WorldWideScience

Sample records for wash monitoring wells

  1. Innovative Technology for Preparing Washing Liquid During Well Drilling

    Directory of Open Access Journals (Sweden)

    Davydenko A.N.

    2015-09-01

    Full Text Available Technology of washings liquid preparation is worked out. Prospects of the hydrodynamic supercavitation use for preparation of washing liquids during well drilling are substantiated. Theoretical research make it possible to set parameters and work out the construction of cavitational dispergator. The results of theoretical research found their confirmation during practical examinations and became the basis for creation of the technique of washing liquid preparation and construction of cavitational dispergator tested in production conditions.

  2. Leaching Behavior of Circulating Fluidised Bed MSWI Air Pollution Control Residue in Washing Process

    Directory of Open Access Journals (Sweden)

    Zhiliang Chen

    2016-09-01

    Full Text Available In this study, air pollution control (APC residue is conducted with water washing process to reduce its chloride content. A novel electrical conductivily (EC measurement method is proposed to monitor the dynamic change of chloride concentrations in leachate as well as the chloride content of the residue. The method equally applies to various washing processes with different washing time, liquid/solid ratio and washing frequency. The results show that washing effectively extracts chloride salts from APC residues, including those from circulating fluidized bed (CFB municipal solid waste incineration (MSWI. The most appropriate liquid/solid ratio and washing time in the first washing are found to be around 4 L water per kg of APC residue and 30 min, respectively, and washing twice is required to obtain maximum dissolution. The pH value is the major controlling factor of the heavy metals speciation in leachate, while chloride concentration also affects the speciation of Cd. Water washing causes no perceptible transfer of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs from the APC residue to leachate. The chloride concentration is strongly related with electrical conductivity (EC, as well as with the concentrations of calcium, sodium and potassium of washing water. Their regression analyses specify that soluble chloride salts and EC could act as an indirect indicator to monitor the change of chloride concentration and remaining chloride content, thus, contributing to the selection of the optimal washing conditions.

  3. An investigation of wash-off controlling parameters at urban and commercial monitoring sites.

    Science.gov (United States)

    Berretta, C; Gnecco, I; Lanza, L G; La Barbera, P

    2007-01-01

    The relationship between the parameters of the wash-off function and the controlling hydrologic variables are investigated in this paper, assuming that the pollutant generation process basically depends on the watershed rainfall-runoff response characteristics. Data collected during an intense monitoring program carried out by the Department of Environmental Engineering of the University of Genova (Italy) within a residential area, an auto dismantler facility, a tourism terminal and a urban waste truck depot are used to this aim. The observed runoff events are classified into different TSS mass delivery processes and the occurrence of the first flush phenomenon is also investigated. The correlation between the mathematical parameters describing the exponential process and the hydrological parameters of the corresponding rainfall-runoff event is analysed: runoff parameters and in particular the maximum flow discharge over the time of concentration of the drainage network are proposed as the controlling factor for the total mass of pollutant that is made available for wash-off during each runoff event.

  4. EFRT M-12 Issue Resolution: Solids Washing

    Energy Technology Data Exchange (ETDEWEB)

    Baldwin, David L.; Schonewill, Philip P.; Toth, James J.; Huckaby, James L.; Eslinger, Paul W.; Hanson, Brady D.; Kurath, Dean E.; Minette, Michael J.

    2009-08-14

    Pacific Northwest National Laboratory (PNNL) has been tasked by Bechtel National Inc. (BNI) on the River Protection Project-Hanford Tank Waste Treatment and Immobilization Plant (RPP-WTP) project to perform research and development activities to resolve technical issues identified for the Pretreatment Facility (PTF). The Pretreatment Engineering Platform (PEP) was designed, constructed, and operated as part of a plan to respond to issue M12, “Undemonstrated Leaching Processes.” The PEP is a 1/4.5-scale test platform designed to simulate the WTP pretreatment caustic leaching, oxidative leaching, ultrafiltration solids concentration, and slurry washing processes. The PEP replicates the WTP leaching processes using prototypic equipment and control strategies. Two operating scenarios were evaluated for the ultrafiltration process (UFP) and leaching operations. The first scenario has caustic leaching performed in the UFP-VSL-T01A/B ultrafiltration feed vessels, identified as Integrated Test A. The second scenario has caustic leaching conducted in the UFP-VSL-T02A ultrafiltration feed preparation vessel, identified as Integrated Test B. Washing operations in PEP Integrated Tests A and B were conducted successfully as per the approved run sheets. However, various minor instrumental problems occurred, and some of the process conditions specified in the run sheet were not met during the wash operations, such as filter-loop flow-rate targets not being met. Five analytes were selected based on full solubility and monitored in the post-caustic-leach wash as successful indicators of washing efficiency. These were aluminum, sulfate, nitrate, nitrite, and free hydroxide. Other analytes, including sodium, oxalate, phosphate, and total dissolved solids, showed indications of changing solubility; therefore, they were unsuitable for monitoring washing efficiency. In the post-oxidative-leach wash, two analytes with full solubility were selected as suitable indicators of washing

  5. Bacteriological aspects of hand washing: A key for health promotion and infections control

    Directory of Open Access Journals (Sweden)

    Ramezan Ali Ataee

    2017-01-01

    Full Text Available The aim of this review is to show the historical aspects of hands washing for healthy life and explains how can reduce the transmission of community-acquired infectious agents by healthcare workers and patients. This review article is prepared based on available database. The key words used were hands washing, risk assessment, hands hygiene, bacterial flora, contamination, infection, nosocomial, tap water, sanitizer, bacterial resistance, hands bacterial flora, washing methods, antiseptics, healthcare workers, healthcare personnel, from PubMed, ScienceDirect, Embase, Scopus, Web of Sciences, and Google Scholar. Data were descriptively analyzed. The insistence on hand washing has a history of 1400 years. The research results indicate that the bacteria released from the female washed hands in wet and dry condition was lower than from the male′s hands with a significance level (3 CFU vs. 8 CFU; confidence interval 95%, P ≤ 0.001. The valuable results of the study indicated that released amount of bacterial flora from wet hands is more than 10 times in compared to dry hands. In addition, established monitoring systems for washing hands before and after patient′s manipulation as well as after toilet were dominant indices to prevent the transfer of infectious agents to the patients. Increasing awareness and belief of the healthcare workers have shown an important role by about 30% reduction in the transfection. Hand washing could reduce the episodes of transmission of infectious agents in both community and healthcare settings. However, hand washing is an important key factor to prevent transmission of infectious agents to patients. There is no standard method for measuring compliance. Thus, permanent monitoring of hand washing to reduce the transmission of infections is crucial. Finally, the personnel must believe that hand washing is an inevitable approach to infection control.

  6. Optimal modes in designing processes for wash through and reinforcement of wells

    Energy Technology Data Exchange (ETDEWEB)

    Sukurenko, Ye I

    1979-01-01

    In order to find the optimal solutions in designing processes of wash through and reinforcement of wells, mathematical programs are written in the FORTRAN-2 algorithmic language for an M-222 computer. Used as the global criterior of optimization was the minimum expenditure for the passage of a well in assigned plan terms. Used in the acquisition of the optimal design decisions were three types of information masses: a mass of constant information, a mass of operational information and a mass of intermediate information. The techniques and the programs for producing the design solutions were sent for test operation to TatNIPIneft', and to the KIVTs of the ''Grozneft''' and ''Ukrneft''' unions and to AzNIPIneft'. The test operation of programs developed in the VNIIKRneft' made it possible to expose a number of deficiencies both in the methodological approach to the acquisition of the optimal design solutions, as well as in the formulation and solution of individual problems.

  7. Radiotracer study of wash load movement in a drum-type fabric washing machine using a gamma camera

    Energy Technology Data Exchange (ETDEWEB)

    Balt, A.P.; Brekel, L.D.M. van den; Vandecasteele, C.; Kolar, Z.

    1987-01-01

    A study was made of the movement of the wash loads in a drum-type washing machine. For this purpose a sup(99m)Tc source was attached to one or two separate textile pieces and the subsequent source positions were determined by means of a gamma-camera. The wash load movement pattern appears to depend on the type of textile material and its amount, as well as on the volume of water present in the washing machine.

  8. Radiotracer study of wash load movement in a drum-type fabric washing machine using a gamma camera

    International Nuclear Information System (INIS)

    Balt, A.P.; Brekel, L.D.M. van den; Vandecasteele, C.; Kolar, Z.

    1987-01-01

    A study was made of the movement of the wash loads in a drum-type washing machine. For this purpose a sup(99m)Tc source was attached to one or two separate textile pieces and the subsequent source positions were determined by means of a gamma-camera. The wash load movement pattern appears to depend on the type of textile material and its amount, as well as on the volume of water present in the washing machine. (author)

  9. Comparison of the laboratory standard washing using CIPAC washing agent and the domestic washing on three recommended types of long-lasting insecticidal mosquito nets.

    Science.gov (United States)

    Ouattara, Jean Pierre Nabléni; Louwagie, Johanna; Pigeon, Olivier; Spanoghe, Pieter

    2013-01-01

    One of the best ways to prevent malaria is the use of insecticide-treated bed nets. Manufacturers pursue easier, safer and more efficient nets. Hence, many studies on the efficacy and wash resistance using World Health Organization standards have been reported. The commonly used detergent is "Savon de Marseille", because it closely resembles actually used soaps. At the 54(th) Collaborative International Pesticides Analytical Council (CIPAC) Technical Meeting in 2010, it was suggested to replace it by a standardized "CIPAC washing agent". The aim of this study was to investigate the difference between a laboratory hand washing simulation using the CIPAC washing agent (method-1) and a domestic washing (method-2) on different bed nets, as well as the effect of the drying process on the release of active ingredient. Interceptor®, Permanet®2.0 and Netprotect® nets were used in three treatments, each repeated 20 times. The first treatment included method-1 washing and indoor drying. The second treatment included method-2 washing and indoor drying. The third treatment used method-2 washing and UV-drying. The residual insecticide contents were determined using gas chromatography. The washing procedure and the number of washes have a significant effect on the release of active ingredient. Statistically, the two washing methods have the same effect on removing the active ingredient from the Interceptor® and Permanet®2.0 net, but a significantly different influence on the Netprotect® nets. The drying process has no significant effect on the insecticide. Both washing procedures affected the amount of insecticide remaining on nets independently of the impregnation technology. The active ingredient decreases with the number of washing cycles following an exponential or logarithmic model for coated nets. The laboratory hand washing simulation had more impact on the decrease of active ingredient content of the Netprotect® nets. All net types seemed to be effectively

  10. Comparison of the laboratory standard washing using CIPAC washing agent and the domestic washing on three recommended types of long-lasting insecticidal mosquito nets.

    Directory of Open Access Journals (Sweden)

    Jean Pierre Nabléni Ouattara

    Full Text Available One of the best ways to prevent malaria is the use of insecticide-treated bed nets. Manufacturers pursue easier, safer and more efficient nets. Hence, many studies on the efficacy and wash resistance using World Health Organization standards have been reported. The commonly used detergent is "Savon de Marseille", because it closely resembles actually used soaps. At the 54(th Collaborative International Pesticides Analytical Council (CIPAC Technical Meeting in 2010, it was suggested to replace it by a standardized "CIPAC washing agent". The aim of this study was to investigate the difference between a laboratory hand washing simulation using the CIPAC washing agent (method-1 and a domestic washing (method-2 on different bed nets, as well as the effect of the drying process on the release of active ingredient.Interceptor®, Permanet®2.0 and Netprotect® nets were used in three treatments, each repeated 20 times. The first treatment included method-1 washing and indoor drying. The second treatment included method-2 washing and indoor drying. The third treatment used method-2 washing and UV-drying. The residual insecticide contents were determined using gas chromatography.The washing procedure and the number of washes have a significant effect on the release of active ingredient. Statistically, the two washing methods have the same effect on removing the active ingredient from the Interceptor® and Permanet®2.0 net, but a significantly different influence on the Netprotect® nets. The drying process has no significant effect on the insecticide.Both washing procedures affected the amount of insecticide remaining on nets independently of the impregnation technology. The active ingredient decreases with the number of washing cycles following an exponential or logarithmic model for coated nets. The laboratory hand washing simulation had more impact on the decrease of active ingredient content of the Netprotect® nets. All net types seemed to be

  11. Probabilistics since WASH-1400

    International Nuclear Information System (INIS)

    Whitehead, N.E.

    1980-01-01

    Literature since the issuing of WASH-1400 reactor safety study shows that although the methodology has been attacked, it stands criticism well. Contrary to the aim of the study, which was to give a realistic, rather than a conservative risk estimate, there are many conservatisms in it. The strongly attacked treatment of common mode failure involving the square bounding model is shown here to be very likely to give correct results - and the applications of it in WASH-1400 do not often give results different from using the mean instead of the median. The Three-Mile Island accident is not such as to change the conclusions of WASH-1400 regarding core melt probabilities

  12. WASH and gender in health care facilities: The uncharted territory.

    Science.gov (United States)

    Kohler, Petra; Renggli, Samuel; Lüthi, Christoph

    2017-11-08

    Health care facilities in low- and middle-income countries are high-risk settings, and face special challenges to achieving sustainable water, sanitation, and hygiene (WASH) services. Our applied interdisciplinary research conducted in India and Uganda analyzed six dimensions of WASH services in selected health care facilities, including menstrual hygiene management. To be effective, WASH monitoring strategies in health care facilities must include gender sensitive measures. We present a novel strategy, showing that applied gender sensitive multitool assessments are highly productive in assessments of WASH services and facilities from user and provider perspectives. We discuss its potential for applications at scale and as an area of future research.

  13. Use of pulsed neutron logging to evaluate perforation washing

    International Nuclear Information System (INIS)

    Dimon, C.A.

    1986-01-01

    This invention relates to the use of pulsed neutron logging techniques before and after perforation washing operations are performed to evaluate the degree of success of the perforation washing operations. Well logging operations of a type designed to respond to the difference between a formation immediately behind the well sheath and voids in the formation are performed both before and after the perforation washing operation. differences between the two resulting logs are then indicative of voids created by perforation washing. In a preferred embodiment, pulsed neutron logging is used as the logging technique, while a weighted brine having a high absorption cross section to pulsed neutrons is used as the perforation washing fluid

  14. Groundwater monitoring for deep-well injection

    International Nuclear Information System (INIS)

    Chia, Y.; Chiu, J.

    1994-01-01

    A groundwater monitoring system for detecting waste migration would not only enhance confidence in the long-term containment of injected waste, but would also provide early warnings of contamination for prompt responses to protect underground sources of drinking water (USDWs). Field experiences in Florida have demonstrated monitoring water quality and fluid pressure changes in overlying formations is useful in detecting the upward migration of injected waste. Analytical and numerical solutions indicate changes in these two monitoring parameters can vary on the basis of hydrogeologic characteristics, operation conditions, and the distances from the injection well to the monitoring wells and to the preferential hydrologic conduits. To detect waste migration through defects around the wellbore or the leaky containment interval, groundwater monitoring wells should be placed as close as possible to an injection well. In the vertical direction, a monitoring well completed in a permeable interbed within the containment interval is expected to have the highest potential for detecting upward migration. Another acceptable horizon for groundwater monitoring is the lower portion of the buffer brine aquifer immediately above the containment interval. Monitoring wells in USDWs may be needed when waste has been detected in deeper formations or when leakage out of well casings poses a concern. A monitoring well open to the injection interval is of little value in alleviating the concerns of long-term upward migration. Moreover, the installation of the well could create additional preferential pathways. Complications in groundwater monitoring may arise at existing injection sites, especially with prior releases. It is also important to recognize that monitoring in the vicinity of the wellbore may not be effective for detecting waste migration through unidentified unplugged wells or undetected transmissive fractures

  15. Car wash wastewater treatment and water reuse - a case study.

    Science.gov (United States)

    Zaneti, R N; Etchepare, R; Rubio, J

    2013-01-01

    Recent features of a car wash wastewater reclamation system and results from a full-scale car wash wastewater treatment and recycling process are reported. This upcoming technology comprises a new flocculation-column flotation process, sand filtration, and a final chlorination. A water usage and savings audit (22 weeks) showed that almost 70% reclamation was possible, and fewer than 40 L of fresh water per wash were needed. Wastewater and reclaimed water were characterized by monitoring chemical, physicochemical and biological parameters. Results were discussed in terms of aesthetic quality (water clarification and odour), health (pathological) and chemical (corrosion and scaling) risks. A microbiological risk model was applied and the Escherichia coli proposed criterion for car wash reclaimed water is 200 CFU 100 mL(-1). It is believed that the discussions on car wash wastewater reclamation criteria may assist institutions to create laws in Brazil and elsewhere.

  16. A wash fluid for drilling into a field

    Energy Technology Data Exchange (ETDEWEB)

    Belyakov, V M; Badzhurak, R F; Koptelova, Ye K; Rogovoy, V K; Sapozhnikov, N G

    1979-01-18

    A wash fluid is proposed, used in drilling wells in water and a content of 3-5% by weight starch products. To speed up destruction of the starch products, to the fluid are added amylolytic enzymes in the amount of 0.01-0.1 percent by weight of the starch products' weight. To lower the use of starch products, up to 3% clay can be added to the fluid. The wash fluid is prepared directly at the work site. Dry powder of modified starch is mixed with cold water until a colloidal solution is obtained. Such a wash fluid preserves the required structural-mechanical properties for 3-5 days, which ensures prompt drilling into the waterbearing layer and installation of the filter. Then, during the work process, 5-6 hours before the moment required for lowering the viscosity, to the wash fluid is added the amylolytic enzyme; under its influence, the starch molecules split up, and the viscosity drops sharply. Using this wash fluid enables a reduction in well construction times from the beginning of drilling to the end of development of the water-bearing layer, and a rise in outputs and well service lives by reducing sedimentation of the water-bearing formation and elimination of down times during work required while waiting for destruction of the starch wash fluid under natural conditions.

  17. Washing technology development for gravel contaminated with uranium

    Energy Technology Data Exchange (ETDEWEB)

    Park, Uk Ryang; Kim, Gye Nam; Kim, Seung Soo; Kim, Wan Suk; Moon, Jai Kwon [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2013-10-15

    The soil washing method has a short decontamination time and is economical. In addition, methods including phytoremediation, solidification/stabilization and bioremediation exist. Phytoremediation and bioremediation are economical, but have low remedial efficiency. In addition, bioremediation causes washing wastewater because it requires a washing process for the separation of microorganisms from the soils. In addition, solidification/stabilization is a commonly used methods, but eventually increases the volume of wastes. As mentioned above, many researches involved in the decontamination of radioactively contaminated soils have been actively processed. On the other hand, researches for decontaminating radioactively contaminated gravels are not being currently processed. In this study, we performed basic experiments using decontamination methods to decontaminate radioactively contaminated gravel. First, we measured the concentration of uranium in gravel included in uranium-contaminated soils and performed a washing experiment to monitor the tendency of uranium removal. In addition, when managing gravel with a low uranium-decontamination rate, we tried to satisfy the radioactivity concentration criteria for self-disposal in the wastes (0.4Bq/g or less) by performing a washing experiment after only a physical crushing process. We performed washing experiments to satisfy the radioactivity concentration criteria for self-disposal (0.4 Bq/g or less) in gravel included in radioactively contaminated soil. We performed washing experiments for gravel whose initial average concentration of uranium was 1.3Bq/g. In addition, the average concentration of uranium was 0.8Bq/g. Too increase the decontamination rate, we crushed the gravel with a jaw crusher and performed the washing experiments. The results were similar to the results without crushing. In addition, it was determined that the smaller the size of the gravel particles, the more efficient the uranium decontamination

  18. Water washes and caustic leaches of sludge from Hanford Tank S-101 and water washes of sludge from Hanford Tank C-103

    International Nuclear Information System (INIS)

    Hunt, R.D.; Collins, J.L.; Chase, C.W.

    1998-07-01

    In 1993, the Department of Energy (DOE) selected the enhanced sludge washing (ESW) process as the baseline for pretreatment of Hanford tank sludges. The ESW process uses a series of water washes and caustic leaches to separate nonradioactive components such as aluminum, chromium, and phosphate from the high-level waste sludges. If the ESW process is successful, the volume of immobilized high-level waste will be significantly reduced. The tests on the sludge from Hanford Tank S-101 focused on the effects of process variables such as sodium hydroxide concentration (1 and 3 M), temperature (70 and 95 C), and leaching time (5, 24, 72, and 168 h) on the efficacy of the ESW process with realistic liquid-to-solid ratios. Another goal of this study was to evaluate the effectiveness of water washes on a sludge sample from hanford Tank C-103. The final objective of this study was to test potential process control monitors during the water washes and caustic leaches with actual sludge. Both 137 Cs activity and conductance were measured for each of the water washes and caustic leaches. Experimental procedures, a discussion of results, conclusions and recommendations are included in this report

  19. Soil washing: From characterization to implementation

    International Nuclear Information System (INIS)

    Corden, F.L.; Groenendijk, E.

    1995-01-01

    Only recently has soil washing begun to be applied to remediation of contaminated soils in the US. The experience gained during full-scale and large pilot-scale projects points to the importance of soil and site characterization in correctly evaluating the applicability of soil washing to a site and determining accurate cost estimates for its implementation. This paper will discuss actual case studies of various treatability and pilot study approaches that led to successful evaluation and implementation of soil washing remedies. Soil washing is applicable to a broad variety of chemical contaminants. Target contaminants include metals, radionuclides, pesticides, polychlorinated biphenyls, polynuclear aromatic hydrocarbons and petroleum hydrocarbons, as well as combinations of these contaminants. Because the contaminants noted above are deposited in the soils in a variety of forms, the unit operations necessary to treat the soil vary. It is the diversity of the available treatment alternatives, and the ability to use the units in a variety of process flow configurations that result in a very broad definition of soil washing

  20. Late Washing efficiency

    International Nuclear Information System (INIS)

    Morrissey, M.F.

    1992-01-01

    Interim Waste Technology has demonstrated the Late Washing concept on the Experimental Laboratory Filter (ELF) at TNX. In two tests, washing reduced the [NO 2 - ] from 0.08 M to approximately 0.01 M on slurries with 2 year equivalent radiation exposures and 9.5 wt. % solids. For both washes, the [NO 2 - ] decreased at rates near theoretical for a constant volume stirred vessel, indicating approximately l00% washing efficiency. Permeate flux was greater than 0.05 gpm/ft 2 for both washes at a transmembrane pressure of 50 psi and flow velocity of 9 ft/sec

  1. Nasal Wash Treatment

    Science.gov (United States)

    ... Medications Alternative Therapies Nasal Wash Treatment Nasal Wash Treatment Make an Appointment Ask a Question Refer Patient The Centers for Disease Control (CDC) guidelines for preparing water used in a nasal wash are listed below. Many ...

  2. Abdominopelvic washings: A comprehensive review

    Directory of Open Access Journals (Sweden)

    Erika F Rodriguez

    2013-01-01

    Full Text Available Intraperitoneal spread may occur with gynecological epithelial neoplasms, as well as with non-gynecological malignancies, which may result in serosal involvement with or without concomitant effusion. Therefore, washings in patients with abdominopelvic tumors represent important specimens for cytologic examination. They are primarily utilized for staging ovarian cancers, although their role has decreased in staging of endometrial and cervical carcinoma. Abdominopelvic washings can be positive in a variety of pathologic conditions, including benign conditions, borderline neoplastic tumors, locally invasive tumors, or distant metastases. In a subset of cases, washings can be diagnostically challenging due to the presence of co-existing benign cells (e.g., mesothelial hyperplasia, endosalpingiosis, or endometriosis, lesions in which there is only minimal atypia (e.g., serous borderline tumors or scant atypical cells, and the rarity of specific tumor types (e.g., mesothelioma. Ancillary studies including immunocytochemistry and fluorescence in situ hybridization may be required in difficult cases to resolve the diagnosis. This article provides a comprehensive and contemporary review of abdominopelvic washings in the evaluation of gynecologic and non-gynecologic tumors, including primary peritoneal and mesothelial entities.

  3. Sludge pretreatment chemistry evaluation: Enhanced sludge washing separation factors

    International Nuclear Information System (INIS)

    Colton, N.G.

    1995-03-01

    This report presents the work conducted in Fiscal Year 1994 by the Sludge Pretreatment Chemistry Evaluation Subtask for the Tank Waste Remediation System (TWRS) Tank Waste Treatment Science Task. The main purpose of this task, is to provide the technical basis and scientific understanding to support TWRS baseline decisions and actions, such as the development of an enhanced sludge washing process to reduce the volume of waste that will require high-level waste (HLW) vitrification. One objective within the Sludge Pretreatment Chemistry Evaluation Subtask was to establish wash factors for various SST (single-shell tank) sludges. First, analytical data were compiled from existing tank waste characterization reports. These data were summarized on tank-specific worksheets that provided a uniform format for reviewing and comparing data, as well as the means to verify whether the data set for each tank was complete. Worksheets were completed for 27 SST wastes. The analytical water wash data provided tank-specific information about the fraction of each component that dissolves with water, i.e., an estimate of tank-specific wash factors for evaluating tank-by-tank processing. These wash data were then used collectively to evaluate some of the wash factors that are assumed for the overall SST waste inventory; specifically, wash factors for elements that would be found primarily in sludges. The final step in this study was to incorporate the characterization and wash factor data into a spreadsheet that provides insight into the effect of enhanced sludge washing on individual tank sludges as well as for groups of sludges that may be representative of different waste types. Spreadsheet results include the estimated mass and percentage of each element that would be removed with washing and leaching. Furthermore, estimated compositions are given of the final wash and leach streams and residual solids, in terms of both concentration and dry weight percent

  4. Data summary report: Southern sector monitoring well installations

    International Nuclear Information System (INIS)

    Jones, W.E.

    2000-01-01

    This report provides construction documentation for four double-screen monitoring wells installed as part of the groundwater monitoring strategy identified in the Groundwater Effectiveness Monitoring Strategy for the Proposed Southern Sector Phase I Groundwater Corrective Action (WSRC-RP-99-4114, Rev. 0, July 1999). The proposed corrective action includes In-Well Vapor Stripping Wells SSR-001 through SSR-012, designed to intercept and ameliorate the TCE and PCE plumes at the 500 parts per billion isoconcentration contour. The four monitoring wells (SSM-10, -15A, -16-, and -17) constructed during this project are designed to monitor the effectiveness of the In-Well Vapor Stripping Well system. One monitoring well (SSM-10) is located hydraulically upgradient of vapor stripping wells. The other three wells are located hydraulically downgradient of the vapor stripping wells. Four monitoring wells additional to those describe in this report will be installed for effectiveness monitoring in the future

  5. Monitoring system in reactor dry well

    International Nuclear Information System (INIS)

    Horie, Akira; Suzuki, Shun-ichi; Yamamoto, Shinji; Kubokawa, Toshihiko; Takagi, Sakae; Yokosawa, Makoto.

    1991-01-01

    A failed portion of a dry well in a BWR type reactor is monitored and identified from a remote place by a simple structure. That is, laser beams are irradiated under scanning to a portion to be monitored. Then, the reflection light is monitored by a light receiving and monitoring system, and abnormalities such as defects or leaks of monitored portion are optically detected by a remote viewing equipment. With such a constitution, the portion to be monitored in poor operation circumstances of the reactor dry well can always be monitored efficiently from a remote place. The device of the present invention does not undergo the effect of radiation noises, etc. and it is excellent in heat resistance and radiation resistance. (I.S.)

  6. Tank 4 Characterization, Settling, And Washing Studies

    International Nuclear Information System (INIS)

    Bannochie, C.; Pareizs, J.; Click, D.; Zamecnik, J.

    2009-01-01

    . (3) There is 19% more S than can be accounted for by IC sulfate measurement. This additional soluble S is detected by ICP-AES analysis of the supernate. (4) Total supernate and slurry sulfur by ICP-AES should be monitored during washing in addition to supernate sulfate in order to avoid under estimating the amount of sulfur species removed or remaining in the supernate. (5) OLI simulation calculations show that the presence of undissolved Burkeite in the Tank 4 sample is reasonable, assuming a small difference in the Na concentration that is well within the analytical uncertainties of the reported value. The following conclusions were drawn from the blend studies of Tank 4 and decanted Tank 51-E1: (1) The addition of Tank 4 slurry to a decanted Tank 51-E1 sample significantly improved the degree and time for settling. (2) The addition of Tank 4 slurry to a decanted Tank 51-E1 sample significantly improved the plastic viscosity and yield stress. (3) The SRNL washing test, where nearly all of the wash solution was decanted from the solids, indicates that approximately 96% or more of the total S was removed from the blend in these tests, and the removal of the sulfur tracks closely with that of Na. Insoluble (undissolved) S remaining in the washed sludge was calculated from an estimate of the final slurry liquid fraction, the S result in the slurry digestion, and the S in the final decant (which was very close to the method detection limit). Based on this calculated result, about 4% of the initial total S remained after these washes; this amount is equivalent to about 18% of the initially undissolved S

  7. Evaluation of radiocaesium wash-off by soil erosion from various land uses using USLE plots

    International Nuclear Information System (INIS)

    Yoshimura, Kazuya; Onda, Yuichi; Kato, Hiroaki

    2015-01-01

    Radiocaesium wash-off associated with soil erosion in different land use was monitored using USLE plots in Kawamata, Fukushima Prefecture, Japan after the Fukushima Dai-ichi Nuclear Power Plant accident. Parameters and factors relating to soil erosion and 137 Cs concentration in the eroded soil were evaluated based on the field monitoring and presented. The erosion of fine soil, which is defined as the fraction of soil overflowed along with discharged water from a sediment-trap tank, constituted a large proportion of the discharged radiocaesium. This indicated that the quantitative monitoring of fine soil erosion is greatly important for the accurate evaluation of radiocaesium wash-off. An exponential relationship was found between vegetation cover and the amount of eroded soil. Moreover, the radiocaesium concentrations in the discharged soil were greatly affected by the land use. These results indicate that radiocaesium wash-off related to vegetation cover and land use is crucially important in modelling radiocaesium migration. - Highlights: • Fine soil erosion showed large impact on radiocaesium wash-off. • Exponential relationship was found between vegetation cover and eroded soil. • Radiocaesium concentration in the discharged soil was depending on land use

  8. Soil washing and post-wash biological treatment of petroleum hydrocarbon contaminated soils

    OpenAIRE

    Bhandari, Alok

    1992-01-01

    A laboratory scale study was conducted to investigate the treatability of petroleum contaminated soils by soil washing and subsequent biological treatment of the different soil fractions. In addition to soils obtained from contaminated sites, studies were also performed on soils contaminated in the laboratory. Soil washing was performed using a bench-scale soil washing system. Washing was carried out with simultaneous fractionation of the bulk soil into sand, silt and clay fractions. Cl...

  9. Evaluation of radiocaesium wash-off by soil erosion from various land uses using USLE plots.

    Science.gov (United States)

    Yoshimura, Kazuya; Onda, Yuichi; Kato, Hiroaki

    2015-01-01

    Radiocaesium wash-off associated with soil erosion in different land use was monitored using USLE plots in Kawamata, Fukushima Prefecture, Japan after the Fukushima Dai-ichi Nuclear Power Plant accident. Parameters and factors relating to soil erosion and (137)Cs concentration in the eroded soil were evaluated based on the field monitoring and presented. The erosion of fine soil, which is defined as the fraction of soil overflowed along with discharged water from a sediment-trap tank, constituted a large proportion of the discharged radiocaesium. This indicated that the quantitative monitoring of fine soil erosion is greatly important for the accurate evaluation of radiocaesium wash-off. An exponential relationship was found between vegetation cover and the amount of eroded soil. Moreover, the radiocaesium concentrations in the discharged soil were greatly affected by the land use. These results indicate that radiocaesium wash-off related to vegetation cover and land use is crucially important in modelling radiocaesium migration. Copyright © 2014 Elsevier Ltd. All rights reserved.

  10. Use of a patient hand hygiene protocol to reduce hospital-acquired infections and improve nurses' hand washing.

    Science.gov (United States)

    Fox, Cherie; Wavra, Teresa; Drake, Diane Ash; Mulligan, Debbie; Bennett, Yvonne Pacheco; Nelson, Carla; Kirkwood, Peggy; Jones, Louise; Bader, Mary Kay

    2015-05-01

    Critically ill patients are at marked risk of hospital-acquired infections, which increase patients' morbidity and mortality. Registered nurses are the main health care providers of physical care, including hygiene to reduce and prevent hospital-acquired infections, for hospitalized critically ill patients. To investigate a new patient hand hygiene protocol designed to reduce hospital-acquired infection rates and improve nurses' hand-washing compliance in an intensive care unit. A preexperimental study design was used to compare 12-month rates of 2 common hospital-acquired infections, central catheter-associated bloodstream infection and catheter-associated urinary tract infection, and nurses' hand-washing compliance measured before and during use of the protocol. Reductions in 12-month infection rates were reported for both types of infections, but neither reduction was statistically significant. Mean 12-month nurse hand-washing compliance also improved, but not significantly. A hand hygiene protocol for patients in the intensive care unit was associated with reductions in hospital-acquired infections and improvements in nurses' hand-washing compliance. Prevention of such infections requires continuous quality improvement efforts to monitor lasting effectiveness as well as investigation of strategies to eliminate these infections. ©2015 American Association of Critical-Care Nurses.

  11. Use of green washing fluids in a washing process for dioxin contaminated soils

    Directory of Open Access Journals (Sweden)

    Siwalee Yotapukdee

    2017-09-01

    Full Text Available High levels of dioxin contamination in soil have significant environmental challenges. Soil washing is a successful remediation process that is primarily used to treat coarse soils. Several literature studies have used various kinds of chemical washing liquids to remove dioxins from soils, though there are secondary environmental effects. This study intends to develop environmentally friendly soil washing methods that are effective in dioxin removal at an acceptable cost. Sugarcane wine, compost leachate, and ground fish broth were chosen as potential washing liquids. Each washing liquid was analyzed to determine its content of semivolatile organic compounds (SVOCs and volatile organic compounds (VOCs. These compounds are related to their bio-surfactant content. Several of the identified compounds had properties to help remove dioxins from contaminated soil. In the experiments, high removal efficiencies were observed, up to 70%~95% after five to six washes. Although effective removal was observed, a significant amount of wastewater was produced and the problems were not completely resolved. Thus, the optimal washing conditions are necessary to minimize the overall costs, while improving the process effectiveness. Moreover, an appropriate treatment method is required for wastewater containing dioxins.

  12. Treatment of car wash wastewater by UF membranes

    Science.gov (United States)

    Istirokhatun, Titik; Destianti, Puti; Hargianintya, Adenira; Oktiawan, Wiharyanto; Susanto, Heru

    2015-12-01

    The existence of car wash service facilitates car owners to remove dirt and grime from their vehicles. However, the dirt washed off vehicles as well as the cleaning materials themselves may be harmful to the environment if they are not properly managed and discharged. Many technologies have been proposed to treat car wash wastewater such as coagulation flocculation, tricking filter and flocculation-flotation. Nevertheless, these technologies have low efficiency to eliminate oil and small organic compounds. Ultrafiltration (UF) membranes were used in this study to treat car wash wastewater. This study investigated the performance of UF membranes under various pressures to remove COD, oil and grease, and also turbidity from car wash waste water. The membrane performance was examined by investigation of permeate flux and membrane rejection. The results meet the standard of environmental regulation and it is possible to be reused. The highest rejection was shown by PES10 (polyethersulfone 10 kDa) in 1 bar operation with complete rejection for both turbidity and oil and grace and 95% rejection for COD.

  13. Impact of electrochemical treatment of soil washing solution on PAH degradation efficiency and soil respirometry

    International Nuclear Information System (INIS)

    Mousset, Emmanuel; Huguenot, David; Hullebusch, Eric D. van; Oturan, Nihal; Guibaud, Gilles; Esposito, Giovanni; Oturan, Mehmet A.

    2016-01-01

    The remediation of a genuinely PAH-contaminated soil was performed, for the first time, through a new and complete investigation, including PAH extraction followed by advanced oxidation treatment of the washing solution and its recirculation, and an analysis of the impact of the PAH extraction on soil respirometry. The study has been performed on the remediation of genuine PAH-contaminated soil, in the following three steps: (i) PAH extraction with soil washing (SW) techniques, (ii) PAH degradation with an electro-Fenton (EF) process, and (iii) recirculation of the partially oxidized effluent for another SW cycle. The following criteria were monitored during the successive washing cycles: PAH extraction efficiency, PAH oxidation rates and yields, extracting agent recovery, soil microbial activity, and pH of soil. Two representative extracting agents were compared: hydroxypropyl-beta-cyclodextrin (HPCD) and a non-ionic surfactant, Tween"® 80. Six PAH with different numbers of rings were monitored: acenaphthene (ACE), phenanthrene (PHE), fluoranthene (FLA), pyrene (PYR), benzo(a)pyrene (BaP), and benzo(g,h,i)perylene (BghiP). Tween"® 80 showed much better PAH extraction efficiency (after several SW cycles) than HPCD, regardless of the number of washing cycles. Based on successive SW experiments, a new mathematical relation taking into account the soil/water partition coefficient (Kd*) was established, and could predict the amount of each PAH extracted by the surfactant with a good correlation with experimental results (R"2 > 0.975). More HPCD was recovered (89%) than Tween"® 80 (79%), while the monitored pollutants were completely degraded (>99%) after 4 h and 8 h, respectively. Even after being washed with partially oxidized solutions, the Tween"® 80 solutions extracted significantly more PAH than HPCD and promoted better soil microbial activity, with higher oxygen consumption rates. Moreover, neither the oxidation by-products nor the acidic media (p

  14. Characterization of wastewaters from vehicle washing companies and environmental impacts

    Directory of Open Access Journals (Sweden)

    Valderi Duarte Leite

    2011-12-01

    Full Text Available The car wash business has developed rapidly in recent years due to the increased number of cars, thus, it can cause serious environmental problems considering its potential source of pollution. The aim of this study was to characterize the wastewater from car washing companies in the city of Campina Grande, in Paraiba state, and to analyze the environmental impacts generated. A survey was conducted from November 2009 to July 2010. The first step we present a survey of car wash businesses in the city, and identified 20 licensed companies in which we evaluated the number of vehicles washed per week, the existence of a system of pre-treatment of wastewater generated and infrastructure that would allow the realization of the collection of samples of the effluent, the second step was carried out chemical and physical characterization of wastewater from five 20 companies surveyed in the previous step, and third stage were measured pollution loads of wastewater from washing of vehicles in the city, from the results obtained in previous steps. The characterization parameters were analyzed: oil and grease, COD, heavy metals, TS, TSS, turbidity, TKN, total P, pH and color. The results demonstrated that the wastewater from the car wash establishments shows high concentrations of organic matter, oils and grease, heavy metals and solids, and as such did not conform with the specific environmental legislation. Evaluation of pollutant loads demonstrated that if releases without proper treatment, it can cause serious environmental problems. It is therefore essential that these establishments are properly monitored.

  15. Perspectives on wellness self-monitoring tools for older adults.

    Science.gov (United States)

    Huh, Jina; Le, Thai; Reeder, Blaine; Thompson, Hilaire J; Demiris, George

    2013-11-01

    Our purpose was to understand different stakeholder perceptions about the use of self-monitoring tools, specifically in the area of older adults' personal wellness. In conjunction with the advent of personal health records, tracking personal health using self-monitoring technologies shows promising patient support opportunities. While clinicians' tools for monitoring of older adults have been explored, we know little about how older adults may self-monitor their wellness and health and how their health care providers would perceive such use. We conducted three focus groups with health care providers (n=10) and four focus groups with community-dwelling older adults (n=31). Older adult participants' found the concept of self-monitoring unfamiliar and this influenced a narrowed interest in the use of wellness self-monitoring tools. On the other hand, health care provider participants showed open attitudes toward wellness monitoring tools for older adults and brainstormed about various stakeholders' use cases. The two participant groups showed diverging perceptions in terms of: perceived uses, stakeholder interests, information ownership and control, and sharing of wellness monitoring tools. Our paper provides implications and solutions for how older adults' wellness self-monitoring tools can enhance patient-health care provider interaction, patient education, and improvement in overall wellness. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  16. Perspectives on Wellness Self-Monitoring Tools for Older Adults

    Science.gov (United States)

    Huh, Jina; Le, Thai; Reeder, Blaine; Thompson, Hilaire J.; Demiris, George

    2013-01-01

    Purpose Our purpose was to understand different stakeholder perceptions about the use of self-monitoring tools, specifically in the area of older adults’ personal wellness. In conjunction with the advent of personal health records, tracking personal health using self-monitoring technologies shows promising patient support opportunities. While clinicians’ tools for monitoring of older adults have been explored, we know little about how older adults may self-monitor their wellness and health and how their health care providers would perceive such use. Methods We conducted three focus groups with health care providers (n=10) and four focus groups with community-dwelling older adults (n=31). Results Older adult participants’ found the concept of self-monitoring unfamiliar and this influenced a narrowed interest in the use of wellness self-monitoring tools. On the other hand, health care provider participants showed open attitudes towards wellness monitoring tools for older adults and brainstormed about various stakeholders’ use cases. The two participant groups showed diverging perceptions in terms of: perceived uses, stakeholder interests, information ownership and control, and sharing of wellness monitoring tools. Conclusions Our paper provides implications and solutions for how older adults’ wellness self-monitoring tools can enhance patient-health care provider interaction, patient education, and improvement in overall wellness. PMID:24041452

  17. Impact of electrochemical treatment of soil washing solution on PAH degradation efficiency and soil respirometry.

    Science.gov (United States)

    Mousset, Emmanuel; Huguenot, David; van Hullebusch, Eric D; Oturan, Nihal; Guibaud, Gilles; Esposito, Giovanni; Oturan, Mehmet A

    2016-04-01

    The remediation of a genuinely PAH-contaminated soil was performed, for the first time, through a new and complete investigation, including PAH extraction followed by advanced oxidation treatment of the washing solution and its recirculation, and an analysis of the impact of the PAH extraction on soil respirometry. The study has been performed on the remediation of genuine PAH-contaminated soil, in the following three steps: (i) PAH extraction with soil washing (SW) techniques, (ii) PAH degradation with an electro-Fenton (EF) process, and (iii) recirculation of the partially oxidized effluent for another SW cycle. The following criteria were monitored during the successive washing cycles: PAH extraction efficiency, PAH oxidation rates and yields, extracting agent recovery, soil microbial activity, and pH of soil. Two representative extracting agents were compared: hydroxypropyl-beta-cyclodextrin (HPCD) and a non-ionic surfactant, Tween(®) 80. Six PAH with different numbers of rings were monitored: acenaphthene (ACE), phenanthrene (PHE), fluoranthene (FLA), pyrene (PYR), benzo(a)pyrene (BaP), and benzo(g,h,i)perylene (BghiP). Tween(®) 80 showed much better PAH extraction efficiency (after several SW cycles) than HPCD, regardless of the number of washing cycles. Based on successive SW experiments, a new mathematical relation taking into account the soil/water partition coefficient (Kd*) was established, and could predict the amount of each PAH extracted by the surfactant with a good correlation with experimental results (R(2) > 0.975). More HPCD was recovered (89%) than Tween(®) 80 (79%), while the monitored pollutants were completely degraded (>99%) after 4 h and 8 h, respectively. Even after being washed with partially oxidized solutions, the Tween(®) 80 solutions extracted significantly more PAH than HPCD and promoted better soil microbial activity, with higher oxygen consumption rates. Moreover, neither the oxidation by-products nor the acidic media (p

  18. Basic characteristics of leachate produced by various washing processes for MSWI ashes in Taiwan.

    Science.gov (United States)

    Yang, Renbo; Liao, Wing-Ping; Wu, Pin-Han

    2012-08-15

    Approximately 19.2% of Taiwan's municipal solid waste (MSW) that passes through incineration disposal is converted into ashes (including bottom ash and fly ash). Although bottom ash can pass nearly all of the standards of the toxicity characteristic leaching procedure (TCLP), its high chloride content makes its reuse limited; it generally cannot be used as a fine aggregate material in concrete applications. This research examined washing four types of bottom ash (BA) and fly ash (FA) with water to reduce their chloride content. The optimal water intensity for washing pretreated bottom ash was found to be 7-8L of water per kg of bottom ash, and the optimal water intensity for washing untreated fly ash was found to be 20-25 L of water per kg of fly ash. Based on regression analyses of the chloride concentrations of the leachates and their electrical conductivity (EC) values, each MSW incineration plant has its own ash characteristics as well as a specific regression line in bottom or fly ash leachate. Clearly, it is possible to monitor the EC values of the leachates online by estimation from regression equations to determine the chloride concentrations in the leachates. Crown Copyright © 2012. Published by Elsevier Ltd. All rights reserved.

  19. Bulk laundry monitoring system

    International Nuclear Information System (INIS)

    Thakur, Vaishali M.; Jain, Amit; Verma, Amit; Anilkumar, S.; Babu, D.A.R.; Sharma, D.N.; Rande, N.R.; Singh, B.N.

    2012-01-01

    Protective wear (like boiler suits, hand gloves etc.) is essential while handling radioactive material in plants/laboratories. During the course of work, it is quite possible that protective wear may get contaminated. These protective wears are packed in laundry bags and send to Decontamination Centre (DC). There is a need for monitoring the laundry bags at the time of receipt, as well as before dispatch to respective locations to comply with AERB guidelines, To avoid cross contamination during wash cycle, contaminated bags (> 0.5 mR/h on surface) need to be segregated. Present paper describes the development of such system for monitoring surface dose rate on bags at the time of receipt. The system installed at ETP after calibration, effectively segregates the contaminated bags from the rest and prevents from cross contamination during wash cycle. Reduction in man-rem consumption due to semi automatic monitoring. Improved sensitivity due to good geometry, long counting time, background and attenuation corrections. Optimum utilization of decontamination chemicals based on level of contamination and keeping track of its inventory. Generation of decontamination process data base for improvement

  20. Monitoring Animal Well-being

    DEFF Research Database (Denmark)

    Gronskyte, Ruta

    environment. In video surveillance, the behavior of humans and animals is monitored based on extremes: event is present/event is not present, objects behave normally/objects behave abnormally, action 1/action 2/action 3, etc. In nature, the motion of humans and animals is continuous with transitions from one...... action to another. The second aim of this thesis is to propose a method to monitor motion as a continuous process using common classification methods....... are handled. Ensuring the well-being of such large numbers of pigs using only personnel is a complicated task. Video surveillance of humans has been widely used to ensure safety and order in multiple situations. Methods have been developed to detect individual actions or abnormal behavior in small groups...

  1. Design and optimisation of purification procedure for biodiesel washing

    Directory of Open Access Journals (Sweden)

    S.B. Glišić

    2009-09-01

    Full Text Available Almost complete methanolysis of triglycerides is usually not enough to fulfil the strict standards of biodiesel quality. A key step in this process is neutralization of alkali (catalyst followed by the washing procedure necessary for removing different impurities such as traces of catalyst and methanol and removal of soaps and glycerol from esters phase. The washing with hot water is still widely used in many industrial units for the biodiesel production. In this study, different procedures of biodiesel washing using hot water were investigated. The orto-phosphoric acid was suggested as the best compound for alkali catalyst (sodium hydroxide neutralization. The main goal of the performed analysis was to minimize the water usage in the washing-neutralization step during the biodiesel production. Such solution would make the process of biodiesel synthesis more economical taking into account the decrease of energy consumed for evaporation of water during the final product purification, as well as more acceptable procedure related to the impact on environment (minimal waste water release. Results of the performed simulation of the washing process supported by original experimental data suggested that neutralization after the optimized washing process of the methyl ester layer could be the best solution. The proposed washing procedure significantly decreases the amount of waste water giving at the same time the desired purity of final products (biodiesel and glycerol. The simulation of the process was performed using ASPEN plus software supported by ELCANTREL and UNIQUAC procedure of required properties calculation

  2. 27 CFR 19.328 - Wash water.

    Science.gov (United States)

    2010-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2010-04-01 2010-04-01 false Wash water. 19.328 Section... THE TREASURY LIQUORS DISTILLED SPIRITS PLANTS Production Chemical By-Products § 19.328 Wash water. Water used in washing chemicals to remove spirits therefrom may be run into a wash tank or a distilling...

  3. CY2003 RCRA GROUNDWATER MONITORING WELL SUMMARY REPORT

    International Nuclear Information System (INIS)

    MARTINEZ, C.R.

    2003-01-01

    This report describes the calendar year (CY) 2003 field activities associated with the installation of two new groundwater monitoring wells in the A-AX Waste Management Area (WMA) and four groundwater monitoring wells in WMA C in the 200 East Area of the Hanford Nuclear Reservation. All six wells were installed by Fluor Hanford Inc. (FH) for CH2M Hill Hanford Group, Inc. (CHG) in support of Draft Hanford Facility Agreement and Consent Order (Tri-Party Agreement) M-24-00 milestones and ''Resource Conservation and Recovery Act of 1976'' (RCRA) groundwater monitoring requirements. Drilling data for the six wells are summarized in Table 1

  4. Coagulation-flocculation process applied to wastewaters generated in hydrocarbon-contaminated soil washing

    International Nuclear Information System (INIS)

    Torres, L. g.; Belloc, C.; Iturbe, R.; Bandala, E.

    2009-01-01

    A wastewater produced in the contaminated soil washing was treated by means of coagulation-flocculation (CF) process. the wastewater treatment in this work continued petroleum hydrocarbons, a surfactant, i. e., sodium dodecyl sulphate (SDS) as well as salts, humic acids and other constituents that were lixiviated rom the soil during the washing process. The aim of this work was to develop a process for treating the wastewaters generated when washing hydrocarbon-contaminated soils in such a way that it could be recycled to the washing process, and at the end of the cleaning up, the waters could be disposed properly. (Author)

  5. Washing scaling of GeneChip microarray expression

    Directory of Open Access Journals (Sweden)

    Krohn Knut

    2010-05-01

    Full Text Available Abstract Background Post-hybridization washing is an essential part of microarray experiments. Both the quality of the experimental washing protocol and adequate consideration of washing in intensity calibration ultimately affect the quality of the expression estimates extracted from the microarray intensities. Results We conducted experiments on GeneChip microarrays with altered protocols for washing, scanning and staining to study the probe-level intensity changes as a function of the number of washing cycles. For calibration and analysis of the intensity data we make use of the 'hook' method which allows intensity contributions due to non-specific and specific hybridization of perfect match (PM and mismatch (MM probes to be disentangled in a sequence specific manner. On average, washing according to the standard protocol removes about 90% of the non-specific background and about 30-50% and less than 10% of the specific targets from the MM and PM, respectively. Analysis of the washing kinetics shows that the signal-to-noise ratio doubles roughly every ten stringent washing cycles. Washing can be characterized by time-dependent rate constants which reflect the heterogeneous character of target binding to microarray probes. We propose an empirical washing function which estimates the survival of probe bound targets. It depends on the intensity contribution due to specific and non-specific hybridization per probe which can be estimated for each probe using existing methods. The washing function allows probe intensities to be calibrated for the effect of washing. On a relative scale, proper calibration for washing markedly increases expression measures, especially in the limit of small and large values. Conclusions Washing is among the factors which potentially distort expression measures. The proposed first-order correction method allows direct implementation in existing calibration algorithms for microarray data. We provide an experimental

  6. Remediation of cadmium-contaminated paddy soils by washing with calcium chloride: Verification of on-site washing

    International Nuclear Information System (INIS)

    Makino, Tomoyuki; Kamiya, Takashi; Takano, Hiroyuki; Itou, Tadashi; Sekiya, Naoki; Sasaki, Kouta; Maejima, Yuji; Sugahara, Kazuo

    2007-01-01

    We developed a new, three-step soil-wash method to remediate Cd-contaminated paddy fields. The method comprises (1) chemically washing the field soil with a CaCl 2 solution; (2) washing the treated soil with water to eliminate residual Cd and CaCl 2 ; and (3) on-site treatment of wastewater using a portable wastewater treatment system. Cd concentrations in the treated water were below Japan's environmental quality standard (0.01 mg Cd L -1 ), and the removal of Cd from the exchangeable fraction was 55% and from the acid-soluble fraction 15%. While soil fertility properties were affected by the soil washing, adverse effects were not crucial and could be corrected. The washing had no affect on rice growth, and reduced the average Cd concentration in rice grains by about two-thirds compared to a control plot. These results confirmed the effectiveness of the soil-wash method in remediating Cd-contaminated paddy fields. - In situ soil washing in a paddy field using an on-site wastewater treatment system resulted in an effective decrease of Cd in soil and rice grains without affecting rice yield

  7. Washing method of filter

    International Nuclear Information System (INIS)

    Izumidani, Masakiyo; Tanno, Kazuo.

    1978-01-01

    Purpose: To enable automatic filter operation and facilitate back-washing operation by back-washing filters used in a bwr nuclear power plant utilizing an exhaust gas from a ventilator or air conditioner. Method: Exhaust gas from an exhaust pipe of an ventilator or air conditioner is pressurized in a compressor and then introduced in a back-washing gas tank. Then, the exhaust gas pressurized to a predetermined pressure is blown from the inside to the outside of a filter to thereby separate impurities collected on the filter elements and introduce them to a waste tank. (Furukawa, Y.)

  8. Distillery spent wash: Treatment technologies and potential applications

    International Nuclear Information System (INIS)

    Mohana, Sarayu; Acharya, Bhavik K.; Madamwar, Datta

    2009-01-01

    Distillery spent wash is the unwanted residual liquid waste generated during alcohol production and pollution caused by it is one of the most critical environmental issue. Despite standards imposed on effluent quality, untreated or partially treated effluent very often finds access to watercourses. The distillery wastewater with its characteristic unpleasant odor poses a serious threat to the water quality in several regions around the globe. The ever-increasing generation of distillery spent wash on the one hand and stringent legislative regulations of its disposal on the other has stimulated the need for developing new technologies to process this effluent efficiently and economically. A number of clean up technologies have been put into practice and novel bioremediation approaches for treatment of distillery spent wash are being worked out. Potential microbial (anaerobic and aerobic) as well as physicochemical processes as feasible remediation technologies to combat environmental pollution are being explored. An emerging field in distillery waste management is exploiting its nutritive potential for production of various high value compounds. This review presents an overview of the pollution problems caused by distillery spent wash, the technologies employed globally for its treatment and its alternative use in various biotechnological sectors

  9. Transport of phosphorus, wash load and suspended sediment in the River Varde A in southwest Jutland, Denmark

    DEFF Research Database (Denmark)

    Thodsen, Hans; Hasholt, Bent; Pejrup, Morten

    2004-01-01

    Total phosphorus (TP) concentrations, suspended sediment concentrations (SSC) and wash load have been measured at three river monitoring stations in the River Varde Angstrom system since 1998. This provides the possibility of studying the link between SSC and wash load and concentrations of TP...... at the end of a small impoundment. Transport rates at the upstream stations were 57% higher for suspended sediment and 27% higher for wash load than at the downstream station, while transport of TP was the same. This indicates that phosphorus is transported adhered to the finest grain size fractions that do...

  10. Remediation of cadmium contamination in paddy soils by washing with chemicals: Selection of washing chemicals

    International Nuclear Information System (INIS)

    Makino, Tomoyuki; Sugahara, Kazuo; Sakurai, Yasuhiro; Takano, Hiroyuki; Kamiya, Takashi; Sasaki, Kouta; Itou, Tadashi; Sekiya, Naoki

    2006-01-01

    The efficiencies of neutral salts, strong acids, and chelates were tested for extracting cadmium (Cd) from three paddy soils. The higher the selectivity of the cations of the added neutral salts toward soil adsorption sites, the lower the pH in the extracts and the more soil Cd could be extracted. In addition, soil carbon and nitrogen contents and mineral composition were closely associated with the amount of Cd extracted. Calcium chloride and iron(III) chloride were selected as wash chemicals to restore Cd-contaminated paddy soils in situ. Washing with calcium chloride led to the formation of Cd chloride complexes, enhancing Cd extraction from the soils. The washing also substantially decreased soil levels of exchangeable and acid-soluble Cd, which are the major forms of bioavailable Cd for rice (Oryza sativa L.). The optimum conditions for in situ soil washing were also determined for calcium chloride. - Calcium chloride and iron(III) chloride were useful for the in situ washing of Cd-contaminated paddy soils

  11. Monitoring of psychological well-being in outpatients with diabetes

    DEFF Research Database (Denmark)

    Pouwer, F; Snoek, Frank J; Van Der Ploeg, Henk M

    2001-01-01

    OBJECTIVE: To investigate whether monitoring and discussing psychological well-being in outpatients with diabetes improves mood, glycemic control, and the patient's evaluation of the quality of diabetes care. RESEARCH DESIGN AND METHODS: This study was a randomized controlled trial of 461...... outpatients with diabetes who were randomly assigned to standard care or to the monitoring condition. In the latter group, the diabetes nurse specialist assessed and discussed psychological well-being with the patient (with an interval of 6 months) in addition to standard care. The computerized Well...... nurse. The two groups did not differ for HbA(1c) or in their overall evaluation of the quality of diabetes care. In the monitoring condition, significantly more subjects were referred to the psychologist. CONCLUSIONS: Monitoring and discussing psychological well-being as part of routine diabetes...

  12. Alternative Antimicrobial Commercial Egg Washing Procedures.

    Science.gov (United States)

    Hudson, Lauren K; Harrison, Mark A; Berrang, Mark E; Jones, Deana R

    2016-07-01

    Commercial table eggs are washed prior to packaging. Standard wash procedures use an alkaline pH and warm water. If a cool water method could be developed that would still provide a microbiologically safe egg, the industry may save energy costs associated with water heating. Four wash procedures were evaluated for Salmonella reduction: pH 11 at 48.9°C (industry standard), pH 11 at ambient temperature (∼20°C), pH 6 at 48.9°C, and pH 6 at ambient temperature. Alkaline washes contained potassium hydroxide-based detergent, while pH 6 washes contained approximately 200 ppm of chlorine and a proprietary chlorine stabilizer (T-128). When eggs were inoculated by immersion in a cell suspension of Salmonella Enteritidis and Salmonella Typhimurium, all treatments resulted in a slight and similar reduction of Salmonella numbers (approximately 0.77 log CFU/ml of shell emulsion reduction). When eggs were inoculated by droplet on the shell surface, Salmonella counts were reduced by approximately 5 log CFU when washed with chlorine plus the chlorine stabilizer at both temperatures and with the alkaline wash at the high temperature. The reductions in Salmonella by these treatments were not significantly (P > 0.05) different from each other but were significantly (P pH 11 warm water wash and may be a viable option to reduce cost, increase shelf life, and slow pathogen growth in and on shell eggs.

  13. Pollutants Characterization of Car Wash Wastewater

    Directory of Open Access Journals (Sweden)

    Hashim Nor Haslina

    2016-01-01

    Full Text Available The huge quantity of water consumed per car during washing cars yields the untreated effluents discharged to the stormwater system. Wastewater samples from snow car wash and two full hand service car wash station were analyzed for pH and the presence of PO43-,TP, O&G, alkalinity, TSS, NO3-, NO2-, COD and surfactant in accordance Standard Method of Water and Wastewater 2012. Two full hand wash service stations and one station of snow foam service were investigated in this study. Amongst the stations, snow foam car wash station indicates the highest concentration of PO43-, TP, O&G, TSS, COD and surfactant with the average value of 10.18 ± 0.87 mg/L, 30.93 ± 0.31 mg/L , 85.00 ± 0.64 mg/L 325.0 ± 0.6 mg/L, 485.0 ± 0.3 mg/L and 54.00 ± 2.50 mg/L as MBAS, respectively. Whereas, in parameters characterization in different stages throughout the car wash process, O&G was found to be the highest in pre soak stage, PO43-, TP, TSS and COD in washing stage and NO3- and NO2- in rinse stage. All parameters were compared to Environmental Quality (Industrial Effluent Regulations, 2009. There is a strong need to study on the characterization of car wash water in order to suggest the suitable treatment need for this type of wastewater.

  14. Soil washing treatability study

    International Nuclear Information System (INIS)

    Krstich, M.

    1995-12-01

    Soil washing was identified as a viable treatment process option for remediating soil at the FEMP Environmental Management Project (FEMP). Little information relative to the specific application and potential effectiveness of the soil washing process exists that applies to the types of soil at the FEMP. To properly evaluate this process option in conjunction with the ongoing FEMP Remedial Investigation/Feasibility Study (RI/FS), a treatability testing program was necessary to provide a foundation for a detailed technical evaluation of the viability of the process. In August 1991, efforts were initiated to develop a work plan and experimental design for investigating the effectiveness of soil washing on FEMP soil. In August 1992, the final Treatability Study Work Plan for Operable Unit 5: Soil Washing (DOE 1992) was issued. This document shall be referenced throughout the remainder of this report as the Treatability Study Work Plan (TSWP). The purpose of this treatability study was to generate data to support initial screening and the detailed analysis of alternatives for the Operable Unit 5 FS

  15. Overview of JGC soil washing and site stabilization (SWSS) concept

    International Nuclear Information System (INIS)

    Goetsch, S.; Fujimura, Y.; Sauda, K.; Yagi, T.; Suzuki, K.

    1991-01-01

    The JGC Soil Washing and Site Stabilization (SWSS) concept is to wash heavy metal and uranium-contaminated soils using well demonstrated techniques, and to follow that process with its innovative stabilization process, to fix the remaining contaminates within a stable matrix. In addition, the solution used to wash the soil is stripped of contaminates, so that it can be reused. This process reduces the total amount of wastes generated from washing the soil, since not only can the solution be reused, but often the extracted contaminates can be recovered for industrial use. The stabilization portion of the concept is based on a family of proprietary fixing agents which can render the remaining contaminates insoluble. These agents are significantly different from other (generally silicate) agents used for stabilizing contaminated soils in that they appear to bond more strongly to heavy metal contaminants than the silicate-based reagents, resulting in improved leach-rate performance when combined with bentonite or portland cement stabilization

  16. Effect of Disinfectants on Preventing the Cross-Contamination of Pathogens in Fresh Produce Washing Water

    Directory of Open Access Journals (Sweden)

    Jennifer L. Banach

    2015-07-01

    Full Text Available The potential cross-contamination of pathogens between clean and contaminated produce in the washing tank is highly dependent on the water quality. Process wash water disinfectants are applied to maintain the water quality during processing. The review examines the efficacy of process wash water disinfectants during produce processing with the aim to prevent cross-contamination of pathogens. Process wash water disinfection requires short contact times so microorganisms are rapidly inactivated. Free chlorine, chlorine dioxide, ozone, and peracetic acid were considered suitable disinfectants. A disinfectant’s reactivity with the organic matter will determine the disinfectant residual, which is of paramount importance for microbial inactivation and should be monitored in situ. Furthermore, the chemical and worker safety, and the legislative framework will determine the suitability of a disinfection technique. Current research often focuses on produce decontamination and to a lesser extent on preventing cross-contamination. Further research on a sanitizer’s efficacy in the washing water is recommended at the laboratory scale, in particular with experimental designs reflecting industrial conditions. Validation on the industrial scale is warranted to better understand the overall effects of a sanitizer.

  17. Effect of Disinfectants on Preventing the Cross-Contamination of Pathogens in Fresh Produce Washing Water

    Science.gov (United States)

    Banach, Jennifer L.; Sampers, Imca; Van Haute, Sam; van der Fels-Klerx, H.J. (Ine)

    2015-01-01

    The potential cross-contamination of pathogens between clean and contaminated produce in the washing tank is highly dependent on the water quality. Process wash water disinfectants are applied to maintain the water quality during processing. The review examines the efficacy of process wash water disinfectants during produce processing with the aim to prevent cross-contamination of pathogens. Process wash water disinfection requires short contact times so microorganisms are rapidly inactivated. Free chlorine, chlorine dioxide, ozone, and peracetic acid were considered suitable disinfectants. A disinfectant’s reactivity with the organic matter will determine the disinfectant residual, which is of paramount importance for microbial inactivation and should be monitored in situ. Furthermore, the chemical and worker safety, and the legislative framework will determine the suitability of a disinfection technique. Current research often focuses on produce decontamination and to a lesser extent on preventing cross-contamination. Further research on a sanitizer’s efficacy in the washing water is recommended at the laboratory scale, in particular with experimental designs reflecting industrial conditions. Validation on the industrial scale is warranted to better understand the overall effects of a sanitizer. PMID:26213953

  18. 21 CFR 1250.87 - Wash water.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Wash water. 1250.87 Section 1250.87 Food and Drugs... Sanitation Facilities and Conditions on Vessels § 1250.87 Wash water. Where systems installed on vessels for wash water, as defined in § 1250.3(n), do not comply with the requirements of a potable water system...

  19. Counter current decantation washing of HLW sludge

    International Nuclear Information System (INIS)

    Brooke, J.N.; Peterson, R.A.

    1997-01-01

    The Savannah River Site (SRS) has 51 High Level Waste (HLW) tanks with typical dimensions 25.9 meters (85 feet) diameter and 10 meters (33 feet) high. Nearly 114 million liters (30 M gallons) of HLW waste is stored in these tanks in the form of insoluble solids called sludge, crystallized salt called salt cake, and salt solutions. This waste is being converted to waste forms stable for long term storage. In one of the processes, soluble salts are washed from HLW sludge in preparation for vitrification. At present, sludge is batch washed in a waste tank with one or no reuse of the wash water. Sodium hydroxide and sodium nitrite are added to the wash water for tank corrosion protection; the large volumes of spent wash water are recycled to the evaporator system; additional salt cake is produced; and sodium carbonate is formed in the washed sludge during storage by reaction with CO 2 from the air. High costs and operational concerns with the current washing process prompts DOE and WSRC to seek an improved washing method. A new method should take full advantage of the physical/chemical properties of sludge, experience from other technical disciplines, processing rate requirements, inherent process safety, and use of proven processes and equipment. Counter current solids washing is a common process in the minerals processing and chemical industries. Washing circuits can be designed using thickeners, filters or centrifuges. Realizing the special needs of nuclear work and the low processing rates required, a Counter Current Decantation (CCD) circuit is proposed using small thickeners and fluidic pumps

  20. Check experiment of the high pressure water washing technology used to the decommissioning of reactor

    International Nuclear Information System (INIS)

    Han Jianping; Hou Yongming; Fu Yunshan

    2004-01-01

    High pressure water washing technology has been widely applied in the field of the decommissioning of nuclear facilities, and it is used to wash the sump for craft conveyance, the craft workshop, the hermetic sump, and some other nuclear equipment as well. The authors have got a set of technical data correlated with high pressure water washing technology by comparing the situations between the test before and after the washing work. At the same time, authors also improve the technique on some special cases, which made the high pressure water washing technology more perfect in the field of the decommissioning of nuclear facilities. (authors)

  1. Hand Washing: Do's and Dont's

    Science.gov (United States)

    ... hands frequently can help limit the transfer of bacteria, viruses and other microbes. Always wash your hands before: Preparing food or eating Treating wounds or caring for a sick person Inserting or removing contact lenses Always wash your hands after: Preparing food Using ...

  2. Hand washing promotion for preventing diarrhoea

    Science.gov (United States)

    Ejemot-Nwadiaro, Regina I; Ehiri, John E; Arikpo, Dachi; Meremikwu, Martin M; Critchley, Julia A

    2015-01-01

    Background Diarrhoea accounts for 1.8 million deaths in children in low- and middle-income countries (LMICs). One of the identified strategies to prevent diarrhoea is hand washing. Objectives To assess the effects of hand washing promotion interventions on diarrhoeal episodes in children and adults. Search methods We searched the Cochrane Infectious Diseases Group Specialized Register (27 May 2015); CENTRAL (published in the Cochrane Library 2015, Issue 5); MEDLINE (1966 to 27 May 2015); EMBASE (1974 to 27 May 2015); LILACS (1982 to 27 May 2015); PsycINFO (1967 to 27 May 2015); Science Citation Index and Social Science Citation Index (1981 to 27 May 2015); ERIC (1966 to 27 May 2015); SPECTR (2000 to 27 May 2015); Bibliomap (1990 to 27 May 2015); RoRe, The Grey Literature (2002 to 27 May 2015); World Health Organization (WHO) International Clinical Trial Registry Platform (ICTRP), metaRegister of Controlled Trials (mRCT), and reference lists of articles up to 27 May 2015. We also contacted researchers and organizations in the field. Selection criteria Individually randomized controlled trials (RCTs) and cluster-RCTs that compared the effects of hand washing interventions on diarrhoea episodes in children and adults with no intervention. Data collection and analysis Three review authors independently assessed trial eligibility, extracted data, and assessed risk of bias. We stratified the analyses for child day-care centres or schools, community, and hospital-based settings. Where appropriate, incidence rate ratios (IRR) were pooled using the generic inverse variance method and random-effects model with 95% confidence intervals (CIs). We used the GRADE approach to assess the quality of evidence. Main results We included 22 RCTs: 12 trials from child day-care centres or schools in mainly high-income countries (54,006 participants), nine community-based trials in LMICs (15,303 participants), and one hospital-based trial among people with acquired immune deficiency

  3. Environmental diagnosis of the washing machine motor

    DEFF Research Database (Denmark)

    Erichsen, Hanne K. Linnet

    1997-01-01

    An environmental diagnosis of the washing machine focusing on the motor is performed. The goal of the diagnosis is to designate environmental focus points in the product. The LCA of the washing machine showed impact potentials from the life cycle of the product (see: LCA of a washing machine). Th...... up 2%, Manually disassembling and recycling of metals, Reuse of motor in a new washing machine, aluminium wire instead of copper wire in the motor....

  4. May car washing represent a risk for Legionella infection?

    Science.gov (United States)

    Baldovin, T; Pierobon, A; Bertoncello, C; Destefani, E; Gennari, M; Stano, A; Baldo, V

    2018-01-01

    Legionella is a ubiquitous Gram-negative bacterium naturally found in aquatic environments. It can pose a health problem when it grows and spreads in man-made water systems. Legionella pneumophila is the most common cause of Legionnaires' disease nowadays, a community-acquired pneumonia with pulmonary symptoms and chest radiography no different from any other form of infectious pneumonia. Legionella monitoring is important for public health reasons, including the identification of unusual environmental sources of Legionella. We report two cases of Legionnaires' disease associated with two different car wash installations in the province of Vicenza, in the Veneto region, northeastern Italy. Patients were not employees of the car wash installations, but users of the service. In both cases, Legionella antigen was detected in urine using the Alere BinaxNOW® Legionella Urinary Antigen, and Legionella antibodies were detected in serum using SERION ELISA classic Legionella pneumophila 1-7 IgG and IgM. Water samples were also analyzed as part of the surveillance program for Legionella prevention and control in compliance with the Italian guidelines. Both patients had clinical symptoms and chest radiography compatible with pneumonia, and only one of them had diabetes as a risk factor. Legionella urinary antigen and serological test on serum samples were positive for Legionella in both patients, even if much slighter in the case A due to the retrospective serological investigation performed a year later the episode and after the second clinical case occurred in the same district. The environmental investigations highlighted two different car wash plants as potential source of infection. A certified company using shock hyperchlorination was asked to disinfect the two plants and, subsequently, control samples resulted negative for Legionella pneumophila. Any water source producing aerosols should be considered at risk for the transmission of Legionella bacteria, including car

  5. Radionuclide content of Las Vegas wash sediments

    International Nuclear Information System (INIS)

    Rudin, M.J.; Meyers, A.M.; Johnson, W.H.

    1996-01-01

    The Las Vegas Wash is an excavated waterway channel which drains all surface water and effluent discharge from sewage-treatment facilities from the greater Las Vegas Metropolitan Area to Lake Mead. Runoff and erosion processes are expected to transport man-made radioactivity that was deposited over the past several decades in the Las Vegas Valley. Additionally, radionuclides disposed of via the city's sanitary system are expected to accumulate in the Wash sediments. Fine and coarse sediment samples were collected at 100 m intervals and analyzed to determine the distribution of alpha- and gamma-emitting radionuclides in the lower 5,500 in of the Las Vegas Wash. Results indicate little accumulation of long-lived fission products in upstream Wash sediments. However, trace amounts of fission products measured in downstream sediments suggest the resuspension and transport of radioactive particulate matter within the Wash. Levels of naturally-occurring radionuclides found in Wash sediments were found to be consistent with levels typically found in southeast Nevada soils

  6. Wash water waste pretreatment system study

    Science.gov (United States)

    1976-01-01

    The use of real wash water had no adverse effect on soap removal when an Olive Leaf soap based system was used; 96 percent of the soap was removed using ferric chloride. Numerous chemical agents were evaluated as antifoams for synthetic wash water. Wash water surfactants used included Olive Leaf Soap, Ivory Soap, Neutrogena and Neutrogena Rain Bath Gel, Alipal CO-436, Aerosol 18, Miranol JEM, Palmeto, and Aerosol MA-80. For each type of soapy wash water evaluated, at least one antifoam capable of causing nonpersistent foam was identified. In general, the silicones and the heavy metal ions (i.e., ferric, aluminum, etc.) were the most effective antifoams. Required dosage was in the range of 50 to 200 ppm.

  7. Enhanced sludge washing evaluation plan

    Energy Technology Data Exchange (ETDEWEB)

    Jensen, R.D.

    1994-09-01

    The Tank Waste Remediation System (TWRS) Program mission is to store, treat, and immobilize highly radioactive Hanford Site waste (current and future tank waste and the strontium/cesium capsules) in an environmentally sound, safe, and cost-effective manner. The scope of the TWRS Waste Pretreatment Program is to treat tank waste and separate that waste into HLW and LLW fractions and provide additional treatment as required to feed LLW and HLW immobilization facilities. Enhanced sludge washing was chosen as the baseline process for separating Hanford tank waste sludge. Section 1.0 briefly discusses the purpose of the evaluation plan and provides the background that led to the choice of enhanced sludge washing as the baseline process. Section 2.0 provides a brief summary of the evaluation plan details. Section 3.0 discusses, in some detail, the technical work planned to support the evaluation of enhanced sludge washing. Section 4.0 briefly discusses the potential important of policy issues to the evaluation. Section 5.0 discusses the methodology to be used in the evaluation process. Section 6.0 summarizes the milestones that have been defined to complete the enhanced sludge washing evaluation and provides a summary schedule to evaluate the performance of enhanced sludge washing. References are identified in Section 7.0, and additional schedule and milestone information is provided in the appendices.

  8. Enhanced sludge washing evaluation plan

    International Nuclear Information System (INIS)

    Jensen, R.D.

    1994-09-01

    The Tank Waste Remediation System (TWRS) Program mission is to store, treat, and immobilize highly radioactive Hanford Site waste (current and future tank waste and the strontium/cesium capsules) in an environmentally sound, safe, and cost-effective manner. The scope of the TWRS Waste Pretreatment Program is to treat tank waste and separate that waste into HLW and LLW fractions and provide additional treatment as required to feed LLW and HLW immobilization facilities. Enhanced sludge washing was chosen as the baseline process for separating Hanford tank waste sludge. Section 1.0 briefly discusses the purpose of the evaluation plan and provides the background that led to the choice of enhanced sludge washing as the baseline process. Section 2.0 provides a brief summary of the evaluation plan details. Section 3.0 discusses, in some detail, the technical work planned to support the evaluation of enhanced sludge washing. Section 4.0 briefly discusses the potential important of policy issues to the evaluation. Section 5.0 discusses the methodology to be used in the evaluation process. Section 6.0 summarizes the milestones that have been defined to complete the enhanced sludge washing evaluation and provides a summary schedule to evaluate the performance of enhanced sludge washing. References are identified in Section 7.0, and additional schedule and milestone information is provided in the appendices

  9. 30 CFR 206.459 - Allocation of washed coal.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 2 2010-07-01 2010-07-01 false Allocation of washed coal. 206.459 Section 206... MANAGEMENT PRODUCT VALUATION Indian Coal § 206.459 Allocation of washed coal. (a) When coal is subjected to washing, the washed coal must be allocated to the leases from which it was extracted. (b) When the net...

  10. 30 CFR 206.260 - Allocation of washed coal.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 2 2010-07-01 2010-07-01 false Allocation of washed coal. 206.260 Section 206... MANAGEMENT PRODUCT VALUATION Federal Coal § 206.260 Allocation of washed coal. (a) When coal is subjected to washing, the washed coal must be allocated to the leases from which it was extracted. (b) When the net...

  11. Eye wash water flow direction study: an evaluation of the effectiveness of eye wash devices with opposite directional water flow.

    Science.gov (United States)

    Fogt, Jennifer S; Jones-Jordan, Lisa A; Barr, Joseph T

    2018-01-01

    New designs of eye wash stations have been developed in which the direction of water flow from the fountain has been reversed, with two water streams originating nasally in both eyes and flowing toward the temporal side of each eye. No study has been done to determine the ideal direction of water flow coming from the eye wash in relation to the eye. Ophthalmic eye examinations were conducted before and after the use of two eye wash stations with opposite water flow directionality. Fluorescein was instilled in both eyes before using an eye wash to measure the effectiveness of the water flow. Subjects were surveyed upon their experiences using the eye washes. Ophthalmic examination found no significant difference in the efficacy of the eye washes with nasal-to-temporal water flow when compared to temporal-to-nasal water flow direction.

  12. Rapid washing of filter paper discs in a solid-phase radioimmunoassay with a constant flow washing device

    International Nuclear Information System (INIS)

    Kemeny, D.M.; West, F.B.

    1982-01-01

    A machine has been developed for the rapid washing of the cellulose filter paper discs that are used in a number of radioimmunoassays. The machine is simple in design, easy to use, and is capable of washing 96 filter paper discs simultaneously. The efficiency of the machine is demonstrated by a RAST assay for measuring IgE antibodies to the venom. Time taken to wash the discs was reduced 3-fold without loss of sensitivity or reproducibility. (Auth.)

  13. Monitoring drinking water, sanitation, and hygiene in non-household settings: Priorities for policy and practice.

    Science.gov (United States)

    Cronk, Ryan; Slaymaker, Tom; Bartram, Jamie

    2015-11-01

    Inadequate drinking water, sanitation, and hygiene (WaSH) in non-household settings, such as schools, health care facilities, and workplaces impacts the health, education, welfare, and productivity of populations, particularly in low and middle-income countries. There is limited knowledge on the status of WaSH in such settings. To address this gap, we reviewed international standards, international and national actors, and monitoring initiatives; developed the first typology of non-household settings; and assessed the viability of monitoring. Based on setting characteristics, non-household settings include six types: schools, health care facilities, workplaces, temporary use settings, mass gatherings, and dislocated populations. To-date national governments and international actors have focused monitoring of non-household settings on schools and health care facilities with comparatively little attention given to other settings such as workplaces and markets. Nationally representative facility surveys and national management information systems are the primary monitoring mechanisms. Data suggest that WaSH coverage is generally poor and often lower than in corresponding household settings. Definitions, indicators, and data sources are underdeveloped and not always comparable between countries. While not all countries monitor non-household settings, examples are available from countries on most continents suggesting that systematic monitoring is achievable. Monitoring WaSH in schools and health care facilities is most viable. Monitoring WaSH in other non-household settings would be viable with: technical support from local and national actors in addition to international organizations such as WHO and UNICEF; national prioritization through policy and financing; and including WaSH indicators into monitoring initiatives to improve cost-effectiveness. International consultations on targets and indicators for global monitoring of WaSH post-2015 identified non

  14. Soil washing

    International Nuclear Information System (INIS)

    Neuman, R.S.; Diel, B.N.; Halpern, Y.

    1992-01-01

    Disposal of soils or sludges contaminated with organic and inorganic compounds is a major problem for environmental remedial activities, hazardous waste generators, and the disposal industry. This paper reports that many of these wastes can be effectively treated utilizing soil washing technology. CWM has been developing soil washing technology over the past few years, with extensive work being conducted on the bench scale. These studies have demonstrated consistently high removal efficiencies (95-99%) for a wide variety of PCB and petroleum hydrocarbon contaminated waste. Recently, a comprehensive study examining the removal of both organic and inorganic contraminants from two different types of surrogate soil matrices was completed. In addition to establishing the range of contaminants that can be removed from soil, a method for surfactant/water separation was evaluated. For example, using a thermal phase separation method, approximately 90% of the surfactant could be recovered from the water

  15. Cross contamination of Escherichia coli O157:H7 between lettuce and wash water during home-scale washing.

    Science.gov (United States)

    Jensen, Dane A; Friedrich, Loretta M; Harris, Linda J; Danyluk, Michelle D; Schaffner, Donald W

    2015-04-01

    Lettuce and leafy greens have been implicated in multiple foodborne disease outbreaks. This study quantifies cross contamination between lettuce pieces in a small-scale home environment. A five-strain cocktail of relevant Escherichia coli O157:H7 strains was used. Bacterial transfer between single inoculated lettuce leaf pieces to 10 non-inoculated lettuce leaf pieces that were washed in a stainless steel bowl of water for 30 s, 1 min, 2 min, and 5 min was quantified. Regardless of washing time, the wash water became contaminated with 90-99% of bacteria originally present on the inoculated lettuce leaf piece. The E. coli O157:H7 concentration on initially inoculated leaf pieces was reduced ∼ 2 log CFU. Each initially uncontaminated lettuce leaf piece had ∼ 1% of the E. coli O157:H7 from the inoculated lettuce piece transferred to it after washing, with more transfer occurring during the shortest (30 s) and longest (5 min) wash times. In all cases the log percent transfer rates were essentially normally distributed. In all scenarios, most of the E. coli O157:H7 (90-99%) transferred from the inoculated lettuce pieces to the wash water. Washing with plain tap water reduces levels of E. coli O157:H7 on the inoculated lettuce leaf pieces, but also spreads contamination to previously uncontaminated leaf pieces. Copyright © 2014 Elsevier Ltd. All rights reserved.

  16. Washing enhanced electrokinetic remediation for removal cadmium from real contaminated soil

    International Nuclear Information System (INIS)

    Giannis, Apostolos; Gidarakos, Evangelos

    2005-01-01

    The main objective of this study is to evaluate the combination of electrokinetic remediation and soil washing technology in order to remove cadmium from contaminated soil. This paper presents the results of an experimental research undertaken to evaluate different washing and purging solutions to enhance the removal of cadmium from a real contaminated soil during electrokinetic remediation. Two different experimental modules were applied in the laboratory. Soil was saturated with tap water, while acetic and hydrochloric acids, as well as ethylenediaminetetraacetic acid (EDTA) were used as purging solutions in the first module. Results show that there was a decrease of cadmium concentration near anode, but a significant increase in the middle of the cell, due to the increasing pH. Citric, nitric and acetic acids were used for soil washing and purging solutions in the second module. In this case, an 85% reduction of cadmium concentration was achieved. Therefore, results indicate that soil pH and washing solutions are the most important factors in governing the dissolution and/or desorption of Cd in a soil system under electrical fields

  17. Stability and Wash Resistance of Local Made Mosquito Bednets and Detergents Treated with Pyrethroids against Anopheles stephensi

    Directory of Open Access Journals (Sweden)

    H Vatandoost

    2009-06-01

    Full Text Available Background: We aimed to evaluate different fibres of bednets impregnated with various pyrethroids. The stability of insecticide on the bednet was measured using different methods of washings as well as local made detergents.Methods: The entire test was carried out according to the WHO-recommended methods. In addition, the impact of the numbers of washes on the stability of the insecticides was determined. Permethrin 10% (EC, deltamethrin 10% (SC, lambdacyhalothrin 2.5% (CS and cyfluthrin 5% (EW were used at the recommended dosages. Three different lo­cal detergents were used. Two kinds of washing methods (shaking, no shaking were used and in each method four kinds of washings, i.e. no wash, one wash, two washes and three washes was done. The main malaria vectors, Anophe­les stephensi, which is susceptible to all insecticides (BEECH strain, was tested with impregnated bednets in 3 minutes exposure time and the mortality was measured after 24 hours recovery period. Knock-down was measured as well using appropriate statistical methods.Results: Lambdacyhalothrin has saved its insecticidal impact after being washed, whereas, deltamethrin has lost its activ­ity faster than other insecticides. Tow other insecticides had moderate effect. Golnar soap detergent has least ef­fect on the durability of insecticides, but the Shoma had the most. Whit increasing  the times of washing, insecticidal ef­fects was decreased , but shaking had no influence on the decreasing  of the quality of insecticidal impact.Conclusion: Results will be useful for local people who wish to use pyrethroid-impregnated bednets with their own lo­cal made detergent and bednets. 

  18. Wash functions downstream of Rho1 GTPase in a subset of Drosophila immune cell developmental migrations

    Science.gov (United States)

    Verboon, Jeffrey M.; Rahe, Travis K.; Rodriguez-Mesa, Evelyn; Parkhurst, Susan M.

    2015-01-01

    Drosophila immune cells, the hemocytes, undergo four stereotypical developmental migrations to populate the embryo, where they provide immune reconnoitering, as well as a number of non–immune-related functions necessary for proper embryogenesis. Here, we describe a role for Rho1 in one of these developmental migrations in which posteriorly located hemocytes migrate toward the head. This migration requires the interaction of Rho1 with its downstream effector Wash, a Wiskott–Aldrich syndrome family protein. Both Wash knockdown and a Rho1 transgene harboring a mutation that prevents Wash binding exhibit the same developmental migratory defect as Rho1 knockdown. Wash activates the Arp2/3 complex, whose activity is needed for this migration, whereas members of the WASH regulatory complex (SWIP, Strumpellin, and CCDC53) are not. Our results suggest a WASH complex–independent signaling pathway to regulate the cytoskeleton during a subset of hemocyte developmental migrations. PMID:25739458

  19. Detecting wash trade in the financial market

    OpenAIRE

    Cao, Yi; Li, Yuhua; Coleman, Sonya; Belatreche, Ammar; McGinnity, T. M.

    2014-01-01

    Wash trade refers to the activities of traders who utilise deliberately designed collusive transactions to increase the trading volumes for creating active market impression. Wash trade can be damaging to the proper functioning and integrity of capital markets. Existing work focuses on collusive clique detections based on certain assumptions of trading behaviours. Effective approaches for analysing and detecting wash trade in a real-life market have yet to be developed. T...

  20. Washing of waste prior to landfilling.

    Science.gov (United States)

    Cossu, Raffaello; Lai, Tiziana

    2012-05-01

    The main impact produced by landfills is represented by the release of leachate emissions. Waste washing treatment has been investigated to evaluate its efficiency in reducing the waste leaching fraction prior to landfilling. The results of laboratory-scale washing tests applied to several significant residues from integrated management of solid waste are presented in this study, specifically: non-recyclable plastics from source separation, mechanical-biological treated municipal solid waste and a special waste, automotive shredded residues. Results obtained demonstrate that washing treatment contributes towards combating the environmental impacts of raw wastes. Accordingly, a leachate production model was applied, leading to the consideration that the concentrations of chemical oxygen demand (COD) and total Kjeldahl nitrogen (TKN), parameters of fundamental importance in the characterization of landfill leachate, from a landfill containing washed wastes, are comparable to those that would only be reached between 90 and 220years later in the presence of raw wastes. The findings obtained demonstrated that washing of waste may represent an effective means of reducing the leachable fraction resulting in a consequent decrease in landfill emissions. Further studies on pilot scale are needed to assess the potential for full-scale application of this treatment. Copyright © 2012 Elsevier Ltd. All rights reserved.

  1. Monitoring well inspection and maintenance plan Y-12 Plant, Oak Ridge, Tennessee (revised)

    International Nuclear Information System (INIS)

    1996-09-01

    Inspection and maintenance of groundwater monitoring wells is a primary element of the Oak Ridge Y-12 Plant Groundwater Protection Program (GWPP). This document is the revised groundwater monitoring well inspection and maintenance plan for the U.S. Department of Energy (DOE) Y-12 Plant in Oak Ridge, Tennessee. The plan provides a systematic program for: (1) inspecting the physical condition of monitoring wells at the Y-12 Plant and (2) identifying maintenance needs that will extend the life of each well and ensure that representative groundwater quality samples and hydrologic data are collected from the wells. Original documentation for the Y-12 Plant GWPP monitoring well inspection and maintenance program was provided in HSW, Inc. 1991a. The original revision of the plan specified that only a Monitoring Well Inspection/Maintenance Summary need be updated and reissued each year. Rapid growth of the monitoring well network and changing regulatory requirements have resulted in constant changes to the status of wells (active or inactive) listed on the Monitoring Well Inspection/Maintenance Summary. As a result, a new mechanism to track the status of monitoring wells has been developed and the plan revised to formalize the new business practices. These changes are detailed in Sections 2.4 and 2.5

  2. A comparison of groundwater investigation using temporary points versus permanent monitoring wells

    International Nuclear Information System (INIS)

    Thompson, N.T.

    1994-01-01

    Groundwater investigation within the environmental industry is most often conducted using permanent monitoring wells. A monitoring well, as the term suggests, is permanent to the extent that it is fixed in place to monitor groundwater quality in its immediate vicinity at any given time over the course of an environmental project. Because monitoring wells are relatively time consuming and expensive to construct, a minimum number of wells is normally installed as part of a single investigation event. The initial information obtained from monitoring wells could also be obtained from temporary groundwater sampling points. Temporary points generally are smaller in diameter than monitoring wells, are installed to provide a one time snap shot of the subsurface, and are removed at the completion of the investigation. Since temporary points are usually easier to install and less expensive than monitoring wells, more temporary points can be installed over a single investigation event and can often reduce or eliminate subsequent assessment(s). A brief discussion of temporary point installation and sampling is offered before considering two case studies within the context of the above advantages to temporary point installation. One case study focuses on vertical delineation of dissolved petroleum hydrocarbons, while the second case study discusses lateral delineation of light nonaqueous phase liquid (LNAPL)

  3. Wärtsilä turbocharger wash and dew point controller integration

    OpenAIRE

    Perälä, Antti

    2013-01-01

    There are two separate control cabinets used in Wärtsilä marine solutions, Turbocharger Wash Control and the Dew Point Control. The cabinets contain similar PLCs with I/O-cards needed in the system and touch screen for monitoring and controlling purposes. The purpose of the thesis was to find and implement a solution for integration of the control cabinets. The advantages of the integration are savings in material, space in the engine room and amount of work. The aim of the project was to cre...

  4. PASSIVE SAMPLING OF GROUND WATER MONITORING WELLS WITHOUT PURGING MULTILEVEL WELL CHEMISTRY AND TRACER DISAPPEARANCE

    Science.gov (United States)

    It is essential that the sampling techniques utilized in groundwater monitoring provide data that accurately depicts the water quality of the sampled aquifer in the vicinity of the well. Due to the large amount of monitoring activity currently underway in the U.S.A. it is also im...

  5. Monitoring well utility in a heterogeneous DNAPL source zone area: Insights from proximal multilevel sampler wells and sampling capture-zone modelling.

    Science.gov (United States)

    McMillan, Lindsay A; Rivett, Michael O; Wealthall, Gary P; Zeeb, Peter; Dumble, Peter

    2018-03-01

    Groundwater-quality assessment at contaminated sites often involves the use of short-screen (1.5 to 3 m) monitoring wells. However, even over these intervals considerable variation may occur in contaminant concentrations in groundwater adjacent to the well screen. This is especially true in heterogeneous dense non-aqueous phase liquid (DNAPL) source zones, where cm-scale contamination variability may call into question the effectiveness of monitoring wells to deliver representative data. The utility of monitoring wells in such settings is evaluated by reference to high-resolution multilevel sampler (MLS) wells located proximally to short-screen wells, together with sampling capture-zone modelling to explore controls upon well sample provenance and sensitivity to monitoring protocols. Field data are analysed from the highly instrumented SABRE research site that contained an old trichloroethene source zone within a shallow alluvial aquifer at a UK industrial facility. With increased purging, monitoring-well samples tend to a flow-weighted average concentration but may exhibit sensitivity to the implemented protocol and degree of purging. Formation heterogeneity adjacent to the well-screen particularly, alongside pump-intake position and water level, influence this sensitivity. Purging of low volumes is vulnerable to poor reproducibility arising from concentration variability predicted over the initial 1 to 2 screen volumes purged. Marked heterogeneity may also result in limited long-term sample concentration stabilization. Development of bespoke monitoring protocols, that consider screen volumes purged, alongside water-quality indicator parameter stabilization, is recommended to validate and reduce uncertainty when interpreting monitoring-well data within source zone areas. Generalised recommendations on monitoring well based protocols are also developed. A key monitoring well utility is their proportionately greater sample draw from permeable horizons constituting

  6. Monitoring well utility in a heterogeneous DNAPL source zone area: Insights from proximal multilevel sampler wells and sampling capture-zone modelling

    Science.gov (United States)

    McMillan, Lindsay A.; Rivett, Michael O.; Wealthall, Gary P.; Zeeb, Peter; Dumble, Peter

    2018-03-01

    Groundwater-quality assessment at contaminated sites often involves the use of short-screen (1.5 to 3 m) monitoring wells. However, even over these intervals considerable variation may occur in contaminant concentrations in groundwater adjacent to the well screen. This is especially true in heterogeneous dense non-aqueous phase liquid (DNAPL) source zones, where cm-scale contamination variability may call into question the effectiveness of monitoring wells to deliver representative data. The utility of monitoring wells in such settings is evaluated by reference to high-resolution multilevel sampler (MLS) wells located proximally to short-screen wells, together with sampling capture-zone modelling to explore controls upon well sample provenance and sensitivity to monitoring protocols. Field data are analysed from the highly instrumented SABRE research site that contained an old trichloroethene source zone within a shallow alluvial aquifer at a UK industrial facility. With increased purging, monitoring-well samples tend to a flow-weighted average concentration but may exhibit sensitivity to the implemented protocol and degree of purging. Formation heterogeneity adjacent to the well-screen particularly, alongside pump-intake position and water level, influence this sensitivity. Purging of low volumes is vulnerable to poor reproducibility arising from concentration variability predicted over the initial 1 to 2 screen volumes purged. Marked heterogeneity may also result in limited long-term sample concentration stabilization. Development of bespoke monitoring protocols, that consider screen volumes purged, alongside water-quality indicator parameter stabilization, is recommended to validate and reduce uncertainty when interpreting monitoring-well data within source zone areas. Generalised recommendations on monitoring well based protocols are also developed. A key monitoring well utility is their proportionately greater sample draw from permeable horizons constituting a

  7. Washing effects of limonene on pesticide residues in green peppers.

    Science.gov (United States)

    Lu, Hai-Yan; Shen, Yan; Sun, Xing; Zhu, Hong; Liu, Xian-Jin

    2013-09-01

    The presence of pesticide residues in food has caused much concern. The low health risks and environmental impacts of limonene make it a very interesting solvent for use in green chemistry. Washing effects of limonene on pesticide residues of methyl chlorpyrifos, chlorothalonil, chlorpyrifos, fenpropathrin and deltamethrin were investigated in green pepper. Results showed that washing with a low concentration of limonene for 5 min (where LOQ is limit of quantitation) caused 53.67%, limonene for 10 min produced 55.90%, limonene for 5 min was the optimal treatment for elimination of pesticide residues in green pepper, considering effect and treatment time as well as cost. © 2013 Society of Chemical Industry.

  8. Anisotropic analysis for seismic sensitivity of groundwater monitoring wells

    Science.gov (United States)

    Pan, Y.; Hsu, K.

    2011-12-01

    Taiwan is located at the boundaries of Eurasian Plate and the Philippine Sea Plate. The movement of plate causes crustal uplift and lateral deformation to lead frequent earthquakes in the vicinity of Taiwan. The change of groundwater level trigged by earthquake has been observed and studied in Taiwan for many years. The change of groundwater may appear in oscillation and step changes. The former is caused by seismic waves. The latter is caused by the volumetric strain and reflects the strain status. Since the setting of groundwater monitoring well is easier and cheaper than the setting of strain gauge, the groundwater measurement may be used as a indication of stress. This research proposes the concept of seismic sensitivity of groundwater monitoring well and apply to DonHer station in Taiwan. Geostatistical method is used to analysis the anisotropy of seismic sensitivity. GIS is used to map the sensitive area of the existing groundwater monitoring well.

  9. Late washing filter cleaning cycle demonstration

    International Nuclear Information System (INIS)

    Meyer, M.L.; McCabe, D.J.

    1992-01-01

    The DWPF Late Washing Facility will filter cesium and potassium tetraphenyl borate (TPB) solids using a Mott sintered metal filter, identical to the filter now used in the In-tank Precipitation Facility. The purpose of the late wash step is primarily to remove the nitrite salts from the slurry prior to delivery to DWPF. Periodic chemical cleaning of the filter will be required, presumably after each batch although the actual required frequency could not be determined on the lab-scale. Minimization of chemical cleaning solution volumes is key to maximizing the attainment of the Late Wash facility. This report summarizes work completed in experiments designed to identify minimum cleaning solution requirements

  10. 33 CFR 157.124 - COW tank washing machines.

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false COW tank washing machines. 157... OIL IN BULK Crude Oil Washing (COW) System on Tank Vessels Design, Equipment, and Installation § 157.124 COW tank washing machines. (a) COW machines must be permanently mounted in each cargo tank. (b...

  11. Hand washing in operating room: a procedural comparison

    Directory of Open Access Journals (Sweden)

    Alessia Stilo

    2016-09-01

    Full Text Available BACKGROUND Hand washing has been considered a measure of personal hygiene for centuries and it is known that an improper hand hygiene by healthcare workers is responsible for about 40% of nosocomial infections. Therefore, surgical hand preparation is a critical element for healthcare safety in order to reduce microbial contamination of  surgical wound in case of non detected break of the gloves. The aim of our study is to evaluate the efficacy three antiseptics: Povi-iodine scrub; EPG (Ethanol, Hydrogen Peroxide, Glycerol, recommended by WHO, and common marseille soap type in a liquid formulation. METHODS It was designed a randomized, double-blind, single-center study conducted in the University Hospital of Messina, from January to June 2013. We asked operators to put the fingertips of their right hand (if not left-handed for one minute on the PCA medium, before washing with the three types of antiseptics, and after washing and drying. Drying was made using sterile gauzes or disposable wipes. Then, we measured the number of colony forming units per mL (CFU/mL and calculated the percentage of microbial load reduction. RESULTS 211 samples have been considered for statistical analysis: in 42 samples, in fact, initial microbial load was lower than after washing. Washing with EPG reduced CFU/ml from  a mean of 38,9 to 4,1 (86,5% reduction, washing with povi-iodine scrub from 59,55 to 12,9 (75,9% reduction and washing with Marseille soap from 47,26 to 12,7 (64,3% reduction. CONCLUSIONS Our study shows that washing with EPG has superior efficacy in CFU reduction. Antiseptic hand washing, however, cannot be considered the only measure to reduce infections: the anomaly of some results (initial microbial load lower than after washing  demonstrates that drying is an essential phase in the presurgical preparation. Therefore, hand hygiene must be part of a more complex strategy of surveillance and control of nosocomial infections

  12. Apparatus for washing out halogens

    Energy Technology Data Exchange (ETDEWEB)

    Pier, M; Hahn, J; Kroenig, W

    1941-03-26

    An apparatus is described for washing out of halogens and the like or liquid halogen compounds from the products, which are formed on pressure hydrogenation or splitting of carbon-containing material in the presence of halogens or halogen compounds, consisting of a washing apparatus installed between the reaction vessel and the hot separator, which is inclined in relatively small space for steam regulation and contains, with the steam, arranged baffles, especially spirals.

  13. Cold or hot wash: Technological choices, cultural change, and their impact on clothes-washing energy use in China

    International Nuclear Information System (INIS)

    Lin, Jiang; Iyer, Maithili

    2007-01-01

    Usage pattern of clothes washing (and clothes washers) are strongly related to local cultural practices. Such practices have led to the development of distinctive clothes-washing technologies in the US, Europe, and Japan. In emerging markets such as China, several types of technologies often co-exist. Some use less energy but more water (the impeller type), and some use more energy but less water (the horizontal axis type). The competition between different technologies is thought to lead to better consumer choices. However, it could also lead to changes in clothes-washing habits-from cold to hot wash, and therefore to much higher energy use. This paper examines the standard development process in China to illustrate that adoption of foreign technologies and technical standards, if not carefully calibrated to the local cultural practices, could have unintended consequences for energy use and environment

  14. Effects of soap-water wash on human epidermal penetration.

    Science.gov (United States)

    Zhu, Hanjiang; Jung, Eui-Chang; Phuong, Christina; Hui, Xiaoying; Maibach, Howard

    2016-08-01

    Skin decontamination is a primary interventional method used to decrease dermal absorption of hazardous contaminants, including chemical warfare agents, pesticides and industrial pollutants. Soap and water wash, the most common and readily available decontamination system, may enhance percutaneous absorption through the "wash-in effect." To understand better the effect of soap-water wash on percutaneous penetration, and provide insight to improving skin decontamination methods, in vitro human epidermal penetration rates of four C(14) -labeled model chemicals (hydroquinone, clonidine, benzoic acid and paraoxon) were assayed using flow-through diffusion cells. Stratum corneum (SC) absorption rates of these chemicals at various hydration levels (0-295% of the dry SC weights) were determined and compared with the results of the epidermal penetration study to clarify the effect of SC hydration on skin permeability. Results showed accelerated penetration curves of benzoic acid and paraoxon after surface wash at 30 min postdosing. Thirty minutes after washing (60 min postdosing), penetration rates of hydroquinone and benzoic acid decreased due to reduced amounts of chemical on the skin surface and in the SC. At the end of the experiment (90 min postdosing), a soap-water wash resulted in lower hydroquinone penetration, greater paraoxon penetration and similar levels of benzoic acid and clonidine penetration compared to penetration levels in the non-wash groups. The observed wash-in effect agrees with the enhancement effect of SC hydration on the SC chemical absorption rate. These results suggest SC hydration derived from surface wash to be one cause of the wash-in effect. Further, the occurrence of a wash-in effect is dependent on chemical identity and elapsed time between exposure and onset of decontamination. By reducing chemical residue quantity on skin surface and in the SC reservoir, the soap-water wash may decrease the total quantity of chemical absorbed in the

  15. Hand washing promotion for preventing diarrhoea.

    Science.gov (United States)

    Ejemot-Nwadiaro, Regina I; Ehiri, John E; Arikpo, Dachi; Meremikwu, Martin M; Critchley, Julia A

    2015-09-03

    Diarrhoea accounts for 1.8 million deaths in children in low- and middle-income countries (LMICs). One of the identified strategies to prevent diarrhoea is hand washing. To assess the effects of hand washing promotion interventions on diarrhoeal episodes in children and adults. We searched the Cochrane Infectious Diseases Group Specialized Register (27 May 2015); CENTRAL (published in the Cochrane Library 2015, Issue 5); MEDLINE (1966 to 27 May 2015); EMBASE (1974 to 27 May 2015); LILACS (1982 to 27 May 2015); PsycINFO (1967 to 27 May 2015); Science Citation Index and Social Science Citation Index (1981 to 27 May 2015); ERIC (1966 to 27 May 2015); SPECTR (2000 to 27 May 2015); Bibliomap (1990 to 27 May 2015); RoRe, The Grey Literature (2002 to 27 May 2015); World Health Organization (WHO) International Clinical Trial Registry Platform (ICTRP), metaRegister of Controlled Trials (mRCT), and reference lists of articles up to 27 May 2015. We also contacted researchers and organizations in the field. Individually randomized controlled trials (RCTs) and cluster-RCTs that compared the effects of hand washing interventions on diarrhoea episodes in children and adults with no intervention. Three review authors independently assessed trial eligibility, extracted data, and assessed risk of bias. We stratified the analyses for child day-care centres or schools, community, and hospital-based settings. Where appropriate, incidence rate ratios (IRR) were pooled using the generic inverse variance method and random-effects model with 95% confidence intervals (CIs). We used the GRADE approach to assess the quality of evidence. We included 22 RCTs: 12 trials from child day-care centres or schools in mainly high-income countries (54,006 participants), nine community-based trials in LMICs (15,303 participants), and one hospital-based trial among people with acquired immune deficiency syndrome (AIDS) (148 participants).Hand washing promotion (education activities, sometimes with

  16. Soil washing technology evaluation

    International Nuclear Information System (INIS)

    Suer, A.

    1995-04-01

    Environmental Restoration Engineering (ERE) continues to review innovative, efficient, and cost effective technologies for SRS soil and/or groundwater remediation. As part of this effort, this technical evaluation provides review and the latest information on the technology for SRS soil remediation. Additional technology evaluation reports will be issued periodically to update these reports. The purpose of this report is to review the soil washing technology and its potential application to SRS soil remediation. To assess whether the Soil Washing technology is a viable option for SRS soil remediation, it is necessary to review the technology/process, technology advantages/limitations, performance, applications, and cost analysis

  17. Nitrogen Monitoring of West Hackberry 117 Cavern Wells

    Energy Technology Data Exchange (ETDEWEB)

    Bettin, Giorgia [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Lord, David L. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2015-02-01

    U.S. Strategic Petroleum Reserve (SPR) oil storage cavern West Hackberry 117 was tested under extended nitrogen monitoring following a successful mechanical integrity test in order to validate a newly developed hydrostatic column model to be used to differentiate between normal "tight" well behavior and small-leak behavior under nitrogen. High resolution wireline pressure and temperature data were collected during the test period and used in conjunction with the hydrostatic column model to predict the nitrogen/oil interface and the pressure along the entire fluid column from the bradenhead flange nominally at ground surface to bottom of brine pool. Results here and for other SPR caverns have shown that wells under long term nitrogen monitoring do not necessarily pressurize with a relative rate (P N2 /P brine) of 1. The theoretical relative pressure rate depends on the well configuration, pressure and the location of the nitrogen-oil interface and varies from well to well. For the case of WH117 the predicted rates were 0.73 for well A and 0.92 for well B. The measured relative pressurization rate for well B was consistent with the model prediction, while well A rate was found to be between 0.58-0.68. A number of possible reasons for the discrepancy between the model and measured rates of well A are possible. These include modeling inaccuracy, measurement inaccuracy or the possibility of the presence of a very small leak (below the latest calculated minimum detectable leak rate).

  18. Monitoring well plugging and abandonment plan, Y-12 Plant, Oak Ridge, Tennessee (revised)

    International Nuclear Information System (INIS)

    1997-05-01

    Plugging and abandonment (P ampersand A) of defunct groundwater monitoring wells is a primary element of the Oak Ridge Y-12 Plant Groundwater Protection Program (GWPP) (AJA Technical Services, Inc. 1996). This document is the revised groundwater monitoring well P ampersand A plan for the U.S. Department of Energy (DOE) Y-12 Plant located in Oak Ridge, Tennessee. This plan describes the systematic approach employed by Y-12 Plant GWPP to identify wells that require P ampersand A, the technical methods employed to perform P ampersand A activities, and administrative requirements. Original documentation for Y-12 Plant GWPP groundwater monitoring well P ampersand A was provided in HSW, Inc. (1991). The original revision of the plan specified that a comprehensive monitoring well P ampersand A was provided in HSW, Inc. (1991). The original revision of the plan specified that a comprehensive monitoring well P ampersand A schedule be maintained. Wells are added to this list by issuance of both a P ampersand A request and a P ampersand A addendum to the schedule. The current Updated Subsurface Data Base includes a single mechanism to track the status of monitoring wells. In addition, rapid growth of the groundwater monitoring network and new regulatory requirements have resulted in constant changes to the status of wells. As a result, a streamlined mechanism to identify and track monitoring wells scheduled for P ampersand A has been developed and the plan revised to formalize the new business practices

  19. Release of synthetic microplastic plastic fibres from domestic washing machines: Effects of fabric type and washing conditions.

    Science.gov (United States)

    Napper, Imogen E; Thompson, Richard C

    2016-11-15

    Washing clothes made from synthetic materials has been identified as a potentially important source of microscopic fibres to the environment. This study examined the release of fibres from polyester, polyester-cotton blend and acrylic fabrics. These fabrics were laundered under various conditions of temperature, detergent and conditioner. Fibres from waste effluent were examined and the mass, abundance and fibre size compared between treatments. Average fibre size ranged between 11.9 and 17.7μm in diameter, and 5.0 and 7.8mm in length. Polyester-cotton fabric consistently shed significantly fewer fibres than either polyester or acrylic. However, fibre release varied according to wash treatment with various complex interactions. We estimate over 700,000 fibres could be released from an average 6kg wash load of acrylic fabric. As fibres have been reported in effluent from sewage treatment plants, our data indicates fibres released by washing of clothing could be an important source of microplastics to aquatic habitats. Copyright © 2016 Elsevier Ltd. All rights reserved.

  20. Data Acquisition for Low-Temperature Geothermal Well Tests and Long-Term Monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Lienau, P J

    1992-03-01

    Groundwater monitoring is an essential part of the development of a low-temperature geothermal field for production and injection wells. State water resource and environmental departments are requiring both geothermal well testing and long-term monitoring as a part of the permitting process for geothermal developments. This report covers water-level measurement methods, instruments used for well testing, geochemical sampling, examples of data acquisition and regulatory mandates on groundwater monitoring.

  1. Data acquisition for low-temperature geothermal well tests and long-term monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Lienau, P.J.

    1992-09-01

    Groundwater monitoring is an essential part of the development of a low-temperature geothermal field for production and injection wells. State water resource and environmental departments are requiring both geothermal well testing and long-term monitoring as a part of the permitting process for geothermal developments. This report covers water-level measurement methods, instruments used for well testing, geochemical sampling, examples of data acquisition and regulatory mandates on groundwater monitoring.

  2. Process for washing electromagnetic filters

    International Nuclear Information System (INIS)

    Guittet, Maurice; Treille, Pierre.

    1980-01-01

    This process concerns the washing of an electro-magnetic filter used, inter alia, for filtering the drain-off waters of nuclear power station steam generators, by means of a washing water used in closed circuit and freed, after each cleaning, of the solids in suspension it contains, by settlement of these solids. This invention enables the volume of water to be evaporated to be divided by 50, thereby providing a solid assurance of better safety, apart from a very significant saving [fr

  3. Soil washing treatability testing for rad-waste material

    International Nuclear Information System (INIS)

    Leis, K.S.; Lear, P.R.

    1997-01-01

    Soil washing treatability testing was successfully completed on soil contaminated with Ra-226 and Th-232. The objective of the soil washing study was to determine if the radiologically contaminated fraction of the soil could be separated from the bulk of the soil material. The cleanup criteria was 38 microm) fraction was allowed to settle and was washed to separate it from the highly contaminated fine (< 38 microm) fraction. The clean coarse fraction comprised 85.7% of the total solids and had less than 15 pCi/g of Ra-226 and Th-232. This material was to be disposed at a RCRA Subtitle D disposal facility. The suspended fines were flocculated and dewatered to minimize the amount of highly contaminated material produced by the soil washing. The dewatered fines would require disposal at a low-level radiological disposal facility. Mass balance calculations were made to determine production rates and chemical and equipment requirements for the full-scale soil washing treatment

  4. The Savannah River Site's Groundwater Monitoring Program 1991 well installation report

    International Nuclear Information System (INIS)

    1992-06-01

    This report is a summary of the well and environmental soil boring information compiled for the groundwater monitoring program of the Environmental Protection Department/Environmental Monitoring Section (EPD/EMS) at the Savannah River Site (SRS) during 1991. It includes discussion of environmental soil borings, surveying, well installations, abandonments, maintenance, and stabilization

  5. Physical properties of cobia (Rachycentron canadum) surimi: effect of washing cycle at different salt concentrations.

    Science.gov (United States)

    Hamzah, N; Sarbon, N M; Amin, A M

    2015-08-01

    This study aimed to determine the effects of 2-5 wash cycles and the addition of tetrasodium pyrophosphate (TSPP) (0 %, 0.05 Surimi% and 0.1 % w/w)-with or without the addition of 0.4 % calcium chloride (CaCl2)-on the physical properties such as texture, colour, expressible moisture and microstructure of Cobia (Rachycentron canadum) surimi gel. The highest breaking force (484.85 g) was obtained with the addition 0.1 % TSPP alone on the fifth wash. However, a combination of 0.1 and 0.4 % CaCl2 in surimi gels at wash cycle 5 resulted in the highest degree of whiteness (86.8 %), as well as total expressible moisture (2.785 %) and deformation (17.11 mm). The highest surimi gel strength (6,923 g.mm) was obtained after three wash cycles with the addition of 0.1 % TSPP +0.4 % CaCl2. The physical properties of Cobia fish surimi gels were affected by the number of wash cycles and treatments with TSPP and CaCl2.

  6. Irreversible Wash Aid Additive for Cesium Mitigation: WARRP Demonstration

    Energy Technology Data Exchange (ETDEWEB)

    Kaminski, Michael [Argonne National Lab. (ANL), Argonne, IL (United States)

    2015-01-01

    This activity demonstrated, on a practical scale, the primary unit operations for building a containment structure for radioactive wash waters, washing down a hypothetically radioactively contaminated vehicle, collecting the hypothetically radioactive slurry waste water, filtering the hypothetically radioactive wash waters, disassembling the containment, and transporting the materials for final disposition.

  7. Ultrafiltration to reuse laundering wash water

    DEFF Research Database (Denmark)

    Giagnorio, Mattia; Søtoft, Lene Fjerbæk; Tiraferri, Alberto

    2017-01-01

    Laundering industry consumes and discharges large amounts of water and surfactants, and the demand of surface active agents used for washing is increasing worldwide. Some of these substances are considered contaminants of emerging concern, as they persist in the environment. This work aimed...... at evaluating the feasibility of ultrafiltration as a method to treat the wash wastewater and possibly reuse the surfactant-rich permeate stream in laundry facilities. In particular, evaluation of surfactant recovery was performed through analysis of the permeate flux and properties obtained through polymeric...... and ceramic membranes. Wash water samples were collected at an industrial laundering facility for hospital linen and filtered through different ultrafiltration membranes with varying molecular weight cut-off. The critical micelle concentration of the detergent was quantified, and capillarity measurements were...

  8. Optimal Portfolio Choice with Wash Sale Constraints

    DEFF Research Database (Denmark)

    Astrup Jensen, Bjarne; Marekwica, Marcel

    2011-01-01

    We analytically solve the portfolio choice problem in the presence of wash sale constraints in a two-period model with one risky asset. Our results show that wash sale constraints can heavily affect portfolio choice of investors with unrealized losses. The trading behavior of such investors...

  9. Workshop on methods for siting groundwater monitoring wells: Proceedings

    International Nuclear Information System (INIS)

    Jacobson, E.

    1992-02-01

    The primary purpose of this workshop was to identify methods for the optimum siting of groundwater monitoring wells to minimize the number required that will provide statistically and physically representative samples. In addition, the workshop served to identify information and data gaps, stimulated discussion and provided an opportunity for exchange of ideas between regulators and scientists interested in siting groundwater monitoring wells. These proceedings should serve these objectives and provide a source of relevant information which may be used to evaluate the current state of development of methods for siting groundwater monitoring wells and the additional research needs. The proceedings contain the agenda and list of attendees in the first section. The abstract and viewgraphs for each presentation are given in the second section. For several presentations, abstracts and viewgraphs were not received. After the presentations, four working groups were organized and met for approximately a day. The working group leaders then gave a verbal summary of their sessions. This material was transcribed and is included in the next section of these proceedings. The appendices contain forms describing various methods discussed in the working groups

  10. Changes in soil toxicity by phosphate-aided soil washing: effect of soil characteristics, chemical forms of arsenic, and cations in washing solutions.

    Science.gov (United States)

    Jho, Eun Hea; Im, Jinwoo; Yang, Kyung; Kim, Young-Jin; Nam, Kyoungphile

    2015-01-01

    This study was set to investigate the changes in the toxicity of arsenic (As)-contaminated soils after washing with phosphate solutions. The soil samples collected from two locations (A: rice paddy and B: forest land) of a former smelter site were contaminated with a similar level of As. Soil washing (0.5 M phosphate solution for 2 h) removed 24.5% As, on average, in soil from both locations. Regardless of soil washing, Location A soil toxicities, determined using Microtox, were greater than that of Location B and this could be largely attributed to different soil particle size distribution. With soils from both locations, the changes in As chemical forms resulted in either similar or greater toxicities after washing. This emphasizes the importance of considering ecotoxicological aspects, which are likely to differ depending on soil particle size distribution and changes in As chemical forms, in addition to the total concentration based remedial goals, in producing ecotoxicologically-sound soils for reuse. In addition, calcium phosphate used as the washing solution seemed to contribute more on the toxic effects of the washed soils than potassium phosphate and ammonium phosphate. Therefore, it would be more appropriate to use potassium or ammonium phosphate than calcium phosphate for phosphate-aided soil washing of the As-contaminated soils. Copyright © 2014 Elsevier Ltd. All rights reserved.

  11. WASH activities at two Ebola treatment units in Sierra Leone.

    Directory of Open Access Journals (Sweden)

    Michaela Mallow

    Full Text Available The 2014 outbreak of Ebola virus disease (EVD in West Africa was the largest in history. Starting in September 2014, International Medical Corps (IMC operated five Ebola treatment units (ETUs in Sierra Leone and Liberia. This paper explores how future infectious disease outbreak facilities in resource-limited settings can be planned, organized, and managed by analyzing data collected on water, sanitation, and hygiene (WASH and infection prevention control (IPC protocols.We conducted a retrospective cohort study by analyzing WASH/IPC activity data routinely recorded on paper forms or white boards at ETUs during the outbreak and later merged into a database from two IMC-run ETUs in Sierra Leone between December 2014 and December 2015.The IMC WASH/IPC database contains data from over 369 days. Our results highlight parameters key to designing and maintaining an ETU. High concentration chlorine solution usage was highly correlated with both daily patient occupancy and high-risk zone staff entries; low concentration chlorine usage was less well explained by these measures. There is high demand for laundering and disinfecting of personal protective equipment (PPE on a daily basis and approximately 1 (0-4 piece of PPE is damaged each day.Lack of standardization in the type and format of data collected at ETUs made constructing the WASH/IPC database difficult. However, the data presented here may help inform humanitarian response operations in future epidemics.

  12. Laboratory testing in-tank sludge washing, summary letter report

    International Nuclear Information System (INIS)

    Norton, M.V.; Torres-Ayala, F.

    1994-09-01

    In-tank washing is being considered as a means of pretreating high-level radioactive waste sludges, such as neutralized current acid waste (NCAW) sludge. For this process, the contents of the tank will be allowed to settle, and the supernatant solution will be decanted and removed. A dilute sodium hydroxide/sodium nitrite wash solution will be added to the settled sludge and the tank contents will be mixed with a mixer pump system to facilitate washing of the sludge. After thorough mixing, the mixer pumps will be shut off and the solids will be allowed to re-settle. After settling, the supernatant solution will be withdrawn from the tank, and the wash cycle will be repeated several times with fresh wash solution. Core sample data of double shell tank 241-AZ-101 indicate that settling of NCAW solids may be very slow. A complicating factor is that strong thermal currents are expected to be generated from heat produced by radionuclides in the sludge layer at the bottom of the tank. Additionally, there are concerns that during the settling period (i.e., while mixing pumps and air-lift re-circulators are shut off), the radionuclides may heat the residual interstitial water in the sludge to the extent that violent steam discharges (steam bumping) could occur. Finally, there are concerns that during the washing steps sludge settling may be hindered as a result of the reduced ionic strength of the wash solution. To overcome the postulated reduced settling rates during the second and third washing steps, the use of flocculants is being considered. To address the above concerns and uncertainties associated with in-tank washing, PNL has conducted laboratory testing with simulant tank waste to investigate settling rates, steam bump potential, and the need for and use of flocculating agents

  13. Wash Your Hands

    Centers for Disease Control (CDC) Podcasts

    2010-03-08

    This video shows kids how to properly wash their hands, one of the most important steps we can take to avoid getting sick and spreading germs to others.  Created: 3/8/2010 by Centers for Disease Control and Prevention (CDC).   Date Released: 3/8/2010.

  14. The sequential use of washing and an electrochemical reduction process for the remediation of lead-contaminated soils.

    Science.gov (United States)

    Demir, Aydeniz; Köleli, Nurcan

    2013-01-01

    A two-step method for the remediation of three different types of lead (Pb)-contaminated soil was evaluated. The first step included soil washing with ethylenediaminetetraacetic acid (EDTA) to remove Pb from soils. The washing experiments were performed with 0.05 M Na2EDTA at 1:10 soil to liquid ratio. Following the washing, Pb removal efficiency from soils ranged within 50-70%. After the soil washing process, Pb2+ ions in the washing solution were reduced electrochemically in a fixed-bed reactor. Lead removal efficiency with the electrochemical reduction at -2.0 V potential ranged within 57-76%. The overall results indicate that this two-step method is an environmentally-friendly and effective technology to remediate Pb-contaminated soils, as well as Pb-contaminated wastewater treatment due to the transformation of toxic Pb2+ ions into a non-hazardous metallic form (Pb(0)).

  15. Hydrologic monitoring of a waste-injection well near Milton, Florida, June 1975 - June 1977

    Science.gov (United States)

    Pascale, Charles A.; Martin, J.B.

    1978-01-01

    This report presents the hydraulic and chemical data collected from June 1, 1975, when injection began, to June 30, 1977 through a monitoring program at a deep-well waste-injection system at the American Cyanamid Company's plant near Milton, about 12 miles northwest of Pensacola. The injection system consists of a primary injection well, a standby injection well, and two deep monitor wells all completed open hole in the lower limestone of the Floridan aquifer and one shallow-monitor well completed in the upper limestone of the Floridan aquifer. Two of the monitor wells and the standby injection well are used to observe hydraulic and geochemical effects of waste injection in the injection zone at locations 8,180 feet northeast, 1,560 feet south, and 1,025 feet southwest of the primary injection well. The shallow-monitor well, used to observe any effects in the first permeable zone above the 200-foot-thick confining bed, is 28 feet north of the primary injection well. Since injection began in June 1975, 607 million gallons of treated industrial liquid waste with a pH of 4.6 to 6.3 and containing high concentrations of nitrate, organic nitrogen and carbon have been injected into a saline-water-filled limestone aquifer. Wellhead pressure at the injection well in June 1977 average 137 pounds per square inch and the hydraulic pressure gradient was 0.53 pound per square inch per foot of depth to the top of the injection zone. Water levels rose from 36 to 74 feet at the three wells used to monitor the injection zone during the 25-month period. The water level in the shallow-monitor well declined about 8 feet. No changes were detected in the chemical character of water from the shallow-monitor well and deep-monitor well-north. Increases in concentration of bicarbonate and dissolved organic carbon were detected in water from the deep-test monitor well in February 1976 and at the standby injection well in August 1976. In addition to increases in bicarbonate and dissolved

  16. 'If an Eye Is Washed Properly, It Means It Would See Clearly': A Mixed Methods Study of Face Washing Knowledge, Attitudes, and Behaviors in Rural Ethiopia.

    Directory of Open Access Journals (Sweden)

    Kristen Aiemjoy

    2016-10-01

    Full Text Available Face cleanliness is a core component of the SAFE (Surgery, Antibiotics, Facial cleanliness, and Environmental improvements strategy for trachoma control. Understanding knowledge, attitudes, and behaviors related to face washing may be helpful for designing effective interventions for improving facial cleanliness.In April 2014, a mixed methods study including focus groups and a quantitative cross-sectional study was conducted in the East Gojjam zone of the Amhara region of Ethiopia. Participants were asked about face washing practices, motivations for face washing, use of soap (which may reduce bacterial load, and fly control strategies.Overall, both knowledge and reported practice of face washing was high. Participants reported they knew that washing their own face and their children's faces daily was important for hygiene and infection control. Although participants reported high knowledge of the importance of soap for face washing, quantitative data revealed strong variations by community in the use of soap for face washing, ranging from 4.4% to 82.2% of households reporting using soap for face washing. Cost and forgetfulness were cited as barriers to the use of soap for face washing. Keeping flies from landing on children was a commonly cited motivator for regular face washing, as was trachoma prevention.Interventions aiming to improve facial cleanliness for trachoma prevention should focus on habit formation (to address forgetfulness and address barriers to the use of soap, such as reducing cost. Interventions that focus solely on improving knowledge may not be effective for changing face-washing behaviors.

  17. Effects of shampoo and water washing on hair cortisol concentrations.

    Science.gov (United States)

    Hamel, Amanda F; Meyer, Jerrold S; Henchey, Elizabeth; Dettmer, Amanda M; Suomi, Stephen J; Novak, Melinda A

    2011-01-30

    Measurement of cortisol in hair is an emerging biomarker for chronic stress in human and nonhuman primates. Currently unknown, however, is the extent of potential cortisol loss from hair that has been repeatedly exposed to shampoo and/or water. Pooled hair samples from 20 rhesus monkeys were subjected to five treatment conditions: 10, 20, or 30 shampoo washes, 20 water-only washes, or a no-wash control. For each wash, hair was exposed to a dilute shampoo solution or tap water for 45 s, rinsed 4 times with tap water, and rapidly dried. Samples were then processed for cortisol extraction and analysis using previously published methods. Hair cortisol levels were significantly reduced by washing, with an inverse relationship between number of shampoo washes and the cortisol concentration. This effect was mainly due to water exposure, as cortisol levels following 20 water-only washes were similar to those following 20 shampoo treatments. Repeated exposure to water with or without shampoo appears to leach cortisol from hair, yielding values that underestimate the amount of chronic hormone deposition within the shaft. Collecting samples proximal to the scalp and obtaining hair washing frequency data may be valuable when conducting human hair cortisol studies. Copyright © 2010 Elsevier B.V. All rights reserved.

  18. Wash water waste pretreatment system

    Science.gov (United States)

    1977-01-01

    Investigations were completed on wash waters based on each candidate personal cleansing agent. Evaluations of coagulants, antifoam agents, and the effect of promising antifoams on the chemical precipitation were included. Based on these evaluations two candidate soaps as well as their companion antifoam agents were selected for further work. Operating parameters included the effect of soap concentration, ferric chloride concentration, duration of mixing, and pore size of depth filters on the degree of soap removal. The effect of pressure on water flow through filter cartridges and on the rate of decline of water flow was also investigated. The culmination of the program was the recommendation of a pretreatment concept based on chemical precipitation followed by pressure filtration.

  19. A method for treating clayless wash fluids

    Energy Technology Data Exchange (ETDEWEB)

    Deykalo, T A; Dzhumagaliyev, T N; Skvortsov, D S

    1980-02-18

    To increase the heat and salt resistance of a wash fluid, monoethanolamine processed waste of licorice production - grist in a volume of 5-8% by weight, is introduced into it as the disperse phase. The processing of the grist is conducted for 1-2 hours at 20-100/sup 0/C and the volume of the monoethanolamine is 0.05-0.1% by weight. The properties of the washing fluids treated by the grist with the introduction of 20% CaC1/sub 2/ into them were not deteriorated, while complete coagulation was achieved with its introduction into washing fluids on the basis of KMTs. Grist washing liquids do not deteriorate their own properties to a temperature of 200/sup 0/C, do not cause equipment corrosion, are inert to swelling clay rocks and with the introduction of KMTs at a temperature above 130-140/sup 0/C cause insignificant destruction of the reagent which is accompanied by a change in the color of the solutions and a drop in the degree of polymerization and viscosity.

  20. Chlorides behavior in raw fly ash washing experiments

    International Nuclear Information System (INIS)

    Zhu Fenfen; Takaoka, Masaki; Oshita, Kazuyuki; Kitajima, Yoshinori; Inada, Yasuhiro; Morisawa, Shinsuke; Tsuno, Hiroshi

    2010-01-01

    Chloride in fly ash from municipal solid waste incinerators (MSWIs) is one of the obstructive substances in recycling fly ash as building materials. As a result, we have to understand the behavior of chlorides in recycling process, such as washing. In this study, we used X-ray absorption near edge structure (XANES) and X-ray diffraction (XRD) to study the chloride behavior in washed residue of raw fly ash (RFA). We found that a combination of XRD and XANES, which is to use XRD to identify the situation of some compounds first and then process XANES data, was an effective way to explain the chlorides behavior in washing process. Approximately 15% of the chlorine in RFA was in the form of NaCl, 10% was in the form of KCl, 51% was CaCl 2 , and the remainder was in the form of Friedel's salt. In washing experiments not only the mole percentage but also the amount of soluble chlorides including NaCl, KCl and CaCl 2 decreases quickly with the increase of liquid to solid (L/S) ratio or washing frequency. However, those of insoluble chlorides decrease slower. Moreover, Friedel's salt and its related compound (11CaO.7Al 2 O 3 .CaCl 2 ) were reliable standards for the insoluble chlorides in RFA, which are strongly related to CaCl 2 . Washing of RFA promoted the release of insoluble chlorides, most of which were in the form of CaCl 2 .

  1. Removal of heavy metals from polluted soil using the citric acid fermentation broth: a promising washing agent.

    Science.gov (United States)

    Zhang, Hongjiao; Gao, Yuntao; Xiong, Huabin

    2017-04-01

    The citric acid fermentation broth was prepared and it was employed to washing remediation of heavy metal-polluted soil. A well-defined washing effect was obtained, the removal percentages using citric acid fermentation broth are that 48.2% for Pb, 30.6% for Cu, 43.7% for Cr, and 58.4% for Cd and higher than that using citric acid solution. The kinetics of heavy metals desorption can be described by the double constant equation and Elovich equation and is a heterogeneous diffusion process. The speciation analysis shows that the citric acid fermentation broth can effectively reduce bioavailability and environmental risk of heavy metals. Spectroscopy characteristics analysis suggests that the washing method has only a small effect on the mineral composition and does not destroy the framework of soil system. Therefore, the citric acid fermentation broth is a promising washing agent and possesses a potential practical application value in the field of remediation of soils with a good washing performance.

  2. A novel washing algorithm for underarm stain removal

    Science.gov (United States)

    Acikgoz Tufan, H.; Gocek, I.; Sahin, U. K.; Erdem, I.

    2017-10-01

    After contacting with human sweat which comprise around 27% sebum, anti-perspirants comprising aluminium chloride or its compounds form a jel-like structure whose solubility in water is very poor. In daily use, this jel-like structure closes sweat pores and hinders wetting of skin by sweat. However, when in contact with garments, they form yellowish stains at the underarm of the garments. These stains are very hard to remove with regular machine washing. In this study, first of all, we focused on understanding and simulating such stain formation on the garments. Two alternative procedures are offered to form jel-like structures. On both procedures, commercially available spray or deo-stick type anti-perspirants, standard acidic and basic sweat solutions and artificial sebum are used to form jel-like structures, and they are applied on fabric in order to get hard stains. Secondly, after simulation of the stain on the fabric, we put our efforts on developing a washing algorithm specifically designed for removal of underarm stains. Eight alternative washing algorithms are offered with varying washing temperature, amounts of detergent, and pre-stain removal procedures. Better algorithm is selected by comparison of Tristimulus Y values after washing.

  3. COMPILATION OF LABORATORY SCALE ALUMINUM WASH AND LEACH REPORT RESULTS

    International Nuclear Information System (INIS)

    Harrington, S.J.

    2011-01-01

    This report compiles and analyzes all known wash and caustic leach laboratory studies. As further data is produced, this report will be updated. Included are aluminum mineralogical analysis results as well as a summation of the wash and leach procedures and results. Of the 177 underground storage tanks at Hanford, information was only available for five individual double-shell tanks, forty-one individual single-shell tanks (e.g. thirty-nine 100 series and two 200 series tanks), and twelve grouped tank wastes. Seven of the individual single-shell tank studies provided data for the percent of aluminum removal as a function of time for various caustic concentrations and leaching temperatures. It was determined that in most cases increased leaching temperature, caustic concentration, and leaching time leads to increased dissolution of leachable aluminum solids.

  4. COMPILATION OF LABORATORY SCALE ALUMINUM WASH AND LEACH REPORT RESULTS

    Energy Technology Data Exchange (ETDEWEB)

    HARRINGTON SJ

    2011-01-06

    This report compiles and analyzes all known wash and caustic leach laboratory studies. As further data is produced, this report will be updated. Included are aluminum mineralogical analysis results as well as a summation of the wash and leach procedures and results. Of the 177 underground storage tanks at Hanford, information was only available for five individual double-shell tanks, forty-one individual single-shell tanks (e.g. thirty-nine 100 series and two 200 series tanks), and twelve grouped tank wastes. Seven of the individual single-shell tank studies provided data for the percent of aluminum removal as a function of time for various caustic concentrations and leaching temperatures. It was determined that in most cases increased leaching temperature, caustic concentration, and leaching time leads to increased dissolution of leachable aluminum solids.

  5. The effect of silica in washing with geothermal water, Iceland

    International Nuclear Information System (INIS)

    Lindal, B.

    1992-01-01

    Industrial washing operation using geothermal water in Iceland are reported and testing designed to explain the beneficial effect of geothermal water for washing described. The findings indicate, that the silica content of the water may be the principal component for a superior washing quality

  6. Towards a durability test for washing-machines.

    Science.gov (United States)

    Stamminger, Rainer; Tecchio, Paolo; Ardente, Fulvio; Mathieux, Fabrice; Niestrath, Phoebe

    2018-04-01

    Durability plays a key role in enhancing resource conservation and contributing to waste minimization. The washing-machine product group represents a relevant case study for the development of a durability test and as a potential trigger to systematically address durability in the design of products. We developed a procedure to test the durability performance of washing-machines as a main objective of this research. The research method consisted of an analysis of available durability standards and procedures to test products and components, followed by an analysis of relevant references related to frequent failures. Finally, we defined the criteria and the conditions for a repeatable, relatively fast and relevant endurance test. The durability test considered the whole product tested under conditions of stress. A series of spinning cycles with fixed imbalanced loads was run on two washing-machines to observe failures and performance changes during the test. Even though no hard failures occurred, results clearly showed that not all washing-machines can sustain such a test without abrasion or performance deterioration. However, the attempt to reproduce the stress induced on a washing-machine by carrying out a high number of pure spinning cycles with fixed loads did not allow equal testing conditions: the actions of the control procedure regarding imbalanced loads differ from machine to machine. The outcomes of this research can be used as grounds to develop standardised durability tests and to, hence, contribute to the development of future product policy measures.

  7. Remediation of a radioactively contaminated soil using a mobile soil-washing system

    International Nuclear Information System (INIS)

    Grant, D.C.; Lahoda, E.J.; Dietrich, A.J.; Weigle, D.H.; Keegan, C.P.; Sachse, J.D.

    1993-01-01

    In order to obtain free-release of a former uranium mining site in Texas, it was required that the surface soil meet specific radiological guidelines. The soil has been contaminated with uranium and radium as a result of the spillage of well-drilling material, process solutions, and ion exchange resins during mining. To meet the required guidelines, the contaminated soil had to be either removed and disposed of off-site or remediated. For economic and long-term liability reasons, remediation of the soil by soil washing was performed. The remediation of this site utilizing the Scientific Ecology Group's soil washing system is discussed in this paper

  8. Environmental monitoring well housing and protection method

    International Nuclear Information System (INIS)

    Kenner, D.A.

    1991-01-01

    This patent describes a method for housing and protecting an environmental monitoring well having a well pipe disposed in a well bore with an upper and extending toward the surface of the ground. It comprises: placing an enclosure ins aid well bore around the upper end of the well pipe, the enclosure being of unitary construction and having an upper opening, a lower opening and an inwardly-protruding ledge between the upper opening and the lower opening, placing sealing means in the well bore between the outter surface of the well pipe and the inner surface of the enclosure, the sealing means being a composition distinct from the well pipe; placing on the ledge a flexible gasket having a shape substantially identical to the shape of the surface of the ledge; placing on the gasket within the enclosure a cover having an upper surface and a peripheral shape substantially identical to the shape of the interior of the enclosure, and attaching the cover to the enclosure so that the upper opening of the enclosure and the upper surface of the cover are substantially flush with the surface of the ground

  9. Investigation of washing and storage strategy on aging Of Mg-aminoclay (MgAC) coated nanoscale zero-valent iron (nZVI) particles

    DEFF Research Database (Denmark)

    Hwang, Yuhoon; Lee, Young-Chul; Mines, Paul D.

    2014-01-01

    The tendency towards agglomeration and oxidation of nanoscale zero-valent iron (nZVI) particles limits its application for in situ groundwater and soil remediation. Although the effect of surface coatings on nanoparticle stabilization has been commonly practiced, the effect of preparation...... correlations (r2 > 0.95, p one another. Pre-storage washing, followed by addition of MgAC, exhibits high stability as pre-storage washing, as well as high reactivity as post-storage washing. Here, it is found that the proper washing procedure is crucial in coated nZVI preparation...

  10. Hand washing frequencies and procedures used in retail food services.

    Science.gov (United States)

    Strohbehn, Catherine; Sneed, Jeannie; Paez, Paola; Meyer, Janell

    2008-08-01

    Transmission of viruses, bacteria, and parasites to food by way of improperly washed hands is a major contributing factor in the spread of foodborne illnesses. Field observers have assessed compliance with hand washing regulations, yet few studies have included consideration of frequency and methods used by sectors of the food service industry or have included benchmarks for hand washing. Five 3-h observation periods of employee (n = 80) hand washing behaviors during menu production, service, and cleaning were conducted in 16 food service operations for a total of 240 h of direct observation. Four operations from each of four sectors of the retail food service industry participated in the study: assisted living for the elderly, childcare, restaurants, and schools. A validated observation form, based on 2005 Food Code guidelines, was used by two trained researchers. Researchers noted when hands should have been washed, when hands were washed, and how hands were washed. Overall compliance with Food Code recommendations for frequency during production, service, and cleaning phases ranged from 5% in restaurants to 33% in assisted living facilities. Procedural compliance rates also were low. Proposed benchmarks for the number of times hand washing should occur by each employee for each sector of food service during each phase of operation are seven times per hour for assisted living, nine times per hour for childcare, 29 times per hour for restaurants, and 11 times per hour for schools. These benchmarks are high, especially for restaurant employees. Implementation would mean lost productivity and potential for dermatitis; thus, active managerial control over work assignments is needed. These benchmarks can be used for training and to guide employee hand washing behaviors.

  11. Ceramic wash-coat for catalyst support

    Science.gov (United States)

    Kulkarni, Anand A.; Subramanian, Ramesh; Sabol, Stephen M.

    2012-08-14

    A wash-coat (16) for use as a support for an active catalyst species (18) and a catalytic combustor component (10) incorporating such wash-coat. The wash-coat is a solid solution of alumina or alumina-based material (Al.sub.2O.sub.3-0-3 wt % La.sub.2O.sub.3) and a further oxide exhibiting a coefficient of thermal expansion that is lower than that exhibited by alumina. The further oxide may be silicon dioxide (2-30 wt % SiO.sub.2), zirconia silicate (2-30 wt % ZrSiO.sub.4), neodymium oxide (0-4 wt %), titania (Al.sub.2O.sub.3-3-40% TiO.sub.2) or alumina-based magnesium aluminate spinel (Al.sub.2O.sub.3-25 wt % MgO) in various embodiments. The active catalyst species may be palladium and a second metal in a concentration of 10-50% of the concentration of the palladium.

  12. Study of electroflotation method for treatment of wastewater from washing soil contaminated by heavy metals

    OpenAIRE

    de Oliveira da Mota, Izabel; de Castro, José Adilson; de Góes Casqueira, Rui; de Oliveira Junior, Angelo Gomes

    2015-01-01

    Electroflotation method (EFM) for treatment of synthetic solutions simulating wastewater from washing soil contaminated by drilling fluids from oil wells was investigated in this paper. Experiments were carried out to examine the effects of the operating conditions on the removal of lead, barium and zinc from solutions containing 15 mg dm−3 for each metal representing a typical concentration of wastewater generated in the washing soil in this treatment. The experimental results showed that it...

  13. Chlorides behavior in raw fly ash washing experiments.

    Science.gov (United States)

    Zhu, Fenfen; Takaoka, Masaki; Oshita, Kazuyuki; Kitajima, Yoshinori; Inada, Yasuhiro; Morisawa, Shinsuke; Tsuno, Hiroshi

    2010-06-15

    Chloride in fly ash from municipal solid waste incinerators (MSWIs) is one of the obstructive substances in recycling fly ash as building materials. As a result, we have to understand the behavior of chlorides in recycling process, such as washing. In this study, we used X-ray absorption near edge structure (XANES) and X-ray diffraction (XRD) to study the chloride behavior in washed residue of raw fly ash (RFA). We found that a combination of XRD and XANES, which is to use XRD to identify the situation of some compounds first and then process XANES data, was an effective way to explain the chlorides behavior in washing process. Approximately 15% of the chlorine in RFA was in the form of NaCl, 10% was in the form of KCl, 51% was CaCl(2), and the remainder was in the form of Friedel's salt. In washing experiments not only the mole percentage but also the amount of soluble chlorides including NaCl, KCl and CaCl(2) decreases quickly with the increase of liquid to solid (L/S) ratio or washing frequency. However, those of insoluble chlorides decrease slower. Moreover, Friedel's salt and its related compound (11CaO.7Al(2)O(3).CaCl(2)) were reliable standards for the insoluble chlorides in RFA, which are strongly related to CaCl(2). Washing of RFA promoted the release of insoluble chlorides, most of which were in the form of CaCl(2). Copyright 2010 Elsevier B.V. All rights reserved.

  14. Humic substances as a washing agent for Cd-contaminated soils.

    Science.gov (United States)

    Meng, Fande; Yuan, Guodong; Wei, Jing; Bi, Dongxue; Ok, Yong Sik; Wang, Hailong

    2017-08-01

    Cost-effective and eco-friendly washing agents are in demand for Cd contaminated soils. Here, we used leonardite-derived humic substances to wash different types of Cd-contaminated soils, namely, a silty loam (Soil 1), a silty clay loam (Soil 2), and a sandy loam (Soil 3). Washing conditions were investigated for their effects on Cd removal efficiency. Cadmium removal was enhanced by a high humic substance concentration, long washing time, near neutral pH, and large solution/soil ratio. Based on the tradeoff between efficiency and cost, an optimum working condition was established as follows: humic substance concentration (3150 mg C/L), solution pH (6.0), washing time (2 h) and a washing solution/soil ratio (5). A single washing removed 0.55 mg Cd/kg from Soil 1 (1.33 mg Cd/kg), 2.32 mg Cd/kg from Soil 2 (6.57 mg Cd/kg), and 1.97 mg Cd/kg from Soil 3 (2.63 mg Cd/kg). Cd in effluents was effectively treated by adding a small dose of calcium hydroxide, reducing its concentration below the discharge limit of 0.1 mg/L in China. Being cost-effective and safe, humic substances have a great potential to replace common washing agents for the remediation of Cd-contaminated soils. Besides being environmentally benign, humic substances can improve soil physical, chemical, and biological properties. Copyright © 2017 Elsevier Ltd. All rights reserved.

  15. Hand Washing Practices and Compliance among Health Care ...

    African Journals Online (AJOL)

    Hand washing is the simplest, most inexpensive and most effective method of reducing the incidence of hospital-acquired infections in the Intensive Care Unit. Several reports have shown a relationship between improved hand washing practices and reduced infection rates. We conducted a prospective, ...

  16. Functional design criteria for FY 1993-2000 groundwater monitoring wells

    International Nuclear Information System (INIS)

    Williams, B.A.

    1996-01-01

    The purpose of this revision is to update the Line Item Project, 93-L-GFW-152 Functional Design Criteria (FDC) to reflect changes approved in change control M-24-91-6, Engineering Change Notices (ECNs), and expand the scope to include subsurface investigations along with the borehole drilling. This revision improves the ability and effectiveness of maintaining RCRA and Operational groundwater compliance by combining borehole and well drilling with subsurface data gathering objectives. The total projected number of wells to be installed under this project has decreased from 200 and the scope has been broadened to include additional subsurface investigation activities that usually occur simultaneously with most traditional borehole drilling and monitoring well installations. This includes borehole hydrogeologic characterization activities, and vadose monitoring. These activities are required under RCRA 40 CFR 264 and 265 and WAC 173-303 for site characterization, groundwater and vadose assessment and well placement

  17. Soil washing for brine removal

    International Nuclear Information System (INIS)

    Ayyachamy, J.S.; Atalay, A.; Zaman, M.

    1992-01-01

    During the exploration for oil and thereafter, brine transfer lines get ruptured releasing the brine which contaminates the surrounding soil. The salinity level in brine is very high, sometimes approaching or exceeding that of sea water. Soils contaminated with brine are unproductive and unsuitable for plant growth. Several investigators have documented the pollution of surface water and groundwater due to brine disposal from oil and needed to clean up such sites. The objective of this study is to develop a soil washing technique that can be used to remove brine sites were collected and used in the study. This paper reports on results which indicate that soil washing using various surface active agents is effective in removing the brine

  18. Water saving in IC wafer washing process; IC wafer senjo deno sessui taisaku

    Energy Technology Data Exchange (ETDEWEB)

    Harada, H. [Mitsubishi Corp., Tokyo (Japan); Araki, M.; Nakazawa, T.

    1997-11-30

    This paper reports features of a wafer washing technology, a new IC wafer washing process, its pure water saving effect, and a `QC washing` which has pure water saving effect in the wafer washing. Wafer washing processes generally include the SC1 process (using ammonia + hydrogen peroxide aqueous solution) purposed for removing contamination due to ultrafine particles, the SC2 process (using hydrochloric acid + hydrogen peroxide aqueous solution) purposed for removing contamination due to heavy metals, the piranha washing process (using hot sulfuric acid + hydrogen peroxide aqueous solution) purposed for removing contamination due to organic matters, and the DHF (using dilute hydrofluoric acid) purposed for removing natural oxide films. Natural oxide films are now remained as surface protection films, by which surface contamination has been reduced remarkably. A high-temperature washing chemical circulating and filtering technology developed in Japan has brought about a reform in wafer washing processes having been used previously. Spin washing is used as a water saving measure, in which washing chemicals or pure water are sprayed onto one each of wafers which is spin-rotated, allowing washing and rinsing to be made with small amount of washing chemicals and pure water. The QC washing is a method to replace tank interior with pure was as quick as possible in order to increase the rinsing effect. 7 refs., 5 figs.

  19. Effects of process parameters on ozone washing for denim using 3/sup 3/ factorial design

    International Nuclear Information System (INIS)

    Asim, F.; Mahmood, M.

    2017-01-01

    Denim garment is getting popular day by day. It is highly demandable because of its versatility, comfort and durability. Different techniques of denim washing increase this demand drastically. Denim washing is the process to enhance the appearance of a garment. This enhanced appearance may be the aged look, faded look, greyer cast, or any other shade setting or resin application. The two most advanced washing techniques are; ozone wash and laser wash. The effects of ozone on environment as well as on the garment are significant and cannot be neglected because number of benefits achieved such as time saving, less energy consumption, chemical, labour cost reduction, less discharge of water and chemicals. Therefore, effects of process parameters on ozone washing for denim fabric have been investigated in this research work using three level factorial design. 33 factorial design has been designed and conducted to investigate the effect of gas concentration, time and speed on the response variables namely; Shrinkage, Tensile and Tear strength of ozone washing. The influence of individual factors and their interactions has been critically examined using software Design Expert 8.0. Prior to the analysis of variance model accuracy has been examined through various residuals plots. The study of residuals plots shown that the residuals are normally distributed and significant evidence of possible outliers was not found. So the model can be used to predicted results with 95% confidence interval. The results from the experiment suggest that two out of three factors were significant, which are speed and time that influences mainly on the tear strength of the denim garment. (author)

  20. UO2 production process with methanol washing

    International Nuclear Information System (INIS)

    Sondermann, T.

    1978-01-01

    The invention refers to a process for the recovery of methanol used for washing the ammonium uranyl carbonate obtained during UO 2 production. The methanol contains about 50% H 2 O, about 10% (NH 4 ) 2 CO 3 , and is radioactive. According to the invention the methanol is purified at reduced pressure in a distillation unit and then led back to the washing unit. (UWI) 891 HP/UWI 892 MBE [de

  1. The source of groundwater and solutes to Many Devils Wash at a former uranium mill site in Shiprock, New Mexico

    Science.gov (United States)

    Robertson, Andrew J.; Ranalli, Anthony J.; Austin, Stephen A.; Lawlis, Bryan R.

    2016-04-21

    The Shiprock Disposal Site is the location of the former Navajo Mill (Mill), a uranium ore-processing facility, located on a terrace overlooking the San Juan River in the town of Shiprock, New Mexico. Following the closure of the Mill, all tailings and associated materials were encapsulated in a disposal cell built on top of the former Mill and tailings piles. The milling operations, conducted at the site from 1954 to 1968, created radioactive tailings and process-related wastes that are now found in the groundwater. Elevated concentrations of constituents of concern—ammonium, manganese, nitrate, selenium, strontium, sulfate, and uranium—have also been measured in groundwater seeps in the nearby Many Devils Wash arroyo, leading to the inference that these constituents originated from the Mill. These constituents have also been reported in groundwater that is associated with Mancos Shale, the bedrock that underlies the site. The objective of this report is to increase understanding of the source of water and solutes to the groundwater beneath Many Devils Wash and to establish the background concentrations for groundwater that is in contact with the Mancos Shale at the site. This report presents evidence on three working hypotheses: (1) the water and solutes in Many Devils Wash originated from the operations at the former Mill, (2) groundwater in deep aquifers is upwelling under artesian pressure to recharge the shallow groundwater beneath Many Devils Wash, and (3) the groundwater beneath Many Devils Wash originates as precipitation that infiltrates into the shallow aquifer system and discharges to Many Devils Wash in a series of springs on the east side of the wash. The solute concentrations in the shallow groundwater of Many Devils Wash would result from the interaction of the water and the Mancos Shale if the source of water was upwelling from deep aquifers or precipitation.In order to compare the groundwater from various wells to groundwater that has been

  2. An assessment of water, sanitation and hygiene (wash) practices ...

    African Journals Online (AJOL)

    An assessment of water, sanitation and hygiene (wash) practices and quality of routinely ... East African Medical Journal ... There was a high uptake of households with treated drinking water (92%), availability of hand washing facilities in ...

  3. Handbook: Collecting Groundwater Samples from Monitoring Wells in Frenchman Flat, CAU 98

    Energy Technology Data Exchange (ETDEWEB)

    Chapman, Jenny [Desert Research Inst. (DRI), Reno, NV (United States); Lyles, Brad [Desert Research Inst. (DRI), Reno, NV (United States); Cooper, Clay [Desert Research Inst. (DRI), Reno, NV (United States); Hershey, Ron [Desert Research Inst. (DRI), Reno, NV (United States); Healey, John [Desert Research Inst. (DRI), Reno, NV (United States)

    2015-06-01

    CAU. The sampling plan is designed to ensure that monitoring activities occur in compliance with the UGTA Quality Assurance Plan (DOE, 2012). The sampling plan should be referenced for Quality Assurance (QA) elements and procedures governing sampling activities. The NNSS Integrated Sampling Plan specifies the groundwater monitoring that will occur in CAU 98 until the long-term monitoring program is approved in the Closure Report. The plan specifies the wells that must be monitored and categorizes them by their sampling objective with the associated analytical requirements and frequency. Possible sample collection methods and required standard operating procedures are also presented. The intent of this handbook is to augment the NNSS Integrated Sampling Plan by providing well-specific details for the sampling professional implementing the Sampling Plan in CAU 98, Frenchman Flat. This handbook includes each CAU 98 well designated for sampling in the NNSS Integrated Sampling Plan. The following information is provided in the individual well sections: 1. The purpose of sampling. 2. A physical description of the well. 3. The chemical characteristics of the formation water. 4. Recommended protocols for purging and sampling. The well-specific information has been gathered from numerous historical and current sources cited in each section, but two particularly valuable resources merit special mention. These are the USGS NNSS website (http://nevada.usgs.gov/doe_nv/ntsarea5.cfm) and the UGTA Field Operations website (https://ugta.nv.doe.gov/sites/Field%20Operations/default.aspx). 2 Land surface elevation and measuring point for water level measurements in Frenchman Flat were a focus during CAU investigations (see Appendix B, Attachment 1 in Navarro-Intera, 2014). Both websites listed above provide information on the accepted datum for each well. A summary is found on the home page for the well on the USGS website. Additional information is available through a link in the

  4. The suitability of EIT to estimate EELV in a clinical trial compared to oxygen wash-in/wash-out technique.

    Science.gov (United States)

    Karsten, Jan; Meier, Torsten; Iblher, Peter; Schindler, Angela; Paarmann, Hauke; Heinze, Hermann

    2014-02-01

    Open endotracheal suctioning procedure (OSP) and recruitment manoeuvre (RM) are known to induce severe alterations of end-expiratory lung volume (EELV). We hypothesised that EIT lung volumes lack clinical validity. We studied the suitability of EIT to estimate EELV compared to oxygen wash-in/wash-out technique. Fifty-four postoperative cardiac surgery patients were enrolled and received standardized ventilation and OSP. Patients were randomized into two groups receiving either RM after suctioning (group RM) or no RM (group NRM). Measurements were conducted at the following time points: Baseline (T1), after suctioning (T2), after RM or NRM (T3), and 15 and 30 min after T3 (T4 and T5). We measured EELV using the oxygen wash-in/wash-out technique (EELVO2) and computed EELV from EIT (EELVEIT) by the following formula: EELVEITTx,y…=EELVO2+ΔEELI×VT/ΔZ. EELVEIT values were compared with EELVO2 using Bland-Altman analysis and Pearson correlation. Limits of agreement ranged from -0.83 to 1.31 l. Pearson correlation revealed significant results. There was no significant impact of RM or NRM on EELVO2-EELVEIT relationship (p=0.21; p=0.23). During typical routine respiratory manoeuvres like endotracheal suctioning or alveolar recruitment, EELV cannot be estimated by EIT with reasonable accuracy.

  5. Evidence on the Effectiveness of Water, Sanitation, and Hygiene (WASH) Interventions on Health Outcomes in Humanitarian Crises: A Systematic Review.

    Science.gov (United States)

    Ramesh, Anita; Blanchet, Karl; Ensink, Jeroen H J; Roberts, Bayard

    2015-01-01

    Water, sanitation, and hygiene (WASH) interventions are amongst the most crucial in humanitarian crises, although the impact of the different WASH interventions on health outcomes remains unclear. To examine the quantity and quality of evidence on WASH interventions on health outcomes in humanitarian crises, as well as evaluate current evidence on their effectiveness against health outcomes in these contexts. A systematic literature review was conducted of primary and grey quantitative literature on WASH interventions measured against health outcomes in humanitarian crises occurring from 1980-2014. Populations of interest were those in resident in humanitarian settings, with a focus on acute crisis and early recovery stages of humanitarian crises in low and middle-income countries. Interventions of interest were WASH-related, while outcomes of interest were health-related. Study quality was assessed via STROBE/CONSORT criteria. Results were analyzed descriptively, and PRISMA reporting was followed. Of 3963 studies initially retrieved, only 6 published studies measured a statistically significant change in health outcome as a result of a WASH intervention. All 6 studies employed point-of-use (POU) water quality interventions, with 50% using safe water storage (SWS) and 35% using household water treatment (HWT). All 6 studies used self-reported diarrhea outcomes, 2 studies also reported laboratory confirmed outcomes, and 2 studies reported health treatment outcomes (e.g. clinical admissions). 1 study measured WASH intervention success in relation to both health and water quality outcomes; 1 study recorded uptake (use of soap) as well as health outcomes. 2 studies were unblinded randomized-controlled trials, while 4 were uncontrolled longitudinal studies. 2 studies were graded as providing high quality evidence; 3 studies provided moderate and 1 study low quality evidence. The current evidence base on the impact of WASH interventions on health outcomes in humanitarian

  6. Time changes in radiocesium wash-off from various land uses after the Fukushima Daiichi NPP accident

    Science.gov (United States)

    Onda, Yuichi; Kato, Hiroaki; Yoshimura, Kazuya; Tsujimura, Maki; Wakiyama, Yoshifumi; Taniguchi, Keisuke; Sakaguchi, Aya; Yamamoto, Masayoshi

    2014-05-01

    A number of studies have been conducted to monitor and model the time series change of radiocesium transfer through aquatic systems after significant fallout, especially from the Chernobyl disaster. However, no data is available for the temporal changes of radiocesium concentration in environmental materials such as soil and water after the Fukushima Daiichi nuclear power plant accident. Our research team has been monitoring the environmental consequences of radioactive contamination just after the Fukushima Daiichi NPP accident in Yamakiya-district, Kawamata town, Fukushima prefecture. Research items are listed below. 1. Radiocesium wash-off from the runoff-erosion plot under different land use. 2. Measurement of radiocesium transfer in forest environment, in association with hydrological pathways such as throughfall and overlandflow on hillslope. 3. Monitoring on radiocesium concentration in soil water, ground water, and spring water. 4. Monitoring of dissolved and particulate radiocesium concentration in river water, and stream water from the forested catchment. 5.Measurement of radiocesium content in drain water and suspended sediment from paddy field. Our monitoring result demonstrated that the Cs-137 concentration in eroded sediment from the runoff-erosion plot has been almost constant for the past 3 years, however the Cs-137 concentration of suspended sediment from the forested catchment showed slight decrease through time. On the other hand, the suspended sediment from paddy field and those in river water from large catchments exhibited rapid decrease in Cs-137 concentration with time. The decreasing trend of Cs-137 concentration were fitted by the two-component exponential model, differences in decreasing rate of the model were compared and discussed among various land uses and catchment scales. Such analysis can provide important insights into the future prediction of the radiocesium wash-off from catchments with different land uses.

  7. Radiation contamination monitors

    International Nuclear Information System (INIS)

    Kato, Tsutomu; Iba, Hiroshi; Sato, Hiroshi

    1999-01-01

    To make sure of no contamination on people, used articles and working uniforms coming out of the radiation controlled area, nuclear power plants are equipped with radioactive contamination monitors. This paper outlines the basic specifications and advantages of our personnel surface contamination monitors to inspect whole-body surface contamination of people coming out, article surface contamination monitors to inspect the surface and inside contamination of used articles brought out, laundry monitors to inspect surface contamination of working uniforms used in the area before and after a wash, and whole-body counters to inspect and measure the internal contamination of a person out of the area. (author)

  8. Effect of washing on pesticide residues in olives.

    Science.gov (United States)

    Guardia-Rubio, M; Ayora-Cañada, M J; Ruiz-Medina, A

    2007-03-01

    The present work aims at contributing to the knowledge of the fate of 5 pesticides in olives in order to evaluate how washing may affect the presence of these residues in this fruit (and consequently in olive oil). For this purpose, olives were sprayed with commercial formulations containing the active ingredients and a series of analyses were performed for 64 d by using gas chromatography with mass spectrometric detection. Selected pesticides, ranked by their importance, were diuron, terbuthylazine, simazine, alpha-endosulfan, and beta-endosulfan. The pesticide fraction, which was not removable from olives by washing, increased with time after treatment until their degradation started at week 6. Washing performed 1 d after treatment was the most effective in reducing residues, especially for simazine. Consequently, the washing step performed in olive mills could be effective in removing those herbicide residues present in olives as a consequence of contact with contaminated soil for a short time. This happens when olives are dropped and harvested off the ground by means of brushes or suction equipment.

  9. Plutonium recovery from carbonate wash solutions

    International Nuclear Information System (INIS)

    Gray, J.H.; Reif, D.J.; Chostner, D.F.; Holcomb, H.P.

    1991-01-01

    540Periodically higher than expected levels of plutonium are found in carbonate solutions used to wash second plutonium cycle solvent. The recent accumulation of plutonium in carbonate wash solutions has led to studies to determine the cause of that plutonium accumulation, to evaluate the quality of all canyon solvents, and to develop additional criteria needed to establish when solvent quality is acceptable. Solvent from three canyon solvent extraction cycles was used to evaluate technology required to measure tributyl phosphate (TBP) degradation products and was used to evaluate solvent quality criteria during the development of plutonium recovery processes. 1 fig

  10. The impact of WASH-1400 on reactor safety evaluation

    International Nuclear Information System (INIS)

    Tanguy, P.Y.

    1976-01-01

    Trends in reactor safety evaluation in France following the publication of WASH-1400 (the Rasmussen Report) are presented. What is called 'the meteorite case' is first schematically presented as follows: WASH-1400 shows nuclear risk equivalent to meteorite risk and reasonable corrections cannot make many orders of magnitude, consequently present safety rules are adequate. The very impact of WASH-1400 on safety approach is then discussed as for: assistance to deterministic safety analysis, introduction of probabilistic safety criteria, acceptable level of risk, and the use of results in research and reactor operating experience

  11. Hand washing practices amongst medical students in Port Harcourt ...

    African Journals Online (AJOL)

    Nigerian Health Journal ... Rates of hand washing are low world wide even amongst health care workers who are should know about its importance. The aim of ... The greatest motivation for hand washing was fear of contracting disease, whilst ...

  12. 21 CFR 864.9285 - Automated cell-washing centrifuge for immuno-hematology.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Automated cell-washing centrifuge for immuno... Establishments That Manufacture Blood and Blood Products § 864.9285 Automated cell-washing centrifuge for immuno-hematology. (a) Identification. An automated cell-washing centrifuge for immuno-hematology is a device used...

  13. Status report: Pretreatment chemistry evaluation FY1997 -- Wash and leach factors for the single-shell tank waste inventory

    Energy Technology Data Exchange (ETDEWEB)

    Colton, N.G.

    1997-08-01

    The wash factors will be used to partition the single-shell tank (SST) inventory into soluble and insoluble portions. The leach factors will be used to estimate the further removal of bulk analytes, such as chromium, aluminum, and phosphate, as well as minor components. Wash and leach factors are given here for 18 analytes, elements expected to drive the volume of material disposed of as high-level waste (HLW). These factors are determined by a weighting methodology developed earlier by this task. Tank-specific analyte inventory values depicted in Tank Waste Data Summary Worksheets, are calculated from concentrations obtained from characterization reports; the waste density; and the tank waste volume. The experimentally determined percentage of analytes removed by washing and leaching in a particular tank waste are translated into a mass (metric tons) in Experimental Washing and Leaching Data Summary Worksheets.

  14. Status report: Pretreatment chemistry evaluation FY1997 - Wash and leach factors for the single-shell tank waste inventory

    International Nuclear Information System (INIS)

    Colton, N.G.

    1997-08-01

    The wash factors will be used to partition the single-shell tank (SST) inventory into soluble and insoluble portions. The leach factors will be used to estimate the further removal of bulk analytes, such as chromium, aluminum, and phosphate, as well as minor components. Wash and leach factors are given here for 18 analytes, elements expected to drive the volume of material disposed of as high-level waste (HLW). These factors are determined by a weighting methodology developed earlier by this task. Tank-specific analyte inventory values depicted in Tank Waste Data Summary Worksheets, are calculated from concentrations obtained from characterization reports; the waste density; and the tank waste volume. The experimentally determined percentage of analytes removed by washing and leaching in a particular tank waste are translated into a mass (metric tons) in Experimental Washing and Leaching Data Summary Worksheets

  15. Optimal Thawing of Cryopreserved Peripheral Blood Mononuclear Cells for Use in High-Throughput Human Immune Monitoring Studies

    Directory of Open Access Journals (Sweden)

    Ramu A. Subbramanian

    2012-07-01

    Full Text Available Cryopreserved peripheral blood mononuclear cells (PBMC constitute an important component of immune monitoring studies as they allow for efficient batch- testing of samples as well as for the validation and extension of original studies in the future. In this study, we systematically test the permutations of PBMC thawing practices commonly employed in the field and identify conditions that are high and low risk for the viability of PBMC and their functionality in downstream ELISPOT assays. The study identifies the addition of ice-chilled washing media to thawed cells at the same temperature as being a high risk practice, as it yields significantly lower viability and functionality of recovered PBMC when compared to warming the cryovials to 37 °C and adding a warm washing medium. We found thawed PBMC in cryovials could be kept up to 30 minutes at 37 °C in the presence of DMSO before commencement of washing, which surprisingly identifies exposure to DMSO as a low risk step during the thawing process. This latter finding is of considerable practical relevance since it permits batch-thawing of PBMC in high-throughput immune monitoring environments.

  16. An evaluation of different soil washing solutions for remediating arsenic-contaminated soils.

    Science.gov (United States)

    Wang, Yiwen; Ma, Fujun; Zhang, Qian; Peng, Changsheng; Wu, Bin; Li, Fasheng; Gu, Qingbao

    2017-04-01

    Soil washing is a promising way to remediate arsenic-contaminated soils. Most research has mostly focused on seeking efficient extractants for removing arsenic, but not concerned with any changes in soil properties when using this technique. In this study, the removal of arsenic from a heavily contaminated soil employing different washing solutions including H 3 PO 4 , NaOH and dithionite in EDTA was conducted. Subsequently, the changes in soil physicochemical properties and phytotoxicity of each washing technique were evaluated. After washing with 2 M H 3 PO 4 , 2 M NaOH or 0.1 M dithionite in 0.1 M EDTA, the soil samples' arsenic content met the clean-up levels stipulated in China's environmental regulations. H 3 PO 4 washing decreased soil pH, Ca, Mg, Al, Fe, and Mn concentrations but increased TN and TP contents. NaOH washing increased soil pH but decreased soil TOC, TN and TP contents. Dithionite in EDTA washing reduced soil TOC, Ca, Mg, Al, Fe, Mn and TP contents. A drastic color change was observed when the soil sample was washed with H 3 PO 4 or 0.1 M dithionite in 0.1 M EDTA. After adjusting the soil pH to neutral, wheat planted in the soil sample washed by NaOH evidenced the best growth of all three treated soil samples. These results will help with selecting the best washing solution when remediating arsenic-contaminated soils in future engineering applications. Copyright © 2017 Elsevier Ltd. All rights reserved.

  17. First successful multistage hydraulic fracture monitoring for a horizontal well in Mexico

    Energy Technology Data Exchange (ETDEWEB)

    Gutierrez, Guillermo; Rios, Austreberto; Riano, Juan M. [PEMEX, Mexico, DF (Mexico); Sanchez, Adrian; Bustos, Tomas [Schlumberger, Mexico DF (Mexico)

    2008-07-01

    In their constant effort to increase the production from Chicontepec, PEMEX drilled a multilateral well with three horizontal lateral sections; the intention was to increase the production in comparison with vertical wells. In the second arm of this well four intervals were identified to be fractured, this was a new approach since it was the first occasion that multiple fractures were planned in a horizontal well. An important part of the project was the evaluation of the effectiveness of the hydraulic fracturing. This evaluation was performed by micro seismic monitoring during the treatment. This technology allows the detection of events generated during the fluid injection in the reservoir, with receivers located in a nearby monitoring well. The interpretation of this data allows the identification in 3 D space of the fracture locations. This information is valuable for optimization of subsequent treatments and for planning the field development. The data is recorded in real time and can be used to make decisions during the fracturing operation. In this paper we describe the results of the hydraulic fracturing monitoring performed in four intervals in a horizontal well showing the geometry and direction of each one of the fractures. (author)

  18. Winter Maintenance Wash-Water Heavy Metal Removal Pilot Scale Evaluation

    Directory of Open Access Journals (Sweden)

    Christopher M. Miller

    2016-01-01

    Full Text Available To encourage sustainable engineering practices, departments of transportation are interested in reusing winter maintenance truck wash water as part of their brine production and future road application. Traffic-related metals in the wash water, however, could limit this option. The objective of this work was to conduct a pilot scale evaluation of heavy metal (copper, zinc, iron, and lead removal in a filtration unit (maximum flow rate of 45 L/minute containing proprietary (MAR Systems Sorbster® media. Three different trials were conducted and approximately 10,000 L of wash water collected from a winter maintenance facility in Ohio was treated with the pilot unit. Lab studies were also performed on six wash-water samples from multiple facilities to assess particle size removal and estimate settling time as a potential removal mechanism during wash-water storage. Pilot unit total metal removal efficiencies were 79%, 77%, 63%, and 94% for copper, zinc, iron, and lead, respectively. Particle settling calculation estimates for copper and zinc show that 10 hours in storage can also effectively reduce heavy metal concentrations in winter maintenance wash water in excess of 70%. These pilot scale results show promise for reducing heavy metal concentrations to an acceptable level for reuse.

  19. Numerical Simulation of Borehole Flow in Deep Monitor Wells, Pearl Harbor Aquifer, Oahu, Hawaii

    Science.gov (United States)

    Rotzoll, K.; Oki, D. S.; El-Kadi, A. I.

    2010-12-01

    Salinity profiles collected from uncased deep monitor wells are commonly used to monitor freshwater-lens thickness in coastal aquifers. However, vertical flow in these wells can cause the measured salinity to differ from salinity in the adjacent aquifer. Substantial borehole flow has been observed in uncased wells in the Pearl Harbor aquifer, Oahu, Hawaii. A numerical modeling approach, incorporating aquifer hydraulic characteristics and recharge rates representative of the Pearl Harbor aquifer, was used to evaluate the effects of borehole flow on measured salinity profiles from deep monitor wells. Borehole flow caused by vertical hydraulic gradients associated with the natural regional groundwater-flow system and local groundwater withdrawals was simulated. Model results were used to estimate differences between vertical salinity profiles in deep monitor wells and the adjacent aquifer in areas of downward, horizontal, and upward flow within the regional flow system—for cases with and without nearby pumped wells. Aquifer heterogeneity, represented in the model as layers of contrasting permeability, was incorporated in model scenarios. Results from this study provide insight into the magnitude of the differences between vertical salinity profiles from deep monitor wells and the salinity distributions in the aquifers. These insights are relevant and are critically needed for management and predictive modeling purposes.

  20. Automatic washing of hooves can help control digital dermatitis in dairy cows

    DEFF Research Database (Denmark)

    Thomsen, Peter Thorup; Kjær Ersbøll, Annette; Sørensen, Jan Tind

    2012-01-01

    washed with a water and 0.4% soap solution. In experiment 2, hooves were washed with water only. In each experiment, DD was scored in a hoof-trimming chute approximately 60 d after the start of hoof washing. Data were analyzed using a generalized linear mixed model. The outcome was the DD status of each....... In experiment 2, the odds ratio of having DD was 1.27 in the control leg compared with the washed leg. We concluded that automatic washing of hooves with water and soap can help decrease the prevalence of DD in commercial dairy herds....

  1. Sensitive identification of mycobacterial species using PCR-RFLP on bronchial washings.

    Science.gov (United States)

    Hidaka, E; Honda, T; Ueno, I; Yamasaki, Y; Kubo, K; Katsuyama, T

    2000-03-01

    In 98 patients (24 with active pulmonary tuberculosis [TB] lesions, 28 with cured TB lesions, and 46 with nontuberculous opacities [control group] in chest CT scans), we examined whether washing the bronchus after brushing the lesion, then applying polymerase chain reaction-restriction fragment length polymorphism (PCR-RFLP) to the bronchial washings might be useful for diagnosing TB and nontuberculous mycobacteriosis (NTMosis). After biopsy and brushing with a bronchoscope, the bronchus connecting to the lesion was washed with 20 ml saline. The saline used for washing the brushes (5 ml; brushing sample), and 3 to 10 ml saline aspirated through the forceps channel (washing sample) were examined by PCR-RFLP, which proved able to identify Mycobacterium tuberculosis and seven species of nontuberculous mycobacteria (NTM). The values obtained for the sensitivity of the PCR-RFLP with respect to the brushing sample, the washing sample, and both samples mixed together were 70, 76, and 91%, respectively, when only patients who were culture-positive or radiologically improved after antituberculous therapy were considered as showing true infection. A mixture of brushing and washing samples provides useful material for PCR and culture, and the PCR-RFLP used here is a good method for the simultaneous identification of several species of mycobacterium (including M. tuberculosis).

  2. Occupational Hydrofluoric Acid Injury from Car and Truck Washing--Washington State, 2001-2013.

    Science.gov (United States)

    Reeb-Whitaker, Carolyn K; Eckert, Carly M; Anderson, Naomi J; Bonauto, David K

    2015-08-21

    Exposure to hydrofluoric acid (HF) causes corrosive chemical burns and potentially fatal systemic toxicity. Car and truck wash cleaning products, rust removers, and aluminum brighteners often contain HF because it is efficient in breaking down roadway matter. The death of a truck wash worker from ingestion of an HF-based wash product and 48 occupational HF burn cases associated with car and truck washing in Washington State during 2001-2013 are summarized in this report. Among seven hospitalized workers, two required surgery, and all but one worker returned to the job. Among 48 injured workers, job titles were primarily auto detailer, car wash worker, truck wash worker, and truck driver. Because HF exposure can result in potentially severe health outcomes, efforts to identify less hazardous alternatives to HF-based industrial wash products are warranted.

  3. Purification of crude biodiesel using dry washing and membrane technologies

    Directory of Open Access Journals (Sweden)

    I.M. Atadashi

    2015-12-01

    Full Text Available Purification of crude biodiesel is mandatory for the fuel to meet the strict international standard specifications for biodiesel. Therefore, this paper carefully analyzed recently published literatures which deal with the purification of biodiesel. As such, dry washing technologies and the most recent membrane biodiesel purification process have been thoroughly examined. Although purification of biodiesel using dry washing process involving magnesol and ion exchange resins provides high-quality biodiesel fuel, considerable amount of spent absorbents is recorded, besides the skeletal knowledge on its operating process. Further, recent findings have shown that biodiesel purification using membrane technique could offer high-quality biodiesel fuel with less wastewater discharges. Thus, both researchers and industries are expected to benefit from the development of membrane technique in purifying crude biodiesel. As well biodiesel purification via membranes has been shown to be environmentally friendly. For these reasons, it is important to explore and exploit membrane technology to purify crude biodiesel.

  4. Interventions to improve the compliance of health care professionals to hand washing: an integrative review

    Directory of Open Access Journals (Sweden)

    Adriana Cristina de Oliveira

    2013-12-01

    Full Text Available The objective of this study was to identify the main strategies used to improve the compliance of health care professionals to hand washing. This is an integrative literature review, which search included journals in English, Spanish and Portuguese. Twenty—three articles were included. An electronic tool was developed on Microsoft Office Excel and the main results were submitted to descriptive analysis. Of the total studies, 87.1% had before and after designs and several methods were used to monitor compliance rate (direct observation, supply use and self-reported rates. Multimodal interventions were used in 87.0%, and the most often employed were: education, feedback, alcohol being available and posters. The largest challenge identified was not only improving the compliance rates to hand washing, but, most of all, keeping them high. It was observed there is a need to use multimodal strategies that contribute to behavior change considering the local setting. Descriptors: Hand Disinfection; Health Personnel; Cross Infection; Nursing.

  5. Removal of uranium from gravel using soil washing method

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Ilgook; Kim, Kye-Nam; Kim, Seung-Soo; Choi, Jong-Won [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2015-10-15

    The development of nuclear technology has led to increasing radioactive waste containing uranium being released and disposed in the nuclear sites. Fine grained soils with a size of less than 4 mm are normally decontaminated using soil washing and electro-kinetic technologies. However, there have been few studies on the decontamination of gravels with a size of more than 4 mm. Therefore, it is necessary to study the decontamination of gravel contaminated with radionuclides. The main objective of the present study on soil washing was to define the optimal condition for acid treatment of uranium-polluted gravel. In this study, soil washing method was applied to remove uranium from gravel. The gravel was crushed and classified as particle sizes. The gravel particles were treated with sulfuric acid in a shaking incubator at 60 .deg. C and 150 rpm for 3 h. The optimal particle size of gravel for soil washing in removal of uranium was between 0.45 and 2.0 mm.

  6. Bench-scale enhanced sludge washing and gravity settling of Hanford Tank C-106 Sludge

    International Nuclear Information System (INIS)

    Brooks, K.P.; Myers, R.L.; Rappe, K.G.

    1997-01-01

    This report summarizes the results of a bench-scale sludge pretreatment demonstration of the Hanford baseline flowsheet using liter-quantities of sludge from Hanford Site single-shell tank 241-C-106 (tank C-106). The leached and washed sludge from these tests provided Envelope D material for the contractors supporting Tank Waste Remediation System (TWRS) Privatization. Pretreatment of the sludge included enhanced sludge washing and gravity settling tests and providing scale-up data for both these unit operations. Initial and final solids as well as decanted supernatants from each step of the process were analyzed chemically and radiochemically. The results of this work were compared to those of Lumetta et al. (1996a) who performed a similar experiment with 15 grams of C-106, sludge. A summary of the results are shown in Table S.1. Of the major nonradioactive components, those that were significantly removed with enhanced sludge washing included aluminum (31%), chromium (49%), sodium (57%), and phosphorus (35%). Of the radioactive components, a significant amount of 137 Cs (49%) were removed during the enhanced sludge wash. Only a very small fraction of the remaining radionuclides were removed, including 90 Sr (0.4%) and TRU elements (1.5%). These results are consistent with those of the screening test. All of the supernatants (both individually and as a blend) removed from these washing steps, once vitrified as LLW glasses (at 20 wt% Na 2 O), would be less than NRC Class C in TRU elements and less than NRC Class B in 90 Sr

  7. Indicators for Monitoring Water, Sanitation, and Hygiene: A Systematic Review of Indicator Selection Methods

    Directory of Open Access Journals (Sweden)

    Stefanie Schwemlein

    2016-03-01

    Full Text Available Monitoring water, sanitation, and hygiene (WaSH is important to track progress, improve accountability, and demonstrate impacts of efforts to improve conditions and services, especially in low- and middle-income countries. Indicator selection methods enable robust monitoring of WaSH projects and conditions. However, selection methods are not always used and there are no commonly-used methods for selecting WaSH indicators. To address this gap, we conducted a systematic review of indicator selection methods used in WaSH-related fields. We present a summary of indicator selection methods for environment, international development, and water. We identified six methodological stages for selecting indicators for WaSH: define the purpose and scope; select a conceptual framework; search for candidate indicators; determine selection criteria; score indicators against criteria; and select a final suite of indicators. This summary of indicator selection methods provides a foundation for the critical assessment of existing methods. It can be used to inform future efforts to construct indicator sets in WaSH and related fields.

  8. Enhanced salmonella reduction on tomatoes washed in chlorinated water with wash aid T-128

    Science.gov (United States)

    Chlorine is widely used by the fresh and fresh-cut produce industries to reduce microbial populations and to prevent potential pathogen cross contamination during produce washing. However, the organic materials released from produce quickly react with chlorine and degrade its efficacy for pathogen i...

  9. Aqueous treatment of water-sensitive paper objects: capillary unit, blotter wash or paraprint wash?

    NARCIS (Netherlands)

    Schalkx, H.; Iedema, P.; Reissland, B.; van Velzen, B.

    2011-01-01

    Blotter washing andwashing with the capillary unit are both methods used for aqueoustreatment of water-sensitive paper objects. The challenge of thistreatment is to remove water-soluble products while keeping thewater-sensitive medium in its place. In this article the two methodsare compared, along

  10. Cost-effective sampling of ground water monitoring wells. Revision 1

    International Nuclear Information System (INIS)

    Ridley, M.; Johnson, V.

    1995-11-01

    CS is a systematic methodology for estimating the lowest-frequency sampling schedule for a given groundwater monitoring location which will still provide needed information for regulatory and remedial decision-making. Increases in frequency dictated by remedial actions are left to the judgement of personnel reviewing the recommendations. To become more applicable throughout the life cycle of a ground water cleanup project or for compliance monitoring, several improvements are envisioned, including: chemical signature analysis to identify minimum suites of contaminants for a well, a simple flow and transport model so that sampling of downgradient wells are increased before movement of contamination, and a sampling cost estimation capability. By blending qualitative and quantitative approaches, we hope to create a defensible system while retaining interpretation ease and relevance to decision making

  11. Tank issues: Design and placement of floating liquid monitoring wells. Final report

    International Nuclear Information System (INIS)

    Bedinger, M.S.

    1993-02-01

    Liquid product monitoring is the predominant method of external leak detection where the water table is within the zone of excavation. The paper discusses the use of liquid product monitors at new and old tank installations for detecting leaks from underground hydrocarbon storage tanks. The paper discusses the site conditions under which liquid product monitors can be effectively used, conditions which may mitigate or prevent the effective use of liquid product monitors, and the construction and placement of liquid product monitoring wells. Liquid product monitors are not used to determine the rate of tank leak. The rate of tank lead can be determined by other methods such as inventory or internal monitoring methods. Effective use of liquid product monitors or any other method of leak detection requires training and experience on the part of the user

  12. Wash-oil problem

    Energy Technology Data Exchange (ETDEWEB)

    Chlosta, J

    1941-01-01

    Meier-Grolman and others have deduced from experimental studies of the vapor pressure of solutions of benzene in paraffin oil and Solway oil-paraffin oil mixtures that the higher the proportion of aliphatic compounds in a wash oil, the less suitable it is for benzene scrubbing. This generalization is not supported. Paraffin oils from brown-coal tar and low viscous oils from the Fischer-Tropsch hydrocarbon synthesis process are both being successfully used for benzene scrubbing.

  13. Evidence on the Effectiveness of Water, Sanitation, and Hygiene (WASH Interventions on Health Outcomes in Humanitarian Crises: A Systematic Review.

    Directory of Open Access Journals (Sweden)

    Anita Ramesh

    Full Text Available Water, sanitation, and hygiene (WASH interventions are amongst the most crucial in humanitarian crises, although the impact of the different WASH interventions on health outcomes remains unclear.To examine the quantity and quality of evidence on WASH interventions on health outcomes in humanitarian crises, as well as evaluate current evidence on their effectiveness against health outcomes in these contexts.A systematic literature review was conducted of primary and grey quantitative literature on WASH interventions measured against health outcomes in humanitarian crises occurring from 1980-2014. Populations of interest were those in resident in humanitarian settings, with a focus on acute crisis and early recovery stages of humanitarian crises in low and middle-income countries. Interventions of interest were WASH-related, while outcomes of interest were health-related. Study quality was assessed via STROBE/CONSORT criteria. Results were analyzed descriptively, and PRISMA reporting was followed.Of 3963 studies initially retrieved, only 6 published studies measured a statistically significant change in health outcome as a result of a WASH intervention. All 6 studies employed point-of-use (POU water quality interventions, with 50% using safe water storage (SWS and 35% using household water treatment (HWT. All 6 studies used self-reported diarrhea outcomes, 2 studies also reported laboratory confirmed outcomes, and 2 studies reported health treatment outcomes (e.g. clinical admissions. 1 study measured WASH intervention success in relation to both health and water quality outcomes; 1 study recorded uptake (use of soap as well as health outcomes. 2 studies were unblinded randomized-controlled trials, while 4 were uncontrolled longitudinal studies. 2 studies were graded as providing high quality evidence; 3 studies provided moderate and 1 study low quality evidence.The current evidence base on the impact of WASH interventions on health outcomes in

  14. Nitric acid flowsheet with late wash PHA testing

    International Nuclear Information System (INIS)

    Zamecnik, J.R.

    1993-01-01

    This Task Technical Plan outlines the activities to be conducted in the Integrated DWPF Melter System (IDMS) in ongoing support of the Defense Waste Processing Facility (DWPF) Chemical Process Cell (CPC) utilizing the Nitric Acid Flowsheet in the Sludge Receipt and Adjustment Tank (SRAT) and Precipitate Hydrolysis Aqueous (PHA) produced by the Late Wash Flowsheet. The IDMS facility is to be operated over a series of runs (2 to 4) using the Nitric Acid Flowsheet. The PHA will be produced with the Late Wash Flowsheet in the Precipitate Hydrolysis Experimental Facility (PHEF). All operating conditions shall simulate the expected DWPF operating conditions as closely as possible. The task objectives are to perform at least two IDMS runs with as many operating conditions as possible at nominal DWPF conditions. The major purposes of these runs are twofold: verify that the combined Late Wash and Nitric Acid flowsheets produce glass of acceptable quality without additional changes to process equipment, and determine the reproducibility of data from run to run. These runs at nominal conditions will be compared to previous runs made with PHA produced from the Late Wash flowsheet and with the Nitric Acid flowsheet in the SRAT (Purex 4 and Purex 5)

  15. Designing and Developing Automatic Trolley for Washing and Dressing the Wounds

    Directory of Open Access Journals (Sweden)

    Golvardi Yazdi M. S.

    2017-12-01

    Full Text Available Introduction:Many items are needed for dressing including sterile dressing set, antiseptic and washing solutions, leucoplast tape, waste bin for infectious garbage, waste bin for noninfectious garbage, safe disposal trash for sharp cutting instruments, bedpan and sometimes drugs. All the items are laid out on a simple wheeled trolley. The multiplicity of items together with problems in placing tools on trolley, forgetting some items, disturbing sterile condition, falling and damaging equipment and the need for at least two people for each procedure, all are the reasons to design and develop Automatic Trolley for Washing and Dressing the Wounds. Material and Method: To develop a mobile unit which meets our needs for dressing, the trolley patents registered in America and different companies were evaluated as well as the materials and methods used while dressing were considered. Results: Automatic Trolley for Washing and Dressing the Wounds was designed and developed. It comprises the followings: drawer, waste bin for infectious garbage, waste bin for noninfectious garbage, shelves for serum and betadine solution, serum stand, peristaltic pump, flexible tube for connecting serum, a place for bedpan, foot pedal for serum flow, two eye-sensor chambers for solution betadine and scrub, an auxiliary work surface. Conclusion: Due to the usual requirements for dressing, we have designed an equipped mobile unit which covers all the objectives of dressing and increases the speed of procedure. Moreover, due to the contrived equipment on the trolley, procedures are done quickly and second person is not required to assist. Automatic Trolley for Washing and Dressing the Wounds is made up of stainless steel which could be mass housing and commercializing which would play a deserving role in improving the fundamentals of health care and wound treatment.

  16. Biomedical wellness monitoring system based upon molecular markers

    Science.gov (United States)

    Ingram, Whitney

    2012-06-01

    We wish to assist caretakers with a sensor monitoring systems for tracking the physiological changes of homealone patients. One goal is seeking biomarkers and modern imaging sensors like stochastic optical reconstruction microscopy (STORM), which has achieved visible imaging at the nano-scale range. Imaging techniques like STORM can be combined with a fluorescent functional marker in a system to capture the early transformation signs from wellness to illness. By exploiting both microscopic knowledge of genetic pre-disposition and the macroscopic influence of epigenetic factors we hope to target these changes remotely. We adopt dual spectral infrared imaging for blind source separation (BSS) to detect angiogenesis changes and use laser speckle imaging for hypertension blood flow monitoring. Our design hypothesis for the monitoring system is guided by the user-friendly, veteran-preferred "4-Non" principles (noninvasive, non-contact, non-tethered, non-stop-to-measure) and by the NIH's "4Ps" initiatives (predictive, personalized, preemptive, and participatory). We augment the potential storage system with the recent know-how of video Compressive Sampling (CSp) from surveillance cameras. In CSp only major changes are saved, which reduces the manpower cost of caretakers and medical analysts. This CSp algorithm is based on smart associative memory (AM) matrix storage: change features and detailed scenes are written by the outer-product and read by the inner product without the usual Harsh index for image searching. From this approach, we attempt to design an effective household monitoring approach to save healthcare costs and maintain the quality of life of seniors.

  17. 100 Area soil washing treatability test plan

    International Nuclear Information System (INIS)

    1993-03-01

    This test plan describes specifications, responsibilities, and general methodology for conducting a soil washing treatability study as applied to source unit contamination in the 100 Area. The objective ofthis treatability study is to evaluate the use of physical separation systems and chemical extraction methods as a means of separating chemically and radioactively contaminated soil fractions from uncontaminated soil fractions. The purpose of separating these fractions is to minimize the volume of soil requiring permanent disposal. It is anticipated that this treatability study will be performed in two phases of testing, a remedy screening phase and a remedy selection phase. The remedy screening phase consists of laboratory- and bench-scale studies performed by Battelle Pacific Northwest laboratories (PNL) under a work order issued by Westinghouse Hanford Company (Westinghouse Hanford). This phase will be used to provide qualitative evaluation of the potential effectiveness of the soil washing technology. The remedy selection phase, consists of pilot-scale testing performed under a separate service contract to be competitively bid under Westinghouse Hanford direction. The remedy selection phase will provide data to support evaluation of the soil washing technology in future feasibility studies for Interim Remedial Measures (IRMs) or final operable unit (OU) remedies. Performance data from these tests will indicate whether applicable or relevant and appropriate requirements (ARARs) or cleanup goals can be met at the site(s) by application of soil washing. The remedy selection tests wig also allow estimation of costs associated with implementation to the accuracy required for the Feasibility Study

  18. Applicability of the Reactor Safety Study (WASH-1400) to LMFBR risk assessments

    International Nuclear Information System (INIS)

    El-Sheikh, K.A.; Feller, K.G.; Fleischer, L.; Greebler, P.; McDonald, A.; Sultan, P.; Temme, M.I.; Fullwood, R.R.

    1976-01-01

    The feasibility of applying the WASH-1400 methods and data to LMFBR risk assessment is evaluated using the following approach for a selected LMFBR: (1) Structuring the LMFBR risk assessment problem in a modular form similar to WASH-1400; (2) Comparing the predictive tools applicable to each module; (3) Comparing the dependencies among the various modules. It is concluded that the WASH-1400 applicability is limited due to LWR-LMFBR differences in operating environments and accident phenomena. WASH-1400 and LMFBR specific methods applicable to LMFBR risk assessments are indicated

  19. Can washing-pretreatment eliminate the health risk of municipal solid waste incineration fly ash reuse?

    Science.gov (United States)

    Wang, Yao; Pan, Yun; Zhang, Lingen; Yue, Yang; Zhou, Jizhi; Xu, Yunfeng; Qian, Guangren

    2015-01-01

    Although the reuse of washing-pretreated MSWI fly ash bas been a hot topic, the associated risk is still an issue of great concern. The present study investigated the influence of washing-pretreatment on the total contents and bioaccessibility of heavy metals in MSWI fly ash. Furthermore, the study incorporated bioaccessibility adjustment into probabilistic risk assessment, to quantify the health risk from multi-pathway exposure to the concerned chemicals as a result of reusing washed MSWI fly ash. The results revealed that both water-washing and acid-washing process have resulted in the concentrated heavy metal content, and have reduced the bioaccessibility of heavy metals. Besides, the acid-washing process increased the cancer risk in most cases, while the effect of water-washing process was uncertain. However, both water-washing and acid-washing pretreatment could decrease the hazard index based on bioaccesilbility. Despite the uncertainties accompanying these procedures, the results indicated that, in this application scenario, only water-washing or acid-washing process cannot reduce the actual risk from all samples to acceptable level, especially for cancer risk. Copyright © 2014. Published by Elsevier Inc.

  20. 40 CFR 447.10 - Applicability; description of the oil-base solvent wash ink subcategory.

    Science.gov (United States)

    2010-07-01

    ...-base solvent wash ink subcategory. 447.10 Section 447.10 Protection of Environment ENVIRONMENTAL...-Base Solvent Wash Ink Subcategory § 447.10 Applicability; description of the oil-base solvent wash ink...-base ink where the tank washing system uses solvents. When a plant is subject to effluent limitations...

  1. Radionuclide contaminated soil: Laboratory study and economic analysis of soil washing. Final report

    International Nuclear Information System (INIS)

    Fuhrmann, M.; Zhou, H.; Patel, B.; Bowerman, B.; Brower, J.

    1996-01-01

    The objective of the work discussed in this report is to determine if soil washing is a feasible method to remediate contaminated soils from the Hazardous Waste Management Facility (HWMF) at Brookhaven National Laboratory (BNL). The contaminants are predominantly Cs-137 and Sr-90. The authors have assumed that the target activity for Cs-137 is 50 pCi/g and that remediation is required for soils having greater activities. Cs-137 is the limiting contaminant because it is present in much greater quantities than Sr-90. This work was done in three parts, in which they: estimated the volume of contaminated soil as a function of Cs-137 content, determined if simple removal of the fine grained fraction of the soil (the material that is less than 0.063 mm) would effectively reduce the activity of the remaining soil to levels below the 50 pCi/g target, assessed the effectiveness of chemical and mechanical (as well as combinations of the two) methods of soil decontamination. From this analysis the authors were then able to develop a cost estimate for soil washing and for a baseline against which soil washing was compared

  2. The effect of cultivation media and washing whole-cell biocatalysts on monoamine oxidase catalyzed oxidative desymmetrization of 3-azabicyclo[3,3,0]octane

    DEFF Research Database (Denmark)

    Ramesh, Hemalata; Zajkoska, Petra; Rebros, Martin

    2016-01-01

    It is well known that washing whole-cells containing enzyme activities after fermentation, but prior to biocatalysis can improve their activity in the subsequent reaction. In this paper, we quantify the impact of both the fermentation media and cell washing on the performance of whole-cell biocat...

  3. Evaluation of microplastic release caused by textile washing processes of synthetic fabrics.

    Science.gov (United States)

    De Falco, Francesca; Gullo, Maria Pia; Gentile, Gennaro; Di Pace, Emilia; Cocca, Mariacristina; Gelabert, Laura; Brouta-Agnésa, Marolda; Rovira, Angels; Escudero, Rosa; Villalba, Raquel; Mossotti, Raffaella; Montarsolo, Alessio; Gavignano, Sara; Tonin, Claudio; Avella, Maurizio

    2018-05-01

    A new and more alarming source of marine contamination has been recently identified in micro and nanosized plastic fragments. Microplastics are difficult to see with the naked eye and to biodegrade in marine environment, representing a problem since they can be ingested by plankton or other marine organisms, potentially entering the food web. An important source of microplastics appears to be through sewage contaminated by synthetic fibres from washing clothes. Since this phenomenon still lacks of a comprehensive analysis, the objective of this contribution was to investigate the role of washing processes of synthetic textiles on microplastic release. In particular, an analytical protocol was set up, based on the filtration of the washing water of synthetic fabrics and on the analysis of the filters by scanning electron microscopy. The quantification of the microfibre shedding from three different synthetic fabric types, woven polyester, knitted polyester, and woven polypropylene, during washing trials simulating domestic conditions, was achieved and statistically analysed. The highest release of microplastics was recorded for the wash of woven polyester and this phenomenon was correlated to the fabric characteristics. Moreover, the extent of microfibre release from woven polyester fabrics due to different detergents, washing parameters and industrial washes was evaluated. The number of microfibres released from a typical 5 kg wash load of polyester fabrics was estimated to be over 6,000,000 depending on the type of detergent used. The usage of a softener during washes reduces the number of microfibres released of more than 35%. The amount and size of the released microfibres confirm that they could not be totally retained by wastewater treatments plants, and potentially affect the aquatic environment. Copyright © 2017 Elsevier Ltd. All rights reserved.

  4. Evaluation of different water-washing treatments effects on wheat straw combustion properties.

    Science.gov (United States)

    Ma, Qiulin; Han, Lujia; Huang, Guangqun

    2017-12-01

    A series of experiments was conducted to explore the effects of various water-washing solid-liquid ratios (1:50 and 1:10) and the stirring on wheat straw (WS) combustion properties. Comparing different solid-liquid ratio groups, a 16% increment in the higher heating value was obtained for 1:50 groups and only 5% for 1:10 groups relative to the raw material. Moreover, energy was lost 4-26 times greater in 1:10 groups than 1:50 groups. While water-washing reduced the comprehensive combustibility index by 14.89%-32.09%, the index values of washed WS were all higher than 2, indicating good combustion performance. The combustion activation energy of four washed WS were 175, 172, 186, and 176kJ/mol, which were all higher than the 160kJ/mol of WS. The fouling/slagging propensity of washed WS reduced to a lower possibility compared to medium of untreated WS. Overall, the recommended condition for washing WS before combustion is 1:50 ratio without stirring. Copyright © 2017. Published by Elsevier Ltd.

  5. Eye wash water flow direction study: an evaluation of the effectiveness of eye wash devices with opposite directional water flow

    OpenAIRE

    Fogt JS; Jones-Jordan LA; Barr JT

    2018-01-01

    Jennifer S Fogt, Lisa A Jones-Jordan, Joseph T Barr The Ohio State University College of Optometry, Columbus, OH, USA Introduction: New designs of eye wash stations have been developed in which the direction of water flow from the fountain has been reversed, with two water streams originating nasally in both eyes and flowing toward the temporal side of each eye. No study has been done to determine the ideal direction of water flow coming from the eye wash in relation to the eye. Materials ...

  6. Nitrate variability in groundwater of North Carolina using monitoring and private well data models.

    Science.gov (United States)

    Messier, Kyle P; Kane, Evan; Bolich, Rick; Serre, Marc L

    2014-09-16

    Nitrate (NO3-) is a widespread contaminant of groundwater and surface water across the United States that has deleterious effects to human and ecological health. This study develops a model for predicting point-level groundwater NO3- at a state scale for monitoring wells and private wells of North Carolina. A land use regression (LUR) model selection procedure is developed for determining nonlinear model explanatory variables when they are known to be correlated. Bayesian Maximum Entropy (BME) is used to integrate the LUR model to create a LUR-BME model of spatial/temporal varying groundwater NO3- concentrations. LUR-BME results in a leave-one-out cross-validation r2 of 0.74 and 0.33 for monitoring and private wells, effectively predicting within spatial covariance ranges. Results show significant differences in the spatial distribution of groundwater NO3- contamination in monitoring versus private wells; high NO3- concentrations in the southeastern plains of North Carolina; and wastewater treatment residuals and swine confined animal feeding operations as local sources of NO3- in monitoring wells. Results are of interest to agencies that regulate drinking water sources or monitor health outcomes from ingestion of drinking water. Lastly, LUR-BME model estimates can be integrated into surface water models for more accurate management of nonpoint sources of nitrogen.

  7. Washing-electrokinetic Decontamination for Concrete Contaminated with Cobalt and Cesium

    International Nuclear Information System (INIS)

    Kim, Gye Nam; Yang, Byeong Il; Choi, Wang Kyu; Lee, Kune Woo; Hyeon, Jay Hyeok

    2009-01-01

    A great volume of radioactive concrete is generated during the operation and the decommissioning of nuclear facilities. The washing-electrokinetic technology in this study, which combined an electrokinetic method and a washing method, was developed to decontaminate the concrete generated in nuclear facilities. The results of only an electrokinetic decontamination for the concrete showed that cobalt was removed to below 1% from the concrete due to its high pH. Therefore, the washing electrokinetic technology was applied to lower the pH of the concrete. Namely, when the concrete was washed with 3 M of hydrochloric acid for 4 hours (0.17 day), the CaCO 3 in the concrete was decomposed into CO 2 and the pH of the concrete was reduced to 3.7, and the cobalt and cesium in the concrete were removed by up to 85.0% and 76.3% respectively. Next, when the washed concrete was decontaminated by the electrokinetic method with 0.01M of acetic acid in the 1L electrokinetic equipment for 14.83 days, the cobalt and the cesium in the concrete were both removed by up to 99.7% and 99.6% respectively. The removal efficiencies of the cobalt and cesium by 0.01M of acetic acid were increased more than those by 0.05M of acetic acid due to the increase of the concrete zeta potential. The total effluent volume generated from the washing-electrokinetic decontamination was 11.55L (7.2ml/g).

  8. SOIL-WASHING TECHNOLOGY AND PRACTICE

    Science.gov (United States)

    Soil washing in the United States has been studied and evaluated with increasing thoroughness during the last 15 to 20 years. It is now entering a phase of actual use and acceptance as its applicability and economics become clearer. This paper reviews the principles behind soil...

  9. A STUDY OF ANTIMICROBIAL ACTIVITY OF FOAM-WASHING AGENT SPECIMENS AT ACIDIC pH VALUES

    Directory of Open Access Journals (Sweden)

    Strilets O. P.

    2017-06-01

    Full Text Available Introduction. It is well-known that any parapharmaceutical substance, in particular, foam-washing agents comprising water in combination with detergents, extracts, water-soluble vitamins, viscosity regulators, pH, etc., is the ideal environment for microbial growth. Therefore, it is indispensable to use preservatives to protect any foam-washing agent from possible contamination by microorganisms. Their main advantages are: presence of a single antimicrobial and antifungal effect, expanded range of effects, decrease in the risk of resistance of microorganisms and decrease in the toxicity and concentration of the preserving mixture. In this regard, the shelf life of parapharmaceutical substances is not provided through the use of large quantities of preservatives, but thanks to their rational combination. Materials and Methods. For this study, we have made a number of samples of foam washing bases with a number of preservatives, which are often used in developing foam-washing agents with acidic pH value, namely: sample number 1 – foam washing base + sodium benzoate; sample number 2 – foam washing base + «Euxyl K300» (phenoxyethanol, methylparaben, bulylparaben, ethylparaben, propylparaben, isobutylaraben; sample number 3 – foam washing base + «Germaben II» (polypropylene glycol, diazolium dinomovine, methylparaben, propylparaben; sample number 4 – foam washing base + «Nipaquard CMB» (benzyl alcohol, triethylene glycol, chloromethylisothiazoline, methylisothiazoline. The concentration of preservative in each sample was 0.1% (average concentration that is recommended for developing foam-washing agents. The antimicrobial activity of prototype gels was studied in vitro by diffusion in agar (“wells” method. The antimicrobial activity was measured immediately after sample preparation. All the studies were performed in aseptic conditions using a laminar box (biological safety cabinet AS2-4E1 "Esco" Indonesia. Results. According to the

  10. High performance wash-free magnetic bioassays through microfluidically enhanced particle specificity.

    Science.gov (United States)

    Bechstein, Daniel J B; Lee, Jung-Rok; Ooi, Chin Chun; Gani, Adi W; Kim, Kyunglok; Wilson, Robert J; Wang, Shan X

    2015-06-30

    Magnetic biosensors have emerged as a sensitive and versatile platform for high performance medical diagnostics. These magnetic biosensors require well-tailored magnetic particles as detection probes, which need to give rise to a large and specific biological signal while showing very low nonspecific binding. This is especially important in wash-free bioassay protocols, which do not require removal of particles before measurement, often a necessity in point of care diagnostics. Here we show that magnetic interactions between magnetic particles and magnetized sensors dramatically impact particle transport and magnetic adhesion to the sensor surfaces. We investigate the dynamics of magnetic particles' biomolecular binding and magnetic adhesion to the sensor surface using microfluidic experiments. We elucidate how flow forces can inhibit magnetic adhesion, greatly diminishing or even eliminating nonspecific signals in wash-free magnetic bioassays, and enhancing signal to noise ratios by several orders of magnitude. Our method is useful for selecting and optimizing magnetic particles for a wide range of magnetic sensor platforms.

  11. Impacts of traffic and rainfall characteristics on heavy metals build-up and wash-off from urban roads.

    Science.gov (United States)

    Mahbub, Parvez; Ayoko, Godwin A; Goonetilleke, Ashantha; Egodawatta, Prasanna; Kokot, Serge

    2010-12-01

    An investigation into the effects of changes in urban traffic characteristics due to rapid urbanisation and the predicted changes in rainfall characteristics due to climate change on the build-up and wash-off of heavy metals was carried out in Gold Coast, Australia. The study sites encompassed three different urban land uses. Nine heavy metals commonly associated with traffic emissions were selected. The results were interpreted using multivariate data analysis and decision making tools, such as principal component analysis (PCA), fuzzy clustering (FC), PROMETHEE, and GAIA. Initial analyses established high, low, and moderate traffic scenarios as well as low, low to moderate, moderate, high, and extreme rainfall scenarios for build-up and wash-off investigations. GAIA analyses established that moderate to high traffic scenarios could affect the build-up, while moderate to high rainfall scenarios could affect the wash-off of heavy metals under changed conditions. However, in wash-off, metal concentrations in 1-75 μm fraction were found to be independent of the changes to rainfall characteristics. In build-up, high traffic activities in commercial and industrial areas influenced the accumulation of heavy metal concentrations in particulate size range from 75 - >300 μm, whereas metal concentrations in finer size range of 300 μm can be targeted for removal of Ni, Cu, Pb, Cd, Cr, and Zn from build-up, while organic matter from 300 μm can be targeted for removal of Cd, Cr, Pb, and Ni from wash-off. Cu and Zn need to be removed as free ions from most fractions in wash-off.

  12. Gravity and magnetic study of Yucca Wash, southwest Nevada

    International Nuclear Information System (INIS)

    Langenheim, V.E.; Ponce, D.A.; Oliver, H.W.; Sikora, R.F.

    1993-01-01

    Gravity and ground magnetic data were collected along five traverses across and one traverse along Yucca Wash in the southwest quadrant of the Nevada Test Site. Two additional ground magnetic profiles were collected approximately 100 m to either side of the longitudinal profile. These data do not indicate major vertical offsets greater than 100 m using a density contrast of 0.2 to 0.3 g/cm 3 along the proposed Yucca Wash fault. A broad magnetic high coincides with the location of the hydrologic gradient. Density profiling, a technique used to determine the average density of small topographic features, suggests that the density of near-surface material in the vicinity of Yucca Wash is about 2.0 g/cm 3

  13. Dry washing: the solution for contaminated liquid effluent releases

    International Nuclear Information System (INIS)

    L'homme, D.; Trambouze, P.

    1998-01-01

    The release of wash water used for contaminated garments poses an ever-increasing problem on nuclear sites. Even though the radioactivity is low, it mixes with organic compounds, thus polluting a large quantity of liquid effluents. In many cases, several thousands of m 3 /year per nuclear site are produced, which at times represents more than 30% of the volume of total releases. The conventional dry cleaning process is not a viable option, given that repeated washing cause clothes to fade and the odors are rot removed completely. In order to eliminate releases, STMI has developed, after several years of research with the Technological University of Compiegne, France, a solvent dry washing process for garments used in the nuclear industry. (author)

  14. Effects of egg shell quality and washing on Salmonella Infantis penetration.

    Science.gov (United States)

    Samiullah; Chousalkar, K K; Roberts, J R; Sexton, M; May, D; Kiermeier, A

    2013-07-15

    The vast majority of eggs in Australia are washed prior to packing to remove dirt and fecal material and to reduce the microbial contamination of the egg shell. The egg contents can be an ideal growth medium for microorganisms which can result in human illness if eggs are stored improperly and eaten raw or undercooked, and it is estimated that egg-related salmonellosis is costing Australia $44 million per year. Egg shell characteristics such as shell thickness, amount of cuticle present, and thickness of individual egg shell layers can affect the ease with which bacteria can penetrate the egg shell and washing could partially or completely remove the cuticle layer. The current study was conducted to investigate the effects of egg washing on cuticle cover and effects of egg shell quality and cuticle cover on Salmonella Infantis penetration of the egg shell. A higher incidence of unfavorable ultrastructural variables of the mammillary layer such as late fusion, type B bodies, type A bodies, poor cap quality, alignment, depression, erosion and cubics were recorded in Salmonella penetrated areas of egg shells. The influence of egg washing on the ability of Salmonella Infantis on the egg shell surface to enter the egg internal contents was also investigated using culture-based agar egg penetration and real-time qPCR based experiments. The results from the current study indicate that washing affected cuticle cover. There were no significant differences in Salmonella Infantis penetration of washed or unwashed eggs. Egg shell translucency may have effects on Salmonella Infantis penetration of the egg shell. The qPCR assay was more sensitive for detection of Salmonella Infantis from egg shell wash and internal contents than traditional microbiological methods. The agar egg and whole egg inoculation experiments indicated that Salmonella Infantis penetrated the egg shells. Egg washing not only can be highly effective at removing Salmonella Infantis from the egg shell surface

  15. Bench Scale Treatability Studies of Contaminated Soil Using Soil Washing Technique

    OpenAIRE

    Gupta, M. K.; Srivastava, R. K.; Singh, A. K.

    2010-01-01

    Soil contamination is one of the most widespread and serious environmental problems confronting both the industrialized as well as developing nations like India. Different contaminants have different physicochemical properties, which influence the geochemical reactions induced in the soils and may bring about changes in their engineering and environmental behaviour. Several technologies exist for the remediation of contaminated soil and water. In the present study soil washing technique using...

  16. Gravity and magnetic data of Fortymile Wash, Nevada Test Site, Nevada

    International Nuclear Information System (INIS)

    Ponce, D.A.; Kohrn, S.B.; Waddell, S.

    1992-01-01

    Gravity and ground magnetic data collected along six traverses across Fortymile Wash, in the southwest quadrant of the Nevada Test Site suggest that there are no significant vertical offsets below Fortymile Wash. The largest gravity and magnetic anomaly, in the vicinity of Fortymile Wash, is produced by the Paintbrush fault, on the west flank of Fran Ridge. Inferred vertical offset is about 250 ± 60 m (800 ± 200 ft). Geophysical data indicate that the fault is about 300 m (1,000 ft) east of its mapped, but concealed location. North of Busted Butte, near Fran Ridge, geophysical data do not preclude the existence of small vertical offsets bounding Fortymile Wash. However, gravity and magnetic profiles south of Busted Butte show little correlation to those to the north and suggest that vertical offsets, comparable in size to the Paintbrush fault, are not present. Density profiling, a technique used to determine the average density of small topographic features, suggests that the density of near-surface material in the vicinity of Fortymile Wash is 1.80 to 2.00 g/cm 3

  17. Wastewater Treatment Model in Washing Stations for Vehicles Transporting Dangerous Goods

    Directory of Open Access Journals (Sweden)

    Robert Muha

    2004-09-01

    Full Text Available Car washing is a task performed by every passenger carowner more or less frequently, mainly to achieve a finer appearanceof the vehicle rather than for the need for cleanness.In the transport business, the owner's concern is to presentclean and orderly vehicles on the road as a relevant external elementof order, implying good corporate image to customers. Onthe other hand, in dangerous goods transportation there areother reasons requiring special technology of washing, applicableto the transport means used, depending on the change oftype of goods in carriage, the preliminary preparation of a vehicleto load the cargo, or to undergo maintenance.Water applied in the technology of washing collects the residueof goods carried in the vehicle and is polluted to such an extentthat it cannot be discharged into sewers - nor directly into awatercourse - without previous treatment.The paper presents a solution model and a sequence oftechnological procedures involved in an efficient treatment ofthe polluted wastewater in tank wash stations, in which mostlyvehicles carrying ADR goods are washed.

  18. Water levels in continuously monitored wells in the Yucca Mountain area, Nevada, 1985--88

    International Nuclear Information System (INIS)

    Luckey, R.R.; Lobmeyer, D.H.; Burkhardt, D.J.

    1993-01-01

    Water levels have been monitored hourly in 15 wells completed in 23 depth intervals in the Yucca Mountain area, Nevada. Water levels were monitored using pressure transducers and were recorded by data loggers. The pressure transducers were periodically calibrated by raising and lowering them in the wells. The water levels were normally measured at approximately the same time that the transducers were calibrated. Where the transducer output appeared reasonable, it was converted to water levels using the calibrations and manual water- level measurements. The amount of transducer output that was converted to water levels ranged from zero for several intervals to about 98 percent for one interval. Fourteen of the wells were completed in Tertiary volcanic rocks and one well was completed in Paleozoic carbonate rocks. Each well monitored from one to four depth intervals. Water-level fluctuation caused by barometric pressure changes and earth tides were observed

  19. Evaluation of washing machine load potential for smart grid integration

    NARCIS (Netherlands)

    Klaassen, E.A.M.; Kobus, C.B.A.; Huijkelom, M.; Frunt, J.; Slootweg, J.G.

    2013-01-01

    This paper presents the lessons learned from a smart wash pilot, conducted with 24 employees of distribution system operator Enexis, who were equipped with an energy computer, smart washing machine, photovoltaic panels and smart meter. The pilot goal was to gain experience and knowledge about the

  20. Environmental Impacts Of Zirab Coal Washing Plant, Mazandaran, Iran

    Science.gov (United States)

    Moore, F.; Esmaeili, A.

    2009-04-01

    Extraction and beneficiation operations associated with coal mining increase the rate of chemical reaction of waste material to air and water media. Zirab coal washing plant is located on the bank of the Cherat stream in Mazandaran province, Iran. coal Mined from central Alborz coalfield mines is not suitable for use in Iranian Steel Corporation. Hence, coal ash content is reduced by physical and chemical processes in this plant. These processes leave a large quantity of liquid and solid wastes that accumulate in waste dump and tailing dam. sediment and water samples taken from Sheshrudbar and Cherat streams and also from Talar river show high concentration of Cd, Mo and As in water samples of coal washing plant and the associated drainage. Eh-pH diagrams revealed the chemical species of elements in water. The enrichment factor and geoaccumulation index show that Cd, Hg, Mo and V are enriched in bottom sediments of the coal washing plant and decrease with increasing distance from the plant. Sequential extraction analysis Results of three sediment samples of Cherat stream show that silicate bound is the major phase in samples taken before and after the plant, but adjacent to the plant, organic bound is dominant. The high concentration of Cd and Mo in the water soluble phase, is noticeable and may result in high mobility and bioavailability of these elements. Mann-Whitney and Wilcoxon tests on six samples, before and after the coal washing plant support the obtained results. Keywords: Zirab; coal washing plant; Sequential extraction analysis; Mann-whitney; Wilcoxon; Enrichment factor; Geoaccumulation index.

  1. Soil Chemistry Effect on Feasibility of Cr-decontamination by Acid-Washing

    OpenAIRE

    Isoyama, Masahiro; Wada, Shin-Ichiro

    2006-01-01

    Soil washing with sample acid jas been proven to be effective for removal of cationic heavy metals from contaminated soils. Since the obsorption of anitonic heavy metals is enhanced in acidic medium, the efficiency of acid-washing may not be guaranteed for soils that are doubly contaminated with cationic and anitonic heavy metals. To evaluate the efficiensy of acid-washing, nine soils are artifically contaminated with chromate and chromium was extracted with hydrochrolic acid of 0.5 mmol L[-1...

  2. Road dust emission sources and assessment of street washing effect

    NARCIS (Netherlands)

    Karanasiou, A.; Amato, F.; Moreno, T.; Lumbreras, J.; Borge, R.; Linares, C.; Boldo, E.; Alastuey, A.; Querol, X.

    2014-01-01

    Although previous studies report on the effect of street washing on ambient particulate matter levels, there is a lack of studies investigating the results of street washing on the emission strength of road dust. A sampling campaign was conducted in Madrid urban area during July 2009 where road dust

  3. WASH-1400: quantifying the uncertainties

    International Nuclear Information System (INIS)

    Erdmann, R.C.; Leverenz, F.L. Jr.; Lellouche, G.S.

    1981-01-01

    The purpose of this paper is to focus on the limitations of the WASH-1400 analysis in estimating the risk from light water reactors (LWRs). This assessment attempts to modify the quantification of the uncertainty in and estimate of risk as presented by the RSS (reactor safety study). 8 refs

  4. Washing of Cloth Contaminated with Radionuclides Using a Detergent-free Laundry System

    Energy Technology Data Exchange (ETDEWEB)

    Yim, Sung Paal

    2005-07-01

    In this study, a new laundry system to wash clothes without using detergent (detergent-free) was applied to wash clothes contaminated with radionuclides at the RWTF of KAERI. If the clothes contaminated with radionuclides and soil decontaminated and cleaned by washing without using detergent, the problem caused by the detergent could be solved naturally. The experiment was performed in two stages. In the first stage, washability of the processed water from the detergent=free laundry system was investigated with regard to its decontamination efficiency for the radionuclides and the detergency for the soil by using the test cloth specimens. In the second stage, real working clothes contaminated with radionuclides from the RWTF were washed by using a laundry machine equipped with a detergent-free system. Decontamination and detergency of the clothes were estimated after washing and the wastewater was also analyzed for its properties.

  5. Effect of freezing, hot tumble drying and washing with eucalyptus oil on house dust mites in soft toys.

    Science.gov (United States)

    Chang, Chin-Fu; Wu, Francis Fu-Sheng; Chen, Chi-Ying; Crane, Julian; Siebers, Rob

    2011-09-01

    Soft toys are a major source of house dust mites (HDM) and HDM allergens, and sleeping with soft toys is a significant risk factor for HDM sensitization. We studied three techniques to eliminate HDM from soft toys, namely freezing, hot tumble drying and washing with eucalyptus oil. Thirty-six toys (12 in each treatment group) were enumerated for live HDM by the heat escape method before and after freezing overnight, hot tumble drying for 1 h and washing in 0.2% to 0.4% eucalyptus oil. Freezing, hot tumble drying and washing with eucalyptus oil resulted in significant reductions in live HDM, an average reduction of 95.1%, 89.1% and 95.1%, respectively. Additionally, washing with eucalyptus oil resulted in a significant reduction in HDM allergens as well from a geometric mean of 9.12 μg/g to 0.37 μg/g (p = 0.033). These three HDM elimination techniques give parents of infants effective and acceptable methods of limiting HDM exposure. © 2011 John Wiley & Sons A/S.

  6. Soil washing results for mixed waste pond soils at Hanford

    International Nuclear Information System (INIS)

    Gerber, M.A.; Freeman, H.D.; Baker, E.G.; Riemath, W.F.

    1991-01-01

    Soil washing technology was assessed as a means for remediating soil contaminated with mixed wastes primarily composed of heavy metals and radionuclides. The soils at the US Department of Energy's Hanford Site are considered suitable for soil washing because of their relatively low quantities of silt and clay. However, in a limited number of soil washing experiments using soils from different locations in the north pond of the 300 Area, the degree of decontamination achieved for the coarse fraction of the soil varied considerably. Part of this variation appears to be due to the presence of a discrete layer of contaminated sediment found in some of the samples

  7. Prestart-up hydrogen peroxide solution washing of NPP unit with the RBMK-type reactor

    International Nuclear Information System (INIS)

    Gruzdev, N.I.; Man'kina, N.N.; Al'tshuller, M.A.

    1979-01-01

    Presented are the results of industrial hydrogen peroxide solution washing of condensating-feed system conducted on the second unit of the Kursk NPP. Duration of the washing constituted 8 hours. The hydrogen peroxide concentration during first 4 hours was 10-20 mg/kg at a flow rate of 260 m 2 /h, during the following 4 hours it constituted 2-5 mg/kg at a flow rate of 1000 m 3 /h. It is found out that prestart-up hydrogen peroxide washing of NPP power units with the RBMK-type reactor permits: to simplify essentially the technology and scheme of washing process; to reduce a flow rate of desalt washing water; to except environmental contamination with washing solutions and reagents being neutralized; to reduce the time of washing process; to reduce the time necessary for the achievement of reference water condition factors, and to increase the unit reliability and to improve a radiation situation

  8. Evaluation of Resuspension from Propeller Wash in DoD Harbors

    Science.gov (United States)

    2016-05-01

    in ERDC’s Prop-Wash Tank Resuspension by propeller wash from tugboat: in-situ field data: near-bed velocity field, shear stress, critical shear...samples of sediment and water were collected prior to any resuspension event. A C14 Tractor and a slightly smaller Tiger tug boats were used in San

  9. Biodiesel wash-water reuse using microfiltration: toward zero-discharge strategy for cleaner and economized biodiesel production

    Directory of Open Access Journals (Sweden)

    R. Jaber

    2015-03-01

    Full Text Available A simple but economically feasible refining method to treat and re-use biodiesel wash-water was developed. In detail, microfiltration (MF through depth-filtration configuration was used in different hybrid modules. Then, the treated wash-water was mixed with clean water at different ratios, re-used for biodiesel purification and water-washing efficiency was evaluated based on methyl ester purity analysis. The findings of the present study revealed that depth-filtration-based MF combined with sand filtration/activated carbon separation and 70% dilution rate with fresh water not only achieved standard-quality biodiesel product but also led to up to 15% less water consumption after two rounds of production operations. This would be translated into a considerable reduction in the total volume of fresh water used during the operation process and would also strengthen the environmental-friendly aspects of the biodiesel production process for wastewater generation was obviously cut by the same rate as well.

  10. Following of erosive wash of soil in variants with different intercrops

    Directory of Open Access Journals (Sweden)

    Barbora Badalíková

    2010-01-01

    Full Text Available In a pilot experiment established in a sugar beet growing region the erosive washing away of soil was studied in the years 2006 to 2008. The area is located at an altitude of 246 m with the long-term mean precipitation of 500 mm and the mean annual temperature of 8.4 °C. The soils are classified as Chernozem, moderately heavy, loamy, with a good supply of nutrients, humus content of 2.30 % and an alkaline soil reaction. Slope gradient is 12 %, exposition is NE. To study the role of intercrops in erosion control, three variants were established after the harvest of the main crop, two variants with different intercrops and one (control with no intercrop. These were Variant 1 with Secale cereale L. var. multicaule METZG. ex ALEF., a non-freezing intercrop, Variant 2 with cluster mallow (Malva verticillata L., a freezing intercrop, and a control variant with no intercrop. In Variant 1 Secale cereale L. var. multicaule was desiccated with the herbicide Roundup in early spring. All the variants involved maize as the main crop. In variants 1 and 2, maize was sown in intercrop residues after seedbed preparation by Vario and a compactor. In Variant 3 maize was sown after conventional seedbed preparation. For assessment of soil conditions soil samples were taken to determine soil physical and chemical properties and water content in the soil. Soil loss by erosion was determined using specially-designed pockets. Erosive washing away of soil was monitored during the entire growing season of maize. The variants in which intercrops were used were found very effective in soil erosion control. In Variant 3 (control without surface crop residues, the washing away of soil was recorded with each heavy torrential rain. During the all years the total amount of soil loss by erosion in this treatment was 2.25 t . ha−1.

  11. Effect of egg washing on the cuticle quality of brown and white table eggs.

    Science.gov (United States)

    Leleu, S; Messens, W; De Reu, K; De Preter, S; Herman, L; Heyndrickx, M; De Baerdemaeker, J; Michiels, C W; Bain, M

    2011-10-01

    Egg washing is currently not permitted within the European Union, with few exceptions. This is mainly because there are concerns that cuticle damage could occur during or after the washing process, as a result of a suboptimal operation. In this study, the cuticle coverage levels of 400 washed or unwashed eggs, derived from either a brown or a white egg-laying flock at the end of lay, were compared. The eggs from older hens inherently have poorer cuticle coverage and as a result arguably constitute a greater risk to consumer safety if they are then washed. Thus, the effects of the washing procedure used in this study on cuticle quality were tested under the worst-case scenario. A standard Swedish egg washing process was used. The cuticle coverage of the eggs was assessed by a colorimeter by quantifying the color difference before and after staining with Tartrazine and Green S. The cuticle of an additional 30 eggs from each of the four groups was then visually assessed by scanning electron microscopy. The staining characteristics of the cuticle varied greatly within each group of eggs and showed that the washing process did not lead to cuticle damage. Scanning electron microscopy confirmed that there was no irreversible damage to the cuticle of the washed eggs and that it was not possible to correctly assign the treatment (washed or not) based on a visual assessment. In conclusion, no evidence could be found to suggest that the washing procedure used in this investigation irreversibly changed the quality of the cuticle.

  12. Coagulation-flocculation process applied to wastewaters generated in hydrocarbon-contaminated soil washing: Interactions among coagulant and flocculant concentrations and pH value.

    Science.gov (United States)

    Torres, Luis G; Belloc, Claudia; Vaca, Mabel; Iturbe, Rosario; Bandala, Erick R

    2009-11-01

    Wastewater produced in the contaminated soil washing was treated by means of coagulation-flocculation (CF) process. The wastewater contained petroleum hydrocarbons, a surfactant, i.e., sodium dodecyl sulfate (SDS) as well as salts, brownish organic matter and other constituents that were lixiviated from the soil during the washing process. The main goal of this work was to develop a process for treating the wastewaters generated when washing hydrocarbon-contaminated soils in such a way that it could be recycled to the washing process, and also be disposed at the end of the process properly. A second objective was to study the relationship among the coagulant and flocculant doses and the pH at which the CF process is developed, for systems where methylene blue active substances (MBAS) as well as oil and greases were present. The results for the selection of the right coagulant and flocculant type and dose, the optimum pH value for the CF process and the interactions among the three parameters are detailed along this work. The best coagulant and flocculant were FeCl(3) and Tecnifloc 998 at doses of 4,000 and 1 mg/L, correspondingly at pH of 5. These conditions gave color, turbidity, chemical oxygen demand (COD) and conductivity removals of 99.8, 99.6, 97.1 and 35%, respectively. It was concluded that it is feasible to treat the wastewaters generated in the contaminated soil washing process through CF process, and therefore, wastewaters could be recycled to the washing process or disposed to drainage.

  13. Monitoring well installation plan for the Department of Energy Y-12 Plant, Oak Ridge, Tennessee

    International Nuclear Information System (INIS)

    1997-09-01

    The installation and development of groundwater monitoring wells is a primary element of the Y-12 Plant Groundwater Protection Program (GWPP), which monitors groundwater quality and hydrologic conditions at the Oak Ridge Y-12 Plant. This document is a groundwater monitoring well installation and development plan for the US Department of Energy (DOE) Y-12 Plant located in Oak Ridge, Tennessee. This plan formalizes well installation and construction methods, well development methods, and core drilling methods that are currently implemented at the Y-12 Plant under the auspices of the GWPP. Every three years, this plan will undergo a review, during which revisions necessitated by changes in regulatory requirements or GWPP objectives may be made

  14. Decontamination of electronic waste-polluted soil by ultrasound-assisted soil washing.

    Science.gov (United States)

    Chen, Fu; Yang, Baodan; Ma, Jing; Qu, Junfeng; Liu, Gangjun

    2016-10-01

    Laboratorial scale experiments were performed to evaluate the efficacy of a washing process using the combination of methyl-β-cyclodextrin (MCD) and tea saponin (TS) for simultaneous desorption of hydrophobic organic contaminants (HOCs) and heavy metals from an electronic waste (e-waste) site. Ultrasonically aided mixing of the field contaminated soil with a combination of MCD and TS solutions simultaneously mobilizes most of polybrominated diphenyl ethers (PBDEs), polychlorinated biphenyls (PCBs), polycyclic aromatic hydrocarbons (PAHs), and the analyte metal (Pb, Cu, and Ni) burdens. It is found that 15 g/L MCD and 10 g/L TS is an efficient reagent combination reconciling extraction performance and reagent costs. Under these conditions, the removal efficiencies of HOCs and heavy metals are 93.5 and 91.2 %, respectively, after 2 cycles of 60-min ultrasound-assisted washing cycles. By contrast, 86.3 % of HOCs and 88.4 % of metals are removed from the soil in the absence of ultrasound after 3 cycles of 120-min washing. The ultrasound-assisted soil washing could generate high removal efficiency and decrease the operating time significantly. Finally, the feasibility of regenerating and reusing the spent washing solution in extracting pollutants from the soil is also demonstrated. By application of this integrated technology, it is possible to recycle the washing solution for a purpose to reduce the consumption of surfactant solutions. Collectively, it has provided an effective and economic treatment of e-waste-polluted soil.

  15. The Development of Treatment Process Technology for Uranium Soil washing Leachate

    Energy Technology Data Exchange (ETDEWEB)

    Shon, Dong Bin; Kim, Gye Nam; Park, Hye Min; Kim, Ki Hong; Lee, Ki Won; Moon, Jeik won [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2011-05-15

    Electrokinetic treatment technology is a good method for removing radioactive substances such as U, Co, Cs: but it has a weakness. It takes a long time to get high removal efficiency. The Soil washing method compensates for this weak point with its short reaction time and with this method it is possible to remove a lot of uranium-contaminated soil. But a great deal of leachate is generated. That is, about more amounts of leachate are generated for the decontamination of the same volume of radioactive soil using the electrokinetic equipment. Therefore, the development of a treatment process for The Soil washing leachate is important so that there is a reduction of leachate waste volume and a choice of process. Previously, studies for liquid radioactive waste were in process at various nuclear facilities. Nuclear fuel plant survey appropriate cohesion quantity of liquid waste of radioactive. Nuclear power plants manage liquid radioactive waste with centrifugation equipment. In this study, the treatment technology for uranium Soil washing leachate generated on Soil washing decontamination for the soil contaminated with uranium was developed. A treatment process suitable to the contamination characteristics of Soil washing leachate was proposed

  16. 100 Area soil washing bench-scale test procedures

    International Nuclear Information System (INIS)

    Freeman, H.D.; Gerber, M.A.; Mattigod, S.V.; Serne, R.J.

    1993-03-01

    This document describes methodologies and procedures for conducting soil washing treatability tests in accordance with the 100 Area Soil Washing Treatability Test Plan (DOE-RL 1992, Draft A). The objective of this treatability study is to evaluate the use of physical separation systems and chemical extraction methods as a means of separating chemically and radioactively contaminated soil fractions from uncontaminated soil fractions. These data will be primarily used for determining feasibility of the individual unit operations and defining the requirements for a system, or systems, for pilot-scale testing

  17. Centrifugation-free washing: A novel approach for removing immunoglobulin A from stored red blood cells.

    Science.gov (United States)

    Vörös, Eszter; Piety, Nathaniel Z; Strachan, Briony C; Lu, Madeleine; Shevkoplyas, Sergey S

    2018-08-01

    Washed red blood cells (RBCs) are indicated for immunoglobulin A (IgA) deficient recipients. Centrifugation-based cell processors commonly used by hospital blood banks cannot consistently reduce IgA below the recommended levels, hence double washing is frequently required. Here, we describe a prototype of a simple, portable, disposable system capable of washing stored RBCs without centrifugation, while reducing IgA below 0.05 mg/dL in a single run. Samples from RBC units (n = 8, leukoreduced, 4-6 weeks storage duration) were diluted with normal saline to a hematocrit of 10%, and then washed using either the prototype washing system, or via conventional centrifugation. The efficiency of the two washing methods was quantified and compared by measuring several key in vitro quality metrics. The prototype of the washing system was able to process stored RBCs at a rate of 300 mL/hour, producing a suspension of washed RBCs with 43 ± 3% hematocrit and 86 ± 7% cell recovery. Overall, the two washing methods performed similarly for most measured parameters, lowering the concentration of free hemoglobin by >4-fold and total free protein by >10-fold. Importantly, the new washing system reduced the IgA level to 0.02 ± 0.01 mg/mL, a concentration 5-fold lower than that produced by conventional centrifugation. This proof-of-concept study showed that centrifugation may be unnecessary for washing stored RBCs. A simple, disposable, centrifugation-free washing system could be particularly useful in smaller medical facilities and resource limited settings that may lack access to centrifugation-based cell processors. © 2017 Wiley Periodicals, Inc.

  18. Design of full scale debris washing system

    International Nuclear Information System (INIS)

    Taylor, M.L.; Dosani, M.A.; Wentz, J.A.; Patkar, A.N.; Barkley, N.P.

    1992-01-01

    Since 1987, IT Environmental Programs Inc. (ITEP, a subsidiary of International Technology Corporation) in conjunction with EPA/RREL in Cincinnati, Ohio, have been developing and conducting bench scale and pilot scale testing of a transportable debris washing system which can be used on-site for the decontamination of debris. During the initial phase of the debris decontamination project, a series of bench scale tests were performed in the laboratory to assess the ability of the system to remove contaminants from debris and to facilitate selection of the most efficient surfactant solution. Five nonionic, non-toxic, low foaming, surfactant solution (BG-5, MC-2000, LF-330, BB-100, and L-433) were selected for an experimental evaluation to determine their capacity to solubilize and remove contaminants from the surfaces of corroded steel places. The pieces of corroded steel were coated with a heavy grease mixture prepared in the laboratory and these pieces of debris were placed in a bench scale spray tank on a metal tray and subjected in a high-pressure spray for each surfactant solution for 15 minutes. At the end of the spray cycle, The tray was transferred to a second bench scale system, a high-turbulence wash tank, where the debris was washed for 30 minutes with the same surfactant solution as the used in the spray tank. After the was cycle was completed, the tray was removed from the wash tank and the debris was allowed to air-dry. Before and after treatment, surface-wipe samples were obtained from each of the six pieces of debris and were analyzed for oil and graese. Based on the results, BG-5 was selected as the solution best suited for cleaning grease-laden, metallic debris. 2 refs

  19. Understanding road surface pollutant wash-off and underlying physical processes using simulated rainfall.

    Science.gov (United States)

    Egodawatta, Prasanna; Goonetilleke, Ashantha

    2008-01-01

    Pollutant wash-off is one of the key pollutant processes that detailed knowledge is required in order to develop successful treatment design strategies for urban stormwater. Unfortunately, current knowledge relating to pollutant wash-off is limited. This paper presents the outcomes of a detailed investigation into pollutant wash-off on residential road surfaces. The investigations consisted of research methodologies formulated to overcome the physical constraints due to the heterogeneity of urban paved surfaces and the dependency on naturally occurring rainfall. This entailed the use of small road surface plots and artificially simulated rainfall. Road surfaces were selected due to its critical importance as an urban stormwater pollutant source. The study results showed that the influence of initially available pollutants on the wash-off process was limited. Furthermore, pollutant wash-off from road surfaces can be replicated using an exponential equation. However, the typical version of the exponential wash-off equation needs to be modified by introducing a non dimensional factor referred to as 'capacity factor' CF. Three rainfall intensity ranges were identified where the variation of CF can be defined. Furthermore, it was found that particulate density rather than size is the critical parameter that influences the process of pollutant wash-off. (c) IWA Publishing 2008.

  20. Wireless sensors cut costs of well monitoring in Nigerian swamps[Nigeria

    Energy Technology Data Exchange (ETDEWEB)

    Fasasi, Toyin; Maynard, Don; Nasr, Hatem; Patwari, Rajesh; Mashetti, Srikanth

    2005-07-01

    The article presents a pilot installation at the Kambo oil field in Nigeria that employs two-way wireless communication devices for long-range monitoring of production wells and facilities. Some management and technical aspects are mentioned.

  1. An overview of the Department of Energy's soil washing workshop

    International Nuclear Information System (INIS)

    1991-09-01

    The Soil Washing Workshop was convened in Las Vegas, Nevada, on August 28--29, 1990 at the request of C.W. Frank, Associate Director, Office of Technology Development, US Department of Energy (DOE). The purpose of the workshop was to determine the status of existing soil washing technologies and their applicability to specific soil contamination problems at DOE sites and at Superfund sites of the US Environmental Protection Agency (EPA). From the workshop deliberations, a course of action would be recommended in developing soil washing technologies. Presentations were given describing the soil contamination problems at various DOE sites. The factors addressed for each site included: type of contamination (organic, heavy metals, radionuclides, etc.), sources of contamination (leaking tanks, ponds, soil columns, pipes, etc.), types of soils that are contaminated, magnitude of the problem, current site activities (remediation), other considerations that impact the use of soil washing technology (e.g., environmental, site policies, etc.), and regulations and standards the sites are required to meet. Major findings and presentations of the workshop are presented

  2. Soil washing results for mixed waste pond soils at Hanford

    International Nuclear Information System (INIS)

    Gerber, M.A.

    1991-09-01

    Soil washing technology was assessed as a means for remediating soil contaminated with mixed wastes primarily composed of heavy metals and radionuclides. The soils at the US Department of Energy's Hanford Site are considered suitable for soil washing because of their relatively low quantities of silt and clay. However, in a limited number of soil washing experiments using soils from different locations in the north pond of the 300 Area, the degree of decontamination achieved for the coarse fraction of the soil varied considerably. Part of this variation appears to be due to the presence of a discrete layer of contaminated sediment found in some of the samples. 7 refs., 2 figs., 4 tabs

  3. Mothers’ Hand washing Practice and Diarrhea Cases in Children under Five in Baleendah, Bandung

    Directory of Open Access Journals (Sweden)

    M Syafril Firdaus

    2015-06-01

    Full Text Available ackground: Diarrhea is a disease, especially in children, with high mortality and morbidity rate in developing countries, including Indonesia. Diarrhea can be prevented if people can apply clean and healthy behaviors, especially hand washing. Hand washing is the cheapest, simplest, and the most effective methods for prevention of diarrhea. The objective of this study is to identify the knowledge, attitude, and practice of mothers’ hand washing and diarrhea cases in children under five in Baleendah District, Bandung. Methods: A descriptive study was conducted during September−November 2012 to 210 mothers who had children (ages 12−59 months in Baleendah using rapid survey technique. The time allocated for each village was adjusted to the population proportion for each region. The data were analyzed using computer and was represented using frequency distribution. Results: This study showed that the respondents had good level of knowledge and attitude of hand washing (83.8% and 61%, respectively, but only 21% of the respondents’ practices of hand washing was in good level. Most of the respondents did not wash their hands according to the 7 steps of correct hand washing. Moreover the percentage of children with diarrhea in Baleendah was 43.8% (92 cases during the study. Conclusions: There should be dissemination of information about the benefit of washing hands with 7 steps of correct hands washing so that families can practice it and can prevent diarrhea in children under five.

  4. Membrane processes for the reuse of car washing wastewater

    OpenAIRE

    Deniz Uçar

    2018-01-01

    This study investigates alternative treatments of car wash effluents. The car wash wastewater was treated by settling, filtration, and membrane filtration processes. During settling, total solid concentration decreased rapidly within the first 2 hours and then remained constant. Chemical oxygen demand (COD) and conductivity were decreased by 10% and 4%, respectively. After settling, wastewater was filtered throughout a 100 μm filter. It was found that filtration had a negligible effect on COD...

  5. Effect of different soil washing solutions on bioavailability of residual arsenic in soils and soil properties.

    Science.gov (United States)

    Im, Jinwoo; Yang, Kyung; Jho, Eun Hea; Nam, Kyoungphile

    2015-11-01

    The effect of soil washing used for arsenic (As)-contaminated soil remediation on soil properties and bioavailability of residual As in soil is receiving increasing attention due to increasing interest in conserving soil qualities after remediation. This study investigates the effect of different washing solutions on bioavailability of residual As in soils and soil properties after soil washing. Regardless of washing solutions, the sequential extraction revealed that the residual As concentrations and the amount of readily labile As in soils were reduced after soil washing. However, the bioassay tests showed that the washed soils exhibited ecotoxicological effects - lower seed germination, shoot growth, and enzyme activities - and this could largely be attributed to the acidic pH and/or excessive nutrient contents of the washed soils depending on washing solutions. Overall, this study showed that treated soils having lower levels of contaminants could still exhibit toxic effects due to changes in soil properties, which highly depended on washing solutions. This study also emphasizes that data on the As concentrations, the soil properties, and the ecotoxicological effects are necessary to properly manage the washed soils for reuses. The results of this study can, thus, be utilized to select proper post-treatment techniques for the washed soils. Copyright © 2015 Elsevier Ltd. All rights reserved.

  6. The integration of innovative technologies into a physical-separation-based soil washing system

    International Nuclear Information System (INIS)

    Krstich, M.A.

    1995-01-01

    An innovative system's approach to the treatment of soils at the Fernald Environmental Management Project (FEMP) has been proposed to effectively and cost competitively treat a significant mass of soil. The use of an integrated soil treatment system to decontaminate FEMP soils is a unique application of the soil washing technology. Due to the unfavorable soil particle size distribution and the ubiquitous distribution of uranium among these particle size fractions, conventional soil washing processes commonly used on predominantly sandy soils alone may not achieve the desirable waste minimization level without the inclusion of innovative technologies. This objective of this paper is to briefly describe the physical separation and chemical extraction process commonly used in soil washing operation and to present the baseline soil washing approach used on FEMP soils. Noting the successful and not-so-successful processes within the soil washing operation at the FEMP, a proposed innovative system's approach to treating FEMP soils will be described. This system's approach will integrate a conventional soil washing operation with proposed innovative technologies

  7. Road surface washing system for decontaminating radioactive substances. Experiment of radioactive decontamination

    International Nuclear Information System (INIS)

    Endo, Mitsuru; Endo, Mai; Kakizaki, Takao

    2015-01-01

    The Great East Japan Earthquake that occurred on March 11, 2011 resulted in the explosion of the TEPCO Fukushima 1st Nuclear Power Plant and the global dispersion of a large quantity of radioactive substances. A high radiation dose was particularly recorded in Fukushima prefecture several weeks after the accident, although the level is presently sufficiently low. However, considering that the adverse effects of low but extended exposure to radiation are yet to be negated, there is the urgent need for further decontamination. In our study, we focused on the efficient decontamination of radioactive substances in residential areas, for which we propose a high-pressure water jet system for washing road surfaces. The system differs from conventional systems of its type that were initially designed for use in the immediate environment of the nuclear reactors of the TEPCO Fukushima 1st Nuclear Power Plant. The proposed system consists of multiple washing, transporter, and server robots. The washing robots decontaminate the road surface using high-pressure water jets and are transported between washed and unwashed areas by the transporter robots. The server robots supply the water used for washing and absorb the polluted water together with ground dust. In this paper, we describe the concept of the system and present the results of decontamination experiments. Particular attention is given to the washing robot and its mechanism and control method. The results of the integration of the washing robot in an experimental system confirmed the feasibility of the proposed system. (author)

  8. Evaluation of genotoxicity of liquid effluents from gas washing systems by means of bioassay Trad-MCN

    International Nuclear Information System (INIS)

    Machado, Alessandra Carla Fattori Ergesse; Alves, Edenise Segala

    2007-01-01

    In the gas washing systems the gaseous emissions from a facility are forced through an absorbing liquid preventing pollutants to be dispersed into the atmosphere. In the Centro Tecnologico da Marinha em Sao Paulo/Centro Experimental Aramar (CEA), the gas washing are used to control the emissions from the uranium enrichment facilities. Uranium. fluoride, ammonia and hydrogen fluoride are the main contaminants, all heavily toxic. Biological assays, using plants or other living organisms, have been used to assess genotoxic agents in the environment. Among the bioassays using plants, the Trad-MCN has been used extensively, as it allows the evaluation of liquid or gaseous contaminants. The species Tradescantia pallida (Rose) was exposed in a dynamic system to liquid effluents from CEA. A positive control was the exposure to formaldehyde 10% in water, known as a very toxic solution, and the negative control was the exposure to filtered air. The protocol established by Ma (1983) for hybrid clones and validated for the T. pallida by Guimaraes (2003) was used to perform the Trad-MCN assays. Only preparations containing early tetrads were scored. In that context, the present study objectifies to evaluate, by the Trad-MCN bioassay, the genotoxicity of the solution from the gas washing and, also, evaluate the efficiency of that system. The results obtained show that the T. pallida is a sensitive bioindicator for the pollutants tested and can be useful for in vitro environmental monitoring under controlled conditions. (author)

  9. Evaluation of genotoxicity of liquid effluents from gas washing systems by means of bioassay Trad-MCN

    Energy Technology Data Exchange (ETDEWEB)

    Machado, Alessandra Carla Fattori Ergesse [Centro Tecnologico da Marinha em Sao Paulo (CTMSP), SP (Brazil). Div. de Monitoracao Ambiental], E-mail: alessandra@ctmsp.mar.mil.br; Alves, Edenise Segala [Instituto de Botanica de Sao Paulo, SP (Brazil). Secao de Anatomia], E-mail: ealves@ibot.sp.gov.br

    2007-07-01

    In the gas washing systems the gaseous emissions from a facility are forced through an absorbing liquid preventing pollutants to be dispersed into the atmosphere. In the Centro Tecnologico da Marinha em Sao Paulo/Centro Experimental Aramar (CEA), the gas washing are used to control the emissions from the uranium enrichment facilities. Uranium. fluoride, ammonia and hydrogen fluoride are the main contaminants, all heavily toxic. Biological assays, using plants or other living organisms, have been used to assess genotoxic agents in the environment. Among the bioassays using plants, the Trad-MCN has been used extensively, as it allows the evaluation of liquid or gaseous contaminants. The species Tradescantia pallida (Rose) was exposed in a dynamic system to liquid effluents from CEA. A positive control was the exposure to formaldehyde 10% in water, known as a very toxic solution, and the negative control was the exposure to filtered air. The protocol established by Ma (1983) for hybrid clones and validated for the T. pallida by Guimaraes (2003) was used to perform the Trad-MCN assays. Only preparations containing early tetrads were scored. In that context, the present study objectifies to evaluate, by the Trad-MCN bioassay, the genotoxicity of the solution from the gas washing and, also, evaluate the efficiency of that system. The results obtained show that the T. pallida is a sensitive bioindicator for the pollutants tested and can be useful for in vitro environmental monitoring under controlled conditions. (author)

  10. Oxidation of lipid and protein in horse mackerel (Trachurus trachurus) mince and washed minces during processing and storage

    DEFF Research Database (Denmark)

    Eymard, Sylvie; Baron, Caroline; Jacobsen, Charlotte

    2009-01-01

    : M1, M2 and M3, with one, two and three washing steps, respectively. The different products were characterised (i.e. lipid content, protein, water, iron, fatty acid profile and tocopherol content) and analysed for protein and lipid oxidation in order to investigate the impact of the washing steps...... was followed by determination of protein solubility, protein thiol groups and protein carbonyl groups using colorimetric methods as well as western blotting for protein carbonyl groups. Lipid and protein oxidation markers indicated that both lipid and protein oxidation took place during processing...

  11. A case study of optimization in the decision process: Siting groundwater monitoring wells

    International Nuclear Information System (INIS)

    Cardwell, H.; Huff, D.; Douthitt, J.; Sale, M.

    1993-12-01

    Optimization is one of the tools available to assist decision makers in balancing multiple objectives and concerns. In a case study of the siting decision for groundwater monitoring wells, we look at the influence of the optimization models on the decisions made by the responsible groundwater specialist. This paper presents a multi-objective integer programming model for determining the location of monitoring wells associated with a groundwater pump-and-treat remediation. After presenting the initial optimization results, we analyze the actual decision and revise the model to incorporate elements of the problem that were later identified as important in the decision-making process. The results of a revised model are compared to the actual siting plans, the recommendations from the initial optimization runs, and the initial monitoring network proposed by the decision maker

  12. Basic Data Report for Monitor Well AEC-7 (C-2742) Reconfiguration Activities

    International Nuclear Information System (INIS)

    2005-01-01

    The New Mexico Office of the State Engineer (OSE) permitted well AEC-7 as C-2742. This well has been part of the far-field monitoring network since 1974. The well was used to obtain water level elevations and hydraulic parameters from both the Bell Canyon Formation and the Culebra Member of the Rustler Formation. This basic data report provides a historical account of the well from the original installation to the current configuration.

  13. Washing of gel particles in wet chemical manufacture of reactor fuel particles

    International Nuclear Information System (INIS)

    Ringel, H.

    1980-07-01

    In the manufacture of HTR fuel particles and particles of fertile material by wet chemical methods, the ammonium nitrate formed during the precipitation reaction must be washed out of the gel particles. This washing process has been investigated theoretically and experimentally. A counter-current washer has been developed which in particular takes account of the aspects of refabrication - such as compact construction and minimum waste. A counter-current washing column of 17 mm internal diameter and 640 mm length gives to gel particle throughput of 0.65 1/h. The volume ratio of wash water to gel particles is 5, and the residual nitrate concentration in the particles is 7 x 10 -3 mols of NO - 3 /1. (orig.) [de

  14. Pseudohyperglycemia: Effects of Unwashed Hand after Fruit Peeling or Handling on Fingertips Blood Glucose Monitoring Results.

    Science.gov (United States)

    Olamoyegun, M A; Oloyede, T; Adewoye, O G; Abdulkarim, S O; Adeleke, A A

    2016-01-01

    Self-monitoring of blood glucose (SMBG) is an important component of management for diabetes mellitus (DM), especially in T1DM and T2DM patients who are on insulin therapy. Adequate blood glucose monitoring and prompt intervention are necessary to prevent blood glucose (BG) fluctuation and delay long-term diabetes complications. People with DM are advised to clean their hands before SMBG to remove any dirt or food residue that might affect the reading. The study tested the hypothesis that falsely elevated BG levels from fingertip occur after peeling or handling fruits in an unwashed hand. Fifty apparently healthy nondiabetes volunteers were enrolled. Capillary BG samples were collected from the fingertips after peeling or handling apple, orange, banana, watermelon, and pawpaw, followed by no hand washing for 1 h, cleaning the fingertip with alcohol swab once, five times, and washing hand thoroughly with tap water and drying. These samples were then analyzed with two different glucose meters. The mean BG values, measured from fingertip blood samples after peeling, and handling any of the fruits followed by no hand washing were significantly high, even after cleaning fingertip with a swab of alcohol once. However, there were no significant difference in BG levels measured after peeling and handling fruits followed by hand washing and the level of BG before peeling and handling fruits. Handling of peeled fruits with no hand washing with tap water is associated with overestimation of capillary BG (Pseudohyperglycemia) monitored with glucose meters.

  15. Use of direct washing of chemical dispense nozzle for defect control

    Science.gov (United States)

    Linnane, Michael; Mack, George; Longstaff, Christopher; Winter, Thomas

    2006-03-01

    Demands for continued defect reduction in 300mm IC manufacturing are driving process engineers to examine all aspects of the chemical apply process for improvement. Historically, the defect contribution from photoresist apply nozzles has been minimized through a carefully controlled process of "dummy dispenses" to keep the photoresist in the tip "fresh" and remove any solidified material, a preventive maintenance regime involving periodic cleaning or replacing of the nozzles, and reliance on a pool of solvent within the nozzle storage block to keep the photoresist from solidifying at the nozzle tip. The industry standard has worked well for the most part but has limitations in terms of cost effectiveness and absolute defect elimination. In this study, we investigate the direct washing of the chemical apply nozzle to reduce defects seen on the coated wafer. Data is presented on how the direct washing of the chemical dispense nozzle can be used to reduce coating related defects, reduce material costs from the reduction of "dummy dispense", and can reduce equipment downtime related to nozzle cleaning or replacement.

  16. Computer Simulation of Bound Component Washing To Minimize Processing Costs

    Directory of Open Access Journals (Sweden)

    Dagmar Janáčová

    2011-11-01

    Full Text Available In this paper we focused on the optimization of the washing processes because many technological processes are characterizedby large consumption of water, electrical energy and auxiliary chemicals mainly. For this reason it is very important to deal withthem. For the optimization of process of washing it is possible to set up an access of the indirect modeling that is based on make-up ofmathematical models coming out of study of the physical operation mechanism. The process is diffusion character it is characterizedby the value of diffusion effective coefficient and so called structure power of the removing item to the solid phase. The mentionedparameters belong to input data that are appropriate for the automatic control of washing process.

  17. Washing Habits and Machine with Intake of hot and cold Water

    DEFF Research Database (Denmark)

    Christensen, Bente Lis; Nørgaard, Jørgen

    1997-01-01

    with slightly adapted washing habits, or 17% of normal today. If the heat is supplied from combined heat and power production as in the actual experiment, CO2-emission is reduced by 81%. With hot water from oil or gas heaters the reduction will be slightly lower, while with solar hot water it will be larger.......Domestic washing machines typically spend around 80% of the electricity on heating water. Most of this can be replaced by more appropriate heat sources like district heat from combined heat and power production, or gas heating system. In recent years some washing machine manufacturers have marketed...... machines which can take in both hot and cold water and mix it to the temperature wanted. Such one machine has been tested in daily household use over 5 months, with habits of very few hot water washes. The result is an electricity consumption corresponding to 67 kWh per year for an average household...

  18. Semen quality parameters, their inter-relationship and post-washing sperm attributes of Rhode Island Red roosters

    Directory of Open Access Journals (Sweden)

    R. Richard Churchil

    2014-12-01

    Full Text Available Aim: The present experiments were conducted (a to evaluate the semen attributes of older Rhode Island Red (RIR roosters and the inter-trait relationships, (b to test sperm washing and storage duration suitable for gene transfer experiments. Materials and Methods: The semen characteristics of older RIR roosters were studied, and Pearson correlation analysis was done to demonstrate the inter-trait relationships. Progressive motility and percent live sperms were tested at different post-washing intervals to identify suitable sperm processing conditions for gene transfer experiments. Results: The volume, appearance score, initial motility, sperm count and percent live and abnormal spermatozoa were 0.38 ml, 3.58, 80.34%, 4.03 × 109 sperms/ml, 83.18% and 4.52% respectively. Positive correlation was observed among appearance score, motility, live sperm and sperm count. Semen volume is negatively correlated with all the other characters except live sperms, whereas, percent abnormal sperms negatively associated with all the other traits. Significant (p<0.05 decrease in terms of motility and live sperm was recorded at 60 min post-washing. Conclusion: The semen attributes of RIR roosters compares well with the other breeds of chicken. The appearance score can be used to assess fertility where microscopic evaluation facilities are limited. The sperm washing protocol tested in the experiment is suitable for gene transfer experiments.

  19. Effect of exhaust emissions on carbon monoxide levels in employees working at indoor car wash facilities.

    Science.gov (United States)

    Topacoglu, H; Katsakoglou, S; Ipekci, A

    2014-01-01

    Exhaust emissions from motor vehicles threaten the environment and human health. Carbon monoxide (CO) poisoning, especially the use of exhaust gas CO in suicidal attempts is well known in the literature. Recently, indoor car wash facilities established in large shopping malls with closed parking, lots is a new risk area that exposes car wash employees to prolonged periods of high level CO emissions from cars. The aim of this study was to investigate how carboxyhemoglobin (COHb) blood levels of employees get affected in confined areas with relatively poor air circulation. Twenty male volunteers working in indoor parking car wash facilities were included in the study. Participants were informed about the aim of this study and their consent was obtained. Their pulse COHb levels were measured twice, at the beginning and at the end of the working day using Rad-57 pulse CO-oximeter device, allowing non-invasive measurement of COHb blood levels to compare the changes in their COHb levels before and after work. The mean age of the male volunteers was 29.8 ± 11.9 (range 18-55). While the mean COHb levels measured at the start of the working day was 2.1 ± 2.0 (range 0-9), it was increased to 5.2 ± 3.3 (range 1-15) at the end of work shift (Wilcoxon test, p car wash facility employees is directly impacted and gets elevated by motor vechile exhaust emissions. For the health of the employees at indoor parking car wash facilities, stricter precautions are needed and the government should not give permit to such operations.

  20. 40 CFR 446.10 - Applicability; description of the oil-base solvent wash paint subcategory.

    Science.gov (United States)

    2010-07-01

    ...-base solvent wash paint subcategory. 446.10 Section 446.10 Protection of Environment ENVIRONMENTAL...-Base Solvent Wash Paint Subcategory § 446.10 Applicability; description of the oil-base solvent wash... production of oil-base paint where the tank cleaning is performed using solvents. When a plant is subject to...

  1. Purification of crude biodiesel using dry washing and membrane technologies

    OpenAIRE

    Atadashi, I.M.

    2015-01-01

    Purification of crude biodiesel is mandatory for the fuel to meet the strict international standard specifications for biodiesel. Therefore, this paper carefully analyzed recently published literatures which deal with the purification of biodiesel. As such, dry washing technologies and the most recent membrane biodiesel purification process have been thoroughly examined. Although purification of biodiesel using dry washing process involving magnesol and ion exchange resins provides high-quali...

  2. Improving understanding of the underlying physical process of sediment wash-off from urban road surfaces

    Science.gov (United States)

    Muthusamy, Manoranjan; Tait, Simon; Schellart, Alma; Beg, Md Nazmul Azim; Carvalho, Rita F.; de Lima, João L. M. P.

    2018-02-01

    Among the urban aquatic pollutants, the most common is sediment which also acts as a transport medium for many contaminants. Hence there is an increasing interest in being able to better predict the sediment wash-off from urban surfaces. The exponential wash-off model is the most widely used method to predict the sediment wash-off. Although a number of studies proposed various modifications to the original exponential wash-off equation, these studies mostly looked into one parameter in isolation thereby ignoring the interactions between the parameters corresponding to rainfall, catchment and sediment characteristics. Hence in this study we aim (a) to investigate the effect of rainfall intensity, surface slope and initial load on wash-off load in an integrated and systematic way and (b) to subsequently improve the exponential wash-off equation focusing on the effect of the aforementioned three parameters. A series of laboratory experiments were carried out in a full-scale setup, comprising of a rainfall simulator, a 1 m2 bituminous road surface, and a continuous wash-off measuring system. Five rainfall intensities ranging from 33 to 155 mm/h, four slopes ranging from 2 to 16% and three initial loads ranging from 50 to 200 g/m2 were selected based on values obtained from the literature. Fine sediment with a size range of 300-600 μm was used for all of the tests. Each test was carried out for one hour with at least 9 wash-off samples per test collected. Mass balance checks were carried out for all the tests as a quality control measure to make sure that there is no significant loss of sand during the tests. Results show that the washed off sediment load at any given time is proportional to initial load for a given combination of rainfall intensity and surface slope. This indicates the importance of dedicated modelling of build-up so as to subsequently predict wash-off load. It was also observed that the maximum fraction that is washed off from the surface increases

  3. Granulometric data 241-U tank farm monitoring well sediments

    International Nuclear Information System (INIS)

    Fecht, K.R.; Price, W.H.

    1977-12-01

    This report documents the quantitative analysis of disaggregated grains according to a grain size grouping scheme, termed herein granulometric analysis. The sediments analyzed were collected during the drilling of monitoring wells in the 241-U Tank Farm and were utilized to prepare a series of geologic maps and cross sections. The relative proportions of different sediment size fractions found in the sediments underlying the tank farm are important for the purposes of: (1) defining the relationships of various sediment types, (2) developing approximations of engineering and hydrological properties of sediments, and (3) determining sedimentary genesis. Approximately 790 sediment samples in the 241-U Tank Farm were analyzed for grain size with disaggregated intermediate diameters ranging from 64 to 0.063 millimeters. Size analysis was conducted utilizing a nest of nine screens with wire mesh size openings coinciding to the Wentworth-grade scale divisions. The granulometric data were input to a computer program (ROC) to categorize sediment samples into one of nineteen disaggregated sediment classes. Also included in ROC are calcium carbonate data which were determined by a semiquantitative carbon dioxide displacement method. A discussion of drilling and sampling methods, grain size nomenclature, sediment classification, sieving, calcium carbonate analysis, ROC computer program, and procedures is included to aid in understanding granulometric analysis. The background discussion is followed by the granulometric data from 241-U Tank Farm monitoring well sediment samples

  4. Washing of Uranium Gel Resulted from Gelation Using Ammonia

    International Nuclear Information System (INIS)

    Nurwijayadi; Bangun-Wasito; Sukarsono; Endang-Nawangsih

    2000-01-01

    Washing of uranium gel resulted from gelation using ammonia underconcentration of 1, 2.5, 3, 4 and 5 % has been carried out. The sol wasprepared by reacting uranyl nitrate, urea and HMTA at 5 o C. The resulted solwas dropped into a column containing paraffin oil at temperature of 95 o C.The resulted gel color was orange. It was simmered in a 2.5 % ammoniasolution for 24 hours. After that, the gel was washed in an ammonia solutionunder a concentration variation. The best washing process occurred at ammoniaconcentration of 2.5 % with most absorbed ion nitrate, i.e. 292.2 ppm. Theresulted true density using N 2 was about 8.3 - 8.6 g/ml, specific surfacearea using multi point BET was about 1.5 - 3.1 m 2 /g, average pore radius was22.27 -41.22 A and total pore volume was 3.55 x 10 -3 cc/g. (author)

  5. Dichlorvos (DDVP residue removal from tomato by washing with tap and ozone water, a commercial detergent solution and ultrasonic cleaner

    Directory of Open Access Journals (Sweden)

    Ali HESHMATI

    Full Text Available Abstract Dichlorvos (DDVP is one of the most consumption chlorinated organophosphate insecticide used on tomato. The knowledge about the influence of postharvest household processes on the levels of DDVP residues in vegetables is required to estimate dietary exposure. In this study, the removal of sprayed dichlorvos (DDVP on tomato by washing with tap, ozonated water (in dosages of 2, 4 and 6 mg ozone/L, a commercial detergent solution (in concentration of 1, 2 and 3% and ultrasonic cleaner (with power of 100, 200 and 300 W was investigated. DDVP residue was determined by gas chromatography with electron capture detector. Washing processes led to the significant reduction of DDVP. The gradual increase in the percentage of the removal was observed due to increment of washing time, ozone dosage, and concentration of detergent solution as well as ultrasonic power. The maximum removal percentage of DDVP after 15 min of washing with tap and ozonated water, a detergent solution and ultrasonic cleaner was 30.7, 91.9, 70.7, and 88.9%, respectively. In general, results indicated washing with tap, ozonated water, a detergent solution and ultrasonic cleaning are effective methods for removal of DDVP from tomato and reduction of its dietary exposure without influence on product quality.

  6. Performance of a Small-scale Treatment Wetland for Treatment of Landscaping Wash Water

    Science.gov (United States)

    Thompson, R. J.; Fayed, E.; Fish, W.

    2011-12-01

    A large number of lawn mowers and related equipment must be cleaned each day by commercial landscaping operations and state and local highway maintenance crews. Washing these devices produces wastewater that contains high amounts of organic matter and potentially problematic nutrients, as well as oil and grease and other chemicals and metals that come from the machinery itself. Dirty water washes off the mowers, flows off the pavement and into nearby storm drains without any kind of treatment. A better idea would be to collect such wastewater, retain it in an appropriate catchment such as an engineered wetland where natural processes could break down any pollutants in the wash water, and allow the water to naturally evaporate or percolate into the soil where it could recharge ground water resources safely. This research examines the performance of a small-scale treatment wetland tailored to remove nitrogen from landscaping wash water by incorporating both aerobic and anaerobic phases. Contaminants are analyzed through physical and chemical methods. Both methods involve collection of samples, followed by standardized, validated analytical laboratory tests for measuring total solids, total kjeldahl nitrogen, nitrates, total and dissolved phosphorus, COD, BOD, oil and grease, and metals (Zn and Cu). High levels of total solids, total kjeldahl nitrogen, nitrates, total and dissolved phosphorus, COD, BOD, oil and grease are found. Zinc and copper levels are low. Wetland treatment removes 99% total solids, 77% total kjeldahl nitrogen, 100% nitrates, 94% total phosphorus, 86% dissolved phosphorus, 94% COD, 97% BOD, and 76% oil and grease. The results will be a critical step towards developing a sustainable low-energy system for treating such wastewater that could be used by private landscaping companies and government agencies.

  7. Study Effect of Salt Washing Process on Content and Iodium Stability of Salt

    Directory of Open Access Journals (Sweden)

    Nelson Saksono

    2010-10-01

    Full Text Available Effect of Salt Washing Process on Content and Iodium Stability of Salt. Salt washing process should increase the saltquality. It should clean the salt from sludge or clay and also reduce the impurity compound such as Mg, Ca and the reductor content. The objective of these reseach is to assess the effect of washing process on the content og hygroscopic impurities compound (Ca and Mg, and reductor content of salt. The research also investigate the water absorbing, pH, KIO3 content as function of time to obtain effect of washing process on KIO3 stability in salt. The experiment result shows that the lowest content of Mg and reductor compound 0.016 % wt and 2.65 ppm respectively which is reached at the fi ne salt washing process using 27 % wt brine. The analysis of water content indicates an increase the Ca and Mg content, causing an water absorbtion in salt , However the effect on pH the is not clear.

  8. Set-up for steam generator tube bundle washing after explosion expanding the tubes

    International Nuclear Information System (INIS)

    Osipov, S.I.; Kal'nin, A.Ya.; Mazanenko, M.F.

    1985-01-01

    Set-up for steam generator tube bundle washing after the explosion expanding of tubes is described. Washing is accomplished by distillate. Steam is added to distillate for heating, and compersed air for preventing hydraulic shock. The set-up is equiped by control equipment. Set-up performances are presented. Time for one steam generator washing constitutes 8-12 h. High economic efficiency is realized due to the set-up introduction

  9. Real-time well condition monitoring in extended reach wells

    Energy Technology Data Exchange (ETDEWEB)

    Kucs, R.; Spoerker, H.F. [OMV Austria Exploration and Production GmbH, Gaenserndorf (Austria); Thonhauser, G. [Montanuniversitaet Leoben (Austria)

    2008-10-23

    Ever rising daily operating cost for offshore operations make the risk of running into drilling problems due to torque and drag developments in extended reach applications a growing concern. One option to reduce cost related to torque and drag problems can be to monitor torque and drag trends in real time without additional workload on the platform drilling team. To evaluate observed torque or drag trends it is necessary to automatically recognize operations and to have a 'standard value' to compare the measurements to. The presented systematic approach features both options - fully automated operations recognition and real time analysis. Trends can be discussed between rig- and shore-based teams, and decisions can be based on up to date information. Since the system is focused on visualization of real-time torque and drag trends, instead of highly complex and repeated simulations, calculation time is reduced by comparing the real-time rig data against predictions imported from a commercial drilling engineering application. The system allows reacting to emerging stuck pipe situations or developing cuttings beds long before the situations become severe enough to result in substantial lost time. The ability to compare real-time data with historical data from the same or other wells makes the system a valuable tool in supporting a learning organization. The system has been developed in a joint research initiative for field application on the development of an offshore heavy oil field in New Zealand. (orig.)

  10. GE/NOMADICS IN-WELL MONITORING SYSTEM FOR VERTICAL PROFILING OF DNAPL CONTAMINANTS

    Energy Technology Data Exchange (ETDEWEB)

    Ronald E. Shaffer; Radislav Potyralio; Joseph Salvo; Timothy Sivavec; Lloyd Salsman

    2003-04-01

    This report describes the Phase I effort to develop an Automated In Well Monitoring System (AIMS) for in situ detection of chlorinated volatile organic compounds such as trichloroethylene (TCE) and tetrachloroethylene (PCE) in groundwater. AIMS is composed of 3 primary components: (a) sensor probe, (b) instrument delivery system, and (c) communication/recharging station. The sensor probe utilizes an array of thickness shear mode (TSM) sensors coated with chemically-sensitive polymer films provides a low-cost, highly sensitive microsensor platform for detection and quantification. The instrument delivery system is used to position the sensor probe in 2 inch or larger groundwater monitoring wells. A communication/recharging station provides wireless battery recharging and communication to enable a fully automated system. A calibration curve for TCE in water was built using data collected in the laboratory. The detection limit of the sensor probe was 6.7 ppb ({micro}g/L) for TCE in water. A preliminary field test was conducted at a GE remediation location and a pilot field test was performed at the DOE Savannah River Site (SRS). The AIMS system was demonstrated in an uncontaminated (i.e., ''clean'') 2-inch well and in a 4-inch well containing 163.5 ppb of TCE. Repeat measurements at the two wells indicated excellent day-to-day reproducibility. Significant differences in the sensor responses were noted between the two types of wells but they did not closely match the laboratory calibration data. The robustness of the system presented numerous challenges for field work and limited the scope of the SRS pilot field test. However, the unique combination of trace detection (detection limits near the MCL, minimum concentration level) and size (operations in 2-inch or larger groundwater wells) is demonstration of the promise of this technology for long-term monitoring (LTM) applications or rapid site characterization. Using the lessons learned from the

  11. Incremental yield of bronchial washing for diagnosing smear-negative pulmonary tuberculosis

    Directory of Open Access Journals (Sweden)

    Alonso Soto

    2013-08-01

    Full Text Available OBJECTIVE To assess the increased diagnostic yield for pulmonary tuberculosis using bronchial washing cultures compared with sputum cultures. METHODS Study conducted with 61 adults in Lima, Peru, from January 2006 to December 2007. The yield of sputum cultures was compared with the yield of acid-fast bacilli smears and cultures of bronchial washing for diagnosing pulmonary tuberculosis in suspected cases of clinical tuberculosis with negative acid fast bacilli sputum smears. RESULTS Twenty seven (95%CI 32;58 of the cases were eventually diagnosed with smear-negative pulmonary tuberculosis. Bronchial washing samples detected 23 (95%CI 72;99 of the smear-negative pulmonary tuberculosis cases compared with 15 (95%CI 37;74 for sputum cultures (p = 0.02. The incremental diagnostic yield of acid fast bacilli smear and culture of bronchial washing specimens over sputum culture was 44% (95%CI 25;65. CONCLUSIONS In function of the epidemiological context and the resources available, bronchoscopy should be deployed as part of a comprehensive work up that optimizes smear-negative pulmonary tuberculosis diagnosis and minimizes risk and costs.

  12. Copper Recovery from Polluted Soils Using Acidic Washing and Bioelectrochemical Systems

    Directory of Open Access Journals (Sweden)

    Karin Karlfeldt Fedje

    2015-07-01

    Full Text Available Excavation followed by landfilling is the most common method for treating soils contaminated by metals. However, as this solution is not sustainable, alternative techniques are required. Chemical soil washing is one such alternative. The aim of this experimental lab-scale study is to develop a remediation and metal recovery method for Cu contaminated sites. The method is based on the washing of soil or ash (combusted soil/bark with acidic waste liquids followed by electrolytic Cu recovery by means of bioelectrochemical systems (BES. The results demonstrate that a one- or two-step acidic leaching process followed by water washing removes >80 wt. % of the Cu. Copper with 99.7–99.9 wt. % purity was recovered from the acidic leachates using BES. In all experiments, electrical power was generated during the reduction of Cu. This clearly indicates that Cu can also be recovered from dilute solutions. Additionally, the method has the potential to wash co-pollutants such as polycyclic aromatic hydrocarbons (PAHs and oxy-PAHs.

  13. Roles of EDTA washing and Ca{sup 2+} regulation on the restoration of anammox granules inhibited by copper(II)

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Zheng-Zhe; Cheng, Ya-Fei; Zhou, Yu-Huang; Buayi, Xiemuguli [Department of Environmental Science and Engineering, Hangzhou Normal University, Hangzhou 310036 (China); Key Laboratory of Hangzhou City for Ecosystem Protection and Restoration, Hangzhou Normal University, Hangzhou 310036 (China); Jin, Ren-Cun, E-mail: jrczju@aliyun.com [Department of Environmental Science and Engineering, Hangzhou Normal University, Hangzhou 310036 (China); Key Laboratory of Hangzhou City for Ecosystem Protection and Restoration, Hangzhou Normal University, Hangzhou 310036 (China)

    2016-01-15

    Highlights: • 80.5% of the Cu in anammox granules was introduced via adsorption. • Cu(II) internalized on/into AnAOB cells plays a crucial role in toxicity. • EDTA washing contributes to the detoxification of anammox granules. • Ca{sup 2+} can stimulate the re-growth of damaged anammox consortium. - Abstract: We investigated the feasibility of using ethylene diamine tetraacetic acid (EDTA) washing followed by Ca{sup 2+} enhancement for the recovery of anammox reactors inhibited by Cu(II). Kinetic experiments and batch activity assays were employed to determine the optimal concentration of EDTA and washing time; and the performance and physiological dynamics were tracked by continuous-flow monitoring to evaluate the long-term effects. The two-step desorption process revealed that the Cu in anammox granules was primarily introduced via adsorption (approximately, 80.5%), and the portion of Cu in the dispersible layer was predominant (accounting for 71.1%). Afterwards, the Cu internalized in the cells (approximately, 14.7%) could diffuse out of the cells and be gradually washed out of the reactor over the next 20 days. The Ca{sup 2+} addition that followed led to an accelerated nitrogen removal rate recovery slope (0.1491 kgN m{sup −3} d{sup −2}) and a normal biomass growth rate (0.054 d{sup −1}). The nitrogen removal rate returned to normal levels within 90 days and gradual improvements in granular characteristics were also achieved. Therefore, this study provides a new insight that externally removing the adsorbed heavy metals followed by internally repairing the metabolic system may represent an optimal restoration strategy for anammox consortium damaged by heavy metals.

  14. Suppression of deicing salt corrosion of weathering steel bridges by washing

    International Nuclear Information System (INIS)

    Hara, Shuichi; Miura, Masazumi; Uchiumi, Yasushi; Fujiwara, Toshiaki; Yamamoto, Masataka

    2005-01-01

    To elucidate the influences of deicing salts and high pressure (2-4 MPa) washing on the characteristics of the rust formed on weathering steel bridges, washing experiments have been carried out for three years. The rust was characterized by means of ion chromatography, X-ray diffraction and adsorption of N 2 . The rust thickness was measured, and also the rust weight per unit area of the steel surface was measured. It was found that water-soluble chloride accelerated the rate of corrosion because the rust particles grow by the chloride ions and micro-pore structure of the rust appeared by the chloride ions. Washing with water suppressed corrosion owing to the disappearance of chloride ions

  15. Monitoring of water quality of selected wells in Brno district

    Directory of Open Access Journals (Sweden)

    Marková Jana

    2016-06-01

    Full Text Available The article deals with two wells in the country of Brno-district (Brčálka well and Well Olšová. The aim of work was monitoring of elementary parameters of water at regular monthly intervals to measure: water temperature, pH values, solubility oxygen and spring yield. According to the client's requirements (Lesy města Brno laboratory analyzes of selected parameters were done twice a year and their results were compared with Ministry of Health Decree no. 252/2004 Coll.. These parameters: nitrate, chemical oxygen demand (COD, calcium and magnesium and its values are presented in graphs, for ammonium ions and nitrite in the table. Graphical interpretation of spring yields dependence on the monthly total rainfall and dependence of water temperature on ambient temperature was utilized. The most important features of wells include a water source, a landmark in the landscape, aesthetic element or resting and relaxing place. Maintaining wells is important in terms of future generations.

  16. Effect of washing and boiling on residues of pirimiphos-methyl in soybeans

    International Nuclear Information System (INIS)

    Sulistiawaty, M.; Anwar, E.

    1996-01-01

    The residues of pirimiphos-methyl (0-2-diethylamino-6-methyl-pyrimidine-4-il-o-dimethyl phos-phorothioate) in soybean grains were studied using 14 C-labelled-pirimiphos-methyl. Jute sock containing soybean grains were sprayed with pirimiphos-methyl and then stored at room temperature. The results indicated than residues of pirimiphos-methyl in soybeans before washing, after washing, and after washing + boiling at 0 week storage were: 1.0, 0.42, and 0.01%: then increased to 42.01, 30.75, and 10.02%, respectively, after 12 weeks, and finally decreased to 38.33, 27.01, and 6.10%, respectively, after 24 weeks storage. The residues of pirimiphos-methyl in washing water at 0 week storage was 0.41%, then increased to 8.01% after 24 weeks storage. The percentage was calculated based on the amount of residue found compared to the initial pirimiphos-methyl used. (author)

  17. High water level installation of monitoring wells for underground storage tanks

    International Nuclear Information System (INIS)

    Treadway, C.

    1990-01-01

    This paper briefly describes a common monitoring well installation design for shallow ground water contamination resulting from leaky underground storage tanks. The paper describes drilling techniques used in unconsolidated Florida aquifers using hollow-stem augers. It describes methods for the prevention of heaving sands and sand-locking problems. It then goes on to describe the proper well casing placement and sealing techniques using neat cements. The proper sell screen level is also discussed to maximize the detection of floating hydrocarbons

  18. Washing away your (good or bad) luck: physical cleansing affects risk-taking behavior.

    Science.gov (United States)

    Xu, Alison Jing; Zwick, Rami; Schwarz, Norbert

    2012-02-01

    Many superstitious practices entail the belief that good or bad luck can be "washed away." Consistent with this belief, participants who recalled (Experiment 1) or experienced (Experiment 2) an episode of bad luck were more willing to take risk after having as opposed to not having washed their hands, whereas participants who recalled or experienced an episode of good luck were less willing to take risk after having as opposed to not having washed their hands. Thus, the psychological effects of physical cleansings extend beyond the domain of moral judgment and are independent of people's motivation: incidental washing not only removes undesirable traces of the past (such as bad luck) but also desirable ones (such as good luck), which people would rather preserve.

  19. Effect of Disinfectants on Preventing the Cross-Contamination of Pathogens in Fresh Produce Washing Water

    NARCIS (Netherlands)

    Banach, J.L.; Sampers, I.; Haute, van S.; Fels, van der H.J.

    2015-01-01

    The potential cross-contamination of pathogens between clean and contaminated produce in the washing tank is highly dependent on the water quality. Process wash water disinfectants are applied to maintain the water quality during processing. The review examines the efficacy of process wash water

  20. Monitoring well design and sampling techniques at NAPL sites

    International Nuclear Information System (INIS)

    Collins, M.; Rohrman, W.R.; Drake, K.D.

    1992-01-01

    The existence of Non-Aqueous Phase Liquids (NAPLs) at many Superfund and RCRA hazardous waste sites has become a recognized problem in recent years. The large number of sites exhibiting this problem results from the fact that many of the most frequently used industrial solvents and petroleum products can exist as NAPLs. Hazardous waste constituents occurring as NAPLs possess a common characteristic that causes great concern during groundwater contamination evaluation: while solubility in water is generally very low, it is sufficient to cause groundwater to exceed Maximum Contamination Levels (MCLs). Thus, even a small quantity of NAPL within a groundwater regime can act as a point source with the ability to contaminate vast quantities of groundwater over time. This property makes it imperative that groundwater investigations focus heavily on characterizing the nature, extent, and migration pathways of NAPLs at sites where it exists. Two types of NAPLs may exist in a groundwater system. Water-immiscible liquid constituents having a specific gravity greater than one are termed Dense Non-Aqueous Phase Liquids, while those with a specific gravity less than one are considered Light Non-Aqueous Phase Liquids. For a groundwater investigation to properly characterize the two types of NAPLs, careful consideration must be given to the placement and sampling of groundwater monitoring wells. Unfortunately, technical reviewers at EPA Region VII and the Corps of Engineers find that many groundwater investigations fall short in characterizing NAPLs because several basic considerations were overlooked. Included among these are monitoring well location and screen placement with respect to the water table and significant confining units, and the ability of the well sampling method to obtain samples of NAPL. Depending on the specific gravity of the NAPL that occurs at a site, various considerations can substantially enhance adequate characterization of NAPL contaminants

  1. Study of electroflotation method for treatment of wastewater from washing soil contaminated by heavy metals

    Directory of Open Access Journals (Sweden)

    Izabel de Oliveira da Mota

    2015-04-01

    Full Text Available Electroflotation method (EFM for treatment of synthetic solutions simulating wastewater from washing soil contaminated by drilling fluids from oil wells was investigated in this paper. Experiments were carried out to examine the effects of the operating conditions on the removal of lead, barium and zinc from solutions containing 15 mg dm−3 for each metal representing a typical concentration of wastewater generated in the washing soil in this treatment. The experimental results showed that it is possible to remove these heavy metals by electrocoagulation/electroflotation (ECF attaining 97% of removal using stainless steel mesh electrodes with a power consumption of 14 kWh m−3. The optimal conditions of treatment were sodium dodecyl sulfate (SDS in a molar ratio 3:1, current density around 350 A m−2, ionic strength 3.2 × 10−3 M, pH = 10.0 and 20 min of ECF. This study newly indicated that the proposed method is adequate to simultaneously treat the common heavy metals found in the drilling fluids oil wells.

  2. The utility of fractional wash-out slope values following intravenous 133Xe

    International Nuclear Information System (INIS)

    Durak, H.; Bekdik, C.F.; Ulutuncel, N.

    1991-01-01

    The regional clearance of 133 Xe from the lungs after intravenous administration as well as following rebreathing was assessed in 7 normals and 18 patients with various lung disorders. Each lung was divided into three zones as upper, middle and lower. Regional ventilation (V) and regional perfusion (P) were determined using the area under the first peak at the beginning of the ventilation study and the area under the peak after intravenous administration, respectively. Slopes were calculated using the first exponential of the wash-out curve. Absolute slope values of the wash-out curves after perfusion (Pwo) and ventilation (Vwo) were expressed as a percentage of the total for each lung. Correlation coefficients between V and Vwo, V and Pwo, P and Pwo were .695, .584 and .882 in normals and .610, .461 and .685 in patients, respectively. It is concluded that Pwo is influenced by both perfusion and ventilation; it may reflect the fractional contribution to the gas exchange and can be used in the prediction of residual lung function after lung resection. (orig.) [de

  3. Soil physical characteristics after EDTA washing and amendment with inorganic and organic additives

    International Nuclear Information System (INIS)

    Zupanc, Vesna; Kastelec, Damijana; Lestan, Domen; Grcman, Helena

    2014-01-01

    Soil washing has been established as suitable remediation technology, with most research focused on metal removing efficiency and toxic effect on plants, less on the influence on soil physical characteristics, which was the focus of this study. In soil column experiment highly contaminated soil and soil washed with EDTA, mixed with additives (gypsum, hydrogel, manure, peat) were tested. White clover was used as a soil cover. Yield, metal concentration in soil and plant, aggregate fractionation and stability, saturated hydraulic conductivity and soil water retention of the soil were measured. Soil washing decreased metal concentration in soil and plants, but yield of white clover on remediated soil was significantly lower compared to the original soil. Significant differences in water retention characteristics, aggregate fractionation and stability between original and remediated soil have been determined. Gypsum, hydrogel and peat increased plant available water, manure and peat increased yield on remediated soil. -- Highlights: • Clover yield on washed soil was significantly lower than on original soil. • Organic additives increased yield on remediated soils. • Soil washing changed soil water retention and soil structure. • Hydrogen, gypsum and peat increased plant available water of remediated soil. -- The study critically examines yield, plant metal uptake and possible changes in soil physical characteristics as a consequence of soil washing procedure for metal pollution remediation

  4. Aquifer test at well SMW-1 near Moenkopi, Arizona

    Science.gov (United States)

    Carruth, Rob; Bills, Donald J.

    2012-01-01

    The Hopi villages of Lower Moencopi and Upper Moenkopi are on the Hopi Indian Reservation south of Tuba City in northern Arizona. These adjacent Hopi villages, located west and north of the confluence of Pasture Canyon Wash and Moenkopi Wash, are dependent on groundwater withdrawals from three wells that penetrate the N aquifer and from two springs that discharge from the N aquifer. The N aquifer is the principal aquifer in this region of northern Arizona and is composed of thick beds of sandstone between less permeable layers of siltstone and mudstone. The fine-grained character of the N aquifer inhibits rapid movement of water and large yields to wells; however, the aquifer is moderately productive at yields generally less than 25 gallons per minute in the study area. In recent years, the water level has declined in the three public-supply wells and the flow from the springs has decreased, causing concern that the current water supply will not be able to accommodate peak demand and allow for residential and economic growth. In addition to the challenge imposed by declining groundwater levels, the water-supply wells and springs are located about 2 miles downgradient from the Tuba City Landfill site where studies are ongoing to determine if uranium and other metals in groundwater beneath the landfill are higher than regional concentrations in the N aquifer. In August 2008, the U.S. Geological Survey, in cooperation with the Hopi Tribe, conducted an aquifer test on well SMW-1, designed to help the Hopi Tribe determine the potential yield and water quality of the N aquifer south of Moenkopi Wash as a possible source of additional water supply. Well SMW-1 was drilled south of Moenkopi Wash to a depth of 760 feet below land surface before being backfilled and cased to about 300 feet. The well penetrates, in descending order, the Navajo Sandstone and the Kayenta Formation, both units of the N aquifer. The pre-test water level in the well was 99.15 feet below land

  5. Hand Washing Practices Among Emergency Medical Services Providers

    Directory of Open Access Journals (Sweden)

    Joshua Bucher

    2015-10-01

    Full Text Available Introduction: Hand hygiene is an important component of infection control efforts. Our primary and secondary goals were to determine the reported rates of hand washing and stethoscope cleaning in emergency medical services (EMS workers, respectively. Methods: We designed a survey about hand hygiene practices. The survey was distributed to various national EMS organizations through e-mail. Descriptive statistics were calculated for survey items (responses on a Likert scale and subpopulations of survey respondents to identify relationships between variables. We used analysis of variance to test differences in means between the subgroups. Results: There were 1,494 responses. Overall, reported hand hygiene practices were poor among pre-hospital providers in all clinical situations. Women reported that they washed their hands more frequently than men overall, although the differences were unlikely to be clinically significant. Hygiene after invasive procedures was reported to be poor. The presence of available hand sanitizer in the ambulance did not improve reported hygiene rates but improved reported rates of cleaning the stethoscope (absolute difference 0.4, p=0.0003. Providers who brought their own sanitizer were more likely to clean their hands. Conclusion: Reported hand hygiene is poor amongst pre-hospital providers. There is a need for future intervention to improve reported performance in pre-hospital provider hand washing.

  6. Hand Washing Practices Among Emergency Medical Services Providers.

    Science.gov (United States)

    Bucher, Joshua; Donovan, Colleen; Ohman-Strickland, Pamela; McCoy, Jonathan

    2015-09-01

    Hand hygiene is an important component of infection control efforts. Our primary and secondary goals were to determine the reported rates of hand washing and stethoscope cleaning in emergency medical services (EMS) workers, respectively. We designed a survey about hand hygiene practices. The survey was distributed to various national EMS organizations through e-mail. Descriptive statistics were calculated for survey items (responses on a Likert scale) and subpopulations of survey respondents to identify relationships between variables. We used analysis of variance to test differences in means between the subgroups. There were 1,494 responses. Overall, reported hand hygiene practices were poor among pre-hospital providers in all clinical situations. Women reported that they washed their hands more frequently than men overall, although the differences were unlikely to be clinically significant. Hygiene after invasive procedures was reported to be poor. The presence of available hand sanitizer in the ambulance did not improve reported hygiene rates but improved reported rates of cleaning the stethoscope (absolute difference 0.4, p=0.0003). Providers who brought their own sanitizer were more likely to clean their hands. Reported hand hygiene is poor amongst pre-hospital providers. There is a need for future intervention to improve reported performance in pre-hospital provider hand washing.

  7. Effect and Removal Mechanisms of 6 Different Washing Agents for Building Wastes Containing Chromium

    Directory of Open Access Journals (Sweden)

    Wang Xing-run

    2012-01-01

    Full Text Available With the building wastes contaminated by chromium in Haibei Chemical Plan in China as objects, we studied the contents of total Cr and Cr (VI of different sizes, analyzed the effect of 6 different washing agents, discussed the removal mechanisms of 6 different washing agents for Cr in various forms, and finally selected applicable washing agent. As per the results, particle size had little impact on the contents of total Cr and Cr (VI; after one washing with water, the removal rate of total Cr and Cr (VI was 75% and 78%, respectively, and after the second washing with 6 agents, the removal rate of citric acid was the highest, above 90% for total Cr and above 99% for hexavalent chromium; the pH of building wastes were reduced by citric acid, and under acid condition, hexavalent chromium was reduced to trivalent chromium spontaneously by organic acid, which led to better removal rate of acid soluble Cr and reducible Cr; due to the complexing action, citric acid had best removal rate for oxidizable trivalent chromium. In conclusion, citric acid is the most applicable second washing agent for building wastes.

  8. Evaluation of Pre- and Post- Redevelopment Groundwater Chemical Analyses from LM Monitoring Wells

    International Nuclear Information System (INIS)

    Kamp, Susan; Dayvault, Jalena

    2016-01-01

    This report documents the efforts and analyses conducted for the Applied Studies and Technology (AS&T) Ancillary Work Plan (AWP) project titled Evaluation of Pre- and Post- Redevelopment Groundwater Sample Laboratory Analyses from Selected LM Groundwater Monitoring Wells. This effort entailed compiling an inventory of nearly 500 previous well redevelopment events at 16 U.S. Department of Energy Office of Legacy Management (LM) sites, searching the literature for impacts of well redevelopment on groundwater sample quality, and-the focus of this report-evaluating the impacts of well redevelopment on field measurements and sample analytical results. Study Catalyst Monitoring well redevelopment, the surging or high-volume pumping of a well to loosen and remove accumulated sediment and biological build-up from a well, is considered an element of monitoring well maintenance that is implemented periodically during the lifetime of the well to mitigate its gradual deterioration. Well redevelopment has been conducted fairly routinely at a few LM sites in the western United States (e.g., the Grand Junction office site and the Gunnison processing site in Colorado), but at most other sites in this region it is not a routine practice. Also, until recently (2014-2015), there had been no specific criteria for implementing well redevelopment, and documentation of redevelopment events has been inconsistent. A catalyst for this evaluation was the self-identification of these inconsistencies by the Legacy Management Support contractor. As a result, in early 2015 Environmental Monitoring Operations (EMO) staff began collecting and documenting additional field measurements during well redevelopment events. In late 2015, AS&T staff undertook an independent internal evaluation of EMO's well redevelopment records and corresponding pre- and post-well-redevelopment groundwater analytical results. Study Findings Although literature discussions parallel the prevailing industry

  9. Evaluation of Pre- and Post- Redevelopment Groundwater Chemical Analyses from LM Monitoring Wells

    Energy Technology Data Exchange (ETDEWEB)

    Kamp, Susan [Navarro Reserch and Engineering, Oak Ridge, TN (United States); Dayvault, Jalena [US Department of Energy, Washington, DC (United States). Office of Legacy Management

    2016-05-01

    This report documents the efforts and analyses conducted for the Applied Studies and Technology (AS&T) Ancillary Work Plan (AWP) project titled Evaluation of Pre- and Post- Redevelopment Groundwater Sample Laboratory Analyses from Selected LM Groundwater Monitoring Wells. This effort entailed compiling an inventory of nearly 500 previous well redevelopment events at 16 U.S. Department of Energy Office of Legacy Management (LM) sites, searching the literature for impacts of well redevelopment on groundwater sample quality, and—the focus of this report—evaluating the impacts of well redevelopment on field measurements and sample analytical results. Study Catalyst Monitoring well redevelopment, the surging or high-volume pumping of a well to loosen and remove accumulated sediment and biological build-up from a well, is considered an element of monitoring well maintenance that is implemented periodically during the lifetime of the well to mitigate its gradual deterioration. Well redevelopment has been conducted fairly routinely at a few LM sites in the western United States (e.g., the Grand Junction office site and the Gunnison processing site in Colorado), but at most other sites in this region it is not a routine practice. Also, until recently (2014–2015), there had been no specific criteria for implementing well redevelopment, and documentation of redevelopment events has been inconsistent. A catalyst for this evaluation was the self-identification of these inconsistencies by the Legacy Management Support contractor. As a result, in early 2015 Environmental Monitoring Operations (EMO) staff began collecting and documenting additional field measurements during well redevelopment events. In late 2015, AS&T staff undertook an independent internal evaluation of EMO's well redevelopment records and corresponding pre- and post-well-redevelopment groundwater analytical results. Study Findings Although literature discussions parallel the prevailing industry

  10. 141Ce as a tracer to find the efficient washing method for hair in the analysis of rare earth elements

    International Nuclear Information System (INIS)

    Tong Shilu

    1989-01-01

    Various procedures were compared in relation to the removal of 141 Ce exogenously contaminated as well as endogenously incorporated in hair. Extraction efficiency of cerium with hot EDTA was the greatest among the four washing procedures. However, no procedure can effectively remove all exogenous cerium without reducing the endogenous cerium. Among the four procedures evaluated, washing with 0.1 mol/l EDTA (50 deg C, 10 minutes) is recommended before the analysis of rare earth elements in hair because of its efficiency in removing exogenous cerium and causing less loss on endogenous cerium

  11. Computer simulation of laboratory leaching and washing of tank waste sludges

    International Nuclear Information System (INIS)

    Meng, C.D.; MacLean, G.T.; Landeene, B.C.

    1994-01-01

    The process simulator ESP (Environmental Simulation Program) was used to simulate laboratory caustic leaching and washing of core samples from Tanks B-110, C-109, and C-112. The results of the laboratory tests and the computer simulations are compared. The results from both, agreed reasonably well for elements contained in solid phases included in the ESP Public data bank. The use of the GEOCHEM data bank and/or a custom Hanford Data bank should improve the agreement, making ESP a useful process simulator for aqueous based processing

  12. Axial Dispersion during Hanford Saltcake Washing

    International Nuclear Information System (INIS)

    Josephson, Gary B.; Geeting, John GH; Lessor, Delbert L.; Barton, William B.

    2006-01-01

    Clean up of Hanford salt cake wastes begins with dissolution retrieval of the sodium rich salts that make up the dominant majority of mass in the tanks. Water moving through the porous salt cake dissolves the soluble components and also displaces the soluble radionuclides (e.g. 137Cs and 99TcO4- ). The separation that occurs from this displacement, known as Selective dissolution, is an important component in Hanford?s pretreatment of low activity wastes for subsequent Supplemental treatment. This paper describes lab scale testing conducted to evaluate Selective dissolution of cesium from non-radioactive Hanford tank 241-S-112 salt cake simulant containing the primary chemicals found the actual tank. An modified axial dispersion model with increasing axial dispersion was developed to predict cesium removal. The model recognizes that water dissolves the salt cake during washing, which causes an increase in the axial dispersion during the wash. This model was subsequently compared with on-line cesium measurements from the retrieval of tank 241-S-112. The model had remarkably good agreement with both the lab scale and full scale data

  13. Monitoring of Carrying Cable in the Well by Electric Drive of Winch at the Logging Works

    International Nuclear Information System (INIS)

    Odnokopylov, I G; Gneushev, V V; Larioshina, I A

    2016-01-01

    Emergency situations during logging operations are considered. The necessity of monitoring of the carrying cable in the well was shown, especially at the jet perforation and seismic researches of wells. The way of monitoring of logging cable and geophysical probe by means of the electric drive of tripping works of the logging winch is offered. This method allows timely to identify the wedges of geophysical equipment and the tension of the cable in well without interfering into construction of logging installation by means of algorithmic processing of sensors of electric drive. Research was conducted on the simulation model; these results indirectly confirm the possibility of using of electric drive for monitoring of downhole equipment. (paper)

  14. Monitoring of Carrying Cable in the Well by Electric Drive of Winch at the Logging Works

    Science.gov (United States)

    Odnokopylov, I. G.; Gneushev, V. V.; Larioshina, I. A.

    2016-01-01

    Emergency situations during logging operations are considered. The necessity of monitoring of the carrying cable in the well was shown, especially at the jet perforation and seismic researches of wells. The way of monitoring of logging cable and geophysical probe by means of the electric drive of tripping works of the logging winch is offered. This method allows timely to identify the wedges of geophysical equipment and the tension of the cable in well without interfering into construction of logging installation by means of algorithmic processing of sensors of electric drive. Research was conducted on the simulation model; these results indirectly confirm the possibility of using of electric drive for monitoring of downhole equipment.

  15. Work plan for ground water elevation data recorder/monitor well installation at Gunnison, Colorado

    International Nuclear Information System (INIS)

    1994-01-01

    The purpose of this document is to describe the work that will be performed and the procedures that will be followed during installation of ground water monitor wells and ground water elevation data recorders (data loggers) at the Gunnison, Colorado, Uranium Mill Tailings Remedial Action (UMTRA) Project site. The monitor wells and data loggers will be used to gather required time-dependent data to investigate the interaction between ground water and surface water in the area. Data collection objectives (DCO) identify reasons for collecting data. The following are DCOs for the Gunnison ground water elevation data recorder/monitor well installation project: long-term continuous ground water level data and periodic ground water samples will be collected to better understand the relationship between surface and ground water at the site; water level and water quality data will eventually be used in future ground water modeling to more firmly establish boundary conditions in the vicinity of the Gunnison processing site; and modeling results will be used to demonstrate and document the potential remedial alternative of natural flushing

  16. Volume reduction system by soil classifying. Soil-washing system and problems to be solved

    International Nuclear Information System (INIS)

    Oshino, Yoshio

    2016-01-01

    Radioactive contamination of ground surfaces, buildings and forests in a broad area was caused by the accident at the Fukushima Daiichi Nuclear Power Plant in Japan. The national government and municipalities have still been carrying out the decontamination works for livelihood areas after five years from the accident. The government estimated that the amounts of soils and wastes removed by the decontamination works would be about 28,000,000 cubic meters maximum including 20,000,000 cubic meters maximum of soils. The removed soils will be stored in “Interim Storage Facility” then will be finally disposed outside of Fukushima prefecture within 30 years. On the other hand, shortage of the soils as materials needed for the revitalization in Fukushima prefecture is expected. Technical Advisory Council on Remediation and Waste Management, which consists of about 90 companies, started a working group to investigate solutions to these problems. The working group focused on the investigation of the possibility to recycle the soils by washing and classification to use them as the materials for civil engineering works, and to reduce the volume of the interim storage. In the first part of this report, we have evaluated the applicability of various technologies for purification and volume reduction of the removed soils, and have researched usages, required quantities and specifications of the recycled soils. In the second part, we have made trial calculations of the volume reduction effects and costs using the washing and classification system. The calculated results showed the possibilities of reducing the storage capacity of the interim storage facility, as well as the construction and the operation costs by recycling the removed soils with the washing and classification system inside the interim storage facility. At the end of this report, we proposed problems to be solved in order to adopt the washing and classification system. (author)

  17. Qualification testing and full-scale demonstration of titanium-treated zeolite for sludge wash processing

    Energy Technology Data Exchange (ETDEWEB)

    Dalton, W.J.

    1997-06-30

    Titanium-treated zeolite is a new ion-exchange material that is a variation of UOP (formerly Union Carbide) IONSIV IE-96 zeolite (IE-96) that has been treated with an aqueous titanium solution in a proprietary process. IE-96 zeolite, without the titanium treatment, has been used since 1988 in the West Valley Demonstration Project`s (WVDP) Supernatant Treatment System (STS) ion-exchange columns to remove Cs-137 from the liquid supernatant solution. The titanium-treated zeolite (TIE-96) was developed by Battelle-Pacific Northwest Laboratory (PNL). Following successful lab-scale testing of the PNL-prepared TIE-96, UOP was selected as a commercial supplier of the TIE-96 zeolite. Extensive laboratory tests conducted by both the WVDP and PNL indicate that the TIE-96 will successfully remove comparable quantities of Cs-137 from Tank 8D-2 high-level radioactive liquid as was done previously with IE-96. In addition to removing Cs-137, TIE-96 also removes trace quantities of Pu, as well as Sr-90, from the liquid being processed over a wide range of operating conditions: temperature, pH, and dilution. The exact mechanism responsible for the Pu removal is not fully understood. However, the Pu that is removed by the TIE-96 remains on the ion-exchange column under anticipated sludge wash processing conditions. From May 1988 to November 1990, the WVDP processed 560,000 gallons of liquid high-level radioactive supernatant waste stored in Tank 8D-2. Supernatant is an aqueous salt solution comprised primarily of soluble sodium salts. The second stage of the high-level waste treatment process began November 1991 with the initiation of sludge washing. Sludge washing involves the mixing of Tank 8D-2 contents, both sludge and liquid, to dissolve the sulfate salts present in the sludge. Two sludge washes were required to remove sulfates from the sludge.

  18. Superstorm Sandy marine debris wash-ups on Long Island - What happened to them?

    Science.gov (United States)

    Swanson, R Lawrence; Lwiza, Kamazima; Willig, Kaitlin; Morris, Kaitlin

    2016-07-15

    Superstorm Sandy generated huge quantities of debris in the Long Island, NY coastal zone. However, little appears to have been washed offshore to eventually be returned to Long Island's beaches as marine debris wash-ups. Information for our analysis includes debris collection statistics, very high resolution satellite images, along with wind and sea level data. Rigorous debris collection efforts along with meteorological conditions following the storm appear to have reduced the likelihood of debris wash-ups. Copyright © 2016 Elsevier Ltd. All rights reserved.

  19. Design and Development of a Web-Based Self-Monitoring System to Support Wellness Coaching.

    Science.gov (United States)

    Zarei, Reza; Kuo, Alex

    2017-01-01

    We analyzed, designed and deployed a web-based, self-monitoring system to support wellness coaching. A wellness coach can plan for clients' exercise and diet through the system and is able to monitor the changes in body dimensions and body composition that the client reports. The system can also visualize the client's data in form of graphs for both the client and the coach. Both parties can also communicate through the messaging feature embedded in the application. A reminder system is also incorporated into the system and sends reminder messages to the clients when their reporting is due. The web-based self-monitoring application uses Oracle 11g XE as the backend database and Application Express 4.2 as user interface development tool. The system allowed users to access, update and modify data through web browser anytime, anywhere, and on any device.

  20. Investigation of heterogeneous ice nucleation in pollen suspensions and washing water

    Science.gov (United States)

    Dreischmeier, Katharina; Budke, Carsten; Koop, Thomas

    2014-05-01

    Biological particles such as pollen often show ice nucleation activity at temperatures higher than -20 °C. Immersion freezing experiments of pollen washing water demonstrate comparable ice nucleation behaviour as water containing the whole pollen bodies (Pummer et al., 2012). It was suggested that polysaccharide molecules leached from the grains are responsible for the ice nucleation. Here, heterogeneous ice nucleation in birch pollen suspensions and their washing water was investigated by two different experimental methods. The optical freezing array BINARY (Bielefeld Ice Nucleation ARraY) allows the direct observation of freezing of microliter-sized droplets. The IN spectra obtained from such experiments with birch pollen suspensions over a large concentration range indicate several different ice nucleation active species, two of which are present also in the washing water. The latter was probed also in differential scanning calorimeter (DSC) experiments of emulsified sub-picoliter droplets. Due to the small droplet size in the emulsion samples and at small concentration of IN in the washing water, such DSC experiments can exhibit the ice nucleation behaviour of a single nucleus. The two heterogeneous freezing signals observed in the DSC thermograms can be assigned to two different kinds of ice nuclei, confirming the observation from the BINARY measurements, and also previous studies on Swedish birch pollen washing water (Augustin et al., 2012). The authors gratefully acknowledge funding by the German Research Foundation (DFG) through the project BIOCLOUDS (KO 2944/1-1) and through the research unit INUIT (FOR 1525) under KO 2944/2-1. We particularly thank our INUIT partners for fruitful collaboration and sharing of ideas and IN samples. S. Augustin, H. Wex, D. Niedermeier, B. Pummer, H. Grothe, S. Hartmann, L. Tomsche, T. Clauss, J. Voigtländer, K. Ignatius, and F. Stratmann, Immersion freezing of birch pollen washing water, Atmos. Chem. Phys., 13, 10989

  1. Washing away your sins will set your mind free: physical cleansing modulates the effect of threatened morality on executive control.

    Science.gov (United States)

    Kalanthroff, Eyal; Aslan, Chen; Dar, Reuven

    2017-01-01

    The effect of threatened morality on negative emotions and on altruistic behaviour has been shown to diminish following physical cleansing (hand-washing). We hypothesised that threatened morality will broadly impair the executive control system, and that physical cleansing will moderate this detrimental effect. Thirty-seven participants were asked to write about an immoral deed they had committed, whereupon half of them were allowed to wipe their hands. Three executive control tasks-Stroop, stop-signal, and object interference-were then administered to all participants. Participants who had not wiped their hands, but not those who did, demonstrated impaired performance, compared to hand-washing controls, in all three tasks. We conclude that threatened morality has a detrimental effect on executive control, specifically on conflict monitoring and response inhibition, and that physical cleansing "frees" this system, counteracting the detrimental effects of morality threats. We discuss possible implications for obsessive-compulsive disorder, which is characterised by deficient executive control and in which both threatened morality and physical cleansing are central concerns.

  2. Combined soil washing and CDEO for the removal of atrazine from soils

    Energy Technology Data Exchange (ETDEWEB)

    Vieira dos Santos, Elisama [Institute of Chemistry, Federal University of Rio Grande do Norte, Lagoa Nova CEP 59078-970, Natal, RN (Brazil); Sáez, Cristina [Department of Chemical Engineering, Universidad de Castilla – La Mancha, Enrique Costa Building, Campus Universitario s/n, 13071 Ciudad Real (Spain); Martínez-Huitle, Carlos Alberto [Institute of Chemistry, Federal University of Rio Grande do Norte, Lagoa Nova CEP 59078-970, Natal, RN (Brazil); Cañizares, Pablo; Rodrigo, Manuel Andres [Department of Chemical Engineering, Universidad de Castilla – La Mancha, Enrique Costa Building, Campus Universitario s/n, 13071 Ciudad Real (Spain)

    2015-12-30

    Highlights: • Sequential soil washing-waste electrolysis is an efficient treatment for removing atrazine. • Ratio surfactant/soil influences on the size of micelles and organic load. • Electrolysis with diamond anodes oxidizes pollutants from soils washing wastes. • Electrolysis of soil washing fluids promotes the reduction in size of micelles. • Sulphate ions release from the oxidation of SDS participates in the oxidation process. - Abstract: In this work, it is studied the removal of atrazine from spiked soils by soil washing using surfactant fluids, followed by the treatment of the resulting washing waste by electrolysis with boron doped diamond (BDD) anode. Results confirm that combination of both technologies is efficient for the removal and total mineralization of atrazine. Ratio surfactant/soil is a key parameter for the removal of atrazine from soil and influences significantly in the characteristic of the wastewater produced, affecting not only to the total organic load but also to the mean size of micelles. The higher the ratio surfactant soil, the lower is the size of the particles. Electrolyses of this type of waste attain the complete mineralization. TOC and COD are removed from the start of the treatment but the key of the treatment is the reduction in size of the micelles, which lead to a higher negative charge in the surface and to the faster depletion of the surfactant as compared with the pesticide.

  3. A soil washing pilot plant for removing petroleum hydrocarbons from contaminated soils

    International Nuclear Information System (INIS)

    Toor, I.A.; Roehrig, G.R.

    1992-01-01

    A soil washing pilot plant was built and tested for its ability to remove petroleum hydrocarbons from certain soils. The ITEX soil washing pilot plant is a trailer mountable mobile unit which has a washing capacity of two tons per hour of contaminated soils. A benchscale study was carried out prior to the fabrication of the pilot plant. The first sample was contaminated with diesel fuel while the second sample was contaminated with crude oil. Various nonionic, cationic and anionic cleaning agents were evaluated for their ability to remove petroleum hydrocarbons from these materials. The nonionic cleaning agents were more successful in cleaning the soils in general. The ultimate surfactant choice was based on several factors including cost, biodegradability, cleaning efficiency and other technical considerations. The soil samples were characterized in terms of their particle size distributions. Commercial diesel fuel was carefully mixed in this sand to prepare a representative sample for the pilot plant study. Two pilot runs were made using this material. A multistage washing study was also conducted in the laboratory which indicates that the contamination level can be reduced to 100 ppm using only four stages. Because the pilot plant washing efficiency is twice as high, it is believed that ultimate contamination levels can be reduced to lower levels using the same number of stages. However, this hypothesis has not been demonstrated to date

  4. Performance Study of Screen-Printed Textile Antennas after Repeated Washing

    Directory of Open Access Journals (Sweden)

    Kazani I.

    2014-06-01

    Full Text Available The stability of wearable textile antennas after 20 reference washing cycles was evaluated by measuring the reflection coefficient of different antenna prototypes. The prototypes’ conductive parts were screen-printed on several textile substrates using two different silver-based conductive inks. The necessity of coating the antennas with a thermoplastic polyurethane (TPU coating was investigated by comparing coated with uncoated antennas. It is shown that covering the antennas with the TPU layer not only protects the screen-printed conductive area but also prevents delamination of the multilayered textile fabric substrates, making the antennas washable for up to 20 cycles. Furthermore, it is proven that coating is not necessary for maintaining antenna operation and this up to 20 washing cycles. However, connector detachment caused by friction during the washing process was the main problem of antenna performance degradation. Hence, other flexible, durable methods should be developed for establishing a stable electrical connection.

  5. Status and progress in sludge washing: A pivotal pretreatment method

    International Nuclear Information System (INIS)

    Barton, W.B.; MacLean, G.T.; Meng, C.D.; Winkler, C.M.

    1995-01-01

    Separation of the bulk soluble chemical salts from the insoluble metal hydroxides and radionuclides is central to the strategy of disposing Hanford tank waste. Sludge washing and caustic leaching have been selected as the primary methods for processing the 230 million L (61,000,000 gal) of Hanford tank waste. These processes are very similar to those selected for processing waste at the West Valley Site in New York and the Savannah River Site in South Carolina. The purpose of sludge washing is to dissolve and remove the soluble salts in the waste. Leaching of the insoluble solids with caustic will be used to dissolve aluminum hydroxide and chromium hydroxide, and convert insoluble bismuth phosphate to soluble phosphate. The waste will be separated into a high-level solids fraction and a liquid fraction that can be disposed of as low-level waste after cesium removal. The washing and leaching operations involve batchwise mixing, settling, and decanting within the existing underground storage tanks

  6. Why Is Hand Washing So Important? (For Parents)

    Science.gov (United States)

    ... hand washing a rule for everyone, especially: before eating and cooking after using the bathroom after cleaning around the house after touching animals, including family pets before and after visiting or ...

  7. Treatment techniques for the recycling of bottle washing water in the soft drinks industry.

    Science.gov (United States)

    Ramirez Camperos, E; Mijaylova Nacheva, P; Diaz Tapia, E

    2004-01-01

    The soft drink production is an important sector in the manufacturing industry of Mexico. Water is the main source in the production of soft drinks. Wastewater from bottle washing is almost 50% of the total wastewater generated by this industry. In order to reduce the consumption of water, the water of the last bottle rinse can be reused in to the bottle pre-rinse and pre-washing cycles. This work presents the characterization of the final bottle washing rinse discharge and the treatability study for the most appropriate treatment system for recycling. Average characteristics of the final bottle wash rinse were as follows: Turbidity 40.46 NTU, COD 47.7 mg/L, TSS 56 mg/L, TS 693.6 mg/L, electrical conductivity 1,194 microS/cm. The results of the treatability tests showed that the final rinse water can be used in the pre-rinse and pre-washing after removing the totality of the suspended solids, 80% of the COD and 75% of the dissolved solids. This can be done using the following treatment systems: filtration-adsorption-reverse osmosis, or filtration-adsorption-ion exchange. The installation of these treatment techniques in the soft drink industry would decrease bottle washing water consumption by 50%.

  8. Sound the alarm : monitoring system's real-time data reduces well downtime

    Energy Technology Data Exchange (ETDEWEB)

    Harrison, L.

    2008-10-15

    This article presented a new electrical heating element tool used to boost performance at low-producing wells. The down hole tool (DHT) was designed to generate steam underground in order to avoid the energy losses associated with above-ground equipment. The tool operates like an oven element but is connected to a computerized well-monitoring system in order to ensure that heat is evenly distributed. The DHT is equipped with an Optiview monitoring system designed to provide continuous readouts of near real time data. The system can also be customized to deliver messages to telephones, computers, or alarm systems. Changes in hydraulic torque, flow rates, tank levels, speeds, temperatures and hydraulic pressures can be set within ranges in order to optimize oil and gas well production by reducing operating costs and increasing equipment efficiencies. Use of the tool has during tests has minimized the need for well servicing. The patent pending technology is also being investigated for its use in water disposal and other pump-to-surface units. It was concluded that use of the technology will allow oil and gas managers to determine the status of wells in remote locations. 1 fig.

  9. Characterization, Washing, Leaching, and Filtration of C-104 Sludge

    Energy Technology Data Exchange (ETDEWEB)

    KP Brooks; PR Bredt; GR Golcar; SA Hartley; LK Jagoda; KG Rappe; MW Urie

    2000-06-09

    Approximately 1,400 g of wet Hanford Tank C-104 Sludge was evaluated by Battelle for the high-level waste (HLW) pretreatment processes of ultrafiltration, dilute caustic washing, and elevated-temperature caustic leaching. The filterability of diluted C-104 sludge was measured with a 0.1-{micro}m sintered metal Mott filter using a 24-inch-long, single-element, crossflow filtration system (cells unit filter [CUF]). While the filtrate was being recirculated prior to washing and leaching, a 6.9 wt% solids slurry was evaluated with a matrix of seven 1-hour conditions of varying trans-membrane pressure (30 to 70 psid) and axial velocity (9 to 15 ft/s). The filtrate flux and backpulse efficiency were determined for each condition. The slurry was concentrated to 23 wt% solids, a second matrix of six 1-hour conditions was performed, and data analogous to that recorded in the first matrix were obtained. The low-solids-concentration matrix produced filtrate flux rates that ranged from 0.038 to 0.083 gpm/ft{sup 2}. The high-solids-concentration matrix produced filtrate flux rates that ranged from 0.0095 to 0.0172 gpm/ft{sup 2}. In both cases, the optimum filtrate flux was at the highest axial velocity (15 ft/s) and transmembrane pressure had little effect. Nearly all of the measured filtrate fluxes were more than an order of magnitude greater than the required plant flux for C-104 of 0.00126 gpm/ft{sup 2}. In both matrices, the filtrate flux appeared to be proportional to axial velocity, and the permeability appeared to be inversely proportional to the trans-membrane pressure. The first test condition was repeated as the last test condition for each matrix. In both cases, there was a significant decrease in filtrate flux, indicating some filter fouling during the test matrix that could not be removed by backpulsing alone, although the backpulse number and duration were not optimized. Following testing of these two matrices, the material was washed within the CUF by

  10. Exploring the gap between hand washing knowledge and practices in Bangladesh: a cross-sectional comparative study.

    Science.gov (United States)

    Rabbi, Sifat E; Dey, Nepal C

    2013-01-30

    Hand washing is considered as one of the most effective hygiene promotion activities for public health in developing countries. This study compared hand washing knowledge and practices in BRAC's water; sanitation and hygiene (WASH) programme areas over time. This study is a cross-sectional comparative study between baseline (2006), midline (2009) and end-line (2011) surveys in 50 sub-districts from the first phase of the programme. Thirty thousand households from 50 sub-districts were selected in two steps: i) 30 villages were selected from each sub-district by cluster sampling, and ii) 20 households were chosen systematically from each village. The matched households were considered (26,404 in each survey) for analysis. Data were collected from households through face-to-face interview using a pre-tested questionnaire. Respondents were the adult female members of the same households, who had knowledge of day-to-day household activities related to water, sanitation and hygiene. A gap between perception and practice of proper hand washing practices with soap was identified in the study areas. Hand washing practice with soap before eating was much lower than after defecation. In baseline data, 8% reported to wash their hands with soap which significantly increased to 22% in end line. Hand washing knowledge and practices before cooking food, before serving food and while handling babies is considerably limited than other critical times. A multivariate analysis shows that socio-economic factors including education of household head and respondent, water availability and access to media have strong positive association with hand washing with soap. Gap between knowledge and practice still persists in hand washing practices. Long term and extensive initiatives can aware people about the effectiveness of hand washing.

  11. Exploring the gap between hand washing knowledge and practices in Bangladesh: a cross-sectional comparative study

    Directory of Open Access Journals (Sweden)

    Rabbi Sifat E

    2013-01-01

    Full Text Available Abstract Background Hand washing is considered as one of the most effective hygiene promotion activities for public health in developing countries. This study compared hand washing knowledge and practices in BRAC’s water; sanitation and hygiene (WASH programme areas over time. Methods This study is a cross-sectional comparative study between baseline (2006, midline (2009 and end-line (2011 surveys in 50 sub-districts from the first phase of the programme. Thirty thousand households from 50 sub-districts were selected in two steps: i 30 villages were selected from each sub-district by cluster sampling, and ii 20 households were chosen systematically from each village. The matched households were considered (26,404 in each survey for analysis. Data were collected from households through face-to-face interview using a pre-tested questionnaire. Respondents were the adult female members of the same households, who had knowledge of day-to-day household activities related to water, sanitation and hygiene. Results A gap between perception and practice of proper hand washing practices with soap was identified in the study areas. Hand washing practice with soap before eating was much lower than after defecation. In baseline data, 8% reported to wash their hands with soap which significantly increased to 22% in end line. Hand washing knowledge and practices before cooking food, before serving food and while handling babies is considerably limited than other critical times. A multivariate analysis shows that socio-economic factors including education of household head and respondent, water availability and access to media have strong positive association with hand washing with soap. Conclusion Gap between knowledge and practice still persists in hand washing practices. Long term and extensive initiatives can aware people about the effectiveness of hand washing.

  12. Waste washing pre-treatment of municipal and special waste.

    Science.gov (United States)

    Cossu, Raffaello; Lai, Tiziana; Pivnenko, Kostyantyn

    2012-03-15

    Long-term pollution potential in landfills is mainly related to the quality of leachate. Waste can be conveniently treated prior to landfilling with an aim to minimizing future emissions. Washing of waste represents a feasible pre-treatment method focused on controlling the leachable fraction of residues and relevant impact. In this study, non-recyclable plastics originating from source segregation, mechanical-biological treated municipal solid waste (MSW), bottom ash from MSW incineration and automotive shredder residues (ASR) were treated and the removal efficiency of washing pre-treatment prior to landfilling was evaluated. Column tests were performed to simulate the behaviour of waste in landfill under aerobic and anaerobic conditions. The findings obtained revealed how waste washing treatment (WWT) allowed the leachability of contaminants from waste to be reduced. Removal rates exceeding 65% were obtained for dissolved organic carbon (DOC), chemical oxygen demand (COD) and Total Kjeldahl Nitrogen (TKN). A percentage decrease of approximately 60% was reached for the leachable fraction of chlorides, sulphates, fluoride and metals, as proved by a reduction in electric conductivity values (70%). Copyright © 2011 Elsevier B.V. All rights reserved.

  13. Point-of-care washing of allogeneic red blood cells for the prevention of transfusion-related respiratory complications (WAR-PRC): a protocol for a multicenter randomised clinical trial in patients undergoing cardiac surgery

    Science.gov (United States)

    Warner, Matthew A; Welsby, Ian J; Norris, Phillip J; Silliman, Christopher C; Armour, Sarah; Wittwer, Erica D; Santrach, Paula J; Meade, Laurie A; Liedl, Lavonne M; Nieuwenkamp, Chelsea M; Douthit, Brian; van Buskirk, Camille M; Schulte, Phillip J; Kor, Daryl J

    2017-01-01

    Introduction The transfusion-related respiratory complications, transfusion-related acute lung injury (TRALI) and transfusion-associated circulatory overload (TACO), are leading causes of transfusion-related morbidity and mortality. At present, there are no effective preventive strategies with red blood cell (RBC) transfusion. Although mechanisms remain incompletely defined, soluble biological response modifiers (BRMs) within the RBC storage solution may play an important role. Point-of-care (POC) washing of allogeneic RBCs may remove these BRMs, thereby mitigating their impact on post-transfusion respiratory complications. Methods and analysis This is a multicenter randomised clinical trial of standard allogeneic versus washed allogeneic RBC transfusion for adult patients undergoing cardiac surgery testing the hypothesis that POC RBC washing is feasible, safe, and efficacious and will reduce recipient immune and physiologic responses associated with transfusion-related respiratory complications. Relevant clinical outcomes will also be assessed. This investigation will enrol 170 patients at two hospitals in the USA. Simon’s two-stage design will be used to assess the feasibility of POC RBC washing. The primary safety outcomes will be assessed using Wilcoxon Rank-Sum tests for continuous variables and Pearson chi-square test for categorical variables. Standard mixed modelling practices will be employed to test for changes in biomarkers of lung injury following transfusion. Linear regression will assess relationships between randomised group and post-transfusion physiologic measures. Ethics and dissemination Safety oversight will be conducted under the direction of an independent Data and Safety Monitoring Board (DSMB). Approval of the protocol was obtained by the DSMB as well as the institutional review boards at each institution prior to enrolling the first study participant. This study aims to provide important information regarding the feasibility of POC

  14. Environmental control during steam boiler washing

    Energy Technology Data Exchange (ETDEWEB)

    Guimaraes, Marcio A.B.; Abreu Pereira, Vera L. de [Companhia Petroquimica do Nordeste (COPENE), Camacari, BA (Brazil). Div. de Engenharia Ambiental; Ringler, Ulrich E.S. [PROMON Engenharia Ltda., Salvador, BA (Brazil)

    1994-12-31

    The washing and chemical cleaning of boilers, activities of a high polluting potential, are responsible for the generation of wastewater of high contents of heavy metals, suspended solids and chemical oxygen demand (COD). This paper describes the actions carried out by COPENE - Petroquimica do Nordeste S/A - in order to reduce this problem. (author). 10 refs., 3 figs., 2 tabs.

  15. Environmental control during steam boiler washing

    Energy Technology Data Exchange (ETDEWEB)

    Guimaraes, Marcio A.B.; Abreu Pereira, Vera L. de [Companhia Petroquimica do Nordeste (COPENE), Camacari, BA (Brazil). Div. de Engenharia Ambiental; Ringler, Ulrich E.S. [PROMON Engenharia Ltda., Salvador, BA (Brazil)

    1993-12-31

    The washing and chemical cleaning of boilers, activities of a high polluting potential, are responsible for the generation of wastewater of high contents of heavy metals, suspended solids and chemical oxygen demand (COD). This paper describes the actions carried out by COPENE - Petroquimica do Nordeste S/A - in order to reduce this problem. (author). 10 refs., 3 figs., 2 tabs.

  16. What Happens at a Car Wash?

    Science.gov (United States)

    Gallick, Barbara; Lee, Lisa

    2010-01-01

    A class of 3- to 5-year-old children in a child care center in the midwestern United States chose to study a car wash as a group project. This article discusses how the project evolved, describes the three phases of the project, and provides the teachers' reflections on the project. Photos taken during the project and children's sketches are…

  17. Effectiveness of a nonrinse, alcohol-free antiseptic hand wash.

    Science.gov (United States)

    Moadab, A; Rupley, K F; Wadhams, P

    2001-06-01

    This study evaluated the efficacy of a novel surfactant, allantoin, and benzalkonium chloride hand sanitizer using the US Food and Drug Administration's method for testing antiseptic hand washes that podiatric physicians and other health-care personnel use. The alcohol-free product, HandClens, was compared with an alcohol-based product, Purell. Independent researchers from the California College of Podiatric Medicine conducted the study using 40 volunteer students from the class of 2001. The results show that HandClens outperformed Purell and met the regulatory requirements for a hand sanitizer. Purell failed as an antimicrobial hand wash and was less effective than a control soap used in the study.

  18. Bladder wash cytology, quantitative cytology, and the qualitative BTA test in patients with superficial bladder cancer

    NARCIS (Netherlands)

    van der Poel, H. G.; van Balken, M. R.; Schamhart, D. H.; Peelen, P.; de Reijke, T.; Debruyne, F. M.; Schalken, J. A.; Witjes, J. A.

    1998-01-01

    Two new methods for the detection of transitional tumor cells in bladder wash (karyometry: QUANTICYT) and voided urine material (BARD BTA test) were compared with bladder wash cytology for the prediction of histology and tumor recurrence. Bladder wash material and voided urine were sampled from 138

  19. Remediation of cadmium- and lead-contaminated agricultural soil by composite washing with chlorides and citric acid.

    Science.gov (United States)

    Li, Yu-jiao; Hu, Peng-jie; Zhao, Jie; Dong, Chang-xun

    2015-04-01

    Composite washing of cadmium (Cd)- and lead (Pb)-contaminated agricultural soil from Hunan province in China using mixtures of chlorides (FeCl3, CaCl2) and citric acid (CA) was investigated. The concentrations of composite washing agents for metal removal were optimized. Sequential extraction was conducted to study the changes in metal fractions after soil washing. The removal of two metals at optimum concentration was reached. Using FeCl3 mixed with CA, 44% of Cd and 23% of Pb were removed, and 49 and 32% by CaCl2 mixed with CA, respectively. The mechanism of composite washing was postulated. A mixture of chlorides and CA enhanced metal extraction from soil through the formation of metal-chloride and metal-citrate complexes. CA in extract solutions promoted the formation of metal-chloride complexes and reduced the solution pH. Composite washing reduced Cd and Pb in Fe-Mn oxide forms significantly. Chlorides and CA exerted a synergistic effect on metal extraction during composite washing.

  20. Clay-oil flocculation during surf washing at the Sea Empress incident

    International Nuclear Information System (INIS)

    Wood, P.; Lunel, T.; Bailey, N.; Lee, K.

    1997-01-01

    Results of investigations into clay-oil flocculation during surf washing of oiled cobbles at Marros Beach, as a response to oiling during the Sea Empress incident, were summarized. Stranded oil on the cobble storm beach was found to associate with fine minerals and form flocs when introduced into sea water. The emulsions persisted for about 14 days after the oiling, after which it begun to disintegrate. After 50 days the remaining emulsion was found to be unstable and penetrated the beach to depths of up to three meters. Since no evidence of biodegradation was found during this period, oil reduction was attributed to sheening, facilitated by tidal fluctuations. Surf washing operation was undertaken over a seven day period beginning 47 days after the spill. Some 8150 tonnes of oiled cobbles were moved a distance of between 12 and 18 m seaward along a length of 850 m. Analysis of samples after two days following surf washing showed that oil concentration did not exceed 22 ppm, compared to 700 ppm before relocation. The significant reduction was considered to have been the result of enhanced oil dispersion coupled with the effects of the surf washing operations. 10 refs., 7 tabs., 10 figs

  1. Exploratory Disposal and Reuse Feasibility Analysis of Winter Maintenance Wash Water.

    Science.gov (United States)

    Ullinger, Heather L; Kennedy, Marla J; Schneider, William H; Miller, Christopher M

    2016-01-01

    The Ohio Department of Transportation has more than 60 facilities without sewer access generating approximately 19 million gallons of winter maintenance wash water. Off-site disposal is costly, creating the need for sustainable management strategies. The objective of this study was to conduct an exploratory feasibility analysis to assess wash water disposal and potential reuse as brine. Based on a comprehensive literature review and relevant environmental chemistry, a sampling protocol consisting of 31 water quality constituents was utilized for monthly sampling at three geographically distinct Ohio Department of Transportation garages during the winter of 2012. Results were compared to local disposal and reuse guidance limits. Three constituents, including a maximum copper concentration of 858 ppb, exceeded disposal limits, and many constituents also failed to meet reuse limits. Some concentrations were orders of magnitude higher than reuse limits and suggest pre-treatment would be necessary if wash water were reused as brine. These water quality results, in conjunction with copper chemical equilibrium modeling, show pH and dissolved carbon both significantly impact the total dissolved copper concentration and should be measured to assess reuse potential. The sampling protocol and specific obstacles highlighted in this paper aid in the future development of sustainable wash water management strategies.

  2. Exploratory Disposal and Reuse Feasibility Analysis of Winter Maintenance Wash Water.

    Directory of Open Access Journals (Sweden)

    Heather L Ullinger

    Full Text Available The Ohio Department of Transportation has more than 60 facilities without sewer access generating approximately 19 million gallons of winter maintenance wash water. Off-site disposal is costly, creating the need for sustainable management strategies. The objective of this study was to conduct an exploratory feasibility analysis to assess wash water disposal and potential reuse as brine. Based on a comprehensive literature review and relevant environmental chemistry, a sampling protocol consisting of 31 water quality constituents was utilized for monthly sampling at three geographically distinct Ohio Department of Transportation garages during the winter of 2012. Results were compared to local disposal and reuse guidance limits. Three constituents, including a maximum copper concentration of 858 ppb, exceeded disposal limits, and many constituents also failed to meet reuse limits. Some concentrations were orders of magnitude higher than reuse limits and suggest pre-treatment would be necessary if wash water were reused as brine. These water quality results, in conjunction with copper chemical equilibrium modeling, show pH and dissolved carbon both significantly impact the total dissolved copper concentration and should be measured to assess reuse potential. The sampling protocol and specific obstacles highlighted in this paper aid in the future development of sustainable wash water management strategies.

  3. Monitoring of well integrity by magnetic imaging defectoscopy (MID) at the Ketzin pilot site, Germany

    Science.gov (United States)

    Zemke, Kornelia; Liebscher, Axel; Möller, Fabian

    2017-04-01

    One of the key requirements for safe CO2 storage operation is to ensure wellbore integrity. The CO2 triggered acid in-well environment may lead to pitting and/or surface corrosion and eventually to fatigue of well casings and cementation by this giving raise to wellbore leakage. Corrosion effects are conventionally monitored by measurement of inner casing surface, internal diameter and wall thickness. Caliper logging provides inner surface and internal diameter data while ultrasonic tools measure both the internal diameter and casing thickness as well as the bonding between casing and cement. However, both tools can only monitor and characterize the most inner casing and ultrasonic tools in addition can only be applied in fluid filled wells. At the Ketzin CO2 storage test site, Germany, about 67 kt of CO2 were injected between June 2008 and August 2013 and an interdisciplinary monitoring concept was developed with focus on the storage complex, the overburden, the surface and the wellbores. Four deep wells penetrate the reservoir and their integrity has been monitored by a combination of video inspection, pulsed neutron gamma logging PNG and magnetic imaging defectoscopy MID. MID is an advanced logging method for non-destructive testing and has the great advantages that it can be operated in gas filled boreholes and that it provides information also for outer casings. The MID tool generates electromagnetic pulsed transient eddy currents and records the response of the surrounding media. The distribution and strength of the eddy-currents is then converted into averaged, depth-resolved thicknesses of the individual casings. Run in time-lapse mode, MID provides a measure to detect changes in casing thickness and therefore hints to corrosion. At Ketzin, the four deep wells haven been monitored by repeat MID logging on a roughly annual basis in cooperation with VNG Gasspeicher GmbH (VGS) and GAZPROMENERGODIAGNOSTIKA, applying their in-house MID tool. The MID based depth

  4. Countercurrent soil washing system for remediation of viscous hydrocarbons, heavy metals, radionuclides

    International Nuclear Information System (INIS)

    Kuhlman, M.I.; Karlsson, M.K.; Downie, C.A.

    1995-01-01

    Drying augers and multicell DAF tanks are excellent machines in which to countercurrently wash soil and remove hazardous hydrocarbons, metals or radionuclides. An auger works well because it preferentially moves soil along one side of its trough. Thus, when enough high pressure and temperature water jets are placed along that path, contaminants can be melted, or dissolved and scoured from the soil. Contaminants and fines flow down the opposite side of the auger and out for extraction in a series of flotation tanks. Countercurrent washing of the silt results when soil settles in tanks through rising water and air bubbles then is pumped through cyclones placed above the next DAF tank of the series. LNAPLs, DNAPLs, or metallic contaminants made hydrophobic by chemicals in the system are removed at the overflow of the cyclones or by flotation in the tanks. The overflow from the cyclones and DAF tanks flows into the previous tank of the series. Examples of contaminants remediated include; arsenic, cadmium, lead and mercury, Naturally Occurring Radioactive Materials (NORM), uranium, solid oils, polyaromatic hydrocarbons in creosote and coal tars, and polychlorinated hydrocarbons

  5. Little Puerco Wash-Catalpa Canyon Floodplain Management Study

    Data.gov (United States)

    Earth Data Analysis Center, University of New Mexico — The City of Gallup requested the Soil Conservation Service, through the McKinley Soil and Water Conservation District, to conduct a study of the Little Puerco Wash...

  6. Assessment of Washing with Antioxidant on the Oxidative Stability of Fatty Fish Mince during Processing and Storage

    DEFF Research Database (Denmark)

    Eymard, Sylvie; Jacobsen, Charlotte; Baron, Caroline

    2010-01-01

    Fatty fish have been recognized as potential raw material for the production of surimi; however, they can easily oxidize. The ability of antioxidants added in the washing water to reduce oxidation during the washing and subsequent storage needs to be evaluated. Horse mackerel (Trachurus trachurus...... performed. Results indicated that the antioxidants were accumulated differently, but all antioxidants tested were able to prevent lipid oxidation in fatty fish mince during washing and subsequent storage. The ranking in terms of oxidative stability of the washed minces was CA = PG > SP > W. The antioxidants......) mince was washed three times with 3 volumes of cold water (W) or the antioxidant solutions caffeic acid (CA) or propyl gallate (PG), at concentrations of 100 mg/kg, or spermine (SP), at a concentration of 400 mg/kg. Accumulation of antioxidant in the mince at each washing step was evaluated...

  7. A novel reverse-osmosis wash water recycle system for manned space stations

    Science.gov (United States)

    Ray, R. J.; Babcock, W. C.; Barss, R. P.; Andrews, T. A.; Lachapelle, E. D.

    1984-01-01

    The preliminary development of a wash water recycle system utilizing an inside-skinned hollow-fiber membrane is described. This module configuration is based on tube-side feed and is highly resistant to fouling with a minimum of pretreatment. During an ongoing research program for NASA, these modules were operated on actual wash waters with no significant fouling for a period of 40 days. Due to the tube-side-feed flow in these hollow-fiber membranes, the fibers themselves become the pressure vessels, allowing the development of extremely lightweight membrane modules. During the NASA research program, a pre-prototype membrane module capable of processing 6 gallons per day of wash water at 97 percent recovery was developed that can be dry-stored and that weighs 120 g.

  8. Y-12 Groundwater Protection Program Monitoring Optimization Plan for Groundwater Monitoring Wells at the U.S. Department of Energy Y-12 National Security Complex

    International Nuclear Information System (INIS)

    2006-01-01

    This document is the monitoring optimization plan for groundwater monitoring wells associated with the U.S. Department of Energy (DOE) Y-12 National Security Complex (Y-12) in Oak Ridge, Tennessee (Figure A.1). The plan describes the technical approach that will be implemented under the Y-12 Groundwater Protection Program (GWPP) to focus available resources on the monitoring wells at Y-12 that provide the most useful hydrologic and water-quality monitoring data. The technical approach is based on the GWPP status designation for each well (Section 2.0). Under this approach, wells granted ''active'' status are used by the GWPP for hydrologic monitoring and/or groundwater quality sampling (Section 3.0), whereas wells granted ''inactive'' status are not used for either purpose. The status designation also defines the frequency at which the GWPP will inspect applicable wells, the scope of these well inspections, and extent of any maintenance actions initiated by the GWPP (Section 3.0). Details regarding the ancillary activities associated with implementation of this plan (e.g., well inspection) are deferred to the referenced GWPP plans and procedures (Section 4.0). This plan applies to groundwater wells associated with Y-12 and related waste management areas and facilities located within three hydrogeologic regimes (Figure A.1): the Bear Creek Hydrogeologic Regime (Bear Creek Regime), the Upper East Fork Poplar Creek Hydrogeologic Regime (East Fork Regime), and the Chestnut Ridge Hydrogeologic Regime (Chestnut Ridge Regime). The Bear Creek Regime encompasses a section of Bear Creek Valley (BCV) immediately west of Y-12. The East Fork Regime encompasses most of the Y-12 process, operations, and support facilities in BCV and, for the purposes of this plan, includes a section of Union Valley east of the DOE Oak Ridge Reservation (ORR) boundary along Scarboro Road. The Chestnut Ridge Regime encompasses a section of Chestnut Ridge directly south of Y-12 that is bound on the

  9. Influence of selected washing treatments and drying temperatures ...

    African Journals Online (AJOL)

    Influence of selected washing treatments and drying temperatures on ... with regard to the optimal retention of the crude protein and fat levels of the dried dagaa. ... are accessible to most of the households involved in dried fish processing.

  10. Effect of number and washing solutions on functional properties of surimi-like material from duck meat.

    Science.gov (United States)

    Ramadhan, Kurnia; Huda, Nurul; Ahmad, Ruzita

    2014-02-01

    Duck meat is less utilized than other meats in processed products because of limitations of its functional properties, including lower water holding capacity, emulsion stability, and higher cooking loss compared with chicken meat. These limitations could be improved using surimi technology, which consists of washing and concentrating myofibrillar protein. In this study, surimi-like materials were made from duck meat using two or three washings with different solutions (tap water, sodium chloride, sodium bicarbonate, and sodium phosphate buffer). Better improvement of the meat's functional properties was obtained with three washings versus two washings. Washing with tap water achieved the highest gel strength; moderate elevation of water holding capacity, pH, lightness, and whiteness; and left a small amount of fat. Washing with sodium bicarbonate solution generated the highest water holding capacity and pH and high lightness and whiteness values, but it resulted in the lowest gel strength. Processing duck meat into surimi-like material improves its functional properties, thereby making it possible to use duck meat in processed products.

  11. Simulation of flow in the unsaturated zone beneath Pagany Wash, Yucca Mountain

    International Nuclear Information System (INIS)

    Kwicklis, E.M.; Healy, R.W.; Flint, A.L.

    1994-01-01

    A one-dimensional numerical model was created to simulate water movement beneath Pagany Wash, Yucca Mountain, Nevada. Model stratigraphy and properties were based on data obtained from boreholes UE-25 UZ No. 4 and UE-25 UZ No. 5, which was drilled in the alluvial channel and bedrock sideslope of Pagany Wash. Although unable to account for multidimensional or preferential flowpaths beneath the wash, the model proved a useful conceptual tool with which to develop hypotheses and, in some cases, provide bounding calculations. The model indicated that liquid flux decreases with depth in the upper 120 m beneath the wash, with fluxes of several tens mm/yr in the nonwelded base of the Tiva Canyon Member and fluxes on the order of a tenth mm/yr in the upper Topopah Spring Member. Capillary barrier effects were indicated by the model to significantly delay the entry of large fluxes into the potential repository horizon during periods of increasing net infiltration, and to inhibit rapid drainage of water from the nonwelded and bedded intervals into the potential repository horizon during periods of moisture redistribution. Lateral moisture redistribution can be expected to be promoted by these effects

  12. Geopolymerisation of silt generated from construction and demolition waste washing plants.

    Science.gov (United States)

    Lampris, C; Lupo, R; Cheeseman, C R

    2009-01-01

    Recycling plants that size, sort and wash construction and demolition waste can produce high quality aggregate. However, they also produce up to 80ton per hour of filter cake waste containing fine (waste and normally landfilled. This research investigated the potential to form geopolymers containing silt, which would allow this problematic waste to be beneficially reused as aggregate. This would significantly improve the economic viability of recycling plants that wash wastes. Silt filter cakes have been collected from a number of aggregate washing plants operating in the UK. These were found to contain similar aluminosilicate crystalline phases. Geopolymer samples were produced using silt and silt mixed with either metakaolin or pulverised fuel ash (PFA). Silt geopolymers cured at room temperature had average 7-day compressive strengths of 18.7MPa, while partial substitution of silt by metakaolin or PFA increased average compressive strengths to 30.5 and 21.9MPa, respectively. Curing specimens for 24h at 105 degrees C resulted in a compressive strength of 39.7MPa and microstructural analysis confirmed the formation of dense materials. These strengths are in excess of those required for materials to be used as aggregate, particularly in unbound applications. The implications of this research for the management of waste silt at construction and demolition waste washing plants are discussed.

  13. Regular use of a hand cream can attenuate skin dryness and roughness caused by frequent hand washing

    Directory of Open Access Journals (Sweden)

    Kampf Günter

    2006-02-01

    Full Text Available Abstract Background Aim of the study was to determine the effect of the regular use of a hand cream after washing hands on skin hydration and skin roughness. Methods Twenty-five subjects washed hands and forearms with a neutral soap four times per day, for 2 minutes each time, for a total of two weeks. One part of them used a hand cream after each hand wash, the others did not (cross over design after a wash out period of two weeks. Skin roughness and skin hydration were determined on the forearms on days 2, 7, 9 and 14. For skin roughness, twelve silicon imprint per subject and time point were taken from the stratum corneum and assessed with a 3D skin analyzer for depth of the skin relief. For skin hydration, five measurements per subject and time point were taken with a corneometer. Results Washing hands lead to a gradual increase of skin roughness from 100 (baseline to a maximum of 108.5 after 9 days. Use of a hand cream after each hand wash entailed a decrease of skin roughness which the lowest means after 2 (94.5 and 14 days (94.8. Skin hydration was gradually decreased after washing hands from 79 (baseline to 65.5 after 14 days. The hand wash, followed by use of a hand cream, still decreased skin hydration after 2 days (76.1. Over the next 12 days, however, skin hydration did not change significantly (75.6 after 14 days. Conclusion Repetitive and frequent hand washing increases skin dryness and roughness. Use of a hand cream immediately after each hand wash can confine both skin dryness and skin roughness. Regular use of skin care preparations should therefore help to prevent both dry and rough skin among healthcare workers in clinical practice.

  14. Metal (Cu, Cd and Zn) removal and stabilization during multiple soil washing by saponin.

    Science.gov (United States)

    Gusiatin, Zygmunt Mariusz; Klimiuk, Ewa

    2012-01-01

    The influence of multiple saponin washing on copper, cadmium and zinc removal and stability in three types of soils (loamy sand, loam, silty clay) was investigated. Distribution of metals and their mobility measured as the ratio of exchangeable form to the sum of all fractions in soils was differential. After single washing the highest efficiency of metal removal was obtained in loamy sand (82-90%) and loam (67-88%), whereas the lowest in silty clay (39-62%). In loamy sand and loam metals had higher mobility factors (44-61% Cu, 60-76% Cd, and 68-84% Zn) compared to silty clay (9% Cu, 28% Cd and 36% Zn). Triplicate washing led to increase both efficiency of metal removal and percentage content of their stable forms. In consequence, fractional patterns for metals before and after treatment changed visibly as a result of their redistribution. Based on the redistribution index, the most stable metal (mainly in residual and organic fractions) after triplicate washing was Cu in loamy sand and loam. For silty clay contaminated with Cd, effective metal removal and its stabilization required a higher number of washings. Copyright © 2011 Elsevier Ltd. All rights reserved.

  15. Effects of lead mineralogy on soil washing enhanced by ferric salts as extracting and oxidizing agents.

    Science.gov (United States)

    Yoo, Jong-Chan; Park, Sang-Min; Yoon, Geun-Seok; Tsang, Daniel C W; Baek, Kitae

    2017-10-01

    In this study, we evaluated the feasibility of using ferric salts including FeCl 3 and Fe(NO 3 ) 3 as extracting and oxidizing agents for a soil washing process to remediate Pb-contaminated soils. We treated various Pb minerals including PbO, PbCO 3 , Pb 3 (CO 3 ) 2 (OH) 2 , PbSO 4 , PbS, and Pb 5 (PO 4 ) 3 (OH) using ferric salts, and compared our results with those obtained using common washing agents of HCl, HNO 3 , disodium-ethylenediaminetetra-acetic acid (Na 2 -EDTA), and citric acid. The use of 50 mM Fe(NO 3 ) 3 extracted significantly more Pb (above 96% extraction) from Pb minerals except PbSO 4 (below 55% extraction) compared to the other washing agents. In contrast, washing processes using FeCl 3 and HCl were not effective for extraction from Pb minerals because of PbCl 2 precipitation. Yet, the newly formed PbCl 2 could be dissolved by subsequent wash with distilled water under acidic conditions. When applying our washing method to remediate field-contaminated soil from a shooting range that had high concentrations of Pb 3 (CO 3 ) 2 (OH) 2 and PbCO 3 , we extracted more Pb (approximately 99% extraction) from the soil using 100 mM Fe(NO 3 ) 3 than other washing agents at the same process conditions. Our results show that ferric salts can be alternative washing agents for Pb-contaminated soils in view of their extracting and oxidizing abilities. Copyright © 2017 Elsevier Ltd. All rights reserved.

  16. SOIL WASHING TREATABILITY TESTS FOR PESTICIDE- CONTAMINATED SOIL

    Science.gov (United States)

    The 1987 Sand Creek Operable Unit 5 record of decision (ROD) identified soil washing as the selected technology to remediate soils contaminated with high levels of organochlorine pesticides, herbicides, and metals. Initial treatability tests conducted to assess the applicability...

  17. Gunite and associated tanks dry well conductivity monitoring report, Oak Ridge National Laboratory, Oak Ridge, Tennessee, February 1998 - December 1998

    International Nuclear Information System (INIS)

    1999-04-01

    A waste removal program is being implemented for the Gunite and Associated Tanks Operable Unit at Oak Ridge National Laboratory, Oak Ridge, Tennessee. The waste is being removed by means of remotely operated, in-tank, confined sluicing equipment. During sluicing operations the dry wells adjacent to each of the tanks are instrumented so that potential releases can be detected by means external to the tank. The method of detection is by monitoring the electrical conductivity of the water in the dry well associated with each tank. This report documents the dry well conductivity monitoring data for the period from February 1998 through December 1998. The dry wells monitored during this period include DW-5, DW-6, DW-7, DW-8, DW-9 and DW-10. The conductivity of the water passing through Pump Station 1 (PS1) was also monitored. During this period the sluicing activities at Tank W-6 were initiated and successfully completed. In addition, flight mixers were used to remove wastes from Tank W-5, and sluicing operations were initiated on Tank W-7. Presented in this report are the dry well conductivity, rainfall, tank level, and other appropriate information relevant to the analysis and interpretation of the monitoring data for the reporting period. A thorough analysis of the monitoring results from the six dry wells in the STF and PS1 for the period between February 1998 and December 1998 indicates that no releases have occurred from the gunite tanks being monitored. Overall, the dry well conductivity monitoring continues to provide a robust and sensitive method for detecting potential releases from the gunite tanks and for monitoring seasonal and construction-related changes in the dry well and drain system

  18. Monitoring of overalls and personnel skin contamination

    International Nuclear Information System (INIS)

    Turkin, N.F.

    1980-01-01

    Organization of monitoring of overalls and personnel skin contamination wastes is considered. The devices used for this purpose are enumerated. In sanitary sluices through which the personnel leaving the repair zone it is recommended to particularly thoroughly control hand skin contamination and most contaminated parts of overalls (sleeves, breeches lower parts, pockets, stomack region). In sanitary check points during personnel leaving the operator zone monitoring of overalls and skin contamination is performed. The overalls and other individual protective clothing are subjected to control in a special loundry before and after washing (decontamination) [ru

  19. Experimental evaluation of washing for treatment of combustible plutonium-contaminated materials

    International Nuclear Information System (INIS)

    Wilkins, J.D.; Wisbey, S.J.

    1983-03-01

    Laboratory scale experiments have been carried out in order to assess the potential of washing as a method for removing plutonium from contaminated combustible wastes. A wide range of aqueous (eg 1 M HNO 3 , 1 M NaOH) and organic (1,1,2-trichlorotrifluoroethane) reagents have been investigated. Both synthetically contaminated and real wastes have been investigated. The preferred wash reagent has been identified as 1 M sodium hydroxide solution; plutonium recoveries of ca.80 to 90% can be achieved. (author)

  20. Bacterial flora of processed broiler chicken skin after successive washings in mixtures of potassium hydroxide and lauric acid.

    Science.gov (United States)

    Hinton, Arthur; Cason, John A

    2008-08-01

    Changes in the size of populations of different groups of bacteria composing the normal flora of processed broiler skin were examined after each of five consecutive washings in mixtures of potassium hydroxide (KOH) and lauric acid (LA). Portions of skin from commercially processed broiler carcasses were washed in distilled water (control) or in mixtures of 0.25% KOH-0.5% LA or 0.5% KOH-1% LA by using a stomacher laboratory blender to agitate the skin in the solutions. After each wash, skin was transferred to fresh solutions, and washing was repeated to provide samples washed one to five times in each solution. Bacteria in rinsates of the washed skin were enumerated on plate count (PC) agar, Staphylococcus (STA) agar, Levine eosin methylene blue (EMB) agar, lactic acid bacteria (LAB) agar, and Perfringens (PER) agar with TSC supplement. Selected isolates recovered on each medium were identified. Overall, no significant differences were observed in numbers of bacteria recovered on PC, STA, or EMB agars from skin after repeated washing in water, but there were significant reductions in the number of bacteria recovered on LAB and PER agars. Repeated washing of skin in 0.25% KOH-0.5% LA or 0.5% KOH-1% LA generally produced significant reductions in the number of bacteria recovered on all media. Furthermore, no bacteria were recovered on PER agar from skin washed five times in 0.25% KOH-0.5% LA. Likewise, no bacteria were recovered on EMB or LAB agars from skin washed three or more times in 0.5% KOH-1% LA or on PER agar from skin washed four or five times in this solution. Staphylococcus spp. were identified as the skin isolates with the highest degree of resistance to the bactericidal activity of KOH-LA. Findings indicate that although bacteria may be continually shed from poultry skin after repeated washings, bactericidal surfactants can be used to remove and kill several types of bacteria found on the surface of the skin of processed broilers.

  1. The study of road surface micro-texture's effects for the pavement's decontamination by high pressure water washing

    International Nuclear Information System (INIS)

    Kobayashi, Masatoshi; Shimizu, Tadaaki; Hirayama, Takahiro

    2014-01-01

    In the result of “decontamination technical demonstration project” by Ministry of the Environment, it has became clear that the effect variation is larger in high pressure water washing method, compared with others in road surface decontamination technology. In this study, we have hypothesized the fact at the difference of micro-texture of the road surface, by carrying out high pressure water washing method in different kinds of road surfaces and verified the relation between washing efficiency and micro-texture road surface. Positive correlation has admitted between the washing number of times and radiation reduction rate and the trend of primary regression equation (i.e. radiation reduction rate per washing time) is indicating that decreasing tendency of radiation carried by the increasing of micro-texture of the road surface. Here, we proposed the method to estimated essential washing number of times to achieve the targeted radiation reduction rate from the relation of that trend and micro-texture of the road surface. (author)

  2. Enhanced post wash retention of combed DNA molecules by varying multiple combing parameters.

    Science.gov (United States)

    Yadav, Hemendra; Sharma, Pulkit

    2017-11-01

    Recent advances in genomics have created a need for efficient techniques for deciphering information hidden in various genomes. Single molecule analysis is one such technique to understand molecular processes at single molecule level. Fiber- FISH performed with the help of DNA combing can help us in understanding genetic rearrangements and changes in genome at single DNA molecule level. For performing Fiber-FISH we need high retention of combed DNA molecules post wash as Fiber-FISH requires profuse washing. We optimized combing process involving combing solution, method of DNA mounting on glass slides and coating of glass slides to enhance post-wash retention of DNA molecules. It was found that average number of DNA molecules observed post-wash per field of view was maximum with our optimized combing solution. APTES coated glass slides showed lesser retention than PEI surface but fluorescent intensity was higher in case of APTES coated surface. Capillary method used to mount DNA on glass slides also showed lesser retention but straight DNA molecules were observed as compared to force flow method. Copyright © 2017 Elsevier Inc. All rights reserved.

  3. Domestic wash water reclamation for reuse as commode water supply using filtration: Reverse-osmosis separation technique

    Science.gov (United States)

    Hall, J. B., Jr.; Batten, C. E.; Wilkins, J. R.

    1974-01-01

    A combined filtration-reverse-osmosis water recovery system has been evaluated to determine its capability to reclaim domestic wash water for reuse as a commode water supply. The system produced water that met all chemical and physical requirements established by the U.S. Public Health Service for drinking water with the exception of carbon chloroform extractables, methylene blue active substances, and phenols. It is thought that this water is of sufficient quality to be reused as commode supply water. The feasibility of using a combined filtration and reverse-osmosis technique for reclaiming domestic wash water has been established. The use of such a technique for wash-water recovery will require a maintenance filter to remove solid materials including those less than 1 micron in size from the wash water. The reverse-osmosis module, if sufficiently protected from plugging, is an attractive low-energy technique for removing contaminants from domestic wash water.

  4. Y-12 Groundwater Protection Program Monitoring Optimization Plan for Groundwater Monitoring Wells at the U.S. Department of Energy Y-12 National Security Complex, Oak Ridge, Tennessee

    Energy Technology Data Exchange (ETDEWEB)

    None

    2003-09-30

    This document is the monitoring optimization plan for groundwater monitoring wells associated with the U.S. Department of Energy (DOE) Y-12 National Security Complex (Y-12) in Oak Ridge, Tennessee (Figure 1). The plan describes the technical approach that will be implemented under the Y-12 Groundwater Protection Program (GWPP) to focus available resources on the monitoring wells at Y-12 which provide the most useful hydrologic and water-quality monitoring data. The technical approach is based on the GWPP status designation for each well (Section 2.0). Under this approach, wells granted ''active'' status are used by the GWPP for hydrologic monitoring and/or groundwater sampling (Section 3.0), whereas well granted ''inactive'' status are not used for either purpose. The status designation also determines the frequency at which the GWPP will inspect applicable wells, the scope of these well inspections, and extent of any maintenance actions initiated by the GWPP (Section 4.0). Details regarding the ancillary activities associated with implementation of this plan (e.g., well inspection) are deferred to the referenced GWPP plans and procedures (Section 5.0). This plan applies to groundwater monitoring wells associated with Y-12 and related waste management facilities located within three hydrogeologic regimes (Figure 1): the Bear Creek Hydrogeologic Regime (Bear Creek Regime), the Upper East Fork Poplar Creek Hydrogeologic Regime (East Fork Regime), and the Chestnut Ridge Hydrogeologic Regime (Chestnut Ridge Regime). The Bear Creek Regime encompasses a section of Bear Creek Valley (BCV) immediately west of Y-12. The East Fork Regime encompasses most of the Y-12 process, operations, and support facilities in BCV and, for the purposes of this plan, includes a section of Union Valley east of the DOE Oak Ridge Reservation (ORR) boundary along Scarboro Road. The Chestnut Ridge Regime is directly south of Y-12 and encompasses a section of Chestnut Ridge that is bound to the

  5. Voided urine versus bladder washing cytology for detection of urothelial carcinoma: which is better?

    Science.gov (United States)

    Keller, Anna Krarup; Jensen, Jørgen Bjerggaard

    2017-08-01

    Cytology is recommended as part of the follow-up of high-grade non-muscle-invasive bladder cancer (NMIBC). However, currently there are no solid guideline recommendations regarding the use of voided urine versus bladder washing for cytology as part of the diagnosis or follow-up of NMIBC. The aim of this study was to investigate whether the cytological outcome was equal regarding the two techniques. The authors reviewed all outpatient flexible cystoscopies carried out in their department in 2013. Patient records in the registry of pathology were examined and those with simultaneous urine and bladder washing cytology were included. Previous urothelial disease and positive histology within 3 months after the cystoscopy were registered. A total of 1458 patients had both voided urine and bladder washing cytology and were included in the study, of whom 643 (44%) had a history of urothelial disease. An equal outcome of urine and bladder washing cytology was found in 1447 patients (99.2%). For the remaining 11 patients, only four patients underwent further examinations based on cytology findings in addition to what had already been planned after cystoscopy. Of the included patients, 100 (6.9%) had a positive histological outcome within 3 months. In most patients, no relevant difference between voided urine and bladder washing cytology was observed. Therefore, if cytology is indicated, it is recommended to use the test that is most readily available locally. The additional gain in using both urine and bladder wash is minimal, and can therefore be discarded.

  6. A laboratory study of washing of SRS high-level waste radioactive sludge-evidence for insoluble sodium and cesium-137

    International Nuclear Information System (INIS)

    Hay, M.S.; Bibler, N.E.

    1994-01-01

    Experiments in the Shielded Cells at the Savannah River Technology Center were undertaken to simulate the full-scale sludge washing process and thereby identify potential problems, wash water requirements, sludge settling rates and the fate of various radioactive and non-radioactive species present in the sludge. The laboratory sludge washing experiments were conducted on a radioactive sludge sample taken from one of three processing tanks in Extended Sludge Processing. The sample of Tank 42H sludge was extensively characterized for both soluble and insoluble species (radioactive and non-radioactive) before beginning the washing study. The results of the washing experiments using inhibited water (0.01 M NaOH) indicate there is essentially no dissolution of species from the insoluble phase of the sludge during the washing. The addition of wash water to the sludge merely dilutes the salt dissolved in the interstitial supernate of the sludge. Another result from the experiments is that approximately 30% of the sodium and 86% of the Cs-137 in the original unwashed sludge is present in an insoluble form and does not wash out of the sludge

  7. Salmonella transfer during pilot plant scale washing and roller conveying of tomatoes.

    Science.gov (United States)

    Wang, Haiqiang; Ryser, Elliot T

    2014-03-01

    Salmonella transfer during washing and roller conveying of inoculated tomatoes was quantified using a pilot scale tomato packing line equipped with plastic, foam, or brush rollers. Red round tomatoes (2.3 kg) were dip inoculated with Salmonella enterica serovar Typhimurium LT2 (avirulent) (4 log CFU/g), air dried for 2 h, and then washed in sanitizer-free water for 2 min. Inoculated tomatoes were then passed single file over a 1.5-m conveyor equipped with plastic, foam, or brush rollers followed by 25 previously washed uninoculated tomatoes. Tomato samples were collected after 2 min of both washing and roller conveying, with all 25 uninoculated tomatoes collected individually after conveying. Roller surface samples were collected before and after conveying the uninoculated tomatoes. Both tomato and surface samples were quantitatively examined for Salmonella by direct plating or membrane filtration using xylose lysine Tergitol 4 agar. Regardless of the roller type, Salmonella populations on inoculated tomatoes did not significantly (P conveyors. After conveying uninoculated tomatoes over contaminated foam rollers, 96% of the 25 tomatoes were cross-contaminated with Salmonella at >100 CFU per tomato. With plastic rollers, 24 and 76% of tomatoes were cross-contaminated with Salmonella at 10 to 100 and 1 to 10 CFU per tomato, respectively. In contrast, only 8% of 25 tomatoes were cross-contaminated with brush rollers with Salmonella populations of 1 to 10 CFU per tomato. Overall, cross-contamination was greatest with foam, followed by plastic and brush rollers (P < 0.05). Adding peroxyacetic acid or chlorine to the wash water significantly decreased cross-contamination during tomato conveying, with chlorine less effective in controlling Salmonella on foam compared with plastic and brush rollers.

  8. [Preparation and antimicrobial effect of aromatic, natural and bacteriostatic foot wash with skin care].

    Science.gov (United States)

    Gao, Su-Hua; Zhao, Guo-Xiang; Yang, Xiao-Dong; Xu, Ling-Ling

    2013-06-01

    To prepare the aromatic, natural and bacteriostatic foot wash with skin care and research the inhibition effect on the different bacteria and pathogenic fungus which cause dermatophytosis. It was prepared by using Sophoraflavescens and Dictamnus dasycarpus as materials with the addition of Aloe extract, essential oil, surfactant, etc. The antifungal and antibacterial activity was researched by the levitation liquid quantitative method. The foot wash smelled faintly scent. The use of this product can produce a rich foam. The inhibitory rate were all more than 90%. The preparation process of the foot wash was simple. It has obviously bacteriostatic and fungistatic effect.

  9. Combined effectiveness of anthelmintic chemotherapy and WASH among HIV-infected adults.

    Directory of Open Access Journals (Sweden)

    Arianna R Means

    2018-01-01

    Full Text Available Current global helminth control guidelines focus on regular deworming of targeted populations for morbidity control. However, water, sanitation, and hygiene (WASH interventions may also be important for reducing helminth transmission. We evaluated the impact of different potential helminth protective packages on infection prevalence, including repeated treatment with albendazole and praziquantel with and without WASH access.We conducted a cohort study nested within a randomized trial of empiric deworming of HIV-infected adults in Kenya. Helminth infections and infection intensity were diagnosed using semi-quantitative real-time PCR. We conducted a manual forward stepwise model building approach to identify if there are packages of interventions that may be protective against an STH infection of any species (combined outcome and each helminth species individually. We conducted secondary analyses using the same approach only amongst individuals with no anthelmintis exposure. We used interaction terms to test for potential intervention synergy. Approximately 22% of the 701 stool samples provided were helminth-infected, most of which were of low to moderate intensity. The odds of infection with any STH species were lower for individuals who were treated with albendazole (aOR:0.11, 95%CI: 0.05, 0.20, p<0.001, adjusting for age and sex. Although most WASH conditions demonstrated minimal additional benefit in reducing the probability of infection with any STH species, access to safe flooring did appear to offer some additional protection (aOR:0.34, 95%CI: 0.20, 0.56, p<0.001. For schistosomiasis, only treatment with praziquantel was protective (aOR:0.30 95%CI: 0.14, 0.60, p = 0.001. Amongst individuals who were not treated with albendazole or praziquantel, the most protective intervention package to reduce probability of STH infections included safe flooring (aOR:0.34, 95%CI: 0.20, 0.59, p<0.001 and latrine access (aOR:0.59, 95%CI: 0.35, 0.99, p = 0

  10. Role of urban surface roughness in road-deposited sediment build-up and wash-off

    Science.gov (United States)

    Zhao, Hongtao; Jiang, Qian; Xie, Wenxia; Li, Xuyong; Yin, Chengqing

    2018-05-01

    Urban road surface roughness is one of the most important factors in estimation of surface runoff loads caused by road-deposited sediment (RDS) wash-off and design of its control measures. However, because of a lack of experimental data to distinguish the role of surface roughness, the effects of surface roughness on RDS accumulation and release are not clear. In this study, paired asphalt and concrete road surfaces and rainfall simulation designs were used to distinguish the role of surface roughness in RDS build-up and wash-off. Our results showed that typical asphalt surfaces often have higher depression depths than typical concrete surfaces, indicating that asphalt surfaces are relatively rougher than concrete surface. Asphalt surfaces can retain a larger RDS amount, relative higher percentage of coarser particles, larger RDS wash-off loads, and lower wash-off percentage, than concrete surfaces. Surface roughness has different effects in RDS motilities with different particle sizes during rainfall runoff, and the settleable particles (44-149 μm) were notably influenced by it. Furthermore, the first flush phenomenon tended to be greater on relatively smooth surfaces than relatively rough surfaces. Overall, surface roughness plays an important role in influencing the complete process of RDS build-up and wash-off on different road characteristics.

  11. A LARCH BIOREFINERY: INFLUENCE OF WASHING AND PS CHARGE ON PRE-EXTRACTION PSAQ PULPING

    Directory of Open Access Journals (Sweden)

    Hanna S. Hörhammer

    2012-06-01

    Full Text Available This study deals with a biorefinery concept based on larch wood. Wood chips of Siberian larch (Larix sibirica Lebed. were treated with water before pulping at the optimal pre-extraction (PE condition of 150 °C and 90 minutes. Through PE, about 12.4% of the wood mass is dissolved, mainly from the arabinogalactan hemicellulose component. Fermentation of the hemicellulose-rich larch extract with Bacillus coagulans resulted in consumption of all C6 and C5 sugars and produced lactic acid in high yield. PE before pulping resulted in lower (4 to 5% pulp yield than for control kraft pulps. However, the pulp yield loss may be reduced by addition of polysulfide (PS and anthraquinone (AQ. The present study focuses on the effect of the degree of washing of the extracted chips and that of the PS charge in PSAQ pulping on the final properties of the pulp. Three different levels of washing and three different PS charges were tested. The characteristics of the extract, wash water, pulp, and black liquor samples were determined. The amount of sugars in the combined stream of collected extract and wash water obtained by mild washing was 10.2% on o.d. wood.

  12. Design, placement, and sampling of groundwater monitoring wells for the management of hazardous waste disposal facilities

    International Nuclear Information System (INIS)

    Tsai, S.Y.

    1988-01-01

    Groundwater monitoring is an important technical requirement in managing hazardous waste disposal facilities. The purpose of monitoring is to assess whether and how a disposal facility is affecting the underlying groundwater system. This paper focuses on the regulatory and technical aspects of the design, placement, and sampling of groundwater monitoring wells for hazardous waste disposal facilities. Such facilities include surface impoundments, landfills, waste piles, and land treatment facilities. 8 refs., 4 figs

  13. Washing the patient: dignity and aesthetic values in nursing care.

    Science.gov (United States)

    Pols, Jeannette

    2013-07-01

    Dignity is a fundamental concept, but its meaning is not clear. This paper attempts to clarify the term by analysing and reconnecting two meanings of dignity: humanitas and dignitas. Humanitas refers to citizen values that protect individuals as equal to one another. Dignitas refers to aesthetic values embedded in genres of sociality that relate to differences between people. The paper explores these values by way of an empirical ethical analysis of practices of washing psychiatric patients in nursing care. Nurses legitimate the washing of reluctant patients with reference to dignity. The analysis shows the intertwinement of humanitas and dignitas that gives dignity its fundamental meaning. © 2013 John Wiley & Sons Ltd.

  14. GAAT dry well conductivity monitoring report, July 1997 through January 1998, Oak Ridge National Laboratory, Oak Ridge, Tennessee

    International Nuclear Information System (INIS)

    1998-01-01

    A waste removal program is being implemented for the Gunite and Associated Tanks (GAAT) Operable Unit at Oak Ridge National Laboratory (ORNL), Oak Ridge, Tennessee. The waste is being removed by means of remotely operated, in-tank, confined sluicing equipment. The waste removal operations in Tanks W-3 and W-4 in the North Tank Farm (NTF) have been completed and the equipment is being moved to the South Tank Farm (STF), where it will be used to remove the sludges from the six STF tanks (W-5, W-6, W-7, W-8, W-9, and W-10) beginning later this year. During sluicing operations the dry wells adjacent to each of the tanks are instrumented so that potential releases can be detected by means external to the tank. The method of detection is by monitoring the electrical conductivity of the water in the dry well associated with each tank. This report documents the dry well conductivity monitoring data for the period from July 1997 through January 1998. The dry wells monitored during this period include DW-3, DW-4, DW-8, DW-9, and DW-10. The conductivity of the water passing through Pump Station 1 (PS 1) was also monitored. The principal activities that occurred during this period were the sluicing of Tanks W-3 and W-4 in the NTF, transfer of tank liquids from the NTF to the STF, and the installation of new risers, tank dome leveling, and emplacement of stabilized base backfill in the STF. Presented in this report are the dry well conductivity, rainfall, tank level, and STF construction information that is relevant to the analysis and interpretation of the monitoring data for the reporting period. A thorough analysis of the monitoring results for the period indicates that no releases have occurred from the gunite tanks being monitored

  15. Assessment of washing procedure for determination some of ...

    African Journals Online (AJOL)

    This study was proposed to assess the suitability of washing technique to distinguish between airborne and soil borne several metal contaminants. For this reason, six plant species which grew under Mobarakeh Steel Company emissions were selected. Aluminum, iron, nickel, manganese, zinc, copper and lead ...

  16. Modified Core Wash Cytology: A reliable same day biopsy result for breast clinics.

    Science.gov (United States)

    Bulte, J P; Wauters, C A P; Duijm, L E M; de Wilt, J H W; Strobbe, L J A

    2016-12-01

    Fine Needle Aspiration Biopsy (FNAB), Core Needle biopsy (CNB) and hybrid techniques including Core Wash Cytology (CWC) are available for same-day diagnosis in breast lesions. In CWC a washing of the biopsy core is processed for a provisional cytological diagnosis, after which the core is processed like a regular CNB. This study focuses on the reliability of CWC in daily practice. All consecutive CWC procedures performed in a referral breast centre between May 2009 and May 2012 were reviewed, correlating CWC results with the CNB result, definitive diagnosis after surgical resection and/or follow-up. Symptomatic as well as screen-detected lesions, undergoing CNB were included. 1253 CWC procedures were performed. Definitive histology showed 849 (68%) malignant and 404 (32%) benign lesions. 80% of CWC procedures yielded a conclusive diagnosis: this percentage was higher amongst malignant lesions and lower for benign lesions: 89% and 62% respectively. Sensitivity and specificity of a conclusive CWC result were respectively 98.3% and 90.4%. The eventual incidence of malignancy in the cytological 'atypical' group (5%) was similar to the cytological 'benign' group (6%). CWC can be used to make a reliable provisional diagnosis of breast lesions within the hour. The high probability of conclusive results in malignant lesions makes CWC well suited for high risk populations. Copyright © 2016 Elsevier Ltd, BASO ~ the Association for Cancer Surgery, and the European Society of Surgical Oncology. All rights reserved.

  17. Towards a biological monitoring guidance value for acrylamide.

    Science.gov (United States)

    Sams, C; Jones, K; Warren, N; Cocker, J; Bell, S; Bull, P; Cain, M

    2015-08-19

    Acrylamide is classified as a potential human carcinogen and neurotoxicant. Biological monitoring is a useful tool for monitoring worker exposure. However, other sources of exposure to acrylamide (including cigarette smoke and diet) also need to be considered. This study has performed repeat measurements of the urinary mercapturic acids of acrylamide (AAMA) and its metabolite glycidamide (GAMA) and determined globin adducts in 20 production-plant workers at a UK acrylamide production facility. The relationship between biomarker levels and environmental monitoring data (air levels and hand washes) was investigated. Good correlations were found between all of the biomarkers (r(2)=0.86-0.91) and moderate correlations were found between the biomarkers and air levels (r(2) = 0.56-0.65). Our data show that urinary AAMA is a reliable biomarker of acrylamide exposure. Occupational hygiene data showed that acrylamide exposure at the company was well within the current UK Workplace Exposure Limit. The 90th percentile of urinary AAMA in non-smoking production-plant workers (537 μmol/mol creatinine (n = 59 samples)) is proposed as a possible biological monitoring guidance value. This 90th percentile increased to 798 μmol/mol if smokers were included (n = 72 samples). These values would be expected following an airborne exposure of less than 0.07 mg/m(3), well below the current UK workplace exposure limit of 0.3mg/m(3). Comparison of biomarker levels in non-occupationally exposed individuals suggests regional variations (between UK and Germany), possibly due to differences in diet. Crown Copyright © 2015. Published by Elsevier Ireland Ltd. All rights reserved.

  18. Cross-flow filtration during the washing of a simulated radioactive waste stream

    International Nuclear Information System (INIS)

    MARK R., DUIGNAN

    2005-01-01

    Bechtel National, Inc. has been contracted by the Department of Energy to design a Waste Treatment and Immobilization Plant (WTP) to stabilize liquid radioactive waste that is stored at the Hanford Site as part of the River Protection Project (RPP). Because of its experience with radioactive waste stabilization, the Savannah River National Laboratory (SRNL) of the Westinghouse Savannah River Company is working with Bechtel and Washington Group International, to help design and test certain parts of the waste treatment facility. One part of the process is the separation of radioactive solids from the liquid wastes by cross-flow ultrafiltration. To test this process a cross-flow filter was used that was prototypic in porosity, length, and diameter, along with a simulated radioactive waste slurry, made to prototypically represent the chemical and physical characteristics of a Hanford waste in tank 241-AY-102/C-106. To mimic the filtration process the waste slurry undergoes several steps, including dewatering and washing. During dewatering the concentration of undissolved solids (UDS) of the simulated AY102/C106 waste is increased from 12 wt percent to at least 20 wt percent. Once at the higher concentration the waste must be washed to prepare for its eventual receipt in a High Level Radioactive Waste Melter to be vitrified. This paper describes the process of washing and filtering a batch of concentrated simulated waste in two cycles, which each containing 22 washing steps that used approximately 7.7 liters of a solution of 0.01 M NaOH per step. This will be the method used by the full-scale WTP to prepare the waste for vitrification. The first washing cycle started with the simulated waste that had a solids concentration of 20 wt percent UDS. This cycle began with a permeate filter flux of 0.015 gpm/ft2 (3.68 cm/hr) at 19.6 wt percent UDS with a density of 1.33 kg/L, and yield stress of 8.5 Pa. At the end of the 22 washing steps the permeate filter flux increased to

  19. Rational risk-based decision support for drinking water well managers by optimized monitoring designs

    Science.gov (United States)

    Enzenhöfer, R.; Geiges, A.; Nowak, W.

    2011-12-01

    Advection-based well-head protection zones are commonly used to manage the contamination risk of drinking water wells. Considering the insufficient knowledge about hazards and transport properties within the catchment, current Water Safety Plans recommend that catchment managers and stakeholders know, control and monitor all possible hazards within the catchments and perform rational risk-based decisions. Our goal is to supply catchment managers with the required probabilistic risk information, and to generate tools that allow for optimal and rational allocation of resources between improved monitoring versus extended safety margins and risk mitigation measures. To support risk managers with the indispensable information, we address the epistemic uncertainty of advective-dispersive solute transport and well vulnerability (Enzenhoefer et al., 2011) within a stochastic simulation framework. Our framework can separate between uncertainty of contaminant location and actual dilution of peak concentrations by resolving heterogeneity with high-resolution Monte-Carlo simulation. To keep computational costs low, we solve the reverse temporal moment transport equation. Only in post-processing, we recover the time-dependent solute breakthrough curves and the deduced well vulnerability criteria from temporal moments by non-linear optimization. Our first step towards optimal risk management is optimal positioning of sampling locations and optimal choice of data types to reduce best the epistemic prediction uncertainty for well-head delineation, using the cross-bred Likelihood Uncertainty Estimator (CLUE, Leube et al., 2011) for optimal sampling design. Better monitoring leads to more reliable and realistic protection zones and thus helps catchment managers to better justify smaller, yet conservative safety margins. In order to allow an optimal choice in sampling strategies, we compare the trade-off in monitoring versus the delineation costs by accounting for ill

  20. Washing and Caustic Leaching of Hanford Tank Sludge: Results of FY 1998 Studies

    Energy Technology Data Exchange (ETDEWEB)

    GJ Lumetta; BM Rapko; J Liu; DJ Temer; RD Hunt

    1998-12-11

    Sludge washing and parametric caustic leaching tests were performed on sludge samples tiom five Hanford tanks: B-101, BX-1 10, BX-112, C-102, and S-101. These studies examined the effects of both dilute hydroxide washing and caustic leaching on the composition of the residual sludge solids. ` Dilute hydroxide washing removed from <1 to 25% of the Al, -20 to 45% of the Cr, -25 to 97% of the P, and 63 to 99% of the Na from the Hdord tank sludge samples examined. The partial removal of these elements was likely due to the presence of water-soluble sodium salts of aluminate, chromate, hydroxide, nitrate, nitrite, and phosphate, either in the interstitial liquid or as dried salts.

  1. Hand washing practices and the occurrence of enteropathogenic ...

    African Journals Online (AJOL)

    ... levels of compliance to hand washing and related this to the occurrence of infectious bacteria in the test population. A questionnaire which contained information on bio-demographic characteristics and hand hygiene practices was applied to 100 individuals in the study population. Microbiological samples were obtained, ...

  2. Heavy metal removal by GLDA washing: Optimization, redistribution, recycling, and changes in soil fertility.

    Science.gov (United States)

    Wang, Guiyin; Zhang, Shirong; Xu, Xiaoxun; Zhong, Qinmei; Zhang, Chuer; Jia, Yongxia; Li, Ting; Deng, Ouping; Li, Yun

    2016-11-01

    Soil washing, an emerging method for treating soils contaminated by heavy metals, requires an evaluation of its efficiency in simultaneously removing different metals, the quality of the soil following remediation, and the reusability of the recycled washing agent. In this study, we employed N,N-bis (carboxymethyl)-l-glutamic acid (GLDA), a novel and readily biodegradable chelator to remove Cd, Pb, and Zn from polluted soils. We investigated the influence of washing conditions, including GLDA concentration, pH, and contact time on their removal efficiencies. The single factor experiments showed that Cd, Pb, and Zn removal efficiencies reached 70.62, 74.45, and 34.43% in mine soil at a GLDA concentration of 75mM, a pH of 4.0, and a contact time of 60min, and in polluted farmland soil, removal efficiencies were 69.12, 78.30, and 39.50%, respectively. We then employed response surface methodology to optimize the washing parameters. The optimization process showed that the removal efficiencies were 69.50, 88.09, and 40.45% in mine soil and 71.34, 81.02, and 50.95% in polluted farmland soil for Cd, Pb, and Zn, respectively. Moreover, the overall highly effective removal of Cd and Pb was connected mainly to their highly effective removal from the water-soluble, exchangeable, and carbonate fractions. GLDA-washing eliminated the same amount of metals as EDTA-washing, while simultaneously retaining most of the soil nutrients. Removal efficiencies of recycled GLDA were no >5% lower than those of the fresh GLDA. Therefore, GLDA could potentially be used for the rehabilitation of soil contaminated by heavy metals. Copyright © 2016 Elsevier B.V. All rights reserved.

  3. Hair dyeing, hair washing and hair cortisol concentrations among women from the healthy start study

    DEFF Research Database (Denmark)

    Kristensen, Sheila K.; Larsen, Sofus C.; Olsen, Nanna J.

    2017-01-01

    Background: Hair cortisol concentration (HCC) has been suggested as a promising marker for chronic stress. However, studies investigating the influence of hair dyeing and hair washing frequency on HCC have shown inconsistent results. Objective: To examine associations between HCC and hair dyeing...... status or weekly hair washing frequency among women. Methods: This cross-sectional study was based on data from 266 mothers participating in the Healthy Start intervention study. HCC was measured in the proximal end of the hair (1–2 cm closest to the scalp) while hair dyeing status, frequency of hair...... washing and covariates were reported by the women. Linear regression analyses were applied to assess the associations between HCC and hair dyeing or weekly frequency of hair washing. Results: No statistically significant difference (p = 0.91) in HCC was found between women who dyed hair (adjusted mean...

  4. Effect of acid washing on pyrolysis of Cladophora socialis alga in microtubing reactor

    International Nuclear Information System (INIS)

    Ly, Hoang Vu; Kim, Seung-Soo; Kim, Jinsoo; Choi, Jae Hyung; Woo, Hee Chul

    2015-01-01

    Highlights: • Pyrolysis of macroalgae Cladophora socialis was conducted in micro tubular reactor. • Acid washing affected the pyrolysis behavior of Cladophora socialis. • Pyrolysis of raw and acid washed C. socialis produced bio-oils with different compositions. • Pyrolysis reaction pathway was from C. socialis to liquid and then to gas (C_1–C_4). - Abstract: Cladophora socialis is a unique macroalga that is widely grown in the coastal regions of Vietnam. In this work, the pyrolysis characteristics of C. socialis were evaluated using thermogravimetric analysis (TGA) and pyrolysis in a tubing reactor. Macroalgae have a high content of inorganic compounds. These compounds result in high char content during pyrolysis of the macroalgae, which degrades the quality of the product bio-oil. In order to study this effect, C. socialis was demineralized by acid washing to remove the inorganic compounds. The effect of acid washing on the pyrolysis product distribution and the selectivity of composition in pyrolysis oil was carefully investigated. The kinetic parameters and the primary reaction pathways were also determined based on experimental data using nonlinear least-squares regression assuming a first-order kinetics model.

  5. Mitigation of heavy metals in different vegetables through biological washing techniques

    Directory of Open Access Journals (Sweden)

    Muhammad Umair Sattar

    2015-12-01

    Full Text Available Availability of nutritious and healthy food is the foremost challenging issue in all over the word. Vegetables are essential part in human diet and considered as natural reserves of nutrients gifted by Almighty Allah to human beings. Heavy metals are among the most toxic food pollutants and their intake through diet leads to several disorders. The sources of heavy metal contamination include waste water irrigation, industrial emissions, transportation and application of metal-based pesticides. In Pakistan this situation is more alarming as vegetables grown in peri-urban areas have shown high incidence of heavy metals accumulation. In this study effort was made to mitigate different heavy metals (Ar, Cd, Cr and Pb in cauliflower, spinach, okra and brinjal collected from peri-urban areas through washing with different biological solutions. Heavy metals contents were determined by using Atomic Absorption Spectrophotometry (AAS. Vegetable showed high load of heavy metals in unwashed form that reduced significantly by washing with different biological solutions. Among the different biological solutions, washing of vegetables with 8% ginger solution was found to be more effective.

  6. Point-of-care washing of allogeneic red blood cells for the prevention of transfusion-related respiratory complications (WAR-PRC): a protocol for a multicenter randomised clinical trial in patients undergoing cardiac surgery.

    Science.gov (United States)

    Warner, Matthew A; Welsby, Ian J; Norris, Phillip J; Silliman, Christopher C; Armour, Sarah; Wittwer, Erica D; Santrach, Paula J; Meade, Laurie A; Liedl, Lavonne M; Nieuwenkamp, Chelsea M; Douthit, Brian; van Buskirk, Camille M; Schulte, Phillip J; Carter, Rickey E; Kor, Daryl J

    2017-08-18

    The transfusion-related respiratory complications, transfusion-related acute lung injury (TRALI) and transfusion-associated circulatory overload (TACO), are leading causes of transfusion-related morbidity and mortality. At present, there are no effective preventive strategies with red blood cell (RBC) transfusion. Although mechanisms remain incompletely defined, soluble biological response modifiers (BRMs) within the RBC storage solution may play an important role. Point-of-care (POC) washing of allogeneic RBCs may remove these BRMs, thereby mitigating their impact on post-transfusion respiratory complications. This is a multicenter randomised clinical trial of standard allogeneic versus washed allogeneic RBC transfusion for adult patients undergoing cardiac surgery testing the hypothesis that POC RBC washing is feasible, safe, and efficacious and will reduce recipient immune and physiologic responses associated with transfusion-related respiratory complications. Relevant clinical outcomes will also be assessed. This investigation will enrol 170 patients at two hospitals in the USA. Simon's two-stage design will be used to assess the feasibility of POC RBC washing. The primary safety outcomes will be assessed using Wilcoxon Rank-Sum tests for continuous variables and Pearson chi-square test for categorical variables. Standard mixed modelling practices will be employed to test for changes in biomarkers of lung injury following transfusion. Linear regression will assess relationships between randomised group and post-transfusion physiologic measures. Safety oversight will be conducted under the direction of an independent Data and Safety Monitoring Board (DSMB). Approval of the protocol was obtained by the DSMB as well as the institutional review boards at each institution prior to enrolling the first study participant. This study aims to provide important information regarding the feasibility of POC washing of allogeneic RBCs and its potential impact on ameliorating

  7. Evaluation of the effects of repeated hand washing, sunlight, smoke and dirt on the persistence of deltamethrin on insecticide-treated nets.

    Science.gov (United States)

    Kayedi, M H; Lines, J D; Haghdoost, A A; Vatandoost, M H; Rassi, Y; Khamisabady, K

    2008-08-01

    Field studies were carried out in Iran to evaluate the effect of various factors (washing, sun, smoke, dust and dirt) on the residual insecticidal activity of PermaNet (a brand of long-lasting insecticidal net), and on nets conventionally treated with deltamethrin (K-O Tab), using bioassay tests. Thirty-two nets were washed five or 15 times, and eight nets were not washed at all. Nets were washed vigorously in cold tap water (17 degrees C, pH 8.9) with a detergent. Hand rubbing continued for 3min. After washing, some nets were exposed to dense smoke from a dung-hay fire for 3min and were also left exposed to the dusty wind between washes. One group of nets was exposed to the sunlight for the full 3-d interval between washes; another was exposed to sunlight for just 3h after each wash; two other groups were kept in the shade. There was a significantly greater loss of activity in nets exposed to the sun throughout the 3-d interval between washes: that is, for a total of 15 to 45 d. However, short sunlight exposure (maximum 3h between washes) during drying did not have any effect. We did not find any significant effect of exposure to dirt, dust and smoke after washing. It is concluded that the effect of sun is much smaller than that of washing, and that drying nets for a few hours in the sun is not harmful.

  8. Hygienic status assessment of dish washing waters, utensils, hands ...

    African Journals Online (AJOL)

    Hygienic status assessment of dish washing waters, utensils, hands and pieces of money from street food processing sites in Ouagadougou (Burkina Faso). N Barro, AR Bello, A Savadogo, CAT Ouattara, AJ Iiboudo, AS Traoré ...

  9. In-well time-of-travel approach to evaluate optimal purge duration during low-flow sampling of monitoring wells

    Science.gov (United States)

    Harte, Philip T.

    2017-01-01

    A common assumption with groundwater sampling is that low (time until inflow from the high hydraulic conductivity part of the screened formation can travel vertically in the well to the pump intake. Therefore, the length of the time needed for adequate purging prior to sample collection (called optimal purge duration) is controlled by the in-well, vertical travel times. A preliminary, simple analytical model was used to provide information on the relation between purge duration and capture of formation water for different gross levels of heterogeneity (contrast between low and high hydraulic conductivity layers). The model was then used to compare these time–volume relations to purge data (pumping rates and drawdown) collected at several representative monitoring wells from multiple sites. Results showed that computation of time-dependent capture of formation water (as opposed to capture of preexisting screen water), which were based on vertical travel times in the well, compares favorably with the time required to achieve field parameter stabilization. If field parameter stabilization is an indicator of arrival time of formation water, which has been postulated, then in-well, vertical flow may be an important factor at wells where low-flow sampling is the sample method of choice.

  10. Solvent wash solution

    International Nuclear Information System (INIS)

    Neace, J.C.

    1986-01-01

    This patent describes a process for removing diluent degradation products from a solvent extraction solution comprising an admixture of an organic extractant for uranium and plutonium and a non-polar organic liquid diluent, which has been used to recover uranium and plutonium from spent nuclear fuel. Comprising combining a wash solution consisting of: (a) water; and (b) a positive amount up to about, an including, 50 volume percent of at least one highly-polar water-miscible organic solvent, based on the total volume of the water and the highly-polar organic solvent, with the solvent extraction solution after uranium and plutonium values have been stripped from the solvent extraction solution, the diluent degradation products dissolving in the highly-polar organic solvent and the extractant and diluent of the extraction solution not dissolving in the highly-polar organic solvent, and separating the highly-polar organic solvent and the extraction solution to obtain a purified extraction solution

  11. Weed seed spread and its prevention: The role of roadside wash down.

    Science.gov (United States)

    Bajwa, Ali Ahsan; Nguyen, Thi; Navie, Sheldon; O'Donnell, Chris; Adkins, Steve

    2018-02-15

    Vehicles are one of the major vectors of long-distance weed seed spread. Viable seed removed from vehicles at roadside wash down facilities was studied at five locations in central Queensland, Australia over a 3-year period. Seed from 145 plant species, belonging to 34 different families, were identified in the sludge samples obtained from the wet particulate matter collection pit of the wash down facilities. Most of the species were annual forbs (50%) with small or very small seed size (weed was observed in these samples. More parthenium weed seed were found in the Rolleston facility and in the spring, but its seed was present in all facilities and in all seasons. The average number of viable seed found within every ton of dry particulate matter removed from vehicles was ca. 68,000. Thus, a typical wash down facility was removing up to ca. 335,000 viable seed from vehicles per week, of which ca. 6700 were parthenium weed seed. Furthermore, 61% of these seed (ca. 200,000) were from introduced species, and about half of these (35% of total) were from species considered to be weeds. Therefore, the roadside wash down facilities found throughout Queensland can remove a substantial amount of viable weed seed from vehicles, including the invasive parthenium weed, and the use of such facilities should be strongly encouraged. Copyright © 2017 Elsevier Ltd. All rights reserved.

  12. Minimum Additive Waste Stabilization (MAWS), Phase I: Soil washing final report

    International Nuclear Information System (INIS)

    1995-08-01

    As a result of the U.S. Department of Energy's environmental restoration and technology development activities, GTS Duratek, Inc., and its subcontractors have demonstrated an integrated thermal waste treatment system at Fernald, OH, as part the Minimum Additive Waste Stabilization (MAWS) Program. Specifically, MAWS integrates soil washing, vitrification of mixed waste streams, and ion exchange to recycle and remediate process water to achieve, through a synergistic effect, a reduction in waste volume, increased waste loading, and production of a durable, leach-resistant, stable waste form suitable for disposal. This report summarizes the results of the demonstration/testing of the soil washing component of the MAWS system installed at Fernald (Plant 9). The soil washing system was designed to (1) process contaminated soil at a rate of 0.25 cubic yards per hour; (2) reduce overall waste volume and provide consistent-quality silica sand and contaminant concentrates as raw material for vitrification; and (3) release clean soil with uranium levels below 35 pCi/g. Volume reductions expected ranged from 50-80 percent; the actual volume reduction achieved during the demonstration reached 66.5 percent. The activity level of clean soil was reduced to as low as 6 pCi/g from an initial average soil activity level of 17.6 pCi/g (the highest initial level of soil provided for testing was 41 pCi/g). Although the throughput of the soil washing system was inconsistent throughout the testing period, the system was online for sufficient periods to conclude that a rate equivalent to 0.25 cubic yards per hour was achieved

  13. Work plan for ground water elevation data recorder/monitor well installation at Gunnison, Colorado. Revision 1

    International Nuclear Information System (INIS)

    1994-08-01

    The purpose of this document is to describe the work that will be performed and the procedures that will be followed during installation of ground water monitor wells and ground water elevation data recorders (data loggers) at the Gunnison, Colorado, Uranium Mill Tailings Remedial Action (UMTRA) Project site. The monitor wells and data loggers will be used to gather required time-dependent data to investigate the interaction between ground water and surface water in the area. Data collection objectives (DCO) identify reasons for collecting data. The following are DCOs for the Gunnison ground water elevation data recorder/monitor well installation project: long-term continuous ground water level data and periodic ground water samples will be collected to better understand the relationship between surface and ground water at the site; water level and water quality data will eventually be used in future ground water modeling to more firmly establish numerical model boundary conditions in the vicinity of the Gunnison processing site; and modeling results will be used to demonstrate and document the potential remedial alternative of natural flushing

  14. Recovery of MSWI and soil washing residues as concrete aggregates.

    Science.gov (United States)

    Sorlini, Sabrina; Abbà, Alessandro; Collivignarelli, Carlo

    2011-02-01

    The aim of the present work was to study if municipal solid waste incinerator (MSWI) residues and aggregates derived from contaminated soil washing could be used as alternative aggregates for concrete production. Initially, chemical, physical and geometric characteristics (according to UNI EN 12620) of municipal solid waste incineration bottom ashes and some contaminated soils were evaluated; moreover, the pollutants release was evaluated by means of leaching tests. The results showed that the reuse of pre-treated MSWI bottom ash and washed soil is possible, either from technical or environmental point of view, while it is not possible for the raw wastes. Then, the natural aggregate was partially and totally replaced with these recycled aggregates for the production of concrete mixtures that were characterized by conventional mechanical and leaching tests. Good results were obtained using the same dosage of a high resistance cement (42.5R calcareous Portland cement instead of 32.5R); the concrete mixture containing 400 kg/m(3) of washed bottom ash and high resistance cement was classified as structural concrete (C25/30 class). Regarding the pollutants leaching, all concrete mixtures respected the limit values according to the Italian regulation. Copyright © 2010 Elsevier Ltd. All rights reserved.

  15. Work plan for ground water elevation data recorder/monitor well installation at Grand Junction, Colorado. Revision 1

    International Nuclear Information System (INIS)

    1994-08-01

    The purpose of this document is to describe the work that will be performed and the procedures that will be followed during installation of ground water monitor wells and ground water elevation data recorders (data loggers) at the Grand Junction, Colorado, Uranium Mill Tailings Remedial Action (UMTRA) Project site. The monitor wells and data loggers will be used to gather required time-dependent data to investigate the interaction between the shallow aquifer and the Colorado River

  16. Effectiveness of Commercial and Homemade Washing Agents in Removing Pesticide Residues on and in Apples.

    Science.gov (United States)

    Yang, Tianxi; Doherty, Jeffery; Zhao, Bin; Kinchla, Amanda J; Clark, John M; He, Lili

    2017-11-08

    Removal of pesticide residues from fresh produce is important to reduce pesticide exposure to humans. This study investigated the effectiveness of commercial and homemade washing agents in the removal of surface and internalized pesticide residues from apples. Surface-enhanced Raman scattering (SERS) mapping and liquid chromatography tandem mass spectrometry (LC-MS/MS) methods were used to determine the effectiveness of different washing agents in removing pesticide residues. Surface pesticide residues were most effectively removed by sodium bicarbonate (baking soda, NaHCO 3 ) solution when compared to either tap water or Clorox bleach. Using a 10 mg/mL NaHCO 3 washing solution, it took 12 and 15 min to completely remove thiabendazole or phosmet surface residues, respectively, following a 24 h exposure to these pesticides, which were applied at a concentration of 125 ng/cm 2 . LC-MS/MS results showed, however, that 20% of applied thiabendazole and 4.4% of applied phosmet had penetrated into the apples following the 24 h exposure. Thiabendazole, a systemic pesticide, penetrated 4-fold deeper into the apple peel than did phosmet, a non-systemic pesticide, which led to more thiabendazole residues inside the apples, which could not be washed away using the NaHCO 3 washing solution. This study gives us the information that the standard postharvest washing method using Clorox bleach solution for 2 min is not an effective means to completely remove pesticide residues on the surface of apples. The NaHCO 3 method is more effective in removing surface pesticide residues on apples. In the presence of NaHCO 3 , thiabendazole and phosmet can degrade, which assists the physical removal force of washing. However, the NaHCO 3 method was not completely effective in removing residues that have penetrated into the apple peel. The overall effectiveness of the method to remove all pesticide residues diminished as pesticides penetrated deeper into the fruit. In practical application

  17. Optimizing the molarity of a EDTA washing solution for saturated-soil remediation of trace metal contaminated soils

    International Nuclear Information System (INIS)

    Andrade, M.D.; Prasher, S.O.; Hendershot, W.H.

    2007-01-01

    Three experiments were conducted to optimize the use of ethylenediaminetetraacetic acid (EDTA) for reclaiming urban soils contaminated with trace metals. As compared to Na 2 EDTA (NH 4 ) 2 EDTA extracted 60% more Zn and equivalent amounts of Cd, Cu and Pb from a sandy loam. When successively saturating and draining loamy sand columns during a washing cycle, which submerged it once with a (NH 4 ) 2 EDTA wash and four times with deionised water, the post-wash rinses largely contributed to the total cumulative extraction of Cd, Co, Cr, Cu, Mn, Ni, Pb and Zn. Both the washing solution and the deionised water rinses were added in a 2:5 liquid to soil (L:S) weight ratio. For equal amounts of EDTA, concentrating the washing solution and applying it and the ensuing rinses in a smaller 1:5 L:S weight ratio, instead of a 2:5 L:S weight ratio, increased the extraction of targeted Cr, Cu, Ni, Pb and Zn. - A single EDTA addition is best utilised in a highly concentrated washing solution given in a small liquid to soil weight ratio

  18. All You Have to Do is Wash Your Hands

    Centers for Disease Control (CDC) Podcasts

    2009-03-26

    This CDC Kidtastics podcast teaches children how and when to wash their hands properly.  Created: 3/26/2009 by National Center for Zoonotic, Vector-Borne, and Enteric Diseases (NCZVED).   Date Released: 3/26/2009.

  19. FOCUS ON HAND WASHING Yakubu Tahir Maigari Departm

    African Journals Online (AJOL)

    HP

    2014-10-24

    Oct 24, 2014 ... Management and Social Sciences, Federal University Kashere,. Gombe State ... Peace can also be maintained with fellow human beings through ... talent and skill to build a mighty ship with which he and his people took .... One important aspect of Islamic rituals where washing of hands is prominent is ...

  20. Removal of arsenic from Janghang smelter site and energy crops-grown soil with soil washing using magnetic iron oxide

    Science.gov (United States)

    Han, Jaemaro; Zhao, Xin; Lee, Jong Keun; Kim, Jae Young

    2014-05-01

    Arsenic compounds are considered carcinogen and easily enter drinking water supplies with their natural abundance. US Environmental Protection Agency is finalizing a regulation to reduce the public health risks from arsenic in drinking water by revising the current drinking water standard for arsenic from 50 ppb to 10 ppb in 2001 (USEPA, 2001). Therefore, soil remediation is also growing field to prevent contamination of groundwater as well as crop cultivation. Soil washing is adjusted as ex-situ soil remediation technique which reduces volume of the contaminated soil. The technique is composed of physical separation and chemical extraction to extract target metal contamination in the soil. Chemical extraction methods have been developed solubilizing contaminants containing reagents such as acids or chelating agents. And acid extraction is proven as the most commonly used technology to treat heavy metals in soil, sediment, and sludge (FRTR, 2007). Due to the unique physical and chemical properties, magnetic iron oxide have been used in diverse areas including information technology and biomedicine. Magnetic iron oxides also can be used as adsorbent to heavy metal enhancing removal efficiency of arsenic concentration. In this study, magnetite is used as the washing agent with acid extraction condition so that the injected oxide can be separated by magnetic field. Soil samples were collected from three separate areas in the Janghang smelter site and energy crops-grown soil to have synergy effect with phytoremediation. Each sample was air-dried and sieved (2mm). Soil washing condition was adjusted on pH in the range of 0-12 with hydrogen chloride and sodium hydroxide. After performing soil washing procedure, arsenic-extracted samples were analyzed for arsenic concentration by inductively coupled plasma optical emission spectrometer (ICP-OES). All the soils have exceeded worrisome level of soil contamination for region 1 (25mg/kg) so the soil remediation techniques are

  1. Leakage detection of Marcellus Shale natural gas at an Upper Devonian gas monitoring well: a 3-d numerical modeling approach.

    Science.gov (United States)

    Zhang, Liwei; Anderson, Nicole; Dilmore, Robert; Soeder, Daniel J; Bromhal, Grant

    2014-09-16

    Potential natural gas leakage into shallow, overlying formations and aquifers from Marcellus Shale gas drilling operations is a public concern. However, before natural gas could reach underground sources of drinking water (USDW), it must pass through several geologic formations. Tracer and pressure monitoring in formations overlying the Marcellus could help detect natural gas leakage at hydraulic fracturing sites before it reaches USDW. In this study, a numerical simulation code (TOUGH 2) was used to investigate the potential for detecting leaking natural gas in such an overlying geologic formation. The modeled zone was based on a gas field in Greene County, Pennsylvania, undergoing production activities. The model assumed, hypothetically, that methane (CH4), the primary component of natural gas, with some tracer, was leaking around an existing well between the Marcellus Shale and the shallower and lower-pressure Bradford Formation. The leaky well was located 170 m away from a monitoring well, in the Bradford Formation. A simulation study was performed to determine how quickly the tracer monitoring could detect a leak of a known size. Using some typical parameters for the Bradford Formation, model results showed that a detectable tracer volume fraction of 2.0 × 10(-15) would be noted at the monitoring well in 9.8 years. The most rapid detection of tracer for the leak rates simulated was 81 days, but this scenario required that the leakage release point was at the same depth as the perforation zone of the monitoring well and the zones above and below the perforation zone had low permeability, which created a preferred tracer migration pathway along the perforation zone. Sensitivity analysis indicated that the time needed to detect CH4 leakage at the monitoring well was very sensitive to changes in the thickness of the high-permeability zone, CH4 leaking rate, and production rate of the monitoring well.

  2. The impact of aqueous washing on the ability of βFeOOH to corrode iron.

    Science.gov (United States)

    Watkinson, D E; Emmerson, N J

    2017-01-01

    Controlling the corrosion of historical and archaeological ferrous metal objects presents a significant challenge to conservators. Chloride is a major corrosion accelerator in coastal areas for historic ferrous metal structures and for the many chloride-containing archaeological objects within museums. Corrosion reactions involve the formation of akaganéite (βFeOOH) which incorporates chloride within its crystal structure and adsorbs it onto its surface. The mobility of the surface-adsorbed chloride in aqueous systems and atmospheric moisture means βFeOOH can itself cause iron to corrode. The extraction of chloride from βFeOOH by aqueous Soxhlet hot wash and aqueous room temperature washing is measured. The impact of this washing on the ability of βFeOOH to corrode iron is quantitatively investigated by determining the oxygen consumption of unwashed, Soxhlet-washed and room temperature-washed samples of βFeOOH mixed with iron powder and exposed to 80 % relative humidity. This acts as a proxy measurement for the corrosion rate of iron. The results are discussed relative to climatic factors for outdoor heritage objects and the treatment of archaeological iron in museums. Delivering better understanding of the properties of βFeOOH supports the development of evidence-based treatments and management procedures in heritage conservation.

  3. Effect of curd washing on the properties of reduced-calcium and standard-calcium Cheddar cheese.

    Science.gov (United States)

    Hou, Jia; McSweeney, Paul L H; Beresford, Thomas P; Guinee, Timothy P

    2014-10-01

    Washed (W) and nonwashed (NW) variants of standard (SCa) and reduced-calcium (RCa) Cheddar cheeses were made in triplicate, ripened for a 270-d period, and analyzed for composition and changes during maturation. Curd washing was applied to cheeses to give a target level of lactose plus lactic acid in cheese moisture of 3.9 g/100 g in the W cheese, compared with a value of 5.3 g/100 g of lactose plus lactic acid in cheese moisture in the control NW cheeses. The 4 cheese types were denoted standard calcium nonwashed (SCaNW), standard calcium washed (SCaW), reduced-calcium nonwashed (RCaNW), and reduced-calcium washed (RCaW). The mean calcium level was 760 mg/100 g in the SCaNW and SCaW and 660 mg/100 g in the RCaNW and RCaW cheeses. Otherwise the gross composition of all cheeses was similar, each with protein, fat, and moisture levels of ~26, 32, and 36 g/100 g, respectively. Curd washing significantly reduced the mean level of lactic acid in the SCaW cheese and residual lactose in both SCaW and RCaW cheeses. The mean pH of the standard-calcium cheese over the 270-d ripening period increased significantly with curd washing and ripening time, in contrast to the reduced-calcium cheese, which was not affected by the latter parameters. Otherwise curd washing had little effect on changes in populations of starter bacteria or nonstarter lactic acid bacteria, proteolysis, rheology, or color of the cheese during ripening. Descriptive sensory analysis at 270 d indicated that the SCaW cheese had a nuttier, sweeter, less fruity, and less rancid taste than the corresponding SCaNW cheese. In contrast, curd washing was not as effective in discriminating between the RCaW and RCaNW cheeses. The RCaW cheese had a more buttery, caramel odor and flavor, and a more bitter, less sweet, and nutty taste than the SCaW cheese, whereas the RCaNW had a more pungent and less fruity flavor, a less fruity odor, a saltier, more-bitter, and less acidic taste, and a more astringent mouthfeel than

  4. Effect of diluent wash over the removal of aqueous dissolved TBP and DBP in reprocessing

    International Nuclear Information System (INIS)

    Manjula, R.; Dasi, Mahesh; Mohandas, Jaya; Vijaya Kumar, N.; Kumar, T.

    2015-01-01

    In reprocessing of nuclear spent fuels by PUREX process Tri-n-Butyl phosphate diluted with n-Dodecane (nDD) is used as solvent. This solvent undergoes degradation due to radiation yielding degradation products, mainly Di-n-butyl phosphate (HDBP). During extraction steps some amount of these organic gets dissolved in aqueous phase owing to its mutual solubility. Removal of dissolved organic from aqueous streams before evaporation is essential to prevent red oil related disasters. Diluent wash technique employing nDD as diluent is one of the commonly used method for the same. During the continuous operation of this process, the diluent will get loaded with dissolved organic and subsequently the performance of diluent will not remain same as pure diluent. While some reports are available in literature for the efficiency of removal of TBP by nDD, so far no work has been reported for the removal of DBP. The scope of the present work is to ascertain the efficiency of diluent wash technique on the removal of dissolved TBP as well as DBP. The results obtained indicate that the removal of dissolved TBP by nDD decreases with increase in percentage of TBP in nDD. In the case of DBP it is just reverse and the removal becomes more effective when the TBP percentage in the diluent increases. A/O ratio of 6:1 is found to be more suitable. As the DBP is getting extracted very effectively into nDD containing TBP, diluent wash solution should be treated as spent organic and managed accordingly for further utilization

  5. Polyester Textiles as a Source of Microplastics from Households: A Mechanistic Study to Understand Microfiber Release During Washing.

    Science.gov (United States)

    Hernandez, Edgar; Nowack, Bernd; Mitrano, Denise M

    2017-06-20

    Microplastic fibers make up a large proportion of microplastics found in the environment, especially in urban areas. There is good reason to consider synthetic textiles a major source of microplastic fibers, and it will not diminish since the use of synthetic fabrics, especially polyester, continues to increase. In this study we provide quantitative data regarding the size and mass of microplastic fibers released from synthetic (polyester) textiles during simulated home washing under controlled laboratory conditions. Consideration of fabric structure and washing conditions (use of detergents, temperature, wash duration, and sequential washings) allowed us to study the propensity of fiber shedding in a mechanistic way. Thousands of individual fibers were measured (number, length) from each wash solution to provide a robust data set on which to draw conclusions. Among all the variables tested, the use of detergent appeared to affect the total mass of fibers released the most, yet the detergent composition (liquid or powder) or overdosing of detergent did not significantly influence microplastic release. Despite different release quantities due to the addition of a surfactant (approximately 0.025 and 0.1 mg fibers/g textile washed, without and with detergent, respectively), the overall microplastic fiber length profile remained similar regardless of wash condition or fabric structure, with the vast majority of fibers ranging between 100 and 800 μm in length irrespective of wash cycle number. This indicates that the fiber staple length and/or debris encapsulated inside the fabric from the yarn spinning could be directly responsible for releasing stray fibers. This study serves as a first look toward understanding the physical properties of the textile itself to better understand the mechanisms of fiber shedding in the context of microplastic fiber release into laundry wash water.

  6. Understanding transport pathways in a river system - Monitoring sediments contaminated by an incident

    Science.gov (United States)

    Dietrich, S.; Kleisinger, C.; Hillebrand, G.; Claus, E.; Schwartz, R.; Carls, I.; Winterscheid, A.; Schubert, B.

    2016-12-01

    Experiments to trace transport of sediments and suspended particulate matter on a river scale are an expensive and difficult venture, since it causes a lot of official requirements. In spring 2015, polychlorinated biphenyls (PCB) were released during restoration works at a bridge in the upper part of the Elbe River, near the Czech-German border. In this study, the particle-bound PCB-transport is applied as a tracer for monitoring transport pathways of suspended solids (SS) along a whole river stretch over 700 km length. The incident was monitored by concentration measurements of seven indicator PCB congeners along the inland part of the Elbe River as well as in the Elbe estuary. Data from 15 monitoring stations (settling tanks) as well as from two longitudinal campaigns (grab samples) along the river in July and August 2015 are considered. The total PCB load is calculated for all stations on the basis of monthly contaminant concentrations and daily suspended sediment concentrations. Monte-Carlo simulations assess the uncertainties of the calculated load. 1D water levels and GIS analysis were used to locate temporal storage areas for the SS. It is shown that the ratio of high versus low chlorinated PCB congeners is a suitable tracer to distinguish the PCB load of the incident from the long-term background signal. Furthermore, the reduction of total PCB load within the upper Elbe indicates that roughly 24% of the SS were transported with the water by wash load. Approximately 600 km downstream of the incident site, the PCB-marked wash load was first identified in July 2015. PCB load transported intermittently in suspension was detected roughly 400 km downstream of the incident site by August 2015. In the Elbe Estuary, PCB-marked SS were only found upstream of the steep slope of water depth (approx. 4 to 15 m) within Hamburg harbor that acts as a major sediment sink. Here, SS from the inland Elbe are mixed with lowly contaminated marine material, which may mask the

  7. Comparison of methanol and isopropanol as wash solvents for determination of hair cortisol concentration in grizzly bears and polar bears.

    Science.gov (United States)

    Kroshko, Thomas; Kapronczai, Luciene; Cattet, Marc R L; Macbeth, Bryan J; Stenhouse, Gordon B; Obbard, Martyn E; Janz, David M

    2017-01-01

    Methodological differences among laboratories are recognized as significant sources of variation in quantification of hair cortisol concentration (HCC). An important step in processing hair, particularly when collected from wildlife, is the choice of solvent used to remove or "wash" external hair shaft cortisol prior to quantification of HCC. The present study systematically compared methanol and isopropanol as wash solvents for their efficiency at removing external cortisol without extracting internal hair shaft cortisol in samples collected from free-ranging grizzly bears and polar bears. Cortisol concentrations in solvents and hair were determined in each of one to eight washes of hair with each solvent independently. •There were no significant decreases in internal hair shaft cortisol among all eight washes for either solvent, although methanol removed detectable hair surface cortisol after one wash in grizzly bear hair whereas hair surface cortisol was detected in all eight isopropanol washes.•There were no significant differences in polar bear HCC washed one to eight times with either solvent, but grizzly bear HCC was significantly greater in hair washed with isopropanol compared to methanol.•There were significant differences in HCC quantified using different commercial ELISA kits commonly used for HCC determinations.

  8. Fenton oxidation treatment of spent wash-off liquor for reuse in reactive dying

    International Nuclear Information System (INIS)

    Mangat, A.; Shaikh, I.A.; Ahmed, F.; Baqar, M

    2014-01-01

    The use of clean and high quality water in textile dyeing process is very expensive. In this study, the potential of reusing Fenton treated wash-off wastewater generated at the end of reactive dyeing was investigated. The treated wastewater was used in several dyeings employing three widely used reactive dyes, C. I. Reactive Yellow 145, C. I. Reactive Red 194, and C. I. Reactive Blue 221. Experimental results showed that at acidic pH (3.5) using optimized quantities of FeSO/sub 4/ and H/sub 2/O/sub 2/, Fenton process yielded a significant reduction (80-99%) of colour and COD in 30 minutes of treatment time. New dyeings were then carried out in Fenton decolourized wash-off wastewater, and dyed fabric samples were subjected to quality evaluations in terms of wash fastness, crock fastness, and colour difference properties (delta L*, delta c*, delta h*, and delta E*). This study concluded that Fenton oxidation was an efficient method for the treatment of textile wash-off wastewater, and treated liquor can be effectively recycled in next dyeing, without compromising quality parameters. This method proved to be an eco-friendly process owing to the fact that it did not use any fresh water. (author)

  9. Four deaths due to carbon monoxide poisoning in car washes.

    Science.gov (United States)

    Carson, H J; Stephens, P J

    1999-09-01

    In a period of 13 months, three separate incidents of lethal carbon monoxide (CO) poisoning in closed car wash bays resulted in the deaths of 4 white men aged 20 to 36 years. Each man appears to have been intoxicated with mind-altering substances, which may impair judgment, perception of outside conditions, and self-awareness. All four died in winter months. For three men, the deaths were ruled accidental, and for the remaining man, the previous deaths appear to have provided a model for suicide. Warning signs may not be effective to prevent future CO deaths in car washes because of the possible role of intoxication. Mechanical or electronic methods to prevent a bay door from closing completely may be preferable.

  10. Electroless copper plating on 3-mercaptopropyltriethoxysilane modified PET fabric challenged by ultrasonic washing

    International Nuclear Information System (INIS)

    Lu Yinxiang

    2009-01-01

    Electroless deposition of Cu on poly(ethylene terephthalate) (PET) fabric modified with 3-mercaptopropyltriethoxysilane was investigated. Morphology, composition, structure, thermal decomposing behavior of copper coating PET fabric after ultrasonic washing in water for 1 h were characterized by scanning electron microscopy (SEM), energy dispersive X-ray (EDX) analysis, X-ray photoelectron spectroscopy (XPS), Raman spectrometer, X-ray diffraction (XRD), and thermogravimetric analysis (TG), respectively. Copper plating on modified fabric has good adherence stability and high electric conductivity before and after ultrasonic washing, while copper coating fabric without modification is easily destroyed during the washing process, which leads to the textile changing from conductor to dielectric. As the copper weight on the treated fabric is 28 g/m 2 , the shielding effectiveness (SE) is more than 54 dB at frequency ranging from 0.01 MHz to 18 GHz.

  11. A novel study on UV protection and antibacterial properties of washed denim garment

    Directory of Open Access Journals (Sweden)

    Pervez Md. Nahid

    2017-01-01

    Full Text Available On this planet, many investigations are applied to switch conventional chemical cloth techniques via eco-pleasant and economically attractive bioprocesses using enzymes. The present study offers an enzymatic washing system using enzyme (Cellzyme SPL H/C for boosting the ultraviolet and antimicrobial undertaking of denim garments. Experimental results showed that the 4.0% o.w.f enzyme awareness furnished a greater UPF than the other concentrations and before washed. Results divulge that enzyme (Cellzyme SPL H/C not handiest preserve the fabric surface from UV degradation but also performed extended degree of antibacterial endeavour in opposition to some species of bacteria that leading to act as a nice antibacterial agent on the denim materials. The enzyme washing healing diminished the skin hairiness and accelerated the skin evenness of the denim fibres as shown by means of SEM measurements.

  12. Effects of household washing on bacterial load and removal of Escherichia coli from lettuce and "ready-to-eat" salads.

    Science.gov (United States)

    Uhlig, Elisabeth; Olsson, Crister; He, Jiayi; Stark, Therese; Sadowska, Zuzanna; Molin, Göran; Ahrné, Siv; Alsanius, Beatrix; Håkansson, Åsa

    2017-11-01

    Customer demands for fresh salads are increasing, but leafy green vegetables have also been linked to food-borne illness due to pathogens such as Escherichia coli O157:H7. As a safety measure, consumers often wash leafy vegetables in water before consumption. In this study, we analyzed the efficiency of household washing to reduce the bacterial content. Romaine lettuce and ready-to-eat mixed salad were washed several times in flowing water at different rates and by immersing the leaves in water. Lettuce was also inoculated with E. coli before washing. Only washing in a high flow rate (8 L/min) resulted in statistically significant reductions ( p  < .05), "Total aerobic count" was reduced by 80%, and Enterobacteriaceae count was reduced by 68% after the first rinse. The number of contaminating E. coli was not significantly reduced. The dominating part of the culturable microbiota of the washed lettuce was identified by rRNA 16S sequencing of randomly picked colonies. The majority belonged to Pseudomonadaceae , but isolates from Enterobacteriaceae and Staphylococcaceaceae were also frequently found. This study shows the inefficiency of tap water washing methods available for the consumer when it comes to removal of bacteria from lettuce. Even after washing, the lettuce contained high levels of bacteria that in a high dose and under certain circumstances may constitute a health risk.

  13. Estimating an appropriate sampling frequency for monitoring ground water well contamination

    International Nuclear Information System (INIS)

    Tuckfield, R.C.

    1994-01-01

    Nearly 1,500 ground water wells at the Savannah River Site (SRS) are sampled quarterly to monitor contamination by radionuclides and other hazardous constituents from nearby waste sites. Some 10,000 water samples were collected in 1993 at a laboratory analysis cost of $10,000,000. No widely accepted statistical method has been developed, to date, for estimating a technically defensible ground water sampling frequency consistent and compliant with federal regulations. Such a method is presented here based on the concept of statistical independence among successively measured contaminant concentrations in time

  14. Hand washing practices amongst medical students in Port Harcourt ...

    African Journals Online (AJOL)

    Alasia Datonye

    Background: Hand washing with soap and water is one of ... Method: This was a descriptive cross sectional survey ... simple questionnaire exploring perceptions, attitudes and ... Many studies have shown that doctors decontaminating their hands between seeing patients ..... countries: a systematic review and meta analysis.

  15. Physical separations soil washing system cold test results

    Energy Technology Data Exchange (ETDEWEB)

    McGuire, J.P.

    1993-07-28

    This test summary describes the objectives, methodology, and results of a physical separations soil-washing system setup and shakedown test using uncontaminated soil. The test is being conducted in preparation for a treatability test to be conducted in the North Pond of the 300-FF-1 Operable Unit. It will be used to assess the feasibility of using a physical separations process to reduce the volume of contaminated soils in the 300-FF-1 Operable Unit. The test is described in DOE-RL (1993). The setup test was conducted at an uncontrolled area located approximately 3.2 km northwest of the 300-FF-1 Operable Unit. The material processed was free of contamination. The physical separation equipment to be used in the test was transferred to the US Department of Energy (DOE) by the US Environmental Protection Agency (EPA) Risk Reduction Engineering Laboratory. On May 13, 1993, soil-washing equipment was moved to the cold test location. Design assistance and recommendation for operation was provided by the EPA.

  16. A Study on the Removal of Cesium in Soil Contaminated with Radiation Using a Soil Washing Process

    International Nuclear Information System (INIS)

    Park, Ukryang; Kim, Gyenam; Kim, Seungsoo; Park, Hyemin; Kim, Wansuk; Moon, Jaikwon

    2013-01-01

    The first principle is related with the washing process which is carried out to transfer the contaminated mass from the soil to water by dissolving it with a cleansing solution. The second is concerned with the size of the separation process which focuses on the reduction of the volume by separating the subject matters based on the different sizes of the soil. The complex agents used in the soil washing process include HCl, Oxalic acid, Citric acid, CaCl 2 , BaCl 2 , NH 4 NO 3 , and NaOH. It is known that the complex-forming capacity of such complex agents and radionuclides influences the decontamination from the soil. Also, since the forms of the chemical species related with the complex agents and the surface potential of the soil vary based on the changes of acidity observed in the cleansing solution, the level of acidity in the cleansing solution can be regarded as a factor that influences the decontamination. Therefore, in this study, H 2 SO 4 was selected as the complex agent and used to check the influence of the temperature when the subject contaminated soil was washed. Then, by applying the sieve grading process with a sieve-shaker, the size separation process was carried out to measure the level of radiation for each size. By washing the contaminated soil separated into different sizes with the complex agent H 2 SO 4 , the different removal tendencies for each size were considered. After selecting the complex agent H 2 SO 4 and checking the influence of temperature when the contaminated soil was washed based on the solid-liquid ratio of 1g:2ml, it was found that the heat washing process at a temperature of 95 .deg. C showed a higher level of efficiency for the removal of Cs compared to the case of the non-heat washing process. Also, according to the results given by the process of considering the different removal tendencies for each size based on the heat washing process after the sieve grading process was applied with the sieve-shaker prior for the size

  17. Effect of preputial washing on bacterial load and preservability of semen in Murrah buffalo bulls

    Directory of Open Access Journals (Sweden)

    G. S. Meena

    2015-06-01

    Full Text Available Aim: To study the effect of preputial washing on bacterial load, preservability and semen quality in Murrah buffalo bulls Materials and Methods: A total of 36 collections of three Murrah buffalo bulls maintained at Artificial Breeding Research Centre, ICAR-National Dairy Research Institute, Karnal, were collected at weekly intervals from each bull without preputial washing and latter ejaculates from same bull with preputial washing by infusing normal saline (0.85%, KMnO4 (0.02% and savlon (2.0% to first, second and third bull, respectively. The microbial load and semen quality were evaluated during different hours of storage at refrigerated temperature (0, 24 and 48 h and after thrawing of cryopreserved (at −196°C semen. Results: The results of preservation of semen at refrigerated temperature showed that bacterial load was markedly lower in ejaculates of bulls subjected to preputial washing. Semen preserved at refrigerator temperature and cryopreserved, the effect of washing solution was significant for individual motility (IM, non-eosiniphilic count, hypo-osmotic swelling reactivity (HOST, total plate count (TPC and acrosome integrity. KMnO4 was found to be the best in lowering bacterial load, sperm abnormalities and in improving semen quality such as motility, non-eosinophilic count, HOST and acrosome integrity even up to 48 h of preservation and cryopreserved semen. Effect of duration of preservation and stage of cryopreservation was also significant for IM, non-eosiniphilic count, HOST, sperm abnormalities and acrosome integrity. Conclusion: Overall the results suggested that preputial washing with KMnO4 solution improved the semen quality and reduced microbial load of Murrah buffalo bull’s semen preserved at refrigerated temperature and cryopreservation.

  18. Candida and Fusarium species known as opportunistic human pathogens from customer-accessible parts of residential washing machines.

    Science.gov (United States)

    Babič, Monika Novak; Zalar, Polona; Ženko, Bernard; Schroers, Hans-Josef; Džeroski, Sašo; Gunde-Cimerman, Nina

    2015-03-01

    Energy constraints have altered consumer practice regarding the use of household washing machines. Washing machines were developed that use lower washing temperatures, smaller amounts of water and biodegradable detergents. These conditions may favour the enrichment of opportunistic human pathogenic fungi. We focused on the isolation of fungi from two user-accessible parts of washing machines that often contain microbial biofilms: drawers for detergents and rubber door seals. Out of 70 residential washing machines sampled in Slovenia, 79% were positive for fungi. In total, 72 strains belonging to 12 genera and 26 species were isolated. Among these, members of the Fusarium oxysporum and Fusarium solani species complexes, Candida parapsilosis and Exophiala phaeomuriformis represented 44% of fungi detected. These species are known as opportunistic human pathogens and can cause skin, nail or eye infections also in healthy humans. A machine learning analysis revealed that presence of detergents and softeners followed by washing temperature, represent most critical factors for fungal colonization. Three washing machines with persisting malodour that resulted in bad smelling laundry were analysed for the presence of fungi and bacteria. In these cases, fungi were isolated in low numbers (7.5 %), while bacteria Micrococcus luteus, Pseudomonas aeruginosa, and Sphingomonas species prevailed. Copyright © 2014 The British Mycological Society. Published by Elsevier Ltd. All rights reserved.

  19. Personalized Health Monitoring System for Managing Well-Being in Rural Areas.

    Science.gov (United States)

    Nedungadi, Prema; Jayakumar, Akshay; Raman, Raghu

    2017-12-14

    Rural India lacks easy access to health practitioners and medical centers, depending instead on community health workers. In these areas, common ailments that are easy to manage with medicines, often lead to medical escalations and even fatalities due to lack of awareness and delayed diagnosis. The introduction of wearable health devices has made it easier to monitor health conditions and to connect doctors and patients in urban areas. However, existing initiatives have not succeeded in providing adequate health monitoring to rural and low-literate patients, as current methods are expensive, require consistent connectivity and expect literate users. Our design considerations address these concerns by providing low-cost medical devices connected to a low-cost health platform, along with personalized guidance based on patient physiological parameters in local languages, and alerts to medical practitioners in case of emergencies. This patient-centric integrated healthcare system is designed to manage the overall health of villagers with real-time health monitoring of patients, to offer guidance on preventive care, and to increase health awareness and self-monitoring at an affordable price. This personalized health monitoring system addresses the health-related needs in remote and rural areas by (1) empowering health workers in monitoring of basic health conditions for rural patients in order to prevent escalations, (2) personalized feedback regarding nutrition, exercise, diet, preventive Ayurveda care and yoga postures based on vital parameters and (3) reporting of patient data to the patient's health center with emergency alerts to doctor and patient. The system supports community health workers in the diagnostic procedure, management, and reporting of rural patients, and functions well even with only intermittent access to Internet.

  20. Residues of maneb in potatoes and lettuce and their persistence during cooking, washing and uv exposition

    International Nuclear Information System (INIS)

    Bennaceur, M.; Sennaoui, Z.; Zennouche, B.; Hylin, J.W.

    1992-01-01

    Lettuce plants were treated each with 0,186 mg of 14C maneb and 1,86 mg unlabelled maneb. The plants were analyzed 30 days later and subjected to washing. Washing eliminates 17,46% of total 14C maneb applied. No Etu was observed in water.Washing and baking cause a significant decrease of EBDC in potatoes samples and the UV exposition involves a decrease of the fungicide and a formation of Etu. On the other hand 54 % and 38% of lettuce and potatoe samples analyzed by CS2 method exceed the authorized norms

  1. Design and Construction of a Computer Controlled Clothes Washing ...

    African Journals Online (AJOL)

    MICHAEL

    The search for easier and highly efficient ways of washing clothes ... This would help to reduce the running cost. .... It was only necessary to connect to the 8 data lines and the ... is actually a step further into complete automation of the clothes ...

  2. Preliminary gravity and magnetic models across Midway Valley and Yucca Wash, Yucca Mountain, Nevada

    International Nuclear Information System (INIS)

    Ponce, D.A.; Langenheim, V.E.

    1994-01-01

    Detailed gravity and ground magnetic data collected along ten traverses across Midway Valley and Yucca Wash on the eastern flank of Yucca Mountain in southwest Nevada are interpreted. These data were collected as part of an effort to evaluate faulting in the vicinity of proposed surface facilities for a potential nuclear waste repository at Yucca Mountain. Geophysical data show that Midway Valley is bounded by large gravity and magnetic anomalies associated with the Bow Ridge and Paintbrush Canyon faults, on the west side of Exile Hill and on the west flank of Fran Ridge, respectively. In addition, Midway Valley itself is characterized by a number of small-amplitude anomalies that probably reflect small-scale faulting beneath Midway Valley. Gravity and magnetic data across the northwest trending Yucca Wash and the inferred Yucca Wash fault indicate no major vertical offsets greater than 100 m using a density contrast of 0.2 to 0.3 g/cm 3 along the proposed Yucca Wash fault. In addition, a broad magnetic high coincides with the approximate location of the hydrologic gradient and probably reflects moderately magnetic Topopah Spring Tuff or lavas in the Calico Hills Formation

  3. Anaerobic treatment of distillery spent wash - a study on upflow anaerobic fixed film bioreactor.

    Science.gov (United States)

    Acharya, Bhavik K; Mohana, Sarayu; Madamwar, Datta

    2008-07-01

    Anaerobic digestion of wastewater from a distillery industry having very high COD (1,10,000-1,90,000 mg/L) and BOD (50,000-60,000 mg/L) was studied in a continuously fed, up flow fixed film column reactor using different support materials such as charcoal, coconut coir and nylon fibers under varying hydraulic retention time and organic loading rates. The seed consortium was prepared by enrichment with distillery spent wash in a conventional type reactor having working capacity of 3 L and was used for charging the anaerobic column reactor. Amongst the various support materials studied the reactor having coconut coir could treat distillery spent wash at 8d hydraulic retention time with organic loading rate of 23.25 kg COD m(-3)d(-1) leading to 64% COD reduction with biogas production of 7.2 m3 m(-3)d(-1) having high methane yield without any pretreatment or neutralization of the distillery spent wash. This study indicates fixed film biomethanation of distillery spent wash using coconut coir as the support material appears to be a cost effective and promising technology for mitigating the problems caused by distillery effluent.

  4. Removal of oxyfluorfen from ex-situ soil washing fluids using electrolysis with diamond anodes.

    Science.gov (United States)

    dos Santos, Elisama Vieira; Sáez, Cristina; Martínez-Huitle, Carlos Alberto; Cañizares, Pablo; Rodrigo, Manuel Andres

    2016-04-15

    In this research, firstly, the treatment of soil spiked with oxyfluorfen was studied using a surfactant-aided soil-washing (SASW) process. After that, the electrochemical treatment of the washing liquid using boron doped diamond (BDD) anodes was performed. Results clearly demonstrate that SASW is a very efficient approach in the treatment of soil, removing the pesticide completely by using dosages below 5 g of sodium dodecyl sulfate (SDS) per Kg of soil. After that, complete mineralization of organic matter (oxyflourfen, SDS and by-products) was attained (100% of total organic carbon and chemical oxygen demand removals) when the washing liquids were electrolyzed using BDD anodes, but the removal rate depends on the size of the particles in solution. Electrolysis of soil washing fluids occurs via the reduction in size of micelles until their complete depletion. Lower concentrations of intermediates are produced (sulfate, chlorine, 4-(trifluoromethyl)-phenol and ortho-nitrophenol) during BDD-electrolyzes. Finally, it is important to indicate that, sulfate (coming from SDS) and chlorine (coming from oxyfluorfen) ions play an important role during the electrochemical organic matter removal. Copyright © 2016 Elsevier Ltd. All rights reserved.

  5. Recovery And Valorization Of Snakehead Fish Channa Striata Surimi Wash Water As Stock Albumin Tablet

    Directory of Open Access Journals (Sweden)

    Ikbal Syukroni

    2017-11-01

    Full Text Available Surimi washing process is aimed to concentrate the myofibril protein by removing catepsin enzyme fat pigment blood and sarcoplasmic protein which is soluble in wash water. The soluble subtances cause trouble environment if it was untreated. In addition recovery protein will give benefit both in reducing trouble environment and utilizing soluble protein as sources of albumin protein. The objectives of research were to recover albumin from snakehead fish surimi wash water and to valorize as stock albumin tablet. Recovery of albumin use 0.05 m ultrafiltration membrane and the valorization of albumin tablets was by direct compression. The protein band with molecular weight of 67.741 kDa on the retentate was detected as albumin. Concentration of protein recover by ultrafiltration membrane increased 89.98 and the albumin content 3.50.4 gdl. Based on the result of chemical composition and microbiology analysis albumin of snakehead surimi wash water appropriate with Indonesia National Standard SNI quality requirement about snakehead fish albumin extract. The best formulation in the preparation of surimi wash water albumin tablet was by using corn starch excipients with uniformity weight value 410.39 0.09 g hardness value 7.65 0.8 Kp uniformity size of tablet with diameter 1 cm and thickness 0.59 cm friability value 2.3 and disintregation time of the tablet is 2 minutes 16 second.

  6. Water usage characteristics of car wash facilities in Ortahisar district of Trabzon province

    OpenAIRE

    Karabacak, Volkan; Topbaş, Murat; Karakullukçu, Serdar; Demirtaş, Yusuf; Çankaya, Sertaç; Çan, Gamze; Beyhun, N. Ercüment

    2018-01-01

    Introduction. Water management is ontop of the agenda for all countries Aimof the study. The aim of this study was to determine the water usage in thecar wash facilities of Ortahisar district of Trabzon province, such as thefeatures of the water used in drinking and car washing, the disposal ofwastewater and case of water interruption situation in the facilities. Material and methods. This descriptivestudy was conducted in Ortahisar district of Trabzon province. The studypopulation of the res...

  7. Development of technology for washed minced fish production from low-profit objects of fishing in the Volga-Caspian Basin

    Directory of Open Access Journals (Sweden)

    Mukatova M. D.

    2016-09-01

    Full Text Available The objects of the study are as follows: rudd and goldfish, samples of food minced made of them without washing, after single and double washings. To study the organoleptic and physico-chemical parameters the conventional methods of the fishing industry have been used. At the LLC "Astrakhan fisheries" two experimental batches of minced rudd and goldfish with double washing by water using a food additive "Omfresh plus" have been made in the amount of 1.0 % by weight of the meat. The yield of washed minced food from rudd is 41.4 %, from silver carp – 41.0 %. Some decrease in water content, water-holding capacity and formalin-titratable nitrogen in minced fish after each washing step has been established. Studying the organoleptic characteristics has shown that the frozen minced briquettes are cuboids, have clean surface with the presence of minor irregularities, colour – light gray, dense texture. On physical and chemical parameters the food washed mince correspond to GOST R 55505–2013 "Frozen food fish forcemeat. Specifications". Water content is 79–82 %, sodium chloride – 0,17–0,35 %, and water-holding capacity – at over 50 %. The proven technology of manufacturing washed minced from goldfish and rudd can be put into production for the purpose of deep processing of unprofitable species of the Volga-Caspian Basin and getting washed minced food and culinary products based on it.

  8. Results of calendar year 1994 monitor well inspection and maintenance program, Y-12 Plant, Oak Ridge, Tennessee

    International Nuclear Information System (INIS)

    McMaster, B.W.; Jones, S.B.; Sitzler, J.L.

    1995-06-01

    This document is a compendium of results of the calendar year 1994 Monitor Well Inspection and Maintenance Program at the Department of Energy Y-12 Plant in Oak Ridge, Tennessee. This report documents the work relating to well inspections and maintenance requests. Inspections are implemented in order to better assess the condition and maintenance needs of wells that are actively being monitored. Currently this approach calls for inspecting all wells on a routine (annual or triennial) basis which are: (1) in an active sampling program; (2) included in a hydrologic study; or (3) not in service, but not scheduled for plugging and abandonment. Routine inspections help to ensure that representative groundwater samples and hydrologic data are being collected, and contribute to the life expectancy of each well. This report formally presents well inspection and maintenance activities that were conducted at the Y-12 Plant during 1994. All inspections were conducted between April and December

  9. Results of calendar year 1994 monitor well inspection and maintenance program, Y-12 Plant, Oak Ridge, Tennessee

    Energy Technology Data Exchange (ETDEWEB)

    McMaster, B.W. [Univ. of Tennessee, Knoxville, TN (United States); Jones, S.B.; Sitzler, J.L. [Oak Ridge National Lab., TN (United States)

    1995-06-01

    This document is a compendium of results of the calendar year 1994 Monitor Well Inspection and Maintenance Program at the Department of Energy Y-12 Plant in Oak Ridge, Tennessee. This report documents the work relating to well inspections and maintenance requests. Inspections are implemented in order to better assess the condition and maintenance needs of wells that are actively being monitored. Currently this approach calls for inspecting all wells on a routine (annual or triennial) basis which are: (1) in an active sampling program; (2) included in a hydrologic study; or (3) not in service, but not scheduled for plugging and abandonment. Routine inspections help to ensure that representative groundwater samples and hydrologic data are being collected, and contribute to the life expectancy of each well. This report formally presents well inspection and maintenance activities that were conducted at the Y-12 Plant during 1994. All inspections were conducted between April and December.

  10. Recovery of silver from X-ray washings

    International Nuclear Information System (INIS)

    Begum, S.; Zeb, P.A.; Sharif, Q.

    2008-01-01

    This paper presents the enhanced recovery of silver from polymers and gelatin in X-ray washings by treating with activated carbon at different temperatures and optimizing the parameters as temperature, pH and acid base concentrations. It was found that at pilot scale silver recovery increased through treatment with activated carbon and in comparison to the temperature of 20 degree C, at 50 degree C, the recovery increased from 82.57% to 94.04%. (author)

  11. Hydrogen generation in SRAT with nitric acid and late washing flowsheets

    International Nuclear Information System (INIS)

    Hsu, C.W.

    1992-01-01

    Recently, SRTC recommended two process changes: (1) a final wash of the tetraphenylborate precipitate feed slurry and (2) the use of nitric acid to neutralize the sludge in the SRAT. The first change produced an aqueous hydrolysis product (PHA) with higher formic acid/formate and copper concentration, and reduced the nitrate content in the PHA by an order of magnitude. The second change is to substitute part of formic acid added to the SRAT with nitric acid, and therefore may reduce the hydrogen generated in the SRAT as well as provide nitrate as an oxidant to balance the redox state of the melter feed. The purpose of this report is to determine the pertinent variables that could affect the hydrogen generation rate with these process changes

  12. Soil remediation: humic acids as natural surfactants in the washings of highly contaminated soils

    International Nuclear Information System (INIS)

    Conte, Pellegrino; Agretto, Anna; Spaccini, Riccardo; Piccolo, Alessandro

    2005-01-01

    The remediation of the highly contaminated site around the former chemical plant of ACNA (near Savona) in Northern Italy is a top priority in Italy. The aim of the present work was to contribute in finding innovative and environmental-friendly technology to remediate soils from the ACNA contaminated site. Two soils sampled from the ACNA site (A and B), differing in texture and amount and type of organic contaminants, were subjected to soil washings by comparing the removal efficiency of water, two synthetic surfactants, sodium dodecylsulphate (SDS) and Triton X-100 (TX100), and a solution of a natural surfactant, a humic acid (HA) at its critical micelle concentration (CMC). The extraction of pollutants by sonication and soxhlet was conducted before and after the soil washings. Soil A was richer in polycyclic aromatic hydrocarbons, whereas soil B had a larger content of thiophenes. Sonication resulted more analytically efficient in the fine-textured soil B. The coarse-textured soil A was extracted with a general equal efficiency also by soxhlet. Clean-up by water was unable to exhaustively remove contaminants from the two soils, whereas all the organic surfactants revealed very similar efficiencies (up to 90%) in the removal of the contaminants from the soils. Hence, the use of solutions of natural HAs appears as a better choice for soil washings of highly polluted soils due to their additional capacity to promote microbial activity, in contrast to synthetic surfactants, for a further natural attenuation in washed soils. - Solutions of natural humic acids appear to be a better choice for washing highly polluted soils

  13. Removal of Uranium by Exchanger Resins from Soil Washing Solution

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Seung Soo; Han, G. S.; Kim, G. N.; Koo, D. S.; Jeong, J. W.; Moon, J. K. [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2015-05-15

    Uranyl ions in the acidic waste solution were sorbed on AM-resin resin with a high sorption efficiency, and desorbed from the resin by a batch-type washing with a 60 .deg. C heated 0.5 M Na{sub 2}CO{sub 3} solution. However, the uranium dissolved in the sulfuric acid solution was not sorbed onto the strong anion exchanger resins. Our group has developed a decontamination process with washing and electrokinetic methods for uranium-contaminated (U-contaminated) soil. However, this process generates a large amount of waste solution containing various metal ions. If the uranium selectively removed from the waste solution, a very small amount of the 2nd waste would be generated. Thus, selective sorption of uranium by ion exchange resins was examined in this study.

  14. Particle Separation of Non-Decontamination Soil using Attrition and Washing

    International Nuclear Information System (INIS)

    Koo, Daeseo; Sung, Hyun-Hee; Kim, Seung-Soo; Hong, Sang Bum; Seo, Bum Kyoung; Choi, Jong-Won

    2017-01-01

    In this study, to improve the decontamination efficiency of uranium soil, a preliminary experiment on the particle separation of non-decontamination soil was carried out using attrition and washing. The characteristics of the attrition and washing system are investigated. A conditional experiment on particle separation of non-decontamination soil will be performed. A preliminary experiment on the particle separation of non-decontamination soil was carried out to improve the decontamination efficiency of uranium soil. This experiment was performed with the ratio of soil to water (1:4) for the particle separation of non-decontamination soil. The operations of all equipment such as attrition scrubber, ultrasonic reaction, vibrating screen, and hydro-cyclone were conducted and confirmed. In the future, the additional experiments will be conducted for optimal experimental condition.

  15. Combining sieving and washing, a way to treat MSWI boiler fly ash.

    Science.gov (United States)

    De Boom, Aurore; Degrez, Marc

    2015-05-01

    Municipal Solid Waste Incineration (MSWI) fly ashes contain some compounds that could be extracted and valorised. A process based on wet sieving and washing steps has been developed aiming to reach this objective. Such unique combination in MSWI fly ash treatment led to a non-hazardous fraction from incineration fly ashes. More specifically, MSWI Boiler Fly Ash (BFA) was separately sampled and treated. The BFA finer particles (13wt%) were found to be more contaminated in Pb and Zn than the coarser fractions. After three washing steps, the coarser fractions presented leaching concentrations acceptable to landfill for non-hazardous materials so that an eventual subsequent valorisation may be foreseen. At the contrary, too much Pb leached from the finest particles and this fraction should be further treated. Wet sieving and washing permit thus to reduce the leachability of MSWI BFA and to concentrate the Pb and Zn contamination in a small (in particle size and volume) fraction. Such combination would therefore constitute a straightforward and efficient basis to valorise coarse particles from MSWI fly ashes. Copyright © 2015 Elsevier Ltd. All rights reserved.

  16. Selective Removal of Uranium from the Washing Solution of Uranium-Contaminated Soil

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Seung Soo; Han, G. S.; Kim, G. N.; Koo, D. S.; Jeong, J. W.; Choi, J. W. [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2015-10-15

    This study examined selective removal methods of uranium from the waste solution by ion exchange resins or solvent extraction methods to reduce amount of the 2{sup nd} waste. Alamine-336, known as an excellent extraction reagent of uranium from the leaching solution of uranium ore, did not remove uranium from the acidic washing solution of soil. Uranyl ions in the acidic waste solution were sorbed on ampholyte resin with a high sorption efficiency, and desorbed from the resin by a washing with 0.5 M Na{sub 2}CO{sub 3} solution at 60 .deg. C. However, the uranium dissolved in the sulfuric acid solution was not sorbed onto the strong anion exchanger resins. A great amount of uranium-contaminated (U-contaminated) soil had been generated from the decommissioning of a uranium conversion plant. Our group has developed a decontamination process with washing and electrokinetic methods to decrease the amount of waste to be disposed of. However, this process generates a large amount of waste solution containing various metal ions.

  17. Hydrodynamic calculation of a filter washing in liquids type used in containment venting systems

    International Nuclear Information System (INIS)

    Reyes G, A. A.; Sainz M, E.; Ortiz V, J.

    2015-09-01

    From the nuclear accident of Chernobyl, the European nuclear power plants have chosen to install filters on the venting pipes of the containment, whose function is to help to mitigate the consequences of a severe accident, by controlled depressurization of the containment passively through a filtered venting of the containment system. These systems are designed to relieve the internal pressure of the containment by means of the deliberate opening of pressure relief devices, either a valve or rupture disc during a severe accident and be channeled to the filter unit. In this paper the hydraulic response of a filter system of gases washing by liquid is evaluated, due to this information is necessary to estimate the effect that has the pressure increase of the contention on the discharge capacity of the venting pipes. By simulation of computational of fluid dynamics with the programs: CAELINUX-2014 and OpenFOAM, the hydrodynamic characteristics of the Multi Venturi System for gases washing from the containment, which could be included in the general model of the venting pipe, were obtained. Representative models of the Venturi tubes of each concentric area that forming the washing system were generated; and using parametric calculations the average mass flow rate established through each venturi, depending on its size and depth in which it is located inside the tank was estimated. Also, the pressure and mass flow rate required to activate each concentric area depending on the pressure and mass load from the containment were calculated, to estimate the maximum flow that is established through the filter. Finally, the velocity profiles and the characteristic pressure at which each area operates as well as the pressure drop of local and global discharge also were calculated. (Author)

  18. Selected Hydrologic Data for Sand Cove Wash, Washington County, Utah

    National Research Council Canada - National Science Library

    Norton, Aaron; Susong, David D

    2004-01-01

    .... Hydrologic data collected in this study are described and listed in this report. Six boreholes were drilled in Sand Cove Wash to determine the vertical and spatial distribution of the alluvial deposits and their hydrologic...

  19. Tailoring Water, Sanitation, and Hygiene (WASH) Targets for Soil-Transmitted Helminthiasis and Schistosomiasis Control.

    Science.gov (United States)

    Campbell, Suzy J; Biritwum, Nana-Kwadwo; Woods, Geordie; Velleman, Yael; Fleming, Fiona; Stothard, J Russell

    2018-01-01

    The World Health Organization's (WHO) 2015-2020 Global Strategy on water, sanitation, and hygiene (WASH) and neglected tropical diseases (NTDs) encourages integration, whilst maintaining existing structured NTD investments, and acceleration towards Sustainable Development Goal (SDG) targets. Accordingly, SDG-associated and WASH-NTD indicators have been developed, commencing important intersectoral dialogue, alongside opportunities for future disease-specific refinements. The rationale for soil-transmitted helminthiasis (STH)- and schistosomiasis-specific WASH considerations, and a traffic-light figure, are presented here to indicate where current international definitions may, or may not, suffice. Certain unique aspects in control dynamics and parasitic lifecycles, however, necessitate additional implementation research with more appropriate measurement indicators developed to record programmatic interventions and to define strategic priorities more effectively. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  20. Disinfection potential of ozone, ultraviolet-C and their combination in wash water for the fresh-cut vegetable industry.

    Science.gov (United States)

    Selma, María V; Allende, Ana; López-Gálvez, Francisco; Conesa, María A; Gil, María I

    2008-09-01

    The purpose of this research was to investigate the disinfection efficacy of ozone (O(3)) and UV-C illumination (UV), and their combination (O(3)-UV) for reducing microbial flora of fresh-cut onion, escarole, carrot, and spinach wash waters collected from the industry. Furthermore, the influence of water physicochemical parameters on the decontamination efficacy and the effect of these technologies on physicochemical quality of wash water were analyzed. O(3), UV, and O(3)-UV were effective disinfection treatments on vegetable wash water, with a maximum microbial reduction of 6.6 log CFU mL(-1) after 60 min treatment with O(3)-UV. However, maximum total microbial reductions achieved by UV and O(3) treatments after 60 min were 4.0 and 5.9 log CFU mL(-1), lower than by O(3)-UV treatment. Furthermore, turbidity of wash water was reduced significantly by O(3) and O(3)-UV treatments, while UV treatment did not affect the physicochemical quality of the water. Conclusions derived from this study illustrate that O(3) and O(3)-UV are alternatives to other sanitizers used in the fresh-cut washing processes. The use of these technologies would allow less frequent changing of spent water and the use of much lower sanitizer doses. Nevertheless, in specific applications such as carrot wash water, where levels of undesirable microbial and chemical constituents are lower than other vegetable wash water, UV treatment could be an appropriate treatment considering cost-effectiveness criteria.

  1. Work plan for ground water elevation data recorder/monitor well installation at the New Rifle Site, Rifle, Colorado

    International Nuclear Information System (INIS)

    1994-01-01

    The purpose of this document is to describe the work that will be performed and the procedures that will be followed during installation of ground water monitor wells and ground water elevation data recorders (data loggers) at the New Rifle Uranium Mill Tailings Remedial Action (UMTRA) Project site, Rifle, Colorado. The monitor wells and data loggers will be used to gather required time-dependent data to investigate the interaction between the shallow aquifer and the Colorado River

  2. Monitoring and optimization of thermal recovery wells at Nexen's Long Lake project

    Energy Technology Data Exchange (ETDEWEB)

    Furtado, S.; Howe, A.; Wozney, G.; Zaffar, S. [Nexen Inc. (Canada); Nelson, A. [Matrikon Inc. (Canada)

    2011-07-01

    The Long Lake project, operated by Nexen and situated in the Athabasca Oil Sands area in Alberta, Canada is a steam assisted gravity drainage scheme. In such thermal recovery processes, access to real time information is crucial. Nexen used specific tools to optimize monitoring in its Long Lake project and the aim of this paper is to present those customized well and facilities dashboards and reservoir trends. Real time and historical data on pressure, temperature injection and production rates are used in a Honeywell PHD Historian connected to a Delta-V DCS system to optimize recovery from the deposit. Results showed that these enhanced monitoring capabilities provided Nexen the ability to react rapidly to abnormal conditions, which resulted in significant financial benefits. The implementation of dashboard and reservoir trends in its Long Lake project helped Nexen to better monitor the reservoir and thus to optimize bitumen recovery.

  3. Work plan for monitor well/groundwater elevation data recorder installation at the Cheney Disposal site, Grand Junction, Colorado

    International Nuclear Information System (INIS)

    1994-09-01

    In May 1990, during the excavation for the Grand Junction, Colorado, Cheney Reservoir disposal cell (Cheney), a water bearing paleochannel was encountered along the northern boundary of the excavation (designated the Northwest Paleochannel). To ensure the long-term integrity of the disposal embankment, remedial actions were taken including the excavation of the paleochannel and underlying material to bedrock, backfilling of the trapezoidal trench with granular material, and placement of a geotextile liner above the granular material. Compacted clay backfill was placed above the reconstructed paleochannel trench, and the northwest corner was restored to the designated grade. Investigation of other paleochannels determined that ground water flow terminated before it migrated as far west as the disposal cell. Therefore, flow in these paleochannels would have no impact on the disposal cell. Although characterization efforts did not indicate the presence of a ground water-bearing paleochannel south of the disposal cell, the potential could not be ruled out. As a best management practice for long-term monitoring at Cheney, two monitor wells will be installed within the paleochannels. One well will be installed within 50 feet (ft) west of the reconstructed Northwest Paleochannel. The second well will be installed near the southwestern (downgradient) corner of the disposal cell. The purposes of these wells are to characterize ground water flow (if any) within the paleochannels and to monitor the potential for water movement (seepage) into or out of the disposal cell. Initial monitoring of the paleochannels will consist of water level elevation measurement collection and trend analysis to evaluate fluctuations in storage. The purpose of this document is to describe the work that will be performed and the procedures that will be followed during installation of two ground water monitor wells and two ground water elevation data recorders (data loggers) at Cheney

  4. Investigation of Rheological Impacts on the Defense Waste Processing Facility's Sludge Slurry Feed as Insoluble Solids and Wash Endpoints are Adjusted

    International Nuclear Information System (INIS)

    Fellinger, T. L.; Howard, S.J.; Lee, M.C.; Galloway, R.H.

    2006-01-01

    The Savannah River Site (SRS) is currently pursuing an aggressive program to empty its High Level Waste (HLW) tanks and immobilize its radioactive waste into a durable borosilicate glass in the Defense Waste Processing Facility (DWPF). To create a batch of feed for the DWPF, several tanks of radioactive sludge slurry are combined into one of the million gallon (i.e. 3.79 E06 liters) feed tanks for DWPF. Once these sludge slurries are combined, the soluble sodium and weight percent total solids are adjusted by a 'washing' process. The 'washing' process involves diluting the soluble sodium of the sludge slurry with inhibited water (0.015 M NaOH and 0.015 M NaNO 2 ) and allowing the sludge slurry to settle into two layers. The two layers in the tank consist of a clear supernate on top and a layer of settled sludge solids on the bottom. The clear supernate layer is then decanted to another hold tank. This 'washing' process is repeated until the desired wash endpoint (i.e. sodium concentration in the supernate) and weight percent total solids are achieved. A final washed batch of feed consists of approximately 500,000 gallons (i.e. 1.89 E06 liters). DWPF has already processed three batches of feed and is currently processing a fourth. Prior to processing a batch of feed in the DWPF, it must be well characterized. Samples of the prepared feed batch are sent to the Savannah River National Laboratory (SRNL) for this characterization. As a part of the SRNL characterization for the fourth batch, rheology measurements were performed. Measurements were performed at different weight percent insoluble solids loadings to mimic potential facility processing scenarios (i.e. mixing/pumping of concentrated sludge slurry). In order to determine the influence of the soluble Na on the rheological properties of the sample, the supernate of the 'as received' sample was adjusted from 1 M soluble Na to 0.5 M soluble Na by using a lab scale version of the 'washing' process. Rheology

  5. High-resolution gravity and seismic-refraction surveys of the Smoke Tree Wash area, Joshua Tree National Park, California

    Science.gov (United States)

    Langenheim, Victoria E.; Rymer, Michael J.; Catchings, Rufus D.; Goldman, Mark R.; Watt, Janet T.; Powell, Robert E.; Matti, Jonathan C.

    2016-03-02

    We describe high-resolution gravity and seismic refraction surveys acquired to determine the thickness of valley-fill deposits and to delineate geologic structures that might influence groundwater flow beneath the Smoke Tree Wash area in Joshua Tree National Park. These surveys identified a sedimentary basin that is fault-controlled. A profile across the Smoke Tree Wash fault zone reveals low gravity values and seismic velocities that coincide with a mapped strand of the Smoke Tree Wash fault. Modeling of the gravity data reveals a basin about 2–2.5 km long and 1 km wide that is roughly centered on this mapped strand, and bounded by inferred faults. According to the gravity model the deepest part of the basin is about 270 m, but this area coincides with low velocities that are not characteristic of typical basement complex rocks. Most likely, the density contrast assumed in the inversion is too high or the uncharacteristically low velocities represent highly fractured or weathered basement rocks, or both. A longer seismic profile extending onto basement outcrops would help differentiate which scenario is more accurate. The seismic velocities also determine the depth to water table along the profile to be about 40–60 m, consistent with water levels measured in water wells near the northern end of the profile.

  6. EBR-II Primary Tank Wash-Water Alternatives Evaluation

    International Nuclear Information System (INIS)

    Demmer, R.; Heintzelman, J.; Squires, L.; Meservey, R.

    2009-01-01

    The EBR-II reactor at Idaho National Laboratory was a liquid sodium metal cooled reactor that operated for 30 years. Approximately 1100 kg of residual sodium remained in the primary system after draining the bulk sodium. To stabilize the remaining sodium, both the primary and secondary systems were treated with a purge of moist carbon dioxide. The passivation treatment was stopped in 2005 and the primary system is maintained under a blanket of dry carbon dioxide. Approximately 670 kg of sodium metal remains in the primary system in locations that were inaccessible to passivation treatment or in pools of sodium that were too deep for complete penetration of the passivation treatment. The EBR-II reactor was permitted by the Idaho Department of Environmental Quality (DEQ) in 2002 under a RCRA permit that requires removal of all remaining sodium. The proposed baseline closure method would remove the large components from the primary tank, fill the primary system with water, react the remaining sodium with the water and dissolve the reaction products in about 100,000 gallons of wash water. On February 19-20, 2008, a workshop was held in Idaho Falls, Idaho, to evaluate alternatives that could meet the RCRA permit clean closure requirements and minimize the quantity of hazardous waste generated by the cleanup process. The workshop convened a panel of national and international sodium cleanup specialists, subject matter experts from the INL, and the EBR-II Wash Water Project team that organized the workshop. The workshop was conducted by a trained facilitator using Value Engineering techniques to elicit the most technically sound solutions from the workshop participants. A brainstorming session was held to identify possible alternative treatment methods that would meet the primary functions and criteria of neutralizing the hazards, maximizing byproduct removal and minimizing waste generation. An initial list of some 20 probable alternatives was evaluated and refined down

  7. 77 FR 8895 - Jimbilnan, Pinto Valley, Black Canyon, Eldorado, Ireteba Peaks, Nellis Wash, Spirit Mountain, and...

    Science.gov (United States)

    2012-02-15

    ..., Pinto Valley, Black Canyon, Eldorado, Ireteba Peaks, Nellis Wash, Spirit Mountain, and Bridge Canyon..., Eldorado, Ireteba Peaks, Nellis Wash, Spirit Mountain, and Bridge Canyon Wilderness Areas, Lake Mead... wilderness character; providing for reasonable use of Spirit Mountain and adjacent areas in a manner meeting...

  8. A Study on the Removal of Cesium in Soil Contaminated with Radiation Using a Soil Washing Process

    Energy Technology Data Exchange (ETDEWEB)

    Park, Ukryang; Kim, Gyenam; Kim, Seungsoo; Park, Hyemin; Kim, Wansuk; Moon, Jaikwon [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2013-05-15

    The first principle is related with the washing process which is carried out to transfer the contaminated mass from the soil to water by dissolving it with a cleansing solution. The second is concerned with the size of the separation process which focuses on the reduction of the volume by separating the subject matters based on the different sizes of the soil. The complex agents used in the soil washing process include HCl, Oxalic acid, Citric acid, CaCl{sub 2}, BaCl{sub 2}, NH{sub 4}NO{sub 3}, and NaOH. It is known that the complex-forming capacity of such complex agents and radionuclides influences the decontamination from the soil. Also, since the forms of the chemical species related with the complex agents and the surface potential of the soil vary based on the changes of acidity observed in the cleansing solution, the level of acidity in the cleansing solution can be regarded as a factor that influences the decontamination. Therefore, in this study, H{sub 2}SO{sub 4} was selected as the complex agent and used to check the influence of the temperature when the subject contaminated soil was washed. Then, by applying the sieve grading process with a sieve-shaker, the size separation process was carried out to measure the level of radiation for each size. By washing the contaminated soil separated into different sizes with the complex agent H{sub 2}SO{sub 4}, the different removal tendencies for each size were considered. After selecting the complex agent H{sub 2}SO{sub 4} and checking the influence of temperature when the contaminated soil was washed based on the solid-liquid ratio of 1g:2ml, it was found that the heat washing process at a temperature of 95 .deg. C showed a higher level of efficiency for the removal of Cs compared to the case of the non-heat washing process. Also, according to the results given by the process of considering the different removal tendencies for each size based on the heat washing process after the sieve grading process was

  9. Chemical changes in silver carp (Hypophthalmichthys molitrix) minced muscle during frozen storage: Effect of a previous washing process

    Energy Technology Data Exchange (ETDEWEB)

    Asgharzadeh, A.; Shabanpour, B.; Aubourg, S. P.; Hosseini, H.

    2010-07-01

    previous washing process Silver carp (Hypophthalmichthys molitrix) has acquired great attention because of its increasing farming production and application in the surimi-product commercialization. This work focuses on the effect of a washing process followed by frozen storage (6 months; -18 degree centigrade) on the quality of minced silver carp muscle. A previous washing step has led to a positive effect on fish quality according to marked content decreases in expressible moisture, volatile amines, free fatty acids and thiobarbituric acid reactive substances; such quality performances were maintained throughout the frozen storage. On the other hand, most indexes tested showed quality losses throughout the frozen storage in both washed and unwashed fish material; however, water holding capacity (WHC) remained unchanged in washed fish throughout the frozen storage. Among quality indexes, a special attention should be given to the expressible moisture value and accordingly the WHC, as being closely related to the gel forming ability in order to obtain surimi-type commercial products. (Author) 46 refs.

  10. Removal of Pb, Zn, and Cd from contaminated soil by new washing agent from plant material.

    Science.gov (United States)

    Cao, Yaru; Zhang, Shirong; Wang, Guiyin; Huang, Qinling; Li, Ting; Xu, Xiaoxun

    2017-03-01

    Soil washing is an effective approach to remove soil heavy metals, and the washing agent is generally regarded as one of the primary factors in the process, but there is still a lack of efficient and eco-friendly agents for this technique. Here, we showed that four plant washing agents-from water extracts of Coriaria nepalensis (CN), Clematis brevicaudata (CB), Pistacia weinmannifolia (PW), and Ricinus communis (RC)-could be feasible agents for the removal of soil lead (Pb), zinc (Zn), and cadmium (Cd). The metal removal efficiencies of the agents increased with their concentrations from 20 to 80 g L -1 , decreased with the increasing solution pH, and presented different trends with the reaction time increasing. CN among the four agents had the highest removal efficiencies of soil Pb (62.02%) and Zn (29.18%) but owned the relatively low Cd removal efficiencies (21.59%). The Fourier transform infrared spectroscopy showed that the abilities of plant washing agents for the removal of soil heavy metals may result from bioactive substances with specific functional groups such as -COOH, -NH 2 , and -OH. Our study provided CN as the best washing agents for the remediation of contaminated soil by heavy metals.

  11. Viscoelastic Properties of Extracellular Polymeric Substances Can Strongly Affect Their Washing Efficiency from Reverse Osmosis Membranes.

    Science.gov (United States)

    Ferrando Chavez, Diana Lila; Nejidat, Ali; Herzberg, Moshe

    2016-09-06

    The role of the viscoelastic properties of biofouling layers in their removal from the membrane was studied. Model fouling layers of extracellular polymeric substances (EPS) originated from microbial biofilms of Pseudomonas aeruginosa PAO1 differentially expressing the Psl polysaccharide were used for controlled washing experiments of fouled RO membranes. In parallel, adsorption experiments and viscoelastic modeling of the EPS layers were conducted in a quartz crystal microbalance with dissipation (QCM-D). During the washing stage, as shear rate was elevated, significant differences in permeate flux recovery between the three different EPS layers were observed. According to the amount of organic carbon remained on the membrane after washing, the magnitude of Psl production provides elevated resistance of the EPS layer to shear stress. The highest flux recovery during the washing stage was observed for the EPS with no Psl. Psl was shown to elevate the layer's shear modulus and shear viscosity but had no effect on the EPS adhesion to the polyamide surface. We conclude that EPS retain on the membrane as a result of the layer viscoelastic properties. These results highlight an important relation between washing efficiency of fouling layers from membranes and their viscoelastic properties, in addition to their adhesion properties.

  12. Effectiveness Of Different House-Hold Hand Washing Agents On ...

    African Journals Online (AJOL)

    Hand hygiene is a very important procedure in infection control. Washing agents commonly in use were investigated for their effectiveness in reducing hand floral and cotton towel was used as drying agent. Agents studied include; water alone, carex soap, dettol, and imperial leather. The hands were inoculated (deliberate ...

  13. Wash fastness improvement of malachite green-dyed cotton fabrics ...

    Indian Academy of Sciences (India)

    Administrator

    Nano-size features of both silica and titania nanosols are predicted to enhance the wash fastness of ... The cotton fabric was obtained from traditional market and was previously tested to contain fully cellulose ..... The authors acknowledge financial support of DP2M,. Directorate General of Higher Education, Indonesia,.

  14. WASH and WAVE actin regulators of the Wiskott-Aldrich syndrome protein (WASP) family are controlled by analogous structurally related complexes.

    Science.gov (United States)

    Jia, Da; Gomez, Timothy S; Metlagel, Zoltan; Umetani, Junko; Otwinowski, Zbyszek; Rosen, Michael K; Billadeau, Daniel D

    2010-06-08

    We recently showed that the Wiskott-Aldrich syndrome protein (WASP) family member, WASH, localizes to endosomal subdomains and regulates endocytic vesicle scission in an Arp2/3-dependent manner. Mechanisms regulating WASH activity are unknown. Here we show that WASH functions in cells within a 500 kDa core complex containing Strumpellin, FAM21, KIAA1033 (SWIP), and CCDC53. Although recombinant WASH is constitutively active toward the Arp2/3 complex, the reconstituted core assembly is inhibited, suggesting that it functions in cells to regulate actin dynamics through WASH. FAM21 interacts directly with CAPZ and inhibits its actin-capping activity. Four of the five core components show distant (approximately 15% amino acid sequence identify) but significant structural homology to components of a complex that negatively regulates the WASP family member, WAVE. Moreover, biochemical and electron microscopic analyses show that the WASH and WAVE complexes are structurally similar. Thus, these two distantly related WASP family members are controlled by analogous structurally related mechanisms. Strumpellin is mutated in the human disease hereditary spastic paraplegia, and its link to WASH suggests that misregulation of actin dynamics on endosomes may play a role in this disorder.

  15. Documentation of a decision framework to support enhanced sludge washing

    International Nuclear Information System (INIS)

    Brothers, A.J.

    1995-01-01

    This document describes a proposed decision model that, if developed to its fullest, can provide a wide range of analysis options and insights to pretreatment/sludge washing alternatives. A recent decision has been made to terminate this work

  16. Sequential Washing with Electrolyzed Alkaline and Acidic Water Effectively Removes Pathogens from Metal Surfaces.

    Directory of Open Access Journals (Sweden)

    Yuichiro Nakano

    Full Text Available Removal of pathogenic organisms from reprocessed surgical instruments is essential to prevent iatrogenic infections. Some bacteria can make persistent biofilms on medical devices. Contamination of non-disposable equipment with prions also represents a serious risk to surgical patients. Efficient disinfection of prions from endoscopes and other instruments such as high-resolution cameras remains problematic because these instruments do not tolerate aggressive chemical or heat treatments. Herein, we develop a new washing system that uses both the alkaline and acidic water produced by electrolysis. Electrolyzed acidic water, containing HCl and HOCl as active substances, has been reported to be an effective disinfectant. A 0.15% NaCl solution was electrolyzed and used immediately to wash bio-contaminated stainless steel model systems with alkaline water (pH 11.9 with sonication, and then with acidic water (pH 2.7 without sonication. Two bacterial species (Staphylococcus aureus and Pseudomonas aeruginosa and a fungus (Candida albicans were effectively removed or inactivated by the washing process. In addition, this process effectively removed or inactivated prions from the stainless steel surfaces. This washing system will be potentially useful for the disinfection of clinical devices such as neuroendoscopes because electrolyzed water is gentle to both patients and equipment and is environmentally sound.

  17. Comparative characterization of the quaternary deposits of Northwest Peninsular Malaysia by wash boring and CPTU site investigation methods

    Science.gov (United States)

    Selamat, Mohamad R.; Rosli, Ros N.; Ramli, Muhd H.; Azmi, Mastura; Kumaravelu, Prakash; Govindasamy, Darvintharen

    2017-10-01

    A site investigation by wash boring method was carried out in the compound of the Engineering Campus, Universiti Sains Malaysia, in Northwest Peninsular Malaysia. The subsurface soils of the region are known to be comprised of quaternary deposits including the prominent marine clays of the Gula formation. The conventional Standard Penetration Test, or SPT, was carried out for every 1.5m depth. The 18 disturbed samples collected were tested for grain size distribution, Atterberg limits, and specific gravity; and categorized according to the unified soil classification system. The results indicate low SPT numbers, or SPTN, i.e. SPTN8 for depths deeper than 12m. Samples from shallower than 12m were mostly classified as low plasticity clay, or CL, which represents the soft marine clay while the underlying materials were mostly sands, namely poorly graded sand, or SP, silty sand, or SM, clayey sand, or SC, and well graded sand, or SW. Another site investigation by the CPTU method was also carried out 5m from the wash boring position, penetrating the entire soft clay stratum, thus giving another marine clay characterization in addition to the one given by the first method. The CPTU results generally gave SPTN≤2 for depths lesser than 8m, 2≤;SPTN≤4 for depths between 8 and 12m, and SPTN=23 at 12.5m, where the CPTU test terminated. The CPTU method classified the soft materials as sensitive fine grains, clays, and clayey silts to silty clays. Thus the CPTU results did not agree very well with the conventional wash boring SPT results in terms of the SPTN obtained. Nevertheless both methods equally identified the prominent presence of the soft marine clay stratum in the top 12.5m and the underlying strong sandy bed with higher bearing capacity values.

  18. Radioactive demonstration of the ''late wash'' Precipitate Hydrolysis Process

    International Nuclear Information System (INIS)

    Bibler, N.E.; Ferrara, D.M.; Ha, B.C.

    1992-01-01

    This report presents results of the radioactive demonstration of the DWPF Precipitate Hydrolysis Process as it would occur in the ''late wash'' flowsheet in the absence of hydroxylamine nitrate. Radioactive precipitate containing Cs-137 from the April, 1983, in-tank precipitation demonstration in Tank 48 was used for these tests

  19. Comparative studies on dyeing rate migration and wash fastness ...

    African Journals Online (AJOL)

    Migration and diffusion properties of synthesized azo dyes from 2-aminothiazole derivatives applied on commercial grade undyed cellulose acetate (CA) and cellulose triacetate (CTA) were investigated using dyeing conditions of 2% on weight of fabric (owf), 50:1 liquor ratio and subjected to ISO3 and ISO4 standard wash ...

  20. Ink and Wash Painting for Children with Visual Impairment

    Science.gov (United States)

    Shih, Chih-Ming; Chao, Hsin-Yi

    2010-01-01

    Five children with visual impairments received instruction in drawing, using ink and wash painting and calligraphy techniques. A special system developed by a blind Taiwanese Chinese calligrapher, Tsann-Cherng Liaw, was used to help the children orient and refine their work. Children's performance on simple drawing tasks was compared before and…

  1. Knowledge, Attitude and Practice of Hand washing among Street vendors in Campus of Universitas Padjadjaran, West Java from June-November 2012

    Directory of Open Access Journals (Sweden)

    Tajul Al Adib

    2015-09-01

    Full Text Available Background: Hand washing is a moderate step in preventing communicable diseases. Communicable diseases like diarrhea and respiratory tract infection can be reduced significantly just by practicing hand washing. Most of the people already knew how to wash their hand, but some of them still did not understand the objective and the correct ways of performing hand washing. The aim of the study was to evaluate knowledge, attitude and practice of hand washing among street vendors. Methods: A descriptive study was conducted to 30 street vendors at the gate of Universitas Padjadjaran Campus from June to November 2012. The inclusion criterias were street vendors involved in food preparation, cooking, mixing, and willing to participate in this study. A questionnaire was developed to identify the knowledge, attitude and practice of hand washing. The level of the variable measured was divided into 3 categories: good, moderate, and poor. The collected data were analyzed and presented in table. Results: There were 12/30 of street vendors classified as having moderate knowledge and 25/30 as having good attitude and good practice of hand washing. Conclusions: The street vendors at the gate of Universitas Padjadjaran Campus had moderate knowledge, good attitude and good practice of hand washing.

  2. Microbiological evaluation of sludge during an improvement process applying the washing technique (selective pressure)

    International Nuclear Information System (INIS)

    Molina P, Francisco; Gonzalez, Maria Elena; Gonzalez, Luz Catalina

    2001-01-01

    In this investigation, the microbial consortiums were evaluated by using characterization by trophic groups and related groups by their sensibility to oxygen, as well as the specific methanogenic activity (SMA) of an acclimated sludge, starting from an aerobium sludge corning from a residual water treatment plant. Later, the technique of improvement by washing was applicated to this sludge, getting inoculum for the starting of an anaerobic reactor of the kind UASB (treatment reactor). At the same time, a control reactor was operated, inoculated with acclimated sludge. Both reactors were operated during 120 days, using brown sugar as substrate, the experimental phase included dates up to 70 operation days, characterizing the sludge at the end of this period. The SMA was analysed using acetic and formic acids as substrates. The results showed activities between 0,45 and 1,39 g DQO-CH 4 /SSV -d. for both substrates. At the end of the experimental phase of the UASB reactor, the sulphate reducer bacteria from the acetate and the lactate were observed as predominant group, followed by the methanogenic hydrogenophilic bacteria. It is important to notice that, with the application of the sludge washing technique, all the tropic groups were increased, with the exception of the lactate fermentative bacteria

  3. The Design and Implementation of the Remote Centralized-Monitoring System of Well-Control Equipment Based on RFID Technique

    Directory of Open Access Journals (Sweden)

    Luo Bin

    2017-01-01

    Full Text Available At present, in domestic for the management of well control equipment continue to the traditional way of nameplates identifies and paper-based registration, there are many issues like the separation of data information of device, easy lose, difficult query, confused management and many other problems, which will make the problem device into the well field, and then resulting in well control runaway drilling accident. To solve the above problems, this paper put forward to the integrated remote centralized-monitoring management mode of the well-control equipment. Taking the advantages of IOT technology, adopting the RFID technology, and combining with the remote transmission, this paper designs the remote centralized-monitoring system of well-control equipment based on RFID, which realizes the intelligent management of well-control equipment and meets the actual demand of the well-control equipment safe use and timely scheduling, and it has the ability of field application.

  4. Adsorption Removal of Glycidyl Esters from Palm Oil and Oil Model Solution by Using Acid-Washed Oil Palm Wood-Based Activated Carbon: Kinetic and Mechanism Study.

    Science.gov (United States)

    Cheng, Weiwei; Liu, Guoqin; Wang, Xuede; Han, Lipeng

    2017-11-08

    Acid-washed oil palm wood-based activated carbon (OPAC) has been investigated for its potential application as a promising adsorbent in the removal of glycidyl esters (GEs) from both palm oil and oil model (hexadecane) solution. It was observed that the removal rate of GEs in palm oil was up to >95%, which was significantly higher than other adsorbents used in this study. In batch adsorption system, the adsorption efficiency and performance of acid-washed OPAC were evaluated as a function of several experimental parameters such as contact time, initial glycidyl palmitate (PGE) concentration, adsorbent dose, and temperature. The Langmuir, Freundlich, and Dubinin-Radushkevich models were used to describe the adsorption equilibrium isotherm, and the equilibrium data were fitted best by the Langmuir model. The maximum adsorption capacity of acid-washed OPAC was found to be 36.23 mg/g by using the Langmuir model. The thermodynamic analysis indicated that the adsorption of PGE on acid-washed OPAC was an endothermic and physical process in nature. The experimental data were fitted by using pseudo-first-order, pseudo-second-order, and intraparticle diffusion models. It was found that the kinetic of PGE adsorption onto acid-washed OPAC followed well the pseudo-second-order model for various initial PGE concentrations and the adsorption process was controlled by both film diffusion and intraparticle diffusion. The desorption test indicated the removal of GEs from palm oil was attributed to not only the adsorption of GEs on acid-washed OPAC, but also the degradation of GEs adsorbed at activated sites with acidic character. Furthermore, no significant difference between before and after PGE adsorption in oil quality was observed.

  5. Estimated ground-water recharge from streamflow in Fortymile Wash near Yucca Mountain, Nevada

    International Nuclear Information System (INIS)

    Savard, C.S.

    1998-01-01

    The two purposes of this report are to qualitatively document ground-water recharge from stream-flow in Fortymile Wash during the period 1969--95 from previously unpublished ground-water levels in boreholes in Fortymile Canyon during 1982--91 and 1995, and to quantitatively estimate the long-term ground-water recharge rate from streamflow in Fortymile Wash for four reaches of Fortymile Wash (Fortymile Canyon, upper Jackass Flats, lower Jackass Flats, and Amargosa Desert). The long-term groundwater recharge rate was estimated from estimates of the volume of water available for infiltration, the volume of infiltration losses from streamflow, the ground-water recharge volume from infiltration losses, and an analysis of the different periods of data availability. The volume of water available for infiltration and ground-water recharge in the four reaches was estimated from known streamflow in ephemeral Fortymile Wash, which was measured at several gaging station locations. The volume of infiltration losses from streamflow for the four reaches was estimated from a streamflow volume loss factor applied to the estimated streamflows. the ground-water recharge volume was estimated from a linear relation between infiltration loss volume and ground-water recharge volume for each of the four reaches. Ground-water recharge rates were estimated for three different periods of data availability (1969--95, 1983--95, and 1992--95) and a long-term ground-water recharge rate estimated for each of the four reaches

  6. Estimated ground-water recharge from streamflow in Fortymile Wash near Yucca Mountain, Nevada

    Energy Technology Data Exchange (ETDEWEB)

    Savard, C.S.

    1998-10-01

    The two purposes of this report are to qualitatively document ground-water recharge from stream-flow in Fortymile Wash during the period 1969--95 from previously unpublished ground-water levels in boreholes in Fortymile Canyon during 1982--91 and 1995, and to quantitatively estimate the long-term ground-water recharge rate from streamflow in Fortymile Wash for four reaches of Fortymile Wash (Fortymile Canyon, upper Jackass Flats, lower Jackass Flats, and Amargosa Desert). The long-term groundwater recharge rate was estimated from estimates of the volume of water available for infiltration, the volume of infiltration losses from streamflow, the ground-water recharge volume from infiltration losses, and an analysis of the different periods of data availability. The volume of water available for infiltration and ground-water recharge in the four reaches was estimated from known streamflow in ephemeral Fortymile Wash, which was measured at several gaging station locations. The volume of infiltration losses from streamflow for the four reaches was estimated from a streamflow volume loss factor applied to the estimated streamflows. the ground-water recharge volume was estimated from a linear relation between infiltration loss volume and ground-water recharge volume for each of the four reaches. Ground-water recharge rates were estimated for three different periods of data availability (1969--95, 1983--95, and 1992--95) and a long-term ground-water recharge rate estimated for each of the four reaches.

  7. Irreversible Wash Aid Additive for Cesium Mitigation. Small-Scale Demonstration and Lessons Learned

    Energy Technology Data Exchange (ETDEWEB)

    Kaminski, Michael [Argonne National Lab. (ANL), Argonne, IL (United States)

    2015-01-01

    The Irreversible Wash Aid Additive process has been under development by the U.S. Environmental Protection Agency (EPA) and Argonne National Laboratory (Argonne). This process for radioactive cesium mitigation consists of a solution to wash down contaminated structures, roadways, and vehicles and a sequestering agent to bind the radionuclides from the wash water and render them environmentally immobile. The purpose of this process is to restore functionality to basic services and immediately reduce the consequences of a radiologically-contaminated urban environment. Research and development have resulted in a down-selection of technologies for integration and demonstration at the pilot-scale level as part of the Wide Area Recovery and Resiliency Program (WARRP) under the Department of Homeland Security and the Denver Urban Area Security Initiative. As part of developing the methods for performing a pilot-scale demonstration at the WARRP conference in Denver in 2012, Argonne conducted small-scale field experiments at Separmatic Systems. The main purpose of these experiments was to refine the wash water collection and separations systems and demonstrate key unit operations to help in planning for the large scale demonstration in Denver. Since the purpose of these tests was to demonstrate the operations of the system, we used no radioactive materials. After a brief set of experiments with the LAKOS unit to familiarize ourselves with its operation, two experiments were completed on two separate dates with the Separmatic systems.

  8. In-situ high-resolution gamma-spectrometric survey of burial ground-monitoring wells

    International Nuclear Information System (INIS)

    Bowman, W.W.

    1981-09-01

    In situ high resolution gamma-ray spectrometry with an intrinsic germanium detector assembly of special design surveyed the burial ground monitoring wells to locate and identify gamma emitters that may have migrated from the burial trenches toward the water table. Gamma-ray spectra were acquired as a function of depth in each well and recorded on magnetic tape. These spectra were reduced by a series of computer programs to produce count rate versus depth profiles for natural and man-made activities. The original spectra and the profiles have been archived on magnetic tape for comparison with similar future surveys. Large amounts of man-made activities were observed in some of the burial trenches; however, below the trench bottoms, only very low but detectable amounts of 60 Co and 137 Cs were observed in eleven wells. The highest level of man-made gamma activity observed below the trench bottoms has a count rate roughly equal to that observed for uranium daughter activities which are natural to the subsoil

  9. Compound washing remediation and response surface analysis of lead-contaminated soil in mining area by fermentation broth and saponin.

    Science.gov (United States)

    Zhang, Hongjiao; Wang, Zhengwei; Gao, Yuntao

    2018-03-01

    The development of eluent is the key to soil washing remediation, and a compound eluent was constructed using the prepared citric acid fermentation broth and saponin in this study. It displayed a good washing performance for Pb, Cu, Cr, and Cd in red soil, and the removal rates, especially Pb, gained an improvement compared with a single eluent. Based on this, the compound eluent was applied to remediation of Pb-contaminated soil in mining area; the desorption of Pb is a heterogeneous diffusion process, and Pb in large particle size soil is relatively easy to remove. An available response surface analysis model was established; its P  washing time > saponin concentration, and liquid-to-solid ratio and washing time show interaction. Moreover, the Pb removal rate can reach 56.20% under the optimized conditions: 0.25% saponin concentration, 20 mL/g liquid-to-solid ratio, and 320-min washing time, which is close to the predicted value of 56.20% with a difference of 1.41%. In addition, most of the active Pb was removed and environmental risks were lowered after washing.

  10. Characteristics and settling behaviour of particles from blast furnace flue gas washing.

    Science.gov (United States)

    Kiventerä, Jenni; Leiviskä, Tiina; Keski-Ruismäki, Kirsi; Tanskanen, Juha

    2016-05-01

    A lot of particles from iron-making are removed with blast furnace off-gas and routed to the gas cleaning system. As water is used for cleaning the gas, the produced wash water contains a large amount of particles such as valuable Fe and C. However, the presence of zinc prevents recycling. In addition, the high amount of calcium results in uncontrolled scaling. Therefore, the properties of the wash water from scrubber and sludge, from the Finnish metal industry (SSAB Raahe), were evaluated in this study. Size fractionation of wash water revealed that Fe, Zn, Al, Mn, V, Cr and Cd appeared mainly in the larger fractions (>1.2 μm) and Na, Mg, Si, Ni, K, Cu and As appeared mainly in the smaller fractions (<1.2 μm) or in dissolved form. Calcium was found both in the larger fractions and dissolved (∼60 mg/L). Most of the particles in wash water were included in the 1.2-10 μm particle size and were settled effectively. However, a clear benefit was observed when using a chemical to enhance particle settling. In comparison to 2.5 h of settling without chemical, the turbidity was further decreased by about 94%, iron 85% and zinc 50%. Coagulation-flocculation experiments indicated that both low and high molecular weight cationic polymers could provide excellent purification results in terms of turbidity. Calcium should be removed by other methods. The particles in sludge were mostly in the 2-4 μm or 10-20 μm fractions. Further sludge settling resulted in high solids removal. Copyright © 2016 Elsevier Ltd. All rights reserved.

  11. Test installation for studying erosion-corrosion of metals for coal washing plants

    Energy Technology Data Exchange (ETDEWEB)

    Hoey, G. R.; Dingley, W.; Wiles, C. T.

    1979-02-15

    A test installation was constructed for investigating erosion-corrosion of metals by coal-water slurries. Erosion-corrosion tests of mild steel panels were conducted using slurries of alundum, quartz, washed coal and coal refuse. Wear rates were found to depend on type of abrasive, particle size and water conductivity and were reduced by cathodic protection and inhibitors. Cathodic protection of mild steel in coal slurries containing sulphate ion reduced wear by 90% and 86% for stationary and rotating panels, respectively. This study has demonstrated that the successful application of corrosion control techniques would reduce metal wastage in coal washing plants. The test installation is considered suitable for developing the techniques.

  12. Performance of ceramic ultrafiltration and reverse osmosis membranes in treating car wash wastewater for reuse.

    Science.gov (United States)

    Moazzem, Shamima; Wills, Jamie; Fan, Linhua; Roddick, Felicity; Jegatheesan, Veeriah

    2018-03-01

    Reusing treated effluents in industries is a great option to conserve freshwater resources. For example, car wash centres all over Australia are estimated to use 17.5 billion litres of water and discharge it as wastewater and spend $75 million a year for both purchasing fresh water and for treating and/or discharging the wastewater. Therefore, it is important to develop simple but reliable systems that can help to treat and reuse car wash wastewater. Significant savings could also be associated with the implementation of such systems. This study evaluates the performance of granular and membrane filtration systems with coagulation/flocculation and sedimentation in treating car wash wastewater for the purpose of reuse. Overall, 99.9% of turbidity, 100% of suspended solids and 96% of COD were removed from the car wash wastewater after treating by coagulation, flocculation, sedimentation, sand filtration, ceramic ultrafiltration and reverse osmosis and the treated water meets the standards required for class A recycled water in Australia and standards imposed in Belgium and China. The treated water can be reused. However, optimisation is required to reduce the sludge produced by this system.

  13. Effectiveness of semen washing to prevent HIV transmission and assist pregnancy in HIV-discordant couples: a systematic review and meta-analysis

    Science.gov (United States)

    Zafer, Maryam; Horvath, Hacsi; Mmeje, Okeoma; van der Poel, Sheryl; Semprini, Augusto; Rutherford, George; Brown, Joelle

    2015-01-01

    Objective To evaluate the effectiveness of semen washing in HIV-discordant couples in which the male partner is infected Design Systematic review and meta-analysis Setting All countries Patient(s) Forty single-arm, open label studies among HIV-discordant couples that underwent intrauterine insemination (IUI) or in vitro fertilization (IVF) with or without intracytoplasmic sperm injection (ICSI) using washed semen Intervention(s) Semen washing followed by IUI, IVF, or IVF/ICSI Main outcome measure(s) Primary outcome: HIV transmission to HIV-uninfected women; secondary outcomes: HIV transmission to newborns and proportion of couples achieving a clinical pregnancy Result(s) No HIV transmission occurred in 11,585 cycles of assisted reproduction using washed semen among 3,994 women (95% confidence interval [CI] = 0–0.0001). Among the subset of HIV-infected men without plasma viral suppression at the time of semen washing, no HIV seroconversions occurred among 1,023 women following 2,863 cycles of assisted reproduction using washed semen (95%CI= 0–0.0006). Studies that measured HIV transmission to infants reported no cases of vertical transmission (0/1,026, 95% CI= 0–0.0029). Overall, 56.3% (2,357/4,184, 95%CI=54.8%–57.8%) of couples achieved a clinical pregnancy using washed semen. Conclusion(s) Semen washing appears to significantly reduce the risk of transmission in HIV-discordant couples desiring children, regardless of viral suppression in the male partner. There are no randomized, controlled studies or studies from low-income countries, especially those with a large burden of HIV. Continued development of lower-cost semen washing and assisted reproduction technologies is needed. Integration of semen washing into HIV prevention interventions could help further reduce the spread of HIV. PMID:26688556

  14. Ultrasonic and mechanical soil washing processes for the remediation of heavy-metal-contaminated soil

    Science.gov (United States)

    Kim, Seulgi; Lee, Wontae; Son, Younggyu

    2016-07-01

    Ultrasonic/mechanical soil washing process was investigated and compared with ultrasonic process and mechanical process using a relatively large lab-scale sonoreactor. It was found that higher removal efficiencies were observed in the combined processes for 0.1 and 0.3 M HCl washing liquids. It was due to the combination effects of macroscale removal for the overall range of slurry by mechanical mixing and microscale removal for the limited zone of slurry by cavitational actions.

  15. Proven and potential clinical benefits of washing red blood cells before transfusion: current perspectives

    Directory of Open Access Journals (Sweden)

    Schmidt AE

    2016-08-01

    Full Text Available Amy E Schmidt, Majed A Refaai, Scott A Kirkley, Neil Blumberg Department of Pathology and Laboratory Medicine, University of Rochester Medical Center, Rochester, NY, USA Abstract: Red blood cells (RBCs are washed for a variety of reasons such as to remove excess potassium, cytokines, and other allergen proteins from the supernatant and/or to mitigate the effects of the storage lesion. The storage lesion is a product of RBC aging and include leakage of potassium and chloride from the RBCs, depletion of 2,3-diphosphoglycerate and adenosine triphosphate, loss of phospholipids and cholesterol, exposure of phosphatidylserine, elaboration of lipid mediators, loss of glutathione, autoxidation of hemoglobin to methemoglobin contributing to decreased blood flow viscosity and adherence to endothelial cells, increased microparticle formation, and disruption of NO-mediated vasodilation. A storage lesion is thought to be caused in part by oxidative stress, which is characterized by functional and structural changes to the RBCs. The effects of the RBC storage lesion on patient morbidity and mortality have been studied intensively with mixed results. Here, we will summarize the potential benefits of RBC washing. Notably, all patient-based studies on washed RBCs are single-center, small randomized studies or observational data, which await replication and tests of generalizability. Some of the most promising preliminary data suggest that washed transfusions of red cells and platelets reduce mortality in low risk, younger patients with acute myeloid leukemia, mitigate lung injury, and substantially reduce mortality in cardiac surgery. Larger randomized trials to replicate or refute these findings are urgently needed and, most importantly, have the potential to strikingly improve clinical outcomes following transfusion. Keywords: washed blood, transfusion, immunomodulation, red blood cell

  16. Integrating EDDS-enhanced washing with low-cost stabilization of metal-contaminated soil from an e-waste recycling site.

    Science.gov (United States)

    Beiyuan, Jingzi; Tsang, Daniel C W; Ok, Yong Sik; Zhang, Weihua; Yang, Xin; Baek, Kitae; Li, Xiang-Dong

    2016-09-01

    While chelant-enhanced soil washing has been widely studied for metal extraction from contaminated soils, there are concerns about destabilization and leaching of residual metals after remediation. This study integrated 2-h soil washing enhanced by biodegradable ethylenediaminedisuccinic acid (EDDS) and 2-month stabilization using agricultural waste product (soybean stover biochar pyrolyzed at 300 and 700 °C), industrial by-product (coal fly ash (CFA)), and their mixture. After integration with 2-month stabilization, the leachability and mobility of residual metals (Cu, Zn, and Pb) in the field-contaminated soil were significantly reduced, especially for Cu, in comparison with 2-h EDDS washing alone. This suggested that the metals destabilized by EDDS-washing could be immobilized by subsequent stabilization with biochar and CFA. Moreover, when the remediation performance was evaluated for phytoavailability and bioaccessibility, prior EDDS washing helped to achieve a greater reduction in the bioavailable fraction of metals than sole stabilization treatment. This was probably because the weakly-bound metals were first removed by EDDS washing before stabilization. Both individual and combined applications of biochar and CFA showed comparable effectiveness regardless of the difference in material properties, possibly due to the high level of amendments (150 ton ha(-1)). Based on the mobility and bioaccessibility results, the estimated human health risk (primarily resulting from Pb) could be mitigated to an acceptable level in water consumption pathway or reduced by half in soil ingestion pathway. These results suggest that an integration of EDDS washing with soil stabilization can alleviate post-remediation impacts of residual metals in the treated soil. Copyright © 2016 Elsevier Ltd. All rights reserved.

  17. Hydraulic washing removal efficiencies of Orimulsion from rock surfaces

    International Nuclear Information System (INIS)

    Harper, J.R.; Ward, S.; Sergy, G.

    2002-01-01

    Orimulsion is a fuel alternative composed of 70 per cent bitumen in 30 per cent water. It is shipped from Venezuela to New Brunswick where it is used as fuel oil for power plants. While there have not been any major spills of Orimulsion, it is recognized that very little is known regarding the dispersal and weathering processes of Orimulsion, or the behaviour and cleanup of the product on both rocky and course sediment shorelines. For that reason, this study was conducted to determine the efficiency of hydraulic washing under different water temperatures and pressures to remove bitumen from rocky shorelines. The results of the study make it possible to assess the physical effectiveness of the method and to determine the range of effective operational parameters. The coating protocol was refined to create uniform coating of both dispersed and coalesced bitumen of rock surfaces. The use of a chemical agent for enhancing removal efficiency was also assessed. Orimulsion could reach shorelines as low concentration dispersions of bitumen particles suspended in a water column, or as a high concentration mixture of bitumen, water and air. Granite tiles were coated with uniform coatings of both dispersed and coalesced bitumen. They were then washed under different pressures, temperatures and other treatments. Temperatures of more than 40 degrees C and pressures of more than 76 kPa were needed to effectively remove the bitumen coatings. Weathering significantly increased coating tenacity for dispersed coatings, but did not affect coalesced coating tenacity. Immediate washing was found to be very effective for removing dispersed coating, but not for coalesced coating. Coating tenacity was also affected by submergence times. Pre-treatment of the coating with a dispersion called Corexit significantly improved the removal efficiencies of dispersed coatings, but not coalesced coatings. 6 refs., 10 tabs., 5 figs

  18. Low parameter model to monitor bottom hole pressure in vertical multiphase flow in oil production wells

    Directory of Open Access Journals (Sweden)

    Mohammad Ali Ahmadi

    2016-09-01

    Full Text Available The importance of the flow patterns through petroleum production wells proved for upstream experts to provide robust production schemes based on the knowledge about flow behavior. To provide accurate flow pattern distribution through production wells, accurate prediction/representation of bottom hole pressure (BHP for determining pressure drop from bottom to surface play important and vital role. Nevertheless enormous efforts have been made to develop mechanistic approach, most of the mechanistic and conventional models or correlations unable to estimate or represent the BHP with high accuracy and low uncertainty. To defeat the mentioned hurdle and monitor BHP in vertical multiphase flow through petroleum production wells, inventive intelligent based solution like as least square support vector machine (LSSVM method was utilized. The evolved first-break approach is examined by applying precise real field data illustrated in open previous surveys. Thanks to the statistical criteria gained from the outcomes obtained from LSSVM approach, the proposed least support vector machine (LSSVM model has high integrity and performance. Moreover, very low relative deviation between the model estimations and the relevant actual BHP data is figured out to be less than 6%. The output gained from LSSVM model are closed the BHP while other mechanistic models fails to predict BHP through petroleum production wells. Provided solutions of this study explicated that implies of LSSVM in monitoring bottom-hole pressure can indicate more accurate monitoring of the referred target which can lead to robust design with high level of reliability for oil and gas production operation facilities.

  19. Flood potential of Fortymile Wash and its principal southwestern tributaries, Nevada Test Site, Southern Nevada

    International Nuclear Information System (INIS)

    Squires, R.R.; Young, R.L.

    1984-01-01

    Flood hazards for a 9-mile reach of Fortymile Wash and its principal southwestern tributaries - Busted Butte, Drill Hole, and Yucca Washes - were evaluated to aid in determining possible sites for the storage of high-level radioactive wastes on the Nevada Test Site. Data from 12 peak-flow gaging stations adjacent to the Test Site were used to develop regression relations that would permit an estimation of the magnitude of the 100- and 500-year flood peaks (Q 100 and Q 500 ), in cubic feet per second. The resulting equations are: Q 100 = 482A 0 565 and Q 500 = 2200A 0 571 , where A is the tributary drainage area, in square miles. The estimate of the regional maximum flood was based on data from extreme floods elsewhere in Nevada and in surrounding states. Among seven cross sections on Fortymile Wash, the estimated maximum depths of the 100-year, 500-year, and regional maximum floods are 8, 11, and 29 feet, respectively. At these depths, flood water would remain within the deeply incised channel of the wash. Mean flow velocities would be as great as 9, 14, and 28 feet per second for the three respective flood magnitudes. The study shows that Busted Butte and Drill Hole Washes (9 and 11 cross sections, respectively) would have water depths of up to at least 4 feet and mean flow velocities of up to at least 8 feet per second during a 100-year flood. A 500-year flood would exceed stream-channel capacities at several places, with depths to 10 feet and mean flow velocities to 11 feet per second. The regional maximum flood would inundate sizeable areas in central parts of the two watersheds. At Yucca Wash (5 cross sections), the 100-year, 500-year, and regional maximum floods would remain within the stream channel. Maximum flood depths would be about 5, 9, and 23 feet and mean velocities about 9, 12, and 22 feet per second, respectively, for the three floods

  20. Computer-Based Monitoring and Remote Controlling for Oil Well Pumps Using Scada

    Directory of Open Access Journals (Sweden)

    Rudi Tjiptadi

    2011-12-01

    Full Text Available The research aims to change manually the monitoring and controlling of oil well pumps into a computer-based system using SCADA (Supervisory and Data Acquisition system. To design the protection system which consists of controller unit and display system, RTU (Remote Terminal Unit and MTU (Master Terminal Unit are used. The research results in a controller unit which is able to communicate to personal computer using RS-232 C and an alarm system to protect oil pump motors by detecting sensors installed at the pumps. 

  1. Proper Hand-Washing Techniques in Public Restrooms: Differences in Gender, Race, Signage, and Time of Day

    Science.gov (United States)

    Kinnison, Andrea; Cottrell, Randal R.; King, Keith A.

    2004-01-01

    The purpose of this study was to evaluate hand washing behaviors in public restrooms with and without reminder signs. Gender, race, signage, and time of day were examined to determine if there were differences in hand washing compliance based on these variables. Participants included male and female adults entering restrooms at two public shopping…

  2. Fracture coatings in Topopah Spring Tuff along drill hole wash

    International Nuclear Information System (INIS)

    Carlos, B.A.; Chipera, S.J.; Bish, D.L.

    1994-01-01

    Fracture-lining minerals are being studied as part of site characterization to determine the suitability of Yucca Mountain, Nevada as a potential high level nuclear waste repository. Fracture coatings in the Paintbrush Group provide information on potential flow paths above the water table both toward and away from the potential repository and provide information on the distribution of fracture-lining minerals needed to model thermal effects of waste emplacement. Fracture coatings within the predominantly non-zeolitic Paintbrush Group vary both with depth and laterally across Yucca Mountain, whereas fracture coatings in tuffs below the Paintbrush Group are related to the mineralogy of the tuffs and follow a consistent pattern of distribution with predominantly quartz, calcite, and manganese oxides in the devitrified intervals and mordenite and clinoptilolite in the zeolitic intervals. The zeolites stellerite and heulandite are more abundant in fractures in the Topopah Spring Tuff in drill holes USW G-1 and UE-25 a number-sign l, located along Drill Hole Wash (at the northern end of Yucca Mountain) than in core from other parts of Yucca Mountain. Buesch et al. (2) present evidence for a complex fault system along Drill Hole Wash. To investigate the possibility that the abundant fracture-lining zeolites in USW G-1 and UE-25 a number-sign 1 are related to the Drill Hole Wash fault, the Topopah Spring Tuff was examined in drill cores from USW UZ-14, USW G-1, USW NRG-7/7a, and UE-25 a number-sign l

  3. Pulsed-plasma gas-discharge inactivation of microbial pathogens in chilled poultry wash water.

    Science.gov (United States)

    Rowan, N J; Espie, S; Harrower, J; Anderson, J G; Marsili, L; MacGregor, S J

    2007-12-01

    A pulsed-plasma gas-discharge (PPGD) system was developed for the novel decontamination of chilled poultry wash water. Treatment of poultry wash water in the plasma generation chamber for up to 24 s at 4 degrees C reduced Escherichia coli NCTC 9001, Campylobacter jejuni ATCC 33560, Campylobacter coli ATCC 33559, Listeria monocytogenes NCTC 9863, Salmonella enterica serovar Enteritidis ATCC 4931, and S. enterica serovar Typhimurium ATCC 14028 populations to non-detectable levels ( or = 3 log CFU/ml) in recalcitrant B. cereus NCTC 11145 endospore numbers within 30 s, the level of endospore reduction was dependent on the nature of the sparged gas used in the plasma treatments. Scanning electron microscopy revealed that significant damage occurred at the cellular level in PPGD-treated test organisms. This electrotechnology delivers energy in intense ultrashort bursts, generating products such as ozone, UV light, acoustic and shock waves, and pulsed electric fields that have multiple bactericidal properties. This technology offers an exciting complementary or alternative approach for treating raw poultry wash water and for preventing cross-contamination in processing environments.

  4. Efficacy of household washing treatments for the control of Listeria monocytogenes on salad vegetables.

    Science.gov (United States)

    Nastou, Aikaterini; Rhoades, Jonathan; Smirniotis, Petros; Makri, Ioanna; Kontominas, Michael; Likotrafiti, Eleni

    2012-10-15

    The efficacy of household decontamination methods at reducing Listeria monocytogenes on fresh lettuce (Lactuca sativa), cucumber (Cucumis sativus) and parsley (Petroselinum sativum) was studied. Inoculated vegetable pieces were immersed in washing solutions and surviving L. monocytogenes enumerated. Parameters investigated were storage temperature prior to washing, dipping water temperature, agitation, acetic acid concentration and immersion time. The results indicated that the storage temperature significantly affects the efficacy of dipping vegetables in water for the control of L. monocytogenes, as the reduction in count was greatest when products had been stored at cooler temperatures. Decontamination with acetic acid (up to 2.0% v/v) was shown to have some effect in most cases, but the highest observed decrease in count was 2.6 log cfu/g. Experiments investigating the effect of exposure time to acetic acid (0.5% and 1.0% v/v, up to 30 min immersion) indicated that immersing the vegetables for more than 10 min is of minimal benefit. The most significant factor affecting washing and decontamination efficacy was the vegetable itself: L. monocytogenes colonizing cucumber epidermis was far more resistant to removal by washing and to acid treatment than that on the leafy vegetables, and L. monocytogenes on parsley was the most susceptible. This shows that published decontamination experiments (often performed with lettuce) cannot necessarily be extrapolated to other vegetables. Copyright © 2012 Elsevier B.V. All rights reserved.

  5. Evidence for Legacy Contamination of Nitrate in Groundwater of North Carolina Using Monitoring and Private Well Data Models

    Science.gov (United States)

    Messier, K. P.; Kane, E.; Bolich, R.; Serre, M. L.

    2014-12-01

    Nitrate (NO3-) is a widespread contaminant of groundwater and surface water across the United States that has deleterious effects to human and ecological health. Legacy contamination, or past releases of NO3-, is thought to be impacting current groundwater and surface water of North Carolina. This study develops a model for predicting point-level groundwater NO3- at a state scale for monitoring wells and private wells of North Carolina. A land use regression (LUR) model selection procedure known as constrained forward nonlinear regression and hyperparameter optimization (CFN-RHO) is developed for determining nonlinear model explanatory variables when they are known to be correlated. Bayesian Maximum Entropy (BME) is then used to integrate the LUR model to create a LUR-BME model of spatial/temporal varying groundwater NO3- concentrations. LUR-BME results in a leave-one-out cross-validation r2 of 0.74 and 0.33 for monitoring and private wells, effectively predicting within spatial covariance ranges. The major finding regarding legacy sources NO3- in this study is that the LUR-BME models show the geographical extent of low-level contamination of deeper drinking-water aquifers is beyond that of the shallower monitoring well. Groundwater NO3- in monitoring wells is highly variable with many areas predicted above the current Environmental Protection Agency standard of 10 mg/L. Contrarily, the private well results depict widespread, low-level NO3-concentrations. This evidence supports that in addition to downward transport, there is also a significant outward transport of groundwater NO3- in the drinking water aquifer to areas outside the range of sources. Results indicate that the deeper aquifers are potentially acting as a reservoir that is not only deeper, but also covers a larger geographical area, than the reservoir formed by the shallow aquifers. Results are of interest to agencies that regulate surface water and drinking water sources impacted by the effects of

  6. Procedures for the collection and preservation of groundwater and surface water samples and for the installation of monitoring wells

    International Nuclear Information System (INIS)

    Korte, N.; Kearl, P.

    1984-01-01

    Proper sampling procedures are essential for a successful water-quality monitoring program. It must be emphasized, however, that it is impossible to maintain absolutely in-situ conditions when collecting and preserving a water sample, whether from a flowing stream or an aquifer. Consequently, the most that can reasonably be expected is to collect a best possible sample with minimal disturbance. This document describes procedures for installing monitoring wells and for collecting samples of surface water and groundwater. The discussion of monitoring wells includes mention of multilevel sampling and a general overview of vadose-zone monitoring. Guidelines for well installation are presented in detail. The discussion of water-sample collection contains evaluations of sampling pumps, filtration equipment, and sample containers. Sample-preservation techniques, as published by several government and private sources, are reviewed. Finally, step-by-step procedures for collection of water samples are provided; these procedures address such considerations as necessary equipment, field operations, and written documentation. Separate procedures are also included for the collection of samples for determination of sulfide and for reactive aluminum. The report concludes with a brief discussion of adverse sampling, conditions that may significantly affect the quality of the data. Appendix A presents a rationale for the development and use of statistical considerations in water sampling to ensure a more complete water quality monitoring program. 51 references, 9 figures, 4 tables

  7. Hydrogeology and groundwater quality at monitoring wells installed for the Tunnel and Reservoir Plan System and nearby water-supply wells, Cook County, Illinois, 1995–2013

    Science.gov (United States)

    Kay, Robert T.

    2016-04-04

    Groundwater-quality data collected from 1995 through 2013 from 106 monitoring wells open to the base of the Silurian aquifer surrounding the Tunnel and Reservoir Plan (TARP) System in Cook County, Illinois, were analyzed by the U.S. Geological Survey, in cooperation with the Metropolitan Water Reclamation District of Greater Chicago, to assess the efficacy of the monitoring network and the effects of water movement from the tunnel system to the surrounding aquifer. Groundwater from the Silurian aquifer typically drains to the tunnel system so that analyte concentrations in most of the samples from most of the monitoring wells primarily reflect the concentration of the analyte in the nearby Silurian aquifer. Water quality in the Silurian aquifer is spatially variable because of a variety of natural and non-TARP anthropogenic processes. Therefore, the trends in analyte values at a given well from 1995 through 2013 are primarily a reflection of the spatial variation in the value of the analyte in groundwater within that part of the Silurian aquifer draining to the tunnels. Intermittent drainage of combined sewer flow from the tunnel system to the Silurian aquifer when flow in the tunnel systemis greater than 80 million gallons per day may affect water quality in some nearby monitoring wells. Intermittent drainage of combined sewer flow from the tunnel system to the Silurian aquifer appears to affect the values of electrical conductivity, hardness, sulfate, chloride, dissolved organic carbon, ammonia, and fecal coliform in samples from many wells but typically during less than 5 percent of the sampling events. Drainage of combined sewer flow into the aquifer is most prevalent in the downstream parts of the tunnel systems because of the hydraulic pressures elevated above background values and long residence time of combined sewer flow in those areas. Elevated values of the analytes emplaced during intermittent migration of combined sewer flow into the Silurian aquifer

  8. Soil washing of chromium- and cadmium-contaminated sludge using acids and ethylenediaminetetra acetic acid chelating agent.

    Science.gov (United States)

    Gitipour, Saeid; Ahmadi, Soheil; Madadian, Edris; Ardestani, Mojtaba

    2016-01-01

    In this research, the effect of soil washing in the removal of chromium- and cadmium-contaminated sludge samples collected from Pond 2 of the Tehran Oil Refinery was investigated. These metals are considered as hazardous substances for human health and the environment. The carcinogenicity of chromate dust has been established for a long time. Cadmium is also a potential environmental toxicant. This study was carried out by collecting sludge samples from different locations in Pond 2. Soil washing was conducted to treat the samples. Chemical agents, such as acetic acid, ethylenediaminetetra acetic acid (EDTA) and hydrochloric acid, were used as washing solutions to remove chromium and cadmium from sludge samples. The results of this study indicated that the highest removal efficiencies from the sludge samples were achieved using a 0.3 M HCl solution with 82.69% and 74.47% for chromium and cadmium, respectively. EDTA (0.1 M) in the best condition extracted 66.81% of cadmium and 72.52% of chromium from the sludges. The lowest efficiency values for the samples, however, were achieved using 3 M acetic acid with 41.7% and 46.96% removals for cadmium and chromium, respectively. The analysis of washed sludge indicated that the heavy metals removal decreased in the order of 3 M acetic acid < 0.1 M EDTA<0.3 M HCl, thus hydrochloric acid appears to offer a greater potential as a washing agent in remediating the sludge samples.

  9. Washing-free heterogeneous immunosensor using proximity-dependent electron mediation between an enzyme label and an electrode.

    Science.gov (United States)

    Dutta, Gorachand; Kim, Sinyoung; Park, Seonhwa; Yang, Haesik

    2014-05-06

    Washing processes, essential in most heterogeneous labeled assays, have been a big hurdle in simplifying the detection procedure and reducing assay time. Nevertheless, less attention has been paid to washing-free heterogeneous labeled assays. We report a purely washing-free immunosensor that allows fast, sensitive, and single-step detection of prostate-specific antigen in serum with low interference. Proximity-dependent electron mediation of ferrocenemethanol (Fc) between an indium-tin oxide (ITO) electrode and a glucose-oxidase (GOx) label allows us to discriminate between a bound and an unbound label: a bound label offers faster electron mediation than an unbound one. The electrooxidation of Fc at a low applied potential (0.13 V vs Ag/AgCl) and a low electrocatalytic ITO electrode and the oxidation of l-ascorbic acid by l-ascorbate oxidase minimize the effect of the interfering species. With a high concentration of glucose (200 mM), the signal and background levels are hardly dependent on the glucose-concentration variation in the sample. The washing-free immunosensor can detect a concentration of ca. 1 pg/mL for mouse IgG in phosphate-buffered saline and a concentration of ca. 10 pg/mL for prostate-specific antigen spiked in female serum after an incubation period of 10 min. The concentrations measured with actual clinical serum samples are in good agreement with the concentrations measured with a commercial instrument, which renders the washing-free heterogeneous immunosensor appealing for practical use.

  10. Effect of water-washing on the co-removal of chlorine and heavy metals in air pollution control residue from MSW incineration.

    Science.gov (United States)

    Yang, Zhenzhou; Tian, Sicong; Ji, Ru; Liu, Lili; Wang, Xidong; Zhang, Zuotai

    2017-10-01

    The present study systemically investigated the effect of a water-washing process on the removal of harmful chlorides, sulfates, and heavy metals in the air pollution control (APC) residue from municipal solid wastes incineration (MSWI), for sake of a better reuse and disposal of this kind of waste. In addition, the kinetic study was conducted to reveal the releasing mechanism of relevant element in the residue. The results show that, over 70wt.% of chlorides and nearly 25wt.% of sulfates in the residue could be removed by water washing. Based on an economical consideration, the optimal operation conditions for water washing of APC residue was at liquid/solid (L/S) ratio of 3mL:1g and extracting time of 5min. As expected, the concentrations of Co, Cr, Fe, Ni, V and Cu in the washing effluent increased with time during the washing process. However, the extracting regime differs among different heavy metals. The concentrations of Ba and Mn increased firstly but declined afterwards, and concentrations of Pb and Zn gradually declined while Cd and As kept constant with the increase of extracting time. It is worth mentioning that the bubbling of CO 2 into the washing effluent is promisingly effective for a further removal of Pb, Cu and Zn. Furthermore, kinetic study of the water washing process reveals that the extracting of heavy metals during water washing follows a second-order model. Copyright © 2017 Elsevier Ltd. All rights reserved.

  11. Efficacy of Citrilow® and Cecure® spray wash on the prevalence of aerobic and enterobacteriaceae/gram negative enteric bacilli and cattle hide quality

    Science.gov (United States)

    Bacterial cross-contamination from the haired outer surface of cattle to the inner meat as well as hide quality deterioration from bacteria are hygienic problems for meat and hide processing facilities. This study investigated spray wash treatments independently with two antimicrobials used in the ...

  12. Assessing the effect of sodium dichloroisocyanurate concentration on transfer of Salmonella enterica serotype Typhimurium in wash water for production of minimally processed iceberg lettuce (Lactuca sativa L.).

    Science.gov (United States)

    Maffei, D F; Sant'Ana, A S; Monteiro, G; Schaffner, D W; Franco, B D G M

    2016-06-01

    This study evaluated the impact of sodium dichloroisocyanurate (5, 10, 20, 30, 40, 50 and 250 mg l(-1) ) in wash water on transfer of Salmonella Typhimurium from contaminated lettuce to wash water and then to other noncontaminated lettuces washed sequentially in the same water. Experiments were designed mimicking the conditions commonly seen in minimally processed vegetable (MPV) processing plants in Brazil. The scenarios were as follows: (1) Washing one inoculated lettuce portion in nonchlorinated water, followed by washing 10 noninoculated portions sequentially. (2) Washing one inoculated lettuce portion in chlorinated water followed by washing five noninoculated portions sequentially. (3) Washing five inoculated lettuce portions in chlorinated water sequentially, followed by washing five noninoculated portions sequentially. (4) Washing five noninoculated lettuce portions in chlorinated water sequentially, followed by washing five inoculated portions sequentially and then by washing five noninoculated portions sequentially in the same water. Salm. Typhimurium transfer from inoculated lettuce to wash water and further dissemination to noninoculated lettuces occurred when nonchlorinated water was used (scenario 1). When chlorinated water was used (scenarios 2, 3 and 4), no measurable Salm. Typhimurium transfer occurred if the sanitizer was ≥10 mg l(-1) . Use of sanitizers in correct concentrations is important to minimize the risk of microbial transfer during MPV washing. In this study, the impact of sodium dichloroisocyanurate in the wash water on transfer of Salmonella Typhimurium from inoculated lettuce to wash water and then to other noninoculated lettuces washed sequentially in the same water was evaluated. The use of chlorinated water, at concentration above 10 mg l(-1) , effectively prevented Salm. Typhimurium transfer under several different washing scenarios. Conversely, when nonchlorinated water was used, Salm. Typhimurium transfer occurred in

  13. Challenges and Opportunities for Mainstreaming Climate Change Adaptation into WaSH Development Planning in Ghana

    Directory of Open Access Journals (Sweden)

    Salley Alhassan

    2017-07-01

    Full Text Available Climate change threatens water, sanitation and hygiene (WaSH facilities and services, as these are intimately linked to the water cycle and are vulnerable to changes in the quantity and quality of available water resources. Floods and droughts, which pollute and reduce water delivery respectively, have now become a perennial issue to deal with in the northern regions of Ghana. This study aimed to assess the degree to which climate change adaptation measures are mainstreamed into the water, sanitation and hygiene (WaSH development planning process in Ghana. Stakeholders from government and non-government agencies were interviewed to gain perspectives on the threat of climate change, the inclusion of climate change in WaSH planning and the barriers preventing mainstreaming. Despite awareness of climate change, adaptation measures have not been considered, and the immediate WaSH needs remain the priority. Overall, stakeholders felt the adaptive capacity of the Municipality was low and that mainstreaming has not yet occurred. Despite the lack of progress, there are great opportunities for mainstreaming climate change adaptation into planning through increasing awareness and capacity, legislative and institutional changes and the development of participatory systems to provide early warning systems and disaster risk analyses that will inform future planning.

  14. The Effect of Washing and Peeling on Reduction of Dithiocarbamates Residues in Cucumber and Tomato

    Directory of Open Access Journals (Sweden)

    Mohammad Reza Mehrasebi

    2016-03-01

    Full Text Available Background: Dithiocarbamates, the main group of fungicides, are used to control about 400 pathogens in more than 70 crops. These pesticides are widely applied to crops including potato, cereal, apple, pear and leafy vegetables throughout the world since 1960. From the late 1980s, using these fungicides has caused much debate among regulators about their long-term effects on consumers and occupational users. Method: In this study the residues of Dithiocarbamates in cucumber and tomato using the colorimetric method (Keppel method was measured. Respectively 80 and 45 samples of greenhouse cucumber and tomato were collected from Zanjan vegetables center in autumns and winter 2013. The samples were analyzed in 4 treatments of: unwashed, washing with water, washing whit detergent and peeling. Result: The results showed that the average concentration of Dithiocarbamates residues in unwashed greenhouse cucumber and tomatoes were 384.5 µg/kg and 65 µg/kg respectively. 35% and 5% of unwashed and water washed cucumber and tomato samples (respectively had higher Dithiocarbamates residue than MRL recommended by Institute of Standards and Industrial Research of Iran (0.5mg/kg. Conclusion: The treatments of washing and peeling had significant effect on the reduction of Dithiocarbamates residues in the all samples.

  15. Challenges and Opportunities for Mainstreaming Climate Change Adaptation into WaSH Development Planning in Ghana.

    Science.gov (United States)

    Alhassan, Salley; Hadwen, Wade L

    2017-07-10

    Climate change threatens water, sanitation and hygiene (WaSH) facilities and services, as these are intimately linked to the water cycle and are vulnerable to changes in the quantity and quality of available water resources. Floods and droughts, which pollute and reduce water delivery respectively, have now become a perennial issue to deal with in the northern regions of Ghana. This study aimed to assess the degree to which climate change adaptation measures are mainstreamed into the water, sanitation and hygiene (WaSH) development planning process in Ghana. Stakeholders from government and non-government agencies were interviewed to gain perspectives on the threat of climate change, the inclusion of climate change in WaSH planning and the barriers preventing mainstreaming. Despite awareness of climate change, adaptation measures have not been considered, and the immediate WaSH needs remain the priority. Overall, stakeholders felt the adaptive capacity of the Municipality was low and that mainstreaming has not yet occurred. Despite the lack of progress, there are great opportunities for mainstreaming climate change adaptation into planning through increasing awareness and capacity, legislative and institutional changes and the development of participatory systems to provide early warning systems and disaster risk analyses that will inform future planning.

  16. Effect of washing on the plasma membrane and on stress reactions of cultured rose cells

    International Nuclear Information System (INIS)

    Qian, Y.C.; Nguyen, T.; Murphy, T.M.

    1993-01-01

    Cultured cells of Rosa damascena have been used as a model for studies of responses of plant cells to various stresses, including UV radiation, protein-synthesis inhibitors, and elicitors from pathogens. Many of the responses involve reactions at the plasma membrane: efflux of K + , changes in the acid balance between cytoplasm and external medium, synthesis of H 2 O 2 , and inhibition of ferricyanide reduction. In previous studies, the cells have typically been washed with a solution of low ionic strength. We now show that this washing procedure results in changes in the protein composition of the plasma membrane, in the labeling of the proteins in the plasma membrane, and in the specific activity of ATPase in purified plasma membrane vesicles. Also, compared to the unwashed cells, the washed cells show less net K + efflux after UV-C and Phytophthora elicitor treatments; more synthesis of H 2 O 2 after UV-C and a pattern of accumulation of H 2 O 2 after elicitor treatment that shows a delayed but higher peak; and more inhibition of ferricyanide reduction after UV-C, but not after elicitor treatment. The results suggest that washing has differential effects on the mechanisms by which cultured plant cells perceive or respond to two stresses, UV-C and elicitor

  17. Influence of the washing program on the blood processing performance of a continuous autotransfusion device.

    Science.gov (United States)

    Yoon, Chiyul; Noh, Seungwoo; Lee, Jung Chan; Ko, Sung Ho; Ahn, Wonsik; Kim, Hee Chan

    2014-03-01

    The continuous autotransfusion system has been widely used in surgical operations. It is known that if oil is added to blood, and this mixture is then processed by an autotransfusion device, the added oil is removed and reinfusion of fat is prevented by the device. However, there is no detailed report on the influence of the particular washing program selected on the levels of blood components including blood fat after continuous autotransfusion using such a system. Fresh bovine blood samples were processed by a commercial continuous autotransfusion device using the "emergency," "quality," and "high-quality" programs, applied in random order. Complete blood count (CBC) and serum chemistry were analyzed to determine how the blood processing performance of the device changes with the washing program applied. There was no significant difference in the CBC results obtained with the three washing programs. Although all of the blood lipids in the processed blood were decreased compared to those in the blood before processing, the levels of triglyceride, phospholipid, and total cholesterol after processing via the emergency program were significantly higher than those present after processing via the quality and high-quality programs. Although the continuous autotransfusion device provided consistent hematocrit quality, the levels of some blood lipid components showed significant differences among the washing programs.

  18. Appraisal of the efficacy of washing the surfaces in the slaughter premises by means of bacteria labelled with /sup 32/P

    Energy Technology Data Exchange (ETDEWEB)

    Fiszer, W; Zabielski, J; Mroz, J [Wyzsza Szkola Rolnicza, Poznan (Poland)

    1975-01-01

    There were carried out some experiments to appraise the efficacy of washing different surfaces used in meat industry (ceramics, polished steel, polished aluminium, scratched aluminium, unpolished steel, scratched steel, beech wood, wavy polystyrene and smoth polystyrene) by the use of Bacillus subtilis labelled with /sup 32/P. It was found that beech wood proved to be the most resistant material to wash up and therefore should not be used in meat industry. The effect of washing K is the function of unevenness Ra. That dependence can be expressed with the formula: K=3.0919-0.2361 Ra. A way of washing plays an important role and the use of a scrubbing-brush increased the efficacy of washing from 2 to 8 times. The technique applied appeared very useful to perform such studies.

  19. The appraisal of the efficacy of washing the surfaces in the slaughter premises by means of bacteria labelled with 32P

    International Nuclear Information System (INIS)

    Fiszer, W.; Zabielski, J.; Mroz, J.

    1975-01-01

    There were carried out some experiments to appraise the efficacy of washing different surfaces used in meat industry (ceramics, polished steel, polished aluminium, scratched aluminium, unpolished steel, scratched steel, beech wood, wavy polystyrene and smoth polystyrene) by the use of Bacillus subtilis labelled with 32 P. It was found that beech wood proved to be the most resistant material to wash up and therefore should not be used in meat industry. The effect of washing K is the function of unevenness Ra. That dependence can be expressed with the formula: K=3.0919-0.2361 Ra. A way of washing plays an important role and the use of a scrubbing-brush increased the efficacy of washing from 2 to 8 times. The technique applied appeared very useful to perform such studies. (author)

  20. A reliable procedure for decontamination before thawing of human specimens cryostored in liquid nitrogen: three washes with sterile liquid nitrogen (SLN2).

    Science.gov (United States)

    Parmegiani, Lodovico; Accorsi, Antonio; Bernardi, Silvia; Arnone, Alessandra; Cognigni, Graciela Estela; Filicori, Marco

    2012-10-01

    To report a washing procedure, to be performed as frozen specimens are taken out of cryobanks, to minimize the risk of hypothetical culture contamination during thawing. Basic research. Private assisted reproduction center. Two batches of liquid nitrogen (LN(2)) were experimentally contaminated, one with bacteria (Pseudomonas aeruginosa, Escherichia coli, Stenotrophomonas maltophilia) and the other with fungi (Aspergillus niger). Two hundred thirty-two of the most common human gamete/embryo vitrification carriers (Cryotop, Cryoleaf, Cryopette) were immersed in the contaminated LN(2) (117 in the bacteria and 25 in the fungi-contaminated LN(2)). The carriers were tested microbiologically, one group without washing (control) and the other after three subsequent washings in certified ultraviolet sterile liquid nitrogen (SLN(2)). The carriers were randomly allocated to the "three-wash procedure" (three-wash group, 142 carriers) or "no-wash" (control group, 90 carriers) using a specific software tool. Assessment of microorganism growth. In the no-wash control group, 78.6% of the carriers were contaminated by the bacteria and 100% by the fungi. No carriers were found to be contaminated, either by bacteria or fungi, after the three-wash procedure. The three-wash procedure with SLN(2) produced an efficient decontamination of carriers in extreme experimental conditions. For this reason, this procedure could be routinely performed in IVF laboratories for safe thawing of human specimens that are cryostored in nonhermetical cryocontainers, particularly in the case of open or single-straw closed vitrification systems. Copyright © 2012 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.

  1. Design and Implementation of Control and Monitoring Systems Based on HMI-PLC for Potable Water Well

    Directory of Open Access Journals (Sweden)

    Quezada-Quezada José Carlos

    2014-01-01

    Full Text Available This project reports on the design and implementation in a workbench of a control and monitoring system of the discharge of water of a well. Graphic User's Interfaces (GUI are designed for interaction with the operator. The Human Machine Interface (HMI was implement in proprietor software and it contemplates the rules for control and monitoring of the conditions of the system for the operator, the HMI is also interconnected a Programmable Logic Controller (PLC where the rules of protection of the process are implemented in Ladder Diagram (LD.

  2. 7 CFR 57.801 - Nest run or washed ungraded eggs.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Nest run or washed ungraded eggs. 57.801 Section 57... AND STANDARDS UNDER THE AGRICULTURAL MARKETING ACT OF 1946 AND THE EGG PRODUCTS INSPECTION ACT (CONTINUED) INSPECTION OF EGGS (EGG PRODUCTS INSPECTION ACT) Regulations Governing the Inspection of Eggs...

  3. Natural attenuation of NDMA precursors in an urban, wastewater-dominated wash.

    Science.gov (United States)

    Woods, Gwen C; Dickenson, Eric R V

    2016-02-01

    N-Nitrosodimethylamine (NDMA) is a disinfection by-product (DBP) that is potentially carcinogenic and has been found to occur in drinking water treatment systems impacted with treated wastewater. A major gap in NDMA research is an understanding of the persistence of wastewater-derived precursors within the natural environment. This research sought to fill this knowledge gap by surveying NDMA precursors across the length of a wastewater effluent-dominated wash. Significant precursor reduction (17%) was found to occur from introduction into the wash to a point 9 h downstream. This reduction translates into a half-life of roughly 32 h for bulk NDMA precursors. Further laboratory experiments examining rates of photolysis, biodegradation and loss to sediments, illustrated that both photolytic and biological degradation were effective removal mechanisms for NDMA precursors. Loss to sediments that were acquired from the wash did not appear to reduce NDMA precursors in the water column, although a control conducted with DI water provided evidence that significant NDMA precursors could be released from autoclaved sediments (suggesting that sorption does occur). Microbial experiments revealed that microbes associated with sediments were much more effective at degrading precursors than microbes within the water column. Overall, this study demonstrated that natural processes are capable of attenuating NDMA precursors relatively quickly within the environment, and that utilities might benefit from maximizing source water residency time in the environment, prior to introduction into treatment plants. Copyright © 2015 Elsevier Ltd. All rights reserved.

  4. Drawing a line in the sand: Effectiveness of off-highway vehicle management in California's Sonoran desert

    Science.gov (United States)

    Custer, Nathan; Defalco, Lesley A.; Nussear, Kenneth E.; Esque, Todd C.

    2017-01-01

    Public land policies manage multiple uses while striving to protect vulnerable plant and wildlife habitats from degradation; yet the effectiveness of such policies are infrequently evaluated, particularly for remote landscapes that are difficult to monitor. We assessed the use and impacts of recreational vehicles on Mojave Desert washes (intermittent streams) in the Chemehuevi Desert Wildlife Management Area (DWMA) of southern California. Wash zones designated as open and closed to off-highway vehicle (OHV) activity were designed in part to protect Mojave desert tortoise (Gopherus agassizii) habitat while allowing recreation in designated areas. OHV tracks were monitored in washes located near access roads during winter and early spring holidays – when recreation is typically high – and at randomly dispersed locations away from roads. Washes near access roads had fewer vehicle tracks within closed than open zones; further away from roads, OHV tracks were infrequent and their occurrence was not different between wash designations. Washes were in better condition in closed zones following major holidays as indicated by less vegetation damage, presence of trash, and wash bank damage. Furthermore, the frequency of washes with live tortoises and their sign was marginally greater in closed than open wash zones. Collectively, these results suggest that low impacts to habitats in designated closed wash zones reflect public compliance with federal OHV policy and regulations in the Chemehuevi DWMA during our study. Future monitoring to contrast wash use and impacts during other seasons as well as in other DWMAs will elucidate spatial and temporal patterns of recreation in these important conservation areas.

  5. Investigation of Rheological Impacts on Sludge Batch 3 as Insoluble Solids and Wash Endpoints are Adjusted

    International Nuclear Information System (INIS)

    Fellinger, T. L.

    2005-01-01

    The Defense Waste Processing Facility (DWPF) is currently processing and immobilizing radioactive sludge slurry into a durable borosilicate glass. The DWPF has already processed three sludge batches (Sludge Batch 1A, Sludge Batch 1B, and Sludge Batch 2) and is currently processing the fourth sludge batch (Sludge Batch 3). A sludge batch is defined as a single tank of sludge slurry or a combination of sludge slurries from different tanks that has been or will be qualified before being transferred to DWPF. As a part of the Sludge Batch 3 (SB3) qualification task, rheology measurements of the sludge slurry were requested at different insoluble solids loadings. These measurements were requested in order to gain insight into potential processing problems that may occur as the insoluble solids are adjusted up or down (by concentration or dilution) during the process. As a part of this study, a portion of the ''as received'' SB3 sample was washed with inhibited water (0.015 M NaOH and 0.015 M NaNO2) to target 0.5M Na versus a measured 1M Na in the supernate. The purpose of the ''washing'' step was to allow a comparison of the SB3 rheological data to the rheological data collected for Sludge Batch 2 (SB2) and to determine if there was a dependence of the yield stress and consistency as a function of washing. The ''as received'' SB3 rheology data was also compared to SB3 simulants prepared by the Simulant Development Program in order to provide guidance for selecting a simulant that is more representative of the rheological properties of the radioactive sludge slurry. A summary of the observations, conclusions are: (1) The yield stress and plastic viscosity increased as the weight percent insoluble solids were increased for the ''as received'' and ''washed'' SB3 samples, at a fixed pH. (2) For the same insoluble solids loading, the yield stress for the SB2 sample is approximately a factor of three higher than the ''as received'' SB3 sample. There also appears to be small

  6. Knowledge and practices regarding water, sanitation and hygiene (WASH) among mothers of under-fives in Mawabeni, Umzingwane District of Zimbabwe

    Science.gov (United States)

    Demberere, Tendai; Chidziya, Tayedza; Ncozana, Tatenda; Manyeruke, Norman

    2016-04-01

    The research study sought to assess knowledge and practices of mothers of under-fives regarding WASH in Mawabeni communal area in Zimbabwe. Focus group discussions, interviews, questionnaires and observation checklists were used to collect data. Data was analysed by developing specific themes related to the objectives and then frequencies were computed in Microsoft Excel. The mean score on WASH knowledge for the mothers of under-fives according to the Knowledge Index was 1. Knowledge regarding safety of water from different sources was generally poor with 70% of the mothers regarding water from surface sources to be safe to drink without treatment. Use of wide mouthed containers without lids was also common in the study area. However, no relationship was established between the type of water container used and the socio-demographic characteristics of the respondents. Knowledge regarding the importance of ablutions was generally good as highlighted by 78% of the mothers who regarded latrines as being important in prevention and control of diseases as well as for hygiene purposes. However, latrine ownership was noted to be related to the income level of the household (p sanitation practices on WASH among mothers of under-fives in Mawabeni were both poor and this could be a contributory factor to the high incidence of diarrheal diseases for under-fives in the area.

  7. SITE CHARACTERIZATION AND MONITORING DATA FROM THE AREA 5 PILOT WELLS

    International Nuclear Information System (INIS)

    2005-01-01

    .5 meters in each borehole, and a nearly zero potential gradient throughout the remaining portion of the vadose zone. These hydrologic condition data and hydrologic property data indicate that little net downward liquid flow is occurring (if any) through the thick vadose zone. Conversely, gas flow by diffusion, and possibly by advection, may be an important transport mechanism. Environmental tracer measurements made on water extracted from geologic samples suggest that water vapor in the upper portion of the vadose zone is moving upward in response to evaporative demand of the present arid climate. Preliminary water quality data indicate that the key hazardous and radioactive constituents do not exceed appropriate standards. Monitoring instruments and equipment were installed in each pilot well for making in-situ measurements of key hydrologic and pneumatic parameters and to monitor change in these parameters over time

  8. Effect of face washing with soap and water and cleaning with antiseptics on upper-lid bacteria of surgical eye patients.

    Science.gov (United States)

    Bekibele, Charles O; Kehinde, Aderemi O; Ajayi, Benedictus G K

    2010-12-01

    To determine the effect of face washing with soap and water and cleaning with povidone iodine and cetrimide/chlorhexidine gluconate (Savlon) on upper-lid bacteria. Prospective, nonrandomized clinical trial. Eighty patients attending the Eye Clinic, University College Hospital, Ibadan, Nigeria. Eighty patients assigned to 4 groups had swabs of the upper eyelid skin taken before and after face wash with soap and water, and cleansing with Savlon and 5% povidone iodine. Specimens were cultured and Gram stained. Bacterial counts were carried out using standard techniques. Face washing with soap and water increased the proportion of patients with bacterial isolates from 80.0% to 87.5%. The average colony count increased from 187.1 to 318.5 colony units per mL (p = 0.02). Application of 5% povidone iodine without face washing with soap and water reduced the proportion of patients with bacterial isolates from 82.6% (mean count 196.5) to 28.6% (mean count 34.1)(p = 0.001); in comparison, the application of 5% povidone iodine after face washing with soap and water reduced the proportion from 71.4% (mean count 133.9) to 40.0% (mean count 69.0)(p = 0.01). Application of Savlon without face washing with soap and water reduced the proportion of patients with bacterial isolates from 100% (mean count 310.9) to 41.2% (mean count 19.8)(p = 0.004) compared with the application after face washing, which reduced the proportion from 89.5% (mean count 240.3) to 41.2% (mean count 82.9)(p = 0.02). Both povidone and Savlon are effective in reducing periocular bacteria in an African setting. Prior face washing with soap and water had no added benefit in reducing bacterial colony count.

  9. Washable and Reliable Textile Electrodes Embedded into Underwear Fabric for Electrocardiography (ECG Monitoring

    Directory of Open Access Journals (Sweden)

    Amale Ankhili

    2018-02-01

    Full Text Available A medical quality electrocardiogram (ECG signal is necessary for permanent monitoring, and an accurate heart examination can be obtained from instrumented underwear only if it is equipped with high-quality, flexible, textile-based electrodes guaranteeing low contact resistance with the skin. The main objective of this article is to develop reliable and washable ECG monitoring underwear able to record and wirelessly send an ECG signal in real time to a smart phone and further to a cloud. The article focuses on textile electrode design and production guaranteeing optimal contact impedance. Therefore, different types of textile fabrics were coated with modified poly(3,4-ethylenedioxythiophene:poly(styrenesulfonate (PEDOT:PSS in order to develop and manufacture reliable and washable textile electrodes assembled to female underwear (bras, by sewing using commercially available conductive yarns. Washability tests of connected underwear containing textile electrodes and conductive threads were carried out up to 50 washing cycles. The influence of standardized washing cycles on the quality of ECG signals and the electrical properties of the textile electrodes were investigated and characterized.

  10. Washable and Reliable Textile Electrodes Embedded into Underwear Fabric for Electrocardiography (ECG) Monitoring.

    Science.gov (United States)

    Ankhili, Amale; Tao, Xuyuan; Cochrane, Cédric; Coulon, David; Koncar, Vladan

    2018-02-07

    A medical quality electrocardiogram (ECG) signal is necessary for permanent monitoring, and an accurate heart examination can be obtained from instrumented underwear only if it is equipped with high-quality, flexible, textile-based electrodes guaranteeing low contact resistance with the skin. The main objective of this article is to develop reliable and washable ECG monitoring underwear able to record and wirelessly send an ECG signal in real time to a smart phone and further to a cloud. The article focuses on textile electrode design and production guaranteeing optimal contact impedance. Therefore, different types of textile fabrics were coated with modified poly(3,4-ethylenedioxythiophene):poly(styrenesulfonate) (PEDOT:PSS) in order to develop and manufacture reliable and washable textile electrodes assembled to female underwear (bras), by sewing using commercially available conductive yarns. Washability tests of connected underwear containing textile electrodes and conductive threads were carried out up to 50 washing cycles. The influence of standardized washing cycles on the quality of ECG signals and the electrical properties of the textile electrodes were investigated and characterized.

  11. Preservation Method and Phosphate Buffered Saline Washing Affect the Acute Myeloid Leukemia Proteome

    Directory of Open Access Journals (Sweden)

    Rebecca Wangen

    2018-01-01

    Full Text Available Acute myeloid leukemia (AML primary cells can be isolated from peripheral blood, suspended with media containing bovine serum and cryoprotectant, and stored in liquid nitrogen before being processed for proteomic analysis by mass spectrometry (MS. The presence of bovine serum and human blood proteins in AML samples can hamper the identifications of proteins, and thereby reduce the proteome coverage of the study. Herein, we have established the effect of phosphate buffered saline (PBS washing on AML patient samples stored in media. Although PBS washes effectively removed serum and blood contaminants, the saline wash resulted in cell burst and remarkable protein material loss. We also compared different methods to preserve the AML proteome from THP-1 and Molm-13 cell lines before MS analysis: (1 stored in media containing bovine serum and dimethyl sulfoxide (DMSO; (2 stored as dried cell pellets; and (3 stored as cell lysates in 4% sodium dodecyl sulfate (SDS. MS analysis of differently preserved AML cell samples shows that preservation with DMSO produce a high number of fragile cells that will burst during freezing and thawing. Our studies encourage the use of alternative preservation methods for future MS analysis of the AML proteome.

  12. Application of washed MSWI fly ash in cement composites: long-term environmental impacts.

    Science.gov (United States)

    Yang, Zhenzhou; Tian, Sicong; Liu, Lili; Wang, Xidong; Zhang, Zuotai

    2018-04-01

    In the present study, long-term environmental impacts of compact and ground cement composites, in which 30 wt.% of cement was replaced by washed municipal solid wastes incineration (MSWI) fly ash, were investigated for use in building industry. Consecutive leaching tests over a time span of 180 days were performed in acid water, deionized water, and saline water, respectively, with the accumulative concentration of different elements determined in the leachate. Different leaching behaviors are observed among different potential toxic elements (PTEs). For instance, higher concentrations of V in the leachate were observed from the compact cement composites than those from the ground ones. The concentration of Ba in the leachate increased with the decrease of particle size of the cement composites, and an initial increase in the leaching efficiency of Sn was followed by a clear decline with the leaching time. In addition, kinetic study revealed that the leaching behaviors of potential toxic elements follow a second-order model. The results demonstrated that the addition of washed MSWI fly ash into cement can contribute to the attrition resistance, indicating that the washed MSWI fly ash could be a promising alternative for cement as supplementary building materials.

  13. Biological monitors of air pollution

    International Nuclear Information System (INIS)

    Kucera, J.

    1994-01-01

    Direct biological monitoring of air pollution was introduced about 30 years ago. Although still under development, the application of biological monitors, or indicators, may provide important information on the levels, availability, and pathways of a variety of pollutants including heavy metals and other toxic trace elements in the air. A survey is given of the most frequently used biomonitors, such as herbaceous plants, tree leaves or needles, bryophytes, and lichens, with their possible advantages and/or limitations. In addition to using naturally-occurring biomonitors, a possibility of employing ''transplanted'' species in the study areas, for instance grasses grown in special containers in standard soils or lichens transplanted with their natural substrate to an exposition site, is also mentioned. Several sampling and washing procedures are reported. The important of employing nuclear analytical methods, especially instrumental neutron activation analysis, for multielemental analysis of biomonitors as a pre-requisite for unlocking the information contained in chemical composition of monitor's tissues, such as apportionment of emission sources using multivariate statistical procedures, is also outlined. (author). 32 refs, 2 figs

  14. Membrane processes for the reuse of car washing wastewater

    Directory of Open Access Journals (Sweden)

    Deniz Uçar

    2018-04-01

    Full Text Available This study investigates alternative treatments of car wash effluents. The car wash wastewater was treated by settling, filtration, and membrane filtration processes. During settling, total solid concentration decreased rapidly within the first 2 hours and then remained constant. Chemical oxygen demand (COD and conductivity were decreased by 10% and 4%, respectively. After settling, wastewater was filtered throughout a 100 μm filter. It was found that filtration had a negligible effect on COD removal. Finally, wastewater was filtered by four ultrafiltration membranes of varying molecular weight cutoff (MWCO (1, 5, 10 and 50 kDa and one nanofiltration membrane (NF270, MWCO = 200–400 Da. The permeate COD concentrations varied between 64.5 ± 3.2 and 85.5 ± 4.3 mg L−1 depending on UF pore size. When the NF270 nanofiltration membrane was used, the permeate COD concentration was 8.1 ± 0.4 mg L−1 corresponding to 97% removal. FeCl3 precipitation and activated carbon adsorption techniques were also applied to the retentate and 60–76% COD removals were obtained for activated carbon adsorption and FeCl3 precipitation, respectively.

  15. Quarry detection monitoring wells completion report WP-166

    International Nuclear Information System (INIS)

    1991-09-01

    The purpose of this report is to document the activities undertaken during implementation of Work Package 166, Quarry Detection Monitoring Wells, for the Weldon Spring Site Remedial action project, Weldon Spring, Missouri. The subcontract specifications should be consulted for specific details regarding this work effort. Analytical parameters for soil samples collected for all but one borehole were analyzed for uranium, thorium, cyanide, nitroaromatics, and all Hazardous Substance List parameters including volatiles, semivolatiles, pesticides, polychlorinated biphenyls (PCBs) and metals. No soil samples were collected at other borehole as per specifications. With Z exceptions, uranium results for all boreholes sampled were at background levels. Nitroaromatics and cyanide were not detected in any of the samples collected. Volatile and semivolatile organics were not detected in the soil samples collected from the boreholes, with the exception of common lab contaminants such as methylene chloride, toluene, acetone, and pathalates. All metals results were either within their natural background ranges or below the detection limit of the instrument. PCB's were not detected within any of the boreholes. Pesticides detected (aldrin and methoxychlor) at one borehole near the surface may be attributed to previous spraying of pesticides on the highway right-of-way. In conclusion, the analytical results show that only uranium was detected in significant quantities; all other results were below the detection limit, very near the detection limit, or within natural background ranges. 1 fig

  16. Installation of Groundwater Monitoring Wells TAV-MW15 and TAV-MW16.

    Energy Technology Data Exchange (ETDEWEB)

    Lum, Clinton C. L. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2017-05-01

    This report documents the installation of two groundwater monitoring wells at the Technical Area V Groundwater (TAVG) Area of Concern at Sandia National Laboratories, New Mexico (SNL/NM). SNL/NM is managed and operated by National Technology and Engineering Solutions of Sandia, LLC., a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA- 0003525. Well installation activities were conducted in accordance with the New Mexico Environment Department (NMED) Hazardous Waste Bureau (HWB)-approved work plan Revised Treatability Study Work Plan for In-Situ Bioremediation at the Technical Area-V Groundwater Area of Concern (Work Plan) (SNL/NM March 2016). The Work Plan was approved by NMED HWB prior to the start of field work (NMED May 2016). Project activities were performed from November 2016 through January 2017 by SNL/NM Environmental Restoration (ER) Operations personnel, and the SNL/NM drilling contractor Cascade Drilling LP. Drilling activities began with borehole drilling and sampling on November 30, 2016. Well construction and development fieldwork was completed on January 31, 2017. Land surveys to establish the location coordinates and elevations of the two wells were completed on March 23, 2017, and transmitted to SNL/NM personnel on April 17, 2017.

  17. A comparison of ethanol and methane fermentation of currant-and sultana-washing wastewater

    Energy Technology Data Exchange (ETDEWEB)

    Athanasopoulos, Nikolaos (Patras Univ. (Greece). Dept. of Chemistry)

    1994-01-01

    Wastewater from currant- and sultana-washing processes was successfully treated in an ethanol fermenter at 33[sup o]C; the pH of the wash water was controlled at 2.8; the reducing sugar content was 38.8 g/litre; commercial baker's yeast was used as inoculum at a concentration of 2.5 g/litre; formaldehyde at a concentration of 150 mg/litre was used as antiseptic; the ethanol yield was 70.6% of the theoretical value in 24 h; the COD removal after a single distillation was 84%. The overall economics of ethanol fermentation are very promising compared to methane fermentation. (author)

  18. Experimental study of variations in background radiation and the effect on Nuclear Car Wash sensitivity

    International Nuclear Information System (INIS)

    Church, J; Slaughter, D; Norman, E; Asztalos, S; Biltoft, P

    2007-01-01

    Error rates in a cargo screening system such as the Nuclear Car Wash [1-7] depend on the standard deviation of the background radiation count rate. Because the Nuclear Car Wash is an active interrogation technique, the radiation signal for fissile material must be detected above a background count rate consisting of cosmic, ambient, and neutron-activated radiations. It was suggested previously [1,6] that the Corresponding negative repercussions for the sensitivity of the system were shown. Therefore, to assure the most accurate estimation of the variation, experiments have been performed to quantify components of the actual variance in the background count rate, including variations in generator power, irradiation time, and container contents. The background variance is determined by these experiments to be a factor of 2 smaller than values assumed in previous analyses, resulting in substantially improved projections of system performance for the Nuclear Car Wash

  19. An analysis of the effectiveness of WASH interventions in relation to diarrhoeal diseases in Chipinge district, Zimbabwe

    Science.gov (United States)

    Demberere, T.; Muyambo, M.; Mutengu, S.; Ncozana, T.; Manyeruke, N.

    A study to analyse the effectiveness of WASH interventions in mitigating diarrhoeal diseases in ward 22 of Chipinge district, Manicaland Province was done in 2012. The objectives of the study were to determine the existing WASH interventions in the ward, to assess the KAP on WASH interventions as a mitigation measure against diarrhoeal disease, to analyse the trend of diarrhoea from 2005 to 2011 and to analyse the behaviour change attributed to WASH interventions. Data was collected using interviews, questionnaires, FGDs and observation checklists. Data was analysed using SPSS version 16.0 and qualitative data was analysed by developing themes related to specific objectives. Results showed that WASH interventions were in place in all the villages of ward 22 though they were inadequate. The interventions among others included borehole rehabilitation, latrine construction and Participatory Health and Hygiene Education (PHHE). The cases of diarrhoea were on the increase between 2005 and 2011 despite the various WASH interventions. It was also noted that, although the communities had knowledge on good hygiene practices, economic hardships prevented them from practicing. Behaviour change was also noticed due to an increase in the number of households with hygiene enabling facilities. It was concluded that there is need to provide more water supply and sanitation facilities in the ward. Nurses and EHTs in the ward need to intensify on Health and hygiene education. It was recommended that the duration for PHHE sessions be lengthened and that Village Health Clubs should be formed for sustainability of the health and hygiene component of the interventions. Participation of vulnerable groups such as the disabled, People Living with HIV and AIDS and child headed families should also be encouraged as their participation was seen to be very low, yet their contribution in the society is very critical.

  20. Remediation of multiple heavy metal-contaminated soil through the combination of soil washing and in situ immobilization.

    Science.gov (United States)

    Zhai, Xiuqing; Li, Zhongwu; Huang, Bin; Luo, Ninglin; Huang, Mei; Zhang, Qiu; Zeng, Guangming

    2018-09-01

    The remediation of heavy metal-contaminated soils is a great challenge for global environmental sciences and engineering. To control the ecological risks of heavy metal-contaminated soil more effectively, the present study focused on the combination of soil washing (with FeCl 3 ) and in situ immobilization (with lime, biochar, and black carbon). The results showed that the removal rate of Cd, Pb, Zn, and Cu was 62.9%, 52.1%, 30.0%, and 16.7%, respectively, when washed with FeCl 3 . After the combined remediation (immobilization with 1% (w/w) lime), the contaminated soils showed 36.5%, 73.6%, 70.9%, and 53.4% reductions in the bioavailability of Cd, Cu, Pb, and Zn (extracted with 0.11M acetic acid), respectively, than those of the soils washed with FeCl 3 only. However, the immobilization with 1% (w/w) biochar or 1% (w/w) carbon black after washing exhibited low effects on stabilizing the metals. The differences in effects between the immobilization with lime, biochar, and carbon black indicated that the soil pH had a significant influence on the lability of heavy metals during the combined remediation process. The activity of the soil enzymes (urease, sucrase, and catalase) showed that the addition of all the materials, including lime, biochar, and carbon black, exhibited positive effects on microbial remediation after soil washing. Furthermore, lime was the most effective material, indicating that low soil pH and high acid-soluble metal concentrations might restrain the activity of soil enzymes. Soil pH and nutrition were the major considerations for microbial remediation during the combined remediation. These findings suggest that the combination of soil washing and in situ immobilization is an effective method to amend the soils contaminated with multiple heavy metals. Copyright © 2018 Elsevier B.V. All rights reserved.

  1. The effect of Ebola Virus Disease outbreak on hand washing among secondary school students in Ondo State Nigeria, October, 2014.

    Science.gov (United States)

    Ilesanmi, Olayinka Stephen; Alele, Faith Osaretin

    2015-01-01

    Hand washing with soap and water is one of the cheapest, most effective ways of limiting the spread of Ebola Virus Disease (EVD). Despite its importance the prevalence of hand washing was low before the EVD outbreak in Nigeria. This study aimed at determining the factors associated with improved hand washing practices following the EVD outbreak. A descriptive cross sectional study of 440 students from a secondary school in Owo, Ondo State was done. Data was collected in October 2014 when Nigeria was yet to be declared EVD free. Systematic random sampling was used. A semi-structured, interviewer administered questionnaire was used. Data was analysed with epi info version 7, descriptive statistics were done, Chi square test was used for the assessment of significant associations between proportions. Determinants of good hand washing practices was identified using logistics regression analysis at 5% level of significance. Of 440 respondents, mean age was 13.7±1.9 years. Females were 48.2%. Only 4.6% have never heard of Ebola Virus Disease.Level of hand washing with soap and water improved by62.6%. Significant improvement in hand washing was in 75.8% of those who heard through social media (p Newspaper readers(p schools.

  2. Assessment of spatiotemporal variations in the fluvial wash-load component in the 21st century with regard to GCM climate change scenarios

    International Nuclear Information System (INIS)

    Mouri, Goro

    2015-01-01

    For stream water, in which a relationship exists between wash-load concentration and discharge, an estimate of fine-sediment delivery may be obtained from a traditional fluvial wash-load rating curve. Here, we demonstrate that the remaining wash-load material load can be estimated from a traditional empirical principle on a nationwide scale. The traditional technique was applied to stream water for the whole of Japan. Four typical GCMs were selected from the Coupled Model Intercomparison Project Phase 5 (CMIP5) ensemble to provide the driving fields for the following regional climate models to assess the wash-load component based on rating curves: the Model for Interdisciplinary Research on Climate (MIROC), the Meteorological Research Institute Atmospheric General Circulation Model (MRI-GCM), the Hadley Centre Global Environment Model (HadGEM) and the Geophysical Fluid Dynamics Laboratory (GFDL) climate model. The simulations consisted of an ensemble, including multiple physics configurations and different Representative Concentration Pathways (RCP2.6, RCP4.5 and RCP8.5), which was used to produce monthly datasets for the whole country of Japan. The impacts of future climate changes on fluvial wash load in Japanese stream water were based on the balance of changes in hydrological factors. The annual and seasonal variations of the fluvial wash load were assessed from the result of the ensemble analysis in consideration of the Greenhouse Gas (GHG) emission scenarios. The determined results for the amount of wash load increase range from approximately 20 to 110% in the 2040s, especially along part of the Pacific Ocean and the Sea of Japan regions. In the 2090s, the amount of wash load is projected to increase by more than 50% over the whole of Japan. The assessment indicates that seasonal variation is particularly important because the rainy and typhoon seasons, which include extreme events, are the dominant seasons. Because fluvial wash-load-component turbidity

  3. Assessment of spatiotemporal variations in the fluvial wash-load component in the 21st century with regard to GCM climate change scenarios

    Energy Technology Data Exchange (ETDEWEB)

    Mouri, Goro, E-mail: mouri@rainbow.iis.u-tokyo.ac.jp

    2015-11-15

    For stream water, in which a relationship exists between wash-load concentration and discharge, an estimate of fine-sediment delivery may be obtained from a traditional fluvial wash-load rating curve. Here, we demonstrate that the remaining wash-load material load can be estimated from a traditional empirical principle on a nationwide scale. The traditional technique was applied to stream water for the whole of Japan. Four typical GCMs were selected from the Coupled Model Intercomparison Project Phase 5 (CMIP5) ensemble to provide the driving fields for the following regional climate models to assess the wash-load component based on rating curves: the Model for Interdisciplinary Research on Climate (MIROC), the Meteorological Research Institute Atmospheric General Circulation Model (MRI-GCM), the Hadley Centre Global Environment Model (HadGEM) and the Geophysical Fluid Dynamics Laboratory (GFDL) climate model. The simulations consisted of an ensemble, including multiple physics configurations and different Representative Concentration Pathways (RCP2.6, RCP4.5 and RCP8.5), which was used to produce monthly datasets for the whole country of Japan. The impacts of future climate changes on fluvial wash load in Japanese stream water were based on the balance of changes in hydrological factors. The annual and seasonal variations of the fluvial wash load were assessed from the result of the ensemble analysis in consideration of the Greenhouse Gas (GHG) emission scenarios. The determined results for the amount of wash load increase range from approximately 20 to 110% in the 2040s, especially along part of the Pacific Ocean and the Sea of Japan regions. In the 2090s, the amount of wash load is projected to increase by more than 50% over the whole of Japan. The assessment indicates that seasonal variation is particularly important because the rainy and typhoon seasons, which include extreme events, are the dominant seasons. Because fluvial wash-load-component turbidity

  4. Washed cell salvage in surgical patients: A review and meta-analysis of prospective randomized trials under PRISMA.

    Science.gov (United States)

    Meybohm, Patrick; Choorapoikayil, Suma; Wessels, Anke; Herrmann, Eva; Zacharowski, Kai; Spahn, Donat R

    2016-08-01

    Cell salvage is commonly used as part of a blood conservation strategy. However concerns among clinicians exist about the efficacy of transfusion of washed cell salvage. We performed a meta-analysis of randomized controlled trials in which patients, scheduled for all types of surgery, were randomized to washed cell salvage or to a control group with no cell salvage. Data were independently extracted, risk ratio (RR), and weighted mean differences (WMD) with 95% confidence intervals (CIs) were calculated. Data were pooled using a random effects model. The primary endpoint was the number of patients exposed to allogeneic red blood cell (RBC) transfusion. Out of 1140 search results, a total of 47 trials were included. Overall, the use of washed cell salvage reduced the rate of exposure to allogeneic RBC transfusion by a relative 39% (RR = 0.61; 95% CI 0.57 to 0.65; P platelets, or rate of myocardial infarction and stroke. Washed cell salvage is efficacious in reducing the need for allogeneic RBC transfusion and risk of infection in surgery.

  5. Arsenic bioavailability in soils before and after soil washing: the use of Escherichia coli whole-cell bioreporters.

    Science.gov (United States)

    Yoon, Youngdae; Kang, Yerin; Chae, Yooeun; Kim, Sunghoon; Lee, Youngshim; Jeong, Seung-Woo; An, Youn-Joo

    2016-02-01

    We investigated the quantification of bioavailable arsenic in contaminated soils and evaluation of soil-washing processes in the aspect of bioavailability using a novel bacterial bioreporter developed in present study. The whole-cell bioreporter (WCB) was genetically engineered by fusing the promoter of nik operon from Escherichia coli and green fluorescent protein as a sensing domain and reporter domain. Among eight well-known hazardous heavy metals and metalloid, this system responded specifically to arsenic, thereby inferring association of As(III) with NikR inhibits the repression. Moreover, the response was proportional to the concentration of As(III), thereby it was capable to determine the amount of bioavailable arsenic quantitatively in contaminated soils. The bioavailable portion of arsenic was 5.9 (3.46-10.96) and 0.9 (0.27-1.74) % of total from amended and site soils, respectively, suggesting the bioavailability of arsenic in soils was related to the soil properties and duration of aging. On the other hand, only 1.37 (0.21-2.97) % of total arsenic was extracted into soil solutions and 19.88 (11.86-28.27) % of arsenic in soil solution was bioavailable. This result showed that the soluble arsenic is not all bioavailable and most of bioavailable arsenic in soils is water non-extractable. In addition, the bioavailable arsenic was increased after soil-washing while total amount was decreased, thereby suggesting the soil-washing processes release arsenic associated with soil materials to be bioavailable. Therefore, it would be valuable to have a tool to assess bioavailability and the bioavailability should be taken into consideration for soil remediation plans.

  6. Linde Rectiscol{reg_sign} process. The most economic and experienced wash process for removal of sulfur compounds and CO{sub 2} from gasification gases

    Energy Technology Data Exchange (ETDEWEB)

    Kaballo, H.-P.; Kerestceciogly, U. [Linde AG, Hoellriegelskreuth (Germany). Linde Engineering Division

    2006-07-01

    The Recitsol{reg_sign} wash process is a well-proven process for the removal of H{sub 2}S/COS and CO{sub 2} from coal, asphalt, pitch or oil derived synthesis gas. It is a physical gas wash system using methanol as solvent at operating temperatures below water freezing point, to produce a synthesis gas with less than 0.1 vppm of total sulfur. The CO{sub 2} content can be adjusted in a range from several mol-percent down to a few ppm, as is required by the specified application. Its main advantages are the use of cheap and readily available methanol as solvent, the very flexible process configuration, and rather low utility consumption figures compared with other wash processes, like PEGE based process or chemical washes. A modern concept of a Rectisol{reg_sign} unit is described, to treat shifted and un-shifted gases in just one plant: shifted gas was used for hydrotreating in a refinery. Unshifted gas was used as fuel gas for power generation in an IGCC. CO{sub 2} of the unshifted feed gas was removed only partly, because the remaining CO{sub 2} was fed as inert gas together with the fuel gas to an IGCC. All sulfur compounds of both feed gases were concentrated in one single stream with a high H{sub 2}S concentration. Impurities like NH{sub 3}, HCN or metal carbonyls were eliminated nearly quantitatively. 4 refs., 4 figs., 3 tabs.

  7. Fast pyrolysis of corn stover using ZnCl2: Effect of washing treatment on the furfural yield and solvent extraction of furfural

    International Nuclear Information System (INIS)

    Oh, Seung-Jin; Choi, Gyung-Goo; Kim, Joo-Sik

    2015-01-01

    To produce a bio-oil having a high concentration of furfural, corn stover was fast-pyrolyzed using ZnCl 2 in a fluidized bed reactor at 330–430 °C. The effects of various parameters such as reaction temperature, water- and acid-washing prior to pyrolysis, and ZnCl 2 content on the product and furfural yields were investigated. Moreover, solvent extraction was conducted using toluene at different mass ratios of bio-oil/toluene to recover furfural from the obtained bio-oil. The maximum yield of bio-oil was 59 wt%. The bio-oil mainly comprised acetic acid, α-hydroxyketones, and furfural. The maximum furfural yield was 11.5 wt% when the feed material was water-washed, impregnated with 18.5 wt% ZnCl 2 , and pyrolyzed. Although acid-washing removed alkali and alkaline earth metals much more efficiently than water-washing, water-washing was better than acid-washing for the furfural production. Toluene extraction was very effective to recover furfural from bio-oil. The maximum recovery rate (82%) was achieved at a bio-oil/toluene ratio of 1:4. - Highlights: • Corn stover pretreated and impregnated with ZnCl 2 was successfully pyrolyzed. • Furfural was recovered from bio-oil by extraction using toluene. • Water-washing was better than acid-washing for the furfural production. • The highest furfural yield was 11.5 wt% of the product. • The highest furfural recovery rate was 82%

  8. The influence of sodium-polyacrilic macromolecular chain length to the powder detergents secondary washing performances

    Directory of Open Access Journals (Sweden)

    Milojević Vladimir S.

    2013-01-01

    Full Text Available In order to investigate the influence of sodium-polyacrylate polymer as a co-builder in addition to the carbonate/zeolite builders in detergent builder system, secondary washing performances of powder laundry detergent containing equal percentage of sodium polyacrylate with the different weight average molar mass, Mw, have been examined. The value of the degree of whiteness, elongation at break, and total residue content are the most important secondary washing performances that significantly depend on sodium polyacrylates efficiency used as crystal inhibitors, stabilizers for suspended soil, and agents for soil redisposition prevention on fabric surface. The values of the whiteness and elongation at break for cotton fabrics increase with the increase of average weight molecular mass, Mw, up to the value of 70000 g/mol, while in the case of further increase of weight average molar mass up to the 250000 g/mol value of these characteristics begin to decline. The values of the total residue content after combustion indicate an increase in its content with the increase of weight average molar mass of 3000 to 70000 g/mol, while the highest value has been reached in the sample of detergent containing sodiumpolyacrilic with the weight average molar mass of 250000 g/mol. All detergent samples show no significant dependence of the secondary washing characteristics on the number of washing cycles.

  9. Mercury distribution and lipid oxidation in fish muscle: Effects of washing and isoelectric protein precipitation

    Science.gov (United States)

    Gong, Y.; Krabbenhoft, D.P.; Ren, L.; Egelandsdal, B.; Richards, M.P.

    2011-01-01

    Nearly all the mercury (Hg) in whole muscle from whitefish (Coregonus clupeaformis) and walleye (Sander vitreus) was present as methyl mercury (MeHg). The Hg content in whole muscle from whitefish and walleye was 0.04-0.09 and 0.14-0.81 ppm, respectively. The myofibril fraction contained approximately three-fourths of the Hg in whitefish and walleye whole muscle. The sarcoplasmic protein fraction (e.g., press juice) was the next most abundant source of Hg. Isolated myosin, triacylglycerols, and cellular membranes contained the least Hg. Protein isolates prepared by pH shifting in the presence of citric acid did not decrease Hg levels. Addition of cysteine during washing decreased the Hg content in washed muscle probably through the interaction of the sulfhydryl group in cysteine with MeHg. Primary and secondary lipid oxidation products were lower during 2 ??C storage in isolates prepared by pH shifting compared to those of washed or unwashed mince from whole muscle. This was attributed to removing some of the cellular membranes by pH shifting. Washing the mince accelerated lipid peroxide formation but decreased secondary lipid oxidation products compared to that of the unwashed mince. This suggested that there was a lipid hydroperoxide generating system that was active upon dilution of aqueous antioxidants and pro-oxidants. ?? 2011 American Chemical Society.

  10. Effects of particle size on the morphology and waterand thermo-resistance of washed cottonseed meal-based wood adhesives

    Science.gov (United States)

    Water wash of cottonseed meal is more cost-efficient and environment-friendly than the protein isolation which involves alkaline extraction and acidic precipitation. Thus, water-washed cottonseed meal (WCSM) is more promising as biobased wood adhesives. In this work, we examined the effects of the p...

  11. Title V Operating Permit: QEP Field Services Company - Coyote Wash Compressor Station

    Science.gov (United States)

    Response to public comments and the Title V Operating Permit for the QEP Field Services Company, Coyote Wash Compressor Station, located on the Uintah and Ouray Indian Reservation in Uintah County, Utah.

  12. Distribution and movement of Big Spring spinedace (Lepidomeda mollispinis pratensis) in Condor Canyon, Meadow Valley Wash, Nevada

    Science.gov (United States)

    Jezorek, Ian G.; Connolly, Patrick J.

    2013-01-01

    Big Spring spinedace (Lepidomeda mollispinis pratensis) is a cyprinid whose entire population occurs within a section of Meadow Valley Wash, Nevada. Other spinedace species have suffered population and range declines (one species is extinct). Managers, concerned about the vulnerability of Big Spring spinedace, have considered habitat restoration actions or translocation, but they have lacked data on distribution or habitat use. Our study occurred in an 8.2-km section of Meadow Valley Wash, including about 7.2 km in Condor Canyon and 0.8 km upstream of the canyon. Big Spring spinedace were present upstream of the currently listed critical habitat, including in the tributary Kill Wash. We found no Big Spring spinedace in the lower 3.3 km of Condor Canyon. We tagged Big Spring spinedace ≥70 mm fork length (range 70–103 mm) with passive integrated transponder tags during October 2008 (n = 100) and March 2009 (n = 103) to document movement. At least 47 of these individuals moved from their release location (up to 2 km). Thirty-nine individuals moved to Kill Wash or the confluence area with Meadow Valley Wash. Ninety-three percent of movement occurred in spring 2009. Fish moved both upstream and downstream. We found no movement downstream over a small waterfall at river km 7.9 and recorded only one fish that moved downstream over Delmue Falls (a 12-m drop) at river km 6.1. At the time of tagging, there was no significant difference in fork length or condition between Big Spring Spinedace that were later detected moving and those not detected moving. We found no significant difference in fork length or condition at time of tagging of Big Spring spinedace ≥70 mm fork length that were detected moving and those not detected moving. Kill Wash and its confluence area appeared important to Big Spring spinedace; connectivity with these areas may be key to species persistence. These areas may provide a habitat template for restoration or translocation. The lower 3.3 km of

  13. Suitability of olive oil washing water as an electron donor in a feed batch operating bio-electrochemical system

    International Nuclear Information System (INIS)

    Fermoso, F.G.; Fernández-Rodríguez, M.J.; Jiménez-Rodríguez, A.; Serrano, A.; Borja, R.

    2017-01-01

    Olive oil washing water derived from the two-phase manufacturing process was assessed as an electron donor in a bio-electrochemical system (BES) operating at 35 ºC. Start-up was carried out by using acetate as a substrate for the BES, reaching a potential of around +680 mV. After day 54, BES was fed with olive oil washing water. The degradation of olive oil washing water in the BES generated a maximum voltage potential of around +520 mV and a Chemical Oxygen Demand (COD) removal efficiency of 41%. However, subsequent loads produced a decrease in the COD removal, while current and power density diminished greatly. The deterioration of these parameters could be a consequence of the accumulation of recalcitrant or inhibitory compounds, such as phenols. These results demonstrated that the use of olive oil washing water as an electron donor in a BES is feasible, although it has to be further investigated in order to make it more suitable for a real application. [es

  14. Efficiency of the surgical washing of hands with brush and without brush

    Directory of Open Access Journals (Sweden)

    Fresia Canales Carmona

    2013-10-01

    Full Text Available The purpose of this article is to establish the answer to a clinical question regarding the effectiveness ofpreoperative hygiene with hand washing brush or without it. This first technique has been performed on the skinto reduce transient bacteria and to inhibit the growth of resident microorganisms as a common and required actbefore any surgical procedure. Despite this measure and others such as prophylactic antibiotics, the mainoperative complication continues to be the surgical wound infection. Today, it is as prevalent as in the past withthe consequent negative effects derived from it, both for the institutions and for patients. Being controversialtoday which one is the most effective and safe surgical hand washing method for the binomial: professionalsurgical team/ patient, this study is done under the criteria of the Evidence-Based Nursing.A question was builtin PICO format (Personal, Intervention, Comparison and Outcome. After this is done, continues informationsearch in the databases GOOGLE ACADÉMICO, Pub Med, Cochrane y Base de Datos para la Investigación enEnfermería (BDIE We obtained 20 articles related to the topic of them 8, which fulfilled the set CASPe criteriato answer the clinical question, were analyzed. We conclude that washing hands with a brush is equally effectiveas without brush technique in terms of decreased of the superficial skin bacterial flora, although this technique hasadvantages over the traditional practice.

  15. Electrodialytic versus acid extraction of heavy metals from soil washing residue

    DEFF Research Database (Denmark)

    Jensen, Pernille E.; Ottosen, Lisbeth M.; Allard, Bert

    2012-01-01

    The feasibility of electrodialytic remediation (EDR) for treatment of suspended sludge after soil washing is in focus in the present paper. Five industrially contaminated soils were treated in laboratory scale remediation experiments, and the toxic elements of the investigation were: As, Cd, Cu, ...

  16. Analysis of vertical flow during ambient and pumped conditions in four monitoring wells at the Pantex Plant, Carson County, Texas, July-September 2008

    Science.gov (United States)

    Stanton, Gregory P.; Thomas, Jonathan V.; Stoval, Jeffery

    2009-01-01

    The Pantex Plant is a U.S. Department of Energy/National Nuclear Security Administration (USDOE/NNSA)-owned, contractor-operated facility managed by Babcock & Wilcox Technical Services Pantex, LLC (B&W Pantex) in Carson County, Texas, approximately 17 miles northeast of Amarillo. The U.S. Geological Survey, in cooperation with B&W Pantex through the USDOE/NNSA, made a series of flowmeter measurements and collected other borehole geophysical logs during July–September 2008 to analyze vertical flow in screened intervals of four selected monitoring wells (PTX01–1012, PTX06–1044, PTX06–1056, and PTX06–1068) at the Pantex Plant. Hydraulic properties (transmissivity values) of the section of High Plains (Ogallala) aquifer penetrated by the wells also were computed. Geophysical data were collected under ambient and pumped flow conditions in the four monitoring wells. Unusually large drawdowns occurred at two monitoring wells (PTX06–1044 and PTX06–1056) while the wells were pumped at relatively low rates. A decision was made to redevelop those wells, and logs were run again after redevelopment in the two monitoring wells.

  17. Soil washing physical separations test procedure - 300-FF-1 operable unit

    Energy Technology Data Exchange (ETDEWEB)

    Belden, R.D.

    1993-10-08

    This procedure provides the operations approach, a field sampling plan, and laboratory procedures for a soil washing test to be conducted by Alternative Remedial Technologies, Inc. (ART) in the 300-FF-1 area at the Hanford site. The {open_quotes}Quality Assurance Project Plan for the Soil Washing Physical Separations Test, 300-FF-1 Operable Unit,{close_quotes} Hanford, Washington, Alternative Remedial Technologies, Inc., February 1994 (QAPP) is provided in a separate document that presents the procedural and organizational guidelines for this test. This document describes specifications, responsibilities, and general procedures to be followed to conduct physical separation soil treatability tests in the North Process Pond of the 300-FF-1 Operable Unit (OU) at the Hanford Site. These procedures are based on the {open_quotes}300-FF-1 Physical Separations CERCLA Treatability Test Plan, DOE/RL 92-2l,{close_quotes} (DOE-RL 1993).

  18. Soil washing physical separations test procedure - 300-FF-1 operable unit

    International Nuclear Information System (INIS)

    Belden, R.D.

    1993-01-01

    This procedure provides the operations approach, a field sampling plan, and laboratory procedures for a soil washing test to be conducted by Alternative Remedial Technologies, Inc. (ART) in the 300-FF-1 area at the Hanford site. The open-quotes Quality Assurance Project Plan for the Soil Washing Physical Separations Test, 300-FF-1 Operable Unit,close quotes Hanford, Washington, Alternative Remedial Technologies, Inc., February 1994 (QAPP) is provided in a separate document that presents the procedural and organizational guidelines for this test. This document describes specifications, responsibilities, and general procedures to be followed to conduct physical separation soil treatability tests in the North Process Pond of the 300-FF-1 Operable Unit (OU) at the Hanford Site. These procedures are based on the open-quotes 300-FF-1 Physical Separations CERCLA Treatability Test Plan, DOE/RL 92-2l,close quotes (DOE-RL 1993)

  19. Geohydrologic reconnaissance of Lake Mead National Recreation Area; Las Vegas Wash to Opal Mountain, Nevada

    Science.gov (United States)

    Laney, R.L.

    1981-01-01

    The study is a geohydrologic reconnaissance of about 170 square miles in the Lake Mead National Recreation Area from Las Vegas Wash to Opal Mountain, Nevada. The study is one of a series that describes the geohydrology of the recreation area and that indentifies areas where water supplies can be developed. Precipitation in this arid area is about 5 inches per year. Streamflow is seasonal and extremely variable except for that in the Colorado River, which adjoins the area. Pan evaporation is more than 20 times greater than precipitation; therefore, regional ground-water supplies are meager except near the Colorado River, Lake Mead, and Lake Mohave. Large ground-water supplies can be developed near the river and lakes, and much smaller supplies may be obtained in a few favorable locations farther from the river and lakes. Ground water in most of the areas probably contains more than 1,000 milligrams per liter of dissolved solids, but water that contains less than 1,000 milligrams per liter of dissolved solids can be obtained within about 1 mile of the lakes. Crystalline rocks of metamorphic, intrusive and volcanic origin crop out in the area. These rocks are overlain by conglomerate and mudstone of the Muddy Creek Formation, gravel and conglomerate of the older alluvium, and sand and gravel of the Chemehuevi Formation and younger alluvium. The crystalline rocks, where sufficiently fractured, yield water to springs and would yield small amounts of water to favorably located wells. The poorly cemented and more permeable beds of the older alluvium, Chemehuevi Formation, and younger alluvium are the better potential aquifers, particularly along the Colorado River and Lakes Mead and Mohave. Thermal springs in the gorge of the Colorado River south of Hoover Dam discharge at least 2,580 acre-feet per year of water from the volcanic rocks and metamorphic and plutonic rocks. The discharge is much greater than could be infiltrated in the drainage basin above the springs

  20. Use of Electronic Loggers to Measure Changes in the Rates of Hand Washing with Soap in Low-Income Urban Households in India.

    Science.gov (United States)

    Wright, Richard L; Zillmer, Ruediger; Biran, Adam; Hall, Peter; Sidibe, Myriam

    2015-01-01

    We evaluated the utility of electronic loggers to measure the effects of a simple intervention designed to influence the rates of hand washing with soap within enclosed toilets and bathrooms in low-income urban households in Kerala, India. 58 households were given three items with embedded electronic loggers for a period of 2-5 days. Two logged soaps tracked hand and body washing in the bathroom. The third logged item was a water vessel used for flushing the toilet and for post-defecation anal cleansing; this served as a marker of toilet use. In addition, 28 households in a Soap by toilet arm were given an additional logged soap, to be kept by the toilet, and used for hand washing. Compared with the Soap in bathroom arm, the loggers in the Soap by toilet households recorded 73% greater daily use of soaps designated for hand washing (t(36)=2.92, psoap and changes in hand washing with soap after use of the toilet. Further adoption of logger technologies would enable more insightful studies of hand washing within urban environments.