WorldWideScience

Sample records for wastewater quality control

  1. Wastewater quality control at Sarnia (Ontario, Canada) petrochemical industries

    Energy Technology Data Exchange (ETDEWEB)

    Vianna, Arlinda C. [Servico Nacional de Aprendizagem Industrial (SENAI), Salvador, BA (Brazil); Souza, Eliane S.; Himmelman, William [Lambton College, Sarnia, ON (Canada)

    1993-12-31

    Ontario industries are required by law to meet strict regulations under the provinces under MISA initiative (Municipal-Industrial Strategy for Abatement). The petroleum-petrochemical area was selected as a leader in the development of new environmental objectives, and monitoring and training programs. Sarnia has become a world leader in industrial environmental control systems and the approach toward zero emissions. 4 refs., 6 figs., 2 tabs.

  2. Wastewater quality control at Sarnia (Ontario, Canada) petrochemical industries

    Energy Technology Data Exchange (ETDEWEB)

    Vianna, Arlinda C [Servico Nacional de Aprendizagem Industrial (SENAI), Salvador, BA (Brazil); Souza, Eliane S; Himmelman, William [Lambton College, Sarnia, ON (Canada)

    1994-12-31

    Ontario industries are required by law to meet strict regulations under the provinces under MISA initiative (Municipal-Industrial Strategy for Abatement). The petroleum-petrochemical area was selected as a leader in the development of new environmental objectives, and monitoring and training programs. Sarnia has become a world leader in industrial environmental control systems and the approach toward zero emissions. 4 refs., 6 figs., 2 tabs.

  3. Application of Calibration Curve, Accuracy and Precision Chart as Internal Quality Control at COD Testing in Wastewater

    Directory of Open Access Journals (Sweden)

    Uray Lusiana

    2012-06-01

    Full Text Available Quality assurance is one of the technical requirements that include in the quality management system based on SNI ISO/IEC 17025 : 2008. Quality assurance is all the process that planned and systematic activity that applied in analysis, so can give the confidence to the customer or data user. Quality assurance that is applied for COD testing in wastewater are calibration curve, accuracy and precision control chart. The purpose of calibration curve, accuracy and precision control chart applied was to control the data of COD testing so that guaranty the validity to report and to keep the consistence of testing result as statistic all the time. Calibration curve of COD testing have a coefficient correlation 0,99987. Accuracy control chart have limited line BTA = 104,95%, BPA = 102,97%, BIA = 100,98%, BTB = 93,03%, BPB = 95,02% and BIB = 97,0%. Accuracy data can be accepted if that data present between line of BPA and BPB (± 2 SD, data is warned if that data present between line BTA-BPA or BTB-BPB (± 2 SD and ± 3 SD, and data is outlier if that data present out of line BTA and BTB (± 3 SD. The precision data can accepted if that the RPD value is not more than 10 % of COD testing result.

  4. Quality of concrete plant wastewater for reuse

    Directory of Open Access Journals (Sweden)

    H. M. Paula

    Full Text Available Efficient water use is one of the most important requirements of cleaner production, and the use of the wastewater from concrete production can be an important means to this end. However, there are no Brazilian studies on the quality of concrete plant wastewater and the activities in which such water can be used. This paper aims to evaluate the quality of concrete plant wastewater and to propose guidelines for its treatment for non-potable applications. Wastewater samples were collected from three points in the studied treatment system, and tests were later performed in the laboratory to evaluate the water quality. The results obtained were compared with the limit values for the quality parameters that have been used for the analysis of the non-potable water supply in Brazil. The results indicate a need to at least add coagulation and pH correction processes to the treatment system.

  5. Banana fertigation with treated sanitary wastewater: postharvest and microbiological quality

    Directory of Open Access Journals (Sweden)

    Pablo Fernando Santos Alves

    2017-06-01

    Full Text Available Sewage may serve as a source of water and nutrients for plants. In this study, the effects of fertigation with treated sanitary wastewater from Janaúba Sewage Treatment Plant were evaluated on the postharvest and microbiological quality of ‘Prata-Anã’ banana. A randomized block experimental design was used. Four concentrations of wastewater were tested (70, 130, 170, and 200% of 150 kg ha-1 sodium. A wastewater-free control treatment was used for comparison. Two crop cycles were assessed for postharvest and microbiological quality. The parameters measured included total soluble solids, titratable acidity, total soluble solids/titratable acidity ratio, pH, total coliforms, and fecal coliforms on both the peel and the pulp. In the first crop cycle, both soluble solids and fruit pulp pH decreased as wastewater level increased up to a maximum of 141.5%. These correlations were not observed in the second cycle. Wastewater management did not affect the titratable acidity of the soluble solids. The agricultural application of treated sanitary wastewater provided banana fruits with a microbiological profile similar to that obtained with the control (pure water and with mineral fertilizers. A microbial balance is necessary to maintain the nutritional status of the banana crop.

  6. REDUCING WASTEWATER FROM CUCUMBER PICKLING PROCESS BY CONTROLLED CULTURE FERMENTATION

    Science.gov (United States)

    On a demonstration scale, the controlled culture fermentation process (CCF) developed by the U.S. Food Fermentation Laboratory was compared with the conventional natural fermentation process (NF) in regard to product quality and yield and volume and concentration of wastewaters. ...

  7. Environmental and public health implications of wastewater quality ...

    African Journals Online (AJOL)

    The reuse of treated effluent (for agriculture and as supplement for drinking water needs) is currently receiving attention as a reliable water source. This paper is aimed at reviewing the environmental and health impacts of untreated or inadequately treated wastewater effluents. The quality of wastewater effluents is ...

  8. Nitrate control strategies in an activated sludge wastewater treatment process

    Energy Technology Data Exchange (ETDEWEB)

    Shen, Wenhao; Tao, Erpan; Chen, Xiaoquan; Liu, Dawei [South China University of Technology, Guangzhou (China); Liu, Hongbin [Kyung Hee University, Yongin (Korea, Republic of)

    2014-03-15

    We studied nitrate control strategies in an activated sludge wastewater treatment process (WWTP) based on the activated sludge model. Two control strategies, back propagation for proportional-integral-derivative (BP-PID) and adaptive-network based fuzzy inference systems (ANFIS), are applied in the WWTP. The simulation results show that the simple local constant setpoint control has poor control effects on the nitrate concentration control. However, the ANFIS (4*1) controller, which considers not only the local constant setpoint control of the nitrate concentration, but also three important indices in the effluent--ammonia concentration, total suspended sludge concentration and total nitrogen concentration--demonstrates good control performance. The results also prove that ANFIS (4*1) controller has better control performance than that of the controllers PI, BP-PID and ANFIS (2*1), and that the ANFIS (4*1) controller is effective in improving the effluent quality and maintaining the stability of the effluent quality.

  9. Changes in the physicochemical and microbial quality of wastewater ...

    African Journals Online (AJOL)

    Changes in the physicochemical and microbial quality of wastewater from a ... different points of a treatment plant and bacterial isolates were obtained from them. ... The biological oxygen demand, dissolved oxygen, pH, temperature, turbidity, ...

  10. quality control

    International Nuclear Information System (INIS)

    Skujina, A.; Purina, S.; Riekstina, D.

    1999-01-01

    The optimal objects: soils, spruce needles and bracken ferns were found for the environmental monitoring in the regions of possible radioactive contamination - near SalaspiIs nuclear reactor and Ignalina nuclear power plant. The determination of Sr-90 was based on the radiochemical separation of Sr-90 (=Y-90) by HDEHP extraction and counting the Cerenkov radiation. The quality control of the results was carried out. (authors)

  11. Sterols indicate water quality and wastewater treatment efficiency.

    Science.gov (United States)

    Reichwaldt, Elke S; Ho, Wei Y; Zhou, Wenxu; Ghadouani, Anas

    2017-01-01

    As the world's population continues to grow, water pollution is presenting one of the biggest challenges worldwide. More wastewater is being generated and the demand for clean water is increasing. To ensure the safety and health of humans and the environment, highly efficient wastewater treatment systems, and a reliable assessment of water quality and pollutants are required. The advance of holistic approaches to water quality management and the increasing use of ecological water treatment technologies, such as constructed wetlands and waste stabilisation ponds (WSPs), challenge the appropriateness of commonly used water quality indicators. Instead, additional indicators, which are direct measures of the processes involved in the stabilisation of human waste, have to be established to provide an in-depth understanding of system performance. In this study we identified the sterol composition of wastewater treated in WSPs and assessed the suitability of human sterol levels as a bioindicator of treatment efficiency of wastewater in WSPs. As treatment progressed in WSPs, the relative abundance of human faecal sterols, such as coprostanol, epicoprostanol, 24-ethylcoprostanol, and sitostanol decreased significantly and the sterol composition in wastewater changed significantly. Furthermore, sterol levels were found to be correlated with commonly used wastewater quality indicators, such as BOD, TSS and E. coli. Three of the seven sterol ratios that have previously been used to track sewage pollution in the environment, detected a faecal signal in the effluent of WSPs, however, the others were influenced by high prevalence of sterols originating from algal and fungal activities. This finding poses a concern for environmental assessment studies, because environmental pollution from waste stabilisation ponds can go unnoticed. In conclusion, faecal sterols and their ratios can be used as reliable indicators of treatment efficiency and water quality during wastewater

  12. Benchmarking of Control Strategies for Wastewater Treatment Plants

    DEFF Research Database (Denmark)

    Wastewater treatment plants are large non-linear systems subject to large perturbations in wastewater flow rate, load and composition. Nevertheless these plants have to be operated continuously, meeting stricter and stricter regulations. Many control strategies have been proposed in the literature...

  13. Environmental control technology for shale oil wastewaters

    Energy Technology Data Exchange (ETDEWEB)

    Mercer, B.W.; Wakamiya, W.; Bell, N.E.; Mason, M.J.; Spencer, R.R.; English, C.J.; Riley, R.G.

    1982-09-01

    This report summarizes the results of studies conducted at Pacific Northwest Laboratory from 1976 to 1982 on environmental control technology for shale oil wastewaters. Experimental studies conducted during the course of the program were focused largely on the treatment and disposal of retort water, particularly water produced by in situ retorting of oil shale. Alternative methods were evaluated for the treatment and disposal of retort water and minewater. Treatment and disposal processes evaluated for retort water include evaporation for separation of water from both inorganic and organic pollutants; steam stripping for ammonia and volatile organics removal; activated sludge and anaerobic digestion for removal of biodegradable organics and other oxidizable substances; carbon adsorption for removal of nonbiodegradable organics; chemical coagulation for removal of suspended matter and heavy metals; wet air oxidation and solvent extraction for removal of organics; and land disposal and underground injection for disposal of retort water. Methods for the treatment of minewater include chemical processing and ion exchange for fluoride and boron removal. Preliminary cost estimates are given for several retort water treatment processes.

  14. Wastewater Treatment for Pollution Control | Nzabuheraheza ...

    African Journals Online (AJOL)

    Performance of a Dynamic Roughing Filter (DRF) coupled with a Horizontal Subsurface Flow Constructed Wetland (HSSFCW) in the treatment of a wastewater was studied in tropical conditions. The results show that in HSSFCW planted with Cyperus papyrus and Phragmites mauritianus in series, the removal rates of TDS, ...

  15. Irrigation Water Quality Standards for Indirect Wastewater Reuse in Agriculture: A Contribution toward Sustainable Wastewater Reuse in South Korea

    Directory of Open Access Journals (Sweden)

    Hanseok Jeong

    2016-04-01

    Full Text Available Climate change and the subsequent change in agricultural conditions increase the vulnerability of agricultural water use. Wastewater reuse is a common practice around the globe and is considered as an alternative water resource in a changing agricultural environment. Due to rapid urbanization, indirect wastewater reuse, which is the type of agricultural wastewater reuse that is predominantly practiced, will increase, and this can cause issues of unplanned reuse. Therefore, water quality standards are needed for the safe and sustainable practice of indirect wastewater reuse in agriculture. In this study, irrigation water quality criteria for wastewater reuse were discussed, and the standards and guidelines of various countries and organizations were reviewed to suggest preliminary standards for indirect wastewater reuse in South Korea. The proposed standards adopted a probabilistic consideration of practicality and classified the use of irrigation water into two categories: upland and rice paddy. The standards suggest guidelines for E. coli, electric conductivity (EC, turbidity, suspended solids (SS, biochemical oxygen demand (BOD, pH, odor, and trace elements. Through proposing the standards, this study attempts to combine features of both the conservative and liberal approaches, which in turn could suggest a new and sustainable practice of agricultural wastewater reuse.

  16. Integrated control of the wastewater system – potentials and barriers

    DEFF Research Database (Denmark)

    Mollerup, Ane Loft; Grum, Morten; Muschalla, Dirk

    2013-01-01

    Applying integrated control to a sewer system and wastewater treatment plant often leads to additional benefits for both systems when compared to controlling them independently. However, barriers such as a lack of incentive for utilities to put this type of control in place mean that in practice...

  17. Wastewater treatment and pollution control in Indonesia

    International Nuclear Information System (INIS)

    Danu, Sugiarto

    2006-01-01

    Present status of radiation facilities for Co-60 gamma ray irradiation and electron beam irradiation in Indonesia is first presented. Wastewater treatment is explained: kinds of waste, industrial, agricultural, municipal and nuclear. Each liquid wastewater containing various kinds of contaminants, radioactive or non-radioactive is differently treated by waste treatment industries. On-going project is use of electron beams in which combination with ozone to reduce chlorinated solvent, disinfected sludge from sewage treatment containing organic and inorganic components for soil fertilizer, and high color river water for water supplying. The cost factor and the effect of combined treatment are being examined. Other on-going projects are applications of electron beams for vulcanization of natural rubber latex and flue gas treatment by BATAN. (S. Ohno)

  18. Online sensing and control of oil in process wastewater

    Science.gov (United States)

    Khomchenko, Irina B.; Soukhomlinoff, Alexander D.; Mitchell, T. F.; Selenow, Alexander E.

    2002-02-01

    Industrial processes, which eliminate high concentration of oil in their waste stream, find it extremely difficult to measure and control the water purification process. Most oil separation processes involve chemical separation using highly corrosive caustics, acids, surfactants, and emulsifiers. Included in the output of this chemical treatment process are highly adhesive tar-like globules, emulsified and surface oils, and other emulsified chemicals, in addition to suspended solids. The level of oil/hydrocarbons concentration in the wastewater process may fluctuate from 1 ppm to 10,000 ppm, depending upon the specifications of the industry and level of water quality control. The authors have developed a sensing technology, which provides the accuracy of scatter/absorption sensing in a contactless environment by combining these methodologies with reflective measurement. The sensitivity of the sensor may be modified by changing the fluid level control in the flow cell, allowing for a broad range of accurate measurement from 1 ppm to 10,000 ppm. Because this sensing system has been designed to work in a highly invasive environment, it can be placed close to the process source to allow for accurate real time measurement and control.

  19. Quality assessment of treated wastewater to be reused in agriculture

    Directory of Open Access Journals (Sweden)

    M.H. Rahimi

    2018-04-01

    Full Text Available In this study, the quality of a treated wastewater for agricultural and irrigation purposes was investigated. 39 quality parameters were investigated at the entrance of an effluent channel to the destination plain in monthly time intervals during a year. The aim of this study was drawing an analogy between analyses results and the latest standards in the world (nationwide and internationally, the agricultural and irrigation usage indexes and the Wilcox diagram. The results showed that some parameters such as turbidity, total suspended solids, electrical conductivity, sodium, detergents, total coliform and focal coliform, ammonium, residual sodium carbonate, the Kelly’s Ratio and the Wilcox diagram were exceeding the permissible limit and are not suitable for agriculture and irrigation. It was found that the aquifers in the study area were polluted by natural salinity and geogenic source. As a result, application of the treated wastewater from Qom for agriculture and irrigation purposes needs to be revised and monitored. An action plan is also needed to manage a huge source of water and to avoid further environmental and health risks.

  20. Assessing biodiesel quality parameters for wastewater grown Chlorella sp.

    Science.gov (United States)

    Bagul, Samadhan Yuvraj; K Bharti, Randhir; Dhar, Dolly Wattal

    2017-07-01

    Microalgae are reported as the efficient source of renewable biodiesel which should be able to meet the global demand of transport fuels. Present study is focused on assessment of wastewater grown indigenous microalga Chlorella sp. for fuel quality parameters. This was successfully grown in secondary treated waste water diluted with tap water (25% dilution) in glass house. The microalga showed a dry weight of 0.849 g L -1 with lipid content of 27.1% on dry weight basis on 21st day of incubation. After transesterification, the yield of fatty acid methyl ester was 80.64% with major fatty acids as palmitic, linoleic, oleic and linolenic. The physical parameters predicted from empirical equations in the biodiesel showed cetane number as 56.5, iodine value of 75.5 g I 2 100 g -1 , high heating value 40.1 MJ kg -1 , flash point 135 °C, kinematic viscosity 4.05 mm 2 s -1 with density of 0.86 g cm 3 and cold filter plugging point as 0.7 °C. Fourier transform infra-red (FTIR), 1 H, 13 C NMR spectrum confirmed the chemical nature of biodiesel. The results indicated that the quality of biodiesel was almost as per the criterion of ASTM standards; hence, wastewater grown Chlorella sp. can be used as a promising strain for biodiesel production.

  1. Evaluation of Water Quality Renovation by Advanced Soil-Based Wastewater Treatment Systems

    Science.gov (United States)

    Cooper, J.; Loomis, G.; Kalen, D.; Boving, T.; Morales, I.; DeLuca, J.; Amador, J.

    2013-12-01

    25% of US households utilize onsite wastewater treatment systems (OWTS) for wastewater management. Advanced technologies were designed to overcome the inadequate wastewater treatment by conventional OWTS in critical shallow water table areas, such as coastal zones, in order to protect ground water quality. In addition to the septic tank and soil drainfield that comprise a conventional OWTS, advanced systems claim improved water renovation with the addition of sand filtration, timed dosing controls, and shallow placement of the infiltrative zone. We determined water quality renovation functions under current water table and temperature conditions, in anticipation of an experiment to measure OWTS response to a climate change scenario of 30-cm increase in water table elevation and 4C temperature increase. Replicate (n=3) intact soil mesocosms were used to evaluate the effectiveness of drainfields with a conventional wastewater delivery (pipe-and-stone) compared to two types of pressurized, shallow narrow drainfield. Results under steady state conditions indicate complete removal of fecal coliform bacteria, phosphorus and BOD by all soil-based systems. By contrast, removal of total nitrogen inputs was 16% in conventional and 11% for both advanced drainfields. Effluent waters maintained a steady state pH between 3.2 - 3.7 for all technologies. Average DO readings were 2.9mg/L for conventional drainfield effluent and 4.6mg/L for advanced, showing the expected oxygen uptake with shallow placement of the infiltrative zone. The conventional OWTS is outperforming the advanced with respect to nitrogen removal, but renovating wastewater equivalently for all other contaminants of concern. The results of this study are expected to facilitate development of future OWTS regulation and planning guidelines, particularly in coastal zones and in the face of a changing climate.

  2. Qualitative and Quantitative Control of Wastewater Dual Wall Polyethylene Pipes

    Directory of Open Access Journals (Sweden)

    Mohammad Reza Salimi

    2008-09-01

    Full Text Available Pipes are the most important components of wastewater collection systems accounting for considerable costs in constructing such systems. In view of this and regarding the growing trend in design and execution of wastewater collection and transmission lines in recent years, various types of pipes have been introduced into the market. Selection of appropriate pipes and their qualitative and quantitative control, therefore, call for due consideration given their high cost share in collection systems. In this paper, efforts are made to consider various types of pipes used in (urban and rural wastewater collection networks in an attempt to signal the significance of qualitative and quantitative control of different dual wall polyethylene pipes used as sewers. Finally, the relevant issues regarding the methods and conditions for technical control and inspection of polyethylene sewer lines during construction and operation stages are provided.

  3. Quality Evaluation of Household Wastewater for Irrigation MUSA, J J ...

    African Journals Online (AJOL)

    Michael Horsfall

    waste-water discharge and disposal practices that may ... impacts from sewage contamination in urban areas are well documented ... tanks, aerated wastewater treatment systems (AWTS) ..... water sources in selected rural communities of the.

  4. Production and quality of fertirrgated cherry tomatoes with pisciculture wastewater

    Directory of Open Access Journals (Sweden)

    Thamires da Silva Araujo

    2017-07-01

    Full Text Available The aim of this work was to evaluate the production and the quality of fertirrigated cherry tomatoes with pisciculture wastewater with and without probiotics. The experiment was conducted in pots, under ambient conditions protected by 50% sombrite. The experimental design was a completely randomized design with four treatments and four replicates, the experimental unit consisting of thirty-two plants. Four water slides were tested: water; water from fish farms without the use of probiotics; water with probiotic and probiotic pisciculture wastewater. Probiotic addition was performed every 48 hours, with 0,5 g of probiotic containing at least 5x109 billion colony forming units per viable gram for every 8 L of water, each plant receiving 1 L of water manually in the morning. The soil used in the experiment to fill the vessels was classified as a NEOSOLO QUARTZARENIC dystrophic sandy texture caatinga stage, mixed with organic compound. The results showed that there was no difference between treatments for yield, number of fruits, fruit weight and pH. The treatment of water with probiotic was the one that presented lower acidity and better relation SST / ATT. The reuse of fish water with and without addition of the probiotic for fertirrigation of the cherry tomato crop did not interfere in the fruit production.

  5. Reclaimed wastewater quality enhancement by oxygen injection during transportation.

    Science.gov (United States)

    Rodríguez-Gómez, L E; Alvarez, M; Rodríguez-Sevilla, J; Marrero, M C; Hernández, A

    2011-01-01

    In-sewer treatments have been studied in sewer systems, but few have been carried out on reclaimed wastewater systems. A study of oxygen injection has been performed in a completely filled gravity pipe, 0.6 m in diameter and 62 km long, in cast iron with concrete inside coating, which is part of the reclaimed wastewater reuse scheme of Tenerife (Spain). A high pressure oxygen injection system was installed at 16.0 km from pipe inlet and a constant dosage of 30 mg/L O(2) has been injected during six months, under three different operational modes (low COD, 63 mg/L; high COD, 91 mg/L; and partially nitrified water). Oxygen has been consumed in nitrification and organic matter reduction. Generally, nitrification is clearly favored instead of the organic matter oxidation. Nitrification occurs, in general, with nitrite accumulation due to the presence of free ammonia above 1 mg/L. Denitrification is in all cases incomplete due to a limitation of easily biodegradable organic matter content, inhibiting the appearance of anaerobic conditions and sulfide generation. A notable reduction of organic matter parameters is achieved (TSS below 10 mg/L), which is significantly higher than that observed under the ordinary transport conditions without oxygen. This leads to a final cost reduction, and the oxygen injection system helps water reuse managers to maintain a final good water quality in the case of a treatment plant malfunction.

  6. A systematic methodology for controller tuning in wastewater treatment plants

    DEFF Research Database (Denmark)

    Mauricio Iglesias, Miguel; Jørgensen, S.B.; Sin, G.

    2012-01-01

    Wastewater treatment plants are typically subject to continuous disturbances caused by influent variations which exhibits diurnal patterns as well as stochastic changes due to rain and storm water events. In order to achieve an efficient operation, the control system of the plant should be able t...

  7. Identification and Control of Nutrient Removing Processes in Wastewater Treatment Plants

    DEFF Research Database (Denmark)

    Nielsen, Marinus K.; Madsen, Henrik; Carstensen, Niels Jacob

    1994-01-01

    the possibility of using statistical methods for identifying dynamical models for the biological processes. These models can then be used for simulating various control strategies and the parameters of the controllers can be found by off-line optimization. Simulation studies have shown that considerable savings......Today the use of on-line control for wastewater treatment plants is very low. A main reason is the lack of quality of the data, and the fact that more sophisticated control strategies must be based on a model of the dynamics of the biological processes. This paper discusses the historical reasons...... for the limited use of modern control strategies for wastewater treatment plants. Today, however, on-line nutrient sensors are more reliable. In the present context the use of on-line monitored values of ammonia, nitrate and phosphate from a full scale plant are used as the background for discussing...

  8. SPECT quality control tests

    International Nuclear Information System (INIS)

    Robilotta, C.C.; Rebelo, M.F.S.; Oliveira, M.A.; Abe, R.

    1987-01-01

    Quality control tests of tomographic system composed by a rotatory chamber (CGR Gammatomome T-9000) and a microcomputer are presented. Traditional quality control tests for scintilation chambers and specific tests for tomographic systems are reported. (M.A.C.) [pt

  9. Study of soil bacterial and crop quality irrigated with treated municipal wastewater

    DEFF Research Database (Denmark)

    Alinezhadian, A; Karim, A; Mohammadi, J

    2014-01-01

    Background and Objectives: In arid and semi-arid regions, wastewater reuse has become an important element in agriculture. However, irrigation with this resource can be either beneficial or harmful, depending on the wastewater characteristics. The aim of this research was to investigate the soil...... bacterial and crops quality irrigated with treated wastewater. Material and Methods: This research was conducted on a maize field near the wastewater treatment plant in Shahr-e-kord in summer,2011. Plots were arranged in a randomized complete block design in 3 replications and 2 treatments, well water (W1...

  10. Fuzzy logic for plant-wide control of biological wastewater treatment process including greenhouse gas emissions.

    Science.gov (United States)

    Santín, I; Barbu, M; Pedret, C; Vilanova, R

    2018-06-01

    The application of control strategies is increasingly used in wastewater treatment plants with the aim of improving effluent quality and reducing operating costs. Due to concerns about the progressive growth of greenhouse gas emissions (GHG), these are also currently being evaluated in wastewater treatment plants. The present article proposes a fuzzy controller for plant-wide control of the biological wastewater treatment process. Its design is based on 14 inputs and 6 outputs in order to reduce GHG emissions, nutrient concentration in the effluent and operational costs. The article explains and shows the effect of each one of the inputs and outputs of the fuzzy controller, as well as the relationship between them. Benchmark Simulation Model no 2 Gas is used for testing the proposed control strategy. The results of simulation results show that the fuzzy controller is able to reduce GHG emissions while improving, at the same time, the common criteria of effluent quality and operational costs. Copyright © 2018 ISA. Published by Elsevier Ltd. All rights reserved.

  11. Impact assessment of treated wastewater on water quality of the receiver using the Wilcoxon test

    Directory of Open Access Journals (Sweden)

    Ofman Piotr

    2017-01-01

    Full Text Available Wastewater treatment is a process which aims to reduce the concentration of pollutants in wastewater to the level allowed by current regulations. This is to protect the receivers which typically are rivers, streams, lakes. Examination of the quality of treated wastewater allows for quick elimination of possible negative effects, and the study of water receiver prevents from excessive contamination. The paper presents the results of selected physical and chemical parameters of treated wastewater from the largest on the region in north-eastern Poland city of Bialystok municipal wastewater treatment and Biała River, the receiver. The samples for research were taken 3–4 a month in 2015 from two points: before and after discharge. The impact of the wastewater treatment plant on the quality of the receiver waters was studied by using non-parametric Wilcoxon test. This test determined whether the analyzed indicators varied significantly depending on different sampling points of the river, above and below place of discharge of treated wastewater. These results prove that the treated wastewater does not affect the water quality in the Biała River.

  12. Quality assurance and quality control

    International Nuclear Information System (INIS)

    Kaden, W.

    1986-01-01

    General preconditions and methods for QA work in the nuclear field are analysed. The application of general QA principles to actual situations is illustrated by examples in the fields of engineering and of the manufacturing of mechanical and electrical components. All QA measures must be fitted to the complexity and relevance of the work steps, which are under consideration. The key to good product quality is the control of working processes. The term 'controlled process' is discussed in detail and examples of feed back systems are given. The main QA measures for the operation of nuclear power plants include the establishment of a Quality Assurance Program, training and qualification of personnel, procurement control, inspection and tests, reviews and audits. These activities are discussed. (orig.)

  13. Quality assurance and quality control

    International Nuclear Information System (INIS)

    Anon.

    1987-01-01

    The practice of nuclear diagnostic imaging requires an appropriate quality assurance program to attain high standards of efficiency and reliability. The International Atomic Energy Agency defines the term quality assurance as ''the closeness with which the outcome of a given procedure approaches some ideal, free from all errors and artifacts.'' The term quality control is used in reference to the specific measures taken to ensure that one particular aspect of the procedure is satisfactory. Therefore, quality assurance is a hospital-wide concept that should involve all aspects of clinical practice. Quality control is concerned with the submission of requests for procedures; the scheduling of patients; the preparation and dispensing of radiopharmaceuticals; the protection of patients, staff, and the general public against radiation hazards and accidents caused by radioactive materials or by faulty equipment; the setting up, use, and maintenance of electronic instruments; the methodology of the actual procedures; the analysis and interpretation of data; the reporting of results; and, finally, the keeping of records. The chapter discusses each of these areas

  14. Quality control in radiotherapy

    International Nuclear Information System (INIS)

    Batalla, A.

    2009-01-01

    The authors discuss the modalities and periodicities of internal quality control on radiotherapy installations. They indicate the different concerned systems and the aspects and items to be controlled (patient and personnel security, apparatus mechanical characteristics, beam quality, image quality, isodose and irradiation duration calculation, data transfer). They present the measurement instruments and tools used for the mechanical controls, dose measurement, beam homogeneity and symmetry, anatomic data acquisition systems, and dose distribution and control imagery calculation

  15. Quality Control Applications

    CERN Document Server

    Chorafas, Dimitris N

    2013-01-01

    Quality control is a constant priority in electrical, mechanical, aeronautical, and nuclear engineering – as well as in the vast domain of electronics, from home appliances to computers and telecommunications. Quality Control Applications provides guidance and valuable insight into quality control policies; their methods, their implementation, constant observation and associated technical audits. What has previously been a mostly mathematical topic is translated here for engineers concerned with the practical implementation of quality control. Once the fundamentals of quality control are established, Quality Control Applications goes on to develop this knowledge and explain how to apply it in the most effective way. Techniques are described and supported using relevant, real-life, case studies to provide detail and clarity for those without a mathematical background. Among the many practical examples, two case studies dramatize the importance of quality assurance: A shot-by-shot analysis of the errors made ...

  16. Software product quality control

    CERN Document Server

    Wagner, Stefan

    2013-01-01

    Quality is not a fixed or universal property of software; it depends on the context and goals of its stakeholders. Hence, when you want to develop a high-quality software system, the first step must be a clear and precise specification of quality. Yet even if you get it right and complete, you can be sure that it will become invalid over time. So the only solution is continuous quality control: the steady and explicit evaluation of a product's properties with respect to its updated quality goals.This book guides you in setting up and running continuous quality control in your environment. Star

  17. Advanced monitoring of wastewater quality: data collection and data quality assurance

    DEFF Research Database (Denmark)

    Alferes, Janelcy; Lamaire-Chad, C.; Chhetri, Ravi Kumar

    and in evaluating the impact of discharges on the receiving water bodies. As measurements are carried out under arduous conditions, practical implementation of such monitoring systems entails several challenges, and automation of data collection and data quality assessment has been recognised as a critical issue....... In this paper, a data quality assessment strategy is presented to achieve efficient water quality monitoring in real-world scenarios. Next to practical aspects concerning installation and maintenance of sensors, the paper also presents a software tool aimed at assessing the quality of the data being collected....... In this paper, results showed the successful implementation of the proposed strategy for collection of water quality data at the inlet of a wastewater treatment plant....

  18. Control and decision strategies in wastewater treatment plants for operation improvement

    CERN Document Server

    Santín, Ignacio; Vilanova, Ramón

    2017-01-01

    This book examines the operation of biological wastewater treatment plants (WWTPs), with a focus on maintaining effluent water quality while keeping operational costs within constrained limits. It includes control operation and decision schemes and is based on the use of benchmarking scenarios that yield easily reproducible results that readers can implement for their own solutions. The final criterion is the effect of the applied control strategy on plant performance – specifically, improving effluent quality, reducing costs and avoiding violations of established effluent limits. The evaluation of the different control strategies is achieved with the help of two Benchmark Simulation Models (BSM1, BSM2). Given the complexity of the biological and biochemical processes involved and the major fluctuations in the influent flow rate, controlling WWTPs poses a serious challenge. Further, the importance of control goal formulation and control structure design in relation to WWTP process control is widely recogniz...

  19. Removal of COD and turbidity to improve wastewater quality using electrocoagulation technique

    International Nuclear Information System (INIS)

    Mohd Faiqun Niam; Fadil Othman; Johan Sohaili; Zulfa Fauzia

    2007-01-01

    Electrocoagulation (EC) is becoming a popular process to be used for wastewater treatment. The removal of COD and turbidity from wastewater by EC using iron (Fe) electrode material was investigated in this paper. Several working parameters, such as pH, current density, and operating time were studied in an attempt to achieve a higher removal capacity. Wastewater sample was made from milk powder with initial COD of 1140 mgL -1 and turbidity of 491 NTU. Current density was varied from 3.51 to 5.62 mA cm -2 , and operating time of between 30 and 50 minutes. The results show that the effluent wastewater was very clear and its quality exceeded the direct discharge standard. The removal efficiencies of COD and turbidity were high, being more than 65 % and 95 %. In addition, the experimental results also show that the electrocoagulation can neutralize pH of wastewater. (author)

  20. Environmental and public health implications of wastewater quality

    African Journals Online (AJOL)

    user

    2011-03-28

    Mar 28, 2011 ... metals are one of the most persistent pollutants in waste- water. Unlike organic ... nitrate levels that affect infants do not pose a direct threat to older children ...... Rybicki S (1997). Advanced Wastewater Treatment: Phosphorus.

  1. Checking quality control?

    DEFF Research Database (Denmark)

    Brodersen, Lars

    2005-01-01

    How is quality control doing within the community of GIS, web-services based on geo-information, GI etc.?......How is quality control doing within the community of GIS, web-services based on geo-information, GI etc.?...

  2. The supply and demand for pollution control: Evidence from wastewater treatment

    Science.gov (United States)

    McConnell, V.D.; Schwarz, G.E.

    1992-01-01

    This paper analyzes the determination of pollution control from wastewater treatment plants as an economic decision facing local or regional regulators. Pollution control is measured by plant design effluent concentration levels and is fully endogenous in a supply- and-demand model of treatment choice. On the supply side, plant costs are a function of the design treatment level of the plant, and on the demand side, treatment level is a function of both the costs of control and the regional or regulatory preferences for control. We find evidence that the economic model of effluent choice by local regulators has a good deal of explanatory power. We find evidence that wastewater treatment plant removal of biological oxygen demand (BOD) is sensitive to many local factors including the size of the treatment plant, the flow rate of the receiving water, the population density of the surrounding area, regional growth, state sensitivity to environmental issues, state income, and the extent to which the damages from pollution fall on other states. We find strong evidence that regulators are sensitive to capital costs in determining the design level of BOD effluent reduction at a plant. Thus, proposed reductions in federal subsidies for wastewater treatment plant construction are likely to have significant adverse effects on water quality. ?? 1992.

  3. Nonlinear PI Control with Adaptive Interaction Algorithm for Multivariable Wastewater Treatment Process

    Directory of Open Access Journals (Sweden)

    S. I. Samsudin

    2014-01-01

    Full Text Available The wastewater treatment plant (WWTP is highly known with the nonlinearity of the control parameters, thus it is difficult to be controlled. In this paper, the enhancement of nonlinear PI controller (ENon-PI to compensate the nonlinearity of the activated sludge WWTP is proposed. The ENon-PI controller is designed by cascading a sector-bounded nonlinear gain to linear PI controller. The rate variation of the nonlinear gain kn is automatically updated based on adaptive interaction algorithm. Initiative to simplify the ENon-PI control structure by adapting kn has been proved by significant improvement under various dynamic influents. More than 30% of integral square error and 14% of integral absolute error are reduced compared to benchmark PI for DO control and nitrate in nitrogen removal control. Better average effluent qualities, less number of effluent violations, and lower aeration energy consumption resulted.

  4. Quality control of radiopharmaceuticals

    International Nuclear Information System (INIS)

    Verdera, E.S.

    1994-01-01

    The quality control of radiopharmaceuticals is based in physics, physics-chemical and biological controls. Between the different controls can be enumerated the following: visual aspect,side, number of particle beams,activity,purity,ph,isotonicity,sterility,radioinmunoessay,toxicity,stability and clinical essay

  5. Quality Control in construction.

    Science.gov (United States)

    1984-01-01

    behavioral scientists. In 1962, Dr. Kaoru Ishikawa gave shape to the form of training which featured intradepartmental groups of ten or so workers seated...and Japanese circles bears closer scrutiny. 4.3.1 Japanese Ingredients of Quality The founder of quality circles, Dr. Kaoru Ishikawa , gives six...around 51 a table; hence the name Quality Control Circle. 4 Dr. 0 Ishikawa was an engineering professor at Tokyo University, and the circles were

  6. Operation and effluent quality of a small rural wastewater treatment ...

    African Journals Online (AJOL)

    The objective of this study was to evaluate the impact of effluent and sludge discharges of an abattoir wastewater treatment plant (WWTP) on the operation of a municipal aerated pond WWTP. Experiments were carried out in Cervera WWTP, located in northeastern Spain, which comprises four ponds operating in series.

  7. Quality Evaluation of Household Wastewater for Irrigation | Musa ...

    African Journals Online (AJOL)

    Ten samples were collected respectively from kitchen, laundry and toilet wastewaters were collected and physical, chemical, metallic and non-metallic analysis were carried out on the various samples collected following standard procedures. @JASEM J. Appl. Sci. Environ. Manage. Sept, 2011, Vol. 15 (3) 431 - 437 ...

  8. Combination of electrochemical processes with membrane bioreactors for wastewater treatment and fouling control: A review

    Directory of Open Access Journals (Sweden)

    Benny Marie B. Ensano

    2016-08-01

    Full Text Available This paper provides a critical review about the integration of electrochemical processes into membrane bioreactors (MBR in order to understand the influence of these processes on wastewater treatment performance and membrane fouling control. The integration can be realized either in an internal or an external configuration. Electrically enhanced membrane bioreactors or electro membrane bioreactors (eMBRs combine biodegradation, electrochemical and membrane filtration processes into one system providing higher effluent quality as compared to conventional MBRs and activated sludge plants. Furthermore, electrochemical processes, such as electrocoagulation, electrophoresis and electroosmosis, help to mitigate deposition of foulants into the membrane and enhance sludge dewaterability by controlling the morphological properties and mobility of the colloidal particles and bulk liquid. Intermittent application of minute electric field has proven to reduce energy consumption and operational cost as well as minimize the negative effect of direct current field on microbial activity which are some of the main concerns in eMBR technology. The present review discusses important design considerations of eMBR, its advantages as well as its applications to different types of wastewater. It also presents several challenges that need to be addressed for future development of this hybrid technology which include treatment of high strength industrial wastewater and removal of emerging contaminants, optimization study, cost benefit analysis and the possible combination with microbial electrolysis cell for biohydrogen production.

  9. Impact on enzyme activity as a new quality index of wastewater.

    Science.gov (United States)

    Balestri, Francesco; Moschini, Roberta; Cappiello, Mario; Del-Corso, Antonella; Mura, Umberto

    2013-03-15

    The aim of this study was to define a new indicator for the quality of wastewaters that are released into the environment. A quality index is proposed for wastewater samples in terms of the inertness of wastewater samples toward enzyme activity. This involves taking advantage of the sensitivity of enzymes to pollutants that may be present in the waste samples. The effect of wastewater samples on the rate of a number of different enzyme-catalyzed reactions was measured, and the results for all the selected enzymes were analyzed in an integrated fashion (multi-enzymatic sensor). This approach enabled us to define an overall quality index, the "Impact on Enzyme Function" (IEF-index), which is composed of three indicators: i) the Synoptic parameter, related to the average effect of the waste sample on each component of the enzymatic sensor; ii) the Peak parameter, related to the maximum effect observed among all the effects exerted by the sample on the sensor components; and, iii) the Interference parameter, related to the number of sensor components that are affected less than a fixed threshold value. A number of water based samples including public potable tap water, fluids from urban sewage systems, wastewater disposal from leather, paper and dye industries were analyzed and the IEF-index was then determined. Although the IEF-index cannot discriminate between different types of wastewater samples, it could be a useful parameter in monitoring the improvement of the quality of a specific sample. However, by analyzing an adequate number of waste samples of the same type, even from different local contexts, the profile of the impact of each component of the multi-enzymatic sensor could be typical for specific types of waste. The IEF-index is proposed as a supplementary qualification score for wastewaters, in addition to the certification of the waste's conformity to legal requirements. Copyright © 2013 Elsevier Ltd. All rights reserved.

  10. The Use of Irradiation Technology in Improving Water and Wastewater Quality

    International Nuclear Information System (INIS)

    Amro, H.; Tuffaha, R.; Zinati, S.; Juneidi, M.; Masaadeh, M.

    2004-01-01

    A study was undertaken to examine the use of irradiation technology in improving the water quality. A Cobalt- 60 gamma radiation source was used in studying the removal of trihalo methane (THM) compounds from drinking water, which forms as a result of using chlorine for water disinfection. The study also includes the use of irradiation processing for water disinfection as a substitute of water chlorination. The results show that a dose of 1000 Gy is efficient in removing 100 μg/l of THM compounds from drinking water. The same dose is also found efficient for disinfecting and controlling the microbiological content of contaminated surface water. The highly contaminated raw municipal wastewater found to require a radiation dose in the range of 1000 to 5000 Gy. (authors)

  11. Operating household wastewater treatment plants in the light of binding quality standards for wastewater discharged to water bodies or to soil

    Directory of Open Access Journals (Sweden)

    Jawecki Bartosz

    2017-03-01

    Full Text Available The study presents the legal requirements concerning the quality of wastewater discharged to waterbodies and to soil after treatment in household wastewater treatment plants located in agglomerations or outside them. The procedure of stopping the operation of a household treatment plant that doesn’t meet the statutory wastewater treatment efficiency was presented. The decision ordering to stop the use of a household wastewater treatment plant has to be preceded by a decision ordering to take measures to limit its adverse impact on the environment. The clarification procedure has to determine the adverse impact on the environment in a doubtless manner and it has to be reflected in the documentation. The assessment of adverse impact should take into account the binding standards of use of the environment. Stopping the operation of a household wastewater treatment plant may result in issuing a decision ordering the user to connect to the sanitary sewage system.

  12. Quality control of radiopharmaceuticals

    International Nuclear Information System (INIS)

    Kristensen, K.

    1981-01-01

    Quality assurance was introduced in the pharmaceutical field long before it was used in many other areas, and the term quality control has been used in a much broader sense than merely analytical quality control. The term Good Manufacturing Practice (GMP) has been used to describe the system used for producing safe and effective drugs of a uniform quality. GMP has also been used for the industrial production of radiopharmaceuticals. For the preparation and control of radiopharmaceuticals in hospitals a similar system has been named Good Radiopharmacy Practice (GRP). It contains the same elements as GMP but takes into account the special nature of this group of drugs. Data on the assessment of the quality of radiopharmaceuticals in relation to present standards are reviewed. The general conclusion is that the quality of radiopharmaceuticals appears comparable to that of other drugs. It seems possible to establish the production of radiopharmaceuticals, generators and preparation kits in such a way that analytical control of the final product at the hospital may be limited provided the final preparation work is carried out in accordance with GRP principles. The elements of GRP are reviewed. (author)

  13. Quality control of dosemeters

    International Nuclear Information System (INIS)

    Mendes, L.

    1984-01-01

    Nuclear medicine laboratories are required to assay samples of radioactivity to be administered to patients. Almost universally, these assays are acomplished by use of a well ionization chamber isotope calibrator. The Instituto de Radioprotecao e Dosimetria (Institute for Radiological Protection and Dosimetry) of the Comissao Nacional de Energia Nuclear (National Commission for Nuclear Energy) is carrying out a National Quality Control Programme in Nuclear Medicine, supported by the International Atomic Energy Agency. The assessment of the current needs and practices of quality control in the entire country of Brazil includes Dose Calibrators and Scintilation Cameras, but this manual is restricted to the former. Quality Control Procedures for these Instruments are described in this document together with specific recommendations and assessment of its accuracy. (Author) [pt

  14. Quality Management, Quality Assurance and Quality Control in Blood Establishments

    OpenAIRE

    Bolbate, N

    2008-01-01

    Quality terms and the roots of the matter are analyzed according to European Committee’s recommendations. Essence of process and product quality control as well as essence of quality assurance is described. Quality system’s structure including quality control, quality assurance and management is justified in the article.

  15. Multi-objective optimisation of wastewater treatment plant control to reduce greenhouse gas emissions.

    Science.gov (United States)

    Sweetapple, Christine; Fu, Guangtao; Butler, David

    2014-05-15

    This study investigates the potential of control strategy optimisation for the reduction of operational greenhouse gas emissions from wastewater treatment in a cost-effective manner, and demonstrates that significant improvements can be realised. A multi-objective evolutionary algorithm, NSGA-II, is used to derive sets of Pareto optimal operational and control parameter values for an activated sludge wastewater treatment plant, with objectives including minimisation of greenhouse gas emissions, operational costs and effluent pollutant concentrations, subject to legislative compliance. Different problem formulations are explored, to identify the most effective approach to emissions reduction, and the sets of optimal solutions enable identification of trade-offs between conflicting objectives. It is found that multi-objective optimisation can facilitate a significant reduction in greenhouse gas emissions without the need for plant redesign or modification of the control strategy layout, but there are trade-offs to consider: most importantly, if operational costs are not to be increased, reduction of greenhouse gas emissions is likely to incur an increase in effluent ammonia and total nitrogen concentrations. Design of control strategies for a high effluent quality and low costs alone is likely to result in an inadvertent increase in greenhouse gas emissions, so it is of key importance that effects on emissions are considered in control strategy development and optimisation. Copyright © 2014 Elsevier Ltd. All rights reserved.

  16. The assessment of treated wastewater quality and the effects of mid-term irrigation on soil physical and chemical properties (case study: Bandargaz-treated wastewater)

    Science.gov (United States)

    Kaboosi, Kami

    2017-09-01

    This study was conducted to investigate the characteristics of inflow and outflow wastewater of the Bandargaz wastewater treatment plant on the basis of the data collection of operation period and the samples taken during the study. Also the effects of mid-term use of the wastewater for irrigation (from 2005 to 2013) on soil physical and chemical characteristics were studied. For this purpose, 4 samples were taken from the inflow and outflow wastewater and 25 quality parameters were measured. Also, the four soil samples from a depth of 0-30 cm of two rice field irrigated with wastewater in the beginning and middle of the planting season and two samples from one adjacent rice field irrigated with fresh water were collected and their chemical and physical characteristics were determined. Average of electrical conductivity, total dissolved solids, sodium adsorption ratio, chemical oxygen demand and 5 days biochemical oxygen demand in treated wastewater were 1.35 dS/m, 707 ppm, 0.93, 80 ppm and 40 ppm, respectively. Results showed that although some restrictions exist about chlorine and bicarbonate, the treated wastewater is suitable for irrigation based on national and international standards and criteria. In comparison with fresh water, the mid-term use of wastewater caused a little increase of soil salinity. However, it did not lead to increase of soil salinity beyond rice salinity threshold. Also, there were no restrictions on soil in the aspect of salinity and sodium hazard on the basis of many irrigated soil classifications. In comparison with fresh water, the mid-term use of wastewater caused the increase of total N, absorbable P and absorbable K in soil due to high concentration of those elements in treated wastewater.

  17. Quality control in haemostasis.

    Science.gov (United States)

    Capel, P; Chatelain, B; Leclerq, R; Lust, A; Masure, R; Arnout, J

    1992-01-01

    Laboratory investigation of the haemostatic system deserves particular procedures in the quality control of analytical variables as well as preanalytical variables. This paper reviews the precautions that have to be taken in the blood prelevement, the transport of the tubes and the performance of the laboratory tests aimed to investigate the haemostatic system in order to obtain reliable results.

  18. Ocean Data Quality Control

    Science.gov (United States)

    2011-11-18

    the aero- sol at the coincident time and location of the satellite SST retrievals. This informa- tion is available in the daytime for the anti-solar...are of the same form, such as probabilities or standard normal deviates. A quality control decision-making algorithm in use at the U.S. Navy oceano

  19. Evaluation of polar organic micropollutants as indicators for wastewater-related coastal water quality impairment

    International Nuclear Information System (INIS)

    Nödler, Karsten; Tsakiri, Maria; Aloupi, Maria; Gatidou, Georgia; Stasinakis, Athanasios S.; Licha, Tobias

    2016-01-01

    Results from coastal water pollution monitoring (Lesvos Island, Greece) are presented. In total, 53 samples were analyzed for 58 polar organic micropollutants such as selected herbicides, biocides, corrosion inhibitors, stimulants, artificial sweeteners, and pharmaceuticals. Main focus is the application of a proposed wastewater indicator quartet (acesulfame, caffeine, valsartan, and valsartan acid) to detect point sources and contamination hot-spots with untreated and treated wastewater. The derived conclusions are compared with the state of knowledge regarding local land use and infrastructure. The artificial sweetener acesulfame and the stimulant caffeine were used as indicators for treated and untreated wastewater, respectively. In case of a contamination with untreated wastewater the concentration ratio of the antihypertensive valsartan and its transformation product valsartan acid was used to further refine the estimation of the residence time of the contamination. The median/maximum concentrations of acesulfame and caffeine were 5.3/178 ng L"−"1 and 6.1/522 ng L"−"1, respectively. Their detection frequency was 100%. Highest concentrations were detected within the urban area of the capital of the island (Mytilene). The indicator quartet in the gulfs of Gera and Kalloni (two semi-enclosed embayments on the island) demonstrated different concentration patterns. A comparatively higher proportion of untreated wastewater was detected in the gulf of Gera, which is in agreement with data on the wastewater infrastructure. The indicator quality of the micropollutants to detect wastewater was compared with electrical conductivity (EC) data. Due to their anthropogenic nature and low detection limits, the micropollutants are superior to EC regarding both sensitivity and selectivity. The concentrations of atrazine, diuron, and isoproturon did not exceed the annual average of their environmental quality standards (EQS) defined by the European Commission. At two

  20. VGI QUALITY CONTROL

    Directory of Open Access Journals (Sweden)

    C. C. Fonte

    2015-08-01

    Full Text Available This paper presents a framework for considering quality control of volunteered geographic information (VGI. Different issues need to be considered during the conception, acquisition and post-acquisition phases of VGI creation. This includes items such as collecting metadata on the volunteer, providing suitable training, giving corrective feedback during the mapping process and use of control data, among others. Two examples of VGI data collection are then considered with respect to this quality control framework, i.e. VGI data collection by National Mapping Agencies and by the most recent Geo-Wiki tool, a game called Cropland Capture. Although good practices are beginning to emerge, there is still the need for the development and sharing of best practice, especially if VGI is to be integrated with authoritative map products or used for calibration and/or validation of land cover in the future.

  1. Quality control of mammography

    International Nuclear Information System (INIS)

    Hering, K.G.

    1986-01-01

    Random checks of mammograms allow to clearly assess quality controls concerning correct application and operation of the radiographic system indicated by rich contrast in breast tissue images, complete imaging of the mammary parenchyma, freedom from blurs due to motion, efficient breast compression, correct film labelling and perfect maintenance of the film screen system. In addition to these subjective assessments, the following points should be considered when using objective measurement procedures and phantoms: Testing the correct function of X-ray and radiographic equipment by means of test specimens to measure KV standard (KV=Association of German Panel Doctors), mAS and automatic exposure timer; comparing dose and density to initial values and checking film processing by using a sensitometer. Quality assurance handling varies from one KV to the next. That is why the users need to obtain the guidelines of the respective KV relative to radiological quality assurance and to proceed according to these. (orig.) [de

  2. Seasonal changes in quality of wastewater from fruit and vegetable industry

    Science.gov (United States)

    Puchlik, Monika; Ignatowicz, Katarzyna

    2017-11-01

    The paper aimed at evaluating the seasonal changes in quality of wastewater from facilities producing fruit and vegetable juices, processed and frozen products, and vegetable concentrates. The study revealed that wastewater from fruit and vegetable industry contain large amounts of organic substances expressed as BOD5 (minimum - 500 mgO2/dm3, maximum - 6 100 mgO2/dm3) and COD (minimum - 806 mg O2/dm3, maximum - 7 732 mg O2/dm3), while is deficient in nitrogen and phosphorus. Considerable seasonal oscillations in sewage load disposed by industry to sewerage, were observed. An increase of 50%-60% wastewater concentrations was found between June and October in 2013-2016 as compared to the remaining months.

  3. Influence of wastewater reuse on the microbiological quality of sunflowers for animal feed

    Directory of Open Access Journals (Sweden)

    Roseanne Santos de Carvalho

    2013-08-01

    Full Text Available The use of treated wastewater for agricultural purposes can be an alternative to maintaining the quality of water bodies and the biota of natural systems. It can also reduce the demand for water and preserve water supplies for more important uses. This study aimed to evaluate the effects of wastewater reuse in the microbiological quality of above ground parts of sunflower crops. The experiment was conducted from July to September 2012 in the greenhouse of the Department of Agricultural Engineering (DEA at the Federal University of Sergipe, São Cristóvão Campus. Treated wastewater was collected at the Sewage Treatment Plant (WWTP Rosa Elze, located in the municipality of São Cristóvão, SE. Irrigation was performed using different ratios of water and treated wastewater. The irrigation followed the FAO 56 method. We used a completely randomized design (CRD with five treatments and four replicates per plot. The data were analyzed according to the parameters recommended by Resolution no. 12, 02/01/2001 of the Brazilian National Agency for Sanitary Vigilance. Coliforms, E. coli, yeast and mold, and Salmonella were counted. Results have shown that the microbiological quality of the superficial area of sunflower crops analyzed met the standards of Brazilian law. However, further studies should be conducted to investigate the effects of soil.

  4. Quality control of intelligence research

    International Nuclear Information System (INIS)

    Lu Yan; Xin Pingping; Wu Jian

    2014-01-01

    Quality control of intelligence research is the core issue of intelligence management, is a problem in study of information science This paper focuses on the performance of intelligence to explain the significance of intelligence research quality control. In summing up the results of the study on the basis of the analysis, discusses quality control methods in intelligence research, introduces the experience of foreign intelligence research quality control, proposes some recommendations to improve quality control in intelligence research. (authors)

  5. The effect of reclaimed wastewater on the quality and growth of grapevines.

    Science.gov (United States)

    Mendoza-Espinosa, L G; Cabello-Pasini, A; Macias-Carranza, V; Daessle-Heuser, W; Orozco-Borbón, M V; Quintanilla-Montoya, A L

    2008-01-01

    The effect of the use of treated wastewater on the growth of cabernet sauvignon and merlot grapes from the Guadalupe Valley, Mexico was evaluated. Secondary advanced effluent was used to irrigate the grapevines at a rate of 66 L/vine/week. Wastewater quality results confirmed that all parameters complied with Mexican legislation for crop irrigation as well as reuse in activities in which the public would be in direct or indirect contact with the reclaimed water. Results showed that the number of leaves per shoot and the overall biomass increased in plants irrigated with wastewater and grape production per plant was 20% higher. The concentration of carbohydrates, organic acids and pH were similar in grapes from vines irrigated with wastewater to those irrigated with groundwater. Throughout the experiment, no fecal coliform bacteria were detected in the cultivated grapes. The wastewater caused an increase in the biomass of the grapevines and there was no presence of microbial indicators in the final product so a higher wine production could be achieved without an increase in health risk related problems. If 200 L/s of reclaimed wastewater would be returned to be used for grapevine irrigation in Valle de Guadalupe (the same amount that is currently being sent as drinking water to Ensenada), assuming an irrigation application of 6,000-7.500 m3/ha/year, approximately 837-1046 hectares (ha) of grapevines could be irrigated. Part of ongoing research includes an economical analysis of the best options for Ensenada and the Valle de Guadalupe in order to establish the optimum volume of water to be returned, the cost of its transportation, as well as the cost of irrigation. (c) IWA Publishing 2008.

  6. The influence of the microbial quality of wastewater, lettuce cultivars and enumeration technique when estimating the microbial contamination of wastewater-irrigated lettuce.

    Science.gov (United States)

    Makkaew, P; Miller, M; Cromar, N J; Fallowfield, H J

    2017-04-01

    This study investigated the volume of wastewater retained on the surface of three different varieties of lettuce, Iceberg, Cos, and Oak leaf, following submersion in wastewater of different microbial qualities (10, 10 2 , 10 3 , and 10 4 E. coli MPN/100 mL) as a surrogate method for estimation of contamination of spray-irrigated lettuce. Uniquely, Escherichia coli was enumerated, after submersion, on both the outer and inner leaves and in a composite sample of lettuce. E. coli were enumerated using two techniques. Firstly, from samples of leaves - the direct method. Secondly, using an indirect method, where the E. coli concentrations were estimated from the volume of wastewater retained by the lettuce and the E. coli concentration of the wastewater. The results showed that different varieties of lettuce retained significantly different volumes of wastewater (p 0.01) were detected between E. coli counts obtained from different parts of lettuce, nor between the direct and indirect enumeration methods. Statistically significant linear relationships were derived relating the E. coli concentration of the wastewater in which the lettuces were submerged to the subsequent E. coli count on each variety the lettuce.

  7. Effects of bleaching wastewater irrigation on soil quality of constructed reed wetlands

    Directory of Open Access Journals (Sweden)

    Cheng Ding

    2016-10-01

    Full Text Available Constructed reed wetland microcosms (CRWs in a lab of east China have been irrigated with bleaching wastewater per month for a reed growth season. The soil physicochemical properties, enzyme activities (i.e. urease, invertase, polyphenol oxidase, alkaline phosphatase and cellulase and soil microbial diversity were assayed before and after the exposure experiment. Compared to the river water irrigated controls (CKs, bleaching wastewater application has no marked influence on soil pH, but significantly increased soil Na+, total halogen and absorbable organic halogen (AOX contents, which induced the increasing of soil electrical conductivity. Furthermore, soil enzyme activities displayed significant variation (except for polyphenol oxidase. Bleaching wastewater irrigation decreased Sorenson’s pairwise similarity coefficient (Cs, which indicated the changes of the structure of bacterial and fungal communities. However, only the diversity of bacterial community was inhibited and has no effect on the diversity of fungal community, as evidenced by the calculated Shannon–Wiener index (H.

  8. A hybrid artificial neural network as a software sensor for optimal control of a wastewater treatment process.

    Science.gov (United States)

    Choi, D J; Park, H

    2001-11-01

    For control and automation of biological treatment processes, lack of reliable on-line sensors to measure water quality parameters is one of the most important problems to overcome. Many parameters cannot be measured directly with on-line sensors. The accuracy of existing hardware sensors is also not sufficient and maintenance problems such as electrode fouling often cause trouble. This paper deals with the development of software sensor techniques that estimate the target water quality parameter from other parameters using the correlation between water quality parameters. We focus our attention on the preprocessing of noisy data and the selection of the best model feasible to the situation. Problems of existing approaches are also discussed. We propose a hybrid neural network as a software sensor inferring wastewater quality parameter. Multivariate regression, artificial neural networks (ANN), and a hybrid technique that combines principal component analysis as a preprocessing stage are applied to data from industrial wastewater processes. The hybrid ANN technique shows an enhancement of prediction capability and reduces the overfitting problem of neural networks. The result shows that the hybrid ANN technique can be used to extract information from noisy data and to describe the nonlinearity of complex wastewater treatment processes.

  9. Organizing quality control programmes

    International Nuclear Information System (INIS)

    Hjardemaal, O.

    1989-01-01

    When procuring new equipment, performance and safety should be specified, if possible by reference to international standards. Some of the characteristics of the International Electrotechnical Commission (IEC) standard for X-ray generators, in particular the accuracy of the operating data, are described. The quality control tests to be performed after installation comprise acceptance test, status test and constancy test. The first two involve absolute measurements and will be the responsibility of physicists or engineers. Apparently limiting values stipulated by users are a factor of two lower than the limits of the IEC standard. By means of an example it is shown that modern X-ray generators can meet the lower limits of the users without problems. In order to obtain optimum initial quality when procuring new equipment operating data, limiting values must be specified and must be verified by acceptance testing, etc. However, in many countries physicists and engineers are not available for this job. A relatively uncomplicated test object can be used by radiographers for checks on fluoroscopic systems. The findings from such tests in Denmark are compared with other published findings and good agreement is found. Therefore it is proposed that such uncomplicated tests could form the basis for quality evaluation. (author)

  10. EVALUATION OF LEATHER QUALITY AND ECOTOXICITY IN SIMULATED TANNERY WASTEWATERS USING MIMOSA TANNIN

    Directory of Open Access Journals (Sweden)

    ÇELİK Cem

    2016-05-01

    Full Text Available The leather tanning industry is characterized by the production of different kinds of effluents, generated in each step of leather processing. These effluents have various chemical compounds which may cause toxicity and endocrine disruption and are thus known as endocrine disrupting chemicals (EDC. Tanning stabilizes the protein structure of the hide and imparts heat stability, enhanced tensile properties, and resistance to microbial degradation. Currently most high quality leather is "chrome-tanned," produced by treatment of the hide with salts of the mineral chromium. In this study, the wastewater characteristics and ecotoxicity before and after tanning and retanning processes using mimosa tannin are assessed. Vegetable leather production procedure was followed using one dose mimosa tannin. Leather quality was evaluated according to standard methods. Wastewater characteristics showed that mimosa contributed high organic content to the wastewater. Although vegetable tannin was used the effluent toxicity was observed in tanning and retanning effluents. The preliminary results also showed that leather quality tests failed or at minimum level to comply with the standard values indicating that there is still a need to optimize the procedure including mimosa dose. This study was designed to produce eco-friendly leather using mimosa in tanning and retanning processes. Leather quality and the ecotoxicity of each process during leather production was assessed according to standard methods.

  11. Quality control of radiodiagnostics

    International Nuclear Information System (INIS)

    Alonso Diaz, M.; Castaneda Arronte, M.J.; Matorras Galan, P.; Diaz-Caneja Rodriguez, N.; Gutierrez Diaz Velarde, I.

    1993-01-01

    Since May 1990, a program of quality control of diagnostic X-ray equipment is underway in the University Hospital Marques de Valdecilla. This includes the design and application of measuring specifications and procedures corresponding to the different parameters of the equipment. The specified values are presented, as are those obtained for geometric and exposition parameters using the equipment. The specifications for the geometric parameters are fulfilled in an large proportion (between 52 and 86%) of the units, and the rest can easily be adjusted. However, 85% of the units can be made to operate with a field larger than that of the screen of the image monitor and approximately half of them can operate at a shorter focus-to-patient distance than that specified. With respect to the exposition parameters, in general, these units do not fulfill the specifications and their behavior is not uniform. The results obtained indicate that the equipment studied could be made to comply with the proposed specifications if a Maintenance Program were initiated in coordination with that of Quality Control. (Author)

  12. Assessment of ground water quality in a fractured aquifer under continue wastewater injection

    International Nuclear Information System (INIS)

    Carrieri, C.; Masciopinto, C.

    2000-01-01

    Experimental studies have been carried out in a fractured coastal aquifer of the Salento Region (Nardo' (Le) Italy), subject since 1991 to injection of 12000 m 3 /d of treated municipal wastewater in a natural sink. The analytical parameters of ground water sampled in monitoring wells, have been compared before and after the injection started. The mound of water table (1.5 m), the reduction of seawater extent of 2 km and the spreading of pollutants injected were evaluated by means of mathematical model results. After ten years operation, the volume of the available resource for agricultural and drinking use has been increased, without notable decrease of the pre existent ground water quality. Moreover for preserving such resource from pollution, the mathematical model allowed the standards of wastewater quality for recharge to be identified. Around the sink, a restricted area was also defined with prohibition of withdrawals, to avoid infection and other risks on human health [it

  13. Effect of wastewater quality parameters on coliform inactivation by tin oxide anodes.

    Science.gov (United States)

    Teel, Amy L; Watts, Richard J

    2018-04-16

    The effect of six water quality constituents on wastewater effluent disinfection by tin oxide anodes (TOAs) was investigated in single cell laboratory reactors. Several concentrations of suspended solids, chemical oxygen demand (COD), alkalinity, ammonia-nitrogen, nitrite-nitrogen, and nitrate-nitrogen were added to media containing 10 6 total coliform bacteria mL -1 . Current was applied through the TOAs, and coliform bacteria viability was analyzed over time. Over 99.9% inactivation of coliform bacteria was found over 15 min in TOA reactors. Concentrations of the six water quality constituents typical of concentrations found in wastewaters had no effect on TOA disinfection efficacy. The results of this research demonstrate that TOAs, which could potentially be powered by solar panels, have potential as a sustainable disinfection process compared to chlorine, ozone, and ultraviolet light.

  14. Sekhukhune District Municipality workshop proceedings: Wastewater treatment: Towards improved water quality to promote social and economic development

    CSIR Research Space (South Africa)

    Ntombela, C

    2013-09-01

    Full Text Available The aim of the workshop was to reinforce, at the strategic decision-making level within the municipality, the significance of properly managed wastewater treatment facilities towards improved water quality....

  15. Control of DMSO in wastewater to prevent DMS nuisance odors.

    Science.gov (United States)

    Cheng, Xianhao; Wodarczyk, Michael; Lendzinski, Robert; Peterkin, Earl; Burlingame, Gary A

    2009-07-01

    A "canned corn-like" odor was periodically detected at Philadelphia's Northeast Water Pollution Control Plant (NEWPCP) for more than two decades. Previous research concluded that it was caused by dimethyl sulfide (DMS), from the reduction of dimethyl sulfoxide (DMSO) discharged by a local industrial customer. Several process modifications were implemented at the industrial site to eliminate the "canned corn-like" odor. Results showed that enhancing DMSO recovery by 25% and equalizing the aqueous wash discharge over a longer period of time reduced the DMSO source peak discharge from 1124 to 49 kg/h, and the peak concentrations of DMSO and DMS at the NEWPCP by 81 and 88%. Reduction of DMSO discharge by segregating the first wash for off-site disposal further reduced the peak discharge of DMSO from 49 to 18 kg/h at the source, and DMSO and DMS concentrations at the NEWPCP by 48 and 92%. Segregation of the dehydration distillate for off-site disposal reduced DMSO discharge by 3 kg/h. Modifications by concentrating a higher percentage of the DMSO into the first wash and increasing the DMSO solvent recovery by an additional 33% reduced the total DMSO discharge from 522 to 200 kg and peak discharge rate from 15 to 6 kg/h. All of these process modifications collectively reduced the DMSO source discharge by 92% and the DMSO concentration received at NEWPCP by 97%, from 12 mg/L to approximately 500 microg/L. At this reduced concentration, the company's wastewater discharge was no longer found to cause the "canned corn" odor at the fence line of NEWPCP, thereby mitigating any further need for odor control.

  16. Assessment of wastewater effluent quality in Thessaly region, Greece, for determining its irrigation reuse potential.

    Science.gov (United States)

    Bakopoulou, S; Emmanouil, C; Kungolos, A

    2011-02-01

    The objective of the present study is to assess wastewater effluent quality in Thessaly region, Greece, in relation to its physicochemical and microbiological burden as well as its toxic potential on a number of organisms. Wastewater may be used for agricultural as well as for landscape irrigation purposes; therefore, its toxicity potential is quite important. Thessaly region has been chosen since this region suffers from a distinct water shortage in summer period necessitating alternative water resources. During our research, treated effluents from four wastewater treatment plants operating in the region (Larissa, Volos, Karditsa, and Tirnavos) were tested for specific physicochemical and microbiological parameters [biochemical oxygen demand (BOD(5)), chemical oxygen demand (COD), total suspended solids (TSS), pH, electrical conductivity, selected metals presence (Cd, Co, Cr, Cu, Fe, Mn, Ni, Pb, Zn, As), and fecal coliforms' (FC) number]. The effluents were also tested for their toxicity using two different bioassays (Daphnia magna immobilization test and Phytotoxkit microbiotest). The findings were compared to relative regulations and guidelines regarding wastewater reuse for irrigation. The results overall show that secondary effluents in Thessaly region are generally acceptable for reuse for irrigation purposes according to limits set by legislation, if effective advanced treatment methods are applied prior to reuse. However, their potential toxicity should be closely monitored, since it was found that it may vary significantly in relation to season and location, when indicator plant and zooplankton organisms are used. Copyright © 2010 Elsevier Inc. All rights reserved.

  17. Validation and implementation of model based control strategies at an industrial wastewater treatment plant.

    Science.gov (United States)

    Demey, D; Vanderhaegen, B; Vanhooren, H; Liessens, J; Van Eyck, L; Hopkins, L; Vanrolleghem, P A

    2001-01-01

    In this paper, the practical implementation and validation of advanced control strategies, designed using model based techniques, at an industrial wastewater treatment plant is demonstrated. The plant under study is treating the wastewater of a large pharmaceutical production facility. The process characteristics of the wastewater treatment were quantified by means of tracer tests, intensive measurement campaigns and the use of on-line sensors. In parallel, a dynamical model of the complete wastewater plant was developed according to the specific kinetic characteristics of the sludge and the highly varying composition of the industrial wastewater. Based on real-time data and dynamic models, control strategies for the equalisation system, the polymer dosing and phosphorus addition were established. The control strategies are being integrated in the existing SCADA system combining traditional PLC technology with robust PC based control calculations. The use of intelligent control in wastewater treatment offers a wide spectrum of possibilities to upgrade existing plants, to increase the capacity of the plant and to eliminate peaks. This can result in a more stable and secure overall performance and, finally, in cost savings. The use of on-line sensors has a potential not only for monitoring concentrations, but also for manipulating flows and concentrations. This way the performance of the plant can be secured.

  18. Interaction between production control and quality control

    NARCIS (Netherlands)

    Bij, van der J.D.; Ekert, van J.H.W.

    1999-01-01

    Describes a qualitative study on interaction between systems for production control and quality control within industrial organisations. Production control and quality control interact in a sense. Good performance for one aspect often influences or frustrates the performance of the other. As far as

  19. Quality control in nuclear medicine

    International Nuclear Information System (INIS)

    Leme, P.R.

    1983-01-01

    The following topics are discussed: objectives of the quality control in nuclear medicine; the necessity of the quality control in nuclear medicine; guidelines and recommendations. An appendix is given concerning the guidelines for the quality control and instrumentation in nuclear medicine. (M.A.) [pt

  20. Printing quality control automation

    Science.gov (United States)

    Trapeznikova, O. V.

    2018-04-01

    One of the most important problems in the concept of standardizing the process of offset printing is the control the quality rating of printing and its automation. To solve the problem, a software has been developed taking into account the specifics of printing system components and the behavior in printing process. In order to characterize the distribution of ink layer on the printed substrate the so-called deviation of the ink layer thickness on the sheet from nominal surface is suggested. The geometric data construction the surface projections of the color gamut bodies allows to visualize the color reproduction gamut of printing systems in brightness ranges and specific color sectors, that provides a qualitative comparison of the system by the reproduction of individual colors in a varying ranges of brightness.

  1. Quality control in urinalysis.

    Science.gov (United States)

    Takubo, T; Tatsumi, N

    1999-01-01

    Quality control (QC) has been introduced in laboratories, and QC surveys in urinalysis have been performed by College of American Pathologist, by Japanese Association of Medical Technologists, by Osaka Medical Association and by manufacturers. QC survey in urinalysis for synthetic urine by the reagent strip and instrument made in same manufacturer, and by an automated urine cell analyser provided satisfactory results among laboratories. QC survey in urinalysis for synthetic urine by the reagent strips and instruments made by various manufacturers indicated differences in the determination values among manufacturers, and between manual and automated methods because the reagent strips and instruments have different characteristics, respectively. QC photo survey in urinalysis on the microscopic photos of urine sediment constituents indicated differences in the identification of cells among laboratories. From the results, it is necessary to standardize a reagent strip method, manual and automated methods, and synthetic urine.

  2. Storm water and wastewater management for improving water quality

    NARCIS (Netherlands)

    Boogaard, Floris; Vojinovic, Zoran; Heikoop, Rick

    Climate change and urbanization will increase the frequency and magnitude of urban flooding and water quality problems in many regions of the world. In coastal and delta areas like The Netherlands and the Philippines, where urbanization is often high, there has been an increase in the adoption of

  3. Nutrient management via struvite precipitation and recovery from various agroindustrial wastewaters: Process feasibility and struvite quality.

    Science.gov (United States)

    Taddeo, Raffaele; Honkanen, Mari; Kolppo, Kari; Lepistö, Raghida

    2018-04-15

    Improving environmental protection and finding sustainable and renewable resources of nutrients are core issues in circular bioeconomy. Thus, this study evaluated the efficiency of recovering struvite, MgNH 4 PO 4 ·6H 2 O, from different agro-industrial wastewaters (four highly loaded reject waters of anaerobically co-digested agro-industrial waste and a raw swine slurry) and assessed the quality of recovered struvite crystals and their reusability as fertilizer. The efficiency of crystallization (E c 40-80%) and amount of struvite in the precipitate (P p 55-94%) highly varied due to the characteristics of influent wastewaters, particularly to the content of competing elements, such as alkaline and heavy metals and total solids (TS). In particular, E c (94, 75, 61%) and P p (76, 66, 48%) decreased at increasing TS (0.57, 0.73, 0.99%), demonstrating the hindering effect of solid content on struvite recovery and quality. According to X-ray diffraction analysis, the structure of all isolated samples corresponded to crystalline, orthorhombic struvite, which exhibited high purity (32-48 g/kg d N, 114-132 g/kg d P, and 99-116 g/kg d Mg) containing only a few foreign elements, whose amount depended on the characteristics of the influent wastewater. All struvite contained other plant macronutrients (K, Ca) and many micronutrients (Fe, Na, Cu, Mn, Co, Zn) that further enhance its agronomic value. Therefore, this study showed that struvite can be successfully recovered from a wide range of highly loaded agroindustrial wastewaters, and that the quality of the recovered struvite could be suitable for reuse in agriculture. Copyright © 2018 Elsevier Ltd. All rights reserved.

  4. Adaptive model based control for wastewater treatment plants

    NARCIS (Netherlands)

    de Niet, Arie; van de Vrugt, Noëlle Maria; Korving, Hans; Boucherie, Richardus J.; Savic, D.A.; Kapelan, Z.; Butler, D.

    2011-01-01

    In biological wastewater treatment, nitrogen and phosphorous are removed by activated sludge. The process requires oxygen input via aeration of the activated sludge tank. Aeration is responsible for about 60% of the energy consumption of a treatment plant. Hence optimization of aeration can

  5. Identification of significant pressures and assessment of wastewater discharge on Krivaja River water quality

    Directory of Open Access Journals (Sweden)

    Pešić Vesna Z.

    2017-01-01

    Full Text Available One of the key stages of the process of preparing management plans for the river basin is the analysis of pressures and impacts, as well as the risk assessment of failing to achieve the environmental objectives. DPSIR framework (Driving Forces-Pressure-State-Impact-Response was developed by the European Agency for the environmental protection, and makes the conceptual basis for the pressures and impacts analysis, taking into account the complexity of the interactions in the environment and represents the tool for their analysis. Impact assessment of the water body requires some quantitative information to describe the condition of the water body and/or the pressures that act on it. The aim of the study was to determine the effect of wastewater discharge on Krivaja watercourse. Impact assessment is carried out based on data of polluters’ wastewater and monitoring information for water in Krivaja. For each site at which sampling was performed, the specific risk quotients for surface water were calculated, as the ratio of the each pollutant concentration in surface water at the sampling point and environmental quality standards for pollutants, as well as their sum that represents the risk index. In order to have the integrated perceive of processes in the Krivaja River, taking into account cumulative effects from point sources, the concept of total maximum daily load was applied, using which the pollution amount, that can be discharged daily in a water body without degrading his prescribed/required quality, was calculated. Comparison of emitted loads from pollution point sources with maximum allowable ones was performed. Wastewaters of different polluters located on Krivaja are, due to insufficient treatment, very loaded with organic matter and nutrients. Krivaja receives daily 1332 m3 of wastewater, 999 kg COD, 722 kg BOD, 144 kg of nitrogen, 4.3 kg of phosphorus and 627 kg of suspended solids. Of the total wastewater volume, the majority (69

  6. Recent developments in water quality monitoring for Space Station reclaimed wastewaters

    Science.gov (United States)

    Small, John W.; Verostko, Charles E.; Linton, Arthur T.; Burchett, Ray

    1987-01-01

    This paper discusses the recent developments in water quality monitoring for Space Station reclaimed wastewaters. A preprototype unit that contains an ultraviolet absorbance organic carbon monitor integrated with pH and conductivity sensors is presented. The preprototype has provisions for automated operation and is a reagentless flow-through system without any gas/liquid interfaces. The organic carbon monitor detects by utraviolet absorbance the organic impurities in reclaimed wastewater which may be correlated to the organic carbon content of the water. A comparison of the preprototype organic carbon detection values with actual total organic carbon measurements is presented. The electrolyte double junction concept for the pH sensor and fixed electrodes for both the pH and conductivity sensors are discussed. In addition, the development of a reagentless organic carbon analyzer that incorporates ultraviolet oxidation and infrared detection is presented. Detection sensitivities, hardware development, and operation are included.

  7. Control strategies for nitrous oxide emissions reduction on wastewater treatment plants operation.

    Science.gov (United States)

    Santín, I; Barbu, M; Pedret, C; Vilanova, R

    2017-11-15

    The present paper focused on reducing greenhouse gases emissions in wastewater treatment plants operation by application of suitable control strategies. Specifically, the objective is to reduce nitrous oxide emissions during the nitrification process. Incomplete nitrification in the aerobic tanks can lead to an accumulation of nitrite that triggers the nitrous oxide emissions. In order to avoid the peaks of nitrous oxide emissions, this paper proposes a cascade control configuration by manipulating the dissolved oxygen set-points in the aerobic tanks. This control strategy is combined with ammonia cascade control already applied in the literature. This is performed with the objective to take also into account effluent pollutants and operational costs. In addition, other greenhouse gases emissions sources are also evaluated. Results have been obtained by simulation, using a modified version of Benchmark Simulation Model no. 2, which takes into account greenhouse gases emissions. This is called Benchmark Simulation Model no. 2 Gas. The results show that the proposed control strategies are able to reduce by 29.86% of nitrous oxide emissions compared to the default control strategy, while maintaining a satisfactory trade-off between water quality and costs. Copyright © 2017 Elsevier Ltd. All rights reserved.

  8. Use of Treated Municipal Wastewater as Power Plant Cooling System Makeup Water: Tertiary Treatment versus Expanded Chemical Regimen for Recirculating Water Quality Management

    Energy Technology Data Exchange (ETDEWEB)

    David Dzombak; Radisav Vidic; Amy Landis

    2012-06-30

    Treated municipal wastewater is a common, widely available alternative source of cooling water for thermoelectric power plants across the U.S. However, the biodegradable organic matter, ammonia-nitrogen, carbonate and phosphates in the treated wastewater pose challenges with respect to enhanced biofouling, corrosion, and scaling, respectively. The overall objective of this study was to evaluate the benefits and life cycle costs of implementing tertiary treatment of secondary treated municipal wastewater prior to use in recirculating cooling systems. The study comprised bench- and pilot-scale experimental studies with three different tertiary treated municipal wastewaters, and life cycle costing and environmental analyses of various tertiary treatment schemes. Sustainability factors and metrics for reuse of treated wastewater in power plant cooling systems were also evaluated. The three tertiary treated wastewaters studied were: secondary treated municipal wastewater subjected to acid addition for pH control (MWW_pH); secondary treated municipal wastewater subjected to nitrification and sand filtration (MWW_NF); and secondary treated municipal wastewater subjected nitrification, sand filtration, and GAC adsorption (MWW_NFG). Tertiary treatment was determined to be essential to achieve appropriate corrosion, scaling, and biofouling control for use of secondary treated municipal wastewater in power plant cooling systems. The ability to control scaling, in particular, was found to be significantly enhanced with tertiary treated wastewater compared to secondary treated wastewater. MWW_pH treated water (adjustment to pH 7.8) was effective in reducing scale formation, but increased corrosion and the amount of biocide required to achieve appropriate biofouling control. Corrosion could be adequately controlled with tolytriazole addition (4-5 ppm TTA), however, which was the case for all of the tertiary treated waters. For MWW_NF treated water, the removal of ammonia by

  9. Wastewater control report for the Oak Ridge Y-12 Plant

    International Nuclear Information System (INIS)

    1996-06-01

    The 1995 National Pollutant Discharge Elimination System (NPDES) permit for the Y-12 Plant (Part III-F, page 41) requires the preparation of a report to describe procedures and criteria used in operating on-site treatment systems to maintain compliance with the NPDES permit. This report has been prepared to fulfill this requirement. Five wastewater treatment systems are currently in operation at the Y-12 Plant; they are operated by personal in the Waste Management and Facilities Management Organizations

  10. Impact assessment wastewater discharge on water quality DTD canal Bečej-Bogojevo

    Directory of Open Access Journals (Sweden)

    Pešić Vesna Ž.

    2015-01-01

    Full Text Available Pressure and impact analysis requires information on the main drivers and changes in conditions. In order to analyze such pressures and impacts, each river basin requires: an analysis of its characteristics, a review of the impact of human activity on the status of the surface water and an economic analysis of water use. Pressure and impact analysis plays a central role in the planning of river basin management. The quality of the stream at any point depends on several major factors: lithology of the basin, weather conditions, climate, and human impacts. Most of the polluters are located in the big cities next to canal DTD Bečej-Bogojevo canal (Odzaci,Vrbas, Srbobran, Becej. Per year, 2900000 m3 of wastewater was discharged into the Bečej-Bogojevo section of the DTD canal: 1,4 tCOD, 0,8 0tBOD, 260 kg of nitrogen, 19 kg of phosphorus and 282 kg of suspended solids. Of the total volume of wastewater, 20% comes from industry and 80% from municipal wastewater. Most of the wastewaters from the studied polluters is discharged untreated or insufficiently treated (only primary treatment. This poor quality wastewater threatens the receipients into which its is discharged. Comparison of the wastewater quality results to the Decree on emission limits and deadlines for their achievement, shows that many polluters exceed the limits for all parameters (COD, BOD, nitrogen, phosphorus, suspended solids. On the basis of the physico-chemical analysis of the water from the DTD Bečej-Bogojevo canal it can be concluded that the water quality is unsatisfactory. According to the national legislation, the water quality exceeds the values for good potential streams for most parameters at all sampling locatio dissolved oxygen, organic matter and nutrients. Thus, we can conclude that the water in the studied section of the DTD Bečej-Bogojevo canal does not meet the criteria for "good ecological potential". The most vulnerable locations are downstream of the Vrbas and

  11. Commercial jet fuel quality control

    Energy Technology Data Exchange (ETDEWEB)

    Strauss, K.H.

    1995-05-01

    The paper discusses the purpose of jet fuel quality control between the refinery and the aircraft. It describes fixed equipment, including various types of filters, and the usefulness and limitations of this equipment. Test equipment is reviewed as are various surveillance procedures. These include the Air Transport Association specification ATA 103, the FAA Advisory Circular 150/5230-4, the International Air Transport Association Guidance Material for Fuel Quality Control and Fuelling Service and the Guidelines for Quality Control at Jointly Operated Fuel Systems. Some past and current quality control problems are briefly mentioned.

  12. Evaluation of leachate dissolved organic nitrogen discharge effect on wastewater effluent quality.

    Science.gov (United States)

    Bolyard, Stephanie C; Reinhart, Debra R

    2017-07-01

    Nitrogen is limited more and more frequently in wastewater treatment plant (WWTP) effluents because of the concern of causing eutrophication in discharge waters. Twelve leachates from eight landfills in Florida and California were characterized for total nitrogen (TN) and dissolved organic nitrogen (DON). The average concentration of TN and DON in leachate was approximately 1146mg/L and 40mg/L, respectively. Solid-phase extraction was used to fractionate the DON based on hydrophobic (recalcitrant fraction) and hydrophilic (bioavailable fraction) chemical properties. The average leachate concentrations of bioavailable (bDON) and recalcitrant (rDON) DON were 16.5mg/L and 18.4mg/L, respectively. The rDON fraction was positively correlated, but with a low R 2 , with total leachate apparent color dissolved UV 254 , chemical oxygen demand (COD), and humic acid (R 2 equals 0.38, 0.49, and 0.40, respectively). The hydrophobic fraction of DON (rDON) was highly colored. This fraction was also associated with over 60% of the total leachate COD. Multiple leachate and wastewater co-treatment simulations were carried out to assess the effects of leachate on total nitrogen wastewater effluent quality using removals for four WWTPs under different scenarios. The calculated pass through of DON suggests that leachate could contribute to significant amounts of nitrogen discharged to aquatic systems. Copyright © 2017 Elsevier Ltd. All rights reserved.

  13. A voltammetric electronic tongue as tool for water quality monitoring in wastewater treatment plants.

    Science.gov (United States)

    Campos, Inmaculada; Alcañiz, Miguel; Aguado, Daniel; Barat, Ramón; Ferrer, José; Gil, Luis; Marrakchi, Mouna; Martínez-Mañez, Ramón; Soto, Juan; Vivancos, José-Luis

    2012-05-15

    The use of a voltammetric electronic tongue as tool for the prediction of concentration levels of certain water quality parameters from influent and effluent wastewater from a Submerged Anaerobic Membrane Bioreactor pilot plant applied to domestic wastewater treatment is proposed here. The electronic tongue consists of a set of noble (Au, Pt, Rh, Ir, and Ag) and non-noble (Ni, Co and Cu) electrodes that were housed inside a stainless steel cylinder which was used as the body of the electronic tongue system. As a previous step an electrochemical study of the response of the ions sulphate, orthophosphate, acetate, bicarbonate and ammonium was carried out in water using the electrodes contained in the electronic tongue. The second part of the work was devoted to the application of the electronic tongue to the characterization of the influent and effluent waters from the wastewater treatment plant. Partial Least Squares analysis was used to obtain a correlation between the data from the tongue and the pollution parameters measured in the laboratory such as soluble chemical oxygen demand (CODs), soluble biological oxygen demand (BODs), ammonia (NH(4)-N), orthophosphate (PO(4)-P), Sulphate (SO(4)-S), acetic acid (HAC) and alkalinity (Alk). A total of 28 and 11 samples were used in the training and the validation steps, respectively, for both influent and effluent water samples. The electronic tongue showed relatively good predictive power for the determination of BOD, COD, NH(4)-N, PO(4)-P, SO(4)-S, and Alk. Copyright © 2012 Elsevier Ltd. All rights reserved.

  14. Control of wastewater N2O emissions by balancing the microbial communities using a fuzzy-logic approach

    DEFF Research Database (Denmark)

    Boiocchi, Riccardo; Gernaey, Krist; Sin, Gürkan

    2016-01-01

    (approximately 35%). On the other side, this reduction of N2O was accompanied by an increase in the aeration costs. Moreover, a plant performance evaluation under dynamic disturbances shows that the effluent quality is compromised due to higher requirements of organic carbon by denitrifying heterotrophs....... The controller can therefore be considered effective for the reduction of N2O production by AOB but would need to be coupled with a secondary control strategy ensuring a complete oxidation of the nitrogen oxides by heterotrophs to have a good effluent quality.......In this work, a fuzzy-logic controller for minimization of the nitrous oxide emission from wastewater treatment plants is developed and tested in a simulation environment. The controller is designed in order to maintain a balance between production and consumption of nitrite by AOB and NOB...

  15. Managed aquifer recharge of treated wastewater: water quality changes resulting from infiltration through the vadose zone.

    Science.gov (United States)

    Bekele, Elise; Toze, Simon; Patterson, Bradley; Higginson, Simon

    2011-11-01

    Secondary treated wastewater was infiltrated through a 9 m-thick calcareous vadose zone during a 39 month managed aquifer recharge (MAR) field trial to determine potential improvements in the recycled water quality. The water quality improvements of the recycled water were based on changes in the chemistry and microbiology of (i) the recycled water prior to infiltration relative to (ii) groundwater immediately down-gradient from the infiltration gallery. Changes in the average concentrations of several constituents in the recycled water were identified with reductions of 30% for phosphorous, 66% for fluoride, 62% for iron and 51% for total organic carbon when the secondary treated wastewater was infiltrated at an applied rate of 17.5 L per minute with a residence time of approximately four days in the vadose zone and less than two days in the aquifer. Reductions were also noted for oxazepam and temazepam among the pharmaceuticals tested and for a range of microbial pathogens, but reductions were harder to quantify as their magnitudes varied over time. Total nitrogen and carbamazepine persisted in groundwater down-gradient from the infiltration galleries. Infiltration does potentially offer a range of water quality improvements over direct injection to the water table without passage through the unsaturated zone; however, additional treatment options for the non-potable water may still need to be considered, depending on the receiving environment or the end use of the recovered water. Crown Copyright © 2011. Published by Elsevier Ltd. All rights reserved.

  16. Soil Quality after Six Years of Paper Mill Industrial Wastewater Application

    Directory of Open Access Journals (Sweden)

    Ivan Carlos Carreiro Almeida

    Full Text Available ABSTRACT The application of wastewater to irrigate soils may be an attractive option for paper mills, especially when the effluents can also provide nutrients to plants. Since there could be negative environmental effects, such activity must be preceded by a thorough evaluation of the consequences. The changes in soil quality of a Neossolo Flúvico Distrófico (Typic Udifluvent were evaluated over a period of six years of irrigation with treated effluent from a wood pulp company. Although effluent application for six years did not affect soil resistance to penetration and soil hydraulic conductivity, it promoted a decrease in the mean size of aggregates and an increase in clay dispersion. Effluent application increased soil pH but did not change exchangeable Ca and Mg contents and organic carbon. After a full rotation of eucalyptus cultivation common in Brazil (six years, no negative effects in tree growth were found due to effluent irrigation. However, effluent addition caused higher values of Na adsorption ratio and intermediate electrical conductivity in the soil, which indicates a possible negative effect on soil quality if the application continues over a longer period. Therefore, a monitoring program should be carried out during subsequent crop rotations, and alternatives must be studied to obtain better effluent quality, such as adding Ca and Mg to the wastewater and using gypsum in the soil.

  17. INFORMATION SYSTEM QUALITY CONTROL KNOWLEDGE

    Directory of Open Access Journals (Sweden)

    Vladimir Nikolaevich Babeshko

    2017-02-01

    Full Text Available The development of the educational system is associated with the need to control the quality of educational services. Quality control knowledge is an important part of the scientific process. The penetration of computers into all areas of activities changing approaches and technologies that previously they were used.

  18. Water Quality Degradation and Management Strategies for Swine and Rice Farming Wastewater in the Tha Chin River Basin

    Directory of Open Access Journals (Sweden)

    Abigail Henderson

    2017-11-01

    Full Text Available Water quality in the Tha Chin River regularly exceeds biological oxygen demand (BOD standards of Thailand’s Enhancement and Conservation of National Environmental Quality Act. This study quantified the BOD loading from rice cultivation and swine farming to the Tha Chin River using effluent data and procedures from the Pollution Control Department (PCD, geospatial land-use maps from the Land Development Department, and water quality data from the Ministry of Natural Resources and the Environment. It was determined that the BOD loading was 12 tons/day from swine farming in 2015 and 52 tons/day, on average, from rice farming between 2002 and 2011. Technology-specific, community-scale wastewater management strategies were recommended for both industries: feasibility studies revealed 66 potential sites for constructed wetland implementation and 7 subdistricts suitable for biogas network pipelines. It was determined that if these projects are implemented in conjunction, the BOD would be reduced by 6% (0.3 mg/L in the entire river or 11% (0.5 mg/L at the three water quality monitoring stations proximate to swine farms. These reductions would have a substantial effect on the water quality of the Tha Chin River, and governmental agencies such as the PCD should strongly consider subsidization and implementation of these projects.

  19. Multiple response optimization of the coagulation process for upgrading the quality of effluent from municipal wastewater treatment plant

    Science.gov (United States)

    Li, Na; Hu, Yi; Lu, Yong-Ze; Zeng, Raymond J.; Sheng, Guo-Ping

    2016-05-01

    To meet the high quality standard of receiving water, the coagulation process using polyferric chloride (PFC) was used to further improve the water quality of effluent from wastewater treatment plants. Uniform design (UD) coupled with response surface methodology (RSM) was adopted to assess the effects of the main influence factors: coagulant dosage, pH and basicity, on the removal of total organic carbon (TOC), NH4+-N and PO43--P. A desirability function approach was used to effectively optimize the coagulation process for the comprehensive removal of TOC, NH4+-N and PO43--P to upgrade the effluent quality in practical application. The optimized operating conditions were: dosage 28 mg/L, pH 8.5 and basicity 0.001. The corresponding removal efficiencies for TOC, NH4+-N and PO43--P were 77.2%, 94.6% and 20.8%, respectively. More importantly, the effluent quality could upgrade to surface water Class V of China through coagulation under optimal region. In addition, grey relational analysis (GRA) prioritized these three factors as: pH > basicity > dosage (for TOC), basicity > dosage > pH (for NH4+-N), pH > dosage > basicity (for PO43--P), which would help identify the most important factor to control the treatment efficiency of various effluent quality indexes by PFC coagulation.

  20. Frontiers in statistical quality control

    CERN Document Server

    Wilrich, Peter-Theodor

    2004-01-01

    This volume treats the four main categories of Statistical Quality Control: General SQC Methodology, On-line Control including Sampling Inspection and Statistical Process Control, Off-line Control with Data Analysis and Experimental Design, and, fields related to Reliability. Experts with international reputation present their newest contributions.

  1. Effect of the presence of Actinomycetes in the activated sludge on the quality of the treated wastewater

    Directory of Open Access Journals (Sweden)

    Bezak-Mazur Elżbieta

    2017-01-01

    Full Text Available The aim of the study was to determine the effect of the Actinomycetes proliferation in the activated sludge on the quality of the treated wastewater and the sewage receiver. The river which is the sewage receiver flows near the wastewater treatment plant. The study was performed on the wastewater (raw and treated and on the river water samples (collected before and after wastewater discharge. The analysis of the research results, such as the content of total organic carbon (TOC, total phosphorus and oxygen consumption in the examined samples, permit the conclusion that the presence of relatively large population of the Actinomycetes in sewage sludge has a negative impact on the quality of the sewage receiver. Determining the effect of the Actinomycetes in the activated sludge on the wastewater treatment process involved the application of specific analyses, such as Sludge Biotic Index (SBI and the identification of filamentous bacteria in the activated sludge. The analysis of studies indicates that the presence of the Actinomycetes in the activated sludge adversely affects the efficiency of the wastewater treatment process.

  2. Process control, energy recovery and cost savings in acetic acid wastewater treatment

    International Nuclear Information System (INIS)

    Vaiopoulou, E.; Melidis, P.; Aivasidis, A.

    2011-01-01

    An anaerobic fixed bed loop (AFBL) reactor was applied for treatment of acetic acid (HAc) wastewater. Two pH process control concepts were investigated; auxostatic and chemostatic control. In the auxostatic pH control, feed pump is interrupted when pH falls below a certain pH value in the bioreactor, which results in reactor operation at maximum load. Chemostatic control assures alkaline conditions by setting a certain pH value in the influent, preventing initial reactor acidification. The AFBL reactor treated HAc wastewater at low hydraulic residence time (HRT) (10-12 h), performed at high space time loads (40-45 kg COD/m 3 d) and high space time yield (30-35 kg COD/m 3 d) to achieve high COD (Chemical Oxygen Demand) removal (80%). Material and cost savings were accomplished by utilizing the microbial potential for wastewater neutralization during anaerobic treatment along with application of favourable pH-auxostatic control. NaOH requirement for neutralization was reduced by 75% and HRT was increased up to 20 h. Energy was recovered by applying costless CO 2 contained in the biogas for neutralization of alkaline wastewater. Biogas was enriched in methane by 4 times. This actually brings in more energy profits, since biogas extra heating for CO 2 content during biogas combustion is minimized and usage of other acidifying agents is omitted.

  3. Quality assurance programme and quality control

    International Nuclear Information System (INIS)

    Alvarez de Buergo, L.

    1979-01-01

    The paper analyses the requirements for the quality assurance and control in nuclear power plant projects which are needed to achieve safe, reliable and economic plants. The author describes the structure for the establishment of a nuclear programme at the national level and the participation of the different bodies involved in a nuclear power plant project. The paper ends with the study of a specific case in Spain. (NEA) [fr

  4. Do contaminants originating from state-of-the-art treated wastewater impact the ecological quality of surface waters?

    Science.gov (United States)

    Stalter, Daniel; Magdeburg, Axel; Quednow, Kristin; Botzat, Alexandra; Oehlmann, Jörg

    2013-01-01

    Since the 1980s, advances in wastewater treatment technology have led to considerably improved surface water quality in the urban areas of many high income countries. However, trace concentrations of organic wastewater-associated contaminants may still pose a key environmental hazard impairing the ecological quality of surface waters. To identify key impact factors, we analyzed the effects of a wide range of anthropogenic and environmental variables on the aquatic macroinvertebrate community. We assessed ecological water quality at 26 sampling sites in four urban German lowland river systems with a 0-100% load of state-of-the-art biological activated sludge treated wastewater. The chemical analysis suite comprised 12 organic contaminants (five phosphor organic flame retardants, two musk fragrances, bisphenol A, nonylphenol, octylphenol, diethyltoluamide, terbutryn), 16 polycyclic aromatic hydrocarbons, and 12 heavy metals. Non-metric multidimensional scaling identified organic contaminants that are mainly wastewater-associated (i.e., phosphor organic flame retardants, musk fragrances, and diethyltoluamide) as a major impact variable on macroinvertebrate species composition. The structural degradation of streams was also identified as a significant factor. Multiple linear regression models revealed a significant impact of organic contaminants on invertebrate populations, in particular on Ephemeroptera, Plecoptera, and Trichoptera species. Spearman rank correlation analyses confirmed wastewater-associated organic contaminants as the most significant variable negatively impacting the biodiversity of sensitive macroinvertebrate species. In addition to increased aquatic pollution with organic contaminants, a greater wastewater fraction was accompanied by a slight decrease in oxygen concentration and an increase in salinity. This study highlights the importance of reducing the wastewater-associated impact on surface waters. For aquatic ecosystems in urban areas this

  5. Do Contaminants Originating from State-of-the-Art Treated Wastewater Impact the Ecological Quality of Surface Waters?

    Science.gov (United States)

    Stalter, Daniel; Magdeburg, Axel; Quednow, Kristin; Botzat, Alexandra; Oehlmann, Jörg

    2013-01-01

    Since the 1980s, advances in wastewater treatment technology have led to considerably improved surface water quality in the urban areas of many high income countries. However, trace concentrations of organic wastewater-associated contaminants may still pose a key environmental hazard impairing the ecological quality of surface waters. To identify key impact factors, we analyzed the effects of a wide range of anthropogenic and environmental variables on the aquatic macroinvertebrate community. We assessed ecological water quality at 26 sampling sites in four urban German lowland river systems with a 0–100% load of state-of-the-art biological activated sludge treated wastewater. The chemical analysis suite comprised 12 organic contaminants (five phosphor organic flame retardants, two musk fragrances, bisphenol A, nonylphenol, octylphenol, diethyltoluamide, terbutryn), 16 polycyclic aromatic hydrocarbons, and 12 heavy metals. Non-metric multidimensional scaling identified organic contaminants that are mainly wastewater-associated (i.e., phosphor organic flame retardants, musk fragrances, and diethyltoluamide) as a major impact variable on macroinvertebrate species composition. The structural degradation of streams was also identified as a significant factor. Multiple linear regression models revealed a significant impact of organic contaminants on invertebrate populations, in particular on Ephemeroptera, Plecoptera, and Trichoptera species. Spearman rank correlation analyses confirmed wastewater-associated organic contaminants as the most significant variable negatively impacting the biodiversity of sensitive macroinvertebrate species. In addition to increased aquatic pollution with organic contaminants, a greater wastewater fraction was accompanied by a slight decrease in oxygen concentration and an increase in salinity. This study highlights the importance of reducing the wastewater-associated impact on surface waters. For aquatic ecosystems in urban areas this

  6. Do contaminants originating from state-of-the-art treated wastewater impact the ecological quality of surface waters?

    Directory of Open Access Journals (Sweden)

    Daniel Stalter

    Full Text Available Since the 1980s, advances in wastewater treatment technology have led to considerably improved surface water quality in the urban areas of many high income countries. However, trace concentrations of organic wastewater-associated contaminants may still pose a key environmental hazard impairing the ecological quality of surface waters. To identify key impact factors, we analyzed the effects of a wide range of anthropogenic and environmental variables on the aquatic macroinvertebrate community. We assessed ecological water quality at 26 sampling sites in four urban German lowland river systems with a 0-100% load of state-of-the-art biological activated sludge treated wastewater. The chemical analysis suite comprised 12 organic contaminants (five phosphor organic flame retardants, two musk fragrances, bisphenol A, nonylphenol, octylphenol, diethyltoluamide, terbutryn, 16 polycyclic aromatic hydrocarbons, and 12 heavy metals. Non-metric multidimensional scaling identified organic contaminants that are mainly wastewater-associated (i.e., phosphor organic flame retardants, musk fragrances, and diethyltoluamide as a major impact variable on macroinvertebrate species composition. The structural degradation of streams was also identified as a significant factor. Multiple linear regression models revealed a significant impact of organic contaminants on invertebrate populations, in particular on Ephemeroptera, Plecoptera, and Trichoptera species. Spearman rank correlation analyses confirmed wastewater-associated organic contaminants as the most significant variable negatively impacting the biodiversity of sensitive macroinvertebrate species. In addition to increased aquatic pollution with organic contaminants, a greater wastewater fraction was accompanied by a slight decrease in oxygen concentration and an increase in salinity. This study highlights the importance of reducing the wastewater-associated impact on surface waters. For aquatic ecosystems in

  7. Process and technological options for odorous emissions control in wastewater treatment plants

    International Nuclear Information System (INIS)

    Cernuschi, S.; Torretta, V.

    1996-01-01

    The emissions of odorous substances together with noise and issues related to proper architectural design within the existing territorial context, have certainly to be considered one of the most significant environmental effects determined by wastewater treatment plants particularly in the most frequent case of their localization in dense urban areas. Following a brief introduction on the chemical properties of odorous compounds and the corresponding methods for representing their concentration levels in air, present work reports on the main qualitative and quantitative characteristics of odorous emissions originating from single unit operations of typical wastewater treatment plants and on the technological and process options available for their control

  8. Catchment & sewer network simulation model to benchmark control strategies within urban wastewater systems

    DEFF Research Database (Denmark)

    Saagi, Ramesh; Flores Alsina, Xavier; Fu, Guangtao

    2016-01-01

    This paper aims at developing a benchmark simulation model to evaluate control strategies for the urban catchment and sewer network. Various modules describing wastewater generation in the catchment, its subsequent transport and storage in the sewer system are presented. Global/local overflow based...... evaluation criteria describing the cumulative and acute effects are presented. Simulation results show that the proposed set of models is capable of generating daily, weekly and seasonal variations as well as describing the effect of rain events on wastewater characteristics. Two sets of case studies...

  9. Biological control and management of the detoxication wastewater treatment technologies

    Directory of Open Access Journals (Sweden)

    Topalova Yana

    2007-01-01

    Full Text Available Detoxication technologies require the combination of theoretical and practical knowledge of xenobiotic biodegradation, wastewater treatment technologies, and management rules. The purpose of this complicated combination is to propose specialized strategies for detoxication, based on lab- and pilot-scale modeling. These strategies include preliminary created algorithms for preventing the risk of water pollution and sediments. The technologies and algorithms are essentially important outcome, applied in the textile, pharmaceutical, cosmetic, woodtreating, and oiltreating industries. In this paper four rehabilitation technologies for pretreatment of water contaminated by pentachlorophenol (PCP have been developed in the frame of the European and Bulgarian National projects. Emphasize is put on the biological systems and their potential of detoxication management. The light and transmission electron microscopy of the reconstructed activated sludges the microbial, kinetic and enzymological indicators are presented and approved as critical points in the biocontrol.

  10. Multi-criteria evaluation of wastewater treatment plant control strategies under uncertainty

    DEFF Research Database (Denmark)

    Flores Alsina, Xavier; Rodriguez-Roda, Ignasi; Sin, Gürkan

    2008-01-01

    The evaluation of activated sludge control strategies in wastewater treatment plants (WWTP) via mathematical modelling is a complex activity because several objectives; e.g. economic, environmental, technical and legal; must be taken into account at the same time, i.e. the evaluation of the alter...

  11. Performance evaluation of a smart buffer control at a wastewater treatment plant

    NARCIS (Netherlands)

    van Daal-Rombouts, P.M.M.; Benedetti, L; Jonge, J; Weijers, S; Langeveld, J.G.

    2017-01-01

    Real time control (RTC) is increasingly seen as a viable method to optimise the functioning of wastewater systems. Model exercises and case studies reported in literature claim a positive impact of RTC based on results without uncertainty analysis and flawed evaluation periods. This paper describes

  12. Low-level wastewater treatment facility process control operational test report

    International Nuclear Information System (INIS)

    Bergquist, G.G.

    1996-01-01

    This test report documents the results obtained while conducting operational testing of a new TK 102 level controller and total outflow integrator added to the NHCON software that controls the Low-Level Wastewater Treatment Facility (LLWTF). The test was performed with WHC-SD-CP-OTP 154, PFP Low-Level Wastewater Treatment Facility Process Control Operational Test. A complete test copy is included in appendix A. The new TK 102 level controller provides a signal, hereafter referred to its cascade mode, to the treatment train flow controller which enables the water treatment process to run for long periods without continuous operator monitoring. The test successfully demonstrated the functionality of the new controller under standard and abnormal conditions expected from the LLWTF operation. In addition, a flow totalizer is now displayed on the LLWTF outlet MICON screen which tallies the process output in gallons. This feature substantially improves the ability to retrieve daily process volumes for maintaining accurate material balances

  13. Quality control of radiopharmaceuticals

    International Nuclear Information System (INIS)

    Wallen, O.; Komarov, E.

    1973-01-01

    The International Pharmacopoeia published by WHO constitutes a collection of recommended specifications for pharmaceutical preparations which are not intended to have legal status in any country, but serve as references so that national specifications can be established on a similar basis in any country. Like any pharmacopoeia, it contains monographs for the quality con trol of drugs by means of chemical, physical and simple biological methods, as well as appendices describing general methods. The work on the International Pharmacopoeia is carried out by WHO with the aid of the Expert Advisory Panel on the International Pharmacopoeia and Pharmaceutical Preparations and other specialists from various countries and the Expert Committee on Specifications for Pharmaceutical Preparations. (author)

  14. Quality control of labelled compounds

    International Nuclear Information System (INIS)

    Matucha, M.

    1979-01-01

    Some advantages and disadvantages of methods used for quality control of organic labelled compounds (1 31 I, 14 C) are shortly discussed. The methods used are electrophoresis, ultraviolet and infrared spectrometry, radiogas and thin-layer chromatography. (author)

  15. [Quality control in herbal supplements].

    Science.gov (United States)

    Oelker, Luisa

    2005-01-01

    Quality and safety of food and herbal supplements are the result of a whole of different elements as good manufacturing practice and process control. The process control must be active and able to individuate and correct all possible hazards. The main and most utilized instrument is the hazard analysis critical control point (HACCP) system the correct application of which can guarantee the safety of the product. Herbal supplements need, in addition to standard quality control, a set of checks to assure the harmlessness and safety of the plants used.

  16. Fuel cycle and quality control

    International Nuclear Information System (INIS)

    Stoll, W.

    1979-01-01

    The volume of the fuel cycle is described in its economic importance and its through put, as it is envisaged for the Federal Republic of Germany. Definitions are given for quality continuing usefulness of an object and translated into quality criteria. Requirements on performance of fuel elements are defined. The way in which experimental results are translated into mass production of fuel rods, is described. The economic potential for further quality effort is derived. Future ways of development for quality control organisation and structure are outlined. (Auth.)

  17. Impact of Combined Sewer Overflow on Wastewater Treatment and Microbiological Quality of Rivers for Recreation

    Directory of Open Access Journals (Sweden)

    Franz Mascher

    2017-11-01

    Full Text Available Within the framework of a one-year study the treatment capacity of a municipal wastewater treatment plant (WWTP was evaluated, with regard to fecal indicator bacteria (FIB and to their influence on the recipient. The logarithmic reduction rates for fecal coliforms (FC, Escherichia coli (EC and intestinal enterococci (IE were 2.84, 2.90 and 2.93. In the investigated period of time, the tested treatment plant released 4.3% of the total annual load flow volume as combined sewer overflow (CSO, that is, when the influent into the combined sewer exceeds the capacity of the treatment plant and coarsely cleaned wastewater arrives at the recipient. This CSO discharge increased the number of FIB significantly by 1.2 × 102 MPN/100 mL for EC, and by 1.8 × 101 MPN/100 mL for IE. For the Styrian part of the Mur River (1.6 million inhabitants, a calculation of FIB of all sewage treatment plants estimating the same ratio of CSO (4.3% and a given mean flow rate (QM results in a significant increase of the FIB load in the recipient: 3.8 × 103 MPN/100 mL for EC and 5.8 × 102 MPN/100 mL for IE. On the basis of these values the standards of water quality for recreational purposes cannot be met.

  18. SAQC: SNP Array Quality Control

    Directory of Open Access Journals (Sweden)

    Li Ling-Hui

    2011-04-01

    Full Text Available Abstract Background Genome-wide single-nucleotide polymorphism (SNP arrays containing hundreds of thousands of SNPs from the human genome have proven useful for studying important human genome questions. Data quality of SNP arrays plays a key role in the accuracy and precision of downstream data analyses. However, good indices for assessing data quality of SNP arrays have not yet been developed. Results We developed new quality indices to measure the quality of SNP arrays and/or DNA samples and investigated their statistical properties. The indices quantify a departure of estimated individual-level allele frequencies (AFs from expected frequencies via standardized distances. The proposed quality indices followed lognormal distributions in several large genomic studies that we empirically evaluated. AF reference data and quality index reference data for different SNP array platforms were established based on samples from various reference populations. Furthermore, a confidence interval method based on the underlying empirical distributions of quality indices was developed to identify poor-quality SNP arrays and/or DNA samples. Analyses of authentic biological data and simulated data show that this new method is sensitive and specific for the detection of poor-quality SNP arrays and/or DNA samples. Conclusions This study introduces new quality indices, establishes references for AFs and quality indices, and develops a detection method for poor-quality SNP arrays and/or DNA samples. We have developed a new computer program that utilizes these methods called SNP Array Quality Control (SAQC. SAQC software is written in R and R-GUI and was developed as a user-friendly tool for the visualization and evaluation of data quality of genome-wide SNP arrays. The program is available online (http://www.stat.sinica.edu.tw/hsinchou/genetics/quality/SAQC.htm.

  19. Data quality assurance in monitoring of wastewater quality: Univariate on-line and off-line methods

    DEFF Research Database (Denmark)

    Alferes, J.; Poirier, P.; Lamaire-Chad, C.

    To make water quality monitoring networks useful for practice, the automation of data collection and data validation still represents an important challenge. Efficient monitoring depends on careful quality control and quality assessment. With a practical orientation a data quality assurance proce...

  20. Multiple-endpoints gene alteration-based (MEGA) assay: A toxicogenomics approach for water quality assessment of wastewater effluents.

    Science.gov (United States)

    Fukushima, Toshikazu; Hara-Yamamura, Hiroe; Nakashima, Koji; Tan, Lea Chua; Okabe, Satoshi

    2017-12-01

    Wastewater effluents contain a significant number of toxic contaminants, which, even at low concentrations, display a wide variety of toxic actions. In this study, we developed a multiple-endpoints gene alteration-based (MEGA) assay, a real-time PCR-based transcriptomic analysis, to assess the water quality of wastewater effluents for human health risk assessment and management. Twenty-one genes from the human hepatoblastoma cell line (HepG2), covering the basic health-relevant stress responses such as response to xenobiotics, genotoxicity, and cytotoxicity, were selected and incorporated into the MEGA assay. The genes related to the p53-mediated DNA damage response and cytochrome P450 were selected as markers for genotoxicity and response to xenobiotics, respectively. Additionally, the genes that were dose-dependently regulated by exposure to the wastewater effluents were chosen as markers for cytotoxicity. The alterations in the expression of an individual gene, induced by exposure to the wastewater effluents, were evaluated by real-time PCR and the results were validated by genotoxicity (e.g., comet assay) and cell-based cytotoxicity tests. In summary, the MEGA assay is a real-time PCR-based assay that targets cellular responses to contaminants present in wastewater effluents at the transcriptional level; it is rapid, cost-effective, and high-throughput and can thus complement any chemical analysis for water quality assessment and management. Copyright © 2017 Elsevier Ltd. All rights reserved.

  1. Managing urban wastewater for maximising water resource utilisation

    CSIR Research Space (South Africa)

    Tredoux, G

    1999-10-01

    Full Text Available into components of distinctly different quality, and the separate treatment of domestic and industrial wastewater for different end-uses. The groundwater exploitation strategy is largely controlled by water quality requirements. Reuse of domestic and industrial...

  2. Frontiers in statistical quality control

    CERN Document Server

    Wilrich, Peter-Theodor

    2001-01-01

    The book is a collection of papers presented at the 5th International Workshop on Intelligent Statistical Quality Control in Würzburg, Germany. Contributions deal with methodology and successful industrial applications. They can be grouped in four catagories: Sampling Inspection, Statistical Process Control, Data Analysis and Process Capability Studies and Experimental Design.

  3. Applications of artificial intelligence technology to wastewater treatment fields in China

    Institute of Scientific and Technical Information of China (English)

    QING Xiao-xia; WANG Bo; MENG De-tao

    2005-01-01

    Current applications of artificial intelligence technology to wastewater treatment in China are summarized. Wastewater treatment plants use expert system mainly in the operation decision-making and fault diagnosis of system operation, use artificial neuron network for system modeling, water quality forecast and soft measure, and use fuzzy control technology for the intelligence control of wastewater treatment process. Finally, the main problems in applying artificial intelligence technology to wastewater treatment in China are analyzed.

  4. Principles and Practices for Quality Assurance and Quality Control

    Science.gov (United States)

    Jones, Berwyn E.

    1999-01-01

    Quality assurance and quality control are vital parts of highway runoff water-quality monitoring projects. To be effective, project quality assurance must address all aspects of the project, including project management responsibilities and resources, data quality objectives, sampling and analysis plans, data-collection protocols, data quality-control plans, data-assessment procedures and requirements, and project outputs. Quality control ensures that the data quality objectives are achieved as planned. The historical development and current state of the art of quality assurance and quality control concepts described in this report can be applied to evaluation of data from prior projects.

  5. Fluidized bed bio reactor sewage treatment system and wastewater quality at Kudankulam

    International Nuclear Information System (INIS)

    Vijayakumar, B.; George, Thomas; Rajan, P.S.; Kumar, M.; Rajan, M.P.

    2006-01-01

    With the availability of fresh water becoming exiguous in certain coastal belts, it has become imperative to manage water resources in a resourceful and judicious manner. The focus has also shifted to minimum or zero tolerance from existing waste treatment plants so as not to contaminate or pollute the already shrinking drinking water resources. Many of the modern waste treatment approaches are already aiming at zero discharge with a view to conserving the ecological balance and to protect the rich bio diversity, flora and fauna. This paper describes one such domestic sewage treatment system called fluidized bed bio reactor operating in the residential colony and plant site area of Kudankulam Nuclear Power Project. Wastewater quality of the resulting effluent water is also discussed. (author)

  6. Evaluation of water quality functions of conventional and advanced soil-based onsite wastewater treatment systems.

    Science.gov (United States)

    Cooper, Jennifer A; Loomis, George W; Kalen, David V; Amador, Jose A

    2015-05-01

    Shallow narrow drainfields are assumed to provide better wastewater renovation than conventional drainfields and are used for protection of surface and ground water. To test this assumption, we evaluated the water quality functions of two advanced onsite wastewater treatment system (OWTS) drainfields-shallow narrow (SND) and Geomat (GEO)-and a conventional pipe and stone (P&S) drainfield over 12 mo using replicated ( = 3) intact soil mesocosms. The SND and GEO mesocosms received effluent from a single-pass sand filter, whereas the P&S received septic tank effluent. Between 97.1 and 100% of 5-d biochemical oxygen demand (BOD), fecal coliform bacteria, and total phosphorus (P) were removed in all drainfield types. Total nitrogen (N) removal averaged 12.0% for P&S, 4.8% for SND, and 5.4% for GEO. A mass balance analysis accounted for 95.1% (SND), 94.1% (GEO), and 87.6% (P&S) of N inputs. When the whole treatment train (excluding the septic tank) is considered, advanced systems, including sand filter pretreatment and SND or GEO soil-based treatment, removed 99.8 to 99.9% of BOD, 100% of fecal coliform bacteria and P, and 26.0 to 27.0% of N. In contrast, the conventional system removed 99.4% of BOD and 100% of fecal coliform bacteria and P but only 12.0% of N. All drainfield types performed similarly for most water quality functions despite differences in placement within the soil profile. However, inclusion of the pretreatment step in advanced system treatment trains results in better N removal than in conventional treatment systems despite higher drainfield N removal rates in the latter. Copyright © by the American Society of Agronomy, Crop Science Society of America, and Soil Science Society of America, Inc.

  7. Plant-wide modelling and control of nitrous oxide emissions from wastewater treatment plants

    DEFF Research Database (Denmark)

    Boiocchi, Riccardo

    Nitrous oxide (N2O) is a greenhouses gas with a global warming potential three hundred times stronger than carbon dioxide (CO2). The IPCC report released in 2014 shows that the CO2 equivalents emitted from the wastewater systems are increasing in the last decades. It was also estimated that 14......% of those CO2 equivalents comes from N2O emissions. It becomes therefore relevant, within the context of reducing the carbon footprint of wastewater treatment (WWT) systems, to develop control strategies aimed at the minimization of the emissions of this gas. Till now, few operation strategies have been....... To avoid poor performance behaviour due to intuitive design, a systematic procedure for the design of fuzzy-logic controllers is developed using a partial nitritation/Anammox system as application case. The same systematic methodology is then adopted to tune the fuzzy-logic controller for low N2O emissions...

  8. Coupling of weather forecasts and smart grid-control of wastewater inlet to Kolding WWTP (Denmark)

    DEFF Research Database (Denmark)

    Evald Bjerg, Julie; Grum, Morten; Courdent, Vianney Augustin Thomas

    2015-01-01

    The increasing focus on renewable energy sources has caused many countries to initiate a shift to a more intelligent and flexible electricity system – the Smart Grid. This allows for the optimization of the electricity consumption according to the fluctuation in electricity prices. In this study...... four strategies for controlling the wastewater flow to Kolding Central wastewater treatment plant (WWTP) based on the Smart Grid concept are investigated. The control strategies use the storage volume in the pipe system upstream the WWTP to detain water during hours with high electricity prices......, releasing the water when the price decreases. A lumped conceptual model was constructed based an existing highly detailed hydrodynamic model of the catchment. The conceptual model was used to assess the performance of the four control strategies, which were evaluated based on savings in operation cost...

  9. Quality Control - Nike.Inc

    OpenAIRE

    Walter G. Bishop

    2017-01-01

    The purpose of this paper is to present the illustration of quality control approach, which has been adopted by several organizations, in order to manage and improve their production processes. The approach is referred as total quality management (TQM). This study will discuss the implementation of TQ, within the working environment of Nike Inc. One of the major objectives behind the implementation of TQ is to reduce or completely eliminate potential errors and flaws, within the manufacturing...

  10. SBR treatment of tank truck cleaning wastewater: sludge characteristics, chemical and ecotoxicological effluent quality.

    Science.gov (United States)

    Caluwé, Michel; Dobbeleers, Thomas; Daens, Dominique; Geuens, Luc; Blust, Ronny; Dries, Jan

    2017-08-02

    A lab-scale activated sludge sequencing batch reactor (SBR) was used to treat tank truck cleaning (TTC) wastewater with different operational strategies (identified as different stages). The first stage was an adaptation period for the seed sludge that originated from a continuous fed industrial plant treating TTC wastewater. The first stage was followed by a dynamic reactor operation based on the oxygen uptake rate (OUR). Thirdly, dynamic SBR control based on OUR treated a daily changing influent. Lastly, the reactor was operated with a gradually shortened fixed cycle. During operation, sludge settling evolved from nearly no settling to good settling sludge in 16 days. The sludge volume index improved from 200 to 70 mL gMLSS -1 in 16 days and remained stable during the whole reactor operation. The average soluble chemical oxygen demand (sCOD) removal varied from 87.0% to 91.3% in the different stages while significant differences in the food to mass ratio were observed, varying from 0.11 (stage I) to 0.37 kgCOD.(kgMLVSS day) -1 (stage III). Effluent toxicity measurements were performed with Aliivibrio fischeri, Daphnia magna and Pseudokirchneriella subcapitata. Low sensitivity of Aliivibrio was observed. A few samples were acutely toxic for Daphnia; 50% of the tested effluent samples showed an inhibition of 100% for Pseudokirchneriella.

  11. Quality assurance, quality control and quality audit in diagnostic radiology

    International Nuclear Information System (INIS)

    Vassileva, J.

    2009-01-01

    Full text:The lecture aims to present contemporary view of quality assurance in X-Ray diagnosis and its practical realization in Bulgaria. In the lecture the concepts of quality assurance, quality control and clinical audit will be defined and their scope will be considered. An answer of the following questions will be given: why is it necessary to determine the dose of patient in X-ray studies, what is the reference dose level and how it is used for dosimetric quantity which characterized the patient's exposure in X-ray, mammography and CT scans and how they are measured, who conducted the measurement and how to keep the records, what are the variations of doses in identical tests and what defines them? The findings from a national survey of doses in diagnostic radiology, conducted in 2008-2009 and the developed new national reference levels will be presented. The main findings of the first tests of radiological equipment and the future role of quality control as well as the concept of conducting clinical audit and its role in quality assurance are also presented. Quality assurance of the diagnostic process with minimal exposure of patients is a strategic goal whose realization requires understanding, organization and practical action, both nationally and in every hospital. To achieve this the important role of education and training of physicians, radiological technicians and medical physicists is enhanced

  12. Quality control of imaging devices

    International Nuclear Information System (INIS)

    Soni, P.S.

    1992-01-01

    Quality assurance in nuclear medicine refers collectively to all aspects of a nuclear medicine service. It would include patient scheduling, radiopharmaceutical preparation and dispensing, radiation protection of patients, staff and general public, preventive maintenance and the care of instruments, methodology, data interpretation and records keeping, and many other small things which contribute directly or indirectly to the overall quality of a nuclear medicine service in a hospital. Quality Control, on the other hand, refers to a signal component of the system and is usually applied in relation to a specific instrument and its performance

  13. Quality control for dose calibrators

    International Nuclear Information System (INIS)

    Mendes, L.C.G.

    1984-01-01

    Nuclear medicine laboratories are required to assay samples of radioactivity to be administered to patients. Almost universally, these assays are accomplished by use of a well ionization chamber isotope calibrator. The Instituto de Radioprotecao e Dosimetria (Institute for Radiological Protection and Dosimetry) of the Comissao Nacional de Energia Nuclear (National Commission for Nuclear Energy) is carrying out a National Quality Control Programme in Nuclear Medicine, supported by the International Atomic Energy Agency. The assessment of the current needs and practices of quality control in the entire country of Brazil includes Dose Calibrators and Scintillation Cameras, but this manual is restricted to the former. Quality Control Procedures for these Instruments are described in this document together with specific recommendations and assessment of its accuracy. (author)

  14. Wastewater Characteristics, Treatment and Disposal

    OpenAIRE

    Von Sperling, Marcos

    2007-01-01

    "Wastewater Characteristics, Treatment and Disposal is the first volume in the series Biological Wastewater Treatment, presenting an integrated view of water quality and wastewater treatment. The book covers the following topics: wastewater characteristics (flow and major constituents) impact of wastewater discharges to rivers and lakes overview of wastewater treatment systems complementary items in planning studies. This book, with its clear and practical approach, lays the foundations f...

  15. Quality of wastewater used for conventional irrigation in the vicinity of lahore and its impact on receiving soils and vegetables

    International Nuclear Information System (INIS)

    Bashir, F.; Tariq, M.; Khan, R.A.; Shafiq, T.

    2014-01-01

    The quality of wastewater was evaluated from Rohi Nullah, Lahore, Pakistan, for one year (2008-2009) from those points where it is used for irrigation of crops on both sides of Nullah. The quality of wastewater was evaluated for pollution load including pH, sulphide, phenol, methylene blue active substances, chemical oxygen demand (COD), biochemical oxygen demand (BOD), irrigation quality (electric conductivity, total dissolved solids, total suspended solids, sodium adsorption ratio, residual sodium carbonate and chlorides) nutritional value (total nitrogen, total phosphorus and total potassium) and for metal concentration. The metals analysed were cadmium, nickel, chromium, zinc, manganese, cobalt and copper. With respect to pollution load BOD, COD and sulphide concentration was above the National Environmental Quality Standard (NEQS) limit. Nitrogen and phosphorus were contained at levels of concern in wastewater but the level of potassium was below crop requirements. The concentration of nickel, chromium, manganese and copper was above the FAO standards, while the concentration of cadmium, zinc and cobalt fell within FAO standards. Considering NEQS standards, the metals concentration was within limits. Temporal variations were prominent in some parameters and mostly higher values were observed in summer and lower in winter season. There was accumulation of heavy metals in soils receiving wastewater for irrigation. The metal contents in soils follow the order Mn> Co> Zn> Cr > Ni > Cu > Cd. It was observed that the concentration of all studied toxic metals in edible part of the vegetables was above the critical level. Finally, it was concluded that the practice of using wastewater in irrigation for growing vegetables and other crops is non-sustainable. (author)

  16. DSC: software tool for simulation-based design of control strategies applied to wastewater treatment plants.

    Science.gov (United States)

    Ruano, M V; Ribes, J; Seco, A; Ferrer, J

    2011-01-01

    This paper presents a computer tool called DSC (Simulation based Controllers Design) that enables an easy design of control systems and strategies applied to wastewater treatment plants. Although the control systems are developed and evaluated by simulation, this tool aims to facilitate the direct implementation of the designed control system to the PC of the full-scale WWTP (wastewater treatment plants). The designed control system can be programmed in a dedicated control application and can be connected to either the simulation software or the SCADA of the plant. To this end, the developed DSC incorporates an OPC server (OLE for process control) which facilitates an open-standard communication protocol for different industrial process applications. The potential capabilities of the DSC tool are illustrated through the example of a full-scale application. An aeration control system applied to a nutrient removing WWTP was designed, tuned and evaluated with the DSC tool before its implementation in the full scale plant. The control parameters obtained by simulation were suitable for the full scale plant with only few modifications to improve the control performance. With the DSC tool, the control systems performance can be easily evaluated by simulation. Once developed and tuned by simulation, the control systems can be directly applied to the full-scale WWTP.

  17. Enhancing mercury removal across air pollution control devices for coal-fired power plants by desulfurization wastewater evaporation.

    Science.gov (United States)

    Bin, Hu; Yang, Yi; Cai, Liang; Yang, Linjun; Roszak, Szczepan

    2017-10-09

    Desulfurization wastewater evaporation technology is used to enhance the removal of gaseous mercury (Hg) in conventional air pollution control devices (APCDs) for coal-fired power plants. Studies have affirmed that gaseous Hg is oxidized and removed by selective catalytic reduction (SCR), an electrostatic precipitator (ESP) and wet flue gas desulfurization (WFGD) in a coal-fired thermal experiment platform with WFGD wastewater evaporation. Effects of desulfurization wastewater evaporation position, evaporation temperature and chlorine ion concentration on Hg oxidation were studied as well. The Hg 0 oxidation efficiency was increased ranging from 30% to 60%, and the gaseous Hg removal efficiency was 62.16% in APCDs when wastewater evaporated before SCR. However, the Hg 0 oxidation efficiency was 18.99% and the gaseous Hg removal efficiency was 40.19% in APCDs when wastewater evaporated before ESP. The results show that WFGD wastewater evaporation before SCR is beneficial to improve the efficiency of Hg oxidized and removed in APCDs. Because Hg 2+ can be easily removed in ACPDs and WFGD wastewater in power plants is enriched with chlorine ions, this method realizes WFGD wastewater zero discharge and simultaneously enhances Hg removal in APCDs.

  18. Combination of Electrochemical Processes with Membrane Bioreactors for Wastewater Treatment and Fouling Control: A Review

    OpenAIRE

    Ensano, Benny M. B.; Borea, Laura; Naddeo, Vincenzo; Belgiorno, Vincenzo; de Luna, Mark D. G.; Ballesteros, Florencio C.

    2016-01-01

    This paper provides a critical review about the integration of electrochemical processes into membrane bioreactors (MBR) in order to understand the influence of these processes on wastewater treatment performance and membrane fouling control. The integration can be realized either in an internal or an external configuration. Electrically enhanced membrane bioreactors or electro membrane bioreactors (eMBRs) combine biodegradation, electrochemical and membrane filtration processes into one syst...

  19. Combination of electrochemical processes with membrane bioreactors for wastewater treatment and fouling control: A review

    OpenAIRE

    Benny Marie B. Ensano; Laura Borea; Vincenzo Naddeo; Vincenzo Belgiorno; Mark Daniel G. de Luna; Mark Daniel G. de Luna; Florencio C. Ballesteros, Jr.; Florencio C. Ballesteros, Jr.

    2016-01-01

    This paper provides a critical review about the integration of electrochemical processes into membrane bioreactors (MBR) in order to understand the influence of these processes on wastewater treatment performance and membrane fouling control. The integration can be realized either in an internal or an external configuration. Electrically enhanced membrane bioreactors or electro membrane bioreactors (eMBRs) combine biodegradation, electrochemical and membrane filtration processes into one syst...

  20. Frontiers in statistical quality control

    CERN Document Server

    Wilrich, Peter-Theodor

    1997-01-01

    Like the preceding volumes, and met with a lively response, the present volume is collecting contributions stressed on methodology or successful industrial applications. The papers are classified under four main headings: sampling inspection, process quality control, data analysis and process capability studies and finally experimental design.

  1. Quality assurance and statistical control

    DEFF Research Database (Denmark)

    Heydorn, K.

    1991-01-01

    In scientific research laboratories it is rarely possible to use quality assurance schemes, developed for large-scale analysis. Instead methods have been developed to control the quality of modest numbers of analytical results by relying on statistical control: Analysis of precision serves...... to detect analytical errors by comparing the a priori precision of the analytical results with the actual variability observed among replicates or duplicates. The method relies on the chi-square distribution to detect excess variability and is quite sensitive even for 5-10 results. Interference control...... serves to detect analytical bias by comparing results obtained by two different analytical methods, each relying on a different detection principle and therefore exhibiting different influence from matrix elements; only 5-10 sets of results are required to establish whether a regression line passes...

  2. Estimation of water quality by UV/Vis spectrometry in the framework of treated wastewater reuse.

    Science.gov (United States)

    Carré, Erwan; Pérot, Jean; Jauzein, Vincent; Lin, Liming; Lopez-Ferber, Miguel

    2017-07-01

    The aim of this study is to investigate the potential of ultraviolet/visible (UV/Vis) spectrometry as a complementary method for routine monitoring of reclaimed water production. Robustness of the models and compliance of their sensitivity with current quality limits are investigated. The following indicators are studied: total suspended solids (TSS), turbidity, chemical oxygen demand (COD) and nitrate. Partial least squares regression (PLSR) is used to find linear correlations between absorbances and indicators of interest. Artificial samples are made by simulating a sludge leak on the wastewater treatment plant and added to the original dataset, then divided into calibration and prediction datasets. The models are built on the calibration set, and then tested on the prediction set. The best models are developed with: PLSR for COD (R pred 2 = 0.80), TSS (R pred 2 = 0.86) and turbidity (R pred 2 = 0.96), and with a simple linear regression from absorbance at 208 nm (R pred 2 = 0.95) for nitrate concentration. The input of artificial data significantly enhances the robustness of the models. The sensitivity of the UV/Vis spectrometry monitoring system developed is compatible with quality requirements of reclaimed water production processes.

  3. Validating data quality during wet weather monitoring of wastewater treatment plant influents

    DEFF Research Database (Denmark)

    Alferes, Janelcy; Lynggaard-Jensen, Anders; Munk-Nielsen, Thomas

    Efficient monitoring of water systems and proper use of the collected data in further applications such as modelling, forecasting influent water quality and real-time control depends on careful data quality control. Given the size of the data sets produced nowadays in online water quality...... monitoring schemes, automated data validation is the only feasible option. In this paper, software tools for automatic data quality assessment with a practical orientation are presented. The developments from three organizations ranging from simple to more complex methods for automated data validation...

  4. Effects of winery wastewater on soil, grape nutrition, and wine quality

    Science.gov (United States)

    Many wineries are interested in recycling wastewater for irrigation. This project investigates the effects on winemaking when winery wastewater (WW) is recycledfor irrigation. Water samples and soils samples were collected from one Napa Valley and one Sonoma vineyard. Leaf and berry samples were col...

  5. Quality Assurance/Quality Control Jobs

    Science.gov (United States)

    Fanslau, Melody; Young, Janelle

    The production of a quality and safe food product is essential to the success of any food manufacturing facility. Because of this great importance, a career in quality can be extremely rewarding. Without happy customers willing to buy a product, a company would not be able to survive. Quality issues such as foreign objects, spoiled or mislabeled product, failure to meet net weight requirements, or a recall can all turn customers away from buying a product. The food industry is a customer-driven market in which some consumers are brand loyal based on a history of high quality or in which a single bad experience with a product will turn them away for a lifetime. With this said, the main role of a quality department is to help ensure that quality issues such as these are eliminated or kept to a minimum to maintain or increase the number of customers purchasing their product.

  6. Control of quality in mammography

    International Nuclear Information System (INIS)

    2006-10-01

    The present protocol of quality control/quality assurance in mammography is the result of the work of two regional projects realised in Latin America within the frame of ARCAL with the support of the IAEA. The first is ARCAL LV (RLA/6/043) project on quality assurance/quality control in mammography studies which analysed the present situation of the mammography in the member countries of the project which include: Bolivia, Colombia, Costa Rica, Cuba, El Salvador, Guatemala, Nicaragua, Panama, Paraguay, Peru, Dominican Republic and Republic of Venezuela and the second is ARCAL XLIX (RLA/9/035) project, whose members were Brazil, Colombia, Cuba, Chile, Mexico, and Peru, worked the application of Basic Safety Standards for the protection against ionising radiation with the aim to improve radiation protection in X-ray diagnosis medical practices through the implementation of the Basic Safety Standards (BSS) related to x-ray diagnosis in selected hospitals located in each country involved in the project. The work of both projects had been consolidated and harmonized in the present publication

  7. The use of treated wastewater for chemlali olive tree irrigation: effects on soil properties, growth and oil quality

    Energy Technology Data Exchange (ETDEWEB)

    Ben Rouina, B.; Bedbabis, S.; Ben Ahmed, C.; Boukhris, M.

    2009-07-01

    Olive tree (Olea european L.) cultivation, the major tree crops in Mediterranean countries is being extended to irrigated lands. However, the limited water availability, the severe climatic conditions and the increased need for good water quality for urban and industrial sector uses are leading to the urgent use of less water qualities (brackish water and recycled wastewater) for olive tree irrigation. The aim of this work was to asses the effects of long term irrigation with treated waste water (TWW) on the soil chemical properties, on olive tree growth and on oil quality characteristics. (Author)

  8. The use of treated wastewater for chemlali olive tree irrigation: effects on soil properties, growth and oil quality

    International Nuclear Information System (INIS)

    Ben Rouina, B.; Bedbabis, S.; Ben Ahmed, C.; Boukhris, M.

    2009-01-01

    Olive tree (Olea european L.) cultivation, the major tree crops in Mediterranean countries is being extended to irrigated lands. However, the limited water availability, the severe climatic conditions and the increased need for good water quality for urban and industrial sector uses are leading to the urgent use of less water qualities (brackish water and recycled wastewater) for olive tree irrigation. The aim of this work was to asses the effects of long term irrigation with treated waste water (TWW) on the soil chemical properties, on olive tree growth and on oil quality characteristics. (Author)

  9. Potential effects of desalinated water quality on the operation stability of wastewater treatment plants.

    Science.gov (United States)

    Lew, Beni; Cochva, Malka; Lahav, Ori

    2009-03-15

    Desalinated water is expected to become the major source of drinking water in many places in the near future, and thus the major source of wastewater to arrive at wastewater treatment plants. The paper examines the effect of the alkalinity value with which the water is released from the desalination plant on the alkalinity value that would develop within the wastewater treatment process under various nitrification-denitrification operational scenarios. The main hypothesis was that the difference in the alkalinity value between tap water and domestic wastewater is almost exclusively a result of the hydrolysis of urea (NH(2)CONH(2), excreted in the human urine) to ammonia (NH(3)), regardless of the question what fraction of NH(3(aq)) is transformed to NH(4)(+). Results from a field study show that the ratio between the alkalinity added to tap water when raw wastewater is formed (in meq/l units) and the TAN (total ammonia nitrogen, mole/l) concentration in the raw wastewater is almost 1:1 in purely domestic sewage and close to 1:1 in domestic wastewater streams mixed with light industry wastewaters. Having established the relationship between TAN and total alkalinity in raw wastewater the paper examines three theoretical nitrification-denitrification treatment scenarios in the wastewater treatment plant (WWTP). The conclusion is that if low-alkalinity desalinated water constitutes the major water source arriving at the WWTP, external alkalinity will have to be added in order to avoid pH drop and maintain process stability. The results lead to the conclusion that supplying desalinated water with a high alkalinity value (e.g. > or =100 mg/l as CaCO(3)) would likely prevent the need to add costly basic chemicals in the WWTP, while, in addition, it would improve the chemical and biological stability of the drinking water in the distribution system.

  10. quality control of the radiopharmaceuticals

    International Nuclear Information System (INIS)

    Boukarra, Hajer; Boubakri, Rania

    2006-01-01

    This work is a contribution to the quality control of two radio pharmaceutical. Our study was carried out on the rat. These results enable us to draw the following conclusions: - the control of the purity of the cerebral tracers (Cytectrenes) is carried out by HPLC by using a detector of radioactivity which offers a great sensitivity. - the radiochemical output of marking of Kit MDP determined by thin chromatography of layer is 99%. - The study of the biodistribution in the rat showed an affinity raised for the feet bone. - These results are in conformity with the European pharmacopoeia, which enables us to require a marketing authorization. (author)

  11. Effects of residential wastewater treatment systems on ground-water quality in west-central Jefferson County, Colorado

    Science.gov (United States)

    Hall, Dennis C.; Hillier, D.E.; Nickum, Edward; Dorrance, W.G.

    1981-01-01

    The use of residential wastewater-treatment systems in Evergreen Meadows, Marshdale, and Herzman Mesa, Colo., has degraded ground-water quality to some extent in each community. Age of community; average lot size; slope of land surface; composition, permeability, and thickness of surficial material; density, size , and orientation of fractures; maintenance of wastewater-treatment systems; and presence of animals are factors possibly contributing to the degradation of ground-water quality. When compared with effluent from aeration-treatment tanks, effluent fom septic-treatment tanks is characterized by greater biochemical oxygen demand and greater concentrations of detergents. When compared with effluent from septic-treatment tanks, effluent from aeration-treatment tanks is characterized by greater concentrations of dissolved oxygen, nitrite, nitrate, sulfate, and dissolved solids. (USGS)

  12. Radiation measurements and quality control

    International Nuclear Information System (INIS)

    McLaughlin, W.L.

    1977-01-01

    Accurate measurements are essential to research leading to a successful radiation process and to the commissioning of the process and the facility. On the other hand, once the process is in production, the importance to quality control of measuring radiation quantities (i.e., absorbed dose, dose rate, dose distribution) rather than various other parameters of the process (i.e. conveyor speed, dwell time, radiation field characteristics, product dimensions) is not clearly established. When the safety of the product is determined by the magnitude of the administered dose, as in radiation sterilization, waste control, or food preservation, accuracy and precision of the measurement of the effective dose are vital. Since physical dose measurements are usually simpler, more reliable and reproducible than biological testing of the product, there is a trend toward using standardized dosimetry for quality control of some processes. In many industrial products, however, such as vulcanized rubber, textiles, plastics, coatings, films, wire and cable, the effective dose can be controlled satisfactorily by controlling process variables or by product testing itself. In the measurement of radiation dose profiles by dosimetry, it is necessary to have suitable dose meter calibrations, to account for sources of error and imprecision, and to use correct statistical procedures in specifying dwell times or conveyor speeds and source and product parameters to achieve minimum and maximum doses within specifications. (author)

  13. Metrology and quality control handbook

    International Nuclear Information System (INIS)

    Hofmann, D.

    1983-01-01

    This book tries to present the fundamentals of metrology and quality control in brief surveys. Compromises had to be made in order to reduce the material available to a sensible volume for the sake of clarity. This becomes evident by the following two restrictions which had to made: First, in dealing with the theoretical principles of metrology and quality control, mere reference had to be made in many cases to the great variety of special literature without discussing it to explain further details. Second, in dealing with the application of metrology and quality control techniques in practice, only the basic qantities of the International System of Units (SI) could be taken into account as a rule. Some readers will note that many special measuring methods and equipment known to them are not included in this book. I do hope, however, that this short-coming will show to have a positive effect, too. This book will show the reader how to find the basic quantities and units from the derived quantities and units, and the steps that are necessary to solve any kind of measuring task. (orig./RW) [de

  14. Removal performance and water quality analysis of paper machine white water in a full-scale wastewater treatment plant.

    Science.gov (United States)

    Shi, Shuai; Wang, Can; Fang, Shuai; Jia, Minghao; Li, Xiaoguang

    2017-06-01

    Paper machine white water is generally characterized as a high concentration of suspended solids and organic matters. A combined physicochemical-biological and filtration process was used in the study for removing pollutants in the wastewater. The removal efficiency of the pollutant in physicochemical and biological process was evaluated, respectively. Furthermore, advanced technology was used to analyse the water quality before and after the process treatment. Experimental results showed that the removal efficiency of suspend solids (SS) of the system was above 99%, while the physicochemical treatment in the forepart of the system had achieved about 97%. The removal efficiency of chemical oxygen demand (COD) and colour had the similar trend after physicochemical treatment and were corresponding to the proportion of suspended and the near-colloidal organic matter in the wastewater. After biological treatment, the removal efficiency of COD and colour achieved were about 97% and 90%, respectively. Furthermore, molecular weight (MW) distribution analysis showed that after treatment low MW molecules (analysis showed that most humic-like substances were effectively removed during the treatment. The analyses of gas chromatography/mass spectrometry showed that the composition of organic matter in the wastewater was not complicated. Methylsiloxanes were the typical organic components in the raw wastewater and most of them were removed after treatment.

  15. Development of Site-Specific Water Quality Criteria for the Arpa Harbor Wastewater Treatment Plant in Tipalao Bay, Guam

    Science.gov (United States)

    2016-07-01

    flats, estuaries, and coastal creeks. It is usually found within tidally influenced waters , but it may enter freshwater, ascending about 10...based on a dissolved metal concentration endpoint in the receiving body of water . In other words , the translator supports estimations of the fraction of...TECHNICAL REPORT 2068 July 2016 Development of Site-Specific Water Quality Criteria for the Arpa Harbor Wastewater Treatment Plant

  16. Corrosion control when using secondary treated municipal wastewater as alternative makeup water for cooling tower systems.

    Science.gov (United States)

    Hsieh, Ming-Kai; Li, Heng; Chien, Shih-Hsiang; Monnell, Jason D; Chowdhury, Indranil; Dzombak, David A; Vidic, Radisav D

    2010-12-01

    Secondary treated municipal wastewater is a promising alternative to fresh water as power plant cooling water system makeup water, especially in arid regions. Laboratory and field testing was conducted in this study to evaluate the corrosiveness of secondary treated municipal wastewater for various metals and metal alloys in cooling systems. Different corrosion control strategies were evaluated based on varied chemical treatment. Orthophosphate, which is abundant in secondary treated municipal wastewater, contributed to more than 80% precipitative removal of phosphorous-based corrosion inhibitors. Tolyltriazole worked effectively to reduce corrosion of copper (greater than 95% inhibition effectiveness). The corrosion rate of mild steel in the presence of free chlorine 1 mg/L (as Cl2) was approximately 50% higher than in the presence of monochloramine 1 mg/L (as Cl2), indicating that monochloramine is a less corrosive biocide than free chlorine. The scaling layers observed on the metal alloys contributed to corrosion inhibition, which could be seen by comparing the mild steel 21-day average corrosion rate with the last 5-day average corrosion rate, the latter being approximately 50% lower than the former.

  17. Quality and Trace Element Profile of Tunisian Olive Oils Obtained from Plants Irrigated with Treated Wastewater

    Directory of Open Access Journals (Sweden)

    Cinzia Benincasa

    2012-01-01

    Full Text Available In the present work the use of treated wastewater (TWW to irrigate olive plants was monitored. This type of water is characterized by high salinity and retains a substantial amount of trace elements, organic and metallic compounds that can be transferred into the soil and into the plants and fruits. In order to evaluate the impact of TWW on the overall quality of the oils, the time of contact of the olives with the soil has been taken into account. Multi-element data were obtained using ICP-MS. Nineteen elements (Li, B, Na, Mg, Al, K, Ca, Sc, Cr, Mn, Fe, Co, Ni, Cu, Zn, Sr, Mo, Ba and La were submitted for statistical analysis. Using analysis of variance, linear discriminant analysis and principal component analysis it was possible to differentiate between oils produced from different batches of olives whose plants received different types of water. Also, the results showed that there was correlation between the elemental and mineral composition of the water used to irrigate the olive plots and the elemental and mineral composition of the oils.

  18. Bacteriological quality of crops irrigated with wastewater in the Xochimilco plots, Mexico City, Mexico.

    Science.gov (United States)

    Rosas, I; Báez, A; Coutiño, M

    1984-05-01

    Xochimilco county plots (Mexico City), one of the most fertile agricultural areas in the Valley of Mexico, produce a large portion of the fresh vegetables consumed in the city. These plots are generally irrigated with domestic wastewater, and for this reason, it was deemed important to examine and evaluate the bacteriological quality of the water, soil, and vegetables from these plots that are harvested and marketed. The soils were also examined for the classical parameters such as nitrates, ammonia, etc., and organic matter and texture. The crops selected for this study were radishes, spinach, lettuce, parsley, and celery because they are usually consumed raw. The highest bacterial counts were encountered in leafy vegetables, i.e., spinach (8,700 for total coliform and 2,400 for fecal coliform) and lettuce (37,000 for total coliform and 3,600 for fecal coliform). Statistically significant differences in bacterial counts between rinsed and unrinsed edible portions of the crops were observed even in rinsed vegetables, and high densities of fecal coliform were detected, indicating that their consumption represents a potential health hazard. The total coliform values found in irrigation water ranged from 4 X 10(4) to 29 X 10(4), and for fecal coliform the values ranged from 5 X 10(2) to 30 X 10(2).

  19. Quality control in nuclear medicine

    International Nuclear Information System (INIS)

    Kostadinova, I.

    2007-01-01

    Nuclear medicine comprises diagnosis and therapy of the diseases with radiopharmaceuticals. The ambition of all specialists in our country is their activity to reach European standards. In this connection, a Commission for external audit was formed to evaluate the quality of work in the centers of nuclear medicine. This Commission create a long-lasting programme based on the objective European criteria and the national standard of nuclear medicine, having in mind to increase quality of the work and the expert evaluation of activity in every center. The program comprises measures for quality control of instrumentation, radiopharmaceuticals, performed investigations, obtained results and the whole organization from the receiving of the isotopes to the results of the patients. The ambition is most of the centers to fulfill the requirements. As a conclusion it could be said that not only the quality of everyday nuclear medicine work is enough to increase the prestige of the specialty. It is also necessary we to have understanding expert and financial support from corresponding institutions, incl. Ministry of health for a delivery of a new, contemporary instrumentation with new possibilities. Thus it would be possible Bulgarian patients to reach the high technology apparatuses for an early functional diagnosis of the diseases and optimal treatment, which possibility have the patients from the developed countries. (author)

  20. Quality control programme for radiotherapy

    International Nuclear Information System (INIS)

    Campos de Araujo, A.M.; Viegas, C.C.B.; Viamonte, A.M.

    2002-01-01

    A 3 years pilot programme started in January 2000 with 33 philanthropic cancer institutions that provides medical services to 60% of the patients from the national social security system. Brazil has today 161 radiotherapy services (144 operating with megavoltage equipment). These 33 institutions are distributed over 19 Brazilian states. The aim of this programme is: To create conditions to allow the participants to apply the radiotherapy with quality and efficacy; To promote up dating courses for the physicians, physicists and technicians of these 33 Institutions. With the following objectives: To recommend dosimetric and radiological protection procedures in order to guarantee the tumor prescribed dose and safe working conditions; To help in establishing and implementing these procedures. The main activities are: local quality control evaluations, postal TLD audits in reference conditions, postal TLD audits in off axis conditions and training. The local quality control program has already evaluated 22 institutions with 43 machines (25 Co-60 and 18 linear accelerators). In these visits we perform dosimetric, electrical, mechanical and safety tests. As foreseen, we found more problems among the old Co-60 machines i.e., field flatness, size, symmetry and relative output factors; lasers positioning system alignment; optical distance indicator; radiation and light field coincidence; optical and mechanical distance indicators agreement, than among the linear accelerators i.e., field flatness and size; lasers positioning system alignment; tray interlocking and wedge filter factors

  1. Family Control and Earnings Quality

    Directory of Open Access Journals (Sweden)

    Carolina Bona Sánchez

    2007-06-01

    Full Text Available El trabajo analiza la relación entre el control familiar y la calidad de la información contable en un contexto en el que el tradicional conflicto de agencia entre directivos y accionistas se desplaza a la divergencia de intereses entre accionistas controladores y minoritarios. Los resultados alcanzados muestran que, en comparación con las no familiares, las empresas de naturaleza familiar divulgan unos resultados de mayor calidad, tanto en términos de menores ajustes por devengo discrecionales como de mayor capacidad de los componentes actuales del resultado para predecir los cash flows futuros. Además, el aumento en los derechos de voto en manos de la familia controladora incrementa la calidad de los resultados contables. La evidencia obtenida se muestra consistente con la presencia de un efecto reputación/vinculación a largo plazo asociado a la empresa familiar. Adicionalmente, el trabajo refleja que a medida que disminuye la divergencia entre los derechos de voto y de cash flow en manos de la familia controladora, aumenta la calidad de la información contable.PALABRAS CLAVE: derechos de voto, divergencia, empresa familiar, calidad delresultado, reputación, beneficios privados.This work examines the relationship between family control and earnings quality in a context where the salient agency problem shifts away from the classical divergence between managers and shareholders to conflicts between the controlling owner and minority shareholders. The results reveal that, compared to non-family firms, family firms reveal higher earnings quality in terms of both lower discretionary accruals and greater predictability of future cash flows. They also show a positive relationship between the level of voting rights held by the controlling family and earnings quality. The evidence is consistent with the presence of a reputation/long-term involvement effect associated with the family firm. Moreover, the work reflects that, as the divergence

  2. Physicians, radiologists, and quality control

    International Nuclear Information System (INIS)

    Payne, W.F.

    1973-01-01

    Factors involved in quality control in medical x-ray examinations to achieve the least possible exposure to the patient are discussed. It would be hoped that film quality will remain in the position of paramount importance that it must in order to achieve the greatest amount of diagnostic information on each radiographic examination. At the same time, it is hoped that this can be done by further reducing the exposure of the patient to ionizing radiation by the methods that have been discussed; namely, education of the physician, radiologist, and technologist, modern protective equipment and departmental construction, efficient collimation whether automatic or manual, calibration and output measurement of the radiographic and fluoroscopic units, ongoing programs of education within each department of radiographic facility, film badge monitoring, education of and cooperation with the nonradiologic physician, and hopefully, more intensive programs by the National and State Bureaus and Departments of Radiological Health in education and encouragement to the medical community. (U.S.)

  3. Quality control of pesticide products

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2009-07-15

    In light of an established need for more efficient analytical procedures, this publication, which documents the findings of an IAEA coordinated research project (CRP) on “Quality Control of Pesticide Products”, simplifies the existing protocol for pesticide analysis while simultaneously upholding existing standards of quality. This publication includes both a report on the development work done in the CRP and a training manual for use by pesticide analysis laboratories. Based on peer reviewed and internationally recognized methods published by the Association of Analytical Communities (AOAC) and the Collaborative International Pesticides Analytical Council (CIPAC), this report provides laboratories with versatile tools to enhance the analysis of pesticide chemicals and to extend the scope of available analytical repertoires. Adoption of the proposed analytical methodologies promises to reduce laboratories’ use of solvents and the time spent on reconfiguration and set-up of analytical equipment.

  4. Quality control of pesticide products

    International Nuclear Information System (INIS)

    2009-07-01

    In light of an established need for more efficient analytical procedures, this publication, which documents the findings of an IAEA coordinated research project (CRP) on “Quality Control of Pesticide Products”, simplifies the existing protocol for pesticide analysis while simultaneously upholding existing standards of quality. This publication includes both a report on the development work done in the CRP and a training manual for use by pesticide analysis laboratories. Based on peer reviewed and internationally recognized methods published by the Association of Analytical Communities (AOAC) and the Collaborative International Pesticides Analytical Council (CIPAC), this report provides laboratories with versatile tools to enhance the analysis of pesticide chemicals and to extend the scope of available analytical repertoires. Adoption of the proposed analytical methodologies promises to reduce laboratories’ use of solvents and the time spent on reconfiguration and set-up of analytical equipment

  5. Water quality control system and water quality control method

    International Nuclear Information System (INIS)

    Itsumi, Sachio; Ichikawa, Nagayoshi; Uruma, Hiroshi; Yamada, Kazuya; Seki, Shuji

    1998-01-01

    In the water quality control system of the present invention, portions in contact with water comprise a metal material having a controlled content of iron or chromium, and the chromium content on the surface is increased than that of mother material in a state where compression stresses remain on the surface by mechanical polishing to form an uniform corrosion resistant coating film. In addition, equipments and/or pipelines to which a material controlling corrosion potential stably is applied on the surface are used. There are disposed a cleaning device made of a material less forming impurities, and detecting intrusion of impurities and removing them selectively depending on chemical species and/or a cleaning device for recovering drain from various kinds of equipment to feedwater, connecting a feedwater pipeline and a condensate pipeline and removing impurities and corrosion products. Then, water can be kept to neutral purified water, and the concentrations of oxygen and hydrogen in water are controlled within an optimum range to suppress occurrence of corrosion products. (N.H.)

  6. Determination of Water Quality Degradation Due to Industrial and Household Wastewater in the Galing River in Kuantan, Malaysia Using Ion Chromatograph and Water Quality Data

    Directory of Open Access Journals (Sweden)

    Daisuke Kozaki

    2017-04-01

    Full Text Available Water quality of the Galing River in Kuantan, Malaysia was examined to understand the anthropogenic environmental load in each administrative section, using water quality monitoring data and land use pattern. The National Physical Plan 2005 identified Kuantan as one of the country’s future growth centers, which has resulted in rapid development and environmental degradation in the past decade. Multiple water quality indexes used by the Department of Environment, Malaysia and concentrations of several ionic species were examined to assess the river’s water quality. The following inferences were drawn in this study: (1 Cl− and Na+ concentrations indicated that the basin area near the eastern urbanized area was subject to lesser human influence and lower environmental burden; (2 the Western side of the Galing River was subject to higher anthropogenic influence and indicated lower class levels of ammoniacal nitrogen, chemical oxygen demand, and dissolved oxygen, compared to the eastern side; (3 Class V or near class V pH values were obtained upstream at the western side of the Galing River in the industrial area; (4 Two types of environmental burden were identified in the western side of the Galing River, namely, inflow of industrial wastewater upstream on the western side and the effect of household wastewater or untreated raw sewage wastewater.

  7. Quality control in breast tomosynthesis

    International Nuclear Information System (INIS)

    Jakubiak, Rosangela Requi; Messias, Pricila Cordeiro; Santos, Marilia Fernanda; Urban, Linei Augusta B.D.

    2014-01-01

    In Brazil breast cancer is the most common and the leading cause of death among women, with estimated 57,000 new cases in 2014. The mammography (2D) plays an important role in the early detection of breast cancer, but in some cases can be difficult to detect malignant lesions due overlap of breast tissues. The Breast Digital Tomosynthesis (BDT: 3D) reduces the effects of overlap, providing improved characterization of mammographic findings. However, the dose may double as compared to the mammography. This study presents results of Contrast Ratio Noise tests (CRN) and quality image on a Siemens mammography equipment Mammomat Inspiration with tomosynthesis. The CRN was determined with plates Polymethylmethacrylate (PMMA) of 20 to 70 mm thickness and an aluminum plate of 10 mm 2 and 0.2 mm thickness. Image quality was assessed with the ACR Breast Simulator. In assessment of image quality, the detectability of fibers and masses was identical in 2D and 3D systems. Were visualized 4.5 fibers and 4 mass in both modes. In 2D mode groups have been identified 3.5 microcalcifications, and 3D were 3 groups. The Mean Glandular Dose for the simulator in 2D mode was 1.17 mGy and 2.35 mGy for the 3D mode. The result reinforces the importance of quality control in the process of obtaining the images and obtained in accordance CRN values, ensuring image quality and dose compatible in 2D and 3D processes

  8. Quality control in breast tomosynthesis

    Energy Technology Data Exchange (ETDEWEB)

    Jakubiak, R.R.; Messias, P.C.; Santos, M.F., E-mail: requi@utfpr.edu.br [Universidade Tecnologia Federal do Parana (UTFPR), Curitiba, PR (Brazil). Departamento Academico de Fisica; Urban, L.A.B.D., E-mail: lineiurban@hotmail.com [Diagnostico Avancado por Imagem, Curitiba, PR (Brazil)

    2015-07-01

    In Brazil, breast cancer is the most common and the leading cause of death among women, with estimated 57,000 new cases in 2014. The mammography (2D) plays an important role in the early detection of breast cancer, but in some cases can be difficult to detect malignant lesions due overlap of breast tissues. The Digital Breasts Tomosynthesis (DBT: 3D) reduces the effects of overlap, providing improved characterization of mammographic findings. However, the dose may double as compared with mammography. This study presents results of Contrast to Noise Ratio (CNR) and image quality evaluation on Siemens mammography equipment Mammomat Inspiration with tomosynthesis. The CNR was determined with Polymethylmethacrylate (PMMA) layers of 20 to 70 mm thick and an aluminum foils of 0,2 mm thickness and area of 10 mm². Image quality was assessed with the ACR Breast Simulator. In the evaluation of image quality, the detectability of fibers and masses was identical in 2D and 3D systems. Displaying fibers were 4,5 and 4 mass in both modes. In 2D mode were identified 3,5 microcalcifications groups, and 3D showed 3 groups. The Mean Glandular Dose (MGD) for the simulator in 2D mode was 1,17 mGy and 2,35 mGy for the 3D mode. The result reinforces the importance of quality control in the process of obtaining the images and obtained in accordance CNR values, ensuring image quality and compatible dose in 2D and 3D processes. (author)

  9. Quality control in breast tomosynthesis

    International Nuclear Information System (INIS)

    Jakubiak, R.R.; Messias, P.C.; Santos, M.F.

    2015-01-01

    In Brazil, breast cancer is the most common and the leading cause of death among women, with estimated 57,000 new cases in 2014. The mammography (2D) plays an important role in the early detection of breast cancer, but in some cases can be difficult to detect malignant lesions due overlap of breast tissues. The Digital Breasts Tomosynthesis (DBT: 3D) reduces the effects of overlap, providing improved characterization of mammographic findings. However, the dose may double as compared with mammography. This study presents results of Contrast to Noise Ratio (CNR) and image quality evaluation on Siemens mammography equipment Mammomat Inspiration with tomosynthesis. The CNR was determined with Polymethylmethacrylate (PMMA) layers of 20 to 70 mm thick and an aluminum foils of 0,2 mm thickness and area of 10 mm². Image quality was assessed with the ACR Breast Simulator. In the evaluation of image quality, the detectability of fibers and masses was identical in 2D and 3D systems. Displaying fibers were 4,5 and 4 mass in both modes. In 2D mode were identified 3,5 microcalcifications groups, and 3D showed 3 groups. The Mean Glandular Dose (MGD) for the simulator in 2D mode was 1,17 mGy and 2,35 mGy for the 3D mode. The result reinforces the importance of quality control in the process of obtaining the images and obtained in accordance CNR values, ensuring image quality and compatible dose in 2D and 3D processes. (author)

  10. 40 CFR 51.359 - Quality control.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 2 2010-07-01 2010-07-01 false Quality control. 51.359 Section 51.359....359 Quality control. Quality control measures shall insure that emission testing equipment is calibrated and maintained properly, and that inspection, calibration records, and control charts are...

  11. Novel application of bacteriophage for controlling foaming in wastewater treatment plant- an eco-friendly approach

    Science.gov (United States)

    Khairnar, Krishna; Chandekar, Rajshree; Nair, Aparna; Pal, Preeti; Paunikar, Waman N.

    2016-01-01

    ABSTRACT This addendum to “Novel application of bacteriophage for controlling foaming in wastewater treatment plant- an eco-friendly approach “ includes characteristics of the phages NOC1, NOC2 and NOC3 not discussed in the previous paper. The phage adsorption and host interaction properties, their sensitivity to pH and temperature are inferred. NOC2 is seen to be more temperature resistant while others are not. All the phages show pH sensitivity. There is a variance observed in the behavior of these phages. Also, applicability of the phage based system to large scale reactors is studied and discussed here. PMID:26890996

  12. New techniques to control salinity-wastewater reuse interactions in golf courses of the Mediterranean regions

    Science.gov (United States)

    Beltrao, J.; Costa, M.; Rosado, V.; Gamito, P.; Santos, R.; Khaydarova, V.

    2003-04-01

    Due to the lack water around the Mediterranean regions, potable water luxurious uses - as in golf courses - are increasingly contested. In order to solve this problem, non conventional water resources (effluent, gray, recycled, reclaimed, brackish), like treated wastewater, for irrigation gained increasing role in the planning and development of additional water supplies in golf courses. In most cases, the intense use of effluent for irrigation attracted public awareness in respect of contaminating pathogens and heavy metals. The contaminating effect of salinity in soil and underground water is very often neglected. The objective of this work is to present the conventional techniques to control salinity of treated wastewater and to present some results on new clean techniques to solve this problem, in the framework of the INCO-COPERNICUS project (no. IC-15CT98-0105) "Adaptation of Efficient Water Use Criteria in Marginal Regions of Europe and Middle Asia with Scarce Sources Subject to Environmental Control, Climate Change and Socio-Economic Development" and of the INCO-DC project (no. IC18-CT98-0266) "Control of Salination and Combating Desertification Effects in the Mediterranean Region. Phase II". Saline water is the most common irrigation water in arid climates. Moreover, for each region treated wastewater is always more saline than tap water, and therefore, when treated wastewater is reused in golf courses, more salinity problems occur. Conventional techniques to combat the salination process in golf courses can be characterized by four generations: 1) Problem of root zone salination by soil leaching - two options can occur - when there is an impermeable layer, salts will be concentrated above this layer; on the other hand, when there is no impermeable layer, aquifers contamination can be observed; 2) Use of subsurface trickle irrigation - economy of water, and therefore less additional salts; however the problem of groundwater contamination due to natural rain

  13. 2. Product quality control and assurance system

    International Nuclear Information System (INIS)

    1990-01-01

    Product quality control and assurance are dealt with in relation to reliability in nuclear power engineering. The topics treated include product quality control in nuclear power engineering, product quality assurance of nuclear power plant equipment, quality assurance programs, classification of selected nuclear power equipment, and standards relating to quality control and assurance and to nuclear power engineering. Particular attention is paid to Czechoslovak and CMEA standards. (P.A.). 2 figs., 1 tab., 12 refs

  14. Internal quality control: best practice.

    Science.gov (United States)

    Kinns, Helen; Pitkin, Sarah; Housley, David; Freedman, Danielle B

    2013-12-01

    There is a wide variation in laboratory practice with regard to implementation and review of internal quality control (IQC). A poor approach can lead to a spectrum of scenarios from validation of incorrect patient results to over investigation of falsely rejected analytical runs. This article will provide a practical approach for the routine clinical biochemistry laboratory to introduce an efficient quality control system that will optimise error detection and reduce the rate of false rejection. Each stage of the IQC system is considered, from selection of IQC material to selection of IQC rules, and finally the appropriate action to follow when a rejection signal has been obtained. The main objective of IQC is to ensure day-to-day consistency of an analytical process and thus help to determine whether patient results are reliable enough to be released. The required quality and assay performance varies between analytes as does the definition of a clinically significant error. Unfortunately many laboratories currently decide what is clinically significant at the troubleshooting stage. Assay-specific IQC systems will reduce the number of inappropriate sample-run rejections compared with the blanket use of one IQC rule. In practice, only three or four different IQC rules are required for the whole of the routine biochemistry repertoire as assays are assigned into groups based on performance. The tools to categorise performance and assign IQC rules based on that performance are presented. Although significant investment of time and education is required prior to implementation, laboratories have shown that such systems achieve considerable reductions in cost and labour.

  15. Effects of fertigation with purified urban wastewater on soil and pepper plant (Capsicum annuum L.) production, fruit quality and pollutant contents

    Energy Technology Data Exchange (ETDEWEB)

    Garcia-Delgado, C.; Eymar, E.; Contreras, J. I.; Segura, M. L.

    2012-11-01

    The effects, in greenhouse conditions, of Purified Urban Wastewater (PW) from Almeria (Spain), in the fertigation of pepper (Capsicum annuum L.) on sandy mulch soil, were evaluated. Primary, secondary (active sludges) and tertiary (Chlorination + ozonation) purification treatments were applied to wastewater. Irrigation treatments applied were PW, natural Ground Water (GW), Fertilizer PW (FPW) and Fertilizer GW (FGW). The vegetal biomass, yield and fruit quality were controlled. Heavy metals (Cr, Cd, Pb, Ni, Mn, Cu and Zn), arsenic (As) and Polycyclic Aromatic Hydrocarbons (PAH) in water, soil, leaf, and fruit were analysed. The PW presented heavy metal, As and PAH contents acceptable for its use in drip irrigation. In the soil, fertigated with PW, the concentration of heavy metals and As did not increase, whilst the PAH concentration decreased. The PW treatment supplied enough nutrients to obtain yield and fruit quality equal to that of GW with fertilization. A significant saving on N, P and K fertilizers (37%, 66% and 12% respectively) was achieved by using PW. The Cd, Pb and As contents of the fruit did not show risk for human consumption. The total PAH concentrations in the fruit were low, the highest of which was phenathrene, with no carcinogenic signification. (Author) 39 refs.

  16. Performance evaluation of a smart buffer control at a wastewater treatment plant.

    Science.gov (United States)

    van Daal-Rombouts, P; Benedetti, L; de Jonge, J; Weijers, S; Langeveld, J

    2017-11-15

    Real time control (RTC) is increasingly seen as a viable method to optimise the functioning of wastewater systems. Model exercises and case studies reported in literature claim a positive impact of RTC based on results without uncertainty analysis and flawed evaluation periods. This paper describes two integrated RTC strategies at the wastewater treatment plant (WWTP) Eindhoven, the Netherlands, that aim to improve the use of the available tanks at the WWTP and storage in the contributing catchments to reduce the impact on the receiving water. For the first time it is demonstrated that a significant improvement can be achieved through the application of RTC in practice. The Storm Tank Control is evaluated based on measurements and reduces the number of storm water settling tank discharges by 44% and the discharged volume by an estimated 33%, decreasing dissolved oxygen depletion in the river. The Primary Clarifier Control is evaluated based on model simulations. The maximum event NH4 concentration in the effluent reduced on average 19% for large events, while the load reduced 20%. For all 31 events the reductions are 11 and 4% respectively. Reductions are significant taking uncertainties into account, while using representative evaluation periods. Copyright © 2017 Elsevier Ltd. All rights reserved.

  17. [Source identification of toxic wastewaters in a petrochemical industrial park].

    Science.gov (United States)

    Yang, Qian; Yu, Yin; Zhou, Yue-Xi; Chen, Xue-Min; Fu, Xiao-Yong; Wang, Miao

    2014-12-01

    Petrochemical wastewaters have toxic impacts on the microorganisms in biotreatment processes, which are prone to cause deterioration of effluent quality of the wastewater treatment plants. In this study, the inhibition effects of activated sludge's oxygen consumption were tested to evaluate the toxicity of production wastewaters in a petrochemical industrial park. The evaluation covered the wastewaters from not only different production units in the park, but also different production nodes in each unit. No direct correlation was observed between the toxicity effects and the organic contents, suggesting that the toxic properties of the effluents could not be predicted by the organic contents. In view of the variation of activated sludge sensitivity among different tests, the toxicity data were standardized according to the concentration-effect relationships of the standard toxic substance 3, 5-dichlorophenol on each day, in order to improve the comparability among the toxicity data. Furthermore, the Quality Emission Load (QEL) of corresponding standard toxic substance was calculated by multiplying the corresponding 3, 5-dichlorophenol concentration and the wastewater flow quantity, to indicate the toxicity emission contribution of each wastewater to the wastewater treatment plant. According to the rank list of the toxicity contribution of wastewater from different units and nodes, the sources of toxic wastewater in the petrochemical industrial park were clearly identified. This study provides effective guidance for source control of wastewater toxicity in the large industrial park.

  18. Monitoring and control of UV and UV-TiO2 disinfections for municipal wastewater reclamation using artificial neural networks

    International Nuclear Information System (INIS)

    Lin, Chuang-Hung; Yu, Ruey-Fang; Cheng, Wen-Po; Liu, Chun-Ru

    2012-01-01

    Highlights: ► ANN models can effectively control both UV and UV-TiO 2 disinfections for wastewater reuse. ► Comparing to UV disinfection, UV-TiO 2 disinfection can save 13.2–15.7% of UV dosage and capacity. ► SS decreases disinfection efficiency when UV doses were 2 . - Abstract: The use of ultraviolet (UV) irradiation as a physical wastewater disinfection has increased in recent years, especially for wastewater reuse. The UV-TiO 2 can generate OH radicals, which is highly effective to inactivate microorganisms in wastewater disinfection. However, both UV and UV-TiO 2 disinfections create multiple physical, chemical, and bio-chemical phenomena that affect their germicidal efficiency. It is difficult to build a precise control model using existing mathematic models. This study applies artificial neural network (ANN) models to control UV and UV-TiO 2 disinfections. Experimental results indicate that the ANN models, which precisely generate relationships among multiple monitored parameters, total coliform counts in influent and effluent, and UV doses, can be used as control models for UV and UV-TiO 2 disinfections. A novel ANN control strategy is applied to control UV and UV-TiO 2 disinfection processes to meet three total coliform count limits for three wastewater reuse purposes. The proposed controlled strategy effectively controls UV and UV-TiO 2 disinfection, resulting in acceptable total coliform counts in effluent for the three wastewater reuse purposes. The required UV doses for UV-TiO 2 disinfection were lower than those for UV disinfection, resulting in energy saving and capacity reduction of 13.2–15.7%.

  19. 14 CFR 21.139 - Quality control.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Quality control. 21.139 Section 21.139... PROCEDURES FOR PRODUCTS AND PARTS Production Certificates § 21.139 Quality control. The applicant must show that he has established and can maintain a quality control system for any product, for which he...

  20. Quality and reliability control on assemblies

    International Nuclear Information System (INIS)

    Mueller, H.

    1976-01-01

    Taking as an example electronic assemblies in printed circuit board engineering, quality control during manufacture is dealt with. After giving a survey of four phases of quality and reliability control, some specific methods of quality control are dealt with by means of a flowchart, and by some examples the necessity and the success of these measures are shown. (RW) [de

  1. 7 CFR 930.44 - Quality control.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 8 2010-01-01 2010-01-01 false Quality control. 930.44 Section 930.44 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Marketing Agreements... Control § 930.44 Quality control. (a) Quality standards. The Board may establish, with the approval of the...

  2. 33 CFR 385.21 - Quality control.

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 3 2010-07-01 2010-07-01 false Quality control. 385.21 Section... Processes § 385.21 Quality control. (a) The Corps of Engineers and the non-Federal sponsor shall prepare a quality control plan, in accordance with applicable Corps of Engineers regulations, for each product that...

  3. 7 CFR 981.42 - Quality control.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 8 2010-01-01 2010-01-01 false Quality control. 981.42 Section 981.42 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Marketing Agreements... Regulating Handling Quality Control § 981.42 Quality control. (a) Incoming. Except as provided in this...

  4. Association between product quality control and process quality control of bulk milk

    NARCIS (Netherlands)

    Velthuis, A.; Asseldonk, van M.A.P.M.

    2010-01-01

    Assessment of dairy-milk quality is based on product quality control (testing bulk-milk samples) and process quality control (auditing dairy farms). It is unknown whether process control improves product quality. To quantify possible association between product control and process control a

  5. Groundwater-quality data for a treated-wastewater plume near the Massachusetts Military Reservation, Ashumet Valley, Cape Cod, Massachusetts, 2006-08

    Science.gov (United States)

    Savoie, Jennifer G.; LeBlanc, Denis R.; Fairchild, Gillian M.; Smith, Richard L.; Kent, Douglas B.; Barber, Larry B.; Repert, Deborah A.; Hart, Charles P.; Keefe, Steffanie H.; Parsons, Luke A.

    2012-01-01

    A plume of contaminated groundwater extends from former disposal beds at the Massachusetts Military Reservation's wastewater-treatment plant toward Ashumet Pond, coastal ponds, and Vineyard Sound, Cape Cod, Massachusetts. Treated sewage-derived wastewater was discharged to the rapid-infiltration beds for nearly 60 years before the disposal site was moved to a different location in December 1995. Water-quality samples were collected from monitoring wells, multilevel samplers, and profile borings to characterize the nature and extent of the contaminated groundwater and to observe the water-quality changes after the wastewater disposal ceased. Data are presented here for water samples collected in 2007 from 394 wells (at 121 well-cluster locations) and 780 multilevel-sampler ports (at 42 locations) and in 2006-08 at 306 depth intervals in profile borings (at 20 locations) in and near the treated-wastewater plume. Analyses of these water samples for field parameters (specific conductance, pH, dissolved oxygen and phosphate concentrations, and alkalinity); absorbance of ultraviolet/visible light; and concentrations of nitrous oxide, dissolved organic carbon, methylene blue active substances, selected anions and nutrients, including nitrate and ammonium, and selected inorganic solutes, including cations, anions, and minor elements, are presented in tabular format. The natural restoration of the sand and gravel aquifer after removal of the treated-wastewater source, along with interpretations of the water quality in the treated-wastewater plume, have been documented in several published reports that are listed in the references.

  6. Quality control analysis at the hospital

    International Nuclear Information System (INIS)

    Kristensen, K.

    1979-01-01

    Quality control analysis is an integral part of quality assurance. In a system as with radiopharmaceuticals where part of the finishing of the product takes place at individual hospitals, the need for quality control analysis at the hospital can be discussed. Data are presented that stresses the importance of quality control by the manufacturer as a basis for limitation of such work at hospitals. A simplified programme is proposed

  7. Bacteriological Quality of Tilapia Fish from Treated Wastewater in Peri-Urban Areas, Morogoro, Tanzania

    DEFF Research Database (Denmark)

    Mhongole, OJ; Mdegela, RH; Kusiluka, LJM

    2016-01-01

    the inlet to outlet of Mzumbe wastewater treatment pond, there was a significant reduction (pquality for human consumption based......The aim of this study was to assess faecal bacterial contamination in tilapia fish from wastewater treatment ponds at Mzumbe and in pristine water in Mindu dam. Tilapia fish (fish flesh and fish intestines) and water samples were analysed for Escherichia coli and total plate count....... The concentration of E. coli in fish intestines ranged from about 1 - 3.5 log cfu/g and water in Mindu dam ranged from 0 to 15 cfu/mL. From...

  8. Quality control guarantees the safety of radiotherapy

    International Nuclear Information System (INIS)

    Aaltonen, P.

    1994-01-01

    While radiotherapy equipment has seen some decisive improvements in the last few decades, the technology has also become more complicated. The advanced equipment produces increasingly good treatment results, but the condition of the equipment must be controlled efficiently so as to eliminate any defects that might jeopardise patient safety. The quality assurance measures that are taken to show that certain equipment functions as required are known as quality control. The advanced equipment and stricter requirements set for the precision of radiotherapy have meant that more attention must be paid to quality control. The present radiation legislation stipulates that radiotherapy equipment must undergo regular quality control. The implementation of the quality control is supervised by the Finnish Centre for Radiation and Nuclear Safety (STUK). Hospitals carry out quality control in accordance with a programme approved by STUK, and STUK inspectors periodically visit hospitals to check the results of quality control. (orig.)

  9. Radiopharmaceutical quality control-Pragmatic approach

    International Nuclear Information System (INIS)

    Barbier, Y.

    1994-01-01

    The quality control must be considered in a practical manner. The radiopharmaceuticals are drugs. They must satisfy the quality assurance control. These products are then conform to Pharmacopeia. But sometimes the user must control some data especially radiochemical purity and pH value. On all the administered solutions four controls are compulsory: radionuclide identity, administered radioactivity, organoleptic character and pH

  10. Fate of antibiotic resistant bacteria and genes during wastewater chlorination: implication for antibiotic resistance control.

    Directory of Open Access Journals (Sweden)

    Qing-Bin Yuan

    Full Text Available This study investigated fates of nine antibiotic-resistant bacteria as well as two series of antibiotic resistance genes in wastewater treated by various doses of chlorine (0, 15, 30, 60, 150 and 300 mg Cl2 min/L. The results indicated that chlorination was effective in inactivating antibiotic-resistant bacteria. Most bacteria were inactivated completely at the lowest dose (15 mg Cl2 min/L. By comparison, sulfadiazine- and erythromycin-resistant bacteria exhibited tolerance to low chlorine dose (up to 60 mg Cl2 min/L. However, quantitative real-time PCRs revealed that chlorination decreased limited erythromycin or tetracycline resistance genes, with the removal levels of overall erythromycin and tetracycline resistance genes at 0.42 ± 0.12 log and 0.10 ± 0.02 log, respectively. About 40% of erythromycin-resistance genes and 80% of tetracycline resistance genes could not be removed by chlorination. Chlorination was considered not effective in controlling antimicrobial resistance. More concern needs to be paid to the potential risk of antibiotic resistance genes in the wastewater after chlorination.

  11. Including Life Cycle Assessment for decision-making in controlling wastewater nutrient removal systems

    DEFF Research Database (Denmark)

    Corominas, Lluís; Larsen, Henrik Fred; Flores-Alsina, Xavier

    2013-01-01

    This paper focuses on the use of Life Cycle Assessment (LCA) to evaluate the performance of seventeen control strategies in wastewater treatment plants (WWTPs). It tackles the importance of using site-specific factors for nutrient enrichment when decision-makers have to select best operating....../or energy savings present an environmental benefit for N&P and P-deficient systems. This is not the case when addressing N-deficient systems for which the use of chemicals (even for improving N removal efficiencies) is not always beneficial for the environment. A sensitivity analysis on using weighting...... of the impact categories is conducted to assess how value choices (policy decisions) may affect the management of WWTPs. For the scenarios with only N-limitation, the LCA-based ranking of the control strategies is sensitive to the choice of weighting factors, whereas this is not the case for N&P or P...

  12. Expert database system for quality control

    Science.gov (United States)

    Wang, Anne J.; Li, Zhi-Cheng

    1993-09-01

    There are more competitors today. Markets are not homogeneous they are fragmented into increasingly focused niches requiring greater flexibility in the product mix shorter manufacturing production runs and above allhigher quality. In this paper the author identified a real-time expert system as a way to improve plantwide quality management. The quality control expert database system (QCEDS) by integrating knowledge of experts in operations quality management and computer systems use all information relevant to quality managementfacts as well as rulesto determine if a product meets quality standards. Keywords: expert system quality control data base

  13. Quality control of activity detectors

    International Nuclear Information System (INIS)

    Surma, M.J.

    2002-01-01

    The conditions decided on radiometric measurements quality as geometry, background, calibration etc. have been described. The testing methods for achieving high quality of radioactivity measurements using nuclear medicine instruments have been recommended

  14. 30 CFR 74.6 - Quality control.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Quality control. 74.6 Section 74.6 Mineral... of the CMDPSU will be maintained in production through adequate quality control procedures, MSHA and... DUST SAMPLING DEVICES Approval Requirements for Coal Mine Dust Personal Sampler Unit § 74.6 Quality...

  15. Recycling of treated domestic effluent from an on-site wastewater treatment system for hydroponics.

    Science.gov (United States)

    Oyama, N; Nair, J; Ho, G E

    2005-01-01

    An alternative method to conserve water and produce crops in arid regions is through hydroponics. Application of treated wastewater for hydroponics will help in stripping off nutrients from wastewater, maximising reuse through reduced evaporation losses, increasing control on quality of water and reducing risk of pathogen contamination. This study focuses on the efficiency of treated wastewater from an on-site aerobic wastewater treatment unit. The experiment aimed to investigate 1) nutrient reduction 2) microbial reduction and 3) growth rate of plants fed on wastewater compared to a commercial hydroponics medium. The study revealed that the chemical and microbial quality of wastewater after hydroponics was safe and satisfactory for irrigation and plant growth rate in wastewater hydroponics was similar to those grown in a commercial medium.

  16. Employee quality, monitoring environment and internal control

    OpenAIRE

    Chunli Liu; Bin Lin; Wei Shu

    2017-01-01

    We investigate the effect of internal control employees (ICEs) on internal control quality. Using special survey data from Chinese listed firms, we find that ICE quality has a significant positive influence on internal control quality. We examine the effect of monitoring on this result and find that the effect is more pronounced for firms with strict monitoring environments, especially when the firms implement the Chinese internal control regulation system (CSOX), have higher institutional ow...

  17. One Layer Nonlinear Economic Closed-Loop Generalized Predictive Control for a Wastewater Treatment Plant

    Directory of Open Access Journals (Sweden)

    Hicham El bahja

    2018-04-01

    Full Text Available The main scope of this paper is the proposal of a new single layer Nonlinear Economic Closed-Loop Generalized Predictive Control (NECLGPC as an efficient advanced control technique for improving economics in the operation of nonlinear plants. Instead of the classic dual-mode MPC (model predictive controller schemes, where the terminal control law defined in the terminal region is obtained offline solving a linear quadratic regulator problem, here the terminal control law in the NECLGPC is determined online by an unconstrained Nonlinear Generalized Predictive Control (NGPC. In order to make the optimization problem more tractable two considerations have been made in the present work. Firstly, the prediction model consisting of a nonlinear phenomenological model of the plant is expressed with linear structure and state dependent matrices. Secondly, instead of including the nonlinear economic cost in the objective function, an approximation of the reduced gradient of the economic function is used. These assumptions allow us to design an economic unconstrained nonlinear GPC analytically and to state the NECLGPC allow for the design of an economic problem as a QP (Quadratic Programing problem each sampling time. Four controllers based on GPC that differ in designs and structures are compared with the proposed control technique in terms of process performance and energy costs. Particularly, the methodology is implemented in the N-Removal process of a Wastewater Treatment Plant (WWTP and the results prove the efficiency of the method and that it can be used profitably in practical cases.

  18. Impact of winery wastewater irrigation on soil, grape nutrition, and grape and wine quality

    Science.gov (United States)

    Winery wastewater (WW) reuse has the potential to provide more sustainable vineyard irrigation. This study investigated the effects of WW irrigation on grape and wine chemical composition and sensory attributes in vineyards in Napa and Sonoma Counties. The life cycle of the grape/wine production was...

  19. Problems of quality assurance and quality control in diagnostic radiology

    International Nuclear Information System (INIS)

    Angerstein, W.

    1986-01-01

    Topical problems of quality assurance and quality control in diagnostic radiology are discussed and possible solutions are shown. Complex units are differentiated with reference to physicians, technicians, organization of labour, methods of examination and indication. Quality control of radiologic imaging systems should involve three stages: (1) simple tests carried out by radiologic technicians, (2) measurements by service technicians, (3) testing of products by the manufacturer and independent governmental or health service test agencies. (author)

  20. Quality control in tile production

    Science.gov (United States)

    Kalviainen, Heikki A.; Kukkonen, Saku; Hyvarinen, Timo S.; Parkkinen, Jussi P. S.

    1998-10-01

    This work studies visual quality control in ceramics industry. In tile manufacturing, it is important that in each set of tiles, every single tile looks similar. For example, the tiles should have similar color and texture. Our goal is to design a machine vision system that can estimate the sufficient similarity or same appearance to the human eye. Currently, the estimation is usually done by human vision. Differing from other approaches our aim is to use accurate spectral representation of color, and we are comparing spectral features to the RGB color features. A laboratory system for color measurement is built. Experimentations with five classes of brown tiles are presented. We use chromaticity RGB features and several spectral features for classification with the k-NN classifier and with a neural network, called Self-Organizing Map. We can classify many of the tiles but there are several problems that need further investigations: larger training and test sets are needed, illuminations effects must be studied further, and more suitable spectral features are needed with more sophisticated classifiers. It is also interesting to develop further the neural approach.

  1. Wastewater reuse

    Directory of Open Access Journals (Sweden)

    Milan R. Radosavljević

    2013-12-01

    Full Text Available Water scarcity and water pollution are some of the crucial issues that must be addressed within local and global perspectives. One of the ways to reduce the impact of water scarcity  and to minimizine water pollution is to expand water and wastewater reuse. The local conditions including regulations, institutions, financial mechanisms, availability of local technology and stakeholder participation have a great influence on the decisions for wastewater reuse. The increasing awareness of food safety and the influence of the countries which import food are influencing policy makers and agriculturists to improve the standards of wastewater reuse in agriculture. The environmental awareness of consumers has been putting pressure on the producers (industries to opt for environmentally sound technologies including those which conserve water and reduce the level of pollution. It may be observed that we have to move forwards to implement strategies and plans for wastewater reuse. However, their success and sustainability will depend on political will, public awareness and active support from national and international agencies to create favorable    environment for the promotion of environmentally sustainable technologies. Wastewater treatment has a long history, especially in agriculture, but also in industry and households. Poor quality of wastewater can pose a significant risk to the health of farmers and users of agricultural products. The World Health Organization (WHO is working on a project for the reuse of wastewater in agriculture. To reduce effects of human activities to the minimum, it is necessary to provide such technical and technological solutions that would on the one hand ensure complying with  the existing regulations and legislation, and on the other hand provide economically viable systems as seen through investments and operating costs. The use of wastewater The practice of using wastewater varies from country to country. Its

  2. Shipping/Receiving and Quality Control

    Data.gov (United States)

    Federal Laboratory Consortium — Shipping receiving, quality control, large and precise inspection and CMM machines. Coordinate Measuring Machines, including "scanning" probes, optical comparators,...

  3. Quality control of static irradiation processing products

    International Nuclear Information System (INIS)

    Bao Jianzhong; Chen Xiulan; Cao Hong; Zhai Jianqing

    2002-01-01

    Based on the irradiation processing practice of the nuclear technique application laboratory of Yangzhou Institute of Agricultural Science, the quality control of irradiation processing products is discussed

  4. Formal Design and Analysis of a Wastewater Treatment Control System based on Petrinet

    Directory of Open Access Journals (Sweden)

    Seno D. Panjaitan

    2012-04-01

    Full Text Available This paper proposes a new control design approach for industrial wastewater treatment where its logic control is verifiable. In this research, a treatment control design in a lab-scale was controlled by a microcontroller circuit. The developed system combined anaerobic digestion, aeration and filtration process. Its logic control algorithm was designed by using Signal Interpreted Petri Net. In the logic verification, six analysis properties were satisfied: conflict free (logical process had no conflict behavior, termination (the process could be terminated from any state, non-contradictory outputs, live (any process state could always be reached from other state, deadlock-free, and reversible (the process could always back to initial condition. In the design evaluation, the average value of transparency metrics was 0.984 close to 1 as the best value. The system performance was evaluated by pollutant removal efficiency. The highest removal efficiencies were obtained when each anaerobic and aeration treatment were performed for three days respectively and followed by filtration. Within this condition, the system obtained average removal efficiency 91.7% of Chemical Oxygen Demand and 95.4% of Total Suspended Solids. In terms of electricity consumption, the system needed only 1,857.6 Watt-hour for a batch treatment process.

  5. Establishment for quality control of experimental animal

    International Nuclear Information System (INIS)

    Kim, Tae Hwan; Kim, Soo Kwan; Kim, Tae Kyoung

    1999-06-01

    Until now, because we have imported experimental animal from foreign experimental animal corporation, we could have saved money by establishing the quality control of animal in barrier system. In order to improve the quality of animal experiment and efficiency of biomedical study, it is indispensable to control many factors that effect in the experiment. Therefore, it is essential to organize the system of laboratory animal care for enhancing reliability and revivability of experimental results. The purpose of the present investigation was to establish the quality control system of experimental animals that we can provide good quality animals according to the experimental condition of each investigator although the exact quality control system to estimate the infection of bacteria and virus easily remains ill-defined yet. Accordingly, we established the useful quality control system for microbiologic monitoring and environmental monitoring to protect experimental animal from harmful bacteria and virus

  6. Establishment for quality control of experimental animal

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Tae Hwan; Kim, Soo Kwan; Kim, Tae Kyoung

    1999-06-01

    Until now, because we have imported experimental animal from foreign experimental animal corporation, we could have saved money by establishing the quality control of animal in barrier system. In order to improve the quality of animal experiment and efficiency of biomedical study, it is indispensable to control many factors that effect in the experiment. Therefore, it is essential to organize the system of laboratory animal care for enhancing reliability and revivability of experimental results. The purpose of the present investigation was to establish the quality control system of experimental animals that we can provide good quality animals according to the experimental condition of each investigator although the exact quality control system to estimate the infection of bacteria and virus easily remains ill-defined yet. Accordingly, we established the useful quality control system for microbiologic monitoring and environmental monitoring to protect experimental animal from harmful bacteria and virus.

  7. Water quality, seasonality, and trajectory of an aquaculture-wastewater plume in the Red Sea

    KAUST Repository

    Hozumi, Aya; Hong, Pei-Ying; Kaartvedt, S; Rø stad, Anders; Jones, Burton

    2017-01-01

    As aquaculture activity increases globally, understanding water mass characteristics of the aquaculture-wastewater plume, its nutrients, and its organic matter load and spatial distribution in the coastal recipient, is critical to develop a more sustainable aquaculture operation and to improve coastal management. We examined wastewater (estimated 42-48 m3 s-1) discharged from the largest aquaculture facility in the Red Sea and surveyed the area around the aquaculture outfall to characterize the biogeochemical properties of the wastewater plume and its spatial distribution. In addition, we assessed its associated microbial community structure. The plume was characterized by elevated levels of salinity, density, and turbidity, and traveled along paths determined by the bathymetry to form a dense, 1-3 m thick layer above the seafloor. The effluent was observed at least 3.8 km from the outfall throughout the year, but up to 8 km in early autumn. The total nitrogen concentration in the plume was more than 4 times higher than in surface waters 1.4 km from the outfall. High-throughput sequencing data revealed that bacterial and cyanobacterial communities significantly differed, and flow cytometry results showed that total cell counts were significantly higher at the outfall. Arcobacter, a genus associated with opportunistic pathogenic species (e.g. A. butzleri), was more abundant, while Prochlorococcus sp. was significantly less abundant at the outfall. This dense, bottom-flowing plume may have a detrimental impact on benthic and demersal communities.

  8. Water quality, seasonality, and trajectory of an aquaculture-wastewater plume in the Red Sea

    KAUST Repository

    Hozumi, Aya

    2017-12-28

    As aquaculture activity increases globally, understanding water mass characteristics of the aquaculture-wastewater plume, its nutrients, and its organic matter load and spatial distribution in the coastal recipient, is critical to develop a more sustainable aquaculture operation and to improve coastal management. We examined wastewater (estimated 42-48 m3 s-1) discharged from the largest aquaculture facility in the Red Sea and surveyed the area around the aquaculture outfall to characterize the biogeochemical properties of the wastewater plume and its spatial distribution. In addition, we assessed its associated microbial community structure. The plume was characterized by elevated levels of salinity, density, and turbidity, and traveled along paths determined by the bathymetry to form a dense, 1-3 m thick layer above the seafloor. The effluent was observed at least 3.8 km from the outfall throughout the year, but up to 8 km in early autumn. The total nitrogen concentration in the plume was more than 4 times higher than in surface waters 1.4 km from the outfall. High-throughput sequencing data revealed that bacterial and cyanobacterial communities significantly differed, and flow cytometry results showed that total cell counts were significantly higher at the outfall. Arcobacter, a genus associated with opportunistic pathogenic species (e.g. A. butzleri), was more abundant, while Prochlorococcus sp. was significantly less abundant at the outfall. This dense, bottom-flowing plume may have a detrimental impact on benthic and demersal communities.

  9. Quality Control in Production Processes

    Directory of Open Access Journals (Sweden)

    Prístavka Miroslav

    2016-09-01

    Full Text Available The tools for quality management are used for quality improvement throughout the whole Europe and developed countries. Simple statistics are considered one of the most basic methods. The goal was to apply the simple statistical methods to practice and to solve problems by using them. Selected methods are used for processing the list of internal discrepancies within the organization, and for identification of the root cause of the problem and its appropriate solution. Seven basic quality tools are simple graphical tools, but very effective in solving problems related to quality. They are called essential because they are suitable for people with at least basic knowledge in statistics; therefore, they can be used to solve the vast majority of problems.

  10. Quality control of mammographic systems

    International Nuclear Information System (INIS)

    Espana Lopez, M. L.

    2001-01-01

    High quality in mammography is a difficult objective to achieve, that is the reason for what efforts are made in order to improve equipment, to offer good combinations screen-film, and professional staff dedicated to this technique [es

  11. Employee quality, monitoring environment and internal control

    Directory of Open Access Journals (Sweden)

    Chunli Liu

    2017-03-01

    Full Text Available We investigate the effect of internal control employees (ICEs on internal control quality. Using special survey data from Chinese listed firms, we find that ICE quality has a significant positive influence on internal control quality. We examine the effect of monitoring on this result and find that the effect is more pronounced for firms with strict monitoring environments, especially when the firms implement the Chinese internal control regulation system (CSOX, have higher institutional ownership or attach greater importance to internal control. Our findings suggest that ICEs play an important role in the design and implementation of internal control systems. Our study should be of interest to both top managers who wish to improve corporate internal control quality and regulators who wish to understand the mechanisms of internal control monitoring.

  12. Quality control education in the community college

    Science.gov (United States)

    Greene, J. Griffen; Wilson, Steve

    1966-01-01

    This paper describes the Quality Control Program at Daytona Beach Junior College, including course descriptions. The program in quality control required communication between the college and the American Society for Quality Control (ASQC). The college has machinery established for certification of the learning process, and the society has the source of teachers who are competent in the technical field and who are the employers of the educational products. The associate degree for quality control does not have a fixed program, which can serve all needs, any more than all engineering degrees have identical programs. The main ideas which would be common to all quality control programs are the concept of economic control of a repetitive process and the concept of developing individual potentialities into individuals who are needed and productive.

  13. The controlled ecological life support system Antarctic analog project: Analysis of wastewater from the South Pole Station, Antarctica, volume 1

    Science.gov (United States)

    Flynn, Michael T.; Bubenheim, David L.; Straight, Christian L.; Belisle, Warren

    1994-01-01

    The Controlled Ecological Life Support system (CELSS) Antarctic Analog Project (CAAP) is a joint National Science Foundation (NSF) and NASA project for the development, deployment and operation of CELSS technologies at the Amundsen-Scott South Pole Station. NASA goals are operational testing of CELSS technologies and the conduct of scientific studies to facilitate technology selection and system design. The NSF goals are that the food production, water purification, and waste treatment capabilities which will be provided by CAAP will improve the quality of life for the South Pole inhabitants, reduce logistics dependence, and minimize environmental impacts associated with human presence on the polar plateau. This report presents an analysis of wastewater samples taken from the Amundsen-Scott South Pole Station, Antarctica. The purpose of the work is to develop a quantitative understanding of the characteristics of domestic sewage streams at the South Pole Station. This information will contribute to the design of a proposed plant growth/waste treatment system which is part of the CELSS Antarctic Analog Project (CAAP).

  14. Control of Sewer systems and Wastewater treatment plants using pollutant concentration profiles

    DEFF Research Database (Denmark)

    Bechmann, Henrik; Nielsen, Marinus K.; Madsen, Henrik

    1998-01-01

    On-line measurements of pollutants in the wastewater combined with grey-box modelling are used to estimate the amount of deposits in the sewer system. The pollutant mass flow at the wastewater treatment plant is found to consist of a diurnal profile minus the deposited amount of pollutants...

  15. Related regulation of quality control of industrial products

    International Nuclear Information System (INIS)

    1983-04-01

    This book introduce related regulation of quality control of industrial products, which includes regulations of industrial products quality control, enforcement ordinance of industrial products quality control, enforcement regulation of quality control of industrial products, designated items with industrial production quality indication, industrial production quality test, and industrial production quality test organization and management tips of factory quality by grade.

  16. Pollution control activities for waste-water treatment plants: planning, integrated approach, functionality controls and small plants

    International Nuclear Information System (INIS)

    Serena, F.; Tomiato, L.; Ostoich, M.; Falletti, L.

    2009-01-01

    The work presents the problem of the Wastewater Treatment Plants' (WWTPs) controls and the organization of the consequential activities with reference to the priorities of the Environmental Agencies through a hierarchy assessment according to the environmental importance of the pressure sources. The European Recommendation 2001/331/EC bases the environmental controls of industrial sites and also of WWTPs on an integrated approach overtaking the simple analytic control; the integrated approach requires documentary, technical, management and analytic controls. The Veneto Regional Environmental Prevention and Protection Agency (ARPAV) has recently developed and applied a check-list for the implementation of the European Recommendation for WWTPs. The check-list includes the functionality assessment of the WWTP in case of discharge control delegation to the plant manager as consented with Annex 5 third part Italian Decree 3/04/2006 n. 152. In the paper the general framework of environmental controls on public WWTPs in the Veneto region is described. Particular importance for the numerousness and for the required control typology is referred to the small WWTP ( [it

  17. Quality control of nuclear medicine instrumentation

    International Nuclear Information System (INIS)

    Mould, R.F.

    1983-09-01

    The proceedings of a conference held by the Hospital Physicists' Association in London 1983 on the quality control of nuclear medicine instrumentation are presented. Section I deals with the performance of the Anger gamma camera including assessment during manufacture, acceptance testing, routine testing and long-term assessment of results. Section II covers interfaces, computers, the quality control problems of emission tomography and the quality of software. Section III deals with radionuclide measurement and impurity assessment and Section IV the presentation of images and the control of image quality. (U.K.)

  18. Developing methods of controlling quality costs

    OpenAIRE

    Gorbunova A. V.; Maximova O. N.; Ekova V. A.

    2017-01-01

    The article examines issues of managing quality costs, problems of applying economic methods of quality control, implementation of progressive methods of quality costs management in enterprises with the view of improving the efficiency of their evaluation and analysis. With the aim of increasing the effectiveness of the cost management mechanism, authors introduce controlling as a tool of deviation analysis from the standpoint of the process approach. A list of processes and corresponding eva...

  19. Effects of different irrigation practices using treated wastewater on tomato yields, quality, water productivity, and soil and fruit mineral contents.

    Science.gov (United States)

    Demir, Azize Dogan; Sahin, Ustun

    2017-11-01

    Wastewater use in agricultural irrigation is becoming a common practice in order to meet the rising water demands in arid and semi-arid regions. The study was conducted to determine the effects of the full (FI), deficit (DI), and partial root-zone drying (PRD) irrigation practices using treated municipal wastewater (TWW) and freshwater (FW) on tomato yield, water use, fruit quality, and soil and fruit heavy metal concentrations. The TWW significantly increased marketable yield compared to the FW, as well as decreased water consumption. Therefore, water use efficiency (WUE) in the TWW was significantly higher than in the FW. Although the DI and the PRD practices caused less yields, these practices significantly increased WUE values due to less irrigation water applied. The water-yield linear relationships were statistically significant. TWW significantly increased titratable acidity and vitamin C contents. Reduced irrigation provided significantly lower titratable acidity, vitamin C, and lycopene contents. TWW increased the surface soil and fruit mineral contents in response to FW. Greater increases were observed under FI, and mineral contents declined with reduction in irrigation water. Heavy metal accumulation in soils was within safe limits. However, Cd and Pb contents in fruits exceeded standard limits given by FAO/WHO. Higher metal pollution index values determined for fruits also indicated that TWW application, especially under FI, might cause health risks in long term.

  20. Summary of Organic Wastewater Compounds and Other Water-Quality Data in Charles County, Maryland, October 2007 through August 2008

    Science.gov (United States)

    Lorah, Michelle M.; Soeder, Daniel J.; Teunis, Jessica A.

    2010-01-01

    The U.S. Geological Survey, in cooperation with the government of Charles County, Maryland, and the Port Tobacco River Conservancy, Inc., conducted a water-quality reconnaissance and sampling investigation of the Port Tobacco River and Nanjemoy Creek watersheds in Charles County during October 2007 and June-August 2008. Samples were collected and analyzed for major ions, nutrients, organic wastewater compounds, and other selected constituents from 17 surface-water sites and 11 well sites (5 of which were screened in streambed sediments to obtain porewater samples). Most of the surface-water sites were relatively widely spaced throughout the Port Tobacco River and Nanjemoy Creek watersheds, although the well sites and some associated surface-water sites were concentrated in one residential community along the Port Tobacco River that has domestic septic systems. Sampling for enterococci bacteria was conducted by the Port Tobacco River Conservancy, Inc., at each site to coordinate with the sampling for chemical constituents. The purpose of the coordinated sampling was to determine correlations between historically high, in-stream bacteria counts and human wastewater inputs. Chemical data for the groundwater, porewater, and surface-water samples are presented in this report.

  1. Water Quality Monitoring Around Submerged Wastewater Outfalls in Southern California: From Compliance Assessment to Impact of Climate Change

    Science.gov (United States)

    Nezlin, N. P.

    2016-02-01

    Routine monitoring near major submerged ocean outfalls in southern California is focused on the assessment of the effects of wastewater discharge on water-quality (WQ), including dissolved oxygen, pH, transmissivity, and phytoplankton biomass. The proposed WQ compliance assessment using DO as an indicator includes 1) identification of the area affected by effluent wastewater using Colored Dissolved Organic Matter (CDOM) as an effluent plume tracer, 2) selection of reference sampling sites representing `natural' conditions, and 3) comparison between DO profiles in the reference and plume-affected zones. This strategy is implemented as an interactive web-based tool including convenient data visualization options. At the same time, the data of WQ monitoring (regular quarterly observations starting 1998-present) provides an excellent platform to analyze the spatial and temporal (seasonal and interannual) variations in near-shore ocean ecosystem. An illustrative example is the trends in the depths of the euphotic layer and subsurface chlorophyll maximum layer (SCML), abruptly deepening during the most recent four-year period (2011-2014). These dramatic changes are associated with declining intensity of the North Pacific gyre circulation (NPGO index), decreasing upwelling and increasing transport of warm water from equatorial Pacific (PDO and ENSO cycles).

  2. Substrates of Mauritia flexuosa and wastewater from pig farming on growth and quality in seedlings of Acacia mangium

    Directory of Open Access Journals (Sweden)

    Emanuel França Araújo

    Full Text Available ABSTRACT Sustainable alternatives should be adopted to minimise the negative environmental impacts of agricultural activities. The use of wastewater as well as organic waste, from agricultural activities or found naturally, such as the decomposed stems of the Buriti palm (Mauritia flexuosa, can be a sustainable alternative in the production of seedlings for the reforestation of areas in the process of degradation or desertification, common in the State of Piauí, Brazil. The aim of this study was to evaluate growth and quality in seedlings of Acacia mangium Willd grown in substrates with different proportions of decomposed stems of Mauritia flexuosa (DSB, and irrigated with wastewater from pig farming (WPF. The experimental design was completely randomised, arranged in a 5 x 2 factorial scheme, corresponding to five proportions of DSB and soil (v/v,% - 0:100, 20:80, 40:60, 60:40, 80:20, and two sources of irrigation water (well water and WPF, with four replications. At 100 days after sowing (DAS, the seedlings were collected to measure the variables related to growth, quality and nodulation. Height, root collar diameter, shoot dry weight, leaf area and nitrogen accumulation in the shoots were significantly influenced (p≤0.05 by the interaction between substrate and source of irrigation water. The WPF had no significant influence on the growth or quality of the Acacia mangium Willd seedlings. The best ratio between DSB substrate and soil was 46:54, considered the most suitable for seedling production in Acacia mangium Willd.

  3. Fuel manufacture and quality control

    International Nuclear Information System (INIS)

    Roepenack, H.; Raab, K.

    1975-01-01

    The different steps in fuel and fuel element manufacturing from the conversion of UF 6 to UO 2 to the assembling of the whole fuel element are shortly described. Each of this fabrication steps must satisfy well-defined quality criteria which are checked in certain analyses or tests. (RB) [de

  4. Effluent quality of a conventional activated sludge and a membrane bioreactor system treating hospital wastewater

    International Nuclear Information System (INIS)

    Pauwels, B.; Ngwa, F.; Deconinck, S.; Verstraete, W.

    2005-01-01

    Two lab scale wastewater treatment plants treating hospital wastewater in parallel were compared in terms of performance characteristics. One plant consisted of a conventional activated sludge system (CAS) and comprised In anoxic and aerobic compartment followed by a settling tank with recycle loop. The second pilot plant was a -late membrane bioreactor (MBR). The wastewater as obtained from the hospital had a variable COD (Chemical Oxygen Demand) ranging from 250 to 2300 mg/L. Both systems were operated at a similar hydraulic residence time of 12 hours. The reference conventional activated sludge system did not meet the regulatory standard for effluent COD of 125 mg /L most of the time. Its COD removal efficiency was 88%. The plate MBR delivered an effluent with a COD value of 50 mg/L or less, and attained an efficiency of 93%. The effluent contained no suspended particles. In addition, the MBR resulted in consistent operational parameters with a flux remaining around 8 -10 L/m/sup 2/.h and a trans membrane pressure <0.1 bar without the need for backwash or chemical cleaning. The CAS and the MBR system performed equally good in terms of TAN removal and EE2 removal. The CAS system typically decreased bacterial groups for about 1 log unit, whereas the MBR decreased these groups for about 3 log units. Enterococci were decreased below the detection limit in the MBR and indicator organisms such as fecal coliforms were decreased for 1.4 log units in the CAS system compared to a 3.6 log removal in the MBR. (author)

  5. Quality Control in Mammography: Image Quality and Patient Doses

    International Nuclear Information System (INIS)

    Ciraj Bjelac, O.; Arandjic, D.; Boris Loncar, B.; Kosutic, D.

    2008-01-01

    Mammography is method of choice for early detection of breast cancer. The purpose of this paper is preliminary evaluation the mammography practice in Serbia, in terms of both quality control indicators, i.e. image quality and patient doses. The survey demonstrated considerable variations in technical parameters that affect image quality and patients doses. Mean glandular doses ranged from 0.12 to 2.8 mGy, while reference optical density ranged from 1.2 to 2.8. Correlation between image contrast and mean glandular doses was demonstrated. Systematic implementation of quality control protocol should provide satisfactory performance of mammography units and maintain satisfactory image quality and keep patient doses as low as reasonably practicable. (author)

  6. Wastewater Outfalls

    Data.gov (United States)

    Iowa State University GIS Support and Research Facility — Outfalls which discharge wastewater from wastewater treatment facilities with individual NPDES permits. It does not include NPDES general permits.

  7. The removal of pharmaceuticals, personal care products, endocrine disruptors and illicit drugs during wastewater treatment and its impact on the quality of receiving waters.

    Science.gov (United States)

    Kasprzyk-Hordern, Barbara; Dinsdale, Richard M; Guwy, Alan J

    2009-02-01

    A 5-month monitoring program was undertaken in South Wales in the UK to determine the fate of 55 pharmaceuticals, personal care products, endocrine disruptors and illicit drugs (PPCPs) in two contrasting wastewater plants utilising two different wastewater treatment technologies: activated sludge and trickling filter beds. The impact of treated wastewater effluent on the quality of receiving waters was also assessed. PPCPs were found to be present at high loads reaching 10kgday(-1) in the raw sewage. Concentrations of PPCPs in raw sewage were found to correlate with their usage/consumption patterns in Wales and their metabolism. The efficiency of the removal of PPCPs was found to be strongly dependent on the technology implemented in the wastewater treatment plant (WWTP). In general, the WWTP utilising trickling filter beds resulted in, on average, less than 70% removal of all 55 PPCPs studied, while the WWTP utilising activated sludge treatment gave a much higher removal efficiency of over 85%. The monitoring programme revealed that treated wastewater effluents were the main contributors to PPCPs concentrations (up to 3kg of PPCPsday(-1)) in the rivers studied. Bearing in mind that in the cases examined here the WWTP effluents were also major contributors to rivers' flows (dilution factor for the studied rivers did not exceed 23 times) the effect of WWTP effluent on the quality of river water is significant and cannot be underestimated.

  8. Quality control in the radioactive waste management

    International Nuclear Information System (INIS)

    Rzyski, B.M.

    1989-01-01

    Radioactive waste management as in industrial activities must mantain in all steps a quality control programme. This control extended from materials acquisition, for waste treatment, to the package deposition is one of the most important activities because it aims to observe the waste acceptance criteria in repositories and allows to guarantee the security of the nuclear facilities. In this work basic knowledges about quality control in waste management and some examples of adopted procedures in other countries are given. (author) [pt

  9. Modeling of wastewater quality in an urban area during festival and rainy days.

    Science.gov (United States)

    Obaid, H A; Shahid, S; Basim, K N; Chelliapan, S

    2015-01-01

    Water pollution during festival periods is a major problem in all festival cities across the world. Reliable prediction of water pollution is essential in festival cities for sewer and wastewater management in order to ensure public health and a clean environment. This article aims to model the biological oxygen demand (BOD(5)), and total suspended solids (TSS) parameters in wastewater in the sewer networks of Karbala city center during festival and rainy days using structural equation modeling and multiple linear regression analysis methods. For this purpose, 34 years (1980-2014) of rainfall, temperature and sewer flow data during festival periods in the study area were collected, processed, and employed. The results show that the TSS concentration increases by 26-46 mg/l while BOD(5) concentration rises by 9-19 mg/l for an increase of rainfall by 1 mm during festival periods. It was also found that BOD(5) concentration rises by 4-17 mg/l for each increase of 10,000 population.

  10. Biochar can be used to recapture essential nutrients from dairy wastewater and improve soil quality

    Science.gov (United States)

    Ghezzehei, T. A.; Sarkhot, D. V.; Berhe, A. A.

    2014-04-01

    Recently, the potential for biochar use to recapture excess nutrients from dairy wastewater has been a focus of a growing number of studies. It is suggested that biochar produced from locally available waste biomass can be important in reducing release of excess nutrient elements from agricultural runoff, improving soil productivity, and long-term carbon (C) sequestration. Here we present a review of a new approach that is showing promise for the use of biochar for nutrient capture. Using batch sorption experiments, it has been shown that biochar can adsorb up to 20 to 43% of ammonium and 19-65% of the phosphate in flushed dairy manure in 24 h. These results suggest a potential of biochar for recovering essential nutrients from dairy wastewater and improving soil fertility if the enriched biochar is returned to soil. Based on the sorption capacity of 2.86 and 0.23 mg ammonium and phosphate, respectively, per gram of biochar and 10-50% utilization of available excess biomass, in the state of California (US) alone, 11 440 to 57 200 t of ammonium-N and 920-4600 t of phosphate can be captured from dairy waste each year while at the same time disposing up to 8-40 million tons of waste biomass.

  11. Metagenomic approaches for direct and cell culture evaluation of the virological quality of wastewater

    Energy Technology Data Exchange (ETDEWEB)

    Aw, Tiong Gim; Howe, Adina; Rose, Joan B.

    2014-12-01

    Genomic-based molecular techniques are emerging as powerful tools that allow a comprehensive characterization of water and wastewater microbiomes. Most recently, next generation sequencing (NGS) technologies which produce large amounts of sequence data are beginning to impact the field of environmental virology. In this study, NGS and bioinformatics have been employed for the direct detection and characterization of viruses in wastewater and of viruses isolated after cell culture. Viral particles were concentrated and purified from sewage samples by polyethylene glycol precipitation. Viral nucleic acid was extracted and randomly amplified prior to sequencing using Illumina technology, yielding a total of 18 million sequence reads. Most of the viral sequences detected could not be characterized, indicating the great viral diversity that is yet to be discovered. This sewage virome was dominated by bacteriophages and contained sequences related to known human pathogenic viruses such as adenoviruses (species B, C and F), polyomaviruses JC and BK and enteroviruses (type B). An array of other animal viruses was also found, suggesting unknown zoonotic viruses. This study demonstrated the feasibility of metagenomic approaches to characterize viruses in complex environmental water samples.

  12. Control by quality: proposition of a typology.

    Science.gov (United States)

    Pujo, P; Pillet, M

    The application of Quality tools and methods in industrial management has always had a fundamental impact on the control of production. It influences the behavior of the actors concerned, while introducing the necessary notions and formalizations, especially for production systems with little or no automation, which constitute a large part of the industrial activity. Several quality approaches are applied in the workshop and are implemented at the level of the control. In this paper, the authors present a typology of the various approaches that have successively influenced control, such as statistical process control, quality assurance, and continuous improvement. First the authors present a parallel between production control and quality organizational structure. They note the duality between control, which is aimed at increasing productivity, and quality, which aims to satisfy the needs of the customer. They also note the hierarchical organizational structure of these two systems of management with, at each level, the notion of a feedback loop. This notion is fundamental to any kind of decision making. The paper is organized around the operational, tactical, and strategic levels, by describing for each level the main methods and tools for control by quality. The overview of these tools and methods starts at the operational level, with the Statistical Process Control, the Taguchi technique, and the "six sigma" approach. On the tactical level, we find a quality system approach, with a documented description of the procedures introduced in the firm. The management system can refer here to Quality Assurance, Total Productive Maintenance, or Management by Total Quality. The formalization through procedures of the rules of decision governing the process control enhances the validity of these rules. This leads to the enhancement of their reliability and to their consolidation. All this counterbalances the human, intrinsically fluctuating, behavior of the control

  13. Sensometrics for Food Quality Control

    DEFF Research Database (Denmark)

    Brockhoff, Per B.

    2011-01-01

    The industrial development of innovative and succesful food items and the measuring of food quality in general is difficult without actually letting human beings evaluate the products using their senses at some point in the process. The use of humans as measurement instruments calls for special...... attention in the modelling and data analysis phase. In this paper the focus is on sensometrics – the „metric“ side of the sensory science field. The sensometrics field is introduced and related to the fields of statistics, chemometrics and psychometrics. Some of the most commonly used sensory testing...

  14. Computer controlled quality of analytical measurements

    International Nuclear Information System (INIS)

    Clark, J.P.; Huff, G.A.

    1979-01-01

    A PDP 11/35 computer system is used in evaluating analytical chemistry measurements quality control data at the Barnwell Nuclear Fuel Plant. This computerized measurement quality control system has several features which are not available in manual systems, such as real-time measurement control, computer calculated bias corrections and standard deviation estimates, surveillance applications, evaluaton of measurement system variables, records storage, immediate analyst recertificaton, and the elimination of routine analysis of known bench standards. The effectiveness of the Barnwell computer system has been demonstrated in gathering and assimilating the measurements of over 1100 quality control samples obtained during a recent plant demonstration run. These data were used to determine equaitons for predicting measurement reliability estimates (bias and precision); to evaluate the measurement system; and to provide direction for modification of chemistry methods. The analytical chemistry measurement quality control activities represented 10% of the total analytical chemistry effort

  15. TRAINING SYSTEM OF FUTURE SPECIALISTS: QUALITY CONTROL

    Directory of Open Access Journals (Sweden)

    Vladimir A. Romanov

    2015-01-01

    Full Text Available The aim of the investigation is development of innovative strategy of quality control training of engineers and skilled workers (hereinafter – future specialists in educational professional organizations on the principles of social partnership.Methods. Theoretic: theoretic and methodological analysis, polytheoretic synthesis, modeling. Empirical: research and generalization of the system, process and competence – based approaches experience, experiment, observation, surveys, expert evaluation, SWOT-analysis as a method of strategic planning which is to identify the internal and external factors (socio-cultural of the organization surrounding.Results. The strategy of the development of the process of quality control training in educational professional organizations and a predictive model of the system of quality control training for future engineers and workers have been created on the analysis and synthesis of a quantitative specification of the quality, the obtained experience and success in control training of future specialists in educational professional organizations in recent economic and educational conditions.Scientific novelty. There has been built a predicative model of quality control training of future specialists to meet modern standards and the principles of social partnership; the control algorithm of the learning process, developed in accordance with the standards (international of quality ISO in the implementation of the quality control systems of the process approach (matrix-based responsibility, competence and remit of those responsible for the education process in the educational organization, the «problem» terms and diagnostic tools for assessing the quality of professional training of future specialists. The perspective directions of innovation in the control of the quality of future professionals training have been determined; the parameters of a comprehensive analysis of the state of the system to ensure the

  16. CONCRETE STRUCTURES' QUALITY CONTROL IN PRACTICE

    OpenAIRE

    Dolaček-Alduk, Zlata; Blanda, Miroslav

    2011-01-01

    The Croatian civil engineering is characterized by a lack of systematic approach to planning, control and quality assurance in all phases of project realization. The results obtained in establishing the quality management system in some segments of civil engineering production represent initial trends in solving this problem. Benefits are of two types: the achievement of quality for the contractor and obtaining that quaity is being achieved for clients. Execution of concrete structures is a c...

  17. A quality control manual for oral radiology

    International Nuclear Information System (INIS)

    Peixoto, J.E.; Ferreira, R.S.; Bessa, S.O.; Domingues, C.; Gomes, C.A.; Oliveira, S.L.G.; Ortiz, J.A.P.

    1988-01-01

    A quality control manual for oral radiology is showed. The X-ray equipment used for this activity is described, such as the X-ray tube, collimator. The high tension in X-ray tube, the spectra, the quality and the quantity of radiation and the X-ray intensity are also analysed. (C.G.C.) [pt

  18. Quality control of gamma radiation measuring systems

    International Nuclear Information System (INIS)

    Surma, M.J.

    2002-01-01

    The problem of quality control and assurance of gamma radiation measuring systems has been described in detail. The factors deciding of high quality of radiometric measurements as well as statistical testing and calibration of measuring systems have been presented and discussed

  19. Net analyte signal based statistical quality control

    NARCIS (Netherlands)

    Skibsted, E.T.S.; Boelens, H.F.M.; Westerhuis, J.A.; Smilde, A.K.; Broad, N.W.; Rees, D.R.; Witte, D.T.

    2005-01-01

    Net analyte signal statistical quality control (NAS-SQC) is a new methodology to perform multivariate product quality monitoring based on the net analyte signal approach. The main advantage of NAS-SQC is that the systematic variation in the product due to the analyte (or property) of interest is

  20. The regulatory maze of quality control

    International Nuclear Information System (INIS)

    Stone, T.I.

    1987-01-01

    The appropriateness of specific procedures within a quality control program becomes difficult to assess when an attempt is made to collate all of the available information. This task is discussed from the perspective of the Joint Commission (JCAH Accreditation Manual), HHS(quality assurance program recommendations), equipment manufacturers maintenance schedules, and radiology administrative cost concerns

  1. Benchmarking Water Quality from Wastewater to Drinking Waters Using Reduced Transcriptome of Human Cells.

    Science.gov (United States)

    Xia, Pu; Zhang, Xiaowei; Zhang, Hanxin; Wang, Pingping; Tian, Mingming; Yu, Hongxia

    2017-08-15

    One of the major challenges in environmental science is monitoring and assessing the risk of complex environmental mixtures. In vitro bioassays with limited key toxicological end points have been shown to be suitable to evaluate mixtures of organic pollutants in wastewater and recycled water. Omics approaches such as transcriptomics can monitor biological effects at the genome scale. However, few studies have applied omics approach in the assessment of mixtures of organic micropollutants. Here, an omics approach was developed for profiling bioactivity of 10 water samples ranging from wastewater to drinking water in human cells by a reduced human transcriptome (RHT) approach and dose-response modeling. Transcriptional expression of 1200 selected genes were measured by an Ampliseq technology in two cell lines, HepG2 and MCF7, that were exposed to eight serial dilutions of each sample. Concentration-effect models were used to identify differentially expressed genes (DEGs) and to calculate effect concentrations (ECs) of DEGs, which could be ranked to investigate low dose response. Furthermore, molecular pathways disrupted by different samples were evaluated by Gene Ontology (GO) enrichment analysis. The ability of RHT for representing bioactivity utilizing both HepG2 and MCF7 was shown to be comparable to the results of previous in vitro bioassays. Finally, the relative potencies of the mixtures indicated by RHT analysis were consistent with the chemical profiles of the samples. RHT analysis with human cells provides an efficient and cost-effective approach to benchmarking mixture of micropollutants and may offer novel insight into the assessment of mixture toxicity in water.

  2. Quality Control Guidelines for SAM Biotoxin Methods

    Science.gov (United States)

    Learn more about quality control guidelines and recommendations for the analysis of samples using the pathogen methods listed in EPA's Selected Analytical Methods for Environmental Remediation and Recovery (SAM).

  3. Quality Control Guidelines for SAM Radiochemical Methods

    Science.gov (United States)

    Learn more about quality control guidelines and recommendations for the analysis of samples using the radiochemistry methods listed in EPA's Selected Analytical Methods for Environmental Remediation and Recovery (SAM).

  4. Quality Control Guidelines for SAM Pathogen Methods

    Science.gov (United States)

    Learn more about quality control guidelines and recommendations for the analysis of samples using the biotoxin methods listed in EPA's Selected Analytical Methods for Environmental Remediation and Recovery (SAM).

  5. Quality Control Guidelines for SAM Chemical Methods

    Science.gov (United States)

    Learn more about quality control guidelines and recommendations for the analysis of samples using the chemistry methods listed in EPA's Selected Analytical Methods for Environmental Remediation and Recovery (SAM).

  6. Metallographic quality control of welding and brazing

    International Nuclear Information System (INIS)

    Slaughter, G.M.

    1979-01-01

    The value of metallography in assuring integrity in the fabrication of metal and components in energy systems is summarized. Metallography also plays an integral role in quality control of welded and brazed joints

  7. Quality Controlled Local Climatological Data (QCLCD) Publication

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Quality Controlled Local Climatological Data (QCLCD) contains summaries from major airport weather stations that include a daily account of temperature extremes,...

  8. Quality control during construction of power plants

    International Nuclear Information System (INIS)

    Hartstern, R.F.

    1982-01-01

    This paper traces the background and examines the necessity for a program to control quality during the construction phase of a power plant. It also attempts to point out considerations for making these programs cost effective

  9. Multi-criteria evaluation of wastewater treatment plant control strategies under uncertainty.

    Science.gov (United States)

    Flores-Alsina, Xavier; Rodríguez-Roda, Ignasi; Sin, Gürkan; Gernaey, Krist V

    2008-11-01

    The evaluation of activated sludge control strategies in wastewater treatment plants (WWTP) via mathematical modelling is a complex activity because several objectives; e.g. economic, environmental, technical and legal; must be taken into account at the same time, i.e. the evaluation of the alternatives is a multi-criteria problem. Activated sludge models are not well characterized and some of the parameters can present uncertainty, e.g. the influent fractions arriving to the facility and the effect of either temperature or toxic compounds on the kinetic parameters, having a strong influence in the model predictions used during the evaluation of the alternatives and affecting the resulting rank of preferences. Using a simplified version of the IWA Benchmark Simulation Model No. 2 as a case study, this article shows the variations in the decision making when the uncertainty in activated sludge model (ASM) parameters is either included or not during the evaluation of WWTP control strategies. This paper comprises two main sections. Firstly, there is the evaluation of six WWTP control strategies using multi-criteria decision analysis setting the ASM parameters at their default value. In the following section, the uncertainty is introduced, i.e. input uncertainty, which is characterized by probability distribution functions based on the available process knowledge. Next, Monte Carlo simulations are run to propagate input through the model and affect the different outcomes. Thus (i) the variation in the overall degree of satisfaction of the control objectives for the generated WWTP control strategies is quantified, (ii) the contributions of environmental, legal, technical and economic objectives to the existing variance are identified and finally (iii) the influence of the relative importance of the control objectives during the selection of alternatives is analyzed. The results show that the control strategies with an external carbon source reduce the output uncertainty

  10. Assessing Receiving Water Quality Impacts due to Flow Path Alteration in Residential Catchments, using the Stormwater and Wastewater Management Model

    Science.gov (United States)

    Wolosoff, S. E.; Duncan, J.; Endreny, T.

    2001-05-01

    The Croton water supply system, responsible for supplying approximately 10% of New York City's water, provides an opportunity for exploration into the impacts of significant terrestrial flow path alteration upon receiving water quality. Natural flow paths are altered during residential development in order to allow for construction at a given location, reductions in water table elevation in low lying areas and to provide drainage of increased overland flow volumes. Runoff conducted through an artificial drainage system, is prevented from being attenuated by the natural environment, thus the pollutant removal capacity inherent in most natural catchments is often limited to areas where flow paths are not altered by development. By contrasting the impacts of flow path alterations in two small catchments in the Croton system, with different densities of residential development, we can begin to identify appropriate limits to the re-routing of runoff in catchments draining into surface water supplies. The Stormwater and Wastewater Management Model (SWMM) will be used as a tool to predict the runoff quantity and quality generated from two small residential catchments and to simulate the potential benefits of changes to the existing drainage system design, which may improve water quality due to longer residence times.

  11. Water quality modelling and optimisation of wastewater treatment network using mixed integer programming

    CSIR Research Space (South Africa)

    Mahlathi, Christopher

    2016-10-01

    Full Text Available Instream water quality management encompasses field monitoring and utilisation of mathematical models. These models can be coupled with optimisation techniques to determine more efficient water quality management alternatives. Among these activities...

  12. Developing methods of controlling quality costs

    Directory of Open Access Journals (Sweden)

    Gorbunova A. V.

    2017-01-01

    Full Text Available The article examines issues of managing quality costs, problems of applying economic methods of quality control, implementation of progressive methods of quality costs management in enterprises with the view of improving the efficiency of their evaluation and analysis. With the aim of increasing the effectiveness of the cost management mechanism, authors introduce controlling as a tool of deviation analysis from the standpoint of the process approach. A list of processes and corresponding evaluation criteria in the quality management system of enterprises is introduced. Authors also introduce the method of controlling quality costs and propose it for the practical application, which allows them to determine useful and unnecessary costs at the existing operating plant. Implementing the proposed recommendations in the system of cost management at an enterprise will allow to improve productivity of processes operating and reduce wasted expense on the quality of the process on the basis of determining values of useful and useless costs of quality according to criteria of processes functioning in the system of quality management.

  13. Improvement of Hydraulic and Water Quality Renovation Functions by Intermittent Aeration of Soil Treatment Areas in Onsite Wastewater Treatment Systems

    Directory of Open Access Journals (Sweden)

    David V. Kalen

    2010-12-01

    Full Text Available We tested intermittent aeration of the soil treatment area (STA of onsite wastewater treatment systems (OWTS for its ability to restore and maintain STA hydraulic flow and improve the water quality functions of conventional OWTS. Evaluation was conducted on hydraulically-failed conventional OWTS at three state-owned medical group homes in Washington County, RI, USA. Testing was conducted in two phases, with Phase I (before intermittent soil aeration (ISA comprising the first 6 months of the study, and Phase II (during ISA the remaining 7 months. Intermittent soil aeration restored STA hydraulic function in all three systems despite a marked reduction in the STA total infiltrative surface. Soil pore water was collected from 30 and 90 cm below the STA during both phases and analyzed for standard wastewater parameters. Although the STA infiltrative surface was reduced—and the contaminant load per unit of area increased—after installation of the ISA system, no differences were observed between phases in concentration of total N, NO3, total P, or dissolved organic carbon (DOC. Apparent removal rates—which do not account for dilution or differences in infiltrative area—for total N, total P, and DOC remained the same or improved during Phase II relative to the pre-operation phase. Furthermore, intermittent soil aeration enhanced actual removal rates —which do account for dilution and differences in infiltrative area. The effects of ISA on actual removal of contaminants from STE increased with increasing hydraulic load—a counterintuitive phenomenon, but one that has been previously observed in laboratory studies. The results of our study suggest that intermittent soil aeration can restore and maintain hydraulic flow in the STA and enhance carbon and nutrient removal in conventional OWTS.

  14. Quality assurance and quality control in mammography: A review

    International Nuclear Information System (INIS)

    BenComo, Jose A.

    2000-01-01

    A mammogram is among the most technically demanding radiographic procedures. The early detection of breast cancer relies on the radiologist's ability to perceive subtle changes in the image that are only perceptible with high-quality imaging. Early detection of breast cancer is only as reliable as the mammogram with which a diagnosis is made, and a mammogram is only as accurate as the system that produces it. A quality assurance (QA) program maximizes the likelihood that the mammographic images will provide adequate diagnostic information for the least possible radiation exposure and cost to the patient. The QA program monitors each phase of operation of the imaging facility beginning with the request for an examination and ending with the interpretation of the referring physician and ensures that the imaging equipment used for the examination will yield the information desired. Because image quality is the most important technical aspect of mammography, this review summarizes the most important QA and quality control issues

  15. Quality control and analysis of radiotracer compounds

    International Nuclear Information System (INIS)

    Sheppard, G.; Thomson, R.

    1977-01-01

    Special emphasis was on the problems and errors possible in quality control and analysis. The principles underlying quality control were outlined, and analytical techniques applicable to radiotracers were described. Chapter concluded with a selection of examples showing the effects of impurities on the use of radiotracers. The subject of quality control and analysis was treated from the viewpoint of the user and those research workers who need to synthesize and analyze their own radiochemicals. The quality characteristics for radiotracers are of two kinds, valuable or attributive. These were discussed in the chapter. For counting low radioactive concentration, scintillation techniques are in general use, whereas ionization techniques are now used mainly for the measurement of high radioactive concentrations or large quantities of radioactivity, for scanning chromatograms, and a number of very specific purposes. Determination of radionuclidic purity was discussed. Use of radiotracers in pharmaceuticals were presented. 4 figures, 6 tables

  16. Network-based production quality control

    Science.gov (United States)

    Kwon, Yongjin; Tseng, Bill; Chiou, Richard

    2007-09-01

    This study investigates the feasibility of remote quality control using a host of advanced automation equipment with Internet accessibility. Recent emphasis on product quality and reduction of waste stems from the dynamic, globalized and customer-driven market, which brings opportunities and threats to companies, depending on the response speed and production strategies. The current trends in industry also include a wide spread of distributed manufacturing systems, where design, production, and management facilities are geographically dispersed. This situation mandates not only the accessibility to remotely located production equipment for monitoring and control, but efficient means of responding to changing environment to counter process variations and diverse customer demands. To compete under such an environment, companies are striving to achieve 100%, sensor-based, automated inspection for zero-defect manufacturing. In this study, the Internet-based quality control scheme is referred to as "E-Quality for Manufacturing" or "EQM" for short. By its definition, EQM refers to a holistic approach to design and to embed efficient quality control functions in the context of network integrated manufacturing systems. Such system let designers located far away from the production facility to monitor, control and adjust the quality inspection processes as production design evolves.

  17. Real-time control of oxic phase using pH (mV)-time profile in swine wastewater treatment

    International Nuclear Information System (INIS)

    Ga, C.H.; Ra, C.S.

    2009-01-01

    The feasibility of real-time control of the oxic phase using the pH (mV)-time profile in a sequencing batch reactor for swine wastewater treatment was evaluated, and the characteristics of the novel real-time control strategies were analyzed in two different concentrated wastewaters. The nitrogen break point (NBP) on the moving slope change (MSC) of the pH (mV) was designated as a real-time control point, and a pilot-scale sequencing batch reactor (18 m 3 ) was designed to fulfill the objectives of the study. Successful real-time control using the developed control strategy was achieved despite the large variations in the influent strength and the loading rate per cycle. Indeed, complete and consistent removal of NH 4 -N (100% removal) was achieved. There was a strong positive correlation (r 2 = 0.9789) between the loading rate and soluble total organic carbon (TOCs) removal, and a loading rate of 100 g/m 3 /cycle was found to be optimum for TOCs removal. Experimental data showed that the real-time control strategy using the MSC of the pH (mV)-time profile could be utilized successfully for the removal of nitrogen from swine wastewater. Furthermore, the pH (mV) was a more reliable real-time control parameter than the oxidation-reduction potential (ORP) for the control of the oxic phase. However, the nitrate knee point (NKP) appeared more consistently upon the completion of denitrification on the ORP-time profile than on the pH (mV)-time profile.

  18. 20. Quality assurance and quality control in nuclear medicine

    International Nuclear Information System (INIS)

    Vavrejn, B.

    1989-01-01

    Quality control principles to be applied when taking over and using nuclear medicine instrumentation are given. Such instrumentation includes activity meters, gamma detectors for in vitro measurements (manual or automated instruments), gamma detectors for in vivo measurements (with one or several probes), 'movable' scintigraphs and 'steady' scintigraphs (gamma cameras). (Z.S.)

  19. Development and assessment of an integrated ecological modelling framework to assess the effect of investments in wastewater treatment on water quality.

    Science.gov (United States)

    Holguin-Gonzalez, Javier E; Boets, Pieter; Everaert, Gert; Pauwels, Ine S; Lock, Koen; Gobeyn, Sacha; Benedetti, Lorenzo; Amerlinck, Youri; Nopens, Ingmar; Goethals, Peter L M

    2014-01-01

    Worldwide, large investments in wastewater treatment are made to improve water quality. However, the impacts of these investments on river water quality are often not quantified. To assess water quality, the European Water Framework Directive (WFD) requires an integrated approach. The aim of this study was to develop an integrated ecological modelling framework for the River Drava (Croatia) that includes physical-chemical and hydromorphological characteristics as well as the ecological river water quality status. The developed submodels and the integrated model showed accurate predictions when comparing the modelled results to the observations. Dissolved oxygen and nitrogen concentrations (ammonium and organic nitrogen) were the most important variables in determining the ecological water quality (EWQ). The result of three potential investment scenarios of the wastewater treatment infrastructure in the city of Varaždin on the EWQ of the River Drava was assessed. From this scenario-based analysis, it was concluded that upgrading the existing wastewater treatment plant with nitrogen and phosphorus removal will be insufficient to reach a good EWQ. Therefore, other point and diffuse pollution sources in the area should also be monitored and remediated to meet the European WFD standards.

  20. Quality control in 99m technetium radiopharmaceuticals

    International Nuclear Information System (INIS)

    Leon Cabana, Alba

    1994-01-01

    This work means about the quality control in Tc radiopharmaceuticals preparation at hospitalary levels. Several steps must be used in a Nuclear Medicine Laboratory, such as proceeding,radiopharmaceuticals kits preparation, and dispensation materials,glasses,stopper,physical aspects,identification,ph control,storage,and reactif kits

  1. Impact of the reusing of food manufacturing wastewater for irrigation in a closed system on the microbiological quality of the food crops.

    Science.gov (United States)

    Beneduce, Luciano; Gatta, Giuseppe; Bevilacqua, Antonio; Libutti, Angela; Tarantino, Emanuele; Bellucci, Micol; Troiano, Eleonora; Spano, Giuseppe

    2017-11-02

    In order to evaluate if the reuse of food industry treated wastewater is compatible for irrigation of food crops, without increased health risk, in the present study a cropping system, in which ground water and treated wastewater were used for irrigation of tomato and broccoli, during consecutive crop seasons was monitored. Water, crop environment and final products were monitored for microbial indicators and pathogenic bacteria, by conventional and molecular methods. The microbial quality of the irrigation waters influenced sporadically the presence of microbial indicators in soil. No water sample was found positive for pathogenic bacteria, independently from the source. Salmonella spp. and Listeria monocytogenes were detected in soil samples, independently from the irrigation water source. No pathogen was found to contaminate tomato plants, while Listeria monocytogenes and E. coli O157:H7 were detected on broccoli plant, but when final produce were harvested, no pathogen was detected on edible part. The level of microbial indicators and detection of pathogenic bacteria in field and plant was not dependent upon wastewater used. Our results, suggest that reuse of food industry wastewater for irrigation of agricultural crop can be applied without significant increase of potential health risk related to microbial quality. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. PACS quality control and automatic problem notifier

    Science.gov (United States)

    Honeyman-Buck, Janice C.; Jones, Douglas; Frost, Meryll M.; Staab, Edward V.

    1997-05-01

    One side effect of installing a clinical PACS Is that users become dependent upon the technology and in some cases it can be very difficult to revert back to a film based system if components fail. The nature of system failures range from slow deterioration of function as seen in the loss of monitor luminance through sudden catastrophic loss of the entire PACS networks. This paper describes the quality control procedures in place at the University of Florida and the automatic notification system that alerts PACS personnel when a failure has happened or is anticipated. The goal is to recover from a failure with a minimum of downtime and no data loss. Routine quality control is practiced on all aspects of PACS, from acquisition, through network routing, through display, and including archiving. Whenever possible, the system components perform self and between platform checks for active processes, file system status, errors in log files, and system uptime. When an error is detected or a exception occurs, an automatic page is sent to a pager with a diagnostic code. Documentation on each code, trouble shooting procedures, and repairs are kept on an intranet server accessible only to people involved in maintaining the PACS. In addition to the automatic paging system for error conditions, acquisition is assured by an automatic fax report sent on a daily basis to all technologists acquiring PACS images to be used as a cross check that all studies are archived prior to being removed from the acquisition systems. Daily quality control is preformed to assure that studies can be moved from each acquisition and contrast adjustment. The results of selected quality control reports will be presented. The intranet documentation server will be described with the automatic pager system. Monitor quality control reports will be described and the cost of quality control will be quantified. As PACS is accepted as a clinical tool, the same standards of quality control must be established

  3. Exposure parameters in fluoroscopy equipment. Quality control

    International Nuclear Information System (INIS)

    Alonso, M.; Castaneda, M.J.; Matorras, P.; Diaz-Caneja, N.; Gutierrez, I.

    1992-01-01

    Within the quality control program in Diagnostic Radiology currently being undertaken at the 'Marques de Valdecilla' University Hospital, the corresponding specification and procedure prototypes for the control of conventional radioscopy equipment have been elaborated and applied. This paper presents the values proposed in the specifications and those obtained for the following radioscopy equipment parameters: reference kerma, and its reproducibility, kerma linearity, maximum kerma at the skin, and total filtration. The results obtained indicate that the equipment studied could comply with specified requirements if a Maintenance Program were to be implemented in coordination with the Quality Control Program. (author)

  4. Effect of hog production wastewater in the development and quality of Eucalyptus urophylla substrate produced in urban solid waste

    Directory of Open Access Journals (Sweden)

    Raquel Oliveira Batista

    2013-08-01

    Full Text Available The objective of this study was to analyze the use of hog production wastewater in the production of seedlings of Eucalyptus urophylla, using a compound of municipal solid waste (SRSU as substrate, and evaluating the effect of different proportions of ARS and of seedling ages in their morphological and nutritional quality. The experiment was conducted in a greenhouse at the Experimental Hydraulics, Irrigation and Drainage, Department of Agricultural Engineering. The statistical design was randomized blocks with different numbers of repetitions, consisting of 10 treatments in a 5 x 2 factorial design (5 proportions of ARS supplemented with nitrogen fertilization and 2 seedling ages. The variables measured were shoot height (H, stem diameter (SD, shoot dry matter (SDM, root dry mass (RDM, total dry matter (TDM, ratio of seedling height / diameter of the girth (H / SD, ratio of dry weight of shoot / root dry mass (SDM / RDM, Dickson quality index (DQI and concentrations of nutrients in the plants leaf, stem and root. These characteristics were evaluated at 75 and 90 days after seeding (DAS. It was concluded that the proportion of 50% ARS improved the nutritional and morphological characteristics of eucalyptus. The seedlings achieved morphological characteristics suitable for planting in the field 90 days after sowing and showed appropriate levels for most nutrients at both ages.

  5. Quality Control and Quality Assurance of Radiation Oncology

    International Nuclear Information System (INIS)

    Abaza, A.

    2016-01-01

    Radiotherapy (RT) has played important roles in cancer treatment for more than one century. The development of RT techniques allows high-dose irradiation to tumors while reducing the radiation doses delivered to surrounding normal tissues. However, RT is a complex process and involves understanding of the principles of medical physics, radiobiology, radiation safety, dosimetry, radiation treatment planning, simulation and interaction of radiation with other treatment modalities. Each step in the integrated process of RT needs quality control and quality assurance (QA) to prevent errors and to ensure that patients will receive the prescribed treatment correctly. The aim of this study is to help the radio therapists in identifying a system for QA that balances patient safety and quality with available resources. Recent advances in RT focus on the need for a systematic RT QA program that balances patient safety and quality with available resources. It is necessary to develop more formal error mitigation and process analysis methods, such as failure mode and effect analysis (FMEA), to focus available QA resources optimally on the process components. External audit programs are also effective. Additionally, Clinical trial QA has a significant role in enhancing the quality of care. The International Atomic Energy Agency (IAEA) has operated both an on-site and off-site postal dosimetry audit to improve practice and to assure the dose from RT equipment. Both postal dosimetry audit and clinical trial RTQA, especially for advanced technologies, in collaboration with global networks, will serve to enhance patient safety and quality of care

  6. Following a drop of water from the cloud, throughout the sewer system, into the receiving water - Model predictive control of integrated sewer-wastewater treatment systems

    DEFF Research Database (Denmark)

    Mikkelsen, Peter Steen; Vezzaro, Luca; Sharma, Anitha Kumari

    This article presents selected examples of model-based prediction and control of integrated sewer-wastewater treatment systems, developed within the framework of the Storm- and Wastewater Informatics project (SWI). By exploiting all the available on-line information (e.g. radar based rainfall...... of pollutants discharged from treatment plants, etc.). The tools developed in the SWI project include (but are not limited to (i) rainfall nowcasting based on radar measurements, (ii) probabilistic flow forecasting based on data assimilation and stochastic models, (iii) prediction and optimization of wet......-weather performance of wastewater treatment plants, and (iv) integrated control of the different elements of the integrated wastewater systems. Full-scale testing of these tools in different catchment located in Denmark ensure that the developed tools can represent an important step forwards for on-line operation...

  7. Development of the gaharu oil quality control

    International Nuclear Information System (INIS)

    Chong Saw Peng; Mohd Fajri Osman; Shyful Azizi Abdul Rahman; Khairuddin Abdul Rahim; Mat Rasol Awang

    2010-01-01

    Gaharu (Agar wood) is a secondary metabolite produces by the Aquilaria spp. and accumulates in the plant cell in oleoresin form. The essential oil known as gaharu oil can be extracted from this oleoresin gaharu via varies extraction method such as the water distillation, solvent extraction, pressurize extraction and etc. The gaharu oil extracted through different methods will give different fragrances. Besides, different source of materials will also give different in chemical profiles. In gaharu oil trading market, most of the buyers request quality assurance from the gaharu oil manufacturer to assure the gaharu oil purchased meets their standard requirement. Since there is a demand on gaharu oil quality assurance then it become a need to develop the gaharu oil quality control method in order to have a standard quality control of gaharu oil presented in a certificate of analysis and verified by laboratory. (author)

  8. Quality control in diagnostic radiology - patient dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Prlic, I; Radalj, Z; Brumen, V; Cerovac, H [Institute for Medical Research and Occupational Health, Laboratory for Radiation Protection and Dosimetry, Zagreb (Croatia); Gladic, J [Institute for Physics, Laboratory for Solid State Physics, Zagreb (Croatia); Tercek, V [Clinical Hospital Sisters of Mercy, Health Physics Department, Zagreb (Croatia)

    1997-12-31

    In order to establish the Quality Criteria for diagnostic radiographic images in the radiology departments in Republic of Croatia we have started the several Quality Control projects on the field. The measurements are performed according to some methodology recommendations in our law but the methodology, measurement principles, measurement equipment, phantoms, measurable parameters for the good use by radiographers, statistical and numerical evaluation, dosimetric philosophy etc. where first recognized as a private/or group hazard of each person involved in the procedure of evaluation of diagnostic radiology images/diagnosis. The important quality elements of the imaging process are: the diagnostic quality of the radiographic image, the radiation dose to the patient and the choice of the radiographic technique. This depends on the x-ray unit (tube) radiation quality, image processing quality and final image evaluation quality. In this paper we will show how the Quality Control measurements can be easily connected to the dose delivered to the patient for the known diagnostic procedure and how this can be used by radiographers in their daily work. The reproducibility of the x-ray generator was checked before the service calibration and after the service calibration. The table of kV dependence and output dose per mAs was calculated and the ESD (entrance surface dose) was measured/calculated for the specific diagnostic procedure. After the phantom calculation were made and the dose prediction for the given procedure was done, measurements were done on the patients (digital dosemeters, TLD and film dosemeter combinations). We are claiming that there is no need to measure each patient if the proper Quality Control measurements are done and the proper table of ESD for each particular x-ray tube in diagnostic departments is calculated for the radiographers daily use. (author). 1 example, 1 fig., 13 refs.

  9. Wastewater treatment

    Directory of Open Access Journals (Sweden)

    Ranđel N. Kitanović

    2013-10-01

    Full Text Available Quality of life on Earth in the future will largely depend on the amount of safe water. As the most fundamental source of life, water is relentlessly consumed and polluted. To halt this trend, many countries are taking extensive measures and investing substantial resources in order to stop the contamination of water and return at least tolerably good water quality to nature. The goal of water purification is to obtain clean water with the sewage sludge as a by-product. Clean water is returned to nature, and further treatment of sludge may be subject to other procedures. The conclusion of this paper is simple. The procedure with purified water is easily achievable, purified water is discharged into rivers, lakes and seas, but the problem of further treatment of sludge remains. This paper presents the basic methods of wastewater treatment and procedures for processing the products from contaminated water. The paper can serve as a basis for further elaboration. Water Pollution In order to ensure normal life of living creatures, the water in which they live or the water they use must have a natural chemical composition and natural features. When, as a result of human activities, the chemical composition of water and the ratio of its chemical elements significantly change, we say that water is polluted. When the pollutants come from industrial plants, we are talking about industrial wastewater, and when they come from households and urban areas, we are talking about municipal wastewater. Both contain a huge amount of pollutants that eventually end up in rivers. Then, thousands of defenseless birds, fish and other animals suffer, and environmental consequences become immeasurable. In addition, the waste fed to the water often ends up in the bodies of marine animals, so they can return to us as food. Thermal water pollution also has multiple effects on the changes in the wildlife composition of aquatic ecosystems. Polluted water can be purified by

  10. Quality control in paediatric nuclear medicine

    International Nuclear Information System (INIS)

    Fischer, S.; Hahn, K.

    1997-01-01

    Nuclear medicine examinations in children require a maximum in quality. This is true for the preparation of the child and parents, the imaging procedure, processing and documentation. It is necessary that quality control through all steps is performed regularly. The aim must be that the children receive a minimum radiation dose, while there needs to be a high quality in imaging and clinical information from the study. Furthermore the child should not be too much psychologically affected by the nuclear medicine examination. (orig.) [de

  11. Quality Assurance and Quality Control in TLD Measurement

    International Nuclear Information System (INIS)

    Bhuiyan, S.I.; Qronfla, M.M.; Abulfaraj, W.H.; Kinsara, A.A.; Taha, T.M.; Molla, N.I.; Elmohr, S.M.

    2008-01-01

    TLD technique characterized by high precision and reproducibility of dose measurement is presented by addressing pre-readout annealing, group sorting, dose evaluation, blind tests, internal dose quality audit and external quality control audits. Two hundred and forty TLD chips were annealed for 1 hour at 4000 degree C followed by 2 h at 1000 degree C. After exposure of 1 mGy from 90 Sr irradiator TLDs were subjected to pre-readout annealing at 1000 degree C, then readout, sorted into groups each with nearly equal sensitivity. Upon repeating the procedures, TLDs having response >3.5% from group mean were dropped to assuring group stability. Effect of pre-readout annealing has been studied. Series of repeated measurements were conducted to stabilize calibration procedures and DCF generation using SSDL level 137 Cs calibrator, dose master, ionization chambers. Performed internal dose quality audits, blind tests and validated by external QC tests with King Abdulaziz City of Science and Technology

  12. Frontiers in statistical quality control 11

    CERN Document Server

    Schmid, Wolfgang

    2015-01-01

    The main focus of this edited volume is on three major areas of statistical quality control: statistical process control (SPC), acceptance sampling and design of experiments. The majority of the papers deal with statistical process control, while acceptance sampling and design of experiments are also treated to a lesser extent. The book is organized into four thematic parts, with Part I addressing statistical process control. Part II is devoted to acceptance sampling. Part III covers the design of experiments, while Part IV discusses related fields. The twenty-three papers in this volume stem from The 11th International Workshop on Intelligent Statistical Quality Control, which was held in Sydney, Australia from August 20 to August 23, 2013. The event was hosted by Professor Ross Sparks, CSIRO Mathematics, Informatics and Statistics, North Ryde, Australia and was jointly organized by Professors S. Knoth, W. Schmid and Ross Sparks. The papers presented here were carefully selected and reviewed by the scientifi...

  13. Quality control procedures in positron tomography

    International Nuclear Information System (INIS)

    Spinks, T.; Jones, T.; Heather, J.; Gilardi, M.

    1989-01-01

    The derivation of physiological parameters in positron tomography relies on accurate calibration of the tomograph. Normally, the calibration relates image pixel count density to the count rate from an external blood counter per unit activity concentration in each device. The quality control of the latter is simple and relies on detector stability assessed by measurement of a standard source of similar geometry to a blood sample. The quality control of the tomographic data depends on (i) detector stability, (ii) uniformity of calibration and normalisation sources and (iii) reproducibility of the attenuation correction procedure. A quality control procedure has been developed for an 8 detector ring (15 transaxial plane) tomograph in which detector response is assessed by acquiring data from retractable transmission ring sources. These are scanned daily and a print out of detector efficiencies is produced as well as changes from a given data. This provides the raw data from which decisions on recalibration or renormalisation are made. (orig.)

  14. Quality control of the activity meter

    International Nuclear Information System (INIS)

    Rodrigues, Marlon da Silva Brandão; Sá, Lídia Vasconcelos de

    2017-01-01

    Objective: To carry out a comparative analysis of national and international standards regarding the quality control of the activity meter used in Nuclear Medicine Services in Brazil. Material and methods: Quality control protocols from the International Atomic Energy Agency (IAEA), American Association of Physicists in Medicine (AAPM) and International Electrotechnical Commission (IEC) were pointed out and compared with requirements from both regulatory Brazilian agencies, National Surveillance Agency (ANVISA) and National Nuclear Energy Commission (CNEN). Results: The daily routine tests recommended by the regulatory agencies do not have significant differences; in contrast the tests with higher periodicities like (accuracy, linearity and precision) have differences discrepant. Conclusion: In view of the comparative analysis carried out, it is suggested that the national recommendations for the quality control tests of the activity meter should be checked and evaluated, with emphasis on the semiannual and annual periodicity tests. (author)

  15. Quality control of 11C-carfentanil

    International Nuclear Information System (INIS)

    Zhang Xiaojun; Zhang Jinming; Tian Jiahe; Xiang Xiaohui

    2013-01-01

    To study the quality control of 11 C-Carfentanil injection, physical, chemical and biological identification were used. The chemical and radiochemical purity of 11 C-Carfentanil Injection were detected by HPLC and Flower Count system; measured the quantity of product by LC-MS, specific activity was calculated later; The PTS was used to detect endotoxin, and other quality control methods were put up to guarantee the security of its clinical application. The produce appeared colorless and transparent, the radiochemical purity was more than 98%, content of the endotoxin was less than 5 EU/mL. The result showed that 11 C-Carfentanil injection had fulfilled pharmaceutical quality control request and could be applied safely to animal experiment and clinical diagnosis. (authors)

  16. Protein quality control in the nucleus

    DEFF Research Database (Denmark)

    Nielsen, Sofie V.; Poulsen, Esben Guldahl; Rebula, Caio A.

    2014-01-01

    to aggregate, cells have evolved several elaborate quality control systems to deal with these potentially toxic proteins. First, various molecular chaperones will seize the misfolded protein and either attempt to refold the protein or target it for degradation via the ubiquitin-proteasome system...... to be particularly active in protein quality control. Thus, specific ubiquitin-protein ligases located in the nucleus, target not only misfolded nuclear proteins, but also various misfolded cytosolic proteins which are transported to the nucleus prior to their degradation. In comparison, much less is known about...... these mechanisms in mammalian cells. Here we highlight recent advances in our understanding of nuclear protein quality control, in particular regarding substrate recognition and proteasomal degradation....

  17. The Study on quality control of nuclear power installation project

    International Nuclear Information System (INIS)

    Wu Jie

    2008-01-01

    The quality planning, quality assurance and quality control are discussed by applying the quality control (QC) theory and combining the real situation of the Qinshan II project. This paper is practical and plays an active role in instruction of project quality control by applying the above QC theory and control techniques. (authors)

  18. A quality control program for radiation sources

    International Nuclear Information System (INIS)

    Almeida, C.E. de; Sibata, C.H.; Cecatti, E.R.; Kawakami, N.S.; Alexandre, A.C.; Chiavegatti Junior, M.

    1982-01-01

    An extensive quality control program was established covering the following areas: physical parameters of the therapeutical machines, dosimetric standards, preventive maintenance of radiation sources and measuring instruments. A critical evaluation of this program was done after two years (1977-1979) of routine application and the results will be presented. The fluctuation on physical parameters strongly supports the efforts and cost of a quality control program. This program has certainly improved the accuracy required on the delivery of the prescribed dose for radiotherapy treatment. (Author) [pt

  19. Quality control of nuclear medicine instruments 1991

    International Nuclear Information System (INIS)

    1991-05-01

    This document gives detailed guidance on the quality control of various instruments used in nuclear medicine. A first preliminary document was drawn up in 1979. A revised and extended version, incorporating recommended procedures, test schedules and protocols was prepared in 1982. The first edition of ''Quality Control of Nuclear Medicine Instruments'', IAEA-TECDOC-317, was printed in late 1984. Recent advances in the field of nuclear medicine imaging made it necessary to add a chapter on Camera-Computer Systems and another on SPECT Systems. Figs and tabs

  20. Quality control of nuclear medicine instruments, 1991

    International Nuclear Information System (INIS)

    1996-12-01

    This document gives detailed guidance on the quality control of various instruments used in nuclear medicine. A first preliminary document was drawn up in 1979. A revised and extended version, incorporating recommended procedures, test schedules and protocols was prepared in 1982. The first edition of 'Quality Control of Nuclear Medicine Instruments', IAEA-TECDOC-317, was printed in late 1984. Recent advances in the field of nuclear medicine imaging made it necessary to add a chapter on Camera-Computer Systems and another on SPECT Systems

  1. HPLC for quality control of polyimides

    Science.gov (United States)

    Young, P. R.; Sykes, G. F.

    1979-01-01

    High Pressure Liquid Chromatography (HPLC) as a quality control tool for polyimide resins and prepregs are presented. A data base to help establish accept/reject criteria for these materials was developed. This work is intended to supplement, not replace, standard quality control tests normally conducted on incoming resins and prepregs. To help achieve these objectives, the HPLC separation of LARC-160 polyimide precursor resin was characterized. Room temperature resin aging effects were studied. Graphite reinforced composites made from fresh and aged resin were fabricated and tested to determine if changes observed by HPLC were significant.

  2. Statistical quality control a loss minimization approach

    CERN Document Server

    Trietsch, Dan

    1999-01-01

    While many books on quality espouse the Taguchi loss function, they do not examine its impact on statistical quality control (SQC). But using the Taguchi loss function sheds new light on questions relating to SQC and calls for some changes. This book covers SQC in a way that conforms with the need to minimize loss. Subjects often not covered elsewhere include: (i) measurements, (ii) determining how many points to sample to obtain reliable control charts (for which purpose a new graphic tool, diffidence charts, is introduced), (iii) the connection between process capability and tolerances, (iv)

  3. Technical quality control - constancy controls for digital mammography systems

    International Nuclear Information System (INIS)

    Pedersen, K.; Landmark, I.D.; Bredholt, K.; Hauge, I.H.R.

    2009-04-01

    To ensure the quality of mammographic images, so-called constancy control tests are performed frequently. The report contains a programme for constancy control of digital mammography systems, encompassing the mammography unit, computed radiography (CR) systems, viewing conditions and displays, printers, and procedures for data collection for patient dose calculations. (Author)

  4. Wastewater Treatment

    Science.gov (United States)

    ... day before releasing it back to the environment. Treatment plants reduce pollutants in wastewater to a level nature can handle. Wastewater is used water. It includes substances such as human waste, food ...

  5. Nitrogen Control Through Decentralized Wastewater Treatment: Process Performance and Alternative Management Strategies

    Science.gov (United States)

    Decentralized or onsite wastewater treatment (OWT) systems have long been implicated in being a major source of N inputs to surface and ground waters and numerous regulatory bodies have promulgated strict total N (TN) effluent standards in N-sensitive areas. These standards, howe...

  6. Optimization of Urban Wastewater Systems using Model Based Design and Control

    NARCIS (Netherlands)

    Velez Quintero, C.A.

    2012-01-01

    In this research a considerable amount of scientific evidence had been collected which leads to the conclusion that the urban wastewater components should be designed as one integrated system, if the protection of the receiving waters is to be achieved cost-effectively. Even more, there is a need

  7. Control cards as a statistical quality control resource

    Directory of Open Access Journals (Sweden)

    Aleksandar Živan Drenovac

    2013-02-01

    Full Text Available Normal 0 false false false MicrosoftInternetExplorer4 This paper proves that applying of statistical methods can significantly contribute increasing of products and services quality, as well as increasing of institutions rating. Determining of optimal, apropos anticipatory and limitary values, is based on sample`s statistical analyze. Control cards represent very confident instrument, which is simple for use and efficient for control of process, by which process is maintained in set borders. Thus, control cards can be applied in quality control of procesess of weapons and military equipment production, maintenance of technical systems, as well as for seting of standards and increasing of quality level for many other activities.

  8. A Comparison of Power Quality Controllers

    Directory of Open Access Journals (Sweden)

    Petr Černek

    2012-01-01

    Full Text Available This paper focuses on certain types of FACTS (Flexibile AC Transmission System controllers, which can be used for improving the power quality at the point of connection with the power network. It focuses on types of controllers that are suitable for use in large buildings, rather than in transmission networks. The goal is to compare the features of the controllers in specific tasks, and to clarify which solution is best for a specific purpose. It is in some cases better and cheaper to use a combination of controllers than a single controller. The paper also presents the features of a shunt active harmonic compensator, which is a very modern power quality controller that can be used in many cases, or in combination with other controllers. The comparison was made using a matrix diagram that, resulted from mind mapsand other analysis tools. The paper should help engineers to choose the best solution for improving the power quality in a specific power network at distribution level.

  9. Olive mill wastewater triggered changes in physiology and nutritional quality of tomato (Lycopersicon esculentum mill) depending on growth substrate.

    Science.gov (United States)

    Ouzounidou, G; Asfi, M; Sotirakis, N; Papadopoulou, P; Gaitis, F

    2008-10-30

    We have studied the changes in the physiology and nutritional quality of Lycopersicon esculentum exposed to olive mill wastewater (OMW) with regard to cultivation in sand and soil. Tomato plant performance decreased with increasing concentration of OMW to both substrates. Root was more sensitive to OMW than the upper parts of the plants, grown either in sand or in soil for 10 days and 3 months, respectively, probably due to the direct OMW toxicity on roots as compared to other parts. Significant restriction on uptake and translocation of nutrients (K, Na, Fe, Ca and Mg) under OMW application was found. The decrease in the photochemical efficiency of PSII photochemistry in the light adapted state and the big decrease in photochemical quenching, indicate that OMW resulted in diminished reoxidation of Q(A)(-) and started to inactivate the reaction centers of PSII. The OMW supply on soil and sand, resulted in leaf water stress and lesser water use efficiency. Plants treated with high OMW concentration, produced fewer but bigger tomatoes as compared to plants treated with lower OMW concentration. Generally, fruit yield and nutritional value was inhibited under OMW application.

  10. Data Organization for Quality Control Test

    International Nuclear Information System (INIS)

    Yahaya Talib; Glam Hadzir Patai Mohamad; Wan Hamirul Bahrin Wan Kamal

    2011-01-01

    Test data and results for quality control of Mo-99/ Tc-99m generator shall be organized properly. A computer program was developed using Visual Basic 6.0 to process test data, store data and results to specific folder, generate test reports and certificates. Its performance has been evaluated and tested. (author)

  11. Water quality control program in experimental circuits

    International Nuclear Information System (INIS)

    Cegalla, Miriam A.

    1996-01-01

    The Water Quality Control Program of the Experimental Circuits visualizes studying the water chemistry of the cooling in the primary and secondary circuits, monitoring the corrosion of the systems and studying the mechanism of the corrosion products transport in the systems. (author)

  12. Studies of quality control procedures for radiopharmaceuticals

    International Nuclear Information System (INIS)

    Zivanovic, M.; Trott, N.G.

    1983-01-01

    In this paper, a short description is given of a radiopharmaceutical preparation suite set up at the Royal Marsden Hospital and an account is presented of methods used for quality control of radiopharmaceuticals and of the results obtained over a period of about two and a half years

  13. Materials, methods and quality control, ch. 3

    International Nuclear Information System (INIS)

    Vader, H.L.

    1978-01-01

    A description of the chemical reagents, the 125 I-labelled angiotensin I, the antiserum and the standards is given. A modified measuring method with the New England Nuclear kit for angiotensin I radioimmunoassay is presented as well as the quality control data

  14. Guidelines for radriopharmaceutical quality control in hospitals

    International Nuclear Information System (INIS)

    Welsh, W.J.

    1982-01-01

    This document has been prepared to assist hospital administrators in ensuring that adequate quality control is performed on radiopharmaceuticals administered to their patients. Three sets of guidelines are presented, the degree of sophistication being dependent on the amount of hospital involvement in the radiopharmaceutical preparation

  15. Quality Control Of Selected Pesticides With GC

    Energy Technology Data Exchange (ETDEWEB)

    Karasali, H. [Benaki Phytopathological Institute Laboratory of Physical and Chemical Analysis of Pesticides, Ekalis (Greece)

    2009-07-15

    The practical quality control of selected pesticides with GC is treated. Detailed descriptions are given on materials and methods used, including sample preparation and GC operating conditions. The systematic validation of multi methods is described, comprising performance characteristics in routine analysis, like selectivity, specificity etc. This is illustrated by chromatograms, calibration curves and tables derived from real laboratory data. (author)

  16. Outsourcing University Degrees: Implications for Quality Control

    Science.gov (United States)

    Edwards, Julie; Crosling, Glenda; Edwards, Ron

    2010-01-01

    Education institutions worldwide have and continue to seek opportunities to spread their offerings abroad. While the provision of courses to students located overseas through partner institutions has many advantages, it raises questions about quality control that are not as applicable to other forms of international education. This paper uses a…

  17. 77 FR 1687 - EPA Workshops on Achieving Water Quality Through Integrated Municipal Stormwater and Wastewater...

    Science.gov (United States)

    2012-01-11

    ... quality benefits and consider various innovative approaches, such as green infrastructure, that may be... approach, EPA encourages municipalities to pursue more innovative approaches such as green infrastructure technologies and asset management or similar utility-wide planning approaches. EPA has strongly encouraged...

  18. Instruments for integrated water resources management : water quality modeling for sustainable wastewater management

    NARCIS (Netherlands)

    Barjoveanu, George; Teodosiu, Carmen; Cojocariu, Claudia; Augustijn, Dionysius C.M.; Craciun, Ioan

    2013-01-01

    This study presents the development and use of a hydraulic-coupled water quality model for the simulation of Biochemical Oxygen Demand (BOD) concentrations in the Bahlui River, a small river located in northeastern Romania. This river experiences the typical pollution problems for many Romanian

  19. The role and relevance of quality assurance to quality control

    International Nuclear Information System (INIS)

    Churchill, G.F.

    1989-01-01

    The paper describes the development of Quality Assurance as a total management technique, incorporating manufacturing and construction Quality Control, to give confidence of satisfactory in-service performance. The application of QA to the Heysham 2 and Torness AGR projects design and construction is defined with particular reference to the development of a QA requirements specification, delegation of QA responsibility through the hierarchy of purchasers and suppliers of plant and material, the role of the QA organization and QA auditing. The paper discusses the effectiveness and benefits of QA and the problems identified in its application and implementation. The problems, their solutions and longer term improvements to reduce the costs of QA as well as enhancing confidence in the satisfactory performance of future nuclear projects, are described. (author)

  20. Quality control of PET/CT

    International Nuclear Information System (INIS)

    Angelova, J.; Zajcharov, M.

    2013-01-01

    Full text: Introduction: The aim of this work is to undertake a review of the methods for checking and adjusting the computer and positron emission tomography in the Hospital 'Alexandrovska' by the attached to the equipment phantoms according to the manufacturer prescription in order to fulfill its requirements for the entry of the main parameters image within certain limits. Materials and Methods: At the start of work a check of the lasers setting for patient positioning and 'heat' of the X-ray tube scanner to better image quality were made. Daily verification procedures on the image quality of CT through the water phantom and weekly - 'air' calibration were carried out. In positron part, daily control involves setting the resolution and sensitivity of the scanner through built Ga68 phantom. When commissioning, after repair and at least once a year, it is necessary to verify the accuracy of registration of the pulses from the crystal with a water phantom of known volume and the coincidence between CT and PET image. Results: The process of quality control is interactive. The results are displayed in tables and graphically, with the goal the individual values to fall within the determined by manufacturers range and to meet the standards for image quality. If necessary, the procedure repeats several times until it is fulfilled. Conclusion: Ensuring the quality of the image in positron emission tomography combined with computed tomography, is inextricably linked to accurate and precise diagnosis of tumor processes in the human body

  1. Quality assurance and quality control of nuclear engineering during construction phase

    International Nuclear Information System (INIS)

    Zhang Zhihua; Deng Yue; Liu Yaoguang; Xu Xianqi; Zhou Shan; Qian Dazhi; Zhang Yang

    2007-01-01

    The quality assurance (QA) and quality control (QC) is a very important work in the nuclear engineering. This paper starts with how to establish quality assurance system of nuclear engineering construction phase, then introduces several experiments and techniques such as the implementation of quality assurance program, the quality assurance and quality control of contractors, the quality surveillance and control of supervisory companies, quality assurance audit and surveillance of builders. (authors)

  2. Internal quality control: planning and implementation strategies.

    Science.gov (United States)

    Westgard, James O

    2003-11-01

    The first essential in setting up internal quality control (IQC) of a test procedure in the clinical laboratory is to select the proper IQC procedure to implement, i.e. choosing the statistical criteria or control rules, and the number of control measurements, according to the quality required for the test and the observed performance of the method. Then the right IQC procedure must be properly implemented. This review focuses on strategies for planning and implementing IQC procedures in order to improve the quality of the IQC. A quantitative planning process is described that can be implemented with graphical tools such as power function or critical-error graphs and charts of operating specifications. Finally, a total QC strategy is formulated to minimize cost and maximize quality. A general strategy for IQC implementation is recommended that employs a three-stage design in which the first stage provides high error detection, the second stage low false rejection and the third stage prescribes the length of the analytical run, making use of an algorithm involving the average of normal patients' data.

  3. Biogas-pH automation control strategy for optimizing organic loading rate of anaerobic membrane bioreactor treating high COD wastewater.

    Science.gov (United States)

    Yu, Dawei; Liu, Jibao; Sui, Qianwen; Wei, Yuansong

    2016-03-01

    Control of organic loading rate (OLR) is essential for anaerobic digestion treating high COD wastewater, which would cause operation failure by overload or less efficiency by underload. A novel biogas-pH automation control strategy using the combined gas-liquor phase monitoring was developed for an anaerobic membrane bioreactor (AnMBR) treating high COD (27.53 g·L(-1)) starch wastewater. The biogas-pH strategy was proceeded with threshold between biogas production rate >98 Nml·h(-1) preventing overload and pH>7.4 preventing underload, which were determined by methane production kinetics and pH titration of methanogenesis slurry, respectively. The OLR and the effluent COD were doubled as 11.81 kgCOD·kgVSS(-1)·d(-1) and halved as 253.4 mg·L(-1), respectively, comparing with a constant OLR control strategy. Meanwhile COD removal rate, biogas yield and methane concentration were synchronously improved to 99.1%, 312 Nml·gCODin(-1) and 74%, respectively. Using the biogas-pH strategy, AnMBR formed a "pH self-regulation ternary buffer system" which seizes carbon dioxide and hence provides sufficient buffering capacity. Copyright © 2015 Elsevier Ltd. All rights reserved.

  4. A review on the use of membrane technology and fouling control for olive mill wastewater treatment.

    Science.gov (United States)

    Pulido, Javier Miguel Ochando

    2016-09-01

    Olive mill effluents (OME) by-produced have significantly increased in the last decades as a result of the boost of the olive oil agro-industrial sector and due to the conversion into continuous operation centrifugation technologies. In these effluents, the presence of phytotoxic recalcitrant pollutants makes them resistant to biological degradation and thus inhibits the efficiency of biological and conventional processes. Many reclamation treatments as well as integrated processes for OME have already been proposed and developed but not led to completely satisfactory and cost-effective results. Olive oil industries in its current status, typically small mills dispersed, cannot afford such high treatment costs. Furthermore, conventional treatments are not able to abate the significant dissolved monovalent and divalent ions concentration present in OME. Within this framework, membrane technology offers high efficiency and moderate investment and maintenance expenses. Wastewater treatment by membrane technologies is growing in the recent years. This trend is owed to the fact of the availability of new membrane materials, membrane designs, membrane module concepts and general know-how, which have promoted credibility among investors. However, fouling reduces the membrane performances in time and leads to premature substitution of the membrane modules, and this is a problem of cost efficiency since wastewater treatment must imply low operating costs. Appropriate fouling inhibition methods should assure this result, thus making membrane processes for wastewater stream treatment both technically and economically feasible. In this paper, the treatment of the effluents by-produced in olive mills, generally called olive mill wastewaters, will be addressed. Within this context, the state of the art of the different pretreatments and integral membrane processes proposed up to today will be gathered and discussed, with an insight in the problem of fouling. Copyright © 2015

  5. Formation and Control of N-Nitrosodimethylamine (NDMA) in Wastewater Reclaimed for Indirect Potable Reuse

    OpenAIRE

    Sgroi, Massimiliano

    2014-01-01

    A large variety of disinfection by-products (DBPs) are formed during water treatment processes using chlorination. Disinfection with chloramines is often used to significantly reduce the formation of regulated DBPs. However, chloramination favours the formation of N-nitrosamines, which are emerging by-products of health concern. Of all the nitrosamines, N-nitrosodimethylamine (NDMA) has been most commonly detected in drinking water and wastewater. Nitrosamines can also be produced using diffe...

  6. Thermochemical Wastewater Valorization via Enhanced Microbial Toxicity Tolerance

    Energy Technology Data Exchange (ETDEWEB)

    Beckham, Gregg T [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Thelhawadigedara, Lahiru Niroshan Jayakody [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Johnson, Christopher W [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Pleitner, Brenna P [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Cleveland, Nicholas S [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Michener, William E [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Olstad-Thompson, Jessica L [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Vardon, Derek R [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Whitham, Jason M. [Oak Ridge National Laboratory; Giannone, Richard J. [Oak Ridge National Laboratory; Klingeman, Dawn M. [Oak Ridge National Laboratory; Brown, Robert C. [Iowa State University; Brown, Steven D. [Oak Ridge National Laboratory; LanzaTech, Inc.; Hettich, Robert L. [Oak Ridge National Laboratory; Guss, Adam M. [Oak Ridge National Laboratory

    2018-04-17

    Thermochemical (TC) biomass conversion processes such as pyrolysis and liquefaction generate considerable amounts of wastewater, which often contains highly toxic compounds that are incredibly challenging to convert via standard wastewater treatment approaches such as anaerobic digestion. These streams represent a cost for TC biorefineries, and a potential valorization opportunity, if effective conversion methods are developed. The primary challenge hindering microbial conversion of TC wastewater is toxicity. In this study, we employ a robust bacterium, Pseudomonas putida, with TC wastewater streams to demonstrate that aldehydes are the most inhibitory compounds in these streams. Proteomics, transcriptomics, and fluorescence-based immunoassays of P. putida grown in a representative wastewater stream indicate that stress results from protein damage, which we hypothesize is a primary toxicity mechanism. Constitutive overexpression of the chaperone genes, groEL, groES, and clpB, in a genome-reduced P. putida strain improves the tolerance towards multiple TC wastewater samples up to 200-fold. Moreover, the concentration ranges of TC wastewater are industrially relevant for further bioprocess development for all wastewater streams examined here, representing different TC process configurations. Furthermore, we demonstrate proof-of-concept polyhydroxyalkanoate production from the usable carbon in an exemplary TC wastewater stream. Overall, this study demonstrates that protein quality control machinery and repair mechanisms can enable substantial gains in microbial tolerance to highly toxic substrates, including heterogeneous waste streams. When coupled to other metabolic engineering advances such as expanded substrate utilization and enhanced product accumulation, this study generally enables new strategies for biological conversion of highly-toxic, organic-rich wastewater via engineered aerobic monocultures or designer consortia.

  7. Quality and Control of Water Vapor Winds

    Science.gov (United States)

    Jedlovec, Gary J.; Atkinson, Robert J.

    1996-01-01

    Water vapor imagery from the geostationary satellites such as GOES, Meteosat, and GMS provides synoptic views of dynamical events on a continual basis. Because the imagery represents a non-linear combination of mid- and upper-tropospheric thermodynamic parameters (three-dimensional variations in temperature and humidity), video loops of these image products provide enlightening views of regional flow fields, the movement of tropical and extratropical storm systems, the transfer of moisture between hemispheres and from the tropics to the mid- latitudes, and the dominance of high pressure systems over particular regions of the Earth. Despite the obvious larger scale features, the water vapor imagery contains significant image variability down to the single 8 km GOES pixel. These features can be quantitatively identified and tracked from one time to the next using various image processing techniques. Merrill et al. (1991), Hayden and Schmidt (1992), and Laurent (1993) have documented the operational procedures and capabilities of NOAA and ESOC to produce cloud and water vapor winds. These techniques employ standard correlation and template matching approaches to wind tracking and use qualitative and quantitative procedures to eliminate bad wind vectors from the wind data set. Techniques have also been developed to improve the quality of the operational winds though robust editing procedures (Hayden and Veldon 1991). These quality and control approaches have limitations, are often subjective, and constrain wind variability to be consistent with model derived wind fields. This paper describes research focused on the refinement of objective quality and control parameters for water vapor wind vector data sets. New quality and control measures are developed and employed to provide a more robust wind data set for climate analysis, data assimilation studies, as well as operational weather forecasting. The parameters are applicable to cloud-tracked winds as well with minor

  8. Cell-based metabolomics approach for assessing the impact of wastewater treatment plant effluent on downstream water quality

    Science.gov (United States)

    Wastewater treatment plants (WWTP) are a known source of various types of chemicals including pharmaceuticals and personal care products (PPCPs), naturally occurring hormones, and pesticides. There is great concern regarding their adverse effects on human and ecological health th...

  9. Control and Prevention of Wastewater Pollution From Amerya Petroleum Refining Company

    International Nuclear Information System (INIS)

    Bakry, A.A.

    2004-01-01

    An oil refinery normally uses large quantities of water, for cooling and other process purpose. This water is treated from contaminants and finally returned to a lake or sea, outside the refinery. Amerya Petroleum Refining Company (APRC) uses conventional and special treatment methods for wastewater to remove all pollutants and to reduce the oil content in refinery final effluent water to a limit of 10 ppm , as the maximum permissible limit for environmental protection as designated by the Egyptian Act No.4 for the year 1994 . About 80% of oil in wastewater is separated by API (American Petroleum Institute) separator method and returned to refinery. Small oil droplets, emulsion and suspended matter escaped from API separator but were removed successfully in the dissolved air flotation (DAF) with chemical additives as the secondary treatment stage for wastewater. The flotation method with chemical additives and filtration were used to reduce the suspended solids and oil content to permissible levels (10 ppm) Furthermore, biological treatment unit was constructed to remove the dissolved oxygen consuming contaminates, e.g. phenolic compounds and traces of hydrocarbon derivatives. It was found that the BOD and COD of the effluent were reduced, and 100% removal of the trace amount of phenol was achieved in effluent

  10. Monitoring and control of UV and UV-TiO{sub 2} disinfections for municipal wastewater reclamation using artificial neural networks

    Energy Technology Data Exchange (ETDEWEB)

    Lin, Chuang-Hung [Department of Architecture, National United University, Miao-Li 360, Taiwan, ROC (China); Yu, Ruey-Fang, E-mail: rfyu@nuu.edu.tw [Department of Safety, Health and Environmental Engineering, National United University, Miao-Li 360, Taiwan, ROC (China); Cheng, Wen-Po; Liu, Chun-Ru [Department of Safety, Health and Environmental Engineering, National United University, Miao-Li 360, Taiwan, ROC (China)

    2012-03-30

    Highlights: Black-Right-Pointing-Pointer ANN models can effectively control both UV and UV-TiO{sub 2} disinfections for wastewater reuse. Black-Right-Pointing-Pointer Comparing to UV disinfection, UV-TiO{sub 2} disinfection can save 13.2-15.7% of UV dosage and capacity. Black-Right-Pointing-Pointer SS decreases disinfection efficiency when UV doses were <10,000 {mu}W s/cm{sup 2}. - Abstract: The use of ultraviolet (UV) irradiation as a physical wastewater disinfection has increased in recent years, especially for wastewater reuse. The UV-TiO{sub 2} can generate OH radicals, which is highly effective to inactivate microorganisms in wastewater disinfection. However, both UV and UV-TiO{sub 2} disinfections create multiple physical, chemical, and bio-chemical phenomena that affect their germicidal efficiency. It is difficult to build a precise control model using existing mathematic models. This study applies artificial neural network (ANN) models to control UV and UV-TiO{sub 2} disinfections. Experimental results indicate that the ANN models, which precisely generate relationships among multiple monitored parameters, total coliform counts in influent and effluent, and UV doses, can be used as control models for UV and UV-TiO{sub 2} disinfections. A novel ANN control strategy is applied to control UV and UV-TiO{sub 2} disinfection processes to meet three total coliform count limits for three wastewater reuse purposes. The proposed controlled strategy effectively controls UV and UV-TiO{sub 2} disinfection, resulting in acceptable total coliform counts in effluent for the three wastewater reuse purposes. The required UV doses for UV-TiO{sub 2} disinfection were lower than those for UV disinfection, resulting in energy saving and capacity reduction of 13.2-15.7%.

  11. 42 CFR 84.40 - Quality control plans; filing requirements.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Quality control plans; filing requirements. 84.40... Control § 84.40 Quality control plans; filing requirements. As a part of each application for approval or... proposed quality control plan which shall be designed to assure the quality of respiratory protection...

  12. 21 CFR 211.22 - Responsibilities of quality control unit.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 4 2010-04-01 2010-04-01 false Responsibilities of quality control unit. 211.22... Personnel § 211.22 Responsibilities of quality control unit. (a) There shall be a quality control unit that... have been fully investigated. The quality control unit shall be responsible for approving or rejecting...

  13. 30 CFR 28.30 - Quality control plans; filing requirements.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Quality control plans; filing requirements. 28... PROTECTION FOR TRAILING CABLES IN COAL MINES Quality Control § 28.30 Quality control plans; filing... part, each applicant shall file with MSHA a proposed quality control plan which shall be designed to...

  14. Quality Controlling CMIP datasets at GFDL

    Science.gov (United States)

    Horowitz, L. W.; Radhakrishnan, A.; Balaji, V.; Adcroft, A.; Krasting, J. P.; Nikonov, S.; Mason, E. E.; Schweitzer, R.; Nadeau, D.

    2017-12-01

    As GFDL makes the switch from model development to production in light of the Climate Model Intercomparison Project (CMIP), GFDL's efforts are shifted to testing and more importantly establishing guidelines and protocols for Quality Controlling and semi-automated data publishing. Every CMIP cycle introduces key challenges and the upcoming CMIP6 is no exception. The new CMIP experimental design comprises of multiple MIPs facilitating research in different focus areas. This paradigm has implications not only for the groups that develop the models and conduct the runs, but also for the groups that monitor, analyze and quality control the datasets before data publishing, before their knowledge makes its way into reports like the IPCC (Intergovernmental Panel on Climate Change) Assessment Reports. In this talk, we discuss some of the paths taken at GFDL to quality control the CMIP-ready datasets including: Jupyter notebooks, PrePARE, LAMP (Linux, Apache, MySQL, PHP/Python/Perl): technology-driven tracker system to monitor the status of experiments qualitatively and quantitatively, provide additional metadata and analysis services along with some in-built controlled-vocabulary validations in the workflow. In addition to this, we also discuss the integration of community-based model evaluation software (ESMValTool, PCMDI Metrics Package, and ILAMB) as part of our CMIP6 workflow.

  15. Water-quality characteristics and trends for selected wells possibly influenced by wastewater disposal at the Idaho National Laboratory, Idaho, 1981-2012

    Science.gov (United States)

    Davis, Linda C.; Bartholomay, Roy C.; Fisher, Jason C.; Maimer, Neil V.

    2015-01-01

    The U.S. Geological Survey, in cooperation with the U.S. Department of Energy, analyzed water-quality data collected from 64 aquifer wells and 35 perched groundwater wells at the Idaho National Laboratory (INL) from 1981 through 2012. The wells selected for the study were wells that possibly were affected by wastewater disposal at the INL. The data analyzed included tritium, strontium-90, major cations, anions, nutrients, trace elements, total organic carbon, and volatile organic compounds. The analyses were performed to examine water-quality trends that might influence future management decisions about the number of wells to sample at the INL and the type of constituents to monitor.

  16. Determination and evaluation of air quality control. Manual of ambient air quality control in Germany

    Energy Technology Data Exchange (ETDEWEB)

    Lahmann, E.

    1997-07-01

    Measurement of air pollution emissions and ambient air quality are essential instruments for air quality control. By undertaking such measurements, pollutants are registered both at their place of origin and at the place where they may have an effect on people or the environment. Both types of measurement complement each other and are essential for the implementation of air quality legislation, particularly, in compliance with emission and ambient air quality limit values. Presented here are similar accounts of measurement principles and also contains as an Appendix a list of suitability-tested measuring devices which is based on information provided by the manufacturers. In addition, the guide of ambient air quality control contains further information on discontinuous measurement methods, on measurement planning and on the assessment of ambient air quality data. (orig./SR)

  17. Control of Bank Consolidated Financial Statements Quality

    Directory of Open Access Journals (Sweden)

    Margarita S. Ambarchyan

    2013-01-01

    Full Text Available The author presents the multiple linear regression model of bank consolidated financial statements quality. The article considers six characteristics that can be used to estimate the level of bank consolidated financial statements quality. The multiple linear regression model was developed, using the results of point-based system of consolidated financial statements of thirty European bank and financial groups on the basis of the developed characteristics. The author offers to use the characteristic significance factor in the process of consolidated financial statements appraisal by points. The constructed regression model is checked on accuracy and statistical significance. The model can be used by internal auditors and financial analytics as an instrument for bank and non-bank consolidated financial statements quality control

  18. Quality Risk Management: Putting GMP Controls First.

    Science.gov (United States)

    O'Donnell, Kevin; Greene, Anne; Zwitkovits, Michael; Calnan, Nuala

    2012-01-01

    This paper presents a practical way in which current approaches to quality risk management (QRM) may be improved, such that they better support qualification, validation programs, and change control proposals at manufacturing sites. The paper is focused on the treatment of good manufacturing practice (GMP) controls during QRM exercises. It specifically addresses why it is important to evaluate and classify such controls in terms of how they affect the severity, probability of occurrence, and detection ratings that may be assigned to potential failure modes or negative events. It also presents a QRM process that is designed to directly link the outputs of risk assessments and risk control activities with qualification and validation protocols in the GMP environment. This paper concerns the need for improvement in the use of risk-based principles and tools when working to ensure that the manufacturing processes used to produce medicines, and their related equipment, are appropriate. Manufacturing processes need to be validated (or proven) to demonstrate that they can produce a medicine of the required quality. The items of equipment used in such processes need to be qualified, in order to prove that they are fit for their intended use. Quality risk management (QRM) tools can be used to support such qualification and validation activities, but their use should be science-based and subject to as little subjectivity and uncertainty as possible. When changes are proposed to manufacturing processes, equipment, or related activities, they also need careful evaluation to ensure that any risks present are managed effectively. This paper presents a practical approach to how QRM may be improved so that it better supports qualification, validation programs, and change control proposals in a more scientific way. This improved approach is based on the treatment of what are called good manufacturing process (GMP) controls during those QRM exercises. A GMP control can be considered

  19. Impact of wastewater from the rural commune of Jmaa Moulblad on the physico-chemical quality of the waters of the Grou River (Rabat region, Morocco)

    Science.gov (United States)

    Arifi, Karim; Tahri, Latifa; El Abid, Abdallah; Hefiane, Fatima Zahra; Elblidi, Souad; Yahyaoui, Ahmed; Fekhaoui, Mohammed

    2018-05-01

    The Grou River is one of the main rivers that feed the reservoir of the Sidi Mohammed Ben Abdellah (SMBA) dam in Morocco. However, this river is particularly threatened by the pollution problem. It is in this context that this study aims to study the effect of wastewater from the rural commune of Jmaa Moulblad on the physicochemical quality of the waters of this river. We analyzed 11 physicochemical parameters (T° of area, T° of water, pH, EC, mV, Sal, TDS, BOD, COD, SS and TOC), with a monthly frequency since the month of December 2014 until November 2015. The results obtained show a worrying situation of the state of this watercourse. To remedy this problem, we recommend pre-treatment of wastewater before discharge and the implementation of a management plan and sustainable management of the Grou River watershed.

  20. Impact of wastewater from the rural commune of Jmaa Moulblad on the physico-chemical quality of the waters of the Grou River (Rabat region, Morocco

    Directory of Open Access Journals (Sweden)

    Arifi Karim

    2018-01-01

    Full Text Available The Grou River is one of the main rivers that feed the reservoir of the Sidi Mohammed Ben Abdellah (SMBA dam in Morocco. However, this river is particularly threatened by the pollution problem. It is in this context that this study aims to study the effect of wastewater from the rural commune of Jmaa Moulblad on the physicochemical quality of the waters of this river. We analyzed 11 physicochemical parameters (T° of area, T° of water, pH, EC, mV, Sal, TDS, BOD, COD, SS and TOC, with a monthly frequency since the month of December 2014 until November 2015. The results obtained show a worrying situation of the state of this watercourse. To remedy this problem, we recommend pre-treatment of wastewater before discharge and the implementation of a management plan and sustainable management of the Grou River watershed.

  1. Performance of a sequencing-batch membrane bioreactor (SMBR) with an automatic control strategy treating high-strength swine wastewater.

    Science.gov (United States)

    Sui, Qianwen; Jiang, Chao; Yu, Dawei; Chen, Meixue; Zhang, Junya; Wang, Yawei; Wei, Yuansong

    2018-01-15

    Due to high-strength of organic matters, nutrients and pathogen, swine wastewater is a major source of pollution to rural environment and surface water. A sequencing-batch membrane bioreactor (SMBR) system with an automatic control strategy was developed for high-strength swine wastewater treatment. Short-cut nitrification and denitrification (SND) was achieved at nitrite accumulation rate of 83.6%, with removal rates of COD, NH 4 + -N and TN at 95%, 99% and 93%, respectively, at reduced HRT of 6.0 d and TN loading rate of 0.02kgN/(kgVSS d). With effective membrane separation, the reduction of total bacteria (TB) and putative pathogen were 2.77 logs and 1%, respectively. The shift of microbial community was well responded to controlling parameters. During the SND process, ammonia oxidizing bacteria (AOB) (Nitrosomonas, Nitrosospira) and nitrite oxidizing bacteria (NOB) (Nitrospira) were enriched by 52 times and reduced by 2 times, respectively. The denitrifiers (Thauera) were well enriched and the diversity was enhanced. Copyright © 2017. Published by Elsevier B.V.

  2. Recent practices on wastewater reuse in Turkey.

    Science.gov (United States)

    Tanik, A; Ekdal, A; Germirli Babuna, F; Orhon, D

    2005-01-01

    Reuse of wastewater for irrigational purposes in agriculture has been a widely applied practice all around the world compared to such applications in industries. In most of the developing countries, high costs of wastewater treatment stimulate the direct reuse of raw or partly treated effluent in irrigation despite the socio-cultural objections in some countries regarding religious rituals towards consuming wastewater. In Turkey, reuse applications in agriculture have been in use by indirect application by means of withdrawing water from the downstream end of treatment plants. Such practices affected the deterioration of surface water resources due to the lack of water quality monitoring and control. However, more conscious and planned reuse activities in agriculture have recently started by the operation of urban wastewater treatment plants. Turkey does not face any severe water scarcity problems for the time being, but as the water resources show the signs of water quality deterioration it seems to be one of the priority issues in the near future. The industrial reuse activities are only at the research stage especially in industries consuming high amounts of water. In-plant control implementation is the preferred effort of minimizing water consumption in such industries. The current reuse activities are outlined in the article forming an example from a developing country.

  3. Assessment of wastewater and recycled water quality: a comparison of lines of evidence from in vitro, in vivo and chemical analyses.

    Science.gov (United States)

    Leusch, Frederic D L; Khan, Stuart J; Gagnon, M Monique; Quayle, Pam; Trinh, Trang; Coleman, Heather; Rawson, Christopher; Chapman, Heather F; Blair, Palenque; Nice, Helen; Reitsema, Tarren

    2014-03-01

    We investigated water quality at an advanced water reclamation plant and three conventional wastewater treatment plants using an "ecotoxicity toolbox" consisting of three complementary analyses (chemical analysis, in vitro bioanalysis and in situ biological monitoring), with a focus on endocrine disruption. The in vitro bioassays were chosen to provide an appropriately wide coverage of biological effects relevant to managed aquifer recharge and environmental discharge of treated wastewater, and included bioassays for bacterial toxicity (Microtox), genotoxicity (umuC), photosynthesis inhibition (Max-I-PAM) and endocrine effects (E-SCREEN and AR-CALUX). Chemical analysis of hormones and pesticides using LCMSMS was performed in parallel to correlate standard analytical methods with the in vitro assessment. For two plants with surface water discharge into open drains, further field work was carried out to examine in situ effects using mosquitofish (Gambusia holbrooki) as a bioindicator species for possible endocrine effects. The results show considerable cytotoxicity, phytotoxicity, estrogenicity and androgenicity in raw sewage, all of which were significantly reduced by conventional wastewater treatment. No biological response was detected to RO water, suggesting that reverse osmosis is a significant barrier to biologically active compounds. Chemical analysis and in situ monitoring revealed trends consistent with the in vitro results: chemical analysis confirmed the removal trends observed by the bioanalytical tools, and in situ sampling did not reveal any evidence of endocrine disruption specifically due to discharge of treated wastewater (although other sources may be present). Biomarkers of exposure (in vitro) and effect (in vivo or in situ) are complementary and together provide information with a high level of ecological relevance. This study illustrates the utility of combining multiple lines of evidence in the assessment of water quality. Copyright

  4. Microbiological Quality Control of Probiotic Products

    OpenAIRE

    Astashkina, A.P.; Khudyakova, L.I.; Kolbysheva, Y.V.

    2014-01-01

    Microbiological quality control of probiotic products such as Imunele, Dannon, Pomogayka showed that they contain living cultures of the Lactobacillus Bifidobacterium genus in the amount of 107 CFU/ml, which corresponds to the number indicated on the label of products. It is identified that the survival rate of test-strains cultured with pasteurized products does not exceed 10%. The cell concentration of target-microorganisms was reduced by 20-45% after the interaction with living probiotic b...

  5. Mitochondrial quality control in cardiac diseases.

    Directory of Open Access Journals (Sweden)

    Juliane Campos

    2016-10-01

    Full Text Available Disruption of mitochondrial homeostasis is a hallmark of cardiac diseases. Therefore, maintenance of mitochondrial integrity through different surveillance mechanisms is critical for cardiomyocyte survival. In this review, we discuss the most recent findings on the central role of mitochondrial quality control processes including regulation of mitochondrial redox balance, aldehyde metabolism, proteostasis, dynamics and clearance in cardiac diseases, highlighting their potential as therapeutic targets.

  6. Quality control and the multicrystal counter

    International Nuclear Information System (INIS)

    Hart, G.C.; Davis, K.M.

    1983-01-01

    The reliability of multicrystal counters for use in counting large numbers of radioimmunoassay samples is studied. In particular, the dependencies of the outputs from the array of detectors, and hence their degree of matching, on the count rate and volume of the samples being counted are investigated. Quality control procedures are described to assist in the assurance of consistent performance of the counter in the clinical situation. (U.K.)

  7. The software quality control for gamma spectrometry

    International Nuclear Information System (INIS)

    Monte, L.

    1986-01-01

    One of major problems with wich the quality control program of an environmental measurements laboratory is confronted is the evaluation of the performances of software packages for the analysis of gamma-ray spectra. A program of tests for evaluating the performances of the software package (SPECTRAN-F, Canberra Inc.) used by our laboratory is being carried out. In this first paper the results of a preliminary study concerning the evaluation of the performance of the doublet analysis routine are presented

  8. Quality control of estrogen receptor assays.

    Science.gov (United States)

    Godolphin, W; Jacobson, B

    1980-01-01

    Four types of material have been used for the quality control of routine assays of estrogen receptors in human breast tumors. Pieces of hormone-dependent Nb rat mammary tumors gave a precision about 40%. Rat uteri and rat tumors pulverized at liquid nitrogen temperature and stored as powder yielded precision about 30%. Powdered and lyophilised human tumors appear the best with precision as good as 17%.

  9. Opportunities for Automated Demand Response in Wastewater Treatment Facilities in California - Southeast Water Pollution Control Plant Case Study

    Energy Technology Data Exchange (ETDEWEB)

    Olsen, Daniel [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Goli, Sasank [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Faulkner, David [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); McKane, Aimee [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2012-12-20

    This report details a study into the demand response potential of a large wastewater treatment facility in San Francisco. Previous research had identified wastewater treatment facilities as good candidates for demand response and automated demand response, and this study was conducted to investigate facility attributes that are conducive to demand response or which hinder its implementation. One years' worth of operational data were collected from the facility's control system, submetered process equipment, utility electricity demand records, and governmental weather stations. These data were analyzed to determine factors which affected facility power demand and demand response capabilities The average baseline demand at the Southeast facility was approximately 4 MW. During the rainy season (October-March) the facility treated 40% more wastewater than the dry season, but demand only increased by 4%. Submetering of the facility's lift pumps and centrifuges predicted load shifts capabilities of 154 kW and 86 kW, respectively, with large lift pump shifts in the rainy season. Analysis of demand data during maintenance events confirmed the magnitude of these possible load shifts, and indicated other areas of the facility with demand response potential. Load sheds were seen to be possible by shutting down a portion of the facility's aeration trains (average shed of 132 kW). Load shifts were seen to be possible by shifting operation of centrifuges, the gravity belt thickener, lift pumps, and external pump stations These load shifts were made possible by the storage capabilities of the facility and of the city's sewer system. Large load reductions (an average of 2,065 kW) were seen from operating the cogeneration unit, but normal practice is continuous operation, precluding its use for demand response. The study also identified potential demand response opportunities that warrant further study: modulating variable-demand aeration loads, shifting

  10. Wastewater treatment of chemical laboratory using electro assisted-phytoremediation (EAPR)

    Science.gov (United States)

    Putra, Rudy Syah; Trahadinata, Gilang Ahmad; Latif, Arif; Solehudin, Mochamad

    2017-03-01

    The EAPR process using water hyacinth (Eichornia crassipes) on the wastewater treatment of chemical laboratory had been evaluated. The purpose of the EAPR process was to decrease the BOD, COD and heavy metal concentration in the wastewater. The effectiveness of the process on the wastewater treatment was evaluated using COD, BOD, and heavy metal (Pb, Cu) concentration, respectively. The result showed that the EAPR process decrease the COD, BOD, Pb and Cu in the 4 h of EAPR process. Those concentrations were met the water quality standard of class IV according to government regulation No. 82/2001 regarding the water quality management and water pollution control of the Republic of Indonesia.

  11. COD fractions changes in the SBR-type reactor treating municipal wastewater with controlled percentage of dairy sewage

    Directory of Open Access Journals (Sweden)

    Struk-Sokołowska Joanna

    2017-01-01

    Full Text Available The aim of study was to investigate the influence of percentage of dairy wastewater in the municipal wastewater on the changes of COD fractions during the cycle of SBR-type reactor. The scope of the research included physicochemical analyses of municipal wastewater without dairy wastewater, dairy wastewater, mixture of municipal and dairy wastewater as well as treated sewage. Both the concentrations and the proportions between COD fractions changed in the SBR cycle. In raw municipal and dairy wastewater - XS, insoluble hardly bio-degradable fraction of COD dominated (49.6 and 64.5% respectively. In treated wastewater SI, COD for dissolved compounds that are not biologically decomposed (inert (from 62.1 to 74.6% dominated, while XS fraction was from 19.1 to 24.4%. The consumption rate of organic compounds depended on the type of COD fraction, SBR cycle phase and the percentage of dairy wastewater. The highest rates of organic compounds consumption were noted in the phase of mixing. In the case of fraction SI, no differences in concentration in the SBR cycle time, were found. Concentration of COD in treated wastewater was from 34.8 to 58.9 mgO2·L-1 (efficiency wastewater treatment from 96.0 to 98.6%.

  12. Statistical process control for radiotherapy quality assurance

    International Nuclear Information System (INIS)

    Pawlicki, Todd; Whitaker, Matthew; Boyer, Arthur L.

    2005-01-01

    Every quality assurance process uncovers random and systematic errors. These errors typically consist of many small random errors and a very few number of large errors that dominate the result. Quality assurance practices in radiotherapy do not adequately differentiate between these two sources of error. The ability to separate these types of errors would allow the dominant source(s) of error to be efficiently detected and addressed. In this work, statistical process control is applied to quality assurance in radiotherapy for the purpose of setting action thresholds that differentiate between random and systematic errors. The theoretical development and implementation of process behavior charts are described. We report on a pilot project is which these techniques are applied to daily output and flatness/symmetry quality assurance for a 10 MV photon beam in our department. This clinical case was followed over 52 days. As part of our investigation, we found that action thresholds set using process behavior charts were able to identify systematic changes in our daily quality assurance process. This is in contrast to action thresholds set using the standard deviation, which did not identify the same systematic changes in the process. The process behavior thresholds calculated from a subset of the data detected a 2% change in the process whereas with a standard deviation calculation, no change was detected. Medical physicists must make decisions on quality assurance data as it is acquired. Process behavior charts help decide when to take action and when to acquire more data before making a change in the process

  13. 7 CFR 58.642 - Quality control tests.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Quality control tests. 58.642 Section 58.642... Procedures § 58.642 Quality control tests. All mix ingredients shall be subject to inspection for quality and condition throughout each processing operation. Quality control tests shall be made on flow line samples as...

  14. 7 CFR 58.928 - Quality control tests.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Quality control tests. 58.928 Section 58.928... Procedures § 58.928 Quality control tests. All dairy products and other ingredients shall be subject to inspection for quality and condition throughout each processing operation. Quality control tests shall be...

  15. 7 CFR 58.335 - Quality control tests.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Quality control tests. 58.335 Section 58.335... Procedures § 58.335 Quality control tests. All milk, cream and related products are subject to inspection for quality and condition throughout each processing operation. Quality control tests shall be made on flow...

  16. Development of phantom periapical for control quality

    International Nuclear Information System (INIS)

    Mendes, J.M.S.; Sales Junior, E.S.; Ferreira, F.C.L.; Paschoal, C.M.M.

    2015-01-01

    This study aimed to develop a dental phantom with cysts for evaluation of periapical radiographs that was tested in private dental offices in the city of Maraba, northern Brazil. Through some tests with the object simulator (phantom) were obtained 12 periapical radiographs (one in each of the offices visited) that waking up to the standards of Ordinance No. 453 were visually evaluated by observing the physical parameters of exposure (kVp and mA), time revelation of the radiographic film, later the other radiographs were visually compared with C6 ray set as the default. Among the results, it was found that only two of the twelve rays cysts could not be viewed and, therefore, these two images were deemed unsuitable for accurate diagnosis in the 10 images the cysts could be displayed, however according the images have different qualities comparisons. In addition, it can be concluded that the performance of the phantom was highly satisfactory showing to be efficient for use in quality control testing of dental X-rays, the quality control of radiographs and continuing education of dental professionals for a price much more accessible. (authors)

  17. Quality Management of CERN Vacuum Controls

    CERN Document Server

    Antoniotti, F; Fortescue-Beck, E; Gama, J; Gomes, P; Le Roux, P; Pereira, H; Pigny, G

    2014-01-01

    The vacuum controls Section (TE-VSC-ICM) is in charge of the monitoring, maintenance and consolidation of the control systems of all accelerators and detectors in CERN; this represents 6 000 instruments distributed along 128 km of vacuum chambers, often of heterogeneous architectures and of diverse technical generations. In order to improve the efficiency of the services provided by ICM, to vacuum experts and to accelerator operators, a Quality Management Plan is being put into place. The first step was the standardization of the naming convention across different accelerators. The traceability of problems, requests, repairs, and other actions, has also been put into place (VTL). This was combined with the effort to identify each individual device by a coded label, and register it in a central database (MTF). Occurring in parallel, was the gathering of old documents and the centralization of information concerning architectures, procedures, equipment and settings (EDMS). To describe the topology of control c...

  18. Pollution loads in urban runoff and sanitary wastewater.

    Science.gov (United States)

    Taebi, Amir; Droste, Ronald L

    2004-07-05

    While more attention has been paid in recent years to urban point source pollution control through the establishment of wastewater treatment plants in many developing countries, no considerable planning nor any serious measures have been taken to control urban non-point source pollution (urban stormwater runoff). The present study is a screening analysis to investigate the pollution loads in urban runoff compared to point source loads as a first prerequisite for planning and management of receiving water quality. To compare pollutant loads from point and non-point urban sources, the pollutant load is expressed as the weight of pollutant per hectare area per year (kg/ha.year). Unit loads were estimated in stormwater runoff, raw sanitary wastewater and secondary treatment effluents in Isfahan, Iran. Results indicate that the annual pollution load in urban runoff is lower than the annual pollution load in sanitary wastewater in areas with low precipitation but it is higher in areas with high precipitation. Two options, namely, advanced treatment (in lieu of secondary treatment) of sanitary wastewater and urban runoff quality control systems (such as detention ponds) were investigated as controlling systems for pollution discharges into receiving waters. The results revealed that for Isfahan, as a low precipitation urban area, advanced treatment is a more suitable option, but for high precipitation urban areas, urban surface runoff quality control installations were more effective for suspended solids and oxygen-demanding matter controls, and that advanced treatment is the more effective option for nutrient control.

  19. Pollution loads in urban runoff and sanitary wastewater

    International Nuclear Information System (INIS)

    Taebi, Amir; Droste, Ronald L.

    2004-01-01

    While more attention has been paid in recent years to urban point source pollution control through the establishment of wastewater treatment plants in many developing countries, no considerable planning nor any serious measures have been taken to control urban non-point source pollution (urban stormwater runoff). The present study is a screening analysis to investigate the pollution loads in urban runoff compared to point source loads as a first prerequisite for planning and management of receiving water quality. To compare pollutant loads from point and non-point urban sources, the pollutant load is expressed as the weight of pollutant per hectare area per year (kg/ha·year). Unit loads were estimated in stormwater runoff, raw sanitary wastewater and secondary treatment effluents in Isfahan, Iran. Results indicate that the annual pollution load in urban runoff is lower than the annual pollution load in sanitary wastewater in areas with low precipitation but it is higher in areas with high precipitation. Two options, namely, advanced treatment (in lieu of secondary treatment) of sanitary wastewater and urban runoff quality control systems (such as detention ponds) were investigated as controlling systems for pollution discharges into receiving waters. The results revealed that for Isfahan, as a low precipitation urban area, advanced treatment is a more suitable option, but for high precipitation urban areas, urban surface runoff quality control installations were more effective for suspended solids and oxygen-demanding matter controls, and that advanced treatment is the more effective option for nutrient control

  20. Photocatalytic removal of perfluoroalkyl substances from water and wastewater: Mechanism, kinetics and controlling factors.

    Science.gov (United States)

    Xu, Bentuo; Ahmed, Mohammad Boshir; Zhou, John L; Altaee, Ali; Wu, Minghong; Xu, Gang

    2017-12-01

    This review focuses on heterogeneous photocatalysis of perfluoroalkyl substances (PFAS) which are of worldwide concern as emerging persistent organic contaminants. Heterogeneous photocatalysis is an effective and advanced technology for PFAS removal from water with relatively high efficacy. During photocatalysis, various short chain perfluorocarboxylic acids (PFCA) are produced as intermediates and the efficacy is related to the photo-generated hole (h + ) and photo-generated electron (e - ). PFAS photodegradation in water under UV irradiation is most effective by using In 2 O 3 as the catalyst, followed by Ga 2 O 3 and TiO 2 . Significantly, modifying the chemical composition or morphology of the catalyst can improve its efficacy for PFAS removal. In 2 O 3 porous nanoplates were found to have the best performance of 100% PFAS decomposition under UV light with rate constant (k t ) and half-time (τ 1/2 ) of 0.158 min -1 and 4.4 min, respectively. Catalysts perform well in acidic solution and increasing temperature to a certain extent. The photocatalytic performance is reduced when treating wastewater due to the presence of dissolved organic matter (DOM), with the catalysts following the order: needle-like Ga 2 O 3  > In 2 O 3  > TiO 2 . Future studies should focus on the development of novel photocatalysts, and their immobilization and application for PFAS removal in wastewater. Copyright © 2017 Elsevier Ltd. All rights reserved.

  1. Microbiological quality control practices at Australian Radioisotopes

    International Nuclear Information System (INIS)

    Saunders, M.

    1987-01-01

    As a domestic manufacturer of therapeutic substances, Australian Radioisotopes (ARI) must adhere to guidelines set out by the Commonwealth Department of Health in the Code of Good Manufacturing Practices for Therapeutic Goods 1983 (GMP). The GMP gives guidelines for staff training, building requirements, sanitation, documentation and quality control practices. These guidelines form the basis for regular audits performed by officers of the National Biological Standards Laboratories. At Lucas Heights, ARI has combined the principles of the GMP with the overriding precautions introduced for environmental and staff safety and protection. Its policy is to maintain a high level of quality assurance for product identity, purity and sterility and apyrogenicity during all stages of product manufacture

  2. Basic quality control in diagnostic radiology

    International Nuclear Information System (INIS)

    Wikstrom, Erik

    2016-01-01

    Along the route toward regular performance of Quality Control in the Diagnostic Imaging sector there are a number of balances to negotiate: Patient/Staff safety considerations vs Regulatory compliance vs Performance of modern equipment vs Clinic's Productivity. At first glance these ambitions may seem in conflict. The tests performed to meet regulatory requirements may or may not bear any semblance to real clinical measurement scenarios. And the process of collecting the data from the quality assurance tests may induce a system down- time that adversely affects the clinic's overall productivity. Furthermore, the time it takes to complete the analysis of the test data and provide the report required to take the facility back into operation is time wasted for patients waiting for a diagnostic imaging exam

  3. Control of occupational exposure to phenol in industrial wastewater treatment plant of a petroleum refinery in Alexandria, Egypt: An intervention application case study.

    Science.gov (United States)

    Zaki, Gehan R; El-Marakby, Fadia A; Ramadan, Alaa El-Din K; Issa, Ahmed I; Nofal, Faten H

    2016-11-01

    Phenol exposure is one of the hazards in the industrial wastewater treatment basin of any refinery. It additively interacts with hydrogen sulfide emitted from the wastewater basin. Consequently, its concentration should be greatly lower than its threshold limit value. The present study aimed at controlling occupational exposure to phenol in the work environment of wastewater treatment plant in a refinery by reducing phenolic compounds in the industrial wastewater basin. This study was conducted on both laboratory and refinery scales. The first was completed by dividing each wastewater sample from the outlets of different refinery units into three portions; the first was analyzed for phenolic compounds. The second and third were for laboratory scale charcoal and bacterial treatments. The two methods were compared regarding their simplicities, design, and removal efficiencies. Accordingly, bacterial treatment by continuous flow of sewage water containing Pseudomonas Aeruginosa was used for refinery scale treatment. Laboratory scale treatment of phenolic compounds revealed higher removal efficiency of charcoal [100.0(0.0) %] than of bacteria [99.9(0.013) %]. The refinery scale bacterial treatment was [99.8(0.013) %] efficient. Consequently, level of phenol in the work environment after refinery-scale treatment [0.069(0.802) mg/m(3)] was much lower than that before [5.700(26.050) mg/m(3)], with removal efficiency of [99.125(2.335) %]. From the present study, we can conclude that bacterial treatment of phenolic compounds in industrial wastewater of the wastewater treatment plant using continuous flow of sewage water containing Pseudomonas Aeruginosa reduces the workers' exposure to phenol.

  4. ANALYSIS OF QUALITY COSTS FOR STATISTICA QUALITY CONTROL PLANNING

    Directory of Open Access Journals (Sweden)

    N. Chiadamrong

    2017-12-01

    Full Text Available Quality has become one or the most important force leading to organizational success and company growth in national and international markets. The return-on-investment from strong and effective quality programs is providing excellent profitability results in firms with effective quality strategies. Due to the wide variation in quality results, the search for the genuine keys to success in quality has become a matter of deep concern to management of companies. This paper suggests a way to quantifying quality costs. As a result, the appropriate quality strategies can be adjusted and set to match with each company situation based on the categorization of the quality costs suggested. This outcome can, then, be used as a guideline for manufactures in setting their suitable quality program, which establishes the proper balance between the costs and customer services.

  5. 40 CFR 75.21 - Quality assurance and quality control requirements.

    Science.gov (United States)

    2010-07-01

    ... quality assurance audit or any other audit, the system is out-of-control. The owner or operator shall... 40 Protection of Environment 16 2010-07-01 2010-07-01 false Quality assurance and quality control... assurance and quality control requirements. (a) Continuous emission monitoring systems. The owner or...

  6. Distributed sensor architecture for intelligent control that supports quality of control and quality of service.

    Science.gov (United States)

    Poza-Lujan, Jose-Luis; Posadas-Yagüe, Juan-Luis; Simó-Ten, José-Enrique; Simarro, Raúl; Benet, Ginés

    2015-02-25

    This paper is part of a study of intelligent architectures for distributed control and communications systems. The study focuses on optimizing control systems by evaluating the performance of middleware through quality of service (QoS) parameters and the optimization of control using Quality of Control (QoC) parameters. The main aim of this work is to study, design, develop, and evaluate a distributed control architecture based on the Data-Distribution Service for Real-Time Systems (DDS) communication standard as proposed by the Object Management Group (OMG). As a result of the study, an architecture called Frame-Sensor-Adapter to Control (FSACtrl) has been developed. FSACtrl provides a model to implement an intelligent distributed Event-Based Control (EBC) system with support to measure QoS and QoC parameters. The novelty consists of using, simultaneously, the measured QoS and QoC parameters to make decisions about the control action with a new method called Event Based Quality Integral Cycle. To validate the architecture, the first five Braitenberg vehicles have been implemented using the FSACtrl architecture. The experimental outcomes, demonstrate the convenience of using jointly QoS and QoC parameters in distributed control systems.

  7. Distributed Sensor Architecture for Intelligent Control that Supports Quality of Control and Quality of Service

    Directory of Open Access Journals (Sweden)

    Jose-Luis Poza-Lujan

    2015-02-01

    Full Text Available This paper is part of a study of intelligent architectures for distributed control and communications systems. The study focuses on optimizing control systems by evaluating the performance of middleware through quality of service (QoS parameters and the optimization of control using Quality of Control (QoC parameters. The main aim of this work is to study, design, develop, and evaluate a distributed control architecture based on the Data-Distribution Service for Real-Time Systems (DDS communication standard as proposed by the Object Management Group (OMG. As a result of the study, an architecture called Frame-Sensor-Adapter to Control (FSACtrl has been developed. FSACtrl provides a model to implement an intelligent distributed Event-Based Control (EBC system with support to measure QoS and QoC parameters. The novelty consists of using, simultaneously, the measured QoS and QoC parameters to make decisions about the control action with a new method called Event Based Quality Integral Cycle. To validate the architecture, the first five Braitenberg vehicles have been implemented using the FSACtrl architecture. The experimental outcomes, demonstrate the convenience of using jointly QoS and QoC parameters in distributed control systems.

  8. Quality control in quantitative computed tomography

    International Nuclear Information System (INIS)

    Jessen, K.A.; Joergensen, J.

    1989-01-01

    Computed tomography (CT) has for several years been an indispensable tool in diagnostic radiology, but it is only recently that extraction of quantitative information from CT images has been of practical clinical value. Only careful control of the scan parameters, and especially the scan geometry, allows useful information to be obtained; and it can be demonstrated by simple phantom measurements how sensitive a CT system can be to variations in size, shape and position of the phantom in the gantry aperture. Significant differences exist between systems that are not manifested in normal control of image quality and general performance tests. Therefore an actual system has to be analysed for its suitability for quantitative use of the images before critical clinical applications are justified. (author)

  9. Quality control concept for radioactive waste packages

    International Nuclear Information System (INIS)

    Warnecke, E.; Martens, B.R.; Odoj, R.

    1990-01-01

    In the Federal Republic of Germany a contract with the BfS for the performance of quality control measures is necessary. It is principally possible to apply two alternative methods: random checks on waste packages or qualification of conditioning processes with subsequent inspections. Priority is given to the control by the process qualification. Both methods have successfully been developed in the Federal Republic of Germany and can be applied. In the course of the qualification of conditioning processes it must be demonstrated by inactive and/or active runs that waste packages are produced which fulfil the waste acceptance requirements. The qualification results in the fixation of a handbook for the operation of the respective conditioning process including the process instrumentation and the operational margins. The qualified process will be inspected to assure the compliance of the actual operation with the conditions fixed in the handbook. (orig./DG)

  10. Software Quality Control at Belle II

    Science.gov (United States)

    Ritter, M.; Kuhr, T.; Hauth, T.; Gebard, T.; Kristof, M.; Pulvermacher, C.; Belle Software Group, II

    2017-10-01

    Over the last seven years the software stack of the next generation B factory experiment Belle II has grown to over one million lines of C++ and Python code, counting only the part included in offline software releases. There are several thousand commits to the central repository by about 100 individual developers per year. To keep a coherent software stack of high quality that it can be sustained and used efficiently for data acquisition, simulation, reconstruction, and analysis over the lifetime of the Belle II experiment is a challenge. A set of tools is employed to monitor the quality of the software and provide fast feedback to the developers. They are integrated in a machinery that is controlled by a buildbot master and automates the quality checks. The tools include different compilers, cppcheck, the clang static analyzer, valgrind memcheck, doxygen, a geometry overlap checker, a check for missing or extra library links, unit tests, steering file level tests, a sophisticated high-level validation suite, and an issue tracker. The technological development infrastructure is complemented by organizational means to coordinate the development.

  11. Simulation of Constructed Wetland in treating Wastewater using Fuzzy Logic Technique

    Science.gov (United States)

    Sudarsan, J. S.; Subramani, Sheekha; Rajan, Rajitha J.; Shah, Isha; Nithiyanantham, S.

    2018-04-01

    Constructed wetlands act as a natural alternative to conventional methods of wastewater treatment. CW are found effective in wastewater containing inorganic matter, organic matter, toxic compounds, metals, nitrogen, phosphorous, heavy metals, organic chemicals, and pathogens. The treatment efficiency by the adaptation of CWs in treatment process is achieved by a complex interaction between plants, microorganisms, soil matrix and substances in the wastewater. Constructed wetland treatment systems are engineered systems designed in such a manner that it could take advantages of those processes occurring in natural wetlands in treating the wastewater concerned, but in a more controlled environment. Petrochemical wastewater was the type of wastewater taken for the study. Characteristics of petrochemical wastewater mainly oil, Biological Oxygen Demand (BOD) and Chemical oxygen demand (COD) were selected for treatment in constructed wetland as they are predominant in petrochemical wastewater. The conventional methods followed in the treatment are chemical and biological treatment. In this study, a fuzzy model for water quality assessment has been developed and water quality index value was obtained. The experiment conducted and further analysis using fuzzy logic indicated that interpretation of certain imprecise data can be improved within fuzzy inference system (FIS). Based on the analysis, we could observe that Typha sp contained wetland cell showed greater efficiency in removal of parameters such as COD and BOD than Phragmites sp. wetland cell.

  12. Quality control of nuclear medicine instruments

    International Nuclear Information System (INIS)

    1984-11-01

    This document, which gives detailed guidance on the quality control of the various electronic instruments used for radiation detection and measurement in nuclear medicine, stems from the work of two Advisory Groups convened by the International Atomic Energy Agency (IAEA). A preliminary document, including recommended test schedules but lacking actual protocols for the tests, was drawn up by the first of these groups, meeting at the IAEA Headquarters in Vienna in 1979. A revised and extended version, incorporating recommended test protocols, was prepared by the second Group, meeting likewise in Vienna in 1982. This version is the model for the present text. The document should be of value to all nuclear medicine units, and especially to those in developing countries, in the initiation or revision of schemes for the quality control of their instruments. Its recommendations have provided the basis for instruction in two IAEA regional technical co-operation projects in the subject field, one initiated in 1981 for countries of Latin America and one initiated in 1982 for countries of Asia and the Pacific

  13. Toward standardising gamma camera quality control procedures

    International Nuclear Information System (INIS)

    Alkhorayef, M.A.; Alnaaimi, M.A.; Alduaij, M.A.; Mohamed, M.O.; Ibahim, S.Y.; Alkandari, F.A.; Bradley, D.A.

    2015-01-01

    Attaining high standards of efficiency and reliability in the practice of nuclear medicine requires appropriate quality control (QC) programs. For instance, the regular evaluation and comparison of extrinsic and intrinsic flood-field uniformity enables the quick correction of many gamma camera problems. Whereas QC tests for uniformity are usually performed by exposing the gamma camera crystal to a uniform flux of gamma radiation from a source of known activity, such protocols can vary significantly. Thus, there is a need for optimization and standardization, in part to allow direct comparison between gamma cameras from different vendors. In the present study, intrinsic uniformity was examined as a function of source distance, source activity, source volume and number of counts. The extrinsic uniformity and spatial resolution were also examined. Proper standard QC procedures need to be implemented because of the continual development of nuclear medicine imaging technology and the rapid expansion and increasing complexity of hybrid imaging system data. The present work seeks to promote a set of standard testing procedures to contribute to the delivery of safe and effective nuclear medicine services. - Highlights: • Optimal parameters for quality control of the gamma camera are proposed. • For extrinsic and intrinsic uniformity a minimum of 15,000 counts is recommended. • For intrinsic flood uniformity the activity should not exceed 100 µCi (3.7 MBq). • For intrinsic uniformity the source to detector distance should be at least 60 cm. • The bar phantom measurement must be performed with at least 15 million counts.

  14. Performance and quality control of scintillation cameras

    International Nuclear Information System (INIS)

    Moretti, J.L.; Iachetti, D.

    1983-01-01

    Acceptance testing, quality and control assurance of gamma-cameras are a part of diagnostic quality in clinical practice. Several parameters are required to achieve a good diagnostic reliability: intrinsic spatial resolution, spatial linearity, uniformities, energy resolution, count-rate characteristics, multiple window spatial analysis. Each parameter was measured and also estimated by a test easy to implement in routine practice. Material required was a 4028 multichannel analyzer linked to a microcomputeur, mini-computers and a set of phantoms (parallel slits, diffusing phantom, orthogonal hole transmission pattern). Gamma-cameras on study were:CGR 3400, CGR 3420, G.E.4000. Siemens ZLC 75 and large field Philips. Several tests proposed by N.E.M.A. and W.H.O. have to be improved concerning too punctual spatial determinations during distortion measurements with multiple window. Contrast control of image need to be monitored with high counting rate. This study shows the need to avoid punctual determinations and the interest to give sets of values of the same parameter on the whole field and to report mean values with their standard variation [fr

  15. Spray drying of a phenolic-rich membrane filtration fraction of olive mill wastewater: Optimization and dried product quality

    Science.gov (United States)

    Olive mill wastewater (OMWW) from two California mills (3-phase and 2-phase) was subjected to a two-step membrane filtration process using a novel vibratory system. The obtained reverse osmosis retentate (RO-R) is a phenolic-rich co-product stream, and the reverse osmosis permeate is a near-pure wat...

  16. Effect of purified wastewater from the city of Settat (Morocco on the quality of Lippia citriodora essential oil and infusion

    Directory of Open Access Journals (Sweden)

    Fatima Bensabah

    2015-06-01

    The infusion of L. citriodora prepared by the fresh and dried leaves irrigated with wastewater contains a high concentration of NH4+, Ca2+, Mg2+, and the concentration of NO2–N (mg/L exceeds 100% of the concentration of waste water.

  17. Irrigation of an established vineyard with winery cleaning agent solution (simulated winery wastewater): vine growth, berry quality, and soil chemistry

    Science.gov (United States)

    The ability to use winery wastewater (WW) for irrigation purposes could be a beneficial to the wine industry. A major difficulty in studying WW use is its inconsistent availability and composition. As such, we applied four simulated WWs composed of salts from two main industrial cleaning agents, and...

  18. Quality control of radioiodinated gastrin for radioimmunoassay

    International Nuclear Information System (INIS)

    Ginabreda, M.G.P.; Borghi, V.C.; Bettarello, A.

    1988-07-01

    Radioiodinated human gastrin has been prepared at IPEN laboratory for radioimmunoassay use. This work developed the quality control of this tracer analyzing parameters of the labelling reaction, chromatographic purification and radioimmunoassay. The radioiodination yield obtained in five experiments was reproducible and similar when analyzed on 7% polyaraylamide gel eletrophoresis - PAGE - (mean + - SD of 51.70 + - 10.76%) and by1 25 I incorporation checked through thrichloroacetic acid precipitation - TCA - (57-36 + - 9.69%). Similary, after purification the labelled gastrin revaled high and reproducible purity degree when submitted to PAGE (96.57 + - 1.06%) and CA (94.82 + - 4.20%) analysis. The respective specific activities varied from 62 to 307 uCi/ug, being determined by the self-displacement method, which is based on the immunoactivity of the tracer. In this way, the antibody titers required to bind 50% of the tracer ranged from 1:32.000 to 1:180.000. Consequently, the respective doses producing 50% fall in the maximum response of the radioimmunoassays ranged from 155.0 to 24.0 pmol/1, but remained unchanged for each tracer even after three months of its preparations. The tracers presented very low non-specific binding values (1.78 + - 0.79%), stablespecific binding values (46.49 + - 5.65%) and a good between-assay precision, evaluated by an internal quality control sample (25.71 + - 4.30%) with coefficient of variation of 16.74%). The PAGE analysis of the unlabeled gastrin used in the first and last radioiodination revealed an unique and unaltered component, confirming the quality of the tracers. (author) [pt

  19. 7 CFR 58.141 - Alternate quality control program.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Alternate quality control program. 58.141 Section 58... Service 1 Quality Specifications for Raw Milk § 58.141 Alternate quality control program. When a plant has in operation an acceptable quality program, at the producer level, which is approved by the...

  20. Technology requirement for Halal quality control | Husny | Journal of ...

    African Journals Online (AJOL)

    Technology requirement for Halal quality control. ... Findings show that each industry segments have different technology characteristics preference. ... Keywords: halal industry, quality control; technology assistance; food and beverage; ...

  1. Calibration Transfer Between a Bench Scanning and a Submersible Diode Array Spectrophotometer for In Situ Wastewater Quality Monitoring in Sewer Systems.

    Science.gov (United States)

    Brito, Rita S; Pinheiro, Helena M; Ferreira, Filipa; Matos, José S; Pinheiro, Alexandre; Lourenço, Nídia D

    2016-03-01

    Online monitoring programs based on spectroscopy have a high application potential for the detection of hazardous wastewater discharges in sewer systems. Wastewater hydraulics poses a challenge for in situ spectroscopy, especially when the system includes storm water connections leading to rapid changes in water depth, velocity, and in the water quality matrix. Thus, there is a need to optimize and fix the location of in situ instruments, limiting their availability for calibration. In this context, the development of calibration models on bench spectrophotometers to estimate wastewater quality parameters from spectra acquired with in situ instruments could be very useful. However, spectra contain information not only from the samples, but also from the spectrophotometer generally invalidating this approach. The use of calibration transfer methods is a promising solution to this problem. In this study, calibration models were developed using interval partial least squares (iPLS), for the estimation of total suspended solids (TSS) and chemical oxygen demand (COD) in sewage from Ultraviolet-visible spectra acquired in a bench scanning spectrophotometer. The feasibility of calibration transfer to a submersible, diode array equipment, to be subsequently operated in situ, was assessed using three procedures: slope and bias correction (SBC); single wavelength standardization (SWS) on mean spectra; and local centering (LC). The results showed that SBC was the most adequate for the available data, adding insignificant error to the base model estimates. Single wavelength standardization was a close second best, potentially more robust, and independent of the base iPLS model. Local centering was shown to be inadequate for the samples and instruments used. © The Author(s) 2016.

  2. Managing Air Quality - Control Strategies to Achieve Air Pollution Reduction

    Science.gov (United States)

    Considerations in designing an effective control strategy related to air quality, controlling pollution sources, need for regional or national controls, steps to developing a control strategy, and additional EPA resources.

  3. 10 CFR 26.137 - Quality assurance and quality control.

    Science.gov (United States)

    2010-01-01

    ... cutoff concentration for the compound of interest, a control without the compound of interest (i.e., a certified negative control), and a control with at least one of the compounds of interest at a measurable... calibrator, a control without the compound of interest (i.e., a certified negative control), and a control...

  4. 14 CFR 21.147 - Changes in quality control system.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Changes in quality control system. 21.147 Section 21.147 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION... quality control system. After the issue of a production certificate, each change to the quality control...

  5. 14 CFR 145.211 - Quality control system.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Quality control system. 145.211 Section 145...) SCHOOLS AND OTHER CERTIFICATED AGENCIES REPAIR STATIONS Operating Rules § 145.211 Quality control system. (a) A certificated repair station must establish and maintain a quality control system acceptable to...

  6. 7 CFR 58.523 - Laboratory and quality control tests.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Laboratory and quality control tests. 58.523 Section... Service 1 Operations and Operating Procedures § 58.523 Laboratory and quality control tests. (a) Quality control tests shall be made on samples as often as necessary to determine the shelf-life and stability of...

  7. 18 CFR 12.40 - Quality control programs.

    Science.gov (United States)

    2010-04-01

    ... 18 Conservation of Power and Water Resources 1 2010-04-01 2010-04-01 false Quality control... PROJECT WORKS Other Responsibilities of Applicant or Licensee § 12.40 Quality control programs. (a... meeting any requirements or standards set by the Regional Engineer. If a quality control program is...

  8. 21 CFR 640.56 - Quality control test for potency.

    Science.gov (United States)

    2010-04-01

    ... quality control test for potency may be performed by a clinical laboratory which meets the standards of... 21 Food and Drugs 7 2010-04-01 2010-04-01 false Quality control test for potency. 640.56 Section...) BIOLOGICS ADDITIONAL STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Cryoprecipitate § 640.56 Quality control...

  9. Seasonal effects of wastewater to the water quality of the Caeté river estuary, Brazilian Amazon

    Directory of Open Access Journals (Sweden)

    Luci C.C. Pereira

    2010-06-01

    Full Text Available Bragança's socioeconomic situation is highly dependent on estuarine and marine biological resources that are influenced by tidal cycles and climatology. Field measurements (hydrological, hydrodynamic and microbiological variables were taken in the most urbanized zone from Caeté estuary to characterise the quality of the local environment. During the dry period, the estuary was more eutrophic and presented the highest temperature (30.5 °C in Oct./06, salinity (17 psu in Feb./07, pH (8.24 in Feb./07 and fecal coliform (> 1000 MPN/100 ml in Dec./06 and Feb./07 values. The phytoplankton Cyclotella meneghiniana, Coscinodiscus centralis and other r-strategist species were observed. The lack of basic hydric canalization was responsible for the local contamination, especially during the dry period when more concentrated wastewater from the city was emitted into the estuary, showing the human influence on the reduction of local estuarine water quality. In Bragança, the fishery is considered one of the main economic activities so, this contamination is worrisome because a large part of the local economy depends on biological resources and, thus, the contamination could negatively affect the environmental health of this Amazon ecosystem.A situação socioeconômica de Bragança depende principalmente dos recursos biológicos estuarinos e marinhos, que são influenciados pelos ciclos de marés e climatologia. Coletas oceanográficas (com medidas de variáveis hidrológicas, hidro-dinâmicas e microbiológicas foram realizadas na área mais urbanizada do estuário do Caeté, para caracterizar a qualidade das águas no setor estudado. Durante o período seco, o estuário foi mais eutrófico e apresentou os maiores valores de temperatura (30,5°C em Out./06, salinidade (17 psu em Fev./07, pH (8,24 em Fev./07 e coliformes fecais (>1000 MNP/ 100 ml em Dez./06 e Fev./07. As espécies fitoplanctô-nicas Cyclotella meneghiniana, Coscinodiscus centralis e outras

  10. Quality control of ATLAS muon chambers

    CERN Document Server

    Fabich, Adrian

    ATLAS is a general-purpose experiment for the future Large Hadron Collider (LHC) at CERN. Its Muon Spectrometer will require ∼ 5500m2 of precision tracking chambers to measure the muon tracks along a spectrometer arm of 5m to 15m length, embedded in a magnetic field of ∼ 0.5T. The precision tracking devices in the Muon System will be high pressure drift tubes (MDTs). Approximately 370,000 MDTs will be assembled into ∼ 1200 drift chambers. The performance of the MDT chambers is very much dependent on the mechanical quality of the chambers. The uniformity and stability of the performance can only be assured providing very high quality control during production. Gas tightness, high-voltage behaviour and dark currents are global parameters which are common to gas detectors. For all chambers, they will be tested immediately after the chamber assembly at every production site. Functional tests, for example radioactive source scans and cosmic-ray runs, will be performed in order to establish detailed performan...

  11. Acceptance, commissioning and quality control in radiosurgery

    International Nuclear Information System (INIS)

    Toreti, Dalila Luzia

    2009-01-01

    Stereotactic Radiosurgery is a treatment technique that uses narrow beams of radiation focused with great accuracy in a small lesion. The introduction of micro multi leaf collimators (mMLC) allows this technique to reach a higher degree of dose conformation of the target lesion allowing a smaller irradiation of critical structures and normal tissues. This paper presents the results of the acceptance tests and commissioning of a Varian 6EX linear accelerator dedicated to radiosurgery associated with the BrainLab micro multi leaf collimator installed in the Hospital das Clinicas da Faculdade de Medicina da USP (HC-FMUSP) and establish feasible quality assurance program for the services that employ this special technique. The results of the acceptance tests were satisfactory and are willing with the specifications provided by the manufacturer and the commissioning tests were within the international recommendations. The tests and measures that are part of quality control process should be specific to each treatment unit, and the need, frequency and levels of tolerance

  12. Quality control in nuclear fuel fabrication

    International Nuclear Information System (INIS)

    Abdelhalim, A.S.; Elsayed, A.A.; Shaaban, H.I.

    1988-01-01

    The department of metallurgy, NRC Inchass is embarking on a programme of on a laboratory scale, fuel pins containing uranium dioxide pellets are going to be produced. The department is making use of the expertise and equipment at present available and is going to utilize the new fuel pin fabrication unit which would be shortly in operation. The fabrication and testing of uranium dioxide pellets then gradually adapt them and develop, a national know how in this field. This would also involve building up of indigenous experience through proper training of qualified personnel. That are applied to ensure quality of U o 2 pellets, the techniques implemented, the equipment used and the specifications of the equipment presently available. The following parameters are subject to quality control tests: density. O/U ration, hydrogen content, microstructure, each property will be discussed, measurements related to U o 2 powders, including flow ability, bulk density, O/U ratio, bet surface area and water content will be critically discussed. Relevant tests to ensure Q C of pellets are reviewed. These include surface integrity, density, dimensions, microstructure.4 fig., 1 tab

  13. Tools for quality control of fingerprint databases

    Science.gov (United States)

    Swann, B. Scott; Libert, John M.; Lepley, Margaret A.

    2010-04-01

    Integrity of fingerprint data is essential to biometric and forensic applications. Accordingly, the FBI's Criminal Justice Information Services (CJIS) Division has sponsored development of software tools to facilitate quality control functions relative to maintaining its fingerprint data assets inherent to the Integrated Automated Fingerprint Identification System (IAFIS) and Next Generation Identification (NGI). This paper provides an introduction of two such tools. The first FBI-sponsored tool was developed by the National Institute of Standards and Technology (NIST) and examines and detects the spectral signature of the ridge-flow structure characteristic of friction ridge skin. The Spectral Image Validation/Verification (SIVV) utility differentiates fingerprints from non-fingerprints, including blank frames or segmentation failures erroneously included in data; provides a "first look" at image quality; and can identify anomalies in sample rates of scanned images. The SIVV utility might detect errors in individual 10-print fingerprints inaccurately segmented from the flat, multi-finger image acquired by one of the automated collection systems increasing in availability and usage. In such cases, the lost fingerprint can be recovered by re-segmentation from the now compressed multi-finger image record. The second FBI-sponsored tool, CropCoeff was developed by MITRE and thoroughly tested via NIST. CropCoeff enables cropping of the replacement single print directly from the compressed data file, thus avoiding decompression and recompression of images that might degrade fingerprint features necessary for matching.

  14. Quality control tests for conventional mammography

    International Nuclear Information System (INIS)

    Dawod, Alnazer Ahmed Ibrahim

    2014-12-01

    Mammography is this the test that allows the radiologist to look at images of the inside of the breasts. Mammograms help detect breast cancer early successful treatment of breast cancer depends on that early diagnosis. Breast cancer is a very common condition. About one in every nine women develops breast cancer by the age of eighty. In addition to the clinical examination and self-examination, mammography plays important role in the detection of breast cancer before they become clinically visible tumors. The mammography is the most common test for early detection of breast cancer. Quality control techniques that done ensured importance of this programme to produce images with good diagnostic values and help radiologist to diagnose breast discase easily and avoid exposing patient to radiation hazards.(Author)

  15. Analytical quality control [An IAEA service

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1973-07-01

    In analytical chemistry the determination of small or trace amounts of elements or compounds in different types of materials is increasingly important. The results of these findings have a great influence on different fields of science, and on human life. Their reliability, precision and accuracy must, therefore, be checked by analytical quality control measures. The International Atomic Energy Agency (IAEA) set up an Analytical Quality Control Service (AQCS) in 1962 to assist laboratories in Member States in the assessment of their reliability in radionuclide analysis, and in other branches of applied analysis in which radionuclides may be used as analytical implements. For practical reasons, most analytical laboratories are not in a position to check accuracy internally, as frequently resources are available for only one method; standardized sample material, particularly in the case of trace analysis, is not available and can be prepared by the institutes themselves only in exceptional cases; intercomparisons are organized rather seldom and many important types of analysis are so far not covered. AQCS assistance is provided by the shipment to laboratories of standard reference materials containing known quantities of different trace elements or radionuclides, as well as by the organization of analytical intercomparisons in which the participating laboratories are provided with aliquots of homogenized material of unknown composition for analysis. In the latter case the laboratories report their data to the Agency's laboratory, which calculates averages and distributions of results and advises each laboratory of its performance relative to all the others. Throughout the years several dozens of intercomparisons have been organized and many thousands of samples provided. The service offered, as a consequence, has grown enormously. The programme for 1973 and 1974, which is currently being distributed to Member States, will contain 31 different types of materials.

  16. The growing need for analytical quality control

    International Nuclear Information System (INIS)

    Suschny, O.; Richman, D.M.

    1974-01-01

    Technological development in a country is directly dependent upon its analytical chemistry or measurement capability, because it is impossible to achieve any level of technological sophistication without the ability to measure. Measurement capability is needed to determine both technological competence and technological consequence. But measurement itself is insufficient. There must be a standard or a reference for comparison. In the complicated world of chemistry the need for reference materials grows with successful technological development. The International Atomic Energy Agency has been distributing calibrated radioisotope solutions, standard reference materials and intercomparison materials since the early 1960's. The purpose of this activity has been to help laboratories in its Member States to assess and, if necessary, to improve the reliability of their analytical work. The value and continued need of this service has been demonstrated by the results of many intercomparisons which proved that without continuing analytical quality control activities, adequate reliability of analytical data could not be taken for granted. Analytical chemistry, lacking the glamour of other aspects of the physical sciences, has not attracted the attention it deserves, but in terms of practical importance, it warrants high priority in any developing technological scheme, because without it there is little chance to evaluate technological success or failure or opportunity to identify the reasons for success or failure. The scope and the size of the future programme of the IAEA in this field has been delineated by recommendations made by several Panels of Experts; all have agreed on the importance of this programme and made detailed recommendations in their areas of expertise. The Agency's resources are limited and it cannot on its own undertake the preparation and distribution of all the materials needed. It can, however, offer a focal point to bring together different

  17. Terms and definitions of quality assurance/quality control

    International Nuclear Information System (INIS)

    Kaden, W.

    1980-01-01

    Terms of quality assurance are defined and interpreted. Reference is made to the IAEA Code of Practice and to other important Codes and Standards like ANSI, ASME and KTA. The relevance of these terms to everyday's work and problems of a quality assurance engineer is explained. (orig.)

  18. [Compatibility of different quality control systems].

    Science.gov (United States)

    Invernizzi, Enrico

    2002-01-01

    Management of the good laboratory practice (GLP) quality system presupposes its linking to a basic recognized and approved quality system, from which it can draw on management procedures common to all quality systems, such as the ISO 9000 set of norms. A quality system organized in this way can also be integrated with other dedicated quality systems, or parts of them, to obtain principles or management procedures for specific topics. The aim of this organization is to set up a reliable, recognized quality system compatible with the principles of GLP and other quality management systems, which provides users with a simplified set of easily accessible management tools and answers. The organization of this quality system is set out in the quality assurance programme, which is actually the document in which the test facility incorporates the GLP principles into its own quality organization.

  19. Regulation of wastewater treatment plants in the Ba-Phalaborwa municipality / Q.N. Gopo

    OpenAIRE

    Gopo, Nothando Lilian Queen

    2013-01-01

    South Africa is a water-scarce country and over the years, the quality of water resources has deteriorated due to poor effluent discharge, agricultural, industrial, mining and human activities. The major contributing factors of poorly-treated or inadequately treated wastewater may be attributed to: (a) the poor design and construction of wastewater treatment plants; (b) lack of qualified process controllers; (c) non-compliance with applicable legislation; (d) lack of proper monitoring; and (e...

  20. The use of Moringa Oleifera Seed Powder as Coagulant to Improve the Quality of Wastewater and Ground Water

    Science.gov (United States)

    Hendrawati; Rani Yuliastri, Indra; Nurhasni; Rohaeti, Eti; Effendi, Hefni; Darusman, Latifah K.

    2016-01-01

    Wastewater and ground water treatment are mostly using Polyaluminum Chloride (PAC), a synthetic coagulant, which possess health risk and require expensive cost. This research was carried out to observe the effect of Moringa oleifera seed as natural coagulant to replace synthetic coagulant. M. oleifera reduced 98.6% turbidity of wastewater, 10.8% of its conductivity, 11.7% of its BOD and removed its metal contents (Cd, Cr, Mn). When applied to ground water, M. oleifera removed the turbidity of ground water as much as 97.5%, while reduced the conductivity and BOD of ground water 53.4% and 18%, respectively. The use of M. oleifera also reduced total number of coliform. The advantage of using M. oleifera is that it does not reduce pH as PAC, hence does not require further treatment to adjust pH of the treated water.

  1. Advanced wastewater treatment system (SEADS)

    International Nuclear Information System (INIS)

    Dunn, J.

    2002-01-01

    'Full text:' This presentation will describe the nature, scope, and findings of a third-party evaluation of a wastewater treatment technology identified as the Advanced Wastewater Treatment System Inc.'s Superior Extended Aerobic Digester System (SEADS). SEADS is an advanced miniaturized wastewater treatment plant that can meet advanced wastewater treatment standards for effluent public reuse. SEADS goes beyond primary and secondary treatment operations to reduce nutrients such as nitrogen and phosphorus, which are typically found in excessive quantities in traditional wastewater treatment effluent. The objective of this evaluation will be to verify the performance and reliability of the SEADS to treat wastewater from a variety of sources, including domestic wastewater and commercial industrial wastewater. SEADS utilizes remote telemetry equipment to achieve added reliability and reduces monitoring costs as compared to many package wastewater treatment plants. The evaluation process will be overseen and coordinated by the Environmental Technology Evaluation Center (EvTEC), a program of the Civil Engineering Research Foundation (CERF), the research and technology transfer arm of the American Society of Civil Engineers (ASCE). EvTEC is a pilot program evaluating innovative environmental technologies under the US Environmental Protection Agency's (USEPA) Environmental Technology Verification (ETV) Program. Among other performance issues, the SEADS technology evaluation will address its ability to treat low flows-from remote individual and clustered housing applications, and individual commercial applications in lieu of a main station conventional wastewater treatment plant. The unneeded reliance on particular soil types for percolation and the improved effluent water quality over septic systems alone look to make these types of package treatment plants a viable option for rural communities, small farms, and other low-flow remote settings. Added benefits to be examined

  2. Requirements for quality control of analytical data

    International Nuclear Information System (INIS)

    Westmoreland, R.D.; Bartling, M.H.

    1990-07-01

    The National Contingency Plan (NCP) of the Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA) provides procedures for the identification, evaluation, and remediation of past hazardous waste disposal sites. The Hazardous Materials Response section of the NCP consists of several phases: Preliminary Assessment, Site Inspection, Remedial Investigation, Feasibility Study, Remedial Design, and Remedial Action. During any of these phases, analysis of soil, water, and waste samples may be performed. The Hazardous Waste Remedial Actions Program (HAZWRAP) is involved in performing field investigations and sample analyses pursuant to the NCP for the US Department of Energy and other federal agencies. The purpose of this document is to specify the requirements of Martin Marietta Energy Systems, Inc., for the control of accuracy, precision, and completeness of samples and data from the point of collection through analysis. Requirements include data reduction and reporting of resulting environmentally related data. Because every instance and concern may not be addressed in this document, HAZWRAP subcontractors are encouraged to discuss any questions with the Analytical Quality Control Specialist (AQCS) and the HAZWRAP Project Manager. This revision supercedes all other versions of this document

  3. Wastewater Districts

    Data.gov (United States)

    Vermont Center for Geographic Information — The Wastewater districts layer is part of a larger dataset that contains administrative boundaries for Vermont's Agency of Natural Resources. The dataset includes...

  4. Wastewater reuse

    OpenAIRE

    Milan R. Radosavljević; Vanja M. Šušteršič

    2013-01-01

    Water scarcity and water pollution are some of the crucial issues that must be addressed within local and global perspectives. One of the ways to reduce the impact of water scarcity  and to minimizine water pollution is to expand water and wastewater reuse. The local conditions including regulations, institutions, financial mechanisms, availability of local technology and stakeholder participation have a great influence on the decisions for wastewater reuse. The increasing awareness of food s...

  5. Combined impact of quorum quenching and backwashing on biofouling control in a semi-pilot scale mbr treating real wastewater

    International Nuclear Information System (INIS)

    Hasnain, G.; Khan, S.J.; Arshad, M.Z.; Abdullah, H.Y.

    2017-01-01

    This study demonstrates the combined effect of quorum quenching (QQ) and backwashing on biofouling control in MBR treating real wastewater. The quorum quenching mechanism is an emerging biological technique using Rhodococcus sp. entrapped in polymer coated sodium alginate beads whereas, backwashing is a distinguished physical technique for biofouling control. Two parallel semi-pilot scale MBRs i.e., QQ-MBR (quorum quenching MBR) with cell-entrapping beads (CEBs) and C-MBR (conventional MBR) with vacant CEBs at 0.5% effective volume of the bioreactor, were monitored for comparative performance evaluation. In the first phase, both the MBRs were operated without backwashing having operational cycle of eight min filtration and two min relaxation and in the second phase; MBRs were operated with backwashing having operation cycle of eight min filtration, one min relaxation and one min backwashing. QQ-MBR-with backwashing exhibited greater biofouling control capability and elongated filtration duration with respect to QQ-MBR without backwashing. Comparatively less soluble EPS concentrations were detected in QQ-MBR as compare to C-MBR in both modes of operation while backwashing contributed to retard the rapid increase in trans-membrane pressure (TMP) also known as TMP jump. Study reveals the novelty of successful application of combined influence of permeate backflushing technique and QQ (anti-biofouling) strategy in MBR and potential use for full scale applications. (author)

  6. Chapter 5: Quality assurance/quality control in stormwater sampling

    Science.gov (United States)

    Sampling the quality of stormwater presents unique challenges because stormwater flow is relatively short-lived with drastic variability. Furthermore, storm events often occur with little advance warning, outside conventional work hours, and under adverse weather conditions. Therefore, most stormwat...

  7. 21 CFR 111.117 - What quality control operations are required for equipment, instruments, and controls?

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 2 2010-04-01 2010-04-01 false What quality control operations are required for equipment, instruments, and controls? 111.117 Section 111.117 Food and Drugs FOOD AND DRUG ADMINISTRATION... and Process Control System: Requirements for Quality Control § 111.117 What quality control operations...

  8. Groundwater quality impacts from the land application of treated municipal wastewater in a large karstic spring basin: Chemical and microbiological indicators

    International Nuclear Information System (INIS)

    Katz, Brian G.; Griffin, Dale W.; Davis, J. Hal

    2009-01-01

    Geochemical and microbiological techniques were used to assess water-quality impacts from the land application of treated municipal wastewater in the karstic Wakulla Springs basin in northern Florida. Nitrate-N concentrations have increased from about 0.2 to as high as 1.1 mg/L (milligrams per liter) during the past 30 years in Wakulla Springs, a regional discharge point for groundwater (mean flow about 11.3 m 3 /s) from the Upper Floridan aquifer (UFA). A major source of nitrate to the UFA is the approximately 64 million L/d (liters per day) of treated municipal wastewater applied at a 774 ha (hectare) sprayfield farming operation. About 260 chemical and microbiological indicators were analyzed in water samples from the sprayfield effluent reservoir, wells upgradient from the sprayfield, and from 21 downgradient wells and springs to assess the movement of contaminants into the UFA. Concentrations of nitrate-N, boron, chloride, were elevated in water samples from the sprayfield effluent reservoir and in monitoring wells at the sprayfield boundary. Mixing of sprayfield effluent water was indicated by a systematic decrease in concentrations of these constituents with distance downgradient from the sprayfield, with about a 10-fold dilution at Wakulla Springs, about 15 km (kilometers) downgradient from the sprayfield. Groundwater with elevated chloride and boron concentrations in wells downgradient from the sprayfield and in Wakulla Springs had similar nitrate isotopic signatures, whereas the nitrate isotopic composition of water from other sites was consistent with inorganic fertilizers or denitrification. The sprayfield operation was highly effective in removing most studied organic wastewater and pharmaceutical compounds and microbial indicators. Carbamazepine (an anti-convulsant drug) was the only pharmaceutical compound detected in groundwater from two sprayfield monitoring wells (1-2 ppt). One other detection of carbamazepine was found in a distant well water

  9. Using chemical and microbiological indicators to track the impacts from the land application of treated municipal wastewater and other sources on groundwater quality in a karstic springs basin

    Science.gov (United States)

    Katz, Brian G.; Griffin, Dale W.

    2008-08-01

    Multiple chemical constituents (nutrients; N, O, H, C stable isotopes; 64 organic wastewater compounds, 16 pharmaceutical compounds) and microbiological indicators were used to assess the impact on groundwater quality from the land application of approximately 9.5 million liters per day of treated municipal sewage effluent to a sprayfield in the 960-km2 Ichetucknee Springs basin, northern Florida. Enriched stable isotope signatures (δ18O and δ2H) were found in water from the effluent reservoir and a sprayfield monitoring well (MW-7) due to evaporation; however, groundwater samples downgradient from the sprayfield have δ18O and δ2H concentrations that represented recharge of meteoric water. Boron and chloride concentrations also were elevated in water from the sprayfield effluent reservoir and MW-7, but concentrations in groundwater decreased substantially with distance downgradient to background levels in the springs (about 12 km) and indicated at least a tenfold dilution factor. Nitrate-nitrogen isotope (δ15N NO3) values above 10 ‰ in most water samples were indicative of organic nitrogen sources except Blue Hole Spring (δ15N NO3 = 4.6 4.9 ‰), which indicated an inorganic source of nitrogen (fertilizers). The detection of low concentrations the insect repellent N, N-diethyl-metatoluamide (DEET), and other organic compounds associated with domestic wastewater in Devil’s Eye Spring indicated that leakage from a nearby septic tank drainfield likely has occurred. Elevated levels of fecal coliforms and enterococci were found in Blue Hole Spring during higher flow conditions, which likely resulted from hydraulic connections to upgradient sinkholes and are consistent with previoius dye-trace studies. Enteroviruses were not detected in the sprayfield effluent reservoir, but were found in low concentrations in water samples from a downgradient well and Blue Hole Spring during high-flow conditions indicating a human wastewater source. The Upper Floridan aquifer

  10. Groundwater quality impacts from the land application of treated municipal wastewater in a large karstic spring basin: Chemical and microbiological indicators

    Energy Technology Data Exchange (ETDEWEB)

    Katz, Brian G. [U.S. Geological Survey, 2010 Levy Avenue, Tallahassee, Florida 32310 (United States)], E-mail: bkatz@usgs.gov; Griffin, Dale W.; Davis, J. Hal [U.S. Geological Survey, 2010 Levy Avenue, Tallahassee, Florida 32310 (United States)

    2009-04-01

    Geochemical and microbiological techniques were used to assess water-quality impacts from the land application of treated municipal wastewater in the karstic Wakulla Springs basin in northern Florida. Nitrate-N concentrations have increased from about 0.2 to as high as 1.1 mg/L (milligrams per liter) during the past 30 years in Wakulla Springs, a regional discharge point for groundwater (mean flow about 11.3 m{sup 3}/s) from the Upper Floridan aquifer (UFA). A major source of nitrate to the UFA is the approximately 64 million L/d (liters per day) of treated municipal wastewater applied at a 774 ha (hectare) sprayfield farming operation. About 260 chemical and microbiological indicators were analyzed in water samples from the sprayfield effluent reservoir, wells upgradient from the sprayfield, and from 21 downgradient wells and springs to assess the movement of contaminants into the UFA. Concentrations of nitrate-N, boron, chloride, were elevated in water samples from the sprayfield effluent reservoir and in monitoring wells at the sprayfield boundary. Mixing of sprayfield effluent water was indicated by a systematic decrease in concentrations of these constituents with distance downgradient from the sprayfield, with about a 10-fold dilution at Wakulla Springs, about 15 km (kilometers) downgradient from the sprayfield. Groundwater with elevated chloride and boron concentrations in wells downgradient from the sprayfield and in Wakulla Springs had similar nitrate isotopic signatures, whereas the nitrate isotopic composition of water from other sites was consistent with inorganic fertilizers or denitrification. The sprayfield operation was highly effective in removing most studied organic wastewater and pharmaceutical compounds and microbial indicators. Carbamazepine (an anti-convulsant drug) was the only pharmaceutical compound detected in groundwater from two sprayfield monitoring wells (1-2 ppt). One other detection of carbamazepine was found in a distant well water

  11. An Austrian framework for PET quality control

    International Nuclear Information System (INIS)

    Nicoletti, R.; Dobrozemsky, G.; Minear, G.; Bergmann, H.

    2002-01-01

    Full text: The European patient protection directive (97/43 EURATOM) requires regular routine quality control (QC) of PET imaging devices. Since no standards were available covering this area and in order to comply with the directive a joint working party of the Austrian societies of nuclear medicine and of medical physics have developed a set of procedures suitable for both dedicated PET scanners and gamma cameras operating in coincidence mode (GCPET). The routine procedures proposed include both manufacturer recommended procedures and tests for specific parameters and calibration procedures. Wherever possible, procedures adapted or derived from NEMA standards publication NU 2-2001 were used to permit direct comparison with specified parameters of image quality. For dedicated PET scanners the most important procedures are the checking of detector sensitivities and the attenuation calibration scan. With full ring scanners the attenuation calibration scan is a blank scan, with partial ring devices a special attenuation calibration phantom has to be used. Test protocols are specific to manufacturer and scanner type. They are usually performed automatically overnight. In addition, some instruments require special calibrations, e.g. gain adjustments or coincidence timing calibration. GCPET procedures include the frequent assessment in coincidence mode of detector uniformity, energy resolution and system sensitivity. Common to both dedicated PET and GCPET are the regular quarterly assessment of tomographic spatial resolution and the calibration of the system for quantitative measurements. As a total performance test for both systems assessment of image quality following NU 2-2001 was included, to be carried out after major system changes or repairs. The suite of QC procedures was tested on several dedicated PET and GCPET systems including all major manufacturers' systems. Due to missing hardware or software not all tests could be performed on all systems. Some of the

  12. Quality control and characterization of bentonite materials

    International Nuclear Information System (INIS)

    Kiviranta, L.; Kumpulainen, S.

    2011-12-01

    . Thus, in a certain extent, index tests can be used to determine the smectite content indicatively for quality control purposes. Previously set acceptance testing requirement limits for swelling index, liquid limit and CEC should be reconsidered, since Ca-bentonite tested in this study did not fulfill the requirement for swelling index, the previously set liquid limit requirement value was way below the values measured in this study, and because the previously set CEC requirement limits were based on a technique that needed different requirement limits for Na- and Ca-bentonites, on contrary to the method used in this study.(orig.)

  13. Plant-wide modelling of phosphorus transformations in wastewater treatment systems: Impacts of control and operational strategies.

    Science.gov (United States)

    Solon, K; Flores-Alsina, X; Kazadi Mbamba, C; Ikumi, D; Volcke, E I P; Vaneeckhaute, C; Ekama, G; Vanrolleghem, P A; Batstone, D J; Gernaey, K V; Jeppsson, U

    2017-04-15

    The objective of this paper is to report the effects that control/operational strategies may have on plant-wide phosphorus (P) transformations in wastewater treatment plants (WWTP). The development of a new set of biological (activated sludge, anaerobic digestion), physico-chemical (aqueous phase, precipitation, mass transfer) process models and model interfaces (between water and sludge line) were required to describe the required tri-phasic (gas, liquid, solid) compound transformations and the close interlinks between the P and the sulfur (S) and iron (Fe) cycles. A modified version of the Benchmark Simulation Model No. 2 (BSM2) (open loop) is used as test platform upon which three different operational alternatives (A 1 , A 2 , A 3 ) are evaluated. Rigorous sensor and actuator models are also included in order to reproduce realistic control actions. Model-based analysis shows that the combination of an ammonium ( [Formula: see text] ) and total suspended solids (X TSS ) control strategy (A 1 ) better adapts the system to influent dynamics, improves phosphate [Formula: see text] accumulation by phosphorus accumulating organisms (X PAO ) (41%), increases nitrification/denitrification efficiency (18%) and reduces aeration energy (E aeration ) (21%). The addition of iron ( [Formula: see text] ) for chemical P removal (A 2 ) promotes the formation of ferric oxides (X HFO-H , X HFO-L ), phosphate adsorption (X HFO-H,P , X HFO-L,P ), co-precipitation (X HFO-H,P,old , X HFO-L,P,old ) and consequently reduces the P levels in the effluent (from 2.8 to 0.9 g P.m -3 ). This also has an impact on the sludge line, with hydrogen sulfide production ( [Formula: see text] ) reduced (36%) due to iron sulfide (X FeS ) precipitation. As a consequence, there is also a slightly higher energy production (E production ) from biogas. Lastly, the inclusion of a stripping and crystallization unit (A 3 ) for P recovery reduces the quantity of P in the anaerobic digester supernatant

  14. 7 CFR 58.733 - Quality control tests.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Quality control tests. 58.733 Section 58.733... Procedures § 58.733 Quality control tests. (a) Chemical analyses. The following chemical analyses shall be... pasteurization by means of the phosphatase test, as well as any other tests necessary to assure good quality...

  15. Minimal requirements for quality controls in radiotherapy with external beams

    International Nuclear Information System (INIS)

    1999-01-01

    Physical dosimetric guidelines have been developed by the Italian National Institute of Health study group on quality assurance in radiotherapy to define protocols for quality controls in external beam radiotherapy. While the document does not determine strict rules or firm recommendations, it suggests minimal requirements for quality controls necessary to guarantee an adequate degree of accuracy in external beam radiotherapy [it

  16. Performance and quality control of nuclear medicine instrumentation

    International Nuclear Information System (INIS)

    Paras, P.

    1981-01-01

    The status and the recent developments of nuclear medicine instrumentation performance, with an emphasis on gamma-camera performance, are discussed as the basis for quality control. New phantoms and techniques for the measurement of gamma-camera performance parameters are introduced and their usefulness for quality control is discussed. Tests and procedures for dose calibrator quality control are included. Also, the principles of quality control, tests, equipment and procedures for each type of instrument are reviewed, and minimum requirements for an effective quality assurance programme for nuclear medicine instrumentation are suggested. (author)

  17. Instrumentation, control and automation in wastewater - from London 1973 to Narbonne 2013

    DEFF Research Database (Denmark)

    Olsson, G.; Carlsson, B.; Comas, J.

    2014-01-01

    , instrumentation, computer systems and control theory. However, many developments have not been addressed here, such as sewer control, drinking water treatment and water distribution control. It is hoped that this review can stimulate new attempts to more effectively apply control and automation in water systems...

  18. 10 CFR 26.167 - Quality assurance and quality control.

    Science.gov (United States)

    2010-01-01

    ... at the appropriate cutoff concentration for the compound of interest as specified in § 26.161(c) and (f), a control without the compound of interest (i.e., a certified negative control), and at least one control with one of the compounds of interest at a measurable concentration; and (ii) A...

  19. SALE, Quality Control of Analytical Chemical Measurements

    International Nuclear Information System (INIS)

    Bush, W.J.; Gentillon, C.D.

    1985-01-01

    1 - Description of problem or function: The Safeguards Analytical Laboratory Evaluation (SALE) program is a statistical analysis program written to analyze the data received from laboratories participating in the SALE quality control and evaluation program. The system is aimed at identifying and reducing analytical chemical measurement errors. Samples of well-characterized materials are distributed to laboratory participants at periodic intervals for determination of uranium or plutonium concentration and isotopic distributions. The results of these determinations are statistically evaluated and participants are informed of the accuracy and precision of their results. 2 - Method of solution: Various statistical techniques produce the SALE output. Assuming an unbalanced nested design, an analysis of variance is performed, resulting in a test of significance for time and analyst effects. A trend test is performed. Both within- laboratory and between-laboratory standard deviations are calculated. 3 - Restrictions on the complexity of the problem: Up to 1500 pieces of data for each nuclear material sampled by a maximum of 75 laboratories may be analyzed

  20. Quality control chart for crushed granite concrete

    Directory of Open Access Journals (Sweden)

    Ewa E. DESMOND

    2016-07-01

    Full Text Available A chart for assessing in-situ grade (strength of concrete, has been developed in this study. Four grades of concrete after the Nigerian General Specification for Roads and bridges (NGSRB-C20, C25, C30 and C35, is studied at different water-cement ratios for medium and high slump range. The concrete mixes are made from crushed granite rock as coarse aggregate with river sand as fine aggregate. Compression test on specimens are conducted at curing age of 1, 3, 7, 14, 21, 28 and 56 days. Results on concrete workability from slump values, and water-cement ratios revealed that specimens with lower water-cement ratio were less workable but had higher strength, compared to mixes with higher water cement ratio. A simple algorithm using nonlinear regression analysis performed on each experimental data set produced Strength-Age (S-A curves which were used to establish a quality control chart. The accuracy of these curves were evaluated by computing average absolute error (AAS, the error of estimate (EoE and the average absolute error of estimate (Abs EoE for each concrete mix. These were done based on the actual average experimental strengths to measure how close the predicted values are to the experimental data set. The absolute average error of estimate (Abs. EoE recorded was less than ±10% tolerance zone for concrete works.

  1. The IAEA's programme in analytical quality control

    International Nuclear Information System (INIS)

    Suschny, O.

    1980-10-01

    The purpose of the Analytical Quality Control Programme of the International Atomic Energy Agency is to help laboratories in the Agency's Member States to assess and, if necessary, to improve the reliability of their analytical work in areas related to nuclear technology and radioisotope utilisation. This is done by the organisation of analytical intercomparisons and by the provision of certified or uncertified reference materials. Recently intercomparisons have been organised of trace element analysis in a soil and a lake sediment sample which have led to the certification of two new reference materials, SOIL-5 and SL-1 (lake sediment). A technique has been developed to recognise and to remove outlying results. Criteria have been established to classify element-concentration values into the categories ''established with a high degree of confidence'', ''established with a reasonable degree of confidence'' and ''information value only''. Four radionuclide intercomparisons have recently been carried out: W-1/1 and W-2/1 of the determination of selected radionuclides in water and Air-1/1 and Air-2/1 of that of selected radionuclides on simulated air filters. Details of the preparation of materials for these intercomparisons, and of data treatment and some results are discussed in the paper

  2. The quality control theory of aging

    Directory of Open Access Journals (Sweden)

    Warren Ladiges

    2014-05-01

    Full Text Available The quality control (QC theory of aging is based on the concept that aging is the result of a reduction in QC of cellular systems designed to maintain lifelong homeostasis. Four QC systems associated with aging are 1 inadequate protein processing in a distressed endoplasmic reticulum (ER; 2 histone deacetylase (HDAC processing of genomic histones and gene silencing; 3 suppressed AMPK nutrient sensing with inefficient energy utilization and excessive fat accumulation; and 4 beta-adrenergic receptor (BAR signaling and environmental and emotional stress. Reprogramming these systems to maintain efficiency and prevent aging would be a rational strategy for increased lifespan and improved health. The QC theory can be tested with a pharmacological approach using three well-known and safe, FDA-approved drugs: 1 phenyl butyric acid, a chemical chaperone that enhances ER function and is also an HDAC inhibitor, 2 metformin, which activates AMPK and is used to treat type 2 diabetes, and 3 propranolol, a beta blocker which inhibits BAR signaling and is used to treat hypertension and anxiety. A critical aspect of the QC theory, then, is that aging is associated with multiple cellular systems that can be targeted with drug combinations more effectively than with single drugs. But more importantly, these drug combinations will effectively prevent, delay, or reverse chronic diseases of aging that impose such a tremendous health burden on our society.

  3. The quality control theory of aging.

    Science.gov (United States)

    Ladiges, Warren

    2014-01-01

    The quality control (QC) theory of aging is based on the concept that aging is the result of a reduction in QC of cellular systems designed to maintain lifelong homeostasis. Four QC systems associated with aging are 1) inadequate protein processing in a distressed endoplasmic reticulum (ER); 2) histone deacetylase (HDAC) processing of genomic histones and gene silencing; 3) suppressed AMPK nutrient sensing with inefficient energy utilization and excessive fat accumulation; and 4) beta-adrenergic receptor (BAR) signaling and environmental and emotional stress. Reprogramming these systems to maintain efficiency and prevent aging would be a rational strategy for increased lifespan and improved health. The QC theory can be tested with a pharmacological approach using three well-known and safe, FDA-approved drugs: 1) phenyl butyric acid, a chemical chaperone that enhances ER function and is also an HDAC inhibitor, 2) metformin, which activates AMPK and is used to treat type 2 diabetes, and 3) propranolol, a beta blocker which inhibits BAR signaling and is used to treat hypertension and anxiety. A critical aspect of the QC theory, then, is that aging is associated with multiple cellular systems that can be targeted with drug combinations more effectively than with single drugs. But more importantly, these drug combinations will effectively prevent, delay, or reverse chronic diseases of aging that impose such a tremendous health burden on our society.

  4. Quality control culture of diagnostic ultrasound parameters

    International Nuclear Information System (INIS)

    Andam, A.A.B; Addison, E.C.K.; Aggry-Smith, S.; Nani, E.K.

    2003-01-01

    A phantom, consisting of two phases, has been designed and constructed to mimic the human body. The phase one phantom was designed to mimic a a surface lesion in the human body and the phase two phantom designed to mimic a section of the whole body. Ultrasound scans of the phantom were acquired for various material in the phantom at six hospitals in Kumasi, Ghana. A linear array transducer with parallel beams having a convex probe and a 3.5 MHz ultrasound frequency were used to carry out the experiment. It was observed that the depth of penetration of ultrasound, which constitutes the maximum depth of visualization or sensitivity, is determined by the frequency of the transducer, the attenuation of the medium being imaged and the system settings. Uniformity and linearity of the machines investigated were found to be within clinically acceptable standards. Spatial resolution, comprising axial and lateral resolutions, was observed to be satisfactory for the machines tested. It was observed that lateral resolution improved with the narrowing of the beam width. The ultrasound scanners at the selected hospitals were found to be operating at the expected level of performance. This work highlights the importance of putting in place a locally based mechanism for quality control of diagnostic ultrasound machines (author)

  5. QUALITY CONTROL OF SOME TRADITIONAL MEAT PRODUCTS

    Directory of Open Access Journals (Sweden)

    S. DOBRINAS

    2014-03-01

    Full Text Available In this paper, we present the characterization of six traditional meat products: smoked file, smoked bacon, pork sausages, sausage prepared from swine’s entrails, pork pastrami, sheep sausages. Organoleptic tests (the aspect and shape, the aspect of freshly cut in the section, smell, taste and consistency, physico-chemical and microbiological determinations (NTG, Salmonella, Listeria monocytogenes and Escherichia coli were performed. These analyzes are a part of quality control that must be done in order to obtain a certificate from the Ministry of Agriculture for a traditional product. After identification of H2S and starch and according to fat oxidation degree it was concluded that analyzed samples didn’t contain counterfeiters and all parameters analyzed are within the maximum limits allowed by law. Considering all the procedures for manufacturing, characteristics of raw and auxiliary materials, organoleptic properties of final products analyzed in this study, it can be concluded that analyzed meat specialties meet the requirements of Ministry Order no. 690/28.09.2004 for the traditional products certification.

  6. Bacterial lipoproteins; biogenesis, sorting and quality control.

    Science.gov (United States)

    Narita, Shin-Ichiro; Tokuda, Hajime

    2017-11-01

    Bacterial lipoproteins are a subset of membrane proteins localized on either leaflet of the lipid bilayer. These proteins are anchored to membranes through their N-terminal lipid moiety attached to a conserved Cys. Since the protein moiety of most lipoproteins is hydrophilic, they are expected to play various roles in a hydrophilic environment outside the cytoplasmic membrane. Gram-negative bacteria such as Escherichia coli possess an outer membrane, to which most lipoproteins are sorted. The Lol pathway plays a central role in the sorting of lipoproteins to the outer membrane after lipoprotein precursors are processed to mature forms in the cytoplasmic membrane. Most lipoproteins are anchored to the inner leaflet of the outer membrane with their protein moiety in the periplasm. However, recent studies indicated that some lipoproteins further undergo topology change in the outer membrane, and play critical roles in the biogenesis and quality control of the outer membrane. This article is part of a Special Issue entitled: Bacterial Lipids edited by Russell E. Bishop. Copyright © 2016 Elsevier B.V. All rights reserved.

  7. Factors affecting reuse of wastewater

    Energy Technology Data Exchange (ETDEWEB)

    Haraszti, L

    1981-01-01

    Changing the quality of circulating water, raising the effectiveness of sedimentation, examples of biological treatment of wastewater are presented. The necessity of continuing the studies on biological treatment of wastewater is demonstrated. It is considered useful to define the importance of KhPK and BP5 in each case. During biological treatment in ponds, to define the relation BPK5:N:P, research on conditions for nutrient removal must be done. To do this, as well as decrease the significance of KhPK, a mathematical model for defining the effectiveness of biological treatment of wastewater and consequently their reuse must be developed.

  8. An innovative concept for handling and operation of the wastewater treatment plant of Cottbus

    International Nuclear Information System (INIS)

    Spiller, K.; Schmitt, J.

    1994-01-01

    A new concept for handling and operating the wastewater treatment plant of Cottbus, with computerized modelling and an expert system as integral parts of process analysis and decision-making, is developed. Optimized plant operation and process stability is to be achieved by conrolling process-dependent dosage of wastewater coming from sludge treatment and from faecal wastewater. With the treatment plant still being built, a thorough analysis of the influent and the resulting process conditions is done, using the computerized model. Results and consequences for process optimization are presented in this article. Special attention has to be given to load smoothing and optimization of denitrification, influencing process stability and quality. Thereby not only the legal requirements can be fulfilled but improvement of effluent quality also could be achieved, reducing total nitrogen in the effluent by as much as 50%, lowering wastewater treatment costs by allowing lower control levels and fees to be payed. (orig.) [de

  9. Quality assurance and quality control of nuclear analytical techniques

    International Nuclear Information System (INIS)

    Cincu, Emanuelathor

    2001-01-01

    Test and analytical laboratories in East and Central European countries need to prove the reliability and credibility of their economic, environmental, medical and legal decisions and their capacity of issuing reliable, verifiable reports. These demands imposed by the European Union aimed at avoiding a possible barrier to trade for the developing countries. In June 1999, in order to help Member States to develop according to EU objectives and the overall situation of the European market, IAEA launched a new co-operation programme designed to help the nuclear analytical laboratories in nuclear institutions and universities of Member States by training in the use of some Nuclear Analytical Techniques (NAT) that include: alpha, beta and gamma-ray spectrometry, radiochemical and neutron activation analysis, total reflection X-ray fluorescence. The Regional IAEA Project, named 'Quality Assurance/Quality Control of Nuclear Analytical Techniques' (NAT) aims at implementing the QA principles via a system of defined consecutive steps leading to a level on which the QA system is self-sustainable for formal accreditation or certification and satisfies the EU technical performance criteria; the requirements are in accordance with the new ISO/IEC 17025 Standard/Dec.1999 'General requirements for the competence of testing and calibration laboratories' - First edition. The Horia Hulubei National Institute for Nuclear Physics and Engineering, IFIN-HH, was admitted for participation in the IAEA Project in June 1999 account taken of its experience in the QA and metrology fields and its performance in the fields of beta and gamma-ray spectrometry, and radiochemical and neutron activation analysis, employed in both basic research and applications for external clients. Two working groups of specialists with the QA and Standardization and Metrology Departments and six analytical groups with the departments of Nuclear Applied Physics, Life Physics and Ionising Radiation Metrology are

  10. Mitochondrial quality control pathways as determinants of metabolic health

    NARCIS (Netherlands)

    Held, Ntsiki M.; Houtkooper, Riekelt H.

    2015-01-01

    Mitochondrial function is key for maintaining cellular health, while mitochondrial failure is associated with various pathologies, including inherited metabolic disorders and age-related diseases. In order to maintain mitochondrial quality, several pathways of mitochondrial quality control have

  11. Concrete and steel construction quality control and assurance

    CERN Document Server

    El-Reedy, Mohamed A

    2014-01-01

    Starting with the receipt of materials and continuing all the way through to the final completion of the construction phase, Concrete and Steel Construction: Quality Control and Assurance examines all the quality control and assurance methods involving reinforced concrete and steel structures. This book explores the proper ways to achieve high-quality construction projects, and also provides a strong theoretical and practical background. It introduces information on quality techniques and quality management, and covers the principles of quality control. The book presents all of the quality control and assurance protocols and non-destructive test methods necessary for concrete and steel construction projects, including steel materials, welding and mixing, and testing. It covers welding terminology and procedures, and discusses welding standards and procedures during the fabrication process, as well as the welding codes. It also considers the total quality management system based on ISO 9001, and utilizes numer...

  12. Assessing potential impacts of a wastewater rapid infiltration basin system on groundwater quality: a delaware case study.

    Science.gov (United States)

    Andres, A S; Sims, J Thomas

    2013-01-01

    Rapid infiltration basin systems (RIBS) are receiving increased interest for domestic wastewater disposal in rural areas. They rely on natural treatment processes to filter pollutants and use extremely high effluent loading rates, much greater than natural precipitation, applied to a small geographic area instead of disposal to surface water. Concerns exist today that adopting RIBS in areas with shallow groundwater and sandy soils may increase ground and surface water pollution. We conducted a field study of RIBS effects on N and P concentrations in soils and groundwater at Cape Henlopen State Park, Delaware, where a RIBS designed and operated following USEPA guidance has been used for >25 yr. Site and wastewater characteristics (water table of 8 m, Fe- and Al-oxide coatings on soils, organic-rich effluent) were favorable for denitrification and P sorption; however, we found high P saturation, reduced soil P sorption capacity, and significant total P accumulation at depths >1.5 m, factors that could lead to dissolved P leaching. Very low soil inorganic N levels suggest that wastewater N was converted rapidly to NO-N and leached from the RIBS. Extensive groundwater monitoring supported these concerns and showed rapid offsite transport of N and P at concentrations similar to the effluent. Results suggest that high hydraulic loads and preferential flow led to flow velocities that were too large, and contact times between effluent and soils that were too short, for effective N and P attenuation processes. These findings indicate the need for better site characterization and facility designs to reduce and monitor contaminant loss from RIBS in similar settings. Copyright © by the American Society of Agronomy, Crop Science Society of America, and Soil Science Society of America, Inc.

  13. Descriptive study of the quality control in mammography

    International Nuclear Information System (INIS)

    Gaona, E.; Perdigon C, G.M.; Casian C, G.A.; Azorin N, J.; Diaz G, J.A.I.; Arreola, M.

    2005-01-01

    The goal of mammography is to provide contrast between a lesion that is possible residing within the breast and normal surrounding tissue. Quality control is essential for maintaining the contrast imaging performance of a mammography system and incorporate tests that are relevant in that they are predictive of future degradation of contrast imaging performance. These tests will also be done at frequency that is high enough to intercept most drifts in quality imaging or performance before they become diagnostically significant. The quality control study has as objective to describe the results of the assessment of quality imaging elements (film optical density, contrast (density difference), uniformity, resolution and noise) of 62 mammography departments without quality control program and comparison these results with a mammography reference department with a quality control program. When comparing the results they allow seeing the clinical utility of to have a quality control program to reduce the errors of mammography interpretation. (Author)

  14. Water quality-based real time control of integrated urban drainage: a preliminary study from Copenhagen, Denmark

    DEFF Research Database (Denmark)

    Vezzaro, Luca; Lund Christensen, Margit; Thirsing, Carsten

    2013-01-01

    Global Real Time Control (RTC) of urban drainage systems is increasingly seen as cost-effective solution for responding to increasing performance demands. This study investigated the potential for including water-quality based RTC into the global control strategy which is under implementation...... in the Lynetten catchment (Copenhagen, Denmark). Two different strategies were simulated, considering: (i) water quality at the wastewater treatment plant (WWTP) inlet and (ii) pollution discharge to the bathing areas. These strategies were included in the Dynamic Overflow Risk Assessment (DORA) RTC strategy......, which allows for prioritization of the discharge points in the systems according to their sensitivity. A conceptual hydrological model was used to assess the performance of the integrated control strategy over an entire year. The simulation results showed the benefits of the proposed approaches...

  15. Analytical approaches to quality assurance and quality control in rangeland monitoring data

    Science.gov (United States)

    Producing quality data to support land management decisions is the goal of every rangeland monitoring program. However, the results of quality assurance (QA) and quality control (QC) efforts to improve data quality are rarely reported. The purpose of QA and QC is to prevent and describe non-sampling...

  16. Title IV Quality Control Project, Stage II. Management Option II: Delivery System Quality Improvements.

    Science.gov (United States)

    Advanced Technology, Inc., Reston, VA.

    Stage Two of the Title IV Quality Control Project is an integrated study of quality in five related Federal financial aid programs for postsecondary students. Section 1 of the paper establishes a framework for defining quality improvements, in order to identify the types of changes that would tend to improve quality across all facets of the…

  17. 7 CFR 58.442 - Laboratory and quality control tests.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Laboratory and quality control tests. 58.442 Section... Service 1 Operations and Operating Procedures § 58.442 Laboratory and quality control tests. (a) Chemical... Methods or by other methods giving equivalent results. (b) Weight or volume control. Representative...

  18. Introduction to Quality Control in a Compounding Pharmacy.

    Science.gov (United States)

    Allen, Loyd V

    2016-01-01

    A quality-based program is vital in every compounding pharmacy to ensure that each preparation is compounded properly and is stable for its expected duration of use. This article discusses quality control, quality assurance, continuous quality improvement, and also describes the components of an in-house (in-pharmacy) quality program, as well as the role of outside laboratories. Copyright© by International Journal of Pharmaceutical Compounding, Inc.

  19. Notification: EPA Region 10 Management Controls Over Allowing Substantial Public Funds to Construct the Spokane County Wastewater Treatment Facility

    Science.gov (United States)

    January 20, 2012. This EPA's OIG is initiating a review from an OIG hotline complaint regarding whether federal funds were properly used to construct the new Spokane County wastewater treatment facility in accordance with 40 CFR 35, Subpart K.

  20. Implementing self sustained quality control procedures in a clinical laboratory.

    Science.gov (United States)

    Khatri, Roshan; K C, Sanjay; Shrestha, Prabodh; Sinha, J N

    2013-01-01

    Quality control is an essential component in every clinical laboratory which maintains the excellence of laboratory standards, supplementing to proper disease diagnosis, patient care and resulting in overall strengthening of health care system. Numerous quality control schemes are available, with combinations of procedures, most of which are tedious, time consuming and can be "too technical" whereas commercially available quality control materials can be expensive especially for laboratories in developing nations like Nepal. Here, we present a procedure performed at our centre with self prepared control serum and use of simple statistical tools for quality assurance. The pooled serum was prepared as per guidelines for preparation of stabilized liquid quality control serum from human sera. Internal Quality Assessment was performed on this sample, on a daily basis which included measurement of 12 routine biochemical parameters. The results were plotted on Levey-Jennings charts and analysed with quality control rules, for a period of one month. The mean levels of biochemical analytes in self prepared control serum were within normal physiological range. This serum was evaluated every day along with patients' samples. The results obtained were plotted on control charts and analysed using common quality control rules to identify possible systematic and random errors. Immediate mitigation measures were taken and the dispatch of erroneous reports was avoided. In this study we try to highlight on a simple internal quality control procedure which can be performed by laboratories, with minimum technology, expenditure, and expertise and improve reliability and validity of the test reports.

  1. The results of a quality-control programme in mammography

    International Nuclear Information System (INIS)

    Ramsdale, M.L.; Hiles, P.A.

    1989-01-01

    With the introduction of a breast screening programme in the UK, quality assurance in mammography is of paramount importance in assuring optimum imaging performance with low dose. Quality control checks are an essential part of the quality-assurance system. A quality-control programme at a breast screening clinic is described. Daily checks include film sensitometry for X-ray processor control and radiography of a lucite phantom to monitor the consistency of the X-ray machine automatic exposure control. Weekly checks include additional measurements on the performance of the automatic exposure control for different breast thickness and an overall assessment of image quality using a prototype mammography test phantom. The test phantom measures low-contrast sensitivity, high-contrast resolution and small-detail visibility. The results of the quality-control programme are presented with particular attention paid to tolerances and limiting values. (author)

  2. Quality control with R an ISO standards approach

    CERN Document Server

    Cano, Emilio L; Prieto Corcoba, Mariano

    2015-01-01

    Presenting a practitioner's guide to capabilities and best practices of quality control systems using the R programming language, this volume emphasizes accessibility and ease-of-use through detailed explanations of R code as well as standard statistical methodologies. In the interest of reaching the widest possible audience of quality-control professionals and statisticians, examples throughout are structured to simplify complex equations and data structures, and to demonstrate their applications to quality control processes, such as ISO standards. The volume balances its treatment of key aspects of quality control, statistics, and programming in R, making the text accessible to beginners and expert quality control professionals alike. Several appendices serve as useful references for ISO standards and common tasks performed while applying quality control with R.

  3. Treatment of highly concentrated tannery wastewater using electrocoagulation: Influence of the quality of aluminium used for the electrode

    International Nuclear Information System (INIS)

    Elabbas, S.; Ouazzani, N.; Mandi, L.; Berrekhis, F.; Perdicakis, M.; Pontvianne, S.; Pons, M-N.; Lapicque, F.; Leclerc, J-P

    2016-01-01

    Highlights: • COD and Cr(III) species can be simultaneously removed by electrocoagulation. • Cu-containing Al alloy is more efficient than pure Al as electrodes. • Dilution of too concentrated tannery wastewater is required for efficient treatment. - Abstract: This paper deals with the ability of electrocoagulation (EC) to remove simultaneously COD and chromium from a real chrome tanning wastewater in a batch stirred electro-coagulation cell provided with two aluminium-based electrodes (aluminium/copper/magnesium alloy and pure aluminium). Effects of operating time, current density and initial concentration of Cr(III) and COD have been investigated. The concentrations of pollutants have been successfully reduced to environmentally acceptable levels even if the concentrated effluent requires a long time of treatment of around 6 h with a 400 A/m"2 current density. The aluminium alloy was found to be more efficient than pure aluminium for removal of COD and chromium. Dilution of the waste has been tested for treatment: high abatement levels could be obtained with shorter time of treatment and lower current densities. Energy consumption of the electrocoagulation process was also discussed. The dilution by half of the concentrated waste leads to a higher abatement performance of both COD and chromium with the best energy efficiency.

  4. Treatment of highly concentrated tannery wastewater using electrocoagulation: Influence of the quality of aluminium used for the electrode

    Energy Technology Data Exchange (ETDEWEB)

    Elabbas, S.; Ouazzani, N.; Mandi, L. [Laboratoire d’Hydrobiologie, Ecotoxicologie et Assainissement (LHEA, URAC 33), Faculté de Sciences Semlalia, BP 2390, Université Cadi Ayyad, Marrakech (Morocco); Centre National d’Etude et de Recherche sur l’Eau et l’Energie (CNEREE), Université Cadi Ayyad, BP 511, Marrakech (Morocco); Berrekhis, F. [Equipe de Physico-chimie des Matériaux, Ecole Normale Supérieure, Université Cadi Ayyad, BP 2400, 40000 Marrakech (Morocco); Perdicakis, M. [Laboratoire de Chimie Physique et Microbiologie pour l’Environnement (LCPME) UMR 7564, Université de Lorraine—CNRS, 405 rue de Vandoeuvre, F-54602 Villers-lès Nancy Cedex (France); Pontvianne, S.; Pons, M-N.; Lapicque, F. [Laboratoire Réactions et Génie des Procédés (LRGP) UMR 7274, CNRS, Université de Lorraine, 1 rue Grandville, BP 20451, 54001 Nancy cedex (France); Leclerc, J-P, E-mail: jean-pierre.leclerc@univ-lorraine.fr [Laboratoire Réactions et Génie des Procédés (LRGP) UMR 7274, CNRS, Université de Lorraine, 1 rue Grandville, BP 20451, 54001 Nancy cedex (France)

    2016-12-05

    Highlights: • COD and Cr(III) species can be simultaneously removed by electrocoagulation. • Cu-containing Al alloy is more efficient than pure Al as electrodes. • Dilution of too concentrated tannery wastewater is required for efficient treatment. - Abstract: This paper deals with the ability of electrocoagulation (EC) to remove simultaneously COD and chromium from a real chrome tanning wastewater in a batch stirred electro-coagulation cell provided with two aluminium-based electrodes (aluminium/copper/magnesium alloy and pure aluminium). Effects of operating time, current density and initial concentration of Cr(III) and COD have been investigated. The concentrations of pollutants have been successfully reduced to environmentally acceptable levels even if the concentrated effluent requires a long time of treatment of around 6 h with a 400 A/m{sup 2} current density. The aluminium alloy was found to be more efficient than pure aluminium for removal of COD and chromium. Dilution of the waste has been tested for treatment: high abatement levels could be obtained with shorter time of treatment and lower current densities. Energy consumption of the electrocoagulation process was also discussed. The dilution by half of the concentrated waste leads to a higher abatement performance of both COD and chromium with the best energy efficiency.

  5. 42 CFR 84.256 - Quality control requirements.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Quality control requirements. 84.256 Section 84.256... § 84.256 Quality control requirements. (a) In addition to the construction and performance requirements specified in §§ 84.251, 84.252, 84.253, 84.254, and 84.255, the quality control requirements in paragraphs...

  6. Internal quality control of RIA with Tonks error calculation method

    International Nuclear Information System (INIS)

    Chen Xiaodong

    1996-01-01

    According to the methodology feature of RIA, an internal quality control chart with Tonks error calculation method which is suitable for RIA is designed. The quality control chart defines the value of the allowance error with normal reference range. The method has the simplicity of its performance and directly perceived through the senses. Taking the example of determining T 3 and T 4 , the calculation of allowance error, drawing of quality control chart and the analysis of result are introduced

  7. Proteomics Quality Control: Quality Control Software for MaxQuant Results.

    Science.gov (United States)

    Bielow, Chris; Mastrobuoni, Guido; Kempa, Stefan

    2016-03-04

    Mass spectrometry-based proteomics coupled to liquid chromatography has matured into an automatized, high-throughput technology, producing data on the scale of multiple gigabytes per instrument per day. Consequently, an automated quality control (QC) and quality analysis (QA) capable of detecting measurement bias, verifying consistency, and avoiding propagation of error is paramount for instrument operators and scientists in charge of downstream analysis. We have developed an R-based QC pipeline called Proteomics Quality Control (PTXQC) for bottom-up LC-MS data generated by the MaxQuant software pipeline. PTXQC creates a QC report containing a comprehensive and powerful set of QC metrics, augmented with automated scoring functions. The automated scores are collated to create an overview heatmap at the beginning of the report, giving valuable guidance also to nonspecialists. Our software supports a wide range of experimental designs, including stable isotope labeling by amino acids in cell culture (SILAC), tandem mass tags (TMT), and label-free data. Furthermore, we introduce new metrics to score MaxQuant's Match-between-runs (MBR) functionality by which peptide identifications can be transferred across Raw files based on accurate retention time and m/z. Last but not least, PTXQC is easy to install and use and represents the first QC software capable of processing MaxQuant result tables. PTXQC is freely available at https://github.com/cbielow/PTXQC .

  8. A Total Quality-Control Plan with Right-Sized Statistical Quality-Control.

    Science.gov (United States)

    Westgard, James O

    2017-03-01

    A new Clinical Laboratory Improvement Amendments option for risk-based quality-control (QC) plans became effective in January, 2016. Called an Individualized QC Plan, this option requires the laboratory to perform a risk assessment, develop a QC plan, and implement a QC program to monitor ongoing performance of the QC plan. Difficulties in performing a risk assessment may limit validity of an Individualized QC Plan. A better alternative is to develop a Total QC Plan including a right-sized statistical QC procedure to detect medically important errors. Westgard Sigma Rules provides a simple way to select the right control rules and the right number of control measurements. Copyright © 2016 Elsevier Inc. All rights reserved.

  9. The results of a quality-control programme in mammography

    International Nuclear Information System (INIS)

    Ramsdale, M.L.; Hiles, P.A.

    1989-01-01

    A quality-control programme at a breast screening clinic is described. Daily checks include film sensitometry for X-ray processor control and radiography of a lucite phantom to monitor the consistency of the X-ray machine automatic exposure control. Weekly checks include additional measurements on the performance of the automatic exposure control for different breast thickness and an overall assessment of image quality using a prototype mammography test phantom. The test phantom measures low-contrast sensitivity, high-control resolution and small-detail visibility. The results of the quality-control programme are presented with particular attention paid to tolerances and limiting values. (author)

  10. Production and characterization of scum and its role in odour control in UASB reactors treating domestic wastewater.

    Science.gov (United States)

    Souza, C L; Silva, S Q; Aquino, S F; Chernicharo, C A L

    2006-01-01

    There are few studies in the literature that have aimed at characterizing the physical, chemical, and microbial aspects of scum produced in UASB reactors. In addition, there is little information on the influence of operational conditions of UASB reactors on scum formation, and the present work addresses these issues. Three demo-scale UASB reactors, fed on domestic wastewater, were employed to monitor the formation and its characteristics. Scum production was periodically assessed during different operational phases, and its characterization involved analyses of BOD, COD, solids, sulfide, sulfate, microscopic observations, as well as biodegradability tests. The results show that the scum formed was physically, chemically, and microscopically similar in both geminated reactors, being comprised mainly of organic material of low biodegradability. Several bacterial morphotypes, mainly filaments and rods, with internal sulfur granules, were observed, and the aerobic microorganisms that developed at the scum layer as a result of photosynthetic activity of cyanobacteria, seemed to play an important role in sulfide removal and odour control. Scum production rates were similar in both reactors, but the imposed higher upflow velocities resulted in a higher production rate and in a reduced biodegradability of the scum.

  11. Effect of surfactant-coated iron oxide nanoparticles on the effluent water quality from a simulated sequencing batch reactor treating domestic wastewater

    International Nuclear Information System (INIS)

    Hwang, Sangchul; Martinez, Diana; Perez, Priscilla; Rinaldi, Carlos

    2011-01-01

    This study was conducted to evaluate the effect of commercially available engineered iron oxide nanoparticles coated with a surfactant (ENP Fe-surf ) on effluent water quality from a lab-scale sequencing batch reactor as a model secondary biological wastewater treatment. Results showed that ∼8.7% of ENP Fe-surf applied were present in the effluent stream. The stable presence of ENP Fe-surf was confirmed by analyzing the mean particle diameter and iron concentration in the effluent. Consequently, aqueous ENP Fe-surf deteriorated the effluent water quality at a statistically significant level (p Fe-surf would be introduced into environmental receptors through the treated effluent and could potentially impact them. - Highlights: → Surfactant-coated engineered iron oxide nanoparticles (ENP Fe-surf ) were assessed. → Effluent quality was analyzed from a sequencing batch reactor with ENP Fe-surf . → ∼8.7% of ENP Fe-surf applied was present in the effluent. → ENP Fe-surf significantly (p Fe-surf will be introduced into environmental receptors. - Stable presence of surfactant-coated engineered iron oxides nanoparticles deteriorated the effluent water quality at a statistically significant level (p < 0.05).

  12. General Quality Control (QC) Guidelines for SAM Methods

    Science.gov (United States)

    Learn more about quality control guidelines and recommendations for the analysis of samples using the methods listed in EPA's Selected Analytical Methods for Environmental Remediation and Recovery (SAM).

  13. Intra- and Intercellular Quality Control Mechanisms of Mitochondria

    Directory of Open Access Journals (Sweden)

    Yoshimitsu Kiriyama

    2017-12-01

    Full Text Available Mitochondria function to generate ATP and also play important roles in cellular homeostasis, signaling, apoptosis, autophagy, and metabolism. The loss of mitochondrial function results in cell death and various types of diseases. Therefore, quality control of mitochondria via intra- and intercellular pathways is crucial. Intracellular quality control consists of biogenesis, fusion and fission, and degradation of mitochondria in the cell, whereas intercellular quality control involves tunneling nanotubes and extracellular vesicles. In this review, we outline the current knowledge on the intra- and intercellular quality control mechanisms of mitochondria.

  14. Quality control system response to stochastic growth of amyloid fibrils

    DEFF Research Database (Denmark)

    Pigolotti, S.; Lizana, L.; Sneppen, K.

    2013-01-01

    We introduce a stochastic model describing aggregation of misfolded proteins and degradation by the protein quality control system in a single cell. Aggregate growth is contrasted by the cell quality control system, that attacks them at different stages of the growth process, with an efficiency...... that decreases with their size. Model parameters are estimated from experimental data. Two qualitatively different behaviors emerge: a homeostatic state, where the quality control system is stable and aggregates of large sizes are not formed, and an oscillatory state, where the quality control system...

  15. The study on quality control of bedside CR examination

    International Nuclear Information System (INIS)

    Yang Xufeng; Luo Xiaomei; Xu Qiaolan; Wu Tengfang; Wen Xingwei

    2007-01-01

    Objective: To study the quality controll of bedside CR examination and improves the imaging quality. Methods: X-ray examination with CR system were performed on 3,300 patients. All CR cassettes were encoded. The imaging plate and cassettes were cleaned regularly. Results: With and without quality control, the percentage of first-rate film was 58.2% and 51%, the second-rate film was 40% and 45.5%, the third-rate film was 1.3% and 2%, respectively. Corxespondingly, the ratio of re-examination decreased from 1.5% to 0.5% after quality control, and imaging quality was stable. Conclusion: The quality control of bedside CR examination can improve the image quality as well as lighten the labor of radiographers. (authors)

  16. Secondary Control for Voltage Quality Enhancement in Microgrids

    DEFF Research Database (Denmark)

    Savaghebi, Mehdi; Jalilian, Alireza; Vasquez, Juan Carlos

    2012-01-01

    In this paper, a hierarchical control scheme is proposed for enhancement of sensitive load bus (SLB) voltage quality in microgrids. The control structure consists of primary and secondary levels. The primary control level comprises distributed generators (DGs) local controllers. Each of these con......In this paper, a hierarchical control scheme is proposed for enhancement of sensitive load bus (SLB) voltage quality in microgrids. The control structure consists of primary and secondary levels. The primary control level comprises distributed generators (DGs) local controllers. Each...

  17. Teaching Quality Control with Chocolate Chip Cookies

    Science.gov (United States)

    Baker, Ardith

    2014-01-01

    Chocolate chip cookies are used to illustrate the importance and effectiveness of control charts in Statistical Process Control. By counting the number of chocolate chips, creating the spreadsheet, calculating the control limits and graphing the control charts, the student becomes actively engaged in the learning process. In addition, examining…

  18. Quality-control design for surface-water sampling in the National Water-Quality Network

    Science.gov (United States)

    Riskin, Melissa L.; Reutter, David C.; Martin, Jeffrey D.; Mueller, David K.

    2018-04-10

    The data-quality objectives for samples collected at surface-water sites in the National Water-Quality Network include estimating the extent to which contamination, matrix effects, and measurement variability affect interpretation of environmental conditions. Quality-control samples provide insight into how well the samples collected at surface-water sites represent the true environmental conditions. Quality-control samples used in this program include field blanks, replicates, and field matrix spikes. This report describes the design for collection of these quality-control samples and the data management needed to properly identify these samples in the U.S. Geological Survey’s national database.

  19. Control of Bank Consolidated Financial Statements Quality

    OpenAIRE

    Margarita S. Ambarchyan

    2013-01-01

    The author presents the multiple linear regression model of bank consolidated financial statements quality. The article considers six characteristics that can be used to estimate the level of bank consolidated financial statements quality. The multiple linear regression model was developed, using the results of point-based system of consolidated financial statements of thirty European bank and financial groups on the basis of the developed characteristics. The author offers to use the charact...

  20. Quality control of recycled asphaltic concrete : final report.

    Science.gov (United States)

    1982-07-01

    This study examined the variations found in recycled asphaltic concrete mix based upon plant quality control data and verification testing. The data was collected from four recycled hot-mix projects constructed in 1981. All plant control and acceptan...

  1. Quality control of sputum microscopic examinations for acid fast ...

    African Journals Online (AJOL)

    Preferred Customer

    in the Southern Region of Ethiopia, and quality control has been initiated as part of this effort. Objective: To evaluate the ... National Tuberculosis and Leprosy Control Programme. (TLCP) manual for ..... laboratories in Mexico. Int J Tuberc Lung ...

  2. METHODS OF AUTOMATIC QUALITY CONTROL OF AGGLUTINANTSANDS IN FOUNDRY

    Directory of Open Access Journals (Sweden)

    D. M. Kukuj

    2004-01-01

    Full Text Available The article is dedicated to comparative analysis of the well-known methods of automatic quality control of agglutinant sands in process of their preparation and to the problems of automation control of the mix preparation processes.

  3. Managing Air Quality - Multi-Pollutant Planning and Control

    Science.gov (United States)

    Describes how planning controls for multiple pollutants at the same time can save money and time and achieve significant benefits, and how control strategies can address both climate change and air quality.

  4. AUTOMATION OF THE SYSTEM OF INTERNAL LABORATORY QUALITY CONTROL

    Directory of Open Access Journals (Sweden)

    V. Z. Stetsyuk

    2015-05-01

    Full Text Available Quality control system base d on the principles of standardi zation of all phases of laboratory testing and analysis of internal laboratory quality control and external quality assessment. For the detection accuracy of the results of laboratory tests, carried out internally between the laboratory and laboratory quality control. Under internal laboratory quality control we understand measurement results of each analysis in each anal ytical series rendered directly in the lab every day. The purpose of internal laboratory control - identifying and eliminating unacceptable deviations from standard perfor mance test in the laboratory, i.e. identifying and eliminating harmful analytical errors. The solutions to these problems by implementing automated systems - software that allows you to optimize analytical laboratory research stage of the procedure by automatically creating process control charts was shown.

  5. Food and Nutrition Services Quality Control Management Program.

    Science.gov (United States)

    Wimsatt-Fraim, Teresa S.

    A program was conducted to improve the quality of food service through the training of 44 food and nutrition service employees in a 200-bed hospital. A 12-week quality control program was implemented to address four key areas: food temperatures, food accuracy, food quality, and dietary personnel. Learning strategies, emphasizing critical thinking…

  6. The process of managerial control in quality improvement initiatives.

    Science.gov (United States)

    Slovensky, D J; Fottler, M D

    1994-11-01

    The fundamental intent of strategic management is to position an organization with in its market to exploit organizational competencies and strengths to gain competitive advantage. Competitive advantage may be achieved through such strategies as low cost, high quality, or unique services or products. For health care organizations accredited by the Joint Commission on Accreditation of Healthcare Organizations, continually improving both processes and outcomes of organizational performance--quality improvement--in all operational areas of the organization is a mandated strategy. Defining and measuring quality and controlling the quality improvement strategy remain problematic. The article discusses the nature and processes of managerial control, some potential measures of quality, and related information needs.

  7. Quality control of commercial bovine lactoferrin.

    Science.gov (United States)

    Wakabayashi, Hiroyuki; Yamauchi, Koji; Abe, Fumiaki

    2018-06-01

    Herein we review commercial bovine lactoferrin quality issues by describing an example of industrial production, the current status of global quality standardization, and quality-activity concerns for further discussion. Morinaga Milk Industry has been industrially producing bovine lactoferrin in Milei GmbH, Germany, since 1989. We delineate its production and quality as an example of safe and high-quality manufacturing. Currently, global standardization in the quality of bovine lactoferrin is progressing through Novel Food and GRAS in the EU and USA, respectively. Novel Food was applied or notified to seven lactoferrin manufacturers and GRAS was notified to three manufacturers, two of which are for infant use and one is for adult use, by the end of 2017. The specifications of these regulations are relatively high, including more than 95% lactoferrin purity in protein, which means that such companies can supply relatively high-grade lactoferrin. There appear to be several concerns regarding lactoferrin quality affecting activities, including contamination of lipopolysaccharide (LPS) and angiogenin, purity, and degradation of lactoferrin sample. Although LPS is immunologically toxic when invading the body, it is distributed normally in foods and the gut. However, an industrial lactoferrin sample may contain LPS at a maximum LPS/lactoferrin molecule ratio = 1/1724, which means 99.9% of the lactoferrin molecule is LPS-free. It is difficult to speculate that LPS contained in a lactoferrin sample affects its activities. Finally in order to achieve good and reproducible results, we make proposals to researchers a use of high-grade lactoferrin, careful storage, and indication the manufacturers' names and specifications in the paper.

  8. In-line coagulation prior to UF of treated domestic wastewater - foulants removal, fouling control and phosphorus removal

    KAUST Repository

    Zheng, Xing; Plume, Stephan; Ernst, Mathias; Croue, Jean-Philippe; Jekel, Martin R.

    2012-01-01

    The present work investigated fouling control and phosphorus removal by applying in-line coagulation prior to ultrafiltration (UF) of treated domestic wastewater. Experiments were conducted in both lab- and pilot-scale under close to neutral pH condition. Lab-scale foulant removal tests showed that increasing the dosage of FeCl3, AlCl3 and polymeric aluminum chloride (PACl) can improve biopolymer removal. Specifically, PACl reduced preferentially the proteinaceous fraction of biopolymer while the other two coagulants showed no significant preference. The filterability of water samples was improved after coagulation, which is contributed to biopolymer removal and the formation of larger particles. Pilot UF experiments demonstrated that in-line coagulation improved the performance of UF to a large extent. Within 0.037-0.148mmol Me3+/L dosage range, adding more FeCl3 and AlCl3 slowed down the development of trans-membrane pressure (TMP) correspondingly, while changing PACl dosage showed little effect on the variation of TMP increase rate. Further investigations indicated that PACl related precipitates contributed to more irreversible fouling than that which the monomeric coagulants made. Fouling control is thus considered as a co-effect determined by foulant removal efficiency, fouling layer structure and the adherence of hydrolysis products/precipitates onto the membrane. With respect to phosphorus removal, dosing FeCl3 and AlCl3 achieved higher removal efficiency than using PACl. Based on lab- and pilot-scale results, dosing FeCl3 and AlCl3 at a relative dosage of over 2.5mol Me3+ per mol total phosphorus (TP) in feedwater is necessarily required to keep the TP concentration under 50μg/L in UF permeate. © 2012 Elsevier B.V.

  9. In-line coagulation prior to UF of treated domestic wastewater - foulants removal, fouling control and phosphorus removal

    KAUST Repository

    Zheng, Xing

    2012-06-01

    The present work investigated fouling control and phosphorus removal by applying in-line coagulation prior to ultrafiltration (UF) of treated domestic wastewater. Experiments were conducted in both lab- and pilot-scale under close to neutral pH condition. Lab-scale foulant removal tests showed that increasing the dosage of FeCl3, AlCl3 and polymeric aluminum chloride (PACl) can improve biopolymer removal. Specifically, PACl reduced preferentially the proteinaceous fraction of biopolymer while the other two coagulants showed no significant preference. The filterability of water samples was improved after coagulation, which is contributed to biopolymer removal and the formation of larger particles. Pilot UF experiments demonstrated that in-line coagulation improved the performance of UF to a large extent. Within 0.037-0.148mmol Me3+/L dosage range, adding more FeCl3 and AlCl3 slowed down the development of trans-membrane pressure (TMP) correspondingly, while changing PACl dosage showed little effect on the variation of TMP increase rate. Further investigations indicated that PACl related precipitates contributed to more irreversible fouling than that which the monomeric coagulants made. Fouling control is thus considered as a co-effect determined by foulant removal efficiency, fouling layer structure and the adherence of hydrolysis products/precipitates onto the membrane. With respect to phosphorus removal, dosing FeCl3 and AlCl3 achieved higher removal efficiency than using PACl. Based on lab- and pilot-scale results, dosing FeCl3 and AlCl3 at a relative dosage of over 2.5mol Me3+ per mol total phosphorus (TP) in feedwater is necessarily required to keep the TP concentration under 50μg/L in UF permeate. © 2012 Elsevier B.V.

  10. Quality assurance and quality control for Hydro-Quebec's ambient air monitoring networks

    International Nuclear Information System (INIS)

    Lambert, M.; Varfalvy, L.

    1993-01-01

    Hydro Quebec has three ambient air monitoring networks to determine the contribution of some of its thermal plants to ambient air quality. They are located in Becancour (gas turbines), Iles-de-la-Madeleine (diesel), and Tracy (conventional oil-fired). To ensure good quality results and consistency between networks, a quality assurance/quality control program was set up. A description is presented of the ambient air quality monitoring network and the quality assurance/quality control program. A guide has been created for use by the network operators, discussing objectives of the individual network, a complete description of each network, field operation for each model of instrument in use, treatment of data for each data logger in use, global considerations regarding quality assurance and control, and reports. A brief overview is presented of the guide's purpose and contents, focusing on the field operation section and the sulfur dioxide and nitrogen oxide monitors. 6 figs., 1 tab

  11. Quality control of mammography departments in Slovakia

    International Nuclear Information System (INIS)

    Horvathova, M.; Nikodemova, D.

    2007-01-01

    Complete test of publication follows. Considering the fact that mammary gland is the most sensitive organ to ionizing radiation, the Commission of the Ministry of Health of SR for QA in radiology organized a pilot two-run country wide audit conducted in 42 mammography departments that have met the beforehand criteria. During the audit the methods for establishing the individual parameters in technical and clinical part of quality assurance in mammography were elaborated and implemented. Technical and clinical parameters of the imaging process that mostly affect the quality of diagnostic information were followed up. These parameters included: the object thickness compensation, optical density deviation, evaluation of the film quality by means of special phantom, etc. Important measurement of ESDs at participating departments enabled to compare the radiation load of mammography patients in Slovakia with reference values in European guidelines. The uniform standard method for QA at mammography departments was elaborated and published as the regulation of the Ministry of Health for performance of preventive mammography examinations in SR. The presented results show the improved quality of mammography examinations due to regular check-ups of technical and clinical parameters and fulfilment of the required values in all parameters. The audit results are the basis for continuous quality assessment of mammography departments as a main prerequisite for conducting preventive examinations and for health insurance purposes.

  12. [On-site quality control of acupuncture randomized controlled trial: design of content and checklist of quality control based on PICOST].

    Science.gov (United States)

    Li, Hong-Jiao; He, Li-Yun; Liu, Zhi-Shun; Sun, Ya-Nan; Yan, Shi-Yan; Liu, Jia; Zhao, Ye; Liu, Bao-Yan

    2014-02-01

    To effectively guarantee quality of randomized controlld trial (RCT) of acupuncture and develop reasonable content and checklist of on-site quality control, influencing factors on quality of acupuncture RCT are analyzed and scientificity of quality control content and feasibility of on-site manipulation are put into overall consideration. Based on content and checklist of on-site quality control in National 11th Five-Year Plan Project Optimization of Comprehensive Treatment Plan for TCM in Prevention and Treatment of Serious Disease and Clinical Assessment on Generic Technology and Quality Control Research, it is proposed that on-site quality control of acupuncture RCT should be conducted with PICOST (patient, intervention, comparison, out come, site and time) as core, especially on quality control of interveners' skills and outcome assessment of blinding, and checklist of on-site quality control is developed to provide references for undertaking groups of the project.

  13. Quality control protocols for radiodiagnosis agents and radiopharmaceuticals

    International Nuclear Information System (INIS)

    Robles, A.; Condor, M.; Caballero, J.; Morote, M.; Garcia, C.; Benites, M.

    1997-01-01

    Based on the compilation of pharmacopoeia methods, literature, manuals and other information developed in our laboratory, protocols have been prepared to carry out quality controls for radiodiagnosis agents (RDA), better known as kits and RDA labelled with Tc99m. Quality control protocols cover physicochemical and biological controls. Physicochemical controls described for RDA include physical characteristics, particle size and number, pH, chemical identification, humidity, tin II; whereas biological controls include sterility, acute toxicity and bacterial endotoxin determination (LAL). Physicochemical controls described for radiopharmaceuticals labelled with Tc99m are pH and radiochemical purity; while biological distribution is described as a biological control

  14. Intergrated approach to quality control procedures of radioisotopes and radiopharmaceuticals

    International Nuclear Information System (INIS)

    Rohani Mohamad

    1986-01-01

    Various aspects of the quality control procedures for radioisotopes and radiopharmaceuticals have been discussed. The paper high lighted those procedures that are important in ensuring the efficacy of the product. It also gives a general idea of the various procedures that are actually carried out by the Quality Control Section. (A.J.)

  15. Electronic quality control on dental x-rays equipment

    International Nuclear Information System (INIS)

    Pomares C, Martin

    1996-09-01

    A brief description of dental x-ray equipment is done. The non-invasive quality control is treated as than the responsibilities from the dentists to the patient and the equipment. A propose for quality control for dental x-ray equipment, film and developer is include

  16. Status and future trends of Analytical Quality Control Services

    International Nuclear Information System (INIS)

    LaBrecque, J.J.; Schelenz, R.; Hardy, E.P.

    1987-07-01

    This report reviews the present Analytical Quality Control Services (AQCS) programme components in the light of the needs of IAEA Member States for analytical reference materials and intercomparisons, provides guidelines for the direction which the programme should take in the future and identifies the type of Analytical Quality Control Services most urgently required by the Member States

  17. Safety of timber : An analysis of quality control options

    NARCIS (Netherlands)

    Kovryga, A.; Stapel, P.; Van de Kuilen, J.W.G.

    2014-01-01

    The quality assurance of timber properties is important for the safety of timber structures. In the current study, the quality control options of timber are analysed under the prism of the different growth regions. Therefore, these options - machine and output control - are simulated in accordance

  18. Chemical and physical quality control of the HIPPURAN-131I

    International Nuclear Information System (INIS)

    Morin Zorilla, J.; Olive, E.; Isaac, M.; Cruz, J.

    1989-01-01

    Some physico-chemical methods for analytical control of Hippuran- 131 I are compared. The most convenient to applicate in hospitals and in more specialized quality control laboratories are recommended. The quality of Hippuran- 131 I produced by ISOTOP (USSR) is also evaluated. The product met the requirement of the International Pharmacopeia

  19. Internal quality control in serological tests for syphilis.

    OpenAIRE

    Wasley, G D

    1985-01-01

    The importance of syphilis serological tests demands that laboratory reports are reliable. Internal quality control applied to the organisation of a syphilis serology service improves laboratory bench performance and reporting. Described here are internal quality control procedures of a department that serves a genitourinary medicine clinic and conducts 70 000 tests a year to investigate for syphilis.

  20. Application of improved quality control technology to pressure vessels

    International Nuclear Information System (INIS)

    Kriedt, F.

    1985-01-01

    Within the last decade, ASME Boiler and Pressure Vessel Code Section VIII-1 instituted requirements for a formal written quality control system. The results, good and bad, of this requirement are discussed. The effects are far reaching from a national economic standpoint. Quality control technology has improved. These improvements are discussed and compared to existing requirements of the CODE. Recommended improvements are suggested

  1. Quality control of geological voxel models using experts' gaze

    NARCIS (Netherlands)

    Maanen, P.P. van; Busschers, F.S.; Brouwer, A.M.; Meulen, M.J. van der; Erp, J.B.F. van

    2015-01-01

    Due to an expected increase in geological voxel model data-flow and user demands, the development of improved quality control for such models is crucial. This study explores the potential of a new type of quality control that improves the detection of errors by just using gaze behavior of 12

  2. Quality Control of Geological Voxel Models using Experts' Gaze

    NARCIS (Netherlands)

    van Maanen, Peter-Paul; Busschers, Freek S.; Brouwer, Anne-Marie; van der Meulendijk, Michiel J.; van Erp, Johannes Bernardus Fransiscus

    Due to an expected increase in geological voxel model data-flow and user demands, the development of improved quality control for such models is crucial. This study explores the potential of a new type of quality control that improves the detection of errors by just using gaze behavior of 12

  3. Quality control of nuclear fuels - technical and economic aspects

    International Nuclear Information System (INIS)

    Strasser, A.A.

    1982-01-01

    The qualification and resolution of questions relating to the cost benefit of quality control are based on the interaction of a broad range of technologies and economics. This paper discusses examples of current areas of interest in quality control, and their relationship to the fuel cycle costs. (orig.)

  4. Design an Indoor Air Quality Controller Based on LPC2478

    Directory of Open Access Journals (Sweden)

    Shi Shuheng

    2014-07-01

    Full Text Available Indoor air quality is very important to our lives, because we spend most of our time indoor. In order to improve the air quality of indoor, this paper designs an indoor environment quality monitoring and controlling system based on ARM microcontroller LPC2478. It will do a real-time monitoring work for detecting the indoor environmental factors and comprehensively evaluate its air quality level. While the indoor air quality status is "poor", this intelligent system will automatically start the heat exchange ventilator for indoor environmental quality improvement. The results compared to traditional natural ventilation method show the better performance of proposed system.

  5. Dose calibrator user and quality control guide

    International Nuclear Information System (INIS)

    Blanchis, Philippe; Amiot, Marie-Noelle; Moune, Muriel; Bellanger, Anne-Christine; Chauvenet, Bruno; Verdeau, Eric; Gardin, Isabelle; Martineau, Antoine; Ricard, Marcel; Caselles, Olivier; Guilhem, Marie-Therese; Hapdey, Sebastien; Lisbona, Albert; Bonnot-Lours, Sophie; Dumont, Agnes; Lemercier, Valerie; Rizzo-Padoin, Nathalie

    2006-06-01

    This document is a practical guide for the use and control of dose calibrators which are instruments used for radioactivity measurements. After a recall of the calibrator operation principle, the authors describe all the operations performed on this apparatus all along its lifetime: controls to be performed for device acceptance, aspects to be addressed during installation, controls to be performed before any use, daily controls, more detailed controls, and operations to be performed for maintenance, in case of dysfunctions or for re-calibration

  6. Potential and limitations of modern equipment for real time control of urban wastewater systems

    DEFF Research Database (Denmark)

    Campisano, A.; Cabot Ple, J.; Muschalla, D.

    2013-01-01

    Real Time Control (RTC) has become an accepted technique for improving the performance of Urban Drainage Systems (UDS) due to its flexibility and sustainability. Numerous implementations of RTC have been reported during the last decades. At the same time, guideline documents and state...... describes the specific components in detail. This comprises the introduction of available technologies for sensors, actuators, controllers and telemetry systems in the context of RTC and the discussion of their potential and limitations. Lessons learned from the field operational experiences and future......-of-the-art reports have been published. Whereas the general aspects and challenges of planning and installation of RTC systems are well covered, there is a lack of information about the adequate equipment for RTC of UDS. After identifying and briefly discussing the basic components of RTC systems for UDS, this paper...

  7. Water quality, hydrology, and simulated response to changes in phosphorus loading of Mercer Lake, Iron County, Wisconsin, with special emphasis on the effects of wastewater discharges

    Science.gov (United States)

    Robertson, Dale M.; Garn, Herbert S.; Rose, William J.; Juckem, Paul F.; Reneau, Paul C.

    2012-01-01

    Mercer Lake is a relatively shallow drainage lake in north-central Wisconsin. The area near the lake has gone through many changes over the past century, including urbanization and industrial development. To try to improve the water quality of the lake, actions have been taken, such as removal of the lumber mill and diversion of all effluent from the sewage treatment plant away from the lake; however, it is uncertain how these actions have affected water quality. Mercer Lake area residents and authorities would like to continue to try to improve the water quality of the lake; however, they would like to place their efforts in the actions that will have the most beneficial effects. To provide a better understanding of the factors affecting the water quality of Mercer Lake, a detailed study of the lake and its watershed was conducted by the U.S. Geological Survey in collaboration with the Mercer Lake Association. The purposes of the study were to describe the water quality of the lake and the composition of its sediments; quantify the sources of water and phosphorus loading to the lake, including sources associated with wastewater discharges; and evaluate the effects of past and future changes in phosphorus inputs on the water quality of the lake using eutrophication models (models that simulate changes in phosphorus and algae concentrations and water clarity in the lake). Based on analyses of sediment cores and monitoring data collected from the lake, the water quality of Mercer Lake appears to have degraded as a result of the activities in its watershed over the past 100 years. The water quality appears to have improved, however, since a sewage treatment plant was constructed in 1965 and its effluent was routed away from the lake in 1995. Since 2000, when a more consistent monitoring program began, the water quality of the lake appears to have changed very little. During the two monitoring years (MY) 2008-09, the average summer near-surface concentration of total

  8. Quality control of thermoluminesce personal dose monitoring

    International Nuclear Information System (INIS)

    Shang Aiguo; He Wenchang; Zhao Fengtao

    2006-01-01

    In order to evaluate the influence factor to thermoluminesce personal dose monitoring result, the every question that can appear based on the fact was analyzed. The results show that the detector, annealing, measuring process can influence the monitoring result. It gives some measures to enhance monitoring quality. (authors)

  9. Quality Control Specialist | Center for Cancer Research

    Science.gov (United States)

    Within the Leidos Biomedical Research Inc.’s Clinical Research Directorate, the Clinical Monitoring Research Program (CMRP) provides high-quality comprehensive and strategic operational support to the high-profile domestic and international clinical research initiatives of the National Cancer Institute (NCI), National Institute of Allergy and Infectious Diseases (NIAID),

  10. Quality assurance in education: The role of ICT and quality control ...

    African Journals Online (AJOL)

    Quality assurance in education is perceived in this paper to be a product of the impact of information and communication technologies as well as the statutory control measures especially in tertiary institutions in Nigeria. The paper reviews the concept of quality and quality assurance and their general application to ...

  11. How to set up and manage quality control and quality assurance

    NARCIS (Netherlands)

    Visschedijk, M.; Hendriks, R.; Nuyts, K.

    2005-01-01

    This document provides a general introduction to clarify the differences between quality control (QC) and quality assurance (QA). In addition it serves as a starting point for implementing a quality system approach within an organization. The paper offers practical guidance to the implementation of

  12. Removal of bacterial cells, antibiotic resistance genes and integrase genes by on-site hospital wastewater treatment plants: surveillance of treated hospital effluent quality

    KAUST Repository

    Timraz, Kenda Hussain Hassan

    2016-12-15

    This study aims to evaluate the removal efficiency of microbial contaminants, including total cell counts, antibiotic-resistant bacteria (ARB), antibiotic resistance genes (ARGs, e.g. tetO, tetZ, sul1 and sul2) and integrase genes (e.g. intl1 and intl2), by wastewater treatment plants (WWTPs) operated on-site of two hospitals (i.e., SH WWTP and IH WWTP). Both SH and IH WWTPs utilize the conventional activated sludge process but differences in the removal efficiencies were observed. Over the 2 week sampling period, IH WWTP outperformed SH WWTP, and achieved an approximate 0.388 to 2.49-log log removal values (LRVs) for total cell counts compared to the 0.010 to 0.162-log removal in SH WWTP. Although ARB were present in the hospital influent, the treatment process of both hospitals effectively removed ARB from most of the effluent samples. In instances where ARB were recovered in the effluent, none of the viable isolates were identified to be opportunistic pathogenic species based on 16S rRNA gene sequencing. However, sul1 and intl1 genes remained detectable at up to 105 copies per mL or 8 x 10(-1) copies per 16S rRNA gene in the treated effluent, with an LRV of less than 1.2. When the treated effluent is discharged from hospital WWTPs into the public sewer for further treatment as per requirement in many countries, the detected amount of ARGs and integrase genes in the hospital effluent can become a potential source of horizontal gene dissemination in the municipal WWTP. Proper on-site wastewater treatment and surveillance of the effluent quality for emerging contaminants are therefore highly recommended.

  13. Impact-based integrated real-time control for improvement of the Dommel River water quality

    NARCIS (Netherlands)

    Langeveld, J.; Benedetti, L.; Klein, de J.J.M.; Nopens, I.; Amerlinck, Y.; Nieuwenhuijzen, van A.F.; Flameling, T.; Zanten, van O.; Weijers, S.

    2013-01-01

    The KALLISTO project aims at finding cost-efficient sets of measures to meet the Water Framework Directive (WFD) derived goals for the river Dommel. Within the project, both acute and long term impacts of the urban wastewater system on the chemical and ecological quality of the river are studied

  14. Proposed quality control protocol of a dual energy bone densitometer from Spanish protocol for quality control of radiology

    International Nuclear Information System (INIS)

    Saez, F.; Benito, M. A.; Collado, P.; Saez, M.

    2011-01-01

    In this paper we propose additional testing to complete the tests by the Spanish Protocol for Quality Control of Diagnostic Radiology, taking into account the particular characteristics of these units, and including these tests in the estimation of patient dose dose assessment area. There is also the possibility to independently verify the quality control tests that are done automatically.

  15. Quality Management of CERN Vacuum Controls

    CERN Document Server

    Antoniotti, F; Fortescue-Beck, E; Gama, J; Gomes, P; Le Roux, P; Pereira, H F; Pigny, G

    2014-01-01

    The vacuum controls Section (TE-VSC-ICM) is in charge of the monitoring, maintenance and consolidation of the control systems of all accelerators and detectors in CERN; this represents 6 000 instruments distributed along 128 km of vacuum chambers, often of heterogeneous architectures and of diverse

  16. PROCESS VARIABILITY REDUCTION THROUGH STATISTICAL PROCESS CONTROL FOR QUALITY IMPROVEMENT

    Directory of Open Access Journals (Sweden)

    B.P. Mahesh

    2010-09-01

    Full Text Available Quality has become one of the most important customer decision factors in the selection among the competing product and services. Consequently, understanding and improving quality is a key factor leading to business success, growth and an enhanced competitive position. Hence quality improvement program should be an integral part of the overall business strategy. According to TQM, the effective way to improve the Quality of the product or service is to improve the process used to build the product. Hence, TQM focuses on process, rather than results as the results are driven by the processes. Many techniques are available for quality improvement. Statistical Process Control (SPC is one such TQM technique which is widely accepted for analyzing quality problems and improving the performance of the production process. This article illustrates the step by step procedure adopted at a soap manufacturing company to improve the Quality by reducing process variability using Statistical Process Control.

  17. Alpine infrastructure in Central Europe: integral evaluation of wastewater treatment systems at mountain refuges.

    Science.gov (United States)

    Weissenbacher, N; Mayr, E; Niederberger, T; Aschauer, C; Lebersorger, S; Steinbacher, G; Haberl, R

    2008-01-01

    Planning, construction and operation of onsite wastewater treatment systems at mountain refuges is a challenge. Energy supply, costly transport, limited water resources, unfavourable climate and load variations are only some of the problems that have to be faced. Additionally, legal regulations are different between and even within countries of the Alps. To ensure sustainability, integrated management of the alpine infrastructure management is needed. The energy and water supply and the wastewater and waste disposal systems and the cross-relations between them were analysed for 100 mountain refuges. Wastewater treatment is a main part of the overall 'mountain refuge' system. The data survey and first analyses showed the complex interaction of the wastewater treatment with the other infrastructure. Main criteria for reliable and efficient operation are training, technical support, user friendly control and a relatively simple system set up. Wastewater temperature, alkalinity consumption and high peak loads have to be considered in the planning process. The availability of power in terms of duration and connexion is decisive for the choice of the system. Further, frequency fluctuations may lead to damages to the installed aerators. The type of water source and the type of sanitary equipment influence the wastewater quantity and quality. Biosolids are treated and disposed separately or together with primary or secondary sludge from wastewater treatment dependent on the legal requirements. IWA Publishing 2008.

  18. Water quality control device and water quality control method for reactor primary coolant system

    International Nuclear Information System (INIS)

    Wada, Yoichi; Ibe, Eishi; Watanabe, Atsushi.

    1995-01-01

    The present invention is suitable for preventing defects due to corrosion of structural materials in a primary coolant system of a BWR type reactor. Namely, a concentration measuring means measures the concentration of oxidative ingredients contained in a reactor water. A reducing electrode is disposed along a reactor water flow channel in the primary coolant system and reduces the oxidative ingredients. A reducing counter electrode is disposed along the reactor water flow channel in the primary coolant system, and electrically connected to the reducing electrode. The reactor structural materials are used as a reference electrode providing a reference potential to the reducing electrode and the reducing counter electrode. A potential control means controls the potential of the reducing electrode relative to the reference potential based on the signals from the concentration measuring means. A stable reference potential in a region where an effective oxygen concentration is stable can be obtained irrespective of the change of operation conditions by using the reactor structural materials disposed to a boiling region in the reactor core as a reference electrode. As a result, the water quality can be controlled at high accuracy. (I.S.)

  19. Options for wastewater management in Harare, Zimbabwe

    NARCIS (Netherlands)

    Nhapi, I.

    2004-01-01

    The sustainable management of wastewater should aim at pollution prevention and reduction first, followed by resource recovery and reuse. This thesis shows that substantial water quality improvements could be achieved through a so-called 3-Step Strategic Approach to wastewater management. This

  20. NIF Projects Controls and Information Systems Software Quality Assurance Plan

    Energy Technology Data Exchange (ETDEWEB)

    Fishler, B

    2011-03-18

    Quality achievement for the National Ignition Facility (NIF) and the National Ignition Campaign (NIC) is the responsibility of the NIF Projects line organization as described in the NIF and Photon Science Directorate Quality Assurance Plan (NIF QA Plan). This Software Quality Assurance Plan (SQAP) is subordinate to the NIF QA Plan and establishes quality assurance (QA) activities for the software subsystems within Controls and Information Systems (CIS). This SQAP implements an activity level software quality assurance plan for NIF Projects as required by the LLNL Institutional Software Quality Assurance Program (ISQAP). Planned QA activities help achieve, assess, and maintain appropriate quality of software developed and/or acquired for control systems, shot data systems, laser performance modeling systems, business applications, industrial control and safety systems, and information technology systems. The objective of this SQAP is to ensure that appropriate controls are developed and implemented for management planning, work execution, and quality assessment of the CIS organization's software activities. The CIS line organization places special QA emphasis on rigorous configuration control, change management, testing, and issue tracking to help achieve its quality goals.

  1. NIF Projects Controls and Information Systems Software Quality Assurance Plan

    International Nuclear Information System (INIS)

    Fishler, B.

    2011-01-01

    Quality achievement for the National Ignition Facility (NIF) and the National Ignition Campaign (NIC) is the responsibility of the NIF Projects line organization as described in the NIF and Photon Science Directorate Quality Assurance Plan (NIF QA Plan). This Software Quality Assurance Plan (SQAP) is subordinate to the NIF QA Plan and establishes quality assurance (QA) activities for the software subsystems within Controls and Information Systems (CIS). This SQAP implements an activity level software quality assurance plan for NIF Projects as required by the LLNL Institutional Software Quality Assurance Program (ISQAP). Planned QA activities help achieve, assess, and maintain appropriate quality of software developed and/or acquired for control systems, shot data systems, laser performance modeling systems, business applications, industrial control and safety systems, and information technology systems. The objective of this SQAP is to ensure that appropriate controls are developed and implemented for management planning, work execution, and quality assessment of the CIS organization's software activities. The CIS line organization places special QA emphasis on rigorous configuration control, change management, testing, and issue tracking to help achieve its quality goals.

  2. A phantom for quality control in mammography

    International Nuclear Information System (INIS)

    Gambaccini, M.; Rimondi, O.; Marziani, M.; Toti, A.

    1989-01-01

    A phantom for evaluating image quality in mammography has been designed and will be used in the Italian national programme ''Dose and Quality in Mammography''. The characteristics of the phantom are (a) about the same X-ray transmission as a 5 cm 50% fat and 50% water breast for energies between 15 and 50 keV and (b) optimum energies for imaging of the test objects (included in the phantom) in very close agreement with the optimum energies for imaging of calcifications and tumours in a 5 cm 50% fat and 50% water breast. An experimental comparison between the prototype and some commercial phantoms was carried out. Measurements are in progress to test the phantom's ability to evaluate the performances of mammographic systems quantitatively. (author)

  3. Justification and quality control in radiodiagnostics

    International Nuclear Information System (INIS)

    Dalen, A. van

    1989-01-01

    The role of the radiodiagnostician in justification of x-ray examination is discussed. Under the final responsibility of the radio-diagnostician the more common examinations are performed by laboratory assistants. A justification judgement before by the radio-diagnostician does not take place. In case of complicated examinations often previous consultation between radio-diagnostician and clinician is necessary. The fast development of new techniques like CT, echography and MRI has as result that the modern radio-diagnostician develops more and more into a imaging-specialist. In the consultation with the clinician he advises about the optimal diagnostics for a certain patient, taking optimally into account the risks of x-radiation. The justifying role of the radio-diagnostician depends further upon the relation with the requiring physician. In general the inter-collegial consultation is assumed to be sufficient within the hospitals, however the feedback to general practitioners seems to be improvable in some cases. With regard to quality assurance it is remarked that the quality of the examination may not be endangered by a too strong emphasis upon radiation reduction. Aspects like education level, protocol learning, dose limits, degressive tariffs, information-transfer, radiation passport, analysis between 'blue' ton, centralization of x-ray examination and quality of apparatus, are discussed. From the Government primarily a constraint setting policy is expected, in which rule-giving with respect to quality of education and apparatus is highly important. A stimulation of inter-collegial consulting may be expected, in particular in financial sense. A permission policy has to be managed, which ensures centralization of apparatus and centrally performance of x-ray examination as much as possible. Finally warning is given for the effects of excessive fear for radiation which causes refraining of medical necessary examination. The various risk have to be weighed up

  4. Some observations about quality control tests of Spect

    International Nuclear Information System (INIS)

    Robilotta, C.C.; Rebelo, M.F.S.; Oliveira, M.A.

    1987-01-01

    Some observations about quality control tests done in the tomographic system of Heart Institute are described. Among the tests, the traditional test of quality control with scintillation camera and the specific test for tomography systems are induced. The traditional tests are essential, but not sufficient for evaluating the Spect equipment and the specific tests have been effectuated in controlled conditions. (C.G.C.) [pt

  5. Effect of quality control implementation on image quality of radiographic films and irradiation doses to patients

    International Nuclear Information System (INIS)

    Cheng Yuxi; Zhou Qipu; Ge Lijuan; Hou Changsong; Qi Xuesong; Yue Baorong; Wang Zuoling; Wei Kedao

    1999-01-01

    Objective: To study the changes in the image quality of radiographic films and the irradiation doses to patients after quality control (QC) implementation. Methods: The entrance surface doses (ESD) to patients measured with TLD and the image quality of radiographic films were evaluated on the basis of CEC image quality criteria. Results: The ESD to patients were significantly reduced after QC implementation (P 0.05), but the post-QC image quality was significantly improved in chest PA, lumbar spine AP and pelvis AP(P0.01 or P<0.05). Conclusion: Significantly reduced irradiation dose with improved image quality can be obtained by QC implementation

  6. Management Model for efficient quality control in new buildings

    Directory of Open Access Journals (Sweden)

    C. E. Rodríguez-Jiménez

    2017-09-01

    Full Text Available The management of the quality control of each building process is usually set up in Spain from different levels of demand. This work tries to obtain a model of reference, to compare the quality control of the building process of a specific product (building, and to be able to evaluate its warranty level. In the quest of this purpose, we take credit of specialized sources and 153 real cases of Quality Control were carefully revised using a multi-judgment method. Applying different techniques to get a specific valuation (impartial of the input parameters through Delphi’s method (17 experts query, whose matrix treatment with the Fuzzy-QFD tool condenses numerical references through a weighted distribution of the selected functions and their corresponding conditioning factors. The model thus obtained (M153 is useful in order to have a quality control reference to meet the expectations of the quality.

  7. Profiles of illicit drug use during annual key holiday and control periods in Australia: wastewater analysis in an urban, a semi-rural and a vacation area.

    Science.gov (United States)

    Lai, Foon Yin; Bruno, Raimondo; Hall, Wayne; Gartner, Coral; Ort, Christoph; Kirkbride, Paul; Prichard, Jeremy; Thai, Phong K; Carter, Steve; Mueller, Jochen F

    2013-03-01

    To examine changes in illicit drug consumption between peak holiday season (23 December-3 January) in Australia and a control period two months later in a coastal urban area, an inland semi-rural area and an island populated predominantly by vacationers during holidays. Analysis of representative daily composite wastewater samples collected from the inlet of the major wastewater treatment plant in each area. Three wastewater treatment plants. Wastewater treatment plants serviced approximately 350, 000 persons in the urban area, 120,000 in the semi-rural area and 1100-2400 on the island. Drug residues were analysed using liquid chromatography coupled to a tandem mass spectrometer. Per capita drug consumption was estimated. Changes in drug use were quantified using Hedges' g. During the holidays, cannabis consumption in the semi-rural area declined (g = -2.8) as did methamphetamine (-0.8), whereas cocaine (+1.5) and ecstasy (+1.6) use increased. In the urban area, consumption of all drugs increased during holidays (cannabis +1.6, cocaine +1.2, ecstasy +0.8 and methamphetamine +0.3). In the vacation area, methamphetamine (+0.7), ecstasy (+0.7) and cocaine (+1.1) use increased, but cannabis (-0.5) use decreased during holiday periods. While the peak holiday season in Australia is perceived as a period of increased drug use, this is not uniform across all drugs and areas. Substantial declines in drug use in the semi-rural area contrasted with substantial increases in urban and vacation areas. Per capita drug consumption in the vacation area was equivalent to that in the urban area, implying that these locations merit particular attention for drug use monitoring and harm minimisation measures. © 2012 The Authors, Addiction © 2012 Society for the Study of Addiction.

  8. [Evaluation of the quality control system in blood transfusion service].

    Science.gov (United States)

    Jovanović, R

    2000-01-01

    Implementation of quality system improvement at the Blood Transfusion Institute Novi Sad, included adjustments in practice to the request of ISO 9001 standard. Quality improvement must be a permanent activity of the Institute. The audit is a management tool for monitoring the quality assurance system and is either a quality audit or a medical audit. A well planned, comprehensive quality audit covers each activity of the Blood Transfusion Institute. The procedures may be internal or external. Quality manager is responsible for annual internal quality audits. The purpose of internal audits is to check the efficiency of the quality system in terms of realization of quality policy, fulfullment of designed targets and implementation of quality system documents. An internal quality audit is performed in accordance with the procedure and audit findings are reported to the management in a form of internal quality report as a part of quality system review. The findings must be communicated to all persons responsible for the controlled area. Quality manager can initiate an internal quality audit whenever it is realized that problems about the quality system have occurred. Audits are conducted by the quality manager or an audit team. The accurate list of internal auditors is kept in the Institute archive. Medical audit carried out by a transfusion committee, evaluates the quality of blood transfusion for determining the degree of compliance with established local or national guidelines, in order to promote optimal transfusion practice. Audits are not only used for determining further quality management activities, but also make basis for creating and maintenance of excellent relations with product and service users. Considering all this, Blood Transfusion Institute exceeds the requirements of ISO 9000 standards series.

  9. Spatial control of groundwater contamination, using principal

    Indian Academy of Sciences (India)

    Spatial control of groundwater contamination, using principal component analysis ... anthropogenic (agricultural activities and domestic wastewaters), and marine ... The PC scores reflect the change of groundwater quality of geogenic origin ...

  10. Treatment of highly concentrated tannery wastewater using electrocoagulation: Influence of the quality of aluminium used for the electrode.

    Science.gov (United States)

    Elabbas, S; Ouazzani, N; Mandi, L; Berrekhis, F; Perdicakis, M; Pontvianne, S; Pons, M-N; Lapicque, F; Leclerc, J-P

    2016-12-05

    This paper deals with the ability of electrocoagulation (EC) to remove simultaneously COD and chromium from a real chrome tanning wastewater in a batch stirred electro-coagulation cell provided with two aluminium-based electrodes (aluminium/copper/magnesium alloy and pure aluminium). Effects of operating time, current density and initial concentration of Cr(III) and COD have been investigated. The concentrations of pollutants have been successfully reduced to environmentally acceptable levels even if the concentrated effluent requires a long time of treatment of around 6h with a 400A/m(2) current density. The aluminium alloy was found to be more efficient than pure aluminium for removal of COD and chromium. Dilution of the waste has been tested for treatment: high abatement levels could be obtained with shorter time of treatment and lower current densities. Energy consumption of the electrocoagulation process was also discussed. The dilution by half of the concentrated waste leads to a higher abatement performance of both COD and chromium with the best energy efficiency. Copyright © 2016 Elsevier B.V. All rights reserved.

  11. Fuel element radiometry system for quality control

    International Nuclear Information System (INIS)

    Bhattacharya, Sadhana; Gaur, Swati; Sridhar, Padmini; Mukhopadhyay, P.K.; Vaidya, P.R.; Das, Sanjoy; Sinha, A.K.; Bhatt, Sameer

    2010-01-01

    An indigenous and fully automatic PC based radiometry system has been designed and developed. The system required a vibration free scanning with various automated sequential movements to scan the fuel pin of size 5.8 mm (OD) x 1055 mm (L) along its full length. A mechanical system with these requirements and precision controls has been designed. The system consists of a tightly coupled and collimated radiation source-detector unit and data acquisition and control system. It supports PLC based control electronics to control and monitor the movement of fuel element, nuclear data acquisition and analysis system and feedback system to the mechanical scanner to physically accept or reject the fuel pin based on the decision derived by the software algorithms. (author)

  12. Quality control of radioactive waste products

    International Nuclear Information System (INIS)

    Martens, B.R.; Warnecke, E.; Odoj, R.

    1986-01-01

    The variety of incoming untreated wastes, treatment methods, waste forms and containers requires a great variety of controlling methods and principles to be applied both during waste treatment and on the final product. The paper describes product control schemes and methods, sampling systems and transportable testing equipment for waste drums, and equipment for waste cementation using in-drum stirring and subsequent fixation of solid wastes in the flowable product. (DG) [de

  13. Dosimetry and quality control in radiodiagnosis

    International Nuclear Information System (INIS)

    Le Gouic, M.

    1983-07-01

    This work deals with physics of radiodiagnosis. In a first part a study of the characteristics of different kinds of radiological equipments and a quality assurance of some of them (standard radiography, coronarography and computed tomography) have been performed. The second part deals with patient irradiation. After a bibliographic study of radiodiagnosis dosimetry, two kinds of dosimetric measures have been made: ''in vitro'' measures, using a phantom, that had allowed to calibrate the equipment and to improve the individual irradiation card, and ''in vivo'' measures. For the first types of measures ionization chambers, have been used for the second thermoluminescent dosimeters [fr

  14. Internal control reporting and accounting quality : Insight "comply-or-explain" internal control regime

    OpenAIRE

    Cao Thi Thanh, Huyen; Cheung, Tina

    2010-01-01

    Nowadays, there exist two reporting regimes, rules-based and principle-based (comply-or-explain). In the rules-based environment, researchers have studied the relationship between internal control quality and accounting quality. Prior studies have suggested that reports on internal control are an effective way for investors to evaluate the quality of the firm‟s internal control. By having a sound system of internal control, it creates reliance upon the firm‟s financial reporting. Therefore, t...

  15. Internal quality control of PCR-based genotyping methods

    DEFF Research Database (Denmark)

    Bladbjerg, Else-Marie; Gram, Jørgen; Jespersen, Jørgen

    2002-01-01

    Internal quality control programmes for genetic analyses are needed. We have focused on quality control aspects of selected polymorphism analyses used in thrombosis research. DNA was isolated from EDTA-blood (n = 500) and analysed for 18 polymorphisms by polymerase chain reaction (PCR), i...... because of positive reagent blanks (controls (Control of data handling revealed 0.1% reading mistakes and 0.5% entry mistakes. Based on our experiences, we propose an internal quality control programme......, electrophoresis (analytical factors), result reading and entry into a database (post-analytical factors). Furthermore, we evaluated a procedure for result confirmation. Isolated DNA was of good quality (42 micrograms/ml blood, A260/A280 ratio > 1.75, negative DNAsis tests). Occasionally, results were reanalysed...

  16. Odor control in evaporation ponds treating olive mill wastewater through the use of Ca(OH)2.

    Science.gov (United States)

    Lagoudianaki, E; Manios, T; Geniatakis, M; Frantzeskaki, N; Manios, V

    2003-01-01

    Different amounts of Ca(OH)2 were added in 2 L beakers containing 1 L of olive mill wastewater (OMW). The mixture was stirred for 45 min and left to settle. Wastewater analysis was used in order to determine the effect of the different amounts of calcium hydroxide in the treating process, three days after the application. The Odor Detection Threshold was used for determining the effect of the treatment in the odors produced in the beakers, three and 30 days after. Both sets of measurements indicated an important reduction in wastewater pollutants and odor emission when 10 g/L of Ca(OH)2 were added. In order to evaluate these results in more realistic conditions. 10 L plastic containers were filled with 6 L of OMW, relevant amounts of Ca(OH)2 were added, the mixture was stirred manually and left to settle in the open. Again, 10 g/L of calcium hydroxide produced the best results in odor reduction and wastewater treatment.

  17. Quality control of CANDU6 fuel element in fabrication process

    International Nuclear Information System (INIS)

    Li Yinxie; Zhang Jie

    2012-01-01

    To enhance the fine control over all aspects of the production process, improve product quality, fuel element fabrication process for CANDU6 quality process control activities carried out by professional technical and management technology combined mode, the quality of the fuel elements formed around CANDU6 weak links - - end plug , and brazing processes and procedures associated with this aspect of strict control, in improving staff quality consciousness, strengthening equipment maintenance, improved tooling, fixtures, optimization process test, strengthen supervision, fine inspection operations, timely delivery carry out aspects of the quality of information and concerns the production environment, etc., to find the problem from the improvement of product quality and factors affecting the source, and resolved to form the active control, comprehensive and systematic analysis of the problem of the quality management concepts, effectively reducing the end plug weld microstructure after the failure times and number of defects zirconium alloys brazed, improved product quality, and created economic benefits expressly provided, while staff quality consciousness and attention to detail, collaboration department, communication has been greatly improved and achieved very good management effectiveness. (authors)

  18. APPLICATION OF HIDDEN MARKOV CHAINS IN QUALITY CONTROL

    Directory of Open Access Journals (Sweden)

    Hanife DEMIRALP

    2013-01-01

    Full Text Available The ever growing technological innovations and sophistication in industrial processes require adequate checks on quality. Thus, there is an increasing demand for simple and efficient quality control methods. In this regard the control charts stand out in simplicity and efficiency. In this paper, we propose a method of controlling quality based on the theory of hidden Markov chains. Based on samples drawn at different times from the production process, the method obtains the state of the process probabilistically. The main advantage of the method is that it requires no assumption on the normality of the process output.

  19. Implementation of quality control systematics for personnel monitoring services

    International Nuclear Information System (INIS)

    Franco, J.O.A.

    1984-01-01

    The implementation of statistical quality control techniques used in industrial practise is proposed to dosimetric services. 'Control charts' and 'sampling inspection' are adapted respectively for control of measuring process and of dose results produced in routine. A chapter on Radiation Protection and Personnel Monitoring was included. (M.A.C.) [pt

  20. Web quality control for lectures: Supercourse and Amazon.com.

    Science.gov (United States)

    Linkov, Faina; LaPorte, Ronald; Lovalekar, Mita; Dodani, Sunita

    2005-12-01

    Peer review has been at the corner stone of quality control of the biomedical journals in the past 300 years. With the emergency of the Internet, new models of quality control and peer review are emerging. However, such models are poorly investigated. We would argue that the popular system of quality control used in Amazon.com offers a way to ensure continuous quality improvement in the area of research communications on the Internet. Such system is providing an interesting alternative to the traditional peer review approaches used in the biomedical journals and challenges the traditional paradigms of scientific publishing. This idea is being explored in the context of Supercourse, a library of 2,350 prevention lectures, shared for free by faculty members from over 150 countries. Supercourse is successfully utilizing quality control approaches that are similar to Amazon.com model. Clearly, the existing approaches and emerging alternatives for quality control in scientific communications needs to be assessed scientifically. Rapid explosion of internet technologies could be leveraged to produce better, more cost effective systems for quality control in the biomedical publications and across all sciences.