Full Text Available We define WK linear grammars, as an extension of WK regular grammars with linear grammar rules, and WK context-free grammars, thus investigating their computational power and closure properties. We show that WK linear grammars can generate some context-sensitive languages. Moreover, we demonstrate that the family of WK regular languages is the proper subset of the family of WK linear languages, but it is not comparable with the family of linear languages. We also establish that the Watson-Crick regular grammars are closed under almost all of the main closure operations.

  8. A PDF closure model for compressible turbulent chemically reacting flows

    Science.gov (United States)

    Kollmann, W.

    1992-01-01

    The objective of the proposed research project was the analysis of single point closures based on probability density function (pdf) and characteristic functions and the development of a prediction method for the joint velocity-scalar pdf in turbulent reacting flows. Turbulent flows of boundary layer type and stagnation point flows with and without chemical reactions were be calculated as principal applications. Pdf methods for compressible reacting flows were developed and tested in comparison with available experimental data. The research work carried in this project was concentrated on the closure of pdf equations for incompressible and compressible turbulent flows with and without chemical reactions.

  9. Newborn exstrophy closure without osteotomy: Is there a role?

    Science.gov (United States)

    Inouye, Brian M; Lue, Kathy; Abdelwahab, Mahmoud; Di Carlo, Heather N; Young, Ezekiel E; Tourchi, Ali; Grewal, Mehnaj; Hesh, Christopher; Sponseller, Paul D; Gearhart, John P

    2016-02-01

    Recent articles document successful classic bladder exstrophy (CBE) closure without osteotomy. Still, many patients require osteotomy if they have a large bladder template and pubic diastasis, or non-malleable pelvis. To understand the indications and outcomes of bladder closure with and without pelvic osteotomy in patients younger than 1 month of age. An institutional database of 1217 exstrophy-epispadias patients was reviewed for CBE patients closed at the authors' institution within the first month of life. Patient demographics, closure history, pubic diastasis distance, bladder capacity, and outcomes were recorded and compared using chi-square tests between osteotomy and non-osteotomy patients. Failure was defined as bladder dehiscence, prolapse, vesicocutaneous fistula, or bladder outlet obstruction requiring reoperation. Bladder capacity >100 mL was deemed sufficient for bladder neck reconstruction (BNR). One hundred CBE patients were included for analysis: 38 closed with osteotomy (26 male, 12 female), and 62 closed without osteotomy (42 male, 20 female). There were four failed closures in the osteotomy group (2 dehiscence, 2 prolapse) and four failed closures in the non-osteotomy group (2 dehiscence, 2 prolapse). This corresponded to statistically equivalent rates of failure between the osteotomy and non-osteotomy groups (10.5% vs. 6.5%, p = 0.466). There was no statistically significant difference between the groups' ability to achieve bladder capacity sufficient for BNR (82% vs. 71%, p = 0.234). A successful primary bladder closure, regardless of the use of osteotomy, has been shown to be the single most important predictor of eventual continence. Because of the complexity of exstrophy manifestations, a multidisciplinary team approach is of the utmost importance. Based on our institutional experience, closure without osteotomy is considered when patients are osteotomy in patients considered suitable for closure by both the pediatric urologist and

  10. Entropy production rate as a constraint for collisionless fluid closures

    Science.gov (United States)

    Fleurence, E.; Sarazin, Y.; Garbet, X.; Dif-Pradalier, G.; Ghendrih, Ph.; Grandgirard, V.; Ottaviani, M.

    2006-11-01

    A novel method is proposed to construct collisionless fluid closures accounting for some kinetic properties. The first dropped fluid moment is assumed to be a linear function of the lower order ones. Optimizing the agreement between the fluid and kinetic entropy production rates is used to constrain the coefficients of the linear development. This procedure is applied to a reduced version of the interchange instability. The closure, involving the absolute value of the wave vector, is non-local in real space. In this case, the linear instability thresholds are the same, and the linear growth rates exhibit similar characteristics. Such a method is applicable to other models and classes of instabilities.

  11. Weak* sequential closures in Banach space theory and their applications

    OpenAIRE

    Ostrovskii, M. I.

    2002-01-01

    Let X be a Banach space. Given a subset A of the dual space X* denote by $A_{(1)}$ the weak* sequential closure of A, i.e., the set of all limits of weak*-convergent sequences in A. The study of weak* sequential closures of linear subspaces of the duals of separable Banach spaces was initiated by S.Banach. The first results of this study were presented in the appendix to his book "Theorie des operations lineaires" (1932). It is natural to suppose that the reason for studying weak* sequential ...

  12. Severe intravascular hemolysis after transcatheter closure of a large patent ductus arteriosus using the Amplatzer duct occluder: successful resolution by intradevice coil deployment.

    Science.gov (United States)

    Joseph, George; Mandalay, Asishkumar; Zacharias, T U; George, Biju

    2002-02-01

    A 21-year-old female developed severe unremitting intravascular hemolysis following closure of a large patent ductus arteriosus using an Amplatzer duct occluder. Percutaneous deployment of fibered platinum coils within the nitinol wire cage of the Amplatzer duct occluder abolished the residual shunt through the device and resulted in cessation of intravascular hemolysis and reversal of its adverse sequelae. Copyright 2002 Wiley-Liss, Inc.

  13. Electrophoresis device

    Science.gov (United States)

    Rhodes, P. H.; Snyder, R. S. (Inventor)

    1982-01-01

    A device for separating cellular particles of a sample substance into fractionated streams of different cellular species includes a casing having a distribution chamber, a separation chamber, and a collection chamber. The electrode chambers are separated from the separation chamber interior by means of passages such that flow variations and membrane variations around the slotted portion of the electrode chamber do not enduce flow perturbations into the laminar buffer curtain flowing in the separation chamber. The cellular particles of the sample are separated under the influence of the electrical field and the separation chamber into streams of different cellular species. The streams of separated cells enter a partition array in the collection chamber where they are fractionated and collected.

  14. Stratification devices

    DEFF Research Database (Denmark)

    Andersen, Elsa; Furbo, Simon

    2008-01-01

    heating system. High temperatures in the top of the storage tank established by the energy from the solar collector reduce the use of auxiliary energy. Low temperatures in the bottom of the storage tank improve the operation conditions for the solar collector. Using thermal stratified heat storages...... results in longer operation periods and improved utilization of the solar collector. Thermal stratification can be achieved, for example by using inlet stratification devices at all inlets to the storage tank. This paper presents how thermal stratification is established and utilized by means of inlet......Thermal stratification in the storage tank is extremely important in order to achieve high thermal performance of a solar heating system. High temperatures in the top of the storage tank and low temperatures in the bottom of the storage tank lead to the best operation conditions for any solar...

  15. Postprocedural Outcomes and Risk Factors for Arrhythmias Following Transcatheter Closure of Congenital Perimembranous Ventricular Septal Defect: A Single-center Retrospective Study

    Science.gov (United States)

    Zhao, Li-Jian; Han, Bo; Zhang, Jian-Jun; Yi, Ying-Chun; Jiang, Dian-Dong; Lyu, Jian-Li

    2017-01-01

    Background: Currently, transcatheter closure of perimembranous ventricular septal defect (pmVSD) is a widely accepted therapeutic modality. However, arrhythmias, especially postprocedural heart blocks, are a concern and outcomes are not very clear. This study explored the outcomes and risk factors of arrhythmias associated with transcatheter device closure of pmVSD. Methods: A total of 395 patients diagnosed with pmVSD who successfully underwent transcatheter intervention between January 2010 and December 2015 in our center were retrospectively reviewed. Electrocardiographic data before and after the procedure were collected and analyzed. We first evaluated the potential risk factors including gender, age, weight, inlet and outlet diameters of defect, subaortic rim length, occluder size, corrected occluder size into body surface area, fluoroscopy time, presence of aneurysm, and deployment position. We compared the potential risk factors between arrhythmia and nonarrhythmia groups using univariate analysis, followed by logistic analysis for independent risk factors. Results: Various arrhythmias were detected in 95 cases (24.1%) following transcatheter closure procedure. Logistic regression analysis revealed that eccentric (odds ratio [OR] 2.9, 95% confidence interval [CI]: 1.2–7.2) and large occluders (OR 2.0, 95% CI: 1.6–2.5), as well as long fluoroscopy time (OR 1.1, 95% CI: 1.1–1.2), were correlated with postprocedural arrhythmia. During 35.5 months (range: 9–80 months) of follow-up, most of the patients (74 out of 95) reverted to normal heart rhythm. Conclusions: The mid-term outcome of patients with arrhythmias after transcatheter closure of pmVSD was satisfactory as most of the patients recovered normal rhythm. Eccentric, large device and long fluoroscopy time increase the risk of arrhythmias after transcatheter closure of pmVSD. PMID:28229981

  16. Role of management devices in enacting strategy

    DEFF Research Database (Denmark)

    Harritz, Daniel

    2016-01-01

    the SSC’s creation. Originality/value - This study is the first to use a performative method to highlight the temporary and local nature of enacting strategic decisions to construct an SSC in the public sector. Keywords: Management control, SSC, strategic change, actor-network theory, organizational......Purpose - This study illustrates the role of management devices in enacting strategy and strategic decisions, resulting in the development of a Shared Service Centre (SSC) in a Danish municipality. It shows how devices interact in defending, rejecting and reframing strategy, leading to the closure...... of the SSC to pave the way for new strategic ideas. Design/methodology/approach - It employs a longitudinal case-based approach, which draws on actor-network theory, particularly Callon’s (1998) notions of framing and overflowing. These notions help describe strategic events and processes by highlighting...

  17. Late complete atrioventricular block after closure of an atrial septal defect with a gore septal occluder (GSO™).

    Science.gov (United States)

    Dittrich, Sven; Sigler, Matthias; Priessmann, Helga

    2016-04-01

    Temporary intermittent complete heart block (CHB) occurred the day after interventional closure of an ASD with a 30 mm Gore Septal Occluder (GSO™) in a 2 years and 11-month-old female. CHB disappeared without further treatment and stable sinus rhythm recovered within 3 days. Only short episodes of 2nd degree AV-block (Wenckebach periodicity) at rare intervals were documented in Holter-monitors the following 2 months. Eleven months after device implantation the patient suffered from long lasting episodes of CHB. Surgical removal of the device resulted in incomplete recovery of AV-conduction. Histopathological work-up of the explanted GSO showed complete endothelialization of the device and regular scar formation. One year after surgery, the child had sinus rhythm during daytime but needed VVI-pacing while sleeping. Young age, inferior localization of the defect, and use of a large device have been individual risk factors for CHB in this patient. Clinical course and histologic findings indicate that mechanical compression was the only cause for CHB. The cumulative number of reports of CHB after use of different ASD-devices supports the recommendation to postpone the intervention in asymptomatic patients to preschool-age. Early removal of a pushing device may increase the chance of complete recovery from CHB. © 2015 The Authors. Catheterization and Cardiovascular Interventions Published by Wiley Periodicals, Inc.

  18. Integrated device architectures for electrochromic devices

    Energy Technology Data Exchange (ETDEWEB)

    Frey, Jonathan Mack; Berland, Brian Spencer

    2015-04-21

    This disclosure describes systems and methods for creating monolithically integrated electrochromic devices which may be a flexible electrochromic device. Monolithic integration of thin film electrochromic devices may involve the electrical interconnection of multiple individual electrochromic devices through the creation of specific structures such as conductive pathway or insulating isolation trenches.

  19. Factors influencing ring closure through olefin metathesis - A perspective

    Indian Academy of Sciences (India)

    Subrata Ghosh; Sarita Ghosh; Niladri Sarkar

    2006-05-01

    Success of ring closure reactions of substrates having two terminal alkenes through olefin metathesis depends on a number of factors such as catalysts, nature and size of the rings to be formed and the substituents/functional groups present on the alkenes as well as at the allylic position. This article presents an overview of these influencing factors with illustrative examples.

  20. Department of Defense Base Closure and Realignment Report

    Science.gov (United States)

    1993-03-01

    Fayetteville, Arkansas Fort Smith, Arkansas Pacific Grove, California Macon, Georgia Terre Haute, Indiana Hutchinson, Kansas Monroe, Louisiana New Bedford...the body of this report. 233 Table 1. - ASE CLOSURE AND R&EALIGNMENT RECAP Bumox lam 8mmm Rqm (4m5US& M~ 10 ~MOM ed pomm ") Cbmuk APE. L Phlk Naval Hmp

  1. 12 CFR 604.430 - Closure of meetings.

    Science.gov (United States)

    2010-01-01

    ... 12 Banks and Banking 6 2010-01-01 2010-01-01 false Closure of meetings. 604.430 Section 604.430 Banks and Banking FARM CREDIT ADMINISTRATION ADMINISTRATIVE PROVISIONS FARM CREDIT ADMINISTRATION BOARD... meeting to close such meeting or such exempt portion, and the General Counsel, Farm Credit...

  2. Review on improved seismic imaging with closure phase

    KAUST Repository

    Schuster, Gerard T.

    2014-08-13

    The timing and amplitudes of arrivals recorded in seismic traces are influenced by velocity variations all along the associated raypaths. Consequently, velocity errors far from the target can lead to blurred imaging of the target body. To partly remedy this problem, we comprehensively reviewed inverting differential traveltimes that satisfied the closure-phase condition. The result is that the source and receiver statics are completely eliminated in the data and velocities far from the target do not need to be known. We successfully used the phase closure equation for traveltime tomography, refraction statics, migration, refraction tomography, and earthquake location, all of which demonstrated the higher resolution achievable by processing data with differential traveltimes rather than absolute traveltimes. More generally, the stationary version of the closure-phase equation is equivalent to Fermat’s principle and can be derived from the equations of seismic interferometry. In summary, the general closure-phase equation is the mathematical foundation for approximately redatuming sources and/or receivers to the target of interest without the need to accurately know the statics or the velocity model away from the target.

  3. REFLEX CLOSURE OF THE OESOPHAGEAL GROOVE AND ITS ...

    African Journals Online (AJOL)

    and that tIus was the main route for passage of solid matter from the rumen to ... closure of swallowing and states: "I gave milk via the. ,mouth and the .... which might suffer as a result of rumen fermentation, and some .... microbial protein produced as a result of rumen fermen- tation. .... The total lactase activity in the small in-.

  4. Planar cell polarity genes and neural tube closure.

    Science.gov (United States)

    Ueno, Naoto; Greene, Nicholas D E

    2003-11-01

    Closure of the neural tube is essential for normal development of the brain and spinal cord. Failure of closure results in neural tube defects (NTDs), common and clinically severe congenital malformations whose molecular mechanisms remain poorly understood. On the other hand, it is increasingly well established that common molecular mechanisms are employed to regulate morphogenesis of multicellular organisms. For example, signaling triggered by polypeptide growth factors is highly conserved among species and utilized in multiple developmental processes. Recent studies have revealed that the Drosophila planar cell polarity (PCP) pathway, which directs position and direction of wing hairs on the surface of the fly wing, is well conserved, and orthologs of several genes encoding components of the pathway are also found in vertebrates. Interestingly, in vertebrates, this signaling pathway appears to be co-opted to regulate "convergent extension" cell movements during gastrulation. Disruption of vertebrate PCP genes in Xenopus laevis or zebrafish causes severe gastrulation defects or the shortening of the trunk, as well as mediolateral expansion of somites. In Xenopus, in which the neural tube closes by elevation and fusion of neural folds, inhibition of convergent extension can also prevent neural tube closure causing a "spina bifida-like" appearance. Furthermore, several of the genes involved in the PCP pathway have recently been shown to be required for neural tube closure in the mouse, since mutation of these genes causes NTDs. Therefore, understanding the mechanisms underlying the establishment of cell polarity in Drosophila may provide important clues to the molecular basis of NTDs.

  5. Descending mediastinitis managed by sternotomy, taurolidine and delayed closure.

    Science.gov (United States)

    Iyer, Anand P; Kugathasan, Gana; Prabha, Ramesh; Malik, Paras; Kuteyi, Opeyemi; Larbalestier, Robert

    2013-10-01

    Descending necrotizing mediastinitis is a rare complication of upper respiratory infections. A quick diagnosis and prompt and complete surgical drainage is important for a successful outcome. A 74-year-old man with descending necrotizing mediastinitis needed a sternotomy, multiple washouts, and delayed sternal closure.

  6. Reduced heating level during the end-of-year closure

    CERN Multimedia

    2003-01-01

    To save on energy costs, the heating will once again be operating at a reduced level during the end-of-year closure of the Laboratory. We would ask all those in charge of premises where normal temperature have to be maintained to let us know by 18 December 2003 at the latest (tel. 74195 or 72201). ST/CV - ST/FM Groups

  7. REDUCED HEATING LEVEL DURING THE END-OF-YEAR CLOSURE

    CERN Multimedia

    ST/CV - ST/FM Groups

    2002-01-01

    To save on energy costs, the heating will once again be operating at a reduced level during the end-of-year closure of the Laboratory. We would ask all those in charge of premises where normal temperature have to be maintained to let us know by 19 December 2002 at the latest (tel. 74195 or 72201). ST/CV - ST/FM Groups

  8. REDUCED HEATING LEVEL DURING THE END-OF-YEAR CLOSURE

    CERN Document Server

    ST/CV - ST/TFM Groups

    2001-01-01

    To save on energy costs, the heating will once again be operating at a reduced level during the end-of-year closure of the Laboratory. We would ask all those in charge of premises where normal temperature have to be maintained to let us know by 20 December 2001 at the latest (tel.74195 or 72201).

  9. Percutaneous closure of catheter enterotomy: feasibility determination in vivo.

    Science.gov (United States)

    Roy, Sumit; Hol, Per Kristian

    2014-01-01

    To determine whether a catheter enterotomy can be percutaneously sealed with a commercially available vascular closure implant. The study was performed using a porcine model of small intestinal obstruction. Preliminary experiments were performed to allow an informed choice between two of the most promising commercially available alternatives: A multipronged metal clip (StarClose®) and a resorbable anchored polymer plate (FemoSeal®). Thereafter closure of seven enterotomies was attempted with the most suitable implant. The deployment procedure was subjectively analyzed. The sealed enterotomies were visually evaluated and hydrostatically tested. StarClose was rejected for formal assessment because it was both difficult to deploy and could not ensure a watertight seal. The conventional method for deploying FemoSeal was found to be inappropriate for percutaneously closing enterotomies. However an improvised accessory allowed all seven enterotomies to be successfully sealed with the implant using a modified procedure that involved only one additional step. After closure, six of the seven enterotomies tolerated intraluminal pressure up to 65 mm Hg. FemoSeal has the potential to serve as an implant for percutaneous closure of catheter enterotomies if the deployment tool can be appropriately modified.

  10. A Political Analysis of Community Influence over School Closure

    Science.gov (United States)

    Finnigan, Kara S.; Lavner, Mark

    2012-01-01

    This study seeks to understand community member participation in and influence over an urban school district's school closure process. Data from interviews with School Board members, district administrators, and community members, as well as district documents and newspaper articles suggest that district administrators limited participation…

  11. Interpretation and Closure in the Historical Geology Laboratory.

    Science.gov (United States)

    King, Hobart M.

    1997-01-01

    Presents an activity that convinces students that rock records do contain many types of "readable" evidence and gives students insight into the methods of historical geology. Describes a closure assignment that requires students to reflect upon what they have learned, organize their knowledge, and write a capstone essay on the history of the…

  12. Multivariate moment closure techniques for stochastic kinetic models

    Science.gov (United States)

    Lakatos, Eszter; Ale, Angelique; Kirk, Paul D. W.; Stumpf, Michael P. H.

    2015-09-01

    Stochastic effects dominate many chemical and biochemical processes. Their analysis, however, can be computationally prohibitively expensive and a range of approximation schemes have been proposed to lighten the computational burden. These, notably the increasingly popular linear noise approximation and the more general moment expansion methods, perform well for many dynamical regimes, especially linear systems. At higher levels of nonlinearity, it comes to an interplay between the nonlinearities and the stochastic dynamics, which is much harder to capture correctly by such approximations to the true stochastic processes. Moment-closure approaches promise to address this problem by capturing higher-order terms of the temporally evolving probability distribution. Here, we develop a set of multivariate moment-closures that allows us to describe the stochastic dynamics of nonlinear systems. Multivariate closure captures the way that correlations between different molecular species, induced by the reaction dynamics, interact with stochastic effects. We use multivariate Gaussian, gamma, and lognormal closure and illustrate their use in the context of two models that have proved challenging to the previous attempts at approximating stochastic dynamics: oscillations in p53 and Hes1. In addition, we consider a larger system, Erk-mediated mitogen-activated protein kinases signalling, where conventional stochastic simulation approaches incur unacceptably high computational costs.

  13. Multivariate moment closure techniques for stochastic kinetic models

    Energy Technology Data Exchange (ETDEWEB)

    Lakatos, Eszter, E-mail: e.lakatos13@imperial.ac.uk; Ale, Angelique; Kirk, Paul D. W.; Stumpf, Michael P. H., E-mail: m.stumpf@imperial.ac.uk [Department of Life Sciences, Centre for Integrative Systems Biology and Bioinformatics, Imperial College London, London SW7 2AZ (United Kingdom)

    2015-09-07

    Stochastic effects dominate many chemical and biochemical processes. Their analysis, however, can be computationally prohibitively expensive and a range of approximation schemes have been proposed to lighten the computational burden. These, notably the increasingly popular linear noise approximation and the more general moment expansion methods, perform well for many dynamical regimes, especially linear systems. At higher levels of nonlinearity, it comes to an interplay between the nonlinearities and the stochastic dynamics, which is much harder to capture correctly by such approximations to the true stochastic processes. Moment-closure approaches promise to address this problem by capturing higher-order terms of the temporally evolving probability distribution. Here, we develop a set of multivariate moment-closures that allows us to describe the stochastic dynamics of nonlinear systems. Multivariate closure captures the way that correlations between different molecular species, induced by the reaction dynamics, interact with stochastic effects. We use multivariate Gaussian, gamma, and lognormal closure and illustrate their use in the context of two models that have proved challenging to the previous attempts at approximating stochastic dynamics: oscillations in p53 and Hes1. In addition, we consider a larger system, Erk-mediated mitogen-activated protein kinases signalling, where conventional stochastic simulation approaches incur unacceptably high computational costs.

  14. Closure of open wellbores in creeping salt sheets

    NARCIS (Netherlands)

    Weijermars, R.; Jackson, M.P.A.; Van Harmelen, A.

    2013-01-01

    Safe exploration and production of pre-salt (or subsalt) hydrocarbons require that drilling operations be optimized. We introduce analytical models of wellbore closure, accounting for variations in both the wellbore net pressure and far-field flow rate of an autochthonous or allochthonous salt sheet

  15. 40 CFR 265.143 - Financial assurance for closure.

    Science.gov (United States)

    2010-07-01

    ....143 Section 265.143 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES... operator must compare the new estimate with the trustee's most recent annual valuation of the trust fund... trust agreement (see § 264.151(a)) to show current closure cost estimates; (C) Annual valuations...

  16. Uterine Closure in Cesarean Delivery: A New Technique

    Directory of Open Access Journals (Sweden)

    K M Babu

    2012-01-01

    Full Text Available Fear of scar rupture is one of risks involved in a post caesarean pregnancy. This had led to an increased rate of repeat cesarean delivery in today′s times. Closure of the uterine incision is a key step in cesarean section, and it is imperative that an optimal surgical technique be employed for closing a uterine scar. This technique should be able to withstand the stress of subsequent labor. In the existing techniques of uterine closure, single or double layer, correct approximation of the cut margins, that is, decidua-to-decidua, myometrium to myometrium, serosa to serosa is not guaranteed. Also, there are high chances of inter surgeon variability. It was felt that if a suturing technique which ensures correct approximation of all the layers mentioned above with nil or minimal possibility of inter operator variability existed, there will not be any thinning of lower segment caesarean section (LSCS. Further, a scarred uterus repaired in this manner will be able to withstand the stress of labor in future. We hereby report a new technique for uterine closure devised by us, which incorporates a continuous modified mattress suture technique as a modification of the existing surgical technique of uterine closure.

  17. Primary Closure versus Gastric Resection for Perforated Gastric ...

    African Journals Online (AJOL)

    Surgical Scales: Primary Closure versus Gastric Resection for. Perforated Gastric ... best choice? Minor or ... current practice is reserved mostly for Johnson Type I and IV ulcers .... if gastrectomy is indicated and even if the patient is fit for major ...

  18. Mechanics of epithelial closure over non-adherent environments

    Science.gov (United States)

    Vedula, Sri Ram Krishna; Peyret, Grégoire; Cheddadi, Ibrahim; Chen, Tianchi; Brugués, Agustí; Hirata, Hiroaki; Lopez-Menendez, Horacio; Toyama, Yusuke; Neves de Almeida, Luís; Trepat, Xavier; Lim, Chwee Teck; Ladoux, Benoit

    2015-01-01

    The closure of gaps within epithelia is crucial to maintain its integrity during biological processes such as wound healing and gastrulation. Depending on the distribution of extracellular matrix, gap closure occurs through assembly of multicellular actin-based contractile cables or protrusive activity of border cells into the gap. Here we show that the supracellular actomyosin contractility of cells near the gap edge exerts sufficient tension on the surrounding tissue to promote closure of non-adherent gaps. Using traction force microscopy, we observe that cell-generated forces on the substrate at the gap edge first point away from the centre of the gap and then increase in the radial direction pointing into the gap as closure proceeds. Combining with numerical simulations, we show that the increase in force relies less on localized purse-string contractility and more on large-scale remodelling of the suspended tissue around the gap. Our results provide a framework for understanding the assembly and the mechanics of cellular contractility at the tissue level.

  19. Percutaneous left atrial appendage closure for stroke prevention

    DEFF Research Database (Denmark)

    De Backer, Ole; Loupis, Anastasia M; Ihlemann, Nikolaj

    2014-01-01

    INTRODUCTION: In atrial fibrillation (AF) patients with an increased stroke risk, oral anticoagulation (OAC) is the standard treatment for stroke prevention. However, this therapy carries a high risk of major bleeding. Percutaneous closure of the left atrial appendage (LAA) is suggested as an alt......INTRODUCTION: In atrial fibrillation (AF) patients with an increased stroke risk, oral anticoagulation (OAC) is the standard treatment for stroke prevention. However, this therapy carries a high risk of major bleeding. Percutaneous closure of the left atrial appendage (LAA) is suggested...... as an alternative option for stroke prevention in AF patients with contraindication(s) for OAC treatment. MATERIAL AND METHODS: A total of 42 patients underwent percutaneous LAA closure. In this report, we describe our experience with this procedure. RESULTS: The patients treated were AF patients with a high stroke...... risk (CHADS-VASc 4.5±1.4) and contra-indication(s) for OAC and/or a high bleeding risk (HAS-BLED 3.7±0.9). A history of intracerebral bleeding was the most common reason for LAA closure. Successful implantation was obtained in 41 of 42 patients. One major peri-procedural complication occurred; a major...

  20. Fetal endoscopic myelomeningocele closure preserves segmental neurological function

    NARCIS (Netherlands)

    Verbeek, Renate J.; Heep, Axel; Maurits, Natalia M.; Cremer, Reinhold; Hoving, Eelco W.; Brouwer, Oebele F.; Van der Hoeven, Johannes H.; Sival, Deborah A.

    2012-01-01

    AIM:   Our aim was to compare the effect of prenatal endoscopic with postnatal myelomeningocele closure (fetally operated spina bifida aperta [fSBA]) versus neonatally operated spina bifida aperta [nSBA]) on segmental neurological leg condition. METHOD:   Between 2003 and 2009, the fetal surgical te