  1. Wash water waste pretreatment system

    Science.gov (United States)

    1977-01-01

    Investigations were completed on wash waters based on each candidate personal cleansing agent. Evaluations of coagulants, antifoam agents, and the effect of promising antifoams on the chemical precipitation were included. Based on these evaluations two candidate soaps as well as their companion antifoam agents were selected for further work. Operating parameters included the effect of soap concentration, ferric chloride concentration, duration of mixing, and pore size of depth filters on the degree of soap removal. The effect of pressure on water flow through filter cartridges and on the rate of decline of water flow was also investigated. The culmination of the program was the recommendation of a pretreatment concept based on chemical precipitation followed by pressure filtration.

  2. Wash water waste pretreatment system study

    Science.gov (United States)

    1976-01-01

    The use of real wash water had no adverse effect on soap removal when an Olive Leaf soap based system was used; 96 percent of the soap was removed using ferric chloride. Numerous chemical agents were evaluated as antifoams for synthetic wash water. Wash water surfactants used included Olive Leaf Soap, Ivory Soap, Neutrogena and Neutrogena Rain Bath Gel, Alipal CO-436, Aerosol 18, Miranol JEM, Palmeto, and Aerosol MA-80. For each type of soapy wash water evaluated, at least one antifoam capable of causing nonpersistent foam was identified. In general, the silicones and the heavy metal ions (i.e., ferric, aluminum, etc.) were the most effective antifoams. Required dosage was in the range of 50 to 200 ppm.

  3. Design of full scale debris washing system

    International Nuclear Information System (INIS)

    Taylor, M.L.; Dosani, M.A.; Wentz, J.A.; Patkar, A.N.; Barkley, N.P.

    1992-01-01

    Since 1987, IT Environmental Programs Inc. (ITEP, a subsidiary of International Technology Corporation) in conjunction with EPA/RREL in Cincinnati, Ohio, have been developing and conducting bench scale and pilot scale testing of a transportable debris washing system which can be used on-site for the decontamination of debris. During the initial phase of the debris decontamination project, a series of bench scale tests were performed in the laboratory to assess the ability of the system to remove contaminants from debris and to facilitate selection of the most efficient surfactant solution. Five nonionic, non-toxic, low foaming, surfactant solution (BG-5, MC-2000, LF-330, BB-100, and L-433) were selected for an experimental evaluation to determine their capacity to solubilize and remove contaminants from the surfaces of corroded steel places. The pieces of corroded steel were coated with a heavy grease mixture prepared in the laboratory and these pieces of debris were placed in a bench scale spray tank on a metal tray and subjected in a high-pressure spray for each surfactant solution for 15 minutes. At the end of the spray cycle, The tray was transferred to a second bench scale system, a high-turbulence wash tank, where the debris was washed for 30 minutes with the same surfactant solution as the used in the spray tank. After the was cycle was completed, the tray was removed from the wash tank and the debris was allowed to air-dry. Before and after treatment, surface-wipe samples were obtained from each of the six pieces of debris and were analyzed for oil and graese. Based on the results, BG-5 was selected as the solution best suited for cleaning grease-laden, metallic debris. 2 refs

  4. Genesis Eco Systems, Inc. soil washing process

    International Nuclear Information System (INIS)

    Cena, R.J.

    1994-01-01

    The Genesis soil washing system is an integrated system of modular design allowing for maximum material handling capabilities, with optimized use of space for site mobility. The Surfactant Activated Bio-enhanced Remediation Equipment-Generation 1 (SABRE-1, Patent Applied For) modification was developed specifically for removing petroleum byproducts from contaminated soils. Scientifically formulated surfactants, introduced by high pressure spray nozzles, displace the contaminant from the surface of the soil particles into the process solution. Once the contaminant is dispersed into the liquid fraction of the process, it is either mechanically removed, chemically oxidized, or biologically oxidized. The contaminated process water is pumped through the Genesis Biosep (Patent Applied For) filtration system where the fines portion is flocculated, and the contaminant-rich liquid portion is combined with an activated mixture of nutrients and carefully selected bacteria to decompose the hydrocarbon fraction. The treated soil and dewatered fines are transferred to a bermed stockpile where bioremediation continues during drying. The process water is reclaimed, filtered, and recycled within the system

  5. Physical separations soil washing system cold test results

    Energy Technology Data Exchange (ETDEWEB)

    McGuire, J.P.

    1993-07-28

    This test summary describes the objectives, methodology, and results of a physical separations soil-washing system setup and shakedown test using uncontaminated soil. The test is being conducted in preparation for a treatability test to be conducted in the North Pond of the 300-FF-1 Operable Unit. It will be used to assess the feasibility of using a physical separations process to reduce the volume of contaminated soils in the 300-FF-1 Operable Unit. The test is described in DOE-RL (1993). The setup test was conducted at an uncontrolled area located approximately 3.2 km northwest of the 300-FF-1 Operable Unit. The material processed was free of contamination. The physical separation equipment to be used in the test was transferred to the US Department of Energy (DOE) by the US Environmental Protection Agency (EPA) Risk Reduction Engineering Laboratory. On May 13, 1993, soil-washing equipment was moved to the cold test location. Design assistance and recommendation for operation was provided by the EPA.

  6. Washing of Cloth Contaminated with Radionuclides Using a Detergent-free Laundry System

    Energy Technology Data Exchange (ETDEWEB)

    Yim, Sung Paal

    2005-07-01

    In this study, a new laundry system to wash clothes without using detergent (detergent-free) was applied to wash clothes contaminated with radionuclides at the RWTF of KAERI. If the clothes contaminated with radionuclides and soil decontaminated and cleaned by washing without using detergent, the problem caused by the detergent could be solved naturally. The experiment was performed in two stages. In the first stage, washability of the processed water from the detergent=free laundry system was investigated with regard to its decontamination efficiency for the radionuclides and the detergency for the soil by using the test cloth specimens. In the second stage, real working clothes contaminated with radionuclides from the RWTF were washed by using a laundry machine equipped with a detergent-free system. Decontamination and detergency of the clothes were estimated after washing and the wastewater was also analyzed for its properties.

  7. Road surface washing system for decontaminating radioactive substances. Experiment of radioactive decontamination

    International Nuclear Information System (INIS)

    Endo, Mitsuru; Endo, Mai; Kakizaki, Takao

    2015-01-01

    The Great East Japan Earthquake that occurred on March 11, 2011 resulted in the explosion of the TEPCO Fukushima 1st Nuclear Power Plant and the global dispersion of a large quantity of radioactive substances. A high radiation dose was particularly recorded in Fukushima prefecture several weeks after the accident, although the level is presently sufficiently low. However, considering that the adverse effects of low but extended exposure to radiation are yet to be negated, there is the urgent need for further decontamination. In our study, we focused on the efficient decontamination of radioactive substances in residential areas, for which we propose a high-pressure water jet system for washing road surfaces. The system differs from conventional systems of its type that were initially designed for use in the immediate environment of the nuclear reactors of the TEPCO Fukushima 1st Nuclear Power Plant. The proposed system consists of multiple washing, transporter, and server robots. The washing robots decontaminate the road surface using high-pressure water jets and are transported between washed and unwashed areas by the transporter robots. The server robots supply the water used for washing and absorb the polluted water together with ground dust. In this paper, we describe the concept of the system and present the results of decontamination experiments. Particular attention is given to the washing robot and its mechanism and control method. The results of the integration of the washing robot in an experimental system confirmed the feasibility of the proposed system. (author)

  8. The integration of innovative technologies into a physical-separation-based soil washing system

    International Nuclear Information System (INIS)

    Krstich, M.A.

    1995-01-01

    An innovative system's approach to the treatment of soils at the Fernald Environmental Management Project (FEMP) has been proposed to effectively and cost competitively treat a significant mass of soil. The use of an integrated soil treatment system to decontaminate FEMP soils is a unique application of the soil washing technology. Due to the unfavorable soil particle size distribution and the ubiquitous distribution of uranium among these particle size fractions, conventional soil washing processes commonly used on predominantly sandy soils alone may not achieve the desirable waste minimization level without the inclusion of innovative technologies. This objective of this paper is to briefly describe the physical separation and chemical extraction process commonly used in soil washing operation and to present the baseline soil washing approach used on FEMP soils. Noting the successful and not-so-successful processes within the soil washing operation at the FEMP, a proposed innovative system's approach to treating FEMP soils will be described. This system's approach will integrate a conventional soil washing operation with proposed innovative technologies

  9. Volume reduction system by soil classifying. Soil-washing system and problems to be solved

    International Nuclear Information System (INIS)

    Oshino, Yoshio

    2016-01-01

    Radioactive contamination of ground surfaces, buildings and forests in a broad area was caused by the accident at the Fukushima Daiichi Nuclear Power Plant in Japan. The national government and municipalities have still been carrying out the decontamination works for livelihood areas after five years from the accident. The government estimated that the amounts of soils and wastes removed by the decontamination works would be about 28,000,000 cubic meters maximum including 20,000,000 cubic meters maximum of soils. The removed soils will be stored in “Interim Storage Facility” then will be finally disposed outside of Fukushima prefecture within 30 years. On the other hand, shortage of the soils as materials needed for the revitalization in Fukushima prefecture is expected. Technical Advisory Council on Remediation and Waste Management, which consists of about 90 companies, started a working group to investigate solutions to these problems. The working group focused on the investigation of the possibility to recycle the soils by washing and classification to use them as the materials for civil engineering works, and to reduce the volume of the interim storage. In the first part of this report, we have evaluated the applicability of various technologies for purification and volume reduction of the removed soils, and have researched usages, required quantities and specifications of the recycled soils. In the second part, we have made trial calculations of the volume reduction effects and costs using the washing and classification system. The calculated results showed the possibilities of reducing the storage capacity of the interim storage facility, as well as the construction and the operation costs by recycling the removed soils with the washing and classification system inside the interim storage facility. At the end of this report, we proposed problems to be solved in order to adopt the washing and classification system. (author)

  10. A novel reverse-osmosis wash water recycle system for manned space stations

    Science.gov (United States)

    Ray, R. J.; Babcock, W. C.; Barss, R. P.; Andrews, T. A.; Lachapelle, E. D.

    1984-01-01

    The preliminary development of a wash water recycle system utilizing an inside-skinned hollow-fiber membrane is described. This module configuration is based on tube-side feed and is highly resistant to fouling with a minimum of pretreatment. During an ongoing research program for NASA, these modules were operated on actual wash waters with no significant fouling for a period of 40 days. Due to the tube-side-feed flow in these hollow-fiber membranes, the fibers themselves become the pressure vessels, allowing the development of extremely lightweight membrane modules. During the NASA research program, a pre-prototype membrane module capable of processing 6 gallons per day of wash water at 97 percent recovery was developed that can be dry-stored and that weighs 120 g.

  11. Remediation of a radioactively contaminated soil using a mobile soil-washing system

    International Nuclear Information System (INIS)

    Grant, D.C.; Lahoda, E.J.; Dietrich, A.J.; Weigle, D.H.; Keegan, C.P.; Sachse, J.D.

    1993-01-01

    In order to obtain free-release of a former uranium mining site in Texas, it was required that the surface soil meet specific radiological guidelines. The soil has been contaminated with uranium and radium as a result of the spillage of well-drilling material, process solutions, and ion exchange resins during mining. To meet the required guidelines, the contaminated soil had to be either removed and disposed of off-site or remediated. For economic and long-term liability reasons, remediation of the soil by soil washing was performed. The remediation of this site utilizing the Scientific Ecology Group's soil washing system is discussed in this paper

  12. Copper Recovery from Polluted Soils Using Acidic Washing and Bioelectrochemical Systems

    Directory of Open Access Journals (Sweden)

    Karin Karlfeldt Fedje

    2015-07-01

    Full Text Available Excavation followed by landfilling is the most common method for treating soils contaminated by metals. However, as this solution is not sustainable, alternative techniques are required. Chemical soil washing is one such alternative. The aim of this experimental lab-scale study is to develop a remediation and metal recovery method for Cu contaminated sites. The method is based on the washing of soil or ash (combusted soil/bark with acidic waste liquids followed by electrolytic Cu recovery by means of bioelectrochemical systems (BES. The results demonstrate that a one- or two-step acidic leaching process followed by water washing removes >80 wt. % of the Cu. Copper with 99.7–99.9 wt. % purity was recovered from the acidic leachates using BES. In all experiments, electrical power was generated during the reduction of Cu. This clearly indicates that Cu can also be recovered from dilute solutions. Additionally, the method has the potential to wash co-pollutants such as polycyclic aromatic hydrocarbons (PAHs and oxy-PAHs.

  13. Hydrodynamic calculation of a filter washing in liquids type used in containment venting systems

    International Nuclear Information System (INIS)

    Reyes G, A. A.; Sainz M, E.; Ortiz V, J.

    2015-09-01

    From the nuclear accident of Chernobyl, the European nuclear power plants have chosen to install filters on the venting pipes of the containment, whose function is to help to mitigate the consequences of a severe accident, by controlled depressurization of the containment passively through a filtered venting of the containment system. These systems are designed to relieve the internal pressure of the containment by means of the deliberate opening of pressure relief devices, either a valve or rupture disc during a severe accident and be channeled to the filter unit. In this paper the hydraulic response of a filter system of gases washing by liquid is evaluated, due to this information is necessary to estimate the effect that has the pressure increase of the contention on the discharge capacity of the venting pipes. By simulation of computational of fluid dynamics with the programs: CAELINUX-2014 and OpenFOAM, the hydrodynamic characteristics of the Multi Venturi System for gases washing from the containment, which could be included in the general model of the venting pipe, were obtained. Representative models of the Venturi tubes of each concentric area that forming the washing system were generated; and using parametric calculations the average mass flow rate established through each venturi, depending on its size and depth in which it is located inside the tank was estimated. Also, the pressure and mass flow rate required to activate each concentric area depending on the pressure and mass load from the containment were calculated, to estimate the maximum flow that is established through the filter. Finally, the velocity profiles and the characteristic pressure at which each area operates as well as the pressure drop of local and global discharge also were calculated. (Author)

  14. Washing and chilling as critical control points in pork slaughter hazard analysis and critical control point (HACCP) systems.

    Science.gov (United States)

    Bolton, D J; Pearce, R A; Sheridan, J J; Blair, I S; McDowell, D A; Harrington, D

    2002-01-01

    The aim of this research was to examine the effects of preslaughter washing, pre-evisceration washing, final carcass washing and chilling on final carcass quality and to evaluate these operations as possible critical control points (CCPs) within a pork slaughter hazard analysis and critical control point (HACCP) system. This study estimated bacterial numbers (total viable counts) and the incidence of Salmonella at three surface locations (ham, belly and neck) on 60 animals/carcasses processed through a small commercial pork abattoir (80 pigs d(-1)). Significant reductions (P HACCP in pork slaughter plants. This research will provide a sound scientific basis on which to develop and implement effective HACCP in pork abattoirs.

  15. Bergmann eitab kurikuulsa ERA Panga üldkoosoleku võltsitust / Väinu Rozental

    Index Scriptorium Estoniae

    Rozental, Väinu, 1957-

    2002-01-01

    ERA Panga eksjuht Andres Bergmann kinnitas kohtus, et protokoll panga aktsionäride üldkoosoleku kohta, mis vabastas kohustustest panga ees kuus äriühingut ja Tarmo Rubeni, polnud tagantjärele vormistatud

  16. Countercurrent soil washing system for remediation of viscous hydrocarbons, heavy metals, radionuclides

    International Nuclear Information System (INIS)

    Kuhlman, M.I.; Karlsson, M.K.; Downie, C.A.

    1995-01-01

    Drying augers and multicell DAF tanks are excellent machines in which to countercurrently wash soil and remove hazardous hydrocarbons, metals or radionuclides. An auger works well because it preferentially moves soil along one side of its trough. Thus, when enough high pressure and temperature water jets are placed along that path, contaminants can be melted, or dissolved and scoured from the soil. Contaminants and fines flow down the opposite side of the auger and out for extraction in a series of flotation tanks. Countercurrent washing of the silt results when soil settles in tanks through rising water and air bubbles then is pumped through cyclones placed above the next DAF tank of the series. LNAPLs, DNAPLs, or metallic contaminants made hydrophobic by chemicals in the system are removed at the overflow of the cyclones or by flotation in the tanks. The overflow from the cyclones and DAF tanks flows into the previous tank of the series. Examples of contaminants remediated include; arsenic, cadmium, lead and mercury, Naturally Occurring Radioactive Materials (NORM), uranium, solid oils, polyaromatic hydrocarbons in creosote and coal tars, and polychlorinated hydrocarbons

  17. Gamma-radiation produces abnormal Bergmann fibers and ectopic granule cells in mouse cerebellar cortex

    International Nuclear Information System (INIS)

    Inouye, Minoru; Hayasaka, Shizu; Funahashi, Atsushi; Yamamura, Hideki

    1992-01-01

    Morphological changes in Bergmann glial fibers in the developing cerebellar cortex produced by exposure to gamma-rays were investigated in association with ectopic granule cells. Six-day-old mice that had been exposed to 3 Gy of gamma-radiation were killed 6 hours after exposure or at 7 through 30 days of age. Their cerebella were examined histologically and immunohistochemically for glial fibrillary acidic protein in Bergmann fibers. Extensive cell death took place in the external granular layer (EGL) of the cerebellum from 6 through 24 hours after exposure. This led to the thinning of the EGL and a decrease in the number of migrating cells in the molecular layer. The number of Bergmann cells was not decreased, but the fibers in the molecular layer were distorted; whereas, in the control these fibers were straight and perpendicular to the pial surface. The EGL began to recover 2 days after exposure, and abnormally oriented migrating cells were seen. At 17 days of age, some cell clustering was observed in the molecular layer of the irradiated cerebellum. Distortion of the Bergmann fibers was marked in regions where ectopic granule cells appeared at 30 days of age. These findings suggest that the distortion of Bergmann fibers leads to the production of ectopic granule cells after exposure to gamma-radiation. (author)

  18. Evaluation and comparison of closed-loop wash-water system

    International Nuclear Information System (INIS)

    Whitney, P.M.; Greer, C.R.

    1991-01-01

    Effluent from vehicle and equipment cleaning is known to contain a variety of potential pollutants, the most common being hydrocarbons and suspended solids. Proper treatment and discharge of this effluent is a growing concern as environmental awareness increases. In the United States, discharge of this effluent to municipal sewage treatment systems requires a permit from local authorities, discharge to surface waters requires a federal permit and, in most cases, discharge to the ground in prohibited. Furthermore, discharge to ground and surface waters can cause soil or groundwater contamination resulting in property devaluation, adverse impact on human health, fines from regulatory agencies, expensive cleanup and negative publicity. Effluent from vehicle washing typically does not meet the minimum pollutant levels allowed by regulatory agencies for discharge to surface waters or sewage treatment plants. Because of the liability associated with discharge to ground and surface waters and the difficulty in meeting municipal sewer discharge permit requirements, closed-loop wastewater treatment is an attractive alternative to discharge. Evaluation and comparison of systems from each category constitute the basis of this paper. Factors involved in selecting a system and available water-treatment technologies are discussed. The conclusion summarizes the results of the system comparison and makes recommendations for selecting and installing closed-loop water treatment systems for vehicle and equipment cleaning

  19. Soil washing

    International Nuclear Information System (INIS)

    Neuman, R.S.; Diel, B.N.; Halpern, Y.

    1992-01-01

    Disposal of soils or sludges contaminated with organic and inorganic compounds is a major problem for environmental remedial activities, hazardous waste generators, and the disposal industry. This paper reports that many of these wastes can be effectively treated utilizing soil washing technology. CWM has been developing soil washing technology over the past few years, with extensive work being conducted on the bench scale. These studies have demonstrated consistently high removal efficiencies (95-99%) for a wide variety of PCB and petroleum hydrocarbon contaminated waste. Recently, a comprehensive study examining the removal of both organic and inorganic contraminants from two different types of surrogate soil matrices was completed. In addition to establishing the range of contaminants that can be removed from soil, a method for surfactant/water separation was evaluated. For example, using a thermal phase separation method, approximately 90% of the surfactant could be recovered from the water

  20. Treatment of Wastewater From Car Washes Using Natural Coagulation and Filtration System

    Science.gov (United States)

    Al-Gheethi, A. A.; Mohamed, R. M. S. R.; Rahman, M. A. A.; Johari, M. R.; Kassim, A. H. M.

    2016-07-01

    Wastewater generated from carwash is one of the main wastewater resources, which contribute effectively in the increasing of environmental contamination due to the chemical characteristics of the car wastes. The present work aimed to develop an integrated treatment system for carwash wastewater based on coagulation and flocculation using Moringa oleifera and Ferrous Sulphate (FeSO4.7H2O) as well as natural filtration system. The carwash wastewater samples were collected from carwash station located at Parit Raja, Johor, Malaysia. The treatment system of car wash wastewater was designed in the lab scale in four stages included, aeration, coagulation and flocculation, sedimentation and filtration. The coagulation and flocculation unit was carried out using different dosage (35, 70, 105 and 140 mg L-1) of M. oleifera and FeSO4.7H2O, respectively. The efficiency of the integrated treatment system to treat carwash wastewater and to meet Environmental Quality Act (EQA 1974) was evaluated based on the analysis of pH, dissolved oxygen (DO), chemical oxygen demand (COD) and turbidity (NTU). The integrated treatment system was efficient for treatment of raw carwash wastewater. The treated carwash wastewaters meet EQA 1974 regulation 2009 (Standards A) in the term of pH and DO while, turbidity and COD reduced in the wastewater to meet Standards B. The integrated treatment system designed here with natural coagulant (M. oleifera) and filtration unit were effective for primary treatment of carwash wastewater before the final disposal or to be reused again for carwash process.

  1. Fluoride exposure regulates the elongation phase of protein synthesis in cultured Bergmann glia cells.

    Science.gov (United States)

    Flores-Méndez, Marco; Ramírez, Diana; Alamillo, Nely; Hernández-Kelly, Luisa C; Del Razo, Luz María; Ortega, Arturo

    2014-08-17

    Fluoride is an environmental pollutant present in dental products, food, pesticides and water. The latter, is the greatest source of exposure to this contaminant. Structural and functional damages to the central nervous system are present in exposed population. An established consequence of the neuronal is the release of a substantial amount of glutamate to the extracellular space, leading to an excitotoxic insult. Glutamate exerts its actions through the activation of specific plasma membrane receptors and transporters present in neurons and in glia cells and it is the over-activation of glutamate receptors and transporters, the biochemical hallmark of neuronal and oligodendrocyte cell death. In this context, taking into consideration that fluoride leads to degeneration of cerebellar cells, we took the advantage of the well-established model of cerebellar Bergmann glia cultures to gain insight into the molecular mechanisms inherent to fluoride neurotoxicity that might be triggered in glia cells. We could establish that fluoride decreases [(35)S]-methionine incorporation into newly synthesized polypeptides, in a time-dependent manner, and that this halt in protein synthesis is the result of a decrease in the elongation phase of translation, mediated by an augmentation of eukaryotic elongation factor 2 phosphorylation. These results favor the notion of glial cells as targets of fluoride toxicity and strengthen the idea of a critical involvement of glia cells in the function and dysfunction of the brain. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  2. Suitability of olive oil washing water as an electron donor in a feed batch operating bio-electrochemical system

    Directory of Open Access Journals (Sweden)

    F. G. Fermoso

    2017-06-01

    Full Text Available Olive oil washing water derived from the two-phase manufacturing process was assessed as an electron donor in a bio-electrochemical system (BES operating at 35 ºC. Start-up was carried out by using acetate as a substrate for the BES, reaching a potential of around +680 mV. After day 54, BES was fed with olive oil washing water. The degradation of olive oil washing water in the BES generated a maximum voltage potential of around +520 mV and a Chemical Oxygen Demand (COD removal efficiency of 41%. However, subsequent loads produced a decrease in the COD removal, while current and power density diminished greatly. The deterioration of these parameters could be a consequence of the accumulation of recalcitrant or inhibitory compounds, such as phenols. These results demonstrated that the use of olive oil washing water as an electron donor in a BES is feasible, although it has to be further investigated in order to make it more suitable for a real application.

  3. Suitability of olive oil washing water as an electron donor in a feed batch operating bio-electrochemical system

    International Nuclear Information System (INIS)

    Fermoso, F.G.; Fernández-Rodríguez, M.J.; Jiménez-Rodríguez, A.; Serrano, A.; Borja, R.

    2017-01-01

    Olive oil washing water derived from the two-phase manufacturing process was assessed as an electron donor in a bio-electrochemical system (BES) operating at 35 ºC. Start-up was carried out by using acetate as a substrate for the BES, reaching a potential of around +680 mV. After day 54, BES was fed with olive oil washing water. The degradation of olive oil washing water in the BES generated a maximum voltage potential of around +520 mV and a Chemical Oxygen Demand (COD) removal efficiency of 41%. However, subsequent loads produced a decrease in the COD removal, while current and power density diminished greatly. The deterioration of these parameters could be a consequence of the accumulation of recalcitrant or inhibitory compounds, such as phenols. These results demonstrated that the use of olive oil washing water as an electron donor in a BES is feasible, although it has to be further investigated in order to make it more suitable for a real application. [es

  4. Evaluation of genotoxicity of liquid effluents from gas washing systems by means of bioassay Trad-MCN

    International Nuclear Information System (INIS)

    Machado, Alessandra Carla Fattori Ergesse; Alves, Edenise Segala

    2007-01-01

    In the gas washing systems the gaseous emissions from a facility are forced through an absorbing liquid preventing pollutants to be dispersed into the atmosphere. In the Centro Tecnologico da Marinha em Sao Paulo/Centro Experimental Aramar (CEA), the gas washing are used to control the emissions from the uranium enrichment facilities. Uranium. fluoride, ammonia and hydrogen fluoride are the main contaminants, all heavily toxic. Biological assays, using plants or other living organisms, have been used to assess genotoxic agents in the environment. Among the bioassays using plants, the Trad-MCN has been used extensively, as it allows the evaluation of liquid or gaseous contaminants. The species Tradescantia pallida (Rose) was exposed in a dynamic system to liquid effluents from CEA. A positive control was the exposure to formaldehyde 10% in water, known as a very toxic solution, and the negative control was the exposure to filtered air. The protocol established by Ma (1983) for hybrid clones and validated for the T. pallida by Guimaraes (2003) was used to perform the Trad-MCN assays. Only preparations containing early tetrads were scored. In that context, the present study objectifies to evaluate, by the Trad-MCN bioassay, the genotoxicity of the solution from the gas washing and, also, evaluate the efficiency of that system. The results obtained show that the T. pallida is a sensitive bioindicator for the pollutants tested and can be useful for in vitro environmental monitoring under controlled conditions. (author)

  5. Evaluation of genotoxicity of liquid effluents from gas washing systems by means of bioassay Trad-MCN

    Energy Technology Data Exchange (ETDEWEB)

    Machado, Alessandra Carla Fattori Ergesse [Centro Tecnologico da Marinha em Sao Paulo (CTMSP), SP (Brazil). Div. de Monitoracao Ambiental], E-mail: alessandra@ctmsp.mar.mil.br; Alves, Edenise Segala [Instituto de Botanica de Sao Paulo, SP (Brazil). Secao de Anatomia], E-mail: ealves@ibot.sp.gov.br

    2007-07-01

    In the gas washing systems the gaseous emissions from a facility are forced through an absorbing liquid preventing pollutants to be dispersed into the atmosphere. In the Centro Tecnologico da Marinha em Sao Paulo/Centro Experimental Aramar (CEA), the gas washing are used to control the emissions from the uranium enrichment facilities. Uranium. fluoride, ammonia and hydrogen fluoride are the main contaminants, all heavily toxic. Biological assays, using plants or other living organisms, have been used to assess genotoxic agents in the environment. Among the bioassays using plants, the Trad-MCN has been used extensively, as it allows the evaluation of liquid or gaseous contaminants. The species Tradescantia pallida (Rose) was exposed in a dynamic system to liquid effluents from CEA. A positive control was the exposure to formaldehyde 10% in water, known as a very toxic solution, and the negative control was the exposure to filtered air. The protocol established by Ma (1983) for hybrid clones and validated for the T. pallida by Guimaraes (2003) was used to perform the Trad-MCN assays. Only preparations containing early tetrads were scored. In that context, the present study objectifies to evaluate, by the Trad-MCN bioassay, the genotoxicity of the solution from the gas washing and, also, evaluate the efficiency of that system. The results obtained show that the T. pallida is a sensitive bioindicator for the pollutants tested and can be useful for in vitro environmental monitoring under controlled conditions. (author)

  6. Comparison of three different fat graft preparation methods: gravity separation, centrifugation, and simultaneous washing with filtration in a closed system.

    Science.gov (United States)

    Zhu, Min; Cohen, Steven R; Hicok, Kevin C; Shanahan, Rob K; Strem, Brian M; Yu, Johnson C; Arm, Douglas M; Fraser, John K

    2013-04-01

    Successful long-term volume retention of an autologous fat graft is problematic. The presence of contaminating cells, tumescent fluid, and free lipid in the graft contributes to disparate outcomes. Better preparation methods for the fat graft before transplantation may significantly improve results. Subcutaneous fat from 22 donors was divided and processed using various graft preparation methods: (1) no manipulation control, (2) gravity separation, (3) Coleman centrifugation, and (4) simultaneous washing with filtration using a commercially available system (Puregraft; Cytori Therapeutics, Inc., San Diego, Calif.). Fat grafts from various preparation methods were examined for free lipid, aqueous liquid, viable tissue, and blood cell content. Adipose tissue viability was determined by measuring glycerol release after agonist induction of lipolysis. All test graft preparation methods exhibited significantly less aqueous fluid and blood cell content compared with the control. Grafts prepared by washing with filtration exhibited significantly reduced blood cell and free lipid content, with significantly greater adipose tissue viability than other methods. Washing with filtration within a closed system produces a fat graft with higher tissue viability and lower presence of contaminants compared with grafts prepared by alternate methods.

  7. Porovnání dopravních systémů Bergmann a Annaburger v podnicích zemědělské prvovýroby.

    OpenAIRE

    HAVLÍK, Josef

    2011-01-01

    This thesis compares two tractor traffic exchange systems, Bergmann and Annaburger, in two companies of basic agriculture industry. Tractor traffic systems are composed of towing and exchange vehicle which can be a carrier of several types of vehicle body. Bed, spreader and cistern are concerned in this case. Engineering chracteristics and operational experiences of every single exchange system were compared. Futher functionality, time demandingness of body exchange, machine operating comfort...

  8. Reappraisal of Bergmann glial cells as modulators of cerebellar circuit function

    Directory of Open Access Journals (Sweden)

    Chris I De Zeeuw

    2015-07-01

    Full Text Available Just as there is a huge morphological and functional diversity of neuron types specialized for specific aspects of information processing in the brain, astrocytes have equally distinct morphologies and functions that aid optimal functioning of the circuits in which they are embedded. One type of astrocyte, the Bergmann glial cell of the cerebellum, is a prime example of a highly diversified astrocyte type, the architecture of which is adapted to the cerebellar circuit and facilitates an impressive range of functions that optimize information processing in the adult brain. In this review we expand on the function of the Bergmann glial cell in the cerebellum to highlight the importance of astrocytes not only in housekeeping functions, but also in contributing to plasticity and information processing in the cerebellum.

  9. Nasal Wash Treatment

    Science.gov (United States)

    ... Medications Alternative Therapies Nasal Wash Treatment Nasal Wash Treatment Make an Appointment Ask a Question Refer Patient The Centers for Disease Control (CDC) guidelines for preparing water used in a nasal wash are listed below. Many ...

  10. Testing Bergmann's rule and the Rosenzweig hypothesis with craniometric studies of the South American sea lion.

    Science.gov (United States)

    Sepúlveda, Maritza; Oliva, Doris; Duran, L René; Urra, Alejandra; Pedraza, Susana N; Majluf, Patrícia; Goodall, Natalie; Crespo, Enrique A

    2013-04-01

    We tested the validity of Bergmann's rule and Rosenzweig's hypothesis through an analysis of the geographical variation of the skull size of Otaria flavescens along the entire distribution range of the species (except Brazil). We quantified the sizes of 606 adult South American sea lion skulls measured in seven localities of Peru, Chile, Uruguay, Argentina, and the Falkland/Malvinas Islands. Geographical and environmental variables included latitude, longitude, and monthly minimum, maximum, and mean air and ocean temperatures. We also included information on fish landings as a proxy for productivity. Males showed a positive relationship between condylobasal length (CBL) and latitude, and between CBL and the six temperature variables. By contrast, females showed a negative relationship between CBL and the same variables. Finally, female skull size showed a significant and positive correlation with fish landings, while males did not show any relationship with this variable. The body size of males conformed to Bergmann's rule, with larger individuals found in southern localities of South America. Females followed the converse of Bergmann's rule at the intraspecific level, but showed a positive relationship with the proxy for productivity, thus supporting Rosenzweig's hypothesis. Differences in the factors that drive body size in females and males may be explained by their different life-history strategies. Our analyses demonstrate that latitude and temperature are not the only factors that explain spatial variation in body size: others such as food availability are also important for explaining the ecogeographical patterns found in O. flavescens.

  11. Development of a combined soil-wash/in-furnace vitrification system for soil remediation at DOE sites

    International Nuclear Information System (INIS)

    Pegg, I.L.; Guo, Y.; Lahoda, E.J.; Lai, Shan-Tao; Muller, I.S.; Ruller, J.; Grant, D.C.

    1993-01-01

    This report addresses research and development of technologies for treatment of radioactive and hazardous waste streams at DOE sites. Weldon Spring raffinate sludges were used in a direct vitrification study to investigate their use as fluxing agents in glass formulations when blended with site soil. Storm sewer sediments from the Oak Ridge, TN, Y-12 facility were used for soil washing followed by vitrification of the concentrates. Both waste streams were extensively characterized. Testing showed that both mercury and uranium could be removed from the Y-12 soil by chemical extraction resulting in an 80% volume reduction. Thermal desorption was used on the contaminant-enriched minority fraction to separate the mercury from the uranium. Vitrification tests demonstrated that high waste loading glasses could be produced from the radioactive stream and from the Weldon Spring wastes which showed very good leach resistance, and viscosities and electrical conductivities in the range suitable for joule-heated ceramic melter (JHCM) processing. The conceptual process described combines soil washing, thermal desorption, and vitrification to produce clean soil (about 90% of the input waste stream), non-radioactive mercury, and a glass wasteform; the estimated processing costs for that system are about $260--$400/yd 3 . Results from continuous melter tests performed using Duratek's advanced JHCM (Duramelter) system are also presented. Since life cycle cost estimates are driven largely by volume reduction considerations, the large volume reductions possible with these multi-technology, blended waste stream approaches can produce a more leach resistant wasteform at a lower overall cost than alternative technologies such as cementation

  12. Late Washing efficiency

    International Nuclear Information System (INIS)

    Morrissey, M.F.

    1992-01-01

    Interim Waste Technology has demonstrated the Late Washing concept on the Experimental Laboratory Filter (ELF) at TNX. In two tests, washing reduced the [NO 2 - ] from 0.08 M to approximately 0.01 M on slurries with 2 year equivalent radiation exposures and 9.5 wt. % solids. For both washes, the [NO 2 - ] decreased at rates near theoretical for a constant volume stirred vessel, indicating approximately l00% washing efficiency. Permeate flux was greater than 0.05 gpm/ft 2 for both washes at a transmembrane pressure of 50 psi and flow velocity of 9 ft/sec

  13. Soil washing and post-wash biological treatment of petroleum hydrocarbon contaminated soils

    OpenAIRE

    Bhandari, Alok

    1992-01-01

    A laboratory scale study was conducted to investigate the treatability of petroleum contaminated soils by soil washing and subsequent biological treatment of the different soil fractions. In addition to soils obtained from contaminated sites, studies were also performed on soils contaminated in the laboratory. Soil washing was performed using a bench-scale soil washing system. Washing was carried out with simultaneous fractionation of the bulk soil into sand, silt and clay fractions. Cl...

  14. 21 CFR 1250.87 - Wash water.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Wash water. 1250.87 Section 1250.87 Food and Drugs... Sanitation Facilities and Conditions on Vessels § 1250.87 Wash water. Where systems installed on vessels for wash water, as defined in § 1250.3(n), do not comply with the requirements of a potable water system...

  15. Application of soil washing system to the volume reduction of radioactively contaminated soils and automated treatment of sludge cake

    International Nuclear Information System (INIS)

    Mouri, Mitsuo; Tsuchida, Mitsuru; Baba, Naoki; Nakajima, Takuma

    2013-01-01

    The pilot plant study was intended to evaluate; a) the removal efficiency of radioactive Cs, b) the volume reduction rate of feed soils, c) the volumetric rate and concentration rate of discharged sludge cake, and d) the effect of radiation exposure reduction by automated filter press unit and automated packing unit of sludge cake. As a result of this study, following observations were made; 1) the radioactive Cs content of clean sands ranged 882∼2,940 Bq/kg as compared to the feed soils of 8,790 to 26,270 Bq/kg, 2) the removal efficiency of radioactive Cs ranged 84∼92% of feed soils, 3) the volume reduction rate of feed soils ranged 70∼86% (ave. 82%), and 4) the automated filter press unit and the automated packing system of sludge cake were helpful for workers in reducing radiation exposure. It is concluded that soil washing system can effectively reduce volume of radioactively contaminated soils and can be practically used in Fukushima for remediation of soils. (author)

  16. Technology evaluation report: Biotrol Soil Washing System for treatment of a wood-preserving site. Volume 2, Part B

    International Nuclear Information System (INIS)

    Skovronek, H.S.; Ellis, W.; Evans, J.; Kitaplioglu, O.; McPherson, J.

    1991-12-01

    The SITE Program demonstration of one configuration of the BioTrol Soil Washing System (BSWS) was conducted to obtain reliable performance and cost data that can be used to evaluate the potential applicability of the technology as a remediation alternative for sites contaminated with hazardous wastes. The BSWS treatment train used in the study consists of three technologies: a soil washer; an aqueous treatment system; and a slurry bio-reactor. The demonstration was carried out at the MacGillis and Gibbs Superfund site in New Brighton, MN. The report analyzes the results from the SITE demonstration. It includes discussion of the operation of the three separate treatment technologies (SW, SBR, and BATS) evaluated in the test and provides flow diagrams, a summary of the sampling and analytical programs, an economic analysis, and a quality assurance/quality control evaluation of the data. Conclusions were reached concerning the technology's suitability for use in remediations involving both similar and different materials at other sites

  17. Enhanced sludge washing evaluation plan

    Energy Technology Data Exchange (ETDEWEB)

    Jensen, R.D.

    1994-09-01

    The Tank Waste Remediation System (TWRS) Program mission is to store, treat, and immobilize highly radioactive Hanford Site waste (current and future tank waste and the strontium/cesium capsules) in an environmentally sound, safe, and cost-effective manner. The scope of the TWRS Waste Pretreatment Program is to treat tank waste and separate that waste into HLW and LLW fractions and provide additional treatment as required to feed LLW and HLW immobilization facilities. Enhanced sludge washing was chosen as the baseline process for separating Hanford tank waste sludge. Section 1.0 briefly discusses the purpose of the evaluation plan and provides the background that led to the choice of enhanced sludge washing as the baseline process. Section 2.0 provides a brief summary of the evaluation plan details. Section 3.0 discusses, in some detail, the technical work planned to support the evaluation of enhanced sludge washing. Section 4.0 briefly discusses the potential important of policy issues to the evaluation. Section 5.0 discusses the methodology to be used in the evaluation process. Section 6.0 summarizes the milestones that have been defined to complete the enhanced sludge washing evaluation and provides a summary schedule to evaluate the performance of enhanced sludge washing. References are identified in Section 7.0, and additional schedule and milestone information is provided in the appendices.

  18. Enhanced sludge washing evaluation plan

    International Nuclear Information System (INIS)

    Jensen, R.D.

    1994-09-01

    The Tank Waste Remediation System (TWRS) Program mission is to store, treat, and immobilize highly radioactive Hanford Site waste (current and future tank waste and the strontium/cesium capsules) in an environmentally sound, safe, and cost-effective manner. The scope of the TWRS Waste Pretreatment Program is to treat tank waste and separate that waste into HLW and LLW fractions and provide additional treatment as required to feed LLW and HLW immobilization facilities. Enhanced sludge washing was chosen as the baseline process for separating Hanford tank waste sludge. Section 1.0 briefly discusses the purpose of the evaluation plan and provides the background that led to the choice of enhanced sludge washing as the baseline process. Section 2.0 provides a brief summary of the evaluation plan details. Section 3.0 discusses, in some detail, the technical work planned to support the evaluation of enhanced sludge washing. Section 4.0 briefly discusses the potential important of policy issues to the evaluation. Section 5.0 discusses the methodology to be used in the evaluation process. Section 6.0 summarizes the milestones that have been defined to complete the enhanced sludge washing evaluation and provides a summary schedule to evaluate the performance of enhanced sludge washing. References are identified in Section 7.0, and additional schedule and milestone information is provided in the appendices

  19. The evolution of body size under environmental gradients in ectotherms: why should Bergmann's rule apply to lizards?

    Directory of Open Access Journals (Sweden)

    Tregenza Tom

    2008-02-01

    Full Text Available Abstract Background The impact of environmental gradients on the evolution of life history traits is a central issue in macroecology and evolutionary biology. A number of hypotheses have been formulated to explain factors shaping patterns of variation in animal mass. One such example is Bergmann's rule, which predicts that body size will be positively correlated with latitude and elevation, and hence, with decreasing environmental temperatures. A generally accepted explanation for this phenotypic response is that as body mass increases, body surface area gets proportionally smaller, which contributes to reduced rates of heat-loss. Phylogenetic and non-phylogenetic evidence reveals that endotherms follow Bergmann's rule. In contrast, while previous non-phylogenetic studies supported this prediction in up to 75% of ectotherms, recent phylogenetic comparative analyses suggest that its validity for these organisms is controversial and less understood. Moreover, little attention has been paid to why some ectotherms conform to this rule, while others do not. Here, we investigate Bergmann's rule in the six main clades forming the Liolaemus genus, one of the largest and most environmentally diverse genera of terrestrial vertebrates. A recent study conducted on some species belonging to four of these six clades concluded that Liolaemus species follow Bergmann's rule, representing the only known phylogenetic support for this model in lizards. However, a later reassessment of this evidence, performed on one of the four analysed clades, produced contrasting conclusions. Results Our results fail to support Bergmann's rule in Liolaemus lizards. Non-phylogenetic and phylogenetic analyses showed that none of the studied clades experience increasing body size with increasing latitude and elevation. Conclusion Most physiological and behavioural processes in ectotherms depend directly upon their body temperature. In cold environments, adaptations to gain heat

  20. Lack of connexin43-mediated Bergmann glial gap junctional coupling does not affect cerebellar long-term depression, motor coordination, or eyeblink conditioning

    Directory of Open Access Journals (Sweden)

    Mika Tanaka

    2008-04-01

    Full Text Available Bergmann glial cells are specialized astrocytes in the cerebellum. In the mature cerebellar molecular layer, Bergmann glial processes are closely associated with Purkinje cells, enclosing Purkinje cell dendritic synapses with a glial sheath. There is intensive gap junctional coupling between Bergmann glial processes, but their significance in cerebellar functions is not known. Connexin43 (Cx43, a major component of astrocytic gap junction channels, is abundantly expressed in Bergmann glial cells. To examine the role of Cx43-mediated gap junctions between Bergmann glial cells in cerebellar functions, we generated Cx43 conditional knockout mice with the S100b-Cre transgenic line (Cx43fl/fl:S100b-Cre, which exhibited a significant loss of Cx43 in the Bergmann glial cells and astrocytes in the cerebellum with a postnatal onset. The Cx43fl/fl:S100b-Cre mice had normal cerebellar architecture. Although gap junctional coupling between the Bergmann glial cells measured by spreading of microinjected Lucifer yellow was virtually abolished in Cx43fl/fl:S100b-Cre mice, electrophysiologic analysis revealed that cerebellar long-term depression could be induced and maintained normally in thier cerebellar slices. In addition, at the behavioral level, Cx43fl/fl:S100b-Cre mice had normal motor coordination in the rotarod task and normal conditioned eyelid response. Our findings suggest that Cx43-mediated gap junctional coupling between Bergmann glial cells is not necessary for the neuron-glia interactions required for cerebellum-dependent motor coordination and motor learning.

  1. Washing method of filter

    International Nuclear Information System (INIS)

    Izumidani, Masakiyo; Tanno, Kazuo.

    1978-01-01

    Purpose: To enable automatic filter operation and facilitate back-washing operation by back-washing filters used in a bwr nuclear power plant utilizing an exhaust gas from a ventilator or air conditioner. Method: Exhaust gas from an exhaust pipe of an ventilator or air conditioner is pressurized in a compressor and then introduced in a back-washing gas tank. Then, the exhaust gas pressurized to a predetermined pressure is blown from the inside to the outside of a filter to thereby separate impurities collected on the filter elements and introduce them to a waste tank. (Furukawa, Y.)

  2. Counter current decantation washing of HLW sludge

    International Nuclear Information System (INIS)

    Brooke, J.N.; Peterson, R.A.

    1997-01-01

    The Savannah River Site (SRS) has 51 High Level Waste (HLW) tanks with typical dimensions 25.9 meters (85 feet) diameter and 10 meters (33 feet) high. Nearly 114 million liters (30 M gallons) of HLW waste is stored in these tanks in the form of insoluble solids called sludge, crystallized salt called salt cake, and salt solutions. This waste is being converted to waste forms stable for long term storage. In one of the processes, soluble salts are washed from HLW sludge in preparation for vitrification. At present, sludge is batch washed in a waste tank with one or no reuse of the wash water. Sodium hydroxide and sodium nitrite are added to the wash water for tank corrosion protection; the large volumes of spent wash water are recycled to the evaporator system; additional salt cake is produced; and sodium carbonate is formed in the washed sludge during storage by reaction with CO 2 from the air. High costs and operational concerns with the current washing process prompts DOE and WSRC to seek an improved washing method. A new method should take full advantage of the physical/chemical properties of sludge, experience from other technical disciplines, processing rate requirements, inherent process safety, and use of proven processes and equipment. Counter current solids washing is a common process in the minerals processing and chemical industries. Washing circuits can be designed using thickeners, filters or centrifuges. Realizing the special needs of nuclear work and the low processing rates required, a Counter Current Decantation (CCD) circuit is proposed using small thickeners and fluidic pumps

  3. Probabilistics since WASH-1400

    International Nuclear Information System (INIS)

    Whitehead, N.E.

    1980-01-01

    Literature since the issuing of WASH-1400 reactor safety study shows that although the methodology has been attacked, it stands criticism well. Contrary to the aim of the study, which was to give a realistic, rather than a conservative risk estimate, there are many conservatisms in it. The strongly attacked treatment of common mode failure involving the square bounding model is shown here to be very likely to give correct results - and the applications of it in WASH-1400 do not often give results different from using the mean instead of the median. The Three-Mile Island accident is not such as to change the conclusions of WASH-1400 regarding core melt probabilities

  4. 33 CFR 157.124 - COW tank washing machines.

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false COW tank washing machines. 157... OIL IN BULK Crude Oil Washing (COW) System on Tank Vessels Design, Equipment, and Installation § 157.124 COW tank washing machines. (a) COW machines must be permanently mounted in each cargo tank. (b...

  5. Soil washing technology evaluation

    International Nuclear Information System (INIS)

    Suer, A.

    1995-04-01

    Environmental Restoration Engineering (ERE) continues to review innovative, efficient, and cost effective technologies for SRS soil and/or groundwater remediation. As part of this effort, this technical evaluation provides review and the latest information on the technology for SRS soil remediation. Additional technology evaluation reports will be issued periodically to update these reports. The purpose of this report is to review the soil washing technology and its potential application to SRS soil remediation. To assess whether the Soil Washing technology is a viable option for SRS soil remediation, it is necessary to review the technology/process, technology advantages/limitations, performance, applications, and cost analysis

  6. Evidence for Bergmann's Rule and Not Allopatric Subspeciation in the Threatened Kaka (Nestor meridionalis).

    Science.gov (United States)

    Dussex, Nic; Sainsbury, James; Moorhouse, Ron; Jamieson, Ian G; Robertson, Bruce C

    2015-01-01

    Species of conservation concern characterized by small and declining populations greatly benefit from proactive management approaches such as population translocations. Because they often show intra-specific genetic and phenotypic variation, which can result from drift or differential selective pressures between habitats, understanding the distribution of such variation and its underlying processes is a prerequisite to develop effective management guidelines. Indeed, translocations among genetically differentiated populations potentially locally adapted are discouraged in order to avoid outbreeding depression, while translocations among populations characterized by high gene flow with no evidence for local adaptation are encouraged. Here, we first test whether 2 recognized subspecies, the North Island kaka (Nestor meridionalis septentrionalis) and South Island kaka (Nestor meridionalis meridionalis) of New Zealand fit a scenario of allopatric subspeciation following the separation of the North and South Islands at the end of the Pleistocene using 1 mtDNA (n = 96) and 9 microsatellite markers (n = 126). We then test whether morphological differences among the 2 subspecies support a pattern of local adaptation, comparing phenotypic divergence (P ST) and the level of divergence by drift alone (F ST) among populations. We find little population structure between islands, ruling out allopatric subspeciation in kaka. Further, P ST exceeds F ST, supporting an adaptive latitudinal size cline consistent with Bergmann's rule. These results therefore suggest that using neutral genetic diversity alone can be misleading when identifying management units and that the nature of phenotypic variation should be considered in translocations efforts. We finally discuss North and South Island management units but suggest that cross-island translocation be allowed. © The American Genetic Association. 2015. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  7. Wash Your Hands

    Centers for Disease Control (CDC) Podcasts

    2010-03-08

    This video shows kids how to properly wash their hands, one of the most important steps we can take to avoid getting sick and spreading germs to others.  Created: 3/8/2010 by Centers for Disease Control and Prevention (CDC).   Date Released: 3/8/2010.

  8. Soil washing treatability study

    International Nuclear Information System (INIS)

    Krstich, M.

    1995-12-01

    Soil washing was identified as a viable treatment process option for remediating soil at the FEMP Environmental Management Project (FEMP). Little information relative to the specific application and potential effectiveness of the soil washing process exists that applies to the types of soil at the FEMP. To properly evaluate this process option in conjunction with the ongoing FEMP Remedial Investigation/Feasibility Study (RI/FS), a treatability testing program was necessary to provide a foundation for a detailed technical evaluation of the viability of the process. In August 1991, efforts were initiated to develop a work plan and experimental design for investigating the effectiveness of soil washing on FEMP soil. In August 1992, the final Treatability Study Work Plan for Operable Unit 5: Soil Washing (DOE 1992) was issued. This document shall be referenced throughout the remainder of this report as the Treatability Study Work Plan (TSWP). The purpose of this treatability study was to generate data to support initial screening and the detailed analysis of alternatives for the Operable Unit 5 FS

  9. Irreversible Wash Aid Additive for Cesium Mitigation: Phase II. Selection and/or Modification of COTS Field Portable Waste Water Systems

    International Nuclear Information System (INIS)

    Kaminski, Michael; Mertz, Carol; Kivenas, Nadia; Magnuson, Matthew

    2015-01-01

    After an accidental or malicious release of radioactivity, large urban areas may be contaminated, compromising response efforts by first responders and law enforcement officials. In addition, some public services (e.g., drinking water and wastewater treatment, electrical power distribution, etc.) may be disrupted. In such an event, it may be important to deploy mitigation efforts in certain areas to restore response activities and public services (Fig. S-1). This report explores the state-of-the-art approach for a system to rapidly return critical infrastructure components to service following a cesium-137 (Cs-137) radiological dispersal device (RDD) release while avoiding the spread of Cs-137 beyond its original deposition area and minimizing the amount of Cs-137-contaminated wastewater. Specifically, we describe a wash system consisting of chemical additives added to fire hydrant water and irreversible solid sequestering agents added as the water is collected and treated for recycle in situ. The wash system is intended to be a rapidly deployable, cost-effective means of mitigating an urban setting for the purpose of restoring critical infrastructure and operational activities after a radiological release.

  10. Wash-oil problem

    Energy Technology Data Exchange (ETDEWEB)

    Chlosta, J

    1941-01-01

    Meier-Grolman and others have deduced from experimental studies of the vapor pressure of solutions of benzene in paraffin oil and Solway oil-paraffin oil mixtures that the higher the proportion of aliphatic compounds in a wash oil, the less suitable it is for benzene scrubbing. This generalization is not supported. Paraffin oils from brown-coal tar and low viscous oils from the Fischer-Tropsch hydrocarbon synthesis process are both being successfully used for benzene scrubbing.

  11. Geographical variations of the skull in the red fox Vulpes vulpes on the Japanese Islands: an exception to Bergmann's rule.

    Science.gov (United States)

    Oishi, Takuya; Uraguchi, Kohji; Abramov, Alexei V; Masuda, Ryuichi

    2010-12-01

    In order to clarify the morphological differences between two subspecies of the red fox (Vulpes vulpes) on the Japanese Islands and test the validity of Bergmann's rule, we examined geographical variations in 25 cranial and 24 dental characters in V. v. schrencki from Hokkaido and V. v. japonica from the other main islands of Japan (Honshu, Shikoku, and Kyushu). Many skull measurements, including the male greatest length, condylobasal length, and the length of upper and lower tooth rows, were significantly larger for V. v. japonica than for V. v. schrencki, whereas most tooth measurements, especially the length of molars and premolars, in V. v. schrencki were larger than those in V. v. japonica. Although the two subspecies were morphologically well-differentiated from each other, the results did not support that they have evolved following Bergmann's rule of adaptation to cold climates. Based on consideration of the relatively large differences of their tooth sizes, which are not easily influenced by food abundance, and previous genetic research on the different migration histories of the two subspecies, the morphological differences detected in the present study may have resulted not only from the present ecological differences between the two subspecies, but also from the difference of migration history and evolutionary constraints.

  12. Effect on the performance with the washing of the gas turbines Ruston TB5000 with a system of washing out of line in high contamination conditions; Efecto en el rendimiento con el lavado de las turbinas de gas Ruston TB5000 con un sistema de lavado fuera de linea en condiciones de alta contaminacion

    Energy Technology Data Exchange (ETDEWEB)

    Diaz Diaz, Carlos Rodolfo; Aboites Davila, Fernando [CIATEQ, A.C., Queretaro (Mexico); Rocha Orozco, Moises [PEMEX Refinacion, Mexico, D.F. (Mexico)

    2007-11-15

    This paper shows the effects on the gas turbine performance with a washing system out of line, based on liquid detergent and water for the case of 2 Ruston TB5000 gas turbines located in conditions of high contamination in the atmosphere such as ashes, high humidity and temperature. The investigation was realized making periodical measurements of the main parameters of the turbo-pump during 1 year of operation with load conditions without stopping of about 125 mbpd (million of barrels per day) of gas LP. This article suggests how the low performance of the turbines in a hostile atmosphere can be improved and which could be the limitations of the washing systems based on liquid detergents. The data of the washing sessions were collected during a year and studied under statistical methods creating performance curves and comparing them with curves of other machines being washed with other washing systems. [Spanish] Este trabajo muestra los efectos en el rendimiento de la turbina de gas con un sistema de lavado fuera de linea, basado en detergente liquido y agua para el caso de 2 turbinas de gas Ruston TB5000 localizados en condiciones de alta contaminacion en el ambiente como cenizas, alta humedad y temperatura. La investigacion fue realizada haciendo mediciones periodicas de los parametros principales de turbo bomba durante 1 ano de operacion con condiciones de carga sin parar de alrededor de 125 mbpd (millones de barriles por dia) de gas LP. Este articulo sugiere como se puede mejorar el bajo desempeno de las turbinas en un ambiente hostil y cuales podrian ser las limitaciones de los sistemas de lavado basados en detergentes liquidos. Los datos de las sesiones de lavado fueron recolectados durante un ano y estudiados bajo metodos estadisticos creando curvas de rendimiento y comparandolas con curvas de otras maquinas siendo lavadas con otros sistemas de lavado.

  13. Pollutants Characterization of Car Wash Wastewater

    Directory of Open Access Journals (Sweden)

    Hashim Nor Haslina

    2016-01-01

    Full Text Available The huge quantity of water consumed per car during washing cars yields the untreated effluents discharged to the stormwater system. Wastewater samples from snow car wash and two full hand service car wash station were analyzed for pH and the presence of PO43-,TP, O&G, alkalinity, TSS, NO3-, NO2-, COD and surfactant in accordance Standard Method of Water and Wastewater 2012. Two full hand wash service stations and one station of snow foam service were investigated in this study. Amongst the stations, snow foam car wash station indicates the highest concentration of PO43-, TP, O&G, TSS, COD and surfactant with the average value of 10.18 ± 0.87 mg/L, 30.93 ± 0.31 mg/L , 85.00 ± 0.64 mg/L 325.0 ± 0.6 mg/L, 485.0 ± 0.3 mg/L and 54.00 ± 2.50 mg/L as MBAS, respectively. Whereas, in parameters characterization in different stages throughout the car wash process, O&G was found to be the highest in pre soak stage, PO43-, TP, TSS and COD in washing stage and NO3- and NO2- in rinse stage. All parameters were compared to Environmental Quality (Industrial Effluent Regulations, 2009. There is a strong need to study on the characterization of car wash water in order to suggest the suitable treatment need for this type of wastewater.

  14. Radionuclide content of Las Vegas wash sediments

    International Nuclear Information System (INIS)

    Rudin, M.J.; Meyers, A.M.; Johnson, W.H.

    1996-01-01

    The Las Vegas Wash is an excavated waterway channel which drains all surface water and effluent discharge from sewage-treatment facilities from the greater Las Vegas Metropolitan Area to Lake Mead. Runoff and erosion processes are expected to transport man-made radioactivity that was deposited over the past several decades in the Las Vegas Valley. Additionally, radionuclides disposed of via the city's sanitary system are expected to accumulate in the Wash sediments. Fine and coarse sediment samples were collected at 100 m intervals and analyzed to determine the distribution of alpha- and gamma-emitting radionuclides in the lower 5,500 in of the Las Vegas Wash. Results indicate little accumulation of long-lived fission products in upstream Wash sediments. However, trace amounts of fission products measured in downstream sediments suggest the resuspension and transport of radioactive particulate matter within the Wash. Levels of naturally-occurring radionuclides found in Wash sediments were found to be consistent with levels typically found in southeast Nevada soils

  15. Oxygen and Glucose Deprivation Induces Bergmann Glia Membrane Depolarization and Ca2+ Rises Mainly Mediated by K+ and ATP Increases in the Extracellular Space

    Directory of Open Access Journals (Sweden)

    Romain Helleringer

    2017-11-01

    Full Text Available During brain ischemia, intense energy deficiency induces a complex succession of events including pump failure, acidosis and exacerbated glutamate release. In the cerebellum, glutamate is the principal mediator of Purkinje neuron anoxic depolarization during episodes of oxygen and glucose deprivation (OGD. Here, the impact of OGD is studied in Bergmann glia, specialized astrocytes closely associated to Purkinje neurons. Patch clamp experiments reveal that during OGD Bergmann glial cells develop a large depolarizing current that is not mediated by glutamate and purinergic receptors but is mainly due to the accumulation of K+ in the extracellular space. Furthermore, we also found that increases in the intracellular Ca2+ concentration appear in Bergmann glia processes several minutes following OGD. These elevations require, in an early phase, Ca2+ mobilization from internal stores via P2Y receptor activation, and, over longer periods, Ca2+ entry through store-operated calcium channels. Our results suggest that increases of K+ and ATP concentrations in the extracellular space are primordial mediators of the OGD effects on Bergmann glia. In the cerebellum, glial responses to energy deprivation-triggering events are therefore highly likely to follow largely distinct rules from those of their neuronal counterparts.

  16. 40 CFR 447.10 - Applicability; description of the oil-base solvent wash ink subcategory.

    Science.gov (United States)

    2010-07-01

    ...-base solvent wash ink subcategory. 447.10 Section 447.10 Protection of Environment ENVIRONMENTAL...-Base Solvent Wash Ink Subcategory § 447.10 Applicability; description of the oil-base solvent wash ink...-base ink where the tank washing system uses solvents. When a plant is subject to effluent limitations...

  17. Solvent wash solution

    International Nuclear Information System (INIS)

    Neace, J.C.

    1986-01-01

    This patent describes a process for removing diluent degradation products from a solvent extraction solution comprising an admixture of an organic extractant for uranium and plutonium and a non-polar organic liquid diluent, which has been used to recover uranium and plutonium from spent nuclear fuel. Comprising combining a wash solution consisting of: (a) water; and (b) a positive amount up to about, an including, 50 volume percent of at least one highly-polar water-miscible organic solvent, based on the total volume of the water and the highly-polar organic solvent, with the solvent extraction solution after uranium and plutonium values have been stripped from the solvent extraction solution, the diluent degradation products dissolving in the highly-polar organic solvent and the extractant and diluent of the extraction solution not dissolving in the highly-polar organic solvent, and separating the highly-polar organic solvent and the extraction solution to obtain a purified extraction solution

  18. Bacterial Selection during the Formation of Early-Stage Aerobic Granules in Wastewater Treatment Systems Operated Under Wash-Out Dynamics

    OpenAIRE

    Weissbrodt, David G.; Lochmatter, Samuel; Ebrahimi, Sirous; Rossi, Pierre; Maillard, Julien; Holliger, Christof

    2012-01-01

    Aerobic granular sludge is attractive for high-rate biological wastewater treatment. Biomass wash-out conditions stimulate the formation of aerobic granules. Deteriorated performances in biomass settling and nutrient removal during start-up have however often been reported. The effect of wash-out dynamics was investigated on bacterial selection, biomass settling behavior, and metabolic activities during the formation of early-stage granules from activated sludge of two wastewater treatment pl...

  19. Hand Washing: Do's and Dont's

    Science.gov (United States)

    ... hands frequently can help limit the transfer of bacteria, viruses and other microbes. Always wash your hands before: Preparing food or eating Treating wounds or caring for a sick person Inserting or removing contact lenses Always wash your hands after: Preparing food Using ...

  20. Evaluation of washing machine load potential for smart grid integration

    NARCIS (Netherlands)

    Klaassen, E.A.M.; Kobus, C.B.A.; Huijkelom, M.; Frunt, J.; Slootweg, J.G.

    2013-01-01

    This paper presents the lessons learned from a smart wash pilot, conducted with 24 employees of distribution system operator Enexis, who were equipped with an energy computer, smart washing machine, photovoltaic panels and smart meter. The pilot goal was to gain experience and knowledge about the

  1. 100 Area soil washing treatability test plan

    International Nuclear Information System (INIS)

    1993-03-01

    This test plan describes specifications, responsibilities, and general methodology for conducting a soil washing treatability study as applied to source unit contamination in the 100 Area. The objective ofthis treatability study is to evaluate the use of physical separation systems and chemical extraction methods as a means of separating chemically and radioactively contaminated soil fractions from uncontaminated soil fractions. The purpose of separating these fractions is to minimize the volume of soil requiring permanent disposal. It is anticipated that this treatability study will be performed in two phases of testing, a remedy screening phase and a remedy selection phase. The remedy screening phase consists of laboratory- and bench-scale studies performed by Battelle Pacific Northwest laboratories (PNL) under a work order issued by Westinghouse Hanford Company (Westinghouse Hanford). This phase will be used to provide qualitative evaluation of the potential effectiveness of the soil washing technology. The remedy selection phase, consists of pilot-scale testing performed under a separate service contract to be competitively bid under Westinghouse Hanford direction. The remedy selection phase will provide data to support evaluation of the soil washing technology in future feasibility studies for Interim Remedial Measures (IRMs) or final operable unit (OU) remedies. Performance data from these tests will indicate whether applicable or relevant and appropriate requirements (ARARs) or cleanup goals can be met at the site(s) by application of soil washing. The remedy selection tests wig also allow estimation of costs associated with implementation to the accuracy required for the Feasibility Study

  2. Sludge pretreatment chemistry evaluation: Enhanced sludge washing separation factors

    International Nuclear Information System (INIS)

    Colton, N.G.

    1995-03-01

    This report presents the work conducted in Fiscal Year 1994 by the Sludge Pretreatment Chemistry Evaluation Subtask for the Tank Waste Remediation System (TWRS) Tank Waste Treatment Science Task. The main purpose of this task, is to provide the technical basis and scientific understanding to support TWRS baseline decisions and actions, such as the development of an enhanced sludge washing process to reduce the volume of waste that will require high-level waste (HLW) vitrification. One objective within the Sludge Pretreatment Chemistry Evaluation Subtask was to establish wash factors for various SST (single-shell tank) sludges. First, analytical data were compiled from existing tank waste characterization reports. These data were summarized on tank-specific worksheets that provided a uniform format for reviewing and comparing data, as well as the means to verify whether the data set for each tank was complete. Worksheets were completed for 27 SST wastes. The analytical water wash data provided tank-specific information about the fraction of each component that dissolves with water, i.e., an estimate of tank-specific wash factors for evaluating tank-by-tank processing. These wash data were then used collectively to evaluate some of the wash factors that are assumed for the overall SST waste inventory; specifically, wash factors for elements that would be found primarily in sludges. The final step in this study was to incorporate the characterization and wash factor data into a spreadsheet that provides insight into the effect of enhanced sludge washing on individual tank sludges as well as for groups of sludges that may be representative of different waste types. Spreadsheet results include the estimated mass and percentage of each element that would be removed with washing and leaching. Furthermore, estimated compositions are given of the final wash and leach streams and residual solids, in terms of both concentration and dry weight percent

  3. Apparatus for washing out halogens

    Energy Technology Data Exchange (ETDEWEB)

    Pier, M; Hahn, J; Kroenig, W

    1941-03-26

    An apparatus is described for washing out of halogens and the like or liquid halogen compounds from the products, which are formed on pressure hydrogenation or splitting of carbon-containing material in the presence of halogens or halogen compounds, consisting of a washing apparatus installed between the reaction vessel and the hot separator, which is inclined in relatively small space for steam regulation and contains, with the steam, arranged baffles, especially spirals.

  4. Numerical model for a watering plan to wash out organic matter from the municipal solid waste incinerator bottom ash layer in closed system disposal facilities.

    Science.gov (United States)

    Ishii, Kazuei; Furuichi, Toru; Tanikawa, Noboru

    2009-02-01

    Bottom ash from municipal solid waste incineration (MSWI) is a main type of waste that is landfilled in Japan. The long-term elution of organic matter from the MSWI bottom ash layers is a concern because maintenance and operational costs of leachate treatment facilities are high. In closed system disposal facilities (CSDFs), which have a roof to prevent rainfall from infiltrating into the waste layers, water must be supplied artificially and its quantity can be controlled. However, the quantity of water needed and how to apply it (the intensity, period and frequency) have not been clearly defined. In order to discuss an effective watering plan, this study proposes a new washout model to clarify a fundamental mechanism of total organic carbon (TOC) elution behavior from MSWI bottom ash layers. The washout model considers three phases: solid, immobile water and mobile water. The parameters, including two mass transfer coefficients of the solid-immobile water phases and immobile-mobile water phases, were determined by one-dimensional column experiments for about 2 years. The intensity, period and frequency of watering and other factors were discussed based on a numerical analysis using the above parameters. As a result, our washout model explained adequately the elution behavior of TOC from the MSWI bottom ash layer before carbonation occurred (pH approximately 8.3). The determined parameters and numerical analysis suggested that there is a possibility that the minimum amount of water needed for washing out TOC per unit weight of MSWI bottom ash layer could be determined, which depends on the two mass transfer coefficients and the depth of the MSWI bottom ash layer. Knowledge about the fundamental mechanism of the elution behavior of TOC from the MSWI bottom ash layer before carbonation occurs, clarified by this study, will help an effective watering plan in CSDFs.

  5. Bergmann glia and the recognition molecule CHL1 organize GABAergic axons and direct innervation of Purkinje cell dendrites.

    Directory of Open Access Journals (Sweden)

    Fabrice Ango

    2008-04-01

    Full Text Available The geometric and subcellular organization of axon arbors distributes and regulates electrical signaling in neurons and networks, but the underlying mechanisms have remained elusive. In rodent cerebellar cortex, stellate interneurons elaborate characteristic axon arbors that selectively innervate Purkinje cell dendrites and likely regulate dendritic integration. We used GFP BAC transgenic reporter mice to examine the cellular processes and molecular mechanisms underlying the development of stellate cell axons and their innervation pattern. We show that stellate axons are organized and guided towards Purkinje cell dendrites by an intermediate scaffold of Bergmann glial (BG fibers. The L1 family immunoglobulin protein Close Homologue of L1 (CHL1 is localized to apical BG fibers and stellate cells during the development of stellate axon arbors. In the absence of CHL1, stellate axons deviate from BG fibers and show aberrant branching and orientation. Furthermore, synapse formation between aberrant stellate axons and Purkinje dendrites is reduced and cannot be maintained, leading to progressive atrophy of axon terminals. These results establish BG fibers as a guiding scaffold and CHL1 a molecular signal in the organization of stellate axon arbors and in directing their dendritic innervation.

  6. Inflammation-induced reversible switch of the neuron-specific enolase promoter from Purkinje neurons to Bergmann glia.

    Science.gov (United States)

    Sawada, Yusuke; Konno, Ayumu; Nagaoka, Jun; Hirai, Hirokazu

    2016-06-13

    Neuron-specific enolase (NSE) is a glycolytic isoenzyme found in mature neurons and cells of neuronal origin. Injecting adeno-associated virus serotype 9 (AAV9) vectors carrying the NSE promoter into the cerebellar cortex is likely to cause the specific transduction of neuronal cells, such as Purkinje cells (PCs) and interneurons, but not Bergmann glia (BG). However, we found BG-predominant transduction without PC transduction along a traumatic needle tract for viral injection. The enhancement of neuroinflammation by the co-application of lipopolysaccharide (LPS) with AAV9 significantly expanded the BG-predominant area concurrently with the potentiated microglial activation. The BG-predominant transduction was gradually replaced by the PC-predominant transduction as the neuroinflammation dissipated. Experiments using glioma cell cultures revealed significant activation of the NSE promoter due to glucose deprivation, suggesting that intracellularly stored glycogen is metabolized through the glycolytic pathway for energy. Activation of the glycolytic enzyme promoter in BG concurrently with inactivation in PC may have pathophysiological significance for the production of lactate in activated BG and the utilization of lactate, which is provided by the BG-PC lactate shuttle, as a primary energy resource in injured PCs.

  7. Car wash wastewater treatment and water reuse - a case study.

    Science.gov (United States)

    Zaneti, R N; Etchepare, R; Rubio, J

    2013-01-01

    Recent features of a car wash wastewater reclamation system and results from a full-scale car wash wastewater treatment and recycling process are reported. This upcoming technology comprises a new flocculation-column flotation process, sand filtration, and a final chlorination. A water usage and savings audit (22 weeks) showed that almost 70% reclamation was possible, and fewer than 40 L of fresh water per wash were needed. Wastewater and reclaimed water were characterized by monitoring chemical, physicochemical and biological parameters. Results were discussed in terms of aesthetic quality (water clarification and odour), health (pathological) and chemical (corrosion and scaling) risks. A microbiological risk model was applied and the Escherichia coli proposed criterion for car wash reclaimed water is 200 CFU 100 mL(-1). It is believed that the discussions on car wash wastewater reclamation criteria may assist institutions to create laws in Brazil and elsewhere.

  8. 27 CFR 19.328 - Wash water.

    Science.gov (United States)

    2010-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2010-04-01 2010-04-01 false Wash water. 19.328 Section... THE TREASURY LIQUORS DISTILLED SPIRITS PLANTS Production Chemical By-Products § 19.328 Wash water. Water used in washing chemicals to remove spirits therefrom may be run into a wash tank or a distilling...

  9. Tank 4 Characterization, Settling, And Washing Studies

    International Nuclear Information System (INIS)

    Bannochie, C.; Pareizs, J.; Click, D.; Zamecnik, J.

    2009-01-01

    A sample of PUREX sludge from Tank 4 was characterized, and subsequently combined with a Tank 51 sample (Tank 51-E1) received following Al dissolution, but prior to a supernate decant by the Tank Farm, to perform a settling and washing study to support Sludge Batch 6 preparation. The sludge source for the majority of the Tank 51-E1 sample is Tank 12 HM sludge. The Tank 51-E1 sample was decanted by SRNL prior to use in the settling and washing study. The Tank 4 sample was analyzed for chemical composition including noble metals. The characterization of the Tank 51-E1 sample, used here in combination with the Tank 4 sample, was reported previously. SRNL analyses on Tank 4 were requested by Liquid Waste Engineering (LWE) via Technical Task Request (TTR) HLE-TTR-2009-103. The sample preparation work is governed by Task Technical and Quality Assurance Plan (TTQAP), and analyses were controlled by an Analytical Study Plan and modifications received via customer communications. Additional scope included a request for a settling study of decanted Tank 51-E1 and a blend of decanted Tank 51-E1 and Tank 4, as well as a washing study to look into the fate of undissolved sulfur observed during the Tank 4 characterization. The chemistry of the Tank 4 sample was modeled with OLI Systems, Inc. StreamAnalyzer to determine the likelihood that sulfate could exist in this sample as insoluble Burkeite (2Na 2 SO 4 · Na 2 CO 3 ). The OLI model was also used to predict the composition of the blended tank materials for the washing study. The following conclusions were drawn from the Tank 4 analytical results reported here: (1) Any projected blend of Tank 4 and the current Tank 51 contents will produce a SB6 composition that is lower in Ca and U than the current SB5 composition being processed by DWPF. (2) Unwashed Tank 4 has a relatively large initial S concentration of 3.68 wt% on a total solids basis, and approximately 10% of the total S is present as an insoluble or undissolved form

  10. Process for washing electromagnetic filters

    International Nuclear Information System (INIS)

    Guittet, Maurice; Treille, Pierre.

    1980-01-01

    This process concerns the washing of an electro-magnetic filter used, inter alia, for filtering the drain-off waters of nuclear power station steam generators, by means of a washing water used in closed circuit and freed, after each cleaning, of the solids in suspension it contains, by settlement of these solids. This invention enables the volume of water to be evaporated to be divided by 50, thereby providing a solid assurance of better safety, apart from a very significant saving [fr

  11. Shp2-Dependent ERK Signaling Is Essential for Induction of Bergmann Glia and Foliation of the Cerebellum

    Science.gov (United States)

    Li, Kairong; Leung, Alan W.; Guo, Qiuxia; Yang, Wentian

    2014-01-01

    Folding of the cortex and the persistence of radial glia (RG)-like cells called Bergmann glia (BG) are hallmarks of the mammalian cerebellum. Similar to basal RG in the embryonic neocortex, BG maintain only basal processes and continuously express neural stem cell markers. Past studies had focused on the function of BG in granule cell migration and how granule cell progenitors (GCP) regulate cerebellar foliation. The molecular control of BG generation and its role in cerebellar foliation are less understood. Here, we have analyzed the function of the protein tyrosine phosphatase Shp2 in mice by deleting its gene Ptpn11 in the entire cerebellum or selectively in the GCP lineage. Deleting Ptpn11 in the entire cerebellum by En1-cre blocks transformation of RG into BG but preserves other major cerebellar cell types. In the absence of BG, inward invagination of GCP persists but is uncoupled from the folding of the Purkinje cell layer and the basement membrane, leading to disorganized lamination and an absence of cerebellar folia. In contrast, removing Ptpn11 in the GCP lineage by Atoh1-cre has no effect on cerebellar development, indicating that Shp2 is not cell autonomously required in GCP. Furthermore, we demonstrate that Ptpn11 interacts with Fgf8 and is essential for ERK activation in RG and nascent BG. Finally, expressing constitutively active MEK1 rescues BG formation and cerebellar foliation in Shp2-deficient cerebella. Our results demonstrate an essential role of Shp2 in BG specification via fibroblast growth factor/extracellular signal-regulated protein kinase signaling, and reveal a crucial function of BG in organizing cerebellar foliation. PMID:24431450

  12. Remediation of cadmium-contaminated paddy soils by washing with calcium chloride: Verification of on-site washing

    International Nuclear Information System (INIS)

    Makino, Tomoyuki; Kamiya, Takashi; Takano, Hiroyuki; Itou, Tadashi; Sekiya, Naoki; Sasaki, Kouta; Maejima, Yuji; Sugahara, Kazuo

    2007-01-01

    We developed a new, three-step soil-wash method to remediate Cd-contaminated paddy fields. The method comprises (1) chemically washing the field soil with a CaCl 2 solution; (2) washing the treated soil with water to eliminate residual Cd and CaCl 2 ; and (3) on-site treatment of wastewater using a portable wastewater treatment system. Cd concentrations in the treated water were below Japan's environmental quality standard (0.01 mg Cd L -1 ), and the removal of Cd from the exchangeable fraction was 55% and from the acid-soluble fraction 15%. While soil fertility properties were affected by the soil washing, adverse effects were not crucial and could be corrected. The washing had no affect on rice growth, and reduced the average Cd concentration in rice grains by about two-thirds compared to a control plot. These results confirmed the effectiveness of the soil-wash method in remediating Cd-contaminated paddy fields. - In situ soil washing in a paddy field using an on-site wastewater treatment system resulted in an effective decrease of Cd in soil and rice grains without affecting rice yield

  13. Abdominopelvic washings: A comprehensive review

    Directory of Open Access Journals (Sweden)

    Erika F Rodriguez

    2013-01-01

    Full Text Available Intraperitoneal spread may occur with gynecological epithelial neoplasms, as well as with non-gynecological malignancies, which may result in serosal involvement with or without concomitant effusion. Therefore, washings in patients with abdominopelvic tumors represent important specimens for cytologic examination. They are primarily utilized for staging ovarian cancers, although their role has decreased in staging of endometrial and cervical carcinoma. Abdominopelvic washings can be positive in a variety of pathologic conditions, including benign conditions, borderline neoplastic tumors, locally invasive tumors, or distant metastases. In a subset of cases, washings can be diagnostically challenging due to the presence of co-existing benign cells (e.g., mesothelial hyperplasia, endosalpingiosis, or endometriosis, lesions in which there is only minimal atypia (e.g., serous borderline tumors or scant atypical cells, and the rarity of specific tumor types (e.g., mesothelioma. Ancillary studies including immunocytochemistry and fluorescence in situ hybridization may be required in difficult cases to resolve the diagnosis. This article provides a comprehensive and contemporary review of abdominopelvic washings in the evaluation of gynecologic and non-gynecologic tumors, including primary peritoneal and mesothelial entities.

  14. WASH-1400: quantifying the uncertainties

    International Nuclear Information System (INIS)

    Erdmann, R.C.; Leverenz, F.L. Jr.; Lellouche, G.S.

    1981-01-01

    The purpose of this paper is to focus on the limitations of the WASH-1400 analysis in estimating the risk from light water reactors (LWRs). This assessment attempts to modify the quantification of the uncertainty in and estimate of risk as presented by the RSS (reactor safety study). 8 refs

  15. Laboratory testing in-tank sludge washing, summary letter report

    International Nuclear Information System (INIS)

    Norton, M.V.; Torres-Ayala, F.

    1994-09-01

    In-tank washing is being considered as a means of pretreating high-level radioactive waste sludges, such as neutralized current acid waste (NCAW) sludge. For this process, the contents of the tank will be allowed to settle, and the supernatant solution will be decanted and removed. A dilute sodium hydroxide/sodium nitrite wash solution will be added to the settled sludge and the tank contents will be mixed with a mixer pump system to facilitate washing of the sludge. After thorough mixing, the mixer pumps will be shut off and the solids will be allowed to re-settle. After settling, the supernatant solution will be withdrawn from the tank, and the wash cycle will be repeated several times with fresh wash solution. Core sample data of double shell tank 241-AZ-101 indicate that settling of NCAW solids may be very slow. A complicating factor is that strong thermal currents are expected to be generated from heat produced by radionuclides in the sludge layer at the bottom of the tank. Additionally, there are concerns that during the settling period (i.e., while mixing pumps and air-lift re-circulators are shut off), the radionuclides may heat the residual interstitial water in the sludge to the extent that violent steam discharges (steam bumping) could occur. Finally, there are concerns that during the washing steps sludge settling may be hindered as a result of the reduced ionic strength of the wash solution. To overcome the postulated reduced settling rates during the second and third washing steps, the use of flocculants is being considered. To address the above concerns and uncertainties associated with in-tank washing, PNL has conducted laboratory testing with simulant tank waste to investigate settling rates, steam bump potential, and the need for and use of flocculating agents

  16. Bacterial selection during the formation of early-stage aerobic granules in wastewater treatment systems operated under wash-out dynamics

    Directory of Open Access Journals (Sweden)

    David Gregory Weissbrodt

    2012-09-01

    Full Text Available Aerobic granular sludge is attractive for high-rate biological wastewater treatment. Biomass wash-out conditions stimulate the formation of aerobic granules. Deteriorated performances in biomass settling and nutrient removal during start-up have however often been reported. The effect of wash-out dynamics was investigated on bacterial selection, biomass settling behavior, and metabolic activities during the formation of early-stage granules from activated sludge of two wastewater treatment plants (WWTP over start-up periods of maximum 60 days. Five bubble-column sequencing batch reactors were operated with feast-famine regimes consisting of rapid pulse or slow anaerobic feeding followed by aerobic starvation. Slow-settling fluffy granules were formed when an insufficient superficial air velocity (SAV; 1.8 cm s-1 was applied, when the inoculation sludge was taken from a WWTP removing organic matter only, or when reactors were operated at 30°C. Fast-settling dense granules were obtained with 4.0 cm s-1 SAV, or when the inoculation sludge was taken from a WWTP removing all nutrients biologically. However, only carbon was aerobically removed during start-up. Fluffy granules and dense granules were displaying distinct predominant phylotypes, namely filamentous Burkholderiales affiliates and Zoogloea relatives, respectively. The latter were predominant in dense granules independently from the feeding regime. A combination of insufficient solid retention time and of leakage of acetate into the aeration phase during intensive biomass wash-out was the cause for the proliferation of Zoogloea spp. in dense granules, and for the deterioration of BNR performances. It is however not certain that Zoogloea-like organisms are essential in granule formation. Optimal operation conditions should be elucidated for maintaining a balance between organisms with granulation propensity and nutrient removing organisms in order to form granules with BNR activities in

  17. Bacterial Selection during the Formation of Early-Stage Aerobic Granules in Wastewater Treatment Systems Operated Under Wash-Out Dynamics.

    Science.gov (United States)

    Weissbrodt, David G; Lochmatter, Samuel; Ebrahimi, Sirous; Rossi, Pierre; Maillard, Julien; Holliger, Christof

    2012-01-01

    Aerobic granular sludge is attractive for high-rate biological wastewater treatment. Biomass wash-out conditions stimulate the formation of aerobic granules. Deteriorated performances in biomass settling and nutrient removal during start-up have however often been reported. The effect of wash-out dynamics was investigated on bacterial selection, biomass settling behavior, and metabolic activities during the formation of early-stage granules from activated sludge of two wastewater treatment plants (WWTP) over start-up periods of maximum 60 days. Five bubble-column sequencing batch reactors were operated with feast-famine regimes consisting of rapid pulse or slow anaerobic feeding followed by aerobic starvation. Slow-settling fluffy granules were formed when an insufficient superficial air velocity (SAV; 1.8 cm s(-1)) was applied, when the inoculation sludge was taken from a WWTP removing organic matter only, or when reactors were operated at 30°C. Fast-settling dense granules were obtained with 4.0 cm s(-1) SAV, or when the inoculation sludge was taken from a WWTP removing all nutrients biologically. However, only carbon was aerobically removed during start-up. Fluffy granules and dense granules were displaying distinct predominant phylotypes, namely filamentous Burkholderiales affiliates and Zoogloea relatives, respectively. The latter were predominant in dense granules independently from the feeding regime. A combination of insufficient solid retention time and of leakage of acetate into the aeration phase during intensive biomass wash-out was the cause for the proliferation of Zoogloea spp. in dense granules, and for the deterioration of BNR performances. It is however not certain that Zoogloea-like organisms are essential in granule formation. Optimal operation conditions should be elucidated for maintaining a balance between organisms with granulation propensity and nutrient removing organisms in order to form granules with BNR activities in short

  18. Sandstone-body and shale-body dimensions in a braided fluvial system: Salt wash sandstone member (Morrison formation), Garfield County, Utah

    Science.gov (United States)

    Robinson, J.W.; McCabea, P.J.

    1997-01-01

    Excellent three-dimensional exposures of the Upper Jurassic Salt Wash Sandstone Member of the Morrison Formation in the Henry Mountains area of southern Utah allow measurement of the thickness and width of fluvial sandstone and shale bodies from extensive photomosaics. The Salt Wash Sandstone Member is composed of fluvial channel fill, abandoned channel fill, and overbank/flood-plain strata that were deposited on a broad alluvial plain of low-sinuosity, sandy, braided streams flowing northeast. A hierarchy of sandstone and shale bodies in the Salt Wash Sandstone Member includes, in ascending order, trough cross-bedding, fining-upward units/mudstone intraclast conglomerates, singlestory sandstone bodies/basal conglomerate, abandoned channel fill, multistory sandstone bodies, and overbank/flood-plain heterolithic strata. Trough cross-beds have an average width:thickness ratio (W:T) of 8.5:1 in the lower interval of the Salt Wash Sandstone Member and 10.4:1 in the upper interval. Fining-upward units are 0.5-3.0 m thick and 3-11 m wide. Single-story sandstone bodies in the upper interval are wider and thicker than their counterparts in the lower interval, based on average W:T, linear regression analysis, and cumulative relative frequency graphs. Multistory sandstone bodies are composed of two to eight stories, range up to 30 m thick and over 1500 m wide (W:T > 50:1), and are also larger in the upper interval. Heterolithic units between sandstone bodies include abandoned channel fill (W:T = 33:1) and overbank/flood-plain deposits (W:T = 70:1). Understanding W:T ratios from the component parts of an ancient, sandy, braided stream deposit can be applied in several ways to similar strata in other basins; for example, to (1) determine the width of a unit when only the thickness is known, (2) create correlation guidelines and maximum correlation lengths, (3) aid in interpreting the controls on fluvial architecture, and (4) place additional constraints on input variables to

  19. Hydrodynamic calculation of a filter washing in liquids type used in containment venting systems; Calculo hidrodinamico de un filtro tipo lavado en liquidos usados en los sistemas de venteo de la contencion

    Energy Technology Data Exchange (ETDEWEB)

    Reyes G, A. A.; Sainz M, E.; Ortiz V, J., E-mail: alejandroantonioreyess@gmail.com [ININ, Carretera Mexico-Toluca s/n, 52750 Ocoyoacac, Estado de Mexico (Mexico)

    2015-09-15

    From the nuclear accident of Chernobyl, the European nuclear power plants have chosen to install filters on the venting pipes of the containment, whose function is to help to mitigate the consequences of a severe accident, by controlled depressurization of the containment passively through a filtered venting of the containment system. These systems are designed to relieve the internal pressure of the containment by means of the deliberate opening of pressure relief devices, either a valve or rupture disc during a severe accident and be channeled to the filter unit. In this paper the hydraulic response of a filter system of gases washing by liquid is evaluated, due to this information is necessary to estimate the effect that has the pressure increase of the contention on the discharge capacity of the venting pipes. By simulation of computational of fluid dynamics with the programs: CAELINUX-2014 and OpenFOAM, the hydrodynamic characteristics of the Multi Venturi System for gases washing from the containment, which could be included in the general model of the venting pipe, were obtained. Representative models of the Venturi tubes of each concentric area that forming the washing system were generated; and using parametric calculations the average mass flow rate established through each venturi, depending on its size and depth in which it is located inside the tank was estimated. Also, the pressure and mass flow rate required to activate each concentric area depending on the pressure and mass load from the containment were calculated, to estimate the maximum flow that is established through the filter. Finally, the velocity profiles and the characteristic pressure at which each area operates as well as the pressure drop of local and global discharge also were calculated. (Author)

  20. Effects of soap-water wash on human epidermal penetration.

    Science.gov (United States)

    Zhu, Hanjiang; Jung, Eui-Chang; Phuong, Christina; Hui, Xiaoying; Maibach, Howard

    2016-08-01

    Skin decontamination is a primary interventional method used to decrease dermal absorption of hazardous contaminants, including chemical warfare agents, pesticides and industrial pollutants. Soap and water wash, the most common and readily available decontamination system, may enhance percutaneous absorption through the "wash-in effect." To understand better the effect of soap-water wash on percutaneous penetration, and provide insight to improving skin decontamination methods, in vitro human epidermal penetration rates of four C(14) -labeled model chemicals (hydroquinone, clonidine, benzoic acid and paraoxon) were assayed using flow-through diffusion cells. Stratum corneum (SC) absorption rates of these chemicals at various hydration levels (0-295% of the dry SC weights) were determined and compared with the results of the epidermal penetration study to clarify the effect of SC hydration on skin permeability. Results showed accelerated penetration curves of benzoic acid and paraoxon after surface wash at 30 min postdosing. Thirty minutes after washing (60 min postdosing), penetration rates of hydroquinone and benzoic acid decreased due to reduced amounts of chemical on the skin surface and in the SC. At the end of the experiment (90 min postdosing), a soap-water wash resulted in lower hydroquinone penetration, greater paraoxon penetration and similar levels of benzoic acid and clonidine penetration compared to penetration levels in the non-wash groups. The observed wash-in effect agrees with the enhancement effect of SC hydration on the SC chemical absorption rate. These results suggest SC hydration derived from surface wash to be one cause of the wash-in effect. Further, the occurrence of a wash-in effect is dependent on chemical identity and elapsed time between exposure and onset of decontamination. By reducing chemical residue quantity on skin surface and in the SC reservoir, the soap-water wash may decrease the total quantity of chemical absorbed in the

  1. Calibration of redox potential in sperm wash media and evaluation of oxidation-reduction potential values in various assisted reproductive technology culture media using MiOXSYS system.

    Science.gov (United States)

    Panner Selvam, M K; Henkel, R; Sharma, R; Agarwal, A

    2018-03-01

    Oxidation-reduction potential describes the balance between the oxidants and antioxidants in fluids including semen. Various artificial culture media are used in andrology and IVF laboratories for sperm preparation and to support the development of fertilized oocytes under in vitro conditions. The composition and conditions of these media are vital for optimal functioning of the gametes. Currently, there are no data on the status of redox potential of sperm processing and assisted reproduction media. The purpose of this study was to compare the oxidation-reduction potential values of the different media and to calibrate the oxidation-reduction potential values of the sperm wash medium using oxidative stress inducer cumene hydroperoxide and antioxidant ascorbic acid. Redox potential was measured in 10 different media ranging from sperm wash media, freezing media and assisted reproductive technology one-step medium to sequential media. Oxidation-reduction potential values of the sequential culture medium and one-step culture medium were lower and significantly different (p value to identify the physiological range of oxidation-reduction potential that does not have any adverse effect on normal physiological sperm function. © 2017 American Society of Andrology and European Academy of Andrology.

  2. Soil washing for brine removal

    International Nuclear Information System (INIS)

    Ayyachamy, J.S.; Atalay, A.; Zaman, M.

    1992-01-01

    During the exploration for oil and thereafter, brine transfer lines get ruptured releasing the brine which contaminates the surrounding soil. The salinity level in brine is very high, sometimes approaching or exceeding that of sea water. Soils contaminated with brine are unproductive and unsuitable for plant growth. Several investigators have documented the pollution of surface water and groundwater due to brine disposal from oil and needed to clean up such sites. The objective of this study is to develop a soil washing technique that can be used to remove brine sites were collected and used in the study. This paper reports on results which indicate that soil washing using various surface active agents is effective in removing the brine

  3. Environmental diagnosis of the washing machine motor

    DEFF Research Database (Denmark)

    Erichsen, Hanne K. Linnet

    1997-01-01

    An environmental diagnosis of the washing machine focusing on the motor is performed. The goal of the diagnosis is to designate environmental focus points in the product. The LCA of the washing machine showed impact potentials from the life cycle of the product (see: LCA of a washing machine). Th...... up 2%, Manually disassembling and recycling of metals, Reuse of motor in a new washing machine, aluminium wire instead of copper wire in the motor....

  4. Design and construction of a live insulator washing system for transformers; Diseno y construccion de un sistema de lavado en vivo para los aisladores de transformadores

    Energy Technology Data Exchange (ETDEWEB)

    Lizama-Camara, Y.A. [Universidad Veracruzana, Veracruz (Mexico)]. E-mail: yahir_lizama@ieee.org; Mendieta-Antunez, J.A.; Blanco-Brisset, E. [Industrias IEM, Tlalnepantla, Estado de Mexico (Mexico)]. E-mail: unamanu@hotmail.com; Olivares Galvan, J.C.; Escarela-Perez, R. [Universidad Autonoma Metropolitana, Unidad Azcapotzalco, Mexico, D.F. (Mexico)]. E-mails: jolivare_1999@yahoo.com; r.escarela@ieee.org

    2012-04-15

    Through the electrical industry history there have been developments of different cleaning methods to avoid the insulators flashover s due to pollution. This paper describes the principal cleaning methods applicable to transformers insulators, emphasizing the high pressure fixed-type live insulator washing method, which was applied for cleaning the insulators of 900 MVA transformer bank of the Laguna Verde power plant localized at the state of Veracruz in Mexico. We propose a transformer insulator cleaning methodology, which identifies the main variables to take into account (the voltage level of the transformers, the pollution level of the insulators, determination of the optimal wash time, the amount of water, the optimal pressure of water jet, the maximum conductivity of the water and the wind velocity), reference values are given for these variables. In addition, we present an economic cost analysis when applying a method of this kind in an electric substation. [Spanish] A lo largo de la historia de la industria electrica se han desarrollado diferentes metodos de limpieza para evitar las fallas de los aisladores de los transformadores debido a la contaminacion. Este articulo describe los principales metodos de limpieza aplicables a los aisladores de transformadores, enfatizando el sistema de lavado en vivo tipo fijo con agua a alta presion, metodo que fue aplicado para realizar la limpieza de los aisladores en el banco de transformadores de 900 MVA de la central electrica Laguna Verde, ubicada en el estado de Veracruz, en Mexico. Se propone una metodologia para la limpieza de los aisladores de transformadores, donde se identifican las principales variables a tomar en cuenta (el nivel de tension de los transformadores, nivel de contaminacion de los aisladores, determinacion del tiempo optimo de lavado, cantidad de precipitacion de agua, presion optima del chorro de agua, maxima conductividad del agua y las velocidades de los vientos) y se dan valores de

  5. Prestart-up hydrogen peroxide solution washing of NPP unit with the RBMK-type reactor

    International Nuclear Information System (INIS)

    Gruzdev, N.I.; Man'kina, N.N.; Al'tshuller, M.A.

    1979-01-01

    Presented are the results of industrial hydrogen peroxide solution washing of condensating-feed system conducted on the second unit of the Kursk NPP. Duration of the washing constituted 8 hours. The hydrogen peroxide concentration during first 4 hours was 10-20 mg/kg at a flow rate of 260 m 2 /h, during the following 4 hours it constituted 2-5 mg/kg at a flow rate of 1000 m 3 /h. It is found out that prestart-up hydrogen peroxide washing of NPP power units with the RBMK-type reactor permits: to simplify essentially the technology and scheme of washing process; to reduce a flow rate of desalt washing water; to except environmental contamination with washing solutions and reagents being neutralized; to reduce the time of washing process; to reduce the time necessary for the achievement of reference water condition factors, and to increase the unit reliability and to improve a radiation situation

  6. Occupational Hydrofluoric Acid Injury from Car and Truck Washing--Washington State, 2001-2013.

    Science.gov (United States)

    Reeb-Whitaker, Carolyn K; Eckert, Carly M; Anderson, Naomi J; Bonauto, David K

    2015-08-21

    Exposure to hydrofluoric acid (HF) causes corrosive chemical burns and potentially fatal systemic toxicity. Car and truck wash cleaning products, rust removers, and aluminum brighteners often contain HF because it is efficient in breaking down roadway matter. The death of a truck wash worker from ingestion of an HF-based wash product and 48 occupational HF burn cases associated with car and truck washing in Washington State during 2001-2013 are summarized in this report. Among seven hospitalized workers, two required surgery, and all but one worker returned to the job. Among 48 injured workers, job titles were primarily auto detailer, car wash worker, truck wash worker, and truck driver. Because HF exposure can result in potentially severe health outcomes, efforts to identify less hazardous alternatives to HF-based industrial wash products are warranted.

  7. 100 Area soil washing bench-scale test procedures

    International Nuclear Information System (INIS)

    Freeman, H.D.; Gerber, M.A.; Mattigod, S.V.; Serne, R.J.

    1993-03-01

    This document describes methodologies and procedures for conducting soil washing treatability tests in accordance with the 100 Area Soil Washing Treatability Test Plan (DOE-RL 1992, Draft A). The objective of this treatability study is to evaluate the use of physical separation systems and chemical extraction methods as a means of separating chemically and radioactively contaminated soil fractions from uncontaminated soil fractions. These data will be primarily used for determining feasibility of the individual unit operations and defining the requirements for a system, or systems, for pilot-scale testing

  8. 100 Areas soil washing tradeoff study

    International Nuclear Information System (INIS)

    Belden, R.D.

    1995-11-01

    The complex nature of cost analysis and systems work demands a level of effort to ensure that decisions made support the best interests of all parties. This tradeoff study will act as a formal decision analysis method for the evaluation of many variables. The documentation of the decision rationale and system design is essential for successful planning and implementation of any system. The Hanford Site offers unique problems for economic analysis of remediation alternatives. The variations in the size of sites, geographic locations, and possible cleanup scenarios all add to the complexity of the tradeoff analysis. A thorough examination of all alternatives must be held to a level of detail appropriate to current regulatory and budgetary considerations. This study will compare the economics of two specific alternatives for remediation of soils at the Hanford Site. Remove and dispose is compared to remove, treat, and dispose. The treatment analyzed in this study is volume reduction through soil washing

  9. Centrifugation-free washing: A novel approach for removing immunoglobulin A from stored red blood cells.

    Science.gov (United States)

    Vörös, Eszter; Piety, Nathaniel Z; Strachan, Briony C; Lu, Madeleine; Shevkoplyas, Sergey S

    2018-08-01

    Washed red blood cells (RBCs) are indicated for immunoglobulin A (IgA) deficient recipients. Centrifugation-based cell processors commonly used by hospital blood banks cannot consistently reduce IgA below the recommended levels, hence double washing is frequently required. Here, we describe a prototype of a simple, portable, disposable system capable of washing stored RBCs without centrifugation, while reducing IgA below 0.05 mg/dL in a single run. Samples from RBC units (n = 8, leukoreduced, 4-6 weeks storage duration) were diluted with normal saline to a hematocrit of 10%, and then washed using either the prototype washing system, or via conventional centrifugation. The efficiency of the two washing methods was quantified and compared by measuring several key in vitro quality metrics. The prototype of the washing system was able to process stored RBCs at a rate of 300 mL/hour, producing a suspension of washed RBCs with 43 ± 3% hematocrit and 86 ± 7% cell recovery. Overall, the two washing methods performed similarly for most measured parameters, lowering the concentration of free hemoglobin by >4-fold and total free protein by >10-fold. Importantly, the new washing system reduced the IgA level to 0.02 ± 0.01 mg/mL, a concentration 5-fold lower than that produced by conventional centrifugation. This proof-of-concept study showed that centrifugation may be unnecessary for washing stored RBCs. A simple, disposable, centrifugation-free washing system could be particularly useful in smaller medical facilities and resource limited settings that may lack access to centrifugation-based cell processors. © 2017 Wiley Periodicals, Inc.

  10. Detecting wash trade in the financial market

    OpenAIRE

    Cao, Yi; Li, Yuhua; Coleman, Sonya; Belatreche, Ammar; McGinnity, T. M.

    2014-01-01

    Wash trade refers to the activities of traders who utilise deliberately designed collusive transactions to increase the trading volumes for creating active market impression. Wash trade can be damaging to the proper functioning and integrity of capital markets. Existing work focuses on collusive clique detections based on certain assumptions of trading behaviours. Effective approaches for analysing and detecting wash trade in a real-life market have yet to be developed. T...

  11. EFRT M-12 Issue Resolution: Solids Washing

    Energy Technology Data Exchange (ETDEWEB)

    Baldwin, David L.; Schonewill, Philip P.; Toth, James J.; Huckaby, James L.; Eslinger, Paul W.; Hanson, Brady D.; Kurath, Dean E.; Minette, Michael J.

    2009-08-14

    Pacific Northwest National Laboratory (PNNL) has been tasked by Bechtel National Inc. (BNI) on the River Protection Project-Hanford Tank Waste Treatment and Immobilization Plant (RPP-WTP) project to perform research and development activities to resolve technical issues identified for the Pretreatment Facility (PTF). The Pretreatment Engineering Platform (PEP) was designed, constructed, and operated as part of a plan to respond to issue M12, “Undemonstrated Leaching Processes.” The PEP is a 1/4.5-scale test platform designed to simulate the WTP pretreatment caustic leaching, oxidative leaching, ultrafiltration solids concentration, and slurry washing processes. The PEP replicates the WTP leaching processes using prototypic equipment and control strategies. Two operating scenarios were evaluated for the ultrafiltration process (UFP) and leaching operations. The first scenario has caustic leaching performed in the UFP-VSL-T01A/B ultrafiltration feed vessels, identified as Integrated Test A. The second scenario has caustic leaching conducted in the UFP-VSL-T02A ultrafiltration feed preparation vessel, identified as Integrated Test B. Washing operations in PEP Integrated Tests A and B were conducted successfully as per the approved run sheets. However, various minor instrumental problems occurred, and some of the process conditions specified in the run sheet were not met during the wash operations, such as filter-loop flow-rate targets not being met. Five analytes were selected based on full solubility and monitored in the post-caustic-leach wash as successful indicators of washing efficiency. These were aluminum, sulfate, nitrate, nitrite, and free hydroxide. Other analytes, including sodium, oxalate, phosphate, and total dissolved solids, showed indications of changing solubility; therefore, they were unsuitable for monitoring washing efficiency. In the post-oxidative-leach wash, two analytes with full solubility were selected as suitable indicators of washing

  12. Optimal Portfolio Choice with Wash Sale Constraints

    DEFF Research Database (Denmark)

    Astrup Jensen, Bjarne; Marekwica, Marcel

    2011-01-01

    We analytically solve the portfolio choice problem in the presence of wash sale constraints in a two-period model with one risky asset. Our results show that wash sale constraints can heavily affect portfolio choice of investors with unrealized losses. The trading behavior of such investors...

  13. Alternative Antimicrobial Commercial Egg Washing Procedures.

    Science.gov (United States)

    Hudson, Lauren K; Harrison, Mark A; Berrang, Mark E; Jones, Deana R

    2016-07-01

    Commercial table eggs are washed prior to packaging. Standard wash procedures use an alkaline pH and warm water. If a cool water method could be developed that would still provide a microbiologically safe egg, the industry may save energy costs associated with water heating. Four wash procedures were evaluated for Salmonella reduction: pH 11 at 48.9°C (industry standard), pH 11 at ambient temperature (∼20°C), pH 6 at 48.9°C, and pH 6 at ambient temperature. Alkaline washes contained potassium hydroxide-based detergent, while pH 6 washes contained approximately 200 ppm of chlorine and a proprietary chlorine stabilizer (T-128). When eggs were inoculated by immersion in a cell suspension of Salmonella Enteritidis and Salmonella Typhimurium, all treatments resulted in a slight and similar reduction of Salmonella numbers (approximately 0.77 log CFU/ml of shell emulsion reduction). When eggs were inoculated by droplet on the shell surface, Salmonella counts were reduced by approximately 5 log CFU when washed with chlorine plus the chlorine stabilizer at both temperatures and with the alkaline wash at the high temperature. The reductions in Salmonella by these treatments were not significantly (P > 0.05) different from each other but were significantly (P pH 11 warm water wash and may be a viable option to reduce cost, increase shelf life, and slow pathogen growth in and on shell eggs.

  14. Ink and Wash Painting for Children with Visual Impairment

    Science.gov (United States)

    Shih, Chih-Ming; Chao, Hsin-Yi

    2010-01-01

    Five children with visual impairments received instruction in drawing, using ink and wash painting and calligraphy techniques. A special system developed by a blind Taiwanese Chinese calligrapher, Tsann-Cherng Liaw, was used to help the children orient and refine their work. Children's performance on simple drawing tasks was compared before and…

  15. Contaminant resorption during soil washing

    International Nuclear Information System (INIS)

    Gombert, D.

    1993-01-01

    To evaluate the applicability of soil washing to a specific site requires some basic research in how contaminants are bound. Much can be learned from sequential extraction methodology based on micronutrient bioavailability studies wherein the soil matrix is chemically dissected to selectively remove particular fixation mechanisms independently. This procedure uses a series of progressively more aggressive solvents to dissolve the principle phases that make up a soil, however, the published studies do not appear to consider the potential for a contaminant released from one type of site to resorb on another site during an extraction. This physical model assumes no ion exchange or adsorption at sites either previously occupied by other ions, or exposed by the dissolution. Therefore, to make engineering use of the sequential extraction data, the release of contamination must be evaluated relative to the effects of resorption. Time release studies were conducted to determine the optimum duration for extraction to maximize complete destruction of the target matrix fraction while minimizing contaminant resorption. Tests with and without a potassium brine present to inhibit cesium resorption indicated extraction efficiency could be enhanced by as much as a factor of ten using the brine

  16. Characterization of wastewaters from vehicle washing companies and environmental impacts

    Directory of Open Access Journals (Sweden)

    Valderi Duarte Leite

    2011-12-01

    Full Text Available The car wash business has developed rapidly in recent years due to the increased number of cars, thus, it can cause serious environmental problems considering its potential source of pollution. The aim of this study was to characterize the wastewater from car washing companies in the city of Campina Grande, in Paraiba state, and to analyze the environmental impacts generated. A survey was conducted from November 2009 to July 2010. The first step we present a survey of car wash businesses in the city, and identified 20 licensed companies in which we evaluated the number of vehicles washed per week, the existence of a system of pre-treatment of wastewater generated and infrastructure that would allow the realization of the collection of samples of the effluent, the second step was carried out chemical and physical characterization of wastewater from five 20 companies surveyed in the previous step, and third stage were measured pollution loads of wastewater from washing of vehicles in the city, from the results obtained in previous steps. The characterization parameters were analyzed: oil and grease, COD, heavy metals, TS, TSS, turbidity, TKN, total P, pH and color. The results demonstrated that the wastewater from the car wash establishments shows high concentrations of organic matter, oils and grease, heavy metals and solids, and as such did not conform with the specific environmental legislation. Evaluation of pollutant loads demonstrated that if releases without proper treatment, it can cause serious environmental problems. It is therefore essential that these establishments are properly monitored.

  17. Late washing filter cleaning cycle demonstration

    International Nuclear Information System (INIS)

    Meyer, M.L.; McCabe, D.J.

    1992-01-01

    The DWPF Late Washing Facility will filter cesium and potassium tetraphenyl borate (TPB) solids using a Mott sintered metal filter, identical to the filter now used in the In-tank Precipitation Facility. The purpose of the late wash step is primarily to remove the nitrite salts from the slurry prior to delivery to DWPF. Periodic chemical cleaning of the filter will be required, presumably after each batch although the actual required frequency could not be determined on the lab-scale. Minimization of chemical cleaning solution volumes is key to maximizing the attainment of the Late Wash facility. This report summarizes work completed in experiments designed to identify minimum cleaning solution requirements

  18. Nitric acid flowsheet with late wash PHA testing

    International Nuclear Information System (INIS)

    Zamecnik, J.R.

    1993-01-01

    This Task Technical Plan outlines the activities to be conducted in the Integrated DWPF Melter System (IDMS) in ongoing support of the Defense Waste Processing Facility (DWPF) Chemical Process Cell (CPC) utilizing the Nitric Acid Flowsheet in the Sludge Receipt and Adjustment Tank (SRAT) and Precipitate Hydrolysis Aqueous (PHA) produced by the Late Wash Flowsheet. The IDMS facility is to be operated over a series of runs (2 to 4) using the Nitric Acid Flowsheet. The PHA will be produced with the Late Wash Flowsheet in the Precipitate Hydrolysis Experimental Facility (PHEF). All operating conditions shall simulate the expected DWPF operating conditions as closely as possible. The task objectives are to perform at least two IDMS runs with as many operating conditions as possible at nominal DWPF conditions. The major purposes of these runs are twofold: verify that the combined Late Wash and Nitric Acid flowsheets produce glass of acceptable quality without additional changes to process equipment, and determine the reproducibility of data from run to run. These runs at nominal conditions will be compared to previous runs made with PHA produced from the Late Wash flowsheet and with the Nitric Acid flowsheet in the SRAT (Purex 4 and Purex 5)

  19. Reliability of piping system components. Volume 2: PSA LOCA data base. Review of methods for LOCA evaluation since the WASH-1400

    Energy Technology Data Exchange (ETDEWEB)

    Nyman, R.; Erixon, S. [Swedish Nuclear Power Inspectorate, Stockholm (Sweden); Tomic, B. [ENCONET Consulting GmbH, Vienna (Austria); Lydell, B. [RSA Technologies, Visat, CA (United States)

    1996-09-01

    The Swedish Nuclear Power Inspectorate has undertaken a project to establish a comprehensive passive components database, validate failure rate parameter estimates and model framework for enhancement of integrating passive components failures in existing PSAs. Phase 1 of the project produced a relational database on worldwide piping system failure. Approx. 2300 failure events allowed for data exploration in Phase 2 to develop a sound basis for PSA treatment of piping system failure. In addition, a comprehensive review of the current consideration of LOCA in PSA and of all available literature in this area was undertaken. This report is devoted to identification of treatment of LOCA in PSAs. The report contains a detailed review of many programs and dozens of specific PSA studies for different reactor types. This collection and analysis of information together with information for the relational database was used to develop a matrix approach on contribution to LOCA events from different components which are part of the reactor coolant system pressure boundary. The overall conclusion of the work is that although there are some further developments in this area, there is still no significant enhancement of ways how LOCA are considered in PSAs as compared to the mid 70s, only selected studies attempted to address LOCAs in a more comprehensive way. Later phases of this project are expected to contribute to enhancement of treatment of LOCA events in PSA studies. 54 refs, 25 tabs.

  20. Reliability of piping system components. Volume 2: PSA LOCA data base. Review of methods for LOCA evaluation since the WASH-1400

    International Nuclear Information System (INIS)

    Nyman, R.; Erixon, S.; Tomic, B.; Lydell, B.

    1996-09-01

    The Swedish Nuclear Power Inspectorate has undertaken a project to establish a comprehensive passive components database, validate failure rate parameter estimates and model framework for enhancement of integrating passive components failures in existing PSAs. Phase 1 of the project produced a relational database on worldwide piping system failure. Approx. 2300 failure events allowed for data exploration in Phase 2 to develop a sound basis for PSA treatment of piping system failure. In addition, a comprehensive review of the current consideration of LOCA in PSA and of all available literature in this area was undertaken. This report is devoted to identification of treatment of LOCA in PSAs. The report contains a detailed review of many programs and dozens of specific PSA studies for different reactor types. This collection and analysis of information together with information for the relational database was used to develop a matrix approach on contribution to LOCA events from different components which are part of the reactor coolant system pressure boundary. The overall conclusion of the work is that although there are some further developments in this area, there is still no significant enhancement of ways how LOCA are considered in PSAs as compared to the mid 70s, only selected studies attempted to address LOCAs in a more comprehensive way. Later phases of this project are expected to contribute to enhancement of treatment of LOCA events in PSA studies. 54 refs, 25 tabs

  1. UO2 production process with methanol washing

    International Nuclear Information System (INIS)

    Sondermann, T.

    1978-01-01

    The invention refers to a process for the recovery of methanol used for washing the ammonium uranyl carbonate obtained during UO 2 production. The methanol contains about 50% H 2 O, about 10% (NH 4 ) 2 CO 3 , and is radioactive. According to the invention the methanol is purified at reduced pressure in a distillation unit and then led back to the washing unit. (UWI) 891 HP/UWI 892 MBE [de

  2. Improving understanding of the underlying physical process of sediment wash-off from urban road surfaces

    Science.gov (United States)

    Muthusamy, Manoranjan; Tait, Simon; Schellart, Alma; Beg, Md Nazmul Azim; Carvalho, Rita F.; de Lima, João L. M. P.

    2018-02-01

    Among the urban aquatic pollutants, the most common is sediment which also acts as a transport medium for many contaminants. Hence there is an increasing interest in being able to better predict the sediment wash-off from urban surfaces. The exponential wash-off model is the most widely used method to predict the sediment wash-off. Although a number of studies proposed various modifications to the original exponential wash-off equation, these studies mostly looked into one parameter in isolation thereby ignoring the interactions between the parameters corresponding to rainfall, catchment and sediment characteristics. Hence in this study we aim (a) to investigate the effect of rainfall intensity, surface slope and initial load on wash-off load in an integrated and systematic way and (b) to subsequently improve the exponential wash-off equation focusing on the effect of the aforementioned three parameters. A series of laboratory experiments were carried out in a full-scale setup, comprising of a rainfall simulator, a 1 m2 bituminous road surface, and a continuous wash-off measuring system. Five rainfall intensities ranging from 33 to 155 mm/h, four slopes ranging from 2 to 16% and three initial loads ranging from 50 to 200 g/m2 were selected based on values obtained from the literature. Fine sediment with a size range of 300-600 μm was used for all of the tests. Each test was carried out for one hour with at least 9 wash-off samples per test collected. Mass balance checks were carried out for all the tests as a quality control measure to make sure that there is no significant loss of sand during the tests. Results show that the washed off sediment load at any given time is proportional to initial load for a given combination of rainfall intensity and surface slope. This indicates the importance of dedicated modelling of build-up so as to subsequently predict wash-off load. It was also observed that the maximum fraction that is washed off from the surface increases

  3. Gas turbine cleaning upgrade (compressor wash)

    Energy Technology Data Exchange (ETDEWEB)

    Asplund, P. [Gas Turbine Efficiency, Jarfalla (Sweden)

    1998-12-31

    The influence of gas turbine degradation on operating costs is high. Gas turbine cleaning is one of many actions taken for power recovery and is to consider as preventive maintenance. It is generally performed within the industrial field and occasionally within the aero sector. In order to meet the gas turbine development win high blade loads and ever-increasing temperatures, together with emission Aces and environmental regulations, more efficient and careful cleaning methods are needed. Following a survey about potentials for cost reduction in gas turbine operation a new man-hour and water saving cleaning method has been evaluated for a standard process. Compared with traditional cleaning methods, the new method is water,- cost,- weight and space saving due to a new washing technique. Traditional methods are based on using different nozzles for ON and OFF-line cleaning, which rise the demand for complicated systems. In the new method the same nozzle installation, same liquid flow and pressure is used for both ON and OFF-line cleaning. This gives a cost reduction of appr. 20.000 - 30.000 USD per gas turbine depending on installation and size. Evaluation of the new method shows significantly improved ON -line cleaning performance and thus OFF -line cleaning is required only during scheduled stops. (orig.) 10 refs.

  4. Gas turbine cleaning upgrade (compressor wash)

    Energy Technology Data Exchange (ETDEWEB)

    Asplund, P [Gas Turbine Efficiency, Jarfalla (Sweden)

    1999-12-31

    The influence of gas turbine degradation on operating costs is high. Gas turbine cleaning is one of many actions taken for power recovery and is to consider as preventive maintenance. It is generally performed within the industrial field and occasionally within the aero sector. In order to meet the gas turbine development win high blade loads and ever-increasing temperatures, together with emission Aces and environmental regulations, more efficient and careful cleaning methods are needed. Following a survey about potentials for cost reduction in gas turbine operation a new man-hour and water saving cleaning method has been evaluated for a standard process. Compared with traditional cleaning methods, the new method is water,- cost,- weight and space saving due to a new washing technique. Traditional methods are based on using different nozzles for ON and OFF-line cleaning, which rise the demand for complicated systems. In the new method the same nozzle installation, same liquid flow and pressure is used for both ON and OFF-line cleaning. This gives a cost reduction of appr. 20.000 - 30.000 USD per gas turbine depending on installation and size. Evaluation of the new method shows significantly improved ON -line cleaning performance and thus OFF -line cleaning is required only during scheduled stops. (orig.) 10 refs.

  5. Hand washing promotion for preventing diarrhoea

    Science.gov (United States)

    Ejemot-Nwadiaro, Regina I; Ehiri, John E; Arikpo, Dachi; Meremikwu, Martin M; Critchley, Julia A

    2015-01-01

    Background Diarrhoea accounts for 1.8 million deaths in children in low- and middle-income countries (LMICs). One of the identified strategies to prevent diarrhoea is hand washing. Objectives To assess the effects of hand washing promotion interventions on diarrhoeal episodes in children and adults. Search methods We searched the Cochrane Infectious Diseases Group Specialized Register (27 May 2015); CENTRAL (published in the Cochrane Library 2015, Issue 5); MEDLINE (1966 to 27 May 2015); EMBASE (1974 to 27 May 2015); LILACS (1982 to 27 May 2015); PsycINFO (1967 to 27 May 2015); Science Citation Index and Social Science Citation Index (1981 to 27 May 2015); ERIC (1966 to 27 May 2015); SPECTR (2000 to 27 May 2015); Bibliomap (1990 to 27 May 2015); RoRe, The Grey Literature (2002 to 27 May 2015); World Health Organization (WHO) International Clinical Trial Registry Platform (ICTRP), metaRegister of Controlled Trials (mRCT), and reference lists of articles up to 27 May 2015. We also contacted researchers and organizations in the field. Selection criteria Individually randomized controlled trials (RCTs) and cluster-RCTs that compared the effects of hand washing interventions on diarrhoea episodes in children and adults with no intervention. Data collection and analysis Three review authors independently assessed trial eligibility, extracted data, and assessed risk of bias. We stratified the analyses for child day-care centres or schools, community, and hospital-based settings. Where appropriate, incidence rate ratios (IRR) were pooled using the generic inverse variance method and random-effects model with 95% confidence intervals (CIs). We used the GRADE approach to assess the quality of evidence. Main results We included 22 RCTs: 12 trials from child day-care centres or schools in mainly high-income countries (54,006 participants), nine community-based trials in LMICs (15,303 participants), and one hospital-based trial among people with acquired immune deficiency

  6. Soil washing: From characterization to implementation

    International Nuclear Information System (INIS)

    Corden, F.L.; Groenendijk, E.

    1995-01-01

    Only recently has soil washing begun to be applied to remediation of contaminated soils in the US. The experience gained during full-scale and large pilot-scale projects points to the importance of soil and site characterization in correctly evaluating the applicability of soil washing to a site and determining accurate cost estimates for its implementation. This paper will discuss actual case studies of various treatability and pilot study approaches that led to successful evaluation and implementation of soil washing remedies. Soil washing is applicable to a broad variety of chemical contaminants. Target contaminants include metals, radionuclides, pesticides, polychlorinated biphenyls, polynuclear aromatic hydrocarbons and petroleum hydrocarbons, as well as combinations of these contaminants. Because the contaminants noted above are deposited in the soils in a variety of forms, the unit operations necessary to treat the soil vary. It is the diversity of the available treatment alternatives, and the ability to use the units in a variety of process flow configurations that result in a very broad definition of soil washing

  7. Washing of waste prior to landfilling.

    Science.gov (United States)

    Cossu, Raffaello; Lai, Tiziana

    2012-05-01

    The main impact produced by landfills is represented by the release of leachate emissions. Waste washing treatment has been investigated to evaluate its efficiency in reducing the waste leaching fraction prior to landfilling. The results of laboratory-scale washing tests applied to several significant residues from integrated management of solid waste are presented in this study, specifically: non-recyclable plastics from source separation, mechanical-biological treated municipal solid waste and a special waste, automotive shredded residues. Results obtained demonstrate that washing treatment contributes towards combating the environmental impacts of raw wastes. Accordingly, a leachate production model was applied, leading to the consideration that the concentrations of chemical oxygen demand (COD) and total Kjeldahl nitrogen (TKN), parameters of fundamental importance in the characterization of landfill leachate, from a landfill containing washed wastes, are comparable to those that would only be reached between 90 and 220years later in the presence of raw wastes. The findings obtained demonstrated that washing of waste may represent an effective means of reducing the leachable fraction resulting in a consequent decrease in landfill emissions. Further studies on pilot scale are needed to assess the potential for full-scale application of this treatment. Copyright © 2012 Elsevier Ltd. All rights reserved.

  8. Bacteriological aspects of hand washing: A key for health promotion and infections control

    Directory of Open Access Journals (Sweden)

    Ramezan Ali Ataee

    2017-01-01

    Full Text Available The aim of this review is to show the historical aspects of hands washing for healthy life and explains how can reduce the transmission of community-acquired infectious agents by healthcare workers and patients. This review article is prepared based on available database. The key words used were hands washing, risk assessment, hands hygiene, bacterial flora, contamination, infection, nosocomial, tap water, sanitizer, bacterial resistance, hands bacterial flora, washing methods, antiseptics, healthcare workers, healthcare personnel, from PubMed, ScienceDirect, Embase, Scopus, Web of Sciences, and Google Scholar. Data were descriptively analyzed. The insistence on hand washing has a history of 1400 years. The research results indicate that the bacteria released from the female washed hands in wet and dry condition was lower than from the male′s hands with a significance level (3 CFU vs. 8 CFU; confidence interval 95%, P ≤ 0.001. The valuable results of the study indicated that released amount of bacterial flora from wet hands is more than 10 times in compared to dry hands. In addition, established monitoring systems for washing hands before and after patient′s manipulation as well as after toilet were dominant indices to prevent the transfer of infectious agents to the patients. Increasing awareness and belief of the healthcare workers have shown an important role by about 30% reduction in the transfection. Hand washing could reduce the episodes of transmission of infectious agents in both community and healthcare settings. However, hand washing is an important key factor to prevent transmission of infectious agents to patients. There is no standard method for measuring compliance. Thus, permanent monitoring of hand washing to reduce the transmission of infections is crucial. Finally, the personnel must believe that hand washing is an inevitable approach to infection control.

  9. 30 CFR 206.459 - Allocation of washed coal.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 2 2010-07-01 2010-07-01 false Allocation of washed coal. 206.459 Section 206... MANAGEMENT PRODUCT VALUATION Indian Coal § 206.459 Allocation of washed coal. (a) When coal is subjected to washing, the washed coal must be allocated to the leases from which it was extracted. (b) When the net...

  10. 30 CFR 206.260 - Allocation of washed coal.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 2 2010-07-01 2010-07-01 false Allocation of washed coal. 206.260 Section 206... MANAGEMENT PRODUCT VALUATION Federal Coal § 206.260 Allocation of washed coal. (a) When coal is subjected to washing, the washed coal must be allocated to the leases from which it was extracted. (b) When the net...

  11. Ultrafiltration to reuse laundering wash water

    DEFF Research Database (Denmark)

    Giagnorio, Mattia; Søtoft, Lene Fjerbæk; Tiraferri, Alberto

    2017-01-01

    Laundering industry consumes and discharges large amounts of water and surfactants, and the demand of surface active agents used for washing is increasing worldwide. Some of these substances are considered contaminants of emerging concern, as they persist in the environment. This work aimed...... at evaluating the feasibility of ultrafiltration as a method to treat the wash wastewater and possibly reuse the surfactant-rich permeate stream in laundry facilities. In particular, evaluation of surfactant recovery was performed through analysis of the permeate flux and properties obtained through polymeric...... and ceramic membranes. Wash water samples were collected at an industrial laundering facility for hospital linen and filtered through different ultrafiltration membranes with varying molecular weight cut-off. The critical micelle concentration of the detergent was quantified, and capillarity measurements were...

  12. Plutonium recovery from carbonate wash solutions

    International Nuclear Information System (INIS)

    Gray, J.H.; Reif, D.J.; Chostner, D.F.; Holcomb, H.P.

    1991-01-01

    540Periodically higher than expected levels of plutonium are found in carbonate solutions used to wash second plutonium cycle solvent. The recent accumulation of plutonium in carbonate wash solutions has led to studies to determine the cause of that plutonium accumulation, to evaluate the quality of all canyon solvents, and to develop additional criteria needed to establish when solvent quality is acceptable. Solvent from three canyon solvent extraction cycles was used to evaluate technology required to measure tributyl phosphate (TBP) degradation products and was used to evaluate solvent quality criteria during the development of plutonium recovery processes. 1 fig

  13. Use of green washing fluids in a washing process for dioxin contaminated soils

    Directory of Open Access Journals (Sweden)

    Siwalee Yotapukdee

    2017-09-01

    Full Text Available High levels of dioxin contamination in soil have significant environmental challenges. Soil washing is a successful remediation process that is primarily used to treat coarse soils. Several literature studies have used various kinds of chemical washing liquids to remove dioxins from soils, though there are secondary environmental effects. This study intends to develop environmentally friendly soil washing methods that are effective in dioxin removal at an acceptable cost. Sugarcane wine, compost leachate, and ground fish broth were chosen as potential washing liquids. Each washing liquid was analyzed to determine its content of semivolatile organic compounds (SVOCs and volatile organic compounds (VOCs. These compounds are related to their bio-surfactant content. Several of the identified compounds had properties to help remove dioxins from contaminated soil. In the experiments, high removal efficiencies were observed, up to 70%~95% after five to six washes. Although effective removal was observed, a significant amount of wastewater was produced and the problems were not completely resolved. Thus, the optimal washing conditions are necessary to minimize the overall costs, while improving the process effectiveness. Moreover, an appropriate treatment method is required for wastewater containing dioxins.

  14. SOIL-WASHING TECHNOLOGY AND PRACTICE

    Science.gov (United States)

    Soil washing in the United States has been studied and evaluated with increasing thoroughness during the last 15 to 20 years. It is now entering a phase of actual use and acceptance as its applicability and economics become clearer. This paper reviews the principles behind soil...

  15. Environmental control during steam boiler washing

    Energy Technology Data Exchange (ETDEWEB)

    Guimaraes, Marcio A.B.; Abreu Pereira, Vera L. de [Companhia Petroquimica do Nordeste (COPENE), Camacari, BA (Brazil). Div. de Engenharia Ambiental; Ringler, Ulrich E.S. [PROMON Engenharia Ltda., Salvador, BA (Brazil)

    1993-12-31

    The washing and chemical cleaning of boilers, activities of a high polluting potential, are responsible for the generation of wastewater of high contents of heavy metals, suspended solids and chemical oxygen demand (COD). This paper describes the actions carried out by COPENE - Petroquimica do Nordeste S/A - in order to reduce this problem. (author). 10 refs., 3 figs., 2 tabs.

  16. Environmental control during steam boiler washing

    Energy Technology Data Exchange (ETDEWEB)

    Guimaraes, Marcio A.B.; Abreu Pereira, Vera L. de [Companhia Petroquimica do Nordeste (COPENE), Camacari, BA (Brazil). Div. de Engenharia Ambiental; Ringler, Ulrich E.S. [PROMON Engenharia Ltda., Salvador, BA (Brazil)

    1994-12-31

    The washing and chemical cleaning of boilers, activities of a high polluting potential, are responsible for the generation of wastewater of high contents of heavy metals, suspended solids and chemical oxygen demand (COD). This paper describes the actions carried out by COPENE - Petroquimica do Nordeste S/A - in order to reduce this problem. (author). 10 refs., 3 figs., 2 tabs.

  17. What Happens at a Car Wash?

    Science.gov (United States)

    Gallick, Barbara; Lee, Lisa

    2010-01-01

    A class of 3- to 5-year-old children in a child care center in the midwestern United States chose to study a car wash as a group project. This article discusses how the project evolved, describes the three phases of the project, and provides the teachers' reflections on the project. Photos taken during the project and children's sketches are…

  18. A method for treating clayless wash fluids

    Energy Technology Data Exchange (ETDEWEB)

    Deykalo, T A; Dzhumagaliyev, T N; Skvortsov, D S

    1980-02-18

    To increase the heat and salt resistance of a wash fluid, monoethanolamine processed waste of licorice production - grist in a volume of 5-8% by weight, is introduced into it as the disperse phase. The processing of the grist is conducted for 1-2 hours at 20-100/sup 0/C and the volume of the monoethanolamine is 0.05-0.1% by weight. The properties of the washing fluids treated by the grist with the introduction of 20% CaC1/sub 2/ into them were not deteriorated, while complete coagulation was achieved with its introduction into washing fluids on the basis of KMTs. Grist washing liquids do not deteriorate their own properties to a temperature of 200/sup 0/C, do not cause equipment corrosion, are inert to swelling clay rocks and with the introduction of KMTs at a temperature above 130-140/sup 0/C cause insignificant destruction of the reagent which is accompanied by a change in the color of the solutions and a drop in the degree of polymerization and viscosity.

  19. Hand washing promotion for preventing diarrhoea.

    Science.gov (United States)

    Ejemot-Nwadiaro, Regina I; Ehiri, John E; Arikpo, Dachi; Meremikwu, Martin M; Critchley, Julia A

    2015-09-03

    Diarrhoea accounts for 1.8 million deaths in children in low- and middle-income countries (LMICs). One of the identified strategies to prevent diarrhoea is hand washing. To assess the effects of hand washing promotion interventions on diarrhoeal episodes in children and adults. We searched the Cochrane Infectious Diseases Group Specialized Register (27 May 2015); CENTRAL (published in the Cochrane Library 2015, Issue 5); MEDLINE (1966 to 27 May 2015); EMBASE (1974 to 27 May 2015); LILACS (1982 to 27 May 2015); PsycINFO (1967 to 27 May 2015); Science Citation Index and Social Science Citation Index (1981 to 27 May 2015); ERIC (1966 to 27 May 2015); SPECTR (2000 to 27 May 2015); Bibliomap (1990 to 27 May 2015); RoRe, The Grey Literature (2002 to 27 May 2015); World Health Organization (WHO) International Clinical Trial Registry Platform (ICTRP), metaRegister of Controlled Trials (mRCT), and reference lists of articles up to 27 May 2015. We also contacted researchers and organizations in the field. Individually randomized controlled trials (RCTs) and cluster-RCTs that compared the effects of hand washing interventions on diarrhoea episodes in children and adults with no intervention. Three review authors independently assessed trial eligibility, extracted data, and assessed risk of bias. We stratified the analyses for child day-care centres or schools, community, and hospital-based settings. Where appropriate, incidence rate ratios (IRR) were pooled using the generic inverse variance method and random-effects model with 95% confidence intervals (CIs). We used the GRADE approach to assess the quality of evidence. We included 22 RCTs: 12 trials from child day-care centres or schools in mainly high-income countries (54,006 participants), nine community-based trials in LMICs (15,303 participants), and one hospital-based trial among people with acquired immune deficiency syndrome (AIDS) (148 participants).Hand washing promotion (education activities, sometimes with

  20. Comparison of the laboratory standard washing using CIPAC washing agent and the domestic washing on three recommended types of long-lasting insecticidal mosquito nets.

    Science.gov (United States)

    Ouattara, Jean Pierre Nabléni; Louwagie, Johanna; Pigeon, Olivier; Spanoghe, Pieter

    2013-01-01

    One of the best ways to prevent malaria is the use of insecticide-treated bed nets. Manufacturers pursue easier, safer and more efficient nets. Hence, many studies on the efficacy and wash resistance using World Health Organization standards have been reported. The commonly used detergent is "Savon de Marseille", because it closely resembles actually used soaps. At the 54(th) Collaborative International Pesticides Analytical Council (CIPAC) Technical Meeting in 2010, it was suggested to replace it by a standardized "CIPAC washing agent". The aim of this study was to investigate the difference between a laboratory hand washing simulation using the CIPAC washing agent (method-1) and a domestic washing (method-2) on different bed nets, as well as the effect of the drying process on the release of active ingredient. Interceptor®, Permanet®2.0 and Netprotect® nets were used in three treatments, each repeated 20 times. The first treatment included method-1 washing and indoor drying. The second treatment included method-2 washing and indoor drying. The third treatment used method-2 washing and UV-drying. The residual insecticide contents were determined using gas chromatography. The washing procedure and the number of washes have a significant effect on the release of active ingredient. Statistically, the two washing methods have the same effect on removing the active ingredient from the Interceptor® and Permanet®2.0 net, but a significantly different influence on the Netprotect® nets. The drying process has no significant effect on the insecticide. Both washing procedures affected the amount of insecticide remaining on nets independently of the impregnation technology. The active ingredient decreases with the number of washing cycles following an exponential or logarithmic model for coated nets. The laboratory hand washing simulation had more impact on the decrease of active ingredient content of the Netprotect® nets. All net types seemed to be effectively

  1. Comparison of the laboratory standard washing using CIPAC washing agent and the domestic washing on three recommended types of long-lasting insecticidal mosquito nets.

    Directory of Open Access Journals (Sweden)

    Jean Pierre Nabléni Ouattara

    Full Text Available One of the best ways to prevent malaria is the use of insecticide-treated bed nets. Manufacturers pursue easier, safer and more efficient nets. Hence, many studies on the efficacy and wash resistance using World Health Organization standards have been reported. The commonly used detergent is "Savon de Marseille", because it closely resembles actually used soaps. At the 54(th Collaborative International Pesticides Analytical Council (CIPAC Technical Meeting in 2010, it was suggested to replace it by a standardized "CIPAC washing agent". The aim of this study was to investigate the difference between a laboratory hand washing simulation using the CIPAC washing agent (method-1 and a domestic washing (method-2 on different bed nets, as well as the effect of the drying process on the release of active ingredient.Interceptor®, Permanet®2.0 and Netprotect® nets were used in three treatments, each repeated 20 times. The first treatment included method-1 washing and indoor drying. The second treatment included method-2 washing and indoor drying. The third treatment used method-2 washing and UV-drying. The residual insecticide contents were determined using gas chromatography.The washing procedure and the number of washes have a significant effect on the release of active ingredient. Statistically, the two washing methods have the same effect on removing the active ingredient from the Interceptor® and Permanet®2.0 net, but a significantly different influence on the Netprotect® nets. The drying process has no significant effect on the insecticide.Both washing procedures affected the amount of insecticide remaining on nets independently of the impregnation technology. The active ingredient decreases with the number of washing cycles following an exponential or logarithmic model for coated nets. The laboratory hand washing simulation had more impact on the decrease of active ingredient content of the Netprotect® nets. All net types seemed to be

  2. Comparison between different liquid-liquid and solid phase methods of extraction prior to the identification of the phenolic fraction present in olive oil washing wastewater from the two-phase olive oil extraction system

    Directory of Open Access Journals (Sweden)

    S. Jiménez-Herrera

    2017-09-01

    Full Text Available Phenolic compounds from olive mill wastewater (OMW, are characterized by a strong antioxidant activity. At the same time, they represent an environmental problem because they are difficult to degrade. The purpose of this work was to identify these biologically active compounds in the OMW from two-phase olive oil production in order to convert a polluting residue into a source of natural antioxidants. After optimizing the extraction process of phenolic compounds using liquid-liquid extraction (LLE and solid phase extraction (SPE methods, it was determined that the most appropriate sequence comprised a previous centrifugation to remove the lipid fraction, followed by liquid extraction with ethyl acetate or SPE. The most important compounds identified in olive oil washing wastewater (OOWW were tyrosol, hydroxytyrosol and succinic acid; whereas the ones in the wastewater derived from the washing of the olives (OWW were cresol, catechol, 4-methylcatechol, hydrocinnamic acid and p-hydroxy-hydrocinnamic acid.

  3. Comparison between different liquid-liquid and solid phase methods of extraction prior to the identification of the phenolic fraction present in olive oil washing wastewater from the two-phase olive oil extraction system

    International Nuclear Information System (INIS)

    Jiménez-Herrera, S.; Ochando-Pulido, J.M.; Martínez-Ferez, A.

    2017-01-01

    Phenolic compounds from olive mill wastewater (OMW), are characterized by a strong antioxidant activity. At the same time, they represent an environmental problem because they are difficult to degrade. The purpose of this work was to identify these biologically active compounds in the OMW from two-phase olive oil production in order to convert a polluting residue into a source of natural antioxidants. After optimizing the extraction process of phenolic compounds using liquid-liquid extraction (LLE) and solid phase extraction (SPE) methods, it was determined that the most appropriate sequence comprised a previous centrifugation to remove the lipid fraction, followed by liquid extraction with ethyl acetate or SPE. The most important compounds identified in olive oil washing wastewater (OOWW) were tyrosol, hydroxytyrosol and succinic acid; whereas the ones in the wastewater derived from the washing of the olives (OWW) were cresol, catechol, 4-methylcatechol, hydrocinnamic acid and p-hydroxy-hydrocinnamic acid. [es

  4. Washing Habits and Machine with Intake of hot and cold Water

    DEFF Research Database (Denmark)

    Christensen, Bente Lis; Nørgaard, Jørgen

    1997-01-01

    with slightly adapted washing habits, or 17% of normal today. If the heat is supplied from combined heat and power production as in the actual experiment, CO2-emission is reduced by 81%. With hot water from oil or gas heaters the reduction will be slightly lower, while with solar hot water it will be larger.......Domestic washing machines typically spend around 80% of the electricity on heating water. Most of this can be replaced by more appropriate heat sources like district heat from combined heat and power production, or gas heating system. In recent years some washing machine manufacturers have marketed...... machines which can take in both hot and cold water and mix it to the temperature wanted. Such one machine has been tested in daily household use over 5 months, with habits of very few hot water washes. The result is an electricity consumption corresponding to 67 kWh per year for an average household...

  5. Characterization, Washing, Leaching, and Filtration of C-104 Sludge

    Energy Technology Data Exchange (ETDEWEB)

    KP Brooks; PR Bredt; GR Golcar; SA Hartley; LK Jagoda; KG Rappe; MW Urie

    2000-06-09

    Approximately 1,400 g of wet Hanford Tank C-104 Sludge was evaluated by Battelle for the high-level waste (HLW) pretreatment processes of ultrafiltration, dilute caustic washing, and elevated-temperature caustic leaching. The filterability of diluted C-104 sludge was measured with a 0.1-{micro}m sintered metal Mott filter using a 24-inch-long, single-element, crossflow filtration system (cells unit filter [CUF]). While the filtrate was being recirculated prior to washing and leaching, a 6.9 wt% solids slurry was evaluated with a matrix of seven 1-hour conditions of varying trans-membrane pressure (30 to 70 psid) and axial velocity (9 to 15 ft/s). The filtrate flux and backpulse efficiency were determined for each condition. The slurry was concentrated to 23 wt% solids, a second matrix of six 1-hour conditions was performed, and data analogous to that recorded in the first matrix were obtained. The low-solids-concentration matrix produced filtrate flux rates that ranged from 0.038 to 0.083 gpm/ft{sup 2}. The high-solids-concentration matrix produced filtrate flux rates that ranged from 0.0095 to 0.0172 gpm/ft{sup 2}. In both cases, the optimum filtrate flux was at the highest axial velocity (15 ft/s) and transmembrane pressure had little effect. Nearly all of the measured filtrate fluxes were more than an order of magnitude greater than the required plant flux for C-104 of 0.00126 gpm/ft{sup 2}. In both matrices, the filtrate flux appeared to be proportional to axial velocity, and the permeability appeared to be inversely proportional to the trans-membrane pressure. The first test condition was repeated as the last test condition for each matrix. In both cases, there was a significant decrease in filtrate flux, indicating some filter fouling during the test matrix that could not be removed by backpulsing alone, although the backpulse number and duration were not optimized. Following testing of these two matrices, the material was washed within the CUF by

  6. Treatment techniques for the recycling of bottle washing water in the soft drinks industry.

    Science.gov (United States)

    Ramirez Camperos, E; Mijaylova Nacheva, P; Diaz Tapia, E

    2004-01-01

    The soft drink production is an important sector in the manufacturing industry of Mexico. Water is the main source in the production of soft drinks. Wastewater from bottle washing is almost 50% of the total wastewater generated by this industry. In order to reduce the consumption of water, the water of the last bottle rinse can be reused in to the bottle pre-rinse and pre-washing cycles. This work presents the characterization of the final bottle washing rinse discharge and the treatability study for the most appropriate treatment system for recycling. Average characteristics of the final bottle wash rinse were as follows: Turbidity 40.46 NTU, COD 47.7 mg/L, TSS 56 mg/L, TS 693.6 mg/L, electrical conductivity 1,194 microS/cm. The results of the treatability tests showed that the final rinse water can be used in the pre-rinse and pre-washing after removing the totality of the suspended solids, 80% of the COD and 75% of the dissolved solids. This can be done using the following treatment systems: filtration-adsorption-reverse osmosis, or filtration-adsorption-ion exchange. The installation of these treatment techniques in the soft drink industry would decrease bottle washing water consumption by 50%.

  7. An assessment of water, sanitation and hygiene (wash) practices ...

    African Journals Online (AJOL)

    An assessment of water, sanitation and hygiene (wash) practices and quality of routinely ... East African Medical Journal ... There was a high uptake of households with treated drinking water (92%), availability of hand washing facilities in ...

  8. Hand washing practices amongst medical students in Port Harcourt ...

    African Journals Online (AJOL)

    Nigerian Health Journal ... Rates of hand washing are low world wide even amongst health care workers who are should know about its importance. The aim of ... The greatest motivation for hand washing was fear of contracting disease, whilst ...

  9. Ceramic wash-coat for catalyst support

    Science.gov (United States)

    Kulkarni, Anand A.; Subramanian, Ramesh; Sabol, Stephen M.

    2012-08-14

    A wash-coat (16) for use as a support for an active catalyst species (18) and a catalytic combustor component (10) incorporating such wash-coat. The wash-coat is a solid solution of alumina or alumina-based material (Al.sub.2O.sub.3-0-3 wt % La.sub.2O.sub.3) and a further oxide exhibiting a coefficient of thermal expansion that is lower than that exhibited by alumina. The further oxide may be silicon dioxide (2-30 wt % SiO.sub.2), zirconia silicate (2-30 wt % ZrSiO.sub.4), neodymium oxide (0-4 wt %), titania (Al.sub.2O.sub.3-3-40% TiO.sub.2) or alumina-based magnesium aluminate spinel (Al.sub.2O.sub.3-25 wt % MgO) in various embodiments. The active catalyst species may be palladium and a second metal in a concentration of 10-50% of the concentration of the palladium.

  10. Washing scaling of GeneChip microarray expression

    Directory of Open Access Journals (Sweden)

    Krohn Knut

    2010-05-01

    Full Text Available Abstract Background Post-hybridization washing is an essential part of microarray experiments. Both the quality of the experimental washing protocol and adequate consideration of washing in intensity calibration ultimately affect the quality of the expression estimates extracted from the microarray intensities. Results We conducted experiments on GeneChip microarrays with altered protocols for washing, scanning and staining to study the probe-level intensity changes as a function of the number of washing cycles. For calibration and analysis of the intensity data we make use of the 'hook' method which allows intensity contributions due to non-specific and specific hybridization of perfect match (PM and mismatch (MM probes to be disentangled in a sequence specific manner. On average, washing according to the standard protocol removes about 90% of the non-specific background and about 30-50% and less than 10% of the specific targets from the MM and PM, respectively. Analysis of the washing kinetics shows that the signal-to-noise ratio doubles roughly every ten stringent washing cycles. Washing can be characterized by time-dependent rate constants which reflect the heterogeneous character of target binding to microarray probes. We propose an empirical washing function which estimates the survival of probe bound targets. It depends on the intensity contribution due to specific and non-specific hybridization per probe which can be estimated for each probe using existing methods. The washing function allows probe intensities to be calibrated for the effect of washing. On a relative scale, proper calibration for washing markedly increases expression measures, especially in the limit of small and large values. Conclusions Washing is among the factors which potentially distort expression measures. The proposed first-order correction method allows direct implementation in existing calibration algorithms for microarray data. We provide an experimental

  11. Speciation of mercury in sludge solids: washed sludge

    Energy Technology Data Exchange (ETDEWEB)

    Bannochie, C. J. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Lourie, A. P. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2017-10-24

    The objective of this applied research task was to study the type and concentration of mercury compounds found within the contaminated Savannah River Site Liquid Waste System (SRS LWS). A method of selective sequential extraction (SSE), developed by Eurofins Frontier Global Sciences1,2 and adapted by SRNL, utilizes an extraction procedure divided into seven separate tests for different species of mercury. In the SRNL’s modified procedure four of these tests were applied to a washed sample of high level radioactive waste sludge.

  12. Irreversible Wash Aid Additive for Cesium Mitigation: WARRP Demonstration

    Energy Technology Data Exchange (ETDEWEB)

    Kaminski, Michael [Argonne National Lab. (ANL), Argonne, IL (United States)

    2015-01-01

    This activity demonstrated, on a practical scale, the primary unit operations for building a containment structure for radioactive wash waters, washing down a hypothetically radioactively contaminated vehicle, collecting the hypothetically radioactive slurry waste water, filtering the hypothetically radioactive wash waters, disassembling the containment, and transporting the materials for final disposition.

  13. The effect of silica in washing with geothermal water, Iceland

    International Nuclear Information System (INIS)

    Lindal, B.

    1992-01-01

    Industrial washing operation using geothermal water in Iceland are reported and testing designed to explain the beneficial effect of geothermal water for washing described. The findings indicate, that the silica content of the water may be the principal component for a superior washing quality

  14. Domestic wash water reclamation for reuse as commode water supply using filtration: Reverse-osmosis separation technique

    Science.gov (United States)

    Hall, J. B., Jr.; Batten, C. E.; Wilkins, J. R.

    1974-01-01

    A combined filtration-reverse-osmosis water recovery system has been evaluated to determine its capability to reclaim domestic wash water for reuse as a commode water supply. The system produced water that met all chemical and physical requirements established by the U.S. Public Health Service for drinking water with the exception of carbon chloroform extractables, methylene blue active substances, and phenols. It is thought that this water is of sufficient quality to be reused as commode supply water. The feasibility of using a combined filtration and reverse-osmosis technique for reclaiming domestic wash water has been established. The use of such a technique for wash-water recovery will require a maintenance filter to remove solid materials including those less than 1 micron in size from the wash water. The reverse-osmosis module, if sufficiently protected from plugging, is an attractive low-energy technique for removing contaminants from domestic wash water.

  15. Remediation of cadmium contamination in paddy soils by washing with chemicals: Selection of washing chemicals

    International Nuclear Information System (INIS)

    Makino, Tomoyuki; Sugahara, Kazuo; Sakurai, Yasuhiro; Takano, Hiroyuki; Kamiya, Takashi; Sasaki, Kouta; Itou, Tadashi; Sekiya, Naoki

    2006-01-01

    The efficiencies of neutral salts, strong acids, and chelates were tested for extracting cadmium (Cd) from three paddy soils. The higher the selectivity of the cations of the added neutral salts toward soil adsorption sites, the lower the pH in the extracts and the more soil Cd could be extracted. In addition, soil carbon and nitrogen contents and mineral composition were closely associated with the amount of Cd extracted. Calcium chloride and iron(III) chloride were selected as wash chemicals to restore Cd-contaminated paddy soils in situ. Washing with calcium chloride led to the formation of Cd chloride complexes, enhancing Cd extraction from the soils. The washing also substantially decreased soil levels of exchangeable and acid-soluble Cd, which are the major forms of bioavailable Cd for rice (Oryza sativa L.). The optimum conditions for in situ soil washing were also determined for calcium chloride. - Calcium chloride and iron(III) chloride were useful for the in situ washing of Cd-contaminated paddy soils

  16. Winter Maintenance Wash-Water Heavy Metal Removal Pilot Scale Evaluation

    Directory of Open Access Journals (Sweden)

    Christopher M. Miller

    2016-01-01

    Full Text Available To encourage sustainable engineering practices, departments of transportation are interested in reusing winter maintenance truck wash water as part of their brine production and future road application. Traffic-related metals in the wash water, however, could limit this option. The objective of this work was to conduct a pilot scale evaluation of heavy metal (copper, zinc, iron, and lead removal in a filtration unit (maximum flow rate of 45 L/minute containing proprietary (MAR Systems Sorbster® media. Three different trials were conducted and approximately 10,000 L of wash water collected from a winter maintenance facility in Ohio was treated with the pilot unit. Lab studies were also performed on six wash-water samples from multiple facilities to assess particle size removal and estimate settling time as a potential removal mechanism during wash-water storage. Pilot unit total metal removal efficiencies were 79%, 77%, 63%, and 94% for copper, zinc, iron, and lead, respectively. Particle settling calculation estimates for copper and zinc show that 10 hours in storage can also effectively reduce heavy metal concentrations in winter maintenance wash water in excess of 70%. These pilot scale results show promise for reducing heavy metal concentrations to an acceptable level for reuse.

  17. Radiotracer study of wash load movement in a drum-type fabric washing machine using a gamma camera

    Energy Technology Data Exchange (ETDEWEB)

    Balt, A.P.; Brekel, L.D.M. van den; Vandecasteele, C.; Kolar, Z.

    1987-01-01

    A study was made of the movement of the wash loads in a drum-type washing machine. For this purpose a sup(99m)Tc source was attached to one or two separate textile pieces and the subsequent source positions were determined by means of a gamma-camera. The wash load movement pattern appears to depend on the type of textile material and its amount, as well as on the volume of water present in the washing machine.

  18. Radiotracer study of wash load movement in a drum-type fabric washing machine using a gamma camera

    International Nuclear Information System (INIS)

    Balt, A.P.; Brekel, L.D.M. van den; Vandecasteele, C.; Kolar, Z.

    1987-01-01

    A study was made of the movement of the wash loads in a drum-type washing machine. For this purpose a sup(99m)Tc source was attached to one or two separate textile pieces and the subsequent source positions were determined by means of a gamma-camera. The wash load movement pattern appears to depend on the type of textile material and its amount, as well as on the volume of water present in the washing machine. (author)

  19. Use of pulsed neutron logging to evaluate perforation washing

    International Nuclear Information System (INIS)

    Dimon, C.A.

    1986-01-01

    This invention relates to the use of pulsed neutron logging techniques before and after perforation washing operations are performed to evaluate the degree of success of the perforation washing operations. Well logging operations of a type designed to respond to the difference between a formation immediately behind the well sheath and voids in the formation are performed both before and after the perforation washing operation. differences between the two resulting logs are then indicative of voids created by perforation washing. In a preferred embodiment, pulsed neutron logging is used as the logging technique, while a weighted brine having a high absorption cross section to pulsed neutrons is used as the perforation washing fluid

  20. EBR-II Primary Tank Wash-Water Alternatives Evaluation

    International Nuclear Information System (INIS)

    Demmer, R.; Heintzelman, J.; Squires, L.; Meservey, R.

    2009-01-01

    The EBR-II reactor at Idaho National Laboratory was a liquid sodium metal cooled reactor that operated for 30 years. Approximately 1100 kg of residual sodium remained in the primary system after draining the bulk sodium. To stabilize the remaining sodium, both the primary and secondary systems were treated with a purge of moist carbon dioxide. The passivation treatment was stopped in 2005 and the primary system is maintained under a blanket of dry carbon dioxide. Approximately 670 kg of sodium metal remains in the primary system in locations that were inaccessible to passivation treatment or in pools of sodium that were too deep for complete penetration of the passivation treatment. The EBR-II reactor was permitted by the Idaho Department of Environmental Quality (DEQ) in 2002 under a RCRA permit that requires removal of all remaining sodium. The proposed baseline closure method would remove the large components from the primary tank, fill the primary system with water, react the remaining sodium with the water and dissolve the reaction products in about 100,000 gallons of wash water. On February 19-20, 2008, a workshop was held in Idaho Falls, Idaho, to evaluate alternatives that could meet the RCRA permit clean closure requirements and minimize the quantity of hazardous waste generated by the cleanup process. The workshop convened a panel of national and international sodium cleanup specialists, subject matter experts from the INL, and the EBR-II Wash Water Project team that organized the workshop. The workshop was conducted by a trained facilitator using Value Engineering techniques to elicit the most technically sound solutions from the workshop participants. A brainstorming session was held to identify possible alternative treatment methods that would meet the primary functions and criteria of neutralizing the hazards, maximizing byproduct removal and minimizing waste generation. An initial list of some 20 probable alternatives was evaluated and refined down

  1. Fracture coatings in Topopah Spring Tuff along drill hole wash

    International Nuclear Information System (INIS)

    Carlos, B.A.; Chipera, S.J.; Bish, D.L.

    1994-01-01

    Fracture-lining minerals are being studied as part of site characterization to determine the suitability of Yucca Mountain, Nevada as a potential high level nuclear waste repository. Fracture coatings in the Paintbrush Group provide information on potential flow paths above the water table both toward and away from the potential repository and provide information on the distribution of fracture-lining minerals needed to model thermal effects of waste emplacement. Fracture coatings within the predominantly non-zeolitic Paintbrush Group vary both with depth and laterally across Yucca Mountain, whereas fracture coatings in tuffs below the Paintbrush Group are related to the mineralogy of the tuffs and follow a consistent pattern of distribution with predominantly quartz, calcite, and manganese oxides in the devitrified intervals and mordenite and clinoptilolite in the zeolitic intervals. The zeolites stellerite and heulandite are more abundant in fractures in the Topopah Spring Tuff in drill holes USW G-1 and UE-25 a number-sign l, located along Drill Hole Wash (at the northern end of Yucca Mountain) than in core from other parts of Yucca Mountain. Buesch et al. (2) present evidence for a complex fault system along Drill Hole Wash. To investigate the possibility that the abundant fracture-lining zeolites in USW G-1 and UE-25 a number-sign 1 are related to the Drill Hole Wash fault, the Topopah Spring Tuff was examined in drill cores from USW UZ-14, USW G-1, USW NRG-7/7a, and UE-25 a number-sign l

  2. May car washing represent a risk for Legionella infection?

    Science.gov (United States)

    Baldovin, T; Pierobon, A; Bertoncello, C; Destefani, E; Gennari, M; Stano, A; Baldo, V

    2018-01-01

    Legionella is a ubiquitous Gram-negative bacterium naturally found in aquatic environments. It can pose a health problem when it grows and spreads in man-made water systems. Legionella pneumophila is the most common cause of Legionnaires' disease nowadays, a community-acquired pneumonia with pulmonary symptoms and chest radiography no different from any other form of infectious pneumonia. Legionella monitoring is important for public health reasons, including the identification of unusual environmental sources of Legionella. We report two cases of Legionnaires' disease associated with two different car wash installations in the province of Vicenza, in the Veneto region, northeastern Italy. Patients were not employees of the car wash installations, but users of the service. In both cases, Legionella antigen was detected in urine using the Alere BinaxNOW® Legionella Urinary Antigen, and Legionella antibodies were detected in serum using SERION ELISA classic Legionella pneumophila 1-7 IgG and IgM. Water samples were also analyzed as part of the surveillance program for Legionella prevention and control in compliance with the Italian guidelines. Both patients had clinical symptoms and chest radiography compatible with pneumonia, and only one of them had diabetes as a risk factor. Legionella urinary antigen and serological test on serum samples were positive for Legionella in both patients, even if much slighter in the case A due to the retrospective serological investigation performed a year later the episode and after the second clinical case occurred in the same district. The environmental investigations highlighted two different car wash plants as potential source of infection. A certified company using shock hyperchlorination was asked to disinfect the two plants and, subsequently, control samples resulted negative for Legionella pneumophila. Any water source producing aerosols should be considered at risk for the transmission of Legionella bacteria, including car

  3. Axial Dispersion during Hanford Saltcake Washing

    International Nuclear Information System (INIS)

    Josephson, Gary B.; Geeting, John GH; Lessor, Delbert L.; Barton, William B.

    2006-01-01

    Clean up of Hanford salt cake wastes begins with dissolution retrieval of the sodium rich salts that make up the dominant majority of mass in the tanks. Water moving through the porous salt cake dissolves the soluble components and also displaces the soluble radionuclides (e.g. 137Cs and 99TcO4- ). The separation that occurs from this displacement, known as Selective dissolution, is an important component in Hanford?s pretreatment of low activity wastes for subsequent Supplemental treatment. This paper describes lab scale testing conducted to evaluate Selective dissolution of cesium from non-radioactive Hanford tank 241-S-112 salt cake simulant containing the primary chemicals found the actual tank. An modified axial dispersion model with increasing axial dispersion was developed to predict cesium removal. The model recognizes that water dissolves the salt cake during washing, which causes an increase in the axial dispersion during the wash. This model was subsequently compared with on-line cesium measurements from the retrieval of tank 241-S-112. The model had remarkably good agreement with both the lab scale and full scale data

  4. Experimental study of variations in background radiation and the effect on Nuclear Car Wash sensitivity

    International Nuclear Information System (INIS)

    Church, J; Slaughter, D; Norman, E; Asztalos, S; Biltoft, P

    2007-01-01

    Error rates in a cargo screening system such as the Nuclear Car Wash [1-7] depend on the standard deviation of the background radiation count rate. Because the Nuclear Car Wash is an active interrogation technique, the radiation signal for fissile material must be detected above a background count rate consisting of cosmic, ambient, and neutron-activated radiations. It was suggested previously [1,6] that the Corresponding negative repercussions for the sensitivity of the system were shown. Therefore, to assure the most accurate estimation of the variation, experiments have been performed to quantify components of the actual variance in the background count rate, including variations in generator power, irradiation time, and container contents. The background variance is determined by these experiments to be a factor of 2 smaller than values assumed in previous analyses, resulting in substantially improved projections of system performance for the Nuclear Car Wash

  5. Aqueous treatment of water-sensitive paper objects: capillary unit, blotter wash or paraprint wash?

    NARCIS (Netherlands)

    Schalkx, H.; Iedema, P.; Reissland, B.; van Velzen, B.

    2011-01-01

    Blotter washing andwashing with the capillary unit are both methods used for aqueoustreatment of water-sensitive paper objects. The challenge of thistreatment is to remove water-soluble products while keeping thewater-sensitive medium in its place. In this article the two methodsare compared, along

  6. Enhanced salmonella reduction on tomatoes washed in chlorinated water with wash aid T-128

    Science.gov (United States)

    Chlorine is widely used by the fresh and fresh-cut produce industries to reduce microbial populations and to prevent potential pathogen cross contamination during produce washing. However, the organic materials released from produce quickly react with chlorine and degrade its efficacy for pathogen i...

  7. EFRT M-12 Issue Resolution: Solids Washing

    Energy Technology Data Exchange (ETDEWEB)

    Baldwin, David L.; Schonewill, Philip P.; Toth, James J.; Huckaby, James L.; Eslinger, Paul W.; Hanson, Brady D.; Kurath, Dean E.; Minette, Michael J.

    2010-01-01

    Pacific Northwest National Laboratory (PNNL) was tasked by Bechtel National Inc. (BNI) on the River Protection Project-Hanford Tank Waste Treatment and Immobilization Plant (RPP-WTP) project to perform research and development activities to resolve technical issues identified for the Pretreatment Facility (PTF). The Pretreatment Engineering Platform (PEP) was designed, constructed, and operated as part of a plan to respond to issue M12, “Undemonstrated Leaching Processes” of the External Flowsheet Review Team (EFRT) issue response plan.( ) The PEP is a 1/4.5-scale test platform designed to simulate the WTP pretreatment caustic leaching, oxidative leaching, ultrafiltration solids concentration, and slurry washing processes. The PEP replicates the WTP leaching processes using prototypic equipment and control strategies. The PEP also includes non-prototypic ancillary equipment to support the core processing.

  8. Innovative Technology for Preparing Washing Liquid During Well Drilling

    Directory of Open Access Journals (Sweden)

    Davydenko A.N.

    2015-09-01

    Full Text Available Technology of washings liquid preparation is worked out. Prospects of the hydrodynamic supercavitation use for preparation of washing liquids during well drilling are substantiated. Theoretical research make it possible to set parameters and work out the construction of cavitational dispergator. The results of theoretical research found their confirmation during practical examinations and became the basis for creation of the technique of washing liquid preparation and construction of cavitational dispergator tested in production conditions.

  9. WASH and gender in health care facilities: The uncharted territory.

    Science.gov (United States)

    Kohler, Petra; Renggli, Samuel; Lüthi, Christoph

    2017-11-08

    Health care facilities in low- and middle-income countries are high-risk settings, and face special challenges to achieving sustainable water, sanitation, and hygiene (WASH) services. Our applied interdisciplinary research conducted in India and Uganda analyzed six dimensions of WASH services in selected health care facilities, including menstrual hygiene management. To be effective, WASH monitoring strategies in health care facilities must include gender sensitive measures. We present a novel strategy, showing that applied gender sensitive multitool assessments are highly productive in assessments of WASH services and facilities from user and provider perspectives. We discuss its potential for applications at scale and as an area of future research.

  10. The impact of aqueous washing on the ability of βFeOOH to corrode iron.

    Science.gov (United States)

    Watkinson, D E; Emmerson, N J

    2017-01-01

    Controlling the corrosion of historical and archaeological ferrous metal objects presents a significant challenge to conservators. Chloride is a major corrosion accelerator in coastal areas for historic ferrous metal structures and for the many chloride-containing archaeological objects within museums. Corrosion reactions involve the formation of akaganéite (βFeOOH) which incorporates chloride within its crystal structure and adsorbs it onto its surface. The mobility of the surface-adsorbed chloride in aqueous systems and atmospheric moisture means βFeOOH can itself cause iron to corrode. The extraction of chloride from βFeOOH by aqueous Soxhlet hot wash and aqueous room temperature washing is measured. The impact of this washing on the ability of βFeOOH to corrode iron is quantitatively investigated by determining the oxygen consumption of unwashed, Soxhlet-washed and room temperature-washed samples of βFeOOH mixed with iron powder and exposed to 80 % relative humidity. This acts as a proxy measurement for the corrosion rate of iron. The results are discussed relative to climatic factors for outdoor heritage objects and the treatment of archaeological iron in museums. Delivering better understanding of the properties of βFeOOH supports the development of evidence-based treatments and management procedures in heritage conservation.

  11. Eye wash water flow direction study: an evaluation of the effectiveness of eye wash devices with opposite directional water flow.

    Science.gov (United States)

    Fogt, Jennifer S; Jones-Jordan, Lisa A; Barr, Joseph T

    2018-01-01

    New designs of eye wash stations have been developed in which the direction of water flow from the fountain has been reversed, with two water streams originating nasally in both eyes and flowing toward the temporal side of each eye. No study has been done to determine the ideal direction of water flow coming from the eye wash in relation to the eye. Ophthalmic eye examinations were conducted before and after the use of two eye wash stations with opposite water flow directionality. Fluorescein was instilled in both eyes before using an eye wash to measure the effectiveness of the water flow. Subjects were surveyed upon their experiences using the eye washes. Ophthalmic examination found no significant difference in the efficacy of the eye washes with nasal-to-temporal water flow when compared to temporal-to-nasal water flow direction.

  12. Transport of phosphorus, wash load and suspended sediment in the River Varde A in southwest Jutland, Denmark

    DEFF Research Database (Denmark)

    Thodsen, Hans; Hasholt, Bent; Pejrup, Morten

    2004-01-01

    Total phosphorus (TP) concentrations, suspended sediment concentrations (SSC) and wash load have been measured at three river monitoring stations in the River Varde Angstrom system since 1998. This provides the possibility of studying the link between SSC and wash load and concentrations of TP...... at the end of a small impoundment. Transport rates at the upstream stations were 57% higher for suspended sediment and 27% higher for wash load than at the downstream station, while transport of TP was the same. This indicates that phosphorus is transported adhered to the finest grain size fractions that do...

  13. Rapid washing of filter paper discs in a solid-phase radioimmunoassay with a constant flow washing device

    International Nuclear Information System (INIS)

    Kemeny, D.M.; West, F.B.

    1982-01-01

    A machine has been developed for the rapid washing of the cellulose filter paper discs that are used in a number of radioimmunoassays. The machine is simple in design, easy to use, and is capable of washing 96 filter paper discs simultaneously. The efficiency of the machine is demonstrated by a RAST assay for measuring IgE antibodies to the venom. Time taken to wash the discs was reduced 3-fold without loss of sensitivity or reproducibility. (Auth.)

  14. A novel study on UV protection and antibacterial properties of washed denim garment

    Directory of Open Access Journals (Sweden)

    Pervez Md. Nahid

    2017-01-01

    Full Text Available On this planet, many investigations are applied to switch conventional chemical cloth techniques via eco-pleasant and economically attractive bioprocesses using enzymes. The present study offers an enzymatic washing system using enzyme (Cellzyme SPL H/C for boosting the ultraviolet and antimicrobial undertaking of denim garments. Experimental results showed that the 4.0% o.w.f enzyme awareness furnished a greater UPF than the other concentrations and before washed. Results divulge that enzyme (Cellzyme SPL H/C not handiest preserve the fabric surface from UV degradation but also performed extended degree of antibacterial endeavour in opposition to some species of bacteria that leading to act as a nice antibacterial agent on the denim materials. The enzyme washing healing diminished the skin hairiness and accelerated the skin evenness of the denim fibres as shown by means of SEM measurements.

  15. Suitability of olive oil washing water as an electron donor in a feed batch operating bio-electrochemical system; Idoneidad del agua de lavado de aceites de oliva como donador de electrones en un sistema alimentado por lotes bioelectroquímico

    Energy Technology Data Exchange (ETDEWEB)

    Fermoso, F.G.; Fernández-Rodríguez, M.J.; Jiménez-Rodríguez, A.; Serrano, A.; Borja, R.

    2017-07-01

    Olive oil washing water derived from the two-phase manufacturing process was assessed as an electron donor in a bio-electrochemical system (BES) operating at 35 ºC. Start-up was carried out by using acetate as a substrate for the BES, reaching a potential of around +680 mV. After day 54, BES was fed with olive oil washing water. The degradation of olive oil washing water in the BES generated a maximum voltage potential of around +520 mV and a Chemical Oxygen Demand (COD) removal efficiency of 41%. However, subsequent loads produced a decrease in the COD removal, while current and power density diminished greatly. The deterioration of these parameters could be a consequence of the accumulation of recalcitrant or inhibitory compounds, such as phenols. These results demonstrated that the use of olive oil washing water as an electron donor in a BES is feasible, although it has to be further investigated in order to make it more suitable for a real application. [Spanish] El agua de lavado del aceite de oliva procedente del proceso de elaboración en dos fases fue utilizada como donador de electrones en un Sistema Bioelectroquímico (BES) operado a 35ºC. Se realizó una etapa de arranque del sistema mediante alimentación con acetato, alcanzando un potencial de referencia de +680 mV. Tras 54 días, el sistema se alimentó con agua de lavado de aceite, generando un potencial máximo de +520 mV y una eliminación de materia del 41%, en demanda química de oxígeno. Sin embargo, cargas subsecuentes conllevaron una bajada en la eliminación de materia, mientras que la densidad de corriente y de potencia disminuyeron ostensiblemente. El empeoramiento de estos parámetros puede deberse a la acumulación de compuestos recalcitrantes o inhibidores, como fenoles. Por tanto, el uso del agua de lavado de aceite de oliva en un BES es factible, aunque es necesario llevar a cabo nuevas investigaciones que hagan más atractiva su aplicación a escala real.

  16. [Biosynthesis of enniatin by washed cells of Fusarium sambucinum].

    Science.gov (United States)

    Minasian, A E; Chermenskĭ, D N; Bezborodov, A M

    1979-01-01

    Biosynthesis of the depsipeptide membrane ionophore--enniatin B by the washed mycelium Fusarium sambucinum Fuck 52 377 was studied. Metabolic precursors of enniatin B, alpha-ketovaleric acid, 14C-L-valine, and 14CH3-methionine, were added to the system after starvation. The amino acid content in the metabolic pool increased 1.5 times after addition of alpha-ketovaleric acid, 2.2 times after that of valine, and 2.5 times after addition of methionine. 14C-L-valine and 14CH3-methionine were incorporated into the molecule of enniatin B. Valine methylation in the molecule occurred at the level of synthesized depsipeptide. Amino acids of the metabolic pool performed the regulatory function in the synthesis.

  17. Road dust emission sources and assessment of street washing effect

    NARCIS (Netherlands)

    Karanasiou, A.; Amato, F.; Moreno, T.; Lumbreras, J.; Borge, R.; Linares, C.; Boldo, E.; Alastuey, A.; Querol, X.

    2014-01-01

    Although previous studies report on the effect of street washing on ambient particulate matter levels, there is a lack of studies investigating the results of street washing on the emission strength of road dust. A sampling campaign was conducted in Madrid urban area during July 2009 where road dust

  18. Hand Washing Practices and Compliance among Health Care ...

    African Journals Online (AJOL)

    Hand washing is the simplest, most inexpensive and most effective method of reducing the incidence of hospital-acquired infections in the Intensive Care Unit. Several reports have shown a relationship between improved hand washing practices and reduced infection rates. We conducted a prospective, ...

  19. Effects of shampoo and water washing on hair cortisol concentrations.

    Science.gov (United States)

    Hamel, Amanda F; Meyer, Jerrold S; Henchey, Elizabeth; Dettmer, Amanda M; Suomi, Stephen J; Novak, Melinda A

    2011-01-30

    Measurement of cortisol in hair is an emerging biomarker for chronic stress in human and nonhuman primates. Currently unknown, however, is the extent of potential cortisol loss from hair that has been repeatedly exposed to shampoo and/or water. Pooled hair samples from 20 rhesus monkeys were subjected to five treatment conditions: 10, 20, or 30 shampoo washes, 20 water-only washes, or a no-wash control. For each wash, hair was exposed to a dilute shampoo solution or tap water for 45 s, rinsed 4 times with tap water, and rapidly dried. Samples were then processed for cortisol extraction and analysis using previously published methods. Hair cortisol levels were significantly reduced by washing, with an inverse relationship between number of shampoo washes and the cortisol concentration. This effect was mainly due to water exposure, as cortisol levels following 20 water-only washes were similar to those following 20 shampoo treatments. Repeated exposure to water with or without shampoo appears to leach cortisol from hair, yielding values that underestimate the amount of chronic hormone deposition within the shaft. Collecting samples proximal to the scalp and obtaining hair washing frequency data may be valuable when conducting human hair cortisol studies. Copyright © 2010 Elsevier B.V. All rights reserved.

  20. Innovative approaches for the remediation of arsenic and mercury pollution via soil washing

    International Nuclear Information System (INIS)

    Sierra, C.; Gonzalez-Coto, F.; Villa, R.; Menendez-Aguado, J. M.; Gallego, J. R.

    2009-01-01

    Soil washing techniques are ex situ remediation procedures to remove contaminants concentrating them into a minor volume through particle size separation, gravity separation, and attrition scrubbing; with or without the utilization of chemical additives. Systems incorporating these removal techniques offer possibilities for application to soils contaminated with a wide variety of heavy metal, radionuclides, and organic contaminants. (Author)

  1. Performance of ceramic ultrafiltration and reverse osmosis membranes in treating car wash wastewater for reuse.

    Science.gov (United States)

    Moazzem, Shamima; Wills, Jamie; Fan, Linhua; Roddick, Felicity; Jegatheesan, Veeriah

    2018-03-01

    Reusing treated effluents in industries is a great option to conserve freshwater resources. For example, car wash centres all over Australia are estimated to use 17.5 billion litres of water and discharge it as wastewater and spend $75 million a year for both purchasing fresh water and for treating and/or discharging the wastewater. Therefore, it is important to develop simple but reliable systems that can help to treat and reuse car wash wastewater. Significant savings could also be associated with the implementation of such systems. This study evaluates the performance of granular and membrane filtration systems with coagulation/flocculation and sedimentation in treating car wash wastewater for the purpose of reuse. Overall, 99.9% of turbidity, 100% of suspended solids and 96% of COD were removed from the car wash wastewater after treating by coagulation, flocculation, sedimentation, sand filtration, ceramic ultrafiltration and reverse osmosis and the treated water meets the standards required for class A recycled water in Australia and standards imposed in Belgium and China. The treated water can be reused. However, optimisation is required to reduce the sludge produced by this system.

  2. Irreversible Wash Aid Additive for Cesium Mitigation. Small-Scale Demonstration and Lessons Learned

    Energy Technology Data Exchange (ETDEWEB)

    Kaminski, Michael [Argonne National Lab. (ANL), Argonne, IL (United States)

    2015-01-01

    The Irreversible Wash Aid Additive process has been under development by the U.S. Environmental Protection Agency (EPA) and Argonne National Laboratory (Argonne). This process for radioactive cesium mitigation consists of a solution to wash down contaminated structures, roadways, and vehicles and a sequestering agent to bind the radionuclides from the wash water and render them environmentally immobile. The purpose of this process is to restore functionality to basic services and immediately reduce the consequences of a radiologically-contaminated urban environment. Research and development have resulted in a down-selection of technologies for integration and demonstration at the pilot-scale level as part of the Wide Area Recovery and Resiliency Program (WARRP) under the Department of Homeland Security and the Denver Urban Area Security Initiative. As part of developing the methods for performing a pilot-scale demonstration at the WARRP conference in Denver in 2012, Argonne conducted small-scale field experiments at Separmatic Systems. The main purpose of these experiments was to refine the wash water collection and separations systems and demonstrate key unit operations to help in planning for the large scale demonstration in Denver. Since the purpose of these tests was to demonstrate the operations of the system, we used no radioactive materials. After a brief set of experiments with the LAKOS unit to familiarize ourselves with its operation, two experiments were completed on two separate dates with the Separmatic systems.

  3. Wash-off effects in urban areas

    International Nuclear Information System (INIS)

    Mueck, K.; Steger, F.

    1991-01-01

    The reduction of the activity distributed in urban areas in three Austrian cities after a radioactive fall-out, by run-off and wash-off effects from stabilised surfaces and the resulting dose reduction to the population were investigated four years after the Chernobyl fall-out to predict the long term external exposure of the population. The measurements were performed in cities with different fractions of dry and wet deposition after the Chernobyl accident in order to determine whether any differences in radionuclide removal with regard to wet and dry fall-out was observable. High resolution in situ gamma spectroscopy was employed to measure the gamma flux from 137 Cs and 134 Cs at points over stabilised surfaces, which was then compared with undisturbed grass surfaces. The average reduction of the place activity on stabilised surfaces amounted to a factor of 10±5 compared to the original deposition after the fall-out. Asphalt showed the highest reduction factor (11.4), concrete less (8.1), stone slabs and cobblestone only about 4.5 and gravel virtually no reduction (1.1). Only very little variation of this reduction with dry or wet deposition was observed. (author)

  4. Effectiveness of Commercial and Homemade Washing Agents in Removing Pesticide Residues on and in Apples.

    Science.gov (United States)

    Yang, Tianxi; Doherty, Jeffery; Zhao, Bin; Kinchla, Amanda J; Clark, John M; He, Lili

    2017-11-08

    Removal of pesticide residues from fresh produce is important to reduce pesticide exposure to humans. This study investigated the effectiveness of commercial and homemade washing agents in the removal of surface and internalized pesticide residues from apples. Surface-enhanced Raman scattering (SERS) mapping and liquid chromatography tandem mass spectrometry (LC-MS/MS) methods were used to determine the effectiveness of different washing agents in removing pesticide residues. Surface pesticide residues were most effectively removed by sodium bicarbonate (baking soda, NaHCO 3 ) solution when compared to either tap water or Clorox bleach. Using a 10 mg/mL NaHCO 3 washing solution, it took 12 and 15 min to completely remove thiabendazole or phosmet surface residues, respectively, following a 24 h exposure to these pesticides, which were applied at a concentration of 125 ng/cm 2 . LC-MS/MS results showed, however, that 20% of applied thiabendazole and 4.4% of applied phosmet had penetrated into the apples following the 24 h exposure. Thiabendazole, a systemic pesticide, penetrated 4-fold deeper into the apple peel than did phosmet, a non-systemic pesticide, which led to more thiabendazole residues inside the apples, which could not be washed away using the NaHCO 3 washing solution. This study gives us the information that the standard postharvest washing method using Clorox bleach solution for 2 min is not an effective means to completely remove pesticide residues on the surface of apples. The NaHCO 3 method is more effective in removing surface pesticide residues on apples. In the presence of NaHCO 3 , thiabendazole and phosmet can degrade, which assists the physical removal force of washing. However, the NaHCO 3 method was not completely effective in removing residues that have penetrated into the apple peel. The overall effectiveness of the method to remove all pesticide residues diminished as pesticides penetrated deeper into the fruit. In practical application

  5. European soil washing for U.S. applications

    Energy Technology Data Exchange (ETDEWEB)

    Mann, Michael J [Geraghty and Miller, Inc., Tampa, PL (United States)

    1992-07-01

    The purpose of this paper is to present the details of the introduction of a new soil treatment technology to the U.S. market. For the purposes of this presentation, I would like to introduce a concept of three tiers of contaminated soil treatment; traditional treatment technologies, alternative treatment technologies and emerging treatment technologies. Traditional treatment consists of landfilling, incineration, and stabilization. Alternative technologies consist of low-temperature thermal treatment, bioremediation, vapor extraction, and physical screening and separation to achieve volume reduction...the essence of soil washing. Emerging technologies currently include in-situ vitrification, RF processes, dechlorination, and possibly some extraction techniques. This paper focuses on the alternative soil technologies. One of the most important lessons we have learned over the past decade is that no single technology provides a broad enough capability to solve all the soil situations that we encounter - the key to feasible and cost-effective site solutions is the ability to optimize the use of reasonable alternatives in a site-specific matrix of use. The Environmental Protection Agency (EPA) has recognized this need and particularly with SARA, emphasized the importance of 'on-site' treatment technologies. This policy was initially stimulated through the development of the SITES program and most recently expanded by the formation of the Technology Innovation Office. Still, all technologies have their limitations. The limitations that are most commonly encountered are: The volume of soil is too big or too small; The contaminants species and/or concentration is not process-compatible; Organics and inorganics cannot be handled in the same treatment train; The process has little or no commercial operations experience. This document is intended to provide a description of a commercial soil-washing facility operating in Holland for the past seven years and to demonstrate

  6. Sequential Washing with Electrolyzed Alkaline and Acidic Water Effectively Removes Pathogens from Metal Surfaces.

    Directory of Open Access Journals (Sweden)

    Yuichiro Nakano

    Full Text Available Removal of pathogenic organisms from reprocessed surgical instruments is essential to prevent iatrogenic infections. Some bacteria can make persistent biofilms on medical devices. Contamination of non-disposable equipment with prions also represents a serious risk to surgical patients. Efficient disinfection of prions from endoscopes and other instruments such as high-resolution cameras remains problematic because these instruments do not tolerate aggressive chemical or heat treatments. Herein, we develop a new washing system that uses both the alkaline and acidic water produced by electrolysis. Electrolyzed acidic water, containing HCl and HOCl as active substances, has been reported to be an effective disinfectant. A 0.15% NaCl solution was electrolyzed and used immediately to wash bio-contaminated stainless steel model systems with alkaline water (pH 11.9 with sonication, and then with acidic water (pH 2.7 without sonication. Two bacterial species (Staphylococcus aureus and Pseudomonas aeruginosa and a fungus (Candida albicans were effectively removed or inactivated by the washing process. In addition, this process effectively removed or inactivated prions from the stainless steel surfaces. This washing system will be potentially useful for the disinfection of clinical devices such as neuroendoscopes because electrolyzed water is gentle to both patients and equipment and is environmentally sound.

  7. Design and optimisation of purification procedure for biodiesel washing

    Directory of Open Access Journals (Sweden)

    S.B. Glišić

    2009-09-01

    Full Text Available Almost complete methanolysis of triglycerides is usually not enough to fulfil the strict standards of biodiesel quality. A key step in this process is neutralization of alkali (catalyst followed by the washing procedure necessary for removing different impurities such as traces of catalyst and methanol and removal of soaps and glycerol from esters phase. The washing with hot water is still widely used in many industrial units for the biodiesel production. In this study, different procedures of biodiesel washing using hot water were investigated. The orto-phosphoric acid was suggested as the best compound for alkali catalyst (sodium hydroxide neutralization. The main goal of the performed analysis was to minimize the water usage in the washing-neutralization step during the biodiesel production. Such solution would make the process of biodiesel synthesis more economical taking into account the decrease of energy consumed for evaporation of water during the final product purification, as well as more acceptable procedure related to the impact on environment (minimal waste water release. Results of the performed simulation of the washing process supported by original experimental data suggested that neutralization after the optimized washing process of the methyl ester layer could be the best solution. The proposed washing procedure significantly decreases the amount of waste water giving at the same time the desired purity of final products (biodiesel and glycerol. The simulation of the process was performed using ASPEN plus software supported by ELCANTREL and UNIQUAC procedure of required properties calculation

  8. Challenges and Opportunities for Mainstreaming Climate Change Adaptation into WaSH Development Planning in Ghana.

    Science.gov (United States)

    Alhassan, Salley; Hadwen, Wade L

    2017-07-10

    Climate change threatens water, sanitation and hygiene (WaSH) facilities and services, as these are intimately linked to the water cycle and are vulnerable to changes in the quantity and quality of available water resources. Floods and droughts, which pollute and reduce water delivery respectively, have now become a perennial issue to deal with in the northern regions of Ghana. This study aimed to assess the degree to which climate change adaptation measures are mainstreamed into the water, sanitation and hygiene (WaSH) development planning process in Ghana. Stakeholders from government and non-government agencies were interviewed to gain perspectives on the threat of climate change, the inclusion of climate change in WaSH planning and the barriers preventing mainstreaming. Despite awareness of climate change, adaptation measures have not been considered, and the immediate WaSH needs remain the priority. Overall, stakeholders felt the adaptive capacity of the Municipality was low and that mainstreaming has not yet occurred. Despite the lack of progress, there are great opportunities for mainstreaming climate change adaptation into planning through increasing awareness and capacity, legislative and institutional changes and the development of participatory systems to provide early warning systems and disaster risk analyses that will inform future planning.

  9. Challenges and Opportunities for Mainstreaming Climate Change Adaptation into WaSH Development Planning in Ghana

    Directory of Open Access Journals (Sweden)

    Salley Alhassan

    2017-07-01

    Full Text Available Climate change threatens water, sanitation and hygiene (WaSH facilities and services, as these are intimately linked to the water cycle and are vulnerable to changes in the quantity and quality of available water resources. Floods and droughts, which pollute and reduce water delivery respectively, have now become a perennial issue to deal with in the northern regions of Ghana. This study aimed to assess the degree to which climate change adaptation measures are mainstreamed into the water, sanitation and hygiene (WaSH development planning process in Ghana. Stakeholders from government and non-government agencies were interviewed to gain perspectives on the threat of climate change, the inclusion of climate change in WaSH planning and the barriers preventing mainstreaming. Despite awareness of climate change, adaptation measures have not been considered, and the immediate WaSH needs remain the priority. Overall, stakeholders felt the adaptive capacity of the Municipality was low and that mainstreaming has not yet occurred. Despite the lack of progress, there are great opportunities for mainstreaming climate change adaptation into planning through increasing awareness and capacity, legislative and institutional changes and the development of participatory systems to provide early warning systems and disaster risk analyses that will inform future planning.

  10. Influence of the washing program on the blood processing performance of a continuous autotransfusion device.

    Science.gov (United States)

    Yoon, Chiyul; Noh, Seungwoo; Lee, Jung Chan; Ko, Sung Ho; Ahn, Wonsik; Kim, Hee Chan

    2014-03-01

    The continuous autotransfusion system has been widely used in surgical operations. It is known that if oil is added to blood, and this mixture is then processed by an autotransfusion device, the added oil is removed and reinfusion of fat is prevented by the device. However, there is no detailed report on the influence of the particular washing program selected on the levels of blood components including blood fat after continuous autotransfusion using such a system. Fresh bovine blood samples were processed by a commercial continuous autotransfusion device using the "emergency," "quality," and "high-quality" programs, applied in random order. Complete blood count (CBC) and serum chemistry were analyzed to determine how the blood processing performance of the device changes with the washing program applied. There was no significant difference in the CBC results obtained with the three washing programs. Although all of the blood lipids in the processed blood were decreased compared to those in the blood before processing, the levels of triglyceride, phospholipid, and total cholesterol after processing via the emergency program were significantly higher than those present after processing via the quality and high-quality programs. Although the continuous autotransfusion device provided consistent hematocrit quality, the levels of some blood lipid components showed significant differences among the washing programs.

  11. Hand washing frequencies and procedures used in retail food services.

    Science.gov (United States)

    Strohbehn, Catherine; Sneed, Jeannie; Paez, Paola; Meyer, Janell

    2008-08-01

    Transmission of viruses, bacteria, and parasites to food by way of improperly washed hands is a major contributing factor in the spread of foodborne illnesses. Field observers have assessed compliance with hand washing regulations, yet few studies have included consideration of frequency and methods used by sectors of the food service industry or have included benchmarks for hand washing. Five 3-h observation periods of employee (n = 80) hand washing behaviors during menu production, service, and cleaning were conducted in 16 food service operations for a total of 240 h of direct observation. Four operations from each of four sectors of the retail food service industry participated in the study: assisted living for the elderly, childcare, restaurants, and schools. A validated observation form, based on 2005 Food Code guidelines, was used by two trained researchers. Researchers noted when hands should have been washed, when hands were washed, and how hands were washed. Overall compliance with Food Code recommendations for frequency during production, service, and cleaning phases ranged from 5% in restaurants to 33% in assisted living facilities. Procedural compliance rates also were low. Proposed benchmarks for the number of times hand washing should occur by each employee for each sector of food service during each phase of operation are seven times per hour for assisted living, nine times per hour for childcare, 29 times per hour for restaurants, and 11 times per hour for schools. These benchmarks are high, especially for restaurant employees. Implementation would mean lost productivity and potential for dermatitis; thus, active managerial control over work assignments is needed. These benchmarks can be used for training and to guide employee hand washing behaviors.

  12. Soil washing results for mixed waste pond soils at Hanford

    International Nuclear Information System (INIS)

    Gerber, M.A.; Freeman, H.D.; Baker, E.G.; Riemath, W.F.

    1991-01-01

    Soil washing technology was assessed as a means for remediating soil contaminated with mixed wastes primarily composed of heavy metals and radionuclides. The soils at the US Department of Energy's Hanford Site are considered suitable for soil washing because of their relatively low quantities of silt and clay. However, in a limited number of soil washing experiments using soils from different locations in the north pond of the 300 Area, the degree of decontamination achieved for the coarse fraction of the soil varied considerably. Part of this variation appears to be due to the presence of a discrete layer of contaminated sediment found in some of the samples

  13. The impact of WASH-1400 on reactor safety evaluation

    International Nuclear Information System (INIS)

    Tanguy, P.Y.

    1976-01-01

    Trends in reactor safety evaluation in France following the publication of WASH-1400 (the Rasmussen Report) are presented. What is called 'the meteorite case' is first schematically presented as follows: WASH-1400 shows nuclear risk equivalent to meteorite risk and reasonable corrections cannot make many orders of magnitude, consequently present safety rules are adequate. The very impact of WASH-1400 on safety approach is then discussed as for: assistance to deterministic safety analysis, introduction of probabilistic safety criteria, acceptable level of risk, and the use of results in research and reactor operating experience

  14. Cross contamination of Escherichia coli O157:H7 between lettuce and wash water during home-scale washing.

    Science.gov (United States)

    Jensen, Dane A; Friedrich, Loretta M; Harris, Linda J; Danyluk, Michelle D; Schaffner, Donald W

    2015-04-01

    Lettuce and leafy greens have been implicated in multiple foodborne disease outbreaks. This study quantifies cross contamination between lettuce pieces in a small-scale home environment. A five-strain cocktail of relevant Escherichia coli O157:H7 strains was used. Bacterial transfer between single inoculated lettuce leaf pieces to 10 non-inoculated lettuce leaf pieces that were washed in a stainless steel bowl of water for 30 s, 1 min, 2 min, and 5 min was quantified. Regardless of washing time, the wash water became contaminated with 90-99% of bacteria originally present on the inoculated lettuce leaf piece. The E. coli O157:H7 concentration on initially inoculated leaf pieces was reduced ∼ 2 log CFU. Each initially uncontaminated lettuce leaf piece had ∼ 1% of the E. coli O157:H7 from the inoculated lettuce piece transferred to it after washing, with more transfer occurring during the shortest (30 s) and longest (5 min) wash times. In all cases the log percent transfer rates were essentially normally distributed. In all scenarios, most of the E. coli O157:H7 (90-99%) transferred from the inoculated lettuce pieces to the wash water. Washing with plain tap water reduces levels of E. coli O157:H7 on the inoculated lettuce leaf pieces, but also spreads contamination to previously uncontaminated leaf pieces. Copyright © 2014 Elsevier Ltd. All rights reserved.

  15. The influence of sodium-polyacrilic macromolecular chain length to the powder detergents secondary washing performances

    Directory of Open Access Journals (Sweden)

    Milojević Vladimir S.

    2013-01-01

    Full Text Available In order to investigate the influence of sodium-polyacrylate polymer as a co-builder in addition to the carbonate/zeolite builders in detergent builder system, secondary washing performances of powder laundry detergent containing equal percentage of sodium polyacrylate with the different weight average molar mass, Mw, have been examined. The value of the degree of whiteness, elongation at break, and total residue content are the most important secondary washing performances that significantly depend on sodium polyacrylates efficiency used as crystal inhibitors, stabilizers for suspended soil, and agents for soil redisposition prevention on fabric surface. The values of the whiteness and elongation at break for cotton fabrics increase with the increase of average weight molecular mass, Mw, up to the value of 70000 g/mol, while in the case of further increase of weight average molar mass up to the 250000 g/mol value of these characteristics begin to decline. The values of the total residue content after combustion indicate an increase in its content with the increase of weight average molar mass of 3000 to 70000 g/mol, while the highest value has been reached in the sample of detergent containing sodiumpolyacrilic with the weight average molar mass of 250000 g/mol. All detergent samples show no significant dependence of the secondary washing characteristics on the number of washing cycles.

  16. Washing enhanced electrokinetic remediation for removal cadmium from real contaminated soil

    International Nuclear Information System (INIS)

    Giannis, Apostolos; Gidarakos, Evangelos

    2005-01-01

    The main objective of this study is to evaluate the combination of electrokinetic remediation and soil washing technology in order to remove cadmium from contaminated soil. This paper presents the results of an experimental research undertaken to evaluate different washing and purging solutions to enhance the removal of cadmium from a real contaminated soil during electrokinetic remediation. Two different experimental modules were applied in the laboratory. Soil was saturated with tap water, while acetic and hydrochloric acids, as well as ethylenediaminetetraacetic acid (EDTA) were used as purging solutions in the first module. Results show that there was a decrease of cadmium concentration near anode, but a significant increase in the middle of the cell, due to the increasing pH. Citric, nitric and acetic acids were used for soil washing and purging solutions in the second module. In this case, an 85% reduction of cadmium concentration was achieved. Therefore, results indicate that soil pH and washing solutions are the most important factors in governing the dissolution and/or desorption of Cd in a soil system under electrical fields

  17. Remediation of Nitrobenzene Contaminated Soil by Combining Surfactant Enhanced Soil Washing and Effluent Oxidation with Persulfate

    Science.gov (United States)

    Yan, Jingchun; Gao, Weiguo; Qian, Linbo; Han, Lu; Chen, Yun; Chen, Mengfang

    2015-01-01

    The combination of surfactant enhanced soil washing and degradation of nitrobenzene (NB) in effluent with persulfate was investigated to remediate NB contaminated soil. Aqueous solution of sodium dodecylbenzenesulfonate (SDBS, 24.0 mmol L-1) was used at a given mass ratio of solution to soil (20:1) to extract NB contaminated soil (47.3 mg kg-1), resulting in NB desorption removal efficient of 76.8%. The washing effluent was treated in Fe2+/persulfate and Fe2+/H2O2 systems successively. The degradation removal of NB was 97.9%, being much higher than that of SDBS (51.6%) with addition of 40.0 mmol L-1 Fe2+ and 40.0 mmol L-1 persulfate after 15 min reaction. The preferential degradation was related to the lone pair electron of generated SO4•−, which preferably removes electrons from aromatic parts of NB over long alkyl chains of SDBS through hydrogen abstraction reactions. No preferential degradation was observed in •OH based oxidation because of its hydrogen abstraction or addition mechanism. The sustained SDBS could be reused for washing the contaminated soil. The combination of the effective surfactant-enhanced washing and the preferential degradation of NB with Fe2+/persulfate provide a useful option to remediate NB contaminated soil. PMID:26266532

  18. Mercury distribution and lipid oxidation in fish muscle: Effects of washing and isoelectric protein precipitation

    Science.gov (United States)

    Gong, Y.; Krabbenhoft, D.P.; Ren, L.; Egelandsdal, B.; Richards, M.P.

    2011-01-01

    Nearly all the mercury (Hg) in whole muscle from whitefish (Coregonus clupeaformis) and walleye (Sander vitreus) was present as methyl mercury (MeHg). The Hg content in whole muscle from whitefish and walleye was 0.04-0.09 and 0.14-0.81 ppm, respectively. The myofibril fraction contained approximately three-fourths of the Hg in whitefish and walleye whole muscle. The sarcoplasmic protein fraction (e.g., press juice) was the next most abundant source of Hg. Isolated myosin, triacylglycerols, and cellular membranes contained the least Hg. Protein isolates prepared by pH shifting in the presence of citric acid did not decrease Hg levels. Addition of cysteine during washing decreased the Hg content in washed muscle probably through the interaction of the sulfhydryl group in cysteine with MeHg. Primary and secondary lipid oxidation products were lower during 2 ??C storage in isolates prepared by pH shifting compared to those of washed or unwashed mince from whole muscle. This was attributed to removing some of the cellular membranes by pH shifting. Washing the mince accelerated lipid peroxide formation but decreased secondary lipid oxidation products compared to that of the unwashed mince. This suggested that there was a lipid hydroperoxide generating system that was active upon dilution of aqueous antioxidants and pro-oxidants. ?? 2011 American Chemical Society.

  19. Hygienic status assessment of dish washing waters, utensils, hands ...

    African Journals Online (AJOL)

    Hygienic status assessment of dish washing waters, utensils, hands and pieces of money from street food processing sites in Ouagadougou (Burkina Faso). N Barro, AR Bello, A Savadogo, CAT Ouattara, AJ Iiboudo, AS Traoré ...

  20. SOIL WASHING TREATABILITY TESTS FOR PESTICIDE- CONTAMINATED SOIL

    Science.gov (United States)

    The 1987 Sand Creek Operable Unit 5 record of decision (ROD) identified soil washing as the selected technology to remediate soils contaminated with high levels of organochlorine pesticides, herbicides, and metals. Initial treatability tests conducted to assess the applicability...

  1. Overview of JGC soil washing and site stabilization (SWSS) concept

    International Nuclear Information System (INIS)

    Goetsch, S.; Fujimura, Y.; Sauda, K.; Yagi, T.; Suzuki, K.

    1991-01-01

    The JGC Soil Washing and Site Stabilization (SWSS) concept is to wash heavy metal and uranium-contaminated soils using well demonstrated techniques, and to follow that process with its innovative stabilization process, to fix the remaining contaminates within a stable matrix. In addition, the solution used to wash the soil is stripped of contaminates, so that it can be reused. This process reduces the total amount of wastes generated from washing the soil, since not only can the solution be reused, but often the extracted contaminates can be recovered for industrial use. The stabilization portion of the concept is based on a family of proprietary fixing agents which can render the remaining contaminates insoluble. These agents are significantly different from other (generally silicate) agents used for stabilizing contaminated soils in that they appear to bond more strongly to heavy metal contaminants than the silicate-based reagents, resulting in improved leach-rate performance when combined with bentonite or portland cement stabilization

  2. Why Is Hand Washing So Important? (For Parents)

    Science.gov (United States)

    ... hand washing a rule for everyone, especially: before eating and cooking after using the bathroom after cleaning around the house after touching animals, including family pets before and after visiting or ...

  3. Little Puerco Wash-Catalpa Canyon Floodplain Management Study

    Data.gov (United States)

    Earth Data Analysis Center, University of New Mexico — The City of Gallup requested the Soil Conservation Service, through the McKinley Soil and Water Conservation District, to conduct a study of the Little Puerco Wash...

  4. Selected Hydrologic Data for Sand Cove Wash, Washington County, Utah

    National Research Council Canada - National Science Library

    Norton, Aaron; Susong, David D

    2004-01-01

    .... Hydrologic data collected in this study are described and listed in this report. Six boreholes were drilled in Sand Cove Wash to determine the vertical and spatial distribution of the alluvial deposits and their hydrologic...

  5. Documentation of a decision framework to support enhanced sludge washing

    International Nuclear Information System (INIS)

    Brothers, A.J.

    1995-01-01

    This document describes a proposed decision model that, if developed to its fullest, can provide a wide range of analysis options and insights to pretreatment/sludge washing alternatives. A recent decision has been made to terminate this work

  6. Influence of selected washing treatments and drying temperatures ...

    African Journals Online (AJOL)

    Influence of selected washing treatments and drying temperatures on ... with regard to the optimal retention of the crude protein and fat levels of the dried dagaa. ... are accessible to most of the households involved in dried fish processing.

  7. Membrane processes for the reuse of car washing wastewater

    OpenAIRE

    Deniz Uçar

    2018-01-01

    This study investigates alternative treatments of car wash effluents. The car wash wastewater was treated by settling, filtration, and membrane filtration processes. During settling, total solid concentration decreased rapidly within the first 2 hours and then remained constant. Chemical oxygen demand (COD) and conductivity were decreased by 10% and 4%, respectively. After settling, wastewater was filtered throughout a 100 μm filter. It was found that filtration had a negligible effect on COD...

  8. Purification of crude biodiesel using dry washing and membrane technologies

    OpenAIRE

    Atadashi, I.M.

    2015-01-01

    Purification of crude biodiesel is mandatory for the fuel to meet the strict international standard specifications for biodiesel. Therefore, this paper carefully analyzed recently published literatures which deal with the purification of biodiesel. As such, dry washing technologies and the most recent membrane biodiesel purification process have been thoroughly examined. Although purification of biodiesel using dry washing process involving magnesol and ion exchange resins provides high-quali...

  9. Chlorides behavior in raw fly ash washing experiments

    International Nuclear Information System (INIS)

    Zhu Fenfen; Takaoka, Masaki; Oshita, Kazuyuki; Kitajima, Yoshinori; Inada, Yasuhiro; Morisawa, Shinsuke; Tsuno, Hiroshi

    2010-01-01

    Chloride in fly ash from municipal solid waste incinerators (MSWIs) is one of the obstructive substances in recycling fly ash as building materials. As a result, we have to understand the behavior of chlorides in recycling process, such as washing. In this study, we used X-ray absorption near edge structure (XANES) and X-ray diffraction (XRD) to study the chloride behavior in washed residue of raw fly ash (RFA). We found that a combination of XRD and XANES, which is to use XRD to identify the situation of some compounds first and then process XANES data, was an effective way to explain the chlorides behavior in washing process. Approximately 15% of the chlorine in RFA was in the form of NaCl, 10% was in the form of KCl, 51% was CaCl 2 , and the remainder was in the form of Friedel's salt. In washing experiments not only the mole percentage but also the amount of soluble chlorides including NaCl, KCl and CaCl 2 decreases quickly with the increase of liquid to solid (L/S) ratio or washing frequency. However, those of insoluble chlorides decrease slower. Moreover, Friedel's salt and its related compound (11CaO.7Al 2 O 3 .CaCl 2 ) were reliable standards for the insoluble chlorides in RFA, which are strongly related to CaCl 2 . Washing of RFA promoted the release of insoluble chlorides, most of which were in the form of CaCl 2 .

  10. A wash fluid for drilling into a field

    Energy Technology Data Exchange (ETDEWEB)

    Belyakov, V M; Badzhurak, R F; Koptelova, Ye K; Rogovoy, V K; Sapozhnikov, N G

    1979-01-18

    A wash fluid is proposed, used in drilling wells in water and a content of 3-5% by weight starch products. To speed up destruction of the starch products, to the fluid are added amylolytic enzymes in the amount of 0.01-0.1 percent by weight of the starch products' weight. To lower the use of starch products, up to 3% clay can be added to the fluid. The wash fluid is prepared directly at the work site. Dry powder of modified starch is mixed with cold water until a colloidal solution is obtained. Such a wash fluid preserves the required structural-mechanical properties for 3-5 days, which ensures prompt drilling into the waterbearing layer and installation of the filter. Then, during the work process, 5-6 hours before the moment required for lowering the viscosity, to the wash fluid is added the amylolytic enzyme; under its influence, the starch molecules split up, and the viscosity drops sharply. Using this wash fluid enables a reduction in well construction times from the beginning of drilling to the end of development of the water-bearing layer, and a rise in outputs and well service lives by reducing sedimentation of the water-bearing formation and elimination of down times during work required while waiting for destruction of the starch wash fluid under natural conditions.

  11. Cold or hot wash: Technological choices, cultural change, and their impact on clothes-washing energy use in China

    International Nuclear Information System (INIS)

    Lin, Jiang; Iyer, Maithili

    2007-01-01

    Usage pattern of clothes washing (and clothes washers) are strongly related to local cultural practices. Such practices have led to the development of distinctive clothes-washing technologies in the US, Europe, and Japan. In emerging markets such as China, several types of technologies often co-exist. Some use less energy but more water (the impeller type), and some use more energy but less water (the horizontal axis type). The competition between different technologies is thought to lead to better consumer choices. However, it could also lead to changes in clothes-washing habits-from cold to hot wash, and therefore to much higher energy use. This paper examines the standard development process in China to illustrate that adoption of foreign technologies and technical standards, if not carefully calibrated to the local cultural practices, could have unintended consequences for energy use and environment

  12. Bench-scale enhanced sludge washing and gravity settling of Hanford Tank C-106 Sludge

    International Nuclear Information System (INIS)

    Brooks, K.P.; Myers, R.L.; Rappe, K.G.

    1997-01-01

    This report summarizes the results of a bench-scale sludge pretreatment demonstration of the Hanford baseline flowsheet using liter-quantities of sludge from Hanford Site single-shell tank 241-C-106 (tank C-106). The leached and washed sludge from these tests provided Envelope D material for the contractors supporting Tank Waste Remediation System (TWRS) Privatization. Pretreatment of the sludge included enhanced sludge washing and gravity settling tests and providing scale-up data for both these unit operations. Initial and final solids as well as decanted supernatants from each step of the process were analyzed chemically and radiochemically. The results of this work were compared to those of Lumetta et al. (1996a) who performed a similar experiment with 15 grams of C-106, sludge. A summary of the results are shown in Table S.1. Of the major nonradioactive components, those that were significantly removed with enhanced sludge washing included aluminum (31%), chromium (49%), sodium (57%), and phosphorus (35%). Of the radioactive components, a significant amount of 137 Cs (49%) were removed during the enhanced sludge wash. Only a very small fraction of the remaining radionuclides were removed, including 90 Sr (0.4%) and TRU elements (1.5%). These results are consistent with those of the screening test. All of the supernatants (both individually and as a blend) removed from these washing steps, once vitrified as LLW glasses (at 20 wt% Na 2 O), would be less than NRC Class C in TRU elements and less than NRC Class B in 90 Sr

  13. Effect of water-washing on the co-removal of chlorine and heavy metals in air pollution control residue from MSW incineration.

    Science.gov (United States)

    Yang, Zhenzhou; Tian, Sicong; Ji, Ru; Liu, Lili; Wang, Xidong; Zhang, Zuotai

    2017-10-01

    The present study systemically investigated the effect of a water-washing process on the removal of harmful chlorides, sulfates, and heavy metals in the air pollution control (APC) residue from municipal solid wastes incineration (MSWI), for sake of a better reuse and disposal of this kind of waste. In addition, the kinetic study was conducted to reveal the releasing mechanism of relevant element in the residue. The results show that, over 70wt.% of chlorides and nearly 25wt.% of sulfates in the residue could be removed by water washing. Based on an economical consideration, the optimal operation conditions for water washing of APC residue was at liquid/solid (L/S) ratio of 3mL:1g and extracting time of 5min. As expected, the concentrations of Co, Cr, Fe, Ni, V and Cu in the washing effluent increased with time during the washing process. However, the extracting regime differs among different heavy metals. The concentrations of Ba and Mn increased firstly but declined afterwards, and concentrations of Pb and Zn gradually declined while Cd and As kept constant with the increase of extracting time. It is worth mentioning that the bubbling of CO 2 into the washing effluent is promisingly effective for a further removal of Pb, Cu and Zn. Furthermore, kinetic study of the water washing process reveals that the extracting of heavy metals during water washing follows a second-order model. Copyright © 2017 Elsevier Ltd. All rights reserved.

  14. Washing technology development for gravel contaminated with uranium

    Energy Technology Data Exchange (ETDEWEB)

    Park, Uk Ryang; Kim, Gye Nam; Kim, Seung Soo; Kim, Wan Suk; Moon, Jai Kwon [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2013-10-15

    The soil washing method has a short decontamination time and is economical. In addition, methods including phytoremediation, solidification/stabilization and bioremediation exist. Phytoremediation and bioremediation are economical, but have low remedial efficiency. In addition, bioremediation causes washing wastewater because it requires a washing process for the separation of microorganisms from the soils. In addition, solidification/stabilization is a commonly used methods, but eventually increases the volume of wastes. As mentioned above, many researches involved in the decontamination of radioactively contaminated soils have been actively processed. On the other hand, researches for decontaminating radioactively contaminated gravels are not being currently processed. In this study, we performed basic experiments using decontamination methods to decontaminate radioactively contaminated gravel. First, we measured the concentration of uranium in gravel included in uranium-contaminated soils and performed a washing experiment to monitor the tendency of uranium removal. In addition, when managing gravel with a low uranium-decontamination rate, we tried to satisfy the radioactivity concentration criteria for self-disposal in the wastes (0.4Bq/g or less) by performing a washing experiment after only a physical crushing process. We performed washing experiments to satisfy the radioactivity concentration criteria for self-disposal (0.4 Bq/g or less) in gravel included in radioactively contaminated soil. We performed washing experiments for gravel whose initial average concentration of uranium was 1.3Bq/g. In addition, the average concentration of uranium was 0.8Bq/g. Too increase the decontamination rate, we crushed the gravel with a jaw crusher and performed the washing experiments. The results were similar to the results without crushing. In addition, it was determined that the smaller the size of the gravel particles, the more efficient the uranium decontamination

  15. Hand washing in operating room: a procedural comparison

    Directory of Open Access Journals (Sweden)

    Alessia Stilo

    2016-09-01

    Full Text Available BACKGROUND Hand washing has been considered a measure of personal hygiene for centuries and it is known that an improper hand hygiene by healthcare workers is responsible for about 40% of nosocomial infections. Therefore, surgical hand preparation is a critical element for healthcare safety in order to reduce microbial contamination of  surgical wound in case of non detected break of the gloves. The aim of our study is to evaluate the efficacy three antiseptics: Povi-iodine scrub; EPG (Ethanol, Hydrogen Peroxide, Glycerol, recommended by WHO, and common marseille soap type in a liquid formulation. METHODS It was designed a randomized, double-blind, single-center study conducted in the University Hospital of Messina, from January to June 2013. We asked operators to put the fingertips of their right hand (if not left-handed for one minute on the PCA medium, before washing with the three types of antiseptics, and after washing and drying. Drying was made using sterile gauzes or disposable wipes. Then, we measured the number of colony forming units per mL (CFU/mL and calculated the percentage of microbial load reduction. RESULTS 211 samples have been considered for statistical analysis: in 42 samples, in fact, initial microbial load was lower than after washing. Washing with EPG reduced CFU/ml from  a mean of 38,9 to 4,1 (86,5% reduction, washing with povi-iodine scrub from 59,55 to 12,9 (75,9% reduction and washing with Marseille soap from 47,26 to 12,7 (64,3% reduction. CONCLUSIONS Our study shows that washing with EPG has superior efficacy in CFU reduction. Antiseptic hand washing, however, cannot be considered the only measure to reduce infections: the anomaly of some results (initial microbial load lower than after washing  demonstrates that drying is an essential phase in the presurgical preparation. Therefore, hand hygiene must be part of a more complex strategy of surveillance and control of nosocomial infections

  16. EBR-II Primary Tank Wash-Water Alternatives Evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Demmer, R. L.; Heintzelman, J. B.; Merservey, R. H.; Squires, L. N.

    2008-05-01

    The EBR-II reactor at Idaho National Laboratory was a liquid sodium metal cooled reactor that operated for 30 years. It was shut down in 1994; the fuel was removed by 1996; and the bulk of sodium metal coolant was removed from the reactor by 2001. Approximately 1100 kg of residual sodium remained in the primary system after draining the bulk sodium. To stabilize the remaining sodium, both the primary and secondary systems were treated with a purge of moist carbon dioxide. Most of the residual sodium reacted with the carbon dioxide and water vapor to form a passivation layer of primarily sodium bicarbonate. The passivation treatment was stopped in 2005 and the primary system is maintained under a blanket of dry carbon dioxide. Approximately 670 kg of sodium metal remains in the primary system in locations that were inaccessible to passivation treatment or in pools of sodium that were too deep for complete penetration of the passivation treatment. The EBR-II reactor was permitted by the Idaho Department of Environmental Quality (DEQ) in 2002 under a RCRA permit that requires removal of all remaining sodium in the primary and secondary systems by 2022. The proposed baseline closure method would remove the large components from the primary tank, fill the primary system with water, react the remaining sodium with the water and dissolve the reaction products in the wash water. This method would generate a minimum of 100,000 gallons of caustic, liquid, low level radioactive, hazardous waste water that must be disposed of in a permitted facility. On February 19-20, 2008, a workshop was held in Idaho Falls, Idaho, to look at alternatives that could meet the RCRA permit clean closure requirements and minimize the quantity of hazardous waste generated by the cleanup process. The workshop convened a panel of national and international sodium cleanup specialists, subject matter experts from the INL, and the EBR-II Wash Water Project team that organized the workshop. The

  17. Minimum Additive Waste Stabilization (MAWS), Phase I: Soil washing final report

    International Nuclear Information System (INIS)

    1995-08-01

    As a result of the U.S. Department of Energy's environmental restoration and technology development activities, GTS Duratek, Inc., and its subcontractors have demonstrated an integrated thermal waste treatment system at Fernald, OH, as part the Minimum Additive Waste Stabilization (MAWS) Program. Specifically, MAWS integrates soil washing, vitrification of mixed waste streams, and ion exchange to recycle and remediate process water to achieve, through a synergistic effect, a reduction in waste volume, increased waste loading, and production of a durable, leach-resistant, stable waste form suitable for disposal. This report summarizes the results of the demonstration/testing of the soil washing component of the MAWS system installed at Fernald (Plant 9). The soil washing system was designed to (1) process contaminated soil at a rate of 0.25 cubic yards per hour; (2) reduce overall waste volume and provide consistent-quality silica sand and contaminant concentrates as raw material for vitrification; and (3) release clean soil with uranium levels below 35 pCi/g. Volume reductions expected ranged from 50-80 percent; the actual volume reduction achieved during the demonstration reached 66.5 percent. The activity level of clean soil was reduced to as low as 6 pCi/g from an initial average soil activity level of 17.6 pCi/g (the highest initial level of soil provided for testing was 41 pCi/g). Although the throughput of the soil washing system was inconsistent throughout the testing period, the system was online for sufficient periods to conclude that a rate equivalent to 0.25 cubic yards per hour was achieved

  18. Instrumental neutron activation analysis of human hair and related radiotracer experiments on washing and leaching

    International Nuclear Information System (INIS)

    Das, H.A.; Hoede, D.; Sloot, H.A. van der; Herber, R.F.M.

    1981-11-01

    The work done under the IAEA-contract 2440/RB is summarized. The aim was to develop a fast and reliable system for the determination of tracer elements in human head hair by instrumental neutron activation analysis (INAA) and radiotracer washing experiments. The standardized procedure for INAA was applied to hair samples collected by the Coronel Laboratory of the University of Amsterdam. The correlation between trace element contents is considered

  19. Soil washing treatability testing for rad-waste material

    International Nuclear Information System (INIS)

    Leis, K.S.; Lear, P.R.

    1997-01-01

    Soil washing treatability testing was successfully completed on soil contaminated with Ra-226 and Th-232. The objective of the soil washing study was to determine if the radiologically contaminated fraction of the soil could be separated from the bulk of the soil material. The cleanup criteria was 38 microm) fraction was allowed to settle and was washed to separate it from the highly contaminated fine (< 38 microm) fraction. The clean coarse fraction comprised 85.7% of the total solids and had less than 15 pCi/g of Ra-226 and Th-232. This material was to be disposed at a RCRA Subtitle D disposal facility. The suspended fines were flocculated and dewatered to minimize the amount of highly contaminated material produced by the soil washing. The dewatered fines would require disposal at a low-level radiological disposal facility. Mass balance calculations were made to determine production rates and chemical and equipment requirements for the full-scale soil washing treatment

  20. Towards a durability test for washing-machines.

    Science.gov (United States)

    Stamminger, Rainer; Tecchio, Paolo; Ardente, Fulvio; Mathieux, Fabrice; Niestrath, Phoebe

    2018-04-01

    Durability plays a key role in enhancing resource conservation and contributing to waste minimization. The washing-machine product group represents a relevant case study for the development of a durability test and as a potential trigger to systematically address durability in the design of products. We developed a procedure to test the durability performance of washing-machines as a main objective of this research. The research method consisted of an analysis of available durability standards and procedures to test products and components, followed by an analysis of relevant references related to frequent failures. Finally, we defined the criteria and the conditions for a repeatable, relatively fast and relevant endurance test. The durability test considered the whole product tested under conditions of stress. A series of spinning cycles with fixed imbalanced loads was run on two washing-machines to observe failures and performance changes during the test. Even though no hard failures occurred, results clearly showed that not all washing-machines can sustain such a test without abrasion or performance deterioration. However, the attempt to reproduce the stress induced on a washing-machine by carrying out a high number of pure spinning cycles with fixed loads did not allow equal testing conditions: the actions of the control procedure regarding imbalanced loads differ from machine to machine. The outcomes of this research can be used as grounds to develop standardised durability tests and to, hence, contribute to the development of future product policy measures.

  1. Treatment of car wash wastewater by UF membranes

    Science.gov (United States)

    Istirokhatun, Titik; Destianti, Puti; Hargianintya, Adenira; Oktiawan, Wiharyanto; Susanto, Heru

    2015-12-01

    The existence of car wash service facilitates car owners to remove dirt and grime from their vehicles. However, the dirt washed off vehicles as well as the cleaning materials themselves may be harmful to the environment if they are not properly managed and discharged. Many technologies have been proposed to treat car wash wastewater such as coagulation flocculation, tricking filter and flocculation-flotation. Nevertheless, these technologies have low efficiency to eliminate oil and small organic compounds. Ultrafiltration (UF) membranes were used in this study to treat car wash wastewater. This study investigated the performance of UF membranes under various pressures to remove COD, oil and grease, and also turbidity from car wash waste water. The membrane performance was examined by investigation of permeate flux and membrane rejection. The results meet the standard of environmental regulation and it is possible to be reused. The highest rejection was shown by PES10 (polyethersulfone 10 kDa) in 1 bar operation with complete rejection for both turbidity and oil and grace and 95% rejection for COD.

  2. A novel washing algorithm for underarm stain removal

    Science.gov (United States)

    Acikgoz Tufan, H.; Gocek, I.; Sahin, U. K.; Erdem, I.

    2017-10-01

    After contacting with human sweat which comprise around 27% sebum, anti-perspirants comprising aluminium chloride or its compounds form a jel-like structure whose solubility in water is very poor. In daily use, this jel-like structure closes sweat pores and hinders wetting of skin by sweat. However, when in contact with garments, they form yellowish stains at the underarm of the garments. These stains are very hard to remove with regular machine washing. In this study, first of all, we focused on understanding and simulating such stain formation on the garments. Two alternative procedures are offered to form jel-like structures. On both procedures, commercially available spray or deo-stick type anti-perspirants, standard acidic and basic sweat solutions and artificial sebum are used to form jel-like structures, and they are applied on fabric in order to get hard stains. Secondly, after simulation of the stain on the fabric, we put our efforts on developing a washing algorithm specifically designed for removal of underarm stains. Eight alternative washing algorithms are offered with varying washing temperature, amounts of detergent, and pre-stain removal procedures. Better algorithm is selected by comparison of Tristimulus Y values after washing.

  3. [Microbiological characteristics of selected liquid soaps for hands washing].

    Science.gov (United States)

    Tyski, Stefan; Bocian, Ewa; Zawistowska, Anna; Mrówka, Agnieszka; Kruszewska, Hanna; Grzybowska, Wanda; Zareba, Tomasz

    2013-01-01

    microorganisms character - bacteria dies quicker then fungi. The special attention should be given to washing, cleaning and disinfection of preparation dispensing systems, to avoid microbial contamination of product doses applied directly on the hands. It should be emphasized that only formulations containing antimicrobial agents in an appropriate amount, eliminate microorganisms from the skin surface fast and effectively. In case of hygienic and surgical procedures following the standardized manner in order to obtain required reduction rate of microorganisms in a short time - only products complying with appropriate EN standards are suitable. For these puroposes, the popular "liquid soaps" should not be used.

  4. Computer Simulation of Bound Component Washing To Minimize Processing Costs

    Directory of Open Access Journals (Sweden)

    Dagmar Janáčová

    2011-11-01

    Full Text Available In this paper we focused on the optimization of the washing processes because many technological processes are characterizedby large consumption of water, electrical energy and auxiliary chemicals mainly. For this reason it is very important to deal withthem. For the optimization of process of washing it is possible to set up an access of the indirect modeling that is based on make-up ofmathematical models coming out of study of the physical operation mechanism. The process is diffusion character it is characterizedby the value of diffusion effective coefficient and so called structure power of the removing item to the solid phase. The mentionedparameters belong to input data that are appropriate for the automatic control of washing process.

  5. Soil washing results for mixed waste pond soils at Hanford

    International Nuclear Information System (INIS)

    Gerber, M.A.

    1991-09-01

    Soil washing technology was assessed as a means for remediating soil contaminated with mixed wastes primarily composed of heavy metals and radionuclides. The soils at the US Department of Energy's Hanford Site are considered suitable for soil washing because of their relatively low quantities of silt and clay. However, in a limited number of soil washing experiments using soils from different locations in the north pond of the 300 Area, the degree of decontamination achieved for the coarse fraction of the soil varied considerably. Part of this variation appears to be due to the presence of a discrete layer of contaminated sediment found in some of the samples. 7 refs., 2 figs., 4 tabs

  6. Gravity and magnetic study of Yucca Wash, southwest Nevada

    International Nuclear Information System (INIS)

    Langenheim, V.E.; Ponce, D.A.; Oliver, H.W.; Sikora, R.F.

    1993-01-01

    Gravity and ground magnetic data were collected along five traverses across and one traverse along Yucca Wash in the southwest quadrant of the Nevada Test Site. Two additional ground magnetic profiles were collected approximately 100 m to either side of the longitudinal profile. These data do not indicate major vertical offsets greater than 100 m using a density contrast of 0.2 to 0.3 g/cm 3 along the proposed Yucca Wash fault. A broad magnetic high coincides with the location of the hydrologic gradient. Density profiling, a technique used to determine the average density of small topographic features, suggests that the density of near-surface material in the vicinity of Yucca Wash is about 2.0 g/cm 3

  7. Dry washing: the solution for contaminated liquid effluent releases

    International Nuclear Information System (INIS)

    L'homme, D.; Trambouze, P.

    1998-01-01

    The release of wash water used for contaminated garments poses an ever-increasing problem on nuclear sites. Even though the radioactivity is low, it mixes with organic compounds, thus polluting a large quantity of liquid effluents. In many cases, several thousands of m 3 /year per nuclear site are produced, which at times represents more than 30% of the volume of total releases. The conventional dry cleaning process is not a viable option, given that repeated washing cause clothes to fade and the odors are rot removed completely. In order to eliminate releases, STMI has developed, after several years of research with the Technological University of Compiegne, France, a solvent dry washing process for garments used in the nuclear industry. (author)

  8. Chlorides behavior in raw fly ash washing experiments.

    Science.gov (United States)

    Zhu, Fenfen; Takaoka, Masaki; Oshita, Kazuyuki; Kitajima, Yoshinori; Inada, Yasuhiro; Morisawa, Shinsuke; Tsuno, Hiroshi

    2010-06-15

    Chloride in fly ash from municipal solid waste incinerators (MSWIs) is one of the obstructive substances in recycling fly ash as building materials. As a result, we have to understand the behavior of chlorides in recycling process, such as washing. In this study, we used X-ray absorption near edge structure (XANES) and X-ray diffraction (XRD) to study the chloride behavior in washed residue of raw fly ash (RFA). We found that a combination of XRD and XANES, which is to use XRD to identify the situation of some compounds first and then process XANES data, was an effective way to explain the chlorides behavior in washing process. Approximately 15% of the chlorine in RFA was in the form of NaCl, 10% was in the form of KCl, 51% was CaCl(2), and the remainder was in the form of Friedel's salt. In washing experiments not only the mole percentage but also the amount of soluble chlorides including NaCl, KCl and CaCl(2) decreases quickly with the increase of liquid to solid (L/S) ratio or washing frequency. However, those of insoluble chlorides decrease slower. Moreover, Friedel's salt and its related compound (11CaO.7Al(2)O(3).CaCl(2)) were reliable standards for the insoluble chlorides in RFA, which are strongly related to CaCl(2). Washing of RFA promoted the release of insoluble chlorides, most of which were in the form of CaCl(2). Copyright 2010 Elsevier B.V. All rights reserved.

  9. Particle Separation of Non-Decontamination Soil using Attrition and Washing

    International Nuclear Information System (INIS)

    Koo, Daeseo; Sung, Hyun-Hee; Kim, Seung-Soo; Hong, Sang Bum; Seo, Bum Kyoung; Choi, Jong-Won

    2017-01-01

    In this study, to improve the decontamination efficiency of uranium soil, a preliminary experiment on the particle separation of non-decontamination soil was carried out using attrition and washing. The characteristics of the attrition and washing system are investigated. A conditional experiment on particle separation of non-decontamination soil will be performed. A preliminary experiment on the particle separation of non-decontamination soil was carried out to improve the decontamination efficiency of uranium soil. This experiment was performed with the ratio of soil to water (1:4) for the particle separation of non-decontamination soil. The operations of all equipment such as attrition scrubber, ultrasonic reaction, vibrating screen, and hydro-cyclone were conducted and confirmed. In the future, the additional experiments will be conducted for optimal experimental condition.

  10. Effectiveness of a nonrinse, alcohol-free antiseptic hand wash.

    Science.gov (United States)

    Moadab, A; Rupley, K F; Wadhams, P

    2001-06-01

    This study evaluated the efficacy of a novel surfactant, allantoin, and benzalkonium chloride hand sanitizer using the US Food and Drug Administration's method for testing antiseptic hand washes that podiatric physicians and other health-care personnel use. The alcohol-free product, HandClens, was compared with an alcohol-based product, Purell. Independent researchers from the California College of Podiatric Medicine conducted the study using 40 volunteer students from the class of 2001. The results show that HandClens outperformed Purell and met the regulatory requirements for a hand sanitizer. Purell failed as an antimicrobial hand wash and was less effective than a control soap used in the study.

  11. Washing the patient: dignity and aesthetic values in nursing care.

    Science.gov (United States)

    Pols, Jeannette

    2013-07-01

    Dignity is a fundamental concept, but its meaning is not clear. This paper attempts to clarify the term by analysing and reconnecting two meanings of dignity: humanitas and dignitas. Humanitas refers to citizen values that protect individuals as equal to one another. Dignitas refers to aesthetic values embedded in genres of sociality that relate to differences between people. The paper explores these values by way of an empirical ethical analysis of practices of washing psychiatric patients in nursing care. Nurses legitimate the washing of reluctant patients with reference to dignity. The analysis shows the intertwinement of humanitas and dignitas that gives dignity its fundamental meaning. © 2013 John Wiley & Sons Ltd.

  12. Washing effects of limonene on pesticide residues in green peppers.

    Science.gov (United States)

    Lu, Hai-Yan; Shen, Yan; Sun, Xing; Zhu, Hong; Liu, Xian-Jin

    2013-09-01

    The presence of pesticide residues in food has caused much concern. The low health risks and environmental impacts of limonene make it a very interesting solvent for use in green chemistry. Washing effects of limonene on pesticide residues of methyl chlorpyrifos, chlorothalonil, chlorpyrifos, fenpropathrin and deltamethrin were investigated in green pepper. Results showed that washing with a low concentration of limonene for 5 min (where LOQ is limit of quantitation) caused 53.67%, limonene for 10 min produced 55.90%, limonene for 5 min was the optimal treatment for elimination of pesticide residues in green pepper, considering effect and treatment time as well as cost. © 2013 Society of Chemical Industry.

  13. Removal of heavy metals from polluted soil using the citric acid fermentation broth: a promising washing agent.

    Science.gov (United States)

    Zhang, Hongjiao; Gao, Yuntao; Xiong, Huabin

    2017-04-01

    The citric acid fermentation broth was prepared and it was employed to washing remediation of heavy metal-polluted soil. A well-defined washing effect was obtained, the removal percentages using citric acid fermentation broth are that 48.2% for Pb, 30.6% for Cu, 43.7% for Cr, and 58.4% for Cd and higher than that using citric acid solution. The kinetics of heavy metals desorption can be described by the double constant equation and Elovich equation and is a heterogeneous diffusion process. The speciation analysis shows that the citric acid fermentation broth can effectively reduce bioavailability and environmental risk of heavy metals. Spectroscopy characteristics analysis suggests that the washing method has only a small effect on the mineral composition and does not destroy the framework of soil system. Therefore, the citric acid fermentation broth is a promising washing agent and possesses a potential practical application value in the field of remediation of soils with a good washing performance.

  14. Eye wash water flow direction study: an evaluation of the effectiveness of eye wash devices with opposite directional water flow

    OpenAIRE

    Fogt JS; Jones-Jordan LA; Barr JT

    2018-01-01

    Jennifer S Fogt, Lisa A Jones-Jordan, Joseph T Barr The Ohio State University College of Optometry, Columbus, OH, USA Introduction: New designs of eye wash stations have been developed in which the direction of water flow from the fountain has been reversed, with two water streams originating nasally in both eyes and flowing toward the temporal side of each eye. No study has been done to determine the ideal direction of water flow coming from the eye wash in relation to the eye. Materials ...

  15. Wash fastness improvement of malachite green-dyed cotton fabrics ...

    Indian Academy of Sciences (India)

    Administrator

    Nano-size features of both silica and titania nanosols are predicted to enhance the wash fastness of ... The cotton fabric was obtained from traditional market and was previously tested to contain fully cellulose ..... The authors acknowledge financial support of DP2M,. Directorate General of Higher Education, Indonesia,.

  16. Hand washing practices amongst medical students in Port Harcourt ...

    African Journals Online (AJOL)

    Alasia Datonye

    Background: Hand washing with soap and water is one of ... Method: This was a descriptive cross sectional survey ... simple questionnaire exploring perceptions, attitudes and ... Many studies have shown that doctors decontaminating their hands between seeing patients ..... countries: a systematic review and meta analysis.

  17. WASH activities at two Ebola treatment units in Sierra Leone.

    Directory of Open Access Journals (Sweden)

    Michaela Mallow

    Full Text Available The 2014 outbreak of Ebola virus disease (EVD in West Africa was the largest in history. Starting in September 2014, International Medical Corps (IMC operated five Ebola treatment units (ETUs in Sierra Leone and Liberia. This paper explores how future infectious disease outbreak facilities in resource-limited settings can be planned, organized, and managed by analyzing data collected on water, sanitation, and hygiene (WASH and infection prevention control (IPC protocols.We conducted a retrospective cohort study by analyzing WASH/IPC activity data routinely recorded on paper forms or white boards at ETUs during the outbreak and later merged into a database from two IMC-run ETUs in Sierra Leone between December 2014 and December 2015.The IMC WASH/IPC database contains data from over 369 days. Our results highlight parameters key to designing and maintaining an ETU. High concentration chlorine solution usage was highly correlated with both daily patient occupancy and high-risk zone staff entries; low concentration chlorine usage was less well explained by these measures. There is high demand for laundering and disinfecting of personal protective equipment (PPE on a daily basis and approximately 1 (0-4 piece of PPE is damaged each day.Lack of standardization in the type and format of data collected at ETUs made constructing the WASH/IPC database difficult. However, the data presented here may help inform humanitarian response operations in future epidemics.

  18. Effect of washing on pesticide residues in olives.

    Science.gov (United States)

    Guardia-Rubio, M; Ayora-Cañada, M J; Ruiz-Medina, A

    2007-03-01

    The present work aims at contributing to the knowledge of the fate of 5 pesticides in olives in order to evaluate how washing may affect the presence of these residues in this fruit (and consequently in olive oil). For this purpose, olives were sprayed with commercial formulations containing the active ingredients and a series of analyses were performed for 64 d by using gas chromatography with mass spectrometric detection. Selected pesticides, ranked by their importance, were diuron, terbuthylazine, simazine, alpha-endosulfan, and beta-endosulfan. The pesticide fraction, which was not removable from olives by washing, increased with time after treatment until their degradation started at week 6. Washing performed 1 d after treatment was the most effective in reducing residues, especially for simazine. Consequently, the washing step performed in olive mills could be effective in removing those herbicide residues present in olives as a consequence of contact with contaminated soil for a short time. This happens when olives are dropped and harvested off the ground by means of brushes or suction equipment.

  19. Removal of uranium from gravel using soil washing method

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Ilgook; Kim, Kye-Nam; Kim, Seung-Soo; Choi, Jong-Won [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2015-10-15

    The development of nuclear technology has led to increasing radioactive waste containing uranium being released and disposed in the nuclear sites. Fine grained soils with a size of less than 4 mm are normally decontaminated using soil washing and electro-kinetic technologies. However, there have been few studies on the decontamination of gravels with a size of more than 4 mm. Therefore, it is necessary to study the decontamination of gravel contaminated with radionuclides. The main objective of the present study on soil washing was to define the optimal condition for acid treatment of uranium-polluted gravel. In this study, soil washing method was applied to remove uranium from gravel. The gravel was crushed and classified as particle sizes. The gravel particles were treated with sulfuric acid in a shaking incubator at 60 .deg. C and 150 rpm for 3 h. The optimal particle size of gravel for soil washing in removal of uranium was between 0.45 and 2.0 mm.

  20. FOCUS ON HAND WASHING Yakubu Tahir Maigari Departm

    African Journals Online (AJOL)

    HP

    2014-10-24

    Oct 24, 2014 ... Management and Social Sciences, Federal University Kashere,. Gombe State ... Peace can also be maintained with fellow human beings through ... talent and skill to build a mighty ship with which he and his people took .... One important aspect of Islamic rituals where washing of hands is prominent is ...

  1. Radioactive demonstration of the ''late wash'' Precipitate Hydrolysis Process

    International Nuclear Information System (INIS)

    Bibler, N.E.; Ferrara, D.M.; Ha, B.C.

    1992-01-01

    This report presents results of the radioactive demonstration of the DWPF Precipitate Hydrolysis Process as it would occur in the ''late wash'' flowsheet in the absence of hydroxylamine nitrate. Radioactive precipitate containing Cs-137 from the April, 1983, in-tank precipitation demonstration in Tank 48 was used for these tests

  2. All You Have to Do is Wash Your Hands

    Centers for Disease Control (CDC) Podcasts

    2009-03-26

    This CDC Kidtastics podcast teaches children how and when to wash their hands properly.  Created: 3/26/2009 by National Center for Zoonotic, Vector-Borne, and Enteric Diseases (NCZVED).   Date Released: 3/26/2009.

  3. Effectiveness Of Different House-Hold Hand Washing Agents On ...

    African Journals Online (AJOL)

    Hand hygiene is a very important procedure in infection control. Washing agents commonly in use were investigated for their effectiveness in reducing hand floral and cotton towel was used as drying agent. Agents studied include; water alone, carex soap, dettol, and imperial leather. The hands were inoculated (deliberate ...

  4. An overview of the Department of Energy's soil washing workshop

    International Nuclear Information System (INIS)

    1991-09-01

    The Soil Washing Workshop was convened in Las Vegas, Nevada, on August 28--29, 1990 at the request of C.W. Frank, Associate Director, Office of Technology Development, US Department of Energy (DOE). The purpose of the workshop was to determine the status of existing soil washing technologies and their applicability to specific soil contamination problems at DOE sites and at Superfund sites of the US Environmental Protection Agency (EPA). From the workshop deliberations, a course of action would be recommended in developing soil washing technologies. Presentations were given describing the soil contamination problems at various DOE sites. The factors addressed for each site included: type of contamination (organic, heavy metals, radionuclides, etc.), sources of contamination (leaking tanks, ponds, soil columns, pipes, etc.), types of soils that are contaminated, magnitude of the problem, current site activities (remediation), other considerations that impact the use of soil washing technology (e.g., environmental, site policies, etc.), and regulations and standards the sites are required to meet. Major findings and presentations of the workshop are presented

  5. Comparative studies on dyeing rate migration and wash fastness ...

    African Journals Online (AJOL)

    Migration and diffusion properties of synthesized azo dyes from 2-aminothiazole derivatives applied on commercial grade undyed cellulose acetate (CA) and cellulose triacetate (CTA) were investigated using dyeing conditions of 2% on weight of fabric (owf), 50:1 liquor ratio and subjected to ISO3 and ISO4 standard wash ...

  6. Design and Construction of a Computer Controlled Clothes Washing ...

    African Journals Online (AJOL)

    MICHAEL

    The search for easier and highly efficient ways of washing clothes ... This would help to reduce the running cost. .... It was only necessary to connect to the 8 data lines and the ... is actually a step further into complete automation of the clothes ...

  7. Distillery spent wash: Treatment technologies and potential applications

    International Nuclear Information System (INIS)

    Mohana, Sarayu; Acharya, Bhavik K.; Madamwar, Datta

    2009-01-01

    Distillery spent wash is the unwanted residual liquid waste generated during alcohol production and pollution caused by it is one of the most critical environmental issue. Despite standards imposed on effluent quality, untreated or partially treated effluent very often finds access to watercourses. The distillery wastewater with its characteristic unpleasant odor poses a serious threat to the water quality in several regions around the globe. The ever-increasing generation of distillery spent wash on the one hand and stringent legislative regulations of its disposal on the other has stimulated the need for developing new technologies to process this effluent efficiently and economically. A number of clean up technologies have been put into practice and novel bioremediation approaches for treatment of distillery spent wash are being worked out. Potential microbial (anaerobic and aerobic) as well as physicochemical processes as feasible remediation technologies to combat environmental pollution are being explored. An emerging field in distillery waste management is exploiting its nutritive potential for production of various high value compounds. This review presents an overview of the pollution problems caused by distillery spent wash, the technologies employed globally for its treatment and its alternative use in various biotechnological sectors

  8. Hand washing practices and the occurrence of enteropathogenic ...

    African Journals Online (AJOL)

    ... levels of compliance to hand washing and related this to the occurrence of infectious bacteria in the test population. A questionnaire which contained information on bio-demographic characteristics and hand hygiene practices was applied to 100 individuals in the study population. Microbiological samples were obtained, ...

  9. Assessment of washing procedure for determination some of ...

    African Journals Online (AJOL)

    This study was proposed to assess the suitability of washing technique to distinguish between airborne and soil borne several metal contaminants. For this reason, six plant species which grew under Mobarakeh Steel Company emissions were selected. Aluminum, iron, nickel, manganese, zinc, copper and lead ...

  10. Natural attenuation of NDMA precursors in an urban, wastewater-dominated wash.

    Science.gov (United States)

    Woods, Gwen C; Dickenson, Eric R V

    2016-02-01

    N-Nitrosodimethylamine (NDMA) is a disinfection by-product (DBP) that is potentially carcinogenic and has been found to occur in drinking water treatment systems impacted with treated wastewater. A major gap in NDMA research is an understanding of the persistence of wastewater-derived precursors within the natural environment. This research sought to fill this knowledge gap by surveying NDMA precursors across the length of a wastewater effluent-dominated wash. Significant precursor reduction (17%) was found to occur from introduction into the wash to a point 9 h downstream. This reduction translates into a half-life of roughly 32 h for bulk NDMA precursors. Further laboratory experiments examining rates of photolysis, biodegradation and loss to sediments, illustrated that both photolytic and biological degradation were effective removal mechanisms for NDMA precursors. Loss to sediments that were acquired from the wash did not appear to reduce NDMA precursors in the water column, although a control conducted with DI water provided evidence that significant NDMA precursors could be released from autoclaved sediments (suggesting that sorption does occur). Microbial experiments revealed that microbes associated with sediments were much more effective at degrading precursors than microbes within the water column. Overall, this study demonstrated that natural processes are capable of attenuating NDMA precursors relatively quickly within the environment, and that utilities might benefit from maximizing source water residency time in the environment, prior to introduction into treatment plants. Copyright © 2015 Elsevier Ltd. All rights reserved.

  11. Pulsed-plasma gas-discharge inactivation of microbial pathogens in chilled poultry wash water.

    Science.gov (United States)

    Rowan, N J; Espie, S; Harrower, J; Anderson, J G; Marsili, L; MacGregor, S J

    2007-12-01

    A pulsed-plasma gas-discharge (PPGD) system was developed for the novel decontamination of chilled poultry wash water. Treatment of poultry wash water in the plasma generation chamber for up to 24 s at 4 degrees C reduced Escherichia coli NCTC 9001, Campylobacter jejuni ATCC 33560, Campylobacter coli ATCC 33559, Listeria monocytogenes NCTC 9863, Salmonella enterica serovar Enteritidis ATCC 4931, and S. enterica serovar Typhimurium ATCC 14028 populations to non-detectable levels ( or = 3 log CFU/ml) in recalcitrant B. cereus NCTC 11145 endospore numbers within 30 s, the level of endospore reduction was dependent on the nature of the sparged gas used in the plasma treatments. Scanning electron microscopy revealed that significant damage occurred at the cellular level in PPGD-treated test organisms. This electrotechnology delivers energy in intense ultrashort bursts, generating products such as ozone, UV light, acoustic and shock waves, and pulsed electric fields that have multiple bactericidal properties. This technology offers an exciting complementary or alternative approach for treating raw poultry wash water and for preventing cross-contamination in processing environments.

  12. Watershed wash-off of atmospherically deposited radionuclides: a review of normalized entrainment coefficients

    International Nuclear Information System (INIS)

    Garcia-Sanchez, L.; Konoplev, A.V.

    2009-01-01

    Radionuclide wash-off is the transport of activity by flowing water over the soil surface (runoff). To complete existing reviews on long-term removal rates, this paper focuses on short-term wash-off fluxes, quantified in the literature by soil-runoff transfer factors called normalized liquid and solid entrainment coefficients (noted K l *, K s *). Compiled data concerned essentially 137 Cs and 90 Sr wash-off measured under simulated rainfalls on small experimental plots after Chernobyl fallout in the exclusion zone. K l * and K s * values span approximately one order of magnitude. Their validity is limited to a season, and their representativeness is limited by restricted studied situations, notably dominant unsoluble forms in fallout, light soils and intense rainfalls. Formulas based on a simplified representation of the soil-runoff system were proposed to generalize the existing values for other conditions. However, their implementation requires a more systematic compilation of the available information, including decisive influence factors such as the fraction of exchangeable form, distribution coefficient, suspended matter enrichment ratio. Entrainment coefficients K l * and K s * were mathematically related to the transfer function approach. The proposed relationships proved their complementarity in terms of time support and captured fluctuations. Both approaches should be used in assessments to estimate average fluxes and their variability.

  13. Characteristics and settling behaviour of particles from blast furnace flue gas washing.

    Science.gov (United States)

    Kiventerä, Jenni; Leiviskä, Tiina; Keski-Ruismäki, Kirsi; Tanskanen, Juha

    2016-05-01

    A lot of particles from iron-making are removed with blast furnace off-gas and routed to the gas cleaning system. As water is used for cleaning the gas, the produced wash water contains a large amount of particles such as valuable Fe and C. However, the presence of zinc prevents recycling. In addition, the high amount of calcium results in uncontrolled scaling. Therefore, the properties of the wash water from scrubber and sludge, from the Finnish metal industry (SSAB Raahe), were evaluated in this study. Size fractionation of wash water revealed that Fe, Zn, Al, Mn, V, Cr and Cd appeared mainly in the larger fractions (>1.2 μm) and Na, Mg, Si, Ni, K, Cu and As appeared mainly in the smaller fractions (<1.2 μm) or in dissolved form. Calcium was found both in the larger fractions and dissolved (∼60 mg/L). Most of the particles in wash water were included in the 1.2-10 μm particle size and were settled effectively. However, a clear benefit was observed when using a chemical to enhance particle settling. In comparison to 2.5 h of settling without chemical, the turbidity was further decreased by about 94%, iron 85% and zinc 50%. Coagulation-flocculation experiments indicated that both low and high molecular weight cationic polymers could provide excellent purification results in terms of turbidity. Calcium should be removed by other methods. The particles in sludge were mostly in the 2-4 μm or 10-20 μm fractions. Further sludge settling resulted in high solids removal. Copyright © 2016 Elsevier Ltd. All rights reserved.

  14. Performance of a Small-scale Treatment Wetland for Treatment of Landscaping Wash Water

    Science.gov (United States)

    Thompson, R. J.; Fayed, E.; Fish, W.

    2011-12-01

    A large number of lawn mowers and related equipment must be cleaned each day by commercial landscaping operations and state and local highway maintenance crews. Washing these devices produces wastewater that contains high amounts of organic matter and potentially problematic nutrients, as well as oil and grease and other chemicals and metals that come from the machinery itself. Dirty water washes off the mowers, flows off the pavement and into nearby storm drains without any kind of treatment. A better idea would be to collect such wastewater, retain it in an appropriate catchment such as an engineered wetland where natural processes could break down any pollutants in the wash water, and allow the water to naturally evaporate or percolate into the soil where it could recharge ground water resources safely. This research examines the performance of a small-scale treatment wetland tailored to remove nitrogen from landscaping wash water by incorporating both aerobic and anaerobic phases. Contaminants are analyzed through physical and chemical methods. Both methods involve collection of samples, followed by standardized, validated analytical laboratory tests for measuring total solids, total kjeldahl nitrogen, nitrates, total and dissolved phosphorus, COD, BOD, oil and grease, and metals (Zn and Cu). High levels of total solids, total kjeldahl nitrogen, nitrates, total and dissolved phosphorus, COD, BOD, oil and grease are found. Zinc and copper levels are low. Wetland treatment removes 99% total solids, 77% total kjeldahl nitrogen, 100% nitrates, 94% total phosphorus, 86% dissolved phosphorus, 94% COD, 97% BOD, and 76% oil and grease. The results will be a critical step towards developing a sustainable low-energy system for treating such wastewater that could be used by private landscaping companies and government agencies.

  15. Qualification testing and full-scale demonstration of titanium-treated zeolite for sludge wash processing

    Energy Technology Data Exchange (ETDEWEB)

    Dalton, W.J.

    1997-06-30

    Titanium-treated zeolite is a new ion-exchange material that is a variation of UOP (formerly Union Carbide) IONSIV IE-96 zeolite (IE-96) that has been treated with an aqueous titanium solution in a proprietary process. IE-96 zeolite, without the titanium treatment, has been used since 1988 in the West Valley Demonstration Project`s (WVDP) Supernatant Treatment System (STS) ion-exchange columns to remove Cs-137 from the liquid supernatant solution. The titanium-treated zeolite (TIE-96) was developed by Battelle-Pacific Northwest Laboratory (PNL). Following successful lab-scale testing of the PNL-prepared TIE-96, UOP was selected as a commercial supplier of the TIE-96 zeolite. Extensive laboratory tests conducted by both the WVDP and PNL indicate that the TIE-96 will successfully remove comparable quantities of Cs-137 from Tank 8D-2 high-level radioactive liquid as was done previously with IE-96. In addition to removing Cs-137, TIE-96 also removes trace quantities of Pu, as well as Sr-90, from the liquid being processed over a wide range of operating conditions: temperature, pH, and dilution. The exact mechanism responsible for the Pu removal is not fully understood. However, the Pu that is removed by the TIE-96 remains on the ion-exchange column under anticipated sludge wash processing conditions. From May 1988 to November 1990, the WVDP processed 560,000 gallons of liquid high-level radioactive supernatant waste stored in Tank 8D-2. Supernatant is an aqueous salt solution comprised primarily of soluble sodium salts. The second stage of the high-level waste treatment process began November 1991 with the initiation of sludge washing. Sludge washing involves the mixing of Tank 8D-2 contents, both sludge and liquid, to dissolve the sulfate salts present in the sludge. Two sludge washes were required to remove sulfates from the sludge.

  16. Environmental Impacts Of Zirab Coal Washing Plant, Mazandaran, Iran

    Science.gov (United States)

    Moore, F.; Esmaeili, A.

    2009-04-01

    Extraction and beneficiation operations associated with coal mining increase the rate of chemical reaction of waste material to air and water media. Zirab coal washing plant is located on the bank of the Cherat stream in Mazandaran province, Iran. coal Mined from central Alborz coalfield mines is not suitable for use in Iranian Steel Corporation. Hence, coal ash content is reduced by physical and chemical processes in this plant. These processes leave a large quantity of liquid and solid wastes that accumulate in waste dump and tailing dam. sediment and water samples taken from Sheshrudbar and Cherat streams and also from Talar river show high concentration of Cd, Mo and As in water samples of coal washing plant and the associated drainage. Eh-pH diagrams revealed the chemical species of elements in water. The enrichment factor and geoaccumulation index show that Cd, Hg, Mo and V are enriched in bottom sediments of the coal washing plant and decrease with increasing distance from the plant. Sequential extraction analysis Results of three sediment samples of Cherat stream show that silicate bound is the major phase in samples taken before and after the plant, but adjacent to the plant, organic bound is dominant. The high concentration of Cd and Mo in the water soluble phase, is noticeable and may result in high mobility and bioavailability of these elements. Mann-Whitney and Wilcoxon tests on six samples, before and after the coal washing plant support the obtained results. Keywords: Zirab; coal washing plant; Sequential extraction analysis; Mann-whitney; Wilcoxon; Enrichment factor; Geoaccumulation index.

  17. 'If an Eye Is Washed Properly, It Means It Would See Clearly': A Mixed Methods Study of Face Washing Knowledge, Attitudes, and Behaviors in Rural Ethiopia.

    Directory of Open Access Journals (Sweden)

    Kristen Aiemjoy

    2016-10-01

    Full Text Available Face cleanliness is a core component of the SAFE (Surgery, Antibiotics, Facial cleanliness, and Environmental improvements strategy for trachoma control. Understanding knowledge, attitudes, and behaviors related to face washing may be helpful for designing effective interventions for improving facial cleanliness.In April 2014, a mixed methods study including focus groups and a quantitative cross-sectional study was conducted in the East Gojjam zone of the Amhara region of Ethiopia. Participants were asked about face washing practices, motivations for face washing, use of soap (which may reduce bacterial load, and fly control strategies.Overall, both knowledge and reported practice of face washing was high. Participants reported they knew that washing their own face and their children's faces daily was important for hygiene and infection control. Although participants reported high knowledge of the importance of soap for face washing, quantitative data revealed strong variations by community in the use of soap for face washing, ranging from 4.4% to 82.2% of households reporting using soap for face washing. Cost and forgetfulness were cited as barriers to the use of soap for face washing. Keeping flies from landing on children was a commonly cited motivator for regular face washing, as was trachoma prevention.Interventions aiming to improve facial cleanliness for trachoma prevention should focus on habit formation (to address forgetfulness and address barriers to the use of soap, such as reducing cost. Interventions that focus solely on improving knowledge may not be effective for changing face-washing behaviors.

  18. A reliable procedure for decontamination before thawing of human specimens cryostored in liquid nitrogen: three washes with sterile liquid nitrogen (SLN2).

    Science.gov (United States)

    Parmegiani, Lodovico; Accorsi, Antonio; Bernardi, Silvia; Arnone, Alessandra; Cognigni, Graciela Estela; Filicori, Marco

    2012-10-01

    To report a washing procedure, to be performed as frozen specimens are taken out of cryobanks, to minimize the risk of hypothetical culture contamination during thawing. Basic research. Private assisted reproduction center. Two batches of liquid nitrogen (LN(2)) were experimentally contaminated, one with bacteria (Pseudomonas aeruginosa, Escherichia coli, Stenotrophomonas maltophilia) and the other with fungi (Aspergillus niger). Two hundred thirty-two of the most common human gamete/embryo vitrification carriers (Cryotop, Cryoleaf, Cryopette) were immersed in the contaminated LN(2) (117 in the bacteria and 25 in the fungi-contaminated LN(2)). The carriers were tested microbiologically, one group without washing (control) and the other after three subsequent washings in certified ultraviolet sterile liquid nitrogen (SLN(2)). The carriers were randomly allocated to the "three-wash procedure" (three-wash group, 142 carriers) or "no-wash" (control group, 90 carriers) using a specific software tool. Assessment of microorganism growth. In the no-wash control group, 78.6% of the carriers were contaminated by the bacteria and 100% by the fungi. No carriers were found to be contaminated, either by bacteria or fungi, after the three-wash procedure. The three-wash procedure with SLN(2) produced an efficient decontamination of carriers in extreme experimental conditions. For this reason, this procedure could be routinely performed in IVF laboratories for safe thawing of human specimens that are cryostored in nonhermetical cryocontainers, particularly in the case of open or single-straw closed vitrification systems. Copyright © 2012 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.

  19. Release of synthetic microplastic plastic fibres from domestic washing machines: Effects of fabric type and washing conditions.

    Science.gov (United States)

    Napper, Imogen E; Thompson, Richard C

    2016-11-15

    Washing clothes made from synthetic materials has been identified as a potentially important source of microscopic fibres to the environment. This study examined the release of fibres from polyester, polyester-cotton blend and acrylic fabrics. These fabrics were laundered under various conditions of temperature, detergent and conditioner. Fibres from waste effluent were examined and the mass, abundance and fibre size compared between treatments. Average fibre size ranged between 11.9 and 17.7μm in diameter, and 5.0 and 7.8mm in length. Polyester-cotton fabric consistently shed significantly fewer fibres than either polyester or acrylic. However, fibre release varied according to wash treatment with various complex interactions. We estimate over 700,000 fibres could be released from an average 6kg wash load of acrylic fabric. As fibres have been reported in effluent from sewage treatment plants, our data indicates fibres released by washing of clothing could be an important source of microplastics to aquatic habitats. Copyright © 2016 Elsevier Ltd. All rights reserved.

  20. The suitability of EIT to estimate EELV in a clinical trial compared to oxygen wash-in/wash-out technique.

    Science.gov (United States)

    Karsten, Jan; Meier, Torsten; Iblher, Peter; Schindler, Angela; Paarmann, Hauke; Heinze, Hermann

    2014-02-01

    Open endotracheal suctioning procedure (OSP) and recruitment manoeuvre (RM) are known to induce severe alterations of end-expiratory lung volume (EELV). We hypothesised that EIT lung volumes lack clinical validity. We studied the suitability of EIT to estimate EELV compared to oxygen wash-in/wash-out technique. Fifty-four postoperative cardiac surgery patients were enrolled and received standardized ventilation and OSP. Patients were randomized into two groups receiving either RM after suctioning (group RM) or no RM (group NRM). Measurements were conducted at the following time points: Baseline (T1), after suctioning (T2), after RM or NRM (T3), and 15 and 30 min after T3 (T4 and T5). We measured EELV using the oxygen wash-in/wash-out technique (EELVO2) and computed EELV from EIT (EELVEIT) by the following formula: EELVEITTx,y…=EELVO2+ΔEELI×VT/ΔZ. EELVEIT values were compared with EELVO2 using Bland-Altman analysis and Pearson correlation. Limits of agreement ranged from -0.83 to 1.31 l. Pearson correlation revealed significant results. There was no significant impact of RM or NRM on EELVO2-EELVEIT relationship (p=0.21; p=0.23). During typical routine respiratory manoeuvres like endotracheal suctioning or alveolar recruitment, EELV cannot be estimated by EIT with reasonable accuracy.

  1. The source of groundwater and solutes to Many Devils Wash at a former uranium mill site in Shiprock, New Mexico

    Science.gov (United States)

    Robertson, Andrew J.; Ranalli, Anthony J.; Austin, Stephen A.; Lawlis, Bryan R.

    2016-04-21

    The Shiprock Disposal Site is the location of the former Navajo Mill (Mill), a uranium ore-processing facility, located on a terrace overlooking the San Juan River in the town of Shiprock, New Mexico. Following the closure of the Mill, all tailings and associated materials were encapsulated in a disposal cell built on top of the former Mill and tailings piles. The milling operations, conducted at the site from 1954 to 1968, created radioactive tailings and process-related wastes that are now found in the groundwater. Elevated concentrations of constituents of concern—ammonium, manganese, nitrate, selenium, strontium, sulfate, and uranium—have also been measured in groundwater seeps in the nearby Many Devils Wash arroyo, leading to the inference that these constituents originated from the Mill. These constituents have also been reported in groundwater that is associated with Mancos Shale, the bedrock that underlies the site. The objective of this report is to increase understanding of the source of water and solutes to the groundwater beneath Many Devils Wash and to establish the background concentrations for groundwater that is in contact with the Mancos Shale at the site. This report presents evidence on three working hypotheses: (1) the water and solutes in Many Devils Wash originated from the operations at the former Mill, (2) groundwater in deep aquifers is upwelling under artesian pressure to recharge the shallow groundwater beneath Many Devils Wash, and (3) the groundwater beneath Many Devils Wash originates as precipitation that infiltrates into the shallow aquifer system and discharges to Many Devils Wash in a series of springs on the east side of the wash. The solute concentrations in the shallow groundwater of Many Devils Wash would result from the interaction of the water and the Mancos Shale if the source of water was upwelling from deep aquifers or precipitation.In order to compare the groundwater from various wells to groundwater that has been

  2. Water reuse potential in truck wash using a Rotating Biological Contactor

    OpenAIRE

    Eduardo Lucas Subtil; José Carlos Mierzwa; Ivanildo Hespanhol; Raphael Rodrigues

    2016-01-01

    This study evaluated the water reuse potential for truck washing using the effluent treated by a Rotating Biological Contactor (RBC) operated in full scale. In order to evaluate the reuse potential, a mass balance was performed for the reuse system taking into account the concentration of Total Dissolved Solids as the critical contaminant. The treatment system produced an effluent with average concentration of color, turbidity, TDS and BOD5 of 45 ± 14 uC, 15 ± 6.0 NTU, 244 ± 99 mg TDS / L and...

  3. Water saving in IC wafer washing process; IC wafer senjo deno sessui taisaku

    Energy Technology Data Exchange (ETDEWEB)

    Harada, H. [Mitsubishi Corp., Tokyo (Japan); Araki, M.; Nakazawa, T.

    1997-11-30

    This paper reports features of a wafer washing technology, a new IC wafer washing process, its pure water saving effect, and a `QC washing` which has pure water saving effect in the wafer washing. Wafer washing processes generally include the SC1 process (using ammonia + hydrogen peroxide aqueous solution) purposed for removing contamination due to ultrafine particles, the SC2 process (using hydrochloric acid + hydrogen peroxide aqueous solution) purposed for removing contamination due to heavy metals, the piranha washing process (using hot sulfuric acid + hydrogen peroxide aqueous solution) purposed for removing contamination due to organic matters, and the DHF (using dilute hydrofluoric acid) purposed for removing natural oxide films. Natural oxide films are now remained as surface protection films, by which surface contamination has been reduced remarkably. A high-temperature washing chemical circulating and filtering technology developed in Japan has brought about a reform in wafer washing processes having been used previously. Spin washing is used as a water saving measure, in which washing chemicals or pure water are sprayed onto one each of wafers which is spin-rotated, allowing washing and rinsing to be made with small amount of washing chemicals and pure water. The QC washing is a method to replace tank interior with pure was as quick as possible in order to increase the rinsing effect. 7 refs., 5 figs.

  4. Purification of crude biodiesel using dry washing and membrane technologies

    Directory of Open Access Journals (Sweden)

    I.M. Atadashi

    2015-12-01

    Full Text Available Purification of crude biodiesel is mandatory for the fuel to meet the strict international standard specifications for biodiesel. Therefore, this paper carefully analyzed recently published literatures which deal with the purification of biodiesel. As such, dry washing technologies and the most recent membrane biodiesel purification process have been thoroughly examined. Although purification of biodiesel using dry washing process involving magnesol and ion exchange resins provides high-quality biodiesel fuel, considerable amount of spent absorbents is recorded, besides the skeletal knowledge on its operating process. Further, recent findings have shown that biodiesel purification using membrane technique could offer high-quality biodiesel fuel with less wastewater discharges. Thus, both researchers and industries are expected to benefit from the development of membrane technique in purifying crude biodiesel. As well biodiesel purification via membranes has been shown to be environmentally friendly. For these reasons, it is important to explore and exploit membrane technology to purify crude biodiesel.

  5. Removal of Uranium by Exchanger Resins from Soil Washing Solution

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Seung Soo; Han, G. S.; Kim, G. N.; Koo, D. S.; Jeong, J. W.; Moon, J. K. [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2015-05-15

    Uranyl ions in the acidic waste solution were sorbed on AM-resin resin with a high sorption efficiency, and desorbed from the resin by a batch-type washing with a 60 .deg. C heated 0.5 M Na{sub 2}CO{sub 3} solution. However, the uranium dissolved in the sulfuric acid solution was not sorbed onto the strong anion exchanger resins. Our group has developed a decontamination process with washing and electrokinetic methods for uranium-contaminated (U-contaminated) soil. However, this process generates a large amount of waste solution containing various metal ions. If the uranium selectively removed from the waste solution, a very small amount of the 2nd waste would be generated. Thus, selective sorption of uranium by ion exchange resins was examined in this study.

  6. COMPILATION OF LABORATORY SCALE ALUMINUM WASH AND LEACH REPORT RESULTS

    International Nuclear Information System (INIS)

    Harrington, S.J.

    2011-01-01

    This report compiles and analyzes all known wash and caustic leach laboratory studies. As further data is produced, this report will be updated. Included are aluminum mineralogical analysis results as well as a summation of the wash and leach procedures and results. Of the 177 underground storage tanks at Hanford, information was only available for five individual double-shell tanks, forty-one individual single-shell tanks (e.g. thirty-nine 100 series and two 200 series tanks), and twelve grouped tank wastes. Seven of the individual single-shell tank studies provided data for the percent of aluminum removal as a function of time for various caustic concentrations and leaching temperatures. It was determined that in most cases increased leaching temperature, caustic concentration, and leaching time leads to increased dissolution of leachable aluminum solids.

  7. COMPILATION OF LABORATORY SCALE ALUMINUM WASH AND LEACH REPORT RESULTS

    Energy Technology Data Exchange (ETDEWEB)

    HARRINGTON SJ

    2011-01-06

    This report compiles and analyzes all known wash and caustic leach laboratory studies. As further data is produced, this report will be updated. Included are aluminum mineralogical analysis results as well as a summation of the wash and leach procedures and results. Of the 177 underground storage tanks at Hanford, information was only available for five individual double-shell tanks, forty-one individual single-shell tanks (e.g. thirty-nine 100 series and two 200 series tanks), and twelve grouped tank wastes. Seven of the individual single-shell tank studies provided data for the percent of aluminum removal as a function of time for various caustic concentrations and leaching temperatures. It was determined that in most cases increased leaching temperature, caustic concentration, and leaching time leads to increased dissolution of leachable aluminum solids.

  8. Four deaths due to carbon monoxide poisoning in car washes.

    Science.gov (United States)

    Carson, H J; Stephens, P J

    1999-09-01

    In a period of 13 months, three separate incidents of lethal carbon monoxide (CO) poisoning in closed car wash bays resulted in the deaths of 4 white men aged 20 to 36 years. Each man appears to have been intoxicated with mind-altering substances, which may impair judgment, perception of outside conditions, and self-awareness. All four died in winter months. For three men, the deaths were ruled accidental, and for the remaining man, the previous deaths appear to have provided a model for suicide. Warning signs may not be effective to prevent future CO deaths in car washes because of the possible role of intoxication. Mechanical or electronic methods to prevent a bay door from closing completely may be preferable.

  9. Recovery of silver from X-ray washings

    International Nuclear Information System (INIS)

    Begum, S.; Zeb, P.A.; Sharif, Q.

    2008-01-01

    This paper presents the enhanced recovery of silver from polymers and gelatin in X-ray washings by treating with activated carbon at different temperatures and optimizing the parameters as temperature, pH and acid base concentrations. It was found that at pilot scale silver recovery increased through treatment with activated carbon and in comparison to the temperature of 20 degree C, at 50 degree C, the recovery increased from 82.57% to 94.04%. (author)

  10. Waste washing pre-treatment of municipal and special waste.

    Science.gov (United States)

    Cossu, Raffaello; Lai, Tiziana; Pivnenko, Kostyantyn

    2012-03-15

    Long-term pollution potential in landfills is mainly related to the quality of leachate. Waste can be conveniently treated prior to landfilling with an aim to minimizing future emissions. Washing of waste represents a feasible pre-treatment method focused on controlling the leachable fraction of residues and relevant impact. In this study, non-recyclable plastics originating from source segregation, mechanical-biological treated municipal solid waste (MSW), bottom ash from MSW incineration and automotive shredder residues (ASR) were treated and the removal efficiency of washing pre-treatment prior to landfilling was evaluated. Column tests were performed to simulate the behaviour of waste in landfill under aerobic and anaerobic conditions. The findings obtained revealed how waste washing treatment (WWT) allowed the leachability of contaminants from waste to be reduced. Removal rates exceeding 65% were obtained for dissolved organic carbon (DOC), chemical oxygen demand (COD) and Total Kjeldahl Nitrogen (TKN). A percentage decrease of approximately 60% was reached for the leachable fraction of chlorides, sulphates, fluoride and metals, as proved by a reduction in electric conductivity values (70%). Copyright © 2011 Elsevier B.V. All rights reserved.

  11. Hand Washing Practices Among Emergency Medical Services Providers

    Directory of Open Access Journals (Sweden)

    Joshua Bucher

    2015-10-01

    Full Text Available Introduction: Hand hygiene is an important component of infection control efforts. Our primary and secondary goals were to determine the reported rates of hand washing and stethoscope cleaning in emergency medical services (EMS workers, respectively. Methods: We designed a survey about hand hygiene practices. The survey was distributed to various national EMS organizations through e-mail. Descriptive statistics were calculated for survey items (responses on a Likert scale and subpopulations of survey respondents to identify relationships between variables. We used analysis of variance to test differences in means between the subgroups. Results: There were 1,494 responses. Overall, reported hand hygiene practices were poor among pre-hospital providers in all clinical situations. Women reported that they washed their hands more frequently than men overall, although the differences were unlikely to be clinically significant. Hygiene after invasive procedures was reported to be poor. The presence of available hand sanitizer in the ambulance did not improve reported hygiene rates but improved reported rates of cleaning the stethoscope (absolute difference 0.4, p=0.0003. Providers who brought their own sanitizer were more likely to clean their hands. Conclusion: Reported hand hygiene is poor amongst pre-hospital providers. There is a need for future intervention to improve reported performance in pre-hospital provider hand washing.

  12. Recovery of MSWI and soil washing residues as concrete aggregates.

    Science.gov (United States)

    Sorlini, Sabrina; Abbà, Alessandro; Collivignarelli, Carlo

    2011-02-01

    The aim of the present work was to study if municipal solid waste incinerator (MSWI) residues and aggregates derived from contaminated soil washing could be used as alternative aggregates for concrete production. Initially, chemical, physical and geometric characteristics (according to UNI EN 12620) of municipal solid waste incineration bottom ashes and some contaminated soils were evaluated; moreover, the pollutants release was evaluated by means of leaching tests. The results showed that the reuse of pre-treated MSWI bottom ash and washed soil is possible, either from technical or environmental point of view, while it is not possible for the raw wastes. Then, the natural aggregate was partially and totally replaced with these recycled aggregates for the production of concrete mixtures that were characterized by conventional mechanical and leaching tests. Good results were obtained using the same dosage of a high resistance cement (42.5R calcareous Portland cement instead of 32.5R); the concrete mixture containing 400 kg/m(3) of washed bottom ash and high resistance cement was classified as structural concrete (C25/30 class). Regarding the pollutants leaching, all concrete mixtures respected the limit values according to the Italian regulation. Copyright © 2010 Elsevier Ltd. All rights reserved.

  13. Status and progress in sludge washing: A pivotal pretreatment method

    International Nuclear Information System (INIS)

    Barton, W.B.; MacLean, G.T.; Meng, C.D.; Winkler, C.M.

    1995-01-01

    Separation of the bulk soluble chemical salts from the insoluble metal hydroxides and radionuclides is central to the strategy of disposing Hanford tank waste. Sludge washing and caustic leaching have been selected as the primary methods for processing the 230 million L (61,000,000 gal) of Hanford tank waste. These processes are very similar to those selected for processing waste at the West Valley Site in New York and the Savannah River Site in South Carolina. The purpose of sludge washing is to dissolve and remove the soluble salts in the waste. Leaching of the insoluble solids with caustic will be used to dissolve aluminum hydroxide and chromium hydroxide, and convert insoluble bismuth phosphate to soluble phosphate. The waste will be separated into a high-level solids fraction and a liquid fraction that can be disposed of as low-level waste after cesium removal. The washing and leaching operations involve batchwise mixing, settling, and decanting within the existing underground storage tanks

  14. Hand Washing Practices Among Emergency Medical Services Providers.

    Science.gov (United States)

    Bucher, Joshua; Donovan, Colleen; Ohman-Strickland, Pamela; McCoy, Jonathan

    2015-09-01

    Hand hygiene is an important component of infection control efforts. Our primary and secondary goals were to determine the reported rates of hand washing and stethoscope cleaning in emergency medical services (EMS) workers, respectively. We designed a survey about hand hygiene practices. The survey was distributed to various national EMS organizations through e-mail. Descriptive statistics were calculated for survey items (responses on a Likert scale) and subpopulations of survey respondents to identify relationships between variables. We used analysis of variance to test differences in means between the subgroups. There were 1,494 responses. Overall, reported hand hygiene practices were poor among pre-hospital providers in all clinical situations. Women reported that they washed their hands more frequently than men overall, although the differences were unlikely to be clinically significant. Hygiene after invasive procedures was reported to be poor. The presence of available hand sanitizer in the ambulance did not improve reported hygiene rates but improved reported rates of cleaning the stethoscope (absolute difference 0.4, p=0.0003). Providers who brought their own sanitizer were more likely to clean their hands. Reported hand hygiene is poor amongst pre-hospital providers. There is a need for future intervention to improve reported performance in pre-hospital provider hand washing.

  15. Washing of Uranium Gel Resulted from Gelation Using Ammonia

    International Nuclear Information System (INIS)

    Nurwijayadi; Bangun-Wasito; Sukarsono; Endang-Nawangsih

    2000-01-01

    Washing of uranium gel resulted from gelation using ammonia underconcentration of 1, 2.5, 3, 4 and 5 % has been carried out. The sol wasprepared by reacting uranyl nitrate, urea and HMTA at 5 o C. The resulted solwas dropped into a column containing paraffin oil at temperature of 95 o C.The resulted gel color was orange. It was simmered in a 2.5 % ammoniasolution for 24 hours. After that, the gel was washed in an ammonia solutionunder a concentration variation. The best washing process occurred at ammoniaconcentration of 2.5 % with most absorbed ion nitrate, i.e. 292.2 ppm. Theresulted true density using N 2 was about 8.3 - 8.6 g/ml, specific surfacearea using multi point BET was about 1.5 - 3.1 m 2 /g, average pore radius was22.27 -41.22 A and total pore volume was 3.55 x 10 -3 cc/g. (author)

  16. Progress in the development of the reverse osmosis process for spacecraft wash water recovery.

    Science.gov (United States)

    Pecoraro, J. N.; Podall, H. E.; Spurlock, J. M.

    1972-01-01

    Research work on ambient- and pasteurization-temperature reverse osmosis processes for wash water recovery in a spacecraft environment is reviewed, and the advantages and drawbacks of each are noted. A key requirement in each case is to provide a membrane of appropriate stability and semipermeability. Reverse osmosis systems intended for such use must also take into account the specific limitations and requirements imposed by the small volume of water to be processed and the high water recovery desired. The incorporation of advanced high-temperature membranes into specially designed modules is discussed.

  17. Wärtsilä turbocharger wash and dew point controller integration

    OpenAIRE

    Perälä, Antti

    2013-01-01

    There are two separate control cabinets used in Wärtsilä marine solutions, Turbocharger Wash Control and the Dew Point Control. The cabinets contain similar PLCs with I/O-cards needed in the system and touch screen for monitoring and controlling purposes. The purpose of the thesis was to find and implement a solution for integration of the control cabinets. The advantages of the integration are savings in material, space in the engine room and amount of work. The aim of the project was to cre...

  18. Nuclear Car Wash sensitivity in varying thicknesses of wood and steel cargo

    International Nuclear Information System (INIS)

    Church, J; Slaughter, D; Asztalos, S; Biltoft, P; Descalle, M; Hall, J; Manatt, D; Mauger, J; Norman, E; Petersen, D; Prussin, S

    2006-01-01

    The influence of incident neutron attenuation on signal strengths in the Nuclear Car Wash has been observed experimentally for both wood and steel-pipe mock cargos. Measured decay curves are presented for β-delayed high-energy γ-rays and thermalized neutrons following neutron-induced fission of HEU through varying irradiation lengths. Error rates are extracted for delayed-γ and delayed-n signals integrated to 30 seconds, assuming Gaussian distributions for the active background. The extrapolation to a field system of 1 mA deuterium current and to a 5 kg sample size is discussed

  19. 21 CFR 864.9285 - Automated cell-washing centrifuge for immuno-hematology.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Automated cell-washing centrifuge for immuno... Establishments That Manufacture Blood and Blood Products § 864.9285 Automated cell-washing centrifuge for immuno-hematology. (a) Identification. An automated cell-washing centrifuge for immuno-hematology is a device used...

  20. Bladder wash cytology, quantitative cytology, and the qualitative BTA test in patients with superficial bladder cancer

    NARCIS (Netherlands)

    van der Poel, H. G.; van Balken, M. R.; Schamhart, D. H.; Peelen, P.; de Reijke, T.; Debruyne, F. M.; Schalken, J. A.; Witjes, J. A.

    1998-01-01

    Two new methods for the detection of transitional tumor cells in bladder wash (karyometry: QUANTICYT) and voided urine material (BARD BTA test) were compared with bladder wash cytology for the prediction of histology and tumor recurrence. Bladder wash material and voided urine were sampled from 138

  1. Effect of Disinfectants on Preventing the Cross-Contamination of Pathogens in Fresh Produce Washing Water

    NARCIS (Netherlands)

    Banach, J.L.; Sampers, I.; Haute, van S.; Fels, van der H.J.

    2015-01-01

    The potential cross-contamination of pathogens between clean and contaminated produce in the washing tank is highly dependent on the water quality. Process wash water disinfectants are applied to maintain the water quality during processing. The review examines the efficacy of process wash water

  2. 40 CFR 446.10 - Applicability; description of the oil-base solvent wash paint subcategory.

    Science.gov (United States)

    2010-07-01

    ...-base solvent wash paint subcategory. 446.10 Section 446.10 Protection of Environment ENVIRONMENTAL...-Base Solvent Wash Paint Subcategory § 446.10 Applicability; description of the oil-base solvent wash... production of oil-base paint where the tank cleaning is performed using solvents. When a plant is subject to...

  3. Check experiment of the high pressure water washing technology used to the decommissioning of reactor

    International Nuclear Information System (INIS)

    Han Jianping; Hou Yongming; Fu Yunshan

    2004-01-01

    High pressure water washing technology has been widely applied in the field of the decommissioning of nuclear facilities, and it is used to wash the sump for craft conveyance, the craft workshop, the hermetic sump, and some other nuclear equipment as well. The authors have got a set of technical data correlated with high pressure water washing technology by comparing the situations between the test before and after the washing work. At the same time, authors also improve the technique on some special cases, which made the high pressure water washing technology more perfect in the field of the decommissioning of nuclear facilities. (authors)

  4. Automatic washing of hooves can help control digital dermatitis in dairy cows

    DEFF Research Database (Denmark)

    Thomsen, Peter Thorup; Kjær Ersbøll, Annette; Sørensen, Jan Tind

    2012-01-01

    washed with a water and 0.4% soap solution. In experiment 2, hooves were washed with water only. In each experiment, DD was scored in a hoof-trimming chute approximately 60 d after the start of hoof washing. Data were analyzed using a generalized linear mixed model. The outcome was the DD status of each....... In experiment 2, the odds ratio of having DD was 1.27 in the control leg compared with the washed leg. We concluded that automatic washing of hooves with water and soap can help decrease the prevalence of DD in commercial dairy herds....

  5. Leaching Behavior of Circulating Fluidised Bed MSWI Air Pollution Control Residue in Washing Process

    Directory of Open Access Journals (Sweden)

    Zhiliang Chen

    2016-09-01

    Full Text Available In this study, air pollution control (APC residue is conducted with water washing process to reduce its chloride content. A novel electrical conductivily (EC measurement method is proposed to monitor the dynamic change of chloride concentrations in leachate as well as the chloride content of the residue. The method equally applies to various washing processes with different washing time, liquid/solid ratio and washing frequency. The results show that washing effectively extracts chloride salts from APC residues, including those from circulating fluidized bed (CFB municipal solid waste incineration (MSWI. The most appropriate liquid/solid ratio and washing time in the first washing are found to be around 4 L water per kg of APC residue and 30 min, respectively, and washing twice is required to obtain maximum dissolution. The pH value is the major controlling factor of the heavy metals speciation in leachate, while chloride concentration also affects the speciation of Cd. Water washing causes no perceptible transfer of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs from the APC residue to leachate. The chloride concentration is strongly related with electrical conductivity (EC, as well as with the concentrations of calcium, sodium and potassium of washing water. Their regression analyses specify that soluble chloride salts and EC could act as an indirect indicator to monitor the change of chloride concentration and remaining chloride content, thus, contributing to the selection of the optimal washing conditions.

  6. Can washing-pretreatment eliminate the health risk of municipal solid waste incineration fly ash reuse?

    Science.gov (United States)

    Wang, Yao; Pan, Yun; Zhang, Lingen; Yue, Yang; Zhou, Jizhi; Xu, Yunfeng; Qian, Guangren

    2015-01-01

    Although the reuse of washing-pretreated MSWI fly ash bas been a hot topic, the associated risk is still an issue of great concern. The present study investigated the influence of washing-pretreatment on the total contents and bioaccessibility of heavy metals in MSWI fly ash. Furthermore, the study incorporated bioaccessibility adjustment into probabilistic risk assessment, to quantify the health risk from multi-pathway exposure to the concerned chemicals as a result of reusing washed MSWI fly ash. The results revealed that both water-washing and acid-washing process have resulted in the concentrated heavy metal content, and have reduced the bioaccessibility of heavy metals. Besides, the acid-washing process increased the cancer risk in most cases, while the effect of water-washing process was uncertain. However, both water-washing and acid-washing pretreatment could decrease the hazard index based on bioaccesilbility. Despite the uncertainties accompanying these procedures, the results indicated that, in this application scenario, only water-washing or acid-washing process cannot reduce the actual risk from all samples to acceptable level, especially for cancer risk. Copyright © 2014. Published by Elsevier Inc.

  7. Effect of different soil washing solutions on bioavailability of residual arsenic in soils and soil properties.

    Science.gov (United States)

    Im, Jinwoo; Yang, Kyung; Jho, Eun Hea; Nam, Kyoungphile

    2015-11-01

    The effect of soil washing used for arsenic (As)-contaminated soil remediation on soil properties and bioavailability of residual As in soil is receiving increasing attention due to increasing interest in conserving soil qualities after remediation. This study investigates the effect of different washing solutions on bioavailability of residual As in soils and soil properties after soil washing. Regardless of washing solutions, the sequential extraction revealed that the residual As concentrations and the amount of readily labile As in soils were reduced after soil washing. However, the bioassay tests showed that the washed soils exhibited ecotoxicological effects - lower seed germination, shoot growth, and enzyme activities - and this could largely be attributed to the acidic pH and/or excessive nutrient contents of the washed soils depending on washing solutions. Overall, this study showed that treated soils having lower levels of contaminants could still exhibit toxic effects due to changes in soil properties, which highly depended on washing solutions. This study also emphasizes that data on the As concentrations, the soil properties, and the ecotoxicological effects are necessary to properly manage the washed soils for reuses. The results of this study can, thus, be utilized to select proper post-treatment techniques for the washed soils. Copyright © 2015 Elsevier Ltd. All rights reserved.

  8. Hydraulic washing removal efficiencies of Orimulsion from rock surfaces

    International Nuclear Information System (INIS)

    Harper, J.R.; Ward, S.; Sergy, G.

    2002-01-01

    Orimulsion is a fuel alternative composed of 70 per cent bitumen in 30 per cent water. It is shipped from Venezuela to New Brunswick where it is used as fuel oil for power plants. While there have not been any major spills of Orimulsion, it is recognized that very little is known regarding the dispersal and weathering processes of Orimulsion, or the behaviour and cleanup of the product on both rocky and course sediment shorelines. For that reason, this study was conducted to determine the efficiency of hydraulic washing under different water temperatures and pressures to remove bitumen from rocky shorelines. The results of the study make it possible to assess the physical effectiveness of the method and to determine the range of effective operational parameters. The coating protocol was refined to create uniform coating of both dispersed and coalesced bitumen of rock surfaces. The use of a chemical agent for enhancing removal efficiency was also assessed. Orimulsion could reach shorelines as low concentration dispersions of bitumen particles suspended in a water column, or as a high concentration mixture of bitumen, water and air. Granite tiles were coated with uniform coatings of both dispersed and coalesced bitumen. They were then washed under different pressures, temperatures and other treatments. Temperatures of more than 40 degrees C and pressures of more than 76 kPa were needed to effectively remove the bitumen coatings. Weathering significantly increased coating tenacity for dispersed coatings, but did not affect coalesced coating tenacity. Immediate washing was found to be very effective for removing dispersed coating, but not for coalesced coating. Coating tenacity was also affected by submergence times. Pre-treatment of the coating with a dispersion called Corexit significantly improved the removal efficiencies of dispersed coatings, but not coalesced coatings. 6 refs., 10 tabs., 5 figs

  9. Geomorphic Characterization of the FortyMile Wash Alluvial Fan, Nye County, Nevada, In Support of the Yucca Mountain Project

    International Nuclear Information System (INIS)

    Cline; De Long; Pelletier; Harrington

    2005-01-01

    In the event of an unlikely volcanic eruption through the proposed high-level radioactive waste repository at Yucca Mountain, contaminated ash would be deposited in portions of the Fortymile Wash drainage basin and would subsequently be redistributed to the Fortymile Wash alluvial fan by fluvial processes. As part of an effort to quantify the transport of contaminated ash throughout the fluvial system, characterization of the Fortymile Wash alluvial fan is required, especially the spatial distribution of fluvial activity over time scales of repository operation, and the rates of radionuclide migration into different soils on the fan. The Fortymile Wash alluvial fan consists of extremely low relief terraces as old as 70 ka. By conducting soils-geomorphic mapping and correlating relative surface ages with available geochronology from the Fortymile Wash fan and adjacent piedmonts, we identified 4 distinct surfaces on the fan. Surface ages are used to predict the relative stability of different areas of the fan to fluvial activity. Pleistocene-aged surfaces are assumed to be fluvially inactive over the 10 kyr time scale, for example. Our mapping and correlation provides a map of the depozone for contaminated ash that takes into account long-term channel migration the time scales of repository operation, and it provides a geomorphic framework for predicting radionuclide dispersion rates into different soils across the fan. The standard model for vertical migration of radionuclides in soil is diffusion; therefore we used diffusion profiles derived from 137 Cs fallout to determine infiltration rates on the various geomorphic surfaces. The results show a strong inverse correlation of the geomorphic surface age and diffusivity values inferred from the 137 Cs profiles collected on the different surfaces of the fan

  10. Formulation and Assessment of a Wash-Primer Containing Lanthanum "Tannate" for Steel Temporary Protection

    Science.gov (United States)

    D'Alessandro, Oriana; Selmi, Gonzalo J.; Deyá, Cecilia; Di Sarli, Alejandro; Romagnoli, Roberto

    2018-02-01

    Tannins are polyphenols synthesized by plants and useful for the coating industry as corrosion inhibitors. In addition, lanthanum salts have a great inhibitory effect on steel corrosion. The aim of this study was to obtain lanthanum "tannate" with adequate solubility to be incorporated as the corrosion inhibitor in a wash-primer. The "tannate" was obtained from commercial "Quebracho" tannin and 0.1 M La(NO3)3. The soluble tannin was determined by the Folin-Denis reagent, while the concentration of Lanthanum was obtained by a gravimetric procedure. The protective action of "tannate" on SAE 1010 steel was evaluated by linear polarization curves and corrosion potential measurements. Lanthanum "tannate" was incorporated in a wash-primer formulation and tested by corrosion potential and ionic resistance measurements. The corrosion rate was also determined by the polarization resistance technique. Besides, the primer was incorporated in an alkyd paint system and its anticorrosion performance assessed in the salt spray cabinet and by electrochemical impedance spectroscopy. Results showed that lanthanum "tannate" primer inhibits the development of deleterious iron oxyhydroxides on the steel substrate and incorporated into a paint system had a similar behavior to the primer formulated with zinc tetroxychromate.

  11. Water reuse potential in truck wash using a Rotating Biological Contactor

    Directory of Open Access Journals (Sweden)

    Eduardo Lucas Subtil

    2016-11-01

    Full Text Available This study evaluated the water reuse potential for truck washing using the effluent treated by a Rotating Biological Contactor (RBC operated in full scale. In order to evaluate the reuse potential, a mass balance was performed for the reuse system taking into account the concentration of Total Dissolved Solids as the critical contaminant. The treatment system produced an effluent with average concentration of color, turbidity, TDS and BOD5 of 45 ± 14 uC, 15 ± 6.0 NTU, 244 ± 99 mg TDS / L and 14 ± 7.3 mg O2 / L, respectively. Based on the mass balance, and considering the TDS concentration established in NBR 13.696, if the final rinse does not use clean water, the potential for effluent reuse can reach 40%. However, if clean water is used as 30% of the total rinsing volume, it would be possible to reuse 70% of the treated effluent without compromising truck washing performance. This water reuse approach would result in an operational cost reduction of R$ 2,590.75/month.

  12. Artificial radioactivity in tide washed pastures in south west Scotland

    International Nuclear Information System (INIS)

    McKay, W.A.; Bonnett, P.J.P.; Barr, H.M.; Howorth, J.M.

    1991-01-01

    A study has been carried out to determine the impact of Sellafield discharges on the levels of radioactivity in tide washed pastures in south west Scotland. The likely areas of tidal inundations along the Nith, Urr, Dee, Fleet and Cree (including nearby Bladnoch) rivers were assessed using maps and aerials photographs. These were then visited and gamma radiation measurements taken at regular intervals to enable the external dose from anthropogenic nuclides to be estimated. A further survey followed where soil cores were taken from the areas on each river where the external dose appeared highest and analysed for a range of artificial radionuclides. The levels of 137 Cs, 134 Cs, 238 Pu, 239+240 Pu and 241 Am found, although small, were clearly in excess of the background from other sources. A habit survey was carried out to provide site specific information of tide washed pasture usage, which, with the spatial radionuclide data was used to estimate doses to appropriate critical groups. The maximum annual dose calculated to arise was 60 μSv which is less than 6% of the ICRP principal dose limit of 1 mSv. (author)

  13. Membrane processes for the reuse of car washing wastewater

    Directory of Open Access Journals (Sweden)

    Deniz Uçar

    2018-04-01

    Full Text Available This study investigates alternative treatments of car wash effluents. The car wash wastewater was treated by settling, filtration, and membrane filtration processes. During settling, total solid concentration decreased rapidly within the first 2 hours and then remained constant. Chemical oxygen demand (COD and conductivity were decreased by 10% and 4%, respectively. After settling, wastewater was filtered throughout a 100 μm filter. It was found that filtration had a negligible effect on COD removal. Finally, wastewater was filtered by four ultrafiltration membranes of varying molecular weight cutoff (MWCO (1, 5, 10 and 50 kDa and one nanofiltration membrane (NF270, MWCO = 200–400 Da. The permeate COD concentrations varied between 64.5 ± 3.2 and 85.5 ± 4.3 mg L−1 depending on UF pore size. When the NF270 nanofiltration membrane was used, the permeate COD concentration was 8.1 ± 0.4 mg L−1 corresponding to 97% removal. FeCl3 precipitation and activated carbon adsorption techniques were also applied to the retentate and 60–76% COD removals were obtained for activated carbon adsorption and FeCl3 precipitation, respectively.

  14. Selected hydrologic data from Fortymile Wash in the Yucca Mountain area, Nevada, water years 1993--94

    Energy Technology Data Exchange (ETDEWEB)

    Savard, C.S.

    1996-09-01

    The Yucca Mountain area is being evaluated by the US Department of Energy for its suitability to store high-level nuclear waste in a mined, underground repository. Hydrologic data are being collected by the US Geological Survey throughout a 150 Km{sup 2} study area about 15- Km northwest of Las Vegas in southern Nevada for site characterization studies. Ongoing hydrologic studies are investigating atmospheric precipitation, stream-flow, movement of water through the unsaturated zone, movement of water through the saturated zone, and paleohydrology. This study at Fortymile Wash involves some components of each of these studies. Fortymile Wash is an ephemeral stream near Yucca Mountain with tributaries draining the east side of Yucca Mountain and then forming a distributary system in the Amargosa Desert. An objective of the study is to determine the amount of recharge from Fortymile Wash to the ground-water flow system that has been proposed. Understanding the ground-water flow system is important because it is a possible mechanism for radionuclide migration from the repository to the accessible environment. An adequate understanding of the ground-water flow system is necessary for an evaluation of the safety issues involved in siting the potential repository.

  15. Toxicological assessment and management options for boat pressure-washing wastewater.

    Science.gov (United States)

    Gerić, Marko; Gajski, Goran; Oreščanin, Višnja; Kollar, Robert; Franekić, Jasna; Garaj-Vrhovac, Vera

    2015-04-01

    Boats are washed periodically for maintenance in order to remove biofoulants from hulls, which results in the generation of wastewater. This study aimed at evaluating the cyto/genotoxic and mutagenic properties of wastewater produced by pressure washing of boats. The chemical characterisation of this wastewater showed that Cu, Zn, V, Cr, Fe, Pb, and select organic contaminants exceeded the maximum allowable values from 1.7 up to 96 times. The wastewater produced negative effects on human lymphocytes resulting in decreased cell viability after 4 and 24h of exposure. Chromosome aberration, micronucleus, and comet assay parameters were significantly higher after 24h of exposure. At the same time, the Salmonella typhimurium test showed negative for both TA98 and TA100 strains at all of the concentrations tested. After the treatment of wastewater using electrochemical methods/ozonation during real scale treatment plant, removal rates of colour, turbidity and heavy metals ranged from 99.4% to 99.9%, while the removal of total organic carbon (TOC) and chemical oxygen demand (COD) was above 85%. This was reflected in the removal of the wastewater's cyto/genotoxicity, which was comparable to negative controls in all of the conducted tests, suggesting that such plants could be implemented in marinas to minimise human impact on marine systems. Copyright © 2015 Elsevier Inc. All rights reserved.

  16. Dye Removal From Textile Waste Water Through The Adsorption By Pumice Used In Stone Washing

    Directory of Open Access Journals (Sweden)

    Körlü Aysegül Ekmekçi

    2015-09-01

    Full Text Available Because the waste production is inevitable in almost all industries, the elimination of these wastes is a requirement in terms of environmental regulations and welfare of all the creatures in the future. In this study, the use of the waste pumice stones of a denim washing mill is intended to eliminate the pollutant by a waste material and obtain economic benefits by converting it to the adsorbent. The pollutants in the effluents obtained from three different localisations of waste water treatment system of the same factory were removed through the adsorption. The experimental studies were carried out in three different steps; characterisation of adsorbent before and after adsorption; adsorption isotherm studies and biological oxygen demand (BOD, chemical oxygen demand (COD measurements. Characterisation studies showed that the waste pumice has almost the same structural properties with unused one except the existence of some organic residues coming from washing process. The results of adsorption studies conducted at the adsorbent concentrations changing from 5 to 35 g/l revealed that the decolourisation was initial dye-concentration dependent. According to the BOD and COD measurements, the supernatants obtained at the end of adsorption could be assumed as somewhat polluted and this result indicates that the organic impurities other than indigo were also removed through the adsorption.

  17. Washing of fly ash from combustion of municipal solid waste using water as leachant; Vattentvaett av flygaska fraan avfallsfoerbraenning

    Energy Technology Data Exchange (ETDEWEB)

    Steenari, Britt-Marie; Zhao, Dongmei

    2010-03-15

    Ashes from combustion of municipal solid waste contain a large amount of minerals, salts and other metal compounds that are more or less soluble in water. The metal salts are often enriched in the fly ash which leads to a classification of the ash as hazardous waste. This makes ash management complicated and costly. Many stabilisation methods for Municipal Solid Waste Incineration (MSWI) fly ash have been developed and most of them are based on a removal of chloride and sulfate in addition to a binding of metals in less soluble forms. The aim is to avoid the common situation that the ash does not comply to leaching limit values due to release of harmless salts. The aim of this project was to investigate if a simple washing with water can remove enough of the fly ash content of chloride and sulphate so that the ash can be landfilled in a simpler and less costly way than today. The project was focused on fly ashes from the MSWI units owned by Boraas Energi och Miljoe AB and Renova AB Goeteborg, i.e. a electro filter ash from grate fired boilers at Renova and a cyclone ash from a fluid bed boiler at Boraas. The results show that the main part of the chloride content of the ashes can be removed easily, but the washing with water is less effective in the removal of sulphate. A water-to-ash ratio of 1-2 l/kg removes about 100% of chloride but only 8-16% of the sulphate content. In many cases, the leachability of sulphate increases after the washing step. This is due to the rather complex sulphate chemistry with several possible reactions taking place in the ash-water system. For both the tested ashes the high level of chloride leaching is an important factor that prevents admittance on a landfill for hazardous waste without treatment.. The leaching of certain metals, such as Pb, is also high from both ashes but in the case of the Renova fly ash this is dealt with by treatment of the ash according to the Bamberg method. After a water washing with L/S 1-2 (L/kg dry ash

  18. Effect of soil washing with only chelators or combining with ferric chloride on soil heavy metal removal and phytoavailability: Field experiments.

    Science.gov (United States)

    Guo, Xiaofang; Wei, Zebin; Wu, Qitang; Li, Chunping; Qian, Tianwei; Zheng, Wei

    2016-03-01

    In a field experiment on multi-metal contaminated soil, we investigated the efficiency of Cd, Pb, Zn, and Cu removal by only mixture of chelators (MC) or combining with FeCl3. After washing treatment, a co-cropping system was performed for heavy metals to be extracted by Sedum alfredii and to produce safe food from Zea mays. We analyzed the concentration of heavy metals in groundwater to evaluate the leashing risk of soil washing with FeCl3 and MC. Results showed that addition of FeCl3 was favorable to the removal of heavy metals in the topsoil. Metal leaching occurred mainly in rain season during the first co-cropping. The removal rates of Cd, Zn, Pb, and Cu in topsoil were 28%, 53%, 41%, and 21% with washing by FeCl3+MC after first harvest. The application of FeCl3 reduced the yield of S. alfredii and increased the metals concentration of Z. mays in first harvest. However, after amending soil, the metals concentration of Z. mays in FeCl3+MC treatment were similar to that only washing by MC. The grains and shoots of Z. mays were safe for use in feed production. Soil washing did not worsen groundwater contamination during the study period. But the concentration of Cd in groundwater was higher than the limit value of Standard concentrations for Groundwater IV. This study suggests that soil washing using FeCl3 and MC for the remediation of multi-metal contaminated soil is potential feasibility. However, the subsequent measure to improve the washed soil environment for planting crop is considered. Copyright © 2016. Published by Elsevier Ltd.

  19. Changes in soil toxicity by phosphate-aided soil washing: effect of soil characteristics, chemical forms of arsenic, and cations in washing solutions.

    Science.gov (United States)

    Jho, Eun Hea; Im, Jinwoo; Yang, Kyung; Kim, Young-Jin; Nam, Kyoungphile

    2015-01-01

    This study was set to investigate the changes in the toxicity of arsenic (As)-contaminated soils after washing with phosphate solutions. The soil samples collected from two locations (A: rice paddy and B: forest land) of a former smelter site were contaminated with a similar level of As. Soil washing (0.5 M phosphate solution for 2 h) removed 24.5% As, on average, in soil from both locations. Regardless of soil washing, Location A soil toxicities, determined using Microtox, were greater than that of Location B and this could be largely attributed to different soil particle size distribution. With soils from both locations, the changes in As chemical forms resulted in either similar or greater toxicities after washing. This emphasizes the importance of considering ecotoxicological aspects, which are likely to differ depending on soil particle size distribution and changes in As chemical forms, in addition to the total concentration based remedial goals, in producing ecotoxicologically-sound soils for reuse. In addition, calcium phosphate used as the washing solution seemed to contribute more on the toxic effects of the washed soils than potassium phosphate and ammonium phosphate. Therefore, it would be more appropriate to use potassium or ammonium phosphate than calcium phosphate for phosphate-aided soil washing of the As-contaminated soils. Copyright © 2014 Elsevier Ltd. All rights reserved.

  20. Wash functions downstream of Rho1 GTPase in a subset of Drosophila immune cell developmental migrations

    Science.gov (United States)

    Verboon, Jeffrey M.; Rahe, Travis K.; Rodriguez-Mesa, Evelyn; Parkhurst, Susan M.

    2015-01-01

    Drosophila immune cells, the hemocytes, undergo four stereotypical developmental migrations to populate the embryo, where they provide immune reconnoitering, as well as a number of non–immune-related functions necessary for proper embryogenesis. Here, we describe a role for Rho1 in one of these developmental migrations in which posteriorly located hemocytes migrate toward the head. This migration requires the interaction of Rho1 with its downstream effector Wash, a Wiskott–Aldrich syndrome family protein. Both Wash knockdown and a Rho1 transgene harboring a mutation that prevents Wash binding exhibit the same developmental migratory defect as Rho1 knockdown. Wash activates the Arp2/3 complex, whose activity is needed for this migration, whereas members of the WASH regulatory complex (SWIP, Strumpellin, and CCDC53) are not. Our results suggest a WASH complex–independent signaling pathway to regulate the cytoskeleton during a subset of hemocyte developmental migrations. PMID:25739458

  1. Closed Process of Shale Oil Recovery from Circulating Washing Water by Hydrocyclones

    Directory of Open Access Journals (Sweden)

    Yuan Huang

    2016-12-01

    Full Text Available The conventional oil recovery system in the Fushun oil shale retorting plant has a low oil recovery rate. A large quantity of fresh water is used in the system, thereby consuming a considerable amount of water and energy, as well as polluting the environment. This study aims to develop a closed process of shale oil recovery from the circulating washing water for the Fushun oil shale retorting plant. The process would increase oil yield and result in clean production. In this process, oil/water hydrocyclone groups were applied to decrease the oil content in circulating water and to simultaneously increase oil yield. The oil sludge was removed by the solid/liquid hydrocyclone groups effectively, thereby proving the smooth operation of the devices and pipes. As a result, the oil recovery rate has increased by 5.3 %, which corresponds to 230 tonnes a month.

  2. The Nuclear Car Wash: Neutron interrogation of cargo containers to detect hidden SNM

    Science.gov (United States)

    Hall, J. M.; Asztalos, S.; Biltoft, P.; Church, J.; Descalle, M.-A.; Luu, T.; Manatt, D.; Mauger, G.; Norman, E.; Petersen, D.; Pruet, J.; Prussin, S.; Slaughter, D.

    2007-08-01

    LLNL is actively involved in the development of advanced technologies for use in detecting threats in sea-going cargo containers, particularly the presence of hidden special nuclear materials (SNM). The "Nuclear Car Wash" (NCW) project presented here uses a high-energy (En ≈ 3.5-7.0 MeV) neutron probe to scan a container and then takes high-energy (Eγ ⩾ 2.5 MeV), β-delayed γ-rays emitted during the subsequent decay of any short-lived, neutron-induced fission products as a signature of fissionable material. The components of the proposed system (e.g. neutron source, gamma detectors, etc.) will be discussed along with data processing schemes, possible threat detection metrics and potential interference signals. Results from recent laboratory experiments using a prototype system at LLNL will also be presented.

  3. The Nuclear Car Wash: Neutron interrogation of cargo containers to detect hidden SNM

    International Nuclear Information System (INIS)

    Hall, J.M.; Asztalos, S.; Biltoft, P.; Church, J.; Descalle, M.-A.; Luu, T.; Manatt, D.; Mauger, G.; Norman, E.; Petersen, D.; Pruet, J.; Prussin, S.; Slaughter, D.

    2007-01-01

    LLNL is actively involved in the development of advanced technologies for use in detecting threats in sea-going cargo containers, particularly the presence of hidden special nuclear materials (SNM). The 'Nuclear Car Wash' (NCW) project presented here uses a high-energy (E n ∼ 3.5-7.0 MeV) neutron probe to scan a container and then takes high-energy (E γ ≥ 2.5 MeV), β-delayed γ-rays emitted during the subsequent decay of any short-lived, neutron-induced fission products as a signature of fissionable material. The components of the proposed system (e.g. neutron source, gamma detectors, etc.) will be discussed along with data processing schemes, possible threat detection metrics and potential interference signals. Results from recent laboratory experiments using a prototype system at LLNL will also be presented

  4. Possibilities of soil washing for decontamination at Belgoprocess

    Energy Technology Data Exchange (ETDEWEB)

    Aerts, Wouter [Belgoprocess, Dessel, Antwerp (Belgium); De Bruecker, Thomas; Lytek, Anna [DEC - DEME Environmental Contractor, Zwijndrecht, Antwerp (Belgium)

    2013-07-01

    Contaminated soils form a large part of the nuclear waste arising from decommissioning activities. The storage and disposal of these large volumes of waste is costly. For this reason techniques which can decontaminate this waste stream to free release levels are economically very interesting. A feasibility study of the possibilities of soil washing to decontaminate such soils was ordered by NIRAS/ONDRAF and performed at Belgoprocess in collaboration with DEC. Initial contamination level and particle size distributions of contaminated soils from three different sources were determined. The main isotopes detected with gamma spectrometry contained in the waste were {sup 241}Am, {sup 137}Cs, {sup 226}Ra, {sup 60}Co and {sup 232}Th. The particle size distribution revealed that more than half of the mass of the quartz sand that makes up the soil has a particle size between 125 and 212 μm. This fraction is less contaminated than the fractions containing smaller particles. However, separation of the fines fraction (< 125 μm) was not enough to achieve the free release limit. Soil attrition was tested as an extra decontamination step for the sand fraction. The removal efficiencies for the different radionuclides contained in the soil were measured. The process conditions were optimized to achieve maximum removal and a treatment method for the secondary waste coming from this process step was determined. The soil washing process was not only performed with water but also with nitric acid to assess the possibilities of a combination of a mechanical and a chemical decontamination process. Reduction efficiencies of 60-80% for the most relevant radionuclides were recorded. (authors)

  5. Chelator induced phytoextraction and in situ soil washing of Cu

    International Nuclear Information System (INIS)

    Kos, Bostjan; Lestan, Domen

    2004-01-01

    In a soil column experiment, we investigated the effect of 5 mmol kg -1 soil addition of citric acid, ethylenediamine tetraacetate (EDTA), diethylenetriamine-pentaacetate (DTPA) and [S,S]-stereoisomer of ethylenediamine-disuccinate (EDDS) on phytoextraction of Cu from a vineyard soil with 162.6 mg kg -1 Cu, into the test plant Brassica rapa var. pekinensis. We also examined the use of a horizontal permeable barrier, composed of layers of nutrient enriched sawdust and apatite, for reduction of chelator induced Cu leaching. The addition of all chelators, except citric acid, enhanced Cu mobility and caused leaching of 19.5-23% of initial total Cu from the soil column. However, Cu plant uptake did not increase accordingly; the most effective was the EDDS treatment, in which plant Cu concentration reached 37.8±1.3 mg kg -1 Cu and increased by 3.3-times over the control treatment. The addition of none of the chelators in the concentration range from 5 to 15 mmol kg -1 exerted any toxic effect on respiratory soil microorganisms. When EDDS was applied into the columns with horizontal permeable barriers, only 0.53±0.32% of the initial total Cu was leached. Cu (36.7%) was washed from the 18 cm soil layer above the barrier and accumulated in the barrier. Our results indicate that rather than for a reduction of Cu leaching during rather ineffective chelate induced Cu phytoextraction, horizontal permeable barriers could be more effective in a new remediation technique of controlled in situ soil washing of Cu with biodegradable chelates

  6. Soil Chemistry Effect on Feasibility of Cr-decontamination by Acid-Washing

    OpenAIRE

    Isoyama, Masahiro; Wada, Shin-Ichiro

    2006-01-01

    Soil washing with sample acid jas been proven to be effective for removal of cationic heavy metals from contaminated soils. Since the obsorption of anitonic heavy metals is enhanced in acidic medium, the efficiency of acid-washing may not be guaranteed for soils that are doubly contaminated with cationic and anitonic heavy metals. To evaluate the efficiensy of acid-washing, nine soils are artifically contaminated with chromate and chromium was extracted with hydrochrolic acid of 0.5 mmol L[-1...

  7. Set-up for steam generator tube bundle washing after explosion expanding the tubes

    International Nuclear Information System (INIS)

    Osipov, S.I.; Kal'nin, A.Ya.; Mazanenko, M.F.

    1985-01-01

    Set-up for steam generator tube bundle washing after the explosion expanding of tubes is described. Washing is accomplished by distillate. Steam is added to distillate for heating, and compersed air for preventing hydraulic shock. The set-up is equiped by control equipment. Set-up performances are presented. Time for one steam generator washing constitutes 8-12 h. High economic efficiency is realized due to the set-up introduction

  8. Pretreatment chemistry evaluation: Wash and leach factors for the single-shell tank waste inventory. Status report

    International Nuclear Information System (INIS)

    Colton, N.G.

    1996-09-01

    This report discusses a methodology developed to depict overall wash and leach factors for the Hanford single-shell tank (SST) inventory. The factors derived from this methodology, which is based on available partitioning data, are applicable to a composite SST inventory rather than only an assumed insoluble portion. The purpose of considering the entire inventory is to provide a more representative picture of the partitioning behavior of the analytes during envisioned waste retrieval and processing activities. The work described in this report was conducted by the Pretreatment Chemistry Evaluation task of the Tank Waste Remediation System (TWRS). The leach factors will be used to estimate the further removal of analytes, such as sodium, aluminum, phosphate, and other minor components. Wash and leach factors are given for elements expected to drive the volume of material disposed of as high-level waste (HLW)

  9. Ethanol production by Kluyveromyces marxianus IMB3 during growth on straw-supplemented whiskey distillery spent wash at 45 C

    Energy Technology Data Exchange (ETDEWEB)

    Barron, N.; Mulholland, H.; Boyle, M.; McHale, A.P. [Biotechnology Research Group, School of Applied Biological and Chemical Sciences, University of Ulster, Coleraine, Co. Londonderry, BT52 1SA (United Kingdom)

    1997-11-01

    The thermotolerant, ethanol-producing yeast strain, Kluyveromyces marxianus IMB3 was grown on media consisting of straw-supplemented distillery spent wash from The Old Bushmill`s Distillery Co. Ltd., Bushmills, Co Antrim, Northern Ireland. Media were supplemented with cellulase activity and fermentations were carried out at 45 C. When pulverized straw was used as substrate in this system at concentrations of 2, 4 and 6% (w/v), ethanol concentrations increased to maxima of 1.45, 2.2 and 3 g/l, respectively. Based on straw containing a maximum of 40% cellulose, these ethanol concentrations accounted for 36, 27 and 24% of the maximum theoretical yield, respectively. When the straw was pre-treated with NaOH and used in the spent wash containing system at concentrations of 2, 4 and 6% (w/v) ethanol, concentrations increased to maxima of 3, 6.2 and 10.5 g/l, respectively and these accounted for 75, 76 and 86% of the maximum theoretical yield. When these results are compared with previously published data relating to the use of straw in laboratory-based media, they suggest that whiskey distillery spent wash may provide an adequate medium for supplementation with complex carbohydrate and subsequent ethanol production in simultaneous saccharification and fermentation processes. (orig.) With 2 figs., 17 refs.

  10. Applicability of the Reactor Safety Study (WASH-1400) to LMFBR risk assessments

    International Nuclear Information System (INIS)

    El-Sheikh, K.A.; Feller, K.G.; Fleischer, L.; Greebler, P.; McDonald, A.; Sultan, P.; Temme, M.I.; Fullwood, R.R.

    1976-01-01

    The feasibility of applying the WASH-1400 methods and data to LMFBR risk assessment is evaluated using the following approach for a selected LMFBR: (1) Structuring the LMFBR risk assessment problem in a modular form similar to WASH-1400; (2) Comparing the predictive tools applicable to each module; (3) Comparing the dependencies among the various modules. It is concluded that the WASH-1400 applicability is limited due to LWR-LMFBR differences in operating environments and accident phenomena. WASH-1400 and LMFBR specific methods applicable to LMFBR risk assessments are indicated

  11. Coagulation-flocculation process applied to wastewaters generated in hydrocarbon-contaminated soil washing

    International Nuclear Information System (INIS)

    Torres, L. g.; Belloc, C.; Iturbe, R.; Bandala, E.

    2009-01-01

    A wastewater produced in the contaminated soil washing was treated by means of coagulation-flocculation (CF) process. the wastewater treatment in this work continued petroleum hydrocarbons, a surfactant, i. e., sodium dodecyl sulphate (SDS) as well as salts, humic acids and other constituents that were lixiviated rom the soil during the washing process. The aim of this work was to develop a process for treating the wastewaters generated when washing hydrocarbon-contaminated soils in such a way that it could be recycled to the washing process, and at the end of the cleaning up, the waters could be disposed properly. (Author)

  12. Mothers’ Hand washing Practice and Diarrhea Cases in Children under Five in Baleendah, Bandung

    Directory of Open Access Journals (Sweden)

    M Syafril Firdaus

    2015-06-01

    Full Text Available ackground: Diarrhea is a disease, especially in children, with high mortality and morbidity rate in developing countries, including Indonesia. Diarrhea can be prevented if people can apply clean and healthy behaviors, especially hand washing. Hand washing is the cheapest, simplest, and the most effective methods for prevention of diarrhea. The objective of this study is to identify the knowledge, attitude, and practice of mothers’ hand washing and diarrhea cases in children under five in Baleendah District, Bandung. Methods: A descriptive study was conducted during September−November 2012 to 210 mothers who had children (ages 12−59 months in Baleendah using rapid survey technique. The time allocated for each village was adjusted to the population proportion for each region. The data were analyzed using computer and was represented using frequency distribution. Results: This study showed that the respondents had good level of knowledge and attitude of hand washing (83.8% and 61%, respectively, but only 21% of the respondents’ practices of hand washing was in good level. Most of the respondents did not wash their hands according to the 7 steps of correct hand washing. Moreover the percentage of children with diarrhea in Baleendah was 43.8% (92 cases during the study. Conclusions: There should be dissemination of information about the benefit of washing hands with 7 steps of correct hands washing so that families can practice it and can prevent diarrhea in children under five.

  13. Ground-water recharge in Fortymile Wash near Yucca Mountain, Nevada, 1992--1993

    International Nuclear Information System (INIS)

    Savard, C.S.

    1994-01-01

    Quantification of the ground-water recharge from streamflow in the Fortymile Wash watershed will contribute to regional ground-water studies. Regional ground-water studies are an important component in the studies evaluating the ground-water flow system as a barrier to the potential migration of radionuclides from the potential underground high-level nuclear waste repository. Knowledge gained in understanding the ground-water recharge mechanisms and pathways in the Pah Canyon area, which is 10 km to the northeast of Yucca Mountain, may transfer to Yucca site specific studies. The current data collection network in Fortymile Canyon does not permit quantification of ground-water recharge, however a qualitative understanding of ground-water recharge was developed from these data

  14. Crystallization and demineralization phenomena in washed-rind cheese.

    Science.gov (United States)

    Tansman, Gil F; Kindstedt, Paul S; Hughes, John M

    2017-11-01

    This report documents an observational study of a high-moisture washed-rind cheese. Three batches of cheese were sampled on a weekly basis for 6 wk and again at wk 10. Center, under-rind, rind, and smear samples were tested for pH, moisture, and selected mineral elements. Powder x-ray diffractometry and petrographic microscopy were applied to identify and image the crystal phases. The pH of the rind increased by over 2 pH units by wk 10. The pH of the under-rind increased but remained below the rind pH, whereas the center pH decreased for most of aging and only began to rise after wk 5. Diffractograms of smear material revealed the presence of 4 crystal phases: brushite, calcite, ikaite, and struvite. The phases nucleated in succession over the course of aging, with calcite and ikaite appearing around the same time. A very small amount of brushite appeared sporadically in center and under-rind samples, but otherwise no other crystallization was observed beneath the rind. Micrographs revealed that crystals in the smear grew to over 250 μm in length by wk 10, and at least 2 different crystal phases, probably ikaite and struvite, could be differentiated by their different optical properties. The surface crystallization was accompanied by a mineral diffusion phenomenon that resulted, on average, in a 217, 95.7, and 149% increase in calcium, phosphorus, and magnesium, respectively, in the rind by wk 10. The diffusion phenomenon caused calcium, phosphorus, and magnesium to decrease, on average, by 55.0, 21.5, and 36.3%, respectively, in the center by wk 10. The present study represents the first observation of crystallization and demineralization phenomena in washed-rind cheese. The Authors. Published by the Federation of Animal Science Societies and Elsevier Inc. on behalf of the American Dairy Science Association®. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/3.0/).

  15. Revealing fate of CO2 leakage pathways in the Little Grand Wash Fault, Green River, Utah

    Science.gov (United States)

    Han, K.; Han, W. S.; Watson, Z. T.; Guyant, E.; Park, E.

    2015-12-01

    To assure long-term security of geologic carbon sequestration site, evaluation of natural CO2 leakage should be preceded before actual construction of the CO2 facility by comparing natural and artificial reservoir systems. The Little Grand Wash fault is located at the northwestern margin of the Paradox Basin and roles on a bypass of deep subsurface CO2 and brine water onto the surface, e.g., cold water geyser, CO2 spring, and surface travertine deposits. CO2 degassed out from brine at the Little Grand Wash fault zone may react with formation water and minerals while migrating through the fault conduit. Leakage observed by soil CO2 flux on the fault trace shows this ongoing transition of CO2, from supersaturated condition in deep subsurface to shallow surface equilibria. The present study aims to investigate the reactions induced by changes in hydrological and mineralogical factors inside of the fault zone. The methodology to develop site-specific geochemical model of the Little Grand Wash Fault combines calculated mechanical movements of each fluid end-member, along with chemical reactions among fluid, free CO2 gas and rock formations. Reactive transport modeling was conducted to simulate these property changes inside of the fault zone, using chemistry dataset based on 86 effluent samples of CO2 geysers, springs and in situ formation water from Entrada, Carmel, and Navajo Sandstone. Meanwhile, one- and two-dimensional models were separately developed to delineate features mentioned above. The results from the 3000-year simulation showed an appearance of self-sealing processes near the surface of the fault conduit. By tracking physicochemical changes at the depth of 15 m on the 2-dimensional model, significant changes induced by fluid mixing were indicated. Calculated rates of precipitation for calcite, illite, and pyrite showed increase in 2.6 x 10-4, 2.25 x 10-5, and 3.0 x 10-6 in mineral volume fraction at the depth of 15m, respectively. Concurrently

  16. 77 FR 8895 - Jimbilnan, Pinto Valley, Black Canyon, Eldorado, Ireteba Peaks, Nellis Wash, Spirit Mountain, and...

    Science.gov (United States)

    2012-02-15

    ..., Pinto Valley, Black Canyon, Eldorado, Ireteba Peaks, Nellis Wash, Spirit Mountain, and Bridge Canyon..., Eldorado, Ireteba Peaks, Nellis Wash, Spirit Mountain, and Bridge Canyon Wilderness Areas, Lake Mead... wilderness character; providing for reasonable use of Spirit Mountain and adjacent areas in a manner meeting...

  17. Evaluation of Resuspension from Propeller Wash in DoD Harbors

    Science.gov (United States)

    2016-05-01

    in ERDC’s Prop-Wash Tank Resuspension by propeller wash from tugboat: in-situ field data: near-bed velocity field, shear stress, critical shear...samples of sediment and water were collected prior to any resuspension event. A C14 Tractor and a slightly smaller Tiger tug boats were used in San

  18. Automated washing of FTA Card punches and PCR setup for reference samples using a LIMS-controlled Sias Xantus automated liquid handler

    DEFF Research Database (Denmark)

    Stangegaard, Michael; Olsen, Addie Nina; Frøslev, Tobias G.

    2009-01-01

    We have implemented and validated automated methods for washing FTA Card punches containing buccal samples and subsequent PCR setup using a Sias Xantus automated liquid handler. The automated methods were controlled by worklists generated by our LabWare Laboratory Information Management System...

  19. Reverse osmosis for wash water recovery in space vehicles.

    Science.gov (United States)

    Lawrence, R. W.; Saltonstall, C. W., Jr.

    1973-01-01

    Tests were carried out on both synthetic and real wash water derived from clothes laundry to determine the utility of reverse osmosis in recovering the water for recycle use. A blend membrane made from cellulose di- and triacetates, and a cross-linked cellulose acetate/methacrylate were evaluated. Both were found acceptable. A number of detergents were evaluated, including a cationic detergent, sodium dodecyl sulfate, potassium palmitate, and sodium dodecylbenzenesulfonate. The tests were all made at a temperature of 165 F to minimize microbial growth. Long-term (15 to 30 day) runs were made at 600 and 400 psi on laundry water which was pretreated either by alum addition and sand filtration or by filtration only through 0.5 micron filters. A 30-day run was made using a 2-in. diameter by 22-in. long spiral module at 400 psig with filtering as the pretreatment. The membrane fouling by colloidal matter was found to be controllable. The unit produced initially 55 gal/day and 27 gal/day after 30 days.

  20. Washing and changing uniforms: is guidance being adhered to?

    Science.gov (United States)

    Potter, Yvonne Camilla; Justham, David

    To allay public apprehension regarding the risk of nurses' uniforms transmitting healthcare-associated infections (HCAI), national and local guidelines have been issued to control use, laundry and storage. This paper aims to measure the knowledge of registered nurses (RNs) and healthcare assistants (HCAs) working within a rural NHS foundation Trust and their adherence to the local infection prevention and control (IPC) standard regarding uniforms through a Trust-wide audit. Stratified random sampling selected 597 nursing staff and 399 responded (67%) by completing a short questionnaire based on the local standard. Responses were coded and transferred to SPSS (v. 17) for analysis. The audit found that nursing staff generally adhere to the guidelines, changing their uniforms daily and immediately upon accidental soiling, and wearing plastic aprons where indicated. At home, staff normally machine-wash and then iron their uniforms at the hottest setting. Nevertheless, few observe the local direction to place their newly-laundered uniforms in protective covers. This paper recommends a re-audit to compare compliance rates with baseline figures and further research into the reasons why compliance is lacking to sanction interventions for improvement, such as providing relevant staff education and re-introducing appropriate changing facilities.

  1. Patients' Hand Washing and Reducing Hospital-Acquired Infection.

    Science.gov (United States)

    Haverstick, Stacy; Goodrich, Cara; Freeman, Regi; James, Shandra; Kullar, Rajkiran; Ahrens, Melissa

    2017-06-01

    Hand hygiene is important to prevent hospital-acquired infections. Patients' hand hygiene is just as important as hospital workers' hand hygiene. Hospital-acquired infection rates remain a concern across health centers. To improve patients' hand hygiene through the promotion and use of hand washing with soap and water, hand sanitizer, or both and improve patients' education to reduce hospital-acquired infections. In August 2013, patients in a cardiothoracic postsurgical step-down unit were provided with individual bottles of hand sanitizer. Nurses and nursing technicians provided hand hygiene education to each patient. Patients completed a 6-question survey before the intervention, at hospital discharge and 1, 2, and 3 months after the intervention. Hospital-acquired infection data were tracked monthly by infection prevention staff. Significant correlations were found between hand hygiene and rates of infection with vancomycin-resistant enterococci ( P = .003) and methicillin-resistant Staphylococcus aureus ( P = .01) after the intervention. After the implementation of hand hygiene interventions, rates of both infections declined significantly and patients reported more staff offering opportunities for and encouraging hand hygiene. This quality improvement project demonstrates that increased hand hygiene compliance by patients can influence infection rates in an adult cardiothoracic step-down unit. The decreased infection rates and increased compliance with hand hygiene among the patients may be attributed to the implementation of patient education and the increased accessibility and use of hand sanitizer. ©2017 American Association of Critical-Care Nurses.

  2. Signals and interferences in the nuclear car wash

    Science.gov (United States)

    Church, J. A.; Slaughter, D. R.; Asztalos, S.; Biltoft, P.; Descalle, M.-A.; Hall, J.; Luu, T.; Manatt, D.; Mauger, J.; Norman, E. B.; Petersen, D.; Prussin, S.

    2007-08-01

    The screening of sea-going cargo containers for highly enriched uranium (HEU) and other fissile material is a challenging problem. This is due in part to the cargo itself, which acts as an attenuator to any radiation that might signal its presence. In the nuclear car wash, β-delayed high-energy γ-rays following neutron-induced fission are utilized as this signal. The delayed γ-rays above 3 MeV are highly penetrating and have energies above natural background radiation. In addition, the half-lives of most fission products emitting γ-rays at these energies are less than 160 s, making it feasible to construct decay curves on a time scale which preserves the flow of commerce through the port. A particular goal of the project is to understand the rate of false alarms. To this end, experiments are underway to investigate possible interferences, and to understand variations in the overall γ-ray background. The experiments and preliminary results are discussed. Work performed under the auspices of the DOE by the UC LLNL W7405Eng4,UCRL-PROC-224803.

  3. Signals and interferences in the nuclear car wash

    International Nuclear Information System (INIS)

    Church, J.A.; Slaughter, D.R.; Asztalos, S.; Biltoft, P.; Descalle, M.-A.; Hall, J.; Luu, T.; Manatt, D.; Mauger, J.; Norman, E.B.; Petersen, D.; Prussin, S.

    2007-01-01

    The screening of sea-going cargo containers for highly enriched uranium (HEU) and other fissile material is a challenging problem. This is due in part to the cargo itself, which acts as an attenuator to any radiation that might signal its presence. In the nuclear car wash, β-delayed high-energy γ-rays following neutron-induced fission are utilized as this signal. The delayed γ-rays above 3 MeV are highly penetrating and have energies above natural background radiation. In addition, the half-lives of most fission products emitting γ-rays at these energies are less than 160 s, making it feasible to construct decay curves on a time scale which preserves the flow of commerce through the port. A particular goal of the project is to understand the rate of false alarms. To this end, experiments are underway to investigate possible interferences, and to understand variations in the overall γ-ray background. The experiments and preliminary results are discussed. Work performed under the auspices of the DOE by the UC LLNL W7405Eng4,UCRL-PROC-224803

  4. Washing and caustic leaching of Hanford tank sludges

    International Nuclear Information System (INIS)

    Lumetta, G.J.; Rapko, B.M.; Colton, N.G.

    1994-01-01

    Methods are being developed to treat and dispose of large volumes of radioactive wastes stored in underground tanks at the U.S. Department of Energy's Hanford Site. The wastes will be partitioned into high-level waste (HLW) and low-level waste (LLW) fractions. The HLW will be vitrified into borosilicate glass and disposed of in a geologic repository, while the LLW will be immobilized in a glass matrix and will likely be disposed of by shallow burial at the Hanford Site. The wastes must be pretreated to reduce the volume of the HLW fraction, so that vitrification and disposal costs can be minimized. The current baseline process for pretreating Hanford tank sludges is to leach the sludge under caustic conditions, then remove the solubilized components of the sludge by water washing. Tests of this method have been performed with samples taken from several different tanks at Hanford. The results of these tests are presented in terms of the composition of the sludge before and after leaching. X-ray diffraction and scanning electron microscopy coupled with electron dispersive x-ray techniques have been used to identify the phases in the untreated and treated sludges

  5. Style-based classification of Chinese ink and wash paintings

    Science.gov (United States)

    Sheng, Jiachuan; Jiang, Jianmin

    2013-09-01

    Following the fact that a large collection of ink and wash paintings (IWP) is being digitized and made available on the Internet, their automated content description, analysis, and management are attracting attention across research communities. While existing research in relevant areas is primarily focused on image processing approaches, a style-based algorithm is proposed to classify IWPs automatically by their authors. As IWPs do not have colors or even tones, the proposed algorithm applies edge detection to locate the local region and detect painting strokes to enable histogram-based feature extraction and capture of important cues to reflect the styles of different artists. Such features are then applied to drive a number of neural networks in parallel to complete the classification, and an information entropy balanced fusion is proposed to make an integrated decision for the multiple neural network classification results in which the entropy is used as a pointer to combine the global and local features. Evaluations via experiments support that the proposed algorithm achieves good performances, providing excellent potential for computerized analysis and management of IWPs.

  6. An evaluation of different soil washing solutions for remediating arsenic-contaminated soils.

    Science.gov (United States)

    Wang, Yiwen; Ma, Fujun; Zhang, Qian; Peng, Changsheng; Wu, Bin; Li, Fasheng; Gu, Qingbao

    2017-04-01

    Soil washing is a promising way to remediate arsenic-contaminated soils. Most research has mostly focused on seeking efficient extractants for removing arsenic, but not concerned with any changes in soil properties when using this technique. In this study, the removal of arsenic from a heavily contaminated soil employing different washing solutions including H 3 PO 4 , NaOH and dithionite in EDTA was conducted. Subsequently, the changes in soil physicochemical properties and phytotoxicity of each washing technique were evaluated. After washing with 2 M H 3 PO 4 , 2 M NaOH or 0.1 M dithionite in 0.1 M EDTA, the soil samples' arsenic content met the clean-up levels stipulated in China's environmental regulations. H 3 PO 4 washing decreased soil pH, Ca, Mg, Al, Fe, and Mn concentrations but increased TN and TP contents. NaOH washing increased soil pH but decreased soil TOC, TN and TP contents. Dithionite in EDTA washing reduced soil TOC, Ca, Mg, Al, Fe, Mn and TP contents. A drastic color change was observed when the soil sample was washed with H 3 PO 4 or 0.1 M dithionite in 0.1 M EDTA. After adjusting the soil pH to neutral, wheat planted in the soil sample washed by NaOH evidenced the best growth of all three treated soil samples. These results will help with selecting the best washing solution when remediating arsenic-contaminated soils in future engineering applications. Copyright © 2017 Elsevier Ltd. All rights reserved.

  7. Effect of egg washing on the cuticle quality of brown and white table eggs.

    Science.gov (United States)

    Leleu, S; Messens, W; De Reu, K; De Preter, S; Herman, L; Heyndrickx, M; De Baerdemaeker, J; Michiels, C W; Bain, M

    2011-10-01

    Egg washing is currently not permitted within the European Union, with few exceptions. This is mainly because there are concerns that cuticle damage could occur during or after the washing process, as a result of a suboptimal operation. In this study, the cuticle coverage levels of 400 washed or unwashed eggs, derived from either a brown or a white egg-laying flock at the end of lay, were compared. The eggs from older hens inherently have poorer cuticle coverage and as a result arguably constitute a greater risk to consumer safety if they are then washed. Thus, the effects of the washing procedure used in this study on cuticle quality were tested under the worst-case scenario. A standard Swedish egg washing process was used. The cuticle coverage of the eggs was assessed by a colorimeter by quantifying the color difference before and after staining with Tartrazine and Green S. The cuticle of an additional 30 eggs from each of the four groups was then visually assessed by scanning electron microscopy. The staining characteristics of the cuticle varied greatly within each group of eggs and showed that the washing process did not lead to cuticle damage. Scanning electron microscopy confirmed that there was no irreversible damage to the cuticle of the washed eggs and that it was not possible to correctly assign the treatment (washed or not) based on a visual assessment. In conclusion, no evidence could be found to suggest that the washing procedure used in this investigation irreversibly changed the quality of the cuticle.

  8. Coagulation-flocculation process applied to wastewaters generated in hydrocarbon-contaminated soil washing: Interactions among coagulant and flocculant concentrations and pH value.

    Science.gov (United States)

    Torres, Luis G; Belloc, Claudia; Vaca, Mabel; Iturbe, Rosario; Bandala, Erick R

    2009-11-01

    Wastewater produced in the contaminated soil washing was treated by means of coagulation-flocculation (CF) process. The wastewater contained petroleum hydrocarbons, a surfactant, i.e., sodium dodecyl sulfate (SDS) as well as salts, brownish organic matter and other constituents that were lixiviated from the soil during the washing process. The main goal of this work was to develop a process for treating the wastewaters generated when washing hydrocarbon-contaminated soils in such a way that it could be recycled to the washing process, and also be disposed at the end of the process properly. A second objective was to study the relationship among the coagulant and flocculant doses and the pH at which the CF process is developed, for systems where methylene blue active substances (MBAS) as well as oil and greases were present. The results for the selection of the right coagulant and flocculant type and dose, the optimum pH value for the CF process and the interactions among the three parameters are detailed along this work. The best coagulant and flocculant were FeCl(3) and Tecnifloc 998 at doses of 4,000 and 1 mg/L, correspondingly at pH of 5. These conditions gave color, turbidity, chemical oxygen demand (COD) and conductivity removals of 99.8, 99.6, 97.1 and 35%, respectively. It was concluded that it is feasible to treat the wastewaters generated in the contaminated soil washing process through CF process, and therefore, wastewaters could be recycled to the washing process or disposed to drainage.

  9. Adsorption Removal of Glycidyl Esters from Palm Oil and Oil Model Solution by Using Acid-Washed Oil Palm Wood-Based Activated Carbon: Kinetic and Mechanism Study.

    Science.gov (United States)

    Cheng, Weiwei; Liu, Guoqin; Wang, Xuede; Han, Lipeng

    2017-11-08

    Acid-washed oil palm wood-based activated carbon (OPAC) has been investigated for its potential application as a promising adsorbent in the removal of glycidyl esters (GEs) from both palm oil and oil model (hexadecane) solution. It was observed that the removal rate of GEs in palm oil was up to >95%, which was significantly higher than other adsorbents used in this study. In batch adsorption system, the adsorption efficiency and performance of acid-washed OPAC were evaluated as a function of several experimental parameters such as contact time, initial glycidyl palmitate (PGE) concentration, adsorbent dose, and temperature. The Langmuir, Freundlich, and Dubinin-Radushkevich models were used to describe the adsorption equilibrium isotherm, and the equilibrium data were fitted best by the Langmuir model. The maximum adsorption capacity of acid-washed OPAC was found to be 36.23 mg/g by using the Langmuir model. The thermodynamic analysis indicated that the adsorption of PGE on acid-washed OPAC was an endothermic and physical process in nature. The experimental data were fitted by using pseudo-first-order, pseudo-second-order, and intraparticle diffusion models. It was found that the kinetic of PGE adsorption onto acid-washed OPAC followed well the pseudo-second-order model for various initial PGE concentrations and the adsorption process was controlled by both film diffusion and intraparticle diffusion. The desorption test indicated the removal of GEs from palm oil was attributed to not only the adsorption of GEs on acid-washed OPAC, but also the degradation of GEs adsorbed at activated sites with acidic character. Furthermore, no significant difference between before and after PGE adsorption in oil quality was observed.

  10. The Design and Research on Washing Label with NFC%基于NFC的服装水洗标设计与研究

    Institute of Scientific and Technical Information of China (English)

    马天宇; 刘正东

    2017-01-01

    With the rapid development of NFC (near field communication) technology,a wash label with NFC tags was proposed to meet the requirements of digitalization of the clothing industry.It forms a clothing information system with NFC mobile phone,mobile Internet and enterprise information center.Mter experiment,the consumers can read and write NFC washing labels on their mobile phones,and obtain the clothing washing maintenance information conveniently.The NFC washing label conforms to the standards of washing requirements.The occurrence of NFC washing label has provided the physical basis for intelligent collocation recommendation and accurate directional push of consumer clothing advertising information.%随着NFC(近场通信)技术的迅速发展,以及服装行业的数字化推进,设计了一种基于NFC标签的服装水洗标.其通过与NFC手机、移动互联网、企业的信息中心等组成一个服装信息系统.经过实验,消费者通过手机读写NFC水洗标,能更加快捷方便地获取服装水洗养护信息,且NFC水洗标符合水洗标的水洗要求.NFC水洗标的出现为智能搭配推荐和对消费者服装广告信息的精确定向推送提供了数据基础.

  11. Soils washing for removal of heavy oil: Naval Air Engineering Center, Lakehurst, NJ

    International Nuclear Information System (INIS)

    Nash, J.H.; Traver, R.P.

    1991-01-01

    With the recognition that large tracts of land are currently unusable as a result of either accidental spills or past industrial practices (such as oil field development), the USEPA Office of Research and Development evaluated soil washing as an alternative remedial technology for heavy oil contaminated soil at a site located on the Naval Air Engineering Center (NAEC), Lakehurst, New Jersey. The researchers used a self-contained, 100-pound-per-hour soil washer. Electrical, pneumatic, and fluid-pumping capabilities were provided by the trailer-mounted system at a remote No. 6 type oil spill site at the Navy base. Chloroform extracts of the contaminated sandy soil recovered a 0.91 gram/milliliter, 950 centistoke viscosity, dark brown, non-PCB oil. By using a surfactant/solvent solution at ambient temperatures, contaminant levels on the soil were reduced from 3.8% (38,000 milligram/kilogram-RCRA hazardous waste designation) to as low as 0.035% (350 milligram/kilogram) oil concentration. Supplemental laboratory evaluations extending the pilot field evaluations showed at elevated temperatures (120F) that residual oil contamination was less than 0.01% (100 milligram/kilogram). This final oil concentration in the treated soil would be defined as clean under the New Jersey Environmental Cleanup and Responsibilities Act (ECRA). A continuous belt press filter was used to recover the oil in a 47% solids cake that could be used as a secondary fuel feed to a waste boiler. The wash water solution was treated and recycled permitting economical operations

  12. Internalization of Listeria monocytogenes in cantaloupes during dump tank washing and hydrocooling.

    Science.gov (United States)

    Macarisin, Dumitru; Wooten, Anna; De Jesus, Antonio; Hur, Minji; Bae, Seonjae; Patel, Jitendra; Evans, Peter; Brown, Eric; Hammack, Thomas; Chen, Yi

    2017-09-18

    Recent listeriosis outbreaks and recalls associated with cantaloupes urge for studies to understand the mechanisms of cantaloupe contamination by Listeria monocytogenes. Postharvest practices such as washing and hydrocooling were suggested to facilitate the contamination of fresh fruits by human pathogens. This study assessed the potential of L. monocytogenes internalization into cantaloupes during dump tank washing and immersion-type hydrocooling in water contaminated with L. monocytogenes. The effect of cantaloupe cultivar, water temperature, and harvesting technique on L. monocytogenes internalization was also evaluated. Full slip (cantaloupe without any residual stem) Western and Eastern cultivar cantaloupes were pre-warmed to 42°C (to imitate peak-high field temperatures of freshly harvested cantaloupes) and then immersed in water at 6°C and 18°C containing 4 and 6logCFU/ml of L. monocytogenes. Clipped (cantaloupe with short stem residues obtained by clipping the stem at harvest) Western and Eastern cantaloupes were pre-warmed to 42°C and then immersed in water at 6°C containing 6logCFU/ml of L. monocytogenes. Additionally, full slip and clipped Western cantaloupes were equilibrated to 18°C and then immersed in water at 18°C containing 6logCFU/ml of L. monocytogenes (isothermal immersion without temperature differential). Water containing L. monocytogenes infiltrated both full slip and clipped cantaloupes through the stems/stem scars and was then distributed along the vascular system in hypodermal mesocarp reaching the calyx area of the fruit. The current study demonstrated that, under experimental conditions, L. monocytogenes can internalize into cantaloupes during immersion in water contaminated by L. monocytogenes, both in the presence and absence of temperature differential, and that temperature differential moderately enhanced the internalization of L. monocytogenes. The incidence and levels of L. monocytogenes internalized in the middle

  13. Water washes and caustic leaches of sludge from Hanford Tank S-101 and water washes of sludge from Hanford Tank C-103

    International Nuclear Information System (INIS)

    Hunt, R.D.; Collins, J.L.; Chase, C.W.

    1998-07-01

    In 1993, the Department of Energy (DOE) selected the enhanced sludge washing (ESW) process as the baseline for pretreatment of Hanford tank sludges. The ESW process uses a series of water washes and caustic leaches to separate nonradioactive components such as aluminum, chromium, and phosphate from the high-level waste sludges. If the ESW process is successful, the volume of immobilized high-level waste will be significantly reduced. The tests on the sludge from Hanford Tank S-101 focused on the effects of process variables such as sodium hydroxide concentration (1 and 3 M), temperature (70 and 95 C), and leaching time (5, 24, 72, and 168 h) on the efficacy of the ESW process with realistic liquid-to-solid ratios. Another goal of this study was to evaluate the effectiveness of water washes on a sludge sample from hanford Tank C-103. The final objective of this study was to test potential process control monitors during the water washes and caustic leaches with actual sludge. Both 137 Cs activity and conductance were measured for each of the water washes and caustic leaches. Experimental procedures, a discussion of results, conclusions and recommendations are included in this report

  14. Bacterial reduction by cell salvage washing and leukocyte depletion filtration.

    Science.gov (United States)

    Waters, Jonathan H; Tuohy, Marion J; Hobson, Donna F; Procop, Gary

    2003-09-01

    Blood conservation techniques are being increasingly used because of the increased cost and lack of availability of allogeneic blood. Cell salvage offers great blood savings opportunities but is thought to be contraindicated in a number of areas (e.g., blood contaminated with bacteria). Several outcome studies have suggested the safety of this technique in trauma and colorectal surgery, but many practitioners are still hesitant to apply cell salvage in the face of frank bacterial contamination. This study was undertaken to assess the efficacy of bacterial removal when cell salvage was combined with leukocyte depletion filtration. Expired packed erythrocytes were obtained and inoculated with a fixed amount of a stock bacteria (Escherichia coli American Type Culture Collections [ATCC] 25922, Pseudomonas aeruginosa ATCC 27853, Staphylococcus aureus ATCC 29213, or Bacteroides fragilis ATCC 25285) in amounts ranging from 2,000 to 4,000 colony forming units/ml. The blood was processed via a cell salvage machine. The washed blood was then filtered using a leukocyte reduction filter. The results for blood taken during each step of processing were compared using a repeated-measures design. Fifteen units of blood were contaminated with each of the stock bacteria. From the prewash sample to the postfiltration sample, 99.0%, 99.6%, 100%, and 97.6% of E. coli, S. aureus, P. aeruginosa, and B. fragilis were removed, respectively. Significant but not complete removal of contaminating bacteria was seen. An increased level of patient safety may be added to cell salvage by including a leukocyte depletion filter when salvaging blood that might be grossly contaminated with bacteria.

  15. Sensitive identification of mycobacterial species using PCR-RFLP on bronchial washings.

    Science.gov (United States)

    Hidaka, E; Honda, T; Ueno, I; Yamasaki, Y; Kubo, K; Katsuyama, T

    2000-03-01

    In 98 patients (24 with active pulmonary tuberculosis [TB] lesions, 28 with cured TB lesions, and 46 with nontuberculous opacities [control group] in chest CT scans), we examined whether washing the bronchus after brushing the lesion, then applying polymerase chain reaction-restriction fragment length polymorphism (PCR-RFLP) to the bronchial washings might be useful for diagnosing TB and nontuberculous mycobacteriosis (NTMosis). After biopsy and brushing with a bronchoscope, the bronchus connecting to the lesion was washed with 20 ml saline. The saline used for washing the brushes (5 ml; brushing sample), and 3 to 10 ml saline aspirated through the forceps channel (washing sample) were examined by PCR-RFLP, which proved able to identify Mycobacterium tuberculosis and seven species of nontuberculous mycobacteria (NTM). The values obtained for the sensitivity of the PCR-RFLP with respect to the brushing sample, the washing sample, and both samples mixed together were 70, 76, and 91%, respectively, when only patients who were culture-positive or radiologically improved after antituberculous therapy were considered as showing true infection. A mixture of brushing and washing samples provides useful material for PCR and culture, and the PCR-RFLP used here is a good method for the simultaneous identification of several species of mycobacterium (including M. tuberculosis).

  16. Understanding road surface pollutant wash-off and underlying physical processes using simulated rainfall.

    Science.gov (United States)

    Egodawatta, Prasanna; Goonetilleke, Ashantha

    2008-01-01

    Pollutant wash-off is one of the key pollutant processes that detailed knowledge is required in order to develop successful treatment design strategies for urban stormwater. Unfortunately, current knowledge relating to pollutant wash-off is limited. This paper presents the outcomes of a detailed investigation into pollutant wash-off on residential road surfaces. The investigations consisted of research methodologies formulated to overcome the physical constraints due to the heterogeneity of urban paved surfaces and the dependency on naturally occurring rainfall. This entailed the use of small road surface plots and artificially simulated rainfall. Road surfaces were selected due to its critical importance as an urban stormwater pollutant source. The study results showed that the influence of initially available pollutants on the wash-off process was limited. Furthermore, pollutant wash-off from road surfaces can be replicated using an exponential equation. However, the typical version of the exponential wash-off equation needs to be modified by introducing a non dimensional factor referred to as 'capacity factor' CF. Three rainfall intensity ranges were identified where the variation of CF can be defined. Furthermore, it was found that particulate density rather than size is the critical parameter that influences the process of pollutant wash-off. (c) IWA Publishing 2008.

  17. A review of radionuclides in tide-washed pastures on the Irish Sea coast in England and Wales and their transfer to food products

    International Nuclear Information System (INIS)

    Howard, B.J.

    1996-01-01

    Close to the Sellafield Reprocessing Plant activity concentrations of many radionuclides including the long-lived 137 Cs and actinides on tide-washed pastures bordering the Irish Sea are high compared with other terrestrial eco-systems in the United Kingdom. Despite the comparatively high deposition of radionuclides, contamination of agricultural products from tide-washed pastures is lower than would be predicted from studies in terrestrial eco-systems. This is because the main source of contamination in tide-washed pasture, radionuclides associated with sedimentary particles, has low availability for uptake by plant roots and in the gut of ruminants. Generalised Derived Limits (GDLs), published by the National Radiological Protection Board (NRPB) are estimates of environmental radioactivity concentrations which would potentially be radiologically significant. These provide a benchmark against which environmental measurements can be assessed. In the past, several comparisons of radioactivity concentrations in tide-washed pastures with GDLs have been made, but only some of these comparisons are valid since current approaches used to assess doses are not always strictly appropriate to these ecosystems. Directly applicable GDLs are needed, and are currently being developed by the NRPB. (Author)

  18. Sucrose-supplemented distillery spent wash as a medium for production of ethanol at 45 C by free and alginate-immobilized preparations of Kluyveromyces marxianus IMB3

    Energy Technology Data Exchange (ETDEWEB)

    Ferguson, P.; Mulholland, H.; Barron, N.; Brady, D.; McHale, A.P. [Biotechnology Research Group, School of Applied Biological and Chemical Sciences, University of Ulster (United Kingdom)

    1998-04-01

    Ethanol production by the thermotolerant, ethanol-producing yeast strain Kluyveromyces marxianus IMB3, was compared during growth on sucrose-supplemented laboratory-based media and distillery spent wash from the Old Bushmill`s Distillery Co., Ltd., Co. Antrim, Northern Ireland. Fermentations were carried out using preparations of the free and alginate-immobilized microorganism as inocula in media supplemented with 2 and 10% (w/v) sucrose. Maximum ethanol concentrations accounted for 75-99% of the maximum theoretical yield and in all cases maximum concentrations obtained using the spent wash were similar if not slightly higher than those obtained on the sucrose-supplemented yeast growth media. In addition, the highest concentrations of ethanol were produced by the alginate-immobilized biocatalyst on both types of media. Analysis of exhausted media in the spent wash-based systems demonstrated significant decreases in the total organic carbon content following fermentation. These results confirm our earlier suggestion that ethanol production based on this microorganism in a recycle system may provide a more cost-effective means of disposing of whiskey distillery spent wash. (orig.) With 1 tab., 8 refs.

  19. Evaluation of microplastic release caused by textile washing processes of synthetic fabrics.

    Science.gov (United States)

    De Falco, Francesca; Gullo, Maria Pia; Gentile, Gennaro; Di Pace, Emilia; Cocca, Mariacristina; Gelabert, Laura; Brouta-Agnésa, Marolda; Rovira, Angels; Escudero, Rosa; Villalba, Raquel; Mossotti, Raffaella; Montarsolo, Alessio; Gavignano, Sara; Tonin, Claudio; Avella, Maurizio

    2018-05-01

    A new and more alarming source of marine contamination has been recently identified in micro and nanosized plastic fragments. Microplastics are difficult to see with the naked eye and to biodegrade in marine environment, representing a problem since they can be ingested by plankton or other marine organisms, potentially entering the food web. An important source of microplastics appears to be through sewage contaminated by synthetic fibres from washing clothes. Since this phenomenon still lacks of a comprehensive analysis, the objective of this contribution was to investigate the role of washing processes of synthetic textiles on microplastic release. In particular, an analytical protocol was set up, based on the filtration of the washing water of synthetic fabrics and on the analysis of the filters by scanning electron microscopy. The quantification of the microfibre shedding from three different synthetic fabric types, woven polyester, knitted polyester, and woven polypropylene, during washing trials simulating domestic conditions, was achieved and statistically analysed. The highest release of microplastics was recorded for the wash of woven polyester and this phenomenon was correlated to the fabric characteristics. Moreover, the extent of microfibre release from woven polyester fabrics due to different detergents, washing parameters and industrial washes was evaluated. The number of microfibres released from a typical 5 kg wash load of polyester fabrics was estimated to be over 6,000,000 depending on the type of detergent used. The usage of a softener during washes reduces the number of microfibres released of more than 35%. The amount and size of the released microfibres confirm that they could not be totally retained by wastewater treatments plants, and potentially affect the aquatic environment. Copyright © 2017 Elsevier Ltd. All rights reserved.

  20. [Preparation and antimicrobial effect of aromatic, natural and bacteriostatic foot wash with skin care].

    Science.gov (United States)

    Gao, Su-Hua; Zhao, Guo-Xiang; Yang, Xiao-Dong; Xu, Ling-Ling

    2013-06-01

    To prepare the aromatic, natural and bacteriostatic foot wash with skin care and research the inhibition effect on the different bacteria and pathogenic fungus which cause dermatophytosis. It was prepared by using Sophoraflavescens and Dictamnus dasycarpus as materials with the addition of Aloe extract, essential oil, surfactant, etc. The antifungal and antibacterial activity was researched by the levitation liquid quantitative method. The foot wash smelled faintly scent. The use of this product can produce a rich foam. The inhibitory rate were all more than 90%. The preparation process of the foot wash was simple. It has obviously bacteriostatic and fungistatic effect.

  1. Residues of maneb in potatoes and lettuce and their persistence during cooking, washing and uv exposition

    International Nuclear Information System (INIS)

    Bennaceur, M.; Sennaoui, Z.; Zennouche, B.; Hylin, J.W.

    1992-01-01

    Lettuce plants were treated each with 0,186 mg of 14C maneb and 1,86 mg unlabelled maneb. The plants were analyzed 30 days later and subjected to washing. Washing eliminates 17,46% of total 14C maneb applied. No Etu was observed in water.Washing and baking cause a significant decrease of EBDC in potatoes samples and the UV exposition involves a decrease of the fungicide and a formation of Etu. On the other hand 54 % and 38% of lettuce and potatoe samples analyzed by CS2 method exceed the authorized norms

  2. Superstorm Sandy marine debris wash-ups on Long Island - What happened to them?

    Science.gov (United States)

    Swanson, R Lawrence; Lwiza, Kamazima; Willig, Kaitlin; Morris, Kaitlin

    2016-07-15

    Superstorm Sandy generated huge quantities of debris in the Long Island, NY coastal zone. However, little appears to have been washed offshore to eventually be returned to Long Island's beaches as marine debris wash-ups. Information for our analysis includes debris collection statistics, very high resolution satellite images, along with wind and sea level data. Rigorous debris collection efforts along with meteorological conditions following the storm appear to have reduced the likelihood of debris wash-ups. Copyright © 2016 Elsevier Ltd. All rights reserved.

  3. Are the Effects of University Teacher Education "Washed Out" by School Experience?

    Science.gov (United States)

    Zeichner, Kenneth M.; Tabachnick, B. Robert

    1981-01-01

    Numerous studies on the education of teachers indicate that, as students advance educationally, their attitudes and beliefs tend to become increasingly liberal and progressive. However, the impact of the college education is "washed out" by the teaching experience. (JN)

  4. Washing of gel particles in wet chemical manufacture of reactor fuel particles

    International Nuclear Information System (INIS)

    Ringel, H.

    1980-07-01

    In the manufacture of HTR fuel particles and particles of fertile material by wet chemical methods, the ammonium nitrate formed during the precipitation reaction must be washed out of the gel particles. This washing process has been investigated theoretically and experimentally. A counter-current washer has been developed which in particular takes account of the aspects of refabrication - such as compact construction and minimum waste. A counter-current washing column of 17 mm internal diameter and 640 mm length gives to gel particle throughput of 0.65 1/h. The volume ratio of wash water to gel particles is 5, and the residual nitrate concentration in the particles is 7 x 10 -3 mols of NO - 3 /1. (orig.) [de

  5. Title V Operating Permit: QEP Field Services Company - Coyote Wash Compressor Station

    Science.gov (United States)

    Response to public comments and the Title V Operating Permit for the QEP Field Services Company, Coyote Wash Compressor Station, located on the Uintah and Ouray Indian Reservation in Uintah County, Utah.

  6. Internalization of Listeria monocytogenes in cantaloupes during dump tank washing and hydrocooling

    Science.gov (United States)

    Recent listeriosis outbreaks and recalls associated with cantaloupes urge for studies to understand the mechanisms of cantaloupe contamination by Listeria monocytogenes. Postharvest practices such as washing and hydrocooling were suggested to facilitate the contamination of fresh fruits by human pat...

  7. Washing away your (good or bad) luck: physical cleansing affects risk-taking behavior.

    Science.gov (United States)

    Xu, Alison Jing; Zwick, Rami; Schwarz, Norbert

    2012-02-01

    Many superstitious practices entail the belief that good or bad luck can be "washed away." Consistent with this belief, participants who recalled (Experiment 1) or experienced (Experiment 2) an episode of bad luck were more willing to take risk after having as opposed to not having washed their hands, whereas participants who recalled or experienced an episode of good luck were less willing to take risk after having as opposed to not having washed their hands. Thus, the psychological effects of physical cleansings extend beyond the domain of moral judgment and are independent of people's motivation: incidental washing not only removes undesirable traces of the past (such as bad luck) but also desirable ones (such as good luck), which people would rather preserve.

  8. Hair dyeing, hair washing and hair cortisol concentrations among women from the healthy start study

    DEFF Research Database (Denmark)

    Kristensen, Sheila K.; Larsen, Sofus C.; Olsen, Nanna J.

    2017-01-01

    Background: Hair cortisol concentration (HCC) has been suggested as a promising marker for chronic stress. However, studies investigating the influence of hair dyeing and hair washing frequency on HCC have shown inconsistent results. Objective: To examine associations between HCC and hair dyeing...... status or weekly hair washing frequency among women. Methods: This cross-sectional study was based on data from 266 mothers participating in the Healthy Start intervention study. HCC was measured in the proximal end of the hair (1–2 cm closest to the scalp) while hair dyeing status, frequency of hair...... washing and covariates were reported by the women. Linear regression analyses were applied to assess the associations between HCC and hair dyeing or weekly frequency of hair washing. Results: No statistically significant difference (p = 0.91) in HCC was found between women who dyed hair (adjusted mean...

  9. Ultrasonic and mechanical soil washing processes for the remediation of heavy-metal-contaminated soil

    Science.gov (United States)

    Kim, Seulgi; Lee, Wontae; Son, Younggyu

    2016-07-01

    Ultrasonic/mechanical soil washing process was investigated and compared with ultrasonic process and mechanical process using a relatively large lab-scale sonoreactor. It was found that higher removal efficiencies were observed in the combined processes for 0.1 and 0.3 M HCl washing liquids. It was due to the combination effects of macroscale removal for the overall range of slurry by mechanical mixing and microscale removal for the limited zone of slurry by cavitational actions.

  10. Study of electroflotation method for treatment of wastewater from washing soil contaminated by heavy metals

    OpenAIRE

    de Oliveira da Mota, Izabel; de Castro, José Adilson; de Góes Casqueira, Rui; de Oliveira Junior, Angelo Gomes

    2015-01-01

    Electroflotation method (EFM) for treatment of synthetic solutions simulating wastewater from washing soil contaminated by drilling fluids from oil wells was investigated in this paper. Experiments were carried out to examine the effects of the operating conditions on the removal of lead, barium and zinc from solutions containing 15 mg dm−3 for each metal representing a typical concentration of wastewater generated in the washing soil in this treatment. The experimental results showed that it...

  11. Humic substances as a washing agent for Cd-contaminated soils.

    Science.gov (United States)

    Meng, Fande; Yuan, Guodong; Wei, Jing; Bi, Dongxue; Ok, Yong Sik; Wang, Hailong

    2017-08-01

    Cost-effective and eco-friendly washing agents are in demand for Cd contaminated soils. Here, we used leonardite-derived humic substances to wash different types of Cd-contaminated soils, namely, a silty loam (Soil 1), a silty clay loam (Soil 2), and a sandy loam (Soil 3). Washing conditions were investigated for their effects on Cd removal efficiency. Cadmium removal was enhanced by a high humic substance concentration, long washing time, near neutral pH, and large solution/soil ratio. Based on the tradeoff between efficiency and cost, an optimum working condition was established as follows: humic substance concentration (3150 mg C/L), solution pH (6.0), washing time (2 h) and a washing solution/soil ratio (5). A single washing removed 0.55 mg Cd/kg from Soil 1 (1.33 mg Cd/kg), 2.32 mg Cd/kg from Soil 2 (6.57 mg Cd/kg), and 1.97 mg Cd/kg from Soil 3 (2.63 mg Cd/kg). Cd in effluents was effectively treated by adding a small dose of calcium hydroxide, reducing its concentration below the discharge limit of 0.1 mg/L in China. Being cost-effective and safe, humic substances have a great potential to replace common washing agents for the remediation of Cd-contaminated soils. Besides being environmentally benign, humic substances can improve soil physical, chemical, and biological properties. Copyright © 2017 Elsevier Ltd. All rights reserved.

  12. Effects of lead mineralogy on soil washing enhanced by ferric salts as extracting and oxidizing agents.

    Science.gov (United States)

    Yoo, Jong-Chan; Park, Sang-Min; Yoon, Geun-Seok; Tsang, Daniel C W; Baek, Kitae

    2017-10-01

    In this study, we evaluated the feasibility of using ferric salts including FeCl 3 and Fe(NO 3 ) 3 as extracting and oxidizing agents for a soil washing process to remediate Pb-contaminated soils. We treated various Pb minerals including PbO, PbCO 3 , Pb 3 (CO 3 ) 2 (OH) 2 , PbSO 4 , PbS, and Pb 5 (PO 4 ) 3 (OH) using ferric salts, and compared our results with those obtained using common washing agents of HCl, HNO 3 , disodium-ethylenediaminetetra-acetic acid (Na 2 -EDTA), and citric acid. The use of 50 mM Fe(NO 3 ) 3 extracted significantly more Pb (above 96% extraction) from Pb minerals except PbSO 4 (below 55% extraction) compared to the other washing agents. In contrast, washing processes using FeCl 3 and HCl were not effective for extraction from Pb minerals because of PbCl 2 precipitation. Yet, the newly formed PbCl 2 could be dissolved by subsequent wash with distilled water under acidic conditions. When applying our washing method to remediate field-contaminated soil from a shooting range that had high concentrations of Pb 3 (CO 3 ) 2 (OH) 2 and PbCO 3 , we extracted more Pb (approximately 99% extraction) from the soil using 100 mM Fe(NO 3 ) 3 than other washing agents at the same process conditions. Our results show that ferric salts can be alternative washing agents for Pb-contaminated soils in view of their extracting and oxidizing abilities. Copyright © 2017 Elsevier Ltd. All rights reserved.

  13. Water usage characteristics of car wash facilities in Ortahisar district of Trabzon province

    OpenAIRE

    Karabacak, Volkan; Topbaş, Murat; Karakullukçu, Serdar; Demirtaş, Yusuf; Çankaya, Sertaç; Çan, Gamze; Beyhun, N. Ercüment

    2018-01-01

    Introduction. Water management is ontop of the agenda for all countries Aimof the study. The aim of this study was to determine the water usage in thecar wash facilities of Ortahisar district of Trabzon province, such as thefeatures of the water used in drinking and car washing, the disposal ofwastewater and case of water interruption situation in the facilities. Material and methods. This descriptivestudy was conducted in Ortahisar district of Trabzon province. The studypopulation of the res...

  14. Soil physical characteristics after EDTA washing and amendment with inorganic and organic additives

    International Nuclear Information System (INIS)

    Zupanc, Vesna; Kastelec, Damijana; Lestan, Domen; Grcman, Helena

    2014-01-01

    Soil washing has been established as suitable remediation technology, with most research focused on metal removing efficiency and toxic effect on plants, less on the influence on soil physical characteristics, which was the focus of this study. In soil column experiment highly contaminated soil and soil washed with EDTA, mixed with additives (gypsum, hydrogel, manure, peat) were tested. White clover was used as a soil cover. Yield, metal concentration in soil and plant, aggregate fractionation and stability, saturated hydraulic conductivity and soil water retention of the soil were measured. Soil washing decreased metal concentration in soil and plants, but yield of white clover on remediated soil was significantly lower compared to the original soil. Significant differences in water retention characteristics, aggregate fractionation and stability between original and remediated soil have been determined. Gypsum, hydrogel and peat increased plant available water, manure and peat increased yield on remediated soil. -- Highlights: • Clover yield on washed soil was significantly lower than on original soil. • Organic additives increased yield on remediated soils. • Soil washing changed soil water retention and soil structure. • Hydrogen, gypsum and peat increased plant available water of remediated soil. -- The study critically examines yield, plant metal uptake and possible changes in soil physical characteristics as a consequence of soil washing procedure for metal pollution remediation

  15. Effect and Removal Mechanisms of 6 Different Washing Agents for Building Wastes Containing Chromium

    Directory of Open Access Journals (Sweden)

    Wang Xing-run

    2012-01-01

    Full Text Available With the building wastes contaminated by chromium in Haibei Chemical Plan in China as objects, we studied the contents of total Cr and Cr (VI of different sizes, analyzed the effect of 6 different washing agents, discussed the removal mechanisms of 6 different washing agents for Cr in various forms, and finally selected applicable washing agent. As per the results, particle size had little impact on the contents of total Cr and Cr (VI; after one washing with water, the removal rate of total Cr and Cr (VI was 75% and 78%, respectively, and after the second washing with 6 agents, the removal rate of citric acid was the highest, above 90% for total Cr and above 99% for hexavalent chromium; the pH of building wastes were reduced by citric acid, and under acid condition, hexavalent chromium was reduced to trivalent chromium spontaneously by organic acid, which led to better removal rate of acid soluble Cr and reducible Cr; due to the complexing action, citric acid had best removal rate for oxidizable trivalent chromium. In conclusion, citric acid is the most applicable second washing agent for building wastes.

  16. Evaluation of different water-washing treatments effects on wheat straw combustion properties.

    Science.gov (United States)

    Ma, Qiulin; Han, Lujia; Huang, Guangqun

    2017-12-01

    A series of experiments was conducted to explore the effects of various water-washing solid-liquid ratios (1:50 and 1:10) and the stirring on wheat straw (WS) combustion properties. Comparing different solid-liquid ratio groups, a 16% increment in the higher heating value was obtained for 1:50 groups and only 5% for 1:10 groups relative to the raw material. Moreover, energy was lost 4-26 times greater in 1:10 groups than 1:50 groups. While water-washing reduced the comprehensive combustibility index by 14.89%-32.09%, the index values of washed WS were all higher than 2, indicating good combustion performance. The combustion activation energy of four washed WS were 175, 172, 186, and 176kJ/mol, which were all higher than the 160kJ/mol of WS. The fouling/slagging propensity of washed WS reduced to a lower possibility compared to medium of untreated WS. Overall, the recommended condition for washing WS before combustion is 1:50 ratio without stirring. Copyright © 2017. Published by Elsevier Ltd.

  17. Nitrogen washing from C3 and C4 cover grasses residues by rain

    Directory of Open Access Journals (Sweden)

    Ciro Antonio Rosolem

    2010-12-01

    Full Text Available Crop species with the C4 photosynthetic pathway are more efficient in assimilating N than C3 plants, which results in different N amounts prone to be washed from its straw by rain water. Such differences may affect N recycling in agricultural systems where these species are grown as cover crops. In this experiment, phytomass production and N leaching from the straw of grasses with different photosynthetic pathways were studied in response to N application. Pearl millet (Pennisetum glaucum and congo grass (Brachiaria ruziziensis with the C4 photosynthetic pathway, and black oat (Avena Strigosa and triticale (X Triticosecale, with the C3 photosynthetic pathway, were grown for 47 days. After determining dry matter yields and N and C contents, a 30 mm rainfall was simulated over 8 t ha-1 of dry matter of each plant residue and the leached amounts of ammonium and nitrate were determined. C4 grasses responded to higher fertilizer rates, whereas N contents in plant tissue were lower. The amount of N leached from C4 grass residues was lower, probably because the C/N ratio is higher and N is more tightly bound to organic compounds. When planning a crop rotation system it is important to take into account the difference in N release of different plant residues which may affect N nutrition of the subsequent crop.

  18. Synthetic fibers as microplastics in the marine environment: A review from textile perspective with a focus on domestic washings.

    Science.gov (United States)

    Salvador Cesa, Flavia; Turra, Alexander; Baruque-Ramos, Julia

    2017-11-15

    The ubiquity of plastic materials in the environment has been, for long, a matter of discussion. Smaller particles, named microplastics (textile materials are a subgroup of microplastics and can be originated from domestic washings, as machine filters and wastewater treatment plants (WWTPs) are not specifically designed to retain them. Once in the environment, fibers can reach concentrations up to thousands of particles per cubic meter, being available to be ingested by a broad range of species. In this scenario, this review adds and details the textile perspective to the microplastics exploring nomenclature, characteristics and factors influencing emission, but also evidencing gaps in knowledge needed to overcome this issue. Preliminarily, general information about marine litter and plastics, followed by specific aspects regarding textile fibers as microplastics, were introduced. Then fiber sources to microplastic pollution were discussed, mainly focusing on domestic washings that pass through WWTPs. Studies that reveal domestic washing as microplastic sources are scarce and there is a considerable lack of standardization in methods as well as incorporation of textile aspects in experimental design. Knowledge gaps include laundry parameters (e.g., water temperature, use of chemicals) and textile articles characteristics (e.g., yarn type, fabric structure) orchestrated by consumers' choice. The lack of information on the coverage and efficiency of sewage treatment systems to remove textile fibers also prevent a global understanding of such sources. The search of alternatives and applicable solutions should come from an integrated, synergic and global perspective, of both environmental and textile area, which still need to be fostered. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. Arsenic bioavailability in soils before and after soil washing: the use of Escherichia coli whole-cell bioreporters.

    Science.gov (United States)

    Yoon, Youngdae; Kang, Yerin; Chae, Yooeun; Kim, Sunghoon; Lee, Youngshim; Jeong, Seung-Woo; An, Youn-Joo

    2016-02-01

    We investigated the quantification of bioavailable arsenic in contaminated soils and evaluation of soil-washing processes in the aspect of bioavailability using a novel bacterial bioreporter developed in present study. The whole-cell bioreporter (WCB) was genetically engineered by fusing the promoter of nik operon from Escherichia coli and green fluorescent protein as a sensing domain and reporter domain. Among eight well-known hazardous heavy metals and metalloid, this system responded specifically to arsenic, thereby inferring association of As(III) with NikR inhibits the repression. Moreover, the response was proportional to the concentration of As(III), thereby it was capable to determine the amount of bioavailable arsenic quantitatively in contaminated soils. The bioavailable portion of arsenic was 5.9 (3.46-10.96) and 0.9 (0.27-1.74) % of total from amended and site soils, respectively, suggesting the bioavailability of arsenic in soils was related to the soil properties and duration of aging. On the other hand, only 1.37 (0.21-2.97) % of total arsenic was extracted into soil solutions and 19.88 (11.86-28.27) % of arsenic in soil solution was bioavailable. This result showed that the soluble arsenic is not all bioavailable and most of bioavailable arsenic in soils is water non-extractable. In addition, the bioavailable arsenic was increased after soil-washing while total amount was decreased, thereby suggesting the soil-washing processes release arsenic associated with soil materials to be bioavailable. Therefore, it would be valuable to have a tool to assess bioavailability and the bioavailability should be taken into consideration for soil remediation plans.

  20. Comparative characterization of the quaternary deposits of Northwest Peninsular Malaysia by wash boring and CPTU site investigation methods

    Science.gov (United States)

    Selamat, Mohamad R.; Rosli, Ros N.; Ramli, Muhd H.; Azmi, Mastura; Kumaravelu, Prakash; Govindasamy, Darvintharen

    2017-10-01

    A site investigation by wash boring method was carried out in the compound of the Engineering Campus, Universiti Sains Malaysia, in Northwest Peninsular Malaysia. The subsurface soils of the region are known to be comprised of quaternary deposits including the prominent marine clays of the Gula formation. The conventional Standard Penetration Test, or SPT, was carried out for every 1.5m depth. The 18 disturbed samples collected were tested for grain size distribution, Atterberg limits, and specific gravity; and categorized according to the unified soil classification system. The results indicate low SPT numbers, or SPTN, i.e. SPTN8 for depths deeper than 12m. Samples from shallower than 12m were mostly classified as low plasticity clay, or CL, which represents the soft marine clay while the underlying materials were mostly sands, namely poorly graded sand, or SP, silty sand, or SM, clayey sand, or SC, and well graded sand, or SW. Another site investigation by the CPTU method was also carried out 5m from the wash boring position, penetrating the entire soft clay stratum, thus giving another marine clay characterization in addition to the one given by the first method. The CPTU results generally gave SPTN≤2 for depths lesser than 8m, 2≤;SPTN≤4 for depths between 8 and 12m, and SPTN=23 at 12.5m, where the CPTU test terminated. The CPTU method classified the soft materials as sensitive fine grains, clays, and clayey silts to silty clays. Thus the CPTU results did not agree very well with the conventional wash boring SPT results in terms of the SPTN obtained. Nevertheless both methods equally identified the prominent presence of the soft marine clay stratum in the top 12.5m and the underlying strong sandy bed with higher bearing capacity values.

  1. Emulsion type dry cleaning system

    International Nuclear Information System (INIS)

    Kohanawa, Osamu; Matsumoto, Hiroyo.

    1988-01-01

    Protective clothing against radioactive contamination used in the radiation controlled areas of nuclear plants has been washed by the same wet washing as used for underwear washing, but recently dry cleaning is getting used in place of wet washing, which generates a large quantity of laundry drain. However, it was required to use wet washing once every five to ten dry cleanings for washing protective clothing, because conventional dry cleaning is less effective in removing water-soluble soils. Therefore, in order to eliminate wet washing, and to decrease the quantity of laundry drains, the emulsion type dry cleaning system capable of removing both oil-soluble and water-soluble soils at a time has been developed. The results of developmental experiments and actual application are presented in this paper. (author)

  2. Testing biological effects of hand-washing grey water for reuse in irrigation on an urban farm: a case study.

    Science.gov (United States)

    Khan, Mohammad Zain; Sim, Yei Lin; Lin, Yang Jian; Lai, Ka Man

    2013-01-01

    The feasibility of reusing hand-washing grey water contaminated with antibacterial hand-washing liquid for irrigation purposes in an urban farm is explored in this case study. Experiments are carried out to investigate if the quality of this grey water allows for its reuse in agriculture as per the guidelines established by the World Health Organization (WHO). However, there is no guideline to test the biological effect of grey water prior to agricultural use. It is plausible that the antibacterial property of the grey water can harm the soil microbial system and plants when applied to land, even if all other water quality parameters satisfy the WHO limit. We use algae (Chlorella vulgaris) and indigenous soil bacteria as initial plant and soil bacteria indicators, respectively, to test the potential inhibition of the water on plants and soil bacteria. Results show that the chemical oxygen demand (COD) of the grey water is 10% higher than the WHO permissible level, while all other water quality parameters are within the limits after four days of our experimental period. An inhibitory effect is observed in all of the biological tests. However, the inhibitory effect on algae and soil bacteria is not observed after the four-day period. The case study demonstrates a new approach for testing the biological effect of grey water, which can be used in conjunction with the WHO guideline, and provides data for this urban farm to set up a future water treatment system for grey-water reuse in irrigation.

  3. Washing away your sins will set your mind free: physical cleansing modulates the effect of threatened morality on executive control.

    Science.gov (United States)

    Kalanthroff, Eyal; Aslan, Chen; Dar, Reuven

    2017-01-01

    The effect of threatened morality on negative emotions and on altruistic behaviour has been shown to diminish following physical cleansing (hand-washing). We hypothesised that threatened morality will broadly impair the executive control system, and that physical cleansing will moderate this detrimental effect. Thirty-seven participants were asked to write about an immoral deed they had committed, whereupon half of them were allowed to wipe their hands. Three executive control tasks-Stroop, stop-signal, and object interference-were then administered to all participants. Participants who had not wiped their hands, but not those who did, demonstrated impaired performance, compared to hand-washing controls, in all three tasks. We conclude that threatened morality has a detrimental effect on executive control, specifically on conflict monitoring and response inhibition, and that physical cleansing "frees" this system, counteracting the detrimental effects of morality threats. We discuss possible implications for obsessive-compulsive disorder, which is characterised by deficient executive control and in which both threatened morality and physical cleansing are central concerns.

  4. Effects of process parameters on ozone washing for denim using 3/sup 3/ factorial design

    International Nuclear Information System (INIS)

    Asim, F.; Mahmood, M.

    2017-01-01

    Denim garment is getting popular day by day. It is highly demandable because of its versatility, comfort and durability. Different techniques of denim washing increase this demand drastically. Denim washing is the process to enhance the appearance of a garment. This enhanced appearance may be the aged look, faded look, greyer cast, or any other shade setting or resin application. The two most advanced washing techniques are; ozone wash and laser wash. The effects of ozone on environment as well as on the garment are significant and cannot be neglected because number of benefits achieved such as time saving, less energy consumption, chemical, labour cost reduction, less discharge of water and chemicals. Therefore, effects of process parameters on ozone washing for denim fabric have been investigated in this research work using three level factorial design. 33 factorial design has been designed and conducted to investigate the effect of gas concentration, time and speed on the response variables namely; Shrinkage, Tensile and Tear strength of ozone washing. The influence of individual factors and their interactions has been critically examined using software Design Expert 8.0. Prior to the analysis of variance model accuracy has been examined through various residuals plots. The study of residuals plots shown that the residuals are normally distributed and significant evidence of possible outliers was not found. So the model can be used to predicted results with 95% confidence interval. The results from the experiment suggest that two out of three factors were significant, which are speed and time that influences mainly on the tear strength of the denim garment. (author)

  5. Development of high-performance supercapacitor electrode derived from sugar industry spent wash waste.

    Science.gov (United States)

    Mahto, Ashesh; Gupta, Rajeev; Ghara, Krishna Kanta; Srivastava, Divesh N; Maiti, Pratyush; D, Kalpana; Rivera, Paul-Zavala; Meena, R; Nataraj, S K

    2017-10-15

    This study aims at developing supercapacitor materials from sugar and distillery industry wastes, thereby mediating waste disposal problem through reuse. In a two-step process, biomethanated spent wash (BMSW) was acid treated to produce solid waste sludge and waste water with significantly reduced total organic carbon (TOC) and biological oxygen demand (BOD) content. Further, waste sludge was directly calcined in presence of activating agent ZnCl 2 in inert atmosphere resulting in high surface area (730-900m 2 g -1 ) carbon of unique hexagonal morphology. Present technique resulted in achieving two-faceted target of liquid-solid waste remediation and production of high-performance carbon material. The resulted high surface area carbon was tested in both three and two electrode systems. Electrochemical tests viz. cyclic voltammetry, galvanostatic charge-discharge and impedance measurement were carried out in aqueous KOH electrolyte yielding specific capacitance as high as 120Fg -1 , whereas all solid supercapacitor devised using PVA/H 3 PO 4 polyelectrolyte showed stable capacitance of 105Fg -1 at 0.2Ag -1 . The presence of transition metal particles and hetero-atoms on carbon surface were confirmed by XPS, EDX and TEM analysis which enhanced the conductivity and imparted pseudocapacitance to some extent into the working electrode. The present study successfully demonstrated production of high-performance electrode material from dirtiest wastewater making process green, sustainable and economically viable. Copyright © 2017. Published by Elsevier B.V.

  6. Preventing microbial growth on pall-rings when upgrading biogas using absorption with water wash

    Energy Technology Data Exchange (ETDEWEB)

    Haakansson, Anna

    2006-07-15

    For produced biogas to be usable as vehicle fuel it has to be upgraded to a higher energy content. This is accomplished by elevation of the methane concentration through removal of carbon dioxide. Absorption with water wash is the most common upgrading method used in Sweden today. The upgrading technique is based on the fact that carbon dioxide is more soluble in water than methane. Upgrading plants that utilises this method have problems with microbial growth in the system. This growth eventually leads to a stop in operation due to the gradually drop in upgrading capacity. The aim of this thesis were to evaluate the possibility to through some kind of water treatment maintain an acceptable level of growth or altogether prevent it in order to maintain an acceptable process capacity and thereby avoid the need to clean. Through collection of literature the implementation possibilities were evaluated with regard to efficiency, economic sustainability and if there would be a release of any harmful substances. In order to prevent the microbial growth in the columns the treatment should either focus on removing microorganisms or limit the accessible nutrients. For the single pass system it is concluded that the treatment should reduce the biofilm formation and be employed in an intermittent way. Among the evaluated treatments focusing on the reduction of microorganisms the addition of peracetic acid seems to be the most promising one. For the regenerating system the treatment method could focus on either one. As for the single pass system peracetic acid could be added to reduce the amount of microorganism. To reduce the amount of organic matter an advanced oxidation process could be deployed with the advantage that it also could remove the microorganisms.

  7. Impact of electrochemical treatment of soil washing solution on PAH degradation efficiency and soil respirometry

    International Nuclear Information System (INIS)

    Mousset, Emmanuel; Huguenot, David; Hullebusch, Eric D. van; Oturan, Nihal; Guibaud, Gilles; Esposito, Giovanni; Oturan, Mehmet A.

    2016-01-01

    The remediation of a genuinely PAH-contaminated soil was performed, for the first time, through a new and complete investigation, including PAH extraction followed by advanced oxidation treatment of the washing solution and its recirculation, and an analysis of the impact of the PAH extraction on soil respirometry. The study has been performed on the remediation of genuine PAH-contaminated soil, in the following three steps: (i) PAH extraction with soil washing (SW) techniques, (ii) PAH degradation with an electro-Fenton (EF) process, and (iii) recirculation of the partially oxidized effluent for another SW cycle. The following criteria were monitored during the successive washing cycles: PAH extraction efficiency, PAH oxidation rates and yields, extracting agent recovery, soil microbial activity, and pH of soil. Two representative extracting agents were compared: hydroxypropyl-beta-cyclodextrin (HPCD) and a non-ionic surfactant, Tween"® 80. Six PAH with different numbers of rings were monitored: acenaphthene (ACE), phenanthrene (PHE), fluoranthene (FLA), pyrene (PYR), benzo(a)pyrene (BaP), and benzo(g,h,i)perylene (BghiP). Tween"® 80 showed much better PAH extraction efficiency (after several SW cycles) than HPCD, regardless of the number of washing cycles. Based on successive SW experiments, a new mathematical relation taking into account the soil/water partition coefficient (Kd*) was established, and could predict the amount of each PAH extracted by the surfactant with a good correlation with experimental results (R"2 > 0.975). More HPCD was recovered (89%) than Tween"® 80 (79%), while the monitored pollutants were completely degraded (>99%) after 4 h and 8 h, respectively. Even after being washed with partially oxidized solutions, the Tween"® 80 solutions extracted significantly more PAH than HPCD and promoted better soil microbial activity, with higher oxygen consumption rates. Moreover, neither the oxidation by-products nor the acidic media (p

  8. Effects of egg shell quality and washing on Salmonella Infantis penetration.

    Science.gov (United States)

    Samiullah; Chousalkar, K K; Roberts, J R; Sexton, M; May, D; Kiermeier, A

    2013-07-15

    The vast majority of eggs in Australia are washed prior to packing to remove dirt and fecal material and to reduce the microbial contamination of the egg shell. The egg contents can be an ideal growth medium for microorganisms which can result in human illness if eggs are stored improperly and eaten raw or undercooked, and it is estimated that egg-related salmonellosis is costing Australia $44 million per year. Egg shell characteristics such as shell thickness, amount of cuticle present, and thickness of individual egg shell layers can affect the ease with which bacteria can penetrate the egg shell and washing could partially or completely remove the cuticle layer. The current study was conducted to investigate the effects of egg washing on cuticle cover and effects of egg shell quality and cuticle cover on Salmonella Infantis penetration of the egg shell. A higher incidence of unfavorable ultrastructural variables of the mammillary layer such as late fusion, type B bodies, type A bodies, poor cap quality, alignment, depression, erosion and cubics were recorded in Salmonella penetrated areas of egg shells. The influence of egg washing on the ability of Salmonella Infantis on the egg shell surface to enter the egg internal contents was also investigated using culture-based agar egg penetration and real-time qPCR based experiments. The results from the current study indicate that washing affected cuticle cover. There were no significant differences in Salmonella Infantis penetration of washed or unwashed eggs. Egg shell translucency may have effects on Salmonella Infantis penetration of the egg shell. The qPCR assay was more sensitive for detection of Salmonella Infantis from egg shell wash and internal contents than traditional microbiological methods. The agar egg and whole egg inoculation experiments indicated that Salmonella Infantis penetrated the egg shells. Egg washing not only can be highly effective at removing Salmonella Infantis from the egg shell surface

  9. Combined soil washing and CDEO for the removal of atrazine from soils

    Energy Technology Data Exchange (ETDEWEB)

    Vieira dos Santos, Elisama [Institute of Chemistry, Federal University of Rio Grande do Norte, Lagoa Nova CEP 59078-970, Natal, RN (Brazil); Sáez, Cristina [Department of Chemical Engineering, Universidad de Castilla – La Mancha, Enrique Costa Building, Campus Universitario s/n, 13071 Ciudad Real (Spain); Martínez-Huitle, Carlos Alberto [Institute of Chemistry, Federal University of Rio Grande do Norte, Lagoa Nova CEP 59078-970, Natal, RN (Brazil); Cañizares, Pablo; Rodrigo, Manuel Andres [Department of Chemical Engineering, Universidad de Castilla – La Mancha, Enrique Costa Building, Campus Universitario s/n, 13071 Ciudad Real (Spain)

    2015-12-30

    Highlights: • Sequential soil washing-waste electrolysis is an efficient treatment for removing atrazine. • Ratio surfactant/soil influences on the size of micelles and organic load. • Electrolysis with diamond anodes oxidizes pollutants from soils washing wastes. • Electrolysis of soil washing fluids promotes the reduction in size of micelles. • Sulphate ions release from the oxidation of SDS participates in the oxidation process. - Abstract: In this work, it is studied the removal of atrazine from spiked soils by soil washing using surfactant fluids, followed by the treatment of the resulting washing waste by electrolysis with boron doped diamond (BDD) anode. Results confirm that combination of both technologies is efficient for the removal and total mineralization of atrazine. Ratio surfactant/soil is a key parameter for the removal of atrazine from soil and influences significantly in the characteristic of the wastewater produced, affecting not only to the total organic load but also to the mean size of micelles. The higher the ratio surfactant soil, the lower is the size of the particles. Electrolyses of this type of waste attain the complete mineralization. TOC and COD are removed from the start of the treatment but the key of the treatment is the reduction in size of the micelles, which lead to a higher negative charge in the surface and to the faster depletion of the surfactant as compared with the pesticide.

  10. Viscoelastic Properties of Extracellular Polymeric Substances Can Strongly Affect Their Washing Efficiency from Reverse Osmosis Membranes.

    Science.gov (United States)

    Ferrando Chavez, Diana Lila; Nejidat, Ali; Herzberg, Moshe

    2016-09-06

    The role of the viscoelastic properties of biofouling layers in their removal from the membrane was studied. Model fouling layers of extracellular polymeric substances (EPS) originated from microbial biofilms of Pseudomonas aeruginosa PAO1 differentially expressing the Psl polysaccharide were used for controlled washing experiments of fouled RO membranes. In parallel, adsorption experiments and viscoelastic modeling of the EPS layers were conducted in a quartz crystal microbalance with dissipation (QCM-D). During the washing stage, as shear rate was elevated, significant differences in permeate flux recovery between the three different EPS layers were observed. According to the amount of organic carbon remained on the membrane after washing, the magnitude of Psl production provides elevated resistance of the EPS layer to shear stress. The highest flux recovery during the washing stage was observed for the EPS with no Psl. Psl was shown to elevate the layer's shear modulus and shear viscosity but had no effect on the EPS adhesion to the polyamide surface. We conclude that EPS retain on the membrane as a result of the layer viscoelastic properties. These results highlight an important relation between washing efficiency of fouling layers from membranes and their viscoelastic properties, in addition to their adhesion properties.

  11. The Development of Treatment Process Technology for Uranium Soil washing Leachate

    Energy Technology Data Exchange (ETDEWEB)

    Shon, Dong Bin; Kim, Gye Nam; Park, Hye Min; Kim, Ki Hong; Lee, Ki Won; Moon, Jeik won [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2011-05-15

    Electrokinetic treatment technology is a good method for removing radioactive substances such as U, Co, Cs: but it has a weakness. It takes a long time to get high removal efficiency. The Soil washing method compensates for this weak point with its short reaction time and with this method it is possible to remove a lot of uranium-contaminated soil. But a great deal of leachate is generated. That is, about more amounts of leachate are generated for the decontamination of the same volume of radioactive soil using the electrokinetic equipment. Therefore, the development of a treatment process for The Soil washing leachate is important so that there is a reduction of leachate waste volume and a choice of process. Previously, studies for liquid radioactive waste were in process at various nuclear facilities. Nuclear fuel plant survey appropriate cohesion quantity of liquid waste of radioactive. Nuclear power plants manage liquid radioactive waste with centrifugation equipment. In this study, the treatment technology for uranium Soil washing leachate generated on Soil washing decontamination for the soil contaminated with uranium was developed. A treatment process suitable to the contamination characteristics of Soil washing leachate was proposed

  12. Removal of Pb, Zn, and Cd from contaminated soil by new washing agent from plant material.

    Science.gov (United States)

    Cao, Yaru; Zhang, Shirong; Wang, Guiyin; Huang, Qinling; Li, Ting; Xu, Xiaoxun

    2017-03-01

    Soil washing is an effective approach to remove soil heavy metals, and the washing agent is generally regarded as one of the primary factors in the process, but there is still a lack of efficient and eco-friendly agents for this technique. Here, we showed that four plant washing agents-from water extracts of Coriaria nepalensis (CN), Clematis brevicaudata (CB), Pistacia weinmannifolia (PW), and Ricinus communis (RC)-could be feasible agents for the removal of soil lead (Pb), zinc (Zn), and cadmium (Cd). The metal removal efficiencies of the agents increased with their concentrations from 20 to 80 g L -1 , decreased with the increasing solution pH, and presented different trends with the reaction time increasing. CN among the four agents had the highest removal efficiencies of soil Pb (62.02%) and Zn (29.18%) but owned the relatively low Cd removal efficiencies (21.59%). The Fourier transform infrared spectroscopy showed that the abilities of plant washing agents for the removal of soil heavy metals may result from bioactive substances with specific functional groups such as -COOH, -NH 2 , and -OH. Our study provided CN as the best washing agents for the remediation of contaminated soil by heavy metals.

  13. Effect of Disinfectants on Preventing the Cross-Contamination of Pathogens in Fresh Produce Washing Water

    Science.gov (United States)

    Banach, Jennifer L.; Sampers, Imca; Van Haute, Sam; van der Fels-Klerx, H.J. (Ine)

    2015-01-01

    The potential cross-contamination of pathogens between clean and contaminated produce in the washing tank is highly dependent on the water quality. Process wash water disinfectants are applied to maintain the water quality during processing. The review examines the efficacy of process wash water disinfectants during produce processing with the aim to prevent cross-contamination of pathogens. Process wash water disinfection requires short contact times so microorganisms are rapidly inactivated. Free chlorine, chlorine dioxide, ozone, and peracetic acid were considered suitable disinfectants. A disinfectant’s reactivity with the organic matter will determine the disinfectant residual, which is of paramount importance for microbial inactivation and should be monitored in situ. Furthermore, the chemical and worker safety, and the legislative framework will determine the suitability of a disinfection technique. Current research often focuses on produce decontamination and to a lesser extent on preventing cross-contamination. Further research on a sanitizer’s efficacy in the washing water is recommended at the laboratory scale, in particular with experimental designs reflecting industrial conditions. Validation on the industrial scale is warranted to better understand the overall effects of a sanitizer. PMID:26213953

  14. Study Effect of Salt Washing Process on Content and Iodium Stability of Salt

    Directory of Open Access Journals (Sweden)

    Nelson Saksono

    2010-10-01

    Full Text Available Effect of Salt Washing Process on Content and Iodium Stability of Salt. Salt washing process should increase the saltquality. It should clean the salt from sludge or clay and also reduce the impurity compound such as Mg, Ca and the reductor content. The objective of these reseach is to assess the effect of washing process on the content og hygroscopic impurities compound (Ca and Mg, and reductor content of salt. The research also investigate the water absorbing, pH, KIO3 content as function of time to obtain effect of washing process on KIO3 stability in salt. The experiment result shows that the lowest content of Mg and reductor compound 0.016 % wt and 2.65 ppm respectively which is reached at the fi ne salt washing process using 27 % wt brine. The analysis of water content indicates an increase the Ca and Mg content, causing an water absorbtion in salt , However the effect on pH the is not clear.

  15. Gravity and magnetic data of Fortymile Wash, Nevada Test Site, Nevada

    International Nuclear Information System (INIS)

    Ponce, D.A.; Kohrn, S.B.; Waddell, S.

    1992-01-01

    Gravity and ground magnetic data collected along six traverses across Fortymile Wash, in the southwest quadrant of the Nevada Test Site suggest that there are no significant vertical offsets below Fortymile Wash. The largest gravity and magnetic anomaly, in the vicinity of Fortymile Wash, is produced by the Paintbrush fault, on the west flank of Fran Ridge. Inferred vertical offset is about 250 ± 60 m (800 ± 200 ft). Geophysical data indicate that the fault is about 300 m (1,000 ft) east of its mapped, but concealed location. North of Busted Butte, near Fran Ridge, geophysical data do not preclude the existence of small vertical offsets bounding Fortymile Wash. However, gravity and magnetic profiles south of Busted Butte show little correlation to those to the north and suggest that vertical offsets, comparable in size to the Paintbrush fault, are not present. Density profiling, a technique used to determine the average density of small topographic features, suggests that the density of near-surface material in the vicinity of Fortymile Wash is 1.80 to 2.00 g/cm 3

  16. A LARCH BIOREFINERY: INFLUENCE OF WASHING AND PS CHARGE ON PRE-EXTRACTION PSAQ PULPING

    Directory of Open Access Journals (Sweden)

    Hanna S. Hörhammer

    2012-06-01

    Full Text Available This study deals with a biorefinery concept based on larch wood. Wood chips of Siberian larch (Larix sibirica Lebed. were treated with water before pulping at the optimal pre-extraction (PE condition of 150 °C and 90 minutes. Through PE, about 12.4% of the wood mass is dissolved, mainly from the arabinogalactan hemicellulose component. Fermentation of the hemicellulose-rich larch extract with Bacillus coagulans resulted in consumption of all C6 and C5 sugars and produced lactic acid in high yield. PE before pulping resulted in lower (4 to 5% pulp yield than for control kraft pulps. However, the pulp yield loss may be reduced by addition of polysulfide (PS and anthraquinone (AQ. The present study focuses on the effect of the degree of washing of the extracted chips and that of the PS charge in PSAQ pulping on the final properties of the pulp. Three different levels of washing and three different PS charges were tested. The characteristics of the extract, wash water, pulp, and black liquor samples were determined. The amount of sugars in the combined stream of collected extract and wash water obtained by mild washing was 10.2% on o.d. wood.

  17. Effect of Disinfectants on Preventing the Cross-Contamination of Pathogens in Fresh Produce Washing Water

    Directory of Open Access Journals (Sweden)

    Jennifer L. Banach

    2015-07-01

    Full Text Available The potential cross-contamination of pathogens between clean and contaminated produce in the washing tank is highly dependent on the water quality. Process wash water disinfectants are applied to maintain the water quality during processing. The review examines the efficacy of process wash water disinfectants during produce processing with the aim to prevent cross-contamination of pathogens. Process wash water disinfection requires short contact times so microorganisms are rapidly inactivated. Free chlorine, chlorine dioxide, ozone, and peracetic acid were considered suitable disinfectants. A disinfectant’s reactivity with the organic matter will determine the disinfectant residual, which is of paramount importance for microbial inactivation and should be monitored in situ. Furthermore, the chemical and worker safety, and the legislative framework will determine the suitability of a disinfection technique. Current research often focuses on produce decontamination and to a lesser extent on preventing cross-contamination. Further research on a sanitizer’s efficacy in the washing water is recommended at the laboratory scale, in particular with experimental designs reflecting industrial conditions. Validation on the industrial scale is warranted to better understand the overall effects of a sanitizer.

  18. Recovery And Valorization Of Snakehead Fish Channa Striata Surimi Wash Water As Stock Albumin Tablet

    Directory of Open Access Journals (Sweden)

    Ikbal Syukroni

    2017-11-01

    Full Text Available Surimi washing process is aimed to concentrate the myofibril protein by removing catepsin enzyme fat pigment blood and sarcoplasmic protein which is soluble in wash water. The soluble subtances cause trouble environment if it was untreated. In addition recovery protein will give benefit both in reducing trouble environment and utilizing soluble protein as sources of albumin protein. The objectives of research were to recover albumin from snakehead fish surimi wash water and to valorize as stock albumin tablet. Recovery of albumin use 0.05 m ultrafiltration membrane and the valorization of albumin tablets was by direct compression. The protein band with molecular weight of 67.741 kDa on the retentate was detected as albumin. Concentration of protein recover by ultrafiltration membrane increased 89.98 and the albumin content 3.50.4 gdl. Based on the result of chemical composition and microbiology analysis albumin of snakehead surimi wash water appropriate with Indonesia National Standard SNI quality requirement about snakehead fish albumin extract. The best formulation in the preparation of surimi wash water albumin tablet was by using corn starch excipients with uniformity weight value 410.39 0.09 g hardness value 7.65 0.8 Kp uniformity size of tablet with diameter 1 cm and thickness 0.59 cm friability value 2.3 and disintregation time of the tablet is 2 minutes 16 second.

  19. Physical properties of cobia (Rachycentron canadum) surimi: effect of washing cycle at different salt concentrations.

    Science.gov (United States)

    Hamzah, N; Sarbon, N M; Amin, A M

    2015-08-01

    This study aimed to determine the effects of 2-5 wash cycles and the addition of tetrasodium pyrophosphate (TSPP) (0 %, 0.05 Surimi% and 0.1 % w/w)-with or without the addition of 0.4 % calcium chloride (CaCl2)-on the physical properties such as texture, colour, expressible moisture and microstructure of Cobia (Rachycentron canadum) surimi gel. The highest breaking force (484.85 g) was obtained with the addition 0.1 % TSPP alone on the fifth wash. However, a combination of 0.1 and 0.4 % CaCl2 in surimi gels at wash cycle 5 resulted in the highest degree of whiteness (86.8 %), as well as total expressible moisture (2.785 %) and deformation (17.11 mm). The highest surimi gel strength (6,923 g.mm) was obtained after three wash cycles with the addition of 0.1 % TSPP +0.4 % CaCl2. The physical properties of Cobia fish surimi gels were affected by the number of wash cycles and treatments with TSPP and CaCl2.

  20. Metal (Cu, Cd and Zn) removal and stabilization during multiple soil washing by saponin.

    Science.gov (United States)

    Gusiatin, Zygmunt Mariusz; Klimiuk, Ewa

    2012-01-01

    The influence of multiple saponin washing on copper, cadmium and zinc removal and stability in three types of soils (loamy sand, loam, silty clay) was investigated. Distribution of metals and their mobility measured as the ratio of exchangeable form to the sum of all fractions in soils was differential. After single washing the highest efficiency of metal removal was obtained in loamy sand (82-90%) and loam (67-88%), whereas the lowest in silty clay (39-62%). In loamy sand and loam metals had higher mobility factors (44-61% Cu, 60-76% Cd, and 68-84% Zn) compared to silty clay (9% Cu, 28% Cd and 36% Zn). Triplicate washing led to increase both efficiency of metal removal and percentage content of their stable forms. In consequence, fractional patterns for metals before and after treatment changed visibly as a result of their redistribution. Based on the redistribution index, the most stable metal (mainly in residual and organic fractions) after triplicate washing was Cu in loamy sand and loam. For silty clay contaminated with Cd, effective metal removal and its stabilization required a higher number of washings. Copyright © 2011 Elsevier Ltd. All rights reserved.

  1. Wastewater Treatment Model in Washing Stations for Vehicles Transporting Dangerous Goods

    Directory of Open Access Journals (Sweden)

    Robert Muha

    2004-09-01

    Full Text Available Car washing is a task performed by every passenger carowner more or less frequently, mainly to achieve a finer appearanceof the vehicle rather than for the need for cleanness.In the transport business, the owner's concern is to presentclean and orderly vehicles on the road as a relevant external elementof order, implying good corporate image to customers. Onthe other hand, in dangerous goods transportation there areother reasons requiring special technology of washing, applicableto the transport means used, depending on the change oftype of goods in carriage, the preliminary preparation of a vehicleto load the cargo, or to undergo maintenance.Water applied in the technology of washing collects the residueof goods carried in the vehicle and is polluted to such an extentthat it cannot be discharged into sewers - nor directly into awatercourse - without previous treatment.The paper presents a solution model and a sequence oftechnological procedures involved in an efficient treatment ofthe polluted wastewater in tank wash stations, in which mostlyvehicles carrying ADR goods are washed.

  2. A soil washing pilot plant for removing petroleum hydrocarbons from contaminated soils

    International Nuclear Information System (INIS)

    Toor, I.A.; Roehrig, G.R.

    1992-01-01

    A soil washing pilot plant was built and tested for its ability to remove petroleum hydrocarbons from certain soils. The ITEX soil washing pilot plant is a trailer mountable mobile unit which has a washing capacity of two tons per hour of contaminated soils. A benchscale study was carried out prior to the fabrication of the pilot plant. The first sample was contaminated with diesel fuel while the second sample was contaminated with crude oil. Various nonionic, cationic and anionic cleaning agents were evaluated for their ability to remove petroleum hydrocarbons from these materials. The nonionic cleaning agents were more successful in cleaning the soils in general. The ultimate surfactant choice was based on several factors including cost, biodegradability, cleaning efficiency and other technical considerations. The soil samples were characterized in terms of their particle size distributions. Commercial diesel fuel was carefully mixed in this sand to prepare a representative sample for the pilot plant study. Two pilot runs were made using this material. A multistage washing study was also conducted in the laboratory which indicates that the contamination level can be reduced to 100 ppm using only four stages. Because the pilot plant washing efficiency is twice as high, it is believed that ultimate contamination levels can be reduced to lower levels using the same number of stages. However, this hypothesis has not been demonstrated to date

  3. Tailoring Water, Sanitation, and Hygiene (WASH) Targets for Soil-Transmitted Helminthiasis and Schistosomiasis Control.

    Science.gov (United States)

    Campbell, Suzy J; Biritwum, Nana-Kwadwo; Woods, Geordie; Velleman, Yael; Fleming, Fiona; Stothard, J Russell

    2018-01-01

    The World Health Organization's (WHO) 2015-2020 Global Strategy on water, sanitation, and hygiene (WASH) and neglected tropical diseases (NTDs) encourages integration, whilst maintaining existing structured NTD investments, and acceleration towards Sustainable Development Goal (SDG) targets. Accordingly, SDG-associated and WASH-NTD indicators have been developed, commencing important intersectoral dialogue, alongside opportunities for future disease-specific refinements. The rationale for soil-transmitted helminthiasis (STH)- and schistosomiasis-specific WASH considerations, and a traffic-light figure, are presented here to indicate where current international definitions may, or may not, suffice. Certain unique aspects in control dynamics and parasitic lifecycles, however, necessitate additional implementation research with more appropriate measurement indicators developed to record programmatic interventions and to define strategic priorities more effectively. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  4. Performance Study of Screen-Printed Textile Antennas after Repeated Washing

    Directory of Open Access Journals (Sweden)

    Kazani I.

    2014-06-01

    Full Text Available The stability of wearable textile antennas after 20 reference washing cycles was evaluated by measuring the reflection coefficient of different antenna prototypes. The prototypes’ conductive parts were screen-printed on several textile substrates using two different silver-based conductive inks. The necessity of coating the antennas with a thermoplastic polyurethane (TPU coating was investigated by comparing coated with uncoated antennas. It is shown that covering the antennas with the TPU layer not only protects the screen-printed conductive area but also prevents delamination of the multilayered textile fabric substrates, making the antennas washable for up to 20 cycles. Furthermore, it is proven that coating is not necessary for maintaining antenna operation and this up to 20 washing cycles. However, connector detachment caused by friction during the washing process was the main problem of antenna performance degradation. Hence, other flexible, durable methods should be developed for establishing a stable electrical connection.

  5. Washing and Caustic Leaching of Hanford Tank Sludge: Results of FY 1998 Studies

    Energy Technology Data Exchange (ETDEWEB)

    GJ Lumetta; BM Rapko; J Liu; DJ Temer; RD Hunt

    1998-12-11

    Sludge washing and parametric caustic leaching tests were performed on sludge samples tiom five Hanford tanks: B-101, BX-1 10, BX-112, C-102, and S-101. These studies examined the effects of both dilute hydroxide washing and caustic leaching on the composition of the residual sludge solids. ` Dilute hydroxide washing removed from <1 to 25% of the Al, -20 to 45% of the Cr, -25 to 97% of the P, and 63 to 99% of the Na from the Hdord tank sludge samples examined. The partial removal of these elements was likely due to the presence of water-soluble sodium salts of aluminate, chromate, hydroxide, nitrate, nitrite, and phosphate, either in the interstitial liquid or as dried salts.

  6. Electroless copper plating on 3-mercaptopropyltriethoxysilane modified PET fabric challenged by ultrasonic washing

    International Nuclear Information System (INIS)

    Lu Yinxiang

    2009-01-01

    Electroless deposition of Cu on poly(ethylene terephthalate) (PET) fabric modified with 3-mercaptopropyltriethoxysilane was investigated. Morphology, composition, structure, thermal decomposing behavior of copper coating PET fabric after ultrasonic washing in water for 1 h were characterized by scanning electron microscopy (SEM), energy dispersive X-ray (EDX) analysis, X-ray photoelectron spectroscopy (XPS), Raman spectrometer, X-ray diffraction (XRD), and thermogravimetric analysis (TG), respectively. Copper plating on modified fabric has good adherence stability and high electric conductivity before and after ultrasonic washing, while copper coating fabric without modification is easily destroyed during the washing process, which leads to the textile changing from conductor to dielectric. As the copper weight on the treated fabric is 28 g/m 2 , the shielding effectiveness (SE) is more than 54 dB at frequency ranging from 0.01 MHz to 18 GHz.

  7. Suppression of deicing salt corrosion of weathering steel bridges by washing

    International Nuclear Information System (INIS)

    Hara, Shuichi; Miura, Masazumi; Uchiumi, Yasushi; Fujiwara, Toshiaki; Yamamoto, Masataka

    2005-01-01

    To elucidate the influences of deicing salts and high pressure (2-4 MPa) washing on the characteristics of the rust formed on weathering steel bridges, washing experiments have been carried out for three years. The rust was characterized by means of ion chromatography, X-ray diffraction and adsorption of N 2 . The rust thickness was measured, and also the rust weight per unit area of the steel surface was measured. It was found that water-soluble chloride accelerated the rate of corrosion because the rust particles grow by the chloride ions and micro-pore structure of the rust appeared by the chloride ions. Washing with water suppressed corrosion owing to the disappearance of chloride ions

  8. Assessment of Washing with Antioxidant on the Oxidative Stability of Fatty Fish Mince during Processing and Storage

    DEFF Research Database (Denmark)

    Eymard, Sylvie; Jacobsen, Charlotte; Baron, Caroline

    2010-01-01

    Fatty fish have been recognized as potential raw material for the production of surimi; however, they can easily oxidize. The ability of antioxidants added in the washing water to reduce oxidation during the washing and subsequent storage needs to be evaluated. Horse mackerel (Trachurus trachurus...... performed. Results indicated that the antioxidants were accumulated differently, but all antioxidants tested were able to prevent lipid oxidation in fatty fish mince during washing and subsequent storage. The ranking in terms of oxidative stability of the washed minces was CA = PG > SP > W. The antioxidants......) mince was washed three times with 3 volumes of cold water (W) or the antioxidant solutions caffeic acid (CA) or propyl gallate (PG), at concentrations of 100 mg/kg, or spermine (SP), at a concentration of 400 mg/kg. Accumulation of antioxidant in the mince at each washing step was evaluated...

  9. Effect of preputial washing on bacterial load and preservability of semen in Murrah buffalo bulls

    Directory of Open Access Journals (Sweden)

    G. S. Meena

    2015-06-01

    Full Text Available Aim: To study the effect of preputial washing on bacterial load, preservability and semen quality in Murrah buffalo bulls Materials and Methods: A total of 36 collections of three Murrah buffalo bulls maintained at Artificial Breeding Research Centre, ICAR-National Dairy Research Institute, Karnal, were collected at weekly intervals from each bull without preputial washing and latter ejaculates from same bull with preputial washing by infusing normal saline (0.85%, KMnO4 (0.02% and savlon (2.0% to first, second and third bull, respectively. The microbial load and semen quality were evaluated during different hours of storage at refrigerated temperature (0, 24 and 48 h and after thrawing of cryopreserved (at −196°C semen. Results: The results of preservation of semen at refrigerated temperature showed that bacterial load was markedly lower in ejaculates of bulls subjected to preputial washing. Semen preserved at refrigerator temperature and cryopreserved, the effect of washing solution was significant for individual motility (IM, non-eosiniphilic count, hypo-osmotic swelling reactivity (HOST, total plate count (TPC and acrosome integrity. KMnO4 was found to be the best in lowering bacterial load, sperm abnormalities and in improving semen quality such as motility, non-eosinophilic count, HOST and acrosome integrity even up to 48 h of preservation and cryopreserved semen. Effect of duration of preservation and stage of cryopreservation was also significant for IM, non-eosiniphilic count, HOST, sperm abnormalities and acrosome integrity. Conclusion: Overall the results suggested that preputial washing with KMnO4 solution improved the semen quality and reduced microbial load of Murrah buffalo bull’s semen preserved at refrigerated temperature and cryopreservation.

  10. Heavy metal removal by GLDA washing: Optimization, redistribution, recycling, and changes in soil fertility.

    Science.gov (United States)

    Wang, Guiyin; Zhang, Shirong; Xu, Xiaoxun; Zhong, Qinmei; Zhang, Chuer; Jia, Yongxia; Li, Ting; Deng, Ouping; Li, Yun

    2016-11-01

    Soil washing, an emerging method for treating soils contaminated by heavy metals, requires an evaluation of its efficiency in simultaneously removing different metals, the quality of the soil following remediation, and the reusability of the recycled washing agent. In this study, we employed N,N-bis (carboxymethyl)-l-glutamic acid (GLDA), a novel and readily biodegradable chelator to remove Cd, Pb, and Zn from polluted soils. We investigated the influence of washing conditions, including GLDA concentration, pH, and contact time on their removal efficiencies. The single factor experiments showed that Cd, Pb, and Zn removal efficiencies reached 70.62, 74.45, and 34.43% in mine soil at a GLDA concentration of 75mM, a pH of 4.0, and a contact time of 60min, and in polluted farmland soil, removal efficiencies were 69.12, 78.30, and 39.50%, respectively. We then employed response surface methodology to optimize the washing parameters. The optimization process showed that the removal efficiencies were 69.50, 88.09, and 40.45% in mine soil and 71.34, 81.02, and 50.95% in polluted farmland soil for Cd, Pb, and Zn, respectively. Moreover, the overall highly effective removal of Cd and Pb was connected mainly to their highly effective removal from the water-soluble, exchangeable, and carbonate fractions. GLDA-washing eliminated the same amount of metals as EDTA-washing, while simultaneously retaining most of the soil nutrients. Removal efficiencies of recycled GLDA were no >5% lower than those of the fresh GLDA. Therefore, GLDA could potentially be used for the rehabilitation of soil contaminated by heavy metals. Copyright © 2016 Elsevier B.V. All rights reserved.

  11. Decontamination of electronic waste-polluted soil by ultrasound-assisted soil washing.

    Science.gov (United States)

    Chen, Fu; Yang, Baodan; Ma, Jing; Qu, Junfeng; Liu, Gangjun

    2016-10-01

    Laboratorial scale experiments were performed to evaluate the efficacy of a washing process using the combination of methyl-β-cyclodextrin (MCD) and tea saponin (TS) for simultaneous desorption of hydrophobic organic contaminants (HOCs) and heavy metals from an electronic waste (e-waste) site. Ultrasonically aided mixing of the field contaminated soil with a combination of MCD and TS solutions simultaneously mobilizes most of polybrominated diphenyl ethers (PBDEs), polychlorinated biphenyls (PCBs), polycyclic aromatic hydrocarbons (PAHs), and the analyte metal (Pb, Cu, and Ni) burdens. It is found that 15 g/L MCD and 10 g/L TS is an efficient reagent combination reconciling extraction performance and reagent costs. Under these conditions, the removal efficiencies of HOCs and heavy metals are 93.5 and 91.2 %, respectively, after 2 cycles of 60-min ultrasound-assisted washing cycles. By contrast, 86.3 % of HOCs and 88.4 % of metals are removed from the soil in the absence of ultrasound after 3 cycles of 120-min washing. The ultrasound-assisted soil washing could generate high removal efficiency and decrease the operating time significantly. Finally, the feasibility of regenerating and reusing the spent washing solution in extracting pollutants from the soil is also demonstrated. By application of this integrated technology, it is possible to recycle the washing solution for a purpose to reduce the consumption of surfactant solutions. Collectively, it has provided an effective and economic treatment of e-waste-polluted soil.

  12. Voided urine versus bladder washing cytology for detection of urothelial carcinoma: which is better?

    Science.gov (United States)

    Keller, Anna Krarup; Jensen, Jørgen Bjerggaard

    2017-08-01

    Cytology is recommended as part of the follow-up of high-grade non-muscle-invasive bladder cancer (NMIBC). However, currently there are no solid guideline recommendations regarding the use of voided urine versus bladder washing for cytology as part of the diagnosis or follow-up of NMIBC. The aim of this study was to investigate whether the cytological outcome was equal regarding the two techniques. The authors reviewed all outpatient flexible cystoscopies carried out in their department in 2013. Patient records in the registry of pathology were examined and those with simultaneous urine and bladder washing cytology were included. Previous urothelial disease and positive histology within 3 months after the cystoscopy were registered. A total of 1458 patients had both voided urine and bladder washing cytology and were included in the study, of whom 643 (44%) had a history of urothelial disease. An equal outcome of urine and bladder washing cytology was found in 1447 patients (99.2%). For the remaining 11 patients, only four patients underwent further examinations based on cytology findings in addition to what had already been planned after cystoscopy. Of the included patients, 100 (6.9%) had a positive histological outcome within 3 months. In most patients, no relevant difference between voided urine and bladder washing cytology was observed. Therefore, if cytology is indicated, it is recommended to use the test that is most readily available locally. The additional gain in using both urine and bladder wash is minimal, and can therefore be discarded.

  13. Washing-electrokinetic Decontamination for Concrete Contaminated with Cobalt and Cesium

    International Nuclear Information System (INIS)

    Kim, Gye Nam; Yang, Byeong Il; Choi, Wang Kyu; Lee, Kune Woo; Hyeon, Jay Hyeok

    2009-01-01

    A great volume of radioactive concrete is generated during the operation and the decommissioning of nuclear facilities. The washing-electrokinetic technology in this study, which combined an electrokinetic method and a washing method, was developed to decontaminate the concrete generated in nuclear facilities. The results of only an electrokinetic decontamination for the concrete showed that cobalt was removed to below 1% from the concrete due to its high pH. Therefore, the washing electrokinetic technology was applied to lower the pH of the concrete. Namely, when the concrete was washed with 3 M of hydrochloric acid for 4 hours (0.17 day), the CaCO 3 in the concrete was decomposed into CO 2 and the pH of the concrete was reduced to 3.7, and the cobalt and cesium in the concrete were removed by up to 85.0% and 76.3% respectively. Next, when the washed concrete was decontaminated by the electrokinetic method with 0.01M of acetic acid in the 1L electrokinetic equipment for 14.83 days, the cobalt and the cesium in the concrete were both removed by up to 99.7% and 99.6% respectively. The removal efficiencies of the cobalt and cesium by 0.01M of acetic acid were increased more than those by 0.05M of acetic acid due to the increase of the concrete zeta potential. The total effluent volume generated from the washing-electrokinetic decontamination was 11.55L (7.2ml/g).

  14. Washing water treatment process for UF_6 cylinder by adjusting evaporation technology in a low temperature and low pressure

    International Nuclear Information System (INIS)

    Kim, Ki-tae; Ju, Young-jong; Cho, Nam-chan; Kim, Yun-kwan; Jin, Chang-suk

    2016-01-01

    The liquid waste is treated in this procedure; 1) Add NaOH to the liquid waste and filter the mixture with a screen. 2) Screened residue is dried and then stored in a uranium storage. 3) liquid part is moved to a storage tank and radioactivity is measured in the liquid. 5) If the concentration of radioactivity is lower than corresponding regulation limit, the liquid moved to a reaction tank and evaporated with additional low concentration HF in 105℃. 6) Radioactivity of distillate is measured and the value is lower than regulation, it is treated with a thermal decomposition process and discharged to the atmosphere in gas state. 7) Solid waste produced in the evaporation step is managed as solid nuclear waste. The treatment procedure mentioned above has disadvantageous points, producing large amount of solid waste as well as, high energy and chemical consumption. In this study, liquid waste from a real scaled cylinder wash process is applied to evaporation system to confirm feasibility of the application of evaporation and, to reduce waste production and energy consumption. Liquid radioactive wastewater from a real scaled UF6 cylinder wash process was applied to evaporation treatment system. Radioactive concentration in gross alpha was removed 99.9% in the evaporation system. And the concentration in distillate was lower than the discharge regulation. Removal of U-235 was 99.9% in the process. And 15 other kinds of radionuclides in the raw wastewater were removed completely. Secondary waste production of the evaporation system is 15g/L

  15. Experimental evaluation of washing for treatment of combustible plutonium-contaminated materials

    International Nuclear Information System (INIS)

    Wilkins, J.D.; Wisbey, S.J.

    1983-03-01

    Laboratory scale experiments have been carried out in order to assess the potential of washing as a method for removing plutonium from contaminated combustible wastes. A wide range of aqueous (eg 1 M HNO 3 , 1 M NaOH) and organic (1,1,2-trichlorotrifluoroethane) reagents have been investigated. Both synthetically contaminated and real wastes have been investigated. The preferred wash reagent has been identified as 1 M sodium hydroxide solution; plutonium recoveries of ca.80 to 90% can be achieved. (author)

  16. Test installation for studying erosion-corrosion of metals for coal washing plants

    Energy Technology Data Exchange (ETDEWEB)

    Hoey, G. R.; Dingley, W.; Wiles, C. T.

    1979-02-15

    A test installation was constructed for investigating erosion-corrosion of metals by coal-water slurries. Erosion-corrosion tests of mild steel panels were conducted using slurries of alundum, quartz, washed coal and coal refuse. Wear rates were found to depend on type of abrasive, particle size and water conductivity and were reduced by cathodic protection and inhibitors. Cathodic protection of mild steel in coal slurries containing sulphate ion reduced wear by 90% and 86% for stationary and rotating panels, respectively. This study has demonstrated that the successful application of corrosion control techniques would reduce metal wastage in coal washing plants. The test installation is considered suitable for developing the techniques.

  17. Social determinants of good hand-washing practice (GHP) among adolescents in a rural Indian community.

    Science.gov (United States)

    Dobe, Madhumita; Mandal, Ram Narayan; Jha, Ayan

    2013-01-01

    A cross-sectional study was conducted in 5 randomly selected villages to assess prevalence of good hand-washing practice (GHP) among adolescents, and describe the social determinants. The prevalence of adolescent GHP was 32.1% (95% CI = 27.1, 37.1). Logistic regression established 5 significant positive predictors-maternal GHP, presence of sanitary latrine, availability of soap at hand-washing locations, in-house water supply, and higher per capita income. Our research provides a scope for better understanding of the socioeconomic determinants of GHP in a rural Indian setting, and may find implications in the Total Sanitation Campaign launched by Government of India.

  18. Brain washing : Transport of cerebral extracellular fluids and solutes

    NARCIS (Netherlands)

    Bedussi, B.

    2017-01-01

    Regulation of extracellular volume and fluid composition provides a robust microenvironment for brain cells. In peripheral tissue, fluid surplus and solutes are removed from the interstitium via drainage into lymphatic channels. Since the central nervous system lacks a proper lymphatic vasculature,

  19. Filtration of Runoff From Pressure Washing Vessel Hull in Drydock

    Science.gov (United States)

    1995-09-01

    the most cost-effective treatment system for particular waste streams, especially heavy metals such as Tributyltin ( TBT ), Lead, Zinc, and Copper...solids, sediment, spent grit blast, sea growth, and toxic metals. The chemical and physical parameters of the material were defined to decide the...ported the original hypothesis that little dissolved matter was present in the water. Furthermore, it suggested that TBT , if present, was unlikely to be

  20. Assessing the effect of sodium dichloroisocyanurate concentration on transfer of Salmonella enterica serotype Typhimurium in wash water for production of minimally processed iceberg lettuce (Lactuca sativa L.).

    Science.gov (United States)

    Maffei, D F; Sant'Ana, A S; Monteiro, G; Schaffner, D W; Franco, B D G M

    2016-06-01

    This study evaluated the impact of sodium dichloroisocyanurate (5, 10, 20, 30, 40, 50 and 250 mg l(-1) ) in wash water on transfer of Salmonella Typhimurium from contaminated lettuce to wash water and then to other noncontaminated lettuces washed sequentially in the same water. Experiments were designed mimicking the conditions commonly seen in minimally processed vegetable (MPV) processing plants in Brazil. The scenarios were as follows: (1) Washing one inoculated lettuce portion in nonchlorinated water, followed by washing 10 noninoculated portions sequentially. (2) Washing one inoculated lettuce portion in chlorinated water followed by washing five noninoculated portions sequentially. (3) Washing five inoculated lettuce portions in chlorinated water sequentially, followed by washing five noninoculated portions sequentially. (4) Washing five noninoculated lettuce portions in chlorinated water sequentially, followed by washing five inoculated portions sequentially and then by washing five noninoculated portions sequentially in the same water. Salm. Typhimurium transfer from inoculated lettuce to wash water and further dissemination to noninoculated lettuces occurred when nonchlorinated water was used (scenario 1). When chlorinated water was used (scenarios 2, 3 and 4), no measurable Salm. Typhimurium transfer occurred if the sanitizer was ≥10 mg l(-1) . Use of sanitizers in correct concentrations is important to minimize the risk of microbial transfer during MPV washing. In this study, the impact of sodium dichloroisocyanurate in the wash water on transfer of Salmonella Typhimurium from inoculated lettuce to wash water and then to other noninoculated lettuces washed sequentially in the same water was evaluated. The use of chlorinated water, at concentration above 10 mg l(-1) , effectively prevented Salm. Typhimurium transfer under several different washing scenarios. Conversely, when nonchlorinated water was used, Salm. Typhimurium transfer occurred in

  1. Estimated ground-water recharge from streamflow in Fortymile Wash near Yucca Mountain, Nevada

    International Nuclear Information System (INIS)

    Savard, C.S.

    1998-01-01

    The two purposes of this report are to qualitatively document ground-water recharge from stream-flow in Fortymile Wash during the period 1969--95 from previously unpublished ground-water levels in boreholes in Fortymile Canyon during 1982--91 and 1995, and to quantitatively estimate the long-term ground-water recharge rate from streamflow in Fortymile Wash for four reaches of Fortymile Wash (Fortymile Canyon, upper Jackass Flats, lower Jackass Flats, and Amargosa Desert). The long-term groundwater recharge rate was estimated from estimates of the volume of water available for infiltration, the volume of infiltration losses from streamflow, the ground-water recharge volume from infiltration losses, and an analysis of the different periods of data availability. The volume of water available for infiltration and ground-water recharge in the four reaches was estimated from known streamflow in ephemeral Fortymile Wash, which was measured at several gaging station locations. The volume of infiltration losses from streamflow for the four reaches was estimated from a streamflow volume loss factor applied to the estimated streamflows. the ground-water recharge volume was estimated from a linear relation between infiltration loss volume and ground-water recharge volume for each of the four reaches. Ground-water recharge rates were estimated for three different periods of data availability (1969--95, 1983--95, and 1992--95) and a long-term ground-water recharge rate estimated for each of the four reaches

  2. Reduction of microbial counts during kitchen scale washing and sanitization of salad vegetables

    NARCIS (Netherlands)

    Ssemanda, James Noah; Joosten, Han; Bagabe, Mark Cyubahiro; Zwietering, Marcel H.; Reij, Martine W.

    2018-01-01

    Washing with or without sanitizers is one of the important steps designated to reduce or eliminate microbial hazards in fresh vegetables but the settings, conditions and effectiveness of this step remain contentious. In this study, we investigated kitchen scale salad preparation practices in a field

  3. Preliminary gravity and magnetic models across Midway Valley and Yucca Wash, Yucca Mountain, Nevada

    International Nuclear Information System (INIS)

    Ponce, D.A.; Langenheim, V.E.

    1994-01-01

    Detailed gravity and ground magnetic data collected along ten traverses across Midway Valley and Yucca Wash on the eastern flank of Yucca Mountain in southwest Nevada are interpreted. These data were collected as part of an effort to evaluate faulting in the vicinity of proposed surface facilities for a potential nuclear waste repository at Yucca Mountain. Geophysical data show that Midway Valley is bounded by large gravity and magnetic anomalies associated with the Bow Ridge and Paintbrush Canyon faults, on the west side of Exile Hill and on the west flank of Fran Ridge, respectively. In addition, Midway Valley itself is characterized by a number of small-amplitude anomalies that probably reflect small-scale faulting beneath Midway Valley. Gravity and magnetic data across the northwest trending Yucca Wash and the inferred Yucca Wash fault indicate no major vertical offsets greater than 100 m using a density contrast of 0.2 to 0.3 g/cm 3 along the proposed Yucca Wash fault. In addition, a broad magnetic high coincides with the approximate location of the hydrologic gradient and probably reflects moderately magnetic Topopah Spring Tuff or lavas in the Calico Hills Formation

  4. Effectiveness of hand washing on the removal of iron oxide nanoparticles from human skin ex vivo.

    Science.gov (United States)

    Lewinski, Nastassja A; Berthet, Aurélie; Maurizi, Lionel; Eisenbeis, Antoine; Hopf, Nancy B

    2017-08-01

    In this study, the effectiveness of washing with soap and water in removing nanoparticles from exposed skin was investigated. Dry, nanoscale hematite (α-Fe 2 O 3 ) or maghemite (γ-Fe 2 O 3 ) powder, with primary particle diameters between 20-30 nm, were applied to two samples each of fresh and frozen ex vivo human skin in two independent experiments. The permeation of nanoparticles through skin, and the removal of nanoparticles after washing with soap and water were investigated. Bare iron oxide nanoparticles remained primarily on the surface of the skin, without penetrating beyond the stratum corneum. Skin exposed to iron oxide nanoparticles for 1 and 20 hr resulted in removal of 85% and 90%, respectively, of the original dose after washing. In the event of dermal exposure to chemicals, removal is essential to avoid potential local irritation or permeation across skin. Although manufactured at an industrial scale and used extensively in laboratory experiments, limited data are available on the removal of engineered nanoparticles after skin contact. Our finding raises questions about the potential consequences of nanoparticles remaining on the skin and whether alternative washing methods should be proposed. Further studies on skin decontamination beyond use of soap and water are needed to improve the understanding of the potential health consequences of dermal exposure to nanoparticles.

  5. Extraction agents for the removal of polycyclic aromatic hydrocarbons (PAHs) from soil in soil washing technologies

    International Nuclear Information System (INIS)

    Lau, Ee Von; Gan, Suyin; Ng, Hoon Kiat; Poh, Phaik Eong

    2014-01-01

    Polycyclic aromatic hydrocarbons (PAHs) in soil have been recognised as a serious health and environmental issue due to their carcinogenic, mutagenic and teratogenic properties. One of the commonly employed soil remediation techniques to clean up such contamination is soil washing or solvent extraction. The main factor which governs the efficiency of this process is the solubility of PAHs in the extraction agent. Past field-scale soil washing treatments for PAH-contaminated soil have mainly employed organic solvents or water which is either toxic and costly or inefficient in removing higher molecular weight PAHs. Thus, the present article aims to provide a review and discussion of the alternative extraction agents that have been studied, including surfactants, biosurfactants, microemulsions, natural surfactants, cyclodextrins, vegetable oil and solution with solid phase particles. These extraction agents have been found to remove PAHs from soil at percentages ranging from 47 to 100% for various PAHs. -- Highlights: • The alternative and advancement in extraction agents to remove PAHs from soil using soil washing technology is summarised. • The soil regulations for PAH level in various countries are summarized for reference to researchers. • The concentration levels of PAHs in soil at present and the need for soil remediation is presented. -- The efficiency of the extraction agent plays a significant role in soil washing of PAH-contaminated soil

  6. Effect of health education on hand washing of mothers of under five ...

    African Journals Online (AJOL)

    Diarrhea is a leading cause of morbidity and mortality in children under five years of age in middle and low income countries. Nearly one in five child deaths is due to diarrhea and globally it accounts for 1.5million deaths annually. Although hand washing with soap is effective for the prevention of transmission of diarrhea ...

  7. Simulation of flow in the unsaturated zone beneath Pagany Wash, Yucca Mountain

    International Nuclear Information System (INIS)

    Kwicklis, E.M.; Healy, R.W.; Flint, A.L.

    1994-01-01

    A one-dimensional numerical model was created to simulate water movement beneath Pagany Wash, Yucca Mountain, Nevada. Model stratigraphy and properties were based on data obtained from boreholes UE-25 UZ No. 4 and UE-25 UZ No. 5, which was drilled in the alluvial channel and bedrock sideslope of Pagany Wash. Although unable to account for multidimensional or preferential flowpaths beneath the wash, the model proved a useful conceptual tool with which to develop hypotheses and, in some cases, provide bounding calculations. The model indicated that liquid flux decreases with depth in the upper 120 m beneath the wash, with fluxes of several tens mm/yr in the nonwelded base of the Tiva Canyon Member and fluxes on the order of a tenth mm/yr in the upper Topopah Spring Member. Capillary barrier effects were indicated by the model to significantly delay the entry of large fluxes into the potential repository horizon during periods of increasing net infiltration, and to inhibit rapid drainage of water from the nonwelded and bedded intervals into the potential repository horizon during periods of moisture redistribution. Lateral moisture redistribution can be expected to be promoted by these effects

  8. Effect of washing and boiling on residues of pirimiphos-methyl in soybeans

    International Nuclear Information System (INIS)

    Sulistiawaty, M.; Anwar, E.

    1996-01-01

    The residues of pirimiphos-methyl (0-2-diethylamino-6-methyl-pyrimidine-4-il-o-dimethyl phos-phorothioate) in soybean grains were studied using 14 C-labelled-pirimiphos-methyl. Jute sock containing soybean grains were sprayed with pirimiphos-methyl and then stored at room temperature. The results indicated than residues of pirimiphos-methyl in soybeans before washing, after washing, and after washing + boiling at 0 week storage were: 1.0, 0.42, and 0.01%: then increased to 42.01, 30.75, and 10.02%, respectively, after 12 weeks, and finally decreased to 38.33, 27.01, and 6.10%, respectively, after 24 weeks storage. The residues of pirimiphos-methyl in washing water at 0 week storage was 0.41%, then increased to 8.01% after 24 weeks storage. The percentage was calculated based on the amount of residue found compared to the initial pirimiphos-methyl used. (author)

  9. Anaerobic treatment of distillery spent wash - a study on upflow anaerobic fixed film bioreactor.

    Science.gov (United States)

    Acharya, Bhavik K; Mohana, Sarayu; Madamwar, Datta

    2008-07-01

    Anaerobic digestion of wastewater from a distillery industry having very high COD (1,10,000-1,90,000 mg/L) and BOD (50,000-60,000 mg/L) was studied in a continuously fed, up flow fixed film column reactor using different support materials such as charcoal, coconut coir and nylon fibers under varying hydraulic retention time and organic loading rates. The seed consortium was prepared by enrichment with distillery spent wash in a conventional type reactor having working capacity of 3 L and was used for charging the anaerobic column reactor. Amongst the various support materials studied the reactor having coconut coir could treat distillery spent wash at 8d hydraulic retention time with organic loading rate of 23.25 kg COD m(-3)d(-1) leading to 64% COD reduction with biogas production of 7.2 m3 m(-3)d(-1) having high methane yield without any pretreatment or neutralization of the distillery spent wash. This study indicates fixed film biomethanation of distillery spent wash using coconut coir as the support material appears to be a cost effective and promising technology for mitigating the problems caused by distillery effluent.

  10. Incremental yield of bronchial washing for diagnosing smear-negative pulmonary tuberculosis

    Directory of Open Access Journals (Sweden)

    Alonso Soto

    2013-08-01

    Full Text Available OBJECTIVE To assess the increased diagnostic yield for pulmonary tuberculosis using bronchial washing cultures compared with sputum cultures. METHODS Study conducted with 61 adults in Lima, Peru, from January 2006 to December 2007. The yield of sputum cultures was compared with the yield of acid-fast bacilli smears and cultures of bronchial washing for diagnosing pulmonary tuberculosis in suspected cases of clinical tuberculosis with negative acid fast bacilli sputum smears. RESULTS Twenty seven (95%CI 32;58 of the cases were eventually diagnosed with smear-negative pulmonary tuberculosis. Bronchial washing samples detected 23 (95%CI 72;99 of the smear-negative pulmonary tuberculosis cases compared with 15 (95%CI 37;74 for sputum cultures (p = 0.02. The incremental diagnostic yield of acid fast bacilli smear and culture of bronchial washing specimens over sputum culture was 44% (95%CI 25;65. CONCLUSIONS In function of the epidemiological context and the resources available, bronchoscopy should be deployed as part of a comprehensive work up that optimizes smear-negative pulmonary tuberculosis diagnosis and minimizes risk and costs.

  11. PERCHLORATE UPTAKE BY SALT CEDAR (TAMARIX RAMOSISSIMA) IN THE LAS VEGAS WASH RIPARIAN ECOSYSTEM

    Science.gov (United States)

    Perchlorate ion (CIO4-) has been identified in samples of dormant salt cedar (Tamarix ramosissima) growing in the Las vegas Wash. Perchlorate is an oxidenat, but its reduction is kineticaly hindered. CXoncern over thyrpoid effects caused the Environmental Protection Agency (EPA...

  12. 78 FR 54449 - Subzone 8I, Authorization of Production Activity, Whirlpool Corporation (Washing Machines); Clyde...

    Science.gov (United States)

    2013-09-04

    ... DEPARTMENT OF COMMERCE Foreign-Trade Zones Board [B-43-2013] Subzone 8I, Authorization of Production Activity, Whirlpool Corporation (Washing Machines); Clyde and Green Springs, Ohio On May 1, 2013, Whirlpool Corporation (Whirlpool) submitted a notification of proposed production activity to the Foreign...

  13. Influence of washing time on residual contamination of carcasses sprayed with lauric acid-potassium hydroxide.

    Science.gov (United States)

    A series of experiments were conducted to examine reductions in bacterial contamination of broiler carcasses washed for various times in a spray cabinet with a 2% lauric acid (LA)-1% potassium hydroxide (KOH) (w/v) solution. Forty eviscerated carcasses and 5 ceca were obtained from the processing l...

  14. Role of lauric acid-potassium hydroxide concentration on bacterial contamination of spray washed broiler carcasses

    Science.gov (United States)

    A series of experiments were conducted to examine reductions in bacterial contamination of broiler carcasses washed in a spray cabinet with various concentrations of lauric acid (LA)-potassium hydroxide (KOH) solutions. Fifty eviscerated carcasses and 5 ceca were obtained from the processing line of...

  15. Geopolymerisation of silt generated from construction and demolition waste washing plants.

    Science.gov (United States)

    Lampris, C; Lupo, R; Cheeseman, C R

    2009-01-01

    Recycling plants that size, sort and wash construction and demolition waste can produce high quality aggregate. However, they also produce up to 80ton per hour of filter cake waste containing fine (waste and normally landfilled. This research investigated the potential to form geopolymers containing silt, which would allow this problematic waste to be beneficially reused as aggregate. This would significantly improve the economic viability of recycling plants that wash wastes. Silt filter cakes have been collected from a number of aggregate washing plants operating in the UK. These were found to contain similar aluminosilicate crystalline phases. Geopolymer samples were produced using silt and silt mixed with either metakaolin or pulverised fuel ash (PFA). Silt geopolymers cured at room temperature had average 7-day compressive strengths of 18.7MPa, while partial substitution of silt by metakaolin or PFA increased average compressive strengths to 30.5 and 21.9MPa, respectively. Curing specimens for 24h at 105 degrees C resulted in a compressive strength of 39.7MPa and microstructural analysis confirmed the formation of dense materials. These strengths are in excess of those required for materials to be used as aggregate, particularly in unbound applications. The implications of this research for the management of waste silt at construction and demolition waste washing plants are discussed.

  16. Application of washed rumen technique for rapid determination of fasting heat production in steers

    Science.gov (United States)

    Two experiments were conducted to evaluate the use of a washed rumen technique as an alternative approach for determining fasting HP in cattle. In Exp. 1, 8 Holstein steers (322±30 kg) were adapted to a cubed alfalfa-based diet (1.5xNEm) for 10 d. After which steers were placed into individual hea...

  17. Soil remediation using a coupled process: soil washing with surfactant followed by photo-Fenton oxidation

    International Nuclear Information System (INIS)

    Villa, Ricardo D.; Trovo, Alam G.; Nogueira, Raquel F. Pupo

    2010-01-01

    In the present work the use of a coupled process, soil washing and photo-Fenton oxidation, was investigated for remediation of a soil contaminated with p,p'-DDT (DDT) and p,p'-DDE (DDE), and a soil artificially contaminated with diesel. In the soil washing experiments, Triton X-100 (TX-100) aqueous solutions were used at different concentrations to obtain wastewaters with different compositions. Removal efficiencies of 66% (DDT), 80% (DDE) and 100% (diesel) were achieved for three sequential washings using a TX-100 solution strength equivalent to 12 times the effective critical micelle concentration of the surfactant (12 CMC eff ). The wastewater obtained was then treated using a solar photo-Fenton process. After 6 h irradiation, 99, 95 and 100% degradation efficiencies were achieved for DDT, DDE and diesel, respectively. In all experiments, the concentration of dissolved organic carbon decreased by at least 95%, indicating that residual concentration of contaminants and/or TX-100 in the wastewater was very low. The co-extraction of metals was also evaluated. Among the metals analyzed (Pb, Cr, Ni, Cu, Cd, Mn and Co), only Cr and Mn were detected in the wastewater at concentrations above the maximum value permitted by current Brazilian legislation. The effective removal of contaminants from soil by the TX-100 washing process, together with the high degradation efficiency of the solar photo-Fenton process, suggests that this procedure could be a useful option for soil remediation.

  18. Soil remediation using a coupled process: soil washing with surfactant followed by photo-Fenton oxidation

    Energy Technology Data Exchange (ETDEWEB)

    Villa, Ricardo D., E-mail: ricardovilla@ufmt.br [UNESP - Sao Paulo State University, Institute of Chemistry of Araraquara, Department of Analytical Chemistry, P.O. Box 355, 14801-970 Araraquara, SP (Brazil); Trovo, Alam G., E-mail: alamtrovo@smail.ufsm.br [UNESP - Sao Paulo State University, Institute of Chemistry of Araraquara, Department of Analytical Chemistry, P.O. Box 355, 14801-970 Araraquara, SP (Brazil); Nogueira, Raquel F. Pupo, E-mail: nogueira@iq.unesp.br [UNESP - Sao Paulo State University, Institute of Chemistry of Araraquara, Department of Analytical Chemistry, P.O. Box 355, 14801-970 Araraquara, SP (Brazil)

    2010-02-15

    In the present work the use of a coupled process, soil washing and photo-Fenton oxidation, was investigated for remediation of a soil contaminated with p,p'-DDT (DDT) and p,p'-DDE (DDE), and a soil artificially contaminated with diesel. In the soil washing experiments, Triton X-100 (TX-100) aqueous solutions were used at different concentrations to obtain wastewaters with different compositions. Removal efficiencies of 66% (DDT), 80% (DDE) and 100% (diesel) were achieved for three sequential washings using a TX-100 solution strength equivalent to 12 times the effective critical micelle concentration of the surfactant (12 CMC{sub eff}). The wastewater obtained was then treated using a solar photo-Fenton process. After 6 h irradiation, 99, 95 and 100% degradation efficiencies were achieved for DDT, DDE and diesel, respectively. In all experiments, the concentration of dissolved organic carbon decreased by at least 95%, indicating that residual concentration of contaminants and/or TX-100 in the wastewater was very low. The co-extraction of metals was also evaluated. Among the metals analyzed (Pb, Cr, Ni, Cu, Cd, Mn and Co), only Cr and Mn were detected in the wastewater at concentrations above the maximum value permitted by current Brazilian legislation. The effective removal of contaminants from soil by the TX-100 washing process, together with the high degradation efficiency of the solar photo-Fenton process, suggests that this procedure could be a useful option for soil remediation.

  19. Efficacy of household washing treatments for the control of Listeria monocytogenes on salad vegetables.

    Science.gov (United States)

    Nastou, Aikaterini; Rhoades, Jonathan; Smirniotis, Petros; Makri, Ioanna; Kontominas, Michael; Likotrafiti, Eleni

    2012-10-15

    The efficacy of household decontamination methods at reducing Listeria monocytogenes on fresh lettuce (Lactuca sativa), cucumber (Cucumis sativus) and parsley (Petroselinum sativum) was studied. Inoculated vegetable pieces were immersed in washing solutions and surviving L. monocytogenes enumerated. Parameters investigated were storage temperature prior to washing, dipping water temperature, agitation, acetic acid concentration and immersion time. The results indicated that the storage temperature significantly affects the efficacy of dipping vegetables in water for the control of L. monocytogenes, as the reduction in count was greatest when products had been stored at cooler temperatures. Decontamination with acetic acid (up to 2.0% v/v) was shown to have some effect in most cases, but the highest observed decrease in count was 2.6 log cfu/g. Experiments investigating the effect of exposure time to acetic acid (0.5% and 1.0% v/v, up to 30 min immersion) indicated that immersing the vegetables for more than 10 min is of minimal benefit. The most significant factor affecting washing and decontamination efficacy was the vegetable itself: L. monocytogenes colonizing cucumber epidermis was far more resistant to removal by washing and to acid treatment than that on the leafy vegetables, and L. monocytogenes on parsley was the most susceptible. This shows that published decontamination experiments (often performed with lettuce) cannot necessarily be extrapolated to other vegetables. Copyright © 2012 Elsevier B.V. All rights reserved.

  20. Hydrologic impacts of climate change and urbanization in Las Vegas Wash Watershed, Nevada

    Science.gov (United States)

    In this study, a cell-based model for the Las Vegas Wash (LVW) Watershed in Clark County, Nevada, was developed by combining the traditional hydrologic modeling methods (Thornthwaite’s water balance model and the Soil Conservation Survey’s Curve Number method) with the pixel-base...

  1. The Effect of Washing and Peeling on Reduction of Dithiocarbamates Residues in Cucumber and Tomato

    Directory of Open Access Journals (Sweden)

    Mohammad Reza Mehrasebi

    2016-03-01

    Full Text Available Background: Dithiocarbamates, the main group of fungicides, are used to control about 400 pathogens in more than 70 crops. These pesticides are widely applied to crops including potato, cereal, apple, pear and leafy vegetables throughout the world since 1960. From the late 1980s, using these fungicides has caused much debate among regulators about their long-term effects on consumers and occupational users. Method: In this study the residues of Dithiocarbamates in cucumber and tomato using the colorimetric method (Keppel method was measured. Respectively 80 and 45 samples of greenhouse cucumber and tomato were collected from Zanjan vegetables center in autumns and winter 2013. The samples were analyzed in 4 treatments of: unwashed, washing with water, washing whit detergent and peeling. Result: The results showed that the average concentration of Dithiocarbamates residues in unwashed greenhouse cucumber and tomatoes were 384.5 µg/kg and 65 µg/kg respectively. 35% and 5% of unwashed and water washed cucumber and tomato samples (respectively had higher Dithiocarbamates residue than MRL recommended by Institute of Standards and Industrial Research of Iran (0.5mg/kg. Conclusion: The treatments of washing and peeling had significant effect on the reduction of Dithiocarbamates residues in the all samples.

  2. Raffinate wash of second cycle solvent in the recovery of uranium from phosphate rock

    International Nuclear Information System (INIS)

    Abodishish, H.A.; Ritchey, R.W.

    1983-01-01

    Precipitation of Fe 3 HN 4 H 8 (PO 4 ) 6 is prevented in the second cycle extractor, in a two cycle uranium recovery process, by washing ammonia laden organic solvent stream, from the second cycle stripper, with first cycle raffinate iron stream containing phosphoric acid, prior to passing the solvent stream into the second cycle extractor

  3. Inspections of Hand Washing Supplies and Hand Sanitizer in Public Schools

    Science.gov (United States)

    Ramos, Mary M.; Blea, Mary; Trujillo, Rebecca; Greenberg, Cynthia

    2010-01-01

    Hand washing and hand antisepsis are proven infection control measures in the school setting, yet barriers such as lack of soap, paper towels, and hand sanitizer can hinder compliance. This pilot study measured the prevalence of hand cleaning supplies in public schools. Ten school districts (93 schools) participated in school nurse inspections. In…

  4. Electrodialytic versus acid extraction of heavy metals from soil washing residue

    DEFF Research Database (Denmark)

    Jensen, Pernille E.; Ottosen, Lisbeth M.; Allard, Bert

    2012-01-01

    The feasibility of electrodialytic remediation (EDR) for treatment of suspended sludge after soil washing is in focus in the present paper. Five industrially contaminated soils were treated in laboratory scale remediation experiments, and the toxic elements of the investigation were: As, Cd, Cu, ...

  5. Enhanced post wash retention of combed DNA molecules by varying multiple combing parameters.

    Science.gov (United States)

    Yadav, Hemendra; Sharma, Pulkit

    2017-11-01

    Recent advances in genomics have created a need for efficient techniques for deciphering information hidden in various genomes. Single molecule analysis is one such technique to understand molecular processes at single molecule level. Fiber- FISH performed with the help of DNA combing can help us in understanding genetic rearrangements and changes in genome at single DNA molecule level. For performing Fiber-FISH we need high retention of combed DNA molecules post wash as Fiber-FISH requires profuse washing. We optimized combing process involving combing solution, method of DNA mounting on glass slides and coating of glass slides to enhance post-wash retention of DNA molecules. It was found that average number of DNA molecules observed post-wash per field of view was maximum with our optimized combing solution. APTES coated glass slides showed lesser retention than PEI surface but fluorescent intensity was higher in case of APTES coated surface. Capillary method used to mount DNA on glass slides also showed lesser retention but straight DNA molecules were observed as compared to force flow method. Copyright © 2017 Elsevier Inc. All rights reserved.

  6. Effect of acid washing on pyrolysis of Cladophora socialis alga in microtubing reactor

    International Nuclear Information System (INIS)

    Ly, Hoang Vu; Kim, Seung-Soo; Kim, Jinsoo; Choi, Jae Hyung; Woo, Hee Chul

    2015-01-01

    Highlights: • Pyrolysis of macroalgae Cladophora socialis was conducted in micro tubular reactor. • Acid washing affected the pyrolysis behavior of Cladophora socialis. • Pyrolysis of raw and acid washed C. socialis produced bio-oils with different compositions. • Pyrolysis reaction pathway was from C. socialis to liquid and then to gas (C_1–C_4). - Abstract: Cladophora socialis is a unique macroalga that is widely grown in the coastal regions of Vietnam. In this work, the pyrolysis characteristics of C. socialis were evaluated using thermogravimetric analysis (TGA) and pyrolysis in a tubing reactor. Macroalgae have a high content of inorganic compounds. These compounds result in high char content during pyrolysis of the macroalgae, which degrades the quality of the product bio-oil. In order to study this effect, C. socialis was demineralized by acid washing to remove the inorganic compounds. The effect of acid washing on the pyrolysis product distribution and the selectivity of composition in pyrolysis oil was carefully investigated. The kinetic parameters and the primary reaction pathways were also determined based on experimental data using nonlinear least-squares regression assuming a first-order kinetics model.

  7. Flexographic newspaper deinking : treatment of wash filtrate effluent by membrane technology

    Science.gov (United States)

    B. Chabot; G.A. Krishnagopalan; S. Abubakr

    1999-01-01

    Ultrafiltration was investigated as a means to remove flexographic ink pigments from wash filtrate effluent generated from various mixtures of flexographic and offset old newspapers from deinking operations. Membrane separation efficiency was assessed from permeate flux, fouling rate, and ease of membrane regeneration (cleaning). Ultrafiltration was capable of...

  8. 7 CFR 57.801 - Nest run or washed ungraded eggs.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Nest run or washed ungraded eggs. 57.801 Section 57... AND STANDARDS UNDER THE AGRICULTURAL MARKETING ACT OF 1946 AND THE EGG PRODUCTS INSPECTION ACT (CONTINUED) INSPECTION OF EGGS (EGG PRODUCTS INSPECTION ACT) Regulations Governing the Inspection of Eggs...

  9. Inappropriate shock delivery by implantable cardioverter defibrillator due to electrical interference with washing machine.

    Science.gov (United States)

    Chongtham, Dhanaraj Singh; Bahl, Ajay; Kumar, Rohit Manoj; Talwar, K K

    2007-05-31

    We report a patient with hypertrophic cardiomyopathy who received an inappropriate implantable cardioverter defibrillator shock due to electrical interference from a washing machine. This electrical interference was detected as an episode of ventricular fibrillation with delivery of shock without warning symptoms.

  10. Evaluation of radiocaesium wash-off by soil erosion from various land uses using USLE plots

    International Nuclear Information System (INIS)

    Yoshimura, Kazuya; Onda, Yuichi; Kato, Hiroaki

    2015-01-01

    Radiocaesium wash-off associated with soil erosion in different land use was monitored using USLE plots in Kawamata, Fukushima Prefecture, Japan after the Fukushima Dai-ichi Nuclear Power Plant accident. Parameters and factors relating to soil erosion and 137 Cs concentration in the eroded soil were evaluated based on the field monitoring and presented. The erosion of fine soil, which is defined as the fraction of soil overflowed along with discharged water from a sediment-trap tank, constituted a large proportion of the discharged radiocaesium. This indicated that the quantitative monitoring of fine soil erosion is greatly important for the accurate evaluation of radiocaesium wash-off. An exponential relationship was found between vegetation cover and the amount of eroded soil. Moreover, the radiocaesium concentrations in the discharged soil were greatly affected by the land use. These results indicate that radiocaesium wash-off related to vegetation cover and land use is crucially important in modelling radiocaesium migration. - Highlights: • Fine soil erosion showed large impact on radiocaesium wash-off. • Exponential relationship was found between vegetation cover and eroded soil. • Radiocaesium concentration in the discharged soil was depending on land use

  11. Exploratory Disposal and Reuse Feasibility Analysis of Winter Maintenance Wash Water.

    Science.gov (United States)

    Ullinger, Heather L; Kennedy, Marla J; Schneider, William H; Miller, Christopher M

    2016-01-01

    The Ohio Department of Transportation has more than 60 facilities without sewer access generating approximately 19 million gallons of winter maintenance wash water. Off-site disposal is costly, creating the need for sustainable management strategies. The objective of this study was to conduct an exploratory feasibility analysis to assess wash water disposal and potential reuse as brine. Based on a comprehensive literature review and relevant environmental chemistry, a sampling protocol consisting of 31 water quality constituents was utilized for monthly sampling at three geographically distinct Ohio Department of Transportation garages during the winter of 2012. Results were compared to local disposal and reuse guidance limits. Three constituents, including a maximum copper concentration of 858 ppb, exceeded disposal limits, and many constituents also failed to meet reuse limits. Some concentrations were orders of magnitude higher than reuse limits and suggest pre-treatment would be necessary if wash water were reused as brine. These water quality results, in conjunction with copper chemical equilibrium modeling, show pH and dissolved carbon both significantly impact the total dissolved copper concentration and should be measured to assess reuse potential. The sampling protocol and specific obstacles highlighted in this paper aid in the future development of sustainable wash water management strategies.

  12. Exploratory Disposal and Reuse Feasibility Analysis of Winter Maintenance Wash Water.

    Directory of Open Access Journals (Sweden)

    Heather L Ullinger

    Full Text Available The Ohio Department of Transportation has more than 60 facilities without sewer access generating approximately 19 million gallons of winter maintenance wash water. Off-site disposal is costly, creating the need for sustainable management strategies. The objective of this study was to conduct an exploratory feasibility analysis to assess wash water disposal and potential reuse as brine. Based on a comprehensive literature review and relevant environmental chemistry, a sampling protocol consisting of 31 water quality constituents was utilized for monthly sampling at three geographically distinct Ohio Department of Transportation garages during the winter of 2012. Results were compared to local disposal and reuse guidance limits. Three constituents, including a maximum copper concentration of 858 ppb, exceeded disposal limits, and many constituents also failed to meet reuse limits. Some concentrations were orders of magnitude higher than reuse limits and suggest pre-treatment would be necessary if wash water were reused as brine. These water quality results, in conjunction with copper chemical equilibrium modeling, show pH and dissolved carbon both significantly impact the total dissolved copper concentration and should be measured to assess reuse potential. The sampling protocol and specific obstacles highlighted in this paper aid in the future development of sustainable wash water management strategies.

  13. 33 CFR 157.150 - Crude Oil Washing Operations and Equipment Manual: Recording information after inspections.

    Science.gov (United States)

    2010-07-01

    ... Equipment Manual: Recording information after inspections. 157.150 Section 157.150 Navigation and Navigable... Vessels Inspections § 157.150 Crude Oil Washing Operations and Equipment Manual: Recording information... machines. (2) Revolutions, number of cycles, and length of cycles of each COW machine. (3) Pressure and...

  14. Estimated ground-water recharge from streamflow in Fortymile Wash near Yucca Mountain, Nevada

    Energy Technology Data Exchange (ETDEWEB)

    Savard, C.S.

    1998-10-01

    The two purposes of this report are to qualitatively document ground-water recharge from stream-flow in Fortymile Wash during the period 1969--95 from previously unpublished ground-water levels in boreholes in Fortymile Canyon during 1982--91 and 1995, and to quantitatively estimate the long-term ground-water recharge rate from streamflow in Fortymile Wash for four reaches of Fortymile Wash (Fortymile Canyon, upper Jackass Flats, lower Jackass Flats, and Amargosa Desert). The long-term groundwater recharge rate was estimated from estimates of the volume of water available for infiltration, the volume of infiltration losses from streamflow, the ground-water recharge volume from infiltration losses, and an analysis of the different periods of data availability. The volume of water available for infiltration and ground-water recharge in the four reaches was estimated from known streamflow in ephemeral Fortymile Wash, which was measured at several gaging station locations. The volume of infiltration losses from streamflow for the four reaches was estimated from a streamflow volume loss factor applied to the estimated streamflows. the ground-water recharge volume was estimated from a linear relation between infiltration loss volume and ground-water recharge volume for each of the four reaches. Ground-water recharge rates were estimated for three different periods of data availability (1969--95, 1983--95, and 1992--95) and a long-term ground-water recharge rate estimated for each of the four reaches.

  15. Clay-oil flocculation during surf washing at the Sea Empress incident

    International Nuclear Information System (INIS)

    Wood, P.; Lunel, T.; Bailey, N.; Lee, K.

    1997-01-01

    Results of investigations into clay-oil flocculation during surf washing of oiled cobbles at Marros Beach, as a response to oiling during the Sea Empress incident, were summarized. Stranded oil on the cobble storm beach was found to associate with fine minerals and form flocs when introduced into sea water. The emulsions persisted for about 14 days after the oiling, after which it begun to disintegrate. After 50 days the remaining emulsion was found to be unstable and penetrated the beach to depths of up to three meters. Since no evidence of biodegradation was found during this period, oil reduction was attributed to sheening, facilitated by tidal fluctuations. Surf washing operation was undertaken over a seven day period beginning 47 days after the spill. Some 8150 tonnes of oiled cobbles were moved a distance of between 12 and 18 m seaward along a length of 850 m. Analysis of samples after two days following surf washing showed that oil concentration did not exceed 22 ppm, compared to 700 ppm before relocation. The significant reduction was considered to have been the result of enhanced oil dispersion coupled with the effects of the surf washing operations. 10 refs., 7 tabs., 10 figs

  16. Removal of oxyfluorfen from ex-situ soil washing fluids using electrolysis with diamond anodes.

    Science.gov (United States)

    dos Santos, Elisama Vieira; Sáez, Cristina; Martínez-Huitle, Carlos Alberto; Cañizares, Pablo; Rodrigo, Manuel Andres

    2016-04-15

    In this research, firstly, the treatment of soil spiked with oxyfluorfen was studied using a surfactant-aided soil-washing (SASW) process. After that, the electrochemical treatment of the washing liquid using boron doped diamond (BDD) anodes was performed. Results clearly demonstrate that SASW is a very efficient approach in the treatment of soil, removing the pesticide completely by using dosages below 5 g of sodium dodecyl sulfate (SDS) per Kg of soil. After that, complete mineralization of organic matter (oxyflourfen, SDS and by-products) was attained (100% of total organic carbon and chemical oxygen demand removals) when the washing liquids were electrolyzed using BDD anodes, but the removal rate depends on the size of the particles in solution. Electrolysis of soil washing fluids occurs via the reduction in size of micelles until their complete depletion. Lower concentrations of intermediates are produced (sulfate, chlorine, 4-(trifluoromethyl)-phenol and ortho-nitrophenol) during BDD-electrolyzes. Finally, it is important to indicate that, sulfate (coming from SDS) and chlorine (coming from oxyfluorfen) ions play an important role during the electrochemical organic matter removal. Copyright © 2016 Elsevier Ltd. All rights reserved.

  17. Weed seed spread and its prevention: The role of roadside wash down.

    Science.gov (United States)

    Bajwa, Ali Ahsan; Nguyen, Thi; Navie, Sheldon; O'Donnell, Chris; Adkins, Steve

    2018-02-15

    Vehicles are one of the major vectors of long-distance weed seed spread. Viable seed removed from vehicles at roadside wash down facilities was studied at five locations in central Queensland, Australia over a 3-year period. Seed from 145 plant species, belonging to 34 different families, were identified in the sludge samples obtained from the wet particulate matter collection pit of the wash down facilities. Most of the species were annual forbs (50%) with small or very small seed size (weed was observed in these samples. More parthenium weed seed were found in the Rolleston facility and in the spring, but its seed was present in all facilities and in all seasons. The average number of viable seed found within every ton of dry particulate matter removed from vehicles was ca. 68,000. Thus, a typical wash down facility was removing up to ca. 335,000 viable seed from vehicles per week, of which ca. 6700 were parthenium weed seed. Furthermore, 61% of these seed (ca. 200,000) were from introduced species, and about half of these (35% of total) were from species considered to be weeds. Therefore, the roadside wash down facilities found throughout Queensland can remove a substantial amount of viable weed seed from vehicles, including the invasive parthenium weed, and the use of such facilities should be strongly encouraged. Copyright © 2017 Elsevier Ltd. All rights reserved.

  18. Effect of washing on the plasma membrane and on stress reactions of cultured rose cells

    International Nuclear Information System (INIS)

    Qian, Y.C.; Nguyen, T.; Murphy, T.M.

    1993-01-01

    Cultured cells of Rosa damascena have been used as a model for studies of responses of plant cells to various stresses, including UV radiation, protein-synthesis inhibitors, and elicitors from pathogens. Many of the responses involve reactions at the plasma membrane: efflux of K + , changes in the acid balance between cytoplasm and external medium, synthesis of H 2 O 2 , and inhibition of ferricyanide reduction. In previous studies, the cells have typically been washed with a solution of low ionic strength. We now show that this washing procedure results in changes in the protein composition of the plasma membrane, in the labeling of the proteins in the plasma membrane, and in the specific activity of ATPase in purified plasma membrane vesicles. Also, compared to the unwashed cells, the washed cells show less net K + efflux after UV-C and Phytophthora elicitor treatments; more synthesis of H 2 O 2 after UV-C and a pattern of accumulation of H 2 O 2 after elicitor treatment that shows a delayed but higher peak; and more inhibition of ferricyanide reduction after UV-C, but not after elicitor treatment. The results suggest that washing has differential effects on the mechanisms by which cultured plant cells perceive or respond to two stresses, UV-C and elicitor

  19. 78 FR 28577 - Notification of Proposed Production Activity: Whirlpool Corporation Subzone 8I; (Washing Machines...

    Science.gov (United States)

    2013-05-15

    ... machine parts to the list of approved finished products and would also add imported components to the...; refrigeration parts; dishwashing machine parts; drying machine parts; water inlet valves; AC/DC fan motors; AC... Activity: Whirlpool Corporation Subzone 8I; (Washing Machines): Clyde and Green Springs, Ohio Whirlpool...

  20. "Wash leather scrotum" (scrotal dermatitis): a treatable cause of male infertility.

    Science.gov (United States)

    Hendry, W F; Munro, D D

    1990-02-01

    A group of 16 male patients with infertility had dermatitis of the scrotum and groins giving lichenified oedematous skin; the resulting thickening and loss of rugosity produced a characteristic appearance that we have termed wash leather scrotum. Treatment of the dermatosis resulted in an improvement in sperm count and motility in most patients, and 5 couples produced one or more pregnancies.

  1. Fenton oxidation treatment of spent wash-off liquor for reuse in reactive dying

    International Nuclear Information System (INIS)

    Mangat, A.; Shaikh, I.A.; Ahmed, F.; Baqar, M

    2014-01-01

    The use of clean and high quality water in textile dyeing process is very expensive. In this study, the potential of reusing Fenton treated wash-off wastewater generated at the end of reactive dyeing was investigated. The treated wastewater was used in several dyeings employing three widely used reactive dyes, C. I. Reactive Yellow 145, C. I. Reactive Red 194, and C. I. Reactive Blue 221. Experimental results showed that at acidic pH (3.5) using optimized quantities of FeSO/sub 4/ and H/sub 2/O/sub 2/, Fenton process yielded a significant reduction (80-99%) of colour and COD in 30 minutes of treatment time. New dyeings were then carried out in Fenton decolourized wash-off wastewater, and dyed fabric samples were subjected to quality evaluations in terms of wash fastness, crock fastness, and colour difference properties (delta L*, delta c*, delta h*, and delta E*). This study concluded that Fenton oxidation was an efficient method for the treatment of textile wash-off wastewater, and treated liquor can be effectively recycled in next dyeing, without compromising quality parameters. This method proved to be an eco-friendly process owing to the fact that it did not use any fresh water. (author)

  2. Trace elements retained in washed nuclear fuel reprocessing solvents

    International Nuclear Information System (INIS)

    Gray, L.W.; MacMurdo, K.W.

    1979-09-01

    Analysis of purified TBP extractant from solvent extraction processes at Savannah River Plant showed several stable elements and several long-lived radioisotopes. Stable elements Al, Na, Br, Ce, Hg, and Sm are found in trace quantities in the solvent. The only stable metallic element consistently found in the solvent was Al, with a concentration which varies from about 30 ppM to about 10 ppM. The halogens Br and Cl appear to be found in the solvent systems as organo halides. Radionuclides found were principally 106 Ru, 129 I, 3 H, 235 U, and 239 Pu. The 129 I concentration was about 1 ppM in the first solvent extraction cycle of each facility. In the other cycles, 129 I concentration varied from about 0.1 to 0.5 ppM. Both 129 I and 3 H appear to be in the organic solvent as a result of exchange with hydrogen

  3. Recycling of Pre-Washed Municipal Solid Waste Incinerator Fly Ash in the Manufacturing of Low Temperature Setting Geopolymer Materials

    Directory of Open Access Journals (Sweden)

    Raffaele Cioffi

    2013-08-01

    Full Text Available In this work, three samples of municipal solid waste incinerators fly ash (MSWI-FA have been stabilized in systems containing coal fly ash to create geopolymers through a polycondensation reaction. Monolithic products have been obtained with both MSWI fly ash as received and after the partial removal of chloride and sulfate by water washing. The polycondensation products have been characterized qualitatively by means of Fourier transform infrared spectroscopy, X-ray diffraction and scanning electron microscopy and quantitatively, through the determination of the volume of reacted water and silicate. Furthermore, the heavy metals and chloride releases together with the physico-mechanical properties have been evaluated on the hardened products. In conclusion, considering the technological and environmental performances of the obtained geopolymers, they could be suitable for many non-structural applications, such as backfilling of abandoned quarries, decorative materials or brick fireplaces, hearths, patios, etc.

  4. Recycling of Pre-Washed Municipal Solid Waste Incinerator Fly Ash in the Manufacturing of Low Temperature Setting Geopolymer Materials.

    Science.gov (United States)

    Ferone, Claudio; Colangelo, Francesco; Messina, Francesco; Santoro, Luciano; Cioffi, Raffaele

    2013-08-12

    In this work, three samples of municipal solid waste incinerators fly ash (MSWI-FA) have been stabilized in systems containing coal fly ash to create geopolymers through a polycondensation reaction. Monolithic products have been obtained with both MSWI fly ash as received and after the partial removal of chloride and sulfate by water washing. The polycondensation products have been characterized qualitatively by means of Fourier transform infrared spectroscopy, X-ray diffraction and scanning electron microscopy and quantitatively, through the determination of the volume of reacted water and silicate. Furthermore, the heavy metals and chloride releases together with the physico-mechanical properties have been evaluated on the hardened products. In conclusion, considering the technological and environmental performances of the obtained geopolymers, they could be suitable for many non-structural applications, such as backfilling of abandoned quarries, decorative materials or brick fireplaces, hearths, patios, etc.

  5. Linde Rectiscol{reg_sign} process. The most economic and experienced wash process for removal of sulfur compounds and CO{sub 2} from gasification gases

    Energy Technology Data Exchange (ETDEWEB)

    Kaballo, H.-P.; Kerestceciogly, U. [Linde AG, Hoellriegelskreuth (Germany). Linde Engineering Division

    2006-07-01

    The Recitsol{reg_sign} wash process is a well-proven process for the removal of H{sub 2}S/COS and CO{sub 2} from coal, asphalt, pitch or oil derived synthesis gas. It is a physical gas wash system using methanol as solvent at operating temperatures below water freezing point, to produce a synthesis gas with less than 0.1 vppm of total sulfur. The CO{sub 2} content can be adjusted in a range from several mol-percent down to a few ppm, as is required by the specified application. Its main advantages are the use of cheap and readily available methanol as solvent, the very flexible process configuration, and rather low utility consumption figures compared with other wash processes, like PEGE based process or chemical washes. A modern concept of a Rectisol{reg_sign} unit is described, to treat shifted and un-shifted gases in just one plant: shifted gas was used for hydrotreating in a refinery. Unshifted gas was used as fuel gas for power generation in an IGCC. CO{sub 2} of the unshifted feed gas was removed only partly, because the remaining CO{sub 2} was fed as inert gas together with the fuel gas to an IGCC. All sulfur compounds of both feed gases were concentrated in one single stream with a high H{sub 2}S concentration. Impurities like NH{sub 3}, HCN or metal carbonyls were eliminated nearly quantitatively. 4 refs., 4 figs., 3 tabs.

  6. Roles of EDTA washing and Ca{sup 2+} regulation on the restoration of anammox granules inhibited by copper(II)

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Zheng-Zhe; Cheng, Ya-Fei; Zhou, Yu-Huang; Buayi, Xiemuguli [Department of Environmental Science and Engineering, Hangzhou Normal University, Hangzhou 310036 (China); Key Laboratory of Hangzhou City for Ecosystem Protection and Restoration, Hangzhou Normal University, Hangzhou 310036 (China); Jin, Ren-Cun, E-mail: jrczju@aliyun.com [Department of Environmental Science and Engineering, Hangzhou Normal University, Hangzhou 310036 (China); Key Laboratory of Hangzhou City for Ecosystem Protection and Restoration, Hangzhou Normal University, Hangzhou 310036 (China)

    2016-01-15

    Highlights: • 80.5% of the Cu in anammox granules was introduced via adsorption. • Cu(II) internalized on/into AnAOB cells plays a crucial role in toxicity. • EDTA washing contributes to the detoxification of anammox granules. • Ca{sup 2+} can stimulate the re-growth of damaged anammox consortium. - Abstract: We investigated the feasibility of using ethylene diamine tetraacetic acid (EDTA) washing followed by Ca{sup 2+} enhancement for the recovery of anammox reactors inhibited by Cu(II). Kinetic experiments and batch activity assays were employed to determine the optimal concentration of EDTA and washing time; and the performance and physiological dynamics were tracked by continuous-flow monitoring to evaluate the long-term effects. The two-step desorption process revealed that the Cu in anammox granules was primarily introduced via adsorption (approximately, 80.5%), and the portion of Cu in the dispersible layer was predominant (accounting for 71.1%). Afterwards, the Cu internalized in the cells (approximately, 14.7%) could diffuse out of the cells and be gradually washed out of the reactor over the next 20 days. The Ca{sup 2+} addition that followed led to an accelerated nitrogen removal rate recovery slope (0.1491 kgN m{sup −3} d{sup −2}) and a normal biomass growth rate (0.054 d{sup −1}). The nitrogen removal rate returned to normal levels within 90 days and gradual improvements in granular characteristics were also achieved. Therefore, this study provides a new insight that externally removing the adsorbed heavy metals followed by internally repairing the metabolic system may represent an optimal restoration strategy for anammox consortium damaged by heavy metals.

  7. Washing ashore: The politics of offshore oil in northern Angola

    Science.gov (United States)

    Reed, Kristin Michelle

    This dissertation examines the political ecology of Angolan oil, by exploring state and corporate political economies; historical convergences of violence and capital; and struggles over the costs and benefits of oil production from the perspective of artisanal fishing and farming communities in the extractive zones. Angola is sub-Saharan Africa's second-largest oil producer but revenues from the enclave sector in oil rarely trickle down to the impoverished populace. The Angolan government strategically invests petrodollars in patronage networks to bolster their power; and watchdog agencies claim top officials divert the balance to offshore accounts. While the enclaved nature of production facilitates the restricted distribution of oil monies by concentrating services and revenue streams, the distortions and externalities that bleed out from these enclaves increase the misery of Angolans---especially those living in the extractive zones. By focusing on the lived experience of extraction, I explore the politics of oil through the forms of violence and degradation threatening the lives and livelihoods of local people. Most of Angola's oil is produced from offshore fields, so oil spills present a considerable risk to the health of local communities and ecosystems. The fishers and fish traders suffering from oil spills demand compensation from the liable oil corporations, yet the skewed system of disbursements only reaches the most powerful claimants. Moreover, faced with a repressive and unresponsive government, communities in extractive zones have come to rely on the same corporations for schools and health posts in a system I refer to as oil-backed development. I demonstrate that local histories of violence, national political exigencies, and transnational corporate interests govern the distribution of oil-backed development projects. Furthermore, I argue that the Angolan government leverages corporate donations for development to suit its own exclusionary interests

  8. Salmonella transfer during pilot plant scale washing and roller conveying of tomatoes.

    Science.gov (United States)

    Wang, Haiqiang; Ryser, Elliot T

    2014-03-01

    Salmonella transfer during washing and roller conveying of inoculated tomatoes was quantified using a pilot scale tomato packing line equipped with plastic, foam, or brush rollers. Red round tomatoes (2.3 kg) were dip inoculated with Salmonella enterica serovar Typhimurium LT2 (avirulent) (4 log CFU/g), air dried for 2 h, and then washed in sanitizer-free water for 2 min. Inoculated tomatoes were then passed single file over a 1.5-m conveyor equipped with plastic, foam, or brush rollers followed by 25 previously washed uninoculated tomatoes. Tomato samples were collected after 2 min of both washing and roller conveying, with all 25 uninoculated tomatoes collected individually after conveying. Roller surface samples were collected before and after conveying the uninoculated tomatoes. Both tomato and surface samples were quantitatively examined for Salmonella by direct plating or membrane filtration using xylose lysine Tergitol 4 agar. Regardless of the roller type, Salmonella populations on inoculated tomatoes did not significantly (P conveyors. After conveying uninoculated tomatoes over contaminated foam rollers, 96% of the 25 tomatoes were cross-contaminated with Salmonella at >100 CFU per tomato. With plastic rollers, 24 and 76% of tomatoes were cross-contaminated with Salmonella at 10 to 100 and 1 to 10 CFU per tomato, respectively. In contrast, only 8% of 25 tomatoes were cross-contaminated with brush rollers with Salmonella populations of 1 to 10 CFU per tomato. Overall, cross-contamination was greatest with foam, followed by plastic and brush rollers (P < 0.05). Adding peroxyacetic acid or chlorine to the wash water significantly decreased cross-contamination during tomato conveying, with chlorine less effective in controlling Salmonella on foam compared with plastic and brush rollers.

  9. Soil remediation: humic acids as natural surfactants in the washings of highly contaminated soils

    International Nuclear Information System (INIS)

    Conte, Pellegrino; Agretto, Anna; Spaccini, Riccardo; Piccolo, Alessandro

    2005-01-01

    The remediation of the highly contaminated site around the former chemical plant of ACNA (near Savona) in Northern Italy is a top priority in Italy. The aim of the present work was to contribute in finding innovative and environmental-friendly technology to remediate soils from the ACNA contaminated site. Two soils sampled from the ACNA site (A and B), differing in texture and amount and type of organic contaminants, were subjected to soil washings by comparing the removal efficiency of water, two synthetic surfactants, sodium dodecylsulphate (SDS) and Triton X-100 (TX100), and a solution of a natural surfactant, a humic acid (HA) at its critical micelle concentration (CMC). The extraction of pollutants by sonication and soxhlet was conducted before and after the soil washings. Soil A was richer in polycyclic aromatic hydrocarbons, whereas soil B had a larger content of thiophenes. Sonication resulted more analytically efficient in the fine-textured soil B. The coarse-textured soil A was extracted with a general equal efficiency also by soxhlet. Clean-up by water was unable to exhaustively remove contaminants from the two soils, whereas all the organic surfactants revealed very similar efficiencies (up to 90%) in the removal of the contaminants from the soils. Hence, the use of solutions of natural HAs appears as a better choice for soil washings of highly polluted soils due to their additional capacity to promote microbial activity, in contrast to synthetic surfactants, for a further natural attenuation in washed soils. - Solutions of natural humic acids appear to be a better choice for washing highly polluted soils

  10. Proven and potential clinical benefits of washing red blood cells before transfusion: current perspectives

    Directory of Open Access Journals (Sweden)

    Schmidt AE

    2016-08-01

    Full Text Available Amy E Schmidt, Majed A Refaai, Scott A Kirkley, Neil Blumberg Department of Pathology and Laboratory Medicine, University of Rochester Medical Center, Rochester, NY, USA Abstract: Red blood cells (RBCs are washed for a variety of reasons such as to remove excess potassium, cytokines, and other allergen proteins from the supernatant and/or to mitigate the effects of the storage lesion. The storage lesion is a product of RBC aging and include leakage of potassium and chloride from the RBCs, depletion of 2,3-diphosphoglycerate and adenosine triphosphate, loss of phospholipids and cholesterol, exposure of phosphatidylserine, elaboration of lipid mediators, loss of glutathione, autoxidation of hemoglobin to methemoglobin contributing to decreased blood flow viscosity and adherence to endothelial cells, increased microparticle formation, and disruption of NO-mediated vasodilation. A storage lesion is thought to be caused in part by oxidative stress, which is characterized by functional and structural changes to the RBCs. The effects of the RBC storage lesion on patient morbidity and mortality have been studied intensively with mixed results. Here, we will summarize the potential benefits of RBC washing. Notably, all patient-based studies on washed RBCs are single-center, small randomized studies or observational data, which await replication and tests of generalizability. Some of the most promising preliminary data suggest that washed transfusions of red cells and platelets reduce mortality in low risk, younger patients with acute myeloid leukemia, mitigate lung injury, and substantially reduce mortality in cardiac surgery. Larger randomized trials to replicate or refute these findings are urgently needed and, most importantly, have the potential to strikingly improve clinical outcomes following transfusion. Keywords: washed blood, transfusion, immunomodulation, red blood cell

  11. Effect of exhaust emissions on carbon monoxide levels in employees working at indoor car wash facilities.

    Science.gov (United States)

    Topacoglu, H; Katsakoglou, S; Ipekci, A

    2014-01-01

    Exhaust emissions from motor vehicles threaten the environment and human health. Carbon monoxide (CO) poisoning, especially the use of exhaust gas CO in suicidal attempts is well known in the literature. Recently, indoor car wash facilities established in large shopping malls with closed parking, lots is a new risk area that exposes car wash employees to prolonged periods of high level CO emissions from cars. The aim of this study was to investigate how carboxyhemoglobin (COHb) blood levels of employees get affected in confined areas with relatively poor air circulation. Twenty male volunteers working in indoor parking car wash facilities were included in the study. Participants were informed about the aim of this study and their consent was obtained. Their pulse COHb levels were measured twice, at the beginning and at the end of the working day using Rad-57 pulse CO-oximeter device, allowing non-invasive measurement of COHb blood levels to compare the changes in their COHb levels before and after work. The mean age of the male volunteers was 29.8 ± 11.9 (range 18-55). While the mean COHb levels measured at the start of the working day was 2.1 ± 2.0 (range 0-9), it was increased to 5.2 ± 3.3 (range 1-15) at the end of work shift (Wilcoxon test, p car wash facility employees is directly impacted and gets elevated by motor vechile exhaust emissions. For the health of the employees at indoor parking car wash facilities, stricter precautions are needed and the government should not give permit to such operations.

  12. [Customization of hemodialysis therapy: dialysis is not a washing machine].

    Science.gov (United States)

    Santoro, Antonio

    2018-02-01

    In recent years, the population of chronic dialysis has grown in number but also in age and frequency of co-morbidies such as cardiac diseases, vascular pathologies, diabetes, etc. The majority of patients on chronic hemodialysis are over 70 years and, given the high number of comorbidities, they often exhibit poor tolerance to dialysis treatments. A non-tolerated dialytic treatment can have side-effects that would require an intensification of the dialysis sessions and many hospitalizations. Consequently, the problematic dialysis treatments, as well as harmful for the patient, become economically more detrimental than other treatments apparently more expensive but more tolerated ones In the current days we have, thanks to the huge developments in dialysis technology, powerful weapons to ensure effective and scarcely symptomatic dialysis treatments to the majority of the HD patients. New, highly biocompatible membranes with defined and modular cut-off and / or absorption capacity may allow us to provide adequate purification. Moreover the monitoring and biofeedback systems such as blood volume tracking, body temperature monitoring (BTM) and blood pressure (BPM) can be very useful in reducing the risk of intra-dialytic hypotension and symptoms. Therefore, the dialytic therapy, as well as all the pharmacological therapies for the chronic patient, must consider the specificity of the patient, basing on his metabolic problems, cardiovascular tolerance, residual renal function and on his dietary and general compliance. The central aim of the nephrologist is to formulate the better prescription for the individual patient, considering the dialysis modalities, the membrane type, the dry weight (ideal post-dialysis body weight), the frequency and the duration of the weekly sessions and the technological tools that can optimize the treatment. Copyright by Società Italiana di Nefrologia SIN, Rome, Italy.

  13. Proper Hand-Washing Techniques in Public Restrooms: Differences in Gender, Race, Signage, and Time of Day

    Science.gov (United States)

    Kinnison, Andrea; Cottrell, Randal R.; King, Keith A.

    2004-01-01

    The purpose of this study was to evaluate hand washing behaviors in public restrooms with and without reminder signs. Gender, race, signage, and time of day were examined to determine if there were differences in hand washing compliance based on these variables. Participants included male and female adults entering restrooms at two public shopping…

  14. Comparison of methanol and isopropanol as wash solvents for determination of hair cortisol concentration in grizzly bears and polar bears.

    Science.gov (United States)

    Kroshko, Thomas; Kapronczai, Luciene; Cattet, Marc R L; Macbeth, Bryan J; Stenhouse, Gordon B; Obbard, Martyn E; Janz, David M

    2017-01-01

    Methodological differences among laboratories are recognized as significant sources of variation in quantification of hair cortisol concentration (HCC). An important step in processing hair, particularly when collected from wildlife, is the choice of solvent used to remove or "wash" external hair shaft cortisol prior to quantification of HCC. The present study systematically compared methanol and isopropanol as wash solvents for their efficiency at removing external cortisol without extracting internal hair shaft cortisol in samples collected from free-ranging grizzly bears and polar bears. Cortisol concentrations in solvents and hair were determined in each of one to eight washes of hair with each solvent independently. •There were no significant decreases in internal hair shaft cortisol among all eight washes for either solvent, although methanol removed detectable hair surface cortisol after one wash in grizzly bear hair whereas hair surface cortisol was detected in all eight isopropanol washes.•There were no significant differences in polar bear HCC washed one to eight times with either solvent, but grizzly bear HCC was significantly greater in hair washed with isopropanol compared to methanol.•There were significant differences in HCC quantified using different commercial ELISA kits commonly used for HCC determinations.

  15. Effects of household washing on bacterial load and removal of Escherichia coli from lettuce and "ready-to-eat" salads.

    Science.gov (United States)

    Uhlig, Elisabeth; Olsson, Crister; He, Jiayi; Stark, Therese; Sadowska, Zuzanna; Molin, Göran; Ahrné, Siv; Alsanius, Beatrix; Håkansson, Åsa

    2017-11-01

    Customer demands for fresh salads are increasing, but leafy green vegetables have also been linked to food-borne illness due to pathogens such as Escherichia coli O157:H7. As a safety measure, consumers often wash leafy vegetables in water before consumption. In this study, we analyzed the efficiency of household washing to reduce the bacterial content. Romaine lettuce and ready-to-eat mixed salad were washed several times in flowing water at different rates and by immersing the leaves in water. Lettuce was also inoculated with E. coli before washing. Only washing in a high flow rate (8 L/min) resulted in statistically significant reductions ( p  < .05), "Total aerobic count" was reduced by 80%, and Enterobacteriaceae count was reduced by 68% after the first rinse. The number of contaminating E. coli was not significantly reduced. The dominating part of the culturable microbiota of the washed lettuce was identified by rRNA 16S sequencing of randomly picked colonies. The majority belonged to Pseudomonadaceae , but isolates from Enterobacteriaceae and Staphylococcaceaceae were also frequently found. This study shows the inefficiency of tap water washing methods available for the consumer when it comes to removal of bacteria from lettuce. Even after washing, the lettuce contained high levels of bacteria that in a high dose and under certain circumstances may constitute a health risk.

  16. 75 FR 25876 - Notice of Intent To Prepare Resource Management Plans for the Beaver Dam Wash and Red Cliffs...

    Science.gov (United States)

    2010-05-10

    ... Intent To Prepare Resource Management Plans for the Beaver Dam Wash and Red Cliffs National Conservation... Environmental Impact Statement, Utah AGENCY: Bureau of Land Management, Interior. ACTION: Notice of intent..., intends to prepare Resource Management Plans (RMP) for the Beaver Dam Wash and the Red Cliffs National...

  17. The application of membrane technology for reuse of process water and minimisation of waste water in a textile washing range

    NARCIS (Netherlands)

    van t Hul, J.P.; Racz, I.G.; Reith, T.

    1997-01-01

    Recycling of process streams and reduction of waste disposal using membrane technology in a continuous textile washing process after dyeing with reactive dyes have been investigated theoretically. A mathematical process model of a conventional open-width washing range has been extended by membrane

  18. 21 CFR 173.315 - Chemicals used in washing or to assist in the peeling of fruits and vegetables.

    Science.gov (United States)

    2010-04-01

    ... peeling of fruits and vegetables. 173.315 Section 173.315 Food and Drugs FOOD AND DRUG ADMINISTRATION... used in washing or to assist in the peeling of fruits and vegetables. Chemicals may be safely used to wash or to assist in the peeling of fruits and vegetables in accordance with the following conditions...

  19. Effects of particle size on the morphology and waterand thermo-resistance of washed cottonseed meal-based wood adhesives

    Science.gov (United States)

    Water wash of cottonseed meal is more cost-efficient and environment-friendly than the protein isolation which involves alkaline extraction and acidic precipitation. Thus, water-washed cottonseed meal (WCSM) is more promising as biobased wood adhesives. In this work, we examined the effects of the p...

  20. The sequential use of washing and an electrochemical reduction process for the remediation of lead-contaminated soils.

    Science.gov (United States)

    Demir, Aydeniz; Köleli, Nurcan

    2013-01-01

    A two-step method for the remediation of three different types of lead (Pb)-contaminated soil was evaluated. The first step included soil washing with ethylenediaminetetraacetic acid (EDTA) to remove Pb from soils. The washing experiments were performed with 0.05 M Na2EDTA at 1:10 soil to liquid ratio. Following the washing, Pb removal efficiency from soils ranged within 50-70%. After the soil washing process, Pb2+ ions in the washing solution were reduced electrochemically in a fixed-bed reactor. Lead removal efficiency with the electrochemical reduction at -2.0 V potential ranged within 57-76%. The overall results indicate that this two-step method is an environmentally-friendly and effective technology to remediate Pb-contaminated soils, as well as Pb-contaminated wastewater treatment due to the transformation of toxic Pb2+ ions into a non-hazardous metallic form (Pb(0)).

  1. Cross-flow filtration during the washing of a simulated radioactive waste stream

    International Nuclear Information System (INIS)

    MARK R., DUIGNAN

    2005-01-01

    Bechtel National, Inc. has been contracted by the Department of Energy to design a Waste Treatment and Immobilization Plant (WTP) to stabilize liquid radioactive waste that is stored at the Hanford Site as part of the River Protection Project (RPP). Because of its experience with radioactive waste stabilization, the Savannah River National Laboratory (SRNL) of the Westinghouse Savannah River Company is working with Bechtel and Washington Group International, to help design and test certain parts of the waste treatment facility. One part of the process is the separation of radioactive solids from the liquid wastes by cross-flow ultrafiltration. To test this process a cross-flow filter was used that was prototypic in porosity, length, and diameter, along with a simulated radioactive waste slurry, made to prototypically represent the chemical and physical characteristics of a Hanford waste in tank 241-AY-102/C-106. To mimic the filtration process the waste slurry undergoes several steps, including dewatering and washing. During dewatering the concentration of undissolved solids (UDS) of the simulated AY102/C106 waste is increased from 12 wt percent to at least 20 wt percent. Once at the higher concentration the waste must be washed to prepare for its eventual receipt in a High Level Radioactive Waste Melter to be vitrified. This paper describes the process of washing and filtering a batch of concentrated simulated waste in two cycles, which each containing 22 washing steps that used approximately 7.7 liters of a solution of 0.01 M NaOH per step. This will be the method used by the full-scale WTP to prepare the waste for vitrification. The first washing cycle started with the simulated waste that had a solids concentration of 20 wt percent UDS. This cycle began with a permeate filter flux of 0.015 gpm/ft2 (3.68 cm/hr) at 19.6 wt percent UDS with a density of 1.33 kg/L, and yield stress of 8.5 Pa. At the end of the 22 washing steps the permeate filter flux increased to

  2. Regular use of a hand cream can attenuate skin dryness and roughness caused by frequent hand washing

    Directory of Open Access Journals (Sweden)

    Kampf Günter

    2006-02-01

    Full Text Available Abstract Background Aim of the study was to determine the effect of the regular use of a hand cream after washing hands on skin hydration and skin roughness. Methods Twenty-five subjects washed hands and forearms with a neutral soap four times per day, for 2 minutes each time, for a total of two weeks. One part of them used a hand cream after each hand wash, the others did not (cross over design after a wash out period of two weeks. Skin roughness and skin hydration were determined on the forearms on days 2, 7, 9 and 14. For skin roughness, twelve silicon imprint per subject and time point were taken from the stratum corneum and assessed with a 3D skin analyzer for depth of the skin relief. For skin hydration, five measurements per subject and time point were taken with a corneometer. Results Washing hands lead to a gradual increase of skin roughness from 100 (baseline to a maximum of 108.5 after 9 days. Use of a hand cream after each hand wash entailed a decrease of skin roughness which the lowest means after 2 (94.5 and 14 days (94.8. Skin hydration was gradually decreased after washing hands from 79 (baseline to 65.5 after 14 days. The hand wash, followed by use of a hand cream, still decreased skin hydration after 2 days (76.1. Over the next 12 days, however, skin hydration did not change significantly (75.6 after 14 days. Conclusion Repetitive and frequent hand washing increases skin dryness and roughness. Use of a hand cream immediately after each hand wash can confine both skin dryness and skin roughness. Regular use of skin care preparations should therefore help to prevent both dry and rough skin among healthcare workers in clinical practice.

  3. Stability and Wash Resistance of Local Made Mosquito Bednets and Detergents Treated with Pyrethroids against Anopheles stephensi

    Directory of Open Access Journals (Sweden)

    H Vatandoost

    2009-06-01

    Full Text Available Background: We aimed to evaluate different fibres of bednets impregnated with various pyrethroids. The stability of insecticide on the bednet was measured using different methods of washings as well as local made detergents.Methods: The entire test was carried out according to the WHO-recommended methods. In addition, the impact of the numbers of washes on the stability of the insecticides was determined. Permethrin 10% (EC, deltamethrin 10% (SC, lambdacyhalothrin 2.5% (CS and cyfluthrin 5% (EW were used at the recommended dosages. Three different lo­cal detergents were used. Two kinds of washing methods (shaking, no shaking were used and in each method four kinds of washings, i.e. no wash, one wash, two washes and three washes was done. The main malaria vectors, Anophe­les stephensi, which is susceptible to all insecticides (BEECH strain, was tested with impregnated bednets in 3 minutes exposure time and the mortality was measured after 24 hours recovery period. Knock-down was measured as well using appropriate statistical methods.Results: Lambdacyhalothrin has saved its insecticidal impact after being washed, whereas, deltamethrin has lost its activ­ity faster than other insecticides. Tow other insecticides had moderate effect. Golnar soap detergent has least ef­fect on the durability of insecticides, but the Shoma had the most. Whit increasing  the times of washing, insecticidal ef­fects was decreased , but shaking had no influence on the decreasing  of the quality of insecticidal impact.Conclusion: Results will be useful for local people who wish to use pyrethroid-impregnated bednets with their own lo­cal made detergent and bednets. 

  4. Exploring the gap between hand washing knowledge and practices in Bangladesh: a cross-sectional comparative study.

    Science.gov (United States)

    Rabbi, Sifat E; Dey, Nepal C

    2013-01-30

    Hand washing is considered as one of the most effective hygiene promotion activities for public health in developing countries. This study compared hand washing knowledge and practices in BRAC's water; sanitation and hygiene (WASH) programme areas over time. This study is a cross-sectional comparative study between baseline (2006), midline (2009) and end-line (2011) surveys in 50 sub-districts from the first phase of the programme. Thirty thousand households from 50 sub-districts were selected in two steps: i) 30 villages were selected from each sub-district by cluster sampling, and ii) 20 households were chosen systematically from each village. The matched households were considered (26,404 in each survey) for analysis. Data were collected from households through face-to-face interview using a pre-tested questionnaire. Respondents were the adult female members of the same households, who had knowledge of day-to-day household activities related to water, sanitation and hygiene. A gap between perception and practice of proper hand washing practices with soap was identified in the study areas. Hand washing practice with soap before eating was much lower than after defecation. In baseline data, 8% reported to wash their hands with soap which significantly increased to 22% in end line. Hand washing knowledge and practices before cooking food, before serving food and while handling babies is considerably limited than other critical times. A multivariate analysis shows that socio-economic factors including education of household head and respondent, water availability and access to media have strong positive association with hand washing with soap. Gap between knowledge and practice still persists in hand washing practices. Long term and extensive initiatives can aware people about the effectiveness of hand washing.

  5. Exploring the gap between hand washing knowledge and practices in Bangladesh: a cross-sectional comparative study

    Directory of Open Access Journals (Sweden)

    Rabbi Sifat E

    2013-01-01

    Full Text Available Abstract Background Hand washing is considered as one of the most effective hygiene promotion activities for public health in developing countries. This study compared hand washing knowledge and practices in BRAC’s water; sanitation and hygiene (WASH programme areas over time. Methods This study is a cross-sectional comparative study between baseline (2006, midline (2009 and end-line (2011 surveys in 50 sub-districts from the first phase of the programme. Thirty thousand households from 50 sub-districts were selected in two steps: i 30 villages were selected from each sub-district by cluster sampling, and ii 20 households were chosen systematically from each village. The matched households were considered (26,404 in each survey for analysis. Data were collected from households through face-to-face interview using a pre-tested questionnaire. Respondents were the adult female members of the same households, who had knowledge of day-to-day household activities related to water, sanitation and hygiene. Results A gap between perception and practice of proper hand washing practices with soap was identified in the study areas. Hand washing practice with soap before eating was much lower than after defecation. In baseline data, 8% reported to wash their hands with soap which significantly increased to 22% in end line. Hand washing knowledge and practices before cooking food, before serving food and while handling babies is considerably limited than other critical times. A multivariate analysis shows that socio-economic factors including education of household head and respondent, water availability and access to media have strong positive association with hand washing with soap. Conclusion Gap between knowledge and practice still persists in hand washing practices. Long term and extensive initiatives can aware people about the effectiveness of hand washing.

  6. Time changes in radiocesium wash-off from various land uses after the Fukushima Daiichi NPP accident

    Science.gov (United States)

    Onda, Yuichi; Kato, Hiroaki; Yoshimura, Kazuya; Tsujimura, Maki; Wakiyama, Yoshifumi; Taniguchi, Keisuke; Sakaguchi, Aya; Yamamoto, Masayoshi

    2014-05-01

    A number of studies have been conducted to monitor and model the time series change of radiocesium transfer through aquatic systems after significant fallout, especially from the Chernobyl disaster. However, no data is available for the temporal changes of radiocesium concentration in environmental materials such as soil and water after the Fukushima Daiichi nuclear power plant accident. Our research team has been monitoring the environmental consequences of radioactive contamination just after the Fukushima Daiichi NPP accident in Yamakiya-district, Kawamata town, Fukushima prefecture. Research items are listed below. 1. Radiocesium wash-off from the runoff-erosion plot under different land use. 2. Measurement of radiocesium transfer in forest environment, in association with hydrological pathways such as throughfall and overlandflow on hillslope. 3. Monitoring on radiocesium concentration in soil water, ground water, and spring water. 4. Monitoring of dissolved and particulate radiocesium concentration in river water, and stream water from the forested catchment. 5.Measurement of radiocesium content in drain water and suspended sediment from paddy field. Our monitoring result demonstrated that the Cs-137 concentration in eroded sediment from the runoff-erosion plot has been almost constant for the past 3 years, however the Cs-137 concentration of suspended sediment from the forested catchment showed slight decrease through time. On the other hand, the suspended sediment from paddy field and those in river water from large catchments exhibited rapid decrease in Cs-137 concentration with time. The decreasing trend of Cs-137 concentration were fitted by the two-component exponential model, differences in decreasing rate of the model were compared and discussed among various land uses and catchment scales. Such analysis can provide important insights into the future prediction of the radiocesium wash-off from catchments with different land uses.

  7. Combined effectiveness of anthelmintic chemotherapy and WASH among HIV-infected adults.

    Directory of Open Access Journals (Sweden)

    Arianna R Means

    2018-01-01

    Full Text Available Current global helminth control guidelines focus on regular deworming of targeted populations for morbidity control. However, water, sanitation, and hygiene (WASH interventions may also be important for reducing helminth transmission. We evaluated the impact of different potential helminth protective packages on infection prevalence, including repeated treatment with albendazole and praziquantel with and without WASH access.We conducted a cohort study nested within a randomized trial of empiric deworming of HIV-infected adults in Kenya. Helminth infections and infection intensity were diagnosed using semi-quantitative real-time PCR. We conducted a manual forward stepwise model building approach to identify if there are packages of interventions that may be protective against an STH infection of any species (combined outcome and each helminth species individually. We conducted secondary analyses using the same approach only amongst individuals with no anthelmintis exposure. We used interaction terms to test for potential intervention synergy. Approximately 22% of the 701 stool samples provided were helminth-infected, most of which were of low to moderate intensity. The odds of infection with any STH species were lower for individuals who were treated with albendazole (aOR:0.11, 95%CI: 0.05, 0.20, p<0.001, adjusting for age and sex. Although most WASH conditions demonstrated minimal additional benefit in reducing the probability of infection with any STH species, access to safe flooring did appear to offer some additional protection (aOR:0.34, 95%CI: 0.20, 0.56, p<0.001. For schistosomiasis, only treatment with praziquantel was protective (aOR:0.30 95%CI: 0.14, 0.60, p = 0.001. Amongst individuals who were not treated with albendazole or praziquantel, the most protective intervention package to reduce probability of STH infections included safe flooring (aOR:0.34, 95%CI: 0.20, 0.59, p<0.001 and latrine access (aOR:0.59, 95%CI: 0.35, 0.99, p = 0

  8. Flood potential of Fortymile Wash and its principal southwestern tributaries, Nevada Test Site, Southern Nevada

    International Nuclear Information System (INIS)

    Squires, R.R.; Young, R.L.

    1984-01-01

    Flood hazards for a 9-mile reach of Fortymile Wash and its principal southwestern tributaries - Busted Butte, Drill Hole, and Yucca Washes - were evaluated to aid in determining possible sites for the storage of high-level radioactive wastes on the Nevada Test Site. Data from 12 peak-flow gaging stations adjacent to the Test Site were used to develop regression relations that would permit an estimation of the magnitude of the 100- and 500-year flood peaks (Q 100 and Q 500 ), in cubic feet per second. The resulting equations are: Q 100 = 482A 0 565 and Q 500 = 2200A 0 571 , where A is the tributary drainage area, in square miles. The estimate of the regional maximum flood was based on data from extreme floods elsewhere in Nevada and in surrounding states. Among seven cross sections on Fortymile Wash, the estimated maximum depths of the 100-year, 500-year, and regional maximum floods are 8, 11, and 29 feet, respectively. At these depths, flood water would remain within the deeply incised channel of the wash. Mean flow velocities would be as great as 9, 14, and 28 feet per second for the three respective flood magnitudes. The study shows that Busted Butte and Drill Hole Washes (9 and 11 cross sections, respectively) would have water depths of up to at least 4 feet and mean flow velocities of up to at least 8 feet per second during a 100-year flood. A 500-year flood would exceed stream-channel capacities at several places, with depths to 10 feet and mean flow velocities to 11 feet per second. The regional maximum flood would inundate sizeable areas in central parts of the two watersheds. At Yucca Wash (5 cross sections), the 100-year, 500-year, and regional maximum floods would remain within the stream channel. Maximum flood depths would be about 5, 9, and 23 feet and mean velocities about 9, 12, and 22 feet per second, respectively, for the three floods

  9. Impact of electrochemical treatment of soil washing solution on PAH degradation efficiency and soil respirometry.

    Science.gov (United States)

    Mousset, Emmanuel; Huguenot, David; van Hullebusch, Eric D; Oturan, Nihal; Guibaud, Gilles; Esposito, Giovanni; Oturan, Mehmet A

    2016-04-01

    The remediation of a genuinely PAH-contaminated soil was performed, for the first time, through a new and complete investigation, including PAH extraction followed by advanced oxidation treatment of the washing solution and its recirculation, and an analysis of the impact of the PAH extraction on soil respirometry. The study has been performed on the remediation of genuine PAH-contaminated soil, in the following three steps: (i) PAH extraction with soil washing (SW) techniques, (ii) PAH degradation with an electro-Fenton (EF) process, and (iii) recirculation of the partially oxidized effluent for another SW cycle. The following criteria were monitored during the successive washing cycles: PAH extraction efficiency, PAH oxidation rates and yields, extracting agent recovery, soil microbial activity, and pH of soil. Two representative extracting agents were compared: hydroxypropyl-beta-cyclodextrin (HPCD) and a non-ionic surfactant, Tween(®) 80. Six PAH with different numbers of rings were monitored: acenaphthene (ACE), phenanthrene (PHE), fluoranthene (FLA), pyrene (PYR), benzo(a)pyrene (BaP), and benzo(g,h,i)perylene (BghiP). Tween(®) 80 showed much better PAH extraction efficiency (after several SW cycles) than HPCD, regardless of the number of washing cycles. Based on successive SW experiments, a new mathematical relation taking into account the soil/water partition coefficient (Kd*) was established, and could predict the amount of each PAH extracted by the surfactant with a good correlation with experimental results (R(2) > 0.975). More HPCD was recovered (89%) than Tween(®) 80 (79%), while the monitored pollutants were completely degraded (>99%) after 4 h and 8 h, respectively. Even after being washed with partially oxidized solutions, the Tween(®) 80 solutions extracted significantly more PAH than HPCD and promoted better soil microbial activity, with higher oxygen consumption rates. Moreover, neither the oxidation by-products nor the acidic media (p

  10. Investigation of heterogeneous ice nucleation in pollen suspensions and washing water

    Science.gov (United States)

    Dreischmeier, Katharina; Budke, Carsten; Koop, Thomas

    2014-05-01

    Biological particles such as pollen often show ice nucleation activity at temperatures higher than -20 °C. Immersion freezing experiments of pollen washing water demonstrate comparable ice nucleation behaviour as water containing the whole pollen bodies (Pummer et al., 2012). It was suggested that polysaccharide molecules leached from the grains are responsible for the ice nucleation. Here, heterogeneous ice nucleation in birch pollen suspensions and their washing water was investigated by two different experimental methods. The optical freezing array BINARY (Bielefeld Ice Nucleation ARraY) allows the direct observation of freezing of microliter-sized droplets. The IN spectra obtained from such experiments with birch pollen suspensions over a large concentration range indicate several different ice nucleation active species, two of which are present also in the washing water. The latter was probed also in differential scanning calorimeter (DSC) experiments of emulsified sub-picoliter droplets. Due to the small droplet size in the emulsion samples and at small concentration of IN in the washing water, such DSC experiments can exhibit the ice nucleation behaviour of a single nucleus. The two heterogeneous freezing signals observed in the DSC thermograms can be assigned to two different kinds of ice nuclei, confirming the observation from the BINARY measurements, and also previous studies on Swedish birch pollen washing water (Augustin et al., 2012). The authors gratefully acknowledge funding by the German Research Foundation (DFG) through the project BIOCLOUDS (KO 2944/1-1) and through the research unit INUIT (FOR 1525) under KO 2944/2-1. We particularly thank our INUIT partners for fruitful collaboration and sharing of ideas and IN samples. S. Augustin, H. Wex, D. Niedermeier, B. Pummer, H. Grothe, S. Hartmann, L. Tomsche, T. Clauss, J. Voigtländer, K. Ignatius, and F. Stratmann, Immersion freezing of birch pollen washing water, Atmos. Chem. Phys., 13, 10989

  11. Investigation of Rheological Impacts on Sludge Batch 3 as Insoluble Solids and Wash Endpoints are Adjusted

    International Nuclear Information System (INIS)

    Fellinger, T. L.

    2005-01-01

    The Defense Waste Processing Facility (DWPF) is currently processing and immobilizing radioactive sludge slurry into a durable borosilicate glass. The DWPF has already processed three sludge batches (Sludge Batch 1A, Sludge Batch 1B, and Sludge Batch 2) and is currently processing the fourth sludge batch (Sludge Batch 3). A sludge batch is defined as a single tank of sludge slurry or a combination of sludge slurries from different tanks that has been or will be qualified before being transferred to DWPF. As a part of the Sludge Batch 3 (SB3) qualification task, rheology measurements of the sludge slurry were requested at different insoluble solids loadings. These measurements were requested in order to gain insight into potential processing problems that may occur as the insoluble solids are adjusted up or down (by concentration or dilution) during the process. As a part of this study, a portion of the ''as received'' SB3 sample was washed with inhibited water (0.015 M NaOH and 0.015 M NaNO2) to target 0.5M Na versus a measured 1M Na in the supernate. The purpose of the ''washing'' step was to allow a comparison of the SB3 rheological data to the rheological data collected for Sludge Batch 2 (SB2) and to determine if there was a dependence of the yield stress and consistency as a function of washing. The ''as received'' SB3 rheology data was also compared to SB3 simulants prepared by the Simulant Development Program in order to provide guidance for selecting a simulant that is more representative of the rheological properties of the radioactive sludge slurry. A summary of the observations, conclusions are: (1) The yield stress and plastic viscosity increased as the weight percent insoluble solids were increased for the ''as received'' and ''washed'' SB3 samples, at a fixed pH. (2) For the same insoluble solids loading, the yield stress for the SB2 sample is approximately a factor of three higher than the ''as received'' SB3 sample. There also appears to be small

  12. Washed Away!

    Science.gov (United States)

    Cheek, Kim A.

    2013-01-01

    Earth's surface is constantly changing. Weathering, erosion, and deposition break down Earth materials, transport those materials, and place them in new locations. Children see evidence of these processes all around them. The sidewalk or playground surface cracks and has plants growing in it. Pieces of a rock wall or the sides of a building…

  13. Investigating Solutions to Wind Washing Issues in Two-Story Florida Homes, Phase 2

    Energy Technology Data Exchange (ETDEWEB)

    Withers, C. [Building America Partnership for Improved Residential Construction, Cocoa, FL (United States); Kono, J. [Building America Partnership for Improved Residential Construction, Cocoa, FL (United States)

    2015-04-01

    This report provides results from a second-phase research study of a phenomenon generally referred to as wind washing. Wind washing is the movement of unconditioned air around or through building thermal barriers in such a way as to diminish or nullify the intended thermal performance. In some cases, thermal and air barriers are installed very poorly or not at all, and air can readily move from unconditioned attic spaces into quasi-conditioned interstitial spaces. This study focused on the impact of poorly sealed and insulated floor cavities adjacent to attic spaces in Florida homes. In these cases, unconditioned attic air can be transferred into floor cavities through pathways driven by natural factors such as wind, or by thermal differences between the floor cavity and the attic. Air can also be driven into a floor cavity through mechanical forces imposed by return duct leakage in the floor cavity.

  14. Two-step impression/ injection, an alternative putty/ wash impression technique: case report.

    Science.gov (United States)

    Caputi, S; Murmura, G; Sinjari, B; Varvara, G

    2012-01-01

    We here describe a new technique for making a definitive impression that we refer to as the two-step impression/injection technique. This technique initially follows the classical one-step putty/ light-body impression technique with the polymerization of the putty and the light-body compound. This is then followed by the second step: injection of extra-light-body compound into the preparation through a hole in the metal stock tray. The aim of this additional step is to control the wash bulk and minimize the changes that can produce unfavorable impression results. This new two-step impression/injection technique allows displacement of soft tissues, such as the tongue, during the first seating of the putty and wash materials, while in the second step, the extra-light-body compound records all of the finer details without being compressed.

  15. Remediation of soils polluted with lindane using surfactant-aided soil washing and electrochemical oxidation.

    Science.gov (United States)

    Muñoz-Morales, M; Braojos, M; Sáez, C; Cañizares, P; Rodrigo, M A

    2017-10-05

    In this work the complete treatment of soil spiked with lindane is studied using surfactant-aided soil-washing (SASW) to exhaust lindane from soil and electrolysis with diamond anodes to mineralize lindane from the soil washing fluid (SWF) waste. Results demonstrated that this technological approach is efficient and allow to remove this hazardous pollutant from soil. They also pointed out the significance of the ratio surfactant/soil in the efficiency of the SASW process and in the performance of the later electrolysis used to mineralize the pollutant. Larger values of this parameter lead to effluents that undergo a very efficient treatment which allows the depletion of lindane for applied charges lower than 15AhL -1 and the recovery of more than 70% of the surfactant for the regeneration of the SWF. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. Organochlorine insecticides (DDT and heptachlor in dry fish: Traditional washing and cooking effect on dietary intake

    Directory of Open Access Journals (Sweden)

    Matiur Rahim

    2009-06-01

    Full Text Available The concentrations of organochlorine insecticides (DDT and heptachlor were investigated to estimate the effect of various washing and boiling/cooking to elucidate the concentration level we intake actually. For this study five most popular dry fish samples namely bombay duck (loittya, ribbon fish (chhuri, shrimp (chingri, chinese pomfret (rupchanda and Indian salmon (lakhua were analyzed. The highest concentrations of DDT and heptachlor were found 737.238 ppb (Indian salmon, normal and 44.806 ppb (shrimp, normal respectively; after boiling treatment a big amount was washed out and remained only 135.516 ppb and 16.868 ppb respectively. Boiling treatment was found more effective than the others.

  17. Effect of transoral tracheal wash on respiratory mechanics in dogs with respiratory disease.

    Science.gov (United States)

    Vaught, Meghan E; Rozanski, Elizabeth A; deLaforcade, Armelle M

    2018-01-01

    The purpose of this study was to determine the impact of a transoral tracheal wash (TOTW) on respiratory mechanics in dogs and to describe the use of a critical care ventilator (CCV) to determine respiratory mechanics. Fourteen client-owned dogs with respiratory diseases were enrolled. Respiratory mechanics, including static compliance (C stat ) and static resistance (R stat ), were determined before and after TOTW. Pre- and post-wash results were compared, with a P -value of mechanics, as observed by a reduction in C stat , presumably due to airway flooding and collapse. While no long-lasting effects were noted in these clinical patients, this effect should be considered when performing TOTW on dogs with respiratory diseases. Respiratory mechanics testing using a CCV was feasible and may be a useful clinical testing approach.

  18. Soil washing physical separations test procedure - 300-FF-1 operable unit

    Energy Technology Data Exchange (ETDEWEB)

    Belden, R.D.

    1993-10-08

    This procedure provides the operations approach, a field sampling plan, and laboratory procedures for a soil washing test to be conducted by Alternative Remedial Technologies, Inc. (ART) in the 300-FF-1 area at the Hanford site. The {open_quotes}Quality Assurance Project Plan for the Soil Washing Physical Separations Test, 300-FF-1 Operable Unit,{close_quotes} Hanford, Washington, Alternative Remedial Technologies, Inc., February 1994 (QAPP) is provided in a separate document that presents the procedural and organizational guidelines for this test. This document describes specifications, responsibilities, and general procedures to be followed to conduct physical separation soil treatability tests in the North Process Pond of the 300-FF-1 Operable Unit (OU) at the Hanford Site. These procedures are based on the {open_quotes}300-FF-1 Physical Separations CERCLA Treatability Test Plan, DOE/RL 92-2l,{close_quotes} (DOE-RL 1993).

  19. Efficiency of sugarcane bagasse-based sorbents for oil removal from engine washing wastewater.

    Science.gov (United States)

    Guilharduci, Viviane Vasques da Silva; Martelli, Patrícia Benedini; Gorgulho, Honória de Fátima

    2017-01-01

    This work evaluates the efficiency of sugarcane bagasse-based sorbents in the sorption of oil from engine washing wastewater. The sorbents were obtained from sugarcane bagasse in the natural form (SB-N) and modified with either acetic anhydride (SB-Acet) or 3-aminopropyltriethoxysilane (SB-APTS). The results showed that the sorption capacity of these materials decreased in the following order: SB-APTS > SB-N > SB-Acet. The superior oil sorption capacity observed for SB-APTS was attributed to the polar amino end groups in the silane structure, which acted to increase the hydrophilic character of the fibers. However, all the sorbents obtained in this study were able to clean a real sample of wastewater from engine washing, leading to significant reductions in suspended matter, sediment, anionic surfactants, and turbidity.

  20. Organochlorine insecticides (DDT and heptachlor in dry fish: traditional washing and cooking effect on dietary intake

    Directory of Open Access Journals (Sweden)

    MD. Nurul Huda Bhuiyan

    2009-03-01

    Full Text Available The concentrations of organochlorine insecticides (DDT and heptachlor were investigated to estimate the effect of various washing and boiling/cooking to elucidate the concentration level we intake actually. For this study five most popular dry fish samples namely bombay duck (loittya, ribbon fish (chhuri, shrimp (chingri, chinese pomfret (rupchanda and Indian salmon (lakhua were analyzed. The highest concentrations of DDT and heptachlor were found 737.238 ppb (Indian salmon, normal and 44.806 ppb (shrimp, normal respectively; after boiling treatment a big amount was washed out and remained only 135.516 ppb and 16.868 ppb respectively. Boiling treatment was found more effective than the others.

  1. A comparison of ethanol and methane fermentation of currant-and sultana-washing wastewater

    Energy Technology Data Exchange (ETDEWEB)

    Athanasopoulos, Nikolaos (Patras Univ. (Greece). Dept. of Chemistry)

    1994-01-01

    Wastewater from currant- and sultana-washing processes was successfully treated in an ethanol fermenter at 33[sup o]C; the pH of the wash water was controlled at 2.8; the reducing sugar content was 38.8 g/litre; commercial baker's yeast was used as inoculum at a concentration of 2.5 g/litre; formaldehyde at a concentration of 150 mg/litre was used as antiseptic; the ethanol yield was 70.6% of the theoretical value in 24 h; the COD removal after a single distillation was 84%. The overall economics of ethanol fermentation are very promising compared to methane fermentation. (author)

  2. RESOLUTION OF THE PROBLEM OF TREATMENT OF WASTE WATER GENERATED BY CAR WASHES AND TRANSPORT ENTERPRISES

    Directory of Open Access Journals (Sweden)

    Gogina Elena Sergeevna

    2012-12-01

    big cities of Russia. At the same time, the quality of the waste water treated by local water treatment stations fails to meet the present-day standard requirements. Moreover, potable water shall not be used for the purpose of washing transport vehicles. Within the recent 10 years, MGSU has developed a number of research projects aimed at the resolution of this problem. The concept developed by the MGSU specialists is to attain the highest quality of treated waste water generated by car washes and transport enterprises using the most advanced technologies of water treatment rather than to design new water treatment plants. Various methods may be applied for this purpose: restructuring of water treatment facilities, advanced feed, updated regulations governing the operation of water treatment plants.

  3. Soil washing physical separations test procedure - 300-FF-1 operable unit

    International Nuclear Information System (INIS)

    Belden, R.D.

    1993-01-01

    This procedure provides the operations approach, a field sampling plan, and laboratory procedures for a soil washing test to be conducted by Alternative Remedial Technologies, Inc. (ART) in the 300-FF-1 area at the Hanford site. The open-quotes Quality Assurance Project Plan for the Soil Washing Physical Separations Test, 300-FF-1 Operable Unit,close quotes Hanford, Washington, Alternative Remedial Technologies, Inc., February 1994 (QAPP) is provided in a separate document that presents the procedural and organizational guidelines for this test. This document describes specifications, responsibilities, and general procedures to be followed to conduct physical separation soil treatability tests in the North Process Pond of the 300-FF-1 Operable Unit (OU) at the Hanford Site. These procedures are based on the open-quotes 300-FF-1 Physical Separations CERCLA Treatability Test Plan, DOE/RL 92-2l,close quotes (DOE-RL 1993)

  4. Designing and Developing Automatic Trolley for Washing and Dressing the Wounds

    Directory of Open Access Journals (Sweden)

    Golvardi Yazdi M. S.

    2017-12-01

    Full Text Available Introduction:Many items are needed for dressing including sterile dressing set, antiseptic and washing solutions, leucoplast tape, waste bin for infectious garbage, waste bin for noninfectious garbage, safe disposal trash for sharp cutting instruments, bedpan and sometimes drugs. All the items are laid out on a simple wheeled trolley. The multiplicity of items together with problems in placing tools on trolley, forgetting some items, disturbing sterile condition, falling and damaging equipment and the need for at least two people for each procedure, all are the reasons to design and develop Automatic Trolley for Washing and Dressing the Wounds. Material and Method: To develop a mobile unit which meets our needs for dressing, the trolley patents registered in America and different companies were evaluated as well as the materials and methods used while dressing were considered. Results: Automatic Trolley for Washing and Dressing the Wounds was designed and developed. It comprises the followings: drawer, waste bin for infectious garbage, waste bin for noninfectious garbage, shelves for serum and betadine solution, serum stand, peristaltic pump, flexible tube for connecting serum, a place for bedpan, foot pedal for serum flow, two eye-sensor chambers for solution betadine and scrub, an auxiliary work surface. Conclusion: Due to the usual requirements for dressing, we have designed an equipped mobile unit which covers all the objectives of dressing and increases the speed of procedure. Moreover, due to the contrived equipment on the trolley, procedures are done quickly and second person is not required to assist. Automatic Trolley for Washing and Dressing the Wounds is made up of stainless steel which could be mass housing and commercializing which would play a deserving role in improving the fundamentals of health care and wound treatment.

  5. Bench Scale Treatability Studies of Contaminated Soil Using Soil Washing Technique

    OpenAIRE

    Gupta, M. K.; Srivastava, R. K.; Singh, A. K.

    2010-01-01

    Soil contamination is one of the most widespread and serious environmental problems confronting both the industrialized as well as developing nations like India. Different contaminants have different physicochemical properties, which influence the geochemical reactions induced in the soils and may bring about changes in their engineering and environmental behaviour. Several technologies exist for the remediation of contaminated soil and water. In the present study soil washing technique using...

  6. Nocardia nova identification in a transtracheal wash of a horse with recurrent airway obstruction

    OpenAIRE

    Condas, LAZ; Ribeiro, MG; Olivo, G; Franco, MMJ; Gonoi, T; Matsuzawa, T; Yazawa, K; Gonçalves, RC; Borges, AS

    2015-01-01

    A horse with recurrent airway disease was presented with dyspnea, mucopurulent bilateral nasal discharge and abnormal lung sounds. Microbiological culture, cytological examination and molecular identification (16S rRNA gene sequence) were performed with the transtracheal wash material and allowed the identification of Nocardia nova, an uncommon agent associated with equine respiratory abnormalities. Un equino con enfermedad pulmonar recurrente presentó disnea, secreción nasal purulenta bil...

  7. Influence of Industrial Washing and Cyclic Fatigue on Slippage of Linen Fabric Threads along the Seam

    Directory of Open Access Journals (Sweden)

    Irina KORUNČAK

    2014-04-01

    Full Text Available All seams of garments shall withstand the established force effect in the longitudinal and transverse directions. Resistance to thread slippage along the seam is a major property of fabrics that is regulated by strict guidelines. In many research works, lining fabrics are chosen as the object of research as thread slippage is the most typical of them. What concerns the reports exploring slippage of linen fabric threads along the seam, just very few papers are available. Studies dealing with the influence made by industrial washing and cyclic load on the defect under investigation, thereby taking into account operational properties of garments are not readily available at all. The objective of the paper is to define the influence of industrial washing and cyclic tensile on slippage of linen fabric threads along the seam. For the research, five 100 % linen fabrics of plain weave have been selected. Control test specimens, unwashed and processed with different washing methods, have been analysed. Cyclic tensile of the test specimens has been carried out by a tensile machine “Tinius Olsen” at tensile force P = 20 N, tensile speed of 12.55 mm/s, number of cycles of 100. The carried-out testing has demonstrated that industrial washing decreased resistance of linen fabrics to thread slippage along the seam in the most cases. Analysis of the results obtained has shown that cyclic tensile led to particularly significant increase in the seam gap. DOI: http://dx.doi.org/10.5755/j01.ms.20.1.2486

  8. Prevalence of Methicillin?Resistant Staphylococcus aureus from Equine Nasopharyngeal and Guttural Pouch Wash Samples

    OpenAIRE

    Boyle, A.G.; Rankin, S.C.; Duffee, L.A.; Morris, D.

    2017-01-01

    Background Methicillin?resistant Staphylococcus aureus (MRSA) is recognized as a cause of nosocomial infections in both human and veterinary medicine. Studies that examine the nasopharynx and guttural pouches of the horse as carriage sites for MRSA have not been reported. Hypothesis/Objective MRSA colonizes the nasopharynx and guttural pouch of horses. To determine the prevalence of MRSA in equine nasopharyngeal wash (NPW) and guttural pouch lavage (GPL) samples in a field population of horse...

  9. The influence of platinum washing-out time on its recovery from used auto catalytic converters

    Directory of Open Access Journals (Sweden)

    A. Fornalczyk

    2014-07-01

    Full Text Available The used catalytic converters contain small amounts of precious metals. Recovery of these metals is essential for environmental and economic reasons. This work presents a method of Platinum Group Metals (PGM recovery from auto catalytic converters in which they are washed out by a liquid metal. The magneto-hydro-dynamic pump was used to force circulation of liquid metal under the influence of electromagnetic fields The influence of process time on platinum recovery was also carried out.

  10. Comparing effects of washing, thermal treatments and gamma irradiation on quality of spices

    International Nuclear Information System (INIS)

    Farag Zaied, S.E.A.; Aziz, N.H.; Ali, A.M.

    1996-01-01

    Samples of 5 selected spices, black pepper (Piper nigrum), fennel (Foeniculum vulgare), coriander (Coriandrum sativum) and anise (Pimpinella anisum) seeds, and turmeric (Curcuma longa) rhizomes, obtained from the local market, were washed with pure tap water then dried at room temperature, subjected to a thermal treatment at 70 degrees C for 15 minutes or exposed to a gamma radiation source (5.0 or 10 kGy). The treatments were evaluated using microbiological and chemical studies

  11. Safety evaluation of the ESP sludge washing baselines runs. Revision 2

    International Nuclear Information System (INIS)

    Gupta, M.K.

    1993-01-01

    Purpose is to provide the technical basis for evaluation of unreviewed safety question for the Extended Sludge Processing (ESP) Sludge Washing Baseline Runs, which are necessary to resolve technical questions associated with process control (sludge suspension, sludge settling, heat transfer, temperature control). The sludge is currently stored in below-ground tanks and will be prepared for processing at the Defense Waste Processing Facility as part of the Integrated Waste Removal Program for Savannah River Site

  12. Process of recovery and reuse of the washing liquids from filters

    International Nuclear Information System (INIS)

    Flynn, G.C.

    1975-01-01

    The present invention relates to a backflush procedure intended for a repeated recovery and reuse of the liquid used for washing a 'pre-layer' filter. This type of filter is used for purifying the water of the steam generator circuit in electric energy generating plants equipped with steam turbines. Said 'pre-layer' filter can also be applied in the auxiliary facilities of electric energy generating plants, especially for treating the fuel ponds in nuclear reactors and for radioactive waste processing [fr

  13. Flotation of kaolinite from tailings of kaolin-washing plants by cationic collectors

    OpenAIRE

    Barani Kianoush

    2016-01-01

    Traditional processing of kaolin is achieved by dispersion of the mined ore and classification by means of multistage hydrocyclones. The inefficiencies inherent to cyclones produce a middling product that is commonly disposed back to the quarry. In this research recovery of kaolinite from tailings of the Zonoupz kaolin washing plant, which is located in Iran, was investigated by cationic flotation. Flotation experiments showed that flotation of kaolinite from tailings was much better in an ac...

  14. Recovery of kaolinite from tailings of Zonouz kaolin-washing plant by flotation-flocculation method

    OpenAIRE

    Kianoush Barani; Masoud Kalantari

    2018-01-01

    The traditional processing of kaolin is achieved by dispersion of the mined ore and classification by multistage hydrocyclone plants. The inefficiencies inherent to cyclones produce a middling product that is commonly disposed back into the quarry. In this research, recovery of kaolinite from tailings of Zonouz kaolin washing plant, which is located in Iran was investigated by flotation and flotation- flocculation. Flotation experiments show that the flotation of kaolinite from the tailings i...

  15. Disinfection potential of ozone, ultraviolet-C and their combination in wash water for the fresh-cut vegetable industry.

    Science.gov (United States)

    Selma, María V; Allende, Ana; López-Gálvez, Francisco; Conesa, María A; Gil, María I

    2008-09-01

    The purpose of this research was to investigate the disinfection efficacy of ozone (O(3)) and UV-C illumination (UV), and their combination (O(3)-UV) for reducing microbial flora of fresh-cut onion, escarole, carrot, and spinach wash waters collected from the industry. Furthermore, the influence of water physicochemical parameters on the decontamination efficacy and the effect of these technologies on physicochemical quality of wash water were analyzed. O(3), UV, and O(3)-UV were effective disinfection treatments on vegetable wash water, with a maximum microbial reduction of 6.6 log CFU mL(-1) after 60 min treatment with O(3)-UV. However, maximum total microbial reductions achieved by UV and O(3) treatments after 60 min were 4.0 and 5.9 log CFU mL(-1), lower than by O(3)-UV treatment. Furthermore, turbidity of wash water was reduced significantly by O(3) and O(3)-UV treatments, while UV treatment did not affect the physicochemical quality of the water. Conclusions derived from this study illustrate that O(3) and O(3)-UV are alternatives to other sanitizers used in the fresh-cut washing processes. The use of these technologies would allow less frequent changing of spent water and the use of much lower sanitizer doses. Nevertheless, in specific applications such as carrot wash water, where levels of undesirable microbial and chemical constituents are lower than other vegetable wash water, UV treatment could be an appropriate treatment considering cost-effectiveness criteria.

  16. Candida and Fusarium species known as opportunistic human pathogens from customer-accessible parts of residential washing machines.

    Science.gov (United States)

    Babič, Monika Novak; Zalar, Polona; Ženko, Bernard; Schroers, Hans-Josef; Džeroski, Sašo; Gunde-Cimerman, Nina

    2015-03-01

    Energy constraints have altered consumer practice regarding the use of household washing machines. Washing machines were developed that use lower washing temperatures, smaller amounts of water and biodegradable detergents. These conditions may favour the enrichment of opportunistic human pathogenic fungi. We focused on the isolation of fungi from two user-accessible parts of washing machines that often contain microbial biofilms: drawers for detergents and rubber door seals. Out of 70 residential washing machines sampled in Slovenia, 79% were positive for fungi. In total, 72 strains belonging to 12 genera and 26 species were isolated. Among these, members of the Fusarium oxysporum and Fusarium solani species complexes, Candida parapsilosis and Exophiala phaeomuriformis represented 44% of fungi detected. These species are known as opportunistic human pathogens and can cause skin, nail or eye infections also in healthy humans. A machine learning analysis revealed that presence of detergents and softeners followed by washing temperature, represent most critical factors for fungal colonization. Three washing machines with persisting malodour that resulted in bad smelling laundry were analysed for the presence of fungi and bacteria. In these cases, fungi were isolated in low numbers (7.5 %), while bacteria Micrococcus luteus, Pseudomonas aeruginosa, and Sphingomonas species prevailed. Copyright © 2014 The British Mycological Society. Published by Elsevier Ltd. All rights reserved.

  17. Gravity and magnetic data across the Ghost Dance Fault in WT-2 Wash, Yucca Mountain, Nevada

    International Nuclear Information System (INIS)

    Oliver, H.W.; Sikora, R.F.

    1994-01-01

    Detailed gravity and ground magnetic data were obtained in September 1993 along a 4,650 ft-long profile across the Ghost Dance Fault system in WT-2 Wash. Gravity stations were established every 150 feet along the profile. Total-field magnetic measurements made initially every 50 ft along the profile, then remade every 20 ft through the fault zone. These new data are part of a geologic and geophysical study of the Ghost Dance Fault (GDF) which includes detailed geologic mapping, seismic reflection, and some drilling including geologic and geophysical logging. The Ghost Dance Fault is the only through-going fault that has been identified within the potential repository for high-level radioactive waste at Yucca Mountain, Nevada. Preliminary gravity results show a distinct decrease of 0.1 to 0.2 mGal over a 600-ft-wide zone to the east of and including the mapped fault. The gravity decrease probably marks a zone of brecciation. Another fault-offset located about 2,000 ft to the east of the GDF was detected by seismic reflection data and is also marked by a distinct gravity low. The ground magnetic data show a 200-ft-wide magnetic low of about 400 nT centered about 100 ft east of the Ghost Dance Fault. The magnetic low probably marks a zone of brecciation within the normally polarized Topopah Spring Tuff, the top of which is about 170 ft below the surface, and which is known from drilling to extend to a depth of about 1,700 ft. Three-component magnetometer logging in drill hole WT-2 located about 2,700 ft east of the Ghost Dance Fault shows that the Topopah Spring Tuff is strongly polarized magnetically in this area, so that fault brecciation of a vertical zone within the Tuff could provide an average negative magnetic contrast of the 4 Am -1 needed to produce the 400 nT low observed at the surface

  18. Preservation Method and Phosphate Buffered Saline Washing Affect the Acute Myeloid Leukemia Proteome

    Directory of Open Access Journals (Sweden)

    Rebecca Wangen

    2018-01-01

    Full Text Available Acute myeloid leukemia (AML primary cells can be isolated from peripheral blood, suspended with media containing bovine serum and cryoprotectant, and stored in liquid nitrogen before being processed for proteomic analysis by mass spectrometry (MS. The presence of bovine serum and human blood proteins in AML samples can hamper the identifications of proteins, and thereby reduce the proteome coverage of the study. Herein, we have established the effect of phosphate buffered saline (PBS washing on AML patient samples stored in media. Although PBS washes effectively removed serum and blood contaminants, the saline wash resulted in cell burst and remarkable protein material loss. We also compared different methods to preserve the AML proteome from THP-1 and Molm-13 cell lines before MS analysis: (1 stored in media containing bovine serum and dimethyl sulfoxide (DMSO; (2 stored as dried cell pellets; and (3 stored as cell lysates in 4% sodium dodecyl sulfate (SDS. MS analysis of differently preserved AML cell samples shows that preservation with DMSO produce a high number of fragile cells that will burst during freezing and thawing. Our studies encourage the use of alternative preservation methods for future MS analysis of the AML proteome.

  19. Combining sieving and washing, a way to treat MSWI boiler fly ash.

    Science.gov (United States)

    De Boom, Aurore; Degrez, Marc

    2015-05-01

    Municipal Solid Waste Incineration (MSWI) fly ashes contain some compounds that could be extracted and valorised. A process based on wet sieving and washing steps has been developed aiming to reach this objective. Such unique combination in MSWI fly ash treatment led to a non-hazardous fraction from incineration fly ashes. More specifically, MSWI Boiler Fly Ash (BFA) was separately sampled and treated. The BFA finer particles (13wt%) were found to be more contaminated in Pb and Zn than the coarser fractions. After three washing steps, the coarser fractions presented leaching concentrations acceptable to landfill for non-hazardous materials so that an eventual subsequent valorisation may be foreseen. At the contrary, too much Pb leached from the finest particles and this fraction should be further treated. Wet sieving and washing permit thus to reduce the leachability of MSWI BFA and to concentrate the Pb and Zn contamination in a small (in particle size and volume) fraction. Such combination would therefore constitute a straightforward and efficient basis to valorise coarse particles from MSWI fly ashes. Copyright © 2015 Elsevier Ltd. All rights reserved.

  20. Mitigation of heavy metals in different vegetables through biological washing techniques

    Directory of Open Access Journals (Sweden)

    Muhammad Umair Sattar

    2015-12-01

    Full Text Available Availability of nutritious and healthy food is the foremost challenging issue in all over the word. Vegetables are essential part in human diet and considered as natural reserves of nutrients gifted by Almighty Allah to human beings. Heavy metals are among the most toxic food pollutants and their intake through diet leads to several disorders. The sources of heavy metal contamination include waste water irrigation, industrial emissions, transportation and application of metal-based pesticides. In Pakistan this situation is more alarming as vegetables grown in peri-urban areas have shown high incidence of heavy metals accumulation. In this study effort was made to mitigate different heavy metals (Ar, Cd, Cr and Pb in cauliflower, spinach, okra and brinjal collected from peri-urban areas through washing with different biological solutions. Heavy metals contents were determined by using Atomic Absorption Spectrophotometry (AAS. Vegetable showed high load of heavy metals in unwashed form that reduced significantly by washing with different biological solutions. Among the different biological solutions, washing of vegetables with 8% ginger solution was found to be more effective.

  1. Selective Removal of Uranium from the Washing Solution of Uranium-Contaminated Soil

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Seung Soo; Han, G. S.; Kim, G. N.; Koo, D. S.; Jeong, J. W.; Choi, J. W. [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2015-10-15

    This study examined selective removal methods of uranium from the waste solution by ion exchange resins or solvent extraction methods to reduce amount of the 2{sup nd} waste. Alamine-336, known as an excellent extraction reagent of uranium from the leaching solution of uranium ore, did not remove uranium from the acidic washing solution of soil. Uranyl ions in the acidic waste solution were sorbed on ampholyte resin with a high sorption efficiency, and desorbed from the resin by a washing with 0.5 M Na{sub 2}CO{sub 3} solution at 60 .deg. C. However, the uranium dissolved in the sulfuric acid solution was not sorbed onto the strong anion exchanger resins. A great amount of uranium-contaminated (U-contaminated) soil had been generated from the decommissioning of a uranium conversion plant. Our group has developed a decontamination process with washing and electrokinetic methods to decrease the amount of waste to be disposed of. However, this process generates a large amount of waste solution containing various metal ions.

  2. Arbi Care application increases preschool children's hand-washing self-efficacy among preschool children.

    Science.gov (United States)

    Arbianingsih; Utario, Yossy; Rustina, Yeni; Krianto, Tri; Ayubi, Dian

    2018-02-01

    This research aimed to examine the effectiveness of an Android mobile game application called Arbi Care as a means to prevent diarrhea and build self-efficacy in hand washing among preschool children. This research used a pre- and post-test control group and time series design approach. Respondents were chosen randomly from a group of four to six years children. The intervention group (n = 60) received Arbi Care intervention for 25 minutes, twice a week, for five weeks while the control group (n = 60) received standard education. Self-efficacy was measured by using questionnaire and observation. Measurement was carried out three times in the sixth, eight, and tenth week post-intervention. The data was analyzed using the GLMRM test. There was a significant increase in the average score of self-efficacy in hand washing for the intervention group versus the control group. Moreover, there were significant differences in the results of average scores in which the intervention group showed much better self-efficacy improvement over the control group during the first, second, and final post-test after the intervention was given (p Android-based educational game can be an effective medium to improve hand washing self-efficacy among preschool children, thus helping to prevent diarrhea. Copyright © 2018 Elsevier España, S.L.U. All rights reserved.

  3. Application of washed MSWI fly ash in cement composites: long-term environmental impacts.

    Science.gov (United States)

    Yang, Zhenzhou; Tian, Sicong; Liu, Lili; Wang, Xidong; Zhang, Zuotai

    2018-04-01

    In the present study, long-term environmental impacts of compact and ground cement composites, in which 30 wt.% of cement was replaced by washed municipal solid wastes incineration (MSWI) fly ash, were investigated for use in building industry. Consecutive leaching tests over a time span of 180 days were performed in acid water, deionized water, and saline water, respectively, with the accumulative concentration of different elements determined in the leachate. Different leaching behaviors are observed among different potential toxic elements (PTEs). For instance, higher concentrations of V in the leachate were observed from the compact cement composites than those from the ground ones. The concentration of Ba in the leachate increased with the decrease of particle size of the cement composites, and an initial increase in the leaching efficiency of Sn was followed by a clear decline with the leaching time. In addition, kinetic study revealed that the leaching behaviors of potential toxic elements follow a second-order model. The results demonstrated that the addition of washed MSWI fly ash into cement can contribute to the attrition resistance, indicating that the washed MSWI fly ash could be a promising alternative for cement as supplementary building materials.

  4. Effects of climate change on the wash-off of volatile organic compounds from urban roads.

    Science.gov (United States)

    Mahbub, Parvez; Goonetilleke, Ashantha; Ayoko, Godwin A; Egodawatta, Prasanna

    2011-09-01

    The predicted changes in rainfall characteristics due to climate change could adversely affect stormwater quality in highly urbanised coastal areas throughout the world. This in turn will exert a significant influence on the discharge of pollutants to estuarine and marine waters. Hence, an in-depth analysis of the effects of such changes on the wash-off of volatile organic compounds (VOCs) from urban roads in the Gold Coast region in Australia was undertaken. The rainfall characteristics were simulated using a rainfall simulator. Principal Component Analysis (PCA) and Multicriteria Decision tools such as PROMETHEE and GAIA were employed to understand the VOC wash-off under climate change. It was found that low, low to moderate and high rain events due to climate change will affect the wash-off of toluene, ethylbenzene, meta-xylene, para-xylene and ortho-xylene from urban roads in Gold Coast. Total organic carbon (TOC) was identified as predominant carrier of toluene, meta-xylene and para-xylene in 300 μm fractions under such dominant rain events due to climate change. However, ortho-xylene did not show such affinity towards either TOC or TSS (total suspended solids) under the simulated climatic conditions. Copyright © 2011 Elsevier B.V. All rights reserved.

  5. Revised cost savings estimate with uncertainty for enhanced sludge washing of underground storage tank waste

    International Nuclear Information System (INIS)

    DeMuth, S.

    1998-01-01

    Enhanced Sludge Washing (ESW) has been selected to reduce the amount of sludge-based underground storage tank (UST) high-level waste at the Hanford site. During the past several years, studies have been conducted to determine the cost savings derived from the implementation of ESW. The tank waste inventory and ESW performance continues to be revised as characterization and development efforts advance. This study provides a new cost savings estimate based upon the most recent inventory and ESW performance revisions, and includes an estimate of the associated cost uncertainty. Whereas the author's previous cost savings estimates for ESW were compared against no sludge washing, this study assumes the baseline to be simple water washing which more accurately reflects the retrieval activity along. The revised ESW cost savings estimate for all UST waste at Hanford is $6.1 B ± $1.3 B within 95% confidence. This is based upon capital and operating cost savings, but does not include development costs. The development costs are assumed negligible since they should be at least an order of magnitude less than the savings. The overall cost savings uncertainty was derived from process performance uncertainties and baseline remediation cost uncertainties, as determined by the author's engineering judgment

  6. 100 Area soil washing: Bench scale tests on 116-F-4 pluto crib soil

    Energy Technology Data Exchange (ETDEWEB)

    Field, J.G.

    1994-06-10

    The Pacific Northwest Laboratory conducted a bench-scale treatability study on a pluto crib soil sample from 100 Area of the Hanford Site. The objective of this study was to evaluate the use of physical separation (wet sieving), treatment processes (attrition scrubbing, and autogenous surface grinding), and chemical extraction methods as a means of separating radioactively-contaminated soil fractions from uncontaminated soil fractions. The soil washing treatability study was conducted on a soil sample from the 116-F-4 Pluto Crib that had been dug up as part of an excavation treatability study. Trace element analyses of this soil showed no elevated concentrations above typically uncontaminated soil background levels. Data on the distribution of radionuclide in various size fractions indicated that the soil-washing tests should be focused on the gravel and sand fractions of the 116-F-4 soil. The radionuclide data also showed that {sup 137}Cs was the only contaminant in this soil that exceeded the test performance goal (TPG). Therefore, the effectiveness of subsequent soil-washing tests for 116-F-4 soil was evaluated on the basis of activity attenuation of {sup 137}Cs in the gravel- and sand-size fractions.

  7. Basic characteristics of leachate produced by various washing processes for MSWI ashes in Taiwan.

    Science.gov (United States)

    Yang, Renbo; Liao, Wing-Ping; Wu, Pin-Han

    2012-08-15

    Approximately 19.2% of Taiwan's municipal solid waste (MSW) that passes through incineration disposal is converted into ashes (including bottom ash and fly ash). Although bottom ash can pass nearly all of the standards of the toxicity characteristic leaching procedure (TCLP), its high chloride content makes its reuse limited; it generally cannot be used as a fine aggregate material in concrete applications. This research examined washing four types of bottom ash (BA) and fly ash (FA) with water to reduce their chloride content. The optimal water intensity for washing pretreated bottom ash was found to be 7-8L of water per kg of bottom ash, and the optimal water intensity for washing untreated fly ash was found to be 20-25 L of water per kg of fly ash. Based on regression analyses of the chloride concentrations of the leachates and their electrical conductivity (EC) values, each MSW incineration plant has its own ash characteristics as well as a specific regression line in bottom or fly ash leachate. Clearly, it is possible to monitor the EC values of the leachates online by estimation from regression equations to determine the chloride concentrations in the leachates. Crown Copyright © 2012. Published by Elsevier Ltd. All rights reserved.

  8. Radionuclide contaminated soil: Laboratory study and economic analysis of soil washing. Final report

    International Nuclear Information System (INIS)

    Fuhrmann, M.; Zhou, H.; Patel, B.; Bowerman, B.; Brower, J.

    1996-01-01

    The objective of the work discussed in this report is to determine if soil washing is a feasible method to remediate contaminated soils from the Hazardous Waste Management Facility (HWMF) at Brookhaven National Laboratory (BNL). The contaminants are predominantly Cs-137 and Sr-90. The authors have assumed that the target activity for Cs-137 is 50 pCi/g and that remediation is required for soils having greater activities. Cs-137 is the limiting contaminant because it is present in much greater quantities than Sr-90. This work was done in three parts, in which they: estimated the volume of contaminated soil as a function of Cs-137 content, determined if simple removal of the fine grained fraction of the soil (the material that is less than 0.063 mm) would effectively reduce the activity of the remaining soil to levels below the 50 pCi/g target, assessed the effectiveness of chemical and mechanical (as well as combinations of the two) methods of soil decontamination. From this analysis the authors were then able to develop a cost estimate for soil washing and for a baseline against which soil washing was compared

  9. 100 Area soil washing: Bench scale tests on 116-F-4 pluto crib soil

    International Nuclear Information System (INIS)

    Field, J.G.

    1994-01-01

    The Pacific Northwest Laboratory conducted a bench-scale treatability study on a pluto crib soil sample from 100 Area of the Hanford Site. The objective of this study was to evaluate the use of physical separation (wet sieving), treatment processes (attrition scrubbing, and autogenous surface grinding), and chemical extraction methods as a means of separating radioactively-contaminated soil fractions from uncontaminated soil fractions. The soil washing treatability study was conducted on a soil sample from the 116-F-4 Pluto Crib that had been dug up as part of an excavation treatability study. Trace element analyses of this soil showed no elevated concentrations above typically uncontaminated soil background levels. Data on the distribution of radionuclide in various size fractions indicated that the soil-washing tests should be focused on the gravel and sand fractions of the 116-F-4 soil. The radionuclide data also showed that 137 Cs was the only contaminant in this soil that exceeded the test performance goal (TPG). Therefore, the effectiveness of subsequent soil-washing tests for 116-F-4 soil was evaluated on the basis of activity attenuation of 137 Cs in the gravel- and sand-size fractions

  10. Evaluation of radiocaesium wash-off by soil erosion from various land uses using USLE plots.

    Science.gov (United States)

    Yoshimura, Kazuya; Onda, Yuichi; Kato, Hiroaki

    2015-01-01

    Radiocaesium wash-off associated with soil erosion in different land use was monitored using USLE plots in Kawamata, Fukushima Prefecture, Japan after the Fukushima Dai-ichi Nuclear Power Plant accident. Parameters and factors relating to soil erosion and (137)Cs concentration in the eroded soil were evaluated based on the field monitoring and presented. The erosion of fine soil, which is defined as the fraction of soil overflowed along with discharged water from a sediment-trap tank, constituted a large proportion of the discharged radiocaesium. This indicated that the quantitative monitoring of fine soil erosion is greatly important for the accurate evaluation of radiocaesium wash-off. An exponential relationship was found between vegetation cover and the amount of eroded soil. Moreover, the radiocaesium concentrations in the discharged soil were greatly affected by the land use. These results indicate that radiocaesium wash-off related to vegetation cover and land use is crucially important in modelling radiocaesium migration. Copyright © 2014 Elsevier Ltd. All rights reserved.

  11. Efficiency of the surgical washing of hands with brush and without brush

    Directory of Open Access Journals (Sweden)

    Fresia Canales Carmona

    2013-10-01

    Full Text Available The purpose of this article is to establish the answer to a clinical question regarding the effectiveness ofpreoperative hygiene with hand washing brush or without it. This first technique has been performed on the skinto reduce transient bacteria and to inhibit the growth of resident microorganisms as a common and required actbefore any surgical procedure. Despite this measure and others such as prophylactic antibiotics, the mainoperative complication continues to be the surgical wound infection. Today, it is as prevalent as in the past withthe consequent negative effects derived from it, both for the institutions and for patients. Being controversialtoday which one is the most effective and safe surgical hand washing method for the binomial: professionalsurgical team/ patient, this study is done under the criteria of the Evidence-Based Nursing.A question was builtin PICO format (Personal, Intervention, Comparison and Outcome. After this is done, continues informationsearch in the databases GOOGLE ACADÉMICO, Pub Med, Cochrane y Base de Datos para la Investigación enEnfermería (BDIE We obtained 20 articles related to the topic of them 8, which fulfilled the set CASPe criteriato answer the clinical question, were analyzed. We conclude that washing hands with a brush is equally effectiveas without brush technique in terms of decreased of the superficial skin bacterial flora, although this technique hasadvantages over the traditional practice.

  12. Polyester Textiles as a Source of Microplastics from Households: A Mechanistic Study to Understand Microfiber Release During Washing.

    Science.gov (United States)

    Hernandez, Edgar; Nowack, Bernd; Mitrano, Denise M

    2017-06-20

    Microplastic fibers make up a large proportion of microplastics found in the environment, especially in urban areas. There is good reason to consider synthetic textiles a major source of microplastic fibers, and it will not diminish since the use of synthetic fabrics, especially polyester, continues to increase. In this study we provide quantitative data regarding the size and mass of microplastic fibers released from synthetic (polyester) textiles during simulated home washing under controlled laboratory conditions. Consideration of fabric structure and washing conditions (use of detergents, temperature, wash duration, and sequential washings) allowed us to study the propensity of fiber shedding in a mechanistic way. Thousands of individual fibers were measured (number, length) from each wash solution to provide a robust data set on which to draw conclusions. Among all the variables tested, the use of detergent appeared to affect the total mass of fibers released the most, yet the detergent composition (liquid or powder) or overdosing of detergent did not significantly influence microplastic release. Despite different release quantities due to the addition of a surfactant (approximately 0.025 and 0.1 mg fibers/g textile washed, without and with detergent, respectively), the overall microplastic fiber length profile remained similar regardless of wash condition or fabric structure, with the vast majority of fibers ranging between 100 and 800 μm in length irrespective of wash cycle number. This indicates that the fiber staple length and/or debris encapsulated inside the fabric from the yarn spinning could be directly responsible for releasing stray fibers. This study serves as a first look toward understanding the physical properties of the textile itself to better understand the mechanisms of fiber shedding in the context of microplastic fiber release into laundry wash water.

  13. Bacterial flora of processed broiler chicken skin after successive washings in mixtures of potassium hydroxide and lauric acid.

    Science.gov (United States)

    Hinton, Arthur; Cason, John A

    2008-08-01

    Changes in the size of populations of different groups of bacteria composing the normal flora of processed broiler skin were examined after each of five consecutive washings in mixtures of potassium hydroxide (KOH) and lauric acid (LA). Portions of skin from commercially processed broiler carcasses were washed in distilled water (control) or in mixtures of 0.25% KOH-0.5% LA or 0.5% KOH-1% LA by using a stomacher laboratory blender to agitate the skin in the solutions. After each wash, skin was transferred to fresh solutions, and washing was repeated to provide samples washed one to five times in each solution. Bacteria in rinsates of the washed skin were enumerated on plate count (PC) agar, Staphylococcus (STA) agar, Levine eosin methylene blue (EMB) agar, lactic acid bacteria (LAB) agar, and Perfringens (PER) agar with TSC supplement. Selected isolates recovered on each medium were identified. Overall, no significant differences were observed in numbers of bacteria recovered on PC, STA, or EMB agars from skin after repeated washing in water, but there were significant reductions in the number of bacteria recovered on LAB and PER agars. Repeated washing of skin in 0.25% KOH-0.5% LA or 0.5% KOH-1% LA generally produced significant reductions in the number of bacteria recovered on all media. Furthermore, no bacteria were recovered on PER agar from skin washed five times in 0.25% KOH-0.5% LA. Likewise, no bacteria were recovered on EMB or LAB agars from skin washed three or more times in 0.5% KOH-1% LA or on PER agar from skin washed four or five times in this solution. Staphylococcus spp. were identified as the skin isolates with the highest degree of resistance to the bactericidal activity of KOH-LA. Findings indicate that although bacteria may be continually shed from poultry skin after repeated washings, bactericidal surfactants can be used to remove and kill several types of bacteria found on the surface of the skin of processed broilers.

  14. Inhibition of haemoglobin-mediated lipid oxidation in washed cod muscle and cod protein isolates by Fucus vesiculosus extract and fraction

    DEFF Research Database (Denmark)

    Wang, Tao; Jonsdottir, Rosa; Kristinsson, Hordur

    2010-01-01

    washed cod muscle and protein isolates, phlorotannin-enriched ethyl acetate (EtOAc) fraction showed higher inhibitory effect than crude 80% ethanol (EtOH) extract. The addition of oligomeric phlorotannin-rich subfraction (LH-2) separated by Sephadex LH-20 chromatography, completely inhibited...... similar level of TPC and chemical antioxidant activities as oligomeric subfraction LH-2, it was far less efficient in model systems. These results suggest that other factors rather than the intrinsic reactivity toward radicals could be responsible for the inhibitory effect of phlorotannins on lipid...

  15. Evaluation of the effects of repeated hand washing, sunlight, smoke and dirt on the persistence of deltamethrin on insecticide-treated nets.

    Science.gov (United States)

    Kayedi, M H; Lines, J D; Haghdoost, A A; Vatandoost, M H; Rassi, Y; Khamisabady, K

    2008-08-01

    Field studies were carried out in Iran to evaluate the effect of various factors (washing, sun, smoke, dust and dirt) on the residual insecticidal activity of PermaNet (a brand of long-lasting insecticidal net), and on nets conventionally treated with deltamethrin (K-O Tab), using bioassay tests. Thirty-two nets were washed five or 15 times, and eight nets were not washed at all. Nets were washed vigorously in cold tap water (17 degrees C, pH 8.9) with a detergent. Hand rubbing continued for 3min. After washing, some nets were exposed to dense smoke from a dung-hay fire for 3min and were also left exposed to the dusty wind between washes. One group of nets was exposed to the sunlight for the full 3-d interval between washes; another was exposed to sunlight for just 3h after each wash; two other groups were kept in the shade. There was a significantly greater loss of activity in nets exposed to the sun throughout the 3-d interval between washes: that is, for a total of 15 to 45 d. However, short sunlight exposure (maximum 3h between washes) during drying did not have any effect. We did not find any significant effect of exposure to dirt, dust and smoke after washing. It is concluded that the effect of sun is much smaller than that of washing, and that drying nets for a few hours in the sun is not harmful.

  16. Kuldne Mask Tallinnasssssss! / Sergei Zhenovatsh ; interv. Hellar Bergmann

    Index Scriptorium Estoniae

    Zhenovatsh, Sergei

    2008-01-01

    Lavastaja Sergei Zhenovatsh oma Teatrikunsti Stuudiost, noortest näitlejatest, Eestist. Lavastaja on Eestis teatrifestivali "Kuldne mask Eestis" raames. 10.-11. okt. etendus Tallinnas, Salme Kultuurikeskuses Nikolai Gogoli näidend "Mängurid"

  17. Decolorization of molasses spent wash by the white-rot fungus Flavodon flavus, isolated from a marine habitat

    Digital Repository Service at National Institute of Oceanography (India)

    Raghukumar, C.; Rivonkar, G.

    Flavodon flavus (Klotzsch) Ryvarden, a basidiomycete (NIOCC strain 312) isolated from decomposing leaves of a sea grass, decolorized pigments in molasses spent wash (MSW) by 80% after 8 days of incubation, when used at concentrations of 10% and 50...

  18. Status report: Pretreatment chemistry evaluation FY1997 -- Wash and leach factors for the single-shell tank waste inventory

    Energy Technology Data Exchange (ETDEWEB)

    Colton, N.G.

    1997-08-01

    The wash factors will be used to partition the single-shell tank (SST) inventory into soluble and insoluble portions. The leach factors will be used to estimate the further removal of bulk analytes, such as chromium, aluminum, and phosphate, as well as minor components. Wash and leach factors are given here for 18 analytes, elements expected to drive the volume of material disposed of as high-level waste (HLW). These factors are determined by a weighting methodology developed earlier by this task. Tank-specific analyte inventory values depicted in Tank Waste Data Summary Worksheets, are calculated from concentrations obtained from characterization reports; the waste density; and the tank waste volume. The experimentally determined percentage of analytes removed by washing and leaching in a particular tank waste are translated into a mass (metric tons) in Experimental Washing and Leaching Data Summary Worksheets.

  19. Status report: Pretreatment chemistry evaluation FY1997 - Wash and leach factors for the single-shell tank waste inventory

    International Nuclear Information System (INIS)

    Colton, N.G.

    1997-08-01

    The wash factors will be used to partition the single-shell tank (SST) inventory into soluble and insoluble portions. The leach factors will be used to estimate the further removal of bulk analytes, such as chromium, aluminum, and phosphate, as well as minor components. Wash and leach factors are given here for 18 analytes, elements expected to drive the volume of material disposed of as high-level waste (HLW). These factors are determined by a weighting methodology developed earlier by this task. Tank-specific analyte inventory values depicted in Tank Waste Data Summary Worksheets, are calculated from concentrations obtained from characterization reports; the waste density; and the tank waste volume. The experimentally determined percentage of analytes removed by washing and leaching in a particular tank waste are translated into a mass (metric tons) in Experimental Washing and Leaching Data Summary Worksheets

  20. Evidence on the Effectiveness of Water, Sanitation, and Hygiene (WASH Interventions on Health Outcomes in Humanitarian Crises: A Systematic Review.

    Directory of Open Access Journals (Sweden)

    Anita Ramesh

    Full Text Available Water, sanitation, and hygiene (WASH interventions are amongst the most crucial in humanitarian crises, although the impact of the different WASH interventions on health outcomes remains unclear.To examine the quantity and quality of evidence on WASH interventions on health outcomes in humanitarian crises, as well as evaluate current evidence on their effectiveness against health outcomes in these contexts.A systematic literature review was conducted of primary and grey quantitative literature on WASH interventions measured against health outcomes in humanitarian crises occurring from 1980-2014. Populations of interest were those in resident in humanitarian settings, with a focus on acute crisis and early recovery stages of humanitarian crises in low and middle-income countries. Interventions of interest were WASH-related, while outcomes of interest were health-related. Study quality was assessed via STROBE/CONSORT criteria. Results were analyzed descriptively, and PRISMA reporting was followed.Of 3963 studies initially retrieved, only 6 published studies measured a statistically significant change in health outcome as a result of a WASH intervention. All 6 studies employed point-of-use (POU water quality interventions, with 50% using safe water storage (SWS and 35% using household water treatment (HWT. All 6 studies used self-reported diarrhea outcomes, 2 studies also reported laboratory confirmed outcomes, and 2 studies reported health treatment outcomes (e.g. clinical admissions. 1 study measured WASH intervention success in relation to both health and water quality outcomes; 1 study recorded uptake (use of soap as well as health outcomes. 2 studies were unblinded randomized-controlled trials, while 4 were uncontrolled longitudinal studies. 2 studies were graded as providing high quality evidence; 3 studies provided moderate and 1 study low quality evidence.The current evidence base on the impact of WASH interventions on health outcomes in