WorldWideScience

Sample records for volumetric infusion pump

  1. [External lumbar drainage with volumetric continuing infusion pump in patients with cerebrospinal fluid leak. A case series].

    Science.gov (United States)

    Manso Melgosa, Ana Belén; García Gutiérrez, Helena; Fernández Porras, Mónica; Castrillo Manero, Ana Berta; Pérez Marijuán, Belén

    To describe the incidence and complications arising in a number of cases of patients with cerebrospinal fluid leak treated by external lumbar drainage with infusion pump (IP) volumetric continuous from 2001 to 2014. Quantify cerebrospinal fluid leak closed by lumbar drainage with IP. Retrospective descriptive case series study. patients undergoing transsphenoidal pituitary surgery, Chiari surgery and laminectomy, that developed postoperative cerebrospinal fluid leak treated with continuous external lumbar drainage by IP. age, sex, type of intervention, variables related to the practice of the pump and complications. Average and medians were calculated for quantitative variables, frequencies and percentages for qualitative. Sample: 11 subjects. Incidence in running IP: disconnection, occlusion and acoustic alarm activation. Most frequently complication is headache; a case of pneumocephalus. The small number of subjects and the heterogeneity of these do not allow for comparison or establishing associations between variables. The resolution of the cerebrospinal fluid leak with continuous IP is lower in this study than others, and may be influenced by the small number of subjects. It should be noted the frequent activation of the pump alarm for no apparent cause. Protocol would be developed for preparing the IP team to reduce the acoustic alarm activation, and would make a prospective multicenter study. Copyright © 2016 Elsevier España, S.L.U. All rights reserved.

  2. 21 CFR 880.5725 - Infusion pump.

    Science.gov (United States)

    2010-04-01

    ... Infusion pump. (a) Identification. An infusion pump is a device used in a health care facility to pump fluids into a patient in a controlled manner. The device may use a piston pump, a roller pump, or a... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Infusion pump. 880.5725 Section 880.5725 Food and...

  3. Understanding Infusion Pumps.

    Science.gov (United States)

    Mandel, Jeff E

    2018-04-01

    Infusion systems are complicated electromechanical systems that are used to deliver anesthetic drugs with moderate precision. Four types of systems are described-gravity feed, in-line piston, peristaltic, and syringe. These systems are subject to a number of failure modes-occlusion, disconnection, siphoning, infiltration, and air bubbles. The relative advantages of the various systems and some of the monitoring capabilities are discussed. A brief example of the use of an infusion system during anesthetic induction is presented. With understanding of the functioning of these systems, users may develop greater comfort.

  4. Scavenged body heat powered infusion pump

    International Nuclear Information System (INIS)

    Bell, Alexander; Ehringer, William D; McNamara, Shamus

    2013-01-01

    An infusion pump powered by body heat is investigated in this paper, with the goal of addressing the needs of dermal wound healing. The infusion pump incorporates a Knudsen gas pump, a type of thermally driven pump, to pneumatic push the pharmaceutical agent from a reservoir. Two designs are considered: an integrated pump and reservoir, and a design with cascaded pump and reservoir. Thermal models are developed for both pumps, and the simulations agree well with the experimental results. The integrated pump and reservoir design uses hydrophobic materials to prevent a flow from occurring unless the infusion pump is placed on a human body. Flow rates in the µL min −1 range for the integrated pump and reservoir, and approximately 70 µL min −1 for the cascaded pump were obtained. The dynamic behavior of the cascaded pump is described based on the thermal models. Multiple copies of the cascaded pump are easily made in series or parallel, to increase either the pressure or the flow rate. The flow rate of multiple pumps in series does not change, and the pressure of multiple pumps in parallel does not change. (paper)

  5. Comparison of infusion pumps calibration methods

    Science.gov (United States)

    Batista, Elsa; Godinho, Isabel; do Céu Ferreira, Maria; Furtado, Andreia; Lucas, Peter; Silva, Claudia

    2017-12-01

    Nowadays, several types of infusion pump are commonly used for drug delivery, such as syringe pumps and peristaltic pumps. These instruments present different measuring features and capacities according to their use and therapeutic application. In order to ensure the metrological traceability of these flow and volume measuring equipment, it is necessary to use suitable calibration methods and standards. Two different calibration methods can be used to determine the flow error of infusion pumps. One is the gravimetric method, considered as a primary method, commonly used by National Metrology Institutes. The other calibration method, a secondary method, relies on an infusion device analyser (IDA) and is typically used by hospital maintenance offices. The suitability of the IDA calibration method was assessed by testing several infusion instruments at different flow rates using the gravimetric method. In addition, a measurement comparison between Portuguese Accredited Laboratories and hospital maintenance offices was performed under the coordination of the Portuguese Institute for Quality, the National Metrology Institute. The obtained results were directly related to the used calibration method and are presented in this paper. This work has been developed in the framework of the EURAMET projects EMRP MeDD and EMPIR 15SIP03.

  6. 75 FR 21641 - Infusion Pumps; Public Meeting; Request for Comments

    Science.gov (United States)

    2010-04-26

    ...] Infusion Pumps; Public Meeting; Request for Comments AGENCY: Food and Drug Administration, HHS. ACTION... announcing a public meeting regarding external infusion pumps. The purpose of the meeting is to inform the public about current problems associated with external infusion pump use, to help the agency identify...

  7. Effect of insulin pump infusion on comprehensive stress state of ...

    African Journals Online (AJOL)

    Effect of insulin pump infusion on comprehensive stress state of patients with diabetic ketoacidosis. ... Relevant diabetes-associated serum indices, oxidative stress and stress hormone levels were compared between the ... from 32 Countries:.

  8. Low flow measurement for infusion pumps: implementation and uncertainty determination of the normalized method

    International Nuclear Information System (INIS)

    Cebeiro, J; Musacchio, A; Sardá, E Fernández

    2011-01-01

    Intravenous drug delivery is a standard practice in hospitalized patients. As the blood concentration reached depends directly on infusion rate, it is important to use safe devices that guarantee output accuracy. In pediatric intensive care units, low infusion rates (i.e. lower than 10.0 ml/h) are frequently used. Thus, it would be necessary to use control programs to search for deviations at this flow range. We describe the implementation of a gravimetric method to test infusion pumps in low flow delivery. The procedure recommended by the ISO/IEC 60601-2-24 standard was used being a reasonable option among the methods frequently used in hospitals, such as infusion pumps analyzers and volumetric cylinders. The main uncertainty sources affecting this method are revised and a numeric and graphic uncertainty analysis is presented in order to show its dependence on flow. Additionally, the obtained uncertainties are compared to those presented by an automatic flow analyzer. Finally, the results of a series of tests performed on a syringe infusion pump operating at low rates are shown.

  9. [Radiotherapy and implantable medical device: example of infusion pumps].

    Science.gov (United States)

    Abrous-Anane, S; Benhassine, S; Lopez, S; Cristina, K; Mazeron, J-J

    2013-12-01

    Indication for radiotherapy is often questioned for patients equipped with implantable medical devices like infusion pumps as the radiation tolerance is poor or not known. We report here on the case of a patient who we treated with pelvic radiotherapy for cervical cancer and who had an infusion pump in iliac fossa. We conducted a series of tests on five identical pumps that insured that the treatment protocol is harmless to the implanted device. Copyright © 2013 Société française de radiothérapie oncologique (SFRO). Published by Elsevier SAS. All rights reserved.

  10. Quantitative assessment of haemolysis secondary to modern infusion pumps.

    Science.gov (United States)

    Poder, T G; Boileau, J-C; Lafrenière, R; Thibault, L; Carrier, N; de Grandmont, M-J; Beauregard, P

    2017-04-01

    Although most studies have shown that little haemolysis is induced by infusion pumps, there are some notable exceptions. Only limited data are available on the actual infusion pumps that are most used in hospitals in Quebec and elsewhere, namely, the Infusomat ® Space (peristaltic), Plum A+™ (piston) and Colleague ® CXE (shuttle) pumps. Haemolysis and potassium levels were compared before and after the use of the three different infusion pumps. Using 135 units of packed red blood cells (RBCs) aged from 10 to 28 days, 27 measurements were taken for each pump at various flow rates (30, 60, 150, 300 and 450 ml/h) and were compared with measurements taken before using the pumps. The range of flow rates was chosen to cover those of paediatric and adult transfusions. The shuttle- and piston-type pumps resulted in low haemolysis levels. The peristaltic-type pump produced significantly more haemolysis, which worsened at low flow rates, but the absolute value of haemolysis remained within the range recommended by the regulatory agencies in North America and Europe. Approximately two-thirds of the haemolysis produced by the peristaltic-type pump seemed to be secondary to the use of an antisiphon valve (ASV) on the transfusion line recommended by the manufacturer. Potassium levels did not increase with the use of the pumps. Modern infusion pumps widely used in hospitals in Quebec and elsewhere produce non-threatening levels of haemolysis during the transfusion of packed RBCs aged from 10 to 28 days. ASVs appear to induce additional haemolysis, and we do not recommend using them for blood transfusion. © 2017 International Society of Blood Transfusion.

  11. Infusion of iloprost without a peristaltic pump: Safety and tolerability

    Directory of Open Access Journals (Sweden)

    Paola Faggioli

    2013-04-01

    Full Text Available Introduction: Iloprost is a potent prostacyclin (PGI2 analogue that is effective in the treatment of peripheral arterial disease, vasculitis, pulmonary hypertension, and secondary Raynaud’s phenomenon. Intravenous infusions are generally administered with the aid of a peristaltic pump to reduce the risk of adverse reactions caused by unintentional increases in the infusion rate. This increases the cost of care in terms of equipment and personnel and may limit the use of this drug. Materials and methods: We retrospectively analyzed 18,432 iloprost infusions administered between 1999 and 2009 to 272 patients with systemic sclerosis (n = 253 and 19 with peripheral arterial disease (n = 19. All infusions were administered in the day hospital over 6 h with a normal IV set-up with a roller flow regulator. Flow rates were set to deliver iloprost at 1-2 ng/kg/min. Rates were verified by direct drop counts during the first 15-20 minutes of the infusion and at each subsequent check. Results: There were no adverse events that were fatal, life-threatening, or associated with prolongation of hospitalization and very few events requiring intensive care or continuous monitoring. The latter included 4 cases of tachycardia/arrhythmia (extrasystoles in most cases, 3 cases of hypotension (systolic pressure < 80 mmHg, and 2 cases of hypertension (BP > 170/100 mmHg. All other adverse reactions were mild, reversible, and similar to those seen with iloprost infusion with peristaltic pump. Only one patient had to be switched to another prostanoid (due to intolerance. Discussion: Iloprost infusion administered with a normal IV flow regulator appears to be as safe, well tolerated, and effective as traditional infusion with a peristaltic pump.

  12. Platelet transfusion in chemotherapy patients: comparison of the effect of intravenous infusion pumps versus gravity transfusion.

    Science.gov (United States)

    Meess, A

    2015-01-01

    Platelet concentrates are given to patients suffering with severe thrombocytopenia usually by a gravity transfusion procedure. Increasing patient numbers that are in need of this treatment increase the pressure on hospital staff and space. In order to combat time issues, the use of medical devices such as intravenous infusion pumps are thought to be beneficial for time and simultaneously for safety in transfusion practices. By using infusion pumps, platelet concentrates can be transfused in less time and provide accurate volume measurements. Manufacturers of infusion pumps claim that these devices are safe to be used for blood products including platelet concentrates. However, published studies were performed on older models and newer devices are on the market now. The purpose of this study is to evaluate infusion pumps, which are claimed to be suitable for blood products and to investigate the impact the pumps had on platelets. Furthermore, the study revealed if the intravenous infusion pumps are safe to be used for platelet transfusion as claimed by manufacturers. A simulated transfusion was performed using the Carefusion Alaris GP Plus volumetric pump and Fresenius Kabi Volumat Agilia infusion pump. Samples were taken from expired platelet concentrates before and after passage through the pump. All samples were investigated for full blood count that included platelet count, mean platelet volume (MPV), platelet distribution width (PDW) and a plateletcrit (PCT). The samples were then centrifuged to achieve platelet-poor plasma and then tested for lactate dehydrogenase (LDH). A power calculation performed on the statistical power analysis program G*power indicated a requirement of 82 samples for a power of 80%. Statistical analysis was performed with the IBM SPSS statistic software. A paired sample t-test was used to calculate mean, standard deviation and P values for the infusion pumps used. The Wilcoxon Signed Rank Test was used to evaluate results that had a non

  13. Novel monorail infusion catheter for volumetric coronary blood flow measurement in humans: in vitro validation

    NARCIS (Netherlands)

    van 't Veer, M.; Adjedj, J.; Wijnbergen, I.; Tóth, G.G.; Rutten, M.C.M.; Barbato, E.; van Nunen, L.X.; Pijls, N.H.J.; de Bruyne, B.

    2016-01-01

    AIMS: The aim of this study is to validate a novel monorail infusion catheter for thermodilution-based quantitative coronary flow measurements. METHODS AND RESULTS: Based on the principles of thermodilution, volumetric coronary flow can be determined from the flow rate of a continuous saline

  14. Quality-improvement analytics for intravenous infusion pumps.

    Science.gov (United States)

    Skledar, Susan J; Niccolai, Cynthia S; Schilling, Dennis; Costello, Susan; Mininni, Nicolette; Ervin, Kelly; Urban, Alana

    2013-04-15

    The implementation of a smart-pump continuous quality-improvement (CQI) program across a large health system is described, with an emphasis on key metrics for outcomes analyses and program refinement. Three years ago, the University of Pittsburgh Medical Center health system launched a CQI initiative to help ensure the safe use of 6000 smart pumps in its 14 inpatient facilities. A centralized team led by pharmacists is responsible for the retrieval and interpretation of smart-pump data, which is continuously transmitted to a main server. CQI findings are regularly posted on the health system's interdisciplinary intranet. Monitored metrics include rates of compliance with preprogrammed infusion limits, the top 20 drugs involved in alerts, drugs associated with alert-override rates of ≥90%, numbers of alerts by infusion type, nurse responses to alerts, and alert rate per drug library update. Based on the collected CQI data and site-specific requests, four systemwide updates of the smart-pump drug library were performed during the first 18 months of the program, reducing "nuisance alerts" by about 10% per update cycle and enabling targeted interventions to reduce rapid-infusion errors, other adverse drug events (ADEs), and pump-programming workarounds. Over one 12-month period, bedside alerts prompted nurses to reprogram or cancel continuous infusions an average of 400 times per month, potentially averting i.v. medication ADEs. A smart-pump CQI program is an effective tool for enhancing the safety of i.v. medication administration. The ongoing refinement of the drug library through the development and implementation of key interventions promotes the growth and sustainability of the smart-pump initiative systemwide.

  15. Developing a System for Integraded Automatic Control of Mutiple Infusion Pumps : The Multiplex infusion system

    NARCIS (Netherlands)

    Doesburg, Frank

    2013-01-01

    Most errors in ICUs are related to intravenous (IV) therapy. Previous studies suggested that hard to operate infusion pumps and the high cognitive workload for ICU nurses contribute to these errors. Conventional IV therapy requires separate lumens for incompatible IV drugs. This often requires the

  16. Comparative analytics of infusion pump data across multiple hospital systems.

    Science.gov (United States)

    Catlin, Ann Christine; Malloy, William X; Arthur, Karen J; Gaston, Cindy; Young, James; Fernando, Sudheera; Fernando, Ruchith

    2015-02-15

    A Web-based analytics system for conducting inhouse evaluations and cross-facility comparisons of alert data generated by smart infusion pumps is described. The Infusion Pump Informatics (IPI) project, a collaborative effort led by research scientists at Purdue University, was launched in 2009 to provide advanced analytics and tools for workflow analyses to assist hospitals in determining the significance of smart-pump alerts and reducing nuisance alerts. The IPI system allows facility-specific analyses of alert patterns and trends, as well as cross-facility comparisons of alert data uploaded by more than 55 participating institutions using different types of smart pumps. Tools accessible through the IPI portal include (1) charts displaying aggregated or breakout data on the top drugs associated with alerts, numbers of alerts per device or care area, and override-to-alert ratios, (2) investigative reports that can be used to characterize and analyze pump-programming errors in a variety of ways (e.g., by drug, by infusion type, by time of day), and (3) "drill-down" workflow analytics enabling users to evaluate alert patterns—both internally and in relation to patterns at other hospitals—in a quick and efficient stepwise fashion. The formation of the IPI analytics system to support a community of hospitals has been successful in providing sophisticated tools for member facilities to review, investigate, and efficiently analyze smart-pump alert data, not only within a member facility but also across other member facilities, to further enhance smart pump drug library design. Copyright © 2015 by the American Society of Health-System Pharmacists, Inc. All rights reserved.

  17. Continuous quality improvement using intelligent infusion pump data analysis.

    Science.gov (United States)

    Breland, Burnis D

    2010-09-01

    The use of continuous quality-improvement (CQI) processes in the implementation of intelligent infusion pumps in a community teaching hospital is described. After the decision was made to implement intelligent i.v. infusion pumps in a 413-bed, community teaching hospital, drug libraries for use in the safety software had to be created. Before drug libraries could be created, it was necessary to determine the epidemiology of medication use in various clinical care areas. Standardization of medication administration was performed through the CQI process, using practical knowledge of clinicians at the bedside and evidence-based drug safety parameters in the scientific literature. Post-implementation, CQI allowed refinement of clinically important safety limits while minimizing inappropriate, meaningless soft limit alerts on a few select agents. Assigning individual clinical care areas (CCAs) to individual patient care units facilitated customization of drug libraries and identification of specific CCA compliance concerns. Between June 2007 and June 2008, there were seven library updates. These involved drug additions and deletions, customization of individual CCAs, and alterations of limits. Overall compliance with safety software use rose over time, from 33% in November 2006 to over 98% in December 2009. Many potentially clinically significant dosing errors were intercepted by the safety software, prompting edits by end users. Only 4-6% of soft limit alerts resulted in edits. Compliance rates for use of infusion pump safety software varied among CCAs over time. Education, auditing, and refinement of drug libraries led to improved compliance in most CCAs.

  18. A review of the security of insulin pump infusion systems.

    Science.gov (United States)

    Paul, Nathanael; Kohno, Tadayoshi; Klonoff, David C

    2011-11-01

    Insulin therapy has enabled patients with diabetes to maintain blood glucose control to lead healthier lives. Today, rather than injecting insulin manually using syringes, a patient can use a device such as an insulin pump to deliver insulin programmatically. This allows for more granular insulin delivery while attaining blood glucose control. Insulin pump system features have increasingly benefited patients, but the complexity of the resulting system has grown in parallel. As a result, security breaches that can negatively affect patient health are now possible. Rather than focus on the security of a single device, we concentrate on protecting the security of the entire system. In this article, we describe the security issues as they pertain to an insulin pump system that includes an embedded system of components, which include the insulin pump, continuous glucose management system, blood glucose monitor, and other associated devices (e.g., a mobile phone or personal computer). We detail not only the growing wireless communication threat in each system component, but also describe additional threats to the system (e.g., availability and integrity). Our goal is to help create a trustworthy infusion pump system that will ultimately strengthen pump safety, and we describe mitigating solutions to address identified security issues. © 2011 Diabetes Technology Society.

  19. Assessment of implantable infusion pumps for continuous infusion of human insulin in rats: potential for group housing

    DEFF Research Database (Denmark)

    Jensen, Vivi Flou Hjorth; Molck, Anne-Marie; Martensson, Martin

    2017-01-01

    compound in these studies, and a comparator model of persistent exposure by HI infusion from external pumps has recently been developed to support toxicological evaluation of long-acting insulin analogues. However, this model requires single housing of the animals. Developing an insulin-infusion model...... which allows group housing would therefore greatly improve animal welfare. The aim of the present study was to investigate the suitability of implantable infusion pumps for HI infusion in group-housed rats. Group housing of rats implanted with a battery-driven pump proved to be possible. Intravenous...... infusion of HI lowered blood glucose levels persistently for two weeks, providing a comparator model for use in two-week repeated-dose toxicity studies with new long-acting insulin analogues, which allows group housing, and thereby increasing animal welfare compared with an external infusion model....

  20. Haemolysis following rapid experimental red blood cell transfusion--an evaluation of two infusion pumps

    DEFF Research Database (Denmark)

    Hansen, Tom Giedsing; Sprogøe-Jakobsen, U; Pedersen, C M

    1998-01-01

    The vast majority of infusion pumps used for rapid transfusion of large amounts of blood have never been properly examined regarding their influence on the quality of the red blood cells (RBCs) infused. In this study, we evaluated the effect of two different infusion pumps on the degree of RBC...

  1. Comparative Dose Accuracy of Durable and Patch Insulin Infusion Pumps

    Science.gov (United States)

    Jahn, Luis G.; Capurro, Jorge J.; Levy, Brian L.

    2013-01-01

    Background: As all major insulin pump manufacturers comply with the international infusion pump standard EN 60601-2-24:1998, there may be a general assumption that all pumps are equal in insulin-delivery accuracy. This research investigates single-dose and averaged-dose accuracy of incremental basal deliveries for one patch model and three durable models of insulin pumps. Method: For each pump model, discrete single doses delivered during 0.5 U/h basal rate infusion over a 20 h period were measured using a time-stamped microgravimetric system. Dose accuracy was analyzed by comparing single doses and time-averaged doses to specific accuracy thresholds (±5% to ±30%). Results: The percentage of single doses delivered outside accuracy thresholds of ±5%, ±10%, and ±20% were as follows: Animas OneTouch® Ping® (43.2%, 14.3%, and 1.8%, respectively), Roche Accu-Chek® Combo (50.6%, 24.4%, and 5.5%), Medtronic Paradigm® RevelTM/VeoTM (54.2%, 26.7%, and 6.6%), and Insulet OmniPod® (79.1%, 60.5%, and 34.9%). For 30 min, 1 h, and 2 h averaging windows, the percentage of doses delivered outside a ±15% accuracy were as follows: OneTouch Ping (1.0%, 0.4%, and 0%, respectively), Accu-Chek Combo (4.2%, 3.5%, and 3.1%), Paradigm Revel/Veo (3.9%, 3.1%, and 2.2%), and OmniPod (33.9%, 19.9%, and 10.3%). Conclusions: This technical evaluation demonstrates significant differences in single-dose and averaged-dose accuracy among the insulin pumps tested. Differences in dose accuracy were most evident between the patch pump model and the group of durable pump models. Of the pumps studied, the Animas OneTouch Ping demonstrated the best single-dose and averaged-dose accuracy. Further research on the clinical relevance of these findings is warranted. PMID:23911184

  2. Using miniature osmotic infusion pumps to maintain tritiated thymidine exposure to cells in culture

    International Nuclear Information System (INIS)

    Neely, J.E.; Hake, D.A.

    1982-01-01

    To provide a constant level of tracer doses of tritiated thymidine to cultured cells during continuous infusion, miniature osmotic infusion pumps were used to provide replacement thymidine. By determining the loss of isotope from the media during nonreplacement, the rate of constant infusion replacement to maintain thymidine levels was calculated. The replacement rates were similar for the three cell lines examined and allowed a standard osmotic pump infusion

  3. Determination of 24-hour insulin infusion pattern by an artificial endocrine pancreas for intravenous insulin infusion with a miniature pump

    DEFF Research Database (Denmark)

    Kølendorf, K; Christiansen, J S; Bojsen, J

    1981-01-01

    UNLABELLED: Intravenous insulin infusion with a glucose controlled insulin infusion system (GCIIS) is known to restore glucose homeostasis. A simpler approach to improve blood glucose regulation is preprogrammed intravenous insulin infusion with portable pumps without sensor-mediated feedback. We...... report a study designed to evaluate whether the preprogrammed insulin infusion pattern to be used in the miniature insulin infusion pump (MIIP) could be optimized by concomitant employment of the GCIIS for blood glucose control. Six juvenile-onset insulin-dependent diabetics (mean age 31 yrs) were...... studied. Mean blood glucose (MBG) was 6.2 mmol/l +/- 0.5 (SD) during glucose controlled infusion and 5.3 +/- 0.6 during the combined MIIP + GCIIS-day. The insulin requirements calculated from the s.c. regimen (56 U +/- 10 SD) were identical to the GCIIS-measured (51 U +/- 14) and to the amounts delivered...

  4. Novel monorail infusion catheter for volumetric coronary blood flow measurement in humans: in vitro validation.

    Science.gov (United States)

    van 't Veer, Marcel; Adjedj, Julien; Wijnbergen, Inge; Tóth, Gabor G; Rutten, Marcel C M; Barbato, Emanuele; van Nunen, Lokien X; Pijls, Nico H J; De Bruyne, Bernard

    2016-08-20

    The aim of this study is to validate a novel monorail infusion catheter for thermodilution-based quantitative coronary flow measurements. Based on the principles of thermodilution, volumetric coronary flow can be determined from the flow rate of a continuous saline infusion, the temperature of saline when it enters the coronary artery, and the temperature of the blood mixed with the saline in the distal part of the coronary artery. In an in vitro set-up of the systemic and coronary circulation at body temperature, coronary flow values were varied from 50-300 ml/min in steps of 50 ml/min. At each coronary flow value, thermodilution-based measurements were performed at infusion rates of 15, 20, and 30 ml/min. Temperatures and pressures were simultaneously measured with a pressure/temperature sensor-tipped guidewire. Agreement of the calculated flow and the measured flow as well as repeatability were assessed. A total of five catheters were tested, with a total of 180 measurements. A strong correlation (ρ=0.976, p<0.0001) and a difference of -6.5±15.5 ml/min were found between measured and calculated flow. The difference between two repeated measures was 0.2%±8.0%. This novel infusion catheter used in combination with a pressure/temperature sensor-tipped guidewire allows accurate and repeatable absolute coronary flow measurements. This opens a window to a better understanding of the coronary microcirculation.

  5. Strontium-rubidium infusion pump with in-line dosimetry

    International Nuclear Information System (INIS)

    Barker, S.L.; Loberg, M.D.

    1986-01-01

    A strontium-rubidium infusion system is described which consists of: (a) means for generating rubidium 82 in a solution which can be infused into a patient; (b) means for infusing the solution into a patient; (c) means for measuring the radioactivity present in the solution as it is infused into the patient; and (d) means for controlling the means for infusing in response to the amount of radioactivity which has been infused into the patient

  6. Determination of Volumetric Losses in Hydrodynamic Pump Using Numerical Modelling

    Directory of Open Access Journals (Sweden)

    Lukáš ZAVADIL

    2012-06-01

    Full Text Available This paper deals with the numerical modelling of the flow in the single-stage centrifugal pump. The main objective is to determine leakage losses through annular seals at the suction side of the pump. Leakage through a shaft seal is not included in the simulation. The amount of liquid that circulates from the impeller discharge back to suction of the pump is determined in dependence on the flow rate. Losses in the pump are further discussed as well as the possibility of their prediction.

  7. Graphical user interface simplifies infusion pump programming and enhances the ability to detect pump-related faults.

    Science.gov (United States)

    Syroid, Noah; Liu, David; Albert, Robert; Agutter, James; Egan, Talmage D; Pace, Nathan L; Johnson, Ken B; Dowdle, Michael R; Pulsipher, Daniel; Westenskow, Dwayne R

    2012-11-01

    Drug administration errors are frequent and are often associated with the misuse of IV infusion pumps. One source of these errors may be the infusion pump's user interface. We used failure modes-and-effects analyses to identify programming errors and to guide the design of a new syringe pump user interface. We designed the new user interface to clearly show the pump's operating state simultaneously in more than 1 monitoring location. We evaluated anesthesia residents in laboratory and simulated environments on programming accuracy and error detection between the new user interface and the user interface of a commercially available infusion pump. With the new user interface, we observed the number of programming errors reduced by 81%, the number of keystrokes per task reduced from 9.2 ± 5.0 to 7.5 ± 5.5 (mean ± SD), the time required per task reduced from 18.1 ± 14.1 seconds to 10.9 ± 9.5 seconds and significantly less perceived workload. Residents detected 38 of 70 (54%) of the events with the new user interface and 37 of 70 (53%) with the existing user interface, despite no experience with the new user interface and extensive experience with the existing interface. The number of programming errors and workload were reduced partly because it took less time and fewer keystrokes to program the pump when using the new user interface. Despite minimal training, residents quickly identified preexisting infusion pump problems with the new user interface. Intuitive and easy-to-program infusion pump interfaces may reduce drug administration errors and infusion pump-related adverse events.

  8. Clinical safety of magnetic resonance imaging in patients with implanted SynchroMed EL infusion pumps

    International Nuclear Information System (INIS)

    Diehn, Felix E.; Wood, Christopher P.; Watson, Robert E.; Hunt, Christopher H.; Mauck, William D.; Burke, Michelle M.

    2011-01-01

    Patients with implanted SynchroMed spinal infusion pumps (Medtronic, Inc., Minneapolis, MN) routinely undergo magnetic resonance imaging at our institution. In August 2008, Medtronic issued an urgent medical device correction report regarding several pumps. Because of the rare potential ''for a delay in the return of proper drug infusion'' and ''for a delay in the logging of motor stall events,'' ''a patient's pump must be interrogated after MRI exposure in order to confirm proper pump functionality.'' This is particularly important in patients receiving intrathecal baclofen, for whom a delay in return of proper pump infusion could lead to life-threatening baclofen withdrawal syndrome. The objective of this report is to present our experience and protocol of performing magnetic resonance imaging in patients with implanted SynchroMed EL pumps. We retrospectively reviewed records of 86 patients with implanted SynchroMed EL spinal infusion pumps who underwent 112 examinations on 1.5-T magnetic resonance imaging scanners from September 1, 1998 to July 7, 2004. No SynchroMed EL pumps were damaged by magnetic resonance imaging, and the programmable settings remained unchanged in all patients. Our data suggest that SynchroMed EL pump malfunction is indeed rare after routine clinical 1.5-T magnetic resonance imaging examinations. However, based on the Medtronic correction report, we perform pump interrogation before and after imaging. (orig.)

  9. Clinical safety of magnetic resonance imaging in patients with implanted SynchroMed EL infusion pumps

    Energy Technology Data Exchange (ETDEWEB)

    Diehn, Felix E.; Wood, Christopher P.; Watson, Robert E.; Hunt, Christopher H. [Mayo Clinic, Department of Radiology, Rochester, MN (United States); Mauck, William D. [Mayo Clinic, Department of Anesthesiology, Rochester, MN (United States); Burke, Michelle M. [Mayo Clinic, Department of Psychiatry and Psychology, Rochester, MN (United States)

    2011-02-15

    Patients with implanted SynchroMed spinal infusion pumps (Medtronic, Inc., Minneapolis, MN) routinely undergo magnetic resonance imaging at our institution. In August 2008, Medtronic issued an urgent medical device correction report regarding several pumps. Because of the rare potential ''for a delay in the return of proper drug infusion'' and ''for a delay in the logging of motor stall events,'' ''a patient's pump must be interrogated after MRI exposure in order to confirm proper pump functionality.'' This is particularly important in patients receiving intrathecal baclofen, for whom a delay in return of proper pump infusion could lead to life-threatening baclofen withdrawal syndrome. The objective of this report is to present our experience and protocol of performing magnetic resonance imaging in patients with implanted SynchroMed EL pumps. We retrospectively reviewed records of 86 patients with implanted SynchroMed EL spinal infusion pumps who underwent 112 examinations on 1.5-T magnetic resonance imaging scanners from September 1, 1998 to July 7, 2004. No SynchroMed EL pumps were damaged by magnetic resonance imaging, and the programmable settings remained unchanged in all patients. Our data suggest that SynchroMed EL pump malfunction is indeed rare after routine clinical 1.5-T magnetic resonance imaging examinations. However, based on the Medtronic correction report, we perform pump interrogation before and after imaging. (orig.)

  10. Outlook Analgesic Infusion Pumps Market Size - Trends and Opportunity Forecast to 2023

    OpenAIRE

    nishthavohra

    2018-01-01

    Analgesic infusion pumps are instruments used to carry analgesic drugs directly into patient’s body directly for pain management. Analgesic drugs provide relief from chronic disorders, including complex regional pain syndrome (CRPS), failed back syndrome pain, myocardial infarction, pneumonia, myocardial ischemia, post-operative pain, and hypertension. Lidocaine, phenol and morphine are some of the common medicines used in analgesic infusion pumps. Explore Report At: https://www.psmarket...

  11. The flow Rate Accuracy of Elastomeric Infusion Pumps After Repeated Filling.

    Science.gov (United States)

    Mohseni, Masood; Ebneshahidi, Amin

    2014-05-01

    One of the frequent applications of elastomeric infusion pumps is postoperative pain management. In daily practice, the disposable pumps get refilled with modified medication combinations in the successive days; although, the accuracy of infusion rates is unknown to clinicians. Our aim was to evaluate the effect of repeated filling on the delivery rate accuracy of an elastomeric pump available in our market. We examined 10 elastomeric infusion pumps (BOT-802, Nanchang Biotek Medical Device Company, China) with 100 mL capacity and nominal flow of 5 mL/h. Each pump was filled for three times, accounting for 30 series of experiments. A microset scaled in mL was used to measure the pump deliveries. Flow profile and reliability of infusion rate were analyzed after repeated use. The mean flow rate in the three series of measurements showed a gradual increase; however, the difference was not statistically significant (5.01 ± 0.07 vs. 5.03 ± 0.06 vs. 5.06 ± 0.08 mL/h; P = 0.81). The percentage of the flow rate error (deviation from 5 mL/h ± 15%) was 100% in the first and second hours of infusion, 96% in the third hour, 60% in the 20th hour and zero percent in the rest of the infusion time. This study indicated that the delivery rate accuracy of elastomeric infusion pumps is preserved after repeated usage. These laboratory findings suggested that elastomeric pumps could be safely refilled in the successive days to provide postoperative analgesia.

  12. Optimization of intelligent infusion pump technology to minimize vasopressor pump programming errors.

    Science.gov (United States)

    Vadiei, Nina; Shuman, Carrie A; Murthy, Manasa S; Daley, Mitchell J

    2017-08-01

    There is a lack of data evaluating the impact of hard limit implementation into intelligent infusion pump technology (IIPT). The purpose of this study was to determine if incorporation of vasopressor upper hard limits (UHL) into IIPT increases efficacy of alerts by preventing pump programming errors. Retrospective review from five hospitals within a single healthcare network between April 1, 2013 and May 31, 2014. A total of 65,680 vasopressor data entries were evaluated; 19,377 prior to hard limit implementation and 46,303 after hard limit implementation. The primary outcome was the percent of effective alerts. The secondary outcome was the proportional dose increase from the soft limit provided. A reduction in alert rate occurred after incorporation of hard limits to the IIPT drug library (pre-UHL 4.7% vs. post-UHL 4.0%) with a subsequent increase in the number of errors prevented as represented by a higher effective alert rate (pre-UHL 23.0% vs. post-UHL 37.3%; p < 0.001). The proportional dose increase was significantly reduced (pre-UHL 188% ± 380%] vs. post-UHL 95% ± 128%; p < 0.001). Incorporation of UHLs into IIPT in a multi-site health system with varying intensive care unit and emergency department acuity increases alert effectiveness, reduces dosing errors, and reduces the magnitude of dosing errors that reach the patient.

  13. Insulin appearance of subcutaneously infused insulin: influence of the basal rate pulse interval of the infusion pump.

    Science.gov (United States)

    Birch, K; Hildebrandt, P; Jensen, B M; Kühl, C; Brange, J

    1985-05-01

    To compare the metabolic control and the pharmacokinetics of infused insulin using an insulin pump (Auto-Syringe AS 6C) which provides the basal rate in pulses every 2-10 min with a pump (Medix Syringe Driver 209) providing the basal rate in pulses every 15-60 min, 6 C-peptide negative diabetic patients received, in random order, identical, but individual, insulin treatment during one 4-day period using the Auto-Syringe pump and another 4-day period using the Medix pump. On the fourth day of each period, blood glucose and plasma-free insulin were estimated every 30 min for 7 hr and every 5 min for the next hour. Plasma-free insulin was significantly higher on 3 time points out of the 26 possible when using the Medix pump, but this was not reflected in the blood glucose concentrations which were similar in the 2 periods. The results indicate that, from a metabolic and pharmacokinetic point of view, insulin pumps working with larger intervals between the basal rate pulses are just as good as the more technically advanced and hence often more expensive pumps which provide the basal rate in more and smaller pulses.

  14. Physical and Chemical Stability of Urapidil in 0.9% Sodium Chloride in Elastomeric Infusion Pump.

    Science.gov (United States)

    Tomasello, Cristina; Leggieri, Anna; Rabbia, Franco; Veglio, Franco; Baietto, Lorena; Fulcheri, Chiara; De Nicolò, Amedeo; De Perri, Giovanni; D'Avolio, Antonio

    2016-01-01

    Urapidil is an antihypertensive agent, usually administered through intravenous bolus injection, slow-intravenous infusion, or continuous-drug infusion by perfusor. Since to date no evidences are available on drug stability in elastomeric pumps, patients have to be hospitalized. The purpose of this study was to validate an ultra-performance liquid chromatographic method to evaluate urapidil stability in an elastomeric infusion pump, in order to allow continuous infusion as home-care treatment. Analyses were conducted by diluting urapidil in an elastomeric pump. Two concentrations were evaluated: 1.6 mg/mL and 3.3 mg/mL. For the analyses, a reverse-phase ultra-performance liquid chromatographic- photodiode array detection instrument was used. Stressed degradation, pH changes, and visual clarity were used as stability indicators up to 10 days after urapidil solution preparation. The drug showed no more than 5% degradation during the test period at room temperature. No pH changes and no evidences of incompatibility were observed. Stress tests resulted in appreciable observation of degradation products. Considering the observed mean values, urapidil hydrochloride in sodium chloride 0.9% in elastomeric infusion pumps is stable for at least 10 days. These results indicate that this treatment could be administered at home for a prolonged duration (at least 7 days) with a satisfactory response. Copyright© by International Journal of Pharmaceutical Compounding, Inc.

  15. [Incorrect programming of a target controlled infusion pump. Case SENSAR of the trimester].

    Science.gov (United States)

    2014-10-01

    We report the case of a patient who underwent surgical aortic valve replacement. During general anaesthesia maintenance, the patient received a remifentanyl infusion via a target controlled infusion (TCI) system. The infusion pump that was prepared to deliver the infusion showed malfunction at the beginning of the surgery, so it was quickly replaced with a second pump. After a few minutes into the surgery, the patient presented with hypotension refractory to treatment. The remifentanyl syringe also emptied faster than expected. On reviewing the TCI pump, it was found that it was erroneously programmed for propofol instead of remifentanyl, thus the patient had received a very high dose of remifentanyl that was probably the cause of the haemodynamic disturbances. The incident was an error in equipment use, facilitated by hurry, lack of checking of the equipment prior to its use, and the complex and unclear design of the devices' screens. After analysis of this incident, all TCI pumps were reviewed, and all the programs for infrequently used drugs were deleted. Furthermore, 2 pumps were selected for exclusive use in the cardiac surgery theatre, one with propofol-only programming, and the other with remifentanyl-only programming, both clearly marked and situated in fixed places in that theatre. Copyright © 2014 Sociedad Española de Anestesiología, Reanimación y Terapéutica del Dolor. Published by Elsevier España. All rights reserved.

  16. In vitro viability effects on apheresis and buffy-coat derived platelets administered through infusion pumps

    Directory of Open Access Journals (Sweden)

    Sandgren P

    2014-12-01

    Full Text Available Per Sandgren,1,2 Veronica Berggren,3 Carl Westling,1,2 Viveka Stiller1 1Department of Clinical Immunology and Transfusion Medicine, Karolinska University Hospital, 2Department of Laboratory Medicine, Karolinska Institutet, 3Department of Neonatology, Karolinska University Hospital, Stockholm, SwedenBackground: Different infusion pump systems as well as gravity infusion have been widely used in neonatal transfusion. However, the limited number of published studies describing the use of infusion pumps on platelets illustrates the necessity for more robust data.Methods: To evaluate the potential in vitro effects on the cellular, metabolic, functional and phenotypic properties of platelets, we set up a four-arm paired study simultaneously comparing the use of different infusion pumps (Alaris® CC/GP with unexposed platelets. The platelet units (n=8 were either produced by the apheresis technique and suspended in 100% plasma or derived from buffy coats to yield platelet units stored in approximately 30% plasma and 70% SSP+. Fresh and 5-day old platelets were tested.Results: Regardless of the production system or storage time used, no significant differences were observed in glucose and lactate concentration, pH, adenosine triphosphate levels, response to extent of shape change, hypotonic shock response reactivity, and CD62P expression. Similarly, no differences were observed in expression of the conformational epitope on glycoprotein IIb/IIIa, determined using procaspase-activating compound 1, or in the expression of CD42b and platelet-endothelial cell adhesion molecule-1 in a comparison between platelets administered through infusion pumps versus unexposed platelets.Conclusion: Using Alaris CC/GP infusion pumps had no influence on the cellular, functional, and phenotypic in vitro properties of platelets. This fact seems not to be affected by different production systems or storage time.Keywords: platelets, neonatal platelet transfusion

  17. [A Quantitative Verification for Operability of Three PCA Devices Attached to the Disposable Infusion Pumps].

    Science.gov (United States)

    Tadokoro, Takahiro; Fuchibe, Makoto; Odo, Yuichiro; Kakinohana, Manabu

    2015-11-01

    In this study using 3 different PCA devices (Baxter infuser LVBB +PCM 2 ml: Pump B, Coopdech Balloonjector +PCA 3 ml: Pump C, Rakuraku fuser +PCA 3 ml: Pump S), we investigated how easily PCA devices could be handled. In this study with 42 volunteers (14 elders and 28 nurses), we compared 3 PCA ejection volume and ejection rate among three PCA devices. PCA ejection rate was defined as the ratio of actual ejection volume to the maximum ejection volume (MEV) of each PCA device. Although not only elders but also nurses failed to produce accurate PCA ejection volume in the Pump B, Pump S could provide the MEV even by elders. In the Pump C, approximately 80% of MEV could be achieved by nurses, but 60% of MEV by elders (P PCA ejection volume might be dependent on PCA device.

  18. Impact of Computerized Order Entry to Pharmacy Interface on Order-Infusion Pump Discrepancies

    Directory of Open Access Journals (Sweden)

    Rebecca A. Russell

    2015-01-01

    Full Text Available Background. The ability of safety technologies to decrease errors, harm, and risk to patients has yet to be demonstrated consistently. Objective. To compare discrepancies between medication and intravenous fluid (IVF orders and bedside infusion pump settings within a pediatric intensive care unit (PICU before and after implementation of an interface between computerized physician order entry (CPOE and pharmacy systems. Methods. Within a 72-bed PICU, medication and IVF orders in the CPOE system and bedside infusion pump settings were collected. Rates of discrepancy were calculated and categorized by type. Results were compared to a study conducted prior to interface implementation. Expansion of PICU also occurred between study periods. Results. Of 455 observations, discrepancy rate decreased for IVF (p=0.01 compared to previous study. Overall discrepancy rate for medications was unchanged; however, medications infusing without an order decreased (p<0.01, and orders without corresponding infusion increased (p<0.05. Conclusions. Following implementation of an interface between CPOE and pharmacy systems, fewer discrepancies between IVF orders and infusion pump settings were observed. Discrepancies for medications did not change, and some types of discrepancies increased. In addition to interface implementation, changes in healthcare delivery and workflow related to ICU expansion contributed to observed changes.

  19. Iloprost infusion by a new device as a portable syringe pump: safety, tolerability and agreement

    Directory of Open Access Journals (Sweden)

    Paola Faggioli

    2012-12-01

    Full Text Available Background Iloprost, prostacyclin (PGI2 analogue, effective in treatment of peripheral arterial disease, secondary Raynaud's phenomenon (RP to connective tissue disease (CTD, vasculitis, pulmonary hypertension, is usually infused through peristaltic pump, or recently through a flow regulator.Materials and methods We tested a new portable syringe pump (Pompa Infonde®, Italfarmaco S.p.A., Cinisello Balsamo, Milano on 120 patients affected by RP to CTD and cryoglobulinaemia, in iloprost therapy with a flow regulator.Results Iloprost infused through portable syringe pump is better tolerated, better appreciated by the patients and nurses and no difference was observed on therapeutic effects, with a lower incidence of side effects statistically significant. Only 3 patients were unable to tolerate the device (2 for changes in pressure and 1 for fear and shifted to traditional method of iloprost infusion.Conclusions Iloprost infusion through the portable syringe Pompa Infonde® appears to be safe, better tolerated, more acceptable and equally effective compared to infusion through a flow regulator.

  20. Model of a thermal driven volumetric pump for energy harvesting in an underwater glider

    International Nuclear Information System (INIS)

    Falcão Carneiro, J.; Gomes de Almeida, F.

    2016-01-01

    Underwater gliders are one of the most promising approaches to achieve an increase of human presence in the oceans. Among existing solutions, thermal driven gliders present long range and endurance capabilities, offering the possibility of remaining years beneath water collecting and transmitting data to shore. A key component in thermal gliders lies in the process used to collect ocean's thermal energy. In this paper a new quasi-static model of a thermal driven volumetric pump, for use in underwater gliders, is presented. The study also encompasses an analysis of the influence different hydraulic system parameters have on the thermodynamic cycle efficiency. Finally, the paper proposes a simple dynamic model of a heat exchanger that uses commercially available materials for the Phase Change Material (PCM) container. Simulation results validate the models developed. - Highlights: • A new model of a thermal driven volumetric pump for underwater gliders is proposed. • The effect hydraulic system parameters have on the cycle efficiency is analyzed. • The energy efficiency may be increased tenfold using adequate hydraulic parameters. • It's shown that the PCM PVT transition surface may not alter the cycle efficiency.

  1. Safety and efficacy of gas-forced infusion (air pump) in coaxial phacoemulsification.

    Science.gov (United States)

    Chaudhry, Prashaant; Prakash, Gaurav; Jacob, Soosan; Narasimhan, Smita; Agarwal, Sunita; Agarwal, Amar

    2010-12-01

    To evaluate the safety and efficacy of gas-forced infusion (air pump) in uncomplicated coaxial phacoemulsification. Dr. Agarwal's Eye Hospital, Chennai, India. Comparative case series. Specular microscopy and optical coherence tomography were used to analyze the endothelium, central macular thickness (CMT), and peripapillary retinal nerve fiber layer (RNFL) thickness before and approximately 1, 7, 30, and 90 days after coaxial phacoemulsification with (infusion group) or without (control group) gas-forced infusion. Surgical time, surge, phaco energy, irrigation fluid volume, surgical ease, complications, and visual gain in the 2 groups were compared. The mean endothelial cell loss was lower in the infusion group than in the control group (6.98% ± 8.46% [SD] versus 10.54% ± 11.24%; P = .045) and the irrigation/aspiration time significantly shorter (54 ± 39 seconds versus 105 ± 84 seconds; P = .0001). The surgery was rated as easier with gas-forced infusion (scale 1 to 10: mean 8.3 ± 2.1 versus 6.6 ± 1.6; P = .00002). However, the amount of irrigating fluid volume was higher in the infusion group (117 ± 37 mL versus 94 ± 41 mL; P = .003). No surge occurred in the infusion group; it occurred a mean of 3.00 ± 4.16 times in the control group (PGas-forced infusion was safe and effective in controlling surge and increased the safety, ease, and speed of coaxial phacoemulsification. Copyright © 2010 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  2. Single-dose volume regulation algorithm for a gas-compensated intrathecal infusion pump.

    Science.gov (United States)

    Nam, Kyoung Won; Kim, Kwang Gi; Sung, Mun Hyun; Choi, Seong Wook; Kim, Dae Hyun; Jo, Yung Ho

    2011-01-01

    The internal pressures of medication reservoirs of gas-compensated intrathecal medication infusion pumps decrease when medication is discharged, and these discharge-induced pressure drops can decrease the volume of medication discharged. To prevent these reductions, the volumes discharged must be adjusted to maintain the required dosage levels. In this study, the authors developed an automatic control algorithm for an intrathecal infusion pump developed by the Korean National Cancer Center that regulates single-dose volumes. The proposed algorithm estimates the amount of medication remaining and adjusts control parameters automatically to maintain single-dose volumes at predetermined levels. Experimental results demonstrated that the proposed algorithm can regulate mean single-dose volumes with a variation of 98%. © 2010, Copyright the Authors. Artificial Organs © 2010, International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  3. Insulin compatibility with polymer materials used in external pump infusion systems.

    Science.gov (United States)

    Melberg, S G; Havelund, S; Villumsen, J; Brange, J

    1988-04-01

    In a study designed to mimic actual user conditions for external insulin pump infusion, the insulin quality after passage through the infusion set was assessed by various analytical methods, including high performance liquid chromatography. The two infusion sets tested consisted of, firstly, a polyvinylchloride/rubber syringe and a polyvinylchloride catheter sterilized by gamma irradiation and, secondly, a polyethylene/polypropylene syringe connected to a polyethylene catheter and sterilized by ethylene oxide. The insulin solution delivered through the PVC infusion set showed a reduction of preservative to less than 30% of the initial content and increased formation of chemical transformation products of insulin varying from twice the reference level during the first day to more than three times on the third day. By contrast, the polyethylene/polypropylene infusion system showed only a minor decrease in preservative content and no increase in chemical transformation. These effects were observed irrespective of the brand of insulin and were not affected by increase of the zinc content of the insulin solution. Investigation of the influence of the sterilization methods performed on polyvinylchloride and polyethylene catheters revealed that gamma irradiated polyvinylchloride catheters were markedly harmful to the insulin solution, whereas ethylene oxide sterilization did not influence the chemical stability of insulin.

  4. Organizational, Cultural, and Psychological Determinants of Smart Infusion Pump Work Arounds: A Study of 3 U.S. Health Systems.

    Science.gov (United States)

    Dunford, Benjamin B; Perrigino, Matthew; Tucker, Sharon J; Gaston, Cynthia L; Young, Jim; Vermace, Beverly J; Walroth, Todd A; Buening, Natalie R; Skillman, Katherine L; Berndt, Dawn

    2017-09-01

    We investigated nurse perceptions of smart infusion medication pumps to provide evidence-based insights on how to help reduce work around and improve compliance with patient safety policies. Specifically, we investigated the following 3 research questions: (1) What are nurses' current attitudes about smart infusion pumps? (2) What do nurses think are the causes of smart infusion pump work arounds? and (3) To whom do nurses turn for smart infusion pump training and troubleshooting? We surveyed a large number of nurses (N = 818) in 3 U.S.-based health care systems to address the research questions above. We assessed nurses' opinions about smart infusion pumps, organizational perceptions, and the reasons for work arounds using a voluntary and anonymous Web-based survey. Using qualitative research methods, we coded open-ended responses to questions about the reasons for work arounds to organize responses into useful categories. The nurses reported widespread satisfaction with smart infusion pumps. However, they reported numerous organizational, cultural, and psychological causes of smart pump work arounds. Of 1029 open-ended responses to the question "why do smart pump work arounds occur?" approximately 44% of the causes were technology related, 47% were organization related, and 9% were related to individual factors. Finally, an overwhelming majority of nurses reported seeking solutions to smart pump problems from coworkers and being trained primarily on the job. Hospitals may significantly improve adherence to smart pump safety features by addressing the nontechnical causes of work arounds and by providing more leadership and formalized training for resolving smart pump-related problems.

  5. Tolerability, safety and efficacy of Iloprost infusion without peristaltic pump in systemic sclerosis

    Directory of Open Access Journals (Sweden)

    S. Tosi

    2011-09-01

    Full Text Available Objective. To evaluate safety, tolerability and efficacy on Raynaud’s phenomenon (Rp of iloprost infusion without peristaltic pump in patients with systemic sclerosis (SSc. Patients and methods. The inclusion criteria were diagnosis of SSc, age between 18 and 65 years, presence of Rp, and absence of any controindication to the use of iloprost. The treatment was carried out in a day hospital setting and consisted first of 5 consecutive days of iloprost infusion (from an initial dose of 1.0 ng/Kg/min up to 2 ng/kg/min, and then of 2 days of infusions at the maximum possible dose every 45 days for one year. All of the adverse events were carefully recorded and the changes in the Rp were measured by a 5 grade scale (worsened, unmodified, slightly improved, very improved, disappeared. Results. Thirty-eight SSc patients (all females, mean age 49 years (range 18.5-65, disease duration 1.5 years (range 0.5-10.8 were enrolled in the study. During the first cycle of therapy, 14 avderse events occurred in 11 (28.9% patients and during the next cycles, 3 adverse events were seen in 3 (7.9% patients. In all of the cases they were mild and transient. Rp was considered very improved in 15 (39.5% patients, slightly improved in 13 (34.2%, unmodified in 8 (21% and worse in 2 (5.2%. Discussion. In this study intravenous iloprost without peristaltic pump proved to be safe, well tolerated, and as effective as traditional infusion through peristaltic pump in improving Rp in patients with SSc.

  6. Adequate plasma drug concentrations suggest that amoxicillin can be administered by continuous infusion using elastomeric pumps.

    Science.gov (United States)

    Arensdorff, Lyne; Boillat-Blanco, Noémie; Decosterd, Laurent; Buclin, Thierry; de Vallière, Serge

    2017-09-01

    Elastomeric pumps can be useful for the administration of antibiotics in the outpatient setting. To determine amoxicillin degradation in elastomeric pumps, as well as the effectiveness of amoxicillin treatment administered by elastomeric pumps. Antibiotic degradation was measured in elastomeric pumps filled with 6 g of amoxicillin in 240 mL of NaCl 0.9% by drawing samples at 12 h intervals when stored in the fridge for 48 h and when worn around the waist for 24 h. Subsequently nine patients were treated with continuous infusions of 8 or 12 g of amoxicillin per day. Plasma amoxicillin concentrations were measured on each visit to the outpatient parenteral antibiotic therapy unit. Clinical outcome was verified 3 months after the end of treatment. Amoxicillin degradation in elastomeric pumps reached 10% after 48 h in the fridge and an additional 30% when worn around the waist for 24 h. Mean plasma drug concentrations achieved with 12 g of amoxicillin per day were 18.5 mg/L (95% CI 13.5-23.5), which is largely above the MIC of amoxicillin-susceptible bacteria. Nine patients treated for various complicated infections were cured and had no unexpected adverse effects. Adequate plasma drug concentrations and favourable clinical outcomes suggest that amoxicillin can be administered by continuous infusion using elastomeric pumps. This treatment modality does not fulfil formal requirements regarding pharmaceutical stability, but the resulting safety impact in patients is probably limited. Therapeutic drug monitoring and a close clinical follow-up are recommended if this route of administration is chosen. © The Author 2017. Published by Oxford University Press on behalf of the British Society for Antimicrobial Chemotherapy. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  7. Benefits of smart pumps for automated changeovers of vasoactive drug infusion pumps: a quasi-experimental study.

    Science.gov (United States)

    Cour, M; Hernu, R; Bénet, T; Robert, J M; Regad, D; Chabert, B; Malatray, A; Conrozier, S; Serra, P; Lassaigne, M; Vanhems, P; Argaud, L

    2013-11-01

    Manual changeover of vasoactive drug infusion pumps (CVIP) frequently lead to haemodynamic instability. Some of the newest smart pumps allow automated CVIP. The aim of this study was to compare automated CVIP with manual 'Quick Change' relays. We performed a prospective, quasi-experimental study, in a university-affiliated intensive care unit (ICU). All adult patients receiving continuous i.v. infusion of vasoactive drugs were included. CVIP were successively performed manually (Phase 1) and automatically (Phase 2) during two 6-month periods. The primary endpoint was the frequency of haemodynamic incidents related to the relays, which were defined as variations of mean arterial pressure >15 mm Hg or heart rate >15 bpm. The secondary endpoints were the nursing time dedicated to relays and the number of interruptions in care because of CVIP. A multivariate mixed effects logistic regression was fitted for analytic analysis. We studied 1329 relays (Phase 1: 681, Phase 2: 648) from 133 patients (Phase 1: 63, Phase 2: 70). Incidents related to CVIP decreased from 137 (20%) in Phase 1 to 73 (11%) in Phase 2 (Ppumps in limiting the frequency of haemodynamic incidents related to relays and in reducing the nursing workload.

  8. Infusion pumps and red blood cell damage in transfusion therapy: an integrative revision of the academic literature

    Directory of Open Access Journals (Sweden)

    Ana Maria Miranda Martins Wilson

    Full Text Available ABSTRACT Objectives: to obtain information from scientific literature concerning infusion pumps used in administering erythrocyte (red blood cells and to evaluate the implications in the practical use of this equipment by nurses when conducting transfusions. Method: an integrative revision of the following scientific databases: Pubmed/Medline, Scopus, the Virtual Library for Health, SciELO, Web of Science and Cochrane. The following descriptors were used: "infusion pumps", "blood transfusion", "transfused erythrocyte" and "hemolyis". There were no restrictions on the scope of the initial data and it was finalized in December 2014. 17 articles were identified in accordance with the inclusion and exclusion criteria. Results: all of the publications included in the studies were experimental in vitro and covered the use of infusion pumps in transfusion therapy. A summary of the data was presented in a synoptic chart and an analysis of it generated the following categories: cellular damage and the infusion mechanism. Conclusion: infusion pumps can be harmful to erythrocytes based on the infusion mechanism that is used, as the linear peristaltic pump is more likely to cause hemolysis. Cellular damage is related to the plasmatic liberation of markers that largely dominate free hemoglobin and potassium. We reiterate the need for further research and technological investments to guide the development of protocols that promote safe practices and that can contribute to future clinical studies.

  9. Continuous subcutaneous delivery of medications for home care palliative patients-using an infusion set or a pump?

    Science.gov (United States)

    Menahem, Sasson; Shvartzman, Pesach

    2010-09-01

    The purpose of this study was to evaluate safety, feasibility, and efficacy of continuous drug delivery by the subcutaneous route through a solution bag connected to an infusion set compared with an infusion pump in a home palliative care setting. Patients in need of continuous subcutaneous medication delivery for pain control, nausea, and/or vomiting were recruited. The study was designed as a double-blind, crossover study. The patient was connected to two parallel subcutaneous lines running simultaneously, connected together to a line entering the subcutaneous tissue. One line is connected to an infusion set and the other to a pump. The infusion set included a 500-cc solution bag connected to a 1.5-m plastic tube containing a drip chamber controlled by a roller clamp that is gravity driven without hyaluronidase. Active medications were randomly assigned to start in either administration method and switched after 24 h. An independent research assistant evaluated symptom control and side effects at baseline and every 24 h for 2 days using a structured questionnaire. Another independent research assistant connected the lines after adding medications and evaluated technical and clinical failures. Twenty-seven patients were recruited, and of them, 18 completed the study. Incidents in fluid administration were more common through the infusion set (18 times) compared to the pump (only twice). On the other hand, no clinical significant change was noted in the average symptom levels and side effects when medications were given through the infusion set versus the pump. No local edema or irritation was observed in either way of administration. In a home palliative care setting with a medical staff on call for 24 h, using medications for symptom control can be considered to be infused to a fluid solution bag through an infusion set instead of using a syringe driver or a pump when there is a responsible caregiver to follow up on the fluid. Subcutaneous constant drug delivery

  10. Catheter Migration After Implantationan Intrathecal Baclofen Infusion Pump for Severe Spasticity: A Case Report

    Directory of Open Access Journals (Sweden)

    Tung-Chou Li

    2008-09-01

    Full Text Available We report a case of intrathecal baclofen infusion pump implantation complicated by migration of the catheter tip. A 55-year-old man required an intrathecal baclofen infusion for severe spasticity 4 years after a cervical spinal cord injury with incomplete tetraparesis. Twelve months after initial implantation of the device, the patient began to experience a recurrence of trunk tightness and spasticity. Subsequent X-ray and computed tomography evaluations of the catheter system revealed pooling of contrast medium outside of the intrathecal distribution in the lumbar subcutaneous region of the back and therefore migration of the pump catheter tip. At surgical revision, emphasis was placed on minimizing the length of catheter outside of the spine and securing the catheter in the supraspinous fascia with a right-angled anchor. The distance between the anchors and the entry point of the catheter into the supraspinous fascia was also reduced to prevent slipping when the patient bends forward. After surgery, the patient's spasticity improved and, 1 year later, he has experienced no further complications during follow-up, requiring an average baclofen dose of 150 mg/day. Here, we describe several surgical methods intended to secure the intrathecal catheter and prevent catheter migration. Other complications related to catheter failure are also highlighted.

  11. Test and Evaluation Report of the IMED Volumetric Infusion Pump Model 960A

    Science.gov (United States)

    1992-02-01

    tested Ambient tempera- ture was out of test lim- its. Windshield anti-ice X Pitot heat X Vent blower X Windshield wiper X Heater X APU X Generator #1 X...Patterson John A. Dellinger, Air Force Base, OH 45433 Southwest Research Institute P. 0. Box 28510 Henry L. Taylor San Antonio, TX 78284 Director

  12. Comparison between Infusion Pumps: Fentanyl/Ketamine and Fentanyl/Paracetamol in Pain control Following Tight and Leg Surgeries

    Directory of Open Access Journals (Sweden)

    Behnam Mahmoodiyeh

    2016-08-01

    Full Text Available Background: Adjuvants such as ketamine, promethazine and paracetamol could bring up patients satisfaction and control harmful effects of opioids besides lessening their needed doses, as seen by fentanyl/paracetamol and fentanyl/ketamine combination before. The current study headed to compare paracetamol and ketamine in addition to fentanyl applied by infusion pumps in order to pain relief following major surgery.Methods: Through a double blinded randomized clinical trial, patients between18 and 65 with elective surgery for tight or leg fractures with ASA Class 1 and 2 referring to a university hospital in Arak, a town in central region of Iran, were recruited and used infusion pump for their postoperative pain control. The participants were divided into cases and controls regarding using ketamine/fentanyl (KF or paracetamol/fentanyl (PF infusion pumps.Results: The mean pain score was totally 3.87 with higher value in KF (5.06 and lower in PF (4.5 immediately after finishing surgery and getting conscious when started using infusion pump. There was no statistical difference between the groups in this regard. Concerning the side effects of the applied medications, blood pressure and heart rate had no differences comparing the groups.Conclusion: This study showed that paracetamol used in infusion pump can be brilliant in pain control after major surgeries like what done in lower extremities and joint replacement while lessens opioid use. Although paracetamol was more effective than ketamine in the current trial, more qualified studies at bigger size and in other fields of surgery beside orthopedic ones would be useful to support the effects if applicable.Keywords: Infusion pump, Ketamine, Paracetamol, Fentanyl, Postoperative pain

  13. Effects of atmospheric pressure conditions on flow rate of an elastomeric infusion pump.

    Science.gov (United States)

    Wang, Jong; Moeller, Anna; Ding, Yuanpang Samuel

    2012-04-01

    The effects of pressure conditions, both hyperbaric and hypobaric, on the flow rate of an elastomeric infusion pump were investigated. The altered pressure conditions were tested with the restrictor outlet at two different conditions: (1) at the same pressure condition as the Infusor elastomeric balloon and (2) with the outlet exposed to ambient conditions. Five different pressure conditions were tested. These included ambient pressure (98-101 kilopascals [kPa]) and test pressures controlled to be 10 or 20 kPa below or 75 or 150 kPa above the ambient pressure. A theoretical calculation based on the principles of fluid mechanics was also used to predict the pump's flow rate at various ambient conditions. The conditions in which the Infusor elastomeric pump and restrictor outlet were at the same pressure gave rise to average flow rates within the ±10% tolerance of the calculated target flow rate of 11 mL/hr. The flow rate of the Infusor pump decreased when the pressure conditions changed from hypobaric to ambient. The flow rate increased when the pressure conditions changed from hyperbaric to ambient. The flow rate of the Infusor elastomeric pump was not affected when the balloon reservoir and restrictor outlet were at the same pressure. The flow rate varied from 58.54% to 377.04% of the labeled flow rate when the pressure applied to the reservoir varied from 20 kPa below to 150 kPa above the pressure applied to the restrictor outlet, respectively. The maximum difference between observed flow rates and those calculated by applying fluid mechanics was 4.9%.

  14. Combining situated Cognitive Engineering with a novel testing method in a case study comparing two infusion pump interfaces

    NARCIS (Netherlands)

    Schnittker, R.; Schmettow, M.; Verhoeven, F.; Schraagen, J.M.C.

    2016-01-01

    We validated the usability of a new infusion pump interface designed with a situated Cognitive Engineering approach by comparing it to a reference interface using a novel testing method employing repeated measurements and process measures, in addition to traditional outcome measures. The sample

  15. Methods for studying medical device technology and practitioner cognition : The case of user-interface issues with infusion pumps

    NARCIS (Netherlands)

    Schraagen, J.M.C.; Verhoeven, F.

    2013-01-01

    Purpose : The aims of this study were to investigate how a variety of research methods is commonly employed to study technology and practitioner cognition. User-interface issues with infusion pumps were selected as a case because of its relevance to patient safety. Methods : Starting from a

  16. The development and evaluation of a subcutaneous infusion delivery system based on osmotic pump control and gas drive.

    Science.gov (United States)

    Xie, Xiangyang; Yang, Yang; Yang, Yanfang; Li, Zhiping; Zhang, Hui; Chi, Qiang; Cai, Xingshi; Mei, Xingguo

    2016-09-01

    A novel, self-administration drug delivery system for subcutaneous infusion was developed and evaluated. The device includes two main components: an osmotic tablet controlled gas actuator and a syringe catheter system. The sodium carbonate in the osmotic pump tablet will release into the surround citric acid solution and produce CO 2 gas, which will drive the drug solution into subcutaneous tissue. The key formulation factors of the osmotic tablet that would influence the infusion profiles of the device were investigated by single factor exploration. The formulation was optimized via a response surface methodology. With an 18 ± 4 min of lag time, the delivery system was able to infuse at an approximate zero-order up to 5.90 ± 0.37 h with a precision of 9.0% RSD (n = 6). A linear correlation was found for the infusion profile and the fitting equation was Y = 0.014X - 0.004 (r = 0.998). A temperature change of 4 °C was found to modify the flow rate by about 12.0%. In vivo results demonstrated that the present subcutaneous infusion device was similar to the commercial infusion pump, and it could bring a long and constant ampicillin plasma level with minimized fluctuations.

  17. Electromagnetically controlled measuring device for measuring injection quantities in a diesel injection pump volumetrically. Elektromagnetisch gesteuerte Messvorrichtung zur volumetrischen Messung von Einspritzmengen einer Dieseleinspritzpumpe

    Energy Technology Data Exchange (ETDEWEB)

    Hoffmann, K H; Mueller, M; Decker, R; Huber, G

    1990-11-22

    The invention concerns a measuring device for volumetric measurements of injection quantities of a diesel injection pump which injects its contents into a volumetric chamber controlled electromagnetically by a discharge valve and enclosed by a non-impact gas pressure loaded volumetric vessel and effects a retreating movement of the latter. The device is provided with an inductive path controller fitted with a differential pair of coils containing an axially movable ferromagnetic core. The path controller forms a part of a lifter rod connected to the volumetric vessel. It gives an opening signal to the discharge valve after each retreat of the volumetric vessel and a closing signal as soon as a defined height of suspension corresponding to the original position of the volumetric vessel after its return is reached.

  18. Methods for studying medical device technology and practitioner cognition: the case of user-interface issues with infusion pumps.

    Science.gov (United States)

    Schraagen, Jan Maarten; Verhoeven, Fenne

    2013-02-01

    The aims of this study were to investigate how a variety of research methods is commonly employed to study technology and practitioner cognition. User-interface issues with infusion pumps were selected as a case because of its relevance to patient safety. Starting from a Cognitive Systems Engineering perspective, we developed an Impact Flow Diagram showing the relationship of computer technology, cognition, practitioner behavior, and system failure in the area of medical infusion devices. We subsequently conducted a systematic literature review on user-interface issues with infusion pumps, categorized the studies in terms of methods employed, and noted the usability problems found with particular methods. Next, we assigned usability problems and related methods to the levels in the Impact Flow Diagram. Most study methods used to find user interface issues with infusion pumps focused on observable behavior rather than on how artifacts shape cognition and collaboration. A concerted and theory-driven application of these methods when testing infusion pumps is lacking in the literature. Detailed analysis of one case study provided an illustration of how to apply the Impact Flow Diagram, as well as how the scope of analysis may be broadened to include organizational and regulatory factors. Research methods to uncover use problems with technology may be used in many ways, with many different foci. We advocate the adoption of an Impact Flow Diagram perspective rather than merely focusing on usability issues in isolation. Truly advancing patient safety requires the systematic adoption of a systems perspective viewing people and technology as an ensemble, also in the design of medical device technology. Copyright © 2012 Elsevier Inc. All rights reserved.

  19. Radical resection for low rectal carcinoma combined with infusion pump chemotherapy via internal iliac artery

    Directory of Open Access Journals (Sweden)

    Bo YANG

    2011-10-01

    Full Text Available Objective To evaluate the effects and practicability of radical resection for low rectal carcinoma with infusion pump chemotherapy via internal iliac artery,and explore the correlation factors influencing the therapeutic effects.Methods Data of 316 patients with low rectal carcinoma,admitted from Oct.1997 to Mar.2008,were retrospectively analyzed and assigned into 2 groups according to the treatment: Patients received infusion pump chemotherapy via internal iliac artery to target area combined with intravenous systemic chemotherapy were assigned into group A(n=249,and those receiving systemic chemotherapy alone following radical resection were assigned to group B(n=67.The timing of pump chemotherapy to target area in group A was set at day 12 after recovery of digestive function,with regimen of 5-FU at 0.5g per dose plus hydroxycamptothecin at 10-15mg per dose,twice a week,four times as a treatment course for a total of 6 courses,and it was followed by intravenously systemic chemotherapy with a regimen of FOLFIRI or FOLFOX.In group B,at day 12 right after recovery of digestive function,the intravenous sytemic chemotherapy was started with the same regimen as in group A.The local recurrence rate,metastasis rate and survival rate after 1,3 and 5 years in the two groups were respectively observed and compared,and the correlation between the clinicopathological features and the 5 year local recurrence rates and survival rates was analyzed in patients of group A.Results In group A,the local recurrence rate at year 1,3 and 5 was 0,1.68%(4/238 and 3.79%(8/211,respectively,the metastasis rate was 0.80%(2/249,4.62%(11/238 and 10.90%(23/211,respectively,and the survival rate was 100%,77.73%(185/238 and 72.04%(152/211,respectively.In group B,the local recurrence rate at year 1,3 and 5 was 0,9.52%(6/63 and 16.36%(9/55,respectively,the metastasis rate was 1.49%(1/67,15.87%(10/63 and 27.27%(15/55,respectively,and the survival rate was 100

  20. Home Healthcare Medical Devices: Infusion Therapy - Getting the Most Out of Your Pump

    Science.gov (United States)

    ... Medical Procedures Home Health and Consumer Devices Brochure - Home Healthcare Medical Devices: Infusion Therapy - Getting the Most ... if needed. What is the role of your home healthcare provider and supplier in your infusion therapy? ...

  1. The efficacy of a lidocaine-infused pain pump for postoperative analgesia following elective augmentation mammaplasty or abdominoplasty.

    Science.gov (United States)

    Chavez-Abraham, Victor; Barr, Jason S; Zwiebel, Paul C

    2011-08-01

    Postoperative pain management following aesthetic plastic surgery traditionally has been achieved by systemic administration of several narcotic pain medications. Because this method can lead to undesirable side effects such as sedation, nausea, vomiting, and respiratory depression, a more efficacious method of postoperative analgesia with fewer side effects needs to be implemented in outpatient cosmetic surgery. From March of 2003 until December of 2008, 690 patients underwent augmentation mammaplasty and 215 patients underwent abdominoplasty. All of these patients were equipped with an elastomeric continuous infusion pump postoperatively and were prescribed oral narcotics. Prior to 2003, patients were prescribed only oral narcotics postoperatively. A retrospective chart review of patients before and after implementation of the pain pump was undertaken to review the perceived pain patients experienced postoperatively with and without the pump. The self-administration of oral narcotics was also assessed. Patients equipped with the pain pump experienced a statistically significant decrease in perceived pain compared to those without the pump (augmentation mammaplasty: 2.27 vs. 3.68, p use of the oral narcotic Vicodin™ at 72 h postoperatively (5 mg hydrocodone/500 mg acetaminophen, Abbott Laboratories, Abbott Park, IL) (augmentation mammaplasty: 26.5 mg/2650 mg vs. 49 mg/4900 mg, p reduce both the amount of pain patients experience and the quantity of narcotics used postoperatively.

  2. Infusion pumps and red blood cell damage in transfusion therapy: an integrative revision of the academic literature.

    Science.gov (United States)

    Wilson, Ana Maria Miranda Martins; Peterlini, Maria Angélica Sorgini; Pedreira, Mavilde da Luz Gonçalves

    2016-08-15

    to obtain information from scientific literature concerning infusion pumps used in administering erythrocyte (red blood cells) and to evaluate the implications in the practical use of this equipment by nurses when conducting transfusions. an integrative revision of the following scientific databases: Pubmed/Medline, Scopus, the Virtual Library for Health, SciELO, Web of Science and Cochrane. The following descriptors were used: "infusion pumps", "blood transfusion", "transfused erythrocyte" and "hemolyis". There were no restrictions on the scope of the initial data and it was finalized in December 2014. 17 articles were identified in accordance with the inclusion and exclusion criteria. all of the publications included in the studies were experimental in vitro and covered the use of infusion pumps in transfusion therapy. A summary of the data was presented in a synoptic chart and an analysis of it generated the following categories: cellular damage and the infusion mechanism. infusion pumps can be harmful to erythrocytes based on the infusion mechanism that is used, as the linear peristaltic pump is more likely to cause hemolysis. Cellular damage is related to the plasmatic liberation of markers that largely dominate free hemoglobin and potassium. We reiterate the need for further research and technological investments to guide the development of protocols that promote safe practices and that can contribute to future clinical studies. identificar na literatura a produção científica acerca dos efeitos de bomba de infusão na administração de hemácias e avaliar as implicações do uso desses equipamentos na prática transfusional de enfermagem. revisão integrativa de literatura nas bases de dados Pubmed/Medline, Scopus, Biblioteca Virtual em Saúde, SciELO, Web of Science e Cochrane, utilizando os descritores "bombas de infusão", "transfusão de sangue", "transfusão de eritrócitos" e "hemólise". A data inicial não foi delimitada e a final foi dezembro de

  3. Protocol for a randomised crossover trial to evaluate patient and nurse satisfaction with electronic and elastomeric portable infusion pumps for the continuous administration of antibiotic therapy in the home: the Comparing Home Infusion Devices (CHID) study.

    Science.gov (United States)

    Hobbs, Jodie G; Ryan, Melissa K; Ritchie, Brett; Sluggett, Janet K; Sluggett, Andrew J; Ralton, Lucy; Reynolds, Karen J

    2017-07-31

    Previous studies comparing satisfaction with electronic and elastomeric infusion pumps are limited, and improvements in size and usability of electronic pumps have since occurred. The Comparing Home Infusion Devices (CHID) study plans to assess patient and nurse satisfaction with an elastomeric and electronic pump for delivering intravenous antibiotic treatment in the home. Secondary objectives are to determine pump-related complications and actual antibiotic dose administered, evaluate temperature variation and compare pump operating costs. The CHID study will be a randomised, crossover trial. A trained research nurse will recruit patients with infectious disease aged ≥18 years and prescribed ≥8 days of continuous intravenous antibiotic therapy from the Royal Adelaide Hospital (RAH) (Adelaide, Australia). Patients will be randomised to receive treatment at home via an elastomeric (Baxter Infusor) or an electronic (ambIT Continuous) infusion pump for 4-7 days, followed by the other for a further 4-7 days. Patient satisfaction will be assessed by a 10-item survey to be completed at the end of each arm. Nurse satisfaction will be assessed by a single 24-item survey. Patient logbooks and case notes from clinic visits will be screened to identify complications. Pumps/infusion bags will be weighed to estimate the volume of solution delivered. Temperature sensors will record skin and ambient temperatures during storage and use of the pumps throughout the infusion period. Costs relating to pumps, consumables, antibiotics and servicing will be determined. Descriptive statistics will summarise study data. This study has been approved by the RAH Human Research Ethics Committee (HREC/16/RAH/133 R20160420, version 6.0, 5 September 2016). Study results will be disseminated through peer-reviewed publications and conference presentations. The CHID study will provide key insights into patient and provider satisfaction with elastomeric and electronic infusion pumps and inform

  4. Designing the modern pump: engineering aspects of continuous subcutaneous insulin infusion software.

    Science.gov (United States)

    Welsh, John B; Vargas, Steven; Williams, Gary; Moberg, Sheldon

    2010-06-01

    Insulin delivery systems attracted the efforts of biological, mechanical, electrical, and software engineers well before they were commercially viable. The introduction of the first commercial insulin pump in 1983 represents an enduring milestone in the history of diabetes management. Since then, pumps have become much more than motorized syringes and have assumed a central role in diabetes management by housing data on insulin delivery and glucose readings, assisting in bolus estimation, and interfacing smoothly with humans and compatible devices. Ensuring the integrity of the embedded software that controls these devices is critical to patient safety and regulatory compliance. As pumps and related devices evolve, software engineers will face challenges and opportunities in designing pumps that are safe, reliable, and feature-rich. The pumps and related systems must also satisfy end users, healthcare providers, and regulatory authorities. In particular, pumps that are combined with glucose sensors and appropriate algorithms will provide the basis for increasingly safe and precise automated insulin delivery-essential steps to developing a fully closed-loop system.

  5. A web-based study of the relationship of duration of insulin pump infusion set use and fasting blood glucose level in adults with type 1 diabetes.

    Science.gov (United States)

    Sampson Perrin, Alysa J; Guzzetta, Russell C; Miller, Kellee M; Foster, Nicole C; Lee, Anna; Lee, Joyce M; Block, Jennifer M; Beck, Roy W

    2015-05-01

    To evaluate the impact of infusion set use duration on glycemic control, we conducted an Internet-based study using the T1D Exchange's online patient community, Glu ( myGlu.org ). For 14 days, 243 electronically consented adults with type 1 diabetes (T1D) entered online that day's fasting blood glucose (FBG) level, the prior day's total daily insulin (TDI) dose, and whether the infusion set was changed. Mean duration of infusion set use was 3.0 days. Mean FBG level was higher with each successive day of infusion set use, increasing from 126 mg/dL on Day 1 to 133 mg/dL on Day 3 to 147 mg/dL on Day 5 (P<0.001). TDI dose did not vary with increased duration of infusion set use. Internet-based data collection was used to rapidly conduct the study at low cost. The results indicate that FBG levels increase with each additional day of insulin pump infusion set use.

  6. [The use of continuous subcutaneous insulin infusion (CSII) with personal insulin pumps in the treatment of children and adolescents with diabetes type 1].

    Science.gov (United States)

    Jarosz-Chobot, Przemysława

    2004-01-01

    This paper sums up recently published researches on the continuous subcutaneous insulin infusion (CSII) with the use of insulin pump in children and adolescents with diabetes type 1. Obtaining a balance in the organism metabolism in childhood and adolescence diabetology is nowadays one of the most important rules of the diabetes management in children. One of the modern ways to achieve that goal is the intensive insulin therapy model with use of the insulin pump. In this paper the advantages and disadvantages as well as the indications and contraindications for the CSII in children and adolescents with diabetes are widely discussed.

  7. Effect of continuous subcutaneous insulin pump infusion on glucolipid metabolism as well as inflammation and oxidative stress in placenta of patients with GDM

    Directory of Open Access Journals (Sweden)

    Liu Jie

    2017-05-01

    Full Text Available Objective: To study the effect of continuous subcutaneous insulin pump infusion on glucolipid metabolism as well as inflammation and oxidative stress in placenta of patients with gestational diabetes mellitus (GDM. Methods: Patients with GDM who received insulin therapy between March 2013 and May 2016 were selected as the research subjects and randomly divided into multiple subcutaneous insulin injection (MSII group and continuous subcutaneous insulin pump infusion (CSII group. Before and after treatment, serum glucolipid metabolism as well as inflammation and oxidative stress inexes in placenta were determined respectively. Results: 2 weeks and 4 weeks after treatment, FBG, 1hPBG, 2hPBG, Chemerin, Vaspin and Visfatin levels of both groups of patients were significantly lower than those before treatment and FBG, 1hPBG, 2hPBG, Chemerin, Vaspin and Visfatin levels of CSII group were significantly lower than those of MSII group; after delivery, TNF-α, IL-6, ROS and AGEs levels in placenta of CSII group were significantly lower than those of MSII group. Conclusion: Continuous subcutaneous insulin infusion can more effectively improve the glucolipid metabolism and inhibit the inflammation and oxidative stress in placenta of patients with GDM than multiple subcutaneous insulin injection.

  8. Effect of different dosages of nitroglycerin infusion on arterial blood gas tensions in patients undergoing on- pump coronary artery bypass graft surgery.

    Science.gov (United States)

    Masoumi, Gholamreza; Pour, Evaz Hidar; Sadeghpour, Ali; Ziayeefard, Mohsen; Alavi, Mostapha; Anbardan, Sanam Javid; Shirani, Shahin

    2012-02-01

    On-pump coronary artery bypass graft (CABG) surgery impairs gas exchange in the early postoperative period. The main object on this study was evaluation of changes in arterial blood gas values in patients underwent on pump CABG surgery receiving different dose of intravenous nitroglycerin (NTG). sixty-seven consecutive patients undergoing elective on-pump CABG randomly enrolled into three groups receiving NTG 50 μg/min (Group N1, n =67), 100 μg/min (Group N2, n = 67), and 150 μg/min (Group N3, n = 67). Arterial blood gas (ABG) tensions were evaluated just before induction of anesthesia, during anesthesia, at the end of warming up period, and 6 h after admission to the intensive care unit. Pao2 and PH had the highest value during surgery in Group N1, Group N2, and Group N3. No significant difference was noted in mean values of Pao2 and PH during surgery between three groups (P > 0.05). There was no significant difference in HCO3 values in different time intervals among three groups (P > 0.05). our results showed that infusing three different dosage of NTG (50, 100, and 150 μg/min) had no significant effect on ABG tensions in patients underwent on-pump CABG surgery.

  9. Bomba de infusão de insulina em diabetes melito tipo 1 Insulin pump therapy in type 1 diabetes mellitus

    Directory of Open Access Journals (Sweden)

    Raphael Del Roio Liberatore Jr.

    2006-08-01

    Full Text Available OBJETIVO: Rever a experiência com a utilização da bomba de infusão de insulina em crianças e adolescentes, a fim de orientar o pediatra quanto às suas indicações e complicações. FONTE DOS DADOS : Foi realizada revisão sistemática de artigos publicados em literatura que abordassem a utilização da bomba de infusão de insulina, suas indicações, complicações e resposta ao tratamento. Dessa forma, todos os artigos publicados entre 1995 e 2005 foram resgatados através do levantamento em banco de dados MEDLINE e LILACS. As palavras-chave utilizadas foram: insulin pumps, type 1 diabetes mellitus e diabetes mellitus. Foram separados os artigos que, além disso, versassem sobre o assunto na faixa etária descrita SÍNTESE DOS DADOS: O uso da bomba de infusão de insulina em pacientes com diabetes melito tipo 1 não é uma necessidade para todos os pacientes, visto que, com tratamentos intensivos, os resultados conseguidos são muito parecidos, em termos de hemoglobina glicada e de controle de complicações a médio e longo prazo. No entanto, a bomba permite um maior conforto ao paciente, no sentido de que ele não precisa ficar tão restrito a horários rígidos de refeição e pode levar uma vida com melhor qualidade. Um primeiro requisito para quem pretenda usar a bomba é adaptar-se a aparelhos conectados ao corpo e a ter uma rotina de monitorização glicêmica rigorosa, pois, sem isso, as vantagens da bomba serão anuladas. As complicações, com os avanços tecnológicos de que dispomos atualmente, são muito infreqüentes. O custo, no entanto, é maior que nos tratamentos convencionais. CONCLUSÃO: Com a evolução das bombas de infusão e dos monitores de glicemia, incluindo sistemas de monitorização contínua, abre-se caminho para as "bombas inteligentes", e estaremos com um verdadeiro "pâncreas artificial", que pode mesmo ser implantado no paciente, permitindo uma vida com todas as regalias de uma pessoa não diab

  10. PUMPS

    Science.gov (United States)

    Thornton, J.D.

    1959-03-24

    A pump is described for conveving liquids, particure it is not advisable he apparatus. The to be submerged in the liquid to be pumped, a conduit extending from the high-velocity nozzle of the injector,and means for applying a pulsating prcesure to the surface of the liquid in the conduit, whereby the surface oscillates between positions in the conduit. During the positive half- cycle of an applied pulse liquid is forced through the high velocity nozzle or jet of the injector and operates in the manner of the well known water injector and pumps liquid from the main intake to the outlet of the injector. During the negative half-cycle of the pulse liquid flows in reverse through the jet but no reverse pumping action takes place.

  11. In-depth interviews of patients with primary immunodeficiency who have experienced pump and rapid push subcutaneous infusions of immunoglobulins reveal new insights on their preference and expectations.

    Science.gov (United States)

    Cozon, Grégoire Jacques Noël; Clerson, Pierre; Dokhan, Annaïk; Fardini, Yann; Sala, Taylor Pindi; Crave, Jean-Charles

    2018-01-01

    Patients with primary immunodeficiency (PID) often receive immunoglobulin replacement therapy (IgRT). Physicians and patients have the choice between various methods of administration. For subcutaneous immunoglobulin infusions, patients may use an automated pump (P) or push the plunger of a syringe (rapid push [RP]). P infusions are performed once a week and last around 1 hour. RP decreases the duration of administration, but requires more frequent infusions. Eight out of 30 patients (coming from a single center) who had participated in the cross-over, randomized, open-label trial comparing P and RP participated in a focus group or underwent in-depth interviews. Patients had a long history of home-based subcutaneous immunoglobulin using P. The trial suggested that RP had slightly greater interference on daily life than P, but similar efficacy and better cost-effectiveness. When asked about the delivery method they had preferred, around one-third of patients pointed out RP rather than P. In-depth interviews may reveal unforeseen reasons for patients' preferences. Interviews underlined the complexity of the relationship that the patients maintain with their disease and IgRT. Even if they recognized the genetic nature of the disease and claimed PID was a part of them, patients tried not to be overwhelmed by the disease. IgRT by P was well integrated in patients' routine. By contrast, RP too frequently reminded the patients of their disease. In addition, some patients pointed out the difficulty of pushing the plunger due to the viscosity of the product. Coming back too frequently, RP was not perceived as time saving over a week. Long-lasting use of P could partly explain patients' reasonable reluctance to change to RP. In-depth interviews of PID patients highlighted unforeseen reasons for patients' preference that the physician needs to explore during the shared medical decision-making process.

  12. In-depth interviews of patients with primary immunodeficiency who have experienced pump and rapid push subcutaneous infusions of immunoglobulins reveal new insights on their preference and expectations

    Directory of Open Access Journals (Sweden)

    Cozon GJN

    2018-03-01

    Full Text Available Grégoire Jacques Noël Cozon,1 Pierre Clerson,2 Annaïk Dokhan,3 Yann Fardini,2 Taylor Pindi Sala,4 Jean-Charles Crave4 1Department of Clinical Immunology and Rheumatology, Edouard Herriot Hospital, Lyon, France; 2Soladis Clinical Studies, Roubaix, France; 3KPL, Paris, France; 4Octapharma France, Boulogne, France Purpose: Patients with primary immunodeficiency (PID often receive immunoglobulin replacement therapy (IgRT. Physicians and patients have the choice between various methods of administration. For subcutaneous immunoglobulin infusions, patients may use an automated pump (P or push the plunger of a syringe (rapid push [RP]. P infusions are performed once a week and last around 1 hour. RP decreases the duration of administration, but requires more frequent infusions.Patients and methods: Eight out of 30 patients (coming from a single center who had participated in the cross-over, randomized, open-label trial comparing P and RP participated in a focus group or underwent in-depth interviews. Patients had a long history of home-based subcutaneous immunoglobulin using P. The trial suggested that RP had slightly greater interference on daily life than P, but similar efficacy and better cost-effectiveness. When asked about the delivery method they had preferred, around one-third of patients pointed out RP rather than P. In-depth interviews may reveal unforeseen reasons for patients’ preferences. Results: Interviews underlined the complexity of the relationship that the patients maintain with their disease and IgRT. Even if they recognized the genetic nature of the disease and claimed PID was a part of them, patients tried not to be overwhelmed by the disease. IgRT by P was well integrated in patients’ routine. By contrast, RP too frequently reminded the patients of their disease. In addition, some patients pointed out the difficulty of pushing the plunger due to the viscosity of the product. Coming back too frequently, RP was not perceived

  13. Treatment of idiopathic hypogonadotropic hypogonadism in men with luteinizing hormone-releasing hormone: a comparison of treatment with daily injections and with the pulsatile infusion pump.

    Science.gov (United States)

    Shargil, A A

    1987-03-01

    Thirty husbands in childless couples, aged 24 to 35 years, were treated with luteinizing hormone-releasing hormone (LH-RH) for idiopathic hypogonadotropic hypogonadism (IHH) of peripubertal (incomplete) type. They were azoospermic or oligospermic, with less than 1.5 X 10(6)/ml nonmotile spermatozoa. The diagnosis of IHH was based on clinical and laboratory features and testicular biopsy specimen study and was further supported by results of stimulation tests and gonadotropin-releasing hormone (GnRH) test. Two treatment modalities were used: subcutaneous injections of 500 micrograms LH-RH twice daily; and perpetual subcutaneous injection, via portable infusion pump, of 25 ng/kg LH-RH, at 90-minute intervals. Two patients required a short second period of pulsatile treatment to cause a second pregnancy of their spouses. The pump proved to yield better results, compared with intermittent injections, in respect to endocrine responses, spermatogenesis, and fertility capacity. Normal levels of luteinizing hormone and follicle-stimulating hormone were reached in 2 to 3 weeks and normal testosterone levels in 8 to 10 weeks from the start of treatment. Sperm counts rose to greater than 60 X 10(6)/ml viable spermatozoa with less than 15% of abnormal forms in 3 to 5 months, and the wives conceived. Of a total of 18 deliveries of healthy infants, 12 offspring were identified genetically with their fathers. Four women were still pregnant at the conclusion of the study. The pump was well tolerated, without special operational problems to the patients. Pulsatile treatment is therefore recommended in the treatment of well-diagnosed and carefully selected cases of incomplete IHH.

  14. Prophylactic furosemide infusion decreasing early major postoperative renal dysfunction in on-pump adult cardiac surgery: a randomized clinical trial

    Directory of Open Access Journals (Sweden)

    Fakhari S

    2017-01-01

    Full Text Available Solmaz Fakhari,1 Fariba Mirzaei Bavil,2 Eissa Bilehjani,1 Sona Abolhasani,3 Moussa Mirinazhad,2 Bahman Naghipour2 1Department of Anesthesiology, 2Department of Physiology, 3Tabriz University of Medical Sciences, Tabriz, Iran Introduction: Acute renal dysfunction is a common complication of cardiac surgery. Furosemide is used in prevention, or treatment, of acute renal dysfunction. This study was conducted to evaluate the protective effects of intra- and early postoperative furosemide infusion on preventing acute renal dysfunction in elective adult cardiac surgery. Methods: Eighty-one patients, candidates of elective cardiac surgery, were enrolled in this study in either the furosemide (n=41 or placebo (n=40 group. Furosemide (2 mg/h or 0.9% saline was administered and continued up to 12 hours postoperatively. We measured serum creatinine (Scr at preoperative and on the second and fifth postoperative days. Then calculated estimated glomerular filtration rate (eGFR at these times. An increase in Scr of >0.5 mg/dL and/or >25%–50%, compared to preoperative values, was considered as acute kidney injury (AKI. In contrast, an increase in Scr by >50% and/or the need for hemodialysis was regarded as acute renal failure (ARF. At the end we compared the AKI or ARF incidence between the two groups. Results: On the second and fifth postoperative days, Scr was lower, and the eGFR was higher in the furosemide group. AKI incidence was similar in the two groups (11 vs 12 cases; P-value 0.622; however, ARF rate was lower in furosemide group (1 vs 6 cases; P-value 0.044. During the study period, Scr was more stable in the furosemide group, however in the placebo group, Scr initially increased and then decreased to its preoperative value after a few days. Conclusion: This study showed that intra- and early postoperative furosemide infusion has a renal protective effect in adult cardiac surgery with cardiopulmonary bypass. Although this protective effect cannot

  15. Pump

    International Nuclear Information System (INIS)

    Mole, C.J.

    1983-01-01

    An electromagnetic pump for circulating liquid -metal coolant through a nuclear reactor wherein opposite walls of a pump duct serve as electrodes to transmit current radially through the liquid-metal in the ducts. A circumferential electric field is supplied to the liquid-metal by a toroidal electromagnet which has core sections interposed between the ducts. The windings of the electromagnet are composed of metal which is superconductive at low temperatures and the electromagnet is maintained at a temperature at which it is superconductive by liquid helium which is fed through the conductors which supply the excitation for the electromagnet. The walls of the ducts joining the electrodes include metal plates insulated from the electrodes backed up by insulators so that they are capable of withstanding the pressure of the liquid-metal. These composite wall structures may also be of thin metal strips of low electrical conductivity backed up by sturdy insulators. (author)

  16. Skin regeneration in deep second-degree scald injuries either by infusion pumping or topical application of recombinant human erythropoietin gel

    Directory of Open Access Journals (Sweden)

    Giri P

    2015-05-01

    Full Text Available Priya Giri,1 Sabine Ebert,1 Ulf-Dietrich Braumann,2 Mathias Kremer,3 Shibashish Giri,1 Hans-Günther Machens,4 Augustinus Bader1 1Department of Cell Techniques and Applied Stem Cell Biology, Center for Biotechnology and Biomedicine (BBZ, Faculty of Medicine, University of Leipzig, Leipzig, Germany; 2Interdisciplinary Center for Bioinformatics (IZBI, University of Leipzig, Leipzig, Germany; 3Department of Plastic and Hand Surgery, University of Lübeck, Lübeck, Germany; 4Department of Plastic and Hand Surgery, Technical University of Munich, Munich, Germany Abstract: Large doses of recombinant growth factors formulated in solution form directly injected into the body is usual clinical practice in treating second-degree scald injuries, with promising results, but this approach creates side effects; furthermore, it may not allow appropriate levels of the factor to be sensed by the target injured tissue/organ in the specific time frame, owing to complications arising from regeneration. In this research, two delivery methods (infusion pumping and local topical application were applied to deliver recombinant human erythropoietin (rHuEPO for skin regeneration. First, rHuEPO was given in deep second-degree scald injury sites in mice by infusion pump. Vascularization was remarkably higher in the rHuEPO pumping group than in controls. Second, local topical application of rHuEPO gel was given in deep second-degree scald injury sites in rats. Histological analysis showed that epithelialization rate was significantly higher in the rHuEPO gel-treated group than in controls. Immunohistochemical studies showed that the rHuEPO gel-treated group showed remarkably higher expression of skin regeneration makers than the control group. An accurate method for visualization and quantification of blood vessel networks in target areas has still not been developed up to this point, because of technical difficulties in detecting such thin blood vessels. A method which

  17. Infusion Extractor

    Science.gov (United States)

    Chang-Diaz, Franklin R.

    1988-01-01

    Apparatus and method of removing desirable constituents from an infusible material by infusion extraction, where a piston operating in a first chamber draws a solvent into the first chamber where it may be heated, and then moves the heated solvent into a second chamber containing the infusible material, and where infusion extraction takes place. The piston then moves the solvent containing the extract through a filter into the first chamber, leaving the extraction residue in the second chamber.

  18. Infusion cisternography

    International Nuclear Information System (INIS)

    Magnaes, B.; Rootwelt, K.; Sjaastad, O.

    1976-01-01

    A source of error in cerebrospinal fluid (CSF) infusion tests is leakage at the dural puncture site. The addition of a bolus of radionuclide to the infusion fluid was helpful in detecting the existence of leakage as shown by increased infusion pressure in six of eight patients studied with and without scintigraphic evidence of leakage. Comparison of CSF dynamics in 26 patients studied by infusion cisternography and conventional cisternography showed similar patterns, suggesting no alteration of CSF dynamics by the artificial CSF infusion. Combining the two tests, therefore, resulted in simple identification of the leakage and saved the patient time and discomfort

  19. Pump trials for charged liquids

    International Nuclear Information System (INIS)

    Moroni, J.C.; Niver, A.

    1964-01-01

    The pumps intended for the circulation of charged and radioactive liquids have particular qualities. The choice of such a pump has called for endurance tests with various types of equipment: a Goodyear volumetric screw pumps, and RICHIER, Klein and SCHABAVER centrifugal pumps. The latter, fitted with a special oakum, gave the best results. (authors) [fr

  20. A remotely operated, automated system for the infusion of shielded therapeutic radiopharmaceuticals

    International Nuclear Information System (INIS)

    Macfarlane, D.J.; Bartlett, M.; Bellen, J.; Peters, J.; Domagala, M.; Allison, R.

    1999-01-01

    Full text: A number of radiopharmaceuticals may soon emerge into mainstream clinical oncology for palliative and therapeutic treatment for a variety of malignancies. These agents are characterized by high linear energy transfer particulate emissions. Dispensing and administration of these therapies on a regular basis pose a substantial radiation burden to staff, from direct g-emissions and from Bremsstrahlung (braking) radiations. In an effort to implement the ALARA principle, a multidisciplinary team was given the brief to design a system which permitted: (1) safe, sterile transfer of a nominated quantity of radiopharmaceutical into a shielded reservoir compatible with the infusion pump; (2) remote variation of volume and administration rate upon command; (3) purging of delivery system following administration of dose; (4) monitoring of and communication with patient during infusion; (5) use of TGA-approved delivery system. The final design centred around an Abbott 'Lifecare 5000' volumetric dual-channel intravenous infusion pump and featured: microprocessor control with mutiline LCD prompting display; remote operation of keypad by pneumatic actuator; CCTV monitoring of patient, pump and physiological data; delivery of therapy dose from a shielded vial; flushing of therapy vial by 'back-priming'; and full array of safety alarms (air in line, occlusion, empty vial, etc). Further developments include audio communication with patient and remote physiological monitoring

  1. A comparison of two nuclear-medical techniques for effective renal plasma flow determination in rabbits: Radiation controlled infusion-pump and whole-body measurement according to Oberhausen

    International Nuclear Information System (INIS)

    Mayer-Wehrstein, R.

    1981-01-01

    Two nuclear techniques were investigated for determination of the effective renal plasma flow with J-131-Hippuran in rabbits: whole-body measurement according to Oberhausen and clearance determination with a radiation controlled feed back infusion pump. In the first method the clearance determination follows after a single injection of the testing substance in the decreasing phase of the blood level, in the second method a constant blood level of the testing substance is maintained. A technique was developed for the determination of the blood-tissue ratio by considering the values determined by the constant blood level. This way the exact clearance values were computet for the decreasing plasma level. Nineteen clearance determinations were performed in rabbits altogether. (orig.) [de

  2. Continuous infusion thermodilution for assessment of coronary flow: Theoretical background and in vitro validation

    NARCIS (Netherlands)

    Veer, van 't M.; Geven, M.C.F.; Rutten, M.C.M.; Horst, van der A.; Aarnoudse, W.H.; Pijls, N.H.J.; Vosse, van de F.N.

    2009-01-01

    Direct volumetric assessment of coronary flow during cardiac catheterization has not been available so far. In the current study continuous infusion thermodilution, a method based on continuous infusion of saline into a selective coronary artery is evaluated. Theoretically, volumetric flow can be

  3. Continuous infusion of chemotherapy: focus on 5-fluorouracil and fluorodeoxyuridine

    NARCIS (Netherlands)

    Poorter, R. L.; Bakker, P. J.; Veenhof, C. H.

    1998-01-01

    Continuous infusion of chemotherapy is one of the developments to try to improve the treatment of metastatic cancer. There is a sound theoretical rationale to deliver cytotoxic drugs as a continuous infusion. Furthermore, the development of reliable venous access devices and portable infusion pumps

  4. Medication and volume delivery by gravity-driven micro-drip intravenous infusion: potential variations during "wide-open" flow.

    Science.gov (United States)

    Pierce, Eric T; Kumar, Vikram; Zheng, Hui; Peterfreund, Robert A

    2013-03-01

    Gravity-driven micro-drip infusion sets allow control of medication dose delivery by adjusting drops per minute. When the roller clamp is fully open, flow in the drip chamber can be a continuous fluid column rather than discrete, countable, drops. We hypothesized that during this "wide-open" state, drug delivery becomes dependent on factors extrinsic to the micro-drip set and is therefore difficult to predict. We conducted laboratory experiments to characterize volume delivery under various clinically relevant conditions of wide-open flow in an in vitro laboratory model. A micro-drip infusion set, plugged into a bag of normal saline, was connected to a high-flow stopcock at the distal end. Vertically oriented IV catheters (gauges 14-22) were connected to the stopcock. The fluid meniscus height in the bag was fixed (60-120 cm) above the outflow point. The roller clamp on the infusion set was in fully open position for all experiments resulting in a continuous column of fluid in the drip chamber. Fluid volume delivered in 1 minute was measured 4 times with each condition. To model resistive effects of carrier flow, volumetric infusion pumps were used to deliver various flow rates of normal saline through a carrier IV set into which a micro-drip infusion was "piggybacked." We also compared delivery by micro-drip infusion sets from 3 manufacturers. The volume of fluid delivered by gravity-driven infusion under wide-open conditions (continuous fluid column in drip chamber) varied 2.9-fold (95% confidence interval, 2.84-2.96) depending on catheter size and fluid column height. Total model resistance of the micro-drip with stopcock and catheter varied with flow rate. Volume delivered by the piggybacked micro-drip decreased up to 29.7% ± 0.8% (mean ± SE) as the carrier flow increased from 0 to 1998 mL/min. Delivery characteristics of the micro-drip infusion sets from 3 different manufacturers were similar. Laboratory simulation of clinical situations with gravity

  5. Infusion of radionuclides throughout pregnancy

    International Nuclear Information System (INIS)

    Mountford-Lister, P.G.; Lambert, B.E.; Milner, A.C.; Kang, X.Z.

    1992-01-01

    This work is part of a long-term study to examine the cancer incidence in the offspring of mice exposed to 239 Pu or 147 Pm throughout pregnancy. The need to model the human intake scenario and the possibility of a critical period during uterine development necessitates constant availability of radionuclides throughout pregnancy. Various methods (multiple daily injections, infusion by external cannula and infusion by indwelling osmotic pump) have been examined and osmotic infusion pumps chosen. These pumps result in a near-constant blood concentration for up to 21 days. Part of the study is the estimation of dose to the critical haemopoietic tissues of the pup from a knowledge of the radionuclide distribution and kinetics. At present the distribution has been followed from birth to 180 days. Activity in the suckling pups at 7 days old is around 1 percent of the infused activity, though most of this is accounted for by the contents of the stomach and gastrointestinal tract. The liver and femur account for around 0.025 percent and 0.012 percent respectively per pup. Activity increases in both liver and femur during lactation after which both concentration and activity fall with time. Long-term studies with the pups of dams exposed to a range of 239 Pu concentrations between 0-70 kBq/kg are underway. Correlation of average organ dose with tumour incidence will be determined at completion of the life-span study. (Author) 39 refs., 5 tabs., 6 figs

  6. Numerical and clinical precision of continuous glucose monitoring in Colombian patients treated with insulin infusion pump with automated suspension in hypoglycemia.

    Science.gov (United States)

    Gómez, Ana M; Marín Sánchez, Alejandro; Muñoz, Oscar M; Colón Peña, Christian Alejandro

    2015-12-01

    Insulin pump therapy associated with continuous glucose monitoring has shown a positive clinical impact on diabetes control and reduction of hypoglycemia episodes. There are descriptions of the performance of this device in other populations, but its precision and accuracy in Colombia and Latin America are unknown, especially in the routine outpatient setting. Data from 33 type 1 and type 2 diabetes patients with sensor-augmented pump therapy with threshold suspend automation, MiniMed Paradigm® Veo™ (Medtronic, Northridge, California), managed at Hospital Universitario San Ignacio (Bogotá, Colombia) and receiving outpatient treatment, were analyzed. Simultaneous data from continuous glucose monitoring and capillary blood glucose were compared, and their precision and accuracy were calculating with different methods, including Clarke error grid. Analyses included 2,262 continuous glucose monitoring -reference paired glucose values. A mean absolute relative difference of 20.1% was found for all measurements, with a value higher than 23% for glucose levels ≤75mg/dL. Global compliance with the ISO criteria was 64.9%. It was higher for values >75mg/dl (68.3%, 1,308 of 1,916 readings), than for those ≤ 75mg/dl (49.4%, 171 of 346 readings). Clinical accuracy, as assessed by the Clarke error grid, showed that 91.77% of data were within the A and B zones (75.6% in hypoglycemia). A good numerical accuracy was found for continuous glucose monitoring in normo and hyperglycemia situations, with low precision in hypoglycemia. The clinical accuracy of the device was adequate, with no significant safety concerns for patients. Copyright © 2015 SEEN. Published by Elsevier España, S.L.U. All rights reserved.

  7. Using higher doses to compensate for tubing residuals in extended-infusion piperacillin-tazobactam.

    Science.gov (United States)

    Lam, Wendy J; Bhowmick, Tanaya; Gross, Alan; Vanschooneveld, Trevor C; Weinstein, Melvin P

    2013-06-01

    To mathematically assess drug losses due to infusion line residuals and evaluate methods to compensate for drug loss due to residual volumes in intravenous pump tubing. Literature was accessed through Ovid MEDLINE (1996-February 2013), using combinations of the search terms tubing residuals, residual volume, residual medication, intravenous infusions, intravenous injections, piperacillin, piperacillin-tazobactam, β-lactams, equipment design, infusion pumps, extended infusion, extended administration, and prolonged infusion. In addition, select reference citations from publications identified were reviewed. All articles that involved extended-infusion piperacillin-tazobactam implementation strategies were included in the review. Infusion pump characteristics and tubing residuals can affect extended-infusion piperacillin-tazobactam dosing strategies. Two studies addressing tubing residuals were identified. Both studies recommended increasing infusion volumes to compensate for tubing residuals. One study also recommended decreasing infusion-line dead space by using alternative infusion pump systems. Study calculations suggest that higher doses of piperacillin-tazobactam may be used to account for medication left in tubing residuals if alternative infusion pump systems cannot be obtained, and increased infusion volumes are not an option. Extended-infusion piperacillin-tazobactam has been used as a method of maximizing pharmacodynamic target attainment. Use of higher doses of piperacillin-tazobactam may be a reasonable method to compensate for drug loss due to residual volumes in large-bore intravenous pump tubing.

  8. Sodium pumping: pump problems

    International Nuclear Information System (INIS)

    Guer, M.; Guiton, P.

    Information on sodium pumps for LMFBR type reactors is presented concerning ring pump design, pool reactor pump design, secondary pumps, sodium bearings, swivel joints of the oscillating annulus, and thermal shock loads

  9. Krypton 81m infusion studies. Chapter 18

    International Nuclear Information System (INIS)

    Kaplan, E.; Mayron, L.W.; Friedman, A.M.; Gindler, J.E.

    1978-01-01

    A technique is described to give a continuous, constant-rate, intravascular infusion of 81 Krsup(m). Modifications of earlier generators included production of sodium-free 81 Rb, the use of a solution of commercial sterile isotonic non-ionic 5% dextrose-in-water as an eluant, the incorporation of a constant-rate infusion pump, and the miniaturization of the generator column and catheter system. Results are presented of studies of 81 Krsup(m) distribution in dogs, using both intravenous and intra-arterial infusion. (author)

  10. Increasing the volumetric efficiency of Diesel engines by intake pipes

    Science.gov (United States)

    List, Hans

    1933-01-01

    Development of a method for calculating the volumetric efficiency of piston engines with intake pipes. Application of this method to the scavenging pumps of two-stroke-cycle engines with crankcase scavenging and to four-stroke-cycle engines. The utility of the method is demonstrated by volumetric-efficiency tests of the two-stroke-cycle engines with crankcase scavenging. Its practical application to the calculation of intake pipes is illustrated by example.

  11. Dextrose boluses versus burette dextrose infusions in prevention of ...

    African Journals Online (AJOL)

    Background: Hypoglycemia is a major cause of morbidity and mortality among preterm infants and its management remains a challenge in resource limited settings. Use of dextrose infusion by the recommended infusion pumps is not feasible in our environment due to their high costs and yet the current use of mini dextrose ...

  12. Baxter elastomeric pumps: Feasibility of weight estimates.

    Science.gov (United States)

    Chambers, Carole R; Pabia, Mica; Sawyer, Michael; Tang, Patricia A

    2017-09-01

    Purpose Elastomeric pumps are used to infuse a 46-h fluorouracil protocol and patients are asked to visually inspect the pump daily. The pump has a variability of ±10% and there are additional patient variables that can increase this. The feasibility of weighing the pump rather than a visual inspection along with the secondary objective to confirm the pump's variability in real world conditions was undertaken. Methods Empty pumps were weighed using both pharmacy and kitchen scales. Pumps upon completion of the 46-h infusion were also weighed using both pharmacy and kitchen scales. Results The kitchen scale was as accurate as the pharmacy grade scale. Disconnected pumps showed the expected variability from using these infusor pumps along with a few showing greater variability likely due to patient variables. Conclusion Weighing pumps appears to be feasible both at the pharmacy and home level. Next steps would be to weigh pumps during the infusion to validate an alternate method to simple visual inspection for patients to confirm proper infusing of the pump at their home.

  13. Improved usability of a multi-infusion setup using a central control display

    NARCIS (Netherlands)

    Doesburg, Frank; Cnossen, Fokeltje; Dieperink, Willem; Bult, Wouter; Nijsten, Maarten W

    2016-01-01

    Infusion pumps are often associated with poor usability and an increased likelihood of medication errors [1]. Critically ill patients in the intensive care unit (ICU) usually receive multiple infusions simultaneously, which increases the likelihood of pump-related errors. Furthermore, the ICU is

  14. Hepatic artery infusion (HAI) for hepatic metastases in combination with hepatic resection and hepatic radiation

    International Nuclear Information System (INIS)

    Merrick, H.W.; Dobelbower, R.R.; Ringleint, J.F.; Skeel, R.T.

    1986-01-01

    Renewed interest in hepatic artery infusion has been stimulated by the development of a totally implantable pump which eliminates many of the problems encountered by the external pumps and catheters. As the potential benefit of hepatic artery infusion would be greater if either all gross disease were removed by prior resection, or alternatively, if non-resectable disease were irradiated in conjunction with hepatic artery infusion, the authors initiated a phase I-II trial to evaluate combined modality therapy

  15. Advancing medication infusion safety through the clinical integration of technology.

    Science.gov (United States)

    Gerhart, Donald; O'Shea, Kristen; Muller, Sharon

    2013-01-01

    Adverse drug events resulting from errors in prescribing or administering medications are preventable. Within a hospital system, numerous technologies are employed to address the common sources of medication error, including the use of electronic medical records, physician order entry, smart infusion pumps, and barcode medication administration systems. Infusion safety is inherently risky because of the high-risk medications administered and the lack of integration among the stand-alone systems in most institutions. Intravenous clinical integration (IVCI) is a technology that connects electronic medical records, physician order entry, smart infusion pumps, and barcode medication administration systems. It combines the safety features of an automatically programmed infusion pump (drug, concentration, infusion rate, and patient weight, all auto-programmed into the device) with software that provides visibility to real-time clinical infusion data. Our article describes the characteristics of IVCI at WellSpan Health and its impact on patient safety. The integrated infusion system has the capability of reducing medication errors, improving patient care, reducing in-facility costs, and supporting asset management. It can enhance continuous quality improvement efforts and efficiency of clinical work flow. After implementing IVCI, the institution realized a safer patient environment and a more streamlined work flow for pharmacy and nursing.

  16. Centrifugal pumps: fundamentals and classification

    International Nuclear Information System (INIS)

    Solar Manuel, A. M.

    2009-01-01

    Centrifugal pumps are usually employed to impulse water to elevate it, dose it or give it pressure or speed. They can be used with clean water or loaded with high solid concentration and don't work properly with air or another gas flow. There are another less used pumps, coming from volumetric or ram pumps to magnetic ones for specific uses. Centrifugal ones are rotokinetic pumps, like peripherical or lateral channel pumps. They work in a different way that non rotational kinetic ones and static ones. The work approaches their pre definition, selection, installation, operation and maintenance. It also review their morphology, hidromechanic principles and the basic elements pumps are made of. (Author)

  17. Volumetric composition of nanocomposites

    DEFF Research Database (Denmark)

    Madsen, Bo; Lilholt, Hans; Mannila, Juha

    2015-01-01

    is presented, using cellulose/epoxy and aluminosilicate/polylactate nanocomposites as case materials. The buoyancy method is used for the accurate measurements of materials density. The accuracy of the method is determined to be high, allowing the measured nanocomposite densities to be reported with 5...... significant figures. The plotting of the measured nanocomposite density as a function of the nanofibre weight content is shown to be a first good approach of assessing the porosity content of the materials. The known gravimetric composition of the nanocomposites is converted into a volumetric composition...

  18. Pulsatile versus steady infusions for hepatic artery chemotherapy

    International Nuclear Information System (INIS)

    Kim, E.E.; Haynie, T.P.; Wright, K.C.; Chaynsangavej, C.; Gianturco, C.; Lamki, L.; Wallace, S.

    1984-01-01

    Hepatic artery chemotherapy for unresectable liver tumors requires an even distribution of the drugs in the tumor or vascular bed. This cannot be determined angiographically because the drugs are infused at a much lower rate than the contrast media. It is easy, however, to determine the quality of the perfusion by injecting a small volume of Tc-99m MAA in one of the side ports while chemotherapeutic agent is being infused at the same rate. Usually this shows a uniform, satisfactory distribution of isotope. Occasionally, however, some areas fail to receive Tc-99m in spite of what appears to be a good position of the catheter tip. Since ''streaming'' of the infused drugs has been blamed for their uneven distribution, the authors decided to compare the usual steady flow infusions with infusions made pulsatile by the addition of a pulsing device (Gianturco Pump) attached to the infusion tubing. Eighty-three patients were studied with steady as well as pulsatile infusions. In 16 of these patients the perfusion pattern was definitely changed by the pulsatile infusion. In one patient the pulsatile mode resulted in an unwanted gastric perfusion. In 5 patients the distribution was improved in one hepatic lobe and in 10 patients it was improved in both lobes. These results show that hepatic artery perfusions can occasionally be improved by pulsing the infusate. However, pulsing can produce the unwanted perfusion of extra-hepatic areas

  19. Coaxial volumetric velocimetry

    Science.gov (United States)

    Schneiders, Jan F. G.; Scarano, Fulvio; Jux, Constantin; Sciacchitano, Andrea

    2018-06-01

    This study describes the working principles of the coaxial volumetric velocimeter (CVV) for wind tunnel measurements. The measurement system is derived from the concept of tomographic PIV in combination with recent developments of Lagrangian particle tracking. The main characteristic of the CVV is its small tomographic aperture and the coaxial arrangement between the illumination and imaging directions. The system consists of a multi-camera arrangement subtending only few degrees solid angle and a long focal depth. Contrary to established PIV practice, laser illumination is provided along the same direction as that of the camera views, reducing the optical access requirements to a single viewing direction. The laser light is expanded to illuminate the full field of view of the cameras. Such illumination and imaging conditions along a deep measurement volume dictate the use of tracer particles with a large scattering area. In the present work, helium-filled soap bubbles are used. The fundamental principles of the CVV in terms of dynamic velocity and spatial range are discussed. Maximum particle image density is shown to limit tracer particle seeding concentration and instantaneous spatial resolution. Time-averaged flow fields can be obtained at high spatial resolution by ensemble averaging. The use of the CVV for time-averaged measurements is demonstrated in two wind tunnel experiments. After comparing the CVV measurements with the potential flow in front of a sphere, the near-surface flow around a complex wind tunnel model of a cyclist is measured. The measurements yield the volumetric time-averaged velocity and vorticity field. The measurements of the streamlines in proximity of the surface give an indication of the skin-friction lines pattern, which is of use in the interpretation of the surface flow topology.

  20. Penis Pump

    Science.gov (United States)

    ... your appointment might be less involved. Choosing a penis pump Some penis pumps are available without a ... it doesn't get caught in the ring. Penis pumps for penis enlargement Many advertisements in magazines ...

  1. Continuous-infusion adriamycin

    International Nuclear Information System (INIS)

    Benjamin, R.S.; Chawla, S.P.; Ewer, M.S.; Hortobagyi, G.N.

    1986-01-01

    This chapter discusses the diminished cardiotoxicity as well as diminished nausea and vomiting with continuous infusions of adriamycin to patients undergoing radiation therapy, particularly with infusions of 48 hours or longer, and best with 96-hour infusions, the longest duration that has been studied systematically. In breast cancer, data show that more adriamycin is better, but only for a selected subgroup of patients: those with complete remission. The diminished cardiotoxicity makes the use of adriamycin more attractive in the adjuvant situation, where increased safety will decrease the chances of long-term complications and make retreatment easy for cured patients who develop second malignancies

  2. Malone-brayton cycle engine/heat pump

    Science.gov (United States)

    Gilmour, Thomas A.

    1994-07-01

    A machine, such as a heat pump, and having an all liquid heat exchange fluid, operates over a more nearly ideal thermodynamic cycle by adjustment of the proportionality of the volumetric capacities of a compressor and an expander to approximate the proportionality of the densities of the liquid heat exchange fluid at the chosen working pressures. Preferred forms of a unit including both the compressor and the expander on a common shaft employs difference in axial lengths of rotary pumps of the gear or vane type to achieve the adjustment of volumetric capacity. Adjustment of the heat pump system for differing heat sink conditions preferably employs variable compression ratio pumps.

  3. Absorption of subcutaneously infused insulin: influence of the basal rate pulse interval.

    Science.gov (United States)

    Hildebrandt, P; Birch, K; Jensen, B M; Kühl, C; Brange, J

    1985-01-01

    Eight insulin-dependent diabetic patients were given two constant infusions (each 1 IU/h) of 125I-labeled insulin into the abdominal subcutaneous tissue for about 12 h. Insulin was infused in pulses into one side of the abdomen in 6-min intervals (by means of an Auto-Syringe pump) and in the other side of the abdomen, insulin was infused in 1-h intervals (by means of a Medix pump). The size of the subcutaneous depots was continuously measured by counting the radioactivity at the infusion sites. After starting the infusions, the two depots were built up to steady-state levels at the same time and of the same size (approximately 3 IU) and with similar absorption rates. Thus, during basal rate insulin infusion, identical insulin absorption kinetics was achieved, irrespective of a 10-fold difference in the pulse rate.

  4. Centrifugal pumps

    CERN Document Server

    Anderson, HH

    1981-01-01

    Centrifugal Pumps describes the whole range of the centrifugal pump (mixed flow and axial flow pumps are dealt with more briefly), with emphasis on the development of the boiler feed pump. Organized into 46 chapters, this book discusses the general hydrodynamic principles, performance, dimensions, type number, flow, and efficiency of centrifugal pumps. This text also explains the pumps performance; entry conditions and cavitation; speed and dimensions for a given duty; and losses. Some chapters further describe centrifugal pump mechanical design, installation, monitoring, and maintenance. The

  5. Delivery interaction between co-infused medications: an in vitro modeling study of microinfusion.

    Science.gov (United States)

    Tsao, Amy C; Lovich, Mark A; Parker, Michael J; Zheng, Hui; Peterfreund, Robert A

    2013-01-01

    To test the hypothesis that steady-state drug delivery by continuous infusion is predictably affected by a second drug infusion in the same lumen. Clinicians commonly administer two drugs by continuous infusion through one central venous catheter lumen (co-infusion). To limit fluid delivery, low flow rate carriers transport concentrated drug solutions; a method called microinfusion. How microinfusion delivery of one drug is affected by a second drug infusion has not been explored. Two water-soluble dyes, tartrazine and erioglaucine, infused at 3 ml · h(-1), modeled drug delivery through a four stopcock linear manifold and catheter lumen. A pump drove a carrier fluid (10 ml · h(-1)). After tartrazine reached steady-state delivery, erioglaucine entered downstream or upstream of the tartrazine infusion. Quantitative spectrophotometry measured dye delivery. Starting erioglaucine's infusion upstream of tartrazine's entry caused a transient tartrazine bolus (duration 10 min, peak drug delivery 20% higher than target levels). Starting erioglaucine's infusion downstream produced a similar amplitude, briefer, bolus. Stopping the erioglaucine infusion caused a transient reduction in tartrazine delivery. Measured delivery profiles were comparable to prediction models. We confirmed the hypothesis that delivery of one infused drug is transiently affected by starting or stopping a second drug infusion in the same line. The magnitude of the changes can be estimated quantitatively. The clinical impact depends on the drugs being co-infused and patient sensitivity, but could be clinically important; the findings have safety implications for infused medication delivery to critically ill or anesthetized children. We recommend minimizing infusion system dead volumes, connecting the most essential infusion(s) to the main fluid pathway as close as possible to the patient, and recognizing the potential for unintended alterations in delivery when multiple drugs co-infuse. © 2012

  6. Precision flow-controlled rubidium-82 generator for bolus and constant infusion studies

    International Nuclear Information System (INIS)

    Yano, Y.

    1981-01-01

    A unique flow rate controller and large reservoir pumping system have been developed for infusing rubidium-82 intravenously at bolus, constant, or variable infusion rates. Using rubidium-82 and the positron ring detector tomograph, extraction or flow information can be obtained in studies of the heart, head, or kidneys

  7. Continuous intraperitoneal insulin infusion in patients with 'brittle' diabetes

    DEFF Research Database (Denmark)

    DeVries, J H; Eskes, S A; Snoek, Frank J

    2002-01-01

    AIMS: To evaluate the effects of continuous intraperitoneal insulin infusion (CIPII) using implantable pumps on glycaemic control and duration of hospital stay in poorly controlled 'brittle' Dutch diabetes patients, and to assess their current quality of life. METHODS: Thirty-three patients were...

  8. Balanced pressure gerotor fuel pump

    Energy Technology Data Exchange (ETDEWEB)

    Raney, Michael Raymond; Maier, Eugen

    2004-08-03

    A gerotor pump for pressurizing gasoline fuel is capable of developing pressures up to 2.0 MPa with good mechanical and volumetric efficiency and satisfying the durability requirements for an automotive fuel pump. The pump has been designed with optimized clearances and by including features that promote the formation of lubricating films of pressurized fuel. Features of the improved pump include the use of a shadow port in the side plate opposite the outlet port to promote balancing of high fuel pressures on the opposite sides of the rotors. Inner and outer rotors have predetermined side clearances with the clearances of the outer rotor being greater than those of the inner rotor in order to promote fuel pressure balance on the sides of the outer rotor. Support of the inner rotor and a drive shaft on a single bushing with bearing sleeves maintains concentricity. Additional features are disclosed.

  9. Infusion MR arteriography during hepatic arterial infusion chemotherapy. Evaluation of clinical usefulness

    International Nuclear Information System (INIS)

    Uchino, Minako; Takizawa, Kenji

    2003-01-01

    We developed a new method of infusion MR arteriography (IMRA) via an implantable port system using an infusion pump for the evaluation of drug distribution during hepatic arterial infusion chemotherapy. The purposes of this study were to optimize the method and evaluate its clinical usefulness. We used 3D-T1 turbo field echo (TFE) as the most suitable sequence for IMRA according to the results of a phantom model experiment. We examined 33 cases of liver cancer that had been treated by arterial infusion chemotherapy via the port system. The following investigations were performed: degree of tumor enhancement, intra- and extra- hepatic perfusion abnormality, and related toxicity. The evaluation of images was performed separately by two radiologists. IMRA provided good images of contrast enhancement, to reveal the perfusion patterns. The treatment response rate in the tumor group with well enhancement was higher than that of the group with poor enhancement (p<0.0001). Extrahepatic perfusion was well visualized and was correlated with toxicity (p<0.0001). IMRA is a useful method to evaluate drug perfusion for the optimization of arterial infusion chemotherapy. (author)

  10. Polar representation of centrifugal pump homologous curves

    International Nuclear Information System (INIS)

    Veloso, Marcelo Antonio; Mattos, Joao Roberto Loureiro de

    2008-01-01

    Essential for any mathematical model designed to simulate flow transient events caused by pump operations is the pump performance data. The performance of a centrifugal pump is characterized by four basic parameters: the rotational speed, the volumetric flow rate, the dynamic head, and the hydraulic torque. Any one of these quantities can be expressed as a function of any two others. The curves showing the relationships between these four variables are called the pump characteristic curves, also referred to as four-quadrant curves. The characteristic curves are empirically developed by the pump manufacturer and uniquely describe head and torque as functions of volumetric flow rate and rotation speed. Because of comprising a large amount of points, the four-quadrant configuration is not suitable for computational purposes. However, it can be converted to a simpler form by the development of the homologous curves, in which dynamic head and hydraulic torque ratios are expressed as functions of volumetric flow and rotation speed ratios. The numerical use of the complete set of homologous curves requires specification of sixteen partial curves, being eight for the dynamic head and eight for the hydraulic torque. As a consequence, the handling of homologous curves is still somewhat complicated. In solving flow transient problems that require the pump characteristic data for all the operation zones, the polar form appears as the simplest way to represent the homologous curves. In the polar method, the complete characteristics of a pump can be described by only two closed curves, one for the dynamic head and other for the hydraulic torque, both in function of a single angular coordinate defined adequately in terms of the quotient between volumetric flow ratio and rotation speed ratio. The usefulness and advantages of this alternative method are demonstrated through a practical example in which the homologous curves for a pump of the type used in the main coolant loops of a

  11. Parametric representation of centrifugal pump homologous curves

    International Nuclear Information System (INIS)

    Veloso, Marcelo A.; Mattos, Joao R.L. de

    2015-01-01

    Essential for any mathematical model designed to simulate flow transient events caused by pump operations is the pump performance data. The performance of a centrifugal pump is characterized by four basic quantities: the rotational speed, the volumetric flow rate, the dynamic head, and the hydraulic torque. The curves showing the relationships between these four variables are called the pump characteristic curves. The characteristic curves are empirically developed by the pump manufacturer and uniquely describe head and torque as functions of volumetric flow rate and rotation speed. Because of comprising a large amount of points, this configuration is not suitable for computational purposes. However, it can be converted to a simpler form by the development of the homologous curves, in which dynamic head and hydraulic torque ratios are expressed as functions of volumetric flow and rotation speed ratios. The numerical use of the complete set of homologous curves requires specification of sixteen partial curves, being eight for the dynamic head and eight for the hydraulic torque. As a consequence, the handling of homologous curves is still somewhat complicated. In solving flow transient problems that require the pump characteristic data for all the operation zones, the parametric form appears as the simplest way to deal with the homologous curves. In this approach, the complete characteristics of a pump can be described by only two closed curves, one for the dynamic head and other for the hydraulic torque, both in function of a single angular coordinate defined adequately in terms of the quotient between volumetric flow ratio and rotation speed ratio. The usefulness and advantages of this alternative method are demonstrated through a practical example in which the homologous curves for a pump of the type used in the main coolant loops of a pressurized water reactor (PWR) are transformed to the parametric form. (author)

  12. Measured density and calculated baricity of custom-compounded drugs for chronic intrathecal infusion.

    Science.gov (United States)

    Hejtmanek, Michael R; Harvey, Tracy D; Bernards, Christopher M

    2011-01-01

    To minimize the frequency that intrathecal pumps require refilling, drugs are custom compounded at very high concentrations. Unfortunately, the baricity of these custom solutions is unknown, which is problematic, given baricity's importance in determining the spread of intrathecally administered drugs. Consequently, we measured the density and calculated the baricity of clinically relevant concentrations of multiple drugs used for intrathecal infusion. Morphine, clonidine, bupivacaine, and baclofen were weighed to within 0.0001 g and diluted in volumetric flasks to produce solutions of known concentrations (morphine 1, 10, 25, and 50 mg/mL; clonidine 0.05, 0.5, 1, and 3 mg/mL; bupivacaine 2.5, 5, 10, and 20 mg/mL; baclofen 1, 1.5, 2, and 4 mg/mL). The densities of the solutions were measured at 37°C using the mechanical oscillation method. A "best-fit" curve was calculated for plots of concentration versus density for each drug. All prepared solutions of clonidine and baclofen were hypobaric. Higher concentrations of morphine and bupivacaine were hyperbaric, whereas lower concentrations were hypobaric. The relationship between concentration and density is linear for morphine (r > 0.99) and bupivacaine (r > 0.99) and logarithmic for baclofen (r = 0.96) and clonidine (r = 0.98). This is the first study to examine the relationship between concentration and density for custom drug concentrations commonly used in implanted intrathecal pumps. We calculated an equation that defines the relationship between concentration and density for each drug. Using these equations, clinicians can calculate the density of any solution made from the drugs studied here.

  13. Heat pumps

    CERN Document Server

    Macmichael, DBA

    1988-01-01

    A fully revised and extended account of the design, manufacture and use of heat pumps in both industrial and domestic applications. Topics covered include a detailed description of the various heat pump cycles, the components of a heat pump system - drive, compressor, heat exchangers etc., and the more practical considerations to be taken into account in their selection.

  14. Heat pumps

    CERN Document Server

    Brodowicz, Kazimierz; Wyszynski, M L; Wyszynski

    2013-01-01

    Heat pumps and related technology are in widespread use in industrial processes and installations. This book presents a unified, comprehensive and systematic treatment of the design and operation of both compression and sorption heat pumps. Heat pump thermodynamics, the choice of working fluid and the characteristics of low temperature heat sources and their application to heat pumps are covered in detail.Economic aspects are discussed and the extensive use of the exergy concept in evaluating performance of heat pumps is a unique feature of the book. The thermodynamic and chemical properties o

  15. A New Approach in the Design of High-Risk Infusion Technology

    Directory of Open Access Journals (Sweden)

    Robert Murphy

    2010-01-01

    Full Text Available The syringe infusion pump has been established as the instrument of choice for high-risk infusions, where potent drugs are often delivered at low rates of flow. However, numerous instances of unexpected flow error with consequent patient physiological impact have been reported. These include unwanted bolus delivery on release of line occlusion, dosage fluctuation due to pump height change and fluid reflux within the multiple pump installations now common in the Intensive Care Unit (ICU. This article examines the performance of a typical ICU syringe infusion pump and identifies mechanical compliance, inherent in commercial designs, as a source of flow error that should not be ignored by equipment designers. A prototype low compliance system is described and tested with performance compared to the conventional design, demonstrating advantages in terms of lower flow error.

  16. Continuous intraperitoneal insulin infusion in the treatment of type 1 diabetes mellitus: Glycaemia and beyond

    OpenAIRE

    van Dijk, Peter R.

    2015-01-01

    Continuous intraperitoneal insulin infusion (CIPII) with an implantable pump is a last-resort treatment option for selected patients with type 1 diabetes mellitus (T1DM). As compared to the most commonly used forms of insulin administration -injections and an externally placed pump- which deliver insulin in the subcutaneous (SC) tissue, CIPII delivers the insulin in the intraperitoneal space. CIPII using an implantable pump is an unique treatment which has been available for more than 30 year...

  17. Superconducting bearings for a LHe transfer pump

    Science.gov (United States)

    Kloeppel, S.; Muehsig, C.; Funke, T.; Haberstroh, C.; Hesse, U.; Lindackers, D.; Zielke, S.; Sass, P.; Schoendube, R.

    2017-12-01

    Superconducting bearings are used in a number of applications for high speed, low loss suspension. Most of these applications suspend a warm shaft and thus require continuous cooling, which leads to additional power consumption. Therefore, it seems advantageous to use these bearings in systems that are inherently cold. One respective application is a submerged pump for the transfer of liquid helium into mobile dewars. Centrifugal pumps require tight sealing clearances, especially for low viscosity fluids and small sizes. This paper covers the design and qualification of superconducting YBCO bearings for a laboratory sized liquid helium transfer pump. Emphasis is given to the axial positioning, which strongly influences the achievable volumetric efficiency.

  18. Centrifugal pumps

    CERN Document Server

    Gülich, Johann Friedrich

    2014-01-01

    This book gives an unparalleled, up-to-date, in-depth treatment of all kinds of flow phenomena encountered in centrifugal pumps including the complex interactions of fluid flow with vibrations and wear of materials. The scope includes all aspects of hydraulic design, 3D-flow phenomena and partload operation, cavitation, numerical flow calculations, hydraulic forces, pressure pulsations, noise, pump vibrations (notably bearing housing vibration diagnostics and remedies), pipe vibrations, pump characteristics and pump operation, design of intake structures, the effects of highly viscous flows, pumping of gas-liquid mixtures, hydraulic transport of solids, fatigue damage to impellers or diffusers, material selection under the aspects of fatigue, corrosion, erosion-corrosion or hydro-abrasive wear, pump selection, and hydraulic quality criteria. As a novelty, the 3rd ed. brings a fully analytical design method for radial impellers, which eliminates the arbitrary choices inherent to former design procedures. The d...

  19. Pumping life

    DEFF Research Database (Denmark)

    Sitsel, Oleg; Dach, Ingrid; Hoffmann, Robert Daniel

    2012-01-01

    The name PUMPKIN may suggest a research centre focused on American Halloween traditions or the investigation of the growth of vegetables – however this would be misleading. Researchers at PUMPKIN, short for Centre for Membrane Pumps in Cells and Disease, are in fact interested in a large family o......’. Here we illustrate that the pumping of ions means nothing less than the pumping of life....

  20. The Effect of Milrinone on the Right Ventriclular Function in Patients with Reduced Right Ventricular Function Undergoing Off-pump Coronary Artery Bypass Graft Surgery

    Science.gov (United States)

    Lee, Jong Hwa; Oh, Young Jun; Shim, Yon Hee; Hong, Yong Woo; Yi, Gijong

    2006-01-01

    This investigation evaluated the effect of continuous milrinone infusion on right ventriclular (RV) function during off-pump coronary artery bypass graft (OPCAB) surgery in patients with reduced RV function. Fifty patients scheduled for OPCAB, with thermodilution RV ejection fraction (RVEF) milrinone (0.5 µg/kg/min) or control (saline) group. Hemodynamic variables and RV volumetric data measured by thermodilution method were collected as follows: after anesthesia induction (T1); 10 min after heart displacement for obtuse marginal artery anastomosis (T2); after pericardial closure (T3). Cardiac index and heart rate increased and systemic vascular resistance significantly decreased in milrinone group at T2. Initially lower RVEF of milrinone group was eventually comparable to control group after milrinone infusion. RVEF did not significantly change at T2 and T3 in both groups. RV end-diastolic volume in milrinone group consistently decreased from the baseline at T2 and T3. Continuous infusion of milrinone without a bolus demonstrated potentially beneficial effect on cardiac output and RV afterload in patients with reduced RV function during OPCAB. However, aggressive augmentation of intravascular volume seems to be necessary to maximize the effect of the milrinone in these patients. PMID:17043419

  1. [How to promote the respect of good infusion practices by meeting health care professionals?].

    Science.gov (United States)

    Le Reste, C; Fiedler, A; Dubois, S; Dewailly, A; Le Du, I; Cogulet, V

    2016-05-01

    Health care professionals often forget that there are risks associated with infusion therapy even if it is a common care. In order to assess this practice and to draw potential improvement actions, an audit of local gravity-flow intravenous infusion practices was conducted. The audit, based on a grid including 66 items from the medical prescription to the end of the infusion therapy administration, was conducted in the 6 units which use the most gravity-flow intravenous infusion devices. A multidisciplinary working group was created to decide and organize priority corrective measures in order to improve infusion practices and quality of healthcare. The audit enabled to observe 90hours of nurse's practices (96 infusions) and highlighted heterogeneity in infusion, in some cases inappropriate infusion practices and misuse of infusion devices. We found 4 main issues: labelling infusion therapy, training of health care professionals on good practices, support the purchase of infusion pumps and standardize perfusion line. An interactive educational program for nurses (workshops) was organized to enhance the respect of good practices: infusion identification at any time, respect of hygiene rules, flow rate regulation by counting drops, appropriate use of pumps and flow rate regulators. The audit drew up work priorities. The workshops made easier exchanges between professionals and had a warm welcome that's why it is essential to carry on such training. This collaborative approach between pharmacists, nurses, hygienists and biomedical technicians contribute to drug management improvement and promote optimal patient care. Copyright © 2015 Académie Nationale de Pharmacie. Published by Elsevier Masson SAS. All rights reserved.

  2. Chemical Stability of Telavancin in Elastomeric Pumps

    Directory of Open Access Journals (Sweden)

    Patrick Sand, MSc

    2015-12-01

    Conclusions: The results of this study indicate that telavancin remains chemically stable when diluted in the Intermate Infusion System and the Homepump Eclipse elastomeric pumps and stored at 2°C to 8°C for up to 8 days protected from light at the concentration range and dilution schemes evaluated.

  3. Thallium-201 infusion imaging

    International Nuclear Information System (INIS)

    Alazraki, N.; Kralios, A.; Wooten, W.W.

    1988-01-01

    To test the accuracy of Thallium-201 coronary artery infusion imaging of the earth during rapid changes in blood flow through a major coronary artery, the author performed a study in dogs correlating electromagnetic flow probe recordings with 201 Tl scintillation camera acquisitions. Hyperemic vascular response was produced experimentally in a major coronary artery by occlusion and release interventions which altered flow from baseline to zero during occlusion (20 seconds), followed by rapid flow increases approaching three times baseline immediately upon release of the occlusion. Flow returned to the baseline level within 60 seconds following release. Flow was also altered in a controlled fashion by other interventions. Recordings of Thallium uptake in the myocardium were displayed as a time histogram (counts per second squared vs time) which correlated very closely with electromagnetic flow probe recordings of flow (R=o.82-0.97). These experiments demonstrate a high degree of accuracy in Thallium infusion imaging to detect rapid changes in flow through a major coronary artery

  4. Effect of insulin pump infusion on comprehensive stress state of ...

    African Journals Online (AJOL)

    a control group (120 cases), administered continuous intravenous insulin, and a ... oxidative stress and stress hormone levels were compared between the ... metabolic acidosis and ketonuria, as a result of .... This resulting energy insufficiency.

  5. Liquid metals pumping

    International Nuclear Information System (INIS)

    Le Frere, J.P.

    1984-01-01

    Pumps used to pump liquid metals depend on the liquid metal and on the type of application concerned. One deals more particularly with electromagnetic pumps, the main pumps used with mechanical pumps. To pump sodium in the nuclear field, these two types of pumps are used; the pumps of different circuits of Super Phenix are presented and described [fr

  6. Infusion's greenfield subsidiary in Poland

    NARCIS (Netherlands)

    Williams, C.; van Eerde, W.; The, D.

    2012-01-01

    The president of Infusion Development Corporation was reviewing the progress of the new subsidiary the company had set up 15 months earlier in Krakow, Poland. The purpose of the subsidiary was to work with other Infusion offices around the world to provide innovative software development services to

  7. Electromagnetic pump

    International Nuclear Information System (INIS)

    Ito, Koji; Suetake, Norio; Aizawa, Toshie; Nakasaki, Masayoshi

    1998-01-01

    The present invention provides an electromagnetic pump suitable to a recycling pump for liquid sodium as coolants of an FBR type reactor. Namely, a stator module of the electromagnetic pump of the present invention comprises a plurality of outer laminate iron core units and outer stator modules stacked alternately in the axial direction. With such a constitution, even a long electromagnetic pump having a large number of outer stator coils can be manufactured without damaging electric insulation of the outer stator coils. In addition, the inner circumferential surface of the outer laminate iron cores is urged and brought into contact with the outer circumferential surface of the outer duct by an elastic material. With such a constitution, Joule loss heat generated in the outer stator coils and internal heat generated in the outer laminate iron cores can be released to an electroconductive fluid flowing the inner circumference of the outer duct by way of the outer duct. (I.S.)

  8. Electrokinetic pump

    Science.gov (United States)

    Patel, Kamlesh D.

    2007-11-20

    A method for altering the surface properties of a particle bed. In application, the method pertains particularly to an electrokinetic pump configuration where nanoparticles are bonded to the surface of the stationary phase to alter the surface properties of the stationary phase including the surface area and/or the zeta potential and thus improve the efficiency and operating range of these pumps. By functionalizing the nanoparticles to change the zeta potential the electrokinetic pump is rendered capable of operating with working fluids having pH values that can range from 2-10 generally and acidic working fluids in particular. For applications in which the pump is intended to handle highly acidic solutions latex nanoparticles that are quaternary amine functionalized can be used.

  9. Insulin Pump Malfunction During Hospitalization: Two Case Reports.

    Science.gov (United States)

    Faulds, Eileen R; Wyne, Kathleen L; Buschur, Elizabeth O; McDaniel, Jodi; Dungan, Kathleen

    2016-06-01

    Insulin pump malfunctions and failures continue to occur; however, more severe malfunctions such as the "runaway pump" phenomenon are rarely reported. This article describes two cases of pump malfunction in which pump users appear to have received an unsolicited bolus of insulin resulting in severe episodes of hypoglycemia during hospitalization. Both cases of insulin pump malfunction occurred in the inpatient setting at a large academic medical center in the United States. An analysis of the corresponding insulin pump downloads was performed. The Food and Drug Administration's (FDA's) Manufacturer and User Facility Device Experience (MAUDE) database was searched for similar cases involving Medtronic (Northridge, CA) insulin pumps using the terms "pump," "infusion," "insulin AND malfunction AND Medtronic." The two cases described show remarkable similarities, each demonstrating a severe hypoglycemic event preceded by an infusion site change followed by an alarm. In both cases a rapid spraying of insulin was reported. The insulin pump downloads validated much of the patients' and medical staff's descriptions of events. The FDA's MAUDE database search revealed 425 cases meeting our search term criteria. All cases were reviewed. Seven cases were identified involving independent movement of the reservoir piston. The cases detailed are the first to describe an insulin pump malfunction of this nature in the hospital setting involving unsolicited insulin boluses leading to severe hypoglycemia. The cases are particularly compelling in that they were witnessed by medical personnel. Providers and patients should receive instruction education on the recognition and management of insulin pump malfunction.

  10. Pumps and pump facilities. 2. ed.

    International Nuclear Information System (INIS)

    Bohl, W.; Bauerfeind, H.; Gutmann, G.; Leuschner, G.; Matthias, H.B.; Mengele, R.; Neumaier, R.; Vetter, G.; Wagner, W.

    1981-01-01

    This book deals with the common fundamental aspects of liquid pumps and gives an exemplary choice of the most important kinds of pumps. The scientific matter is dealt with by means of practical mathematical examples among other ways of presenting the matter. Survey of contents: Division on main operational data of pumps - pipe characteristics - pump characteristics - suction behaviour of the pumps - projecting and operation of rotary pumps - boiler feed pumps - reactor feed pumps - oscillating positive-displacement pumps - eccentric spiral pumps. (orig./GL) [de

  11. Fluidic pumps

    International Nuclear Information System (INIS)

    Priestman, G.H.

    1990-01-01

    A fluidic pump has primary and secondary vessels connected by a pipe, a displacement vessel having liquid to be delivered through a pipe via a rectifier provided with a feed tank. A drive unit delivers pressure fluid to a line to raise liquid and compress trapped gas or liquid in the space, including the pipe between the liquids in the two vessels and thus drive liquid out of the displacement vessel. The driving gas is therefore separated by the barrier liquid and the trapped gas or liquid from the liquid to be pumped which liquid could be e.g. radioactive. (author)

  12. Pumped storage

    International Nuclear Information System (INIS)

    Strauss, P.L.

    1991-01-01

    The privately financed 1,000 MW Rocky Point Pumped Storage Project located in central Colorado, USA, will be one of the world's highest head, 2,350 feet reversible pump/turbine projects. The project will offer an economical supply of peaking power and spinning reserve power to Colorado and other southwestern states. This paper describes how the project will be made compatible with the environmental conditions in the project area and the type of terrestrial mitigation measures that are being proposed for those situations where the project impacts the environment, either temporarily or permanently

  13. Volumetric and chemical control auxiliary circuit for a PWR primary circuit

    International Nuclear Information System (INIS)

    Costes, D.

    1990-01-01

    The volumetric and chemical control circuit has an expansion tank with at least one water-steam chamber connected to the primary circuit by a sampling pipe and a reinjection pipe. The sampling pipe feeds jet pumps controlled by valves. An action on these valves and pumps regulates the volume of the water in the primary circuit. A safety pipe controlled by a flap automatically injects water from the chamber into the primary circuit in case of ruptures. The auxiliary circuit has also systems for purifying the water and controlling the boric acid and hydrogen content [fr

  14. Rocuronium: automatic infusion versus manual administration with TOF monitorisation.

    Science.gov (United States)

    Ozturk Arikan, Fatma Gulcin; Turan, Guldem; Ozgultekin, Asu; Sivrikaya, Zubeyir; Cosar, Bekir Cem; Onder, Dondu Nisa

    2016-10-01

    TOF (train-of-four) monitoring provides objective data in application of neuromuscular blocking agent. Thus, applicator-based differences are eliminated and optimum muscle relaxation is maintained during operation. In the present study, we aimed to compare the effects of target-controlled infusion system and standard TOF monitoring, on use of rocuronium. ASA I-II patients, who were aged between 18 and 75 years and scheduled for elective abdominal surgery at Haydarpaşa Numune Training and Research Hospital, were enrolled in the study. In order to evaluate neuromuscular blockade, the patients in Group 1 were connected to the acceleromyography device of the target-controlled infusion pump (Veryark-CLMRIS-I-China) while the ones in Group 2 were connected to the routinely used acceleromyography device (TOF Watch SX). There was no significant difference between groups regarding patient characteristics, the durations of anaesthesia and surgery, quality of intubation, time to extubation and time to recovery (TOF ratio of 0.9). Intubation time was significantly longer in Group 1 (Automated group) as compared to Group 2 (Control group) (p rocuronium amount used in Group 1 was found to be significantly higher than the amount used in Group 2 (p rocuronium was administered via automatical infusion pump during anaesthesia.

  15. Increasing the use of 'smart' pump drug libraries by nurses: a continuous quality improvement project.

    Science.gov (United States)

    Harding, Andrew D

    2012-01-01

    The use of infusion pumps that incorporate "smart" technology (smart pumps) can reduce the risks associated with receiving IV therapies. Smart pump technology incorporates safeguards such as a list of high-alert medications, soft and hard dosage limits, and a drug library that can be tailored to specific patient care areas. Its use can help to improve patient safety and to avoid potentially catastrophic harm associated with medication errors. But when one independent community hospital in Massachusetts switched from older mechanical pumps to smart pumps, it neglected to assign an "owner" to oversee the implementation process. One result was that nurses were using the smart pump library for only 37% of all infusions.To increase pump library usage percentage-thereby reducing the risks associated with infusion and improving patient safety-the hospital undertook a continuous quality improvement project over a four-month period in 2009. With the involvement of direct care nurses, and using quantitative data available from the smart pump software, the nursing quality and pharmacy quality teams identified ways to improve pump and pump library use. A secondary goal was to calculate the hospital's return on investment for the purchase of the smart pumps. Several interventions were developed and, on the first of each month, implemented. By the end of the project, pump library usage had nearly doubled; and the hospital had completely recouped its initial investment.

  16. Design and performance evaluation of the "iTIVA" algorithm for manual infusion of intravenous anesthetics based on effect-site target

    NARCIS (Netherlands)

    D.E. Ramírez (David Eduardo); J.A. Calvache (Jose Andrés)

    2016-01-01

    textabstractIntroduction: Remifentanil and propofol infusion using TCI pumps has proven to be beneficial for the practice of anesthesia but the availability of these systems is limited. Objective: Designing a pharmacokinetic model-based algorithm for calculating manual infusion regimens to achieve

  17. Hologlyphics: volumetric image synthesis performance system

    Science.gov (United States)

    Funk, Walter

    2008-02-01

    This paper describes a novel volumetric image synthesis system and artistic technique, which generate moving volumetric images in real-time, integrated with music. The system, called the Hologlyphic Funkalizer, is performance based, wherein the images and sound are controlled by a live performer, for the purposes of entertaining a live audience and creating a performance art form unique to volumetric and autostereoscopic images. While currently configured for a specific parallax barrier display, the Hologlyphic Funkalizer's architecture is completely adaptable to various volumetric and autostereoscopic display technologies. Sound is distributed through a multi-channel audio system; currently a quadraphonic speaker setup is implemented. The system controls volumetric image synthesis, production of music and spatial sound via acoustic analysis and human gestural control, using a dedicated control panel, motion sensors, and multiple musical keyboards. Music can be produced by external acoustic instruments, pre-recorded sounds or custom audio synthesis integrated with the volumetric image synthesis. Aspects of the sound can control the evolution of images and visa versa. Sounds can be associated and interact with images, for example voice synthesis can be combined with an animated volumetric mouth, where nuances of generated speech modulate the mouth's expressiveness. Different images can be sent to up to 4 separate displays. The system applies many novel volumetric special effects, and extends several film and video special effects into the volumetric realm. Extensive and various content has been developed and shown to live audiences by a live performer. Real world applications will be explored, with feedback on the human factors.

  18. Volumetric velocimetry for fluid flows

    Science.gov (United States)

    Discetti, Stefano; Coletti, Filippo

    2018-04-01

    In recent years, several techniques have been introduced that are capable of extracting 3D three-component velocity fields in fluid flows. Fast-paced developments in both hardware and processing algorithms have generated a diverse set of methods, with a growing range of applications in flow diagnostics. This has been further enriched by the increasingly marked trend of hybridization, in which the differences between techniques are fading. In this review, we carry out a survey of the prominent methods, including optical techniques and approaches based on medical imaging. An overview of each is given with an example of an application from the literature, while focusing on their respective strengths and challenges. A framework for the evaluation of velocimetry performance in terms of dynamic spatial range is discussed, along with technological trends and emerging strategies to exploit 3D data. While critical challenges still exist, these observations highlight how volumetric techniques are transforming experimental fluid mechanics, and that the possibilities they offer have just begun to be explored.

  19. Volumetric Visualization of Human Skin

    Science.gov (United States)

    Kawai, Toshiyuki; Kurioka, Yoshihiro

    We propose a modeling and rendering technique of human skin, which can provide realistic color, gloss and translucency for various applications in computer graphics. Our method is based on volumetric representation of the structure inside of the skin. Our model consists of the stratum corneum and three layers of pigments. The stratum corneum has also layered structure in which the incident light is reflected, refracted and diffused. Each layer of pigment has carotene, melanin or hemoglobin. The density distributions of pigments which define the color of each layer can be supplied as one of the voxel values. Surface normals of upper-side voxels are fluctuated to produce bumps and lines on the skin. We apply ray tracing approach to this model to obtain the rendered image. Multiple scattering in the stratum corneum, reflective and absorptive spectrum of pigments are considered. We also consider Fresnel term to calculate the specular component for glossy surface of skin. Some examples of rendered images are shown, which can successfully visualize a human skin.

  20. Solar Pump

    Science.gov (United States)

    Pique, Charles

    1987-01-01

    Proposed pump moves liquid by action of bubbles formed by heat of sun. Tube of liquid having boiling point of 100 to 200 degrees F placed at focal axis of cylindrical reflector. Concentrated sunlight boils liquid at focus, and bubbles of vapor rise in tube, carrying liquid along with them. Pressure difference in hot tube sufficient to produce flow in large loop. Used with conventional flat solar heating panel in completely solar-powered heat-storage system.

  1. Improved Second-Generation 3-D Volumetric Display System. Revision 2

    Science.gov (United States)

    1998-10-01

    computer control, uses infrared lasers to address points within a rare-earth-infused solid glass cube. Already, simple animated computer-generated images...Volumetric Display System permits images to be displayed in a three- dimensional format that can be observed without the use of special glasses . Its...MM 120 nm 60 mm nI POLARIZING I $-"• -’’""BEAMSPLI’i-ER ) 4P40-MHz 50-MHz BW PLRZN i TeO2 MODULATORS TeO2 DEFLECTORS Figure 1-4. NEOS four-channel

  2. Diaphragm Pump With Resonant Piezoelectric Drive

    Science.gov (United States)

    Izenson, Michael G.; Kline-Schoder, Robert J.; Shimko, Martin A.

    2007-01-01

    A diaphragm pump driven by a piezoelectric actuator is undergoing development. This pump is intended to be a prototype of lightweight, highly reliable pumps for circulating cooling liquids in protective garments and high-power electronic circuits, and perhaps for some medical applications. The pump would be highly reliable because it would contain no sliding seals or bearings that could wear, the only parts subject to wear would be two check valves, and the diaphragm and other flexing parts could be designed, by use of proven methods, for extremely long life. Because the pump would be capable of a large volumetric flow rate and would have only a small dead volume, its operation would not be disrupted by ingestion of gas, and it could be started reliably under all conditions. The prior art includes a number piezoelectrically actuated diaphragm pumps. Because of the smallness of the motions of piezoelectric actuators (typical maximum strains only about 0.001), the volumetric flow rates of those pumps are much too small for typical cooling applications. In the pump now undergoing development, mechanical resonance would be utilized to amplify the motion generated by the piezoelectric actuator and thereby multiply the volumetric flow rate. The prime mover in this pump would be a stack of piezoelectric ceramic actuators, one end of which would be connected to a spring that would be part of a spring-and-mass resonator structure. The mass part of the resonator structure would include the pump diaphragm (see Figure 1). Contraction of the spring would draw the diaphragm to the left, causing the volume of the fluid chamber to increase and thereby causing fluid to flow into the chamber. Subsequent expansion of the spring would push the diaphragm to the right, causing the volume of the fluid chamber to decrease, and thereby expelling fluid from the chamber. The fluid would enter and leave the chamber through check valves. The piezoelectric stack would be driven electrically to

  3. The effect of barium infusion rate on the diagnostic value of small bowel enteroclysis

    International Nuclear Information System (INIS)

    Oudkerk, M.; Rijke, A.M.

    1988-01-01

    Although enteroclysis may have many advantages over the conventional methods of small bowel examination, the contrast material is not always infused at a rate appropriate to gain maximum diagnostic information. In this study, 190 patients were examined by small bowell enteroclysis at five contrast infusion rates ranging from 50 to 150 ml/min using a newly designed infusion pump system. The results show that at rates above 75 ml/min, motility disturbances are masked by small bowel dilatation and paralysis, transit times are extended and morphological detail is obscured. At rates below 75 ml/min, incomplete filling of the loops renders optimal diagnostic evaluation impossible. An infusion rate of 75 ml/min was found to be optimal for initiating small bowel studies. This rate can be adjusted for individual cases when pathology or drugs affect the motility of the small bowel. 13 refs.; 5 figs.; 1 table

  4. Hemodynamic effects of rapid and slow infusions of manganese chloride and gadolinium-DTPA in dogs

    International Nuclear Information System (INIS)

    Slutsky, R.A.; Peterson, T.; Strich, G.; Brown, J.J.

    1985-01-01

    The acute hemodynamic effects of two paramagnetic contrast materials, manganese chloride and gadolinium-DTPA, were examined in dogs using ultrasonic dimension gauge crystals. Slow infusions (more than 15 minutes) of MnCl 2 or Gd-DTPA via an infusion pump had no significant hemodynamic effects. When given in just over 1 minute, Gd-DTPA produced elevated left ventricular (LV) end diastolic pressure and minor dilation of the ventricle and slowed diastolic filling. MnCl 2 , given rapidly, reduced systemic vascular resistance, resulting in hypotension. With both agents, these side effects waned after 5-10 minutes. It is concluded that both Gd-DTPA and MnCl 2 can be given safely in 0.1-mm/kg doses when administered as a slow, continuous infusion. Slow, intravenous infusion of Gd-DTPA or MnCl 2 is likely to be tolerated well by even severely ill individuals

  5. Pumping behavior of sputter ion pumps

    International Nuclear Information System (INIS)

    Chou, T.S.; McCafferty, D.

    The ultrahigh vacuum requirements of ISABELLE is obtained by distributed pumping stations. Each pumping station consists of 1000 l/s titanium sublimation pump for active gases (N 2 , H 2 , O 2 , CO, etc.), and a 20 l/s sputter ion pump for inert gases (methane, noble gases like He, etc.). The combination of the alarming production rate of methane from titanium sublimation pumps (TSP) and the decreasing pumping speed of sputter ion pumps (SIP) in the ultrahigh vacuum region (UHV) leads us to investigate this problem. In this paper, we first describe the essential physics and chemistry of the SIP in a very clean condition, followed by a discussion of our measuring techniques. Finally measured methane, argon and helium pumping speeds are presented for three different ion pumps in the range of 10 -6 to 10 -11 Torr. The virtues of the best pump are also discussed

  6. intravenous infusion of chlorimipramine (anafranil)

    African Journals Online (AJOL)

    the already extensive outpatient facilities at Johannesburg. Hospital as well as the Tara Neuro-Psychiatric Hospital for long-term therapy. Technique of Chlorimipramine Infusion. Initially 1 ampoule of chlorimipramine 25 mg in 250 mg of 5°~ dextrose saline was administered intravenously at the rate of 60 drops per minute.

  7. A cross-sectional international survey of continuous subcutaneous insulin infusion in 377 children and adolescents with type 1 diabetes mellitus from 10 countries

    NARCIS (Netherlands)

    Danne, T; Battelino, T; Kordonouri, O; Hanas, R; Klinkert, C; Ludvigsson, J; Barrio, R; Aebi, C; Gschwend, S; Mullis, PE; Schumacher, U; Zumsteg, U; Morandi, A; Rabbone, [No Value; Cherubini, [No Value; Toni, S; de Beaufort, C; Hindmarsh, P; Sumner, A; van Waarde, WM; van den Berg, N; Phillip, M

    2005-01-01

    Objective: To document current practices using continuous subcutaneous insulin infusion (CSII) by downloading electronically the 90-d pump data held within the pump memory and relating that to clinical data from children and adolescents in different pediatric diabetes centers from Europe and Israel.

  8. Pump characteristics and applications

    CERN Document Server

    Volk, Michael

    2013-01-01

    Providing a wealth of information on pumps and pump systems, Pump Characteristics and Applications, Third Edition details how pump equipment is selected, sized, operated, maintained, and repaired. The book identifies the key components of pumps and pump accessories, introduces the basics of pump and system hydraulics as well as more advanced hydraulic topics, and details various pump types, as well as special materials on seals, motors, variable frequency drives, and other pump-related subjects. It uses example problems throughout the text, reinforcing the practical application of the formulae

  9. Comparison of rechargeable versus battery-operated insulin pumps: temperature fluctuations.

    Science.gov (United States)

    Vereshchetin, Paul; McCann, Thomas W; Ojha, Navdeep; Venugopalan, Ramakrishna; Levy, Brian L

    2016-01-01

    The role of continuous subcutaneous insulin infusion (insulin pumps) has become increasingly important in diabetes management, and many different types of these systems are currently available. This exploratory study focused on the reported heating issues that lithium-ion battery-powered pumps may have during charging compared with battery-operated pumps. It was found that pump temperature increased by 6.4°C during a long charging cycle of a lithiumion battery-operated pump under ambient temperatures. In an environmental-chamber kept at 35°C, the pump temperature increased by 4.4°C, which indicates that the pump temperature was above that of the recommended safety limit for insulin storage of 37°C. When designing new pumps, and when using currently available rechargeable pumps in warmer climates, the implications of these temperature increases should be taken into consideration. Future studies should also further examine insulin quality after charging.

  10. Comparison of peristaltic and Venturi pumps in bimanual microincisional cataract surgery.

    Science.gov (United States)

    Karaguzel, Hande; Karalezli, Aylin; Aslan, Bekir Sitki

    2009-12-01

    Comparison of peristaltic and Venturi pumps in bimanual microincision phacoemulsification on the success of the cataract surgery by using sleeveless phaco tip. Bimanual microincision phacoemulsification was done in 49 eyes using a 1.4-mm temporal clear corneal incision. A peristaltic pump was used in 23 eyes, and a Venturi pump was used in 26 eyes for phacoemulsification. Intraoperative complications, anterior chamber stability, and mean duration of surgery were recorded. Duration of surgery was shorter in the Venturi pump group. Anterior chamber stability could not be established in 17 eyes in the peristaltic pump group; it was established in all eyes in the Venturi pump group. Corneal burns were observed in two eyes in the peristaltic pump group and no eyes in the Venturi pump group. Use of a Venturi pump system and a vented gas-forced infusion system can significantly shorten surgery time and reduce risk of thermal burns.

  11. Continuous infusion versus daily injections of growth hormone (GH) for 4 weeks in GH-deficient patients

    DEFF Research Database (Denmark)

    Laursen, Torben; Jørgensen, Jens Otto Lunde; Jakobsen, Grethe

    1995-01-01

    effects with constant and pulsatile GH delivery. This study was carried out to compare the metabolic effects of longer term continuous infusion vs. daily injections of GH. Thirteen GH-deficient patients were studied in a cross-over design. The patients were randomized to receive GH as a continuous sc...... infusion by means of a portable pump for 1 month and as daily sc injections (at 1900 h) for another month. An average daily GH dosage (+/- SEM) of 3.15 +/- 0.27 IU was administered during both periods. Steady state 24-h profiles of GH, IGF-I, IGF-binding proteins (IGFBPs), insulin, glucose, lipid.......35 (infusion); P infusion induced higher nighttime than daytime GH levels (P = 0.01), indicating a diurnal variation in the absorption or clearance of GH. Serum IGF-I levels (micrograms per L) were slightly higher (P infusion [312...

  12. MONITORING TETESAN INFUS BERBASIS MIKROKONTROLER ATMEGA16

    Directory of Open Access Journals (Sweden)

    Ardiyanto Iqbal Nugroho

    2015-09-01

    Penelitian ini menghasilkan suatu alat monitoring tetesan infus yang dapat memberikan informasi mengenai laju kecepatan tetesan dan kondisi cairan pada infus. Sistem yang secara realtime dimonitoring oleh perawat ini dapat mengurangi permasalahan yang timbul karena kelalaian petugas. Sehingga perawat tidak secara manual dalam mengatur kecepatan tetesan infus dan meningkatkan pelayanan kepada pasien.

  13. Internal pump

    International Nuclear Information System (INIS)

    Kushima, Jun; Hayashi, Youjiro; Ueda, Masayuki.

    1997-01-01

    The present invention relates to an internal pump. A water hole allowing communication between internal and external circumferences of a stretch tube is provided at the portion of the stretch tube corresponding to a position where an end face of a nozzle portion of a motor case and an end face of a diffuser are joined with each other so that hot filtered water inside a pressure container which has entered from where the end face of the nozzle portion of the motor case and the end face of the diffuser are joined with each other is combined with the purged water so that it can be sent back to the pressure container again. (author) figs

  14. Chronic intrastriatal dopamine infusions in rats with unilateral lesions of the substantia nigra

    International Nuclear Information System (INIS)

    Hargraves, R.; Freed, W.J.

    1987-01-01

    This study examined the effects of continuously supplied dopamine delivered directly into the dopamine-deficient striatum. Rats received unilateral lesions of the substantia nigra by stereotaxic administration of 6-hydroxydopamine and were tested for apomorphine-induced rotational behavior and general activity. Osmotic mini-pumps were filled with dopamine in various concentrations, implanted subcutaneously and connected to a cannula implanted directly into the striatum. The system delivered solution at a rate of .5 μl/hr for two weeks. Dopamine in a dosage of 0.5 μg/per hour reduced apomorphine-induced rotational behavior by a mean of 52 +/- 5.8% (mean +/- SEM n=20) with a maximal individual decrease of 99%. There was no change in general activity or increase in stereotype behavior. Infusions of vehicle solutions did not decrease rotational behavior. Spread of the infused dopamine and its metabolites was estimated by adding 3 H-dopamine to the pumps in tracer quantities. Radioactivity was highly concentrated at the infusion site and decreased rapidly within a few mm from the infusion site. Continuous infusion methods may eventually prove to be effective in the treatment of nigro-striatal degenerative disease. 12 references, 4 figures

  15. Breastfeeding FAQs: Pumping

    Science.gov (United States)

    ... of pump is best? You can buy or rent a breast pump from lactation consultants, hospitals, retail ... place to do it. Many companies offer their employees pumping and nursing areas. If yours doesn't, ...

  16. Volumetric composition in composites and historical data

    DEFF Research Database (Denmark)

    Lilholt, Hans; Madsen, Bo

    2013-01-01

    The obtainable volumetric composition in composites is of importance for the prediction of mechanical and physical properties, and in particular to assess the best possible (normally the highest) values for these properties. The volumetric model for the composition of (fibrous) composites gives...... guidance to the optimal combination of fibre content, matrix content and porosity content, in order to achieve the best obtainable properties. Several composite materials systems have been shown to be handleable with this model. An extensive series of experimental data for the system of cellulose fibres...... and polymer (resin) was produced in 1942 – 1944, and these data have been (re-)analysed by the volumetric composition model, and the property values for density, stiffness and strength have been evaluated. Good agreement has been obtained and some further observations have been extracted from the analysis....

  17. Process conditions and volumetric composition in composites

    DEFF Research Database (Denmark)

    Madsen, Bo

    2013-01-01

    The obtainable volumetric composition in composites is linked to the gravimetric composition, and it is influenced by the conditions of the manufacturing process. A model for the volumetric composition is presented, where the volume fractions of fibers, matrix and porosity are calculated...... as a function of the fiber weight fraction, and where parameters are included for the composite microstructure, and the fiber assembly compaction behavior. Based on experimental data of composites manufactured with different process conditions, together with model predictions, different types of process related...... effects are analyzed. The applied consolidation pressure is found to have a marked effect on the volumetric composition. A power-law relationship is found to well describe the found relations between the maximum obtainable fiber volume fraction and the consolidation pressure. The degree of fiber...

  18. LMFBR with booster pump in pumping loop

    International Nuclear Information System (INIS)

    Rubinstein, H.J.

    1975-01-01

    A loop coolant circulation system is described for a liquid metal fast breeder reactor (LMFBR) utilizing a low head, high specific speed booster pump in the hot leg of the coolant loop with the main pump located in the cold leg of the loop, thereby providing the advantages of operating the main pump in the hot leg with the reliability of cold leg pump operation

  19. Liquid metal pump

    Science.gov (United States)

    Pennell, William E.

    1982-01-01

    The liquid metal pump comprises floating seal rings and attachment of the pump diffuser to the pump bowl for isolating structural deflections from the pump shaft bearings. The seal rings also eliminate precision machining on large assemblies by eliminating the need for a close tolerance fit between the mounting surfaces of the pump and the seals. The liquid metal pump also comprises a shaft support structure that is isolated from the pump housing for better preservation of alignment of shaft bearings. The shaft support structure also allows for complete removal of pump internals for inspection and repair.

  20. Liquid metal pump

    International Nuclear Information System (INIS)

    Pennell, W.E.

    1982-01-01

    The liquid metal pump comprises floating seal rings and attachment of the pump diffuser to the pump bowl for isolating structural deflections from the pump shaft bearings. The seal rings also eliminate precision machining on large assemblies by eliminating the need for a close tolerance fit between the mounting surfaces of the pump and the seals. The liquid metal pump also comprises a shaft support structure that is isolated from the pump housing for better preservation of alignment of shaft bearings. The shaft support structure also allows for complete removal of pump internals for inspection and repair

  1. Heat pump technology

    CERN Document Server

    Von Cube, Hans Ludwig; Goodall, E G A

    2013-01-01

    Heat Pump Technology discusses the history, underlying concepts, usage, and advancements in the use of heat pumps. The book covers topics such as the applications and types of heat pumps; thermodynamic principles involved in heat pumps such as internal energy, enthalpy, and exergy; and natural heat sources and energy storage. Also discussed are topics such as the importance of the heat pump in the energy industry; heat pump designs and systems; the development of heat pumps over time; and examples of practical everyday uses of heat pumps. The text is recommended for those who would like to kno

  2. Aluminum bioavailability from tea infusion.

    Science.gov (United States)

    Yokel, Robert A; Florence, Rebecca L

    2008-12-01

    The objective was to estimate oral Al bioavailability from tea infusion in the rat, using the tracer (26)Al. (26)Al citrate was injected into tea leaves. An infusion was prepared from the dried leaves and given intra-gastrically to rats which received concurrent intravenous (27)Al infusion. Oral Al bioavailability (F) was calculated from the area under the (26)Al, compared to (27)Al, serum concentration x time curves. Bioavailability from tea averaged 0.37%; not significantly different from water (F=0.3%), or basic sodium aluminum phosphate (SALP) in cheese (F=0.1-0.3%), but greater than acidic SALP in a biscuit (F=0.1%). Time to maximum serum (26)Al concentration was 1.25, 1.5, 8 and 4.8h, respectively. These results of oral Al bioavailability x daily consumption by the human suggest tea can provide a significant amount of the Al that reaches systemic circulation. This can allow distribution to its target organs of toxicity, the central nervous, skeletal and hematopoietic systems. Further testing of the hypothesis that Al contributes to Alzheimer's disease may be more warranted with studies focusing on total average daily food intake, including tea and other foods containing appreciable Al, than drinking water.

  3. Baxter elastomeric pumps: Weighing as an alternative to visual inspection.

    Science.gov (United States)

    Cusano, Ellen L; Ali, Raafi; Sawyer, Michael B; Chambers, Carole R; Tang, Patricia A

    2018-04-01

    Purpose Elastomeric pumps are used to administer 46-hour infusions of 5-fluorouracil (5FU). Baxter suggests patients visually monitor their pumps to ensure that infusions are proceeding correctly. This can be confusing and lead to concerns about under- or over-dosing. Baxter has not considered weighing pumps as a validated method for monitoring. This study aims to validate weighing as a more accurate method for patients and healthcare professionals, and describe real life Baxter Infusor™ variability. Methods Patients who had been started on a 46-hour 5FU infusion returned to the clinic approximately 24 h after starting treatment. The pump was weighed on a StarFrit kitchen scale, and date, time, and weights recorded. Patients were asked if they had a preference for weighing or visually inspecting their pump. Results Pumps ( n = 103) were weighed between 17.25 and 27.5 h after connection. The average weight of a pump was 189 g. Of 103 pumps weighed, 99 weighed less than expected, corresponding to average flow rates of 5.69 mL/h over the elapsed time. The expected flow rate is 5 mL/h with 10% variability. Average flow rates within the 17.25- to 27.5-hour window were 4.561 mL/h, which is 8.78% slower than expected, but within the 10% known variability. Forty-seven percent of patients didn't have a preference for either method, but for those who did have a preference, more than twice as many preferred weighing. Conclusion With proper education, weighing Baxter Infusors at home with kitchen scales can be an accepted and objective alternative to the current recommendation of visual inspection.

  4. Dry vacuum pumps

    International Nuclear Information System (INIS)

    Sibuet, R

    2008-01-01

    For decades and for ultimate pressure below 1 mbar, oil-sealed Rotary Vane Pumps have been the most popular solution for a wide range of vacuum applications. In the late 80ies, Semiconductor Industry has initiated the development of the first dry roughing pumps. Today SC applications are only using dry pumps and dry pumping packages. Since that time, pumps manufacturers have developed dry vacuum pumps technologies in order to make them attractive for other applications. The trend to replace lubricated pumps by dry pumps is now spreading over many other market segments. For the Semiconductor Industry, it has been quite easy to understand the benefits of dry pumps, in terms of Cost of Ownership, process contamination and up-time. In this paper, Technology of Dry pumps, its application in R and D/industries, merits over conventional pumps and future growth scope will be discussed

  5. Effect of different infusion regimens on colonic motility and efficacy of colostomy irrigation.

    Science.gov (United States)

    Gattuso, J M; Kamm, M A; Myers, C; Saunders, B; Roy, A

    1996-10-01

    The colonic motility response and short-term clinical effectiveness of colonic irrigation was studied in five patients with an end-colostomy, each of whom was studied on up to six occasions, using volumes of 500 and 1500 ml water infused under gravity and over a period of 2.5 and 5 min with a pump. The median baseline colonic luminal pressure was 14 cmH2O and rose to 42 cmH2O with a 500-ml infusion, and to 74 cmH2O with a 1500-ml infusion. Irrigation induced high-pressure (over 200 cmH2O) propagated waves which caused the efflux of colonic contents. These were more numerous after a 1500- than a 500-ml infusion (median 4.5 versus 2.0 respectively). There was no difference between the two volumes infused in the incidence of colostomy break-through before subsequent irrigation. Colostomy irrigation with 500-1500 ml water appears to produce intracolonic pressure rises that are safe. These volumes can be infused rapidly under gravity alone.

  6. Exploring interaction with 3D volumetric displays

    Science.gov (United States)

    Grossman, Tovi; Wigdor, Daniel; Balakrishnan, Ravin

    2005-03-01

    Volumetric displays generate true volumetric 3D images by actually illuminating points in 3D space. As a result, viewing their contents is similar to viewing physical objects in the real world. These displays provide a 360 degree field of view, and do not require the user to wear hardware such as shutter glasses or head-trackers. These properties make them a promising alternative to traditional display systems for viewing imagery in 3D. Because these displays have only recently been made available commercially (e.g., www.actuality-systems.com), their current use tends to be limited to non-interactive output-only display devices. To take full advantage of the unique features of these displays, however, it would be desirable if the 3D data being displayed could be directly interacted with and manipulated. We investigate interaction techniques for volumetric display interfaces, through the development of an interactive 3D geometric model building application. While this application area itself presents many interesting challenges, our focus is on the interaction techniques that are likely generalizable to interactive applications for other domains. We explore a very direct style of interaction where the user interacts with the virtual data using direct finger manipulations on and around the enclosure surrounding the displayed 3D volumetric image.

  7. Volumetric, dashboard-mounted augmented display

    Science.gov (United States)

    Kessler, David; Grabowski, Christopher

    2017-11-01

    The optical design of a compact volumetric display for drivers is presented. The system displays a true volume image with realistic physical depth cues, such as focal accommodation, parallax and convergence. A large eyebox is achieved with a pupil expander. The windshield is used as the augmented reality combiner. A freeform windshield corrector is placed at the dashboard.

  8. Solar Pumping : The Basics

    OpenAIRE

    World Bank Group

    2018-01-01

    Solar photovoltaic water pumping (SWP) uses energy from solar photovoltaic (PV) panels to power an electric water pump. The entire process, from sunlight to stored energy, is elegant and simple. Over last seven years, the technology and price of solar pumping have evolved dramatically and hence the opportunities it presents. Solar pumping is most competitive in regions with high solar inso...

  9. Multiple pump housing

    Science.gov (United States)

    Donoho, II, Michael R.; Elliott; Christopher M.

    2010-03-23

    A fluid delivery system includes a first pump having a first drive assembly, a second pump having a second drive assembly, and a pump housing. At least a portion of each of the first and second pumps are located in the housing.

  10. Centrifugal pump handbook

    CERN Document Server

    Pumps, Sulzer

    2010-01-01

    This long-awaited new edition is the complete reference for engineers and designers working on pump design and development or using centrifugal pumps in the field. This authoritative guide has been developed with access to the technical expertise of the leading centrifugal pump developer, Sulzer Pumps. In addition to providing the most comprehensive centrifugal pump theory and design reference with detailed material on cavitation, erosion, selection of materials, rotor vibration behavior and forces acting on pumps, the handbook also covers key pumping applications topics and operational

  11. Infusion of the solid coal using pressure independent valves to regulate flow

    Energy Technology Data Exchange (ETDEWEB)

    Goretz, H G; Betting, K

    1979-01-01

    In order to improve infusion into the solid coal, attempts were made to effect this through several holes using a single pump; however, the regulation of the quantity of water directed into each hole by a ball-valve tap connected to the injection pump was shown to lack precision - gives the causes of this defect. Satisfactory regulation was obtained by means of pressure- independent flow valves which operate on the principle of hydrodynamic pressure balance; describes method of operation. Underground tests proved satisfactory even with large pressure variations. The problem of dirt penetration during down times was eliminated by installing a check valve. The system proves economical to run.

  12. Heat pumps in combined heat and power systems

    DEFF Research Database (Denmark)

    Ommen, Torben Schmidt; Markussen, Wiebke Brix; Elmegaard, Brian

    2014-01-01

    Heat pumps have previously been proposed as a way to integrate higher amounts of renewable energy in DH (district heating) networks by integrating, e.g., wind power. The paper identifies and compares five generic configurations of heat pumps in DH systems. The operational performance...... of the considered cases. When considering a case where the heat pump is located at a CHP (combined heat and power) plant, a configuration that increases the DH return temperature proposes the lowest operation cost, as low as 12 EUR MWh-1 for a 90 °C e 40 °C DH network. Considering the volumetric heating capacity......, a third configuration is superior in all cases. Finally, the three most promising heat pump configurations are integrated in a modified PQ-diagram of the CHP plant. Each show individual advantages, and for two, also disadvantages in order to achieve flexible operation....

  13. UK service level audit of insulin pump therapy in paediatrics.

    Science.gov (United States)

    Ghatak, A; Paul, P; Hawcutt, D B; White, H D; Furlong, N J; Saunders, S; Morrison, G; Langridge, P; Weston, P J

    2015-12-01

    To conduct an audit of insulin pump therapy in the UK after the issue of guidelines for the use of continuous subcutaneous insulin infusion by NICE in 2008 (Technology Appraisal 151). All centres in the UK, providing pump services to children and young people were invited to participate in an online audit. Audit metrics were aligned to NICE Technology Appraisal 151 and an electronic data collection tool was used. Of the 176 UK centres identified as providing pump services, 166 (94.3%) participated in the study. A total of 5094 children and young people were identified as using continuous subcutaneous insulin infusion (19% of all paediatric patients with Type 1 diabetes), with a median (range) of 16.9 (0.67-69.4)% per centre. Units had a median of 0.58 consultant sessions, 0.43 full-time equivalent diabetic specialist nurses, and 0.1 full-time equivalent dieticians delivering the pump service. The majority of this time was not formally funded. Families could access 24-h clinical and technical support (83% units), although the delivery varied between consultant, diabetic specialist nurse and company representatives. Only 53% of units ran, or accessed, structured education programmes for continuous subcutaneous insulin infusion use. Most units (86%) allowed continuous subcutaneous insulin infusion use for paediatric inpatients, but only 56% had written guidelines for this scenario. Nine percent of units had encountered funding refusal for a patient fulfilling NICE (Technology Appraisal 151) criteria. The number of children and young people on continuous subcutaneous insulin infusion therapy is consistent with numbers estimated by NICE. There is a worrying lack of funded healthcare professional time. The audit also identified gaps in the provision of structured education and absence of written inpatient guidelines. © 2015 The Authors. Diabetic Medicine © 2015 Diabetes UK.

  14. Infusing PDA technology into nursing education.

    Science.gov (United States)

    White, Ann; Allen, Patricia; Goodwin, Linda; Breckinridge, Daya; Dowell, Jeffery; Garvy, Ryan

    2005-01-01

    Use of the personal digital assistant (PDA) has been infused into the accelerated baccalaureate program at Duke University to help prepare nursing students for professional practice. The authors provide an overview of the use of PDAs in the classroom, laboratory, and clinical setting. Technical aspects of PDA infusion and steps to ensure regulatory compliance are explored. Benefits of PDA use by both faculty and students in the program and challenges met with the infusion of this technology are also described.

  15. A micro surface tension pump (MISPU) in a glass microchip.

    Science.gov (United States)

    Peng, Xing Yue Larry

    2011-01-07

    A non-membrane micro surface tension pump (MISPU) was fabricated on a glass microchip by one-step glass etching. It needs no material other than glass and is driven by digital gas pressure. The MISPU can be seen working like a piston pump inside the glass microchip under a microscope. The design of the valves (MISVA) and pistons (MISTON) was based on the surface tension theory of the micro surface tension alveolus (MISTA). The digital gas pressure controls the moving gas-liquid interface to open or close the input and output MISVAs to refill or drive the MISTON for pumping a liquid. Without any moving parts, a MISPU is a kind of long-lasting micro pump for micro chips that does not lose its water pumping efficiency over a 20-day period. The volumetric pump output varied from 0 to 10 nl s(-1) when the pump cycle time decreased from 5 min to 15 s. The pump head pressure was 1 kPa.

  16. Pumping mechanisms in sputter-ion pumps low pressure operation

    International Nuclear Information System (INIS)

    Welch, K.M.

    1991-01-01

    It is shown that significant H 2 pumping occurs in the walls of triode pumps. Also, H 2 is pumped in the anode cells of sputter-ion pumps. This pumping occurs in a manner similar to that by which the inert gases are pumped. That is, H 2 pumped in the walls of the anode cells by high energy neutral burial. Hydrogen in the pump walls and anodes limits the base pressure of the pump. 13 refs., 5 figs., 1 tab

  17. Pumping mechanisms in sputter-ion pumps low pressure operation

    International Nuclear Information System (INIS)

    Welch, K.M.

    1991-01-01

    It is shown that significant H 2 pumping occurs in the walls of triode pumps. Also, H 2 is pumped in the anode cells of sputter-ion pumps. This pumping occurs in a manner similar to that by which the inert gases are pumped. That is, H 2 is pumped in the walls of the anode cells by high energy neutral burial. Hydrogen in the pump walls and anodes limits the base pressure of the pump

  18. Adsorption pump for helium pumping out

    International Nuclear Information System (INIS)

    Donde, A.L.; Semenenko, Yu.E.

    1981-01-01

    Adsorption pump with adsorbent cooling by liquid helium is described. Shuttered shield protecting adsorbent against radiation is cooled with evaporating helium passing along the coil positioned on the shield. The pump is also equipped with primed cylindrical shield, cooled with liquid nitrogen. The nitrogen shield has in the lower part the shuttered shield, on the pump casing there is a valve used for pump pre-burning, and valves for connection to recipient as well. Pumping- out rates are presented at different pressures and temperatures of adsorbent. The pumping-out rate according to air at absorbent cooling with liquid nitrogen constituted 5x10 -4 Pa-3000 l/s, at 2x10 -2 Pa-630 l/s. During the absorbent cooling with liquid hydrogen the pumping-out rate according to air was at 4x10 -4 Pa-580 l/s, at 2x10 -3 Pa-680 l/s, according to hydrogen - at 8x10 -5 Pa-2500 l/s, at 5x10 -3 Pa-4200 l/s. During adsorbent cooling with liquid helium the rate of pumping-out according to hydrogen at 3x10 5 Pa-2400% l/s, at 6x10 3 Pa-1200 l/s, and according to helium at 3.5x10 -5 Pa-2800 l/s, at 4x10 -3 Pa-1150 l/s. The limit vacuum is equal to 1x10 -7 Pa. The volume of the vessel with liquid helium is equal to 3.5 l. Helium consumption is 80 cm 3 /h. Consumption of liquid nitrogen from the shield is 400 cm 3 /h. The limit pressure in the pump is obtained after forevacuum pumping-out (adsorbent regeneration) at 300 K temperature. The pump is made of copper. The pump height together with primed tubes is 800 mm diameter-380 mm [ru

  19. Identification of drug combinations administered by continuous subcutaneous infusion that require analysis for compatibility and stability

    OpenAIRE

    Dickman, Andrew; Bickerstaff, Matthew; Jackson, Richard; Schneider, Jennifer; Mason, Stephen; Ellershaw, John

    2017-01-01

    Background A continuous subcutaneous infusion (CSCI) delivered via syringe pump is a method of drug administration used to maintain symptom control when a patient is no longer able to tolerate oral medication. Several classes of drugs, such as opioids, antiemetics, anticholinergics, antipsychotics and benzodiazepines are routinely administered by CSCI alone or in combinations. Previous studies attempting to identify the most-common CSCI combinations are now several years old and no longer ref...

  20. Infusion volume control and calculation using metronome and drop counter based intravenous infusion therapy helper.

    Science.gov (United States)

    Park, Kyungnam; Lee, Jangyoung; Kim, Soo-Young; Kim, Jinwoo; Kim, Insoo; Choi, Seung Pill; Jeong, Sikyung; Hong, Sungyoup

    2013-06-01

    This study assessed the method of fluid infusion control using an IntraVenous Infusion Controller (IVIC). Four methods of infusion control (dial flow controller, IV set without correction, IV set with correction and IVIC correction) were used to measure the volume of each technique at two infusion rates. The infused fluid volume with a dial flow controller was significantly larger than other methods. The infused fluid volume was significantly smaller with an IV set without correction over time. Regarding the concordance correlation coefficient (CCC) of infused fluid volume in relation to a target volume, IVIC correction was shown to have the highest level of agreement. The flow rate measured in check mode showed a good agreement with the volume of collected fluid after passing through the IV system. Thus, an IVIC could assist in providing an accurate infusion control. © 2013 Wiley Publishing Asia Pty Ltd.

  1. Continuously pumping and reactivating gas pump

    International Nuclear Information System (INIS)

    Batzer, T.H.; Call, W.R.

    1984-01-01

    Apparatus for continuous pumping using cycling cyropumping panels. A plurality of liquid helium cooled panels are surrounded by movable nitrogen cooled panels the alternatively expose or shield the helium cooled panels from the space being pumped. Gases condense on exposed helium cooled panels until the nitrogen cooled panels are positioned to isolate the helium cooled panels. The helium cooled panels are incrementally warmed, causing captured gases to accumulate at the base of the panels, where an independent pump removes the gases. After the helium cooled panels are substantially cleaned of condensate, the nitrogen cooled panels are positioned to expose the helium cooled panels to the space being pumped

  2. Continuously pumping and reactivating gas pump

    Science.gov (United States)

    Batzer, Thomas H.; Call, Wayne R.

    1984-01-01

    Apparatus for continuous pumping using cycling cyropumping panels. A plurality of liquid helium cooled panels are surrounded by movable nitrogen cooled panels the alternatively expose or shield the helium cooled panels from the space being pumped. Gases condense on exposed helium cooled panels until the nitrogen cooled panels are positioned to isolate the helium cooled panels. The helium cooled panels are incrementally warmed, causing captured gases to accumulate at the base of the panels, where an independent pump removes the gases. After the helium cooled panels are substantially cleaned of condensate, the nitrogen cooled panels are positioned to expose the helium cooled panels to the space being pumped.

  3. Economic benefits of improved insulin stability in insulin pumps.

    Science.gov (United States)

    Weiss, Richard C; van Amerongen, Derek; Bazalo, Gary; Aagren, Mark; Bouchard, Jonathan R

    2011-05-01

    Insulin pump users discard unused medication and infusion sets according to labeling and manufacturer's instructions. The stability labeling for insulin aspart (rDNA origin] (Novolog) was increased from two days to six. The associated savings was modeled from the perspective of a hypothetical one-million member health plan and the total United States population. The discarded insulin volume and the number of infusion sets used under a two-day stability scenario versus six were modeled. A mix of insulin pumps of various reservoir capacities with a range of daily insulin dosages was used. Average daily insulin dose was 65 units ranging from 10 to 150 units. Costs of discarded insulin aspart [rDNA origin] were calculated using WAC (Average Wholesale Price minus 16.67%). The cost of pump supplies was computed for the two-day scenario assuming a complete infusion set change, including reservoirs, every two days. Under the six-day scenario complete infusion sets were discarded every six days while cannulas at the insertion site were changed midway between complete changes. AWP of least expensive supplies was used to compute their costs. For the hypothetical health plan (1,182 pump users) the annual reduction in discarded insulin volume between scenarios was 19.8 million units. The corresponding cost reduction for the plan due to drug and supply savings was $3.4 million. From the U.S. population perspective, savings of over $1 billion were estimated. Using insulin that is stable for six days in pump reservoirs can yield substantial savings to health plans and other payers, including patients.

  4. Plant fibre composites - porosity and volumetric interaction

    DEFF Research Database (Denmark)

    Madsen, Bo; Thygesen, Anders; Lilholt, Hans

    2007-01-01

    the combination of a high fibre volume fraction, a low porosity and a high composite density is optimal. Experimental data from the literature on volumetric composition and density of four types of plant fibre composites are used to validate the model. It is demonstrated that the model provides a concept......Plant fibre composites contain typically a relative large amount of porosity, which considerably influences properties and performance of the composites. The large porosity must be integrated in the conversion of weight fractions into volume fractions of the fibre and matrix parts. A model...... is presented to predict the porosity as a function of the fibre weight fractions, and to calculate the related fibre and matrix volume fractions, as well as the density of the composite. The model predicts two cases of composite volumetric interaction separated by a transition fibre weight fraction, at which...

  5. Combined surface and volumetric occlusion shading

    KAUST Repository

    Schott, Matthias O.; Martin, Tobias; Grosset, A. V Pascal; Brownlee, Carson; Hollt, Thomas; Brown, Benjamin P.; Smith, Sean T.; Hansen, Charles D.

    2012-01-01

    In this paper, a method for interactive direct volume rendering is proposed that computes ambient occlusion effects for visualizations that combine both volumetric and geometric primitives, specifically tube shaped geometric objects representing streamlines, magnetic field lines or DTI fiber tracts. The proposed algorithm extends the recently proposed Directional Occlusion Shading model to allow the rendering of those geometric shapes in combination with a context providing 3D volume, considering mutual occlusion between structures represented by a volume or geometry. © 2012 IEEE.

  6. Combined surface and volumetric occlusion shading

    KAUST Repository

    Schott, Matthias O.

    2012-02-01

    In this paper, a method for interactive direct volume rendering is proposed that computes ambient occlusion effects for visualizations that combine both volumetric and geometric primitives, specifically tube shaped geometric objects representing streamlines, magnetic field lines or DTI fiber tracts. The proposed algorithm extends the recently proposed Directional Occlusion Shading model to allow the rendering of those geometric shapes in combination with a context providing 3D volume, considering mutual occlusion between structures represented by a volume or geometry. © 2012 IEEE.

  7. Volumetric and superficial characterization of carbon activated

    International Nuclear Information System (INIS)

    Carrera G, L.M.; Garcia S, I.; Jimenez B, J.; Solache R, M.; Lopez M, B.; Bulbulian G, S.; Olguin G, M.T.

    2000-01-01

    The activated carbon is the resultant material of the calcination process of natural carbonated materials as coconut shells or olive little bones. It is an excellent adsorbent of diluted substances, so much in colloidal form, as in particles form. Those substances are attracted and retained by the carbon surface. In this work is make the volumetric and superficial characterization of activated carbon treated thermically (300 Centigrade) in function of the grain size average. (Author)

  8. Volumetric polymerization shrinkage of contemporary composite resins

    OpenAIRE

    Nagem Filho, Halim; Nagem, Haline Drumond; Francisconi, Paulo Afonso Silveira; Franco, Eduardo Batista; Mondelli, Rafael Francisco Lia; Coutinho, Kennedy Queiroz

    2007-01-01

    The polymerization shrinkage of composite resins may affect negatively the clinical outcome of the restoration. Extensive research has been carried out to develop new formulations of composite resins in order to provide good handling characteristics and some dimensional stability during polymerization. The purpose of this study was to analyze, in vitro, the magnitude of the volumetric polymerization shrinkage of 7 contemporary composite resins (Definite, Suprafill, SureFil, Filtek Z250, Fill ...

  9. A volumetric data system for environmental robotics

    International Nuclear Information System (INIS)

    Tourtellott, J.

    1994-01-01

    A three-dimensional, spatially organized or volumetric data system provides an effective means for integrating and presenting environmental sensor data to robotic systems and operators. Because of the unstructed nature of environmental restoration applications, new robotic control strategies are being developed that include environmental sensors and interactive data interpretation. The volumetric data system provides key features to facilitate these new control strategies including: integrated representation of surface, subsurface and above-surface data; differentiation of mapped and unmapped regions in space; sculpting of regions in space to best exploit data from line-of-sight sensors; integration of diverse sensor data (for example, dimensional, physical/geophysical, chemical, and radiological); incorporation of data provided at different spatial resolutions; efficient access for high-speed visualization and analysis; and geometric modeling tools to update a open-quotes world modelclose quotes of an environment. The applicability to underground storage tank remediation and buried waste site remediation are demonstrated in several examples. By integrating environmental sensor data into robotic control, the volumetric data system will lead to safer, faster, and more cost-effective environmental cleanup

  10. MR volumetric assessment of endolymphatic hydrops

    International Nuclear Information System (INIS)

    Guerkov, R.; Berman, A.; Jerin, C.; Krause, E.; Dietrich, O.; Flatz, W.; Ertl-Wagner, B.; Keeser, D.

    2015-01-01

    We aimed to volumetrically quantify endolymph and perilymph spaces of the inner ear in order to establish a methodological basis for further investigations into the pathophysiology and therapeutic monitoring of Meniere's disease. Sixteen patients (eight females, aged 38-71 years) with definite unilateral Meniere's disease were included in this study. Magnetic resonance (MR) cisternography with a T2-SPACE sequence was combined with a Real reconstruction inversion recovery (Real-IR) sequence for delineation of inner ear fluid spaces. Machine learning and automated local thresholding segmentation algorithms were applied for three-dimensional (3D) reconstruction and volumetric quantification of endolymphatic hydrops. Test-retest reliability was assessed by the intra-class coefficient; correlation of cochlear endolymph volume ratio with hearing function was assessed by the Pearson correlation coefficient. Endolymph volume ratios could be reliably measured in all patients, with a mean (range) value of 15 % (2-25) for the cochlea and 28 % (12-40) for the vestibulum. Test-retest reliability was excellent, with an intra-class coefficient of 0.99. Cochlear endolymphatic hydrops was significantly correlated with hearing loss (r = 0.747, p = 0.001). MR imaging after local contrast application and image processing, including machine learning and automated local thresholding, enable the volumetric quantification of endolymphatic hydrops. This allows for a quantitative assessment of the effect of therapeutic interventions on endolymphatic hydrops. (orig.)

  11. MR volumetric assessment of endolymphatic hydrops

    Energy Technology Data Exchange (ETDEWEB)

    Guerkov, R.; Berman, A.; Jerin, C.; Krause, E. [University of Munich, Department of Otorhinolaryngology Head and Neck Surgery, Grosshadern Medical Centre, Munich (Germany); University of Munich, German Centre for Vertigo and Balance Disorders, Grosshadern Medical Centre, Marchioninistr. 15, 81377, Munich (Germany); Dietrich, O.; Flatz, W.; Ertl-Wagner, B. [University of Munich, Institute of Clinical Radiology, Grosshadern Medical Centre, Munich (Germany); Keeser, D. [University of Munich, Institute of Clinical Radiology, Grosshadern Medical Centre, Munich (Germany); University of Munich, German Centre for Vertigo and Balance Disorders, Grosshadern Medical Centre, Marchioninistr. 15, 81377, Munich (Germany); University of Munich, Department of Psychiatry and Psychotherapy, Innenstadtkliniken Medical Centre, Munich (Germany)

    2014-10-16

    We aimed to volumetrically quantify endolymph and perilymph spaces of the inner ear in order to establish a methodological basis for further investigations into the pathophysiology and therapeutic monitoring of Meniere's disease. Sixteen patients (eight females, aged 38-71 years) with definite unilateral Meniere's disease were included in this study. Magnetic resonance (MR) cisternography with a T2-SPACE sequence was combined with a Real reconstruction inversion recovery (Real-IR) sequence for delineation of inner ear fluid spaces. Machine learning and automated local thresholding segmentation algorithms were applied for three-dimensional (3D) reconstruction and volumetric quantification of endolymphatic hydrops. Test-retest reliability was assessed by the intra-class coefficient; correlation of cochlear endolymph volume ratio with hearing function was assessed by the Pearson correlation coefficient. Endolymph volume ratios could be reliably measured in all patients, with a mean (range) value of 15 % (2-25) for the cochlea and 28 % (12-40) for the vestibulum. Test-retest reliability was excellent, with an intra-class coefficient of 0.99. Cochlear endolymphatic hydrops was significantly correlated with hearing loss (r = 0.747, p = 0.001). MR imaging after local contrast application and image processing, including machine learning and automated local thresholding, enable the volumetric quantification of endolymphatic hydrops. This allows for a quantitative assessment of the effect of therapeutic interventions on endolymphatic hydrops. (orig.)

  12. Infusing Systems Thinking into Career Counseling

    Science.gov (United States)

    Ryan, Charles W.; Tomlin, James H.

    2010-01-01

    This study examined the role of career counselors in infusing systems thinking into occupational advising. The authors conducted a qualitative review and analysis of selected literature on systems thinking and analyzed trends for adaptation to career counseling practice. This analysis suggests that career counselors need to infuse systems…

  13. The U.S. home infusion market.

    Science.gov (United States)

    Monk-Tutor, M R

    1998-10-01

    Medicare legislation stimulated the development of home care services but also resulted in fragmentation of service components. In the 1980s, prospective pricing and diagnosis-related groups, and resulting pressures to reduce inpatient length of stay, prompted additional growth of the industry. Even so, in 1995 home care represented only 3% of total national expenditures on health care. The annual growth rate of the home infusion industry dropped from 64% in 1982-86 to 24% in 1986-93. While revenue per patient for home infusion is expected to decrease under managed care, an increasing number of patients will support continued market growth. The home infusion market is highly competitive, with only a few large national providers and many small local providers. In 1996, 29% of acute care hospitals provided or were developing a home care program. Community pharmacists' options in the home infusion area include independent services, partnerships, joint ventures, contracts with hospitals, and franchises. The home infusion market is being integrated into alternative sites, such as ambulatory infusion centers (AICs), as providers attempt to diversify to maintain managed care contracts. AICs provide infusion therapy and nursing to noninstitutionalized, nonhome-bound patients. Untapped sources for future growth of the infusion market include long-term-care facilities. More consistent studies of the home care market are needed. Despite slowed growth in recent years, home care has a strong market in the United States.

  14. The History of Target-Controlled Infusion

    NARCIS (Netherlands)

    Struys, Michel M. R. F.; De Smet, Tom; Glen, John (Iain) B.; Vereecke, Hugo E. M.; Absalom, Anthony R.; Schnider, Thomas W.

    Target-controlled infusion (TCI) is a technique of infusing IV drugs to achieve a user-defined predicted (target) drug concentration in a specific body compartment or tissue of interest. In this review, we describe the pharmacokinetic principles of TCI, the development of TCI systems, and technical

  15. Evaluating the use of the Cleo 90 infusion set for patients on a palliative care unit.

    Science.gov (United States)

    Schneider, Michael; Hoffmann, Martin; Lorenzl, Stefan

    2009-08-01

    Although the use of subcutaneous infusion is common in palliative care, problems can occur. Normally, butterfly needles are used; however, there are occasional issues with patients being able to walk around or with restless patients who suffer from delirium. In these cases, needles often dislocate; therefore, a small observational study was undertaken to evaluate the use of the Cleo 90 infusion set. The use of this needle system has been well established in diabetic patients who require continuous subcutaneous infusion of insulin, but has never been tested in a wider range of patients with other medications. In this 6-month study, 45 patients were identified for subcutaneous infusion and a total of 112 needles were used for this study, since we initially changed each site after 2 days to control the local site for adverse reactions. We have not observed any complications with drug combinations delivered via the attached tube and the needle, and have used up to five different drugs mixed together in a single syringe. Needles could be used for a mean time of 5 +/- 2 days (range 2-12 days). Local site reactions have been observed only with sodium chloride infusions, which were not delivered via a pump system. Reddening and induration of the skin occurred, but they were reversible after removing the needle. As this was a small study in only one unit, without standardization the results can only be observational. However, it has shown, for the first time, that the Cleo 90 needle can be safe and comfortable.

  16. Pumps in mining

    Energy Technology Data Exchange (ETDEWEB)

    1979-01-01

    This article looks at the pump industry as a whole, its historical links with the mining industry, their parallel develop ment, and at the individual manufacturers and pumps, services and auxillary products they have to offer.

  17. Photovoltaic pump systems

    Science.gov (United States)

    Klockgether, J.; Kiessling, K. P.

    1983-09-01

    Solar pump systems for the irrigation of fields and for water supply in regions with much sunshine are discussed. For surface water and sources with a hoisting depth of 12 m, a system with immersion pumps is used. For deep sources with larger hoisting depths, an underwater motor pump was developed. Both types of pump system meet the requirements of simple installation and manipulation, safe operation, maintenance free, and high efficiency reducing the number of solar cells needed.

  18. A comparison of the hourly output between the Ambu® Smart-Infuser™ Pain Pump and the On-Q Pump® with Select-A-Flow™ Variable Rate Controller with standard and overfill volumes.

    Science.gov (United States)

    Iliev, Peter; Bhalla, Tarun; Tobias, Joseph D

    2016-04-01

    The Ambu Smart-Infuser Pain Pump and the On-Q Pump with Select-a-Flow Variable Rate Controller are elastomeric devices with a flow regulator that controls the rate of infusion of a local anesthetic agent through a peripheral catheter. As a safety evaluation, we evaluated the infusion characteristics of these two devices when filled with manufacturer recommended standard volumes and when overfilled with a volume 50% in excess of that which is recommended. Nineteen disposable devices from the two manufacturers were used in this study. Nine were filled with 0.9% normal saline according to the respective manufacturers' recommendations (four Ambu pumps were filled with 650 ml and five On-Q pumps were filled with 550 ml) and 10 devices were 150% overfilled (five Ambu pumps were filled with 975 ml and five On-Q pumps were filled with 825 ml). All of the devices were set to infuse at 10 ml · h(-1) at room temperature (21°C) for 12 h. The fluid delivered during each 2-h period was measured using a graduated column. The On-Q pump (in the settings of normal fill and 150% overfill) delivered a significantly higher output per hour than the set rate during the first 8 h, while the Ambu pump delivered a value close to the set rate of 10 ml · h(-1). No significant difference in the hourly delivered output was noted for either device when comparing the normal fill to the 150% overfill groups. This investigation demonstrates that no change in the hourly output occurs with overfilling of these home infusion devices. However, as noted previously, the hourly output from the On-Q device is significantly higher than the set rate during the initial 8 h of infusion which could have potential clinical implications. © 2016 John Wiley & Sons Ltd.

  19. Rotary magnetic heat pump

    Science.gov (United States)

    Kirol, L.D.

    1987-02-11

    A rotary magnetic heat pump constructed without flow seals or segmented rotor accomplishes recuperation and regeneration by using split flow paths. Heat exchange fluid pumped through heat exchangers and returned to the heat pump splits into two flow components: one flowing counter to the rotor rotation and one flowing with the rotation. 5 figs.

  20. Vertical pump assembly

    International Nuclear Information System (INIS)

    Dohnal, M.; Rosel, J.; Skarka, V.

    1988-01-01

    The mounting is described of the drive assembly of a vertical pump for nuclear power plants in areas with seismic risk. The assembly is attached to the building floor using flexible and damping elements. The design allows producing seismically resistant pumps without major design changes in the existing types of vertical pumps. (E.S.). 1 fig

  1. Improvement of performance of vibration pump for molten salt at high temperature

    International Nuclear Information System (INIS)

    Watanabe, Hideo; Hashimoto, Hiroyuki; Katagiri, Kazunari; Tang Bomin.

    1996-01-01

    An experimental study was conducted to improve the performance of a vibration pump using a vibrating pipe for conveying the molten salt at 784 K. A new system to measure the pump performance safely at such a high temperature was developed, which was characterized by simplicity in construction and ease of operation. All parts of the system, including a pump, valves and a volume tank to measure the volumetric flow rate, were placed in a cylindrical tank. The pump was driven by an air actuator. Experimental results indicated that the measuring system fulfilled the intended function: the pump worked effectively and its performance was safely evaluated at a high temperature. A few possible improvements related to the construction of the pump were suggested based on the results. (author)

  2. Generic Safety Requirements for Developing Safe Insulin Pump Software

    Science.gov (United States)

    Zhang, Yi; Jetley, Raoul; Jones, Paul L; Ray, Arnab

    2011-01-01

    Background The authors previously introduced a highly abstract generic insulin infusion pump (GIIP) model that identified common features and hazards shared by most insulin pumps on the market. The aim of this article is to extend our previous work on the GIIP model by articulating safety requirements that address the identified GIIP hazards. These safety requirements can be validated by manufacturers, and may ultimately serve as a safety reference for insulin pump software. Together, these two publications can serve as a basis for discussing insulin pump safety in the diabetes community. Methods In our previous work, we established a generic insulin pump architecture that abstracts functions common to many insulin pumps currently on the market and near-future pump designs. We then carried out a preliminary hazard analysis based on this architecture that included consultations with many domain experts. Further consultation with domain experts resulted in the safety requirements used in the modeling work presented in this article. Results Generic safety requirements for the GIIP model are presented, as appropriate, in parameterized format to accommodate clinical practices or specific insulin pump criteria important to safe device performance. Conclusions We believe that there is considerable value in having the diabetes, academic, and manufacturing communities consider and discuss these generic safety requirements. We hope that the communities will extend and revise them, make them more representative and comprehensive, experiment with them, and use them as a means for assessing the safety of insulin pump software designs. One potential use of these requirements is to integrate them into model-based engineering (MBE) software development methods. We believe, based on our experiences, that implementing safety requirements using MBE methods holds promise in reducing design/implementation flaws in insulin pump development and evolutionary processes, therefore improving

  3. Volumetric polymerization shrinkage of contemporary composite resins

    Directory of Open Access Journals (Sweden)

    Halim Nagem Filho

    2007-10-01

    Full Text Available The polymerization shrinkage of composite resins may affect negatively the clinical outcome of the restoration. Extensive research has been carried out to develop new formulations of composite resins in order to provide good handling characteristics and some dimensional stability during polymerization. The purpose of this study was to analyze, in vitro, the magnitude of the volumetric polymerization shrinkage of 7 contemporary composite resins (Definite, Suprafill, SureFil, Filtek Z250, Fill Magic, Alert, and Solitaire to determine whether there are differences among these materials. The tests were conducted with precision of 0.1 mg. The volumetric shrinkage was measured by hydrostatic weighing before and after polymerization and calculated by known mathematical equations. One-way ANOVA (a or = 0.05 was used to determine statistically significant differences in volumetric shrinkage among the tested composite resins. Suprafill (1.87±0.01 and Definite (1.89±0.01 shrank significantly less than the other composite resins. SureFil (2.01±0.06, Filtek Z250 (1.99±0.03, and Fill Magic (2.02±0.02 presented intermediate levels of polymerization shrinkage. Alert and Solitaire presented the highest degree of polymerization shrinkage. Knowing the polymerization shrinkage rates of the commercially available composite resins, the dentist would be able to choose between using composite resins with lower polymerization shrinkage rates or adopting technical or operational procedures to minimize the adverse effects deriving from resin contraction during light-activation.

  4. Treatment of advanced and recurrent squamous carcinoma of the uterine cervix with constant intraarterial infusion of cisplatin

    International Nuclear Information System (INIS)

    Rettenmaier, M.A.; Moran, M.F.; Ramsinghani, N.F.; Colman, M.; Syed, N.A.; Puthawala, A.; Jansen, F.W.; DiSaia, P.J.

    1988-01-01

    Twelve patients with primary or locally recurrent squamous carcinoma of the cervix were treated with constant internal iliac artery infusion of cisplatin (CDDP) via a totally implantable chemotherapy pump. Seven previously untreated patients received standard external and interstitial radiotherapy (RT) in conjunction with CDDP infusion. Five patients with isolated pelvic recurrences received CDDP therapy only. The chemotherapy pump was refilled weekly on an outpatient basis. All nine evaluable patients developed unilateral or bilateral lower extremity pain which responded to dosage reduction. No renal or marrow toxicity was seen. Both of the evaluable patients treated for recurrent tumor died 32 and 60 weeks after initiation of treatment. The seven patients treated primarily with RT + CDDP infusion include one who expired with persistent tumor and one with no evidence of disease (NED) after exenteration for a pelvic recurrence at 48 and 85 weeks respectively. The five remaining patients are NED at 12 to 60 weeks. Constant internal iliac artery infusion of CDDP via an implantable chemotherapy pump can be performed with acceptable toxicity. The preliminary results suggest that further study in previously untreated undergoing concurrent radiotherapy is warranted

  5. Detection of pump degradation

    International Nuclear Information System (INIS)

    Casada, D.A.

    1994-01-01

    There are a variety of stressors that can affect the operation of centrifugal pumps. These can generally be classified as: Mechanical; Hydraulic; Tribological; Chemical; and Other (including those associated with the pump driver). Although these general stressors are active in essentially all centrifugal pumps, the stressor level and the extent of wear and degradation can vary greatly. Parameters that affect the extent of stressor activity are manifold. In order to assure the long-term operational readiness of a pump, it is important to both understand the nature and magnitude of the specific degradation mechanisms and to monitor the performance of the pump

  6. Liquid metal pump

    International Nuclear Information System (INIS)

    Pennell, W.E.

    1981-01-01

    A liquid metal pump comprising a shaft support structure which is isolated from the pump housing for better preservation of alignment of shaft bearings. The shaft carries an impeller and the support structure carries an impeller cage which is slidably disposed in a diffuser so as to allow complete removal of pump internals for inspection and repair. The diffuser is concentrically supported in the pump housing which also takes up all reaction forces generated by the discharge of the liquid metal from the diffuser, with floating seals arranged between impeller cage and the diffuser. The space between the diffuser and the pump housing permits the incoming liquid to essentially surround the diffuser. (author)

  7. Jet pump assisted artery

    Science.gov (United States)

    1975-01-01

    A procedure for priming an arterial heat pump is reported; the procedure also has a means for maintaining the pump in a primed state. This concept utilizes a capillary driven jet pump to create the necessary suction to fill the artery. Basically, the jet pump consists of a venturi or nozzle-diffuser type constriction in the vapor passage. The throat of this venturi is connected to the artery. Thus vapor, gas, liquid, or a combination of the above is pumped continuously out of the artery. As a result, the artery is always filled with liquid and an adequate supply of working fluid is provided to the evaporator of the heat pipe.

  8. Pharmacokinetics and toxicology of continuously infused nitroimidazoles

    International Nuclear Information System (INIS)

    Eifel, P.J.; Brown, J.M.

    1984-01-01

    The pharmacokinetics and toxicology of misonidazole (MISO) and SR-2508 given by continuous intraperitoneal infusion were studied in female C 3 H mice. The survival (time to death) of animals receiving continuous infusions of SR-2508 and MISO was compared and related to plasma concentration, rate of infusion and total amount of drug delivered. Brain and plasma concentrations were determined by HPLC. For SR-2508, plasma concentration was directly proportional to the infusion rate. However, as the infusion rate of MISO was doubled, the plasma concentration of MISO increased approximately 6-fold, reflecting a substantial increase in the apparent half-life. The brain/plasma concentration ratio in animals infused for up to 6 days with SR-2508 remained constant, at approximately 0.09. At plasma concentrations of 0.08-1.5 mM, animals receiving SR-2508 survived approximately 3 times as long as animals exposed to a comparable plasma concentration of MISO. Even at the lowest infusion rates employed in this study, the survival of mice receiving SR-2508 was much shorter than would have been predicted if the toxicity of these two drugs were solely related to the integral brain exposure. The low brain/plasma concentration ratio of SR-2508 was maintained throughout long continuous exposures

  9. The effect of glucagon on infusion cholangiography

    International Nuclear Information System (INIS)

    Evans, A.F.; Whitehouse, G.H.

    1979-01-01

    An assessment has been made of the effects of glucagon on biliary tract opacification during intravenous cholangiography. Two series of infusion cholangiograms were obtained at two investigating centres designated A and B. In series A, 41 patients had ioglycamide infusions at a rate of 0.2833 g min -1 over 1 h. In series B, 31 patients had ioglycamide infusions at a rate of 0.3886 g min -1 over 30 min. Radiographs were taken in both series immediately at the end of the infusion, 10 min later and 30 min after the infusion. Two mg of intravenous glucagon was injected into alternate cases in both series A and B immediately after the first radiograph was taken at the completion of the ioglycamide infusion. Two observers in each series then assessed the radiographic opacification of the biliary system without prior knowledge of which patients had received the glucagon. Delineation of the biliary system was considered better in both series in those patients who received glucagon when compared with the controls. Gallbladder opacification was definitely increased in series A in those receiving glucagon, and a similar tendency was shown in series B. The amount of contrast in the upper intestine was increased in series A in the glucagon group, but not in series B. It is concluded that glucagon improves visualisation of the biliary tract, especially the gallbladder at infusion cholangiography. (author)

  10. Pumps for nuclear facilities

    International Nuclear Information System (INIS)

    1999-01-01

    The guide describes how the Finnish Radiation and Nuclear Safety Authority (STUK) controls pumps and their motors at nuclear power plants and other nuclear facilities. The scope of the control is determined by the Safety Class of the pump in question. The various phases of the control are: (1) review of construction plan, (2) control of manufacturing, and construction inspection, (3) commissioning inspection, and (4) control during operation. STUK controls Safety Class 1, 2 and 3 pumps at nuclear facilities as described in this guide. STUK inspects Class EYT (non-nuclear) pumps separately or in connection with the commissioning inspections of the systems. This guide gives the control procedure and related requirements primarily for centrifugal pumps. However, it is also applied to the control of piston pumps and other pump types not mentioned in this guide

  11. Internal pump monitoring device

    International Nuclear Information System (INIS)

    Kurosaki, Toshikazu.

    1996-01-01

    In the present invention, a thermometer is disposed at the upper end of an internal pump casing of a coolant recycling system in a BWR type reactor to detect leakage of reactor water thereby ensuring the improvement of reliability of the internal pump. Namely, a thermometer is disposed, which can detect temperature elevation occurred when water in the internal pump leaked from a reactor pressure vessel passes through the gap between a stretch tube and an upper end of the pump casing. Signals from the thermometer are transmitted to a signal processing device by an instrumentation cable. The signal processing device generates an alarm when the temperature signal exceeds a predetermined value and announces that leakage of reactor water occurs in the internal pump. Since the present invention can detect the leakage of the reactor water in the pump casing in an early stage, it can contribute to the improvement of the safety and reliability of the internal pump. (I.S.)

  12. Thrombolytic treatment for acute ischemic cerebral stroke: intraarterial urokinase infusion vs. intravenous heparin and urokinase infusion

    International Nuclear Information System (INIS)

    Ko, Gi Young; Suh, Dae Chul; Lee, Jae Hong; Kim, Jun Hyoung; Choi, Choong Gon; Lee, Ho Kyu; Lee, Myoung Chong

    1996-01-01

    To evaluate the efficacy and limitation of intra-arterial urokinase (IAUK) infusion for treatment of acute cerebral stroke. Twenty-seven acute cerebral stroke patients treated with IAUK infusion within six hours of stroke onset were reviewed. All patients showed normal initial brain findings on CT. In 21 patients, urokinase(5-15 x 10 5 IU) was administered through a microcatheter placed into or proximal to occluded segment. Mechanical disruption of thrombus by guidewire was performed in 17 patients. Angiographic and clinical responses and complications after IAUK infusion, were evaluated and the results were compared with those of intravenous heparin(N=19) and urokinase infusion(N=19). Complete or partial angiographic recanalization of occluded segment was found in 18 patients (67%), and neurologic improvement was followed in 14 patients(52%). The degree of improvement on the stroke scale score after IAUK infusion was statistically more significant(p<0.05) than that shown after intravenous heparin and urokinase infusion. Complications after IAUK infusion were large(15%) and small amount intracerebral hemorrhage(15%), contrast leakage into brain parenchyma(11%), and gastrointestinal bleeding(4%). Between the IAVK and the intravenous urokinase infusion group, differences in extent and types of complications were statistically insignificant, but were significantly higher in those two groups than in the intravenous heparin infusion group. IAUK infusion may be effective for the treatment of acute cerebral stroke

  13. Financial analysis for the infusion alliance.

    Science.gov (United States)

    Perucca, Roxanne

    2010-01-01

    Providing high-quality, cost-efficient care is a major strategic initiative of every health care organization. Today's health care environment is transparent; very competitive; and focused upon providing exceptional service, safety, and quality. Establishing an infusion alliance facilitates the achievement of organizational strategic initiatives, that is, increases patient throughput, decreases length of stay, prevents the occurrence of infusion-related complications, enhances customer satisfaction, and provides greater cost-efficiency. This article will discuss how to develop a financial analysis that promotes value and enhances the financial outcomes of an infusion alliance.

  14. Pump element for a tube pump

    DEFF Research Database (Denmark)

    2011-01-01

    The invention relates to a tube pump comprising a tube and a pump element inserted in the tube, where the pump element comprises a rod element and a first and a second non-return valve member positioned a distance apart on the rod element. The valve members are oriented in the same direction...... relative to the rod element so as to allow for a fluid flow in the tube through the first valve member, along the rod element, and through the second valve member. The tube comprises an at least partly flexible tube portion between the valve members such that a repeated deformation of the flexible tube...... portion acts to alternately close and open the valve members thereby generating a fluid flow through the tube. The invention further relates to a pump element comprising at least two non-return valve members connected by a rod element, and for insertion in an at least partly flexible tube in such tube...

  15. Pumping behavior of sputtering ion pump

    Energy Technology Data Exchange (ETDEWEB)

    Chou, T.S.; Bittner, J.; Schuchman, J.

    1991-12-31

    To optimize the design of a distributed ion pump (DIP) for the Superconducting X-Ray Lithography Source (SXLS) the stability of the rotating electron cloud at very high magnetic field beyond transition, must be re-examined. In this work the pumping speed and frequency spectrum of a DIP at various voltages (1 to 10 KV) and various magnetic fields (0.1 to 4 Tesla) are measured. Three cell diameters 10 mm, 5 mm and 2.5 mm, each 8 mm long, and with 3 or 4 mm gaps between anode and cathode are investigated. In this study both the titanium cathodes and the stainless steel anode plates are perforated with holes comparable in size to the anode cell diameters. Only the partially saturated pumping behavior is under investigation. The ultimate pressure and conditioning of the pump will be investigated at a later date when the stability criterion for the electron cloud is better understood.

  16. Pumping behavior of sputtering ion pump

    Energy Technology Data Exchange (ETDEWEB)

    Chou, T.S.; Bittner, J.; Schuchman, J.

    1991-01-01

    To optimize the design of a distributed ion pump (DIP) for the Superconducting X-Ray Lithography Source (SXLS) the stability of the rotating electron cloud at very high magnetic field beyond transition, must be re-examined. In this work the pumping speed and frequency spectrum of a DIP at various voltages (1 to 10 KV) and various magnetic fields (0.1 to 4 Tesla) are measured. Three cell diameters 10 mm, 5 mm and 2.5 mm, each 8 mm long, and with 3 or 4 mm gaps between anode and cathode are investigated. In this study both the titanium cathodes and the stainless steel anode plates are perforated with holes comparable in size to the anode cell diameters. Only the partially saturated pumping behavior is under investigation. The ultimate pressure and conditioning of the pump will be investigated at a later date when the stability criterion for the electron cloud is better understood.

  17. Volumetric expiratory high-resolution CT of the lung

    International Nuclear Information System (INIS)

    Nishino, Mizuki; Hatabu, Hiroto

    2004-01-01

    We developed a volumetric expiratory high-resolution CT (HRCT) protocol that provides combined inspiratory and expiratory volumetric imaging of the lung without increasing radiation exposure, and conducted a preliminary feasibility assessment of this protocol to evaluate diffuse lung disease with small airway abnormalities. The volumetric expiratory high-resolution CT increased the detectability of the conducting airway to the areas of air trapping (P<0.0001), and added significant information about extent and distribution of air trapping (P<0.0001)

  18. Adaptive controller for volumetric display of neuroimaging studies

    Science.gov (United States)

    Bleiberg, Ben; Senseney, Justin; Caban, Jesus

    2014-03-01

    Volumetric display of medical images is an increasingly relevant method for examining an imaging acquisition as the prevalence of thin-slice imaging increases in clinical studies. Current mouse and keyboard implementations for volumetric control provide neither the sensitivity nor specificity required to manipulate a volumetric display for efficient reading in a clinical setting. Solutions to efficient volumetric manipulation provide more sensitivity by removing the binary nature of actions controlled by keyboard clicks, but specificity is lost because a single action may change display in several directions. When specificity is then further addressed by re-implementing hardware binary functions through the introduction of mode control, the result is a cumbersome interface that fails to achieve the revolutionary benefit required for adoption of a new technology. We address the specificity versus sensitivity problem of volumetric interfaces by providing adaptive positional awareness to the volumetric control device by manipulating communication between hardware driver and existing software methods for volumetric display of medical images. This creates a tethered effect for volumetric display, providing a smooth interface that improves on existing hardware approaches to volumetric scene manipulation.

  19. A new infusion pathway intactness monitoring system.

    Science.gov (United States)

    Ogawa, Hidekuni; Yonezawa, Yoshiharu; Maki, Hiromichi; Ninomiya, Ishio; Sata, Koji; Hamada, Shingo; Caldwell, W Morton

    2006-01-01

    A new infusion pathway monitoring system has been developed for hospital and home use. The system consists of linear integrated circuits and a low-power 8-bit single chip microcomputer which constantly monitors the infusion pathway intactness. An AC (alternating current) voltage is induced on the patient's body by electrostatic coupling from the normal 100 volt, 60 Hz AC power line wiring field in the patient's room. The induced AC voltage can be recorded by a main electrode wrapped around the infusion polyvinyl chloride tube. A reference electrode is wrapped on the electrode to monitor the AC voltage around the main electrode. If the injection needle or infusion tube becomes detached, then the system detects changes in the induced AC voltages and alerts the nursing station, via the nurse call system or PHS (personal handy phone system).

  20. Effect of intravenous dexmedetomidine infusion on some ...

    African Journals Online (AJOL)

    Ahmed G. Yacout

    2011-12-17

    Dec 17, 2011 ... a Anaesthesia and Surgical Intensive Care Department, Faculty of Medicine, ... idine infusion in patients undergoing major abdominal surgery on stress .... the spinal cord, where drug activity attenuates nociceptive sig-.

  1. Carbon Nanotube Infused Launch Vehicle Structures

    Data.gov (United States)

    National Aeronautics and Space Administration — For the past 5 years Orbital ATK has been investing in, prototyping, and testing carbon nanotube infused composite structures to evaluate their impact on launch...

  2. A study on the pressure ripple characteristics in a bent-axis type oil hydraulic piston pump

    International Nuclear Information System (INIS)

    Cho, Ihn Sung; Jung, Jae Youn

    2013-01-01

    To improve the performance of a bent-axis type axial piston pump driven by tapered pistons, it is necessary to know the pressure ripple characteristics. The purpose of this paper is to understand the effect on the pressure ripple characteristics, and to predict by comparing experimental and theoretical analysis results. The simulation model of a bent-axis type axial piston pump is developed in the AMESim environment using the geometrical dimension, and the driving mechanism of the piston pump, such as the stroke of pump, the velocity of piston, the instantaneous volumetric flow, the overlap area of valve plate opening to cylinder bore, the angle of notch, and so on. The results show that theoretical analysis results of the bent-axis type axial piston pump by using the AMESim approximate the pressure ripple characteristic of the test pump, and through this, simulations can be obtained that predict the performance characteristics of a bentaxis type axial piston pump.

  3. Effects of intermediary reservoir in a two-stage impedance pump

    Directory of Open Access Journals (Sweden)

    Lee V. C.-C.

    2017-01-01

    Full Text Available Impedance pump is a simple valve-less pumping mechanism, which transport fluid through the mismatch of impedance in the system. A typical open-loop impedance pump consists of an elastic tube, connected to rigid tubing, where the rigid section is connected to a reservoir. Mismatch in impedance occurs when an asymmetrical periodic excitation is exerted on the elastic tube. Studies showed that sequential excitations on the elastic tube infers higher volumetric efficiency than a single excitation. This work studies the effects of an intermediary reservoir between two excitation points on an elastic tube. This study aims to shed some light on the steady state response and fluid motion within the intermediary reservoir; in which increased volumetric efficiency is demonstrated.

  4. Infusion Antihypoxants in Children with Critical Conditions

    Directory of Open Access Journals (Sweden)

    Yu. S. Aleksandrovich

    2014-01-01

    Full Text Available Hypoxia and mitochondrial damage are a key component of the pathogenesis and tanatogenesis of a critical condition, suggesting the need for its prevention and maximally rapid elimination. Objective: to analyze the efficacy and safety of infusion antihypoxants used in critically ill children from the results of researches. Materials and methods. Available investigations dealing with infusion therapy in children and papers on the use of infusion antihypoxants in adults in 2005 to 2013 were sought in the medical databases PubMed and Cochrane Library with their free availability and analyzed. Results. The analysis included 70 trials. The pathophysiology and pathobiochemistry of hypoxia in critically ill children are given; the current principles of its correction by infusion therapy are considered in detail. Particular emphasis is placed on trials evaluating the efficacy and safety of succinic acid solutions in children. Main indications for and contraindications to their use are demonstrated. Conclusion. The use of Krebs cycle substrate-based infusion antihypoxants (malate, succinate is an effective and promising procedure for the intensive therapy and correction of hypoxia in both adults and children with critical conditions. Considering the fact that papers on the use of infusion antihypoxants in children are scanty, there is a need for further investigations. 

  5. Electrokinetic pumps and actuators

    International Nuclear Information System (INIS)

    Phillip M. Paul

    2000-01-01

    Flow and ionic transport in porous media are central to electrokinetic pumping as well as to a host of other microfluidic devices. Electrokinetic pumping provides the ability to create high pressures (to over 10,000 psi) and high flow rates (over 1 mL/min) with a device having no moving parts and all liquid seals. The electrokinetic pump (EKP) is ideally suited for applications ranging from a high pressure integrated pump for chip-scale HPLC to a high flow rate integrated pump for forced liquid convection cooling of high-power electronics. Relations for flow rate and current fluxes in porous media are derived that provide a basis for analysis of complex microfluidic systems as well as for optimization of electrokinetic pumps

  6. Electrokinetic pumps and actuators

    Energy Technology Data Exchange (ETDEWEB)

    Phillip M. Paul

    2000-03-01

    Flow and ionic transport in porous media are central to electrokinetic pumping as well as to a host of other microfluidic devices. Electrokinetic pumping provides the ability to create high pressures (to over 10,000 psi) and high flow rates (over 1 mL/min) with a device having no moving parts and all liquid seals. The electrokinetic pump (EKP) is ideally suited for applications ranging from a high pressure integrated pump for chip-scale HPLC to a high flow rate integrated pump for forced liquid convection cooling of high-power electronics. Relations for flow rate and current fluxes in porous media are derived that provide a basis for analysis of complex microfluidic systems as well as for optimization of electrokinetic pumps.

  7. Volumetric visualization of anatomy for treatment planning

    International Nuclear Information System (INIS)

    Pelizzari, Charles A.; Grzeszczuk, Robert; Chen, George T. Y.; Heimann, Ruth; Haraf, Daniel J.; Vijayakumar, Srinivasan; Ryan, Martin J.

    1996-01-01

    Purpose: Delineation of volumes of interest for three-dimensional (3D) treatment planning is usually performed by contouring on two-dimensional sections. We explore the usage of segmentation-free volumetric rendering of the three-dimensional image data set for tumor and normal tissue visualization. Methods and Materials: Standard treatment planning computed tomography (CT) studies, with typically 5 to 10 mm slice thickness, and spiral CT studies with 3 mm slice thickness were used. The data were visualized using locally developed volume-rendering software. Similar to the method of Drebin et al., CT voxels are automatically assigned an opacity and other visual properties (e.g., color) based on a probabilistic classification into tissue types. Using volumetric compositing, a projection into the opacity-weighted volume is produced. Depth cueing, perspective, and gradient-based shading are incorporated to achieve realistic images. Unlike surface-rendered displays, no hand segmentation is required to produce detailed renditions of skin, muscle, or bony anatomy. By suitable manipulation of the opacity map, tissue classes can be made transparent, revealing muscle, vessels, or bone, for example. Manually supervised tissue masking allows irrelevant tissues overlying tumors or other structures of interest to be removed. Results: Very high-quality renditions are produced in from 5 s to 1 min on midrange computer workstations. In the pelvis, an anteroposterior (AP) volume rendered view from a typical planning CT scan clearly shows the skin and bony anatomy. A muscle opacity map permits clear visualization of the superficial thigh muscles, femoral veins, and arteries. Lymph nodes are seen in the femoral triangle. When overlying muscle and bone are cut away, the prostate, seminal vessels, bladder, and rectum are seen in 3D perspective. Similar results are obtained for thorax and for head and neck scans. Conclusion: Volumetric visualization of anatomy is useful in treatment

  8. Detection of pump degradation

    International Nuclear Information System (INIS)

    Greene, R.H.; Casada, D.A.; Ayers, C.W.

    1995-08-01

    This Phase II Nuclear Plant Aging Research study examines the methods of detecting pump degradation that are currently employed in domestic and overseas nuclear facilities. This report evaluates the criteria mandated by required pump testing at U.S. nuclear power plants and compares them to those features characteristic of state-of-the-art diagnostic programs and practices currently implemented by other major industries. Since the working condition of the pump driver is crucial to pump operability, a brief review of new applications of motor diagnostics is provided that highlights recent developments in this technology. The routine collection and analysis of spectral data is superior to all other technologies in its ability to accurately detect numerous types and causes of pump degradation. Existing ASME Code testing criteria do not require the evaluation of pump vibration spectra but instead overall vibration amplitude. The mechanical information discernible from vibration amplitude analysis is limited, and several cases of pump failure were not detected in their early stages by vibration monitoring. Since spectral analysis can provide a wealth of pertinent information concerning the mechanical condition of rotating machinery, its incorporation into ASME testing criteria could merit a relaxation in the monthly-to-quarterly testing schedules that seek to verify and assure pump operability. Pump drivers are not included in the current battery of testing. Operational problems thought to be caused by pump degradation were found to be the result of motor degradation. Recent advances in nonintrusive monitoring techniques have made motor diagnostics a viable technology for assessing motor operability. Motor current/power analysis can detect rotor bar degradation and ascertain ranges of hydraulically unstable operation for a particular pump and motor set. The concept of using motor current or power fluctuations as an indicator of pump hydraulic load stability is presented

  9. Detection of pump degradation

    Energy Technology Data Exchange (ETDEWEB)

    Greene, R.H.; Casada, D.A.; Ayers, C.W. [and others

    1995-08-01

    This Phase II Nuclear Plant Aging Research study examines the methods of detecting pump degradation that are currently employed in domestic and overseas nuclear facilities. This report evaluates the criteria mandated by required pump testing at U.S. nuclear power plants and compares them to those features characteristic of state-of-the-art diagnostic programs and practices currently implemented by other major industries. Since the working condition of the pump driver is crucial to pump operability, a brief review of new applications of motor diagnostics is provided that highlights recent developments in this technology. The routine collection and analysis of spectral data is superior to all other technologies in its ability to accurately detect numerous types and causes of pump degradation. Existing ASME Code testing criteria do not require the evaluation of pump vibration spectra but instead overall vibration amplitude. The mechanical information discernible from vibration amplitude analysis is limited, and several cases of pump failure were not detected in their early stages by vibration monitoring. Since spectral analysis can provide a wealth of pertinent information concerning the mechanical condition of rotating machinery, its incorporation into ASME testing criteria could merit a relaxation in the monthly-to-quarterly testing schedules that seek to verify and assure pump operability. Pump drivers are not included in the current battery of testing. Operational problems thought to be caused by pump degradation were found to be the result of motor degradation. Recent advances in nonintrusive monitoring techniques have made motor diagnostics a viable technology for assessing motor operability. Motor current/power analysis can detect rotor bar degradation and ascertain ranges of hydraulically unstable operation for a particular pump and motor set. The concept of using motor current or power fluctuations as an indicator of pump hydraulic load stability is presented.

  10. Thermomechanical piston pump development

    Science.gov (United States)

    Sabelman, E. E.

    1971-01-01

    A thermally powered reciprocating pump has been devised to replace or augment an electric pump for the transport of temperature-control fluid on the Thermoelectric Outer Planet Spacecraft (TOPS). The thermally powered pump operates cyclically by extracting heat energy from the fluid by means of a vapor-pressure expansion system and by using the heat to perform the mechanical work of pumping. A feasibility test unit has been constructed to provide an output of 7 cu in during a 10- to 100-second cycle. It operates with a fluid input temperature of 200 to 300 F and a heat sink temperature of 0 to 30 F.

  11. Pumps for nuclear industry

    International Nuclear Information System (INIS)

    Tanguy, L.

    1978-01-01

    In order to meet the requirements of nuclear industry for the transfer of corrosive, toxic, humidity sensitive or very pure gases, different types of pumps were developped and commercialized. Their main characteristics are to prevent pollution of the transfered fluid by avoiding any contact between this fluid and the lubricated parts of the machine, and to prevent a contamination of the atmosphere or of the fluid by a total tightness. Patellar pumps have been particularly developped because the metallic bellows are quite reliable and resistant in this configuration. Two types are described: patellar pumps without friction and barrel pumps whose pistons are provided with rings sliding in the cylinders without lubrication [fr

  12. Pump safety device

    International Nuclear Information System (INIS)

    Timmermans, Francis; Vandervorst, Jean.

    1981-01-01

    Safety device for longitudinally leak proofing the shaft of a pump in the event of the fracture of the dynamic seal separating the pump fluid high pressure chamber from the low pressure chamber. It is designed for fitting to the primary pumps of nuclear reactors. It includes a hollow cyclindrical piston located coaxially around the pump shaft and normally housed in a chamber provided for this purpose in the fixed housing of the dynamic seal, and means for moving this piston coaxially so as to compress a safety O ring between the shaft and the piston in the event of the dynamic seal failing [fr

  13. Optically pumped atoms

    CERN Document Server

    Happer, William; Walker, Thad

    2010-01-01

    Covering the most important knowledge on optical pumping of atoms, this ready reference is backed by numerous examples of modelling computation for optical pumped systems. The authors show for the first time that modern scientific computing software makes it practical to analyze the full, multilevel system of optically pumped atoms. To make the discussion less abstract, the authors have illustrated key points with sections of MATLAB codes. To make most effective use of contemporary mathematical software, it is especially useful to analyze optical pumping situations in the Liouville spa

  14. Detection of pump degradation

    International Nuclear Information System (INIS)

    Casada, D.

    1995-01-01

    There are a variety of stressors that can affect the operation of centrifugal pumps. Although these general stressors are active in essentially all centrifugal pumps, the stressor level and the extent of wear and degradation can vary greatly. Parameters that affect the extent of stressor activity are manifold. In order to assure the long-term operational readiness of a pump, it is important to both understand the nature and magnitude of the specific degradation mechanisms and to monitor the performance of the pump. The most commonly applied method of monitoring the condition of not only pumps, but rotating machinery in general, is vibration analysis. Periodic or continuous special vibration analysis is a cornerstone of most pump monitoring programs. In the nuclear industry, non-spectral vibration monitoring of safety-related pumps is performed in accordance with the ASME code. Pump head and flow rate are also monitored, per code requirements. Although vibration analysis has dominated the condition monitoring field for many years, there are other measures that have been historically used to help understand pump condition; advances in historically applied technologies and developing technologies offer improved monitoring capabilities. The capabilities of several technologies (including vibration analysis, dynamic pressure analysis, and motor power analysis) to detect the presence and magnitude of both stressors and resultant degradation are discussed

  15. Champagne Heat Pump

    Science.gov (United States)

    Jones, Jack A.

    2004-01-01

    The term champagne heat pump denotes a developmental heat pump that exploits a cycle of absorption and desorption of carbon dioxide in an alcohol or other organic liquid. Whereas most heat pumps in common use in the United States are energized by mechanical compression, the champagne heat pump is energized by heating. The concept of heat pumps based on other absorption cycles energized by heat has been understood for years, but some of these heat pumps are outlawed in many areas because of the potential hazards posed by leakage of working fluids. For example, in the case of the water/ammonia cycle, there are potential hazards of toxicity and flammability. The organic-liquid/carbon dioxide absorption/desorption cycle of the champagne heat pump is similar to the water/ammonia cycle, but carbon dioxide is nontoxic and environmentally benign, and one can choose an alcohol or other organic liquid that is also relatively nontoxic and environmentally benign. Two candidate nonalcohol organic liquids are isobutyl acetate and amyl acetate. Although alcohols and many other organic liquids are flammable, they present little or no flammability hazard in the champagne heat pump because only the nonflammable carbon dioxide component of the refrigerant mixture is circulated to the evaporator and condenser heat exchangers, which are the only components of the heat pump in direct contact with air in habitable spaces.

  16. Subcutaneous insulin infusion: change in basal infusion rate has no immediate effect on insulin absorption rate

    International Nuclear Information System (INIS)

    Hildebrandt, P.; Birch, K.; Jensen, B.M.; Kuehl, C.

    1986-01-01

    Eight insulin-dependent diabetic patients were simultaneously given subcutaneous infusions (1.12 IU/h each) of 125 I-labeled Actrapid insulin in each side of the abdominal wall. After 24 h of infusion, the size of the infused insulin depots was measured by external counting for 5 h. The basal infusion rate was then doubled in one side and halved in the other for the next 4 h. Finally, 1.12 IU/h of insulin was given in both sides of the abdominal wall for an additional 3 h. The changes in the size of the depots were measured, and the absorption rates for each hour were calculated. During the first 5 h of infusion, the depot size was almost constant (approximately 5 IU) with an absorption rate that equaled the infusion rate. Doubling the infusion rate led to a significant increase in depot size, but the absorption rate remained unchanged for the first 3 h, and only thereafter was a significant increase seen. When the infusion rate was reduced to the initial 1.12 IU/h, the absorption rate remained elevated during the next 3 h. Correspondingly, when the infusion rate was decreased, the depot size also decreased, but the absorption rate remained unchanged for the first 3 h. The results show that a change in the basal insulin infusion rate does not lead to any immediate change in the insulin absorption rate. This should be considered when planning an insulin-infusion program that includes alteration(s) in the basal-rate setting

  17. Determination of Uncertainty for a One Milli Litre Volumetric Pipette

    International Nuclear Information System (INIS)

    Torowati; Asminar; Rahmiati; Arif-Sasongko-Adi

    2007-01-01

    An observation had been conducted to determine the uncertainty of volumetric pipette. The uncertainty was determined from data obtained from a determine process which used method of gravimetry. Calculation result from an uncertainty of volumetric pipette the confidence level of 95% and k=2. (author)

  18. Performance of Wind Pump Prototype

    African Journals Online (AJOL)

    Mulu

    Mekelle University, Mekelle, Ethiopia (*mul_at@yahoo.com). ABSTRACT. A wind ... balanced rotor power and reciprocating pump, hence did not consider the effect of pump size. ... Keywords: Wind pump, Windmill, Performance testing, Pump efficiency, Pump discharge, ... Unfortunately, in rural places, where the houses are.

  19. The properties of an improvised piston pump for the rapid delivery of intravenous fluids.

    Science.gov (United States)

    Smart, C M; Primrose, C W; Peters, A L; Speirits, E J

    2014-02-01

    To maximise the effect of a small fluid load, it is occasionally desirable to bolus manually with multiple depressions of a large-capacity syringe. This is usually achieved by placing the syringe on the side port of a three-way tap. We modified this technique by placing two-one-way valves in line with the three-way tap, effectively creating a piston pump, the infusion rates via which we compared with those achieved by an inflatable pressure-infuser in a simulated resuscitation. Fluid flow was faster using the piston pump than with the pressure-infuser (mean (SD) time to infuse 2000 ml saline 0.9% via a 16-G cannula 352 (10) s vs 495 (19) s, respectively, p piston pump appears to have potential for both tight control of fluid delivery and major high-volume resuscitation. The lightweight nature of the pump and its lack of reliance on gravity may also make it suitable for the pre-hospital setting. © 2014 The Association of Anaesthetists of Great Britain and Ireland.

  20. Glucose Pump Test can be Used to Measure Blood Flow Rate of ...

    African Journals Online (AJOL)

    The aim of study is to determine whether glucose pump test (GPT) is used for surveillance of native AV fistulas by using Doppler US as reference. Methods: In 93 chronic hemodialysis patients with native AV fistula, blood flow rates were measured by Doppler US and GPT. For GPT, glucose was infused to 16 mL/min by ...

  1. The effects of design parameters on vortex diode pump performance, 2

    International Nuclear Information System (INIS)

    Yoshitomi, Hideki; Koizumi, Tadao; Muroyama, Kenichi; Wada, Tsutomu.

    1989-01-01

    A fluidic pump with two vortex diodes is a new technology for transporting dangerous corrosive fluids without the use of moving parts. The pump can be connected with the discharge tank through series and cascade connections. In the previous report, we described the fundamentals and design criteria of the pump for the series connection case. This study has been performed with the same object as the previous work for the case of cascade connection. First, we present the basic pump characteristics with some dimensionless performance factors by analyzing the pump model. Then, the effects of the cylinder volumetric coefficient, driving pressure, suction-diode-to-delivery-diode-passage-area ratio and reverse-flow-to-forward-flow-resistance ratio of the vortex diode are investigated. As a result, the characteristic difference between series and cascade connections is clarified. Basic ways to decide the value of each performance factor are suggested. (author)

  2. Detection of pump degradation

    International Nuclear Information System (INIS)

    Casada, D.

    1994-01-01

    There are a variety of stressors that can affect the operation of centrifugal pumps. Although these general stressors are active in essentially all centrifugal pumps, the stressor level and the extent of wear and degradation can vary greatly. Parameters that affect the extent of stressor activity are manifold. In order to assure the long-term operational readiness of a pump, it is important to both understand the nature and magnitude of the specific degradation mechanisms and to monitor the performance of the pump. The most commonly applied method of monitoring the condition of not only pumps, but rotating machinery in general, is vibration analysis. Periodic or continuous spectral vibration analysis is a cornerstone of most pump monitoring programs. In the nuclear industry, non-spectral vibration monitoring of safety-related pumps is performed in accordance with the ASME code. Although vibration analysis has dominated the condition monitoring field for many years, there are other measures that have been historically used to help understand pump condition: advances in historically applied technologies and developing technologies offer improved monitoring capabilities. The capabilities of several technologies (including vibration analysis, dynamic pressure analysis, and motor power analysis) to detect the presence and magnitude of both stressors and resultant degradation are discussed

  3. Normetex Pump Alternatives Study

    International Nuclear Information System (INIS)

    Clark, Elliot A.

    2013-01-01

    A mainstay pump for tritium systems, the Normetex scroll pump, is currently unavailable because the Normetex company went out of business. This pump was an all-metal scroll pump that served tritium processing facilities very well. Current tritium system operators are evaluating replacement pumps for the Normetex pump and for general used in tritium service. An all-metal equivalent alternative to the Normetex pump has not yet been identified. 1. The ideal replacement tritium pump would be hermetically sealed and contain no polymer components or oils. Polymers and oils degrade over time when they contact ionizing radiation. 2. Halogenated polymers (containing fluorine, chlorine, or both) and oils are commonly found in pumps. These materials have many properties that surpass those of hydrocarbon-based polymers and oils, including thermal stability (higher operating temperature) and better chemical resistance. Unfortunately, they are less resistant to degradation from ionizing radiation than hydrocarbon-based materials (in general). 3. Polymers and oils can form gaseous, condensable (HF, TF), liquid, and solid species when exposed to ionizing radiation. For example, halogenated polymers form HF and HCl, which are extremely corrosive upon reaction with water. If a pump containing polymers or oils must be used in a tritium system, the system must be designed to be able to process the unwanted by-products. Design features to mitigate degradation products include filters and chemical or physical traps (eg. cold traps, oil traps). 4. Polymer components can work in tritium systems, but must be replaced regularly. Polymer components performance should be monitored or be regularly tested, and regular replacement of components should be viewed as an expected normal event. A radioactive waste stream must be established to dispose of used polymer components and oil with an approved disposal plan developed based on the facility location and its regulators. Polymers have varying

  4. Vocal fold submucosal infusion technique in phonomicrosurgery.

    Science.gov (United States)

    Kass, E S; Hillman, R E; Zeitels, S M

    1996-05-01

    Phonomicrosurgery is optimized by maximally preserving the vocal fold's layered microstructure (laminae propriae). The technique of submucosal infusion of saline and epinephrine into the superficial lamina propria (SLP) was examined to delineate how, when, and why it was helpful toward this surgical goal. A retrospective review revealed that the submucosal infusion technique was used to enhance the surgery in 75 of 152 vocal fold procedures that were performed over the last 2 years. The vocal fold epithelium was noted to be adherent to the vocal ligament in 29 of the 75 cases: 19 from previous surgical scarring, 4 from cancer, 3 from sulcus vocalis, 2 from chronic hemorrhage, and 1 from radiotherapy. The submucosal infusion technique was most helpful when the vocal fold epithelium required resection and/or when extensive dissection in the SLP was necessary. The infusion enhanced the surgery by vasoconstriction of the microvasculature in the SLP, which improved visualization during cold-instrument tangential dissection. Improved visualization facilitated maximal preservation of the SLP, which is necessary for optimal pliability of the overlying epithelium. The infusion also improved the placement of incisions at the perimeter of benign, premalignant, and malignant lesions, and thereby helped preserve epithelium uninvolved by the disorder.

  5. Circulation pump mounting

    International Nuclear Information System (INIS)

    Skalicky, A.

    1976-01-01

    The suspension is described of nuclear reactor circulating pumps enabling their dilatation with a minimum reverse force consisting of spacing rods supported with one end in the anchor joints and provided with springs and screw joints engaging the circulating pump shoes. The spacing rods are equipped with side vibration dampers anchored in the shaft side wall and on the body of the circulating pump drive body. The negative reverse force F of the spacing rods is given by the relation F=Q/l.y, where Q is the weight of the circulating pump, l is the spatial distance between the shoe joints and anchor joints, and y is the deflection of the circulating pump vertical axis from the mean equilibrium position. The described suspension is advantageous in that that the reverse force for the deflection from the mean equilibrium position is minimal, dynamic behaviour is better, and construction costs are lower compared to suspension design used so far. (J.B.)

  6. Helmholtz resonance in a piezoelectric–hydraulic pump-based hybrid actuator

    International Nuclear Information System (INIS)

    Kim, Gi-Woo; Wang, K W

    2011-01-01

    This paper demonstrates that a hydraulically acting Helmholtz resonator can exist in a piezoelectric–hydraulic pump (PHP) based hybrid actuator, which in turn affects the volumetric efficiency of the PHP. The simulation and experimental results illustrate the effect of Helmholtz resonance on the flow rate performance of the PHP. The study also shows how to shift the Helmholtz resonant frequency to a higher value through changing parameters such as the cylinder diameter and the effective bulk modulus of the working fluid, which will improve the volumetric efficiency and broaden the operating frequency range of the PHP actuator

  7. BWR series pump recirculation system

    International Nuclear Information System (INIS)

    Dillmann, C.W.

    1992-01-01

    This patent describes a recirculation system for driving reactor coolant water contained in an annular downcomer defined between a boiling water reactor vessel and a reactor core spaced radially inwardly therefrom. It comprises a plurality of circumferentially spaced second pumps disposed in the downcomer, each including an inlet for receiving from the downcomer a portion of the coolant water as pump inlet flow, and an outlet for discharging the pump inlet flow pressurized in the second pump as pump outlet flow; and means for increasing pressure of the pump inlet flow at the pump inlet including a first pump disposed in series flow with the second pump for first receiving the pump inlet flow from the downcomer and discharging to the second pump inlet flow pressurized in the first pump

  8. High pressure liquid gas pump

    Science.gov (United States)

    Acres, R. L.

    1972-01-01

    Design and development of two types of pumps for handling liquefied gases are discussed. One pump uses mechanical valve shift and other uses pneumatic valve shift. Illustrations of pumps are provided and detailed description of operation is included.

  9. Evaluation of the performance of elastomeric pumps in practice: are we under-delivering on chemotherapy treatments?

    Science.gov (United States)

    Salman, Dahlia; Biliune, Jurga; Kayyali, Reem; Ashton, Jane; Brown, Peter; McCarthy, Tim; Vikman, Elin; Barton, Stephen; Swinden, Julian; Nabhani-Gebara, Shereen

    2017-12-01

    Elastomeric pumps are widely used to facilitate ambulatory chemotherapy, and studies have shown that they are safe and well received by patients. Despite these advantages, their end of infusion time can fluctuate significantly. The aim of this research was to observe the performance of these pumps in real practice and to evaluate patients' satisfaction. This was a two-phase study conducted at three cancer units over 6 months. Phase-1 was an observational study recording the status of pumps at the scheduled disconnection time and noting remaining volume of infusion. Phase-2 was a survey of patients and their perception/satisfaction. Ethical approval was granted. A total of 92 cases were observed covering 50 cases disconnected at hospital and 42 disconnected at home. The infusion in 40% of hospital disconnection cases was slow, with patients arriving at hospital with unfinished pumps; 58% of these had an estimated remaining volume which exceeded 10 mL with 35% exceeded 20 mL. In 73% of these cases, and regardless of the remaining volume, the patient was disconnected and the pump was discarded. The performance of pumps varied, which affected nurse workload and patients' waiting-times. A smart system is an option to monitor the performance of pumps and to predict their accuracy.

  10. A new venous infusion pathway monitoring system.

    Science.gov (United States)

    Maki, Hiromichi; Yonezawa, Yoshiharu; Ogawa, Hidekuni; Ninomiya, Ishio; Sata, Koji; Hamada, Shingo; Caldwell, W Morton

    2007-01-01

    A new infusion catheter pathway monitoring system employing linear integrated circuits and a low-power 8-bit single chip microcomputer has been developed for hospital and home use. The sensor consists of coaxial three-layer conductive tapes wrapped around the polyvinyl chloride infusion tube. The inner tape is the main electrode, which records an AC (alternating current) voltage induced on the patient's body by electrostatic coupling from the normal 100 volt, 60 Hz AC power line wiring field in the patient's room. The outside tape layer is a reference electrode to monitor the AC voltage around the main electrode. The center tape layer is connected to system ground and functions as a shield. The microcomputer calculates the ratio of the induced AC voltages recorded by the main and reference electrodes and if the ratio indicates a detached infusion, alerts the nursing station, via the nurse call system or low transmitting power mobile phone.

  11. Design of Infusion Schemes for Neuroreceptor Imaging

    DEFF Research Database (Denmark)

    Feng, Ling; Svarer, Claus; Madsen, Karine

    2016-01-01

    for bolus infusion (BI) or programmed infusion (PI) experiments. Steady-state quantitative measurements can be made with one short scan and venous blood samples. The GABAA receptor ligand [(11)C]Flumazenil (FMZ) was chosen for this purpose, as it lacks a suitable reference region. Methods. Five bolus [(11)C...... state was attained within 40 min, which was 8 min earlier than the optimal BI (B/I ratio = 55 min). Conclusions. The system can design both BI and PI schemes to attain steady state rapidly. For example, subjects can be [(11)C]FMZ-PET scanned after 40 min of tracer infusion for 40 min with venous...

  12. Forearm metabolism during infusion of adrenaline

    DEFF Research Database (Denmark)

    Simonsen, L; Stefl, B; Bülow, J

    2000-01-01

    Human skeletal muscle metabolism is often investigated by measurements of substrate fluxes across the forearm. To evaluate whether the two forearms give the same metabolic information, nine healthy subjects were studied in the fasted state and during infusion of adrenaline. Both arms were...... catheterized in a cubital vein in the retrograde direction. A femoral artery was catheterized for blood sampling, and a femoral vein for infusion of adrenaline. Forearm blood flow was measured by venous occlusion strain-gauge plethysmography. Forearm subcutaneous adipose tissue blood flow was measured...... by the local 133Xe washout method. Metabolic fluxes were calculated as the product of forearm blood flow and a-v differences of metabolite concentrations. After baseline measurements, adrenaline was infused at a rate of 0.3 nmol kg-1 min-1. No difference in the metabolic information obtained in the fasting...

  13. Numerical Modeling of Surface and Volumetric Cooling using Optimal T- and Y-shaped Flow Channels

    Science.gov (United States)

    Kosaraju, Srinivas

    2017-11-01

    The layout of T- and V-shaped flow channel networks on a surface can be optimized for minimum pressure drop and pumping power. The results of the optimization are in the form of geometric parameters such as length and diameter ratios of the stem and branch sections. While these flow channels are optimized for minimum pressure drop, they can also be used for surface and volumetric cooling applications such as heat exchangers, air conditioning and electronics cooling. In this paper, an effort has been made to study the heat transfer characteristics of multiple T- and Y-shaped flow channel configurations using numerical simulations. All configurations are subjected to same input parameters and heat generation constraints. Comparisons are made with similar results published in literature.

  14. Chemical Stability of Telavancin in Elastomeric Pumps.

    Science.gov (United States)

    Sand, Patrick; Aladeen, Traci; Kirkegaard, Paul; LaChance, Dennis; Slover, Christine

    2015-12-01

    VIBATIV is a once-daily, injectable lipoglycopeptide antibiotic approved in the U.S. for the treatment of hospital-acquired and ventilator-associated bacterial pneumonia (HABP/VABP) caused by susceptible isolates of Staphylococcus aureus when alternative treatments are not suitable. In addition, VIBATIV is approved in the U.S. for the treatment of adult patients with complicated skin & skin structure infections (cSSSI) caused by susceptible isolates of Gram-positive bacteria, including Staphylococcus aureus, both methicillin-susceptible (MSSA) and methicillin-resistant (MRSA) strains. To evaluate the chemical stability of telavancin (Vibativ; Theravance Biopharma US, Inc, Northbrook, Illinois), a lipoglycopeptide antibiotic with activity against methicillin-resistant Staphylococcus aureus, in 2 types of elastomeric pumps, the Intermate Infusion System (Baxter International Inc) and the Homepump Eclipse (I-Flow Corporation). Different sizes of the Baxter (Ontario, Canada) (105 mL and 275 mL) and I-Flow (Stoughton, Massachusetts) (100 mL and 250 mL) pumps were compared with glass controls. The telavancin drug product was reconstituted and diluted to concentrations of 0.6 mg/mL and 8.0 mg/mL using either 0.9% saline, 5% dextrose in water, or sterilized water for injection (0.6 mg/mL telavancin) or saline (8.0 mg/mL telavancin) followed by Ringer's Lactate solution. Pumps were filled and stored at 2°C to 8°C, protected from light. Aliquots from both pump types and for all telavancin reconstitution/dilution schemes and concentrations were taken over a period of 8 days and analyzed for appearance, pH, telavancin concentration and purity, and degradation products. The pH of all pump solutions remained consistent throughout the 8-day analysis period, within a range of 4.6 to 5.7 for the 0.6 mg/mL and 4.4 to 4.9 for the 8.0 mg/mL telavancin solutions. There was no significant change in the chromatographic purity for any of the pump solutions examined. All decreases in

  15. Theoretical study of heat pump system using CO2/dimethylether as refrigerant

    Directory of Open Access Journals (Sweden)

    Fan Xiao-Wei

    2013-01-01

    Full Text Available Nowadays, HCFC22 is widely used in heat pump systems in China, which should be phased out in the future. Thus, eco-friendly mixture CO2/dimethylether is proposed to replace HCFC22. Compared with pure CO2 and pure dimethylether, the mixture can reduce the heat rejection pressure, and suppress the flammability and explosivity of pure dimethylether. According to the Chinese National Standards on heat pump water heater and space heating system, performances of the subcritical heat pump system are discussed and compared with those of the HCFC22 system. It can be concluded that CO2 /dimethylether mixture works efficiently as a refrigerant for heat pumps with a large heat-sink temperature rise. When mass fraction of dimethylether is increased, the heat rejection pressure is reduced. Under the nominal working condition, there is an optimal mixture mass fraction of 28/72 of CO2/dimethylether for water heater application under conventional condensation pressure, 3/97 for space heating application. For water heater application, both the heating coefficient of performance and volumetric heating capacity increase by 17.90% and 2.74%, respectively, compared with those of HCFC22 systems. For space heating application, the heating coefficient of performance increases by 8.44% while volumetric heating capacity decreases by 34.76%, compared with those of HCFC22 systems. As the superheat degree increases, both the heating coefficient of performance and volumetric heating capacity tend to decrease.

  16. Pumping machinery theory and practice

    CERN Document Server

    Badr, Hassan M

    2014-01-01

    Pumping Machinery Theory and Practice comprehensively covers the theoretical foundation and applications of pumping machinery. Key features: Covers characteristics of centrifugal pumps, axial flow pumps and displacement pumpsConsiders pumping machinery performance and operational-type problemsCovers advanced topics in pumping machinery including multiphase flow principles, and two and three-phase flow pumping systemsCovers different methods of flow rate control and relevance to machine efficiency and energy consumptionCovers different methods of flow rate control and relevance to machine effi

  17. Electromagnetic pump technology

    International Nuclear Information System (INIS)

    Prabhakar, R.

    1994-01-01

    Fast Breeder Reactors have an important role to play in our nuclear power programme. Liquid metal sodium is used as the coolant for removing fission heat generated in fast reactors and a distinctive physical property of sodium is its high electrical conductivity. This enables application of electromagnetic (EM) pumps, working on same principle as electric motors, for pumping liquid sodium. Due to its lower efficiency as compared to centrifugal pumps, use of EM pumps has been restricted to reactor auxiliary circuits and experimental facilities. As part of our efforts to manufacture fast reactor components indigenously, work on the development of two types of EM pumps namely flat linear induction pump (FLIP) and annular linear induction pump (ALIP) has been undertaken. Design procedures based on an equivalent circuit approach have been established and results from testing a 5.6 x 10E-3 Cum/s (20 Cum/h) FLIP in a sodium loop were used to validate the procedure. (author). 7 refs., 6 figs

  18. Soil volumetric water content measurements using TDR technique

    Directory of Open Access Journals (Sweden)

    S. Vincenzi

    1996-06-01

    Full Text Available A physical model to measure some hydrological and thermal parameters in soils will to be set up. The vertical profiles of: volumetric water content, matric potential and temperature will be monitored in different soils. The volumetric soil water content is measured by means of the Time Domain Reflectometry (TDR technique. The result of a test to determine experimentally the reproducibility of the volumetric water content measurements is reported together with the methodology and the results of the analysis of the TDR wave forms. The analysis is based on the calculation of the travel time of the TDR signal in the wave guide embedded in the soil.

  19. Air-lift pumps characteristics under two-phase flow conditions

    International Nuclear Information System (INIS)

    Kassab, Sadek Z.; Kandil, Hamdy A.; Warda, Hassan A.; Ahmed, Wael H.

    2009-01-01

    Air-lift pumps are finding increasing use where pump reliability and low maintenance are required, where corrosive, abrasive, or radioactive fluids in nuclear applications must be handled and when a compressed air is readily available as a source of a renewable energy for water pumping applications. The objective of the present study is to evaluate the performance of a pump under predetermined operating conditions and to optimize the related parameters. For this purpose, an air-lift pump was designed and tested. Experiments were performed for nine submergence ratios, and three risers of different lengths with different air injection pressures. Moreover, the pump was tested under different two-phase flow patterns. A theoretical model is proposed in this study taking into account the flow patterns at the best efficiency range where the pump is operated. The present results showed that the pump capacity and efficiency are functions of the air mass flow rate, submergence ratio, and riser pipe length. The best efficiency range of the air-lift pumps operation was found to be in the slug and slug-churn flow regimes. The proposed model has been compared with experimental data and the most cited models available. The proposed model is in good agreement with experimental results and found to predict the liquid volumetric flux for different flow patterns including bubbly, slug and churn flow patterns

  20. Runaway electron beam control for longitudinally pumped metal vapor lasers

    Science.gov (United States)

    Kolbychev, G. V.; Kolbycheva, P. D.

    1995-08-01

    Physics and techniques for producing of the pulsed runaway electron beams are considered. The main obstacle for increasing electron energies in the beams is revealed to be a self- breakdown of the e-gun's gas-filled diode. Two methods to suppress the self-breakdown and enhance the volumetric discharge producing the e-beam are offered and examined. Each of them provides 1.5 fold increase of the ceiling potential on the gun. The methods also give the ways to control several guns simultaneously. Resulting in the possibility of realizing the powerful longitudinal pumping of metal-vapor lasers on self-terminated transitions of atoms or ions.

  1. Effect of steel and teflon infusion catheters on subcutaneous adipose tissue blood flow and infusion counter pressure in humans

    DEFF Research Database (Denmark)

    Højbjerre, Lise; Skov-Jensen, Camilla; Kaastrup, Peter

    2009-01-01

    BACKGROUND: Subcutaneous tissue is an important target for drug deposition or infusion. A local trauma may induce alterations in local microcirculation and diffusion barriers with consequences for drug bioavailability. We examined the influence of infusion catheters' wear time on local...... microcirculation and infusion counter pressure. METHODS: One steel catheter and one Teflon (Dupont, Wilmington, DE) catheter were inserted in subcutaneous, abdominal adipose tissue (SCAAT) in 10 healthy, lean men. The catheters were infused with isotonic saline at a rate of 10 microL/h for 48 h. Another steel...... catheter and a Teflon catheter were inserted contralateral to the previous catheters after 48 h. The infusion counter pressure was measured during a basal infusion rate followed by a bolus infusion. The measurements during a basal rate infusion were repeated after the bolus infusion. Adipose tissue blood...

  2. Absorption heat pumps

    International Nuclear Information System (INIS)

    Formigoni, C.

    1998-01-01

    A brief description of the difference between a compression and an absorption heat pump is made, and the reasons why absorption systems have spread lately are given. Studies and projects recently started in the field of absorption heat pumps, as well as criteria usually followed in project development are described. An outline (performance targets, basic components) of a project on a water/air absorption heat pump, running on natural gas or LPG, is given. The project was developed by the Robur Group as an evolution of a water absorption refrigerator operating with a water/ammonia solution, which has been on the market for a long time and recently innovated. Finally, a list of the main energy and cost advantages deriving from the use of absorption heat pumps is made [it

  3. Nuclear-pumped lasers

    CERN Document Server

    Prelas, Mark

    2016-01-01

    This book focuses on Nuclear-Pumped Laser (NPL) technology and provides the reader with a fundamental understanding of NPLs, a review of research in the field, and exploration of large scale NPL system design and applications. Early chapters look at the fundamental properties of lasers, nuclear-pumping and nuclear reactions that may be used as drivers for nuclear-pumped lasers. The book goes on to explore the efficient transport of energy from the ionizing radiation to the laser medium and then the operational characteristics of existing nuclear-pumped lasers. Models based on Mathematica, explanations and a tutorial all assist the reader’s understanding of this technology. Later chapters consider the integration of the various systems involved in NPLs and the ways in which they can be used, including beyond the military agenda. As readers will discover, there are significant humanitarian applications for high energy/power lasers, such as deflecting asteroids, space propulsion, power transmission and mining....

  4. Gas fired heat pumps

    International Nuclear Information System (INIS)

    Seifert, M.

    2006-01-01

    The condensing gas boiler is now state of the art and there is no more room for improvement in performance, technically speaking. The next logical step to improve the overall efficiency is to exploit ambient heat in combination with the primary source of energy, natural gas. That means using natural-gas driven heat pumps and gas-fired heat pumps. Based on this, the Swiss Gas Industry decided to set up a practical test programme enjoying a high priority. The aim of the project 'Gas-fired heat pump practical test' is to assess by field tests the characteristics and performance of the foreign serial heat pumps currently on the market and to prepare and promote the introduction on the market place of this sustainable natural-gas technology. (author)

  5. Absorption heat pump system

    Science.gov (United States)

    Grossman, G.

    1982-06-16

    The efficiency of an absorption heat pump system is improved by conducting liquid from a second stage evaporator thereof to an auxiliary heat exchanger positioned downstream of a primary heat exchanger in the desorber of the system.

  6. Regenerative Hydride Heat Pump

    Science.gov (United States)

    Jones, Jack A.

    1992-01-01

    Hydride heat pump features regenerative heating and single circulation loop. Counterflow heat exchangers accommodate different temperatures of FeTi and LaNi4.7Al0.3 subloops. Heating scheme increases efficiency.

  7. Pressurized Vessel Slurry Pumping

    International Nuclear Information System (INIS)

    Pound, C.R.

    2001-01-01

    This report summarizes testing of an alternate ''pressurized vessel slurry pumping'' apparatus. The principle is similar to rural domestic water systems and ''acid eggs'' used in chemical laboratories in that material is extruded by displacement with compressed air

  8. Mechanical vaccum pumps

    CERN Document Server

    Chew, A D

    2007-01-01

    This presentation gives an overview of the technology of contemporary primary and secondary mechanical vacuum pumps. For reference a brief history of vacuum and a summary of important and basic vacuum concepts are first presented.

  9. High Voltage Charge Pump

    KAUST Repository

    Emira, Ahmed A.; Abdelghany, Mohamed A.; Elsayed, Mohannad Yomn; Elshurafa, Amro M; Salama, Khaled N.

    2014-01-01

    Various embodiments of a high voltage charge pump are described. One embodiment is a charge pump circuit that comprises a plurality of switching stages each including a clock input, a clock input inverse, a clock output, and a clock output inverse. The circuit further comprises a plurality of pumping capacitors, wherein one or more pumping capacitors are coupled to a corresponding switching stage. The circuit also comprises a maximum selection circuit coupled to a last switching stage among the plurality of switching stages, the maximum selection circuit configured to filter noise on the output clock and the output clock inverse of the last switching stage, the maximum selection circuit further configured to generate a DC output voltage based on the output clock and the output clock inverse of the last switching stage.

  10. High Voltage Charge Pump

    KAUST Repository

    Emira, Ahmed A.

    2014-10-09

    Various embodiments of a high voltage charge pump are described. One embodiment is a charge pump circuit that comprises a plurality of switching stages each including a clock input, a clock input inverse, a clock output, and a clock output inverse. The circuit further comprises a plurality of pumping capacitors, wherein one or more pumping capacitors are coupled to a corresponding switching stage. The circuit also comprises a maximum selection circuit coupled to a last switching stage among the plurality of switching stages, the maximum selection circuit configured to filter noise on the output clock and the output clock inverse of the last switching stage, the maximum selection circuit further configured to generate a DC output voltage based on the output clock and the output clock inverse of the last switching stage.

  11. GAS METERING PUMP

    Science.gov (United States)

    George, C.M.

    1957-12-31

    A liquid piston gas pump is described, capable of pumping minute amounts of gas in accurately measurable quantities. The pump consists of a flanged cylindrical regulating chamber and a mercury filled bellows. Sealed to the ABSTRACTS regulating chamber is a value and having a gas inlet and outlet, the inlet being connected by a helical channel to the bellows. A gravity check valve is in the gas outlet, so the gas passes through the inlet and the helical channel to the bellows where the pumping action as well as the metering is accomplished by the actuation of the mercury filled bellows. The gas then flows through the check valve and outlet to any associated apparatus.

  12. JET pump limiter

    International Nuclear Information System (INIS)

    Sonnenberg, K.; Deksnis, E.; Shaw, R.; Reiter, D.

    1988-01-01

    JET plans to install two pump limiter modules which can be used for belt-limiter, inner-wall and X-point discharges and, also, for 1-2s as the main limiter. A design is presented which is compatible with two diagnostic systems, and which allows partial removal of the pump limiter to provide access for remote-handling operations. The high heat-flux components are initially cooled during a pulse. Heat is removed between discharges by radiation and pressure contacts to a water-cooled support structure. The pumping edge will be made of annealed pyrolytic graphite. Exhaust efficiency has been estimated, for a 1-d edge model, using a Monte-Carlo calculation of neutral gas transport. When the pump limiter is operated together with other wall components we expect an efficiency of ≅ 5% (2.5 x 10 21 part/s). As a main limiter the efficiency increases to about 10%. (author)

  13. Types of Breast Pumps

    Science.gov (United States)

    ... called a bicycle horn pump, consists of a hollow rubber ball attached to a breast-shield. Some ... and Drug Administration 10903 New Hampshire Avenue Silver Spring, MD 20993 1-888-INFO-FDA (1-888- ...

  14. Propofol Infusion Syndrome Heralded by ECG Changes

    NARCIS (Netherlands)

    Mijzen, Elsbeth J.; Jacobs, Bram; Aslan, Adnan; Rodgers, Michael G. G.

    2012-01-01

    Propofol infusion syndrome (PRIS) is well known, often associated with, lethal complication of sedation with propofol. PRIS seems to be associated with young age, traumatic brain injury (TBI), higher cumulative doses of propofol, and the concomitant use of catecholamines. Known manifestations of

  15. Infusing Functional Law into the Classroom.

    Science.gov (United States)

    Frieman, Barry B.; Fine, Bobbie

    The court system touches the lives of many children in the school system, some through divorce, and others through their own illegal behavior. Principals and administrators need to infuse a functional knowledge of the legal system so that these children will be better able to cope and deal with life events that cause them to be placed in contact…

  16. Reaction between infusion water and methane

    Energy Technology Data Exchange (ETDEWEB)

    Ettinger, I L

    1977-09-01

    This paper discusses the effect of infused water on the initial gas emission rate and on the pore structure of the coal. Water traps methane in micro-pores, so that lengthy periods are needed for the methane to penetrate large voids and cavities.

  17. Routine saline infusion sonohysterography prior to assisted ...

    African Journals Online (AJOL)

    53.85%), 8 (30.77%) and 4 (15.38%) respectively. The average duration of the procedure was 6 minutes with a range of 4-9 minutes. Saline infusion sonohysterography is a reliable, cost effective and safe diagnostic tool in the evaluation of the ...

  18. Region-of-interest volumetric visual hull refinement

    KAUST Repository

    Knoblauch, Daniel; Kuester, Falko

    2010-01-01

    This paper introduces a region-of-interest visual hull refinement technique, based on flexible voxel grids for volumetric visual hull reconstructions. Region-of-interest refinement is based on a multipass process, beginning with a focussed visual

  19. Non-uniform volumetric structures in Richtmyer-Meshkov flows

    NARCIS (Netherlands)

    Staniç, M.; McFarland, J.; Stellingwerf, R.F.; Cassibry, J.T.; Ranjan, D.; Bonazza, R.; Greenough, J.A.; Abarzhi, S.I.

    2013-01-01

    We perform an integrated study of volumetric structures in Richtmyer-Meshkov (RM) flows induced by moderate shocks. Experiments, theoretical analyses, Smoothed Particle Hydrodynamics simulations, and ARES Arbitrary Lagrange Eulerian simulations are employed to analyze RM evolution for fluids with

  20. Characterizing volumetric deformation behavior of naturally occuring bituminous sand materials

    CSIR Research Space (South Africa)

    Anochie-Boateng, Joseph

    2009-05-01

    Full Text Available newly proposed hydrostatic compression test procedure. The test procedure applies field loading conditions of off-road construction and mining equipment to closely simulate the volumetric deformation and stiffness behaviour of oil sand materials. Based...

  1. Optically pumped laser systems

    International Nuclear Information System (INIS)

    DeMaria, A.J.; Mack, M.E.

    1975-01-01

    Laser systems which are pumped by an electric discharge formed in a gas are disclosed. The discharge is in the form of a vortex stabilized electric arc which is triggered with an auxiliary energy source. At high enough repetition rates residual ionization between successive pulses contributes to the pulse stabilization. The arc and the gain medium are positioned inside an optical pumping cavity where light from the arc is coupled directly into the gain medium

  2. Lunar Base Heat Pump

    Science.gov (United States)

    Walker, D.; Fischbach, D.; Tetreault, R.

    1996-01-01

    The objective of this project was to investigate the feasibility of constructing a heat pump suitable for use as a heat rejection device in applications such as a lunar base. In this situation, direct heat rejection through the use of radiators is not possible at a temperature suitable for lde support systems. Initial analysis of a heat pump of this type called for a temperature lift of approximately 378 deg. K, which is considerably higher than is commonly called for in HVAC and refrigeration applications where heat pumps are most often employed. Also because of the variation of the rejection temperature (from 100 to 381 deg. K), extreme flexibility in the configuration and operation of the heat pump is required. A three-stage compression cycle using a refrigerant such as CFC-11 or HCFC-123 was formulated with operation possible with one, two or three stages of compression. Also, to meet the redundancy requirements, compression was divided up over multiple compressors in each stage. A control scheme was devised that allowed these multiple compressors to be operated as required so that the heat pump could perform with variable heat loads and rejection conditions. A prototype heat pump was designed and constructed to investigate the key elements of the high-lift heat pump concept. Control software was written and implemented in the prototype to allow fully automatic operation. The heat pump was capable of operation over a wide range of rejection temperatures and cooling loads, while maintaining cooling water temperature well within the required specification of 40 deg. C +/- 1.7 deg. C. This performance was verified through testing.

  3. Resorption heat pump

    International Nuclear Information System (INIS)

    Vasiliev, L.L.; Mishkinis, D.A.; Antukh, A.A.; Kulakov, A.G.; Vasiliev, L.L.

    2004-01-01

    Resorption processes are based on at least two solid-sorption reactors application. The most favorable situation for the resorption heat pumps is the case, when the presence of a liquid phase is impossible. From simple case--two reactors with two salts to complicated system with two salts + active carbon fiber (fabric) and two branch of the heat pump acting out of phase to produce heat and cold simultaneously, this is the topic of this research program

  4. Portable photovoltaic irrigation pumps

    Energy Technology Data Exchange (ETDEWEB)

    Furber, J. D.

    1980-07-01

    Experiences in developing a solar-powered irrigation pump to meet the needs of poor farmers in developing nations are summarized. The design which evolved is small and portable, employing a high-efficiency electric pump, powered by photovoltaic panels. Particular emphasis is placed on how the system works, and on early field problems experienced with the first prototypes. The resolution of these problems and the performance of actual systems in various countries is presented and user responses are noted.

  5. Tokamak pump limiters

    International Nuclear Information System (INIS)

    Conn, R.W.

    1984-05-01

    Recent experiments with a scoop limiter without active internal pumping have been carried out in the PDX tokamak with up to 6MW of auxiliary neutral beam heating. Experiments have also been done with a rotating head pump limiter in the PLT tokamak in conjunction with RF plasma heating. Extensive experiments have been done in the ISX-B tokamak and first experiments have been completed with the ALT-I limiter in TEXTOR. The pump limiter modules in these latter two machines have internal getter pumping. Experiments in ISX-B are with ohmic and auxiliary neutral beam heating. The results in ISX-B and TEXTOR show that active density control and particle removal is achieved with pump limiters. In ISX-B, the boundary layer (or scape-off layer) plasma partially screens the core plasma from gas injection. In both ISX-B and TEXTOR, the pressure internal to the module scales linearly with plasma density but in ISX-B, with neutral beam injection, a nonlinear increase is observed at the highest densities studied. Plasma plugging is the suspected cause. Results from PDX suggest that a region may exist in which core plasma energy confinement improves using a pump limiter during neutral beam injection. Asymmetric radial profiles and an increased edge electron temperature are observed in discharges with improved confinement. The injection of small amounts of neon into ISX-B has more clearly shown an improved electron core energy confinement during neutral beam injection. While carried out with a regular limiter, this Z-mode of operation is ideal for use with pump limiters and should be a way to achieve energy confinement times similar to values for H-mode tokamak plasmas. The implication of all these results for the design of a reactor pump limiter is described

  6. Tokamak pump limiters

    International Nuclear Information System (INIS)

    Conn, R.W.; California Univ., Los Angeles

    1984-01-01

    Recent experiments with a scoop limiter without active internal pumping have been carried out in the PDX tokamak with up to 6 MW of auxiliary neutral beam heating. Experiments have also been performed with a rotating head pump limiter in the PLT tokamak in conjunction with RF plasma heating. Extensive experiments have been done in the ISX-B tokamak and first experiments have been completed with the ALT-I limiter in TEXTOR. The pump limiter modules in these latter two machines have internal getter pumping. Experiments in ISX-B are with ohmic and auxiliary neutral beam heating. The results in ISX-B and TEXTOR show that active density control and particle removal is achieved with pump limiters. In ISX-B, the boundary layer (or scrape-off layer) plasma partially screens the core plasma from gas injection. In both ISX-B and TEXTOR, the pressure internal to the module scales linearly with plasma density but in ISX-B, with neutral beam injection, a nonlinear increase is observed at the highest densities studied. Plasma plugging is the suspected cause. Results from PDX suggest that a regime may exist in which core plasma energy confinement improves using a pump limiter during neutral beam injection. Asymmetric radial profiles and an increased edge electron temperature are observed in discharges with improved confinement. The injection of small amounts of neon into ISX-B has more clearly shown an improved electron core energy confinement during neutral beam injection. While carried out with a regular limiter, this 'Z-mode' of operation is ideal for use with pump limiters and should be a way to achieve energy confinement times similar to values for H-mode tokamak plasmas. The implication of all these results for the design of a reactor pump limiter is described. (orig.)

  7. Energy efficiency in pumps

    Energy Technology Data Exchange (ETDEWEB)

    Kaya, Durmus; Yagmur, E. Alptekin [TUBITAK-MRC, P.O. Box 21, 41470 Gebze, Kocaeli (Turkey); Yigit, K. Suleyman; Eren, A. Salih; Celik, Cenk [Engineering Faculty, Kocaeli University, Kocaeli (Turkey); Kilic, Fatma Canka [Department of Air Conditioning and Refrigeration, Kocaeli University, Kullar, Kocaeli (Turkey)

    2008-06-15

    In this paper, ''energy efficiency'' studies, done in a big industrial facility's pumps, are reported. For this purpose; the flow rate, pressure and temperature have been measured for each pump in different operating conditions and at maximum load. In addition, the electrical power drawn by the electric motor has been measured. The efficiencies of the existing pumps and electric motor have been calculated by using the measured data. Potential energy saving opportunities have been studied by taking into account the results of the calculations for each pump and electric motor. As a conclusion, improvements should be made each system. The required investment costs for these improvements have been determined, and simple payback periods have been calculated. The main energy saving opportunities result from: replacements of the existing low efficiency pumps, maintenance of the pumps whose efficiencies start to decline at certain range, replacements of high power electric motors with electric motors that have suitable power, usage of high efficiency electric motors and elimination of cavitation problems. (author)

  8. Energy efficiency in pumps

    International Nuclear Information System (INIS)

    Kaya, Durmus; Yagmur, E. Alptekin; Yigit, K. Suleyman; Kilic, Fatma Canka; Eren, A. Salih; Celik, Cenk

    2008-01-01

    In this paper, 'energy efficiency' studies, done in a big industrial facility's pumps, are reported. For this purpose; the flow rate, pressure and temperature have been measured for each pump in different operating conditions and at maximum load. In addition, the electrical power drawn by the electric motor has been measured. The efficiencies of the existing pumps and electric motor have been calculated by using the measured data. Potential energy saving opportunities have been studied by taking into account the results of the calculations for each pump and electric motor. As a conclusion, improvements should be made each system. The required investment costs for these improvements have been determined, and simple payback periods have been calculated. The main energy saving opportunities result from: replacements of the existing low efficiency pumps, maintenance of the pumps whose efficiencies start to decline at certain range, replacements of high power electric motors with electric motors that have suitable power, usage of high efficiency electric motors and elimination of cavitation problems

  9. Real-time volumetric scintillation dosimetry

    International Nuclear Information System (INIS)

    Beddar, S

    2015-01-01

    The goal of this brief review is to review the current status of real-time 3D scintillation dosimetry and what has been done so far in this area. The basic concept is to use a large volume of a scintillator material (liquid or solid) to measure or image the dose distributions from external radiation therapy (RT) beams in three dimensions. In this configuration, the scintillator material fulfills the dual role of being the detector and the phantom material in which the measurements are being performed. In this case, dose perturbations caused by the introduction of a detector within a phantom will not be at issue. All the detector configurations that have been conceived to date used a Charge-Coupled Device (CCD) camera to measure the light produced within the scintillator. In order to accurately measure the scintillation light, one must correct for various optical artefacts that arise as the light propagates from the scintillating centers through the optical chain to the CCD chip. Quenching, defined in its simplest form as a nonlinear response to high-linear energy transfer (LET) charged particles, is one of the disadvantages when such systems are used to measure the absorbed dose from high-LET particles such protons. However, correction methods that restore the linear dose response through the whole proton range have been proven to be effective for both liquid and plastic scintillators. Volumetric scintillation dosimetry has the potential to provide fast, high-resolution and accurate 3D imaging of RT dose distributions. Further research is warranted to optimize the necessary image reconstruction methods and optical corrections needed to achieve its full potential

  10. Volumetric optoacoustic monitoring of endovenous laser treatments

    Science.gov (United States)

    Fehm, Thomas F.; Deán-Ben, Xosé L.; Schaur, Peter; Sroka, Ronald; Razansky, Daniel

    2016-03-01

    Chronic venous insufficiency (CVI) is one of the most common medical conditions with reported prevalence estimates as high as 30% in the adult population. Although conservative management with compression therapy may improve the symptoms associated with CVI, healing often demands invasive procedures. Besides established surgical methods like vein stripping or bypassing, endovenous laser therapy (ELT) emerged as a promising novel treatment option during the last 15 years offering multiple advantages such as less pain and faster recovery. Much of the treatment success hereby depends on monitoring of the treatment progression using clinical imaging modalities such as Doppler ultrasound. The latter however do not provide sufficient contrast, spatial resolution and three-dimensional imaging capacity which is necessary for accurate online lesion assessment during treatment. As a consequence, incidence of recanalization, lack of vessel occlusion and collateral damage remains highly variable among patients. In this study, we examined the capacity of volumetric optoacoustic tomography (VOT) for real-time monitoring of ELT using an ex-vivo ox foot model. ELT was performed on subcutaneous veins while optoacoustic signals were acquired and reconstructed in real-time and at a spatial resolution in the order of 200μm. VOT images showed spatio-temporal maps of the lesion progression, characteristics of the vessel wall, and position of the ablation fiber's tip during the pull back. It was also possible to correlate the images with the temperature elevation measured in the area adjacent to the ablation spot. We conclude that VOT is a promising tool for providing online feedback during endovenous laser therapy.

  11. Serial volumetric registration of pulmonary CT studies

    Science.gov (United States)

    Silva, José Silvestre; Silva, Augusto; Sousa Santos, Beatriz

    2008-03-01

    Detailed morphological analysis of pulmonary structures and tissue, provided by modern CT scanners, is of utmost importance as in the case of oncological applications both for diagnosis, treatment, and follow-up. In this case, a patient may go through several tomographic studies throughout a period of time originating volumetric sets of image data that must be appropriately registered in order to track suspicious radiological findings. The structures or regions of interest may change their position or shape in CT exams acquired at different moments, due to postural, physiologic or pathologic changes, so, the exams should be registered before any follow-up information can be extracted. Postural mismatching throughout time is practically impossible to avoid being particularly evident when imaging is performed at the limiting spatial resolution. In this paper, we propose a method for intra-patient registration of pulmonary CT studies, to assist in the management of the oncological pathology. Our method takes advantage of prior segmentation work. In the first step, the pulmonary segmentation is performed where trachea and main bronchi are identified. Then, the registration method proceeds with a longitudinal alignment based on morphological features of the lungs, such as the position of the carina, the pulmonary areas, the centers of mass and the pulmonary trans-axial principal axis. The final step corresponds to the trans-axial registration of the corresponding pulmonary masked regions. This is accomplished by a pairwise sectional registration process driven by an iterative search of the affine transformation parameters leading to optimal similarity metrics. Results with several cases of intra-patient, intra-modality registration, up to 7 time points, show that this method provides accurate registration which is needed for quantitative tracking of lesions and the development of image fusion strategies that may effectively assist the follow-up process.

  12. Dual-gated volumetric modulated arc therapy

    International Nuclear Information System (INIS)

    Fahimian, Benjamin; Wu, Junqing; Wu, Huanmei; Geneser, Sarah; Xing, Lei

    2014-01-01

    Gated Volumetric Modulated Arc Therapy (VMAT) is an emerging radiation therapy modality for treatment of tumors affected by respiratory motion. However, gating significantly prolongs the treatment time, as delivery is only activated during a single respiratory phase. To enhance the efficiency of gated VMAT delivery, a novel dual-gated VMAT (DG-VMAT) technique, in which delivery is executed at both exhale and inhale phases in a given arc rotation, is developed and experimentally evaluated. Arc delivery at two phases is realized by sequentially interleaving control points consisting of MUs, MLC sequences, and angles of VMAT plans generated at the exhale and inhale phases. Dual-gated delivery is initiated when a respiration gating signal enters the exhale window; when the exhale delivery concludes, the beam turns off and the gantry rolls back to the starting position for the inhale window. The process is then repeated until both inhale and exhale arcs are fully delivered. DG-VMAT plan delivery accuracy was assessed using a pinpoint chamber and diode array phantom undergoing programmed motion. DG-VMAT delivery was experimentally implemented through custom XML scripting in Varian’s TrueBeam™ STx Developer Mode. Relative to single gated delivery at exhale, the treatment time was improved by 95.5% for a sinusoidal breathing pattern. The pinpoint chamber dose measurement agreed with the calculated dose within 0.7%. For the DG-VMAT delivery, 97.5% of the diode array measurements passed the 3%/3 mm gamma criterion. The feasibility of DG-VMAT delivery scheme has been experimentally demonstrated for the first time. By leveraging the stability and natural pauses that occur at end-inspiration and end-exhalation, DG-VMAT provides a practical method for enhancing gated delivery efficiency by up to a factor of two

  13. Volumetric breast density affects performance of digital screening mammography

    OpenAIRE

    Wanders, JO; Holland, K; Veldhuis, WB; Mann, RM; Pijnappel, RM; Peeters, PH; Van Gils, CH; Karssemeijer, N

    2016-01-01

    PURPOSE: To determine to what extent automatically measured volumetric mammographic density influences screening performance when using digital mammography (DM). METHODS: We collected a consecutive series of 111,898 DM examinations (2003-2011) from one screening unit of the Dutch biennial screening program (age 50-75 years). Volumetric mammographic density was automatically assessed using Volpara. We determined screening performance measures for four density categories comparable to the Ameri...

  14. BIOMATERIALS FOR ROTARY BLOOD PUMPS

    NARCIS (Netherlands)

    VANOEVEREN, W

    Rotary blood pumps are used for cardiac assist and cardiopulmonary support since mechanical blood damage is less than with conventional roller pumps. The high shear rate in the rotary pump and the reduced anticoagulation of the patient during prolonged pumping enforces high demands on the

  15. Bronchial arterial infusion versus bronchial combined pulmonary arterial infusion for pulmonary metastatic tumors

    International Nuclear Information System (INIS)

    Dong Sheng; Dong Weihua; Jia Ningyang; Zhang Dianbo; Xiao Xiangsheng

    2008-01-01

    Objective: To evaluate the pulmonary metastatic tumor response to different ways of transcatheter arterial infusion. Methods: Thirty-five patients with pulmonary metastatic tumors were randomized divided into two groups: 15 patients with 49 lesions treated with bronchial arterial infusion (BAI) and 20 patients with 65 lesions treated with bronchial arterial infusion (BM)combined with pulmonary arterial infusion (PAI). The therapeutic response was assessed by the WHO evaluation criteria. Results: The total effective rate(CR + PR) of BAI was 65.3% (32/49), PAI + BAI was 61.5%(40/65) showing no statistical difference. The median survival time of BAI was 9 mo, BAI + PAI was 11.5 mo, demonstrating no statistical significance. Conclusions: BAI should be the primary treatment for pulmonary metastatic tumor. (authors)

  16. Propofol drip infusion anesthesia for MRI scanning: two case reports.

    Science.gov (United States)

    Sasao-Takano, Mami; Misumi, Kan; Suzuki, Masayuki; Kamiya, Yoko; Noguchi, Izumi; Kawahara, Hiroshi

    2013-01-01

    The magnetic resonance imaging (MRI) room is a special environment. The required intense magnetic fields create unique problems with the use of standard anesthesia machines, syringe pumps, and physiologic monitors. We have recently experienced 2 oral maxillofacial surgery cases requiring MRI: a 15-year-old boy with developmental disability and a healthy 5-year-old boy. The patients required complete immobilization during the scanning for obtaining high-quality images for the best diagnosis. Anesthesia was started in the MRI scanning room. An endotracheal intubation was performed after induction with intravenous administration of muscle relaxant. Total intravenous anesthesia via propofol drip infusion (4-7 mg/kg/h) was used during the scanning. Standard physiologic monitors were used during scan pauses, but special monitors were used during scanning. In MRI scanning for oral maxillofacial surgery, general anesthesia, with the added advantage of having a secured airway, is recommended as a safe alternative to sedation especially in cases of patients with disability and precooperative chidren.

  17. Impact of electricity prices and volumetric water allocation on energy and groundwater demand management: analysis from Western India

    International Nuclear Information System (INIS)

    Kumar, M.D.

    2005-01-01

    In recent years, power tariff policy has been increasingly advocated as a mean to influence groundwater use and withdrawal decisions of farmers in view of the failure of existing direct and indirect regulations on groundwater withdrawal in India. Many researchers argue that pro rata electricity tariff, with built in positive marginal cost of pumping could bring about efficient use of the resource, though some argue that the levels of tariff in which demand becomes elastic to pricing are too high to be viable from political and socio-economic points of view. The paper presents a theoretical model to analyze farmers' response to changes in power tariff and water allocation regimes vis a vis energy and groundwater use. It validates the model by analyzing water productivity in groundwater irrigation under different electricity pricing structures and water allocation regimes. Water productivity was estimated using primary data of gross crop inputs, cost of all inputs, and volumetric water inputs. The analysis shows that unit pricing of electricity influences groundwater use efficiency and productivity positively. It also shows that the levels of pricing at which demand for electricity and groundwater becomes elastic to tariff are socio-economically viable. Further, water productivity impacts of pricing would be highest when water is volumetrically allocated with rationing. Therefore, an effective power tariff policy followed by enforcement of volumetric water allocation could address the issue of efficiency, sustainability and equity in groundwater use in India

  18. Angiotensin II-induced hypertension increases plasma membrane Na pump activity by enhancing Na entry in rat thick ascending limbs.

    Science.gov (United States)

    Gonzalez-Vicente, Agustin; Garvin, Jeffrey L

    2013-11-01

    Thick ascending limbs (TAL) reabsorb 30% of the filtered NaCl load. Na enters the cells via apical Na-K-2Cl cotransporters and Na/H exchangers and exits via basolateral Na pumps. Chronic angiotensin II (ANG II) infusion increases net TAL Na transport and Na apical entry; however, little is known about its effects on the basolateral Na pump. We hypothesized that in rat TALs Na pump activity is enhanced by ANG II-infusion, a model of ANG II-induced hypertension. Rats were infused with 200 ng·kg(-1)·min(-1) ANG II or vehicle for 7 days, and TAL suspensions were obtained. We studied plasma membrane Na pump activity by measuring changes in 1) intracellular Na (Nai) induced by ouabain; and 2) ouabain-sensitive oxygen consumption (QO2). We found that the ouabain-sensitive rise in Nai in TALs from ANG II-infused rats was 12.8 ± 0.4 arbitrary fluorescent units (AFU)·mg(-1)·min(-1) compared with only 9.9 ± 1.1 AFU·mg(-1)·min(-1) in controls (P Na pump expression, the number of Na pumps in the plasma membrane, or the affinity for Na. When furosemide (1.1 mg·kg(-1)·day(-1)) was coinfused with ANG II, no increase in plasma membrane Na pump activity was observed. We concluded that in ANG II-induced hypertension Na pump activity is increased in the plasma membrane of TALs and that this increase is caused by the chronically enhanced Na entry occurring in this model.

  19. Soft bilateral filtering volumetric shadows using cube shadow maps.

    Directory of Open Access Journals (Sweden)

    Hatam H Ali

    Full Text Available Volumetric shadows often increase the realism of rendered scenes in computer graphics. Typical volumetric shadows techniques do not provide a smooth transition effect in real-time with conservation on crispness of boundaries. This research presents a new technique for generating high quality volumetric shadows by sampling and interpolation. Contrary to conventional ray marching method, which requires extensive time, this proposed technique adopts downsampling in calculating ray marching. Furthermore, light scattering is computed in High Dynamic Range buffer to generate tone mapping. The bilateral interpolation is used along a view rays to smooth transition of volumetric shadows with respect to preserving-edges. In addition, this technique applied a cube shadow map to create multiple shadows. The contribution of this technique isreducing the number of sample points in evaluating light scattering and then introducing bilateral interpolation to improve volumetric shadows. This contribution is done by removing the inherent deficiencies significantly in shadow maps. This technique allows obtaining soft marvelous volumetric shadows, having a good performance and high quality, which show its potential for interactive applications.

  20. Visualization and volumetric structures from MR images of the brain

    Energy Technology Data Exchange (ETDEWEB)

    Parvin, B.; Johnston, W.; Robertson, D.

    1994-03-01

    Pinta is a system for segmentation and visualization of anatomical structures obtained from serial sections reconstructed from magnetic resonance imaging. The system approaches the segmentation problem by assigning each volumetric region to an anatomical structure. This is accomplished by satisfying constraints at the pixel level, slice level, and volumetric level. Each slice is represented by an attributed graph, where nodes correspond to regions and links correspond to the relations between regions. These regions are obtained by grouping pixels based on similarity and proximity. The slice level attributed graphs are then coerced to form a volumetric attributed graph, where volumetric consistency can be verified. The main novelty of our approach is in the use of the volumetric graph to ensure consistency from symbolic representations obtained from individual slices. In this fashion, the system allows errors to be made at the slice level, yet removes them when the volumetric consistency cannot be verified. Once the segmentation is complete, the 3D surfaces of the brain can be constructed and visualized.

  1. Pumps in nuclear power plants

    International Nuclear Information System (INIS)

    Kim, J.H.

    1991-01-01

    This paper reports that pumps play an important role in nuclear plant operation. For instance, reactor coolant pumps (RCPs) should provide adequate cooling for reactor core in both normal operation and transient or accident conditions. Pumps such as Low Pressure Safety Injection (LPSI) pump in the Emergency Core Cooling System (ECCS) play a crucial role during an accident, and their reliability is of paramount importance. Some key issues involved with pumps in nuclear plant system include the performance of RCP under two-phase flow conditions, piping vibration due to pump operating in two-phase flows, and reliability of LPSI pumps

  2. Inservice testing of vertical pumps

    International Nuclear Information System (INIS)

    Cornman, R.E. Jr.; Schumann, K.E.

    1994-01-01

    This paper focuses on the problems that may occur with vertical pumps while inservice tests are conducted in accordance with existing American Society of Mechanical Engineers Code, Section XI, standards. The vertical pump types discussed include single stage, multistage, free surface, and canned mixed flow pumps. Primary emphasis is placed on the hydraulic performance of the pump and the internal and external factors to the pump that impact hydraulic performance. In addition, the paper considers the mechanical design features that can affect the mechanical performance of vertical pumps. The conclusion shows how two recommended changes in the Code standards may increase the quality of the pump's operational readiness assessment during its service life

  3. Thermally Actuated Hydraulic Pumps

    Science.gov (United States)

    Jones, Jack; Ross, Ronald; Chao, Yi

    2008-01-01

    Thermally actuated hydraulic pumps have been proposed for diverse applications in which direct electrical or mechanical actuation is undesirable and the relative slowness of thermal actuation can be tolerated. The proposed pumps would not contain any sliding (wearing) parts in their compressors and, hence, could have long operational lifetimes. The basic principle of a pump according to the proposal is to utilize the thermal expansion and contraction of a wax or other phase-change material in contact with a hydraulic fluid in a rigid chamber. Heating the chamber and its contents from below to above the melting temperature of the phase-change material would cause the material to expand significantly, thus causing a substantial increase in hydraulic pressure and/or a substantial displacement of hydraulic fluid out of the chamber. Similarly, cooling the chamber and its contents from above to below the melting temperature of the phase-change material would cause the material to contract significantly, thus causing a substantial decrease in hydraulic pressure and/or a substantial displacement of hydraulic fluid into the chamber. The displacement of the hydraulic fluid could be used to drive a piston. The figure illustrates a simple example of a hydraulic jack driven by a thermally actuated hydraulic pump. The pump chamber would be a cylinder containing encapsulated wax pellets and containing radial fins to facilitate transfer of heat to and from the wax. The plastic encapsulation would serve as an oil/wax barrier and the remaining interior space could be filled with hydraulic oil. A filter would retain the encapsulated wax particles in the pump chamber while allowing the hydraulic oil to flow into and out of the chamber. In one important class of potential applications, thermally actuated hydraulic pumps, exploiting vertical ocean temperature gradients for heating and cooling as needed, would be used to vary hydraulic pressures to control buoyancy in undersea research

  4. Subcutaneous infusion in palliative care: a focus on the neria soft 90 infusion set.

    Science.gov (United States)

    Gabriel, Janice

    2014-11-01

    Subcutaneous administration of medications and/or fluids can play a crucial part in supporting patients at home and thereby avoiding the need for hospitalisation. It is an area of patient care that has received little attention compared with other types of parenteral therapies. However, it is an effective and safe route for continuous administration for individuals requiring palliative care. Technological advancements have led to improved subcutaneous infusion devices, such as fine-gauge cannulae with integral sharps protection, as well as integral hypoallergenic dressings. These design features not only help to increase patient comfort but also minimise the potential for needlestick injuries, as well as providing the health professional with one sterile package containing all of the components needed to establish subcutaneous infusion. However, technological developments alone are insufficient to improve patient outcomes. Knowledge of the individual patient, together with their diagnosis and intended treatment, will influence the choice of subcutaneous infusion device, with the overall aim of minimising the potential for complications and improving comfort. This paper provides an overview of subcutaneous infusion, including the importance of patient assessment and the education and training needs of health professionals, and then focuses on one specific subcutaneous infusion device: the neria soft 90 infusion set.

  5. Respiratory failure following delayed intrathecal morphine pump refill: a valuable, but costly lesson.

    Science.gov (United States)

    Ruan, Xiulu; Couch, J Patrick; Liu, HaiNan; Shah, Rinoo V; Wang, Frank; Chiravuri, Srinivas

    2010-01-01

    Spinal analgesia, mediated by opioid receptors, requires only a fraction of the opioid dose that is needed systemically. By infusing a small amount of opioid into the cerebrospinal fluid in close proximity to the receptor sites in the spinal cord, profound analgesia may be achieved while sparing some of the side effects due to systemic opioids. Intraspinal drug delivery (IDD) has been increasingly used in patients with intractable chronic pain, when these patients have developed untoward side effects with systemic opioid usage. The introduction of intrathecal opioids has been considered one of the most important breakthroughs in pain management in the past three decades. A variety of side effects associated with the long-term usage of IDD have been recognized. Among them, respiratory depression is the most feared. To describe a severe adverse event, i.e., respiratory failure, following delayed intrathecal morphine pump refill. A 65-year-old woman with intractable chronic low back pain, due to degenerative disc disease, and was referred to our clinic for an intraspinal drug delivery evaluation, after failing to respond to multidisciplinary pain treatment. Following a psychological evaluation confirming her candidacy, she underwent an outpatient patient-controlled continuous epidural morphine infusion trial. The infusion trial lasted 12 days and was beneficial in controlling her pain. The patient reported more than 90% pain reduction with improved distance for ambulation. She subsequently consented and was scheduled for permanent intrathecal morphine pump implantation. The intrathecal catheter was inserted at right paramedian L3-L4, with catheter tip advanced to L1, confirmed under fluoroscopy. Intrathecal catheter placement was confirmed by positive CSF flow and by myelogram. A non-programmable Codman 3000 constant-flow rate infusion pump was placed in the right mid quandrant between right rib cage and right iliac crest. The intrathecal infusion consisted of

  6. Slip flow coefficient analysis in water hydraulics gear pump for environmental friendly application

    International Nuclear Information System (INIS)

    Yusof, A A; Wasbari, F; Zakaria, M S; Ibrahim, M Q

    2013-01-01

    Water hydraulics is the sustainable option in developing fluid power systems with environmental friendly approach. Therefore, an investigation on water-based external gear pump application is being conducted, as a low cost solution in the shifting effort of using water, instead of traditional oil hydraulics in fluid power application. As the gear pump is affected by fluid viscosity, an evaluation has been conducted on the slip flow coefficient, in order to understand to what extent the spur gear pump can be used with water-based hydraulic fluid. In this paper, the results of a simulated study of variable-speed fixed displacement gear pump are presented. The slip flow coefficient varies from rotational speed of 250 RPM to 3500 RPM, and provides volumetric efficiency ranges from 9 % to 97% accordingly

  7. An audit of hospital based outpatient infusions and a pilot program of community-based monoclonal antibody infusions.

    LENUS (Irish Health Repository)

    Doran, J-P

    2012-02-01

    INTRODUCTION: Infliximab, a chimeric monoclonal antibody to tumour necrosis factor alpha, is administered as an intravenous infusion requiring a costly hospital day case or inpatient admission. METHODS: An audit of all current therapies given by intravenous infusions in an outpatient setting in St Vincent\\'s University Hospital (SVUH) was undertaken. Furthermore, in conjunction with TCP homecare, we established in a general practise health clinic, the first Irish community infusion centre for the administration of infliximab in August 2006. RESULTS: All outpatient departments indicated that they would favour a centralized hospital infusion unit. There were no adverse events and the mean global satisfaction improved in the community infliximab infusion pilot programme of seven patients. CONCLUSION: This study suggests efficiencies in providing centralized infusion facilities, while the community based infusion of infliximab is feasible and safe in this small cohort and identifies the community infusion unit as a viable and cost efficient alternative for administration of infliximab.

  8. Volumetric modulated arc radiotherapy for esophageal cancer

    International Nuclear Information System (INIS)

    Vivekanandan, Nagarajan; Sriram, Padmanaban; Syam Kumar, S.A.; Bhuvaneswari, Narayanan; Saranya, Kamalakannan

    2012-01-01

    A treatment planning study was performed to evaluate the performance of volumetric arc modulation with RapidArc (RA) against 3D conformal radiation therapy (3D-CRT) and conventional intensity-modulated radiation therapy (IMRT) techniques for esophageal cancer. Computed tomgraphy scans of 10 patients were included in the study. 3D-CRT, 4-field IMRT, and single-arc and double-arc RA plans were generated with the aim to spare organs at risk (OAR) and healthy tissue while enforcing highly conformal target coverage. The planning objective was to deliver 54 Gy to the planning target volume (PTV) in 30 fractions. Plans were evaluated based on target conformity and dose-volume histograms of organs at risk (lung, spinal cord, and heart). The monitor unit (MU) and treatment delivery time were also evaluated to measure the treatment efficiency. The IMRT plan improves target conformity and spares OAR when compared with 3D-CRT. Target conformity improved with RA plans compared with IMRT. The mean lung dose was similar in all techniques. However, RA plans showed a reduction in the volume of the lung irradiated at V 20Gy and V 30Gy dose levels (range, 4.62–17.98%) compared with IMRT plans. The mean dose and D 35% of heart for the RA plans were better than the IMRT by 0.5–5.8%. Mean V 10Gy and integral dose to healthy tissue were almost similar in all techniques. But RA plans resulted in a reduced low-level dose bath (15–20 Gy) in the range of 14–16% compared with IMRT plans. The average MU needed to deliver the prescribed dose by RA technique was reduced by 20–25% compared with IMRT technique. The preliminary study on RA for esophageal cancers showed improvements in sparing OAR and healthy tissue with reduced beam-on time, whereas only double-arc RA offered improved target coverage compared with IMRT and 3D-CRT plans.

  9. A reciprocating liquid helium pump used for forced flow of supercritical helium

    International Nuclear Information System (INIS)

    Krafft, G.; Zahn, G.

    1978-01-01

    The performance of a small double acting piston pump for circulating helium in a closed heat transfer loop is described. The pump was manufactured by LINDE AG, Munich, West Germany. The measured flow rate of supercritical helium was about 17 gs -1 (500 lhr -1 ) with a differential pressure of Δp = 0.5 x 10 5 Nm -2 at a working pressure of p = 6 x 10 5 Nm -2 . At differential pressures beyond 0.5 x 10 5 Nm -2 the volumetric efficiency decreases. (author)

  10. Type of homogenization and fat loss during continuous infusion of human milk.

    Science.gov (United States)

    García-Lara, Nadia Raquel; Escuder-Vieco, Diana; Alonso Díaz, Clara; Vázquez Román, Sara; De la Cruz-Bértolo, Javier; Pallás-Alonso, Carmen Rosa

    2014-11-01

    Substantial fat loss may occur during continuous feeding of human milk (HM). A decrease of fat loss has been described following homogenization. Well-established methods of homogenization of HM for routine use in the neonatal intensive care unit (NICU) would be desirable. We compared the loss of fat based on the use of 3 different methods for homogenizing thawed HM during continuous feeding. Sixteen frozen donor HM samples were thawed, homogenized with ultrasound and separated into 3 aliquots ("baseline agitation," "hourly agitation," and "ultrasound"), and then frozen for 48 hours. Aliquots were thawed again and a baseline agitation was applied. Subsequently, aliquots baseline agitation and hourly agitation were drawn into a syringe, while ultrasound was applied to aliquot ultrasound before it was drawn into a syringe. The syringes were loaded into a pump (2 mL/h; 4 hours). At hourly intervals the hourly agitation infusion was stopped, the syringe was disconnected and gently shaken. During infusion, samples from the 3 groups were collected hourly for analysis of fat and caloric content. The 3 groups of homogenization showed similar fat content at the beginning of the infusion. For fat, mean (SD) hourly changes of -0.03 (0.01), -0.09 (0.01), and -0.09 (0.01) g/dL were observed for the hourly agitation, baseline agitation, and ultrasound groups, respectively. The decrease was smaller for the hourly agitation group (P homogenization is used. © The Author(s) 2014.

  11. Heat driven pulse pump

    Science.gov (United States)

    Benner, Steve M (Inventor); Martins, Mario S. (Inventor)

    2000-01-01

    A heat driven pulse pump includes a chamber having an inlet port, an outlet port, two check valves, a wick, and a heater. The chamber may include a plurality of grooves inside wall of the chamber. When heated within the chamber, a liquid to be pumped vaporizes and creates pressure head that expels the liquid through the outlet port. As liquid separating means, the wick, disposed within the chamber, is to allow, when saturated with the liquid, the passage of only liquid being forced by the pressure head in the chamber, preventing the vapor from exiting from the chamber through the outlet port. A plurality of grooves along the inside surface wall of the chamber can sustain the liquid, which is amount enough to produce vapor for the pressure head in the chamber. With only two simple moving parts, two check valves, the heat driven pulse pump can effectively function over the long lifetimes without maintenance or replacement. For continuous flow of the liquid to be pumped a plurality of pumps may be connected in parallel.

  12. Dextrose boluses versus burette dextrose infusions in prevention of hypoglycemia among preterms admitted at Mulago Hospital: an open label randomized clinical trial.

    Science.gov (United States)

    Kutamba, E; Lubega, S; Mugalu, J; Ouma, J; Mupere, E

    2014-09-01

    Hypoglycemia is a major cause of morbidity and mortality among preterm infants and its management remains a challenge in resource limited settings. Use of dextrose infusion by the recommended infusion pumps is not feasible in our environment due to their high costs and yet the current use of mini dextrose boluses with syringes as adapted at Mulago national referral and tertiary teaching hospital has unknown efficacy in prevention of hypoglycemia. We determined the efficacy of dextrose infusions by burettes versus two hourly dextrose boluses in prevention of hypoglycemia among preterms admitted in the first 72 hours at Special Care Unit, Mulago Hospital. One hundred and forty preterms aged 0 to 24 hours of life were randomized to receive 10% IV dextrose either as mini boluses or by infusion using burettes in an open label clinical trial. Blood glucose was measured at 0, two hourly for next 6 hours, 6 hourly for next 12 hours and thereafter 12 hourly until end of 72 hours following admission. Primary end point was incidence of hypoglycemia (random blood sugar (RBS) dextrose infusion was computed using 1-RR. From February 2012 to April 2012, 68 preterms in the bolus arm and 72 in the infusion arm were studied. Hypoglycemia was detected in 34% (48/140). The incidence of hypoglycemia in the bolus arm was 59% (40/68) compared to 11% (8/72) in the infusion arm (RR; 0.19, 95% CI; 0.09-0.37). Efficacy (1-RR) of infusion by burettes versus boluses in prevention of hypoglycemia among preterms was 0.81 (95% CI; 0.63-0.90). Continuous 10% dextrose infusion by burettes reduced the incidence of hypoglycemia by 81% in the first 72 hours of admission compared to two hourly 10% mini dextrose boluses among preterms admitted at Special Care Unit, Mulago Hospital. (ClinicalTrials.gov Identifier: NCT01688674).

  13. Safe intravenous administration in pediatrics: A 5-year Pediatric Intensive Care Unit experience with smart pumps.

    Science.gov (United States)

    Manrique-Rodríguez, S; Sánchez-Galindo, A C; Fernández-Llamazares, C M; Calvo-Calvo, M M; Carrillo-Álvarez, Á; Sanjurjo-Sáez, M

    2016-10-01

    To estimate the impact of smart pump implementation in a pediatric intensive care unit in terms of number and type of administration errors intercepted. Observational, prospective study carried out from January 2010 to March 2015 with syringe and great volumen infusion pumps available in the hospital. A tertiary level hospital pediatric intensive care unit. Infusions delivered with infusion pumps in all pediatric intensive care unit patients. Design of a drug library with safety limits for all intravenous drugs prescribed. Users' compliance with drug library as well as number and type of errors prevented were analyzed. Two hundred and eighty-three errors were intercepted during 62 months of study. A high risk drug was involved in 58% of prevented errors, such as adrenergic agonists and antagonists, sedatives, analgesics, neuromuscular blockers, opioids, potassium and insulin. Users' average compliance with the safety software was 84%. Smart pumps implementation has proven effective in intercepting high risk drugs programming errors. These results might be exportable to other critical care units, involving pediatric or adult patients. Interdisciplinary colaboration is key to succeed in this process. Copyright © 2016 Elsevier España, S.L.U. y SEMICYUC. All rights reserved.

  14. Software Engineering Technology Infusion Within NASA

    Science.gov (United States)

    Zelkowitz, Marvin V.

    1996-01-01

    Abstract technology transfer is of crucial concern to both government and industry today. In this paper, several software engineering technologies used within NASA are studied, and the mechanisms, schedules, and efforts at transferring these technologies are investigated. The goals of this study are: 1) to understand the difference between technology transfer (the adoption of a new method by large segments of an industry) as an industry-wide phenomenon and the adoption of a new technology by an individual organization (called technology infusion); and 2) to see if software engineering technology transfer differs from other engineering disciplines. While there is great interest today in developing technology transfer models for industry, it is the technology infusion process that actually causes changes in the current state of the practice.

  15. Anaphylaxis after intravenous infusion of dexketoprofen trometamol

    Directory of Open Access Journals (Sweden)

    Sertac Guler

    2016-09-01

    Full Text Available Dexketoprofen trometamol (DT, a nonsteroidal anti-inflammatory drug, is a highly water-soluble salt and active enantiomer of rac-ketoprofen. Its parenteral form is commonly used for acute pain management in emergency departments of our country. Side effects such as diarrhea, indigestion, nausea, stomach pain, and vomiting may be seen after the use of DT. Anaphylactic shock (AS secondary to infusion of DT is very rare and, to our knowledge, it is the first case report describing this side effect. This case report was presented to emphasize that AS may be seen after the use of DT. Keywords: Anaphylactic shock, Dexketoprofen trometamol, Intravenous infusion (MeSH database

  16. Wet motor geroter fuel pump

    Energy Technology Data Exchange (ETDEWEB)

    Wiernicki, M.V.

    1987-05-05

    This patent describes a wet motor gerotor fuel pump for pumping fuel from a fuel source to an internal combustion which consists of: gerotor pump means comprising an inner pump gear, an outer pump gear, and second tang means located on one of the inner and outer pump gears. The second tang means further extends in a second radial direction radially offset from the first radial direction and forms a driving connection with the first tang means such that the fuel pump pumps fuel from the fuel source into the narrow conduit inlet chamber, through the gerotor pump means past the electric motor means into the outlet housing means substantially along the flow axis to the internal combustion engine.

  17. Infusion phlebitis assessment measures: a systematic review

    OpenAIRE

    Ray-Barruel, Gillian; Polit, Denise F; Murfield, Jenny E; Rickard, Claire M

    2014-01-01

    Rationale, aims and objectives Phlebitis is a common and painful complication of peripheral intravenous cannulation. The aim of this review was to identify the measures used in infusion phlebitis assessment and evaluate evidence regarding their reliability, validity, responsiveness and feasibility. Method We conducted a systematic literature review of the Cochrane library, Ovid MEDLINE and EBSCO CINAHL until September 2013. All English-language studies (randomized controlled trials, prospecti...

  18. Fusion reactor pumped laser

    International Nuclear Information System (INIS)

    Jassby, D.L.

    1988-01-01

    A nuclear pumped laser is described comprising: a toroidal fusion reactor, the reactor generating energetic neutrons; an annular gas cell disposed around the outer periphery of the reactor, the cell including an annular reflecting mirror disposed at the bottom of the cell and an annular output window disposed at the top of the cell; a gas lasing medium disposed within the annular cell for generating output laser radiation; neutron reflector material means disposed around the annular cell for reflecting neutrons incident thereon back into the gas cell; neutron moderator material means disposed between the reactor and the gas cell and between the gas cell and the neutron reflector material for moderating the energy of energetic neutrons from the reactor; converting means for converting energy from the moderated neutrons to energy pumping means for pumping the gas lasing medium; and beam compactor means for receiving output laser radiation from the annular output window and generating a single output laser beam therefrom

  19. Infusion phlebitis assessment measures: a systematic review.

    Science.gov (United States)

    Ray-Barruel, Gillian; Polit, Denise F; Murfield, Jenny E; Rickard, Claire M

    2014-04-01

    Phlebitis is a common and painful complication of peripheral intravenous cannulation. The aim of this review was to identify the measures used in infusion phlebitis assessment and evaluate evidence regarding their reliability, validity, responsiveness and feasibility. We conducted a systematic literature review of the Cochrane library, Ovid MEDLINE and EBSCO CINAHL until September 2013. All English-language studies (randomized controlled trials, prospective cohort and cross-sectional) that used an infusion phlebitis scale were retrieved and analysed to determine which symptoms were included in each scale and how these were measured. We evaluated studies that reported testing the psychometric properties of phlebitis assessment scales using the COnsensus-based Standards for the selection of health Measurement INstruments (COSMIN) guidelines. Infusion phlebitis was the primary outcome measure in 233 studies. Fifty-three (23%) of these provided no actual definition of phlebitis. Of the 180 studies that reported measuring phlebitis incidence and/or severity, 101 (56%) used a scale and 79 (44%) used a definition alone. We identified 71 different phlebitis assessment scales. Three scales had undergone some psychometric analyses, but no scale had been rigorously tested. Many phlebitis scales exist, but none has been thoroughly validated for use in clinical practice. A lack of consensus on phlebitis measures has likely contributed to disparities in reported phlebitis incidence, precluding meaningful comparison of phlebitis rates. © 2014 The Authors. Journal of Evaluation in Clinical Practice published by John Wiley & Sons, Ltd.

  20. Regenerative adsorbent heat pump

    Science.gov (United States)

    Jones, Jack A. (Inventor)

    1991-01-01

    A regenerative adsorbent heat pump process and system is provided which can regenerate a high percentage of the sensible heat of the system and at least a portion of the heat of adsorption. A series of at least four compressors containing an adsorbent is provided. A large amount of heat is transferred from compressor to compressor so that heat is regenerated. The process and system are useful for air conditioning rooms, providing room heat in the winter or for hot water heating throughout the year, and, in general, for pumping heat from a lower temperature to a higher temperature.

  1. Acoustical heat pumping engine

    Science.gov (United States)

    Wheatley, J.C.; Swift, G.W.; Migliori, A.

    1983-08-16

    The disclosure is directed to an acoustical heat pumping engine without moving seals. A tubular housing holds a compressible fluid capable of supporting an acoustical standing wave. An acoustical driver is disposed at one end of the housing and the other end is capped. A second thermodynamic medium is disposed in the housing near to but spaced from the capped end. Heat is pumped along the second thermodynamic medium toward the capped end as a consequence both of the pressure oscillation due to the driver and imperfect thermal contact between the fluid and the second thermodynamic medium. 2 figs.

  2. Geothermal heat pump performance

    Energy Technology Data Exchange (ETDEWEB)

    Boyd, Tonya L.; Lienau, Paul J.

    1995-01-01

    Geothermal heat pump systems are a promising new energy technology that has shown rapid increase in usage over the past ten years in the United States. These systems offer substantial benefits to customers and utilities in energy (kWh) and demand (kW) savings. The purpose of this study was to determine what existing monitored data was available mainly from electric utilities on heat pump performance, energy savings and demand reduction for residential, school, and commercial building applications. Information was developed on the status of electric utility marketing programs, barriers to market penetration, incentive programs, and benefits.

  3. Geothermal Heat Pump Performance

    Energy Technology Data Exchange (ETDEWEB)

    Boyd, Tonya L.; Lienau, Paul J.

    1995-01-01

    Geothermal heat pump systems are a promising new energy technology that has shown rapid increase in usage over the past ten years in the United States. These systems offer substantial benefits to customers and utilities in energy (kWh) and demand (kW) savings. The purpose of this study was to determine what existing monitored data was available mainly from electric utilities on heat pump performance, energy savings and demand reduction for residential, school, and commercial building applications. Information was developed on the status of electric utility marketing programs, barriers to market penetration, incentive programs, and benefits.

  4. Heat pump planning handbook

    CERN Document Server

    Bonin, Jürgen

    2015-01-01

    The Heat Pump Planning Handbook contains practical information and guidance on the design, planning and selection of heat pump systems, allowing engineers, designers, architects and construction specialists to compare a number of different systems and options. Including detailed descriptions of components and their functions and reflecting the current state of technology this guide contains sample tasks and solutions as well as new model calculations and planning evaluations. Also economic factors and alternative energy sources are covered, which are essential at a time of rising heat costs. T

  5. Carbon sheet pumping

    International Nuclear Information System (INIS)

    Ohyabu, N.; Sagara, A.; Kawamura, T.; Motojima, O.; Ono, T.

    1993-07-01

    A new hydrogen pumping scheme has been proposed which controls recycling of the particles for significant improvement of the energy confinement in toroidal magnetic fusion devices. In this scheme, a part of the vacuum vessel surface near the divertor is covered with carbon sheets of a large surface area. Before discharge initiation, the sheets are baked up to 700 ∼ 1000degC to remove the previously trapped hydrogen atoms. After being cooled down to below ∼ 200degC, the unsaturated carbon sheets trap high energy charge exchange hydrogen atoms effectively during a discharge and overall pumping efficiency can be as high as ∼ 50 %. (author)

  6. Effect of Insulin Infusion on Liver Protein Synthesis during Hemodialysis

    DEFF Research Database (Denmark)

    Reinhard, Mark; Frystyk, Jan; Jespersen, Bente

    2011-01-01

    Background Hemodialysis (HD) is a catabolic procedure that may contribute to the high frequency of protein-energy wasting among patients receiving maintenance HD. The present study investigated the additional effect of glucose and glucose-insulin infusion on liver protein synthesis during HD...... compared with a meal alone. Methods In a randomized cross-over study with three arms, 11 non-diabetic HD patients were assigned to receive a conventional HD session with either: • no treatment (NT) • IV infusion of glucose (G) • IV infusion of glucose-insulin (GI) During infusions blood glucose levels were...... maintained at 8.0-10.0 mmol/L by additional glucose infusion. Glucose and glucose-insulin infusions were commenced 2 h prior to HD and continued throughout the HD session. Fasting blood samples were collected at baseline before infusion and followed by the only meal allowed during the study. Results Blood...

  7. Vacuum pumping concepts for ETF

    International Nuclear Information System (INIS)

    Homeyer, W.G.

    1980-09-01

    The Engineering Test Facility (ETF) poses unique vacuum pumping requirements due to its large size and long burn characteristics. These requirements include torus vacuum pumping initially and between burns and pumping of neutralized gas from divertor collector chambers. It was found that the requirements could be met by compound cryopumps in which molecular sieve 5A is used as the cryosorbent. The pumps, ducts, and vacuum valves required are large but fit with other ETF components and do not require major advances in vacuum pumping technology. Several additional design, analytical, and experimental studies were identified as needed to optimize designs and provide better design definition for the ETF vacuum pumping systems

  8. Volumetric fat-water separated T2-weighted MRI

    International Nuclear Information System (INIS)

    Vasanawala, Shreyas S.; Sonik, Arvind; Madhuranthakam, Ananth J.; Venkatesan, Ramesh; Lai, Peng; Brau, Anja C.S.

    2011-01-01

    Pediatric body MRI exams often cover multiple body parts, making the development of broadly applicable protocols and obtaining uniform fat suppression a challenge. Volumetric T2 imaging with Dixon-type fat-water separation might address this challenge, but it is a lengthy process. We develop and evaluate a faster two-echo approach to volumetric T2 imaging with fat-water separation. A volumetric spin-echo sequence was modified to include a second shifted echo so two image sets are acquired. A region-growing reconstruction approach was developed to decompose separate water and fat images. Twenty-six children were recruited with IRB approval and informed consent. Fat-suppression quality was graded by two pediatric radiologists and compared against conventional fat-suppressed fast spin-echo T2-W images. Additionally, the value of in- and opposed-phase images was evaluated. Fat suppression on volumetric images had high quality in 96% of cases (95% confidence interval of 80-100%) and were preferred over or considered equivalent to conventional two-dimensional fat-suppressed FSE T2 imaging in 96% of cases (95% confidence interval of 78-100%). In- and opposed-phase images had definite value in 12% of cases. Volumetric fat-water separated T2-weighted MRI is feasible and is likely to yield improved fat suppression over conventional fat-suppressed T2-weighted imaging. (orig.)

  9. Volumetric image interpretation in radiology: scroll behavior and cognitive processes.

    Science.gov (United States)

    den Boer, Larissa; van der Schaaf, Marieke F; Vincken, Koen L; Mol, Chris P; Stuijfzand, Bobby G; van der Gijp, Anouk

    2018-05-16

    The interpretation of medical images is a primary task for radiologists. Besides two-dimensional (2D) images, current imaging technologies allow for volumetric display of medical images. Whereas current radiology practice increasingly uses volumetric images, the majority of studies on medical image interpretation is conducted on 2D images. The current study aimed to gain deeper insight into the volumetric image interpretation process by examining this process in twenty radiology trainees who all completed four volumetric image cases. Two types of data were obtained concerning scroll behaviors and think-aloud data. Types of scroll behavior concerned oscillations, half runs, full runs, image manipulations, and interruptions. Think-aloud data were coded by a framework of knowledge and skills in radiology including three cognitive processes: perception, analysis, and synthesis. Relating scroll behavior to cognitive processes showed that oscillations and half runs coincided more often with analysis and synthesis than full runs, whereas full runs coincided more often with perception than oscillations and half runs. Interruptions were characterized by synthesis and image manipulations by perception. In addition, we investigated relations between cognitive processes and found an overall bottom-up way of reasoning with dynamic interactions between cognitive processes, especially between perception and analysis. In sum, our results highlight the dynamic interactions between these processes and the grounding of cognitive processes in scroll behavior. It suggests, that the types of scroll behavior are relevant to describe how radiologists interact with and manipulate volumetric images.

  10. Aspects of volumetric efficiency measurement for reciprocating engines

    Directory of Open Access Journals (Sweden)

    Pešić Radivoje B.

    2013-01-01

    Full Text Available The volumetric efficiency significantly influences engine output. Both design and dimensions of an intake and exhaust system have large impact on volumetric efficiency. Experimental equipment for measuring of airflow through the engine, which is placed in the intake system, may affect the results of measurements and distort the real picture of the impact of individual structural factors. This paper deals with the problems of experimental determination of intake airflow using orifice plates and the influence of orifice plate diameter on the results of the measurements. The problems of airflow measurements through a multi-process Otto/Diesel engine were analyzed. An original method for determining volumetric efficiency was developed based on in-cylinder pressure measurement during motored operation, and appropriate calibration of the experimental procedure was performed. Good correlation between the results of application of the original method for determination of volumetric efficiency and the results of theoretical model used in research of influence of the intake pipe length on volumetric efficiency was determined. [Acknowledgments. The paper is the result of the research within the project TR 35041 financed by the Ministry of Science and Technological Development of the Republic of Serbia

  11. Insulin pump therapy in children with type 1 diabetes

    DEFF Research Database (Denmark)

    Szypowska, Agnieszka; Schwandt, Anke; Svensson, Jannet

    2016-01-01

    BACKGROUND: Intensified insulin delivery using multiple daily injections (MDI) or continuous subcutaneous insulin infusion (CSII) is recommended in children with type 1 diabetes (T1D) to achieve good metabolic control. OBJECTIVE: To examine the frequency of pump usage in T1D children treated...... in SWEET (Better control in Paediatric and Adolescent diabeteS: Working to crEate CEnTers of Reference) centers and to compare metabolic control between patients treated with CSII vs MDI. METHODS: This study included 16 570 T1D children participating in the SWEET prospective, multicenter, standardized...... is offered by most Sweet centers. The differences between centers affect the frequency of use of modern technology. Despite the heterogeneity of centers, T1D children achieve relatively good metabolic control, especially those treated with insulin pumps and those of younger age....

  12. Effects of chronic infusion of a GABAA receptor agonist or antagonist into the vestibular nuclear complex on vestibular compensation in the guinea pig.

    Science.gov (United States)

    Gliddon, Catherine M; Darlington, Cynthia L; Smith, Paul F

    2005-06-01

    The aim of this study was to determine the effects of chronic infusion of a GABA(A) receptor agonist/antagonist into the ipsilateral or contralateral vestibular nuclear complex (VNC) on vestibular compensation, the process of behavioral recovery that occurs after unilateral vestibular deafferentation (UVD). This was achieved by a mini-osmotic pump that infused, over 30 h, muscimol or gabazine into the ipsilateral or contralateral VNC. Spontaneous nystagmus (SN), yaw head tilt (YHT), and roll head tilt (RHT) were measured. Infusion of muscimol or gabazine into either the ipsilateral or the contralateral VNC had little effect on SN compensation. In contrast, infusion of muscimol (250, 500, and 750 ng) into the contralateral VNC and gabazine (31.25, 62.5, and 125 ng) into the ipsilateral VNC significantly affected YHT and RHT (p 0.05). Interestingly, the effects of muscimol and gabazine on YHT and RHT were consistent throughout the first 30 h post-UVD. Infusion of muscimol (62.5, 125, and 250 ng) into the ipsilateral VNC and gabazine (125, 375, and 750 ng) into the contralateral VNC had little effect on YHT and RHT or their rate of compensation. These results suggest that the ipsilateral gabazine and contralateral muscimol infusions are modifying the expression of the symptoms without altering the mechanism of compensation. Furthermore, the neurochemical mechanism responsible for vestibular compensation can cope with the both the GABA(A) receptor-mediated and the UVD-induced decrease in resting activity.

  13. Study of Hydrogen Pumping through Condensed Argon in Cryogenic pump

    International Nuclear Information System (INIS)

    Jadeja, K A; Bhatt, S B

    2012-01-01

    In ultra high vacuum (UHV) range, hydrogen is a dominant residual gas in vacuum chamber. Hydrogen, being light gas, pumping of hydrogen in this vacuum range is limited with widely used UHV pumps, viz. turbo molecular pump and cryogenic pump. Pre condensed argon layers in cryogenic pump create porous structure on the surface of the pump, which traps hydrogen gas at a temperature less than 20° K. Additional argon gas injection in the cryogenic pump, at lowest temperature, generates multiple layers of condensed argon as a porous frost with 10 to 100 A° diameters pores, which increase the pumping capacity of hydrogen gas. This pumping mechanism of hydrogen is more effective, to pump more hydrogen gas in UHV range applicable in accelerator, space simulation etc. and where hydrogen is used as fuel gas like tokamak. For this experiment, the cryogenic pump with a closed loop refrigerator using helium gas is used to produce the minimum cryogenic temperature as ∼ 14° K. In this paper, effect of cryosorption of hydrogen is presented with different levels of argon gas and hydrogen gas in cryogenic pump chamber.

  14. Solar pumped laser

    Science.gov (United States)

    Lee, J. H.; Hohl, F.; Weaver, W. R. (Inventor)

    1984-01-01

    A solar pumped laser is described in which the lasant is a gas that will photodissociate and lase when subjected to sunrays. Sunrays are collected and directed onto the gas lasant to cause it to lase. Applications to laser propulsion and laser power transmission are discussed.

  15. Cryogenic vacuum pump design

    International Nuclear Information System (INIS)

    Bartlett, A.J.; Lessard, P.A.

    1984-01-01

    This paper is a review of the problems and tradeoffs involved in cryogenic vacuum pump analysis, design and manufacture. Particular attention is paid to the several issues unique to cryopumps, e.g., radiation loading, adsorption of noncondensible gases, and regeneration. A general algorithm for cryopump design is also proposed. 12 references

  16. Pump monitoring and analysis

    International Nuclear Information System (INIS)

    Guy, K.R.

    1992-01-01

    The paper describes how to set up a periodic vibration monitoring program implemented with electronic data loggers. Acquired data will be analyzed and evaluated to determine pump condition. Periodic measuring frequency, reporting procedures, and conditions of mechanical components are discussed in detail based on the actual case study

  17. Magnetic-flux pump

    Science.gov (United States)

    Hildebrandt, A. F.; Elleman, D. D.; Whitmore, F. C. (Inventor)

    1966-01-01

    A magnetic flux pump is described for increasing the intensity of a magnetic field by transferring flux from one location to the magnetic field. The device includes a pair of communicating cavities formed in a block of superconducting material, and a piston for displacing the trapped magnetic flux into the secondary cavity producing a field having an intense flux density.

  18. Putzmeister pumps for Tchernobyl

    International Nuclear Information System (INIS)

    Anon.

    1986-01-01

    Self-propelling concrete pumps are briefly described in this article, they comprise a 52-meter boom, a radiation protection, remote control, videocameras. Several units were ordered by the Soviet Union. The truck cabin is protected against radiation by a 10 millimeter thick shield in lead. 3 photographs [fr

  19. Scroll vacuum pump

    Energy Technology Data Exchange (ETDEWEB)

    Morishita, Etsuo; Suganami, Takuya; Nishida, Mitsuhiro; Kitora, Yoshihisa; Yamamoto, Sakuei; Fujii, Kosaburo

    1988-02-25

    An effort is made to apply a scroll machine to development of a vacuum pump. In view of mechanical simplification and load patterns, the vacuum pump uses a rotating mechanism to produce paired vortices rotating around each center. Chip seal and atmospheric pressure are utilized for axial gap sealing while a spring and atmospheric pressure for the radial gap sealing. In both gaps, the sealing direction is stationary relative to the environment during rotation, making it much easier to achieve effective sealing as compared to oscillating pumps. Since the compression ratio is high in vacuum pumps, a zero top clearance form is adopted for the central portion of vortices and an gas release valve is installed in the rotating axis. A compact Oldham coupling with a small inertia force is installed behind the vortices to maintain the required phase relations between the vortices. These improvements result in a vacuum of 1 Pa for dry operation and 10/sup -2/ Pa for oil flooded operation of a single-stage scroll machine at 1800 rpm. (5 figs, 1 tab, 4 refs)

  20. Centrifugal blood pump 603

    Indian Academy of Sciences (India)

    Centrifugal blood pump 603 pressure obtained for real blood, as shown in figure 6, is a little higher than that for glycerin aqua Solution with the same viscosity as blood. This may indicate the effect of slight non-. Newtonian turbulent flow. The radial whirl motion of the impeller was observed by dual laser position sensors.

  1. Full-spectrum volumetric solar thermal conversion via photonic nanofluids.

    Science.gov (United States)

    Liu, Xianglei; Xuan, Yimin

    2017-10-12

    Volumetric solar thermal conversion is an emerging technique for a plethora of applications such as solar thermal power generation, desalination, and solar water splitting. However, achieving broadband solar thermal absorption via dilute nanofluids is still a daunting challenge. In this work, full-spectrum volumetric solar thermal conversion is demonstrated over a thin layer of the proposed 'photonic nanofluids'. The underlying mechanism is found to be the photonic superposition of core resonances, shell plasmons, and core-shell resonances at different wavelengths, whose coexistence is enabled by the broken symmetry of specially designed composite nanoparticles, i.e., Janus nanoparticles. The solar thermal conversion efficiency can be improved by 10.8% compared with core-shell nanofluids. The extinction coefficient of Janus dimers with various configurations is also investigated to unveil the effects of particle couplings. This work provides the possibility to achieve full-spectrum volumetric solar thermal conversion, and may have potential applications in efficient solar energy harvesting and utilization.

  2. Volumetric display using a roof mirror grid array

    Science.gov (United States)

    Miyazaki, Daisuke; Hirano, Noboru; Maeda, Yuuki; Ohno, Keisuke; Maekawa, Satoshi

    2010-02-01

    A volumetric display system using a roof mirror grid array (RMGA) is proposed. The RMGA consists of a two-dimensional array of dihedral corner reflectors and forms a real image at a plane-symmetric position. A two-dimensional image formed with a RMGA is moved at thigh speed by a mirror scanner. Cross-sectional images of a three-dimensional object are displayed in accordance with the position of the image plane. A volumetric image can be observed as a stack of the cross-sectional images by high-speed scanning. Image formation by a RMGA is free from aberrations. Moreover, a compact optical system can be constructed because a RMGA doesn't have a focal length. An experimental volumetric display system using a galvanometer mirror and a digital micromirror device was constructed. The formation of a three-dimensional image consisting of 1024 × 768 × 400 voxels is confirmed by the experimental system.

  3. Extended infusion versus intermittent infusion of imipenem in the treatment of ventilator-associated pneumonia.

    Science.gov (United States)

    Ibrahim, Mohamed M; Tammam, Tarek Fouad; Ebaed, Mohy El Deen; Sarhan, Hatem A; Gad, Gamal F; Hussein, Amal K

    2017-01-01

    Mechanical ventilation support can be the main source of ventilator-associated pneumonia (VAP). VAP is a serious infection that may be associated with dangerous gram-negative bacteria mainly, and it leads to an increase in the mortality in the intensive care unit (ICU). Imipenem is one of the strongest antibiotics now available for treating VAP which is associated with gram-negative and gram-positive bacteria, and it belongs to beta-lactam antibiotic group (carbapenem). This study tried to investigate the efficacy of imipenem against VAP when it was infused within 180 min versus the efficacy when it was infused within 30-60 min. This study was conducted in main ICU in general hospital which consists of surgical and medical beds within 2 years. One hundred and eighty-seven patients were enrolled on it. This study is a retrospective cohort which was conducted within 2 years. The efficacy of imipenem which was administered by intermittent infusion (30-60 min) within first year was compared with the efficacy of imipenem which was administered by extended infusion (180 min) within second year in the field of VAP curing and cost reduction. All data were collected retrospectively from patient medical files and were statistically analyzed by SPSS version 20. The study was designed to measure clinical and cost reduction outcomes, mortality and hospital stay. The results indicated that there is a significant decrease in mortality, number of recurrent infection, and ICU stay length, and the number of mechanical ventilator days was associated with extended imipenem infusion during the second year of the study. The use of imipenem with extended infusion over 3 hours enhances its clinical outcomes in the treatment of VAP.

  4. Impulse pumping modelling and simulation

    International Nuclear Information System (INIS)

    Pierre, B; Gudmundsson, J S

    2010-01-01

    Impulse pumping is a new pumping method based on propagation of pressure waves. Of particular interest is the application of impulse pumping to artificial lift situations, where fluid is transported from wellbore to wellhead using pressure waves generated at wellhead. The motor driven element of an impulse pumping apparatus is therefore located at wellhead and can be separated from the flowline. Thus operation and maintenance of an impulse pump are facilitated. The paper describes the different elements of an impulse pumping apparatus, reviews the physical principles and details the modelling of the novel pumping method. Results from numerical simulations of propagation of pressure waves in water-filled pipelines are then presented for illustrating impulse pumping physical principles, and validating the described modelling with experimental data.

  5. Reactor recirculation pump test loop

    International Nuclear Information System (INIS)

    Taka, Shusei; Kato, Hiroyuki

    1979-01-01

    A test loop for a reactor primary loop recirculation pumps (PLR pumps) has been constructed at Ebara's Haneda Plant in preparation for production of PLR pumps under license from Byron Jackson Pump Division of Borg-Warner Corporation. This loop can simulate operating conditions for test PLR pumps with 130 per cent of the capacity of pumps for a 1100 MWe BWR plant. A main loop, primary cooling system, water demineralizer, secondary cooling system, instrumentation and control equipment and an electric power supply system make up the test loop. This article describes the test loop itself and test results of two PLR pumps for Fukushima No. 2 N.P.S. Unit 1 and one main circulation pump for HAZ Demonstration Test Facility. (author)

  6. Gradients estimation from random points with volumetric tensor in turbulence

    Science.gov (United States)

    Watanabe, Tomoaki; Nagata, Koji

    2017-12-01

    We present an estimation method of fully-resolved/coarse-grained gradients from randomly distributed points in turbulence. The method is based on a linear approximation of spatial gradients expressed with the volumetric tensor, which is a 3 × 3 matrix determined by a geometric distribution of the points. The coarse grained gradient can be considered as a low pass filtered gradient, whose cutoff is estimated with the eigenvalues of the volumetric tensor. The present method, the volumetric tensor approximation, is tested for velocity and passive scalar gradients in incompressible planar jet and mixing layer. Comparison with a finite difference approximation on a Cartesian grid shows that the volumetric tensor approximation computes the coarse grained gradients fairly well at a moderate computational cost under various conditions of spatial distributions of points. We also show that imposing the solenoidal condition improves the accuracy of the present method for solenoidal vectors, such as a velocity vector in incompressible flows, especially when the number of the points is not large. The volumetric tensor approximation with 4 points poorly estimates the gradient because of anisotropic distribution of the points. Increasing the number of points from 4 significantly improves the accuracy. Although the coarse grained gradient changes with the cutoff length, the volumetric tensor approximation yields the coarse grained gradient whose magnitude is close to the one obtained by the finite difference. We also show that the velocity gradient estimated with the present method well captures the turbulence characteristics such as local flow topology, amplification of enstrophy and strain, and energy transfer across scales.

  7. Cost-effectiveness of volumetric alcohol taxation in Australia.

    Science.gov (United States)

    Byrnes, Joshua M; Cobiac, Linda J; Doran, Christopher M; Vos, Theo; Shakeshaft, Anthony P

    2010-04-19

    To estimate the potential health benefits and cost savings of an alcohol tax rate that applies equally to all alcoholic beverages based on their alcohol content (volumetric tax) and to compare the cost savings with the cost of implementation. Mathematical modelling of three scenarios of volumetric alcohol taxation for the population of Australia: (i) no change in deadweight loss, (ii) no change in tax revenue, and (iii) all alcoholic beverages taxed at the same rate as spirits. Estimated change in alcohol consumption, tax revenue and health benefit. The estimated cost of changing to a volumetric tax rate is $18 million. A volumetric tax that is deadweight loss-neutral would increase the cost of beer and wine and reduce the cost of spirits, resulting in an estimated annual increase in taxation revenue of $492 million and a 2.77% reduction in annual consumption of pure alcohol. The estimated net health gain would be 21 000 disability-adjusted life-years (DALYs), with potential cost offsets of $110 million per annum. A tax revenue-neutral scenario would result in an 0.05% decrease in consumption, and a tax on all alcohol at a spirits rate would reduce consumption by 23.85% and increase revenue by $3094 million [corrected]. All volumetric tax scenarios would provide greater health benefits and cost savings to the health sector than the existing taxation system, based on current understandings of alcohol-related health effects. An equalized volumetric tax that would reduce beer and wine consumption while increasing the consumption of spirits would need to be approached with caution. Further research is required to examine whether alcohol-related health effects vary by type of alcoholic beverage independent of the amount of alcohol consumed to provide a strong evidence platform for alcohol taxation policies.

  8. Coolability of volumetrically heated particle beds

    Energy Technology Data Exchange (ETDEWEB)

    Rashid, Muhammad

    2017-03-22

    In case of a severe nuclear reactor accident, with loss of coolant, a particle bed may be formed from the fragmentation of the molten core in the residual water at different stages of the accident. To avoid further propagation of the accident and maintain the integrity of the reactor pressure vessel, the decay heat of the particle bed must be removed. To better understand the various thermo-hydraulic processes within such heat-generating particle beds, the existing DEBRIS test facility at IKE has been modified to be able to perform novel boiling, dryout and quenching experiments. The essential experimental data includes the pressure gradients measured by 8 differential pressure transducers along the bed height as a function of liquid and vapour superficial velocities, the determination of local dryout heat fluxes for different system pressures as well as the local temperature distribution measured by a set of 51 thermocouples installed inside the particle bed. The experiments were carried out for two different particle beds: a polydispersed particle bed which consisted of stainless steel balls (2 mm, 3 mm and 6 mm diameters) and an irregular particle bed which consisted of a mixture of steel balls (3 mm and 6 mm) and irregularly shaped Al{sub 2}O{sub 3} particles. Additionally, all experiments were carried out for different flow conditions, such as the reference case of passive 1D top-flooding, 1D bottom flooding (driven by external pumps and different downcomer configurations) and 2D top-/bottom-/lateral flooding with a perforated downcomer. In this work, it has been observed that for both particle beds with downcomer configurations an open downcomer leads to the best coolability (dryout heat flux = 1560 kW/m{sup 2}, polydispersed particle bed, psys = 1 bar) of the particle bed, mainly due to bottom-flow with enhanced natural convection. It has also been shown that a potential lateral flow via a perforation of the downcomer does not bring any further improvements

  9. Coolability of volumetrically heated particle beds

    International Nuclear Information System (INIS)

    Rashid, Muhammad

    2017-01-01

    In case of a severe nuclear reactor accident, with loss of coolant, a particle bed may be formed from the fragmentation of the molten core in the residual water at different stages of the accident. To avoid further propagation of the accident and maintain the integrity of the reactor pressure vessel, the decay heat of the particle bed must be removed. To better understand the various thermo-hydraulic processes within such heat-generating particle beds, the existing DEBRIS test facility at IKE has been modified to be able to perform novel boiling, dryout and quenching experiments. The essential experimental data includes the pressure gradients measured by 8 differential pressure transducers along the bed height as a function of liquid and vapour superficial velocities, the determination of local dryout heat fluxes for different system pressures as well as the local temperature distribution measured by a set of 51 thermocouples installed inside the particle bed. The experiments were carried out for two different particle beds: a polydispersed particle bed which consisted of stainless steel balls (2 mm, 3 mm and 6 mm diameters) and an irregular particle bed which consisted of a mixture of steel balls (3 mm and 6 mm) and irregularly shaped Al 2 O 3 particles. Additionally, all experiments were carried out for different flow conditions, such as the reference case of passive 1D top-flooding, 1D bottom flooding (driven by external pumps and different downcomer configurations) and 2D top-/bottom-/lateral flooding with a perforated downcomer. In this work, it has been observed that for both particle beds with downcomer configurations an open downcomer leads to the best coolability (dryout heat flux = 1560 kW/m 2 , polydispersed particle bed, psys = 1 bar) of the particle bed, mainly due to bottom-flow with enhanced natural convection. It has also been shown that a potential lateral flow via a perforation of the downcomer does not bring any further improvements in

  10. Sludge pumping in water treatment

    International Nuclear Information System (INIS)

    Solar Manuel, M. A.

    2010-01-01

    In water treatment processes is frequent to separate residual solids, with sludge shape, and minimize its volume in a later management. the technologies to applicate include pumping across pipelines, even to long distance. In wastewater treatment plants (WWTP), the management of these sludges is very important because their characteristics affect load losses calculation. Pumping sludge can modify its behavior and pumping frequency can concern treatment process. This paper explains advantages and disadvantages of different pumps to realize transportation sludge operations. (Author) 11 refs.

  11. Vivitron dead section pumping tests

    International Nuclear Information System (INIS)

    Heugel, J.; Bayet, J.P.; Brandt, C.; Delhomme, C.; Krieg, C.; Kustner, F.; Meiss, R.; Riehl, R.; Roth, C.; Schlewer, B.; Six, P.; Weber, A.

    1990-10-01

    Pumping tests have been conducted on a simulated accelerator dead section. The behavior of different pump types are compared and analyzed. Vacuum conditions to be expected in the Vivitron are reached and several parameters are verified. Selection of a pump for the Vivitron dead section is confirmed

  12. Heat pumps are a dream

    Energy Technology Data Exchange (ETDEWEB)

    1981-12-01

    The fact that heat pumps do not achieve what their manufacturers promise in costs efficiency has been realized by the market. In 1981 the sales of heat pumps decreased by 50% of the 1980 market. Public utilities give the reason as economic, since fuel oil is too cheap. The author refutes this argument and presents arguments against heat pumps.

  13. The role of elastomeric pumps in postoperative analgesia in orthopaedics and factors affecting their flow rate.

    Science.gov (United States)

    Theodorides, Anthony Andreas

    2017-12-01

    Elastomeric pumps are mechanical devices composed of an elastomeric balloon reservoir into which the drug to be infused is stored, a protective casing (used by some manufacturers), a flow controller and a wound catheter. In orthopaedics they are used to provide continuous local infiltration analgesia. In this way patients rely less on other routes of analgesia and thus avoid their systemic side effects. Studies have shown good response to analgesia with these pumps for the first 24 hours but their benefit is not as clear at 48 and 72 hours. There are numerous factors that affect the flow rate of elastomeric pumps. Some are inherent to all elastomeric pumps such as: the pressure exerted by the elastomeric balloon, catheter size, the vertical height of the pump in relation to the wound, viscosity and partial filling. There are also other factors which vary according to the manufacturer such as: the optimal temperature to obtain the desired flow rate as this directly affects viscosity, the dialysate that the analgesic drug is mixed with (ie normal saline or 5% dextrose), and the storage conditions of the fluid to be infused. It is thus essential to follow the clinical guidelines provided by the manufacturer in order to obtain the desired flow rate. Copyright the Association for Perioperative Practice.

  14. Anaphylaxis after intravenous infusion of dexketoprofen trometamol.

    Science.gov (United States)

    Guler, Sertac; Ertok, Ilyas; Sahin, Nurdan Yilmaz; Ramadan, Hayri; Katirci, Yavuz

    2016-09-01

    Dexketoprofen trometamol (DT), a nonsteroidal anti-inflammatory drug, is a highly water-soluble salt and active enantiomer of rac-ketoprofen. Its parenteral form is commonly used for acute pain management in emergency departments of our country. Side effects such as diarrhea, indigestion, nausea, stomach pain, and vomiting may be seen after the use of DT. Anaphylactic shock (AS) secondary to infusion of DT is very rare and, to our knowledge, it is the first case report describing this side effect. This case report was presented to emphasize that AS may be seen after the use of DT.

  15. Pumping characteristics of roots blower pumps for light element gases

    International Nuclear Information System (INIS)

    Hiroki, Seiji; Abe, Tetsuya; Tanzawa, Sadamitsu; Nakamura, Jun-ichi; Ohbayashi, Tetsuro

    2002-07-01

    The pumping speed and compression ratio of the two-stage roots blower pumping system were measured for light element gases (H 2 , D 2 and He) and for N 2 , in order to assess validity of the ITER torus roughing system as an ITER R and D task (T234). The pumping system of an Edwards EH1200 (nominal pumping speed of 1200 m 3 /s), two EH250s (ibid. 250 m 3 /s) and a backing pump (ibid. 100 m 3 /s) in series connection was tested under PNEUROP standards. The maximum pumping speeds of the two-stage system for D 2 and N 2 were 1200 and 1300 m 3 /h, respectively at 60 Hz, which satisfied the nominal pumping speed. These experimental data support the design validity of the ITER torus roughing system. (author)

  16. Position Statement on the management of continuous subcutaneous insulin infusion (CSII): The Italian Lazio experience.

    Science.gov (United States)

    Maurizi, Anna R; Suraci, Concetta; Pitocco, Dario; Schiaffini, Riccardo; Tubili, Claudio; Morviducci, Lelio; Giordano, Renato; Manfrini, Silvia; Lauro, Davide; Frontoni, Simona; Pozzilli, Paolo; Buzzetti, Raffaella

    2016-01-01

    This document has been developed by a group of Italian diabetologists with extensive experience in continuous subcutaneous insulin infusion (CSII) therapy to provide indications for the clinical management of CSII in diabetic patients (both type 1 and type 2) based on delivery mode operating in Italy. Although the potential benefits of pump therapy in achieving glycemic goals is now accepted, such results cannot be obtained without specific knowledge and skills being conveyed to patients during ad hoc educational training. To ensure that these new technologies reach their full effectiveness, as demonstrated theoretically and clinically, a careful assessment of the overall therapeutic and educational process is required, in both qualitative and quantitative terms. Therefore, to ensure the cost-effectiveness of insulin pump therapy and to justify reimbursement of therapy costs by the National Health System in Italy, in this article we present a model for diabetes and healthcare centers to follow that provides for different levels of expertise in the field of CSII therapy. This model will guarantee the provision of excellent care during insulin pump therapies, thus representing the basis for a successful outcome and expansion of this form of insulin treatment in patients with diabetes while also keeping costs under control. © 2015 Ruijin Hospital, Shanghai Jiaotong University School of Medicine and Wiley Publishing Asia Pty Ltd.

  17. Electroosmotic pumps for microflow analysis

    Science.gov (United States)

    Wang, Xiayan; Wang, Shili; Gendhar, Brina; Cheng, Chang; Byun, Chang Kyu; Li, Guanbin; Zhao, Meiping; Liu, Shaorong

    2009-01-01

    With rapid development in microflow analysis, electroosmotic pumps are receiving increasing attention. Compared to other micropumps, electroosmotic pumps have several unique features. For example, they are bi-directional, can generate constant and pulse-free flows with flow rates well suited to microanalytical systems, and can be readily integrated with lab-on-chip devices. The magnitude and the direction of flow of an electroosmotic pump can be changed instantly. In addition, electroosmotic pumps have no moving parts. In this article, we discuss common features, introduce fabrication technologies and highlight applications of electroosmotic pumps. PMID:20047021

  18. Bearing for liquid metal pump

    International Nuclear Information System (INIS)

    Dickinson, R.J.; Pennell, W.E.; Wasko, J.

    1984-01-01

    A liquid metal pump bearing support comprises a series of tangentially oriented spokes that connect the bearing cylinder to the pump internals structure. The spokes may be arranged in a plurality of planes extending from the bearing cylinder to the pump internals with the spokes in one plane being arranged alternately with those in the next plane. The bearing support structure provides the pump with sufficient lateral support for the bearing structure together with the capability of accommodating differential thermal expansion without adversely affecting pump performance

  19. Tolerance to continuous intrathecal baclofen infusion can be reversed by pulsatile bolus infusion

    NARCIS (Netherlands)

    Heetla, H. W.; Staal, M. J.; van Laar, T.

    Study design: Pilot study. Objective: To study the effect of pulsatile bolus infusion of intrathecal baclofen (ITB) on daily ITB dose, in patients showing dose increases, probably due to tolerance. Setting: Department of neurology and neurosurgery, University Medical Center Groningen, the

  20. Thermo-electric pump

    International Nuclear Information System (INIS)

    Georges, J.-L.; Veyret, J.-F.

    1973-01-01

    Description is given of a thermo-pump for electrically conductive liquid fluids, e.g. for a liquid metal such as sodium. This pump is characterized in that the piping for the circulation of the conductive liquid is constituted by a plurality of conduits defined by two co-axial cylinders and two walls parallel to their axis. Each conduit limited outside by a magnet, inside by a mild-iron tube, and laterally by two materials forming a thermocouple. The electric current generated by that thermo-couple and the magnetic flux generated by the magnets both loop the loop through an outer cylindrical nickel shell. This can be applied to sodium circulation loops for testing nuclear fuel elements [fr

  1. Heat pumps: heat recovery

    Energy Technology Data Exchange (ETDEWEB)

    Pielke, R

    1976-01-01

    The author firstly explains in a general manner the functioning of the heat pump. Following a brief look at the future heat demand and the possibilities of covering it, the various methods of obtaining energy (making use of solar energy, ground heat, and others) and the practical applications (office heating, swimming pool heating etc.) are explained. The author still sees considerable difficulties in using the heat pump at present on a large scale. Firstly there is not enough maintenance personnel available, secondly the electricity supply undertakings cannot provide the necessary electricity on a wide basis without considerable investments. Other possibilities to save energy or to use waste energy are at present easier and more economical to realize. Recuperative and regenerative systems are described.

  2. Water displacement mercury pump

    Science.gov (United States)

    Nielsen, M.G.

    1984-04-20

    A water displacement mercury pump has a fluid inlet conduit and diffuser, a valve, a pressure cannister, and a fluid outlet conduit. The valve has a valve head which seats in an opening in the cannister. The entire assembly is readily insertable into a process vessel which produces mercury as a product. As the mercury settles, it flows into the opening in the cannister displacing lighter material. When the valve is in a closed position, the pressure cannister is sealed except for the fluid inlet conduit and the fluid outlet conduit. Introduction of a lighter fluid into the cannister will act to displace a heavier fluid from the cannister via the fluid outlet conduit. The entire pump assembly penetrates only a top wall of the process vessel, and not the sides or the bottom wall of the process vessel. This insures a leak-proof environment and is especially suitable for processing of hazardous materials.

  3. Pocket pumped image analysis

    Energy Technology Data Exchange (ETDEWEB)

    Kotov, I.V., E-mail: kotov@bnl.gov [Brookhaven National Laboratory, Upton, NY 11973 (United States); O' Connor, P. [Brookhaven National Laboratory, Upton, NY 11973 (United States); Murray, N. [Centre for Electronic Imaging, Open University, Milton Keynes, MK7 6AA (United Kingdom)

    2015-07-01

    The pocket pumping technique is used to detect small electron trap sites. These traps, if present, degrade CCD charge transfer efficiency. To reveal traps in the active area, a CCD is illuminated with a flat field and, before image is read out, accumulated charges are moved back and forth number of times in parallel direction. As charges are moved over a trap, an electron is removed from the original pocket and re-emitted in the following pocket. As process repeats one pocket gets depleted and the neighboring pocket gets excess of charges. As a result a “dipole” signal appears on the otherwise flat background level. The amplitude of the dipole signal depends on the trap pumping efficiency. This paper is focused on trap identification technique and particularly on new methods developed for this purpose. The sensor with bad segments was deliberately chosen for algorithms development and to demonstrate sensitivity and power of new methods in uncovering sensor defects.

  4. FTU pump limiter

    International Nuclear Information System (INIS)

    Alessandrini, C.; Ciotti, M.; Mattei, A. De; Maddaluno, G.; Mazzitelli, G.

    1989-01-01

    The control of the refuelling and recycling of the plasma is crucial in providing enhanced performances in tokamaks and steady-state operation in future reactors. In this paper, we report details of the design and analysis for the pump limiter to be incorporated into the FTU tokamak. The FTU, presently under commissioning, is a compact high field (B=8T), medium high density, circular cross section machine with small accesses. The dimensions of the equatorial port (width 8 cm) would reduce the length of the entrance throat to a few centimeters, which is unacceptable for efficient particle trapping. We have, therefore, designed a rotating blade of the pump limiter head that, in the working position, extends in the toroidal direction inside the vacuum chamber. (author) 8 refs., 4 figs

  5. Geothermal heat pump

    International Nuclear Information System (INIS)

    Bruno, R.; Tinti, F.

    2009-01-01

    In recent years, for several types of buildings and users, the choice of conditioning by heat pump and low enthalpy geothermal reservoir has been increasing in the Italian market. In fact, such systems are efficient in terms of energy and consumption, they can perform, even at the same time, both functions, heating and cooling and they are environmentally friendly, because they do not produce local emissions. This article will introduce the technology and will focus on critical points of a geothermal field design, from actual practice, to future perspectives for the geo exchanger improvement. Finally, the article presents a best practice case in Bologna district, with an economic analysis showing the convenience of a geothermal heat pump. Conclusions of the real benefits of these plants can be drawn: compared to a non-negligible initial cost, the investment has a pay-back period almost always acceptable, usually less than 10 years. [it

  6. 14 CFR 23.991 - Fuel pumps.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Fuel pumps. 23.991 Section 23.991... § 23.991 Fuel pumps. (a) Main pumps. For main pumps, the following apply: (1) For reciprocating engine installations having fuel pumps to supply fuel to the engine, at least one pump for each engine must be directly...

  7. VOLUMETRIC LEAK DETECTION IN LARGE UNDERGROUND STORAGE TANKS - VOLUME I

    Science.gov (United States)

    A set of experiments was conducted to determine whether volumetric leak detection system presently used to test underground storage tanks (USTs) up to 38,000 L (10,000 gal) in capacity could meet EPA's regulatory standards for tank tightness and automatic tank gauging systems whe...

  8. Tandem Gravimetric and Volumetric Apparatus for Methane Sorption Measurements

    Science.gov (United States)

    Burress, Jacob; Bethea, Donald

    Concerns about global climate change have driven the search for alternative fuels. Natural gas (NG, methane) is a cleaner fuel than gasoline and abundantly available due to hydraulic fracturing. One hurdle to the adoption of NG vehicles is the bulky cylindrical storage vessels needed to store the NG at high pressures (3600 psi, 250 bar). The adsorption of methane in microporous materials can store large amounts of methane at low enough pressures for the allowance of conformable, ``flat'' pressure vessels. The measurement of the amount of gas stored in sorbent materials is typically done by measuring pressure differences (volumetric, manometric) or masses (gravimetric). Volumetric instruments of the Sievert type have uncertainties that compound with each additional measurement. Therefore, the highest-pressure measurement has the largest uncertainty. Gravimetric instruments don't have that drawback, but can have issues with buoyancy corrections. An instrument will be presented with which methane adsorption measurements can be performed using both volumetric and gravimetric methods in tandem. The gravimetric method presented has no buoyancy corrections and low uncertainty. Therefore, the gravimetric measurements can be performed throughout an entire isotherm or just at the extrema to verify the results from the volumetric measurements. Results from methane sorption measurements on an activated carbon (MSC-30) and a metal-organic framework (Cu-BTC, HKUST-1, MOF-199) will be shown. New recommendations for calculations of gas uptake and uncertainty measurements will be discussed.

  9. 100KE/KW fuel storage basin surface volumetric factors

    International Nuclear Information System (INIS)

    Conn, K.R.

    1996-01-01

    This Supporting Document presents calculations of surface Volumetric factors for the 100KE and 100KW Fuel Storage Basins. These factors relate water level changes to basin loss or additions of water, or the equivalent water displacement volumes of objects added to or removed from the basin

  10. Designing remote web-based mechanical-volumetric flow meter ...

    African Journals Online (AJOL)

    Today, in water and wastewater industry a lot of mechanical-volumetric flow meters are used for the navigation of the produced water and the data of these flow meters, due to use in a wide geographical range, is done physically and by in person presence. All this makes reading the data costly and, in some cases, due to ...

  11. Nonazeotropic Heat Pump

    Science.gov (United States)

    Ealker, David H.; Deming, Glenn

    1991-01-01

    Heat pump collects heat from water circulating in heat-rejection loop, raises temperature of collected heat, and transfers collected heat to water in separate pipe. Includes sealed motor/compressor with cooling coils, evaporator, and condenser, all mounted in outer housing. Gradients of temperature in evaporator and condenser increase heat-transfer efficiency of vapor-compression cycle. Intended to recover relatively-low-temperature waste heat and use it to make hot water.

  12. IRRIGATION USING SOLAR PUMP

    OpenAIRE

    Prof. Nitin P.Choudhary*1 & Ms. Komal Singne2

    2017-01-01

    In this report the described design of a PV and soil moisture sensor based automated irrigation system is introduced. This project aims to provide a human friendly, economical and automated water pumping system which eliminates the problems of over irrigation and helps in irrigation water optimization and manage it in accordance with the availability of water. Our project not only tries to modernize the irrigation practices and ensure the optimum yield by carefully fulfilling the requirements...

  13. Small size ion pumps

    International Nuclear Information System (INIS)

    Cyranski, R.; Kiliszek, Cz.R.; Marks, J.; Sobolewski, A.; Magielko, H.

    2001-01-01

    This paper describes some designs of the two versions ion pumps and their range operation for various magnetic fields. The first version is made with different cell size in the anode element and titanium cathode operating in magnetic field from 600 to 650 Gs and the second version with the same anode element but differential Ti/Ta cathode working in magnetic field above 1200 Gs

  14. Pumping potential wells

    Science.gov (United States)

    Hershkowitz, N.; Forest, C.; Wang, E. Y.; Intrator, T.

    1987-01-01

    Nonmonotonic plasma potential structures are a common feature of many double layers and sheaths. Steady state plasma potential wells separating regions having different plasma potentials are often found in laboratory experiments. In order to exist, such structures all must find a solution to a common problem. Ions created by charge exchange or ionization in the region of the potential well are electrostatically confined and tend to accumulate and fill up the potential well. The increase in positive charge should eliminate the well. Nevertheless, steady state structures are found in which the wells do not fill up. This means that it is important to take into account processes which 'pump' ions from the well. As examples of ion pumping of plasma wells, potential dips in front of a positively biased electro collecting anode in a relatively cold, low density multidipole plasma is considered. Pumping is provided by ion leaks from the edges of the potential dip or by oscillating the applied potential. In the former case the two dimensional character of the problem is shown to be important.

  15. Pumping potential wells

    International Nuclear Information System (INIS)

    Hershkowitz, N.; Forest, C.; Wang, E.Y.; Intrator, T.

    1987-01-01

    Nonmonotonic plasma potential structures are a common feature of many double layers and sheaths. Steady state plasma potential wells separating regions having different plasma potentials are often found in laboratory experiments. In order to exist, all such structures must find a solution to a common problem. Ions created by charge exchange or ionization in the region of the potential well are electrostatically confined and tend to accumulate and fill up the potential well. The increase in positive charge should eliminate the well. Nevertheless, steady state structures are found in which the wells do not fill up. This means that it is important to take into account processes which pump ions from the well. As examples of ion pumping of plasma wells, potential dips in front of a positively biased electron collecting anode in a relatively cold, low density, multidipole plasma are considered. Pumping is provided by ion leaks from the edges of the potential dip or by oscillating the applied potential. In the former case the two-dimensional character of the problem is shown to be important

  16. Pumping potential wells

    International Nuclear Information System (INIS)

    Hershkowitz, N.; Forest, C.; Wang, E.Y.; Intrator, T.

    1987-01-01

    Nonmonotonic plasma potential structures are a common feature of many double layers and sheaths. Steady state plasma potential wells separating regions having different plasma potentials are often found in laboratory experiments. In order to exist, such structures all must find a solution to a common problem. Ions created by charge exchange or ionization in the region of the potential well are electrostatically confined and tend to accumulate and fill up the potential well. The increase in positive charge should eliminate the well, but steady state structures are found in which the wells do not fill up. This means that it is important to take into account processes which 'pump' ions from the well. As examples of ion pumping of plasma wells, potential dips in front of a positively biased electron collecting anode in a relatively cold, low density multidipole plasma are considered. Pumping is provided by ion leaks from the edges of the potential dip or by oscillating the applied potential. In the former case the two dimensional character of the problem is shown to be important. (author)

  17. Jet operated heat pump

    International Nuclear Information System (INIS)

    Collard, T.H.

    1982-01-01

    A jet pump system is shown that utilizes waste heat to provide heating and/or cooling. Waste heat diverted through a boiler causes a refrigerant to evaporate and expand for supersonic discharge through a nozzle thereby creating a vacuum in an evaporator coil. The vacuum draws the refrigerant in a gaseous state into a condensing section of a jet pump along with refrigerant from a reservoir in a subcooled liquid form. This causes condensation of the gas in a condensation section of the jet pump, while moving at constant velocity. The change in momentum of the fluid overcomes the system high side pressure. Some of the condensate is cooled by a subcooler. Refrigerant in a subcooled liquid state from the subcooler is fed back into the evaporator and the condensing section with an adequate supply being insured by the reservoir. The motive portion of the condensate is returned to the boiler sans subcooling. By proper valving start-up is insured, as well as the ability to switch from heating to cooling

  18. Controlling groundwater pumping online.

    Science.gov (United States)

    Zekri, Slim

    2009-08-01

    Groundwater over-pumping is a major problem in several countries around the globe. Since controlling groundwater pumping through water flow meters is hardly feasible, the surrogate is to control electricity usage. This paper presents a framework to restrict groundwater pumping by implementing an annual individual electricity quota without interfering with the electricity pricing policy. The system could be monitored online through prepaid electricity meters. This provides low transaction costs of individual monitoring of users compared to the prohibitive costs of water flow metering and monitoring. The public groundwater managers' intervention is thus required to determine the water and electricity quota and watch the electricity use online. The proposed framework opens the door to the establishment of formal groundwater markets among users at very low transaction costs. A cost-benefit analysis over a 25-year period is used to evaluate the cost of non-action and compare it to the prepaid electricity quota framework in the Batinah coastal area of Oman. Results show that the damage cost to the community, if no active policy is implemented, amounts to (-$288) million. On the other hand, the implementation of a prepaid electricity quota with an online management system would result in a net present benefit of $199 million.

  19. Liquid sodium pumps

    International Nuclear Information System (INIS)

    Allen, H.G.

    1985-01-01

    The pump for use in a nuclear reactor cooling system comprises a booster stage impeller for drawing the liquid through the inlet. A diffuser is affixedly disposed within the pump housing to convert the kinetic pressure imparted to the liquid into increased static pressure. A main stage impeller is rotatively driven by a pump motor at a relatively high speed to impart a relatively high static pressure to the liquid and for discharging the liquid at a relatively high static pressure. A hydraulic coupling is disposed remotely from the liquid path for hydraulically coupling the main stage impeller and the booster stage impeller to rotate the booster stage impeller at a relatively low speed to maintain the low net positive suction pressure applied to the liquid at the inlet greater than the vapor pressure of the liquid and to ensure that the low net positive suction heat, as established by the main stage impeller exceeds the vapor pressure. The coupling comprises a grooved drum which rotates between inner and outer drag coupling members. In a modification the coupling comprises a torque converter. (author)

  20. Electrocentrifugal pumping; Bombeo electrocentrifugo

    Energy Technology Data Exchange (ETDEWEB)

    Rodriguez Perez, Guillermo; Medellin Otero, Hector [Instituto Mexicano del Peroleo (Mexico)

    1996-07-01

    The exploitation of isolated oil deposits, in losing their own energy, enter a phase of secondary recovery. One of the technologies of new development in Mexico is the one of electrocentrifugal pumping , which consists of introducing the motor-pump as an integral part of the production pipe down to the well bottom and pumping directly up to central complexes, from where it is sent inland. In the present paper is intended to explain what this type of secondary recovery consists of. [Spanish] La explotacion de yacimientos aislados de petroleo, al perder su energia propia, entran en una fase de recuperacion secundaria. Una de las tecnologias de nuevo desarrollo en Mexico es la de bombeo electrocentrifugo, la cual consiste en introducir la motobomba como parte integral de la tuberia de produccion hasta el fondo del pozo y bombearlo directamente hasta los complejos centrales, de donde se envia a tierra. En el presente trabajo se pretende explicar en que consiste este tipo de recuperacion secundaria.

  1. Optically pumped terahertz sources

    Institute of Scientific and Technical Information of China (English)

    ZHONG Kai; SHI Wei; XU DeGang; LIU PengXiang; WANG YuYe; MEI JiaLin; YAN Chao; FU ShiJie; YAO JianQuan

    2017-01-01

    High-power terahertz (THz) generation in the frequency range of0.1-10 THz has been a fast-developing research area ever since the beginning of the THz boom two decades ago,enabling new technological breakthroughs in spectroscopy,communication,imaging,etc.By using optical (laser) pumping methods with near-or mid-infrared (IR) lasers,flexible and practical THz sources covering the whole THz range can be realized to overcome the shortage of electronic THz sources and now they are playing important roles in THz science and technology.This paper overviews various optically pumped THz sources,including femtosecond laser based ultrafast broadband THz generation,monochromatic widely tunable THz generation,single-mode on-chip THz source from photomixing,and the traditional powerful THz gas lasers.Full descriptions from basic principles to the latest progress are presented and their advantages and disadvantages are discussed as well.It is expected that this review gives a comprehensive reference to researchers in this area and additionally helps newcomers to quickly gain understanding of optically pumped THz sources.

  2. Swelling and infusion of tea in tea bags.

    Science.gov (United States)

    Yadav, Geeta U; Joshi, Bhushan S; Patwardhan, Ashwin W; Singh, Gurmeet

    2017-07-01

    The present study deals with swelling and infusion kinetics of tea granules in tea bags. The swelling and infusion kinetics of tea bags differing in tea loading and tea bag shapes were compared with loose tea. Increment in temperature and dipping frequency of tea bag in hot water increased the infusion kinetics of tea bags. Reduction in particle size enhanced the swelling and infusion kinetics of tea in a tea bag. The effects of tea particle size, tea bag dipping rate, loading of tea granules in tea bag and tea bag shapes on infusion kinetics were investigated. Increase in tea loading in tea bags resulted in reduced infusion kinetics. Double chambered tea bag showed the highest swelling (30%) and infusion kinetics (8.30% Gallic acid equivalence) while single chambered tea bags showed the lowest kinetics, amongst the various bags studied. The swelling and infusion kinetics of loose tea was always faster and higher than that of tea bags. It was found that overall effect of percentage filling of tea granules and height of tea bed in a tea bag affects tea infusion kinetics the most. Weibull model was found to be in good agreement with the swelling data.

  3. Clinical applications of continuous infusion chemotherapy ahd concomitant radiation therapy

    International Nuclear Information System (INIS)

    Rosenthal, C.J.; Rotman, M.

    1986-01-01

    This book presents information on the following topics: theoretical basis and clinical applications of 5-FU as a radiosensitizer; treatment of hepatic metastases from gastro intestingal primaries with split course radiation therapy; combined modality therapy with 5-FU, Mitomycin-C and radiation therapy for sqamous cell cancers; treatment of bladder carcinoma with concomitant infusion chemotherapy and irradiation; a treatment of invasiv bladder cancer by the XRT/5FU protocol; concomitant radiation therapy and doxorubicin by continuous infusion in advanced malignancies; cis platin by continuous infusion with concurrent radiation therapy in malignant tumors; combination of radiation with concomitant continuous adriamycin infusion in a patient with partially excised pleomorphic soft tissue sarcoma of the lower extremeity; treatment of recurrent carcinoma of the paranasal sinuses using concomitant infusion cis-platinum and radiation therapy; hepatic artery infusion for hepatic metastases in combination with hepatic resection and hepatic radiation; study of simultaneous radiation therapy, continuous infusion, 5FU and bolus mitomycin-C; cancer of the esophagus; continuous infusion VP-16, bolus cis-platinum and simultaneous radiation therapy as salvage therapy in small cell bronchogenic carcinoma; and concomitant radiation, mitomycin-C and 5-FU infusion in gastro intestinal cancer

  4. In-use Stability of Ceftaroline Fosamil in Elastomeric Home Infusion Systems and MINI-BAG Plus Containers.

    Science.gov (United States)

    Bhattacharya, Sisir; Parekh, Satish; Dedhiya, Mahendra

    2015-01-01

    The objective of this study was to determine in-use stability of ceftaroline fosamil infusion solution of concentrations up to 12 mg/mL in elastomeric home infusion system prefilled with 0.9% Sodium Chloride Injection USP or 5% Dextrose Injection USP and MINI-BAG Plus Container delivery devices prefilled with 0.9% sodium chloride injection. In-use ceftaroline fosamil infusion solution (12 mg/mL) was prepared for elastomeric home infusion systems (Homepump Eclipse, Baxter Intermate, and AccuRx Elastomeric Pump) pre-filled with either 0.9% sodium chloride injection or 5% dextrose; or Baxter MINI-BAG Plus Containers pre-filled with 0.9% Sodium Chloride Injection USP (4 mg/mL to 12 mg/mL ceftaroline fosamil in final solution). The systems were stored refrigerated for 24 hours followed by up to 6 hours of storage at room temperature. Samples were analyzed at various time points for assay and degradation product by a validated stability-indicating high-performance liquid chromatography method. In-use ceftaroline fosamil infusion solution, ranging from 4-mg/mL to a maximum of 12-mg/mL concentration, in elastomeric home infusion systems prefilled with 0.9% sodium chloride injection or 5% dextrose, and MINI-BAG Plus Containers prefilled with 0.9% sodium chloride injection were chemically stable for up to 24 hours refrigerated at 2°C to 8°C (36°F to 46°F) and up to 6 hours at room temperature and had acceptable compatibility with material used. Ceftaroline fosamil (4 mg/mL to 12 mg/mL) maintains its potency for up to 24 hours refrigerated at 2°C to 8°C (36°F to 46°F) and up to 6 hours of storage at room temperature upon reconstitution in infusion solution with 0.9% sodium chloride or 5% dextrose when used in elastomeric home infusion system and MINI-BAG Plus Containers delivery devices prefilled with 0.9% sodium chloride injection.

  5. Comparative Study of the Volumetric Methods Calculation Using GNSS Measurements

    Science.gov (United States)

    Şmuleac, Adrian; Nemeş, Iacob; Alina Creţan, Ioana; Sorina Nemeş, Nicoleta; Şmuleac, Laura

    2017-10-01

    This paper aims to achieve volumetric calculations for different mineral aggregates using different methods of analysis and also comparison of results. To achieve these comparative studies and presentation were chosen two software licensed, namely TopoLT 11.2 and Surfer 13. TopoLT program is a program dedicated to the development of topographic and cadastral plans. 3D terrain model, level courves and calculation of cut and fill volumes, including georeferencing of images. The program Surfer 13 is produced by Golden Software, in 1983 and is active mainly used in various fields such as agriculture, construction, geophysical, geotechnical engineering, GIS, water resources and others. It is also able to achieve GRID terrain model, to achieve the density maps using the method of isolines, volumetric calculations, 3D maps. Also, it can read different file types, including SHP, DXF and XLSX. In these paper it is presented a comparison in terms of achieving volumetric calculations using TopoLT program by two methods: a method where we choose a 3D model both for surface as well as below the top surface and a 3D model in which we choose a 3D terrain model for the bottom surface and another 3D model for the top surface. The comparison of the two variants will be made with data obtained from the realization of volumetric calculations with the program Surfer 13 generating GRID terrain model. The topographical measurements were performed with equipment from Leica GPS 1200 Series. Measurements were made using Romanian position determination system - ROMPOS which ensures accurate positioning of reference and coordinates ETRS through the National Network of GNSS Permanent Stations. GPS data processing was performed with the program Leica Geo Combined Office. For the volumetric calculating the GPS used point are in 1970 stereographic projection system and for the altitude the reference is 1975 the Black Sea projection system.

  6. Visualization and computer graphics on isotropically emissive volumetric displays.

    Science.gov (United States)

    Mora, Benjamin; Maciejewski, Ross; Chen, Min; Ebert, David S

    2009-01-01

    The availability of commodity volumetric displays provides ordinary users with a new means of visualizing 3D data. Many of these displays are in the class of isotropically emissive light devices, which are designed to directly illuminate voxels in a 3D frame buffer, producing X-ray-like visualizations. While this technology can offer intuitive insight into a 3D object, the visualizations are perceptually different from what a computer graphics or visualization system would render on a 2D screen. This paper formalizes rendering on isotropically emissive displays and introduces a novel technique that emulates traditional rendering effects on isotropically emissive volumetric displays, delivering results that are much closer to what is traditionally rendered on regular 2D screens. Such a technique can significantly broaden the capability and usage of isotropically emissive volumetric displays. Our method takes a 3D dataset or object as the input, creates an intermediate light field, and outputs a special 3D volume dataset called a lumi-volume. This lumi-volume encodes approximated rendering effects in a form suitable for display with accumulative integrals along unobtrusive rays. When a lumi-volume is fed directly into an isotropically emissive volumetric display, it creates a 3D visualization with surface shading effects that are familiar to the users. The key to this technique is an algorithm for creating a 3D lumi-volume from a 4D light field. In this paper, we discuss a number of technical issues, including transparency effects due to the dimension reduction and sampling rates for light fields and lumi-volumes. We show the effectiveness and usability of this technique with a selection of experimental results captured from an isotropically emissive volumetric display, and we demonstrate its potential capability and scalability with computer-simulated high-resolution results.

  7. Feasibility of saline infusion on the liver surface during radiofrequency ablation of subcapsuIar hepatic tumor: an experimentaI study

    International Nuclear Information System (INIS)

    Lee, Young Rang; Kim, Young Sun; Rhim, Hyun Chul; Seo, Heung Suk; Cho, On Koo; Koh, Byung Hee; Kim, Yong Soo; Kim, Sung Kyu; Paik, Seung Sam

    2004-01-01

    The purpose of the study was to evaluate the feasibility of infusion of normal saline onto the surface of the liver capsule for minimizing thermal injury of the adjacent organs during radiofrequency ablation of subcapsular hepatic tumor in an ex-vivo porcine model. We used porcine small bowel with it's serosal surface spread onto the porcine liver as an experiment model. The puncturing electrode was inserted into a 6 Fr introducer sheath, and the introducer sheath was connected to the infusion pump for creating a saline flow over the liver surface. A total of 15 ablations were divided into the control group (n=5), intermittent saline infusion group (n=5) and continuous saline infusion (n=5) group. The ablations were done during 3 minutes, and the infusion was set at 2 ml/min and stopped every 30 seconds in the intermittent saline infusion group. After the ablation, we measured the size of the ablated lesion on the surface of bowel and liver, and we also measured the depth of hepatic lesion. Ablated areas of bowel and liver surface in the control group, intermittent saline infusion group and continuous infusion group were 210.7±89.1 mm 2 , 74.6±27.2 mm 2 and 35.8±43.4 mm 2 , respectively, and 312.6±73.6 mm 2 , 228.4±110.5 mm 2 , and 80.9±55.1 mm 2 , respectively. In contrast to the broad base of the ablated area on the surface of the liver in the control group, the shapes of the lesions became narrower approaching to the liver surface in all cases of the continuous saline infusion group, and the shapes of the lesions were broad based in 3 cases and narrow based in 2 cases of the intermittent saline infusion group. Continuous infusion of normaI saline onto the surface of the liver during radiofrequency ablation of subcapsular hepatic tumor is a feasible method for minimizing thermal injury of the adjacent organs. Further exploration of the optimal parameters or techniques to maximize the hepatic ablation and simultaneously to minimize the thermal injury of

  8. Supercritical waste oxidation pump investigation

    International Nuclear Information System (INIS)

    Thurston, G.; Garcia, K.

    1993-02-01

    This report investigates the pumping techniques and pumping equipment that would be appropriate for a 5,000 gallon per day supercritical water oxidation waste disposal facility. The pumps must boost water, waste, and additives from atmospheric pressure to approximately 27.6 MPa (4,000 psia). The required flow ranges from 10 gpm to less than 0.1 gpm. For the higher flows, many commercial piston pumps are available. These pumps have packing and check-valves that will require periodic maintenance; probably at 2 to 6 month intervals. Several commercial diaphragm pumps were also discovered that could pump the higher flow rates. Diaphragm pumps have the advantage of not requiring dynamic seals. For the lower flows associated with the waste and additive materials, commercial diaphragm pumps. are available. Difficult to pump materials that are sticky, radioactive, or contain solids, could be injected with an accumulator using an inert gas as the driving mechanism. The information presented in this report serves as a spring board for trade studies and the development of equipment specifications

  9. Is continuous infusion of imipenem always the best choice?

    Science.gov (United States)

    Suchánková, Hana; Lipš, Michal; Urbánek, Karel; Neely, Michael N; Strojil, Jan

    2017-03-01

    Monte Carlo simulations allow prediction and comparison of concentration-time profiles arising from different dosing regimens in a defined population, provided a population pharmacokinetic model has been established. The aims of this study were to evaluate the population pharmacokinetics of imipenem in critically ill patients with hospital-acquired pneumonia (HAP) and to assess the probability of target attainment (PTA) and cumulative fraction of response (CFR) using EUCAST data. A two-compartment model based on a data set of 19 subjects was employed. Various dosage regimens at 0.5-h and 3-h infusion rates and as continuous infusion were evaluated against the pharmacodynamic targets of 20%fT >MIC , 40%fT >MIC and 100%fT >MIC . For the target of 40%fT >MIC , all 0.5-h infusion regimens achieved optimal exposures (CFR ≥ 90%) against Escherichia coli and Staphylococcus aureus, with nearly optimal exposure against Klebsiella pneumoniae (CFR ≥ 89.4%). The 3-h infusions and continuous infusion exceeded 97% CFR against all pathogens with the exception of Pseudomonas aeruginosa and Acinetobacter spp., where the maximum CFRs were 85.5% and 88.4%, respectively. For the 100%fT >MIC target, only continuous infusion was associated with nearly optimal exposures. Higher PTAs for the targets of 40%fT >MIC and 100%fT >MIC were achieved with 3-h infusions and continuous infusion in comparison with 0.5-h infusions; however, continuous infusion carries a risk of not reaching the MIC of less susceptible pathogens in a higher proportion of patients. In critically ill patients with HAP with risk factors for Gram-negative non-fermenting bacteria, maximum doses administered as extended infusions may be necessary. Copyright © 2017 Elsevier B.V. and International Society of Chemotherapy. All rights reserved.

  10. Experimental Study on Series Operation of Sliding Vane Pump and Centrifugal Pump

    OpenAIRE

    Li, Tao; Zhang, Weiming; Jiang, Ming; Li, Zhengyang

    2013-01-01

    A platform for sliding vane pump and centrifugal pump tests is installed to study the series operation of them under different characteristics of pipeline. Firstly, the sliding vane pump and the centrifugal pump work independently, and the performance is recorded. Then, the two types of pumps are combined together, with the sliding vane pump acting as the feeding pump. Comparison is made between the performance of the independently working pump and the performance of series operation pump. Re...

  11. Smart pumps and random safety audits in a Neonatal Intensive Care Unit: a new challenge for patient safety.

    Science.gov (United States)

    Bergon-Sendin, Elena; Perez-Grande, Carmen; Lora-Pablos, David; Moral-Pumarega, María Teresa; Melgar-Bonis, Ana; Peña-Peloche, Carmen; Diezma-Rodino, Mercedes; García-San Jose, Lidia; Cabañes-Alonso, Esther; Pallas-Alonso, Carmen Rosa

    2015-12-11

    Random safety audits (RSA) are a safety tool enabling prevention of adverse events, but they have not been widely used in hospitals. The aim of this study was to use RSAs to assess and compare the frequency of appropriate use of infusion pump safety systems in a Neonatal Intensive Care Unit (NICU) before and after quality improvement interventions and to analyse the intravenous medication programming data. Prospective, observational study comparing the frequency of appropriate use of Alaris® CC smart pumps through RSAs over two periods, from 1 January to 31 December 2012 and from 1 November 2014 to 31 January 2015. Appropriate use was defined as all evaluated variables being correctly programmed into the same device. Between the two periods they were established interventions to improve the use of pumps. The information recorded at the pumps with the new security system, also extracted for one year. Fifty-two measurements were collected during the first period and 160 measurements during the second period. The frequency of appropriate use was 73.13 % (117/160) in the second period versus 0 % (0/52) in the first period (p pumps in the NICU. The improvement strategies were effective for improving appropriate use and programming of the intravenous medication infusion pumps in our NICU.

  12. Diode laser pumping

    International Nuclear Information System (INIS)

    Skagerlund, L.E.

    1975-01-01

    A diode laser is pumped or pulsed by a repeated capacitive discharge. A capacitor is periodically charged from a dc voltage source via a transformer, the capacitor being discharged through the diode laser via a controlled switching means after one or more charging periods. During a first interval of each charging period the transformer, while unloaded, stores a specific amount of energy supplied from the dc voltage source. During a subsequent interval of the charging period said specific amount of energy is transmitted from the transformer to the capacitor. The discharging of the capacitor takes place during a first interval of a charging period. (auth)

  13. Novel limiter pump topologies

    International Nuclear Information System (INIS)

    Schultz, J.H.

    1981-01-01

    The use of limiter pumps as the principle plasma exhaust system of a magnetic confinement fusion device promises significant simplification, when compared to previously investigating divertor based systems. Further simplifications, such as the integration of the exhaust system with a radio frequency heating system and with the main reactor shield and structure are investigated below. The integrity of limiters in a reactor environment is threatened by many mechanisms, the most severe of which may be erosion by sputtering. Two novel topolgies are suggested which allow high erosion without limiter failure

  14. Novel limiter pump topologies

    International Nuclear Information System (INIS)

    Schultz, J.H.

    1981-01-01

    The use of limiter pumps as the principle plasma exhaust system of a magnetic confinement fusion device promises significant simplification, when compared to previously investigating divertor based systems. Further simplifications, such as the integration of the exhaust system with a radio frequency heating system and with the main reactor shield and structure are investigated below. The integrity of limiters in a reactor environment is threatened by many mechanisms, the most severe of which may be erosion by sputtering. Two novel topologies are suggested which allow high erosion without limiter failure

  15. Improvements relating to electromagnetic pumps

    International Nuclear Information System (INIS)

    Davidson, D.F.

    1975-01-01

    Reference is made to electromagnetic pumps suitable for use in pumping molten Na, and particularly to annular linear induction pumps that may for example be used to pump molten Na at temperatures up to 650 0 in situations where it is not possible to provide cooling. Previous designs of such pumps have employed disk-shaped coils around the outside of the annulus, the coils being energised from a three-phase power supply to produce a travelling radial field. The pump system described obviates the necessity for joints between the coils. It also allows the use of all types of high temperature insultation, simplified manufacture, and enables the windings to be located on the inside of the annulus. Full constructional details are given. (U.K.)

  16. Fast breeder reactor electromagnetic pump

    International Nuclear Information System (INIS)

    Araseki, Hideo; Murakami, Takahiro

    2008-01-01

    Main pumps circulating sodium in the FBR type reactor have been mechanical types, not electromagnetic pumps. Electromagnetic pump of 1-2 m 3 /min has been used as an auxiliary pump. Large sized electromagnetic pumps such as several hundred m 3 /min have not been commercialized due to technical difficulties with electromagnetic instability and pressure pulsations. This article explained electromagnetic and fluid equations and magnetic Reynolds number related with electromagnetic pumps and numerical analysis of instability characteristics and pressure pulsations and then described applications of the results to FBR system. Magnetic Reynolds number must be chosen less than one with appropriate operating frequency and optimum slip of 0.2-0.4. (T. Tanaka)

  17. Mechanical pumping at low temperature

    Energy Technology Data Exchange (ETDEWEB)

    Perin, J.P.; Claudet, G.; Disdier, F.

    1994-12-31

    This new concept consists of a mechanical pump able to run at low temperature (25 K). Since gas density varies inversely with temperature, the pump could deliver much higher mass flow rate than at room temperature for a given size. Advantages of this concept are reduction of an order of magnitude in size and weight when compared to a conventional pump scaled to perform the same mass flow rate at room temperature. Results obtained at 80 K and 25 K with a Holweck type molecular drag pump of 100 mm diameter and with few stages of a turbomolecular pump running at the same temperatures, are given. This pump would be a solution to allow continuous tritium extraction and minimize the mass inventory for the ITER (International Tokamak Experiment Reactor). 5 figs., 2 tabs., 4 refs.

  18. Inhibition of endogenous lactate turnover with lactate infusion in humans

    International Nuclear Information System (INIS)

    Searle, G.L.; Feingold, K.R.; Hsu, F.S.; Clark, O.H.; Gertz, E.W.; Stanley, W.C.

    1989-01-01

    The extent to which lactate infusion may inhibit endogenous lactate production, though previously considered, has never been critically assessed. To examine this proposition, single injection tracer methodology (U- 14 C Lactate) has been used for the estimation of lactate kinetics in 12 human subjects under basal conditions and with the infusion of sodium lactate. The basal rate of lactate turnover was measured on a day before the study with lactate infusion, and averaged 63.7 + 5.5 mg/kg/h. Six of these individuals received a stable lactate infusion at an approximate rate of 160 mg/kg/h, while the remaining six individuals were infused at the approximate rate of 100 mg/kg/h. It has been found that stable lactate infused at rates approximating 160 mg/kg/h consistently produced a complete inhibition of endogenous lactate production. Infusion of lactate at 100 mg/kg/h caused a lesser and more variable inhibition of endogenous lactate production (12% to 64%). In conclusion, lactate infusion significantly inhibits endogenous lactate production

  19. Differential effects of insulin injections and insulin infusions on levels ...

    African Journals Online (AJOL)

    Studies have shown that while injections of insulin cause an increase in fat mass, infusions of insulin increase fat mass. The aim of this paper was to test the hypothesis that if an increase in glycogen is an indicator of an impending increase in adipose mass, then insulin infusions should not increase glycogen, while insulin ...

  20. ArtsIN: Arts Integration and Infusion Framework

    Science.gov (United States)

    Hartle, Lynn C.; Pinciotti, Patricia; Gorton, Rebecca L.

    2015-01-01

    Teaching to meet the diverse learning needs of twenty-first century, global learners can be challenging, yet a growing body of research points to the proved successes of arts-infused and integrated curricula, especially for building capacity for learning and motivation. This article presents the ArtsIN: Arts Integration and Infusion framework, a…

  1. Effect of serotonin infusions on the mean plasma concentrations of ...

    African Journals Online (AJOL)

    Milk samples were assayed for protein, fat and lactose constituents. The daily amounts of milk were determined throughout the experiment. Infusions of 1 ng 5HT did not change the plasma concentrations of the T3, T4 and GH throughout the experiment period. Infusions of 4 and 8 ng 5HT significantly (p<0.01) increased the ...

  2. Perisciatic infusion of ropivacaine and analgesia after hallux valgus repair

    DEFF Research Database (Denmark)

    Zaric, D; Jørgensen, B G; Laigaard, F

    2010-01-01

    Moderate to severe pain after hallux valgus repair can be successfully treated with a continuous popliteal sciatic nerve block in ambulatory patients. Different anesthesiologists use various infusion rates for this purpose. The aim of this study was to compare the analgesic efficacy of two infusion...

  3. Haemolytic anaemia as a complication to intravenous immunoglobulin infusion

    DEFF Research Database (Denmark)

    Markvardsen, Lars Høj; Harbo, Thomas; Christiansen, Ingelise

    performed before and two weeks after infusion of IVIg. Following treatment blood haemoglobin declined from 8.6±0.8 to 8.1±1.3mmol/l, p... naive patients are susceptible to develop haemolysis. Haemolytic anaemia is a severe side effect that seems to be more frequent after immunoglobulin infusions than previously recognized....

  4. Effect of perioperative insulin infusion on surgical morbidity and mortality

    DEFF Research Database (Denmark)

    Gandhi, Gunjan Y; Murad, M Hassan; Flynn, Errol David

    2008-01-01

    To conduct a systematic review and meta-analysis of randomized controlled trials (RCTs) to evaluate the effect of perioperative insulin infusion on outcomes important to patients.......To conduct a systematic review and meta-analysis of randomized controlled trials (RCTs) to evaluate the effect of perioperative insulin infusion on outcomes important to patients....

  5. Investigation of ammonia/water hybrid absorption/compression heat pumps for heat supply temperatures above 100 °C

    DEFF Research Database (Denmark)

    Jensen, Jonas Kjær; Reinholdt, Lars; Markussen, Wiebke Brix

    2014-01-01

    The hybrid absorption/compression heat pump (HACHP) using ammonia-water as working fluid is a promising technology for development of a high temperature industrial heat pump. This is due to two properties inherent to the use of zeotropic mixtures: non-isothermal phase change and reduced vapour...... using these components. A technically and economically feasible solution is defined as one that satisfies constraints on the coefficient of performance (COP), low and high pressure, compressor discharge temperature and volumetric heat capacity. The ammonia mass fraction of the rich solution...

  6. Considerations for reference pump curves

    International Nuclear Information System (INIS)

    Stockton, N.B.

    1992-01-01

    This paper examines problems associated with inservice testing (IST) of pumps to assess their hydraulic performance using reference pump curves to establish acceptance criteria. Safety-related pumps at nuclear power plants are tested under the American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel Code (the Code), Section 11. The Code requires testing pumps at specific reference points of differential pressure or flow rate that can be readily duplicated during subsequent tests. There are many cases where test conditions cannot be duplicated. For some pumps, such as service water or component cooling pumps, the flow rate at any time depends on plant conditions and the arrangement of multiple independent and constantly changing loads. System conditions cannot be controlled to duplicate a specific reference value. In these cases, utilities frequently request to use pump curves for comparison of test data for acceptance. There is no prescribed method for developing a pump reference curve. The methods vary and may yield substantially different results. Some results are conservative when compared to the Code requirements; some are not. The errors associated with different curve testing techniques should be understood and controlled within reasonable bounds. Manufacturer's pump curves, in general, are not sufficiently accurate to use as reference pump curves for IST. Testing using reference curves generated with polynomial least squares fits over limited ranges of pump operation, cubic spline interpolation, or cubic spline least squares fits can provide a measure of pump hydraulic performance that is at least as accurate as the Code required method. Regardless of the test method, error can be reduced by using more accurate instruments, by correcting for systematic errors, by increasing the number of data points, and by taking repetitive measurements at each data point

  7. Centrifugal pumps and allied machinery

    CERN Document Server

    Anderson, HH

    1994-01-01

    This book will be of vital interest to all engineers and designers concerned with centrifugal pumps and turbines. Including statistical information derived from 20000 pumps and 700 turbines with capacities of 5gpm to 5000000gpm, this book offers the widest range and scope of information currently available. Statistical analyses suggest practical methods of increasing pump performance and provide valuable data for new design aspects.

  8. Canadian Palliative Community Milrinone Infusions: A Case Series.

    Science.gov (United States)

    Reimche, Ruthanne; Salcedo, Daniel

    2016-01-01

    Abstract Symptom managementfor end-of-life heartfailure (HF) patients is a significant concern. Currently, Canadian practice does not support community milrinone therapy in end-of-life HF patients. Two patients had severe HF that was unresponsive to optimal medications. Further optimization and furosemide infusions were ineffective for symptom management. Both patients' symptoms were better controlled with optimal medication, furosemide, and milrinone infusions. A tailored discharge plan was developed to assist with community milrinone infusions. We discuss the challenges and successes of transitioning two patients to the community. By providing symptom management and meaningful patient and family experience, both patients were able to die in a setting of their choosing. Milrinone infusions as a bridge to end of life may improve symptoms and quality of life. Select patients may benefit from milrinone infusions with resources put in place; these end-of-life HF patients can be supported in the community.

  9. Superselective intraarterial infusion therapy for head and neck carcinomas

    International Nuclear Information System (INIS)

    Nakatani, Hiroaki; Sawada, Shoichi; Takeda, Taizo

    2004-01-01

    We report the results of superselective intraarterial cisplatin (CDDP) infusion therapy combined with irradiation for 23 patients, mainly advanced head and neck carcinoma. All patients received intraarterial CDDP infusions with intravenous sodium thiosulfate (STS) neutralization. CDDP infusion was performed by the Seldinger's technique in 16 patients and by the implanted intraarterial reservoir system in 7 patients. STS was also infused by the reservoir system implanted at the forearm in most patients. An overall response was observed in 21 of the 23 (91.3%) patients. Complete and partial responses were achieved in 16 (69.6%) and 5 (21.7%) patients, respectively. There were no patients with worse than grade III complications. We concluded that superselective intraarterial infusion therapy with a high dose of CDDP and STS was very effective for the management of advanced head and neck carcinomas and we recommend the implantable reservoir system for both CDDP and STS administration as an easy and low-invasive method. (author)

  10. Effect of pump limiter throat on pumping efficiency

    International Nuclear Information System (INIS)

    Ghendrih, P.; Grosman, A.; Samain, A.; Capes, H.; Morera, J.P.

    1988-01-01

    The necessary control of plasma edge density has led to the development of pump limiters to achieve this task. On Tore Supra, where a large part of the program is devoted to plasma edge studies, two types of such density control apparatus have been implemented, a set of pump limiters and the pumps associated to the ergodic divertor (magnetically assisted pump limiters). Generally two different kinds of pump limiters can be used, those with a throat which drives the plasma from the open edge plasma (SOL) to the neutralizer plate, and those without or with a very short throat. We are interested here in this aspect of the pump limiter concept, i.e. on the throat effect on neutral density build-up in the vicinity of the pumping plates (and hence on pumping efficieny). The underlying idea of this throat effect can be readily understood; indeed while the neutral capture in pump limiters without throats is only a ballistic effect, on expects the plasma to improve the efficiency of pump-limiters via plasma-neutral-sidewall interactions in the throat. This problem has been studied both numerically and analytically. The paper is divided as follows. In section 2, we describe the basic features of pump-limiters which are modelized by the numerical code Cezanne. Section 3 is devoted to the throat length effect considering in particular the neutral density profile in the throat and the neutral density buil-up as a function of the throat lenght. In section 4, we show that the plugging effect occurs for reasonnable values of throat lengths. An analytical value of the plugging length is discussed and compared to the values obtained numerically

  11. Pump cavitation and inducer design

    International Nuclear Information System (INIS)

    Heslenfeld, M.W.; Hes, M. de

    2002-01-01

    Details of past work on sodium pump development and cavitation studies executed mainly for SNR 300 were reported earlier. Among the requirements for large sodium pumps are long life (200000 hours up to 300000 hours) and small size of impeller and pump, fully meeting the process and design criteria. These criteria are the required 'Q, H, r characteristics' in combination with a low NPSH value and the avoidance of cavitation damage to the pump. The pump designer has to develop a sound hydraulic combination consisting of suction arrangement, impeller design and diffuser. On the other hand the designer is free to choose an optimal pump speed. The pump speed in its turn influences the rotor dynamic pump design and the pump drive. The introduction of the inducer as an integral part of the pump design is based on following advantages: no tip cavitation; (possible) cavitation bubbles move to the open centre due to centrifugal forces on the fluid; the head of the inducer improves the inlet conditions of the impeller. The aim of an inducer is the increase in the suction specific speed (SA value) of a pump whereby the inducer functions as a pressure source improving the impeller inlet conditions. With inducer-impeller combinations values up to SA=15000 are realistic. With the use of an inducer the overall pump sizes can be reduced with Ca. 30%. Pumps commonly available have SA values up to a maximum of ca. 10000. A development programme was executed for SNR 300 in order to reach an increase of the suction specific speed of the impeller from SA 8200 to SA 11000. Further studies to optimize pumps design for the follow up line introduced the 'inducer acting as a pre-impeller' development. This programme was executed in the period 1979-1981. At the FDO premises a scale 1 2.8 inducer impeller combination with a suction specific speed SA=15000 was developed, constructed and tested at the water test rig. This water test rig is equipped with a perspex pipe allowing also visualisation

  12. Mechanical pumping at low temperature

    International Nuclear Information System (INIS)

    Perin, J.P.; Claudet, G.; Disdier, F.

    1995-01-01

    This novel concept consist of a mechanical pump able to run at low temperature (25K). Since gas density varies inversely with temperature, this pump would deliver much higher mass flow rate than at room temperature for a given size. Advantages of this concept are order of magnitude reduction in size, weight, when compared to a conventional pump scaled to perform the same mass flow rate at room temperature. This pump would be a solution to allow continuously tritium extraction and minimize the mass inventory. (orig.)

  13. Proper Sizing of Circulation Pumps

    DEFF Research Database (Denmark)

    Tommerup, Henrik M.; Nørgaard, Jørgen

    2007-01-01

    The paper describes the preliminary results from field tests of replacing various types of old pumps used for circulating water in heating systems in single- and double-family houses with new types of pumps. The tests were carried out in Denmark for the Danish Electricity Savings Trust, but the r......The paper describes the preliminary results from field tests of replacing various types of old pumps used for circulating water in heating systems in single- and double-family houses with new types of pumps. The tests were carried out in Denmark for the Danish Electricity Savings Trust...

  14. High-vacuum plasma pump

    International Nuclear Information System (INIS)

    Dorodnov, A.M.; Minajchev, V.E.; Miroshkin, S.I.

    1980-01-01

    The action of an electric-arc high-vacuum pump intended for evacuating the volumes in which the operation processes are followed by a high gas evolution is considered. The operation of the pump is based on the principle of controlling the getter feed according to the gas load and effect of plasma sorbtion pumping. The pump performances are given. The starting pressure is about 5 Pa, the limiting residual pressure is about 5x10 -6 Pa, the pumping out rate of nitrogen in the pressure range 5x10 -5 -5x10 -3 Pa accounts for about 4000 l/s, the power consumption comes to 6 kW. Analyzing the results of the test operation of the pump, it has been concluded that its principal advantages are the high starting pressure, controlled getter feed rate and possibility of pumping out the gases which are usually pumped out with difficulty. The operation reliability of the pump is defined mainly by reliable operation of the ignition system of the vacuum arc [ru

  15. Mono pump equipment evaluation report

    International Nuclear Information System (INIS)

    1992-01-01

    A mobile pump has been designed, developed, and tested as part of an effort to increase oil spill response time, improve oil/water recovery efficiency and reduce cleanup and reclamation costs. The pump is mounted on an engine powered track carrier, and can be detached from the carrier and skidded into remote spill sites or transported by helicopter. The pump can safely recover highly volatile flammable substances such as condensate and gasoline, as well as heavy crude oil up to 5000 centipoise viscosity. It can pump up to 30 gal/min at zero head, and up to 1000 feet in a vertical direction. 13 figs

  16. High volumetric power density, non-enzymatic, glucose fuel cells.

    Science.gov (United States)

    Oncescu, Vlad; Erickson, David

    2013-01-01

    The development of new implantable medical devices has been limited in the past by slow advances in lithium battery technology. Non-enzymatic glucose fuel cells are promising replacement candidates for lithium batteries because of good long-term stability and adequate power density. The devices developed to date however use an "oxygen depletion design" whereby the electrodes are stacked on top of each other leading to low volumetric power density and complicated fabrication protocols. Here we have developed a novel single-layer fuel cell with good performance (2 μW cm⁻²) and stability that can be integrated directly as a coating layer on large implantable devices, or stacked to obtain a high volumetric power density (over 16 μW cm⁻³). This represents the first demonstration of a low volume non-enzymatic fuel cell stack with high power density, greatly increasing the range of applications for non-enzymatic glucose fuel cells.

  17. A feasibility study of digital tomosynthesis for volumetric dental imaging

    International Nuclear Information System (INIS)

    Cho, M K; Kim, H K; Youn, H; Kim, S S

    2012-01-01

    We present a volumetric dental tomography method that compensates for insufficient projection views obtained from limited-angle scans. The reconstruction algorithm is based on the backprojection filtering method which employs apodizing filters that reduce out-of-plane blur artifacts and suppress high-frequency noise. In order to accompolish this volumetric imaging two volume-reconstructed datasets are synthesized. These individual datasets provide two different limited-angle scans performed at orthogonal angles. The obtained reconstructed images, using less than 15% of the number of projection views needed for a full skull phantom scan, demonstrate the potential use of the proposed method in dental imaging applications. This method enables a much smaller radiation dose for the patient compared to conventional dental tomography.

  18. COMPARISON OF VOLUMETRIC REGISTRATION ALGORITHMS FOR TENSOR-BASED MORPHOMETRY.

    Science.gov (United States)

    Villalon, Julio; Joshi, Anand A; Toga, Arthur W; Thompson, Paul M

    2011-01-01

    Nonlinear registration of brain MRI scans is often used to quantify morphological differences associated with disease or genetic factors. Recently, surface-guided fully 3D volumetric registrations have been developed that combine intensity-guided volume registrations with cortical surface constraints. In this paper, we compare one such algorithm to two popular high-dimensional volumetric registration methods: large-deformation viscous fluid registration, formulated in a Riemannian framework, and the diffeomorphic "Demons" algorithm. We performed an objective morphometric comparison, by using a large MRI dataset from 340 young adult twin subjects to examine 3D patterns of correlations in anatomical volumes. Surface-constrained volume registration gave greater effect sizes for detecting morphometric associations near the cortex, while the other two approaches gave greater effects sizes subcortically. These findings suggest novel ways to combine the advantages of multiple methods in the future.

  19. Volumetric properties of ammonium nitrate in N,N-dimethylformamide

    International Nuclear Information System (INIS)

    Vranes, Milan; Dozic, Sanja; Djeric, Vesna; Gadzuric, Slobodan

    2012-01-01

    Highlights: ► We observed interactions and changes in the solution using volumetric properties. ► The greatest influence on the solvent–solvent interactions has temperature. ► The smallest influence temperature has on the ion–ion interactions. ► Temperature has no influence on concentrated systems and partially solvated melts. - Abstract: The densities of the ammonium nitrate in N,N-dimethylformamide (DMF) mixtures were measured at T = (308.15 to 348.15) K for different ammonium nitrate molalities in the range from (0 to 6.8404) mol·kg −1 . From the obtained density data, volumetric properties (apparent molar volumes and partial molar volumes) have been evaluated and discussed in the term of respective ionic and dipole interactions. From the apparent molar volume, determined at various temperatures, the apparent molar expansibility and the coefficients of thermal expansion were also calculated.

  20. Predicting positional error of MLC using volumetric analysis

    International Nuclear Information System (INIS)

    Hareram, E.S.

    2008-01-01

    IMRT normally using multiple beamlets (small width of the beam) for a particular field to deliver so that it is imperative to maintain the positional accuracy of the MLC in order to deliver integrated computed dose accurately. Different manufacturers have reported high precession on MLC devices with leaf positional accuracy nearing 0.1 mm but measuring and rectifying the error in this accuracy is very difficult. Various methods are used to check MLC position and among this volumetric analysis is one of the technique. Volumetric approach was adapted in our method using primus machine and 0.6cc chamber at 5 cm depth In perspex. MLC of 1 mm error introduces an error of 20%, more sensitive to other methods

  1. Reference volumetric samples of gamma-spectroscopic sources

    International Nuclear Information System (INIS)

    Taskaev, E.; Taskaeva, M.; Grigorov, T.

    1993-01-01

    The purpose of this investigation is to determine the requirements for matrices of reference volumetric radiation sources necessary for detector calibration. The first stage of this determination consists in analysing some available organic and nonorganic materials. Different sorts of food, grass, plastics, minerals and building materials have been considered, taking into account the various procedures of their processing (grinding, screening, homogenizing) and their properties (hygroscopy, storage life, resistance to oxidation during gamma sterilization). The procedures of source processing, sample preparation, matrix irradiation and homogenization have been determined. A rotation homogenizing device has been elaborated enabling to homogenize the matrix activity irrespective of the vessel geometry. 33 standard volumetric radioactive sources have been prepared: 14 - on organic matrix and 19 - on nonorganic matrix. (author)

  2. Determination of uranium by a gravimetric-volumetric titration method

    International Nuclear Information System (INIS)

    Krtil, J.

    1998-01-01

    A volumetric-gravimetric modification of a method for the determination of uranium based on the reduction of uranium to U (IV) in a phosphoric acid medium and titration with a standard potassium dichromate solution is described. More than 99% of the stoichiometric amount of the titrating solution is weighed and the remainder is added volumetrically by using the Mettler DL 40 RC Memotitrator. Computer interconnected with analytical balances collects continually the data on the analyzed samples and evaluates the results of determination. The method allows to determine uranium in samples of uranium metal, alloys, oxides, and ammonium diuranate by using aliquot portions containing 30 - 100 mg of uranium with the error of determination, expressed as the relative standard deviation, of 0.02 - 0.05%. (author)

  3. Two-dimensional random arrays for real time volumetric imaging

    DEFF Research Database (Denmark)

    Davidsen, Richard E.; Jensen, Jørgen Arendt; Smith, Stephen W.

    1994-01-01

    real time volumetric imaging system, which employs a wide transmit beam and receive mode parallel processing to increase image frame rate. Depth-of-field comparisons were made from simulated on-axis and off-axis beamplots at ranges from 30 to 160 mm for both coaxial and offset transmit and receive......Two-dimensional arrays are necessary for a variety of ultrasonic imaging techniques, including elevation focusing, 2-D phase aberration correction, and real time volumetric imaging. In order to reduce system cost and complexity, sparse 2-D arrays have been considered with element geometries...... selected ad hoc, by algorithm, or by random process. Two random sparse array geometries and a sparse array with a Mills cross receive pattern were simulated and compared to a fully sampled aperture with the same overall dimensions. The sparse arrays were designed to the constraints of the Duke University...

  4. Volumetric determination of tumor size abdominal masses. Problems -feasabilities

    International Nuclear Information System (INIS)

    Helmberger, H.; Bautz, W.; Sendler, A.; Fink, U.; Gerhardt, P.

    1995-01-01

    The most important indication for clinically reliable volumetric determination of tumor size in the abdominal region is monitoring liver metastases during chemotherapy. Determination of volume can be effectively realized using 3D reconstruction. Therefore, the primary data set must be complete and contiguous. The mass should be depicted strongly enhanced and free of artifacts. At present, this prerequisite can only be complied with using thin-slice spiral CT. Phantom studies have proven that a semiautomatic reconstruction algorithm is recommendable. The basic difficulties involved in volumetric determination of tumor size are the problems in differentiating active malignant mass and changes in the surrounding tissue, as well as the lack of histomorphological correlation. Possible indications for volumetry of gastrointestinal masses in the assessment of neoadjuvant therapeutic concepts are under scientific evaluation. (orig./MG) [de

  5. CO2 Capacity Sorbent Analysis Using Volumetric Measurement Approach

    Science.gov (United States)

    Huang, Roger; Richardson, Tra-My Justine; Belancik, Grace; Jan, Darrell; Knox, Jim

    2017-01-01

    In support of air revitalization system sorbent selection for future space missions, Ames Research Center (ARC) has performed CO2 capacity tests on various solid sorbents to complement structural strength tests conducted at Marshall Space Flight Center (MSFC). The materials of interest are: Grace Davison Grade 544 13X, Honeywell UOP APG III, LiLSX VSA-10, BASF 13X, and Grace Davison Grade 522 5A. CO2 capacity was for all sorbent materials using a Micromeritics ASAP 2020 Physisorption Volumetric Analysis machine to produce 0C, 10C, 25C, 50C, and 75C isotherms. These data are to be used for modeling data and to provide a basis for continued sorbent research. The volumetric analysis method proved to be effective in generating consistent and repeatable data for the 13X sorbents, but the method needs to be refined to tailor to different sorbents.

  6. In Vivo Real Time Volumetric Synthetic Aperture Ultrasound Imaging

    DEFF Research Database (Denmark)

    Bouzari, Hamed; Rasmussen, Morten Fischer; Brandt, Andreas Hjelm

    2015-01-01

    Synthetic aperture (SA) imaging can be used to achieve real-time volumetric ultrasound imaging using 2-D array transducers. The sensitivity of SA imaging is improved by maximizing the acoustic output, but one must consider the limitations of an ultrasound system, both technical and biological....... This paper investigates the in vivo applicability and sensitivity of volumetric SA imaging. Utilizing the transmit events to generate a set of virtual point sources, a frame rate of 25 Hz for a 90° x 90° field-of-view was achieved. Data were obtained using a 3.5 MHz 32 x 32 elements 2-D phased array...... transducer connected to the experimental scanner (SARUS). Proper scaling is applied to the excitation signal such that intensity levels are in compliance with the U.S. Food and Drug Administration regulations for in vivo ultrasound imaging. The measured Mechanical Index and spatial-peak- temporal...

  7. Neuroprotective Effects of Pomegranate Peel Extract after Chronic Infusion with Amyloid-β Peptide in Mice

    Science.gov (United States)

    Morzelle, Maressa Caldeira; Salgado, Jocelem Mastrodi; Telles, Milena; Mourelle, Danilo; Bachiega, Patricia; Buck, Hudson Sousa

    2016-01-01

    Alzheimer’s disease is a chronic and degenerative condition that had no treatment until recently. The current therapeutic strategies reduce progression of the disease but are expensive and commonly cause side effects that are uncomfortable for treated patients. Functional foods to prevent and/or treat many conditions, including neurodegenerative diseases, represent a promising field of study currently gaining attention. To this end, here we demonstrate the effects of pomegranate (Punica granatum) peel extract (PPE) regarding spatial memory, biomarkers of neuroplasticity, oxidative stress and inflammation in a mouse model of neurodegeneration. Male C57Bl/6 mice were chronically infused for 35 days with amyloid-β peptide 1–42 (Aβ) or vehicle (control) using mini-osmotic pumps. Another group, also infused with Aβ, was treated with PPE (p.o.– βA+PPE, 800 mg/kg/day). Spatial memory was evaluated in the Barnes maze. Animals treated with PPE and in the control group exhibited a reduction in failure to find the escape box, a finding that was not observed in the Aβ group. The consumption of PPE reduced amyloid plaque density, increased the expression of neurotrophin BDNF and reduced the activity of acetylcholinesterase enzyme. A reduction in lipid peroxidation and in the concentration of the pro-inflammatory cytokine TNF-α was also observed in the PPE group. No hepatic lesions were observed in animals treated with PPE. In conclusion, administration of pomegranate peel extract has neuroprotective effects involving multiple mechanisms to prevent establishment and progression of the neurodegenerative process induced by infusion with amyloid-β peptide in mice. PMID:27829013

  8. Low-dose copper infusion into the coronary circulation induces acute heart failure in diabetic rats: New mechanism of heart disease.

    Science.gov (United States)

    Cheung, Carlos Chun Ho; Soon, Choong Yee; Chuang, Chia-Lin; Phillips, Anthony R J; Zhang, Shaoping; Cooper, Garth J S

    2015-09-01

    Diabetes impairs copper (Cu) regulation, causing elevated serum Cu and urinary Cu excretion in patients with established cardiovascular disease; it also causes cardiomyopathy and chronic cardiac impairment linked to defective Cu homeostasis in rats. However, the mechanisms that link impaired Cu regulation to cardiac dysfunction in diabetes are incompletely understood. Chronic treatment with triethylenetetramine (TETA), a Cu²⁺-selective chelator, improves cardiac function in diabetic patients, and in rats with heart disease; the latter displayed ∼3-fold elevations in free Cu²⁺ in the coronary effluent when TETA was infused into their coronary arteries. To further study the nature of defective cardiac Cu regulation in diabetes, we employed an isolated-perfused, working-heart model in which we infused micromolar doses of Cu²⁺ into the coronary arteries and measured acute effects on cardiac function in diabetic and non-diabetic-control rats. Infusion of CuCl₂ solutions caused acute dose-dependent cardiac dysfunction in normal hearts. Several measures of baseline cardiac function were impaired in diabetic hearts, and these defects were exacerbated by low-micromolar Cu²⁺ infusion. The response to infused Cu²⁺ was augmented in diabetic hearts, which became defective at lower infusion levels and underwent complete pump failure (cardiac output = 0 ml/min) more often (P acute effects on cardiac function of pathophysiological elevations in coronary Cu²⁺. The effects of Cu²⁺ infusion occur within minutes in both control and diabetic hearts, which suggests that they are not due to remodelling. Heightened sensitivity to the acute effects of small elevations in Cu²⁺ could contribute substantively to impaired cardiac function in patients with diabetes and is thus identified as a new mechanism of heart disease. Copyright © 2015 Elsevier Inc. All rights reserved.

  9. Resonant Tunneling Spin Pump

    Science.gov (United States)

    Ting, David Z.

    2007-01-01

    The resonant tunneling spin pump is a proposed semiconductor device that would generate spin-polarized electron currents. The resonant tunneling spin pump would be a purely electrical device in the sense that it would not contain any magnetic material and would not rely on an applied magnetic field. Also, unlike prior sources of spin-polarized electron currents, the proposed device would not depend on a source of circularly polarized light. The proposed semiconductor electron-spin filters would exploit the Rashba effect, which can induce energy splitting in what would otherwise be degenerate quantum states, caused by a spin-orbit interaction in conjunction with a structural-inversion asymmetry in the presence of interfacial electric fields in a semiconductor heterostructure. The magnitude of the energy split is proportional to the electron wave number. Theoretical studies have suggested the possibility of devices in which electron energy states would be split by the Rashba effect and spin-polarized currents would be extracted by resonant quantum-mechanical tunneling.

  10. Volumetric formulation of lattice Boltzmann models with energy conservation

    OpenAIRE

    Sbragaglia, M.; Sugiyama, K.

    2010-01-01

    We analyze a volumetric formulation of lattice Boltzmann for compressible thermal fluid flows. The velocity set is chosen with the desired accuracy, based on the Gauss-Hermite quadrature procedure, and tested against controlled problems in bounded and unbounded fluids. The method allows the simulation of thermohydrodyamical problems without the need to preserve the exact space-filling nature of the velocity set, but still ensuring the exact conservation laws for density, momentum and energy. ...

  11. Volumetric Real-Time Imaging Using a CMUT Ring Array

    OpenAIRE

    Choe, Jung Woo; Oralkan, Ömer; Nikoozadeh, Amin; Gencel, Mustafa; Stephens, Douglas N.; O’Donnell, Matthew; Sahn, David J.; Khuri-Yakub, Butrus T.

    2012-01-01

    A ring array provides a very suitable geometry for forward-looking volumetric intracardiac and intravascular ultrasound imaging. We fabricated an annular 64-element capacitive micromachined ultrasonic transducer (CMUT) array featuring a 10-MHz operating frequency and a 1.27-mm outer radius. A custom software suite was developed to run on a PC-based imaging system for real-time imaging using this device.

  12. 3-dimensional charge collection efficiency measurements using volumetric tomographic reconstruction

    Energy Technology Data Exchange (ETDEWEB)

    Dobos, Daniel [CERN, Geneva (Switzerland)

    2016-07-01

    For a better understanding of the electrical field distribution of 3D semiconductor detectors and to allow efficiency based design improvements, a method to measure the 3D spatial charge collection efficiency of planar, 3D silicon and diamond sensors using 3D volumetric reconstruction techniques is possible. Simulation results and first measurements demonstrated the feasibility of this method and show that with soon available 10 times faster beam telescopes even small structures and efficiency differences will become measurable in few hours.

  13. Thermodynamic and volumetric databases and software for magnesium alloys

    Science.gov (United States)

    Kang, Youn-Bae; Aliravci, Celil; Spencer, Philip J.; Eriksson, Gunnar; Fuerst, Carlton D.; Chartrand, Patrice; Pelton, Arthur D.

    2009-05-01

    Extensive databases for the thermodynamic and volumetric properties of magnesium alloys have been prepared by critical evaluation, modeling, and optimization of available data. Software has been developed to access the databases to calculate equilibrium phase diagrams, heat effects, etc., and to follow the course of equilibrium or Scheil-Gulliver cooling, calculating not only the amounts of the individual phases, but also of the microstructural constituents.

  14. Volumetric 3D display using a DLP projection engine

    Science.gov (United States)

    Geng, Jason

    2012-03-01

    In this article, we describe a volumetric 3D display system based on the high speed DLPTM (Digital Light Processing) projection engine. Existing two-dimensional (2D) flat screen displays often lead to ambiguity and confusion in high-dimensional data/graphics presentation due to lack of true depth cues. Even with the help of powerful 3D rendering software, three-dimensional (3D) objects displayed on a 2D flat screen may still fail to provide spatial relationship or depth information correctly and effectively. Essentially, 2D displays have to rely upon capability of human brain to piece together a 3D representation from 2D images. Despite the impressive mental capability of human visual system, its visual perception is not reliable if certain depth cues are missing. In contrast, volumetric 3D display technologies to be discussed in this article are capable of displaying 3D volumetric images in true 3D space. Each "voxel" on a 3D image (analogous to a pixel in 2D image) locates physically at the spatial position where it is supposed to be, and emits light from that position toward omni-directions to form a real 3D image in 3D space. Such a volumetric 3D display provides both physiological depth cues and psychological depth cues to human visual system to truthfully perceive 3D objects. It yields a realistic spatial representation of 3D objects and simplifies our understanding to the complexity of 3D objects and spatial relationship among them.

  15. A Hierarchical Volumetric Shadow Algorithm for Single Scattering

    OpenAIRE

    Baran, Ilya; Chen, Jiawen; Ragan-Kelley, Jonathan Millar; Durand, Fredo; Lehtinen, Jaakko

    2010-01-01

    Volumetric effects such as beams of light through participating media are an important component in the appearance of the natural world. Many such effects can be faithfully modeled by a single scattering medium. In the presence of shadows, rendering these effects can be prohibitively expensive: current algorithms are based on ray marching, i.e., integrating the illumination scattered towards the camera along each view ray, modulated by visibility to the light source at each sample. Visibility...

  16. Systematic Parameterization, Storage, and Representation of Volumetric DICOM Data

    OpenAIRE

    Fischer, Felix; Selver, M. Alper; Gezer, Sinem; Dicle, O?uz; Hillen, Walter

    2015-01-01

    Tomographic medical imaging systems produce hundreds to thousands of slices, enabling three-dimensional (3D) analysis. Radiologists process these images through various tools and techniques in order to generate 3D renderings for various applications, such as surgical planning, medical education, and volumetric measurements. To save and store these visualizations, current systems use snapshots or video exporting, which prevents further optimizations and requires the storage of significant addi...

  17. In-Situ Spatial Variability Of Thermal Conductivity And Volumetric ...

    African Journals Online (AJOL)

    Studies of spatial variability of thermal conductivity and volumetric water content of silty topsoil were conduct-ed on a 0.6 ha site at Abeokuta, South-Western Nigeria. The thermal conductivity (k) was measured at depths of up to 0.06 m along four parallel profiles of 200 m long and at an average temperature of 25 C, using ...

  18. Bupivacaine constant continuous surgical wound infusion versus continuous epidural infusion for post cesarean section pain, randomized placebo-controlled study

    Directory of Open Access Journals (Sweden)

    Hossam A. ELShamaa

    2016-10-01

    Conclusion: The current study demonstrated that bupivacaine administered by continuous epidural infusion provided a significantly lower pain scores with mobilization, and hence better analgesia for post cesarean section pain in the first postoperative day compared to continuous bupivacaine wound infusion through fenestrated catheter using the constant flow PainFusor system.

  19. Early mechanism of action of arterially infused ethanol: an experimental study on the influence of infusion speed

    International Nuclear Information System (INIS)

    Han, Joon Koo

    1988-01-01

    Abdominal aortography and histopathologic examination after absolute ethanol infusion at fast (0.4cc/sec) and slow speed (0.04cc/sec) were performed on 16 rats (2 controls. 7 fast infusion group. 7 slow infusion group). Angiographic and histopathologic findings were correlated and the findings of slow and fast infusion groups were studied. The results are as follows: 1. Histopathologic findings of the fast infusion group revealed wide area of glomerular and tubular collapses, obliteration of the free space between the Bowmann's capsule and glomerulus, sloughing and loss of the endothelium, fresh thrombi attached to the wall, and cleavage of the muscle layer of the arteries. 2. Angiographic findings of the fast infusion group revealed luminal irregularity, early obstruction of the aorta and the renal arteries, and delayed circulation time. 3. Histopathologic findings of the slow infusion group revealed degenerated, coalesced red blood cell packed in the glomeruli, focal areas of severe glomerular and tubular damage on relatively normal background, endothelial and muscular damage of the arteries. 4. Angiographic findings of the slow infusion group revealed focal perfusion defect of the kidney, delayed circulation time, and mild luminal irregularity, but there was no obstruction of the major arteries. 5. In conclusion, author believes that endothelial damage and thrombus formation from the damaged vessel wall, as well as direct cytotoxicity and in situ emboli formation play a significant role in the embolic effect of absolute ethanol.

  20. Continuous indomethacin infusion may be less effective than bolus infusions for ductal closure in very low birth weight infants

    NARCIS (Netherlands)

    de Vries, NKS; Jagroep, FK; Jaarsma, AS; Elzenga, NJ; Bos, AF

    The effectiveness of continuous indomethacin (INDO) infusion versus bolus infusions for closure of patent ductus arteriosus (PDA) was investigated. The study design was an open-label case series (continuous INDO) with historic controls matched for gestational age (bolus INDO). Ductal closure rates

  1. Achieving Outcomes With Innovative Smart Pump Technology: Partnership, Planning, and Quality Improvement.

    Science.gov (United States)

    Lehr, Jennifer; Vitoux, Rachel R; Zavotsky, Kathleen Evanovich; Pontieri-Lewis, Vicky; Colineri, Lori

    2018-04-09

    A 5-time designated Magnet academic medical center partnered with its infusion systems supplier to successfully integrate 1327 smart pumps across 45 departments with an aggressive 3-month timeline. The team also achieved quality improvement (QI) outcomes through increased drug library compliance and decreased alerts with their new technology. This large academic medical center needed to implement innovative wireless infusion pump technology in a short time frame. The approach involved a strong partnership from the medical center and the supplier, with extensive planning and collaboration among the clinical nurse specialists and consultants from both organizations to accomplish QI goals. Lean principles were also followed to enhance efficiency and accountability. Quality improvement outcomes included 100% drug library compliance across all 6 intensive care units, a decrease in pump alert rates from 4.18% to 0.79%, and a decrease in pump programming correction rate from 0.36% to 0.06%. A partnership led to a large implementation being completed efficiently across an academic medical center. Through these joint efforts, quality of care was improved within a short period of time.This is an open-access article distributed under the terms of the Creative Commons Attribution-Non Commercial-No Derivatives License 4.0 (CCBY-NC-ND), where it is permissible to download and share the work provided it is properly cited. The work cannot be changed in any way or used commercially without permission from the journal.

  2. Three-dimensional volumetric display by inclined-plane scanning

    Science.gov (United States)

    Miyazaki, Daisuke; Eto, Takuma; Nishimura, Yasuhiro; Matsushita, Kenji

    2003-05-01

    A volumetric display system based on three-dimensional (3-D) scanning that uses an inclined two-dimensional (2-D) image is described. In the volumetric display system a 2-D display unit is placed obliquely in an imaging system into which a rotating mirror is inserted. When the mirror is rotated, the inclined 2-D image is moved laterally. A locus of the moving image can be observed by persistence of vision as a result of the high-speed rotation of the mirror. Inclined cross-sectional images of an object are displayed on the display unit in accordance with the position of the image plane to observe a 3-D image of the object by persistence of vision. Three-dimensional images formed by this display system satisfy all the criteria for stereoscopic vision. We constructed the volumetric display systems using a galvanometer mirror and a vector-scan display unit. In addition, we constructed a real-time 3-D measurement system based on a light section method. Measured 3-D images can be reconstructed in the 3-D display system in real time.

  3. A volumetric three-dimensional digital light photoactivatable dye display

    Science.gov (United States)

    Patel, Shreya K.; Cao, Jian; Lippert, Alexander R.

    2017-07-01

    Volumetric three-dimensional displays offer spatially accurate representations of images with a 360° view, but have been difficult to implement due to complex fabrication requirements. Herein, a chemically enabled volumetric 3D digital light photoactivatable dye display (3D Light PAD) is reported. The operating principle relies on photoactivatable dyes that become reversibly fluorescent upon illumination with ultraviolet light. Proper tuning of kinetics and emission wavelengths enables the generation of a spatial pattern of fluorescent emission at the intersection of two structured light beams. A first-generation 3D Light PAD was fabricated using the photoactivatable dye N-phenyl spirolactam rhodamine B, a commercial picoprojector, an ultraviolet projector and a custom quartz imaging chamber. The system displays a minimum voxel size of 0.68 mm3, 200 μm resolution and good stability over repeated `on-off' cycles. A range of high-resolution 3D images and animations can be projected, setting the foundation for widely accessible volumetric 3D displays.

  4. Volumetric full-range magnetomotive optical coherence tomography

    Science.gov (United States)

    Ahmad, Adeel; Kim, Jongsik; Shemonski, Nathan D.; Marjanovic, Marina; Boppart, Stephen A.

    2014-01-01

    Abstract. Magnetomotive optical coherence tomography (MM-OCT) can be utilized to spatially localize the presence of magnetic particles within tissues or organs. These magnetic particle-containing regions are detected by using the capability of OCT to measure small-scale displacements induced by the activation of an external electromagnet coil typically driven by a harmonic excitation signal. The constraints imposed by the scanning schemes employed and tissue viscoelastic properties limit the speed at which conventional MM-OCT data can be acquired. Realizing that electromagnet coils can be designed to exert MM force on relatively large tissue volumes (comparable or larger than typical OCT imaging fields of view), we show that an order-of-magnitude improvement in three-dimensional (3-D) MM-OCT imaging speed can be achieved by rapid acquisition of a volumetric scan during the activation of the coil. Furthermore, we show volumetric (3-D) MM-OCT imaging over a large imaging depth range by combining this volumetric scan scheme with full-range OCT. Results with tissue equivalent phantoms and a biological tissue are shown to demonstrate this technique. PMID:25472770

  5. Reducing uncertainties in volumetric image based deformable organ registration

    International Nuclear Information System (INIS)

    Liang, J.; Yan, D.

    2003-01-01

    Applying volumetric image feedback in radiotherapy requires image based deformable organ registration. The foundation of this registration is the ability of tracking subvolume displacement in organs of interest. Subvolume displacement can be calculated by applying biomechanics model and the finite element method to human organs manifested on the multiple volumetric images. The calculation accuracy, however, is highly dependent on the determination of the corresponding organ boundary points. Lacking sufficient information for such determination, uncertainties are inevitable--thus diminishing the registration accuracy. In this paper, a method of consuming energy minimization was developed to reduce these uncertainties. Starting from an initial selection of organ boundary point correspondence on volumetric image sets, the subvolume displacement and stress distribution of the whole organ are calculated and the consumed energy due to the subvolume displacements is computed accordingly. The corresponding positions of the initially selected boundary points are then iteratively optimized to minimize the consuming energy under geometry and stress constraints. In this study, a rectal wall delineated from patient CT image was artificially deformed using a computer simulation and utilized to test the optimization. Subvolume displacements calculated based on the optimized boundary point correspondence were compared to the true displacements, and the calculation accuracy was thereby evaluated. Results demonstrate that a significant improvement on the accuracy of the deformable organ registration can be achieved by applying the consuming energy minimization in the organ deformation calculation

  6. Survey of pumps for tritium gas

    International Nuclear Information System (INIS)

    Dowell, T.M.

    1983-05-01

    This report considers many different types of pumps for their possible use in pumping tritium gas in the low, intermediate and high vacuum ranges. No one type of pump is suitable for use over the wide range of pumping pressure required in a typical pumping system. The favoured components for such a system are: bellows pump (low vacuum); orbiting scroll pump (intermediate vacuum); magnetically suspended turbomolecular pump (high vacuum); cryopump (high vacuum). Other pumps which should be considered for possible future development are: mound modified vane pump; SRTI wobble pump; roots pump with canned motor. It is proposed that a study be made of a future tritium pumping system in a Canadian tritium facility, e.g. a tritium laboratory

  7. LMR [liquid metal reactor] centrifugal pump coastdowns

    International Nuclear Information System (INIS)

    Dunn, F.E.; Malloy, D.J.

    1987-01-01

    A centrifugal pump model which describes the interrelationships of the pump discharge flowrate, pump speed, shaft torque and dynamic head has been implemented based upon existing models. Specifically, the pump model is based upon the dimensionless-homologous pump theory of Wylie and Streeter. Given data from a representative pump, homologous theory allows one to predict the transient characteristics of similarly sized pumps. This homologous pump model has been implemented into both the one-dimensional SASSYS-1 systems analysis code and the three-dimensional COMMIX-1A code. Comparisons have been made both against other pump models (CRBR) and actual pump coastdown data (EBR-II and FFTF). Agreement with this homologous pump model has been excellent. Additionally, these comparisons indicate the validity of applying the medium size pump data of Wylie and Streeter to a range of typical LMR centrifugal pumps

  8. Work plan, AP-102 mixer pump removal and pump replacement

    International Nuclear Information System (INIS)

    Jimenez, R.F.

    1994-01-01

    The objective of this work plan is to plan the steps and estimate the costs required to remove the failed AP-102 mixer pump, and to plan and estimate the cost of the necessary design and specification work required to order a new, but modified, mixer pump including the pump and pump pit energy absorbing design. The main hardware required for the removal of the mixer is as follows: a flexible receiver and blast shield; a metal container for the pulled mixer pump; and a trailer and strongback to haul and manipulate the container. Additionally: a gamma scanning device will be needed to detect the radioactivity emanating from the mixer as it is pulled from the tank; a water spray system will be required to remove tank waste from the surface of the mixer as it is pulled from the AP-102 tank; and a lifting yoke to lift the mixer from the pump pit (the SY-101 Mixer Lifting Yoke will be used). A ''green house'' will have to be erected over the AP-102 pump pit and an experienced Hoisting and Rigging crew must be assembled and trained in mixer pump removal methods before the actual removal is undertaken

  9. Diode-pumped laser with improved pumping system

    Science.gov (United States)

    Chang, Jim J.

    2004-03-09

    A laser wherein pump radiation from laser diodes is delivered to a pump chamber and into the lasing medium by quasi-three-dimensional compound parabolic concentrator light channels. The light channels have reflective side walls with a curved surface and reflective end walls with a curved surface. A flow tube between the lasing medium and the light channel has a roughened surface.

  10. Analysis of event logs from syringe pumps: a retrospective pilot study to assess possible effects of syringe pumps on safety in a university hospital critical care unit in Germany.

    Science.gov (United States)

    Kastrup, Marc; Balzer, Felix; Volk, Thomas; Spies, Claudia

    2012-07-01

    Medication errors occur in approximately one out of five doses in a typical hospital setting. Patients in the intensive care unit (ICU) are particularly susceptible to errors during the application of intravenous drugs as they receive numerous potent drugs applied by syringe pumps. The aim of this study was to analyse the effects on potential harmful medication errors and to address factors that have potential for improving medication safety after the introduction of a standardized drug library into syringe pumps with integrated decision support systems. A team of physicians and nurses developed a dataset that defined standardized drug concentrations, application rates and alert limits to prevent accidental overdosing of intravenous medications. This dataset was implemented in 100 syringe pumps with the ability to log programming errors, alerts, reprogramming events and overrides ('smart pumps'). In this retrospective pilot study, all pump-related transaction data were obtained from the pump logs, by downloading the data from the pumps, covering 20 months of use between 1 April 2008 and 30 November 2009. Patient data were gathered from the electronic patient charts. The study was performed in a cardiothoracic ICU of the Charité University Hospital, Berlin, Germany. A total of 7884 patient treatment days and 133,601 infusion starts were evaluated. The drug library with the features of the dose rate was used in 92.8% of the syringe pump starts, in 1.5% of the starts a manual dosing mode without the use of the drug library was used and in 5.7% of the starts the mode 'mL/h', without any calculation features, was used. The most frequently used drugs were vasoactive drugs, followed by sedation medication. The user was alerted for a potentially harmful overdosing in 717 cases and in 66 cases the pumps were reprogrammed after the alert. During the early morning hours a higher rate of alarms was generated by the pumps, compared with the rest of the day. Syringe pumps with

  11. Pumps in wearable ultrafiltration devices: pumps in wuf devices.

    Science.gov (United States)

    Armignacco, Paolo; Garzotto, Francesco; Bellini, Corrado; Neri, Mauro; Lorenzin, Anna; Sartori, Marco; Ronco, Claudio

    2015-01-01

    The wearable artificial kidney (WAK) is a device that is supposed to operate like a real kidney, which permits prolonged, frequent, and continuous dialysis treatments for patients with end-stage renal disease (ESRD). Its functioning is mainly related to its pumping system, as well as to its dialysate-generating and alarm/shutoff ones. A pump is defined as a device that moves fluids by mechanical action. In such a context, blood pumps pull blood from the access side of the dialysis catheter and return the blood at the same rate of flow. The main aim of this paper is to review the current literature on blood pumps, describing the way they have been functioning thus far and how they are being engineered, giving details about the most important parameters that define their quality, thus allowing the production of a radar comparative graph, and listing ideal pumps' features. © 2015 S. Karger AG, Basel.

  12. Design of Pumps for Water Hydraulic Systems

    DEFF Research Database (Denmark)

    Klit, Peder; Olsen, Stefan; Bech, Thomas Nørgaard

    1999-01-01

    This paper considers the development of two pumps for water hydraulic applications. The pumps are based on two different working principles: The Vane-type pump and the Gear-type pump. Emphasis is put on the considerations that should be made to account for water as the hydraulic fluid.......KEYWORDS: water, pump, design, vane, gear....

  13. 46 CFR 119.520 - Bilge pumps.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Bilge pumps. 119.520 Section 119.520 Shipping COAST... Ballast Systems § 119.520 Bilge pumps. (a) Each vessel must be provided with bilge pumps in accordance... have a portable hand bilge pump that must be: (1) Capable of pumping water, but not necessarily...

  14. 46 CFR 154.1135 - Pumps.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 5 2010-10-01 2010-10-01 false Pumps. 154.1135 Section 154.1135 Shipping COAST GUARD... Pumps. (a) Water to the water spray system must be supplied by: (1) A pump that is only for the use of the system; (2) A fire pump; or (3) A pump specially approved by the Commandant (CG-522). (b...

  15. 33 CFR 157.126 - Pumps.

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Pumps. 157.126 Section 157.126... Washing (COW) System on Tank Vessels Design, Equipment, and Installation § 157.126 Pumps. (a) Crude oil must be supplied to the COW machines by COW system pumps or cargo pumps. (b) The pumps under paragraph...

  16. Chronic postthoracotomy pain and perioperative ketamine infusion.

    Science.gov (United States)

    Hu, Jie; Liao, Qin; Zhang, Fan; Tong, Jianbin; Ouyang, Wen

    2014-06-01

    The objectives of this study were to investigate whether continuous intravenous ketamine during the first 72 hours after thoracotomy could reduce the incidence and intensity of chronic postthoracotomy pain (CPTP) and to define the incidence and risk factors of CPTP. Seventy-eight patients receiving thoracotomy for lung tumor (benign or malignant) were randomly divided into two groups: ketamine group (n = 31) and control groups (n = 47). Patients in the ketamine group received intravenous ketamine 1 mg/kg before incision, followed by 2 μg/kg/minute infusion for 72 hours plus sufentanil patient-controlled intravenous analgesia after thoracotomy. Patients in the control group received intravenous a 0.9% normal saline and infusion plus sufentanil patient-controlled intravenous analgesia. The solutions patients received were blinded. The numerical rating scale (NRS) pain scores and the incidence and risk factors of CPTP were recorded during the first 6 months after surgery. Compared with control group, the incidence of chronic pain in the ketamine group did not decrease at 2 months (χ(2) = 1.599, P = .206) and 6 months (χ(2) = 0.368, P = .544) after surgery. Postoperative pain scores in the ketamine group were not significantly different from those of the control group patients at 2 months (U = 677.5, P = .593) and 6 months (U = 690.5, P = .680). The incidence of CPTP was 78.2% (61/78) at 2 months and 53.8% (42/78) at 6 months after surgery. Retractor used time (OR = 5.811, P = .002), inadequate acute pain control (NRS ≥ 5) (OR = 5.425, P = .048), and chemotherapy (OR = 3.784, P = .056) were independent risk factors for chronic postthoracotomy pain. The authors conclude that continuous intravenous ketamine (2 μg/kg/min) during the first 72 hours after thoracotomy was not beneficial to prevent chronic postthoracotomy pain. The independent risk factors for chronic postthoracotomy pain were retractor used time, inadequate acute pain control, and chemotherapy.

  17. Benefits and risks of using smart pumps to reduce medication error rates: a systematic review.

    Science.gov (United States)

    Ohashi, Kumiko; Dalleur, Olivia; Dykes, Patricia C; Bates, David W

    2014-12-01

    Smart infusion pumps have been introduced to prevent medication errors and have been widely adopted nationally in the USA, though they are not always used in Europe or other regions. Despite widespread usage of smart pumps, intravenous medication errors have not been fully eliminated. Through a systematic review of recent studies and reports regarding smart pump implementation and use, we aimed to identify the impact of smart pumps on error reduction and on the complex process of medication administration, and strategies to maximize the benefits of smart pumps. The medical literature related to the effects of smart pumps for improving patient safety was searched in PUBMED, EMBASE, and the Cochrane Central Register of Controlled Trials (CENTRAL) (2000-2014) and relevant papers were selected by two researchers. After the literature search, 231 papers were identified and the full texts of 138 articles were assessed for eligibility. Of these, 22 were included after removal of papers that did not meet the inclusion criteria. We assessed both the benefits and negative effects of smart pumps from these studies. One of the benefits of using smart pumps was intercepting errors such as the wrong rate, wrong dose, and pump setting errors. Other benefits include reduction of adverse drug event rates, practice improvements, and cost effectiveness. Meanwhile, the current issues or negative effects related to using smart pumps were lower compliance rates of using smart pumps, the overriding of soft alerts, non-intercepted errors, or the possibility of using the wrong drug library. The literature suggests that smart pumps reduce but do not eliminate programming errors. Although the hard limits of a drug library play a main role in intercepting medication errors, soft limits were still not as effective as hard limits because of high override rates. Compliance in using smart pumps is key towards effectively preventing errors. Opportunities for improvement include upgrading drug

  18. High temperature thermoacoustic heat pump

    Energy Technology Data Exchange (ETDEWEB)

    Tijani, H.; Spoelstra, S. [Energy research Centre of the Netherlands, 1755 ZG Petten (Netherlands)

    2012-06-15

    Thermoacoustic technology can provide new types of heat pumps that can be deployed in different applications. A thermoacoustic heat pumps can for example be applied in dwellings to generate cooling or heating. Typically, space and water heating makes up about 60% of domestics and offices energy consumption. The application of heat pumps can contribute to achieve energy savings and environmental benefits by reducing CO2 and NOx emissions. This paper presents the study of a laboratory scale thermoacoustic-Stirling heat pump operating between 10C and 80C which can be applied in domestics and offices. The heat pump is driven by a thermoacoustic-Stirling engine. The experimental results show that the heat pump pumps 250 W of heat at 60C at a drive ratio of 3.6% and 200 W at 80C at a drive ratio of 3.5 %. The performance for both cases is about 40% of the Carnot performance. The design, construction, and performance measurements of the heat pump will be presented and discussed.

  19. Review of magnetohydrodynamic pump applications

    Directory of Open Access Journals (Sweden)

    O.M. Al-Habahbeh

    2016-06-01

    Full Text Available Magneto-hydrodynamic (MHD principle is an important interdisciplinary field. One of the most important applications of this effect is pumping of materials that are hard to pump using conventional pumps. In this work, the progress achieved in this field is surveyed and organized according to the type of application. The literature of the past 27 years is searched for the major developments of MHD applications. MHD seawater thrusters are promising for a variety of applications requiring high flow rates and velocity. MHD molten metal pump is important replacement to conventional pumps because their moving parts cannot stand the molten metal temperature. MHD molten salt pump is used for nuclear reactor coolants due to its no-moving-parts feature. Nanofluid MHD pumping is a promising technology especially for bioapplications. Advantages of MHD include silence due to no-moving-parts propulsion. Much progress has been made, but with MHD pump still not suitable for wider applications, this remains a fertile area for future research.

  20. Direct solar-pumped lasers

    Science.gov (United States)

    Lee, J. H.; Shiu, Y. J.; Weaver, W. R.

    1980-01-01

    The feasibility of direct solar pumping of an iodine photodissociation laser at lambda = 1.315 microns was investigated. Threshold inversion density and effect of elevated temperature (up to 670 K) on the laser output were measured. These results and the concentration of solar radiation required for the solar pumped iodine laser are discussed.

  1. Heat pumping in nanomechanical systems.

    Science.gov (United States)

    Chamon, Claudio; Mucciolo, Eduardo R; Arrachea, Liliana; Capaz, Rodrigo B

    2011-04-01

    We propose using a phonon pumping mechanism to transfer heat from a cold to a hot body using a propagating modulation of the medium connecting the two bodies. This phonon pump can cool nanomechanical systems without the need for active feedback. We compute the lowest temperature that this refrigerator can achieve. © 2011 American Physical Society

  2. Heat pumping in nanomechanical systems

    OpenAIRE

    Chamon, Claudio; Mucciolo, Eduardo R.; Arrachea, Liliana; Capaz, Rodrigo B.

    2010-01-01

    We propose using a phonon pumping mechanism to transfer heat from a cold to a hot body using a propagating modulation of the medium connecting the two bodies. This phonon pump can cool nanomechanical systems without the need for active feedback. We compute the lowest temperature that this refrigerator can achieve.

  3. High Temperature Thermoacoustic Heat Pump

    Energy Technology Data Exchange (ETDEWEB)

    Tijani, H.; Spoelstra, S. [ECN Biomass and Energy Efficiency, Petten (Netherlands)

    2012-07-15

    Thermoacoustic technology can provide new types of heat pumps that can be deployed in different applications. Thermoacoustic heat pumps can for example be applied in dwellings to generate cooling or heating. Typically, space and water heating makes up about 60% of domestic and office energy consumption. The application of heat pumps can contribute to achieve energy savings and environmental benefits by reducing CO2 and NOx emissions. This paper presents the study of a laboratory scale thermoacoustic-Stirling heat pump operating between 10C and 80C which can be applied in domestics and offices. The heat pump is driven by a thermoacoustic-Stirling engine. The experimental results show that the heat pump pumps 250 W of heat at 60C at a drive ratio of 3.6 % and 200 W at 80C at a drive ratio of 3.5 %. The performance for both cases is about 40% of the Carnot performance. The design, construction, and performance measurements of the heat pump will be presented and discussed.

  4. Reflection of centrifugal pumps maintenance

    International Nuclear Information System (INIS)

    Mozos Fernandez, V.

    2010-01-01

    The aim of this work is to prove that is not necessary a deep and complex knowledge to manage the centrifugal pumps maintenance. According to the author, only deep but single technical knowledge about causes of breakdowns in the different and simple component parts of the pumps, are required. (Author)

  5. The Plasma Membrane Calcium Pump

    Science.gov (United States)

    Rasmussen, H.

    1983-01-01

    Three aspect of cellular calcium metabolism in animal cells was discussed including the importance of the plasma membrane in calcium homeostasis, experiments dealing with the actual mechanism of the calcium pump, and the function of the pump in relationship to the mitochondria and to the function of calmodulin in the intact cell.

  6. Intraarterial infusion chemotherapy for the treatment of metastatic liver cancer

    International Nuclear Information System (INIS)

    Arai, Yasuaki; Kido, Choichiro

    1987-01-01

    Some techniques of the most recent interventional radiology are very useful for the treatment of metastatic liver cancer and changing the style of hepatic infusion chemotherapy. This report shows our latest results and methods of hepatic infusion chemotherapy for metastatic liver cancer. 1. For the catheter placement, a new catheterization route via the left subclavian artery into the hepatic artery was developed and performed in 132 cases. Superselective catheterization succeeded in 123 cases (93.2 %). This procedure is less invasive than laparotomy and less troublesome than other percutaneous routes. 2. For useful infusion system, an implantable injection port ''Reservoir'' was developed and it was used in 87 cases. This method makes arterial infusion chemotherapy easy, and imploves their quality of life. 3. To acquire adequate drug delivery, arterial redistribution by steel coils was done, and 109 arteries in 80 cases were occluded. This method is very useful to make multiple hepatic artery single and it is important to avoid gasroduodenal complications. 4. Now, using these techniques, the phase II study of 5FU, ADM, MMC combined hepatic infusion in patients with non-resectable metastatic liver cancer is done. Up to this time, such a phase study on arterial infusion chemotherapy was difficult because of technical problems, but these new techniques make it possible. In conclusion, these new methods change the style and conception of hepatic infusion, and these make much progress on the treatment of patients with metastatic liver cancer. (author)

  7. Self pumping magnetic cooling

    International Nuclear Information System (INIS)

    Chaudhary, V; Wang, Z; Ray, A; Ramanujan, R V; Sridhar, I

    2017-01-01

    Efficient thermal management and heat recovery devices are of high technological significance for innovative energy conservation solutions. We describe a study of a self-pumping magnetic cooling device, which does not require external energy input, employing Mn–Zn ferrite nanoparticles suspended in water. The device performance depends strongly on magnetic field strength, nanoparticle content in the fluid and heat load temperature. Cooling (Δ T ) by ∼20 °C and ∼28 °C was achieved by the application of 0.3 T magnetic field when the initial temperature of the heat load was 64 °C and 87 °C, respectively. These experiments results were in good agreement with simulations performed with COMSOL Multiphysics. Our system is a self-regulating device; as the heat load increases, the magnetization of the ferrofluid decreases; leading to an increase in the fluid velocity and consequently, faster heat transfer from the heat source to the heat sink. (letter)

  8. Electric Turbo Pump

    Science.gov (United States)

    Steckler, Jessica

    2017-01-01

    NASA is working in junction with another company on the Electric Turbo Pump. Analysis of the impeller, including the blades, volute housing, and associated components, will take place in ANSYS. Contours of the deformed and stress were recorded to assess the parts. Campbell diagrams will be considered as mentioned to find the operating regions of the impeller and volute housing, more specifically what speed is ideal to ensure that the impeller does not begin to vibrate at a frequency that will break it. More than one material will be examined as per request by the designer to determine which material is more cost efficient, easy to machine, and can withstand the stress values that will be placed on it.

  9. Electric fluid pump

    Science.gov (United States)

    Van Dam, Jeremy Daniel; Turnquist, Norman Arnold; Raminosoa, Tsarafidy; Shah, Manoj Ramprasad; Shen, Xiaochun

    2015-09-29

    An electric machine is presented. The electric machine includes a hollow rotor; and a stator disposed within the hollow rotor, the stator defining a flow channel. The hollow rotor includes a first end portion defining a fluid inlet, a second end portion defining a fluid outlet; the fluid inlet, the fluid outlet, and the flow channel of the stator being configured to allow passage of a fluid from the fluid inlet to the fluid outlet via the flow channel; and wherein the hollow rotor is characterized by a largest cross-sectional area of hollow rotor, and wherein the flow channel is characterized by a smallest cross-sectional area of the flow channel, wherein the smallest cross-sectional area of the flow channel is at least about 25% of the largest cross-sectional area of the hollow rotor. An electric fluid pump and a power generation system are also presented.

  10. Dual source heat pump

    Science.gov (United States)

    Ecker, Amir L.; Pietsch, Joseph A.

    1982-01-01

    What is disclosed is a heat pump apparatus for conditioning a fluid characterized by a fluid handler and path for circulating the fluid in heat exchange relationship with a refrigerant fluid; at least two refrigerant heat exchangers, one for effecting heat exchange with the fluid and a second for effecting heat exchange between refrigerant and a heat exchange fluid and the ambient air; a compressor for efficiently compressing the refrigerant; at least one throttling valve for throttling liquid refrigerant; a refrigerant circuit; refrigerant; a source of heat exchange fluid; heat exchange fluid circulating device and heat exchange fluid circuit for circulating the heat exchange fluid in heat exchange relationship with the refrigerant; and valves or switches for selecting the heat exchangers and direction of flow of the refrigerant therethrough for selecting a particular mode of operation. The heat exchange fluid provides energy for defrosting the second heat exchanger when operating in the air source mode and also provides a alternate source of heat.

  11. Insulin Pump and CGM Usage in the United States and Germany

    Science.gov (United States)

    Walsh, John; Roberts, Ruth; Weber, Dietmar; Faber-Heinemann, Gabriele; Heinemann, Lutz

    2015-01-01

    Background: This survey collected and evaluated user responses about routine tasks and preferences regarding insulin pumps and infusion sets (IIS) with comparison of intercountry differences between the United States (US) and Germany (GER), chosen for their large insulin pump populations. Methods: A total of 985 subjects (534 US, 451 GER; 60% female) with type 1 diabetes on pump therapy anonymously answered 20 pump-related questions. US subjects also answered 11 questions about continuous glucose monitoring (CGM) usage. Results: Length of use of insulin cartridges is shorter in US than in GER, mean (SD) 4.3 (5.0) versus 5.3 (3.2) days (P 3 days vs 7.7% for <3 days; P < .01), and with use of an auto-insertion device (vs manual IIS insertion) in the US (7.2% vs 6.9%), but not in GER (7.7% vs 7.9%). Only 47% of pump wearers stated that they were “very satisfied” with their pump (49% US vs 45% GER, ns). However, 98% would recommend the pump to others (95% vs 93%, ns). Analysis of CGM questions showed that 297 (60%) of 496 US responders currently wore one. Of these, 84% said they would recommend CGM to others. CGM wearers who stated they were “very satisfied” with their CGM had lower HbA1c than those who said they were “partly satisfied” (6.9% vs 7.2%). Conclusions: This survey shows interesting differences in real-world use of insulin pumps in 2 large markets, and suggests areas where insulin pumps and CGMs might be improved. PMID:26071425

  12. High temperature industrial heat pumps

    Energy Technology Data Exchange (ETDEWEB)

    Berghmans, J. (Louvain Univ., Heverlee (Belgium). Inst. Mechanica)

    1990-01-01

    The present report intends to describe the state of the art of high temperature industrial heat pumps. A description is given of present systems on the market. In addition the research and development efforts on this subject are described. Compression (open as well as closed cycle) systems, as well as absorption heat pumps (including transformers), are considered. This state of the art description is based upon literature studies performed by a team of researchers from the Katholieke Universiteit Leuven, Belgium. The research team also analysed the economics of heat pumps of different types under the present economic conditions. The heat pumps are compared with conventional heating systems. This analysis was performed in order to evaluate the present condition of the heat pump in the European industry.

  13. Accuracy of a new patch pump based on a microelectromechanical system (MEMS) compared to other commercially available insulin pumps: results of the first in vitro and in vivo studies.

    Science.gov (United States)

    Borot, Sophie; Franc, Sylvia; Cristante, Justine; Penfornis, Alfred; Benhamou, Pierre-Yves; Guerci, Bruno; Hanaire, Hélène; Renard, Eric; Reznik, Yves; Simon, Chantal; Charpentier, Guillaume

    2014-11-01

    The JewelPUMP™ (JP) is a new patch pump based on a microelectromechanical system that operates without any plunger. The study aimed to evaluate the infusion accuracy of the JP in vitro and in vivo. For the in vitro studies, commercially available pumps meeting the ISO standard were compared to the JP: the MiniMed® Paradigm® 712 (MP), Accu-Chek® Combo (AC), OmniPod® (OP), Animas® Vibe™ (AN). Pump accuracy was measured over 24 hours using a continuous microweighing method, at 0.1 and 1 IU/h basal rates. The occlusion alarm threshold was measured after a catheter occlusion. The JP, filled with physiological serum, was then tested in 13 patients with type 1 diabetes simultaneously with their own pump for 2 days. The weight difference was used to calculate the infused insulin volume. The JP showed reduced absolute median error rate in vitro over a 15-minute observation window compared to other pumps (1 IU/h): ±1.02% (JP) vs ±1.60% (AN), ±1.66% (AC), ±2.22% (MP), and ±4.63% (OP), P pumps: 21 (19; 25) minutes vs 90 (85; 95), 58 (42; 74), and 143 (132; 218) minutes (AN, AC, MP), P pumps (-2.2 ± 5.6% vs -0.37 ± 4.0%, P = .25). The JP was found to be easier to wear than conventional pumps. The JP is more precise over a short time period, more sensitive to catheter occlusion, well accepted by patients, and consequently, of potential interest for a closed-loop insulin delivery system. © 2014 Diabetes Technology Society.

  14. Identification of infusion strategy for achieving repeatable nanoparticle distribution and quantification of thermal dosage using micro-CT Hounsfield unit in magnetic nanoparticle hyperthermia.

    Science.gov (United States)

    LeBrun, Alexander; Joglekar, Tejashree; Bieberich, Charles; Ma, Ronghui; Zhu, Liang

    2016-01-01

    The objective of this study was to identify an injection strategy leading to repeatable nanoparticle deposition patterns in tumours and to quantify volumetric heat generation rate distribution based on micro-CT Hounsfield unit (HU) in magnetic nanoparticle hyperthermia. In vivo animal experiments were performed on graft prostatic cancer (PC3) tumours in immunodeficient mice to investigate whether lowering ferrofluid infusion rate improves control of the distribution of magnetic nanoparticles in tumour tissue. Nanoparticle distribution volume obtained from micro-CT scan was used to evaluate spreading of the nanoparticles from the injection site in tumours. Heating experiments were performed to quantify relationships among micro-CT HU values, local nanoparticle concentrations in the tumours, and the ferrofluid-induced volumetric heat generation rate (q(MNH)) when nanoparticles were subject to an alternating magnetic field. An infusion rate of 3 µL/min was identified to result in the most repeatable nanoparticle distribution in PC3 tumours. Linear relationships have been obtained to first convert micro-CT greyscale values to HU values, then to local nanoparticle concentrations, and finally to nanoparticle-induced q(MNH) values. The total energy deposition rate in tumours was calculated and the observed similarity in total energy deposition rates in all three infusion rate groups suggests improvement in minimising nanoparticle leakage from the tumours. The results of this study demonstrate that micro-CT generated q(MNH) distribution and tumour physical models improve predicting capability of heat transfer simulation for designing reliable treatment protocols using magnetic nanoparticle hyperthermia.

  15. Long-term effects of continuous subcutaneous infusion versus daily subcutaneous injections of growth hormone (GH) on the insulin-like growth factor system, insulin sensitivity, body composition, and bone and lipoprotein metabolism in GH-deficient adults

    DEFF Research Database (Denmark)

    Laursen, Torben; Gravholt, Claus Højbjerg; Heickendorff, Lene

    2001-01-01

    injections (inj) in the evening as usual, and 7 received a continuous infusion (inf) of GH by means of a portable pump. The GH dose was kept unchanged before and during the study. Serum levels of insulin-like growth factor I (IGF-I) tended to increase in the patients switched to constant infusion (from 175...... for 6 months are comparable with respect to the IGF-IGFBP axis, whereas intermittent exposure may be of importance for the lipolytic effect of GH. The data on insulin sensitivity and lipoproteins suggest that constant GH exposure is as safe as intermittent GH administration....

  16. Hippocampal infusions of glucose reverse memory deficits produced by co-infusions of a GABA receptor agonist.

    Science.gov (United States)

    Krebs-Kraft, Desiree L; Parent, Marise B

    2008-02-01

    Although septal infusions of glucose typically have positive effects on memory, we have shown repeatedly that this treatment exacerbates memory deficits produced by co-infusions of gamma-aminobutyric acid (GABA) receptor agonists. The present experiments tested whether this negative interaction between glucose and GABA in the medial septum would be observed in the hippocampus, a brain region where glucose typically has positive effects on memory. Specifically, we determined whether hippocampal infusions of glucose would reverse or exacerbate memory deficits produced by hippocampal co-infusions of the GABA receptor agonist muscimol. Fifteen minutes prior to either assessing spontaneous alternation (SA) or continuous multiple trial inhibitory avoidance (CMIA) training, male Sprague-Dawley-derived rats were given bilateral hippocampal infusions of vehicle (phosphate-buffered saline [PBS], 1 microl/2 min), glucose (33 or 50 nmol), muscimol (0.3 or 0.4 microg, SA or 3 microg, CMIA) or muscimol and glucose combined in one solution. The results indicated that hippocampal infusions of muscimol alone decreased SA scores and CMIA retention latencies. More importantly, hippocampal infusions of glucose, at doses that had no effect when infused alone, attenuated (33 nmol) or reversed (50 nmol) the muscimol-induced memory deficits. Thus, although co-infusions of glucose with muscimol into the medial septum impair memory, the present findings show that an opposite effect is observed in the hippocampus. Collectively, these findings suggest that the memory-impairing interaction between glucose and GABA in the medial septum is not a general property of the brain, but rather is brain region-dependent.

  17. Volumetric CT-images improve testing of radiological image interpretation skills

    Energy Technology Data Exchange (ETDEWEB)

    Ravesloot, Cécile J., E-mail: C.J.Ravesloot@umcutrecht.nl [Radiology Department at University Medical Center Utrecht, Heidelberglaan 100, 3508 GA Utrecht, Room E01.132 (Netherlands); Schaaf, Marieke F. van der, E-mail: M.F.vanderSchaaf@uu.nl [Department of Pedagogical and Educational Sciences at Utrecht University, Heidelberglaan 1, 3584 CS Utrecht (Netherlands); Schaik, Jan P.J. van, E-mail: J.P.J.vanSchaik@umcutrecht.nl [Radiology Department at University Medical Center Utrecht, Heidelberglaan 100, 3508 GA Utrecht, Room E01.132 (Netherlands); Cate, Olle Th.J. ten, E-mail: T.J.tenCate@umcutrecht.nl [Center for Research and Development of Education at University Medical Center Utrecht, Heidelberglaan 100, 3508 GA Utrecht (Netherlands); Gijp, Anouk van der, E-mail: A.vanderGijp-2@umcutrecht.nl [Radiology Department at University Medical Center Utrecht, Heidelberglaan 100, 3508 GA Utrecht, Room E01.132 (Netherlands); Mol, Christian P., E-mail: C.Mol@umcutrecht.nl [Image Sciences Institute at University Medical Center Utrecht, Heidelberglaan 100, 3508 GA Utrecht (Netherlands); Vincken, Koen L., E-mail: K.Vincken@umcutrecht.nl [Image Sciences Institute at University Medical Center Utrecht, Heidelberglaan 100, 3508 GA Utrecht (Netherlands)

    2015-05-15

    Rationale and objectives: Current radiology practice increasingly involves interpretation of volumetric data sets. In contrast, most radiology tests still contain only 2D images. We introduced a new testing tool that allows for stack viewing of volumetric images in our undergraduate radiology program. We hypothesized that tests with volumetric CT-images enhance test quality, in comparison with traditional completely 2D image-based tests, because they might better reflect required skills for clinical practice. Materials and methods: Two groups of medical students (n = 139; n = 143), trained with 2D and volumetric CT-images, took a digital radiology test in two versions (A and B), each containing both 2D and volumetric CT-image questions. In a questionnaire, they were asked to comment on the representativeness for clinical practice, difficulty and user-friendliness of the test questions and testing program. Students’ test scores and reliabilities, measured with Cronbach's alpha, of 2D and volumetric CT-image tests were compared. Results: Estimated reliabilities (Cronbach's alphas) were higher for volumetric CT-image scores (version A: .51 and version B: .54), than for 2D CT-image scores (version A: .24 and version B: .37). Participants found volumetric CT-image tests more representative of clinical practice, and considered them to be less difficult than volumetric CT-image questions. However, in one version (A), volumetric CT-image scores (M 80.9, SD 14.8) were significantly lower than 2D CT-image scores (M 88.4, SD 10.4) (p < .001). The volumetric CT-image testing program was considered user-friendly. Conclusion: This study shows that volumetric image questions can be successfully integrated in students’ radiology testing. Results suggests that the inclusion of volumetric CT-images might improve the quality of radiology tests by positively impacting perceived representativeness for clinical practice and increasing reliability of the test.

  18. The Efficacy of Postoperative Wound Infusion with Bupivacaine for Pain Control after Cesarean Delivery: Randomized Double Blind Clinical Trial

    Directory of Open Access Journals (Sweden)

    Azin Alavi

    2007-06-01

    Full Text Available Objective: This study investigated the efficacy of bupivacaine wound infusion for pain control and opioid sparing effect after cesarean delivery.Materials and methods: We conducted a randomized double blind, placebo controlled clinical trial on 60 parturients undergoing cesarean section at a university hospital in Tehran. Patients were randomized to receive a pump infusion system that was filled with either 0.25% bupivacaine or equal volume of distilled water. A catheter was placed above the fascia and connected to electronic pump for 24 hours. Postoperative analog pain scores and morphine consumption were assessed at 6, 12 and 24 hours. Also time interval to first ambulation, length of hospitalization, complications and patient satisfaction were recorded. Data were analyzed using the SPSS software and P < 0.05 was considered statistically significant. Mann-Whitney u-test, student t-test and chi-square were used. Results: There were no differences in patient demographics and length of hospitalization and patient-generated resting pain scores between the two groups. Pain scores after coughing and leg raise during the first 6 postoperative hours were significantly less in the Bupivacaine group (P<0.001. The total dose of morphine consumption during the 24 hours study period was 2.5 ± 2.5 mg vs. 7.3 ± 2.7 mg for the bupivacaine and control groups, respectively (P<0.001. Compared with the control group, time to first ambulation was shorter in the bupivacaine group (11± 5h vs. 16 ± 4h (P< 0.01. Conclusion: Bupivacaine wound infusion was a simple and safe technique that provides effective analgesia and reduces morphine requirements after cesarean delivery.

  19. Pumping characteristics of sputter ion pump (SIP) and titanium sublimation pump (TSP) combination

    International Nuclear Information System (INIS)

    Ratnakala, K.C.; Patel, R.J.; Bhavsar, S.T.; Pandiyar, M.L.; Ramamurthi, S.S.

    1995-01-01

    For achieving hydrocarbon free, clean ultra high vacuum, SIP-TSP combination is one of the ideal choice for pumping. For the SRS facility in Centre for Advanced Technology (CAT), we are utilising this combination, enmass. For this purpose, two modules of these combination set-ups are assembled, one with the TSP as an integral part of SIP and the other, with TSP as a separate pump mounted on the top of SIP. The pump bodies were vacuum degassed at 700 degC at 10 -5 mbar for 3 hrs. An ultimate vacuum of 3 x 10 -11 mbar was achieved, after a bake-out at 250 degC for 4 hrs, followed by continuous SIP pumping for 48 hrs, with two TSP flashing at approximately 10 hrs interval. The pump-down patterns as well as the pressure-rise patterns are studied. (author). 2 refs., 5 figs

  20. Design of liquid lithium pumps for FMIT

    International Nuclear Information System (INIS)

    Adkins, H.E.

    1983-01-01

    In the Fusion Materials Irradiation Test (FMIT) facility, a jet of liquid lithium is bombarded by accelerated deuterons to generate high energy neutrons for materials testing. The lithium system will include two electromagnetic pumps, a 750 gpm main pump and a 10 gpm auxiliary pump. The larger pump was designed and built in 1982, following extensive testing of a similar pump in the Experimental Lithium System. Design of the auxiliary pump has been completed, but fabrication has not started. This paper discusses the design considerations leading to selection of the Annular Linear Induction Pump (ALIP) concept for these applications. Design parameters, fabrication procedures, and results of pump testing are also reviewed

  1. A One-Square-Millimeter Compact Hollow Structure for Microfluidic Pumping on an All-Glass Chip

    Directory of Open Access Journals (Sweden)

    Xing Yue (Larry Peng

    2016-04-01

    Full Text Available A micro surface tension pump is a new type of low-cost, built-in, all-glass, microfluidic pump on a glass microchip fabricated by one-step glass etching. However, geometric minimization and optimization for practical use are challenging. Here, we report a one-square-millimeter, built-in, all-glass pump controlled by two-way digital gas pressure. The pump consists simply of two joint chambers and a piston between two gas control channels. It does not require pre-perfusion for initialization, and can immediately begin to run when a liquid enters its inlet channel. It is also more reliable than conventional micro pumps for practical use due to its ability to restart after the formation of a blocking bubble, which can serve as a valuable troubleshooting procedure. Its volumetric pump output was 0.5–0.7 nL·s−1 under a pump head pressure of 300 Pa.

  2. The Tolerability and Efficacy of Rapid Infliximab Infusions in Patients with Inflammatory Bowel Disease.

    Science.gov (United States)

    Qazi, Taha; Shah, Bhavesh; El-Dib, Mohammed; Farraye, Francis A

    2016-02-01

    Few studies have assessed the loss of efficacy or patient and caregiver satisfaction with rapid infliximab infusions. The aim of this study is to assess the tolerability, loss of efficacy and to describe the impact on resource utilization and patient satisfaction in rapid infliximab infusions. Subjects with inflammatory bowel disease receiving rapid infliximab infusions were included in the study. Subjects received maintenance infusions from June 2011 to June 2013. Incidence of adverse reactions and the total number of rapid infliximab infusions were recorded. Efficacy was compared to published studies evaluating the long-term efficacy of infliximab infusions. Patient satisfaction was addressed through a survey following the implementation of the rapid infusion protocol. Seventy-five subjects with IBD were included in the study. Five hundred and twenty-two rapid infliximab infusions were provided to patients. There were no acute or delayed infusion reactions. Ten subjects (13 %) required either a dose escalation or interval adjustment between infliximab infusions. A majority of patients reported increased satisfaction with 1-h infliximab infusions, and 97 % of surveyed patients opted to continue rapid infusions. The rapid infliximab infusion protocol increased infusion unit efficiency by increasing capacity by 15 %. Cost savings in the elimination of nursing time translated to approximately $108,150 savings at our institution. Rapid infliximab infusions do not appear to increase the risk of loss of response compared to historical studies of long-term infliximab efficiency. A rapid infliximab infusion protocol improved efficiency in our infusion unit and increased patient and nursing satisfaction.

  3. Peristaltic pumps for waste disposal

    International Nuclear Information System (INIS)

    Griffith, G.W.

    1992-09-01

    Laboratory robots are capable of generating large volumes of hazardous liquid wastes when they are used to perform chemical analyses of metal finishing solutions. A robot at Allied-Signal Inc., Kansas City Division, generates 30 gallons of acid waste each month. This waste contains mineral acids, heavy metals, metal fluorides, and other materials. The waste must be contained in special drums that are closed to the atmosphere. The initial disposal method was to have the robot pour the waste into a collecting funnel, which contained a liquid-sensing valve to admit the waste into the drum. Spills were inevitable, splashing occurred, and the special valve often didn't work well. The device also occupied a large amount of premium bench space. Peristaltic pumps are made to handle hazardous liquids quickly and efficiently. A variable-speed pump, equipped with a quick-loading pump head, was mounted below the robot bench near the waste barrel. The pump inlet tube was mounted above the bench within easy reach of the robot, while the outlet tube was connected directly to the barrel. During operation, the robot brings the waste liquid up to the pump inlet tube and activates the pump. When the waste has been removed, the pump stops. The procedure is quick, simple, inexpensive, safe, and reliable

  4. Magnetohydrodynamic generator and pump system

    International Nuclear Information System (INIS)

    Birzvalk, Yu.A.; Karasev, B.G.; Lavrentyev, I.V.; Semikov, G.T.

    1983-01-01

    The MHD generator-pump system, or MHD coupling, is designed to pump liquid-metal coolant in the primary circuit of a fast reactor. It contains a number of generator and pump channels placed one after another and forming a single electrical circuit, but hydraulically connected parallel to the second and first circuits of the reactor. All the generator and pump channels are located in a magnetic field created by the magnetic system with an excitation winding that is fed by a regulated direct current. In 500 to 2000 MW reactors, the flow rate of the coolant in each loop of the primary circuit is 3 to 6 m 3 /s and the hydraulic power is 2 to 4 MW. This paper examines the primary characteristics of an MHD generator-pump system with various dimensions and number of channels, wall thicknesses, coolant flow rates, and magnetic fields. It is shown that its efficiency may reach 60 to 70%. The operating principle of the MHD generator-pump system is explained in the referenced patent and involves the transfer of hydraulic power from generator channels to pump channels using a magnetic field and electrical circuit common to both channels. Variations of this system may be analyzed using an equivalent circuit. 7 refs., 5 figs

  5. Electrostatic coupling of ion pumps.

    Science.gov (United States)

    Nieto-Frausto, J; Lüger, P; Apell, H J

    1992-01-01

    In this paper the electrostatic interactions between membrane-embedded ion-pumps and their consequences for the kinetics of pump-mediated transport processes have been examined. We show that the time course of an intrinsically monomolecular transport reaction can become distinctly nonexponential, if the reaction is associated with charge translocation and takes place in an aggregate of pump molecules. First we consider the electrostatic coupling of a single dimer of ion-pumps embedded in the membrane. Then we apply the treatment to the kinetic analysis of light-driven proton transport by bacteriorhodopsin which forms two-dimensional hexagonal lattices. Finally, for the case of nonordered molecules, we also consider a model in which the pumps are randomly distributed over the nodes of a lattice. Here the average distance is equal to that deduced experimentally and the elemental size of the lattice is the effective diameter of one single pump. This latter model is applied to an aggregate of membrane-embedded Na, K- and Ca-pumps. In all these cases the electrostatic potential considered is the exact solution calculated from the method of electrical images for a plane membrane of finite thickness immersed in an infinite aqueous solution environment. The distributions of charges (ions or charged binding sites) are considered homogeneous or discrete in the membrane and/or in the external solution. In the case of discrete distributions we compare the results from a mean field approximation and a stochastic simulation.

  6. Synoptic volumetric variations and flushing of the Tampa Bay estuary

    Science.gov (United States)

    Wilson, M.; Meyers, S. D.; Luther, M. E.

    2014-03-01

    Two types of analyses are used to investigate the synoptic wind-driven flushing of Tampa Bay in response to the El Niño-Southern Oscillation (ENSO) cycle from 1950 to 2007. Hourly sea level elevations from the St. Petersburg tide gauge, and wind speed and direction from three different sites around Tampa Bay are used for the study. The zonal (u) and meridional (v) wind components are rotated clockwise by 40° to obtain axial and co-axial components according to the layout of the bay. First, we use the subtidal observed water level as a proxy for mean tidal height to estimate the rate of volumetric bay outflow. Second, we use wavelet analysis to bandpass sea level and wind data in the time-frequency domain to isolate the synoptic sea level and surface wind variance. For both analyses the long-term monthly climatology is removed and we focus on the volumetric and wavelet variance anomalies. The overall correlation between the Oceanic Niño Index and volumetric analysis is small due to the seasonal dependence of the ENSO response. The mean monthly climatology between the synoptic wavelet variance of elevation and axial winds are in close agreement. During the winter, El Niño (La Niña) increases (decreases) the synoptic variability, but decreases (increases) it during the summer. The difference in winter El Niño/La Niña wavelet variances is about 20 % of the climatological value, meaning that ENSO can swing the synoptic flushing of the bay by 0.22 bay volumes per month. These changes in circulation associated with synoptic variability have the potential to impact mixing and transport within the bay.

  7. Agreement of mammographic measures of volumetric breast density to MRI.

    Directory of Open Access Journals (Sweden)

    Jeff Wang

    Full Text Available Clinical scores of mammographic breast density are highly subjective. Automated technologies for mammography exist to quantify breast density objectively, but the technique that most accurately measures the quantity of breast fibroglandular tissue is not known.To compare the agreement of three automated mammographic techniques for measuring volumetric breast density with a quantitative volumetric MRI-based technique in a screening population.Women were selected from the UCSF Medical Center screening population that had received both a screening MRI and digital mammogram within one year of each other, had Breast Imaging Reporting and Data System (BI-RADS assessments of normal or benign finding, and no history of breast cancer or surgery. Agreement was assessed of three mammographic techniques (Single-energy X-ray Absorptiometry [SXA], Quantra, and Volpara with MRI for percent fibroglandular tissue volume, absolute fibroglandular tissue volume, and total breast volume.Among 99 women, the automated mammographic density techniques were correlated with MRI measures with R(2 values ranging from 0.40 (log fibroglandular volume to 0.91 (total breast volume. Substantial agreement measured by kappa statistic was found between all percent fibroglandular tissue measures (0.72 to 0.63, but only moderate agreement for log fibroglandular volumes. The kappa statistics for all percent density measures were highest in the comparisons of the SXA and MRI results. The largest error source between MRI and the mammography techniques was found to be differences in measures of total breast volume.Automated volumetric fibroglandular tissue measures from screening digital mammograms were in substantial agreement with MRI and if associated with breast cancer could be used in clinical practice to enhance risk assessment and prevention.

  8. Agreement of mammographic measures of volumetric breast density to MRI.

    Science.gov (United States)

    Wang, Jeff; Azziz, Ania; Fan, Bo; Malkov, Serghei; Klifa, Catherine; Newitt, David; Yitta, Silaja; Hylton, Nola; Kerlikowske, Karla; Shepherd, John A

    2013-01-01

    Clinical scores of mammographic breast density are highly subjective. Automated technologies for mammography exist to quantify breast density objectively, but the technique that most accurately measures the quantity of breast fibroglandular tissue is not known. To compare the agreement of three automated mammographic techniques for measuring volumetric breast density with a quantitative volumetric MRI-based technique in a screening population. Women were selected from the UCSF Medical Center screening population that had received both a screening MRI and digital mammogram within one year of each other, had Breast Imaging Reporting and Data System (BI-RADS) assessments of normal or benign finding, and no history of breast cancer or surgery. Agreement was assessed of three mammographic techniques (Single-energy X-ray Absorptiometry [SXA], Quantra, and Volpara) with MRI for percent fibroglandular tissue volume, absolute fibroglandular tissue volume, and total breast volume. Among 99 women, the automated mammographic density techniques were correlated with MRI measures with R(2) values ranging from 0.40 (log fibroglandular volume) to 0.91 (total breast volume). Substantial agreement measured by kappa statistic was found between all percent fibroglandular tissue measures (0.72 to 0.63), but only moderate agreement for log fibroglandular volumes. The kappa statistics for all percent density measures were highest in the comparisons of the SXA and MRI results. The largest error source between MRI and the mammography techniques was found to be differences in measures of total breast volume. Automated volumetric fibroglandular tissue measures from screening digital mammograms were in substantial agreement with MRI and if associated with breast cancer could be used in clinical practice to enhance risk assessment and prevention.

  9. Method for Determining Volumetric Efficiency and Its Experimental Validation

    Directory of Open Access Journals (Sweden)

    Ambrozik Andrzej

    2017-12-01

    Full Text Available Modern means of transport are basically powered by piston internal combustion engines. Increasingly rigorous demands are placed on IC engines in order to minimise the detrimental impact they have on the natural environment. That stimulates the development of research on piston internal combustion engines. The research involves experimental and theoretical investigations carried out using computer technologies. While being filled, the cylinder is considered to be an open thermodynamic system, in which non-stationary processes occur. To make calculations of thermodynamic parameters of the engine operating cycle, based on the comparison of cycles, it is necessary to know the mean constant value of cylinder pressure throughout this process. Because of the character of in-cylinder pressure pattern and difficulties in pressure experimental determination, in the present paper, a novel method for the determination of this quantity was presented. In the new approach, the iteration method was used. In the method developed for determining the volumetric efficiency, the following equations were employed: the law of conservation of the amount of substance, the first law of thermodynamics for open system, dependences for changes in the cylinder volume vs. the crankshaft rotation angle, and the state equation. The results of calculations performed with this method were validated by means of experimental investigations carried out for a selected engine at the engine test bench. A satisfactory congruence of computational and experimental results as regards determining the volumetric efficiency was obtained. The method for determining the volumetric efficiency presented in the paper can be used to investigate the processes taking place in the cylinder of an IC engine.

  10. Extended Kalman filtering for continuous volumetric MR-temperature imaging.

    Science.gov (United States)

    Denis de Senneville, Baudouin; Roujol, Sébastien; Hey, Silke; Moonen, Chrit; Ries, Mario

    2013-04-01

    Real time magnetic resonance (MR) thermometry has evolved into the method of choice for the guidance of high-intensity focused ultrasound (HIFU) interventions. For this role, MR-thermometry should preferably have a high temporal and spatial resolution and allow observing the temperature over the entire targeted area and its vicinity with a high accuracy. In addition, the precision of real time MR-thermometry for therapy guidance is generally limited by the available signal-to-noise ratio (SNR) and the influence of physiological noise. MR-guided HIFU would benefit of the large coverage volumetric temperature maps, including characterization of volumetric heating trajectories as well as near- and far-field heating. In this paper, continuous volumetric MR-temperature monitoring was obtained as follows. The targeted area was continuously scanned during the heating process by a multi-slice sequence. Measured data and a priori knowledge of 3-D data derived from a forecast based on a physical model were combined using an extended Kalman filter (EKF). The proposed reconstruction improved the temperature measurement resolution and precision while maintaining guaranteed output accuracy. The method was evaluated experimentally ex vivo on a phantom, and in vivo on a porcine kidney, using HIFU heating. On the in vivo experiment, it allowed the reconstruction from a spatio-temporally under-sampled data set (with an update rate for each voxel of 1.143 s) to a 3-D dataset covering a field of view of 142.5×285×54 mm(3) with a voxel size of 3×3×6 mm(3) and a temporal resolution of 0.127 s. The method also provided noise reduction, while having a minimal impact on accuracy and latency.

  11. A new infusion pathway monitoring system utilizing electrostatic induced potential.

    Science.gov (United States)

    Maki, Hiromichi; Yonezawa, Yoshiharu; Ogawa, Hidekuni; Ninomiya, Ishio; Sada, Kouji; Hamada, Shingo; Hahn, Alien W; Caldwell, W Morton

    2006-01-01

    We have developed a new infusion pathway monitoring system employing linear integrated circuits and a low-power 8-bit single chip microcomputer. The system is available for hospital and home use and it constantly monitors the intactness of the pathway. The sensor is an electro-conductive polymer electrode wrapped around the infusion polyvinyl chloride infusion tube. This records an AC (alternating current) voltage induced on the patient's body by electrostatic coupling from the normal 100 volt, 60 Hz AC power line wiring field in the patient's room. If the injection needle or infusion tube becomes detached, then the system detects changes in the induced AC voltage and alerts the nursing station, via the nurse call system or PHS (personal handy phone System).

  12. Effects of dexmedetomidine infusion during spinal anesthesia on ...

    African Journals Online (AJOL)

    Ebru Tarıkçı Kılıç

    2018-02-19

    Feb 19, 2018 ... administered in cases with high scores on the visual analog scale. ... dexmedetomidine infusion had a hemodynamic depressant effect intraoperatively whereas it had no ..... ety depresses the relevant centers in the brain and.

  13. Resin Infusion Rigidized Inflatable Concept Development and Demonstration

    Data.gov (United States)

    National Aeronautics and Space Administration — A novel concept utilizing resin infusion to rigidize inflatable structures was developed at JSC ES. This ICA project intends to complete manufacturing of a prototype...

  14. Infusing Social Responsibility into the Curriculum and Cocurriculum: Campus Examples

    Science.gov (United States)

    Reason, Robert D.

    2013-01-01

    This chapter highlights good practices and lessons learned for infusing social responsibility--contributing to the larger community and taking seriously the perspectives of others--as outcomes of college.

  15. Vacuum Infusion of Low-Cost Aerospce Composites

    National Research Council Canada - National Science Library

    Labordus, Maarten

    2002-01-01

    This report results from a contract tasking TNO Industrie as follows: A mold system will be designed in which the hydrostatic pressure can be measured in the resin during the vacuum infusion process...

  16. Attribute based selection of thermoplastic resin for vacuum infusion process

    DEFF Research Database (Denmark)

    Prabhakaran, R.T. Durai; Lystrup, Aage; Løgstrup Andersen, Tom

    2011-01-01

    The composite industry looks toward a new material system (resins) based on thermoplastic polymers for the vacuum infusion process, similar to the infusion process using thermosetting polymers. A large number of thermoplastics are available in the market with a variety of properties suitable...... for different engineering applications, and few of those are available in a not yet polymerised form suitable for resin infusion. The proper selection of a new resin system among these thermoplastic polymers is a concern for manufactures in the current scenario and a special mathematical tool would...... be beneficial. In this paper, the authors introduce a new decision making tool for resin selection based on significant attributes. This article provides a broad overview of suitable thermoplastic material systems for vacuum infusion process available in today’s market. An illustrative example—resin selection...

  17. Osmotic Drying and Nutrient Infusion of Fruits and Vegetables

    National Research Council Canada - National Science Library

    Cohen, Joseph

    1999-01-01

    .... Initially, six commercial fruit products were chosen for long-term storage. Two representative products, mango-flavored apple cubes and cherries, were then prepared with infused vitamins and minerals...

  18. Synthesis of Volumetric Ring Antenna Array for Terrestrial Coverage Pattern

    Directory of Open Access Journals (Sweden)

    Alberto Reyna

    2014-01-01

    Full Text Available This paper presents a synthesis of a volumetric ring antenna array for a terrestrial coverage pattern. This synthesis regards the spacing among the rings on the planes X-Y, the positions of the rings on the plane X-Z, and uniform and concentric excitations. The optimization is carried out by implementing the particle swarm optimization. The synthesis is compared with previous designs by resulting with proper performance of this geometry to provide an accurate coverage to be applied in satellite applications with a maximum reduction of the antenna hardware as well as the side lobe level reduction.

  19. Synthesis of Volumetric Ring Antenna Array for Terrestrial Coverage Pattern

    Science.gov (United States)

    Reyna, Alberto; Panduro, Marco A.; Del Rio Bocio, Carlos

    2014-01-01

    This paper presents a synthesis of a volumetric ring antenna array for a terrestrial coverage pattern. This synthesis regards the spacing among the rings on the planes X-Y, the positions of the rings on the plane X-Z, and uniform and concentric excitations. The optimization is carried out by implementing the particle swarm optimization. The synthesis is compared with previous designs by resulting with proper performance of this geometry to provide an accurate coverage to be applied in satellite applications with a maximum reduction of the antenna hardware as well as the side lobe level reduction. PMID:24701150

  20. Volumetric and calorimetric properties of aqueous ionene solutions.

    Science.gov (United States)

    Lukšič, Miha; Hribar-Lee, Barbara

    2017-02-01

    The volumetric (partial and apparent molar volumes) and calorimetric properties (apparent heat capacities) of aqueous cationic polyelectrolyte solutions - ionenes - were studied using the oscillating tube densitometer and differential scanning calorimeter. The polyion's charge density and the counterion properties were considered as variables. The special attention was put to evaluate the contribution of electrostatic and hydrophobic effects to the properties studied. The contribution of the CH 2 group of the polyion's backbone to molar volumes and heat capacities was estimated. Synergistic effect between polyion and counterions was found.