WorldWideScience

Sample records for volumetric body-force displacements

  1. Mathematical Model Defining Volumetric Losses of Hydraulic Oil Compression in a Variable Capacity Displacement Pump

    Directory of Open Access Journals (Sweden)

    Paszota Zygmunt

    2015-01-01

    Full Text Available The objective of the work is to develop the capability of evaluating the volumetric losses of hydraulic oil compression in the working chambers of high pressure variable capacity displacement pump. Volumetric losses of oil compression must be determined as functions of the same parameters, which the volumetric losses due to leakage, resulting from the quality of design solution of the pump, are evaluated as dependent on and also as function of the oil aeration coefficient Ɛ. A mathematical model has been developed describing the hydraulic oil compressibility coefficient klc|Δppi;Ɛ;v as a relation to the ratio ΔpPi/pn of indicated increase ΔpPi of pressure in the working chambers and the nominal pressure pn, to the pump capacity coefficient bP, to the oil aeration coefficient  and to the ratio v/vnof oil viscosity v and reference viscosity vn. A mathematical model is presented of volumetric losses qpvc|ΔpPi;bp;;vof hydraulic oil compression in the pump working chambers in the form allowing to use it in the model of power of losses and energy efficiency

  2. Effect of the working liquid compressibility on the picture of volumetric and mechanical losses in a high pressure displacement pump used in a hydrostatic drive

    National Research Council Canada - National Science Library

    Paszota, Zygmunt

    2012-01-01

    Working liquid compressibility may considerably change the values and proportions of coefficients of volumetric and mechanical energy losses in the displacement pump used in a hydrostatic drive system...

  3. Dependence of displacement-length scaling relations for fractures and deformation bands on the volumetric changes across them

    Science.gov (United States)

    Schultz, R.A.; Soliva, R.; Fossen, H.; Okubo, C.H.; Reeves, D.M.

    2008-01-01

    Displacement-length data from faults, joints, veins, igneous dikes, shear deformation bands, and compaction bands define two groups. The first group, having a power-law scaling relation with a slope of n = 1 and therefore a linear dependence of maximum displacement and discontinuity length (Dmax = ??L), comprises faults and shear (non-compactional or non-dilational) deformation bands. These shearing-mode structures, having shearing strains that predominate over volumetric strains across them, grow under conditions of constant driving stress, with the magnitude of near-tip stress on the same order as the rock's yield strength in shear. The second group, having a power-law scaling relation with a slope of n = 0.5 and therefore a dependence of maximum displacement on the square root of discontinuity length (Dmax = ??L0.5), comprises joints, veins, igneous dikes, cataclastic deformation bands, and compaction bands. These opening- and closing-mode structures grow under conditions of constant fracture toughness, implying significant amplification of near-tip stress within a zone of small-scale yielding at the discontinuity tip. Volumetric changes accommodated by grain fragmentation, and thus control of propagation by the rock's fracture toughness, are associated with scaling of predominantly dilational and compactional structures with an exponent of n = 0.5. ?? 2008 Elsevier Ltd.

  4. Volumetric Displacement Effects In Euler-Lagrange Simulations of Sediment-Laden Oscillatory Flows

    Science.gov (United States)

    Apte, S.; Finn, J. R.; Cihonski, A.

    2013-12-01

    An improved, three-dimensional approach for Euler-Lagrange simulation of sediment-laden oscillatory turbulent flows is developed. In this approach, the sediment particles are unresolved and subgrid similar to a discrete element model (DEM), however, the fluid volume (mass) displaced by the particle is accounted for in the conservation equations. Recent Euler-Lagrange modeling of a few microbubbles entrained in a traveling vortex ring (Cihonski et al., JFM, 2013) has shown that extension of the standard point-particle DEM method to include local volume displacement effects is critical in capturing vortex distortion effects due to microbubbles, even in a very dilute suspension. We extend this approach to investigate particle-laden oscillatory boundary layers representative of coastal sediment environments. A wall bounded, doubly periodic domain is considered laden with a layer of sediment particles in laminar as well as turbulent oscillatory boundary layers corresponding to the experiments of Keiller and Sleath (1987) and Jensen et al. (1987). Inter-particle and particle-wall collisions are modeled using a soft-sphere model which uses a nested collision grid to minimize computational effort. The effects of fluid mass displaced by the particles on the flow statistics are quantified by comparing a standard two-way coupling approach (without volume displacement effects) with volume displacement effects to show that the latter models are important for cases with low specific gravity.

  5. Incorporating Volumetric Displacement Effects In Euler-Lagrange Simulations of Particle-Laden Oscillatory Flows

    Science.gov (United States)

    Apte, Sourabh; Finn, Justin; Cihonski, Andrew

    2013-11-01

    Recent Euler-Lagrange discrete element modeling of a few microbubbles entrained in a traveling vortex ring (Cihonski et al., JFM, 2013) has shown that extension of the point-particle method to include local volume displacement effects is critical for capturing vortex distortion effects due to microbubbles, even in a very dilute suspension. We extend this approach to investigate particle-laden oscillatory boundary layers representative of coastal sediment environments. A wall bounded, doubly periodic domain is considered laden with a layer of sediment particles in laminar as well as turbulent oscillatory boundary layers corresponding to the experiments of Keiller and Sleath (1987) and Jensen et al. (1987). Inter-particle and particle-wall collisions are modeled using a soft-sphere model which uses a nested collision grid to minimize computational effort. The effects of fluid mass displaced by the particles on the flow statistics are quantified by comparing a standard two-way coupling approach (without volume displacement effects) with volume displacement effects to show that the latter models are important for low cases with low particle-fluid density ratios. NSF project #1133363, Sediment-Bed-Turbulence Coupling in Oscillatory Flows. EPSRC Project # EP/J00507X/1, EP/J005541/1 Sand Transport under Irregular and Breaking Waves Conditions (SINBAD).

  6. Analysis of Temperature's Influence on a Digital Displacement Pump's Volumetric Efficiency

    DEFF Research Database (Denmark)

    Pedersen, Henrik C.; Johansen, Per; Yigen, Cemre;

    2012-01-01

    The focus of the current paper is on a small 18 cm3/rev Digital Displacement Pump (DDP), where it is investigated how temperature influency the pump behaviour and static performance. An experimentally validated model of the DDP is presented, which is the basis for the investigation. From the resu...

  7. Standardization of a Volumetric Displacement Measurement for Two-Body Abrasion Scratch Test Data Analysis

    Science.gov (United States)

    Street, K. W. Jr.; Kobrick, R. L.; Klaus, D. M.

    2011-01-01

    A limitation has been identified in the existing test standards used for making controlled, two-body abrasion scratch measurements based solely on the width of the resultant score on the surface of the material. A new, more robust method is proposed for analyzing a surface scratch that takes into account the full three-dimensional profile of the displaced material. To accomplish this, a set of four volume- displacement metrics was systematically defined by normalizing the overall surface profile to denote statistically the area of relevance, termed the Zone of Interaction. From this baseline, depth of the trough and height of the plowed material are factored into the overall deformation assessment. Proof-of-concept data were collected and analyzed to demonstrate the performance of this proposed methodology. This technique takes advantage of advanced imaging capabilities that allow resolution of the scratched surface to be quantified in greater detail than was previously achievable. When reviewing existing data analysis techniques for conducting two-body abrasive scratch tests, it was found that the ASTM International Standard G 171 specified a generic metric based only on visually determined scratch width as a way to compare abraded materials. A limitation to this method was identified in that the scratch width is based on optical surface measurements, manually defined by approximating the boundaries, but does not consider the three-dimensional volume of material that was displaced. With large, potentially irregular deformations occurring on softer materials, it becomes unclear where to systematically determine the scratch width. Specifically, surface scratches on different samples may look the same from a top view, resulting in an identical scratch width measurement, but may vary in actual penetration depth and/or plowing deformation. Therefore, two different scratch profiles would be measured as having identical abrasion properties, although they differ

  8. Transient and residual stresses and displacements in self-curing bone cement - Part I: characterization of relevant volumetric behavior of bone cement.

    Science.gov (United States)

    Ahmed, A M; Pak, W; Burke, D L; Miller, J

    1982-02-01

    In this first part of a two-part report, some aspects of the volumetric behavior of bone cement during its curing process are examined as a prelude to an analysis for the transient and residual stresses and displacements in stem fixation systems. Experiments show that stress generation in the cement is associated with its temperature while curing and that during the cooling phase, the stresses are mainly due to thermal as opposed to bulk shrinkage. The appropriate coefficient of thermal expansion of bone cement has been evaluated from measurements in a simulated fixation system in conjuction with a thermoelastic analysis.

  9. Accurate recovery of 4D left ventricular deformations using volumetric B-splines incorporating phase based displacement estimates

    Science.gov (United States)

    Chen, Jian; Tustison, Nicholas J.; Amini, Amir A.

    2006-03-01

    In this paper, an improved framework for estimation of 3-D left-ventricular deformations from tagged MRI is presented. Contiguous short- and long-axis tagged MR images are collected and are used within a 4-D B-Spline based deformable model to determine 4-D displacements and strains. An initial 4-D B-spline model fitted to sparse tag line data is first constructed by minimizing a 4-D Chamfer distance potential-based energy function for aligning isoparametric planes of the model with tag line locations; subsequently, dense virtual tag lines based on 2-D phase-based displacement estimates and the initial model are created. A final 4-D B-spline model with increased knots is fitted to the virtual tag lines. From the final model, we can extract accurate 3-D myocardial deformation fields and corresponding strain maps which are local measures of non-rigid deformation. Lagrangian strains in simulated data are derived which show improvement over our previous work. The method is also applied to 3-D tagged MRI data collected in a canine.

  10. Fluid Flows driven by Oscillating Body Force

    CERN Document Server

    Vladimirov, V A

    2016-01-01

    In this note we consider general formulation of Euler's equations for an inviscid incompressible homogeneous fluid with an oscillating body force. Our aim is to derive the averaged equations for these flows with the help of two-timing method. Our main result is the general and simple form of the equation describing the averaged flows, which are derived without making any additional assumptions. The presented results can have many interesting applications.

  11. 136Sn and three-body forces

    Indian Academy of Sciences (India)

    M Saha Sarkar; S Sarkar

    2015-09-01

    New experimental data on 2+ energies of 136,138Sn confirm the trend of lower 2+ excitation energies of even–even tin isotopes with > 82 compared to those with N < 82. However, none of the theoretical predictions using both realistic and empirical interactions can reproduce experimental data on excitation energies as well as the transition probabilities ((2; 6+ → 4+)) of these nuclei, simultaneously, apart from the ones whose matrix elements have been changed empirically to produce mixed seniority states by weakening the pairing. We have shown that the experimental result also shows good agreement with the theory in which three-body forces have been included in a realistic interaction. The new theoretical results on transition probabilities are discussed to identify the experimental quantities which will clearly distinguish between different views.

  12. Some Three-body force cancellations in Chiral Lagrangians

    CERN Document Server

    Arriola, E Ruiz

    2016-01-01

    The cancellation between off-shell two body forces and three body forces implies a tremendous simplification in the study of three body resonances in two meson-one baryon systems. While this can be done by means of Faddeev equations we provide an alternative and simpler derivation using just the chiral Lagrangian and the field re-parametrization invariance.

  13. EXTERNAL BODY FORCE IN FINITE DIFFERENCE LATTICE BOLTZMANN METHOD

    Institute of Scientific and Technical Information of China (English)

    CHEN Sheng; LIU Zhao-hui; SHI Bao-chang; ZHENG Chu-guang

    2005-01-01

    A new finite difference lattice Boltzmann scheme is developed. Because of analyzing the influence of external body force roundly, the correct Navier-Stokes equations with the external body force are recovered, without any additional unphysical terms. And some numerical results are presented. The result which close agreement with analytical data shows the good performance of the model.

  14. Thermodynamic properties of nuclear matter with three-body forces

    Science.gov (United States)

    Somà, V.; Bożek, P.

    2009-08-01

    We calculate thermodynamic quantities in symmetric nuclear matter within the self-consistent Green's functions method including three-body forces. The thermodynamic potential is computed directly from a diagrammatic expansion, implemented with the CD-Bonn and Nijmegen nucleon-nucleon potentials and the Urbana three-body forces. We present results for entropy and pressure up to temperatures of 20 MeV and densities of 0.32fm-3. While the pressure is sensitive to the inclusion of three-body forces, the entropy is not. The unstable spinodal region is identified and the critical temperature associated to the liquid-gas phase transition is determined. When three-body forces are added we find a strong reduction of the critical temperature, obtaining Tc≃12MeV.

  15. Thermodynamic properties of nuclear matter with three-body forces

    CERN Document Server

    Soma, V

    2009-01-01

    We calculate thermodynamic quantities in symmetric nuclear matter within the self-consistent Green's functions method including three-body forces. The thermodynamic potential is computed directly from a diagrammatic expansion, implemented with the CD-Bonn and Nijmegen nucleon-nucleon potentials and the Urbana three-body forces. We present results for entropy and pressure up to temperatures of 20 MeV and densities of 0.32 fm^-3. While the pressure is sensitive to the inclusion of three-body forces, the entropy is not. The unstable spinodal region is identified and the critical temperature associated to the liquid-gas phase transition is determined. When three-body forces are added we find a strong reduction of the critical temperature, obtaining T_c ~ 12 MeV.

  16. Accurate assessment of breast volume: a study comparing the volumetric gold standard (direct water displacement measurement of mastectomy specimen) with a 3D laser scanning technique.

    Science.gov (United States)

    Yip, Jia Miin; Mouratova, Naila; Jeffery, Rebecca M; Veitch, Daisy E; Woodman, Richard J; Dean, Nicola R

    2012-02-01

    Preoperative assessment of breast volume could contribute significantly to the planning of breast-related procedures. The availability of 3D scanning technology provides us with an innovative method for doing this. We performed this study to compare measurements by this technology with breast volume measurement by water displacement. A total of 30 patients undergoing 39 mastectomies were recruited from our center. The volume of each patient's breast(s) was determined with a preoperative 3D laser scan. The volume of the mastectomy specimen was then measured in the operating theater by water displacement. There was a strong linear association between breast volumes measured using the 2 different methods when using a Pearson correlation (r = 0.95, P Scanner as a tool for assessment of breast volume.

  17. Gravitational body forces focus North American intraplate earthquakes

    Science.gov (United States)

    Levandowski, William Brower; Zellman, Mark; Briggs, Richard

    2017-01-01

    Earthquakes far from tectonic plate boundaries generally exploit ancient faults, but not all intraplate faults are equally active. The North American Great Plains exemplify such intraplate earthquake localization, with both natural and induced seismicity generally clustered in discrete zones. Here we use seismic velocity, gravity and topography to generate a 3D lithospheric density model of the region; subsequent finite-element modelling shows that seismicity focuses in regions of high-gravity-derived deviatoric stress. Furthermore, predicted principal stress directions generally align with those observed independently in earthquake moment tensors and borehole breakouts. Body forces therefore appear to control the state of stress and thus the location and style of intraplate earthquakes in the central United States with no influence from mantle convection or crustal weakness necessary. These results show that mapping where gravitational body forces encourage seismicity is crucial to understanding and appraising intraplate seismic hazard.

  18. Gravitational body forces focus North American intraplate earthquakes

    Science.gov (United States)

    Levandowski, Will; Zellman, Mark; Briggs, Rich

    2017-02-01

    Earthquakes far from tectonic plate boundaries generally exploit ancient faults, but not all intraplate faults are equally active. The North American Great Plains exemplify such intraplate earthquake localization, with both natural and induced seismicity generally clustered in discrete zones. Here we use seismic velocity, gravity and topography to generate a 3D lithospheric density model of the region; subsequent finite-element modelling shows that seismicity focuses in regions of high-gravity-derived deviatoric stress. Furthermore, predicted principal stress directions generally align with those observed independently in earthquake moment tensors and borehole breakouts. Body forces therefore appear to control the state of stress and thus the location and style of intraplate earthquakes in the central United States with no influence from mantle convection or crustal weakness necessary. These results show that mapping where gravitational body forces encourage seismicity is crucial to understanding and appraising intraplate seismic hazard.

  19. Naive Dimensional Analysis for Three-Body Forces Without Pions

    CERN Document Server

    Griesshammer, H W

    2005-01-01

    For systems of three identical particles in which short-range forces produce shallow two-particle bound states, and in particular for the ``pion-less'' Effective Field Theory of Nuclear Physics, I extend and systematise the power-counting of three-body forces to all partial-waves and orders, including external currents. With low-energy observables independent of the details of short-distance dynamics, the typical strength of a three-body force is determined from the superficial degree of divergence of the three-body diagrams which contain only two-body forces. This na\\"ive dimensional analysis must be amended as the asymptotic solution to the leading-order Faddeev equation depends for large off-shell momenta crucially on the partial wave and spin-combination of the system. It is shown by analytic construction to be weaker in most channels with angular momentum smaller than 3 than expected. This demotes many three-nucleon forces to high orders. Observables like the quartet-S-scattering length are less sensitiv...

  20. Optimal plane changes using third-body forces.

    Science.gov (United States)

    Villac, B F; Scheeres, D J

    2004-05-01

    The fuel optimality of third-body driven plane changes (i.e., plane changes performed by using third-body forces) over one-impulse transfers is investigated numerically and analytically. In particular, the range of third-body driven plane changes that are realizable is shown to be restricted and one impulse must be used in the uncovered regions. However, when third-body driven plane changes are realizable, it is shown that they are always optimal above a certain critical value (about 40 degrees ) that depends on the initial condition. Contour plots of optimal DeltaV values to perform a desired plane changes are given.

  1. Sustaining processes from recurrent flows in body-forced turbulence

    CERN Document Server

    Lucas, Dan

    2016-01-01

    By extracting unstable invariant solutions directly from body-forced three-dimensional turbulence, we study the dynamical processes at play when the forcing is large scale and either unidirectional in the momentum or the vorticity equations. In the former case, the dynamical processes familiar from recent work on linearly-stable shear flows - variously called the Self-Sustaining Process (Waleffe 1997) or Vortex-Wave Interaction (Hall & Smith 1991; Hall & Sherwin 2010) - are important even when the base flow is linearly unstable. In the latter case, where the forcing drives Taylor-Green vortices, a number of mechanisms are observed from the various types of periodic orbits isolated. In particular, two different transient growth mechanisms are discussed to explain the more complex states found.

  2. Investigation of many-body forces in krypton and xenon

    Science.gov (United States)

    Salacuse, J. J.; Egelstaff, P. A.

    1988-10-01

    The simplicity of the state dependence at relatively high temperatures of the many-body potential contribution to the pressure and energy has been pointed out previously [J. Ram and P. A. Egelstaff, J. Phys. Chem. Liq. 14, 29 (1984); A. Teitsima and P. A. Egelstaff, Phys. Rev. A 21, 367 (1980)]. In this paper, we investigate how far these many-body potential terms may be represented by simple models in the case of krypton on the 423-, 273-, 190-, and 150-K isotherms, and xenon on the 170-, 210-, and 270-K isotherms. At the higher temperatures the best agreement is found for the mean-field type of theory, and some consequences are pointed out. On the lower isotherms a state point is found where the many-body energy vanishes, and large departures from mean-field behavior are observed. This is attributed to the influence of short-ranged many-body forces.

  3. Morphology and Dynamics of Lithospheric Body Force Instabilities: Sheets, Drips and In-Between

    Science.gov (United States)

    Beall, A.; Moresi, L. N.

    2014-12-01

    Foundering of the Earth's lithosphere, and consequent energy and mass flux across the upper boundary layer and mantle interface, is driven locally by gravitational body forces. The related instabilities are usually classified as having sheet-like or drip-like morphologies. The former is associated with whole lithosphere (subduction) or delamination type foundering such as suggested for beneath the southern Sierra-Nevada and the Colorado Plateau, the latter to classic Rayleigh-Taylor instability below an upper layer, suggested to have occurred beneath the Tibetan Plateau and North Island, New Zealand. This dichotomy is non-trivial; classification of phenomena into one or the other is often debated and is difficult to infer from observables. The two morphologies are most likely end-members. Here I refine the dynamics driving morphology selection as a function of rheological lamination and boundary layer Rayleigh number in 2D and 3D, using the finite-element particle-in-cell code Underworld. I explore the influence of morphology on mass flux, topography and crustal deformation as well as deviation from classic 2D scalings. Additionally, tectonic displacement interference with instability development is discussed using basic 3D shear-box style models. By quantifying and describing the theoretical instability dynamics which could result in a plausible range of morphological expressions, I aim to build a general framework which can be paired to the discussion involving firstly, the recognition of varied styles of body force instabilities in the modern Earth and rock record and secondly, to what degree pattern selection impacts boundary layer mass and energy flux.

  4. A Highly Resolved Large-Eddy Simulation of a Wind Turbine using an Actuator Line Model with Optimal Body Force Projection

    Science.gov (United States)

    Martínez-Tossas, Luis A.; Churchfield, Matthew J.; Meneveau, Charles

    2016-09-01

    When representing the blade aerodynamics with rotating actuator lines, the computed forces have to be projected back to the CFD flow field as a volumetric body force. That has been done in the past with a geometrically simple uniform three-dimensional Gaussian at each point along the blade. We argue that the body force can be shaped in a way that better predicts the blade local flow field, the blade load distribution, and the formation of the tip/root vortices. In previous work, we have determined the optimal scales of circular and elliptical Gaussian kernels that best reproduce the local flow field in two-dimensions. In this work we extend the analysis and applications by considering the full three-dimensional blade to test our hypothesis in a highly resolved Large Eddy Simulation.

  5. Many-body forces, isospin asymmetry and dense hyperonic matter

    CERN Document Server

    Gomes, R O; Schramm, S; Vascconcellos, C A Z

    2015-01-01

    The equation of state (EoS) of asymmetric nuclear matter at high densities is a key topic for the description of matter inside neutron stars. The determination of the properties of asymmetric nuclear matter, such as the symmetry energy ($a_{sym}$) and the slope of the symmetry energy ($L_0$) at saturation density, has been exaustively studied in order to better constrain the nuclear matter EoS. However, differently from symmetric matter properties that are reasonably constrained, the symmetry energy and its slope still large uncertainties in their experimental values. Regarding this subject, some studies point towards small values of the slope of the symmetry energy, while others suggest rather higher values. Such a lack of agreement raised a certain debate in the scientific community. In this paper, we aim to analyse the role of these properties on the behavior of asymmetric hyperonic matter. Using the formalism presented in Ref. (R.O. Gomes et al 2014}, which considers many-body forces contributions in the ...

  6. Manifestation of three-body forces in f7/2-shell nuclei

    CERN Document Server

    Volya, Alexander

    2008-01-01

    The traditional nuclear shell model approach is extended to include many-body forces. The empirical Hamiltonian with a three-body force is constructed for the proton and neutron 0f7/2 shells. Manifestations of the three-body force in spectra, binding energies, seniority mixing, particle-hole symmetry, electromagnetic and particle transition rates are investigated. The model with a three-body force is demonstrated to provide a better agreement with observations as compared to large-scale traditional shell model calculations.

  7. The body force in a three-dimensional Lame system identification and regularization

    DEFF Research Database (Denmark)

    Trong, Dang Duc; Phan, Thanh Nam; Thuc, Phung Trong

    2012-01-01

    Let a three-dimensional isotropic elastic body be described by the Lamé system with the body force of the form F(x, t) = (t)f (x), where is known. We consider the problem of determining the unknown spatial term f (x) of the body force when the surface stress history is given as the overdeterminat...

  8. Effects of Microscopic Three-body Forces in Asymmetric Nuclear Matter

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    The efiects of microscopic three-body forces on the equatioil of state(EOS)and the single particle properties of isospin asymmetric nuclear matter have been studied within Brueckner-Hartree-Fock framework~[1]The microscopic three-body force model constructed from meson exchange current approach in Ref.~[2] has been extended to isospin asymmetric nuclear matter

  9. Numerical Implementation of Three-Body Forces in Bound State Faddeev Calculations in Three Dimensions

    CERN Document Server

    Liu, H; Glöckle, W; Elster, Ch.

    2002-01-01

    The Faddeev equations for the three-body bound state are solved directly as thre e-dimensional integral equations without employing partial wave decomposition. Two-body forces of the Malfliet-Tjon type and simple spin independent genuine three-body forces are considered for the calculation of the three-body binding energy.

  10. DUAL RECIPROCITY HYBRID BOUNDARY NODE METHOD FOR THREE-DIMENSIONAL ELASTICITY WITH BODY FORCE

    Institute of Scientific and Technical Information of China (English)

    Fei Yan; Yuanhan Wang; Yu Miao; Fei Tan

    2008-01-01

    Combining Dual Reciprocity Method (DRM) with Hybrid Bòundary Node Method(HBNM),the Dual Reciprocity Hybrid Boundary Node Method (DRHBNM) is developed for three-dimensional linear elasticity problems with body force.This method can be used to solve the elasticity problems with body force without domain integral,which is inevitable by HBNM.To demonstrate the versatility and the fast convergence of this method,some numerical examples of 3-D elasticity problems with body forces are examined.The computational results show that the present method is effective and can be widely applied in solving practical engineering problems.

  11. Effect of three-body forces on the lattice dynamics of noble metals

    Indian Academy of Sciences (India)

    P R Vyas; C V Pandya; T C Pandya; V B Gohel

    2001-04-01

    A simple method to generate an effective electron–ion interaction pseudopotential from the energy wave number characteristic obtained by first principles calculations has been suggested. This effective potential has been used, in third order perturbation, to study the effect of three-body forces on the lattice dynamics of noble metals. It is found that three-body forces, in these metals, do play an important role. The inclusion of such three-body forces appreciably improves the agreement between the experimental and theoretical phonon dispersion curves.

  12. The body force in a three-dimensional Lame' system: identification and regularization

    CERN Document Server

    Trong, Dang Duc; Thuc, Phung Trong

    2011-01-01

    Let a three-dimensional isotropic elastic body be described by the Lam\\'e system with the body force of the form $F(x,t)=\\phi(t)f(x)$, where $\\phi$ is known. We consider the problem of determining the unknown spatial term $f(x)$ of the body force where the surface stress history is given as the overdetermination. This inverse problem is ill-posed. Using the interpolation method and truncated Fourier series, we construct a regularized solution from approximate data and provide explicit error estimates. AMS 2010 Subject Classification: 35L20, 35R30. Keywords: Body force, elastic, ill$-$posed problem, interpolation, Fourier series.

  13. Volumetric Virtual Environments

    Institute of Scientific and Technical Information of China (English)

    HE Taosong

    2000-01-01

    Driven by fast development of both virtual reality and volume visualization, we discuss some critical techniques towards building a volumetric VR system, specifically the modeling, rendering, and manipulations of a volumetric scene.Techniques such as voxel-based object simplification, accelerated volume rendering,fast stereo volume rendering, and volumetric "collision detection" are introduced and improved, with the idea of demonstrating the possibilities and potential benefits of incorporating volumetric models into VR systems.

  14. Microscopic Three-Body Force Effect on Nucleon-Nucleon Cross Sections in Symmetric Nuclear Matter

    Institute of Scientific and Technical Information of China (English)

    ZHANG Hong-Fei; ZUO Wei; Lombardo Umberto; LI Zeng-Hua; LI Jun-Qing

    2008-01-01

    We provide a microscopic calculation of neutron-proton and proton-proton cross sections in symmetric nuclear matter at various densities, using the Brueckner-Hartree-Fock approximation scheme with the Argonne V14 potential including the contribution of microscopic three-body force. We investigate separately the effects of three-body force on the effective mass and on the scattering amplitude. In the present calculation, the rearrangement contribution of three-body force is considered, which will reduce the neutron and proton effective mass, and depress the amplitude of cross section. The effect of three body force is shown to be repulsive, especially in high densities and large momenta, which will suppress the cross section markedly.

  15. Model Study of Three-Body Forces in the Three-Body Bound State

    CERN Document Server

    Liu, H; Glöckle, W; Elster, Ch.

    2003-01-01

    The Faddeev equations for the three-body bound state with two- and three-body forces are solved directly as three-dimensional integral equation. The numerical feasibility and stability of the algorithm, which does not employ partial wave decomposition is demonstrated. The three-body binding energy and the full wave function are calculated with Malfliet-Tjon-type two-body potentials and scalar Fujita-Miyazawa type three-body forces. The influence of the strength and range of the three-body force on the wave function, single particle momentum distributions and the two-body correlation functions are studied in detail. The extreme case of pure three-body forces is investigated as well.

  16. Nuclear symmetry energy and the role of three-body forces

    CERN Document Server

    Goudarzi, S; Haensel, P

    2016-01-01

    Density dependence of nuclear symmetry energy as well as its partial wave decomposition is studied within the framework of lowest-order constrained variational (LOCV) method using AV18 two-body interaction supplemented by UIX three-body force. The main focus of the present work is to introduce a revised version of three-body force which is based on an isospin-dependent parametrization of coefficients in the UIX force, in order to overcome the inability to produce correct saturation-point parameters} in the framework of LOCV method. We find that employing the new model of {\\ph three-body force} in the LOCV formalism leads to successfully reproducing the semi-empirical parameters of cold nuclear matter, including} $E_{sym}(\\rho_0)$, $L$, and $K_{sym}$. All our models of three-body force combined with AV18 two-body force give maximum neutron star mass higher than $2\\;M_\\odot$. The fraction of protons in the nucleon cores of neutron stars strongly depends on the three-body force parametrization.

  17. Many-body forces and stability of the alkaline-earth tetramers

    Energy Technology Data Exchange (ETDEWEB)

    Diaz-Torrejon, C.C. [Centro Nacional de Supercomputo, IPICyT, A.C., Camino a la Presa San Jose 2055, 78216 San Luis Potosi, SLP (Mexico); Centro de Investigacion en Materiales Avanzados, S.C., Av. Miguel de Cervantes 120, 31109 Chihuahua, Chih. (Mexico); Kaplan, Ilya G., E-mail: kaplan@iim.unam.mx [Instituto de Investigaciones en Materiales, UNAM, Apdo. Postal 70-360, 04510 Mexico D.F. (Mexico)

    2011-03-18

    Graphical abstract: Many-body forces effect. In a three-particle system, the two-body interaction energies depend upon coordinates of all three particles. The comparative study of the interaction energy and its many-body decomposition for alkaline-earths tetramers Be{sub 4}, Mg{sub 4}, and Ca{sub 4} at the all-electron CCSD(T)/aug-cc-pVQZ level is performed. For study of dependence of the binding energy and the orbital population on the cluster size the corresponding dimers and trimers were also calculated at the same level of theory. In comparison with weakly bound dimers, the binding energy in trimers and, especially, in tetramers drastically increases; e.g., E{sub b}/N in Be{sub 3} is 7 times larger and in Be{sub 4} is 18.4 times larger than in Be{sub 2}. This sharp increase is explained as a manifestation of many-body forces. The trimers and tetramers are stabilized by the three-body forces, whereas the two- and four-body forces are repulsive. The attractive contribution to the three-body forces has a three-atom electron exchange origin. The natural bond orbital (NBO) population analysis reveals a relatively large np-population in trimers and tetramers. The population of the valence np-orbitals leads to the sp-hybridization providing the covalent bonding. Research highlights: {yields} The alkaline-earths trimers and tetramers are stabilized by the three-body forces. {yields} Two- and four-body forces are repulsive for trimers and tetramers. {yields} The attractive contribution to the three-body forces has a three-atom electron exchange origin. {yields} The population of the np-orbitals leads to the sp-hybridization providing the covalent bonding. - Abstract: The comparative study of the interaction energy and its many-body decomposition for Be{sub 4}, Mg{sub 4}, and Ca{sub 4} at the all-electron CCSD(T)/aug-cc-pVQZ level is performed. For study of dependence of the binding energy and the orbital population on the cluster size the corresponding dimers and

  18. A Benchmark Calculation for the Nd Scattering with a Model Three-Body Force

    CERN Document Server

    Phyu, Aye Mya; Golak, Jacek; Oo, Htun Htun; Witala, Henryk; Gloeckle, Walter

    2012-01-01

    Using the complex energy method, the problem of nucleon-deuteron scattering is solved with a simple three-body force having a separable form. Our results are compared with the results of modern direct two-variable calculations and a good agreement is found. This forms a firm base for other applications of the complex energy method.

  19. Experimental Study on the Body Force Field of Dielectric Barrier Discharge Actuators

    NARCIS (Netherlands)

    Kotsonis, M.; Ghaemi, S.; Giepman, R.H.M.; Veldhuis, L.L.M.

    2010-01-01

    An experimental investigation on thrust and body force of Dielectric Barrier Discharge (DBD) /plasma actuators aimed at low power flow control applications is presented. A parametric study on thrust is conducted for a wide range of geometrical configurations as well as several electrical operational

  20. Film Condensation with and Without Body Force in Boundary-Layer Flow of Vapor Over a Flat Plate

    Science.gov (United States)

    Chung, Paul M.

    1961-01-01

    Laminar film condensation under the simultaneous influence of gas-liquid interface shear and body force (g force) is analyzed over a flat plate. Important parameters governing condensation and heat transfer of pure vapor are determined. Mixtures of condensable vapor and noncondensable gas are also analyzed. The conditions under which the body force has a significant influence on condensation are determined.

  1. On symmetric equilibrium of an isothermal gas with a free boundary and a body force

    Directory of Open Access Journals (Sweden)

    2006-01-01

    Full Text Available The equation of symmetric equilibrium of an isothermal gas with an unknown boundary in the field of a body force is considered. Conditions for solvability and insolvability of the problem as well as for uniqueness and nonuniqueness of solutions are presented. Examples of finite, countable, or continual sets of solutions are constructed including equipotential ones. Static stability of solutions is analyzed too.

  2. Streamwise-body-force-model for rapid simulation combining internal and external flow fields

    Directory of Open Access Journals (Sweden)

    Cui Rong

    2016-10-01

    Full Text Available A streamwise-body-force-model (SBFM is developed and applied in the overall flow simulation for the distributed propulsion system, combining internal and external flow fields. In view of axial stage effects, fan or compressor effects could be simplified as body forces along the streamline. These body forces which are functions of local parameters could be added as source terms in Navier-Stokes equations to replace solid boundary conditions of blades and hubs. The validation of SBFM with uniform inlet and distortion inlet of compressors shows that pressure performance characteristics agree well with experimental data. A three-dimensional simulation of the integration configuration, via a blended wing body aircraft with a distributed propulsion system using the SBFM, has been completed. Lift coefficient and drag coefficient agree well with wind tunnel test results. Results show that to reach the goal of rapid integrated simulation combining internal and external flow fields, the computational fluid dynamics method based on SBFM is reasonable.

  3. Analytical equation of state with three-body forces: application to noble gases.

    Science.gov (United States)

    del Río, Fernando; Díaz-Herrera, Enrique; Guzmán, Orlando; Moreno-Razo, José Antonio; Ramos, J Eloy

    2013-11-14

    We developed an explicit equation of state (EOS) for small non polar molecules by means of an effective two-body potential. The average effect of three-body forces was incorporated as a perturbation, which results in rescaled values for the parameters of the two-body potential. These values replace the original ones in the EOS corresponding to the two-body interaction. We applied this procedure to the heavier noble gases and used a modified Kihara function with an effective Axilrod-Teller-Muto (ATM) term to represent the two- and three-body forces. We also performed molecular dynamics simulations with two- and three-body forces. There was good agreement between predicted, simulated, and experimental thermodynamic properties of neon, argon, krypton, and xenon, up to twice the critical density and up to five times the critical temperature. In order to achieve 1% accuracy of the pressure at liquid densities, the EOS must incorporate the effect of ATM forces. The ATM factor in the rescaled two-body energy is most important at temperatures around and lower than the critical one. Nonetheless, the rescaling of two-body diameter cannot be neglected at liquid-like densities even at high temperature. This methodology can be extended straightforwardly to deal with other two- and three-body potentials. It could also be used for other nonpolar substances where a spherical two-body potential is still a reasonable coarse-grain approximation.

  4. An actuator line model simulation with optimal body force projection length scales

    Science.gov (United States)

    Martinez-Tossas, Luis; Churchfield, Matthew J.; Meneveau, Charles

    2016-11-01

    In recent work (Martínez-Tossas et al. "Optimal smoothing length scale for actuator line models of wind turbine blades", preprint), an optimal body force projection length-scale for an actuator line model has been obtained. This optimization is based on 2-D aerodynamics and is done by comparing an analytical solution of inviscid linearized flow over a Gaussian body force to the potential flow solution of flow over a Joukowski airfoil. The optimization provides a non-dimensional optimal scale ɛ / c for different Joukowski airfoils, where ɛ is the width of the Gaussian kernel and c is the chord. A Gaussian kernel with different widths in the chord and thickness directions can further reduce the error. The 2-D theory developed is extended by simulating a full scale rotor using the optimal body force projection length scales. Using these values, the tip losses are captured by the LES and thus, no additional explicit tip-loss correction is needed for the actuator line model. The simulation with the optimal values provides excellent agreement with Blade Element Momentum Theory. This research is supported by the National Science Foundation (Grant OISE-1243482, the WINDINSPIRE project).

  5. Displacement Ventilation

    DEFF Research Database (Denmark)

    Nielsen, Peter Vilhelm

    Displacement ventilation is an interesting new type of air distribution principle which should be considered in connection with design of comfort ventilation in both smal1 and large spaces. Research activities on displacement ventilation are large all over the world and new knowledge of design...... methods appears continuously. This book gives an easy introduction to the basis of displacement ventilation and the chapters are written in the order which is used in a design procedure. The main text is extended by five appendices which show some of the new research activities taking place at Aalborg...

  6. Task III: Development of an Effective Computational Methodology for Body Force Representation of High-speed Rotor 37

    Science.gov (United States)

    Tan, Choon-Sooi; Suder, Kenneth (Technical Monitor)

    2003-01-01

    A framework for an effective computational methodology for characterizing the stability and the impact of distortion in high-speed multi-stage compressor is being developed. The methodology consists of using a few isolated-blade row Navier-Stokes solutions for each blade row to construct a body force database. The purpose of the body force database is to replace each blade row in a multi-stage compressor by a body force distribution to produce same pressure rise and flow turning. To do this, each body force database is generated in such a way that it can respond to the changes in local flow conditions. Once the database is generated, no hrther Navier-Stokes computations are necessary. The process is repeated for every blade row in the multi-stage compressor. The body forces are then embedded as source terms in an Euler solver. The method is developed to have the capability to compute the performance in a flow that has radial as well as circumferential non-uniformity with a length scale larger than a blade pitch; thus it can potentially be used to characterize the stability of a compressor under design. It is these two latter features as well as the accompanying procedure to obtain the body force representation that distinguish the present methodology from the streamline curvature method. The overall computational procedures have been developed. A dimensional analysis was carried out to determine the local flow conditions for parameterizing the magnitudes of the local body force representation of blade rows. An Euler solver was modified to embed the body forces as source terms. The results from the dimensional analysis show that the body forces can be parameterized in terms of the two relative flow angles, the relative Mach number, and the Reynolds number. For flow in a high-speed transonic blade row, they can be parameterized in terms of the local relative Mach number alone.

  7. Cluster variational method for nuclear matter with the three-body force

    Energy Technology Data Exchange (ETDEWEB)

    Takano, M.; Togashi, H.; Yamamuro, S.; Nakazato, K.; Suzuki, H. [Research Institute for Science and Engineering, Waseda University, 3-4-1 Okubo, Shinjuku-ku, Tokyo 169-8555 Japan and Department of Physics and Applied Physics, Waseda University, 3-4-1 Okubo, Shinjuku-ku, Tokyo 169-8555 (Japan); Department of Physics and Applied Physics, Waseda University, 3-4-1 Okubo, Shinjuku-ku, Tokyo 169-8555 (Japan); Department of Physics, Faculty of Science and Technology, Tokyo University of Science, Yamazaki 2641, Noda, Chiba 278-8510 (Japan)

    2012-11-12

    We report the current status of our project to construct a new nuclear equation of state (EOS), which may be used for supernova numerical simulations, based on the cluster variational method starting from the realistic nuclear Hamiltonian. We also take into account a higher-order correction to the energy of the nuclear three-body force (TBF). The nuclear EOSs with and without the higher-order TBF correction at zero temperature are very close to each other, when parameters are readjusted so as to reproduce the empirical saturation data.

  8. Research on the Earth system multi-body force system dynamical model

    Institute of Scientific and Technical Information of China (English)

    CHEN; Xiaofei; BI; Siwen; WU; Fei; DONG; Qianlin

    2006-01-01

    This paper presents an overview of the binding force and freedom force of Earth system, and describes force moment to point and line and force system in the Earth system. It introduces the force theory of the Earth system multi-body force system from special or equivalent force system of Earth system mechanics, general force and no-power force of Earth system. Finally it describes the force and moment of nodes of Earth system and provides basic model for the research of the Earth system multi-body dynamics.

  9. Displacement Ventilation

    DEFF Research Database (Denmark)

    Bjørn, Erik; Mattsson, Magnus; Sandberg, Mats

    Full-scale experiments were made in a displacement ventilated room with two breathing thermal manikins to study the effect of movements and breathing on the vertical contaminant distribution, and on the personal exposure of occupants. Concentrations were measured with tracer gas equipment...

  10. Three-Body Force Effects on EOS of Asymmetric Nuclear Matter and Proton Fraction in Neutron Star Matter

    Institute of Scientific and Technical Information of China (English)

    ZUO Wei; A.Lejeune; U.Lombardo; J.F.Mathiot

    2003-01-01

    The three-body force effects on the equation of state and its iso-spin dependence of asymmetric nuclearmatter and on the proton fraction in neutron star matter have been investigated within Brueckner-Hartree-Fock approachby using a microscopic three-body force. It is shown that, even in the presence of the three-body force, the empiricalparabolic law of the energy per nucleon vs. isospin asymmetry β= ( N - Z) /A is fulfilled in the whole asymmetry range0≤β≤1 and also up to high density. The three-body force provides a strong enhancement of symmetry energy at highdensity in agreement with relativistic approaches. It also shows that the three-body force leads to a much more rapidincreasing of symmetry energy with density in relatively high density region and to a much lower threshold density forthe direct URCA process to occur in a neutron star as compared to the predictions adopting only pure two-body force.

  11. Volumetric composition of nanocomposites

    DEFF Research Database (Denmark)

    Madsen, Bo; Lilholt, Hans; Mannila, Juha

    2015-01-01

    Detailed characterisation of the properties of composite materials with nanoscale fibres is central for the further progress in optimization of their manufacturing and properties. In the present study, a methodology for the determination and analysis of the volumetric composition of nanocomposites...... is presented, using cellulose/epoxy and aluminosilicate/polylactate nanocomposites as case materials. The buoyancy method is used for the accurate measurements of materials density. The accuracy of the method is determined to be high, allowing the measured nanocomposite densities to be reported with 5...... significant figures. The plotting of the measured nanocomposite density as a function of the nanofibre weight content is shown to be a first good approach of assessing the porosity content of the materials. The known gravimetric composition of the nanocomposites is converted into a volumetric composition...

  12. WearDY: Wearable dynamics. A prototype for human whole-body force and motion estimation

    Science.gov (United States)

    Latella, Claudia; Kuppuswamy, Naveen; Nori, Francesco

    2016-06-01

    Motion capture is a powerful tool used in a large range of applications towards human movement analysis. Although it is a well-established technique, its main limitation is the lack of dynamic information such as forces and torques during the motion capture. In this paper, we present a novel approach for human wearable dynamic (WearDY) motion capture for the simultaneous estimation of whole-body forces along with the motion. Our conceptual framework encompasses traditional passive markers based methods, inertial and contact force sensor modalities and harnesses a probabilistic computational framework for estimating dynamic quantities originally proposed in the domain of humanoid robot control. We present preliminary experimental analysis of our framework on subjects performing a two Degrees-of-Freedom bowing task and we estimate the motion and dynamic quantities. We discuss the implication of our proposal towards the design of a novel wearable force and motion capture suit and its applications.

  13. Local stress and heat flux in atomistic systems involving three-body forces.

    Science.gov (United States)

    Chen, Youping

    2006-02-01

    Local densities of fundamental physical quantities, including stress and heat flux fields, are formulated for atomistic systems involving three-body forces. The obtained formulas are calculable within an atomistic simulation, in consistent with the conservation equations of thermodynamics of continuum, and can be applied to systems with general two- and three-body interaction forces. It is hoped that this work may correct some misuse of inappropriate formulas of stress and heat flux in the literature, may clarify the definition of site energy of many-body potentials, and may serve as an analytical link between an atomistic model and a continuum theory. Physical meanings of the obtained formulas, their relation with virial theorem and heat theorem, and the applicability are discussed.

  14. Flexible Volumetric Structure

    Science.gov (United States)

    Cagle, Christopher M. (Inventor); Schlecht, Robin W. (Inventor)

    2014-01-01

    A flexible volumetric structure has a first spring that defines a three-dimensional volume and includes a serpentine structure elongatable and compressible along a length thereof. A second spring is coupled to at least one outboard edge region of the first spring. The second spring is a sheet-like structure capable of elongation along an in-plane dimension thereof. The second spring is oriented such that its in-plane dimension is aligned with the length of the first spring's serpentine structure.

  15. Displacing use

    DEFF Research Database (Denmark)

    Kelly, Janet; Matthews, Ben

    2014-01-01

    -centred design process. We identified alternative design-relevant relationships between people and devices that are not specifically tied to the functions/uses of the devices, e.g. relationships between the healthcare professional and the device, between doctors and patients, and between patients and their own......This paper critically discusses the concept of use in design, suggesting that relevant relationships other than use are sometimes obscured by the usercentredness of design processes. We present a design case from the medical device domain that displaced the concept of use from the centre of a human...

  16. Equilibrium theory of fluids in the presence of three-body forces

    Science.gov (United States)

    Sinha, S. K.; Ram, J.; Singh, Y.

    1985-10-01

    Using the functional differentiation and topological reduction technique, we derive effective pair potentials to describe the correlation functions and thermodynamic properties of fluids in the presence of three-body forces. Relations between effective pair potentials derived from different properties are discussed. The pair correlation function is calculated using the Percus-Yevick integral equation theory and the hypernetted chain integral equation perturbation theory, the results are reported for neon, argon and xenon. Monte Carlo simulation is also done for Xe using the effective pair potential. The agreement found between the pair correlation function calculated from the integral equation perturbation theory and Monte Carlo simulation is good. The effect of the triple dipole and dipole-dipole-quadrupole interactions on the structure of fluid is found to be very small except near the first peak. We, however, except the sizable change in the structure factor S( q) for q < 1.0 Å -1. The effect of the three-body interactions on the thermodynamic properties like internal energy and pressure is always measurable.

  17. Extraction of user's navigation commands from upper body force interaction in walker assisted gait

    Directory of Open Access Journals (Sweden)

    Pons José L

    2010-08-01

    Full Text Available Abstract Background The advances in technology make possible the incorporation of sensors and actuators in rollators, building safer robots and extending the use of walkers to a more diverse population. This paper presents a new method for the extraction of navigation related components from upper-body force interaction data in walker assisted gait. A filtering architecture is designed to cancel: (i the high-frequency noise caused by vibrations on the walker's structure due to irregularities on the terrain or walker's wheels and (ii the cadence related force components caused by user's trunk oscillations during gait. As a result, a third component related to user's navigation commands is distinguished. Results For the cancelation of high-frequency noise, a Benedict-Bordner g-h filter was designed presenting very low values for Kinematic Tracking Error ((2.035 ± 0.358·10-2 kgf and delay ((1.897 ± 0.3697·101ms. A Fourier Linear Combiner filtering architecture was implemented for the adaptive attenuation of about 80% of the cadence related components' energy from force data. This was done without compromising the information contained in the frequencies close to such notch filters. Conclusions The presented methodology offers an effective cancelation of the undesired components from force data, allowing the system to extract in real-time voluntary user's navigation commands. Based on this real-time identification of voluntary user's commands, a classical approach to the control architecture of the robotic walker is being developed, in order to obtain stable and safe user assisted locomotion.

  18. Job Displacement and Crime

    DEFF Research Database (Denmark)

    Bennett, Patrick; Ouazad, Amine

    that displaced workers' propensity to commit crime is higher than non-displaced workers before the displacement event; but it is significantly higher afterwards. Displacement impacts crime over and above what is explained by earnings losses and weeks of unemployment following displacement....

  19. Quantitative Techniques in Volumetric Analysis

    Science.gov (United States)

    Zimmerman, John; Jacobsen, Jerrold J.

    1996-12-01

    Quantitative Techniques in Volumetric Analysis is a visual library of techniques used in making volumetric measurements. This 40-minute VHS videotape is designed as a resource for introducing students to proper volumetric methods and procedures. The entire tape, or relevant segments of the tape, can also be used to review procedures used in subsequent experiments that rely on the traditional art of quantitative analysis laboratory practice. The techniques included are: Quantitative transfer of a solid with a weighing spoon Quantitative transfer of a solid with a finger held weighing bottle Quantitative transfer of a solid with a paper strap held bottle Quantitative transfer of a solid with a spatula Examples of common quantitative weighing errors Quantitative transfer of a solid from dish to beaker to volumetric flask Quantitative transfer of a solid from dish to volumetric flask Volumetric transfer pipet A complete acid-base titration Hand technique variations The conventional view of contemporary quantitative chemical measurement tends to focus on instrumental systems, computers, and robotics. In this view, the analyst is relegated to placing standards and samples on a tray. A robotic arm delivers a sample to the analysis center, while a computer controls the analysis conditions and records the results. In spite of this, it is rare to find an analysis process that does not rely on some aspect of more traditional quantitative analysis techniques, such as careful dilution to the mark of a volumetric flask. Figure 2. Transfer of a solid with a spatula. Clearly, errors in a classical step will affect the quality of the final analysis. Because of this, it is still important for students to master the key elements of the traditional art of quantitative chemical analysis laboratory practice. Some aspects of chemical analysis, like careful rinsing to insure quantitative transfer, are often an automated part of an instrumental process that must be understood by the

  20. Space-Time Transfinite Interpolation of Volumetric Material Properties.

    Science.gov (United States)

    Sanchez, Mathieu; Fryazinov, Oleg; Adzhiev, Valery; Comninos, Peter; Pasko, Alexander

    2015-02-01

    The paper presents a novel technique based on extension of a general mathematical method of transfinite interpolation to solve an actual problem in the context of a heterogeneous volume modelling area. It deals with time-dependent changes to the volumetric material properties (material density, colour, and others) as a transformation of the volumetric material distributions in space-time accompanying geometric shape transformations such as metamorphosis. The main idea is to represent the geometry of both objects by scalar fields with distance properties, to establish in a higher-dimensional space a time gap during which the geometric transformation takes place, and to use these scalar fields to apply the new space-time transfinite interpolation to volumetric material attributes within this time gap. The proposed solution is analytical in its nature, does not require heavy numerical computations and can be used in real-time applications. Applications of this technique also include texturing and displacement mapping of time-variant surfaces, and parametric design of volumetric microstructures.

  1. Test Facility for Volumetric Absorber

    Energy Technology Data Exchange (ETDEWEB)

    Ebert, M.; Dibowski, G.; Pfander, M.; Sack, J. P.; Schwarzbozl, P.; Ulmer, S.

    2006-07-01

    Long-time testing of volumetric absorber modules is an inevitable measure to gain the experience and reliability required for the commercialization of the open volumetric receiver technology. While solar tower test facilities are necessary for performance measurements of complete volumetric receivers, the long-term stability of individual components can be tested in less expensive test setups. For the qualification of the aging effects of operating cycles on single elements of new absorber materials and designs, a test facility was developed and constructed in the framework of the KOSMOSOL project. In order to provide the concentrated solar radiation level, the absorber test facility is integrated into a parabolic dish system at the Plataforma Solar de Almeria (PSA) in Spain. Several new designs of ceramic absorbers were developed and tested during the last months. (Author)

  2. Myocardial kinematics based on tagged MRI from volumetric NURBS models

    Science.gov (United States)

    Tustison, Nicholas J.; Amini, Amir A.

    2004-04-01

    We present current research in which left ventricular deformation is estimated from tagged cardiac magnetic resonance imaging using volumetric deformable models constructed from nonuniform rational B-splines (NURBS). From a set of short and long axis images at end-diastole, the initial NURBS model is constructed by fitting two surfaces with the same parameterization to the set of epicardial and endocardial contours from which a volumetric model is created. Using normal displacements of the three sets of orthogonal tag planes as well as displacements of both tag line and contour/tag line intersection points, one can solve for the optimal homogeneous coordinates, in a least squares sense, of the control points of the NURBS model at a later time point using quadratic programming. After fitting to all time points of data, lofting the NURBS model at each time point creates a comprehensive 4-D NURBS model. From this model, we can extract 3-D myocardial displacement fields and corresponding strain maps, which are local measures of non-rigid deformation.

  3. A consistent method for finite volume discretization of body forces on collocated grids applied to flow through an actuator disk

    DEFF Research Database (Denmark)

    Troldborg, Niels; Sørensen, Niels N.; Réthoré, Pierre-Elouan;

    2015-01-01

    This paper describes a consistent algorithm for eliminating the numerical wiggles appearing when solving the finite volume discretized Navier-Stokes equations with discrete body forces in a collocated grid arrangement. The proposed method is a modification of the Rhie-Chow algorithm where the force...... in a cell is spread on neighboring cells by applying equivalent pressure jumps at the cell faces. The method shows excellent results when applied for simulating the flow through an actuator disk, which is relevant for wind turbine wake simulations. (c) 2015 Elsevier Ltd. All rights reserved....

  4. Job Displacement and Crime

    DEFF Research Database (Denmark)

    Bennett, Patrick; Ouazad, Amine

    individuals, i.e. high-tenure workers with strong attachment to their firm, who lose employment during a mass-layoff event. Pre-displacement data suggests no evidence of endogenous selection of workers for displacement during mass-layoffs: displaced workers’ propensity to commit crime exhibits...... theory of crime. Marital dissolution is more likely post-displacement, and we find small intra-family externalities of adult displacement on younger family members’ crime. The impact of displacement on crime is stronger in municipalities with higher capital and labor income inequalities....

  5. Flow in complex domains simulated by Dissipative Particle Dynamics driven by geometry-specific body-forces

    Science.gov (United States)

    Yazdani, Alireza; Deng, Mingge; Caswell, Bruce; Karniadakis, George Em

    2016-01-01

    We demonstrate how the quality of simulations by Dissipative Particle Dynamics (DPD) of flows in complex geometries is greatly enhanced when driven by body forces suitably tailored to the geometry. In practice, the body force fields are most conveniently chosen to be the pressure gradient of the corresponding Navier-Stokes (N-S) flow. In the first of three examples, the driving-force required to yield a stagnation-point flow is derived from the pressure field of the potential flow for a lattice of counter-rotating line vortices. Such a lattice contains periodic squares bounded by streamlines with four vortices within them. Hence, the DPD simulation can be performed with periodic boundary conditions to demonstrate the value of a non-uniform driving-force without the need to model real boundaries. The second example is an irregular geometry consisting of a 2D rectangular cavity on one side of an otherwise uniform channel. The Navier-Stokes pressure field for the same geometry is obtained numerically, and its interpolated gradient is then employed as the driving-force for the DPD simulation. Finally, we present a third example, where the proposed method is applied to a complex 3D geometry of an asymmetric constriction. It is shown that in each case the DPD simulations closely reproduce the Navier-Stokes solutions. Convergence rates are found to be much superior to alternative methods; in addition, the range of convergence with respect to Reynolds number and Mach number is greatly extended.

  6. Significance of Neglected Hydrodynamic Forces on the Motion of Submerged Particles Acted on by External Body Forces

    Science.gov (United States)

    Cooper, Daniel; Charonko, John; Vlachos, Pavlos

    2011-11-01

    Recently, the manipulation of submerged particles using electromagnetic body forces has drawn increasing interest from a variety of fields, particularly medicine, where electrophoretic manipulation in lab-on-a-chip applications and magnetic drug targeting have become important areas of interest. As a direct result of this increasing interest a large number of simulations have been performed investigating the performance of devices and systems whose operation is based upon these physics. In the vast majority of cases, these simulations are based upon a force balance of the applicable body force and Stokes drag. Such simulations neglect additional hydrodynamic forces, including the added mass, Basset, Saffman, and Magnus forces. In the current study, the full equations of motion containing all of the aforementioned terms are nondimensionalized leading to a set of nondimensional parameters governing the behavior of the particle. A parametric investigation is then performed by calculating particle trajectories for both Poiseuille and Womersley flows. This analysis reveals that in many cases, the forces neglected in previous simulations are significant and should not be neglected in future studies.

  7. Statelessness and environmental displacement

    Directory of Open Access Journals (Sweden)

    Jessie Connell

    2015-05-01

    Full Text Available Stateless people and migrants are at greater risk of displacement and are less likely to receive assistance; in turn, environmental displacement (especially multiple migrations heightens the risk of becoming stateless.

  8. Using surface heave to estimate reservoir volumetric strain

    Energy Technology Data Exchange (ETDEWEB)

    Nanayakkara, A.S.; Wong, R.C.K. [Calgary Univ., AB (Canada)

    2008-07-01

    This paper presented a newly developed numerical tool for estimating reservoir volumetric strain distribution using surface vertical displacements and solving an inverse problem. Waterflooding, steam injection, carbon dioxide sequestration and aquifer storage recovery are among the subsurface injection operations that are responsible for reservoir dilations which propagate to the surrounding formations and extend to the surface resulting in surface heaves. Global positioning systems and surface tiltmeters are often used to measure the characteristics of these surface heaves and to derive valuable information regarding reservoir deformation and flow characteristics. In this study, Tikhonov regularization techniques were adopted to solve the ill-posed inversion problem commonly found in standard inversion techniques such as Gaussian elimination and least squares methods. Reservoir permeability was then estimated by inverting the volumetric strain distribution. Results of the newly developed numerical tool were compared with results from fully-coupled finite element simulation of fluid injection problems. The reservoir volumetric strain distribution was successfully estimated along with an approximate value for reservoir permeability.

  9. Volumetric Three-Dimensional Display Systems

    Science.gov (United States)

    Blundell, Barry G.; Schwarz, Adam J.

    2000-03-01

    A comprehensive study of approaches to three-dimensional visualization by volumetric display systems This groundbreaking volume provides an unbiased and in-depth discussion on a broad range of volumetric three-dimensional display systems. It examines the history, development, design, and future of these displays, and considers their potential for application to key areas in which visualization plays a major role. Drawing substantially on material that was previously unpublished or available only in patent form, the authors establish the first comprehensive technical and mathematical formalization of the field, and examine a number of different volumetric architectures. System level design strategies are presented, from which proposals for the next generation of high-definition predictable volumetric systems are developed. To ensure that researchers will benefit from work already completed, they provide: * Descriptions of several recent volumetric display systems prepared from material supplied by the teams that created them * An abstract volumetric display system design paradigm * An historical summary of 90 years of development in volumetric display system technology * An assessment of the strengths and weaknesses of many of the systems proposed to date * A unified presentation of the underlying principles of volumetric display systems * A comprehensive bibliography Beautifully supplemented with 17 color plates that illustrate volumetric images and prototype displays, Volumetric Three-Dimensional Display Systems is an indispensable resource for professionals in imaging systems development, scientific visualization, medical imaging, computer graphics, aerospace, military planning, and CAD/CAE.

  10. Job Displacement and Crime

    DEFF Research Database (Denmark)

    Bennett, Patrick; Ouazad, Amine

    This paper matches a comprehensive Danish employer-employee data set with individual crime information (timing of offenses, charges, convictions, and prison terms by crime type) to estimate the impact of job displacement on an individual’s propensity to commit crime. We focus on displaced individ...

  11. XY displacement device

    NARCIS (Netherlands)

    Heerens, W.C.; Laham, C.D.; Holman, A.E.

    1997-01-01

    An XY-displacement device (1) with a four-fold symmetry comprises a reference frame (10); an object mount (20) for holding an object (22) to be displaced; an X-manipulator (100) coupled between the reference frame (10) and the object mount (20), which provides a rigid coupling between the object mou

  12. Displacement data assimilation

    Science.gov (United States)

    Rosenthal, W. Steven; Venkataramani, Shankar; Mariano, Arthur J.; Restrepo, Juan M.

    2017-02-01

    We show that modifying a Bayesian data assimilation scheme by incorporating kinematically-consistent displacement corrections produces a scheme that is demonstrably better at estimating partially observed state vectors in a setting where feature information is important. While the displacement transformation is generic, here we implement it within an ensemble Kalman Filter framework and demonstrate its effectiveness in tracking stochastically perturbed vortices.

  13. A reduced volumetric expansion factor plot

    Science.gov (United States)

    Hendricks, R. C.

    1979-01-01

    A reduced volumetric expansion factor plot has been constructed for simple fluids which is suitable for engineering computations in heat transfer. Volumetric expansion factors have been found useful in correlating heat transfer data over a wide range of operating conditions including liquids, gases and the near critical region.

  14. The break-up of Ekman theory in a flow subjected to background rotation and driven by a non-conservative body force

    NARCIS (Netherlands)

    Duran-Matute, M.; Di Nitto, G.; Trieling, R.R.; Kamp, L.P.J.; van Heijst, G.J.F.

    2012-01-01

    We present an experimental/numerical study of a dipolar flow structure in a shallow layer of electrolyte driven by electromagnetic forcing and subjected to background rotation. The aim of this study is to determine the influence of a non-conservative body force on the range of applicability of the

  15. The break-up of Ekman theory in a flow subjected to background rotation and driven by a non-conservative body force

    NARCIS (Netherlands)

    Duran-Matute, M.; Di Nitto, G.; Trieling, R.R.; Kamp, L.P.J.; van Heijst, G.J.F.

    2012-01-01

    We present an experimental/numerical study of a dipolar flow structure in a shallow layer of electrolyte driven by electromagnetic forcing and subjected to background rotation. The aim of this study is to determine the influence of a non-conservative body force on the range of applicability of the c

  16. Advanced Triangulation Displacement Sensors

    Science.gov (United States)

    Poteet, Wade M.; Cauthen, Harold K.

    1996-01-01

    Advanced optoelectronic triangulation displacement sensors undergoing development. Highly miniaturized, more stable, more accurate, and relatively easy to use. Incorporate wideband electronic circuits suitable for real-time monitoring and control of displacements. Measurements expected to be accurate to within nanometers. In principle, sensors mass-produced at relatively low unit cost. Potential applications numerous. Possible industrial application in measuring runout of rotating shaft or other moving part during fabrication in "zero-defect" manufacturing system, in which measured runout automatically corrected.

  17. Displacement Data Assimilation

    CERN Document Server

    Rosenthal, W Steven; Mariano, Arthur J; Restrepo, Juan M

    2016-01-01

    We show that modifying a Bayesian data assimilation scheme by incorporating kinematically-consistent displacement corrections produces a scheme that is demonstrably better at estimating partially observed state vectors in a setting where feature information important. While the displacement transformation is not tied to any particular assimilation scheme, here we implement it within an ensemble Kalman Filter and demonstrate its effectiveness in tracking stochastically perturbed vortices.

  18. Iraqi Population Displacement Analysis

    Science.gov (United States)

    2016-11-01

    CENTER FOR ARMY ANALYSIS 6001 GOETHALS ROAD FORT BELVOIR, VA 22060-5230 CAA-2015098 IRAQI POPULATION DISPLACEMENT ANALYSIS NOVEMBER 2016...designated by other official documentation. Comments or suggestions should be addressed to: Director Center for Army Analysis ATTN: CSCA-OA...CONTRACT NUMBER Iraqi Population Displacement Analysis PDMC 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) 5d. PROJECT NUMBER Ms

  19. Advanced Triangulation Displacement Sensors

    Science.gov (United States)

    Poteet, Wade M.; Cauthen, Harold K.

    1996-01-01

    Advanced optoelectronic triangulation displacement sensors undergoing development. Highly miniaturized, more stable, more accurate, and relatively easy to use. Incorporate wideband electronic circuits suitable for real-time monitoring and control of displacements. Measurements expected to be accurate to within nanometers. In principle, sensors mass-produced at relatively low unit cost. Potential applications numerous. Possible industrial application in measuring runout of rotating shaft or other moving part during fabrication in "zero-defect" manufacturing system, in which measured runout automatically corrected.

  20. Internal displacement in Burma.

    Science.gov (United States)

    Lanjouw, S; Mortimer, G; Bamforth, V

    2000-09-01

    The internal displacement of populations in Burma is not a new phenomenon. Displacement is caused by numerous factors. Not all of it is due to outright violence, but much is a consequence of misguided social and economic development initiatives. Efforts to consolidate the state by assimilating populations in government-controlled areas by military authorities on the one hand, while brokering cease-fires with non-state actors on the other, has uprooted civilian populations throughout the country. Very few areas in which internally displaced persons (IDPs) are found are not facing social turmoil within a climate of impunity. Humanitarian access to IDP populations remains extremely problematic. While relatively little information has been collected, assistance has been focused on targeting accessible groups. International concern within Burma has couched the problems of displacement within general development modalities, while international attention along its borders has sought to contain displacement. With the exception of several recent initiatives, few approaches have gone beyond assistance and engaged in the prevention or protection of the displaced.

  1. Surfactant enhanced volumetric sweep efficiency

    Energy Technology Data Exchange (ETDEWEB)

    Harwell, J.H.; Scamehorn, J.F.

    1989-10-01

    Surfactant-enhanced waterflooding is a novel EOR method aimed to improve the volumetric sweep efficiencies in reservoirs. The technique depends upon the ability to induce phase changes in surfactant solutions by mixing with surfactants of opposite charge or with salts of appropriate type. One surfactant or salt solution is injected into the reservoir. It is followed later by injection of another surfactant or salt solution. The sequence of injections is arranged so that the two solutions do not mix until they are into the permeable regions well away from the well bore. When they mix at this point, by design they form a precipitate or gel-like coacervate phase, plugging this permeable region, forcing flow through less permeable regions of the reservoir, improving sweep efficiency. The selectivity of the plugging process is demonstrated by achieving permeability reductions in the high permeable regions of Berea sandstone cores. Strategies were set to obtain a better control over the plug placement and the stability of plugs. A numerical simulator has been developed to investigate the potential increases in oil production of model systems. Furthermore, the hardness tolerance of anionic surfactant solutions is shown to be enhanced by addition of monovalent electrolyte or nonionic surfactants. 34 refs., 32 figs., 8 tabs.

  2. Laser Based 3D Volumetric Display System

    Science.gov (United States)

    1993-03-01

    Literature, Costa Mesa, CA July 1983. 3. "A Real Time Autostereoscopic Multiplanar 3D Display System", Rodney Don Williams, Felix Garcia, Jr., Texas...8217 .- NUMBERS LASER BASED 3D VOLUMETRIC DISPLAY SYSTEM PR: CD13 0. AUTHOR(S) PE: N/AWIU: DN303151 P. Soltan, J. Trias, W. Robinson, W. Dahlke 7...laser generated 3D volumetric images on a rotating double helix, (where the 3D displays are computer controlled for group viewing with the naked eye

  3. Displacements and stresses in composite multi-layered media due to varying temperature and concentrated load

    Institute of Scientific and Technical Information of China (English)

    M. K. Ghosh; M. Kanoria

    2007-01-01

    This paper deals with the determination of the thermo-elastic displacements and stresses in a multi-layered body set up in different layers of different thickness having different elastic properties due to the application of heat and a concentrated load in the uppermost surface of the medium. Each layer is assumed to be made of homogeneous and isotropic elastic material. The relevant displacement components for each layer are taken to be axisymmetric about a line, which is perpendicular to the plane surfaces of all layers. The stress function for each layer, therefore, satisfies a single equation in absence of any body forces. The equation is then solved by integral transform technique. Analytical expressions for thermo-elastic displacements and stresses in the underlying mass and the corresponding numerical codes are constructed for any number of layers. However, the numerical comparison is made for three and four layers.

  4. Supersymmetric Displaced Number States

    Directory of Open Access Journals (Sweden)

    Fredy R. Zypman

    2015-06-01

    Full Text Available We introduce, generate and study a family of supersymmetric displaced number states (SDNS that can be considered generalized coherent states of the supersymmetric harmonic oscillator. The family is created from the seminal supersymmetric boson-fermion entangling annihilation operator introduced by Aragone and Zypman and later expanded by Kornbluth and Zypman. Using the momentum representation, the states are obtained analytically in compact form as displaced supersymmetric number states. We study their position-momentum uncertainties, and their bunchiness by classifying them according to their Mandel Q-parameter in phase space. We were also able to find closed form analytical representations in the space and number basis.

  5. Volume Displacement Effects in Bubble-laden Flows

    Science.gov (United States)

    Cihonski, Andrew; Finn, Justin; Apte, Sourabh

    2012-11-01

    When a few bubbles are entrained in a traveling vortex ring, it has been shown that even at extremely low volume loadings, their presence can significantly affect the structure of the vortex core (Sridhar & Katz 1999). A typical Euler-Lagrange point-particle model with two-way coupling for this dilute system, wherein the bubbles are assumed subgrid and momentum point-sources are used to model their effect on the flow, is shown to be unable to accurately capture the experimental trends of bubble settling location and vortex distortion for a range of bubble parameters and vortex strengths. The bubbles experience a significant amount of drag, lift, added mass, pressure, and gravity forces. However, these forces are in balance of each other, as the bubbles reach a mean settling location away from the vortex core. Accounting for fluid volume displacement due to bubble motion, using a model termed as volumetric coupling, experimental trends on vortex distortion and bubble settling location are well captured. The fluid displacement effects are studied by introducing a notion of a volumetric coupling force, the net force on the fluid due to volumetric coupling, which is found to be dominant even at the low volume loadings investigated here.

  6. Correlations in light nuclei and their relation to fine tuning and uncertainty quantifications of many body forces in low-energy nuclear physics

    CERN Document Server

    Lupu, Sergiu; Gazit, Doron

    2015-01-01

    The large nucleon-nucleon scattering length, and the isospin approximate symmetry, are low energy properties of quantum chromodynamics (QCD). These entail correlations in the binding energies of light nuclei, e.g., the A=3 iso-multiplet, and Tjon's correlation between the binding energy of three and four body nuclei. Using a new representation of these, we establish that they translate into a correlation between different short-range contributions to three body forces in chiral effective field theory of low-energy nuclear physics. We demonstrate that these correlations should be taken into account in order to avoid fine-tuning in the calibration of three body forces. We relate this to the role of correlations in uncertainty quantification of non-renormalizable effective field theories of the nuclear regime. In addition, we show that correlations can be useful in assessing the importance of forces induced by renormalization group (RG) transformations. We give numerical evidence that such RG transformations can...

  7. Job Displacement and Crime

    DEFF Research Database (Denmark)

    Bennett, Patrick; Ouazad, Amine

    We use a detailed employer-employee data set matched with detailed crime information (timing of crime, fines, convictions, crime type) to estimate the impact of job loss on an individual's probability to commit crime. We focus on job losses due to displacement, i.e. job losses in firms losing...

  8. Displacement compressors - acceptance tests

    CERN Document Server

    International Organization for Standardization. Geneva

    1996-01-01

    ISO 1217:2009 specifies methods for acceptance tests regarding volume rate of flow and power requirements of displacement compressors. It also specifies methods for testing liquid-ring type compressors and the operating and testing conditions which apply when a full performance test is specified.

  9. Volumetric flow rate comparisons for water and product on pasteurization systems.

    Science.gov (United States)

    Schlesser, J E; Stroup, W H; McKinstry, J A

    1994-04-01

    A flow calibration tube system was assembled to determine the volumetric flow rates for water and various dairy products through a holding tube, using three different flow promotion methods. With the homogenizer, the volumetric flow rates of water and reconstituted skim milk were within 1.5% of each other. With the positive displacement pump, the flow rate for reconstituted skim milk increased compared with that for water as the pressure increased or temperature decreased. The largest increase in flow rate was at 310-kPa gauge and 20 degrees C. On a magnetic flow meter system, the volumetric flow rates of water and reconstituted skim milk were within .5% of the flow rate measured from the volume collected in a calibrated tank. The flow rate of whole milk was similar to that of skim milk on the three flow promoters evaluated. Ice milk mix increased the flow rate of the positive displacement pump, but not the homogenizer and magnetic flow meter system.

  10. The photoelectric displacement converter

    Science.gov (United States)

    Dragoner, Valeriu V.

    2005-02-01

    In the article are examined questions of constructing photoelectric displacement converter satisfying demands that are stated above. Converter has channels of approximate and precise readings. The approximate reading may be accomplished either by the method of reading from a code mask or by the method of the consecutive calculation of optical scale gaps number. Phase interpolator of mouar strips" gaps is determined as a precise measuring. It is shown mathematical model of converter that allow evaluating errors and operating speed of conversion.

  11. HIGH TEMPERATURE DISPLACEMENT SENSOR

    Institute of Scientific and Technical Information of China (English)

    Xu Longxiang; Zhang Jinyu; Schweitzer Gerhard

    2005-01-01

    A high temperature displacement sensor based on the principle of eddy-current is investigated. A new temperature compensation technique by using eddy-current effect is presented to satisfy the special requirement at high temperature up to 550℃. The experiment shows that the temperature compensation technique leads to good temperature stability for the sensors. The variation of the sensitivity as well as the temperature drift of the sensor with temperature compensation technique is only about 7.4% and 90~350 mV at 550℃ compared with that at room temperature, and that of the sensor without temperature compensation technique is about 31.2% and 2~3 V at 550℃ compared with that at room temperature. A new dynamic calibration method for the eddy-current displacement sensor is presented, which is very easy to be realized especially in high frequency and at high temperatures. The high temperature displacement sensors developed are successfully used at temperature up to 550℃ in a magnetic bearing system for more than 100 h.

  12. Nonequilibrium volumetric response of shocked polymers

    Energy Technology Data Exchange (ETDEWEB)

    Clements, B E [Los Alamos National Laboratory

    2009-01-01

    Polymers are well known for their non-equilibrium deviatoric behavior. However, investigations involving both high rate shock experiments and equilibrium measured thermodynamic quantities remind us that the volumetric behavior also exhibits a non-equilibrium response. Experiments supporting the notion of a non-equilibrium volumetric behavior will be summarized. Following that discussion, a continuum-level theory is proposed that will account for both the equilibrium and non-equilibrium response. Upon finding agreement with experiment, the theory is used to study the relaxation of a shocked polymer back towards its shocked equilibrium state.

  13. 黏性彻体力建模方法及其应用%Investigation on distributed viscous body force modeling and its application

    Institute of Scientific and Technical Information of China (English)

    刘超; 宁方飞

    2011-01-01

    The modeling method of viscous terms of Navier-Stokes equations using distributed viscous body forces was investigated. Then a fast calculation code for the three-dimensional (3-D) unsteady flow in turbomachine was developed, by solving 3-D unsteady Euler equations with the distributed viscous body force model. The code was used to simulate the unsteady flow in a two-stage compressor under circumferential total pressure inlet distortion, and the results were compared with Reynolds averaged Navier-Stokes (RANS)results. This demonstrates that, in the simulation of the unsteady flow in the multi-stage compressor under inlet distortion, the results obtained by the distributed viscous body force model agree well with the RANS results, with substantially less computational cost.%研究了将Navier-Stokes方程中黏性项简化为黏性彻体力的建模方法,并将该模型加入已有的计算流体力学(CFD)程序中,实现了用三维欧拉方程加黏性彻体力模型快速模拟叶轮机三维非定常流动的方法.使用该方法对进气周向总压畸变条件下的某双级压气机非定常流场进行了模拟,并与雷诺平均的Navier-Stokes(RANS)程序的计算结果进行了对比,结果表明,基于黏性彻体力模型的方法能以很少的计算资源给出与RANS模拟基本相当的计算结果.

  14. Second Order Darboux Displacements

    CERN Document Server

    Samsonov, B F; Negro, J; Nieto, L M

    2003-01-01

    The potentials for a one dimensional Schroedinger equation that are displaced along the x axis under second order Darboux transformations, called 2-SUSY invariant, are characterized in terms of a differential-difference equation. The solutions of the Schroedinger equation with such potentials are given analytically for any value of the energy. The method is illustrated by a two-soliton potential. It is proven that a particular case of the periodic Lame-Ince potential is 2-SUSY invariant. Both Bloch solutions of the corresponding Schroedinger equation equation are found for any value of the energy. A simple analytic expression for a family of two-gap potentials is derived.

  15. Displacing the patient

    DEFF Research Database (Denmark)

    Pors, Anja Svejgaard

    2012-01-01

    This analysis is based on an empirical study of a Danish hospital‟s communication programme entitled: 'The Perspective of the Patient'. The paper explores how strategic documents of the programme organize the communication work through situated displacements of the patient. Based on methodological...... elements from situational analysis (Clarke 2005) the analysis examines how the hospital‟s patient communication is not only about disease treatment, but rather about information treatment of the patient in order to attain a high level of patient satisfaction. The goal of patient satisfaction addresses both...

  16. Displacing the Patient

    DEFF Research Database (Denmark)

    Pors, Anja Svejgaard

    The analysis is based on an empirical study of a hospital’s communication strategy entitled: 'The Perspective of the Patient'. The paper asks how the strategy organizes communication work as situated displacements of the patient. Based on methodological elements from situational analysis (Clarke...... 2005) the analysis examines how the hospital’s patient communication is not just about disease treatment, but rather about information treatment of the patient in order to attain a high level of patient satisfaction. The goal of patient satisfaction addresses care-oriented understandings of the patient...

  17. Process conditions and volumetric composition in composites

    DEFF Research Database (Denmark)

    Madsen, Bo

    2013-01-01

    The obtainable volumetric composition in composites is linked to the gravimetric composition, and it is influenced by the conditions of the manufacturing process. A model for the volumetric composition is presented, where the volume fractions of fibers, matrix and porosity are calculated as a fun...... is increased. Altogether, the model is demonstrated to be a valuable tool for a quantitative analysis of the effect of process conditions. Based on the presented findings and considerations, examples of future work are mentioned for the further improvement of the model.......The obtainable volumetric composition in composites is linked to the gravimetric composition, and it is influenced by the conditions of the manufacturing process. A model for the volumetric composition is presented, where the volume fractions of fibers, matrix and porosity are calculated...... as a function of the fiber weight fraction, and where parameters are included for the composite microstructure, and the fiber assembly compaction behavior. Based on experimental data of composites manufactured with different process conditions, together with model predictions, different types of process related...

  18. Indexing Volumetric Shapes with Matching and Packing.

    Science.gov (United States)

    Koes, David Ryan; Camacho, Carlos J

    2015-04-01

    We describe a novel algorithm for bulk-loading an index with high-dimensional data and apply it to the problem of volumetric shape matching. Our matching and packing algorithm is a general approach for packing data according to a similarity metric. First an approximate k-nearest neighbor graph is constructed using vantage-point initialization, an improvement to previous work that decreases construction time while improving the quality of approximation. Then graph matching is iteratively performed to pack related items closely together. The end result is a dense index with good performance. We define a new query specification for shape matching that uses minimum and maximum shape constraints to explicitly specify the spatial requirements of the desired shape. This specification provides a natural language for performing volumetric shape matching and is readily supported by the geometry-based similarity search (GSS) tree, an indexing structure that maintains explicit representations of volumetric shape. We describe our implementation of a GSS tree for volumetric shape matching and provide a comprehensive evaluation of parameter sensitivity, performance, and scalability. Compared to previous bulk-loading algorithms, we find that matching and packing can construct a GSS-tree index in the same amount of time that is denser, flatter, and better performing, with an observed average performance improvement of 2X.

  19. Inverse modeling of InSAR and ground leveling data for 3D volumetric strain distribution

    Science.gov (United States)

    Gallardo, L. A.; Glowacka, E.; Sarychikhina, O.

    2015-12-01

    Wide availability of modern Interferometric Synthetic aperture Radar (InSAR) data have made possible the extensive observation of differential surface displacements and are becoming an efficient tool for the detailed monitoring of terrain subsidence associated to reservoir dynamics, volcanic deformation and active tectonism. Unfortunately, this increasing popularity has not been matched by the availability of automated codes to estimate underground deformation, since many of them still rely on trial-error subsurface model building strategies. We posit that an efficient algorithm for the volumetric modeling of differential surface displacements should match the availability of current leveling and InSAR data and have developed an algorithm for the joint inversion of ground leveling and dInSAR data in 3D. We assume the ground displacements are originated by a stress free-volume strain distribution in a homogeneous elastic media and determined the displacement field associated to an ensemble of rectangular prisms. This formulation is then used to develop a 3D conjugate gradient inversion code that searches for the three-dimensional distribution of the volumetric strains that predict InSAR and leveling surface displacements simultaneously. The algorithm is regularized applying discontinuos first and zero order Thikonov constraints. For efficiency, the resulting computational code takes advantage of the resulting convolution integral associated to the deformation field and some basic tools for multithreading parallelization. We extensively test our algorithm on leveling and InSAR test and field data of the Northwest of Mexico and compare to some feasible geological scenarios of underground deformation.

  20. Displaced patella fractures.

    Science.gov (United States)

    Della Rocca, Gregory J

    2013-10-01

    Displaced patella fractures often result in disruption of the extensor mechanism of the knee. An intact extensor mechanism is a requirement for unassisted gait. Therefore, operative treatment of the displaced patella fracture is generally recommended. The evaluation of the patella fracture patient includes examination of extensor mechanism integrity. Operative management of patella fractures normally includes open reduction with internal fixation, although partial patellectomy is occasionally performed, with advancement of quadriceps tendon or patellar ligament to the fracture bed. Open reduction with internal fixation has historically been performed utilizing anterior tension band wiring, although comminution of the fracture occasionally makes this fixation construct inadequate. Supplementation or replacement of the tension band wire construct with interfragmentary screws, cerclage wire or suture, and/or plate-and-screw constructs may add to the stability of the fixation construct. Arthrosis of the patellofemoral joint is very common after healing of patella fractures, and substantial functional deficits may persist long after fracture healing has occurred. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  1. Variable displacement blower

    Science.gov (United States)

    Bookout, Charles C.; Stotts, Robert E.; Waring, Douglass R.; Folsom, Lawrence R.

    1986-01-01

    A blower having a stationary casing for rotatably supporting a rotor assembly having a series of open ended chambers arranged to close against the surrounding walls of the casing. Pistons are slidably mounted within each chamber with the center of rotation of the pistons being offset in regard to the center of rotation of the rotor assembly whereby the pistons reciprocate in the chambers as the rotor assembly turns. As inlet port communicates with the rotor assembly to deliver a working substance into the chamber as the pistons approach a top dead center position in the chamber while an outlet port also communicates with the rotor to exhaust the working substance as the pistons approach a bottom dead center position. The displacement of the blower is varied by adjusting the amount of eccentricity between the center of rotation of the pistons and the center of rotation of the rotor assembly.

  2. Displacement Parameter Inversion for a Novel Electromagnetic Underground Displacement Sensor

    Directory of Open Access Journals (Sweden)

    Nanying Shentu

    2014-05-01

    Full Text Available Underground displacement monitoring is an effective method to explore deep into rock and soil masses for execution of subsurface displacement measurements. It is not only an important means of geological hazards prediction and forecasting, but also a forefront, hot and sophisticated subject in current geological disaster monitoring. In previous research, the authors had designed a novel electromagnetic underground horizontal displacement sensor (called the H-type sensor by combining basic electromagnetic induction principles with modern sensing techniques and established a mutual voltage measurement theoretical model called the Equation-based Equivalent Loop Approach (EELA. Based on that work, this paper presents an underground displacement inversion approach named “EELA forward modeling-approximate inversion method”. Combining the EELA forward simulation approach with the approximate optimization inversion theory, it can deduce the underground horizontal displacement through parameter inversion of the H-type sensor. Comprehensive and comparative studies have been conducted between the experimentally measured and theoretically inversed values of horizontal displacement under counterpart conditions. The results show when the measured horizontal displacements are in the 0–100 mm range, the horizontal displacement inversion discrepancy is generally tested to be less than 3 mm under varied tilt angles and initial axial distances conditions, which indicates that our proposed parameter inversion method can predict underground horizontal displacement measurements effectively and robustly for the H-type sensor and the technique is applicable for practical geo-engineering applications.

  3. Measuring vulnerability to disaster displacement

    Science.gov (United States)

    Brink, Susan A.; Khazai, Bijan; Power, Christopher; Wenzel, Friedemann

    2015-04-01

    Large scale disasters can cause devastating impacts in terms of population displacement. Between 2008 and 2013, on average 27 million people were displaced annually by disasters (Yonetani 2014). After large events such as hurricane Katrina or the Port-au-Prince earthquake, images of inadequate public shelter and concerns about large scale and often inequitable migration have been broadcast around the world. Population displacement can often be one of the most devastating and visible impacts of a natural disaster. Despite the importance of population displacement in disaster events, measures to understand the socio-economic vulnerability of a community often use broad metrics to estimate the total socio-economic risk of an event rather than focusing on the specific impacts that a community faces in a disaster. Population displacement is complex and multi-causal with the physical impact of a disaster interacting with vulnerability arising from the response, environmental issues (e.g., weather), cultural concerns (e.g., expectations of adequate shelter), and many individual factors (e.g., mobility, risk perception). In addition to the complexity of the causes, population displacement is difficult to measure because of the wide variety of different terms and definitions and its multi-dimensional nature. When we speak of severe population displacement, we may refer to a large number of displaced people, an extended length of displacement or associated difficulties such as poor shelter quality, risk of violence and crime in shelter communities, discrimination in aid, a lack of access to employment or other difficulties that can be associated with large scale population displacement. We have completed a thorough review of the literature on disaster population displacement. Research has been conducted on historic events to understand the types of negative impacts associated with population displacement and also the vulnerability of different groups to these impacts. We

  4. Combined surface and volumetric occlusion shading

    KAUST Repository

    Schott, Matthias O.

    2012-02-01

    In this paper, a method for interactive direct volume rendering is proposed that computes ambient occlusion effects for visualizations that combine both volumetric and geometric primitives, specifically tube shaped geometric objects representing streamlines, magnetic field lines or DTI fiber tracts. The proposed algorithm extends the recently proposed Directional Occlusion Shading model to allow the rendering of those geometric shapes in combination with a context providing 3D volume, considering mutual occlusion between structures represented by a volume or geometry. © 2012 IEEE.

  5. MR volumetric assessment of endolymphatic hydrops

    Energy Technology Data Exchange (ETDEWEB)

    Guerkov, R.; Berman, A.; Jerin, C.; Krause, E. [University of Munich, Department of Otorhinolaryngology Head and Neck Surgery, Grosshadern Medical Centre, Munich (Germany); University of Munich, German Centre for Vertigo and Balance Disorders, Grosshadern Medical Centre, Marchioninistr. 15, 81377, Munich (Germany); Dietrich, O.; Flatz, W.; Ertl-Wagner, B. [University of Munich, Institute of Clinical Radiology, Grosshadern Medical Centre, Munich (Germany); Keeser, D. [University of Munich, Institute of Clinical Radiology, Grosshadern Medical Centre, Munich (Germany); University of Munich, German Centre for Vertigo and Balance Disorders, Grosshadern Medical Centre, Marchioninistr. 15, 81377, Munich (Germany); University of Munich, Department of Psychiatry and Psychotherapy, Innenstadtkliniken Medical Centre, Munich (Germany)

    2014-10-16

    We aimed to volumetrically quantify endolymph and perilymph spaces of the inner ear in order to establish a methodological basis for further investigations into the pathophysiology and therapeutic monitoring of Meniere's disease. Sixteen patients (eight females, aged 38-71 years) with definite unilateral Meniere's disease were included in this study. Magnetic resonance (MR) cisternography with a T2-SPACE sequence was combined with a Real reconstruction inversion recovery (Real-IR) sequence for delineation of inner ear fluid spaces. Machine learning and automated local thresholding segmentation algorithms were applied for three-dimensional (3D) reconstruction and volumetric quantification of endolymphatic hydrops. Test-retest reliability was assessed by the intra-class coefficient; correlation of cochlear endolymph volume ratio with hearing function was assessed by the Pearson correlation coefficient. Endolymph volume ratios could be reliably measured in all patients, with a mean (range) value of 15 % (2-25) for the cochlea and 28 % (12-40) for the vestibulum. Test-retest reliability was excellent, with an intra-class coefficient of 0.99. Cochlear endolymphatic hydrops was significantly correlated with hearing loss (r = 0.747, p = 0.001). MR imaging after local contrast application and image processing, including machine learning and automated local thresholding, enable the volumetric quantification of endolymphatic hydrops. This allows for a quantitative assessment of the effect of therapeutic interventions on endolymphatic hydrops. (orig.)

  6. Point Coupled Displacement Sensor Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Real-time displacement measurement techniques are needed to acquire aerodynamic and structural system characteristics in flight. This proposal describes the...

  7. Dispossession and displacement in Libya

    Directory of Open Access Journals (Sweden)

    Rhodri C Williams

    2012-06-01

    Full Text Available Inability to access pre-displacement housing, land and property poses a significant obstacle to the achievement of durable solutions for most IDPs in Libya. Displacement and dispossession cannot be separated from the legacy of the Gaddafi era.

  8. Displacement, Substitution, Sublimation: A Bibliography.

    Science.gov (United States)

    Pedrini, D. T.; Pedrini, Bonnie C.

    Sigmund Freund worked with the mechanisms of displacement, substitution, and sublimation. These mechanisms have many similarities and have been studied diagnostically and therapeutically. Displacement and substitution seem to fit in well with phobias, hysterias, somatiyations, prejudices, and scapegoating. Phobias, prejudices, and scapegoating…

  9. Volumetric polymerization shrinkage of contemporary composite resins

    Directory of Open Access Journals (Sweden)

    Halim Nagem Filho

    2007-10-01

    Full Text Available The polymerization shrinkage of composite resins may affect negatively the clinical outcome of the restoration. Extensive research has been carried out to develop new formulations of composite resins in order to provide good handling characteristics and some dimensional stability during polymerization. The purpose of this study was to analyze, in vitro, the magnitude of the volumetric polymerization shrinkage of 7 contemporary composite resins (Definite, Suprafill, SureFil, Filtek Z250, Fill Magic, Alert, and Solitaire to determine whether there are differences among these materials. The tests were conducted with precision of 0.1 mg. The volumetric shrinkage was measured by hydrostatic weighing before and after polymerization and calculated by known mathematical equations. One-way ANOVA (a or = 0.05 was used to determine statistically significant differences in volumetric shrinkage among the tested composite resins. Suprafill (1.87±0.01 and Definite (1.89±0.01 shrank significantly less than the other composite resins. SureFil (2.01±0.06, Filtek Z250 (1.99±0.03, and Fill Magic (2.02±0.02 presented intermediate levels of polymerization shrinkage. Alert and Solitaire presented the highest degree of polymerization shrinkage. Knowing the polymerization shrinkage rates of the commercially available composite resins, the dentist would be able to choose between using composite resins with lower polymerization shrinkage rates or adopting technical or operational procedures to minimize the adverse effects deriving from resin contraction during light-activation.

  10. A SUBDIVISION SCHEME FOR VOLUMETRIC MODELS

    Institute of Scientific and Technical Information of China (English)

    GhulamMustafa; LiuXuefeng

    2005-01-01

    In this paper, a subdivision scheme which generalizes a surface scheme in previous papers to volume meshes is designed. The scheme exhibits significant control over shrink-age/size of volumetric models. It also has the ability to conveniently incorporate boundaries and creases into a smooth limit shape of models. The method presented here is much simpler and easier as compared to MacCracken and Joy's. This method makes no restrictions on the local topology of meshes. Particularly, it can be applied without any change to meshes of nonmanifold topology.

  11. Volumetric composition in composites and historical data

    DEFF Research Database (Denmark)

    Lilholt, Hans; Madsen, Bo

    2013-01-01

    guidance to the optimal combination of fibre content, matrix content and porosity content, in order to achieve the best obtainable properties. Several composite materials systems have been shown to be handleable with this model. An extensive series of experimental data for the system of cellulose fibres...... and polymer (resin) was produced in 1942 – 1944, and these data have been (re-)analysed by the volumetric composition model, and the property values for density, stiffness and strength have been evaluated. Good agreement has been obtained and some further observations have been extracted from the analysis....

  12. IMITATION OF STANDARD VOLUMETRIC ACTIVITY METAL SAMPLES

    Directory of Open Access Journals (Sweden)

    A. I. Zhukouski

    2016-01-01

    Full Text Available Due to the specific character of problems in the field of ionizing radiation spectroscopy, the R&D and making process of standard volumetric activity metal samples (standard samples for calibration and verification of spectrometric equipment is not only expensive, but also requires the use of highly qualified experts and a unique specific equipment. Theoretical and experimental studies performed have shown the possibility to use imitators as a set of alternating point sources of gamma radiation and metal plates and their use along with standard volumetric activity metal samples for calibration of scintillation-based detectors used in radiation control in metallurgy. Response functions or instrumental spectra of such spectrometer to radionuclides like 137Cs, 134Cs, 152Eu, 154Eu, 60Co, 54Mn, 232Th, 226Ra, 65Zn, 125Sb+125mTe, 106Ru+106Rh, 94Nb, 110mAg, 233U, 234U, 235U and 238U are required for calibration in a given measurement geometry. Standard samples in the form of a probe made of melt metal of a certain diameter and height are used in such measurements. However, the production of reference materials is costly and even problematic for such radionuclides as 94Nb, 125Sb+125mTe, 234U, 235U  etc. A recognized solution to solve this problem is to use the Monte-Carlo simulation method. Instrumental experimental and theoretical spectra obtained by using standard samples and their imitators show a high compliance between experimental spectra of real samples and the theoretical ones of their Monte-Carlo models, between spectra of real samples and the ones of their imitators and finally, between experimental spectra of real sample imitators and the theoretical ones of their Monte-Carlo models. They also have shown the adequacy and consistency of the approach in using a combination of metal scattering layers and reference point gamma-ray sources instead of standard volumetric activity metal samples. As for using several reference point gamma-ray sources

  13. Magnetic volumetric hologram memory with magnetic garnet.

    Science.gov (United States)

    Nakamura, Yuichi; Takagi, Hiroyuki; Lim, Pang Boey; Inoue, Mitsuteru

    2014-06-30

    Holographic memory is a promising next-generation optical memory that has a higher recording density and a higher transfer rate than other types of memory. In holographic memory, magnetic garnet films can serve as rewritable holographic memory media by use of magneto-optical effect. We have now demonstrated that a magnetic hologram can be recorded volumetrically in a ferromagnetic garnet film and that the signal image can be reconstructed from it for the first time. In addition, multiplicity of the magnetic hologram was also confirmed; the image could be reconstructed from a spot overlapped by other spots.

  14. OIL DISPLACEMENT IN MISCIBLE CONDITION

    Directory of Open Access Journals (Sweden)

    Ivanka Juttner

    1997-12-01

    Full Text Available After primary oil recovery in reservoirs remains about 70% of unexploited oil. To improve the recovery of the remaining reserves, injection of a fluid provide the extra energy in a mchunical form. Oil displacement can he achieved by gas injection of lean natural gas, mainly methane, carbon dioxide etc. Oil displacement can be in immiscible or miscible conditions. This paper deals with mechanism of miscible gas drive. On the basis of simulation of the oil displacement process by gas injection into oil field Žutica the character of process, i. c. a degree of miscibility or immiscibility between the injected fluid and reservoir oil was determined.

  15. Internal displacement in eastern Burma

    OpenAIRE

    Heather Rae

    2007-01-01

    The history of post-independent Burma is characterisedby numerous conflicts in this extraordinarily heterogeneous country. Since military rule began in 196 2 Burmahas witnessed gross human rights abuses andmassive displacement.

  16. Internal displacement in eastern Burma

    Directory of Open Access Journals (Sweden)

    Heather Rae

    2007-07-01

    Full Text Available The history of post-independent Burma is characterisedby numerous conflicts in this extraordinarily heterogeneous country. Since military rule began in 196 2 Burmahas witnessed gross human rights abuses andmassive displacement.

  17. To prevent or pursue displacement?

    OpenAIRE

    2012-01-01

    The repertoire of survival actions of at-risk civilians includes bothavoiding and attempting displacement. But there are also overlaps,combinations and tacking back and forth between the two, whiletrying to mitigate the risks that any choice entails.

  18. Disentangling volumetric and hydrational properties of proteins.

    Science.gov (United States)

    Voloshin, Vladimir P; Medvedev, Nikolai N; Smolin, Nikolai; Geiger, Alfons; Winter, Roland

    2015-02-05

    We used molecular dynamics simulations of a typical monomeric protein, SNase, in combination with Voronoi-Delaunay tessellation to study and analyze the temperature dependence of the apparent volume, Vapp, of the solute. We show that the void volume, VB, created in the boundary region between solute and solvent, determines the temperature dependence of Vapp to a major extent. The less pronounced but still significant temperature dependence of the molecular volume of the solute, VM, is essentially the result of the expansivity of its internal voids, as the van der Waals contribution to VM is practically independent of temperature. Results for polypeptides of different chemical nature feature a similar temperature behavior, suggesting that the boundary/hydration contribution seems to be a universal part of the temperature dependence of Vapp. The results presented here shine new light on the discussion surrounding the physical basis for understanding and decomposing the volumetric properties of proteins and biomolecules in general.

  19. All Photons Imaging Through Volumetric Scattering

    Science.gov (United States)

    Satat, Guy; Heshmat, Barmak; Raviv, Dan; Raskar, Ramesh

    2016-01-01

    Imaging through thick highly scattering media (sample thickness ≫ mean free path) can realize broad applications in biomedical and industrial imaging as well as remote sensing. Here we propose a computational “All Photons Imaging” (API) framework that utilizes time-resolved measurement for imaging through thick volumetric scattering by using both early arrived (non-scattered) and diffused photons. As opposed to other methods which aim to lock on specific photons (coherent, ballistic, acoustically modulated, etc.), this framework aims to use all of the optical signal. Compared to conventional early photon measurements for imaging through a 15 mm tissue phantom, our method shows a two fold improvement in spatial resolution (4db increase in Peak SNR). This all optical, calibration-free framework enables widefield imaging through thick turbid media, and opens new avenues in non-invasive testing, analysis, and diagnosis. PMID:27683065

  20. Optimal smoothing length scale for actuator line models of wind turbine blades based on Gaussian body force distribution: Wind energy, actuator line model

    Energy Technology Data Exchange (ETDEWEB)

    Martínez-Tossas, L. A. [Department of Mechanical Engineering, Johns Hopkins University, Baltimore 21218 MD USA; Churchfield, M. J. [National Renewable Energy Laboratory, Golden 80401 CO USA; Meneveau, C. [Department of Mechanical Engineering, Johns Hopkins University, Baltimore 21218 MD USA

    2017-01-20

    The actuator line model (ALM) is a commonly used method to represent lifting surfaces such as wind turbine blades within large-eddy simulations (LES). In the ALM, the lift and drag forces are replaced by an imposed body force that is typically smoothed over several grid points using a Gaussian kernel with some prescribed smoothing width e. To date, the choice of e has most often been based on numerical considerations related to the grid spacing used in LES. However, especially for finely resolved LES with grid spacings on the order of or smaller than the chord length of the blade, the best choice of e is not known. In this work, a theoretical approach is followed to determine the most suitable value of e, based on an analytical solution to the linearized inviscid flow response to a Gaussian force. We find that the optimal smoothing width eopt is on the order of 14%-25% of the chord length of the blade, and the center of force is located at about 13%-26% downstream of the leading edge of the blade for the cases considered. These optimal values do not depend on angle of attack and depend only weakly on the type of lifting surface. It is then shown that an even more realistic velocity field can be induced by a 2-D elliptical Gaussian lift-force kernel. Some results are also provided regarding drag force representation.

  1. A Technique for Volumetric CSG Based on Morphology

    DEFF Research Database (Denmark)

    Bærentzen, Jakob Andreas; Christensen, Niels Jørgen

    2001-01-01

    In this paper, a new technique for volumetric CSG is presented. The technique requires the input volumes to correspond to solids which fulfill a voxelization suitability criterion. Assume the CSG operation is union. The volumetric union of two such volumes is defined in terms of the voxelization...

  2. Displacement currents in geoelectromagnetic problems

    Science.gov (United States)

    Mogilatov, Vladimir; Goldman, Mark; Persova, Marina; Soloveichik, Yury

    2014-06-01

    The influence of displacement currents in conventional geoelectromagnetic (GEM) methods using unimodal transversal electric (TE) or multimodal TE and TM (transversal magnetic) fields is only significant at very high frequencies in the frequency domain or at extremely early times in the time domain. The transient process in the latter includes three stages: the propagation through air, the propagation through earth and the diffusion within the earth. The influence of displacement currents is significant mainly during the former two stages, normally up to several tens to a few hundreds of nanoseconds. The behavior is essentially different in novel GEM methods using a vertical electric dipole (VED) or circular electric dipole (CED) sources of unimodal TM-fields. Under certain geoelectric conditions, the influence of displacement currents in these methods might be crucial at late times as well. This happens, if the model consists of insulating layers. In the absence of displacement currents, such layers would totally mask underlying structures. However, TM-fields including displacement currents depend on geoelectric parameters below insulating layers at late times.

  3. Formation around planetary displaced orbit

    Institute of Scientific and Technical Information of China (English)

    GONG Sheng-ping; LI Jun-feng; BAOYIN He-xi

    2007-01-01

    The paper investigates the relative motion around the planetary displaced orbit. Several kinds of displaced orbits for geocentric and martian cases were discussed. First, the relative motion was linearized around the displaced orbits. Then, two seminatural control laws were investigated for each kind of orbit and the stable regions were obtained for each case. One of the two control laws is the passive control law that is very attractive for engineering practice. However, the two control laws are not very suitable for the Martian mission. Another special semi-natural control law is designed based on the requirement of the Martian mission. The results show that large stable regions exist for the control law.

  4. Perceived Displacement explains Wolfpack Effect

    Directory of Open Access Journals (Sweden)

    Matúš eŠimkovic

    2014-12-01

    Full Text Available We investigate the influence of perceived displacement of moving agent-like stimuli on the performance in dynamic interactive tasks. In order to reliably measure perceived displacement we utilize multiple tasks with different task demands. The perceived center of an agent’s body is displaced in the direction in which the agent is facing and this perceived displacement is larger than the theoretical position of the center of mass would predict. Furthermore, the displacement in the explicit judgment is dissociated from the displacement obtained by the implicit measures. By manipulating the location of the pivot point, we show that it is not necessary to postulate orientation as an additional cue utilized by perception, as has been suggested by earlier studies. These studies showed that the agent’s orientation influences the detection of chasing motion and the detection-related performance in interactive tasks. This influence has been labeled wolfpack effect. In one of the demonstrations of the wolfpack effect participants control a green circle on a display with a computer mouse. It has been shown that participants avoid display areas withagents pointing towards the green circle. Participants do so in favor of areas where the agents point in the direction perpendicular to the circle. We show that this avoidance behavior arises because the agent’s pivot point selected by the earlier studies is different from where people locate the center of agent’s body. As a consequence, the nominal rotation confounds rotation and translation. We show that the avoidance behavior disappears once the pivot point is set to the center of agent’s body.

  5. Displacement ventilation in lecture halls

    OpenAIRE

    Egorov, Artem

    2013-01-01

    This thesis considers several important goals. The main purpose is to see how displacement ventilation sys-tem works in the lecture hall of M-building and compare obtained results with D2 and Indoor Climate Classi-fication. The second one is to analyze the function of the ventilation system. The last one is to realize when displacement ventilation is preferable to mixing ventilation. Analysis of the system was carried out with instruments from MUAS HVAC laboratory. In lecture hall were me...

  6. Displaced plaque in retroperitoneal adenopathy.

    Science.gov (United States)

    Al-Okaili, Riyadh N; Schable, Stephen I; Marlow, Troy J

    2002-08-01

    This study was designed to determine when to consider incidental retroperitoneal masses on the basis of a displaced calcified atheromatous abdominal aorta on lateral radiographs. We did a retrospective review of 143 normal abdominal helical computed tomography scans of individuals aged 50 years and older to measure the distance between the posterior aortic wall and anterior cortex of vertebral bodies from T12 through L3. The normal abdominal aorta maintains a close relationship to the vertebral column. The distance should not be more than 10 mm in men and 7.3 mm in women. Displacement of aortic calcified atheroma greater than these distances should prompt a search for a retroperitoneal mass.

  7. Displacement and difference in Lubumbashi

    Directory of Open Access Journals (Sweden)

    Aurelia Wa Kabwe-Segatti

    2007-01-01

    Full Text Available Signs on the outskirts of the second largest city in the Democratic Republic of Congo (DRC welcome visitors to ‘the city of peace’. Lubumbashi has a reputation as a haven of tolerance in a violent nation but how are displaced people treated?

  8. To prevent or pursue displacement?

    Directory of Open Access Journals (Sweden)

    Casey Barrs

    2012-12-01

    Full Text Available The repertoire of survival actions of at-risk civilians includes bothavoiding and attempting displacement. But there are also overlaps,combinations and tacking back and forth between the two, whiletrying to mitigate the risks that any choice entails.

  9. DISPLACEMENT BASED SEISMIC DESIGN METHODS.

    Energy Technology Data Exchange (ETDEWEB)

    HOFMAYER,C.MILLER,C.WANG,Y.COSTELLO,J.

    2003-07-15

    A research effort was undertaken to determine the need for any changes to USNRC's seismic regulatory practice to reflect the move, in the earthquake engineering community, toward using expected displacement rather than force (or stress) as the basis for assessing design adequacy. The research explored the extent to which displacement based seismic design methods, such as given in FEMA 273, could be useful for reviewing nuclear power stations. Two structures common to nuclear power plants were chosen to compare the results of the analysis models used. The first structure is a four-story frame structure with shear walls providing the primary lateral load system, referred herein as the shear wall model. The second structure is the turbine building of the Diablo Canyon nuclear power plant. The models were analyzed using both displacement based (pushover) analysis and nonlinear dynamic analysis. In addition, for the shear wall model an elastic analysis with ductility factors applied was also performed. The objectives of the work were to compare the results between the analyses, and to develop insights regarding the work that would be needed before the displacement based analysis methodology could be considered applicable to facilities licensed by the NRC. A summary of the research results, which were published in NUREGICR-6719 in July 2001, is presented in this paper.

  10. Planning strategies in volumetric modulated are therapy for breast.

    Science.gov (United States)

    Giorgia, Nicolini; Antonella, Fogliata; Alessandro, Clivio; Eugenio, Vanetti; Luca, Cozzi

    2011-07-01

    In breast radiotherapy with intensity modulation, it is a well established practice to extend the dose fluence outside the limit of the body contour to account for small changes in size and position of the target and the rest of the tissues due to respiration or to possible oedema. A simple approach is not applicable with RapidArc volumetric modulated are therapy not being based on a fixed field fluence delivery. In this study, a viable technical strategy to account for this need is presented. RapidArc (RA) plans for six breast cancer patients (three right and three left cases), were optimized (PRO version III) on the original CT data set (0) and on an alternative CT (E) generated with an artificial expansion (and assignment of soft-tissue equivalent HU) of 10 mm of the body in the breast region and of the PTV contours toward the external direction. Final dose calculations for the two set of plans were performed on the same original CT data set O, normalizing the dose prescription (50 Gy) to the target mean. In this way, two treatment plans on the same CT set O for each patient were obtained: the no action plan (OO) and the alternative plan based on an expanded optimization (EO). Fixing MU, these two plans were then recomputed on the expanded CT data set and on an intermediate one (with expansion = 5 mm), to mimic, possible changes in size due to edema during treatment or residual displacements due to breathing not properly controlled. Aim of the study was to quantify the robustness of this planning strategy on dose distributions when either the OO or the EO strategies were adopted. For all the combinations, a DVH analysis of all involved structures is reported. I. The two optimization approaches gave comparable dose distributions on the original CT data set. II. When plans were evaluated on the expanded CTs (mimicking the presence of edema), the EO approach showed improved target coverage if compared to OO: on CT_10 mm, Dv = 98% [%]= 92.5 +/- 0.9 and 68.5 +/- 3

  11. Planning strategies in volumetric modulated arc therapy for breast.

    Science.gov (United States)

    Nicolini, Giorgia; Fogliata, Antonella; Clivio, Alessandro; Vanetti, Eugenio; Cozzi, Luca

    2011-07-01

    In breast radiotherapy with intensity modulation, it is a well established practice to extend the dose fluence outside the limit of the body contour to account for small changes in size and position of the target and the rest of the tissues due to respiration or to possible oedema. A simple approach is not applicable with RapidArc volumetric modulated arc therapy not being based on a fixed field fluence delivery. In this study, a viable technical strategy to account for this need is presented. RapidArc (RA) plans for six breast cancer patients (three right and three left cases), were optimized (PRO version III) on the original CT data set (O) and on an alternative CT (E) generated with an artificial expansion (and assignment of soft-tissue equivalent HU) of 10 mm of the body in the breast region and of the PTV contours toward the external direction. Final dose calculations for the two set of plans were performed on the same original CT data set O, normalizing the dose prescription (50 Gy) to the target mean. In this way, two treatment plans on the same CT set O for each patient were obtained: the no action plan (OO) and the alternative plan based on an expanded optimization (EO). Fixing MU, these two plans were then recomputed on the expanded CT data set and on an intermediate one (with expansion = 5 mm), to mimic, possible changes in size due to edema during treatment or residual displacements due to breathing not properly controlled. Aim of the study was to quantify the robustness of this planning strategy on dose distributions when either the OO or the EO strategies were adopted. For all the combinations, a DVH analysis of all involved structures is reported. I. The two optimization approaches gave comparable dose distributions on the original CT data set. II. When plans were evaluated on the expanded CTs (mimicking the presence of edema), the EO approach showed improved target coverage if compared to OO: on CT_10 mm, DV = 98% [%] = 92.5 ± 0

  12. DEVELOPMENT OF POLYMER GEL SYSTEMS TO IMPROVE VOLUMETRIC SWEEP AND REDUCE PRODUCING WATER/OIL RATIOS

    Energy Technology Data Exchange (ETDEWEB)

    G. Paul Willhite; Don W. Green; Stan McCool; Min Cheng; Feiyan Chen

    2004-02-01

    The objectives of the research are to improve the effectiveness of polymer gels to increase volumetric sweep efficiency of fluid displacement processes and to reduce water production in production wells. The research is based on experimental data and conceptual and mathematical models developed from interpretation of experimental data. This report describes two types of mathematical models that were developed. One model type simulates the chemical reactions where polymer molecules are crosslinked to form a 3-dimensional network or gel. The model is based on statistical probabilities of reactions and yields molecular weights averages and distributions as functions of conversion. The second model type simulates the transport of chromium acetate, a common polymer crosslinker, through porous dolomite rock and includes the mechanisms of dolomite dissolution and chromium precipitation. The chromium transport model reasonably agreed with experimental data.

  13. Volumetrics of CO{sub 2} Storage in Deep Saline Formations

    Energy Technology Data Exchange (ETDEWEB)

    Steele-MacInnis, Matthew; Capobianco, Ryan M; Dilmore, Robert; Goodman, Angela; Guthrie, George; Rimstidt, J Donald; Bodnar, Robert J

    2013-01-01

    Concern about the role of greenhouse gases in global climate change has generated interest in sequestering CO{sub 2} from fossil-fuel combustion in deep saline formations. Pore space in these formations is initially filled with brine, and space to accommodate injected CO{sub 2} must be generated by displacing brine, and to a lesser extent by compression of brine and rock. The formation volume required to store a given mass of CO{sub 2} depends on the storage mechanism. We compare the equilibrium volumetric requirements of three end-member processes: CO{sub 2} stored as a supercritical fluid (structural or stratigraphic trapping); CO{sub 2} dissolved in pre-existing brine (solubility trapping); and CO{sub 2} solubility enhanced by dissolution of calcite. For typical storage conditions, storing CO{sub 2} by solubility trapping reduces the volume required to store the same amount of CO{sub 2} by structural or stratigraphic trapping by about 50%. Accessibility of CO{sub 2} to brine determines which storage mechanism (structural/stratigraphic versus solubility) dominates at a given time, which is a critical factor in evaluating CO{sub 2} volumetric requirements and long-term storage security.

  14. Soil volumetric water content measurements using TDR technique

    Directory of Open Access Journals (Sweden)

    S. Vincenzi

    1996-06-01

    Full Text Available A physical model to measure some hydrological and thermal parameters in soils will to be set up. The vertical profiles of: volumetric water content, matric potential and temperature will be monitored in different soils. The volumetric soil water content is measured by means of the Time Domain Reflectometry (TDR technique. The result of a test to determine experimentally the reproducibility of the volumetric water content measurements is reported together with the methodology and the results of the analysis of the TDR wave forms. The analysis is based on the calculation of the travel time of the TDR signal in the wave guide embedded in the soil.

  15. Iterative reconstruction of volumetric particle distribution

    Science.gov (United States)

    Wieneke, Bernhard

    2013-02-01

    For tracking the motion of illuminated particles in space and time several volumetric flow measurement techniques are available like 3D-particle tracking velocimetry (3D-PTV) recording images from typically three to four viewing directions. For higher seeding densities and the same experimental setup, tomographic PIV (Tomo-PIV) reconstructs voxel intensities using an iterative tomographic reconstruction algorithm (e.g. multiplicative algebraic reconstruction technique, MART) followed by cross-correlation of sub-volumes computing instantaneous 3D flow fields on a regular grid. A novel hybrid algorithm is proposed here that similar to MART iteratively reconstructs 3D-particle locations by comparing the recorded images with the projections calculated from the particle distribution in the volume. But like 3D-PTV, particles are represented by 3D-positions instead of voxel-based intensity blobs as in MART. Detailed knowledge of the optical transfer function and the particle image shape is mandatory, which may differ for different positions in the volume and for each camera. Using synthetic data it is shown that this method is capable of reconstructing densely seeded flows up to about 0.05 ppp with similar accuracy as Tomo-PIV. Finally the method is validated with experimental data.

  16. Interplay between interstitial displacement and displacive lattice transformations

    Science.gov (United States)

    Zhang, Xie; Hickel, Tilmann; Rogal, Jutta; Neugebauer, Jörg

    2016-09-01

    Diffusionless displacive lattice rearrangements, which include martensitic transformations, are in real materials often accompanied by a displacive drag of interstitials. The interplay of both processes leads to a particular atomistic arrangement of the interstitials in the product phase, which is decisive for its performance. An archetype example is the martensitic transformation in Fe-C alloys. One of the puzzles for this system is that the deviation from the cubic symmetry (i.e., the tetragonality) in the martensite resulting from this interplay is lower than what thermodynamics dictates. In our ab initio approach, the relative motion of C in the transforming lattice is studied with the nudged elastic band method. We prove that an atomic shearlike shuffle mechanism of adjacent (11 2 ¯) Fe layers along the ±[111] bcc directions is essential to achieve a redistribution of C atoms during the fcc → bcc transition, which fully explains the abnormal behavior. Furthermore, the good agreement with experiment validates our method to treat a diffusionless redistribution of interstitials and a displacive rearrangement of the host lattice simultaneously.

  17. Volumetric particle image velocimetry with a single plenoptic camera

    Science.gov (United States)

    Fahringer, Timothy W.; Lynch, Kyle P.; Thurow, Brian S.

    2015-11-01

    A novel three-dimensional (3D), three-component (3C) particle image velocimetry (PIV) technique based on volume illumination and light field imaging with a single plenoptic camera is described. A plenoptic camera uses a densely packed microlens array mounted near a high resolution image sensor to sample the spatial and angular distribution of light collected by the camera. The multiplicative algebraic reconstruction technique (MART) computed tomography algorithm is used to reconstruct a volumetric intensity field from individual snapshots and a cross-correlation algorithm is used to estimate the velocity field from a pair of reconstructed particle volumes. This work provides an introduction to the basic concepts of light field imaging with a plenoptic camera and describes the unique implementation of MART in the context of plenoptic image data for 3D/3C PIV measurements. Simulations of a plenoptic camera using geometric optics are used to generate synthetic plenoptic particle images, which are subsequently used to estimate the quality of particle volume reconstructions at various particle number densities. 3D reconstructions using this method produce reconstructed particles that are elongated by a factor of approximately 4 along the optical axis of the camera. A simulated 3D Gaussian vortex is used to test the capability of single camera plenoptic PIV to produce a 3D/3C vector field, where it was found that lateral displacements could be measured to approximately 0.2 voxel accuracy in the lateral direction and 1 voxel in the depth direction over a 300× 200× 200 voxel volume. The feasibility of the technique is demonstrated experimentally using a home-built plenoptic camera based on a 16-megapixel interline CCD camera and a 289× 193 array of microlenses and a pulsed Nd:YAG laser. 3D/3C measurements were performed in the wake of a low Reynolds number circular cylinder and compared with measurements made using a conventional 2D/2C PIV system. Overall, single camera

  18. Characterizing volumetric deformation behavior of naturally occuring bituminous sand materials

    CSIR Research Space (South Africa)

    Anochie-Boateng, Joseph

    2009-05-01

    Full Text Available newly proposed hydrostatic compression test procedure. The test procedure applies field loading conditions of off-road construction and mining equipment to closely simulate the volumetric deformation and stiffness behaviour of oil sand materials. Based...

  19. Hyperspectral image classification based on volumetric texture and dimensionality reduction

    Science.gov (United States)

    Su, Hongjun; Sheng, Yehua; Du, Peijun; Chen, Chen; Liu, Kui

    2015-06-01

    A novel approach using volumetric texture and reduced-spectral features is presented for hyperspectral image classification. Using this approach, the volumetric textural features were extracted by volumetric gray-level co-occurrence matrices (VGLCM). The spectral features were extracted by minimum estimated abundance covariance (MEAC) and linear prediction (LP)-based band selection, and a semi-supervised k-means (SKM) clustering method with deleting the worst cluster (SKMd) bandclustering algorithms. Moreover, four feature combination schemes were designed for hyperspectral image classification by using spectral and textural features. It has been proven that the proposed method using VGLCM outperforms the gray-level co-occurrence matrices (GLCM) method, and the experimental results indicate that the combination of spectral information with volumetric textural features leads to an improved classification performance in hyperspectral imagery.

  20. Designing remote web-based mechanical-volumetric flow meter ...

    African Journals Online (AJOL)

    ... remote web-based mechanical-volumetric flow meter reading systems based on ... damage and also provides the ability to control and manage consumption. ... existing infrastructure of the telecommunications is used in data transmission.

  1. Increasing the volumetric efficiency of Diesel engines by intake pipes

    Science.gov (United States)

    List, Hans

    1933-01-01

    Development of a method for calculating the volumetric efficiency of piston engines with intake pipes. Application of this method to the scavenging pumps of two-stroke-cycle engines with crankcase scavenging and to four-stroke-cycle engines. The utility of the method is demonstrated by volumetric-efficiency tests of the two-stroke-cycle engines with crankcase scavenging. Its practical application to the calculation of intake pipes is illustrated by example.

  2. Serial volumetric registration of pulmonary CT studies

    Science.gov (United States)

    Silva, José Silvestre; Silva, Augusto; Sousa Santos, Beatriz

    2008-03-01

    Detailed morphological analysis of pulmonary structures and tissue, provided by modern CT scanners, is of utmost importance as in the case of oncological applications both for diagnosis, treatment, and follow-up. In this case, a patient may go through several tomographic studies throughout a period of time originating volumetric sets of image data that must be appropriately registered in order to track suspicious radiological findings. The structures or regions of interest may change their position or shape in CT exams acquired at different moments, due to postural, physiologic or pathologic changes, so, the exams should be registered before any follow-up information can be extracted. Postural mismatching throughout time is practically impossible to avoid being particularly evident when imaging is performed at the limiting spatial resolution. In this paper, we propose a method for intra-patient registration of pulmonary CT studies, to assist in the management of the oncological pathology. Our method takes advantage of prior segmentation work. In the first step, the pulmonary segmentation is performed where trachea and main bronchi are identified. Then, the registration method proceeds with a longitudinal alignment based on morphological features of the lungs, such as the position of the carina, the pulmonary areas, the centers of mass and the pulmonary trans-axial principal axis. The final step corresponds to the trans-axial registration of the corresponding pulmonary masked regions. This is accomplished by a pairwise sectional registration process driven by an iterative search of the affine transformation parameters leading to optimal similarity metrics. Results with several cases of intra-patient, intra-modality registration, up to 7 time points, show that this method provides accurate registration which is needed for quantitative tracking of lesions and the development of image fusion strategies that may effectively assist the follow-up process.

  3. Volumetric optoacoustic monitoring of endovenous laser treatments

    Science.gov (United States)

    Fehm, Thomas F.; Deán-Ben, Xosé L.; Schaur, Peter; Sroka, Ronald; Razansky, Daniel

    2016-03-01

    Chronic venous insufficiency (CVI) is one of the most common medical conditions with reported prevalence estimates as high as 30% in the adult population. Although conservative management with compression therapy may improve the symptoms associated with CVI, healing often demands invasive procedures. Besides established surgical methods like vein stripping or bypassing, endovenous laser therapy (ELT) emerged as a promising novel treatment option during the last 15 years offering multiple advantages such as less pain and faster recovery. Much of the treatment success hereby depends on monitoring of the treatment progression using clinical imaging modalities such as Doppler ultrasound. The latter however do not provide sufficient contrast, spatial resolution and three-dimensional imaging capacity which is necessary for accurate online lesion assessment during treatment. As a consequence, incidence of recanalization, lack of vessel occlusion and collateral damage remains highly variable among patients. In this study, we examined the capacity of volumetric optoacoustic tomography (VOT) for real-time monitoring of ELT using an ex-vivo ox foot model. ELT was performed on subcutaneous veins while optoacoustic signals were acquired and reconstructed in real-time and at a spatial resolution in the order of 200μm. VOT images showed spatio-temporal maps of the lesion progression, characteristics of the vessel wall, and position of the ablation fiber's tip during the pull back. It was also possible to correlate the images with the temperature elevation measured in the area adjacent to the ablation spot. We conclude that VOT is a promising tool for providing online feedback during endovenous laser therapy.

  4. Treatment planning for volumetric modulated arc therapy

    Energy Technology Data Exchange (ETDEWEB)

    Bedford, James L. [Joint Department of Physics, Institute of Cancer Research and The Royal Marsden NHS Foundation Trust, Downs Road, Sutton, Surrey SM2 5PT (United Kingdom)

    2009-11-15

    Purpose: Volumetric modulated arc therapy (VMAT) is a specific type of intensity-modulated radiation therapy (IMRT) in which the gantry speed, multileaf collimator (MLC) leaf position, and dose rate vary continuously during delivery. A treatment planning system for VMAT is presented. Methods: Arc control points are created uniformly throughout one or more arcs. An iterative least-squares algorithm is used to generate a fluence profile at every control point. The control points are then grouped and all of the control points in a given group are used to approximate the fluence profiles. A direct-aperture optimization is then used to improve the solution, taking into account the allowed range of leaf motion of the MLC. Dose is calculated using a fast convolution algorithm and the motion between control points is approximated by 100 interpolated dose calculation points. The method has been applied to five cases, consisting of lung, rectum, prostate and seminal vesicles, prostate and pelvic lymph nodes, and head and neck. The resulting plans have been compared with segmental (step-and-shoot) IMRT and delivered and verified on an Elekta Synergy to ensure practicality. Results: For the lung, prostate and seminal vesicles, and rectum cases, VMAT provides a plan of similar quality to segmental IMRT but with faster delivery by up to a factor of 4. For the prostate and pelvic nodes and head-and-neck cases, the critical structure doses are reduced with VMAT, both of these cases having a longer delivery time than IMRT. The plans in general verify successfully, although the agreement between planned and measured doses is not very close for the more complex cases, particularly the head-and-neck case. Conclusions: Depending upon the emphasis in the treatment planning, VMAT provides treatment plans which are higher in quality and/or faster to deliver than IMRT. The scheme described has been successfully introduced into clinical use.

  5. Single-mode displacement sensor

    Science.gov (United States)

    Duivenvoorden, Kasper; Terhal, Barbara M.; Weigand, Daniel

    2017-01-01

    We show that one can determine both parameters of a displacement acting on an oscillator with an accuracy which scales inversely with the square root of the number of photons in the oscillator. Our results are obtained by using a grid state as a sensor state for detecting small translations in phase space (displacements). Grid states were first proposed [D. Gottesman et al., Phys. Rev. A 64, 012310 (2001), 10.1103/PhysRevA.64.012310] for encoding a qubit into an oscillator: an efficient preparation protocol of such states, using a coupling to a qubit, was later developed [B. M. Terhal and D. Weigand, Phys. Rev. A 93, 012315 (2016), 10.1103/PhysRevA.93.012315]. We compare the performance of the grid state with the quantum compass or cat code state and place our results in the context of the two-parameter quantum Cramér-Rao lower bound on the variances of the displacement parameters. We show that the accessible information about the displacement for a grid state increases with the number of photons in the state when we measure and prepare the state using a phase estimation protocol. This is in contrast with the accessible information in the quantum compass state which we show is always upper bounded by a constant, independent of the number of photons. We present numerical simulations of a phase estimation based preparation protocol of a grid state in the presence of photon loss, nonlinearities, and qubit measurement, using no post-selection, showing how the two effective squeezing parameters which characterize the grid state change during the preparation. The idea behind the phase estimation protocol is a simple maximal-information gain strategy.

  6. Internal Displaced People i Colombia

    OpenAIRE

    Gustafsen, Rune Rud

    2012-01-01

    This thesis investigates weather or not the formation and consolidation of peace communities in rural Colombia represent an alternative in the Internal Displaced People´s (IDP) search for sustainable livelihoods in a context highly influenced by on one hand the waging war between primarily FARC and the Colombian state and on the other the violent consequences of the evolved drug production which is influencing all levels of Colombian society. The IDP population in Colombia is according to ...

  7. Visualization and volumetric structures from MR images of the brain

    Energy Technology Data Exchange (ETDEWEB)

    Parvin, B.; Johnston, W.; Robertson, D.

    1994-03-01

    Pinta is a system for segmentation and visualization of anatomical structures obtained from serial sections reconstructed from magnetic resonance imaging. The system approaches the segmentation problem by assigning each volumetric region to an anatomical structure. This is accomplished by satisfying constraints at the pixel level, slice level, and volumetric level. Each slice is represented by an attributed graph, where nodes correspond to regions and links correspond to the relations between regions. These regions are obtained by grouping pixels based on similarity and proximity. The slice level attributed graphs are then coerced to form a volumetric attributed graph, where volumetric consistency can be verified. The main novelty of our approach is in the use of the volumetric graph to ensure consistency from symbolic representations obtained from individual slices. In this fashion, the system allows errors to be made at the slice level, yet removes them when the volumetric consistency cannot be verified. Once the segmentation is complete, the 3D surfaces of the brain can be constructed and visualized.

  8. Soft bilateral filtering volumetric shadows using cube shadow maps

    Science.gov (United States)

    Ali, Hatam H.; Sunar, Mohd Shahrizal; Kolivand, Hoshang

    2017-01-01

    Volumetric shadows often increase the realism of rendered scenes in computer graphics. Typical volumetric shadows techniques do not provide a smooth transition effect in real-time with conservation on crispness of boundaries. This research presents a new technique for generating high quality volumetric shadows by sampling and interpolation. Contrary to conventional ray marching method, which requires extensive time, this proposed technique adopts downsampling in calculating ray marching. Furthermore, light scattering is computed in High Dynamic Range buffer to generate tone mapping. The bilateral interpolation is used along a view rays to smooth transition of volumetric shadows with respect to preserving-edges. In addition, this technique applied a cube shadow map to create multiple shadows. The contribution of this technique isreducing the number of sample points in evaluating light scattering and then introducing bilateral interpolation to improve volumetric shadows. This contribution is done by removing the inherent deficiencies significantly in shadow maps. This technique allows obtaining soft marvelous volumetric shadows, having a good performance and high quality, which show its potential for interactive applications. PMID:28632740

  9. 25 CFR 700.59 - Displaced person.

    Science.gov (United States)

    2010-04-01

    ... 25 Indians 2 2010-04-01 2010-04-01 false Displaced person. 700.59 Section 700.59 Indians THE OFFICE OF NAVAJO AND HOPI INDIAN RELOCATION COMMISSION OPERATIONS AND RELOCATION PROCEDURES General Policies and Instructions Definitions § 700.59 Displaced person. Displaced person means a member of...

  10. Volumetric measurement of rock movement using photogrammetry

    Institute of Scientific and Technical Information of China (English)

    Benton Donovan J.; Iverson Stephen R.; Martin Lewis A.; Johnson Jeffrey C.; Raffaldi Michael J

    2016-01-01

    NIOSH ground control safety research program at Spokane, Washington, is exploring applications of pho-togrammetry to rock mass and support monitoring. This paper describes two ways photogrammetric techniques are being used. First, photogrammetric data of laboratory testing is being used to correlate energy input and support deformation. This information can be used to infer remaining support toughness after ground deformation events. This technique is also demonstrated in a field application. Second, field photogrammetric data is compared to crackmeter data from a deep underground mine. Accuracies were found to average 8 mm, but have produced results within 0.2 mm of true displacement, as measured by crackmeters. Application of these techniques consists of monitoring overall fault activity by monitoring multiple points around the crackmeter. A case study is provided in which a crackmeter is clearly shown to have provided insufficient information regarding overall fault ground deformation. Photogrammetry is proving to be a useful ground monitoring tool due to its unobtrusiveness and ease of use.

  11. Displacement and dissipation under the rotating tidal potential, in contrast to Love's geostationary potential

    Science.gov (United States)

    Bostrom, R. C.

    The Earth rotates relative to the solunar gravity field. In consequence the M2, S2 tides are represented by permanent bulges, travelling westward around the Earth as distortion waves. The associated tidal stress ellipsoid progresses perpetually by rotation, without reversal. It is shown that under imperfect elasticity, in lieu of the body forces induced by Love's geostationary time-variant potential a rotating potential induces internal body couples, equally pervasive. Displacement is cumulative, and in the vortical mode formulated by Helmholtz (1858). Whereas in the geostationary formulation of Love cumulative distortion is nil, in actuality this motion is primary, and dimensionally capable of coupling with extant mantle convection. Unlike the marine tides, the bodily wave-tides proceed unhindered around the Earth unhindered by continental margins. Corrected for oceanic effects the complex Love numbers measure dissipation, as commonly supposed. However dissipation is the result of unmapped cumulative vortical displacement (a circulation component), rather than oscillatory forces having the form of a geographically stationary spheroidal eigenvibration. The characteristic period of the loss factor 1/Q is infinity rather than the period pertinent to seismicity or wobble, to which it is dimensionally unrelated. Although primary vorticity-induction is required by the existence of the rotating tidal potential, its tectonic consequences are a matter of speculation, treated elsewhere [1]. --- [1] Bostrom, R.C., 1998. Tectonic Consequences of the Earth's Rotation. Oxfo rd University Press.

  12. Improved volumetric imaging in tomosynthesis using combined multiaxial sweeps.

    Science.gov (United States)

    Gersh, Jacob A; Wiant, David B; Best, Ryan C M; Bennett, Marcus C; Munley, Michael T; King, June D; McKee, Mahta M; Baydush, Alan H

    2010-09-03

    This study explores the volumetric reconstruction fidelity attainable using tomosynthesis with a kV imaging system which has a unique ability to rotate isocentrically and with multiple degrees of mechanical freedom. More specifically, we seek to investigate volumetric reconstructions by combining multiple limited-angle rotational image acquisition sweeps. By comparing these reconstructed images with those of a CBCT reconstruction, we can gauge the volumetric fidelity of the reconstructions. In surgical situations, the described tomosynthesis-based system could provide high-quality volumetric imaging without requiring patient motion, even with rotational limitations present. Projections were acquired using the Digital Integrated Brachytherapy Unit, or IBU-D. A phantom was used which contained several spherical objects of varying contrast. Using image projections acquired during isocentric sweeps around the phantom, reconstructions were performed by filtered backprojection. For each image acquisition sweep configuration, a contrasting sphere is analyzed using two metrics and compared to a gold standard CBCT reconstruction. Since the intersection of a reconstructed sphere and an imaging plane is ideally a circle with an eccentricity of zero, the first metric presented compares the effective eccentricity of intersections of reconstructed volumes and imaging planes. As another metric of volumetric reconstruction fidelity, the volume of one of the contrasting spheres was determined using manual contouring. By comparing these manually delineated volumes with a CBCT reconstruction, we can gauge the volumetric fidelity of reconstructions. The configuration which yielded the highest overall volumetric reconstruction fidelity, as determined by effective eccentricities and volumetric contouring, consisted of two orthogonally-offset 60° L-arm sweeps and a single C-arm sweep which shared a pivot point with one the L-arm sweeps. When compared to a similar configuration that

  13. Aspects of volumetric efficiency measurement for reciprocating engines

    Directory of Open Access Journals (Sweden)

    Pešić Radivoje B.

    2013-01-01

    Full Text Available The volumetric efficiency significantly influences engine output. Both design and dimensions of an intake and exhaust system have large impact on volumetric efficiency. Experimental equipment for measuring of airflow through the engine, which is placed in the intake system, may affect the results of measurements and distort the real picture of the impact of individual structural factors. This paper deals with the problems of experimental determination of intake airflow using orifice plates and the influence of orifice plate diameter on the results of the measurements. The problems of airflow measurements through a multi-process Otto/Diesel engine were analyzed. An original method for determining volumetric efficiency was developed based on in-cylinder pressure measurement during motored operation, and appropriate calibration of the experimental procedure was performed. Good correlation between the results of application of the original method for determination of volumetric efficiency and the results of theoretical model used in research of influence of the intake pipe length on volumetric efficiency was determined. [Acknowledgments. The paper is the result of the research within the project TR 35041 financed by the Ministry of Science and Technological Development of the Republic of Serbia

  14. Displacement of squeezed propagating microwave states

    Science.gov (United States)

    Fedorov, Kirill G.; Zhong, Ling; Pogorzalek, Stefan; Eder, Peter; Fischer, Michael; Goetz, Jan; Wulschner, Friedrich; Xie, Edwar; Menzel, Edwin; Deppe, Frank; Marx, Achim; Gross, Rudolf

    Displacement of propagating squeezed states is a fundamental operation for quantum communications. It can be applied to fundamental studies of macroscopic quantum coherence and has an important role in quantum teleportation protocols with propagating microwaves. We generate propagating squeezed states using a Josephson parametric amplifier and implement displacement using a cryogenic directional coupler. We study single- and two-mode displacement regimes. For the single-mode displacement we find that the squeezing level of the displaced squeezed state does not depend on the displacement amplitude. Also, we observe that quantum entanglement between two spatially separated channels stays constant across 4 orders of displacement power. We acknowledge support by the German Research Foundation through SFB 631 and FE 1564/1-1, the EU project PROMISCE, and Elite Network of Bavaria through the program ExQM.

  15. Resonant neutron-induced atomic displacements

    Science.gov (United States)

    Elmaghraby, Elsayed K.

    2017-05-01

    A model for displacement cascade function was modified to account for the continuous variation of displacement density in the material in response to neutron exposure. The model is based on the Gaussian distribution of displacement energies of atoms in a material. Analytical treatment for moderated epithermal neutron field was given in which the displacement density was divided into two terms, discrete-resonance term and continuum term. Calculation are done for all isotopes using ENDF/B VII.1 data files and temperature dependent cross section library. Weighted elemental values were reported a fitting was performed to obtain energy-dependent formula of displacement density and reduce the number of parameters. Results relevant the present specification of the cascade function are tabulated for each element to enable calculation of displacement density at any value of displacement energy in the between 5 eV and 55 eV.

  16. A Theoretical Model to Predict Both Horizontal Displacement and Vertical Displacement for Electromagnetic Induction-Based Deep Displacement Sensors

    Directory of Open Access Journals (Sweden)

    Xiong Li

    2011-12-01

    Full Text Available Deep displacement observation is one basic means of landslide dynamic study and early warning monitoring and a key part of engineering geological investigation. In our previous work, we proposed a novel electromagnetic induction-based deep displacement sensor (I-type to predict deep horizontal displacement and a theoretical model called equation-based equivalent loop approach (EELA to describe its sensing characters. However in many landslide and related geological engineering cases, both horizontal displacement and vertical displacement vary apparently and dynamically so both may require monitoring. In this study, a II-type deep displacement sensor is designed by revising our I-type sensor to simultaneously monitor the deep horizontal displacement and vertical displacement variations at different depths within a sliding mass. Meanwhile, a new theoretical modeling called the numerical integration-based equivalent loop approach (NIELA has been proposed to quantitatively depict II-type sensors’ mutual inductance properties with respect to predicted horizontal displacements and vertical displacements. After detailed examinations and comparative studies between measured mutual inductance voltage, NIELA-based mutual inductance and EELA-based mutual inductance, NIELA has verified to be an effective and quite accurate analytic model for characterization of II-type sensors. The NIELA model is widely applicable for II-type sensors’ monitoring on all kinds of landslides and other related geohazards with satisfactory estimation accuracy and calculation efficiency.

  17. A theoretical model to predict both horizontal displacement and vertical displacement for electromagnetic induction-based deep displacement sensors.

    Science.gov (United States)

    Shentu, Nanying; Zhang, Hongjian; Li, Qing; Zhou, Hongliang; Tong, Renyuan; Li, Xiong

    2012-01-01

    Deep displacement observation is one basic means of landslide dynamic study and early warning monitoring and a key part of engineering geological investigation. In our previous work, we proposed a novel electromagnetic induction-based deep displacement sensor (I-type) to predict deep horizontal displacement and a theoretical model called equation-based equivalent loop approach (EELA) to describe its sensing characters. However in many landslide and related geological engineering cases, both horizontal displacement and vertical displacement vary apparently and dynamically so both may require monitoring. In this study, a II-type deep displacement sensor is designed by revising our I-type sensor to simultaneously monitor the deep horizontal displacement and vertical displacement variations at different depths within a sliding mass. Meanwhile, a new theoretical modeling called the numerical integration-based equivalent loop approach (NIELA) has been proposed to quantitatively depict II-type sensors' mutual inductance properties with respect to predicted horizontal displacements and vertical displacements. After detailed examinations and comparative studies between measured mutual inductance voltage, NIELA-based mutual inductance and EELA-based mutual inductance, NIELA has verified to be an effective and quite accurate analytic model for characterization of II-type sensors. The NIELA model is widely applicable for II-type sensors' monitoring on all kinds of landslides and other related geohazards with satisfactory estimation accuracy and calculation efficiency.

  18. A high volume, high throughput volumetric sorption analyzer

    Science.gov (United States)

    Soo, Y. C.; Beckner, M.; Romanos, J.; Wexler, C.; Pfeifer, P.; Buckley, P.; Clement, J.

    2011-03-01

    In this talk we will present an overview of our new Hydrogen Test Fixture (HTF) constructed by the Midwest Research Institute for The Alliance for Collaborative Research in Alternative Fuel Technology to test activated carbon monoliths for hydrogen gas storage. The HTF is an automated, computer-controlled volumetric instrument for rapid screening and manipulation of monoliths under an inert atmosphere (to exclude degradation of carbon from exposure to oxygen). The HTF allows us to measure large quantity (up to 500 g) of sample in a 0.5 l test tank, making our results less sensitive to sample inhomogeneity. The HTF can measure isotherms at pressures ranging from 1 to 300 bar at room temperature. For comparison, other volumetric instruments such as Hiden Isochema's HTP-1 Volumetric Analyser can only measure carbon samples up to 150 mg at pressures up to 200 bar. Work supported by the US DOD Contract # N00164-08-C-GS37.

  19. Volumetric (3D) compressive sensing spectral domain optical coherence tomography.

    Science.gov (United States)

    Xu, Daguang; Huang, Yong; Kang, Jin U

    2014-11-01

    In this work, we proposed a novel three-dimensional compressive sensing (CS) approach for spectral domain optical coherence tomography (SD OCT) volumetric image acquisition and reconstruction. Instead of taking a spectral volume whose size is the same as that of the volumetric image, our method uses a sub set of the original spectral volume that is under-sampled in all three dimensions, which reduces the amount of spectral measurements to less than 20% of that required by the Shan-non/Nyquist theory. The 3D image is recovered from the under-sampled spectral data dimension-by-dimension using the proposed three-step CS reconstruction strategy. Experimental results show that our method can significantly reduce the sampling rate required for a volumetric SD OCT image while preserving the image quality.

  20. Multiple sparse volumetric priors for distributed EEG source reconstruction.

    Science.gov (United States)

    Strobbe, Gregor; van Mierlo, Pieter; De Vos, Maarten; Mijović, Bogdan; Hallez, Hans; Van Huffel, Sabine; López, José David; Vandenberghe, Stefaan

    2014-10-15

    We revisit the multiple sparse priors (MSP) algorithm implemented in the statistical parametric mapping software (SPM) for distributed EEG source reconstruction (Friston et al., 2008). In the present implementation, multiple cortical patches are introduced as source priors based on a dipole source space restricted to a cortical surface mesh. In this note, we present a technique to construct volumetric cortical regions to introduce as source priors by restricting the dipole source space to a segmented gray matter layer and using a region growing approach. This extension allows to reconstruct brain structures besides the cortical surface and facilitates the use of more realistic volumetric head models including more layers, such as cerebrospinal fluid (CSF), compared to the standard 3-layered scalp-skull-brain head models. We illustrated the technique with ERP data and anatomical MR images in 12 subjects. Based on the segmented gray matter for each of the subjects, cortical regions were created and introduced as source priors for MSP-inversion assuming two types of head models. The standard 3-layered scalp-skull-brain head models and extended 4-layered head models including CSF. We compared these models with the current implementation by assessing the free energy corresponding with each of the reconstructions using Bayesian model selection for group studies. Strong evidence was found in favor of the volumetric MSP approach compared to the MSP approach based on cortical patches for both types of head models. Overall, the strongest evidence was found in favor of the volumetric MSP reconstructions based on the extended head models including CSF. These results were verified by comparing the reconstructed activity. The use of volumetric cortical regions as source priors is a useful complement to the present implementation as it allows to introduce more complex head models and volumetric source priors in future studies.

  1. Volumetric measurements of a spatially growing dust acoustic wave

    Science.gov (United States)

    Williams, Jeremiah D.

    2012-11-01

    In this study, tomographic particle image velocimetry (tomo-PIV) techniques are used to make volumetric measurements of the dust acoustic wave (DAW) in a weakly coupled dusty plasma system in an argon, dc glow discharge plasma. These tomo-PIV measurements provide the first instantaneous volumetric measurement of a naturally occurring propagating DAW. These measurements reveal over the measured volume that the measured wave mode propagates in all three spatial dimensional and exhibits the same spatial growth rate and wavelength in each spatial direction.

  2. Volumetric measurements of a spatially growing dust acoustic wave

    Energy Technology Data Exchange (ETDEWEB)

    Williams, Jeremiah D. [Physics Department, Wittenberg University, Springfield, Ohio 45504 (United States)

    2012-11-15

    In this study, tomographic particle image velocimetry (tomo-PIV) techniques are used to make volumetric measurements of the dust acoustic wave (DAW) in a weakly coupled dusty plasma system in an argon, dc glow discharge plasma. These tomo-PIV measurements provide the first instantaneous volumetric measurement of a naturally occurring propagating DAW. These measurements reveal over the measured volume that the measured wave mode propagates in all three spatial dimensional and exhibits the same spatial growth rate and wavelength in each spatial direction.

  3. Volumetric Pricing of Agricultural Water Supplies: A Case Study

    Science.gov (United States)

    Griffin, Ronald C.; Perry, Gregory M.

    1985-07-01

    Models of water consumption by rice producers are conceptualized and then estimated using cross-sectional time series data obtained from 16 Texas canal operators for the years 1977-1982. Two alternative econometric models demonstrate that both volumetric and flat rate water charges are strongly and inversely related to agricultural water consumption. Nonprice conservation incentives accompanying flat rates are hypothesized to explain the negative correlation of flat rate charges and water consumption. Application of these results suggests that water supply organizations in the sample population converting to volumetric pricing will generally reduce water consumption.

  4. Displaceable Gear Torque Controlled Driver

    Science.gov (United States)

    Cook, Joseph S., Jr. (Inventor)

    1997-01-01

    Methods and apparatus are provided for a torque driver including a displaceable gear to limit torque transfer to a fastener at a precisely controlled torque limit. A biasing assembly biases a first gear into engagement with a second gear for torque transfer between the first and second gear. The biasing assembly includes a pressurized cylinder controlled at a constant pressure that corresponds to a torque limit. A calibrated gage and valve is used to set the desired torque limit. One or more coiled output linkages connect the first gear with the fastener adaptor which may be a socket for a nut. A gear tooth profile provides a separation force that overcomes the bias to limit torque at the desired torque limit. Multiple fasteners may be rotated simultaneously to a desired torque limit if additional output spur gears are provided. The torque limit is adjustable and may be different for fasteners within the same fastener configuration.

  5. DISPLACEMENT BASED SEISMIC DESIGN CRITERIA

    Energy Technology Data Exchange (ETDEWEB)

    HOFMAYER,C.H.

    1999-03-29

    The USNRC has initiated a project to determine if any of the likely revisions to traditional earthquake engineering practice are relevant to seismic design of the specialized structures, systems and components of nuclear power plants and of such significance to suggest that a change in design practice might be warranted. As part of the initial phase of this study, a literature survey was conducted on the recent changes in seismic design codes/standards, on-going activities of code-writing organizations/communities, and published documents on displacement-based design methods. This paper provides a summary of recent changes in building codes and on-going activities for future codes. It also discusses some technical issues for further consideration.

  6. Displacement Based Seismic Design Criteria

    Energy Technology Data Exchange (ETDEWEB)

    Costello, J.F.; Hofmayer, C.; Park, Y.J.

    1999-03-29

    The USNRC has initiated a project to determine if any of the likely revisions to traditional earthquake engineering practice are relevant to seismic design of the specialized structures, systems and components of nuclear power plants and of such significance to suggest that a change in design practice might be warranted. As part of the initial phase of this study, a literature survey was conducted on the recent changes in seismic design codes/standards, on-going activities of code-writing organizations/communities, and published documents on displacement-based design methods. This paper provides a summary of recent changes in building codes and on-going activities for future codes. It also discusses some technical issues for further consideration.

  7. Remote monitoring of volumetric discharge employing bathymetry determined from surface turbulence metrics

    Science.gov (United States)

    Johnson, E. D.; Cowen, E. A.

    2016-03-01

    Current methods employed by the United States Geological Survey (USGS) to measure river discharge are manpower intensive, expensive, and during high flow events require field personnel to work in dangerous conditions. Indirect methods of estimating river discharge, which involve the use of extrapolated rating curves, can result in gross error during high flow conditions due to extrapolation error and/or bathymetric change. Our goal is to develop a remote method of monitoring volumetric discharge that reduces costs at the same or improved accuracy compared with current methods, while minimizing risk to field technicians. We report the results of Large-Scale Particle Image Velocimetry (LSPIV) and Acoustic Doppler Velocimetry (ADV) measurements conducted in a wide-open channel under a range of flow conditions, i.e., channel aspect ratio (B/H = 6.6-31.9), Reynolds number (ReH = 4,950-73,800), and Froude number (Fr = 0.04-0.46). Experiments were carried out for two different channel cross sections (rectangular and asymmetric compound) and two bathymetric roughness conditions (smooth glass and rough gravel bed). The results show that the mean surface velocity normalized by the depth-averaged velocity (the velocity index) decreases with increasing δ*/H, where δ* is the boundary layer displacement thickness and that the integral length scales, L11,1 and L22,1, calculated on the free-surface vary predictably with the local flow depth. Remote determination of local depth-averaged velocity and flow depth over a channel cross section yields an estimate of volumetric discharge.

  8. Preventing re-displacement through genuine reintegration in Burundi

    Directory of Open Access Journals (Sweden)

    Lucy Hovil

    2012-12-01

    Full Text Available Displacement is often part of a cyclical process of conflict anddisplacement. Preventing displacement, therefore, is not only aboutpreventing new displacement but about ensuring that people do notget re-displaced.

  9. Modelling toehold-mediated RNA strand displacement

    CERN Document Server

    Šulc, Petr; Romano, Flavio; Doye, Jonathan P K; Louis, Ard A

    2014-01-01

    We study the thermodynamics and kinetics of an RNA toehold-mediated strand displacement reaction with a recently developed coarse-grained model of RNA. Strand displacement, during which a single strand displaces a different strand previously bound to a complementary substrate strand, is an essential mechanism in active nucleic acid nanotechnology and has also been hypothesized to occur in vivo. We study the rate of displacement reactions as a function of the length of the toehold and temperature and make two experimentally testable predictions: that the displacement is faster if the toehold is placed at the 5' end of the substrate and that the displacement slows down with increasing temperature for longer toeholds.

  10. PENGARUH UKURAN UTAMA KAPAL TERHADAP DISPLACEMENT KAPAL

    Directory of Open Access Journals (Sweden)

    Budi Utomo

    2012-02-01

    Full Text Available Displacement is weight water which is replaced ship hull. The displacement influenced by dimension of inmerchant ship. The displacement musat be small as posible, but the capacity and the speed must be pullfill.Dsplacement can be obtained by formulation or by experiment in hydrodinamika laobatory, the modelingcharacteristic us descube the real Calculation of the ship.The form of the ship must give the resistaise as small as posible. In athe hard the capacity must be full fill ofload

  11. In Vivo Real Time Volumetric Synthetic Aperture Ultrasound Imaging

    DEFF Research Database (Denmark)

    Bouzari, Hamed; Rasmussen, Morten Fischer; Brandt, Andreas Hjelm;

    2015-01-01

    Synthetic aperture (SA) imaging can be used to achieve real-time volumetric ultrasound imaging using 2-D array transducers. The sensitivity of SA imaging is improved by maximizing the acoustic output, but one must consider the limitations of an ultrasound system, both technical and biological...

  12. Automatic segmentation of pulmonary segments from volumetric chest CT scans.

    NARCIS (Netherlands)

    Rikxoort, E.M. van; Hoop, B. de; Vorst, S. van de; Prokop, M.; Ginneken, B. van

    2009-01-01

    Automated extraction of pulmonary anatomy provides a foundation for computerized analysis of computed tomography (CT) scans of the chest. A completely automatic method is presented to segment the lungs, lobes and pulmonary segments from volumetric CT chest scans. The method starts with lung segmenta

  13. Volumetric T-spline Construction Using Boolean Operations

    Science.gov (United States)

    2013-07-01

    15213, USA 2 Institute for Computational Engineering and Sciences, The University of Texas at Austin, Austin, TX 78712, USA 3 Department of Civil and...and S. Yau. Volumetric harmonic map. Communications in Information and Systems, 3(3):191–202, 2003. 12. C.A.R. Guerra . Simultaneous untangling and

  14. Volumetric motion quantification by 3D tissue phase mapped CMR

    Directory of Open Access Journals (Sweden)

    Lutz Anja

    2012-10-01

    Full Text Available Abstract Background The objective of this study was the quantification of myocardial motion from 3D tissue phase mapped (TPM CMR. Recent work on myocardial motion quantification by TPM has been focussed on multi-slice 2D acquisitions thus excluding motion information from large regions of the left ventricle. Volumetric motion assessment appears an important next step towards the understanding of the volumetric myocardial motion and hence may further improve diagnosis and treatments in patients with myocardial motion abnormalities. Methods Volumetric motion quantification of the complete left ventricle was performed in 12 healthy volunteers and two patients applying a black-blood 3D TPM sequence. The resulting motion field was analysed regarding motion pattern differences between apical and basal locations as well as for asynchronous motion pattern between different myocardial segments in one or more slices. Motion quantification included velocity, torsion, rotation angle and strain derived parameters. Results All investigated motion quantification parameters could be calculated from the 3D-TPM data. Parameters quantifying hypokinetic or asynchronous motion demonstrated differences between motion impaired and healthy myocardium. Conclusions 3D-TPM enables the gapless volumetric quantification of motion abnormalities of the left ventricle, which can be applied in future application as additional information to provide a more detailed analysis of the left ventricular function.

  15. Video-rate volumetric optical coherence tomography-based microangiography

    Science.gov (United States)

    Baran, Utku; Wei, Wei; Xu, Jingjiang; Qi, Xiaoli; Davis, Wyatt O.; Wang, Ruikang K.

    2016-04-01

    Video-rate volumetric optical coherence tomography (vOCT) is relatively young in the field of OCT imaging but has great potential in biomedical applications. Due to the recent development of the MHz range swept laser sources, vOCT has started to gain attention in the community. Here, we report the first in vivo video-rate volumetric OCT-based microangiography (vOMAG) system by integrating an 18-kHz resonant microelectromechanical system (MEMS) mirror with a 1.6-MHz FDML swept source operating at ˜1.3 μm wavelength. Because the MEMS scanner can offer an effective B-frame rate of 36 kHz, we are able to engineer vOMAG with a video rate up to 25 Hz. This system was utilized for real-time volumetric in vivo visualization of cerebral microvasculature in mice. Moreover, we monitored the blood perfusion dynamics during stimulation within mouse ear in vivo. We also discussed this system's limitations. Prospective MEMS-enabled OCT probes with a real-time volumetric functional imaging capability can have a significant impact on endoscopic imaging and image-guided surgery applications.

  16. Effects of hemiplegy on pulmonary function and diaphragmatic dome displacement.

    Science.gov (United States)

    de Almeida, Izabella Cecília Lima; Clementino, Adriana Carla Costa Ribeiro; Rocha, Eduardo Henrique Tenório; Brandão, Daniella Cunha; Dornelas de Andrade, Armele

    2011-09-15

    We evaluated the diaphragmatic excursion, volumetric measurement, maximal inspiratory pressure (PI(max)), lung function tests (forced vital capacity-FVC, forced expiratory volume in the first second-FEV1, mean forced expiratory flow between 25 and 75% of the FVC maneuver-FEF(25-75%), peak expiratory flow-PEF and maximal voluntary ventilation-MVV), displacement of the domes diaphragmatics with ultrasonography and inspiratory capacity, the MAS scale (Motor Assessment Scale) in 20 hemiplegic patients volunteers and eight controls. In right-side hemiplegia, movement was 4.97 ± 0.78 cm and 4.20 ± 1.45 cm for the right and left domes of the diaphragm, respectively, whereas these values were 4.42 ± 0.92 cm and 4.66 ± 1.17 cm in left-side hemiplegia. PI(max) was -48.75 ± 27.5 cmH2O in right-side hemiplegic patients and -74.17 ± 13.57 cmH2O in left-side hemiplegic patients. Right-side hemiplegia exhibited greater impairment of the respiratory muscles than left-side hemiplegia due to the physiologic positioning of the domes of the diaphragm which may be compromised for hemiplegia.

  17. Displacement of Propagating Squeezed Microwave States

    Science.gov (United States)

    Fedorov, Kirill G.; Zhong, L.; Pogorzalek, S.; Eder, P.; Fischer, M.; Goetz, J.; Xie, E.; Wulschner, F.; Inomata, K.; Yamamoto, T.; Nakamura, Y.; Di Candia, R.; Las Heras, U.; Sanz, M.; Solano, E.; Menzel, E. P.; Deppe, F.; Marx, A.; Gross, R.

    2016-07-01

    Displacement of propagating quantum states of light is a fundamental operation for quantum communication. It enables fundamental studies on macroscopic quantum coherence and plays an important role in quantum teleportation protocols with continuous variables. In our experiments, we have successfully implemented this operation for propagating squeezed microwave states. We demonstrate that, even for strong displacement amplitudes, there is no degradation of the squeezing level in the reconstructed quantum states. Furthermore, we confirm that path entanglement generated by using displaced squeezed states remains constant over a wide range of the displacement power.

  18. Tracking speckle displacement by double Kalman filtering

    Institute of Scientific and Technical Information of China (English)

    Donghui Li; Li Guo

    2006-01-01

    @@ A tracking technique using two sequentially-connected Kalman filter for tracking laser speckle displacement is presented. One Kalman filter tracks temporal speckle displacement, while another Kalman filter tracks spatial speckle displacement. The temporal Kalman filter provides a prior for the spatial Kalman filter, and the spatial Kalman filter provides measurements for the temporal Kalman filter. The contribution of a prior to estimations of the spatial Kalman filter is analyzed. An optical analysis system was set up to verify the double-Kalman-filter tracker's ability of tracking laser speckle's constant displacement.

  19. Displacement based multilevel structural optimization

    Science.gov (United States)

    Striz, Alfred G.

    1995-01-01

    Multidisciplinary design optimization (MDO) is expected to play a major role in the competitive transportation industries of tomorrow, i.e., in the design of aircraft and spacecraft, of high speed trains, boats, and automobiles. All of these vehicles require maximum performance at minimum weight to keep fuel consumption low and conserve resources. Here, MDO can deliver mathematically based design tools to create systems with optimum performance subject to the constraints of disciplines such as structures, aerodynamics, controls, etc. Although some applications of MDO are beginning to surface, the key to a widespread use of this technology lies in the improvement of its efficiency. This aspect is investigated here for the MDO subset of structural optimization, i.e., for the weight minimization of a given structure under size, strength, and displacement constraints. Specifically, finite element based multilevel optimization of structures (here, statically indeterminate trusses and beams for proof of concept) is performed. In the system level optimization, the design variables are the coefficients of assumed displacement functions, and the load unbalance resulting from the solution of the stiffness equations is minimized. Constraints are placed on the deflection amplitudes and the weight of the structure. In the subsystems level optimizations, the weight of each element is minimized under the action of stress constraints, with the cross sectional dimensions as design variables. This approach is expected to prove very efficient, especially for complex structures, since the design task is broken down into a large number of small and efficiently handled subtasks, each with only a small number of variables. This partitioning will also allow for the use of parallel computing, first, by sending the system and subsystems level computations to two different processors, ultimately, by performing all subsystems level optimizations in a massively parallel manner on separate

  20. Analysis of Changing Swarm Rate using Volumetric Strain

    Science.gov (United States)

    Kumazawa, T.; Ogata, Y.; Kimura, K.; Maeda, K.; Kobayashi, A.

    2015-12-01

    Near the eastern coast of Izu peninsula is an active submarine volcanic region in Japan, where magma intrusions have been observed many times. The forecast of earthquake swarm activities and eruptions are serious concern particularly in nearby hot spring resort areas. It is well known that temporal durations of the swarm activities have been correlated with early volumetric strain changes at a certain observation station of about 20 km distance apart. Therefore the Earthquake Research Committee (2010) investigated some empirical statistical relations to predict sizes of the swarm activity. Here we looked at the background seismicity rate changes during these swarm periods using the non-stationary ETAS model (Kumazawa and Ogata, 2013, 2014), and have found the followings. The modified volumetric strain data, by removing the effect of earth tides, precipitation and coseismic jumps, have significantly higher cross-correlations to the estimated background rates of the ETAS model than to the swarm rate-changes. Specifically, the background seismicity rate synchronizes clearer to the strain change by the lags around a half day. These relations suggest an enhanced prediction of earthquakes in this region using volumetric strain measurements. Hence we propose an extended ETAS model where the background rate is modulated by the volumetric strain data. We have also found that the response function to the strain data can be well approximated by an exponential functions with the same decay rate, but that their intersects are inversely proportional to the distances between the volumetric strain-meter and the onset location of the swarm. Our numerical results by the same proposed model show consistent outcomes for the various major swarms in this region.

  1. Arizona: In Search of the Displaced Homemaker.

    Science.gov (United States)

    Woods, Doris

    The model described offers information about displaced homemakers that, while specific to Arizona, can provide a guide to persons in any state responsible for program planning. The report presents results of an Arizona Department of Education study which was conducted to: (1) identify the "displaced homemaker;" (2) define the need for services;…

  2. Seismic displacement of gravity retaining walls

    Directory of Open Access Journals (Sweden)

    Kamal Mohamed Hafez Ismail Ibrahim

    2015-08-01

    Full Text Available Seismic displacement of gravity walls had been studied using conventional static methods for controlled displacement design. In this study plain strain numerical analysis is performed using Plaxis dynamic program where prescribed displacement is applied at the bottom boundary of the soil to simulate the applied seismic load. Constrained absorbent side boundaries are introduced to prevent any wave reflection. The studied soil is chosen dense granular sand and modeled as elasto-plastic material according to Mohr–Column criteria while the gravity wall is assumed elastic. By comparing the resulted seismic wall displacements calculated by numerical analysis for six historical ground motions with that calculated by the pseudo-static method, it is found that numerical seismic displacements are either equal to or greater than corresponding pseudo-static values. Permissible seismic wall displacement calculated by AASHTO can be used for empirical estimation of seismic displacement. It is also found that seismic wall displacement is directly proportional with the positive angle of inclination of the back surface of the wall, soil flexibility and with the earthquake maximum ground acceleration. Seismic wall sliding is dominant and rotation is negligible for rigid walls when the ratio between the wall height and the foundation width is less than 1.4, while for greater ratios the wall becomes more flexible and rotation (rocking increases till the ratio reaches 1.8 where overturning is susceptible to take place. Cumulative seismic wall rotation increases with dynamic time and tends to be constant at the end of earthquake.

  3. Flow cell system for miscible displacement experiments

    Energy Technology Data Exchange (ETDEWEB)

    Yoo, S.H.; Kirkham, D.

    1971-02-01

    The use of a continuous graphic recording system for flow-component measurement in miscible displacement experiments is described. This system measures and continuously records radioactive tracer concentrations of effluents of miscible displacement columns. The recordings are needed breakthrough curves. The use of the system obviates fraction collectors.

  4. Etiopathogenesis of abomasal displacement in cattle

    Directory of Open Access Journals (Sweden)

    Šamanc Horea

    2003-01-01

    Full Text Available Abomasal displacement presents topographic gastropathy, where this organ has changed its position, and there is simultaneous dilatation which can vary in intensity. The incidence of this disorder in herds of high-yield dairy cows varies to a great degree (1 to 18 %. Abomasal displacement was established in herds of East-Frisian cows in 1 to 3% animals, and in Holstein cow herds in 5 to 18 % animals. The most frequent abomasal displacement is to the left (88%. There is significant seasonal variation in the incidence of abomasal displacement. About two-thirds of cases of abomasal displacement are diagnosed from October until April. The disorder appears more frequently in cows with repeated lactations. It has been established that it appears after the first calving in 27.8% cases, after the second to fifth calving in 66.7% cases, and after the sixth and seventh calving in 5.5% of the cows. The response of endocrine pancreas B-cells for insulin secretion to hyperglycaemia caused by applying an excess-glucose test is reduced in cows with left abomasal displacement, and there is constant hyperglycaemia in cows with right abomasal displacement. The excess-glucose test indicates a disrupted function of the endocrine pancreas in diseased animals. It has been determined through examinations of Aml genotypes in Holstein cow herds in connection with the appearance of abomasal displacement, that the occurrence of this disorder cannot be attributed to a genetic predisposition.

  5. Internal displacement in Colombia: Fifteen distinguishing features.

    Science.gov (United States)

    Shultz, James M; Ceballos, Ángela Milena Gómez; Espinel, Zelde; Oliveros, Sofia Rios; Fonseca, Maria Fernanda; Florez, Luis Jorge Hernandez

    2014-01-01

    This commentary aims to delineate the distinguishing features of conflict-induced internal displacement in the nation of Colombia, South America. Even as Colombia is currently implementing a spectrum of legal, social, economic, and health programs for "victims of armed conflict," with particular focus on internally displaced persons (IDPs), the dynamics of forced migration on a mass scale within this country are little known beyond national borders.   The authors of this commentary are embarking on a global mental health research program in Bogota, Colombia to define best practices for reaching the displaced population and implementing sustainable, evidence-based screening and intervention for common mental disorders. Presenting the defining characteristics of internal displacement in Colombia provides the context for our work and, more importantly, conveys the compelling and complex nature of this humanitarian crisis. We attempt to demonstrate Colombia's unique position within the global patterning of internal displacement.

  6. Nonsurgical gingival displacement in restorative dentistry.

    Science.gov (United States)

    Thomas, Manuel S; Joseph, Robin Mathai; Parolia, Abhishek

    2011-06-01

    Gingival displacement is critical for obtaining accurate impressions for the fabrication of fixed restorations, especially when the finish line is at or just within the gingival sulcus. Displacement of the gingival tissue is also important when dealing with the restoration of cervical lesions due to their proximity to the periodontal tissue. The methods of gingival tissue displacement can be broadly classified as nonsurgical and surgical techniques, with nonsurgical being the more commonly practiced method. Dentists must alter their armamentarium and gingival displacement techniques to meet specific demands and obtain predictable results. Hence, the purpose of this article is to describe the different means by which nonsurgical gingival displacement can be achieved effectively under a variety of clinical situations.

  7. Enhanced oil recovery by surfactant-enhanced volumetric sweep efficiency: Second annual report, September 30, 1986-September 30, 1987

    Energy Technology Data Exchange (ETDEWEB)

    Harwell, J H; Scamehorn, J F

    1988-04-01

    It is widely known that heterogeneities in oil reservoirs occurring as a result of permeability variations in the rock can have a detrimental effect on an oil recovery process; preferential diversion of injected displacement fluid occurs through the high-permeability zones, leaving the lower-permeability zones at a high residual oil content at a time when it is no longer economically viable to continue the oil recovery process. A novel oil recovery process is described which aims to improve the volumetric sweep efficiency of oil recovery. High-permeability zones are partially or completely plugged off by using the chromatographic and phase behavior of surfactants and their mixtures and the preferential invasion of high-permeability areas by low-viscosity injected fluids. The plugging will divert flow into regions of higher oil saturation. 85 refs., 46 figs., 6 tabs.

  8. An initial study on the estimation of time-varying volumetric treatment images and 3D tumor localization from single MV cine EPID images.

    Science.gov (United States)

    Mishra, Pankaj; Li, Ruijiang; Mak, Raymond H; Rottmann, Joerg; Bryant, Jonathan H; Williams, Christopher L; Berbeco, Ross I; Lewis, John H

    2014-08-01

    In this work the authors develop and investigate the feasibility of a method to estimate time-varying volumetric images from individual MV cine electronic portal image device (EPID) images. The authors adopt a two-step approach to time-varying volumetric image estimation from a single cine EPID image. In the first step, a patient-specific motion model is constructed from 4DCT. In the second step, parameters in the motion model are tuned according to the information in the EPID image. The patient-specific motion model is based on a compact representation of lung motion represented in displacement vector fields (DVFs). DVFs are calculated through deformable image registration (DIR) of a reference 4DCT phase image (typically peak-exhale) to a set of 4DCT images corresponding to different phases of a breathing cycle. The salient characteristics in the DVFs are captured in a compact representation through principal component analysis (PCA). PCA decouples the spatial and temporal components of the DVFs. Spatial information is represented in eigenvectors and the temporal information is represented by eigen-coefficients. To generate a new volumetric image, the eigen-coefficients are updated via cost function optimization based on digitally reconstructed radiographs and projection images. The updated eigen-coefficients are then multiplied with the eigenvectors to obtain updated DVFs that, in turn, give the volumetric image corresponding to the cine EPID image. The algorithm was tested on (1) Eight digital eXtended CArdiac-Torso phantom datasets based on different irregular patient breathing patterns and (2) patient cine EPID images acquired during SBRT treatments. The root-mean-squared tumor localization error is (0.73 ± 0.63 mm) for the XCAT data and (0.90 ± 0.65 mm) for the patient data. The authors introduced a novel method of estimating volumetric time-varying images from single cine EPID images and a PCA-based lung motion model. This is the first method to estimate

  9. An initial study on the estimation of time-varying volumetric treatment images and 3D tumor localization from single MV cine EPID images

    Energy Technology Data Exchange (ETDEWEB)

    Mishra, Pankaj, E-mail: pankaj.mishra@varian.com; Mak, Raymond H.; Rottmann, Joerg; Bryant, Jonathan H.; Williams, Christopher L.; Berbeco, Ross I.; Lewis, John H. [Brigham and Women' s Hospital, Dana-Farber Cancer Institute and Harvard Medical School, Boston, Massachusetts 02115 (United States); Li, Ruijiang [Department of Radiation Oncology, Stanford University School of Medicine, Stanford, California 94305 (United States)

    2014-08-15

    Purpose: In this work the authors develop and investigate the feasibility of a method to estimate time-varying volumetric images from individual MV cine electronic portal image device (EPID) images. Methods: The authors adopt a two-step approach to time-varying volumetric image estimation from a single cine EPID image. In the first step, a patient-specific motion model is constructed from 4DCT. In the second step, parameters in the motion model are tuned according to the information in the EPID image. The patient-specific motion model is based on a compact representation of lung motion represented in displacement vector fields (DVFs). DVFs are calculated through deformable image registration (DIR) of a reference 4DCT phase image (typically peak-exhale) to a set of 4DCT images corresponding to different phases of a breathing cycle. The salient characteristics in the DVFs are captured in a compact representation through principal component analysis (PCA). PCA decouples the spatial and temporal components of the DVFs. Spatial information is represented in eigenvectors and the temporal information is represented by eigen-coefficients. To generate a new volumetric image, the eigen-coefficients are updated via cost function optimization based on digitally reconstructed radiographs and projection images. The updated eigen-coefficients are then multiplied with the eigenvectors to obtain updated DVFs that, in turn, give the volumetric image corresponding to the cine EPID image. Results: The algorithm was tested on (1) Eight digital eXtended CArdiac-Torso phantom datasets based on different irregular patient breathing patterns and (2) patient cine EPID images acquired during SBRT treatments. The root-mean-squared tumor localization error is (0.73 ± 0.63 mm) for the XCAT data and (0.90 ± 0.65 mm) for the patient data. Conclusions: The authors introduced a novel method of estimating volumetric time-varying images from single cine EPID images and a PCA-based lung motion model

  10. Virtual Sectioning and Haptic Exploration of Volumetric Shapes in the Absence of Visual Feedback

    Directory of Open Access Journals (Sweden)

    Tatiana V. Evreinova

    2013-01-01

    Full Text Available The reduced behavior for exploration of volumetric data based on the virtual sectioning concept was compared with the free scanning at the use of the StickGrip linkage-free haptic device. Profiles of the virtual surface were simulated through the penholder displacements in relation to the pen tip of the stylus. One or two geometric shapes (cylinder, trapezoidal prism, ball, and torus or their halves and the ripple surface were explored in the absence of visual feedback. In the free scanning, the person physically moved the stylus. In the parallel scanning, cross-sectional profiles were generated automatically starting from the location indicated by the stylus. Analysis of the performance of 18 subjects demonstrated that the new haptic visualization and exploration technique allowed to create accurate mental images, to recognize and identify virtual shapes. The mean number of errors was about 2.5% in the free scanning mode and 1.9% and 1.5% in the parallel scanning mode at the playback velocity of 28 mm/s and 42 mm/s, respectively. All participants agreed that the haptic visualization of the 3D virtual surface presented as the cross-sectional slices of the workspace was robust and easy to use. The method was developed for visualization of spatially distributed data collected by sensors.

  11. Volumetric analysis of the mandibular condyle using cone beam computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Bayram, Mehmet, E-mail: dtmehmetbayram@yahoo.com [Karadeniz Technical University, Faculty of Dentistry, Department of Orthodontics, 61080 Trabzon (Turkey); Kayipmaz, Saadettin; Sezgin, Oemer Said [Karadeniz Technical University, Faculty of Dentistry, Department of Oral Radiology, Trabzon (Turkey); Kuecuek, Murat [Karadeniz Technical University, Faculty of Arts and Sciences, Department of Chemistry, Trabzon (Turkey)

    2012-08-15

    Objective: The aim was to determine the accuracy of volumetric analysis of the mandibular condyle using cone-beam computed tomography (CBCT). Materials and methods: Five dry mandibles containing 9 condyles were used. CBCT scans of the mandibles and an impression of each condylar area were taken. The physical volumes of the condyles were calculated as the gold standard using the water displacement technique. After isolating, the condylar volume was sectioned in the sagittal plane, and 0.3 mm thick sections with 0.9 mm intervals were obtained from 3D reconstructions. Using the Cavalieri principle, the volume of each condyle was estimated from the CBCT images by three observers. The accuracy of the CBCT volume measurements and the relation agreements between the results of the three observers were assessed using the Wilcoxon Signed Rank test and Pearson correlation test. The level of statistical significance was set at 0.05. Results: The results of the Pearson correlation showed that there were highly significant positive correlations between the observers' measurements. According to the results of the Wilcoxon Signed Rank test comparing the physical and observers' measurements, there were no statistically significant differences (p > 0.05). Conclusion: The Cavalieri principle, used in conjunction with a planimetry method, is a valid and effective method for volume estimation of the mandibular condyle on CBCT images.

  12. Comparison between multislice and cone-beam computerized tomography in the volumetric assessment of cleft palate.

    Science.gov (United States)

    Albuquerque, Marco Antonio; Gaia, Bruno Felipe; Cavalcanti, Marcelo Gusmão Paraíso

    2011-08-01

    The aim of this study was to determine the applicability of multislice and cone-beam computerized tomography (CT) in the assessment of bone defects in patients with oral clefts. Bone defects were produced in 9 dry skulls to mimic oral clefts. All defects were modeled with wax. The skulls were submitted to multislice and cone-beam CT. Subsequently, physical measurements were obtained by the Archimedes principle of water displacement of wax models. The results demonstrated that multislice and cone-beam CT showed a high efficiency rate and were considered to be effective for volumetric assessment of bone defects. It was also observed that both CT modalities showed excellent results with high reliability in the study of the volume of bone defects, with no difference in performance between them. The clinical applicability of our research has shown these CT modalities to be immediate and direct, and they is important for the diagnosis and therapeutic process of patients with oral cleft. Copyright © 2011 Mosby, Inc. All rights reserved.

  13. Pulse sequence for dynamic volumetric imaging of hyperpolarized metabolic products

    Science.gov (United States)

    Cunningham, Charles H.; Chen, Albert P.; Lustig, Michael; Hargreaves, Brian A.; Lupo, Janine; Xu, Duan; Kurhanewicz, John; Hurd, Ralph E.; Pauly, John M.; Nelson, Sarah J.; Vigneron, Daniel B.

    2008-07-01

    Dynamic nuclear polarization and dissolution of a 13C-labeled substrate enables the dynamic imaging of cellular metabolism. Spectroscopic information is typically acquired, making the acquisition of dynamic volumetric data a challenge. To enable rapid volumetric imaging, a spectral-spatial excitation pulse was designed to excite a single line of the carbon spectrum. With only a single resonance present in the signal, an echo-planar readout trajectory could be used to resolve spatial information, giving full volume coverage of 32 × 32 × 16 voxels every 3.5 s. This high frame rate was used to measure the different lactate dynamics in different tissues in a normal rat model and a mouse model of prostate cancer.

  14. Nonrigid registration of volumetric images using ranked order statistics

    DEFF Research Database (Denmark)

    Tennakoon, Ruwan; Bab-Hadiashar, Alireza; Cao, Zhenwei

    2014-01-01

    Non-rigid image registration techniques using intensity based similarity measures are widely used in medical imaging applications. Due to high computational complexities of these techniques, particularly for volumetric images, finding appropriate registration methods to both reduce the computation...... burden and increase the registration accuracy has become an intensive area of research. In this paper we propose a fast and accurate non-rigid registration method for intra-modality volumetric images. Our approach exploits the information provided by an order statistics based segmentation method, to find...... the important regions for registration and use an appropriate sampling scheme to target those areas and reduce the registration computation time. A unique advantage of the proposed method is its ability to identify the point of diminishing returns and stop the registration process. Our experiments...

  15. Volumetric characterization of delamination fields via angle longitudinal wave ultrasound

    Science.gov (United States)

    Wertz, John; Wallentine, Sarah; Welter, John; Dierken, Josiah; Aldrin, John

    2017-02-01

    The volumetric characterization of delaminations necessarily precedes rigorous composite damage progression modeling. Yet, inspection of composite structures for subsurface damage remains largely focused on detection, resulting in a capability gap. In response to this need, angle longitudinal wave ultrasound was employed to characterize a composite surrogate containing a simulated three-dimensional delamination field with distinct regions of occluded features (shadow regions). Simple analytical models of the specimen were developed to guide subsequent experimentation through identification of optimal scanning parameters. The ensuing experiments provided visual evidence of the complete delamination field, including indications of features within the shadow regions. The results of this study demonstrate proof-of-principle for the use of angle longitudinal wave ultrasonic inspection for volumetric characterization of three-dimensional delamination fields. Furthermore, the techniques developed herein form the foundation of succeeding efforts to characterize impact delaminations within inhomogeneous laminar materials such as polymer matrix composites.

  16. Magnetic Resonance Image Segmentation and its Volumetric Measurement

    Directory of Open Access Journals (Sweden)

    Rahul R. Ambalkar

    2013-02-01

    Full Text Available Image processing techniques make it possible to extract meaningful information from medical images. Magnetic resonance (MR imaging has been widely applied in biological research and diagnostics because of its excellent soft tissue contrast, non-invasive character, high spatial resolution and easy slice selection at any orientation. The MRI-based brain volumetric is concerned with the analysis of volumes and shapes of the structural components of the human brain. It also provides a criterion, by which we recognize the presence of degenerative diseases and characterize their rates of progression to make the diagnosis and treatments as a easy task. In this paper we have proposed an automated method for volumetric measurement of Magnetic Resonance Imaging and used Self Organized Map (SOM clustering method for their segmentations. We have used the MRI data set of 61 slices of 256×256 pixels in DICOM standard format

  17. Two-dimensional random arrays for real time volumetric imaging

    DEFF Research Database (Denmark)

    Davidsen, Richard E.; Jensen, Jørgen Arendt; Smith, Stephen W.

    1994-01-01

    Two-dimensional arrays are necessary for a variety of ultrasonic imaging techniques, including elevation focusing, 2-D phase aberration correction, and real time volumetric imaging. In order to reduce system cost and complexity, sparse 2-D arrays have been considered with element geometries...... real time volumetric imaging system, which employs a wide transmit beam and receive mode parallel processing to increase image frame rate. Depth-of-field comparisons were made from simulated on-axis and off-axis beamplots at ranges from 30 to 160 mm for both coaxial and offset transmit and receive...... selected ad hoc, by algorithm, or by random process. Two random sparse array geometries and a sparse array with a Mills cross receive pattern were simulated and compared to a fully sampled aperture with the same overall dimensions. The sparse arrays were designed to the constraints of the Duke University...

  18. In Vivo Real Time Volumetric Synthetic Aperture Ultrasound Imaging

    DEFF Research Database (Denmark)

    Bouzari, Hamed; Rasmussen, Morten Fischer; Brandt, Andreas Hjelm

    2015-01-01

    . This paper investigates the in vivo applicability and sensitivity of volumetric SA imaging. Utilizing the transmit events to generate a set of virtual point sources, a frame rate of 25 Hz for a 90° x 90° field-of-view was achieved. Data were obtained using a 3.5 MHz 32 x 32 elements 2-D phased array......Synthetic aperture (SA) imaging can be used to achieve real-time volumetric ultrasound imaging using 2-D array transducers. The sensitivity of SA imaging is improved by maximizing the acoustic output, but one must consider the limitations of an ultrasound system, both technical and biological...... transducer connected to the experimental scanner (SARUS). Proper scaling is applied to the excitation signal such that intensity levels are in compliance with the U.S. Food and Drug Administration regulations for in vivo ultrasound imaging. The measured Mechanical Index and spatial-peak- temporal...

  19. COMPARISON OF VOLUMETRIC REGISTRATION ALGORITHMS FOR TENSOR-BASED MORPHOMETRY

    Science.gov (United States)

    Villalon, Julio; Joshi, Anand A.; Toga, Arthur W.; Thompson, Paul M.

    2015-01-01

    Nonlinear registration of brain MRI scans is often used to quantify morphological differences associated with disease or genetic factors. Recently, surface-guided fully 3D volumetric registrations have been developed that combine intensity-guided volume registrations with cortical surface constraints. In this paper, we compare one such algorithm to two popular high-dimensional volumetric registration methods: large-deformation viscous fluid registration, formulated in a Riemannian framework, and the diffeomorphic “Demons” algorithm. We performed an objective morphometric comparison, by using a large MRI dataset from 340 young adult twin subjects to examine 3D patterns of correlations in anatomical volumes. Surface-constrained volume registration gave greater effect sizes for detecting morphometric associations near the cortex, while the other two approaches gave greater effects sizes subcortically. These findings suggest novel ways to combine the advantages of multiple methods in the future. PMID:26925198

  20. Volumetric 3D display using a DLP projection engine

    Science.gov (United States)

    Geng, Jason

    2012-03-01

    In this article, we describe a volumetric 3D display system based on the high speed DLPTM (Digital Light Processing) projection engine. Existing two-dimensional (2D) flat screen displays often lead to ambiguity and confusion in high-dimensional data/graphics presentation due to lack of true depth cues. Even with the help of powerful 3D rendering software, three-dimensional (3D) objects displayed on a 2D flat screen may still fail to provide spatial relationship or depth information correctly and effectively. Essentially, 2D displays have to rely upon capability of human brain to piece together a 3D representation from 2D images. Despite the impressive mental capability of human visual system, its visual perception is not reliable if certain depth cues are missing. In contrast, volumetric 3D display technologies to be discussed in this article are capable of displaying 3D volumetric images in true 3D space. Each "voxel" on a 3D image (analogous to a pixel in 2D image) locates physically at the spatial position where it is supposed to be, and emits light from that position toward omni-directions to form a real 3D image in 3D space. Such a volumetric 3D display provides both physiological depth cues and psychological depth cues to human visual system to truthfully perceive 3D objects. It yields a realistic spatial representation of 3D objects and simplifies our understanding to the complexity of 3D objects and spatial relationship among them.

  1. Volumetric Light-field Encryption at the Microscopic Scale

    Science.gov (United States)

    Li, Haoyu; Guo, Changliang; Muniraj, Inbarasan; Schroeder, Bryce C.; Sheridan, John T.; Jia, Shu

    2017-01-01

    We report a light-field based method that allows the optical encryption of three-dimensional (3D) volumetric information at the microscopic scale in a single 2D light-field image. The system consists of a microlens array and an array of random phase/amplitude masks. The method utilizes a wave optics model to account for the dominant diffraction effect at this new scale, and the system point-spread function (PSF) serves as the key for encryption and decryption. We successfully developed and demonstrated a deconvolution algorithm to retrieve both spatially multiplexed discrete data and continuous volumetric data from 2D light-field images. Showing that the method is practical for data transmission and storage, we obtained a faithful reconstruction of the 3D volumetric information from a digital copy of the encrypted light-field image. The method represents a new level of optical encryption, paving the way for broad industrial and biomedical applications in processing and securing 3D data at the microscopic scale.

  2. Volumetric Light-field Encryption at the Microscopic Scale

    Science.gov (United States)

    Li, Haoyu; Guo, Changliang; Muniraj, Inbarasan; Schroeder, Bryce C.; Sheridan, John T.; Jia, Shu

    2017-01-01

    We report a light-field based method that allows the optical encryption of three-dimensional (3D) volumetric information at the microscopic scale in a single 2D light-field image. The system consists of a microlens array and an array of random phase/amplitude masks. The method utilizes a wave optics model to account for the dominant diffraction effect at this new scale, and the system point-spread function (PSF) serves as the key for encryption and decryption. We successfully developed and demonstrated a deconvolution algorithm to retrieve both spatially multiplexed discrete data and continuous volumetric data from 2D light-field images. Showing that the method is practical for data transmission and storage, we obtained a faithful reconstruction of the 3D volumetric information from a digital copy of the encrypted light-field image. The method represents a new level of optical encryption, paving the way for broad industrial and biomedical applications in processing and securing 3D data at the microscopic scale. PMID:28059149

  3. Volumetric Light-field Encryption at the Microscopic Scale

    CERN Document Server

    Li, Haoyu; Muniraj, Inbarasan; Schroeder, Bryce C; Sheridan, John T; Jia, Shu

    2016-01-01

    We report a light-field based method that allows the optical encryption of three-dimensional (3D) volumetric information at the microscopic scale in a single 2D light-field image. The system consists of a microlens array and an array of random phase/amplitude masks. The method utilizes a wave optics model to account for the dominant diffraction effect at this new scale, and the system point-spread function (PSF) serves as the key for encryption and decryption. We successfully developed and demonstrated a deconvolution algorithm to retrieve spatially multiplexed discrete and continuous volumetric data from 2D light-field images. Showing that the method is practical for data transmission and storage, we obtained a faithful reconstruction of the 3D volumetric information from a digital copy of the encrypted light-field image. The method represents a new level of optical encryption, paving the way for broad industrial and biomedical applications in processing and securing 3D data at the microscopic scale.

  4. Volumetric Light-field Encryption at the Microscopic Scale.

    Science.gov (United States)

    Li, Haoyu; Guo, Changliang; Muniraj, Inbarasan; Schroeder, Bryce C; Sheridan, John T; Jia, Shu

    2017-01-06

    We report a light-field based method that allows the optical encryption of three-dimensional (3D) volumetric information at the microscopic scale in a single 2D light-field image. The system consists of a microlens array and an array of random phase/amplitude masks. The method utilizes a wave optics model to account for the dominant diffraction effect at this new scale, and the system point-spread function (PSF) serves as the key for encryption and decryption. We successfully developed and demonstrated a deconvolution algorithm to retrieve both spatially multiplexed discrete data and continuous volumetric data from 2D light-field images. Showing that the method is practical for data transmission and storage, we obtained a faithful reconstruction of the 3D volumetric information from a digital copy of the encrypted light-field image. The method represents a new level of optical encryption, paving the way for broad industrial and biomedical applications in processing and securing 3D data at the microscopic scale.

  5. Variable displacement alpha-type Stirling engine

    Science.gov (United States)

    Homutescu, V. M.; Bălănescu, D. T.; Panaite, C. E.; Atanasiu, M. V.

    2016-08-01

    The basic design and construction of an alpha-type Stirling engine with on load variable displacement is presented. The variable displacement is obtained through a planar quadrilateral linkage with one on load movable ground link. The physico-mathematical model used for analyzing the variable displacement alpha-type Stirling engine behavior is an isothermal model that takes into account the real movement of the pistons. Performances and power adjustment capabilities of such alpha-type Stirling engine are calculated and analyzed. An exemplification through the use of the numerical simulation was performed in this regard.

  6. Epitaxial growth by monolayer restricted galvanic displacement

    Directory of Open Access Journals (Sweden)

    Vasilić Rastko

    2012-01-01

    Full Text Available The development of a new method for epitaxial growth of metals in solution by galvanic displacement of layers pre-deposited by underpotential deposition (UPD was discussed and experimentally illustrated throughout the lecture. Cyclic voltammetry (CV and scanning tunneling microscopy (STM are employed to carry out and monitor a “quasi-perfect”, two-dimensional growth of Ag on Au(111, Cu on Ag(111, and Cu on Au(111 by repetitive galvanic displacement of underpotentially deposited monolayers. A comparative study emphasizes the displacement stoichiometry as an efficient tool for thickness control during the deposition process and as a key parameter that affects the deposit morphology. The excellent quality of layers deposited by monolayer-restricted galvanic displacement is manifested by a steady UPD voltammetry and ascertained by a flat and uniform surface morphology maintained during the entire growth process.

  7. Assisting the return of displaced Dinka Bor

    Directory of Open Access Journals (Sweden)

    Paul Murphy

    2005-11-01

    Full Text Available The issues involved in supporting the return of internally displaced Dinka Bor communities highlight the complex, and often ignored, challenges of addressing the consequencesof South-South conflict.

  8. Displacement and deformation analysis for uplift piles

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    On the assumptions that the shear resistance increases linearly with increasing shear displacement between the uplift pile and surrounding soil,that the axis force is distributed as parabola along the pile length,that elastic distortion occurs when the pile is loaded,that the displacement of pile is in accord with that of the soil,and that the uplift pile failure is regarded as the soil failure,arational calculation method was proposed for calculating the deformation,ultimate displacement and shear resistance of piles.The distributions of frictional resistance and the shear displacement along the pile length were obtained with the method.The comparisons were made between the measurement results and the present results.The present theoretical results agree well with the measurement results,with the average difference being less than 12% before failure.The comparisons show that the proposed method is reasonable for uplift design and engineering construction of piles.

  9. Variance and covariance of accumulated displacement estimates.

    Science.gov (United States)

    Bayer, Matthew; Hall, Timothy J

    2013-04-01

    Tracking large deformations in tissue using ultrasound can enable the reconstruction of nonlinear elastic parameters, but poses a challenge to displacement estimation algorithms. Such large deformations have to be broken up into steps, each of which contributes an estimation error to the final accumulated displacement map. The work reported here measured the error variance for single-step and accumulated displacement estimates using one-dimensional numerical simulations of ultrasound echo signals, subjected to tissue strain and electronic noise. The covariance between accumulation steps was also computed. These simulations show that errors due to electronic noise are negatively correlated between steps, and therefore accumulate slowly, whereas errors due to tissue deformation are positively correlated and accumulate quickly. For reasonably low electronic noise levels, the error variance in the accumulated displacement estimates is remarkably constant as a function of step size, but increases with the length of the tracking kernel.

  10. 2014 and beyond: implications for displacement

    Directory of Open Access Journals (Sweden)

    Aidan O’Leary

    2014-05-01

    Full Text Available 2014 marks a watershed for Afghanistan, with the withdrawal of the International Security Assistance Force after twelve years, and the very real risks this withdrawal poses to the capacity of the Afghan state to meet the many internal and external challenges faced by the country. These challenges have significant implications for displaced and returning Afghans and for the potential for displacement in the future.

  11. Monolithically integrated interferometer for optical displacement measurement

    Science.gov (United States)

    Hofstetter, Daniel; Zappe, Hans P.

    1996-01-01

    We discuss the fabrication of a monolithically integrated optical displacement sensors using III-V semiconductor technology. The device is configured as a Michelson interferometer and consists of a distributed Bragg reflector laser, a photodetector and waveguides forming a directional coupler. Using this interferometer, displacements in the 100 nm range could be measured at distances of up to 45 cm. We present fabrication, device results and characterization of the completed interferometer, problems, limitations and future applications will also be discussed.

  12. Attempts to prevent displacement in the occupied Palestinian territories

    OpenAIRE

    Karim Khalil

    2012-01-01

    Prevention has become a strategy increasingly adopted by the humanitarian community in addressing forced displacement in the occupied Palestinian territories, as well as responding to immediate emergency needs for families displaced or at risk of displacement.

  13. Volumetric CT-images improve testing of radiological image interpretation skills

    Energy Technology Data Exchange (ETDEWEB)

    Ravesloot, Cécile J., E-mail: C.J.Ravesloot@umcutrecht.nl [Radiology Department at University Medical Center Utrecht, Heidelberglaan 100, 3508 GA Utrecht, Room E01.132 (Netherlands); Schaaf, Marieke F. van der, E-mail: M.F.vanderSchaaf@uu.nl [Department of Pedagogical and Educational Sciences at Utrecht University, Heidelberglaan 1, 3584 CS Utrecht (Netherlands); Schaik, Jan P.J. van, E-mail: J.P.J.vanSchaik@umcutrecht.nl [Radiology Department at University Medical Center Utrecht, Heidelberglaan 100, 3508 GA Utrecht, Room E01.132 (Netherlands); Cate, Olle Th.J. ten, E-mail: T.J.tenCate@umcutrecht.nl [Center for Research and Development of Education at University Medical Center Utrecht, Heidelberglaan 100, 3508 GA Utrecht (Netherlands); Gijp, Anouk van der, E-mail: A.vanderGijp-2@umcutrecht.nl [Radiology Department at University Medical Center Utrecht, Heidelberglaan 100, 3508 GA Utrecht, Room E01.132 (Netherlands); Mol, Christian P., E-mail: C.Mol@umcutrecht.nl [Image Sciences Institute at University Medical Center Utrecht, Heidelberglaan 100, 3508 GA Utrecht (Netherlands); Vincken, Koen L., E-mail: K.Vincken@umcutrecht.nl [Image Sciences Institute at University Medical Center Utrecht, Heidelberglaan 100, 3508 GA Utrecht (Netherlands)

    2015-05-15

    Rationale and objectives: Current radiology practice increasingly involves interpretation of volumetric data sets. In contrast, most radiology tests still contain only 2D images. We introduced a new testing tool that allows for stack viewing of volumetric images in our undergraduate radiology program. We hypothesized that tests with volumetric CT-images enhance test quality, in comparison with traditional completely 2D image-based tests, because they might better reflect required skills for clinical practice. Materials and methods: Two groups of medical students (n = 139; n = 143), trained with 2D and volumetric CT-images, took a digital radiology test in two versions (A and B), each containing both 2D and volumetric CT-image questions. In a questionnaire, they were asked to comment on the representativeness for clinical practice, difficulty and user-friendliness of the test questions and testing program. Students’ test scores and reliabilities, measured with Cronbach's alpha, of 2D and volumetric CT-image tests were compared. Results: Estimated reliabilities (Cronbach's alphas) were higher for volumetric CT-image scores (version A: .51 and version B: .54), than for 2D CT-image scores (version A: .24 and version B: .37). Participants found volumetric CT-image tests more representative of clinical practice, and considered them to be less difficult than volumetric CT-image questions. However, in one version (A), volumetric CT-image scores (M 80.9, SD 14.8) were significantly lower than 2D CT-image scores (M 88.4, SD 10.4) (p < .001). The volumetric CT-image testing program was considered user-friendly. Conclusion: This study shows that volumetric image questions can be successfully integrated in students’ radiology testing. Results suggests that the inclusion of volumetric CT-images might improve the quality of radiology tests by positively impacting perceived representativeness for clinical practice and increasing reliability of the test.

  14. Adaptive optimization by 6 DOF robotic couch in prostate volumetric IMRT treatment: rototranslational shift and dosimetric consequences.

    Science.gov (United States)

    Chiesa, Silvia; Placidi, Lorenzo; Azario, Luigi; Mattiucci, Gian Carlo; Greco, Francesca; Damiani, Andrea; Mantini, Giovanna; Frascino, Vincenzo; Piermattei, Angelo; Valentini, Vincenzo; Balducci, Mario

    2015-09-08

    The purpose of this study was to investigate the magnitude and dosimetric relevance of translational and rotational shifts on IGRT prostate volumetric-modulated arc therapy (VMAT) using Protura six degrees of freedom (DOF) Robotic Patient Positioning System. Patients with cT3aN0M0 prostate cancer, treated with VMAT simultaneous integrated boost (VMAT-SIB), were enrolled. PTV2 was obtained adding 0.7 cm margin to seminal vesicles base (CTV2), while PTV1 adding to prostate (CTV1) 0.7 cm margin in all directions, except 1.2 cm, as caudal margin. A daily CBCT was acquired before dose delivery. The translational and rotational displacements were corrected through Protura Robotic Couch, collected and applied to the simulation CT to obtain a translated CT (tCT) and a rototranslated CT (rtCT) on which we recalculated the initial treatment plan (TP). We analyzed the correlation between dosimetric coverage, organs at risk (OAR) sparing, and translational or rotational displacements. The dosimetric impact of a rototranslational correction was calculated. From October 2012 to September 2013, a total of 263 CBCT scans from 12 patients were collected. Translational shifts were errors are of dosimetric significance in sparing OAR and in target coverage. This is relevant for femoral heads and rectum because of major distance from isocenter, and for seminal vesicles because of irregular shape. No correlation was observed between translational and rotational errors. A study considering the intrafractional error and the deformable registration is ongoing.

  15. Measuring fast stochastic displacements of bio-membranes with dynamic optical displacement spectroscopy

    National Research Council Canada - National Science Library

    Monzel, C; Schmidt, D; Kleusch, C; Kirchenbüchler, D; Seifert, U; Smith, A-S; Sengupta, K; Merkel, R

    2015-01-01

    Stochastic displacements or fluctuations of biological membranes are increasingly recognized as an important aspect of many physiological processes, but hitherto their precise quantification in living...

  16. Personalized heterogeneous deformable model for fast volumetric registration.

    Science.gov (United States)

    Si, Weixin; Liao, Xiangyun; Wang, Qiong; Heng, Pheng Ann

    2017-02-20

    Biomechanical deformable volumetric registration can help improve safety of surgical interventions by ensuring the operations are extremely precise. However, this technique has been limited by the accuracy and the computational efficiency of patient-specific modeling. This study presents a tissue-tissue coupling strategy based on penalty method to model the heterogeneous behavior of deformable body, and estimate the personalized tissue-tissue coupling parameters in a data-driven way. Moreover, considering that the computational efficiency of biomechanical model is highly dependent on the mechanical resolution, a practical coarse-to-fine scheme is proposed to increase runtime efficiency. Particularly, a detail enrichment database is established in an offline fashion to represent the mapping relationship between the deformation results of high-resolution hexahedral mesh extracted from the raw medical data and a newly constructed low-resolution hexahedral mesh. At runtime, the mechanical behavior of human organ under interactions is simulated with this low-resolution hexahedral mesh, then the microstructures are synthesized in virtue of the detail enrichment database. The proposed method is validated by volumetric registration in an abdominal phantom compression experiments. Our personalized heterogeneous deformable model can well describe the coupling effects between different tissues of the phantom. Compared with high-resolution heterogeneous deformable model, the low-resolution deformable model with our detail enrichment database can achieve 9.4× faster, and the average target registration error is 3.42 mm, which demonstrates that the proposed method shows better volumetric registration performance than state-of-the-art. Our framework can well balance the precision and efficiency, and has great potential to be adopted in the practical augmented reality image-guided robotic systems.

  17. Volumetric measurements of pulmonary nodules: variability in automated analysis tools

    Science.gov (United States)

    Juluru, Krishna; Kim, Woojin; Boonn, William; King, Tara; Siddiqui, Khan; Siegel, Eliot

    2007-03-01

    Over the past decade, several computerized tools have been developed for detection of lung nodules and for providing volumetric analysis. Incidentally detected lung nodules have traditionally been followed over time by measurements of their axial dimensions on CT scans to ensure stability or document progression. A recently published article by the Fleischner Society offers guidelines on the management of incidentally detected nodules based on size criteria. For this reason, differences in measurements obtained by automated tools from various vendors may have significant implications on management, yet the degree of variability in these measurements is not well understood. The goal of this study is to quantify the differences in nodule maximum diameter and volume among different automated analysis software. Using a dataset of lung scans obtained with both "ultra-low" and conventional doses, we identified a subset of nodules in each of five size-based categories. Using automated analysis tools provided by three different vendors, we obtained size and volumetric measurements on these nodules, and compared these data using descriptive as well as ANOVA and t-test analysis. Results showed significant differences in nodule maximum diameter measurements among the various automated lung nodule analysis tools but no significant differences in nodule volume measurements. These data suggest that when using automated commercial software, volume measurements may be a more reliable marker of tumor progression than maximum diameter. The data also suggest that volumetric nodule measurements may be relatively reproducible among various commercial workstations, in contrast to the variability documented when performing human mark-ups, as is seen in the LIDC (lung imaging database consortium) study.

  18. Volumetric hemispheric ratio as a useful tool in personality psychology.

    Science.gov (United States)

    Montag, Christian; Schoene-Bake, Jan-Christoph; Wagner, Jan; Reuter, Martin; Markett, Sebastian; Weber, Bernd; Quesada, Carlos M

    2013-02-01

    The present study investigates the link between volumetric hemispheric ratios (VHRs) and personality measures in N=267 healthy participants using Eysenck's Personality Inventory-Revised (EPQ-R) and the BIS/BAS scales. A robust association between extraversion and VHRs was observed for gray matter in males but not females. Higher gray matter volume in the left than in the right hemisphere was associated with higher extraversion in males. The results are discussed in the context of positive emotionality and laterality of the human brain.

  19. AN ATTRIBUTION OF CAVITATION RESONANCE: VOLUMETRIC OSCILLATIONS OF CLOUD

    Institute of Scientific and Technical Information of China (English)

    ZUO Zhi-gang; LI Sheng-cai; LIU Shu-hong; LI Shuang; CHEN Hui

    2009-01-01

    In order to further verify the proposed theory of cavitation resonance, as well as to proceed the investigations into microscopic level, a series of studies are being carried out on the Warwick venturi. The analysis of the oscillation characteristics of the cavitation resonance has conclusively verified the macro-mechanism proposed through previous studies on other cavitating flows by the authors. The initial observations using high-speed photographic approach have revealed a new attribution of cavitation resonance. That is, the volumetric oscillation of cavitation cloud is associated with the cavitation resonance, which is a collective behaviour of the bubbles in the cloud.

  20. Synthesis of Volumetric Ring Antenna Array for Terrestrial Coverage Pattern

    Directory of Open Access Journals (Sweden)

    Alberto Reyna

    2014-01-01

    Full Text Available This paper presents a synthesis of a volumetric ring antenna array for a terrestrial coverage pattern. This synthesis regards the spacing among the rings on the planes X-Y, the positions of the rings on the plane X-Z, and uniform and concentric excitations. The optimization is carried out by implementing the particle swarm optimization. The synthesis is compared with previous designs by resulting with proper performance of this geometry to provide an accurate coverage to be applied in satellite applications with a maximum reduction of the antenna hardware as well as the side lobe level reduction.

  1. Synthesis of Volumetric Ring Antenna Array for Terrestrial Coverage Pattern

    Science.gov (United States)

    Reyna, Alberto; Panduro, Marco A.; Del Rio Bocio, Carlos

    2014-01-01

    This paper presents a synthesis of a volumetric ring antenna array for a terrestrial coverage pattern. This synthesis regards the spacing among the rings on the planes X-Y, the positions of the rings on the plane X-Z, and uniform and concentric excitations. The optimization is carried out by implementing the particle swarm optimization. The synthesis is compared with previous designs by resulting with proper performance of this geometry to provide an accurate coverage to be applied in satellite applications with a maximum reduction of the antenna hardware as well as the side lobe level reduction. PMID:24701150

  2. Estimation of volumetric breast density for breast cancer risk prediction

    Science.gov (United States)

    Pawluczyk, Olga; Yaffe, Martin J.; Boyd, Norman F.; Jong, Roberta A.

    2000-04-01

    Mammographic density (MD) has been shown to be a strong risk predictor for breast cancer. Compared to subjective assessment by a radiologist, computer-aided analysis of digitized mammograms provides a quantitative and more reproducible method for assessing breast density. However, the current methods of estimating breast density based on the area of bright signal in a mammogram do not reflect the true, volumetric quantity of dense tissue in the breast. A computerized method to estimate the amount of radiographically dense tissue in the overall volume of the breast has been developed to provide an automatic, user-independent tool for breast cancer risk assessment. The procedure for volumetric density estimation consists of first correcting the image for inhomogeneity, then performing a volume density calculation. First, optical sensitometry is used to convert all images to the logarithm of relative exposure (LRE), in order to simplify the image correction operations. The field non-uniformity correction, which takes into account heel effect, inverse square law, path obliquity and intrinsic field and grid non- uniformity is obtained by imaging a spherical section PMMA phantom. The processed LRE image of the phantom is then used as a correction offset for actual mammograms. From information about the thickness and placement of the breast, as well as the parameters of a breast-like calibration step wedge placed in the mammogram, MD of the breast is calculated. Post processing and a simple calibration phantom enable user- independent, reliable and repeatable volumetric estimation of density in breast-equivalent phantoms. Initial results obtained on known density phantoms show the estimation to vary less than 5% in MD from the actual value. This can be compared to estimated mammographic density differences of 30% between the true and non-corrected values. Since a more simplistic breast density measurement based on the projected area has been shown to be a strong indicator

  3. Volumetric 3D Display System with Static Screen

    Science.gov (United States)

    Geng, Jason

    2011-01-01

    Current display technology has relied on flat, 2D screens that cannot truly convey the third dimension of visual information: depth. In contrast to conventional visualization that is primarily based on 2D flat screens, the volumetric 3D display possesses a true 3D display volume, and places physically each 3D voxel in displayed 3D images at the true 3D (x,y,z) spatial position. Each voxel, analogous to a pixel in a 2D image, emits light from that position to form a real 3D image in the eyes of the viewers. Such true volumetric 3D display technology provides both physiological (accommodation, convergence, binocular disparity, and motion parallax) and psychological (image size, linear perspective, shading, brightness, etc.) depth cues to human visual systems to help in the perception of 3D objects. In a volumetric 3D display, viewers can watch the displayed 3D images from a completely 360 view without using any special eyewear. The volumetric 3D display techniques may lead to a quantum leap in information display technology and can dramatically change the ways humans interact with computers, which can lead to significant improvements in the efficiency of learning and knowledge management processes. Within a block of glass, a large amount of tiny dots of voxels are created by using a recently available machining technique called laser subsurface engraving (LSE). The LSE is able to produce tiny physical crack points (as small as 0.05 mm in diameter) at any (x,y,z) location within the cube of transparent material. The crack dots, when illuminated by a light source, scatter the light around and form visible voxels within the 3D volume. The locations of these tiny voxels are strategically determined such that each can be illuminated by a light ray from a high-resolution digital mirror device (DMD) light engine. The distribution of these voxels occupies the full display volume within the static 3D glass screen. This design eliminates any moving screen seen in previous

  4. Floating volumetric image formation using a dihedral corner reflector array device.

    Science.gov (United States)

    Miyazaki, Daisuke; Hirano, Noboru; Maeda, Yuki; Yamamoto, Siori; Mukai, Takaaki; Maekawa, Satoshi

    2013-01-01

    A volumetric display system using an optical imaging device consisting of numerous dihedral corner reflectors placed perpendicular to the surface of a metal plate is proposed. Image formation by the dihedral corner reflector array (DCRA) is free from distortion and focal length. In the proposed volumetric display system, a two-dimensional real image is moved by a mirror scanner to scan a three-dimensional (3D) space. Cross-sectional images of a 3D object are displayed in accordance with the position of the image plane. A volumetric image is observed as a stack of the cross-sectional images. The use of the DCRA brings compact system configuration and volumetric real image generation with very low distortion. An experimental volumetric display system including a DCRA, a galvanometer mirror, and a digital micro-mirror device was constructed to verify the proposed method. A volumetric image consisting of 1024×768×400 voxels was formed by the experimental system.

  5. Atomic displacements in bcc dilute alloys

    Indian Academy of Sciences (India)

    Hitesh Sharma; S Prakash

    2007-04-01

    We present here a systematic investigation of the atomic displacements in bcc transition metal (TM) dilute alloys. We have calculated the atomic displacements in bcc (V, Cr, Fe, Nb, Mo, Ta and W) transition metals (TMs) due to 3d, 4d and 5d TMs at the substitutional site using the Kanzaki lattice static method. Wills and Harrison interatomic potential is used to calculate the atomic force constants, the dynamical matrix and the impurity-induced forces. We have thoroughly investigated the atomic displacements using impurities from 3d, 4d and 5d series in the same host metal and the same impurity in different hosts. We have observed a systematic pattern in the atomic displacements for Cr-, Fe-, Nb-, Mo-, Ta- and W-based dilute alloys. The atomic displacements are found to increase with increase in the number of d electrons for all alloys considered except for V dilute alloys. The 3d impurities are found to be more easily dissolved in the 3d host metals than 4d or 5d TMs whereas 4d and 5d impurities show more solubility in 4d and 5d TMs. In general, the relaxation energy calculation suggests that impurities may be easily solvable in 5d TM hosts when compared to 3d or 4d TMs.

  6. Quantification of the vocal folds’ dynamic displacements

    Science.gov (United States)

    del Socorro Hernández-Montes, María; Muñoz, Silvino; De La Torre, Manuel; Flores, Mauricio; Pérez, Carlos; Mendoza-Santoyo, Fernando

    2016-05-01

    Fast dynamic data acquisition techniques are required to investigate the motional behavior of the vocal folds (VFs) when they are subjected to a steady air-flow through the trachea. High-speed digital holographic interferometry (DHI) is a non-invasive full-field-of-view technique that has proved its usefulness to study rapid and non-repetitive object movements. Hence it is an ideal technique used here to measure VF displacements and vibration patterns at 2000 fps. Analyses from a set of 200 displacement images showed that VFs’ vibration cycles are established along their width (y) and length (x). Furthermore, the maximum deformation for the right and left VFs’ area may be quantified from these images, which in itself represents an important result in the characterization of this structure. At a controlled air pressure, VF displacements fall within the range ~100-1740 nm, with a calculated precision and accuracy that yields a variation coefficient of 1.91%. High-speed acquisition of full-field images of VFs and their displacement quantification are on their own significant data in the study of their functional and physiological behavior since voice quality and production depend on how they vibrate, i.e. their displacement amplitude and frequency. Additionally, the use of high speed DHI avoids prolonged examinations and represents a significant scientific and technological alternative contribution in advancing the knowledge and working mechanisms of these tissues.

  7. Fingering phenomena during grain-grain displacement

    Science.gov (United States)

    Mello, Nathália M. P.; Paiva, Humberto A.; Combe, G.; Atman, A. P. F.

    2016-05-01

    Spontaneous formation of fingered patterns during the displacement of dense granular assemblies was experimentally reported few years ago, in a radial Hele-Shaw cell. Here, by means of discrete element simulations, we have recovered the experimental findings and extended the original study to explore the control parameters space. In particular, using assemblies of grains with different geometries (monodisperse, bidisperse, or polydisperse), we measured the macroscopic stress tensor in the samples in order to confirm some conjectures proposed in analogy with Saffman-Taylor viscous fingering phenomena for immiscible fluids. Considering an axial setup which allows to control the discharge of grains and to follow the trajectory and the pressure gradient along the displacing interface, we have applied the Darcy law for laminar flow in fluids in order to measure an "effective viscosity" for each assembly combination, in an attempt to mimic variation of the viscosity ratio between the injected/displaced fluids in the Saffman-Taylor experiment. The results corroborate the analogy with the viscous fluids displacement, with the bidisperse assembly corresponding to the less viscous geometry. But, differently to fluid case, granular fingers only develop for a specific combination of displaced/injected geometries, and we have demonstrated that it is always related with the formation of a force chain network along the finger direction.

  8. Performance of displacement ventilation in practice

    DEFF Research Database (Denmark)

    Naidenov, K.; Pitchurov, G.; Langkilde, Gunnar

    2002-01-01

    This paper presents results of a field study in offices with displacement ventilation. It comprises detailed physical measurements of the thermal environment and collection of occupants´ response at 227 workplaces. The results, both physical measurements and human response, identified draught...... as the major local discomfort in the rooms with displacement ventilation. Twenty-three percent of the occupants were daily bothered by draught. In some buildings the maintenance personnel tried to improve occupants´ thermal comfort by raising the supply air temperature or office workers themselves blocked...... the diffusers by rearranging the furniture. Half of the surveyed occupants were not satisfied with the indoor air quality. The main conclusion is that displacement ventilation needs careful design and room furnishing in order to ensure a comfortable environment. Occupants must understand the underlying...

  9. Forced displacement and women's security in Colombia.

    Science.gov (United States)

    Meertens, Donny

    2010-04-01

    In the protracted Colombian conflict, assistance to internally displaced persons has developed in the context of contradictory political processes. The Colombian government's launching of a transitional justice process in the midst of armed conflict has generated a complex situation displaying both conflict and post-conflict characteristics. The progressive Constitutional Court rulings on internal displacement, in particular the gender-sensitive Auto 092, constitute an attempt to bring together humanitarian interventions and transitional justice measures in a rights-based framework. However, the national government is reluctant to adopt them fully and local realities still hamper their integrated implementation. Displaced women, therefore, remain in an especially vulnerable position. This paper argues that gender-sensitive humanitarian interventions must take into account all of these complexities of scale and political process in order to make legal frameworks more effective at the local level. In these contexts, interventions should pay particular attention to strategies that contribute to transforming pre-existing gender regimes.

  10. Miscible, porous media displacements with density stratification.

    Science.gov (United States)

    Riaz, Amir; Meiburg, Eckart

    2004-11-01

    High accuracy, three-dimensional numerical simulations of miscible displacements with gravity override, in both homogeneous and heterogeneous porous media, are discussed for the quarter five-spot configuration. The influence of viscous and gravitational effects on the overall displacement dynamics is described in terms of the vorticity variable. Density differences influence the flow primarily by establishing a narrow gravity layer, in which the effective Peclet number is enhanced due to the higher flow rate. Although this effect plays a dominant role in homogeneous flows, it is suppressed to some extent in heterogeneous displacements. This is a result of coupling between the viscous and permeability vorticity fields. When the viscous wavelength is much larger than the permeability wavelength, gravity override becomes more effective because coupling between the viscous and permeability vorticity fields is less pronounced. Buoyancy forces of a certain magnitude can lead to a pinch-off of the gravity layer, thereby slowing it down.

  11. Overtreatment of displaced midshaft clavicle fractures

    DEFF Research Database (Denmark)

    Ban, Ilija; Nowak, Jan; Virtanen, Kaisa

    2016-01-01

    Background and purpose - The best treatment for displaced clavicle fractures has been debated for decades. Operative treatment has become more common. However, several randomized trials comparing non-operative and operative treatment have not shown any compelling evidence in favor of surgery. We...... identified the preferred treatment of displaced midshaft clavicle fractures at public hospitals in 3 countries in Scandinavia. Patients and methods - A purpose-made multiple-choice questionnaire in English was sent to all public hospitals in Denmark, Sweden, and Finland. This was addressed to the orthopedic...... surgeon responsible for treatment of clavicle fractures, and completed questionnaires were obtained from 85 of 118 hospitals. Results - In the 3 countries, 69 of the 85 hospitals that responded would treat displaced clavicle fractures operatively. Clear criteria for treatment allocation were used at 58...

  12. Volumetric display containing multiple two-dimensional color motion pictures

    Science.gov (United States)

    Hirayama, R.; Shiraki, A.; Nakayama, H.; Kakue, T.; Shimobaba, T.; Ito, T.

    2014-06-01

    We have developed an algorithm which can record multiple two-dimensional (2-D) gradated projection patterns in a single three-dimensional (3-D) object. Each recorded pattern has the individual projected direction and can only be seen from the direction. The proposed algorithm has two important features: the number of recorded patterns is theoretically infinite and no meaningful pattern can be seen outside of the projected directions. In this paper, we expanded the algorithm to record multiple 2-D projection patterns in color. There are two popular ways of color mixing: additive one and subtractive one. Additive color mixing used to mix light is based on RGB colors and subtractive color mixing used to mix inks is based on CMY colors. We made two coloring methods based on the additive mixing and subtractive mixing. We performed numerical simulations of the coloring methods, and confirmed their effectiveness. We also fabricated two types of volumetric display and applied the proposed algorithm to them. One is a cubic displays constructed by light-emitting diodes (LEDs) in 8×8×8 array. Lighting patterns of LEDs are controlled by a microcomputer board. The other one is made of 7×7 array of threads. Each thread is illuminated by a projector connected with PC. As a result of the implementation, we succeeded in recording multiple 2-D color motion pictures in the volumetric displays. Our algorithm can be applied to digital signage, media art and so forth.

  13. Volumetric three-dimensional display system with rasterization hardware

    Science.gov (United States)

    Favalora, Gregg E.; Dorval, Rick K.; Hall, Deirdre M.; Giovinco, Michael; Napoli, Joshua

    2001-06-01

    An 8-color multiplanar volumetric display is being developed by Actuality Systems, Inc. It will be capable of utilizing an image volume greater than 90 million voxels, which we believe is the greatest utilizable voxel set of any volumetric display constructed to date. The display is designed to be used for molecular visualization, mechanical CAD, e-commerce, entertainment, and medical imaging. As such, it contains a new graphics processing architecture, novel high-performance line- drawing algorithms, and an API similar to a current standard. Three-dimensional imagery is created by projecting a series of 2-D bitmaps ('image slices') onto a diffuse screen that rotates at 600 rpm. Persistence of vision fuses the slices into a volume-filling 3-D image. A modified three-panel Texas Instruments projector provides slices at approximately 4 kHz, resulting in 8-color 3-D imagery comprised of roughly 200 radially-disposed slices which are updated at 20 Hz. Each slice has a resolution of 768 by 768 pixels, subtending 10 inches. An unusual off-axis projection scheme incorporating tilted rotating optics is used to maintain good focus across the projection screen. The display electronics includes a custom rasterization architecture which converts the user's 3- D geometry data into image slices, as well as 6 Gbits of DDR SDRAM graphics memory.

  14. Volumetric breast density affects performance of digital screening mammography.

    Science.gov (United States)

    Wanders, Johanna O P; Holland, Katharina; Veldhuis, Wouter B; Mann, Ritse M; Pijnappel, Ruud M; Peeters, Petra H M; van Gils, Carla H; Karssemeijer, Nico

    2017-02-01

    To determine to what extent automatically measured volumetric mammographic density influences screening performance when using digital mammography (DM). We collected a consecutive series of 111,898 DM examinations (2003-2011) from one screening unit of the Dutch biennial screening program (age 50-75 years). Volumetric mammographic density was automatically assessed using Volpara. We determined screening performance measures for four density categories comparable to the American College of Radiology (ACR) breast density categories. Of all the examinations, 21.6% were categorized as density category 1 ('almost entirely fatty') and 41.5, 28.9, and 8.0% as category 2-4 ('extremely dense'), respectively. We identified 667 screen-detected and 234 interval cancers. Interval cancer rates were 0.7, 1.9, 2.9, and 4.4‰ and false positive rates were 11.2, 15.1, 18.2, and 23.8‰ for categories 1-4, respectively (both p-trend density categories: 85.7, 77.6, 69.5, and 61.0% for categories 1-4, respectively (p-trend density, automatically measured on digital mammograms, impacts screening performance measures along the same patterns as established with ACR breast density categories. Since measuring breast density fully automatically has much higher reproducibility than visual assessment, this automatic method could help with implementing density-based supplemental screening.

  15. Volumetric properties of human islet amyloid polypeptide in liquid water.

    Science.gov (United States)

    Brovchenko, I; Andrews, M N; Oleinikova, A

    2010-04-28

    The volumetric properties of human islet amyloid polypeptide (hIAPP) in water were studied in a wide temperature range by computer simulations. The intrinsic density rho(p) and the intrinsic thermal expansion coefficient alpha(p) of hIAPP were evaluated by taking into account the difference between the volumetric properties of hydration and bulk water. The density of hydration water rho(h) was found to decrease almost linearly with temperature upon heating and its thermal expansion coefficient was found to be notably higher than that of bulk water. The peptide surface exposed to water is more hydrophobic and its rho(h) is smaller in conformation with a larger number of intrapeptide hydrogen bonds. The two hIAPP peptides studied (with and without disulfide bridge) show negative alpha(p), which is close to zero at 250 K and decreases to approximately -1.5 x 10(-3) K(-1) upon heating to 450 K. The analysis of various structural properties of peptides shows a correlation between the intrinsic peptide volumes and the number of intrapeptide hydrogen bonds. The obtained negative values of alpha(p) can be attributed to the shrinkage of the inner voids of the peptides upon heating.

  16. Volumetric verification of multiaxis machine tool using laser tracker.

    Science.gov (United States)

    Aguado, Sergio; Samper, David; Santolaria, Jorge; Aguilar, Juan José

    2014-01-01

    This paper aims to present a method of volumetric verification in machine tools with linear and rotary axes using a laser tracker. Beyond a method for a particular machine, it presents a methodology that can be used in any machine type. Along this paper, the schema and kinematic model of a machine with three axes of movement, two linear and one rotational axes, including the measurement system and the nominal rotation matrix of the rotational axis are presented. Using this, the machine tool volumetric error is obtained and nonlinear optimization techniques are employed to improve the accuracy of the machine tool. The verification provides a mathematical, not physical, compensation, in less time than other methods of verification by means of the indirect measurement of geometric errors of the machine from the linear and rotary axes. This paper presents an extensive study about the appropriateness and drawbacks of the regression function employed depending on the types of movement of the axes of any machine. In the same way, strengths and weaknesses of measurement methods and optimization techniques depending on the space available to place the measurement system are presented. These studies provide the most appropriate strategies to verify each machine tool taking into consideration its configuration and its available work space.

  17. The Volumetric Rate of Superluminous Supernovae at z~1

    CERN Document Server

    Prajs, S; Smith, M; Levan, A; Karpenka, N V; Edwards, T D P; Walker, C R; Wolf, W M; Balland, C; Carlberg, R; Howell, A; Lidman, C; Pain, R; Pritchet, C; Ruhlmann-Kleider, V

    2016-01-01

    We present a measurement of the volumetric rate of superluminous supernovae (SLSNe) at z~1, measured using archival data from the first four years of the Canada-France-Hawaii Telescope Supernova Legacy Survey (SNLS). We develop a method for the photometric classification of SLSNe to construct our sample. Our sample includes two previously spectroscopically-identified objects, and a further new candidate selected using our classification technique. We use the point-source recovery efficiencies from Perrett et.al. (2010) and a Monte Carlo approach to calculate the rate based on our SLSN sample. We find that the three identified SLSNe from SNLS give a rate of 91 (+76/-36) SNe/Yr/Gpc^3 at a volume-weighted redshift of z=1.13. This is equivalent to 2.2 (+1.8/-0.9) x10^-4 of the volumetric core collapse supernova rate at the same redshift. When combined with other rate measurements from the literature, we show that the rate of SLSNe increases with redshift in a manner consistent with that of the cosmic star formati...

  18. DISPLACEMENT CONTROL AND KINETIC ANALYSIS OF A NOVEL VARIABLE DISPLACEMENT COMPRESSOR FOR AUTOMOTIVE AIR CONDITIONER

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    A novel variable displacement compressor (VDC) for automotive air conditioner (AAC) is introduced, which inherits the advantages of common wobble plate type VDC. It has fewer parts and makes less noise, and inst ead of pneumatic valve the displacement is controlled by electronic control valv e. In order to know the control mechanism well and get a good control effect, a mathematical model for the variable displacement mechanism is developed accordin g to the geometrical and kinematical information of the compressor. Using the mo del, the effect of relevant parameters on variable displace control is estimated . It is helpful to make the optimum decision in the flow control of AAC. As the novel displacement control device, the structure and control rule of electronic control valve is introduced. It can get better effect than the conventional pneu matic valves. And by using this new electronic control device, the optimum syste mic control of AAC is available.

  19. Passive Smoking in a Displacement Ventilated Room

    DEFF Research Database (Denmark)

    Bjørn, Erik; Nielsen, Peter V.

    The aim of this research is to see if the displacement ventilation principle can protect a person from exposure to passive tobacco smoking. This is done by full-scale experiments with two breathing thermal manikins, smoke visualisations, and tracer gas measurements. In some situations, exhaled...... smoke will stratify in a certain height due to the vertical temperature gradient. This horizontal layer of exhaled tobacco smoke may lead to exposure. In other situations, the smoke is mixed into the upper zone, and the passive smoker is protected to some extent by the displacement principle...

  20. Maxillary tooth displacement in the infratemporal fossa.

    Science.gov (United States)

    Roshanghias, Korosh; Peisker, Andre; Zieron, Jörg Olaf

    2016-01-01

    Wisdom tooth operations are sometimes accompanied by complications. This case report shows complications during upper jaw third molar removal. Expectable problems during oral surgery should be planned to be solved in advance. Displacement of the third molar during oral surgeries as a considerable complication is rarely discussed scientifically. A good design of flap, adequate power for extraction, and clear view on the surgical field are crucial. Three-dimensional radiographic diagnostics in terms of cone beam computed tomography is helpful after tooth displacement into the infratemporal fossa.

  1. Maxillary tooth displacement in the infratemporal fossa

    Directory of Open Access Journals (Sweden)

    Korosh Roshanghias

    2016-01-01

    Full Text Available Wisdom tooth operations are sometimes accompanied by complications. This case report shows complications during upper jaw third molar removal. Expectable problems during oral surgery should be planned to be solved in advance. Displacement of the third molar during oral surgeries as a considerable complication is rarely discussed scientifically. A good design of flap, adequate power for extraction, and clear view on the surgical field are crucial. Three-dimensional radiographic diagnostics in terms of cone beam computed tomography is helpful after tooth displacement into the infratemporal fossa.

  2. Bucket Foundation Response Under Various Displacement Rates

    DEFF Research Database (Denmark)

    Vaitkunaite, Evelina; Nielsen, Benjaminn Nordahl; Ibsen, Lars Bo

    2016-01-01

    in a multi-bucket foundation system. The foundation model is at a scale of approximately 1:20 prototype foundation size. The tests are performed in a pressure tank with the foundation model installed in dense sand. Based on the data, the conclusion is that the bucket foundation design in a storm case should......The present testing program aims at showing the pore pressure response around a bucket foundation skirt as well as the load and displacement change due to ten different displacement rates. Research findings are useful for a numerical model calibration focusing on the design of the upwind foundation...

  3. The Costs of Displacement in Brazil

    OpenAIRE

    Naercio Menezes-Filho

    2004-01-01

    This paper uses new data that combines information on workers’ education and earnings trajectories with information about their firms to estimate the costs of job displacement in Brazil. We find that high-tenure workers displaced from their firms during mass lay-offs suffer a long-term loss in monthly wages of about 20% per year. We show that this result is robust to different treatment of workers that leave the formal sector of the economy and is driven by the losses suffered by more educa...

  4. Histone displacement during nucleotide excision repair

    DEFF Research Database (Denmark)

    Dinant, C.; Bartek, J.; Bekker-Jensen, S.

    2012-01-01

    Nucleotide excision repair (NER) is an important DNA repair mechanism required for cellular resistance against UV light and toxic chemicals such as those found in tobacco smoke. In living cells, NER efficiently detects and removes DNA lesions within the large nuclear macromolecular complex called...... of histone variants and histone displacement (including nucleosome sliding). Here we review current knowledge, and speculate about current unknowns, regarding those chromatin remodeling activities that physically displace histones before, during and after NER. © 2012 by the authors; licensee MDPI, Basel...

  5. F2DPR: a fast and robust cross-correlation technique for volumetric PIV

    Science.gov (United States)

    Earl, Thomas; Jeon, Young Jin; Lecordier, Bertrand; David, Laurent

    2016-08-01

    The current state-of-the-art in cross-correlation based time-resolved particle image velocimetry (PIV) techniques are the fluid trajectory correlation, FTC (Lynch and Scarano 2013) and the fluid trajectory evaluation based on an ensemble-averaged cross-correlation, FTEE (Jeon et al 2014a). These techniques compute the velocity vector as a polynomial trajectory Γ in space and time, enabling the extraction of beneficial quantities such as material acceleration whilst significantly increasing the accuracy of the particle displacement prediction achieved by standard two-frame PIV. In the context of time-resolved volumetric PIV, the drawback of trajectory computation is the computational expense of the three-dimensional (3D) cross-correlation, exacerbated by the requirement to perform N  -  1 cross-correlations, where N (for typically 5≤slant N≤slant 9 ) is the number of sequential particle volumes, for each velocity field. Therefore, the acceleration of this calculation is highly desirable. This paper re-examines the application of two-dimensional (2D) cross-correlation methods to three-dimensional (3D) datasets by Bilsky et al (2011) and the binning techniques of Discetti and Astarita (2012). A new and robust version of the 2D methods is proposed and described, called fast 2D projection—re-projection (f2dpr). Performance tests based on computational time and accuracy for both two-frame and multi-frame PIV are carried out on synthetically generated data. The cases presented herein include uniaxial uniform linear displacements and shear, and simulated turbulence data. The proposed algorithm is shown to be in the order of 10 times faster than a standard 3D FFT without loss of precision for a wide range of synthetic test cases, while combining with the binning technique can yield 50 times faster computation. The algorithm is also applied to reconstructed synthetic turbulent particle fields to investigate reconstruction noise on its performance and no

  6. 24 CFR 42.350 - Relocation assistance for displaced persons.

    Science.gov (United States)

    2010-04-01

    ... described in 49 CFR part 24. A displaced person must be advised of his or her rights under the Fair Housing... of 1974 § 42.350 Relocation assistance for displaced persons. A displaced person may choose to... safety of the person or the public; or (2) The person is displaced from a “lower-income dwelling...

  7. 24 CFR 92.353 - Displacement, relocation, and acquisition.

    Science.gov (United States)

    2010-04-01

    ... U.S.C. 4201-4655) and 49 CFR part 24. A “displaced person” must be advised of his or her rights... assistance for displaced persons—(1) General. A displaced person (defined in paragraph (c)(2) of this section..., safe, and sanitary replacement dwellings not located in such areas. (2) Displaced Person. (i)...

  8. 24 CFR 882.810 - Displacement, relocation, and acquisition.

    Science.gov (United States)

    2010-04-01

    ... CFR 24.2(g)(2); or (iv) HUD determines that the person was not displaced as a direct result of... section. (c) Relocation assistance for displaced persons. A “displaced person” (defined in paragraph (g... displaced person must be advised of his or her rights under the Fair Housing Act (42 U.S.C. 3601-19) and,...

  9. 3D volumetric modeling of grapevine biomass using Tripod LiDAR

    Science.gov (United States)

    Keightley, K.E.; Bawden, G.W.

    2010-01-01

    Tripod mounted laser scanning provides the means to generate high-resolution volumetric measures of vegetation structure and perennial woody tissue for the calculation of standing biomass in agronomic and natural ecosystems. Other than costly destructive harvest methods, no technique exists to rapidly and accurately measure above-ground perennial tissue for woody plants such as Vitis vinifera (common grape vine). Data collected from grapevine trunks and cordons were used to study the accuracy of wood volume derived from laser scanning as compared with volume derived from analog measurements. A set of 10 laser scan datasets were collected for each of 36 vines from which volume was calculated using combinations of two, three, four, six and 10 scans. Likewise, analog volume measurements were made by submerging the vine trunks and cordons in water and capturing the displaced water. A regression analysis examined the relationship between digital and non-digital techniques among the 36 vines and found that the standard error drops rapidly as additional scans are added to the volume calculation process and stabilizes at the four-view geometry with an average Pearson's product moment correlation coefficient of 0.93. Estimates of digital volumes are systematically greater than those of analog volumes and can be explained by the manner in which each technique interacts with the vine tissue. This laser scanning technique yields a highly linear relationship between vine volume and tissue mass revealing a new, rapid and non-destructive method to remotely measure standing biomass. This application shows promise for use in other ecosystems such as orchards and forests. ?? 2010 Elsevier B.V.

  10. Histology-derived volumetric annotation of the human hippocampal subfields in postmortem MRI

    Science.gov (United States)

    Adler, Daniel H.; Pluta, John; Kadivar, Salmon; Craige, Caryne; Gee, James C.; Avants, Brian B.; Yushkevich, Paul A.

    2013-01-01

    Recently, there has been a growing effort to analyze the morphometry of hippocampal subfields using both in vivo and postmortem magnetic resonance imaging (MRI). However, given that boundaries between subregions of the hippocampal formation (HF) are conventionally defined on the basis of microscopic features that often lack discernible signature in MRI, subfield delineation in MRI literature has largely relied on heuristic geometric rules, the validity of which with respect to the underlying anatomy is largely unknown. The development and evaluation of such rules is challenged by the limited availability of data linking MRI appearance to microscopic hippocampal anatomy, particularly in three dimensions (3D). The present paper, for the first time, demonstrates the feasibility of labeling hippocampal subfields in a high resolution volumetric MRI dataset based directly on microscopic features extracted from histology. It uses a combination of computational techniques and manual post-processing to map subfield boundaries from a stack of histology images (obtained with 200 μm spacing and 5 μm slice thickness; stained using the Kluver-Barrera method) onto a postmortem 9.4 Tesla MRI scan of the intact, whole hippocampal formation acquired with 160 μm isotropic resolution. The histology reconstruction procedure consists of sequential application of a graph-theoretic slice stacking algorithm that mitigates the effects of distorted slices, followed by iterative affine and diffeomorphic co-registration to postmortem MRI scans of approximately 1 cm-thick tissue sub-blocks acquired with 200 μm isotropic resolution. These 1 cm blocks are subsequently co-registered to the MRI of the whole HF. Reconstruction accuracy is evaluated as the average displacement error between boundaries manually delineated in both the histology and MRI following the sequential stages of reconstruction. The methods presented and evaluated in this single-subject study can potentially be applied to

  11. A Personal Appearance Program for Displaced Homemakers.

    Science.gov (United States)

    Fiore, Ann Marie; De Long, Marilyn Revell

    1990-01-01

    A career counseling program evaluated the self-esteem of 28 displaced homemakers, then presented 3 sessions on the importance of personal appearance in hiring practices, wardrobe management, nonverbal communication, professional image, and self-concept. Analysis of participant evaluations indicated improved levels of control and confidence and…

  12. A new method for angular displacement measurement

    Institute of Scientific and Technical Information of China (English)

    Caini Zhang(张彩妮); Xiangzhao Wang(王向朝)

    2003-01-01

    We describe a new method for angular displacement measurements that is based on a Fabry-Perot inter-ferometer. A measurement accuracy of 10-s rad is obtained by use of the sinusoidal phase modulatinginterferometry. Another Fabry-Perot interferometer is used to obtain the key initial angle of incidence.

  13. Displacement pile installation effects in sand

    NARCIS (Netherlands)

    Beijer-Lundberg, A.

    2015-01-01

    Installation effects govern the post-installation behaviour of displacement piles in sand. These effects are currently not completely understood. Suitable experimental techniques to model these installation effects include field, laboratory and experimental models. In the current thesis a small-scal

  14. Heterodyne displacement interferometer, insensitive for input polarization

    NARCIS (Netherlands)

    Meskers, A.J.H.; Spronck, J.W.; Munnig Schmidt, R.H.

    2014-01-01

    Periodic nonlinearity (PNL) in displacement interferometers is a systematic error source that limits measurement accuracy. The PNL of coaxial heterodyne interferometers is highly influenced by the polarization state and orientation of the source frequencies. In this Letter, we investigate this error

  15. Displacement Ventilation by Different Types of Diffusers

    DEFF Research Database (Denmark)

    Nielsen, Peter V.; Hoff, Lars; Pedersen, Lars Germann

    The paper describes measuring results of the air movement from three different types of diffusers for displacement ventilation. Two of the diffusers are lowlevel wall mounted diffusers, one with a low and one with a high initial entrainment. The third diffuser is of the floor mounted type....

  16. Education: protecting the rights of displaced children

    Directory of Open Access Journals (Sweden)

    Suba Mahalingam

    2002-10-01

    Full Text Available UNICEF and its partners work with displaced communitiesto provide material assistance and protection, using as their basis the UN Convention on the Rights of the Child1 and other internationallegal instruments. Education has proven a valuable tool in this effort, not only making children aware of their rights but also providing a way to participate in the realisation of these rights.

  17. Displacing Media: LCD LAB Artistic Residency

    Directory of Open Access Journals (Sweden)

    Filipe Pais

    2012-12-01

    Full Text Available This review refers to an artistic residency which took place at LCD LAB -  CAAA at Guimarães, in March, exploring a strategy for media art called Media Displacement. The text introduces the strategy very briefly and describes the residency's organization, structure, processses and the results produced.

  18. Olympic scale of sport-induced displacement

    Directory of Open Access Journals (Sweden)

    Jean du Plessis

    2007-07-01

    Full Text Available The Olympic Games have displaced more than two million people in the last 20 years, disproportionately affecting particular groups such as the homeless, the poor, Roma and African-Americans. Mega-events such as the Olympic Games often leave a negative housing legacy for local populations.

  19. Comb-drive actuators for large displacements

    NARCIS (Netherlands)

    Legtenberg, Rob; Groeneveld, A.W.; Elwenspoek, M.

    1996-01-01

    The design, fabrication and experimental results of lateral-comb-drive actuators for large displacements at low driving voltages is presented. A comparison of several suspension designs is given, and the lateral large deflection behaviour of clamped - clamped beams and a folded flexure design is mod

  20. Britain's Redundancy Payments for Displaced Workers.

    Science.gov (United States)

    Root, Lawrence S.

    1987-01-01

    The Redundancy Payments Act of 1965 established the idea that an employee has property rights to a job based on years of company service. It instituted an entitlement program for displaced workers sponsored by firms and the government. The British layoff situtation differs from that of the United States. (Author/CH)

  1. Environmental conditions in displaced communities of Khartoum ...

    African Journals Online (AJOL)

    USER

    one quarter of all deaths and of the total disease burden and slightly more than one-third for children can be attributed to the ..... characteristics in Khartoum State displaced communities, 2013. (N = 662). ... Donkeys/Horses. 18. 2.7. Others. 72.

  2. Rapid mapping of volumetric machine errors using distance measurements

    Energy Technology Data Exchange (ETDEWEB)

    Krulewich, D.A.

    1998-04-01

    This paper describes a relatively inexpensive, fast, and easy to execute approach to maping the volumetric errors of a machine tool, coordinate measuring machine, or robot. An error map is used to characterize a machine or to improve its accuracy by compensating for the systematic errors. The method consists of three steps: (1) models the relationship between volumetric error and the current state of the machine, (2) acquiring error data based on distance measurements throughout the work volume; and (3)fitting the error model using the nonlinear equation for the distance. The error model is formulated from the kinematic relationship among the six degrees of freedom of error an each moving axis. Expressing each parametric error as function of position each is combined to predict the error between the functional point and workpiece, also as a function of position. A series of distances between several fixed base locations and various functional points in the work volume is measured using a Laser Ball Bar (LBB). Each measured distance is a non-linear function dependent on the commanded location of the machine, the machine error, and the location of the base locations. Using the error model, the non-linear equation is solved producing a fit for the error model Also note that, given approximate distances between each pair of base locations, the exact base locations in the machine coordinate system determined during the non-linear filling procedure. Furthermore, with the use of 2048 more than three base locations, bias error in the measuring instrument can be removed The volumetric errors of three-axis commercial machining center have been mapped using this procedure. In this study, only errors associated with the nominal position of the machine were considered Other errors such as thermally induced and load induced errors were not considered although the mathematical model has the ability to account for these errors. Due to the proprietary nature of the projects we are

  3. Drinking and displacement: a systematic review of the influence of forced displacement on harmful alcohol use.

    Science.gov (United States)

    Weaver, Heather; Roberts, Bayard

    2010-11-01

    This paper systematically reviews evidence about factors associated with harmful alcohol use amongst forcibly displaced persons, including refugees and internally displaced persons. Bibliographic and humanitarian-related databases were searched. The number of quantitative and qualitative studies that were screened and reviewed was 1108. Only 10 studies met inclusion criteria. Risk factors identified included gender, age, exposure to traumatic events and resulting posttraumatic stress disorder, prior alcohol consumption-related problems, year of immigration, location of residence, social relations, and postmigration trauma and stress. The evidence base was extremely weak, and there is a need to improve the quantity and quality of research about harmful alcohol use by forcibly displaced persons.

  4. Quantitative volumetric Raman imaging of three dimensional cell cultures

    Science.gov (United States)

    Kallepitis, Charalambos; Bergholt, Mads S.; Mazo, Manuel M.; Leonardo, Vincent; Skaalure, Stacey C.; Maynard, Stephanie A.; Stevens, Molly M.

    2017-03-01

    The ability to simultaneously image multiple biomolecules in biologically relevant three-dimensional (3D) cell culture environments would contribute greatly to the understanding of complex cellular mechanisms and cell-material interactions. Here, we present a computational framework for label-free quantitative volumetric Raman imaging (qVRI). We apply qVRI to a selection of biological systems: human pluripotent stem cells with their cardiac derivatives, monocytes and monocyte-derived macrophages in conventional cell culture systems and mesenchymal stem cells inside biomimetic hydrogels that supplied a 3D cell culture environment. We demonstrate visualization and quantification of fine details in cell shape, cytoplasm, nucleus, lipid bodies and cytoskeletal structures in 3D with unprecedented biomolecular specificity for vibrational microspectroscopy.

  5. Optimization approaches to volumetric modulated arc therapy planning

    Energy Technology Data Exchange (ETDEWEB)

    Unkelbach, Jan, E-mail: junkelbach@mgh.harvard.edu; Bortfeld, Thomas; Craft, David [Department of Radiation Oncology, Massachusetts General Hospital and Harvard Medical School, Boston, Massachusetts 02114 (United States); Alber, Markus [Department of Medical Physics and Department of Radiation Oncology, Aarhus University Hospital, Aarhus C DK-8000 (Denmark); Bangert, Mark [Department of Medical Physics in Radiation Oncology, German Cancer Research Center, Heidelberg D-69120 (Germany); Bokrantz, Rasmus [RaySearch Laboratories, Stockholm SE-111 34 (Sweden); Chen, Danny [Department of Computer Science and Engineering, University of Notre Dame, Notre Dame, Indiana 46556 (United States); Li, Ruijiang; Xing, Lei [Department of Radiation Oncology, Stanford University, Stanford, California 94305 (United States); Men, Chunhua [Department of Research, Elekta, Maryland Heights, Missouri 63043 (United States); Nill, Simeon [Joint Department of Physics at The Institute of Cancer Research and The Royal Marsden NHS Foundation Trust, London SM2 5NG (United Kingdom); Papp, Dávid [Department of Mathematics, North Carolina State University, Raleigh, North Carolina 27695 (United States); Romeijn, Edwin [H. Milton Stewart School of Industrial and Systems Engineering, Georgia Institute of Technology, Atlanta, Georgia 30332 (United States); Salari, Ehsan [Department of Industrial and Manufacturing Engineering, Wichita State University, Wichita, Kansas 67260 (United States)

    2015-03-15

    Volumetric modulated arc therapy (VMAT) has found widespread clinical application in recent years. A large number of treatment planning studies have evaluated the potential for VMAT for different disease sites based on the currently available commercial implementations of VMAT planning. In contrast, literature on the underlying mathematical optimization methods used in treatment planning is scarce. VMAT planning represents a challenging large scale optimization problem. In contrast to fluence map optimization in intensity-modulated radiotherapy planning for static beams, VMAT planning represents a nonconvex optimization problem. In this paper, the authors review the state-of-the-art in VMAT planning from an algorithmic perspective. Different approaches to VMAT optimization, including arc sequencing methods, extensions of direct aperture optimization, and direct optimization of leaf trajectories are reviewed. Their advantages and limitations are outlined and recommendations for improvements are discussed.

  6. Volumetric properties of water/AOT/isooctane microemulsions.

    Science.gov (United States)

    Du, Changfei; He, Wei; Yin, Tianxiang; Shen, Weiguo

    2014-12-23

    The densities of AOT/isooctane micelles and water/AOT/isooctane microemulsions with the molar ratios R of water to AOT being 2, 8, 10, 12, 16, 18, 20, 25, 30, and 40 were measured at 303.15 K. The apparent specific volumes of AOT and the quasi-component water/AOT at various concentrations were calculated and used to estimate the volumetric properties of AOT and water in the droplets and in the continuous oil phase, to discuss the interaction between the droplets, and to determine the critical micelle concentration and the critical microemulsion concentrations. A thermodynamic model was proposed to analysis the stability boundary of the microemulsion droplets, which confirms the maximum value of R being about 65 for the stable AOT/water/isooctane microemulsion droplets.

  7. Quantitative volumetric Raman imaging of three dimensional cell cultures

    KAUST Repository

    Kallepitis, Charalambos

    2017-03-22

    The ability to simultaneously image multiple biomolecules in biologically relevant three-dimensional (3D) cell culture environments would contribute greatly to the understanding of complex cellular mechanisms and cell–material interactions. Here, we present a computational framework for label-free quantitative volumetric Raman imaging (qVRI). We apply qVRI to a selection of biological systems: human pluripotent stem cells with their cardiac derivatives, monocytes and monocyte-derived macrophages in conventional cell culture systems and mesenchymal stem cells inside biomimetic hydrogels that supplied a 3D cell culture environment. We demonstrate visualization and quantification of fine details in cell shape, cytoplasm, nucleus, lipid bodies and cytoskeletal structures in 3D with unprecedented biomolecular specificity for vibrational microspectroscopy.

  8. In-line hologram segmentation for volumetric samples.

    Science.gov (United States)

    Orzó, László; Göröcs, Zoltán; Fehér, András; Tőkés, Szabolcs

    2013-01-01

    We propose a fast, noniterative method to segment an in-line hologram of a volumetric sample into in-line subholograms according to its constituent objects. In contrast to the phase retrieval or twin image elimination algorithms, we do not aim or require to reconstruct the complex wave field of all the objects, which would be a more complex task, but only provide a good estimate about the contribution of the particular objects to the original hologram quickly. The introduced hologram segmentation algorithm exploits the special inner structure of the in-line holograms and applies only the estimated supports and reconstruction distances of the corresponding objects as parameters. The performance of the proposed method is demonstrated and analyzed experimentally both on synthetic and measured holograms. We discussed how the proposed algorithm can be efficiently applied for object reconstruction and phase retrieval tasks.

  9. Three-Dimensional Volumetric Restoration by Structural Fat Grafting

    Science.gov (United States)

    Clauser, Luigi C.; Consorti, Giuseppe; Elia, Giovanni; Galié, Manlio; Tieghi, Riccardo

    2013-01-01

    The use of adipose tissue transfer for correction of maxillofacial defects was reported for the first time at the end of the 19th century. Structural fat grafting (SFG) was introduced as a way to improve facial esthetics and in recent years has evolved into applications in craniomaxillofacial reconstructive surgery. Several techniques have been proposed for harvesting and grafting the fat. However, owing to the damage of many adipocytes during these maneuvers, the results have not been satisfactory and have required several fat injection procedures for small corrections. The author's (L.C.) overview the application of SFG in the management of volumetric deficit in the craniomaxillofacial in patients treated with a long-term follow-up. PMID:24624259

  10. Semi-automatic volumetrics system to parcellate ROI on neocortex

    Science.gov (United States)

    Tan, Ou; Ichimiya, Tetsuya; Yasuno, Fumihiko; Suhara, Tetsuya

    2002-05-01

    A template-based and semi-automatic volumetrics system--BrainVol is build to divide the any given patient brain to neo-cortical and sub-cortical regions. The standard region is given as standard ROI drawn on a standard brain volume. After normalization between the standard MR image and the patient MR image, the sub-cortical ROIs' boundary are refined based on gray matter. The neo-cortical ROIs are refined by sulcus information that is semi-automatically marked on the patient brain. Then the segmentation is applied to 4D PET image of same patient for calculation of TAC (Time Activity Curve) by co-registration between MR and PET.

  11. Out-of-core clustering of volumetric datasets

    Institute of Scientific and Technical Information of China (English)

    GRANBERG Carl J.; LI Ling

    2006-01-01

    In this paper we present a novel method for dividing and clustering large volumetric scalar out-of-core datasets. This work is based on the Ordered Cluster Binary Tree (OCBT) structure created using a top-down or divisive clustering method. The OCBT structure allows fast and efficient sub volume queries to be made in combination with level of detail (LOD) queries of the tree. The initial partitioning of the large out-of-core dataset is done by using non-axis aligned planes calculated using Principal Component Analysis (PCA). A hybrid OCBT structure is also proposed where an in-core cluster binary tree is combined with a large out-of-core file.

  12. Volumetric Survey Speed: A Figure of Merit for Transient Surveys

    CERN Document Server

    Bellm, Eric C

    2016-01-01

    Time-domain surveys can exchange sky coverage for revisit frequency, complicating the comparison of their relative capabilities. By using different revisit intervals, a specific camera may execute surveys optimized for discovery of different classes of transient objects. We propose a new figure of merit, the instantaneous volumetric survey speed, for evaluating transient surveys. This metric defines the trade between cadence interval and snapshot survey volume and so provides a natural means of comparing survey capability. The related metric of areal survey speed imposes a constraint on the range of possible revisit times: we show that many modern time-domain surveys are limited by the amount of fresh sky available each night. We introduce the concept of "spectroscopic accessibility" and discuss its importance for transient science goals requiring followup observing. We present an extension of the control time algorithm for cases where multiple consecutive detections are required. Finally, we explore how surv...

  13. Utilization of an ultrasound beam steering angle for measurements of tissue displacement vector and lateral displacement

    Directory of Open Access Journals (Sweden)

    Chikayoshi Sumi

    2010-09-01

    Full Text Available Chikayoshi SumiDepartment of Information and Communication Sciences, Faculty of Science and Technology, Sophia University, Tokyo, JapanAbstract: A number of ultrasonic displacement/velocity measurement methods have been extensively developed for measurements of blood flow, tissue motion, and strain. Lateral modulation (LM methods have also been reported using steered, crossed beams, and these methods permit measurements of displacement vectors. In this report, a new beam steering method for the transmission and reception of ultrasound is proposed, which can enable measurements of lateral displacements and of arbitrary displacement vectors with a very high degree of accuracy. Because this beam steering method uses only a steering angle, this method is referred to as ASTA. With ASTA, the number of available methods to obtain a displacement vector measurement is limited to previously developed block-matching methods, such as the multidimensional cross-spectrum phase gradient method, and the multidimensional autocorrelation method (MAM and the multidimensional Doppler method (MDM using a block-matching method (the methods using block matching are referred to as MAMb and MDMb, respectively. Being dependent on the measurement method, only a lateral displacement measurement can be made even if the methods are multidimensional, ie, previously developed MAM and MDM using a moving average and a mirror setting of the obtained steered beams, and one-dimensional (1D, such as an autocorrelation method. Considerations of beamforming schemes using LM and ASTA show that the simple ASTA beamforming method increases capabilities for real-time measurements and requires a small physical aperture when compared with LM. For lateral displacement measurements (eg, blood flow in a carotid artery, a lateral coordinate must correspond to the direction of the target’s lateral motion, and the steering angle used is as large as possible to increase the measurement accuracy

  14. Volumetric optical coherence microscopy enabled by aberrated optics (Conference Presentation)

    Science.gov (United States)

    Mulligan, Jeffrey A.; Liu, Siyang; Adie, Steven G.

    2017-02-01

    Optical coherence microscopy (OCM) is an interferometric imaging technique that enables high resolution, non-invasive imaging of 3D cell cultures and biological tissues. Volumetric imaging with OCM suffers a trade-off between high transverse resolution and poor depth-of-field resulting from defocus, optical aberrations, and reduced signal collection away from the focal plane. While defocus and aberrations can be compensated with computational methods such as interferometric synthetic aperture microscopy (ISAM) or computational adaptive optics (CAO), reduced signal collection must be physically addressed through optical hardware. Axial scanning of the focus is one approach, but comes at the cost of longer acquisition times, larger datasets, and greater image reconstruction times. Given the capabilities of CAO to compensate for general phase aberrations, we present an alternative method to address the signal collection problem without axial scanning by using intentionally aberrated optical hardware. We demonstrate the use of an astigmatic spectral domain (SD-)OCM imaging system to enable single-acquisition volumetric OCM in 3D cell culture over an extended depth range, compared to a non-aberrated SD-OCM system. The transverse resolution of the non-aberrated and astigmatic imaging systems after application of CAO were 2 um and 2.2 um, respectively. The depth-range of effective signal collection about the nominal focal plane was increased from 100 um in the non-aberrated system to over 300 um in the astigmatic system, extending the range over which useful data may be acquired in a single OCM dataset. We anticipate that this method will enable high-throughput cellular-resolution imaging of dynamic biological systems over extended volumes.

  15. Marginal Space Deep Learning: Efficient Architecture for Volumetric Image Parsing.

    Science.gov (United States)

    Ghesu, Florin C; Krubasik, Edward; Georgescu, Bogdan; Singh, Vivek; Yefeng Zheng; Hornegger, Joachim; Comaniciu, Dorin

    2016-05-01

    Robust and fast solutions for anatomical object detection and segmentation support the entire clinical workflow from diagnosis, patient stratification, therapy planning, intervention and follow-up. Current state-of-the-art techniques for parsing volumetric medical image data are typically based on machine learning methods that exploit large annotated image databases. Two main challenges need to be addressed, these are the efficiency in scanning high-dimensional parametric spaces and the need for representative image features which require significant efforts of manual engineering. We propose a pipeline for object detection and segmentation in the context of volumetric image parsing, solving a two-step learning problem: anatomical pose estimation and boundary delineation. For this task we introduce Marginal Space Deep Learning (MSDL), a novel framework exploiting both the strengths of efficient object parametrization in hierarchical marginal spaces and the automated feature design of Deep Learning (DL) network architectures. In the 3D context, the application of deep learning systems is limited by the very high complexity of the parametrization. More specifically 9 parameters are necessary to describe a restricted affine transformation in 3D, resulting in a prohibitive amount of billions of scanning hypotheses. The mechanism of marginal space learning provides excellent run-time performance by learning classifiers in clustered, high-probability regions in spaces of gradually increasing dimensionality. To further increase computational efficiency and robustness, in our system we learn sparse adaptive data sampling patterns that automatically capture the structure of the input. Given the object localization, we propose a DL-based active shape model to estimate the non-rigid object boundary. Experimental results are presented on the aortic valve in ultrasound using an extensive dataset of 2891 volumes from 869 patients, showing significant improvements of up to 45

  16. The volumetric rate of superluminous supernovae at z ˜ 1

    Science.gov (United States)

    Prajs, S.; Sullivan, M.; Smith, M.; Levan, A.; Karpenka, N. V.; Edwards, T. D. P.; Walker, C. R.; Wolf, W. M.; Balland, C.; Carlberg, R.; Howell, D. A.; Lidman, C.; Pain, R.; Pritchet, C.; Ruhlmann-Kleider, V.

    2017-01-01

    We present a measurement of the volumetric rate of superluminous supernovae (SLSNe) at z ˜ 1.0, measured using archival data from the first four years of the Canada-France-Hawaii Telescope Supernova Legacy Survey (SNLS). We develop a method for the photometric classification of SLSNe to construct our sample. Our sample includes two previously spectroscopically identified objects, and a further new candidate selected using our classification technique. We use the point-source recovery efficiencies from Perrett et al. and a Monte Carlo approach to calculate the rate based on our SLSN sample. We find that the three identified SLSNe from SNLS give a rate of 91^{+76}_{-36} SNe yr-1 Gpc-3 at a volume-weighted redshift of z = 1.13. This is equivalent to 2.2^{+1.8}_{-0.9}× 10^{-4} of the volumetric core-collapse supernova rate at the same redshift. When combined with other rate measurements from the literature, we show that the rate of SLSNe increases with redshift in a manner consistent with that of the cosmic star formation history. We also estimate the rate of ultra-long gamma-ray bursts based on the events discovered by the Swift satellite, and show that it is comparable to the rate of SLSNe, providing further evidence of a possible connection between these two classes of events. We also examine the host galaxies of the SLSNe discovered in SNLS, and find them to be consistent with the stellar-mass distribution of other published samples of SLSNe.

  17. Volumetric analysis of corticocancellous bones using CT data

    Energy Technology Data Exchange (ETDEWEB)

    Krappinger, Dietmar; Linde, Astrid von; Rosenberger, Ralf; Blauth, Michael [Medical University Innsbruck, Department of Trauma Surgery and Sports Medicine, Innsbruck (Austria); Glodny, Bernhard; Niederwanger, Christian [Medical University Innsbruck, Department of Radiology I, Innsbruck (Austria)

    2012-05-15

    To present a method for an automated volumetric analysis of corticocancellous bones such as the superior pubic ramus using CT data and to assess the reliability of this method. Computed tomography scans of a consecutive series of 250 patients were analyzed. A Hounsfield unit (HU) thresholding-based reconstruction technique (''Vessel Tracking,'' GE Healthcare) was used. A contiguous space of cancellous bone with similar HU values between the starting and end points was automatically identified as the region of interest. The identification was based upon the density gradient to the adjacent cortical bone. The starting point was defined as the middle of the parasymphyseal corticocancellous transition zone on the axial slice showing the parasymphyseal superior pubic ramus in its maximum anteroposterior width. The end point was defined as the middle of the periarticular corticocancellous transition zone on the axial slice showing the quadrilateral plate as a thin cortical plate. The following parameters were automatically obtained on both sides: length of the center line, volume of the superior pubic ramus between the starting point and end point, minimum, maximum and mean diameter perpendicular to the center line, and mean cross-sectional area perpendicular to the center line. An automated analysis without manual adjustments was successful in 207 patients (82.8%). The center line showed a significantly greater length in female patients (67.6 mm vs 65.0 mm). The volume was greater in male patients (21.8 cm{sup 3} vs 19.4 cm{sup 3}). The intersite reliability was high with a mean difference between the left and right sides of between 0.1% (cross-sectional area) and 2.3% (volume). The method presented allows for an automated volumetric analysis of a corticocancellous bone using CT data. The method is intended to provide preoperative information for the use of intramedullary devices in fracture fixation and percutaneous cement augmentation techniques

  18. An Analysis Methodology for Stochastic Characteristic of Volumetric Error in Multiaxis CNC Machine Tool

    Directory of Open Access Journals (Sweden)

    Qiang Cheng

    2013-01-01

    Full Text Available Traditional approaches about error modeling and analysis of machine tool few consider the probability characteristics of the geometric error and volumetric error systematically. However, the individual geometric error measured at different points is variational and stochastic, and therefore the resultant volumetric error is aslo stochastic and uncertain. In order to address the stochastic characteristic of the volumetric error for multiaxis machine tool, a new probability analysis mathematical model of volumetric error is proposed in this paper. According to multibody system theory, a mean value analysis model for volumetric error is established with consideration of geometric errors. The probability characteristics of geometric errors are obtained by statistical analysis to the measured sample data. Based on probability statistics and stochastic process theory, the variance analysis model of volumetric error is established in matrix, which can avoid the complex mathematics operations during the direct differential. A four-axis horizontal machining center is selected as an illustration example. The analysis results can reveal the stochastic characteristic of volumetric error and are also helpful to make full use of the best workspace to reduce the random uncertainty of the volumetric error and improve the machining accuracy.

  19. Volumetric and two-dimensional image interpretation show different cognitive processes in learners

    NARCIS (Netherlands)

    van der Gijp, Anouk; Ravesloot, C.J.; van der Schaaf, Marieke F; van der Schaaf, Irene C; Huige, Josephine C B M; Vincken, Koen L; Ten Cate, Olle Th J; van Schaik, JPJ

    2015-01-01

    RATIONALE AND OBJECTIVES: In current practice, radiologists interpret digital images, including a substantial amount of volumetric images. We hypothesized that interpretation of a stack of a volumetric data set demands different skills than interpretation of two-dimensional (2D) cross-sectional imag

  20. High Volumetric Energy Density Hybrid Supercapacitors Based on Reduced Graphene Oxide Scrolls.

    Science.gov (United States)

    Rani, Janardhanan R; Thangavel, Ranjith; Oh, Se-I; Woo, Jeong Min; Chandra Das, Nayan; Kim, So-Yeon; Lee, Yun-Sung; Jang, Jae-Hyung

    2017-07-12

    The low volumetric energy density of reduced graphene oxide (rGO)-based electrodes limits its application in commercial electrochemical energy storage devices that require high-performance energy storage capacities in small volumes. The volumetric energy density of rGO-based electrode materials is very low due to their low packing density. A supercapacitor with enhanced packing density and high volumetric energy density is fabricated using doped rGO scrolls (GFNSs) as the electrode material. The restacking of rGO sheets is successfully controlled through synthesizing the doped scroll structures while increasing the packing density. The fabricated cell exhibits an ultrahigh volumetric energy density of 49.66 Wh/L with excellent cycling stability (>10 000 cycles). This unique design strategy for the electrode material has significant potential for the future supercapacitors with high volumetric energy densities.

  1. Global segmentation and curvature analysis of volumetric data sets using trivariate B-spline functions.

    Science.gov (United States)

    Soldea, Octavian; Elber, Gershon; Rivlin, Ehud

    2006-02-01

    This paper presents a method to globally segment volumetric images into regions that contain convex or concave (elliptic) iso-surfaces, planar or cylindrical (parabolic) iso-surfaces, and volumetric regions with saddle-like (hyperbolic) iso-surfaces, regardless of the value of the iso-surface level. The proposed scheme relies on a novel approach to globally compute, bound, and analyze the Gaussian and mean curvatures of an entire volumetric data set, using a trivariate B-spline volumetric representation. This scheme derives a new differential scalar field for a given volumetric scalar field, which could easily be adapted to other differential properties. Moreover, this scheme can set the basis for more precise and accurate segmentation of data sets targeting the identification of primitive parts. Since the proposed scheme employs piecewise continuous functions, it is precise and insensitive to aliasing.

  2. The duct selective volumetric receiver: potential for different selectivity strategies and stability issues

    Energy Technology Data Exchange (ETDEWEB)

    Garcia-Casals, X. [Universidad Pontificia Comillas-ICAI, Madrid (Spain). Dept. de Fluidos y Calor; Ajona, J.I. [Departamento de Energia Solar, Viessemann, Poligono Industrial San Marcos, Getafe (Spain)

    1999-07-01

    Recently much theoretical and experimental work has been conducted on volumetric receivers. However, not much attention has been paid to the possibilities of using different selectivity mechanisms to minimize radiation thermal losses, which are the main ones at high operating temperature. In this paper we present a duct volumetric receiver model and its results, which allow the evaluation of different selectivity strategies such as: conventional {epsilon}/{alpha}, geometry, frontal absorption and diffuse/specular reflection. We propose a new concept of selective volumetric receivers based on a solar-specular/infrared-diffuse radiative behaviour and evaluate its potential for efficiency improvement. In recent work on volumetric receivers based on simplified models, it has been concluded that the duct volumetric receiver is inherently unstable when working with high solar flux. We didn't find any unstable receiver behaviour even at very high solar fluxes, and conclude that a substantial potential for efficiency improvement exists if selectivity mechanisms are properly combined. (author)

  3. Enhanced volumetric visualization for real time 4D intraoperative ophthalmic swept-source OCT.

    Science.gov (United States)

    Viehland, Christian; Keller, Brenton; Carrasco-Zevallos, Oscar M; Nankivil, Derek; Shen, Liangbo; Mangalesh, Shwetha; Viet, Du Tran; Kuo, Anthony N; Toth, Cynthia A; Izatt, Joseph A

    2016-05-01

    Current-generation software for rendering volumetric OCT data sets based on ray casting results in volume visualizations with indistinct tissue features and sub-optimal depth perception. Recent developments in hand-held and microscope-integrated intrasurgical OCT designed for real-time volumetric imaging motivate development of rendering algorithms which are both visually appealing and fast enough to support real time rendering, potentially from multiple viewpoints for stereoscopic visualization. We report on an enhanced, real time, integrated volumetric rendering pipeline which incorporates high performance volumetric median and Gaussian filtering, boundary and feature enhancement, depth encoding, and lighting into a ray casting volume rendering model. We demonstrate this improved model implemented on graphics processing unit (GPU) hardware for real-time volumetric rendering of OCT data during tissue phantom and live human surgical imaging. We show that this rendering produces enhanced 3D visualizations of pathology and intraoperative maneuvers compared to standard ray casting.

  4. Adjustment to trauma exposure in refugee, displaced, and non-displaced Bosnian women.

    Science.gov (United States)

    Schmidt, Martina; Kravic, Nera; Ehlert, Ulrike

    2008-09-01

    The war in Bosnia resulted in the displacement of millions of civilians, most of them women. Ten years after the civil war, many of them are still living as refugees in their country of origin or abroad. Research on different refugee groups has continuously reported persistent levels of posttraumatic stress disorder (PTSD) and other mental-health problems in this population. The present study compared PTSD and self-concept in Bosnian refugee women (n = 29) with women who were internally displaced (IDP; n = 26) and non-displaced women (n = 32). Data were collected using the Bosnian Trauma Questionnaire and four scales assessing self-esteem, perceived incompetence, externality of control attribution, and persistence. IDPs scored significantly higher on PTSD symptoms, externality of control attribution and perceived incompetence, and lower on self-esteem than both refugee and non-displaced women. The level of education most strongly predicted PTSD symptom severity, followed by the type of displacement, and exposure to violence during the war. Associations of self-concept with displacement and psychopathology were inconsistent, with type of displacement predicting control attributions but not other aspects of self-concept and PTSD symptoms being partly related to perceived incompetence and self-esteem. These results support previous findings stating that, in the long run, refugees show better mental health than IDPs, and that witnessing violence is a traumatic experience strongly linked to the development of PTSD symptoms. Results further indicate that education plays an important role in the development of PTSD symptoms. Associations of control attributions and type of displacement were found; these results have not been previously documented in literature.

  5. Volumetric and two-dimensional image interpretation show different cognitive processes in learners.

    Science.gov (United States)

    van der Gijp, Anouk; Ravesloot, Cécile J; van der Schaaf, Marieke F; van der Schaaf, Irene C; Huige, Josephine C B M; Vincken, Koen L; Ten Cate, Olle Th J; van Schaik, Jan P J

    2015-05-01

    In current practice, radiologists interpret digital images, including a substantial amount of volumetric images. We hypothesized that interpretation of a stack of a volumetric data set demands different skills than interpretation of two-dimensional (2D) cross-sectional images. This study aimed to investigate and compare knowledge and skills used for interpretation of volumetric versus 2D images. Twenty radiology clerks were asked to think out loud while reading four or five volumetric computed tomography (CT) images in stack mode and four or five 2D CT images. Cases were presented in a digital testing program allowing stack viewing of volumetric data sets and changing views and window settings. Thoughts verbalized by the participants were registered and coded by a framework of knowledge and skills concerning three components: perception, analysis, and synthesis. The components were subdivided into 16 discrete knowledge and skill elements. A within-subject analysis was performed to compare cognitive processes during volumetric image readings versus 2D cross-sectional image readings. Most utterances contained knowledge and skills concerning perception (46%). A smaller part involved synthesis (31%) and analysis (23%). More utterances regarded perception in volumetric image interpretation than in 2D image interpretation (Median 48% vs 35%; z = -3.9; P Cognitive processes in volumetric and 2D cross-sectional image interpretation differ substantially. Volumetric image interpretation draws predominantly on perceptual processes, whereas 2D image interpretation is mainly characterized by synthesis. The results encourage the use of volumetric images for teaching and testing perceptual skills. Copyright © 2015 AUR. Published by Elsevier Inc. All rights reserved.

  6. Charge-displacement analysis for excited states

    Energy Technology Data Exchange (ETDEWEB)

    Ronca, Enrico, E-mail: enrico@thch.unipg.it; Tarantelli, Francesco, E-mail: francesco.tarantelli@unipg.it [Istituto CNR di Scienze e Tecnologie Molecolari, via Elce di Sotto 8, I-06123 Perugia (Italy); Dipartimento di Chimica, Biologia e Biotecnologie, Università degli Studi di Perugia, via Elce di Sotto 8, I-06123 Perugia (Italy); Pastore, Mariachiara, E-mail: chiara@thch.unipg.it; Belpassi, Leonardo; De Angelis, Filippo [Istituto CNR di Scienze e Tecnologie Molecolari, via Elce di Sotto 8, I-06123 Perugia (Italy); Angeli, Celestino; Cimiraglia, Renzo [Dipartimento di Scienze Chimiche e Farmaceutiche, Università degli Studi di Ferrara, via Borsari 46, I-44100 Ferrara (Italy)

    2014-02-07

    We extend the Charge-Displacement (CD) analysis, already successfully employed to describe the nature of intermolecular interactions [L. Belpassi et al., J. Am. Chem. Soc. 132, 13046 (2010)] and various types of controversial chemical bonds [L. Belpassi et al., J. Am. Chem. Soc. 130, 1048 (2008); N. Salvi et al., Chem. Eur. J. 16, 7231 (2010)], to study the charge fluxes accompanying electron excitations, and in particular the all-important charge-transfer (CT) phenomena. We demonstrate the usefulness of the new approach through applications to exemplary excitations in a series of molecules, encompassing various typical situations from valence, to Rydberg, to CT excitations. The CD functions defined along various spatial directions provide a detailed and insightful quantitative picture of the electron displacements taking place.

  7. Wirelessly Interrogated Position or Displacement Sensors

    Science.gov (United States)

    Woodard, Stanley E.; Taylor, Bryant D.

    2007-01-01

    Two simple position or displacement sensors based on inductance-capacitance resonant circuits have been conceived. These sensors are both powered and interrogated without use of wires and without making contact with other objects. Instead, excitation and interrogation are accomplished by means of a magnetic-field-response recorder. Both of the present position or displacement sensors consist essentially of variable rectangular parallel-plate capacitors electrically connected in series with fixed inductors. Simple inductance-capacitance circuits of the type used in these sensors are inherently robust; their basic mode of operation does not depend on maintenance of specific environmental conditions. Hence, these sensors can be used under such harsh conditions as cryogenic temperatures, high pressures, and radioactivity.

  8. Precision optical displacement measurements using biphotons

    CERN Document Server

    Lyons, Kevin; Kwiat, Paul G; Jordan, Andrew N

    2016-01-01

    We propose and examine the use of biphoton pairs, such as those created in parametric down conversion or four-wave mixing, to enhance the precision and the resolution of measuring optical displacements by position-sensitive detection. We show that the precision of measuring a small optical beam displacement with this method can be significantly enhanced by the correlation between the two photons, given the same optical mode. The improvement is largest if the correlations between the photons are strong, and falls off as the biphoton correlation weakens. More surprisingly, we find that the smallest resolvable parameter of a simple split detector scales as the inverse of the number of biphotons for small biphoton number ("Heisenberg scaling"), because the Fisher information diverges as the parameter to be estimated decreases in value. One usually sees this scaling only for systems with many entangled degrees of freedom. We discuss the transition for the split-detection scheme to the standard quantum limit scalin...

  9. Comparing anisotropic displacement parameters in protein structures.

    Science.gov (United States)

    Merritt, E A

    1999-12-01

    The increasingly widespread use of synchrotron-radiation sources and cryo-preparation of samples in macromolecular crystallography has led to a dramatic increase in the number of macromolecular structures determined at atomic or near-atomic resolution. This permits expansion of the structural model to include anisotropic displacement parameters U(ij) for individual atoms. In order to explore the physical significance of these parameters in protein structures, it is useful to be able to compare quantitatively the electron-density distribution described by the refined U(ij) values associated with corresponding crystallographically independent atoms. This paper presents the derivation of an easily calculated correlation coefficient in real space between two atoms modeled with anisotropic displacement parameters. This measure is used to investigate the degree of similarity between chemically equivalent but crystallographically independent atoms in the set of protein structural models currently available from the Protein Data Bank.

  10. Determining fault geometries from surface displacements

    Science.gov (United States)

    Volkov, D.; Voisin, C.; Ionescu, I. R.

    2016-12-01

    We study in this paper a half space linear elasticity model for surface displacements caused by slip along underground faults. We prove uniqueness of the fault location and (piecewise planar) geometry and of the slip field for a given surface displacement field.We then introduce a reconstruction algorithm for the realistic case where only a finite number of surface measurements are available.After showing how this algorithm performs on simulated data and assessing the effect of noise, we apply it to measured data. The data was recorded during slow slip events in Guerrero, Mexico. Since this is a well studied subduction zone, it is possible to compareour inferred fault geometry to other reconstructions (obtained using different techniques), found in the literature.

  11. Air displacement plethysmography: cradle to grave.

    Science.gov (United States)

    Fields, David A; Gunatilake, Ravindu; Kalaitzoglou, Evangelia

    2015-04-01

    Differences in body composition are associated with increased disease risk in various stages of life. Despite numerous available methods in assessing body composition (air displacement plethysmography, dual-energy X-ray absorptiometry, bioelectrical impedance, hydrometry, and magnetic resonance imaging), due to innate technical limitations, the ability for one singular method to track body composition over the life span (ie, infancy to adulthood) is challenging and imperfect. The primary goal of this review is to determine if there are body composition methods that can accurately track body composition from infancy into adulthood. After careful consideration and taking into account the best available scientific evidence, we feel air displacement plethysmography is the best instrument at this time for tracking body composition, starting in infancy and forward into adulthood, partly because it is the only "practical" clinical tool currently available for use during infancy. © 2015 American Society for Parenteral and Enteral Nutrition.

  12. Personal Exposure in Displacement Ventilated Rooms

    DEFF Research Database (Denmark)

    Brohus, Henrik; Nielsen, Peter Vilhelm

    1996-01-01

    Personal exposure in a displacement ventilated room is examined. The stratified flow and the considerable concentration gradients necessitate an improvement of the widely used fully mixing compartmental approach. The exposure of a seated and a standing person in proportion to the stratification...... height is examined by means of full-scale measurements. A breathing thermal manikin is used to simulate a person. It is found that the flow in the boundary layer around a person is able to a great extent to entrain and transport air from below the breathing zone. In the case of non-passive, heated...... in the lower part of the room close to the occupant. A personal exposure model for displacement ventilated rooms is proposed. The model takes the influence of gradients and the human thermal boundary layer into account. Two new quantities describing the interaction between a person and the ventilation...

  13. Cooling airflow design tool for displacement ventilation.

    OpenAIRE

    Schiavon, Stefano; Bauman, Fred

    2009-01-01

    These user notes describe how to use a spreadsheet-based (Excel 2007) version of the ASHRAE method (Chen and Glicksman 2003) for calculating the amount of design cooling airflow required for a displacement ventilation (DV) system that is providing all sensible cooling for a conditioned space. The design tool has been developed by CBE and is available on the CBE Partner website: http://www.cbe.berkeley.edu/partners/downloads.php

  14. Experiments on chemically enhanced immiscible fluid displacements

    Science.gov (United States)

    Soori, Tejaswi; Ward, Thomas

    2016-11-01

    This talk focuses on experiments conducted by displacing a vegetable oil within a capillary tube (diameter forms a stable micro-emulsion. We estimate the shear viscosity of the emulsion as a function of alkali and aqueous/oil concentrations. Separately we attempt to measure the average bulk diffusion coefficient of the emulsion in both phases which is necessary to estimate the Péclet number (Pé) and subsequent mass transport phenomena. American Chemical Society Petroleum Research Fund.

  15. Intrinsic Mean Square Displacements in Proteins

    OpenAIRE

    VURAL, Derya; Glyde, Henry R.

    2012-01-01

    The thermal mean square displacement (MSD) of hydrogen in proteins and its associated hydration water is measured by neutron scattering experiments and used an indicator of protein function. The observed MSD as currently determined depends on the energy resolution width of the neutron scattering instrument employed. We propose a method for obtaining the intrinsic MSD of H in the proteins, one that is independent of the instrument resolution width. The intrinsic MSD is defined as the infinite ...

  16. Digital image correlation: displacement accuracy estimation

    Directory of Open Access Journals (Sweden)

    Wattrisse B.

    2010-06-01

    Full Text Available The aim of this collaborative work is to study the uncertainties associated with Digital Image Correlation techniques (DIC. More specifically, the link between displacement uncertainties and several correlation parameters chosen by the user and relative to the image analysis software and several image characteristics like speckle size and image noise is emphasized. A previous work [1] has been done for situations with spatially fluctuating displacement fields which dealt with mismatch error linked to the discrepancy between the adopted shape function and the real displacement field in the subset. This present work is focused on the ultimate error regime. To ensure that there is no mismatch error, synthetic images of plane rigid body translation have been analysed. DIC softwares developed by or used in the French community were used to study a large number of settings. The first observations are: (a bias amplitude is almost always insensitive to the subset size, (b DIC formulations can be split up into two families. For the first one, the bias amplitude increases with the noise while it remains constant for the second one. For both families, the mean value of the random error increases with the noise level and with the inverse of the subset size. Furthermore, the random error decreases with the radius of the speckle for the first family, while it increases for the second one. These two different behaviours of the tested DIC package are probably due to their underlying DIC formulation (interpolation, correlation criteria, optimisation process.

  17. Automating Recession Curve Displacement Recharge Estimation.

    Science.gov (United States)

    Smith, Brennan; Schwartz, Stuart

    2017-01-01

    Recharge estimation is an important and challenging element of groundwater management and resource sustainability. Many recharge estimation methods have been developed with varying data requirements, applicable to different spatial and temporal scales. The variability and inherent uncertainty in recharge estimation motivates the recommended use of multiple methods to estimate and bound regional recharge estimates. Despite the inherent limitations of using daily gauged streamflow, recession curve displacement methods provide a convenient first-order estimate as part of a multimethod hierarchical approach to estimate watershed-scale annual recharge. The implementation of recession curve displacement recharge estimation in the United States Geologic Survey (USGS) RORA program relies on the subjective, operator-specific selection of baseflow recession events to estimate a gauge-specific recession index. This paper presents a parametric algorithm that objectively automates this tedious, subjective process, parameterizing and automating the implementation of recession curve displacement. Results using the algorithm reproduce regional estimates of groundwater recharge from the USGS Appalachian Valley and Piedmont Regional Aquifer-System Analysis, with an average absolute error of less than 2%. The algorithm facilitates consistent, completely automated estimation of annual recharge that complements more rigorous data-intensive techniques for recharge estimation. © 2016, National Ground Water Association.

  18. A reference material for dynamic displacement calibration

    Science.gov (United States)

    Davighi, A.; Hack, E.; Patterson, E.; Whelan, M.

    2010-06-01

    Calibration of displacement and strain measurement systems is an essential step in providing traceability and confidence in stress and strain distributions obtained from experiment and used to validate simulations employed in engineering design. Reference materials provide a simple, well-defined distribution of the measured quantity that can be traced to an international standard and can be used to assess the uncertainty associated with the measurement system. Previous work has established a reference material and procedure for calibrating optical systems for measuring static, in-plane strain distributions and also demonstrated its use. A new effort is in progress to extend this work to the measurement of three-dimensional displacement distributions induced by cyclic and dynamic loading, including transients and large-scale deformation. The first step in this effort has been to define both the essential and desirable attributes of a reference material for calibrating systems capable of measurements of dynamic displacement and strain. An international consortium of research laboratories, system designers, manufacturers and end-users has identified a list of attributes and members of the experimental mechanics community have been asked to weight the importance of these attributes. The attributes are being utilised to evaluate candidate designs for the reference material which have been generated through a series of brain-storming sessions within the consortium.

  19. Comparing Teaching Approaches About Maxwell's Displacement Current

    Science.gov (United States)

    Karam, Ricardo; Coimbra, Debora; Pietrocola, Maurício

    2014-08-01

    Due to its fundamental role for the consolidation of Maxwell's equations, the displacement current is one of the most important topics of any introductory course on electromagnetism. Moreover, this episode is widely used by historians and philosophers of science as a case study to investigate several issues (e.g. the theory-experiment relationship). Despite the consensus among physics educators concerning the relevance of the topic, there are many possible ways to interpret and justify the need for the displacement current term. With the goal of understanding the didactical transposition of this topic more deeply, we investigate three of its domains: (1) The historical development of Maxwell's reasoning; (2) Different approaches to justify the term insertion in physics textbooks; and (3) Four lectures devoted to introduce the topic in undergraduate level given by four different professors. By reflecting on the differences between these three domains, significant evidence for the knowledge transformation caused by the didactization of this episode is provided. The main purpose of this comparative analysis is to assist physics educators in developing an epistemological surveillance regarding the teaching and learning of the displacement current.

  20. International Monetary Fund and aid displacement.

    Science.gov (United States)

    Stuckler, David; Basu, Sanjay; McKee, Martin

    2011-01-01

    Several recent papers find evidence that global health aid is being diverted to reserves, education, military, or other sectors, and is displacing government spending. This is suggested to occur because ministers of finance have competing, possibly corrupt, priorities and deprive the health sector of resources. Studies have found that development assistance for health routed to governments has a negative impact on health spending and that similar assistance routed to private nongovernmental organizations has a positive impact. An alternative hypothesis is that World Bank and IMF macro-economic policies, which specifically advise governments to divert aid to reserves to cope with aid volatility and keep government spending low, could be causing the displacement of health aid. This article evaluates whether aid displacement was greater when countries undertook a new borrowing program from the IMF between 1996 and 2006. As found in existing studies, for each $1 of development assistance for health, about $0.37 is added to the health system. However, evaluating IMF-borrowing versus non-IMF-borrowing countries reveals that non-borrowers add about $0.45 whereas borrowers add less than $0.01 to the health system. On average, health system spending grew at about half the speed when countries were exposed to the IMF than when they were not. It is important to take account of the political economy of global health finance when interpreting data on financial flows.

  1. Ultrasonography for non-displaced and mini-displaced humeral lateral condyle fractures in children

    Institute of Scientific and Technical Information of China (English)

    ZHANG Jing-dong; CHEN Hua

    2008-01-01

    Objective: To evaluate the value of ultrasonography in non-displaced and mini-displaced humeral lateral condyle fractures in children.Methods: Nine children aged 2-9 years with non-displaced or mini-displaced humeral lateral condyle fractures were examined by high-resolution ultrasonography.The fracture line through the joint surface was visualized by ultrasonography in 6 case,in which closed reduction and percutaneous pinning was performed on 3 patients and other 3 patients did not receive the treatment because of patients' or their parents'refusal.In the remaining 3 children,ultrasonography did not reveal the cartilaginous trochle involvement at the joint surface and conservative treatment was adopted.Results: The average follow-up period was 8 months.The sonographic findings were confirmed by magnetic resonance imaging in one child who received conservative treatment and another child who received percutaneous pinning.The elbow function and fractttre healing were good in cases received closed reduction and percutaneous pinning.Among the three cases who refused to receive closed reduction and internal f'txation,re-displacement occurred in 1 case and delayed union in 1 case.All three cases receiving conservative treatment had good results both in elbow function and fracture healing.Conclusion: High-resolution ultrasonography enable to reveal non-displaced and mini-displaced humeral lateral condyle fractures as well as to ascertain whether the cartilaginous trochlea humeri was involved.For these cases,arthrography or magnetic resonance imaging is unnecessary.

  2. Volumetric Spectroscopic Imaging of Glioblastoma Multiforme Radiation Treatment Volumes

    Energy Technology Data Exchange (ETDEWEB)

    Parra, N. Andres [Department of Radiation Oncology, University of Miami Miller School of Medicine, Miami, Florida (United States); Maudsley, Andrew A. [Department of Radiology, University of Miami Miller School of Medicine, Miami, Florida (United States); Gupta, Rakesh K. [Department of Radiology and Imaging, Fortis Memorial Research Institute, Gurgaon, Haryana (India); Ishkanian, Fazilat; Huang, Kris [Department of Radiation Oncology, University of Miami Miller School of Medicine, Miami, Florida (United States); Walker, Gail R. [Biostatistics and Bioinformatics Core Resource, Sylvester Cancer Center, University of Miami Miller School of Medicine, Miami, Florida (United States); Padgett, Kyle [Department of Radiation Oncology, University of Miami Miller School of Medicine, Miami, Florida (United States); Department of Radiology, University of Miami Miller School of Medicine, Miami, Florida (United States); Roy, Bhaswati [Department of Radiology and Imaging, Fortis Memorial Research Institute, Gurgaon, Haryana (India); Panoff, Joseph; Markoe, Arnold [Department of Radiation Oncology, University of Miami Miller School of Medicine, Miami, Florida (United States); Stoyanova, Radka, E-mail: RStoyanova@med.miami.edu [Department of Radiation Oncology, University of Miami Miller School of Medicine, Miami, Florida (United States)

    2014-10-01

    Purpose: Magnetic resonance (MR) imaging and computed tomography (CT) are used almost exclusively in radiation therapy planning of glioblastoma multiforme (GBM), despite their well-recognized limitations. MR spectroscopic imaging (MRSI) can identify biochemical patterns associated with normal brain and tumor, predominantly by observation of choline (Cho) and N-acetylaspartate (NAA) distributions. In this study, volumetric 3-dimensional MRSI was used to map these compounds over a wide region of the brain and to evaluate metabolite-defined treatment targets (metabolic tumor volumes [MTV]). Methods and Materials: Volumetric MRSI with effective voxel size of ∼1.0 mL and standard clinical MR images were obtained from 19 GBM patients. Gross tumor volumes and edema were manually outlined, and clinical target volumes (CTVs) receiving 46 and 60 Gy were defined (CTV{sub 46} and CTV{sub 60}, respectively). MTV{sub Cho} and MTV{sub NAA} were constructed based on volumes with high Cho and low NAA relative to values estimated from normal-appearing tissue. Results: The MRSI coverage of the brain was between 70% and 76%. The MTV{sub NAA} were almost entirely contained within the edema, and the correlation between the 2 volumes was significant (r=0.68, P=.001). In contrast, a considerable fraction of MTV{sub Cho} was outside of the edema (median, 33%) and for some patients it was also outside of the CTV{sub 46} and CTV{sub 60}. These untreated volumes were greater than 10% for 7 patients (37%) in the study, and on average more than one-third (34.3%) of the MTV{sub Cho} for these patients were outside of CTV{sub 60}. Conclusions: This study demonstrates the potential usefulness of whole-brain MRSI for radiation therapy planning of GBM and revealed that areas of metabolically active tumor are not covered by standard RT volumes. The described integration of MTV into the RT system will pave the way to future clinical trials investigating outcomes in patients treated based on

  3. Volumetric capnography for the evaluation of chronic airways diseases

    Directory of Open Access Journals (Sweden)

    Veronez L

    2014-09-01

    Full Text Available Liliani de Fátima Veronez,1 Monica Corso Pereira,2 Silvia Maria Doria da Silva,2 Luisa Affi Barcaui,2 Eduardo Mello De Capitani,2 Marcos Mello Moreira,2 Ilma Aparecida Paschoalz2 1Department of Physical Therapy, University of Votuporanga (Educational Foundation of Votuporanga, Votuporanga, 2Department of Internal Medicine, School of Medical Sciences, State University of Campinas (UNICAMP, Campinas, Sao Paulo, BrazilBackground: Obstructive lung diseases of different etiologies present with progressive peripheral airway involvement. The peripheral airways, known as the silent lung zone, are not adequately evaluated with conventional function tests. The principle of gas washout has been used to detect pulmonary ventilation inhomogeneity and to estimate the location of the underlying disease process. Volumetric capnography (VC analyzes the pattern of CO2 elimination as a function of expired volume.Objective: To measure normalized phase 3 slopes with VC in patients with non-cystic fibrosis bronchiectasis (NCB and in bronchitic patients with chronic obstructive pulmonary disease (COPD in order to compare the slopes obtained for the groups.Methods: NCB and severe COPD were enrolled sequentially from an outpatient clinic (Hospital of the State University of Campinas. A control group was established for the NCB group, paired by sex and age. All subjects performed spirometry, VC, and the 6-Minute Walk Test (6MWT. Two comparisons were made: NCB group versus its control group, and NCB group versus COPD group. The project was approved by the ethical committee of the institution. Statistical tests used were Wilcoxon or Student’s t-test; P<0.05 was considered to be a statistically significant difference.Results: Concerning the NCB group (N=20 versus the control group (N=20, significant differences were found in body mass index and in several functional variables (spirometric, VC, 6MWT with worse results observed in the NCB group. In the comparison between

  4. Widespread Volumetric Brain Changes following Tooth Loss in Female Mice

    Science.gov (United States)

    Avivi-Arber, Limor; Seltzer, Ze'ev; Friedel, Miriam; Lerch, Jason P.; Moayedi, Massieh; Davis, Karen D.; Sessle, Barry J.

    2017-01-01

    Tooth loss is associated with altered sensory, motor, cognitive and emotional functions. These changes vary highly in the population and are accompanied by structural and functional changes in brain regions mediating these functions. It is unclear to what extent this variability in behavior and function is caused by genetic and/or environmental determinants and which brain regions undergo structural plasticity that mediates these changes. Thus, the overall goal of our research program is to identify genetic variants that control structural and functional plasticity following tooth loss. As a step toward this goal, here our aim was to determine whether structural magnetic resonance imaging (sMRI) is sensitive to detect quantifiable volumetric differences in the brains of mice of different genetic background receiving tooth extraction or sham operation. We used 67 adult female mice of 7 strains, comprising the A/J (A) and C57BL/6J (B) strains and a randomly selected sample of 5 of the 23 AXB-BXA strains (AXB1, AXB4, AXB24, BXA14, BXA24) that were produced from the A and B parental mice by recombinations and inbreeding. This panel of 25 inbred strains of genetically diverse inbred strains of mice is used for mapping chromosomal intervals throughout the genome that harbor candidate genes controlling the phenotypic variance of any trait under study. Under general anesthesia, 39 mice received extraction of 3 right maxillary molar teeth and 28 mice received sham operation. On post-extraction day 21, post-mortem whole-brain high-resolution sMRI was used to quantify the volume of 160 brain regions. Compared to sham operation, tooth extraction was associated with a significantly reduced regional and voxel-wise volumes of cortical brain regions involved in processing somatosensory, motor, cognitive and emotional functions, and increased volumes in subcortical sensorimotor and temporal limbic forebrain regions including the amygdala. Additionally, comparison of the 10 BXA14

  5. Hepatosplenic volumetric assessment at MDCT for staging liver fibrosis.

    Science.gov (United States)

    Pickhardt, Perry J; Malecki, Kyle; Hunt, Oliver F; Beaumont, Claire; Kloke, John; Ziemlewicz, Timothy J; Lubner, Meghan G

    2017-07-01

    To investigate hepatosplenic volumetry at MDCT for non-invasive prediction of hepatic fibrosis. Hepatosplenic volume analysis in 624 patients (mean age, 48.8 years; 311 M/313 F) at MDCT was performed using dedicated software and compared against pathological fibrosis stage (F0 = 374; F1 = 48; F2 = 40; F3 = 65; F4 = 97). The liver segmental volume ratio (LSVR) was defined by Couinaud segments I-III over segments IV-VIII. All pre-cirrhotic fibrosis stages (METAVIR F1-F3) were based on liver biopsy within 1 year of MDCT. LSVR and total splenic volumes increased with stage of fibrosis, with mean(±SD) values of: F0: 0.26 ± 0.06 and 215.1 ± 88.5 mm(3); F1: 0.25 ± 0.08 and 294.8 ± 153.4 mm(3); F2: 0.331 ± 0.12 and 291.6 ± 197.1 mm(3); F3: 0.39 ± 0.15 and 509.6 ± 402.6 mm(3); F4: 0.56 ± 0.30 and 790.7 ± 450.3 mm(3), respectively. Total hepatic volumes showed poor discrimination (F0: 1674 ± 320 mm(3); F4: 1631 ± 691 mm(3)). For discriminating advanced fibrosis (≥F3), the ROC AUC values for LSVR, total liver volume, splenic volume and LSVR/spleen combined were 0.863, 0.506, 0.890 and 0.947, respectively. Relative changes in segmental liver volumes and total splenic volume allow for non-invasive staging of hepatic fibrosis, whereas total liver volume is a poor predictor. Unlike liver biopsy or elastography, these CT volumetric biomarkers can be obtained retrospectively on routine scans obtained for other indications. • Regional changes in hepatic volume (LSVR) correlate well with degree of fibrosis. • Total liver volume is a very poor predictor of underlying fibrosis. • Total splenic volume is associated with the degree of hepatic fibrosis. • Hepatosplenic volume assessment is comparable to elastography for staging fibrosis. • Unlike elastography, volumetric analysis can be performed retrospectively.

  6. Volumetric and MGMT parameters in glioblastoma patients: Survival analysis

    Directory of Open Access Journals (Sweden)

    Iliadis Georgios

    2012-01-01

    Full Text Available Abstract Background In this study several tumor-related volumes were assessed by means of a computer-based application and a survival analysis was conducted to evaluate the prognostic significance of pre- and postoperative volumetric data in patients harboring glioblastomas. In addition, MGMT (O6-methylguanine methyltransferase related parameters were compared with those of volumetry in order to observe possible relevance of this molecule in tumor development. Methods We prospectively analyzed 65 patients suffering from glioblastoma (GBM who underwent radiotherapy with concomitant adjuvant temozolomide. For the purpose of volumetry T1 and T2-weighted magnetic resonance (MR sequences were used, acquired both pre- and postoperatively (pre-radiochemotherapy. The volumes measured on preoperative MR images were necrosis, enhancing tumor and edema (including the tumor and on postoperative ones, net-enhancing tumor. Age, sex, performance status (PS and type of operation were also included in the multivariate analysis. MGMT was assessed for promoter methylation with Multiplex Ligation-dependent Probe Amplification (MLPA, for RNA expression with real time PCR, and for protein expression with immunohistochemistry in a total of 44 cases with available histologic material. Results In the multivariate analysis a negative impact was shown for pre-radiochemotherapy net-enhancing tumor on the overall survival (OS (p = 0.023 and for preoperative necrosis on progression-free survival (PFS (p = 0.030. Furthermore, the multivariate analysis confirmed the importance of PS in PFS and OS of patients. MGMT promoter methylation was observed in 13/23 (43.5% evaluable tumors; complete methylation was observed in 3/13 methylated tumors only. High rate of MGMT protein positivity (> 20% positive neoplastic nuclei was inversely associated with pre-operative tumor necrosis (p = 0.021. Conclusions Our findings implicate that volumetric parameters may have a significant role in

  7. 7 CFR 1944.667 - Relocation and displacement.

    Science.gov (United States)

    2010-01-01

    ... permanent or temporary relocation of displaced persons for units repaired or rehabilitated or for individual... displaced persons. The applicant shall include in its statement of activities, a statement concerning...

  8. HIV and the internally displaced: Burundi in focus

    Directory of Open Access Journals (Sweden)

    Raquel Wexler

    2003-01-01

    Full Text Available "Special attention should also be given to the prevention of contagious and infectious diseases, including AIDS, among internally displaced persons." (Guiding Principles on InternalDisplacement, 19.3

  9. Displacement Mechanism of Polymer Flooding by Molecular Tribology

    Institute of Scientific and Technical Information of China (English)

    YANG Er-Long; SONG Kao-Ping

    2006-01-01

    @@ Whether polymer flooding can enhance displacement efficiency or not is still a problem under debate. Laboratory experiment, numerical simulation and core data analysis are the commonly used means to study polymer flooding displacement efficiency.

  10. Is competition needed for ecological character displacement? Does displacement decrease competition?

    Science.gov (United States)

    Abrams, Peter A; Cortez, Michael H

    2015-12-01

    Interspecific competition for resources is generally considered to be the selective force driving ecological character displacement, and displacement is assumed to reduce competition. Skeptics of the prevalence of character displacement often cite lack of evidence of competition. The present article uses a simple model to examine whether competition is needed for character displacement and whether displacement reduces competition. It treats systems with competing resources, and considers cases when only one consumer evolves. It quantifies competition using several different measures. The analysis shows that selection for divergence of consumers occurs regardless of the level of between-resource competition or whether the indirect interaction between the consumers is competition (-,-), mutualism (+,+), or contramensalism (+,-). Also, divergent evolution always decreases the equilibrium population size of the evolving consumer. Whether divergence of one consumer reduces or increases the impact of a subsequent perturbation of the other consumer depends on the parameters and the method chosen for measuring competition. Divergence in mutualistic interactions may reduce beneficial effects of subsequent increases in the other consumer's population. The evolutionary response is driven by an increase in the relative abundance of the resource the consumer catches more rapidly. Such an increase can occur under several types of interaction.

  11. Full-field mapping of internal strain distribution in red sandstone specimen under compression using digital volumetric speckle photography and X-ray computed tomography

    Directory of Open Access Journals (Sweden)

    Lingtao Mao

    2015-04-01

    Full Text Available It is always desirable to know the interior deformation pattern when a rock is subjected to mechanical load. Few experimental techniques exist that can represent full-field three-dimensional (3D strain distribution inside a rock specimen. And yet it is crucial that this information is available for fully understanding the failure mechanism of rocks or other geomaterials. In this study, by using the newly developed digital volumetric speckle photography (DVSP technique in conjunction with X-ray computed tomography (CT and taking advantage of natural 3D speckles formed inside the rock due to material impurities and voids, we can probe the interior of a rock to map its deformation pattern under load and shed light on its failure mechanism. We apply this technique to the analysis of a red sandstone specimen under increasing uniaxial compressive load applied incrementally. The full-field 3D displacement fields are obtained in the specimen as a function of the load, from which both the volumetric and the deviatoric strain fields are calculated. Strain localization zones which lead to the eventual failure of the rock are identified. The results indicate that both shear and tension are contributing factors to the failure mechanism.

  12. DIFFERENTIAL ANALYSIS OF VOLUMETRIC STRAINS IN POROUS MATERIALS IN TERMS OF WATER FREEZING

    Directory of Open Access Journals (Sweden)

    Rusin Z.

    2013-06-01

    Full Text Available The paper presents the differential analysis of volumetric strain (DAVS. The method allows measurements of volumetric deformations of capillary-porous materials caused by water-ice phase change. The VSE indicator (volumetric strain effect, which under certain conditions can be interpreted as the minimum degree of phase change of water contained in the material pores, is proposed. The test results (DAVS for three materials with diversified microstructure: clinker brick, calcium-silicate brick and Portland cement mortar were compared with the test results for pore characteristics obtained with the mercury intrusion porosimetry.

  13. Is there a role for the use of volumetric cone beam computed tomography in periodontics?

    Science.gov (United States)

    du Bois, A H; Kardachi, B; Bartold, P M

    2012-03-01

    Volumetric computed cone beam tomography offers a number of significant advantages over conventional intraoral and extraoral panoramic radiography, as well as computed tomography. To date, periodontal diagnosis has relied heavily on the assessment of both intraoral radiographs and extraoral panoramic radiographs. With emerging technology in radiology there has been considerable interest in the role that volumetric cone beam computed tomography might play in periodontal diagnostics. This narrative reviews the current evidence and considers whether there is a role for volumetric cone beam computed tomography in periodontics.

  14. Parkinson's disease: diagnostic utility of volumetric imaging

    Energy Technology Data Exchange (ETDEWEB)

    Lin, Wei-Che; Chen, Meng-Hsiang [Kaohsiung Chang Gung Memorial Hospital and Chang Gung University College of Medicine, Department of Diagnostic Radiology, Kaohsiung (China); Chou, Kun-Hsien [National Yang-Ming University, Brain Research Center, Taipei (China); Lee, Pei-Lin [National Yang-Ming University, Department of Biomedical Imaging and Radiological Sciences, Taipei (China); Tsai, Nai-Wen; Lu, Cheng-Hsien [Kaohsiung Chang Gung Memorial Hospital and Chang Gung University College of Medicine, Department of Neurology, Kaohsiung (China); Chen, Hsiu-Ling [Kaohsiung Chang Gung Memorial Hospital and Chang Gung University College of Medicine, Department of Diagnostic Radiology, Kaohsiung (China); National Yang-Ming University, Department of Biomedical Imaging and Radiological Sciences, Taipei (China); Hsu, Ai-Ling [National Taiwan University, Institute of Biomedical Electronics and Bioinformatics, Taipei (China); Huang, Yung-Cheng [Kaohsiung Chang Gung Memorial Hospital and Chang Gung University College of Medicine, Department of Nuclear Medicine, Kaohsiung (China); Lin, Ching-Po [National Yang-Ming University, Brain Research Center, Taipei (China); National Yang-Ming University, Department of Biomedical Imaging and Radiological Sciences, Taipei (China)

    2017-04-15

    This paper aims to examine the effectiveness of structural imaging as an aid in the diagnosis of Parkinson's disease (PD). High-resolution T{sub 1}-weighted magnetic resonance imaging was performed in 72 patients with idiopathic PD (mean age, 61.08 years) and 73 healthy subjects (mean age, 58.96 years). The whole brain was parcellated into 95 regions of interest using composite anatomical atlases, and region volumes were calculated. Three diagnostic classifiers were constructed using binary multiple logistic regression modeling: the (i) basal ganglion prior classifier, (ii) data-driven classifier, and (iii) basal ganglion prior/data-driven hybrid classifier. Leave-one-out cross validation was used to unbiasedly evaluate the predictive accuracy of imaging features. Pearson's correlation analysis was further performed to correlate outcome measurement using the best PD classifier with disease severity. Smaller volume in susceptible regions is diagnostic for Parkinson's disease. Compared with the other two classifiers, the basal ganglion prior/data-driven hybrid classifier had the highest diagnostic reliability with a sensitivity of 74%, specificity of 75%, and accuracy of 74%. Furthermore, outcome measurement using this classifier was associated with disease severity. Brain structural volumetric analysis with multiple logistic regression modeling can be a complementary tool for diagnosing PD. (orig.)

  15. Volumetric Analysis of Regional Cerebral Development in Preterm Children

    Science.gov (United States)

    Kesler, Shelli R.; Ment, Laura R.; Vohr, Betty; Pajot, Sarah K.; Schneider, Karen C.; Katz, Karol H.; Ebbitt, Timothy B.; Duncan, Charles C.; Makuch, Robert W.; Reiss, Allan L.

    2011-01-01

    Preterm birth is frequently associated with both neuropathologic and cognitive sequelae. This study examined cortical lobe, subcortical, and lateral ventricle development in association with perinatal variables and cognitive outcome. High-resolution volumetric magnetic resonance imaging scans were acquired and quantified using advanced image processing techniques. Seventy-three preterm and 33 term control children ages 7.3-11.4 years were included in the study. Results indicated disproportionately enlarged parietal and frontal gray matter, occipital horn, and ventricular body, as well as reduced temporal and subcortical gray volumes in preterm children compared with control subjects. Birth weight was negatively correlated with parietal and frontal gray, as well as occipital horn volumes. Intraventricular hemorrhage was associated with reduced subcortical gray matter. Ventricular cerebrospinal fluid was negatively correlated with subcortical gray matter volumes but not with white matter volumes. Maternal education was the strongest predictor of cognitive function in the preterm group. Preterm birth appears to be associated with disorganized cortical development, possibly involving disrupted synaptic pruning and neural migration. Lower birth weight and the presence of intraventricular hemorrhage may increase the risk for neuroanatomic abnormality. PMID:15519112

  16. Volumetric microscale particle tracking velocimetry (PTV) in porous media

    Science.gov (United States)

    Guo, Tianqi; Aramideh, Soroush; Ardekani, Arezoo M.; Vlachos, Pavlos P.

    2016-11-01

    The steady-state flow through refractive-index-matched glass bead microchannels is measured using microscopic particle tracking velocimetry (μPTV). A novel technique is developed to volumetrically reconstruct particles from oversampled two-dimensional microscopic images of fluorescent particles. Fast oversampling of the quasi-steady-state flow field in the lateral direction is realized by a nano-positioning piezo stage synchronized with a fast CMOS camera. Experiments at different Reynolds numbers are carried out for flows through a series of both monodispersed and bidispersed glass bead microchannels with various porosities. The obtained velocity fields at pore-scale (on the order of 10 μm) are compared with direct numerical simulations (DNS) conducted in the exact same geometries reconstructed from micro-CT scans of the glass bead microchannels. The developed experimental method would serve as a new approach for exploring the flow physics at pore-scale in porous media, and also provide benchmark measurements for validation of numerical simulations.

  17. Buoyancy Driven Mixing with Continuous Volumetric Energy Deposition

    Science.gov (United States)

    Wachtor, Adam J.; Jebrail, Farzaneh F.; Dennisen, Nicholas A.; Andrews, Malcolm J.; Gore, Robert A.

    2014-11-01

    An experiment involving a miscible fluid pair is presented which transitioned from a Rayleigh-Taylor (RT) stable to RT unstable configuration through continuous volumetric energy deposition (VED) by microwave radiation. Initially a light, low microwave absorbing fluid rested above a heavier, more absorbing fluid. The alignment of the density gradient with gravity made the system stable, and the Atwood number (At) for the initial setup was approximately -0.12. Exposing the fluid pair to microwave radiation preferentially heated the bottom fluid, and caused its density to drop due to thermal expansion. As heating of the bottom fluid continued, the At varied from negative to positive, and after the system passed through the neutral stability point, At = 0, buoyancy driven mixing ensued. Continuous VED caused the At to continue increasing and further drive the mixing process. Successful VED mixing required careful design of the fluid pair used in the experiment. Therefore, fluid selection is discussed, along with challenges and limitations of data collection using the experimental microwave facility. Experimental and model predictions of the neutral stability point, and onset of buoyancy driven mixing, are compared, and differences with classical, constant At RT driven turbulence are discussed.

  18. FELIX 3D display: an interactive tool for volumetric imaging

    Science.gov (United States)

    Langhans, Knut; Bahr, Detlef; Bezecny, Daniel; Homann, Dennis; Oltmann, Klaas; Oltmann, Krischan; Guill, Christian; Rieper, Elisabeth; Ardey, Goetz

    2002-05-01

    The FELIX 3D display belongs to the class of volumetric displays using the swept volume technique. It is designed to display images created by standard CAD applications, which can be easily imported and interactively transformed in real-time by the FELIX control software. The images are drawn on a spinning screen by acousto-optic, galvanometric or polygon mirror deflection units with integrated lasers and a color mixer. The modular design of the display enables the user to operate with several equal or different projection units in parallel and to use appropriate screens for the specific purpose. The FELIX 3D display is a compact, light, extensible and easy to transport system. It mainly consists of inexpensive standard, off-the-shelf components for an easy implementation. This setup makes it a powerful and flexible tool to keep track with the rapid technological progress of today. Potential applications include imaging in the fields of entertainment, air traffic control, medical imaging, computer aided design as well as scientific data visualization.

  19. Toward a Philosophy and Theory of Volumetric Nonthermal Processing.

    Science.gov (United States)

    Sastry, Sudhir K

    2016-06-01

    Nonthermal processes for food preservation have been under intensive investigation for about the past quarter century, with varying degrees of success. We focus this discussion on two volumetrically acting nonthermal processes, high pressure processing (HPP) and pulsed electric fields (PEF), with emphasis on scientific understanding of each, and the research questions that need to be addressed for each to be more successful in the future. We discuss the character or "philosophy" of food preservation, with a question about the nature of the kill step(s), and the sensing challenges that need to be addressed. For HPP, key questions and needs center around whether its nonthermal effectiveness can be increased by increased pressures or pulsing, the theoretical treatment of rates of reaction as influenced by pressure, the assumption of uniform pressure distribution, and the need for (and difficulties involved in) in-situ measurement. For PEF, the questions include the rationale for pulsing, difficulties involved in continuous flow treatment chambers, the difference between electroporation theory and experimental observations, and the difficulties involved in in-situ measurement and monitoring of electric field distribution.

  20. Optical artefact characterization and correction in volumetric scintillation dosimetry

    Science.gov (United States)

    Robertson, Daniel; Hui, Cheukkai; Archambault, Louis; Mohan, Radhe; Beddar, Sam

    2014-01-01

    The goals of this study were (1) to characterize the optical artefacts affecting measurement accuracy in a volumetric liquid scintillator detector, and (2) to develop methods to correct for these artefacts. The optical artefacts addressed were photon scattering, refraction, camera perspective, vignetting, lens distortion, the lens point spread function, stray radiation, and noise in the camera. These artefacts were evaluated by theoretical and experimental means, and specific correction strategies were developed for each artefact. The effectiveness of the correction methods was evaluated by comparing raw and corrected images of the scintillation light from proton pencil beams against validated Monte Carlo calculations. Blurring due to the lens and refraction at the scintillator tank-air interface were found to have the largest effect on the measured light distribution, and lens aberrations and vignetting were important primarily at the image edges. Photon scatter in the scintillator was not found to be a significant source of artefacts. The correction methods effectively mitigated the artefacts, increasing the average gamma analysis pass rate from 66% to 98% for gamma criteria of 2% dose difference and 2 mm distance to agreement. We conclude that optical artefacts cause clinically meaningful errors in the measured light distribution, and we have demonstrated effective strategies for correcting these optical artefacts.

  1. An MRI-based semiautomated volumetric quantification of hip osteonecrosis

    Energy Technology Data Exchange (ETDEWEB)

    Malizos, K.N.; Siafakas, M.S.; Karachalios, T.S. [Dept. of Orthopaedics, Univ. of Thessalia, Larissa (Greece); Fotiadis, D.I. [Dept. of Computer Science, Univ. of Ioannina (Greece); Soucacos, P.N. [Dept. of Orthopaedic Surgery, Univ. of Ioannina (Greece)

    2001-12-01

    Objective: To objectively and precisely define the spatial distribution of osteonecrosis and to investigate the influence of various factors including etiology. Design: A volumetric method is presented to describe the size and spatial distribution of necrotic lesions of the femoral head, using MRI scans. The technique is based on the definition of an equivalent sphere model for the femoral head. Patients: The gender, age, number of hips involved, disease duration, pain intensity, limping disability and etiology were correlated with the distribution of the pathologic bone. Seventy-nine patients with 122 hips affected by osteonecrosis were evaluated. Results: The lesion size ranged from 7% to 73% of the sphere equivalent. The lateral octants presented considerable variability, ranging from wide lateral lesions extending beyond the lip of the acetabulum, to narrow medial lesions, leaving a lateral supporting pillar of intact bone. Patients with sickle cell disease and steroid administration presented the largest lesions. The extent of the posterior superior medial octant involvement correlated with the symptom intensity, a younger age and male gender. Conclusion: The methodology presented here has proven a reliable and straightforward imaging tool for precise assessment of necrotic lesions. It also enables us to target accurately the drilling and grafting procedures. (orig.)

  2. Illustration-inspired depth enhanced volumetric medical visualization.

    Science.gov (United States)

    Svakhine, Nikolai A; Ebert, David S; Andrews, William M

    2009-01-01

    Volume illustration can be used to provide insight into source data from CT/MRI scanners in much the same way as medical illustration depicts the important details of anatomical structures. As such, proven techniques used in medical illustration should be transferable to volume illustration, providing scientists with new tools to visualize their data. In recent years, a number of techniques have been developed to enhance the rendering pipeline and create illustrative effects similar to the ones found in medical textbooks and surgery manuals. Such effects usually highlight important features of the subject while subjugating its context and providing depth cues for correct perception. Inspired by traditional visual and line-drawing techniques found in medical illustration, we have developed a collection of fast algorithms for more effective emphasis/de-emphasis of data as well as conveyance of spatial relationships. Our techniques utilize effective outlining techniques and selective depth enhancement to provide perceptual cues of object importance as well as spatial relationships in volumetric datasets. Moreover, we have used illustration principles to effectively combine and adapt basic techniques so that they work together to provide consistent visual information and a uniform style.

  3. Connectivity network measures predict volumetric atrophy in mild cognitive impairment.

    Science.gov (United States)

    Nir, Talia M; Jahanshad, Neda; Toga, Arthur W; Bernstein, Matt A; Jack, Clifford R; Weiner, Michael W; Thompson, Paul M

    2015-01-01

    Alzheimer's disease (AD) is characterized by cortical atrophy and disrupted anatomic connectivity, and leads to abnormal interactions between neural systems. Diffusion-weighted imaging (DWI) and graph theory can be used to evaluate major brain networks and detect signs of a breakdown in network connectivity. In a longitudinal study using both DWI and standard magnetic resonance imaging (MRI), we assessed baseline white-matter connectivity patterns in 30 subjects with mild cognitive impairment (MCI, mean age 71.8 ± 7.5 years, 18 males and 12 females) from the Alzheimer's Disease Neuroimaging Initiative. Using both standard MRI-based cortical parcellations and whole-brain tractography, we computed baseline connectivity maps from which we calculated global "small-world" architecture measures, including mean clustering coefficient and characteristic path length. We evaluated whether these baseline network measures predicted future volumetric brain atrophy in MCI subjects, who are at risk for developing AD, as determined by 3-dimensional Jacobian "expansion factor maps" between baseline and 6-month follow-up anatomic scans. This study suggests that DWI-based network measures may be a novel predictor of AD progression.

  4. Femoral head osteonecrosis: Volumetric MRI assessment and outcome

    Energy Technology Data Exchange (ETDEWEB)

    Bassounas, Athanasios E. [Department of Medical Physics, School of Medicine, University of Ioannina, GR 451 10 Ioannina (Greece); Karantanas, Apostolos H. [Department of Radiology, School of Medicine, University of Crete, Heraklion, GR 711 10 (Greece); Fotiadis, Dimitrios I. [Unit of Medical Technology and Intelligent Information Systems, Department of Computer Science, University of Ioannina and Biomedical Research Institute-FORTH, GR 451 10 Ioannina (Greece); Malizos, Konstantinos N. [Orthopaedic Department, Medical School, University of Thessalia, GR 412 22 Larissa (Greece)]. E-mail: kmalizos@otenet.gr

    2007-07-15

    Effective treatment of femoral head osteonecrosis (FHON) requires early diagnosis and accurate assessment of the disease severity. The ability to predict in the early stages the risk of collapse is important for selecting a joint salvage procedure. The aim of the present study was to evaluate the outcome in patients treated with vascularized fibular grafts in relation to preoperative MR imaging volumetry. We studied 58 patients (87 hips) with FHON. A semi-automated octant-based lesion measurement method, previously described, was performed on the T1-w MR images. The mean time of postoperative follow-up was 7.8 years. Sixty-three hips were successful and 24 failed and converted to total hip arthroplasty within a period of 2-4 years after the initial operation. The rate of failures for hips of male patients was higher than in female patients. The mean lesion size was 28% of the sphere equivalent of the femoral head, 24 {+-} 12% for the successful hips and 37 {+-} 9% for the failed (p < 0.001). The most affected octants were antero-supero-medial (58 {+-} 26%) and postero-supero-medial (54 {+-} 31%). All but postero-infero-medial and postero-infero-lateral octants, showed statistically significant differences in the lesion size between patients with successful and failed hips. In conclusion, the volumetric analysis of preoperative MRI provides useful information with regard to a successful outcome in patients treated with vascularized fibular grafts.

  5. Three-dimensional volumetric quantification of fat loss following cryolipolysis.

    Science.gov (United States)

    Garibyan, Lilit; Sipprell, William H; Jalian, H Ray; Sakamoto, Fernanda H; Avram, Mathew; Anderson, R Rox

    2014-02-01

    Cryolipolysis is a noninvasive and well-tolerated treatment for reduction of localized subcutaneous fat. Although several studies demonstrate the safety and efficacy of this procedure, volumetric fat reduction from this treatment has not been quantified. This prospective study investigated the change in volume of fat after cryolipolysis treatment using three-dimensional (3D) photography. A prospective study of subjects treated with cryolipolysis on the flank (love handle) was performed at Massachusetts General Hospital. Volume measurements were performed with a Canfield Scientific Vectra three-dimensional camera and software to evaluate the amount of post procedure volume change. Clinical outcomes were assessed with caliper measurements, subject surveys, and blinded physician assessment of photographs. Eleven subjects were enrolled in this study. Each subject underwent a single cycle of cryolipolysis to one flank. The untreated flank served as an internal control. The follow-up time after treatment was 2 months. The mean amount of calculated absolute fat volume loss using 3D photography from baseline to 2 months follow-up visit was 56.2 ± 25.6 from the treatment site and 16.6 ± 17.6 cc from the control (P fat removal methodology that on average leads to 39.6 cc of fat loss of the treated flank at 2 months after a single treatment cycle. © 2013 Wiley Periodicals, Inc.

  6. Cortical thickness and brain volumetric analysis in body dysmorphic disorder.

    Science.gov (United States)

    Madsen, Sarah K; Zai, Alex; Pirnia, Tara; Arienzo, Donatello; Zhan, Liang; Moody, Teena D; Thompson, Paul M; Feusner, Jamie D

    2015-04-30

    Individuals with body dysmorphic disorder (BDD) suffer from preoccupations with perceived defects in physical appearance, causing severe distress and disability. Although BDD affects 1-2% of the population, the neurobiology is not understood. Discrepant results in previous volumetric studies may be due to small sample sizes, and no study has investigated cortical thickness in BDD. The current study is the largest neuroimaging analysis of BDD. Participants included 49 medication-free, right-handed individuals with DSM-IV BDD and 44 healthy controls matched by age, sex, and education. Using high-resolution T1-weighted magnetic resonance imaging, we computed vertex-wise gray matter (GM) thickness on the cortical surface and GM volume using voxel-based morphometry. We also computed volumes in cortical and subcortical regions of interest. In addition to group comparisons, we investigated associations with symptom severity, insight, and anxiety within the BDD group. In BDD, greater anxiety was significantly associated with thinner GM in the left superior temporal cortex and greater GM volume in the right caudate nucleus. There were no significant differences in cortical thickness, GM volume, or volumes in regions of interest between BDD and control subjects. Subtle associations with clinical symptoms may characterize brain morphometric patterns in BDD, rather than large group differences in brain structure. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  7. Region-of-interest volumetric visual hull refinement

    KAUST Repository

    Knoblauch, Daniel

    2010-01-01

    This paper introduces a region-of-interest visual hull refinement technique, based on flexible voxel grids for volumetric visual hull reconstructions. Region-of-interest refinement is based on a multipass process, beginning with a focussed visual hull reconstruction, resulting in a first 3D approximation of the target, followed by a region-of-interest estimation, tasked with identifying features of interest, which in turn are used to locally refine the voxel grid and extract a higher-resolution surface representation for those regions. This approach is illustrated for the reconstruction of avatars for use in tele-immersion environments, where head and hand regions are of higher interest. To allow reproducability and direct comparison a publicly available data set for human visual hull reconstruction is used. This paper shows that region-of-interest reconstruction of the target is faster and visually comparable to higher resolution focused visual hull reconstructions. This approach reduces the amount of data generated through the reconstruction, allowing faster post processing, as rendering or networking of the surface voxels. Reconstruction speeds support smooth interactions between the avatar and the virtual environment, while the improved resolution of its facial region and hands creates a higher-degree of immersion and potentially impacts the perception of body language, facial expressions and eye-to-eye contact. Copyright © 2010 by the Association for Computing Machinery, Inc.

  8. A volumetric flow sensor for automotive injection systems

    Science.gov (United States)

    Schmid, U.; Krötz, G.; Schmitt-Landsiedel, D.

    2008-04-01

    For further optimization of the automotive power train of diesel engines, advanced combustion processes require a highly flexible injection system, provided e.g. by the common rail (CR) injection technique. In the past, the feasibility to implement injection nozzle volumetric flow sensors based on the thermo-resistive measurement principle has been demonstrated up to injection pressures of 135 MPa (1350 bar). To evaluate the transient behaviour of the system-integrated flow sensors as well as an injection amount indicator used as a reference method, hydraulic simulations on the system level are performed for a CR injection system. Experimentally determined injection timings were found to be in good agreement with calculated values, especially for the novel sensing element which is directly implemented into the hydraulic system. For the first time pressure oscillations occurring after termination of the injection pulse, predicted theoretically, could be verified directly in the nozzle. In addition, the injected amount of fuel is monitored with the highest resolution ever reported in the literature.

  9. From Word to Image: Displacement and Meaning in "Greed."

    Science.gov (United States)

    Grindon, Leger

    1989-01-01

    Describes levels of displacement in Stroheim's film "Greed," including (1) the displacement of reason, pleasure, and life by the desire for gold; and (2) the displacement that points to a double movement in Stroheim's cinematic style. Argues that the film's sense of doom arises from the psychic nightmare operating through the mechanics…

  10. 24 CFR 583.310 - Displacement, relocation, and acquisition.

    Science.gov (United States)

    2010-04-01

    ... persons. A displaced person (defined in paragraph (f) of this section) must be provided relocation... “displaced person,” or the amount of relocation assistance for which the person is eligible, may file a... to the HUD field office. (f) Definition of displaced person. (1) For purposes of this section,...

  11. 24 CFR 886.138 - Displacement, relocation, and acquisition.

    Science.gov (United States)

    2010-04-01

    ... regulations at 49 CFR part 24. A “displaced person” shall be advised of his or her rights under the Fair... person is ineligible under 49 CFR 24.2(g)(2); or (iv) HUD determines that the person was not displaced as... persons. A “displaced person” (as defined in paragraph (g) of this section) must be provided...

  12. Temperature insensitive measurements of displacement using fiber Bragg grating sensors

    Science.gov (United States)

    Yang, Shuang; Li, Jun; Xu, Shengming; Sun, Miao; Tang, Yuquan; Gao, Gang; Dong, Fengzhong

    2016-11-01

    Optical fiber Bragg grating (FBG) displacement sensors play an important role in various areas due to the high sensitivity to displacement. However, it becomes a serious problem of FBG cross-sensitivity of temperature and displacement in applications with FBG displacement sensing. This paper presents a method of temperature insensitive measurement of displacement via using an appropriate layout of the sensor. A displacement sensor is constructed with two FBGs mounted on the opposite surface of a cantilever beam. The wavelengths of the FBGs shift with a horizontal direction displacement acting on the cantilever beam. Displacement measurement can be achieved by demodulating the wavelengths difference of the two FBGs. In this case, the difference of the two FBGs' wavelengths can be taken in order to compensate for the temperature effects. Four cantilever beams with different shapes are designed and the FBG strain distribution is quite different from each other. The deformation and strain distribution of cantilever beams are simulated by using finite element analysis, which is used to optimize the layout of the FBG displacement sensor. Experimental results show that an obvious increase in the sensitivity of this change on the displacement is obtained while temperature dependence greatly reduced. A change in the wavelength can be found with the increase of displacement from 0 to 10mm for a cantilever beam. The physical size of the FBG displacement sensor head can be adjusted to meet the need of different applications, such as structure health monitoring, smart material sensing, aerospace, etc.

  13. Rhetorics of Displacement: Constructing Identities in Forced Relocations

    Science.gov (United States)

    Powell, Katrina M.

    2012-01-01

    Forced displacement has often involved the use of rhetoric, both by government institutions and by people who struggle not only to survive displacement, but also to resist it. In this article, the author offers first a theoretical framework that informs her thinking about displacement narratives. She briefly examines two published displacement…

  14. Year of displaced people’s rights in Colombia

    Directory of Open Access Journals (Sweden)

    Marco Alberto Romero

    2007-12-01

    Full Text Available A Campaign for the Rights of Displaced People in Colombia, launched in 2007 by UNHCR, Colombian NGO CODHES and the Catholic Church, has tried to raise awareness in Colombia and the international community about the severity of the country’s displacement crisis and its failure to guarantee the rights of displaced people.

  15. The Theme of Displacement in Contemporary Art

    Directory of Open Access Journals (Sweden)

    John POTTS

    2012-03-01

    Full Text Available Cet article examine les images et idées de dislocation dans des œuvres d'art récentes. Le thème du déplacement ou de la dislocation est traité dans le contexte de l'aspect globalisant de l'art contemporain, considéré lui-même comme un reflet de la mondialisation. Les principaux textes théoriques qui influencent et informent les pratiques en matière de conservation sont abordés, entre autres les écrits de Giorgio Agamben, Nicolas Bourriaud et Rex Butler. Le thème de la dislocation dans l'art contemporain est analysé au travers des œuvres de nombreux artistes, tels que Francis Alÿs, Bill Fontana, Allan Sekula, Chen Chieh-jen, Ai Wei Wei, Rosemary Laing, Mike Parr, Santiago Sierra, Rebecca Belmore et Tracey Moffatt.This essay considers images and ideas of displacement in recent works of art. The theme of displacement is examined in the context of the globalist aspect of contemporary art, itself a reflection of globalisation. Influential theoretical texts informing curatorial practice and the discourse of contemporary art theory are discussed, including the writings of Girogio Agamben, Nicolas Bourriaud and Rex Butler. The theme of displacement in contemporary art is analysed with regard to the work of many artists, including Francis Alÿs, Bill Fontana, Allan Sekula, Chen Chieh-jen, Ai Wei Wei, Rosemary Laing, Mike Parr, Santiago Sierra, Rebecca Belmore and Tracey Moffatt.

  16. Sample displacement chromatography of plasmid DNA isoforms.

    Science.gov (United States)

    Černigoj, Urh; Martinuč, Urška; Cardoso, Sara; Sekirnik, Rok; Krajnc, Nika Lendero; Štrancar, Aleš

    2015-10-02

    Sample displacement chromatography (SDC) is a chromatographic technique that utilises different relative binding affinities of components in a sample mixture and has been widely studied in the context of peptide and protein purification. Here, we report a use of SDC to separate plasmid DNA (pDNA) isoforms under overloading conditions, where supercoiled (sc) isoform acts as a displacer of open circular (oc) or linear isoform. Since displacement is more efficient when mass transfer between stationary and mobile chromatographic phases is not limited by diffusion, we investigated convective interaction media (CIM) monoliths as stationary phases for pDNA isoform separation. CIM monoliths with different hydrophobicities and thus different binding affinities for pDNA (CIM C4 HLD, CIM-histamine and CIM-pyridine) were tested under hydrophobic interaction chromatography (HIC) conditions. SD efficiency for pDNA isoform separation was shown to be dependent on column selectivity for individual isoform, column efficiency and on ammonium sulfate (AS) concentration in loading buffer (binding strength). SD and negative mode elution often operate in parallel, therefore negative mode elution additionally influences the efficiency of the overall purification process. Optimisation of chromatographic conditions achieved 98% sc pDNA homogeneity and a dynamic binding capacity of over 1mg/mL at a relatively low concentration of AS. SDC was successfully implemented for the enrichment of sc pDNA for plasmid vectors of different sizes, and for separation of linear and and sc isoforms, independently of oc:sc isoform ratio, and flow-rate used. This study therefore identifies SDC as a promising new approach to large-scale pDNA purification, which is compatible with continuous, multicolumn chromatography systems, and could therefore be used to increase productivity of pDNA production in the future. Copyright © 2015 Elsevier B.V. All rights reserved.

  17. Rapid Sunspot Displacement Associated with Solar Eruptions

    Science.gov (United States)

    Liu, Chang; Deng, N.; Wang, H.

    2010-05-01

    Many observational and modeling studies of solar eruptions merely treat photosphere as the lower boundary and assume no significant changes of magnetic fields anchoring there to occur during flares/CMEs. With increasing evidence of photospheric magnetic fields variations resulting from energy release in the upper atmosphere, Hudson, Fisher and Welsch (2008, ASP, 383, 221) proposed that the photosphere and even solar interior would respond in a back-reaction process to the coronal magnetic field restructuring. Inspired by this concept, we analyzed white-light images obtained with TRACE and report here rapid and permanent perturbation in the position of delta spot umbrae associated with five X-class flares. Our main results are the following: (1) The centroids of umbrae with opposite magnetic polarities undergo relative as well as overall displacement on the order of 1E3 km after flares/CMEs. (2) The estimated total kinetic energy associated with these motions (Ek) is on the order of 1E29 ergs and appears to correlate with the 6 mHZ seismic energy (Es) derived by the Monash group. (3) There appears correlation between both the Ek and Es corresponding to the velocity of CMEs. We suggest that: (1) sunspot displacement provides a direct observational evidence of the photospheric back-reaction and could potentially serve as an alternative excitation mechanism of seismic waves; (2) These could provide rational support to the back-reaction mechanism in the sense that its magnitude might be related to how violent the coronal magnetic field is disrupted. For selected events with good multiwavelength coverage, we also analyze in detail spatial as well as temporal relationship among the sunspot displacement, magnetic field changes, seismic sources, hard X-ray emissions, and overall flaring condition. This work is supported by NSF grants ATM 08-19662 and ATM 07-45744, and NASA grants NNX 08AQ90G, NNX 07AH78G, and NNX 08AQ32G.

  18. White matter segmentation by estimating tissue optical attenuation from volumetric OCT massive histology of whole rodent brains

    Science.gov (United States)

    Lefebvre, Joël.; Castonguay, Alexandre; Lesage, Frédéric

    2017-02-01

    A whole rodent brain was imaged using an automated massive histology setup and an Optical Coherence Tomography (OCT) microscope. Thousands of OCT volumetric tiles were acquired, each covering a size of about 2.5x2.5x0.8 mm3 with a sampling resolution of 4.9x4.9x6.5 microns. This paper shows the techniques for reconstruction, attenuation compensation and segmentation of the sliced brains. The tile positions within the mosaic were evaluated using a displacement model of the motorized stage and pairwise coregistration. Volume blending was then performed by solving the 3D Laplace equation, and consecutive slices were assembled using the cross-correlation of their 2D image gradient. This reconstruction algorithm resulted in a 3D map of optical reflectivity for the whole brain at micrometric resolution. OCT tissue slices were then used to estimate the local attenuation coefficient based on a single scattering photon model. The attenuation map obtained exhibits a high contrast for all white matter fibres, regardless of their orientation. The tissue optical attenuation from the intrinsic OCT reflectivity contributes to better white matter tissue segmentation. The combined 3D maps of reflectivity and attenuation is a step toward the study of white matter at a microscopic scale for the whole brain in small animals.

  19. Uncovering deformation processes from surface displacements

    Science.gov (United States)

    Stramondo, Salvatore; Trasatti, Elisa; Albano, Matteo; Moro, Marco; Chini, Marco; Bignami, Christian; Polcari, Marco; Saroli, Michele

    2016-12-01

    Today, satellite remote sensing has reached a key role in Earth Sciences. In particular, Synthetic Aperture Radar (SAR) sensors and SAR Interferometry (InSAR) techniques are widely used for the study of dynamic processes occurring inside our living planet. Over the past 3 decades, InSAR has been applied for mapping topography and deformation at the Earth's surface. These maps are widely used in tectonics, seismology, geomorphology, and volcanology, in order to investigate the kinematics and dynamics of crustal faulting, the causes of postseismic and interseismic displacements, the dynamics of gravity driven slope failures, and the deformation associated with subsurface movement of water, hydrocarbons or magmatic fluids.

  20. Galvanic displacement of metals on semiconductor nanocrystals

    Science.gov (United States)

    Johnson, Melanie; Kelly, Joel A.; Henderson, Eric J.; Veinot, Jonathan G. C.

    2009-11-01

    We report the galvanic displacement (GD) of germanium from germanium nanocrystals (Ge-NCs) with silver. The Ge-NCs are synthesized by reductive thermal processing of germanium suboxide sol-gel prepolymers. Thermal processing yields size-controlled oxide-embedded Ge-NCs, which are liberated by dissolution of the germanium oxide matrix in water. Subsequent exposure of the freestanding Ge-NCs to aqueous solutions of AgNO3 leads to deposition of silver nanostructures by GD. The resulting metal structures were analyzed by XRD, XPS, TEM and EDX, confirming deposition of elemental silver in a variety of shapes and sizes.

  1. Galvanic displacement of metals on semiconductor nanocrystals

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, Melanie; Kelly, Joel A; Henderson, Eric J; Veinot, Jonathan G C, E-mail: jveinot@ualberta.ca [University of Alberta, Department of Chemistry, Edmonton, AB, T6G 2G2 (Canada)

    2009-11-15

    We report the galvanic displacement (GD) of germanium from germanium nanocrystals (Ge-NCs) with silver. The Ge-NCs are synthesized by reductive thermal processing of germanium suboxide sol-gel prepolymers. Thermal processing yields size-controlled oxide-embedded Ge-NCs, which are liberated by dissolution of the germanium oxide matrix in water. Subsequent exposure of the freestanding Ge-NCs to aqueous solutions of AgNO{sub 3} leads to deposition of silver nanostructures by GD. The resulting metal structures were analyzed by XRD, XPS, TEM and EDX, confirming deposition of elemental silver in a variety of shapes and sizes.

  2. Simulating People Moving in Displacement Ventilated Rooms

    DEFF Research Database (Denmark)

    Mattsson, M.; Bjørn, Erik; Sandberg, M.

    A displacement ventilation system works better the more uni-directional the air flow through the ventilated room is: from floor to ceiling. Thus, from an air quality point of view, there should be as little vertical mixing of the room air as possible. It is therefore comprehensible that physical...... activity in the room -like peoples movements -in previous studies has been shown to influence the effectiveness of the ventilation. In this study we have compared results from previous tests, where a cylindrical person simulator was used, to results obtained when using a person simulator of more human...

  3. Two-Domain DNA Strand Displacement

    CERN Document Server

    Cardelli, Luca

    2010-01-01

    We investigate the computing power of a restricted class of DNA strand displacement structures: those that are made of double strands with nicks (interruptions) in the top strand. To preserve this structural invariant, we impose restrictions on the single strands they interact with: we consider only two-domain single strands consisting of one toehold domain and one recognition domain. We study fork and join signal-processing gates based on these structures, and we show that these systems are amenable to formalization and to mechanical verification.

  4. Atomic displacement energy in amorphous compounds

    Science.gov (United States)

    Sanditov, D. S.; Mashanov, A. A.

    2016-12-01

    Atomic displacement energy Δɛe in multicomponent sheet and lead-silicate glasses is calculated from the free activation energy of a viscous flow. The value of Δɛe is shown to remain constant in a rather wide range of temperatures in the glass transition region. Satisfactory agreement with calculations of Δɛe using the current formula incorporating the glass transition temperature and the fluctuation volume fraction frozen at this temperature is obtained. The validity of the above formula not only at the glass transition temperature but also in the temperature region adjacent to it is confirmed.

  5. On the Uncertain Future of the Volumetric 3D Display Paradigm

    Science.gov (United States)

    Blundell, Barry G.

    2017-06-01

    Volumetric displays permit electronically processed images to be depicted within a transparent physical volume and enable a range of cues to depth to be inherently associated with image content. Further, images can be viewed directly by multiple simultaneous observers who are able to change vantage positions in a natural way. On the basis of research to date, we assume that the technologies needed to implement useful volumetric displays able to support translucent image formation are available. Consequently, in this paper we review aspects of the volumetric paradigm and identify important issues which have, to date, precluded their successful commercialization. Potentially advantageous characteristics are outlined and demonstrate that significant research is still needed in order to overcome barriers which continue to hamper the effective exploitation of this display modality. Given the recent resurgence of interest in developing commercially viable general purpose volumetric systems, this discussion is of particular relevance.

  6. Volumetric study of the olfactory bulb in patients with chronic rhinonasal sinusitis using MRI

    Directory of Open Access Journals (Sweden)

    Reda A. Alarabawy

    2016-06-01

    Conclusions: MRI with volumetric analysis is a useful tool in assessment of the olfactory bulb volume in patients with olfactory loss and appears to be of help in assessment of the degree of recovery in patients after sinus surgery.

  7. Inkjet printing-based volumetric display projecting multiple full-colour 2D patterns

    Science.gov (United States)

    Hirayama, Ryuji; Suzuki, Tomotaka; Shimobaba, Tomoyoshi; Shiraki, Atsushi; Naruse, Makoto; Nakayama, Hirotaka; Kakue, Takashi; Ito, Tomoyoshi

    2017-04-01

    In this study, a method to construct a full-colour volumetric display is presented using a commercially available inkjet printer. Photoreactive luminescence materials are minutely and automatically printed as the volume elements, and volumetric displays are constructed with high resolution using easy-to-fabricate means that exploit inkjet printing technologies. The results experimentally demonstrate the first prototype of an inkjet printing-based volumetric display composed of multiple layers of transparent films that yield a full-colour three-dimensional (3D) image. Moreover, we propose a design algorithm with 3D structures that provide multiple different 2D full-colour patterns when viewed from different directions and experimentally demonstrate prototypes. It is considered that these types of 3D volumetric structures and their fabrication methods based on widely deployed existing printing technologies can be utilised as novel information display devices and systems, including digital signage, media art, entertainment and security.

  8. Effect of consolidation pressure on volumetric composition and stiffness of unidirectional flax fibre composites

    DEFF Research Database (Denmark)

    Aslan, Mustafa; Mehmood, S.; Madsen, Bo

    2013-01-01

    Unidirectional flax/polyethylene terephthalate composites are manufactured by filament winding, followed by compression moulding with low and high consolidation pressure, and with variable flax fibre content. The experimental data of volumetric composition and tensile stiffness are analysed with ...

  9. Mechanical properties, volumetric shrinkage and depth of cure of short fiber-reinforced resin composite.

    Science.gov (United States)

    Tsujimoto, Akimasa; Barkmeier, Wayne W; Takamizawa, Toshiki; Latta, Mark A; Miyazaki, Masashi

    2016-01-01

    The mechanical properties, volumetric shrinkage and depth of cure of a short fiber-reinforced resin composite (SFRC) were investigated in this study and compared to both a bulk fill resin composite (BFRC) and conventional glass/ceramic-filled resin composite (CGRC). Fracture toughness, flexural properties, volumetric shrinkage and depth of cure of the SFRC, BFRC and CGRC were measured. SFRC had significantly higher fracture toughness than BFRCs and CGRCs. The flexural properties of SFRC were comparable with BFRCs and CGRCs. SFRC showed significantly lower volumetric shrinkage than the other tested resin composites. The depth of cure of the SFRC was similar to BFRCs and higher than CGRCs. The data from this laboratory investigation suggests that SFRC exhibits improvements in fracture toughness, volumetric shrinkage and depth of cure when compared with CGRC, but depth of cure of SFRC was similar to BFRC.

  10. Review of prospects and challenges of eye tracking in volumetric imaging.

    Science.gov (United States)

    Venjakob, Antje C; Mello-Thoms, Claudia R

    2016-01-01

    While eye tracking research in conventional radiography has flourished over the past decades, the number of eye tracking studies that looked at multislice images lags behind. A possible reason for the lack of studies in this area might be that the eye tracking methodology used in the context of conventional radiography cannot be applied one-on-one to volumetric imaging material. Challenges associated with eye tracking in volumetric imaging are particularly associated with the selection of stimulus material, the detection of events in the eye tracking data, the calculation of meaningful eye tracking parameters, and the reporting of abnormalities. However, all of these challenges can be addressed in the design of the experiment. If this is done, eye tracking studies using volumetric imaging material offer almost unlimited opportunity for perception research and are highly relevant as the number of volumetric images that are acquired and interpreted is rising.

  11. Grating Loaded Cantilevers for Displacement Measurements

    Science.gov (United States)

    Karademir, Ertugrul; Olcum, Selim; Atalar, Abdullah; Aydinli, Atilla

    2010-03-01

    A cantilever with a grating coupler engraved on its tip is used for measuring displacement. The coupled light in the cantilever is guided to a single mode optical waveguide defined at the base of the cantilever. The grating period is 550 nm and is fabricated on a SOI wafer using nanoimprint lithography. The waveguide and the cantilever are defined by an RIE and cantilevers released by KOH and HF solutions. Light with 1550 nm wavelength, is directed onto the grating coupler and detected at the cleaved end of the SOI waveguide. The angle of incidence is controlled by a motorized rotary stage. Light couples into the waveguide at a characteristic angle with a full width at half maximum of approximately 6.9 mrads translating into a Q factor of 87.5. The displacement sensitivity is measured by driving the cantilever with a frequency controlled piezoelectric element. The modulation of the light at the waveguide output is lock-in detected by a biased infrared detector. The resulting 43%mrad-1 sensitivity can be increased with further optimization.

  12. Precision optical displacement measurements using biphotons

    Science.gov (United States)

    Lyons, Kevin; Pang, Shengshi; Kwiat, Paul G.; Jordan, Andrew N.

    2016-04-01

    We propose and examine the use of biphoton pairs, such as those created in parametric down-conversion or four-wave mixing, to enhance the precision and the resolution of measuring optical displacements by position-sensitive detection. We show that the precision of measuring a small optical beam displacement with this method can be significantly enhanced by the correlation between the two photons, given the same optical mode. The improvement is largest if the correlations between the photons are strong, and falls off as the biphoton correlation weakens. More surprisingly, we find that the smallest resolvable parameter of a simple split detector scales as the inverse of the number of biphotons for small biphoton number ("Heisenberg scaling"), because the Fisher information diverges as the parameter to be estimated decreases in value. One usually sees this scaling only for systems with many entangled degrees of freedom. We discuss the transition for the split-detection scheme to the standard quantum limit scaling for imperfect correlations as the biphoton number is increased. An analysis of an N -pixel detector is also given to investigate the benefit of using a higher resolution detector. The physical limit of these metrology schemes is determined by the uncertainty in the birth zone of the biphoton in the nonlinear crystal.

  13. Displacing lateral meniscus masquerading as patella dislocation.

    Science.gov (United States)

    Arendt, Elizabeth A; Fontboté, Cristián A; Rohr, Sara R

    2014-10-01

    To alert the treating clinician to an uncommon knee meniscal condition that often masquerades as a more common patella condition. Retrospective chart review of a series of cases was undertaken. A series of 12 knees in 11 patients were referred to an orthopaedic surgeon with a diagnosis of recurrent lateral patella dislocation. Three knees had undergone patella realignment surgery with continuance of symptoms. Eight patients had prior magnetic resonance images read as no meniscal pathology and no acute patella/patella retinacular injury. All patients presented for a consult with a similar history. Under anaesthesia, all knees had a stable patella as judged by physical examination. At the time of surgery, six patients had a frank tear in the lateral meniscus, all of which were readily displaceable. Six knees showed a displaceable lateral meniscus with attenuation but not a visible frank tear. Ten menisci were treated with repair, and two knees underwent partial lateral meniscectomies. Patient follow-up of minimally 18 months revealed no further episodes of "knee-cap dislocation" or symptoms of catching and locking. The clinician treating a patient with a history of a knee locking in flexion should have a high index of suspicion for a lateral meniscus tear or an unstable hypermobile lateral meniscus, despite patient report of perceived patella movement. History of symptoms occurring in knee flexion and attention to patella physical examination should be key factors in this diagnostic conundrum. Retrospective chart review, Level IV.

  14. Estimating Hydrologic Processes from Subsurface Soil Displacements

    Science.gov (United States)

    Freeman, C. E.; Murdoch, L. C.; Germanovich, L.; MIller, S.

    2012-12-01

    Soil moisture and the processes that control it are important components of the hydrologic cycle, but measuring these processes remains challenging. We have developed a new measurement method that offers flexibility compared to existing technology. The approach is to measure small vertical displacements in the soil which responds proportionally to distributed surface load changes such as variation in the near-surface water content. The instrument may be installed at a depth of several meters to hundreds of meters below the surface. Because the measurement averaging region scales with the depth of the displacement measurements, this approach provides the means for estimating the soil moisture time series over tens of square meters to tens of thousands of square meters. The instrument developed for this application is called a Sand-X, which is short for Sand Extensometer. It is designed for applications in unconsolidated material, ranging from clay to sand. The instrument is simple and relatively inexpensive, and it can be installed in a boring made with a hand auger or with a small drill rig. Studies at the field scale are ongoing at a field site near Clemson, SC. The site is underlain by saprolite weathered primarily from biotite gneiss. Several Sand-X devices are installed at a field site that is instrumented for validating soil moisture, precipitation, and evapotranspiration estimates. These instruments are emplaced at a depth of 6 m and respond to the weight of a vehicle out to 18 m from the well. Calibration is performed by comparing precipitation measurements to the soil displacement response. For example, the coefficient for one installation is roughly 185 nm soil displacement/mm water content change. The resolution of the instrument is approximately 10 nm, so the Sand-X is capable of detecting changes of soil moisture on the order of tenths of one mm in compliant soils like saprolite. A typical soil displacement time series shows alternating periods of

  15. Attenuation of Scalar Fluxes Measured with Spatially-displaced Sensors

    Science.gov (United States)

    Horst, T. W.; Lenschow, D. H.

    2009-02-01

    Observations from the Horizontal Array Turbulence Study (HATS) field program are used to examine the attenuation of measured scalar fluxes caused by spatial separation between the vertical velocity and scalar sensors. The HATS data show that flux attenuation for streamwise, crosswind, and vertical sensor displacements are each a function of a dimensionless, stability-dependent parameter n m multiplied by the ratio of sensor displacement to measurement height. The scalar flux decays more rapidly with crosswind displacements than for streamwise displacements and decays more rapidly for stable stratification than for unstable stratification. The cospectral flux attenuation model of Kristensen et al. agrees well with the HATS data for streamwise sensor displacements, although it is necessary to include a neglected quadrature spectrum term to explain the observation that flux attenuation is often less with the scalar sensor downwind of the anemometer than for the opposite configuration. A simpler exponential decay model provides good estimates for crosswind sensor displacements, as well as for streamwise sensor displacements with stable stratification. A model similar to that of Lee and Black correctly predicts flux attenuation for a combination of streamwise and crosswind displacements, i.e. as a function of wind direction relative to the sensor displacement. The HATS data for vertical sensor displacements extend the near-neutral results of Kristensen et al. to diabatic stratification and confirm their finding that flux attenuation is less with the scalar sensor located below the anemometer than if the scalar sensor is displaced an equal distance either horizontally or above the anemometer.

  16. Volumetric Properties of the Mixture Tetrachloromethane CCl4 + CHCl3 Trichloromethane (VMSD1212, LB4576_V)

    Science.gov (United States)

    Cibulka, I.; Fontaine, J.-C.; Sosnkowska-Kehiaian, K.; Kehiaian, H. V.

    This document is part of Subvolume C 'Binary Liquid Systems of Nonelectrolytes III' of Volume 26 'Heats of Mixing, Vapor-Liquid Equilibrium, and Volumetric Properties of Mixtures and Solutions' of Landolt-Börnstein Group IV 'Physical Chemistry'. It contains the Chapter 'Volumetric Properties of the Mixture Tetrachloromethane CCl4 + CHCl3 Trichloromethane (VMSD1212, LB4576_V)' providing data by calculation of molar excess volume from low-pressure density measurements at variable mole fraction and constant temperature.

  17. Determination of ferrous iron in rock and mineral samples by three volumetric methods

    OpenAIRE

    Saikkonen, R.J.; Rautiainen, I.A.

    1993-01-01

    Ferrous iron was determined by three volumetric methods in 13 in-house reference rock samples and in 31 international geological reference samples. The methods used were Amonette & Scott' s oxidimetric method, Wilson's oxidimetric method and Pratt's method. The results for FeO by these volumetric methods in 13 in-house rock samples were compared to the results obtained in other analytical laboratories in Finland. The results for FeO in the international samples were compared with published da...

  18. FEMUR SHAPE RECOVERY FROM VOLUMETRIC IMAGES USING 3-D DEFORMABLE MODELS

    Institute of Scientific and Technical Information of China (English)

    2000-01-01

    A new scheme for femur shape recovery from volumetric images using deformable models was proposed. First, prior 3-D deformable femur models are created as templates using point distribution models technology. Second, active contour models are employed to segment the magnetic resonance imaging (MRI) volumetric images of the tibial and femoral joints and the deformable models are initialized based on the segmentation results. Finally, the objective function is minimized to give the optimal results constraining the surface of shapes.

  19. Understanding Volumetric and Gravimetric Hydrogen Adsorption Trade-off in Metal-Organic Frameworks.

    Science.gov (United States)

    Gómez-Gualdrón, Diego A; Wang, Timothy C; García-Holley, Paula; Sawelewa, Ruth M; Argueta, Edwin; Snurr, Randall Q; Hupp, Joseph T; Yildirim, Taner; Farha, Omar K

    2017-04-07

    Metal-organic frameworks (MOFs) are porous crystalline materials that are promising for adsorption-based, on-board storage of hydrogen in fuel-cell vehicles. Volumetric and gravimetric hydrogen capacities are the key factors that determine the size and weight of the MOF-filled tank required to store a certain amount of hydrogen for reasonable driving range. Therefore, they must be optimized so the tank is neither too large nor too heavy. Because the goals of maximizing MOF volumetric and gravimetric hydrogen adsorption loadings individually are incompatible, an in-depth understanding of the trade-off between MOF volumetric and gravimetric loadings is necessary to achieve the best compromise between these properties. Here we study, both experimentally and computationally, the trade-off between volumetric and gravimetric cryo-adsorbed hydrogen deliverable capacity by taking an isoreticular series of highly stable zirconium MOFs, NU-1101, NU-1102, and NU-1103 as a case study. These MOFs were studied under recently proposed operating conditions: 77 K/100 bar →160 K/5 bar. We found the difference between highest and lowest measured deliverable capacity in the MOF series to be ca. 40% gravimetrically, but only ca. 10% volumetrically. From our molecular simulation results, we found hydrogen "monolayer" adsorption to be proportional to the surface area, whereas hydrogen "pore filling" adsorption is proportional to the pore volume. Thus, we found that the higher variability in gravimetric deliverable capacity in contrast to the volumetric capacity, occurs due to the proportional relation between gravimetric surface area and pore volume in the NU-110x series in contrast to the inverse relation between volumetric surface area and void fraction. Additionally, we find better correlations with geometric surface areas than with BET areas. NU-1101 presents the highest measured volumetric performance with 46.6 g/L (9.1 wt %), whereas NU-1103 presents the highest gravimetric one

  20. The effect of base pair mismatch on DNA strand displacement

    CERN Document Server

    Broadwater, Bo

    2016-01-01

    DNA strand displacement is a key reaction in DNA homologous recombination and DNA mismatch repair and is also heavily utilized in DNA-based computation and locomotion. Despite its ubiquity in science and engineering, sequence-dependent effects of displacement kinetics have not been extensively characterized. Here, we measured toehold-mediated strand displacement kinetics using single-molecule fluorescence in the presence of a single base pair mismatch. The apparent displacement rate varied significantly when the mismatch was introduced in the invading DNA strand. The rate generally decreased as the mismatch in the invader was encountered earlier in displacement. Our data indicate that a single base pair mismatch in the invader stalls branch migration, and displacement occurs via direct dissociation of the destabilized incumbent strand from the substrate strand. We combined both branch migration and direct dissociation into a model, which we term, the concurrent displacement model, and used the first passage t...

  1. Optimization of volumetric breast density estimation in digital mammograms.

    Science.gov (United States)

    Holland, Katharina; Gubern-Mérida, Albert; Mann, Ritse M; Karssemeijer, Nico

    2017-05-07

    Fibroglandular tissue volume and percent density can be estimated in unprocessed mammograms using a physics-based method, which relies on an internal reference value representing the projection of fat only. However, pixels representing fat only may not be present in dense breasts, causing an underestimation of density measurements. In this work, we investigate alternative approaches for obtaining a tissue reference value to improve density estimations, particularly in dense breasts. Two of three investigated reference values (F1, F2) are percentiles of the pixel value distribution in the breast interior (the contact area of breast and compression paddle). F1 is determined in a small breast interior, which minimizes the risk that peripheral pixels are included in the measurement at the cost of increasing the chance that no proper reference can be found. F2 is obtained using a larger breast interior. The new approach which is developed for very dense breasts does not require the presence of a fatty tissue region. As reference region we select the densest region in the mammogram and assume that this represents a projection of entirely dense tissue embedded between the subcutaneous fatty tissue layers. By measuring the thickness of the fat layers a reference (F3) can be computed. To obtain accurate breast density estimates irrespective of breast composition we investigated a combination of the results of the three reference values. We collected 202 pairs of MRI's and digital mammograms from 119 women. We compared the percent dense volume estimates based on both modalities and calculated Pearson's correlation coefficients. With the references F1-F3 we found respectively a correlation of [Formula: see text], [Formula: see text] and [Formula: see text]. Best results were obtained with the combination of the density estimations ([Formula: see text]). Results show that better volumetric density estimates can be obtained with the hybrid method, in particular for dense

  2. Semiautomatic segmentation of liver metastases on volumetric CT images

    Energy Technology Data Exchange (ETDEWEB)

    Yan, Jiayong [Department of Biomedical Engineering, Shanghai University of Medicine & Health Sciences, 101 Yingkou Road, Yang Pu District, Shanghai 200093 (China); Schwartz, Lawrence H.; Zhao, Binsheng, E-mail: bz2166@cumc.columbia.edu [Department of Radiology, Columbia University Medical Center, 630 West 168th Street, New York, New York 10032 (United States)

    2015-11-15

    Purpose: Accurate segmentation and quantification of liver metastases on CT images are critical to surgery/radiation treatment planning and therapy response assessment. To date, there are no reliable methods to perform such segmentation automatically. In this work, the authors present a method for semiautomatic delineation of liver metastases on contrast-enhanced volumetric CT images. Methods: The first step is to manually place a seed region-of-interest (ROI) in the lesion on an image. This ROI will (1) serve as an internal marker and (2) assist in automatically identifying an external marker. With these two markers, lesion contour on the image can be accurately delineated using traditional watershed transformation. Density information will then be extracted from the segmented 2D lesion and help determine the 3D connected object that is a candidate of the lesion volume. The authors have developed a robust strategy to automatically determine internal and external markers for marker-controlled watershed segmentation. By manually placing a seed region-of-interest in the lesion to be delineated on a reference image, the method can automatically determine dual threshold values to approximately separate the lesion from its surrounding structures and refine the thresholds from the segmented lesion for the accurate segmentation of the lesion volume. This method was applied to 69 liver metastases (1.1–10.3 cm in diameter) from a total of 15 patients. An independent radiologist manually delineated all lesions and the resultant lesion volumes served as the “gold standard” for validation of the method’s accuracy. Results: The algorithm received a median overlap, overestimation ratio, and underestimation ratio of 82.3%, 6.0%, and 11.5%, respectively, and a median average boundary distance of 1.2 mm. Conclusions: Preliminary results have shown that volumes of liver metastases on contrast-enhanced CT images can be accurately estimated by a semiautomatic segmentation

  3. Blockwise conjugate gradient methods for image reconstruction in volumetric CT.

    Science.gov (United States)

    Qiu, W; Titley-Peloquin, D; Soleimani, M

    2012-11-01

    Cone beam computed tomography (CBCT) enables volumetric image reconstruction from 2D projection data and plays an important role in image guided radiation therapy (IGRT). Filtered back projection is still the most frequently used algorithm in applications. The algorithm discretizes the scanning process (forward projection) into a system of linear equations, which must then be solved to recover images from measured projection data. The conjugate gradients (CG) algorithm and its variants can be used to solve (possibly regularized) linear systems of equations Ax=b and linear least squares problems minx∥b-Ax∥2, especially when the matrix A is very large and sparse. Their applications can be found in a general CT context, but in tomography problems (e.g. CBCT reconstruction) they have not widely been used. Hence, CBCT reconstruction using the CG-type algorithm LSQR was implemented and studied in this paper. In CBCT reconstruction, the main computational challenge is that the matrix A usually is very large, and storing it in full requires an amount of memory well beyond the reach of commodity computers. Because of these memory capacity constraints, only a small fraction of the weighting matrix A is typically used, leading to a poor reconstruction. In this paper, to overcome this difficulty, the matrix A is partitioned and stored blockwise, and blockwise matrix-vector multiplications are implemented within LSQR. This implementation allows us to use the full weighting matrix A for CBCT reconstruction without further enhancing computer standards. Tikhonov regularization can also be implemented in this fashion, and can produce significant improvement in the reconstructed images.

  4. Application of AAPM TG 119 to volumetric arc therapy (VMAT).

    Science.gov (United States)

    Mynampati, Dinesh Kumar; Yaparpalvi, Ravindra; Hong, Linda; Kuo, Hsiang-Chi; Mah, Dennis

    2012-09-06

    The purpose of this study was to create AAPM TG 119 benchmark plans for volumetric arc therapy (VMAT) and to compare VMAT plans with IMRT plan data. AAPM TG 119 proposes a set of test clinical cases for testing the accuracy of IMRT planning and delivery system. For these test cases, we generated two treatment plans, the first plan using 7-9 static dMLC IMRT fields and a second plan utilizing one- or two-arc VMAT technique. Dose optimization and calculations performed using 6 MV photons and Eclipse treatment planning system. Dose prescription and planning objectives were set according to the TG 119 goals. Plans were scored based on TG 119 planning objectives. Treatment plans were compared using conformity index (CI) for reference dose and homogeneity index (HI) (for D(5)-D(95)). For test cases prostate, head-and-neck, C-shape and multitarget prescription dose are 75.6 Gy, 50.4 Gy, 50 Gy and 50 Gy, respectively. VMAT dose distributions were comparable to dMLC IMRT plans. Our planning results matched TG 119 planning results. For treatment plans studied, conformity indices ranged from 1.05-1.23 (IMRT) and 1.04-1.23 (VMAT). Homogeneity indices ranged from 4.6%-11.0% (IMRT) and 4.6%-10.5% (VMAT). The ratio of total monitor units necessary for dMLC IMRT to that of VMAT was in the range of 1.1-2.0. AAPM TG 119 test cases are useful to generate VMAT benchmark plans. At preclinical implementation stage, plan comparison of VMAT and IMRT plans of AAPM TG 119 test case allowed us to understand basic capabilities of VMAT technique.

  5. Mammographic density estimation with automated volumetric breast density measurement.

    Science.gov (United States)

    Ko, Su Yeon; Kim, Eun-Kyung; Kim, Min Jung; Moon, Hee Jung

    2014-01-01

    To compare automated volumetric breast density measurement (VBDM) with radiologists' evaluations based on the Breast Imaging Reporting and Data System (BI-RADS), and to identify the factors associated with technical failure of VBDM. In this study, 1129 women aged 19-82 years who underwent mammography from December 2011 to January 2012 were included. Breast density evaluations by radiologists based on BI-RADS and by VBDM (Volpara Version 1.5.1) were compared. The agreement in interpreting breast density between radiologists and VBDM was determined based on four density grades (D1, D2, D3, and D4) and a binary classification of fatty (D1-2) vs. dense (D3-4) breast using kappa statistics. The association between technical failure of VBDM and patient age, total breast volume, fibroglandular tissue volume, history of partial mastectomy, the frequency of mass > 3 cm, and breast density was analyzed. The agreement between breast density evaluations by radiologists and VBDM was fair (k value = 0.26) when the four density grades (D1/D2/D3/D4) were used and moderate (k value = 0.47) for the binary classification (D1-2/D3-4). Twenty-seven women (2.4%) showed failure of VBDM. Small total breast volume, history of partial mastectomy, and high breast density were significantly associated with technical failure of VBDM (p = 0.001 to 0.015). There is fair or moderate agreement in breast density evaluation between radiologists and VBDM. Technical failure of VBDM may be related to small total breast volume, a history of partial mastectomy, and high breast density.

  6. Comparison Of The Powers Of Energy Losses In A Variable Capacity Displacement Pump Determined Without Or With Taking Into Account The Power Of Hydraulic Oil Compression

    Directory of Open Access Journals (Sweden)

    Paszota Zygmunt

    2015-04-01

    Full Text Available Powers of energy losses in a variable capacity displacement pump are compared with or without taking into account the power of hydraulic oil compression. Evaluation of power of liquid compression in the pump was made possible by the use of method, proposed by the Author, of determining the degree of liquid aeration in the pump. In the method of determining the liquid aeration in the pump and of powers of volumetric losses of liquid compression a simplified formula (qPvc × ΔpPi/2 was used describing the field of indicated work of volumetric losses qPvc of liquid compression during one shaft revolution at indicated increase ΔpPi of pressure in the chambers. Three methods were used for comparing the sum of powers of volumetric losses ΔPPvl due to leakage and ΔPPvc of compression and also ΔPPm|ΔpPi of mechanical losses resulting from increase ΔpPi of indicated pressure in the working chambers.

  7. An Alternative to Maxwell's Displacement Current

    CERN Document Server

    Wolsky, Alan M

    2014-01-01

    Though sufficient for local conservation of charge, we show that Maxwells displacement current is not necessary. An alternative to the Ampere Maxwell equation is exhibited and the alternative s electric and magnetic fields and scalar and vector potentials are expressed in terms of the charge and current densities. The alternative describes a theory in which action is instantaneous and so may provide a good approximation to Maxwells equations where and when the finite speed of light can be neglected. The result is reminiscent of the Darwin approximation which arose from the study classical charged point particles to order (v/c)2 in the Lagrangian. Unlike Darwin, this approach does not depend on the constitution of the electric current. Instead, this approach grows from a straightforward revision of the Ampere Equation which revision enforces the local conservation of charge.

  8. Analog Computation by DNA Strand Displacement Circuits.

    Science.gov (United States)

    Song, Tianqi; Garg, Sudhanshu; Mokhtar, Reem; Bui, Hieu; Reif, John

    2016-08-19

    DNA circuits have been widely used to develop biological computing devices because of their high programmability and versatility. Here, we propose an architecture for the systematic construction of DNA circuits for analog computation based on DNA strand displacement. The elementary gates in our architecture include addition, subtraction, and multiplication gates. The input and output of these gates are analog, which means that they are directly represented by the concentrations of the input and output DNA strands, respectively, without requiring a threshold for converting to Boolean signals. We provide detailed domain designs and kinetic simulations of the gates to demonstrate their expected performance. On the basis of these gates, we describe how DNA circuits to compute polynomial functions of inputs can be built. Using Taylor Series and Newton Iteration methods, functions beyond the scope of polynomials can also be computed by DNA circuits built upon our architecture.

  9. Displaced fracture through the anterior atlantal synchondrosis

    Energy Technology Data Exchange (ETDEWEB)

    Thakar, Chrishan; Allibone, James [Royal National Orthopaedic Hospital NHS Trust, Department of Spinal Deformity, Stanmore, Middlesex (United Kingdom); Harish, Srinivasan [Royal National Orthopaedic Hospital NHS Trust, Department of Radiology, Stanmore, Middlesex (United Kingdom); Saifuddin, Asif [Royal National Orthopaedic Hospital NHS Trust, Department of Radiology, Stanmore, Middlesex (United Kingdom); University College, The Institute of Orthopaedics and Musculoskeletal Sciences, London (United Kingdom)

    2005-09-01

    In the acute setting, accurate radiological interpretation of paediatric cervical spine trauma can be difficult due to a combination of normal variants and presence of multiple synchondroses. We present a rare case of a fracture through the anterior atlantal synchondrosis in a paediatric spine. A five-year-old boy, who fell backwards onto the top of his head while swinging across on a monkey bar frame, presented with neck pain, cervical muscle spasm and decreased right lateral rotation and extension of his neck. Computed tomography showed a displaced diastatic fracture through right anterior atlantal synchondrosis. There are only 12 cases of paediatric C1 fractures reported in the world literature. The importance of considering this diagnosis in the appropriate clinical setting, and the normal variants in the paediatric atlas that can cause diagnostic dilemma to the interpreting radiologist, are discussed in this case report. (orig.)

  10. Superconducting inductive displacement detection of a microcantilever

    Energy Technology Data Exchange (ETDEWEB)

    Vinante, A., E-mail: anvinante@fbk.eu [Istituto di Fotonica e Nanotecnologie, CNR - Fondazione Bruno Kessler, I-38123 Povo, Trento (Italy)

    2014-07-21

    We demonstrate a superconducting inductive technique to measure the displacement of a micromechanical resonator. In our scheme, a type I superconducting microsphere is attached to the free end of a microcantilever and approached to the loop of a dc Superconducting Quantum Interference Device (SQUID) microsusceptometer. A local magnetic field as low as 100 μT, generated by a field coil concentric to the SQUID, enables detection of the cantilever thermomechanical noise at 4.2 K. The magnetomechanical coupling and the magnetic spring are in good agreement with image method calculations assuming pure Meissner effect. These measurements are relevant to recent proposals of quantum magnetomechanics experiments based on levitating superconducting microparticles.

  11. DNA strand displacement system running logic programs.

    Science.gov (United States)

    Rodríguez-Patón, Alfonso; Sainz de Murieta, Iñaki; Sosík, Petr

    2014-01-01

    The paper presents a DNA-based computing model which is enzyme-free and autonomous, not requiring a human intervention during the computation. The model is able to perform iterated resolution steps with logical formulae in conjunctive normal form. The implementation is based on the technique of DNA strand displacement, with each clause encoded in a separate DNA molecule. Propositions are encoded assigning a strand to each proposition p, and its complementary strand to the proposition ¬p; clauses are encoded comprising different propositions in the same strand. The model allows to run logic programs composed of Horn clauses by cascading resolution steps. The potential of the model is demonstrated also by its theoretical capability of solving SAT. The resulting SAT algorithm has a linear time complexity in the number of resolution steps, whereas its spatial complexity is exponential in the number of variables of the formula. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  12. Axial flow positive displacement worm compressor

    Science.gov (United States)

    Murrow, Kurt David (Inventor); Giffin, Rollin George (Inventor); Fakunle, Oladapo (Inventor)

    2010-01-01

    An axial flow positive displacement compressor has an inlet axially spaced apart and upstream from an outlet. Inner and outer bodies have offset inner and outer axes extend from the inlet to the outlet through first and second sections of a compressor assembly in serial downstream flow relationship. At least one of the bodies is rotatable about its axis. The inner and outer bodies have intermeshed inner and outer helical blades wound about the inner and outer axes respectively. The inner and outer helical blades extend radially outwardly and inwardly respectively. The helical blades have first and second twist slopes in the first and second sections respectively. The first twist slopes are less than the second twist slopes. An engine including the compressor has in downstream serial flow relationship from the compressor a combustor and a high pressure turbine drivingly connected to the compressor by a high pressure shaft.

  13. Axial flow positive displacement worm gas generator

    Science.gov (United States)

    Murrow, Kurt David (Inventor); Giffin, Rollin George (Inventor); Fakunle, Oladapo (Inventor)

    2010-01-01

    An axial flow positive displacement engine has an inlet axially spaced apart and upstream from an outlet. Inner and outer bodies have offset inner and outer axes extend from the inlet to the outlet through first, second, and third sections of a core assembly in serial downstream flow relationship. At least one of the bodies is rotatable about its axis. The inner and outer bodies have intermeshed inner and outer helical blades wound about the inner and outer axes respectively. The inner and outer helical blades extend radially outwardly and inwardly respectively. The helical blades have first, second, and third twist slopes in the first, second, and third sections respectively. The first twist slopes are less than the second twist slopes and the third twist slopes are less than the second twist slopes. A combustor section extends axially downstream through at least a portion of the second section.

  14. DNA Strand-Displacement Timer Circuits.

    Science.gov (United States)

    Fern, Joshua; Scalise, Dominic; Cangialosi, Angelo; Howie, Dylan; Potters, Leo; Schulman, Rebecca

    2017-02-17

    Chemical circuits can coordinate elaborate sequences of events in cells and tissues, from the self-assembly of biological complexes to the sequence of embryonic development. However, autonomously directing the timing of events in synthetic systems using chemical signals remains challenging. Here we demonstrate that a simple synthetic DNA strand-displacement circuit can release target sequences of DNA into solution at a constant rate after a tunable delay that can range from hours to days. The rates of DNA release can be tuned to the order of 1-100 nM per day. Multiple timer circuits can release different DNA strands at different rates and times in the same solution. This circuit can thus facilitate precise coordination of chemical events in vitro without external stimulation.

  15. Can Monkeys (Macaca mulatta) Represent Invisible Displacement?

    Science.gov (United States)

    Filion, Christine M.; Washburn, David A.; Gulledge, Jonathan P.

    1996-01-01

    Four experiments were conducted to assess whether or not rhesus macaques (Macaca mulatta) could represent the unperceived movements of a stimulus. Subjects were tested on 2 computerized tasks, HOLE (monkeys) and LASER (humans and monkeys), in which subjects needed to chase or shoot at, respectively, a moving target that either remained visible or became invisible for a portion of its path of movement. Response patterns were analyzed and compared between target-visible and target-invisible conditions. Results of Experiments 1, 2, and 3 demonstrated that the monkeys are capable of extrapolating movement. That this extrapolation involved internal representation of the target's invisible movement was suggested but not confirmed. Experiment 4, however, demonstrated that the monkeys are capable of representing the invisible displacements of a stimulus.

  16. Dynamics of liquid-liquid displacement.

    Science.gov (United States)

    Fetzer, Renate; Ramiasa, Melanie; Ralston, John

    2009-07-21

    Capillary driven liquid-liquid displacement in a system with two immiscible liquids of comparable viscosity was investigated by means of optical high speed video microscopy. For the first time, the impact of substrate wettability on contact line dynamics in liquid-liquid systems was studied. On all substrates, qualitatively different dynamics, in two distinct velocity regimes, were found. Hydrodynamic models apply to the fast stage of initial spreading, while nonhydrodynamic dissipation dominates contact line motion in a final stage at low speed, where the molecular kinetic theory (MKT) successfully captured the dynamics. The MKT model parameter values showed no systematic dependence on substrate wettability. This unexpected result is interpreted in terms of local contact line pinning.

  17. Anisotropic permeability in deterministic lateral displacement arrays

    CERN Document Server

    Vernekar, Rohan; Loutherback, Kevin; Morton, Keith; Inglis, David

    2016-01-01

    We investigate anisotropic permeability of microfluidic deterministic lateral displacement (DLD) arrays. A DLD array can achieve high-resolution bimodal size-based separation of micro-particles, including bioparticles such as cells. Correct operation requires that the fluid flow remains at a fixed angle with respect to the periodic obstacle array. We show via experiments and lattice-Boltzmann simulations that subtle array design features cause anisotropic permeability. The anisotropy, which indicates the array's intrinsic tendency to induce an undesired lateral pressure gradient, can lead to off-axis flows and therefore local changes in the critical separation size. Thus, particle trajectories can become unpredictable and the device useless for the desired separation duty. We show that for circular posts the rotated-square layout, unlike the parallelogram layout, does not suffer from anisotropy and is the preferred geometry. Furthermore, anisotropy becomes severe for arrays with unequal axial and lateral gaps...

  18. Has multivessel angioplasty displaced surgical revascularization?

    Science.gov (United States)

    King, S B; Ivanhoe, R J

    1990-01-01

    Over the years, PTCA has been proved a safe and effective therapy for single-vessel CAD. Given the record of favorable results for single-vessel angioplasty, the extension of angioplasty to multivessel CAD soon followed. The successful application of PTCA to multivessel disease has been facilitated by developments in balloon, guidewire, and guide catheter technology. Success rates have been satisfactory, and complications have remained acceptable. Furthermore, as an outgrowth of an understanding of the mechanism and effect of PTCA, guidelines have been developed to aid case selection. As emphasized earlier, these guidelines should weigh heavily in deciding whether to select PTCA as a treatment modality. Presently, in our opinion, PTCA has not yet completely displaced surgery for multivessel CAD. Surgical standby is required for safe PTCA, because emergency surgery can be lifesaving and limit myocardial infarction after failed angioplasty. It is doubtful that surgery will ever relinquish its position as the treatment of choice for left main coronary artery disease. Nor will elective surgery find wide application in single-vessel disease. Whether one mode of revascularization will emerge as the most efficacious for multivessel disease related to long-term survival, limitation of cardiac events, and cost will be addressed in the analysis of the ongoing randomized trials of surgery versus angioplasty. Andreas Gruentzig established that it was possible to work within the coronary artery in an alert and comfortable patient. Interventional cardiology has experienced rapid technologic growth. Many patients formerly treated with bypass surgery can be managed effectively with angioplasty. If effective bail-out methods for acute closure are proven effective and restenosis is limited to a small percentage of patients, angioplasty in some form will further displace CABG. Until those ultimate goals are achieved, the value of angioplasty compared with bypass surgery must rest

  19. Fluid trapping during capillary displacement in fractures

    Science.gov (United States)

    Yang, Zhibing; Neuweiler, Insa; Méheust, Yves; Fagerlund, Fritjof; Niemi, Auli

    2016-09-01

    The spatial distribution of fluid phases and the geometry of fluid-fluid interfaces resulting from immiscible displacement in fractures cast decisive influence on a range of macroscopic flow parameters. Most importantly, these are the relative permeabilities of the fluids as well as the macroscopic irreducible saturations. They also influence parameters for component (solute) transport, as it usually occurs through one of the fluid phase only. Here, we present a numerical investigation on the critical role of aperture variation and spatial correlation on fluid trapping and the morphology of fluid phase distributions in a geological fracture. We consider drainage in the capillary dominated regime. The correlation scale, that is, the scale over which the two facing fracture walls are matched, varies among the investigated geometries between L/256 and L (self-affine fields), L being the domain/fracture length. The aperture variability is quantified by the coefficient of variation (δ), ranging among the various geometries from 0.05 to 0.25. We use an invasion percolation based model which has been shown to properly reproduce displacement patterns observed in previous experiments. We present a quantitative analysis of the size distribution of trapped fluid clusters. We show that when the in-plane curvature is considered, the amount of trapped fluid mass first increases with increasing correlation scale Lc and then decreases as Lc further increases from some intermediate scale towards the domain length scale L. The in-plane curvature contributes to smoothening the invasion front and to dampening the entrapment of fluid clusters of a certain size range that depends on the combination of random aperture standard deviation and spatial correlation.

  20. Systematic review of mini-implant displacement under orthodontic loading

    Institute of Scientific and Technical Information of China (English)

    Manuel Nienkemper; Jörg Handschel; Dieter Drescher

    2014-01-01

    A growing number of studies have reported that mini-implants do not remain in exactly the same position during treatment, although they remain stable. The aim of this review was to collect data regarding primary displacement immediately straight after loading and secondary displacement over time. A systematic review was performed to investigate primary and secondary displacement. The amount and type of displacement were recorded. A total of 27 studies were included. Sixteen in vitro studies or studies using finite element analysis addressed primary displacement, and nine clinical studies and two animal studies addressed secondary displacement. Significant primary displacement was detected (6.4-24.4 mm) for relevant orthodontic forces (0.5-2.5 N). The mean secondary displacement ranged from 0 to 2.7 mm for entire mini-implants. The maximum values for each clinical study ranged from 1.0 to 4.1 mm for the head, 1.0 to 1.5 for the body and 1.0 to 1.92 mm for the tail part. The most frequent type of movement was controlled tipping or bodily movement. Primary displacement did not reach a clinically significant level. However, clinicians can expect relevant secondary displacement in the direction of force. Consequently, decentralized insertion within the inter-radicular space, away from force direction, might be favourable. More evidence is needed to provide quantitative recommendations.

  1. A Technique for Generating Volumetric Cine MRI (VC-MRI)

    Science.gov (United States)

    Harris, Wendy; Ren, Lei; Cai, Jing; Zhang, You; Chang, Zheng; Yin, Fang-Fang

    2016-01-01

    Purpose To develop a technique to generate on-board volumetric-cine MRI (VC-MRI) using patient prior images, motion modeling and on-board 2D-cine MRI. Methods One phase of a 4D-MRI acquired during patient simulation is used as patient prior images. 3 major respiratory deformation patterns of the patient are extracted from 4D-MRI based on principal-component-analysis. The on-board VC-MRI at any instant is considered as a deformation of the prior MRI. The deformation field is represented as a linear combination of the 3 major deformation patterns. The coefficients of the deformation patterns are solved by the data fidelity constraint using the acquired on-board single 2D-cine MRI. The method was evaluated using both XCAT simulation of lung cancer patients and MRI data from four real liver cancer patients. The accuracy of the estimated VC-MRI was quantitatively evaluated using Volume-Percent-Difference(VPD), Center-of-Mass-Shift(COMS), and target tracking errors. Effects of acquisition orientation, region-of-interest(ROI) selection, patient breathing pattern change and noise on the estimation accuracy were also evaluated. Results Image subtraction of ground-truth with estimated on-board VC-MRI shows fewer differences than image subtraction of ground-truth with prior image. Agreement between profiles in the estimated and ground-truth VC-MRI was achieved with less than 6% error for both XCAT and patient data. Among all XCAT scenarios, the VPD between ground-truth and estimated lesion volumes was on average 8.43±1.52% and the COMS was on average 0.93±0.58mm across all time-steps for estimation based on the ROI region in the sagittal cine images. Matching to ROI in the sagittal view achieved better accuracy when there was substantial breathing pattern change. The technique was robust against noise levels up to SNR=20. For patient data, average tracking errors were less than 2 mm in all directions for all patients. Conclusions Preliminary studies demonstrated the

  2. A Technique for Generating Volumetric Cine-Magnetic Resonance Imaging.

    Science.gov (United States)

    Harris, Wendy; Ren, Lei; Cai, Jing; Zhang, You; Chang, Zheng; Yin, Fang-Fang

    2016-06-01

    The purpose of this study was to develop a techique to generate on-board volumetric cine-magnetic resonance imaging (VC-MRI) using patient prior images, motion modeling, and on-board 2-dimensional cine MRI. One phase of a 4-dimensional MRI acquired during patient simulation is used as patient prior images. Three major respiratory deformation patterns of the patient are extracted from 4-dimensional MRI based on principal-component analysis. The on-board VC-MRI at any instant is considered as a deformation of the prior MRI. The deformation field is represented as a linear combination of the 3 major deformation patterns. The coefficients of the deformation patterns are solved by the data fidelity constraint using the acquired on-board single 2-dimensional cine MRI. The method was evaluated using both digital extended-cardiac torso (XCAT) simulation of lung cancer patients and MRI data from 4 real liver cancer patients. The accuracy of the estimated VC-MRI was quantitatively evaluated using volume-percent-difference (VPD), center-of-mass-shift (COMS), and target tracking errors. Effects of acquisition orientation, region-of-interest (ROI) selection, patient breathing pattern change, and noise on the estimation accuracy were also evaluated. Image subtraction of ground-truth with estimated on-board VC-MRI shows fewer differences than image subtraction of ground-truth with prior image. Agreement between normalized profiles in the estimated and ground-truth VC-MRI was achieved with less than 6% error for both XCAT and patient data. Among all XCAT scenarios, the VPD between ground-truth and estimated lesion volumes was, on average, 8.43 ± 1.52% and the COMS was, on average, 0.93 ± 0.58 mm across all time steps for estimation based on the ROI region in the sagittal cine images. Matching to ROI in the sagittal view achieved better accuracy when there was substantial breathing pattern change. The technique was robust against noise levels up to SNR = 20. For

  3. Transient refractory material dissolution by a volumetrically-heated melt

    Energy Technology Data Exchange (ETDEWEB)

    Seiler, Jean Marie, E-mail: jean-marie.seiler@cea.fr [CEA, DEN, DTN, 17 Rue des Martyrs, 38054 Grenoble Cedex 9 (France); Ratel, Gilles [CEA, DEN, DTN, 17 Rue des Martyrs, 38054 Grenoble Cedex 9 (France); Combeau, Hervé [Institut Jean Lamour, UMR 7198, Lorraine University, Ecole des Mines de Nancy, Parc de Saurupt, 54042 Nancy Cedex (France); Gaus-Liu, Xiaoyang; Kretzschmar, Frank; Miassoedov, Alexei [Karlsruhe Institut of Technology, Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen (Germany)

    2014-12-15

    Highlights: • We describe a test investigating ceramic dissolution by a molten non-eutectic melt. • The evolution of the interface temperature between melt and refractory is measured. • A theoretical model describing dissolution kinetics is proposed. • When dissolution stops, interface temperature is the liquidus temperature of the melt. - Abstract: The present work addresses the question of corium–ceramic interaction in a core catcher during a core-melt accident in a nuclear power plant. It provides an original insight into transient aspects concerning dissolution of refractory material by a volumetrically heated pool. An experiment with simulant material (LIVECERAM) is presented. Test results clearly show that dissolution of solid refractory material can occur in a non-eutectic melt at a temperature which is lower than the melting temperature of the refractory material. During the dissolution transient, the interface temperature rises above the liquidus temperature, corresponding to the instantaneous average composition of the melt pool. With constant power dissipation in the melt and external cooling of the core-catcher, a final steady-state situation is reached. Dissolution stops when the heat flux (delivered by the melt to the refractory) can be removed by conduction through the residual thickness of the ceramic, with T{sub interface} = T{sub liquidus} (calculated for the average composition of the final liquid pool). The final steady state corresponds to a uniform pool composition and uniform interface temperature distribution. Convection in the pool is governed by natural thermal convection and the heat flux distribution is therefore similar to what would be obtained for a single component pool. An interpretation of the experiment with two model-based approaches (0D and 1D) is presented. The mass transfer kinetics between the interface and the bulk is controlled by a diffusion sublayer within the boundary layer. During the dissolution transient

  4. Volumetric Forest Change Detection Through Vhr Satellite Imagery

    Science.gov (United States)

    Akca, Devrim; Stylianidis, Efstratios; Smagas, Konstantinos; Hofer, Martin; Poli, Daniela; Gruen, Armin; Sanchez Martin, Victor; Altan, Orhan; Walli, Andreas; Jimeno, Elisa; Garcia, Alejandro

    2016-06-01

    Quick and economical ways of detecting of planimetric and volumetric changes of forest areas are in high demand. A research platform, called FORSAT (A satellite processing platform for high resolution forest assessment), was developed for the extraction of 3D geometric information from VHR (very-high resolution) imagery from satellite optical sensors and automatic change detection. This 3D forest information solution was developed during a Eurostars project. FORSAT includes two main units. The first one is dedicated to the geometric and radiometric processing of satellite optical imagery and 2D/3D information extraction. This includes: image radiometric pre-processing, image and ground point measurement, improvement of geometric sensor orientation, quasiepipolar image generation for stereo measurements, digital surface model (DSM) extraction by using a precise and robust image matching approach specially designed for VHR satellite imagery, generation of orthoimages, and 3D measurements in single images using mono-plotting and in stereo images as well as triplets. FORSAT supports most of the VHR optically imagery commonly used for civil applications: IKONOS, OrbView - 3, SPOT - 5 HRS, SPOT - 5 HRG, QuickBird, GeoEye-1, WorldView-1/2, Pléiades 1A/1B, SPOT 6/7, and sensors of similar type to be expected in the future. The second unit of FORSAT is dedicated to 3D surface comparison for change detection. It allows users to import digital elevation models (DEMs), align them using an advanced 3D surface matching approach and calculate the 3D differences and volume changes between epochs. To this end our 3D surface matching method LS3D is being used. FORSAT is a single source and flexible forest information solution with a very competitive price/quality ratio, allowing expert and non-expert remote sensing users to monitor forests in three and four dimensions from VHR optical imagery for many forest information needs. The capacity and benefits of FORSAT have been tested in

  5. Improving plan quality for prostate volumetric-modulated arc therapy.

    Science.gov (United States)

    Wright, Katrina; Ferrari-Anderson, Janet; Barry, Tamara; Bernard, Anne; Brown, Elizabeth; Lehman, Margot; Pryor, David

    2017-08-04

    We critically evaluated the quality and consistency of volumetric-modulated arc therapy (VMAT) prostate planning at a single institution to quantify objective measures for plan quality and establish clear guidelines for plan evaluation and quality assurance. A retrospective analysis was conducted on 34 plans generated on the Pinnacle(3) version 9.4 and 9.8 treatment planning system to deliver 78 Gy in 39 fractions to the prostate only using VMAT. Data were collected on contoured structure volumes, overlaps and expansions, planning target volume (PTV) and organs at risk volumes and relationship, dose volume histogram, plan conformity, plan homogeneity, low-dose wash, and beam parameters. Standard descriptive statistics were used to describe the data. Despite a standardized planning protocol, we found variability was present in all steps of the planning process. Deviations from protocol contours by radiation oncologists and radiation therapists occurred in 12% and 50% of cases, respectively, and the number of optimization parameters ranged from 12 to 27 (median 17). This contributed to conflicts within the optimization process reflected by the mean composite objective value of 0.07 (range 0.01 to 0.44). Methods used to control low-intermediate dose wash were inconsistent. At the PTV rectum interface, the dose-gradient distance from the 74.1 Gy to 40 Gy isodose ranged from 0.6 cm to 2.0 cm (median 1.0 cm). Increasing collimator angle was associated with a decrease in monitor units and a single full 6 MV arc was sufficient for the majority of plans. A significant relationship was found between clinical target volume-rectum distance and rectal tolerances achieved. A linear relationship was determined between the PTV volume and volume of 40 Gy isodose. Objective values and composite objective values were useful in determining plan quality. Anatomic geometry and overlap of structures has a measurable impact on the plan quality achieved for prostate patients

  6. Semi-automated volumetric analysis of artificial lymph nodes in a phantom study.

    Science.gov (United States)

    Fabel, M; Biederer, J; Jochens, A; Bornemann, L; Soza, G; Heller, M; Bolte, H

    2011-12-01

    Quantification of tumour burden in oncology requires accurate and reproducible image evaluation. The current standard is one-dimensional measurement (e.g. RECIST) with inherent disadvantages. Volumetric analysis is discussed as an alternative for therapy monitoring of lung and liver metastases. The aim of this study was to investigate the accuracy of semi-automated volumetric analysis of artificial lymph node metastases in a phantom study. Fifty artificial lymph nodes were produced in a size range from 10 to 55mm; some of them enhanced using iodine contrast media. All nodules were placed in an artificial chest phantom (artiCHEST®) within different surrounding tissues. MDCT was performed using different collimations (1-5 mm) at varying reconstruction kernels (B20f, B40f, B60f). Volume and RECIST measurements were performed using Oncology Software (Siemens Healthcare, Forchheim, Germany) and were compared to reference volume and diameter by calculating absolute percentage errors. The software performance allowed a robust volumetric analysis in a phantom setting. Unsatisfying segmentation results were frequently found for native nodules within surrounding muscle. The absolute percentage error (APE) for volumetric analysis varied between 0.01 and 225%. No significant differences were seen between different reconstruction kernels. The most unsatisfactory segmentation results occurred in higher slice thickness (4 and 5 mm). Contrast enhanced lymph nodes showed better segmentation results by trend. The semi-automated 3D-volumetric analysis software tool allows a reliable and convenient segmentation of artificial lymph nodes in a phantom setting. Lymph nodes adjacent to tissue of similar density cause segmentation problems. For volumetric analysis of lymph node metastases in clinical routine a slice thickness of ≤3mm and a medium soft reconstruction kernel (e.g. B40f for Siemens scan systems) may be a suitable compromise for semi-automated volumetric analysis. Copyright

  7. DENSE: Displacement Encoding with Stimulated Echoes in Cardiac Functional MRI

    Science.gov (United States)

    Aletras, Anthony H.; Ding, Shujun; Balaban, Robert S.; Wen, Han

    1999-03-01

    Displacement encoding with stimulated echoes (DENSE) was developed for high-resolution myocardial displacement mapping. Pixel phase is modulated by myocardial displacement and data spatial resolution is limited only by pixel size. 2D displacement vector maps were generated for the systolic action in canines with 0.94 × 1.9 mm nominal in-plane resolution and 2.3 mm/π displacement encoding. A radial strain of 0.208 was measured across the free left ventricular wall over 105 ms during systole. DENSE displacement maps require small first-order gradient moments for encoding. DENSE magnitude images exhibit black-blood contrast which allows for better myocardial definition and reduced motion-related artifacts.

  8. Distal displacement of the maxilla and the upper first molar.

    Science.gov (United States)

    Baumrind, S; Molthen, R; West, E E; Miller, D M

    1979-06-01

    Data from a sample of 198 Class II cases treated with various appliances which deliver distally directed forces to the maxilla were examined to determine the frequency of absolute distal displacement of the upper first molar and of the maxilla. Analysis revealed that such distal displacement is possible and that it is, in fact, a frequent finding following treatment. Long-range stability of distal displacement was not assessed.

  9. Displacement desorption test of coalbed methane and its mechanism exploring

    Institute of Scientific and Technical Information of China (English)

    ZHANG Suian; HUO Yongzhong; YE Jianping; TANG Shuheng; MA Dongmin

    2005-01-01

    Through the test of CH4 displaced by CO2 using the coal sample as the adsorbent, this paper has found the coalbed methane (CBM) displacement desorption phenomenon under the natural conditions and CBM mining conditions. With the help of the adsorption theory of the modern physical chemistry and interfacial chemistry, the CBM competitive adsorption and displacement desorption mechanism are intensively discussed, and a new path for studying the CBM desorption mechanism in the CBM exploitation process is explored.

  10. Test Rig Design For Compact Variable Displacement Vane Pump

    OpenAIRE

    Chawla, Pratik; Jenkins, Ryan; Ivantysynova, Monika

    2015-01-01

    Variable displacement vane pumps (VDVP) are one type of positive displacement pumps used in automatic transmission vehicles for lubricating the gears, cooling the transmission and actuating the clutches. Though fixed displacement pumps are widely used, they output a constant effective flow at a given speed. Depending on pump sizing considerations, the pump can be oversized at high speeds because flow demand of the transmission is independent of engine speed. The excess flow returns to the tan...

  11. Gingival displacement methods used by dental professionals: A survey

    OpenAIRE

    S V Giridhar Reddy; M.Bharathi; B. Vinod; K Rajeev Kumar Reddy; N Simhachalam Reddy

    2016-01-01

    Aim: The aim of the present study was to identify the methods used by dental professionals for gingival displacement before making impressions for fixed prostheses. Materials and Methods: A printed questionnaire was distributed to over 600 dentists at a National Dental Conference held in Hyderabad. The questionnaire was designed to know the preferred method of gingival displacement, medicament used, frequency of performing gingival displacement, etc. The results were analyzed and represented ...

  12. Employment protection and the consequences for displaced workers

    DEFF Research Database (Denmark)

    Albæk, Karsten; van Audenrode, Marc; Browning, Martin

    We compare the wage and employment consequences of a job displacement in Belgium and Denmark. These two countries both have generous unemployment insurance schemes but job protection laws vary dramatically between the two. Using comparable data we find that the incidence of displacement...... and the consequences for wages are similar in the two countries. The consequences for employment are very different with Danish workers experiencing much less unemployment after a displacement...

  13. Displacement spectra and displacement modification factors, based on records from Greece

    OpenAIRE

    Athanassiadou, C. J.; Karakostas, C. Z.; Margaris, B. N.; Kappos, A. J.

    2011-01-01

    Elastic and inelastic displacement spectra (for periods up to 4.0 s) are derived, using a representative sample of acceleration records from Greece, carefully selected based on magnitude, distance and peak ground acceleration criteria, and grouped into three ground type categories according to the Eurocode 8 (EC8) provisions. The modification factor for the elastic design spectrum adopted in EC8 for accounting for damping is verified herein and is found to be satisfactory in the short to medi...

  14. Volumetric elasticity imaging with a 2-D CMUT array.

    Science.gov (United States)

    Fisher, Ted G; Hall, Timothy J; Panda, Satchi; Richards, Michael S; Barbone, Paul E; Jiang, Jingfeng; Resnick, Jeff; Barnes, Steve

    2010-06-01

    This article reports the use of a two-dimensional (2-D) capacitive micro-machined ultrasound transducer (CMUT) to acquire radio-frequency (RF) echo data from relatively large volumes of a simple ultrasound phantom to compare three-dimensional (3-D) elasticity imaging methods. Typical 2-D motion tracking for elasticity image formation was compared with three different methods of 3-D motion tracking, with sum-squared difference (SSD) used as the similarity measure. Differences among the algorithms were the degree to which they tracked elevational motion: not at all (2-D search), planar search, combination of multiple planes and plane independent guided search. The cross-correlation between the predeformation and motion-compensated postdeformation RF echo fields was used to quantify motion tracking accuracy. The lesion contrast-to-noise ratio was used to quantify image quality. Tracking accuracy and strain image quality generally improved with increased tracking sophistication. When used as input for a 3-D modulus reconstruction, high quality 3-D displacement estimates yielded accurate and low noise modulus reconstruction.

  15. Isothermal Gas assisted displacement of a polystyrene melt

    DEFF Research Database (Denmark)

    Eriksson, Torbjörn Gerhard; Rasmussen, Henrik K.

    2007-01-01

    Isothermal gas displacements of a polystyrene melt (shaped as circular cylinder with a radius of 2.5mm) placed inside a circular steel annulus were performed. A flow valve ensures a constant flow rate and rotational symmetric flow during the displacement. The experiments show an increase in the s......Isothermal gas displacements of a polystyrene melt (shaped as circular cylinder with a radius of 2.5mm) placed inside a circular steel annulus were performed. A flow valve ensures a constant flow rate and rotational symmetric flow during the displacement. The experiments show an increase...

  16. Studying Landslide Displacements in Megamendung (Indonesia Using GPS Survey Method

    Directory of Open Access Journals (Sweden)

    Hasanuddin Z. Abidin

    2004-11-01

    Full Text Available Landslide is one of prominent geohazards that frequently affects Indonesia, especially in the rainy season. It destroys not only environment and property, but usually also causes deaths. Landslide monitoring is therefore very crucial and should be continuously done. One of the methods that can have a contribution in studying landslide phenomena is repeated GPS survey method. This paper presents and discusses the operational performances, constraints and results of GPS surveys conducted in a well known landslide prone area in West Java (Indonesia, namely Megamendung, the hilly region close to Bogor. Three GPS surveys involving 8 GPS points have been conducted, namely on April 2002, May 2003 and May 2004, respectively. The estimated landslide displacements in the area are relatively quite large in the level of a few dm to a few m. Displacements up to about 2-3 m were detected in the April 2002 to May 2003 period, and up to about 3-4 dm in the May 2003 to May 2004 period. In both periods, landslides in general show the northwest direction of displacements. Displacements vary both spatially and temporally. This study also suggested that in order to conclude the existence of real and significant displacements of GPS points, the GPS estimated displacements should be subjected to three types of testing namely: the congruency test on spatial displacements, testing on the agreement between the horizontal distance changes with the predicted direction of landslide displacement, and testing on the consistency of displacement directions on two consecutive periods.

  17. Downward finger displacement distinguishes Parkinson disease dementia from Alzheimer disease.

    Science.gov (United States)

    Lieberman, Abraham; Deep, Aman; Shi, Jiong; Dhall, Rohit; Shafer, Saulena; Moguel-Cobos, Guillermo; Dhillon, Ravneet; Frames, Christopher W; McCauley, Margaret

    2017-09-15

    Purpose/Aim of the study: To study finger displacement in patients with Parkinson disease dementia (PDD) and in patients with Alzheimer disease (AD). We examined 56 patients with PDD and 35 with AD. Patients were examined during their regular outpatient clinic visit. Finger displacement was measured by observers not actively involved in the study using a creative grid ruler for all PDD and AD patients. Finger displacement was examined by asking patients to point their index fingers toward the grid ruler with the nails facing upward. Patients were asked to maintain the pointing position for 15 s. After 15 s, patients were asked to close their eyes for another 15 s while maintaining the same position. A positive result was downward index finger displacement of ≥5 cm within the 15-second time window with eyes closed. Of the 56 PDD patients, 53 had bilateral finger displacement of > 5 cm. In comparison, of the 35 AD patients, only 1 patient had minimal displacement. Results of the non-invasive finger displacement test may provide insight, on an outpatient basis, of the integrity of subcortical-cortical circuits. Downward finger displacement, especially bilateral downward displacement, may signal the extensive disruption of subcortical-cortical circuits that occurs in PDD patients.

  18. The Three Gorges: the unexamined toll of development-induced displacement

    OpenAIRE

    Martin Stein

    1998-01-01

    In China, the context of forced displacement in its broadest sense centres on four issues: (1) coercive displacement for development; (2) political persecution resulting in controlled displacement; (3) massive labour dislocations; and (4) disaster-induced displacement. This article looks at the role of the state in displacement, focusing on the first of these issues: development-induced displacement.

  19. The effects of dimensional mould sizes on volumetric shrinkage strain of lateritic soil

    Directory of Open Access Journals (Sweden)

    John Engbonye SANI

    2016-07-01

    Full Text Available Dimensional influences of specimen size on the volumetric shrinkage strain values of a lateritic soil for waste containment system have not been researched upon. Therefore, this paper presents the result of a laboratory study on the volumetric shrinkage strain (VSS of lateritic soil at three different dimensional sizes of mould (split former mould, proctor mould and California bearing ratio mould at three energy levels; British standard light (BSL, West African standard (WAS and British standard heavy (BSH respectively. Compactions were done at different molding water content of -2% to +6% optimum moisture content (OMC. At -2% to +2% molding water content for the split former mould the volumetric shrinkage strain met the requirement of not more than 4% while at +4% and +6% only the WAS and BSH met the requirement. The proctor mould and the CBR mould on the other hand gave a lower value of volumetric shrinkage strain in all compactive effort and the values are lower than the 4% safe VSS suggested by Tay et al., (2001. Based on the VSS values obtained if the CBR mould can be used to model site condition it is recommended for use to simulate site condition for Volumetric shrinkage strain for all molding water content and compactive effort.

  20. Semi-automated volumetric analysis of lymph node metastases during follow-up--initial results.

    Science.gov (United States)

    Fabel, Michael; Bolte, H; von Tengg-Kobligk, H; Bornemann, L; Dicken, V; Delorme, S; Kauczor, H-U; Heller, M; Biederer, J

    2011-04-01

    Quantification of tumour burden in oncology requires accurate and reproducible evaluation. The current standard is RECIST measurement with its inherent disadvantages. Volumetric analysis is an alternative for therapy monitoring. The aim of this study was to evaluate the feasibility of volumetric analysis of lymph node metastases using a software prototype in a follow-up setting. MSCT was performed in 50 patients covering the chest, abdomen and pelvis. A total of 174 suspicious lymph nodes were evaluated by two radiologists regarding short axis diameters and volumetric analysis using semi-automated software. Quality of segmentation, time, maximum diameter and volume were documented. Variability of the derived change rates was computed as the standard deviation of the difference of the obtained respective change rates. The software performance provides robust volumetric analysis. Quality of segmentation was rated acceptable to excellent in 76-79% by each reader. Mean time spent per lesion was 38 s. The variability of change in effective diameters was 10.6%; for change rates of RECIST maximum diameter variability was 27.5%. Semi-automated volumetric analysis allows fast and convenient segmentation of most lymph node metastases. Compared with RECIST the inter-observer-variability in baseline and follow-up is reduced. This should principally allow subtle changes to be subclassified within the RECIST stable range as minor response [-15% to +10%].

  1. Displacement of the ventricular fold following cordectomy.

    Science.gov (United States)

    Fukuda, H; Tsuji, D H; Kawasaki, Y; Kawaida, M; Sakou, T

    1990-01-01

    In order to avoid radiation and its undesirable side effects, we have employed surgical techniques for treatment of early glottic cancer when the lesion is confined to one membranous cord (Fukuda, Saito, Sato, and Kitahara: J. Jpn. Bronchoesophagol. Soc. 30: 7-14, 1979; Fukuda and Saito: Otologica 26: 434-436, 1980; Fukuda, Kawaida, Ohki, Kawasaki, Kita, and Tatehara: J. Jpn. Bronchoesophagaol. Soc. 39: 139-144, 1988). Laser is one of the most popular techniques and it has been accepted as the first choice by many authors (Annyas, Overbeek, Escajadillo, and Hoeksema: Laryngoscope 94: 836-838, 1984; Mcguirt and Koufman: Arch. Otolaryngol. Head Neck Surg. 113: 501-505, 1987; Tsuji, Fukuda, Kawaskai, Kawaida, and Kanzaki: Keio J. Med. 38: 413-418, 1989). However, some cases are difficult to approach by direct laryngoscopy, requiring an external way to expose the lesion. In these cases, cordectomy by laryngofissure is the method of choice, but the function of the glottis could be improved by replacing the excised cord displacing the ventricular fold. This technique, designed by the authors, was carried out in 22 patients and the results from the viewpoint of phonodynamics, voice quality, and cure rate are discussed in this study. The results are encouraging and we believe that this method is a very reasonable alternative to the laser when such equipment is not available. We also believe that late side effects and oncogenic problems associated with radiation are important points to be considered, especially in patients of relatively younger age.

  2. Motional displacements in proteins incorporating dynamical diversity

    Science.gov (United States)

    Vural, Derya; Smith, Jeremy; Glyde, Henry

    The average mean square displacement (MSD), , of hydrogen H in proteins is measured using incoherent neutron scattering methods. The observed MSD shows a marked increase in magnitude at a temperature TD ~= 240 K. This is widely interpreted as a dynamical transition to large MSDs which make function possible in proteins. However, when the data is interpreted in terms of a single averaged MSD, the extracted depends on the neutron momentum transfer, ℏQ , used in the measurement. We have shown recently that this apparent dependence on Q arises because the dynamical diversity of the H in the protein is neglected[2]. We present models of the dynamical diversity of H in Lysosyme that when used in the analysis of simulated neutron data lead to consistent, Q independent values for the average MSD and for the diversity model.2. D. Vural and L. Hong, J. C. Smith and H. R. Glyde. Phys. Rev. E 91, 052705 (2015). Supported in part by Office of Basic Energy Sciences, USDOE, ER46680.

  3. TREATMENT OF DISPLACED MALLEOLAR FRACTURES AT CHILDREN

    Directory of Open Access Journals (Sweden)

    Franci Vindišar

    2004-04-01

    Full Text Available Background. The exact knowledge of the anatomic relations of the juvenile skeleton is of great importance for the determination of the injury and proper treatment. The treatment should be uniform and carried out in one act. Considering this facts the functional results are usually very good and no late sequel are recorded.Methods. In 5-years period 25 children with age 7 to 17 were treated with displaced fracture of ankle. The Salter-Harris classification (SHC was used. Children were classified in two groups. In first group (G-I 11 children were treated with closed reduction. Whole group was classified as type II fractures of SHC. In second group (G-II 14 children were treated operatively. 10 cases were type III, 2 cases were type IV of SHC and 2 were juvenil Tillaux fracture. In follow-up we registered the duration of immobilisation, non-weight bearing period, mobility and residual pain at the end of the treatment.Results. In G-I average non-weight bearing period was 10.4 weeks, in G-II only 7.8 weeks. At the end of the treatment in both groups very good functional results were achieved. There were no complications in operative group (G-II.Conclusions. Children relatively often suffer ankle injuries. With proper diagnosis and early adequate treatment the prognosis is good and no functional sequel were recorded.

  4. Mythic displacement in Nigerian narratives: An introduction

    Directory of Open Access Journals (Sweden)

    Ignatius Chukwumah

    2013-12-01

    Full Text Available http://dx.doi.org/10.5007/2175-8026.2013n65p73 Five decades of resorting to humanistic critical procedureshave bequeathed to the Nigerian critical practice the legacy ofexamining and discovering in Nigerian and African narrativesthe historical and social concepts of the time and times theyare presumed to posit. These concepts include colonialism,corruption, war, political instability, and culture conflict. Theseprocedures are undertaken without due regard to seeing the wholeof the literary tradition as a stream out of which narratives emerge.This article, therefore, by way of introduction, seeks to retrieveNigerian narratives from “every author” and humanistic criticalapproach by placing them in a realm where a holistic method suchas Frye’s could be applied. Here, the traverses of the structure ofmythical imagery such as the mythos of crime and punishmentas embodied in these narratives and how this structure wasdisplaced/shrouded from Frye’s first mimetic mode to the last, viathe concept of mythic displacement, will be analysed.

  5. VOLUMETRIC MASS TRANSFER COEFFICIENT BETWEEN SLAG AND METAL IN COMBINED BLOWING CONVERTER

    Institute of Scientific and Technical Information of China (English)

    Z.H. Wu; Z.S. Zou; W. Wu

    2005-01-01

    The effects of operation parameters of combined blowing converter on the volumetric mass transfer coefficient between slag and steel are studied with a cold model with water simulating steel, oil simulating slag and benzoic acid as the transferred substance between water and oil. The results show that, with lance level of 2.Im and the top blowing rate of 25000Nm3/h, the volumetric mass transfer coefficient changes most significantly when the bottom blowing rate ranges from 384 to 540Nm3/h. The volumetric mass transfer coefficient reaches its maximum when the lance level is 2. lm, the top blowing rates is 30000Nm3/h, and the bottom blowing rate is 384Nrr3/h with tuyeres located symmetrically at 0.66D of the converter bottom.

  6. Control and design of volumetric composition in pultruded hybrid fibre composites

    DEFF Research Database (Denmark)

    Madsen, Bo; Hashemi, Fariborz; Tahir, Paridah

    2016-01-01

    Hybrid composites consist of two of more fibre phases in a common matrix phase. This is a challenge for the control and design of the volumetric composition and microstructural uniformity of such composites. In the present study, a model is presented for the prediction of the complete volumetric...... composition (i.e. volume fractions of fibres, matrix and porosity) in hybrid fibre composites. The model is based on a constant local fibre volume fraction criterion. Good agreement is found between model predictions and experimental data of pultruded hybrid kenaf/glass fibre composites with variable hybrid...... fibre weight mixing ratios. To demonstrate the suitability of the model, simulations are performed for four different cases of volumetric composition in hybrid kenaf/glass composites....

  7. NDE Technology Development Program for Non-Visual Volumetric Inspection Technology; Sensor Effectiveness Testing Report

    Energy Technology Data Exchange (ETDEWEB)

    Moran, Traci L.; Larche, Michael R.; Denslow, Kayte M.; Glass, Samuel W.

    2017-08-31

    The Pacific Northwest National Laboratory (PNNL) located in Richland, Washington, hosted and administered Sensor Effectiveness Testing that allowed four different participants to demonstrate the NDE volumetric inspection technologies that were previously demonstrated during the Technology Screening session. This document provides a Sensor Effectiveness Testing report for the final part of Phase I of a three-phase NDE Technology Development Program designed to identify and mature a system or set of non-visual volumetric NDE technologies for Hanford DST primary liner bottom inspection. Phase I of the program will baseline the performance of current or emerging non-visual volumetric NDE technologies for their ability to detect and characterize primary liner bottom flaws, and identify candidate technologies for adaptation and maturation for Phase II of the program.

  8. Ultrahigh volumetric capacitance and cyclic stability of fluorine and nitrogen co-doped carbon microspheres

    Science.gov (United States)

    Zhou, Junshuang; Lian, Jie; Hou, Li; Zhang, Junchuan; Gou, Huiyang; Xia, Meirong; Zhao, Yufeng; Strobel, Timothy A.; Tao, Lu; Gao, Faming

    2015-09-01

    Highly porous nanostructures with large surface areas are typically employed for electrical double-layer capacitors to improve gravimetric energy storage capacity; however, high surface area carbon-based electrodes result in poor volumetric capacitance because of the low packing density of porous materials. Here, we demonstrate ultrahigh volumetric capacitance of 521 F cm-3 in aqueous electrolytes for non-porous carbon microsphere electrodes co-doped with fluorine and nitrogen synthesized by low-temperature solvothermal route, rivaling expensive RuO2 or MnO2 pseudo-capacitors. The new electrodes also exhibit excellent cyclic stability without capacitance loss after 10,000 cycles in both acidic and basic electrolytes at a high charge current of 5 A g-1. This work provides a new approach for designing high-performance electrodes with exceptional volumetric capacitance with high mass loadings and charge rates for long-lived electrochemical energy storage systems.

  9. Combination volumetric and gravimetric sorption instrument for high accuracy measurements of methane adsorption

    Science.gov (United States)

    Burress, Jacob; Bethea, Donald; Troub, Brandon

    2017-05-01

    The accurate measurement of adsorbed gas up to high pressures (˜100 bars) is critical for the development of new materials for adsorbed gas storage. The typical Sievert-type volumetric method introduces accumulating errors that can become large at maximum pressures. Alternatively, gravimetric methods employing microbalances require careful buoyancy corrections. In this paper, we present a combination gravimetric and volumetric system for methane sorption measurements on samples between ˜0.5 and 1 g. The gravimetric method described requires no buoyancy corrections. The tandem use of the gravimetric method allows for a check on the highest uncertainty volumetric measurements. The sources and proper calculation of uncertainties are discussed. Results from methane measurements on activated carbon MSC-30 and metal-organic framework HKUST-1 are compared across methods and within the literature.

  10. Single step full volumetric reconstruction optical coherence tomography utilizing compressive sensing

    Science.gov (United States)

    Chen, Luoyang; Liu, Jiansheng; cheng, Jiangtao; Liu, Haitao; Zhou, Hongwen

    2017-03-01

    3D optical coherence tomography imaging (OCT) combined with compressive sensing (CS) has been proved to be an attractive and effective tool in a variety of fields, such as medicine and biology. To achieve high quality imaging while using as less CS sampling rate as possible is the goal of this approach. Here we present an innovative single step fully 3D CS-OCT volumetric image recovery method, in which 3D OCT volumetric image of the object is compressively sampled via our proposed CS coding strategies in all three dimensions while its sparsity is simultaneously taken into consideration in every direction. The object can be directly recovered as the whole volume reconstruction via our advanced full 3D CS reconstruction algorithm. The numerical simulations of a human retina OCT volumetric image reconstruction by our method demonstrate a PSNR of as high as 38dB at a sampling rate of less than 10%.

  11. Seeding optimization for instantaneous volumetric velocimetry. Application to a jet in crossflow

    CERN Document Server

    Cambonie, Tristan

    2014-01-01

    Every volumetric velocimetry measurements based on tracer (particles, bubbles, etc.) detection can be strongly influenced by the optical screening phenomenon. It has to be taken into account when the the statistical properties associated to the performances of the particle detection and tracking algorithms are significantly affected. It leads to a maximum concentration of particles in the images thus limiting the final spatial resolution of the instantaneous three-dimensional three-components (3D3C) velocity fields. A volumetric velocimetry system based on Defocused Digital Particle Image Velocimetry is used to show that above a critical visual concentration of particles in the images, the concentration and accuracy of the final instantaneous raw velocity vector field drop. The critical concentration depends on physical parameters as well as on the processing algorithms. Three distinct regimes are identified. In the first regime, the concentration is well adapted to volumetric velocimetry, the largest concent...

  12. Uniform stability of displacement coupled second-order equations

    Directory of Open Access Journals (Sweden)

    Abdelaziz Soufyane

    2001-04-01

    Full Text Available We prove that the uniform stability of semigroups associated to displacement coupled dissipator systems is equivalent to the uniform stability of velocity coupled dissipator systems. Using this equivalence, we give sufficient conditions for obtaining uniform stability and exact controllability of displacement coupled dissipator systems.

  13. Simple and economical capacitive displacement system for UHV operation.

    Science.gov (United States)

    Chow, R; Tiller, W A

    1979-12-01

    A parallel plate capacitor was assembled as a displacement transducer for operation in an UHV environment. The capacitive displacement system was linear over a 2.5 mum range with a resolution of 0.051 mum. Components in the electric circuit were common laboratory instruments.

  14. Isothermal Gas assisted displacement of a polystyrene melt

    DEFF Research Database (Denmark)

    Eriksson, Torbjörn Gerhard; Rasmussen, Henrik K.

    2007-01-01

    Isothermal gas displacements of a polystyrene melt (shaped as circular cylinder with a radius of 2.5mm) placed inside a circular steel annulus were performed. A flow valve ensures a constant flow rate and rotational symmetric flow during the displacement. The experiments show an increase in the s...

  15. Traumatisk diafragmaruptur med displacering af leveren til thorax

    DEFF Research Database (Denmark)

    Hornstrup, L.; Burcharth, F.

    2008-01-01

    We report a case of a traumatic diaphragmatic rupture with the liver displaced to the right hemithorax. MR diagnosed the rupture and the displacement of the liver. The patient was operated on and the total right diaphragmatic rupture was reconstructed by suturing. Traumatic diaphragmatic rupture ...

  16. Study on the applicability of the desk displacement ventilation concept

    NARCIS (Netherlands)

    Loomans, Marcel G.L.C.

    1999-01-01

    This paper summarizes an experimental and numerical study into a ventilation concept that combines displacement ventilation with task conditioning, the so-called desk displacement ventilation (DDV) concept. The study uses steady-state and transient results to discuss the applicability of the DDV con

  17. Displacement Ventilation in a Room with Low-Level Diffusers

    DEFF Research Database (Denmark)

    Nielsen, Peter V.

    Ventilation systems with vertical displacement flow have been used in industrial areas with high thermal loads for many years. Quite resently the vertical displacement flow systems have grown popular as comfort ventilation in rooms with thermal loads e.g. offices....

  18. Laser phase-detector and counter for fine displacement measurement

    Science.gov (United States)

    Row, R. T.; Wang, C. P.

    A simple technique for the measurement of fine displacement has been developed. With use of an HeNe laser, an optical phase-detector, and counter, a displacement accuracy of 300 nm has been demonstrated over a range of 2 cm.

  19. Displacement, Outplacement, or Inplacement? Options for Business and Industry.

    Science.gov (United States)

    Wiltzius, Thomas J.

    This report considers the differences among displacement, outplacement, and inplacement and looks at the risks, benefits, and costs of each. Displacement is defined as the termination of employment with little attention given to corporate or individual needs. Outplacement is defined as the pre-planned management of employee termination, addressing…

  20. Single Parent or Displaced Homemaker Program Management Guide.

    Science.gov (United States)

    Utah State Office of Education, Salt Lake City. Div. of Vocational Education.

    This guide is designed to provide vocational education, single parent/displaced homemaker program directors, and other interested persons with information to help them support, establish, and conduct programs for single parents or displaced homemakers in the nine vocational education planning regions of Utah. It includes definitions and staff…

  1. 24 CFR 886.338 - Displacement, relocation, and acquisition.

    Science.gov (United States)

    2010-04-01

    ... regulations at 49 CFR part 24. A “displaced person” shall be advised of his or her rights under the Fair... persons. A “displaced person” (defined in paragraph (g) of this section) must be provided relocation... the requirements described in 49 CFR part 24, subpart B. (e) Appeals. A person who disagrees with...

  2. Displacement and Force Measurements with Quadrant Photodetector in Optical Tweezers

    Institute of Scientific and Technical Information of China (English)

    郭红莲; 刘春香; 李兆霖; 段建发; 韩学海; 程丙英; 张道中

    2003-01-01

    A technique of displacement and force measurements with a photodiode quadrant detector in an optical tweezers system is presented. The stiffness of optical trap is calibrated and the leukemia cell membrane tension is measured.The results show that the optical tweezers combined with the quadrant detector is a very useful tool for detecting the displacement and force with a millisecond-order response.

  3. Forced displacement: a development issue with humanitarian elements

    OpenAIRE

    Niels Harild

    2016-01-01

    Work on conflict-induced forced displacement is at a crucial moment, at a tipping point. Now is the time to consolidate the shift towards full global recognition that the challenge of forced displacement is an integral part of the development agenda too.

  4. 24 CFR 236.1001 - Displacement, relocation, and acquisition.

    Science.gov (United States)

    2010-04-01

    ... reasonable steps to minimize the displacement of persons (households, businesses, nonprofit organizations... temporarily to permit rehabilitation or other work for the assisted project. Such tenants must be provided: (1... shall maintain data on the race, ethnic, gender, and disability status of displaced persons....

  5. A Reference Optical System of Laser Doppler Longitudinal Displacement Measurement

    Institute of Scientific and Technical Information of China (English)

    张存满; 赵洋; 李达成

    2001-01-01

    In this paper, a new reference optical system is put forward to achieve longitudinal displacement measurement. An optical grating is used for frequency mixing and getting high SNR signals in the measurement. Conditions and methods for getting Doppler beat signals are presented.The experiments indicate that this optical syetem can be used to measure the longitudinal displacement with high accuracy.

  6. Retention of Displaced Students after Hurricanes Katrina and Rita

    Science.gov (United States)

    Coco, Joshua Christian

    2017-01-01

    The purpose of the study was to investigate the strategies that university leaders implemented to improve retention of displaced students in the aftermaths of Hurricanes Katrina and Rita. The universities that participated in this study admitted displaced students after Hurricanes Katrina and Rita. This study utilized a qualitative…

  7. Hyoid Displacement in Post-Treatment Cancer Patients: Preliminary Findings

    Science.gov (United States)

    Zu, Yihe; Yang, Zhenyu; Perlman, Adrienne L.

    2011-01-01

    Purpose: Dysphagia after head and neck cancer treatment is a health care issue; in some cases, the cause of death is not cancer but, rather, the passage of food or liquid into the lungs. Hyoid displacement is known to be important to safe swallowing function. The purpose of this study was to evaluate hyoid displacement after cancer treatment.…

  8. Scaling of interface displacement in a microfluidic comparator

    NARCIS (Netherlands)

    Vanapalli, S.A.; Ende, van den D.; Duits, M.H.G.; Mugele, F.

    2007-01-01

    The authors quantify both experimentally and theoretically the scaling behavior between interface displacement and excess pressure drop in a microfluidic comparator. Unlike previous studies, the authors measure the interface displacement in the outlet channel of the comparator that yields a unique p

  9. The effect of bone displacement operations on facial soft tissues.

    Science.gov (United States)

    Habib, Ali; Hisham, Ahmed

    2013-01-01

    A novel biomechanical model for face soft tissue (skin, mucosa, and muscles) is introduced to investigate the effect of mandible and chin bone displacement on the overall appearance of the patient's face. Nonlinear FE analysis is applied to the model and the results obtained are used to help surgeons to decide the amount of displacement required.

  10. The use of crosshead displacement in determining fracture parameters

    NARCIS (Netherlands)

    Walters, C.L.; Voormeeren, L.O.; Janssen, M.

    2013-01-01

    In determining the fracture toughness of a test specimen, standards currently require either locally-measured load-line displacements or clip gage displacements. In order to measure these parameters, secondary sensors generally need to be installed and calibrated, which often comes at a higher cost.

  11. Displacement, Outplacement, or Inplacement? Options for Business and Industry.

    Science.gov (United States)

    Wiltzius, Thomas J.

    This report considers the differences among displacement, outplacement, and inplacement and looks at the risks, benefits, and costs of each. Displacement is defined as the termination of employment with little attention given to corporate or individual needs. Outplacement is defined as the pre-planned management of employee termination, addressing…

  12. Fiber-coupled displacement interferometry without periodic nonlinearity

    NARCIS (Netherlands)

    Ellis, J.D.; Meskers, A.J.H.; Spronck, J.W.; Munnig Schmidt, R.H.

    2011-01-01

    Displacement interferometry is widely used for accurately characterizing nanometer and subnanometer displacements in many applications. In many modern systems, fiber delivery is desired to limit optical alignment and remove heat sources from the system, but fiber delivery can exacerbate common inter

  13. Measurements of vertical displacements Apollo bridge in Bratislava

    Directory of Open Access Journals (Sweden)

    Vlastimil Staněk

    2009-11-01

    Full Text Available Apollo bridge across the Danube river in Bratislava - description of construction parts. Reference network and long-termmeasurements of displacements. Measurements of vertical displacements of bridge pillars using levelling instruments DiNi 12and Ni 007 and stability testing of the reference points.

  14. Forced displacement: a development issue with humanitarian elements

    Directory of Open Access Journals (Sweden)

    Niels Harild

    2016-05-01

    Full Text Available Work on conflict-induced forced displacement is at a crucial moment, at a tipping point. Now is the time to consolidate the shift towards full global recognition that the challenge of forced displacement is an integral part of the development agenda too.

  15. Volumetric Concentration Maximum of Cohesive Sediment in Waters: A Numerical Study

    Directory of Open Access Journals (Sweden)

    Jisun Byun

    2014-12-01

    Full Text Available Cohesive sediment has different characteristics compared to non-cohesive sediment. The density and size of a cohesive sediment aggregate (a so-called, floc continuously changes through the flocculation process. The variation of floc size and density can cause a change of volumetric concentration under the condition of constant mass concentration. This study investigates how the volumetric concentration is affected by different conditions such as flow velocity, water depth, and sediment suspension. A previously verified, one-dimensional vertical numerical model is utilized here. The flocculation process is also considered by floc in the growth type flocculation model. Idealized conditions are assumed in this study for the numerical experiments. The simulation results show that the volumetric concentration profile of cohesive sediment is different from the Rouse profile. The volumetric concentration decreases near the bed showing the elevated maximum in the cases of both current and oscillatory flow. The density and size of floc show the minimum and the maximum values near the elevation of volumetric concentration maximum, respectively. This study also shows that the flow velocity and the critical shear stress have significant effects on the elevated maximum of volumetric concentration. As mechanisms of the elevated maximum, the strong turbulence intensity and increased mass concentration are considered because they cause the enhanced flocculation process. This study uses numerical experiments. To the best of our knowledge, no laboratory or field experiments on the elevated maximum have been carried out until now. It is of great necessity to conduct well-controlled laboratory experiments in the near future.

  16. [Vestibularly displaced flap with bone augmentation].

    Science.gov (United States)

    Bakalian, V L

    2009-01-01

    The aim of this study is to achieve esthetic gingival contours with the help of less traumatic mucogingival surgeries. 9 Patients were operated with horizontal deficiencies in 9 edentulous sites, planned to be restored with fixed partial dentures. In all cases there was lack of keratinized tissues. Temporary bridges were fabricated to all patients. Before surgery the bridges were removed and the abutment teeth were additionally cleaned with ultrasonic device. A horizontal incision was made from lingual (palatal) side between the abutment teeth, which was connected with two vertical releasing incisions to the mucogingival junction from the vestibular side. The horizontal incision was made on a distance 6-10 mm from the crest of the alveolar ridge. A partial thickness flap in the beginning 3-5 mm, then a full thickness flap up to the mucogingival junction, then a partial thickness flap was made. The flap was mobilized and displaced vestibularly. In the apical part the cortical bone was perforated, graft material was put and the flap was sutured. In all 9 cases the horizontal defect was partially or fully eliminated. The width of the keratinized tissues was also augmented in all cases. The postoperative healing was without complications, discomfort and painless. The donor sites also healed without complications. The application of Solcoseryl Dental Adhesive Paste 3 times a day for 7-10 days helped for painless healing of the donor site. The offered method of soft tissue and bone augmentation is effective in the treatment of horizontal defects of edentulous alveolar ridges of not big sizes. It makes possible to achieve esthetic results without traumatizing an additional donor-site.

  17. Displacement ventilation and passive cooling strategies

    Energy Technology Data Exchange (ETDEWEB)

    Carew, P.; Bekker, B. [PJCarew Consulting, Cape Town (South Africa)

    2009-07-01

    Displacement ventilation (DV) is widely used a passive cooling strategy because it requires less air supply for cooling compared to conventional mixing ventilation (MV). DV introduces air at low level and low velocity, and at high supply air temperature, usually around 18 degrees C. The slightly cooler air runs along the floor of a room until it reaches a heat load. The heat load induces a plume of warmer air that rises due to lower density. This induces stratification in room temperature with the occupied area of the room. The air near the ceiling is continually exhausted to prevent a build up of warm air into the occupied zone. This paper demonstrated the impacts of using DV in comparison to MV on the peak capacity, size and humidity levels associated with various passive cooling strategies, informed by the ASHRAE DV guidelines. A generic office building in Johannesburg, South Africa, was used as a model. The paper illustrated the extent to which DV can be used as a passive cooling strategy in spaces that were previously considered as having too high a heat load when calculated using MV system guidelines. A comparison of DV and MV also highlighted the risk of over-design when conventional MV guidelines are used to design cooling sources for DV applications. The DV was shown to significantly lower the amount of supply air needed to serve a room's heat load when compared to MV at the same temperatures. This reduction in air supply impacts the feasibility of using passive cooling strategies in evaporative cooling, 2-stage evaporative cooling, thermal storage and air to ground heat exchangers. However, passive cooling strategies are unlikely to be widely implemented until design guidelines are created by organizations such as ASHRAE. 8 refs., 2 tabs., 15 figs.

  18. Surgical treatment of displaced acetabular fractures

    Directory of Open Access Journals (Sweden)

    Milenković Saša

    2011-01-01

    Full Text Available Introduction. Acetabular fractures are severe injuries, generally caused by high-energy trauma, most frequently from traffic accidents or falls from heights. Fractures of the extremities, head injuries, chest, abdomen and pelvic ring injuries are most commonly associated injuries. Objective. The purpose of this study was to evaluate the results of open reduction and internal fixation of acetabular fractures. The open anatomical reduction of the articular surface combined with a rigid internal fixation and early mobilisation have become the standard treatment of these injuries. Methods. We conducted a retrospective analysis of 22 patients of average age 43.13 years. The patients were treated by open reduction and internal fixation at the Orthopaedic Clinic of Niš from 2005-2009. The follow-up was 12 to 60 months, with the average of 21.18 months after surgery. Results. All injured patients were operated on between 4 and 11 days (5.7 days on the average. According to the classification by Judet and Letournel, 15 (68.18% patients had an elementary acetabular fracture, whereas 7 (31.82% patients had associated fracture. A satisfactory postoperative reduction implying less than 2 mm of displacement was achieved in 19 (86.36% patients. The radiological status of the hip joint, determined according to Matta score, was excellent in 15 (68.18% patients, good in 4 (18.18% patients and moderate in 3 (13.63% patients. According to Merle d’Aubigné Scale, the final functional results of the treatment of all operated patients were excellent in 12 (54.54% patients, good in 7 (31.81% patients and moderate in 3 (13.63% patients. Conclusion. Surgical treatment of dislocated acetabular fractures requires an open reduction and a stable internal fixation. Excellent and good results can be expected only if anatomical reduction and stable internal fixation are achieved.

  19. Displacement of soil pore water by trichloroethylene

    Science.gov (United States)

    Wershaw, R. L.; Aiken, G.R.; Imbrigiotta, T.E.; Goldberg, M.C.

    1994-01-01

    Dense nonaqueous phase liquids (DNAPLS) are important pollutants because of their widespread use as chemical and industrial solvents. An example of the pollution caused by the discharge of DNAPLs is found at the Picatinny Arsenal, New Jersey, where trichloroethylene (TCE) has been discharged directly into the unsaturated zone. This discharge has resulted in the formation of a plume of TCE-contaminated water in the aquifer downgradient of the discharge. A zone of dark-colored groundwater containing a high dissolved organic C content has been found near the point of discharge of the TCE. The colored-water plume extends from the point of discharge at least 30 m (100 feet) downgradient. Fulvic acids isolated from the colored-waters plume, from water from a background well that has not been affected by the discharge of chlorinated solvents, and from soil pore water collected in a lysimeter installed at an uncontaminated site upgradient of the study area have been compared. Nuclear magnetic resonance spectra of the fulvic acids from the colored waters and from the lysimeter are very similar, but are markedly different from the nuclear magnetic resonance spectrum of the fulvic acid from the background well. The three-dimensional fluorescence spectrum and the DOC fractionation profile of the colored groundwater and the soil pore water are very similar to each other, but quite different from those of the background water. It is proposed from these observations that this colored water is soil pore water that has been displaced by a separate DNAPL liquid phase downward to the saturated zone.

  20. How minimum detectable displacement in a GNSS Monitoring Network change?

    Science.gov (United States)

    Hilmi Erkoç, Muharrem; Doǧan, Uǧur; Aydın, Cüneyt

    2016-04-01

    The minimum detectable displacement in a geodetic monitoring network shows the displacement magnitude which may be just discriminated with known error probabilities. This displacement, which is originally deduced from sensitivity analysis, depends on network design, observation accuracy, datum of the network, direction of the displacement and power of the statistical test used for detecting the displacements. One may investigate how different scenarios on network design and observation accuracies influence the minimum detectable displacements for the specified datum, a-priorly forecasted directions and assumed power of the test and decide which scenario is the best or most optimum. It is sometimes difficult to forecast directions of the displacements. In that case, the minimum detectable displacements in a geodetic monitoring network are derived on the eigen-directions associated with the maximum eigen-values of the network stations. This study investigates how minimum detectable displacements in a GNSS monitoring network change depending on the accuracies of the network stations. For this, CORS-TR network in Turkey with 15 stations (a station fixed) is used. The data with 4h, 6h, 12 h and 24 h observing session duration in three sequential days of 2011, 2012 and 2013 were analyzed with Bernese 5.2 GNSS software. The repeatabilities of the daily solutions belonging to each year were analyzed carefully to scale the Bernese cofactor matrices properly. The root mean square (RMS) values for daily repeatability with respect to the combined 3-day solution are computed (the RMS values are generally less than 2 mm in the horizontal directions (north and east) and < 5 mm in the vertical direction for 24 h observing session duration). With the obtained cofactor matrices for these observing sessions, the minimum detectable displacements along the (maximum) eigen directions are compared each other. According to these comparisons, more session duration less minimum detectable

  1. Effect of displaced versus non-displaced pelvic fractures on long-term racing performance in 31 Thoroughbred racehorses.

    Science.gov (United States)

    Hennessy, S E; Muurlink, M A; Anderson, G A; Puksmann, T N; Whitton, R C

    2013-06-01

    To evaluate the long-term racing prognosis for Thoroughbred racehorses with displaced versus non-displaced fractures of the pelvis identified by scintigraphy. Retrospective case analysis. Medical records of 31 Thoroughbred racehorses presenting to the University of Melbourne Equine Centre with fractures of the pelvis that were identified by scintigraphy were reviewed. Pelvic fracture site was determined and defined as displaced or non-displaced based on ultrasound and/or radiographic findings. Race records were analysed for each horse, with a minimum of 24 months' follow-up, and correlated with fracture type to determine long-term prognosis for racing. Results are expressed as median and range. Fractures at a single site were more common (n = 22) than fractures involving two sites (n = 9) and the ilial wing was the most commonly affected (n = 12). Thoroughbred racehorses with displaced pelvic fractures at any site (n = 12) raced fewer times within 24 months of diagnosis than horses with non-displaced fractures (n = 19) (median 0.5, range 0-13 vs 7, 0-24; P = 0.037), but there was no clear statistical difference in race earnings between the two groups (median A$0, range A$0-$123,250 vs A$14,440, A$0-$325,500, respectively; P = 0.080). Four horses with displaced fractures (33%) were euthanased on humane grounds because of persistent severe pain. When these horses were excluded from the analysis, there were no differences in performance variables between horses with a displaced or non-displaced pelvic fracture. Thoroughbred racehorses with a displaced or non-displaced pelvic fracture that survive the initial post-injury period have a good prognosis for racing. © 2013 The Authors. Australian Veterinary Journal © 2013 Australian Veterinary Association.

  2. Prediction of ground surface displacement caused by grouting

    Institute of Scientific and Technical Information of China (English)

    郭风琪; 刘晓潭; 童无期; 单智

    2015-01-01

    Ground surface displacement caused by grouting was calculated with stochastic medium theory. Ground surface displacement was assumed to be caused by the cavity expansion of grouting, slurry seepage, and slurry contraction. A prediction method of ground surface displacement was developed. The reliability of the presented method was validated through a comparison between theoretical results and results from engineering practice. Results show that the present method is effective. The effect of parameters on uplift displacement was illustrated under different grouting conditions. Through analysis, it can be known that the ground surface uplift is mainly caused by osmosis of slurry and the primary influence angle of stratum βdetermines the influence range of surface uplift. Besides, the results show that ground surface uplift displacement decreases notably with increasing depth of the grouting cavity but it increases with increasing diffusion radius of grout and increasing grouting pressure.

  3. Evolution of displacements and strains in sheared amorphous solids

    Energy Technology Data Exchange (ETDEWEB)

    Maloney, Craig E [Department of Civil and Environmental Engineering, Carnegie Mellon University, Pittsburgh, PA (United States); Robbins, Mark O [Department of Physics and Astronomy, The Johns Hopkins University, Baltimore, MD (United States)], E-mail: craigmaloney@cmu.edu, E-mail: mr@pha.jhu.edu

    2008-06-18

    The local deformation of two-dimensional Lennard-Jones glasses under imposed shear strain is studied via computer simulations. Both the mean squared displacement and mean squared strain rise linearly with the length of the strain interval {delta}{gamma} over which they are measured. However, the increase in displacement does not represent single-particle diffusion. There are long-range spatial correlations in displacement associated with slip lines with an amplitude of order the particle size. Strong dependence on system size is also observed. The probability distributions of displacement and strain are very different. For small {delta}{gamma} the distribution of displacement has a plateau followed by an exponential tail. The distribution becomes Gaussian as {delta}{gamma} increases to about 0.03. The strain distributions consist of sharp central peaks associated with elastic regions, and long exponential tails associated with plastic regions. The latter persist to the largest {delta}{gamma} studied.

  4. Human response to ductless personalized ventilation coupled with displacement ventilation

    DEFF Research Database (Denmark)

    Dalewski, Mariusz; Veselý, Michal; Melikov, Arsen K.

    2012-01-01

    A human subject experiment was carried out to investigate the extent to which ductless personalized ventilation (DPV) in conjunction with displacement ventilation can improve perceived air quality (PAQ) and thermal comfort at elevated room air temperature in comparison with displacement ventilation...... alone. The experimental conditions comprised displacement ventilation alone (room air temperature of 23 °C, 26 °C, 29 °C) and DPV with displacement ventilation (26 °C, 29 °C), both operating at supply air temperatures 3, 5 or 6K lower than room air temperature, as well as mixing ventilation (23 °C, 3 K......). During one hour exposure participants answered questionnaires regarding PAQ and thermal comfort. PAQ was significantly better with DPV than without DPV at the same background conditions. Thermal comfort improved when DPV was used. Combining DPV with displacement ventilation showed the potential...

  5. [Displacement and tissue remodeling of temporomandibular joint disc].

    Science.gov (United States)

    Wang, M Q

    2017-03-09

    Sounding takes the highest prevalence of the signs of temporomandibular disorders (TMD). The well accepted theory of the mechanism for temporomandibular joint (TMJ) sounding is the internal derangement typically characterized by disc displacement. However, according to literature, there are approximately one third of asymptomatic joints in population had disc displacement, and, on the other hand, there are one fourth of TMJ sounding patients had not signs or very limited signs of disc displacement. Replacing the displaced disc to the normal position via methods like surgical operation did not achieve satisfactory long-term outcomes. In this review, we discuss and analyze the possible remodeling of the joint disc displacement diagnosed with imaging based on the anatomy and pathophysiology.

  6. Programmable energy landscapes for kinetic control of DNA strand displacement.

    Science.gov (United States)

    Machinek, Robert R F; Ouldridge, Thomas E; Haley, Natalie E C; Bath, Jonathan; Turberfield, Andrew J

    2014-11-10

    DNA is used to construct synthetic systems that sense, actuate, move and compute. The operation of many dynamic DNA devices depends on toehold-mediated strand displacement, by which one DNA strand displaces another from a duplex. Kinetic control of strand displacement is particularly important in autonomous molecular machinery and molecular computation, in which non-equilibrium systems are controlled through rates of competing processes. Here, we introduce a new method based on the creation of mismatched base pairs as kinetic barriers to strand displacement. Reaction rate constants can be tuned across three orders of magnitude by altering the position of such a defect without significantly changing the stabilities of reactants or products. By modelling reaction free-energy landscapes, we explore the mechanistic basis of this control mechanism. We also demonstrate that oxDNA, a coarse-grained model of DNA, is capable of accurately predicting and explaining the impact of mismatches on displacement kinetics.

  7. Land Restitution and Prevention of Forced Displacement in Colombia

    Directory of Open Access Journals (Sweden)

    Felipe Gómez-Isa

    2010-11-01

    Full Text Available The armed conflict in Colombia, which has generated over three million internally displaced persons, has dramatic humanitarian consequences and raises serious issues regarding the protection of displaced peoples’ rights. The underlying reasons for the displacement often lie in the dynamics associated with territorial control and land seizures undertaken for strategic, military or purely economic purposes. Domestic and international legal provisions have established the victims’ right to the restitution of their homes and property as the “preferred remedy” in cases of displacement. However, policies dealing with displacement, both those of the Colombian government and of several international institutions, fail to take this sufficiently into account. A comprehensive reparation policy for victims must necessarily entail the reversion of lands, territories and goods seized in Colombia under the pretext of the internal armed conflict.

  8. Displacement of maxillary third molar into the lateral pharyngeal space.

    Science.gov (United States)

    Lee, Doksa; Ishii, Syoichiro; Yakushiji, Noboru

    2013-10-01

    Iatrogenic tooth displacement is a rare complication during extraction of impacted molars, but displacement of a maxillary third molar into the maxillary sinus, infratemporal fossa, buccal space, pterygomandibular space, and lateral pharyngeal space has been reported. Currently, 6 published reports describe third molar displacement into the lateral pharyngeal space, only 1 of which involved the loss of a maxillary third molar into this area, which occurred after an attempted self-extraction by the patient. There have been no reported cases of iatrogenic displacement of the maxillary third molar during an extraction procedure. This article describes the recovery, under general anesthesia, of a maxillary third molar from the lateral pharyngeal space after an iatrogenic displacement.

  9. Using pressure and volumetric approaches to estimate CO2 storage capacity in deep saline aquifers

    OpenAIRE

    Thibeau, S.; Bachu, S.; Birkholzer, J.; Holloway, S; Neele, F.P.; Zou, Q

    2014-01-01

    Various approaches are used to evaluate the capacity of saline aquifers to store CO2, resulting in a wide range of capacity estimates for a given aquifer. The two approaches most used are the volumetric “open aquifer” and “closed aquifer” approaches. We present four full-scale aquifer cases, where CO2 storage capacity is evaluated both volumetrically (with “open” and/or “closed” approaches) and through flow modeling. These examples show that the “open aquifer” CO2 storage capacity estimation ...

  10. Effects of volumetric allocation on heave response of semisubmersible in deep sea

    Institute of Scientific and Technical Information of China (English)

    2009-01-01

    The configuration of semisubmersibles consisting of pontoons and columns and their corresponding heave motion response in incident progressive waves are examined. The purpose of the present study is to provide a theoretical approach to estimating the effects of volumetric allocation on natural period and response amplitude operator (RAO) in heave motion. We conclude that the amplitude of heave motion response can be considerably suppressed by appropriately adjusting volumetric allocation so that the natural heave period keeps away from the range of wave energy. The theoretical formulae are found in good agreement with the corresponding computational results by WAMIT.

  11. Volumetric Diffuse Optical Tomography for Small Animals Using a CCD-Camera-Based Imaging System

    Directory of Open Access Journals (Sweden)

    Zi-Jing Lin

    2012-01-01

    Full Text Available We report the feasibility of three-dimensional (3D volumetric diffuse optical tomography for small animal imaging by using a CCD-camera-based imaging system with a newly developed depth compensation algorithm (DCA. Our computer simulations and laboratory phantom studies have demonstrated that the combination of a CCD camera and DCA can significantly improve the accuracy in depth localization and lead to reconstruction of 3D volumetric images. This approach may present great interests for noninvasive 3D localization of an anomaly hidden in tissue, such as a tumor or a stroke lesion, for preclinical small animal models.

  12. DIRECT VOXEL-PROJECTION FOR VOLUMETRIC DATA RENDERING IN MEDICAL IMAGERY

    Institute of Scientific and Technical Information of China (English)

    吕忆松; 陈亚珠; 郭玉红

    2002-01-01

    The volumetric rendering of 3-D medical image data is very effective method for communication about radiological studies to clinicians. Algorithms that produce images with artifacts and inaccuracies are not clinically useful. This paper proposed a direct voxel-projection algorithm to implement volumetric data rendering. Using this algorithm, arbitrary volume rotation, transparent and cutaway views are generated satisfactorily. Compared with the existing raytracing methods, it improves the projection image quality greatly. Some experimental results about real medical CT image data demonstrate the advantages and fidelity of the proposed algorithm.

  13. CVN 68 Class Displacement Concerns; Dealing with the Differences between the Modeled and Actual Displacements

    Science.gov (United States)

    2009-09-01

    It is the second case that is most important for a ship in the water. It has been referred to as a special case of Archimedes ’ Principle , or the...from the bottom of the block to the waterline. Figure 6. Wooden block in water As described above using Archimedes ’ Principle , the weight of the...carrier. Archimedes ’ Law was discussed, as well as how this principle is applied to the displacement of an object in a body of water. The application

  14. Inter-fractional Target Displacement in the Prostate Image-Guided Radiotherapy using Cone Beam Computed Tomography

    Energy Technology Data Exchange (ETDEWEB)

    Dong, Kap Sang; Back, Chang Wook; Jeong, Yun Jeong; Bae, Jae Beom; Choi, Young Eun; Sung, Ki Hoon [Dept. of Radiation Oncology, Gachon University Gil Medical Center, Incheon (Korea, Republic of)

    2016-12-15

    To quantify the inter-fractional variation in prostate displacement and their dosimetric effects for prostate cancer treatment. A total of 176 daily cone-beam CT (CBCT) sets acquired for 6 prostate cancer patients treated with volumetric-modulated arc therapy (VMAT) were retrospectively reviewed. For each patient, the planning CT (pCT) was registered to each daily CBCT by aligning the bony anatomy. The prostate, rectum, and bladder were delineated on daily CBCT, and the contours of these organs in the pCT were copied to the daily CBCT. The concordance of prostate displacement, deformation, and size variation between pCT and daily CBCT was evaluated using the Dice similarity coefficient (DSC). The mean volume of prostate was 37.2 cm3 in the initial pCT, and the variation was around ±5% during the entire course of treatment for all patients. The mean DSC was 89.9%, ranging from 70% to 100% for prostate displacement. Although the volume change of bladder and rectum per treatment fraction did not show any correlation with the value of DSC (r=-0.084, p=0.268 and r=-0.162, p=0.032, respectively), a decrease in the DSC value was observed with increasing volume change of the bladder and rectum (r=-0.230,p=0.049 and r=-0.240,p=0.020, respectively). Consistency of the volume of the bladder and rectum cannot guarantee the accuracy of the treatment. Our results suggest that patient setup with the registration between the pCT and daily CBCT should be considered aligning soft tissue.

  15. Determining Fault Geometries From Surface Displacements

    Science.gov (United States)

    Volkov, D.; Voisin, C.; Ionescu, I. R.

    2017-02-01

    We introduce a new algorithm for determining the geometry of active parts of faults. This algorithm uses surface measurements of displacement fields and local modeling of the Earth's crust as a half-space elastic medium. The numerical method relies on iterations alternating non-linear steps for recovering the geometry and linear steps for reconstructing slip fields. Our algorithm greatly improves upon past attempts at reconstructing fault profiles. We argue that these past attempts suffered from either the restrictive assumption that the geometry of faults can be derived using only uniformly constant slips or that they relied on arbitrary assumptions on the statistics of the reconstruction error. We test this algorithm on the 2006 Guerrero, Mexico, slow slip event (SSE) and on the 2009 SSE for the same region. These events occurred on a relatively well-known subduction zone, whose geometry was derived from seismicity and gravimetric techniques, see Kostoglodov et al. (Geophys Res Lett 23(23):3385-3388, 1996), Pardo and Suarez (J Geophys Res 100(B7):357-373, 1995), Singh and Pardo (Geophys Res Lett 20(14):1483-1486, 1993), so our results can be compared to known benchmarks. Our derived geometry is found to be consistent with these benchmarks regarding dip and strike angles and the positioning of the North American Trench. In addition, our derived slip distribution is also consistent with previous studies (all done with an assumed fixed geometry), see Larson et al. (Geophys Res Lett 34(13), 2007), Bekaert et al. (J Geophys Res: Solid Earth 120(2):1357-1375, 2015), Radiguet et al. (Geophys J Int 184(2):816-828, 2011, J Geophys Res 2012), Rivet et al. (Geophys Res Lett 38(8), 2011), Vergnolle et al. (J Geophys Res: Solid Earth 115(B8), 2010), Walpersdorf et al. Geophys Res Lett 38(15), 2011), to name a few. We believe that the new computational inverse method introduced in this paper holds great promise for applications to blind inversion cases, where both geometry and

  16. Correlation Between Liver Volumetric Computed Tomography Results and Measured Liver Weight: A Tool for Preoperative Planning of Liver Transplant

    NARCIS (Netherlands)

    Sonnemans, L.J.; Hol, J.C.; Monshouwer, R.; Prokop, M.; Klein, W.M.

    2016-01-01

    OBJECTIVES: Before liver transplant, it is necessary to know the size of the organ in advance of the procedure. We studied the correlation between liver volumetric computed tomography results and liver weight. MATERIALS AND METHODS: Postmortem volumetric computed tomography was conducted on cadavers

  17. The role of environmental degradation in population displacement.

    Science.gov (United States)

    Lonergan, S

    1998-01-01

    This article answers a series of questions about the role of environmental degradation in population displacement, refugee movement, and migration. The environment tends not to be included in the reasons for migration. Roger's indicators of migration potential include population growth, economic restructuring, increased economic disparities, and increased refugee flows. Myers (1993) estimated that international displacement and internal displacement may amount to about 25 million and may rise to 150 million by 2050. The role of the environment in displacement must be examined in the broader political and cultural context. Definitions of environmental refugees are ambiguous and inconsistent, and research has not answered why people continue to move to Mexico City and Chongqing, China, which both have very high levels of pollution. El-Hinnawi (1985) defined 3 groups of environmental refugees: those displaced due to natural disasters; those displaced due to permanent habitat changes; and those displaced who migrated from areas that cannot support their basic needs and who desire an improved quality of life. Lonergan (1994) identified environmental stresses as natural disasters, cumulative or slow-onset changes, accidental disruptions or industrial accidents, development projects, and conflict and warfare. These 5 causes must be treated separately and not lumped together as environmental degradation. Shoreline erosion, coastal flooding, and agricultural disruption associated with climate change may increase migration. Global measures must address world poverty and promote sustainable development.

  18. Passive resistance increases differentially in various jaw displacement directions.

    Science.gov (United States)

    Hansma, H J; Langenbach, G E J; Koolstra, J H; Van Eijden, T M G J

    2006-08-01

    In the present study, the passive resistance of the human jaw system was quantified in relation to the three-dimensional jaw displacement and the Posselt-envelope, using both in vivo measurements and computer simulation. In eight subjects, the jaw was passively displaced with a step-wise increasing force in three orthogonal directions. Muscle relaxation was monitored using electromyography (EMG) with visual feedback. A biomechanical model of an average human system was used to examine the contributions of the jaw muscles. The largest excursion was found for the vertical direction. Protrusive and lateral directions were more restricted. In protrusive and lateral directions, the jaw could generally move beyond the Posselt-envelope. The stiffness of the jaw increased with proceeding jaw displacement in all directions. The stiffness was larger in the protrusive direction than in the vertical and lateral directions. The model's predictions of stiffness were comparable to the in vivo measurements. However, in protrusive direction, the maximum jaw displacement was larger than in vivo. The estimated passive muscle forces showed that vertical displacement was mainly restricted by the complete group of closing muscles, while protrusive and lateral jaw displacement was restricted by selective individual muscles. The human jaw system has larger motion range in the protrusive and lateral directions than can be exploited by active muscle use. Stiffness of jaw displacement is higher in the protrusive direction compared to the vertical and lateral directions.

  19. Wide-range displacement expressions for standard fracture mechanics specimens

    Science.gov (United States)

    Kapp, J. A.; Gross, B.; Leger, G. S.

    1985-01-01

    Wide-range algebraic expressions for the displacement of cracked fracture mechanics specimens are developed. For each specimen two equations are given: one for the displacement as a function of crack length, the other for crack length as a function of displacement. All the specimens that appear in ASTM Test for Plane-Strain Fracture Toughness of Metallic Materials (E 399) are represented in addition to the crack mouth displacement for a pure bending specimen. For the compact tension sample and the disk-shaped compact tension sample, the displacement at the crack mouth and at the load line are both considered. Only the crack mouth displacements for the arc-shaped tension samples are presented. The agreement between the displacements or crack lengths predicted by the various equations and the corresponding numerical data from which they were developed are nominally about 3 percent or better. These expressions should be useful in all types of fracture testing including fracture toughness, K-resistance, and fatigue crack growth.

  20. Development of a Wireless Displacement Measurement System Using Acceleration Responses

    Directory of Open Access Journals (Sweden)

    Billie F. Spencer Jr.

    2013-07-01

    Full Text Available Displacement measurements are useful information for various engineering applications such as structural health monitoring (SHM, earthquake engineering and system identification. Most existing displacement measurement methods are costly, labor-intensive, and have difficulties particularly when applying to full-scale civil structures because the methods require stationary reference points. Indirect estimation methods converting acceleration to displacement can be a good alternative as acceleration transducers are generally cost-effective, easy to install, and have low noise. However, the application of acceleration-based methods to full-scale civil structures such as long span bridges is challenging due to the need to install cables to connect the sensors to a base station. This article proposes a low-cost wireless displacement measurement system using acceleration. Developed with smart sensors that are low-cost, wireless, and capable of on-board computation, the wireless displacement measurement system has significant potential to impact many applications that need displacement information at multiple locations of a structure. The system implements an FIR-filter type displacement estimation algorithm that can remove low frequency drifts typically caused by numerical integration of discrete acceleration signals. To verify the accuracy and feasibility of the proposed system, laboratory tests are carried out using a shaking table and on a three storey shear building model, experimentally confirming the effectiveness of the proposed system.

  1. Two conceptual models of displacement transfer and examples

    Institute of Scientific and Technical Information of China (English)

    GUAN; Shuwei; WANG; Xin; YANG; Shufeng; HE; Dengfa; ZHAO; W

    2005-01-01

    This paper presents two conceptual models of displacement transfer, reverse symmetry model and infinitely equal division model, based on the fault-bend folding theory. If the fault shape is held constant in the trend, then the distribution of slip magnitude, geometry of imbricate structures and its axial surface map all display reverse symmetry on the process of displacement transfer, as called reverse symmetry model in this paper. However, if the ramp height of thrust fault decreases gradually along its strike, the displacement is postulated to be equally and infinitely divided to every thrust that is formed subsequently, this kinematic process is described using infinitely equal division model. In both models, displacement transfer is characterized by the regular changes of imbricate thrusting in the trend. Geometric analysis indicates that the displacement transfer grads can be estimated using the tangent of deflective angle of hinterland structures. Displacement transfer is often responsible for the distortion and branching of the surface anticlines, especially in the region where the multi-level detachment structures is developed. We also present some examples from the frontal structures of the Southern Tianshan fold-and-thrust belt, Xinjiang, China. Displacement transfer between deep imbricate thrusts in the middle segment of Qiulitag anticline zone causes the Kuqatawu and Southern Qiulitag deep anticlines left-lateral echelon. The region, where these two deep anticlines overlap, is characterized by duplex structures, and extends about 18 km. The shallow anticline is migrated southward displaying obvious "S" form in this area.

  2. Two-dimensional and volumetric airway changes after bimaxillary surgery for class III malocclusion.

    Science.gov (United States)

    Vaezi, Toraj; Zarch, Seyed Hossein Hosseini; Eshghpour, Majid; Kermani, Hamed

    2017-04-01

    Any change in maxilla and mandible position can alter the upper airway, and any decrease in the upper airway can cause sleep disorders. Thus, it is necessary to assess airway changes after repositioning of the maxilla and mandible during orthognathic surgery. The purpose of this study was to evaluate linear and volumetric changes in the upper airway after bimaxillary surgery to correct class III malocclusion via cone-beam computed tomography (CBCT) and to identify correlations between linear and volumetric changes. This was a prospective cohort study. CBCTs from 10 class III patients were evaluated before surgery and three months after. The Wilcoxon one-sample test was used to evaluate the differences in measurements before and after surgery. Spearman's rank correlation coefficient was used to test the correlation between linear and volumetric changes. The results show that the nasopharyngeal space increased significantly, and that this increase correlated with degree of maxillary advancement. No significant changes were found in volumes before and after surgery. A correlation was found between linear and volumetric oropharyngeal changes. Bimaxillary surgical correction of class III malocclusion did not cause statistically significant changes in the posterior airway space.

  3. MATHEMATICAL MODEL FOR DETERMINATION OF VOLUMETRIC OUTPUT OF LUMBER FROM LOGS, CONTAINING SEVERAL QUALITY AREAS

    Directory of Open Access Journals (Sweden)

    Mikryukova E. V.

    2014-12-01

    Full Text Available In the article we present a method of cutting logs, containing several quality areas. For this method, a mathematical model was developed to determine the volumetric output of lumber, which allows to determine the geometric dimensions of the lumber cut from the different quality areas separated concentric circles, depending on size and quality characteristics of logs

  4. Trapping volumetric measurement by multidetector CT in chronic obstructive pulmonary disease: Effect of CT threshold

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Xiaohua; Yuan, Huishu [Department of Radiology, Peking University Third Hospital, Beijing 100191 (China); Duan, Jianghui [Medical School, Peking University, Beijing 100191 (China); Du, Yipeng; Shen, Ning; He, Bei [Department of Respiration Internal Medicine, Peking University Third Hospital, Beijing 100191 (China)

    2013-08-15

    Purpose: The purpose of this study was to evaluate the effect of various computed tomography (CT) thresholds on trapping volumetric measurements by multidetector CT in chronic obstructive pulmonary disease (COPD).Methods: Twenty-three COPD patients were scanned with a 64-slice CT scanner in both the inspiratory and expiratory phase. CT thresholds of −950 Hu in inspiration and −950 to −890 Hu in expiration were used, after which trapping volumetric measurements were made using computer software. Trapping volume percentage (Vtrap%) under the different CT thresholds in the expiratory phase and below −950 Hu in the inspiratory phase was compared and correlated with lung function.Results: Mean Vtrap% was similar under −930 Hu in the expiratory phase and below −950 Hu in the inspiratory phase, being 13.18 ± 9.66 and 13.95 ± 6.72 (both lungs), respectively; this difference was not significant (P= 0.240). Vtrap% under −950 Hu in the inspiratory phase and below the −950 to −890 Hu threshold in the expiratory phase was moderately negatively correlated with the ratio of forced expiratory volume in one second to forced vital capacity and the measured value of forced expiratory volume in one second as a percentage of the predicted value.Conclusions: Trapping volumetric measurement with multidetector CT is a promising method for the quantification of COPD. It is important to know the effect of various CT thresholds on trapping volumetric measurements.

  5. Transplantation and Perfusion of Microvascular Fragments in a Rodent Model of Volumetric Muscle Loss Injury

    Science.gov (United States)

    2014-07-01

    options are available for the treatment of volumetric muscle loss (VML). An important consideration that needs to be addressed for the development ...fibroblasts that underwent vascular and myogenic development in vitro resulted in substantial tissue perfusion when implanted in an abdominal defect...Greene AS (2000) Development of an implantable muscle stimulator: measurement of stimulated angiogenesis and poststimulus vessel regression

  6. Optical Addressing of Multi-Colour Photochromic Material Mixture for Volumetric Display

    Science.gov (United States)

    Hirayama, Ryuji; Shiraki, Atsushi; Naruse, Makoto; Nakamura, Shinichiro; Nakayama, Hirotaka; Kakue, Takashi; Shimobaba, Tomoyoshi; Ito, Tomoyoshi

    2016-08-01

    This is the first study to demonstrate that colour transformations in the volume of a photochromic material (PM) are induced at the intersections of two control light channels, one controlling PM colouration and the other controlling decolouration. Thus, PM colouration is induced by position selectivity, and therefore, a dynamic volumetric display may be realised using these two control lights. Moreover, a mixture of multiple PM types with different absorption properties exhibits different colours depending on the control light spectrum. Particularly, the spectrum management of the control light allows colour-selective colouration besides position selectivity. Therefore, a PM-based, full-colour volumetric display is realised. We experimentally construct a mixture of two PM types and validate the operating principles of such a volumetric display system. Our system is constructed simply by mixing multiple PM types; therefore, the display hardware structure is extremely simple, and the minimum size of a volume element can be as small as the size of a molecule. Volumetric displays can provide natural three-dimensional (3D) perception; therefore, the potential uses of our system include high-definition 3D visualisation for medical applications, architectural design, human–computer interactions, advertising, and entertainment.

  7. VOLUMETRIC METHOD FOR EVALUATION OF BEACHES VARIABILITY BASED ON GIS-TOOLS

    Directory of Open Access Journals (Sweden)

    V. V. Dolotov

    2015-01-01

    Full Text Available In frame of cadastral beach evaluation the volumetric method of natural variability index is proposed. It base on spatial calculations with Cut-Fill method and volume accounting ofboththe common beach contour and specific areas for the each time.

  8. Using pressure and volumetric approaches to estimate CO2 storage capacity in deep saline aquifers

    NARCIS (Netherlands)

    Thibeau, S.; Bachu, S.; Birkholzer, J.; Holloway, S.; Neele, F.P.; Zou, Q.

    2014-01-01

    Various approaches are used to evaluate the capacity of saline aquifers to store CO2, resulting in a wide range of capacity estimates for a given aquifer. The two approaches most used are the volumetric “open aquifer” and “closed aquifer” approaches. We present four full-scale aquifer cases, where C

  9. Exploration of volumetric cerebral changes, with de micro-MRi, due to psychomotor exercise in mice

    OpenAIRE

    Moës, Florian; Plenevaux, Alain; Becker, Guillaume; Tirelli, Ezio; Lespine, Louis-Ferdinand

    2015-01-01

    It's well know that exercise is good for health .In addition exercise has postive effects on cognition ,neurodegenerative disease and on mood. Some studies show that exercise has effect on brain so the aim of this study is to see if there are volumetric changes due to exercise or not.

  10. Effect of compression paddle tilt correction on volumetric breast density estimation.

    Science.gov (United States)

    Kallenberg, Michiel G J; van Gils, Carla H; Lokate, Mariëtte; den Heeten, Gerard J; Karssemeijer, Nico

    2012-08-21

    For the acquisition of a mammogram, a breast is compressed between a compression paddle and a support table. When compression is applied with a flexible compression paddle, the upper plate may be tilted, which results in variation in breast thickness from the chest wall to the breast margin. Paddle tilt has been recognized as a major problem in volumetric breast density estimation methods. In previous work, we developed a fully automatic method to correct the image for the effect of compression paddle tilt. In this study, we investigated in three experiments the effect of paddle tilt and its correction on volumetric breast density estimation. Results showed that paddle tilt considerably affected accuracy of volumetric breast density estimation, but that effect could be reduced by tilt correction. By applying tilt correction, a significant increase in correspondence between mammographic density estimates and measurements on MRI was established. We argue that in volumetric breast density estimation, tilt correction is both feasible and essential when mammographic images are acquired with a flexible compression paddle.

  11. Follow-up after gamma knife radiosurgery for vestibular schwannomas: volumetric and axial control rates

    NARCIS (Netherlands)

    Timmer, F.C.A.; Hanssens, P.E.; Haren, A.E. van; Overbeeke, J.J. van; Mulder, J.J.S.; Cremers, C.W.R.J.; Graamans, K.

    2011-01-01

    OBJECTIVES/HYPOTHESIS: A prospective long-term follow-up study was conducted to evaluate the results of gamma knife radiosurgery (GKRS) for vestibular schwannoma (VS) patients. Both axial and volumetric measurements are used to determine tumor size during follow-up. STUDY DESIGN: Individual prospect

  12. Empirical correlation of volumetric mass transfer coefficient for a rectangular internal-loop airlift bioreactor

    Science.gov (United States)

    An empirical correlation of volumetric mass transfer coefficient was developed for a pilot scale internal-loop rectangular airlift bioreactor that was designed for biotechnology. The empirical correlation combines classic turbulence theory, Kolmogorov’s isotropic turbulence theory with Higbie’s pen...

  13. Accelerated partial breast irradiation (APBI): are breath-hold and volumetric radiation therapy techniques useful?

    NARCIS (Netherlands)

    Essers, M.; Osman, S.O.; Hol, S.; Donkers, T.; Poortmans, P.M.P.

    2014-01-01

    BACKGROUND: In a selective group of patients accelerated partial breast irradiation (APBI) might be applied after conservative breast surgery to reduce the amount of irradiated healthy tissue. The role of volumetric modulated arc therapy (VMAT) and voluntary moderately deep inspiration breath-hold (

  14. The NCS code of practice for the quality assurance and control for volumetric modulated arc therapy

    NARCIS (Netherlands)

    Mans, Anton; Schuring, Danny; Arends, Mark P.; Vugts, Cornelia A. J. M.; Wolthaus, Jochem W. H.; Lotz, Heidi T.; Admiraal, Marjan; Louwe, Rob J. W.; Ollers, Michel C.; van de Kamer, Jeroen B.

    2016-01-01

    In 2010, the NCS (Netherlands Commission on Radiation Dosimetry) installed a subcommittee to develop guidelines for quality assurance and control for volumetric modulated arc therapy (VMAT) treatments. The report (published in 2015) has been written by Dutch medical physicists and has therefore, ine

  15. Development, Construction, and Operation of a Multisample Volumetric Apparatus for the Study of Gas Adsorption Equilibrium

    Science.gov (United States)

    Ribeiro, Rui P. P. L.; Silva, Ricardo J. S.; Esteves, Isabel A. A. C.; Mota, Jose´ P. B.

    2015-01-01

    The construction of a simple volumetric adsorption apparatus is highlighted. The setup is inexpensive and provides a clear demonstration of gas phase adsorption concepts. The topic is suitable for undergraduate chemistry and chemical engineering students. Moreover, this unit can also provide quantitative data that can be used by young researchers…

  16. Real-time volumetric deformable models for surgery simulation using finite elements and condensation

    DEFF Research Database (Denmark)

    Bro-Nielsen, Morten; Cotin, S.

    1996-01-01

    This paper discusses the application of SD solid volumetric Finite Element models to surgery simulation. In particular it introduces three new ideas for solving the problem of achieving real-time performance for these models. The simulation system we have developed is described and we demonstrate...

  17. Automated volumetric grid generation for finite element modeling of human hand joints

    Energy Technology Data Exchange (ETDEWEB)

    Hollerbach, K.; Underhill, K. [Lawrence Livermore National Lab., CA (United States); Rainsberger, R. [XYZ Scientific Applications, Inc., Livermore, CA (United States)

    1995-02-01

    We are developing techniques for finite element analysis of human joints. These techniques need to provide high quality results rapidly in order to be useful to a physician. The research presented here increases model quality and decreases user input time by automating the volumetric mesh generation step.

  18. Using pressure and volumetric approaches to estimate CO2 storage capacity in deep saline aquifers

    NARCIS (Netherlands)

    Thibeau, S.; Bachu, S.; Birkholzer, J.; Holloway, S.; Neele, F.P.; Zou, Q.

    2014-01-01

    Various approaches are used to evaluate the capacity of saline aquifers to store CO2, resulting in a wide range of capacity estimates for a given aquifer. The two approaches most used are the volumetric “open aquifer” and “closed aquifer” approaches. We present four full-scale aquifer cases, where

  19. Follow-up after gamma knife radiosurgery for vestibular schwannomas: volumetric and axial control rates

    NARCIS (Netherlands)

    Timmer, F.C.A.; Hanssens, P.E.; Haren, A.E. van; Overbeeke, J.J. van; Mulder, J.J.S.; Cremers, C.W.R.J.; Graamans, K.

    2011-01-01

    OBJECTIVES/HYPOTHESIS: A prospective long-term follow-up study was conducted to evaluate the results of gamma knife radiosurgery (GKRS) for vestibular schwannoma (VS) patients. Both axial and volumetric measurements are used to determine tumor size during follow-up. STUDY DESIGN: Individual

  20. Species-specific contribution of volumetric growth and tissue convergence to posterior body elongation in vertebrates.

    Science.gov (United States)

    Steventon, Ben; Duarte, Fernando; Lagadec, Ronan; Mazan, Sylvie; Nicolas, Jean-François; Hirsinger, Estelle

    2016-05-15

    Posterior body elongation is a widespread mechanism propelling the generation of the metazoan body plan. The posterior growth model predicts that a posterior growth zone generates sufficient tissue volume to elongate the posterior body. However, there are energy supply-related differences between vertebrates in the degree to which growth occurs concomitantly with embryogenesis. By applying a multi-scalar morphometric analysis in zebrafish embryos, we show that posterior body elongation is generated by an influx of cells from lateral regions, by convergence-extension of cells as they exit the tailbud, and finally by a late volumetric growth in the spinal cord and notochord. Importantly, the unsegmented region does not generate additional tissue volume. Fibroblast growth factor inhibition blocks tissue convergence rather than volumetric growth, showing that a conserved molecular mechanism can control convergent morphogenesis through different cell behaviours. Finally, via a comparative morphometric analysis in lamprey, dogfish, zebrafish and mouse, we propose that elongation via posterior volumetric growth is linked to increased energy supply and is associated with an overall increase in volumetric growth and elongation. © 2016. Published by The Company of Biologists Ltd.

  1. Cerebrospinal fluid volumetric MRI mapping as a simple measurement for evaluating brain atrophy

    NARCIS (Netherlands)

    De Vis, J B; Zwanenburg, J J|info:eu-repo/dai/nl/290473683; van der Kleij, L A; Spijkerman, J M; Biessels, G J|info:eu-repo/dai/nl/165576367; Hendrikse, J|info:eu-repo/dai/nl/266590268; Petersen, E T

    2016-01-01

    OBJECTIVES: To assess whether volumetric cerebrospinal fluid (CSF) MRI can be used as a surrogate for brain atrophy assessment and to evaluate how the T2 of the CSF relates to brain atrophy. METHODS: Twenty-eight subjects [mean age 64 (sd 2) years] were included; T1-weighted and CSF MRI were perform

  2. Ni foam cathode enables high volumetric H2 production in a microbial electrolysis cell

    NARCIS (Netherlands)

    Jeremiasse, A.W.; Hamelers, H.V.M.; Saakes, M.; Buisman, C.J.N.

    2010-01-01

    Valuable, “green” H2 can be produced with a microbial electrolysis cell (MEC). To achieve a high volumetric production rate of high purity H2, a continuous flow MEC with an anion exchange membrane, a flow through bioanode and a flow through Ni foam cathode was constructed. At an electrical energy in

  3. Semiautomated volumetric response evaluation as an imaging biomarker in superior sulcus tumors

    Energy Technology Data Exchange (ETDEWEB)

    Vos, C.G.; Paul, M.A. [VU University Medical Center, Departments of Surgery, Amsterdam (Netherlands); Dahele, M.; Soernsen de Koste, J.R. van; Senan, S. [VU University Medical Center, Departments of Radiation Oncology, Amsterdam (Netherlands); Bahce, I.; Smit, E.F. [VU University Medical Center, Departments of Pulmonary Diseases, Amsterdam (Netherlands); Thunnissen, E. [VU University Medical Center, Departments of Pathology, Amsterdam (Netherlands); Hartemink, K.J. [VU University Medical Center, Departments of Surgery, Amsterdam (Netherlands); Netherlands Cancer Institute - Antoni van Leeuwenhoek Hospital (NKI-AVL), Department of Surgery, Amsterdam (Netherlands)

    2014-02-15

    Volumetric response to therapy has been suggested as a biomarker for patient-centered outcomes. The primary aim of this pilot study was to investigate whether the volumetric response to induction chemoradiotherapy was associated with pathological complete response (pCR) or survival in patients with superior sulcus tumors managed with trimodality therapy. The secondary aim was to evaluate a semiautomated method for serial volume assessment. In this retrospective study, treatment outcomes were obtained from a departmental database. The tumor was delineated on the computed tomography (CT) scan used for radiotherapy planning, which was typically performed during the first cycle of chemotherapy. These contours were transferred to the post-chemoradiotherapy diagnostic CT scan using deformable image registration (DIR) with/without manual editing. CT scans from 30 eligible patients were analyzed. Median follow-up was 51 months. Neither absolute nor relative reduction in tumor volume following chemoradiotherapy correlated with pCR or 2-year survival. The tumor volumes determined by DIR alone and DIR + manual editing correlated to a high degree (R{sup 2} = 0.99, P < 0.01). Volumetric response to induction chemoradiotherapy was not correlated with pCR or survival in patients with superior sulcus tumors managed with trimodality therapy. DIR-based contour propagation merits further evaluation as a tool for serial volumetric assessment. (orig.)

  4. Toddlers with autism; metabolic, radiologic, and volumetric aspects of brain development

    NARCIS (Netherlands)

    Zeegers, M.

    2006-01-01

    The overall aim of this thesis is to study MR spectroscopic, radiologic, and volumetric brain correlates in very young children with severe developmental disorders; ASD, mental retardation, and language disorder. We wished to examine brain – behaviour relationships in children with ASD at a very you

  5. A hand-held row-column addressed CMUT probe with integrated electronics for volumetric imaging

    DEFF Research Database (Denmark)

    Engholm, Mathias; Christiansen, Thomas Lehrmann; Beers, Christopher;

    2015-01-01

    A 3 MHz, λ / 2-pitch 62+62 channel row-column addressed 2-D CMUT array designed to be mounted in a probe handle and connected to a commercial BK Medical scanner for real-time volumetric imaging is presented. It is mounted and wire-bonded on a flexible PCB, which is connected to two rigid PCBs wit...

  6. Real-time volumetric deformable models for surgery simulation using finite elements and condensation

    DEFF Research Database (Denmark)

    Bro-Nielsen, Morten; Cotin, S.

    1996-01-01

    This paper discusses the application of SD solid volumetric Finite Element models to surgery simulation. In particular it introduces three new ideas for solving the problem of achieving real-time performance for these models. The simulation system we have developed is described and we demonstrate...

  7. Progress in two-dimensional arrays for real-time volumetric imaging.

    Science.gov (United States)

    Light, E D; Davidsen, R E; Fiering, J O; Hruschka, T A; Smith, S W

    1998-01-01

    The design, fabrication, and evaluation of two dimensional array transducers for real-time volumetric imaging are described. The transducers we have previously described operated at frequencies below 3 MHz and were unwieldy to the operator because of the interconnect schemes used in connecting to the transducer handle. Several new transducers have been developed using new connection technology. A 40 x 40 = 1,600 element, 3.5 MHz array was fabricated with 256 transmit and 256 receive elements. A 60 x 60 = 3,600 element 5.0 MHz array was constructed with 248 transmit and 256 receive elements. An 80 x 80 = 6,400 element, 2.5 MHz array was fabricated with 256 transmit and 208receive elements. 2-D transducer arrays were also developed for volumetric scanning in an intra cardiac catheter, a 10 x 10 = 100 element 5.0 MHz forward-looking array and an 11 x 13 = 143 element 5.0 MHz side-scanning array. The-6dB fractional bandwidths for the different arrays varied from 50% to 63%, and the 50 omega insertion loss for all the transducers was about-64 dB. The transducers were used to generate real-time volumetric images in phantoms and in vivo using the Duke University real time volumetric imaging system, which is capable of generating multiple planes at any desired angle and depth within the pyramidal volume.

  8. Helium vs. Proton Induced Displacement Damage in Electronic Materials

    Science.gov (United States)

    Ringo, Sawnese; Barghouty, A. F.

    2010-01-01

    In this project, the specific effects of displacement damage due to the passage of protons and helium nuclei on some typical electronic materials will be evaluated and contrasted. As the electronic material absorbs the energetic proton and helium momentum, degradation of performance occurs, eventually leading to overall failure. Helium nuclei traveling at the same speed as protons are expected to impart more to the material displacement damage; due to the larger mass, and thus momentum, of helium nuclei compared to protons. Damage due to displacement of atoms in their crystalline structure can change the physical properties and hence performance of the electronic materials.

  9. Perceived Air Quality in a Displacement Ventilated Room

    DEFF Research Database (Denmark)

    Brohus, Henrik; Knudsen, Henrik Nellemose; Nielsen, Peter V.

    In a displacement ventilated room the non-uniform contaminant distribution causes an improved indoor air quality in the occupied zone compared with conventional mixing ventilation. This has been demonstrated in numerous studies by chemical measurements. In this study the air quality...... in a displacement ventilated room was determined directly by asking humans about how they perceived the air quality. A trained sensory panel comprising 12 subjects assessed the perceived air quality immediately after entering a climate chamber. The experiments showed that the perceived air quality...... in the displacement ventilated chamber was substantially better than in the case of mixing ventilation....

  10. Displacement fields denoising and strains extraction by finite element method

    Institute of Scientific and Technical Information of China (English)

    2011-01-01

    Optical full-field measurement methods are now widely applied in various domains. In general,the displacement fields can be directly obtained from the measurement,however in mechanical analysis strain fields are preferred.To extract strain fields from noisy displacement fields is always a challenging topic.In this study,a finite element method for smoothing displacement fields and calculating strain fields is proposed.An experimental test case on a holed aluminum specimen under tension is applied to vali...

  11. Serial forced displacement in American cities, 1916-2010.

    Science.gov (United States)

    Fullilove, Mindy Thompson; Wallace, Rodrick

    2011-06-01

    Serial forced displacement has been defined as the repetitive, coercive upheaval of groups. In this essay, we examine the history of serial forced displacement in American cities due to federal, state, and local government policies. We propose that serial forced displacement sets up a dynamic process that includes an increase in interpersonal and structural violence, an inability to react in a timely fashion to patterns of threat or opportunity, and a cycle of fragmentation as a result of the first two. We present the history of the policies as they affected one urban neighborhood, Pittsburgh's Hill District. We conclude by examining ways in which this problematic process might be addressed.

  12. Inhomogeneous phase shifting: an algorithm for nonconstant phase displacements

    Energy Technology Data Exchange (ETDEWEB)

    Tellez-Quinones, Alejandro; Malacara-Doblado, Daniel

    2010-11-10

    In this work, we have developed a different algorithm than the classical one on phase-shifting interferometry. These algorithms typically use constant or homogeneous phase displacements and they can be quite accurate and insensitive to detuning, taking appropriate weight factors in the formula to recover the wrapped phase. However, these algorithms have not been considered with variable or inhomogeneous displacements. We have generalized these formulas and obtained some expressions for an implementation with variable displacements and ways to get partially insensitive algorithms with respect to these arbitrary error shifts.

  13. Uncovering deformation processes from surface displacements

    Science.gov (United States)

    Stramondo, Salvatore

    2013-04-01

    The aim of this talk is to provide an overview about the most recent outcomes in Earth Sciences, describe the role of satellite remote sensing, together with GPS, ground measurement and further data, for geophysical parameter retrieval in well known case studies where the combined approach dealing with the use of two or more techniques/datasets have demonstrated their effectiveness. The Earth Sciences have today a wide availability of instruments and sensors able to provide scientists with an unprecedented capability to study the physical processes driving earthquakes, volcanic eruptions, landslides, and other dynamic Earth systems. Indeed measurements from satellites allow systematic observation of the Earth surface covering large areas, over a long time period and characterized by growing sample intervals. Interferometric Synthetic Aperture Radar (InSAR) technique has demonstrated its effectiveness to investigate processes responsible for crustal faulting stemming from the detection of surface deformation patterns. Indeed using satellite data along ascending and descending orbits, as well as different incident angles, it is possible in principle to retrieve the full 3D character of the ground motion. To such aim the use of GPS stations providing 3D displacement components is a reliable complementary instrument. Finally, offset tracking techniques and Multiple Aperture Interferometry (MAI) may provide a contribution to the analysis of horizontal and NS deformation vectors. The estimation of geophysical parameters using InSAR has been widely discussed in seismology and volcanology, and also applied to deformation associated with groundwater and other subsurface fluids. These applications often involve the solution of an inverse problem, which means the retrieval of optimal source parameters at depth for volcanoes and earthquakes, from the knowledge of surface deformation from InSAR. In recent years, InSAR measurements combined with traditional seismological and

  14. Effects of Different Reconstruction Parameters on CT Volumetric Measurement 
of Pulmonary Nodules

    Directory of Open Access Journals (Sweden)

    Rongrong YANG

    2012-02-01

    Full Text Available Background and objective It has been proven that volumetric measurements could detect subtle changes in small pulmonary nodules in serial CT scans, and thus may play an important role in the follow-up of indeterminate pulmonary nodules and in differentiating malignant nodules from benign nodules. The current study aims to evaluate the effects of different reconstruction parameters on the volumetric measurements of pulmonary nodules in chest CT scans. Methods Thirty subjects who underwent chest CT scan because of indeterminate pulmonary nodules in General Hospital of Tianjin Medical University from December 2009 to August 2011 were retrospectively analyzed. A total of 52 pulmonary nodules were included, and all CT data were reconstructed using three reconstruction algorithms and three slice thicknesses. The volumetric measurements of the nodules were performed using the advanced lung analysis (ALA software. The effects of the reconstruction algorithms, slice thicknesses, and nodule diameters on the volumetric measurements were assessed using the multivariate analysis of variance for repeated measures, the correlation analysis, and the Bland-Altman method. Results The reconstruction algorithms (F=13.6, P<0.001 and slice thicknesses (F=4.4, P=0.02 had significant effects on the measured volume of pulmonary nodules. In addition, the coefficients of variation of nine measurements were inversely related with nodule diameter (r=-0.814, P<0.001. The volume measured at the 2.5 mm slice thickness had poor agreement with the volumes measured at 1.25 mm and 0.625 mm, respectively. Moreover, the best agreement was achieved between the slice thicknesses of 1.25 mm and 0.625 mm using the bone algorithm. Conclusion Reconstruction algorithms and slice thicknesses have significant impacts on the volumetric measurements of lung nodules, especially for the small nodules. Therefore, the reconstruction setting in serial CT scans should be consistent in the follow

  15. Evolution of specialization and ecological character displacement: metabolic plasticity matters.

    NARCIS (Netherlands)

    Egas, C.J.M.; Reydon, Th.A.C.; Hemerik, L.

    2005-01-01

    An important question in evolutionary biology, especially with respect to herbivorous arthropods, is the evolution of specialization. In a previous paper, the combined evolutionary dynamics of specialization and ecological character displacement was studied, focusing on the role of herbivore foragin

  16. Vertical Crustal Displacements Due to Surface Fluid Changes

    Institute of Scientific and Technical Information of China (English)

    ZHANG Shiyu; ZHONG Min

    2007-01-01

    Using the model data for surface mass changes of the atmosphere, ocean, soil moisture and snow depth, the vertical crustal displacements of 25 ficual stations in China were calculated according to the loading theory. From the spectral analysis of the results, we can see that the periods of displacements are 12 months and the semi-periods are 6 months. The results also show that the maximum seasonal displacements can reach 20 mm and even larger. The covariance analyses and significance tests show that the coefficients of 96 percent of the stations are significant at the 0.1 significance level. The results show that one of the reasons of the vertical crustal displacements is the changing surface fluid loads.

  17. Displacement of Building Cluster Using Field Analysis Method

    Institute of Scientific and Technical Information of China (English)

    Al Tinghua

    2003-01-01

    This paper presents a field based method to deal with the displacement of building cluster,which is driven by the street widening. The compress of street boundary results in the force to push the building moving inside and the force propagation is a decay process. To describe the phenomenon above, the field theory is introduced with the representation model of isoline. On the basis of the skeleton of Delaunay triangulation,the displacement field is built in which the propagation force is related to the adjacency degree with respect to the street boundary. The study offers the computation of displacement direction and offset distance for the building displacement. The vector operation is performed on the basis of grade and other field concepts.

  18. Health outcomes of crisis driven urban displacement: A conceptual framework

    Science.gov (United States)

    Deola, Claudio; Patel, Ronak B

    2014-01-01

    With urbanisation, cities are increasingly home to greater proportions of the world's population. As this transition has significant implications on human health, the epidemiology of diseases among relatively stable urban populations is growing. As humanitarian crises increasingly drive people to urban centers rather than traditional refugee camps, however, rapid and massive urban displacements will increase in frequency. This paper explores the idea that such urban displacements combine epidemiological features of forced migration, slum conditions and humanitarian disaster contexts. This paper highlights the lack of primary data and the consequent paucity of solid epidemiological literature in the aftermath of rapid massive urban displacements. A framework of health outcomes in urban displacement drawing from the above 3 phenomenon is presented and avenues for improved epidemiologic work described. PMID:28229003

  19. Job displacement and stress-related health outcomes

    DEFF Research Database (Denmark)

    Browning, Martin; Danø, Anne Møller; Heinesen, Eskil

    2006-01-01

    We investigate whether job loss as the result of displacement causes hospitalization for stress-related diseases which are widely thought to be associated with unemployment. In doing this, we use much better data than any previous investigators. Our data are a random 10% sample of the male...... population of Denmark for the years 1981-1999 with full records on demographics, health and work status for each person, and with a link from every working person to a plant. We use the method of matching on observables to estimate the counter-factual of what would have happened to the health of a particular...... group of displaced workers if they had not in fact been displaced. Our results indicate unequivocally that being displaced in Denmark does not cause hospitalization for stress-related disease. An analysis of the power of our test suggests that even though we are looking for a relatively rare outcome...

  20. Measurement of local relative displacements in large structures

    DEFF Research Database (Denmark)

    Tesauro, Angelo; Eder, Martin Alexander; Nielsen, Magda

    2014-01-01

    This paper presents a novel measurement technique to measure local relative displacements between parts of large-scale structures. The measured deformations can be of significant importance for fracture analyses in many different types of structures in general, and for adhesive connections...... in particular. The measurement of small local relative displacements in structures subjected to large global deformations is complex and hardly feasible with conventional measurement methods. Therefore, a Small Displacement Measurement System (SDMS) has been devised. The SDMS is based on stereo photogrammetry...... and capable of measuring 3D local displacements with a high degree of accuracy. In this article, the technique is used to measure local deformations in the vicinity of the adhesive trailing edge joint of a wind turbine rotor blade. The SDMS results correspond well with another independent measurement method....