WorldWideScience

Sample records for volumetric bmd vbmd

  1. Self-reported weight at birth predicts measures of femoral size but not volumetric BMD in eldery men: MrOS.

    Science.gov (United States)

    Javaid, M Kassim; Prieto-Alhambra, Daniel; Lui, Li-Yung; Cawthon, Peggy; Arden, Nigel K; Lang, Thomas; Lane, Nancy E; Orwoll, Eric; Barrett-Conner, Elizabeth; Nevitt, Michael C; Cooper, Cyrus; Cummings, Steven R

    2011-08-01

    The mechanism whereby poor intrauterine growth increases risk of adult hip fracture is unclear. We report the association between birth weight and proximal femoral geometry and density in community-dwelling elderly men. We used self-reported birth weight, measured adult height and weight and proximal femoral quantitative computed tomography (QCT) measurements of femoral neck axis length, cross-sectional area, and volumetric BMD (vBMD) among the participants in the Osteoporotic Fractures in Men (MrOS), a cohort study of community-dwelling US men aged 65 and older. We compared men with birth weight <7 pounds (lower birth weight [LBW]; n = 501) and ≥ 9 pounds (higher birth weight [HBW]; n = 262) with those weighing 7-8.9 pounds (medium birth weight [MBW], referent group; n = 1068) using linear regression adjusting for current age, height, and BMI. The mean age of the 1831 men who had both birth weight and QCT measurements was 73 years (SD 5.9). Compared with the referent MBW, HBW men had concordantly longer femoral neck (+0.16 SD; p = .028) and cross-sectional area (+0.24 SD, p = .001). LBW men had a smaller cross-sectional (-0.26 SD, p < .001) but longer femoral neck for their height (+0.11 SD, p = .05). Neither cortical nor trabecular vBMD at the femoral neck was associated with birth weight. These findings support the hypothesis that the skeletal envelope, but not density, is set, in part, at birth. Further research exploring the association between early developmental factors and lifetime fracture risk is needed and may inform primary preventative strategies for fracture prevention.

  2. Effect of whole-body vibration on BMD: a systematic review and meta-analysis.

    Science.gov (United States)

    Slatkovska, L; Alibhai, S M H; Beyene, J; Cheung, A M

    2010-12-01

    Our systematic review and meta-analysis of randomized controlled trials (RCTs) examining whole-body vibration (WBV) effect on bone mineral density (BMD) found significant but small improvements in hip areal BMD (aBMD) in postmenopausal women and in tibia and spine volumetric BMD in children/adolescents, but not in other BMD measurements in postmenopausal women and young adults. Animal experiments report anabolic bone changes in response to WBV, but data in humans are limited. Our objective is to conduct a systematic review and meta-analysis of RCTs examining WBV effect on BMD. Eligible RCTs included randomized or quasi-randomized trials, with follow-up of ≥ 6 months, examining WBV effects on BMD in ambulatory individuals without secondary causes of osteoporosis. The weighted mean differences between WBV and control groups in absolute pre-post change in spine and hip aBMD, and in spine and tibia trabecular volumetric BMD (vBMD) were calculated. eight RCTs in postmenopausal women (five RCTs), young adults (one RCT), and children and adolescents (two RCTs) were included. The regimens were heterogeneous, study durations were relatively short, and available data was mostly per-protocol. In postmenopausal women, WBV was found to significantly increase hip aBMD (0.015 g cm(-2); 95% confidence interval (CI), 0.008-0.022; n = 131) versus controls, but not spine aBMD (n = 181) or tibia trabecular vBMD (n = 29). In young adults, WBV did not increase spine or hip bone mineral content, or tibia trabecular vBMD (n = 53). In children and adolescents, WBV significantly increased spine (6.2 mg cm(-3); 95% CI, 2.5-10.0; n = 65) and tibia (14.2 mg cm(-3); 95% CI, 5.2-23.2; n = 17) trabecular vBMD. We found significant but small improvements in BMD in postmenopausal women and children and adolescents, but not in young adults. WBV is a promising new modality, but before recommendations can be made for clinical practice, large-scale long-term studies are needed

  3. Comparison of the Spine and Hip BMD Assessments Derived from Quantitative Computed Tomography

    Directory of Open Access Journals (Sweden)

    Xiao-Hui Ma

    2015-01-01

    Full Text Available Quantification of bone mineral density (BMD is being used as the main method to diagnose osteoporosis. Dual-energy X-ray absorptiometry (DXA is the most common tools for measuring BMD. Compared to DXA, quantitative computed tomography (QCT can determine in three dimensions the true volumetric BMD (vBMD at any skeletal site. In addition to the spine, the hip is an important site for axial BMD measurement. This study examines lumbar spine and hip BMD of Chinese adults by QCT. Age related changes in bone mass derived by QCT measurements were determined. The osteoporosis QCT detection rates at the spine and hip are assessed in both female and male, and agreement of skeletal status category between the spine and hip in older adults is also assessed.

  4. Comparison of the relationship between bone marrow adipose tissue and volumetric bone mineral density in children and adults.

    Science.gov (United States)

    Shen, Wei; Velasquez, Gilbert; Chen, Jun; Jin, Ye; Heymsfield, Steven B; Gallagher, Dympna; Pi-Sunyer, F Xavier

    2014-01-01

    Several large-scale studies have reported the presence of an inverse relationship between bone mineral density (BMD) and bone marrow adipose tissue (BMAT) in adults. We aim to determine if there is an inverse relationship between pelvic volumetric BMD (vBMD) and pelvic BMAT in children and to compare this relationship in children and adults. Pelvic BMAT and bone volume (BV) was evaluated in 181 healthy children (5-17yr) and 495 healthy adults (≥18yr) with whole-body magnetic resonance imaging (MRI). Pelvic vBMD was calculated using whole-body dual-energy X-ray absorptiometry to measure pelvic bone mineral content and MRI-measured BV. An inverse correlation was found between pelvic BMAT and pelvic vBMD in both children (r=-0.374, pBMAT as the independent variable, being a child or adult neither significantly contribute to the pelvic BMD (p=0.995) nor did its interaction with pelvic BMAT (p=0.415). The inverse relationship observed between pelvic vBMD and pelvic BMAT in children extends previous findings that found the inverse relationship to exist in adults and provides further support for a reciprocal relationship between adipocytes and osteoblasts.

  5. Comparison of volumetric bone mineral density in the operated and contralateral knee after anterior cruciate ligament and reconstruction: A 1-year follow-up study using peripheral quantitative computed tomography.

    Science.gov (United States)

    Mündermann, Annegret; Payer, Nina; Felmet, Gernot; Riehle, Hartmut

    2015-12-01

    The purpose of this study was to quantify changes in volumetric bone mineral density (vBMD) in the tibial plateau of the operated and contralateral leg measured using peripheral quantitative computed tomography (pQCT) before and 3, 6, and 12 months after anterior cruciate ligament (ACL) reconstruction. The ACL was reconstructed with a hamstring tendon autograft using press-fit fixation. pQCT measurements of the proximal tibia were obtained in 61 patients after ACL reconstruction, and total, cortical, and trabecular vBMD were calculated. vBMD in the operated leg decreased from baseline to 3 months (-12% [total], -11% [cortical], and -12.6% [trabecular]; preconstruction contributed to loss in bone mineral density within the first year after surgery. The role of factors such as time of weight-bearing, joint mechanics, post-traumatic inflammatory reactions, or genetic predisposition in modulating the development of posttraumatic knee osteoarthritis after ACL injury should be further elucidated.

  6. Genetic determinants of trabecular and cortical volumetric bone mineral densities and bone microstructure.

    Directory of Open Access Journals (Sweden)

    Lavinia Paternoster

    Full Text Available Most previous genetic epidemiology studies within the field of osteoporosis have focused on the genetics of the complex trait areal bone mineral density (aBMD, not being able to differentiate genetic determinants of cortical volumetric BMD (vBMD, trabecular vBMD, and bone microstructural traits. The objective of this study was to separately identify genetic determinants of these bone traits as analysed by peripheral quantitative computed tomography (pQCT. Separate GWA meta-analyses for cortical and trabecular vBMDs were performed. The cortical vBMD GWA meta-analysis (n = 5,878 followed by replication (n = 1,052 identified genetic variants in four separate loci reaching genome-wide significance (RANKL, rs1021188, p = 3.6×10⁻¹⁴; LOC285735, rs271170, p = 2.7×10⁻¹²; OPG, rs7839059, p = 1.2×10⁻¹⁰; and ESR1/C6orf97, rs6909279, p = 1.1×10⁻⁹. The trabecular vBMD GWA meta-analysis (n = 2,500 followed by replication (n = 1,022 identified one locus reaching genome-wide significance (FMN2/GREM2, rs9287237, p = 1.9×10⁻⁹. High-resolution pQCT analyses, giving information about bone microstructure, were available in a subset of the GOOD cohort (n = 729. rs1021188 was significantly associated with cortical porosity while rs9287237 was significantly associated with trabecular bone fraction. The genetic variant in the FMN2/GREM2 locus was associated with fracture risk in the MrOS Sweden cohort (HR per extra T allele 0.75, 95% confidence interval 0.60-0.93 and GREM2 expression in human osteoblasts. In conclusion, five genetic loci associated with trabecular or cortical vBMD were identified. Two of these (FMN2/GREM2 and LOC285735 are novel bone-related loci, while the other three have previously been reported to be associated with aBMD. The genetic variants associated with cortical and trabecular bone parameters differed, underscoring the complexity of the genetics of bone parameters. We propose

  7. Phantom-less bone mineral density (BMD) measurement using dual energy computed tomography-based 3-material decomposition

    Science.gov (United States)

    Hofmann, Philipp; Sedlmair, Martin; Krauss, Bernhard; Wichmann, Julian L.; Bauer, Ralf W.; Flohr, Thomas G.; Mahnken, Andreas H.

    2016-03-01

    Osteoporosis is a degenerative bone disease usually diagnosed at the manifestation of fragility fractures, which severely endanger the health of especially the elderly. To ensure timely therapeutic countermeasures, noninvasive and widely applicable diagnostic methods are required. Currently the primary quantifiable indicator for bone stability, bone mineral density (BMD), is obtained either by DEXA (Dual-energy X-ray absorptiometry) or qCT (quantitative CT). Both have respective advantages and disadvantages, with DEXA being considered as gold standard. For timely diagnosis of osteoporosis, another CT-based method is presented. A Dual Energy CT reconstruction workflow is being developed to evaluate BMD by evaluating lumbar spine (L1-L4) DE-CT images. The workflow is ROI-based and automated for practical use. A dual energy 3-material decomposition algorithm is used to differentiate bone from soft tissue and fat attenuation. The algorithm uses material attenuation coefficients on different beam energy levels. The bone fraction of the three different tissues is used to calculate the amount of hydroxylapatite in the trabecular bone of the corpus vertebrae inside a predefined ROI. Calibrations have been performed to obtain volumetric bone mineral density (vBMD) without having to add a calibration phantom or to use special scan protocols or hardware. Accuracy and precision are dependent on image noise and comparable to qCT images. Clinical indications are in accordance with the DEXA gold standard. The decomposition-based workflow shows bone degradation effects normally not visible on standard CT images which would induce errors in normal qCT results.

  8. Bone geometry, volumetric density, microarchitecture, and estimated bone strength assessed by HR-pQCT in Klinefelter syndrome

    DEFF Research Database (Denmark)

    Shanbhogue, Vikram V; Hansen, Stinus; Jørgensen, Niklas Rye;

    2014-01-01

    and height with 31 healthy subjects aged 35.9 ± 8.2 years. Dual-energy X-ray absorptiometry (DXA) and HR-pQCT were performed in all participants, and blood samples were analyzed for hormonal status and bone biomarkers in KS patients. Twenty-one KS patients were on long-term testosterone-replacement therapy.......03) at the tibia in KS patients. In addition, cortical thickness was significantly reduced, both at the radius and tibia (both p testosterone therapy. This study......Although the expected skeletal manifestations of testosterone deficiency in Klinefelter's syndrome (KS) are osteopenia and osteoporosis, the structural basis for this is unclear. The aim of this study was to assess bone geometry, volumetric bone mineral density (vBMD), microarchitecture...

  9. Bone geometry, volumetric density, microarchitecture, and estimated bone strength assessed by HR-pQCT in Klinefelter syndrome.

    Science.gov (United States)

    Shanbhogue, Vikram V; Hansen, Stinus; Jørgensen, Niklas Rye; Brixen, Kim; Gravholt, Claus H

    2014-11-01

    Although the expected skeletal manifestations of testosterone deficiency in Klinefelter's syndrome (KS) are osteopenia and osteoporosis, the structural basis for this is unclear. The aim of this study was to assess bone geometry, volumetric bone mineral density (vBMD), microarchitecture, and estimated bone strength using high-resolution peripheral quantitative computed tomography (HR-pQCT) in patients with KS. Thirty-one patients with KS confirmed by lymphocyte chromosome karyotyping aged 35.8 ± 8.2 years were recruited consecutively from a KS outpatient clinic and matched with respect to age and height with 31 healthy subjects aged 35.9 ± 8.2 years. Dual-energy X-ray absorptiometry (DXA) and HR-pQCT were performed in all participants, and blood samples were analyzed for hormonal status and bone biomarkers in KS patients. Twenty-one KS patients were on long-term testosterone-replacement therapy. In weight-adjusted models, HR-pQCT revealed a significantly lower cortical area (p < 0.01), total and trabecular vBMD (p = 0.02 and p = 0.04), trabecular bone volume fraction (p = 0.04), trabecular number (p = 0.05), and estimates of bone strength, whereas trabecular spacing was higher (p = 0.03) at the tibia in KS patients. In addition, cortical thickness was significantly reduced, both at the radius and tibia (both p < 0.01). There were no significant differences in indices of bone structure, estimated bone strength, or bone biomarkers in KS patients with and without testosterone therapy. This study showed that KS patients had lower total vBMD and a compromised trabecular compartment with a reduced trabecular density and bone volume fraction at the tibia. The compromised trabecular network integrity attributable to a lower trabecular number with relative preservation of trabecular thickness is similar to the picture found in women with aging. KS patients also displayed a reduced cortical area and thickness at the tibia, which in

  10. Orchidectomy-induced alterations in volumetric bone density, cortical porosity and strength of femur are attenuated by dietary conjugated linoleic acid in aged guinea pigs.

    Science.gov (United States)

    DeGuire, Jason R; Mak, Ivy L; Lavery, Paula; Agellon, Sherry; Wykes, Linda J; Weiler, Hope A

    2015-04-01

    Age-related osteoporosis and sarcopenia are ascribed in part to reductions in anabolic hormones. Dietary conjugated linoleic acid (CLA) improves lean and bone mass, but its impact during androgen deficiency is not known. This study tested if CLA would attenuate the effects of orchidectomy (ORX)-induced losses of bone and lean tissue. Male guinea pigs (n=40; 70-72 weeks), were randomized into four groups: (1) SHAM+Control diet, (2) SHAM+CLA diet, (3) ORX+Control diet, (4) ORX+CLA diet. Baseline blood sampling and dual-energy X-ray absorptiometry (DXA) scans were conducted, followed by surgery 4 days later with the test diets started 7 days after baseline sampling. Serial blood sampling and DXA scans were repeated 2, 4, 8 and 16 weeks on the test diets. Body composition and areal BMD (aBMD) of whole body, lumbar spine, femur and tibia were measured using DXA. At week 16, muscle protein fractional synthesis rate (FSR), volumetric BMD (vBMD), microarchitecture and bone strength were assessed. Body weight declined after SHAM and ORX surgery, with slower recovery in the ORX group. Dietary CLA did not affect weight or lean mass, but attenuated gains in fat mass. Lean mass was stable in SHAM and reduced in ORX by 2 weeks with whole body and femur bone mineral content (BMC) reduced by 4 weeks; CLA did not alter BMC. By week 16 ORX groups had lower free testosterone and myofibrillar FSR, yet higher cortisol, osteocalcin and ionized calcium with no alterations due to CLA. ORX+Control had higher prostaglandin E2 (PGE2) and total alkaline phosphatase compared to SHAM+Control whereas ORX+CLA were not different from SHAM groups. Femur metaphyseal vBMD was reduced in ORX+CTRL with the reduction attenuated by CLA. Femur cortical thickness (Ct.Th.) and biomechanical strength were reduced and cortical porosity (Ct.Po.) elevated by ORX and attenuated by CLA. This androgen deficient model with a sarcopenic-osteoporotic phenotype similar to aging men responded to dietary CLA with

  11. Bone Geometry, Volumetric Bone Mineral Density, Microarchitecture and Estimated Bone Strength in Caucasian Females with Systemic Lupus Erythematosus. A Cross-Sectional Study Using HR-pQCT

    DEFF Research Database (Denmark)

    Hansen, Stinus; Gudex, Claire; Ahrberg, Fabian;

    2014-01-01

    by finite element analysis (FEA) at the distal radius and tibia to assess bone characteristics beyond BMD that may contribute to the increased risk of fracture. Thirty-three Caucasian women with SLE (median age 48, range 21-64 years) and 99 controls (median age 45, range 21-64 years) were studied. Groups...... were comparable in radius regarding geometry and vBMD, but SLE patients had lower trabecular number (-7 %, p FEA-estimated failure load compared to controls (-10 %, p ....01], trabecular number (-9 %, p FEA-estimated bone...

  12. BMD improvements after operation for primary hyperparathyroidism

    DEFF Research Database (Denmark)

    Rolighed, Lars; Vestergaard, Peter; Heickendorff, Lene

    2013-01-01

    PURPOSE: This study aims to quantify bone mineral density (BMD) changes following surgery in patients with primary hyperparathyroidism (PHPT) and to assess their relationship with clinical and biochemical variables. METHODS: A historic cohort of 236 PHPT patients with DXA scans pre- and 1-year...

  13. Advanced Operating Systems Concepts for BMD Applications.

    Science.gov (United States)

    1982-06-03

    Results The key results of this work are reported in detail in the attached theses of Branimir Gajic and Debra Lane. In particular, Gajic’s thesis...below: Theses "A Distributed Operating System for BMD Applications," Branimir Gajic, TR-CS-82-4. "A Communications Subsystem Based on a CSMA/CD...Cohen Graduate Assistant Uuaim-’.v :52 ) Debra Lane Graduate Assistant J ’st-i-t: Branimir Gajic Graduate Assistant -w4 Robert Souza Graduate

  14. Population=stratified analysis of bone mineral density distribution in cervical and lumbar vertebrae of chinese from quantitative computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Yong; Cheng, Xiaoguang; Cai, Wei; Wang, Ling; Duanmu, Yangyang; Zhang, Chen Xin [Dept. of Radiology, The Fourth Clinical Medical College of Peking University, Beijing Jishuitan Hospital, Beijing (China); Zhou, Zhuang [Dept. of Orthopedic Oncology, The Third Hospital of Hebei Medical University, Shijiazhuang (China); Wu, Cheng' ai; Zhao, Danhui; Wang, Chao [Beijing Institute of Traumatology and Orthopedics, Beijing (China); Tian, Wei [Dept. of Spine Surgery, The Fourth Clinical Medical College of Peking University, Beijing Jishuitan Hospital, Beijing (China)

    2016-09-15

    To investigate the bone mineral density (BMD) of cervical vertebrae in a population-stratified manner and correlate with that of the lumbar vertebrae. Five hundred and ninety-eight healthy volunteers (254 males, 344 females), ranging from 20 to 64 years of age, were recruited for volumetric BMD (vBMD) measurements by quantitative computed tomography. Basic information (age, height, weight, waistline, and hipline), and vBMD of the cervical and lumbar vertebrae (C2–7 and L2–4) were recorded. Comparisons among sex, age groups and different levels of vertebrae were analyzed using analysis of variance. Linear regression was performed for relevance of different vertebral levels. The vBMD of cervical and lumbar vertebrae was higher in females than males in each age group. The vBMD of the cervical and lumbar vertebrae in males and the vBMD of lumbar vertebrae in females decreased with aging. In each age group, the vBMD of the cervical vertebrae was higher than that of the lumbar vertebrae with gradual decreases from C2 to C7 except for C3; moreover, the vBMD of C6 and C7 was significantly different from that of C2–5. Correlations of vBMD among different cervical vertebrae (females: r = 0.62–0.94; males: r = 0.63–0.94) and lumbar vertebrae (males: r = 0.93–0.98; females: r = 0.82–0.97) were statistically significant at each age group. The present study provided normative data of cervical vertebrae in an age- and sex-stratified manner. Sex differences in vBMD prominently vary with age, which can be helpful to design a more comprehensive pre-operative surgical plan.

  15. Population-Stratified Analysis of Bone Mineral Density Distribution in Cervical and Lumbar Vertebrae of Chinese from Quantitative Computed Tomography

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Yong [Department of Radiology, The Fourth Clinical Medical College of Peking University, Beijing Jishuitan Hospital, Beijing 100035 (China); Zhou, Zhuang [Department of Orthopedic Oncology, The Third Hospital of Hebei Medical University, Shijiazhuang 050051 (China); Wu, Cheng' ai; Zhao, Danhui; Wang, Chao [Beijing Institute of Traumatology and Orthopedics, Beijing 100035 (China); Cheng, Xiaoguang; Cai, Wei; Wang, Ling; Duanmu, Yangyang; Zhang, Chenxin [Department of Radiology, The Fourth Clinical Medical College of Peking University, Beijing Jishuitan Hospital, Beijing 100035 (China); Tian, Wei [Department of Spine Surgery, The Fourth Clinical Medical College of Peking University, Beijing Jishuitan Hospital, Beijing 100035 (China)

    2016-11-01

    To investigate the bone mineral density (BMD) of cervical vertebrae in a population-stratified manner and correlate with that of the lumbar vertebrae. Five hundred and ninety-eight healthy volunteers (254 males, 344 females), ranging from 20 to 64 years of age, were recruited for volumetric BMD (vBMD) measurements by quantitative computed tomography. Basic information (age, height, weight, waistline, and hipline), and vBMD of the cervical and lumbar vertebrae (C2–7 and L2–4) were recorded. Comparisons among sex, age groups and different levels of vertebrae were analyzed using analysis of variance. Linear regression was performed for relevance of different vertebral levels. The vBMD of cervical and lumbar vertebrae was higher in females than males in each age group. The vBMD of the cervical and lumbar vertebrae in males and the vBMD of lumbar vertebrae in females decreased with aging. In each age group, the vBMD of the cervical vertebrae was higher than that of the lumbar vertebrae with gradual decreases from C2 to C7 except for C3; moreover, the vBMD of C6 and C7 was significantly different from that of C2–5. Correlations of vBMD among different cervical vertebrae (females: r = 0.62–0.94; males: r = 0.63–0.94) and lumbar vertebrae (males: r = 0.93–0.98; females: r = 0.82–0.97) were statistically significant at each age group. The present study provided normative data of cervical vertebrae in an age- and sex-stratified manner. Sex differences in vBMD prominently vary with age, which can be helpful to design a more comprehensive pre-operative surgical plan.

  16. QUS of phalanx, DXA, BMD, Osteoporosis

    Directory of Open Access Journals (Sweden)

    A Soltani

    2004-03-01

    Full Text Available DXL of calcaneus is a portable method for BMD. This study determined a cut off point for DXL in osteoporosis diagnosis. In 510 healthy postmenopausal women, BMD of axial regions with DXA (DPX-MD, GE,Lunar Corp, Madison, WI and heel with DXL (Demeteck- Sweden, measured. The agreement of two methods and cut off point for DXL in defining osteoporosis, obtained. DXA found osteoporosis in 34.3% and in DXL in 26.1% of cases. Agreement (Kappa was 0.407 for spine and 0.347 for femur. T-score = -1.8 for spine and T-score = -2.2 for femur were the cut off points of DXL in diagnosis of osteoporosis (sensitivity=84% specificity=60% and (sensitivity=84% and specificity=70%, respectively. Area under curve for regions were 0.807 (P=0.000 and 0.859 (P=0.000, respectively. These results mean DXL can not be used as a replacement for DXA, but it may can be used as a screening method for osteoporosis.

  17. QUS of phalanx, DXA, BMD, Osteoporosis

    Directory of Open Access Journals (Sweden)

    A Soltani

    2004-11-01

    Full Text Available DXL of calcaneus is a portable method for BMD. This study determined a cut off point for DXL in osteoporosis diagnosis. In 510 healthy postmenopausal women, BMD of axial regions with DXA (DPX-MD, GE,Lunar Corp, Madison, WI and heel with DXL (Demeteck- Sweden, measured. The agreement of two methods and cut off point for DXL in defining osteoporosis, obtained. DXA found osteoporosis in 34.3% and in DXL in 26.1% of cases. Agreement (Kappa was 0.407 for spine and 0.347 for femur. T-score = -1.8 for spine and T-score = -2.2 for femur were the cut off points of DXL in diagnosis of osteoporosis (sensitivity=84% specificity=60% and (sensitivity=84% and specificity=70%, respectively. Area under curve for regions were 0.807 (P=0.000 and 0.859 (P=0.000, respectively. These results mean DXL can not be used as a replacement for DXA, but it may can be used as a screening method for osteoporosis.

  18. Bone geometry, volumetric density, microarchitecture, and estimated bone strength assessed by HR-pQCT in adult patients with hypophosphatemic rickets

    DEFF Research Database (Denmark)

    Shanbhogue, Vikram V; Hansen, Stinus; Folkestad, Lars;

    2015-01-01

    at the distal radius and tibia were placed in a constant proportion to the entire length of the bone in both patients and healthy volunteers. In age- and weight-adjusted models, HR patients had significantly higher total bone cross-sectional areas (radius 36%, tibia 20%; both p ... impact of lower vBMD and trabecular number on bone strength seems to be compensated by an increase in bone diameter, resulting in HR patients having normal estimates of bone strength. © 2014 American Society for Bone and Mineral Research....

  19. Testosterone and BMD in elite male lightweight rowers

    DEFF Research Database (Denmark)

    Vinther, A; Kanstrup, I-L; Christiansen, E

    2008-01-01

    ), free testosterone (FT), dihydrotestosterone (DHT) and sex hormone binding globulin (SHBG) and additional parameters related to bone metabolism were measured. Plasma concentrations of TT, FT and DHT were in the lower part of the normal range, while BMD was close to or above normal. BMD of total body...

  20. Testosterone and BMD in Elite Male Lightweight Rowers

    DEFF Research Database (Denmark)

    Vinther, A.; Christiansen, E.; Ekdahl, C.

    2008-01-01

    ), free testosterone (IFT), dihydrotestosterone (DHT) and sex hormone binding globulin (SHBG) and additional parameters related to bone metabolism were measured. Plasma concentrations of TT, FT and DHT were in the lower part of the normal range, while BMD was close to or above normal. BMD of total body...

  1. Parathyroidectomy improves bone geometry and microarchitecture in female patients with primary hyperparathyroidism. A 1-year prospective controlled study using high resolution peripheral quantitative computed tomography

    DEFF Research Database (Denmark)

    Hansen, Stinus; Hauge, Ellen M; Rasmussen, Lars

    2012-01-01

    controlled study, high-resolution peripheral quantitative computed tomography (HR-pQCT) was used to evaluate changes in bone geometry, volumetric BMD (vBMD), microarchitecture, and estimated strength in female patients with PHPT before and 1 year after PTX, compared to healthy controls. Twenty-seven women...

  2. The study of technical error analysis on BMD using DEXA

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Yeong Han [Daegu Catholic University Hospital, Daegu (Korea, Republic of); Jo, Gwang Ho [Daegu Catholic University, Daegu (Korea, Republic of)

    2006-12-15

    This study was conducted to search for the type of technical error in DEXA (dual-energy X-ray absorptiometry) and the effect of error to measurement of BMD. The changes of BMD (g/cm{sup 2}, T-score) by patients information (Age, Weight, Height, Manopause age) input error and Confirming ROI error were investigated. Using spine phantom, we canned 10 times by age (5, 10), weight (10, 20 kg), height (5, 10 cm), manopause age (5, 10) increase and decrease respectively. Scanning region (L-spine, femur, Forearm) of 10 patients was calculated by changing ROI respectively. Analysis of difference for mean (precision 1%) were carried out. There error of patient information (Age, Weight, Height, Manopause age) was not changed differently. In confirming ROI, the BMD and T-score of L-spine involving T-12 was decreased to 0.063 g/cm{sup 2}, 0.3 and involving L-5 increased to 0.077 g/cm{sup 2}, 0.5. In narrowing 1 cm of vertical line of ROI, the BMD and T-score decreased to 0.006 g/cm{sup 2}, 0.1 and in 2 cm, 0.021 g/cm{sup 2}, 0.15, each. In hip ROI, Upper and left shift (0.5 cm) of line was not influenced BMD and T-score. In 0.5 cm lower shift (lesser trochanter below), the BMD and T-score increased 0.031 g/cm{sup 2}, 0.3 and in 1 cm 0.094 g/cm{sup 2}, 0.65, each. In forearm ROI, the BMD and T-score decreased 0.042 g/cm{sup 2}, 0.9 involving 1 cm lower wrist. And expanding 1 cm of vertical line, the BMD and T-score decreased 0.008 g/cm{sup 2}, 0.1 and in 2 cm, 0.021 g/cm{sup 2}, 0.3, each. The L-spine, hip, forearm ROI error was changed differently. There are so many kinds of technical error in BMD processing. Errors according to age, weight, height, manopause age did not influent to BMD (g/cm{sup 2}) and T-score. There are mean differences BMD and T-score in confirming ROI. For the precision exam, in L-spine processing, L1-4 have to confirmed without shift of ROI vertical line. In hip processing, the ROI have to included greater trochanter, femur head and lesser trochanter. In

  3. Volumetric Virtual Environments

    Institute of Scientific and Technical Information of China (English)

    HE Taosong

    2000-01-01

    Driven by fast development of both virtual reality and volume visualization, we discuss some critical techniques towards building a volumetric VR system, specifically the modeling, rendering, and manipulations of a volumetric scene.Techniques such as voxel-based object simplification, accelerated volume rendering,fast stereo volume rendering, and volumetric "collision detection" are introduced and improved, with the idea of demonstrating the possibilities and potential benefits of incorporating volumetric models into VR systems.

  4. Comparison of calibrated and uncalibrated bone mineral density by CT to DEXA in menopausal women.

    Science.gov (United States)

    Miyabara, Y; Holmes, D; Camp, J; Miller, V M; Kearns, A E

    2012-08-01

    Coronary artery disease and osteoporosis increase in women after menopause. Computed tomography (CT) scans of the heart used to evaluate coronary arterial calcification include images of the thoracic vertebrae. The utility of using these images to assess bone health in women remains to be defined. Analyses of thoracic spine volumetric bone mineral density (vBMD) from CT scans of the heart were performed to determine how specific calibration affects the ability to assess vBMD in recently menopausal women and to evaluate how vBMD relates to areal bone mineral density (aBMD) using dual-energy X-ray absorptiometry (DEXA). Women (n = 111) enrolled in the Kronos Early Estrogen Prevention Study (KEEPS) at Mayo Clinic underwent a CT scan of the heart that included calibration phantoms and a DEXA of the lumbar spine. The Spine Cancer Assessment program was used to determine vBMD of thoracic vertebrae with and without the calibration correction. Trabecular bone vBMD at T8 averaged 163.57±28.58 and 157.94±27.55 mg/cc (mean±standard deviation, SD) for calibrated and uncalibrated values, respectively. The relationship between calibrated and uncalibrated measures approached unity (R = 0.98). Lumbar spine (L2-4) aBMD was 1.19±0.16 g/cm(2) (mean±SD). Both calibrated and uncalibrated thoracic vBMD correlated positively and significantly with lumbar aBMD, but the relationship was less than unity (R = 0.63). Uncalibrated measures of thoracic spine vBMD obtained from CT scans of the heart may provide clinically relevant information about bone health and osteoporosis/osteopenia risk in recently menopausal women.

  5. Distribution of bone density and cortical thickness in the proximal femur and their association with hip fracture in postmenopausal women: a quantitative computed tomography study.

    Science.gov (United States)

    Yang, L; Udall, W J M; McCloskey, E V; Eastell, R

    2014-01-01

    The quantitative computed tomography (QCT) scans in an individually matched case-control study of women with hip fracture were analysed. There were widespread deficits in the femoral volumetric bone mineral density (vBMD) and cortical thickness of cases, and cortical vBMD and thickness discriminated hip fracture independently of BMD by dual-energy X-ray absorptiometry (DXA). Acknowledging the limitations of QCT associated with partial volume effects, we used QCT in an individually matched case-control study of women with hip fracture to better understand its structural basis. Fifty postmenopausal women (55-89 years) who had sustained hip fractures due to low-energy trauma underwent QCT scans of the contralateral hip within 3 months of the fracture. For each case, postmenopausal women, matched by age (±5 years), weight (±5 kg) and height (±5 cm), were recruited as controls. We quantified cortical, trabecular and integral vBMD and apparent cortical thickness (AppCtTh) in four quadrants of cross-sections along the length of the femoral head (FH), femoral neck (FN), intertrochanter and trochanter and examined their association with hip fracture. Women with hip or intracapsular (IC) fracture had significantly (p hip and IC fractures independent of hip areal BMD (aBMD). The combination of AppCtTh and trabecular or integral vBMD discriminated hip fracture, whereas the combination of FH and FN AppCtTh discriminated IC fracture significantly (p hip aBMD. Deficits in vBMD and AppCtTh in cases were widespread in the proximal femur, and cortical vBMD and AppCtTh discriminated hip fracture independently of aBMD by DXA.

  6. Defects in cortical microarchitecture among African-American women with type 2 diabetes

    Science.gov (United States)

    Yu, Elaine W.; Putman, Melissa S.; Derrico, Nicolas; Abrishamanian-Garcia, Gabriela; Finkelstein, Joel S.; Bouxsein, Mary L.

    2015-01-01

    Introduction/Purpose Fracture risk is increased in patients with type 2 diabetes mellitus (DM2) despite normal areal bone mineral density (aBMD). DM2 is more common in African-Americans than in Caucasians. It is not known whether African-American women with DM2 have deficits in bone microstructure. Methods We measured aBMD at the spine and hip by DXA, and volumetric BMD (vBMD) and microarchitecture at the distal radius and tibia by HR-pQCT in 22 DM2 and 78 non-diabetic African-American women participating in the Study of Women Across the Nation (SWAN). We also measured fasting glucose and HOMA-IR. Results Age, weight, and aBMD at all sites were similar in both groups. At the radius, cortical porosity was 26% greater, while cortical vBMD and tissue mineral density were lower in women with DM2 than in controls. There were no differences in radius total vBMD or trabecular vBMD between groups. Despite inferior cortical bone properties at the radius, FEA-estimated failure load was similar between groups. Tibia vBMD and microarchitecture were also similar between groups. There were no significant associations between cortical parameters and duration of DM2 or HOMA-IR. However, among women with DM2, higher fasting glucose levels were associated with lower cortical vBMD (r=−0.54, p=0.018). Conclusions DM2 and higher fasting glucose are associated with unfavorable cortical bone microarchitecture at the distal radius in African-American women. These structural deficits may contribute to the increased fracture risk among women with DM2. Further our results suggest that hyperglycemia may be involved in mechanisms of skeletal fragility associated with DM2. PMID:25398431

  7. The influences of bowel condition with lumbar spine BMD measurement

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Joon; Lee, Hoo Min; Lee, Jung Min; Kwon, Soon Mu; Cho, Hyung Wook [Dept. of Radiologic Technology, Dongnam Health College, Suwon (Korea, Republic of); Kim, Yun Min; Kang, Yeong Han; Kim, Boo Soon; Kim, Jung Soo [Dept. of Diagonostic Radiology, Samsung Medical Center, Seoul (Korea, Republic of)

    2014-12-15

    Bone density measurement use of diagnosis of osteoporosis and it is an important indicator for treatment as well as prevention. But errors in degree of precision of BMD can be occurred by status of patient, bone densitometer and radiological technologist. Therefore the author evaluated that how BMD changes according to the condition of the patient. As Lumbar region, which could lead to substantial effects on bone density by diverse factors such as the water, food, intentional bowels. We recognized a change of bone mineral density in accordance with the height of the water tank and in the presence or absence of the gas using the Aluminum Spine Phantom. We also figured out the influence of bone mineral density by increasing the water and food into a target on the volunteers. Measured bone mineral density through Aluminum Spine Phantom had statistically significant difference accordance with increasing the height of water tank(p=0.026). There was no significant difference in BMD according to the existence of the bowl gas(p=0.587). There was no significant difference in a study of six people targeted volunteers in the presence or absence of the food(p=0.812). And also there was no significant difference according to the existence of water(p=0.618). If it is not difficult to recognize the surround of bone in measuring BMD of lumbar bone, it is not the factor which has the great effect on bone mineral density whether the test is after endoscopic examination of large intestine and patient’s fast or not.

  8. Recreational football training decreases risk factors for bone fractures in untrained premenopausal women

    DEFF Research Database (Denmark)

    Helge, Eva Wulff; Aagaard, Per; Jakobsen, Markus D.

    2010-01-01

    The present intervention was designed to investigate whether a 14-week period of regular recreational association football (F) or endurance running (R) has an effect on the risk of falls and bone fractures due to gains in muscle function and volumetric bone mineral density (vBMD). Fifty healthy u...

  9. The Role of Body Weight on Bone in Anorexia Nervosa

    DEFF Research Database (Denmark)

    Frølich, Jacob; Hansen, Stinus; Winkler, Laura Al-Dakhiel

    2017-01-01

    Anorexia nervosa (AN) is associated with decreased bone mineral density and increased risk of fracture. The aim of this study was to assess bone geometry, volumetric bone mineral density (vBMD), trabecular microarchitecture and estimated failure load in weight-bearing vs. non-weight-bearing bones...

  10. Baseline Vitamin D Status is Predictive of Longitudinal Change in Tibial BMD in Knee Osteoarthritis (OA)

    Science.gov (United States)

    With its lack of effective treatment and high prevalence, the public health impact of OA is substantial. Peri-articular bone in OA can be evaluated with the medial:lateral tibial BMD ratio (M:L BMD) obtained from dual x-ray absorptiometry (DXA). Higher M:L BMD is associated with medial OA features...

  11. Areal and Volumetric Bone Mineral Density and Geometry at Two Levels of Protein Intake During Caloric Restriction: A Randomized, Controlled Trial

    OpenAIRE

    Sukumar, Deeptha; Ambia-Sobhan, Hasina; Zurfluh, Robert; Schlussel, Yvette; Stahl, Theodore J; Gordon, Chris L; SHAPSES, SUE A.

    2010-01-01

    Weight reduction induces bone loss by several factors, and the effect of higher protein (HP) intake during caloric restriction on bone mineral density (BMD) is not known. Previous study designs examining the longer-term effects of HP diets have not controlled for total calcium intake between groups and have not examined the relationship between bone and endocrine changes. In this randomized, controlled study, we examined how BMD (areal and volumetric), turnover markers, and hormones [insulin-...

  12. Effect of Spinal Degenerative Changes on Volumetric Bone Mineral Density of the Central Skeleton as Measured by Quantitative Computed Tomography

    Energy Technology Data Exchange (ETDEWEB)

    Guglielmi, G. [Hospital ' Casa Sollievo della Sofferenza' , San Giovanni Rotondo (Italy). Dept. of Radiology; Floriani, I.; Torri, V.; Li, J.; Kuijk, C. van; Genant, H.K.; Lang, T.F. [Scientific Inst. ' Mario Negri' , Milan (Italy). Biometry and Data Management Unit

    2005-05-01

    Purpose: To evaluate the impact of degenerative changes due to osteoarthritis (OA) at the spine on volumetric bone mineral density (BMD) as measured by volumetric quantitative computed tomography (vQCT). Material and Methods: Eighty-four elderly women (mean age 73 {+-}6 years), comprising 33 with vertebral fractures assessed by radiographs and 51 without vertebral fractures, were studied. Trabecular, cortical, and integral BMD were examined at the spine and hip using a helical CT scanner and were compared to dual X-ray absorptiometry (DXA) measurements at the same sites. OA changes visible on the radiographs were categorized into two grades according to severity. Differences in BMD measures obtained in the two groups of patients defined by OA grade using the described radiologic methods were compared using analysis of variance. Standardized difference (effect sizes) was also compared between radiologic methods. Results: Spinal trabecular BMD did not differ significantly between OA grade 0 and OA grade. Spinal cortical and integral BMD measures showed statistically significant differences, as did the lumbar spine DXA BMD measurement (13%, P{approx_equal}0.02). The QCT measurements at the hip were also higher in OA subjects. Femoral trabecular BMD was 3-15% higher in OA grade subjects than in OA grade 0 subjects. The cortical BMD measures in the CT{sub T}OT{sub F}EM and CT{sub T}ROCH ROI's were also higher in the OA subjects. The integral QCT BMD measures in the hip showed difference between grades OA and 0. The DXA measurements in the neck and trochanter ROI's showed smaller differences (9 and 1%, respectively). There were no statistically significant differences in bone size. Conclusion: There is no evidence supporting that trabecular BMD measurements by QCT are influenced by OA. Instead, degenerative changes have an effect on both cortical and integral QCT, and on DXA at the lumbar spine and the hip. For subjects with established OA, assessment of BMD by

  13. Bone mass and microarchitecture in CKD patients with fracture.

    Science.gov (United States)

    Nickolas, Thomas L; Stein, Emily; Cohen, Adi; Thomas, Valerie; Staron, Ronald B; McMahon, Donald J; Leonard, Mary B; Shane, Elizabeth

    2010-08-01

    Patients with predialysis chronic kidney disease (CKD) have increased risk for fracture, but the structural mechanisms underlying this increased skeletal fragility are unknown. We measured areal bone mineral density (aBMD) by dual-energy x-ray absorptiometry at the spine, hip, and radius, and we measured volumetric BMD (vBMD), geometry, and microarchitecture by high-resolution peripheral quantitative computed tomography (HR-pQCT) at the radius and tibia in patients with CKD: 32 with fracture and 59 without fracture. Patients with fracture had lower aBMD at the spine, total hip, femoral neck, and the ultradistal radius, the last having the strongest association with fracture. By HR-pQCT of the radius, patients with fracture had lower cortical area and thickness, total and trabecular vBMD, and trabecular number and greater trabecular separation and network heterogeneity. At the tibia, patients with fracture had significantly lower cortical area, thickness, and total and cortical density. Total vBMD at both radius and tibia most strongly associated with fracture. By receiver operator characteristic curve analysis, patients with longer duration of CKD had area under the curve of >0.75 for aBMD at both hip sites and the ultradistal radius, vBMD and geometry at the radius and tibia, and microarchitecture at the tibia. In summary, patients with predialysis CKD and fractures have lower aBMD by dual-energy x-ray absorptiometry and lower vBMD, thinner cortices, and trabecular loss by HR-pQCT. These density and structural differences may underlie the increased susceptibility to fracture among patients with CKD.

  14. Volumetric composition of nanocomposites

    DEFF Research Database (Denmark)

    Madsen, Bo; Lilholt, Hans; Mannila, Juha

    2015-01-01

    Detailed characterisation of the properties of composite materials with nanoscale fibres is central for the further progress in optimization of their manufacturing and properties. In the present study, a methodology for the determination and analysis of the volumetric composition of nanocomposites...... is presented, using cellulose/epoxy and aluminosilicate/polylactate nanocomposites as case materials. The buoyancy method is used for the accurate measurements of materials density. The accuracy of the method is determined to be high, allowing the measured nanocomposite densities to be reported with 5...... significant figures. The plotting of the measured nanocomposite density as a function of the nanofibre weight content is shown to be a first good approach of assessing the porosity content of the materials. The known gravimetric composition of the nanocomposites is converted into a volumetric composition...

  15. A study on the change of bone mineral density (BMD) by life habit and physical condition

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Sun Geun [Woosuk University Oriental Medical Hospital, Wanju (Korea, Republic of)

    2006-09-15

    To evaluate the correlation between BMD and life habit such as drinking exercise smoking or physical condition such as age, sex, height, weight, body mass index (BMI). I evaluated the BMD of the femoral neck and L2-L4 spines of 321 persons who took a regular health screening in Woosuk university oriental medical hospital from February to April in 2006 by dual energy bone mineral densitometry. The age of persons ranged from 20 years to 75 years (mean 45.10 {+-} 11.54) and there were 160 males and 161 females. In males, BMD of the femoral head was highest at 2nd decade, BMD of the spine was highest at 4th decade, and BMD of both femoral head and lumbar spine was lowest at 6th decade. In fenales, BMD of both femoral head and lumbar spine was highest at 4th decade and lowest at 6th decade. Among the various physical conditions, only height of persons showed significant correlation with BMD in both males and females, BMD was increased according to increasing height. In males, BMD of persons who had habit such as drinking, exercise or smoking did not show significant change statistically. But in females, drinking group showed high BMD relative to non-drinking group in both femoral head and lumbar spine. BMD was different according to age, sex, height and life habit. Especially aged people showed osteoporotic change progressively. More persistent effort is needed to find out the factors decreasing BMD for prevention of problems by osteoporosis.

  16. Characterizing trabecular bone structure for assessing vertebral fracture risk on volumetric quantitative computed tomography

    Science.gov (United States)

    Nagarajan, Mahesh B.; Checefsky, Walter A.; Abidin, Anas Z.; Tsai, Halley; Wang, Xixi; Hobbs, Susan K.; Bauer, Jan S.; Baum, Thomas; Wismüller, Axel

    2015-03-01

    While the proximal femur is preferred for measuring bone mineral density (BMD) in fracture risk estimation, the introduction of volumetric quantitative computed tomography has revealed stronger associations between BMD and spinal fracture status. In this study, we propose to capture properties of trabecular bone structure in spinal vertebrae with advanced second-order statistical features for purposes of fracture risk assessment. For this purpose, axial multi-detector CT (MDCT) images were acquired from 28 spinal vertebrae specimens using a whole-body 256-row CT scanner with a dedicated calibration phantom. A semi-automated method was used to annotate the trabecular compartment in the central vertebral slice with a circular region of interest (ROI) to exclude cortical bone; pixels within were converted to values indicative of BMD. Six second-order statistical features derived from gray-level co-occurrence matrices (GLCM) and the mean BMD within the ROI were then extracted and used in conjunction with a generalized radial basis functions (GRBF) neural network to predict the failure load of the specimens; true failure load was measured through biomechanical testing. Prediction performance was evaluated with a root-mean-square error (RMSE) metric. The best prediction performance was observed with GLCM feature `correlation' (RMSE = 1.02 ± 0.18), which significantly outperformed all other GLCM features (p GLCM feature correlation also significantly outperformed MDCTmeasured mean BMD (RMSE = 1.11 ± 0.17) (pGLCM-derived texture features.

  17. Loss of hip BMD in older men: the osteoporotic fractures in men (MrOS) study.

    Science.gov (United States)

    Cawthon, Peggy M; Ewing, Susan K; McCulloch, Charles E; Ensrud, Kristine E; Cauley, Jane A; Cummings, Steven R; Orwoll, Eric S

    2009-10-01

    Previous studies in older men have not evaluated whether loss of BMD or BMC accelerates nonlinearly with age. This study aimed to describe hip bone loss (both in BMC and BMD) in older men and to test whether BMD loss accelerates with age in an exponential manner in a cohort of 4720 community-dwelling men >or=65 yr of age. Men had two to three measures of femoral neck (FN) BMD (by DXA) over an average follow-up of 4.6 yr. Change in BMD during follow-up was estimated from mixed effects regression models; the significance of a quadratic term for age was evaluated. Mean FN BMD loss was 0.013 g/cm(2) (-1.72%) during follow-up. The quadratic term for age was significant, and the model showed that bone loss accelerated with age. Estimated loss of FN BMD over follow-up for men 85 yr of age (0.021 g/cm(2)) was 2.5 times greater than the loss expected for men 65 yr of age (0.008 g/cm(2)); such bone loss in 85-yr-old men may be sufficient to increase the risk of hip fracture by 25% (HR per 0.021 g/cm(2) cross-sectional decrease in FN BMD: 1.25; 95% CI: 1.18-1.31) over 4.6 yr. Men with lower BMD at baseline lost the most BMD over follow-up. Although average bone loss over time is modest in older men, there is considerable variability in rate of loss. Older men and those with lower BMD lose bone more rapidly, offering potential explanation for the increasing risk of fracture with advancing age.

  18. Flexible Volumetric Structure

    Science.gov (United States)

    Cagle, Christopher M. (Inventor); Schlecht, Robin W. (Inventor)

    2014-01-01

    A flexible volumetric structure has a first spring that defines a three-dimensional volume and includes a serpentine structure elongatable and compressible along a length thereof. A second spring is coupled to at least one outboard edge region of the first spring. The second spring is a sheet-like structure capable of elongation along an in-plane dimension thereof. The second spring is oriented such that its in-plane dimension is aligned with the length of the first spring's serpentine structure.

  19. Catch up in bone acquisition in young adult men with late normal puberty.

    Science.gov (United States)

    Darelid, Anna; Ohlsson, Claes; Nilsson, Martin; Kindblom, Jenny M; Mellström, Dan; Lorentzon, Mattias

    2012-10-01

    The aim of this study was to investigate the development of bone mineral density (BMD) and bone mineral content (BMC) in relation to peak height velocity (PHV), and to investigate whether late normal puberty was associated with remaining low BMD and BMC in early adulthood in men. In total, 501 men (mean ± SD, 18.9 ± 0.5 years of age at baseline) were included in this 5-year longitudinal study. Areal BMD (aBMD) and BMC, volumetric BMD (vBMD) and cortical bone size were measured using dual-energy X-ray absorptiometry (DXA) and pQCT. Detailed growth and weight charts were used to calculate age at PHV, an objective assessment of pubertal timing. Age at PHV was a strong positive predictor of the increase in aBMD and BMC of the total body (R(2) aBMD 11.7%; BMC 4.3%), radius (R(2) aBMD 23.5%; BMC 22.3%), and lumbar spine (R(2) aBMD 11.9%; BMC 10.5%) between 19 and 24 years (p bone size, whereas cortical and trabecular vBMD were 0.7% (p males was associated with a substantial catch up in aBMD and BMC in young adulthood, leaving no deficits of the lumbar spine, femoral neck, or total body at age 24 years.

  20. Mapping Bone Mineral Density Obtained by Quantitative Computed Tomography to Bone Volume Fraction

    Science.gov (United States)

    Pennline, James A.; Mulugeta, Lealem

    2017-01-01

    Methods for relating or mapping estimates of volumetric Bone Mineral Density (vBMD) obtained by Quantitative Computed Tomography to Bone Volume Fraction (BVF) are outlined mathematically. The methods are based on definitions of bone properties, cited experimental studies and regression relations derived from them for trabecular bone in the proximal femur. Using an experimental range of values in the intertrochanteric region obtained from male and female human subjects, age 18 to 49, the BVF values calculated from four different methods were compared to the experimental average and numerical range. The BVF values computed from the conversion method used data from two sources. One source provided pre bed rest vBMD values in the intertrochanteric region from 24 bed rest subject who participated in a 70 day study. Another source contained preflight vBMD values from 18 astronauts who spent 4 to 6 months on the ISS. To aid the use of a mapping from BMD to BVF, the discussion includes how to formulate them for purpose of computational modeling. An application of the conversions would be used to aid in modeling of time varying changes in vBMD as it relates to changes in BVF via bone remodeling and/or modeling.

  1. Relationship between BMD and Zn, Cu, Ca Levels in the Hair and Meal in Elderly People

    Institute of Scientific and Technical Information of China (English)

    LI Wanli; TIAN Yuhui; SONG Xiaofei; ZHANG Min; SHEN Guanxin

    2005-01-01

    The relationship between bone mineral density (BMD) and Zn, Cu, Ca levels in the meal and hair of urban and rural elderly people were studied. 470 subjects above 60 years old (urban 205 and rural 265), 178 males with an average age of 65.70±3.48 and 292 females with an average age of 65.90±4.02, were inquired. The BMD and Zn, Cu, Ca levels in the meal and hair were measured. The detected BMD in urban and rural female old people was significantly lower than that of the males; The contents of Ca and Zn in the meal of the urban females were significantly lower than those of the urban males; The Ca, Zn in the meal and Zn in the hair of the rural females were significantly lower than those of rural males (P< 0.05 or 0.01). The BMD, Ca intakes, Ca and Zn in the hair of the rural old people were significantly lower than those of the urban old people (P<0.05 or 0.01). There was a correlation between BMD with the Ca, Zn of the hair and dietary Ca,Zn, Cu or between dietary Zn with Ca, Zn in the hair and Ca, Cu intakes. The Zn, Cu and Ca levels in the meal nutrients were correlated with BMD to some degrees. Lack of Ca and Zn in the meal can cause the reduction of BMD.

  2. An analysis of BMD changes with preopertive and postoperative premenopausal breast cancer patient

    Energy Technology Data Exchange (ETDEWEB)

    KIm, Su Jin; Son, Soon Yong; Choi, Kwan Woo [Dept. of Radiology, Asan Medical Center, Seoul (Korea, Republic of); Lee, Joo Ah [Dept. of Radiation Oncology, Catholic University, Incheon St.Mary' s Hospital, Incheon (Korea, Republic of); Min, Jung Whan; Kim, Hyun Soo [Dept. of Radiology, Shingu University, Sungnam (Korea, Republic of); Ma, Sang Chull [Dept. of Radiologic Science, Shin han University, Uijeongbu (Korea, Republic of); Lee, Jong Seok; Yoo, Beong Gyu [Dept. of Radiotechnology, Wonkwang Health Science University, Iksan (Korea, Republic of)

    2014-12-15

    The purpose of this study is to provide basic data of comparing BMD (bone mineral density) value of preoperative breast cancer patient and postoperative breast cancer patient due to bone loss with radiation/chemical therapy. The participants consisted of 254 breast cancer patients with BMD after having surgery and treatment from March 2007 to September 2013. Except for 84 patients with menopause or hysterectomy and we have analysed 171 patients. The BMD value (lumbar spine and femur) of before and after treatment from PACS by dure-energy X-ray absorptiometry was analyzed. First, we found variation of entire BMD and BMD according to treatment type, and analyzed detailed correlation by using marital status, number of children, presence of feeding, age of menarche, breast cancer therapy types as variable. Data was analyzed by using SPSS for Windows Program (version 18.0). BMD was decreased 7.1% in lumbar spine, 3.1% in femur respectively (p<.01). Also there is relatively high decrement (0.067 g/cm{sup 2}) in group who had just chemotherapy in femur (p<.05). There is decrement depend on marital status, number of children, presence of feeding, age of menarche, breast cancer therapy types but there was no statistical significance. The results show that BMD was decreased after treatment in premenopausal breast cancer patient, patient who had relatively high decrement need to be included high-risk group. As a result, aggressive prevention policy would be necessary.

  3. Treatment of acromegaly increases BMD but reduces trabecular bone score: a longitudinal study.

    Science.gov (United States)

    Godang, Kristin; Olarescu, Nicoleta Cristina; Bollerslev, Jens; Heck, Ansgar

    2016-08-01

    Bone turnover is increased in acromegaly. Despite normalization of bone turnover after treatment, the risk for vertebral fractures remains increased. Gonadal status, but not BMD, is correlated with vertebral fractures. Trabecular bone score (TBS) is related to bone microarchitecture. The aim of this study is to assess the longitudinal change in TBS and BMD following treatment for acromegaly. DESIGN, SETTING, PATIENTS, INTERVENTIONS, AND MAIN OUTCOME MEASURES: This longitudinal study included 48 patients with acromegaly between 2005 and 2015. BMD, TBS, and markers for bone turnover (P1NP and CTX-1) were measured at baseline and following treatment. Following treatment, the mean TBS decreased by 3.0 (±7.0) %, whereas the BMD at the lumbar spine (LS) increased by 3.2 (±4.9) % (both Pacromegaly affects TBS and BMD at LS in different manners. The reduction of bone turnover markers predicts the increase in BMD but not the decrease in TBS. The DXA changes were more pronounced in men. Alterations in trabecular bone architecture may explain the persistent fracture risk despite the increase in BMD after disease control. © 2016 European Society of Endocrinology.

  4. Ten-year absolute risk of osteoporotic fractures according to BMD T score at menopause

    DEFF Research Database (Denmark)

    Abrahamsen, Bo; Vestergaard, Peter; Rud, Bo;

    2006-01-01

    was 10.9% as opposed to an expected risk of 5.7%. Relative risk gradients were similar to those of the recent meta-analysis. CONCLUSIONS: In healthy women, examined in the first year or two after menopause, 10-year fracture risk was higher at each level of BMD T score than expected from the model...... by Kanis et al. Inclusion of HRT users in the cohorts used may have led to higher BMD values and lower absolute fracture risk in the Kanis model. These longitudinal data can be used directly in estimating absolute fracture risk in untreated north European women from BMD at menopause....

  5. Ten-year absolute risk of osteoporotic fractures according to BMD T score at menopause

    DEFF Research Database (Denmark)

    Abrahamsen, Bo; Vestergaard, Peter; Rud, Bo

    2006-01-01

    was 10.9% as opposed to an expected risk of 5.7%. Relative risk gradients were similar to those of the recent meta-analysis. CONCLUSIONS: In healthy women, examined in the first year or two after menopause, 10-year fracture risk was higher at each level of BMD T score than expected from the model...... by Kanis et al. Inclusion of HRT users in the cohorts used may have led to higher BMD values and lower absolute fracture risk in the Kanis model. These longitudinal data can be used directly in estimating absolute fracture risk in untreated north European women from BMD at menopause....

  6. Total body and regional bone mineral densitometry (BMD) and soft tissue measurements: correlations of BMD parameter to lumbar spine and hip.

    Science.gov (United States)

    Franck, H; Munz, M

    2000-08-01

    Bone loss in men and women seems to differ according to the skeletal regions or particular areas being evaluated. Dual energy X-ray absorptiometry (DXA) is the method of choice for measuring total body and regional bone mineral area density (BMD). The aim of the study was to evaluate the importance of DXA measurements of total body in relation to lumbar spine and hip in different scan beam designs. In 300 patients, ages 43-80 years, lumbar spine, hip, total body and regional bone mineral area density, and soft tissue measurements were performed on all subjects in the supine position on a QDR 2000 using single beam (SB) and fan beam (FB). Short-term precision errors were 0.7% (SB) and 1.2% (FB) for BMD total of the total body and between 1.2% and 8.0% for soft tissue measurements. All mid-term precision errors of BMD total, right and left leg, and pelvis were below 2.0% with SB and FB, whereas precision errors of thoracic and lumbar spine varied depending on the scan mode being applied. In contrast, all mid-term precision errors of soft tissue measurements were greater (2.6-11.0%). All SB values of BMD and soft tissue measurement were significantly higher than FB values, except for BMD values of the head, thoracic spine, and pelvis. Furthermore, BMD total of the total body scan correlated significantly (P parameters with best "r"-values (0.86-0. 92) for the right and left leg in SB and FB design. In addition, there were excellent correlations (r > 0.94, P spine (or hip) and total body, being best for the subregional thorax. Our data demonstrate short-and mid-term precision errors of BMD with reproducible results for most areas in SB and FB design, whereas soft tissue measurements vary depending on the area being measured. Furthermore, there is a close relationship between BMD values of total body total and subregional parameters and lumbar spine and hip scans, respectively.

  7. Physical exercise associated with improved BMD independently of sex and vitamin D levels in young adults

    DEFF Research Database (Denmark)

    Tønnesen, Rune; Schwarz, Peter; Hovind, Peter Hambak

    2016-01-01

    PURPOSE: Young men and women accrue the majority of their bone mass in their teens and twenties, where their bone mass peaks (PBM), yet little is known about the roles of physical exercise, vitamin D levels and bone mineral density (BMD) near PBM. METHODS: To comparatively examine the effect...... of physical exercise and two vitamin D levels (insufficient s-25[OH]D 80 nmol/L) on the BMD measured at the femoral neck, total hip (bilaterally) and the lumbar spine (L2-L4) in male and female participants approaching PBM. RESULTS: The insufficient s-25[OH]D group, median...... it was equal at the lumbar spine. CONCLUSION: The BMD in young healthy adults is associated with physical exercise, independent of sex and s-25[OH]D status. A sufficient s-25[OH]D status was systematically associated with a higher BMD for all levels of exercise. For both sexes and vitamin D levels exercise...

  8. Associations between Body Composition, Hormonal and Lifestyle Factors, Bone Turnover, and BMD

    OpenAIRE

    Gourlay, Margaret L.; Hammett-Stabler, Catherine A; Renner, Jordan B.; Rubin, Janet E.

    2014-01-01

    Background The relative importance of body composition, lifestyle factors, bone turnover and hormonal factors in determining bone mineral density (BMD) is unknown. We studied younger postmenopausal women to determine whether modifiable or nonmodifiable risk factors for osteoporosis have stronger associations with BMD. Methods In multivariable linear regression models, we tested associations between non-bone body composition measures, self-reported measures of physical activity and dietary int...

  9. Cortical and trabecular bone at the radius and tibia in male and female adolescents with Down syndrome: a peripheral quantitative computed tomography (pQCT) study.

    Science.gov (United States)

    González-Agüero, A; Vicente-Rodríguez, G; Gómez-Cabello, A; Casajús, J A

    2013-03-01

    We aimed to describe the structure and strength of the tibia and radius of adolescents with Down syndrome. We observed that despite higher levels of volumetric bone mineral density in determined skeletal sites, they are at higher risk of developing osteoporotic fractures in the future due to their lower bone strength indexes. The aims of the study were to describe the cortical and trabecular volumetric bone mineral density (vBMD), bone mineral content (BMC), area, and bone strength in adolescents with Down syndrome (DS) and to compare them with adolescents without disabilities. Thirty adolescents (11 girls) with DS and 28 without disabilities (10 girls) participated in the study. Peripheral quantitative computed tomography measurements were taken at proximal and distal sites of the tibia and radius. Values of total, trabecular, and cortical BMC; vBMD; and area were obtained of each scan. Cortical thickness and endosteal and periosteal circumferences were also measured, and different bone strength indexes were calculated. Student's t tests were applied between groups. The DS group showed greater vBMD at distal radius, BMC at proximal radius, and total and cortical vBMD at proximal tibia. The non-DS group showed higher total and trabecular area at the distal radius and total, cortical, and trabecular BMC and area at distal tibia. Higher values of periosteal and endosteal circumference and bone strength were also found in non-DS group. From these results, it can be believed that even with higher vBMD in determined skeletal sites, adolescents with DS are at higher risk of suffering bone fractures due to an increased fragility by lower resistance to load bending or torsion.

  10. High Insulin Levels in KK-Ay Diabetic Mice Cause Increased Cortical Bone Mass and Impaired Trabecular Micro-Structure

    Directory of Open Access Journals (Sweden)

    Cen Fu

    2015-04-01

    Full Text Available Type 2 diabetes mellitus (T2DM is a chronic disease characterized by hyperglycemia, hyperinsulinemia and complications, including obesity and osteoporosis. Rodents have been widely used to model human T2DM and investigate its effect on the skeleton. We aimed to investigate skeletal alterations in Yellow Kuo Kondo (KK-Ay diabetic mice displaying high insulin and glucose levels. Bone mineral density (BMD, micro-architecture and bone metabolism-related genes were analyzed. The total femoral areal BMD (aBMD, cortical volumetric BMD (vBMD and thickness were significantly increased in KK-Ay mice, while the trabecular vBMD and mineralized bone volume/tissue volume (BV/TV, trabecular thickness and number were decreased compared to C57BL mice. The expression of both osteoblast-related genes, such as osteocalcin (OC, bone sialoprotein, Type I Collagen, osteonectin, RUNX2 and OSX, and osteoclast-related genes, such as TRAP and TCIRG, were up-regulated in KK-Ay mice. Correlation analyses showed that serum insulin levels were positively associated with aBMD, cortical vBMD and thickness and negatively associated with trabecular vBMD and micro-architecture. In addition, serum insulin levels were positively related to osteoblast-related and osteoclast-related gene expression. Our data suggest that high insulin levels in KK-Ay diabetic mice may increase cortical bone mass and impair trabecular micro-structure by up-regulating osteoblast-and osteoclast-related gene expression.

  11. Identification of Hip BMD Loss and Fracture Risk Markers Through Population-Based Serum Proteomics: HIP BMD LOSS & FRACTURE RISK MARKERS BY POPULATION-BASED SERUM PROTEOMICS

    Energy Technology Data Exchange (ETDEWEB)

    Nielson, Carrie M. [OHSU-PSU School of Public Health, Oregon Health & Science University, Portland, OR USA; Bone and Mineral Unit, Oregon Health & Science University, Portland, OR USA; Wiedrick, Jack [Biostatistics and Design Program, OHSU-PSU School of Public Health, Oregon Health & Science University, Portland, OR USA; Shen, Jian [Bone and Mineral Unit, Oregon Health & Science University, Portland, OR USA; Jacobs, Jon [Biological Sciences Division, Pacific Northwest National Laboratory, Richland, WA USA; Baker, Erin S. [Biological Sciences Division, Pacific Northwest National Laboratory, Richland, WA USA; Baraff, Aaron [Division of Biostatistics, Oregon Health & Science University, Portland, OR USA; Piehowski, Paul [Biological Sciences Division, Pacific Northwest National Laboratory, Richland, WA USA; Lee, Christine G. [Research Service, Portland Veterans Affairs Medical Center, Portland, OR USA; Baratt, Arie [Division of Bioinformatics and Computational Biology, Oregon Health & Science University, Portland, OR USA; Petyuk, Vladislav [Biological Sciences Division, Pacific Northwest National Laboratory, Richland, WA USA; McWeeney, Shannon [Division of Bioinformatics and Computational Biology, Oregon Health & Science University, Portland, OR USA; Lim, Jeong Youn [Division of Biostatistics, Oregon Health & Science University, Portland, OR USA; Bauer, Douglas C. [Department of Medicine, University of California, San Francisco, CA USA; Lane, Nancy E. [Department of Internal Medicine, University of California at Davis, Sacramento, CA USA; Cawthon, Peggy M. [California Pacific Medical Center Research Institute, San Francisco, CA USA; Smith, Richard D. [Biological Sciences Division, Pacific Northwest National Laboratory, Richland, WA USA; Lapidus, Jodi [Biostatistics and Design Program, OHSU-PSU School of Public Health, Oregon Health & Science University, Portland, OR USA; Orwoll, Eric S. [Bone and Mineral Unit, Oregon Health & Science University, Portland, OR USA; Department of Medicine, Oregon Health & Science University, Portland, OR USA

    2017-04-06

    Accelerated bone loss significantly increases the risk of osteoporosis and fracture. The mechanisms underlying bone loss remain incompletely understood, and there are few available biomarkers. We utilized a novel proteomics approach to identify serum peptides and proteins associated with bone loss in 1967 older men who were randomly chosen from the Osteoporotic Fracture in Men Study (MrOS study) (age ≥ 65 yrs). Men had 2-3 measures of femoral neck BMD over an average follow-up of 4.6 years. Change in BMD was estimated and then categorized into three groups: maintained BMD (n=453), expected loss (n=1185) and accelerated loss (n=237). A liquid chromatography–ion mobility separation-mass spectrometry (LC-IMS-MS) proteomics platform was used to identify and quantify peptides from serum proteins. The whole cohort was randomly divided into discovery (N= 960) and validation (N= 915) sub-cohorts. Linear regression models and a random forest approach were used to discover differentially abundant individual peptides and a proteomic signature that distinguished individuals with accelerated bone loss from those who maintained BMD. Network analyses were performed using the MetaCore knowledgebase. We identified 12 peptides that were associated with BMD loss in both discovery (P< 0.1 FDR) and replication sub-cohorts (P<0.05). Those 12 peptides mapped to the following proteins: ALS, LYVE1, RNAS1, C2, ICOSL, C163A, C7, HEMO, CD14, CERU, CRAC1 and CD59. Meta-analysis of peptidesassociated with bone loss identified 6 additional proteins including GRP78, IGF-2, SHBG, ENPP2, IBP2 and IBP6. We also identified a proteomic signature that was predictive of BMD loss with a discriminative value similar to serum bone marker carboxy-terminal collagen crosslink peptide (CTX). Interestingly, combining the proteomic signature with CTX significantly improved the ability to discriminate men with accelerated loss. In summary, we have identified potential new biomarkers for bone loss that provide

  12. BMD measurements of the spine derived from sagittal reformations of contrast-enhanced MDCT without dedicated software

    Energy Technology Data Exchange (ETDEWEB)

    Baum, Thomas, E-mail: thbaum@gmx.de [Institut fuer Roentgendiagnostik, Klinikum rechts der Isar, Technische Universitaet Muenchen, Ismaninger Str. 22, 81675 Muenchen (Germany); Mueller, Dirk, E-mail: dirk.mueller@roe.med.tum.de [Institut fuer Roentgendiagnostik, Klinikum rechts der Isar, Technische Universitaet Muenchen, Ismaninger Str. 22, 81675 Muenchen (Germany); Dobritz, Martin, E-mail: dobritz@roe.med.tum.de [Institut fuer Roentgendiagnostik, Klinikum rechts der Isar, Technische Universitaet Muenchen, Ismaninger Str. 22, 81675 Muenchen (Germany); Rummeny, Ernst J., E-mail: institut@roe.med.tum.de [Institut fuer Roentgendiagnostik, Klinikum rechts der Isar, Technische Universitaet Muenchen, Ismaninger Str. 22, 81675 Muenchen (Germany); Link, Thomas M., E-mail: thomas.link@radiology.ucsf.edu [Musculoskeletal and Quantitative Imaging Research, Department of Radiology and Biomedical Imaging, University of California San Francisco, 185 Berry Street, Suite 350, San Francisco, CA 94107 (United States); Bauer, Jan S., E-mail: jsb@roe.med.tum.de [Institut fuer Roentgendiagnostik, Klinikum rechts der Isar, Technische Universitaet Muenchen, Ismaninger Str. 22, 81675 Muenchen (Germany)

    2011-11-15

    Purpose: To assess QCT equivalent BMD of the lumbar spine in sagittal reformations of routine abdominal contrast-enhanced MDCT with simple PACS measurement tools and to apply this method to MDCT datasets for differentiating patients with and without osteoporotic vertebral fractures. Materials and methods: Eight postmenopausal women (65 {+-} 5years) underwent standard QCT to assess BMD of L1-L3. Afterwards routine abdominal contrast-enhanced MDCT images of these women were obtained and apparent BMD of L1-L3 was measured using the sagittal reformations. The MDCT-to-QCT conversion equation for BMD was calculated with linear regression analysis. The conversion equation was applied to vertebral BMD datasets (L1-L3) of 75 postmenopausal women (66 {+-} 4years). Seventeen of the 75 patients had osteoporotic vertebral fractures. Results: BMD values of contrast-enhanced MDCT were on average 56 mg/ml higher than those of standard QCT. A correlation coefficient of r = 0.94 (p < 0.05) was calculated for the BMD values of MDCT and standard QCT with the conversion equation BMD{sub QCT} = 0.69 x BMD{sub MDCT} - 11 mg/ml. Accordingly converted BMD values of patients with vertebral fractures were significantly lower than those of patients without vertebral fractures (69 mg/ml vs. 85 mg/ml; p < 0.05). Using ROC analysis to differentiate patients with and without vertebral fractures, AUC = 0.72 was obtained for converted BMD values (p < 0.05). Short- and long-term reproducibility errors for BMD measurements in the sagittal reformations amounted 2.09% and 7.70%, respectively. Conclusion: BMD measurements of the spine could be computed in sagittal reformations of routine abdominal contrast-enhanced MDCT with minimal technical and time effort. Using the conversion equation, the acquired BMD data could differentiate patients with and without osteoporotic vertebral fractures.

  13. Quantitative Techniques in Volumetric Analysis

    Science.gov (United States)

    Zimmerman, John; Jacobsen, Jerrold J.

    1996-12-01

    Quantitative Techniques in Volumetric Analysis is a visual library of techniques used in making volumetric measurements. This 40-minute VHS videotape is designed as a resource for introducing students to proper volumetric methods and procedures. The entire tape, or relevant segments of the tape, can also be used to review procedures used in subsequent experiments that rely on the traditional art of quantitative analysis laboratory practice. The techniques included are: Quantitative transfer of a solid with a weighing spoon Quantitative transfer of a solid with a finger held weighing bottle Quantitative transfer of a solid with a paper strap held bottle Quantitative transfer of a solid with a spatula Examples of common quantitative weighing errors Quantitative transfer of a solid from dish to beaker to volumetric flask Quantitative transfer of a solid from dish to volumetric flask Volumetric transfer pipet A complete acid-base titration Hand technique variations The conventional view of contemporary quantitative chemical measurement tends to focus on instrumental systems, computers, and robotics. In this view, the analyst is relegated to placing standards and samples on a tray. A robotic arm delivers a sample to the analysis center, while a computer controls the analysis conditions and records the results. In spite of this, it is rare to find an analysis process that does not rely on some aspect of more traditional quantitative analysis techniques, such as careful dilution to the mark of a volumetric flask. Figure 2. Transfer of a solid with a spatula. Clearly, errors in a classical step will affect the quality of the final analysis. Because of this, it is still important for students to master the key elements of the traditional art of quantitative chemical analysis laboratory practice. Some aspects of chemical analysis, like careful rinsing to insure quantitative transfer, are often an automated part of an instrumental process that must be understood by the

  14. Test Facility for Volumetric Absorber

    Energy Technology Data Exchange (ETDEWEB)

    Ebert, M.; Dibowski, G.; Pfander, M.; Sack, J. P.; Schwarzbozl, P.; Ulmer, S.

    2006-07-01

    Long-time testing of volumetric absorber modules is an inevitable measure to gain the experience and reliability required for the commercialization of the open volumetric receiver technology. While solar tower test facilities are necessary for performance measurements of complete volumetric receivers, the long-term stability of individual components can be tested in less expensive test setups. For the qualification of the aging effects of operating cycles on single elements of new absorber materials and designs, a test facility was developed and constructed in the framework of the KOSMOSOL project. In order to provide the concentrated solar radiation level, the absorber test facility is integrated into a parabolic dish system at the Plataforma Solar de Almeria (PSA) in Spain. Several new designs of ceramic absorbers were developed and tested during the last months. (Author)

  15. Calcium and vitamin D supplementation increases spinal BMD in healthy, postmenopausal women

    DEFF Research Database (Denmark)

    Baeksgaard, L; Andersen, K P; Hyldstrup, Lars

    1998-01-01

    We undertook a double-masked, randomized, placebo-controlled trial to evaluate the effect of a calcium and vitamin D supplement and a calcium supplement plus multivitamins on bone loss at the hip, spine and forearm. The study was performed in 240 healthy women, 58-67 years of age. Duration...... of treatment was 2 years. Bone mineral density (BMD) was measured at the lumbar spine, hip and forearm. A dietary questionnaire was administered twice during the study and revealed a fairly good calcium and vitamin D intake (919 mg calcium/day; 3.8 micrograms vitamin D/day). An increase in lumbar spine BMD....... Together with significant changes in serum calcium and serum parathyroid hormone, this indicates that a long-term calcium and vitamin supplement of 1 g elementary calcium (calcium carbonate) and 14 micrograms vitamin D3 increases intestinal calcium absorption. A positive effect on BMD was demonstrated...

  16. Using Fluorescence in situ Hybridization to Identify DMD/BMD Deletion Carriers

    Institute of Scientific and Technical Information of China (English)

    Ren-li WANG; Yan-ping XIAO; Xiu-rong JIANG

    2003-01-01

    Objective To identify the deletions in Duchenne/Becker muscular dystrophy (DMD/BMD) by using fluorescence in situ hybridization (FISH) Methods The exon-specific cosmid DNA probes (representing 18 exons) were used to perform one-color FISH on metaphase and interphase preparations. The peripheral blood samples from 9 normal people (4 males and 5 females) and 5 females from independent deletion DMD/BMD families, as well as 2 amniotic fluid specimens and 2 chorionic villus samples (CVS) from normal pregnant females were analyzed.Results 72%~100% of peripheral blood lymphocyte metaphases or interphases, 60%~70% of amniocyte interphases, and 95~99% of chorionic villus cell interphases showed expected signals. One suspected female was identified as deletion carriers and two were excluded.Conclusion FISH in combination with other available techniques allows efficient screening of DMD/BMD deletion carriers, which also lay the ground work for prenatal diagnosis for potential fetal carriers.

  17. Phantom-less QCT BMD system as screening tool for osteoporosis without additional radiation

    Energy Technology Data Exchange (ETDEWEB)

    Mueller, Dirk K., E-mail: dirk.mueller@philips.com [Philips GmbH, Healthcare Division, Luebeckertordamm 5, 20099 Hamburg (Germany); Kutscherenko, Alex; Bartel, Hans [Kaiserswerther Diakonie, Florence-Nightingale Hospital, Kreuzbergstrasse 79, 40489 Duesseldorf (Germany); Vlassenbroek, Alain [Philips Healthcare, Bruxelles, Rue des Deux Gares 80, 1070 Bruxelles (Belgium); Ourednicek, Petr [Philips Czech Republic, Safrankova 1, 15500 Prague 5 (Czech Republic); Erckenbrecht, Joachim [Kaiserswerther Diakonie, Florence-Nightingale Hospital, Kreuzbergstrasse 79, 40489 Duesseldorf (Germany)

    2011-09-15

    Purpose: Phantom-less bone mineral density (PLBMD) systems are easily integrated into the CT workflow for non-dedicated Quantitative CT (QCT) BMD measurements in thoracic and abdominal scans. This in vivo retrospective study aims to determine accuracy and precision of the PLBMD option located on the Extended Brilliance Workspace (Philips Medical Systems, Cleveland, OH, US) from both cross-sectional and longitudinal image data. Materials and methods: The cross-sectional comparison with phantom-based QCT BMD was performed for 82 patients (61 female, 21 male) with a mean age of (63.0 {+-} 11.8 SD) years on 197 vertebrae. This was followed by an interobserver variability analysis on 71 vertebrae. The longitudinal PLBMD study was carried out on 45 vertebrae from 10 patients (5 female, 5 male) with a mean age of (64.4 {+-} 11.5 SD) years. They were re-scanned with standardized scan and contrast-injection protocols within a mean and median of (33 {+-} 41 SD) and 8 days, respectively. All CT scans were acquired on an Mx8000 Quad (Philips) at Florence-Nightingale Hospital, Kaiserswerth, Germany, in a spiral acquisition mode. Results: A negligible BMD bias of -0.9 mg/cm{sup 3} for the PLBMD option was observed with respect to phantom-based QCT BMD. Applying CT number matching of muscle and fat ROIs, the analysis of cross-sectional interobserver and of longitudinal variability yielded precision values of 3.1 mg/cm{sup 3} (CV% = 4.0) and 4.2 mg/cm{sup 3} (CV% = 5.3), respectively. Conclusion: Although the precision is inferior to phantom-based BMD systems, PLBMD is a robust clinical utility for the detection of lowered BMD in a large patient population. This can be achieved without additional radiation exposure from non-contrasted CT scans, to perform an ancillary diagnosis of osteopenia or osteoporosis.

  18. Alendronate increases BMD at appendicular and axial skeletons in patients with established osteoporosis

    Directory of Open Access Journals (Sweden)

    Au Szeki

    2007-05-01

    Full Text Available Abstract Background To identify high-risk patients and provide pharmacological treatment is one of the effective approaches in prevention of osteoporotic fractures. This study investigated the effect of 12-month Alendronate treatment on bone mineral density (BMD and bone turnover biochemical markers in postmenopausal women with one or more non-traumatic fractures, i.e. patients with established osteoporosis. Methods A total of 118 Hong Kong postmenopausal Chinese women aged 50 to 75 with low-energy fracture at distal radius (Colles' fracture were recruited for BMD measurement at lumbar spine and non-dominant hip using Dual-Energy X-ray Absorptiometry (DXA. 47 women with BMD T-score below -2 SD at either side were identified as patients with established osteoporosis and then randomized into Alendronate group (n = 22 and placebo control group (n = 25 for BMD measurement at spine and hip using DXA and distal radius of the non-fracture side by peripheral quantitative computed tomography (pQCT, and bone turnover markers, including bone forming alkaline phosphatase (BALP and bone resorbing urinary Deoxypyridinoline (DPD. All measurements were repeated at 6 and 12 months. Results Alendronate treatment significantly increased BMD, more in weight-bearing skeletons (5.1% at spine and 2.5% at hip than in non-weight bearing skeleton (0.9% at distal radius after 12 months treatment. Spine T-score was significant improved in Alendronate group (p Conclusion 12 months Alendronate treatment was effective to increase BMD at both axial and appendicular skeletons in postmenopausal women with established osteoporosis.

  19. Identification of a Linkage Disequilibrium Block in Chromosome 1q Associated With BMD in Premenopausal White Women

    OpenAIRE

    Ichikawa, Shoji; Koller, Daniel L.; Curry, Leah R.; Lai, Dongbing; Xuei, Xiaoling; Pugh, Elizabeth W; Tsai, Ya-Yu; Doheny, Kimberly F.; Edenberg, Howard J.; Hui, Siu L.; Foroud, Tatiana; Peacock, Munro; Econs, Michael J.

    2008-01-01

    Osteoporosis is a complex disease with both genetic and environmental risk factors. A major determinant of osteoporotic fractures is peak BMD obtained during young adulthood. We previously reported linkage of chromosome 1q (LOD = 4.3) with variation in spinal areal BMD in healthy premenopausal white women. In this study, we used a two-stage genotyping approach to identify genes in the linked region that contributed to the variation of femoral neck and lumbar spine areal BMD. In the first stag...

  20. Assessment of volumetric bone mineral density of the femoral neck in postmenopausal women with and without vertebral fractures using quantitative multi-slice CT

    Institute of Scientific and Technical Information of China (English)

    Sheng-yong WU; Hui-hui JIA; Didier HANS; Jing LAN; Li-ying WANG; Jing-xue LI; Yue-zeng CAI

    2009-01-01

    Objective: To demonstrate the validity and reliability of volumetric quantitative computed tomography (vQCT) with multi-slice computed tomography (MSCT) and dual energy X-ray absorptiometry (DXA) for hip bone mineral density (BMD) measurements, and to compare the differences between the two techniques in discriminating postmenopausal women with osteoporosis-related vertebral fractures from those without. Methods: Ninety subjects were enrolled and divided into three groups based on the BMD values of the lumbar spine and/or the femoral neck by DXA. Groups 1 and 2 consisted of postmenopausal women with BMD changes <-2SD, with and without radiographically confirmed vertebral fracture (n=11 and 33, respectively).Group 3 comprised normal controls with BMD changes ≥-1SD (n=46). Post-MSCT (GE, LightSpeed16) scan reconstructed images of the abdominal-pelvic region, 1.25 mm thick per slice, were processed by OsteoCAD software to calculate the following parameters: volumetric BMD values of trabecular bone (TRAB), cortical bone (CORT), and integral bone (INTGL) of the left femoral neck, femoral neck axis length (NAL), and minimum cross-section area (mCSA). DXA BMD measurements of the lumbar spine (AP-SPINE) and the left femoral neck (NECK) also were performed for each subject. Results: The values of all seven parameters were significantly lower in subjects of Groups 1 and 2 than in normal postmenopausal women (P<0.05, respectively).Comparing Groups 1 and 2, 3D-TRAB and 3D-INTGL were significantly lower in postmenopausal women with vertebral fracture(s) [(109.8±9.61) and (243.3±33.0) mg/cm3, respectively] than in those without [(148.9±7.47) and (285.4±17.8) mg/cm3,respectively] (P<0.05, respectively), but no significant differences were evident in AP-SPINE or NECK BMD. Conclusion: the femoral neck-derived volumetric BMD parameters using vQCT appeared better than the DXA-derived ones in discriminating osteoporotic postmenopausal women with vertebral fractures from

  1. BMD PREDICTION OF DEATH IS ENCAPSULATED BY THE MORPHOLOGICAL ATHEROSCLEROSIS CALCIFICATION DISTRIBUTION (MACD) INDEX

    DEFF Research Database (Denmark)

    Ganz, Melanie; Nielsen, Mads; Karsdal, Morten

    2009-01-01

    .3±0.3 years and of which CVD, cancer, and all cause deaths were recorded. The spine BMD and aortic calcification markers, AC24 and the recently proposed Morphological Atherosclerosis Calcification Distribution (MACD) index, were quantified from DXA scans and lateral X-rays respectively. The MACD...

  2. Pediatrics: Measuring pediatric BMD-the bar raised but the glass half full.

    Science.gov (United States)

    Langman, Craig B

    2011-11-22

    Extensive reference data sets of pediatric bone density measurements are now available, together with equations to translate BMD into relevant Z-scores and correct for abnormal stature. So now is the right time to ask: are you thinking about bone density in children correctly?

  3. Application of Benchmark Dose (BMD) in Estimating Biological Exposure Limit (BEL) to Cadmium

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    Objective To estimate the biological exposure limit (BEL) using benchmark dose (BMD) based on two sets of data from occupational epidemiology. Methods Cadmium-exposed workers were selected from a cadmium smelting factory and a zinc product factory. Doctors, nurses or shop assistants living in the same area served as a control group. Urinary cadmium (UCd) was used as an exposure biomarker and urinary β2-microgloburin (B2M), N-acetyl-β-D-glucosaminidase (NAG) and albumin (ALB) as effect biomarkers. All urine parameters were adjusted by urinary creatinine. Software of BMDS (Version 1.3.2, EPA.U.S.A) was used to calculate BMD. Results The cut-off point (abnormal values) was determined based on the upper limit of 95% of effect biomarkers in control group. There was a significant dose response relationship between the effect biomarkers (urinary B2M, NAG, and ALB) and exposure biomarker (UCd). BEL value was 5 μg/g creatinine for UB2M as an effect biomarker, consistent with the recommendation of WHO. BEL could be estimated by using the method of BMD. BEL value was 3 μg/g creatinine for UNAG as an effect biomarker. The more sensitive the used biomarker is, the more occupational population will be protected. Conclusion BMD can be used in estimating the biological exposure limit (BEL). UNAG is a sensitive biomarker for estimating BEL after cadmium exposure.

  4. Navy Aegis Ballistic Missile Defense (BMD) Program: Background and Issues for Congress

    Science.gov (United States)

    2016-10-25

    developments in Australia, Japan , and South Korea. 93 Justin Doubleday, “MDA Looking to Integrate European Allies into Missile Defense Architecture ...12 Japan ................................................................................................................................. 12 Other...building, or are planning to build Aegis-equipped ships include Japan , South Korea, Australia, Spain, and Norway.2 Aegis BMD System3 Aegis ships

  5. Bone lead (Pb) content at the tibia is associated with thinner distal tibia cortices and lower volumetric bone density in postmenopausal women.

    Science.gov (United States)

    Wong, Andy K O; Beattie, Karen A; Bhargava, Aakash; Cheung, Marco; Webber, Colin E; Chettle, David R; Papaioannou, Alexandra; Adachi, Jonathan D

    2015-10-01

    Conflicting evidence suggests that bone lead or blood lead may reduce areal bone mineral density (BMD). Little is known about how lead at either compartment affects bone structure. This study examined postmenopausal women (N=38, mean age 76 ± 8, body mass index (BMI): 26.74 ± 4.26 kg/m(2)) within the Hamilton cohort of the Canadian Multicentre Osteoporosis Study (CaMos), measuring bone lead at 66% of the non-dominant leg and at the calcaneus using (109)Cadmium X-ray fluorescence. Volumetric BMD and structural parameters were obtained from peripheral quantitative computed tomography images (200 μm in-plane resolution, 2.3 ± 0.5mm slice thickness) of the same 66% site and of the distal 4% site of the tibia length. Blood lead was measured using atomic absorption spectrometry and blood-to-bone lead partition coefficients (PBB, log ratio) were computed. Multivariable linear regression examined each of bone lead at the 66% tibia, calcaneus, blood lead and PBB as related to each of volumetric BMD and structural parameters, adjusting for age and BMI, diabetes or antiresorptive therapy. Regression coefficients were reported along with 95% confidence intervals. Higher amounts of bone lead at the tibia were associated with thinner distal tibia cortices (-0.972 (-1.882, -0.061) per 100 μg Pb/g of bone mineral) and integral volumetric BMD (-3.05 (-6.05, -0.05) per μg Pb/g of bone mineral). A higher PBB was associated with larger trabecular separation (0.115 (0.053, 0.178)), lower trabecular volumetric BMD (-26.83 (-50.37, -3.29)) and trabecular number (-0.08 (-0.14, -0.02)), per 100 μg Pb/g of bone mineral after adjusting for age and BMI, and remained significant while accounting for diabetes or use of antiresorptives. Total lead exposure activities related to bone lead at the calcaneus (8.29 (0.11, 16.48)) and remained significant after age and antiresorptives-adjustment. Lead accumulated in bone can have a mild insult on bone structure; but greater partitioning of lead

  6. Relationship between Mandibular BMD and Bone Turnover Markers in Osteoporosis Diagnosis

    Directory of Open Access Journals (Sweden)

    SM Eshaghi

    2008-11-01

    Full Text Available "nBackground: The purpose of the present study was to determine mandible bone mineral density and evaluate its correlation with central BMD and bone turnover."nMethods: Two hundred and seven postmenopausal women were enrolled in this cross-sectional study. After receiving the tes­timonials, questionnaires were completed and physical exams were done. For all participants central BMD was measured through DXA method. In each women periapical radiography performed in two regions of mandible. The plain x-ray films were scanned using a standard film digitizer and standardized in size and intensity using a calibration step wedge phantom. The phantom was placed upper site in film cover. After the film digitized, the developed Matlab software was used to image proc­essing."nResults: Mean age and body mass index of participants were 54.6±6.3 years and 28.57±4.9 kg/m2 respectively. Prevalence of osteoporosis and osteopenia in one of regions in central DXA were 17.4% and 48.2% respectively. There was strong cor­relation between mandible and total femur BMD (P= 0.001, r= 0.80.In osteoporotic patients bone loss in mandible BMD was more than central DXA (P= 0.02."nConclusion: The main advantage of the proposed mandible BMD is to help clinicians make more accurate evaluation of Bone loss. Based on developed the suggested system a routine dental X-ray could be used to screen for bone loss.

  7. Isolated GH deficiency due to a GHRH receptor mutation causes hip joint problems and genu valgum, and reduces size but not density of trabecular and mixed bone.

    Science.gov (United States)

    Epitácio-Pereira, Carlos C; Silva, Gabriella M F; Salvatori, Roberto; Santana, João A M; Pereira, Francisco A; Gois-Junior, Miburge B; Britto, Allan V O; Oliveira, Carla R P; Souza, Anita H O; Santos, Elenilde G; Campos, Viviane C; Pereira, Rossana M C; Valença, Eugênia H O; Barbosa, Rita A A; Farias, Maria Isabel T; de Paula, Francisco J A; Ribeiro, Taisa V; Oliveira, Mario C P; Aguiar-Oliveira, Manuel H

    2013-11-01

    The GH/IGF-I axis is important for bone growth, but its effects on joint function are not completely understood. Adult-onset GH-deficient individuals have often reduced bone mineral density (BMD). However, there are limited data on BMD in adult patients with untreated congenital isolated GH-deficient (IGHD). We have shown that adult IGHD individuals from the Itabaianinha, homozygous for the c.57+1G>A GHRHR mutation, have reduced bone stiffness, but BMD and joint status in this cohort are unknown. The goal is to study BMD, joint function, and osteoarthritis score in previously untreated IGHD adults harboring the c.57+1G>A GHRHR mutation. This is a cross-sectional study. Areal BMD by dual-energy X-ray absorptiometry was measured in 25 IGHD and 23 controls (CO). Volumetric BMD (vBMD) was calculated at the lumbar spine and total hip. Joint function was assessed by goniometry of elbow, hips, and knees. X-rays were used to measure the anatomic axis of knee and the severity of osteoarthritis, using a classification for osteophytes (OP) and joint space narrowing (JSN). Genu valgum was more prevalent in IGHD than CO. The osteoarthritis knees OP score was similar in both groups, and knees JSN score showed a trend to be higher in IGHD. The hips OP score and JSN score were higher in IGHD. Areal BMD was lower in IGHD than CO, but vBMD was similar in the two groups. Range of motion was similar in elbow, knee, and hip in IGHD and CO. Untreated congenital IGHD due to a GHRHR mutation causes hip joint problems and genu valgum, without apparent clinical significance, reduces bone size, but does not reduce vBMD of the lumbar spine and hip.

  8. Factors Predicting Bone Mineral Density (BMD Changes in Young Women over A One-year Study:Changes in Body Weight and Bone Metabolic Markers during the Menstrual Cycle and Their Effects on BMD

    Directory of Open Access Journals (Sweden)

    Iida,Tadayuki

    2012-08-01

    Full Text Available Currently, 26% of Japanese women in their twenties are under weight, and therefore at risk of developing various metabolic abnormalities due to an inadequate nutrient intake, which in turn affects the acquisition of a peak bone mineral density (BMD. In this study, we aimed to clarify the effects of menstrual cycle-related changes in body weight and bone metabolic marker levels on the BMD changes. The subjects were 42 women (19.6±0.8 years. The levels of osteocalcin (OC, BAP, s-NTx, u-DPD, and E2 in the menstrual and ovulatory phases were measured. The associations between dependent variables (BMD changes/year in the lumbar spine, femur, femoral neck and explanatory variables (body weight changes/year, the levels of OC, BAP, s-NTx, u-DPD were evaluated using multiple regression analysis. Analysis of the correlations between the changes in bone metabolic markers and changes in BMD showed a correlation between the OC level in the menstrual phase and changes in the BMD of the entire femur, suggesting that a high OC level protects against BMD reduction, probably by promoting osteoblast activity, and that bone formation activity suppresses the decrease in BMD. These results suggest that, to predict BMD changes from bone metabolic markers in young women, it is necessary to measure OC levels in the menstrual phase.

  9. BMD in elite female triathletes is related to isokinetic peak torque without any association to sex hormone concentrations

    DEFF Research Database (Denmark)

    Wulff Helge, E; Melin, Anna Katarina; Waaddegaard, M

    2012-01-01

    Female endurance athletes suffering from low energy availability and reproductive hormonal disorders are at risk of low BMD. Muscle forces acting on bone may have a reverse site-specific effect. Therefore we wanted to test how BMD in female elite triathletes was associated to isokinetic peak torque...

  10. Identification of a linkage disequilibrium block in chromosome 1q associated with BMD in premenopausal white women.

    Science.gov (United States)

    Ichikawa, Shoji; Koller, Daniel L; Curry, Leah R; Lai, Dongbing; Xuei, Xiaoling; Pugh, Elizabeth W; Tsai, Ya-Yu; Doheny, Kimberly F; Edenberg, Howard J; Hui, Siu L; Foroud, Tatiana; Peacock, Munro; Econs, Michael J

    2008-10-01

    Osteoporosis is a complex disease with both genetic and environmental risk factors. A major determinant of osteoporotic fractures is peak BMD obtained during young adulthood. We previously reported linkage of chromosome 1q (LOD = 4.3) with variation in spinal areal BMD in healthy premenopausal white women. In this study, we used a two-stage genotyping approach to identify genes in the linked region that contributed to the variation of femoral neck and lumbar spine areal BMD. In the first stage, 654 SNPs across the linked region were genotyped in a sample of 1309 premenopausal white women. The most significant evidence of association for lumbar spine (p = 1.3 x 10(-6)) was found with rs1127091 in the GATAD2B gene. In the second stage, 52 SNPs around this candidate gene were genotyped in an expanded sample of 1692 white women. Significant evidence of association with spinal BMD (p 2.5% of the variation in spinal BMD in these women. The 230-kb LD block contains 11 genes, but because of the extensive LD, the specific gene(s) contributing to the variation in BMD could not be determined. In conclusion, the significant association between spinal BMD and SNPs in the 230-kb LD block in chromosome 1q indicates that genetic factor(s) in this block plays an important role in peak spinal BMD in healthy premenopausal white women.

  11. BMD in elite female triathletes is related to isokinetic peak torque without any association to sex hormone concentrations

    DEFF Research Database (Denmark)

    Helge, Eva Wulff; Melin, Anna; Waaddegaard, Mette

    2012-01-01

    Female endurance athletes suffering from low energy availability and reproductive hormonal disorders are at risk of low BMD. Muscle forces acting on bone may have a reverse site-specific effect. Therefore we wanted to test how BMD in female elite triathletes was associated to isokinetic peak torq...

  12. Osteoporosis in ankylosing spondylitis - prevalence, risk factors and methods of assessment

    Science.gov (United States)

    2012-01-01

    Introduction Osteoporosis can be a complication of ankylosing spondylitis (AS), but diagnosing spinal osteoporosis can be difficult since pathologic new bone formation interferes with the assessment of the bone mineral density (BMD). The aims of the current study were to investigate prevalence and risk factors for reduced BMD in a Swedish cohort of AS patients, and to examine how progressive ankylosis influences BMD with the use of dual-energy x-ray absorptiometry (DXA) of the lumbar spine in different projections. Methods Methods of assessment were questionnaires, back mobility tests, blood samples, lateral spine radiographs for syndesmophyte grading (mSASSS), DXA of the hip, radius and lumbar spine in anteroposterior (AP) and lateral projections with estimation of volumetric BMD (vBMD). Results AS patients (modified New York criteria), 87 women and 117 men, mean age 50 ± 13 years and disease duration 15 ± 11 years were included. According to World Health Organization (WHO) criteria 21% osteoporosis and 44% osteopenia was diagnosed in patients > = 50 years. Under age 50 BMD below expected range for age was found in 5%. Interestingly lateral lumbar DXA showed significantly lower BMD and revealed significantly more cases with osteoporosis as compared with AP DXA. Lumbar vBMD was not different between sexes, but women had significantly more lumbar osteoporosis measured with AP DXA (P Ankylosing Spondylitis Metrology Index (BASMI), inflammatory parameters and low body mass index (BMI). Increasing mSASSS correlated significantly with decreasing lateral and volumetric lumbar BMD, while AP lumbar BMD showed tendency to increase. Conclusions Osteoporosis and osteopenia is common in AS and associated with high disease burden. Lateral and volumetric lumbar DXA are more sensitive than AP DXA in detecting osteoporosis and are less affected by syndesmophyte formation. PMID:22569245

  13. Volumetric Three-Dimensional Display Systems

    Science.gov (United States)

    Blundell, Barry G.; Schwarz, Adam J.

    2000-03-01

    A comprehensive study of approaches to three-dimensional visualization by volumetric display systems This groundbreaking volume provides an unbiased and in-depth discussion on a broad range of volumetric three-dimensional display systems. It examines the history, development, design, and future of these displays, and considers their potential for application to key areas in which visualization plays a major role. Drawing substantially on material that was previously unpublished or available only in patent form, the authors establish the first comprehensive technical and mathematical formalization of the field, and examine a number of different volumetric architectures. System level design strategies are presented, from which proposals for the next generation of high-definition predictable volumetric systems are developed. To ensure that researchers will benefit from work already completed, they provide: * Descriptions of several recent volumetric display systems prepared from material supplied by the teams that created them * An abstract volumetric display system design paradigm * An historical summary of 90 years of development in volumetric display system technology * An assessment of the strengths and weaknesses of many of the systems proposed to date * A unified presentation of the underlying principles of volumetric display systems * A comprehensive bibliography Beautifully supplemented with 17 color plates that illustrate volumetric images and prototype displays, Volumetric Three-Dimensional Display Systems is an indispensable resource for professionals in imaging systems development, scientific visualization, medical imaging, computer graphics, aerospace, military planning, and CAD/CAE.

  14. European bone mineral density loci are also associated with BMD in East-Asian populations.

    Directory of Open Access Journals (Sweden)

    Unnur Styrkarsdottir

    Full Text Available Most genome-wide association (GWA studies have focused on populations of European ancestry with limited assessment of the influence of the sequence variants on populations of other ethnicities. To determine whether markers that we have recently shown to associate with Bone Mineral Density (BMD in Europeans also associate with BMD in East-Asians we analysed 50 markers from 23 genomic loci in samples from Korea (n = 1,397 and two Chinese Hong Kong sample sets (n = 3,869 and n = 785. Through this effort we identified fourteen loci that associated with BMD in East-Asian samples using a false discovery rate (FDR of 0.05; 1p36 (ZBTB40, P = 4.3×10(-9, 1p31 (GPR177, P = 0.00012, 3p22 (CTNNB1, P = 0.00013, 4q22 (MEPE, P = 0.0026, 5q14 (MEF2C, P = 1.3×10(-5, 6q25 (ESR1, P = 0.0011, 7p14 (STARD3NL, P = 0.00025, 7q21 (FLJ42280, P = 0.00017, 8q24 (TNFRSF11B, P = 3.4×10(-5, 11p15 (SOX6, P = 0.00033, 11q13 (LRP5, P = 0.0033, 13q14 (TNFSF11, P = 7.5×10(-5, 16q24 (FOXL1, P = 0.0010 and 17q21 (SOST, P = 0.015. Our study marks an early effort towards the challenge of cataloguing bone density variants shared by many ethnicities by testing BMD variants that have been established in Europeans, in East-Asians.

  15. European bone mineral density loci are also associated with BMD in East-Asian populations.

    Science.gov (United States)

    Styrkarsdottir, Unnur; Halldorsson, Bjarni V; Gudbjartsson, Daniel F; Tang, Nelson L S; Koh, Jung-Min; Xiao, Su-mei; Kwok, Timothy C Y; Kim, Ghi Su; Chan, Juliana C N; Cherny, Stacey; Lee, Seung Hun; Kwok, Anthony; Ho, Suzanne; Gretarsdottir, Solveig; Kostic, Jelena Pop; Palsson, Stefan Th; Sigurdsson, Gunnar; Sham, Pak C; Kim, Beom-Jun; Kung, Annie W C; Kim, Shin-Yoon; Woo, Jean; Leung, Ping-C; Kong, Augustine; Thorsteinsdottir, Unnur; Stefansson, Kari

    2010-10-07

    Most genome-wide association (GWA) studies have focused on populations of European ancestry with limited assessment of the influence of the sequence variants on populations of other ethnicities. To determine whether markers that we have recently shown to associate with Bone Mineral Density (BMD) in Europeans also associate with BMD in East-Asians we analysed 50 markers from 23 genomic loci in samples from Korea (n = 1,397) and two Chinese Hong Kong sample sets (n = 3,869 and n = 785). Through this effort we identified fourteen loci that associated with BMD in East-Asian samples using a false discovery rate (FDR) of 0.05; 1p36 (ZBTB40, P = 4.3×10(-9)), 1p31 (GPR177, P = 0.00012), 3p22 (CTNNB1, P = 0.00013), 4q22 (MEPE, P = 0.0026), 5q14 (MEF2C, P = 1.3×10(-5)), 6q25 (ESR1, P = 0.0011), 7p14 (STARD3NL, P = 0.00025), 7q21 (FLJ42280, P = 0.00017), 8q24 (TNFRSF11B, P = 3.4×10(-5)), 11p15 (SOX6, P = 0.00033), 11q13 (LRP5, P = 0.0033), 13q14 (TNFSF11, P = 7.5×10(-5)), 16q24 (FOXL1, P = 0.0010) and 17q21 (SOST, P = 0.015). Our study marks an early effort towards the challenge of cataloguing bone density variants shared by many ethnicities by testing BMD variants that have been established in Europeans, in East-Asians.

  16. Elements of a BMD C3 (Command, Control and Communications) V & H Program,

    Science.gov (United States)

    1983-03-14

    function of yield 0 The vulnerability of the network to cratering and ground motion effects * the duration of temporary disruption in any link which can be...Long Distance Links 0 be assured? --Satellites --Aircraft/Airborne Relays e RF Propagation --Reflection By Perturbed D-layer -- Meteor Scatter...existing data base should be adequate. Another technology which might be examined for BMD applications is meteor burst communications. Nuclear

  17. Proposing an adaptive mutation to improve XCSF performance to classify ADHD and BMD patients

    Science.gov (United States)

    Sadatnezhad, Khadijeh; Boostani, Reza; Ghanizadeh, Ahmad

    2010-12-01

    There is extensive overlap of clinical symptoms observed among children with bipolar mood disorder (BMD) and those with attention deficit hyperactivity disorder (ADHD). Thus, diagnosis according to clinical symptoms cannot be very accurate. It is therefore desirable to develop quantitative criteria for automatic discrimination between these disorders. This study is aimed at designing an efficient decision maker to accurately classify ADHD and BMD patients by analyzing their electroencephalogram (EEG) signals. In this study, 22 channels of EEGs have been recorded from 21 subjects with ADHD and 22 individuals with BMD. Several informative features, such as fractal dimension, band power and autoregressive coefficients, were extracted from the recorded signals. Considering the multimodal overlapping distribution of the obtained features, linear discriminant analysis (LDA) was used to reduce the input dimension in a more separable space to make it more appropriate for the proposed classifier. A piecewise linear classifier based on the extended classifier system for function approximation (XCSF) was modified by developing an adaptive mutation rate, which was proportional to the genotypic content of best individuals and their fitness in each generation. The proposed operator controlled the trade-off between exploration and exploitation while maintaining the diversity in the classifier's population to avoid premature convergence. To assess the effectiveness of the proposed scheme, the extracted features were applied to support vector machine, LDA, nearest neighbor and XCSF classifiers. To evaluate the method, a noisy environment was simulated with different noise amplitudes. It is shown that the results of the proposed technique are more robust as compared to conventional classifiers. Statistical tests demonstrate that the proposed classifier is a promising method for discriminating between ADHD and BMD patients.

  18. Associations of Childhood and Adulthood Cognition with Bone Mineral Density in Later Adulthood: A Population-Based Longitudinal Study

    Directory of Open Access Journals (Sweden)

    Rebecca Bendayan

    2017-07-01

    Full Text Available This study explores the association between cognitive ability in childhood and midlife and bone health outcomes in early old age; and the relationships of these bone measures with contemporaneous and subsequent cognitive ability in the MRC National Survey of Health and Development (NSHD. This British birth cohort assessed areal and volumetric bone mineral density (aBMD and vBMD at age 60–64, derived from peripheral quantitative computed tomography and dual-energy X-ray absorptiometry, and cognitive performance from childhood to age 69, among 866 women and 792 men. Cognitive performance at age 15 was assessed using tests of verbal and non-verbal ability, and mathematics; and memory and search speed tasks were administered at ages 53, 60–64, and 69. Covariates included body size, pubertal timing, smoking, leisure time physical activity, socioeconomic circumstances and menopause timing. Multiple linear regression analyses showed that higher childhood cognitive ability was associated with higher hip aBMD, in women, and greater cortical and trabecular vBMD, in men. For women, there were positive associations between hip aBMD and total vBMD, and contemporaneous cognitive ability with associations also extending to subsequent cognitive ability for total vBMD. For men, some associations with trabecular and total vBMD emerged at ages 60–64 and 69 but only after adjusting for education, occupational class and health behaviors. Our findings highlight that higher cognitive ability in childhood is associated with BMD in early old age and these associations might be explained by social and behavioral pathways. The results suggest that individuals with greater cognitive ability in early life are more likely to engage in healthy behaviors (e.g., leisure time physical activity in adulthood, which in turn are associated with greater BMD later in life. Associations between bone health and cognitive performance should be considered within a life course

  19. Hip and fragility fracture prediction by 4-item clinical risk score and mobile heel BMD: a women cohort study

    Directory of Open Access Journals (Sweden)

    Thulesius Hans

    2010-03-01

    Full Text Available Abstract Background One in four Swedish women suffers a hip fracture yielding high morbidity and mortality. We wanted to revalidate a 4-item clinical risk score and evaluate a portable heel bone mineral density (BMD technique regarding hip and fragility fracture risk among elderly women. Methods In a population-based prospective cohort study we used clinical risk factors from a baseline questionnaire and heel BMD to predict a two-year hip and fragility fracture outcome for women, in a fracture preventive program. Calcaneal heel BMD was measured by portable dual X-ray laser absorptiometry (DXL and compared to hip BMD, measured with stationary dual X-ray absorptiometry (DXA technique. Results Seven women suffered hip fracture and 14 women fragility fracture/s (at hip, radius, humerus and pelvis among 285 women; 60% having heel BMD ≤ -2.5 SD. The 4-item FRAMO (Fracture and Mortality Index combined the clinical risk factors age ≥80 years, weight Conclusions In a follow-up study we identified high risk groups for hip and fragility fracture with our plain 4-item risk model. Increased fracture risk was also related to decreasing heel BMD in calcaneal bone, measured with a mobile DXL technique. A combination of high FRAMO Index, prior fragility fracture, and very low BMD restricted the high risk group to 11%, among whom most hip fractures occurred (71%. These practical screening methods could eventually reduce hip fracture incidence by concentrating preventive resources to high fracture risk women.

  20. Identification of a gene module associated with BMD through the integration of network analysis and genome-wide association data.

    Science.gov (United States)

    Farber, Charles R

    2010-11-01

    Bone mineral density (BMD) is influenced by a complex network of gene interactions; therefore, elucidating the relationships between genes and how those genes, in turn, influence BMD is critical for developing a comprehensive understanding of osteoporosis. To investigate the role of transcriptional networks in the regulation of BMD, we performed a weighted gene coexpression network analysis (WGCNA) using microarray expression data on monocytes from young individuals with low or high BMD. WGCNA groups genes into modules based on patterns of gene coexpression. and our analysis identified 11 gene modules. We observed that the overall expression of one module (referred to as module 9) was significantly higher in the low-BMD group (p = .03). Module 9 was highly enriched for genes belonging to the immune system-related gene ontology (GO) category "response to virus" (p = 7.6 × 10(-11)). Using publically available genome-wide association study data, we independently validated the importance of module 9 by demonstrating that highly connected module 9 hubs were more likely, relative to less highly connected genes, to be genetically associated with BMD. This study highlights the advantages of systems-level analyses to uncover coexpression modules associated with bone mass and suggests that particular monocyte expression patterns may mediate differences in BMD.

  1. Risk factors for low bone mass in healthy young adults from North India: studies on BMD and bone turnover markers

    Directory of Open Access Journals (Sweden)

    Anita Fotedar Verma

    2015-04-01

    Full Text Available Background: Despite availability of adequate sunshine, Indian population has the highest prevalence of low bone mass and Bone Mineral Content (BMC. Risk factors for osteoporosis have been extensively studied in the west but poorly investigated in India. We studied BMD and Bone Turnover Markers (BTMs among healthy young adults. Methods: Fifty one healthy young adults (28 Males, 23 Females in the age group of 20-35 years were studied. Morphometric, biochemical parameters and BMD (whole body, spine, hip and wrist were recorded. Anthropometric measurements included height, weight, BMI and Waist/Hip Ratio (WHR. BTMs studied included - serum Bone-Specific Alkaline Phosphatase (sBAP, serum Collagen cross-linked C-Terminal telopeptide (sCTx, serum Osteocalcin (OC and human intact parathyroid hormone (hPTH using standard ELISA kits. Results: Of 51 healthy volunteers 21.57% had normal BMD, 13.73% were frankly osteoporotic and 64.70% were osteopenic. Age, weight and BMI were the best predictors of total BMD and BMC at all sites. sCTX positively correlated with Total Bone Area (TBA, BMD at Hip and Forearm. Using multiple regressions - age, weight, and BMI were significant predictors of BMD in young adults. Percentage body fat had inverse correlation with BMC, BMD and TBA. Weight and height positively correlated with BMD at femoral neck, inter-trochanter and Ward's triangle. Body weight was best predictor of BMD at femoral neck, Ward's triangle, forearm UD, forearm MID and forearm1/3. Conclusion: Majority of healthy young Indians have poor bone health as evidenced by bone markers. [Int J Res Med Sci 2015; 3(4.000: 933-939

  2. Normal tempo of bone formation in Turner syndrome despite signs of accelerated bone resorption

    DEFF Research Database (Denmark)

    Cleemann, Line Hartvig; Holm, Kirsten Bagge; Kobbernagel, Hanne;

    2011-01-01

    Aims: To evaluate area bone mineral density (aBMD) and volumetric BMD (vBMD) by dual-energy X-ray absorptiometry, and relations to bone markers and hormones in adolescent women with Turner syndrome (TS). Methods: Cross-sectional study in TS patients (n = 37, 16.7 ± 3.4 years) and control group (n......' TS, compared to controls. vBMD(hip) was lower in 'ongoing GH' TS, but similar in 'previous GH'. z scores for aBMD were uniformly reduced in 'ongoing TS', but near-normalized in 'previous GH' TS. Bone formation and resorption markers were increased in 'ongoing GH' TS, while 'previous GH' TS had...

  3. Normal Tempo of Bone Formation in Turner Syndrome despite Signs of Accelerated Bone Resorption

    DEFF Research Database (Denmark)

    Cleemann, Line; Holm, Kirsten; Kobbernagel, Hanne;

    2011-01-01

    Aims: To evaluate area bone mineral density (aBMD) and volumetric BMD (vBMD) by dual-energy X-ray absorptiometry, and relations to bone markers and hormones in adolescent women with Turner syndrome (TS). Methods: Cross-sectional study in TS patients (n = 37, 16.7 ± 3.4 years) and control group (n......' TS, compared to controls. vBMD(hip) was lower in 'ongoing GH' TS, but similar in 'previous GH'. z scores for aBMD were uniformly reduced in 'ongoing TS', but near-normalized in 'previous GH' TS. Bone formation and resorption markers were increased in 'ongoing GH' TS, while 'previous GH' TS had...

  4. Comparison of high-resolution peripheral quantitative computerized tomography with dual-energy X-ray absorptiometry for measuring bone mineral density.

    Science.gov (United States)

    Colt, E; Akram, M; Pi Sunyer, F X

    2017-06-01

    The objective of this study was to compare the measurement of areal bone mineral density (aBMD) by dual-energy X-ray absorptiometry (DXA) with the measurement of volumetric bone mineral density (vBMD) by high-resolution peripheral computerized tomography (HR-pQCT) in subjects with a wide range of body mass indices (BMI). We scanned the arms and legs of 49 premenopausal women, aged 21-45 years, with BMI from 18.5 to 46.5, by HR-pQCT and found that there was a nonsignificant change in vBMD associated with increased BMI, whereas aBMD (DXA) was associated with a positive significant increase. HR-pQCT scans a slice at the extremity of the tibia and radius, whereas DXA scans the entire leg and arm. The correlation coefficients (r) of BMD (DXA) of the legs with BMI were 0.552, PD100) of legs and arms measured by HR-pQCT with BMI, W and %fat were not significant. Although HR-pQCT and DXA scan different parts of the bone, the high r of BMD with BMI and low r of bone density measured by HR-pQCT with BMI suggest that BMD measured by DXA is artifactually increased in the presence of obesity.

  5. Combining areal DXA bone mineral density and vertebrae postero-anterior width improves the prediction of vertebral strength

    Energy Technology Data Exchange (ETDEWEB)

    Taton, Grzegorz; Rokita, Eugeniusz [Jagiellonian University Medical College, Department of Biophysics, Krakow (Poland); Wrobel, Andrzej [Jagiellonian University, Institute of Physics, Krakow (Poland); Korkosz, Mariusz [Jagiellonian University Medical College, Department of Internal Medicine and Gerontology, Division of Rheumatology, Krakow (Poland)

    2013-12-15

    Areal bone mineral density (aBMD) measured by dual-energy X-ray absorptiometry (DXA) is an important determinant of bone strength (BS), despite the fact that the correlation between aBMD and BS is relatively weak. Parameters that describe BS more accurately are desired. The aim of this study was to determine whether the geometrical corrections applied to aBMD would improve its ability for BS prediction. We considered new parameters, estimated from a single DXA measurement, as well as BMAD (bone mineral apparent density) reported in the literature. In vitro studies were performed with the L3 vertebrae from 20 cadavers, which were studied with DXA and quantitative computed tomography (QCT). A mechanical strength assessment was carried out. Two new parameters were introduced: vBMD{sub min} = (aBMD)/(W{sub PA}{sup min}) and vBMD{sub av} = (aBMD)/(W{sub PA}{sup av}) (W{sub PA}{sup min} - minimal vertebral body width in postero-anterior (PA) view, W{sub PA}{sup av} - average PA vertebral body width). Volumetric BMD measured by QCT (vBMD), aBMD, BMAD, vBMD{sub min}, and vBMD{sub av} were correlated to ultimate load and ultimate stress (P{sub max}) to find the best predictor of vertebrae BS. The coefficients of correlation between P{sub max} and vBMD{sub min}, vBMD{sub av}, as well as BMAD, were r = 0.626 (p = 0.005), r = 0.610 (p = 0.006) and r = 0.567 (p = 0.012), respectively. Coefficients for vBMD and aBMD are r = 0.648 (p = 0.003) and r = 0.511 (p = 0.03), respectively. Our results showed that aBMD normalized by vertebrae dimensions describes vertebrae BS better than aBMD alone. The considered indices vBMD{sub av}, vBMD{sub min}, and BMAD can be measured in routine PA DXA and considerably improve BS variability prediction. vBMD{sub min} is superior compared to vBMD{sub av} and BMAD. (orig.)

  6. Changes in bone mineral density (BMD) around the cemented Exeter stem: a prospective study in 18 women with 5 years follow-up

    DEFF Research Database (Denmark)

    Damborg, Frank; Nissen, Nis; Jørgensen, Hans R I

    2008-01-01

    in all zones except 4 and 7. Despite this, the total periprosthetic BMD decreased during the follow-up relative to the immediate postoperative situation. There was no significant reduction in BMD in the contralateral hip. In the spine, we observed a significant rise in BMD. INTERPRETATION: 18 months...

  7. Low Normal TSH levels are Associated with Impaired BMD and Hip Geometry in the Elderly

    Science.gov (United States)

    Lee, Su Jin; Kim, Kyoung Min; Lee, Eun Young; Song, Mi Kyung; Kang, Dae Ryong; Kim, Hyeon Chang; Youm, Yoosik; Yun, Young Mi; Park, Hyun-Young; Kim, Chang Oh; Rhee, Yumie

    2016-01-01

    Subclinical hyperthyroidism is known to be associated with the risk of fractures in elderly people. However, there are few studies assessing whether low normal thyroid-stimulating hormone (TSH) levels affect bone density and geometry. Here, we aimed to assess the influence of the TSH level on bone mineral density (BMD) and geometry in elderly euthyroid subjects. This was a cross-sectional cohort study. A total of 343 men and 674 women with euthyroidism were included and analyzed separately. The subjects were divided into tertiles based on the serum TSH level. The BMD and geometry were measured using dual-energy X-ray absorptiometry and a hip structural analysis program. Multiple regression analysis was used to compute the odds ratios of osteoporosis in the lower TSH tertile group and the association between geometry parameters and the TSH level. We found that the femoral neck and total hip BMDs were lower in the lower TSH tertile group. In women, the cross-sectional area and cortical thickness of the femur were negatively associated with the TSH level in all three regions (the narrow neck, intertrochanter, and femoral shaft); however, in men, these geometry parameters were significantly associated with the TSH level only in the intertrochanter region. The buckling ratio, a bone geometry parameter representing cortical instability, was significantly higher in the lower TSH tertile group in all three regions in women, but not in men. Our results indicated that lower TSH levels in the euthyroid range are related to lower BMD and weaker femoral structure in elderly women. PMID:28053824

  8. Low Normal TSH levels are Associated with Impaired BMD and Hip Geometry in the Elderly.

    Science.gov (United States)

    Lee, Su Jin; Kim, Kyoung Min; Lee, Eun Young; Song, Mi Kyung; Kang, Dae Ryong; Kim, Hyeon Chang; Youm, Yoosik; Yun, Young Mi; Park, Hyun-Young; Kim, Chang Oh; Rhee, Yumie

    2016-12-01

    Subclinical hyperthyroidism is known to be associated with the risk of fractures in elderly people. However, there are few studies assessing whether low normal thyroid-stimulating hormone (TSH) levels affect bone density and geometry. Here, we aimed to assess the influence of the TSH level on bone mineral density (BMD) and geometry in elderly euthyroid subjects. This was a cross-sectional cohort study. A total of 343 men and 674 women with euthyroidism were included and analyzed separately. The subjects were divided into tertiles based on the serum TSH level. The BMD and geometry were measured using dual-energy X-ray absorptiometry and a hip structural analysis program. Multiple regression analysis was used to compute the odds ratios of osteoporosis in the lower TSH tertile group and the association between geometry parameters and the TSH level. We found that the femoral neck and total hip BMDs were lower in the lower TSH tertile group. In women, the cross-sectional area and cortical thickness of the femur were negatively associated with the TSH level in all three regions (the narrow neck, intertrochanter, and femoral shaft); however, in men, these geometry parameters were significantly associated with the TSH level only in the intertrochanter region. The buckling ratio, a bone geometry parameter representing cortical instability, was significantly higher in the lower TSH tertile group in all three regions in women, but not in men. Our results indicated that lower TSH levels in the euthyroid range are related to lower BMD and weaker femoral structure in elderly women.

  9. Higher prevalence of morphometric vertebral fractures in patients with recent coronary events independently of BMD measurements.

    Science.gov (United States)

    Silva, Henrique C; Pinheiro, Marcelo M; Genaro, Patrícia S; Castro, Charlles H M; Monteiro, Carlos M C; Fonseca, Francisco A H; Szejnfeld, Vera L

    2013-02-01

    Cardiovascular disease and osteoporosis are important causes of morbi-mortality in the elderly and may be mutually related. Low bone mineral density (BMD) may be associated with increased risk of cardiovascular events. We investigated the prevalence of low bone mass and fractures in metabolic syndrome patients with acute coronary events. A case-control study was conducted with 150 individuals (30-80years-old) with metabolic syndrome. Seventy-one patients had had an acute coronary syndrome episode in the last 6months (cases) and the remaining 79 had no coronary event (controls). Cases and controls were matched for gender, BMI and age. DXA measurements and body composition were performed while spine radiographs surveyed for vertebral fractures and vascular calcification. Biochemical bone and metabolic parameters were measured in all patients. No statistically significant difference in BMD and the prevalence of osteopenia, osteoporosis and non-vertebral fractures was observed between cases and controls. The prevalence of vertebral fractures and all fractures was higher in the cases (14.1 versus 1.3%, p=0.003 and 22.5versus7.6%, p=0.010, respectively). Male gender (OR=0.22 95% CI 0.58 to 0.83, p=0.026) and daily intake of more than 3 portions of dairy products (OR=0.19 95% CI 0.49 to 0.75, p=0.017) were associated with lower prevalence of fractures. Cases had higher risk for fractures (OR=4.97, 95% CI 1.17 to 30.30, p=0.031). Bone mass and body composition parameters were not associated with cardiovascular risk factors or bone mineral metabolism. Patients with fragility fractures had higher OPG serum levels than those without fractures (p<0.001). Our findings demonstrated that patients with recent coronary events have a higher prevalence of vertebral fractures independently of BMD.

  10. Combined Effects of Spaceflight and Age in Astronauts as Assessed by Areal Bone Mineral Density [BMD] and Trabecular Bone Score

    Science.gov (United States)

    Sibonga, Jean D.; Spector, Elizabeth R.; Ploutz-Snyder, R.; Evans, H. J.; King, L.; Watts, N. B.; Hans, D.; Smith, S. A.

    2013-01-01

    Spaceflight is a potential risk factor for secondary osteoporosis in astronauts. Although lumbar spine (LS) BMD declines rapidly, more than expected for age, there have been no fragility fractures in astronauts that can clearly be attributed to spaceflight. Recently, astronauts have been returning from 6-month spaceflights with absolute BMD still above young adult mean BMD. In spite of these BMD measurements, we project that the rapid loss in bone mass over long-duration spaceflight affects the bone microarchitecture of the LS which might predispose astronauts to premature vertebral fractures. Thus, we evaluated TBS, a novel texture index correlated with vertebral bone microarchitecture, as a means of monitoring changes to bone microarchitecture in astronauts as they age. We previously reported that TBS detects an effect of spaceflight (6-month duration), independent of BMD, in 51 astronauts (47+/-4 y) (Smith et al, J Clin Densitometry 2014). Hence, TBS was evaluated in serial DXA scans (Hologic Discovery W) conducted triennially in all active and retired astronauts and more frequently (before spaceflight, after spaceflight and until recovery) in the subset of astronauts flying 4-6- month missions. We used non-linear models to describe trends in observations (BMD or TBS) plotted as a function of astronaut age. We fitted 1175 observations of 311 astronauts, pre-flight and then postflight starting 3 years after landing or after astronaut's BMD for LS was restored to within 2% of preflight BMD. Observations were then grouped and defined as follows: 1) LD: after exposure to at least one long-duration spaceflight > 100 days and 2) SD: before LD and after exposure to at least one short-duration spaceflight lumbar spine to monitor the combined changes due to spaceflight and due to aging. This increased knowledge may enhance the ability to identify an intervention trigger for premature vertebral fractures in astronauts.

  11. Sex Specific Association of Physical Activity on Proximal Femur BMD in 9 to 10 Year-Old Children

    Science.gov (United States)

    Cardadeiro, Graça; Baptista, Fátima; Ornelas, Rui; Janz, Kathleen F.; Sardinha, Luís B.

    2012-01-01

    The results of physical activity (PA) intervention studies suggest that adaptation to mechanical loading at the femoral neck (FN) is weaker in girls than in boys. Less is known about gender differences associated with non-targeted PA levels at the FN or other clinically relevant regions of the proximal femur. Understanding sex-specific relationships between proximal femur sensitivity and mechanical loading during non-targeted PA is critical to planning appropriate public health interventions. We examined sex-specific associations between non-target PA and bone mineral density (BMD) of three sub-regions of the proximal femur in pre- and early-pubertal boys and girls. BMD at the FN, trochanter (TR) and intertrochanter (IT) regions, and lean mass of the whole body were assessed using dual-energy x-ray absorptiometry in 161 girls (age: 9.7±0.3 yrs) and 164 boys (age: 9.7±0.3 yrs). PA was measured using accelerometry. Multiple linear regression analyses (adjusted for body height, total lean mass and pubertal status) revealed that vigorous PA explained 3–5% of the variability in BMD at all three sub-regions in boys. In girls, vigorous PA explained 4% of the variability in IT BMD and 6% in TR BMD. PA did not contribute to the variance in FN BMD in girls. An additional 10 minutes per day of vigorous PA would be expected to result in a ∼1% higher FN, TR, and IT BMD in boys (p<0.05) and a ∼2% higher IT and TR BMD in girls. In conclusion, vigorous PA can be expected to contribute positively to bone health outcomes for boys and girls. However, the association of vigorous PA to sub-regions of the proximal femur varies by sex, such that girlś associations are heterogeneous and the lowest at the FN, but stronger at the TR and the IT, when compared to boys. PMID:23209801

  12. A reduced volumetric expansion factor plot

    Science.gov (United States)

    Hendricks, R. C.

    1979-01-01

    A reduced volumetric expansion factor plot has been constructed for simple fluids which is suitable for engineering computations in heat transfer. Volumetric expansion factors have been found useful in correlating heat transfer data over a wide range of operating conditions including liquids, gases and the near critical region.

  13. PTHR1 polymorphisms influence BMD variation through effects on the growing skeleton

    DEFF Research Database (Denmark)

    Vilariño-Güell, Carles; Miles, Lisa J; Duncan, Emma L

    2007-01-01

    -intron boundaries, and 1,500 bp of its promoter region, was screened for polymorphisms by denaturing high-performance liquid chromatography (dHPLC) and sequencing in 36 osteoporotic cases. Eleven single-nucleotide polymorphisms (SNPs), one tetranucleotide repeat, and one tetranucleotide deletion were identified....... A cohort of 634 families, including 1,236 men (39%) and 1,926 women (61%) ascertained with probands with low BMD (ZParents and Children (ALSPAC) cohort (785 unrelated individuals, mean age 118 months), were genotyped for the five...

  14. EE.UU. y el debate del sistema de defensa estratégica BMD

    Directory of Open Access Journals (Sweden)

    David García

    2008-05-01

    Full Text Available Este artículo analiza el desarrollo por parte de EE.UU. de un sistema de defensa estratégica contra misiles balísticos (BMD, en el contexto de la crítica al concepto de disuasión nuclear tras la Guerra Fría y de la política de seguridad y defensa de la Administración Bush. En las conclusiones, se relacionan estas capacidades con la política espacial estadounidense y la creación de sistemas de defensa basados en el espacio.

  15. A RESEARCH ON THE EFFECTS OF TEA, SMOKING AND SODA ON WEIGHT HEIGHT AND BONE MINARAL DENSITY (BMD OF ATHLETS

    Directory of Open Access Journals (Sweden)

    H. Bayram TEMUR

    2011-12-01

    Full Text Available In this study, it was aimed to investigate whether incomes of the family, tea, smoke and soda have effect on the weight, height and bone mineral density of athletes. 80 athletes whose average age was 16.62- 0.92 were included. BMD of the lumbar spine (L1-L4 of the subjects was measured by Dual energy X-ray Absorbtiometry (DEXA (g/cm. Values of the family income and the daily consumption of tea, smoke and soda in the families of the athletes were researched. Values of weight and height of the athletes were also determined. In the analyses of the data obtained in the study, SPSS 15.0 package program was used. The results of this study demonstrated that there is no relation between the values of smoke, tea and soda with the values of weight, height and BMD. However, despite the lack of a relationship between the BMD values and the family income level, significant correlation was obtained between the BMD values with the height values (p≤0.01 and the weight values (p≤0.05. Consequently it was determined that tea, smoke and soda do not have effects on weight, height and BMD. Hence, it is thought that the lack of effect of smoking on weight, height and BMD could be due to the less daily smoking (1.67-0.79 and less smoking average in the subjects (26.3%.

  16. Bioprocess-centered molecular design (BMD) for the efficient production of an interfacially active peptide.

    Science.gov (United States)

    Morreale, Giacomo; Lee, Eun Gyo; Jones, Daniel B; Middelberg, Anton P J

    2004-09-30

    The efficient expression and purification of an interfacially active peptide (mLac21) was achieved by using bioprocess-centered molecular design (BMD), wherein key bioprocess considerations are addressed during the initial molecular biology work. The 21 amino acid mLac21 peptide sequence is derived from the lac repressor protein and is shown to have high affinity for the oil-water interface, causing a substantial reduction in interfacial tension following adsorption. The DNA coding for the peptide sequence was cloned into a modified pET-31(b) vector to permit the expression of mLac21 as a fusion to ketosteroid isomerase (KSI). Rational iterative molecular design, taking into account the need for a scaleable bioprocess flowsheet, led to a simple and efficient bioprocess yielding mLac21 at 86% purity following ion exchange chromatography (and >98% following chromatographic polishing). This case study demonstrates that it is possible to produce acceptably pure peptide for potential commodity applications using common scaleable bioprocess unit operations. Moreover, it is shown that BMD is a powerful strategy that can be deployed to reduce bioseparation complexity.

  17. Presenting a Spatial-Geometric EEG Feature to Classify BMD and Schizophrenic Patients

    Directory of Open Access Journals (Sweden)

    Fatemeh AliMardani

    2016-03-01

    Full Text Available Schizophrenia (SZ and bipolar mood disorder (BMD patients demonstrate some similar signs and symptoms; therefore, distinguishing those using qualitative criteria is not an easy task especially when these patients experience manic or hallucination phases. This study is aimed at classifying these patients by spatial analysis of their electroencephalogram (EEG signals. In this way, 22-channels EEG signals were recorded from 52 patients (26 patients with SZ and 26 patients with BMD. No stimulus has been used during the signal recording in order to investigate whether background EEGs of these patients in the idle state contain discriminative information or not. The EEG signals of all channels were segmented into stationary intervals called “frame” and the covariance matrix of each frame is separately represented in manifold space. Exploiting Riemannian metrics in the manifold space, the classification of sample covariance matrices is carried out by a simple nearest neighbor classifier. To evaluate our method, leave one patient out cross validation approach has been used. The achieved results imply that the difference in the spatial information between the patients along with control subjects is meaningful. Nevertheless, to enhance the diagnosis rate, a new algorithm is introduced in the manifold space to select those frames which are less deviated around the mean as the most probable noise free frames. The classification accuracy is highly improved up to 98.95% compared to the conventional methods. The achieved result is promising and the computational complexity is also suitable for real time processing.

  18. Bone loss during partial weight bearing (1/6th gravity) is mitigated by resistance and aerobic exercise in mice

    Science.gov (United States)

    Boudreaux, R. D.; Metzger, C. E.; Macias, B. R.; Shirazi-Fard, Y.; Hogan, H. A.; Bloomfield, S. A.

    2014-06-01

    Astronauts on long duration missions continue to experience bone loss, as much as 1-2% each month, for up to 4.5 years after a mission. Mechanical loading of bone with exercise has been shown to increase bone formation, mass, and geometry. The aim of this study was to compare the efficacy of two exercise protocols during a period of reduced gravitational loading (1/6th body weight) in mice. Since muscle contractions via resistance exercise impart the largest physiological loads on the skeleton, we hypothesized that resistance training (via vertical tower climbing) would better protect against the deleterious musculoskeletal effects of reduced gravitational weight bearing when compared to endurance exercise (treadmill running). Young adult female BALB/cBYJ mice were randomly assigned to three groups: 1/6 g (G/6; n=6), 1/6 g with treadmill running (G/6+RUN; n=8), or 1/6 g with vertical tower climbing (G/6+CLB; n=9). Exercise was performed five times per week. Reduced weight bearing for 21 days was achieved through a novel harness suspension system. Treadmill velocity (12-20 m/min) and daily run time duration (32-51 min) increased incrementally throughout the study. Bone geometry and volumetric bone mineral density (vBMD) at proximal metaphysis and mid-diaphysis tibia were assessed by in vivo peripheral quantitative computed tomography (pQCT) on days 0 and 21 and standard dynamic histomorphometry was performed on undemineralized sections of the mid-diaphysis after tissue harvest. G/6 caused a significant decrease (P<0.001) in proximal tibia metaphysis total vBMD (-9.6%). These reductions of tibia metaphyseal vBMD in G/6 mice were mitigated in both G/6+RUN and G/6+CLB groups (P<0.05). After 21 days of G/6, we saw an absolute increase in tibia mid-diaphysis vBMD and in distal metaphysis femur vBMD in both G/6+RUN and G/6+CLB mice (P<0.05). Substantial increases in endocortical and periosteal mineralizing surface (MS/BS) at mid-diaphysis tibia in G/6+CLB demonstrate that

  19. Surfactant enhanced volumetric sweep efficiency

    Energy Technology Data Exchange (ETDEWEB)

    Harwell, J.H.; Scamehorn, J.F.

    1989-10-01

    Surfactant-enhanced waterflooding is a novel EOR method aimed to improve the volumetric sweep efficiencies in reservoirs. The technique depends upon the ability to induce phase changes in surfactant solutions by mixing with surfactants of opposite charge or with salts of appropriate type. One surfactant or salt solution is injected into the reservoir. It is followed later by injection of another surfactant or salt solution. The sequence of injections is arranged so that the two solutions do not mix until they are into the permeable regions well away from the well bore. When they mix at this point, by design they form a precipitate or gel-like coacervate phase, plugging this permeable region, forcing flow through less permeable regions of the reservoir, improving sweep efficiency. The selectivity of the plugging process is demonstrated by achieving permeability reductions in the high permeable regions of Berea sandstone cores. Strategies were set to obtain a better control over the plug placement and the stability of plugs. A numerical simulator has been developed to investigate the potential increases in oil production of model systems. Furthermore, the hardness tolerance of anionic surfactant solutions is shown to be enhanced by addition of monovalent electrolyte or nonionic surfactants. 34 refs., 32 figs., 8 tabs.

  20. Ethnic differences in bone geometry between White, Black and South Asian men in the UK.

    Science.gov (United States)

    Zengin, A; Pye, S R; Cook, M J; Adams, J E; Wu, F C W; O'Neill, T W; Ward, K A

    2016-10-01

    Relatively little is known about the bone health of ethnic groups within the UK and data are largely restricted to women. The aim of this study was to investigate ethnic differences in areal bone mineral density (aBMD), volumetric bone mineral density (vBMD), bone geometry and strength in UK men. White European, Black Afro-Caribbean and South Asian men aged over 40years were recruited from Greater Manchester, UK. aBMD at the spine, hip, femoral neck and whole body were measured by DXA. Bone geometry, strength and vBMD were measured at the radius and tibia using pQCT at the metaphysis (4%) and diaphysis (50% radius; 38% tibia) sites. Adjustments were made for age, weight and height. Black men had higher aBMD at the whole body, total hip and femoral neck compared to White and South Asian men independent of body size adjustments, with no differences between the latter two groups. White men had longer hip axis lengths than both Black and South Asian men. There were fewer differences in vBMD but White men had significantly lower cortical vBMD at the tibial diaphysis than Black and South Asian men (pradius diaphysis, Black men had larger bones with thicker cortices and greater bending strength than the other groups. There were fewer differences between White and South Asian men. At the metaphysis, South Asian men had smaller bones (p=0.02) and lower trabecular vBMD at the tibia (p=0.003). At the diaphysis, after size-correction, South Asian men had similar sized bones but thinner cortices than White men; measures of strength were not broadly reduced in the South Asian men. Combining pQCT and DXA measurements has given insight into differences in bone phenotype in men from different ethnic backgrounds. Understanding such differences is important in understanding the aetiology of male osteoporosis. Copyright © 2016 The Authors. Published by Elsevier Inc. All rights reserved.

  1. Screening for Osteoporosis in Older Men: Operating Characteristics of Proposed Strategies for Selecting Men for BMD Testing.

    Science.gov (United States)

    Diem, Susan J; Peters, Katherine W; Gourlay, Margaret L; Schousboe, John T; Taylor, Brent C; Orwoll, Eric S; Cauley, Jane A; Langsetmo, Lisa; Crandall, Carolyn J; Ensrud, Kristine E

    2017-08-16

    The optimal approach for selecting men for bone mineral density (BMD) testing to screen for osteoporosis is uncertain. To compare strategies for selecting older men for screening BMD testing. Prospective cohort study. A total of 4043 community-dwelling men aged ≥70 years at four US sites. BMD at the total hip, femoral neck, and lumbar spine using dual-energy x-ray absorptiometry (DXA). Sensitivity, specificity, positive predictive value, negative predictive value, positive likelihood ratio, negative likelihood ratio, and area under the receiver operating curve (AUC) of the Osteoporosis Self-Assessment Tool (OST) and Fracture Risk Assessment Tool (FRAX) without BMD to discriminate between those with and without osteoporosis as defined by World Health Organization (WHO) diagnostic criteria, and between those recommended and not recommended for pharmacologic therapy based on the National Osteoporosis Foundation (NOF) guidelines. Among the cohort, 216 (5.3%) had a BMD T-score ≤ -2.5 at the femoral neck, total hip, or lumbar spine, and 1184 (29.2%) met criteria for consideration of pharmacologic therapy according to NOF guidelines. The OST had better discrimination (AUC 0.68) than the FRAX (AUC 0.62; p = 0.004) for identifying T-score-defined osteoporosis. Use of an OST threshold of <2 resulted in sensitivity of 0.83 and specificity of 0.36 for the identification of osteoporosis, compared to sensitivity of 0.59 and specificity of 0.59 for the use of FRAX with a cutoff of 9.3% 10-year risk of major osteoporotic fracture. The OST performs modestly better than the more complex FRAX in selecting older men for BMD testing to screen for osteoporosis; the use of either tool substantially reduces the proportion of men referred for BMD testing compared to universal screening. Of 1000 men aged 70 and older in this community-based cohort, the use of an OST cutoff of <2 to select men for BMD testing would result in 654 men referred for BMD testing, of whom 44 would be

  2. Serum BAP as the clinically useful marker for predicting BMD reduction in diabetic hemodialysis patients with low PTH.

    Science.gov (United States)

    Ueda, Misako; Inaba, Masaaki; Okuno, Senji; Maeno, Yoshifumi; Ishimura, Eiji; Yamakawa, Tomoyuki; Nishizawa, Yoshiki

    2005-07-22

    With decrease of serum PTH in hemodialysis (HD) patients, other factors besides parathyroid hormone (PTH) become important in regulating bone metabolism. We investigated which serum bone metabolic marker is the best to predict the bone mineral density (BMD) reduction in HD patients with serum PTHBAP), intact osteocalcin (OC), and N-terminal propeptide of type I collagen (PINP), and the bone resorption markers, deoxypyridinoline (DPD), pyridinoline (PYD), and beta-crossLaps (beta-CTx) were measured in serum from 137 HD patients. BMD of all patients was measured twice, approximately 1.5 years before and 1.5 years after measurement of their markers of bone metabolism. In all 137 HD patients, serum BAP was the only marker significantly higher in those with BMD reduction than in those without. In 42 diabetes mellitus (DM) HD patients with serum PTHBAP was again the only marker to discriminate those with BMD reduction from those without. At serum PTHBAP retained tendency toward higher value. These findings suggest that serum BAP might be the most sensitive to identify small changes of bone metabolism in low bone turnover state. Retrospective study confirmed the usefulness of serum BAP in clinical practice by significantly higher values in those with bone loss at PTHBAP is a clinically useful bone formation marker to predict the BMD reduction in DM HD patients with low level of PTH.

  3. Distribution of bone density in the proximal femur and its association with hip fracture risk in older men: the osteoporotic fractures in men (MrOS) study.

    Science.gov (United States)

    Yang, Lang; Burton, Annabel C; Bradburn, Mike; Nielson, Carrie M; Orwoll, Eric S; Eastell, Richard

    2012-11-01

    This prospective case-cohort study aimed to map the distribution of bone density in the proximal femur and examine its association with hip fracture. We analyzed baseline quantitative computed tomography (QCT) scans in 250 men aged 65 years or older, which comprised a randomly-selected subcohort of 210 men and 40 cases of first hip fracture during a mean follow-up period of 5.5 years. We quantified cortical, trabecular, and integral volumetric bone mineral density (vBMD), and cortical thickness (CtTh) in four quadrants of cross-sections along the length of the femoral neck (FN), intertrochanter (IT), and trochanter (TR). In most quadrants, vBMDs and CtTh were significantly (p hip fracture, we merged the two quadrants in the medial and lateral aspects of the FN, IT, and TR. At most sites, QCT measurements were associated significantly (p hip fracture, the hazard ratio (HR) adjusted for age, body mass index (BMI), and clinical site for a 1-SD decrease ranged between 2.28 (95% confidence interval [CI], 1.44-3.63) to 6.91 (95% CI, 3.11-15.53). After additional adjustment for total hip (TH) areal BMD (aBMD), trabecular vBMDs at the FN, TR, and TH were still associated with hip fracture significantly (p fracture significantly (p > 0.05) better than TH aBMD. With an area under the receiver operating characteristic curve (AUC) of 0.901 (95% CI, 0.852-0.950), the regression model combining TH aBMD, age, and trabecular vBMD predicted hip fracture significantly (p hip fracture risk and highlight trabecular vBMD at the FN and TR as an independent risk factor. Copyright © 2012 American Society for Bone and Mineral Research.

  4. Laser Based 3D Volumetric Display System

    Science.gov (United States)

    1993-03-01

    Literature, Costa Mesa, CA July 1983. 3. "A Real Time Autostereoscopic Multiplanar 3D Display System", Rodney Don Williams, Felix Garcia, Jr., Texas...8217 .- NUMBERS LASER BASED 3D VOLUMETRIC DISPLAY SYSTEM PR: CD13 0. AUTHOR(S) PE: N/AWIU: DN303151 P. Soltan, J. Trias, W. Robinson, W. Dahlke 7...laser generated 3D volumetric images on a rotating double helix, (where the 3D displays are computer controlled for group viewing with the naked eye

  5. Predicting fractures in an international cohort using risk factor algorithms without BMD.

    Science.gov (United States)

    Sambrook, Philip N; Flahive, Julie; Hooven, Fred H; Boonen, Steven; Chapurlat, Roland; Lindsay, Robert; Nguyen, Tuan V; Díez-Perez, Adolfo; Pfeilschifter, Johannes; Greenspan, Susan L; Hosmer, David; Netelenbos, J Coen; Adachi, Jonathan D; Watts, Nelson B; Cooper, Cyrus; Roux, Christian; Rossini, Maurizio; Siris, Ethel S; Silverman, Stuart; Saag, Kenneth G; Compston, Juliet E; LaCroix, Andrea; Gehlbach, Stephen

    2011-11-01

    Clinical risk factors are associated with increased probability of fracture in postmenopausal women. We sought to compare prediction models using self-reported clinical risk factors, excluding BMD, to predict incident fracture among postmenopausal women. The GLOW study enrolled women aged 55 years or older from 723 primary-care practices in 10 countries. The population comprised 19,586 women aged 60 years or older who were not receiving antiosteoporosis medication and were followed annually for 2 years. Self-administered questionnaires were used to collect data on characteristics, fracture risk factors, previous fractures, and health status. The main outcome measure compares the C index for models using the WHO Fracture Risk (FRAX), the Garvan Fracture Risk Calculator (FRC), and a simple model using age and prior fracture. Over 2 years, 880 women reported incident fractures including 69 hip fractures, 468 "major fractures" (as defined by FRAX), and 583 "osteoporotic fractures" (as defined by FRC). Using baseline clinical risk factors, both FRAX and FRC showed a moderate ability to correctly order hip fracture times (C index for hip fracture 0.78 and 0.76, respectively). C indices for "major" and "osteoporotic" fractures showed lower values, at 0.61 and 0.64. Neither algorithm was better than the model based on age + fracture history alone (C index for hip fracture 0.78). In conclusion, estimation of fracture risk in an international primary-care population of postmenopausal women can be made using clinical risk factors alone without BMD. However, more sophisticated models incorporating multiple clinical risk factors including falls were not superior to more parsimonious models in predicting future fracture in this population.

  6. The ESR1 (6q25 locus is associated with calcaneal ultrasound parameters and radial volumetric bone mineral density in European men.

    Directory of Open Access Journals (Sweden)

    Kate L Holliday

    Full Text Available PURPOSE: Genome-wide association studies (GWAS have identified 6q25, which incorporates the oestrogen receptor α gene (ESR1, as a quantitative trait locus for areal bone mineral density (BMD(a of the hip and lumbar spine. The aim of this study was to determine the influence of this locus on other bone health outcomes; calcaneal ultrasound (QUS parameters, radial peripheral quantitative computed tomography (pQCT parameters and markers of bone turnover in a population sample of European men. METHODS: Eight single nucleotide polymorphisms (SNP in the 6q25 locus were genotyped in men aged 40-79 years from 7 European countries, participating in the European Male Ageing Study (EMAS. The associations between SNPs and measured bone parameters were tested under an additive genetic model adjusting for centre using linear regression. RESULTS: 2468 men, mean (SD aged 59.9 (11.1 years had QUS measurements performed and bone turnover marker levels measured. A subset of 628 men had DXA and pQCT measurements. Multiple independent SNPs showed significant associations with BMD using all three measurement techniques. Most notably, rs1999805 was associated with a 0.10 SD (95%CI 0.05, 0.16; p = 0.0001 lower estimated BMD at the calcaneus, a 0.14 SD (95%CI 0.05, 0.24; p = 0.004 lower total hip BMD(a, a 0.12 SD (95%CI 0.02, 0.23; p = 0.026 lower lumbar spine BMD(a and a 0.18 SD (95%CI 0.06, 0.29; p = 0.003 lower trabecular BMD at the distal radius for each copy of the minor allele. There was no association with serum levels of bone turnover markers and a single SNP which was associated with cortical density was also associated with cortical BMC and thickness. CONCLUSIONS: Our data replicate previous associations found between SNPs in the 6q25 locus and BMD(a at the hip and extend these data to include associations with calcaneal ultrasound parameters and radial volumetric BMD.

  7. Effect of ovariectomy on BMD, micro-architecture and biomechanics of cortical and cancellous bones in a sheep model.

    Science.gov (United States)

    Wu, Zi-xiang; Lei, Wei; Hu, Yun-yu; Wang, Hai-qiang; Wan, Shi-yong; Ma, Zhen-sheng; Sang, Hong-xun; Fu, Suo-chao; Han, Yi-sheng

    2008-11-01

    Osteoporotic/osteopenia fractures occur most frequently in trabeculae-rich skeletal sites. The purpose of this study was to use a high-resolution micro-computed tomography (micro-CT) and dual energy X-ray absorptionmeter (DEXA) to investigate the changes in micro-architecture and bone mineral density (BMD) in a sheep model resulted from ovariectomy (OVX). Biomechanical tests were performed to evaluate the strength of the trabecular bone. Twenty adult sheeps were randomly divided into three groups: sham group (n=8), group 1 (n=4) and group 2 (n=8). In groups 1 and 2, all sheep were ovariectomized (OVX); in the sham group, the ovaries were located and the oviducts were ligated. In all animals, BMD for lumbar spine was obtained during the surgical procedure. BMD at the spine, femoral neck and femoral condyle was determined 6 months (group 1) and 12 months (group 2) post-OVX. Lumbar spines and femora were obtained and underwent BMD scan, micro-CT analysis. Compressive mechanical properties were determined from biopsies of vertebral bodies and femoral condyles. BMD, micro-architectural parameters and mechanical properties of cancellous bone did not decrease significantly at 6 months post-OVX. Twelve months after OVX, BMD, micro-architectural parameters and mechanical properties decreased significantly. The results of linear regression analyses showed that trabecular thickness (Tb.Th) (r=0.945, R2=0.886) and bone volume fraction (BV/TV) (r=0.783, R2=0.586) had strong (R2>0.5) correlation to compression stress. In OVX sheep, changes in the structural parameters of trabecular bone are comparable to the human situation during osteoporosis was induced. The sheep model presented seems to meet the criteria for an osteopenia model for fracture treatment with respect to morphometric and mechanical properties. But the duration of OVX must be longer than 12 months to ensure the animal model can be established successfully.

  8. Increasing the Number of Unloading/Reambulation Cycles does not Adversely Impact Body Composition and Lumbar Bone Mineral Density but Reduces Tissue Sensitivity

    Science.gov (United States)

    Gupta, Shikha; Manske, Sarah L; Judex, Stefan

    2012-01-01

    A single exposure to hindlimb unloading leads to changes in body mass, body composition and bone, but the consequences of multiple exposures are not yet understood. Within a 18wk period, adult C57BL/6 male mice were exposed to one (1x-HLU), two (2x-HLU) or three (3x-HLU) cycles of 2 wk of hindlimb unloading (HLU) followed by 4 wk of reambulation (RA), or served as ambulatory age-matched controls. In vivo µCT longitudinally tracked changes in abdominal adipose and lean tissues, lumbar vertebral apparent volumetric bone mineral density (vBMD) and upper hindlimb muscle cross-sectional area before and after the final HLU and RA cycle. Significant decreases in total adipose tissue and vertebral vBMD were observed such that all unloaded animals reached similar values after the final unloading cycle. However, the magnitude of these losses diminished in mice undergoing their 2nd or 3rd HLU cycle. Irrespective of the number of HLU/RA cycles, total adipose tissue and vertebral vBMD recovered and were no different from age-matched controls after the final RA period. In contrast, upper hindlimb muscle cross-sectional area was significantly lower than controls in all unloaded groups after the final RA period. These results suggest that tissues in the abdominal region are more resilient to multiple bouts of unloading and more amenable to recovery during reambulation than the peripheral musculoskeletal system. PMID:23976804

  9. Coronary arterial calcification and thoracic spine mineral density in early menopause.

    Science.gov (United States)

    Miyabara, Y; Camp, J; Holmes, D; Lahr, B; Bailey, K; Miller, V M; Kearns, A E

    2011-08-01

    Cardiovascular disease and osteoporosis increase in women after menopause. While aortic calcification is associated with bone loss in women, a similar relationship for coronary arterial calcification (CAC), a risk factor for coronary artery disease in women, is less clear. This study was designed to examine the relationship between CAC and volumetric bone mineral density (vBMD) in women (n=137) who were within a median of 18 months past their last menses at screening for the Kronos Early Estrogen Prevention Study (KEEPS). CAC was measured using 64-slice computed tomography; vBMD was measured from these images using the Spine Cancer Assessment program. Concentrations of osteocalcin, bone alkaline phosphatase, tartrate-resident acid phosphatase-5b and osteopontin as bone matrix protein in serum and plasma were evaluated by ELISA. CAC scores ranged from 0 to 327.6 Agatston Units (AU); 113 women had a score of 0 AU, 20 had a CAC score between 0 and 50 AU, and four had a CAC score>50 AU. Although not statistically significant, there was a trend toward decreasing central density of thoracic T9 with increasing CAC. On average, levels of markers of bone turnover were within the normal range but did not correlate with age or with months past menopause. Clinically significant CAC and spine vBMD are quantifiable from the same scans within the first 3 years of menopause. Additional work is needed to determine how these measurements change with increasing age or with estrogenic treatments.

  10. Sex specific association of physical activity on proximal femur BMD in 9 to 10 year-old children.

    Directory of Open Access Journals (Sweden)

    Graça Cardadeiro

    Full Text Available The results of physical activity (PA intervention studies suggest that adaptation to mechanical loading at the femoral neck (FN is weaker in girls than in boys. Less is known about gender differences associated with non-targeted PA levels at the FN or other clinically relevant regions of the proximal femur. Understanding sex-specific relationships between proximal femur sensitivity and mechanical loading during non-targeted PA is critical to planning appropriate public health interventions. We examined sex-specific associations between non-target PA and bone mineral density (BMD of three sub-regions of the proximal femur in pre- and early-pubertal boys and girls. BMD at the FN, trochanter (TR and intertrochanter (IT regions, and lean mass of the whole body were assessed using dual-energy x-ray absorptiometry in 161 girls (age: 9.7±0.3 yrs and 164 boys (age: 9.7±0.3 yrs. PA was measured using accelerometry. Multiple linear regression analyses (adjusted for body height, total lean mass and pubertal status revealed that vigorous PA explained 3-5% of the variability in BMD at all three sub-regions in boys. In girls, vigorous PA explained 4% of the variability in IT BMD and 6% in TR BMD. PA did not contribute to the variance in FN BMD in girls. An additional 10 minutes per day of vigorous PA would be expected to result in a ∼1% higher FN, TR, and IT BMD in boys (p<0.05 and a ∼2% higher IT and TR BMD in girls. In conclusion, vigorous PA can be expected to contribute positively to bone health outcomes for boys and girls. However, the association of vigorous PA to sub-regions of the proximal femur varies by sex, such that girlś associations are heterogeneous and the lowest at the FN, but stronger at the TR and the IT, when compared to boys.

  11. Genetic association study of WNT10B polymorphisms with BMD and adiposity parameters in Danish and Belgian males

    DEFF Research Database (Denmark)

    Van Camp, Jasmijn K; Beckers, Sigri; Zegers, Doreen;

    2013-01-01

    Because of the importance of the Wnt pathway in the development and maintenance of both adipose and bone tissue, we wanted to evaluate the involvement of WNT10B, a Wnt pathway activator, in adipogenesis and osteoblastogenesis in humans. Genetic association between WNT10B polymorphisms and adiposity...... a previously shown negative effect on BMD. No significant associations were observed in the SIBLOS population. In the present study, no association between WNT10B polymorphisms and adiposity parameters was found. However, our results clearly illustrate a role for WNT10B variants in determining human BMD...

  12. Would Interstitial Fluid Flow be Responsible for Skeletal Maintenance in Tail-Suspended Rats?

    Science.gov (United States)

    Li, Wen-Ting; Huang, Yun-Fei; Sun, Lian-Wen; Luan, Hui-Qin; Zhu, Bao-Zhang; Fan, Yu-Bo

    2016-12-01

    Despite the fast development of manned space flight, the mechanism and countermeasures of weightlessness osteoporosis in astronauts are still within research. It is accepted that unloading has been considered as primary factor, but the precise mechanism is still unclear. Since bone's interstitial fluid flow (IFF) is believed to be significant to nutrient supply and waste metabolism of bone tissue, it may influence bone quality as well. We investigated IFF's variation in different parts of body (included parietal bone, ulna, lumbar, tibia and tailbone) of rats using a tail-suspended (TS) system. Ten female Sprague-Dawley (SD) rats were divided into two groups: control (CON) and tail-suspension (TS) group. And after 21 days' experiment, the rats were injected reactive red to observe lacuna's condition under a confocal laser scanning microscope. The variations of IFF were analyzed by the number and area of lacuna. Volumetric bone mineral density (vBMD) and microarchitecture of bones were evaluated by micro-CT. The correlation coefficients between lacuna's number/area and vBMD were also analyzed. According to our experimental results, a 21 days' tail-suspension could cause a decrease of IFF in lumbar, tibia and tailbone and an increase of IFF in ulna. But in parietal bone, it showed no significant change. The vBMD and microarchitecture parameters also decreased in lumbar and tibia and increased in ulna. But in parietal bone and tailbone, it showed no significant change. And correlation analysis showed significant correlation between vBMD and lacuna's number in lumbar, tibia and ulna. Therefore, IFF decrease may be partly contribute to bone loss in tail-suspended rats, and it should be further investigated.

  13. Effects of total gastrectomy on plasma silicon and amino acid concentrations in men.

    Science.gov (United States)

    Tatara, Marcin R; Krupski, Witold; Szpetnar, Maria; Dąbrowski, Andrzej; Bury, Paweł; Szabelska, Anna; Charuta, Anna; Boguszewska-Czubara, Anna; Maciejewski, Ryszard; Wallner, Grzegorz

    2015-12-01

    The aim of the study was to determine one-year effects of total gastrectomy on plasma silicon and free amino acid concentrations in patients and evaluate changes of volumetric bone mineral density (vBMD) in lumbar spine. Eight patients were enrolled to the control (CTR) group. Six patients subjected to total gastrectomy (GX group) were included to the experimental group. vBMD in trabecular and cortical bone was measured in lumbar vertebrae at baseline (before surgery) and one year later using quantitative computed tomography. Plasma concentrations of silicon and free amino acids were determined at baseline and one year later using photometric method and ion-exchange chromatography. Body weights within CTR and GX groups were not different after one-year follow-up when compared to the baseline values (P > 0.05). An average annual decrease of vBMD in the trabecular bone in the gastrectomized patients reached 15.0% in lumbar spine and was significantly different in comparison to the percentage changes observed in CTR group (P = 0.02). One-year percentage change of vBMD in the cortical bone in L1 and L2 has shown significantly decreased values by 10.5 and 9.1% in the GX group when compared to the percentage change observed in the controls (P silicon was significantly lowered by 26.7% one year after the total gastrectomy when compared to the baseline value (P = 0.009). Total gastrectomy in patients has induced severe osteoporotic changes in lumbar spine within one-year period. The observed osteoporotic changes were associated with decreased plasma concentration of silicon indicating importance of exocrine and endocrine functions of stomach for silicon homeostasis maintenance. Gastrectomy-induced bone loss was not related to decreased amino acid concentration in plasma obtained from overnight fasted patients.

  14. Would Interstitial Fluid Flow be Responsible for Skeletal Maintenance in Tail-Suspended Rats?

    Science.gov (United States)

    Li, Wen-Ting; Huang, Yun-Fei; Sun, Lian-Wen; Luan, Hui-Qin; Zhu, Bao-Zhang; Fan, Yu-Bo

    2017-02-01

    Despite the fast development of manned space flight, the mechanism and countermeasures of weightlessness osteoporosis in astronauts are still within research. It is accepted that unloading has been considered as primary factor, but the precise mechanism is still unclear. Since bone's interstitial fluid flow (IFF) is believed to be significant to nutrient supply and waste metabolism of bone tissue, it may influence bone quality as well. We investigated IFF's variation in different parts of body (included parietal bone, ulna, lumbar, tibia and tailbone) of rats using a tail-suspended (TS) system. Ten female Sprague-Dawley (SD) rats were divided into two groups: control (CON) and tail-suspension (TS) group. And after 21 days' experiment, the rats were injected reactive red to observe lacuna's condition under a confocal laser scanning microscope. The variations of IFF were analyzed by the number and area of lacuna. Volumetric bone mineral density (vBMD) and microarchitecture of bones were evaluated by micro-CT. The correlation coefficients between lacuna's number/area and vBMD were also analyzed. According to our experimental results, a 21 days' tail-suspension could cause a decrease of IFF in lumbar, tibia and tailbone and an increase of IFF in ulna. But in parietal bone, it showed no significant change. The vBMD and microarchitecture parameters also decreased in lumbar and tibia and increased in ulna. But in parietal bone and tailbone, it showed no significant change. And correlation analysis showed significant correlation between vBMD and lacuna's number in lumbar, tibia and ulna. Therefore, IFF decrease may be partly contribute to bone loss in tail-suspended rats, and it should be further investigated.

  15. Effects of odanacatib on the radius and tibia of postmenopausal women: improvements in bone geometry, microarchitecture, and estimated bone strength.

    Science.gov (United States)

    Cheung, Angela M; Majumdar, Sharmila; Brixen, Kim; Chapurlat, Roland; Fuerst, Thomas; Engelke, Klaus; Dardzinski, Bernard; Cabal, Antonio; Verbruggen, Nadia; Ather, Shabana; Rosenberg, Elizabeth; de Papp, Anne E

    2014-08-01

    The cathepsin K inhibitor odanacatib (ODN), currently in phase 3 development for postmenopausal osteoporosis, has a novel mechanism of action that reduces bone resorption while maintaining bone formation. In phase 2 studies, odanacatib increased areal bone mineral density (aBMD) at the lumbar spine and total hip progressively over 5 years. To determine the effects of ODN on cortical and trabecular bone and estimate changes in bone strength, we conducted a randomized, double-blind, placebo-controlled trial, using both quantitative computed tomography (QCT) and high-resolution peripheral (HR-p)QCT. In previously published results, odanacatib was superior to placebo with respect to increases in trabecular volumetric BMD (vBMD) and estimated compressive strength at the spine, and integral and trabecular vBMD and estimated strength at the hip. Here, we report the results of HR-pQCT assessment. A total of 214 postmenopausal women (mean age 64.0 ± 6.8 years and baseline lumbar spine T-score -1.81 ± 0.83) were randomized to oral ODN 50 mg or placebo, weekly for 2 years. With ODN, significant increases from baseline in total vBMD occurred at the distal radius and tibia. Treatment differences from placebo were also significant (3.84% and 2.63% for radius and tibia, respectively). At both sites, significant differences from placebo were also found in trabecular vBMD, cortical vBMD, cortical thickness, cortical area, and strength (failure load) estimated using finite element analysis of HR-pQCT scans (treatment differences at radius and tibia = 2.64% and 2.66%). At the distal radius, odanacatib significantly improved trabecular thickness and bone volume/total volume (BV/TV) versus placebo. At a more proximal radial site, odanacatib attenuated the increase in cortical porosity found with placebo (treatment difference = -7.7%, p = 0.066). At the distal tibia, odanacatib significantly improved trabecular number, separation, and BV/TV versus placebo. Safety

  16. The relationship between developmental lumbar spinal stenosis and its BMD value : comparison by single energy quantitative CT

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hak Jin; Kim, Kun Il; Song, Keun Sung [Pusan National Univ. Hospital, Pusan (Korea, Republic of)

    1996-03-01

    The purpose of this study is to evaluate the relationship between developmental lumbar spinal stenosis and its BMD value by using the single energy quantitative CT(SEQCT). Eighty normal volunteers(20-60years) were selected as a control group and 28 patients with developmental lumbar spinal stenosis were selected as a disease group. The two groups were divided into a younger (20-39 years) and an older subgroup (40-60 years), and were further divided into male and female subgroups. All the cases showed no evidence of metabolic disease, fracture, herniated nucleus pulposus, degererative spondylosis, infectious disease, tumors or had no history of absolute immobilization of more than two weeks. All underwent lumbar spine CT and SEQCT. we measured bone mineral density(BMD) at the cancellous bone of L1, 2, 3 and obtained the mean and its one standard deviation, and compared the data between each sub-group of the control and the disease group using ANOVA. There was a significant low BMD value in the younger male patient subgroup compared with the control subgroup(p<0.005). Developmental lumbar spinal stenosis in a young male may be a factor of decreasing BMD of the body of the spine.

  17. Missile Defense in the 21st Century Acquisition Environment: Exploring a BMD-Capable LCS Mission Package

    Science.gov (United States)

    2013-09-01

    the littoral BMD mission. The sea state, wind speed, precipitation, and cloud cover for the DRM region was estimated using data for the Gulf of Sidra ...civilian air traffic with the area surrounding the Gulf of Sidra having 144 airports, 64 of those being paved (CIA World Fact Book, 2012). The large

  18. Femoral geometric parameters and BMD measurements by DXA in adult patients with different types of osteogenesis imperfecta.

    Science.gov (United States)

    Kocijan, Roland; Muschitz, Christian; Fratzl-Zelman, Nadja; Haschka, Judith; Dimai, Hans-Peter; Trubrich, Angela; Bittighofer, Christina; Resch, Heinrich

    2013-02-01

    Osteogenesis imperfecta (OI) is an inherited disorder characterized by increased bone fragility with recurrent fractures that leads to skeletal deformities in severe cases. Consequently, in most OI patients, the hip is the only reliable measuring site for estimating future fracture risk. The aim of the study was to assess the applicability of hip structure analysis (HSA) by DXA in adult patients with osteogenesis imperfecta. We evaluated bone mineral density (BMD) and hip structure analysis (HSA) by DXA, including cross-sectional area (CSA), cross-sectional moment of inertia (CSMI) and femoral strength index (FSI) in 30 adult patients with different types of OI and 30 age-matched healthy controls (CO). The OI total group (OI-tot) was divided into two subgroups: the mild OI I group (OI-I) and the more severe OI III and IV group (OI-III-IV). The mean neck BMD of OI-I and OI-III-IV were significantly lower compared to CO (-15.9 %, p osteogenesis imperfecta and controls. BMD measurement in osteogenesis imperfecta patients is very critical. The combination of BMD and geometric structural measurements at the hip in osteogenesis imperfecta patients may represent an additional helpful means in estimating bone strength and fracture risk.

  19. Functional autonomy, bone mineral density (BMD) and serum osteocalcin levels in older female participants of an aquatic exercise program (AAG).

    Science.gov (United States)

    Pernambuco, Carlos Soares; Borba-Pinheiro, Claudio Joaquim; Vale, Rodrigo Gomes de Souza; Di Masi, Fabrizio; Monteiro, Paola Karynne Pinheiro; Dantas, Estelio H M

    2013-01-01

    The aim of the present study was to evaluate the effects of an AAG on BMD, osteocalcin and functional autonomy in older women. The sample consisted of eighty-two post-menopausal women with low BMD, randomly divided into two groups: the Aquatic Aerobics Group [AAG; n=42; age: 66.8±4.2years], submitted to two weekly sessions over eight months, and the Control Group (GC; n=42; age: 66.9±3.2years), which did not participate in regular exercise. BMD was measured by Dual Energy X-ray Absorptiometry [DXA] of the lumbar and femur, and serum osteocalcin was measured using electrochemiluminescence. A functional autonomy assessment protocol (GDLAM, 2004) was also applied. Statistical analyses used were repeated measures ANOVA and Tukey's post hoc tests. The results showed a significant improvement in tests following the GDLAM protocol: 10 meters walk (10mw) -p=0.003; rising from a ventral decubitus position (RVDP) - Δ%=0.78, paquatic aerobic exercise program can improve functional autonomy and osteocalcin levels, although training did not improve lumbar and total femur BMD in the older women.

  20. Effects of increasing age, dosage, and duration of PTH treatment on BMD increase--a meta-analysis

    DEFF Research Database (Denmark)

    Schwarz, Peter; Jorgensen, Niklas Rye; Mosekilde, Leif;

    2012-01-01

    We studied the effects of increasing age, dosage, and duration of parathyroid hormone (PTH) treatment on changes in bone mineral density (BMD). Randomized placebo controlled trials on PTH treatment in men or women were retrieved from PubMed (1951 to present), Web of Science (1945 to present...

  1. Low bone turnover and low BMD in Down syndrome: effect of intermittent PTH treatment.

    Directory of Open Access Journals (Sweden)

    Tristan W Fowler

    Full Text Available Trisomy 21 affects virtually every organ system and results in the complex clinical presentation of Down syndrome (DS. Patterns of differences are now being recognized as patients' age and these patterns bring about new opportunities for disease prevention and treatment. Low bone mineral density (BMD has been reported in many studies of males and females with DS yet the specific effects of trisomy 21 on the skeleton remain poorly defined. Therefore we determined the bone phenotype and measured bone turnover markers in the murine DS model Ts65Dn. Male Ts65Dn DS mice are infertile and display a profound low bone mass phenotype that deteriorates with age. The low bone mass was correlated with significantly decreased osteoblast and osteoclast development, decreased bone biochemical markers, a diminished bone formation rate and reduced mechanical strength. The low bone mass observed in 3 month old Ts65Dn mice was significantly increased after 4 weeks of intermittent PTH treatment. These studies provide novel insight into the cause of the profound bone fragility in DS and identify PTH as a potential anabolic agent in the adult low bone mass DS population.

  2. Screening of Dystrophin Gene Deletions in Egyptian Patients with DMD/BMD Muscular Dystrophies

    Directory of Open Access Journals (Sweden)

    Laila K. Effat

    2000-01-01

    Full Text Available Duchenne muscular dystrophy (DMD and Becker muscular dystrophy (BMD are allelic disorders caused by mutations within the dystrophin gene. Our study has identified 100 Egyptian families collected from the Human Genetics Clinic, National Research Center, Cairo. All cases were subjected to complete clinical evaluation pedigree analysis, electromyography studies, estimation of serum creatine phosphokinase enzyme (CPK levels and DNA analysis. Multiplex PCR using 18 pairs of specific primers were used for screening of deletion mutations within the dystrophin gene. A frequency of 55% among the families. Sixty per cent of detected deletions involved multiple exons spanning the major or the minor hot spot of the dystrophin gene. The remainder 40% which mainly involved exon 45. Comparing these findings with frequencies of other countries it was found that our figures fall within the reported range of 40%– for deletions. The distribution of deletions in our study and other different studies was variable and specific ethnic differences do not apparently account for specific deletions. In addition this study concluded that employment of the 18 exon analysis is a cost effective and a highly accurate (97% to launch a nationwide program.

  3. Gene receptor polymorphism as a risk factor for BMD deterioration in adolescent girls with anorexia nervosa.

    Science.gov (United States)

    Stergioti, E; Deligeoroglou, E; Economou, E; Tsitsika, A; Dimopoulos, K D; Daponte, A; Katsioulis, A; Creatsas, G

    2013-07-01

    Anorexia nervosa is a serious eating disorder that is associated with decreased bone mineral density and greater lifetime risk for fractures. This case-controlled study, analyzed single nucleotide polymorphisms of genes encoding vitamin D receptor, estrogen receptor alpha (ESR1), collagen type I and calcitonin receptor (CTR). Relationships between genotype and body mass index, cycling status and lumbar spine bone mineral density (LBMD) were determined in 40 adolescent girls with anorexia nervosa and 10 age-matched controls. The distribution of CTR-AluI genotypes differed between groups, but this polymorphism was not associated with LBMD Z-score. Distribution of ESR1-XbaI genotypes did not differ between groups, but the AA genotype was associated with decreased LBMD Z-score (≤-1) (OR = 24.79, 95% CI, 1.01-606.08). Carriers of the A allele were more likely to have decreased LBMD Z-scores compared with carriers of the G allele (OR = 4.12, 95% CI, 1.23-13.85, p = 0.022). In conclusion, our study shows that anorexic patients with wild-type genotype ESR-XbaI receptor are in greater risk for decreased BMD in relation to those with the mutated gene. Prompt recognition of these patients is crucial because early administration of the proper therapeutic treatment may contribute to the prevention of adverse sequelae on bone metabolism.

  4. Nonequilibrium volumetric response of shocked polymers

    Energy Technology Data Exchange (ETDEWEB)

    Clements, B E [Los Alamos National Laboratory

    2009-01-01

    Polymers are well known for their non-equilibrium deviatoric behavior. However, investigations involving both high rate shock experiments and equilibrium measured thermodynamic quantities remind us that the volumetric behavior also exhibits a non-equilibrium response. Experiments supporting the notion of a non-equilibrium volumetric behavior will be summarized. Following that discussion, a continuum-level theory is proposed that will account for both the equilibrium and non-equilibrium response. Upon finding agreement with experiment, the theory is used to study the relaxation of a shocked polymer back towards its shocked equilibrium state.

  5. Bone Indices in Thyroidectomized Patients on Long-Term Substitution Therapy with Levothyroxine Assessed by DXA and HR-pQCT

    Directory of Open Access Journals (Sweden)

    Emil Moser

    2015-01-01

    Full Text Available Background. Studies on bone effects of long-term substitution therapy with levothyroxine (LT4 have shown discrepant results. Previous studies have, however, not evaluated volumetric bone mineral densities (vBMD, bone structure, and strength using high resolution peripheral quantitative computed tomography (HR-pQCT and finite element analysis (FEA. Using a cross-sectional design, we aimed to determine whether BMD, structure, and strength are affected in hypothyroid patients on LT4 substitution therapy. Methods. We compared 49 patients with well-substituted hypothyroidism with 49 age- and gender-matched population based controls. Areal BMD was assessed by DXA, vBMD and bone geometry by HR-pQCT, and bone strength by FEA. Results. Patients had been thyroidectomized due to thyroid cancer (10% and nontoxic (33% or toxic goiter (57%. 82% were women. TSH levels did not differ between groups, but patients had significantly higher levels of T4 (p<0.001 and lower levels of T3 (p<0.01. Compared to controls, patients had higher levels of magnesium (p<0.05, whereas ionized calcium and PTH were lower (p<0.05. Bone scans did not reveal any differences in BMD, bone geometry, or strength. Conclusion. If patients with hypothyroidism are well-substituted with LT4, the disease does not affect bone indices to any major degree.

  6. Changes in bone mineral density (BMD) around the cemented Exeter stem: a prospective study in 18 women with 5 years follow-up

    DEFF Research Database (Denmark)

    Damborg, Frank Lindhøj; Nissen, Nis; Jørgensen, Hans R I

    2008-01-01

    THA changes the pattern of strain distribution in the proximal femur. We quantified the changes in BMD for 5 years after insertion of the cemented Exeter stem in women.......THA changes the pattern of strain distribution in the proximal femur. We quantified the changes in BMD for 5 years after insertion of the cemented Exeter stem in women....

  7. Process conditions and volumetric composition in composites

    DEFF Research Database (Denmark)

    Madsen, Bo

    2013-01-01

    The obtainable volumetric composition in composites is linked to the gravimetric composition, and it is influenced by the conditions of the manufacturing process. A model for the volumetric composition is presented, where the volume fractions of fibers, matrix and porosity are calculated as a fun...... is increased. Altogether, the model is demonstrated to be a valuable tool for a quantitative analysis of the effect of process conditions. Based on the presented findings and considerations, examples of future work are mentioned for the further improvement of the model.......The obtainable volumetric composition in composites is linked to the gravimetric composition, and it is influenced by the conditions of the manufacturing process. A model for the volumetric composition is presented, where the volume fractions of fibers, matrix and porosity are calculated...... as a function of the fiber weight fraction, and where parameters are included for the composite microstructure, and the fiber assembly compaction behavior. Based on experimental data of composites manufactured with different process conditions, together with model predictions, different types of process related...

  8. Indexing Volumetric Shapes with Matching and Packing.

    Science.gov (United States)

    Koes, David Ryan; Camacho, Carlos J

    2015-04-01

    We describe a novel algorithm for bulk-loading an index with high-dimensional data and apply it to the problem of volumetric shape matching. Our matching and packing algorithm is a general approach for packing data according to a similarity metric. First an approximate k-nearest neighbor graph is constructed using vantage-point initialization, an improvement to previous work that decreases construction time while improving the quality of approximation. Then graph matching is iteratively performed to pack related items closely together. The end result is a dense index with good performance. We define a new query specification for shape matching that uses minimum and maximum shape constraints to explicitly specify the spatial requirements of the desired shape. This specification provides a natural language for performing volumetric shape matching and is readily supported by the geometry-based similarity search (GSS) tree, an indexing structure that maintains explicit representations of volumetric shape. We describe our implementation of a GSS tree for volumetric shape matching and provide a comprehensive evaluation of parameter sensitivity, performance, and scalability. Compared to previous bulk-loading algorithms, we find that matching and packing can construct a GSS-tree index in the same amount of time that is denser, flatter, and better performing, with an observed average performance improvement of 2X.

  9. Effect of dietary B vitamins on BMD and risk of fracture in elderly men and women: the Rotterdam study.

    Science.gov (United States)

    Yazdanpanah, Nahid; Zillikens, M Carola; Rivadeneira, Fernando; de Jong, Robert; Lindemans, Jan; Uitterlinden, André G; Pols, Huibert A P; van Meurs, Joyce B J

    2007-12-01

    A mildly elevated homocysteine (Hcy) level is a novel and potentially modifiable risk factor for age-related osteoporotic fractures. Elevated Hcy levels can have a nutritional cause, such as inadequate intake of folate, riboflavin, pyridoxine or cobalamin, which serve as cofactors or substrates for the enzymes involved in the Hcy metabolism. We examined the association between intake of Hcy-related B vitamin (riboflavin, pyridoxine, folate and cobalamin) and femoral neck bone mineral density BMD (FN-BMD) and the risk of fracture in a large population-based cohort of elderly Caucasians. We studied 5304 individuals aged 55 years and over from the Rotterdam Study. Dietary intake of nutrients was obtained from food frequency questionnaires. Incident non-vertebral fractures were recorded during a mean follow-up period of 7.4 years, and vertebral fractures were assessed by X-rays during a mean follow-up period of 6.4 years. We observed a small but significant positive association between dietary pyridoxine (beta = 0.09, p = 1 x 10(-8)) and riboflavin intake (beta = 0.06, p = 0.002) and baseline FN-BMD. In addition, after controlling for gender, age and BMI, pyridoxine intake was inversely correlated to fracture risk. As compared to the three lowest quartiles, individuals in the highest quartile of age- and energy-adjusted dietary pyridoxine intake had a decreased risk of non-vertebral fractures (HR = 0.77, 95% CI = 0.65-0.92, p = 0.005) and of fragility fractures (HR = 0.55, 95% CI = 0.40-0.77, p = 0.0004). Further adjustments for other dietary B vitamins (riboflavin, folate and cobalamin), dietary intake of calcium, vitamin D, vitamin A and vitamin K, protein and energy intake, smoking and BMD did not essentially modify these results. We conclude that increased dietary riboflavin and pyridoxine intake was associated with higher FN-BMD. Furthermore, we found a reduction in risk of fracture in relation to dietary pyridoxine intake independent of BMD. These findings

  10. Development and Application of ECG Acquisition System Based on BMD101 Chip%基于BMD101芯片的心电采集器的开发和应用

    Institute of Scientific and Technical Information of China (English)

    王廷宇; 高军晖

    2015-01-01

    该文利用BMD101芯片,开发了一套心电测量系统。整个系统由心电数据采集及分析软件(运行在Android手机上)、BMD心电采集器、贴敷电极组成。利用这套系统,对人群进行心电测试,发现心率随年龄的变化规律。%In this paper,we use BMD101 chipA set of ECG measurement system is developed.(Running on Android)、 ECG acquisition、Electrode composition. Use of the system,ECG test for people,The change of heart rate with age.

  11. Feasibility of flat-panel volumetric computed tomography (fpVCT) in experimental small animal imaging of osteoporosis - initial experience; Erste Erfahrungen mit einem Flaechendetektor-Volumen-CT (fpVCT) in der experimentellen Osteoporosediagnostik am Kleintiermodell

    Energy Technology Data Exchange (ETDEWEB)

    Valencia, R.; Dullin, C.; Herrmann, K.P.; Kluever, I.; Zaroban, A.; Knollmann, F. [Universitaetsklinikum Goettingen (Germany). Abteilung Diagnostische Radiologie, Goettingen; Stuermer, E.K.; Sehmisch, S. [Universitaetsklinikum Goettingen (Germany). Klinik fuer Unfallchirurgie, Plastische und Wiederherstellungschirurgie; Funke, M. [Klinikum Mittelbaden, Baden-Baden (Germany). Radiologische Klinik an der Stadtklinik

    2006-10-15

    Flat-panel volumetric computed tomography (fpVCT) is a new, noninvasive CT imaging modality with increased isotropic resolution. Technical details, potential applications, and our initial experience with a fpVCT prototype scanner in the imaging of osteoporosis in a rat model are presented. To date, 21 rats have been investigated in vivo with fpVCT. Pharmacologic effects on bone mineral density (BMD) and structure were of special interest. Image evaluation focussed on the second lumbar vertebra and the left femoral bone. To validate measurement results, BMD values calculated with fpVCT were correlated with results of BMD measurements from ashing of the second lumbar vertebra and femoral bones. Our initial results show that fpVCT is capable of detecting differences in BMD between ovariectomized rats treated with estradiol and a control group with high statistical significance (p<0.05), corresponding to ashing as the gold standard. In a rat model, fpVCT imaging is especially useful in longitudinal in vivo investigations of BMD measures. Spatial resolution of up to 150 {mu}m allows imaging of the trabecular structure only in human cadaveric bones. (orig.) [German] Die Flaechendetektor-Volumen-Computertomographie (fpVCT) ist eine neuartige CT-Bildgebungstechnik, die eine gesteigerte isotrope Ortsaufloesung ermoeglicht. In dieser Arbeit wird ueber Technik, Anwendungsmoeglichkeiten und erste Erfahrungen beim Einsatz eines fpVCT-Prototyps in der experimentellen Diagnostik der Osteoporose am Rattenmodell berichtet. Bisher konnten 21 Ratten in vivo am fpVCT untersucht werden. Von besonderem Interesse waren Medikamentenwirkungen auf Knochendichte (''bone mineral density'', BMD) und -struktur. Die Auswertung der gewonnenen Bilddaten fokussierte sich auf den 2. Lendenwirbelkoerper und das linke Femur. Um die Messergebnisse zu ueberpruefen, wurden die mittels fpVCT errechneten BMD-Werte mit den Ergebnissen der Dichtemessung der veraschten 2. LWK und Femora

  12. Tibia and radius bone geometry and volumetric density in obese compared to non-obese adolescents.

    Science.gov (United States)

    Leonard, Mary B; Zemel, Babette S; Wrotniak, Brian H; Klieger, Sarah B; Shults, Justine; Stallings, Virginia A; Stettler, Nicolas

    2015-04-01

    Childhood obesity is associated with biologic and behavioral characteristics that may impact bone mineral density (BMD) and structure. The objective was to determine the association between obesity and bone outcomes, independent of sexual and skeletal maturity, muscle area and strength, physical activity, calcium intake, biomarkers of inflammation, and vitamin D status. Tibia and radius peripheral quantitative CT scans were obtained in 91 obese (BMI>97th percentile) and 51 non-obese adolescents (BMI>5th and Tibia cortical section modulus and calf muscle area Z-scores were greater in obese participants (1.07 and 1.63, respectively, both pTibia and radius trabecular and cortical volumetric BMD did not differ significantly between groups. Calf muscle area and strength Z-scores, advanced skeletal maturity, and physical activity (by accelerometry) were positively associated with tibia cortical section modulus Z-scores (all ptibia section modulus Z-scores between obese and non-obese participants from 1.07 to 0.28. After multivariate adjustment for greater calf muscle area and strength Z-scores, advanced maturity, and less moderate to vigorous physical activity, tibia section modulus Z-scores were 0.32 (95% CI -0.18, 0.43, p=0.06) greater in obese, vs. non-obese participants. Radius cortical section modulus Z-scores were 0.45 greater (p=0.08) in obese vs. non-obese participants; this difference was attenuated to 0.14 with adjustment for advanced maturity. These findings suggest that greater tibia cortical section modulus in obese adolescents is attributable to advanced skeletal maturation and greater muscle area and strength, while less moderate to vigorous physical activities offset the positive effects of these covariates. The impact of obesity on cortical structure was greater at weight bearing sites.

  13. Contribution of Myostatin gene polymorphisms to normal variation in lean mass, fat mass and peak BMD in Chinese male offspring

    Institute of Scientific and Technical Information of China (English)

    Hua YUE; Miao LI; Yu-juan LIU; Song-hua WU; Zhen-lin ZHANG; Jin-wei HE; Hao ZHANG; Chun WANG; Wei-wei HU; Jie-mei GU; Yao-hua KE; Wen-zhen FU; Yun-qiu HU

    2012-01-01

    Myostatin gene is a member of the transforming growth factor-β (TGF-β) family that negatively regulates skeletal muscle growth.Genetic polymorphisms in Myostatin were found to be associated with the peak bone mineral density (BMD) in Chinese women.The purpose of this study was to investigate whether Myostatin played a role in the normal variation in peak BMD,lean mass (LM),and fat mass (FM) of Chinese men.Methods:Four hundred male-offspring nuclear families of Chinese Han ethnic group were recruited.Anthropometric measurements,includingthe peak BMD,body LM and FM were measured using dual-energy X-ray absorptiometry (DXA).The single nucleotide polymorphisms (SNPs) studied were tag-SNPs selected by sequencing.Both rs2293284 and +2278G>A were genotyped using TaqMan assay,and rs3791783 was genotyped with PCR-restriction fragment length polymorphism (RFLP) analysis.The associations of the SNPs with anthropometfic variations were analyzed using the quantitative transmission disequilibrium test (QTDT).Results:Using QTDT to detect within-family associations,neither single SNP nor haplotype was found to be associated with peak BMD at any bone site.However,rs3791783 was found to be significantly associated with fat mass of the trunk (P<0.001).Moreover,for within-family associations,haplotypes AGG,AAA,and TGG were found to be significantly associated with the trunk fat mass (all P<0.001).Conclusion:Our results suggest that genetic variation within Myostatin may play a role in regulating the variation in fat mass in Chinese males.Additionally,the Myostatin gene may be a candidate that determines body fat mass in Chinese men.

  14. Glutamine repeat variants in human RUNX2 associated with decreased femoral neck BMD, broadband ultrasound attenuation and target gene transactivation.

    Directory of Open Access Journals (Sweden)

    Nigel A Morrison

    Full Text Available RUNX2 is an essential transcription factor required for skeletal development and cartilage formation. Haploinsufficiency of RUNX2 leads to cleidocranial displaysia (CCD a skeletal disorder characterised by gross dysgenesis of bones particularly those derived from intramembranous bone formation. A notable feature of the RUNX2 protein is the polyglutamine and polyalanine (23Q/17A domain coded by a repeat sequence. Since none of the known mutations causing CCD characterised to date map in the glutamine repeat region, we hypothesised that Q-repeat mutations may be related to a more subtle bone phenotype. We screened subjects derived from four normal populations for Q-repeat variants. A total of 22 subjects were identified who were heterozygous for a wild type allele and a Q-repeat variant allele: (15Q, 16Q, 18Q and 30Q. Although not every subject had data for all measures, Q-repeat variants had a significant deficit in BMD with an average decrease of 0.7SD measured over 12 BMD-related parameters (p = 0.005. Femoral neck BMD was measured in all subjects (-0.6SD, p = 0.0007. The transactivation function of RUNX2 was determined for 16Q and 30Q alleles using a reporter gene assay. 16Q and 30Q alleles displayed significantly lower transactivation function compared to wild type (23Q. Our analysis has identified novel Q-repeat mutations that occur at a collective frequency of about 0.4%. These mutations significantly alter BMD and display impaired transactivation function, introducing a new class of functionally relevant RUNX2 mutants.

  15. Volumetric properties of magnesium silicate glasses and supercooled liquid at high pressure by X-ray microtomography

    Energy Technology Data Exchange (ETDEWEB)

    Lesher, Charles E.; Wang, Yanbin; Gaudio, Sarah; Clark, Alisha; Nishiyama, Nori; Rivers, Mark; (UCD); (UC)

    2009-06-01

    The volumetric properties of silicate glasses and supercooled liquid are examined at high pressures and temperatures using X-ray computed tomography (CT) and absorption. The high pressure X-ray microtomography (HPXMT) system at the Advanced Photon Source, Argonne National Laboratory (GeoSoilEnvironCARS 13-BM-D beamline) consists of two opposing anvils compressed within an X-ray-transparent containment ring supported by thrust bearings and loaded using a 250-ton hydraulic press. This system permits the pressure cell to rotate under the load, while collecting radiographs through at least 180{sup o} of rotation. The 13-BM-D beamline permits convenient switching between monochromatic radiation required for radiography and polychromatic radiation for pressure determination by energy dispersive diffraction. We report initial results on several refractory magnesium silicate glasses synthesized by levitation laser heating. Volume changes during room temperature compression of Mg-silicate glasses with 33 mol% and 38 mol% SiO2 up to 11.5 GPa give an isothermal bulk moduli of 93--100 GPa for a K' of 1. These values are consistent with ultrasonic measurements of more silica-rich glasses. The volumetric properties of amorphous MgSiO{sub 3} at 2 GPa were examined during annealing up to 1000 C. We consider the consequences of heating through the glass transition and the implications for thermal expansivity of supercooled liquids at high pressure. Our results illustrate the capabilities of HPXMT for studies of refractory glasses and liquids at high pressure and offer strategies for future studies of liquid densities within the melting interval for magmas in planet interiors.

  16. Combined surface and volumetric occlusion shading

    KAUST Repository

    Schott, Matthias O.

    2012-02-01

    In this paper, a method for interactive direct volume rendering is proposed that computes ambient occlusion effects for visualizations that combine both volumetric and geometric primitives, specifically tube shaped geometric objects representing streamlines, magnetic field lines or DTI fiber tracts. The proposed algorithm extends the recently proposed Directional Occlusion Shading model to allow the rendering of those geometric shapes in combination with a context providing 3D volume, considering mutual occlusion between structures represented by a volume or geometry. © 2012 IEEE.

  17. Are adult patients with Laron syndrome osteopenic? A comparison between dual-energy X-ray absorptiometry and volumetric bone densities.

    Science.gov (United States)

    Benbassat, Carlos A; Eshed, Varda; Kamjin, Moshe; Laron, Zvi

    2003-10-01

    Severe short stature resulting from a deficiency in IGF-I is a prominent feature of Laron syndrome (LS). Although low bone mineral density (BMD) has been noted in LS patients examined by dual energy x-ray absorptiometry (DEXA), this technique does not take volume into account and may therefore underestimate the true bone density in patients with small bones. The aim of the present study was to evaluate the BMD yielded by DEXA in our LS patients using estimated volumetric values. Volumetric density was calculated with the following formulas: bone mineral apparent density (BMAD) = bone mineral content (BMC)/(area)(3/2) for the lumbar spine and BMAD = BMC/area(2) for the femoral neck. The study sample included 12 patients (mean age, 43.9 yr; mean height, 123.7 cm). Findings were compared with 10 osteopenic subjects without developmental abnormalities (mean age, 56 yr; mean height, 164.8 cm) and 10 healthy control subjects matched for sex and age to the LS patients (mean height, 165.5 cm). BMAD in the LS group was 0.201 +/- 0.02 g/cm(3) at the lumbar spine and 0.201 +/- 0.04 g/cm(3) at the femoral neck; corresponding values for the osteopenic group were 0.130 +/- 0.01 and 0.140 +/- 0.01 g/cm(3), and for the controls, 0.178 +/- 0.03 and 0.192 +/- 0.02 g/cm(3). Although areal BMD was significantly lower in the LS and osteopenic subjects compared with controls (P < 0.02) at both the lumbar spine and femoral neck, BMAD was low (P < 0.01) in the osteopenic group only. In conclusion, DEXA does not seem to be a reliable measure of osteoporosis in patients with LS.

  18. Association Between Insulin Resistance and Bone Structure in Nondiabetic Postmenopausal Women

    DEFF Research Database (Denmark)

    Shanbhogue, Vikram V; Finkelstein, Joel S; Bouxsein, Mary L

    2016-01-01

    CONTEXT: The clinical consequences of insulin resistance and hyperinsulinemia on bone remain largely unknown. OBJECTIVE: To evaluate the effect of insulin resistance on peripheral bone geometry, volumetric bone mineral density (vBMD), bone microarchitecture and estimated bone strength. DESIGN......, SETTING AND PARTICIPANTS: This cross-sectional study included 146 postmenopausal, non-diabetic Caucasian women (mean age 60.3 ± 2.7 years) who were participating in the Study of Women's Health Across the Nation (SWAN). INTERVENTIONS: None Main outcome measures: High-resolution peripheral quantitative...... bone density and favorable trabecular microarchitecture seen in individuals with type 2 diabetes mellitus....

  19. MR volumetric assessment of endolymphatic hydrops

    Energy Technology Data Exchange (ETDEWEB)

    Guerkov, R.; Berman, A.; Jerin, C.; Krause, E. [University of Munich, Department of Otorhinolaryngology Head and Neck Surgery, Grosshadern Medical Centre, Munich (Germany); University of Munich, German Centre for Vertigo and Balance Disorders, Grosshadern Medical Centre, Marchioninistr. 15, 81377, Munich (Germany); Dietrich, O.; Flatz, W.; Ertl-Wagner, B. [University of Munich, Institute of Clinical Radiology, Grosshadern Medical Centre, Munich (Germany); Keeser, D. [University of Munich, Institute of Clinical Radiology, Grosshadern Medical Centre, Munich (Germany); University of Munich, German Centre for Vertigo and Balance Disorders, Grosshadern Medical Centre, Marchioninistr. 15, 81377, Munich (Germany); University of Munich, Department of Psychiatry and Psychotherapy, Innenstadtkliniken Medical Centre, Munich (Germany)

    2014-10-16

    We aimed to volumetrically quantify endolymph and perilymph spaces of the inner ear in order to establish a methodological basis for further investigations into the pathophysiology and therapeutic monitoring of Meniere's disease. Sixteen patients (eight females, aged 38-71 years) with definite unilateral Meniere's disease were included in this study. Magnetic resonance (MR) cisternography with a T2-SPACE sequence was combined with a Real reconstruction inversion recovery (Real-IR) sequence for delineation of inner ear fluid spaces. Machine learning and automated local thresholding segmentation algorithms were applied for three-dimensional (3D) reconstruction and volumetric quantification of endolymphatic hydrops. Test-retest reliability was assessed by the intra-class coefficient; correlation of cochlear endolymph volume ratio with hearing function was assessed by the Pearson correlation coefficient. Endolymph volume ratios could be reliably measured in all patients, with a mean (range) value of 15 % (2-25) for the cochlea and 28 % (12-40) for the vestibulum. Test-retest reliability was excellent, with an intra-class coefficient of 0.99. Cochlear endolymphatic hydrops was significantly correlated with hearing loss (r = 0.747, p = 0.001). MR imaging after local contrast application and image processing, including machine learning and automated local thresholding, enable the volumetric quantification of endolymphatic hydrops. This allows for a quantitative assessment of the effect of therapeutic interventions on endolymphatic hydrops. (orig.)

  20. Comparison of the broth microdilution (BMD) method of the European Committee on Antimicrobial Susceptibility Testing with the 24-hour CLSI BMD method for testing susceptibility of Candida species to fluconazole, posaconazole, and voriconazole by use of epidemiological cutoff values.

    Science.gov (United States)

    Pfaller, M A; Espinel-Ingroff, A; Boyken, L; Hollis, R J; Kroeger, J; Messer, S A; Tendolkar, S; Diekema, D J

    2011-03-01

    The antifungal broth microdilution (BMD) method of the European Committee on Antimicrobial Susceptibility Testing (EUCAST) was compared with CLSI BMD method M27-A3 for fluconazole, posaconazole, and voriconazole susceptibility testing of 1,056 isolates of Candida. The isolates were obtained in 2009 from more than 60 centers worldwide and included 560 isolates of C. albicans, 175 of C. glabrata, 162 of C. parapsilosis, 124 of C. tropicalis, and 35 of C. krusei. The overall essential agreement (EA) between EUCAST and CLSI results ranged from 96.9% (voriconazole) to 98.6% (fluconazole). The categorical agreement (CA) between methods and species of Candida was assessed using previously determined epidemiological cutoff values (ECVs). The ECVs (expressed as μg/ml) for fluconazole, posaconazole, and voriconazole, respectively, were as follows: 0.12, 0.06, and 0.03 for C. albicans; 32, 2, and 0.5 for C. glabrata; 2, 0.25, and 0.12 for C. parapsilosis; 2, 0.12, and 0.06 for C. tropicalis; 64, 0.5, and 0.5 for C. krusei. Excellent CA was observed for all comparisons between the EUCAST and CLSI results for fluconazole, posaconazole, and voriconazole, respectively, for each species: 98.9%, 93.6%, and 98.6% for C. albicans; 96.0%, 98.9%, and 93.7% for C. glabrata; 90.8%, 98.1%, and 98.1% for C. parapsilosis; 99.2%, 99.2%, and 96.8% for C. tropicalis; 97.1%, 97.1%, and 97.1% for C. krusei. We demonstrate high levels of EA and CA between the CLSI and EUCAST BMD methods for testing of triazoles against Candida when the MICs were determined after 24 h and ECVs were used to differentiate wild-type (WT) from non-WT strains. These results provide additional data in favor of the harmonization of these two methods.

  1. Comparison of the Broth Microdilution (BMD) Method of the European Committee on Antimicrobial Susceptibility Testing with the 24-Hour CLSI BMD Method for Testing Susceptibility of Candida Species to Fluconazole, Posaconazole, and Voriconazole by Use of Epidemiological Cutoff Values▿

    Science.gov (United States)

    Pfaller, M. A.; Espinel-Ingroff, A.; Boyken, L.; Hollis, R. J.; Kroeger, J.; Messer, S. A.; Tendolkar, S.; Diekema, D. J.

    2011-01-01

    The antifungal broth microdilution (BMD) method of the European Committee on Antimicrobial Susceptibility Testing (EUCAST) was compared with CLSI BMD method M27-A3 for fluconazole, posaconazole, and voriconazole susceptibility testing of 1,056 isolates of Candida. The isolates were obtained in 2009 from more than 60 centers worldwide and included 560 isolates of C. albicans, 175 of C. glabrata, 162 of C. parapsilosis, 124 of C. tropicalis, and 35 of C. krusei. The overall essential agreement (EA) between EUCAST and CLSI results ranged from 96.9% (voriconazole) to 98.6% (fluconazole). The categorical agreement (CA) between methods and species of Candida was assessed using previously determined epidemiological cutoff values (ECVs). The ECVs (expressed as μg/ml) for fluconazole, posaconazole, and voriconazole, respectively, were as follows: 0.12, 0.06, and 0.03 for C. albicans; 32, 2, and 0.5 for C. glabrata; 2, 0.25, and 0.12 for C. parapsilosis; 2, 0.12, and 0.06 for C. tropicalis; 64, 0.5, and 0.5 for C. krusei. Excellent CA was observed for all comparisons between the EUCAST and CLSI results for fluconazole, posaconazole, and voriconazole, respectively, for each species: 98.9%, 93.6%, and 98.6% for C. albicans; 96.0%, 98.9%, and 93.7% for C. glabrata; 90.8%, 98.1%, and 98.1% for C. parapsilosis; 99.2%, 99.2%, and 96.8% for C. tropicalis; 97.1%, 97.1%, and 97.1% for C. krusei. We demonstrate high levels of EA and CA between the CLSI and EUCAST BMD methods for testing of triazoles against Candida when the MICs were determined after 24 h and ECVs were used to differentiate wild-type (WT) from non-WT strains. These results provide additional data in favor of the harmonization of these two methods. PMID:21227994

  2. Structure and strength of the distal radius in female patients with rheumatoid arthritis: a case-control study.

    Science.gov (United States)

    Zhu, Tracy Y; Griffith, James F; Qin, Ling; Hung, Vivian W Y; Fong, Tsz-Ning; Au, Sze-Ki; Tang, Xiao Lin; Kwok, Anthony W; Leung, Ping-Chung; Li, Edmund K; Tam, Lai-Shan

    2013-04-01

    The purpose of this work was to investigate the volumetric bone mineral density (vBMD), bone microstructure, and mechanical indices of the distal radius in female patients with rheumatoid arthritis (RA). We report a cross-sectional study of 66 middle-aged female RA patients and 66 age-matched healthy females. Areal BMD (aBMD) of the hip, lumbar spine, and distal radius was measured by dual-energy X-ray absorptiometry (DXA). High-resolution peripheral quantitative computed tomography (HR-pQCT) was performed at the distal radius, yielding vBMD, bone microstructure, and mechanical indices. Cortical and trabecular vBMD were 3.5% and 10.7% lower, respectively, in RA patients than controls, despite comparable aBMD. Trabecular microstructural indices were -5.7% to -23.1% inferior, respectively, in RA patients compared to controls, with significant differences in trabecular bone volume fraction, separation, inhomogeneity, and structural model index. Cortical porosity volume and percentage were 128% and 93% higher, respectively, in RA patients, with stress being distributed more unevenly. Fourteen RA patients had exaggerated periosteal bone apposition primarily affecting the ulnovolar aspect of the distal radius. These particular patients were more likely to have chronic and severe disease and coexisting wrist deformity. The majority of the differences in density and microstructure between RA patients and controls did not depend on menstrual status. Recent exposure to glucocorticoids did not significantly affect bone density and microstructure. HR-pQCT provides new insight into inflammation-associated bone fragility in RA. It detects differences in vBMD, bone microstructure, and mechanical indices that are not captured by DXA. At the distal radius, deterioration in density and microstructure in RA patients involved both cortical and trabecular compartments. Excessive bone resorption appears to affect cortical more than trabecular bone at distal radius, particularly

  3. A study on the effects of a calcium drug on the bone mineral density (BMD) by using dual-energy X-ray Absorptiometry (DXA)

    Science.gov (United States)

    Kim, Eun-Hye; Kim, Ho-Sung; Dong, Kyung-Rae; Park, Yong-Soon; Chung, Woon-Kwan; Cho, Jae-Hwan

    2012-12-01

    Measurements of osteoporosis might contain errors caused by the calcium drug used in the prevention and the treatment of osteoporosis. This study conducted a lumbar spine phantom experiment to examine whether a calcium drug can influence the measured values of the bone mineral density (BMD) because of the drug taken by a real patient remaining undigested in the stomach. Dual-energy X-ray Absorptiometry (DXA) was used to measure the BMD for a calcium-drug in an equipment-dedicated lumbar spine phantom and 10 patients selected for the BMD measurement. Three types of drugs that are prescribed in actual clinical practice calcium drugs were used for the phantom experiment, and the drugs were divided into a fixed dose, 1/2 of the fixed dose, 1/4 of the fixed dose and 1/8 of the fixed dose. Without the drugs included, the phantom was scanned 60 times continuously to calculate the baseline BMD. The BMD was measured as the calcium drug coated with paraffin was placed in the lumbar vertebra 2 and the soft tissue region of the phantom. To determine when the drug was invisible to the naked eye are measured, the BMD at different drug dilutions. The measurements were conducted three times to calculate the mean. In the patient experiment, patients were selected who visited hospital after taking the drug before measuring the BMD. After a certain time had passed, the BMD was measured again to examine the difference in images and the change in BMD values due to the calcium-drug intake. The BMD measurements of lumbar 1-4 in the phantom were higher, with statistical significant, than the least significant change (LSC) in the bone region for all three drugs (Ca carbonate, Ca citrate and Ca cholecalciferol), showing a significant increase. On the other hand, there was no significant change in the soft tissue. When Ca Cholecalciferol was used in a fixed dose, the BMD of L2 increased by 11.6%, showing the largest increase among the drugs examined, but only a 2.8% increase in the BMD of L1

  4. Morphological Atherosclerosis Calcification Distribution (MACD) Index is a Strong Predictor of Cardio-Vascular Death and Include Predictive Power of BMD

    DEFF Research Database (Denmark)

    Christiansen, Claus; Karsdal, Morten; Ganz, Melanie;

    followed for 8.3±0.3 years and CVD deaths were recorded. BMD and several aortic calcification markers were computed: number, morphology, distribution, from outlines of the calcified plaques in lumbar X-rays. These markers were compared to BMD, SCORE card, Framingham score, and the Aortic Calcification...... Severity score - AC24. AC24 adjusted by age, waist circumference, and triglyceride levels (ATW) predicted mortality in postmenopausal women (CVD p=0.03, All-cause p=0.006). The SCORE card and the Framingham score resulted in mortality odds ratios (MOR) of 5.0 and 5.2 - defining high risk as =6 and =18......, respectively. BMD and BMD adjusted for ATW was lower in the group of deceased than in survivors (pscores based on the calcification geometry provided highly significant predictions. The number of calcified deposits...

  5. Expanding the Description of Spaceflight Effects beyond Bone Mineral Density [BMD]: Trabecular Bone Score [TBS] in ISS Astronauts

    Science.gov (United States)

    Sibonga, J. D.; Spector, E. R.; King, L. J.; Evans, H. J.; Smith, S. A.

    2014-01-01

    Dual-energy x-ray absorptiometry [DXA] is the widely-applied bone densitometry method used to diagnose osteoporosis in a terrestrial population known to be at risk for age-related bone loss. This medical test, which measures areal bone mineral density [aBMD] of clinically-relevant skeletal sites (e.g., hip and spine), helps the clinician to identify which persons, among postmenopausal women and men older than 50 years, are at high risk for low trauma or fragility fractures and might require an intervention. The most recognized osteoporotic fragility fracture is the vertebral compression fracture which can lead to kyphosis or hunched backs typically seen in the elderly. DXA measurement of BMD however is recognized to be insufficient as a sole index for assessing fracture risk. DXA's limitation may be related to its inability to monitor changes in structural parameters, such as trabecular vs. cortical bone volumes, bone geometry or trabecular microarchitecture. Hence, in order to understand risks to human health and performance due to space exposure, NASA needs to expand its measurements of bone to include other contributors to skeletal integrity. To this aim, the Bone and Mineral Lab conducted a pilot study for a novel measurement of bone microarchitecture that can be obtained by retrospective analysis of DXA scans. Trabecular Bone Score (TBS) assesses changes to trabecular microarchitecture by measuring the grey color "texture" information extracted from DXA images of the lumbar spine. An analysis of TBS in 51 ISS astronauts was conducted to assess if TBS could detect 1) an effect of spaceflight and 2) a response to countermeasures independent of DXA BMD. In addition, changes in trunk body lean tissue mass and in trunk body fat tissue mass were also evaluated to explore an association between body composition, as impacted by ARED exercise, and bone microarchitecture. The pilot analysis of 51 astronaut scans of the lumbar spine suggests that, following an ISS

  6. Sensitivity and Frequencies of Dystrophin Gene Mutations in Thai DMD/BMD Patients As Detected by Multiplex PCR

    Directory of Open Access Journals (Sweden)

    Thanyachai Sura

    2008-01-01

    Full Text Available Background: Duchenne muscular dystrophy (DMD, a lethal X-linked disease affecting 1 in 3500 male births, and its more benign variant, Becker muscular dystrophy (BMD, are caused by mutations in the dystrophin gene. Because of its large size, analysing the whole gene is impractical. Methods have been developed to detect the commonest mutations i.e. the deletions of the exons. Although these tests are highly specific, their sensitivity is inherently limited by the prevalence of deletions, which differs among different populations.

  7. Volumetric polymerization shrinkage of contemporary composite resins

    Directory of Open Access Journals (Sweden)

    Halim Nagem Filho

    2007-10-01

    Full Text Available The polymerization shrinkage of composite resins may affect negatively the clinical outcome of the restoration. Extensive research has been carried out to develop new formulations of composite resins in order to provide good handling characteristics and some dimensional stability during polymerization. The purpose of this study was to analyze, in vitro, the magnitude of the volumetric polymerization shrinkage of 7 contemporary composite resins (Definite, Suprafill, SureFil, Filtek Z250, Fill Magic, Alert, and Solitaire to determine whether there are differences among these materials. The tests were conducted with precision of 0.1 mg. The volumetric shrinkage was measured by hydrostatic weighing before and after polymerization and calculated by known mathematical equations. One-way ANOVA (a or = 0.05 was used to determine statistically significant differences in volumetric shrinkage among the tested composite resins. Suprafill (1.87±0.01 and Definite (1.89±0.01 shrank significantly less than the other composite resins. SureFil (2.01±0.06, Filtek Z250 (1.99±0.03, and Fill Magic (2.02±0.02 presented intermediate levels of polymerization shrinkage. Alert and Solitaire presented the highest degree of polymerization shrinkage. Knowing the polymerization shrinkage rates of the commercially available composite resins, the dentist would be able to choose between using composite resins with lower polymerization shrinkage rates or adopting technical or operational procedures to minimize the adverse effects deriving from resin contraction during light-activation.

  8. A SUBDIVISION SCHEME FOR VOLUMETRIC MODELS

    Institute of Scientific and Technical Information of China (English)

    GhulamMustafa; LiuXuefeng

    2005-01-01

    In this paper, a subdivision scheme which generalizes a surface scheme in previous papers to volume meshes is designed. The scheme exhibits significant control over shrink-age/size of volumetric models. It also has the ability to conveniently incorporate boundaries and creases into a smooth limit shape of models. The method presented here is much simpler and easier as compared to MacCracken and Joy's. This method makes no restrictions on the local topology of meshes. Particularly, it can be applied without any change to meshes of nonmanifold topology.

  9. Volumetric composition in composites and historical data

    DEFF Research Database (Denmark)

    Lilholt, Hans; Madsen, Bo

    2013-01-01

    guidance to the optimal combination of fibre content, matrix content and porosity content, in order to achieve the best obtainable properties. Several composite materials systems have been shown to be handleable with this model. An extensive series of experimental data for the system of cellulose fibres...... and polymer (resin) was produced in 1942 – 1944, and these data have been (re-)analysed by the volumetric composition model, and the property values for density, stiffness and strength have been evaluated. Good agreement has been obtained and some further observations have been extracted from the analysis....

  10. IMITATION OF STANDARD VOLUMETRIC ACTIVITY METAL SAMPLES

    Directory of Open Access Journals (Sweden)

    A. I. Zhukouski

    2016-01-01

    Full Text Available Due to the specific character of problems in the field of ionizing radiation spectroscopy, the R&D and making process of standard volumetric activity metal samples (standard samples for calibration and verification of spectrometric equipment is not only expensive, but also requires the use of highly qualified experts and a unique specific equipment. Theoretical and experimental studies performed have shown the possibility to use imitators as a set of alternating point sources of gamma radiation and metal plates and their use along with standard volumetric activity metal samples for calibration of scintillation-based detectors used in radiation control in metallurgy. Response functions or instrumental spectra of such spectrometer to radionuclides like 137Cs, 134Cs, 152Eu, 154Eu, 60Co, 54Mn, 232Th, 226Ra, 65Zn, 125Sb+125mTe, 106Ru+106Rh, 94Nb, 110mAg, 233U, 234U, 235U and 238U are required for calibration in a given measurement geometry. Standard samples in the form of a probe made of melt metal of a certain diameter and height are used in such measurements. However, the production of reference materials is costly and even problematic for such radionuclides as 94Nb, 125Sb+125mTe, 234U, 235U  etc. A recognized solution to solve this problem is to use the Monte-Carlo simulation method. Instrumental experimental and theoretical spectra obtained by using standard samples and their imitators show a high compliance between experimental spectra of real samples and the theoretical ones of their Monte-Carlo models, between spectra of real samples and the ones of their imitators and finally, between experimental spectra of real sample imitators and the theoretical ones of their Monte-Carlo models. They also have shown the adequacy and consistency of the approach in using a combination of metal scattering layers and reference point gamma-ray sources instead of standard volumetric activity metal samples. As for using several reference point gamma-ray sources

  11. Magnetic volumetric hologram memory with magnetic garnet.

    Science.gov (United States)

    Nakamura, Yuichi; Takagi, Hiroyuki; Lim, Pang Boey; Inoue, Mitsuteru

    2014-06-30

    Holographic memory is a promising next-generation optical memory that has a higher recording density and a higher transfer rate than other types of memory. In holographic memory, magnetic garnet films can serve as rewritable holographic memory media by use of magneto-optical effect. We have now demonstrated that a magnetic hologram can be recorded volumetrically in a ferromagnetic garnet film and that the signal image can be reconstructed from it for the first time. In addition, multiplicity of the magnetic hologram was also confirmed; the image could be reconstructed from a spot overlapped by other spots.

  12. Bone geometry in response to long-term tennis playing and its relationship with muscle volume: a quantitative magnetic resonance imaging study in tennis players.

    Science.gov (United States)

    Ducher, G; Courteix, D; Même, S; Magni, C; Viala, J F; Benhamou, C L

    2005-10-01

    The benefit of impact-loading activity for bone strength depends on whether the additional bone mineral content (BMC) accrued at loaded sites is due to an increased bone size, volumetric bone mineral density (vBMD) or both. Using magnetic resonance imaging (MRI) and dual energy X-ray absorptiometry (DXA), the aim of this study was to characterize the geometric changes of the dominant radius in response to long-term tennis playing and to assess the influence of muscle forces on bone tissue by investigating the muscle-bone relationship. Twenty tennis players (10 men and 10 women, mean age: 23.1+/-4.7 years, with 14.3+/-3.4 years of playing) were recruited. The total bone volume, cortical volume, sub-cortical volume and muscle volume were measured at both distal radii by MRI. BMC was assessed by DXA and was divided by the total bone volume to derive vBMD. Grip strength was evaluated with a dynamometer. Significant side-to-side differences (P<0.0001) were found in muscle volume (+9.7%), grip strength (+13.3%), BMC (+13.5%), total bone volume (+10.3%) and sub-cortical volume (+20.6%), but not in cortical volume (+2.6%, ns). The asymmetry in total bone volume explained 75% of the variance in BMC asymmetry (P<0.0001). vBMD was slightly higher on the dominant side (+3.3%, P<0.05). Grip strength and muscle volume correlated with all bone variables (except vBMD) on both sides (r=0.48-0.86, P<0.05-0.0001) but the asymmetries in muscle parameters did not correlate with those in bone parameters. After adjustment for muscle volume or grip strength, BMC was still greater on the dominant side. This study showed that the greater BMC induced by long-term tennis playing at the dominant radius was associated to a marked increase in bone size and a slight improvement in volumetric BMD, thereby improving bone strength. In addition to the muscle contractions, other mechanical stimuli seemed to exert a direct effect on bone tissue, contributing to the specific bone response to tennis

  13. Vitamin B(12) and folic acid levels as therapeutic target in preserving bone mineral density (BMD) of older men.

    Science.gov (United States)

    Naharci, Ilkin; Bozoglu, Ergun; Karadurmus, Nuri; Emer, Ozdes; Kocak, Necmettin; Kilic, Selim; Doruk, Huseyin; Serdar, Muhittin

    2012-01-01

    The knowledge about vitamin B(12) and folic acid levels in preserving bone mass in older men is limited. In this retrospective study, we aimed to find out whether levels of vitamin B(12) and folic acid are related to BMD in older men. Two hundred and sixty-nine older men were included in the study. Forty-two (15.6%) of them had osteoporotic, 150 (55.8%) had osteopenic, and 77 (28.6%) had normal BMD. Vitamin B(12) and folic acid levels were categorized as indicating normal, borderline, or low vitamin statuses. Femur neck densities showed statistically significant differences in subjects having low, borderline, and normal vitamin B(12), respectively. There were no significant differences between the three tertiles of vitamin B(12) in femur total, trochanteric, and intertrochanteric densities. After adjustment for age, body mass index (BMI), alcohol, smoking, and exercise with analysis of covariance, the difference was still statistically significant between two groups for femur neck density (p=0.011). No significant difference was observed between the groups of folic acid in any femur sites. We found that the normal level of vitamin B(12) in older men may be related to a decrease of femur neck bone loss. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  14. High-resolution peripheral quantitative computed tomography and finite element analysis of bone strength at the distal radius in ovariectomized adult rhesus monkey demonstrate efficacy of odanacatib and differentiation from alendronate.

    Science.gov (United States)

    Cabal, Antonio; Jayakar, Richa Y; Sardesai, Swanand; Phillips, Eual A; Szumiloski, John; Posavec, Diane J; Mathers, Parker D; Savitz, Alan T; Scott, Boyd B; Winkelmann, Christopher T; Motzel, Sherri; Cook, Lynn; Hargreaves, Richard; Evelhoch, Jeffrey L; Dardzinski, Bernard J; Hangartner, Thomas N; McCracken, Paul J; Duong, Le T; Williams, Donald S

    2013-10-01

    Translational evaluation of disease progression and treatment response is critical to the development of therapies for osteoporosis. In this study, longitudinal in-vivo monitoring of odanacatib (ODN) treatment efficacy was compared to alendronate (ALN) in ovariectomized (OVX) non-human primates (NHPs) using high-resolution peripheral computed tomography (HR-pQCT). Treatment effects were evaluated using several determinants of bone strength, density and quality, including volumetric bone mineral density (vBMD), three-dimensional structure, finite element analysis (FEA) estimated peak force and biomechanical properties at the ultradistal (UD) radius at baseline, 3, 6, 9, 12, and 18 months of dosing in three treatment groups: vehicle (VEH), low ODN (2 mg/kg/day, L-ODN), and ALN (30 μg/kg/week). Biomechanical axial compression tests were performed at the end of the study. Bone strength estimates using FEA were validated by ex-vivo mechanical compression testing experiments. After 18months of dosing, L-ODN demonstrated significant increases from baseline in integral vBMD (13.5%), cortical thickness (24.4%), total bone volume fraction BV/TV (13.5%), FEA-estimated peak force (26.6%) and peak stress (17.1%), respectively. Increases from baseline for L-ODN at 18 months were significantly higher than that for ALN in DXA-based aBMD (7.6%), cortical thickness (22.9%), integral vBMD (12.2%), total BV/TV (10.1%), FEA peak force (17.7%) and FEA peak stress (11.5%), respectively. These results demonstrate a superior efficacy of ODN treatment compared to ALN at the UD radii in ovariectomized NHPs.

  15. 基于BMD101的心率变异性分析系统设计%Design of Heart Rate Variability Analysis System Based on BMD101

    Institute of Scientific and Technical Information of China (English)

    嵇晓强; 赵春华; 宁春玉; 张亭亭; 谷佳音; 田峰

    2015-01-01

    Heart rate variability analysis plays an important role in clinical application. According to the great size,high power consumption and expensive of the existed heart rate variability analysis system,a new heart rate variability analy-sis system was designed based on the highly integrated ECG signal detection and processing chip BMD101 module. First of all,human ECG signal was collected and transformed into digital signal by the BMD101,and then it transmit-ted to computer though the serial port to the computer. In computer,we preprocessed ECG data and extracted RR in-terval data firstly, and then analyzed the data in time domain and frequency domain in order to obtain the parameters of heart rate variability. The experimental results indicate that the ECG signal collected by this system is accurate,sta-ble and less noise,and the HRV analysis results are accurate and reliable. Moreover,the system has obvious advantag-es of low power consumption, small volume and can achieve the basic function of heart rate variability analysis, so it can meet the needs of clinical portable heart rate variability analysis equipment.%心率变异性分析在临床应用上发挥着重要的作用.针对现有心率变异性分析系统体积庞大、功耗较高、价格昂贵等问题,设计了一种基于高集成度心电信号检测和处理片上设备BMD101模块的心率变异性分析系统.首先通过BMD101模块采集人体心电信号,并转化成数字信号,然后通过串口送给计算机处理.计算机首先对心电数据进行预处理,提取出RR间期数据,然后进行时域和频域分析,获得所需要的心率变异性主要参数.实际测试结果表明:本系统采集的心电信号准确、稳定、噪声少,时域频域分析结果准确、可靠,且系统功耗低、体积小,能够实现基本的心率变异性分析功能,可满足临床便携式心率变异性分析设备的需求.

  16. Disentangling volumetric and hydrational properties of proteins.

    Science.gov (United States)

    Voloshin, Vladimir P; Medvedev, Nikolai N; Smolin, Nikolai; Geiger, Alfons; Winter, Roland

    2015-02-05

    We used molecular dynamics simulations of a typical monomeric protein, SNase, in combination with Voronoi-Delaunay tessellation to study and analyze the temperature dependence of the apparent volume, Vapp, of the solute. We show that the void volume, VB, created in the boundary region between solute and solvent, determines the temperature dependence of Vapp to a major extent. The less pronounced but still significant temperature dependence of the molecular volume of the solute, VM, is essentially the result of the expansivity of its internal voids, as the van der Waals contribution to VM is practically independent of temperature. Results for polypeptides of different chemical nature feature a similar temperature behavior, suggesting that the boundary/hydration contribution seems to be a universal part of the temperature dependence of Vapp. The results presented here shine new light on the discussion surrounding the physical basis for understanding and decomposing the volumetric properties of proteins and biomolecules in general.

  17. All Photons Imaging Through Volumetric Scattering

    Science.gov (United States)

    Satat, Guy; Heshmat, Barmak; Raviv, Dan; Raskar, Ramesh

    2016-01-01

    Imaging through thick highly scattering media (sample thickness ≫ mean free path) can realize broad applications in biomedical and industrial imaging as well as remote sensing. Here we propose a computational “All Photons Imaging” (API) framework that utilizes time-resolved measurement for imaging through thick volumetric scattering by using both early arrived (non-scattered) and diffused photons. As opposed to other methods which aim to lock on specific photons (coherent, ballistic, acoustically modulated, etc.), this framework aims to use all of the optical signal. Compared to conventional early photon measurements for imaging through a 15 mm tissue phantom, our method shows a two fold improvement in spatial resolution (4db increase in Peak SNR). This all optical, calibration-free framework enables widefield imaging through thick turbid media, and opens new avenues in non-invasive testing, analysis, and diagnosis. PMID:27683065

  18. A Technique for Volumetric CSG Based on Morphology

    DEFF Research Database (Denmark)

    Bærentzen, Jakob Andreas; Christensen, Niels Jørgen

    2001-01-01

    In this paper, a new technique for volumetric CSG is presented. The technique requires the input volumes to correspond to solids which fulfill a voxelization suitability criterion. Assume the CSG operation is union. The volumetric union of two such volumes is defined in terms of the voxelization...

  19. Femur ultrasound (FemUS)-first clinical results on hip fracture discrimination and estimation of femoral BMD

    DEFF Research Database (Denmark)

    Barkmann, R; Dencks, S; Laugier, P

    2010-01-01

    A quantitative ultrasound (QUS) device for measurements at the proximal femur was developed and tested in vivo (Femur Ultrasound Scanner, FemUS). Hip fracture discrimination was as good as for DXA, and a high correlation with hip BMD was achieved. Our results show promise for enhanced QUS......-based assessment of osteoporosis. INTRODUCTION: Dual X-ray absorptiometry (DXA) at the femur is the best predictor of hip fractures, better than DXA measurements at other sites. Calcaneal quantitative ultrasound (QUS) can be used to estimate the general osteoporotic fracture risk, but no femoral QUS measurement...... has been introduced yet. We developed a QUS scanner for measurements at the femur (Femur Ultrasound Scanner, FemUS) and tested its in vivo performance. METHODS: Using the FemUS device, we obtained femoral QUS and DXA on 32 women with recent hip fractures and 30 controls. Fracture discrimination...

  20. Tibia and radius bone geometry and volumetric density in obese compared to non-obese adolescents☆

    Science.gov (United States)

    Leonard, Mary B.; Zemel, Babette S.; Wrotniak, Brian H.; Klieger, Sarah B.; Shults, Justine; Stallings, Virginia A.; Stettler, Nicolas

    2015-01-01

    Childhood obesity is associated with biologic and behavioral characteristics that may impact bone mineral density (BMD) and structure. The objective was to determine the association between obesity and bone outcomes, independent of sexual and skeletal maturity, muscle area and strength, physical activity, calcium intake, bio-markers of inflammation, and vitamin D status. Tibia and radius peripheral quantitative CT scans were obtained in 91 obese (BMI > 97th percentile) and 51 non-obese adolescents (BMI > 5th and <85th percentiles). Results were converted to sex- and race-specific Z-scores relative to age. Cortical structure, muscle area and muscle strength (by dynamometry) Z-scores were further adjusted for bone length. Obese participants had greater height Z-scores (p < 0.001), and advanced skeletal maturity (p < 0.0001), compared with non-obese participants. Tibia cortical section modulus and calf muscle area Z-scores were greater in obese participants (1.07 and 1.63, respectively, both p < 0.0001). Tibia and radius trabecular and cortical volumetric BMD did not differ significantly between groups. Calf muscle area and strength Z-scores, advanced skeletal maturity, and physical activity (by accelerometry) were positively associated with tibia cortical section modulus Z-scores (all p < 0.01). Adjustment for muscle area Z-score attenuated differences in tibia section modulus Z-scores between obese and non-obese participants from 1.07 to 0.28. After multivariate adjustment for greater calf muscle area and strength Z-scores, advanced maturity, and less moderate to vigorous physical activity, tibia section modulus Z-scores were 0.32 (95% CI −0.18, 0.43, p = 0.06) greater in obese, vs. non-obese participants. Radius cortical section modulus Z-scores were 0.45 greater (p = 0.08) in obese vs. non-obese participants; this difference was attenuated to 0.14 with adjustment for advanced maturity. These findings suggest that greater tibia cortical section modulus in obese

  1. Effect of odanacatib on bone turnover markers, bone density and geometry of the spine and hip of ovariectomized monkeys: a head-to-head comparison with alendronate.

    Science.gov (United States)

    Williams, Donald S; McCracken, Paul J; Purcell, Mona; Pickarski, Maureen; Mathers, Parker D; Savitz, Alan T; Szumiloski, John; Jayakar, Richa Y; Somayajula, Sangeetha; Krause, Stephen; Brown, Keenan; Winkelmann, Christopher T; Scott, Boyd B; Cook, Lynn; Motzel, Sherri L; Hargreaves, Richard; Evelhoch, Jeffrey L; Cabal, Antonio; Dardzinski, Bernard J; Hangartner, Thomas N; Duong, Le T

    2013-10-01

    Odanacatib (ODN) is a selective and reversible Cathepsin K (CatK) inhibitor currently being developed as a once weekly treatment for osteoporosis. Here, effects of ODN compared to alendronate (ALN) on bone turnover, DXA-based areal bone mineral density (aBMD), QCT-based volumetric BMD (vBMD) and geometric parameters were studied in ovariectomized (OVX) rhesus monkeys. Treatment was initiated 10 days after ovariectomy and continued for 20 months. The study consisted of four groups: L-ODN (2 mg/kg, daily p.o.), H-ODN (8/4 mg/kg daily p.o.), ALN (15 μg/kg, twice weekly, s.c.), and VEH (vehicle, daily, p.o.). L-ODN and ALN doses were selected to approximate the clinical exposures of the ODN 50-mg and ALN 70-mg once-weekly, respectively. L-ODN and ALN effectively reduced bone resorption markers uNTx and sCTx compared to VEH. There was no additional efficacy with these markers achieved with H-ODN. Conversely, ODN displayed inversely dose-dependent reduction of bone formation markers, sP1NP and sBSAP, and L-ODN reduced formation to a lesser degree than ALN. At month 18 post-OVX, L-ODN showed robust increases in lumbar spine aBMD (11.4%, pmonkeys in prevention mode. Taken together, the results from this study have demonstrated that administration of ODN at levels which approximate clinical exposure in OVX-monkeys had comparable efficacy to ALN in DXA-based aBMD and QCT-based vBMD. However, FN cortical mineral content clearly demonstrated superior efficacy of ODN versus ALN in this model of estrogen-deficient non-human primates.

  2. Soil volumetric water content measurements using TDR technique

    Directory of Open Access Journals (Sweden)

    S. Vincenzi

    1996-06-01

    Full Text Available A physical model to measure some hydrological and thermal parameters in soils will to be set up. The vertical profiles of: volumetric water content, matric potential and temperature will be monitored in different soils. The volumetric soil water content is measured by means of the Time Domain Reflectometry (TDR technique. The result of a test to determine experimentally the reproducibility of the volumetric water content measurements is reported together with the methodology and the results of the analysis of the TDR wave forms. The analysis is based on the calculation of the travel time of the TDR signal in the wave guide embedded in the soil.

  3. Iterative reconstruction of volumetric particle distribution

    Science.gov (United States)

    Wieneke, Bernhard

    2013-02-01

    For tracking the motion of illuminated particles in space and time several volumetric flow measurement techniques are available like 3D-particle tracking velocimetry (3D-PTV) recording images from typically three to four viewing directions. For higher seeding densities and the same experimental setup, tomographic PIV (Tomo-PIV) reconstructs voxel intensities using an iterative tomographic reconstruction algorithm (e.g. multiplicative algebraic reconstruction technique, MART) followed by cross-correlation of sub-volumes computing instantaneous 3D flow fields on a regular grid. A novel hybrid algorithm is proposed here that similar to MART iteratively reconstructs 3D-particle locations by comparing the recorded images with the projections calculated from the particle distribution in the volume. But like 3D-PTV, particles are represented by 3D-positions instead of voxel-based intensity blobs as in MART. Detailed knowledge of the optical transfer function and the particle image shape is mandatory, which may differ for different positions in the volume and for each camera. Using synthetic data it is shown that this method is capable of reconstructing densely seeded flows up to about 0.05 ppp with similar accuracy as Tomo-PIV. Finally the method is validated with experimental data.

  4. Characterizing volumetric deformation behavior of naturally occuring bituminous sand materials

    CSIR Research Space (South Africa)

    Anochie-Boateng, Joseph

    2009-05-01

    Full Text Available newly proposed hydrostatic compression test procedure. The test procedure applies field loading conditions of off-road construction and mining equipment to closely simulate the volumetric deformation and stiffness behaviour of oil sand materials. Based...

  5. Hyperspectral image classification based on volumetric texture and dimensionality reduction

    Science.gov (United States)

    Su, Hongjun; Sheng, Yehua; Du, Peijun; Chen, Chen; Liu, Kui

    2015-06-01

    A novel approach using volumetric texture and reduced-spectral features is presented for hyperspectral image classification. Using this approach, the volumetric textural features were extracted by volumetric gray-level co-occurrence matrices (VGLCM). The spectral features were extracted by minimum estimated abundance covariance (MEAC) and linear prediction (LP)-based band selection, and a semi-supervised k-means (SKM) clustering method with deleting the worst cluster (SKMd) bandclustering algorithms. Moreover, four feature combination schemes were designed for hyperspectral image classification by using spectral and textural features. It has been proven that the proposed method using VGLCM outperforms the gray-level co-occurrence matrices (GLCM) method, and the experimental results indicate that the combination of spectral information with volumetric textural features leads to an improved classification performance in hyperspectral imagery.

  6. Designing remote web-based mechanical-volumetric flow meter ...

    African Journals Online (AJOL)

    ... remote web-based mechanical-volumetric flow meter reading systems based on ... damage and also provides the ability to control and manage consumption. ... existing infrastructure of the telecommunications is used in data transmission.

  7. Morphological Atherosclerosis Calcification Distribution (MACD) Index is a Strong Predictor of Cardio-Vascular Death and Include Predictive Power of BMD

    DEFF Research Database (Denmark)

    Christiansen, Claus; Karsdal, Morten; Ganz, Melanie

    Aortic calcification is a major risk factor for cardiovascular disease (CVD) related deaths. We investigated the relation between mortality and aspects of number, size, morphology and distribution of calcified plaques in the lumbar aorta and BMD of postmenopausal women. 308 women aged 48 to 76 were...

  8. Effects of estrogen with micronized progesterone on cortical and trabecular bone mass and microstructure in recently postmenopausal women.

    Science.gov (United States)

    Farr, Joshua N; Khosla, Sundeep; Miyabara, Yuko; Miller, Virginia M; Kearns, Ann E

    2013-02-01

    In women, cortical bone mass decreases significantly at menopause. By contrast, loss of trabecular bone begins in the third decade and accelerates after menopause. The aim of the study was to investigate the effects of estrogen on cortical and trabecular bone. The Kronos Early Estrogen Prevention Study is a double-blind, randomized, placebo-controlled trial of menopausal hormone treatment (MHT) in women, enrolled within 6-36 months of their final menstrual period. The study was conducted at the Mayo Clinic, Rochester, Minnesota. Subjects were treated with placebo (n = 31), or .45 mg/d conjugated equine estrogens (n = 20), or transdermal 50 μg/d 17β-estradiol (n = 25) with pulsed micronized progesterone. Cortical and trabecular microarchitecture at the distal radius was assessed by high-resolution peripheral quantitative computed tomography. At the distal radius, cortical volumetric bone mineral density (vBMD) decreased, and cortical porosity increased in the placebo group; MHT prevented these changes. By contrast, MHT did not prevent decreases in trabecular microarchitecture at the radius. However, MHT prevented decreases in trabecular vBMD at the thoracic spine (assessed in a subset of subjects; n = 51). These results indicate that MHT prevents deterioration in radial cortical vBMD and porosity in recently menopausal women. The maintenance of cortical bone in response to estrogen likely has important clinical implications because cortical bone morphology plays an important role in bone strength. However, effects of MHT on trabecular bone at the radius differ from those at the thoracic spine. Underlying mechanisms for these site-specific effects of MHT on cortical vs trabecular bone require further investigation.

  9. The application of micro-CT in monitoring bone alterations in tail-suspended rats in vivo

    Science.gov (United States)

    Luan, Hui-Qin; Sun, Lian-Wen; Huang, Yun-Fei; Wang, Ying; McClean, Colin J.; Fan, Yu-Bo

    2014-06-01

    Osteopenia is a pathological process that affects human skeletal health not only on earth but also in long-time spaceflight. Micro-computed tomography (micro-CT) is a nondestructive method for assessing both bone quantity and bone quality. To investigate the characteristics of micro-CT on evaluating the microgravity-induced osteopenia (e.g. early detection time and the sensitive parameters), the bone loss process of tail-suspended rats was monitored by micro-CT in this study. 8-Week-old female Sprague Dawley rats were divided into two groups: tail suspension (TS) and control (CON). Volumetric bone mineral density (vBMD) and microstructure of the femur and tibia were evaluated in vivo by micro-CT at 0, 7, 14, 22 days. Biomechanical properties of the femur and tibia were determined by three-point bending test. The ash weight of bone was also investigated. The results showed that (1) bone loss in the proximal tibia appeared earlier than in the distal femur. (2) On day 7, the percent bone volume (BV/TV) of the tibia 15.44% decreased significantly, and the trabecular separation (Tb.Sp) 30.29% increased significantly in TS group, both of which were detected earlier than other parameters. (3) Biomechanical properties (e.g. femur, -22.4% maximum load and -23.75% Young’s modulus vs. CON) and ash weight of the femur and tibia decreased significantly in the TS group in comparison to CON group. (4) vBMD of the femur and tibia were clearly related to bone ash and dry weight (r = 0.75-0.87, p bone loss induced by tail suspension, moreover, trabecular vBMD and other parameters might be used to evaluate bone strength. Therefore, micro-CT is a reliable and sensitive method for predicting unloading-induced bone loss in small animals.

  10. Increasing the volumetric efficiency of Diesel engines by intake pipes

    Science.gov (United States)

    List, Hans

    1933-01-01

    Development of a method for calculating the volumetric efficiency of piston engines with intake pipes. Application of this method to the scavenging pumps of two-stroke-cycle engines with crankcase scavenging and to four-stroke-cycle engines. The utility of the method is demonstrated by volumetric-efficiency tests of the two-stroke-cycle engines with crankcase scavenging. Its practical application to the calculation of intake pipes is illustrated by example.

  11. Time course of 25(OHD3 vitamin D3 as well as PTH (parathyroid hormone during fracture healing of patients with normal and low bone mineral density (BMD

    Directory of Open Access Journals (Sweden)

    Wöfl Christoph

    2013-01-01

    Full Text Available Abstract Background Until now the exact biochemical processes during healing of metaphyseal fractures of healthy and osteoporotic bone remain unclear. Especially the physiological time courses of 25(OHD3 (Vitamin D as well as PTH (Parathyroid Hormone the most important modulators of calcium and bone homeostasis are not yet examined sufficiently. The purpose of this study was to focus on the time course of these parameters during fracture healing. Methods In the presented study, we analyse the time course of 25(OHD3 and PTH during fracture healing of low BMD level fractures versus normal BMD level fractures in a matched pair analysis. Between March 2007 and February 2009 30 patients older than 50 years of age who had suffered a metaphyseal fracture of the proximal humerus, the distal radius or the proximal femur were included in our study. Osteoporosis was verified by DEXA measuring. The time courses of 25(OHD3 and PTH were examined over an eight week period. Friedmann test, the Wilcoxon signed rank test and the Mann-Withney U test were used as post-hoc tests. A p-value ≤ 0.05 was considered significant. Results Serum levels of 25(OHD3 showed no differences in both groups. In the first phase of fracture healing PTH levels in the low BMD level group remained below those of the normal BMD group in absolute figures. Over all no significant differences between low BMD level bone and normal BMD level bone could be detected in our study. Conclusions The time course of 25(OHD3 and PTH during fracture healing of patients with normal and low bone mineral density were examined for the first time in humans in this setting and allowing molecular biological insights into fracture healing in metaphyseal bones on a molecural level. There were no significant differences between patients with normal and low BMD levels. Hence further studies will be necessary to obtain more detailed insight into fracture healing in order to provide reliable decision criteria for

  12. Serial volumetric registration of pulmonary CT studies

    Science.gov (United States)

    Silva, José Silvestre; Silva, Augusto; Sousa Santos, Beatriz

    2008-03-01

    Detailed morphological analysis of pulmonary structures and tissue, provided by modern CT scanners, is of utmost importance as in the case of oncological applications both for diagnosis, treatment, and follow-up. In this case, a patient may go through several tomographic studies throughout a period of time originating volumetric sets of image data that must be appropriately registered in order to track suspicious radiological findings. The structures or regions of interest may change their position or shape in CT exams acquired at different moments, due to postural, physiologic or pathologic changes, so, the exams should be registered before any follow-up information can be extracted. Postural mismatching throughout time is practically impossible to avoid being particularly evident when imaging is performed at the limiting spatial resolution. In this paper, we propose a method for intra-patient registration of pulmonary CT studies, to assist in the management of the oncological pathology. Our method takes advantage of prior segmentation work. In the first step, the pulmonary segmentation is performed where trachea and main bronchi are identified. Then, the registration method proceeds with a longitudinal alignment based on morphological features of the lungs, such as the position of the carina, the pulmonary areas, the centers of mass and the pulmonary trans-axial principal axis. The final step corresponds to the trans-axial registration of the corresponding pulmonary masked regions. This is accomplished by a pairwise sectional registration process driven by an iterative search of the affine transformation parameters leading to optimal similarity metrics. Results with several cases of intra-patient, intra-modality registration, up to 7 time points, show that this method provides accurate registration which is needed for quantitative tracking of lesions and the development of image fusion strategies that may effectively assist the follow-up process.

  13. Volumetric optoacoustic monitoring of endovenous laser treatments

    Science.gov (United States)

    Fehm, Thomas F.; Deán-Ben, Xosé L.; Schaur, Peter; Sroka, Ronald; Razansky, Daniel

    2016-03-01

    Chronic venous insufficiency (CVI) is one of the most common medical conditions with reported prevalence estimates as high as 30% in the adult population. Although conservative management with compression therapy may improve the symptoms associated with CVI, healing often demands invasive procedures. Besides established surgical methods like vein stripping or bypassing, endovenous laser therapy (ELT) emerged as a promising novel treatment option during the last 15 years offering multiple advantages such as less pain and faster recovery. Much of the treatment success hereby depends on monitoring of the treatment progression using clinical imaging modalities such as Doppler ultrasound. The latter however do not provide sufficient contrast, spatial resolution and three-dimensional imaging capacity which is necessary for accurate online lesion assessment during treatment. As a consequence, incidence of recanalization, lack of vessel occlusion and collateral damage remains highly variable among patients. In this study, we examined the capacity of volumetric optoacoustic tomography (VOT) for real-time monitoring of ELT using an ex-vivo ox foot model. ELT was performed on subcutaneous veins while optoacoustic signals were acquired and reconstructed in real-time and at a spatial resolution in the order of 200μm. VOT images showed spatio-temporal maps of the lesion progression, characteristics of the vessel wall, and position of the ablation fiber's tip during the pull back. It was also possible to correlate the images with the temperature elevation measured in the area adjacent to the ablation spot. We conclude that VOT is a promising tool for providing online feedback during endovenous laser therapy.

  14. Treatment planning for volumetric modulated arc therapy

    Energy Technology Data Exchange (ETDEWEB)

    Bedford, James L. [Joint Department of Physics, Institute of Cancer Research and The Royal Marsden NHS Foundation Trust, Downs Road, Sutton, Surrey SM2 5PT (United Kingdom)

    2009-11-15

    Purpose: Volumetric modulated arc therapy (VMAT) is a specific type of intensity-modulated radiation therapy (IMRT) in which the gantry speed, multileaf collimator (MLC) leaf position, and dose rate vary continuously during delivery. A treatment planning system for VMAT is presented. Methods: Arc control points are created uniformly throughout one or more arcs. An iterative least-squares algorithm is used to generate a fluence profile at every control point. The control points are then grouped and all of the control points in a given group are used to approximate the fluence profiles. A direct-aperture optimization is then used to improve the solution, taking into account the allowed range of leaf motion of the MLC. Dose is calculated using a fast convolution algorithm and the motion between control points is approximated by 100 interpolated dose calculation points. The method has been applied to five cases, consisting of lung, rectum, prostate and seminal vesicles, prostate and pelvic lymph nodes, and head and neck. The resulting plans have been compared with segmental (step-and-shoot) IMRT and delivered and verified on an Elekta Synergy to ensure practicality. Results: For the lung, prostate and seminal vesicles, and rectum cases, VMAT provides a plan of similar quality to segmental IMRT but with faster delivery by up to a factor of 4. For the prostate and pelvic nodes and head-and-neck cases, the critical structure doses are reduced with VMAT, both of these cases having a longer delivery time than IMRT. The plans in general verify successfully, although the agreement between planned and measured doses is not very close for the more complex cases, particularly the head-and-neck case. Conclusions: Depending upon the emphasis in the treatment planning, VMAT provides treatment plans which are higher in quality and/or faster to deliver than IMRT. The scheme described has been successfully introduced into clinical use.

  15. Visualization and volumetric structures from MR images of the brain

    Energy Technology Data Exchange (ETDEWEB)

    Parvin, B.; Johnston, W.; Robertson, D.

    1994-03-01

    Pinta is a system for segmentation and visualization of anatomical structures obtained from serial sections reconstructed from magnetic resonance imaging. The system approaches the segmentation problem by assigning each volumetric region to an anatomical structure. This is accomplished by satisfying constraints at the pixel level, slice level, and volumetric level. Each slice is represented by an attributed graph, where nodes correspond to regions and links correspond to the relations between regions. These regions are obtained by grouping pixels based on similarity and proximity. The slice level attributed graphs are then coerced to form a volumetric attributed graph, where volumetric consistency can be verified. The main novelty of our approach is in the use of the volumetric graph to ensure consistency from symbolic representations obtained from individual slices. In this fashion, the system allows errors to be made at the slice level, yet removes them when the volumetric consistency cannot be verified. Once the segmentation is complete, the 3D surfaces of the brain can be constructed and visualized.

  16. Soft bilateral filtering volumetric shadows using cube shadow maps

    Science.gov (United States)

    Ali, Hatam H.; Sunar, Mohd Shahrizal; Kolivand, Hoshang

    2017-01-01

    Volumetric shadows often increase the realism of rendered scenes in computer graphics. Typical volumetric shadows techniques do not provide a smooth transition effect in real-time with conservation on crispness of boundaries. This research presents a new technique for generating high quality volumetric shadows by sampling and interpolation. Contrary to conventional ray marching method, which requires extensive time, this proposed technique adopts downsampling in calculating ray marching. Furthermore, light scattering is computed in High Dynamic Range buffer to generate tone mapping. The bilateral interpolation is used along a view rays to smooth transition of volumetric shadows with respect to preserving-edges. In addition, this technique applied a cube shadow map to create multiple shadows. The contribution of this technique isreducing the number of sample points in evaluating light scattering and then introducing bilateral interpolation to improve volumetric shadows. This contribution is done by removing the inherent deficiencies significantly in shadow maps. This technique allows obtaining soft marvelous volumetric shadows, having a good performance and high quality, which show its potential for interactive applications. PMID:28632740

  17. Reassuring Russia On BMD

    Science.gov (United States)

    2016-02-16

    distribution unlimited. ii DISCLAIMER The views expressed in this academic research paper are those of the author and do not reflect the...5 Europe by 2018, and it is ultimately envisioned that the number of the more capable SM-3 Block II interceptors will be increased later in EPAA...expansion, which he believes the United States promised would not happen if the then Soviet Union acquiesced in the 1990 German reunification .25

  18. Alterations of bone density, microstructure, and strength of the distal radius in male patients with rheumatoid arthritis: a case-control study with HR-pQCT.

    Science.gov (United States)

    Zhu, Tracy Y; Griffith, James F; Qin, Ling; Hung, Vivian W; Fong, Tsz-Ning; Au, Sze-Ki; Li, Martin; Lam, Yvonne Yi-On; Wong, Chun-Kwok; Kwok, Anthony W; Leung, Ping-Chung; Li, Edmund K; Tam, Lai-Shan

    2014-09-01

    In this cross-sectional study, we investigated volumetric bone mineral density (vBMD), bone microstructure, and biomechanical competence of the distal radius in male patients with rheumatoid arthritis (RA). The study cohort comprised 50 male RA patients of average age of 61.1 years and 50 age-matched healthy males. Areal BMD (aBMD) of the hip, lumbar spine, and distal radius was measured by dual-energy X-ray absorptiometry. High-resolution peripheral quantitative computed tomography (HR-pQCT) of the distal radius provided measures of cortical and trabecular vBMD, microstructure, and biomechanical indices. aBMD of the hip but not the lumbar spine or ultradistal radius was significantly lower in RA patients than controls after adjustment for body weight. Total, cortical, and trabecular vBMD at the distal radius were, on average, -3.9% to -23.2% significantly lower in RA patients, and these differences were not affected by adjustment for body weight, testosterone level, or aBMD at the ultradistal radius. Trabecular microstructure indices were, on average, -8.1% (trabecular number) to 28.7% (trabecular network inhomogeneity) significantly inferior, whereas cortical pore volume and cortical porosity index were, on average, 80.3% and 63.9%, respectively, significantly higher in RA patients. RA patients also had significantly lower whole-bone stiffness, modulus, and failure load, with lower and more unevenly distributed cortical and trabecular stress. Density and microstructure indices significantly correlated with disease activity, severity, and levels of pro-inflammatory cytokines (interleukin [IL] 12p70, tumor necrosis factor, IL-6 and IL-1β). Ten RA patients had focal periosteal bone apposition most prominent at the ulnovolar aspect of the distal radius. These patients had shorter disease duration and significantly higher cortical porosity. In conclusion, HR-pQCT reveals significant alterations of bone density, microstructure, and strength of the distal radius in

  19. Improved volumetric imaging in tomosynthesis using combined multiaxial sweeps.

    Science.gov (United States)

    Gersh, Jacob A; Wiant, David B; Best, Ryan C M; Bennett, Marcus C; Munley, Michael T; King, June D; McKee, Mahta M; Baydush, Alan H

    2010-09-03

    This study explores the volumetric reconstruction fidelity attainable using tomosynthesis with a kV imaging system which has a unique ability to rotate isocentrically and with multiple degrees of mechanical freedom. More specifically, we seek to investigate volumetric reconstructions by combining multiple limited-angle rotational image acquisition sweeps. By comparing these reconstructed images with those of a CBCT reconstruction, we can gauge the volumetric fidelity of the reconstructions. In surgical situations, the described tomosynthesis-based system could provide high-quality volumetric imaging without requiring patient motion, even with rotational limitations present. Projections were acquired using the Digital Integrated Brachytherapy Unit, or IBU-D. A phantom was used which contained several spherical objects of varying contrast. Using image projections acquired during isocentric sweeps around the phantom, reconstructions were performed by filtered backprojection. For each image acquisition sweep configuration, a contrasting sphere is analyzed using two metrics and compared to a gold standard CBCT reconstruction. Since the intersection of a reconstructed sphere and an imaging plane is ideally a circle with an eccentricity of zero, the first metric presented compares the effective eccentricity of intersections of reconstructed volumes and imaging planes. As another metric of volumetric reconstruction fidelity, the volume of one of the contrasting spheres was determined using manual contouring. By comparing these manually delineated volumes with a CBCT reconstruction, we can gauge the volumetric fidelity of reconstructions. The configuration which yielded the highest overall volumetric reconstruction fidelity, as determined by effective eccentricities and volumetric contouring, consisted of two orthogonally-offset 60° L-arm sweeps and a single C-arm sweep which shared a pivot point with one the L-arm sweeps. When compared to a similar configuration that

  20. Aspects of volumetric efficiency measurement for reciprocating engines

    Directory of Open Access Journals (Sweden)

    Pešić Radivoje B.

    2013-01-01

    Full Text Available The volumetric efficiency significantly influences engine output. Both design and dimensions of an intake and exhaust system have large impact on volumetric efficiency. Experimental equipment for measuring of airflow through the engine, which is placed in the intake system, may affect the results of measurements and distort the real picture of the impact of individual structural factors. This paper deals with the problems of experimental determination of intake airflow using orifice plates and the influence of orifice plate diameter on the results of the measurements. The problems of airflow measurements through a multi-process Otto/Diesel engine were analyzed. An original method for determining volumetric efficiency was developed based on in-cylinder pressure measurement during motored operation, and appropriate calibration of the experimental procedure was performed. Good correlation between the results of application of the original method for determination of volumetric efficiency and the results of theoretical model used in research of influence of the intake pipe length on volumetric efficiency was determined. [Acknowledgments. The paper is the result of the research within the project TR 35041 financed by the Ministry of Science and Technological Development of the Republic of Serbia

  1. Calcium phosphate bone cement containing ABK and PLLA. Sustained release of ABK, the BMD of the femur in rats, and histological examination

    Energy Technology Data Exchange (ETDEWEB)

    Kusaka, T.; Tanaka, A.; Sasaki, S.; Takano, I.; Tahara, Y.; Ishii, Y. [Kyorin Univ., Tokyo (Japan). Dept. of Orhtopaedic Surgery

    2001-07-01

    Bone cement was prepared by mixing CPC95 (Mitsubishi Material Co., Ltd.), ABK, and PLLA at a ratio of 14 : 1 : 2. In vitro, Antibiotic sustained release tests were performed by the total amount exchange method. In animal experiments, the bone cement was infused into the right femur of 18-month-old female SD rats. After 1, 2, 4, or 6 months, the BMD was determined by DXA in the bilateral femoral bones. In addition, hard tissue specimens were prepared, and the state of bone formation was observed. The release of the antibiotic was 1.73 {mu}g/ml until 18 days after administration, maintaining a concentration over the MIC80 for MRSA. In the animal experiments, the BMD significantly increased after 2 - 4 months. In the hard tissue specimens, direct binding on the bone-cement interface and bone formation in the cement were observed after 1 month. (orig.)

  2. A high volume, high throughput volumetric sorption analyzer

    Science.gov (United States)

    Soo, Y. C.; Beckner, M.; Romanos, J.; Wexler, C.; Pfeifer, P.; Buckley, P.; Clement, J.

    2011-03-01

    In this talk we will present an overview of our new Hydrogen Test Fixture (HTF) constructed by the Midwest Research Institute for The Alliance for Collaborative Research in Alternative Fuel Technology to test activated carbon monoliths for hydrogen gas storage. The HTF is an automated, computer-controlled volumetric instrument for rapid screening and manipulation of monoliths under an inert atmosphere (to exclude degradation of carbon from exposure to oxygen). The HTF allows us to measure large quantity (up to 500 g) of sample in a 0.5 l test tank, making our results less sensitive to sample inhomogeneity. The HTF can measure isotherms at pressures ranging from 1 to 300 bar at room temperature. For comparison, other volumetric instruments such as Hiden Isochema's HTP-1 Volumetric Analyser can only measure carbon samples up to 150 mg at pressures up to 200 bar. Work supported by the US DOD Contract # N00164-08-C-GS37.

  3. Volumetric (3D) compressive sensing spectral domain optical coherence tomography.

    Science.gov (United States)

    Xu, Daguang; Huang, Yong; Kang, Jin U

    2014-11-01

    In this work, we proposed a novel three-dimensional compressive sensing (CS) approach for spectral domain optical coherence tomography (SD OCT) volumetric image acquisition and reconstruction. Instead of taking a spectral volume whose size is the same as that of the volumetric image, our method uses a sub set of the original spectral volume that is under-sampled in all three dimensions, which reduces the amount of spectral measurements to less than 20% of that required by the Shan-non/Nyquist theory. The 3D image is recovered from the under-sampled spectral data dimension-by-dimension using the proposed three-step CS reconstruction strategy. Experimental results show that our method can significantly reduce the sampling rate required for a volumetric SD OCT image while preserving the image quality.

  4. Multiple sparse volumetric priors for distributed EEG source reconstruction.

    Science.gov (United States)

    Strobbe, Gregor; van Mierlo, Pieter; De Vos, Maarten; Mijović, Bogdan; Hallez, Hans; Van Huffel, Sabine; López, José David; Vandenberghe, Stefaan

    2014-10-15

    We revisit the multiple sparse priors (MSP) algorithm implemented in the statistical parametric mapping software (SPM) for distributed EEG source reconstruction (Friston et al., 2008). In the present implementation, multiple cortical patches are introduced as source priors based on a dipole source space restricted to a cortical surface mesh. In this note, we present a technique to construct volumetric cortical regions to introduce as source priors by restricting the dipole source space to a segmented gray matter layer and using a region growing approach. This extension allows to reconstruct brain structures besides the cortical surface and facilitates the use of more realistic volumetric head models including more layers, such as cerebrospinal fluid (CSF), compared to the standard 3-layered scalp-skull-brain head models. We illustrated the technique with ERP data and anatomical MR images in 12 subjects. Based on the segmented gray matter for each of the subjects, cortical regions were created and introduced as source priors for MSP-inversion assuming two types of head models. The standard 3-layered scalp-skull-brain head models and extended 4-layered head models including CSF. We compared these models with the current implementation by assessing the free energy corresponding with each of the reconstructions using Bayesian model selection for group studies. Strong evidence was found in favor of the volumetric MSP approach compared to the MSP approach based on cortical patches for both types of head models. Overall, the strongest evidence was found in favor of the volumetric MSP reconstructions based on the extended head models including CSF. These results were verified by comparing the reconstructed activity. The use of volumetric cortical regions as source priors is a useful complement to the present implementation as it allows to introduce more complex head models and volumetric source priors in future studies.

  5. The beneficial effects of exercise on BMD are lost after cessation: a 5-year follow-up in older post-menopausal women.

    Science.gov (United States)

    Englund, U; Littbrand, H; Sondell, A; Bucht, G; Pettersson, U

    2009-06-01

    This study investigates whether the positive effects on bone mineral density (BMD, g/cm(2)) and neuromuscular function following a combined weight-bearing program are sustained in older women, a longer period after cessation of training. Thirty-four women (18 exercisers and 16 controls) aged 73-88 years, who completed a 12-month randomized-controlled trial, were invited to a 5-year follow-up assessment of BMD and neuromuscular function. Both groups sustained significant losses in BMD of the femoral neck, trochanter, and Ward's triangle during the follow-up period. Significant losses were also seen in all neuromuscular function tests. The inter-group change was, however, significant only for maximal walking speed where the exercise group had a significantly greater loss. In conclusion, this study suggests that gains in bone density and neuromuscular functions achieved by training are lost after cessation of training. Continuous high-intensity weight-loading physical activity is probably necessary to preserve bone density and neuromuscular function in older women.

  6. Volumetric measurements of a spatially growing dust acoustic wave

    Science.gov (United States)

    Williams, Jeremiah D.

    2012-11-01

    In this study, tomographic particle image velocimetry (tomo-PIV) techniques are used to make volumetric measurements of the dust acoustic wave (DAW) in a weakly coupled dusty plasma system in an argon, dc glow discharge plasma. These tomo-PIV measurements provide the first instantaneous volumetric measurement of a naturally occurring propagating DAW. These measurements reveal over the measured volume that the measured wave mode propagates in all three spatial dimensional and exhibits the same spatial growth rate and wavelength in each spatial direction.

  7. Volumetric measurements of a spatially growing dust acoustic wave

    Energy Technology Data Exchange (ETDEWEB)

    Williams, Jeremiah D. [Physics Department, Wittenberg University, Springfield, Ohio 45504 (United States)

    2012-11-15

    In this study, tomographic particle image velocimetry (tomo-PIV) techniques are used to make volumetric measurements of the dust acoustic wave (DAW) in a weakly coupled dusty plasma system in an argon, dc glow discharge plasma. These tomo-PIV measurements provide the first instantaneous volumetric measurement of a naturally occurring propagating DAW. These measurements reveal over the measured volume that the measured wave mode propagates in all three spatial dimensional and exhibits the same spatial growth rate and wavelength in each spatial direction.

  8. Volumetric Pricing of Agricultural Water Supplies: A Case Study

    Science.gov (United States)

    Griffin, Ronald C.; Perry, Gregory M.

    1985-07-01

    Models of water consumption by rice producers are conceptualized and then estimated using cross-sectional time series data obtained from 16 Texas canal operators for the years 1977-1982. Two alternative econometric models demonstrate that both volumetric and flat rate water charges are strongly and inversely related to agricultural water consumption. Nonprice conservation incentives accompanying flat rates are hypothesized to explain the negative correlation of flat rate charges and water consumption. Application of these results suggests that water supply organizations in the sample population converting to volumetric pricing will generally reduce water consumption.

  9. Trabecular Structure Quantified With the MRI-Based Virtual Bone Biopsy in Postmenopausal Women Contributes to Vertebral Deformity Burden Independent of Areal Vertebral BMD

    Science.gov (United States)

    Ladinsky, Glenn A; Vasilic, Branimir; Popescu, Andra M; Wald, Michael; Zemel, Babette S; Snyder, Peter J; Loh, Louise; Song, Hee Kwon; Saha, Punam K; Wright, Alexander C; Wehrli, Felix W

    2008-01-01

    In postmenopausal women with a wide range of vertebral deformities, MRI-based structural measures of topology and scale at the distal radius are shown to account for as much as 30% of vertebral deformity, independent of integral vertebral BMD. Introduction Trabecular bone architecture has been postulated to contribute to overall bone strength independent of vertebral BMD measured by DXA. However, there has thus far been only sparse in vivo evidence to support this hypothesis. Materials and Methods Postmenopausal women, 60–80 yr of age, were screened by DXA, and those with T-scores at either the hip or spine falling within the range of −2.5 ± 1.0 were studied with the MRI-based virtual bone biopsy, along with heel broadband ultrasound absorption and pQCT of the tibia. The data from 98 subjects meeting the enrollment criteria were subjected to μMRI at the distal tibia and radius, and measures of topology and scale of the trabecular bone network were computed. A spinal deformity index (SDI) was obtained from morphometric measurements in midline sagittal MR images of the thoracic and lumbar spine to evaluate associations between structure and deformity burden. Results A number of structural indices obtained at the distal radius were correlated with the SDI. Among these were the topological surface density (a measure of trabecular plates) and trabecular bone volume fraction, which were inversely correlated with SDI (p < 0.0001). Combinations of two structural parameters accounted for up to 30% of the variation in SDI (p < 0.0001) independent of spinal BMD, which was not significantly correlated. pQCT trabecular BMD was also weakly associated, whereas broadband ultrasound absorption was not. No significant association between SDI and structural indices were found at the tibia. Conclusions Structural measures at the distal radius obtained in vivo by μMRI explained a significant portion of the variation in total spinal deformity burden in postmenopausal women

  10. Are effects of MTHFR (C677T) genotype on BMD confined to women with low folate and riboflavin intake? Analysis of food records from the Danish osteoporosis prevention study.

    Science.gov (United States)

    Abrahamsen, Bo; Madsen, Jonna Skov; Tofteng, Charlotte Landbo; Stilgren, Lis; Bladbjerg, Else Marie; Kristensen, Søren Risom; Brixen, Kim; Mosekilde, Leif

    2005-03-01

    We have previously found BMD and fracture risk to be significantly associated with the MTHFR (C677T) polymorphism in healthy postmenopausal women in the first years after menopause. Since then, other cohort studies have suggested that sufficient intake of riboflavin and/or folate may have the potential to prevent development of low BMD in women with the TT genotype. This could to some extent explain why this polymorphism is associated with low BMD or fracture in some study populations and not in others. It would also indicate that fractures associated with the TT genotype could be preventable by vitamin B supplementation. We have, therefore, reviewed baseline food record data from our original study to determine if BMD and fracture associations with the MTHFR genotype depended on the intake of folate, riboflavin, or other members of the vitamin B complex, associated with homocysteine metabolism. We analyzed genotype, BMD, and dietary records from 1700 healthy postmenopausal women who participated in the DOPS study. For the assessment of fracture risk, we used longitudinal observations from 854 women in the control group who remained compliant with their initial allocation of no treatment. Riboflavin intake was significantly correlated with femoral neck (FN) BMD in women with the TT genotype (r = 0.24, P intake. At the FN, similar threshold effects were shown for folate, vitamin B12, and vitamin B6. Among these vitamin B complex members, stepwise regression analysis identified riboflavin as the only significant predictor of FN BMD in the TT genotype. In conclusion, we confirm reports that BMD in the MTHFR TT genotype is only significantly reduced in the lowest quartile of riboflavin, B12, B6, and folate intake, at least at the time of menopause. Vitamin B supplementation would only be expected to benefit BMD in about 2% of the population, i.e., those with the TT genotype and low vitamin B intake.

  11. Space-Time Transfinite Interpolation of Volumetric Material Properties.

    Science.gov (United States)

    Sanchez, Mathieu; Fryazinov, Oleg; Adzhiev, Valery; Comninos, Peter; Pasko, Alexander

    2015-02-01

    The paper presents a novel technique based on extension of a general mathematical method of transfinite interpolation to solve an actual problem in the context of a heterogeneous volume modelling area. It deals with time-dependent changes to the volumetric material properties (material density, colour, and others) as a transformation of the volumetric material distributions in space-time accompanying geometric shape transformations such as metamorphosis. The main idea is to represent the geometry of both objects by scalar fields with distance properties, to establish in a higher-dimensional space a time gap during which the geometric transformation takes place, and to use these scalar fields to apply the new space-time transfinite interpolation to volumetric material attributes within this time gap. The proposed solution is analytical in its nature, does not require heavy numerical computations and can be used in real-time applications. Applications of this technique also include texturing and displacement mapping of time-variant surfaces, and parametric design of volumetric microstructures.

  12. In Vivo Real Time Volumetric Synthetic Aperture Ultrasound Imaging

    DEFF Research Database (Denmark)

    Bouzari, Hamed; Rasmussen, Morten Fischer; Brandt, Andreas Hjelm;

    2015-01-01

    Synthetic aperture (SA) imaging can be used to achieve real-time volumetric ultrasound imaging using 2-D array transducers. The sensitivity of SA imaging is improved by maximizing the acoustic output, but one must consider the limitations of an ultrasound system, both technical and biological...

  13. Automatic segmentation of pulmonary segments from volumetric chest CT scans.

    NARCIS (Netherlands)

    Rikxoort, E.M. van; Hoop, B. de; Vorst, S. van de; Prokop, M.; Ginneken, B. van

    2009-01-01

    Automated extraction of pulmonary anatomy provides a foundation for computerized analysis of computed tomography (CT) scans of the chest. A completely automatic method is presented to segment the lungs, lobes and pulmonary segments from volumetric CT chest scans. The method starts with lung segmenta

  14. Volumetric T-spline Construction Using Boolean Operations

    Science.gov (United States)

    2013-07-01

    15213, USA 2 Institute for Computational Engineering and Sciences, The University of Texas at Austin, Austin, TX 78712, USA 3 Department of Civil and...and S. Yau. Volumetric harmonic map. Communications in Information and Systems, 3(3):191–202, 2003. 12. C.A.R. Guerra . Simultaneous untangling and

  15. Volumetric motion quantification by 3D tissue phase mapped CMR

    Directory of Open Access Journals (Sweden)

    Lutz Anja

    2012-10-01

    Full Text Available Abstract Background The objective of this study was the quantification of myocardial motion from 3D tissue phase mapped (TPM CMR. Recent work on myocardial motion quantification by TPM has been focussed on multi-slice 2D acquisitions thus excluding motion information from large regions of the left ventricle. Volumetric motion assessment appears an important next step towards the understanding of the volumetric myocardial motion and hence may further improve diagnosis and treatments in patients with myocardial motion abnormalities. Methods Volumetric motion quantification of the complete left ventricle was performed in 12 healthy volunteers and two patients applying a black-blood 3D TPM sequence. The resulting motion field was analysed regarding motion pattern differences between apical and basal locations as well as for asynchronous motion pattern between different myocardial segments in one or more slices. Motion quantification included velocity, torsion, rotation angle and strain derived parameters. Results All investigated motion quantification parameters could be calculated from the 3D-TPM data. Parameters quantifying hypokinetic or asynchronous motion demonstrated differences between motion impaired and healthy myocardium. Conclusions 3D-TPM enables the gapless volumetric quantification of motion abnormalities of the left ventricle, which can be applied in future application as additional information to provide a more detailed analysis of the left ventricular function.

  16. Video-rate volumetric optical coherence tomography-based microangiography

    Science.gov (United States)

    Baran, Utku; Wei, Wei; Xu, Jingjiang; Qi, Xiaoli; Davis, Wyatt O.; Wang, Ruikang K.

    2016-04-01

    Video-rate volumetric optical coherence tomography (vOCT) is relatively young in the field of OCT imaging but has great potential in biomedical applications. Due to the recent development of the MHz range swept laser sources, vOCT has started to gain attention in the community. Here, we report the first in vivo video-rate volumetric OCT-based microangiography (vOMAG) system by integrating an 18-kHz resonant microelectromechanical system (MEMS) mirror with a 1.6-MHz FDML swept source operating at ˜1.3 μm wavelength. Because the MEMS scanner can offer an effective B-frame rate of 36 kHz, we are able to engineer vOMAG with a video rate up to 25 Hz. This system was utilized for real-time volumetric in vivo visualization of cerebral microvasculature in mice. Moreover, we monitored the blood perfusion dynamics during stimulation within mouse ear in vivo. We also discussed this system's limitations. Prospective MEMS-enabled OCT probes with a real-time volumetric functional imaging capability can have a significant impact on endoscopic imaging and image-guided surgery applications.

  17. Analysis of Changing Swarm Rate using Volumetric Strain

    Science.gov (United States)

    Kumazawa, T.; Ogata, Y.; Kimura, K.; Maeda, K.; Kobayashi, A.

    2015-12-01

    Near the eastern coast of Izu peninsula is an active submarine volcanic region in Japan, where magma intrusions have been observed many times. The forecast of earthquake swarm activities and eruptions are serious concern particularly in nearby hot spring resort areas. It is well known that temporal durations of the swarm activities have been correlated with early volumetric strain changes at a certain observation station of about 20 km distance apart. Therefore the Earthquake Research Committee (2010) investigated some empirical statistical relations to predict sizes of the swarm activity. Here we looked at the background seismicity rate changes during these swarm periods using the non-stationary ETAS model (Kumazawa and Ogata, 2013, 2014), and have found the followings. The modified volumetric strain data, by removing the effect of earth tides, precipitation and coseismic jumps, have significantly higher cross-correlations to the estimated background rates of the ETAS model than to the swarm rate-changes. Specifically, the background seismicity rate synchronizes clearer to the strain change by the lags around a half day. These relations suggest an enhanced prediction of earthquakes in this region using volumetric strain measurements. Hence we propose an extended ETAS model where the background rate is modulated by the volumetric strain data. We have also found that the response function to the strain data can be well approximated by an exponential functions with the same decay rate, but that their intersects are inversely proportional to the distances between the volumetric strain-meter and the onset location of the swarm. Our numerical results by the same proposed model show consistent outcomes for the various major swarms in this region.

  18. The Intravertebral BMD Variation Measured by QCT%腰椎定量CT骨密度测量椎体内差异研究

    Institute of Scientific and Technical Information of China (English)

    李葆青; 孙金磊; 张祥; 王月卿; 王效丽; 程晓光; 陈祥述

    2011-01-01

    Purpose To improve the reproducibility and accuracy of spinal QCT by measuring bone mineral density (BMD) within different regions of interest (ROI) in the same vertebral body. Materials and Methods Two CT scanners were used to scan the lumbar vertebrae in 206 subjects (99 examples using 16-row Toshiba CT scanner and 107 examples using 64-row GE CT scanner). All CT scan data were transferred to the QCT pro workstation to measure the BMD of L1,L2 and L3 vertebral bodies. The region of interest (ROI) was placed in the upper,middle and lower parts of each vertebra to assess the variation of BMD. Results The average BMD values in the upper,middle and lower parts of L1-L3 was 116.75 (mg/cm3) ,126.37 (mg/cm3) and 123.77 (mg/cm3). This variation was statistically significant,but less than 8%. Conclusion There is intravertebral variation in BMD measured by QCT. The region of interest (ROI) should be placed in the middle of the vertebral body consistently to avoid measurement error.%目的 研究受检者椎体内不同感兴趣区(ROI)腰椎定量CT(QCT)骨密度测量结果的差异,以提高其测量的准确性和可重复性.资料与方法 对206例受检者进行腰椎检查(99例经GE 64排螺旋CT扫描,107例经东芝16排螺旋CT扫描),获取扫描数据,通过Mindways QCT PRO工作站进行分析处理,使用软件的3D测量模式进行测量,ROI分别放在每个椎体的上、中、下1/3部位,分别测量L1~L3椎体上、中、下3个部位松质骨骨密度(BMD).结果 L1~L3椎体上、中、下平均BMD分别为(116.75±47.73) mg/cm3、(126.37±47.63) mg/cm3和(123.77±52.67) mg/cm3,椎体内BMD差异有统计学意义(P<0.01),椎体内各部分骨密度相差<8%.结论 腰椎椎体内BMD存在区域性差异,QCT BMD测量时应选择相同的感兴趣区以减少误差,但在实际临床应用中影响较小.

  19. Tamizaje de deleciones en pacientes con distrofia muscular de Duchenne (DMD) o Becker-Kiener (BMD) mediante PCR multiplex en Costa Rica, 1998-2000

    OpenAIRE

    Sancho-Fernández, Vanessa M.; Saborio, Manuel; de Céspedes-Montealegre, Carlos; Azofeifa-Navas, Jorge

    2001-01-01

    Artículo científico -- Universidad de Costa Rica, Instituto de Investigaciones en Salud. 2001 Objetivo: Iniciar los estudios genético moleculares sobre las distrofinopatías en Costa Rica. Materiales y Métodos: Treinta y un pacientes varones, diagnosticados con distrofia muscular, que podrían ser distrofinopáticos fueron reevaluados clínicamente. Veintitrés mostraron un fenotipo de DMD y dos de BMD. Seis no mostraron síntomas definitivos de distrofinopatías. ADN de los pacientes fue analiza...

  20. Serum Levels of a Cathepsin-K Generated Periostin Fragment Predict Incident Low-Trauma Fractures in Postmenopausal Women Independently of BMD and FRAX.

    Science.gov (United States)

    Bonnet, Nicolas; Biver, Emmanuel; Chevalley, Thierry; Rizzoli, René; Garnero, Patrick; Ferrari, Serge L

    2017-08-02

    Periostin is a matricellular protein involved in bone formation and bone matrix organization, but it is also produced by other tissues. Its circulating levels have been weakly associated with bone microstructure and prevalent fractures, possibly because periostin measured by the current commercial assays does not specifically reflect bone metabolism. In this context, we developed a new ELISA for a periostin fragment resulting from cathepsin K digestion (K-Postn). We hypothesized that circulating K-Postn levels could be associated with bone fragility. A total of 695 women (age 65.0 ± 1.5 years), enrolled in the Geneva Retirees Cohort (GERICO), were prospectively evaluated over 4.7 ± 1.9 years for the occurrence of low-trauma fractures. At baseline, we measured serum periostin, K-Postn, and bone turnover markers (BTMs), distal radius and tibia microstructure by HR-pQCT, hip and lumbar spine aBMD by DXA, and estimated fracture probability using the Fracture Risk Assessment Tool (FRAX). Sixty-six women sustained a low-trauma clinical fracture during the follow-up. Total periostin was not associated with fractures (HR [95% CI] per SD: 1.19 [0.89 to 1.59], p = 0.24). In contrast, K-Postn was significantly higher in the fracture versus nonfracture group (57.5 ± 36.6 ng/mL versus 42.5 ± 23.4 ng/mL, p K-Postn remained significantly associated with fracture risk. The performance of the fracture prediction models was improved by adding K-Postn to aBMD or FRAX (Harrell C index for fracture: 0.70 for aBMD + K-Post versus 0.58 for aBMD alone, p = 0.001; 0.73 for FRAX + K-Postn versus 0.65 for FRAX alone, p = 0.005). Circulating K-Postn predicts incident fractures independently of BMD, BTMs, and FRAX in postmenopausal women. Hence measurement of a periostin fragment resulting from in vivo cathepsin K digestion may help to identify subjects at high risk of fracture. © 2017 American Society for Bone and Mineral Research. © 2017

  1. Association of 25-hydroxyvitamin D with areal and volumetric measures of bone mineral density and parathyroid hormone: impact of vitamin D-binding protein and its assays

    Science.gov (United States)

    Jemielita, T. O.; Leonard, M. B.; Baker, J.; Sayed, S.; Zemel, B. S.; Shults, J.; Herskovitz, R.

    2016-01-01

    Summary A comparison of the association of different forms of 25-hydroxyvitamin D [25(OH)D] with parathyroid hormone (PTH) and with areal and volumetric bone mineral density (BMD) demonstrated that bioavailable and free 25(OH)D do not provide a better index of vitamin D status in terms of bone health compared to total 25(OH)D. Introduction This study aims to compare measures of vitamin D-binding protein (DBP) using a monoclonal versus polyclonal ELISA and assess correlations of total versus estimated free and bioavailable 25(OH)D with BMD and PTH concentrations. Methods DXA and peripheral quantitative CT (pQCT) scans were obtained in 304 adults (158 black, 146 white), ages 21–80 years. Free and bioavailable 25(OH)D were calculated from total 25(OH)D, DBP, and albumin concentrations. Multivariable linear regression with standardized beta coefficients was used to evaluate associations of bone measures and PTH with total, free, and bioavailable 25(OH)D. Results Measures of DBP obtained using a monoclonal versus polyclonal ELISA were not correlated (rs=0.02, p=0.76). Free and bioavailable 25(OH)D based on the polyclonal assay were lower in black versus white participants (p<0.0001); this race difference was not evident using the monoclonal assay. Adjusted for age, sex, calcium intake, and race, all forms of 25(OH)D were negatively associated with PTH, but the absolute coefficient was greatest for total 25(OH)D (−0.34, p<0.001) versus free/bioavailable 25(OH)D (−0.18/−0.24 depending on DBP assay, p≤0.003). In analyses stratified on race, none of the measures of 25(OH)D were associated with BMD across DXA and pQCT sites. Conclusions The monoclonal versus polyclonal ELISA yielded highly discrepant measures of DBP, particularly among black individuals, likely related to established race differences in DBP polymorphisms. Contrary to prior studies, our findings indicate that using DBP to estimate bioavailable and free 25(OH)D does not provide a better index of

  2. Pulse sequence for dynamic volumetric imaging of hyperpolarized metabolic products

    Science.gov (United States)

    Cunningham, Charles H.; Chen, Albert P.; Lustig, Michael; Hargreaves, Brian A.; Lupo, Janine; Xu, Duan; Kurhanewicz, John; Hurd, Ralph E.; Pauly, John M.; Nelson, Sarah J.; Vigneron, Daniel B.

    2008-07-01

    Dynamic nuclear polarization and dissolution of a 13C-labeled substrate enables the dynamic imaging of cellular metabolism. Spectroscopic information is typically acquired, making the acquisition of dynamic volumetric data a challenge. To enable rapid volumetric imaging, a spectral-spatial excitation pulse was designed to excite a single line of the carbon spectrum. With only a single resonance present in the signal, an echo-planar readout trajectory could be used to resolve spatial information, giving full volume coverage of 32 × 32 × 16 voxels every 3.5 s. This high frame rate was used to measure the different lactate dynamics in different tissues in a normal rat model and a mouse model of prostate cancer.

  3. Nonrigid registration of volumetric images using ranked order statistics

    DEFF Research Database (Denmark)

    Tennakoon, Ruwan; Bab-Hadiashar, Alireza; Cao, Zhenwei

    2014-01-01

    Non-rigid image registration techniques using intensity based similarity measures are widely used in medical imaging applications. Due to high computational complexities of these techniques, particularly for volumetric images, finding appropriate registration methods to both reduce the computation...... burden and increase the registration accuracy has become an intensive area of research. In this paper we propose a fast and accurate non-rigid registration method for intra-modality volumetric images. Our approach exploits the information provided by an order statistics based segmentation method, to find...... the important regions for registration and use an appropriate sampling scheme to target those areas and reduce the registration computation time. A unique advantage of the proposed method is its ability to identify the point of diminishing returns and stop the registration process. Our experiments...

  4. Volumetric characterization of delamination fields via angle longitudinal wave ultrasound

    Science.gov (United States)

    Wertz, John; Wallentine, Sarah; Welter, John; Dierken, Josiah; Aldrin, John

    2017-02-01

    The volumetric characterization of delaminations necessarily precedes rigorous composite damage progression modeling. Yet, inspection of composite structures for subsurface damage remains largely focused on detection, resulting in a capability gap. In response to this need, angle longitudinal wave ultrasound was employed to characterize a composite surrogate containing a simulated three-dimensional delamination field with distinct regions of occluded features (shadow regions). Simple analytical models of the specimen were developed to guide subsequent experimentation through identification of optimal scanning parameters. The ensuing experiments provided visual evidence of the complete delamination field, including indications of features within the shadow regions. The results of this study demonstrate proof-of-principle for the use of angle longitudinal wave ultrasonic inspection for volumetric characterization of three-dimensional delamination fields. Furthermore, the techniques developed herein form the foundation of succeeding efforts to characterize impact delaminations within inhomogeneous laminar materials such as polymer matrix composites.

  5. Magnetic Resonance Image Segmentation and its Volumetric Measurement

    Directory of Open Access Journals (Sweden)

    Rahul R. Ambalkar

    2013-02-01

    Full Text Available Image processing techniques make it possible to extract meaningful information from medical images. Magnetic resonance (MR imaging has been widely applied in biological research and diagnostics because of its excellent soft tissue contrast, non-invasive character, high spatial resolution and easy slice selection at any orientation. The MRI-based brain volumetric is concerned with the analysis of volumes and shapes of the structural components of the human brain. It also provides a criterion, by which we recognize the presence of degenerative diseases and characterize their rates of progression to make the diagnosis and treatments as a easy task. In this paper we have proposed an automated method for volumetric measurement of Magnetic Resonance Imaging and used Self Organized Map (SOM clustering method for their segmentations. We have used the MRI data set of 61 slices of 256×256 pixels in DICOM standard format

  6. Two-dimensional random arrays for real time volumetric imaging

    DEFF Research Database (Denmark)

    Davidsen, Richard E.; Jensen, Jørgen Arendt; Smith, Stephen W.

    1994-01-01

    Two-dimensional arrays are necessary for a variety of ultrasonic imaging techniques, including elevation focusing, 2-D phase aberration correction, and real time volumetric imaging. In order to reduce system cost and complexity, sparse 2-D arrays have been considered with element geometries...... real time volumetric imaging system, which employs a wide transmit beam and receive mode parallel processing to increase image frame rate. Depth-of-field comparisons were made from simulated on-axis and off-axis beamplots at ranges from 30 to 160 mm for both coaxial and offset transmit and receive...... selected ad hoc, by algorithm, or by random process. Two random sparse array geometries and a sparse array with a Mills cross receive pattern were simulated and compared to a fully sampled aperture with the same overall dimensions. The sparse arrays were designed to the constraints of the Duke University...

  7. In Vivo Real Time Volumetric Synthetic Aperture Ultrasound Imaging

    DEFF Research Database (Denmark)

    Bouzari, Hamed; Rasmussen, Morten Fischer; Brandt, Andreas Hjelm

    2015-01-01

    . This paper investigates the in vivo applicability and sensitivity of volumetric SA imaging. Utilizing the transmit events to generate a set of virtual point sources, a frame rate of 25 Hz for a 90° x 90° field-of-view was achieved. Data were obtained using a 3.5 MHz 32 x 32 elements 2-D phased array......Synthetic aperture (SA) imaging can be used to achieve real-time volumetric ultrasound imaging using 2-D array transducers. The sensitivity of SA imaging is improved by maximizing the acoustic output, but one must consider the limitations of an ultrasound system, both technical and biological...... transducer connected to the experimental scanner (SARUS). Proper scaling is applied to the excitation signal such that intensity levels are in compliance with the U.S. Food and Drug Administration regulations for in vivo ultrasound imaging. The measured Mechanical Index and spatial-peak- temporal...

  8. COMPARISON OF VOLUMETRIC REGISTRATION ALGORITHMS FOR TENSOR-BASED MORPHOMETRY

    Science.gov (United States)

    Villalon, Julio; Joshi, Anand A.; Toga, Arthur W.; Thompson, Paul M.

    2015-01-01

    Nonlinear registration of brain MRI scans is often used to quantify morphological differences associated with disease or genetic factors. Recently, surface-guided fully 3D volumetric registrations have been developed that combine intensity-guided volume registrations with cortical surface constraints. In this paper, we compare one such algorithm to two popular high-dimensional volumetric registration methods: large-deformation viscous fluid registration, formulated in a Riemannian framework, and the diffeomorphic “Demons” algorithm. We performed an objective morphometric comparison, by using a large MRI dataset from 340 young adult twin subjects to examine 3D patterns of correlations in anatomical volumes. Surface-constrained volume registration gave greater effect sizes for detecting morphometric associations near the cortex, while the other two approaches gave greater effects sizes subcortically. These findings suggest novel ways to combine the advantages of multiple methods in the future. PMID:26925198

  9. Volumetric 3D display using a DLP projection engine

    Science.gov (United States)

    Geng, Jason

    2012-03-01

    In this article, we describe a volumetric 3D display system based on the high speed DLPTM (Digital Light Processing) projection engine. Existing two-dimensional (2D) flat screen displays often lead to ambiguity and confusion in high-dimensional data/graphics presentation due to lack of true depth cues. Even with the help of powerful 3D rendering software, three-dimensional (3D) objects displayed on a 2D flat screen may still fail to provide spatial relationship or depth information correctly and effectively. Essentially, 2D displays have to rely upon capability of human brain to piece together a 3D representation from 2D images. Despite the impressive mental capability of human visual system, its visual perception is not reliable if certain depth cues are missing. In contrast, volumetric 3D display technologies to be discussed in this article are capable of displaying 3D volumetric images in true 3D space. Each "voxel" on a 3D image (analogous to a pixel in 2D image) locates physically at the spatial position where it is supposed to be, and emits light from that position toward omni-directions to form a real 3D image in 3D space. Such a volumetric 3D display provides both physiological depth cues and psychological depth cues to human visual system to truthfully perceive 3D objects. It yields a realistic spatial representation of 3D objects and simplifies our understanding to the complexity of 3D objects and spatial relationship among them.

  10. Using surface heave to estimate reservoir volumetric strain

    Energy Technology Data Exchange (ETDEWEB)

    Nanayakkara, A.S.; Wong, R.C.K. [Calgary Univ., AB (Canada)

    2008-07-01

    This paper presented a newly developed numerical tool for estimating reservoir volumetric strain distribution using surface vertical displacements and solving an inverse problem. Waterflooding, steam injection, carbon dioxide sequestration and aquifer storage recovery are among the subsurface injection operations that are responsible for reservoir dilations which propagate to the surrounding formations and extend to the surface resulting in surface heaves. Global positioning systems and surface tiltmeters are often used to measure the characteristics of these surface heaves and to derive valuable information regarding reservoir deformation and flow characteristics. In this study, Tikhonov regularization techniques were adopted to solve the ill-posed inversion problem commonly found in standard inversion techniques such as Gaussian elimination and least squares methods. Reservoir permeability was then estimated by inverting the volumetric strain distribution. Results of the newly developed numerical tool were compared with results from fully-coupled finite element simulation of fluid injection problems. The reservoir volumetric strain distribution was successfully estimated along with an approximate value for reservoir permeability.

  11. Volumetric Light-field Encryption at the Microscopic Scale

    Science.gov (United States)

    Li, Haoyu; Guo, Changliang; Muniraj, Inbarasan; Schroeder, Bryce C.; Sheridan, John T.; Jia, Shu

    2017-01-01

    We report a light-field based method that allows the optical encryption of three-dimensional (3D) volumetric information at the microscopic scale in a single 2D light-field image. The system consists of a microlens array and an array of random phase/amplitude masks. The method utilizes a wave optics model to account for the dominant diffraction effect at this new scale, and the system point-spread function (PSF) serves as the key for encryption and decryption. We successfully developed and demonstrated a deconvolution algorithm to retrieve both spatially multiplexed discrete data and continuous volumetric data from 2D light-field images. Showing that the method is practical for data transmission and storage, we obtained a faithful reconstruction of the 3D volumetric information from a digital copy of the encrypted light-field image. The method represents a new level of optical encryption, paving the way for broad industrial and biomedical applications in processing and securing 3D data at the microscopic scale.

  12. Volumetric Light-field Encryption at the Microscopic Scale

    Science.gov (United States)

    Li, Haoyu; Guo, Changliang; Muniraj, Inbarasan; Schroeder, Bryce C.; Sheridan, John T.; Jia, Shu

    2017-01-01

    We report a light-field based method that allows the optical encryption of three-dimensional (3D) volumetric information at the microscopic scale in a single 2D light-field image. The system consists of a microlens array and an array of random phase/amplitude masks. The method utilizes a wave optics model to account for the dominant diffraction effect at this new scale, and the system point-spread function (PSF) serves as the key for encryption and decryption. We successfully developed and demonstrated a deconvolution algorithm to retrieve both spatially multiplexed discrete data and continuous volumetric data from 2D light-field images. Showing that the method is practical for data transmission and storage, we obtained a faithful reconstruction of the 3D volumetric information from a digital copy of the encrypted light-field image. The method represents a new level of optical encryption, paving the way for broad industrial and biomedical applications in processing and securing 3D data at the microscopic scale. PMID:28059149

  13. Volumetric Light-field Encryption at the Microscopic Scale

    CERN Document Server

    Li, Haoyu; Muniraj, Inbarasan; Schroeder, Bryce C; Sheridan, John T; Jia, Shu

    2016-01-01

    We report a light-field based method that allows the optical encryption of three-dimensional (3D) volumetric information at the microscopic scale in a single 2D light-field image. The system consists of a microlens array and an array of random phase/amplitude masks. The method utilizes a wave optics model to account for the dominant diffraction effect at this new scale, and the system point-spread function (PSF) serves as the key for encryption and decryption. We successfully developed and demonstrated a deconvolution algorithm to retrieve spatially multiplexed discrete and continuous volumetric data from 2D light-field images. Showing that the method is practical for data transmission and storage, we obtained a faithful reconstruction of the 3D volumetric information from a digital copy of the encrypted light-field image. The method represents a new level of optical encryption, paving the way for broad industrial and biomedical applications in processing and securing 3D data at the microscopic scale.

  14. Volumetric Light-field Encryption at the Microscopic Scale.

    Science.gov (United States)

    Li, Haoyu; Guo, Changliang; Muniraj, Inbarasan; Schroeder, Bryce C; Sheridan, John T; Jia, Shu

    2017-01-06

    We report a light-field based method that allows the optical encryption of three-dimensional (3D) volumetric information at the microscopic scale in a single 2D light-field image. The system consists of a microlens array and an array of random phase/amplitude masks. The method utilizes a wave optics model to account for the dominant diffraction effect at this new scale, and the system point-spread function (PSF) serves as the key for encryption and decryption. We successfully developed and demonstrated a deconvolution algorithm to retrieve both spatially multiplexed discrete data and continuous volumetric data from 2D light-field images. Showing that the method is practical for data transmission and storage, we obtained a faithful reconstruction of the 3D volumetric information from a digital copy of the encrypted light-field image. The method represents a new level of optical encryption, paving the way for broad industrial and biomedical applications in processing and securing 3D data at the microscopic scale.

  15. Meta-analysis of genome-wide scans for total body BMD in children and adults reveals allelic heterogeneity and age-specific effects at the WNT16 locus.

    Directory of Open Access Journals (Sweden)

    Carolina Medina-Gomez

    2012-07-01

    Full Text Available To identify genetic loci influencing bone accrual, we performed a genome-wide association scan for total-body bone mineral density (TB-BMD variation in 2,660 children of different ethnicities. We discovered variants in 7q31.31 associated with BMD measurements, with the lowest P = 4.1 × 10(-11 observed for rs917727 with minor allele frequency of 0.37. We sought replication for all SNPs located ± 500 kb from rs917727 in 11,052 additional individuals from five independent studies including children and adults, together with de novo genotyping of rs3801387 (in perfect linkage disequilibrium (LD with rs917727 in 1,014 mothers of children from the discovery cohort. The top signal mapping in the surroundings of WNT16 was replicated across studies with a meta-analysis P = 2.6 × 10(-31 and an effect size explaining between 0.6%-1.8% of TB-BMD variance. Conditional analyses on this signal revealed a secondary signal for total body BMD (P = 1.42 × 10(-10 for rs4609139 and mapping to C7orf58. We also examined the genomic region for association with skull BMD to test if the associations were independent of skeletal loading. We identified two signals influencing skull BMD variation, including rs917727 (P = 1.9 × 10(-16 and rs7801723 (P = 8.9 × 10(-28, also mapping to C7orf58 (r(2 = 0.50 with rs4609139. Wnt16 knockout (KO mice with reduced total body BMD and gene expression profiles in human bone biopsies support a role of C7orf58 and WNT16 on the BMD phenotypes observed at the human population level. In summary, we detected two independent signals influencing total body and skull BMD variation in children and adults, thus demonstrating the presence of allelic heterogeneity at the WNT16 locus. One of the skull BMD signals mapping to C7orf58 is mostly driven by children, suggesting temporal determination on peak bone mass acquisition. Our life-course approach postulates that these genetic effects influencing peak bone mass accrual may impact the risk of

  16. Inactivation of the Na-Cl co-transporter (NCC) gene is associated with high BMD through both renal and bone mechanisms: analysis of patients with Gitelman syndrome and Ncc null mice.

    Science.gov (United States)

    Nicolet-Barousse, Laurence; Blanchard, Anne; Roux, Christian; Pietri, Laurence; Bloch-Faure, May; Kolta, Sami; Chappard, Christine; Geoffroy, Valérie; Morieux, Caroline; Jeunemaitre, Xavier; Shull, Gary E; Meneton, Pierre; Paillard, Michel; Houillier, Pascal; De Vernejoul, Marie-Christine

    2005-05-01

    Chronic thiazide treatment is associated with high BMD. We report that patients and mice with null mutations in the thiazide-sensitive NaCl cotransporter (NCC) have higher renal tubular Ca reabsorption, higher BMD, and lower bone remodeling than controls, as well as abnormalities in Ca metabolism, mainly caused by Mg depletion. Chronic thiazide treatment decreases urinary Ca excretion (UVCa) and increases BMD. To understand the underlying mechanisms, Ca and bone metabolism were studied in two models of genetic inactivation of the thiazide-sensitive NaCl cotransporter (NCC): patients with Gitelman syndrome (GS) and Ncc knockout (Ncc(-/-)) mice. Ca metabolism was analyzed in GS patients and Ncc(-/-) mice under conditions of low dietary Ca. BMD was measured by DXA in patients and mice, and bone histomorphometry was analyzed in mice. GS patients had low plasma Mg. They exhibited reduced UVCa, but similar serum Ca and GFR as control subjects, suggesting increased renal Ca reabsorption. Blood PTH was lower despite lower serum ionized Ca, and Mg repletion almost corrected both relative hypoparathyroidism and low UVCa. BMD was significantly increased in GS patients at both lumbar (+7%) and femoral (+16%) sites, and osteocalcin was reduced. In Ncc(-/-) mice, serum Ca and GFR were unchanged, but UVCa was reduced and PTH was elevated; Mg repletion largely corrected both abnormalities. Trabecular and cortical BMD were higher than in Ncc(+/+) mice (+4% and +5%, respectively), and despite elevated PTH, were associated with higher cortical thickness and lower endosteal osteoclastic surface. Higher BMD is observed in GS patients and Ncc(-/-) mice. Relative hypoparathyroidism (human) and bone resistance to PTH (mice), mainly caused by Mg depletion, can explain the low bone remodeling and normal/low serum Ca despite increased renal Ca reabsorption.

  17. Bone loss over one year of training and competition in female cyclists

    Science.gov (United States)

    Sherk, Vanessa D; Barry, Daniel W; Villalon, Karen L; Hansen, Kent C; Wolfe, Pamela; Kohrt, Wendy M

    2014-01-01

    Objective To observe changes in hip, spine, and tibia bone characteristics in female cyclists over the course of 1 year of training. Design Prospective observational study Setting Laboratory Participants Female cyclists (n=14) aged 26-41 years with at least 1 year of competition history and intent to compete in 10 or more races in the coming year. Assessment of Risk Factors Women who train and compete in road cycling as their primary sport. Main Outcome Measures Total body fat-free and fat mass, and lumbar spine and proximal femur areal bone mineral density (aBMD) and bone mineral content (BMC) assessments by DXA. Volumetric BMD (vBMD) and BMC of the tibia were measured by pQCT at sites corresponding to 4%, 38%, 66%, and 96% of tibia length. Time points were baseline and after 12 months of training and competition. Results Weight and body composition did not change significantly over 12 months. Total hip aBMD and BMC decreased by −1.4±1.9% and −2.1±2.3% (p0.11). Conclusions Bone loss in female cyclists was site-specific and similar in magnitude to losses previously reported in male cyclists. Research is needed to understand the mechanisms for bone loss in cyclists. PMID:24326929

  18. Evaluation of teriparatide treatment in adults with osteogenesis imperfecta

    Science.gov (United States)

    Orwoll, Eric S.; Shapiro, Jay; Veith, Sandra; Wang, Ying; Lapidus, Jodi; Vanek, Chaim; Reeder, Jan L.; Keaveny, Tony M.; Lee, David C.; Mullins, Mary A.; Nagamani, Sandesh C.S.; Lee, Brendan

    2014-01-01

    Background. Adults with osteogenesis imperfecta (OI) have a high risk of fracture. Currently, few treatment options are available, and bone anabolic therapies have not been tested in clinical trials for OI treatment. Methods. 79 adults with OI were randomized to receive 20 μg recombinant human parathyroid hormone (teriparatide) or placebo for 18 months in a double-blind, placebo-controlled trial. The primary endpoint was the percent change in areal bone mineral density (aBMD) of the lumbar spine (LS), as determined by dual-energy X-ray absorptiometry. Secondary endpoints included percent change in bone remodeling markers and vertebral volumetric BMD (vBMD) by quantitative computed tomography, estimated vertebral strength by finite element analysis, and self-reported fractures. Results. Compared with the placebo group, the teriparatide group showed increased LS aBMD (6.1% ± 1.0% vs. 2.8% ± 1.0% change from baseline; P Imperfecta Foundation, Eli Lilly and Co., the National Center for Advancing Translational Science (NCATS) at the NIH (grant no. UL1RR024140), and the Baylor College of Medicine General Clinical Research Center (grant no. RR00188). PMID:24463451

  19. Volumetric CT-images improve testing of radiological image interpretation skills

    Energy Technology Data Exchange (ETDEWEB)

    Ravesloot, Cécile J., E-mail: C.J.Ravesloot@umcutrecht.nl [Radiology Department at University Medical Center Utrecht, Heidelberglaan 100, 3508 GA Utrecht, Room E01.132 (Netherlands); Schaaf, Marieke F. van der, E-mail: M.F.vanderSchaaf@uu.nl [Department of Pedagogical and Educational Sciences at Utrecht University, Heidelberglaan 1, 3584 CS Utrecht (Netherlands); Schaik, Jan P.J. van, E-mail: J.P.J.vanSchaik@umcutrecht.nl [Radiology Department at University Medical Center Utrecht, Heidelberglaan 100, 3508 GA Utrecht, Room E01.132 (Netherlands); Cate, Olle Th.J. ten, E-mail: T.J.tenCate@umcutrecht.nl [Center for Research and Development of Education at University Medical Center Utrecht, Heidelberglaan 100, 3508 GA Utrecht (Netherlands); Gijp, Anouk van der, E-mail: A.vanderGijp-2@umcutrecht.nl [Radiology Department at University Medical Center Utrecht, Heidelberglaan 100, 3508 GA Utrecht, Room E01.132 (Netherlands); Mol, Christian P., E-mail: C.Mol@umcutrecht.nl [Image Sciences Institute at University Medical Center Utrecht, Heidelberglaan 100, 3508 GA Utrecht (Netherlands); Vincken, Koen L., E-mail: K.Vincken@umcutrecht.nl [Image Sciences Institute at University Medical Center Utrecht, Heidelberglaan 100, 3508 GA Utrecht (Netherlands)

    2015-05-15

    Rationale and objectives: Current radiology practice increasingly involves interpretation of volumetric data sets. In contrast, most radiology tests still contain only 2D images. We introduced a new testing tool that allows for stack viewing of volumetric images in our undergraduate radiology program. We hypothesized that tests with volumetric CT-images enhance test quality, in comparison with traditional completely 2D image-based tests, because they might better reflect required skills for clinical practice. Materials and methods: Two groups of medical students (n = 139; n = 143), trained with 2D and volumetric CT-images, took a digital radiology test in two versions (A and B), each containing both 2D and volumetric CT-image questions. In a questionnaire, they were asked to comment on the representativeness for clinical practice, difficulty and user-friendliness of the test questions and testing program. Students’ test scores and reliabilities, measured with Cronbach's alpha, of 2D and volumetric CT-image tests were compared. Results: Estimated reliabilities (Cronbach's alphas) were higher for volumetric CT-image scores (version A: .51 and version B: .54), than for 2D CT-image scores (version A: .24 and version B: .37). Participants found volumetric CT-image tests more representative of clinical practice, and considered them to be less difficult than volumetric CT-image questions. However, in one version (A), volumetric CT-image scores (M 80.9, SD 14.8) were significantly lower than 2D CT-image scores (M 88.4, SD 10.4) (p < .001). The volumetric CT-image testing program was considered user-friendly. Conclusion: This study shows that volumetric image questions can be successfully integrated in students’ radiology testing. Results suggests that the inclusion of volumetric CT-images might improve the quality of radiology tests by positively impacting perceived representativeness for clinical practice and increasing reliability of the test.

  20. Personalized heterogeneous deformable model for fast volumetric registration.

    Science.gov (United States)

    Si, Weixin; Liao, Xiangyun; Wang, Qiong; Heng, Pheng Ann

    2017-02-20

    Biomechanical deformable volumetric registration can help improve safety of surgical interventions by ensuring the operations are extremely precise. However, this technique has been limited by the accuracy and the computational efficiency of patient-specific modeling. This study presents a tissue-tissue coupling strategy based on penalty method to model the heterogeneous behavior of deformable body, and estimate the personalized tissue-tissue coupling parameters in a data-driven way. Moreover, considering that the computational efficiency of biomechanical model is highly dependent on the mechanical resolution, a practical coarse-to-fine scheme is proposed to increase runtime efficiency. Particularly, a detail enrichment database is established in an offline fashion to represent the mapping relationship between the deformation results of high-resolution hexahedral mesh extracted from the raw medical data and a newly constructed low-resolution hexahedral mesh. At runtime, the mechanical behavior of human organ under interactions is simulated with this low-resolution hexahedral mesh, then the microstructures are synthesized in virtue of the detail enrichment database. The proposed method is validated by volumetric registration in an abdominal phantom compression experiments. Our personalized heterogeneous deformable model can well describe the coupling effects between different tissues of the phantom. Compared with high-resolution heterogeneous deformable model, the low-resolution deformable model with our detail enrichment database can achieve 9.4× faster, and the average target registration error is 3.42 mm, which demonstrates that the proposed method shows better volumetric registration performance than state-of-the-art. Our framework can well balance the precision and efficiency, and has great potential to be adopted in the practical augmented reality image-guided robotic systems.

  1. Volumetric measurements of pulmonary nodules: variability in automated analysis tools

    Science.gov (United States)

    Juluru, Krishna; Kim, Woojin; Boonn, William; King, Tara; Siddiqui, Khan; Siegel, Eliot

    2007-03-01

    Over the past decade, several computerized tools have been developed for detection of lung nodules and for providing volumetric analysis. Incidentally detected lung nodules have traditionally been followed over time by measurements of their axial dimensions on CT scans to ensure stability or document progression. A recently published article by the Fleischner Society offers guidelines on the management of incidentally detected nodules based on size criteria. For this reason, differences in measurements obtained by automated tools from various vendors may have significant implications on management, yet the degree of variability in these measurements is not well understood. The goal of this study is to quantify the differences in nodule maximum diameter and volume among different automated analysis software. Using a dataset of lung scans obtained with both "ultra-low" and conventional doses, we identified a subset of nodules in each of five size-based categories. Using automated analysis tools provided by three different vendors, we obtained size and volumetric measurements on these nodules, and compared these data using descriptive as well as ANOVA and t-test analysis. Results showed significant differences in nodule maximum diameter measurements among the various automated lung nodule analysis tools but no significant differences in nodule volume measurements. These data suggest that when using automated commercial software, volume measurements may be a more reliable marker of tumor progression than maximum diameter. The data also suggest that volumetric nodule measurements may be relatively reproducible among various commercial workstations, in contrast to the variability documented when performing human mark-ups, as is seen in the LIDC (lung imaging database consortium) study.

  2. In healthy elderly postmenopausal women variations in BMD and BMC at various skeletal sites are associated with differences in weight and lean body mass rather than by variations in habitual physical activity, strength or VO2max.

    Science.gov (United States)

    Schöffl, I; Kemmler, W; Kladny, B; Vonstengel, S; Kalender, W A; Engelke, K

    2008-01-01

    The objective of this study was an integrated cross-sectional investigation for answering the question whether differences in bone mineral density in elderly postmenopausal women are associated with differences in habitual physical activity and unspecific exercise levels. Two hundred and ninety nine elderly women (69-/+3 years), without diseases or medication affecting bone metabolism were investigated. The influence of weight, body composition and physical activity on BMD was measured at multiple sites using different techniques (DXA, QCT, and QUS). Physical activity and exercise level were assessed by questionnaire, maximum strength of the legs and aerobic capacity. Variations in physical activity or habitual exercise had no effect on bone. The only significant univariate relation between strength/VO(2)max and BMD/BMC that remained after adjusting for confounding variables was between arm BMD (DXA) and hand-grip strength. The most important variable for explaining BMD was weight and for cortical BMC of the femur (QCT) lean body mass. Weight and lean body mass emerge as predominant predictors of BMD in normal elderly women, whereas the isolated effect of habitual physical activity, unspecific exercise participation, and muscle strength on bone parameters is negligible. Thus, an increase in the amount of habitual physical activity will probably have no beneficial impact on bone.

  3. Volumetric hemispheric ratio as a useful tool in personality psychology.

    Science.gov (United States)

    Montag, Christian; Schoene-Bake, Jan-Christoph; Wagner, Jan; Reuter, Martin; Markett, Sebastian; Weber, Bernd; Quesada, Carlos M

    2013-02-01

    The present study investigates the link between volumetric hemispheric ratios (VHRs) and personality measures in N=267 healthy participants using Eysenck's Personality Inventory-Revised (EPQ-R) and the BIS/BAS scales. A robust association between extraversion and VHRs was observed for gray matter in males but not females. Higher gray matter volume in the left than in the right hemisphere was associated with higher extraversion in males. The results are discussed in the context of positive emotionality and laterality of the human brain.

  4. AN ATTRIBUTION OF CAVITATION RESONANCE: VOLUMETRIC OSCILLATIONS OF CLOUD

    Institute of Scientific and Technical Information of China (English)

    ZUO Zhi-gang; LI Sheng-cai; LIU Shu-hong; LI Shuang; CHEN Hui

    2009-01-01

    In order to further verify the proposed theory of cavitation resonance, as well as to proceed the investigations into microscopic level, a series of studies are being carried out on the Warwick venturi. The analysis of the oscillation characteristics of the cavitation resonance has conclusively verified the macro-mechanism proposed through previous studies on other cavitating flows by the authors. The initial observations using high-speed photographic approach have revealed a new attribution of cavitation resonance. That is, the volumetric oscillation of cavitation cloud is associated with the cavitation resonance, which is a collective behaviour of the bubbles in the cloud.

  5. Synthesis of Volumetric Ring Antenna Array for Terrestrial Coverage Pattern

    Directory of Open Access Journals (Sweden)

    Alberto Reyna

    2014-01-01

    Full Text Available This paper presents a synthesis of a volumetric ring antenna array for a terrestrial coverage pattern. This synthesis regards the spacing among the rings on the planes X-Y, the positions of the rings on the plane X-Z, and uniform and concentric excitations. The optimization is carried out by implementing the particle swarm optimization. The synthesis is compared with previous designs by resulting with proper performance of this geometry to provide an accurate coverage to be applied in satellite applications with a maximum reduction of the antenna hardware as well as the side lobe level reduction.

  6. Synthesis of Volumetric Ring Antenna Array for Terrestrial Coverage Pattern

    Science.gov (United States)

    Reyna, Alberto; Panduro, Marco A.; Del Rio Bocio, Carlos

    2014-01-01

    This paper presents a synthesis of a volumetric ring antenna array for a terrestrial coverage pattern. This synthesis regards the spacing among the rings on the planes X-Y, the positions of the rings on the plane X-Z, and uniform and concentric excitations. The optimization is carried out by implementing the particle swarm optimization. The synthesis is compared with previous designs by resulting with proper performance of this geometry to provide an accurate coverage to be applied in satellite applications with a maximum reduction of the antenna hardware as well as the side lobe level reduction. PMID:24701150

  7. Estimation of volumetric breast density for breast cancer risk prediction

    Science.gov (United States)

    Pawluczyk, Olga; Yaffe, Martin J.; Boyd, Norman F.; Jong, Roberta A.

    2000-04-01

    Mammographic density (MD) has been shown to be a strong risk predictor for breast cancer. Compared to subjective assessment by a radiologist, computer-aided analysis of digitized mammograms provides a quantitative and more reproducible method for assessing breast density. However, the current methods of estimating breast density based on the area of bright signal in a mammogram do not reflect the true, volumetric quantity of dense tissue in the breast. A computerized method to estimate the amount of radiographically dense tissue in the overall volume of the breast has been developed to provide an automatic, user-independent tool for breast cancer risk assessment. The procedure for volumetric density estimation consists of first correcting the image for inhomogeneity, then performing a volume density calculation. First, optical sensitometry is used to convert all images to the logarithm of relative exposure (LRE), in order to simplify the image correction operations. The field non-uniformity correction, which takes into account heel effect, inverse square law, path obliquity and intrinsic field and grid non- uniformity is obtained by imaging a spherical section PMMA phantom. The processed LRE image of the phantom is then used as a correction offset for actual mammograms. From information about the thickness and placement of the breast, as well as the parameters of a breast-like calibration step wedge placed in the mammogram, MD of the breast is calculated. Post processing and a simple calibration phantom enable user- independent, reliable and repeatable volumetric estimation of density in breast-equivalent phantoms. Initial results obtained on known density phantoms show the estimation to vary less than 5% in MD from the actual value. This can be compared to estimated mammographic density differences of 30% between the true and non-corrected values. Since a more simplistic breast density measurement based on the projected area has been shown to be a strong indicator

  8. Volumetric 3D Display System with Static Screen

    Science.gov (United States)

    Geng, Jason

    2011-01-01

    Current display technology has relied on flat, 2D screens that cannot truly convey the third dimension of visual information: depth. In contrast to conventional visualization that is primarily based on 2D flat screens, the volumetric 3D display possesses a true 3D display volume, and places physically each 3D voxel in displayed 3D images at the true 3D (x,y,z) spatial position. Each voxel, analogous to a pixel in a 2D image, emits light from that position to form a real 3D image in the eyes of the viewers. Such true volumetric 3D display technology provides both physiological (accommodation, convergence, binocular disparity, and motion parallax) and psychological (image size, linear perspective, shading, brightness, etc.) depth cues to human visual systems to help in the perception of 3D objects. In a volumetric 3D display, viewers can watch the displayed 3D images from a completely 360 view without using any special eyewear. The volumetric 3D display techniques may lead to a quantum leap in information display technology and can dramatically change the ways humans interact with computers, which can lead to significant improvements in the efficiency of learning and knowledge management processes. Within a block of glass, a large amount of tiny dots of voxels are created by using a recently available machining technique called laser subsurface engraving (LSE). The LSE is able to produce tiny physical crack points (as small as 0.05 mm in diameter) at any (x,y,z) location within the cube of transparent material. The crack dots, when illuminated by a light source, scatter the light around and form visible voxels within the 3D volume. The locations of these tiny voxels are strategically determined such that each can be illuminated by a light ray from a high-resolution digital mirror device (DMD) light engine. The distribution of these voxels occupies the full display volume within the static 3D glass screen. This design eliminates any moving screen seen in previous

  9. DXA测量BMD与超声测量SOS的比较%Comparison between SOS of quantitative ultrasound and BMD meas ured by DXA in diagnostic value of osteoporosis

    Institute of Scientific and Technical Information of China (English)

    安珍; 杨定焯; 王文志; 张祖君; 姜光瑶

    2001-01-01

    目的 本文通过对同一个人的跟骨超声声速(SOS)测量与双能X线吸收法测量腰2- 4,股骨近端骨密度(BMD)的临床对比来评价超声骨密度仪测量跟骨的SOS对诊断骨质疏松症 的敏感性和与DXA测量BMD的相关性。方法 对523名8~87岁健康人群同时采用DXA测量L2-4,股骨近端(N eck,Ward三角,Troch)BMD和超声骨密度仪测量左跟骨SOS值并进行相关分析。对1006名3~8 7岁健康人群测量左右跟骨的SOS值。结果 SOS与DXA测量BMD的骨峰值(PBM)均出现在20~39岁,SOS的PBM男性 为(1542.83±27.44)m/s,女性为(1531.02±29.96)m/s。40岁以后随着年龄的增加,二 者均逐渐下降。健康成人中BMD与SOS的相关系数为0.3~0.6,骨质疏松患者BMD与SOS的相 关系数(r=0.16~0.39)较健康人(r=0.33~0.61)低。左右足跟SOS无显著差异 ,DXA的BMD与SOS诊断骨质疏松症(OP)的符合率为60%。结论 DXA测量BMD与超声SOS为中等相关。建议在单独使用超声骨密度仪测 量SOS来诊断OP时,应当参照临床症状和X线的检查全面考虑,以免造成漏诊或误诊。%Dual energy x-ray absorptiometry(DXA) is a method o f measur ing the material properties of bone, that is, bone mineral density(BMD), whereas the quantitative ultrasound(QUS) is a method of assessing the mechanical proper ties of bone by the reflection and attenuation of ultrasound. We evaluated the s ensitivity of ultrasound in measuring bone mass by comparing with dual energy x -ray absorptiometry. BMD at lumbar spine and proximal part of the femur was mea sured by DXA and SOS at calcaneus by QUS in 892 subjects of 3 to 87 years in Chengdu. The results showed that SOS peaked at the age of 20 and declined with aging. The peak SOS was (1542.83±27.44)m/s in males and (1531.02±28.96)m/s in females. The correlation coefficients between SOS and BMD were 0.12~0.21 in children and 0.3~0.6 in adults, respectively. The homogeneity rate of the

  10. 补肾健脾益气法对酒精性骨质疏松大鼠骨密度(BMD)、骨矿含量(BMC)影响的研究%Influence of the Method of Tonifying Kidney, Strengthening Spleen and Supporting Qi on Bone Mineral Density(BMD) and Bone Mineral Content(BMC)with Alcoholic Osteoporosis(AOP) in Rats

    Institute of Scientific and Technical Information of China (English)

    任树军; 邢国利; 姜益常; 葛明富; 毕旭伟

    2013-01-01

    Objective: To observe the influence of the method of tonifying kidney, strengthening spleen and supporting Qi on bone mineral density (BMD) and bone mineral content (BMD) with Alcoholic osteoporosis (AOP) in rats, and to investigate the mechanism of herbs for strengthening kidney and spleen on AOP. Method: 40 adult male SD rats of pathogen - free were randomly divided into four groups on average: model group, western medicine control group, Chinese medicine intervention group and normal control group. The animal model of AOP was induced by irrigation stomach with the Red Start ( Hongxing) Erguotou ( rats in normal control group received saline) , simultaneously, saline, Calcium Carbonate alpha D3, JianGuLing capsule and saline were given to four groups, respectively. Sixteen weeks later, BMD and BMC of thighbone were measured by dual energy X - ray absorptiometry. Results: BMD and BMC in model group were remarkablely decreased compared with normal control group, the difference was significant(P <0. 01) , which suggested that rats receiving high concentrations of liguor for 16 weeks really resulted in decrease of BMD and BMC. Furthermore, BMD and BMC in Chinese medicine intervention group(P < 0.01) and western medicine control group (P < 0.05) were remarkablely increased compared with model group. In addition, BMD and BMC in Chinese medicine intervention group were higher than those in Western medicine control group(P < 0.05) , suggesting that Chinese medicine intervention group was superior to western medicine control group. Conclusion: Rats with AOP possess bone metabolism disorder, bone formation decreasing, bone loss reducing and finally induced osteoporosis. The method of tonifying kidney, strengthening spleen and supporting Qi can enhance BMD and BMC, and inhibit loss of bone mineral in rats with AOP, thereby it can effectively improve bone metabolism of rats with AOP.%目的:观察补肾健脾益气法对酒精性骨质疏松(AOP)大鼠骨密度影

  11. [Relationship of pharmacokinetics, changes of bone turnover markers and BMD/fractures efficacy during treatment with anabolic agents;Teriparatide daily and once weekly subcutaneous injections.

    Science.gov (United States)

    Miyauchi, Akimitsu

    Teriparatide(recombinant human PTH1-34, 20 μg daily subcutaneous injection)has been approved for osteoporosis patients at high risk of fracture in many countries including Japan. Teriparatide daily injection therapy has been reported to increase BMD, improve microarchitecture of bone, and reduce the risk of new vertebral fractures and that of non-vertebral fractures. Pharmakokinetic(PK)study after a single Teriparatide injection of the daily dose in healthy Japanese postmenopausal women(n=18)revealed very rapid achievement of peak blood level(median of tmax=0.25 hr)followed by fast disappearance from the blood(mean t1/2=0.708 hr, n=17). Consistent with these PK characteristics, a rapid increase in bone formation marker and later increase in bone resorption marker has previously been observed, which was described as a bone anabolic window. More recently, once weekly subcutaneous injection of teriparatide acetate(56.5 μg)has been reported to reduce the risk of new vertebral fractures compared with placebo and has been approved in Japan. PK study after injection of the higher weekly dose in healthy Japanese postmenopausal women(n=10)revealed a relatively slow achievement of the peak blood level(mean tmax=0.875 hr)compared to daily injections, followed by relatively slow disappearance from the blood(mean t1/2=1.295 hr). Consistent with these PK characteristics, an initial(<24 hr)transient decrease of bone formation markers(serum osteocalcin and P1NP)and transient increase of bone resorption markers(serum NTX and urinary CTX)were observed. However, afterword, the bone formation and resorption markers were increased and decreased, respectively, for longer than 1 week from the baseline levels. The relationship of pharmacokinetics, changes of bone turnover markers and BMD/fractures efficacy during daily versus weekly teriparatide treatment needs to be clarified.

  12. Floating volumetric image formation using a dihedral corner reflector array device.

    Science.gov (United States)

    Miyazaki, Daisuke; Hirano, Noboru; Maeda, Yuki; Yamamoto, Siori; Mukai, Takaaki; Maekawa, Satoshi

    2013-01-01

    A volumetric display system using an optical imaging device consisting of numerous dihedral corner reflectors placed perpendicular to the surface of a metal plate is proposed. Image formation by the dihedral corner reflector array (DCRA) is free from distortion and focal length. In the proposed volumetric display system, a two-dimensional real image is moved by a mirror scanner to scan a three-dimensional (3D) space. Cross-sectional images of a 3D object are displayed in accordance with the position of the image plane. A volumetric image is observed as a stack of the cross-sectional images. The use of the DCRA brings compact system configuration and volumetric real image generation with very low distortion. An experimental volumetric display system including a DCRA, a galvanometer mirror, and a digital micro-mirror device was constructed to verify the proposed method. A volumetric image consisting of 1024×768×400 voxels was formed by the experimental system.

  13. Volumetric display containing multiple two-dimensional color motion pictures

    Science.gov (United States)

    Hirayama, R.; Shiraki, A.; Nakayama, H.; Kakue, T.; Shimobaba, T.; Ito, T.

    2014-06-01

    We have developed an algorithm which can record multiple two-dimensional (2-D) gradated projection patterns in a single three-dimensional (3-D) object. Each recorded pattern has the individual projected direction and can only be seen from the direction. The proposed algorithm has two important features: the number of recorded patterns is theoretically infinite and no meaningful pattern can be seen outside of the projected directions. In this paper, we expanded the algorithm to record multiple 2-D projection patterns in color. There are two popular ways of color mixing: additive one and subtractive one. Additive color mixing used to mix light is based on RGB colors and subtractive color mixing used to mix inks is based on CMY colors. We made two coloring methods based on the additive mixing and subtractive mixing. We performed numerical simulations of the coloring methods, and confirmed their effectiveness. We also fabricated two types of volumetric display and applied the proposed algorithm to them. One is a cubic displays constructed by light-emitting diodes (LEDs) in 8×8×8 array. Lighting patterns of LEDs are controlled by a microcomputer board. The other one is made of 7×7 array of threads. Each thread is illuminated by a projector connected with PC. As a result of the implementation, we succeeded in recording multiple 2-D color motion pictures in the volumetric displays. Our algorithm can be applied to digital signage, media art and so forth.

  14. Volumetric three-dimensional display system with rasterization hardware

    Science.gov (United States)

    Favalora, Gregg E.; Dorval, Rick K.; Hall, Deirdre M.; Giovinco, Michael; Napoli, Joshua

    2001-06-01

    An 8-color multiplanar volumetric display is being developed by Actuality Systems, Inc. It will be capable of utilizing an image volume greater than 90 million voxels, which we believe is the greatest utilizable voxel set of any volumetric display constructed to date. The display is designed to be used for molecular visualization, mechanical CAD, e-commerce, entertainment, and medical imaging. As such, it contains a new graphics processing architecture, novel high-performance line- drawing algorithms, and an API similar to a current standard. Three-dimensional imagery is created by projecting a series of 2-D bitmaps ('image slices') onto a diffuse screen that rotates at 600 rpm. Persistence of vision fuses the slices into a volume-filling 3-D image. A modified three-panel Texas Instruments projector provides slices at approximately 4 kHz, resulting in 8-color 3-D imagery comprised of roughly 200 radially-disposed slices which are updated at 20 Hz. Each slice has a resolution of 768 by 768 pixels, subtending 10 inches. An unusual off-axis projection scheme incorporating tilted rotating optics is used to maintain good focus across the projection screen. The display electronics includes a custom rasterization architecture which converts the user's 3- D geometry data into image slices, as well as 6 Gbits of DDR SDRAM graphics memory.

  15. Myocardial kinematics based on tagged MRI from volumetric NURBS models

    Science.gov (United States)

    Tustison, Nicholas J.; Amini, Amir A.

    2004-04-01

    We present current research in which left ventricular deformation is estimated from tagged cardiac magnetic resonance imaging using volumetric deformable models constructed from nonuniform rational B-splines (NURBS). From a set of short and long axis images at end-diastole, the initial NURBS model is constructed by fitting two surfaces with the same parameterization to the set of epicardial and endocardial contours from which a volumetric model is created. Using normal displacements of the three sets of orthogonal tag planes as well as displacements of both tag line and contour/tag line intersection points, one can solve for the optimal homogeneous coordinates, in a least squares sense, of the control points of the NURBS model at a later time point using quadratic programming. After fitting to all time points of data, lofting the NURBS model at each time point creates a comprehensive 4-D NURBS model. From this model, we can extract 3-D myocardial displacement fields and corresponding strain maps, which are local measures of non-rigid deformation.

  16. Volumetric breast density affects performance of digital screening mammography.

    Science.gov (United States)

    Wanders, Johanna O P; Holland, Katharina; Veldhuis, Wouter B; Mann, Ritse M; Pijnappel, Ruud M; Peeters, Petra H M; van Gils, Carla H; Karssemeijer, Nico

    2017-02-01

    To determine to what extent automatically measured volumetric mammographic density influences screening performance when using digital mammography (DM). We collected a consecutive series of 111,898 DM examinations (2003-2011) from one screening unit of the Dutch biennial screening program (age 50-75 years). Volumetric mammographic density was automatically assessed using Volpara. We determined screening performance measures for four density categories comparable to the American College of Radiology (ACR) breast density categories. Of all the examinations, 21.6% were categorized as density category 1 ('almost entirely fatty') and 41.5, 28.9, and 8.0% as category 2-4 ('extremely dense'), respectively. We identified 667 screen-detected and 234 interval cancers. Interval cancer rates were 0.7, 1.9, 2.9, and 4.4‰ and false positive rates were 11.2, 15.1, 18.2, and 23.8‰ for categories 1-4, respectively (both p-trend density categories: 85.7, 77.6, 69.5, and 61.0% for categories 1-4, respectively (p-trend density, automatically measured on digital mammograms, impacts screening performance measures along the same patterns as established with ACR breast density categories. Since measuring breast density fully automatically has much higher reproducibility than visual assessment, this automatic method could help with implementing density-based supplemental screening.

  17. Volumetric properties of human islet amyloid polypeptide in liquid water.

    Science.gov (United States)

    Brovchenko, I; Andrews, M N; Oleinikova, A

    2010-04-28

    The volumetric properties of human islet amyloid polypeptide (hIAPP) in water were studied in a wide temperature range by computer simulations. The intrinsic density rho(p) and the intrinsic thermal expansion coefficient alpha(p) of hIAPP were evaluated by taking into account the difference between the volumetric properties of hydration and bulk water. The density of hydration water rho(h) was found to decrease almost linearly with temperature upon heating and its thermal expansion coefficient was found to be notably higher than that of bulk water. The peptide surface exposed to water is more hydrophobic and its rho(h) is smaller in conformation with a larger number of intrapeptide hydrogen bonds. The two hIAPP peptides studied (with and without disulfide bridge) show negative alpha(p), which is close to zero at 250 K and decreases to approximately -1.5 x 10(-3) K(-1) upon heating to 450 K. The analysis of various structural properties of peptides shows a correlation between the intrinsic peptide volumes and the number of intrapeptide hydrogen bonds. The obtained negative values of alpha(p) can be attributed to the shrinkage of the inner voids of the peptides upon heating.

  18. Volumetric verification of multiaxis machine tool using laser tracker.

    Science.gov (United States)

    Aguado, Sergio; Samper, David; Santolaria, Jorge; Aguilar, Juan José

    2014-01-01

    This paper aims to present a method of volumetric verification in machine tools with linear and rotary axes using a laser tracker. Beyond a method for a particular machine, it presents a methodology that can be used in any machine type. Along this paper, the schema and kinematic model of a machine with three axes of movement, two linear and one rotational axes, including the measurement system and the nominal rotation matrix of the rotational axis are presented. Using this, the machine tool volumetric error is obtained and nonlinear optimization techniques are employed to improve the accuracy of the machine tool. The verification provides a mathematical, not physical, compensation, in less time than other methods of verification by means of the indirect measurement of geometric errors of the machine from the linear and rotary axes. This paper presents an extensive study about the appropriateness and drawbacks of the regression function employed depending on the types of movement of the axes of any machine. In the same way, strengths and weaknesses of measurement methods and optimization techniques depending on the space available to place the measurement system are presented. These studies provide the most appropriate strategies to verify each machine tool taking into consideration its configuration and its available work space.

  19. The Volumetric Rate of Superluminous Supernovae at z~1

    CERN Document Server

    Prajs, S; Smith, M; Levan, A; Karpenka, N V; Edwards, T D P; Walker, C R; Wolf, W M; Balland, C; Carlberg, R; Howell, A; Lidman, C; Pain, R; Pritchet, C; Ruhlmann-Kleider, V

    2016-01-01

    We present a measurement of the volumetric rate of superluminous supernovae (SLSNe) at z~1, measured using archival data from the first four years of the Canada-France-Hawaii Telescope Supernova Legacy Survey (SNLS). We develop a method for the photometric classification of SLSNe to construct our sample. Our sample includes two previously spectroscopically-identified objects, and a further new candidate selected using our classification technique. We use the point-source recovery efficiencies from Perrett et.al. (2010) and a Monte Carlo approach to calculate the rate based on our SLSN sample. We find that the three identified SLSNe from SNLS give a rate of 91 (+76/-36) SNe/Yr/Gpc^3 at a volume-weighted redshift of z=1.13. This is equivalent to 2.2 (+1.8/-0.9) x10^-4 of the volumetric core collapse supernova rate at the same redshift. When combined with other rate measurements from the literature, we show that the rate of SLSNe increases with redshift in a manner consistent with that of the cosmic star formati...

  20. Bone Microarchitecture Assessed by HR-pQCT as Predictor of Fracture Risk in Postmenopausal Women: The OFELY Study.

    Science.gov (United States)

    Sornay-Rendu, Elisabeth; Boutroy, Stephanie; Duboeuf, François; Chapurlat, Roland D

    2017-03-09

    Several cross-sectional studies have shown that impairment of bone microarchitecture contributes to skeletal fragility. The aim of this study was to prospectively investigate the prediction of fracture (Fx) by bone microarchitecture assessed by high-resolution peripheral computed tomography (HR- pQCT) in postmenopausal women. We measured microarchitecture at the distal radius and tibia with HR-pQCT in the OFELY study, in addition to areal BMD with dual-energy X-ray absorptiometry (DXA) in 589 women, mean ± SD age 68 ± 9 years. During a median [IQ] 9.4 [1.0] years of follow-up, 135 women sustained an incident fragility Fx, including 81 women with a major osteoporotic Fx (MOP Fx). After adjustment for age, women who sustained Fx had significantly lower total and trabecular volumetric densities (vBMD) at both sites, cortical parameters (area and thickness at the radius, vBMD at the tibia), trabecular number (Tb.N), connectivity density (Conn.D), stiffness, and estimated failure load at both sites, compared with control women. After adjustment for age, current smoking, falls, prior Fx, use of osteoporosis-related drugs, and total hip BMD, each quartile decrease of several baseline values of bone microarchitecture at the radius was associated with significant change of the risk of Fx (HR of 1.39 for Tb.BMD [p = 0.001], 1.32 for Tb.N [p = 0.01], 0.76 for Tb.Sp.SD [p = 0.01], 1.49 [p = 0.01] for Conn.D, and 1.27 for stiffness [p = 0.02]). At the tibia, the association remained significant for stiffness and failure load in the multivariate model for all fragility Fx and for Tt.BMD, stiffness, and failure load for MOP Fx. We conclude that impairment of bone microarchitecture-essentially in the trabecular compartment of the radius-predict the occurrence of incident fracture in postmenopausal women. This assessment may play an important role in identifying women at high risk of fracture who could not be adequately detected by BMD measurement

  1. Differences in Trabecular Microstructure Between Black and White Women Assessed by Individual Trabecular Segmentation Analysis of HR-pQCT Images.

    Science.gov (United States)

    Putman, Melissa S; Yu, Elaine W; Lin, David; Darakananda, Karin; Finkelstein, Joel S; Bouxsein, Mary L

    2017-05-01

    Black women have lower fracture risk compared with white women, which may be partly explained by improved volumetric bone mineral density (vBMD) and bone microarchitecture primarily within the cortical bone compartment. To determine if there are differences in trabecular microstructure, connectivity, and alignment according to race/ethnicity, we performed individual trabecular segmentation (ITS) analyses on high-resolution peripheral quantitative computed tomography (HR-pQCT) scans of the distal radius and tibia in 273 peri- and postmenopausal black (n = 100) and white (n = 173) women participating in the Study of Women's Health Across the Nation in Boston. Unadjusted analyses showed that black women had greater trabecular plate volume fraction, plate thickness, plate number density, and plate surface area along with greater axial alignment of trabeculae, whereas white women had greater trabecular rod tissue fraction (p < 0.05 for all). Adjustment for clinical covariates augmented these race/ethnicity-related differences in plates and rods, such that white women had greater trabecular rod number density and rod-rod connectivity, whereas black women continued to have superior plate structural characteristics and axial alignment (p < 0.05 for all). These differences remained significant after adjustment for hip BMD and trabecular vBMD. In conclusion, black women had more plate-like trabecular morphology and higher axial alignment of trabeculae, whereas white women had more rod-like trabeculae. These differences may contribute to the improved bone strength and lower fracture risk observed in black women. © 2016 American Society for Bone and Mineral Research. © 2016 American Society for Bone and Mineral Research.

  2. Rapid mapping of volumetric machine errors using distance measurements

    Energy Technology Data Exchange (ETDEWEB)

    Krulewich, D.A.

    1998-04-01

    This paper describes a relatively inexpensive, fast, and easy to execute approach to maping the volumetric errors of a machine tool, coordinate measuring machine, or robot. An error map is used to characterize a machine or to improve its accuracy by compensating for the systematic errors. The method consists of three steps: (1) models the relationship between volumetric error and the current state of the machine, (2) acquiring error data based on distance measurements throughout the work volume; and (3)fitting the error model using the nonlinear equation for the distance. The error model is formulated from the kinematic relationship among the six degrees of freedom of error an each moving axis. Expressing each parametric error as function of position each is combined to predict the error between the functional point and workpiece, also as a function of position. A series of distances between several fixed base locations and various functional points in the work volume is measured using a Laser Ball Bar (LBB). Each measured distance is a non-linear function dependent on the commanded location of the machine, the machine error, and the location of the base locations. Using the error model, the non-linear equation is solved producing a fit for the error model Also note that, given approximate distances between each pair of base locations, the exact base locations in the machine coordinate system determined during the non-linear filling procedure. Furthermore, with the use of 2048 more than three base locations, bias error in the measuring instrument can be removed The volumetric errors of three-axis commercial machining center have been mapped using this procedure. In this study, only errors associated with the nominal position of the machine were considered Other errors such as thermally induced and load induced errors were not considered although the mathematical model has the ability to account for these errors. Due to the proprietary nature of the projects we are

  3. Quantitative volumetric Raman imaging of three dimensional cell cultures

    Science.gov (United States)

    Kallepitis, Charalambos; Bergholt, Mads S.; Mazo, Manuel M.; Leonardo, Vincent; Skaalure, Stacey C.; Maynard, Stephanie A.; Stevens, Molly M.

    2017-03-01

    The ability to simultaneously image multiple biomolecules in biologically relevant three-dimensional (3D) cell culture environments would contribute greatly to the understanding of complex cellular mechanisms and cell-material interactions. Here, we present a computational framework for label-free quantitative volumetric Raman imaging (qVRI). We apply qVRI to a selection of biological systems: human pluripotent stem cells with their cardiac derivatives, monocytes and monocyte-derived macrophages in conventional cell culture systems and mesenchymal stem cells inside biomimetic hydrogels that supplied a 3D cell culture environment. We demonstrate visualization and quantification of fine details in cell shape, cytoplasm, nucleus, lipid bodies and cytoskeletal structures in 3D with unprecedented biomolecular specificity for vibrational microspectroscopy.

  4. Optimization approaches to volumetric modulated arc therapy planning

    Energy Technology Data Exchange (ETDEWEB)

    Unkelbach, Jan, E-mail: junkelbach@mgh.harvard.edu; Bortfeld, Thomas; Craft, David [Department of Radiation Oncology, Massachusetts General Hospital and Harvard Medical School, Boston, Massachusetts 02114 (United States); Alber, Markus [Department of Medical Physics and Department of Radiation Oncology, Aarhus University Hospital, Aarhus C DK-8000 (Denmark); Bangert, Mark [Department of Medical Physics in Radiation Oncology, German Cancer Research Center, Heidelberg D-69120 (Germany); Bokrantz, Rasmus [RaySearch Laboratories, Stockholm SE-111 34 (Sweden); Chen, Danny [Department of Computer Science and Engineering, University of Notre Dame, Notre Dame, Indiana 46556 (United States); Li, Ruijiang; Xing, Lei [Department of Radiation Oncology, Stanford University, Stanford, California 94305 (United States); Men, Chunhua [Department of Research, Elekta, Maryland Heights, Missouri 63043 (United States); Nill, Simeon [Joint Department of Physics at The Institute of Cancer Research and The Royal Marsden NHS Foundation Trust, London SM2 5NG (United Kingdom); Papp, Dávid [Department of Mathematics, North Carolina State University, Raleigh, North Carolina 27695 (United States); Romeijn, Edwin [H. Milton Stewart School of Industrial and Systems Engineering, Georgia Institute of Technology, Atlanta, Georgia 30332 (United States); Salari, Ehsan [Department of Industrial and Manufacturing Engineering, Wichita State University, Wichita, Kansas 67260 (United States)

    2015-03-15

    Volumetric modulated arc therapy (VMAT) has found widespread clinical application in recent years. A large number of treatment planning studies have evaluated the potential for VMAT for different disease sites based on the currently available commercial implementations of VMAT planning. In contrast, literature on the underlying mathematical optimization methods used in treatment planning is scarce. VMAT planning represents a challenging large scale optimization problem. In contrast to fluence map optimization in intensity-modulated radiotherapy planning for static beams, VMAT planning represents a nonconvex optimization problem. In this paper, the authors review the state-of-the-art in VMAT planning from an algorithmic perspective. Different approaches to VMAT optimization, including arc sequencing methods, extensions of direct aperture optimization, and direct optimization of leaf trajectories are reviewed. Their advantages and limitations are outlined and recommendations for improvements are discussed.

  5. Volumetric properties of water/AOT/isooctane microemulsions.

    Science.gov (United States)

    Du, Changfei; He, Wei; Yin, Tianxiang; Shen, Weiguo

    2014-12-23

    The densities of AOT/isooctane micelles and water/AOT/isooctane microemulsions with the molar ratios R of water to AOT being 2, 8, 10, 12, 16, 18, 20, 25, 30, and 40 were measured at 303.15 K. The apparent specific volumes of AOT and the quasi-component water/AOT at various concentrations were calculated and used to estimate the volumetric properties of AOT and water in the droplets and in the continuous oil phase, to discuss the interaction between the droplets, and to determine the critical micelle concentration and the critical microemulsion concentrations. A thermodynamic model was proposed to analysis the stability boundary of the microemulsion droplets, which confirms the maximum value of R being about 65 for the stable AOT/water/isooctane microemulsion droplets.

  6. Quantitative volumetric Raman imaging of three dimensional cell cultures

    KAUST Repository

    Kallepitis, Charalambos

    2017-03-22

    The ability to simultaneously image multiple biomolecules in biologically relevant three-dimensional (3D) cell culture environments would contribute greatly to the understanding of complex cellular mechanisms and cell–material interactions. Here, we present a computational framework for label-free quantitative volumetric Raman imaging (qVRI). We apply qVRI to a selection of biological systems: human pluripotent stem cells with their cardiac derivatives, monocytes and monocyte-derived macrophages in conventional cell culture systems and mesenchymal stem cells inside biomimetic hydrogels that supplied a 3D cell culture environment. We demonstrate visualization and quantification of fine details in cell shape, cytoplasm, nucleus, lipid bodies and cytoskeletal structures in 3D with unprecedented biomolecular specificity for vibrational microspectroscopy.

  7. In-line hologram segmentation for volumetric samples.

    Science.gov (United States)

    Orzó, László; Göröcs, Zoltán; Fehér, András; Tőkés, Szabolcs

    2013-01-01

    We propose a fast, noniterative method to segment an in-line hologram of a volumetric sample into in-line subholograms according to its constituent objects. In contrast to the phase retrieval or twin image elimination algorithms, we do not aim or require to reconstruct the complex wave field of all the objects, which would be a more complex task, but only provide a good estimate about the contribution of the particular objects to the original hologram quickly. The introduced hologram segmentation algorithm exploits the special inner structure of the in-line holograms and applies only the estimated supports and reconstruction distances of the corresponding objects as parameters. The performance of the proposed method is demonstrated and analyzed experimentally both on synthetic and measured holograms. We discussed how the proposed algorithm can be efficiently applied for object reconstruction and phase retrieval tasks.

  8. Three-Dimensional Volumetric Restoration by Structural Fat Grafting

    Science.gov (United States)

    Clauser, Luigi C.; Consorti, Giuseppe; Elia, Giovanni; Galié, Manlio; Tieghi, Riccardo

    2013-01-01

    The use of adipose tissue transfer for correction of maxillofacial defects was reported for the first time at the end of the 19th century. Structural fat grafting (SFG) was introduced as a way to improve facial esthetics and in recent years has evolved into applications in craniomaxillofacial reconstructive surgery. Several techniques have been proposed for harvesting and grafting the fat. However, owing to the damage of many adipocytes during these maneuvers, the results have not been satisfactory and have required several fat injection procedures for small corrections. The author's (L.C.) overview the application of SFG in the management of volumetric deficit in the craniomaxillofacial in patients treated with a long-term follow-up. PMID:24624259

  9. Semi-automatic volumetrics system to parcellate ROI on neocortex

    Science.gov (United States)

    Tan, Ou; Ichimiya, Tetsuya; Yasuno, Fumihiko; Suhara, Tetsuya

    2002-05-01

    A template-based and semi-automatic volumetrics system--BrainVol is build to divide the any given patient brain to neo-cortical and sub-cortical regions. The standard region is given as standard ROI drawn on a standard brain volume. After normalization between the standard MR image and the patient MR image, the sub-cortical ROIs' boundary are refined based on gray matter. The neo-cortical ROIs are refined by sulcus information that is semi-automatically marked on the patient brain. Then the segmentation is applied to 4D PET image of same patient for calculation of TAC (Time Activity Curve) by co-registration between MR and PET.

  10. Out-of-core clustering of volumetric datasets

    Institute of Scientific and Technical Information of China (English)

    GRANBERG Carl J.; LI Ling

    2006-01-01

    In this paper we present a novel method for dividing and clustering large volumetric scalar out-of-core datasets. This work is based on the Ordered Cluster Binary Tree (OCBT) structure created using a top-down or divisive clustering method. The OCBT structure allows fast and efficient sub volume queries to be made in combination with level of detail (LOD) queries of the tree. The initial partitioning of the large out-of-core dataset is done by using non-axis aligned planes calculated using Principal Component Analysis (PCA). A hybrid OCBT structure is also proposed where an in-core cluster binary tree is combined with a large out-of-core file.

  11. Volumetric Survey Speed: A Figure of Merit for Transient Surveys

    CERN Document Server

    Bellm, Eric C

    2016-01-01

    Time-domain surveys can exchange sky coverage for revisit frequency, complicating the comparison of their relative capabilities. By using different revisit intervals, a specific camera may execute surveys optimized for discovery of different classes of transient objects. We propose a new figure of merit, the instantaneous volumetric survey speed, for evaluating transient surveys. This metric defines the trade between cadence interval and snapshot survey volume and so provides a natural means of comparing survey capability. The related metric of areal survey speed imposes a constraint on the range of possible revisit times: we show that many modern time-domain surveys are limited by the amount of fresh sky available each night. We introduce the concept of "spectroscopic accessibility" and discuss its importance for transient science goals requiring followup observing. We present an extension of the control time algorithm for cases where multiple consecutive detections are required. Finally, we explore how surv...

  12. Volumetric optical coherence microscopy enabled by aberrated optics (Conference Presentation)

    Science.gov (United States)

    Mulligan, Jeffrey A.; Liu, Siyang; Adie, Steven G.

    2017-02-01

    Optical coherence microscopy (OCM) is an interferometric imaging technique that enables high resolution, non-invasive imaging of 3D cell cultures and biological tissues. Volumetric imaging with OCM suffers a trade-off between high transverse resolution and poor depth-of-field resulting from defocus, optical aberrations, and reduced signal collection away from the focal plane. While defocus and aberrations can be compensated with computational methods such as interferometric synthetic aperture microscopy (ISAM) or computational adaptive optics (CAO), reduced signal collection must be physically addressed through optical hardware. Axial scanning of the focus is one approach, but comes at the cost of longer acquisition times, larger datasets, and greater image reconstruction times. Given the capabilities of CAO to compensate for general phase aberrations, we present an alternative method to address the signal collection problem without axial scanning by using intentionally aberrated optical hardware. We demonstrate the use of an astigmatic spectral domain (SD-)OCM imaging system to enable single-acquisition volumetric OCM in 3D cell culture over an extended depth range, compared to a non-aberrated SD-OCM system. The transverse resolution of the non-aberrated and astigmatic imaging systems after application of CAO were 2 um and 2.2 um, respectively. The depth-range of effective signal collection about the nominal focal plane was increased from 100 um in the non-aberrated system to over 300 um in the astigmatic system, extending the range over which useful data may be acquired in a single OCM dataset. We anticipate that this method will enable high-throughput cellular-resolution imaging of dynamic biological systems over extended volumes.

  13. Marginal Space Deep Learning: Efficient Architecture for Volumetric Image Parsing.

    Science.gov (United States)

    Ghesu, Florin C; Krubasik, Edward; Georgescu, Bogdan; Singh, Vivek; Yefeng Zheng; Hornegger, Joachim; Comaniciu, Dorin

    2016-05-01

    Robust and fast solutions for anatomical object detection and segmentation support the entire clinical workflow from diagnosis, patient stratification, therapy planning, intervention and follow-up. Current state-of-the-art techniques for parsing volumetric medical image data are typically based on machine learning methods that exploit large annotated image databases. Two main challenges need to be addressed, these are the efficiency in scanning high-dimensional parametric spaces and the need for representative image features which require significant efforts of manual engineering. We propose a pipeline for object detection and segmentation in the context of volumetric image parsing, solving a two-step learning problem: anatomical pose estimation and boundary delineation. For this task we introduce Marginal Space Deep Learning (MSDL), a novel framework exploiting both the strengths of efficient object parametrization in hierarchical marginal spaces and the automated feature design of Deep Learning (DL) network architectures. In the 3D context, the application of deep learning systems is limited by the very high complexity of the parametrization. More specifically 9 parameters are necessary to describe a restricted affine transformation in 3D, resulting in a prohibitive amount of billions of scanning hypotheses. The mechanism of marginal space learning provides excellent run-time performance by learning classifiers in clustered, high-probability regions in spaces of gradually increasing dimensionality. To further increase computational efficiency and robustness, in our system we learn sparse adaptive data sampling patterns that automatically capture the structure of the input. Given the object localization, we propose a DL-based active shape model to estimate the non-rigid object boundary. Experimental results are presented on the aortic valve in ultrasound using an extensive dataset of 2891 volumes from 869 patients, showing significant improvements of up to 45

  14. The volumetric rate of superluminous supernovae at z ˜ 1

    Science.gov (United States)

    Prajs, S.; Sullivan, M.; Smith, M.; Levan, A.; Karpenka, N. V.; Edwards, T. D. P.; Walker, C. R.; Wolf, W. M.; Balland, C.; Carlberg, R.; Howell, D. A.; Lidman, C.; Pain, R.; Pritchet, C.; Ruhlmann-Kleider, V.

    2017-01-01

    We present a measurement of the volumetric rate of superluminous supernovae (SLSNe) at z ˜ 1.0, measured using archival data from the first four years of the Canada-France-Hawaii Telescope Supernova Legacy Survey (SNLS). We develop a method for the photometric classification of SLSNe to construct our sample. Our sample includes two previously spectroscopically identified objects, and a further new candidate selected using our classification technique. We use the point-source recovery efficiencies from Perrett et al. and a Monte Carlo approach to calculate the rate based on our SLSN sample. We find that the three identified SLSNe from SNLS give a rate of 91^{+76}_{-36} SNe yr-1 Gpc-3 at a volume-weighted redshift of z = 1.13. This is equivalent to 2.2^{+1.8}_{-0.9}× 10^{-4} of the volumetric core-collapse supernova rate at the same redshift. When combined with other rate measurements from the literature, we show that the rate of SLSNe increases with redshift in a manner consistent with that of the cosmic star formation history. We also estimate the rate of ultra-long gamma-ray bursts based on the events discovered by the Swift satellite, and show that it is comparable to the rate of SLSNe, providing further evidence of a possible connection between these two classes of events. We also examine the host galaxies of the SLSNe discovered in SNLS, and find them to be consistent with the stellar-mass distribution of other published samples of SLSNe.

  15. Volumetric analysis of corticocancellous bones using CT data

    Energy Technology Data Exchange (ETDEWEB)

    Krappinger, Dietmar; Linde, Astrid von; Rosenberger, Ralf; Blauth, Michael [Medical University Innsbruck, Department of Trauma Surgery and Sports Medicine, Innsbruck (Austria); Glodny, Bernhard; Niederwanger, Christian [Medical University Innsbruck, Department of Radiology I, Innsbruck (Austria)

    2012-05-15

    To present a method for an automated volumetric analysis of corticocancellous bones such as the superior pubic ramus using CT data and to assess the reliability of this method. Computed tomography scans of a consecutive series of 250 patients were analyzed. A Hounsfield unit (HU) thresholding-based reconstruction technique (''Vessel Tracking,'' GE Healthcare) was used. A contiguous space of cancellous bone with similar HU values between the starting and end points was automatically identified as the region of interest. The identification was based upon the density gradient to the adjacent cortical bone. The starting point was defined as the middle of the parasymphyseal corticocancellous transition zone on the axial slice showing the parasymphyseal superior pubic ramus in its maximum anteroposterior width. The end point was defined as the middle of the periarticular corticocancellous transition zone on the axial slice showing the quadrilateral plate as a thin cortical plate. The following parameters were automatically obtained on both sides: length of the center line, volume of the superior pubic ramus between the starting point and end point, minimum, maximum and mean diameter perpendicular to the center line, and mean cross-sectional area perpendicular to the center line. An automated analysis without manual adjustments was successful in 207 patients (82.8%). The center line showed a significantly greater length in female patients (67.6 mm vs 65.0 mm). The volume was greater in male patients (21.8 cm{sup 3} vs 19.4 cm{sup 3}). The intersite reliability was high with a mean difference between the left and right sides of between 0.1% (cross-sectional area) and 2.3% (volume). The method presented allows for an automated volumetric analysis of a corticocancellous bone using CT data. The method is intended to provide preoperative information for the use of intramedullary devices in fracture fixation and percutaneous cement augmentation techniques

  16. An Analysis Methodology for Stochastic Characteristic of Volumetric Error in Multiaxis CNC Machine Tool

    Directory of Open Access Journals (Sweden)

    Qiang Cheng

    2013-01-01

    Full Text Available Traditional approaches about error modeling and analysis of machine tool few consider the probability characteristics of the geometric error and volumetric error systematically. However, the individual geometric error measured at different points is variational and stochastic, and therefore the resultant volumetric error is aslo stochastic and uncertain. In order to address the stochastic characteristic of the volumetric error for multiaxis machine tool, a new probability analysis mathematical model of volumetric error is proposed in this paper. According to multibody system theory, a mean value analysis model for volumetric error is established with consideration of geometric errors. The probability characteristics of geometric errors are obtained by statistical analysis to the measured sample data. Based on probability statistics and stochastic process theory, the variance analysis model of volumetric error is established in matrix, which can avoid the complex mathematics operations during the direct differential. A four-axis horizontal machining center is selected as an illustration example. The analysis results can reveal the stochastic characteristic of volumetric error and are also helpful to make full use of the best workspace to reduce the random uncertainty of the volumetric error and improve the machining accuracy.

  17. Volumetric and two-dimensional image interpretation show different cognitive processes in learners

    NARCIS (Netherlands)

    van der Gijp, Anouk; Ravesloot, C.J.; van der Schaaf, Marieke F; van der Schaaf, Irene C; Huige, Josephine C B M; Vincken, Koen L; Ten Cate, Olle Th J; van Schaik, JPJ

    2015-01-01

    RATIONALE AND OBJECTIVES: In current practice, radiologists interpret digital images, including a substantial amount of volumetric images. We hypothesized that interpretation of a stack of a volumetric data set demands different skills than interpretation of two-dimensional (2D) cross-sectional imag

  18. High Volumetric Energy Density Hybrid Supercapacitors Based on Reduced Graphene Oxide Scrolls.

    Science.gov (United States)

    Rani, Janardhanan R; Thangavel, Ranjith; Oh, Se-I; Woo, Jeong Min; Chandra Das, Nayan; Kim, So-Yeon; Lee, Yun-Sung; Jang, Jae-Hyung

    2017-07-12

    The low volumetric energy density of reduced graphene oxide (rGO)-based electrodes limits its application in commercial electrochemical energy storage devices that require high-performance energy storage capacities in small volumes. The volumetric energy density of rGO-based electrode materials is very low due to their low packing density. A supercapacitor with enhanced packing density and high volumetric energy density is fabricated using doped rGO scrolls (GFNSs) as the electrode material. The restacking of rGO sheets is successfully controlled through synthesizing the doped scroll structures while increasing the packing density. The fabricated cell exhibits an ultrahigh volumetric energy density of 49.66 Wh/L with excellent cycling stability (>10 000 cycles). This unique design strategy for the electrode material has significant potential for the future supercapacitors with high volumetric energy densities.

  19. Global segmentation and curvature analysis of volumetric data sets using trivariate B-spline functions.

    Science.gov (United States)

    Soldea, Octavian; Elber, Gershon; Rivlin, Ehud

    2006-02-01

    This paper presents a method to globally segment volumetric images into regions that contain convex or concave (elliptic) iso-surfaces, planar or cylindrical (parabolic) iso-surfaces, and volumetric regions with saddle-like (hyperbolic) iso-surfaces, regardless of the value of the iso-surface level. The proposed scheme relies on a novel approach to globally compute, bound, and analyze the Gaussian and mean curvatures of an entire volumetric data set, using a trivariate B-spline volumetric representation. This scheme derives a new differential scalar field for a given volumetric scalar field, which could easily be adapted to other differential properties. Moreover, this scheme can set the basis for more precise and accurate segmentation of data sets targeting the identification of primitive parts. Since the proposed scheme employs piecewise continuous functions, it is precise and insensitive to aliasing.

  20. The duct selective volumetric receiver: potential for different selectivity strategies and stability issues

    Energy Technology Data Exchange (ETDEWEB)

    Garcia-Casals, X. [Universidad Pontificia Comillas-ICAI, Madrid (Spain). Dept. de Fluidos y Calor; Ajona, J.I. [Departamento de Energia Solar, Viessemann, Poligono Industrial San Marcos, Getafe (Spain)

    1999-07-01

    Recently much theoretical and experimental work has been conducted on volumetric receivers. However, not much attention has been paid to the possibilities of using different selectivity mechanisms to minimize radiation thermal losses, which are the main ones at high operating temperature. In this paper we present a duct volumetric receiver model and its results, which allow the evaluation of different selectivity strategies such as: conventional {epsilon}/{alpha}, geometry, frontal absorption and diffuse/specular reflection. We propose a new concept of selective volumetric receivers based on a solar-specular/infrared-diffuse radiative behaviour and evaluate its potential for efficiency improvement. In recent work on volumetric receivers based on simplified models, it has been concluded that the duct volumetric receiver is inherently unstable when working with high solar flux. We didn't find any unstable receiver behaviour even at very high solar fluxes, and conclude that a substantial potential for efficiency improvement exists if selectivity mechanisms are properly combined. (author)

  1. Enhanced volumetric visualization for real time 4D intraoperative ophthalmic swept-source OCT.

    Science.gov (United States)

    Viehland, Christian; Keller, Brenton; Carrasco-Zevallos, Oscar M; Nankivil, Derek; Shen, Liangbo; Mangalesh, Shwetha; Viet, Du Tran; Kuo, Anthony N; Toth, Cynthia A; Izatt, Joseph A

    2016-05-01

    Current-generation software for rendering volumetric OCT data sets based on ray casting results in volume visualizations with indistinct tissue features and sub-optimal depth perception. Recent developments in hand-held and microscope-integrated intrasurgical OCT designed for real-time volumetric imaging motivate development of rendering algorithms which are both visually appealing and fast enough to support real time rendering, potentially from multiple viewpoints for stereoscopic visualization. We report on an enhanced, real time, integrated volumetric rendering pipeline which incorporates high performance volumetric median and Gaussian filtering, boundary and feature enhancement, depth encoding, and lighting into a ray casting volume rendering model. We demonstrate this improved model implemented on graphics processing unit (GPU) hardware for real-time volumetric rendering of OCT data during tissue phantom and live human surgical imaging. We show that this rendering produces enhanced 3D visualizations of pathology and intraoperative maneuvers compared to standard ray casting.

  2. Volumetric and two-dimensional image interpretation show different cognitive processes in learners.

    Science.gov (United States)

    van der Gijp, Anouk; Ravesloot, Cécile J; van der Schaaf, Marieke F; van der Schaaf, Irene C; Huige, Josephine C B M; Vincken, Koen L; Ten Cate, Olle Th J; van Schaik, Jan P J

    2015-05-01

    In current practice, radiologists interpret digital images, including a substantial amount of volumetric images. We hypothesized that interpretation of a stack of a volumetric data set demands different skills than interpretation of two-dimensional (2D) cross-sectional images. This study aimed to investigate and compare knowledge and skills used for interpretation of volumetric versus 2D images. Twenty radiology clerks were asked to think out loud while reading four or five volumetric computed tomography (CT) images in stack mode and four or five 2D CT images. Cases were presented in a digital testing program allowing stack viewing of volumetric data sets and changing views and window settings. Thoughts verbalized by the participants were registered and coded by a framework of knowledge and skills concerning three components: perception, analysis, and synthesis. The components were subdivided into 16 discrete knowledge and skill elements. A within-subject analysis was performed to compare cognitive processes during volumetric image readings versus 2D cross-sectional image readings. Most utterances contained knowledge and skills concerning perception (46%). A smaller part involved synthesis (31%) and analysis (23%). More utterances regarded perception in volumetric image interpretation than in 2D image interpretation (Median 48% vs 35%; z = -3.9; P Cognitive processes in volumetric and 2D cross-sectional image interpretation differ substantially. Volumetric image interpretation draws predominantly on perceptual processes, whereas 2D image interpretation is mainly characterized by synthesis. The results encourage the use of volumetric images for teaching and testing perceptual skills. Copyright © 2015 AUR. Published by Elsevier Inc. All rights reserved.

  3. Effect of supplementation of diets with BMD and Virginiamycin on the growth performance, carcass characteristics and bacterial population in broiler chickens

    Directory of Open Access Journals (Sweden)

    Manoj Singh

    2008-10-01

    Full Text Available Broiler chicks of a commercial strain were fed diets containing Bacitracin Methylene Disalicylate @150 g and 200 g/MT and Virginiamycin 500g/MT feed upto 6 weeks of age to evaluate their effects on growth, feed efficiency, carcass characteristics and bacterial population (Salmonella and E. coli. Both BMD and virginiamycin significantly increased (P<0.01 the body weight gains as compare to the control and also improve the feed conversion ratio. The carcass characteristics showed the highest edible weight was recorded in treatment IV where virginiamycin @ 500g/MT feed was incorporated (76.86%, followed by treatment III (71.92%, treatment II (71.41% and the lowest (70.68 in control (T-I. The sample of excreta collected during II, IV and VI week of experiment did not show any incidences of Salmonella in any treatment groups, however, the excreta of six week in all the treatment groups showed the incidences of E. coli. [Veterinary World 2008; 1(5.000: 141-143

  4. Calcaneal BMD Obtained by Dual X-Ray and Laser Predicts Future Hip Fractures—A Prospective Study on 4 398 Swedish Women

    Directory of Open Access Journals (Sweden)

    Torkel B. Brismar

    2010-01-01

    Full Text Available The predictive value of dual X-ray and laser (DXL calcaneal BMD (BMDDXL on hip fractures was prospectively studied in 4,398 females aged 55 to 99 years. The average follow-up period was 3 years and 11 months with a total of 17,270 person years. Fractures were identified from the national patient register. After inclusion, 130 females sustained a hip fracture. The age adjusted hazard ratio for T-score −2.5 was 2.64. Of all patients who sustained a hip fracture 78% had a T-score of −2.5 or below. The annual hip fracture rate was 0.26% at T-scores ≥−2, but 1.5% at T-scores ≤−2.5. The area under curve for the model including calcaneal BMDDXL, follow-up time, and age to prospectively predict hip fractures was 0.84. Conclusions. Calcaneal BMDDXL obtained by DXL Calscan predicts hip fractures and may therefore be suitable for diagnosing osteoporosis and for predicting fracture risk.

  5. Volumetric Spectroscopic Imaging of Glioblastoma Multiforme Radiation Treatment Volumes

    Energy Technology Data Exchange (ETDEWEB)

    Parra, N. Andres [Department of Radiation Oncology, University of Miami Miller School of Medicine, Miami, Florida (United States); Maudsley, Andrew A. [Department of Radiology, University of Miami Miller School of Medicine, Miami, Florida (United States); Gupta, Rakesh K. [Department of Radiology and Imaging, Fortis Memorial Research Institute, Gurgaon, Haryana (India); Ishkanian, Fazilat; Huang, Kris [Department of Radiation Oncology, University of Miami Miller School of Medicine, Miami, Florida (United States); Walker, Gail R. [Biostatistics and Bioinformatics Core Resource, Sylvester Cancer Center, University of Miami Miller School of Medicine, Miami, Florida (United States); Padgett, Kyle [Department of Radiation Oncology, University of Miami Miller School of Medicine, Miami, Florida (United States); Department of Radiology, University of Miami Miller School of Medicine, Miami, Florida (United States); Roy, Bhaswati [Department of Radiology and Imaging, Fortis Memorial Research Institute, Gurgaon, Haryana (India); Panoff, Joseph; Markoe, Arnold [Department of Radiation Oncology, University of Miami Miller School of Medicine, Miami, Florida (United States); Stoyanova, Radka, E-mail: RStoyanova@med.miami.edu [Department of Radiation Oncology, University of Miami Miller School of Medicine, Miami, Florida (United States)

    2014-10-01

    Purpose: Magnetic resonance (MR) imaging and computed tomography (CT) are used almost exclusively in radiation therapy planning of glioblastoma multiforme (GBM), despite their well-recognized limitations. MR spectroscopic imaging (MRSI) can identify biochemical patterns associated with normal brain and tumor, predominantly by observation of choline (Cho) and N-acetylaspartate (NAA) distributions. In this study, volumetric 3-dimensional MRSI was used to map these compounds over a wide region of the brain and to evaluate metabolite-defined treatment targets (metabolic tumor volumes [MTV]). Methods and Materials: Volumetric MRSI with effective voxel size of ∼1.0 mL and standard clinical MR images were obtained from 19 GBM patients. Gross tumor volumes and edema were manually outlined, and clinical target volumes (CTVs) receiving 46 and 60 Gy were defined (CTV{sub 46} and CTV{sub 60}, respectively). MTV{sub Cho} and MTV{sub NAA} were constructed based on volumes with high Cho and low NAA relative to values estimated from normal-appearing tissue. Results: The MRSI coverage of the brain was between 70% and 76%. The MTV{sub NAA} were almost entirely contained within the edema, and the correlation between the 2 volumes was significant (r=0.68, P=.001). In contrast, a considerable fraction of MTV{sub Cho} was outside of the edema (median, 33%) and for some patients it was also outside of the CTV{sub 46} and CTV{sub 60}. These untreated volumes were greater than 10% for 7 patients (37%) in the study, and on average more than one-third (34.3%) of the MTV{sub Cho} for these patients were outside of CTV{sub 60}. Conclusions: This study demonstrates the potential usefulness of whole-brain MRSI for radiation therapy planning of GBM and revealed that areas of metabolically active tumor are not covered by standard RT volumes. The described integration of MTV into the RT system will pave the way to future clinical trials investigating outcomes in patients treated based on

  6. Volumetric capnography for the evaluation of chronic airways diseases

    Directory of Open Access Journals (Sweden)

    Veronez L

    2014-09-01

    Full Text Available Liliani de Fátima Veronez,1 Monica Corso Pereira,2 Silvia Maria Doria da Silva,2 Luisa Affi Barcaui,2 Eduardo Mello De Capitani,2 Marcos Mello Moreira,2 Ilma Aparecida Paschoalz2 1Department of Physical Therapy, University of Votuporanga (Educational Foundation of Votuporanga, Votuporanga, 2Department of Internal Medicine, School of Medical Sciences, State University of Campinas (UNICAMP, Campinas, Sao Paulo, BrazilBackground: Obstructive lung diseases of different etiologies present with progressive peripheral airway involvement. The peripheral airways, known as the silent lung zone, are not adequately evaluated with conventional function tests. The principle of gas washout has been used to detect pulmonary ventilation inhomogeneity and to estimate the location of the underlying disease process. Volumetric capnography (VC analyzes the pattern of CO2 elimination as a function of expired volume.Objective: To measure normalized phase 3 slopes with VC in patients with non-cystic fibrosis bronchiectasis (NCB and in bronchitic patients with chronic obstructive pulmonary disease (COPD in order to compare the slopes obtained for the groups.Methods: NCB and severe COPD were enrolled sequentially from an outpatient clinic (Hospital of the State University of Campinas. A control group was established for the NCB group, paired by sex and age. All subjects performed spirometry, VC, and the 6-Minute Walk Test (6MWT. Two comparisons were made: NCB group versus its control group, and NCB group versus COPD group. The project was approved by the ethical committee of the institution. Statistical tests used were Wilcoxon or Student’s t-test; P<0.05 was considered to be a statistically significant difference.Results: Concerning the NCB group (N=20 versus the control group (N=20, significant differences were found in body mass index and in several functional variables (spirometric, VC, 6MWT with worse results observed in the NCB group. In the comparison between

  7. Widespread Volumetric Brain Changes following Tooth Loss in Female Mice

    Science.gov (United States)

    Avivi-Arber, Limor; Seltzer, Ze'ev; Friedel, Miriam; Lerch, Jason P.; Moayedi, Massieh; Davis, Karen D.; Sessle, Barry J.

    2017-01-01

    Tooth loss is associated with altered sensory, motor, cognitive and emotional functions. These changes vary highly in the population and are accompanied by structural and functional changes in brain regions mediating these functions. It is unclear to what extent this variability in behavior and function is caused by genetic and/or environmental determinants and which brain regions undergo structural plasticity that mediates these changes. Thus, the overall goal of our research program is to identify genetic variants that control structural and functional plasticity following tooth loss. As a step toward this goal, here our aim was to determine whether structural magnetic resonance imaging (sMRI) is sensitive to detect quantifiable volumetric differences in the brains of mice of different genetic background receiving tooth extraction or sham operation. We used 67 adult female mice of 7 strains, comprising the A/J (A) and C57BL/6J (B) strains and a randomly selected sample of 5 of the 23 AXB-BXA strains (AXB1, AXB4, AXB24, BXA14, BXA24) that were produced from the A and B parental mice by recombinations and inbreeding. This panel of 25 inbred strains of genetically diverse inbred strains of mice is used for mapping chromosomal intervals throughout the genome that harbor candidate genes controlling the phenotypic variance of any trait under study. Under general anesthesia, 39 mice received extraction of 3 right maxillary molar teeth and 28 mice received sham operation. On post-extraction day 21, post-mortem whole-brain high-resolution sMRI was used to quantify the volume of 160 brain regions. Compared to sham operation, tooth extraction was associated with a significantly reduced regional and voxel-wise volumes of cortical brain regions involved in processing somatosensory, motor, cognitive and emotional functions, and increased volumes in subcortical sensorimotor and temporal limbic forebrain regions including the amygdala. Additionally, comparison of the 10 BXA14

  8. Hepatosplenic volumetric assessment at MDCT for staging liver fibrosis.

    Science.gov (United States)

    Pickhardt, Perry J; Malecki, Kyle; Hunt, Oliver F; Beaumont, Claire; Kloke, John; Ziemlewicz, Timothy J; Lubner, Meghan G

    2017-07-01

    To investigate hepatosplenic volumetry at MDCT for non-invasive prediction of hepatic fibrosis. Hepatosplenic volume analysis in 624 patients (mean age, 48.8 years; 311 M/313 F) at MDCT was performed using dedicated software and compared against pathological fibrosis stage (F0 = 374; F1 = 48; F2 = 40; F3 = 65; F4 = 97). The liver segmental volume ratio (LSVR) was defined by Couinaud segments I-III over segments IV-VIII. All pre-cirrhotic fibrosis stages (METAVIR F1-F3) were based on liver biopsy within 1 year of MDCT. LSVR and total splenic volumes increased with stage of fibrosis, with mean(±SD) values of: F0: 0.26 ± 0.06 and 215.1 ± 88.5 mm(3); F1: 0.25 ± 0.08 and 294.8 ± 153.4 mm(3); F2: 0.331 ± 0.12 and 291.6 ± 197.1 mm(3); F3: 0.39 ± 0.15 and 509.6 ± 402.6 mm(3); F4: 0.56 ± 0.30 and 790.7 ± 450.3 mm(3), respectively. Total hepatic volumes showed poor discrimination (F0: 1674 ± 320 mm(3); F4: 1631 ± 691 mm(3)). For discriminating advanced fibrosis (≥F3), the ROC AUC values for LSVR, total liver volume, splenic volume and LSVR/spleen combined were 0.863, 0.506, 0.890 and 0.947, respectively. Relative changes in segmental liver volumes and total splenic volume allow for non-invasive staging of hepatic fibrosis, whereas total liver volume is a poor predictor. Unlike liver biopsy or elastography, these CT volumetric biomarkers can be obtained retrospectively on routine scans obtained for other indications. • Regional changes in hepatic volume (LSVR) correlate well with degree of fibrosis. • Total liver volume is a very poor predictor of underlying fibrosis. • Total splenic volume is associated with the degree of hepatic fibrosis. • Hepatosplenic volume assessment is comparable to elastography for staging fibrosis. • Unlike elastography, volumetric analysis can be performed retrospectively.

  9. Volumetric and MGMT parameters in glioblastoma patients: Survival analysis

    Directory of Open Access Journals (Sweden)

    Iliadis Georgios

    2012-01-01

    Full Text Available Abstract Background In this study several tumor-related volumes were assessed by means of a computer-based application and a survival analysis was conducted to evaluate the prognostic significance of pre- and postoperative volumetric data in patients harboring glioblastomas. In addition, MGMT (O6-methylguanine methyltransferase related parameters were compared with those of volumetry in order to observe possible relevance of this molecule in tumor development. Methods We prospectively analyzed 65 patients suffering from glioblastoma (GBM who underwent radiotherapy with concomitant adjuvant temozolomide. For the purpose of volumetry T1 and T2-weighted magnetic resonance (MR sequences were used, acquired both pre- and postoperatively (pre-radiochemotherapy. The volumes measured on preoperative MR images were necrosis, enhancing tumor and edema (including the tumor and on postoperative ones, net-enhancing tumor. Age, sex, performance status (PS and type of operation were also included in the multivariate analysis. MGMT was assessed for promoter methylation with Multiplex Ligation-dependent Probe Amplification (MLPA, for RNA expression with real time PCR, and for protein expression with immunohistochemistry in a total of 44 cases with available histologic material. Results In the multivariate analysis a negative impact was shown for pre-radiochemotherapy net-enhancing tumor on the overall survival (OS (p = 0.023 and for preoperative necrosis on progression-free survival (PFS (p = 0.030. Furthermore, the multivariate analysis confirmed the importance of PS in PFS and OS of patients. MGMT promoter methylation was observed in 13/23 (43.5% evaluable tumors; complete methylation was observed in 3/13 methylated tumors only. High rate of MGMT protein positivity (> 20% positive neoplastic nuclei was inversely associated with pre-operative tumor necrosis (p = 0.021. Conclusions Our findings implicate that volumetric parameters may have a significant role in

  10. Eight years clinical observation on effect of taking calcium combined with milk on the elderly BMD%牛奶与钙剂对老年人骨密度作用的8年临床观察

    Institute of Scientific and Technical Information of China (English)

    赵亮; 冯佩明; 黄敬

    2009-01-01

    Objective To explore the effect on BMD of the elderly by taking calcium combined with milk. Methods After examining L3BMD of retired employee of the Affiliated Hospital of Chengde Medical College with QCT, we selected L3BMD lower 82 persons (male 35, female 47) from them as participants, they were divided into treatment group (n=43, male 18, female 25) and control group (n=39, male 17, female 22) based on their will, participants in treatment group took 250~500 ml fresh milk and calcium (600 mg~1200 mg) including vitamin D3(125 IU~300 IU) every day, participant in control group didnt take neither of milk and calcium, the observation lasted 96 months. During the process of observation, L3BMD of participants were examined at the 0th month, the 6th month, the 30th month, 96th month. The other examinations including liver function, kidney function, blood serum calcium and urine calcium were taken. And liver, gallbladder, kidney were examined through B mode ultrasound at the same time. In addition, we visited participants to know their idea about treatment. Results (1) Comparing with oneself, the L3 BMD of all participants was getting lower and lower along with age, the control group lowered even more than the treatment group. (2) Comparing L3BMD of control group with L3 BMD of cure group, from the first stage to the third stage, i.e. the 0th month, the 6th month and the 30th month in the process of observation, L3BMD of control group was lower than cure group, but had no statistical significance (P>0.05), at the fourth stage, i.e. the 96th month, L3BMD of control group was more lower than cure group, and showed statistical significance (P0.05).②两组间(观察组与对照组)分4个时间段成组比较L3BMD值,前3个时间段,对照组比观察组降低,但无明显差异(P>0.05),观察至第4个时间段(96个月)时,男女性对照组L3BMD比观察组明显降低,差异有显著性(P<0.05).结论 老年人长期饮用牛奶与含维生素D钙剂,能有

  11. The Relationship Between Biomechanics Agents and BMD of Female Osteoporosis Patient%生物力学因素与女性骨质疏松症病人骨密度的关系

    Institute of Scientific and Technical Information of China (English)

    聂伟志; 石关桐

    2002-01-01

    目的:分析女性骨质疏松症病人骨密度与体重、体成分、肌力等的关系,从生物力学角度探讨骨质疏松症的危险因素.方法:以本院骨质疏松专科就诊的女性病人为研究对象,先用DEXA测定股骨颈骨密度,随即用MES测定身高、体重、全身脂肪含量、下肢肌肉分布系数、下肢最大肌力.从上述受试者中选取股骨颈骨密度T值低于同性别年轻人骨密度峰值-2SD者,诊为OP病人.用Excel软件分析骨密度与体重、体重指数、全身脂肪含量、下肢肌肉分布、下肢最大肌力的相关系数.结果:股骨颈骨密度的影响因素依次是:体重>下肢最大肌力>下肢肌肉分布系数>体重指数>脂肪含量,其中脂肪含量与股骨颈骨密度的相关性无统计学意义(P>0.05).结论:体重、体重指数、肌肉分布、最大肌力是股骨颈骨密度的影响因素.体成分中主要是肌肉对骨密度起决定作用;肌肉对骨密度的影响主要是通过动态负荷即肌力引起,其次才是静态负荷即肌肉本身产生的重力引起.%Objective:To study the the relationship between Biomechanics agents and bone mineral density(BMD) of female osteoporosis patients with MES(muscle evaluation system),and discuss the risk factors of biomechanics for osteoporosis.Methods:select female patients from osteoporosis department of our hospital,assay the femur neck BMD with DEXA(dual energy X-ray absorptiometry),then assay the body weight,the fat content of total body,the muscle distribution coefficient of lower limb,the maximum muscle strength.Assay body height(BH),calculate body mass index(BMI).Among the above objects,select the ones whose T-score of femur neck BMD under -2SD(standard difference) as osteoporosis patients.Analyse the relationship between the BW,BMI,the fat content of total body,the muscle distribution coefficient of lower limb,the maximum muscle strength and the BMD with Excel software.Results:From maximum to

  12. DIFFERENTIAL ANALYSIS OF VOLUMETRIC STRAINS IN POROUS MATERIALS IN TERMS OF WATER FREEZING

    Directory of Open Access Journals (Sweden)

    Rusin Z.

    2013-06-01

    Full Text Available The paper presents the differential analysis of volumetric strain (DAVS. The method allows measurements of volumetric deformations of capillary-porous materials caused by water-ice phase change. The VSE indicator (volumetric strain effect, which under certain conditions can be interpreted as the minimum degree of phase change of water contained in the material pores, is proposed. The test results (DAVS for three materials with diversified microstructure: clinker brick, calcium-silicate brick and Portland cement mortar were compared with the test results for pore characteristics obtained with the mercury intrusion porosimetry.

  13. Is there a role for the use of volumetric cone beam computed tomography in periodontics?

    Science.gov (United States)

    du Bois, A H; Kardachi, B; Bartold, P M

    2012-03-01

    Volumetric computed cone beam tomography offers a number of significant advantages over conventional intraoral and extraoral panoramic radiography, as well as computed tomography. To date, periodontal diagnosis has relied heavily on the assessment of both intraoral radiographs and extraoral panoramic radiographs. With emerging technology in radiology there has been considerable interest in the role that volumetric cone beam computed tomography might play in periodontal diagnostics. This narrative reviews the current evidence and considers whether there is a role for volumetric cone beam computed tomography in periodontics.

  14. Parkinson's disease: diagnostic utility of volumetric imaging

    Energy Technology Data Exchange (ETDEWEB)

    Lin, Wei-Che; Chen, Meng-Hsiang [Kaohsiung Chang Gung Memorial Hospital and Chang Gung University College of Medicine, Department of Diagnostic Radiology, Kaohsiung (China); Chou, Kun-Hsien [National Yang-Ming University, Brain Research Center, Taipei (China); Lee, Pei-Lin [National Yang-Ming University, Department of Biomedical Imaging and Radiological Sciences, Taipei (China); Tsai, Nai-Wen; Lu, Cheng-Hsien [Kaohsiung Chang Gung Memorial Hospital and Chang Gung University College of Medicine, Department of Neurology, Kaohsiung (China); Chen, Hsiu-Ling [Kaohsiung Chang Gung Memorial Hospital and Chang Gung University College of Medicine, Department of Diagnostic Radiology, Kaohsiung (China); National Yang-Ming University, Department of Biomedical Imaging and Radiological Sciences, Taipei (China); Hsu, Ai-Ling [National Taiwan University, Institute of Biomedical Electronics and Bioinformatics, Taipei (China); Huang, Yung-Cheng [Kaohsiung Chang Gung Memorial Hospital and Chang Gung University College of Medicine, Department of Nuclear Medicine, Kaohsiung (China); Lin, Ching-Po [National Yang-Ming University, Brain Research Center, Taipei (China); National Yang-Ming University, Department of Biomedical Imaging and Radiological Sciences, Taipei (China)

    2017-04-15

    This paper aims to examine the effectiveness of structural imaging as an aid in the diagnosis of Parkinson's disease (PD). High-resolution T{sub 1}-weighted magnetic resonance imaging was performed in 72 patients with idiopathic PD (mean age, 61.08 years) and 73 healthy subjects (mean age, 58.96 years). The whole brain was parcellated into 95 regions of interest using composite anatomical atlases, and region volumes were calculated. Three diagnostic classifiers were constructed using binary multiple logistic regression modeling: the (i) basal ganglion prior classifier, (ii) data-driven classifier, and (iii) basal ganglion prior/data-driven hybrid classifier. Leave-one-out cross validation was used to unbiasedly evaluate the predictive accuracy of imaging features. Pearson's correlation analysis was further performed to correlate outcome measurement using the best PD classifier with disease severity. Smaller volume in susceptible regions is diagnostic for Parkinson's disease. Compared with the other two classifiers, the basal ganglion prior/data-driven hybrid classifier had the highest diagnostic reliability with a sensitivity of 74%, specificity of 75%, and accuracy of 74%. Furthermore, outcome measurement using this classifier was associated with disease severity. Brain structural volumetric analysis with multiple logistic regression modeling can be a complementary tool for diagnosing PD. (orig.)

  15. Volumetric Analysis of Regional Cerebral Development in Preterm Children

    Science.gov (United States)

    Kesler, Shelli R.; Ment, Laura R.; Vohr, Betty; Pajot, Sarah K.; Schneider, Karen C.; Katz, Karol H.; Ebbitt, Timothy B.; Duncan, Charles C.; Makuch, Robert W.; Reiss, Allan L.

    2011-01-01

    Preterm birth is frequently associated with both neuropathologic and cognitive sequelae. This study examined cortical lobe, subcortical, and lateral ventricle development in association with perinatal variables and cognitive outcome. High-resolution volumetric magnetic resonance imaging scans were acquired and quantified using advanced image processing techniques. Seventy-three preterm and 33 term control children ages 7.3-11.4 years were included in the study. Results indicated disproportionately enlarged parietal and frontal gray matter, occipital horn, and ventricular body, as well as reduced temporal and subcortical gray volumes in preterm children compared with control subjects. Birth weight was negatively correlated with parietal and frontal gray, as well as occipital horn volumes. Intraventricular hemorrhage was associated with reduced subcortical gray matter. Ventricular cerebrospinal fluid was negatively correlated with subcortical gray matter volumes but not with white matter volumes. Maternal education was the strongest predictor of cognitive function in the preterm group. Preterm birth appears to be associated with disorganized cortical development, possibly involving disrupted synaptic pruning and neural migration. Lower birth weight and the presence of intraventricular hemorrhage may increase the risk for neuroanatomic abnormality. PMID:15519112

  16. Volumetric microscale particle tracking velocimetry (PTV) in porous media

    Science.gov (United States)

    Guo, Tianqi; Aramideh, Soroush; Ardekani, Arezoo M.; Vlachos, Pavlos P.

    2016-11-01

    The steady-state flow through refractive-index-matched glass bead microchannels is measured using microscopic particle tracking velocimetry (μPTV). A novel technique is developed to volumetrically reconstruct particles from oversampled two-dimensional microscopic images of fluorescent particles. Fast oversampling of the quasi-steady-state flow field in the lateral direction is realized by a nano-positioning piezo stage synchronized with a fast CMOS camera. Experiments at different Reynolds numbers are carried out for flows through a series of both monodispersed and bidispersed glass bead microchannels with various porosities. The obtained velocity fields at pore-scale (on the order of 10 μm) are compared with direct numerical simulations (DNS) conducted in the exact same geometries reconstructed from micro-CT scans of the glass bead microchannels. The developed experimental method would serve as a new approach for exploring the flow physics at pore-scale in porous media, and also provide benchmark measurements for validation of numerical simulations.

  17. Buoyancy Driven Mixing with Continuous Volumetric Energy Deposition

    Science.gov (United States)

    Wachtor, Adam J.; Jebrail, Farzaneh F.; Dennisen, Nicholas A.; Andrews, Malcolm J.; Gore, Robert A.

    2014-11-01

    An experiment involving a miscible fluid pair is presented which transitioned from a Rayleigh-Taylor (RT) stable to RT unstable configuration through continuous volumetric energy deposition (VED) by microwave radiation. Initially a light, low microwave absorbing fluid rested above a heavier, more absorbing fluid. The alignment of the density gradient with gravity made the system stable, and the Atwood number (At) for the initial setup was approximately -0.12. Exposing the fluid pair to microwave radiation preferentially heated the bottom fluid, and caused its density to drop due to thermal expansion. As heating of the bottom fluid continued, the At varied from negative to positive, and after the system passed through the neutral stability point, At = 0, buoyancy driven mixing ensued. Continuous VED caused the At to continue increasing and further drive the mixing process. Successful VED mixing required careful design of the fluid pair used in the experiment. Therefore, fluid selection is discussed, along with challenges and limitations of data collection using the experimental microwave facility. Experimental and model predictions of the neutral stability point, and onset of buoyancy driven mixing, are compared, and differences with classical, constant At RT driven turbulence are discussed.

  18. FELIX 3D display: an interactive tool for volumetric imaging

    Science.gov (United States)

    Langhans, Knut; Bahr, Detlef; Bezecny, Daniel; Homann, Dennis; Oltmann, Klaas; Oltmann, Krischan; Guill, Christian; Rieper, Elisabeth; Ardey, Goetz

    2002-05-01

    The FELIX 3D display belongs to the class of volumetric displays using the swept volume technique. It is designed to display images created by standard CAD applications, which can be easily imported and interactively transformed in real-time by the FELIX control software. The images are drawn on a spinning screen by acousto-optic, galvanometric or polygon mirror deflection units with integrated lasers and a color mixer. The modular design of the display enables the user to operate with several equal or different projection units in parallel and to use appropriate screens for the specific purpose. The FELIX 3D display is a compact, light, extensible and easy to transport system. It mainly consists of inexpensive standard, off-the-shelf components for an easy implementation. This setup makes it a powerful and flexible tool to keep track with the rapid technological progress of today. Potential applications include imaging in the fields of entertainment, air traffic control, medical imaging, computer aided design as well as scientific data visualization.

  19. Toward a Philosophy and Theory of Volumetric Nonthermal Processing.

    Science.gov (United States)

    Sastry, Sudhir K

    2016-06-01

    Nonthermal processes for food preservation have been under intensive investigation for about the past quarter century, with varying degrees of success. We focus this discussion on two volumetrically acting nonthermal processes, high pressure processing (HPP) and pulsed electric fields (PEF), with emphasis on scientific understanding of each, and the research questions that need to be addressed for each to be more successful in the future. We discuss the character or "philosophy" of food preservation, with a question about the nature of the kill step(s), and the sensing challenges that need to be addressed. For HPP, key questions and needs center around whether its nonthermal effectiveness can be increased by increased pressures or pulsing, the theoretical treatment of rates of reaction as influenced by pressure, the assumption of uniform pressure distribution, and the need for (and difficulties involved in) in-situ measurement. For PEF, the questions include the rationale for pulsing, difficulties involved in continuous flow treatment chambers, the difference between electroporation theory and experimental observations, and the difficulties involved in in-situ measurement and monitoring of electric field distribution.

  20. Optical artefact characterization and correction in volumetric scintillation dosimetry

    Science.gov (United States)

    Robertson, Daniel; Hui, Cheukkai; Archambault, Louis; Mohan, Radhe; Beddar, Sam

    2014-01-01

    The goals of this study were (1) to characterize the optical artefacts affecting measurement accuracy in a volumetric liquid scintillator detector, and (2) to develop methods to correct for these artefacts. The optical artefacts addressed were photon scattering, refraction, camera perspective, vignetting, lens distortion, the lens point spread function, stray radiation, and noise in the camera. These artefacts were evaluated by theoretical and experimental means, and specific correction strategies were developed for each artefact. The effectiveness of the correction methods was evaluated by comparing raw and corrected images of the scintillation light from proton pencil beams against validated Monte Carlo calculations. Blurring due to the lens and refraction at the scintillator tank-air interface were found to have the largest effect on the measured light distribution, and lens aberrations and vignetting were important primarily at the image edges. Photon scatter in the scintillator was not found to be a significant source of artefacts. The correction methods effectively mitigated the artefacts, increasing the average gamma analysis pass rate from 66% to 98% for gamma criteria of 2% dose difference and 2 mm distance to agreement. We conclude that optical artefacts cause clinically meaningful errors in the measured light distribution, and we have demonstrated effective strategies for correcting these optical artefacts.

  1. An MRI-based semiautomated volumetric quantification of hip osteonecrosis

    Energy Technology Data Exchange (ETDEWEB)

    Malizos, K.N.; Siafakas, M.S.; Karachalios, T.S. [Dept. of Orthopaedics, Univ. of Thessalia, Larissa (Greece); Fotiadis, D.I. [Dept. of Computer Science, Univ. of Ioannina (Greece); Soucacos, P.N. [Dept. of Orthopaedic Surgery, Univ. of Ioannina (Greece)

    2001-12-01

    Objective: To objectively and precisely define the spatial distribution of osteonecrosis and to investigate the influence of various factors including etiology. Design: A volumetric method is presented to describe the size and spatial distribution of necrotic lesions of the femoral head, using MRI scans. The technique is based on the definition of an equivalent sphere model for the femoral head. Patients: The gender, age, number of hips involved, disease duration, pain intensity, limping disability and etiology were correlated with the distribution of the pathologic bone. Seventy-nine patients with 122 hips affected by osteonecrosis were evaluated. Results: The lesion size ranged from 7% to 73% of the sphere equivalent. The lateral octants presented considerable variability, ranging from wide lateral lesions extending beyond the lip of the acetabulum, to narrow medial lesions, leaving a lateral supporting pillar of intact bone. Patients with sickle cell disease and steroid administration presented the largest lesions. The extent of the posterior superior medial octant involvement correlated with the symptom intensity, a younger age and male gender. Conclusion: The methodology presented here has proven a reliable and straightforward imaging tool for precise assessment of necrotic lesions. It also enables us to target accurately the drilling and grafting procedures. (orig.)

  2. Illustration-inspired depth enhanced volumetric medical visualization.

    Science.gov (United States)

    Svakhine, Nikolai A; Ebert, David S; Andrews, William M

    2009-01-01

    Volume illustration can be used to provide insight into source data from CT/MRI scanners in much the same way as medical illustration depicts the important details of anatomical structures. As such, proven techniques used in medical illustration should be transferable to volume illustration, providing scientists with new tools to visualize their data. In recent years, a number of techniques have been developed to enhance the rendering pipeline and create illustrative effects similar to the ones found in medical textbooks and surgery manuals. Such effects usually highlight important features of the subject while subjugating its context and providing depth cues for correct perception. Inspired by traditional visual and line-drawing techniques found in medical illustration, we have developed a collection of fast algorithms for more effective emphasis/de-emphasis of data as well as conveyance of spatial relationships. Our techniques utilize effective outlining techniques and selective depth enhancement to provide perceptual cues of object importance as well as spatial relationships in volumetric datasets. Moreover, we have used illustration principles to effectively combine and adapt basic techniques so that they work together to provide consistent visual information and a uniform style.

  3. Connectivity network measures predict volumetric atrophy in mild cognitive impairment.

    Science.gov (United States)

    Nir, Talia M; Jahanshad, Neda; Toga, Arthur W; Bernstein, Matt A; Jack, Clifford R; Weiner, Michael W; Thompson, Paul M

    2015-01-01

    Alzheimer's disease (AD) is characterized by cortical atrophy and disrupted anatomic connectivity, and leads to abnormal interactions between neural systems. Diffusion-weighted imaging (DWI) and graph theory can be used to evaluate major brain networks and detect signs of a breakdown in network connectivity. In a longitudinal study using both DWI and standard magnetic resonance imaging (MRI), we assessed baseline white-matter connectivity patterns in 30 subjects with mild cognitive impairment (MCI, mean age 71.8 ± 7.5 years, 18 males and 12 females) from the Alzheimer's Disease Neuroimaging Initiative. Using both standard MRI-based cortical parcellations and whole-brain tractography, we computed baseline connectivity maps from which we calculated global "small-world" architecture measures, including mean clustering coefficient and characteristic path length. We evaluated whether these baseline network measures predicted future volumetric brain atrophy in MCI subjects, who are at risk for developing AD, as determined by 3-dimensional Jacobian "expansion factor maps" between baseline and 6-month follow-up anatomic scans. This study suggests that DWI-based network measures may be a novel predictor of AD progression.

  4. Femoral head osteonecrosis: Volumetric MRI assessment and outcome

    Energy Technology Data Exchange (ETDEWEB)

    Bassounas, Athanasios E. [Department of Medical Physics, School of Medicine, University of Ioannina, GR 451 10 Ioannina (Greece); Karantanas, Apostolos H. [Department of Radiology, School of Medicine, University of Crete, Heraklion, GR 711 10 (Greece); Fotiadis, Dimitrios I. [Unit of Medical Technology and Intelligent Information Systems, Department of Computer Science, University of Ioannina and Biomedical Research Institute-FORTH, GR 451 10 Ioannina (Greece); Malizos, Konstantinos N. [Orthopaedic Department, Medical School, University of Thessalia, GR 412 22 Larissa (Greece)]. E-mail: kmalizos@otenet.gr

    2007-07-15

    Effective treatment of femoral head osteonecrosis (FHON) requires early diagnosis and accurate assessment of the disease severity. The ability to predict in the early stages the risk of collapse is important for selecting a joint salvage procedure. The aim of the present study was to evaluate the outcome in patients treated with vascularized fibular grafts in relation to preoperative MR imaging volumetry. We studied 58 patients (87 hips) with FHON. A semi-automated octant-based lesion measurement method, previously described, was performed on the T1-w MR images. The mean time of postoperative follow-up was 7.8 years. Sixty-three hips were successful and 24 failed and converted to total hip arthroplasty within a period of 2-4 years after the initial operation. The rate of failures for hips of male patients was higher than in female patients. The mean lesion size was 28% of the sphere equivalent of the femoral head, 24 {+-} 12% for the successful hips and 37 {+-} 9% for the failed (p < 0.001). The most affected octants were antero-supero-medial (58 {+-} 26%) and postero-supero-medial (54 {+-} 31%). All but postero-infero-medial and postero-infero-lateral octants, showed statistically significant differences in the lesion size between patients with successful and failed hips. In conclusion, the volumetric analysis of preoperative MRI provides useful information with regard to a successful outcome in patients treated with vascularized fibular grafts.

  5. Three-dimensional volumetric quantification of fat loss following cryolipolysis.

    Science.gov (United States)

    Garibyan, Lilit; Sipprell, William H; Jalian, H Ray; Sakamoto, Fernanda H; Avram, Mathew; Anderson, R Rox

    2014-02-01

    Cryolipolysis is a noninvasive and well-tolerated treatment for reduction of localized subcutaneous fat. Although several studies demonstrate the safety and efficacy of this procedure, volumetric fat reduction from this treatment has not been quantified. This prospective study investigated the change in volume of fat after cryolipolysis treatment using three-dimensional (3D) photography. A prospective study of subjects treated with cryolipolysis on the flank (love handle) was performed at Massachusetts General Hospital. Volume measurements were performed with a Canfield Scientific Vectra three-dimensional camera and software to evaluate the amount of post procedure volume change. Clinical outcomes were assessed with caliper measurements, subject surveys, and blinded physician assessment of photographs. Eleven subjects were enrolled in this study. Each subject underwent a single cycle of cryolipolysis to one flank. The untreated flank served as an internal control. The follow-up time after treatment was 2 months. The mean amount of calculated absolute fat volume loss using 3D photography from baseline to 2 months follow-up visit was 56.2 ± 25.6 from the treatment site and 16.6 ± 17.6 cc from the control (P fat removal methodology that on average leads to 39.6 cc of fat loss of the treated flank at 2 months after a single treatment cycle. © 2013 Wiley Periodicals, Inc.

  6. Cortical thickness and brain volumetric analysis in body dysmorphic disorder.

    Science.gov (United States)

    Madsen, Sarah K; Zai, Alex; Pirnia, Tara; Arienzo, Donatello; Zhan, Liang; Moody, Teena D; Thompson, Paul M; Feusner, Jamie D

    2015-04-30

    Individuals with body dysmorphic disorder (BDD) suffer from preoccupations with perceived defects in physical appearance, causing severe distress and disability. Although BDD affects 1-2% of the population, the neurobiology is not understood. Discrepant results in previous volumetric studies may be due to small sample sizes, and no study has investigated cortical thickness in BDD. The current study is the largest neuroimaging analysis of BDD. Participants included 49 medication-free, right-handed individuals with DSM-IV BDD and 44 healthy controls matched by age, sex, and education. Using high-resolution T1-weighted magnetic resonance imaging, we computed vertex-wise gray matter (GM) thickness on the cortical surface and GM volume using voxel-based morphometry. We also computed volumes in cortical and subcortical regions of interest. In addition to group comparisons, we investigated associations with symptom severity, insight, and anxiety within the BDD group. In BDD, greater anxiety was significantly associated with thinner GM in the left superior temporal cortex and greater GM volume in the right caudate nucleus. There were no significant differences in cortical thickness, GM volume, or volumes in regions of interest between BDD and control subjects. Subtle associations with clinical symptoms may characterize brain morphometric patterns in BDD, rather than large group differences in brain structure. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  7. Region-of-interest volumetric visual hull refinement

    KAUST Repository

    Knoblauch, Daniel

    2010-01-01

    This paper introduces a region-of-interest visual hull refinement technique, based on flexible voxel grids for volumetric visual hull reconstructions. Region-of-interest refinement is based on a multipass process, beginning with a focussed visual hull reconstruction, resulting in a first 3D approximation of the target, followed by a region-of-interest estimation, tasked with identifying features of interest, which in turn are used to locally refine the voxel grid and extract a higher-resolution surface representation for those regions. This approach is illustrated for the reconstruction of avatars for use in tele-immersion environments, where head and hand regions are of higher interest. To allow reproducability and direct comparison a publicly available data set for human visual hull reconstruction is used. This paper shows that region-of-interest reconstruction of the target is faster and visually comparable to higher resolution focused visual hull reconstructions. This approach reduces the amount of data generated through the reconstruction, allowing faster post processing, as rendering or networking of the surface voxels. Reconstruction speeds support smooth interactions between the avatar and the virtual environment, while the improved resolution of its facial region and hands creates a higher-degree of immersion and potentially impacts the perception of body language, facial expressions and eye-to-eye contact. Copyright © 2010 by the Association for Computing Machinery, Inc.

  8. A volumetric flow sensor for automotive injection systems

    Science.gov (United States)

    Schmid, U.; Krötz, G.; Schmitt-Landsiedel, D.

    2008-04-01

    For further optimization of the automotive power train of diesel engines, advanced combustion processes require a highly flexible injection system, provided e.g. by the common rail (CR) injection technique. In the past, the feasibility to implement injection nozzle volumetric flow sensors based on the thermo-resistive measurement principle has been demonstrated up to injection pressures of 135 MPa (1350 bar). To evaluate the transient behaviour of the system-integrated flow sensors as well as an injection amount indicator used as a reference method, hydraulic simulations on the system level are performed for a CR injection system. Experimentally determined injection timings were found to be in good agreement with calculated values, especially for the novel sensing element which is directly implemented into the hydraulic system. For the first time pressure oscillations occurring after termination of the injection pulse, predicted theoretically, could be verified directly in the nozzle. In addition, the injected amount of fuel is monitored with the highest resolution ever reported in the literature.

  9. Dairy food intake, peripheral bone structure, and muscle mass in elderly ambulatory women.

    Science.gov (United States)

    Radavelli-Bagatini, Simone; Zhu, Kun; Lewis, Joshua R; Prince, Richard L

    2014-07-01

    Previous studies suggest that dairy intake may be associated with reduced bone and muscle loss with aging, but there are limited data in the very old. We evaluated the association between intake of dairy foods and peripheral bone structure and muscle mass in 564 elderly women aged 80 to 92 (mean 84.7) years, who were participants of the Calcium Intake Fracture Outcome Study/CAIFOS Aged Extension Study (CAIFOS/CARES) cohort and attended the 10-year follow-up. Assessments included dairy consumption (milk, yogurt, and cheese) by a validated food frequency questionnaire, 15% tibia bone mass, area and volumetric bone mineral density (vBMD) by peripheral quantitative computed tomography (pQCT), and appendicular bone and skeletal muscle mass by dual-energy X-ray absorptiometry (DXA). Women were categorized according to tertiles of dairy intake: first tertile (≤ 1.5 servings/d), second tertile (1.5 to 2.2 servings/d) and third tertile (≥ 2.2 servings/d). Controlling for confounding factors, pQCT assessment at the 15% tibia showed that compared with those in the first tertile of dairy intake, women in the third tertile had 5.7% greater total bone mass (p = 0.005), principally because of an increase in cortical and subcortical bone mass (5.9%, p = 0.050), resulting in a 6.2% increase in total vBMD (p = 0.013). Trabecular but not cortical and subcortical vBMD was also higher (7.8%, p = 0.044). DXA assessment showed that women in the third tertile of dairy intake had greater appendicular bone mass (7.1%, p = 0.007) and skeletal muscle mass (3.3%, p = 0.014) compared with tertile 1. The associations with bone measures were dependent on dairy protein and calcium intakes, whereas the association with appendicular muscle mass was not totally dependent on dairy protein intake. Our results suggest a positive association of dairy intake with appendicular bone mineralization and muscle mass in elderly women. Because many fractures in this age group are of the appendicular skeleton

  10. On the Uncertain Future of the Volumetric 3D Display Paradigm

    Science.gov (United States)

    Blundell, Barry G.

    2017-06-01

    Volumetric displays permit electronically processed images to be depicted within a transparent physical volume and enable a range of cues to depth to be inherently associated with image content. Further, images can be viewed directly by multiple simultaneous observers who are able to change vantage positions in a natural way. On the basis of research to date, we assume that the technologies needed to implement useful volumetric displays able to support translucent image formation are available. Consequently, in this paper we review aspects of the volumetric paradigm and identify important issues which have, to date, precluded their successful commercialization. Potentially advantageous characteristics are outlined and demonstrate that significant research is still needed in order to overcome barriers which continue to hamper the effective exploitation of this display modality. Given the recent resurgence of interest in developing commercially viable general purpose volumetric systems, this discussion is of particular relevance.

  11. Volumetric study of the olfactory bulb in patients with chronic rhinonasal sinusitis using MRI

    Directory of Open Access Journals (Sweden)

    Reda A. Alarabawy

    2016-06-01

    Conclusions: MRI with volumetric analysis is a useful tool in assessment of the olfactory bulb volume in patients with olfactory loss and appears to be of help in assessment of the degree of recovery in patients after sinus surgery.

  12. Inkjet printing-based volumetric display projecting multiple full-colour 2D patterns

    Science.gov (United States)

    Hirayama, Ryuji; Suzuki, Tomotaka; Shimobaba, Tomoyoshi; Shiraki, Atsushi; Naruse, Makoto; Nakayama, Hirotaka; Kakue, Takashi; Ito, Tomoyoshi

    2017-04-01

    In this study, a method to construct a full-colour volumetric display is presented using a commercially available inkjet printer. Photoreactive luminescence materials are minutely and automatically printed as the volume elements, and volumetric displays are constructed with high resolution using easy-to-fabricate means that exploit inkjet printing technologies. The results experimentally demonstrate the first prototype of an inkjet printing-based volumetric display composed of multiple layers of transparent films that yield a full-colour three-dimensional (3D) image. Moreover, we propose a design algorithm with 3D structures that provide multiple different 2D full-colour patterns when viewed from different directions and experimentally demonstrate prototypes. It is considered that these types of 3D volumetric structures and their fabrication methods based on widely deployed existing printing technologies can be utilised as novel information display devices and systems, including digital signage, media art, entertainment and security.

  13. Effect of consolidation pressure on volumetric composition and stiffness of unidirectional flax fibre composites

    DEFF Research Database (Denmark)

    Aslan, Mustafa; Mehmood, S.; Madsen, Bo

    2013-01-01

    Unidirectional flax/polyethylene terephthalate composites are manufactured by filament winding, followed by compression moulding with low and high consolidation pressure, and with variable flax fibre content. The experimental data of volumetric composition and tensile stiffness are analysed with ...

  14. Mechanical properties, volumetric shrinkage and depth of cure of short fiber-reinforced resin composite.

    Science.gov (United States)

    Tsujimoto, Akimasa; Barkmeier, Wayne W; Takamizawa, Toshiki; Latta, Mark A; Miyazaki, Masashi

    2016-01-01

    The mechanical properties, volumetric shrinkage and depth of cure of a short fiber-reinforced resin composite (SFRC) were investigated in this study and compared to both a bulk fill resin composite (BFRC) and conventional glass/ceramic-filled resin composite (CGRC). Fracture toughness, flexural properties, volumetric shrinkage and depth of cure of the SFRC, BFRC and CGRC were measured. SFRC had significantly higher fracture toughness than BFRCs and CGRCs. The flexural properties of SFRC were comparable with BFRCs and CGRCs. SFRC showed significantly lower volumetric shrinkage than the other tested resin composites. The depth of cure of the SFRC was similar to BFRCs and higher than CGRCs. The data from this laboratory investigation suggests that SFRC exhibits improvements in fracture toughness, volumetric shrinkage and depth of cure when compared with CGRC, but depth of cure of SFRC was similar to BFRC.

  15. Review of prospects and challenges of eye tracking in volumetric imaging.

    Science.gov (United States)

    Venjakob, Antje C; Mello-Thoms, Claudia R

    2016-01-01

    While eye tracking research in conventional radiography has flourished over the past decades, the number of eye tracking studies that looked at multislice images lags behind. A possible reason for the lack of studies in this area might be that the eye tracking methodology used in the context of conventional radiography cannot be applied one-on-one to volumetric imaging material. Challenges associated with eye tracking in volumetric imaging are particularly associated with the selection of stimulus material, the detection of events in the eye tracking data, the calculation of meaningful eye tracking parameters, and the reporting of abnormalities. However, all of these challenges can be addressed in the design of the experiment. If this is done, eye tracking studies using volumetric imaging material offer almost unlimited opportunity for perception research and are highly relevant as the number of volumetric images that are acquired and interpreted is rising.

  16. Planning strategies in volumetric modulated are therapy for breast.

    Science.gov (United States)

    Giorgia, Nicolini; Antonella, Fogliata; Alessandro, Clivio; Eugenio, Vanetti; Luca, Cozzi

    2011-07-01

    In breast radiotherapy with intensity modulation, it is a well established practice to extend the dose fluence outside the limit of the body contour to account for small changes in size and position of the target and the rest of the tissues due to respiration or to possible oedema. A simple approach is not applicable with RapidArc volumetric modulated are therapy not being based on a fixed field fluence delivery. In this study, a viable technical strategy to account for this need is presented. RapidArc (RA) plans for six breast cancer patients (three right and three left cases), were optimized (PRO version III) on the original CT data set (0) and on an alternative CT (E) generated with an artificial expansion (and assignment of soft-tissue equivalent HU) of 10 mm of the body in the breast region and of the PTV contours toward the external direction. Final dose calculations for the two set of plans were performed on the same original CT data set O, normalizing the dose prescription (50 Gy) to the target mean. In this way, two treatment plans on the same CT set O for each patient were obtained: the no action plan (OO) and the alternative plan based on an expanded optimization (EO). Fixing MU, these two plans were then recomputed on the expanded CT data set and on an intermediate one (with expansion = 5 mm), to mimic, possible changes in size due to edema during treatment or residual displacements due to breathing not properly controlled. Aim of the study was to quantify the robustness of this planning strategy on dose distributions when either the OO or the EO strategies were adopted. For all the combinations, a DVH analysis of all involved structures is reported. I. The two optimization approaches gave comparable dose distributions on the original CT data set. II. When plans were evaluated on the expanded CTs (mimicking the presence of edema), the EO approach showed improved target coverage if compared to OO: on CT_10 mm, Dv = 98% [%]= 92.5 +/- 0.9 and 68.5 +/- 3

  17. Planning strategies in volumetric modulated arc therapy for breast.

    Science.gov (United States)

    Nicolini, Giorgia; Fogliata, Antonella; Clivio, Alessandro; Vanetti, Eugenio; Cozzi, Luca

    2011-07-01

    In breast radiotherapy with intensity modulation, it is a well established practice to extend the dose fluence outside the limit of the body contour to account for small changes in size and position of the target and the rest of the tissues due to respiration or to possible oedema. A simple approach is not applicable with RapidArc volumetric modulated arc therapy not being based on a fixed field fluence delivery. In this study, a viable technical strategy to account for this need is presented. RapidArc (RA) plans for six breast cancer patients (three right and three left cases), were optimized (PRO version III) on the original CT data set (O) and on an alternative CT (E) generated with an artificial expansion (and assignment of soft-tissue equivalent HU) of 10 mm of the body in the breast region and of the PTV contours toward the external direction. Final dose calculations for the two set of plans were performed on the same original CT data set O, normalizing the dose prescription (50 Gy) to the target mean. In this way, two treatment plans on the same CT set O for each patient were obtained: the no action plan (OO) and the alternative plan based on an expanded optimization (EO). Fixing MU, these two plans were then recomputed on the expanded CT data set and on an intermediate one (with expansion = 5 mm), to mimic, possible changes in size due to edema during treatment or residual displacements due to breathing not properly controlled. Aim of the study was to quantify the robustness of this planning strategy on dose distributions when either the OO or the EO strategies were adopted. For all the combinations, a DVH analysis of all involved structures is reported. I. The two optimization approaches gave comparable dose distributions on the original CT data set. II. When plans were evaluated on the expanded CTs (mimicking the presence of edema), the EO approach showed improved target coverage if compared to OO: on CT_10 mm, DV = 98% [%] = 92.5 ± 0

  18. Volumetric Properties of the Mixture Tetrachloromethane CCl4 + CHCl3 Trichloromethane (VMSD1212, LB4576_V)

    Science.gov (United States)

    Cibulka, I.; Fontaine, J.-C.; Sosnkowska-Kehiaian, K.; Kehiaian, H. V.

    This document is part of Subvolume C 'Binary Liquid Systems of Nonelectrolytes III' of Volume 26 'Heats of Mixing, Vapor-Liquid Equilibrium, and Volumetric Properties of Mixtures and Solutions' of Landolt-Börnstein Group IV 'Physical Chemistry'. It contains the Chapter 'Volumetric Properties of the Mixture Tetrachloromethane CCl4 + CHCl3 Trichloromethane (VMSD1212, LB4576_V)' providing data by calculation of molar excess volume from low-pressure density measurements at variable mole fraction and constant temperature.

  19. Determination of ferrous iron in rock and mineral samples by three volumetric methods

    OpenAIRE

    Saikkonen, R.J.; Rautiainen, I.A.

    1993-01-01

    Ferrous iron was determined by three volumetric methods in 13 in-house reference rock samples and in 31 international geological reference samples. The methods used were Amonette & Scott' s oxidimetric method, Wilson's oxidimetric method and Pratt's method. The results for FeO by these volumetric methods in 13 in-house rock samples were compared to the results obtained in other analytical laboratories in Finland. The results for FeO in the international samples were compared with published da...

  20. FEMUR SHAPE RECOVERY FROM VOLUMETRIC IMAGES USING 3-D DEFORMABLE MODELS

    Institute of Scientific and Technical Information of China (English)

    2000-01-01

    A new scheme for femur shape recovery from volumetric images using deformable models was proposed. First, prior 3-D deformable femur models are created as templates using point distribution models technology. Second, active contour models are employed to segment the magnetic resonance imaging (MRI) volumetric images of the tibial and femoral joints and the deformable models are initialized based on the segmentation results. Finally, the objective function is minimized to give the optimal results constraining the surface of shapes.

  1. Understanding Volumetric and Gravimetric Hydrogen Adsorption Trade-off in Metal-Organic Frameworks.

    Science.gov (United States)

    Gómez-Gualdrón, Diego A; Wang, Timothy C; García-Holley, Paula; Sawelewa, Ruth M; Argueta, Edwin; Snurr, Randall Q; Hupp, Joseph T; Yildirim, Taner; Farha, Omar K

    2017-04-07

    Metal-organic frameworks (MOFs) are porous crystalline materials that are promising for adsorption-based, on-board storage of hydrogen in fuel-cell vehicles. Volumetric and gravimetric hydrogen capacities are the key factors that determine the size and weight of the MOF-filled tank required to store a certain amount of hydrogen for reasonable driving range. Therefore, they must be optimized so the tank is neither too large nor too heavy. Because the goals of maximizing MOF volumetric and gravimetric hydrogen adsorption loadings individually are incompatible, an in-depth understanding of the trade-off between MOF volumetric and gravimetric loadings is necessary to achieve the best compromise between these properties. Here we study, both experimentally and computationally, the trade-off between volumetric and gravimetric cryo-adsorbed hydrogen deliverable capacity by taking an isoreticular series of highly stable zirconium MOFs, NU-1101, NU-1102, and NU-1103 as a case study. These MOFs were studied under recently proposed operating conditions: 77 K/100 bar →160 K/5 bar. We found the difference between highest and lowest measured deliverable capacity in the MOF series to be ca. 40% gravimetrically, but only ca. 10% volumetrically. From our molecular simulation results, we found hydrogen "monolayer" adsorption to be proportional to the surface area, whereas hydrogen "pore filling" adsorption is proportional to the pore volume. Thus, we found that the higher variability in gravimetric deliverable capacity in contrast to the volumetric capacity, occurs due to the proportional relation between gravimetric surface area and pore volume in the NU-110x series in contrast to the inverse relation between volumetric surface area and void fraction. Additionally, we find better correlations with geometric surface areas than with BET areas. NU-1101 presents the highest measured volumetric performance with 46.6 g/L (9.1 wt %), whereas NU-1103 presents the highest gravimetric one

  2. Optimization of volumetric breast density estimation in digital mammograms.

    Science.gov (United States)

    Holland, Katharina; Gubern-Mérida, Albert; Mann, Ritse M; Karssemeijer, Nico

    2017-05-07

    Fibroglandular tissue volume and percent density can be estimated in unprocessed mammograms using a physics-based method, which relies on an internal reference value representing the projection of fat only. However, pixels representing fat only may not be present in dense breasts, causing an underestimation of density measurements. In this work, we investigate alternative approaches for obtaining a tissue reference value to improve density estimations, particularly in dense breasts. Two of three investigated reference values (F1, F2) are percentiles of the pixel value distribution in the breast interior (the contact area of breast and compression paddle). F1 is determined in a small breast interior, which minimizes the risk that peripheral pixels are included in the measurement at the cost of increasing the chance that no proper reference can be found. F2 is obtained using a larger breast interior. The new approach which is developed for very dense breasts does not require the presence of a fatty tissue region. As reference region we select the densest region in the mammogram and assume that this represents a projection of entirely dense tissue embedded between the subcutaneous fatty tissue layers. By measuring the thickness of the fat layers a reference (F3) can be computed. To obtain accurate breast density estimates irrespective of breast composition we investigated a combination of the results of the three reference values. We collected 202 pairs of MRI's and digital mammograms from 119 women. We compared the percent dense volume estimates based on both modalities and calculated Pearson's correlation coefficients. With the references F1-F3 we found respectively a correlation of [Formula: see text], [Formula: see text] and [Formula: see text]. Best results were obtained with the combination of the density estimations ([Formula: see text]). Results show that better volumetric density estimates can be obtained with the hybrid method, in particular for dense

  3. Semiautomatic segmentation of liver metastases on volumetric CT images

    Energy Technology Data Exchange (ETDEWEB)

    Yan, Jiayong [Department of Biomedical Engineering, Shanghai University of Medicine & Health Sciences, 101 Yingkou Road, Yang Pu District, Shanghai 200093 (China); Schwartz, Lawrence H.; Zhao, Binsheng, E-mail: bz2166@cumc.columbia.edu [Department of Radiology, Columbia University Medical Center, 630 West 168th Street, New York, New York 10032 (United States)

    2015-11-15

    Purpose: Accurate segmentation and quantification of liver metastases on CT images are critical to surgery/radiation treatment planning and therapy response assessment. To date, there are no reliable methods to perform such segmentation automatically. In this work, the authors present a method for semiautomatic delineation of liver metastases on contrast-enhanced volumetric CT images. Methods: The first step is to manually place a seed region-of-interest (ROI) in the lesion on an image. This ROI will (1) serve as an internal marker and (2) assist in automatically identifying an external marker. With these two markers, lesion contour on the image can be accurately delineated using traditional watershed transformation. Density information will then be extracted from the segmented 2D lesion and help determine the 3D connected object that is a candidate of the lesion volume. The authors have developed a robust strategy to automatically determine internal and external markers for marker-controlled watershed segmentation. By manually placing a seed region-of-interest in the lesion to be delineated on a reference image, the method can automatically determine dual threshold values to approximately separate the lesion from its surrounding structures and refine the thresholds from the segmented lesion for the accurate segmentation of the lesion volume. This method was applied to 69 liver metastases (1.1–10.3 cm in diameter) from a total of 15 patients. An independent radiologist manually delineated all lesions and the resultant lesion volumes served as the “gold standard” for validation of the method’s accuracy. Results: The algorithm received a median overlap, overestimation ratio, and underestimation ratio of 82.3%, 6.0%, and 11.5%, respectively, and a median average boundary distance of 1.2 mm. Conclusions: Preliminary results have shown that volumes of liver metastases on contrast-enhanced CT images can be accurately estimated by a semiautomatic segmentation

  4. Blockwise conjugate gradient methods for image reconstruction in volumetric CT.

    Science.gov (United States)

    Qiu, W; Titley-Peloquin, D; Soleimani, M

    2012-11-01

    Cone beam computed tomography (CBCT) enables volumetric image reconstruction from 2D projection data and plays an important role in image guided radiation therapy (IGRT). Filtered back projection is still the most frequently used algorithm in applications. The algorithm discretizes the scanning process (forward projection) into a system of linear equations, which must then be solved to recover images from measured projection data. The conjugate gradients (CG) algorithm and its variants can be used to solve (possibly regularized) linear systems of equations Ax=b and linear least squares problems minx∥b-Ax∥2, especially when the matrix A is very large and sparse. Their applications can be found in a general CT context, but in tomography problems (e.g. CBCT reconstruction) they have not widely been used. Hence, CBCT reconstruction using the CG-type algorithm LSQR was implemented and studied in this paper. In CBCT reconstruction, the main computational challenge is that the matrix A usually is very large, and storing it in full requires an amount of memory well beyond the reach of commodity computers. Because of these memory capacity constraints, only a small fraction of the weighting matrix A is typically used, leading to a poor reconstruction. In this paper, to overcome this difficulty, the matrix A is partitioned and stored blockwise, and blockwise matrix-vector multiplications are implemented within LSQR. This implementation allows us to use the full weighting matrix A for CBCT reconstruction without further enhancing computer standards. Tikhonov regularization can also be implemented in this fashion, and can produce significant improvement in the reconstructed images.

  5. Application of AAPM TG 119 to volumetric arc therapy (VMAT).

    Science.gov (United States)

    Mynampati, Dinesh Kumar; Yaparpalvi, Ravindra; Hong, Linda; Kuo, Hsiang-Chi; Mah, Dennis

    2012-09-06

    The purpose of this study was to create AAPM TG 119 benchmark plans for volumetric arc therapy (VMAT) and to compare VMAT plans with IMRT plan data. AAPM TG 119 proposes a set of test clinical cases for testing the accuracy of IMRT planning and delivery system. For these test cases, we generated two treatment plans, the first plan using 7-9 static dMLC IMRT fields and a second plan utilizing one- or two-arc VMAT technique. Dose optimization and calculations performed using 6 MV photons and Eclipse treatment planning system. Dose prescription and planning objectives were set according to the TG 119 goals. Plans were scored based on TG 119 planning objectives. Treatment plans were compared using conformity index (CI) for reference dose and homogeneity index (HI) (for D(5)-D(95)). For test cases prostate, head-and-neck, C-shape and multitarget prescription dose are 75.6 Gy, 50.4 Gy, 50 Gy and 50 Gy, respectively. VMAT dose distributions were comparable to dMLC IMRT plans. Our planning results matched TG 119 planning results. For treatment plans studied, conformity indices ranged from 1.05-1.23 (IMRT) and 1.04-1.23 (VMAT). Homogeneity indices ranged from 4.6%-11.0% (IMRT) and 4.6%-10.5% (VMAT). The ratio of total monitor units necessary for dMLC IMRT to that of VMAT was in the range of 1.1-2.0. AAPM TG 119 test cases are useful to generate VMAT benchmark plans. At preclinical implementation stage, plan comparison of VMAT and IMRT plans of AAPM TG 119 test case allowed us to understand basic capabilities of VMAT technique.

  6. Mammographic density estimation with automated volumetric breast density measurement.

    Science.gov (United States)

    Ko, Su Yeon; Kim, Eun-Kyung; Kim, Min Jung; Moon, Hee Jung

    2014-01-01

    To compare automated volumetric breast density measurement (VBDM) with radiologists' evaluations based on the Breast Imaging Reporting and Data System (BI-RADS), and to identify the factors associated with technical failure of VBDM. In this study, 1129 women aged 19-82 years who underwent mammography from December 2011 to January 2012 were included. Breast density evaluations by radiologists based on BI-RADS and by VBDM (Volpara Version 1.5.1) were compared. The agreement in interpreting breast density between radiologists and VBDM was determined based on four density grades (D1, D2, D3, and D4) and a binary classification of fatty (D1-2) vs. dense (D3-4) breast using kappa statistics. The association between technical failure of VBDM and patient age, total breast volume, fibroglandular tissue volume, history of partial mastectomy, the frequency of mass > 3 cm, and breast density was analyzed. The agreement between breast density evaluations by radiologists and VBDM was fair (k value = 0.26) when the four density grades (D1/D2/D3/D4) were used and moderate (k value = 0.47) for the binary classification (D1-2/D3-4). Twenty-seven women (2.4%) showed failure of VBDM. Small total breast volume, history of partial mastectomy, and high breast density were significantly associated with technical failure of VBDM (p = 0.001 to 0.015). There is fair or moderate agreement in breast density evaluation between radiologists and VBDM. Technical failure of VBDM may be related to small total breast volume, a history of partial mastectomy, and high breast density.

  7. Measurement and analysis of BMD of the lumbar vertebrae using QCT in patients with ankylosing spondylitis%强直性脊柱炎患者腰椎定量CT骨密度测定及分析

    Institute of Scientific and Technical Information of China (English)

    丁明; 魏健; 薛峰; 钱学江; 韩爱强

    2013-01-01

    目的 测定强直性脊柱炎患者腰椎骨密度(BMD),分析骨量变化相关因素,指导治疗.方法选取强直性脊柱炎患者66例为实验组,26例健康查体者为对照组,登记一般资料及病程、ESR、CRP、BASFI及HLA-B27等指标,应用定量CT测定腰1-5椎体BMD,进行两组间BMD比较及危险因素相关分析.结果 实验组腰椎皮质骨及松质骨BMD均显著低于对照组(269.1±39.8 vs 308.2±49.3 mg/mL,140.8±18.6 vs 190.1±15.7 mg/mL,P<0.01),实验组腰椎松质骨BMD丢失百分率显著高于皮质骨(25.9%±10.3% vs 12.7%±13.2%,P<0.01),实验组骨量减少和骨质疏松发生率分别为45.5%和39.4%.病程及骶髂关节破坏程度与骨密度负相关,身高、体重、BMI、BASFI、ESR和/或CRP是否升高及HLA-B27阳性与否均与骨密度无相关性.结论 强直性脊柱炎患者腰椎BMD显著降低,骨质疏松发生率高,应早期评估BMD,及时应用生物制剂等防治骨量丢失.%Objective To measure the bone mineral density ( BMD ) in patients with ankylosing spondylitis ( AS ), to analyze the relevant factors of bone mass changes, and to guide the clinical treatment. Methods Sixty-six patients with AS were selected and divided into study group. Twenty-six subjects received healthy examination were divided into control group. General information, duration of disease, and indexes including ESR, CRP, Bath AS functional index ( BASFI ), and HLA-B27 were all recorded. BMD of the lumbar vertebrae ( L1 - 5 ) was measured using quantitative computed tomography ( QCT ). The correlation between BMD and the risk factors was analyzed. Results BMD of both lumbar cortical bone and spongy bone in study group was significantly lower than that in control group ( 269. 1 ± 39. 8 vs 308. 2 ± 49. 3 mg/ml, 140. 8 ± 18. 6 vs 190. 1 ± 15. 7 mg/ml, P <0. 01, respectively ). The loss of BMD of the lumbar spongy bone was significantly higher than that of the lumbar cortical bone in study group ( 25. 9 ± 10. 3% vs

  8. Computational Analysis of Artificial Gravity as a Possible Countermeasure to Spaceflight Induced Bone Loss

    Science.gov (United States)

    Mulugeta, L.; Werner, C. R.; Pennline, J. A.

    2015-01-01

    During exploration class missions, such as to asteroids and Mars, astronauts will be exposed to reduced gravity for extended periods. Data has shown that astronauts lose bone mass at a rate of 1% to 2% a month in microgravity, particularly in lower extremities such as the proximal femur. Exercise countermeasures have not completely eliminated bone loss from long duration spaceflight missions, which leaves astronauts susceptible to early onset osteoporosis and greater risk of fracture. Introduction of the Advanced Resistive Exercise Device and other large exercise devices on the International Space Station (ISS), coupled with improved nutrition, has further minimized bone loss. However, unlike the ISS, exploration vehicles will have very limited volume and power available to accommodate such capabilities. Therefore, novel concepts like artificial gravity systems are being explored as a means to provide sufficient load stimulus to the musculoskeletal system to mitigate bone changes that may lead to early onset osteoporosis and increased risk of fracture. Currently, there is minimal data available to drive further research and development efforts to appropriately explore such options. Computational modeling can be leveraged to gain insight on the level of osteoprotection that may be achieved using artificial gravity produced by a spinning spacecraft or centrifuge. With this in mind, NASA's Digital Astronaut Project (DAP) has developed a bone remodeling model that has been validated for predicting volumetric bone mineral density (vBMD) changes of trabecular and cortical bone both for gravitational unloading condition and the equivalent of 1g daily load stimulus. Using this model, it is possible to simulate vBMD changes in trabecular and cortical bone under different gravity conditions. In this presentation, we will discuss our preliminary findings regarding if and how artificial gravity may be used to mitigate spaceflight induced bone loss.

  9. Distal radius plate of CFR-PEEK has minimal effect compared to titanium plates on bone parameters in high-resolution peripheral quantitative computed tomography: a pilot study.

    Science.gov (United States)

    de Jong, Joost J A; Lataster, Arno; van Rietbergen, Bert; Arts, Jacobus J; Geusens, Piet P; van den Bergh, Joop P W; Willems, Paul C

    2017-02-27

    Carbon-fiber-reinforced poly-ether-ether-ketone (CFR-PEEK) has superior radiolucency compared to other orthopedic implant materials, e.g. titanium or stainless steel, thus allowing metal-artifact-free postoperative monitoring by computed tomography (CT). Recently, high-resolution peripheral quantitative CT (HRpQCT) proved to be a promising technique to monitor the recovery of volumetric bone mineral density (vBMD), micro-architecture and biomechanical parameters in stable conservatively treated distal radius fractures. When using HRpQCT to monitor unstable distal radius fractures that require volar distal radius plating for fixation, radiolucent CFR-PEEK plates may be a better alternative to currently used titanium plates to allow for reliable assessment. In this pilot study, we assessed the effect of a volar distal radius plate made from CFR-PEEK on bone parameters obtained from HRpQCT in comparison to two titanium plates. Plates were instrumented in separate cadaveric human fore-arms (n = 3). After instrumentation and after removal of the plates duplicate HRpQCT scans were made of the region covered by the plate. HRpQCT images were visually checked for artifacts. vBMD, micro-architectural and biomechanical parameters were calculated, and compared between the uninstrumented and instrumented radii. No visible image artifacts were observed in the CFR-PEEK plate instrumented radius, and errors in bone parameters ranged from -3.2 to 2.6%. In the radii instrumented with the titanium plates, severe image artifacts were observed and errors in bone parameters ranged between -30.2 and 67.0%. We recommend using CFR-PEEK plates in longitudinal in vivo studies that monitor the healing process of unstable distal radius fractures treated operatively by plating or bone graft ingrowth.

  10. Fetal and neonatal exposure to the endocrine disruptor, methoxychlor, reduces lean body mass and bone mineral density and increases cortical porosity.

    Science.gov (United States)

    Fagnant, Heather S; Uzumcu, Mehmet; Buckendahl, Patricia; Dunn, Michael G; Shupper, Peter; Shapses, Sue A

    2014-12-01

    Endogenous estrogen has beneficial effects on mature bone and negatively affects the developing skeleton, whereas the effect of environmental estrogens is not known. Methoxychlor (MXC) is a synthetic estrogen known as a persistent organochlorine and used as a pesticide. Methoxychlor and its metabolites display estrogenic, anti-estrogenic and anti-androgenic activity and may therefore influence bone. Fifty-eight male fetal and neonatal rats were exposed to either: a negative control (DMSO), 0.020, 100 mg/kg MXC, or 1 mg/kg β-estradiol-3-benzoate (EB; positive control). Rats were treated daily for 11 days, from embryonic day 19 to postnatal day (PND) 7 or for 4 days during the postnatal period (PND 0-7). All rats were analyzed at PND-84. Total body, femur, spine, and tibia areal bone mineral density (BMD) and content (BMC), lean body mass (LBM) and fat were measured by dual energy X-ray absorptiometry. Bone geometry and volumetric (v) BMD were measured using micro-computed tomography and biomechanical properties using three-point bending were assessed. Rats exposed to EB or MXC (at either the high and/or low dose), independent of exposure interval showed lower body weight, LBM, tibia and femur BMD and length, and total body BMD and BMC than DMSO control group (p ≤ 0.05). Methoxychlor and EB exposure increased cortical porosity compared to DMSO controls. Trabecular vBMD, number and separation, and cortical polar moment of inertia and cross-sectional area were lower due to EB exposure compared to control (p < 0.05). Early MXC exposure compromises cortical porosity and bone size at maturity, and could ultimately increase the risk of fracture with aging.

  11. Dual-energy X-ray absorptiometry, peripheral quantitative computed tomography, and micro-computed tomography techniques are discordant for bone density and geometry measurements in the guinea pig.

    Science.gov (United States)

    Mak, Ivy L; DeGuire, Jason R; Lavery, Paula; Agellon, Sherry; Weiler, Hope A

    2016-05-01

    This study aims to examine agreement among bone mineral content (BMC) and density (BMD) estimates obtained using dual-energy X-ray absorptiometry (DXA), peripheral quantitative computed tomography (pQCT), and micro-computed tomography (μCT) against high-resolution μCT and bone ash of the guinea pig femur. Middle-aged (n = 40, 86 weeks) male guinea pigs underwent in vivo followed by ex vivo DXA (Hologic QDR 4500A) scanning for intact and excised femur BMC and areal density. To assess bone architecture and strength, excised femurs were scanned on pQCT (Stratec XCT 2000L) as well as on two μCT scanners (LaTheta LCT-200; Skyscan 1174), followed by three-point bending test. Reproducibility was determined using triplicate scans; and agreement assessed using Bland-Altman plots with reference methods being high-resolution μCT (Skyscan) for BMD and bone ashing for BMC. All techniques showed satisfactory ex vivo precision (CV 0.05-4.3 %). However, bias compared to the reference method was highest (207.5 %) in trabecular bone volume fraction (BV/TV) measured by LaTheta, and unacceptable in most total femur and cortical bone measurements. Volumetric BMD (vBMD) and BV/TV derived by LaTheta and pQCT at the distal metaphysis were biased from the Skyscan by an average of 49.3 and 207.5 %, respectively. Variability of vBMD, BV/TV and cross-sectional area at the diaphysis ranged from -5.5 to 30.8 %. LaTheta best quantified total femur BMC with an upper bias of 3.3 %. The observed differences among imaging techniques can be attributable to inherent dissimilarity in construction design, calibration, segmentation and scanning resolution used. These bone imaging tools are precise but are not comparable, at least when assessing guinea pig bones.

  12. A Technique for Generating Volumetric Cine MRI (VC-MRI)

    Science.gov (United States)

    Harris, Wendy; Ren, Lei; Cai, Jing; Zhang, You; Chang, Zheng; Yin, Fang-Fang

    2016-01-01

    Purpose To develop a technique to generate on-board volumetric-cine MRI (VC-MRI) using patient prior images, motion modeling and on-board 2D-cine MRI. Methods One phase of a 4D-MRI acquired during patient simulation is used as patient prior images. 3 major respiratory deformation patterns of the patient are extracted from 4D-MRI based on principal-component-analysis. The on-board VC-MRI at any instant is considered as a deformation of the prior MRI. The deformation field is represented as a linear combination of the 3 major deformation patterns. The coefficients of the deformation patterns are solved by the data fidelity constraint using the acquired on-board single 2D-cine MRI. The method was evaluated using both XCAT simulation of lung cancer patients and MRI data from four real liver cancer patients. The accuracy of the estimated VC-MRI was quantitatively evaluated using Volume-Percent-Difference(VPD), Center-of-Mass-Shift(COMS), and target tracking errors. Effects of acquisition orientation, region-of-interest(ROI) selection, patient breathing pattern change and noise on the estimation accuracy were also evaluated. Results Image subtraction of ground-truth with estimated on-board VC-MRI shows fewer differences than image subtraction of ground-truth with prior image. Agreement between profiles in the estimated and ground-truth VC-MRI was achieved with less than 6% error for both XCAT and patient data. Among all XCAT scenarios, the VPD between ground-truth and estimated lesion volumes was on average 8.43±1.52% and the COMS was on average 0.93±0.58mm across all time-steps for estimation based on the ROI region in the sagittal cine images. Matching to ROI in the sagittal view achieved better accuracy when there was substantial breathing pattern change. The technique was robust against noise levels up to SNR=20. For patient data, average tracking errors were less than 2 mm in all directions for all patients. Conclusions Preliminary studies demonstrated the

  13. A Technique for Generating Volumetric Cine-Magnetic Resonance Imaging.

    Science.gov (United States)

    Harris, Wendy; Ren, Lei; Cai, Jing; Zhang, You; Chang, Zheng; Yin, Fang-Fang

    2016-06-01

    The purpose of this study was to develop a techique to generate on-board volumetric cine-magnetic resonance imaging (VC-MRI) using patient prior images, motion modeling, and on-board 2-dimensional cine MRI. One phase of a 4-dimensional MRI acquired during patient simulation is used as patient prior images. Three major respiratory deformation patterns of the patient are extracted from 4-dimensional MRI based on principal-component analysis. The on-board VC-MRI at any instant is considered as a deformation of the prior MRI. The deformation field is represented as a linear combination of the 3 major deformation patterns. The coefficients of the deformation patterns are solved by the data fidelity constraint using the acquired on-board single 2-dimensional cine MRI. The method was evaluated using both digital extended-cardiac torso (XCAT) simulation of lung cancer patients and MRI data from 4 real liver cancer patients. The accuracy of the estimated VC-MRI was quantitatively evaluated using volume-percent-difference (VPD), center-of-mass-shift (COMS), and target tracking errors. Effects of acquisition orientation, region-of-interest (ROI) selection, patient breathing pattern change, and noise on the estimation accuracy were also evaluated. Image subtraction of ground-truth with estimated on-board VC-MRI shows fewer differences than image subtraction of ground-truth with prior image. Agreement between normalized profiles in the estimated and ground-truth VC-MRI was achieved with less than 6% error for both XCAT and patient data. Among all XCAT scenarios, the VPD between ground-truth and estimated lesion volumes was, on average, 8.43 ± 1.52% and the COMS was, on average, 0.93 ± 0.58 mm across all time steps for estimation based on the ROI region in the sagittal cine images. Matching to ROI in the sagittal view achieved better accuracy when there was substantial breathing pattern change. The technique was robust against noise levels up to SNR = 20. For

  14. Volumetric particle image velocimetry with a single plenoptic camera

    Science.gov (United States)

    Fahringer, Timothy W.; Lynch, Kyle P.; Thurow, Brian S.

    2015-11-01

    A novel three-dimensional (3D), three-component (3C) particle image velocimetry (PIV) technique based on volume illumination and light field imaging with a single plenoptic camera is described. A plenoptic camera uses a densely packed microlens array mounted near a high resolution image sensor to sample the spatial and angular distribution of light collected by the camera. The multiplicative algebraic reconstruction technique (MART) computed tomography algorithm is used to reconstruct a volumetric intensity field from individual snapshots and a cross-correlation algorithm is used to estimate the velocity field from a pair of reconstructed particle volumes. This work provides an introduction to the basic concepts of light field imaging with a plenoptic camera and describes the unique implementation of MART in the context of plenoptic image data for 3D/3C PIV measurements. Simulations of a plenoptic camera using geometric optics are used to generate synthetic plenoptic particle images, which are subsequently used to estimate the quality of particle volume reconstructions at various particle number densities. 3D reconstructions using this method produce reconstructed particles that are elongated by a factor of approximately 4 along the optical axis of the camera. A simulated 3D Gaussian vortex is used to test the capability of single camera plenoptic PIV to produce a 3D/3C vector field, where it was found that lateral displacements could be measured to approximately 0.2 voxel accuracy in the lateral direction and 1 voxel in the depth direction over a 300× 200× 200 voxel volume. The feasibility of the technique is demonstrated experimentally using a home-built plenoptic camera based on a 16-megapixel interline CCD camera and a 289× 193 array of microlenses and a pulsed Nd:YAG laser. 3D/3C measurements were performed in the wake of a low Reynolds number circular cylinder and compared with measurements made using a conventional 2D/2C PIV system. Overall, single camera

  15. Transient refractory material dissolution by a volumetrically-heated melt

    Energy Technology Data Exchange (ETDEWEB)

    Seiler, Jean Marie, E-mail: jean-marie.seiler@cea.fr [CEA, DEN, DTN, 17 Rue des Martyrs, 38054 Grenoble Cedex 9 (France); Ratel, Gilles [CEA, DEN, DTN, 17 Rue des Martyrs, 38054 Grenoble Cedex 9 (France); Combeau, Hervé [Institut Jean Lamour, UMR 7198, Lorraine University, Ecole des Mines de Nancy, Parc de Saurupt, 54042 Nancy Cedex (France); Gaus-Liu, Xiaoyang; Kretzschmar, Frank; Miassoedov, Alexei [Karlsruhe Institut of Technology, Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen (Germany)

    2014-12-15

    Highlights: • We describe a test investigating ceramic dissolution by a molten non-eutectic melt. • The evolution of the interface temperature between melt and refractory is measured. • A theoretical model describing dissolution kinetics is proposed. • When dissolution stops, interface temperature is the liquidus temperature of the melt. - Abstract: The present work addresses the question of corium–ceramic interaction in a core catcher during a core-melt accident in a nuclear power plant. It provides an original insight into transient aspects concerning dissolution of refractory material by a volumetrically heated pool. An experiment with simulant material (LIVECERAM) is presented. Test results clearly show that dissolution of solid refractory material can occur in a non-eutectic melt at a temperature which is lower than the melting temperature of the refractory material. During the dissolution transient, the interface temperature rises above the liquidus temperature, corresponding to the instantaneous average composition of the melt pool. With constant power dissipation in the melt and external cooling of the core-catcher, a final steady-state situation is reached. Dissolution stops when the heat flux (delivered by the melt to the refractory) can be removed by conduction through the residual thickness of the ceramic, with T{sub interface} = T{sub liquidus} (calculated for the average composition of the final liquid pool). The final steady state corresponds to a uniform pool composition and uniform interface temperature distribution. Convection in the pool is governed by natural thermal convection and the heat flux distribution is therefore similar to what would be obtained for a single component pool. An interpretation of the experiment with two model-based approaches (0D and 1D) is presented. The mass transfer kinetics between the interface and the bulk is controlled by a diffusion sublayer within the boundary layer. During the dissolution transient

  16. Volumetric Forest Change Detection Through Vhr Satellite Imagery

    Science.gov (United States)

    Akca, Devrim; Stylianidis, Efstratios; Smagas, Konstantinos; Hofer, Martin; Poli, Daniela; Gruen, Armin; Sanchez Martin, Victor; Altan, Orhan; Walli, Andreas; Jimeno, Elisa; Garcia, Alejandro

    2016-06-01

    Quick and economical ways of detecting of planimetric and volumetric changes of forest areas are in high demand. A research platform, called FORSAT (A satellite processing platform for high resolution forest assessment), was developed for the extraction of 3D geometric information from VHR (very-high resolution) imagery from satellite optical sensors and automatic change detection. This 3D forest information solution was developed during a Eurostars project. FORSAT includes two main units. The first one is dedicated to the geometric and radiometric processing of satellite optical imagery and 2D/3D information extraction. This includes: image radiometric pre-processing, image and ground point measurement, improvement of geometric sensor orientation, quasiepipolar image generation for stereo measurements, digital surface model (DSM) extraction by using a precise and robust image matching approach specially designed for VHR satellite imagery, generation of orthoimages, and 3D measurements in single images using mono-plotting and in stereo images as well as triplets. FORSAT supports most of the VHR optically imagery commonly used for civil applications: IKONOS, OrbView - 3, SPOT - 5 HRS, SPOT - 5 HRG, QuickBird, GeoEye-1, WorldView-1/2, Pléiades 1A/1B, SPOT 6/7, and sensors of similar type to be expected in the future. The second unit of FORSAT is dedicated to 3D surface comparison for change detection. It allows users to import digital elevation models (DEMs), align them using an advanced 3D surface matching approach and calculate the 3D differences and volume changes between epochs. To this end our 3D surface matching method LS3D is being used. FORSAT is a single source and flexible forest information solution with a very competitive price/quality ratio, allowing expert and non-expert remote sensing users to monitor forests in three and four dimensions from VHR optical imagery for many forest information needs. The capacity and benefits of FORSAT have been tested in

  17. Improving plan quality for prostate volumetric-modulated arc therapy.

    Science.gov (United States)

    Wright, Katrina; Ferrari-Anderson, Janet; Barry, Tamara; Bernard, Anne; Brown, Elizabeth; Lehman, Margot; Pryor, David

    2017-08-04

    We critically evaluated the quality and consistency of volumetric-modulated arc therapy (VMAT) prostate planning at a single institution to quantify objective measures for plan quality and establish clear guidelines for plan evaluation and quality assurance. A retrospective analysis was conducted on 34 plans generated on the Pinnacle(3) version 9.4 and 9.8 treatment planning system to deliver 78 Gy in 39 fractions to the prostate only using VMAT. Data were collected on contoured structure volumes, overlaps and expansions, planning target volume (PTV) and organs at risk volumes and relationship, dose volume histogram, plan conformity, plan homogeneity, low-dose wash, and beam parameters. Standard descriptive statistics were used to describe the data. Despite a standardized planning protocol, we found variability was present in all steps of the planning process. Deviations from protocol contours by radiation oncologists and radiation therapists occurred in 12% and 50% of cases, respectively, and the number of optimization parameters ranged from 12 to 27 (median 17). This contributed to conflicts within the optimization process reflected by the mean composite objective value of 0.07 (range 0.01 to 0.44). Methods used to control low-intermediate dose wash were inconsistent. At the PTV rectum interface, the dose-gradient distance from the 74.1 Gy to 40 Gy isodose ranged from 0.6 cm to 2.0 cm (median 1.0 cm). Increasing collimator angle was associated with a decrease in monitor units and a single full 6 MV arc was sufficient for the majority of plans. A significant relationship was found between clinical target volume-rectum distance and rectal tolerances achieved. A linear relationship was determined between the PTV volume and volume of 40 Gy isodose. Objective values and composite objective values were useful in determining plan quality. Anatomic geometry and overlap of structures has a measurable impact on the plan quality achieved for prostate patients

  18. Semi-automated volumetric analysis of artificial lymph nodes in a phantom study.

    Science.gov (United States)

    Fabel, M; Biederer, J; Jochens, A; Bornemann, L; Soza, G; Heller, M; Bolte, H

    2011-12-01

    Quantification of tumour burden in oncology requires accurate and reproducible image evaluation. The current standard is one-dimensional measurement (e.g. RECIST) with inherent disadvantages. Volumetric analysis is discussed as an alternative for therapy monitoring of lung and liver metastases. The aim of this study was to investigate the accuracy of semi-automated volumetric analysis of artificial lymph node metastases in a phantom study. Fifty artificial lymph nodes were produced in a size range from 10 to 55mm; some of them enhanced using iodine contrast media. All nodules were placed in an artificial chest phantom (artiCHEST®) within different surrounding tissues. MDCT was performed using different collimations (1-5 mm) at varying reconstruction kernels (B20f, B40f, B60f). Volume and RECIST measurements were performed using Oncology Software (Siemens Healthcare, Forchheim, Germany) and were compared to reference volume and diameter by calculating absolute percentage errors. The software performance allowed a robust volumetric analysis in a phantom setting. Unsatisfying segmentation results were frequently found for native nodules within surrounding muscle. The absolute percentage error (APE) for volumetric analysis varied between 0.01 and 225%. No significant differences were seen between different reconstruction kernels. The most unsatisfactory segmentation results occurred in higher slice thickness (4 and 5 mm). Contrast enhanced lymph nodes showed better segmentation results by trend. The semi-automated 3D-volumetric analysis software tool allows a reliable and convenient segmentation of artificial lymph nodes in a phantom setting. Lymph nodes adjacent to tissue of similar density cause segmentation problems. For volumetric analysis of lymph node metastases in clinical routine a slice thickness of ≤3mm and a medium soft reconstruction kernel (e.g. B40f for Siemens scan systems) may be a suitable compromise for semi-automated volumetric analysis. Copyright

  19. The effects of dimensional mould sizes on volumetric shrinkage strain of lateritic soil

    Directory of Open Access Journals (Sweden)

    John Engbonye SANI

    2016-07-01

    Full Text Available Dimensional influences of specimen size on the volumetric shrinkage strain values of a lateritic soil for waste containment system have not been researched upon. Therefore, this paper presents the result of a laboratory study on the volumetric shrinkage strain (VSS of lateritic soil at three different dimensional sizes of mould (split former mould, proctor mould and California bearing ratio mould at three energy levels; British standard light (BSL, West African standard (WAS and British standard heavy (BSH respectively. Compactions were done at different molding water content of -2% to +6% optimum moisture content (OMC. At -2% to +2% molding water content for the split former mould the volumetric shrinkage strain met the requirement of not more than 4% while at +4% and +6% only the WAS and BSH met the requirement. The proctor mould and the CBR mould on the other hand gave a lower value of volumetric shrinkage strain in all compactive effort and the values are lower than the 4% safe VSS suggested by Tay et al., (2001. Based on the VSS values obtained if the CBR mould can be used to model site condition it is recommended for use to simulate site condition for Volumetric shrinkage strain for all molding water content and compactive effort.

  20. Semi-automated volumetric analysis of lymph node metastases during follow-up--initial results.

    Science.gov (United States)

    Fabel, Michael; Bolte, H; von Tengg-Kobligk, H; Bornemann, L; Dicken, V; Delorme, S; Kauczor, H-U; Heller, M; Biederer, J

    2011-04-01

    Quantification of tumour burden in oncology requires accurate and reproducible evaluation. The current standard is RECIST measurement with its inherent disadvantages. Volumetric analysis is an alternative for therapy monitoring. The aim of this study was to evaluate the feasibility of volumetric analysis of lymph node metastases using a software prototype in a follow-up setting. MSCT was performed in 50 patients covering the chest, abdomen and pelvis. A total of 174 suspicious lymph nodes were evaluated by two radiologists regarding short axis diameters and volumetric analysis using semi-automated software. Quality of segmentation, time, maximum diameter and volume were documented. Variability of the derived change rates was computed as the standard deviation of the difference of the obtained respective change rates. The software performance provides robust volumetric analysis. Quality of segmentation was rated acceptable to excellent in 76-79% by each reader. Mean time spent per lesion was 38 s. The variability of change in effective diameters was 10.6%; for change rates of RECIST maximum diameter variability was 27.5%. Semi-automated volumetric analysis allows fast and convenient segmentation of most lymph node metastases. Compared with RECIST the inter-observer-variability in baseline and follow-up is reduced. This should principally allow subtle changes to be subclassified within the RECIST stable range as minor response [-15% to +10%].

  1. VOLUMETRIC MASS TRANSFER COEFFICIENT BETWEEN SLAG AND METAL IN COMBINED BLOWING CONVERTER

    Institute of Scientific and Technical Information of China (English)

    Z.H. Wu; Z.S. Zou; W. Wu

    2005-01-01

    The effects of operation parameters of combined blowing converter on the volumetric mass transfer coefficient between slag and steel are studied with a cold model with water simulating steel, oil simulating slag and benzoic acid as the transferred substance between water and oil. The results show that, with lance level of 2.Im and the top blowing rate of 25000Nm3/h, the volumetric mass transfer coefficient changes most significantly when the bottom blowing rate ranges from 384 to 540Nm3/h. The volumetric mass transfer coefficient reaches its maximum when the lance level is 2. lm, the top blowing rates is 30000Nm3/h, and the bottom blowing rate is 384Nrr3/h with tuyeres located symmetrically at 0.66D of the converter bottom.

  2. Control and design of volumetric composition in pultruded hybrid fibre composites

    DEFF Research Database (Denmark)

    Madsen, Bo; Hashemi, Fariborz; Tahir, Paridah

    2016-01-01

    Hybrid composites consist of two of more fibre phases in a common matrix phase. This is a challenge for the control and design of the volumetric composition and microstructural uniformity of such composites. In the present study, a model is presented for the prediction of the complete volumetric...... composition (i.e. volume fractions of fibres, matrix and porosity) in hybrid fibre composites. The model is based on a constant local fibre volume fraction criterion. Good agreement is found between model predictions and experimental data of pultruded hybrid kenaf/glass fibre composites with variable hybrid...... fibre weight mixing ratios. To demonstrate the suitability of the model, simulations are performed for four different cases of volumetric composition in hybrid kenaf/glass composites....

  3. NDE Technology Development Program for Non-Visual Volumetric Inspection Technology; Sensor Effectiveness Testing Report

    Energy Technology Data Exchange (ETDEWEB)

    Moran, Traci L.; Larche, Michael R.; Denslow, Kayte M.; Glass, Samuel W.

    2017-08-31

    The Pacific Northwest National Laboratory (PNNL) located in Richland, Washington, hosted and administered Sensor Effectiveness Testing that allowed four different participants to demonstrate the NDE volumetric inspection technologies that were previously demonstrated during the Technology Screening session. This document provides a Sensor Effectiveness Testing report for the final part of Phase I of a three-phase NDE Technology Development Program designed to identify and mature a system or set of non-visual volumetric NDE technologies for Hanford DST primary liner bottom inspection. Phase I of the program will baseline the performance of current or emerging non-visual volumetric NDE technologies for their ability to detect and characterize primary liner bottom flaws, and identify candidate technologies for adaptation and maturation for Phase II of the program.

  4. Ultrahigh volumetric capacitance and cyclic stability of fluorine and nitrogen co-doped carbon microspheres

    Science.gov (United States)

    Zhou, Junshuang; Lian, Jie; Hou, Li; Zhang, Junchuan; Gou, Huiyang; Xia, Meirong; Zhao, Yufeng; Strobel, Timothy A.; Tao, Lu; Gao, Faming

    2015-09-01

    Highly porous nanostructures with large surface areas are typically employed for electrical double-layer capacitors to improve gravimetric energy storage capacity; however, high surface area carbon-based electrodes result in poor volumetric capacitance because of the low packing density of porous materials. Here, we demonstrate ultrahigh volumetric capacitance of 521 F cm-3 in aqueous electrolytes for non-porous carbon microsphere electrodes co-doped with fluorine and nitrogen synthesized by low-temperature solvothermal route, rivaling expensive RuO2 or MnO2 pseudo-capacitors. The new electrodes also exhibit excellent cyclic stability without capacitance loss after 10,000 cycles in both acidic and basic electrolytes at a high charge current of 5 A g-1. This work provides a new approach for designing high-performance electrodes with exceptional volumetric capacitance with high mass loadings and charge rates for long-lived electrochemical energy storage systems.

  5. Combination volumetric and gravimetric sorption instrument for high accuracy measurements of methane adsorption

    Science.gov (United States)

    Burress, Jacob; Bethea, Donald; Troub, Brandon

    2017-05-01

    The accurate measurement of adsorbed gas up to high pressures (˜100 bars) is critical for the development of new materials for adsorbed gas storage. The typical Sievert-type volumetric method introduces accumulating errors that can become large at maximum pressures. Alternatively, gravimetric methods employing microbalances require careful buoyancy corrections. In this paper, we present a combination gravimetric and volumetric system for methane sorption measurements on samples between ˜0.5 and 1 g. The gravimetric method described requires no buoyancy corrections. The tandem use of the gravimetric method allows for a check on the highest uncertainty volumetric measurements. The sources and proper calculation of uncertainties are discussed. Results from methane measurements on activated carbon MSC-30 and metal-organic framework HKUST-1 are compared across methods and within the literature.

  6. Single step full volumetric reconstruction optical coherence tomography utilizing compressive sensing

    Science.gov (United States)

    Chen, Luoyang; Liu, Jiansheng; cheng, Jiangtao; Liu, Haitao; Zhou, Hongwen

    2017-03-01

    3D optical coherence tomography imaging (OCT) combined with compressive sensing (CS) has been proved to be an attractive and effective tool in a variety of fields, such as medicine and biology. To achieve high quality imaging while using as less CS sampling rate as possible is the goal of this approach. Here we present an innovative single step fully 3D CS-OCT volumetric image recovery method, in which 3D OCT volumetric image of the object is compressively sampled via our proposed CS coding strategies in all three dimensions while its sparsity is simultaneously taken into consideration in every direction. The object can be directly recovered as the whole volume reconstruction via our advanced full 3D CS reconstruction algorithm. The numerical simulations of a human retina OCT volumetric image reconstruction by our method demonstrate a PSNR of as high as 38dB at a sampling rate of less than 10%.

  7. Seeding optimization for instantaneous volumetric velocimetry. Application to a jet in crossflow

    CERN Document Server

    Cambonie, Tristan

    2014-01-01

    Every volumetric velocimetry measurements based on tracer (particles, bubbles, etc.) detection can be strongly influenced by the optical screening phenomenon. It has to be taken into account when the the statistical properties associated to the performances of the particle detection and tracking algorithms are significantly affected. It leads to a maximum concentration of particles in the images thus limiting the final spatial resolution of the instantaneous three-dimensional three-components (3D3C) velocity fields. A volumetric velocimetry system based on Defocused Digital Particle Image Velocimetry is used to show that above a critical visual concentration of particles in the images, the concentration and accuracy of the final instantaneous raw velocity vector field drop. The critical concentration depends on physical parameters as well as on the processing algorithms. Three distinct regimes are identified. In the first regime, the concentration is well adapted to volumetric velocimetry, the largest concent...

  8. 男性Ⅱ型糖尿病患者骨密度改变及影响因素初探%Changes of BMD in male patients with type Ⅱ diabetes and its affecting factors

    Institute of Scientific and Technical Information of China (English)

    冯晓丽; 孟萍; 黄姝; 袁林贵; 张忠辉

    2001-01-01

    目的 探讨男性Ⅱ型糖尿病(DM2)患者骨密度(BMD)改变及其影响因素。方法 测定59例男性Ⅱ型糖尿病患者及36例健康男性对照者股骨近端(Neck、Troch、Ward三角区)及腰椎(L2~4)正侧位BMD,血钙(Ca)、磷(P)、骨钙素、甲状旁腺素(PTH)、睾酮(T)和尿Ca/Cr、I型胶原羧基末端肽(CTX)/Cr浓度。根据BMD将DM2患者又分为无骨质疏松组(DM-A1)和并发骨质疏松组(DM-A2),测定两组患者的空腹血糖、胰岛素、C肽,餐后血糖、胰岛素以及糖化血红蛋白。结果 DM2组L2~4及Ward三角区的BMD明显低于对照组(P0.05);尿Ca/Cr比对照组高25%,但差异无显著意义(P=0.137)。DM-A2组的体重指数、血T、尿Ca/Cr、餐后血糖和糖化血红蛋白与DM-A1组差异显著(P<0.05)。结论 Ⅱ型糖尿病患者由于骨形成和骨转换率降低而骨密度下降,腰椎侧位的骨密度检查有助于早期诊断骨质疏松。男性患者中体重指数低、血清睾酮浓度低及血糖控制不良者更易并发骨质疏松。%Objective To study the changes of bone mineral density (BMD) andits affecting factors in male patients with type Ⅱ diabetes mellitus(DM2). Methods BMD of lumbar spine and proximal femur, some bone metabolism related biochemical parameters and serum testos-terone(T) in 59 male patients with type Ⅱ diabetes were measured and compared with those in 36 healthy men. According to BMD, DM2 were divided into with (DM-A2)and without osteoporosis (DM-A1)group. Parameters for glucose and mineral metabolism were compared between two groups. Results (1)BMD of lumbar spine and Ward's triangle in diabetic patients were significantly lower than that of the controls, among which lateral lumbar spine was the lowest (P<0.01). (2) In male patients with type Ⅱ diabetes serum osteocalcin was significantly lower than that of the controls (P<0.05) .Urine calcium to creatinine (Ca/Cr) was

  9. Volumetric Concentration Maximum of Cohesive Sediment in Waters: A Numerical Study

    Directory of Open Access Journals (Sweden)

    Jisun Byun

    2014-12-01

    Full Text Available Cohesive sediment has different characteristics compared to non-cohesive sediment. The density and size of a cohesive sediment aggregate (a so-called, floc continuously changes through the flocculation process. The variation of floc size and density can cause a change of volumetric concentration under the condition of constant mass concentration. This study investigates how the volumetric concentration is affected by different conditions such as flow velocity, water depth, and sediment suspension. A previously verified, one-dimensional vertical numerical model is utilized here. The flocculation process is also considered by floc in the growth type flocculation model. Idealized conditions are assumed in this study for the numerical experiments. The simulation results show that the volumetric concentration profile of cohesive sediment is different from the Rouse profile. The volumetric concentration decreases near the bed showing the elevated maximum in the cases of both current and oscillatory flow. The density and size of floc show the minimum and the maximum values near the elevation of volumetric concentration maximum, respectively. This study also shows that the flow velocity and the critical shear stress have significant effects on the elevated maximum of volumetric concentration. As mechanisms of the elevated maximum, the strong turbulence intensity and increased mass concentration are considered because they cause the enhanced flocculation process. This study uses numerical experiments. To the best of our knowledge, no laboratory or field experiments on the elevated maximum have been carried out until now. It is of great necessity to conduct well-controlled laboratory experiments in the near future.

  10. Using pressure and volumetric approaches to estimate CO2 storage capacity in deep saline aquifers

    OpenAIRE

    Thibeau, S.; Bachu, S.; Birkholzer, J.; Holloway, S; Neele, F.P.; Zou, Q

    2014-01-01

    Various approaches are used to evaluate the capacity of saline aquifers to store CO2, resulting in a wide range of capacity estimates for a given aquifer. The two approaches most used are the volumetric “open aquifer” and “closed aquifer” approaches. We present four full-scale aquifer cases, where CO2 storage capacity is evaluated both volumetrically (with “open” and/or “closed” approaches) and through flow modeling. These examples show that the “open aquifer” CO2 storage capacity estimation ...

  11. Effects of volumetric allocation on heave response of semisubmersible in deep sea

    Institute of Scientific and Technical Information of China (English)

    2009-01-01

    The configuration of semisubmersibles consisting of pontoons and columns and their corresponding heave motion response in incident progressive waves are examined. The purpose of the present study is to provide a theoretical approach to estimating the effects of volumetric allocation on natural period and response amplitude operator (RAO) in heave motion. We conclude that the amplitude of heave motion response can be considerably suppressed by appropriately adjusting volumetric allocation so that the natural heave period keeps away from the range of wave energy. The theoretical formulae are found in good agreement with the corresponding computational results by WAMIT.

  12. Volumetric Diffuse Optical Tomography for Small Animals Using a CCD-Camera-Based Imaging System

    Directory of Open Access Journals (Sweden)

    Zi-Jing Lin

    2012-01-01

    Full Text Available We report the feasibility of three-dimensional (3D volumetric diffuse optical tomography for small animal imaging by using a CCD-camera-based imaging system with a newly developed depth compensation algorithm (DCA. Our computer simulations and laboratory phantom studies have demonstrated that the combination of a CCD camera and DCA can significantly improve the accuracy in depth localization and lead to reconstruction of 3D volumetric images. This approach may present great interests for noninvasive 3D localization of an anomaly hidden in tissue, such as a tumor or a stroke lesion, for preclinical small animal models.

  13. DIRECT VOXEL-PROJECTION FOR VOLUMETRIC DATA RENDERING IN MEDICAL IMAGERY

    Institute of Scientific and Technical Information of China (English)

    吕忆松; 陈亚珠; 郭玉红

    2002-01-01

    The volumetric rendering of 3-D medical image data is very effective method for communication about radiological studies to clinicians. Algorithms that produce images with artifacts and inaccuracies are not clinically useful. This paper proposed a direct voxel-projection algorithm to implement volumetric data rendering. Using this algorithm, arbitrary volume rotation, transparent and cutaway views are generated satisfactorily. Compared with the existing raytracing methods, it improves the projection image quality greatly. Some experimental results about real medical CT image data demonstrate the advantages and fidelity of the proposed algorithm.

  14. Correlation Between Liver Volumetric Computed Tomography Results and Measured Liver Weight: A Tool for Preoperative Planning of Liver Transplant

    NARCIS (Netherlands)

    Sonnemans, L.J.; Hol, J.C.; Monshouwer, R.; Prokop, M.; Klein, W.M.

    2016-01-01

    OBJECTIVES: Before liver transplant, it is necessary to know the size of the organ in advance of the procedure. We studied the correlation between liver volumetric computed tomography results and liver weight. MATERIALS AND METHODS: Postmortem volumetric computed tomography was conducted on cadavers

  15. Two-dimensional and volumetric airway changes after bimaxillary surgery for class III malocclusion.

    Science.gov (United States)

    Vaezi, Toraj; Zarch, Seyed Hossein Hosseini; Eshghpour, Majid; Kermani, Hamed

    2017-04-01

    Any change in maxilla and mandible position can alter the upper airway, and any decrease in the upper airway can cause sleep disorders. Thus, it is necessary to assess airway changes after repositioning of the maxilla and mandible during orthognathic surgery. The purpose of this study was to evaluate linear and volumetric changes in the upper airway after bimaxillary surgery to correct class III malocclusion via cone-beam computed tomography (CBCT) and to identify correlations between linear and volumetric changes. This was a prospective cohort study. CBCTs from 10 class III patients were evaluated before surgery and three months after. The Wilcoxon one-sample test was used to evaluate the differences in measurements before and after surgery. Spearman's rank correlation coefficient was used to test the correlation between linear and volumetric changes. The results show that the nasopharyngeal space increased significantly, and that this increase correlated with degree of maxillary advancement. No significant changes were found in volumes before and after surgery. A correlation was found between linear and volumetric oropharyngeal changes. Bimaxillary surgical correction of class III malocclusion did not cause statistically significant changes in the posterior airway space.

  16. MATHEMATICAL MODEL FOR DETERMINATION OF VOLUMETRIC OUTPUT OF LUMBER FROM LOGS, CONTAINING SEVERAL QUALITY AREAS

    Directory of Open Access Journals (Sweden)

    Mikryukova E. V.

    2014-12-01

    Full Text Available In the article we present a method of cutting logs, containing several quality areas. For this method, a mathematical model was developed to determine the volumetric output of lumber, which allows to determine the geometric dimensions of the lumber cut from the different quality areas separated concentric circles, depending on size and quality characteristics of logs

  17. Trapping volumetric measurement by multidetector CT in chronic obstructive pulmonary disease: Effect of CT threshold

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Xiaohua; Yuan, Huishu [Department of Radiology, Peking University Third Hospital, Beijing 100191 (China); Duan, Jianghui [Medical School, Peking University, Beijing 100191 (China); Du, Yipeng; Shen, Ning; He, Bei [Department of Respiration Internal Medicine, Peking University Third Hospital, Beijing 100191 (China)

    2013-08-15

    Purpose: The purpose of this study was to evaluate the effect of various computed tomography (CT) thresholds on trapping volumetric measurements by multidetector CT in chronic obstructive pulmonary disease (COPD).Methods: Twenty-three COPD patients were scanned with a 64-slice CT scanner in both the inspiratory and expiratory phase. CT thresholds of −950 Hu in inspiration and −950 to −890 Hu in expiration were used, after which trapping volumetric measurements were made using computer software. Trapping volume percentage (Vtrap%) under the different CT thresholds in the expiratory phase and below −950 Hu in the inspiratory phase was compared and correlated with lung function.Results: Mean Vtrap% was similar under −930 Hu in the expiratory phase and below −950 Hu in the inspiratory phase, being 13.18 ± 9.66 and 13.95 ± 6.72 (both lungs), respectively; this difference was not significant (P= 0.240). Vtrap% under −950 Hu in the inspiratory phase and below the −950 to −890 Hu threshold in the expiratory phase was moderately negatively correlated with the ratio of forced expiratory volume in one second to forced vital capacity and the measured value of forced expiratory volume in one second as a percentage of the predicted value.Conclusions: Trapping volumetric measurement with multidetector CT is a promising method for the quantification of COPD. It is important to know the effect of various CT thresholds on trapping volumetric measurements.

  18. Transplantation and Perfusion of Microvascular Fragments in a Rodent Model of Volumetric Muscle Loss Injury

    Science.gov (United States)

    2014-07-01

    options are available for the treatment of volumetric muscle loss (VML). An important consideration that needs to be addressed for the development ...fibroblasts that underwent vascular and myogenic development in vitro resulted in substantial tissue perfusion when implanted in an abdominal defect...Greene AS (2000) Development of an implantable muscle stimulator: measurement of stimulated angiogenesis and poststimulus vessel regression

  19. Optical Addressing of Multi-Colour Photochromic Material Mixture for Volumetric Display

    Science.gov (United States)

    Hirayama, Ryuji; Shiraki, Atsushi; Naruse, Makoto; Nakamura, Shinichiro; Nakayama, Hirotaka; Kakue, Takashi; Shimobaba, Tomoyoshi; Ito, Tomoyoshi

    2016-08-01

    This is the first study to demonstrate that colour transformations in the volume of a photochromic material (PM) are induced at the intersections of two control light channels, one controlling PM colouration and the other controlling decolouration. Thus, PM colouration is induced by position selectivity, and therefore, a dynamic volumetric display may be realised using these two control lights. Moreover, a mixture of multiple PM types with different absorption properties exhibits different colours depending on the control light spectrum. Particularly, the spectrum management of the control light allows colour-selective colouration besides position selectivity. Therefore, a PM-based, full-colour volumetric display is realised. We experimentally construct a mixture of two PM types and validate the operating principles of such a volumetric display system. Our system is constructed simply by mixing multiple PM types; therefore, the display hardware structure is extremely simple, and the minimum size of a volume element can be as small as the size of a molecule. Volumetric displays can provide natural three-dimensional (3D) perception; therefore, the potential uses of our system include high-definition 3D visualisation for medical applications, architectural design, human–computer interactions, advertising, and entertainment.

  20. VOLUMETRIC METHOD FOR EVALUATION OF BEACHES VARIABILITY BASED ON GIS-TOOLS

    Directory of Open Access Journals (Sweden)

    V. V. Dolotov

    2015-01-01

    Full Text Available In frame of cadastral beach evaluation the volumetric method of natural variability index is proposed. It base on spatial calculations with Cut-Fill method and volume accounting ofboththe common beach contour and specific areas for the each time.

  1. Using pressure and volumetric approaches to estimate CO2 storage capacity in deep saline aquifers

    NARCIS (Netherlands)

    Thibeau, S.; Bachu, S.; Birkholzer, J.; Holloway, S.; Neele, F.P.; Zou, Q.

    2014-01-01

    Various approaches are used to evaluate the capacity of saline aquifers to store CO2, resulting in a wide range of capacity estimates for a given aquifer. The two approaches most used are the volumetric “open aquifer” and “closed aquifer” approaches. We present four full-scale aquifer cases, where C

  2. Exploration of volumetric cerebral changes, with de micro-MRi, due to psychomotor exercise in mice

    OpenAIRE

    Moës, Florian; Plenevaux, Alain; Becker, Guillaume; Tirelli, Ezio; Lespine, Louis-Ferdinand

    2015-01-01

    It's well know that exercise is good for health .In addition exercise has postive effects on cognition ,neurodegenerative disease and on mood. Some studies show that exercise has effect on brain so the aim of this study is to see if there are volumetric changes due to exercise or not.

  3. Effect of compression paddle tilt correction on volumetric breast density estimation.

    Science.gov (United States)

    Kallenberg, Michiel G J; van Gils, Carla H; Lokate, Mariëtte; den Heeten, Gerard J; Karssemeijer, Nico

    2012-08-21

    For the acquisition of a mammogram, a breast is compressed between a compression paddle and a support table. When compression is applied with a flexible compression paddle, the upper plate may be tilted, which results in variation in breast thickness from the chest wall to the breast margin. Paddle tilt has been recognized as a major problem in volumetric breast density estimation methods. In previous work, we developed a fully automatic method to correct the image for the effect of compression paddle tilt. In this study, we investigated in three experiments the effect of paddle tilt and its correction on volumetric breast density estimation. Results showed that paddle tilt considerably affected accuracy of volumetric breast density estimation, but that effect could be reduced by tilt correction. By applying tilt correction, a significant increase in correspondence between mammographic density estimates and measurements on MRI was established. We argue that in volumetric breast density estimation, tilt correction is both feasible and essential when mammographic images are acquired with a flexible compression paddle.

  4. Follow-up after gamma knife radiosurgery for vestibular schwannomas: volumetric and axial control rates

    NARCIS (Netherlands)

    Timmer, F.C.A.; Hanssens, P.E.; Haren, A.E. van; Overbeeke, J.J. van; Mulder, J.J.S.; Cremers, C.W.R.J.; Graamans, K.

    2011-01-01

    OBJECTIVES/HYPOTHESIS: A prospective long-term follow-up study was conducted to evaluate the results of gamma knife radiosurgery (GKRS) for vestibular schwannoma (VS) patients. Both axial and volumetric measurements are used to determine tumor size during follow-up. STUDY DESIGN: Individual prospect

  5. Empirical correlation of volumetric mass transfer coefficient for a rectangular internal-loop airlift bioreactor

    Science.gov (United States)

    An empirical correlation of volumetric mass transfer coefficient was developed for a pilot scale internal-loop rectangular airlift bioreactor that was designed for biotechnology. The empirical correlation combines classic turbulence theory, Kolmogorov’s isotropic turbulence theory with Higbie’s pen...

  6. Accelerated partial breast irradiation (APBI): are breath-hold and volumetric radiation therapy techniques useful?

    NARCIS (Netherlands)

    Essers, M.; Osman, S.O.; Hol, S.; Donkers, T.; Poortmans, P.M.P.

    2014-01-01

    BACKGROUND: In a selective group of patients accelerated partial breast irradiation (APBI) might be applied after conservative breast surgery to reduce the amount of irradiated healthy tissue. The role of volumetric modulated arc therapy (VMAT) and voluntary moderately deep inspiration breath-hold (

  7. The NCS code of practice for the quality assurance and control for volumetric modulated arc therapy

    NARCIS (Netherlands)

    Mans, Anton; Schuring, Danny; Arends, Mark P.; Vugts, Cornelia A. J. M.; Wolthaus, Jochem W. H.; Lotz, Heidi T.; Admiraal, Marjan; Louwe, Rob J. W.; Ollers, Michel C.; van de Kamer, Jeroen B.

    2016-01-01

    In 2010, the NCS (Netherlands Commission on Radiation Dosimetry) installed a subcommittee to develop guidelines for quality assurance and control for volumetric modulated arc therapy (VMAT) treatments. The report (published in 2015) has been written by Dutch medical physicists and has therefore, ine

  8. Development, Construction, and Operation of a Multisample Volumetric Apparatus for the Study of Gas Adsorption Equilibrium

    Science.gov (United States)

    Ribeiro, Rui P. P. L.; Silva, Ricardo J. S.; Esteves, Isabel A. A. C.; Mota, Jose´ P. B.

    2015-01-01

    The construction of a simple volumetric adsorption apparatus is highlighted. The setup is inexpensive and provides a clear demonstration of gas phase adsorption concepts. The topic is suitable for undergraduate chemistry and chemical engineering students. Moreover, this unit can also provide quantitative data that can be used by young researchers…

  9. Real-time volumetric deformable models for surgery simulation using finite elements and condensation

    DEFF Research Database (Denmark)

    Bro-Nielsen, Morten; Cotin, S.

    1996-01-01

    This paper discusses the application of SD solid volumetric Finite Element models to surgery simulation. In particular it introduces three new ideas for solving the problem of achieving real-time performance for these models. The simulation system we have developed is described and we demonstrate...

  10. Automated volumetric grid generation for finite element modeling of human hand joints

    Energy Technology Data Exchange (ETDEWEB)

    Hollerbach, K.; Underhill, K. [Lawrence Livermore National Lab., CA (United States); Rainsberger, R. [XYZ Scientific Applications, Inc., Livermore, CA (United States)

    1995-02-01

    We are developing techniques for finite element analysis of human joints. These techniques need to provide high quality results rapidly in order to be useful to a physician. The research presented here increases model quality and decreases user input time by automating the volumetric mesh generation step.

  11. Using pressure and volumetric approaches to estimate CO2 storage capacity in deep saline aquifers

    NARCIS (Netherlands)

    Thibeau, S.; Bachu, S.; Birkholzer, J.; Holloway, S.; Neele, F.P.; Zou, Q.

    2014-01-01

    Various approaches are used to evaluate the capacity of saline aquifers to store CO2, resulting in a wide range of capacity estimates for a given aquifer. The two approaches most used are the volumetric “open aquifer” and “closed aquifer” approaches. We present four full-scale aquifer cases, where

  12. Follow-up after gamma knife radiosurgery for vestibular schwannomas: volumetric and axial control rates

    NARCIS (Netherlands)

    Timmer, F.C.A.; Hanssens, P.E.; Haren, A.E. van; Overbeeke, J.J. van; Mulder, J.J.S.; Cremers, C.W.R.J.; Graamans, K.

    2011-01-01

    OBJECTIVES/HYPOTHESIS: A prospective long-term follow-up study was conducted to evaluate the results of gamma knife radiosurgery (GKRS) for vestibular schwannoma (VS) patients. Both axial and volumetric measurements are used to determine tumor size during follow-up. STUDY DESIGN: Individual

  13. Species-specific contribution of volumetric growth and tissue convergence to posterior body elongation in vertebrates.

    Science.gov (United States)

    Steventon, Ben; Duarte, Fernando; Lagadec, Ronan; Mazan, Sylvie; Nicolas, Jean-François; Hirsinger, Estelle

    2016-05-15

    Posterior body elongation is a widespread mechanism propelling the generation of the metazoan body plan. The posterior growth model predicts that a posterior growth zone generates sufficient tissue volume to elongate the posterior body. However, there are energy supply-related differences between vertebrates in the degree to which growth occurs concomitantly with embryogenesis. By applying a multi-scalar morphometric analysis in zebrafish embryos, we show that posterior body elongation is generated by an influx of cells from lateral regions, by convergence-extension of cells as they exit the tailbud, and finally by a late volumetric growth in the spinal cord and notochord. Importantly, the unsegmented region does not generate additional tissue volume. Fibroblast growth factor inhibition blocks tissue convergence rather than volumetric growth, showing that a conserved molecular mechanism can control convergent morphogenesis through different cell behaviours. Finally, via a comparative morphometric analysis in lamprey, dogfish, zebrafish and mouse, we propose that elongation via posterior volumetric growth is linked to increased energy supply and is associated with an overall increase in volumetric growth and elongation. © 2016. Published by The Company of Biologists Ltd.

  14. Cerebrospinal fluid volumetric MRI mapping as a simple measurement for evaluating brain atrophy

    NARCIS (Netherlands)

    De Vis, J B; Zwanenburg, J J|info:eu-repo/dai/nl/290473683; van der Kleij, L A; Spijkerman, J M; Biessels, G J|info:eu-repo/dai/nl/165576367; Hendrikse, J|info:eu-repo/dai/nl/266590268; Petersen, E T

    2016-01-01

    OBJECTIVES: To assess whether volumetric cerebrospinal fluid (CSF) MRI can be used as a surrogate for brain atrophy assessment and to evaluate how the T2 of the CSF relates to brain atrophy. METHODS: Twenty-eight subjects [mean age 64 (sd 2) years] were included; T1-weighted and CSF MRI were perform

  15. Ni foam cathode enables high volumetric H2 production in a microbial electrolysis cell

    NARCIS (Netherlands)

    Jeremiasse, A.W.; Hamelers, H.V.M.; Saakes, M.; Buisman, C.J.N.

    2010-01-01

    Valuable, “green” H2 can be produced with a microbial electrolysis cell (MEC). To achieve a high volumetric production rate of high purity H2, a continuous flow MEC with an anion exchange membrane, a flow through bioanode and a flow through Ni foam cathode was constructed. At an electrical energy in

  16. Semiautomated volumetric response evaluation as an imaging biomarker in superior sulcus tumors

    Energy Technology Data Exchange (ETDEWEB)

    Vos, C.G.; Paul, M.A. [VU University Medical Center, Departments of Surgery, Amsterdam (Netherlands); Dahele, M.; Soernsen de Koste, J.R. van; Senan, S. [VU University Medical Center, Departments of Radiation Oncology, Amsterdam (Netherlands); Bahce, I.; Smit, E.F. [VU University Medical Center, Departments of Pulmonary Diseases, Amsterdam (Netherlands); Thunnissen, E. [VU University Medical Center, Departments of Pathology, Amsterdam (Netherlands); Hartemink, K.J. [VU University Medical Center, Departments of Surgery, Amsterdam (Netherlands); Netherlands Cancer Institute - Antoni van Leeuwenhoek Hospital (NKI-AVL), Department of Surgery, Amsterdam (Netherlands)

    2014-02-15

    Volumetric response to therapy has been suggested as a biomarker for patient-centered outcomes. The primary aim of this pilot study was to investigate whether the volumetric response to induction chemoradiotherapy was associated with pathological complete response (pCR) or survival in patients with superior sulcus tumors managed with trimodality therapy. The secondary aim was to evaluate a semiautomated method for serial volume assessment. In this retrospective study, treatment outcomes were obtained from a departmental database. The tumor was delineated on the computed tomography (CT) scan used for radiotherapy planning, which was typically performed during the first cycle of chemotherapy. These contours were transferred to the post-chemoradiotherapy diagnostic CT scan using deformable image registration (DIR) with/without manual editing. CT scans from 30 eligible patients were analyzed. Median follow-up was 51 months. Neither absolute nor relative reduction in tumor volume following chemoradiotherapy correlated with pCR or 2-year survival. The tumor volumes determined by DIR alone and DIR + manual editing correlated to a high degree (R{sup 2} = 0.99, P < 0.01). Volumetric response to induction chemoradiotherapy was not correlated with pCR or survival in patients with superior sulcus tumors managed with trimodality therapy. DIR-based contour propagation merits further evaluation as a tool for serial volumetric assessment. (orig.)

  17. Toddlers with autism; metabolic, radiologic, and volumetric aspects of brain development

    NARCIS (Netherlands)

    Zeegers, M.

    2006-01-01

    The overall aim of this thesis is to study MR spectroscopic, radiologic, and volumetric brain correlates in very young children with severe developmental disorders; ASD, mental retardation, and language disorder. We wished to examine brain – behaviour relationships in children with ASD at a very you

  18. A hand-held row-column addressed CMUT probe with integrated electronics for volumetric imaging

    DEFF Research Database (Denmark)

    Engholm, Mathias; Christiansen, Thomas Lehrmann; Beers, Christopher;

    2015-01-01

    A 3 MHz, λ / 2-pitch 62+62 channel row-column addressed 2-D CMUT array designed to be mounted in a probe handle and connected to a commercial BK Medical scanner for real-time volumetric imaging is presented. It is mounted and wire-bonded on a flexible PCB, which is connected to two rigid PCBs wit...

  19. Real-time volumetric deformable models for surgery simulation using finite elements and condensation

    DEFF Research Database (Denmark)

    Bro-Nielsen, Morten; Cotin, S.

    1996-01-01

    This paper discusses the application of SD solid volumetric Finite Element models to surgery simulation. In particular it introduces three new ideas for solving the problem of achieving real-time performance for these models. The simulation system we have developed is described and we demonstrate...

  20. Mathematical Model Defining Volumetric Losses of Hydraulic Oil Compression in a Variable Capacity Displacement Pump

    Directory of Open Access Journals (Sweden)

    Paszota Zygmunt

    2015-01-01

    Full Text Available The objective of the work is to develop the capability of evaluating the volumetric losses of hydraulic oil compression in the working chambers of high pressure variable capacity displacement pump. Volumetric losses of oil compression must be determined as functions of the same parameters, which the volumetric losses due to leakage, resulting from the quality of design solution of the pump, are evaluated as dependent on and also as function of the oil aeration coefficient Ɛ. A mathematical model has been developed describing the hydraulic oil compressibility coefficient klc|Δppi;Ɛ;v as a relation to the ratio ΔpPi/pn of indicated increase ΔpPi of pressure in the working chambers and the nominal pressure pn, to the pump capacity coefficient bP, to the oil aeration coefficient  and to the ratio v/vnof oil viscosity v and reference viscosity vn. A mathematical model is presented of volumetric losses qpvc|ΔpPi;bp;;vof hydraulic oil compression in the pump working chambers in the form allowing to use it in the model of power of losses and energy efficiency

  1. Progress in two-dimensional arrays for real-time volumetric imaging.

    Science.gov (United States)

    Light, E D; Davidsen, R E; Fiering, J O; Hruschka, T A; Smith, S W

    1998-01-01

    The design, fabrication, and evaluation of two dimensional array transducers for real-time volumetric imaging are described. The transducers we have previously described operated at frequencies below 3 MHz and were unwieldy to the operator because of the interconnect schemes used in connecting to the transducer handle. Several new transducers have been developed using new connection technology. A 40 x 40 = 1,600 element, 3.5 MHz array was fabricated with 256 transmit and 256 receive elements. A 60 x 60 = 3,600 element 5.0 MHz array was constructed with 248 transmit and 256 receive elements. An 80 x 80 = 6,400 element, 2.5 MHz array was fabricated with 256 transmit and 208receive elements. 2-D transducer arrays were also developed for volumetric scanning in an intra cardiac catheter, a 10 x 10 = 100 element 5.0 MHz forward-looking array and an 11 x 13 = 143 element 5.0 MHz side-scanning array. The-6dB fractional bandwidths for the different arrays varied from 50% to 63%, and the 50 omega insertion loss for all the transducers was about-64 dB. The transducers were used to generate real-time volumetric images in phantoms and in vivo using the Duke University real time volumetric imaging system, which is capable of generating multiple planes at any desired angle and depth within the pyramidal volume.

  2. Effects of Different Reconstruction Parameters on CT Volumetric Measurement 
of Pulmonary Nodules

    Directory of Open Access Journals (Sweden)

    Rongrong YANG

    2012-02-01

    Full Text Available Background and objective It has been proven that volumetric measurements could detect subtle changes in small pulmonary nodules in serial CT scans, and thus may play an important role in the follow-up of indeterminate pulmonary nodules and in differentiating malignant nodules from benign nodules. The current study aims to evaluate the effects of different reconstruction parameters on the volumetric measurements of pulmonary nodules in chest CT scans. Methods Thirty subjects who underwent chest CT scan because of indeterminate pulmonary nodules in General Hospital of Tianjin Medical University from December 2009 to August 2011 were retrospectively analyzed. A total of 52 pulmonary nodules were included, and all CT data were reconstructed using three reconstruction algorithms and three slice thicknesses. The volumetric measurements of the nodules were performed using the advanced lung analysis (ALA software. The effects of the reconstruction algorithms, slice thicknesses, and nodule diameters on the volumetric measurements were assessed using the multivariate analysis of variance for repeated measures, the correlation analysis, and the Bland-Altman method. Results The reconstruction algorithms (F=13.6, P<0.001 and slice thicknesses (F=4.4, P=0.02 had significant effects on the measured volume of pulmonary nodules. In addition, the coefficients of variation of nine measurements were inversely related with nodule diameter (r=-0.814, P<0.001. The volume measured at the 2.5 mm slice thickness had poor agreement with the volumes measured at 1.25 mm and 0.625 mm, respectively. Moreover, the best agreement was achieved between the slice thicknesses of 1.25 mm and 0.625 mm using the bone algorithm. Conclusion Reconstruction algorithms and slice thicknesses have significant impacts on the volumetric measurements of lung nodules, especially for the small nodules. Therefore, the reconstruction setting in serial CT scans should be consistent in the follow

  3. Gas sorption and the consequent volumetric and permeability change of coal

    Science.gov (United States)

    Lin, Wenjuan

    Experimental and numerical investigations of gas sorption on coal, and the subsequent volumetric and permeability changes of the coal were conducted. The goals of the study were to investigate the magnitude of permeability change caused by gas sorption, and develop an algorithm to simulate numerically gas sorption and sorption-induced permeability change. The amount of gas sorption and the subsequent volumetric and permeability change of coal samples as a function of pore pressure and injection gas composition were measured in the laboratory. A constant effective confining pressure (difference between the confining pressure and pore pressure) was maintained in the process of the experiments; therefore, the role of effective stress on permeability was eliminated. Several gases, including pure CO2, pure N2, and binary mixtures of CO2 and N2 of various compositions were used as the injection gas. The coal sample was first allowed to adsorb an injection gas fully at a particular pressure. The total amount (moles) of adsorption was calculated based on a volumetric method. After adsorption equilibrium was reached, gas samples were taken from the equilibrium gaseous phase and analyzed afterwards. The composition of the gaseous phase prior to and after the adsorption was used to calculate the composition of the adsorbed phase based on material balance. Permeability of the sample was then measured by flowing the injection gas through the core at varying pressure gradient or varying flow rate, and an average permeability was obtained based on Darcy's law for compressible systems. The change of the total volume of the core was monitored and recorded in the whole process of the experiment. Volumetric strain was thereby calculated. Experimental results showed that the greater the pressure the greater the amount of adsorption for all tested gases. At the same pressure, the amount of adsorption was greater for CO2 than N2. For the binary mixtures, the greater the fraction of CO 2

  4. Volumetric response classification in metastatic solid tumors on MSCT: Initial results in a whole-body setting

    Energy Technology Data Exchange (ETDEWEB)

    Wulff, A.M., E-mail: a.wulff@rad.uni-kiel.de [Klinik für Diagnostische Radiologie, Arnold-Heller-Straße 3, Haus 23, 24105 Kiel (Germany); Fabel, M. [Klinik für Diagnostische Radiologie, Arnold-Heller-Straße 3, Haus 23, 24105 Kiel (Germany); Freitag-Wolf, S., E-mail: freitag@medinfo.uni-kiel.de [Institut für Medizinische Informatik und Statistik, Brunswiker Str. 10, 24105 Kiel (Germany); Tepper, M., E-mail: m.tepper@rad.uni-kiel.de [Klinik für Diagnostische Radiologie, Arnold-Heller-Straße 3, Haus 23, 24105 Kiel (Germany); Knabe, H.M., E-mail: h.knabe@rad.uni-kiel.de [Klinik für Diagnostische Radiologie, Arnold-Heller-Straße 3, Haus 23, 24105 Kiel (Germany); Schäfer, J.P., E-mail: jp.schaefer@rad.uni-kiel.de [Klinik für Diagnostische Radiologie, Arnold-Heller-Straße 3, Haus 23, 24105 Kiel (Germany); Jansen, O., E-mail: o.jansen@neurorad.uni-kiel.de [Klinik für Diagnostische Radiologie, Arnold-Heller-Straße 3, Haus 23, 24105 Kiel (Germany); Bolte, H., E-mail: hendrik.bolte@ukmuenster.de [Klinik für Nuklearmedizin, Albert-Schweitzer-Campus 1, Gebäude A1, 48149 Münster (Germany)

    2013-10-01

    Purpose: To examine technical parameters of measurement accuracy and differences in tumor response classification using RECIST 1.1 and volumetric assessment in three common metastasis types (lung nodules, liver lesions, lymph node metastasis) simultaneously. Materials and methods: 56 consecutive patients (32 female) aged 41–82 years with a wide range of metastatic solid tumors were examined with MSCT for baseline and follow up. Images were evaluated by three experienced radiologists using manual measurements and semi-automatic lesion segmentation. Institutional ethics review was obtained and all patients gave written informed consent. Data analysis comprised interobserver variability operationalized as coefficient of variation and categorical response classification according to RECIST 1.1 for both manual and volumetric measures. Continuous data were assessed for statistical significance with Wilcoxon signed-rank test and categorical data with Fleiss kappa. Results: Interobserver variability was 6.3% (IQR 4.6%) for manual and 4.1% (IQR 4.4%) for volumetrically obtained sum of relevant diameters (p < 0.05, corrected). 4–8 patients’ response to therapy was classified differently across observers by using volumetry compared to standard manual measurements. Fleiss kappa revealed no significant difference in categorical agreement of response classification between manual (0.7558) and volumetric (0.7623) measurements. Conclusion: Under standard RECIST thresholds there was no advantage of volumetric compared to manual response evaluation. However volumetric assessment yielded significantly lower interobserver variability. This may allow narrower thresholds for volumetric response classification in the future.

  5. 4D ultrafast ultrasound flow imaging: in vivo quantification of arterial volumetric flow rate in a single heartbeat

    Science.gov (United States)

    Correia, Mafalda; Provost, Jean; Tanter, Mickael; Pernot, Mathieu

    2016-12-01

    We present herein 4D ultrafast ultrasound flow imaging, a novel ultrasound-based volumetric imaging technique for the quantitative mapping of blood flow. Complete volumetric blood flow distribution imaging was achieved through 2D tilted plane-wave insonification, 2D multi-angle cross-beam beamforming, and 3D vector Doppler velocity components estimation by least-squares fitting. 4D ultrafast ultrasound flow imaging was performed in large volumetric fields of view at very high volume rate (>4000 volumes s-1) using a 1024-channel 4D ultrafast ultrasound scanner and a 2D matrix-array transducer. The precision of the technique was evaluated in vitro by using 3D velocity vector maps to estimate volumetric flow rates in a vessel phantom. Volumetric Flow rate errors of less than 5% were found when volumetric flow rates and peak velocities were respectively less than 360 ml min-1 and 100 cm s-1. The average volumetric flow rate error increased to 18.3% when volumetric flow rates and peak velocities were up to 490 ml min-1 and 1.3 m s-1, respectively. The in vivo feasibility of the technique was shown in the carotid arteries of two healthy volunteers. The 3D blood flow velocity distribution was assessed during one cardiac cycle in a full volume and it was used to quantify volumetric flow rates (375  ±  57 ml min-1 and 275  ±  43 ml min-1). Finally, the formation of 3D vortices at the carotid artery bifurcation was imaged at high volume rates.

  6. Influence of Cobb Angle and ISIS2 Surface Topography Volumetric Asymmetry on Scoliosis Research Society-22 Outcome Scores in Scoliosis.

    Science.gov (United States)

    Brewer, Paul; Berryman, Fiona; Baker, De; Pynsent, Paul; Gardner, Adrian

    2013-11-01

    Retrospective sequential patient series. To establish the relationship between the magnitude of the deformity in scoliosis and patients' perception of their condition, as measured with Scoliosis Research Society-22 scores. A total of 93 untreated patients with adolescent idiopathic scoliosis were included retrospectively. The Cobb angle was measured from a plain radiograph, and volumetric asymmetry was measured by ISIS2 surface topography. The association between Scoliosis Research Society scores for function, pain, self-image, and mental health against Cobb angle and volumetric asymmetry was investigated using the Pearson correlation coefficient. Correlation of both Cobb angle and volumetric asymmetry with function and pain was weak (all self-image, was higher, although still moderate (-.37 for Cobb angle and -.44 for volumetric asymmetry). Both were statistically significant (Cobb angle, p = .0002; volumetric asymmetry; p = .00001). Cobb angle contributed 13.8% to the linear relationship with self-image, whereas volumetric asymmetry contributed 19.3%. For mental health, correlation was statistically significant with Cobb angle (p = .011) and volumetric asymmetry (p = .0005), but the correlation was low to moderate (-.26 and -.35, respectively). Cobb angle contributed 6.9% to the linear relationship with mental health, whereas volumetric asymmetry contributed 12.4%. Volumetric asymmetry correlates better with both mental health and self-image compared with Cobb angle, but the correlation was only moderate. This study suggests that a patient's own perception of self-image and mental health is multifactorial and not completely explained through present objective measurements of the size of the deformity. This helps to explain the difficulties in any objective analysis of a problem with multifactorial perception issues. Further study is required to investigate other physical aspects of the deformity that may have a role in how patients view themselves. Copyright

  7. Numerical evaluation of an innovative cup layout for open volumetric solar air receivers

    Science.gov (United States)

    Cagnoli, Mattia; Savoldi, Laura; Zanino, Roberto; Zaversky, Fritz

    2016-05-01

    This paper proposes an innovative volumetric solar absorber design to be used in high-temperature air receivers of solar power tower plants. The innovative absorber, a so-called CPC-stacked-plate configuration, applies the well-known principle of a compound parabolic concentrator (CPC) for the first time in a volumetric solar receiver, heating air to high temperatures. The proposed absorber configuration is analyzed numerically, applying first the open-source ray-tracing software Tonatiuh in order to obtain the solar flux distribution on the absorber's surfaces. Next, a Computational Fluid Dynamic (CFD) analysis of a representative single channel of the innovative receiver is performed, using the commercial CFD software ANSYS Fluent. The solution of the conjugate heat transfer problem shows that the behavior of the new absorber concept is promising, however further optimization of the geometry will be necessary in order to exceed the performance of the classical absorber designs.

  8. Volumetric analysis of complex lunar craters - Implications for basin ring formation

    Science.gov (United States)

    Hale, W. S.; Grieve, R. A. F.

    1982-01-01

    The crater to basin transition in complex lunar craters is characterized by combining morphological and volumetric analyses of their central peaks with subsurface data from terrestrial complex impact structures which suggest that the amount of uplifted material, as judged from its depth of origin, continues to increase with increasing rim diameter. This latter phenomenon implies that a redistribution of uplifted material away from a centralized peak may occur in the larger craters. The morphological and volumetric changes described occur over a rim diameter range of 51-80 km, which is considerably lower than the previously proposed range for the crater to basin transition of 140-175 km. Evidence is given in support of a crater to basin transition which begins at 51-80 km, and is characterized by a relative reduction in central peak volume and a development of rings of floor roughening which may be precursors of peak ring development.

  9. Volumetric characteristics and compactability of asphalt rubber mixtures with organic warm mix asphalt additives

    Directory of Open Access Journals (Sweden)

    A. M. Rodríguez-Alloza

    2017-04-01

    Full Text Available Warm Mix Asphalt (WMA refers to technologies that reduce manufacturing and compaction temperatures of asphalt mixtures allowing lower energy consumption and reducing greenhouse gas emissions from asphalt plants. These benefits, combined with the effective reuse of a solid waste product, make asphalt rubber (AR mixtures with WMA additives an excellent environmentally-friendly material for road construction. The effect of WMA additives on rubberized mixtures has not yet been established in detail and the lower mixing/compaction temperatures of these mixtures may result in insufficient compaction. In this sense, the present study uses a series of laboratory tests to evaluate the volumetric characteristics and compactability of AR mixtures with organic additives when production/compaction temperatures are decreased. The results of this study indicate that the additives selected can decrease the mixing/compaction temperatures without compromising the volumetric characteristics and compactability.

  10. Open Volumetric Mesh-An Efficient Data Structure for Tetrahedral and Hexa-hedral Meshes

    Institute of Scientific and Technical Information of China (English)

    XIAN Chu-hua; LI Gui-qing; GAO Shu-ming

    2013-01-01

    This work introduces a scalable and efficient topological structure for tetrahedral and hexahedral meshes. The design of the data structure aims at maximal flexibility and high performance. It provides a high scalability by using hierarchical representa-tions of topological elements. The proposed data structure is array-based, and it is a compact representation of the half-edge data structure for volume elements and half-face data structure for volumetric meshes. This guarantees constant access time to the neighbors of the topological elements. In addition, an open-source implementation named Open Volumetric Mesh (OVM) of the pro-posed data structure is written in C++using generic programming concepts.

  11. Selective-plane illumination microscopy for high-content volumetric biological imaging

    Science.gov (United States)

    McGorty, Ryan; Huang, Bo

    2016-03-01

    Light-sheet microscopy, also named selective-plane illumination microscopy, enables optical sectioning with minimal light delivered to the sample. Therefore, it allows one to gather volumetric datasets of developing embryos and other light-sensitive samples over extended times. We have configured a light-sheet microscope that, unlike most previous designs, can image samples in formats compatible with high-content imaging. Our microscope can be used with multi-well plates or with microfluidic devices. In designing our optical system to accommodate these types of sample holders we encounter large optical aberrations. We counter these aberrations with both static optical components in the imaging path and with adaptive optics. Potential applications of this microscope include studying the development of a large number of embryos in parallel and over long times with subcellular resolution and doing high-throughput screens on organisms or cells where volumetric data is necessary.

  12. Light-Curing Volumetric Shrinkage in Dimethacrylate-Based Dental Composites by Nanoindentation and PAL Study

    Science.gov (United States)

    Shpotyuk, Olha; Adamiak, Stanislaw; Bezvushko, Elvira; Cebulski, Jozef; Iskiv, Maryana; Shpotyuk, Oleh; Balitska, Valentina

    2017-01-01

    Light-curing volumetric shrinkage in dimethacrylate-based dental resin composites Dipol® is examined through comprehensive kinetics research employing nanoindentation measurements and nanoscale atomic-deficient study with lifetime spectroscopy of annihilating positrons. Photopolymerization kinetics determined through nanoindentation testing is shown to be described via single-exponential relaxation function with character time constants reaching respectively 15.0 and 18.7 s for nanohardness and elastic modulus. Atomic-deficient characteristics of composites are extracted from positron lifetime spectra parameterized employing unconstrained x3-term fitting. The tested photopolymerization kinetics can be adequately reflected in time-dependent changes observed in average positron lifetime (with 17.9 s time constant) and fractional free volume of positronium traps (with 18.6 s time constant). This correlation proves that fragmentation of free-volume positronium-trapping sites accompanied by partial positronium-to-positron traps conversion determines the light-curing volumetric shrinkage in the studied composites.

  13. Computational determination of absorbed dose distributions from multiple volumetric gamma ray sources

    Science.gov (United States)

    Zhou, Chuanyu; Inanc, Feyzi

    2002-05-01

    Determination of absorbed dose distributions is very important in brachytherapy procedures. The typical computation involves superposition of absorbed dose distributions from a single seed to compute the combined absorbed dose distribution formed by multiple seeds. This approach does not account for the shadow effect caused by the metallic nature of volumetric radioactive seeds. Since this shadow effect will cause deviations from the targeted dose distribution, it may have important implications on the success of the procedures. We demonstrated accuracy of our deterministic algorithms for isotropic point sources in the past. We will show that we now have the capability of computing absorbed dose distributions from multiple volumetric seeds and demonstrate that our results are quite close to the results published in the literature.

  14. GPU-based Scalable Volumetric Reconstruction for Multi-view Stereo

    Energy Technology Data Exchange (ETDEWEB)

    Kim, H; Duchaineau, M; Max, N

    2011-09-21

    We present a new scalable volumetric reconstruction algorithm for multi-view stereo using a graphics processing unit (GPU). It is an effectively parallelized GPU algorithm that simultaneously uses a large number of GPU threads, each of which performs voxel carving, in order to integrate depth maps with images from multiple views. Each depth map, triangulated from pair-wise semi-dense correspondences, represents a view-dependent surface of the scene. This algorithm also provides scalability for large-scale scene reconstruction in a high resolution voxel grid by utilizing streaming and parallel computation. The output is a photo-realistic 3D scene model in a volumetric or point-based representation. We demonstrate the effectiveness and the speed of our algorithm with a synthetic scene and real urban/outdoor scenes. Our method can also be integrated with existing multi-view stereo algorithms such as PMVS2 to fill holes or gaps in textureless regions.

  15. Volumetric properties of binary mixtures of benzene with cyano-based ionic liquids

    Science.gov (United States)

    Gonfa, Girma; Bustam, Mohamad Azmi; Moniruzzaman, Muhammad; Murugesan, Thanabalan

    2014-10-01

    The objective of this study is to investigate the volumetric properties of the binary mixtures comprised benzene and two ionic liquids, 1-butyl-3-methylimidazolium thiocyanate ([BMIM][SCN]) and 1-butyl-3-methyl- imidazolium dicyanamide ([ BMIM ][ N ( CN )2]( . Densities (ρ) and viscosities (μ) of the binary mixtures were measured over a temperature range of 293.15 to 323.15 K and at atmospheric pressure. Excess molar volumes and viscosity deviations were calculated from the experimental densities and viscosities values. The volumetric properties of the mixtures were changed significantly with the change of compositions and temperatures. It was also found that the value of excess molar volume and viscosity deviations were negative (-ve) over the entire range of compositions. The results have been interpreted in terms of molecular interactions of ILs and benzene.

  16. Holographic time-resolved particle tracking by means of three-dimensional volumetric deconvolution

    CERN Document Server

    Latychevskaia, Tatiana

    2014-01-01

    Holographic particle image velocimetry allows tracking particle trajectories in time and space by means of holography. However, the drawback of the technique is that in the three-dimensional particle distribution reconstructed from a hologram, the individual particles can hardly be resolved due to the superimposed out-of-focus signal from neighboring particles. We demonstrate here a three-dimensional volumetric deconvolution applied to the reconstructed wavefront which results in resolving all particles simultaneously in three-dimensions. Moreover, we apply the three-dimensional volumetric deconvolution to reconstructions of a time-dependent sequence of holograms of an ensemble of polystyrene spheres moving in water. From each hologram we simultaneously resolve all particles in the ensemble in three dimensions and from the sequence of holograms we obtain the time-resolved trajectories of individual polystyrene spheres.

  17. Development of a Diver-Operated Single Camera Volumetric Velocimetry System

    Science.gov (United States)

    Troutman, Valerie; Dabiri, John

    2016-11-01

    The capabilities of a single camera, volumetric velocimetry system for in situ measurement in marine environments are demonstrated by imaging a well-characterized flow in a laboratory environment. This work represents the first stages in the design of a SCUBA-diver operated system to study organisms and biological processes under the natural light in the water column. This system is primarily composed of a volumetric particle tracking diagnostic to investigate fluid-animal interactions. A target domain size of a 20 cm sided cube is sought as a key design feature for the capability of capturing the flow around a variety of benthic and freely swimming organisms. The integration of the particle tracking system with additional diagnostics will be discussed.

  18. Tunable Gravimetric and Volumetric Hydrogen Storage Capacities in Polyhedral Oligomeric Silsesquioxane Frameworks.

    Science.gov (United States)

    Deshmukh, Amol; Chiu, Cheng-Chau; Chen, Yun-Wen; Kuo, Jer-Lai

    2016-09-28

    We study the hydrogen adsorption in porous frameworks composed of silsesquioxane cages linked via boron substituted aromatic structures by first-principles modeling. Such polyhedral oligomeric silsesquioxane (POSS) frameworks can be further modified by decorating them with metal atoms binding to the ring structures of the linkers. We have considered Sc- and Ti-doped frameworks which bind H2 via so-called Kubas interaction between hydrogen molecules and transition metal atoms. It will be demonstrated that the maximum H2 gravimetric capacity can be improved to more than 7.5 wt % by using longer linkers with more ring structures. However, the maximum H2 volumetric capacity can be tuned to more than 70 g/L by varying the size of silsesquioxane cages. We are optimistic that by varying the building blocks, POSS frameworks can be modified to meet the targets for the gravimetric and volumetric capacities set by the U.S. Department of Energy.

  19. The Simulation of High Reynolds Number Cavity Flow Based on Fractional Volumetric Lattice Boltzmann Method

    Institute of Scientific and Technical Information of China (English)

    HAN Shan-ling; ZHU Ping; LIN Zhong-qin

    2005-01-01

    The fractional volumetric lattice Boltzmann method with much better stability was used to simulate two dimensional cavity flows. Because the effective viscosity was reduced by the fraction factor, it is very effective forsimulating high Reynolds number flows. Simulations were carried out on a uniform grids system. The stream lines and the velocity profiles obtained from the simulations agree well with the standard lattice Boltzmann method simulations. Comparisons of detailed flow patterns with other studies via location of vortex centers are also satisfactory.

  20. Theoretical and Experimental Estimations of Volumetric Inductive Phase Shift in Breast Cancer Tissue

    Science.gov (United States)

    González, C. A.; Lozano, L. M.; Uscanga, M. C.; Silva, J. G.; Polo, S. M.

    2013-04-01

    Impedance measurements based on magnetic induction for breast cancer detection has been proposed in some studies. This study evaluates theoretical and experimentally the use of a non-invasive technique based on magnetic induction for detection of patho-physiological conditions in breast cancer tissue associated to its volumetric electrical conductivity changes through inductive phase shift measurements. An induction coils-breast 3D pixel model was designed and tested. The model involves two circular coils coaxially centered and a human breast volume centrally placed with respect to the coils. A time-harmonic numerical simulation study addressed the effects of frequency-dependent electrical properties of tumoral tissue on the volumetric inductive phase shift of the breast model measured with the circular coils as inductor and sensor elements. Experimentally; five female volunteer patients with infiltrating ductal carcinoma previously diagnosed by the radiology and oncology departments of the Specialty Clinic for Women of the Mexican Army were measured by an experimental inductive spectrometer and the use of an ergonomic inductor-sensor coil designed to estimate the volumetric inductive phase shift in human breast tissue. Theoretical and experimental inductive phase shift estimations were developed at four frequencies: 0.01, 0.1, 1 and 10 MHz. The theoretical estimations were qualitatively in agreement with the experimental findings. Important increments in volumetric inductive phase shift measurements were evident at 0.01MHz in theoretical and experimental observations. The results suggest that the tested technique has the potential to detect pathological conditions in breast tissue associated to cancer by non-invasive monitoring. Further complementary studies are warranted to confirm the observations.

  1. Optimization of element length for imaging small volumetric reflectors with linear ultrasonic arrays

    OpenAIRE

    Barber, T. S.; Wilcox, P. D.; Nixon, A. D.

    2016-01-01

    A 3D ultrasonic simulation study is presented, aimed at understanding the effect of element length for imaging small volumetric flaws with linear arrays in ultrasonically noisy materials. The geometry of a linear array can be described by the width, pitch and total number of the elements along with the length perpendicular to imaging plane. This paper is concerned with the latter parameter, which tends to be ignored in array optimization studies and is often chosen arbitrarily for industrial ...

  2. Predicting Offshore Swarm Rate Changes by Volumetric Strain Changes in Izu Peninsula, Japan

    Science.gov (United States)

    Kumazawa, T.; Ogata, Y.; Kimura, Y.; Maeda, K.; Kobayashi, A.

    2014-12-01

    The eastern offshore of Izu peninsula is one of the well known volcanic active regions in Japan, where magma intrusions have been observed several times since 1980s monitored by strain-meters located nearby. Major swarm activities have been synchronously associated with coseismic and preseismic significant sizes of a volumetric strain changes (Earthquake Research Committee, 2010). We investigated the background seismicity changes during these earthquake swarms using the nonstationary ETAS model (Kumazawa and Ogata, 2013), and have found the followings. The modified volumetric strain change data by removing the effect of earth tides and precipitation as well as removing coseismic jumps have much higher cross-correlations to the background rates of the ETAS model than to the whole seismicity rate change of the ETAS, and further the strain changes precede the background seismicity by lag of about a day. This relation suggests an enhanced prediction of earthquakes in this region using volumetric strain measurements. Thus we propose an extended ETAS model where the background seismicity rate is predicted by the time series of preceding volumetric strain changes. Our numerical results for Izu region show consistent outcomes throughout the major swarms in this region. References Earthquake Research Committee (2010). Report on "Prediction of seismic activity in the Izu Eastern Region" (in Japanese), http://www.jishin.go.jp/main/yosoku/izu/index.htm Kumazawa, T. and Ogata, Y. (2013). Quantitative description of induced seismic activity before and after the 2011 Tohoku-Oki earthquake by nonstationary ETAS model, J Geophys.Res. 118, 6165-6182.

  3. Development of Mathematical Models for Detecting Micron Scale Volumetric Defects in Thin Film Coatings

    Directory of Open Access Journals (Sweden)

    Gaigals G.

    2016-04-01

    Full Text Available The focus of the present research is to investigate possibilities of volumetric defect detection in thin film coatings on glass substrates by means of high definition imaging with no complex optical systems, such as lenses, and to determine development and construction feasibility of a defectoscope employing the investigated methods. Numerical simulations were used to test the proposed methods. Three theoretical models providing various degrees of accuracy and feasibility were studied.

  4. Simultaneously high gravimetric and volumetric methane uptake characteristics of the metal-organic framework NU-111.

    Science.gov (United States)

    Peng, Yang; Srinivas, Gadipelli; Wilmer, Christopher E; Eryazici, Ibrahim; Snurr, Randall Q; Hupp, Joseph T; Yildirim, Taner; Farha, Omar K

    2013-04-14

    We show that the MOF NU-111 exhibits equally high volumetric and gravimetric methane uptake values, both within ≈75% of the DOE targets at 300 K. Upon reducing the temperature to 270 K, the uptake increases to 0.5 g g(-1) and 284 cc(STP) per cc at 65 bar. Adsorption of CO2 and H2 is also reported. Simulated isotherms are in excellent agreement with those obtained from experiments.

  5. Rapidly-steered single-element ultrasound for real-time volumetric imaging and guidance

    Science.gov (United States)

    Stauber, Mark; Western, Craig; Solek, Roman; Salisbury, Kenneth; Hristov, Dmitre; Schlosser, Jeffrey

    2016-03-01

    Volumetric ultrasound (US) imaging has the potential to provide real-time anatomical imaging with high soft-tissue contrast in a variety of diagnostic and therapeutic guidance applications. However, existing volumetric US machines utilize "wobbling" linear phased array or matrix phased array transducers which are costly to manufacture and necessitate bulky external processing units. To drastically reduce cost, improve portability, and reduce footprint, we propose a rapidly-steered single-element volumetric US imaging system. In this paper we explore the feasibility of this system with a proof-of-concept single-element volumetric US imaging device. The device uses a multi-directional raster-scan technique to generate a series of two-dimensional (2D) slices that were reconstructed into three-dimensional (3D) volumes. At 15 cm depth, 90° lateral field of view (FOV), and 20° elevation FOV, the device produced 20-slice volumes at a rate of 0.8 Hz. Imaging performance was evaluated using an US phantom. Spatial resolution was 2.0 mm, 4.7 mm, and 5.0 mm in the axial, lateral, and elevational directions at 7.5 cm. Relative motion of phantom targets were automatically tracked within US volumes with a mean error of -0.3+/-0.3 mm, -0.3+/-0.3 mm, and -0.1+/-0.5 mm in the axial, lateral, and elevational directions, respectively. The device exhibited a mean spatial distortion error of 0.3+/-0.9 mm, 0.4+/-0.7 mm, and -0.3+/-1.9 in the axial, lateral, and elevational directions. With a production cost near $1000, the performance characteristics of the proposed system make it an ideal candidate for diagnostic and image-guided therapy applications where form factor and low cost are paramount.

  6. A multistage volumetric bar chart chip for visualized quantification of DNA

    OpenAIRE

    Song, Yujun; Wang, Yuanchen; Qin, Lidong

    2013-01-01

    Nucleic acid detection is critical in disease diagnosis as well as in the environmental assays of harmful bacteria or viruses and forensic applications. Current methods for visualized quantification of DNA require costly and sophisticated instruments. Here, we report a multistage propelled volumetric bar chart chip (MV-Chip) for multiplexing and quantitative detection of DNA. Owing to its ‘rocket-like’ propelling reaction, the pre-deposited platinum films could perform cascade amplification a...

  7. Impact of turbocharger non-adiabatic operation on engine volumetric efficiency and turbo lag

    OpenAIRE

    S. Shaaban; Seume, J.

    2012-01-01

    Turbocharger performance significantly affects the thermodynamic properties of the working fluid at engine boundaries and hence engine performance. Heat transfer takes place under all circumstances during turbocharger operation. This heat transfer affects the power produced by the turbine, the power consumed by the compressor, and the engine volumetric efficiency. Therefore, non-adiabatic turbocharger performance can restrict the engine charging process and hence engine performance. The prese...

  8. Impact of Turbocharger Non-Adiabatic Operation on Engine Volumetric Efficiency and Turbo Lag

    OpenAIRE

    S. Shaaban; Seume, J.

    2012-01-01

    Turbocharger performance significantly affects the thermodynamic properties of the working fluid at engine boundaries and hence engine performance. Heat transfer takes place under all circumstances during turbocharger operation. This heat transfer affects the power produced by the turbine, the power consumed by the compressor, and the engine volumetric efficiency. Therefore, non-adiabatic turbocharger performance can restrict the engine charging process and hence engine performance. The prese...

  9. PEMODELAN OBYEK TIGA DIMENSI DARI GAMBAR SINTETIS DUA DIMENSI DENGAN PENDEKATAN VOLUMETRIC

    Directory of Open Access Journals (Sweden)

    Rudy Adipranata

    2005-01-01

    Full Text Available In this paper, we implemented 3D object modeling from 2D input images. Modeling is performed by using volumetric reconstruction approaches by using volumetric reconstruction approaches, the 3D space is tesselated into discrete volumes called voxels. We use voxel coloring method to reconstruct 3D object from synthetic input images by using voxel coloring, we can get photorealistic result and also has advantage to solve occlusion problem that occur in many case of 3D reconstruction. Photorealistic 3D object reconstruction is a challenging problem in computer graphics and still an active area nowadays. Many applications that make use the result of reconstruction, include virtual reality, augmented reality, 3D games, and another 3D applications. Voxel coloring considered the reconstruction problem as a color reconstruction problem, instead of shape reconstruction problem. This method works by discretizing scene space into voxels, then traversed and colored those voxels in special order. The result is photorealitstic 3D object. Abstract in Bahasa Indonesia : Dalam penelitian ini dilakukan implementasi untuk pemodelan obyek tiga dimensi yang berasal dari gambar dua dimensi. Pemodelan ini dilakukan dengan menggunakan pendekatan volumetric. Dengan menggunakan pendekatan volumetric, ruang tiga dimensi dibagi menjadi bentuk diskrit yang disebut voxel. Kemudian pada voxel-voxel tersebut dilakukan metode pewarnaan voxel untuk mendapatkan hasil berupa obyek tiga dimensi yang bersifat photorealistic. Bagaimana memodelkan obyek tiga dimensi untuk menghasilkan hasil photorealistic merupakan masalah yang masih aktif di bidang komputer grafik. Banyak aplikasi lain yang dapat memanfaatkan hasil dari pemodelan tersebut seperti virtual reality, augmented reality dan lain-lain. Pewarnaan voxel merupakan pemodelan obyek tiga dimensi dengan melakukan rekonstruksi warna, bukan rekonstruksi bentuk. Metode ini bekerja dengan cara mendiskritkan obyek menjadi voxel dan

  10. An Autologous Muscle Tissue Expansion Approach for the Treatment of Volumetric Muscle Loss

    Science.gov (United States)

    2015-07-01

    ORIGINAL RESEARCH ARTICLE Open Access An Autologous Muscle Tissue Expansion Approach for the Treatment of Volumetric Muscle Loss Catherine L. Ward...regeneration. But they require ample donor muscle tissue and therefore may be limited in their application for large clinical VML. Here, we tested the...autologous minced grafts for the regeneration of muscle tissue after VML, but indicate the need to identify optimal carrier materials for expansion

  11. Water content influence on thermal and volumetric properties of wheat starch gelatinization under 10 MPa.

    Science.gov (United States)

    Orlowska, Marta; Randzio, Stanislaw L

    2010-02-01

    A transitiometric in situ analysis of wheat starch aqueous suspensions heated over a temperature range from 285 K to 415 K under isobaric conditions of 10 MPa is presented. Measurements were performed at four selected water concentrations: 56.0%, 64.7%, 73.5%, and 82.4% weight/water. Thermal and volumetric properties and their water content dependencies have been determined for three successive starch phase transformations occurred during wheat starch gelatinization.

  12. Volumetric and superficial characterization of carbon activated; Caracterizacion volumetrica y superficial de carbon activado

    Energy Technology Data Exchange (ETDEWEB)

    Carrera G, L.M.; Garcia S, I.; Jimenez B, J.; Solache R, M.; Lopez M, B.; Bulbulian G, S.; Olguin G, M.T. [Departamento de Quimica, Gerencia de Ciencias Basicas, Instituto Nacional de Investigaciones Nucleares, A.P. 18-1027, 11801 Mexico D.F. (Mexico)

    2000-07-01

    The activated carbon is the resultant material of the calcination process of natural carbonated materials as coconut shells or olive little bones. It is an excellent adsorbent of diluted substances, so much in colloidal form, as in particles form. Those substances are attracted and retained by the carbon surface. In this work is make the volumetric and superficial characterization of activated carbon treated thermically (300 Centigrade) in function of the grain size average. (Author)

  13. The diagnostic contribution of CT volumetric rendering techniques in routine practice

    OpenAIRE

    Perandini Simone; Faccioli N; Zaccarella A; Re T; Mucelli R

    2010-01-01

    Computed tomography (CT) volumetric rendering techniques such as maximum intensity projection (MIP), minimum intensity projection (MinIP), shaded surface display (SSD), volume rendering (VR), and virtual endoscopy (VE) provide added diagnostic capabilities. The diagnostic value of such reconstruction techniques is well documented in literature. These techniques permit the exploration of fine anatomical detail that would be difficult to evaluate using axial reconstructions alone. Although thes...

  14. A new laboratory-scale experimental facility for detailed aerothermal characterizations of volumetric absorbers

    Science.gov (United States)

    Gomez-Garcia, Fabrisio; Santiago, Sergio; Luque, Salvador; Romero, Manuel; Gonzalez-Aguilar, Jose

    2016-05-01

    This paper describes a new modular laboratory-scale experimental facility that was designed to conduct detailed aerothermal characterizations of volumetric absorbers for use in concentrating solar power plants. Absorbers are generally considered to be the element with the highest potential for efficiency gains in solar thermal energy systems. The configu-ration of volumetric absorbers enables concentrated solar radiation to penetrate deep into their solid structure, where it is progressively absorbed, prior to being transferred by convection to a working fluid flowing through the structure. Current design trends towards higher absorber outlet temperatures have led to the use of complex intricate geometries in novel ceramic and metallic elements to maximize the temperature deep inside the structure (thus reducing thermal emission losses at the front surface and increasing efficiency). Although numerical models simulate the conjugate heat transfer mechanisms along volumetric absorbers, they lack, in many cases, the accuracy that is required for precise aerothermal validations. The present work aims to aid this objective by the design, development, commissioning and operation of a new experimental facility which consists of a 7 kWe (1.2 kWth) high flux solar simulator, a radiation homogenizer, inlet and outlet collector modules and a working section that can accommodate volumetric absorbers up to 80 mm × 80 mm in cross-sectional area. Experimental measurements conducted in the facility include absorber solid temperature distributions along its depth, inlet and outlet air temperatures, air mass flow rate and pressure drop, incident radiative heat flux, and overall thermal efficiency. In addition, two windows allow for the direct visualization of the front and rear absorber surfaces, thus enabling full-coverage surface temperature measurements by thermal imaging cameras. This paper presents the results from the aerothermal characterization of a siliconized silicon

  15. Comparative analysis of volumetric flow meters used for mass flow estimation in multiphase and multidensity environments

    Science.gov (United States)

    Pedone, Richard; Korman, Valentin; Wiley, John T.

    2006-05-01

    Accurate and reliable multiphase flow measurements are needed for liquid propulsion systems. Existing volumetric flow meters are adequate for flow measurements with well-characterized, clean liquids and gases. However, these technologies are inadequate for multiphase environments, such as cryogenic fluids. Although, properly calibrated turbine flow meters can provide highly accurate and repeatable data, problems are still prevalent with multiphase flows. Limitations are thus placed on the applicability of intrusive turbine flow meters.

  16. Template-assisted low temperature synthesis of functionalized graphene for ultrahigh volumetric performance supercapacitors.

    Science.gov (United States)

    Yan, Jun; Wang, Qian; Wei, Tong; Jiang, Lili; Zhang, Milin; Jing, Xiaoyan; Fan, Zhuangjun

    2014-05-27

    We demonstrated the fabrication of functionalized graphene nanosheets via low temperature (300 °C) treatment of graphite oxide with a slow heating rate using Mg(OH)2 nanosheets as template. Because of its dented sheet with high surface area, a certain amount of oxygen-containing groups, and low pore volume, the as-obtained graphene delivers both ultrahigh specific gravimetric and volumetric capacitances of 456 F g(-1) and 470 F cm(-3), almost 3.7 times and 3.3 times higher than hydrazine reduced graphene, respectively. Especially, the obtained volumetric capacitance is the highest value so far reported for carbon materials in aqueous electrolytes. More importantly, the assembled supercapacitor exhibits an ultrahigh volumetric energy density of 27.2 Wh L(-1), which is among the highest values for carbon materials in aqueous electrolytes, as well as excellent cycling stability with 134% of its initial capacitance after 10,000 cycles. Therefore, the present work holds a great promise for future design and large-scale production of high performance graphene electrodes for portable energy storage devices.

  17. The prognostic role of prenatal MRI volumetric assessment in fetuses with isolated ventriculomegaly.

    Science.gov (United States)

    Gezer, Naciye Sinem; Güleryüz, Handan; Gezer, Cenk; Koçyiğit, Ali; Yeşilırmak, Didem; Ekin, Atalay; Bilgin, Muzaffer; Ertaş, İbrahim Egemen

    2015-01-01

    In this prospective study, we aimed to establish the value of volumetric assessment by prenatal brain MRI in determining the prognosis of fetuses with isolated VM. A total of 23 fetuses with isolated VM were included in the study. Supratentorial cerebral parenchyma volume (PV) and ventricular volume (VV) were measured, and supratentorial ventricular/parenchymal volume (VV/PV) ratios were calculated. Pregnancy and postnatal neurodevelopmental outcomes up to two years of age were obtained and correlated with the volumetric measurements. VV was found to be strongly and positively correlated with ventricular dimension. There was a statistically significant difference between the VV/ PV ratios of the good and poor prognosis groups into which the cases had been categorized. The fetuses with a poor prognosis had a significantly higher VV/PV ratio. Volumetric parenchymal and ventricular measurements obtained by fetal brain MRI may contribute to future clinical studies concerning the evaluation of fetuses with VM and provide an important indicator in cases where management dilemmas arise.

  18. The effect of volumetric (3D) tactile symbols within inclusive tactile maps.

    Science.gov (United States)

    Gual, Jaume; Puyuelo, Marina; Lloveras, Joaquim

    2015-05-01

    Point, linear and areal elements, which are two-dimensional and of a graphic nature, are the morphological elements employed when designing tactile maps and symbols for visually impaired users. However, beyond the two-dimensional domain, there is a fourth group of elements - volumetric elements - which mapmakers do not take sufficiently into account when it comes to designing tactile maps and symbols. This study analyses the effect of including volumetric, or 3D, symbols within a tactile map. In order to do so, the researchers compared two tactile maps. One of them uses only two-dimensional elements and is produced using thermoforming, one of the most popular systems in this field, while the other includes volumetric symbols, thus highlighting the possibilities opened up by 3D printing, a new area of production. The results of the study show that including 3D symbols improves the efficiency and autonomous use of these products. Copyright © 2014 Elsevier Ltd and The Ergonomics Society. All rights reserved.

  19. [Change in condylar and mandibular morphology in juvenile idiopathic arthritis: cone beam volumetric imaging].

    Science.gov (United States)

    Garagiola, Umberto; Mercatali, Lorenzo; Bellintani, Claudio; Fodor, Attila; Farronato, Giampietro; Lőrincz, Adám

    2013-03-01

    The aim of this study is to show the importance of Cone Beam Computerized Tomography to volumetrically quantify TMJ damage in patients with JIA, measuring condylar and mandibular real volumes. 34 children with temporomandibular involvement by Juvenile Idiopathic Arthritis were observed by Cone Beam Computerized Tomography. 4 were excluded because of several imaging noises. The mandible was isolated from others craniofacial structures; the whole mandibular volume and its components' volumes (condyle, ramus, hemibody, hemisymphysis on right side and on left side) has been calculated by a 3D volume rendering technique. The results show a highly significant statistical difference between affected side volumetric values versus normal side volumetric values above all on condyle region (P < 0.01), while they don't show any statistical differences between right side versus left side. The Cone Beam Computerized Tomography represents a huge improvement in understanding of the condyle and mandibular morphological changes, even in the early stages of the Juvenile Idiopathic Arthritis. The JIA can lead in children to temporomandibular joint damage with facial development and growth alterations.

  20. Verbal Memory Decline following DBS for Parkinson’s Disease: Structural Volumetric MRI Relationships

    Science.gov (United States)

    Geevarghese, Ruben; Lumsden, Daniel E.; Costello, Angela; Hulse, Natasha; Ayis, Salma; Samuel, Michael; Ashkan, Keyoumars

    2016-01-01

    Background Parkinson’s disease is a chronic degenerative movement disorder. The mainstay of treatment is medical. In certain patients Deep Brain Stimulation (DBS) may be offered. However, DBS has been associated with post-operative neuropsychology changes, especially in verbal memory. Objectives Firstly, to determine if pre-surgical thalamic and hippocampal volumes were related to verbal memory changes following DBS. Secondly, to determine if clinical factors such as age, duration of symptoms or motor severity (UPDRS Part III score) were related to verbal memory changes. Methods A consecutive group of 40 patients undergoing bilateral Subthalamic Nucleus (STN)-DBS for PD were selected. Brain MRI data was acquired, pre-processed and structural volumetric data was extracted using FSL. Verbal memory test scores for pre- and post-STN-DBS surgery were recorded. Linear regression was used to investigate the relationship between score change and structural volumetric data. Results A significant relationship was demonstrated between change in List Learning test score and thalamic (left, p = 0.02) and hippocampal (left, p = 0.02 and right p = 0.03) volumes. Duration of symptoms was also associated with List Learning score change (p = 0.02 to 0.03). Conclusion Verbal memory score changes appear to have a relationship to pre-surgical MRI structural volumetric data. The findings of this study provide a basis for further research into the use of pre-surgical MRI to counsel PD patients regarding post-surgical verbal memory changes. PMID:27557088

  1. A Solar Volumetric Receiver: Influence of Absorbing Cells Configuration on Device Thermal Performance

    Science.gov (United States)

    Yilbas, B. S.; Shuja, S. Z.

    2017-01-01

    Thermal performance of a solar volumetric receiver incorporating the different cell geometric configurations is investigated. Triangular, hexagonal, and rectangular absorbing cells are incorporated in the analysis. The fluid volume fraction, which is the ratio of the volume of the working fluid over the total volume of solar volumetric receiver, is introduced to assess the effect of cell size on the heat transfer rates in the receiver. In this case, reducing the fluid volume fraction corresponds to increasing cell size in the receiver. SiC is considered as the cell material, and air is used as the working fluid in the receiver. The Lambert's Beer law is incorporated to account for the solar absorption in the receiver. A finite element method is used to solve the governing equation of flow and heat transfer. It is found that the fluid volume fraction has significant effect on the flow field in the solar volumetric receiver, which also modifies thermal field in the working fluid. The triangular absorbing cell gives rise to improved effectiveness of the receiver and then follows the hexagonal and rectangular cells. The second law efficiency of the receiver remains high when hexagonal cells are used. This occurs for the fluid volume fraction ratio of 0.5.

  2. VOLUMETRIC ERROR COMPENSATION IN FIVE-AXIS CNC MACHINING CENTER THROUGH KINEMATICS MODELING OF GEOMETRIC ERROR

    Directory of Open Access Journals (Sweden)

    Pooyan Vahidi Pashsaki

    2016-06-01

    Full Text Available Accuracy of a five-axis CNC machine tool is affected by a vast number of error sources. This paper investigates volumetric error modeling and its compensation to the basis for creation of new tool path for improvement of work pieces accuracy. The volumetric error model of a five-axis machine tool with the configuration RTTTR (tilting head B-axis and rotary table in work piece side A΄ was set up taking into consideration rigid body kinematics and homogeneous transformation matrix, in which 43 error components are included. Volumetric error comprises 43 error components that can separately reduce geometrical and dimensional accuracy of work pieces. The machining accuracy of work piece is guaranteed due to the position of the cutting tool center point (TCP relative to the work piece. The cutting tool is deviated from its ideal position relative to the work piece and machining error is experienced. For compensation process detection of the present tool path and analysis of the RTTTR five-axis CNC machine tools geometrical error, translating current position of component to compensated positions using the Kinematics error model, converting newly created component to new tool paths using the compensation algorithms and finally editing old G-codes using G-code generator algorithm have been employed.

  3. Brain stem and cerebellum volumetric analysis of Machado Joseph disease patients

    Directory of Open Access Journals (Sweden)

    S T Camargos

    2011-01-01

    Full Text Available Machado-Joseph disease, or spinocerebellar ataxia type 3(MJD/SCA3, is the most frequent late onset spinocerebellar ataxia and results from a CAG repeat expansion in the ataxin-3 gene. Previous studies have found correlation between atrophy of cerebellum and brainstem with age and CAG repeats, although no such correlation has been found with disease duration and clinical manifestations. In this study we test the hypothesis that atrophy of cerebellum and brainstem in MJD/SCA3 is related to clinical severity, disease duration and CAG repeat length as well as to other variables such as age and ICARS (International Cooperative Ataxia Rating Scale. Whole brain high resolution MRI and volumetric measurement with cranial volume normalization were obtained from 15 MJD/SCA3 patients and 15 normal, age and sex-matchedcontrols. We applied ICARS and compared the score with volumes and CAG number, disease duration and age. We found significant correlation of both brain stem and cerebellar atrophy with CAG repeat length, age, disease duration and degree of disability. The Spearman rank correlation was stronger with volumetric reduction of the cerebellum than with brain stem. Our data allow us to conclude that volumetric analysis might reveal progressive degeneration after disease onset, which in turn is linked to both age and number of CAG repeat expansions in SCA 3.

  4. Volumetric flow rate comparisons for water and product on pasteurization systems.

    Science.gov (United States)

    Schlesser, J E; Stroup, W H; McKinstry, J A

    1994-04-01

    A flow calibration tube system was assembled to determine the volumetric flow rates for water and various dairy products through a holding tube, using three different flow promotion methods. With the homogenizer, the volumetric flow rates of water and reconstituted skim milk were within 1.5% of each other. With the positive displacement pump, the flow rate for reconstituted skim milk increased compared with that for water as the pressure increased or temperature decreased. The largest increase in flow rate was at 310-kPa gauge and 20 degrees C. On a magnetic flow meter system, the volumetric flow rates of water and reconstituted skim milk were within .5% of the flow rate measured from the volume collected in a calibrated tank. The flow rate of whole milk was similar to that of skim milk on the three flow promoters evaluated. Ice milk mix increased the flow rate of the positive displacement pump, but not the homogenizer and magnetic flow meter system.

  5. Microfabricated pseudocapacitors using Ni(OH)2 electrodes exhibit remarkable volumetric capacitance and energy density

    KAUST Repository

    Kurra, Narendra

    2014-09-10

    Metal hydroxide based microfabricated pseudocapacitors with impressive volumetric stack capacitance and energy density are demonstrated. A combination of top-down photolithographic process and bottom-up chemical synthesis is employed to fabricate the micro-pseudocapacitors (μ-pseudocapacitors). The resulting Ni(OH)2-based devices show several excellent characteristics including high-rate redox activity up to 500 V s-1 and an areal cell capacitance of 16 mF cm-2 corresponding to a volumetric stack capacitance of 325 F cm-3. This volumetric capacitance is two-fold higher than carbon and metal oxide based μ-supercapacitors with interdigitated electrode architecture. Furthermore, these μ-pseudocapacitors show a maximum energy density of 21 mWh cm-3, which is superior to the Li-based thin film batteries. The heterogeneous growth of Ni(OH)2 over the Ni surface during the chemical bath deposition is found to be the key parameter in the formation of uniform monolithic Ni(OH)2 mesoporous nanosheets with vertical orientation, responsible for the remarkable properties of the fabricated devices. Additionally, functional tandem configurations of the μ-pseudocapacitors are shown to be capable of powering a light-emitting diode.

  6. Predicting Soil-Water Characteristics from Volumetric Contents of Pore-Size Analogue Particle Fractions

    DEFF Research Database (Denmark)

    Naveed, Muhammad; Møldrup, Per; Tuller, Markus

    (organic matter, clay, silt, fine and coarse sand), variably included in the model depending on the pF value. The volumetric content of a particular soil particle size fraction was included in the model if it was assumed to contribute to the pore size fraction still occupied with water at the given p......F value. Hereby, the Xw*-model implicitly assumes that a given particle size fraction creates an analogue pore size fraction and, also, is based on the validity of the well-known capillary law equation relating equivalent drained pore size to the soil-water matric potential. The Xw*-model was found...... and clay). It performed reasonably well for the dry-end (above a pF value of 2.0; pF = log(|Ψ|), where Ψ is the matric potential in cm), but did not do as well closer to saturated conditions. The Xw*-model gives the volumetric water content as a function of volumetric content of particle size fractions...

  7. Improving reservoir volumetric estimations in petroleum resource assessment using discovery process models

    Institute of Scientific and Technical Information of China (English)

    Chen Zhuoheng; Osadetz Kirk G.

    2009-01-01

    The reservoir volumetric approach represents a widely accepted, but flawed method of petroleum play resource calculation.In this paper, we propose a combination of techniques that can improve the applicability and quality of the resource estimation.These techniques include: 1) the use of the Multivariate Discovery Process model (MDP) to derive unbiased distribution parameters of reservoir volumetric variables and to reveal correlations among the variables; 2) the use of the Geo-anchored method to estimate simultaneously the number of oil and gas pools in the same play; and 3) the cross-validation of assessment results from different methods.These techniques are illustrated by using an example of crude oil and natural gas resource assessment of the Sverdrup Basin, Canadian Archipelago.The example shows that when direct volumetric measurements of the untested prospects are not available, the MDP model can help derive unbiased estimates of the distribution parameters by using information from the discovered oil and gas accumulations.It also shows that an estimation of the number of oil and gas accumulations and associated size ranges from a discovery process model can provide an alternative and efficient approach when inadequate geological data hinder the estimation.Cross-examination of assessment results derived using different methods allows one to focus on and analyze the causes for the major differences, thus providing a more reliable assessment outcome.

  8. The importance of accurate anatomic assessment for the volumetric analysis of the amygdala

    Directory of Open Access Journals (Sweden)

    L. Bonilha

    2005-03-01

    Full Text Available There is a wide range of values reported in volumetric studies of the amygdala. The use of single plane thick magnetic resonance imaging (MRI may prevent the correct visualization of anatomic landmarks and yield imprecise results. To assess whether there is a difference between volumetric analysis of the amygdala performed with single plane MRI 3-mm slices and with multiplanar analysis of MRI 1-mm slices, we studied healthy subjects and patients with temporal lobe epilepsy. We performed manual delineation of the amygdala on T1-weighted inversion recovery, 3-mm coronal slices and manual delineation of the amygdala on three-dimensional volumetric T1-weighted images with 1-mm slice thickness. The data were compared using a dependent t-test. There was a significant difference between the volumes obtained by the coronal plane-based measurements and the volumes obtained by three-dimensional analysis (P < 0.001. An incorrect estimate of the amygdala volume may preclude a correct analysis of the biological effects of alterations in amygdala volume. Three-dimensional analysis is preferred because it is based on more extensive anatomical assessment and the results are similar to those obtained in post-mortem studies.

  9. Volumetric dimensional changes of dental light-cured dimethacrylate resins after sorption of water or ethanol.

    Science.gov (United States)

    Sideridou, Irini D; Karabela, Maria M; Vouvoudi, Evagelia Ch

    2008-08-01

    This study evaluated the influence of water and ethanol sorption on the volumetric dimensional changes of resins prepared by light curing of Bis-GMA, Bis-EMA, UDMA, TEGDMA or D(3)MA. The resin specimens (15mm diameterx1mm height) were immersed in water or ethanol 37+/-1 degrees C for 30 days. Volumetric changes of specimens were obtained via accurate mass measurements using Archimedes principle. The specimens were reconditioned by dry storage in an oven at 37+/-1 degrees C until constant mass was obtained and then immersed in water or ethanol for 30 days. The volumetric changes of specimens were determined and compared to those obtained from the first sorption. Resins showed similar volume increase during the first and second sorptions of water or ethanol. The volume increase due to water absorption is in the following order: poly-TEGDMA>poly-Bis-GMA>poly-UDMA>poly-Bis-EMA>poly-D(3)MA. On the contrary, the order in ethanol is poly-Bis-GMA>poly-UDMA>poly-TEGDMA>poly-Bis-EMA approximately poly-D(3)MA. The volume increase was found to depend linearly on the amount of water or ethanol absorbed. In the choice of monomers for preparation of composite resin matrix the volume increase in the resin after immersion in water or ethanol must be taken into account. Resins of Bis-EMA and D(3)MA showed the lowest values.

  10. Three-dimensional linear and volumetric analysis of maxillary sinus pneumatization

    Directory of Open Access Journals (Sweden)

    Reham M. Hamdy

    2014-05-01

    Full Text Available Considering the anatomical variability related to the maxillary sinus, its intimate relation to the maxillary posterior teeth and because of all the implications that pneumatization may possess, three-dimensional assessment of maxillary sinus pneumatization is of most usefulness. The aim of this study is to analyze the maxillary sinus dimensions both linearly and volumetrically using cone beam computed tomography (CBCT to assess the maxillary sinus pneumatization. Retrospective analysis of 30 maxillary sinuses belonging to 15 patients’ CBCT scans was performed. Linear and volumetric measurements were conducted and statistically analyzed. The maximum craniocaudal extension of the maxillary sinus was located around the 2nd molar in 93% of the sinuses, while the maximum mediolateral and antroposterior extensions of the maxillary sinus were located at the level of root of zygomatic complex in 90% of sinuses. There was a high correlation between the linear measurements of the right and left sides, where the antroposterior extension of the sinus at level of the nasal floor had the largest correlation (0.89. There was also a high correlation between the Simplant and geometric derived maxillary sinus volumes for both right and left sides (0.98 and 0.96, respectively. The relations of the sinus floor can be accurately assessed on the different orthogonal images obtained through 3D CBCT scan. The geometric method offered a much cheaper, easier, and less sophisticated substitute; therefore, with the availability of software, 3D volumetric measurements are more facilitated.

  11. Dental volumetric tomographical evaluation of location and prevalence of maxillary sinus septa

    Directory of Open Access Journals (Sweden)

    Ibrahim Damlar

    2013-06-01

    Full Text Available Purpose: The aim of this study was to determine the prevalence and location of maxillary sinus septa with the help of dental volumetric tomography. Methods: 760 patients’ 1520 maxillary sinus were evaluated by dental volumetric tomography for detecting maxillary sinus septa. Maxillary sinus was divided into 3 zones (anterior, middle and posterior zones while location of the maxillary sinus septa. Results: 47 of maxillary sinus septa existed in the anterior zone (24.7%, 35 of them in the middle zone (18.4% and 108 of them in the posterior region (56.8%. Conclusion: The formation of the maxillary sinus septa was affected by the existence or lack of the teeth. Correct detection of the presence of maxillary sinus septa was important prior to sinus lifting and dental implant surgery. Dental volumetric tomographical evaluation of maxillary sinus septa was more useful for a correct diagnosis and treatment planning. [Cukurova Med J 2013; 38(3.000: 467-474

  12. A new contrast-assisted method in microcirculation volumetric flow assessment

    Science.gov (United States)

    Lu, Sheng-Yi; Chen, Yung-Sheng; Yeh, Chih-Kuang

    2007-03-01

    Microcirculation volumetric flow rate is a significant index in diseases diagnosis and treatment such as diabetes and cancer. In this study, we propose an integrated algorithm to assess microcirculation volumetric flow rate including estimation of blood perfused area and corresponding flow velocity maps based on high frequency destruction/contrast replenishment imaging technique. The perfused area indicates the blood flow regions including capillaries, arterioles and venules. Due to the echo variance changes between ultrasonic contrast agents (UCAs) pre- and post-destruction two images, the perfused area can be estimated by the correlation-based approach. The flow velocity distribution within the perfused area can be estimated by refilling time-intensity curves (TICs) after UCAs destruction. Most studies introduced the rising exponential model proposed by Wei (1998) to fit the TICs. Nevertheless, we found the TICs profile has a great resemblance to sigmoid function in simulations and in vitro experiments results. Good fitting correlation reveals that sigmoid model was more close to actual fact in describing destruction/contrast replenishment phenomenon. We derived that the saddle point of sigmoid model is proportional to blood flow velocity. A strong linear relationship (R = 0.97) between the actual flow velocities (0.4-2.1 mm/s) and the estimated saddle constants was found in M-mode and B-mode flow phantom experiments. Potential applications of this technique include high-resolution volumetric flow rate assessment in small animal tumor and the evaluation of superficial vasculature in clinical studies.

  13. Crumpled Nitrogen-Doped Graphene for Supercapacitors with High Gravimetric and Volumetric Performances.

    Science.gov (United States)

    Wang, Jie; Ding, Bing; Xu, Yunling; Shen, Laifa; Dou, Hui; Zhang, Xiaogang

    2015-10-14

    Graphene is considered a promising electrochemical capacitors electrode material due to its high surface area and high electrical conductivity. However, restacking interactions between graphene nanosheets significantly decrease the ion-accessible surface area and impede electronic and ionic transfer. This would, in turn, severely hinder the realization of high energy density. Herein, we report a strategy for preparation of few-layer graphene material with abundant crumples and high-level nitrogen doping. The two-dimensional graphene nanosheets (CNG) feature high ion-available surface area, excellent electronic and ion transfer properties, and high packing density, permitting the CNG electrode to exhibit excellent electrochemical performance. In ionic liquid electrolyte, the CNG electrode exhibits gravimetric and volumetric capacitances of 128 F g(-1) and 98 F cm(-3), respectively, achieving gravimetric and volumetric energy densities of 56 Wh kg(-1) and 43 Wh L(-1). The preparation strategy described here provides a new approach for developing a graphene-based supercapacitor with high gravimetric and volumetric energy densities.

  14. Fatigue life estimation for different notched specimens based on the volumetric approach

    Directory of Open Access Journals (Sweden)

    Esmaeili F.

    2010-06-01

    Full Text Available In this paper, the effects of notch radius for different notched specimens has been studied on the values of stress concentration factor, notch strength reduction factor, and fatigue life duration of the specimens. The material which has been selected for this investigation is Al 2024T3 . Volumetric approach has been applied to obtain the values of notch strength reduction factor and results have been compared with those obtained from the Neuber and Peterson methods. Load controlled fatigue tests of mentioned specimens have been conducted on the 250kN servo-hydraulic Zwick/Amsler fatigue testing machine with the frequency of 10Hz. The fatigue lives of the specimens have also been predicted based on the available smooth S-N curve of Al2024-T3 and also the amounts of notch strength reduction factor which have been obtained from volumetric, Neuber and Peterson methods. The values of stress and strain around the notch roots are required to predict the fatigue life of notched specimens, so Ansys finite element code has been used and non-linear analyses have been performed to obtain the stress and strain distributions around the notches. The plastic deformations of the material have been simulated using multi-linear kinematic hardening and cyclic stress-strain relation. The work here shows that the volumetric approach does a very good job for predicting the fatigue life of the notched specimens.

  15. Volumetric changes of the graft after maxillary sinus floor augmentation with Bio-Oss and autogenous bone in different ratios

    DEFF Research Database (Denmark)

    Jensen, Thomas; Schou, Søren; Svendsen, Patricia Anne

    2012-01-01

    composition was selected at random and placed concomitant with implant placement. Computed tomographies of the maxillary sinuses were obtained preoperatively, immediately postoperatively, and at euthanasia after 12 weeks. The volumetric changes of the graft were estimated using the Cavalieri principle...

  16. Optimal planning strategy among various arc arrangements for prostate stereotactic body radiotherapy with volumetric modulated arc therapy technique

    Directory of Open Access Journals (Sweden)

    Kang Sang Won

    2017-03-01

    Full Text Available The aim of this study was to determine the optimal strategy among various arc arrangements in prostate plans of stereotactic body radiotherapy with volumetric modulated arc therapy (SBRT-VMAT.

  17. Volumetric Properties of the Mixture Trichloromethane CHCl3 + C4H10O Diethyl ether (VMSD1211, LB3412_V)

    Science.gov (United States)

    Cibulka, I.; Fontaine, J.-C.; Sosnkowska-Kehiaian, K.; Kehiaian, H. V.

    This document is part of Subvolume C 'Binary Liquid Systems of Nonelectrolytes III' of Volume 26 'Heats of Mixing, Vapor-Liquid Equilibrium, and Volumetric Properties of Mixtures and Solutions' of Landolt-Börnstein Group IV 'Physical Chemistry'. It contains the Chapter 'Volumetric Properties of the Mixture Trichloromethane CHCl3 + C4H10O Diethyl ether (VMSD1211, LB3412_V)' providing data from direct low-pressure dilatometric measurement of molar excess volume at variable mole fraction and constant temperature.

  18. Volumetric Properties of the Mixture Trichloromethane CHCl3 + C8H16 Cyclooctane (VMSD1211, LB3565_V)

    Science.gov (United States)

    Cibulka, I.; Fontaine, J.-C.; Sosnkowska-Kehiaian, K.; Kehiaian, H. V.

    This document is part of Subvolume B 'Binary Liquid Systems of Nonelectrolytes II' of Volume 26 'Heats of Mixing, Vapor-Liquid Equilibrium, and Volumetric Properties of Mixtures and Solutions' of Landolt-Börnstein Group IV 'Physical Chemistry'. It contains the Chapter 'Volumetric Properties of the Mixture Trichloromethane CHCl3 + C8H16 Cyclooctane (VMSD1211, LB3565_V)' providing data from direct low-pressure dilatometric measurement of molar excess volume at variable mole fraction and constant temperature.

  19. Volumetric Properties of the Mixture Trichloromethane CHCl3 + C5H10O Oxane (VMSD1212, LB3577_V)

    Science.gov (United States)

    Cibulka, I.; Fontaine, J.-C.; Sosnkowska-Kehiaian, K.; Kehiaian, H. V.

    This document is part of Subvolume C 'Binary Liquid Systems of Nonelectrolytes III' of Volume 26 'Heats of Mixing, Vapor-Liquid Equilibrium, and Volumetric Properties of Mixtures and Solutions' of Landolt-Börnstein Group IV 'Physical Chemistry'. It contains the Chapter 'Volumetric Properties of the Mixture Trichloromethane CHCl3 + C5H10O Oxane (VMSD1212, LB3577_V)' providing data by calculation of molar excess volume from low-pressure density measurements at variable mole fraction and constant temperature.

  20. Volumetric Properties of the Mixture Trichloromethane CHCl3 + C4H8O Oxolane (VMSD1212, LB3576_V)

    Science.gov (United States)

    Cibulka, I.; Fontaine, J.-C.; Sosnkowska-Kehiaian, K.; Kehiaian, H. V.

    This document is part of Subvolume C 'Binary Liquid Systems of Nonelectrolytes III' of Volume 26 'Heats of Mixing, Vapor-Liquid Equilibrium, and Volumetric Properties of Mixtures and Solutions' of Landolt-Börnstein Group IV 'Physical Chemistry'. It contains the Chapter 'Volumetric Properties of the Mixture Trichloromethane CHCl3 + C4H8O Oxolane (VMSD1212, LB3576_V)' providing data by calculation of molar excess volume from low-pressure density measurements at variable mole fraction and constant temperature.

  1. Volumetric Properties of the Mixture Trichloromethane CHCl3 + C6H14 Hexane (VMSD1211, LB4339_V)

    Science.gov (United States)

    Cibulka, I.; Fontaine, J.-C.; Sosnkowska-Kehiaian, K.; Kehiaian, H. V.

    This document is part of Subvolume B 'Binary Liquid Systems of Nonelectrolytes II' of Volume 26 'Heats of Mixing, Vapor-Liquid Equilibrium, and Volumetric Properties of Mixtures and Solutions' of Landolt-Börnstein Group IV 'Physical Chemistry'. It contains the Chapter 'Volumetric Properties of the Mixture Trichloromethane CHCl3 + C6H14 Hexane (VMSD1211, LB4339_V)' providing data from direct low-pressure dilatometric measurement of molar excess volume at variable mole fraction and constant temperature.

  2. Volumetric Properties of the Mixture Trichloromethane CHCl3 + C6H12 Cyclohexane (VMSD1211, LB3566_V)

    Science.gov (United States)

    Cibulka, I.; Fontaine, J.-C.; Sosnkowska-Kehiaian, K.; Kehiaian, H. V.

    This document is part of Subvolume A 'Binary Liquid Systems of Nonelectrolytes I' of Volume 26 'Heats of Mixing, Vapor-Liquid Equilibrium, and Volumetric Properties of Mixtures and Solutions' of Landolt-Börnstein Group IV 'Physical Chemistry'. It contains the Chapter 'Volumetric Properties of the Mixture Trichloromethane CHCl3 + C6H12 Cyclohexane (VMSD1211, LB3566_V)' providing data from direct low-pressure dilatometric measurement of molar excess volume at variable mole fraction and constant temperature.

  3. Volumetric Properties of the Mixture Trichloromethane CHCl3 + C6H7N Aniline (VMSD1211, LB4340_V)

    Science.gov (United States)

    Cibulka, I.; Fontaine, J.-C.; Sosnkowska-Kehiaian, K.; Kehiaian, H. V.

    This document is part of Subvolume C 'Binary Liquid Systems of Nonelectrolytes III' of Volume 26 'Heats of Mixing, Vapor-Liquid Equilibrium, and Volumetric Properties of Mixtures and Solutions' of Landolt-Börnstein Group IV 'Physical Chemistry'. It contains the Chapter 'Volumetric Properties of the Mixture Trichloromethane CHCl3 + C6H7N Aniline (VMSD1211, LB4340_V)' providing data from direct low-pressure dilatometric measurement of molar excess volume at variable mole fraction and constant temperature.

  4. Volumetric Properties of the Mixture Trichloromethane CHCl3 + C5H10 Cyclopentane (VMSD1211, LB3567_V)

    Science.gov (United States)

    Cibulka, I.; Fontaine, J.-C.; Sosnkowska-Kehiaian, K.; Kehiaian, H. V.

    This document is part of Subvolume A 'Binary Liquid Systems of Nonelectrolytes I' of Volume 26 'Heats of Mixing, Vapor-Liquid Equilibrium, and Volumetric Properties of Mixtures and Solutions' of Landolt-Börnstein Group IV 'Physical Chemistry'. It contains the Chapter 'Volumetric Properties of the Mixture Trichloromethane CHCl3 + C5H10 Cyclopentane (VMSD1211, LB3567_V)' providing data from direct low-pressure dilatometric measurement of molar excess volume at variable mole fraction and constant temperature.

  5. Volumetric Properties of the Mixture Trichloromethane CHCl3 + C2H6S 2-Thiapropane (VMSD1211, LB3233_V)

    Science.gov (United States)

    Cibulka, I.; Fontaine, J.-C.; Sosnkowska-Kehiaian, K.; Kehiaian, H. V.

    This document is part of Subvolume C 'Binary Liquid Systems of Nonelectrolytes III' of Volume 26 'Heats of Mixing, Vapor-Liquid Equilibrium, and Volumetric Properties of Mixtures and Solutions' of Landolt-Börnstein Group IV 'Physical Chemistry'. It contains the Chapter 'Volumetric Properties of the Mixture Trichloromethane CHCl3 + C2H6S 2-Thiapropane (VMSD1211, LB3233_V)' providing data from direct low-pressure dilatometric measurement of molar excess volume at variable mole fraction and constant temperature.

  6. Volumetric Properties of the Mixture Trichloromethane CHCl3 + C2H6OS Dimethyl sulfoxide (VMSD1211, LB3256_V)

    Science.gov (United States)

    Cibulka, I.; Fontaine, J.-C.; Sosnkowska-Kehiaian, K.; Kehiaian, H. V.

    This document is part of Subvolume C 'Binary Liquid Systems of Nonelectrolytes III' of Volume 26 'Heats of Mixing, Vapor-Liquid Equilibrium, and Volumetric Properties of Mixtures and Solutions' of Landolt-Börnstein Group IV 'Physical Chemistry'. It contains the Chapter 'Volumetric Properties of the Mixture Trichloromethane CHCl3 + C2H6OS Dimethyl sulfoxide (VMSD1211, LB3256_V)' providing data from direct low-pressure dilatometric measurement of molar excess volume at variable mole fraction and constant temperature.

  7. Volumetric Properties of the Mixture Trichloromethane CHCl3 + CH2Cl2 Dichloromethane (VMSD1212, LB4574_V)

    Science.gov (United States)

    Cibulka, I.; Fontaine, J.-C.; Sosnkowska-Kehiaian, K.; Kehiaian, H. V.

    This document is part of Subvolume A 'Binary Liquid Systems of Nonelectrolytes I' of Volume 26 'Heats of Mixing, Vapor-Liquid Equilibrium, and Volumetric Properties of Mixtures and Solutions' of Landolt-Börnstein Group IV 'Physical Chemistry'. It contains the Chapter 'Volumetric Properties of the Mixture Trichloromethane CHCl3 + CH2Cl2 Dichloromethane (VMSD1212, LB4574_V)' providing data by calculation of molar excess volume from low-pressure density measurements at variable mole fraction and constant temperature.

  8. Volumetric Properties of the Mixture Trichloromethane CHCl3 + C6H6 Benzene (VMSD1212, LB3207_V)

    Science.gov (United States)

    Cibulka, I.; Fontaine, J.-C.; Sosnkowska-Kehiaian, K.; Kehiaian, H. V.

    This document is part of Subvolume A 'Binary Liquid Systems of Nonelectrolytes I' of Volume 26 'Heats of Mixing, Vapor-Liquid Equilibrium, and Volumetric Properties of Mixtures and Solutions' of Landolt-Börnstein Group IV 'Physical Chemistry'. It contains the Chapter 'Volumetric Properties of the Mixture Trichloromethane CHCl3 + C6H6 Benzene (VMSD1212, LB3207_V)' providing data by calculation of molar excess volume from low-pressure density measurements at variable mole fraction and constant temperature.

  9. Volumetric Properties of the Mixture Trichloromethane CHCl3 + C2H3N Ethanenitrile (VMSD1212, LB4352_V)

    Science.gov (United States)

    Cibulka, I.; Fontaine, J.-C.; Sosnkowska-Kehiaian, K.; Kehiaian, H. V.

    This document is part of Subvolume C 'Binary Liquid Systems of Nonelectrolytes III' of Volume 26 'Heats of Mixing, Vapor-Liquid Equilibrium, and Volumetric Properties of Mixtures and Solutions' of Landolt-Börnstein Group IV 'Physical Chemistry'. It contains the Chapter 'Volumetric Properties of the Mixture Trichloromethane CHCl3 + C2H3N Ethanenitrile (VMSD1212, LB4352_V)' providing data by calculation of molar excess volume from low-pressure density measurements at variable mole fraction and constant temperature.

  10. Volumetric Properties of the Mixture Trichloromethane CHCl3 + C4H10S 3-Thiapentane (VMSD1211, LB3237_V)

    Science.gov (United States)

    Cibulka, I.; Fontaine, J.-C.; Sosnkowska-Kehiaian, K.; Kehiaian, H. V.

    This document is part of Subvolume C 'Binary Liquid Systems of Nonelectrolytes III' of Volume 26 'Heats of Mixing, Vapor-Liquid Equilibrium, and Volumetric Properties of Mixtures and Solutions' of Landolt-Börnstein Group IV 'Physical Chemistry'. It contains the Chapter 'Volumetric Properties of the Mixture Trichloromethane CHCl3 + C4H10S 3-Thiapentane (VMSD1211, LB3237_V)' providing data from direct low-pressure dilatometric measurement of molar excess volume at variable mole fraction and constant temperature.

  11. 1-D diffusion based solidification model with volumetric expansion and shrinkage effect: A semi-analytical approach

    Science.gov (United States)

    Monde, Aniket D.; Chakraborty, Prodyut R.

    2017-10-01

    Volumetric expansion and shrinkage due to different densities of solid and liquid phases are common phenomena during solidification process. Simple analytical models addressing effect of volumetric expansion/shrinkage during solidification are rarely found. The few existing 1-D solidification models are valid only for semi-infinite domain with limitations of their application for finite domain size. The focus of the present work is to develop a 1-D semi-analytical solidification model addressing effects of volumetric expansion/shrinkage in a finite domain. The proposed semi-analytical scheme involves finding simultaneous solution of transient 1-D heat diffusion equations at solid and liquid domain coupled at the interface by Stefan condition. The change of the total domain length during solidification due to volumetric expansion/shrinkage is addressed by using mass conservation. For validation of the proposed model, solidification of water in a finite domain is studied without considering volumetric expansion/shrinkage effect and results are compared with those obtained from existing enthalpy updating based numerical model. After validation, case studies pertaining to volumetric expansion and shrinkage are performed considering solidification of water and paraffin respectively and physically consistent results are obtained. The study is relevant for understanding unidirectional crystal growth under the effect of controlled boundary condition.

  12. Area and volumetric density estimation in processed full-field digital mammograms for risk assessment of breast cancer.

    Directory of Open Access Journals (Sweden)

    Abbas Cheddad

    Full Text Available INTRODUCTION: Mammographic density, the white radiolucent part of a mammogram, is a marker of breast cancer risk and mammographic sensitivity. There are several means of measuring mammographic density, among which are area-based and volumetric-based approaches. Current volumetric methods use only unprocessed, raw mammograms, which is a problematic restriction since such raw mammograms are normally not stored. We describe fully automated methods for measuring both area and volumetric mammographic density from processed images. METHODS: The data set used in this study comprises raw and processed images of the same view from 1462 women. We developed two algorithms for processed images, an automated area-based approach (CASAM-Area and a volumetric-based approach (CASAM-Vol. The latter method was based on training a random forest prediction model with image statistical features as predictors, against a volumetric measure, Volpara, for corresponding raw images. We contrast the three methods, CASAM-Area, CASAM-Vol and Volpara directly and in terms of association with breast cancer risk and a known genetic variant for mammographic density and breast cancer, rs10995190 in the gene ZNF365. Associations with breast cancer risk were evaluated using images from 47 breast cancer cases and 1011 control subjects. The genetic association analysis was based on 1011 control subjects. RESULTS: All three measures of mammographic density were associated with breast cancer risk and rs10995190 (p0.10 for risk, p>0.03 for rs10995190. CONCLUSIONS: Our results show that it is possible to obtain reliable automated measures of volumetric and area mammographic density from processed digital images. Area and volumetric measures of density on processed digital images performed similar in terms of risk and genetic association.

  13. Characterization of three dimensional volumetric strain distribution during passive tension of the human tibialis anterior using Cine Phase Contrast MRI.

    Science.gov (United States)

    Jensen, Elisabeth R; Morrow, Duane A; Felmlee, Joel P; Murthy, Naveen S; Kaufman, Kenton R

    2016-10-03

    Intramuscular pressure correlates strongly with muscle tension and is a promising tool for quantifying individual muscle force. However, clinical application is impeded by measurement variability that is not fully understood. Previous studies point to regional differences in IMP, specifically increasing pressure with muscle depth. Based on conservation of mass, intramuscular pressure and volumetric strain distributions may be inversely related. Therefore, we hypothesized volumetric strain would decrease with muscle depth. To test this we quantified 3D volumetric strain in the tibialis anterior of 12 healthy subjects using Cine Phase Contrast Magnetic Resonance Imaging. Cine Phase Contrast data were collected while a custom apparatus rotated the subjects' ankle continuously between neutral and plantarflexion. A T2-weighted image stack was used to define the resting tibials anterior position. Custom and commercial post-processing software were used to quantify the volumetric strain distribution. To characterize regional strain changes, the muscle was divided into superior-inferior sections and either medial-lateral or anterior-posterior slices. Mean volumetric strain was compared across the sections and slices. As hypothesized, volumetric strain demonstrated regional differences with a decreasing trend from the anterior (superficial) to the posterior (deep) muscle regions. Statistical tests showed significant main effects and interactions of superior-inferior and anterior-posterior position as well as superior-inferior and medial-lateral position on regional strain. These data support our hypothesis and imply a potential relationship between regional volumetric strain and intramuscular pressure. This finding may advance our understanding of intramuscular pressure variability sources and lead to more reliable measurement solutions in the future. Copyright © 2016 Elsevier Ltd. All rights reserved.

  14. Volumetric intake flow measurements of an IC engine using magnetic resonance velocimetry

    Science.gov (United States)

    Freudenhammer, Daniel; Baum, Elias; Peterson, Brian; Böhm, Benjamin; Jung, Bernd; Grundmann, Sven

    2014-05-01

    Magnetic resonance velocimetry (MRV) measurements are performed in a 1:1 scale model of a single-cylinder optical engine to investigate the volumetric flow within the intake and cylinder geometry during flow induction. The model is a steady flow water analogue of the optical IC-engine with a fixed valve lift of mm to simulate the induction flow at crank-angle bTDC. This setup resembles a steady flow engine test bench configuration. MRV measurements are validated with phase-averaged particle image velocimetry (PIV) measurements performed within the symmetry plane of the optical engine. Differences in experimental operating parameters between MRV and PIV measurements are well addressed. Comparison of MRV and PIV measurements is demonstrated using normalized mean velocity component profiles and showed excellent agreement in the upper portion of the cylinder chamber (i.e., mm). MRV measurements are further used to analyze the ensemble average volumetric flow within the 3D engine domain. Measurements are used to describe the 3D overflow and underflow behavior as the annular flow enters the cylinder chamber. Flow features such as the annular jet-like flows extending into the cylinder, their influence on large-scale in-cylinder flow motion, as well as flow recirculation zones are identified in 3D space. Inlet flow velocities are analyzed around the entire valve curtain perimeter to quantify percent mass flow rate entering the cylinder. Recirculation zones associated with the underflow are shown to reduce local mass flow rates up to 50 %. Recirculation zones are further analyzed in 3D space within the intake manifold and cylinder chamber. It is suggested that such recirculation zones can have large implications on cylinder charge filling and variations of the in-cylinder flow pattern. MRV is revealed to be an important diagnostic tool used to understand the volumetric induction flow within engine geometries and is potentially suited to evaluate flow changes due to intake

  15. Using on-site liver 3-D reconstruction and volumetric calculations in split liver transplantation

    Institute of Scientific and Technical Information of China (English)

    Trevor W Reichman; Brittan Y Fiorello; Ian Carmody; Humberto Bohorquez; Ari Cohen; John Seal; David Bruce; George E Loss

    2016-01-01

    BACKGROUND: Split liver transplantation increases the number of grafts available for transplantation. Pre-recovery assessment of liver graft volume is essential for selecting suit-able recipients. The purpose of this study was to determine the ability and feasibility of constructing a 3-D model to aid in surgical planning and to predict graft weight prior to anin situ division of the donor liver. METHODS: Over 11 months, 3-D volumetric reconstruction of 4 deceased donors was performed using Pathifnder Scout© liver volumetric software. Demographic, laboratory, operative, perioperative and survival data for these patients along with donor demographic data were collected prospectively and analyzed retrospectively. RESULTS: The average predicted weight of the grafts from the adult donors obtained from anin situ split procedure were 1130 g (930-1458 g) for the extended right lobe donors and 312 g (222-396 g) for left lateral segment grafts. Actual adult graft weight was 92% of the predicted weight for both the ex-tended right grafts and the left lateral segment grafts. The pre-dicted and actual graft weights for the pediatric donors were 176 g and 210 g for the left lateral segment grafts and 308 g and 280 g for the extended right lobe grafts, respectively. All grafts were transplanted except for the right lobe from the pediatric donors due to the small graft weight. CONCLUSIONS: On-site volumetric assessment of donors provides useful information for the planning of anin situ split and for selection of recipients. This information may expand the donor pool to recipients previously felt to be unsuitable due to donor and/or recipient weight.

  16. Disorder-specific volumetric brain difference in adolescent major depressive disorder and bipolar depression.

    Science.gov (United States)

    MacMaster, Frank P; Carrey, Normand; Langevin, Lisa Marie; Jaworska, Natalia; Crawford, Susan

    2014-03-01

    Structural abnormalities in frontal, limbic and subcortical regions have been noted in adults with both major depressive disorder (MDD) and bipolar disorder (BD). In the current study, we examined regional brain morphology in youth with MDD and BD as compared to controls. Regional brain volumes were measured in 32 MDD subjects (15.7 ± 2.1 years), 14 BD subjects (16.0 ± 2.4 years) and 22 healthy controls (16.0 ± 2.8 years) using magnetic resonance imaging (MRI). Regions of interest included the hippocampus, dorsolateral prefrontal cortex (DLPFC), anterior cingulate cortex (ACC), caudate, putamen and thalamus. Volumetric differences between groups were significant (F26,80 = 1.80, p = 0.02). Post-hoc analyses indicated that individuals with MDD showed reduced left hippocampus volumes (p = 0.048) as well as right ACC white and gray matter volumes (p = 0.003; p = 0.01) compared to controls. BD participants also displayed reduced left hippocampal and right/left putamen volumes compared to controls (p < 0.001; p = 0.015; p = 0.046 respectively). Interestingly, right and left ACC white matter volumes were smaller in MDD than in BD participants (p = 0.019; p = 0.045 respectively). No volumetric group differences were observed for the DLPFC and thalamus. Discriminant analysis was able to correctly classify 81.0 % of subjects as having BD or as MDD based on imaging data. Confirmation and extension of our findings requires larger sample sizes. Our findings provide new evidence of distinct, specific regional brain volumetric differences between MDD and BD that may be used to distinguish the two disorders.

  17. Evaluation of feature-based 3-d registration of probabilistic volumetric scenes

    Science.gov (United States)

    Restrepo, Maria I.; Ulusoy, Ali O.; Mundy, Joseph L.

    2014-12-01

    Automatic estimation of the world surfaces from aerial images has seen much attention and progress in recent years. Among current modeling technologies, probabilistic volumetric models (PVMs) have evolved as an alternative representation that can learn geometry and appearance in a dense and probabilistic manner. Recent progress, in terms of storage and speed, achieved in the area of volumetric modeling, opens the opportunity to develop new frameworks that make use of the PVM to pursue the ultimate goal of creating an entire map of the earth, where one can reason about the semantics and dynamics of the 3-d world. Aligning 3-d models collected at different time-instances constitutes an important step for successful fusion of large spatio-temporal information. This paper evaluates how effectively probabilistic volumetric models can be aligned using robust feature-matching techniques, while considering different scenarios that reflect the kind of variability observed across aerial video collections from different time instances. More precisely, this work investigates variability in terms of discretization, resolution and sampling density, errors in the camera orientation, and changes in illumination and geographic characteristics. All results are given for large-scale, outdoor sites. In order to facilitate the comparison of the registration performance of PVMs to that of other 3-d reconstruction techniques, the registration pipeline is also carried out using Patch-based Multi-View Stereo (PMVS) algorithm. Registration performance is similar for scenes that have favorable geometry and the appearance characteristics necessary for high quality reconstruction. In scenes containing trees, such as a park, or many buildings, such as a city center, registration performance is significantly more accurate when using the PVM.

  18. A Multicenter Study of Volumetric Computed Tomography for Staging Malignant Pleural Mesothelioma.

    Science.gov (United States)

    Rusch, Valerie W; Gill, Ritu; Mitchell, Alan; Naidich, David; Rice, David C; Pass, Harvey I; Kindler, Hedy L; De Perrot, Marc; Friedberg, Joseph

    2016-10-01

    Standard imaging modalities are inaccurate in staging malignant pleural mesothelioma (MPM). Single-institution studies suggest that volumetric computed tomography (CT) is more accurate but labor intensive. We established a multicenter network to test interobserver variability, accuracy (relative to pathologic stage), and the prognostic significance of semiautomated volumetric CT. Six institutions electronically submitted to an established multicenter database clinical and pathologic data for patients with MPM who had operations. Institutional radiologists reviewed preoperative CT scans for quality and then submitted by electronic network (AG Mednet, www.agmednet.com) to the biostatistical center. Two reference radiologists blinded to clinical data performed semiautomated tumor volume calculations using Vitrea Enterprise 6.0 software (Vital Images, Minnetonka, MN) and then submitted readings to the biostatistical center. Study end points included feasibility of the network, interobserver variability for volumetric CT, correlation of tumor volume to pTN stages, and overall survival (OS). Of 164 patients, the CT scans for 129 were analyzable and read by reference radiologists. Most tumors were less than 500 cm(3). A small bias was observed between readers because one provided consistently larger measurements than the other (mean difference, 47.9; p = .0027), but for 80%, the absolute difference was 200 cm(3) or less. Spearman correlation between readers was 0.822. Volume correlated with pTN stages and OS, best defined by three groups with average volumes of 91.2, 245.3, and 511.3 cm(3) associated with median OS of 37, 18, and 8 months, respectively. For the first time, a multicenter network was established and initial correlations of tumor volume with pTN stages and OS are shown. A larger multicenter international study is planned to confirm the results and refine correlations. Copyright © 2016 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights

  19. Somatic mutations associated with MRI-derived volumetric features in glioblastoma

    Energy Technology Data Exchange (ETDEWEB)

    Gutman, David A.; Dunn, William D. [Emory University School of Medicine, Departments of Neurology, Atlanta, GA (United States); Emory University School of Medicine, Biomedical Informatics, Atlanta, GA (United States); Grossmann, Patrick; Alexander, Brian M. [Harvard Medical School, Department of Radiation Oncology, Dana-Farber Cancer Institute, Brigham and Women' s Hospital, Boston, MA (United States); Cooper, Lee A.D. [Emory University School of Medicine, Biomedical Informatics, Atlanta, GA (United States); Georgia Institute of Technology, Department of Biomedical Engineering, Atlanta, GA (United States); Holder, Chad A. [Emory University School of Medicine, Radiology and Imaging Sciences, Atlanta, GA (United States); Ligon, Keith L. [Brigham and Women' s Hospital, Harvard Medical School, Pathology, Dana-Farber Cancer Institute, Boston, MA (United States); Aerts, Hugo J.W.L. [Harvard Medical School, Department of Radiation Oncology, Dana-Farber Cancer Institute, Brigham and Women' s Hospital, Boston, MA (United States); Brigham and Women' s Hospital, Harvard Medical School, Radiology, Dana-Farber Cancer Institute, Boston, MA (United States)

    2015-12-15

    MR imaging can noninvasively visualize tumor phenotype characteristics at the macroscopic level. Here, we investigated whether somatic mutations are associated with and can be predicted by MRI-derived tumor imaging features of glioblastoma (GBM). Seventy-six GBM patients were identified from The Cancer Imaging Archive for whom preoperative T1-contrast (T1C) and T2-FLAIR MR images were available. For each tumor, a set of volumetric imaging features and their ratios were measured, including necrosis, contrast enhancing, and edema volumes. Imaging genomics analysis assessed the association of these features with mutation status of nine genes frequently altered in adult GBM. Finally, area under the curve (AUC) analysis was conducted to evaluate the predictive performance of imaging features for mutational status. Our results demonstrate that MR imaging features are strongly associated with mutation status. For example, TP53-mutated tumors had significantly smaller contrast enhancing and necrosis volumes (p = 0.012 and 0.017, respectively) and RB1-mutated tumors had significantly smaller edema volumes (p = 0.015) compared to wild-type tumors. MRI volumetric features were also found to significantly predict mutational status. For example, AUC analysis results indicated that TP53, RB1, NF1, EGFR, and PDGFRA mutations could each be significantly predicted by at least one imaging feature. MRI-derived volumetric features are significantly associated with and predictive of several cancer-relevant, drug-targetable DNA mutations in glioblastoma. These results may shed insight into unique growth characteristics of individual tumors at the macroscopic level resulting from molecular events as well as increase the use of noninvasive imaging in personalized medicine. (orig.)

  20. Heritability of volumetric brain changes and height in children entering puberty.

    Science.gov (United States)

    van Soelen, Inge L C; Brouwer, Rachel M; van Baal, G Caroline M; Schnack, Hugo G; Peper, Jiska S; Chen, Lei; Kahn, René S; Boomsma, Dorret I; Hulshoff Pol, Hilleke E

    2013-03-01

    The human brain undergoes structural changes in children entering puberty, while simultaneously children increase in height. It is not known if brain changes are under genetic control, and whether they are related to genetic factors influencing the amount of overall increase in height. Twins underwent magnetic resonance imaging brain scans at age 9 (N = 190) and 12 (N = 125). High heritability estimates were found at both ages for height and brain volumes (49-96%), and high genetic correlation between ages were observed (r(g) > 0.89). With increasing age, whole brain (+1.1%), cerebellum (+4.2%), cerebral white matter (+5.1%), and lateral ventricle (+9.4%) volumes increased, and third ventricle (-4.0%) and cerebral gray matter (-1.6%) volumes decreased. Children increased on average 13.8 cm in height (9.9%). Genetic influences on individual difference in volumetric brain and height changes were estimated, both within and across traits. The same genetic factors influenced both cerebral (20% heritable) and cerebellar volumetric changes (45%). Thus, the extent to which changes in cerebral and cerebellar volumes are heritable in children entering puberty are due to the same genes that influence change in both structures. The increase in height was heritable (73%), and not associated with cerebral volumetric change, but positively associated with cerebellar volume change (r(p) = 0.24). This association was explained by a genetic correlation (r(g) = 0.48) between height and cerebellar change. Brain and body each expand at their own pace and through separate genetic pathways. There are distinct genetic processes acting on structural brain development, which cannot be explained by genetic increase in height.

  1. The importance of volumetric canopy morphology when modelling drag around riparian vegetation

    Science.gov (United States)

    Boothroyd, Richard; Hardy, Richard; Warburton, Jeff; Marjoribanks, Timothy

    2017-04-01

    Riparian vegetation has a significant impact on the hydraulic functioning of river systems. The bulk of past work concerned with modelling the influence of vegetation on flow has considered vegetation to be morphologically simple, and has generally neglected the complexity and porosity of natural plants, defined herein as the volumetric canopy morphology. However, the volumetric canopy morphology can influence the mean and turbulent properties of the flow, producing spatially heterogeneous downstream velocity fields. By explicitly accounting for this in a computational fluid dynamics (CFD) model, and representing the plant as a porous blockage, complex flow structures and drag can be modelled. For a riparian species, Hebe odora, good agreement with flume measurements are found. Plant shear layer turbulence is shown to be dominated by Kelvin-Helmholtz and Görtler-type vortices, generated through shear instability. Porous representations of the plants, that allow for flow to pass through the plant canopy interior, are compared against fully impermeable plant representations. Penetration of fluid through the canopy in the porous case resembles 'bleed-flow', and this results in a plant wake region that significantly differs from the impermeable case, which is characteristic of wake flow around a traditional bluff body. These results demonstrate the significant effect that the volumetric canopy morphology and porosity of natural plants has on the three-dimensional flow and in-stream drag, and enables a re-evaluation of vegetative flow resistance. The modelled results allow a species dependent Manning's n to be calculated, and this presents an opportunity to move away from the conventional methods of representing vegetation in hydraulic models, in favour of a more physically determined approach. Given the importance of vegetation in river corridor management, and the increasing application of UAV imagery to map riparian vegetation, the numerical scheme developed here

  2. MTF analysis of a prototype table-top inverse-geometry volumetric CT system

    Science.gov (United States)

    Schmidt, Taly G.; Bennett, N. Robert; Mazin, Samuel R.; Star-Lack, Josh; Solomon, Edward G.; Pelc, Norbert J.

    2005-04-01

    This work investigates the modulation transfer function (MTF) of a prototype table-top inverse-geometry volumetric CT (IGCT) system. The IGCT system has been proposed to acquire sufficient volumetric data in one circular rotation using a large-area scanned source and a narrower array of fast detectors. The source and detector arrays have the same axial, or slice, extent, thus providing sufficient volumetric coverage. A prototype system has been built using a NexRay Scanning-Beam Digital X-ray system (NexRay, Inc., Los Gatos, CA) with the C-arm gantry in the horizontal position and a stage placed between the source and detector to rotate the scanned object. The resulting system has a 16-cm in-plane field of view (FOV) and 5-cm axial FOV. Two phantoms were constructed for measuring the MTF. A 76 micron tungsten wire placed axially in a plastic frame was used to measure the in-plane MTF, and the same wire slanted at 45 degrees was used to test the isotropy of the MTF. The data were calibrated for flat-field intensity and geometric misalignment and reconstructed using a modified 3D PET algorithm. For both phantoms, slices perpendicular to the wires were reconstructed. Simulations which model the IGCT system were used to verify the MTF measurement, along with analytical predictions. The measured MTF curve was similar in shape to the predicted curve with a 10% point at 20 lp/cm compared to a predicted 18 lp/cm. Future work will also study the uniformity of the MTF across the FOV and further characterize the IGCT system.

  3. Conductive two-dimensional titanium carbide `clay' with high volumetric capacitance

    Science.gov (United States)

    Ghidiu, Michael; Lukatskaya, Maria R.; Zhao, Meng-Qiang; Gogotsi, Yury; Barsoum, Michel W.

    2014-12-01

    Safe and powerful energy storage devices are becoming increasingly important. Charging times of seconds to minutes, with power densities exceeding those of batteries, can in principle be provided by electrochemical capacitors--in particular, pseudocapacitors. Recent research has focused mainly on improving the gravimetric performance of the electrodes of such systems, but for portable electronics and vehicles volume is at a premium. The best volumetric capacitances of carbon-based electrodes are around 300 farads per cubic centimetre; hydrated ruthenium oxide can reach capacitances of 1,000 to 1,500 farads per cubic centimetre with great cyclability, but only in thin films. Recently, electrodes made of two-dimensional titanium carbide (Ti3C2, a member of the `MXene' family), produced by etching aluminium from titanium aluminium carbide (Ti3AlC2, a `MAX' phase) in concentrated hydrofluoric acid, have been shown to have volumetric capacitances of over 300 farads per cubic centimetre. Here we report a method of producing this material using a solution of lithium fluoride and hydrochloric acid. The resulting hydrophilic material swells in volume when hydrated, and can be shaped like clay and dried into a highly conductive solid or rolled into films tens of micrometres thick. Additive-free films of this titanium carbide `clay' have volumetric capacitances of up to 900 farads per cubic centimetre, with excellent cyclability and rate performances. This capacitance is almost twice that of our previous report, and our synthetic method also offers a much faster route to film production as well as the avoidance of handling hazardous concentrated hydrofluoric acid.

  4. Conductive two-dimensional titanium carbide 'clay' with high volumetric capacitance.

    Science.gov (United States)

    Ghidiu, Michael; Lukatskaya, Maria R; Zhao, Meng-Qiang; Gogotsi, Yury; Barsoum, Michel W

    2014-12-04

    Safe and powerful energy storage devices are becoming increasingly important. Charging times of seconds to minutes, with power densities exceeding those of batteries, can in principle be provided by electrochemical capacitors--in particular, pseudocapacitors. Recent research has focused mainly on improving the gravimetric performance of the electrodes of such systems, but for portable electronics and vehicles volume is at a premium. The best volumetric capacitances of carbon-based electrodes are around 300 farads per cubic centimetre; hydrated ruthenium oxide can reach capacitances of 1,000 to 1,500 farads per cubic centimetre with great cyclability, but only in thin films. Recently, electrodes made of two-dimensional titanium carbide (Ti3C2, a member of the 'MXene' family), produced by etching aluminium from titanium aluminium carbide (Ti3AlC2, a 'MAX' phase) in concentrated hydrofluoric acid, have been shown to have volumetric capacitances of over 300 farads per cubic centimetre. Here we report a method of producing this material using a solution of lithium fluoride and hydrochloric acid. The resulting hydrophilic material swells in volume when hydrated, and can be shaped like clay and dried into a highly conductive solid or rolled into films tens of micrometres thick. Additive-free films of this titanium carbide 'clay' have volumetric capacitances of up to 900 farads per cubic centimetre, with excellent cyclability and rate performances. This capacitance is almost twice that of our previous report, and our synthetic method also offers a much faster route to film production as well as the avoidance of handling hazardous concentrated hydrofluoric acid.

  5. Cerebrospinal fluid volumetric MRI mapping as a simple measurement for evaluating brain atrophy.

    Science.gov (United States)

    De Vis, J B; Zwanenburg, J J; van der Kleij, L A; Spijkerman, J M; Biessels, G J; Hendrikse, J; Petersen, E T

    2016-05-01

    To assess whether volumetric cerebrospinal fluid (CSF) MRI can be used as a surrogate for brain atrophy assessment and to evaluate how the T2 of the CSF relates to brain atrophy. Twenty-eight subjects [mean age 64 (sd 2) years] were included; T1-weighted and CSF MRI were performed. The first echo data of the CSF MRI sequence was used to obtain intracranial volume, CSF partial volume was measured voxel-wise to obtain CSF volume (VCSF) and the T2 of CSF (T2,CSF) was calculated. The correlation between VCSF/T2,CSF and brain atrophy scores [global cortical atrophy (GCA) and medial temporal lobe atrophy (MTA)] was evaluated. Relative total, peripheral subarachnoidal, and ventricular VCSF increased significantly with increased scores on the GCA and MTA (R = 0.83, 0.78 and 0.78 and R = 0.72, 0.62 and 0.86). Total, peripheral subarachnoidal, and ventricular T2 of the CSF increased significantly with higher scores on the GCA and MTA (R = 0.72, 0.70 and 0.49 and R = 0.60, 0.57 and 0.41). A fast, fully automated CSF MRI volumetric sequence is an alternative for qualitative atrophy scales. The T2 of the CSF is related to brain atrophy and could thus be a marker of neurodegenerative disease. • A 1:11 min CSF MRI volumetric sequence can evaluate brain atrophy. • CSF MRI provides accurate atrophy assessment without partial volume effects. • CSF MRI data can be processed quickly without user interaction. • The measured T 2 of the CSF is related to brain atrophy.

  6. Parallel implementation of 3D FFT with volumetric decomposition schemes for efficient molecular dynamics simulations

    Science.gov (United States)

    Jung, Jaewoon; Kobayashi, Chigusa; Imamura, Toshiyuki; Sugita, Yuji

    2016-03-01

    Three-dimensional Fast Fourier Transform (3D FFT) plays an important role in a wide variety of computer simulations and data analyses, including molecular dynamics (MD) simulations. In this study, we develop hybrid (MPI+OpenMP) parallelization schemes of 3D FFT based on two new volumetric decompositions, mainly for the particle mesh Ewald (PME) calculation in MD simulations. In one scheme, (1d_Alltoall), five all-to-all communications in one dimension are carried out, and in the other, (2d_Alltoall), one two-dimensional all-to-all communication is combined with two all-to-all communications in one dimension. 2d_Alltoall is similar to the conventional volumetric decomposition scheme. We performed benchmark tests of 3D FFT for the systems with different grid sizes using a large number of processors on the K computer in RIKEN AICS. The two schemes show comparable performances, and are better than existing 3D FFTs. The performances of 1d_Alltoall and 2d_Alltoall depend on the supercomputer network system and number of processors in each dimension. There is enough leeway for users to optimize performance for their conditions. In the PME method, short-range real-space interactions as well as long-range reciprocal-space interactions are calculated. Our volumetric decomposition schemes are particularly useful when used in conjunction with the recently developed midpoint cell method for short-range interactions, due to the same decompositions of real and reciprocal spaces. The 1d_Alltoall scheme of 3D FFT takes 4.7 ms to simulate one MD cycle for a virus system containing more than 1 million atoms using 32,768 cores on the K computer.

  7. Correlation dependence of the volumetric thermal expansion coefficient of metallic aluminum on its heat capacity

    Science.gov (United States)

    Bodryakov, V. Yu.; Bykov, A. A.

    2016-05-01

    The correlation between the volumetric thermal expansion coefficient β( T) and the heat capacity C( T) of aluminum is considered in detail. It is shown that a clear correlation is observed in a significantly wider temperature range, up to the melting temperature of the metal, along with the low-temperature range where it is linear. The significant deviation of dependence β( C) from the low-temperature linear behavior is observed up to the point where the heat capacity achieves the classical Dulong-Petit limit of 3 R ( R is the universal gas constant).

  8. Structuring feature space: a non-parametric method for volumetric transfer function generation.

    Science.gov (United States)

    Maciejewski, Ross; Woo, Insoo; Chen, Wei; Ebert, David S

    2009-01-01

    The use of multi-dimensional transfer functions for direct volume rendering has been shown to be an effective means of extracting materials and their boundaries for both scalar and multivariate data. The most common multi-dimensional transfer function consists of a two-dimensional (2D) histogram with axes representing a subset of the feature space (e.g., value vs. value gradient magnitude), with each entry in the 2D histogram being the number of voxels at a given feature space pair. Users then assign color and opacity to the voxel distributions within the given feature space through the use of interactive widgets (e.g., box, circular, triangular selection). Unfortunately, such tools lead users through a trial-and-error approach as they assess which data values within the feature space map to a given area of interest within the volumetric space. In this work, we propose the addition of non-parametric clustering within the transfer function feature space in order to extract patterns and guide transfer function generation. We apply a non-parametric kernel density estimation to group voxels of similar features within the 2D histogram. These groups are then binned and colored based on their estimated density, and the user may interactively grow and shrink the binned regions to explore feature boundaries and extract regions of interest. We also extend this scheme to temporal volumetric data in which time steps of 2D histograms are composited into a histogram volume. A three-dimensional (3D) density estimation is then applied, and users can explore regions within the feature space across time without adjusting the transfer function at each time step. Our work enables users to effectively explore the structures found within a feature space of the volume and provide a context in which the user can understand how these structures relate to their volumetric data. We provide tools for enhanced exploration and manipulation of the transfer function, and we show that the initial

  9. Accuracy of electrocardiographic-gated versus nongated volumetric intravascular ultrasound measurements of coronary arterial narrowing

    DEFF Research Database (Denmark)

    Jensen, Lisette Okkels; Thayssen, Per

    2007-01-01

    Intravascular ultrasound (IVUS) allows precise measurements of plaque plus media (P+M) volume and neointimal hyperplasia after coronary artery stenting. Conventional IVUS volumetric analysis is performed mostly without electrocardiographically gated acquisition, and the IVUS images are selected...... in changes between 2 electrocardiographically gated and 2 nongated pullbacks (lumen: 0.37 +/- 1.76 vs -0.23 +/- 2.32 mm(3), p = NS; EEM: 0.25 +/- 3.22 vs -0.94 +/- 4.27 mm(3), p = NS; P+M: -0.18 +/- 3.42 vs -0.74 +/- 3.88 mm(3), p = NS). In conclusion, in moderate atherosclerotic or stented coronary arteries...

  10. Constrained reverse diffusion for thick slice interpolation of 3D volumetric MRI images.

    Science.gov (United States)

    Neubert, Aleš; Salvado, Olivier; Acosta, Oscar; Bourgeat, Pierrick; Fripp, Jurgen

    2012-03-01

    Due to physical limitations inherent in magnetic resonance imaging scanners, three dimensional volumetric scans are often acquired with anisotropic voxel resolution. We investigate several interpolation approaches to reduce the anisotropy and present a novel approach - constrained reverse diffusion for thick slice interpolation. This technique was compared to common methods: linear and cubic B-Spline interpolation and a technique based on non-rigid registration of neighboring slices. The methods were evaluated on artificial MR phantoms and real MR scans of human brain. The constrained reverse diffusion approach delivered promising results and provides an alternative for thick slice interpolation, especially for higher anisotropy factors.

  11. Mass-conserved volumetric lattice Boltzmann method for complex flows with willfully moving boundaries.

    Science.gov (United States)

    Yu, Huidan; Chen, Xi; Wang, Zhiqiang; Deep, Debanjan; Lima, Everton; Zhao, Ye; Teague, Shawn D

    2014-06-01

    In this paper, we develop a mass-conserved volumetric lattice Boltzmann method (MCVLBM) for numerically solving fluid dynamics with willfully moving arbitrary boundaries. In MCVLBM, fluid particles are uniformly distributed in lattice cells and the lattice Boltzmann equations deal with the time evolution of the particle distribution function. By introducing a volumetric parameter P(x,y,z,t) defined as the occupation of solid volume in the cell, we distinguish three types of lattice cells in the simulation domain: solid cell (pure solid occupation, P=1), fluid cell (pure fluid occupation, P=0), and boundary cell (partial solid and partial fluid, 0Boltzmann equations are self-regularized through P and consist of three parts: (1) collision taking into account the momentum exchange between the willfully moving boundary and the flow; (2) streaming accompanying a volumetric bounce-back procedure in boundary cells; and (3) boundary-induced volumetric fluid migration moving the residual fluid particles into the flow domain when the boundary swipes over a boundary cell toward a solid cell. The MCVLBM strictly satisfies mass conservation and can handle irregular boundary orientation and motion with respect to the mesh. Validation studies are carried out in four cases. The first is to simulate fluid dynamics in syringes focusing on how MCVLBM captures the underlying physics of flow driven by a willfully moving piston. The second and third cases are two-dimensional (2D) peristaltic flow and three-dimensional (3D) pipe flow, respectively. In each case, we compare the MCVLBM simulation result with the analytical solution and achieve quantitatively good agreements. The fourth case is to simulate blood flow in human aortic arteries with a very complicated irregular boundary. We study steady flow in two dimensions and unsteady flow via the pulsation of the cardiac cycle in three dimensions. In the 2D case, both vector (velocity) and scalar (pressure) fields are compared to

  12. Cellular resolution volumetric in vivo retinal imaging with adaptive optics–optical coherence tomography◊

    Science.gov (United States)

    Zawadzki, Robert J.; Choi, Stacey S.; Fuller, Alfred R.; Evans, Julia W.; Hamann, Bernd; Werner, John S.

    2009-01-01

    Ultrahigh-resolution adaptive optics–optical coherence tomography (UHR-AO-OCT) instrumentation allowing monochromatic and chromatic aberration correction was used for volumetric in vivo retinal imaging of various retinal structures including the macula and optic nerve head (ONH). Novel visualization methods that simplify AO-OCT data viewing are presented, and include co-registration of AO-OCT volumes with fundus photography and stitching of multiple AO-OCT sub-volumes to create a large field of view (FOV) high-resolution volume. Additionally, we explored the utility of Interactive Science Publishing by linking all presented AO-OCT datasets with the OSA ISP software. PMID:19259248

  13. Cellular resolution volumetric in vivo retinal imaging with adaptive optics-optical coherence tomography.

    Science.gov (United States)

    Zawadzki, Robert J; Choi, Stacey S; Fuller, Alfred R; Evans, Julia W; Hamann, Bernd; Werner, John S

    2009-03-02

    Ultrahigh-resolution adaptive optics-optical coherence tomography (UHR-AO-OCT) instrumentation allowing monochromatic and chromatic aberration correction was used for volumetric in vivo retinal imaging of various retinal structures including the macula and optic nerve head (ONH). Novel visualization methods that simplify AO-OCT data viewing are presented, and include co-registration of AO-OCT volumes with fundus photography and stitching of multiple AO-OCT sub-volumes to create a large field of view (FOV) high-resolution volume. Additionally, we explored the utility of Interactive Science Publishing by linking all presented AO-OCT datasets with the OSA ISP software.

  14. Volumetric and Transport Properties of Aqueous NaB(OH)4 Solutions

    Institute of Scientific and Technical Information of China (English)

    周永全; 房春晖; 房艳; 朱发岩

    2013-01-01

    Density, pH, viscosity, conductivity and the Raman spectra of aqueous NaB(OH)4 solutions precisely measured as functions of concentration at different temperatures (293.15, 298.15, 303.15, 313.15 and 323.15 K) are presented. Polyborate distributions in aqueous NaB(OH)4 solution were calculated, covering all the concentration range, 4B(OH)− is the most dominant species, other polyborate anions are less than 5.0%. The volumetric and the transport properties were discussed in detail, both of these properties indicate that 4B(OH)− behaves as a struc-ture-disordered anion.

  15. Design and Range of Application of Slot Bushings with Volumetric Orifice Fields

    Institute of Scientific and Technical Information of China (English)

    ULYBYSHEV V. V.; VASEKIN V. V.; PERELMAN S. L.

    2012-01-01

    A design of a slot bushing with a volumetric field has been developed,which allows to produce continuous fibers from melts with difficult processing characteristics in order to produce fibers with better operating characteristics.The operability of the design was confirrned when solving two problems of special technological complexity.1.400- and 800-orifice bushings for production of continuous fibers from the basalt melt have been developed and recommended for manufacture.2.The process of production of continuous fibers from standard glass using 2400-orifice bushing with perforated plates instead of orifice tips without air cooling,has been realized for the first time.

  16. Techniques to measure volumetric flow and particulate concentration in stacks with cyclonic flow

    Science.gov (United States)

    Sterrett, J. D.; Barbin, A. R.; Reece, J. W.; Carter, W. G.; Ferguson, B. B.

    1982-08-01

    It was determined that an in stack venturi can accurately measure volumetric flow in stacks with a severe cyclonic flow profile. The design requirements of the venturi are described. Also described was a low head loss, egg crate shaped device that effectively straightens cyclonic flow. Installation of such a device after a tangential inlet to a tall stack can result in considerable energy savings because it takes less fan power to push the straightened flow. Results to determine the particulate distribution downstream of the egg crate were inconclusive.

  17. Sensitivity of collapsed arc QA method for delivery errors in Volumetric Modulated Arc Therapy (VMAT)

    Science.gov (United States)

    Young, Tony; Xing, Aitang; Vial, Philp; Thwaites, David; Holloway, Lois; Arumugam, Sankar

    2015-01-01

    In this paper the sensitivity of an Electronic Portal Imaging Device (EPID) to detecting introduced Volumetric Arc Therapy (VMAT) treatment errors was studied using the Collapsed Arc method. Two clinical Head and Neck (H&N) and Prostate treatment plans had gantry dependent dose and MLC errors introduced to the plans. These plans were then delivered to an Elekta Synergy Linear Accelerator EPID and compared to the original treatment planning system Collapsed Arc dose matrix. With the Collapsed Arc technique the EPID was able to detect MLC errors down to 2mm and dose errors of down to 3% depending on the treatment plan complexity and gamma tolerance used.

  18. Real-time volumetric visualization of high-resolution array and toroidal volume search sonar data

    Science.gov (United States)

    Cross, Robert A.

    1998-09-01

    The Advanced Volume Visualization Display (AVVD) research program is a joint research program between the Fraunhofer Center for Research in Computer Graphics, Inc. and Innovative Research and Development Corp. It is dedicated the application of the human visual system to real-time visualization of high- resolution volumetric sensor data sets. The AVVD program has successfully demonstrated its application to undersea imaging using data from the Naval Undersea Warfare Center -- Division Newport's High Resolution Array (HRA), and from the Naval Surface Warfare Center -- Coastal System Stations's Toroidal Volume Search Sonar (TVSS).

  19. An Universal Modeling Method for Enhancing the Volumetric Accuracy of CNC Machine Tools

    Institute of Scientific and Technical Information of China (English)

    2002-01-01

    Volumetric error modeling method is an important te ch nique for enhancement the accuracy of CNC machine tools by error compensation. I n the research field, the main question is how to find an universal kinematics m odeling method for different kinds of NC machine tools. Multi-body system theor y is always used to solve the dynamics problem of complex physical system. But t ill now, the error factors that always exist in practice system is still not con sidered. In this paper, the accuracy kinematics of MB...

  20. Reconstruction of volumetric ultrasound panorama based on improved 3D SIFT.

    Science.gov (United States)

    Ni, Dong; Chui, Yim Pan; Qu, Yingge; Yang, Xuan; Qin, Jing; Wong, Tien-Tsin; Ho, Simon S H; Heng, Pheng Ann

    2009-10-01

    Registration of ultrasound volumes is a key issue for the reconstruction of volumetric ultrasound panorama. In this paper, we propose an improved three-dimensional (3D) scale invariant feature transform (SIFT) algorithm to globally register ultrasound volumes acquired from dedicated ultrasound probe, where local deformations are corrected by block-based warping algorithm. Original SIFT algorithm is extended to 3D and improved by combining the SIFT detector with Rohr3D detector to extract complementary features and applying the diffusion distance algorithm for robust feature comparison. Extensive experiments have been performed on both phantom and clinical data sets to demonstrate the effectiveness and robustness of our approach.

  1. Direct volumetric rendering based on point primitives in OpenGL.

    Science.gov (United States)

    da Rosa, André Luiz Miranda; de Almeida Souza, Ilana; Yuuji Hira, Adilson; Zuffo, Marcelo Knörich

    2006-01-01

    The aim of this project is to present a renderization by software algorithm of acquired volumetric data. The algorithm was implemented in Java language and the LWJGL graphical library was used, allowing the volume renderization by software and thus preventing the necessity to acquire specific graphical boards for the 3D reconstruction. The considered algorithm creates a model in OpenGL, through point primitives, where each voxel becomes a point with the color values related to this pixel position in the corresponding images.

  2. High light extraction efficiency in bulk-GaN based volumetric violet light-emitting diodes

    Energy Technology Data Exchange (ETDEWEB)

    David, Aurelien, E-mail: adavid@soraa.com; Hurni, Christophe A.; Aldaz, Rafael I.; Cich, Michael J.; Ellis, Bryan; Huang, Kevin; Steranka, Frank M.; Krames, Michael R. [Soraa Inc., 6500 Kaiser Dr., Fremont, California 94555 (United States)

    2014-12-08

    We report on the light extraction efficiency of III-Nitride violet light-emitting diodes with a volumetric flip-chip architecture. We introduce an accurate optical model to account for light extraction. We fabricate a series of devices with varying optical configurations and fit their measured performance with our model. We show the importance of second-order optical effects like photon recycling and residual surface roughness to account for data. We conclude that our devices reach an extraction efficiency of 89%.

  3. The frontal and temporal horn ratio to assess dimension of paediatric hydrocephalus: a comparative volumetric study.

    Science.gov (United States)

    Antes, Sebastian; Welsch, Melanie; Kiefer, Michael; Gläser, Mareike; Körner, Heiko; Eymann, Regina

    2013-01-01

    Magnetic resonance imaging and cranial -ultrasound are the most frequently implemented imaging methods for investigating the infantile hydrocephalic brain. A general and reliable measurement index that can be equally applied in both imaging methods to assess dimension of ventricular dilatation is currently not available. For this purpose, a new parameter called the frontal and temporal horn ratio - determinable in coronal slices of the brain - was developed and evaluated in a comparative volumetric retrospective study: Statistical analyses of 118 MRIs of 46 different shunt-treated pediatric patients revealed a good linear correlation between the new index and the actual ventricular volume.

  4. Enhancing Volumetric Bouligand-Minkowski Fractal Descriptors by using Functional Data Analysis

    CERN Document Server

    Florindo, João Batista; Bruno, Odemir Martinez; 10.1142/S0129183111016701

    2012-01-01

    This work proposes and study the concept of Functional Data Analysis transform, applying it to the performance improving of volumetric Bouligand-Minkowski fractal descriptors. The proposed transform consists essentially in changing the descriptors originally defined in the space of the calculus of fractal dimension into the space of coefficients used in the functional data representation of these descriptors. The transformed decriptors are used here in texture classification problems. The enhancement provided by the FDA transform is measured by comparing the transformed to the original descriptors in terms of the correctness rate in the classification of well known datasets.

  5. 3D Volumetric Modeling and Microvascular Reconstruction of Irradiated Lumbosacral Defects After Oncologic Resection

    Directory of Open Access Journals (Sweden)

    Emilio Garcia-Tutor

    2016-12-01

    Full Text Available Background: Locoregional flaps are sufficient in most sacral reconstructions. However, large sacral defects due to malignancy necessitate a different reconstructive approach, with local flaps compromised by radiation and regional flaps inadequate for broad surface areas or substantial volume obliteration. In this report, we present our experience using free muscle transfer for volumetric reconstruction in such cases, and demonstrate 3D haptic models of the sacral defect to aid preoperative planning.Methods: Five consecutive patients with irradiated sacral defects secondary to oncologic resections were included, surface area ranging from 143-600cm2. Latissimus dorsi-based free flap sacral reconstruction was performed in each case, between 2005 and 2011. Where the superior gluteal artery was compromised, the subcostal artery was used as a recipient vessel. Microvascular technique, complications and outcomes are reported. The use of volumetric analysis and 3D printing is also demonstrated, with imaging data converted to 3D images suitable for 3D printing with Osirix software (Pixmeo, Geneva, Switzerland. An office-based, desktop 3D printer was used to print 3D models of sacral defects, used to demonstrate surface area and contour and produce a volumetric print of the dead space needed for flap obliteration. Results: The clinical series of latissimus dorsi free flap reconstructions is presented, with successful transfer in all cases, and adequate soft-tissue cover and volume obliteration achieved. The original use of the subcostal artery as a recipient vessel was successfully achieved. All wounds healed uneventfully. 3D printing is also demonstrated as a useful tool for 3D evaluation of volume and dead-space.Conclusion: Free flaps offer unique benefits in sacral reconstruction where local tissue is compromised by irradiation and tumor recurrence, and dead-space requires accurate volumetric reconstruction. We describe for the first time the use of

  6. Finite element analysis of volumetrically heated fluids in an axisymmetric enclosure

    Energy Technology Data Exchange (ETDEWEB)

    Gartling, D.K.

    1979-01-01

    A general purpose finite element computer code has been used to analyze the steady state and transient response of a confined fluid that is heated volumetrically. The numerical procedure is demonstrated to be capable of resolving flow fields of considerable complexity without undue computational expense. Results are discussed for a Grashof number range (4.0 x 10/sup 4/ to 4.0 x 10/sup 6/) in which the flow varies from a steady, single cell configuration to a multiple cell configuration that includes a periodic interaction.

  7. Preliminary performance analysis of a transverse flow spectrally selective two-slab packed bed volumetric receiver

    CSIR Research Space (South Africa)

    Roos, TH

    2016-05-01

    Full Text Available stream_source_info Roos_2016_ABSTRACT.pdf.txt stream_content_type text/plain stream_size 2694 Content-Encoding UTF-8 stream_name Roos_2016_ABSTRACT.pdf.txt Content-Type text/plain; charset=UTF-8 21st SolarPACES... International Conference (SolarPACES 2015), 13-16 October 2015 Preliminary Performance Analysis of a Transverse Flow Spectrally Selective Two-slab Packed Bed Volumetric Receiver Thomas H. Roos1, a) and Thomas M. Harms2, b) 1Aeronautical Systems...

  8. Two-dimensional catheter arrays for real-time intracardiac volumetric imaging

    Science.gov (United States)

    Light, Edward D.; Fiering, Jason O.; Lee, Warren; Wolf, Patrick D.; Smith, Stephen W.

    1999-06-01

    We have previously described 2D arrays of several thousand elements operating up to 5.0 MHz for transthoracic cardiac imaging. Lately, there has been interest in developing catheter based intracardiac imaging systems to aid in the precise tracking of anatomical features for improved diagnoses and therapies. We have constructed several arrays for real time intracardiac volumetric imaging based upon two different designs; a 10 X 10 equals 100 element 5.0 MHz forward looking 2D array, and a 13 X 11 equals 143 element 5.0 MHz 2D array for side scanning applications.

  9. Densely-packed graphene/conducting polymer nanoparticle papers for high-volumetric-performance flexible all-solid-state supercapacitors

    Science.gov (United States)

    Yang, Chao; Zhang, Liling; Hu, Nantao; Yang, Zhi; Wei, Hao; Xu, Zhichuan J.; Wang, Yanyan; Zhang, Yafei

    2016-08-01

    Graphene-based all-solid-state supercapacitors (ASSSCs) are one of the most ideal candidates for high-performance flexible power sources. The achievement of high volumetric energy density is highly desired for practical application of this type of ASSSCs. Here, we present a facile method to boost volumetric performances of graphene-based flexible ASSSCs through incorporation of ultrafine polyaniline-poly(4-styrenesulfonate) (PANI-PSS) nanoparticles in reduced graphene oxide (rGO) papers. A compact structure is obtained via intimate contact and π-π interaction between PANI-PSS nanoparticles and rGO sheets. The hybrid paper electrode with the film thickness of 13.5 μm, shows an extremely high volumetric specific capacitance of 272 F/cm3 (0.37 A/cm3 in a three-electrode cell). The assembled ASSSCs show a large volumetric specific capacitance of 217 F/cm3 (0.37 A/cm3 in a two-electrode cell), high volumetric energy and power density, excellent capacitance stability, small leakage current as well as low self-discharge characteristics, revealing the usefulness of this robust hybrid paper for high-performance flexible energy storage devices.

  10. 鲑鱼降钙素联合钙尔奇D对老年髋部骨折患者腰椎骨密度的影响%Effect of Salmon Calcitonin combined Caltrate on lumbar vertebra BMD of elder patients with hip fracture

    Institute of Scientific and Technical Information of China (English)

    平少华; 梁春雨; 朱艳丽; 白月民; 屠世韵; 胡娜; 常婷婷

    2012-01-01

    目的 观察鲑鱼降钙素联合钙尔奇D对改善老年髋部骨折后卧床患者腰椎骨密度的临床疗效.方法 将30例患肢行胫骨结节骨牵引术的老年髋部骨折患者随机分为两组,治疗组15例,采用鲑鱼降钙素联合钙尔奇D进行治疗8周.对照组15例,未接受治疗.对比观察两组治疗前后腰椎骨密度(BMD)的变化情况.结果 对照组患者腰椎BMD较治疗前减低,差异有统计学意义(P 0.05).结论 鲑鱼降钙素联合钙尔奇D可以预防老年髋部骨折后卧床患者的腰椎骨质流失,预防废用性骨质疏松.%Objective To assess the effects of Salmon Calcitonin combined Caltrate on BMD of lumbar vertebra in elder patients with hip fracture. Methods 30 elder patients in bed with hip fracture were divided into two groups. Patients in treatment group were treated by Salmon Calcitonin combined Caltrate for 8 weeks while patients in control group weren't. BMD of lumbar vertebra was measured after 8 weeks. Results BMD of lumbar vertebra was found to reduce in the control group after treatment (P 0.05). Conclusion Salmon Calcitonin combined Caltrate is effective in preventing BMD of lumbar vertebra from reducing in elder patients with hip fracture.

  11. Correlation between femoral head iron content and BMD in postmenopausal women%绝经后女性股骨头铁含量与骨密度的相关性

    Institute of Scientific and Technical Information of China (English)

    王兵; 赵环; 姜习凤; 艾红珍; 钱志远; 张林林; 董启榕; 徐又佳

    2013-01-01

    contents of femoral neck fracture patients (postm-enopausal women) , and further contacting of bone mineral density ( BMD) , serum ferritin ( FER) and serum bone metabolic markers to explore the potential values of the iron contents of bone tissue in osteoporosis patients. Methods 10 elderly women aged 56 ~ 87 years old (an average of 72. 6 years old) as the older age group with the brittle femoral neck fracture ( 6 cases with walking falls, while 4 cases with sprains fell) ; Meanwhile 6 cases of young female violence femoral neck fracture (traffic accidents in 4 cases, rider fell 1 cases, falls 1 case) as the control group aged 19~43 years with mean 31 years; Both cases were hospitalized, single, non-open fracture with no inflammation abnormal indicators and no previous pathological history of iron overload. The serum specimens were measured for iron metabolism and bone metabolic markers were detected, the biopsy specimens were performed in both groups by a special require to detect the bone iron contents and bone iron were stained after operation and BMD considered of lumbar vertebras and hips were undertook after surgeries. Results Hip and L1-L4 BMD values, FER and 25-OH-VD, of elderly women were outside the reference range; while the control group were within it. The bone iron contents, FER, β-CTX and TRAP5b of postmenopausal group were significantly higher than those of the control group (88.9 ±47.2 μg/g vs 32.5 ± 12.7 μg/g, 234.3 ± 91. 70 ng/Ml vs 69. 6 ± 42. 5 ng/Ml, 643. 4 ± 284. 3 pg/Ml vs 254. 3 ± 129. 9 pg/Ml, 3. 4 ±0. 73 U/L vs 2. 3 ± 0. 45 U/L; P <0. 05) , while hip and L1-4 BMD values were less than the control group (0. 63 ±0. 11 g/cm2 vs 0. 88 ± 0. 67 g/cm , 0. 87 ± 0. 10 g/cm vs 1. 06 ± 0. 18 g/cm ; P < 0. 05 ) . HE staining covered by Prussian showed iron was seen as blue-staining lines at the bone trabecular structures in old age group, and no obvious blue staining structures of control group were appeared; Specific iron deposition (blue

  12. The Hubble Space Telescope Cluster Supernova Survey: VI. The Volumetric Type Ia Supernova Rate

    CERN Document Server

    Barbary, K; Amanullah, R; Brodwin, M; Connolly, N; Dawson, K S; Doi, M; Eisenhardt, P; Faccioli, L; Fadeyev, V; Fakhouri, H K; Fruchter, A S; Gilbank, D G; Gladders, M D; Goldhaber, G; Goobar, A; Hattori, T; Hsiao, E; Huang, X; Ihara, Y; Kashikawa, N; Koester, B; Konishi, K; Kowalski, M; Lidman, C; Lubin, L; Meyers, J; Morokuma, T; Oda, T; Panagia, N; Perlmutter, S; Postman, M; Ripoche, P; Rosati, P; Rubin, D; Schlegel, D J; Spadafora, A L; Stanford, S A; Strovink, M; Suzuki, N; Takanashi, N; Tokita, K; Yasuda, N

    2011-01-01

    We present a measurement of the volumetric Type Ia supernova (SN Ia) rate out to z ~ 1.6 from the Hubble Space Telescope Cluster Supernova Survey. In observations spanning 189 orbits with the Advanced Camera for Surveys we discovered 29 SNe, of which approximately 20 are SNe Ia. Twelve of these SNe Ia are located in the foregrounds and backgrounds of the clusters targeted in the survey. Using these new data, we derive the volumetric SN Ia rate in four broad redshift bins, finding results consistent with previous measurements at z > 1 and strengthening the case for a SN Ia rate that is equal to or greater than ~0.6 x 10^-4/yr/Mpc^3 at z ~ 1 and flattening out at higher redshift. We provide SN candidates and efficiency calculations in a form that makes it easy to rebin and combine these results with other measurements for increased statistics. Finally, we compare the assumptions about host-galaxy dust extinction used in different high-redshift rate measurements, finding that different assumptions may induce sig...

  13. Theory of Volumetric Moving Dislocation in Poroelastic Halfspace and Characterization of Magma Intrusion Events

    Institute of Scientific and Technical Information of China (English)

    Ouyang Zhihua; Elsworth Derek; Sheng Jianlong

    2005-01-01

    The undrained change in pore fluid pressure that accompanies dike intrusion may be conveniently represented as a moving volumetric dislocation. The concept of a dilation center was developed to represent the field of undrained pressure change in a saturated linear elastic medium. Since instantaneous pore fluid pressures can be developed to a considerable distance from the dislocation, monitoring the rate of pressure generation and subsequent pressure dissipation in a fully coupled manner enables certain characteristics of the resulting dislocation to be defined. The principal focus of this study is the application of dislocation-based methods to analyze the behavior of the fluid pressure response induced by intrusive dislocations in a semi-infinite space, such as dike intrusion, hydraulic fracturing and piezometer insertion. Partially drained pore pressures result from the isothermal introduction of volumetric moving pencil-like dislocations described as analogs to moving point dislocation within a semi-infinite saturated elastic medium. To represent behavior within the halfspace, an image dislocation is positioned under the moving coordinate frame fixed to the front of the primary moving dislocation, to yield an approximate solution for pore pressure for constant fluid pressure conditions. Induced pore pressures are concisely described under a minimum set of dimensionless parameter groupings representing propagation velocity, and relative geometry. Charts defining induced pore fluid pressure at a static measuring point provide a meaningful tool for determining unknown parameters in data reduction. Two intrusive events at Krafla, Iceland are examined using the type curve matching techniques. Predicted parameters agree favorably with field data.

  14. Optimal spacing within a tubed, volumetric, cavity receiver suitable for modular molten salt solar towers

    Science.gov (United States)

    Turner, Peter

    2016-05-01

    A 2-dimensional radiation analysis has been developed to analyse the radiative efficiency of an arrangement of heat transfer tubes distributed in layers but spaced apart to form a tubed, volumetric receiver. Such an arrangement could be suitable for incorporation into a cavity receiver. Much of the benefit of this volumetric approach is gained after using 5 layers although improvements do continue with further layers. The radiation analysis splits each tube into multiple segments in which each segment surface can absorb, reflect and radiate rays depending on its surface temperature. An iterative technique is used to calculate appropriate temperatures depending on the distribution of the net energy absorbed and assuming that the cool heat transfer fluid (molten salt) starts at the front layer and flows back through successive layers to the rear of the cavity. Modelling the finite diameter of each layer of tubes increases the ability of a layer to block radiation scattered at acute angles and this effect is shown to reduce radiation losses by nearly 25% compared to the earlier 1-d analysis. Optimum efficient designs tend to occur when the blockage factor is 0.2 plus the inverse of the number of tube layers. It is beneficial if the distance between successive layers is ≥ 2 times the diameter of individual tubes and in this situation, if the incoming radiation is spread over a range of angles, the performance is insensitive to the degree of any tube positional offset or stagger between layers.

  15. Volumetrics of CO{sub 2} Storage in Deep Saline Formations

    Energy Technology Data Exchange (ETDEWEB)

    Steele-MacInnis, Matthew; Capobianco, Ryan M; Dilmore, Robert; Goodman, Angela; Guthrie, George; Rimstidt, J Donald; Bodnar, Robert J

    2013-01-01

    Concern about the role of greenhouse gases in global climate change has generated interest in sequestering CO{sub 2} from fossil-fuel combustion in deep saline formations. Pore space in these formations is initially filled with brine, and space to accommodate injected CO{sub 2} must be generated by displacing brine, and to a lesser extent by compression of brine and rock. The formation volume required to store a given mass of CO{sub 2} depends on the storage mechanism. We compare the equilibrium volumetric requirements of three end-member processes: CO{sub 2} stored as a supercritical fluid (structural or stratigraphic trapping); CO{sub 2} dissolved in pre-existing brine (solubility trapping); and CO{sub 2} solubility enhanced by dissolution of calcite. For typical storage conditions, storing CO{sub 2} by solubility trapping reduces the volume required to store the same amount of CO{sub 2} by structural or stratigraphic trapping by about 50%. Accessibility of CO{sub 2} to brine determines which storage mechanism (structural/stratigraphic versus solubility) dominates at a given time, which is a critical factor in evaluating CO{sub 2} volumetric requirements and long-term storage security.

  16. Early clinical experience with volumetric modulated arc therapy in head and neck cancer patients

    Directory of Open Access Journals (Sweden)

    Cozzi Luca

    2010-10-01

    Full Text Available Abstract Background To report about early clinical experience in radiation treatment of head and neck cancer of different sites and histology by volumetric modulated arcs with the RapidArc technology. Methods During 2009, 45 patients were treated at Istituto Clinico Humanitas with RapidArc (28 males and 17 females, median age 65 years. Of these, 78% received concomitant chemotherapy. Thirty-six patients were treated as exclusive curative intent (group A, three as postoperative curative intent (group B and six with sinonasal tumours (group C. Dose prescription was at Planning Target Volumes (PTV with simultaneous integrated boost: 54.45Gy and 69.96Gy in 33 fractions (group A; 54.45Gy and 66Gy in 33 fractions (group B and 55Gy in 25 fractions (group C. Results Concerning planning optimization strategies and constraints, as per PTV coverage, for all groups, D98% > 95% and V95% > 99%. As regards organs at risk, all planning objectives were respected, and this was correlated with observed acute toxicity rates. Only 28% of patients experienced G3 mucositis, 14% G3 dermitis 44% had G2 dysphagia. Nobody required feeding tubes to be placed during treatment. Acute toxicity is also related to chemotherapy. Two patients interrupted the course of radiotherapy because of a quick worsening of general clinical condition. Conclusions These preliminary results stated that volumetric modulated arc therapy in locally advanced head and neck cancers is feasible and effective, with acceptable toxicities.

  17. Volumetric synthetic aperture imaging with a piezoelectric 2D row-column probe

    Science.gov (United States)

    Bouzari, Hamed; Engholm, Mathias; Christiansen, Thomas Lehrmann; Beers, Christopher; Lei, Anders; Stuart, Matthias Bo; Nikolov, Svetoslav Ivanov; Thomsen, Erik Vilain; Jensen, Jørgen Arendt

    2016-04-01

    The synthetic aperture (SA) technique can be used for achieving real-time volumetric ultrasound imaging using 2-D row-column addressed transducers. This paper investigates SA volumetric imaging performance of an in-house prototyped 3 MHz λ/2-pitch 62+62 element piezoelectric 2-D row-column addressed transducer array. Utilizing single element transmit events, a volume rate of 90 Hz down to 14 cm deep is achieved. Data are obtained using the experimental ultrasound scanner SARUS with a 70 MHz sampling frequency and beamformed using a delay-and-sum (DAS) approach. A signal-to-noise ratio of up to 32 dB is measured on the beamformed images of a tissue mimicking phantom with attenuation of 0.5 dB cm-1 MHz-1, from the surface of the probe to the penetration depth of 300λ. Measured lateral resolution as Full-Width-at-Half-Maximum (FWHM) is between 4λ and 10λ for 18% to 65% of the penetration depth from the surface of the probe. The averaged contrast is 13 dB for the same range. The imaging performance assessment results may represent a reference guide for possible applications of such an array in different medical fields.

  18. Mammographic density measurement: a comparison of automated volumetric density measurement to BIRADS

    Science.gov (United States)

    McEntee, Mark F.; Damases, Christine N.

    2014-03-01

    The aim of this study is to compare mammographic breast density assessment with automated volumetric software with Breast Imaging Reporting and Data System (BIRADS) categorization by radiologists on two imaging systems. A data set of 120 mammograms was classified by twenty American Board of Radiology (ABR) Examiners. The mammograms were of 20 women (mean age, 60 years; range, 42-89 years). These women were image twice once with GE system and the following year with Hologic system. These images also had their volumetric density classified by using Volpara Density Grade (VDG). The radiologists were asked to estimate the mammographic density according to BIRADS categories (1- 4). There was a moderate agreement between VDG classification and radiologist BIRADS density shown with Cohen's Kappa (K=0.45; pBIRADS having a mean of 2.13 and the mean VDG higher at 2.50 (t = -11.99; pBIRADS showed a positive strong correlation (r=0.84; pBIRADS and VDG AvBD% also showed a strong positive correlation (r=0.86; pBIRADS categories for each of the VDG AvBD% classifications. Using Volpara, the Hologic system showed a higher meanAvBD% (10.02 vs. 9.97). However using BIRADS the Hologic systems showed a lower mean (2.05 vs. 2.21). Automated systems demonstrated higher internal validity. The results demonstrated a moderate agreement and a strong correlation between VDG classification and radiologist BIRADS density assessment.

  19. Impact of Turbocharger Non-Adiabatic Operation on Engine Volumetric Efficiency and Turbo Lag

    Directory of Open Access Journals (Sweden)

    S. Shaaban

    2012-01-01

    Full Text Available Turbocharger performance significantly affects the thermodynamic properties of the working fluid at engine boundaries and hence engine performance. Heat transfer takes place under all circumstances during turbocharger operation. This heat transfer affects the power produced by the turbine, the power consumed by the compressor, and the engine volumetric efficiency. Therefore, non-adiabatic turbocharger performance can restrict the engine charging process and hence engine performance. The present research work investigates the effect of turbocharger non-adiabatic performance on the engine charging process and turbo lag. Two passenger car turbochargers are experimentally and theoretically investigated. The effect of turbine casing insulation is also explored. The present investigation shows that thermal energy is transferred to the compressor under all circumstances. At high rotational speeds, thermal energy is first transferred to the compressor and latter from the compressor to the ambient. Therefore, the compressor appears to be “adiabatic” at high rotational speeds despite the complex heat transfer processes inside the compressor. A tangible effect of turbocharger non-adiabatic performance on the charging process is identified at turbocharger part load operation. The turbine power is the most affected operating parameter, followed by the engine volumetric efficiency. Insulating the turbine is recommended for reducing the turbine size and the turbo lag.

  20. Numerical analysis of radiation propagation in innovative volumetric receivers based on selective laser melting techniques

    Science.gov (United States)

    Alberti, Fabrizio; Santiago, Sergio; Roccabruna, Mattia; Luque, Salvador; Gonzalez-Aguilar, Jose; Crema, Luigi; Romero, Manuel

    2016-05-01

    Volumetric absorbers constitute one of the key elements in order to achieve high thermal conversion efficiencies in concentrating solar power plants. Regardless of the working fluid or thermodynamic cycle employed, design trends towards higher absorber output temperatures are widespread, which lead to the general need of components of high solar absorptance, high conduction within the receiver material, high internal convection, low radiative and convective heat losses and high mechanical durability. In this context, the use of advanced manufacturing techniques, such as selective laser melting, has allowed for the fabrication of intricate geometries that are capable of fulfilling the previous requirements. This paper presents a parametric design and analysis of the optical performance of volumetric absorbers of variable porosity conducted by means of detailed numerical ray tracing simulations. Sections of variable macroscopic porosity along the absorber depth were constructed by the fractal growth of single-cell structures. Measures of performance analyzed include optical reflection losses from the absorber front and rear faces, penetration of radiation inside the absorber volume, and radiation absorption as a function of absorber depth. The effects of engineering design parameters such as absorber length and wall thickness, material reflectance and porosity distribution on the optical performance of absorbers are discussed, and general design guidelines are given.

  1. Multitracer: a Java-based tool for anatomic delineation of grayscale volumetric images.

    Science.gov (United States)

    Woods, Roger P

    2003-08-01

    A Java-based tool for delineating anatomic boundaries in 8- and 16- bit grayscale volumetric images is described. Modern features implemented by the tool include the ability to simultaneously view the current cursor position and the previously delineated boundaries on three orthogonal planes, the ability to magnify images during delineation using high-quality interpolation, the ability to encode and save boundaries with subvoxel resolution, and the ability to utilize coregistered images interchangeably during delineation. Additional features facilitate use of the tool in a multiuser, multiplatform environment and provide support for the documentation of anatomic delineation protocols. In addition to providing direct estimates of structure volumes, areas, and lengths, the tool allows contoured boundaries to be exported for more sophisticated analyses. The tool also provides support for manual editing of image volumes to remove confounding structures and for manual correction of image volumes that have been inaccurately edited. In addition to its research utility, the tool also has potential value in education, allowing students to interact with volumetric data and structural boundaries in three dimensions.

  2. Volumetric characterization of human patellar cartilage matrix on phase contrast x-ray computed tomography

    Science.gov (United States)

    Abidin, Anas Z.; Nagarajan, Mahesh B.; Checefsky, Walter A.; Coan, Paola; Diemoz, Paul C.; Hobbs, Susan K.; Huber, Markus B.; Wismüller, Axel

    2015-03-01

    Phase contrast X-ray computed tomography (PCI-CT) has recently emerged as a novel imaging technique that allows visualization of cartilage soft tissue, subsequent examination of chondrocyte patterns, and their correlation to osteoarthritis. Previous studies have shown that 2D texture features are effective at distinguishing between healthy and osteoarthritic regions of interest annotated in the radial zone of cartilage matrix on PCI-CT images. In this study, we further extend the texture analysis to 3D and investigate the ability of volumetric texture features at characterizing chondrocyte patterns in the cartilage matrix for purposes of classification. Here, we extracted volumetric texture features derived from Minkowski Functionals and gray-level co-occurrence matrices (GLCM) from 496 volumes of interest (VOI) annotated on PCI-CT images of human patellar cartilage specimens. The extracted features were then used in a machine-learning task involving support vector regression to classify ROIs as healthy or osteoarthritic. Classification performance was evaluated using the area under the receiver operating characteristic (ROC) curve (AUC). The best classification performance was observed with GLCM features correlation (AUC = 0.83 +/- 0.06) and homogeneity (AUC = 0.82 +/- 0.07), which significantly outperformed all Minkowski Functionals (p GLCM-derived statistical features can distinguish between healthy and osteoarthritic tissue with high accuracy.

  3. Volumetric texture analysis of breast lesions on contrast-enhanced magnetic resonance images.

    Science.gov (United States)

    Chen, Weijie; Giger, Maryellen L; Li, Hui; Bick, Ulrich; Newstead, Gillian M

    2007-09-01

    Automated image analysis aims to extract relevant information from contrast-enhanced magnetic resonance images (CE-MRI) of the breast and improve the accuracy and consistency of image interpretation. In this work, we extend the traditional 2D gray-level co-occurrence matrix (GLCM) method to investigate a volumetric texture analysis approach and apply it for the characterization of breast MR lesions. Our database of breast MR images was obtained using a T1-weighted 3D spoiled gradient echo sequence and consists of 121 biopsy-proven lesions (77 malignant and 44 benign). A fuzzy c-means clustering (FCM) based method is employed to automatically segment 3D breast lesions on CE-MR images. For each 3D lesion, a nondirectional GLCM is then computed on the first postcontrast frame by summing 13 directional GLCMs. Texture features are extracted from the nondirectional GLCMs and the performance of each texture feature in the task of distinguishing between malignant and benign breast lesions is assessed by receiver operating characteristics (ROC) analysis. Our results show that the classification performance of volumetric texture features is significantly better than that based on 2D analysis. Our investigations of the effects of various of parameters on the diagnostic accuracy provided means for the optimal use of the approach.

  4. Sperm volumetric dynamics during in vitro capacitation process in bovine spermatozoa.

    Science.gov (United States)

    García-Herreros, M; Leal, C L V

    2015-06-01

    Previous studies have demonstrated that sperm head morphometry can be used as a potential diagnostic tool for detecting biophysical changes associated with sperm viability in bovine spermatozoa. In this study, sperm head morphometry was used to investigate its value as a biophysical marker for detecting volumetric changes in bovine spermatozoa under in vitro capacitating and non-capacitating incubation conditions. To further test this hypotesis, aliquots of pooled, washed bovine sperm were incubated in either Tyrode's complete medium with heparin (TCMH; a capacitating medium containing Ca2+, NaHCO3 and heparin), Tyrode's complete medium heparin-free (TCM; a medium containing just Ca2+ and NaHCO3) or Tyrode's basal medium (TBM; a non-capacitating medium free of Ca2+, NaHCO3 and heparin, used as control). Aliquots of sperm were processed for morphometric analysis at different incubation-time intervals (0, 3 and 6 h at 38°C), and the chlortetracycline assay was used simultaneously to confirm the ability of the sperm to undergo capacitation (B pattern) and the acrosome reaction (AR pattern) status in each medium. After 3 h of incubation under TCMH conditions, a significant increase was observed in the percentage of B and AR patterns and a significant decrease was found in all sperm morphometric parameters (Psperm size and AR pattern (r=-0.875, Psperm head morphometry can be used as a potential biophysical marker for detecting volumetric changes during capacitation process in bovine spermatozoa.

  5. High-throughput volumetric reconstruction for 3D wheat plant architecture studies

    Directory of Open Access Journals (Sweden)

    Wei Fang

    2016-09-01

    Full Text Available For many tiller crops, the plant architecture (PA, including the plant fresh weight, plant height, number of tillers, tiller angle and stem diameter, significantly affects the grain yield. In this study, we propose a method based on volumetric reconstruction for high-throughput three-dimensional (3D wheat PA studies. The proposed methodology involves plant volumetric reconstruction from multiple images, plant model processing and phenotypic parameter estimation and analysis. This study was performed on 80 Triticum aestivum plants, and the results were analyzed. Comparing the automated measurements with manual measurements, the mean absolute percentage error (MAPE in the plant height and the plant fresh weight was 2.71% (1.08cm with an average plant height of 40.07cm and 10.06% (1.41g with an average plant fresh weight of 14.06g, respectively. The root mean square error (RMSE was 1.37cm and 1.79g for the plant height and plant fresh weight, respectively. The correlation coefficients were 0.95 and 0.96 for the plant height and plant fresh weight, respectively. Additionally, the proposed methodology, including plant reconstruction, model processing and trait extraction, required only approximately 20s on average per plant using parallel computing on a graphics processing unit (GPU, demonstrating that the methodology would be valuable for a high-throughput phenotyping platform.

  6. Volumetric localization of epileptic activities in tuberous sclerosis using synthetic aperture magnetometry

    Energy Technology Data Exchange (ETDEWEB)

    Xiao, Zheng [Hospital for Sick Children, Research Institute, Toronto (Canada); Hospital for Sick Children, Department of Diagnostic Imaging, Toronto (Canada); Xiang, Jing [Hospital for Sick Children, Research Institute, Toronto (Canada); Hospital for Sick Children, Department of Diagnostic Imaging, Toronto (Canada); Holowka, Stephanie; Chuang, Sylvester [Hospital for Sick Children, Department of Diagnostic Imaging, Toronto (Canada); Hunjan, Amrita; Sharma, Rohit; Otsubo, Hiroshi [Hospital for Sick Children, Division of Neurology, Toronto (Canada)

    2006-01-01

    Magnetoencephalography (MEG) is a novel noninvasive technique for localizing epileptic zones. Tuberous sclerosis complex (TSC) is often associated with medically refractory epilepsy with multiple epileptic zones. Surgical treatment of TSC requires accurate localization of epileptogenic tubers. The objective of this study was to introduce a new MEG technique, synthetic aperture magnetometry (SAM), to volumetrically localize irritable zones and clarify the correlations between SAM, dipole modeling and anatomical tubers. Eight pediatric patients with TSC confirmed by clinical and neuroimaging findings were retrospectively studied. MEG data were recorded using a whole-cortex CTF OMEGA system. Sleep deprivation was employed to provoke epileptiform activity. Irritable zones were localized using both dipole modeling and SAM. MRI detected 42 tubers in the eight patients. Dipole modeling localized 28 irritable zones, and 19 out of the 28 zones were near tubers (19/42, 45%). SAM found 51 irritable zones, and 31 out of the 51 zones were near tubers (31/42, 74%). Among the 51 irritable zones determined by SAM, thirty-five zones were in 1-35 Hz, nine zones were in 35-60 Hz, and seven zones were in 60-120 Hz. The new method, SAM, yielded very plausible equivalent sources for patients who showed anatomical tubers on MRI. Compared to conventional dipole modeling, SAM appeared to offer increased detection of irritable zones and beneficial volumetric and frequency descriptions. (orig.)

  7. Volumetric Medical Image Coding: An Object-based, Lossy-to-lossless and Fully Scalable Approach.

    Science.gov (United States)

    Danyali, Habibiollah; Mertins, Alfred

    2011-01-01

    In this article, an object-based, highly scalable, lossy-to-lossless 3D wavelet coding approach for volumetric medical image data (e.g., magnetic resonance (MR) and computed tomography (CT)) is proposed. The new method, called 3DOBHS-SPIHT, is based on the well-known set partitioning in the hierarchical trees (SPIHT) algorithm and supports both quality and resolution scalability. The 3D input data is grouped into groups of slices (GOS) and each GOS is encoded and decoded as a separate unit. The symmetric tree definition of the original 3DSPIHT is improved by introducing a new asymmetric tree structure. While preserving the compression efficiency, the new tree structure allows for a small size of each GOS, which not only reduces memory consumption during the encoding and decoding processes, but also facilitates more efficient random access to certain segments of slices. To achieve more compression efficiency, the algorithm only encodes the main object of interest in each 3D data set, which can have any arbitrary shape, and ignores the unnecessary background. The experimental results on some MR data sets show the good performance of the 3DOBHS-SPIHT algorithm for multi-resolution lossy-to-lossless coding. The compression efficiency, full scalability, and object-based features of the proposed approach, beside its lossy-to-lossless coding support, make it a very attractive candidate for volumetric medical image information archiving and transmission applications.

  8. Volumetric capnography: In the diagnostic work-up of chronic thromboembolic disease

    Directory of Open Access Journals (Sweden)

    Marcos Mello Moreira

    2010-05-01

    Full Text Available Marcos Mello Moreira1, Renato Giuseppe Giovanni Terzi1, Laura Cortellazzi2, Antonio Luis Eiras Falcão1, Heitor Moreno Junior2, Luiz Cláudio Martins2, Otavio Rizzi Coelho21Department of Surgery, 2Department of Internal Medicine, State University of Campinas, School of Medical Sciences, Campinas, Sao Paulo, BrazilAbstract: The morbidity and mortality of pulmonary embolism (PE have been found to be related to early diagnosis and appropriate treatment. The examinations used to diagnose PE are expensive and not always easily accessible. These options include noninvasive examinations, such as clinical pretests, ELISA D-dimer (DD tests, and volumetric capnography (VCap. We report the case of a patient whose diagnosis of PE was made via pulmonary arteriography. The clinical pretest revealed a moderate probability of the patient having PE, and the DD result was negative; however, the VCap associated with arterial blood gases result was positive. The patient underwent all noninvasive exams following admission to hospital and again eight months after discharge. Results gained from invasive tests were similar to those produced by image exams, highlighting the importance of VCap as an important noninvasive tool.Keywords: pulmonary embolism, pulmonary hypertension, volumetric capnography, d-dimers, pretest probability

  9. Cerebrospinal fluid volumetric MRI mapping as a simple measurement for evaluating brain atrophy

    Energy Technology Data Exchange (ETDEWEB)

    Vis, J.B. de; Zwanenburg, J.J.; Kleij, L.A. van der; Spijkerman, J.M.; Hendrikse, J. [University Medical Center Utrecht, Department of Radiology, Utrecht (Netherlands); Biessels, G.J. [University Medical Center Utrecht, Department of Neurology, Brain Center Rudolf Magnus, Utrecht (Netherlands); Petersen, E.T. [University Medical Center Utrecht, Department of Radiology, Utrecht (Netherlands); Hvidovre Hospital, Danish Research Centre for Magnetic Resonance, Hvidovre (Denmark)

    2016-05-15

    To assess whether volumetric cerebrospinal fluid (CSF) MRI can be used as a surrogate for brain atrophy assessment and to evaluate how the T{sub 2} of the CSF relates to brain atrophy. Twenty-eight subjects [mean age 64 (sd 2) years] were included; T{sub 1}-weighted and CSF MRI were performed. The first echo data of the CSF MRI sequence was used to obtain intracranial volume, CSF partial volume was measured voxel-wise to obtain CSF volume (V{sub CSF}) and the T{sub 2} of CSF (T{sub 2,CSF}) was calculated. The correlation between V{sub CSF} / T{sub 2,CSF} and brain atrophy scores [global cortical atrophy (GCA) and medial temporal lobe atrophy (MTA)] was evaluated. Relative total, peripheral subarachnoidal, and ventricular V{sub CSF} increased significantly with increased scores on the GCA and MTA (R = 0.83, 0.78 and 0.78 and R = 0.72, 0.62 and 0.86). Total, peripheral subarachnoidal, and ventricular T{sub 2} of the CSF increased significantly with higher scores on the GCA and MTA (R = 0.72, 0.70 and 0.49 and R = 0.60, 0.57 and 0.41). A fast, fully automated CSF MRI volumetric sequence is an alternative for qualitative atrophy scales. The T{sub 2} of the CSF is related to brain atrophy and could thus be a marker of neurodegenerative disease. (orig.)

  10. A volumetric ablation model of EPDM considering complex physicochemical process in porous structure of char layer

    Science.gov (United States)

    Yang, Liu; Xiao-Jing, Yu; Jian-Ming, Ma; Yi-Wen, Guan; Jiang, Li; Qiang, Li; Sa, Yang

    2017-06-01

    A volumetric ablation model for EPDM (ethylene- propylene-diene monomer) is established in this paper. This model considers the complex physicochemical process in the porous structure of a char layer. An ablation physics model based on a porous structure of a char layer and another model of heterogeneous volumetric ablation char layer physics are then built. In the model, porosity is used to describe the porous structure of a char layer. Gas diffusion and chemical reactions are introduced to the entire porous structure. Through detailed formation analysis, the causes of the compact or loose structure in the char layer and chemical vapor deposition (CVD) reaction between pyrolysis gas and char layer skeleton are introduced. The Arrhenius formula is adopted to determine the methods for calculating carbon deposition rate C which is the consumption rate caused by thermochemical reactions in the char layer, and porosity evolution. The critical porosity value is used as a criterion for char layer porous structure failure under gas flow and particle erosion. This critical porosity value is obtained by fitting experimental parameters and surface porosity of the char layer. Linear ablation and mass ablation rates are confirmed with the critical porosity value. Results of linear ablation and mass ablation rate calculations generally coincide with experimental results, suggesting that the ablation analysis proposed in this paper can accurately reflect practical situations and that the physics and mathematics models built are accurate and reasonable.

  11. Single camera volumetric velocimetry in aortic sinus with a percutaneous valve

    Science.gov (United States)

    Clifford, Chris; Thurow, Brian; Midha, Prem; Okafor, Ikechukwu; Raghav, Vrishank; Yoganathan, Ajit

    2016-11-01

    Cardiac flows have long been understood to be highly three dimensional, yet traditional in vitro techniques used to capture these complexities are costly and cumbersome. Thus, two dimensional techniques are primarily used for heart valve flow diagnostics. The recent introduction of plenoptic camera technology allows for traditional cameras to capture both spatial and angular information from a light field through the addition of a microlens array in front of the image sensor. When combined with traditional particle image velocimetry (PIV) techniques, volumetric velocity data may be acquired with a single camera using off-the-shelf optics. Particle volume pairs are reconstructed from raw plenoptic images using a filtered refocusing scheme, followed by three-dimensional cross-correlation. This technique was applied to the sinus region (known for having highly three-dimensional flow structures) of an in vitro aortic model with a percutaneous valve. Phase-locked plenoptic PIV data was acquired at two cardiac outputs (2 and 5 L/min) and 7 phases of the cardiac cycle. The volumetric PIV data was compared to standard 2D-2C PIV. Flow features such as recirculation and stagnation were observed in the sinus region in both cases.

  12. MobileFusion: real-time volumetric surface reconstruction and dense tracking on mobile phones.

    Science.gov (United States)

    Ondrúška, Peter; Kohli, Pushmeet; Izadi, Shahram

    2015-11-01

    We present the first pipeline for real-time volumetric surface reconstruction and dense 6DoF camera tracking running purely on standard, off-the-shelf mobile phones. Using only the embedded RGB camera, our system allows users to scan objects of varying shape, size, and appearance in seconds, with real-time feedback during the capture process. Unlike existing state of the art methods, which produce only point-based 3D models on the phone, or require cloud-based processing, our hybrid GPU/CPU pipeline is unique in that it creates a connected 3D surface model directly on the device at 25Hz. In each frame, we perform dense 6DoF tracking, which continuously registers the RGB input to the incrementally built 3D model, minimizing a noise aware photoconsistency error metric. This is followed by efficient key-frame selection, and dense per-frame stereo matching. These depth maps are fused volumetrically using a method akin to KinectFusion, producing compelling surface models. For each frame, the implicit surface is extracted for live user feedback and pose estimation. We demonstrate scans of a variety of objects, and compare to a Kinect-based baseline, showing on average ∼ 1.5cm error. We qualitatively compare to a state of the art point-based mobile phone method, demonstrating an order of magnitude faster scanning times, and fully connected surface models.

  13. Deep learning for automatic localization, identification, and segmentation of vertebral bodies in volumetric MR images

    Science.gov (United States)

    Suzani, Amin; Rasoulian, Abtin; Seitel, Alexander; Fels, Sidney; Rohling, Robert N.; Abolmaesumi, Purang

    2015-03-01

    This paper proposes an automatic method for vertebra localization, labeling, and segmentation in multi-slice Magnetic Resonance (MR) images. Prior work in this area on MR images mostly requires user interaction while our method is fully automatic. Cubic intensity-based features are extracted from image voxels. A deep learning approach is used for simultaneous localization and identification of vertebrae. The localized points are refined by local thresholding in the region of the detected vertebral column. Thereafter, a statistical multi-vertebrae model is initialized on the localized vertebrae. An iterative Expectation Maximization technique is used to register the vertebral body of the model to the image edges and obtain a segmentation of the lumbar vertebral bodies. The method is evaluated by applying to nine volumetric MR images of the spine. The results demonstrate 100% vertebra identification and a mean surface error of below 2.8 mm for 3D segmentation. Computation time is less than three minutes per high-resolution volumetric image.

  14. Prior-knowledge treatment planning for volumetric arc therapy using feature-based database mining.

    Science.gov (United States)

    Schreibmann, Eduard; Fox, Tim

    2014-03-06

    Treatment planning for volumetric arc therapy (VMAT) is a lengthy process that requires many rounds of optimizations to obtain the best treatment settings and optimization constraints for a given patient's geometry. We propose a feature-selection search engine that explores previously treated cases of similar anatomy, returning the optimal plan configurations and attainable DVH constraints. Using an institutional database of 83 previously treated cases of prostate carcinoma treated with volumetric-modulated arc therapy, the search procedure first finds the optimal isocenter position with an optimization procedure, then ranks the anatomical similarity as the mean distance between targets. For the best matching plan, the planning information is reformatted to the DICOM format and imported into the treatment planning system to suggest isocenter, arc directions, MLC patterns, and optimization constraints that can be used as starting points in the optimization process. The approach was tested to create prospective treatment plans based on anatomical features that match previously treated cases from the institution database. By starting from a near-optimal solution and using previous optimization constraints, the best matching test only required simple optimization steps to further decrease target inhomogeneity, ultimately reducing time spend by the therapist in planning arcs' directions and lengths.

  15. Concentrated fed-batch cell culture increases manufacturing capacity without additional volumetric capacity.

    Science.gov (United States)

    Yang, William C; Minkler, Daniel F; Kshirsagar, Rashmi; Ryll, Thomas; Huang, Yao-Ming

    2016-01-10

    Biomanufacturing factories of the future are transitioning from large, single-product facilities toward smaller, multi-product, flexible facilities. Flexible capacity allows companies to adapt to ever-changing pipeline and market demands. Concentrated fed-batch (CFB) cell culture enables flexible manufacturing capacity with limited volumetric capacity; it intensifies cell culture titers such that the output of a smaller facility can rival that of a larger facility. We tested this hypothesis at bench scale by developing a feeding strategy for CFB and applying it to two cell lines. CFB improved cell line A output by 105% and cell line B output by 70% compared to traditional fed-batch (TFB) processes. CFB did not greatly change cell line A product quality, but it improved cell line B charge heterogeneity, suggesting that CFB has both process and product quality benefits. We projected CFB output gains in the context of a 2000-L small-scale facility, but the output was lower than that of a 15,000-L large-scale TFB facility. CFB's high cell mass also complicated operations, eroded volumetric productivity, and showed our current processes require significant improvements in specific productivity in order to realize their full potential and savings in manufacturing. Thus, improving specific productivity can resolve CFB's cost, scale-up, and operability challenges.

  16. Evolution in the Volumetric Type Ia Supernova Rate from the Supernova Legacy Survey

    CERN Document Server

    Perrett, K; Conley, A; Gonzalez-Gaitan, S; Carlberg, R; Fouchez, D; Ripoche, P; Neill, J D; Astier, P; Balam, D; Balland, C; Basa, S; Guy, J; Hardin, D; Hook, I M; Howell, D A; Pain, R; Palanque-Delabrouille, N; Pritchet, C; Regnault, N; Rich, J; Ruhlmann-Kleider, V; Baumont, S; Lidman, C; Perlmutter, S; Walker, E S

    2012-01-01

    We present a measurement of