WorldWideScience

Sample records for wafer-scale microphotonic device

  1. Toward wafer scale fabrication of graphene based spin valve devices.

    Science.gov (United States)

    Avsar, Ahmet; Yang, Tsung-Yeh; Bae, Sukang; Balakrishnan, Jayakumar; Volmer, Frank; Jaiswal, Manu; Yi, Zheng; Ali, Syed Rizwan; Güntherodt, Gernot; Hong, Byung Hee; Beschoten, Bernd; Özyilmaz, Barbaros

    2011-06-08

    We demonstrate injection, transport, and detection of spins in spin valve arrays patterned in both copper based chemical vapor deposition (Cu-CVD) synthesized wafer scale single layer and bilayer graphene. We observe spin relaxation times comparable to those reported for exfoliated graphene samples demonstrating that chemical vapor deposition specific structural differences such as nanoripples do not limit spin transport in the present samples. Our observations make Cu-CVD graphene a promising material of choice for large scale spintronic applications.

  2. Wafer-scale fabrication of glass-FEP-glass microfluidic devices for lipid bilayer experiments

    NARCIS (Netherlands)

    Bomer, Johan G.; Prokofyev, A.V.; van den Berg, Albert; le Gac, Severine

    2014-01-01

    We report a wafer-scale fabrication process for the production of glass-FEP-glass microdevices using UV-curable adhesive (NOA81) as gluing material, which is applied using a novel "spin & roll" approach. Devices are characterized for the uniformity of the gluing layer, presence of glue in the

  3. Fabrication of CVD graphene-based devices via laser ablation for wafer-scale characterization

    DEFF Research Database (Denmark)

    Mackenzie, David; Buron, Jonas Christian Due; Whelan, Patrick Rebsdorf

    2015-01-01

    Selective laser ablation of a wafer-scale graphene film is shown to provide flexible, high speed (1 wafer/hour) device fabrication while avoiding the degradation of electrical properties associated with traditional lithographic methods. Picosecond laser pulses with single pulse peak fluences of 1...

  4. Wafer-scale fabrication of glass-FEP-glass microfluidic devices for lipid bilayer experiments.

    Science.gov (United States)

    Bomer, Johan G; Prokofyev, Alexander V; van den Berg, Albert; Le Gac, Séverine

    2014-12-07

    We report a wafer-scale fabrication process for the production of glass-FEP-glass microdevices using UV-curable adhesive (NOA81) as gluing material, which is applied using a novel "spin & roll" approach. Devices are characterized for the uniformity of the gluing layer, presence of glue in the microchannels, and alignment precision. Experiments on lipid bilayers with electrophysiological recordings using a model pore-forming polypeptide are demonstrated.

  5. Microfluidic devices fabricated using fast wafer-scale LED-lithography patterning.

    Science.gov (United States)

    Challa, Pavan K; Kartanas, Tadas; Charmet, Jérôme; Knowles, Tuomas P J

    2017-01-01

    Current lithography approaches underpinning the fabrication of microfluidic devices rely on UV exposure of photoresists to define microstructures in these materials. Conventionally, this objective is achieved with gas discharge mercury lamps, which are capable of producing high intensity UV radiation. However, these sources are costly, have a comparatively short lifetime, necessitate regular calibration, and require significant time to warm up prior to exposure taking place. To address these limitations we exploit advances in solid state sources in the UV range and describe a fast and robust wafer-scale laboratory exposure system relying entirely on UV-Light emitting diode (UV-LED) illumination. As an illustration of the potential of this system for fast and low-cost microfluidic device production, we demonstrate the microfabrication of a 3D spray-drying microfluidic device and a 3D double junction microdroplet maker device.

  6. Wafer-Scale Ultrathin Two-Dimensional Conjugated Microporous Polymers: Preparation and Application in Heterostructure Devices.

    Science.gov (United States)

    Liu, Zhengdong; Song, Mengya; Ju, Shang; Huang, Xiao; Wang, Xiangjing; Shi, Xiaotong; Zhu, Ya; Wang, Zhan; Chen, Jie; Li, Hai; Cheng, Yingchun; Xie, Linghai; Liu, Juqing; Huang, Wei

    2018-01-31

    In this work, we report a universal surface-assisted oxidative polymerization strategy for wafer-scale fabrication of ultrathin two-dimensional conjugated microporous polymers (2D CMPs) on arbitrary substrates under ambient conditions. Three kinds of 2D CMPs with average thickness of 1.5-3.6 nm were prepared on SiO2/Si substrates by using carbazole based monomers. Moreover, 2D CMPs can be grown on reduced graphene oxide (rGO) substrate to construct large-area 2D CMP/rGO heterostructure. As a proof-of-concept demonstration, an organic vertical field-effect transistor based on 2D CMP/rGO heterostructures was fabricated, which exhibited typical p-type behavior with high reproducibility and on/off current ratio. Most importantly, the direct growth of large-area 2D CMPs on arbitrary substrates is compatible with the conventional processes in the semiconductor industry, and therefore is expected to expedite the development of 2D CMPs as building blocks for construction of practical electronic devices.

  7. Femtosecond laser ablation of transparent microphotonic devices and computer-generated holograms.

    Science.gov (United States)

    Alqurashi, Tawfiq; Montelongo, Yunuen; Penchev, Pavel; Yetisen, Ali K; Dimov, Stefan; Butt, Haider

    2017-09-21

    Femtosecond laser ablation allows direct patterning of engineering materials in industrial settings without requiring multistage processes such as photolithography or electron beam lithography. However, femtosecond lasers have not been widely used to construct volumetric microphotonic devices and holograms with high reliability and cost efficiency. Here, a direct femtosecond laser writing process is developed to rapidly produce transmission 1D/2D gratings, Fresnel Zone Plate lenses, and computer-generated holograms. The optical properties including light transmission, angle-dependent resolution, and light polarization effects for the microphotonic devices have been characterized. Varying the depth of the microgratings from 400 nm to 1.5 μm allowed the control over their transmission intensity profile. The optical properties of the 1D/2D gratings were validated through a geometrical theory of diffraction model involving 2D phase modulation. The produced Fresnel lenses had transmission efficiency of ∼60% at normal incidence and they preserved the polarization of incident light. The computer-generated holograms had an average transmission efficiency of 35% over the visible spectrum. These microphotonic devices had wettability resistance of contact angle ranging from 44° to 125°. These devices can be used in a variety of applications including wavelength-selective filters, dynamic displays, fiber optics, and biomedical devices.

  8. CMOS-analogous wafer-scale nanotube-on-insulator approach for submicrometer devices and integrated circuits using aligned nanotubes.

    Science.gov (United States)

    Ryu, Koungmin; Badmaev, Alexander; Wang, Chuan; Lin, Albert; Patil, Nishant; Gomez, Lewis; Kumar, Akshay; Mitra, Subhasish; Wong, H-S Philip; Zhou, Chongwu

    2009-01-01

    Massive aligned carbon nanotubes hold great potential but also face significant integration/assembly challenges for future beyond-silicon nanoelectronics. We report a wafer-scale processing of aligned nanotube devices and integrated circuits, including progress on essential technological components such as wafer-scale synthesis of aligned nanotubes, wafer-scale transfer of nanotubes to silicon wafers, metallic nanotube removal and chemical doping, and defect-tolerant integrated nanotube circuits. We have achieved synthesis of massive aligned nanotubes on complete 4 in. quartz and sapphire substrates, which were then transferred to 4 in. Si/SiO(2) wafers. CMOS analogous fabrication was performed to yield transistors and circuits with features down to 0.5 mum, with high current density approximately 20 muA/mum and good on/off ratios. In addition, chemical doping has been used to build fully integrated complementary inverter with a gain approximately 5, and a defect-tolerant design has been employed for NAND and NOR gates. This full-wafer approach could serve as a critical foundation for future integrated nanotube circuits.

  9. Electronic and optoelectronic devices based on chirality-enriched wafer-scale single-wall carbon nanotube thin films

    Science.gov (United States)

    Gao, Weilu; He, Xiaowei; Xie, Lijuan; Zhang, Qi; Haroz, Erik; Doorn, Stephen K.; Kono, Junichiro

    2015-03-01

    The unique and rich material properties of single-wall carbon nanotubes (SWCNTs) make them attractive for nano-electronic and optoelectronic applications. Slight changes in tube diameter and wrapping angle, defined by the chirality indices (n, m), can dramatically modify the bandstructure, which can be utilized for designing devices with tailored properties. However, it remains to be a challenge to fabricate macroscopic, single-chirality devices. Here, we introduce a simple way of producing chirality-enriched wafer-scale SWCNT films by combining recently developed solution-based polymer-modified sorting method and vacuum filtration. The produced thin films can be easily transferred onto any substrate to have a CMOS compatible wafer. We fabricated a transistor of (6,5)-enriched SWCNTs with an on/off ratio >103. Large-scale photothermoelectric-effect-based and photovoltaic-effect-based photodetectors made of (6,6)- and (6,5)-enriched films, respectively, will also be discussed.

  10. Wafer-scale processing technology for monolithically integrated GaSb thermophotovoltaic device array on semi-insulating GaAs substrate

    Science.gov (United States)

    Kim, Jung Min; Dutta, Partha S.; Brown, Eric; Borrego, Jose M.; Greiff, Paul

    2013-06-01

    This paper presents the entire fabrication and processing steps necessary for wafer scale monolithic integration of series interconnected GaSb devices grown on semi-insulating GaAs substrates. A device array has been fabricated on complete 50 mm (2 inch) diameter wafer using standard photolithography, wet chemical selective etching, dielectric deposition and single-sided metallization. For proof of concept of the wafer-scale feasibility of this process, six large-area series interconnected GaSb p-n junction thermophotovoltaic cells with each cell consisting of 24 small-area devices have been fabricated and characterized for its electrical connectivity. The fabrication process presented in this paper can be used for optoelectronic and electronic device technologies based on GaSb and related antimonide based compound semiconductors.

  11. Stationary Optical Concentrator Designs and Wafer Scale Monolithic Integration of Semiconductor Devices for Next Generation Photovoltaic Panels

    Science.gov (United States)

    Kim, Jung Min

    A major barrier in utilizing solar energy for large scale deployment is the cost of the photovoltaic (PV) systems. Several approaches have been used for the cost reduction such as by modifying PV system designs in addition to enhancing the efficiency of solar cells. Due to the high cost of materials, minimizing the use of solar cells such as in concentrator type systems is highly attractive for reducing the cost of the PV modules by focusing the incident light onto the PV cell. However concentrator PV systems (CPV) require constant tracking of the sun and hence are complex in design and expensive to operate, except in limited situations such as large scale PV power plants. It is desirable to design new concentrator type systems that do not require continuous tracking of the sun. These systems could ultimately reduce the PV system cost to a minimum while maximizing the power conversion efficiency. In this thesis we propose a simple design for a stationary concentrator photovoltaic (SCPV) system that could significantly reduce the cost of generating electricity using PV devices. Using optical ray tracing simulations, we have been able to design SCPV systems that could reduce the PV module cost by 2--10 times without compromising on the power conversion efficiency of the system. Another alternative approach for sustainable high efficiency PV system design is to develop low cost PV cells for terrestrial applications. To meet the demands of low cost and large scale production, larger and thinner (or flexible) substrates are required. We demonstrated the feasibility of fabricating monolithic interconnected PV devices at the wafer scale (2 inch wafers). In this study, GaSb PV cells grown on semi-insulating GaAs were used as the model material. Crucial device fabrication steps such as a selective etching process have been developed that is necessary for isolating individual devices on the wafer and interconnecting them with sub-micron scale accuracy. Selective etching of

  12. Integration of hexagonal boron nitride with quasi-freestanding epitaxial graphene: toward wafer-scale, high-performance devices.

    Science.gov (United States)

    Bresnehan, Michael S; Hollander, Matthew J; Wetherington, Maxwell; LaBella, Michael; Trumbull, Kathleen A; Cavalero, Randal; Snyder, David W; Robinson, Joshua A

    2012-06-26

    Hexagonal boron nitride (h-BN) is a promising dielectric material for graphene-based electronic devices. Here we investigate the potential of h-BN gate dielectrics, grown by chemical vapor deposition (CVD), for integration with quasi-freestanding epitaxial graphene (QFEG). We discuss the large scale growth of h-BN on copper foil via a catalytic thermal CVD process and the subsequent transfer of h-BN to a 75 mm QFEG wafer. X-ray photoelectron spectroscopy (XPS) measurements confirm the absence of h-BN/graphitic domains and indicate that the film is chemically stable throughout the transfer process, while Raman spectroscopy indicates a 42% relaxation of compressive stress following removal of the copper substrate and subsequent transfer of h-BN to QFEG. Despite stress-induced wrinkling observed in the films, Hall effect measurements show little degradation (Graphene transistors utilizing h-BN gates exhibit peak intrinsic cutoff frequencies >30 GHz (2.4× that of HfO(2)-based devices).

  13. HED-TIE: A wafer-scale approach for fabricating hybrid electronic devices with trench isolated electrodes

    Science.gov (United States)

    Banerjee, Sreetama; Bülz, Daniel; Solonenko, Dmytro; Reuter, Danny; Deibel, Carsten; Hiller, Karla; Zahn, Dietrich R. T.; Salvan, Georgeta

    2017-05-01

    Organic-inorganic hybrid electronic devices (HEDs) offer opportunities for functionalities that are not easily obtainable with either organic or inorganic materials individually. In the strive for down-scaling the channel length in planar geometry HEDs, the best results were achieved with electron beam lithography or nanoimprint lithography. Their application on the wafer level is, however, cost intensive and time consuming. Here, we propose trench isolated electrode (TIE) technology as a fast, cost effective, wafer-level approach for the fabrication of planar HEDs with electrode gaps in the range of 100 nm. We demonstrate that the formation of the organic channel can be realized by deposition from solution as well as by the thermal evaporation of organic molecules. To underline one key feature of planar HED-TIEs, namely full accessibility of the active area of the devices by external stimuli such as light, 6,13-bis (triisopropylsilylethynyl) (TIPS)-pentacene/Au HED-TIEs are successfully tested for possible application as hybrid photodetectors in the visible spectral range.

  14. Wafer-scale charge isolation technique

    Energy Technology Data Exchange (ETDEWEB)

    Colella, N.J.; Kimbrough, J.R.

    1994-12-31

    An apparatus and method are described which improve the performance of charge-coupled devices (CCD) in the presence of ionizing radiation. The invention is a wafer scale charge isolation technique which inhibits or reduces the flow of electrons created by the passage of ionizing radiation in the bulk regions of a silicon CCD. The technique has been tested in a device designed for operating in the infra-red wavelength band. The technique prevents charge from reaching the active charge collection volume of a pixel in a CCD.

  15. Wafer-scale micro-optics fabrication

    Science.gov (United States)

    Voelkel, Reinhard

    2012-07-01

    Micro-optics is an indispensable key enabling technology for many products and applications today. Probably the most prestigious examples are the diffractive light shaping elements used in high-end DUV lithography steppers. Highly-efficient refractive and diffractive micro-optical elements are used for precise beam and pupil shaping. Micro-optics had a major impact on the reduction of aberrations and diffraction effects in projection lithography, allowing a resolution enhancement from 250 nm to 45 nm within the past decade. Micro-optics also plays a decisive role in medical devices (endoscopes, ophthalmology), in all laser-based devices and fiber communication networks, bringing high-speed internet to our homes. Even our modern smart phones contain a variety of micro-optical elements. For example, LED flash light shaping elements, the secondary camera, ambient light and proximity sensors. Wherever light is involved, micro-optics offers the chance to further miniaturize a device, to improve its performance, or to reduce manufacturing and packaging costs. Wafer-scale micro-optics fabrication is based on technology established by the semiconductor industry. Thousands of components are fabricated in parallel on a wafer. This review paper recapitulates major steps and inventions in wafer-scale micro-optics technology. The state-of-the-art of fabrication, testing and packaging technology is summarized.

  16. Wafer-scale Mitochondrial Membrane Potential Assays

    Science.gov (United States)

    Lim, Tae-Sun; Davila, Antonio; Zand, Katayoun; Douglas, Wallace C.; Burke, Peter J.

    2012-01-01

    It has been reported that mitochondrial metabolic and biophysical parameters are associated with degenerative diseases and the aging process. To evaluate these biochemical parameters, current technology requires several hundred milligrams of isolated mitochondria for functional assays. Here, we demonstrate manufacturable wafer-scale mitochondrial functional assay lab-on-a-chip devices, which require mitochondrial protein quantities three orders of magnitude less than current assays, integrated onto 4” standard silicon wafer with new fabrication processes and materials. Membrane potential changes of isolated mitochondria from various well-established cell lines such as human HeLa cell line (Heb7A), human osteosarcoma cell line (143b) and mouse skeletal muscle tissue were investigated and compared. This second generation integrated lab-on-a-chip system developed here shows enhanced structural durability and reproducibility while increasing the sensitivity to changes in mitochondrial membrane potential by an order of magnitude as compared to first generation technologies. We envision this system to be a great candidate to substitute current mitochondrial assay systems. PMID:22627274

  17. Thermal Microphotonic Focal Plane Array (TM-FPA).

    Energy Technology Data Exchange (ETDEWEB)

    McCormick, Frederick Bossert; Lentine, Anthony L.; Wright, Jeremy Benjamin; Watts, Michael R.; Shaw, Michael J.; Rakich, Peter T.; Nielson, Gregory N.; Peters, David William; Zortman, William A.

    2009-10-01

    The advent of high quality factor (Q) microphotonic-resonators has led to the demonstration of high-fidelity optical sensors of many physical phenomena (e.g. mechanical, chemical, and biological sensing) often with far better sensitivity than traditional techniques. Microphotonic-resonators also offer potential advantages as uncooled thermal detectors including significantly better noise performance, smaller pixel size, and faster response times than current thermal detectors. In particular, microphotonic thermal detectors do not suffer from Johnson noise in the sensor, offer far greater responsivity, and greater thermal isolation as they do not require metallic leads to the sensing element. Such advantages make the prospect of a microphotonic thermal imager highly attractive. Here, we introduce the microphotonic thermal detection technique, present the theoretical basis for the approach, discuss our progress on the development of this technology and consider future directions for thermal microphotonic imaging. Already we have demonstrated viability of device fabrication with the successful demonstration of a 20{micro}m pixel, and a scalable readout technique. Further, to date, we have achieved internal noise performance (NEP{sub Internal} < 1pW/{radical}Hz) in a 20{micro}m pixel thereby exceeding the noise performance of the best microbolometers while simultaneously demonstrating a thermal time constant ({tau} = 2ms) that is five times faster. In all, this results in an internal detectivity of D*{sub internal} = 2 x 10{sup 9}cm {center_dot} {radical}Hz/W, while roughly a factor of four better than the best uncooled commercial microbolometers, future demonstrations should enable another order of magnitude in sensitivity. While much work remains to achieve the level of maturity required for a deployable technology, already, microphotonic thermal detection has demonstrated considerable potential.

  18. Wafer-scale pixelated detector system

    Energy Technology Data Exchange (ETDEWEB)

    Fahim, Farah; Deptuch, Grzegorz; Zimmerman, Tom

    2017-10-17

    A large area, gapless, detection system comprises at least one sensor; an interposer operably connected to the at least one sensor; and at least one application specific integrated circuit operably connected to the sensor via the interposer wherein the detection system provides high dynamic range while maintaining small pixel area and low power dissipation. Thereby the invention provides methods and systems for a wafer-scale gapless and seamless detector systems with small pixels, which have both high dynamic range and low power dissipation.

  19. Laser tweezer actuated microphotonic array devices for high resolution imaging and analysis in chip-based biosystems

    Science.gov (United States)

    Birkbeck, Aaron L.

    A new technology is developed that functionally integrates arrays of lasers and micro-optics into microfluidic systems for the purpose of imaging, analyzing, and manipulating objects and biological cells. In general, the devices and technologies emerging from this area either lack functionality through the reliance on mechanical systems or provide a serial-based, time consuming approach. As compared to the current state of art, our all-optical design methodology has several distinguishing features, such as parallelism, high efficiency, low power, auto-alignment, and high yield fabrication methods, which all contribute to minimizing the cost of the integration process. The potential use of vertical cavity surface emitting lasers (VCSELs) for the creation of two-dimensional arrays of laser optical tweezers that perform independently controlled, parallel capture, and transport of large numbers of individual objects and biological cells is investigated. One of the primary biological applications for which VCSEL array sourced laser optical tweezers are considered is the formation of engineered tissues through the manipulation and spatial arrangement of different types of cells in a co-culture. Creating devices that combine laser optical tweezers with select micro-optical components permits optical imaging and analysis functions to take place inside the microfluidic channel. One such device is a micro-optical spatial filter whose motion and alignment is controlled using a laser optical tweezer. Unlike conventional spatial filter systems, our device utilizes a refractive optical element that is directly incorporated onto the lithographically patterned spatial filter. This allows the micro-optical spatial filter to automatically align itself in three-dimensions to the focal point of the microscope objective, where it then filters out the higher frequency additive noise components present in the laser beam. As a means of performing high resolution imaging in the

  20. Wafer scale oblique angle plasma etching

    Energy Technology Data Exchange (ETDEWEB)

    Burckel, David Bruce; Jarecki, Jr., Robert L.; Finnegan, Patrick Sean

    2017-05-23

    Wafer scale oblique angle etching of a semiconductor substrate is performed in a conventional plasma etch chamber by using a fixture that supports a multiple number of separate Faraday cages. Each cage is formed to include an angled grid surface and is positioned such that it will be positioned over a separate one of the die locations on the wafer surface when the fixture is placed over the wafer. The presence of the Faraday cages influences the local electric field surrounding each wafer die, re-shaping the local field to be disposed in alignment with the angled grid surface. The re-shaped plasma causes the reactive ions to follow a linear trajectory through the plasma sheath and angled grid surface, ultimately impinging the wafer surface at an angle. The selected geometry of the Faraday cage angled grid surface thus determines the angle at with the reactive ions will impinge the wafer.

  1. Thermal microphotonic sensor and sensor array

    Science.gov (United States)

    Watts, Michael R [Albuquerque, NM; Shaw, Michael J [Tijeras, NM; Nielson, Gregory N [Albuquerque, NM; Lentine, Anthony L [Albuquerque, NM

    2010-02-23

    A thermal microphotonic sensor is disclosed for detecting infrared radiation using heat generated by the infrared radiation to shift the resonant frequency of an optical resonator (e.g. a ring resonator) to which the heat is coupled. The shift in the resonant frequency can be determined from light in an optical waveguide which is evanescently coupled to the optical resonator. An infrared absorber can be provided on the optical waveguide either as a coating or as a plate to aid in absorption of the infrared radiation. In some cases, a vertical resonant cavity can be formed about the infrared absorber to further increase the absorption of the infrared radiation. The sensor can be formed as a single device, or as an array for imaging the infrared radiation.

  2. Fabrication of thermal microphotonic sensors and sensor arrays

    Science.gov (United States)

    Shaw, Michael J.; Watts, Michael R.; Nielson, Gregory N.

    2010-10-26

    A thermal microphotonic sensor is fabricated on a silicon substrate by etching an opening and a trench into the substrate, and then filling in the opening and trench with silicon oxide which can be deposited or formed by thermally oxidizing a portion of the silicon substrate surrounding the opening and trench. The silicon oxide forms a support post for an optical resonator which is subsequently formed from a layer of silicon nitride, and also forms a base for an optical waveguide formed from the silicon nitride layer. Part of the silicon substrate can be selectively etched away to elevate the waveguide and resonator. The thermal microphotonic sensor, which is useful to detect infrared radiation via a change in the evanescent coupling of light between the waveguide and resonator, can be formed as a single device or as an array.

  3. Wafer scale integration of catalyst dots into nonplanar microsystems

    DEFF Research Database (Denmark)

    Gjerde, Kjetil; Kjelstrup-Hansen, Jakob; Gammelgaard, Lauge

    2007-01-01

    In order to successfully integrate bottom-up fabricated nanostructures such as carbon nanotubes or silicon, germanium, or III-V nanowires into microelectromechanical systems on a wafer scale, reliable ways of integrating catalyst dots are needed. Here, four methods for integrating sub-100-nm...... diameter nickel catalyst dots on a wafer scale are presented and compared. Three of the methods are based on a p-Si layer utilized as an in situ mask, an encapsulating layer, and a sacrificial window mask, respectively. All methods enable precise positioning of nickel catalyst dots at the end...

  4. Wafer-scale nanostructure formation inside vertical nano-pores

    NARCIS (Netherlands)

    Berenschot, Johan W.; Sun, Xingwu; Le The, Hai; Tiggelaar, Roald M.; de Boer, Meint J.; Eijkel, Jan C.T.; Gardeniers, Johannes G.E.; Tas, Niels Roelof; Sarajlic, Edin

    We propose a wafer-scale technique for nanostructure formation inside vertically oriented, through-membrane nano-pores. It uses 50 nm monocrystalline silicon pillars as a mold, embedded in a silicon nitride membrane formed in an innovative step. The proposed technique paves the way towards advanced

  5. Wafer scale coating of polymer cantilever fabricated by nanoimprint lithography

    DEFF Research Database (Denmark)

    Greve, Anders; Dohn, Søren; Keller, Stephan Urs

    2010-01-01

    Microcantilevers can be fabricated in TOPAS by nanoimprint lithography, with the dimensions of 500 ¿m length 4.5 ¿m thickness and 100 ¿m width. By using a plasma polymerization technique it is possible to selectively functionalize individually cantilevers with a polymer coating, on wafer scale...

  6. Silicon Wafer-Scale Substrate for Microshutters and Detector Arrays

    Science.gov (United States)

    Jhabvala, Murzy; Franz, David E.; Ewin, Audrey J.; Jhabvala, Christine; Babu, Sachi; Snodgrass, Stephen; Costen, Nicholas; Zincke, Christian

    2009-01-01

    The silicon substrate carrier was created so that a large-area array (in this case 62,000+ elements of a microshutter array) and a variety of discrete passive and active devices could be mounted on a single board, similar to a printed circuit board. However, the density and number of interconnects far exceeds the capabilities of printed circuit board technology. To overcome this hurdle, a method was developed to fabricate this carrier out of silicon and implement silicon integrated circuit (IC) technology. This method achieves a large number of high-density metal interconnects; a 100-percent yield over a 6-in. (approximately equal to 15-cm) diameter wafer (one unit per wafer); a rigid, thermally compatible structure (all components and operating conditions) to cryogenic temperatures; re-workability and component replaceability, if required; and the ability to precisely cut large-area holes through the substrate. A method that would employ indium bump technology along with wafer-scale integration onto a silicon carrier was also developed. By establishing a silicon-based version of a printed circuit board, the objectives could be met with one solution. The silicon substrate would be 2 mm thick to survive the environmental loads of a launch. More than 2,300 metal traces and over 1,500 individual wire bonds are required. To mate the microshutter array to the silicon substrate, more than 10,000 indium bumps are required. A window was cut in the substrate to allow the light signal to pass through the substrate and reach the microshutter array. The substrate was also the receptacle for multiple unpackaged IC die wire-bonded directly to the substrate (thus conserving space over conventionally packaged die). Unique features of this technology include the implementation of a 2-mmthick silicon wafer to withstand extreme mechanical loads (from a rocket launch); integrated polysilicon resistor heaters directly on the substrate; the precise formation of an open aperture

  7. Wafer scale integration of reduced graphene oxide by novel laser processing at room temperature in air

    Science.gov (United States)

    Bhaumik, Anagh; Narayan, Jagdish

    2016-09-01

    Physical properties of reduced graphene oxide (rGO) strongly depend on the ratio of sp2 to sp3 hybridized carbon atoms, the presence of different functional groups, and the characteristics of the substrates. This research for the very first time illustrates successful wafer scale integration of 2D rGO with Cu/TiN/Si, employing pulsed laser deposition followed by laser annealing of carbon-doped copper layers using nanosecond excimer lasers. The XRD, SEM, and Raman spectroscopy measurements indicate the presence of large area rGO onto Si having Raman active vibrational modes: D, G, and 2D. A high resolution SEM depicts the morphology and formation of rGO from zone-refined carbon formed after nanosecond laser annealing. Temperature-dependent resistance data of rGO thin films follow the Efros-Shklovskii variable range hopping (VRH) model in the low-temperature region and Arrhenius conduction in the high-temperature regime. The photoluminescence spectra also reveal a less intense and broader blue fluorescence spectra, indicating the presence of miniature sized sp2 domains in the near vicinity of π* electronic states which favor the VRH transport phenomena. This wafer scale integration of rGO with Si employing a laser annealing technique will be useful for multifunctional integrated electronic devices and will open a new frontier for further extensive research in these functionalized 2D materials.

  8. Wafer-scale synthesis of monolayer and few-layer MoS2 via thermal vapor sulfurization

    Science.gov (United States)

    Robertson, John; Liu, Xue; Yue, Chunlei; Escarra, Matthew; Wei, Jiang

    2017-12-01

    Monolayer molybdenum disulfide (MoS2) is an atomically thin, direct bandgap semiconductor crystal potentially capable of miniaturizing optoelectronic devices to an atomic scale. However, the development of 2D MoS2-based optoelectronic devices depends upon the existence of a high optical quality and large-area monolayer MoS2 synthesis technique. To address this need, we present a thermal vapor sulfurization (TVS) technique that uses powder MoS2 as a sulfur vapor source. The technique reduces and stabilizes the flow of sulfur vapor, enabling monolayer wafer-scale MoS2 growth. MoS2 thickness is also controlled with great precision; we demonstrate the ability to synthesize MoS2 sheets between 1 and 4 layers thick, while also showing the ability to create films with average thickness intermediate between integer layer numbers. The films exhibit wafer-scale coverage and uniformity, with electrical quality varying depending on the final thickness of the grown MoS2. The direct bandgap of grown monolayer MoS2 is analyzed using internal and external photoluminescence quantum efficiency. The photoluminescence quantum efficiency is shown to be competitive with untreated exfoliated MoS2 monolayer crystals. The ability to consistently grow wafer-scale monolayer MoS2 with high optical quality makes this technique a valuable tool for the development of 2D optoelectronic devices such as photovoltaics, detectors, and light emitters.

  9. Wafer-scale plasmonic and photonic crystal sensors

    Science.gov (United States)

    George, M. C.; Liu, J.-N.; Farhang, A.; Williamson, B.; Black, M.; Wangensteen, T.; Fraser, J.; Petrova, R.; Cunningham, B. T.

    2015-08-01

    200 mm diameter wafer-scale fabrication, metrology, and optical modeling results are reviewed for surface plasmon resonance (SPR) sensors based on 2-D metallic nano-dome and nano-hole arrays (NHA's) as well as 1-D photonic crystal sensors based on a leaky-waveguide mode resonance effect, with potential applications in label free sensing, surface enhanced Raman spectroscopy (SERS), and surface-enhanced fluorescence spectroscopy (SEFS). Potential markets include micro-arrays for medical diagnostics, forensic testing, environmental monitoring, and food safety. 1-D and 2-D nanostructures were fabricated on glass, fused silica, and silicon wafers using optical lithography and semiconductor processing techniques. Wafer-scale optical metrology results are compared to FDTD modeling and presented along with application-based performance results, including label-free plasmonic and photonic crystal sensing of both surface binding kinetics and bulk refractive index changes. In addition, SEFS and SERS results are presented for 1-D photonic crystal and 2-D metallic nano-array structures. Normal incidence transmittance results for a 550 nm pitch NHA showed good bulk refractive index sensitivity, however an intensity-based design with 665 nm pitch was chosen for use as a compact, label-free sensor at both 650 and 632.8 nm wavelengths. The optimized NHA sensor gives an SPR shift of about 480 nm per refractive index unit when detecting a series of 0-40% glucose solutions, but according to modeling shows about 10 times greater surface sensitivity when operating at 532 nm. Narrow-band photonic crystal resonance sensors showed quality factors over 200, with reasonable wafer-uniformity in terms of both resonance position and peak height.

  10. Versatile pattern generation of periodic, high aspect ratio Si nanostructure arrays with sub-50-nm resolution on a wafer scale.

    Science.gov (United States)

    Ho, Jian-Wei; Wee, Qixun; Dumond, Jarrett; Tay, Andrew; Chua, Soo-Jin

    2013-12-01

    We report on a method of fabricating variable patterns of periodic, high aspect ratio silicon nanostructures with sub-50-nm resolution on a wafer scale. The approach marries step-and-repeat nanoimprint lithography (NIL) and metal-catalyzed electroless etching (MCEE), enabling near perfectly ordered Si nanostructure arrays of user-defined patterns to be controllably and rapidly generated on a wafer scale. Periodic features possessing circular, hexagonal, and rectangular cross-sections with lateral dimensions down to sub-50 nm, in hexagonal or square array configurations and high array packing densities up to 5.13 × 107 structures/mm2 not achievable by conventional UV photolithography are fabricated using this top-down approach. By suitably tuning the duration of catalytic etching, variable aspect ratio Si nanostructures can be formed. As the etched Si pattern depends largely on the NIL mould which is patterned by electron beam lithography (EBL), the technique can be used to form patterns not possible with self-assembly methods, nanosphere, and interference lithography for replication on a wafer scale. Good chemical resistance of the nanoimprinted mask and adhesion to the Si substrate facilitate good pattern transfer and preserve the smooth top surface morphology of the Si nanostructures as shown in TEM. This approach is suitable for generating Si nanostructures of controlled dimensions and patterns, with high aspect ratio on a wafer level suitable for semiconductor device production.

  11. High-mobility three-atom-thick semiconducting films with wafer-scale homogeneity.

    Science.gov (United States)

    Kang, Kibum; Xie, Saien; Huang, Lujie; Han, Yimo; Huang, Pinshane Y; Mak, Kin Fai; Kim, Cheol-Joo; Muller, David; Park, Jiwoong

    2015-04-30

    The large-scale growth of semiconducting thin films forms the basis of modern electronics and optoelectronics. A decrease in film thickness to the ultimate limit of the atomic, sub-nanometre length scale, a difficult limit for traditional semiconductors (such as Si and GaAs), would bring wide benefits for applications in ultrathin and flexible electronics, photovoltaics and display technology. For this, transition-metal dichalcogenides (TMDs), which can form stable three-atom-thick monolayers, provide ideal semiconducting materials with high electrical carrier mobility, and their large-scale growth on insulating substrates would enable the batch fabrication of atomically thin high-performance transistors and photodetectors on a technologically relevant scale without film transfer. In addition, their unique electronic band structures provide novel ways of enhancing the functionalities of such devices, including the large excitonic effect, bandgap modulation, indirect-to-direct bandgap transition, piezoelectricity and valleytronics. However, the large-scale growth of monolayer TMD films with spatial homogeneity and high electrical performance remains an unsolved challenge. Here we report the preparation of high-mobility 4-inch wafer-scale films of monolayer molybdenum disulphide (MoS2) and tungsten disulphide, grown directly on insulating SiO2 substrates, with excellent spatial homogeneity over the entire films. They are grown with a newly developed, metal-organic chemical vapour deposition technique, and show high electrical performance, including an electron mobility of 30 cm(2) V(-1) s(-1) at room temperature and 114 cm(2) V(-1) s(-1) at 90 K for MoS2, with little dependence on position or channel length. With the use of these films we successfully demonstrate the wafer-scale batch fabrication of high-performance monolayer MoS2 field-effect transistors with a 99% device yield and the multi-level fabrication of vertically stacked transistor devices for three

  12. Tailoring the graphene/silicon carbide interface for monolithic wafer-scale electronics

    National Research Council Canada - National Science Library

    Hertel, S; Waldmann, D; Jobst, J; Albert, A; Albrecht, M; Reshanov, S; Schöner, A; Krieger, M; Weber, H B

    2012-01-01

    .... Here in the search for a comprehensive concept for wafer-scale graphene electronics, we present a monolithic transistor that uses the entire material system epitaxial graphene on silicon carbide (0001...

  13. Wafer-scale design of lightweight and transparent electronics that wraps around hairs

    Science.gov (United States)

    Salvatore, Giovanni A.; Münzenrieder, Niko; Kinkeldei, Thomas; Petti, Luisa; Zysset, Christoph; Strebel, Ivo; Büthe, Lars; Tröster, Gerhard

    2014-01-01

    Electronics on very thin substrates have shown remarkable bendability, conformability and lightness, which are important attributes for biological tissues sensing, wearable or implantable devices. Here we propose a wafer-scale process scheme to realize ultra flexible, lightweight and transparent electronics on top of a 1-μm thick parylene film that is released from the carrier substrate after the dissolution in water of a polyvinyl- alcohol layer. The thin substrate ensures extreme flexibility, which is demonstrated by transistors that continue to work when wrapped around human hairs. In parallel, the use of amorphous oxide semiconductor and high-K dielectric enables the realization of analogue amplifiers operating at 12 V and above 1 MHz. Electronics can be transferred on any object, surface and on biological tissues like human skin and plant leaves. We foresee a potential application as smart contact lenses, covered with light, transparent and flexible devices, which could serve to monitor intraocular pressure for glaucoma disease.

  14. Cascading wafer-scale integrated graphene complementary inverters under ambient conditions.

    Science.gov (United States)

    Rizzi, Laura Giorgia; Bianchi, Massimiliano; Behnam, Ashkan; Carrion, Enrique; Guerriero, Erica; Polloni, Laura; Pop, Eric; Sordan, Roman

    2012-08-08

    The fundamental building blocks of digital electronics are logic gates which must be capable of cascading such that more complex logic functions can be realized. Here we demonstrate integrated graphene complementary inverters which operate with the same input and output voltage logic levels, thus allowing cascading. We obtain signal matching under ambient conditions with inverters fabricated from wafer-scale graphene grown by chemical vapor deposition (CVD). Monolayer graphene was incorporated in self-aligned field-effect transistors in which the top gate overlaps with the source and drain contacts. This results in full-channel gating and leads to the highest low-frequency voltage gain reported so far in top-gated CVD graphene devices operating in air ambient, A(v) ∼ -5. Such gain enabled logic inverters with the same voltage swing of 0.56 V at their input and output. Graphene inverters could find their way in realistic applications where high-speed operation is desired but power dissipation is not a concern, similar to emitter-coupled logic.

  15. Tailoring the graphene/silicon carbide interface for monolithic wafer-scale electronics.

    Science.gov (United States)

    Hertel, S; Waldmann, D; Jobst, J; Albert, A; Albrecht, M; Reshanov, S; Schöner, A; Krieger, M; Weber, H B

    2012-07-17

    Graphene is an outstanding electronic material, predicted to have a role in post-silicon electronics. However, owing to the absence of an electronic bandgap, graphene switching devices with high on/off ratio are still lacking. Here in the search for a comprehensive concept for wafer-scale graphene electronics, we present a monolithic transistor that uses the entire material system epitaxial graphene on silicon carbide (0001). This system consists of the graphene layer with its vanishing energy gap, the underlying semiconductor and their common interface. The graphene/semiconductor interfaces are tailor-made for ohmic as well as for Schottky contacts side-by-side on the same chip. We demonstrate normally on and normally off operation of a single transistor with on/off ratios exceeding 10(4) and no damping at megahertz frequencies. In its simplest realization, the fabrication process requires only one lithography step to build transistors, diodes, resistors and eventually integrated circuits without the need of metallic interconnects.

  16. Wafer-Scale High-Throughput Ordered Growth of Vertically Aligned ZnO Nanowire Arrays

    KAUST Repository

    Wei, Yaguang

    2010-09-08

    This article presents an effective approach for patterned growth of vertically aligned ZnO nanowire (NW) arrays with high throughput and low cost at wafer scale without using cleanroom technology. Periodic hole patterns are generated using laser interference lithography on substrates coated with the photoresist SU-8. ZnO NWs are selectively grown through the holes via a low-temperature hydrothermal method without using a catalyst and with a superior control over orientation, location/density, and as-synthesized morphology. The development of textured ZnO seed layers for replacing single crystalline GaN and ZnO substrates extends the large-scale fabrication of vertically aligned ZnO NW arrays on substrates of other materials, such as polymers, Si, and glass. This combined approach demonstrates a novel method of manufacturing large-scale patterned one-dimensional nanostructures on various substrates for applications in energy harvesting, sensing, optoelectronics, and electronic devices. © 2010 American Chemical Society.

  17. Toward the synthesis of wafer-scale single-crystal graphene on copper foils.

    Science.gov (United States)

    Yan, Zheng; Lin, Jian; Peng, Zhiwei; Sun, Zhengzong; Zhu, Yu; Li, Lei; Xiang, Changsheng; Samuel, E Loïc; Kittrell, Carter; Tour, James M

    2012-10-23

    In this research, we constructed a controlled chamber pressure CVD (CP-CVD) system to manipulate graphene's domain sizes and shapes. Using this system, we synthesized large (~4.5 mm(2)) single-crystal hexagonal monolayer graphene domains on commercial polycrystalline Cu foils (99.8% purity), indicating its potential feasibility on a large scale at low cost. The as-synthesized graphene had a mobility of positive charge carriers of ~11,000 cm(2) V(-1) s(-1) on a SiO(2)/Si substrate at room temperature, suggesting its comparable quality to that of exfoliated graphene. The growth mechanism of Cu-based graphene was explored by studying the influence of varied growth parameters on graphene domain sizes. Cu pretreatments, electrochemical polishing, and high-pressure annealing are shown to be critical for suppressing graphene nucleation site density. A pressure of 108 Torr was the optimal chamber pressure for the synthesis of large single-crystal monolayer graphene. The synthesis of one graphene seed was achieved on centimeter-sized Cu foils by optimizing the flow rate ratio of H(2)/CH(4). This work should provide clear guidelines for the large-scale synthesis of wafer-scale single-crystal graphene, which is essential for the optimized graphene device fabrication.

  18. Wafer-scale epitaxial graphene on SiC for sensing applications

    Science.gov (United States)

    Karlsson, Mikael; Wang, Qin; Zhao, Yichen; Zhao, Wei; Toprak, Muhammet S.; Iakimov, Tihomir; Ali, Amer; Yakimova, Rositza; Syväjärvi, Mikael; Ivanov, Ivan G.

    2015-12-01

    The epitaxial graphene-on-silicon carbide (SiC-G) has advantages of high quality and large area coverage owing to a natural interface between graphene and SiC substrate with dimension up to 100 mm. It enables cost effective and reliable solutions for bridging the graphene-based sensors/devices from lab to industrial applications and commercialization. In this work, the structural, optical and electrical properties of wafer-scale graphene grown on 2'' 4H semi-insulating (SI) SiC utilizing sublimation process were systemically investigated with focus on evaluation of the graphene's uniformity across the wafer. As proof of concept, two types of glucose sensors based on SiC-G/Nafion/Glucose-oxidase (GOx) and SiC-G/Nafion/Chitosan/GOx were fabricated and their electrochemical properties were characterized by cyclic voltammetry (CV) measurements. In addition, a few similar glucose sensors based on graphene by chemical synthesis using modified Hummer's method were also fabricated for comparison.

  19. Deterministic patterned growth of high-mobility large-crystal graphene: a path towards wafer scale integration

    Science.gov (United States)

    Miseikis, Vaidotas; Bianco, Federica; David, Jérémy; Gemmi, Mauro; Pellegrini, Vittorio; Romagnoli, Marco; Coletti, Camilla

    2017-06-01

    We demonstrate rapid deterministic (seeded) growth of large single-crystals of graphene by chemical vapour deposition (CVD) utilising pre-patterned copper substrates with chromium nucleation sites. Arrays of graphene single-crystals as large as several hundred microns are grown with a periodicity of up to 1 mm. The graphene is transferred to target substrates using aligned and contamination- free semi-dry transfer. The high quality of the synthesised graphene is confirmed by Raman spectroscopy and transport measurements, demonstrating room-temperature carrier mobility of 21 000 cm2 V-1 s-1 when transferred on top of hexagonal boron nitride. By tailoring the nucleation of large single-crystals according to the desired device geometry, it will be possible to produce complex device architectures based on single-crystal graphene, thus paving the way to the adoption of CVD graphene in wafer-scale fabrication.

  20. Layer-by-layer assembly of two-dimensional materials into wafer-scale heterostructures

    Science.gov (United States)

    Kang, Kibum; Lee, Kan-Heng; Han, Yimo; Gao, Hui; Xie, Saien; Muller, David A.; Park, Jiwoong

    2017-10-01

    High-performance semiconductor films with vertical compositions that are designed to atomic-scale precision provide the foundation for modern integrated circuitry and novel materials discovery. One approach to realizing such films is sequential layer-by-layer assembly, whereby atomically thin two-dimensional building blocks are vertically stacked, and held together by van der Waals interactions. With this approach, graphene and transition-metal dichalcogenides--which represent one- and three-atom-thick two-dimensional building blocks, respectively--have been used to realize previously inaccessible heterostructures with interesting physical properties. However, no large-scale assembly method exists at present that maintains the intrinsic properties of these two-dimensional building blocks while producing pristine interlayer interfaces, thus limiting the layer-by-layer assembly method to small-scale proof-of-concept demonstrations. Here we report the generation of wafer-scale semiconductor films with a very high level of spatial uniformity and pristine interfaces. The vertical composition and properties of these films are designed at the atomic scale using layer-by-layer assembly of two-dimensional building blocks under vacuum. We fabricate several large-scale, high-quality heterostructure films and devices, including superlattice films with vertical compositions designed layer-by-layer, batch-fabricated tunnel device arrays with resistances that can be tuned over four orders of magnitude, band-engineered heterostructure tunnel diodes, and millimetre-scale ultrathin membranes and windows. The stacked films are detachable, suspendable and compatible with water or plastic surfaces, which will enable their integration with advanced optical and mechanical systems.

  1. Through-Wafer Optical Interconnects For Multi-Wafer Wafer-Scale Integrated Architectures

    Science.gov (United States)

    Hornak, L. A.; Tewksbury, S. K.; Hatamian, M.; Ligtenberg, A.; Sugla, B.; Franzon, P.

    1986-12-01

    Hybrid mounting of optical components, combined perhaps with integrated optical waveguides and lenses on a large area silicon, wafer-scale integrated (WSI) electronic circuit provides one potential approach to combine advanced electronic and photonic functions. The desire to achieve a high degree of parallelism in multi-wafer WSI-based architectures has stimulated study of three-dimensional interconnect structures obtained by stacking wafer circuit boards and. providing interconnections vertically between wafers over the entire wafer area in addition to planar connections. While presently it is difficult for optical interconnects to compete with electrical interconnects in the wafer plane, it is appropriate to look at vertical optical interconnections between wafer planes since the corresponding conductive structures would be large in area and may impede system repairability. The ability to pass information optically between circuit planes without mechanical electrical contacts offers potential advantages for multi-wafer WSI or other dense three-dimensional architectures. However, while optical waveguides are readily fabricated in the plane of the wafer, waveguiding vertically through the wafer is difficult. If additional processing is required for waveguides or lenses, it should be compatible with standard VLSI processing. This paper presents one straightforward method of meeting this criterion. Using optical device technology operating at wavelengths beyond the ≍1.1μm Si absorption cutoff, low loss, through-wafer propagation between WSI circuit boards can be achieved over the distances of interest (≍1mm) with the interstitial Si wafers as part of the interconnect "free-space" transmission medium. The thickness of existing VLSI layers can be readily adjusted in featureless regions of the wafer to provide antireflection windows such that the transmittance can be raised to ≍77% for n-type and to ≍97% for p-type silicon. Optical interconnect source

  2. Wafer-Scale Leaning Silver Nanopillars for Molecular Detection at Ultra-Low Concentrations

    DEFF Research Database (Denmark)

    Wu, Kaiyu; Rindzevicius, Tomas; Schmidt, Michael Stenbæk

    2015-01-01

    Wafer-scale surface-enhanced Raman scattering (SERS) substrates fabricated using maskless lithography are important for scalable production targets. Large-area, leaning silver-capped silicon nanopillar (Ag NP) structures suitable for SERS molecular detection at extremely low analyte concentrations...

  3. Dimensional Control in Corner Lithography for Wafer-Scale Fabrication of Nano-Apertures

    NARCIS (Netherlands)

    Burouni, N.; Berenschot, Johan W.; Elwenspoek, Michael Curt; Tas, Niels Roelof

    2011-01-01

    In this paper we investigate a new method to fabricate 3D-oriented nanostructures in wafer scale, and apply it to fabricate a nano-apertures at the apex of a pyramid. A number of new technologies require the use of apertures to serve as electrical, nano fluidic or optical probes. Controlling the

  4. Face-to-face transfer of wafer-scale graphene films

    Science.gov (United States)

    Gao, Libo; Ni, Guang-Xin; Liu, Yanpeng; Liu, Bo; Castro Neto, Antonio H.; Loh, Kian Ping

    2014-01-01

    Graphene has attracted worldwide interest since its experimental discovery, but the preparation of large-area, continuous graphene film on SiO2/Si wafers, free from growth-related morphological defects or transfer-induced cracks and folds, remains a formidable challenge. Growth of graphene by chemical vapour deposition on Cu foils has emerged as a powerful technique owing to its compatibility with industrial-scale roll-to-roll technology. However, the polycrystalline nature and microscopic roughness of Cu foils means that such roll-to-roll transferred films are not devoid of cracks and folds. High-fidelity transfer or direct growth of high-quality graphene films on arbitrary substrates is needed to enable wide-ranging applications in photonics or electronics, which include devices such as optoelectronic modulators, transistors, on-chip biosensors and tunnelling barriers. The direct growth of graphene film on an insulating substrate, such as a SiO2/Si wafer, would be useful for this purpose, but current research efforts remain grounded at the proof-of-concept stage, where only discontinuous, nanometre-sized islands can be obtained. Here we develop a face-to-face transfer method for wafer-scale graphene films that is so far the only known way to accomplish both the growth and transfer steps on one wafer. This spontaneous transfer method relies on nascent gas bubbles and capillary bridges between the graphene film and the underlying substrate during etching of the metal catalyst, which is analogous to the method used by tree frogs to remain attached to submerged leaves. In contrast to the previous wet or dry transfer results, the face-to-face transfer does not have to be done by hand and is compatible with any size and shape of substrate; this approach also enjoys the benefit of a much reduced density of transfer defects compared with the conventional transfer method. Most importantly, the direct growth and spontaneous attachment of graphene on the underlying

  5. Wafer-scale integration of sacrificial nanofluidic chips for detecting and manipulating single DNA molecules.

    Science.gov (United States)

    Wang, Chao; Nam, Sung-Wook; Cotte, John M; Jahnes, Christopher V; Colgan, Evan G; Bruce, Robert L; Brink, Markus; Lofaro, Michael F; Patel, Jyotica V; Gignac, Lynne M; Joseph, Eric A; Rao, Satyavolu Papa; Stolovitzky, Gustavo; Polonsky, Stanislav; Lin, Qinghuang

    2017-01-23

    Wafer-scale fabrication of complex nanofluidic systems with integrated electronics is essential to realizing ubiquitous, compact, reliable, high-sensitivity and low-cost biomolecular sensors. Here we report a scalable fabrication strategy capable of producing nanofluidic chips with complex designs and down to single-digit nanometre dimensions over 200 mm wafer scale. Compatible with semiconductor industry standard complementary metal-oxide semiconductor logic circuit fabrication processes, this strategy extracts a patterned sacrificial silicon layer through hundreds of millions of nanoscale vent holes on each chip by gas-phase Xenon difluoride etching. Using single-molecule fluorescence imaging, we demonstrate these sacrificial nanofluidic chips can function to controllably and completely stretch lambda DNA in a two-dimensional nanofluidic network comprising channels and pillars. The flexible nanofluidic structure design, wafer-scale fabrication, single-digit nanometre channels, reliable fluidic sealing and low thermal budget make our strategy a potentially universal approach to integrating functional planar nanofluidic systems with logic circuits for lab-on-a-chip applications.

  6. Wafer-scale single-domain-like graphene by defect-selective atomic layer deposition of hexagonal ZnO

    Science.gov (United States)

    Park, Kyung Sun; Kim, Sejoon; Kim, Hongbum; Kwon, Deokhyeon; Koo Lee, Yong-Eun; Min, Sung-Wook; Im, Seongil; Choi, Hyoung Joon; Lim, Seulky; Shin, Hyunjung; Koo, Sang Man; Sung, Myung Mo

    2015-10-01

    Large-area graphene films produced by means of chemical vapor deposition (CVD) are polycrystalline and thus contain numerous grain boundaries that can greatly degrade their performance and produce inhomogeneous properties. A better grain boundary engineering in CVD graphene is essential to realize the full potential of graphene in large-scale applications. Here, we report a defect-selective atomic layer deposition (ALD) for stitching grain boundaries of CVD graphene with ZnO so as to increase the connectivity between grains. In the present ALD process, ZnO with a hexagonal wurtzite structure was selectively grown mainly on the defect-rich grain boundaries to produce ZnO-stitched CVD graphene with well-connected grains. For the CVD graphene film after ZnO stitching, the inter-grain mobility is notably improved with only a little change in the free carrier density. We also demonstrate how ZnO-stitched CVD graphene can be successfully integrated into wafer-scale arrays of top-gated field-effect transistors on 4-inch Si and polymer substrates, revealing remarkable device-to-device uniformity.Large-area graphene films produced by means of chemical vapor deposition (CVD) are polycrystalline and thus contain numerous grain boundaries that can greatly degrade their performance and produce inhomogeneous properties. A better grain boundary engineering in CVD graphene is essential to realize the full potential of graphene in large-scale applications. Here, we report a defect-selective atomic layer deposition (ALD) for stitching grain boundaries of CVD graphene with ZnO so as to increase the connectivity between grains. In the present ALD process, ZnO with a hexagonal wurtzite structure was selectively grown mainly on the defect-rich grain boundaries to produce ZnO-stitched CVD graphene with well-connected grains. For the CVD graphene film after ZnO stitching, the inter-grain mobility is notably improved with only a little change in the free carrier density. We also

  7. SCIL nanoimprint solutions: high-volume soft NIL for wafer scale sub-10nm resolution

    Science.gov (United States)

    Voorkamp, R.; Verschuuren, M. A.; van Brakel, R.

    2016-10-01

    Nano-patterning materials and surfaces can add unique functionalities and properties which cannot be obtained in bulk or micro-structured materials. Examples range from hetro-epitaxy of semiconductor nano-wires to guiding cell expression and growth on medical implants. [1] Due to the cost and throughput requirements conventional nano-patterning techniques such as deep UV lithography (cost and flat substrate demands) and electron-beam lithography (cost, throughput) are not an option. Self-assembly techniques are being considered for IC manufacturing, but require nano-sized guiding patterns, which have to be fabricated in any case.[2] Additionally, the self-assembly process is highly sensitive to the environment and layer thickness, which is difficult to control on non-flat surfaces such as PV silicon wafers or III/V substrates. Laser interference lithography can achieve wafer scale periodic patterns, but is limited by the throughput due to intensity of the laser at the pinhole and only regular patterns are possible where the pattern fill fraction cannot be chosen freely due to the interference condition.[3] Nanoimprint lithography (NIL) is a promising technology for the cost effective fabrication of sub-micron and nano-patterns on large areas. The challenges for NIL are related to the technique being a contact method where a stamp which holds the patterns is required to be brought into intimate contact with the surface of the product. In NIL a strong distinction is made between the type of stamp used, either rigid or soft. Rigid stamps are made from patterned silicon, silica or plastic foils and are capable of sub-10nm resolution and wafer scale patterning. All these materials behave similar at the micro- to nm scale and require high pressures (5 - 50 Bar) to enable conformal contact to be made on wafer scales. Real world conditions such as substrate bow and particle contaminants complicate the use of rigid stamps for wafer scale areas, reducing stamp lifetime and

  8. Graphene and thin-film semiconductor heterojunction transistors integrated on wafer scale for low-power electronics.

    Science.gov (United States)

    Heo, Jinseong; Byun, Kyung-Eun; Lee, Jaeho; Chung, Hyun-Jong; Jeon, Sanghun; Park, Seongjun; Hwang, Sungwoo

    2013-01-01

    Graphene heterostructures in which graphene is combined with semiconductors or other layered 2D materials are of considerable interest, as a new class of electronic devices has been realized. Here we propose a technology platform based on graphene-thin-film-semiconductor-metal (GSM) junctions, which can be applied to large-scale and power-efficient electronics compatible with a variety of substrates. We demonstrate wafer-scale integration of vertical field-effect transistors (VFETs) based on graphene-In-Ga-Zn-O (IGZO)-metal asymmetric junctions on a transparent 150 × 150 mm(2) glass. In this system, a triangular energy barrier between the graphene and metal is designed by selecting a metal with a proper work function. We obtain a maximum current on/off ratio (Ion/Ioff) up to 10(6) with an average of 3010 over 2000 devices under ambient conditions. For low-power logic applications, an inverter that combines complementary n-type (IGZO) and p-type (Ge) devices is demonstrated to operate at a bias of only 0.5 V.

  9. Wafer-scale integrated micro-supercapacitors on an ultrathin and highly flexible biomedical platform.

    Science.gov (United States)

    Maeng, Jimin; Meng, Chuizhou; Irazoqui, Pedro P

    2015-02-01

    We present wafer-scale integrated micro-supercapacitors on an ultrathin and highly flexible parylene platform, as progress toward sustainably powering biomedical microsystems suitable for implantable and wearable applications. All-solid-state, low-profile (microsystem. The system discharging rate is shown to improve by ~17 times in the presence of the integrated micro-supercapacitors. This result suggests that the integrated micro-supercapacitor technology described herein is a promising strategy for sustainably powering biomedical microsystems dedicated to implantable and wearable applications.

  10. Si nanowire directly grown on a liquid metal substrate—towards wafer scale transferable nanowire arrays with improved visible-light sterilization

    Science.gov (United States)

    Wang, Hui; Wang, Jian-Tao; Ou, Xue-Mei; Lee, Chun-Sing; Zhang, Xiao-Hong

    2014-04-01

    Integrating vertically aligned nanowires (NWs) on a functional substrate is important for the application of NWs in wafer scale assemblies and functional devices. However, vertically aligned NWs via the current epitaxial growth route can only be prepared on crystalline wafers. A convenient method is thus presented to overcome NW substrate limitations. Liquid metal is proposed to serve as a substrate for the initial growth of vertically aligned NWs. NWs could then be harvested from the growth substrate and integrated with functional substrates. Fabricated vertically aligned silicon NWs (SiNWs) were grown on molten Sn and then integrated into a flexible transparent poly(dimethylsiloxane) film to obtain a SiNW/functional substrate device. The device showed enhanced visible-light absorption ability and refreshable visible-light bactericidal activities with a bacterial reduction rate of close to 100%, indicating that growth with molten metal as a substrate could be a promising approach for extending the function and application of NWs.

  11. Microphotonic devices for compact planar lightwave circuits and sensor systems

    Science.gov (United States)

    Cardenas Gonzalez, Jaime

    2005-07-01

    Higher levels of integration in planar lightwave circuits and sensor systems can reduce fabrication costs and broaden viable applications for optical network and sensor systems. For example, increased integration and functionality can lead to sensor systems that are compact enough for easy transport, rugged enough for field applications, and sensitive enough even for laboratory applications. On the other hand, more functional and compact planar lightwave circuits can make optical networks components less expensive for the metro and access markets in urban areas and allow penetration of fiber to the home. Thus, there is an important area of opportunity for increased integration to provide low cost, compact solutions in both network components and sensor systems. In this dissertation, a novel splitting structure for microcantilever deflection detection is introduced. The splitting structure is designed so that its splitting ratio is dependent on the vertical position of the microcantilever. With this structure, microcantilevers sensitized to detect different analytes or biological agents can be integrated into an array on a single chip. Additionally, the integration of a depolarizer into the optoelectronic integrated circuit in an interferometric fiber optic gyroscope is presented as a means for cost reduction. The savings come in avoiding labor intensive fiber pigtailing steps by permitting batch fabrication of these components. In particular, this dissertation focuses on the design of the waveguides and polarization rotator, and the impact of imperfect components on the performance of the depolarizer. In the area of planar lightwave circuits, this dissertation presents the development of a fabrication process for single air interface bends (SAIBs). SAIBs can increase integration by reducing the area necessary to make a waveguide bend. Fabrication and measurement of a 45° SAIB with a bend efficiency of 93.4% for TM polarization and 92.7% for TE polarization are presented.

  12. Sidewall patterning—a new wafer-scale method for accurate patterning of vertical silicon structures

    Science.gov (United States)

    Westerik, P. J.; Vijselaar, W. J. C.; Berenschot, J. W.; Tas, N. R.; Huskens, J.; Gardeniers, J. G. E.

    2018-01-01

    For the definition of wafer scale micro- and nanostructures, in-plane geometry is usually controlled by optical lithography. However, options for precisely patterning structures in the out-of-plane direction are much more limited. In this paper we present a versatile self-aligned technique that allows for reproducible sub-micrometer resolution local modification along vertical silicon sidewalls. Instead of optical lithography, this method makes smart use of inclined ion beam etching to selectively etch the top parts of structures, and controlled retraction of a conformal layer to define a hard mask in the vertical direction. The top, bottom or middle part of a structure could be selectively exposed, and it was shown that these exposed regions can, for example, be selectively covered with a catalyst, doped, or structured further.

  13. Wafer-scale thin encapsulated two-dimensional nanochannels and its application toward visualization of single molecules

    NARCIS (Netherlands)

    Hoang Thi Hanh, H.T.H.; Tong, H.D.; Segers-Nolten, Gezina M.J.; Tas, Niels Roelof; Subramaniam, Vinod; Elwenspoek, Michael Curt

    2012-01-01

    We present a new and simple approach to fabricate wafer-scale, thin encapsulated, two-dimensional nanochannels by using conventional surface-micromachining technology and thin-film evaporation. The key steps to the realization of two-dimensional nanochannels are a fine etching of a sacrificial layer

  14. Wafer-scale thin encapsulated two-dimensional nanochannels and its application toward visualization of single molecules.

    NARCIS (Netherlands)

    Hoang, H.T.; Tong, H.D.; Segers-Nolten, I.M.; Tas, N.R.; Subramaniam, V.; Elwenspoek, M.C.

    2012-01-01

    We present a new and simple approach to fabricate wafer-scale, thin encapsulated, two-dimensional nanochannels by using conventional surface-micromachining technology and thin-film evaporation. The key steps to the realization of two-dimensional nanochannels are a fine etching of a sacrificial layer

  15. Uniformity study of wafer-scale InP-to-silicon hybrid integration

    Energy Technology Data Exchange (ETDEWEB)

    Liang, Di; Bowers, John E. [University of California, Department of Electrical and Computer Engineering, Santa Barbara, CA (United States); Chapman, David C.; Oakley, Douglas C.; Napoleone, Tony; Juodawlkis, Paul W. [Massachusetts Institute of Technology, Lincoln Laboratory, Lexington, MA (United States); Li, Youli [University of California, Materials Research Laboratory, Santa Barbara, CA (United States); Brubaker, Chad; Mann, Carl [EV Group, Tempe, AZ (United States); Bar, Hanan; Raday, Omri [Intel Corporation, Jerusalem (Israel)

    2011-04-15

    In this paper we study the uniformity of up to 150 mm in diameter wafer-scale III-V epitaxial transfer to the Si-on-insulator substrate through the O{sub 2} plasma-enhanced low-temperature (300 C) direct wafer bonding. Void-free bonding is demonstrated by the scanning acoustic microscopy with sub-{mu}m resolution. The photoluminescence (PL) map shows less than 1 nm change in average peak wavelength, and even improved peak intensity (4% better) and full width at half maximum (41% better) after 150 mm in diameter epitaxial transfer. Small and uniformly distributed residual strain in all sizes of bonding, which is measured by high-resolution X-ray diffraction Omega-2Theta mapping, and employment of a two-period InP-InGaAsP superlattice at the bonding interface contributes to the improvement of PL response. Preservation of multiple quantum-well integrity is also verified by high-resolution transmission electron microscopy. (orig.)

  16. Fabrication of WS2/GaN p-n Junction by Wafer-Scale WS2 Thin Film Transfer

    Science.gov (United States)

    Yu, Yang; Fong, Patrick W. K.; Wang, Shifeng; Surya, Charles

    2016-01-01

    High quality wafer-scale free-standing WS2 grown by van der Waals rheotaxy (vdWR) using Ni as a texture promoting layer is reported. The microstructure of vdWR grown WS2 was significantly modified from mixture of crystallites with their c-axes both parallel to (type I) and perpendicular to (type II) the substrate to large type II crystallites. Wafer-scale transfer of vdWR grown WS2 onto different substrates by an etching-free technique was demonstrated for the first time that utilized the hydrophobic property of WS2 and hydrophilic property of sapphire. Our results show that vdWR is a reliable technique to obtain type-II textured crystallites in WS2, which is the key factor for the wafer-scale etching-free transfer. The transferred films were found to be free of observable wrinkles, cracks, or polymer residues. High quality p-n junctions fabricated by room-temperature transfer of the p-type WS2 onto an n-type GaN was demonstrated with a small leakage current density of 29.6 μA/cm2 at −1 V which shows superior performances compared to the directly grown WS2/GaN heterojunctions. PMID:27897210

  17. Field-effect transistors based on wafer-scale, highly uniform few-layer p-type WSe2

    Science.gov (United States)

    Campbell, Philip M.; Tarasov, Alexey; Joiner, Corey A.; Tsai, Meng-Yen; Pavlidis, Georges; Graham, Samuel; Ready, W. Jud; Vogel, Eric M.

    2016-01-01

    The synthesis of few-layer tungsten diselenide (WSe2) via chemical vapor deposition typically results in highly non-uniform thickness due to nucleation initiated growth of triangular domains. In this work, few-layer p-type WSe2 with wafer-scale thickness and electrical uniformity is synthesized through direct selenization of thin films of e-beam evaporated W on SiO2 substrates. Raman maps over a large area of the substrate show small variations in the main peak position, indicating excellent thickness uniformity across several square centimeters. Additionally, field-effect transistors fabricated from the wafer-scale WSe2 films demonstrate uniform electrical performance across the substrate. The intrinsic field-effect mobility of the films at a carrier concentration of 3 × 1012 cm-2 is 10 cm2 V-1 s-1. The unprecedented uniformity of the WSe2 on wafer-scale substrates provides a substantial step towards producing manufacturable materials that are compatible with conventional semiconductor fabrication processes.

  18. Design and fabrication of the periodical structures based on grooved Si for middle infrared microphotonics

    Energy Technology Data Exchange (ETDEWEB)

    Tolmachev, V. [Ioffe Physico-Technical Institute, 26 Polytekhnicheskaya, St Petersburg 194021 (Russian Federation); Department of Electronic and Electrical Engineering, University of Dublin, Trinity College, Dublin 2 (Ireland); Astrova, E.; Pilyugina, J. [Ioffe Physico-Technical Institute, 26 Polytekhnicheskaya, St Petersburg 194021 (Russian Federation); Perova, T.; Moore, A. [Department of Electronic and Electrical Engineering, University of Dublin, Trinity College, Dublin 2 (Ireland)

    2005-06-01

    In this work we report on design, fabrication and characterisation of different structures based on grooved Si which can be served as an optical elements for infrared microphotonics. (copyright 2005 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  19. Bottom-Up Nano-heteroepitaxy of Wafer-Scale Semipolar GaN on (001) Si

    KAUST Repository

    Hus, Jui Wei

    2015-07-15

    Semipolar {101¯1} InGaN quantum wells are grown on (001) Si substrates with an Al-free buffer and wafer-scale uniformity. The novel structure is achieved by a bottom-up nano-heteroepitaxy employing self-organized ZnO nanorods as the strain-relieving layer. This ZnO nanostructure unlocks the problems encountered by the conventional AlN-based buffer, which grows slowly and contaminates the growth chamber. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  20. Single crystal monolayer MoS2 triangles with wafer-scale spatial uniformity by MoO3 pre-deposited chemical vapor deposition

    Science.gov (United States)

    Cheng, Zhaofang; Xia, Minggang; Hu, Ruixue; Liang, Chunping; Liang, Gongying; Zhang, Shengli

    2017-12-01

    Two-dimensional transition metal dichalcogenides (TMDs) show a potential application in photoelectric device due to their excellent electrical and optical properties. Here, we report that the MoO3 pre-deposited chemical vapor deposition (CVD) is used to synthesize single crystal monolayer MoS2 triangles on 4 in. wafer. We found that the wafer-scale uniformity of MoS2 can be greatly improved by regularly depositing MoO3 particles on substrate before CVD growth. Therefore, a piece of cleanroom wiper was used as a template for implementing precise control of MoO3 pre-deposition. We found that the optimal deposition size of MoO3 particles and the distance between MoO3 particles are about 15 μm and 0.9 mm, respectively. Both microscopic and spectroscopic characterization results demonstrate that the as-grown MoS2 is highly uniform in space distribution and crystal structure. The electronic performance of MoS2 synthesized by our method is comparable to or even slightly better than those in common CVD samples. The role of MoO3 pre-deposition is not only to effectively control the MoS2 nucleation density but also to overcome poor diffusion of MoO3 source. Our method is expected to accelerate the industrial synthesis of the atomically thin TMD materials.

  1. Wafer-scale fabrication and growth dynamics of suspended graphene nanoribbon arrays

    National Research Council Canada - National Science Library

    Suzuki, Hiroo; Kaneko, Toshiro; Shibuta, Yasushi; Ohno, Munekazu; Maekawa, Yuki; Kato, Toshiaki

    2016-01-01

    Adding a mechanical degree of freedom to the electrical and optical properties of atomically thin materials can provide an excellent platform to investigate various optoelectrical physics and devices...

  2. Plasma-Induced Wafer-Scale Self-Assembly of Silver Nanoparticles and Application to Biochemical Sensing

    Directory of Open Access Journals (Sweden)

    Yunbo Shi

    2015-06-01

    Full Text Available In this work, the wafer-scale silver nanoparticles fabricated by a self-assembly method was demonstrated based on a magnetron sputtering and plasma treatment process. Silver nanoparticles of different sizes and shapes were prepared, and the effects of the plasma treatment time, plasma gas composition, and power were systematically investigated to develop a method for low-cost and large-scale fabrication of silver nanoparticles. Furthermore, the surface-enhanced Raman scattering experiments: crystal violet, as the probe, was absorbed on the silver nanoparticles film of different size and density, and get the phenomena of surface-enhanced Raman scattering and surface-enhanced fluorescence. The results show that the proposed technique provides a rapid method for the fabrication of silver nanomaterial; the method is adaptable to large-scale production and is compatible with the fabrication of other materials and biosensors.

  3. Terahertz wafer-scale mobility mapping of graphene on insulating substrates without a gate

    DEFF Research Database (Denmark)

    Buron, Jonas Due; Mackenzie, David M. A.; Petersen, Dirch Hjorth

    2015-01-01

    carriers and these parameters are directly compared to van der Pauw device measurements on the same wafer. The technique is compatible with all substrate materials that exhibit a reasonably low absorption coefficient for terahertz radiation. This includes many materials used for transferring CVD graphene...

  4. Wafer-scale controlled exfoliation of metal organic vapor phase epitaxy grown InGaN/GaN multi quantum well structures using low-tack two-dimensional layered h-BN

    Energy Technology Data Exchange (ETDEWEB)

    Ayari, Taha; Li, Xin; Voss, Paul L.; Ougazzaden, Abdallah, E-mail: aougazza@georgiatech-metz.fr [School of Electrical and Computer Engineering, Georgia Institute of Technology, Atlanta, Georgia 30332 (United States); Georgia Tech Lorraine, UMI 2958, Georgia Tech-CNRS, 57070 Metz (France); Sundaram, Suresh; El Gmili, Youssef [Georgia Tech Lorraine, UMI 2958, Georgia Tech-CNRS, 57070 Metz (France); Salvestrini, Jean Paul [Georgia Tech Lorraine, UMI 2958, Georgia Tech-CNRS, 57070 Metz (France); Université de Lorraine, LMOPS, EA 4423, 57070 Metz (France)

    2016-04-25

    Recent advances in epitaxial growth have led to the growth of III-nitride devices on 2D layered h-BN. This advance has the potential for wafer-scale transfer to arbitrary substrates, which could improve the thermal management and would allow III-N devices to be used more flexibly in a broader range of applications. We report wafer scale exfoliation of a metal organic vapor phase epitaxy grown InGaN/GaN Multi Quantum Well (MQW) structure from a 5 nm thick h-BN layer that was grown on a 2-inch sapphire substrate. The weak van der Waals bonds between h-BN atomic layers break easily, allowing the MQW structure to be mechanically lifted off from the sapphire substrate using a commercial adhesive tape. This results in the surface roughness of only 1.14 nm on the separated surface. Structural characterizations performed before and after the lift-off confirm the conservation of structural properties after lift-off. Cathodoluminescence at 454 nm was present before lift-off and 458 nm was present after. Electroluminescence near 450 nm from the lifted-off structure has also been observed. These results show that the high crystalline quality ultrathin h-BN serves as an effective sacrificial layer—it maintains performance, while also reducing the GaN buffer thickness and temperature ramps as compared to a conventional two-step growth method. These results support the use of h-BN as a low-tack sacrificial underlying layer for GaN-based device structures and demonstrate the feasibility of large area lift-off and transfer to any template, which is important for industrial scale production.

  5. Wafer scale fabrication of carbon nanotube thin film transistors with high yield

    Energy Technology Data Exchange (ETDEWEB)

    Tian, Boyuan; Liang, Xuelei, E-mail: liangxl@pku.edu.cn, E-mail: ssxie@iphy.ac.cn; Yan, Qiuping; Zhang, Han; Xia, Jiye; Dong, Guodong; Peng, Lianmao [Key Laboratory for the Physics and Chemistry of Nanodevices and Department of Electronics, Peking University, Beijing 100871 (China); Xie, Sishen, E-mail: liangxl@pku.edu.cn, E-mail: ssxie@iphy.ac.cn [Key Laboratory for the Physics and Chemistry of Nanodevices and Department of Electronics, Peking University, Beijing 100871 (China); Institute of Physics, Chinese Academy of Sciences, Beijing 100190 (China)

    2016-07-21

    Carbon nanotube thin film transistors (CNT-TFTs) are promising candidates for future high performance and low cost macro-electronics. However, most of the reported CNT-TFTs are fabricated in small quantities on a relatively small size substrate. The yield of large scale fabrication and the performance uniformity of devices on large size substrates should be improved before the CNT-TFTs reach real products. In this paper, 25 200 devices, with various geometries (channel width and channel length), were fabricated on 4-in. size ridged and flexible substrates. Almost 100% device yield were obtained on a rigid substrate with high out-put current (>8 μA/μm), high on/off current ratio (>10{sup 5}), and high mobility (>30 cm{sup 2}/V·s). More importantly, uniform performance in 4-in. area was achieved, and the fabrication process can be scaled up. The results give us more confidence for the real application of the CNT-TFT technology in the near future.

  6. Wafer-scale growth of large arrays of perovskite microplate crystals for functional electronics and optoelectronics.

    Science.gov (United States)

    Wang, Gongming; Li, Dehui; Cheng, Hung-Chieh; Li, Yongjia; Chen, Chih-Yen; Yin, Anxiang; Zhao, Zipeng; Lin, Zhaoyang; Wu, Hao; He, Qiyuan; Ding, Mengning; Liu, Yuan; Huang, Yu; Duan, Xiangfeng

    2015-10-01

    Methylammonium lead iodide perovskite has attracted intensive interest for its diverse optoelectronic applications. However, most studies to date have been limited to bulk thin films that are difficult to implement for integrated device arrays because of their incompatibility with typical lithography processes. We report the first patterned growth of regular arrays of perovskite microplate crystals for functional electronics and optoelectronics. We show that large arrays of lead iodide microplates can be grown from an aqueous solution through a seeded growth process and can be further intercalated with methylammonium iodide to produce perovskite crystals. Structural and optical characterizations demonstrate that the resulting materials display excellent crystalline quality and optical properties. We further show that perovskite crystals can be selectively grown on prepatterned electrode arrays to create independently addressable photodetector arrays and functional field effect transistors. The ability to grow perovskite microplates and to precisely place them at specific locations offers a new material platform for the fundamental investigation of the electronic and optical properties of perovskite materials and opens a pathway for integrated electronic and optoelectronic systems.

  7. Atomic layer lithography of wafer-scale nanogap arrays for extreme confinement of electromagnetic waves.

    Science.gov (United States)

    Chen, Xiaoshu; Park, Hyeong-Ryeol; Pelton, Matthew; Piao, Xianji; Lindquist, Nathan C; Im, Hyungsoon; Kim, Yun Jung; Ahn, Jae Sung; Ahn, Kwang Jun; Park, Namkyoo; Kim, Dai-Sik; Oh, Sang-Hyun

    2013-01-01

    Squeezing light through nanometre-wide gaps in metals can lead to extreme field enhancements, nonlocal electromagnetic effects and light-induced electron tunnelling. This intriguing regime, however, has not been readily accessible to experimentalists because of the lack of reliable technology to fabricate uniform nanogaps with atomic-scale resolution and high throughput. Here we introduce a new patterning technology based on atomic layer deposition and simple adhesive-tape-based planarization. Using this method, we create vertically oriented gaps in opaque metal films along the entire contour of a millimetre-sized pattern, with gap widths as narrow as 9.9 Å, and pack 150,000 such devices on a 4-inch wafer. Electromagnetic waves pass exclusively through the nanogaps, enabling background-free transmission measurements. We observe resonant transmission of near-infrared waves through 1.1-nm-wide gaps (λ/1,295) and measure an effective refractive index of 17.8. We also observe resonant transmission of millimetre waves through 1.1-nm-wide gaps (λ/4,000,000) and infer an unprecedented field enhancement factor of 25,000.

  8. Wafer-scale fabrication of polymer-based microdevices via injection molding and photolithographic micropatterning protocols.

    Science.gov (United States)

    Lee, Dae-Sik; Yang, Haesik; Chung, Kwang-Hyo; Pyo, Hyeon-Bong

    2005-08-15

    Because of their broad applications in biomedical analysis, integrated, polymer-based microdevices incorporating micropatterned metallic and insulating layers are significant in contemporary research. In this study, micropatterns for temperature sensing and microelectrode sets for electroanalysis have been implemented on an injection-molded thin polymer membrane by employing conventional semiconductor processing techniques (i.e., standard photolithographic methods). Cyclic olefin copolymer (COC) is chosen as the polymer substrate because of its high chemical and thermal stability. A COC 5-in. wafer (1-mm thickness) is manufactured using an injection molding method, in which polymer membranes (approximately 130 microm thick and 3 mm x 6 mm in area) are implemented simultaneously in order to reduce local thermal mass around micropatterned heaters and temperature sensors. The highly polished surface (approximately 4 nm within 40 microm x 40 microm area) of the fabricated COC wafer as well as its good resistance to typical process chemicals makes it possible to use the standard photolithographic and etching protocols on the COC wafer. Gold micropatterns with a minimum 5-microm line width are fabricated for making microheaters, temperature sensors, and microelectrodes. An insulating layer of aluminum oxide (Al2O3) is prepared at a COC-endurable low temperature (approximately 120 degrees C) by using atomic layer deposition and micropatterning for the electrode contacts. The fabricated microdevice for heating and temperature sensing shows improved performance of thermal isolation, and microelectrodes display good electrochemical performances for electrochemical sensors. Thus, this novel 5-in. wafer-level microfabrication method is a simple and cost-effective protocol to prepare polymer substrate and demonstrates good potential for application to highly integrated and miniaturized biomedical devices.

  9. Atomic mechanism for the growth of wafer-scale single-crystal graphene: theoretical perspective and scanning tunneling microscopy investigations

    Science.gov (United States)

    Niu, Tianchao; Zhang, Jialin; Chen, Wei

    2017-12-01

    Chemical vapor deposition (CVD) is the most promising approach for producing low-cost, high-quality, and large area graphene. Revealing the graphene growth mechanism at the atomic-scale is of great importance for realizing single crystal graphene (SCG) over wafer scale. Density functional theoretical (DFT) calculations are playing an increasingly important role in revealing the structure of the most stable carbon species, understanding the evolution processes, and disclosing the active sites. Scanning tunneling microscopy (STM) is a powerful surface characterization tool to illustrate the real space distribution and atomic structures of growth intermediates during the CVD process. Combining them together can provide valuable information to improve the atomically controlled growth of SCG. Starting from a basic concept of the substrate effect on realizing SCG, this review covers the progress made in theoretical investigations on various carbon species during graphene growth on different transition metal substrates, in the STM study of the structural intermediates on transition metal surfaces, and in synthesizing graphene nanoribbons with atomic-precise width and edge structure, ending with a perspective on the future development of 2D materials beyond graphene.

  10. Simple, Fast, and Cost-Effective Fabrication of Wafer-Scale Nanohole Arrays on Silicon for Antireflection

    Directory of Open Access Journals (Sweden)

    Di Di

    2014-01-01

    Full Text Available A simple, fast, and cost-effective method was developed in this paper for the high-throughput fabrication of nanohole arrays on silicon (Si, which is utilized for antireflection. Wafer-scale polystyrene (PS monolayer colloidal crystal was developed as templates by spin-coating method. Metallic shadow mask was prepared by lifting off the oxygen etched PS beads from the deposited chromium film. Nanohole arrays were fabricated by Si dry etching. A series of nanohole arrays were fabricated with the similar diameter but with different depth. It is found that the maximum depth of the Si-hole was determined by the diameter of the Cr-mask. The antireflection ability of these Si-hole arrays was investigated. The results show that the reflection decreases with the depth of the Si-hole. The deepest Si-hole arrays show the best antireflection ability (reflection 600 nm, which was about 28 percent of the nonpatterned silicon wafer’s reflection. The proposed method has the potential for high-throughput fabrication of patterned Si wafer, and the low reflectivity allows the application of these wafers in crystalline silicon solar cells.

  11. Wafer Scale Distributed Radio

    Science.gov (United States)

    2009-07-01

    Rload LLg *Lg*Lg*g*Lg*g*L CWk*Ck*Wk*k*Ck*k*W Ibiask*Ibiask*k*Ibias Figure 3.11: Lumped element model of a distributed amplifier. To facilitate the design...5.26) , where Z0 ≈ √ B C . By computing γ with a real part into the voltage equation , Fig. 5.7 is generated and describes the skew related to the clock... equation , we can derive: ∆ flock = f0 2Q Ain j A (5.34) with Ain j and A, the relative amplitude of the injecting signal and the oscillator signal, both

  12. Versatile Wafer-Scale Technique for the Formation of Ultrasmooth and Thickness-Controlled Graphene Oxide Films Based on Very Large Flakes.

    Science.gov (United States)

    Azevedo, Joël; Campidelli, Stéphane; He, Delong; Cornut, Renaud; Bertucchi, Michael; Sorgues, Sébastien; Benattar, Jean-Jacques; Colbeau-Justin, Christophe; Derycke, Vincent

    2015-09-30

    We present a new strategy to form thickness-adjusted and ultrasmooth films of very large and unwrinkled graphene oxide (GO) flakes through the transfer of both hemispherical and vertical water films stabilized by surfactants. With its versatility in terms of substrate type (including flexible organic substrates) and in terms of flake density (from isolated flakes to continuous and multilayer films), this wafer-scale assembly technique is adapted to a broad range of experiments involving GO and rGO (reduced graphene oxide). We illustrate its use through the evaluation of transparent rGO electrodes.

  13. Laser ablation of micro-photonic structures for efficient light collection and distribution

    Science.gov (United States)

    Shang, Xiaobing; Desmet, Andres; De Smet, Jelle; Joshi, Pankaj; Cuypers, Dieter; Van Put, Steven; Van Steenberge, Geert; Vervaeke, Michael; Thienpont, Hugo; De Smet, Herbert

    2015-06-01

    In this work we report the fabrication of polymer micro-photonic gratings for use in liquid-crystal based actively tunable electro-optic components. The gratings are produced by moving the sample surface sideways across a perpendicularly impinging KrF excimer laser beam (λ  =  248 nm), which is shaped by specially designed triangular and trapezoidal masks. To obtain correctly dimensioned and smooth grating surfaces, different materials (SU-8, polycarbonate, Epoclad and Epocore) are subjected to the laser ablation with optimized laser processing parameters. The resulting grating structures on Epocore exhibit the best surface roughness and dimensional fidelity. Optionally, spacers for maintaining the cell gap of the superimposed liquid crystal layer can also be fabricated in the same process. Two different methods were demonstrated: overlapping ablation and double mask ablation. Micro-grating structures were produced that deflect a monochromatic (543 nm) laser beam to the theoretically predicted 11th order with an angle of 7°.

  14. Investigation of dielectric substrates on electrical and optical performance of wafer-scale graphene using non-contact methods

    Science.gov (United States)

    Wang, Dong; Ning, Jing; Zhang, Jincheng; Guo, Lixin; Hao, Yue

    2017-10-01

    Here we systemically discussed the influence of dielectric substrates on the surface morphology, electrical and optical performance of transferred graphene. The electrical properties were investigated using a microwave-probing technique without metal-graphene contact. We found that a complex mechanism governed the influence of the surface properties of the dielectric substrates, such as morphology, hydrophilicity, crystallinity, and polarization, on the performance of the graphene. We also found that graphene on r-Al2O3 was more effective for graphene-based devices with a high carrier mobility of ˜5000 cm2 V-1 s-1. This provides a new method to choose the most suitable substrate for fabricating graphene-based devices.

  15. Wafer-scaled monolayer WO3 windows ultra-sensitive, extremely-fast and stable UV-A photodetection

    Science.gov (United States)

    Hai, Zhenyin; Akbari, Mohammad Karbalaei; Xue, Chenyang; Xu, Hongyan; Hyde, Lachlan; Zhuiykov, Serge

    2017-05-01

    The monolayer WO3-based UV-A photodetectors, fabricated by atomic layer deposition (ALD) technique at the large area of SiO2/Si wafer, have demonstrated vastly improved functional capabilities: extremely fast response time of less than 40 μs and photoresponsivity reaching of ∼0.329 A W-1. Their ultrafast photoresponse time is at least 400-fold improvement over the previous reports for any other WO3-based UV photodetectors that have ever been fabricated, and significantly faster than most of other photodetectors based on two-dimensional (2D) nanomaterials reported-to-date. Moreover, their measured long-term stability exceeds more than 200 cycles without any visible degradation. The ALD-deposited WO3 monolayer has also exhibited wider bandgap of 3.53 eV and the UV-A photodetector based on it is environmentally friendly, highly reliable, with excellent reproducibility and long-term stability. Thus, the shift to mono-layered semiconductors, which possess completely new quantum-confined effects, has the greatest potential in creating a new class of nano-materials, which in return windows new functional opportunities for various opto-electronic instruments built on semiconductor monolayer and, more importantly, can result in new strategy for fabrication highly-flexible, inexpensive and extremely-sensitive devices. This strategy also opens up the great opportunities for industrialization and commercialization of the photodetectors and other optoelectronic devices based on monolayer or few-layered 2D nanomaterials.

  16. Graphene nanoribbon field-effect transistors on wafer-scale epitaxial graphene on SiC substrates

    Directory of Open Access Journals (Sweden)

    Wan Sik Hwang

    2015-01-01

    Full Text Available We report the realization of top-gated graphene nanoribbon field effect transistors (GNRFETs of ∼10 nm width on large-area epitaxial graphene exhibiting the opening of a band gap of ∼0.14 eV. Contrary to prior observations of disordered transport and severe edge-roughness effects of graphene nanoribbons (GNRs, the experimental results presented here clearly show that the transport mechanism in carefully fabricated GNRFETs is conventional band-transport at room temperature and inter-band tunneling at low temperature. The entire space of temperature, size, and geometry dependent transport properties and electrostatics of the GNRFETs are explained by a conventional thermionic emission and tunneling current model. Our combined experimental and modeling work proves that carefully fabricated narrow GNRs behave as conventional semiconductors and remain potential candidates for electronic switching devices.

  17. X-ray performance of a wafer-scale CMOS flat panel imager for applications in medical imaging and nondestructive testing

    Energy Technology Data Exchange (ETDEWEB)

    Cha, Bo Kyung, E-mail: goldrain99@kaist.ac.kr [Advanced Medical Device Research Center, Korea Electrotechnology Research Institute, Ansan (Korea, Republic of); Jeon, Seongchae [Advanced Medical Device Research Center, Korea Electrotechnology Research Institute, Ansan (Korea, Republic of); Seo, Chang-Woo [Department of Radiological Science, Yonsei University, Gangwon-do 220-710 (Korea, Republic of)

    2016-09-21

    This paper presents a wafer-scale complementary metal-oxide semiconductor (CMOS)-based X-ray flat panel detector for medical imaging and nondestructive testing applications. In this study, our proposed X-ray CMOS flat panel imager has been fabricated by using a 0.35 µm 1-poly/4-metal CMOS process. The pixel size is 100 µm×100 µm and the pixel array format is 1200×1200 pixels, which provide a field-of-view (FOV) of 120mm×120 mm. The 14.3-bit extended counting analog-to digital converter (ADC) with built-in binning mode was used to reduce the area and simultaneously improve the image resolution. The different screens such as thallium-doped CsI (CsI:Tl) and terbium gadolinium oxysulfide (Gd{sub 2}O{sub 2}S:Tb) scintillators were used as conversion materials for X-rays to visible light photons. The X-ray imaging performance such as X-ray sensitivity as a function of X-ray exposure dose, spatial resolution, image lag and X-ray images of various objects were measured under practical medical and industrial application conditions. This paper results demonstrate that our prototype CMOS-based X-ray flat panel imager has the significant potential for medical imaging and non-destructive testing (NDT) applications with high-resolution and high speed rate.

  18. Thickness scaling of atomic-layer-deposited HfO2 films and their application to wafer-scale graphene tunnelling transistors.

    Science.gov (United States)

    Jeong, Seong-Jun; Gu, Yeahyun; Heo, Jinseong; Yang, Jaehyun; Lee, Chang-Seok; Lee, Min-Hyun; Lee, Yunseong; Kim, Hyoungsub; Park, Seongjun; Hwang, Sungwoo

    2016-02-10

    The downscaling of the capacitance equivalent oxide thickness (CET) of a gate dielectric film with a high dielectric constant, such as atomic layer deposited (ALD) HfO2, is a fundamental challenge in achieving high-performance graphene-based transistors with a low gate leakage current. Here, we assess the application of various surface modification methods on monolayer graphene sheets grown by chemical vapour deposition to obtain a uniform and pinhole-free ALD HfO2 film with a substantially small CET at a wafer scale. The effects of various surface modifications, such as N-methyl-2-pyrrolidone treatment and introduction of sputtered ZnO and e-beam-evaporated Hf seed layers on monolayer graphene, and the subsequent HfO2 film formation under identical ALD process parameters were systematically evaluated. The nucleation layer provided by the Hf seed layer (which transforms to the HfO2 layer during ALD) resulted in the uniform and conformal deposition of the HfO2 film without damaging the graphene, which is suitable for downscaling the CET. After verifying the feasibility of scaling down the HfO2 thickness to achieve a CET of ~1.5 nm from an array of top-gated metal-oxide-graphene field-effect transistors, we fabricated graphene heterojunction tunnelling transistors with a record-low subthreshold swing value of <60 mV/dec on an 8" glass wafer.

  19. Wafer-scale epitaxial lift-off of optoelectronic grade GaN from a GaN substrate using a sacrificial ZnO interlayer

    Science.gov (United States)

    Rajan, Akhil; Rogers, David J.; Ton-That, Cuong; Zhu, Liangchen; Phillips, Matthew R.; Sundaram, Suresh; Gautier, Simon; Moudakir, Tarik; El-Gmili, Youssef; Ougazzaden, Abdallah; Sandana, Vinod E.; Teherani, Ferechteh H.; Bove, Philippe; Prior, Kevin A.; Djebbour, Zakaria; McClintock, Ryan; Razeghi, Manijeh

    2016-08-01

    Full 2 inch GaN epilayers were lifted off GaN and c-sapphire substrates by preferential chemical dissolution of sacrificial ZnO underlayers. Modification of the standard epitaxial lift-off (ELO) process by supporting the wax host with a glass substrate proved key in enabling full wafer scale-up. Scanning electron microscopy and x-ray diffraction confirmed that intact epitaxial GaN had been transferred to the glass host. Depth-resolved cathodoluminescence (CL) analysis of the bottom surface of the lifted-off GaN layer revealed strong near-band-edge (3.33 eV) emission indicating a superior optical quality for the GaN which was lifted off the GaN substrate. This modified ELO approach demonstrates that previous theories proposing that wax host curling was necessary to keep the ELO etch channel open do not apply to the GaN/ZnO system. The unprecedented full wafer transfer of epitaxial GaN to an alternative support by ELO offers the perspective of accelerating industrial adoption of the expensive GaN substrate through cost-reducing recycling.

  20. Wafer-scaled monolayer WO{sub 3} windows ultra-sensitive, extremely-fast and stable UV-A photodetection

    Energy Technology Data Exchange (ETDEWEB)

    Hai, Zhenyin; Akbari, Mohammad Karbalaei [Ghent University Global Campus, Department of Applied Analytical & Physical Chemistry, Faculty of Bioscience Engineering, 119 Songdomunhwa-ro, Yeonsu-gu, Incheon 21985 (Korea, Republic of); Xue, Chenyang [Key Laboratory of Instrumentation Science and Dynamic Measurement of Ministry of Education, North University of China, Taiyuan, Shanxi 030051 (China); Xu, Hongyan [School of Materials Science and Engineering, North University of China, Taiyuan, Shanxi 030051 (China); Hyde, Lachlan [Melbourne Centre for Nanofabrication, Clayton, Victoria 3168 (Australia); Zhuiykov, Serge, E-mail: serge.zhuiykov@ugent.be [Ghent University Global Campus, Department of Applied Analytical & Physical Chemistry, Faculty of Bioscience Engineering, 119 Songdomunhwa-ro, Yeonsu-gu, Incheon 21985 (Korea, Republic of)

    2017-05-31

    Highlights: • Monolayer WO{sub 3}-based photodetectors were fabricated for the first time. • The device has ultrafast response time of ∼40 μs and responsivity of ∼0.329 A W{sup −1}. • The response time is 400-fold improvement over any other WO{sub 3} UV photodetectors. • The device has better characteristics than many 2D materials-based photodetectors. • This proposed strategy has great potential for commercialization of photodetectors. - Abstract: The monolayer WO{sub 3}-based UV-A photodetectors, fabricated by atomic layer deposition (ALD) technique at the large area of SiO{sub 2}/Si wafer, have demonstrated vastly improved functional capabilities: extremely fast response time of less than 40 μs and photoresponsivity reaching of ∼0.329 A W{sup −1}. Their ultrafast photoresponse time is at least 400-fold improvement over the previous reports for any other WO{sub 3}-based UV photodetectors that have ever been fabricated, and significantly faster than most of other photodetectors based on two-dimensional (2D) nanomaterials reported-to-date. Moreover, their measured long-term stability exceeds more than 200 cycles without any visible degradation. The ALD-deposited WO{sub 3} monolayer has also exhibited wider bandgap of 3.53 eV and the UV-A photodetector based on it is environmentally friendly, highly reliable, with excellent reproducibility and long-term stability. Thus, the shift to mono-layered semiconductors, which possess completely new quantum-confined effects, has the greatest potential in creating a new class of nano-materials, which in return windows new functional opportunities for various opto-electronic instruments built on semiconductor monolayer and, more importantly, can result in new strategy for fabrication highly-flexible, inexpensive and extremely-sensitive devices. This strategy also opens up the great opportunities for industrialization and commercialization of the photodetectors and other optoelectronic devices based on

  1. Experimental Evaluation of Incorporating Digital and Analog Integrated Circuit Die on a Common Substrate Utilizing Silicon-Hybrid Wafer-Scale Integration Technology

    Science.gov (United States)

    1992-03-01

    Program Is Running" ’####### Establish communications with device driver########### OPEN "$DV488" FOR OUTPUT AS #1 ’HP Scope PRINT #1, "BUFFERCLEAR...Packaging Hurdle," Electronics Design 39(8): 99-114. (April 1991). 3. Berry, M. J. Private Communication . Microelectronics Center of North Carolina...INTEGRATION TECNOLOGY 6. AUTHOR(S) Philip C. Reamy, Captain, USAF 7.PEAP07MING 08(3GANILATION ’JAME(S) AND ADDRISS(ES) 8, PERFORMING ORrArN𔃼ATION

  2. Wafer-scale crack-free AlGaN on GaN through two-step selective-area growth for optically pumped stimulated emission

    Science.gov (United States)

    Ko, Young-Ho; Bae, Sung-Bum; Kim, Sung-Bock; Kim, Dong Churl; Leem, Young Ahn; Cho, Yong-Hoon; Nam, Eun-Soo

    2016-07-01

    Crack-free AlGaN template has been successfully grown over entire 2-in. wafer by using 2-step selective-area growth (SAG). The GaN truncated structure was obtained by vertical growth mode with low growth temperature. AlGaN of second step was grown under lateral growth mode. Low pressure enhanced the relative ratio of lateral to vertical growth rate as well as absolute overall growth rate. High V/III ratio was favorable for lateral growth mode. Crack-free planar AlGaN was obtained under low pressure of 30 Torr and high V/III ratio of 4400. The AlGaN was crack-free over entire 2-in. wafer and had quite uniform Al-mole fraction. The dislocation density of the AlGaN with 20% Al-composition was as low as ~7.6×108 /cm2, measured by cathodoluminescence. GaN/AlGaN multi-quantum well (MQW) with cladding and waveguide layers were grown on the crack-free AlGaN template with low dislocation density. It was confirmed that the MQW on the AlGaN template emitted the stimulated emission at 355.5 nm through optical pumping experiment. The AlGaN obtained by 2-step SAG would provide high crystal quality for highly-efficient optoelectronic devices as well as the ultraviolet laser diode.

  3. WDDM - a wafer scale data driven multiprocessor

    Energy Technology Data Exchange (ETDEWEB)

    Shirazi, B.

    1985-01-01

    It has been shown that the existing von-Neumann design machines fail to meet the requirements of the real time scientific and 5th generation applications. A computer organization, such as data driven architecture, which embeds parallelism in its definition and underlying design is needed to satisfy such requirements. In this project, a new data driven multiprocessor is introduced which: (i) eliminates some of the problems of the existing data driven systems; (ii) takes advantage of state of the art technology; and (iii) takes advantage of state-of the art technology; and (iii) achieves parallelism at the data, instruction, and program block levels. This system consists of n processing modules, a host module, and a data structure module, connected via a double star network with the host and the data structure modules in the center of the stars. Processing modules are capable of the simultaneous execution of the independent program blocks in data driven fashion. The host module is responsible for memory management tasks, while the data structure module facilitates the manipulation of the data structures.

  4. Silicon Hybrid Wafer Scale Integration Interconnect Evaluation

    Science.gov (United States)

    1989-12-01

    Since WSI interconnection structures do not always lend themselves to an unam - biguous identification classification within the generalized class of...G.5. Measured chtaracter’ist ic ImpJedlance of St ructutre (G5 fromi Ill’ [)IQ\\ VIh (ceniter conduictor). (a) Niagnit tide. (1)) Ph1ase

  5. Si light-emitting device in integrated photonic CMOS ICs

    Science.gov (United States)

    Xu, Kaikai; Snyman, Lukas W.; Aharoni, Herzl

    2017-07-01

    The motivation for integrated Si optoelectronics is the creation of low-cost photonics for mass-market applications. Especially, the growing demand for sensitive biochemical sensors in the environmental control or medicine leads to the development of integrated high resolution sensors. Here CMOS-compatible Si light-emitting device structures are presented for investigating the effect of various depletion layer profiles and defect engineering on the photonic transition in the 1.4-2.8 eV. A novel Si device is proposed to realize both a two-terminal Si-diode light-emitting device and a three-terminal Si gate-controlled diode light-emitting device in the same device structure. In addition to the spectral analysis, differences between two-terminal and three-terminal devices are discussed, showing the light emission efficiency change. The proposed Si optical source may find potential applications in micro-photonic systems and micro-optoelectro-mechanical systems (MOEMS) in CMOS integrated circuitry.

  6. Batch fabrication of nanopatterned graphene devices via nanoimprint lithography

    DEFF Research Database (Denmark)

    Mackenzie, David; Smistrup, Kristian; Whelan, Patrick Rebsdorf

    2017-01-01

    Previous attempts to tune the electrical properties of large-scale graphene via nanopatterning have led to serious degradation of the key electrical parameters that make graphene a desirable material for electronic devices. We use thermal nanoimprint lithography to pattern wafer-scale graphene...... on a 4-in. wafer with prefabricated 25mm2 devices. The nanopatterning process introduces a modest decrease in carrier mobility and only a minor change in residual doping. Due to the rapid fabrication time of approximately 90 min per wafer, this method has potential for large-scale industrial production....... The chemiresistive gas sensing response towards NO2 was assessed in humid synthetic air and dry air, with devices showing a response to 50 ppb of NO2 only when nanopatterned....

  7. Wafer-scale fabrication of polymer distributed feedback lasers

    DEFF Research Database (Denmark)

    Christiansen, Mads Brøkner; Schøler, Mikkel; Balslev, Søren

    2006-01-01

    techniques, a thin film of polymer, doped with rhodamine-6G laser dye, is spin coated onto a Borofloat glass buffer substrate and shaped into a planar waveguide slab with first order DFB surface corrugations forming the laser resonator. When optically pumped at 532 nm, lasing is obtained in the wavelength...

  8. Direct transfer of wafer-scale graphene films

    Science.gov (United States)

    Kim, Maria; Shah, Ali; Li, Changfeng; Mustonen, Petri; Susoma, Jannatul; Manoocheri, Farshid; Riikonen, Juha; Lipsanen, Harri

    2017-09-01

    Flexible electronics serve as the ubiquitous platform for the next-generation life science, environmental monitoring, display, and energy conversion applications. Outstanding multi-functional mechanical, thermal, electrical, and chemical properties of graphene combined with transparency and flexibility solidifies it as ideal for these applications. Although chemical vapor deposition (CVD) enables cost-effective fabrication of high-quality large-area graphene films, one critical bottleneck is an efficient and reproducible transfer of graphene to flexible substrates. We explore and describe a direct transfer method of 6-inch monolayer CVD graphene onto transparent and flexible substrate based on direct vapor phase deposition of conformal parylene on as-grown graphene/copper (Cu) film. The method is straightforward, scalable, cost-effective and reproducible. The transferred film showed high uniformity, lack of mechanical defects and sheet resistance for doped graphene as low as 18 Ω/sq and 96.5% transparency at 550 nm while withstanding high strain. To underline that the introduced technique is capable of delivering graphene films for next-generation flexible applications we demonstrate a wearable capacitive controller, a heater, and a self-powered triboelectric sensor.

  9. Wafer-Scale Aluminum Nanoplasmonic Resonators with Optimized Metal Deposition

    Science.gov (United States)

    2016-01-04

    Tittl, A.; Michel , A.-K. U.; Schaferling, M.; Yin, X.; Gholipour, B.; Cui, L.; Wuttig, M.; Taubner, T.; Neubrech, F.; Giessen, H. A Switchable Mid...surface plasmon resonances in aluminum nanodisks. Nano Letters 2008, 8, 1461-1471. 41. Chu, Y.; Crozier , K. B. Experimental study of the interaction

  10. Wafer-scale characterization of carrier dynamics in graphene

    DEFF Research Database (Denmark)

    Buron, Jonas Christian Due; Petersen, Dirch Hjorth; Bøggild, Peter

    2015-01-01

    The electronic properties of single-layer graphene, such as surface conductance, carrier concentration, scattering time and mobility, can be characterized in a noncontact manner by THz time-domain spectroscopy. Standard spectroscopic imaging reveals the AC conductance over large areas with a few...... hundred μm resolution, and spectroscopic imaging on back-gated graphene allows for extraction of both the carrier concentration and the mobility. We find that spatial variations of the conductance of single-layer CVD-grown graphene are predominantly due to variations in mobility rather than in carrier...

  11. Application of Optical Forces in Microphotonic Systems

    Science.gov (United States)

    2013-05-01

    light enhancement of radiation pressure in an omnidirectional-reflector waveguide," Applied Physics Letters 85, 1466-1468 (2004). [71]. A. Mizrahi , and...optical waveguides," Opt. Lett. 30, 3042- 3044 (2005). 59 42 [3]. A. Mizrahi , and L. Schachter, "Mirror manipulation by attractive and...Optical and Plasma Physics 46, 157-164 (2008). [10]. A. Mizrahi , and L. Schachter, "Electromagnetic forces on the dielectric layers of the planar

  12. Microfabricated structures and devices featuring nanostructured titania thin films

    Science.gov (United States)

    Monkowski, Adam J.

    2007-05-01

    When titanium reacts with hydrogen peroxide at 80°C--100°C, a nanostructured titania (NST) thin film is formed on the titanium surface. This nanostructured film is particularly suited for integration with thin film and bulk microfabrication techniques. The ability to manufacture devices in a batch format is a principal advantage of microfabrication-based production. To reliably produce arrays of micro-patterned NST thin films on the wafer scale, a patterning guideline must be considered. The formation of NST relies on a re-deposition process; adequate ti-peroxo species must be generated and remain at the solid-solution interface. Numerical analysis of the characteristic transient diffusion behavior for various micro-patterns has been compared with experimental data to generate a criterion to guide the design of NST micro-patterns. Wafer scale arrays of NST micro gas-sensors have been fabricated using standard thin film techniques. Sensing elements are 20 mum on a side. High sensitivity to hydrogen is achieved by modification of the sensors with platinum nanoparticles. When exposed to a 10 mT partial pressure of hydrogen at 250°C, the functionalized devices exhibit more than one order of magnitude resistance decrease with a response time of approximately 7 sec. Titanium microstructures formed using the titanium ICP deep etch (TIDE) process have been integrated with NST films to produce an ordered nanostructure-microstructure composite (3D-NST). The process developed allows for the incorporation of a planar top surface, advantageous for bonding and sealing applications, in which the nanostructured thin film is formed only on feature sidewalls and floors. When titanium microstructures are spaced less than 1 mum apart, titania nanostructures bridge adjacent features. NST and 3D-NST structures have been assembled and tested in a dye-sensitized solar cell (DSSC) device. The NST film is approximately 900nm thick; this yielded a DSSC with an efficiency of 1.8%, similar

  13. Tunable infrared plasmonic devices using graphene/insulator stacks.

    Science.gov (United States)

    Yan, Hugen; Li, Xuesong; Chandra, Bhupesh; Tulevski, George; Wu, Yanqing; Freitag, Marcus; Zhu, Wenjuan; Avouris, Phaedon; Xia, Fengnian

    2012-04-22

    The collective oscillation of carriers--the plasmon--in graphene has many desirable properties, including tunability and low loss. However, in single-layer graphene, the dependence on carrier concentration of both the plasmonic resonance frequency and magnitude is relatively weak, limiting its applications in photonics. Here, we demonstrate transparent photonic devices based on graphene/insulator stacks, which are formed by depositing alternating wafer-scale graphene sheets and thin insulating layers, then patterning them together into photonic-crystal-like structures. We show experimentally that the plasmon in such stacks is unambiguously non-classical. Compared with doping in single-layer graphene, distributing carriers into multiple graphene layers effectively enhances the plasmonic resonance frequency and magnitude, which is different from the effect in a conventional semiconductor superlattice and is a direct consequence of the unique carrier density scaling law of the plasmonic resonance of Dirac fermions. Using patterned graphene/insulator stacks, we demonstrate widely tunable far-infrared notch filters with 8.2 dB rejection ratios and terahertz linear polarizers with 9.5 dB extinction ratios. An unpatterned stack consisting of five graphene layers shields 97.5% of electromagnetic radiation at frequencies below 1.2 THz. This work could lead to the development of transparent mid- and far-infrared photonic devices such as detectors, modulators and three-dimensional metamaterial systems.

  14. Insertion devices

    CERN Document Server

    Bahrdt, J

    2006-01-01

    The interaction of an insertion device with the electron beam in a storage ring is discussed. The radiation property including brightness, ux and polarization of an ideal and real planar and helical / elliptical device is described. The magnet design of planar, helical, quasiperiodic devices and of devices with a reduced on axis power density are resumed.

  15. Photovoltaic device

    Science.gov (United States)

    Reese, Jason A.; Keenihan, James R.; Gaston, Ryan S.; Kauffmann, Keith L.; Langmaid, Joseph A.; Lopez, Leonardo C.; Maak, Kevin D.; Mills, Michael E.; Ramesh, Narayan; Teli, Samar R.

    2015-09-01

    The present invention is premised upon an improved photovoltaic device ("PV device"), more particularly to an improved photovoltaic device (10) with a multilayered photovoltaic cell assembly (100) and a body portion (200) joined at an interface region (410) and including an intermediate layer (500), at least one interconnecting structural member (1500), relieving feature (2500), unique component geometry, or any combination thereof.

  16. Photovoltaic device

    Energy Technology Data Exchange (ETDEWEB)

    Reese, Jason A; Keenihan, James R; Gaston, Ryan S; Kauffmann, Keith L; Langmaid, Joseph A; Lopez, Leonardo; Maak, Kevin D; Mills, Michael E; Ramesh, Narayan; Teli, Samar R

    2017-03-21

    The present invention is premised upon an improved photovoltaic device ("PV device"), more particularly to an improved photovoltaic device with a multilayered photovoltaic cell assembly and a body portion joined at an interface region and including an intermediate layer, at least one interconnecting structural member, relieving feature, unique component geometry, or any combination thereof.

  17. Concentration device

    DEFF Research Database (Denmark)

    2013-01-01

    A concentration device (2) for filter filtration concentration of particles (4) from a volume of a fluid (6). The concentration device (2) comprises a filter (8) configured to filter particles (4) of a predefined size in the volume of the fluid (6). The concentration device (2) comprises...

  18. 12-inch-wafer-scale CMOS active-pixel sensor for digital mammography

    Science.gov (United States)

    Heo, Sung Kyn; Kosonen, Jari; Hwang, Sung Ha; Kim, Tae Woo; Yun, Seungman; Kim, Ho Kyung

    2011-03-01

    This paper describes the development of an active-pixel sensor (APS) panel, which has a field-of-view of 23.1×17.1 cm and features 70-μm-sized pixels arranged in a 3300×2442 array format, for digital mammographic applications. The APS panel was realized on 12-inch wafers based on the standard complementary metal-oxide-semiconductor (CMOS) technology without physical tiling processes of several small-area sensor arrays. Electrical performance of the developed panel is described in terms of dark current, full-well capacity and leakage current map. For mammographic imaging, the optimized CsI:Tl scintillator is experimentally determined by being combined with the developed panel and analyzing im aging characteristics, such as modulation-transfer function, noise-power spectrum, detective quantum efficiency, image l ag, and contrast-detail analysis by using the CDMAM 3.4 phantom. With these results, we suggest that the developed CMOS-based detector can be used for conventional and advanced digital mammographic applications.

  19. Methods for top-down fabrication of wafer scale TMDC monolayers

    Energy Technology Data Exchange (ETDEWEB)

    Das, Saptarshi; Bera, Mrinal K.; Roelofs, Andreas K; Antonio, Mark

    2017-11-07

    A method of forming a TMDC monolayer comprises providing a multi-layer transition metal dichalcogenide (TMDC) film. The multi-layer TMDC film comprises a plurality of layers of the TMDC. The multi-layer TMDC film is positioned on a conducting substrate. The conducting substrate is contacted with an electrolyte solution. A predetermined electrode potential is applied on the conducting substrate and the TMDC monolayer for a predetermined time. A portion of the plurality of layers of the TMDC included in the multi-layer TMDC film is removed by application of the predetermined electrode potential, thereby leaving a TMDC monolayer film positioned on the conducting substrate.

  20. Wafer scale millimeter-wave integrated circuits based on epitaxial graphene in high data rate communication.

    Science.gov (United States)

    Habibpour, Omid; He, Zhongxia Simon; Strupinski, Wlodek; Rorsman, Niklas; Zirath, Herbert

    2017-02-01

    In recent years, the demand for high data rate wireless communications has increased dramatically, which requires larger bandwidth to sustain multi-user accessibility and quality of services. This can be achieved at millimeter wave frequencies. Graphene is a promising material for the development of millimeter-wave electronics because of its outstanding electron transport properties. Up to now, due to the lack of high quality material and process technology, the operating frequency of demonstrated circuits has been far below the potential of graphene. Here, we present monolithic integrated circuits based on epitaxial graphene operating at unprecedented high frequencies (80-100 GHz). The demonstrated circuits are capable of encoding/decoding of multi-gigabit-per-second information into/from the amplitude or phase of the carrier signal. The developed fabrication process is scalable to large wafer sizes.

  1. Wafer-Scale Nanopillars Derived from Block Copolymer Lithography for Surface-Enhanced Raman Spectroscopy

    DEFF Research Database (Denmark)

    Li, Tao; Wu, Kaiyu; Rindzevicius, Tomas

    2016-01-01

    We report a novel nanofabrication process via block copolymer lithography using solvent vapor annealing. The nanolithography process is facile and scalable, enabling fabrication of highly ordered periodic patterns over entire wafers as substrates for surface-enhanced Raman spectroscopy (SERS). Di...

  2. A Wafer scale active pixel CMOS image sensor for generic x-ray radiology

    Science.gov (United States)

    Scheffer, Danny

    2007-03-01

    This paper describes a CMOS Active Pixel Image Sensor developed for generic X-ray imaging systems using standard CMOS technology and an active pixel architecture featuring low noise and a high sensitivity. The image sensor has been manufactured in a standard 0.35 μm technology using 8" wafers. The resolution of the sensor is 3360x3348 pixels of 40x40 μm2 each. The diagonal of the sensor measures little over 190 mm. The paper discusses the floor planning, stitching diagram, and the electro-optical performance of the sensor that has been developed.

  3. Corrugation Architecture Enabled Ultraflexible Wafer-Scale High-Efficiency Monocrystalline Silicon Solar Cell

    KAUST Repository

    Bahabry, Rabab R.

    2018-01-02

    Advanced classes of modern application require new generation of versatile solar cells showcasing extreme mechanical resilience, large-scale, low cost, and excellent power conversion efficiency. Conventional crystalline silicon-based solar cells offer one of the most highly efficient power sources, but a key challenge remains to attain mechanical resilience while preserving electrical performance. A complementary metal oxide semiconductor-based integration strategy where corrugation architecture enables ultraflexible and low-cost solar cell modules from bulk monocrystalline large-scale (127 × 127 cm) silicon solar wafers with a 17% power conversion efficiency. This periodic corrugated array benefits from an interchangeable solar cell segmentation scheme which preserves the active silicon thickness of 240 μm and achieves flexibility via interdigitated back contacts. These cells can reversibly withstand high mechanical stress and can be deformed to zigzag and bifacial modules. These corrugation silicon-based solar cells offer ultraflexibility with high stability over 1000 bending cycles including convex and concave bending to broaden the application spectrum. Finally, the smallest bending radius of curvature lower than 140 μm of the back contacts is shown that carries the solar cells segments.

  4. Wafer scale millimeter-wave integrated circuits based on epitaxial graphene in high data rate communication

    Science.gov (United States)

    Habibpour, Omid; He, Zhongxia Simon; Strupinski, Wlodek; Rorsman, Niklas; Zirath, Herbert

    2017-02-01

    In recent years, the demand for high data rate wireless communications has increased dramatically, which requires larger bandwidth to sustain multi-user accessibility and quality of services. This can be achieved at millimeter wave frequencies. Graphene is a promising material for the development of millimeter-wave electronics because of its outstanding electron transport properties. Up to now, due to the lack of high quality material and process technology, the operating frequency of demonstrated circuits has been far below the potential of graphene. Here, we present monolithic integrated circuits based on epitaxial graphene operating at unprecedented high frequencies (80-100 GHz). The demonstrated circuits are capable of encoding/decoding of multi-gigabit-per-second information into/from the amplitude or phase of the carrier signal. The developed fabrication process is scalable to large wafer sizes.

  5. A Batch Wafer Scale LIGA Assembly and Packaging Technique vai Diffusion Bonding

    Energy Technology Data Exchange (ETDEWEB)

    Christenson, T.R.; Schmale, D.T.

    1999-01-27

    A technique using diffusion bonding (or solid-state welding) has been used to achieve batch fabrication of two- level nickel LIGA structures. Interlayer alignment accuracy of less than 1 micron is achieved using press-fit gauge pins. A mini-scale torsion tester was built to measure the diffusion bond strength of LIGA formed specimens that has shown successful bonding at temperatures of 450"C at 7 ksi pressure with bond strength greater than 100 Mpa. Extensions to this basic process to allow for additional layers and thereby more complex assemblies as well as commensurate packaging are discussed.

  6. FDTD simulation of amorphous silicon waveguides for microphotonics applications

    Science.gov (United States)

    Fantoni, A.; Lourenço, P.; Pinho, P.; Vieira, M.,

    2017-05-01

    In this work we correlate the dimension of the waveguide with small variations of the refractive index of the material used for the waveguide core. We calculate the effective modal refractive index for different dimensions of the waveguide and with slightly variation of the refractive index of the core material. These results are used as an input for a set of Finite Difference Time Domain simulation, directed to study the characteristics of amorphous silicon waveguides embedded in a SiO2 cladding. The study considers simple linear waveguides with rectangular section for studying the modal attenuation expected at different wavelengths. Transmission efficiency is determined analyzing the decay of the light power along the waveguides. As far as near infrared wavelengths are considered, a-Si:H shows a behavior highly dependent on the light wavelength and its extinction coefficient rapidly increases as operating frequency goes into visible spectrum range. The simulation results show that amorphous silicon can be considered a good candidate for waveguide material core whenever the waveguide length is as short as a few centimeters. The maximum transmission length is highly affected by the a-Si:H defect density, the mid-gap density of states and by the waveguide section area. The simulation results address a minimum requirement of 300nm×400nm waveguide section in order to keep attenuation below 1 dB cm-1.

  7. High resolution microphotonic needle for endoscopic imaging (Conference Presentation)

    Science.gov (United States)

    Tadayon, Mohammad Amin; Mohanty, Aseema; Roberts, Samantha P.; Barbosa, Felippe; Lipson, Michal

    2017-02-01

    GRIN (Graded index) lens have revolutionized micro endoscopy enabling deep tissue imaging with high resolution. The challenges of traditional GRIN lenses are their large size (when compared with the field of view) and their limited resolution. This is because of the relatively weak NA in standard graded index lenses. Here we introduce a novel micro-needle platform for endoscopy with much higher resolution than traditional GRIN lenses and a FOV that corresponds to the whole cross section of the needle. The platform is based on polymeric (SU-8) waveguide integrated with a microlens micro fabricated on a silicon substrate using a unique molding process. Due to the high index of refraction of the material the NA of the needle is much higher than traditional GRIN lenses. We tested the probe in a fluorescent dye solution (19.6 µM Alexa Flour 647 solution) and measured a numerical aperture of 0.25, focal length of about 175 µm and minimal spot size of about 1.6 µm. We show that the platform can image a sample with the field of view corresponding to the cross sectional area of the waveguide (80x100 µm2). The waveguide size can in principle be modified to vary size of the imaging field of view. This demonstration, combined with our previous work demonstrating our ability to implant the high NA needle in a live animal, shows that the proposed system can be used for deep tissue imaging with very high resolution and high field of view.

  8. Controlled spontaneous emission in erbium-doped microphotonic materials

    NARCIS (Netherlands)

    Kalkman, Jeroen

    2005-01-01

    Erbium is a rare-earth metal that, when incorporated in a solid, can emit light at a wavelength of 1.5 μm. It plays a key role in current day telecommunication technology as the principle ingredient of optical fiber amplifiers. In this thesis the control of the Er spontaneous emission in three

  9. Ferroelectric devices

    CERN Document Server

    Uchino, Kenji

    2009-01-01

    Updating its bestselling predecessor, Ferroelectric Devices, Second Edition assesses the last decade of developments-and setbacks-in the commercialization of ferroelectricity. Field pioneer and esteemed author Uchino provides insight into why this relatively nascent and interdisciplinary process has failed so far without a systematic accumulation of fundamental knowledge regarding materials and device development.Filling the informational void, this collection of information reviews state-of-the-art research and development trends reflecting nano and optical technologies, environmental regulat

  10. Catalytic devices

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Ming; Zhang, Xiang

    2018-01-23

    This disclosure provides systems, methods, and apparatus related to catalytic devices. In one aspect, a device includes a substrate, an electrically insulating layer disposed on the substrate, a layer of material disposed on the electrically insulating layer, and a catalyst disposed on the layer of material. The substrate comprises an electrically conductive material. The substrate and the layer of material are electrically coupled to one another and configured to have a voltage applied across them.

  11. Progress of Large-Scale Synthesis and Electronic Device Application of Two-Dimensional Transition Metal Dichalcogenides.

    Science.gov (United States)

    Song, Xiongfei; Guo, Zhongxun; Zhang, Qiaochu; Zhou, Peng; Bao, Wenzhong; Zhang, David Wei

    2017-09-01

    The recent exploration of semiconducting two-dimensional (2D) transition metal dichalcogenides (TMDs) with atomic thickness has taken both the scientific and technological communities by storm. Extensively investigated TMD that are accessible by large-scale synthetic methods materials are remarkably stable, such as MoS2 and WSe2 . They allow superior gate control due to their 2D nature and favorable electronic transport properties, thus suggesting a bright future for digital and RF electronics. In this review, the latest developments in the controlled synthesis of large scale TMDs are firstly introduced by discussing various approaches. The major obstacles that must be overcome to achieve wafer-scale, uniform, and high-quality TMD films for practical electronic applications are included. Advances in the electronic transport studies of TMDs are presented, such as doping, contact engineering, and mobility improvement, which contribute to overall device performance. A perspective and a look at the future for this field is provided in closing. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  12. Identification device

    Science.gov (United States)

    Lin, Jian-Shian; Su, Chih-Chieh; Chou, Ta-Hsin; Wu, Mount-Learn; Lai, Chieh-Lung; Hsu, Che-Lung; Lan, Hsiao-Chin; Huang, Hung-I.; Liu, Yung-Chih; Tu, Zong-Ru; Lee, Chien-Chieh; Chang, Jenq-Yang

    2007-09-01

    In this Letter, the identification device disclosed in the present invention is comprised of: a carrier and a plurality of pseudo-pixels; wherein each of the plural pseudo-pixels is formed on the carrier and is further comprised of at least a light grating composed of a plurality of light grids. In a preferred aspect, each of the plural light grids is formed on the carrier while spacing from each other by an interval ranged between 50nm and 900nm. As the aforesaid identification device can present specific colors and patterns while it is being viewed by naked eye with respect to a specific viewing angle, the identification device is preferred for security and anti-counterfeit applications since the specific colors and patterns will become invisible when it is viewed while deviating from the specific viewing angle.

  13. Robust, low-noise, polarization-maintaining mode-locked Er-fiber laser with a planar lightwave circuit (PLC) device as a multi-functional element.

    Science.gov (United States)

    Kim, Chur; Kwon, Dohyeon; Kim, Dohyun; Choi, Sun Young; Cha, Sang Jun; Choi, Ki Sun; Yeom, Dong-Il; Rotermund, Fabian; Kim, Jungwon

    2017-04-15

    We demonstrate a new planar lightwave circuit (PLC)-based device, integrated with a 980/1550 wavelength division multiplexer, an evanescent-field-interaction-based saturable absorber, and an output tap coupler, which can be employed as a multi-functional element in mode-locked fiber lasers. Using this multi-functional PLC device, we demonstrate a simple, robust, low-noise, and polarization-maintaining mode-locked Er-fiber laser. The measured full-width at half-maximum bandwidth is 6 nm centered at 1555 nm, corresponding to 217 fs transform-limited pulse duration. The measured RIN and timing jitter are 0.22% [10 Hz-10 MHz] and 6.6 fs [10 kHz-1 MHz], respectively. Our results show that the non-gain section of mode-locked fiber lasers can be easily implemented as a single PLC chip that can be manufactured by a wafer-scale fabrication process. The use of PLC processes in mode-locked lasers has the potential for higher manufacturability of low-cost and robust fiber and waveguide lasers.

  14. InP on SOI devices for optical communication and optical network on chip

    Science.gov (United States)

    Fedeli, J.-M.; Ben Bakir, B.; Olivier, N.; Grosse, Ph.; Grenouillet, L.; Augendre, E.; Phillippe, P.; Gilbert, K.; Bordel, D.; Harduin, J.

    2011-01-01

    For about ten years, we have been developing InP on Si devices under different projects focusing first on μlasers then on semicompact lasers. For aiming the integration on a CMOS circuit and for thermal issue, we relied on SiO2 direct bonding of InP unpatterned materials. After the chemical removal of the InP substrate, the heterostructures lie on top of silicon waveguides of an SOI wafer with a separation of about 100nm. Different lasers or photodetectors have been achieved for off-chip optical communication and for intra-chip optical communication within an optical network. For high performance computing with high speed communication between cores, we developed InP microdisk lasers that are coupled to silicon waveguide and produced 100μW of optical power and that can be directly modulated up to 5G at different wavelengths. The optical network is based on wavelength selective circuits with ring resonators. InGaAs photodetectors are evanescently coupled to the silicon waveguide with an efficiency of 0.8A/W. The fabrication has been demonstrated at 200mm wafer scale in a microelectronics clean room for CMOS compatibility. For off-chip communication, silicon on InP evanescent laser have been realized with an innovative design where the cavity is defined in silicon and the gain localized in the QW of bonded InP hererostructure. The investigated devices operate at continuous wave regime with room temperature threshold current below 100 mA, the side mode suppression ratio is as high as 20dB, and the fibercoupled output power is {7mW. Direct modulation can be achieved with already 6G operation.

  15. Detection device

    Science.gov (United States)

    Smith, J.E.

    1981-02-27

    The present invention is directed to a detection device comprising: (1) an entrance chamber; (2) a central chamber; and (3) an exit chamber. The central chamber includes an ionizing gas, anode, and means for connecting the anode with an external power supply and pulse counter.

  16. Medical Devices

    NARCIS (Netherlands)

    Verkerke, Gijsbertus Jacob; Mahieu, H.F.; Geertsema, A.A.; Hermann, I.F.; van Horn, J.R.; Hummel, J. Marjan; van Loon, J.P.; Mihaylov, D.; van der Plaats, A.; Schraffordt Koops, H.; Schutte, H.K.; Veth, R.P.H.; de Vries, M.P.; Rakhorst, G.; Shi, Donglu

    2004-01-01

    The development of new medical devices is a very time-consuming and costly process. Besides the time between the initial idea and the time that manufacturing and testing of prototypes takes place, the time needed for the development of production facilities, production of test series, marketing,

  17. Printing Device

    NARCIS (Netherlands)

    Berg, van den M.J.; Markies, P.R.; Zuilhof, H.

    2014-01-01

    An ink jetprinting device includes a pressure chamber formed by a plurality of wall segments, a first aperture extending through a wall segment and communicating with an ink jet orifice and a second aperture extending through a wall segment and communicating with an ink supply duct. The pressure

  18. Laser device

    Science.gov (United States)

    Scott, Jill R.; Tremblay, Paul L.

    2008-08-19

    A laser device includes a virtual source configured to aim laser energy that originates from a true source. The virtual source has a vertical rotational axis during vertical motion of the virtual source and the vertical axis passes through an exit point from which the laser energy emanates independent of virtual source position. The emanating laser energy is collinear with an orientation line. The laser device includes a virtual source manipulation mechanism that positions the virtual source. The manipulation mechanism has a center of lateral pivot approximately coincident with a lateral index and a center of vertical pivot approximately coincident with a vertical index. The vertical index and lateral index intersect at an index origin. The virtual source and manipulation mechanism auto align the orientation line through the index origin during virtual source motion.

  19. "Distinvar" device

    CERN Multimedia

    CERN PhotoLab

    1965-01-01

    The alignment of one of the accelerator magnets being checked by the AR Division survey group. A "distinvar" device, invented by the group, using calibrated invar wires stretched between the fixed survey pillar (on the left) and a fixed point on the magnet. In two days it is thus possible to measure the alignment of the 100 magnets with an accuracy better than 1/10.

  20. Scalable devices

    KAUST Repository

    Krüger, Jens J.

    2014-01-01

    In computer science in general and in particular the field of high performance computing and supercomputing the term scalable plays an important role. It indicates that a piece of hardware, a concept, an algorithm, or an entire system scales with the size of the problem, i.e., it can not only be used in a very specific setting but it\\'s applicable for a wide range of problems. From small scenarios to possibly very large settings. In this spirit, there exist a number of fixed areas of research on scalability. There are works on scalable algorithms, scalable architectures but what are scalable devices? In the context of this chapter, we are interested in a whole range of display devices, ranging from small scale hardware such as tablet computers, pads, smart-phones etc. up to large tiled display walls. What interests us mostly is not so much the hardware setup but mostly the visualization algorithms behind these display systems that scale from your average smart phone up to the largest gigapixel display walls.

  1. Physics of semiconductor devices

    Energy Technology Data Exchange (ETDEWEB)

    Prew, B.A.

    1975-09-01

    The properties of semiconductors which make them important in the electronic devices industry, and how these properties are controlled by doping, are described. The physics and applications of p-n and other junction devices, and of bulk effect devices are discussed. Avalanche devices, optical devices, solar cells, Schottky barriers, MOS devices, heterojunctions, photoconductors, and transferred electron devices are considered.

  2. Practical microwave electron devices

    CERN Document Server

    Meurant, Gerard

    2013-01-01

    Practical Microwave Electron Devices provides an understanding of microwave electron devices and their applications. All areas of microwave electron devices are covered. These include microwave solid-state devices, including popular microwave transistors and both passive and active diodes; quantum electron devices; thermionic devices (including relativistic thermionic devices); and ferrimagnetic electron devices. The design of each of these devices is discussed as well as their applications, including oscillation, amplification, switching, modulation, demodulation, and parametric interactions.

  3. CLOSURE DEVICE

    Science.gov (United States)

    Linzell, S.M.; Dorcy, D.J.

    1958-08-26

    A quick opening type of stuffing box employing two banks of rotatable shoes, each of which has a caraming action that forces a neoprene sealing surface against a pipe or rod where it passes through a wall is presented. A ring having a handle or wrench attached is placed eccentric to and between the two banks of shoes. Head bolts from the shoes fit into slots in this ring, which are so arranged that when the ring is rotated a quarter turn in one direction the shoes are thrust inwardly to cramp the neopnrene about the pipe, malting a tight seal. Moving the ring in the reverse direction moves the shoes outwardly and frees the pipe which then may be readily removed from the stuffing box. This device has particular application as a closure for the end of a coolant tube of a neutronic reactor.

  4. Medical devices: US medical device regulation.

    Science.gov (United States)

    Jarow, Jonathan P; Baxley, John H

    2015-03-01

    Medical devices are regulated by the US Food and Drug Administration (FDA) within the Center for Devices and Radiological Health. Center for Devices and Radiological Health is responsible for protecting and promoting the public health by ensuring the safety, effectiveness, and quality of medical devices, ensuring the safety of radiation-emitting products, fostering innovation, and providing the public with accurate, science-based information about the products we oversee, throughout the total product life cycle. The FDA was granted the authority to regulate the manufacturing and marketing of medical devices in 1976. It does not regulate the practice of medicine. Devices are classified based on complexity and level of risk, and "pre-1976" devices were allowed to remain on the market after being classified without FDA review. Post-1976 devices of lower complexity and risk that are substantially equivalent to a marketed "predicate" device may be cleared through the 510(k) premarket notification process. Clinical data are typically not needed for 510(k) clearance. In contrast, higher-risk devices typically require premarket approval. Premarket approval applications must contain data demonstrating reasonable assurance of safety and efficacy, and this information typically includes clinical data. For novel devices that are not high risk, the de novo process allows FDA to simultaneously review and classify new devices. Devices that are not legally marketed are permitted to be used for clinical investigation purposes in the United States under the Investigational Device Exemptions regulation. Published by Elsevier Inc.

  5. Connector device for building integrated photovoltaic device

    Energy Technology Data Exchange (ETDEWEB)

    Keenihan, James R.; Langmaid, Joe A.; Eurich, Gerald K.; Lesniak, Michael J.; Mazor, Michael H.; Cleerman, Robert J.; Gaston, Ryan S.

    2015-11-10

    The present invention is premised upon a connector device and method that can more easily electrically connect a plurality of PV devices or photovoltaic system components and/or locate these devices/components upon a building structure. It also may optionally provide some additional sub-components (e.g. at least one bypass diode and/or an indicator means) and may enhance the serviceability of the device.

  6. Wafer-Scale Synthesized MoS2/Porous Silicon Nanostructures for Efficient and Selective Ethanol Sensing at Room Temperature.

    Science.gov (United States)

    Dwivedi, Priyanka; Das, Samaresh; Dhanekar, Saakshi

    2017-06-21

    This paper presents the performance of a highly selective ethanol sensor based on MoS2-functionalized porous silicon (PSi). The uniqueness of the sensor includes its method of fabrication, wafer scalability, affinity for ethanol, and high sensitivity. MoS2 nanoflakes (NFs) were synthesized by sulfurization of oxidized radio-frequency (RF)-sputtered Mo thin films. The MoS2 NFs synthesis technique is superior in comparison to other methods, because it is chip-scalable and low in cost. Interdigitated electrodes (IDEs) were used to record resistive measurements from MoS2/PSi sensors in the presence of volatile organic compound (VOC) and moisture at room temperature. With the effect of MoS2 on PSi, an enhancement in sensitivity and a selective response for ethanol were observed, with a minimum detection limit of 1 ppm. The ethanol sensitivity was found to increase by a factor of 5, in comparison to the single-layer counterpart levels. This impressive response is explained on the basis of an analytical resistive model, the band gap of MoS2/PSi/Si, the interface formed between MoS2 and PSi, and the chemical interaction of the vapor molecules and the surface. This two-dimensional (2D) composite material with PSi paves the way for efficient, highly responsive, and stable sensors.

  7. Heterogeneous integration of lithium niobate and silicon nitride waveguides for wafer-scale photonic integrated circuits on silicon.

    Science.gov (United States)

    Chang, Lin; Pfeiffer, Martin H P; Volet, Nicolas; Zervas, Michael; Peters, Jon D; Manganelli, Costanza L; Stanton, Eric J; Li, Yifei; Kippenberg, Tobias J; Bowers, John E

    2017-02-15

    An ideal photonic integrated circuit for nonlinear photonic applications requires high optical nonlinearities and low loss. This work demonstrates a heterogeneous platform by bonding lithium niobate (LN) thin films onto a silicon nitride (Si3N4) waveguide layer on silicon. It not only provides large second- and third-order nonlinear coefficients, but also shows low propagation loss in both the Si3N4 and the LN-Si3N4 waveguides. The tapers enable low-loss-mode transitions between these two waveguides. This platform is essential for various on-chip applications, e.g., modulators, frequency conversions, and quantum communications.

  8. Wafer scale imprint uniformity evaluated by LSPR spectroscopy: a high volume characterization method for nanometer scale structures

    DEFF Research Database (Denmark)

    Jeppesen, Claus; Lindstedt, Daniel Nilsson; Vig, Asger Laurberg

    2012-01-01

    numerical simulations of imprinted structures characterized by atomic force microscopy. There is a fair agreement between the two methods and the simulations enable the translation of optical spectra to critical dimensions of the physical structures, a concept known from scatterometry. The results...

  9. Wafer-scale single-crystal perovskite patterned thin films based on geometrically-confined lateral crystal growth

    Science.gov (United States)

    Lee, Lynn; Baek, Jangmi; Park, Kyung Sun; Lee, Yong-Eunkoo; Shrestha, Nabeen K.; Sung, Myung M.

    2017-07-01

    We report a facile roll-printing method, geometrically confined lateral crystal growth, for the fabrication of large-scale, single-crystal CH3NH3PbI3 perovskite thin films. Geometrically confined lateral crystal growth is based on transfer of a perovskite ink solution via a patterned rolling mould to a heated substrate, where the solution crystallizes instantly with the immediate evaporation of the solvent. The striking feature of this method is that the instant crystallization of the feeding solution under geometrical confinement leads to the unidirectional lateral growth of single-crystal perovskites. Here, we fabricated single-crystal perovskites in the form of a patterned thin film (3 × 3 inch) with a high carrier mobility of 45.64 cm2 V-1 s-1. We also used these single-crystal perovskite thin films to construct solar cells with a lateral configuration. Their active-area power conversion efficiency shows a highest value of 4.83%, which exceeds the literature efficiency values of lateral perovskite solar cells.

  10. Investigation of a Hybrid Wafer Scale Integration Technique that Mounts Discrete Integrated Circuit Die in a Silicon Substrate.

    Science.gov (United States)

    1988-03-01

    preparation of wafers for the etching study: 1. Chemicals for Standard Clean #1: Sulphuric acid (H 2SO4) Hydrogen Peroxide (H20 2 ) Hydrofluoric Acid (HF) 2...between the die and the substrate, applying a conformal dielectric smoothing layer, and then interconnecting the circuit die using a patterned thin...continued processing. A dielectric polvimide coating is spun-on and cured. Multilevel electrical a- interconnect ions are now possible (3:845-851

  11. 11.72 sq cm SiC Wafer-scale Interconnected 64 kA PiN Diode

    Science.gov (United States)

    2012-01-30

    breakdown voltage yield of 83% was achieved. The diodes selected demonstrate sharp onsets of breakdown voltage as illustrated in Fig. 3. Diodes...645-648, pp. 1017-1020, 2010. [2] D. Peters, W. Bartsch , B. Thomas, and R. Sommer, ―6.5 kV SiC PiN Diodes with Improved Forward Characteristics

  12. Semiconductor nanowires directly grown on graphene--towards wafer scale transferable nanowire arrays with improved electrical contact.

    Science.gov (United States)

    Alper, John P; Gutes, Albert; Carraro, Carlo; Maboudian, Roya

    2013-05-21

    We present for the first time the growth of dense arrays of silicon and silicon carbide nanowires directly on graphene as well as methods of transferring these novel hybrids to arbitrary substrates. Improved electrical contact for SiC nanowire/graphene hybrid is demonstrated in the application of a robust supercapacitor electrode.

  13. Wafer-scale single-crystal perovskite patterned thin films based on geometrically-confined lateral crystal growth

    Science.gov (United States)

    Lee, Lynn; Baek, Jangmi; Park, Kyung Sun; Lee, Yong-EunKoo; Shrestha, Nabeen K.; Sung, Myung M.

    2017-01-01

    We report a facile roll-printing method, geometrically confined lateral crystal growth, for the fabrication of large-scale, single-crystal CH3NH3PbI3 perovskite thin films. Geometrically confined lateral crystal growth is based on transfer of a perovskite ink solution via a patterned rolling mould to a heated substrate, where the solution crystallizes instantly with the immediate evaporation of the solvent. The striking feature of this method is that the instant crystallization of the feeding solution under geometrical confinement leads to the unidirectional lateral growth of single-crystal perovskites. Here, we fabricated single-crystal perovskites in the form of a patterned thin film (3 × 3 inch) with a high carrier mobility of 45.64 cm2 V−1 s−1. We also used these single-crystal perovskite thin films to construct solar cells with a lateral configuration. Their active-area power conversion efficiency shows a highest value of 4.83%, which exceeds the literature efficiency values of lateral perovskite solar cells. PMID:28691697

  14. Medical Device Safety

    Science.gov (United States)

    A medical device is any product used to diagnose, cure, or treat a condition, or to prevent disease. They ... may need one in a hospital. To use medical devices safely Know how your device works. Keep ...

  15. Infrared criminalistic devices

    Science.gov (United States)

    Gibin, Igor S.; Savkov, E. V.; Popov, Pavel G.

    1996-12-01

    We are presenting the devices of near-IR spectral range in this report. The devices may be used in criminalistics, in bank business, in restoration works, etc. the action principle of these devices is describing briefly.

  16. Implantable electronic medical devices

    CERN Document Server

    Fitzpatrick, Dennis

    2014-01-01

    Implantable Electronic Medical Devices provides a thorough review of the application of implantable devices, illustrating the techniques currently being used together with overviews of the latest commercially available medical devices. This book provides an overview of the design of medical devices and is a reference on existing medical devices. The book groups devices with similar functionality into distinct chapters, looking at the latest design ideas and techniques in each area, including retinal implants, glucose biosensors, cochlear implants, pacemakers, electrical stimulation t

  17. Ultraefficient Themoelectric Devices Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Thermoelectric (TE) devices already found a wide range of commercial, military and aerospace applications. However, at present commercially available TE devices...

  18. Self-aligned 0-level sealing of MEMS devices by a two layer thin film reflow process

    NARCIS (Netherlands)

    Rusu, C.R.; Jansen, Henricus V.; Gunn, R.; Witvrouw, A.

    2003-01-01

    Many micro electromechanical systems (MEMS) require a vacuum or controlled atmosphere encapsulation in order to ensure either a good performance or an acceptable lifetime of operation. Two approaches for wafer-scale zero-level packaging exist. The most popular approach is based on wafer bonding.

  19. Implantable CMOS Biomedical Devices

    Directory of Open Access Journals (Sweden)

    Toshihiko Noda

    2009-11-01

    Full Text Available The results of recent research on our implantable CMOS biomedical devices are reviewed. Topics include retinal prosthesis devices and deep-brain implantation devices for small animals. Fundamental device structures and characteristics as well as in vivo experiments are presented.

  20. Hip supporting device

    DEFF Research Database (Denmark)

    2011-01-01

    The present invention relates to a device for limiting movements in one or more anatomical joints, such as a device for limiting movement in the human hip joint after hip replacement surgery. This is provided by a device for limiting movement in the human hip joint, said device comprising: at least...

  1. Blood Glucose Monitoring Devices

    Science.gov (United States)

    ... In Vitro Diagnostics Blood Glucose Monitoring Devices Blood Glucose Monitoring Devices Share Tweet Linkedin Pin it More ... care settings to measure the amount of sugar (glucose) in your blood. What is glucose? Glucose is ...

  2. Implantable Medical Devices

    Science.gov (United States)

    ... Artery Disease Venous Thromboembolism Aortic Aneurysm More Implantable Medical Devices Updated:Sep 16,2016 For Rhythm Control ... a Heart Attack Introduction Medications Surgical Procedures Implantable Medical Devices • Life After a Heart Attack • Heart Attack ...

  3. Heterostructures and quantum devices

    CERN Document Server

    Einspruch, Norman G

    1994-01-01

    Heterostructure and quantum-mechanical devices promise significant improvement in the performance of electronic and optoelectronic integrated circuits (ICs). Though these devices are the subject of a vigorous research effort, the current literature is often either highly technical or narrowly focused. This book presents heterostructure and quantum devices to the nonspecialist, especially electrical engineers working with high-performance semiconductor devices. It focuses on a broad base of technical applications using semiconductor physics theory to develop the next generation of electrical en

  4. Photovoltaic device and method

    Science.gov (United States)

    Cleereman, Robert J; Lesniak, Michael J; Keenihan, James R; Langmaid, Joe A; Gaston, Ryan; Eurich, Gerald K; Boven, Michelle L

    2015-01-27

    The present invention is premised upon an improved photovoltaic device ("PVD") and method of use, more particularly to an improved photovoltaic device with an integral locator and electrical terminal mechanism for transferring current to or from the improved photovoltaic device and the use as a system.

  5. Air Stable Photovoltaic Device

    DEFF Research Database (Denmark)

    2010-01-01

    A method of forming a conducting polymer based photovoltaic device comprising the steps of : (a) providing a transparent first electrode; (b) providing the transparent first electrode with a layer of metal oxide nanoparticles, wherein the metal oxide is selected from the group consisting of : TiO2...... polymer based photovoltaic device, and polymeric compounds suitable for use in such devices and methods....

  6. Device-less interaction

    NARCIS (Netherlands)

    Monaci, G.; Triki, M.; Sarroukh, B.E.

    2009-01-01

    This document describes the results of a technology survey for device-less interaction. The Device-less Interaction project (2007-307) aims at providing interaction options for future home appliances without resorting to a remote control or any other dedicated control device. The target home

  7. Photovoltaic device and method

    Energy Technology Data Exchange (ETDEWEB)

    Cleereman, Robert; Lesniak, Michael J.; Keenihan, James R.; Langmaid, Joe A.; Gaston, Ryan; Eurich, Gerald K.; Boven, Michelle L.

    2015-11-24

    The present invention is premised upon an improved photovoltaic device ("PVD") and method of use, more particularly to an improved photovoltaic device with an integral locator and electrical terminal mechanism for transferring current to or from the improved photovoltaic device and the use as a system.

  8. Tribology of medical devices

    Directory of Open Access Journals (Sweden)

    Z.M. Jin

    2016-12-01

    Full Text Available Importance of tribology in a number of medical devices and surgical instruments is reviewed, including artificial joints, artificial teeth, dental implants and orthodontic appliances, cardiovascular devices, contact lenses, artificial limbs and surgical instruments. The current focus and future developments of these medical devices are highlighted from a tribological point of view, together with the underlying mechanisms.

  9. Smart portable rehabilitation devices

    Directory of Open Access Journals (Sweden)

    Leahey Matt

    2005-07-01

    Full Text Available Abstract Background The majority of current portable orthotic devices and rehabilitative braces provide stability, apply precise pressure, or help maintain alignment of the joints with out the capability for real time monitoring of the patient's motions and forces and without the ability for real time adjustments of the applied forces and motions. Improved technology has allowed for advancements where these devices can be designed to apply a form of tension to resist motion of the joint. These devices induce quicker recovery and are more effective at restoring proper biomechanics and improving muscle function. However, their shortcoming is in their inability to be adjusted in real-time, which is the most ideal form of a device for rehabilitation. This introduces a second class of devices beyond passive orthotics. It is comprised of "active" or powered devices, and although more complicated in design, they are definitely the most versatile. An active or powered orthotic, usually employs some type of actuator(s. Methods In this paper we present several new advancements in the area of smart rehabilitation devices that have been developed by the Northeastern University Robotics and Mechatronics Laboratory. They are all compact, wearable and portable devices and boast re-programmable, real time computer controlled functions as the central theme behind their operation. The sensory information and computer control of the three described devices make for highly efficient and versatile systems that represent a whole new breed in wearable rehabilitation devices. Their applications range from active-assistive rehabilitation to resistance exercise and even have applications in gait training. The three devices described are: a transportable continuous passive motion elbow device, a wearable electro-rheological fluid based knee resistance device, and a wearable electrical stimulation and biofeedback knee device. Results Laboratory tests of the devices

  10. FLUIDICS DEVICE FOR ASSAY

    DEFF Research Database (Denmark)

    2007-01-01

    The present invention relates to a device for use in performing assays on standard laboratory solid supports whereon chemical entities are attached. The invention furthermore relates to the use of such a device and a kit comprising such a device. The device according to the present invention...... is adapted to receive one or more replaceable solid support(s) (40) onto which chemical entities (41) are attached, said device comprising a base (1, 60, 80, 300, 400, 10, 70, 140, 20, 90, 120, 150, 30, 100), one or more inlet(s) (5), one or more outlet(s) (6). The base and the solid support (40) defines......, when operatively connected, one or more chambers (21) comprising the chemical entities (41), the inlet(s) (5) and outlet(s) (6) and chambers (21) being in fluid connection. The device further comprise means for providing differing chemical conditions in each chamber (21)....

  11. Establishment Registration & Device Listing

    Data.gov (United States)

    U.S. Department of Health & Human Services — This searchable database contains establishments (engaged in the manufacture, preparation, propagation, compounding, assembly, or processing of medical devices...

  12. Smart devices are different

    DEFF Research Database (Denmark)

    Stisen, Allan; Blunck, Henrik; Bhattacharya, Sourav

    2015-01-01

    research results. This is due to variations in training and test device hardware and their operating system characteristics among others. In this paper, we systematically investigate sensor-, device- and workload-specific heterogeneities using 36 smartphones and smartwatches, consisting of 13 different......The widespread presence of motion sensors on users' personal mobile devices has spawned a growing research interest in human activity recognition (HAR). However, when deployed at a large-scale, e.g., on multiple devices, the performance of a HAR system is often significantly lower than in reported...

  13. Understanding medical device regulation.

    Science.gov (United States)

    Galgon, Richard E

    2016-12-01

    The purpose of this article is to provide a structural and functional understanding of the systems used for the regulation of medical devices in the USA and European Union (EU). Safe and effective anesthesia care depends heavily on medical devices, including simple, low risk devices to complex life-supporting and life-sustaining devices. In the USA and EU, the Food and Drug Administration and European Commission, respectively, provide regulatory oversight to ensure medical devices are reasonably safe and effective when used for their intended purposes. Unfortunately, practicing anesthesiologists generally have little or no understanding of how medical devices are regulated, nor do they have sufficient knowledge of available adverse event reporting systems. The US and EU medical device regulatory systems are similar in many ways, but differ in important ways too, which impacts the afforded level of safety and effectiveness assurance. In both systems, medical devices are classified and regulated on a risk basis, which fundamentally differs from drug regulation, where uniform requirements are imposed. Anesthesia providers must gain knowledge of these systems and be active players in both premarket and postmarket activities, particularly with regard to vigilance and adverse event/device failure reporting.

  14. Virtual Training Devices Laboratory

    Data.gov (United States)

    Federal Laboratory Consortium — The Virtual Training Devices (VTD) Laboratory at the Life Cycle Software Engineering Center, Picatinny Arsenal, provides a software testing and support environment...

  15. Tunable superluminal propagation on a silicon microchip.

    Science.gov (United States)

    Manipatruni, Sasikanth; Dong, Po; Xu, Qianfan; Lipson, Michal

    2008-12-15

    We demonstrate tunable superluminal propagation in a silicon microphotonic device in a solid-state room-temperature device of tens of micrometers in dimension allowing easy integration with high-bandwidth room-temperature systems. We achieve tunable negative delays up to 85 ps and effective group indices tunable between -1158 and -312.

  16. Design, simulation and characterization of silicon compatible light emitting devices for optical interconnects

    Science.gov (United States)

    Redding, Brandon Fairfield

    Silicon photonics is well suited to overcome the interconnect bottleneck currently limiting performance in electronic integrated circuits. Photonic interconnects benefit from higher bandwidth, reduced power consumption, and improved scaling with device size relative to their electronic counterparts. Realization of photonic interconnects on a Si platform would enable monolithic integration of electronic and photonic elements, thereby leveraging the considerable infrastructure developed by the Si electronics industry. Inspired by this goal, researchers in the field of Si microphotonics have demonstrated most of the capabilities required for optical communication, including waveguides, modulators, filters, switches and detectors. The key element missing from the Si photonics toolkit remains a monolithic light source. In this work, we study two of the most promising materials in the search for a Si based light source: silicon nanocrystals (Si-nc) and erbium doped glass (Er:SiO2). We developed fabrication processes for both of these materials and performed extensive material characterization to acquire the parameters governing their respective rate equation models. We then used our model to design a series of light emitting devices. We first designed Si-nc distributed Bragg reflector (DBR) microcavities for enhanced spontaneous emission and lasing. The optimized vertically emitting structure exhibited a quality factor of 115 and a peak luminescence enhancement factor of 14.5. We then fabricated a device based on our modeling and observed an experimental quality factor of 140 and an enhancement factor of 15.2. We also applied our simulation tool to investigate amplification and enhanced spontaneous emission in Er:SiO2 based devices. Due to the low refractive index of Er:SiO2, we presented a horizontal slot geometry in which the Er:SiO2 layer is sandwiched between Si layers. We used a modesolver to optimize this geometry and then integrated it in a ring microcavity to

  17. Rooting an Android Device

    Science.gov (United States)

    2015-09-01

    o 8-GB Memory o Intel Xeon X5472 Central Processing Unit (CPU)  64-bit quad and dual-core  3.0 GHz 3. Rooting Android Devices The rooting...root access has been granted. 4. Conclusion This document serves as a tutorial on how to grant user administrative privilege to an Android device by

  18. Microfabricated particle focusing device

    Energy Technology Data Exchange (ETDEWEB)

    Ravula, Surendra K.; Arrington, Christian L.; Sigman, Jennifer K.; Branch, Darren W.; Brener, Igal; Clem, Paul G.; James, Conrad D.; Hill, Martyn; Boltryk, Rosemary June

    2013-04-23

    A microfabricated particle focusing device comprises an acoustic portion to preconcentrate particles over large spatial dimensions into particle streams and a dielectrophoretic portion for finer particle focusing into single-file columns. The device can be used for high throughput assays for which it is necessary to isolate and investigate small bundles of particles and single particles.

  19. Incore measuring device

    Energy Technology Data Exchange (ETDEWEB)

    Nishimiya, Akira

    1997-01-28

    In an incore measuring device comprising a first function for controlling a state of a neutron flux distribution in a reactor core and a second function for analyzing, displaying and memorizing information of a state such as of a neutron flux distribution, the second function is separated from the main processing device and it is constituted in other processing device, and further a display device is connected to the other processing device. In addition, a tool for performing maintenance of memory device, touch panel, and software is disposed. Then, load on the main processing device can be reduced, high speed control of the neutron distribution state measuring and controlling portion is enabled, and high speed control of the device for displaying information on the recognized and analyzed state is also enabled. Further, it is possible for high speed data memorizing processing, and improvement of safety of indication operation such as for incore measurement and workability of the maintenance of control softwares. (N.H.)

  20. Process control device

    Energy Technology Data Exchange (ETDEWEB)

    Hayashi, Toshifumi; Kobayashi, Hiroshi

    1994-09-09

    A process control device comprises a memory device for memorizing a plant operation target, a plant state or a state of equipments related with each other as control data, a read-only memory device for storing programs, a plant instrumentation control device or other process control devices, an input/output device for performing input/output with an operator, and a processing device which conducts processing in accordance with the program and sends a control demand or a display demand to the input/output device. The program reads out control data relative to a predetermined operation target, compares and verify them with actual values to read out control data to be a practice premise condition which is further to be a practice premise condition if necessary, thereby automatically controlling the plant or requiring or displaying input. Practice presuming conditions for the operation target can be examined succesively in accordance with the program without constituting complicated logical figures and AND/OR graphs. (N.H.).

  1. Compound semiconductor device modelling

    CERN Document Server

    Miles, Robert

    1993-01-01

    Compound semiconductor devices form the foundation of solid-state microwave and optoelectronic technologies used in many modern communication systems. In common with their low frequency counterparts, these devices are often represented using equivalent circuit models, but it is often necessary to resort to physical models in order to gain insight into the detailed operation of compound semiconductor devices. Many of the earliest physical models were indeed developed to understand the 'unusual' phenomena which occur at high frequencies. Such was the case with the Gunn and IMPATI diodes, which led to an increased interest in using numerical simulation methods. Contemporary devices often have feature sizes so small that they no longer operate within the familiar traditional framework, and hot electron or even quantum­ mechanical models are required. The need for accurate and efficient models suitable for computer aided design has increased with the demand for a wider range of integrated devices for operation at...

  2. Metallic spintronic devices

    CERN Document Server

    Wang, Xiaobin

    2014-01-01

    Metallic Spintronic Devices provides a balanced view of the present state of the art of metallic spintronic devices, addressing both mainstream and emerging applications from magnetic tunneling junction sensors and spin torque oscillators to spin torque memory and logic. Featuring contributions from well-known and respected industrial and academic experts, this cutting-edge work not only presents the latest research and developments but also: Describes spintronic applications in current and future magnetic recording devicesDiscusses spin-transfer torque magnetoresistive random-access memory (STT-MRAM) device architectures and modelingExplores prospects of STT-MRAM scaling, such as detailed multilevel cell structure analysisInvestigates spintronic device write and read optimization in light of spintronic memristive effectsConsiders spintronic research directions based on yttrium iron garnet thin films, including spin pumping, magnetic proximity, spin hall, and spin Seebeck effectsProposes unique solutions for ...

  3. Device for cutting protrusions

    Science.gov (United States)

    Bzorgi, Fariborz M [Knoxville, TN

    2011-07-05

    An apparatus for clipping a protrusion of material is provided. The protrusion may, for example, be a bolt head, a nut, a rivet, a weld bead, or a temporary assembly alignment tab protruding from a substrate surface of assembled components. The apparatus typically includes a cleaver having a cleaving edge and a cutting blade having a cutting edge. Generally, a mounting structure configured to confine the cleaver and the cutting blade and permit a range of relative movement between the cleaving edge and the cutting edge is provided. Also typically included is a power device coupled to the cutting blade. The power device is configured to move the cutting edge toward the cleaving edge. In some embodiments the power device is activated by a momentary switch. A retraction device is also generally provided, where the retraction device is configured to move the cutting edge away from the cleaving edge.

  4. Optical thin film devices

    Science.gov (United States)

    Mao, Shuzheng

    1991-11-01

    Thin film devices are applied to almost all modern scientific instruments, and these devices, especially optical thin film devices, play an essential role in the performances of the instruments, therefore, they are attracting more and more attention. Now there are numerous kinds of thin film devices and their applications are very diversified. The 300-page book, 'Thin Film Device and Applications,' by Prof. K. L. Chopra gives some general ideas, and my paper also outlines the designs, fabrication, and applications of some optical thin film devices made in my laboratory. Optical thin film devices have been greatly developed in the recent decades. Prof. A. Thelan has given a number of papers on the theory and techniques, Prof. H. A. Macleod's book, 'Thin Film Optical Filters,' has concisely concluded the important concepts of optical thin film devices, and Prof. J. A. Dobrowobski has proposed many successful designs for optical thin film devices. Recently, fully-automatic plants make it easier to produce thin film devices with various spectrum requirements, and some companies, such as Balzers, Leybold AG, Satis Vacuum AG, etc., have manufactured such kinds of coating plants for research or mass-production, and the successful example is the production of multilayer antireflection coatings with high stability and reproducibility. Therefore, it could be said that the design of optical thin film devices and coating plants is quite mature. However, we cannot expect that every problem has been solved, the R&D work still continues, the competition still continues, and new design concepts, new techniques, and new film materials are continually developed. Meanwhile, the high-price of fully-automatic coating plants makes unpopular, and automatic design of coating stacks is only the technique for optimizing the manual design according to the physical concepts and experience, in addition, not only the optical system, but also working environment should be taken into account when

  5. 77 FR 69488 - Medical Devices; Custom Devices; Request for Comments

    Science.gov (United States)

    2012-11-19

    ... than orthopedic and dental devices where the custom device exemption may be useful. 4. The type of... HUMAN SERVICES Food and Drug Administration Medical Devices; Custom Devices; Request for Comments AGENCY... of developing an implementation strategy and policy for the custom device exemption criteria in the...

  6. Compound semiconductor device physics

    CERN Document Server

    Tiwari, Sandip

    2013-01-01

    This book provides one of the most rigorous treatments of compound semiconductor device physics yet published. A complete understanding of modern devices requires a working knowledge of low-dimensional physics, the use of statistical methods, and the use of one-, two-, and three-dimensional analytical and numerical analysis techniques. With its systematic and detailed**discussion of these topics, this book is ideal for both the researcher and the student. Although the emphasis of this text is on compound semiconductor devices, many of the principles discussed will also be useful to those inter

  7. Electronic devices and circuits

    CERN Document Server

    Pridham, Gordon John

    1972-01-01

    Electronic Devices and Circuits, Volume 3 provides a comprehensive account on electronic devices and circuits and includes introductory network theory and physics. The physics of semiconductor devices is described, along with field effect transistors, small-signal equivalent circuits of bipolar transistors, and integrated circuits. Linear and non-linear circuits as well as logic circuits are also considered. This volume is comprised of 12 chapters and begins with an analysis of the use of Laplace transforms for analysis of filter networks, followed by a discussion on the physical properties of

  8. Fundamentals of semiconductor devices

    CERN Document Server

    Lindmayer, Joseph

    1965-01-01

    Semiconductor properties ; semiconductor junctions or diodes ; transistor fundamentals ; inhomogeneous impurity distributions, drift or graded-base transistors ; high-frequency properties of transistors ; band structure of semiconductors ; high current densities and mechanisms of carrier transport ; transistor transient response and recombination processes ; surfaces, field-effect transistors, and composite junctions ; additional semiconductor characteristics ; additional semiconductor devices and microcircuits ; more metal, insulator, and semiconductor combinations for devices ; four-pole parameters and configuration rotation ; four-poles of combined networks and devices ; equivalent circuits ; the error function and its properties ; Fermi-Dirac statistics ; useful physical constants.

  9. Powering biomedical devices

    CERN Document Server

    Romero, Edwar

    2013-01-01

    From exoskeletons to neural implants, biomedical devices are no less than life-changing. Compact and constant power sources are necessary to keep these devices running efficiently. Edwar Romero's Powering Biomedical Devices reviews the background, current technologies, and possible future developments of these power sources, examining not only the types of biomedical power sources available (macro, mini, MEMS, and nano), but also what they power (such as prostheses, insulin pumps, and muscular and neural stimulators), and how they work (covering batteries, biofluids, kinetic and ther

  10. Nanoelectronic device applications handbook

    CERN Document Server

    Morris, James E

    2013-01-01

    Nanoelectronic Device Applications Handbook gives a comprehensive snapshot of the state of the art in nanodevices for nanoelectronics applications. Combining breadth and depth, the book includes 68 chapters on topics that range from nano-scaled complementary metal-oxide-semiconductor (CMOS) devices through recent developments in nano capacitors and AlGaAs/GaAs devices. The contributors are world-renowned experts from academia and industry from around the globe. The handbook explores current research into potentially disruptive technologies for a post-CMOS world.These include: Nanoscale advance

  11. Physics of photonic devices

    CERN Document Server

    Chuang, Shun Lien

    2009-01-01

    The most up-to-date book available on the physics of photonic devices This new edition of Physics of Photonic Devices incorporates significant advancements in the field of photonics that have occurred since publication of the first edition (Physics of Optoelectronic Devices). New topics covered include a brief history of the invention of semiconductor lasers, the Lorentz dipole method and metal plasmas, matrix optics, surface plasma waveguides, optical ring resonators, integrated electroabsorption modulator-lasers, and solar cells. It also introduces exciting new fields of research such as:

  12. Output hardcopy devices

    CERN Document Server

    Durbeck, Robert

    1988-01-01

    Output Hardcopy Devices provides a technical summary of computer output hardcopy devices such as plotters, computer output printers, and CRT generated hardcopy. Important related technical areas such as papers, ribbons and inks, color techniques, controllers, and character fonts are also covered. Emphasis is on techniques primarily associated with printing, as well as the plotting capabilities of printing devices that can be effectively used for computer graphics in addition to their various printing functions. Comprised of 19 chapters, this volume begins with an introduction to vector and ras

  13. SLUG HANDLING DEVICES

    Science.gov (United States)

    Gentry, J.R.

    1958-09-16

    A device is described for handling fuel elements of a neutronic reactor. The device consists of two concentric telescoped contalners that may fit about the fuel element. A number of ratchet members, equally spaced about the entrance to the containers, are pivoted on the inner container and spring biased to the outer container so thnt they are forced to hear against and hold the fuel element, the weight of which tends to force the ratchets tighter against the fuel element. The ratchets are released from their hold by raising the inner container relative to the outer memeber. This device reduces the radiation hazard to the personnel handling the fuel elements.

  14. Digital communication device

    DEFF Research Database (Denmark)

    2005-01-01

    The invention concerns a digital communication device like a hearing aid or a headset. The hearing aid or headset has a power supply, a signal processing device, means for receiving a wireless signal and a receiver or loudspeaker, which produces an audio signal based on a modulated pulsed signal...... with high frequency shifting rate produced by the signal processing device. Further the receiver has a first and a second connection point for receiving the pulsed modulated signal wherein the sound producing parts of the receiver are at least partially enclosed by a metal box, whereby a third connection...

  15. Digital Convergence – Smart Devices

    Indian Academy of Sciences (India)

    First page Back Continue Last page Overview Graphics. Digital Convergence – Smart Devices. More and more devices become cheap one-chip components. Different devices are joined to form new multi-purpose devices. Devices and applications converge to form digital personal tools. Behind digital convergence is the ...

  16. Semiconductor devices physics and technology

    CERN Document Server

    Sze, Simon

    2012-01-01

    Semiconductor Devices: Physics and Technology, Third Edition is an introduction to the physical principles of modern semiconductor devices and their advanced fabrication technology. It begins with a brief historical review of major devices and key technologies and is then divided into three sections: semiconductor material properties, physics of semiconductor devices and processing technology to fabricate these semiconductor devices.

  17. Devices for hearing loss

    Science.gov (United States)

    ... or a vibration. Assistive Listening Devices Many sounds, mixing together in a room, can make it harder ... bring the sound from your TV, radio, or music player directly to your inner ear. Many listening ...

  18. MDR (Medical Device Reporting)

    Data.gov (United States)

    U.S. Department of Health & Human Services — This database allows you to search the CDRH's database information on medical devices which may have malfunctioned or caused a death or serious injury during the...

  19. External incontinence devices

    Science.gov (United States)

    ... enable JavaScript. External incontinence devices are products (or appliances). These are worn on the outside of the ... us Disclaimers Copyright Privacy Accessibility Quality Guidelines Viewers & Players MedlinePlus Connect for EHRs For Developers U.S. National ...

  20. Single molecule electronic devices.

    Science.gov (United States)

    Song, Hyunwook; Reed, Mark A; Lee, Takhee

    2011-04-12

    Single molecule electronic devices in which individual molecules are utilized as active electronic components constitute a promising approach for the ultimate miniaturization and integration of electronic devices in nanotechnology through the bottom-up strategy. Thus, the ability to understand, control, and exploit charge transport at the level of single molecules has become a long-standing desire of scientists and engineers from different disciplines for various potential device applications. Indeed, a study on charge transport through single molecules attached to metallic electrodes is a very challenging task, but rapid advances have been made in recent years. This review article focuses on experimental aspects of electronic devices made with single molecules, with a primary focus on the characterization and manipulation of charge transport in this regime. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  1. Adhesion testing device

    Science.gov (United States)

    LaPeyronnie, Glenn M. (Inventor); Huff, Charles M. (Inventor)

    2010-01-01

    The present invention provides a testing apparatus and method for testing the adhesion of a coating to a surface. The invention also includes an improved testing button or dolly for use with the testing apparatus and a self aligning button hook or dolly interface on the testing apparatus. According to preferred forms, the apparatus and method of the present invention are simple, portable, battery operated rugged, and inexpensive to manufacture and use, are readily adaptable to a wide variety of uses, and provide effective and accurate testing results. The device includes a linear actuator driven by an electric motor coupled to the actuator through a gearbox and a rotatable shaft. The electronics for the device are contained in the head section of the device. At the contact end of the device, is positioned a self aligning button hook, attached below the load cell located on the actuator shaft.

  2. Geometry and Cloaking Devices

    Science.gov (United States)

    Ochiai, T.; Nacher, J. C.

    2011-09-01

    Recently, the application of geometry and conformal mappings to artificial materials (metamaterials) has attracted the attention in various research communities. These materials, characterized by a unique man-made structure, have unusual optical properties, which materials found in nature do not exhibit. By applying the geometry and conformal mappings theory to metamaterial science, it may be possible to realize so-called "Harry Potter cloaking device". Although such a device is still in the science fiction realm, several works have shown that by using such metamaterials it may be possible to control the direction of the electromagnetic field at will. We could then make an object hidden inside of a cloaking device. Here, we will explain how to design invisibility device using differential geometry and conformal mappings.

  3. Marine Sanitation Devices (MSDs)

    Science.gov (United States)

    Marine sanitation devices treat or retain sewage from vessels, and have performance standards set by the EPA. This page provides information on MSDs, including who must use an MSD, states' roles, types of MSDs and standards.

  4. High temperature measuring device

    Science.gov (United States)

    Tokarz, Richard D.

    1983-01-01

    A temperature measuring device for very high design temperatures (to 2,000.degree. C.). The device comprises a homogenous base structure preferably in the form of a sphere or cylinder. The base structure contains a large number of individual walled cells. The base structure has a decreasing coefficient of elasticity within the temperature range being monitored. A predetermined quantity of inert gas is confined within each cell. The cells are dimensionally stable at the normal working temperature of the device. Increases in gaseous pressure within the cells will permanently deform the cell walls at temperatures within the high temperature range to be measured. Such deformation can be correlated to temperature by calibrating similarly constructed devices under known time and temperature conditions.

  5. TIME TEMPERATURE INTEGRATION DEVICE

    Science.gov (United States)

    JET ENGINES, * THERMOCOUPLES , AGING(PHYSIOLOGY), BONDING, CHROMIUM, ELECTRICAL CONDUCTIVITY, EXHAUST GASES, GOLD, IRON, MANUFACTURING, MEASUREMENT...PALLADIUM, PLATINUM, PREPARATION, ELECTRICAL RESISTANCE, SILVER, THERMAL DIFFUSION, THIN FILM STORAGE DEVICES , TURBOFAN ENGINES.

  6. Ion funnel device

    Energy Technology Data Exchange (ETDEWEB)

    Ibrahim, Yehia M.; Chen, Tsung-Chi; Harrer, Marques B.; Tang, Keqi; Smith, Richard D.

    2017-11-21

    An ion funnel device is disclosed. A first pair of electrodes is positioned in a first direction. A second pair of electrodes is positioned in a second direction. The device includes an RF voltage source and a DC voltage source. A RF voltage with a superimposed DC voltage gradient is applied to the first pair of electrodes, and a DC voltage gradient is applied to the second pair of electrodes.

  7. Nanoplasmonics advanced device applications

    CERN Document Server

    Chon, James W M

    2013-01-01

    Focusing on control and manipulation of plasmons at nanometer dimensions, nanoplasmonics combines the strength of electronics and photonics, and is predicted to replace existing integrated circuits and photonic devices. It is one of the fastest growing fields of science, with applications in telecommunication, consumer electronics, data storage, medical diagnostics, and energy.Nanoplasmonics: Advanced Device Applications provides a scientific and technological background of a particular nanoplasmonic application and outlines the progress and challenges of the application. It reviews the latest

  8. Communications for Wearable Devices

    OpenAIRE

    Tabibu, Shivram

    2017-01-01

    Wearable devices are transforming computing and the human-computer interaction and they are a primary means for motion recognition of reflexive systems. We review basic wearable deployments and their open wireless communications. An algorithm that uses accelerometer data to provide a control and communication signal is described. Challenges in the further deployment of wearable device in the field of body area network and biometric verification are discussed.

  9. Centering device for casings

    Energy Technology Data Exchange (ETDEWEB)

    Abdulzade, A.M.G.; Aliyev, R.K.; Karash, E.B.; Mamedov, T.R.G.; Puzanov, A.N.; Yakobashvili, M.V.

    1982-01-01

    A centering device is proposed for casings consisting of 2 rings connected by spring planks, and bushing with support element. In order to improve operating reliability of the centering device in the twisted well, the support element of the bushing is made in a cross section in the form of an ellipse and on the outer surface has spiral slits. A support element can be made of elastic material.

  10. Radiographic quality control devices.

    Science.gov (United States)

    2000-04-01

    In this study, we evaluate eight radiographic quality control (QC) devices, which noninvasively measure the output from a variety of diagnostic x-ray production systems. When used as part of a quality assurance (QA) program, radiographic QC devices help ensure that x-ray equipment is working within acceptable limits. This in turn helps ensure that high-quality images are achieved with appropriate radiation doses and that resources are used efficiently (for example, by minimizing the number of repeat exposures required). Our testing focused on the physical performance, ease of use, and service and maintenance characteristics that affect the use of these devices for periodic, routine measurements of x-ray system parameters. We found that all the evaluated models satisfactorily measure all the parameters normally needed for a QA program. However, we did identify a number of differences among the models--particularly in the range of exposure levels that can be effectively measured and the ease of use. Three models perform well for a variety of applications and are very easy to use; we rate them Preferred. Three additional models have minor limitations but otherwise perform well; we rate them Acceptable. We recommend against purchasing two models because, although each performs acceptably for most applications, neither model can measure low levels of radiation. This Evaluation covers devices designed to measure the output of x-ray tubes noninvasively. These devices, called radiographic quality control (QC) devices, or QC meters, are typically used by medical physicists, x-ray engineers, biomedical engineers, and suitably trained radiographic technologists to make QC measurements. We focus on the use of these devices as part of an overall quality assurance (QA) program. We have not evaluated their use for other applications, such as acceptance testing. To be included in this study, a device must be able to measure the exposure- and kVp-related characteristics of most x

  11. Semiconductor device physics and simulation

    CERN Document Server

    Yuan, J S

    1998-01-01

    This volume provides thorough coverage of modern semiconductor devices -including hetero- and homo-junction devices-using a two-dimensional simulator (MEDICI) to perform the analysis and generate simulation results Each device is examined in terms of dc, ac, and transient simulator results; relevant device physics; and implications for design and analysis Two hundred forty-four useful figures illustrate the physical mechanisms and characteristics of the devices simulated Comprehensive and carefully organized, Semiconductor Device Physics and Simulation is the ideal bridge from device physics to practical device design

  12. Active Photonic Devices

    Science.gov (United States)

    Della Valle, Giuseppe; Osellame, Roberto

    The chapter is devoted to active photonic devices fabricated by fs-laser writing. After a brief introduction focused on the role played by fs-laser written active devices, Sect. 10.2 briefly reviews the spectroscopical properties of the most interesting active ions so far exploited, namely erbium, ytterbium, neodimium, and bismuth. In Sect. 10.3 the main figures of merit for an active waveguide, namely the internal gain, the insertion loss, the net gain, and the noise figure are introduced and the experimental procedure for accurate gain measurement is also detailed. A thorough review of the active photonic devices demonstrated with the femtosecond laser microfabrication technique is presented in Sects. 10.4, 10.5, and 10.6, where several active waveguides and amplifiers, prototypal lasers, as well as more functionalized laser devices (operating under single longitudinal mode or stable mode-locking regime) are illustrated, respectively. Finally, conclusions and future perspectives of femtosecond-laser micromachining of active photonic devices are provided.

  13. 76 FR 8637 - Medical Devices; Medical Device Data Systems

    Science.gov (United States)

    2011-02-15

    ... permits manufacturers to introduce into commercial distribution generic types of devices without first.... Moreover, a device or system such as a CPOE system that, for instance, can order tests, medications, or... particular device type, whereas a product intended to be used with generic/multiple types of devices be...

  14. Registration of medical devices

    Directory of Open Access Journals (Sweden)

    Bobby George

    2010-01-01

    Full Text Available Globally the medical device (MD market has been growing quite rapidly over the past decade. The regulatory framework for pharmaceuticals and devices differ substantially. The regulatory authorities in different regions of the world recognize different classes of medical devices (MDs, based on their design complexity, their use characteristics, and their potential for harm, if misused. With the vast majority of MDs in developing countries being imported, the respective governments need to put in place policies & regulations to address all elements related to MDs, ranging from its development, manufacturing, registration to post-marketing obligations & disposal so that public can have access to high quality, safe & affordable products for appropriate use. This article highlights current regulations pertaining to registration of MDs in India, in light of those existing in Global Harmonization Task Force (GHTF member countries & Association of Southeast Asian Nations (ASEAN countries.

  15. Silicon Carbide Electronic Devices

    Science.gov (United States)

    Neudeck, P. G.

    2001-01-01

    The status of emerging silicon carbide (SiC) widebandgap semiconductor electronics technology is briefly surveyed. SiC-based electronic devices and circuits are being developed for use in high-temperature, high-power, and/or high-radiation conditions under which conventional semiconductors cannot function. Projected performance benefits of SiC electronics are briefly illustrated for several applications. However, most of these operational benefits of SiC have yet to be realized in actual systems, primarily owing to the fact that the growth techniques of SiC crystals are relatively immature and device fabrication technologies are not yet sufficiently developed to the degree required for widespread, reliable commercial use. Key crystal growth and device fabrication issues that limit the performance and capability of high-temperature and/or high-power SiC electronics are identified. The electrical and material quality differences between emerging SiC and mature silicon electronics technology are highlighted.

  16. Physics of semiconductor devices

    CERN Document Server

    Rudan, Massimo

    2015-01-01

    This book describes the basic physics of semiconductors, including the hierarchy of transport models, and connects the theory with the functioning of actual semiconductor devices.  Details are worked out carefully and derived from the basic physics, while keeping the internal coherence of the concepts and explaining various levels of approximation. Examples are based on silicon due to its industrial importance. Several chapters are included that provide the reader with the quantum-mechanical concepts necessary for understanding the transport properties of crystals. The behavior of crystals incorporating a position-dependent impurity distribution is described, and the different hierarchical transport models for semiconductor devices are derived (from the Boltzmann transport equation to the hydrodynamic and drift-diffusion models). The transport models are then applied to a detailed description of the main semiconductor-device architectures (bipolar, MOS). The final chapters are devoted to the description of s...

  17. Vacuum distillation device

    Energy Technology Data Exchange (ETDEWEB)

    Hamer, J.A.; Burg, C.J. Van Der; Kanbier, D.; Heijden, P. Van Der.

    1990-09-18

    This invention relates to a vacuum distillation device comprising a vacuum distillation column, a furnace provided with a heat exchange tube, and a connecting conduit between the column and the heat exchange tube. Such a device is used to fractionate a hydrocarbon-containing feed sometimes referred to as long residue. An object of this invention is to provide a vacuum distillation device which allows vaporization of a major part of the feed upstream of the column inlet. To this end, the device according to the invention comprises a vacuum distillation device as described above, in which the inner diameter of the heat exchange tube increases along its length to between 2.4 and 3 times the inner diameter of the tube inlet, and in which the inner diameter of the connecting conduit gradually increases along its length to between 2.5 and 5.4 times the inner diameter of the tube outlet. During normal operation of the device of the invention, only less than 50 wt % of the feed is vaporized in the heat exchange tube in the furnace, and more feed is vaporized in the connecting conduit, so that at the outlet end of the conduit the feed comprises about 0.9 kg vapor per kg of feed. The invention provides improved heat transfer in the heat exchange tubes such that fouling is reduced, consequently more heat can be applied per unit of time in the heat exchange tube. This allows either heating of the feed to a higher temperature or increasing the throughput for the same temperature.

  18. Asphaltene based photovoltaic devices

    Science.gov (United States)

    Chianelli, Russell R.; Castillo, Karina; Gupta, Vipin; Qudah, Ali M.; Torres, Brenda; Abujnah, Rajib E.

    2016-03-22

    Photovoltaic devices and methods of making the same, are disclosed herein. The cell comprises a photovoltaic device that comprises a first electrically conductive layer comprising a photo-sensitized electrode; at least one photoelectrochemical layer comprising metal-oxide particles, an electrolyte solution comprising at least one asphaltene fraction, wherein the metal-oxide particles are optionally dispersed in a surfactant; and a second electrically conductive layer comprising a counter-electrode, wherein the second electrically conductive layer comprises one or more conductive elements comprising carbon, graphite, soot, carbon allotropes or any combinations thereof.

  19. Microfluidic Cell Culture Device

    Science.gov (United States)

    Takayama, Shuichi (Inventor); Cabrera, Lourdes Marcella (Inventor); Heo, Yun Seok (Inventor); Smith, Gary Daniel (Inventor)

    2014-01-01

    Microfluidic devices for cell culturing and methods for using the same are disclosed. One device includes a substrate and membrane. The substrate includes a reservoir in fluid communication with a passage. A bio-compatible fluid may be added to the reservoir and passage. The reservoir is configured to receive and retain at least a portion of a cell mass. The membrane acts as a barrier to evaporation of the bio-compatible fluid from the passage. A cover fluid may be added to cover the bio-compatible fluid to prevent evaporation of the bio-compatible fluid.

  20. Electronic devices and circuits

    CERN Document Server

    Pridham, Gordon John

    1968-01-01

    Electronic Devices and Circuits, Volume 1 deals with the design and applications of electronic devices and circuits such as passive components, diodes, triodes and transistors, rectification and power supplies, amplifying circuits, electronic instruments, and oscillators. These topics are supported with introductory network theory and physics. This volume is comprised of nine chapters and begins by explaining the operation of resistive, inductive, and capacitive elements in direct and alternating current circuits. The theory for some of the expressions quoted in later chapters is presented. Th

  1. Contaminate Control Device

    Science.gov (United States)

    Howe, Robert H. (Inventor); Flynn, Kenneth P. (Inventor); Stapleton, Thomas J. (Inventor)

    2014-01-01

    A contaminate control device for filtering contaminates from a gas such as air is provided. The device includes a housing having a first inlet and a first outlet. An axial flow filter is fluidly coupled between the first inlet and the first outlet, the axial flow filter has a second inlet and a second outlet. A second filter disposed about the axial flow filter and is fluidly coupled between the first inlet and the first outlet, the second filter having a third inlet on an inner diameter and a third outlet disposed on an outer diameter. A flow restrictor is fluidly coupled between the second inlet and the first inlet.

  2. INLET STRATIFICATION DEVICE

    DEFF Research Database (Denmark)

    2006-01-01

    formed of a flexible porous material and having an inlet (19) and outlets formed of the pores of the porous material. The stratification device (5) further comprises at least one outer pipe (7) surrounding the inlet pipe (6) in spaced relationship thereto and being at least partially formed of a porous......An inlet stratification device (5) for a circuit circulating a fluid through a tank (1 ) and for providing and maintaining stratification of the fluid in the tank (1 ). The stratification de- vice (5) is arranged vertically in the tank (1) and comprises an inlet pipe (6) being at least partially...

  3. Preventing medical device recalls

    CERN Document Server

    Raheja, Dev

    2014-01-01

    Introduction to Medical Device RequirementsIntroductionThe ChallengesSources of ErrorsUnderstanding the Science of Safety     Overview of FDA Quality System Regulation     Overview of Risk Management Standard ISO 14971     Overview of FDA Device Approval Process     Overview of Regulatory Requirements for Clinical TrialsSummaryReferencesPreventing Recalls during Specification WritingIntroductionConduct Requirements Analysis to Identify Missing RequirementsSpecifications for Safety, Durability, and

  4. ROTATING PLASMA DEVICE

    Science.gov (United States)

    Boyer, K.; Hammel, J.E.; Longmire, C.L.; Nagle, D.E.; Ribe, F.L.; Tuck, J.L.

    1961-10-24

    ABS>A method and device are described for obtaining fusion reactions. The basic concept is that of using crossed electric and magnetic fields to induce a plasma rotation in which the ionized particles follow a circumferential drift orbit on wldch a cyclotron mode of motion is superimposed, the net result being a cycloidal motion about the axis of symmetry. The discharge tube has a radial electric field and a longitudinal magnetic field. Mirror machine geometry is utilized. The device avoids reliance on the pinch effect and its associated instability problems. (AEC)

  5. Materials for electrochemical device safety

    Science.gov (United States)

    Vissers, Daniel R.; Amine, Khalil; Thackeray, Michael M.; Kahaian, Arthur J.; Johnson, Christopher S.

    2015-04-07

    An electrochemical device includes a thermally-triggered intumescent material or a gas-triggered intumescent material. Such devices prevent or minimize short circuits in a device that could lead to thermal run-away. Such devices may include batteries or supercapacitors.

  6. Device configuration-management system

    Energy Technology Data Exchange (ETDEWEB)

    Nowell, D.M.

    1981-01-01

    The Fusion Chamber System, a major component of the Magnetic Fusion Test Facility, contains several hundred devices which report status to the Supervisory Control and Diagnostic System for control and monitoring purposes. To manage the large number of diversity of devices represented, a device configuration management system was required and developed. Key components of this software tool include the MFTF Data Base; a configuration editor; and a tree structure defining the relationships between the subsystem devices. This paper will describe how the configuration system easily accomodates recognizing new devices, restructuring existing devices, and modifying device profile information.

  7. Device for hermetizing wellheads

    Energy Technology Data Exchange (ETDEWEB)

    Rasi-zade, A.T.; Frenkel, B.O.; Samoylov, Yu.A.

    1978-04-27

    In order to increase operational reliability of cables by preventing friction wear, this device is equipped with an additional T-shaped packing element with a threaded main section that is placed conically to facilitate interaction with the exterior of the locking plate.

  8. Color identification testing device

    Science.gov (United States)

    Brawner, E. L.; Martin, R.; Pate, W.

    1970-01-01

    Testing device, which determines ability of a technician to identify color-coded electric wires, is superior to standard color blindness tests. It tests speed of wire selection, detects partial color blindness, allows rapid testing, and may be administered by a color blind person.

  9. A Medical Delivery Device

    DEFF Research Database (Denmark)

    2010-01-01

    The present invention relates to a medical delivery device comprising at least two membrane electrode assembly units each of which comprises three layers: an upper and a lower electrode and a selective ionic conductive membrane provided there-between. At least one of the three layers are shared...

  10. Device Oriented Project Controller

    Energy Technology Data Exchange (ETDEWEB)

    Dalesio, Leo; Kraimer, Martin

    2013-11-20

    This proposal is directed at the issue of developing control systems for very large HEP projects. A de-facto standard in accelerator control is the Experimental Physics and Industrial Control System (EPICS), which has been applied successfully to many physics projects. EPICS is a channel based system that requires that each channel of each device be configured and controlled. In Phase I, the feasibility of a device oriented extension to the distributed channel database was demonstrated by prototyping a device aware version of an EPICS I/O controller that functions with the current version of the channel access communication protocol. Extensions have been made to the grammar to define the database. Only a multi-stage position controller with limit switches was developed in the demonstration, but the grammar should support a full range of functional record types. In phase II, a full set of record types will be developed to support all existing record types, a set of process control functions for closed loop control, and support for experimental beam line control. A tool to configure these records will be developed. A communication protocol will be developed or extensions will be made to Channel Access to support introspection of components of a device. Performance bench marks will be made on both communication protocol and the database. After these records and performance tests are under way, a second of the grammar will be undertaken.

  11. Single Value Devices

    NARCIS (Netherlands)

    Mader, Angelika H.; Dertien, Edwin Christian; Reidsma, Dennis; Camurri, Antonio; Costa, Cristina

    We live in a world of continuous information overflow, but the quality of information and communication is suffering. Single value devices contribute to information and communication quality by focussing on one explicit, relevant piece of information. The information is decoupled from a computer and

  12. Electrical Sensing Devices.

    Science.gov (United States)

    Montana State Univ., Bozeman. Dept. of Agricultural and Industrial Education.

    This unit of instruction on electrical sensing devices is designed especially for use with freshman vocational agriculture students. A unit plan discusses the general aims and goals, lesson titles, student and teacher activities, and references. The unit consists of four lessons. A lesson plan for each lesson provides these components: need;…

  13. Road-Cleaning Device

    Science.gov (United States)

    Roman, Harry T.

    2014-01-01

    Roadways are literally soaked with petrochemical byproducts, oils, gasoline, and other volatile substances that eventually run off into sewers and end up in rivers, waterways, and other undesirable places. Can the roads be cleaned of these wastes, with their proper disposal? Can vehicles, robots, or other devices be designed that could be driven…

  14. Integrated Optical lightguide device

    NARCIS (Netherlands)

    Heideman, Rene; Lambeck, Paul; Veldhuis, G.J.

    2005-01-01

    In an integrated optical lightguide device including a light-transmitting core layer, an inclusion or buffer layer, and an active or cladding layer. The cladding layer is divided into segments. Groups of different segments exhibit different refractive indices, light intensity profiles or different

  15. Integrated Optical lightguide device

    NARCIS (Netherlands)

    Heideman, Rene; Lambeck, Paul; Veldhuis, G.J.

    2000-01-01

    In an integrated optical lightguide device including a light-transmitting core layer, an inclusion or buffer layer, and an active or cladding layer. The cladding layer is divided into segments. Groups of different segments exhibit different refractive indices, light intensity profiles or different

  16. Nano devices and sensors

    CERN Document Server

    Liaw, Shien-Kuei; Chung, Yung-Hui

    2016-01-01

    This volume on semiconductor devices focuses on such topics as nano-imprinting, lithography, nanowire charge-trapping, thermo-stability in nanowires, nano-electrodes, and voltage and materials used for fabricating and improving electrical characteristics of nano-materials.

  17. Mobile Library Filming Device.

    Science.gov (United States)

    Martin, Claud E.

    This report contains details of the study and performance test of the Mobile Filming Library Device which consists of a camera and self contained power source. Because of the cost savings and service improvement characteristics, this technique involving the use of a microfilm intermediate in the preparation of copies of material filed in full size…

  18. Liver Cell Culture Devices

    NARCIS (Netherlands)

    Andria, B.; Bracco, A.; Cirino, G.; Chamuleau, R. A. F. M.

    2010-01-01

    In the last 15 years many different liver cell culture devices, consisting of functional liver cells and artificial materials, have been developed. They have been devised for numerous different applications, such as temporary organ replacement (a bridge to liver transplantation or native liver

  19. Complex Materials and Devices

    Science.gov (United States)

    2013-03-07

    Disruptive Basic Research Areas” – Metamaterials and Plasmonics – Quantum Information Science – Cognitive Neuroscience – Nanoscience and...Sayir, Fuller) Bio-Sensing of Magnetic Fields (Larkin, Bradshaw, Curcic, DeLong 2D Materials & Devices Beyond Graphene (Hwang, Pomrenke, Harrison

  20. Air Stable Photovoltaic Device

    DEFF Research Database (Denmark)

    2010-01-01

    A method of forming a conducting polymer based photovoltaic device comprising the steps of : (a) providing a transparent first electrode; (b) providing the transparent first electrode with a layer of metal oxide nanoparticles, wherein the metal oxide is selected from the group consisting of : TiO...

  1. XY displacement device

    NARCIS (Netherlands)

    Heerens, W.C.; Laham, C.D.; Holman, A.E.

    1997-01-01

    An XY-displacement device (1) with a four-fold symmetry comprises a reference frame (10); an object mount (20) for holding an object (22) to be displaced; an X-manipulator (100) coupled between the reference frame (10) and the object mount (20), which provides a rigid coupling between the object

  2. Innovative solar control devices

    OpenAIRE

    Erhorn, H.; Erhorn-Kluttig, H.

    2010-01-01

    Buildings are the EU's largest energy users, consuming over 40 % of Europe's total primary energy. One way of cutting this consumption is by avoiding or reducing cooling energy through proper solar shading. This paper presents examples of innovative solar control devices and emphasizes their relevance for the energy performance of buildings.

  3. Standardization of splash device

    Science.gov (United States)

    Fernández Raga, María; Peters, Piet

    2017-04-01

    The erosion is a complex process that has been studied extensively by numerous researchers, requiring a prolongued time effort and a large economic investment. To be effective, the measurements of erosion should be precise, controlled and replicable, and to assure efectiveness, measurement devices of erosion should be properly designed, constructed, well calibrated and also they should be operated by a trained person (Stroosnijder, 2005). Because researchers try to improve old devices, the equipment is constantly being redesigned, making the measurements not comparable and furthermore, producing a lack of available standarized device. The lack of standardization of erosion equipment is more obvious in the case of the local splash erosion, where the nature of the process makes very difficult to isolate its effects. In this article we compare the results obtained from five of the most common splash erosion devices (selected from more than 16 different currently types), under the same rain conditions, with the objective of facilitate the standardization of the method that will be more easy to build, minimizing the error. A set of six splash devices were setted in well known positions under simulated rain, to measured the differences, among devices and the accuracy of the data recovered after 10 minutes of rainfall simulation under different intensities (from 60 to 130 mm/h). The rainfall simulator of Wageningen was used, using sand as splash erosion source. Differences in the infiltration were also measured, and a calibration of sizes and speeds of the raindrops was done using the photography method (Hamidreza-Sadeghi et al., 2013). The splash devices selected for this study were unbounded splash devices (like the funnel, the cup (Fernandez-Raga et al., 2010) and the splash flume (Jomaa et al., 2010)), and bounded devices that allow the calculation of splash rate, (like the new cup (Scholten et al., 2011) and the Morgan tray). The behaviour of different splash devices

  4. GASEOUS DISCHARGE DEVICE

    Science.gov (United States)

    Gow, J.D.

    1961-01-10

    An extremely compact two-terminal gaseous discharge device is described that is capable of producing neutrons in copious quantities, relatively high energy ions, intense x rays, and the like. Principal novelty resides in the provision of a crossed electric-magnetic field region in the discharge envelope that traps electrons and accelerates them to very high energies to provide an intense ionizing medium adjacent the anode of the device for ionizing gas therein with extremely high efficiency. In addition, the crossed-field trapping region holds the electrons close to the anode whereby the acceleration of ions to the cathode is not materially effected by the electron sheath and the ions assume substantially the full energy of the anodecathode potential drop. (auth)

  5. Anti-gravity device

    Science.gov (United States)

    Palsingh, S. (Inventor)

    1975-01-01

    An educational toy useful in demonstrating fundamental concepts regarding the laws of gravity is described. The device comprises a sphere 10 of radius r resting on top of sphere 12 of radius R. The center of gravity of sphere 10 is displaced from its geometrical center by distance D. The dimensions are so related that D((R+r)/r) is greater than r. With the center of gravity of sphere 10 lying on a vertical line, the device is in equilibrium. When sphere 10 is rolled on the surface of sphere 12 it will return to its equilibrium position upon release. This creates an illusion that sphere 10 is defying the laws of gravity. In reality, due to the above noted relationship of D, R, and r, the center of gravity of sphere 10 rises from its equilibrium position as it rolls a short distance up or down the surface of sphere 12.

  6. Localized environment characterization device

    KAUST Repository

    Alzain, Hashim

    2016-07-21

    Various apparatuses and methods are provided for measuring the likely environmental impact of a particular geographic location on power generation properties of potential solar installations at the particular location. In an example embodiment of one such apparatus, a measurement device is provided. The measurement device includes a base portion comprising a base frame element disposed on a plurality of supporting legs, and a top panel comprising a series of connected members and one or more measurement modules whose planar dimensions are defined by the series of connected members. The top panel is connected to the base portion by a joint such that the top panel can rotate about the joint, and a panel support element is configured to fasten the top panel immovably at a desired degree of rotation in relation to the base portion.

  7. Nuclear reactor safety device

    Science.gov (United States)

    Hutter, Ernest

    1986-01-01

    A safety device is disclosed for use in a nuclear reactor for axially repositioning a control rod with respect to the reactor core in the event of an upward thermal excursion. Such safety device comprises a laminated helical ribbon configured as a tube-like helical coil having contiguous helical turns with slidably abutting edges. The helical coil is disclosed as a portion of a drive member connected axially to the control rod. The laminated ribbon is formed of outer and inner laminae. The material of the outer lamina has a greater thermal coefficient of expansion than the material of the inner lamina. In the event of an upward thermal excursion, the laminated helical coil curls inwardly to a smaller diameter. Such inward curling causes the total length of the helical coil to increase by a substantial increment, so that the control rod is axially repositioned by a corresponding amount to reduce the power output of the reactor.

  8. Fractional-order devices

    CERN Document Server

    Biswas, Karabi; Caponetto, Riccardo; Mendes Lopes, António; Tenreiro Machado, José António

    2017-01-01

    This book focuses on two specific areas related to fractional order systems – the realization of physical devices characterized by non-integer order impedance, usually called fractional-order elements (FOEs); and the characterization of vegetable tissues via electrical impedance spectroscopy (EIS) – and provides readers with new tools for designing new types of integrated circuits. The majority of the book addresses FOEs. The interest in these topics is related to the need to produce “analogue” electronic devices characterized by non-integer order impedance, and to the characterization of natural phenomena, which are systems with memory or aftereffects and for which the fractional-order calculus tool is the ideal choice for analysis. FOEs represent the building blocks for designing and realizing analogue integrated electronic circuits, which the authors believe hold the potential for a wealth of mass-market applications. The freedom to choose either an integer- or non-integer-order analogue integrator...

  9. Thin film device applications

    CERN Document Server

    Kaur, Inderjeet

    1983-01-01

    Two-dimensional materials created ab initio by the process of condensation of atoms, molecules, or ions, called thin films, have unique properties significantly different from the corresponding bulk materials as a result of their physical dimensions, geometry, nonequilibrium microstructure, and metallurgy. Further, these characteristic features of thin films can be drasti­ cally modified and tailored to obtain the desired and required physical characteristics. These features form the basis of development of a host of extraordinary active and passive thin film device applications in the last two decades. On the one extreme, these applications are in the submicron dimensions in such areas as very large scale integration (VLSI), Josephson junction quantum interference devices, magnetic bubbles, and integrated optics. On the other extreme, large-area thin films are being used as selective coatings for solar thermal conversion, solar cells for photovoltaic conver­ sion, and protection and passivating layers. Ind...

  10. Bioelectronic Sensors and Devices

    Science.gov (United States)

    Reed, Mark

    Nanoscale electronic devices have recently enabled the ability to controllably probe biological systems, from the molecular to the cellular level, opening up new applications and understanding of biological function and response. This talk reviews some of the advances in the field, ranging from diagnostic and therapeutic applications, to cellular manipulation and response, to the emulation of biological response. In diagnostics, integrated nanodevice biosensors compatible with CMOS technology have achieved unprecedented sensitivity, enabling a wide range of label-free biochemical and macromolecule sensing applications down to femtomolar concentrations. These systems have demonstrated integrated assays of biomarkers at clinically important concentrations for both diagnostics and as a quantitative tool for drug design and discovery. Cellular level response can also be observed, including immune response function and dynamics. Finally, the field is beginning to create devices that emulate function, and the demonstration of a solid state artificial ion channel will be discussed.

  11. Inlet stratification device

    DEFF Research Database (Denmark)

    2014-01-01

    An inlet stratification (5) is adapted to be arranged vertically in a tank (1) during operation. The stratification device (5) comprises an inlet pipe (6) formed of a flexible porous material and having a lower and upper end. The lower end of the inlet pipe (6) is connected to a bottom cap (10......) with an inlet passage way (16). The upper end of the inlet pipe (6) is connected with a top cap (9). The top cap (9) and the bottom cap (10) are mutually connected by means of a wire (8) and the top cap (9) is configured as a floating device providing a buoyancy force larger than the downwardly directed force...... due to the wire (8), the inlet pipe (6) and any deposited on the above pass during operation....

  12. Organic photosensitive devices

    Science.gov (United States)

    Peumans, Peter; Forrest, Stephen R.

    2013-01-22

    A photoactive device is provided. The device includes a first electrode, a second electrode, and a photoactive region disposed between and electrically connected to the first and second electrodes. The photoactive region further includes an organic donor layer and an organic acceptor layer that form a donor-acceptor heterojunction. The mobility of holes in the organic donor region and the mobility of electrons in the organic acceptor region are different by a factor of at least 100, and more preferably a factor of at least 1000. At least one of the mobility of holes in the organic donor region and the mobility of electrons in the organic acceptor region is greater than 0.001 cm.sup.2/V-sec, and more preferably greater than 1 cm.sup.2/V-sec. The heterojunction may be of various types, including a planar heterojunction, a bulk heterojunction, a mixed heterojunction, and a hybrid planar-mixed heterojunction.

  13. Dielectrokinetic chromatography devices

    Science.gov (United States)

    Chirica, Gabriela S; Fiechtner, Gregory J; Singh, Anup K

    2014-12-16

    Disclosed herein are methods and devices for dielectrokinetic chromatography. As disclosed, the devices comprise microchannels having at least one perturber which produces a non-uniformity in a field spanning the width of the microchannel. The interaction of the field non-uniformity with a perturber produces a secondary flow which competes with a primary flow. By decreasing the size of the perturber the secondary flow becomes significant for particles/analytes in the nanometer-size range. Depending on the nature of a particle/analyte present in the fluid and its interaction with the primary flow and the secondary flow, the analyte may be retained or redirected. The composition of the primary flow can be varied to affect the magnitude of primary and/or secondary flows on the particles/analytes and thereby separate and concentrate it from other particles/analytes.

  14. Microelectromechanical reprogrammable logic device

    KAUST Repository

    Hafiz, Md Abdullah Al

    2016-03-29

    In modern computing, the Boolean logic operations are set by interconnect schemes between the transistors. As the miniaturization in the component level to enhance the computational power is rapidly approaching physical limits, alternative computing methods are vigorously pursued. One of the desired aspects in the future computing approaches is the provision for hardware reconfigurability at run time to allow enhanced functionality. Here we demonstrate a reprogrammable logic device based on the electrothermal frequency modulation scheme of a single microelectromechanical resonator, capable of performing all the fundamental 2-bit logic functions as well as n-bit logic operations. Logic functions are performed by actively tuning the linear resonance frequency of the resonator operated at room temperature and under modest vacuum conditions, reprogrammable by the a.c.-driving frequency. The device is fabricated using complementary metal oxide semiconductor compatible mass fabrication process, suitable for on-chip integration, and promises an alternative electromechanical computing scheme.

  15. Microelectromechanical safe arm device

    Science.gov (United States)

    Roesler, Alexander W [Tijeras, NM

    2012-06-05

    Microelectromechanical (MEM) apparatus and methods for operating, for preventing unintentional detonation of energetic components comprising pyrotechnic and explosive materials, such as air bag deployment systems, munitions and pyrotechnics. The MEM apparatus comprises an interrupting member that can be moved to block (interrupt) or complete (uninterrupt) an explosive train that is part of an energetic component. One or more latching members are provided that engage and prevent the movement of the interrupting member, until the one or more latching members are disengaged from the interrupting member. The MEM apparatus can be utilized as a safe and arm device (SAD) and electronic safe and arm device (ESAD) in preventing unintentional detonations. Methods for operating the MEM apparatus include independently applying drive signals to the actuators coupled to the latching members, and an actuator coupled to the interrupting member.

  16. Memristor: the illusive device

    KAUST Repository

    Salama, Khaled N.

    2012-05-03

    The memristor (M) is considered to be the fourth two-terminal passive element in electronics, alongside the resistor (R), the capacitor (C), and the inductor (L). Its existence was postulated in 1971 but its first implementation was reported in 2008. Where was it hiding all that time and what can we do with it? Come and learn how the memristor completes the roster of electronic devices much like a missing particle that physicists seek to complete their tableaus.

  17. High speed heterostructure devices

    CERN Document Server

    Beer, Albert C; Willardson, R K; Kiehl, Richard A; Sollner, T C L Gerhard

    1994-01-01

    Volume 41 includes an in-depth review of the most important, high-speed switches made with heterojunction technology. This volume is aimed at the graduate student or working researcher who needs a broad overview andan introduction to current literature. Key Features * The first complete review of InP-based HFETs and complementary HFETs, which promise very low power and high speed * Offers a complete, three-chapter review of resonant tunneling * Provides an emphasis on circuits as well as devices.

  18. Spintronics in nanoscale devices

    CERN Document Server

    Hedin, Eric R

    2013-01-01

    By exploiting the novel properties of quantum dots and nanoscale Aharonov-Bohm rings together with the electronic and magnetic properties of various semiconductor materials and graphene, researchers have conducted numerous theoretical and computational modeling studies and experimental tests that show promising behavior for spintronics applications. Spin polarization and spin-filtering capabilities and the ability to manipulate the electron spin state through external magnetic or electric fields have demonstrated the promise of workable nanoscale devices for computing and memory applications.

  19. Drugs and Devices

    Directory of Open Access Journals (Sweden)

    Gail A. Van Norman, MD

    2016-08-01

    Full Text Available The regulation of medical drugs and devices involves competing goals of assuring safety and efficacy while providing rapid movement of innovative therapies through the investigative and regulatory processes as quickly as possible. The United States and the European Union approach these challenges in different ways. Whereas the United States has always relied on a strictly centralized process through 1 agency, the Food and Drug Administration (FDA, the European Commission synchronized the regulations of 28 different countries as they combined to create the European Union. The FDA historically developed as a consumer protection agency, whereas the regulations from the European Commission arose out of a need to harmonize inter-state commercial interests while preserving national “autonomy.” Thus, whereas the FDA has the advantages of centralization and common rules, the European Union regulates medical drug and device approvals through a network of centralized and decentralized agencies throughout its member states. This study explores some of the similarities and differences in European and U.S. regulation of drugs and devices, and discusses challenges facing each.

  20. Thermophotovoltaic energy conversion device

    Science.gov (United States)

    Charache, Greg W.; Baldasaro, Paul F.; Egley, James L.

    1998-01-01

    A thermophotovoltaic device and a method for making the thermophotovoltaic device. The device includes an n-type semiconductor material substrate having top and bottom surfaces, a tunnel junction formed on the top surface of the substrate, a region of active layers formed on top of the tunnel junction and a back surface reflector (BSR). The tunnel junction includes a layer of heavily doped n-type semiconductor material that is formed on the top surface of the substrate and a layer of heavily doped p-type semiconductor material formed on the n-type layer. An optional pseudomorphic layer can be formed between the n-type and p-type layers. A region of active layers is formed on top of the tunnel junction. This region includes a base layer of p-type semiconductor material and an emitter layer of n-type semiconductor material. An optional front surface window layer can be formed on top of the emitter layer. An optional interference filter can be formed on top of the emitter layer or the front surface window layer when it is used.

  1. Large Helical Device project

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-05-01

    In this book, the results of the scientific research on the design, trial manufacture and manufacturing processes of the Large Helical Device which was constructed in National Institute for Fusion Science are summarized. The LHD is the largest helical device in the world, and the largest superconducting system in the world. It possesses the following features: the optimization of heliotron magnetic field coordination, the adoption of superconducting magnets for 2 helical magnetic field coils and 6 poloidal coils, the adoption of helical diverter which enables steady plasma experiment, the flexible specification as the experimental facility and so on. The construction has been carried out smoothly, and in March, 1998, first plasma was generated. The outline of the Large Helical Device project, the physical design, the equipment design, the research and development of superconductivity and low temperature system, the design and manufacture of the superconducting and low temperature systems, the design and manufacture of the power source and superconducting bus-line, vacuum vessel and others, electron cyclotron heating, neutral beam injection and ion cyclotron RF heating, measurement system, control and data processing, safety management, the theory and analysis of LHD plasma, the visualization of the result of theoretical analysis, the analysis of the experimental data, and the experiment plan are described. (K.I.)

  2. Novel Concepts for Device to Device Communication using Network Coding

    DEFF Research Database (Denmark)

    Pahlevani, Peyman; Hundebøll, Martin; Pedersen, Morten Videbæk

    2014-01-01

    Device-to-device communication is currently a hot research topic within 3GPP. Even though D2D communication has been part of previous ad hoc, meshed and sensor networks proposals, the main contribution by 3GPP is that the direct communication among two devices is carried out over a dynamically...

  3. [Medical Devices Law for anesthesiologists].

    Science.gov (United States)

    Regner, M

    2015-09-01

    The Medical Devices Law is a relatively new legal system, which has replaced the still well-known medical devices regulations in Germany. The Medical Devices Law in Germany is based on European directives, which have been translated into national law with the Medical Devices Act. The Medical Devices Act is a framework of regulations and incorporates a number of decrees that address specific topics within the medical devices directives and in turn individual regulations refer to guidelines and recommendations from other sources which provide detailed technical information on specific topics. Overall, the Medical Devices Act represents a very complex legal system, which needs to be permanently observed with respect to continuous updating and adjustment. In this article the design and the structure are described but most of all the article filters significant problem areas that need to be considered when using and operating medical devices, especially for anesthesiologists.

  4. Semiconductor radiation detectors. Device physics

    Energy Technology Data Exchange (ETDEWEB)

    Lutz, G. [Max-Planck-Institut fuer Physik, Muenchen (Germany)]|[Max-Planck-Institut fuer Extraterrestrische Physik, Garching (Germany). Semiconductor Lab.

    1999-07-01

    The following topics were dealt with: semiconductor radiation detectors, basic semiconductor structures, semiconductors, energy measurement, radiation-level measurement, position measurement, electronics of the readout function, detectors with intrinsic amplification, detector technology, device stability, radiation hardness and device simulation.

  5. Case outsourcing medical device reprocessing.

    Science.gov (United States)

    Haley, Deborah

    2004-04-01

    IN THE INTEREST OF SAVING MONEY, many hospitals are considering extending the life of some single-use medical devices by using medical device reprocessing programs. FACILITIES OFTEN LACK the resources required to meet the US Food and Drug Administration's tough quality assurance standards. BY OUTSOURCING, hospitals can reap the benefits of medical device reprocessing without assuming additional staffing and compliance burdens. OUTSOURCING enables hospitals to implement a medical device reprocessing program quickly, with no capital investment and minimal effort.

  6. 78 FR 1247 - Certain Electronic Devices, Including Wireless Communication Devices, Tablet Computers, Media...

    Science.gov (United States)

    2013-01-08

    ... COMMISSION Certain Electronic Devices, Including Wireless Communication Devices, Tablet Computers, Media... importation of certain electronic devices, including wireless communication devices, tablet computers, media... United States after importation of certain electronic devices, including wireless communication devices...

  7. 77 FR 58576 - Certain Wireless Communication Devices, Portable Music and Data Processing Devices, Computers...

    Science.gov (United States)

    2012-09-21

    ... COMMISSION Certain Wireless Communication Devices, Portable Music and Data Processing Devices, Computers, and... importation of certain wireless communication devices, portable music and data processing devices, computers... after importation of certain wireless communication devices, portable music and data processing devices...

  8. Portable Source Identification Device

    Energy Technology Data Exchange (ETDEWEB)

    Andersen, Eric S.; Samuel, Todd J.; Gervais, Kevin L.

    2005-08-01

    U.S. Customs and Border Protection (CBP) is the primary enforcement agency protecting the nation’s ports of entry. CBP is enhancing its capability to interdict the illicit import of nuclear and radiological materials and devices that may be used by terrorists. Pacific Northwest National Laboratory (PNNL) is providing scientific and technical support to CBP in their goal to enable rapid deployment of nuclear and radiation detection systems at U. S. ports of entry to monitor 100% of the incoming international traffic and cargo while not adversely impacting the operations or throughput of the ports. As the deployment of radiation detection systems proceeds, there is a need to adapt the baseline radiation portal monitor (RPM) system technology to operations at these diverse ports of entry. When screening produces an alarm in the primary inspection RPM, the alarming vehicle is removed from the flow of commerce and the alarm is typically confirmed in a secondary inspection RPM. The portable source identification device (PSID) is a radiation sensor panel (RSP), based on thallium-doped sodium iodide (NaI(Tl)) scintillation detector and gamma spectroscopic analysis hardware and software, mounted on a scissor lift on a small truck. The lift supports a box containing a commercial off-the-shelf (COTS) sodium iodide detector that provides real-time isotopic identification, including neutron detectors to interdict Weapons of Mass Destruction (WMD) and radiation dispersion devices (RDD). The scissor lift will lower the detectors to within a foot off the ground and raise them to approximately 24 feet in the air, allowing a wide vertical scanning range.

  9. Portable source identification device

    Science.gov (United States)

    Andersen, Eric S.; Samuel, Todd J.; Gervais, Kevin L.

    2005-05-01

    U.S. Customs and Border Protection (CBP) is the primary enforcement agency protecting the nation"s ports of entry. CBP is enhancing its capability to interdict the illicit import of nuclear and radiological materials and devices that may be used by terrorists. Pacific Northwest National Laboratory (PNNL) is providing scientific and technical support to CBP in their goal to enable rapid deployment of nuclear and radiation detection systems at U. S. ports of entry to monitor 100% of the incoming international traffic and cargo while not adversely impacting the operations or throughput of the ports. As the deployment of radiation detection systems proceeds, there is a need to adapt the baseline radiation portal monitor (RPM) system technology to operations at these diverse ports of entry. When screening produces an alarm in the primary inspection RPM, the alarming vehicle is removed from the flow of commerce and the alarm is typically confirmed in a secondary inspection RPM. The portable source identification device (PSID) is a radiation sensor panel (RSP), based on thallium-doped sodium iodide (NaI(Tl)) scintillation detector and gamma spectroscopic analysis hardware and software, mounted on a scissor lift on a small truck. The lift supports a box containing a commercial off-the-shelf (COTS) sodium iodide detector that provides real-time isotopic identification, including neutron detectors to interdict Weapons of Mass Destruction (WMD) and radiation dispersion devices (RDD). The scissor lift will lower the detectors to within a foot off the ground and raise them to approximately 24 feet (7.3 m) in the air, allowing a wide vertical scanning range.

  10. Temperature Measurement and Monitoring Devices

    Science.gov (United States)

    1988-08-01

    feasibility based on potential usefulness in clinical medicine ’ias explored. All information herein wasn obtained from literature rrv’iew only. No...measurements, applications for temperature measuring devices, and description of several modern body temperature monitoring devices (techniques). Finally...gynecology, drug therapy, and ophthalmology. TEMPERATURE SENSING DEVICES Hippocrates is believed to be the first person Lo associate body temperature as

  11. Superconducting quantum-interference devices

    Science.gov (United States)

    Peters, P. N.; Holdeman, L. B.

    1975-01-01

    Published document discusses devices which are based on weak-link Josephson elements that join superconductors. Links can take numerous forms, and circuitry utilizing links can perform many varied functions with unprecedented sensitivity. Theoretical review of Josephson's junctions include tunneling junctions, point contact devices, microbridges, and proximity-effect devices.

  12. A microfluidic device with pillars

    DEFF Research Database (Denmark)

    2014-01-01

    The invention provides a microfluidic device for mixing liquid reagents, the device comprises, a chip forming at least one reaction chamber between a bottom and a top and extending between an inlet and an outlet. To enable manufacturing from less rigid materials, the device comprises pillars...

  13. Modeling of graphene nanoribbon devices

    Science.gov (United States)

    Guo, Jing

    2012-08-01

    Recent advances in graphene nanoribbon (GNR) electronic devices provide a concrete context for developing simulation methods, comparing theories to experiments, and using simulations to explore device physics. We present a review on modeling of graphene nanoribbon devices, with an emphasis on electronic and magnetoresistive devices. Device modeling is reviewed in a synergistic perspective with GNR material properties, device characteristics, and circuit requirements. Similarity with and difference to carbon nanotube devices are discussed. Device modeling and simulation results are compared to experimental data, which underlines the importance of theory-experiment collaborations in this field. Importance of the GNR edges, which have a negative impact on the carrier mobility due to edge roughness but offer new possibilities of spintronic devices and edge doping, is emphasized. Advanced device modeling of GNRs needs to have the capability to describe GNR device physics, including three-dimensional electrostatics, quantum and atomistic scale effects, elastic and inelastic scattering processes, electron-electron interaction, edge chemistry, magnetic field modulation, and spintronic and thermoelectric device phenomena.

  14. Medical devices and patient safety.

    Science.gov (United States)

    Mattox, Elizabeth

    2012-08-01

    Errors related to health care devices are not well understood. Nurses in intensive care and progressive care environments can benefit from understanding manufacturer-related error and device-use error, the principles of human factors engineering, and the steps that can be taken to reduce risk of errors related to health care devices.

  15. Polycrystalline Cadmium Telluride Photovoltaic Devices

    Science.gov (United States)

    Gessert, Timothy A.; Bonnet, Dieter

    2015-10-01

    The following sections are included: * Introduction * Brief history of CdTe PV devices * Initial attempts towards commercial modules * Review of present commercial industry/device designs * General CdTe material properties * Layer-specific process description for superstrate CdTe devices * Where is the junction? * Considerations for large-scale deployment * Conclusions * Acknowledgements * References

  16. [Design of SCM inoculation device].

    Science.gov (United States)

    Qian, Mingli; Xie, Haiyuan

    2014-01-01

    The first step of bacilli culture is inoculation bacteria on culture medium. Designing a device to increase efficiency of inoculation is significative. The new device is controlled by SCM. The stepper motor can drive the culture medium rotating, accelerating, decelerating, overturn and suspending. The device is high practicability and efficient, let inoculation easy for operator.

  17. Mechanical device for tissue regeneration

    NARCIS (Netherlands)

    Herder, J.L.; Maij, E.

    2010-01-01

    The invention relates to a mechanical device for tissue- regeneration inside a patient, comprising means (2, 3) to place a scaffold for the tissue under mechanical stress. Said means comprise a first device-part (2) and a second device-part (3) which parts are arranged to be movable with respect to

  18. Three-dimensional cascaded system analysis of a 50 µm pixel pitch wafer-scale CMOS active pixel sensor x-ray detector for digital breast tomosynthesis

    Science.gov (United States)

    Zhao, C.; Vassiljev, N.; Konstantinidis, A. C.; Speller, R. D.; Kanicki, J.

    2017-03-01

    High-resolution, low-noise x-ray detectors based on the complementary metal-oxide-semiconductor (CMOS) active pixel sensor (APS) technology have been developed and proposed for digital breast tomosynthesis (DBT). In this study, we evaluated the three-dimensional (3D) imaging performance of a 50 µm pixel pitch CMOS APS x-ray detector named DynAMITe (Dynamic Range Adjustable for Medical Imaging Technology). The two-dimensional (2D) angle-dependent modulation transfer function (MTF), normalized noise power spectrum (NNPS), and detective quantum efficiency (DQE) were experimentally characterized and modeled using the cascaded system analysis at oblique incident angles up to 30°. The cascaded system model was extended to the 3D spatial frequency space in combination with the filtered back-projection (FBP) reconstruction method to calculate the 3D and in-plane MTF, NNPS and DQE parameters. The results demonstrate that the beam obliquity blurs the 2D MTF and DQE in the high spatial frequency range. However, this effect can be eliminated after FBP image reconstruction. In addition, impacts of the image acquisition geometry and detector parameters were evaluated using the 3D cascaded system analysis for DBT. The result shows that a wider projection angle range (e.g.  ±30°) improves the low spatial frequency (below 5 mm-1) performance of the CMOS APS detector. In addition, to maintain a high spatial resolution for DBT, a focal spot size of smaller than 0.3 mm should be used. Theoretical analysis suggests that a pixelated scintillator in combination with the 50 µm pixel pitch CMOS APS detector could further improve the 3D image resolution. Finally, the 3D imaging performance of the CMOS APS and an indirect amorphous silicon (a-Si:H) thin-film transistor (TFT) passive pixel sensor (PPS) detector was simulated and compared.

  19. Wafer-scale growth of highly textured piezoelectric thin films by pulsed laser deposition for micro-scale sensors and actuators

    NARCIS (Netherlands)

    Nguyen, M. D.; Tiggelaar, R.; Aukes, Thomas; Rijnders, G.; Roelof, G.

    2017-01-01

    Piezoelectric lead-zirconate-Titanate (PZT) thin films were deposited on 4-inch (111)Pt/Ti/SiO2/Si(001) wafers using large-Area pulsed laser deposition (PLD). This study was focused on the homogeneity in film thickness, microstructure, ferroelectric and piezoelectric properties of PZT thin films.

  20. Rules-based correction strategies setup on sub-micrometer line and space patterns for 200mm wafer scale SmartNIL process within an integration process flow

    Science.gov (United States)

    Teyssedre, H.; Landis, S.; Brianceau, P.; Mayr, M.; Thanner, C.; Laure, M.; Zorbach, W.; Eibelhuber, M.; Pain, L.; Chouiki, M.; Wimplinger, M.

    2017-03-01

    In this paper the rules-based correction strategies for the nanoimprint lithography (NIL) technology are addressed using complete Scanning Electron Microscopy (SEM) characterizations. Performed onto 200 mm wafers imprinted with the HERCULES NIL equipment platform, Critical Dimension (CD) uniformity analyses are used to measure the evolution of lines and spaces features dimensions from the master to 50 consecutive imprints. The work brings focus on sub micrometer resolution features with duty cycles from 3 to 7. The silicon masters were manufactured with 193 optical lithography and dry etching and were fully characterized prior to the imprint process. Repeatability tests were performed over 50 wafers for two different processes to collect statistical and comparative data. The data revealed that the CD evolutions can be modelled by quadratic functions with respect to the number of imprints and feature dimension (CD and pitch) on the master. These models are used to establish the rules-based corrections for lines arrays in the scope of nanoimprint master manufacturing, and it opens the discussion on the process monitoring through metrology for the nanoimprint soft stamp technologies.

  1. Cursor Control Device Characteristics

    Directory of Open Access Journals (Sweden)

    James Phillips

    2000-05-01

    Full Text Available An analysis of cursor positioning may provide guidelines for improvements in cursor control. Four experiments addressed efficiency of cursor control devices (Mouse, Digitising Pen, Accupoint, Trackball. Participants moved a cursor leftwards, upwards or rightwards, positioning it in large or small targets situated in near or far space on the computer screen. Cursor coordinates were sampled every 5 ms. The number of submovements and the proportion of time spent in deceleration were analysed. Participants could not plan movements controlled by an Accupoint. Cursor trajectories were more variable in near space for detachable manipulanda due to potential cartesian coordinate system incompatibilities

  2. COUNTERROTATING PLASMA DEVICE

    Science.gov (United States)

    Halbach, K.; Baker, W.R.; Veron, D.

    1963-07-01

    An ion-electron plasma device having a conductive, cylindrical casing provided with an axially directed magneticmirror-type field is described. An axially aligned tubular electrode is disposed at each end of the casing with oppositely directed radial electric fields provided between each electrode and the casing. Simultaneous pulses of gas, injected from the inner end of each of the electrodes, become ionized and oppositely rotating plasma bodies are formed. The magnetic mirrors repel the plasma bodies and cause them to collide in the region between the mirrors. The opposite directions of rotation of the plasma bodies cause very high currents to flow therebetween and consequent heating occurs. (AEC)

  3. Data mining mobile devices

    CERN Document Server

    Mena, Jesus

    2013-01-01

    With today's consumers spending more time on their mobiles than on their PCs, new methods of empirical stochastic modeling have emerged that can provide marketers with detailed information about the products, content, and services their customers desire.Data Mining Mobile Devices defines the collection of machine-sensed environmental data pertaining to human social behavior. It explains how the integration of data mining and machine learning can enable the modeling of conversation context, proximity sensing, and geospatial location throughout large communities of mobile users

  4. Nanotube resonator devices

    Science.gov (United States)

    Jensen, Kenneth J; Zettl, Alexander K; Weldon, Jeffrey A

    2014-05-06

    A fully-functional radio receiver fabricated from a single nanotube is being disclosed. Simultaneously, a single nanotube can perform the functions of all major components of a radio: antenna, tunable band-pass filter, amplifier, and demodulator. A DC voltage source, as supplied by a battery, can power the radio. Using carrier waves in the commercially relevant 40-400 MHz range and both frequency and amplitude modulation techniques, successful music and voice reception has been demonstrated. Also disclosed are a radio transmitter and a mass sensor using a nanotube resonator device.

  5. Electromechanical motion devices

    CERN Document Server

    Krause, Paul C; Pekarek, Steven D

    2012-01-01

    This text provides a basic treatment of modern electric machine analysis that gives readers the necessary background for comprehending the traditional applications and operating characteristics of electric machines-as well as their emerging applications in modern power systems and electric drives, such as those used in hybrid and electric vehicles. Through the appropriate use of reference frame theory, Electromagnetic Motion Devices, Second Edition introduces readers to field-oriented control of induction machines, constant-torque, and constant-power control of dc, permanent-magnet ac

  6. Autopulsed Mini Fluidic Device

    OpenAIRE

    Rachid KHELFAOUI; Boumedienne BENYOUCEF; Brahim, DENNAI; Abdelhak MAAZOUZI

    2007-01-01

    The fluidic oscillator is a new micro-scale actuator developed for flow control applications. Mixing in micro channels is an important problem because the flow is always laminar flow even though the velocity may be high. The principal constraints when designing a mixer are the flow rate required through that particular section of the micro-device, the fluid properties of the streams to be mixed and the desired level of mixing. This paper describes a new actuator for flow mixing applications w...

  7. Nanoscale Electronic Devices

    Science.gov (United States)

    Jing, Xiaoye

    Continuous downscaling in microelectronics has pushed conventional CMOS technology to its physical limits, while Moore's Law has correctly predicted the trend for decades, each step forward is accompanied with unprecedented technological difficulties and near-exponential increase in cost. At the same time, however, demands for low-power, low-cost and high-speed devices have never diminished, instead, even more stringent requirements have been imposed on device performances. It is therefore crucial to explore alternative materials and device architectures in order to alleviate the pressure caused by downscaling. To this end, we investigated two different approaches: (1) InSb nanowire based field effect transistors (NWFETs) and (2) single walled carbon nanotube (SWCNT) -- peptide nucleic acid (PNA) --SWCNT conjugate. Two types of InSb nanowires were synthesized by template-assisted electrochemistry and chemical vapor deposition (CVD) respectively. In both cases, NWFETs were fabricated by electron beam lithography (EBL) and crystallinity was confirmed by transmission electron microscopy (TEM) and selected area diffraction (SAD) patterns. For electrochemistry nanowire, ambipolar conduction was observed with strong p-type conduction, the effect of thermal annealing on the conductivity was analyzed, a NWFET model that took into consideration the underlapped region in top-gated NWFET was proposed. Hole mobility in the channel was calculated to be 292.84 cm2V-1s -1 with a density of 1.5x1017/cm3. For CVD nanowire, the diameter was below 40nm with an average of 20nm. Vapor-liquid-solid (VLS) process was speculated to be the mechanism responsible for nanowire growth. The efficient gate control was manifested by high ION/I OFF ratio which was on the order of 106 and a small inverse subthreshold slope (functionalized single walled carbon nanotubes to synthesize the conjugate and characterized its electrical properties. Negative differential resistance (NDR) was observed

  8. Graphene device and method of using graphene device

    Science.gov (United States)

    Bouchiat, Vincent; Girit, Caglar; Kessler, Brian; Zettl, Alexander K.

    2015-08-11

    An embodiment of a graphene device includes a layered structure, first and second electrodes, and a dopant island. The layered structure includes a conductive layer, an insulating layer, and a graphene layer. The electrodes are coupled to the graphene layer. The dopant island is coupled to an exposed surface of the graphene layer between the electrodes. An embodiment of a method of using a graphene device includes providing the graphene device. A voltage is applied to the conductive layer of the graphene device. Another embodiment of a method of using a graphene device includes providing the graphene device without the dopant island. A dopant island is placed on an exposed surface of the graphene layer between the electrodes. A voltage is applied to the conductive layer of the graphene device. A response of the dopant island to the voltage is observed.

  9. Clamp-mount device

    Science.gov (United States)

    Clark, K. H. (Inventor)

    1983-01-01

    A clamp-mount device is disclosed for mounting equipment to an associated I-beam and the like structural member of the type having oppositely extending flanges wherein the device comprises a base and a pair of oppositely facing clamping members carried diagonally on the base clamping flanges therebetween and having flange receiving openings facing one another. Lock means are carried diagonally by the base opposite the clamping members locking the flanges in the clamping members. A resilient hub is carried centrally of the base engaging and biasing a back side of the flanges maintaining tightly clamped and facilitating use on vertical as well as horizontal members. The base turns about the hub to receive the flanges within the clamping members. Equipment may be secured to the base by any suitable means such as bolts in openings. Slidable gate latches secure the hinged locks in an upright locking position. The resilient hub includes a recess opening formed in the base and a rubber-like pad carried in this opening being depressably and rotatably carried therein.

  10. Emissivity modulating electrochromic device

    Science.gov (United States)

    Demiryont, Hulya; Shannon, Kenneth C., III; Sheets, Judd

    2009-05-01

    The IR-ECDTM (Infra-Red ElectroChromic Device) variable emitance device (VED) is an all-solid-state monolithic vacuum deposited thin film system with a unique metamaterial IR transparent-electrode system which functions as an electrically controlled dimmable mirror in the IR region. The maximum reflectance corresponding to the bleached condition of the system is around 90% (low-e condition, e=0.1). The minimum reflectance reaches nearly zero in the colored condition of the system (high emittance, e=1). The average emissivity modulation of the IRECDTM is 0.7 in the 8-12 micron region, and at 9.7 micron (room temperature) it reaches a value of 0.9. Half and full emissivity modulations occur within 2 and10 minutes respectively. Because of its light weight (5g/m2), low voltage requirement (+/- 1 Volts), extremely good emissivity control properties (from 0 to 0.9 at 300K) and highly repeatable deposition process, the IR-ECDTM technology is very attractive for satellite thermal control applications. The IR-ECDTM has been under evaluation in a real space environment since March 8, 2007. This paper presents recent achievements of the IR-ECDTM including space test results.

  11. Carbon for sensing devices

    CERN Document Server

    Tagliaferro, Alberto

    2015-01-01

    This book reveals why carbon is playing such an increasingly prominent role as a sensing material. The various steps that transform a raw material in a sensing device are thoroughly presented and critically discussed.  The authors deal with all aspects of carbon-based sensors, starting from the various hybridization and allotropes of carbon, with specific focus on micro and nanosized carbons (e.g., carbon nanotubes, graphene) and their growth processes. The discussion then moves to the role of functionalization and the different routes to achieve it. Finally, a number of sensing applications in various fields are presented, highlighting the connection with the basic properties of the various carbon allotropes.  Readers will benefit from this book’s bottom-up approach, which starts from the local bonding in carbon solids and ends with sensing applications, linking the local hybridization of carbon atoms and its modification by functionalization to specific device performance. This book is a must-have in th...

  12. Carbon based prosthetic devices

    Energy Technology Data Exchange (ETDEWEB)

    Devlin, D.J.; Carroll, D.W.; Barbero, R.S.; Archuleta, T. [Los Alamos National Lab., NM (US); Klawitter, J.J.; Ogilvie, W.; Strzepa, P. [Ascension Orthopedics (US); Cook, S.D. [Tulane Univ., New Orleans, LA (US). School of Medicine

    1998-12-31

    This is the final report of a one-year, Laboratory Directed Research and Development (LDRD) project at the Los Alamos National Laboratory (LANL). The project objective was to evaluate the use of carbon/carbon-fiber-reinforced composites for use in endoprosthetic devices. The application of these materials for the metacarpophalangeal (MP) joints of the hand was investigated. Issues concerning mechanical properties, bone fixation, biocompatibility, and wear are discussed. A system consisting of fiber reinforced materials with a pyrolytic carbon matrix and diamond-like, carbon-coated wear surfaces was developed. Processes were developed for the chemical vapor infiltration (CVI) of pyrolytic carbon into porous fiber preforms with the ability to tailor the outer porosity of the device to provide a surface for bone in-growth. A method for coating diamond-like carbon (DLC) on the articulating surface by plasma-assisted chemical vapor deposition (CVD) was developed. Preliminary results on mechanical properties of the composite system are discussed and initial biocompatibility studies were performed.

  13. Reactor power monitoring device

    Energy Technology Data Exchange (ETDEWEB)

    Oda, Naotaka; Igawa, Shinji; Kitazono, Hideaki

    1998-02-13

    The present invention provides a reactor power monitoring device capable of ensuring circumstance resistance, high reliability and high speed transmission even if an APRM is disposed in a reactor building (R/B). Namely, signal processing sections (APRM) for transmitting data to a central control chamber are distributed in the reactor building at an area at the lowest temperature among areas where the temperature control in an emergency state is regulated, and a transmission processing section (APRM-I/F) for transmitting data to the other systems is disposed to the central control chamber. An LPRM signal transmission processing section is constituted such that LPRM signals can be transmitted at a high speed by DMA. Set values relevant to reactor tripping (neutron flux high, thermal output high and sudden reduction of a reactor core flow rate) are stored in the APRM-I/F, and reactor tripping calculation is conducted in the APRM-I/F. With such procedure, a reactor power monitoring device having enhanced control function can be attained. (N.H.)

  14. Micro-Organ Device

    Science.gov (United States)

    Gonda, Steve R. (Inventor); Chang, Robert C. (Inventor); Starly, Binil (Inventor); Culbertson, Christopher (Inventor); Holtorf, Heidi L. (Inventor); Sun, Wei (Inventor); Leslie, Julia (Inventor)

    2013-01-01

    A method for fabricating a micro-organ device comprises providing a microscale support having one or more microfluidic channels and one or more micro-chambers for housing a micro-organ and printing a micro-organ on the microscale support using a cell suspension in a syringe controlled by a computer-aided tissue engineering system, wherein the cell suspension comprises cells suspended in a solution containing a material that functions as a three-dimensional scaffold. The printing is performed with the computer-aided tissue engineering system according to a particular pattern. The micro-organ device comprises at least one micro-chamber each housing a micro-organ; and at least one microfluidic channel connected to the micro-chamber, wherein the micro-organ comprises cells arranged in a configuration that includes microscale spacing between portions of the cells to facilitate diffusion exchange between the cells and a medium supplied from the at least one microfluidic channel.

  15. Single molecule logical devices.

    Science.gov (United States)

    Renaud, Nicolas; Hliwa, Mohamed; Joachim, Christian

    2012-01-01

    After almost 40 years of development, molecular electronics has given birth to many exciting ideas that range from molecular wires to molecular qubit-based quantum computers. This chapter reviews our efforts to answer a simple question: how smart can a single molecule be? In our case a molecule able to perform a simple Boolean function is a child prodigy. Following the Aviram and Ratner approach, these molecules are inserted between several conducting electrodes. The electronic conduction of the resulting molecular junction is extremely sensitive to the chemical nature of the molecule. Therefore designing this latter correctly allows the implementation of a given function inside the molecular junction. Throughout the chapter different approaches are reviewed, from hybrid devices to quantum molecular logic gates. We particularly stress that one can implement an entire logic circuit in a single molecule, using either classical-like intramolecular connections, or a deformation of the molecular orbitals induced by a conformational change of the molecule. These approaches are radically different from the hybrid-device approach, where several molecules are connected together to build the circuit.

  16. Fluid flow monitoring device

    Science.gov (United States)

    McKay, Mark D.; Sweeney, Chad E.; Spangler, Jr., B. Samuel

    1993-01-01

    A flow meter and temperature measuring device comprising a tube with a body centered therein for restricting flow and a sleeve at the upper end of the tube to carry several channels formed longitudinally in the sleeve to the appropriate axial location where they penetrate the tube to allow pressure measurements and temperature measurements with thermocouples. The high pressure measurement is made using a channel penetrating the tube away from the body and the low pressure measurement is made at a location at the widest part of the body. An end plug seals the end of the device and holes at its upper end allow fluid to pass from the interior of the tube into a plenum. The channels are made by cutting grooves in the sleeve, the grooves widened at the surface of the sleeve and then a strip of sleeve material is welded to the grooves closing the channels. Preferably the sleeve is packed with powdered graphite before cutting the grooves and welding the strips.

  17. Liquid developer jetting device

    Energy Technology Data Exchange (ETDEWEB)

    Takano, Jun-ichi; Sasahara, Toshihiko; Nakamura, Manabu

    1996-02-06

    The liquid developer jetting device of the present invention comprises an air jetting nozzle for jetting pressurized air to an object to be tested. A liquid developer jetting nozzle is disposed near the air jetting nozzle for jetting a developer upwardly. The liquid developer jetting nozzle is situated in front of the air jetting nozzle for jetting the liquid developer in the direction perpendicular to the pressurized air jetted from the air jetting nozzle. In order to perform an penetration flaw detection test for an abut-welded portion of a drain nozzle disposed to the bottom of a reactor pressure vessel, the liquid developer jetting device is disposed in adjacent with the welded portion. Since the liquid developer jetted while dispersed from the developer jetting nozzle is further dispersed by the pressurized air from the air jetting nozzle, the density of the jetted the developer is made uniform despite of the short distance to the object to be tested. Accordingly, developing processing can be performed even in a restricted space. (I.N.).

  18. Deformable paper origami optoelectronic devices

    KAUST Repository

    He, Jr-Hau

    2017-01-19

    Deformable optoelectronic devices are provided, including photodetectors, photodiodes, and photovoltaic cells. The devices can be made on a variety of paper substrates, and can include a plurality of fold segments in the paper substrate creating a deformable pattern. Thin electrode layers and semiconductor nanowire layers can be attached to the substrate, creating the optoelectronic device. The devices can be highly deformable, e.g. capable of undergoing strains of 500% or more, bending angles of 25° or more, and/or twist angles of 270° or more. Methods of making the deformable optoelectronic devices and methods of using, e.g. as a photodetector, are also provided.

  19. Plasma devices for hydrocarbon reformation

    KAUST Repository

    Cha, Min Suk

    2017-02-16

    Plasma devices for hydrocarbon reformation are provided. Methods of using the devices for hydrocarbon reformation are also provided. The devices can include a liquid container to receive a hydrocarbon source, and a plasma torch configured to be submerged in the liquid. The plasma plume from the plasma torch can cause reformation of the hydrocarbon. The device can use a variety of plasma torches that can be arranged in a variety of positions in the liquid container. The devices can be used for the reformation of gaseous hydrocarbons and/or liquid hydrocarbons. The reformation can produce methane, lower hydrocarbons, higher hydrocarbons, hydrogen gas, water, carbon dioxide, carbon monoxide, or a combination thereof.

  20. Cybersecurity for Connected Diabetes Devices

    Science.gov (United States)

    Klonoff, David C.

    2015-01-01

    Diabetes devices are increasingly connected wirelessly to each other and to data-displaying reader devices. Threats to the accurate flow of information and commands may compromise the function of these devices and put their users at risk of health complications. Sound cybersecurity of connected diabetes devices is necessary to maintain confidentiality, integrity, and availability of the data and commands. Diabetes devices can be hacked by unauthorized agents and also by patients themselves to extract data that are not automatically provided by product software. Unauthorized access to connected diabetes devices has been simulated and could happen in reality. A cybersecurity standard designed specifically for connected diabetes devices will improve the safety of these products and increase confidence of users that the products will be secure. PMID:25883162

  1. Cybersecurity for Connected Diabetes Devices.

    Science.gov (United States)

    Klonoff, David C

    2015-04-16

    Diabetes devices are increasingly connected wirelessly to each other and to data-displaying reader devices. Threats to the accurate flow of information and commands may compromise the function of these devices and put their users at risk of health complications. Sound cybersecurity of connected diabetes devices is necessary to maintain confidentiality, integrity, and availability of the data and commands. Diabetes devices can be hacked by unauthorized agents and also by patients themselves to extract data that are not automatically provided by product software. Unauthorized access to connected diabetes devices has been simulated and could happen in reality. A cybersecurity standard designed specifically for connected diabetes devices will improve the safety of these products and increase confidence of users that the products will be secure. © 2015 Diabetes Technology Society.

  2. Polarization Perception Device

    Science.gov (United States)

    Whitehead, Victor S. (Inventor); Coulson, Kinsell L. (Inventor)

    1997-01-01

    A polarization perception device comprises a base and a polarizing filter having opposite broad sides and a centerline perpendicular thereto. The filter is mounted on the base for relative rotation and with a major portion of the area of the filter substantially unobstructed on either side. A motor on the base automatically moves the filter angularly about its centerline at a speed slow enough to permit changes in light transmission by virtue of such movement to be perceived as light-dark pulses by a human observer, but fast enough so that the light phase of each such pulse occurs prior to fading of the light phase image of the preceding pulse from the observer's retina. In addition to an observer viewing a scene in real time through the filter while it is so angularly moved, or instead of such observation, the scene can be photographed, filmed or taped by a camera whose lens is positioned behind the filter.

  3. Micromixing within microfluidic devices.

    Science.gov (United States)

    Capretto, Lorenzo; Cheng, Wei; Hill, Martyn; Zhang, Xunli

    2011-01-01

    Micromixing is a crucial process within microfluidic systems such as micro total analysis systems (μTAS). A state-of-art review on microstructured mixing devices and their mixing phenomena is given. The review first presents an overview of the characteristics of fluidic behavior at the microscale and their implications in microfluidic mixing processes. According to the two basic principles exploited to induce mixing at the microscale, micromixers are generally classified as being passive or active. Passive mixers solely rely on pumping energy, whereas active mixers rely on an external energy source to achieve mixing. Typical types of passive micromixers are discussed, including T- or Y-shaped, parallel lamination, sequential, focusing enhanced mixers, and droplet micromixers. Examples of active mixers using external forces such as pressure field, electrokinetic, dielectrophoretic, electrowetting, magneto-hydrodynamic, and ultrasound to assist mixing are presented. Finally, the advantages and disadvantages of mixing in a microfluidic environment are discussed.

  4. Analytic device including nanostructures

    KAUST Repository

    Di Fabrizio, Enzo M.

    2015-07-02

    A device for detecting an analyte in a sample comprising: an array including a plurality of pixels, each pixel including a nanochain comprising: a first nanostructure, a second nanostructure, and a third nanostructure, wherein size of the first nanostructure is larger than that of the second nanostructure, and size of the second nanostructure is larger than that of the third nanostructure, and wherein the first nanostructure, the second nanostructure, and the third nanostructure are positioned on a substrate such that when the nanochain is excited by an energy, an optical field between the second nanostructure and the third nanostructure is stronger than an optical field between the first nanostructure and the second nanostructure, wherein the array is configured to receive a sample; and a detector arranged to collect spectral data from a plurality of pixels of the array.

  5. Optically Reconfigurable Photonic Devices

    CERN Document Server

    Wang, Qian; Gholipour, Behrad; Wang, Chih-Ming; Yuan, Guanghui; Teng, Jinghua; Zheludev, Nikolay I

    2015-01-01

    Optoelectronic components with adjustable parameters, from variable-focal-length lenses to spectral filters that can change functionality upon stimulation, have enormous technological importance. Tuning of such components is conventionally achieved by either micro- or nano-mechanical actuation of their consitutive parts, stretching or application of thermal stimuli. Here we report a new dielectric metasurface platform for reconfigurable optical components that are created with light in a non-volatile and reversible fashion. Such components are written, erased and re-written as two-dimensional binary or grey-scale patterns into a nanoscale film of phase change material by inducing a refractive-index-changing phase-transition with tailored trains of femtosecond pulses. We combine germanium-antimony-tellurium-based films optimized for high-optical-contrast ovonic switching with a sub-wavelength-resolution optical writing process to demonstrate technologically relevant devices: visible-range reconfigurable bi-chr...

  6. Air bag restraint device

    Science.gov (United States)

    Marts, D.J.; Richardson, J.G.

    1995-10-17

    A rear-seat air bag restraint device is disclosed that prevents an individual, or individuals, from continuing violent actions while being transported in a patrol vehicle`s rear seat without requiring immediate physical contact by the law enforcement officer. The air bag is activated by a control switch in the front seat and inflates to independently restrict the amount of physical activity occurring in the rear seat of the vehicle while allowing the officer to safely stop the vehicle. The air bag can also provide the officer additional time to get backup personnel to aid him if the situation warrants it. The bag is inflated and maintains a constant pressure by an air pump. 8 figs.

  7. Air bag restraint device

    Science.gov (United States)

    Marts, Donna J.; Richardson, John G.

    1995-01-01

    A rear-seat air bag restraint device is disclosed that prevents an individual, or individuals, from continuing violent actions while being transported in a patrol vehicle's rear seat without requiring immediate physical contact by the law enforcement officer. The air bag is activated by a control switch in the front seat and inflates to independently restrict the amount of physical activity occurring in the rear seat of the vehicle while allowing the officer to safely stop the vehicle. The air bag can also provide the officer additional time to get backup personnel to aid him if the situation warrants it. The bag is inflated and maintains a constant pressure by an air pump.

  8. Autopulsed Mini Fluidic Device

    Directory of Open Access Journals (Sweden)

    Rachid KHELFAOUI

    2007-04-01

    Full Text Available The fluidic oscillator is a new micro-scale actuator developed for flow control applications. Mixing in micro channels is an important problem because the flow is always laminar flow even though the velocity may be high. The principal constraints when designing a mixer are the flow rate required through that particular section of the micro-device, the fluid properties of the streams to be mixed and the desired level of mixing. This paper describes a new actuator for flow mixing applications with nozzle size equal 1.18 mm. The gas diffusion, mixing is very important operation in the fields of nature and industry. Now, it is desired to improve the mixing. In this paper, first the performance of fluidic oscillator mixer operated by gas is made clear simulation.

  9. Light emitting ceramic device

    Science.gov (United States)

    Valentine, Paul; Edwards, Doreen D.; Walker, Jr., William John; Slack, Lyle H.; Brown, Wayne Douglas; Osborne, Cathy; Norton, Michael; Begley, Richard

    2010-05-18

    A light-emitting ceramic based panel, hereafter termed "electroceramescent" panel, is herein claimed. The electroceramescent panel is formed on a substrate providing mechanical support as well as serving as the base electrode for the device. One or more semiconductive ceramic layers directly overlay the substrate, and electrical conductivity and ionic diffusion are controlled. Light emitting regions overlay the semiconductive ceramic layers, and said regions consist sequentially of a layer of a ceramic insulation layer and an electroluminescent layer, comprised of doped phosphors or the equivalent. One or more conductive top electrode layers having optically transmissive areas overlay the light emitting regions, and a multi-layered top barrier cover comprising one or more optically transmissive non-combustible insulation layers overlay said top electrode regions.

  10. QoE-Aware Device-to-Device Multimedia Communications

    Directory of Open Access Journals (Sweden)

    Liang ZHOU

    2015-08-01

    Full Text Available Multimedia services over mobile device-to-device (D2D networks has recently received considerable attention. In this scenario, each device is equipped with a cellular communication interface, as well as a D2D interface over a shared medium. In this work, we study the performance properties of the mobile D2D communications in the framework of user satisfaction, and develop a fully distributed QoE-aware multimedia communication scheme (QAMCS. Specifically, we translate the opportunistic multimedia communications issue into a stochastic optimization problem, which opens up a new degree of performance to exploit. Moreover, QAMCS is designed for a heterogeneous and dynamic environment, in which user demand, device mobility, and transmission fashion may vary across different devices and applications. Importantly, QAMCS is able to maximize the user satisfaction and only needs each device to implement its own scheme individually in the absence of a central controller.

  11. Digital forensics for handheld devices

    CERN Document Server

    Doherty, Eamon P

    2012-01-01

    Approximately 80 percent of the world's population now owns a cell phone, which can hold evidence or contain logs about communications concerning a crime. Cameras, PDAs, and GPS devices can also contain information related to corporate policy infractions and crimes. Aimed to prepare investigators in the public and private sectors, Digital Forensics for Handheld Devices examines both the theoretical and practical aspects of investigating handheld digital devices. This book touches on all areas of mobile device forensics, including topics from the legal, technical, academic, and social aspects o

  12. Fibre Optic Communication Key Devices

    CERN Document Server

    Grote, Norbert

    2012-01-01

    The book gives an in-depth description of the key devices of current and next generation fibre optic communication networks. In particular, the book covers devices such as semiconductor lasers, optical amplifiers, modulators, wavelength filters, and detectors but the relevant properties of optical fibres as well. The presentations include the physical principles underlying the various devices, the technologies used for the realization of the different devices, typical performance characteristics and limitations, and development trends towards more advanced components are also illustrated. Thus the scope of the book spans relevant principles, state-of-the-art implementations, the status of current research and expected future components.

  13. Mobile device security for dummies

    CERN Document Server

    Campagna, Rich; Krishnan, Ashwin

    2011-01-01

    The information you need to avoid security threats on corporate mobile devices Mobile devices have essentially replaced computers for corporate users who are on the go and there are millions of networks that have little to no security. This essential guide walks you through the steps for securing a network and building a bulletproof framework that will protect and support mobile devices in the enterprise. Featuring real-world case scenarios, this straightforward guide shares invaluable advice for protecting mobile devices from the loss of sensitive and confidential corporate informati

  14. Hot gas handling device and motorized vehicle comprising the device

    NARCIS (Netherlands)

    Klein Geltink, J.; Beukers, A.; Van Tooren, M.J.L.; Koussios, S.

    2012-01-01

    The invention relates to a device for handling hot exhaust gasses discharged from an internal combustion engine. The device comprises a housing (2), enclosing a space (3) for transporting the exhaust gasses. The housing (2) is provided with an entrance - opening (4) for the exhaust gasses discharged

  15. 78 FR 34669 - Certain Electronic Devices, Including Wireless Communication Devices, Portable Music and Data...

    Science.gov (United States)

    2013-06-10

    ... COMMISSION Certain Electronic Devices, Including Wireless Communication Devices, Portable Music and Data..., California (``Apple''), from importing wireless communication devices, portable music and data processing... importation of certain electronic devices, including wireless communication devices, portable music and data...

  16. 77 FR 51571 - Certain Wireless Communication Devices, Portable Music and Data Processing Devices, Computers...

    Science.gov (United States)

    2012-08-24

    ... COMMISSION Certain Wireless Communication Devices, Portable Music and Data Processing Devices, Computers, and... communication devices, portable music and data processing devices, computers, and components thereof. The... and Data Processing Devices, Computers, and Components Thereof, DN 2910; the Commission is soliciting...

  17. Vehicle frame measurement device

    Energy Technology Data Exchange (ETDEWEB)

    Sarauer, A.J.

    1987-08-04

    This patent describes a vehicle frame and body measurement apparatus for use in realigning the structure of a damaged unibody vehicle the device having a longitudinal axis utilized in a horizontal plane the apparatus comprising means for measuring the vehicle body and frame comprising, (a) means for supporting a damaged motor vehicle in a fixed position, (b) an elongated rail on each side of the supporting means spaced apart a distance greater than the width of the supporting means and the width of the vehicle, (c) a vertical upright of a length exceeding the height of the motor vehicle slidably supported by each of the rails and having a vertical axis substantially perpendicular to the horizontal plane of the vehicle, (d) a vertically adjustable horizontal bar attached to each of the uprights, substantially perpendicular to both the longitudinal axis of the rails and the vertical axis of the uprights, (e) means for affixing the horizontal bar to the uprights so that the bar is vertically adjustable, the affixing means being provided with releasable means to permit adjustable horizontal extension of the horizontal bar and (f) at least one extendable measuring means attached to each vertical upright at its junction with its associated horizontal rail and adjustably extending along the horizontal rail, the free end of the measuring means having to releasably affix it to the rail.

  18. Simulation of semiconductor devices

    CERN Document Server

    Oriato, D

    2001-01-01

    cathode, made using an AIGaAs heterostructure step. Simulations show the importance of the insertion of a thin highly-doped layer between the transit region and the electron launcher in order to improve device operation. Chapter 5 is an introduction to Ill-nitrides, in particular GaN and its alloy ln-GaN. We outline the discrepancy in the elastic and piezoelectric parameters found in the literature. Strain, dislocations and piezoelectricity are presented as the main features of a InGaN/GaN system. In chapter 6 an extensive simulation of the dependence of the optical band gap of a single InGaN quantum well on the piezoelectric and spontaneous polarization is reported. Quantum Confined Stark Effect and screening mechanisms are found to play a major role. The simulation of a novel InGaN/GaN double quantum well LED is presented. A wide well is used to capture electrons that tunnels in a narrow well where they recombine with holes. Resonant asymmetric tunneling of electron and holes is used to increase the efficie...

  19. Temperature differential detection device

    Science.gov (United States)

    Girling, P.M.

    1986-04-22

    A temperature differential detection device for detecting the temperature differential between predetermined portions of a container wall is disclosed as comprising a Wheatstone bridge circuit for detecting resistance imbalance with a first circuit branch having a first elongated wire element mounted in thermal contact with a predetermined portion of the container wall, a second circuit branch having a second elongated wire element mounted in thermal contact with a second predetermined portion of a container wall with the wire elements having a predetermined temperature-resistant coefficient, an indicator interconnected between the first and second branches remote from the container wall for detecting and indicating resistance imbalance between the first and second wire elements, and connector leads for electrically connecting the wire elements to the remote indicator in order to maintain the respective resistance value relationship between the first and second wire elements. The indicator is calibrated to indicate the detected resistance imbalance in terms of a temperature differential between the first and second wall portions. 2 figs.

  20. Virtual MIMO Beamforming and Device Pairing Enabled by Device-to-Device Communications for Multidevice Networks

    Directory of Open Access Journals (Sweden)

    Yeonjin Jeong

    2017-01-01

    Full Text Available We consider a multidevice network with asymmetric antenna configurations which supports not only communications between an access point and devices but also device-to-device (D2D communications for the Internet of things. For the network, we propose the transmit and receive beamforming with the channel state information (CSI for virtual multiple-input multiple-output (MIMO enabled by D2D receive cooperation. We analyze the sum rate achieved by a device pair in the proposed method and identify the strategies to improve the sum rate of the device pair. We next present a distributed algorithm and its equivalent algorithm for device pairing to maximize the throughput of the multidevice network. Simulation results confirm the advantages of the transmit CSI and D2D cooperation as well as the validity of the distributive algorithm.

  1. Enteral nutrition access devices.

    Science.gov (United States)

    Kwon, Richard S; Banerjee, Subhas; Desilets, David; Diehl, David L; Farraye, Francis A; Kaul, Vivek; Mamula, Petar; Pedrosa, Marcos C; Rodriguez, Sarah A; Varadarajulu, Shyam; Song, Louis-Michel Wong Kee; Tierney, William M

    2010-08-01

    The ASGE Technology Committee provides reviews of existing, new, or emerging endoscopic technologies that have an impact on the practice of GI endoscopy. Evidence-based methodology is used, performing a MEDLINE literature search to identify pertinent clinical studies on the topic and a MAUDE (U.S. Food and Drug Administration Center for Devices and Radiological Health) database search to identify the reported complications of a given technology. Both are supplemented by accessing the "related articles" feature of PubMed and by scrutinizing pertinent references cited by the identified studies. Controlled clinical trials are emphasized, but, in many cases, data from randomized, controlled trials are lacking. In such situations, large case series, preliminary clinical studies, and expert opinions are used. Technical data are gathered from traditional and Web-based publications, proprietary publications, and informal communications with pertinent vendors. Technology Status Evaluation Reports are drafted by 1 or 2 members of the ASGE Technology Committee, reviewed and edited by the committee as a whole, and approved by the ASGE Governing Board. When financial guidance is indicated, the most recent coding data and list prices at the time of publication are provided. For this review, the MEDLINE database was searched through August 2009 for articles related to endoscopy in patients requiring enteral feeding access by using the keywords "endoscopy," "percutaneous," "gastrostomy," "jejunostomy," "nasogastric," "nasoenteric," "nasojejunal," "transnasal," "feeding tube," "enteric," and "button." Technology Status Evaluation Reports are scientific reviews provided solely for educational and informational purposes. Technology Status Evaluation Reports are not rules and should not be construed as establishing a legal standard of care or as encouraging, advocating, requiring, or discouraging any particular treatment or payment for such treatment. Copyright 2010 American Society

  2. Integrated Ultrasonic-Photonic Devices

    DEFF Research Database (Denmark)

    Barretto, Elaine Cristina Saraiva

    This thesis deals with the modeling, design, fabrication and characterization of integrated ultrasonic-photonic devices, with particular focus on the use of standard semiconductor materials such as GaAs and silicon. The devices are based on the use of guided acoustic waves to modulate the light...

  3. Satellite and acoustic tracking device

    KAUST Repository

    Berumen, Michael L.

    2014-02-20

    The present invention relates a method and device for tracking movements of marine animals or objects in large bodies of water and across significant distances. The method and device can track an acoustic transmitter attached to an animal or object beneath the ocean surface by employing an unmanned surface vessel equipped with a hydrophone array and GPS receiver.

  4. Personalized Adaptation to Device Characteristics

    NARCIS (Netherlands)

    Herder, Eelco; van Dijk, Betsy; De Bra, Paul; Brusilovsky, Peter; Conejo, Ricardo

    2002-01-01

    Device characteristics, such as screen size and means of interaction, and the context in which a device is used, seriously affect the user’s mental representation of an information environment and its intended use. We hypothesize that user characteristics are valuable resources for determining which

  5. Wireless Power for Mobile Devices

    NARCIS (Netherlands)

    Waffenschmidt, E.

    2011-01-01

    Wireless power transfer allows a convenient, easy to use battery charging of mobile phones and other mobile devices. No hassle with cables and plugs, just place the device on a pad and that’s it. Such asystem even has the potential to become a standard charging solution. Where are the limits for

  6. Mixing in a Microfluid Device

    DEFF Research Database (Denmark)

    Hjorth, Poul G.; Deryabin, Mikhail

    Mixing of fluids in microchannels cannot rely on turbulence since the flow takes place at extremly low Reynolds numbers. Various active and passive devices have been developed to induce mixing in microfluid flow devices. We describe here a model of an active mixer where a transverse periodic flow...

  7. Physics of amorphous semiconductor devices

    Energy Technology Data Exchange (ETDEWEB)

    Adler, D.

    1987-01-01

    This book contains 19 papers. Some of the titles are: Self-consistent modeling of amorphous silicon devices; Numerical modeling of thin film Si:H solar cells; Submicron device physics for numerical simulations; and Applications of amorphous silicon thin film transistors to linear arrays.

  8. Medical Device Safety - Multiple Languages

    Science.gov (United States)

    ... Are Here: Home → Multiple Languages → All Health Topics → Medical Device Safety URL of this page: https://medlineplus.gov/languages/ ... V W XYZ List of All Topics All Medical Device Safety - Multiple Languages To use the sharing features on ...

  9. Selection of Air Terminal Device

    DEFF Research Database (Denmark)

    Nielsen, Peter V.

    This paper discusses the selection of the air terminal device for the experiments and numerical prediction in the International Energy Agency Annex 20 work: Air Flow Pattern within Buildings,......This paper discusses the selection of the air terminal device for the experiments and numerical prediction in the International Energy Agency Annex 20 work: Air Flow Pattern within Buildings,...

  10. Ultrafast Spectroscopy of Semiconductor Devices

    DEFF Research Database (Denmark)

    Borri, Paola; Langbein, Wolfgang; Hvam, Jørn Marcher

    1999-01-01

    in information processing at high data transfer rates. The technique is based on single pulse propagation through the device, with pulse duration tunable from 150fs to 11ps, and the characterization of the pulse at the output of the device by measuring the total pulse energy, the real time profile...

  11. A Device with Learning Capability.

    Science.gov (United States)

    Sotina, N. M.; Burlai, Yu. P.

    The invention involves a device with learning capacity which contains input, storage, arithmetic and output units. In order to increase the number of recognizable patterns, facilitate replacement of one pattern by another, and also increase the speed of the device, the memory unit for the input field is connected to memory units for storage of…

  12. Device Applications of Nonlinear Dynamics

    CERN Document Server

    Baglio, Salvatore

    2006-01-01

    This edited book is devoted specifically to the applications of complex nonlinear dynamic phenomena to real systems and device applications. While in the past decades there has been significant progress in the theory of nonlinear phenomena under an assortment of system boundary conditions and preparations, there exist comparatively few devices that actually take this rich behavior into account. "Device Applications of Nonlinear Dynamics" applies and exploits this knowledge to make devices which operate more efficiently and cheaply, while affording the promise of much better performance. Given the current explosion of ideas in areas as diverse as molecular motors, nonlinear filtering theory, noise-enhanced propagation, stochastic resonance and networked systems, the time is right to integrate the progress of complex systems research into real devices.

  13. Surgical tools and medical devices

    CERN Document Server

    Jackson, Mark

    2016-01-01

    This new edition presents information and knowledge on the field of biomedical devices and surgical tools. The authors look at the interactions between nanotechnology, nanomaterials, design, modeling, and tools for surgical and dental applications, as well as how nanostructured surfaces can be created for the purposes of improving cell adhesion between medical devices and the human body. Each original chapter is revised in this second edition and describes developments in coatings for heart valves, stents, hip and knee joints, cardiovascular devices, orthodontic applications, and regenerative materials such as bone substitutes. There are also 8 new chapters that address: Microvascular anastomoses Inhaler devices used for pulmonary delivery of medical aerosols Surface modification of interference screws Biomechanics of the mandible (a detailed case study) Safety and medical devices The synthesis of nanostructured material Delivery of anticancer molecules using carbon nanotubes Nano and micro coatings for medic...

  14. Ergonomic material-handling device

    Science.gov (United States)

    Barsnick, Lance E.; Zalk, David M.; Perry, Catherine M.; Biggs, Terry; Tageson, Robert E.

    2004-08-24

    A hand-held ergonomic material-handling device capable of moving heavy objects, such as large waste containers and other large objects requiring mechanical assistance. The ergonomic material-handling device can be used with neutral postures of the back, shoulders, wrists and knees, thereby reducing potential injury to the user. The device involves two key features: 1) gives the user the ability to adjust the height of the handles of the device to ergonomically fit the needs of the user's back, wrists and shoulders; and 2) has a rounded handlebar shape, as well as the size and configuration of the handles which keep the user's wrists in a neutral posture during manipulation of the device.

  15. Pressurized waterproof case electronic device

    KAUST Repository

    Berumen, Michael L.

    2013-01-31

    A pressurized waterproof case for an electronic device is particularly adapted for fluid-tight containment and operation of a touch-screen electronic device or the like therein at some appreciable water depth. In one example, the case may be formed as an enclosure having an open top panel or face covered by a flexible, transparent membrane or the like for the operation of the touchscreen device within the case. A pressurizing system is provided for the case to pressurize the case and the electronic device therein to slightly greater than ambient in order to prevent the external water pressure from bearing against the transparent membrane and pressing it against the touch screen, thereby precluding operation of the touch screen device within the case. The pressurizing system may include a small gas cartridge or may be provided from an external source.

  16. Class 1 devices case studies in medical devices design

    CERN Document Server

    Ogrodnik, Peter J

    2014-01-01

    The Case Studies in Medical Devices Design series consists of practical, applied case studies relating to medical device design in industry. These titles complement Ogrodnik's Medical Device Design and will assist engineers with applying the theory in practice. The case studies presented directly relate to Class I, Class IIa, Class IIb and Class III medical devices. Designers and companies who wish to extend their knowledge in a specific discipline related to their respective class of operation will find any or all of these titles a great addition to their library. Class 1 Devices is a companion text to Medical Devices Design: Innovation from Concept to Market. The intention of this book, and its sister books in the series, is to support the concepts presented in Medical Devices Design through case studies. In the context of this book the case studies consider Class I (EU) and 510(k) exempt (FDA) . This book covers classifications, the conceptual and embodiment phase, plus design from idea to PDS. These title...

  17. High voltage semiconductor devices and methods of making the devices

    Energy Technology Data Exchange (ETDEWEB)

    Matocha, Kevin; Chatty, Kiran; Banerjee, Sujit

    2018-01-23

    A multi-cell MOSFET device including a MOSFET cell with an integrated Schottky diode is provided. The MOSFET includes n-type source regions formed in p-type well regions which are formed in an n-type drift layer. A p-type body contact region is formed on the periphery of the MOSFET. The source metallization of the device forms a Schottky contact with an n-type semiconductor region adjacent the p-type body contact region of the device. Vias can be formed through a dielectric material covering the source ohmic contacts and/or Schottky region of the device and the source metallization can be formed in the vias. The n-type semiconductor region forming the Schottky contact and/or the n-type source regions can be a single continuous region or a plurality of discontinuous regions alternating with discontinuous p-type body contact regions. The device can be a SiC device. Methods of making the device are also provided.

  18. High voltage semiconductor devices and methods of making the devices

    Energy Technology Data Exchange (ETDEWEB)

    Matocha, Kevin; Chatty, Kiran; Banerjee, Sujit

    2017-02-28

    A multi-cell MOSFET device including a MOSFET cell with an integrated Schottky diode is provided. The MOSFET includes n-type source regions formed in p-type well regions which are formed in an n-type drift layer. A p-type body contact region is formed on the periphery of the MOSFET. The source metallization of the device forms a Schottky contact with an n-type semiconductor region adjacent the p-type body contact region of the device. Vias can be formed through a dielectric material covering the source ohmic contacts and/or Schottky region of the device and the source metallization can be formed in the vias. The n-type semiconductor region forming the Schottky contact and/or the n-type source regions can be a single continuous region or a plurality of discontinuous regions alternating with discontinuous p-type body contact regions. The device can be a SiC device. Methods of making the device are also provided.

  19. The intrauterine device today.

    Science.gov (United States)

    Rioux, J E

    1993-10-01

    The intrauterine contraceptive device (IUD) is effective and reversible and has a high continuation rate. It can also be used within 7 days postcoitus. Developed separately by Richter, Grafenberg, and Ota between 1909 and 1934, the IUD gained popularity in the 1960s and 1970s with the introduction of the Margulies Spiral, the Lippes Loop, the Birnberg Bow, and the Dalkon Shield. The last proved dangerous, and the IUD became unpopular. The 4 IUDs which are available in Canada include the TCu-380S (GYNE T Slimline), the TCu-200, the NOVA-T, and the Progestasert. All are T shaped and medicated (copper or progesterone). The 1st and 3rd can be left in situ for 10 years; the 2nd, for 4 years; and the 4th, for 1 year. The NOVA-T has a copper wire with a silver core and is inserted with a unique pull-push technique. The Progestasert, which contains 38 mg of progesterone, releases 65 mcg of the hormone daily. The best candidate for IUD use is parous, but not pregnant, is in a stable monogamous relationship, and has a healthy reproductive tract and no history of ectopic pregnancy, sexually transmitted disease, pelvic inflammatory disease, undiagnosed genital bleeding, endometrial or cervical neoplasia, abnormal endometrial anatomy, compromised immune system, allergy to copper, or Wilson's Disease. The only infection related to the IUD is that associated with insertion. Such an infection is polymicrobial and involves the endogenous, cervicovaginal flora (primarily anaerobes). It is usually asymptomatic and contained by the immune system. 200 mg of Doxycycline can be given orally as a prophylactic 1 hour prior to insertion. A nonprescription, nonsteroidal, anti-inflammatory drug, also taken 1 hour before the procedure, will prevent pain and a vasovagal reaction. Paracervical anesthesia should be used. If the depth of the uterus is less than 6 cm or greater than 10 cm, another form of contraception should be used. Although little research is being done in Canada on new IUDs

  20. Ontology-Based Device Descriptions and Device Repository for Building Automation Devices

    Directory of Open Access Journals (Sweden)

    Dibowski Henrik

    2011-01-01

    Full Text Available Device descriptions play an important role in the design and commissioning of modern building automation systems and help reducing the design time and costs. However, all established device descriptions are specialized for certain purposes and suffer from several weaknesses. This hinders a further design automation, which is strongly needed for the more and more complex building automation systems. To overcome these problems, this paper presents novel Ontology-based Device Descriptions (ODDs along with a layered ontology architecture, a specific ontology view approach with virtual properties, a generic access interface, a triple store-based database backend, and a generic search mask GUI with underlying query generation algorithm. It enables a formal, unified, and extensible specification of building automation devices, ensures their comparability, and facilitates a computer-enabled retrieval, selection, and interoperability evaluation, which is essential for an automated design. The scalability of the approach to several ten thousand devices is demonstrated.

  1. Legislation to regulate medical devices.

    Science.gov (United States)

    Harris, M

    1975-01-01

    The history of medical device regulation began with the need to rid the marketplace of bogus inventions which were either harmful in themselves or harmful because they delayed meaningful treatment of illness. Since World War II, sophistication in medical technology and development of electronic and other types of medical devices has created a new need for regulation of safety and performance of devices used to cure and mitigate disease in man. The 1938 amendments to the Food, Drug, and Cosmetic Act gave FDA authority over labeling and advertising of devices, enforceable only after devices were marketed. In 1969 a study by an HEW commission documented the need for further legislation. The commission recommended three categories of medical devices: those requiring premarket clearance or scientific review, those for which standards could be established to protect the public, and those which are generally recognized as safe and for which nor standards would be necessary. In 1974 the Senate unanimously approved Senator Kennedy's "Medical Device Amendments of 1973" legislation which fulfills the recommendations of the HEW commission report. The House of Representatives failed to pass their version of the legislation in the 93rd Congress. Senator Kennedy re-introduced the bill in the 94th Congress and it passed the Senate in April 1975. Representative Rogers re-introduced an amended bill. The bill is expected to become law in 1975.

  2. Handheld ultrasound array imaging device

    Science.gov (United States)

    Hwang, Juin-Jet; Quistgaard, Jens

    1999-06-01

    A handheld ultrasound imaging device, one that weighs less than five pounds, has been developed for diagnosing trauma in the combat battlefield as well as a variety of commercial mobile diagnostic applications. This handheld device consists of four component ASICs, each is designed using the state of the art microelectronics technologies. These ASICs are integrated with a convex array transducer to allow high quality imaging of soft tissues and blood flow in real time. The device is designed to be battery driven or ac powered with built-in image storage and cineloop playback capability. Design methodologies of a handheld device are fundamentally different to those of a cart-based system. As system architecture, signal and image processing algorithm as well as image control circuit and software in this device is deigned suitably for large-scale integration, the image performance of this device is designed to be adequate to the intent applications. To elongate the battery life, low power design rules and power management circuits are incorporated in the design of each component ASIC. The performance of the prototype device is currently being evaluated for various applications such as a primary image screening tool, fetal imaging in Obstetrics, foreign object detection and wound assessment for emergency care, etc.

  3. High voltage MOSFET devices and methods of making the devices

    Energy Technology Data Exchange (ETDEWEB)

    Banerjee, Sujit; Matocha, Kevin; Chatty, Kiran

    2015-12-15

    A SiC MOSFET device having low specific on resistance is described. The device has N+, P-well and JFET regions extended in one direction (Y-direction) and P+ and source contacts extended in an orthogonal direction (X-direction). The polysilicon gate of the device covers the JFET region and is terminated over the P-well region to minimize electric field at the polysilicon gate edge. In use, current flows vertically from the drain contact at the bottom of the structure into the JFET region and then laterally in the X direction through the accumulation region and through the MOSFET channels into the adjacent N+ region. The current flowing out of the channel then flows along the N+ region in the Y-direction and is collected by the source contacts and the final metal. Methods of making the device are also described.

  4. Semiconductor-superconductor optoelectronic devices

    Science.gov (United States)

    Bouscher, Shlomi; Panna, Dmitry; Hayat, Alex

    2017-10-01

    Devices combining superconductors with semiconductors offer a wide range of applications, particularly in the growing field of quantum information processing. This is due to their ability to take advantage of both the extensive knowledge gathered in the field of semiconductors and the unique quantum properties of superconductors. This results in novel device concepts, such as structures generating and detecting entangled photon pairs as well as novel optical gain and laser realizations. In this review, we discuss the fundamental concepts and the underlying physical phenomena of superconductor-semiconductor optoelectronics as well as practical device implementations.

  5. Metallization for crossbar molecular devices

    Energy Technology Data Exchange (ETDEWEB)

    Deng, J; Hofbauer, W; Chandrasekhar, N; O' Shea, S J [Institute of Materials Research and Engineering, 3 Research Link, Singapore 117602 (Singapore)

    2007-04-18

    Self-assembled organic monolayer nanopore crossbar junctions were fabricated as a test structure for molecular electronics. The device yield, which is typically very low due to electrical shorting on top electrode deposition, is studied for different deposition parameters, and a clear improvement (up to 45% yield) is obtained by indirect deposition of silver electrodes on cooled substrates. Nevertheless, the yield fluctuates strongly from run to run ({approx}8% to {approx}45%), implying that reliable device fabrication remains challenging. We find a small number of devices (<1%) show switching behaviour in conductivity, presumably due to metal filaments.

  6. Metallization for crossbar molecular devices

    Science.gov (United States)

    Deng, J.; Hofbauer, W.; Chandrasekhar, N.; O'Shea, S. J.

    2007-04-01

    Self-assembled organic monolayer nanopore crossbar junctions were fabricated as a test structure for molecular electronics. The device yield, which is typically very low due to electrical shorting on top electrode deposition, is studied for different deposition parameters, and a clear improvement (up to 45% yield) is obtained by indirect deposition of silver electrodes on cooled substrates. Nevertheless, the yield fluctuates strongly from run to run (~8% to ~45%), implying that reliable device fabrication remains challenging. We find a small number of devices (<1%) show switching behaviour in conductivity, presumably due to metal filaments.

  7. Spin superfluid Josephson quantum devices

    Science.gov (United States)

    Takei, So; Tserkovnyak, Yaroslav; Mohseni, Masoud

    2017-04-01

    A macroscopic spintronic qubit based on spin superfluidity and spin Hall phenomena is proposed. This magnetic quantum information processing device realizes the spin-supercurrent analog of the superconducting phase qubit and allows for full electrical control and readout. We also show that an array of interacting magnetic phase qubits can realize a quantum annealer. These devices can be built through standard solid-state fabrication technology, allowing for scalability. However, the upper bound for the operational temperature can, in principle, be higher than the superconducting counterpart, as it is ultimately governed by the magnetic ordering temperatures, which could be much higher than the critical temperatures of the conventional superconducting devices.

  8. A TOUCH-SENSITIVE DEVICE

    DEFF Research Database (Denmark)

    2009-01-01

    The present invention relates to an optical touch-sensitive device and a method of determining a position and determining a position change of an object contacting an optical touch sensitive device. In particular, the present invention relates to an optical touch pad and a method of determining...... a position and determining a position change of an object contacting an optical touch pad. A touch-sensitive device, according to the present invention may comprise a light source, a touch- sensitive waveguide, a detector array, and a first light redirecting member, wherein at least a part of the light...

  9. Giant magneto-resistance devices

    CERN Document Server

    Hirota, Eiichi; Inomata, Koichiro

    2002-01-01

    This book deals with the application of giant magneto-resistance (GMR) effects to electronic devices. It will appeal to engineers and graduate students in the fields of electronic devices and materials. The main subjects are magnetic sensors with high resolution and magnetic read heads with high sensitivity, required for hard-disk drives with recording densities of several gigabytes. Another important subject is novel magnetic random-access memories (MRAM) with non-volatile non-destructive and radiation-resistant characteristics. Other topics include future GMR devices based on bipolar spin transistors, spin field-effect transistors (FETs) and double-tunnel junctions.

  10. 78 FR 58785 - Unique Device Identification System

    Science.gov (United States)

    2013-09-24

    ... medical device regulations. The term ``commercial distribution'' is defined by Sec. 807.3(b) and we intend... adequately identify devices through distribution and use. This rule requires the label of medical devices to... rule requires the label and device package of each medical device to include a UDI and requires that...

  11. 16 CFR 1507.8 - Wheel devices.

    Science.gov (United States)

    2010-01-01

    ... 16 Commercial Practices 2 2010-01-01 2010-01-01 false Wheel devices. 1507.8 Section 1507.8... FIREWORKS DEVICES § 1507.8 Wheel devices. Drivers in fireworks devices commonly known as “wheels” shall be... operation. Wheel devices intended to operate in a fixed location shall be designed in such a manner that the...

  12. Wireless devices in nursing education

    Directory of Open Access Journals (Sweden)

    Ana Belén Sánchez-García

    2013-03-01

    Full Text Available Objective. This article sought to explore the adoption of wireless devices in university nursing teaching and address their repercussion on future professionals. Methodology. This is a bibliographical study conducted in 2011, which analyzed international publications on the use, review, application, opinion, and experimentation of wireless devices in university nursing teaching of wireless technology in nursing teaching. The following databases were used: Medline and Science@Direct. Results. A total of 503 articles were extracted and 77 were selected, of which 40 investigated the Personal Digital Assistant (PDA, 13 the clicker (Student Response Wireless System, and six the smart phone. The use of mobile devices has experienced strong growth during the last five years, especially PDAs. Conclusion. Use of mobile devices in university nursing teaching has grown in recent years, especially PDAs

  13. Silicon photonics fundamentals and devices

    CERN Document Server

    Deen, M Jamal

    2012-01-01

    The creation of affordable high speed optical communications using standard semiconductor manufacturing technology is a principal aim of silicon photonics research. This would involve replacing copper connections with optical fibres or waveguides, and electrons with photons. With applications such as telecommunications and information processing, light detection, spectroscopy, holography and robotics, silicon photonics has the potential to revolutionise electronic-only systems. Providing an overview of the physics, technology and device operation of photonic devices using exclusively silicon and related alloys, the book includes: * Basic Properties of Silicon * Quantum Wells, Wires, Dots and Superlattices * Absorption Processes in Semiconductors * Light Emitters in Silicon * Photodetectors , Photodiodes and Phototransistors * Raman Lasers including Raman Scattering * Guided Lightwaves * Planar Waveguide Devices * Fabrication Techniques and Material Systems Silicon Photonics: Fundamentals and Devices outlines ...

  14. Computer Independent Data Transfer Device

    Directory of Open Access Journals (Sweden)

    Darshana Rarath

    2017-07-01

    Full Text Available In today’s era, transferring data among distinct storage devices has become one of the tasks which are done most frequently. In order to make data and information omnipresent, it needs to be shared anywhere and anytime. However the reliance of user on a PC or laptop for the same is not efficient. This paper is about the innovative way to overcome this restriction. This paper discusses the development of a portable device with the use of wired and wireless communication applications to share data and information among distinct storage devices without relying on a PC or a laptop. The proposed device is compact, comprises of a touch screen, power source and is capable of transferring all types of files. Hence, it eliminates the dependence on a PC or a laptop for transferring data.

  15. Mechatronic Device for Locomotor Training

    Directory of Open Access Journals (Sweden)

    Duda Sławomir

    2016-12-01

    Full Text Available This paper presents a novel mechatronic device to support a gait reeducation process. The conceptual works were done by the interdisciplinary design team. This collaboration allowed to perform a device that would connect the current findings in the fields of biomechanics and mechatronics. In the first part of the article shown a construction of the device which is based on the structure of an overhead travelling crane. The rest of the article contains the issues related to machine control system. In the prototype, the control of drive system is conducted by means of two RT-DAC4/PCI real time cards connected with a signal conditioning interface. Authors present the developed control algorithms and optimization process of the controller settings values. The summary contains a comparison of some numerical simulation results and experimental data from the sensors mounted on the device. The measurement data were obtained during the gait of a healthy person.

  16. Device for measuring electric fields

    Science.gov (United States)

    Levine, S. H.; Harrison, S. R.

    1972-01-01

    Measurement of low-intensity electric fields in space and in presence of weak magnetic fields is accomplished by utilizing a device which permits determination of the extent a beam of cesium ions is deflected by an electric field.

  17. Heart failure - surgeries and devices

    Science.gov (United States)

    ... surgery; HF - surgery; Intra-aortic balloon pumps - heart failure; IABP - heart failure; Catheter based assist devices - heart failure ... problem may cause heart failure or make heart failure worse. Heart valve surgery may be needed to repair or ...

  18. #DDOD: Establishment Registration & Device Listing

    Data.gov (United States)

    U.S. Department of Health & Human Services — SUMMARY DDOD use case to request means on consolidating multiple data sources (MDR, PMA, 510(k), R&L) in order to build a list of all marketed medical devices....

  19. Polymer electronic devices and materials.

    Energy Technology Data Exchange (ETDEWEB)

    Schubert, William Kent; Baca, Paul Martin; Dirk, Shawn M.; Anderson, G. Ronald; Wheeler, David Roger

    2006-01-01

    Polymer electronic devices and materials have vast potential for future microsystems and could have many advantages over conventional inorganic semiconductor based systems, including ease of manufacturing, cost, weight, flexibility, and the ability to integrate a wide variety of functions on a single platform. Starting materials and substrates are relatively inexpensive and amenable to mass manufacturing methods. This project attempted to plant the seeds for a new core competency in polymer electronics at Sandia National Laboratories. As part of this effort a wide variety of polymer components and devices, ranging from simple resistors to infrared sensitive devices, were fabricated and characterized. Ink jet printing capabilities were established. In addition to promising results on prototype devices the project highlighted the directions where future investments must be made to establish a viable polymer electronics competency.

  20. Child restraint device loaner programs

    Science.gov (United States)

    1981-06-01

    The child restraint device (CRD) loaner programs in Tennessee were evaluated. In-Lerviews were conducted with loaner program clients in Memphis, Chattanooga, and Knoxville. Administrators of programs in all three sites also were interviewed. The prog...

  1. Nanomechanical Water Purification Device Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Seldon Laboratories, LLC, proposes a lightweight, low-pressure water filtration device that harnesses the unique properties of nanoparticles to destroy or remove...

  2. Nanomechanical Water Purification Device Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Seldon Laboratories, LLC, proposes a lightweight, low-pressure water purification device that harnesses the unique properties of carbon nanotubes and will operate...

  3. Microfluidics Device Simulation in MATLAB

    Science.gov (United States)

    Foreman, Michael; Shirk, Kathryn

    Microfluidics fluid channels have different dominant properties of flow than do macrofluidic channels. At small channel sizes, the calculations that model the fluid flow need to include slip velocity at the walls of the channel, the mean free path of particles, and other factors that can be difficult to compute. In order to reduce the potential for error and provide meaningful graphical representations of the computations, a computer program can be implemented. We are creating a MATLAB program suite to perform the relevant calculations quickly and accurately. Additionally, by building on this program, the potential for testing new ideas for microfluidic devices can be realized. This would reduce the costs associated with prototyping microfluidic devices as devices can be modeled in software without the need for creating physical devices until the concepts are shown to be viable.

  4. Liquid-level sensing device

    Science.gov (United States)

    Goldfuss, G.T.

    1975-09-16

    This invention relates to a device for sensing the level of a liquid while preventing the deposition and accumulation of materials on the exterior surfaces thereof. Two dissimilar metal wires are enclosed within an electrical insulating material, the wires being joined together at one end to form a thermocouple junction outside the insulating material. Heating means is disposed within the electrical insulating material and maintains the device at a temperature substantially greater than that of the environment surrounding the device, the heating means being electrically insulated from the two dissimilar thermocouple wires. In addition, a metal sheath surrounds and contacts both the electrical insulating material and the thermocouple junction. Electrical connections are provided for connecting the heating means with a power source and for connecting the thermocouple wires with a device for sensing the electrical potential across the thermocouple junction. (auth)

  5. Nanochanneled Device and Related Methods

    Science.gov (United States)

    Ferrari, Mauro (Inventor); Liu, Xuewu (Inventor); Grattoni, Alessandro (Inventor); Fine, Daniel (Inventor); Goodall, Randy (Inventor); Hosali, Sharath (Inventor); Medema, Ryan (Inventor); Hudson, Lee (Inventor)

    2016-01-01

    A nanochannel delivery device and method of manufacturing and use. The nanochannel delivery device comprises an inlet, an outlet, and a nanochannel. The nanochannel may be oriented parallel to the primary plane of the nanochannel delivery device. The inlet and outlet may be in direct fluid communication with the nanochannel. Considerable advances have been made in the field oftherapeutic agent (e.g. drug) delivery technology over thelast three decades, resulting in many breakthroughs in clinicalmedicine. The creation of therapeutic agent deliverydevices that are capable of delivering therapeutic agents incontrolled ways is still a challenge. One of the majorrequirements for an implantable drug delivery device iscontrolled release of therapeutic agents, ranging from smalldrug molecules to larger biological molecules. It is particularlydesirable to achieve a continuous passive drug releaseprofile consistent with zero order kinetics whereby theconcentration of drug in the bloodstream remains constantthroughout an extended delivery period.These devices have the potential to improve therapeuticefficacy, diminish potentially life-threatening side effects,improve patient compliance, minimize the intervention ofhealthcare personnel, reduce the duration of hospital stays,and decrease the diversion of regulated drugs to abusiveuses.Nanochannel delivery devices may be used in drug deliveryproducts for the effective administration of drugs. Inaddition, nanochannel delivery devices can be used in otherapplications where controlled release of a substance overtime is needed. Embodiments of this invention comprise a nanochanneldelivery device having nanochannels within a structureconfigured to yield high mechanical strength and high flowrates. Various fabrication protocols may be used to form thenanochannel delivery device. Embodiments of the fabricateddevices feature horizontal nanochannel lay-out (e.g., thenanochannel is parallel to the primary plane of the device),high molecule

  6. Metal semiconductor contacts and devices

    CERN Document Server

    Cohen, Simon S; Einspruch, Norman G

    1986-01-01

    VLSI Electronics Microstructure Science, Volume 13: Metal-Semiconductor Contacts and Devices presents the physics, technology, and applications of metal-semiconductor barriers in digital integrated circuits. The emphasis is placed on the interplay among the theory, processing, and characterization techniques in the development of practical metal-semiconductor contacts and devices.This volume contains chapters that are devoted to the discussion of the physics of metal-semiconductor interfaces and its basic phenomena; fabrication procedures; and interface characterization techniques, particularl

  7. Biomedical devices and their applications

    CERN Document Server

    2004-01-01

    This volume introduces readers to the basic concepts and recent advances in the field of biomedical devices. The text gives a detailed account of novel developments in drug delivery, protein electrophoresis, estrogen mimicking methods and medical devices. It also provides the necessary theoretical background as well as describing a wide range of practical applications. The level and style make this book accessible not only to scientific and medical researchers but also to graduate students.

  8. Trustworthy execution on mobile devices

    CERN Document Server

    Vasudevan, Amit; Newsome, James

    2013-01-01

    This brief considers the various stakeholders in today's mobile device ecosystem, and analyzes why widely-deployed hardware security primitives on mobile device platforms are inaccessible to application developers and end-users. Existing proposals are also evaluated for leveraging such primitives, and proves that they can indeed strengthen the security properties available to applications and users, without reducing the properties currently enjoyed by OEMs and network carriers. Finally, this brief makes recommendations for future research that may yield practical and deployable results.

  9. A drilling instrument centering device

    Energy Technology Data Exchange (ETDEWEB)

    Remizov, M.I.; Bogomazov, L.D.; Dudkin, M.P.; Kaplun, V.A.; Surma, K.Yu.

    1982-01-01

    A drilling instrument centering device is proposed which contains a body with fins, upper and lower wedge compression elements installed with the capability of interacting with the body, and a subassembly for locking the compression elements. To simplify the assembly and disassembly of the centering device, the upper and lower compressing elements are rigidly linked. The body is made of two parts, while the subassembly for locking the compressing elements is made in the form of a spring installed between the body parts.

  10. Lightweight cryptography for constrained devices

    DEFF Research Database (Denmark)

    Alippi, Cesare; Bogdanov, Andrey; Regazzoni, Francesco

    2014-01-01

    Lightweight cryptography is a rapidly evolving research field that responds to the request for security in resource constrained devices. This need arises from crucial pervasive IT applications, such as those based on RFID tags where cost and energy constraints drastically limit the solution...... complexity, with the consequence that traditional cryptography solutions become too costly to be implemented. In this paper, we survey design strategies and techniques suitable for implementing security primitives in constrained devices....

  11. Cable Driven Devices for Telemanipulation

    OpenAIRE

    Ferraresi, Carlo; Pescarmona, Francesco

    2010-01-01

    Cable driven robotic devices present peculiar aspects, requiring the solution of very specific problems. As regards the determination of the main operational characteristics, like the workspace, it is necessary to consider that such devices are often parallel and redundant structures. Moreover, cables can only exert traction forces. As a consequence, the development of such structures requires coping with two main aspects: (a) the solution of forward kinematics and inverse statics, necessary ...

  12. High speed serdes devices and applications

    CERN Document Server

    Stauffer, David R; Sorna, Michael A; Dramstad, Kent; Ogilvie, Clarence Rosser; Amanullah, Mohammad; Rockrohr, James Donald

    2008-01-01

    Offers an understanding of the features and functions typically found on HSS devices. This book explains how these HSS devices are used in protocol applications and the analysis which must be performed to use such HSS devices.

  13. Effects of Radiation on Commercial Power Devices

    Science.gov (United States)

    Selva, Luis; Becker, Heidi; Chavez, Rosa; Scheick, Leif

    2006-01-01

    The effects of radiation on various commercial power devices are presented. The devices have proved to be very fragile to single event effects, with some of the devices actually succumbing to catastrophic SEE with protons.

  14. 77 FR 70464 - Certain Electronic Devices, Including Wireless Communication Devices, Portable Music and Data...

    Science.gov (United States)

    2012-11-26

    ... From the Federal Register Online via the Government Publishing Office INTERNATIONAL TRADE COMMISSION Certain Electronic Devices, Including Wireless Communication Devices, Portable Music and Data... importation of certain electronic devices, including wireless communication devices, portable music and data...

  15. 78 FR 16865 - Certain Electronic Devices, Including Wireless Communication Devices, Portable Music and Data...

    Science.gov (United States)

    2013-03-19

    ... From the Federal Register Online via the Government Publishing Office INTERNATIONAL TRADE COMMISSION Certain Electronic Devices, Including Wireless Communication Devices, Portable Music and Data... importation of certain electronic devices, including wireless communication devices, portable music and data...

  16. 77 FR 60720 - Certain Electronic Devices, Including Wireless Commmunication Devices, Portable Music and Data...

    Science.gov (United States)

    2012-10-04

    ... From the Federal Register Online via the Government Publishing Office INTERNATIONAL TRADE COMMISSION Certain Electronic Devices, Including Wireless Commmunication Devices, Portable Music and Data... infringing electronic devices, including wireless communication devices, portable music and data processing...

  17. Wireless device monitoring methods, wireless device monitoring systems, and articles of manufacture

    Science.gov (United States)

    McCown, Steven H [Rigby, ID; Derr, Kurt W [Idaho Falls, ID; Rohde, Kenneth W [Idaho Falls, ID

    2012-05-08

    Wireless device monitoring methods, wireless device monitoring systems, and articles of manufacture are described. According to one embodiment, a wireless device monitoring method includes accessing device configuration information of a wireless device present at a secure area, wherein the device configuration information comprises information regarding a configuration of the wireless device, accessing stored information corresponding to the wireless device, wherein the stored information comprises information regarding the configuration of the wireless device, comparing the device configuration information with the stored information, and indicating the wireless device as one of authorized and unauthorized for presence at the secure area using the comparing.

  18. 76 FR 45860 - In the Matter of Certain Electronic Devices, Including Wireless Communication Devices, Portable...

    Science.gov (United States)

    2011-08-01

    ... communication devices, portable music and data processing devices, and tablet computers by reason of... communication devices, portable music and data processing devices, and tablet computers that infringe one or... COMMISSION In the Matter of Certain Electronic Devices, Including Wireless Communication Devices, Portable...

  19. 75 FR 10502 - In the Matter of Certain Electronic Devices, Including Handheld Wireless Communications Devices...

    Science.gov (United States)

    2010-03-08

    ... COMMISSION In the Matter of Certain Electronic Devices, Including Handheld Wireless Communications Devices...-TA-667 and 337-TA-673, Certain Electronic Devices Including Handheld Wireless Communications Devices... electronic devices, including handheld wireless communications devices by reason of infringement of certain...

  20. Resource management for device-to-device underlay communication

    CERN Document Server

    Song, Lingyang; Xu, Chen

    2013-01-01

    Device-to-Device (D2D) communication will become a key feature supported by next generation cellular networks, a topic of enormous importance to modern communication. Currently, D2D serves as an underlay to the cellular network as a means to increase spectral efficiency. Although D2D communication brings large benefits in terms of system capacity, it also causes interference as well as increased computation complexity to cellular networks as a result of spectrum sharing. Thus, efficient resource management must be performed to guarantee a target performance level of cellular communication.This

  1. Compact, Controlled Resistance Exercise Device

    Science.gov (United States)

    Paulus, David C.; DeWitt, John K.; Reich, Alton J.; Shaw, James E.; Deaconu, Stelu S.

    2011-01-01

    Spaceflight leads to muscle and bone atrophy. Isoinertial (free-weight) exercises provide a sufficient stimulus to elicit increases in both muscle strength and bone mineral density in Earth-based studies. While exercise equipment is in use on the International Space Station for crewmember health maintenance, current devices are too large to place in a transport vehicle or small spacecraft. Therefore, a portable computer controlled resistance exercise device is being developed that is able to simulate the inertial loading experienced when lifting a mass on Earth. This portable device weighs less than 50 lb and can simulate the resistance of lifting and lowering up to 600 lb of free-weights. The objective is to allow crewmembers to perform resistance exercise with loads capable of maintaining muscle and bone health. The device is reconfigurable and allows for the performance of typical Earth-based free-weight exercises. Forces exerted, volume of work, range of motion, time-under-tension, and speed/ acceleration of movement are recorded and can be remotely monitored to track progress and modify individual protocols based on exercise session data. A performance evaluation will be completed and data will be presented that include ground-reaction force comparisons between the device and free-weight dead-lifts over a spectrum of resistance levels. Movement biomechanics will also be presented.

  2. Inducer Hydrodynamic Load Measurement Devices

    Science.gov (United States)

    Skelley, Stephen E.; Zoladz, Thomas F.

    2002-01-01

    Marshall Space Flight Center (MSFC) has demonstrated two measurement devices for sensing and resolving the hydrodynamic loads on fluid machinery. The first - a derivative of the six component wind tunnel balance - senses the forces and moments on the rotating device through a weakened shaft section instrumented with a series of strain gauges. This "rotating balance" was designed to directly measure the steady and unsteady hydrodynamic loads on an inducer, thereby defining both the amplitude and frequency content associated with operating in various cavitation modes. The second device - a high frequency response pressure transducer surface mounted on a rotating component - was merely an extension of existing technology for application in water. MSFC has recently completed experimental evaluations of both the rotating balance and surface-mount transducers in a water test loop. The measurement bandwidth of the rotating balance was severely limited by the relative flexibility of the device itself, resulting in an unexpectedly low structural bending mode and invalidating the higher frequency response data. Despite these limitations, measurements confirmed that the integrated loads on the four-bladed inducer respond to both cavitation intensity and cavitation phenomena. Likewise, the surface-mount pressure transducers were subjected to a range of temperatures and flow conditions in a non-rotating environment to record bias shifts and transfer functions between the transducers and a reference device. The pressure transducer static performance was within manufacturer's specifications and dynamic response accurately followed that of the reference.

  3. MRI-powered biomedical devices.

    Science.gov (United States)

    Hovet, Sierra; Ren, Hongliang; Xu, Sheng; Wood, Bradford; Tokuda, Junichi; Tse, Zion Tsz Ho

    2017-11-16

    Magnetic resonance imaging (MRI) is beneficial for imaging-guided procedures because it provides higher resolution images and better soft tissue contrast than computed tomography (CT), ultrasound, and X-ray. MRI can be used to streamline diagnostics and treatment because it does not require patients to be repositioned between scans of different areas of the body. It is even possible to use MRI to visualize, power, and control medical devices inside the human body to access remote locations and perform minimally invasive procedures. Therefore, MR conditional medical devices have the potential to improve a wide variety of medical procedures; this potential is explored in terms of practical considerations pertaining to clinical applications and the MRI environment. Recent advancements in this field are introduced with a review of clinically relevant research in the areas of interventional tools, endovascular microbots, and closed-loop controlled MRI robots. Challenges related to technology and clinical feasibility are discussed, including MRI based propulsion and control, navigation of medical devices through the human body, clinical adoptability, and regulatory issues. The development of MRI-powered medical devices is an emerging field, but the potential clinical impact of these devices is promising.

  4. Survey of cryogenic semiconductor devices

    Energy Technology Data Exchange (ETDEWEB)

    Talarico, L.J.; McKeever, J.W.

    1996-04-01

    Improved reliability and electronic performance can be achieved in a system operated at cryogenic temperatures because of the reduction in mechanical insult and in disruptive effects of thermal energy on electronic devices. Continuing discoveries of new superconductors with ever increasing values of T{sub c} above that of liquid nitrogen temperature (LNT) have provided incentive for developing semiconductor electronic systems that may also operate in the superconductor`s liquid nitrogen bath. Because of the interest in high-temperature superconductor (HTS) devices, liquid nitrogen is the cryogen of choice and LNT is the temperature on which this review is focused. The purpose of this survey is to locate and assemble published information comparing the room temperature (298 K), performance of commercially available conventional and hybrid semiconductor device with their performance at LNT (77K), to help establish their candidacy as cryogenic electronic devices specifically for use at LNT. The approach to gathering information for this survey included the following activities. Periodicals and proceedings were searched for information on the behavior of semiconductor devices at LNT. Telephone calls were made to representatives of semiconductor industries, to semiconductor subcontractors, to university faculty members prominent for their research in the area of cryogenic semiconductors, and to representatives of the National Aeronautics and Space Administration (NASA) and NASA subcontractors. The sources and contacts are listed with their responses in the introduction, and a list of references appears at the end of the survey.

  5. Ion manipulation method and device

    Energy Technology Data Exchange (ETDEWEB)

    Anderson, Gordon A.; Baker, Erin M.; Smith, Richard D.; Ibrahim, Yehia M.

    2017-11-07

    An ion manipulation method and device is disclosed. The device includes a pair of substantially parallel surfaces. An array of inner electrodes is contained within, and extends substantially along the length of, each parallel surface. The device includes a first outer array of electrodes and a second outer array of electrodes. Each outer array of electrodes is positioned on either side of the inner electrodes, and is contained within and extends substantially along the length of each parallel surface. A DC voltage is applied to the first and second outer array of electrodes. A RF voltage, with a superimposed electric field, is applied to the inner electrodes by applying the DC voltages to each electrode. Ions either move between the parallel surfaces within an ion confinement area or along paths in the direction of the electric field, or can be trapped in the ion confinement area.

  6. Electrically tunable infrared metamaterial devices

    Science.gov (United States)

    Brener, Igal; Jun, Young Chul

    2015-07-21

    A wavelength-tunable, depletion-type infrared metamaterial optical device is provided. The device includes a thin, highly doped epilayer whose electrical permittivity can become negative at some infrared wavelengths. This highly-doped buried layer optically couples with a metamaterial layer. Changes in the transmission spectrum of the device can be induced via the electrical control of this optical coupling. An embodiment includes a contact layer of semiconductor material that is sufficiently doped for operation as a contact layer and that is effectively transparent to an operating range of infrared wavelengths, a thin, highly doped buried layer of epitaxially grown semiconductor material that overlies the contact layer, and a metallized layer overlying the buried layer and patterned as a resonant metamaterial.

  7. Networked Attached Devices at SNS

    CERN Document Server

    Blokland, W

    2003-01-01

    The Spallation Neutron Source (SNS) diagnostic instruments at Oak Ridge National Laboratory are based on the Network Attached Device (NAD) concept. Each pickup or sensor has its own resources such as timing, data acquisition and processing. NADs are individually connected to the network, thus reducing the brittleness inherent in tightly coupled systems. This architecture allows an individual device to fail or to be serviced or removed without disrupting other devices. This paper describes our implementation of the nearly 400 NADs to be deployed. The hardware consists of rack-mounted PCs with standard motherboards and PCI data-acquisition boards. The software environment is based on LabVIEW and EPICS. LabVIEW supports the agile development demanded by modern diagnostic systems. EPICS is the control system standard for the entire SNS facility. To achieve high performance, LabVIEW and EPICS communicate through shared memory. SNS diagnostics are developed by a multi-laboratory partnership including ORNL, BNL, LAN...

  8. Coherent exciton-polariton devices

    Science.gov (United States)

    Fraser, Michael D.

    2017-09-01

    The Bose-Einstein condensate of exciton-polaritons has emerged as a unique, coherent system for the study of non-equilibrium, macroscopically coherent Bose gases, while the full confinement of this coherent state to a semiconductor chip has also generated considerable interest in developing novel applications employing the polariton condensate, possibly even at room temperature. Such devices include low-threshold lasers, precision inertial sensors, and circuits based on superfluidity with ultra-fast non-linear elements. While the demonstration and development of such devices are at an early stage, rapid progress is being made. In this review, an overview of the exciton-polariton condensate system and the established and emerging material systems and fabrication techniques are presented, followed by a critical, in-depth assessment of the ability of the coherent polariton system to deliver on its promise of devices offering either new functionality and/or room-temperature operation.

  9. Fibre optic communication key devices

    CERN Document Server

    Grote, Norbert

    2017-01-01

    The book gives an in-depth description of key devices of current and next generation fibre optic communication networks. Devices treated include semiconductor lasers, optical amplifiers, modulators, wavelength filters and other passives, detectors, all-optical switches, but relevant properties of optical fibres and network aspects are included as well. The presentations include the physical principles underlying the various devices, technologies used for their realization, typical performance characteristics and limitations, but development trends towards more advanced components are also illustrated. This new edition of a successful book was expanded and updated extensively. The new edition covers among others lasers for optical communication, optical switches, hybrid integration, monolithic integration and silicon photonics. The main focus is on Indium phosphide-based structures but silicon photonics is included as well. The book covers relevant principles, state-of-the-art implementations, status of curren...

  10. Linerless label device and method

    KAUST Repository

    Binladen, Abdulkari

    2016-01-14

    This apparatus and method for applying a linerless label to an end user product includes a device with a printer for printing on a face surface of a linerless label, and a release coat applicator for applying a release coat to the face surface of the label; another device including an unwinder unit (103) to unwind a roll of printed linerless label; a belt (108); a glue applicator (102) for applying glue to the belt; a nip roller (106) for contacting and applying pressure to the face surface of the linerless label such that the glue on the belt transfers to the back surface of the linerless label; at least one slitting knife 105) positioned downstream the belt and a rewinder unit (104) positioned downstream the slitting knife; and a third device which die cuts and applies the linerless label to an end user object.

  11. Microelectroporation device for genomic screening

    Energy Technology Data Exchange (ETDEWEB)

    Perroud, Thomas D.; Renzi, Ronald F.; Negrete, Oscar; Claudnic, Mark R.

    2014-09-09

    We have developed an microelectroporation device that combines microarrays of oligonucleotides, microfluidic channels, and electroporation for cell transfection and high-throughput screening applications (e.g. RNA interference screens). Microarrays allow the deposition of thousands of different oligonucleotides in microscopic spots. Microfluidic channels and microwells enable efficient loading of cells into the device and prevent cross-contamination between different oligonucleotides spots. Electroporation allows optimal transfection of nucleic acids into cells (especially hard-to-transfect cells such as primary cells) by minimizing cell death while maximizing transfection efficiency. This invention has the advantage of a higher throughput and lower cost, while preventing cross-contamination compared to conventional screening technologies. Moreover, this device does not require bulky robotic liquid handling equipment and is inherently safer given that it is a closed system.

  12. Advanced Mechatronics and MEMS Devices

    CERN Document Server

    2013-01-01

    Advanced Mechatronics and MEMS Devicesdescribes state-of-the-art MEMS devices and introduces the latest technology in electrical and mechanical microsystems. The evolution of design in microfabrication, as well as emerging issues in nanomaterials, micromachining, micromanufacturing and microassembly are all discussed at length in this volume. Advanced Mechatronics also provides a reader with knowledge of MEMS sensors array, MEMS multidimensional accelerometer, artificial skin with imbedded tactile components, as well as other topics in MEMS sensors and transducers. The book also presents a number of topics in advanced robotics and an abundance of applications of MEMS in robotics, like reconfigurable modular snake robots, magnetic MEMS robots for drug delivery and flying robots with adjustable wings, to name a few. This book also: Covers the fundamentals of advanced mechatronics and MEMS devices while also presenting new state-of-the-art methodology and technology used in the application of these devices Prese...

  13. Signal processing devices and networks

    Science.gov (United States)

    Graveline, S. W.

    1985-02-01

    According to an axiom employed with respect to electronic warfare (EW) behavior, system effectiveness increases directly with the amount of information recovered from an intercepted signal. The evolution in EW signal processing capability has proceeded accordingly. After an initiation of EW systems as broadband receivers, the most significant advance was related to the development of digital instantaneous frequency measurement (DIFM) devices. The use of such devices provides significant improvements regarding signal identification and RF measurement to within a few MHz. An even more accurate processing device, the digital RF memory (DRFM), allows frequency characterization to within a few Hz. This invention was made in response to the need to process coherent pulse signals. Attention is given to the generic EW system, the modern EW system, and the generic receiver function for a modern EW system showing typical output signals.

  14. Semiconductor-based, large-area, flexible, electronic devices

    Science.gov (United States)

    Goyal, Amit [Knoxville, TN

    2011-03-15

    Novel articles and methods to fabricate the same resulting in flexible, large-area, triaxially textured, single-crystal or single-crystal-like, semiconductor-based, electronic devices are disclosed. Potential applications of resulting articles are in areas of photovoltaic devices, flat-panel displays, thermophotovoltaic devices, ferroelectric devices, light emitting diode devices, computer hard disc drive devices, magnetoresistance based devices, photoluminescence based devices, non-volatile memory devices, dielectric devices, thermoelectric devices and quantum dot laser devices.

  15. Bragg grating filters in plasmonic V-groove waveguides

    DEFF Research Database (Denmark)

    Smith, Cameron; Desiatov, Boris; Goykhmann, Ilya

    2012-01-01

    We demonstrate spectral filtering via Bragg gratings in plasmonic V-groove waveguides. Transmission spectra of wafer-scale fabricated devices exhibit 8.2 dB extinction ratio with 39.9 nm bandwidth. Near-field measurements verify spectral rejection.......We demonstrate spectral filtering via Bragg gratings in plasmonic V-groove waveguides. Transmission spectra of wafer-scale fabricated devices exhibit 8.2 dB extinction ratio with 39.9 nm bandwidth. Near-field measurements verify spectral rejection....

  16. Modeling floating body memory devices

    Science.gov (United States)

    Hindupur, Ramya

    TCAD simulations have been performed using SILVACO ATLAS 2D device simulator for a Zero-Capacitor Random Access Memory (ZRAM), a new generation memory cell which is being researched as an alternative for DRAM memory cells in order to get rid of the bulky storage capacitor. In our study we have taken into consideration a Dual Gate-ZRAM (DGZRAM) as it helps reduce drain-induced barrier lowering and hence leakage, while having better control of the charge in the substrate. The states are written into the device using impact ionization to generate a large number of holes in the substrate, which alter the threshold voltage of the device. The effect of the gate oxide thickness and substrate body thickness are being taken into consideration to increase the change in the threshold voltage and thereby the noise margin. A DGZRAM structure with a Quantum well introduced into the substrate via a SiGe layer was also simulated. The quantum well introduces a hole storage pocket in the substrate. Comparisons in terms of noise margin have been made for both the devices, which show that the structure with the quantum well in the substrate performs better than the bulk structure. Simulations have been performed taking into consideration gate electrodes with different work functions and it has been observed that while n-polysilicon has a detrimental impact in conventional MOSFETs due to high off-state leakage current, it can be used to obtain low power memory cells. Parameters such as the quantum well doping density, composition of Ge in the quantum well, channel length of the device, SiGe layer thickness and its position with respect to the top gate have been varied to obtain the optimum noise margin for the device.

  17. IMAPS Device Packaging Conference 2017 - Engineered Micro Systems & Devices Track

    Science.gov (United States)

    Varnavas, Kosta

    2017-01-01

    NASA field center Marshall Space Flight Center (Huntsville, AL), has invested in advanced wireless sensor technology development. Developments for a wireless microcontroller back-end were primarily focused on the commercial Synapse Wireless family of devices. These devices have many useful features for NASA applications, good characteristics and the ability to be programmed Over-The-Air (OTA). The effort has focused on two widely used sensor types, mechanical strain gauges and thermal sensors. Mechanical strain gauges are used extensively in NASA structural testing and even on vehicle instrumentation systems. Additionally, thermal monitoring with many types of sensors is extensively used. These thermal sensors include thermocouples of all types, resistive temperature devices (RTDs), diodes and other thermal sensor types. The wireless thermal board will accommodate all of these types of sensor inputs to an analog front end. The analog front end on each of the sensors interfaces to the Synapse wireless microcontroller, based on the Atmel Atmega128 device. Once the analog sensor output data is digitized by the onboard analog to digital converter (A/D), the data is available for analysis, computation or transmission. Various hardware features allow custom embedded software to manage battery power to enhance battery life. This technology development fits nicely into using numerous additional sensor front ends, including some of the low-cost printed circuit board capacitive moisture content sensors currently being developed at Auburn University.

  18. Electronic device and method of manufacturing an electronic device

    NARCIS (Netherlands)

    Roozeboom, F.; Lifka, H.; Vanhelmont, F.; Dekkers, W.

    2014-01-01

    An electronic device comprising at least one die stack having at least a first die (D1) comprising a first array of light emitting units (OLED) for emitting light, a second layer (D2) comprising a second array of via holes (VH) and a third die (D3) comprising a third array of light detecting units

  19. Electronic device and method of manufacturing an electronic device

    NARCIS (Netherlands)

    Roozeboom, F.; Lifka, H.; Vanhelmont, F.; Dekkers, W.

    2013-01-01

    An electronic device comprising at least one die stack having at least a first die (D1) comprising a first array of light emitting units (OLED) for emitting light, a second layer (D2) comprising a second array of via holes (VH) and a third die (D3) comprising a third array of light detecting units

  20. Medical devices and human engineering

    CERN Document Server

    Bronzino, Joseph D

    2014-01-01

    Known as the bible of biomedical engineering, The Biomedical Engineering Handbook, Fourth Edition, sets the standard against which all other references of this nature are measured. As such, it has served as a major resource for both skilled professionals and novices to biomedical engineering.Medical Devices and Human Engineering, the second volume of the handbook, presents material from respected scientists with diverse backgrounds in biomedical sensors, medical instrumentation and devices, human performance engineering, rehabilitation engineering, and clinical engineering.More than three doze

  1. Gas sensing with acoustic devices

    Energy Technology Data Exchange (ETDEWEB)

    Martin, S.J.; Frye, G.C. [Sandia National Labs., Albuquerque, NM (United States); Spates, J.J. [Ktech Corp., Albuquerque, NM (United States); Butler, M.A. [Sandia National Labs., Albuquerque, NM (United States)

    1996-12-31

    A survey is made of acoustic devices that are suitable as gas and vapor sensors. This survey focuses on attributes such as operating frequency, mass sensitivity, quality factor (Q), and their ability to be fabricated on a semiconductor substrate to allow integration with electronic circuitry. The treatment of the device surface with chemically-sensitive films to detect species of interest is discussed. Strategies for improving discrimination are described, including sensor arrays and species concentration and separation schemes. The advantages and disadvantages of integrating sensors with microelectronics are considered, along with the effect on sensitivity of scaling acoustic gas sensors to smaller size.

  2. Metamaterials for terahertz polarimetric devices

    Energy Technology Data Exchange (ETDEWEB)

    O' hara, John F [Los Alamos National Laboratory; Taylor, Antoinette J [Los Alamos National Laboratory; Smirnova, Evgenya [Los Alamos National Laboratory; Azad, Abul [Los Alamos National Laboratory; Chen, Hou-tong [Los Alamos National Laboratory; Peralta, Xomalin G [SNL; Brener, Igal [SNL

    2008-01-01

    We present experimental and numerical investigations of planar terahertz metamaterial structures designed to interact with the state of polarization. The dependence of metamaterial resonances on polarization results in unique amplitude and phase characteristics of the terahertz transmission, providing the basis for polarimetric terahertz devices. We highlight some potential applications for polarimetric devices and present simulations of a terahertz quarter-wave plate and a polarizing terahertz beam splitter. Although this work was performed at tcrahertz frequencies, it may find applications in other frequency ranges as well.

  3. Metamaterials for terahertz polarimetric devices

    Energy Technology Data Exchange (ETDEWEB)

    O' hara, John F [Los Alamos National Laboratory; Taylor, Antoinette J [Los Alamos National Laboratory; Smirnova, Evgenya [Los Alamos National Laboratory; Azad, Abul [Los Alamos National Laboratory

    2008-01-01

    We present experimental and numerical investigations of planar terahertz metamaterial structures designed to interact with the state of polarization. The dependence of metamaterial resonances on polarization results in unique amplitude and phase characteristics of the terahertz transmission, providing the basis for polarimetric terahertz devices. We highlight some potential applications for polarimetric devices and present simulations of a terahertz quarter-wave plate and a polarizing terahertz beam splitter. Although this work was performed at terahertz frequencies, it may find applications in other frequency ranges as well.

  4. Price transparency for medical devices.

    Science.gov (United States)

    Pauly, Mark V; Burns, Lawton R

    2008-01-01

    Hospital buyers of medical devices contract with manufacturers with market power that sell differentiated products. The medical staff strongly influences hospitals' choice of devices. Sellers have sought to limit disclosure of transaction prices. Policy-makers have proposed legislation mandating disclosure, in the interest of greater transparency. We discuss why a manufacturer might charge different prices to different hospitals, the role that secrecy plays, and the consequences of secrecy versus disclosure. We argue that hospital-physician relationships are key to understanding what manufacturers gain from price discrimination. Price disclosure can catalyze a restructuring of those relationships, which, in turn, can improve hospital bargaining.

  5. Computer Independent Data Transfer Device

    OpenAIRE

    Darshana Rarath; Mayank Sharma; Akshay Mane; Pooja Dabral; Roshani Ade

    2017-01-01

    In today’s era, transferring data among distinct storage devices has become one of the tasks which are done most frequently. In order to make data and information omnipresent, it needs to be shared anywhere and anytime. However the reliance of user on a PC or laptop for the same is not efficient. This paper is about the innovative way to overcome this restriction. This paper discusses the development of a portable device with the use of wired and wireless communication applications to share d...

  6. Graphene-based energy devices

    CERN Document Server

    Yusoff, A Rashid bin Mohd

    2015-01-01

    This first book dedicated to the topic provides an up-to-date account of the many opportunities graphene offers for robust, workable energy generation and storage devices. Following a brief overview of the fundamentals of graphene, including the main synthesis techniques, characterization methods and properties, the first part goes on to deal with graphene for energy storage applications, such as lithium-ion batteries, supercapacitors and hydrogen storage. The second part is concerned with graphene-based energy-generation devices, in particular conventional as well as microbial and enzymatic f

  7. Sample processing device and method

    DEFF Research Database (Denmark)

    2011-01-01

    A sample processing device is disclosed, which sample processing device comprises a first substrate and a second substrate, where the first substrate has a first surface comprising two area types, a first area type with a first contact angle with water and a second area type with a second contact...... a sample liquid comprising the sample and the first preparation system is adapted to receive a receiving liquid. In a particular embodiment, a magnetic sample transport component, such as a permanent magnet or an electromagnet, is arranged to move magnetic beads in between the first and second substrates....

  8. A Trusted Portable Computing Device

    Science.gov (United States)

    Ming-wei, Fang; Jun-jun, Wu; Peng-fei, Yu; Xin-fang, Zhang

    A trusted portable computing device and its security mechanism were presented to solve the security issues, such as the attack of virus and Trojan horse, the lost and stolen of storage device, in mobile office. It used smart card to build a trusted portable security base, virtualization to create a secure virtual execution environment, two-factor authentication mechanism to identify legitimate users, and dynamic encryption to protect data privacy. The security environment described in this paper is characteristic of portability, security and reliability. It can meet the security requirement of mobile office.

  9. Documentation of Appliances & Interaction Devices

    DEFF Research Database (Denmark)

    2004-01-01

    The interaction devices and appliances explored in the WorkSPACE project, address spatial computing in the context of work. We have developed and explored a range of appliances and interaction devices. The scope has been to develop tools for support of collaboration by mixing digital and physical...... materials and environments. This has been done by the use of existing hardware technologies in novel combinations, controlled and mediated in the software applications we have developed. These developments, (the SpacePanel, the TagTable and ProjecTable , the SitePack and the software application Topos...

  10. Speech Recognition on Mobile Devices

    DEFF Research Database (Denmark)

    Tan, Zheng-Hua; Lindberg, Børge

    2010-01-01

    The enthusiasm of deploying automatic speech recognition (ASR) on mobile devices is driven both by remarkable advances in ASR technology and by the demand for efficient user interfaces on such devices as mobile phones and personal digital assistants (PDAs). This chapter presents an overview of ASR...... in the mobile context covering motivations, challenges, fundamental techniques and applications. Three ASR architectures are introduced: embedded speech recognition, distributed speech recognition and network speech recognition. Their pros and cons and implementation issues are discussed. Applications within...... command and control, text entry and search are presented with an emphasis on mobile text entry....

  11. Methods of making microfluidic devices

    KAUST Repository

    Buttner, Ulrich

    2017-06-01

    Microfluidics has advanced in terms of designs and structures, however, fabrication methods are either time consuming or expensive to produce, in terms of the facilities and equipment needed. A fast and economically viable method is provided to allow, for example, research groups to have access to microfluidic fabrication. Unlike most fabrication methods, a method is provided to fabricate a microfluidic device in one step. In an embodiment, a resolution of 50 micrometers was achieved by using maskless high-resolution digital light projection (MDLP). Bonding and channel fabrication of complex or simple structures can be rapidly incorporated to fabricate the microfluidic devices.

  12. Electronic Payments using Mobile Communication Devices

    NARCIS (Netherlands)

    Waaij, B.D. van der; Siljee, B.I.J.; Broekhuijsen, B.J.; Ponsioen, C.; Maas, A.; Aten, R.M.; Hoepman, J.H.; Loon, J.H. van; Smit, M.

    2009-01-01

    A method of making a payment uses a first mobile communication device (1) and a second mobile communication device (2), each mobile communication device being provided with a respective near field communication unit (11, 21) and at least one of the mobile communication devices being provided with an

  13. 47 CFR 15.103 - Exempted devices.

    Science.gov (United States)

    2010-10-01

    ... facility. (c) A digital device used exclusively as industrial, commercial, or medical test equipment. (d) A... conditioner (central or window), etc. (e) Specialized medical digital devices (generally used at the direction... or a health care facility. Non-specialized medical devices, i.e., devices marketed through retail...

  14. 77 FR 72924 - Taxable Medical Devices

    Science.gov (United States)

    2012-12-07

    ...: These regulations are applicable to sales of taxable medical devices after December 31, 2012. FOR... The proposed regulations provide that for purposes of the medical device excise tax, a device defined... requested that the final regulations narrow the definition of a taxable medical device so that the excise...

  15. [Electronic Device for Retinal and Iris Imaging].

    Science.gov (United States)

    Drahanský, M; Kolář, R; Mňuk, T

    This paper describes design and construction of a new device for automatic capturing of eye retina and iris. This device has two possible ways of utilization - either for biometric purposes (persons recognition on the base of their eye characteristics) or for medical purposes as supporting diagnostic device. eye retina, eye iris, device, acquisition, image.

  16. Home Healthcare Medical Devices: A Checklist

    Science.gov (United States)

    R Please use this checklist to use and maintain your medical device safely and effectively in your home. As a homecare medical device user, you ... home monitoring devices. Home Healthcare Medical Devices: A Checklist For additional government sources and information visit: CDRH ...

  17. 21 CFR 801.109 - Prescription devices.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Prescription devices. 801.109 Section 801.109 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES LABELING Exemptions From Adequate Directions for Use § 801.109 Prescription devices. A device...

  18. Implantable biomedical devices on bioresorbable substrates

    Science.gov (United States)

    Rogers, John A; Kim, Dae-Hyeong; Omenetto, Fiorenzo; Kaplan, David L; Litt, Brian; Viventi, Jonathan; Huang, Yonggang; Amsden, Jason

    2014-03-04

    Provided herein are implantable biomedical devices, methods of administering implantable biomedical devices, methods of making implantable biomedical devices, and methods of using implantable biomedical devices to actuate a target tissue or sense a parameter associated with the target tissue in a biological environment. Each implantable biomedical device comprises a bioresorbable substrate, an electronic device having a plurality of inorganic semiconductor components supported by the bioresorbable substrate, and a barrier layer encapsulating at least a portion of the inorganic semiconductor components. Upon contact with a biological environment the bioresorbable substrate is at least partially resorbed, thereby establishing conformal contact between the implantable biomedical device and the target tissue in the biological environment.

  19. Flexible spintronic devices on Kapton

    DEFF Research Database (Denmark)

    Bedoya-Pinto, Amilcar; Donolato, Marco; Gobbi, Marco

    2014-01-01

    Magnetic tunnel junctions and nano-sized domain-wall conduits have been fabricated on the flexible substrate Kapton. Despite the delicate nature of tunneling barriers and zig-zag shaped nanowires, the devices show an outstanding integrity and robustness upon mechanical bending. High values...

  20. Nanophotonic Devices for Optical Interconnect

    DEFF Research Database (Denmark)

    Van Thourhout, D.; Spuesens, T.; Selvaraja, S.K.

    2010-01-01

    We review recent progress in nanophotonic devices for compact optical interconnect networks. We focus on microdisk-laser-based transmitters and discuss improved design and advanced functionality including all-optical wavelength conversion and flip-flops. Next we discuss the fabrication uniformity...

  1. Connecting device for air ducts

    Energy Technology Data Exchange (ETDEWEB)

    Kippenberger, G.

    1979-11-29

    The connecting device for air ducts described consists of matched coupling elements of great tensile strength in the form of eyes and cords, which are fitted on the front of the air duct sections. There is a sleeve apron on one side which projects into the other section of air duct.

  2. High performance thermoelectric nanocomposite device

    Science.gov (United States)

    Yang, Jihui [Lakeshore, CA; Snyder, Dexter D [Birmingham, MI

    2011-10-25

    A thermoelectric device includes a nanocomposite material with nanowires of at least one thermoelectric material having a predetermined figure of merit, the nanowires being formed in a porous substrate having a low thermal conductivity and having an average pore diameter ranging from about 4 nm to about 300 nm.

  3. Transmyocardial revascularization devices: technology update

    Directory of Open Access Journals (Sweden)

    Kindzelski BA

    2014-12-01

    Full Text Available Bogdan A Kindzelski, Yifu Zhou, Keith A Horvath Cardiothoracic Surgery Research Program, National Heart, Lung and Blood Institute, National Institutes of Health, Bethesda, MD, USA Abstract: Transmyocardial laser revascularization (TMR emerged as treatment modality for patients with diffuse coronary artery disease not amendable to percutaneous or surgical revascularization. The procedure entails the creation of laser channels within ischemic myocardium in an effort to better perfuse these areas. Currently, two laser devices are approved by the US Food and Drug Administration for TMR – holmium:yttrium–aluminum–garnet and CO2. The two devices differ in regard to energy outputs, wavelengths, ability to synchronize with the heart cycle, and laser–tissue interactions. These differences have led to studies showing different efficacies between the two laser devices. Over 50,000 procedures have been performed worldwide using TMR. Improvements in angina stages, quality of life, and perfusion of the myocardium have been demonstrated with TMR. Although several mechanisms for these improvements have been suggested, evidence points to new blood vessel formation, or angiogenesis, within the treated myocardium, as the major contributory factor. TMR has been used as sole therapy and in combination with coronary artery bypass grafting. Clinical studies have demonstrated that TMR is both safe and effective in angina relief long term. The objective of this review is to present the two approved laser devices and evidence for the safety and efficacy of TMR, along with future directions with this technology. Keywords: laser, revascularization, angiogenesis, coronary artery disease

  4. Tailoring strain in microelectronic devices

    NARCIS (Netherlands)

    van Hemert, T.

    2013-01-01

    The central device of this thesis is the transistor. It acts like a faucet, but hen for electric charge. There is a connection that is called the source, just like the water company. And the charge flows into the drain. Finally there is a handle, here called the gate, to control the flow of charge.

  5. Zero-Power Radio Device.

    Energy Technology Data Exchange (ETDEWEB)

    Brocato, Robert W.

    2018-02-01

    This report describes an unpowered radio receiver capable of detecting and responding to weak signals t ransmit ted from comparatively lon g distances . This radio receiver offers key advantages over a short range zero - power radio receiver pre viously described in SAND2004 - 4610, A Zero - Power Radio Receiver . The device described here can be fabricated as an integrated circuit for use in portable wireless devices, as a wake - up circuit, or a s a stand - alone receiver operating in conjunction with identification decoders or other electroni cs. It builds on key sub - components developed at Sandia National L aboratories o ver many years. It uses surface acous tic wave (SAW) filter technology. It uses custom component design to e nable the efficient use of sma ll aperture antennas. This device uses a key component, the pyroelectric demodulator , covered by Sandia owned U.S. Patent 7397301, Pyroelectric Demodulating Detector [1] . This device is also described in Sandia owned U.S. Patent 97266446, Zero Power Receiver [2].

  6. Wavelength conversion devices and techniques

    DEFF Research Database (Denmark)

    Stubkjær, Kristian; Jørgensen, Carsten; Danielsen, Søren Lykke

    1996-01-01

    wavelengths in an easy way and preferably without opto-electronic conversion. Here, we will first briefly look at advantages of employing optical wavelength converters in WDM networks and next review the optical wavelength conversion devices with emphasis on recent developments....

  7. Featured Invention: Laser Scaling Device

    Science.gov (United States)

    Dunn, Carol Anne

    2008-01-01

    In September 2003, NASA signed a nonexclusive license agreement with Armor Forensics, a subsidiary of Armor Holdings, Inc., for the laser scaling device under the Innovative Partnerships Program. Coupled with a measuring program, also developed by NASA, the unit provides crime scene investigators with the ability to shoot photographs at scale without having to physically enter the scene, analyzing details such as bloodspatter patterns and graffiti. This ability keeps the scene's components intact and pristine for the collection of information and evidence. The laser scaling device elegantly solved a pressing problem for NASA's shuttle operations team and also provided industry with a useful tool. For NASA, the laser scaling device is still used to measure divots or damage to the shuttle's external tank and other structures around the launchpad. When the invention also met similar needs within industry, the Innovative Partnerships Program provided information to Armor Forensics for licensing and marketing the laser scaling device. Jeff Kohler, technology transfer agent at Kennedy, added, "We also invited a representative from the FBI's special photography unit to Kennedy to meet with Armor Forensics and the innovator. Eventually the FBI ended up purchasing some units. Armor Forensics is also beginning to receive interest from DoD [Department of Defense] for use in military crime scene investigations overseas."

  8. Photovoltaic device assembly and method

    Energy Technology Data Exchange (ETDEWEB)

    Keenihan, James R.; Langmaid, Joseph A.; Cleereman, Robert J.; Graham, Andrew T.

    2015-09-29

    The present invention is premised upon a connector device and method that can more easily electrically connect a plurality of PV arrays and/or locate these arrays upon a building or structure. It also can optionally provide some additional components (e.g. a bypass diode and/or an indicator means) and can enhance the serviceability of the array.

  9. ICRF heating on helical devices

    Energy Technology Data Exchange (ETDEWEB)

    Rasmussen, D.A.; Lyon, J.F.; Hoffman, D.J.; Murakami, M.; England, A.C.; Wilgen, J.B.; Jaeger, E.F.; Wang, C.; Batchelor, D.B.

    1995-09-01

    Ion cyclotron range of frequency (ICRF) heating is currently in use on CHS and W7-AS and is a major element of the heating planned for steady state helical devices. In helical devices, the lack of a toroidal current eliminates both disruptions and the need for ICRF current drive, simplifying the design of antenna structures as compared to tokamak applications. However the survivability of plasma facing components and steady state cooling issues are directly applicable to tokamak devices. Results from LHD steady state experiments should be available on a time scale to strongly influence the next generation of steady state tokamak experiments. The helical plasma geometry provides challenges not faced with tokamak ICRF heating, including the potential for enhanced fast ion losses, impurity accumulation, limited access for antenna structures, and open magnetic field lines in the plasma edge. The present results and near term plans provide the basis for steady state ICRF heating of larger helical devices. An approach which includes direct electron, mode conversion, ion minority and ion Bernstein wave heating addresses these issues.

  10. ICRF heating on helical devices

    Energy Technology Data Exchange (ETDEWEB)

    Rasmussen, D.A.; Lyon, J.F.; Hoffman, D.J. [and others

    1995-09-01

    Ion cyclotron range of frequency (ICRF) heating is currently in use on CHS and W7AS and is a major element of the heating planned for steady state helical devices. In helical devices, the lack of a toroidal current eliminates both disruptions and the need for ICRF current drive, simplifying the design of antenna structures as compared to tokamak applications. However the survivability of plasma facing components and steady state cooling issues are directly applicable to tokamak devices. Results from LHD steady state experiments should be available on a time scale to strongly influence the next generation of steady state tokamak experiments. The helical plasma geometry provides challenges not faced with tokamak ICRF heating, including the potential for enhanced fast ion losses, impurity accumulation, limited access for antenna structures, and open magnetic field lines in the plasma edge. The present results and near term plans provide the basis for steady state ICRF heating of larger helical devices. An approach which includes direct electron, mode conversion, ion minority and ion Bernstein wave heating addresses these issues.

  11. New Clothing for Handheld Devices

    Science.gov (United States)

    Roman, Harry T.

    2013-01-01

    Clothing is influenced by many factors, trends, and social happenings. Much of what is worn today had utilitarian roots in the past. In the activitiy presented in this article, students will have the opportunity to redesign clothing for new trends, in this case, the explosion of handheld electronic devices.

  12. Benchmarking Internet of Things devices

    CSIR Research Space (South Africa)

    Kruger, CP

    2014-07-01

    Full Text Available The use of commercial off-the-shelf components for implementing Internet of Things devices has become a common practice amongst researchers and solution providers. IOT solutions, based on the Raspberry Pi, BeagleBone and BeagleBone Black, offer cost...

  13. Diphenylpolyynes For Nonlinear Optical Devices

    Science.gov (United States)

    Stiegman, Albert E.; Perry, Joseph W.; Coulter, Daniel R.

    1989-01-01

    Several diphenylpolyyne compounds found to exhibit second-order nonlinear electric susceptibilities and chemical structures conducive to orientation in appropriate chemical environments. These features make new materials suitable for use in optical devices. Diphenylacetylene links give molecules rodlike characteristics making them amenable to orientation by suspension in liquid crystals. New molecules also have inherent liquid-crystalline properties enabling them to be oriented directly.

  14. Automatic agar tray inoculation device

    Science.gov (United States)

    Wilkins, J. R.; Mills, S. M.

    1972-01-01

    Automatic agar tray inoculation device is simple in design and foolproof in operation. It employs either conventional inoculating loop or cotton swab for uniform inoculation of agar media, and it allows technician to carry on with other activities while tray is being inoculated.

  15. Separating Device for solid Particles

    NARCIS (Netherlands)

    De Jong, T.P.R.; Kattentidt, H.U.R.; Schokker, E.A.

    2001-01-01

    The invention relates to a separating device for solid fragments, comprising a conveyor belt for supplying the fragments, at least one sensor for detecting the fragments, and an ejector for dislodging the fragments from the belt. The ejector is embodied as mechanical impulse-transmitting organ

  16. Mobile Devices in the Classroom

    Science.gov (United States)

    Schachter, Ron

    2009-01-01

    As cell phones--with ever-expanding possibilities of texting, Web browsing, and game playing--have multiplied in recent years among teenagers and even preteens, so have the concerns of teachers and administrators about the distractions these devices can cause. A survey of students and parents earlier this year by the group Common Sense Media found…

  17. Fabrication of Optical Fiber Devices

    Science.gov (United States)

    Andres, Miguel V.

    In this paper we present the main research activities of the Laboratorio de Fibras Opticas del Instituto de Ciencia de los Materiales de la Universidad de Valencia. We show some of the main results obtained for devices based on tapered fibers, fiber Bragg gratings, acousto-optic effects and photonic crystal fibers.

  18. Fiber optic tracheal detection device

    Science.gov (United States)

    Souhan, Brian E.; Nawn, Corinne D.; Shmel, Richard; Watts, Krista L.; Ingold, Kirk A.

    2017-02-01

    Poorly performed airway management procedures can lead to a wide variety of adverse events, such as laryngeal trauma, stenosis, cardiac arrest, hypoxemia, or death as in the case of failed airway management or intubation of the esophagus. Current methods for confirming tracheal placement, such as auscultation, direct visualization or capnography, may be subjective, compromised due to clinical presentation or require additional specialized equipment that is not always readily available during the procedure. Consequently, there exists a need for a non-visual detection mechanism for confirming successful airway placement that can give the provider rapid feedback during the procedure. Based upon our previously presented work characterizing the reflectance spectra of tracheal and esophageal tissue, we developed a fiber-optic prototype to detect the unique spectral characteristics of tracheal tissue. Device performance was tested by its ability to differentiate ex vivo samples of tracheal and esophageal tissue. Pig tissue samples were tested with the larynx, trachea and esophagus intact as well as excised and mounted on cork. The device positively detected tracheal tissue 18 out of 19 trials and 1 false positive out of 19 esophageal trials. Our proof of concept device shows great promise as a potential mechanism for rapid user feedback during airway management procedures to confirm tracheal placement. Ongoing studies will investigate device optimizations of the probe for more refined sensing and in vivo testing.

  19. Magnification devices for endodontic therapy.

    Science.gov (United States)

    Del Fabbro, Massimo; Taschieri, Silvio; Lodi, Giovanni; Banfi, Giuseppe; Weinstein, Roberto L

    2015-12-09

    After the introduction of microsurgical principles in endodontics involving new techniques for root canal treatment, there has been a drive to enhance the visualisation of the surgical field. It is important to know if the technical advantages for the operator brought in by magnification devices such as surgical microscopes, endoscopes and magnifying loupes, are also associated with advantages for the patient in terms of improvement of clinical and radiographic outcomes. This version updates the review published in 2009. To evaluate and compare the effects of endodontic treatment performed with the aid of magnification devices versus endodontic treatment without magnification devices. We also aimed to compare the different magnification devices used in endodontics with one another. The following electronic databases were searched: the Cochrane Oral Health Group Trials Register (to 13 October 2015), the Cochrane Central Register of Controlled Trials (CENTRAL) (The Cochrane Library, 2015, Issue 9), MEDLINE via OVID (1946 to 13 October 2015) and EMBASE via OVID (1980 to 13 October 2015). We searched the US National Institutes of Health Trials Register (http://clinicaltrials.gov) and the WHO Clinical Trials Registry Platform for ongoing trials. No restrictions were placed on the language or date of publication when searching the electronic databases. We considered all randomised controlled trials (RCTs) and quasi-randomised controlled trials comparing endodontic therapy performed with versus without one or more magnification devices, as well as randomised and quasi-randomised trials comparing two or more magnification devices used as an adjunct to endodontic therapy. We conducted screening of search results independently and in duplicate. We obtained full papers for potentially relevant trials. The Cochrane Collaboration statistical guidelines were to be followed for data synthesis. No trials met the inclusion criteria for this review. No article was identified in the

  20. Approaches to improve the Voc of CDTE devices: Device modeling and thinner devices, alternative back contacts

    Science.gov (United States)

    Walkons, Curtis J.

    An existing commercial process to develop thin film CdTe superstrate cells with a lifetime tau=1-3 ns results in Voc= 810-850 mV which is 350 mV lower than expected for CdTe with a bandgap EG = 1.5 eV. Voc is limited by 1.) SRH recombination in the space charge region; and 2.) the Cu2Te back contact to CdTe, which, assuming a 0.3 eV CdTe/Cu2Te barrier, exhibits a work function of phi Cu2Te= 5.5 eV compared to the CdTe valence band of Ev,CdTe=5.8 eV. Proposed solutions to develop CdTe devices with increased Voc are: 1.) reduce SRH recombination by thinning the CdTe layer to ≤ 1 mum; and 2.) develop an ohmic contact back contact using a material with phi BC≥5.8 eV. This is consistent with simulations using 1DSCAPS modeling of CdTe/CdS superstrate cells under AM 1.5 conditions. Two types of CdTe devices are presented. The first type of CdTe device utilizes a window/CdTe stack device with an initial 3-9 mum CdTe layer which is then chemically thinned resulting in regions of the CdTe film with thickness less than 1 mum. The CdTe surface was contacted with a liquid junction quinhydrone-Pt (QH-Pt) probe which enables rapid repeatable Voc measurements on CdTe before and after thinning. In four separate experiments, the window/CdTe stack devices with thinned CdTe exhibited a Voc increase of 30-170 mV, which if implemented using a solid state contact could cut the Voc deficit in half. The second type of CdTe device utilizes C61 PCBM as a back contact to the CdTe, selected since PCBM has a valence band maximum energy (VBM) of 5.8 eV. The PCBM films were grown by two different chemistries and the characterization of the film properties and device results are discussed. The device results show that PCBM exhibits a blocking contact with a 0.6 eV Schottky barrier and possible work function of phiPCBM = 5.2 eV.

  1. Magnification devices for endodontic therapy.

    Science.gov (United States)

    Del Fabbro, Massimo; Taschieri, Silvio; Lodi, Giovanni; Banfi, Giuseppe; Weinstein, Roberto L

    2009-07-08

    After the introduction of microsurgical principles in endodontics, involving new techniques for root canal treatment, there has been a continuous search for enhancing the visualisation of the surgical field. It would be interesting to know if the technical advantages for the operator brought in by magnification devices like surgical microscope, endoscope and magnifying loupes, are also associated with advantages for the patient, in terms of improvement of clinical and radiographic outcomes. The purpose of this systematic review was to evaluate and compare the effects of endodontic treatment performed with the aid of magnification devices versus endodontic treatment without magnification devices. We also aimed at comparing among them the different magnification devices used in endodontics (microscope, endoscope, magnifying loupes). The Cochrane Oral Health Group Trials Register, CENTRAL, MEDLINE and EMBASE were searched with appropriate search strategies. Handsearching included nine dental journals. The bibliographies of relevant clinical trials and relevant articles were checked for identifying studies outside the handsearched journals. Seven manufacturers of instruments in the field of endodontics and/or endodontic surgery, as well as the authors of the identified randomised controlled trials (RCTs) were contacted in order to identify unpublished or ongoing RCTs. There were no language restrictions. The last electronic search was conducted on 2nd April 2009, and the last handsearching was undertaken on 31st January 2009. All randomised and quasi-randomised trials comparing endodontic therapy performed with or without using one or more types of magnification device, as well as randomised and quasi-randomised trials comparing two or more magnification devices used as an adjunct to endodontic therapy were considered. Screening of studies and data extraction were conducted independently and in duplicate. The Cochrane Collaboration statistical guidelines were to be

  2. Endoluminal occlusion devices: technology update

    Directory of Open Access Journals (Sweden)

    Zander T

    2014-12-01

    Full Text Available Tobias Zander,1 Samantha Medina,1 Guillermo Montes,1 Lourdes Nuñez-Atahualpa,1 Michel Valdes,1 Manuel Maynar1,2 1Endoluminal/Vascular Department, Hospiten Hospital Group, Santa Cruz de Tenerife, 2University of Las Palmas de Gran Canarias, Las Palmas, Canary Island, Spain Abstract: Endoluminal occlusion has been performed since the early beginning of interventional radiology. Over recent decades, major technological advances have improved the techniques used and different devices have been developed for changing conditions. Most of these occlusion devices have been implemented in the vascular territory. Early embolization materials included glass particles, hot contrast, paraffin, fibrin, and tissue fragments such as muscle fibers and blood clots; today, occlusion materials include metallic devices, particles, and liquid materials, which can be indicated for proximal or distal occlusion, high-flow and low-flow situations, and in large-caliber and small-caliber vessels, based on need. Technological progress has led to a decreased size of delivery catheters, and an increase in safety due to release systems that permit the withdrawing and replacement of embolization material. Furthermore, bioactive embolization materials have been developed to increase the efficacy of embolization or the biological effect of medication. Finally, materials have been modified for changing indications. Intravascular stents were initially developed to keep an artery open; however, by adding a covering membrane, these stents can be used to occlude the wall of a vessel or other endoluminal structures. This article gives an overview of the devices most utilized for occlusion of endoluminal structures, as well as their major purpose in the endovascular territory. Keywords: embolization, endovascular treatment, occlusion devices, hemorrhage, aneurysm, fistula

  3. Multi-Device to Multi-Device (MD2MD Content-Centric Networking Based on Multi-RAT Device

    Directory of Open Access Journals (Sweden)

    Cheolhoon Kim

    2017-11-01

    Full Text Available This paper proposes a method whereby a device can transmit and receive information using a beacon, and also describes application scenarios for the proposed method. In a multi-device to multi-device (MD2MD content-centric networking (CCN environment, the main issue involves searching for and connecting to nearby devices. However, if a device can’t find another device that satisfies its requirements, the connection is delayed due to the repetition of processes. It is possible to rapidly connect to a device without repetition through the selection of the optimal device using the proposed method. Consequently, the proposed method and scenarios are advantageous in that they enable efficient content identification and delivery in a content-centric Internet of Things (IoT environment, in which multiple mobile devices coexist.

  4. 47 CFR 15.115 - TV interface devices, including cable system terminal devices.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 1 2010-10-01 2010-10-01 false TV interface devices, including cable system... FREQUENCY DEVICES Unintentional Radiators § 15.115 TV interface devices, including cable system terminal devices. (a) Measurements of the radiated emissions of a TV interface device shall be conducted with the...

  5. 76 FR 36993 - Medical Devices; Neurological Devices; Clarification of Classification for Human Dura Mater...

    Science.gov (United States)

    2011-06-24

    ... Drug Administration (FDA) is amending the device regulations to clarify the applicability of the device... of the final rule, human dura mater was regulated as a medical device under Sec. 882.5975. As stated... CFR Part 882 Medical devices, Neurological devices. Therefore, under the Federal Food, Drug, and...

  6. 78 FR 12785 - Certain Wireless Communication Devices, Portable Music and Data Processing Devices, Computers and...

    Science.gov (United States)

    2013-02-25

    ... COMMISSION Certain Wireless Communication Devices, Portable Music and Data Processing Devices, Computers and... communication devices, portable music and data processing devices, computers and components thereof by reason of... evidence demonstrates that the existence of portable communication devices using ``touch sensitive input...

  7. Performance comparison between photovoltaic and thermoradiative devices

    Science.gov (United States)

    Lin, Chungwei; Wang, Bingnan; Teo, Koon Hoo; Zhang, Zhuomin

    2017-12-01

    Photovoltaic (PV) and thermoradiative (TR) devices are power generators that use the radiative energy transfer between a hot and a cold reservoir. For PV devices, the semiconductor at the cold side (PV cell) generates electric power; for TR devices, the semiconductor at the hot side (TR cell) generates electric power. In this work, we compare the performance of the photovoltaic and thermoradiative devices, with and without the non-radiative processes. Without non-radiative processes, PV devices generally produce larger output powers than TR devices. However, when non-radiative processes become important, the TR can outperform the PV devices. This conclusion applies to both far-field and near-field based devices. A key difference in efficiency between PV and TR devices is pointed out.

  8. Flexible devices: from materials, architectures to applications

    Science.gov (United States)

    Zou, Mingzhi; Ma, Yue; Yuan, Xin; Hu, Yi; Liu, Jie; Jin, Zhong

    2018-01-01

    Flexible devices, such as flexible electronic devices and flexible energy storage devices, have attracted a significant amount of attention in recent years for their potential applications in modern human lives. The development of flexible devices is moving forward rapidly, as the innovation of methods and manufacturing processes has greatly encouraged the research of flexible devices. This review focuses on advanced materials, architecture designs and abundant applications of flexible devices, and discusses the problems and challenges in current situations of flexible devices. We summarize the discovery of novel materials and the design of new architectures for improving the performance of flexible devices. Finally, we introduce the applications of flexible devices as key components in real life. Project supported by the National Key R&D Program of China (Nos. 2017YFA0208200, 2016YFB0700600, 2015CB659300), the National Natural Science Foundation of China (Nos. 21403105, 21573108), and the Fundamental Research Funds for the Central Universities (No. 020514380107).

  9. Hardware device binding and mutual authentication

    Energy Technology Data Exchange (ETDEWEB)

    Hamlet, Jason R; Pierson, Lyndon G

    2014-03-04

    Detection and deterrence of device tampering and subversion by substitution may be achieved by including a cryptographic unit within a computing device for binding multiple hardware devices and mutually authenticating the devices. The cryptographic unit includes a physically unclonable function ("PUF") circuit disposed in or on the hardware device, which generates a binding PUF value. The cryptographic unit uses the binding PUF value during an enrollment phase and subsequent authentication phases. During a subsequent authentication phase, the cryptographic unit uses the binding PUF values of the multiple hardware devices to generate a challenge to send to the other device, and to verify a challenge received from the other device to mutually authenticate the hardware devices.

  10. Cohesive Devices in Learners’ Writing

    Directory of Open Access Journals (Sweden)

    Ratnasari Nugraheni

    2016-12-01

    Full Text Available In ESL context, learners may have less attention to the use of conjunctions. In fact, the use of conjunctions in L2 learners’ writings is crucial since it is one type of cohesive devices. This paper aims to find the cohesive devices of conjunctions used by the learners. Through analyzing eight learners’ essays, the writer found 37 forms and 12 types of conjunctions in the learners’ essays. The most significant form of conjunctions was‘and’, whereas the most significant types of conjunction as ‘addition’. Moreover, the writer also found some inappropriate use of conjunctions, which are grouped into five, namely, unclassified, wrong mechanism, L1 interference, wrong forms of conjunctions, and grammatical error.   DOI: https://doi.org/10.24071/llt.2015.180106

  11. Conduit purging device and method

    Science.gov (United States)

    Wilks, Michael T. (Inventor)

    2011-01-01

    A device for purging gas comprises a conduit assembly defining an interior volume. The conduit assembly comprises a first conduit portion having an open first end and an open second end and a second conduit portion having an open first end and a closed second end. The open second end of the first conduit portion is disposed proximate to the open first end of the second conduit portion to define a weld region. The device further comprises a supply element supplying a gas to the interior volume at a substantially constant rate and a vent element venting the gas from the interior volume at a rate that maintains the gas in the interior volume within a pressure range suitable to hold a weld bead in the weld region in equilibrium during formation of a weld to join the first conduit portion and the second conduit portion.

  12. User Experience of Mobile Devices

    DEFF Research Database (Denmark)

    Raptis, Dimitrios

    This thesis focuses on mobile devices and it specifically investigates the effect of their physical form on two perceived user experience qualities, usability and coolness. With the term mobile devices, I refer to interactive products that users interact with while being on the move....... The thesis consists of four research papers and a statement. The four individual papers provide answers to the two research questions, while the statement acts as a bridge that brings the papers together into a coherent whole. The statement initially discusses what user experience and physical form are...... studies focus on generating enough data to map out a relatively unknown phenomenon, while validation studies confirm cause-effect relationships that have been identified from previous research. The statement continues with a discussion on the implications of my findings to the broader user experience...

  13. Physics of semiconductor laser devices

    Energy Technology Data Exchange (ETDEWEB)

    Thompson, G.H.B.

    1980-01-01

    The physics of the semiconductor laser is studied. The basic phenomena that control the operation of the device are analyzed and described in considerable detail. The treatment has been keyed particularly to fundamental concepts and kept general in order to avoid being overtaken by events. The range of phenomena in a semiconductor laser involves a number of scientific disciplines. To cater for the reader who is not already a specialist in all of these the author has endeavoured, in the chapters on fundamental behaviour, to provide in a readable form the minimum background that is needed to understand the more specialist part of the text. As an introduction a general review is given of the whole range of semiconductor laser devices that now exist, the technology involved in their fabrication, the factors that determine their reliability, and their possible role in integrated systems.

  14. Safety of pulsed electric devices.

    Science.gov (United States)

    Nimunkar, Amit J; Webster, John G

    2009-01-01

    The strength-duration curve for tissue excitation can be modeled by a parallel resistor-capacitor circuit that has a time constant. We tested several short-duration electric generators: five electric fence energizers, the Taser X26 and a high-frequency generator to determine their current-versus-time waveforms. We estimated their safety characteristics using existing IEC and UL standards for electric fence energizers. The current standards are difficult to follow, with cumbersome calculations, and do not explicitly explain the physiological relevance of the calculated parameters. Hence we propose a new standard. The proposed new standard would consist of a physical RC circuit with a certain time constant. The investigator would discharge the device into a passive resistor-capacitor circuit and measure the resulting maximum voltage. If the maximum voltage does not exceed a limit, the device passes the test.

  15. Electro-refractive photonic device

    Energy Technology Data Exchange (ETDEWEB)

    Zortman, William A.; Watts, Michael R.

    2015-06-09

    The various technologies presented herein relate to phase shifting light to facilitate any of light switching, modulation, amplification, etc. Structures are presented where a second layer is juxtaposed between a first layer and a third layer with respective doping facilitating formation of p-n junctions at the interface between the first layer and the second layer, and between the second layer and the third layer. Application of a bias causes a carrier concentration change to occur at the p-n junctions which causes a shift in the effective refractive index per incremental change in an applied bias voltage. The effective refractive index enhancement can occur in both reverse bias and forward bias. The structure can be incorporated into a waveguide, an optical resonator, a vertical junction device, a horizontal junction device, a Mach-Zehnder interferometer, a tuneable optical filter, etc.

  16. Dielectrokinetic chromatography and devices thereof

    Science.gov (United States)

    Chirica, Gabriela S; Fiechtner, Gregory J; Singh, Anup K

    2014-04-22

    Disclosed herein are methods and devices for dielectrokinetic chromatography. As disclosed, the devices comprise microchannels having at least one perturber which produces a non-uniformity in a field spanning the width of the microchannel. The interaction of the field non-uniformity with a perturber produces a secondary flow which competes with a primary flow. By decreasing the size of the perturber the secondary flow becomes significant for particles/analytes in the nanometer-size range. Depending on the nature of a particle/analyte present in the fluid and its interaction with the primary flow and the secondary flow, the analyte may be retained or redirected. The composition of the primary flow can be varied to affect the magnitude of primary and/or secondary flows on the particles/analytes and thereby separate and concentrate it from other particles/analytes.

  17. RFQ device for accelerating particles

    Energy Technology Data Exchange (ETDEWEB)

    Shepard, Kenneth W. (Park Ridge, IL); Delayen, Jean R. (Naperville, IL)

    1995-01-01

    A superconducting radio frequency quadrupole (RFQ) device includes four spaced elongated, linear, tubular rods disposed parallel to a charged particle beam axis, with each rod supported by two spaced tubular posts oriented radially with respect to the beam axis. The rod and post geometry of the device has four-fold rotation symmetry, lowers the frequency of the quadrupole mode below that of the dipole mode, and provides large dipole-quadrupole mode isolation to accommodate a range of mechanical tolerances. The simplicity of the geometry of the structure, which can be formed by joining eight simple T-sections, provides a high degree of mechanical stability, is insensitive to mechanical displacement, and is particularly adapted for fabrication with superconducting materials such as niobium.

  18. RFQ device for accelerating particles

    Science.gov (United States)

    Shepard, K.W.; Delayen, J.R.

    1995-06-06

    A superconducting radio frequency quadrupole (RFQ) device includes four spaced elongated, linear, tubular rods disposed parallel to a charged particle beam axis, with each rod supported by two spaced tubular posts oriented radially with respect to the beam axis. The rod and post geometry of the device has four-fold rotation symmetry, lowers the frequency of the quadrupole mode below that of the dipole mode, and provides large dipole-quadrupole mode isolation to accommodate a range of mechanical tolerances. The simplicity of the geometry of the structure, which can be formed by joining eight simple T-sections, provides a high degree of mechanical stability, is insensitive to mechanical displacement, and is particularly adapted for fabrication with superconducting materials such as niobium. 5 figs.

  19. Low Vision Devices and Training

    Directory of Open Access Journals (Sweden)

    Imran Azam Butt

    2004-01-01

    Full Text Available Vision is the ability to see with a clear perception of detail, colour and contrast, and to distinguish objects visually. Like any other sense, vision tends to deteriorate or diminish naturally with age. In most cases, reduction in visual capability can be corrected with glasses, medicine or surgery. However, if the visual changes occur because of an incurable eye disease, condition or injury, vision loss can be permanent. Many people around the world with permanent visual impairment have some residual vision which can be used with the help of low vision services, materials and devices. This paper describes different options for the enhancement of residual vision including optical and non-optical devices and providing training for the low vision client.

  20. Radiosterilization of disposable medical devices

    Science.gov (United States)

    Pourahmad, R.; Pakravan, R.

    1997-02-01

    The initial contamination and the radiosensitivity of microorganisms isolated from 400 samples of disposable medical devices such as gauzes, eye pads, catguts and chest bottles were determined among which the Bacillus spp. were predominant. For each species the hydrophobicity of spore as measured by BATH method was greater than that of the vegetative form. Hence, it is necessary to reduce Bacillus population in samples using a suitable sterilization process such as ionizing radiation.

  1. Topology Optimization of Nanophotonic Devices

    DEFF Research Database (Denmark)

    Yang, Lirong

    This thesis explores the various aspects of utilizing topology optimization in designing nanophotonic devices. Either frequency-domain or time-domain methods is used in combination with the optimization algorithms, depending on various aims of the designing problems. The frequency-domain methods...... lengthscale and flexible pulse delay are addressed to demonstrate time-domain based topology optimization’s potential in designing complicated photonic structures with specifications on the time characteristics of pulses....

  2. Fusion engineering device design description

    Energy Technology Data Exchange (ETDEWEB)

    Flanagan, C.A.; Steiner, D.; Smith, G.E.

    1981-12-01

    The US Magnetic Fusion Engineering Act of 1980 calls for the operation of a Fusion Engineering Device (FED) by 1990. It is the intent of the Act that the FED, in combination with other testing facilities, will establish the engineering feasibility of magnetic fusion energy. During 1981, the Fusion Engineering Design Center (FEDC), under the guidance of a Technical Management Board (TMB), developed a baseline design for the FED. This design is summarized herein.

  3. Penetration testing using mobile devices

    CSIR Research Space (South Africa)

    Shelembe, S

    2012-10-01

    Full Text Available Slide 3 Previous/traditional methods ? Host-based vulnerability scanning ? Network based vulnerability scanning ? Application scanning ? Web Application Assessment Proxy ? CSIR 2012 Slide 4 Previous/traditional methods ? Advantage: more... Mobile Device Mobile OS Pen-testing application ? How it works Current Android hacking applications: ? WiFi Analyzer ? SpoofApp ? FaceNiff ? Penetrate Pro ? Anti-Android Network Toolkit ? ConnectBot ? Network Discovery ? Wireless Tether...

  4. Optoelectronic adaptive neuro-device

    Science.gov (United States)

    Yonezu, H.; Kanamori, K.; Tsuji, K.; Himeno, T.; Takano, Y.; Pak, K.

    1992-04-01

    The development of a new adaptive neurodevice with a nonvolatile memory function is reported. The adaptive neurodevice is based on EEPROM technology and has additional control electrodes; the synaptic weights are varied during operation depending on target signals. The device can be used for implementing learning algorithms for self-organizing neural networks. It can also be used in hardware implementing learning algorithms without a teacher or in other adaptive circuits where the desired output varies according to reference signals.

  5. Fusion Engineering Device design description

    Energy Technology Data Exchange (ETDEWEB)

    Flanagan, C.A.; Steiner, D.; Smith, G.E.

    1981-12-01

    The US Magnetic Fusion Engineering Act of 1980 calls for the operation of a Fusion Engineering Device (FED) by 1990. It is the intent of the Act that the FED, in combination with other testing facilities, will establish the engineering feasibility of magnetic fusion energy. During 1981, the Fusion Engineering Design Center (FEDC), under the guidance of a Technical Management Board (TMB), developed a baseline design for the FED. This design is summarized herein.

  6. Marketing medical devices in Japan.

    Science.gov (United States)

    Ohashi, J

    1998-01-01

    The control of medical devices in Japan has recently undergone significant changes as the country brings its systems into line with those of the United States and Europe. This article discusses pre-market approval, quality system requirements and post-market surveillance. Many technical issues have been harmonized but language is likely to continue to be a barrier to trade. Details of information services that are available to foreign manufacturers and importers are supplied.

  7. A nanophotonic solar thermophotovoltaic device.

    Science.gov (United States)

    Lenert, Andrej; Bierman, David M; Nam, Youngsuk; Chan, Walker R; Celanović, Ivan; Soljačić, Marin; Wang, Evelyn N

    2014-02-01

    The most common approaches to generating power from sunlight are either photovoltaic, in which sunlight directly excites electron-hole pairs in a semiconductor, or solar-thermal, in which sunlight drives a mechanical heat engine. Photovoltaic power generation is intermittent and typically only exploits a portion of the solar spectrum efficiently, whereas the intrinsic irreversibilities of small heat engines make the solar-thermal approach best suited for utility-scale power plants. There is, therefore, an increasing need for hybrid technologies for solar power generation. By converting sunlight into thermal emission tuned to energies directly above the photovoltaic bandgap using a hot absorber-emitter, solar thermophotovoltaics promise to leverage the benefits of both approaches: high efficiency, by harnessing the entire solar spectrum; scalability and compactness, because of their solid-state nature; and dispatchablility, owing to the ability to store energy using thermal or chemical means. However, efficient collection of sunlight in the absorber and spectral control in the emitter are particularly challenging at high operating temperatures. This drawback has limited previous experimental demonstrations of this approach to conversion efficiencies around or below 1% (refs 9, 10, 11). Here, we report on a full solar thermophotovoltaic device, which, thanks to the nanophotonic properties of the absorber-emitter surface, reaches experimental efficiencies of 3.2%. The device integrates a multiwalled carbon nanotube absorber and a one-dimensional Si/SiO2 photonic-crystal emitter on the same substrate, with the absorber-emitter areas optimized to tune the energy balance of the device. Our device is planar and compact and could become a viable option for high-performance solar thermophotovoltaic energy conversion.

  8. Microfluidic devices for biological applications

    CSIR Research Space (South Africa)

    Potgieter, S

    2010-01-01

    Full Text Available of fluids1. These systems are employed in what is known as “lab-on-chip” devices, where a chip is manufactured to perform a specific chemical reaction or diagnostic test. The chip contains beakers, test tubes, mixers, and particle separators, all.... REFERENCES: 1 G.M. Whitesides (2006) Nature 442:368-373. 2 C.D. Chin, V. Linder, S.K.Sia (2007) Lab Chip 7:41-57. http://www.ecmjournal.org ...

  9. Microfluidic ion-sensing devices.

    Science.gov (United States)

    Johnson, R Daniel; Gavalas, Vasilis G; Daunert, Sylvia; Bachas, Leonidas G

    2008-04-14

    Quantitative determinations of ions in a variety of media have been performed traditionally via one of three approaches: optical instrumental methods (e.g., atomic absorption, and inductively-coupled plasma-optical emission or mass spectrometry), "wet" methods, or ion-selective sensors. Each of the approaches, though, possesses limitations including: power/reagent consumption and lack of portability for instrumental techniques; laborious sample-treatment steps for wet methods; and lack of selectivity and sensitivity with sensors when employed with complex samples. Microfluidic device have emerged as a solution to some of these challenges associated with ion analysis. Such systems can integrate multiple sample handling, calibration, and detection steps ("lab-on-a-chip" concept) into a footprint amenable to portability, while requiring small amounts of sample and power. Furthermore, devices can be constructed for multi-analyte detection, either through multiple parallel fluidic architectures or by using arrays of detection elements. This paper reviews recent progress in the development of total-analysis systems for ionic species. Fabrication techniques and various fluid-handling operations are discussed briefly, followed by a number of more mature strategies for microfluidic ion analysis. A variety of approaches expected to comprise the next generation of devices are also presented.

  10. Microfluidic ion-sensing devices

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, R. Daniel [Department of Chemistry, Murray State University, Murray, KY 42071-3346 (United States)], E-mail: daniel.johnson@murraystate.edu; Gavalas, Vasilis G.; Daunert, Sylvia [Department of Chemistry, University of Kentucky, Lexington, KY 40506-0055 (United States); Bachas, Leonidas G. [Department of Chemistry, University of Kentucky, Lexington, KY 40506-0055 (United States)], E-mail: bachas@uky.edu

    2008-04-14

    Quantitative determinations of ions in a variety of media have been performed traditionally via one of three approaches: optical instrumental methods (e.g., atomic absorption, and inductively-coupled plasma-optical emission or mass spectrometry), 'wet' methods, or ion-selective sensors. Each of the approaches, though, possesses limitations including: power/reagent consumption and lack of portability for instrumental techniques; laborious sample-treatment steps for wet methods; and lack of selectivity and sensitivity with sensors when employed with complex samples. Microfluidic device have emerged as a solution to some of these challenges associated with ion analysis. Such systems can integrate multiple sample handling, calibration, and detection steps ('lab-on-a-chip' concept) into a footprint amenable to portability, while requiring small amounts of sample and power. Furthermore, devices can be constructed for multi-analyte detection, either through multiple parallel fluidic architectures or by using arrays of detection elements. This paper reviews recent progress in the development of total-analysis systems for ionic species. Fabrication techniques and various fluid-handling operations are discussed briefly, followed by a number of more mature strategies for microfluidic ion analysis. A variety of approaches expected to comprise the next generation of devices are also presented.

  11. Mobile biometric device (MBD) technology :

    Energy Technology Data Exchange (ETDEWEB)

    Aldridge, Chris D.

    2013-06-01

    Mobile biometric devices (MBDs) capable of both enrolling individuals in databases and performing identification checks of subjects in the field are seen as an important capability for military, law enforcement, and homeland security operations. The technology is advancing rapidly. The Department of Homeland Security Science and Technology Directorate through an Interagency Agreement with Sandia sponsored a series of pilot projects to obtain information for the first responder law enforcement community on further identification of requirements for mobile biometric device technology. Working with 62 different jurisdictions, including components of the Department of Homeland Security, Sandia delivered a series of reports on user operation of state-of-the-art mobile biometric devices. These reports included feedback information on MBD usage in both operational and exercise scenarios. The findings and conclusions of the project address both the limitations and possibilities of MBD technology to improve operations. Evidence of these possibilities can be found in the adoption of this technology by many agencies today and the cooperation of several law enforcement agencies in both participating in the pilot efforts and sharing of information about their own experiences in efforts undertaken separately.

  12. Ferromagnetic Swimmers - Devices and Applications

    Science.gov (United States)

    Hamilton, Joshua; Petrov, Peter; Winlove, C. Peter; Gilbert, Andrew; Bryan, Matthew; Ogrin, Feodor

    2017-11-01

    Microscopic swimming devices hold promise for radically new applications in lab-on-a-chip and microfluidic technology, diagnostics and drug delivery etc. We propose a new class of autonomous ferromagnetic swimming devices, actuated and controlled solely by an oscillating magnetic field. Experimentally, these devices (3.6 mm) are based on a pair of interacting ferromagnetic particles of different size and different anisotropic properties joined by an elastic link and actuated by an external time-dependent magnetic field. The net motion is generated through a combination of dipolar interparticle gradient forces, time-dependent torque and hydrodynamic coupling. We investigate the dynamic performance of a prototype (3.6 mm) of the ferromagnetic swimmer in fluids of different viscosity as a function of the external field parameters and demonstrate stable propulsion over a wide range of Reynolds numbers. Manipulation of the external magnetic field resulted in robust control over the speed and direction of propulsion. We also demonstrate our ferromagnetic swimmer working as a macroscopic prototype of a microfluidic pump. By physically tethering the swimmer, instead of swimming, the swimmer generates a directional flow of liquid around itself.

  13. Electromagnetic brake/clutch device

    Science.gov (United States)

    Vranish, John M.

    1994-01-01

    An electromagnetic brake/clutch device includes a drive shaft supported by at least one bearing for transmitting torque, a housing, affixed to prevent its rotation, surrounding the drive shaft, and an electromagnetically activated device within the housing to selectively prevent and allow rotation of the drive shaft. The electromagnetically activated device includes a plurality of cammed rollers to prevent counter-clockwise rotation of the drive shaft. The drive shaft includes a circumferential disk and the housing includes a reaction ring for engagement with the plurality of cammed rollers. The plurality of cammed rollers are released from engagement with the circumferential disk and the reaction ring by a plurality of tripping mechanisms within the housing. The tripping action uses the locking force to act as a release force merely by changing the boundary conditions of the roller interface angles. The tripping mechanisms include trippers for disengaging the plurality of cammed rollers and an anvil shaped portion for providing lateral movement of the trippers. The plurality of cammed rollers is preloaded to engagement with the circumferential disk and reaction ring by a spring, and is located with respect to an adjacent tripping mechanism with another spring.

  14. From MEMRISTOR to MEMImpedance device

    Energy Technology Data Exchange (ETDEWEB)

    Wakrim, T. [Univ. Grenoble Alpes, LTM (CEA-LETI/Minatec), 38000 Grenoble (France); Univ. Grenoble Alpes, G2Elab, F-38000 Grenoble (France); Vallée, C., E-mail: christophe.vallee@cea.fr; Gonon, P.; Mannequin, C. [Univ. Grenoble Alpes, LTM (CEA-LETI/Minatec), 38000 Grenoble (France); Sylvestre, A. [Univ. Grenoble Alpes, G2Elab, F-38000 Grenoble (France)

    2016-02-01

    The behavior of the capacitance switching of HfO{sub 2} Resistive non-volatile Memories is investigated in view of realizing a MEMImpedance (MEM-Z) device. In such a Metal Insulator Metal structure, the impedance value can be tuned by the adjustment of both resistance and capacitance values. We observe a strong variation of capacitance from positive to negative values in a single layer Metal Insulator Metal device made of HfO{sub 2} deposited by Atomic Layer Deposition, but unfortunately no memory effect is observed. However, in the case of a two layer structure, a device has been obtained with a memory effect where both resistance and capacitance values can be tuned simultaneously, with a variation of capacitance down to negative values to get an inductive behavior. Negative capacitance values are observed for voltage values near SET voltage. A schematic model based on shaped oxygen vacancy density is proposed to account for this capacitance variation. The oxygen vacancies can be either isolated or connected in the bulk of the oxide.

  15. Devices for SRF material characterization

    Science.gov (United States)

    Goudket, P.; Junginger, T.; Xiao, B. P.

    2017-01-01

    The surface resistance R s of superconducting materials can be obtained by measuring the quality factor of an elliptical cavity excited in a transverse magnetic mode (TM010). The value obtained has however to be taken as averaged over the whole surface. A more convenient way to obtain R s, especially of materials which are not yet technologically ready for cavity production, is to measure small samples instead. These can be easily manufactured at low cost, duplicated and placed in film deposition and surface analytical tools. A commonly used design for a device to measure R s consists of a cylindrical cavity excited in a transverse electric (TE110) mode with the sample under test serving as one replaceable endplate. Such a cavity has two drawbacks. For reasonably small samples the resonant frequency will be larger than frequencies of interest concerning SRF application and it requires a reference sample of known R s. In this article we review several devices which have been designed to overcome these limitations, reaching sub-nΩ resolution in some cases. Some of these devices also comprise a parameter space in frequency and temperature which is inaccessible to standard cavity tests, making them ideal tools to test theoretical surface resistance models.

  16. Microencapsulation and Electrostatic Processing Device

    Science.gov (United States)

    Morrison, Dennis R. (Inventor); Mosier, Benjamin (Inventor); Cassanto, John M. (Inventor)

    2001-01-01

    A microencapsulation and electrostatic processing (MEP) device is provided for forming microcapsules. In one embodiment, the device comprises a chamber having a filter which separates a first region in the chamber from a second region in the chamber. An aqueous solution is introduced into the first region through an inlet port, and a hydrocarbon/ polymer solution is introduced into the second region through another inlet port. The filter acts to stabilize the interface and suppress mixing between the two immiscible solutions as they are being introduced into their respective regions. After the solutions have been introduced and have become quiescent, the interface is gently separated from the filter. At this point, spontaneous formation of microcapsules at the interface may begin to occur, or some fluid motion may be provided to induce microcapsule formation. In any case, the fluid shear force at the interface is limited to less than 100 dynes/sq cm. This low-shear approach to microcapsule formation yields microcapsules with good sphericity and desirable size distribution. The MEP device is also capable of downstream processing of microcapsules, including rinsing, re-suspension in tertiary fluids, electrostatic deposition of ancillary coatings, and free-fluid electrophoretic separation of charged microcapsules.

  17. Metamaterial mirrors in optoelectronic devices

    KAUST Repository

    Esfandyarpour, Majid

    2014-06-22

    The phase reversal that occurs when light is reflected from a metallic mirror produces a standing wave with reduced intensity near the reflective surface. This effect is highly undesirable in optoelectronic devices that use metal films as both electrical contacts and optical mirrors, because it dictates a minimum spacing between the metal and the underlying active semiconductor layers, therefore posing a fundamental limit to the overall thickness of the device. Here, we show that this challenge can be circumvented by using a metamaterial mirror whose reflection phase is tunable from that of a perfect electric mirror († = €) to that of a perfect magnetic mirror († = 0). This tunability in reflection phase can also be exploited to optimize the standing wave profile in planar devices to maximize light-matter interaction. Specifically, we show that light absorption and photocurrent generation in a sub-100 nm active semiconductor layer of a model solar cell can be enhanced by ∼20% over a broad spectral band. © 2014 Macmillan Publishers Limited.

  18. Optical Structural Health Monitoring Device

    Science.gov (United States)

    Buckner, Benjamin D.; Markov, Vladimir; Earthman, James C.

    2010-01-01

    This non-destructive, optical fatigue detection and monitoring system relies on a small and unobtrusive light-scattering sensor that is installed on a component at the beginning of its life in order to periodically scan the component in situ. The method involves using a laser beam to scan the surface of the monitored component. The device scans a laser spot over a metal surface to which it is attached. As the laser beam scans the surface, disruptions in the surface cause increases in scattered light intensity. As the disruptions in the surface grow, they will cause the light to scatter more. Over time, the scattering intensities over the scanned line can be compared to detect changes in the metal surface to find cracks, crack precursors, or corrosion. This periodic monitoring of the surface can be used to indicate the degree of fatigue damage on a component and allow one to predict the remaining life and/or incipient mechanical failure of the monitored component. This wireless, compact device can operate for long periods under its own battery power and could one day use harvested power. The prototype device uses the popular open-source TinyOS operating system on an off-the-shelf Mica2 sensor mote, which allows wireless command and control through dynamically reconfigurable multi-node sensor networks. The small size and long life of this device could make it possible for the nodes to be installed and left in place over the course of years, and with wireless communication, data can be extracted from the nodes by operators without physical access to the devices. While a prototype has been demonstrated at the time of this reporting, further work is required in the system s development to take this technology into the field, especially to improve its power management and ruggedness. It should be possible to reduce the size and sensitivity as well. Establishment of better prognostic methods based on these data is also needed. The increase of surface roughness with

  19. Wireless device connection problems and design solutions

    Science.gov (United States)

    Song, Ji-Won; Norman, Donald; Nam, Tek-Jin; Qin, Shengfeng

    2016-09-01

    Users, especially the non-expert users, commonly experience problems when connecting multiple devices with interoperability. While studies on multiple device connections are mostly concentrated on spontaneous device association techniques with a focus on security aspects, the research on user interaction for device connection is still limited. More research into understanding people is needed for designers to devise usable techniques. This research applies the Research-through-Design method and studies the non-expert users' interactions in establishing wireless connections between devices. The "Learning from Examples" concept is adopted to develop a study focus line by learning from the expert users' interaction with devices. This focus line is then used for guiding researchers to explore the non-expert users' difficulties at each stage of the focus line. Finally, the Research-through-Design approach is used to understand the users' difficulties, gain insights to design problems and suggest usable solutions. When connecting a device, the user is required to manage not only the device's functionality but also the interaction between devices. Based on learning from failures, an important insight is found that the existing design approach to improve single-device interaction issues, such as improvements to graphical user interfaces or computer guidance, cannot help users to handle problems between multiple devices. This study finally proposes a desirable user-device interaction in which images of two devices function together with a system image to provide the user with feedback on the status of the connection, which allows them to infer any required actions.

  20. Complications after cardiac implantable electronic device implantations

    DEFF Research Database (Denmark)

    Kirkfeldt, Rikke Esberg; Johansen, Jens Brock; Nohr, Ellen Aagaard

    2013-01-01

    Complications after cardiac implantable electronic device (CIED) treatment, including permanent pacemakers (PMs), cardiac resynchronization therapy devices with defibrillators (CRT-Ds) or without (CRT-Ps), and implantable cardioverter defibrillators (ICDs), are associated with increased patient...

  1. Making Medical Devices Safer at Home

    Science.gov (United States)

    ... condition and recommend any changes related to your equipment. Report serious events to the device supplier and to FDA's MedWatch . For more advice to consumers, see Home Healthcare Medical Devices: A Checklist and Additional Resources on Home ...

  2. Interaction Weaknesses of Personal Navigation Devices

    NARCIS (Netherlands)

    Hipp, Markus; Schaub, Florian; Kargl, Frank; Weber, M.

    2010-01-01

    Automotive navigation systems, especially portable navigation devices (PNDs), are gaining popularity worldwide. Drivers increasingly rely on these devices to guide them to their destination. Some follow them almost blindly, with devastating consequences if the routing goes wrong. Wrong messages as

  3. Fabrication of integrated metallic MEMS devices

    DEFF Research Database (Denmark)

    Yalcinkaya, Arda Deniz; Ravnkilde, Jan Tue; Hansen, Ole

    2002-01-01

    A simple and complementary metal oxide semiconductor (CMOS) compatible fabrication technique for microelectromechanical (MEMS) devices is presented. The fabrication technology makes use of electroplated metal layers. Among the fabricated devices, high quality factor microresonators...

  4. Development of a Rapid Thermoplastic Impregnation Device

    NARCIS (Netherlands)

    Weustink, A.P.D.

    2007-01-01

    A melt impregnation device for rapid thermoplastic impregnation of fiber bundles has been developed through modeling and experiments. The basic principles behind the thermoplastic impregnation process are investigated and the properties needed for a successful thermoplastic impregnation device are

  5. Protecting and securing networked medical devices.

    Science.gov (United States)

    Riha, Chris

    2004-01-01

    Designing, building, and maintaining a secure environment for medical devices is a critical component in health care technology management. This article will address several avenues to harden a health care information network to provide a secure enclave for medical devices.

  6. RF device forensics using passband filter analysis

    Science.gov (United States)

    King-Smith, Deen; Mikkilineni, Aravind K.; Gelfand, Saul; Delp, Edward J., III

    2009-02-01

    Given the wide use of Radio Frequency (RF) devices for applications ranging from data networks to wireless sensors, it is of interest to be able to characterize individual devices to verify compliance with FCC Part 15 rules. In an effort to characterize these types of devices we have developed a system that utilizes specially designed probe signals to elicit a response from the device from which unique characteristics can be extracted. The features that uniquely characterize a device are referred to as device signatures or device fingerprints. We apply this approach to RF devices which employ different bandpass filters, and construct training based classifiers which are highly accurate. We also introduce a model-based framework for optimal detection that can be employed to obtain performance limits, and to study model mismatch and probe optimization.

  7. Modeling and Simulation of LDMOS Device

    OpenAIRE

    Sunitha HD; Keshaveni N

    2015-01-01

    Laterally Diffused MOSFET (LDMOS) are widely used in modern communication industry and other applications. LDMOS offers various advantages over conventional MOSFETs with little process change. In the present paper, an LDMOS device is modeled and simulated in SILVACO device simulator package using the ATHENA and ATLAS modules. The complete fabrication process is modeled and the device performance is simulated. The modeled device gives a 46 V breakdown voltage for a devi...

  8. Nanostructured energy devices equilibrium concepts and kinetics

    CERN Document Server

    Bisquert, Juan

    2014-01-01

    Due to the pressing needs of society, low cost materials for energy devices have experienced an outstanding development in recent times. In this highly multidisciplinary area, chemistry, material science, physics, and electrochemistry meet to develop new materials and devices that perform required energy conversion and storage processes with high efficiency, adequate capabilities for required applications, and low production cost. Nanostructured Energy Devices: Equilibrium Concepts and Kinetics introduces the main physicochemical principles that govern the operation of energy devices. It inclu

  9. Pragmatic Approach to Device-Independent Color

    Science.gov (United States)

    Brandt, R. D.; Capraro, K. S.

    1995-01-01

    JPL has been producing images of planetary bodies for over 30 years. The results of an effort to implement device-independent color on three types of devices are described. The goal is to produce near the same eye-brain response when the observer views the image produced by each device under the correct lighting conditions. The procedure used to calibrate and obtain each device profile is described.

  10. Medical devices regulations, standards and practices

    CERN Document Server

    Ramakrishna, Seeram; Wang, Charlene

    2015-01-01

    Medical Devices and Regulations: Standards and Practices will shed light on the importance of regulations and standards among all stakeholders, bioengineering designers, biomaterial scientists and researchers to enable development of future medical devices. Based on the authors' practical experience, this book provides a concise, practical guide on key issues and processes in developing new medical devices to meet international regulatory requirements and standards. Provides readers with a global perspective on medical device regulationsConcise and comprehensive information on how to desig

  11. Synaptic electronics: materials, devices and applications.

    Science.gov (United States)

    Kuzum, Duygu; Yu, Shimeng; Wong, H-S Philip

    2013-09-27

    In this paper, the recent progress of synaptic electronics is reviewed. The basics of biological synaptic plasticity and learning are described. The material properties and electrical switching characteristics of a variety of synaptic devices are discussed, with a focus on the use of synaptic devices for neuromorphic or brain-inspired computing. Performance metrics desirable for large-scale implementations of synaptic devices are illustrated. A review of recent work on targeted computing applications with synaptic devices is presented.

  12. Progress and Prospects in Stretchable Electroluminescent Devices

    Directory of Open Access Journals (Sweden)

    Wang Jiangxin

    2017-03-01

    Full Text Available Stretchable electroluminescent (EL devices are a new form of mechanically deformable electronics that are gaining increasing interests and believed to be one of the essential technologies for next generation lighting and display applications. Apart from the simple bending capability in flexible EL devices, the stretchable EL devices are required to withstand larger mechanical deformations and accommodate stretching strain beyond 10%. The excellent mechanical conformability in these devices enables their applications in rigorous mechanical conditions such as flexing, twisting, stretching, and folding.The stretchable EL devices can be conformably wrapped onto arbitrary curvilinear surface and respond seamlessly to the external or internal forces, leading to unprecedented applications that cannot be addressed with conventional technologies. For example, they are in demand for wide applications in biomedical-related devices or sensors and soft interactive display systems, including activating devices for photosensitive drug, imaging apparatus for internal tissues, electronic skins, interactive input and output devices, robotics, and volumetric displays. With increasingly stringent demand on the mechanical requirements, the fabrication of stretchable EL device is encountering many challenges that are difficult to resolve. In this review, recent progresses in the stretchable EL devices are covered with a focus on the approaches that are adopted to tackle materials and process challenges in stretchable EL devices and delineate the strategies in stretchable electronics. We first introduce the emission mechanisms that have been successfully demonstrated on stretchable EL devices. Limitations and advantages of the different mechanisms for stretchable EL devices are also discussed. Representative reports are reviewed based on different structural and material strategies. Unprecedented applications that have been enabled by the stretchable EL devices are

  13. Progress and Prospects in Stretchable Electroluminescent Devices

    Science.gov (United States)

    Wang, Jiangxin; Lee, Pooi See

    2017-03-01

    Stretchable electroluminescent (EL) devices are a new form of mechanically deformable electronics that are gaining increasing interests and believed to be one of the essential technologies for next generation lighting and display applications. Apart from the simple bending capability in flexible EL devices, the stretchable EL devices are required to withstand larger mechanical deformations and accommodate stretching strain beyond 10%. The excellent mechanical conformability in these devices enables their applications in rigorous mechanical conditions such as flexing, twisting, stretching, and folding.The stretchable EL devices can be conformably wrapped onto arbitrary curvilinear surface and respond seamlessly to the external or internal forces, leading to unprecedented applications that cannot be addressed with conventional technologies. For example, they are in demand for wide applications in biomedical-related devices or sensors and soft interactive display systems, including activating devices for photosensitive drug, imaging apparatus for internal tissues, electronic skins, interactive input and output devices, robotics, and volumetric displays. With increasingly stringent demand on the mechanical requirements, the fabrication of stretchable EL device is encountering many challenges that are difficult to resolve. In this review, recent progresses in the stretchable EL devices are covered with a focus on the approaches that are adopted to tackle materials and process challenges in stretchable EL devices and delineate the strategies in stretchable electronics. We first introduce the emission mechanisms that have been successfully demonstrated on stretchable EL devices. Limitations and advantages of the different mechanisms for stretchable EL devices are also discussed. Representative reports are reviewed based on different structural and material strategies. Unprecedented applications that have been enabled by the stretchable EL devices are reviewed. Finally, we

  14. Medical Device Regulation: Time to Improve Performance

    OpenAIRE

    Kramer, Daniel B.; Shuai Xu; Kesselheim, Aaron S.

    2012-01-01

    Editors' Summary Background Medical devices—health technologies that are not medicines, vaccines, or clinical procedures—cover a vast range of equipment from the simple to the more complex. Medical devices are essential for patient care, and in the past decade, new devices have offered improved treatment alternatives for many diseases and conditions, leading to substantial growth in the US$350 billion medical device industry. However, new medical devices also pose substantial risks to patient...

  15. Handbook of materials for medical devices

    National Research Council Canada - National Science Library

    Davis, J. R

    2003-01-01

    ... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . vii Introduction Chapter 1 Overview of Biomaterials and Their Use in Medical Devices . . . . . . . . . . . . . . . . 1 Uses for Biomaterials...

  16. A device for measuring electron beam characteristics

    Directory of Open Access Journals (Sweden)

    M. Andreev

    2017-01-01

    Full Text Available This paper presents a device intended for diagnostics of electron beams and the results obtained with this device. The device comprises a rotating double probe operating in conjunction with an automated probe signal collection and processing system. This provides for measuring and estimating the electron beam characteristics such as radius, current density, power density, convergence angle, and brightness.

  17. 78 FR 18233 - Medical Devices; Technical Amendment

    Science.gov (United States)

    2013-03-26

    ... Administration (FDA) is amending certain medical device regulations to correct minor errors in the Code of... outdated Web site addresses affecting certain regulations regarding medical devices. Publication of this..., 876, 878, 880, 882, 884, 886, 888, 890, and 892 Medical Devices; Technical Amendment AGENCY: Food and...

  18. 75 FR 16351 - Medical Devices; Technical Amendment

    Science.gov (United States)

    2010-04-01

    ..., and 1050 Medical Devices; Technical Amendment AGENCY: Food and Drug Administration, HHS. ACTION: Final... device regulations to correct statutory and regulatory references to ensure accuracy, consistency, and.... 360hh- 360ss). The Safe Medical Devices Act of 1990 (SMDA) (Public Law 101- 629), transferred the...

  19. 78 FR 15878 - Taxable Medical Devices; Correction

    Science.gov (United States)

    2013-03-13

    ... Internal Revenue Service 26 CFR Part 48 RIN 1545-BJ44 Taxable Medical Devices; Correction AGENCY: Internal... certain medical devices, enacted by the Health Care and Education Reconciliation Act of 2010 in...., Example 11., and Example 13. The revisions read as follows: Sec. 48.4191-2 Taxable medical device...

  20. 30 CFR 75.522 - Lighting devices.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Lighting devices. 75.522 Section 75.522 Mineral... SAFETY STANDARDS-UNDERGROUND COAL MINES Electrical Equipment-General § 75.522 Lighting devices. No device for the purpose of lighting any coal mine which has not been approved by the Secretary or his...

  1. Anti-malware software and medical devices.

    Science.gov (United States)

    2010-10-01

    Just as much as healthcare information systems, medical devices need protection against cybersecurity threats. Anti-malware software can help safeguard the devices in your facility-but it has limitations and even risks. Find out what steps you can take to manage anti-malware applications in your devices.

  2. Assistive Devices for Students with Disabilities.

    Science.gov (United States)

    Wisniewski, Lech; Sedlak, Robert

    1992-01-01

    Describes a variety of devices that can assist students with disabilities. Highlights recently developed devices for students with specific learning disabilities, and with vision, hearing, health, physical, and speech and language impairments. The devices can help rehabilitate, reeducate, facilitate normalcy, or augment current functioning. (GLR)

  3. 21 CFR 820.130 - Device packaging.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Device packaging. 820.130 Section 820.130 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES... shall ensure that device packaging and shipping containers are designed and constructed to protect the...

  4. Regulatory Requirements for Devices for the Handicapped.

    Science.gov (United States)

    Stigi, John, Ed.; Rivera, Richard J., Ed.

    This booklet explains in question/answer form the basic regulatory requirements established by the Food and Drug Administration (FDA) of the federal government concerning the manufacture, marketing and distribution of medical devices (including implantable devices and devices previously regulated as drugs) for persons with disabilities. Topics…

  5. Electrochromic devices and related products and methods

    Energy Technology Data Exchange (ETDEWEB)

    Snow, Timothy; McFadden, Judith; Tenent, Robert

    2018-01-30

    An electrochromic device may be switchable between a transparent state and at least one reflective state. A lithium-containing reflective feature may form when the electrochromic device is switched from the transparent state to the reflective state. Various products and methods may involve the electrochromic device.

  6. Electrostatic MEMS devices with high reliability

    Science.gov (United States)

    Goldsmith, Charles L; Auciello, Orlando H; Sumant, Anirudha V; Mancini, Derrick C; Gudeman, Chris; Sampath, Suresh; Carlilse, John A; Carpick, Robert W; Hwang, James

    2015-02-24

    The present invention provides for an electrostatic microelectromechanical (MEMS) device comprising a dielectric layer separating a first conductor and a second conductor. The first conductor is moveable towards the second conductor, when a voltage is applied to the MEMS device. The dielectric layer recovers from dielectric charging failure almost immediately upon removal of the voltage from the MEMS device.

  7. Assessing the Security of Connected Diabetes Devices.

    Science.gov (United States)

    Out, Dirk-Jan; Tettero, Olaf

    2017-03-01

    This article discusses the assessment of the (cyber)security of wirelessly connected diabetes devices under the DTSEC standard. We discuss the relation between diabetes devices and hackers, provide an overview of the DTSEC standard, and describe the process of security assessment of diabetes devices.

  8. Apparatus for assembly of microelectronic devices

    Science.gov (United States)

    Okandan, Murat; Nielson, Gregory N.; Cruz-Campa, Jose Luis; Lavin, Judith Maria; Resnick, Paul J.

    2017-09-12

    An apparatus including a carrier substrate configured to move a microelectronic device. The apparatus further includes a rotatable body configured to receive the microelectronic device. Additionally, the apparatus includes a second substrate configured to receive the microelectronic device from the rotatable body.

  9. Device and method for measuring biomarkers

    NARCIS (Netherlands)

    Wiedemair, Justyna; Olthuis, Wouter; van den Berg, Albert

    2011-01-01

    The invention relates to a device for the measurement of hydrogen peroxide and optionally other biomarkers in a gaseous mixture, and in particular to a microfabricated device. The device comprises hydrogen peroxide capturing means and an electromechanical sensor comprising a sensing element in

  10. Device and method for measuring biomarkers

    NARCIS (Netherlands)

    Wiedemair, Justyna; Olthuis, Wouter; van den Berg, Albert

    2012-01-01

    The invention relates to a device for the measurement of hydrogen peroxide and optionally other biomarkers in a gaseous mixture, and in particular to a microfabricated device. The device comprises hydrogen peroxide capturing means and an electromechanical sensor comprising a sensing element in

  11. Mobile devices tools and technologies

    CERN Document Server

    Collins, Lauren

    2015-01-01

    Mobile Devices: Tools and Technologies provides readers with an understanding of the mobile landscape available to app developers, system and network engineers, and the avid techie. As the trend of mobile technology has enabled the continuous development of ubiquitous applications, this book offers insights into tools and technologies critical to evaluating and implementing mobile strategies.The book is organized into four parts of 18 contributed chapters written by engineers in the areas of application and database development, mobile enterprise strategy, and networking and security. Througho

  12. Inflatable Personal Flotation Device Study.

    Science.gov (United States)

    1981-02-01

    late. t, h Iw . No cood (1) - CVider would not Ipu, tore 1t) - ( I\\ inder d idn ’t punk t n- t . Tried several times. Lost belt in lake, Lr ic - caIIt...dii not respond as expected (1) 6. (C) - When C02 cylinder is used to inflate, all the snaps do not pop open (1) - No event (1) - When inflated it is...Upon inflation, the snap closest to my face popped , striking my hand and face (1) - Device rode up over back of head in rough water (1) - None (1

  13. Fullerene Derived Molecular Electronic Devices

    Science.gov (United States)

    Menon, Madhu; Srivastava, Deepak; Saini, Subbash

    1998-01-01

    The carbon Nanotube junctions have recently emerged as excellent candidates for use as the building blocks in the formation of nanoscale electronic devices. While the simple joint of two dissimilar tubes can be generated by the introduction of a pair of heptagon-pentagon defects in an otherwise perfect hexagonal grapheme sheet, more complex joints require other mechanisms. In this work we explore structural and electronic properties of complex 3-point junctions of carbon nanotubes using a generalized tight-binding molecular-dynamics scheme.

  14. Method of making optoelectric devices

    DEFF Research Database (Denmark)

    2012-01-01

    into a light harvesting polymer that is substantially insoluble in the solvent comprised in the coating ink; (d) forming a hole transport layer on the active layer according to the following method: i) coating the active layer with a solution comprising a hole transporting compound, water and an alcohol......A method of preparing an optoelectric device, comprising: (a) providing a substrate on which is formed a first electrode layer; (b) forming an electron transport layer according to the following method: i) forming a film of a coating ink comprising zinc acetate in aqueous solution; ii) drying...

  15. Silicon Nano-Photonic Devices

    DEFF Research Database (Denmark)

    Pu, Minhao

    to microwave systems and biosensing devices. An ultra-low loss inverse taper coupler for interfacing silicon ridge waveguides and optical bers is introduced and insertion losses of less than 1 dB are achieved for both transverse-electric (TE) and transversemagnetic (TM) polarizations. Integrated...... with the couplers, a silicon ridge waveguide is utilized in nonlinear all-optical signal processing for optical time division multiplexing (OTDM) systems. Record ultra-highspeed error-free optical demultiplexing and waveform sampling are realized and demonstrated for the rst time. Microwave phase shifters and notch...

  16. Fundamentals of liquid crystal devices

    CERN Document Server

    Yang, Deng-Ke

    2014-01-01

    Revised throughout to cover the latest developments in the fast moving area of display technology, this 2nd edition of Fundamentals of Liquid Crystal Devices, will continue to be a valuable resource for those wishing to understand the operation of liquid crystal displays. Significant updates include new material on display components, 3D LCDs and blue-phase displays which is one of the most promising new technologies within the field of displays and it is expected that this new LC-technology will reduce the response time and the number of optical components of LC-modules. Prof. Yang is a pion

  17. Design of microwave active devices

    CERN Document Server

    Gautier , Jean-Luc

    2014-01-01

    This book presents methods for the design of the main microwave active devices. The first chapter focuses on amplifiers working in the linear mode. The authors present the problems surrounding narrowband and wideband impedance matching, stability, polarization and the noise factor, as well as specific topologies such as the distributed amplifier and the differential amplifier. Chapter 2 concerns the power amplifier operation. Specific aspects on efficiency, impedance matching and class of operation are presented, as well as the main methods of linearization and efficiency improvement. Freq

  18. Cavity Solitons in VCSEL Devices

    Directory of Open Access Journals (Sweden)

    S. Barbay

    2011-01-01

    Full Text Available We review advances on the experimental study of cavity solitons in VCSELs in the past decade. We emphasize on the design and fabrication of electrically or optically pumped broad-area VCSELs used for CSs formation and review different experimental configurations. Potential applications of CSs in the field of photonics are discussed, in particular the use of CSs for all-optical processing of information and for VCSELs characterization. Prospects on self-localization studies based on vertical cavity devices involving new physical mechanisms are also given.

  19. Spintronics from materials to devices

    CERN Document Server

    Felser, Claudia

    2013-01-01

    Spintronics is an emerging technology exploiting the spin degree of freedom and has proved to be very promising for new types of fast electronic devices. Amongst the anticipated advantages of spintronics technologies, researchers have identified the non-volatile storage of data with high density and low energy consumption as particularly relevant. This monograph examines the concept of half-metallic compounds perspectives to obtain novel solutions and discusses several oxides such as perovskites, double perovskites and CrO2 as well as Heusler compounds. Such materials can be designed and made

  20. Process design of microdomains with quantum mechanics for giant pulse lasers.

    Science.gov (United States)

    Sato, Yoichi; Akiyama, Jun; Taira, Takunori

    2017-09-06

    The power scaling of laser devices can contribute to the future of humanity. Giant microphotonics have been advocated as a solution to this issue. Among various technologies in giant microphotonics, process control of microdomains with quantum mechanical calculations is expected to increase the optical power extracted per unit volume in gain media. Design of extensive variables influencing the Gibbs energy of controlled microdomains in materials can realize desired properties. Here we estimate the angular momentum quantum number of rare-earth ions in microdomains. Using this process control, we generate kilowatt-level laser output from orientation-controlled microdomains in a laser gain medium. We also consider the limitations of current samples, and discuss the prospects of power scaling and applications of our technology. This work overturns at least three common viewpoints in current advanced technologies, including material processing based on magnetohydrodynamics, grain-size control of transparent polycrystals in fine ceramics, and the crystallographic symmetry of laser ceramics in photonics.