WorldWideScience

Sample records for volumetric air content

  1. Postmortem volumetric CT data analysis of pulmonary air/gas content with regard to the cause of death for investigating terminal respiratory function in forensic autopsy.

    Science.gov (United States)

    Sogawa, Nozomi; Michiue, Tomomi; Ishikawa, Takaki; Kawamoto, Osamu; Oritani, Shigeki; Maeda, Hitoshi

    2014-08-01

    Postmortem CT (PMCT) is useful to investigate air/gas distribution and content in body cavities and viscera. The present study investigated the procedure to estimate total lung air/gas content and aeration ratio as possible indices of terminal respiratory function, using three-dimensional (3-D) PMCT data analysis of forensic autopsy cases without putrefactive gas formation (within 3 days postmortem, n=75), and analyzed the volumetric data with regard to the cause of death. When 3-D bilateral lung images were reconstructed using an image analyzer, combined lung volume was larger in drowning (n=12) than in alcohol/sedative-hypnotic intoxication (n=8) and sudden cardiac death (SCD; n=10), and intermediate in other cases, including mechanical asphyxiation (n=12), fire fatalities due to burns (n=6) and carbon monoxide intoxication (n=7), fatal methamphetamine abuse (n=7), hyperthermia (heatstroke; n=6) and fatal hypothermia (cold exposure; n=7). Air/gas content of the lung as detected using HU interval between -2000 and -400 ('effective' lung aeration areas) and between -2000 and -191 (total lung aeration areas) as well as the ratios to total lung volume ('effective' and total lung aeration ratios, respectively) was higher in mechanical asphyxiation, drowning, fatal burns and hypothermia (cold exposure) than in SCD, and was intermediate in other cases. 'Effective' and total lung aeration ratios may be useful for comparisons between specific causes of death to discriminate between hypothermia (cold exposure) and drug intoxication, and between SCD and other causes of death, respectively. These findings provide interesting insights into potential efficacy of PMCT data analyses of lung volume and CT density as well as lung air/gas content and aeration ratio with regard to the cause of death, as possible indicators of terminal respiratory function, as part of virtual autopsy of the viscera in situ.

  2. Soil volumetric water content measurements using TDR technique

    Directory of Open Access Journals (Sweden)

    S. Vincenzi

    1996-06-01

    Full Text Available A physical model to measure some hydrological and thermal parameters in soils will to be set up. The vertical profiles of: volumetric water content, matric potential and temperature will be monitored in different soils. The volumetric soil water content is measured by means of the Time Domain Reflectometry (TDR technique. The result of a test to determine experimentally the reproducibility of the volumetric water content measurements is reported together with the methodology and the results of the analysis of the TDR wave forms. The analysis is based on the calculation of the travel time of the TDR signal in the wave guide embedded in the soil.

  3. Combustion efficiency and altitude operational limits of three liquid hydrocarbon fuels having high volumetric energy content in a J33 single combustor

    Science.gov (United States)

    Stricker, Edward G

    1950-01-01

    Combustion efficiency and altitude operational limits were determined in a J33 single combustor for AN-F-58 fuel and three liquid hydrocarbon fuels having high volumetric energy content (decalin, tetralin, and monomethylnaphthalene) at simulated altitude and combustor inlet-air conditions. At the conditions investigated, the combustion efficiency for the four fuels generally decreased with an increase in volumetric energy content. The altitude operational limits for decalin and tetralin fuels were higher than for AN-F-58 fuel; monomethylnaphthalene fuel gave the lowest altitude operational limit.

  4. Volumetric water content measurement probes in earth-dam construction

    Directory of Open Access Journals (Sweden)

    Bardanis Michael

    2016-01-01

    Full Text Available Two frequency domain reflectometry (FDR probes have been used. They were used on compacted soils both in the laboratory and in the field. Measurements in the laboratory were intended for calibration. The range of densities and types of materials where insertion of the probes can be achieved was investigated first. The effect of sporadic presence of coarser grains and density on these calibrations, once insertion could be achieved, were investigated second. Measurements on laboratory prepared samples with the same moisture content were different when the sample was kept in the mould from when it was extruded from it. Also both these measurements were different from that in a sample of the same density but significantly larger in diameter. It was found that measurements with these probes are affected by dilation exhibited by soil around the rods of the probes during insertion. Readings immediately after insertion of the sensors on samples extruded from their moulds were the ones closer to measured values. These readings combined with total volume and mass obtained from sand-cone tests during the construction of an earth-dam allowed fairly accurate estimation of the dry unit weight but not the gravimetric water content.

  5. Water content influence on thermal and volumetric properties of wheat starch gelatinization under 10 MPa.

    Science.gov (United States)

    Orlowska, Marta; Randzio, Stanislaw L

    2010-02-01

    A transitiometric in situ analysis of wheat starch aqueous suspensions heated over a temperature range from 285 K to 415 K under isobaric conditions of 10 MPa is presented. Measurements were performed at four selected water concentrations: 56.0%, 64.7%, 73.5%, and 82.4% weight/water. Thermal and volumetric properties and their water content dependencies have been determined for three successive starch phase transformations occurred during wheat starch gelatinization.

  6. Predicting Soil-Water Characteristics from Volumetric Contents of Pore-Size Analogue Particle Fractions

    DEFF Research Database (Denmark)

    Naveed, Muhammad; Møldrup, Per; Tuller, Markus

    (organic matter, clay, silt, fine and coarse sand), variably included in the model depending on the pF value. The volumetric content of a particular soil particle size fraction was included in the model if it was assumed to contribute to the pore size fraction still occupied with water at the given p......F value. Hereby, the Xw*-model implicitly assumes that a given particle size fraction creates an analogue pore size fraction and, also, is based on the validity of the well-known capillary law equation relating equivalent drained pore size to the soil-water matric potential. The Xw*-model was found...... and clay). It performed reasonably well for the dry-end (above a pF value of 2.0; pF = log(|Ψ|), where Ψ is the matric potential in cm), but did not do as well closer to saturated conditions. The Xw*-model gives the volumetric water content as a function of volumetric content of particle size fractions...

  7. Selective-plane illumination microscopy for high-content volumetric biological imaging

    Science.gov (United States)

    McGorty, Ryan; Huang, Bo

    2016-03-01

    Light-sheet microscopy, also named selective-plane illumination microscopy, enables optical sectioning with minimal light delivered to the sample. Therefore, it allows one to gather volumetric datasets of developing embryos and other light-sensitive samples over extended times. We have configured a light-sheet microscope that, unlike most previous designs, can image samples in formats compatible with high-content imaging. Our microscope can be used with multi-well plates or with microfluidic devices. In designing our optical system to accommodate these types of sample holders we encounter large optical aberrations. We counter these aberrations with both static optical components in the imaging path and with adaptive optics. Potential applications of this microscope include studying the development of a large number of embryos in parallel and over long times with subcellular resolution and doing high-throughput screens on organisms or cells where volumetric data is necessary.

  8. Numerical evaluation of an innovative cup layout for open volumetric solar air receivers

    Science.gov (United States)

    Cagnoli, Mattia; Savoldi, Laura; Zanino, Roberto; Zaversky, Fritz

    2016-05-01

    This paper proposes an innovative volumetric solar absorber design to be used in high-temperature air receivers of solar power tower plants. The innovative absorber, a so-called CPC-stacked-plate configuration, applies the well-known principle of a compound parabolic concentrator (CPC) for the first time in a volumetric solar receiver, heating air to high temperatures. The proposed absorber configuration is analyzed numerically, applying first the open-source ray-tracing software Tonatiuh in order to obtain the solar flux distribution on the absorber's surfaces. Next, a Computational Fluid Dynamic (CFD) analysis of a representative single channel of the innovative receiver is performed, using the commercial CFD software ANSYS Fluent. The solution of the conjugate heat transfer problem shows that the behavior of the new absorber concept is promising, however further optimization of the geometry will be necessary in order to exceed the performance of the classical absorber designs.

  9. Determination of Tracer Arrival Times and Volumetric Contents of Clay and Mineral Fines Using Visible NearInfrared Spectroscopy

    DEFF Research Database (Denmark)

    Hermansen, Cecilie; Møldrup, Per; Karup, Dan;

    to give rapid and accurate predictions of soil functional properties related to texture and organic matter, such as water retention and compaction. We evaluated visNIR spectroscopy as a rapid and indirect method for predicting selected BTC tracer mass arrival times (TMATs) and the volumetric contents...... and volumetric contents of clay and mineral fines were correlated to spectral data with partial least squares regression on a calibration set (133 samples) and then tested on a validation set (44 samples). We obtained accurate visNIR predictions of the 5% TMAT and volumetric contents of clay and mineral fines....... VisNIR predictions of later TMATs of 10, 15, 20, 25, 30, 40 and 50% showed decreasing accuracy with increasing TMAT, which probably reflect decreasing correlation with soil texture....

  10. Water and solute transport in agricultural soils predicted by volumetric clay and silt contents

    Science.gov (United States)

    Karup, Dan; Moldrup, Per; Paradelo, Marcos; Katuwal, Sheela; Norgaard, Trine; Greve, Mogens H.; de Jonge, Lis W.

    2016-09-01

    Solute transport through the soil matrix is non-uniform and greatly affected by soil texture, soil structure, and macropore networks. Attempts have been made in previous studies to use infiltration experiments to identify the degree of preferential flow, but these attempts have often been based on small datasets or data collected from literature with differing initial and boundary conditions. This study examined the relationship between tracer breakthrough characteristics, soil hydraulic properties, and basic soil properties. From six agricultural fields in Denmark, 193 intact surface soil columns 20 cm in height and 20 cm in diameter were collected. The soils exhibited a wide range in texture, with clay and organic carbon (OC) contents ranging from 0.03 to 0.41 and 0.01 to 0.08 kg kg- 1, respectively. All experiments were carried out under the same initial and boundary conditions using tritium as a conservative tracer. The breakthrough characteristics ranged from being near normally distributed to gradually skewed to the right along with an increase in the content of the mineral fines (particles ≤ 50 μm). The results showed that the mineral fines content was strongly correlated to functional soil structure and the derived tracer breakthrough curves (BTCs), whereas the OC content appeared less important for the shape of the BTC. Organic carbon was believed to support the stability of the soil structure rather than the actual formation of macropores causing preferential flow. The arrival times of 5% and up to 50% of the tracer mass were found to be strongly correlated with volumetric fines content. Predicted tracer concentration breakthrough points as a function of time up to 50% of applied tracer mass could be well fitted to an analytical solution to the classical advection-dispersion equation. Both cumulative tracer mass and concentration as a function of time were well predicted from the simple inputs of bulk density, clay and silt contents, and applied tracer

  11. Temperature and volumetric water content petrophysical relationships in municipal solid waste for the interpretation of bulk electrical resistivity data

    Science.gov (United States)

    Pilawski, Tamara; Dumont, Gaël; Nguyen, Frédéric

    2015-04-01

    Landfills pose major environmental issues including long-term methane emissions, and local pollution of soil and aquifers but can also be seen as potential energy resources and mining opportunities. Water content in landfills determine whether solid fractions can be separated and recycled, and controls the existence and efficiency of natural or enhanced biodegradation. Geophysical techniques, such as electrical and electromagnetic methods have proven successful in the detection and qualitative investigation of sanitary landfills. However, their interpretation in terms of quantitative water content estimates makes it more challenging due to the influence of parameters such as temperature, compaction, waste composition or pore fluid. To improve the confidence given to bulk electrical resistivity data and to their interpretation, we established temperature and volumetric water content petrophysical relationships that we tested on field and laboratory electrical resistivity measurements. We carried out two laboratory experiments on leachates and waste samples from a landfill located in Mont-Saint-Guibert, Belgium. We determined a first relationship between temperature and electrical resistivity with pure and diluted leachates by progressively increasing the temperature from 5°C to 65°C, and then cooling down to 5°C. The second relationship was obtained by measuring electrical resistivity on waste samples of different volumetric water contents. First, we used the correlations obtained from the experiments to compare electrical resistivity measurements performed in a landfill borehole and on reworked waste samples excavated at different depths. Electrical resistivities were measured every 20cm with an electromagnetic logging device (EM39) while a temperature profile was acquired with optic fibres. Waste samples were excavated every 2m in the same borehole. We filled experimental columns with these samples and measured electrical resistivities at laboratory temperature

  12. A comprehensive optical characterization of a porous open volumetric air receiver in a solar power tower

    CERN Document Server

    Qiu, Yu; He, Ya-Ling; Cheng, Ze-Dong

    2016-01-01

    A comprehensive optical model for a solar power tower with an open volumetric air receiver (OVAR) was developed and validated in this work. Based on the model, the optical characteristics of the OVAR were studied. Firstly, the detailed distributions of the non-uniform solar flux (qsr) on the aperture and the solar source (Ssr) in the OVAR were studied. The incident flux was found to be relatively uniform across the aperture for a single OVAR. However the incident angle of the rays varies between 0o and 42o, which indicates that the parallel assumption of the rays is not appropriate at this condition. Furthermore, the Ssr in the absorber decreases from the inlet to the outlet, and the maximum source (Ssr,max) of 2.414X108 Wm-3 appears at the inlet. Moreover, the Ssr,max was found to appear at the region near the wall rather than the center of the receiver as usual for the combined effect of the non-parallel incident rays and the diffuse reflection on the wall. The revelation of this phenomenon could offer help...

  13. Thermal Performance Evaluation of the 200kWth SolAir Volumetric Solar Receiver

    Energy Technology Data Exchange (ETDEWEB)

    Tellez Sufrategui, F. M.

    2003-07-01

    The goal of the Solair project the design and test of a fully modular, high efficient and durable open volumetric high-flux receiver, which can be easily and safety operated at mean air outlet temperatures of up to 800 degree centigree. The project was thought in two phases, in the first one an advanced 200 kW Hitrec receiver called Solair 200 was designed and tested. The Solair 200 was built like one single receiver module (subassembly), to test the thermal performance of the receiver as well as the receiver module behavior. Out of a set of these receiver modules have been developed to assemble the 3 MWth receiver in the second phase of the project. This report describes the used procedure or methodology for data processing for thermal performance evaluation purposes and the data processing results for the first phase of the project. Test campaign started in March 2002 and produced fifty data sheets (each corresponding to a test day) and ended in February 2003. During the test phase three absorber material types (or configurations) have been tested during the test campaign. The data processing and evaluation results show that performance goals for the receiver have been fully accomplished. Temperatures of more than 800 degree centigree were achieved for the first two configurations in five test days. For the two absorber configurations for which incident solar power was measured the estimated efficiency at 700 degree centigree was 81 ({+-}6)% for configuration 1 and 83({+-}6)% for configuration 2 of the absorber. (Author). 20 refs.

  14. Spatial distribution of bacterial communities on volumetric and planar anodes in single-chamber air-cathode microbial fuel cells

    KAUST Repository

    Vargas, Ignacio T.

    2013-05-29

    Pyrosequencing was used to characterize bacterial communities in air-cathode microbial fuel cells across a volumetric (graphite fiber brush) and a planar (carbon cloth) anode, where different physical and chemical gradients would be expected associated with the distance between anode location and the air cathode. As expected, the stable operational voltage and the coulombic efficiency (CE) were higher for the volumetric anode than the planar anode (0.57V and CE=22% vs. 0.51V and CE=12%). The genus Geobacter was the only known exoelectrogen among the observed dominant groups, comprising 57±4% of recovered sequences for the brush and 27±5% for the carbon-cloth anode. While the bacterial communities differed between the two anode materials, results showed that Geobacter spp. and other dominant bacterial groups were homogenously distributed across both planar and volumetric anodes. This lends support to previous community analysis interpretations based on a single biofilm sampling location in these systems. © 2013 Wiley Periodicals, Inc.

  15. Water and solute transport in agricultural soils predicted by volumetric clay and silt contents

    DEFF Research Database (Denmark)

    Karup, Dan; Møldrup, Per; Paradelo Pérez, Marcos;

    2016-01-01

    . All experiments were carried out under the same initial and boundary conditions using tritium as a conservative tracer. The breakthrough characteristics ranged from being normally distributed to having more preferential characteristics along with an increase in the content of the mineral fines...... (particles ≤ 50 μm). The results showed that the mineral fines content was strongly correlated to functional soil structure and the derived tracer breakthrough curve (BTC), whereas the OC content appeared less important for the shape of the BTC. Organic carbon was believed to support the stability...

  16. Gas phase dispersion in compost as a function of different water contents and air flow rates

    Science.gov (United States)

    Sharma, Prabhakar; Poulsen, Tjalfe G.

    2009-07-01

    Gas phase dispersion in a natural porous medium (yard waste compost) was investigated as a function of gas flow velocity and compost volumetric water content using oxygen and nitrogen as tracer gases. The compost was chosen because it has a very wide water content range and because it represents a wide range of porous media, including soils and biofilter media. Column breakthrough curves for oxygen and nitrogen were measured at relatively low pore gas velocities, corresponding to those observed in for instance soil vapor extraction systems or biofilters for air cleaning at biogas plants or composting facilities. Total gas mechanical dispersion-molecular diffusion coefficients were fitted from the breakthrough curves using a one-dimensional numerical solution to the advection-dispersion equation and used to determine gas dispersivities at different volumetric gas contents. The results showed that gas mechanical dispersion dominated over molecular diffusion with mechanical dispersion for all water contents and pore gas velocities investigated. Importance of mechanical dispersion increased with increasing pore gas velocity and compost water content. The results further showed that gas dispersivity was relatively constant at high values of compost gas-filled porosity but increased with decreasing gas-filled porosity at lower values of gas-filled porosity. Results finally showed that measurement uncertainty in gas dispersivity is generally highest at low values of pore gas velocity.

  17. Chemical Analysis Method for Carbon Bearing Refractory Products——Determination of Magnesium Oxide Content by CyDTA Volumetric Method

    Institute of Scientific and Technical Information of China (English)

    Zhang Xiaohui

    2007-01-01

    @@ GB/T 13246 - 91 1 Scope This standard specifies the method summary, reagents, apparatus, sampling, procedure, test results calculation and permissible tolerance of the determination of magnesium oxide by CyDTA volumetric method. This standard applies to the determination of magnesium oxide content in between 60% and 85% in magnesia-carbon bricks

  18. Effect of volumetric electromagnetic forces on shock wave structure of hypersonic air flow near plate

    Science.gov (United States)

    Fomichev, Vladislav; Yadrenkin, Mikhail; Shipko, Evgeny

    2016-10-01

    Summarizing of experimental studies results of the local MHD-interaction at hypersonic air flow near the plate is presented. Pulsed and radiofrequency discharge have been used for the flow ionization. It is shown that MHD-effect on the shock-wave structure of the flow is significant at test conditions. Using of MHD-interaction parameter enabled to defining characteristic modes of MHD-interaction by the force effect: weak, moderate and strong.

  19. Present and future variations in Antarctic firn air content

    Science.gov (United States)

    Ligtenberg, S.; van den Broeke, M. R.

    2013-12-01

    Detailed knowledge of the properties of the Antarctic firn layer are necessary for the correct interpretation of satellite remote sensing measurements. For example, using a correction for the amount of air content in a firn layer, the total mass of an ice column can be simply deduced from ice sheet surface elevation. However, Antarctic firn air content varies in both space and time and (time-dependent) modelling of the firn layer is therefore needed to assess these variations. Here, we present results from a firn densification model (FDM), that simulates spatial and temporal variability in Antarctic firn air content from the recent past (1979-2012), into the two coming centuries (until 2200). For both time periods, the FDM is forced with climate data from the regional atmospheric climate model RACMO2. Recent seasonal and inter-annual variations in firn air content are mainly caused by the occurrence or absence of large accumulation events. In areas with significant snowmelt, the amount of summer melt also has a major influence on the amount of firn air. In the future simulation, firn air content first increases across the entire ice sheet, as a consequence of increased average precipitation. In coastal areas and on ice shelves, however, the temperature increase and subsequent increase in snowmelt lowers the firn air content during the 22nd century. This also decreases the refreezing capacity of the firn pack in these regions, making them more vulnerable for melt water runoff production.

  20. Improved correlation between CT emphysema quantification and pulmonary function test by density correction of volumetric CT data based on air and aortic density

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Song Soo [Department of Radiology, Chungnam National University Hospital, Chungnam National University School of Medicine (Korea, Republic of); Seo, Joon Beom, E-mail: seojb@amc.seoul.kr [Department of Radiology, University of Ulsan College of Medicine, Asan Medical Center (Korea, Republic of); Kim, Namkug; Chae, Eun Jin [Department of Radiology, University of Ulsan College of Medicine, Asan Medical Center (Korea, Republic of); Lee, Young Kyung [Department of Radiology, Kyung Hee University Hospital at Gangdong (Korea, Republic of); Oh, Yeon Mok; Lee, Sang Do [Division of Pulmonology, Department of Internal Medicine, University of Ulsan College of Medicine, Asan Medical Center (Korea, Republic of)

    2014-01-15

    Objectives: To determine the improvement of emphysema quantification with density correction and to determine the optimal site to use for air density correction on volumetric computed tomography (CT). Methods: Seventy-eight CT scans of COPD patients (GOLD II–IV, smoking history 39.2 ± 25.3 pack-years) were obtained from several single-vendor 16-MDCT scanners. After density measurement of aorta, tracheal- and external air, volumetric CT density correction was conducted (two reference values: air, −1000 HU/blood, +50 HU). Using in-house software, emphysema index (EI) and mean lung density (MLD) were calculated. Differences in air densities, MLD and EI prior to and after density correction were evaluated (paired t-test). Correlation between those parameters and FEV{sub 1} and FEV{sub 1}/FVC were compared (age- and sex adjusted partial correlation analysis). Results: Measured densities (HU) of tracheal- and external air differed significantly (−990 ± 14, −1016 ± 9, P < 0.001). MLD and EI on original CT data, after density correction using tracheal- and external air also differed significantly (MLD: −874.9 ± 27.6 vs. −882.3 ± 24.9 vs. −860.5 ± 26.6; EI: 16.8 ± 13.4 vs. 21.1 ± 14.5 vs. 9.7 ± 10.5, respectively, P < 0.001). The correlation coefficients between CT quantification indices and FEV{sub 1}, and FEV{sub 1}/FVC increased after density correction. The tracheal air correction showed better results than the external air correction. Conclusion: Density correction of volumetric CT data can improve correlations of emphysema quantification and PFT.

  1. Method to Estimate the Dissolved Air Content in Hydraulic Fluid

    Science.gov (United States)

    Hauser, Daniel M.

    2011-01-01

    In order to verify the air content in hydraulic fluid, an instrument was needed to measure the dissolved air content before the fluid was loaded into the system. The instrument also needed to measure the dissolved air content in situ and in real time during the de-aeration process. The current methods used to measure the dissolved air content require the fluid to be drawn from the hydraulic system, and additional offline laboratory processing time is involved. During laboratory processing, there is a potential for contamination to occur, especially when subsaturated fluid is to be analyzed. A new method measures the amount of dissolved air in hydraulic fluid through the use of a dissolved oxygen meter. The device measures the dissolved air content through an in situ, real-time process that requires no additional offline laboratory processing time. The method utilizes an instrument that measures the partial pressure of oxygen in the hydraulic fluid. By using a standardized calculation procedure that relates the oxygen partial pressure to the volume of dissolved air in solution, the dissolved air content is estimated. The technique employs luminescent quenching technology to determine the partial pressure of oxygen in the hydraulic fluid. An estimated Henry s law coefficient for oxygen and nitrogen in hydraulic fluid is calculated using a standard method to estimate the solubility of gases in lubricants. The amount of dissolved oxygen in the hydraulic fluid is estimated using the Henry s solubility coefficient and the measured partial pressure of oxygen in solution. The amount of dissolved nitrogen that is in solution is estimated by assuming that the ratio of dissolved nitrogen to dissolved oxygen is equal to the ratio of the gas solubility of nitrogen to oxygen at atmospheric pressure and temperature. The technique was performed at atmospheric pressure and room temperature. The technique could be theoretically carried out at higher pressures and elevated

  2. Bubble Content in Air/Hydro System--Part 2:Factors Influencing Bubble Content

    Institute of Scientific and Technical Information of China (English)

    2000-01-01

    A new method for measuring bubble content of two-phase fluids in complex systems such as air/hydro systems has been designed and verified. Some new results of the study on the factors influencing bubble content using this new method are given in this paper, including the results of the experiments in the SKIP-valve system and long-tube system. Results indicate that the operating time, opening of the control-valve, air supply pressure, mass of the load, speed ratio, and the length of the tube all affect bubble content.

  3. 容量法快速测定锰矿中二氧化硅含量%Determination of Silicon Dioxide Content in Manganese Ore by Volumetric Method

    Institute of Scientific and Technical Information of China (English)

    张慤; 邓军华; 王一凌; 王翠艳; 曲月华

    2012-01-01

    At present, fluoride potassium silicate Volumetric method analysis silica content in manganese ore has not reported, through experiments optimized the parameters of fluoride potassium silicate Volumetric method: melt-like way, sample weight, volume of acidified et. It can complete the rapid determination of silicon dioxide content in manganese ore. Measurement Results consistent with the certified value and the analysis to satisfy the GB/T 1509 - 2006 permission deviation request, The relative standard deviation of measurement results are less than 1 % .%目前利用氟硅酸钾容量法测定锰矿中二氧化硅含量还没有报道.采用硅氟酸钾容量法,通过称样量、融样方式、酸化体积等条件进行优化实验,实现了容量法快速测定锰矿中二氧化硅的含量.实验数据的相对标准偏差小于1%.测量值与认定值一致,测量结果满足GB/T 1509-2006《锰矿石 硅含量的测定 高氯酸脱水重量法》允许差的要求.

  4. Bubble Content in Air/Hydro System--Part 1:Measurement of Bubble Content

    Institute of Scientific and Technical Information of China (English)

    2000-01-01

    The mechanism of bubble formation in air/hydro systems is investigated. Results presented in this paper include further insight into the mechanism of bubble formation and the measurement of bubble content. The regularity of bubble transport in the system is found, with an idea for a new method for separating gas from oil. The method has been verified experimentally with favorable results.

  5. Evaluation of ergosterol content in the air of various environments.

    Science.gov (United States)

    Gutarowska, Beata; Skóra, Justyna; Pielech-Przybylska, Katarzyna

    The aim of the study was to compare the content of ergosterol in different microorganisms (bacteria, yeasts and moulds) isolated from the air as well as in six species of moulds in their different morphological forms-live mycelium, dead mycelium, and spores. Evaluation of the level of mould contamination of the air in various places using culture method and ergosterol determination was also performed. The analysis of ergosterol was carried out by gas chromatography equipped with flame ionisation detector. For evaluation of the results, analysis of variance and multiple comparison test were used. The quantity of ergosterol in the spores of various species of mould was in the range 1.9-9.4 pg/spore. The presence of yeasts and bacteria in the air does not significantly affect ergosterol concentration, in view of the low content of that sterol in their cells (max. 0.009 pg/cell for bacteria and 0.39 pg/cell for yeast). An ergosterol concentration above 1 ng per m(3) can be considered an indicator of excessive mould contamination of indoor air. Based on determination of ergosterol in the air of mouldy rooms the result obtained may be compared with the culture method, due to the 1,000 times higher concentration of ergosterol in the mycelium compared with spores. However, in the analysis of outdoor air, in view of the presence of mould mainly in the form of spores and the degradation of ergosterol by UV radiation, analysis of that compound may indicate a lower level of contamination compared with the culture method.

  6. A coupled melt-freeze temperature index approach in a one-layer model to predict bulk volumetric liquid water content dynamics in snow

    Science.gov (United States)

    Avanzi, Francesco; Yamaguchi, Satoru; Hirashima, Hiroyuki; De Michele, Carlo

    2016-04-01

    Liquid water in snow rules runoff dynamics and wet snow avalanches release. Moreover, it affects snow viscosity and snow albedo. As a result, measuring and modeling liquid water dynamics in snow have important implications for many scientific applications. However, measurements are usually challenging, while modeling is difficult due to an overlap of mechanical, thermal and hydraulic processes. Here, we evaluate the use of a simple one-layer one-dimensional model to predict hourly time-series of bulk volumetric liquid water content in seasonal snow. The model considers both a simple temperature-index approach (melt only) and a coupled melt-freeze temperature-index approach that is able to reconstruct melt-freeze dynamics. Performance of this approach is evaluated at three sites in Japan. These sites (Nagaoka, Shinjo and Sapporo) present multi-year time-series of snow and meteorological data, vertical profiles of snow physical properties and snow melt lysimeters data. These data-sets are an interesting opportunity to test this application in different climatic conditions, as sites span a wide latitudinal range and are subjected to different snow conditions during the season. When melt-freeze dynamics are included in the model, results show that median absolute differences between observations and predictions of bulk volumetric liquid water content are consistently lower than 1 vol%. Moreover, the model is able to predict an observed dry condition of the snowpack in 80% of observed cases at a non-calibration site, where parameters from calibration sites are transferred. Overall, the analysis show that a coupled melt-freeze temperature-index approach may be a valid solution to predict average wetness conditions of a snow cover at local scale.

  7. Investigation of Proprietary Air-Entraining Admixtures to Produce Frost- Resistant Concrete with Low Air Content

    Science.gov (United States)

    1992-03-01

    given air content, a higher specific surface should result in a smaller spacing factor ( Mindess and Young 1981). Therefore, if a particular AEA produced...MS. Mindess , S., and Young, J. F. 1981. Concrete, Prentice-Hall, Englewood Cliffs, NJ. Powers, T. C. 1954 (May). "Void Spacing as a Basis for

  8. Ground penetrating radar for determining volumetric soil water content ; results of comparative measurements at two test sites

    NARCIS (Netherlands)

    Overmeeren, R.A. van; Sariowan, S.V.; Gehrels, J.C.

    1997-01-01

    Ground penetrating radar (GPR) can provide information on the soil water content of the unsaturated zone in sandy deposits via measurements from the surface, and so avoids drilling. Proof of this was found from measurements of radar wave velocities carried out ten times over 13 months at two test si

  9. Volumetric composition of nanocomposites

    DEFF Research Database (Denmark)

    Madsen, Bo; Lilholt, Hans; Mannila, Juha

    2015-01-01

    Detailed characterisation of the properties of composite materials with nanoscale fibres is central for the further progress in optimization of their manufacturing and properties. In the present study, a methodology for the determination and analysis of the volumetric composition of nanocomposites...... is presented, using cellulose/epoxy and aluminosilicate/polylactate nanocomposites as case materials. The buoyancy method is used for the accurate measurements of materials density. The accuracy of the method is determined to be high, allowing the measured nanocomposite densities to be reported with 5...... significant figures. The plotting of the measured nanocomposite density as a function of the nanofibre weight content is shown to be a first good approach of assessing the porosity content of the materials. The known gravimetric composition of the nanocomposites is converted into a volumetric composition...

  10. Influence of water air content on cavitation erosion in distilled water

    CSIR Research Space (South Africa)

    Auret, JG

    1993-12-01

    Full Text Available air content on cavitation erosion in distilled water J. G. Auret,* O. F. R. A. Damm,* G. J. Wright* and F. P. A. Robinson t The influence of increased air content of the cavitating liquid (distilled water... erosion, air (gas) content, distilled water Introduction The existence of cavitation at positive liquid pressures depends on the presence of small gas pockets or nuclei ~. Thus gas (usually air) content is an extremely...

  11. Error Analysis of Clay-Rock Water Content Estimation with Broadband High-Frequency Electromagnetic Sensors—Air Gap Effect

    Directory of Open Access Journals (Sweden)

    Thierry Bore

    2016-04-01

    Full Text Available Broadband electromagnetic frequency or time domain sensor techniques present high potential for quantitative water content monitoring in porous media. Prior to in situ application, the impact of the relationship between the broadband electromagnetic properties of the porous material (clay-rock and the water content on the frequency or time domain sensor response is required. For this purpose, dielectric properties of intact clay rock samples experimental determined in the frequency range from 1 MHz to 10 GHz were used as input data in 3-D numerical frequency domain finite element field calculations to model the one port broadband frequency or time domain transfer function for a three rods based sensor embedded in the clay-rock. The sensor response in terms of the reflection factor was analyzed in time domain with classical travel time analysis in combination with an empirical model according to Topp equation, as well as the theoretical Lichtenecker and Rother model (LRM to estimate the volumetric water content. The mixture equation considering the appropriate porosity of the investigated material provide a practical and efficient approach for water content estimation based on classical travel time analysis with the onset-method. The inflection method is not recommended for water content estimation in electrical dispersive and absorptive material. Moreover, the results clearly indicate that effects due to coupling of the sensor to the material cannot be neglected. Coupling problems caused by an air gap lead to dramatic effects on water content estimation, even for submillimeter gaps. Thus, the quantitative determination of the in situ water content requires careful sensor installation in order to reach a perfect probe clay rock coupling.

  12. Error Analysis of Clay-Rock Water Content Estimation with Broadband High-Frequency Electromagnetic Sensors--Air Gap Effect.

    Science.gov (United States)

    Bore, Thierry; Wagner, Norman; Lesoille, Sylvie Delepine; Taillade, Frederic; Six, Gonzague; Daout, Franck; Placko, Dominique

    2016-04-18

    Broadband electromagnetic frequency or time domain sensor techniques present high potential for quantitative water content monitoring in porous media. Prior to in situ application, the impact of the relationship between the broadband electromagnetic properties of the porous material (clay-rock) and the water content on the frequency or time domain sensor response is required. For this purpose, dielectric properties of intact clay rock samples experimental determined in the frequency range from 1 MHz to 10 GHz were used as input data in 3-D numerical frequency domain finite element field calculations to model the one port broadband frequency or time domain transfer function for a three rods based sensor embedded in the clay-rock. The sensor response in terms of the reflection factor was analyzed in time domain with classical travel time analysis in combination with an empirical model according to Topp equation, as well as the theoretical Lichtenecker and Rother model (LRM) to estimate the volumetric water content. The mixture equation considering the appropriate porosity of the investigated material provide a practical and efficient approach for water content estimation based on classical travel time analysis with the onset-method. The inflection method is not recommended for water content estimation in electrical dispersive and absorptive material. Moreover, the results clearly indicate that effects due to coupling of the sensor to the material cannot be neglected. Coupling problems caused by an air gap lead to dramatic effects on water content estimation, even for submillimeter gaps. Thus, the quantitative determination of the in situ water content requires careful sensor installation in order to reach a perfect probe clay rock coupling.

  13. Error Analysis of Clay-Rock Water Content Estimation with Broadband High-Frequency Electromagnetic Sensors—Air Gap Effect

    Science.gov (United States)

    Bore, Thierry; Wagner, Norman; Delepine Lesoille, Sylvie; Taillade, Frederic; Six, Gonzague; Daout, Franck; Placko, Dominique

    2016-01-01

    Broadband electromagnetic frequency or time domain sensor techniques present high potential for quantitative water content monitoring in porous media. Prior to in situ application, the impact of the relationship between the broadband electromagnetic properties of the porous material (clay-rock) and the water content on the frequency or time domain sensor response is required. For this purpose, dielectric properties of intact clay rock samples experimental determined in the frequency range from 1 MHz to 10 GHz were used as input data in 3-D numerical frequency domain finite element field calculations to model the one port broadband frequency or time domain transfer function for a three rods based sensor embedded in the clay-rock. The sensor response in terms of the reflection factor was analyzed in time domain with classical travel time analysis in combination with an empirical model according to Topp equation, as well as the theoretical Lichtenecker and Rother model (LRM) to estimate the volumetric water content. The mixture equation considering the appropriate porosity of the investigated material provide a practical and efficient approach for water content estimation based on classical travel time analysis with the onset-method. The inflection method is not recommended for water content estimation in electrical dispersive and absorptive material. Moreover, the results clearly indicate that effects due to coupling of the sensor to the material cannot be neglected. Coupling problems caused by an air gap lead to dramatic effects on water content estimation, even for submillimeter gaps. Thus, the quantitative determination of the in situ water content requires careful sensor installation in order to reach a perfect probe clay rock coupling. PMID:27096865

  14. Present and future variations in Antarctic firn air content

    Directory of Open Access Journals (Sweden)

    S. R. M. Ligtenberg

    2014-01-01

    Full Text Available A firn densification model (FDM is used to assess spatial and temporal (1979–2200 variations in the depth, density and temperature of the firn layer covering the Antarctic ice sheet (AIS. Results from a time-dependent version of the FDM are compared to more commonly used steady-state FDM results. Although the average AIS firn air content (FAC between both models is similar (22.5 m, large spatial differences are found: in the ice-sheet interior, the steady-state model underestimates the FAC by up to 2 m, while the FAC is overestimated by 5–15 m along the ice-sheet margins, due to significant surface melt. Applying the steady-state FAC values to convert surface elevation to ice thickness (i.e. assuming flotation at the grounding line potentially results in an underestimation of ice discharge at the grounding line, and hence an underestimation of current AIS mass loss by 23.5%, or 16.7 Gt yr−1 (with regard to the reconciled estimate over 1992–2011, Shepherd et al., 2012. The timing of the measurement is also important as temporal FAC variations of 1–2 m are simulated within the 33 yr period. Until 2200, the Antarctic FAC is projected to change due to a combination of increasing accumulation, temperature and surface melt. The latter two result in a decrease of FAC, due to (i more refrozen meltwater, (ii a higher densification rate and (iii a faster firn-to-ice transition at the bottom of the firn layer. These effects are however more than compensated by increasing snowfall, leading to a 4–14% increase in FAC. Only in melt-affected regions, future FAC is simulated to decrease, with the largest changes (−50 to −80% on the ice shelves in the Antarctic Peninsula and Dronning Maud Land. Integrated over the AIS, increased precipitation results in a combined ice and air volume increase of ∼300 km3 yr−1 until 2100, equivalent to an elevation change of +2.1 cm yr−1. This shows that variations in firn depth remain important to consider

  15. Present and future variations in Antarctic firn air content

    Science.gov (United States)

    Ligtenberg, S. R. M.; Kuipers Munneke, P.; van den Broeke, M. R.

    2014-09-01

    A firn densification model (FDM) is used to assess spatial and temporal (1979-2200) variations in the depth, density and temperature of the firn layer covering the Antarctic ice sheet (AIS). A time-dependent version of the FDM is compared to more commonly used steady-state FDM results. Although the average AIS firn air content (FAC) of both models is similar (22.5 m), large spatial differences are found: in the ice-sheet interior, the steady-state model underestimates the FAC by up to 2 m, while the FAC is overestimated by 5-15 m along the ice-sheet margins, due to significant surface melt. Applying the steady-state FAC values to convert surface elevation to ice thickness (i.e., assuming flotation at the grounding line) potentially results in an underestimation of ice discharge at the grounding line, and hence an underestimation of current AIS mass loss by 23.5% (or 16.7 Gt yr-1) with regard to the reconciled estimate over the period 1992-2011. The timing of the measurement is also important, as temporal FAC variations of 1-2 m are simulated within the 33 yr period (1979-2012). Until 2200, the Antarctic FAC is projected to change due to a combination of increasing accumulation, temperature, and surface melt. The latter two result in a decrease of FAC, due to (i) more refrozen meltwater, (ii) a higher densification rate, and (iii) a faster firn-to-ice transition at the bottom of the firn layer. These effects are, however, more than compensated for by increasing snowfall, leading to a 4-14% increase in FAC. Only in melt-affected regions, future FAC is simulated to decrease, with the largest changes (-50 to -80%) on the ice shelves in the Antarctic Peninsula and Dronning Maud Land. Integrated over the AIS, the increase in precipitation results in a similar volume increase due to ice and air (both ~150 km3 yr-1 until 2100). Combined, this volume increase is equivalent to a surface elevation change of +2.1 cm yr-1, which shows that variations in firn depth remain

  16. Illicit psychotropic substance contents in the air of Italy

    Science.gov (United States)

    Cecinato, Angelo; Balducci, Catia; Budetta, Valentina; Pasini, Antonello

    2010-06-01

    Two in-field campaigns were performed in 2009 to elucidate the contents of illicit psychotropic substances in airborne particulates of Italian cities. Twenty-eight localities of eight Italian regions were investigated in winter, and further eleven sites in June (14 regions in total), thanks to contribution of Regional Environmental Agencies. Cocaine was found almost everywhere, although some sites were rural or suburban. The maximum was recorded in Milan in winter (˜0.39 ng m -3), and "high" values (up to ˜0.16 ng m -3) in other Northern cities and in Rome. Besides cocaine, three cannabinoids will be monitored, namely Δ 9-tetrahydrocannabinol, cannabidiol and cannabinol. The three compounds often affected the air at lower extents than cocaine, and sometimes resulted absent. Cannabinol accounted for up to 90% of the total. The concentrations of illicit compounds were up to six times lower in June than in winter. This decrease was probably induced by the lowering of boundary layer height typical of winter, and by the oxidizing capacity of atmosphere, which is stronger in the warm season. Compared to n-alkanes, polynuclear aromatic compounds, nicotine, caffeine and airborne particulate, cocaine seemed to follow a peculiar behaviour; in fact, meaningful (≥0.80) Pearson (linear) regression coefficients were calculated from the corresponding concentrations only at local scale (e.g. Rome), and within just one season. Improvements of the method are needed to monitor illicit drug metabolites (e.g. benzoylecgonine, ecgonine methyl ester, 9-carboxy-11-nor-Δ 9-tetrahydrocannabinol), heroin and semi-volatile amphetamines.

  17. A Simple Experiment To Measure the Content of Oxygen in the Air Using Heated Steel Wool

    Science.gov (United States)

    Vera, Francisco; Rivera, Rodrigo; Nunez, Cesar

    2011-01-01

    The typical experiment to measure the oxygen content in the atmosphere uses the rusting of steel wool inside a closed volume of air. Two key aspects of this experiment that make possible a successful measurement of the content of oxygen in the air are the use of a closed atmosphere and the use of a chemical reaction that involves the oxidation of…

  18. Multivariate analysis comparing microbial air content of an air-conditioned building and a naturally ventilated building over one year

    Science.gov (United States)

    Parat, Sylvie; Perdrix, Alain; Fricker-Hidalgo, Hélène; Saude, Isabelle; Grillot, Renee; Baconnier, Pierre

    Heating, ventilation and air-conditioning (HVAC) may be responsible for the production and spread of airborne microorganisms in office buildings. In order to compare airborne microbiological flora in an air-conditioned building with that in a naturally ventilated building, eight sets of measurements were made over a 1-year period. Concurrently with other environmental measurements, air samples were collected in each building, from three offices and from the outdoor air, using the Andersen single-stage sampler. Three different media were used to culture fungi, staphylococci and mesophilic bacteria. Multivariate analysis revealed a group of offices more contaminated than others, and a marked seasonal variation in fungal concentrations. A comparison of mean levels of microorganisms measured in the two buildings showed that the air microbial content was significantly higher and more variable in the naturally ventilated building than in the air-conditioned building. Moreover, in the naturally ventilated building, the interior fungal content was strongly dependent on the outdoor content, while in the air-conditioned building fungal concentrations remained constant despite significant variations measured outside. This was confirmed by a statistical comparison of the correlation coefficients between indoor and outdoor concentrations. No difference was observed regarding gaseous pollutants and temperature, but relative humidity was significantly higher in the air-conditioned building. The effect of HVAC was to prevent the intake of outdoor particles and to dilute the indoor concentrations. These results are consistent with the presence of high-efficiency filters and a steam humidifier in the HVAC system under study.

  19. Uncertainty evaluation for determination of fluorine content by distillation-thorium nitrate volumetric method%蒸馏-硝酸钍容量法测定氟含量不确定度评定

    Institute of Scientific and Technical Information of China (English)

    张小霞

    2013-01-01

    The uncertainty sources in determination of fluorine content of cryolite and aluminium fluoride by distillation-thorium nitrate volumetric method were analyzed.Evaluation for the uncertainty of each component was carried out by establishing the mathematic model,and the expanded uncertainty of fluorine content determination with distillation-thorium nitrate volumetric method was also calculated.Experimental principle:melt the sample with anhydrous sodium carbonate,separate fluoride through sulfuric acid-water vapor distillation,taking sodium alizarin sulfonate and methylene blue as indicators,using thorium nitrate standard solution to titrate fluorine content in the sample.Evaluation results indicated that,the expanded uncertainty of thorium nitrate volumetric method for the determination of fluorine content was 0.42%.%对蒸馏-硝酸钍容量法测定冰晶石及氟化铝中氟含量的不确定度来源进行分析,通过建立数学模型,评定各分量的不确定度,并计算蒸馏-硝酸钍容量法测定氟元素含量的扩展不确定度.实验原理:试样用无水碳酸钠熔融,经硫酸-水蒸气蒸馏分离氟后,以茜素磺酸钠和次甲基蓝作指示剂,用硝酸钍标准溶液滴定测定样品中氟含量.评定结果表明,蒸馏-硝酸钍容量法测定氟含量结果的扩展不确定度为0.42%.

  20. Volumetric Virtual Environments

    Institute of Scientific and Technical Information of China (English)

    HE Taosong

    2000-01-01

    Driven by fast development of both virtual reality and volume visualization, we discuss some critical techniques towards building a volumetric VR system, specifically the modeling, rendering, and manipulations of a volumetric scene.Techniques such as voxel-based object simplification, accelerated volume rendering,fast stereo volume rendering, and volumetric "collision detection" are introduced and improved, with the idea of demonstrating the possibilities and potential benefits of incorporating volumetric models into VR systems.

  1. Bone lead (Pb) content at the tibia is associated with thinner distal tibia cortices and lower volumetric bone density in postmenopausal women.

    Science.gov (United States)

    Wong, Andy K O; Beattie, Karen A; Bhargava, Aakash; Cheung, Marco; Webber, Colin E; Chettle, David R; Papaioannou, Alexandra; Adachi, Jonathan D

    2015-10-01

    Conflicting evidence suggests that bone lead or blood lead may reduce areal bone mineral density (BMD). Little is known about how lead at either compartment affects bone structure. This study examined postmenopausal women (N=38, mean age 76 ± 8, body mass index (BMI): 26.74 ± 4.26 kg/m(2)) within the Hamilton cohort of the Canadian Multicentre Osteoporosis Study (CaMos), measuring bone lead at 66% of the non-dominant leg and at the calcaneus using (109)Cadmium X-ray fluorescence. Volumetric BMD and structural parameters were obtained from peripheral quantitative computed tomography images (200 μm in-plane resolution, 2.3 ± 0.5mm slice thickness) of the same 66% site and of the distal 4% site of the tibia length. Blood lead was measured using atomic absorption spectrometry and blood-to-bone lead partition coefficients (PBB, log ratio) were computed. Multivariable linear regression examined each of bone lead at the 66% tibia, calcaneus, blood lead and PBB as related to each of volumetric BMD and structural parameters, adjusting for age and BMI, diabetes or antiresorptive therapy. Regression coefficients were reported along with 95% confidence intervals. Higher amounts of bone lead at the tibia were associated with thinner distal tibia cortices (-0.972 (-1.882, -0.061) per 100 μg Pb/g of bone mineral) and integral volumetric BMD (-3.05 (-6.05, -0.05) per μg Pb/g of bone mineral). A higher PBB was associated with larger trabecular separation (0.115 (0.053, 0.178)), lower trabecular volumetric BMD (-26.83 (-50.37, -3.29)) and trabecular number (-0.08 (-0.14, -0.02)), per 100 μg Pb/g of bone mineral after adjusting for age and BMI, and remained significant while accounting for diabetes or use of antiresorptives. Total lead exposure activities related to bone lead at the calcaneus (8.29 (0.11, 16.48)) and remained significant after age and antiresorptives-adjustment. Lead accumulated in bone can have a mild insult on bone structure; but greater partitioning of lead

  2. Natural radioactivity content in soil and indoor air of Chellanam.

    Science.gov (United States)

    Mathew, S; Rajagopalan, M; Abraham, J P; Balakrishnan, D; Umadevi, A G

    2012-11-01

    Contribution of terrestrial radiation due to the presence of naturally occurring radionuclides in soil and air constitutes a significant component of the background radiation exposure to the population. The concentrations of natural radionuclides in the soil and indoor air of Chellanam were investigated with an aim of evaluating the environmental radioactivity level and radiation hazard to the population. Chellanam is in the suburbs of Cochin, with the Arabian Sea in the west and the Cochin backwaters in the east. Chellanam is situated at ∼25 km from the sites of these factories. The data obtained serve as a reference in documenting changes to the environmental radioactivity due to technical activities. Soil samples were collected from 30 locations of the study area. The activity concentrations of (232)Th, (238)U and (40)K in the samples were analysed using gamma spectrometry. The gamma dose rates were calculated using conversion factors recommended by UNSCEAR [United Nations Scientific Committee on the Effects of Atomic Radiation. Sources and effects of ionizing radiation. UNSCEAR (2000)]. The ambient radiation exposure rates measured in the area ranged from 74 to 195 nGy h(-1) with a mean value of 131 nGy h(-1). The significant radionuclides being (232)Th, (238)U and (40)K, their activities were used to arrive at the absorbed gamma dose rate with a mean value of 131 nGy h(-1) and the radium equivalent activity with a mean value of 162 Bq kg(-1). The radon progeny levels varied from 0.21 to 1.4 mWL with a mean value of 0.6 mWL. The thoron progeny varied from 0.34 to 2.9 mWL with a mean value of 0.85 mWL. The ratio between thoron and radon progenies varied from 1.4 to 2.3 with a mean of 1.6. The details of the study, analysis and results are discussed.

  3. Determination, by using GPR, of the volumetric water content in structures, sub-structures, foundations and soil - ongoing activities in Working Project 2.5 of COST Action TU1208

    Science.gov (United States)

    Tosti, Fabio; Slob, Evert

    2015-04-01

    This work will endeavour to review the current status of research activities carried out in Working Project 2.5 'Determination, by using GPR, of the volumetric water content in structures, sub-structures, foundations and soil' within the framework of Working Group 2 'GPR surveying of pavements, bridges, tunnels and buildings; underground utility and void sensing' of the COST (European COoperation in Science and Technology) Action TU1208 'Civil Engineering Applications of Ground Penetrating Radar' (www.GPRadar.eu). Overall, the Project includes 55 Participants from over 21 countries representing 33 Institutions. By considering the type of Institution, a percentage of 64% (35 units) comes from the academic world, while Research Centres and Companies include, respectively, the 27% (15 units) and 9% (5 units) of Institutions. Geographically speaking, Europe is the continent most represented with 18 out of 21 countries, followed by Africa (2 countries) and Asia (1 country). In more details and according to the Europe sub-regions classification provided by the United Nations, Southern Europe includes 39% of countries, Western Europe 27%, while Northern and Eastern Europe are equally present with 17% of countries each. Relying on the main purpose of Working Project 2.5, namely, the ground-penetrating radar-based evaluation of volumetric water content in structures, substructures , foundations, and soils, four main issues have been overall addressed over the first two years of activities. The first one, has been related to provide a comprehensive state of the art on the topic, due to the wide-ranging applications covered in the main disciplines of civil engineering, differently demanding. In this regard, two main publications reviewing the state of the art have been produced [1,2]. Secondly, discussions among Working Group Chairs and other Working Project Leaders have been undertaken and encouraged to avoid the risk of overlapping amongst similar topics from other Working

  4. Effect of air moisture content on adhesion to dentine: a comparison of dental air/water syringe tips.

    Science.gov (United States)

    Lau, A; Bennani, V; Chandler, N; Hanlin, S; Lowe, B

    2014-09-01

    This study aimed to evaluate the spray pattern and air moisture content produced by single-use syringe and multiple-use syringe tips. The drying efficacy was evaluated by analyzing the spray and by detecting the presence of moisture in the air blast through the tips. Single-use tips had a more consistent spray pattern and produced a moisture-free airflow compared to the multiple-use tips. The differences were statistically significant. Adhesion to dentine between tooth preparations dried with the two tips was evaluated using a tensile test. The differences were statistically insignificant.

  5. Study on Volumetric Moisture Content of Soil Shallow Landslide during Precipitation Process%降雨过程中土质浅层滑体体积含水量变化研究

    Institute of Scientific and Technical Information of China (English)

    李凤琴

    2012-01-01

    Precipitation is one of the main inducing factors to landslide geological hazard, especially for the soil landslide. During the last rainfall process, the shallow part of the soil landslide will he saturated immediately and the temporary saturated zone is formed, which would lead the matric suction of the shallow landslide body reduction and slipping. While, the volumetric moisture content is the main index reflecting the variation of temporary saturated zone.Taking the participation-induced soil shallow landslide as an example in this paper, the temporary saturated zone of shallow landslide body was simulated by the Geo-slope software during 6d last rainfall. Meanwhile, the 4 points' volumetric moisture contents are analyzed from the back of the landslide to the front, which are near the slope surface and their depths are less than 5m, and the landslide stabilities are calculated during 6 days last rainfall. At last, the changing model of volumetric moisture content in soil landslide is put forward when the shallow sliding occurred during the continuous precipitation process.%降雨是滑坡地质灾害的主要诱发因素之一,尤其是对于土质滑坡,连续的降雨能够使得土质滑坡浅表层滑体迅速饱和形成暂态饱和区,从而导致浅表层土质滑体的基质吸力降低,引起浅层滑动,而反映土体中暂态饱和区变化的主要指标为士体体积含水量.该文选取某一降雨诱发型土体滑坡为例,采用Geo-slope软件模拟连续降雨6d条件下土质浅层滑体内的暂态饱和区变化情况,并分析由滑坡后缘至前缘4个靠近地表(深度小于5m)点的体积含水量变化趋势以及连续6d降雨过程中浅层滑体的稳定性变化趋势,提出了降雨人渗过程中土质滑坡发生浅层滑动的体积含水量变化模式.

  6. Summer temperature trend over the past two millennia using air content in Himalayan ice

    Directory of Open Access Journals (Sweden)

    S. Hou

    2007-01-01

    Full Text Available Two Himalayan ice cores display a factor-two decreasing trend of air content over the past two millennia, in contrast to the relatively stable values in Greenland and Antarctica ice cores over the same period. Because the air content can be related with the relative frequency and intensity of melt phenomena, its variations along the Himalayan ice cores provide an indication of summer temperature trend. Our reconstruction point toward an unprecedented warming trend in the 20th century but does not depict the usual trends associated with "Medieval Warm Period" (MWP, or "Little Ice Age" (LIA.

  7. Investigation on the heavy-metal content of zinc-air button cells.

    Science.gov (United States)

    Richter, Andrea; Richter, Silke; Recknagel, Sebastian

    2008-01-01

    Within the framework of a German government project (initiated by the Federal Environment Agency) to check the compliance of commercially available batteries with the German Battery Ordinance concerning their heavy metal contents, 18 different types of commercially available zinc-air button cells were analysed for their cadmium, lead and mercury contents. After microwave assisted dissolution with aqua regia, Cd and Pb were determined using inductively coupled plasma mass spectrometry (ICP-MS), and Hg was determined using inductively coupled plasma optical emission spectrometry (ICP OES) and atomic absorption spectrometry. Cd contents were found to be much lower than the permitted limits; Pb contents were also found to be below the limits. Hg contents were found to be near the limits, and in one case the limit was exceeded.

  8. Online media coverage of air pollution risks and current policies in India: A content analysis.

    Science.gov (United States)

    Murukutla, Nandita; Negi, Nalin S; Puri, Pallavi; Mullin, Sandra; Onyon, Lesley

    2017-09-01

    Background Air pollution is of particular concern in India, which contains 11 of the 20 most polluted cities in the world. Media coverage of air pollution issues plays an important role in influencing public opinion and increasing citizen demand for action on clean air policy. Hence, this study was designed to assess news coverage of air pollution in India and its implications for policy advancement. Methods Articles published online between 1 January 2014 and 31 October 2015 that discussed air pollution in India were systematically content analysed. From 6435 articles in the national media and 271 articles in the international media, a random selection of 500 articles (400 from national and 100 from international media) were analysed and coded by two independent coders, after high inter-rater reliability (kappa statistic above 0.8) was established. Results There was an increase in the number of news stories on air pollution in India in the national media over the study period; 317 (63%) stories described the risk to health from air pollution as moderately to extremely severe, and 393 (79%) stories described the situation as needing urgent action. Limited information was provided on the kinds of illnesses that can result from exposure. Less than 30% of stories in either media specifically mentioned the common illnesses resulting from air pollution. Very few articles in either media mentioned the population groups most at risk from air pollution, such as children or older people. Vehicles were presented most often as the cause of air pollution in India (in over 50% of articles in both national and international media). Some of the most important sources of air pollution were mentioned less often: 6% of national and 18% of international media articles mentioned unclean sources of household energy; 3% of national and 9% of international media articles mentioned agricultural field burning. Finally, the majority of articles (405; 81%) did not mention any specific

  9. Heavy metal content in flue cured and air cured tobaccos from main production areas in Serbia

    Directory of Open Access Journals (Sweden)

    Radojičić Vesna

    2004-01-01

    Full Text Available The aim of this work was to examine the influence of growing conditions on heavy metal content in virginia (flue cured and burley (air cured tobacco type. Moreover, some of these metals could appear in the tobacco cigarette smoke. This fact may cause negative consequences for cigarette consumers. Examinations were carried out in five various production areas, for each tobacco type, during two years, 1998 and 1999; those were extreme years for production.Considering the results, it can be concluded: The most important factor for heavy metal content in tobacco leaves are weather conditions especially the amount of rainfall, since there is a direct correlation between the rainfall and size of roots, a dominant vegetation organ. It is inevitable that the metals content in flue cured and air cured tobaccos grown at different experimental lots, is still below the legally prescribed values. Tobacco leaves from Šabac production area have a little higher metal content than tobacco grown in other production areas, because a larger amount of copper was found. The metal content in plants can increase because of its absorption from soil, atmosphere, or mineral fertilizers and pesticides, and, what is very important, the content of metals can be high due to the vicinity of large industrial centers.

  10. Study on lycopene and antioxidant contents variations in tomatoes under air-drying process.

    Science.gov (United States)

    Chang, C-H; Liu, Y-C

    2007-11-01

    Effects of factors such as tomato cultivars, drying temperatures (40, 80, and 120 degrees C), and drying time (0 to 240 min) on tomato lycopene and the major antioxidant contents (MACs, herein as the sum of total phenolics and total flavonoids) during an air-drying process were investigated. The results showed that lycopene contents increased under all the drying temperatures during the first 60 min. However, the red tomato cultivars, that is, HR, SN, and TTL, exhibited a significant decrease in lycopene contents under 120 degrees C after drying for 75 min. According to the experimental data, an MAC threshold value of 500 mg/100 g dry matter of tomato is proposed. When the MAC is lower than this value during air-drying, lycopene contents in all tomato cultivars would drop rapidly. In addition, the tomatoes in yellow color group, containing more MACs initially and retaining more MACs under air-drying at 40 to 80 degrees C, are proposed to be the proper tomato cultivars for thermal processing.

  11. Climate and air quality trade-offs in altering ship fuel sulfur content

    Science.gov (United States)

    Partanen, A. I.; Laakso, A.; Schmidt, A.; Kokkola, H.; Kuokkanen, T.; Pietikäinen, J.-P.; Kerminen, V.-M.; Lehtinen, K. E. J.; Laakso, L.; Korhonen, H.

    2013-12-01

    Aerosol particles from shipping emissions both cool the climate and cause adverse health effects. The cooling effect is, however, declining because of shipping emission controls aiming to improve air quality. We used an aerosol-climate model ECHAM-HAMMOZ to test whether by altering ship fuel sulfur content, the present-day aerosol-induced cooling effect from shipping could be preserved, while at the same time reducing premature mortality rates related to shipping emissions. We compared the climate and health effects of a present-day shipping emission scenario (ship fuel sulfur content of 2.7%) with (1) a simulation with strict emission controls in the coastal waters (ship fuel sulfur content of 0.1%) and twofold the present-day fuel sulfur content (i.e. 5.4%) elsewhere; and (2) a scenario with global strict shipping emission controls (ship fuel sulfur content of 0.1% in coastal waters and 0.5% elsewhere) roughly corresponding to international agreements to be enforced by the year 2020. Scenario 1 had a slightly stronger aerosol-induced effective radiative forcing (ERF) from shipping than the present-day scenario (-0.43 W m-2 vs. -0.39 W m-2) while reducing premature mortality from shipping by 69% (globally 34 900 deaths avoided per year). Scenario 2 decreased the ERF to -0.06 W m-2 and annual deaths by 96% (globally 48 200 deaths avoided per year) compared to present-day. Our results show that the cooling effect of present-day emissions could be retained with simultaneous notable improvements in air quality, even though the shipping emissions from the open ocean clearly have a significant effect on continental air quality. However, increasing ship fuel sulfur content in the open ocean would violate existing international treaties, could cause detrimental side-effects, and could be classified as geoengineering.

  12. Kinetic study on non-thermal volumetric plasma decay in the early afterglow of air discharge generated by a short pulse microwave or laser

    Science.gov (United States)

    Yang, Wei; Zhou, Qianhong; Dong, Zhiwei

    2016-08-01

    This paper reports a kinetic study on non-thermal plasma decay in the early afterglow of air discharge generated by short pulse microwave or laser. A global self-consistent model is based on the particle balance of complex plasma chemistry, electron energy equation, and gas thermal balance equation. Electron-ion Coulomb collision is included in the steady state Boltzmann equation solver to accurately describe the electron mobility and other transport coefficients. The model is used to simulate the afterglow of microsecond to nanosecond pulse microwave discharge in N2, O2, and air, as well as femtosecond laser filament discharge in dry and humid air. The simulated results for electron density decay are in quantitative agreement with the available measured ones. The evolution of plasma decay under an external electric field is also investigated, and the effect of gas heating is considered. The underlying mechanism of plasma density decay is unveiled through the above kinetic modeling.

  13. 磷钼酸铵容量法测定磷化液中的磷%Determination of Phosphorus Content in Phosphated Solution by Volumetric Method of Ammonium Phosphomolybdate

    Institute of Scientific and Technical Information of China (English)

    刘志勇; 金欢

    2012-01-01

    A volumetric method of ammonium phosphomolybdate for the determination of phosphorus content ( counted with zinc dihydrogen phosphate) in phosphated solution was reported in this paper. The reliability of this method was proved by comparing the standard phosphorus solution added into the basic solution with the noninterference standard phosphorus solution. The results show that this analytical method has a good accuracy and precision detected by F and t methods. The recovery ratio is 99. 0% ~ 100.0% ,and meets the requirements for analysis.%采用磷钼酸铵容量法测定磷化液中磷(以磷酸二氢锌计)的含量,通过在基础溶液中加入磷标准溶液,与不加入任何干扰物质的磷标准溶液作对比试验,验证分析方法的可靠性.实验结果得出:通过F、t检验法,分析方法的准确度和精密度都较好;回收率在99.0% ~ 100.0%之间,达到分析要求.

  14. Immunochemical approach to indoor aeroallergen quantitation with a new volumetric air sampler: studies with mite, roach, cat, mouse, and guinea pig antigens

    Energy Technology Data Exchange (ETDEWEB)

    Swanson, M.C.; Agarwal, M.K.; Reed, C.E.

    1985-11-01

    We describe a new high-volume air sampler for determining antigen concentrations in homes and illustrate its use for quantitating airborne house dust mite, cat, cockroach, mouse, and guinea pig antigens. The concentration of house dust-mite antigen was similar from houses in Rochester, Minn. and tenement apartments in Harlem, N. Y., but cockroach and mouse urinary proteins were present only in Harlem. The amount of cat or guinea pig antigen varied as expected with the number of pets in the home. In calm air the airborne concentration of mite and cat antigen was similar throughout the house but increased greatly in a bedroom when bedding was changed. In calm air most of the cat and mite antigens were associated with respirable particles less than 5 microns mean aerodynamic mass diameter, but in air sampled after the bedding was changed, more cat antigen was found in particles greater than 5 microns. The apparatus and technique described can provide objective data concerning the magnitude and the relative distribution and duration of suspended particles of defined sizes, which contain allergen activity.

  15. Fatty acid composition and chlorophyll content of epiphytic lichens and a possible relation to their sensitivity to air pollution

    Energy Technology Data Exchange (ETDEWEB)

    Beltman, I.H.; De Kok, L.J.; Juiper, P.J.C.; van Hasselt, P.R.

    1980-01-01

    Fatty acid composition and chlorophyll content of thirteen epiphytic lichen species were determined and related to the air pollution sensitivity of the lichens based upon field observations. A direct relation between the chlorophyll content and, to a lesser extent, the degree of unsaturation of the fatty acids of the lichen species and the sensitivity to air pollution was demonstrated. It is suggested that the sensitivity of lichens to air pollution is related to the degree of dependency of the mycobiont on the phycobiont as far as metabolic energy is concerned; in such a way that the stronger this dependency is, the more sensitive the lichen will be to air pollution.

  16. Measurement of the muon content in air showers at the Pierre Auger Observatory

    Directory of Open Access Journals (Sweden)

    Veberič Darko

    2016-01-01

    Full Text Available The muon content of extensive air showers produced by ultra-high energy cosmic rays is an observable sensitive to the composition of primary particles and to the properties of hadronic interactions governing the evolution of air-shower cascades. We present different methods for estimation of the number of muons at the ground and the muon production depth. These methods use measurements of the longitudinal, lateral, and temporal distribution of particles in air showers recorded by the detectors of the Pierre Auger Observatory. The results, obtained at about 140 TeV center-of-mass energy for proton primaries, are compared to the predictions of LHC-tuned hadronic-interaction models used in simulations with different primary masses. The models exhibit a deficitin the predicted muon content. The combination of these results with other independent mass composition analyses, such as those involving the depth of shower maximum observablemax, provide additional constraints on hadronic-interaction models for energies beyond the reach of the LHC.

  17. Measurement of the muon content in air showers at the Pierre Auger Observatory

    Science.gov (United States)

    Veberič, Darko

    2016-07-01

    The muon content of extensive air showers produced by ultra-high energy cosmic rays is an observable sensitive to the composition of primary particles and to the properties of hadronic interactions governing the evolution of air-shower cascades. We present different methods for estimation of the number of muons at the ground and the muon production depth. These methods use measurements of the longitudinal, lateral, and temporal distribution of particles in air showers recorded by the detectors of the Pierre Auger Observatory. The results, obtained at about 140 TeV center-of-mass energy for proton primaries, are compared to the predictions of LHC-tuned hadronic-interaction models used in simulations with different primary masses. The models exhibit a deficitin the predicted muon content. The combination of these results with other independent mass composition analyses, such as those involving the depth of shower maximum observablemax, provide additional constraints on hadronic-interaction models for energies beyond the reach of the LHC.

  18. 7Be content and its seasonal variation in the ground air around Hangzhou area

    Institute of Scientific and Technical Information of China (English)

    1999-01-01

    Twice investigations around Hangzhou area show that 7Be content average in the ground air is 5.9 mBq.m-3.The content of 7Be is the highest in autumn-winter period reaching about 7.7 mBq.m-3;the next is in spring about 6.2 mBq.m-3;then is in the early summer about 5.7 mBq.m-3,close to the annual average level; and the lowest in a year is in summer-autumn period with a value about 3.8 mBq.m-3. Exhibited is a decreasing trend from autumn-winter period to summer-autumn of the next year,which is negatively correlated with the variation of the seasonal rainfall in Hangzhou area. But this trend is different from that reported by UNSCEAR: it is the highest in spring and the lowest in the late autumn, which is based only on 7Be falling down from the stratosphere. However, the present investigation shows that the seasonal rainfall is the main factor influencing the variation trend of 7Be content in the air.

  19. Volumetric composition in composites and historical data

    DEFF Research Database (Denmark)

    Lilholt, Hans; Madsen, Bo

    2013-01-01

    guidance to the optimal combination of fibre content, matrix content and porosity content, in order to achieve the best obtainable properties. Several composite materials systems have been shown to be handleable with this model. An extensive series of experimental data for the system of cellulose fibres...... and polymer (resin) was produced in 1942 – 1944, and these data have been (re-)analysed by the volumetric composition model, and the property values for density, stiffness and strength have been evaluated. Good agreement has been obtained and some further observations have been extracted from the analysis....

  20. Flexible Volumetric Structure

    Science.gov (United States)

    Cagle, Christopher M. (Inventor); Schlecht, Robin W. (Inventor)

    2014-01-01

    A flexible volumetric structure has a first spring that defines a three-dimensional volume and includes a serpentine structure elongatable and compressible along a length thereof. A second spring is coupled to at least one outboard edge region of the first spring. The second spring is a sheet-like structure capable of elongation along an in-plane dimension thereof. The second spring is oriented such that its in-plane dimension is aligned with the length of the first spring's serpentine structure.

  1. Impact of sulfur content regulations of shipping fuel on coastal air quality

    Science.gov (United States)

    Seyler, André; Wittrock, Folkard; Kattner, Lisa; Mathieu-Üffing, Barbara; Weigelt, Andreas; Peters, Enno; Richter, Andreas; Schmolke, Stefan; Burrows, John P.

    2016-04-01

    Shipping traffic is a sector that faces an enormous growth rate and contributes substantially to the emissions from the transportation sector, but lacks regulations and controls. Shipping is not enclosed in the Kyoto Protocol. However, the International Maritime Organization (IMO) introduced sufhur limits for marine heavy fuels, nitrogen oxide limits for newly-built ship engines and established Emission Control Areas (ECA) in the North and Baltic Sea as well as around North America with the International Convention for the Prevention of Pollution from Ships (MARPOL 73/78 Annex VI). Recently, on the 1st of January 2015, the allowed sulfur content of marine fuels inside Sulfur Emission Control Areas has been significantly decreased from 1.0% to 0.1%. However, measurements of reactive trace gases and the chemical composition of the marine troposphere along shipping routes are sparse and up to now there is no regular monitoring system available. The project MeSmarT (measurements of shipping emissions in the marine troposphere) is a cooperation between the University of Bremen, the German Federal Maritime and Hydrographic Agency (Bundesamt für Seeschifffahrt und Hydrographie, BSH) and the Helmholtz-Zentrum Geesthacht. This study aims to analyse the influence of shipping emissions on the coastal air quality by evaluating ground-based remote sensing measurements using the MAX-DOAS (Multi AXis Differential Optical Absorption Spectroscopy) technique. Measurements of the atmospheric trace gases nitrogen dioxide (NO2) and sulfur dioxide (SO2) have been carried out in the marine troposphere at the MeSmarT measurement sites in Wedel and on Neuwerk and on-board several ship cruises on the North and Baltic Sea. The capability of two-channel MAX-DOAS systems to do simultaneous measurements in the UV and visible spectral range has been used in the so called "onion-peeling" approach to derive spatial distributions of ship emissions and to analyse the movement of the exhausted

  2. Content

    DEFF Research Database (Denmark)

    Keiding, Tina Bering

    Aim, content and methods are fundamental categories of both theoretical and practical general didactics. A quick glance in recent pedagogical literature on higher education, however, reveals a strong preoccupation with methods, i.e. how teaching should be organized socially (Biggs & Tang, 2007......; Race, 2001; Ramsden, 2003). This trend appears closely related to the ‘from-teaching-to-learning’ movement, which has had a strong influence on pedagogy since the early nineties (Keiding, 2007; Terhart, 2003). Another interpretation of the current interest in methodology can be derived from...... for selection of content (Klafki, 1985, 2000; Myhre, 1961; Nielsen, 2006). These attempts all share one feature, which is that criteria for selection of content appear very general and often, more or less explicitly, deal with teaching at the first Bologna-cycle; i.e. schooling at the primary and lower...

  3. What Health-Related Information Flows through You Every Day? A Content Analysis of Microblog Messages on Air Pollution

    Science.gov (United States)

    Yang, Qinghua; Yang, Fan; Zhou, Chun

    2015-01-01

    Purpose: The purpose of this paper is to investigate how the information about haze, a term used in China to describe the air pollution problem, is portrayed on Chinese social media by different types of organizations using the theoretical framework of the health belief model (HBM). Design/methodology/approach: A content analysis was conducted…

  4. What Health-Related Information Flows through You Every Day? A Content Analysis of Microblog Messages on Air Pollution

    Science.gov (United States)

    Yang, Qinghua; Yang, Fan; Zhou, Chun

    2015-01-01

    Purpose: The purpose of this paper is to investigate how the information about haze, a term used in China to describe the air pollution problem, is portrayed on Chinese social media by different types of organizations using the theoretical framework of the health belief model (HBM). Design/methodology/approach: A content analysis was conducted…

  5. Measurements of the muon content of air showers at the Pierre Auger Observatory

    Science.gov (United States)

    Valiño, I.; Pierre Auger Collaboration

    2015-08-01

    The Pierre Auger Observatory offers a unique window to study cosmic rays and particle physics at energies above 3 EeV (corresponding to a centre-of-mass energy of 75 TeV in proton-proton collisions) inaccessible to accelerator experiments. We discuss the different methods of estimating the number of muons in showers recorded at the Pierre Auger Observatory, which is an observable sensitive to primary mass composition and to properties of the hadronic interactions in the shower. The muon content, derived from data with these methods, is presented and compared to predictions from the post-LHC hadronic interaction models for different primary composition. We find that models do not reproduce well the Auger observations, displaying a deficit of muons at the ground. In the light of these results, a better understanding of ultra-high energy extensive air showers and hadronic interactions is crucial to determine the composition of ultra-high energy cosmic rays. We report on the upgrade plans of the Pierre Auger Observatory to achieve this science goal.

  6. Effect of Air Cooling and Vacuum Cooling Storage on the β-Carotene Content and Proximate Analysis (Water Content, pH, Total Protein and Content of Sugar) in Carrot

    Science.gov (United States)

    Kusumaningsih, T.; Martini, T.; Rini, K. S.; Okstafiyanti, L.

    2017-04-01

    The study of air cooling and vacuum cooling storage effect on the β-carotene content and proximate analysis in carrot has been studied. The aim of the research to determine the effective storage in carrot to improve the quality and the shelf life. Parameters measured during the 12 weeks of storage process were β-carotene, pH, water, sugar and protein content. Validation analysis for β-carotene method showed a good linearity (r 2 = 0.997) in a range of 0-8 mg/L and (r 2 = 0.999) in a range of 0-1 mg/L. The precision was exemplified by %RSD of 0.88%-7.48%. Mean recovery was 100.66% during accuracy studied. UV analysis revealed the LOD values were 0.009 mg/L and LOQ values were 0.032 mg/L. The decreased content of β-carotene, water, protein, and pH from carrot during vacuum cooling storage were higher than in the air cooling storage period. The sugar content for air cooling storage increased up to eight weeks and decreased at the end of storage while the vacuum cooling storage decreased from the beginning of the storage period. All the data indicates that the air cooling storage was more effective storage techniques for extending the shelf life of carrot compared to the vacuum cooling storage.

  7. Analysis of chemistry textbook content and national science education standards in terms of air quality-related learning goals

    Science.gov (United States)

    Naughton, Wendy

    In this study's Phase One, representatives of nine municipal agencies involved in air quality education were interviewed and interview transcripts were analyzed for themes related to what citizens need to know or be able to do regarding air quality concerns. Based on these themes, eight air quality Learning Goal Sets were generated and validated via peer and member checks. In Phase Two, six college-level, liberal-arts chemistry textbooks and the National Science Education Standards (NSES) were analyzed for congruence with Phase One learning goals. Major categories of desired citizen understandings highlighted in agency interviews concerned air pollution sources, impact, detection, and transport. Identified cognitive skills focused on information-gathering and -evaluating skills, enabling informed decision-making. A content match was found between textbooks and air quality learning goals, but most textbooks fail to address learning goals that remediate citizen misconceptions and inabilities---particularly those with a "personal experience" focus. A partial match between NSES and air quality learning goals was attributed to differing foci: Researcher-derived learning goals deal specifically with air quality, while NSES focus is on "fundamental science concepts," not "many science topics." Analysis of findings within a situated cognition framework suggests implications for instruction and NSES revision.

  8. Volumetric Combustion Diagnostics

    Science.gov (United States)

    2017-01-03

    example involved a measurement campaign in collaboration with researchers at the Air Force Research Laboratory (Drs. Timothy Ombrello and Campbell ...its impact and promote AFOSR’s vision and mission. In this project, the PI has collaborated with Drs. Campbell Carter and Tim Ombrello to perform...Thermal-Fluid Systems, Heat Transfer Engineering, 37(3-4), 359-368, (2016) [9] Y.W. Lin Ma, Qingchun Lei, Wenjiang Xu, Campbell D. Carter, 3D Flame

  9. PRESERVING VITAMIN C CONTENT IN MELONS DURING LONG-TERM STORAGE BY TREATMNET WITH IONIZED AIR AND SHRINK WRAPPING

    Directory of Open Access Journals (Sweden)

    D. S. Stepanenko

    2014-03-01

    Full Text Available The paper presents and analyzes the results of experimental studies of the dynamics of vitamin C content in fruit of melons. We considered melons of average ripening period from Bereginya and Golden varieties during storage by treatment with ionized air and shrink wrapping. Studies conducted in 2011-2013 at the National Institute of Vine and Wine Magarach (Yalta and Taurian State Agrotechnological University (Melitopol. For the experiment we used a melon fruit of medium ripening, varieties Golden and Bereginya that grow in the steppe zone of southern Ukraine (farm PE Borisov of Yakymovka district, Zaporozhye region. Collection of fruits and their selection for laying deposited were performed in accordance with relevant standards. To determine the mass concentration of ascorbic acid we used iodometric method. Before laying melon fruit for storage of pre-cooled for 25 hours and then spent processing and packaging. In our experiment, we maintained the relative humidity (GDP about of 85% and air temperature of +3 Celcium degrees in the repository. The treatment was carried out using the fruits developed by own patented device for preparing food for storage. Analysis of the experimental data led to the following conclusions: The content of ascorbic acid during the storage of fruits melon was reduced. Storage of fruits, packed (in whole or in part in shrimp and processed by ionized air gave significantly better preservation of vitamin C in the fruit compared to fruit without processing by air and  unpackaged fruits and in control. Storage of fruits, fully packaged and processed by ionized air, gave the best results in the equalization of other research options. The fruits of melon of variety Golden somewhat better retained vitamin C by the end of the storage period, although its original content was lower than in fruit of varieties Bereginya. Keywords: storage of fruits, vitamin C, ionized air, shrink wrap.

  10. Quantitative Techniques in Volumetric Analysis

    Science.gov (United States)

    Zimmerman, John; Jacobsen, Jerrold J.

    1996-12-01

    Quantitative Techniques in Volumetric Analysis is a visual library of techniques used in making volumetric measurements. This 40-minute VHS videotape is designed as a resource for introducing students to proper volumetric methods and procedures. The entire tape, or relevant segments of the tape, can also be used to review procedures used in subsequent experiments that rely on the traditional art of quantitative analysis laboratory practice. The techniques included are: Quantitative transfer of a solid with a weighing spoon Quantitative transfer of a solid with a finger held weighing bottle Quantitative transfer of a solid with a paper strap held bottle Quantitative transfer of a solid with a spatula Examples of common quantitative weighing errors Quantitative transfer of a solid from dish to beaker to volumetric flask Quantitative transfer of a solid from dish to volumetric flask Volumetric transfer pipet A complete acid-base titration Hand technique variations The conventional view of contemporary quantitative chemical measurement tends to focus on instrumental systems, computers, and robotics. In this view, the analyst is relegated to placing standards and samples on a tray. A robotic arm delivers a sample to the analysis center, while a computer controls the analysis conditions and records the results. In spite of this, it is rare to find an analysis process that does not rely on some aspect of more traditional quantitative analysis techniques, such as careful dilution to the mark of a volumetric flask. Figure 2. Transfer of a solid with a spatula. Clearly, errors in a classical step will affect the quality of the final analysis. Because of this, it is still important for students to master the key elements of the traditional art of quantitative chemical analysis laboratory practice. Some aspects of chemical analysis, like careful rinsing to insure quantitative transfer, are often an automated part of an instrumental process that must be understood by the

  11. CONTENTS

    Institute of Scientific and Technical Information of China (English)

    2012-01-01

    The Development and Evolution of the Idea of the Mandate of Heaven in the Zhou Dynasty The changes in the idea of Mandate of Heaven during the Shang and Zhou dynasties are of great significance in the course of the development of traditional Chinese culture. The quickening and awakening of the humanistic spirit was not the entire content of the Zhou idea of Mandate of Heaven. In the process of annihilating the Shang dynasty and setting up their state, the Zhou propagated the idea of the Mandate of Heaven out of practical needs. Their idea of the Mandate of Heaven was not very different from that of the Shang. From the Western Zhou on, the Zhou idea of Mandate of Heaven by no means developed in a linear way along a rational track. The intermingling of rationality and irrationality and of awakening and non-awakening remained the overall state of the Zhou intellectual superstructure after their "spiritual awakening".

  12. Study on Plantago major L. dan Phaseolus vulgaris L. chlorophyll and carotenoid content using as bioincator for air pollution

    Directory of Open Access Journals (Sweden)

    ENDANG ANGGARWULAN

    2007-10-01

    Full Text Available The aims of this research were to study using chlorophyll and carotenoid as bioindicator air quality. This research used completely randomized design 2 x 4 factorial with 5 replicates. The first factor was distance from source of exhaust automobile emissions, consists of 4 levels: 0,50, 100, and 200 m. The second factor was plant spesies, consist 2 level: Plantago major and Phaseolus vulgaris. Data collected were analyzed using Multiple Regression Analysis followed by Duncan Multiple Range Test in 5% confidence level. The result indicated that increasing distance from source exhaust automobile emission, increased growth and chlorophyll content. Chlorophyll content in Phaseolus is more sensitive as bioindicator for air pollution.

  13. Test Facility for Volumetric Absorber

    Energy Technology Data Exchange (ETDEWEB)

    Ebert, M.; Dibowski, G.; Pfander, M.; Sack, J. P.; Schwarzbozl, P.; Ulmer, S.

    2006-07-01

    Long-time testing of volumetric absorber modules is an inevitable measure to gain the experience and reliability required for the commercialization of the open volumetric receiver technology. While solar tower test facilities are necessary for performance measurements of complete volumetric receivers, the long-term stability of individual components can be tested in less expensive test setups. For the qualification of the aging effects of operating cycles on single elements of new absorber materials and designs, a test facility was developed and constructed in the framework of the KOSMOSOL project. In order to provide the concentrated solar radiation level, the absorber test facility is integrated into a parabolic dish system at the Plataforma Solar de Almeria (PSA) in Spain. Several new designs of ceramic absorbers were developed and tested during the last months. (Author)

  14. Contents

    Directory of Open Access Journals (Sweden)

    Editor IJRED

    2012-11-01

    Full Text Available International Journal of Renewable Energy Development www.ijred.com Volume 1             Number 3            October 2012                ISSN 2252- 4940   CONTENTS OF ARTICLES page Design and Economic Analysis of a Photovoltaic System: A Case Study 65-73 C.O.C. Oko , E.O. Diemuodeke, N.F. Omunakwe, and E. Nnamdi     Development of Formaldehyde Adsorption using Modified Activated Carbon – A Review 75-80 W.D.P Rengga , M. Sudibandriyo and M. Nasikin     Process Optimization for Ethyl Ester Production in Fixed Bed Reactor Using Calcium Oxide Impregnated Palm Shell Activated Carbon (CaO/PSAC 81-86 A. Buasri , B. Ksapabutr, M. Panapoy and N. Chaiyut     Wind Resource Assessment in Abadan Airport in Iran 87-97 Mojtaba Nedaei       The Energy Processing by Power Electronics and its Impact on Power Quality 99-105 J. E. Rocha and B. W. D. C. Sanchez       First Aspect of Conventional Power System Assessment for High Wind Power Plants Penetration 107-113 A. Merzic , M. Music, and M. Rascic   Experimental Study on the Production of Karanja Oil Methyl Ester and Its Effect on Diesel Engine 115-122 N. Shrivastava,  , S.N. Varma and M. Pandey  

  15. Effect of consolidation pressure on volumetric composition and stiffness of unidirectional flax fibre composites

    DEFF Research Database (Denmark)

    Aslan, Mustafa; Mehmood, S.; Madsen, Bo

    2013-01-01

    Unidirectional flax/polyethylene terephthalate composites are manufactured by filament winding, followed by compression moulding with low and high consolidation pressure, and with variable flax fibre content. The experimental data of volumetric composition and tensile stiffness are analysed with ...

  16. STUDY ON THE CONTENT OF SEDIMENT PARTICLES IN THE AIR AROUND TG. JIU TOWN

    Directory of Open Access Journals (Sweden)

    Ramona Violeta Cazalbașu

    2016-12-01

    Full Text Available One of the most important problems of the modern era is the air pollution. This phenomenon, highly complex, has become the focus of several international organizations since the consequences of air pollution are felt outside the country borders. By and large wecan speak of a regional pollution, which consists of atmospheric contamination by waste or by products liquids, solids gas, threatening the health of people, plants and animals or which can attack materials, reduce visibility and cause unpleasant odors. On a planetary scale, the elimination or accumulation in the atmosphere of certain products, leads to irreparable consequences on the planet's natural balance: ozone depletion and global warming of the atmosphere. This paper presents the study on the sedimentparticles in the air in Tg-Jiu. Determination of particulate matter from the air was done according to Standard no. 10195 / 75.Air purity.Determination of settled particles. In 2014 no exceeding of the maximum allowable concentration of sediment particles has been found in the four sampling points and in2015, out of a total of 60 measurements in four sampling points only one was above the maximum permissible concentration

  17. Measurement of the Muon content of Extensive Air Showers with the Pierre Auger Observatory

    CERN Document Server

    Espadanal, J

    2015-01-01

    Several methods developed within the Pierre Auger Collaboration for the estimation of the muonic component of the Extensive Air Showers observed in the surface Cherenkov detectors are described. The results derived from the data show a deficit of muons predicted by the current hadronic interactions models at ultra-high energies.

  18. Firn air-content of Larsen C Ice Shelf, Antarctic Peninsula, from seismic velocities, borehole surveys and firn modelling

    Science.gov (United States)

    Kulessa, Bernd; Brisbourne, Alex; Booth, Adam; Kuipers Munneke, Peter; Bevan, Suzanne; Luckman, Adrian; Hubbard, Bryn; Gourmelen, Noel; Palmer, Steve; Holland, Paul; Ashmore, David; Shepherd, Andrew

    2016-04-01

    The rising surface temperature of Antarctic Peninsula ice shelves is strongly implicated in ice shelf disintegration, by exacerbating the compaction of firn layers. Firn compaction is expected to warm the ice column and, given sufficiently wet and compacted layers, to allow meltwater to penetrate into surface crevasses and thus enhance hydrofracture potential. Integrating seismic refraction surveys with borehole neutron and firn core density logging, we reveal vertical and horizontal changes in firn properties across Larsen C Ice Shelf. Patterns of firn air-content derived from seismic surveys are broadly similar to those estimated previously from airborne radar and satellite data. Specifically, these estimates show greater firn compaction in the north and landward inlets compared to the south, although spatial gradients in seismic-derived air-contents are less pronounced than those previously inferred. Firn thickness is less than 10 m in the extreme northwest of Larsen C, in Cabinet Inlet, yet exceeds 40 m in the southeast, suggesting that the inlet is a focus of firn compaction; indeed, buried layers of massive refrozen ice were observed in 200 MHz GPR data in Cabinet and Whirlwind Inlets during a field campaign in the 2014-15 austral summer. Depth profiles of firn density provide a reasonable fit with those derived from closely-located firn cores and neutron probe data. Our model of firn structure is driven by RACMO and includes a 'bucket'-type hydrological implementation, and simulates the depth-density profiles in the inlets well. Discrepancies between measured and modelled depth-density profiles become progressively greater towards the ice-shelf front. RACMO incorrectly simulates the particular leeward (sea-ice-influenced) microclimate of the shallow boundary layer, leading to excess melt and/or lack of snowfall. The spatial sampling density of our seismic observations will be augmented following a further field campaign in the 2016-17 austral summer

  19. Extensive air showers with the small muon content in the region of ultrahigh energies

    Energy Technology Data Exchange (ETDEWEB)

    Mikhailov, A.A.; Efremov, N.N.; Nikiforova, E.S. [Yu.G. Shafer Institute of Cosmophysical Research and Aeronomy, 31 Lenin Ave., 677980 Yakutsk (Russian Federation)

    2008-01-15

    Ultrahigh-energy extensive air showers registered at the Yakutsk EAS array have been considered. The showers without the muon component are detected. Almost one half of them forms the clusters, the arrival directions of which correlate with the nearest pulsars. The classification of showers by muon composition has been carried out and the existence of four classes of showers has been shown. The problem of mass composition and origin of ultrahigh-energy cosmic rays are discussed.

  20. Measuring the muon content of air showers with IceTop

    Directory of Open Access Journals (Sweden)

    Gonzalez Javier G.

    2015-01-01

    Full Text Available IceTop, the surface component of the IceCube detector, has been used to measure the energy spectrum of cosmic ray primaries in the range between 1.58 PeV and 1.26 EeV. It can also be used to study the low energy muons in air showers by looking at large distances (> 300 m from the shower axis. We will show the muon lateral distribution function at large lateral distances as measured with IceTop and discuss the implications of this measurement. We will also discuss the prospects for low energy muon studies with IceTop.

  1. Identifying sensitive windows for prenatal particulate air pollution exposure and mitochondrial DNA content in cord blood.

    Science.gov (United States)

    Rosa, Maria José; Just, Allan C; Guerra, Marco Sánchez; Kloog, Itai; Hsu, Hsiao-Hsien Leon; Brennan, Kasey J; García, Adriana Mercado; Coull, Brent; Wright, Rosalind J; Téllez Rojo, Martha María; Baccarelli, Andrea A; Wright, Robert O

    2017-01-01

    Changes in mitochondrial DNA (mtDNA) can serve as a marker of cumulative oxidative stress (OS) due to the mitochondria's unique genome and relative lack of repair systems. In utero particulate matter ≤2.5μm (PM2.5) exposure can enhance oxidative stress. Our objective was to identify sensitive windows to predict mtDNA damage experienced in the prenatal period due to PM2.5 exposure using mtDNA content measured in cord blood. Women affiliated with the Mexican social security system were recruited during pregnancy in the Programming Research in Obesity, Growth, Environment and Social Stressors (PROGRESS) study. Mothers with cord blood collected at delivery and complete covariate data were included (n=456). Mothers' prenatal daily exposure to PM2.5 was estimated using a satellite-based spatio-temporally resolved prediction model and place of residence during pregnancy. DNA was extracted from umbilical cord leukocytes. Quantitative real-time polymerase chain reaction (qPCR) was used to determine mtDNA content. A distributive lag regression model (DLM) incorporating weekly averages of daily PM2.5 predictions was constructed to plot the association between exposure and OS over the length of pregnancy. In models that included child's sex, mother's age at delivery, prenatal environmental tobacco smoke exposure, birth year, maternal education, and assay batch, we found significant associations between higher PM2.5 exposure during late pregnancy (35-40weeks) and lower mtDNA content in cord blood. Increased PM2.5 during a specific prenatal window in the third trimester was associated with decreased mtDNA content suggesting heightened sensitivity to PM-induced OS during this life stage. Copyright © 2016 Elsevier Ltd. All rights reserved.

  2. Effect of Process Parameters on Warpage and Volumetric Shrinkage of Air Conditioning Fixed Circuit Board%工艺参数对空调电路固定板的翘曲变形和体积收缩的影响研究

    Institute of Scientific and Technical Information of China (English)

    周浩文; 李江平

    2013-01-01

    Taking air conditioning circuit fixed plate as research object, the warpage and volumetric shrinkage were obtained by using Taguchi orthogonal experimental design method with simulation of Moldflow software. Effects of process parameters on warping deformation and volume shrinkage were studied by average analysis and variance analysis, and ideal combination of optimum parameters was obtained.%以空调电路固定板为研究对象,结合Moldflow软件模拟和Taguchi正交试验设计得到对应制品的翘曲变形量和体积收缩率.采用均值分析和方差分析研究各参数对制品翘曲变形量和体积收缩率的影响程度,并获得较为理想的最佳工艺参数组合.

  3. Effect of the moisture content of forced hot air on the postharvest quality and bioactive compounds of mango fruit (Mangifera indica L. cv. Manila).

    Science.gov (United States)

    Ornelas-Paz, José de Jesús; Yahia, Elhadi M

    2014-04-01

    The effectiveness of hot air treatments in controlling decay and insects in mango fruit has been demonstrated and has usually been assessed as a function of the temperature of the heated air and the duration of the treatment. However, the contribution of the moisture content of the heated air has received little attention, especially with regard to fruit quality. In this study, mango fruits (cv. Manila) at mature-green stage were treated with moist (95% relative humidity (RH)) or dry (50% RH) hot forced air (43 °C, at 2.5 m s(-1) for 220 min) and then held at 20 °C for 9 days and evaluated periodically. The heating rate was higher with moist air. Treatments with moist and dry air did not cause injury to the fruit. Treatment with moist air temporarily slowed down color development, softening, weight loss and β-carotene biosynthesis. This slowing down was clearly observed during the first 4-5 days at 20 °C. However, non-heated fruit and fruit heated with dry air showed similar quality at the end of storage. The moisture content of the heating air differentially modulated the postharvest ripening of 'Manila' mangoes. Moist air temporarily slowed down the ripening process of this mango cultivar. © 2013 Society of Chemical Industry.

  4. Volumetric Three-Dimensional Display Systems

    Science.gov (United States)

    Blundell, Barry G.; Schwarz, Adam J.

    2000-03-01

    A comprehensive study of approaches to three-dimensional visualization by volumetric display systems This groundbreaking volume provides an unbiased and in-depth discussion on a broad range of volumetric three-dimensional display systems. It examines the history, development, design, and future of these displays, and considers their potential for application to key areas in which visualization plays a major role. Drawing substantially on material that was previously unpublished or available only in patent form, the authors establish the first comprehensive technical and mathematical formalization of the field, and examine a number of different volumetric architectures. System level design strategies are presented, from which proposals for the next generation of high-definition predictable volumetric systems are developed. To ensure that researchers will benefit from work already completed, they provide: * Descriptions of several recent volumetric display systems prepared from material supplied by the teams that created them * An abstract volumetric display system design paradigm * An historical summary of 90 years of development in volumetric display system technology * An assessment of the strengths and weaknesses of many of the systems proposed to date * A unified presentation of the underlying principles of volumetric display systems * A comprehensive bibliography Beautifully supplemented with 17 color plates that illustrate volumetric images and prototype displays, Volumetric Three-Dimensional Display Systems is an indispensable resource for professionals in imaging systems development, scientific visualization, medical imaging, computer graphics, aerospace, military planning, and CAD/CAE.

  5. [Flora, distribution of vegetation and pollen content of the air: significance for allergics].

    Science.gov (United States)

    Tsukanova, G; Laaidi, M

    2004-09-01

    The wealth of the flora of a given region cannot be seen in its airborne pollen list. Actually, for some plants there is a low probability that their pollens are recorded in the pollen counts (entomogamous plants, in particular). Moreover, the light microscopy reduces the possibilities of determination. In France, The Aerobiological Network of Surveillance (RNSA) retains 92 taxa at different levels (gender, family, group of families), and among them allergenic as well as non allergenic taxa. From the 130 families of the France flora, 63 are taken into account in the pollen studies, 57 taxa being determined at the gender level. The comparison between the surface occupied by the tree species in the French departments of Côte-d'Or and Saône-et-Loire, and the average airborne pollen concentrations showed that usually there is no correspondence between the abundance of a plant and the number of its pollen in the records. So the flora of a region does not give enough information allowing to know the taxonomic composition and the pollen quantities in the air, which is of particular importance for allergic people.

  6. Biodrying of sewage sludge: kinetics of volatile solids degradation under different initial moisture contents and air-flow rates.

    Science.gov (United States)

    Villegas, Manuel; Huiliñir, Cesar

    2014-12-01

    This study focuses on the kinetics of the biodegradation of volatile solids (VS) of sewage sludge for biodrying under different initial moisture contents (Mc) and air-flow rates (AFR). For the study, a 3(2) factorial design, whose factors were AFR (1, 2 or 3L/minkgTS) and initial Mc (59%, 68% and 78% w.b.), was used. Using seven kinetic models and a nonlinear regression method, kinetic parameters were estimated and the models were analyzed with two statistical indicators. Initial Mc of around 68% increases the temperature matrix and VS consumption, with higher moisture removal at lower initial Mc values. Lower AFRs gave higher matrix temperatures and VS consumption, while higher AFRs increased water removal. The kinetic models proposed successfully simulate VS biodegradation, with root mean square error (RMSE) between 0.007929 and 0.02744, and they can be used as a tool for satisfactory prediction of VS in biodrying.

  7. Climatic and insolation control on the high-resolution total air content in the NGRIP ice core

    Science.gov (United States)

    Eicher, Olivier; Baumgartner, Matthias; Schilt, Adrian; Schmitt, Jochen; Schwander, Jakob; Stocker, Thomas F.; Fischer, Hubertus

    2016-10-01

    Because the total air content (TAC) of polar ice is directly affected by the atmospheric pressure and temperature, its record in polar ice cores was initially considered as a proxy for past ice sheet elevation changes. However, the Antarctic ice core TAC record is known to also contain an insolation signature, although the underlying physical mechanisms are still a matter of debate. Here we present a high-resolution TAC record over the whole North Greenland Ice Core Project ice core, covering the last 120 000 years, which independently supports an insolation signature in Greenland. Wavelet analysis reveals a clear precession and obliquity signal similar to previous findings on Antarctic TAC, with a different insolation history. In our high-resolution record we also find a decrease of 4-6 % (4-5 mL kg-1) in TAC as a response to Dansgaard-Oeschger events (DO events). TAC starts to decrease in parallel to increasing Greenland surface temperature and slightly before CH4 reacts to the warming but also shows a two-step decline that lasts for several centuries into the warm interstadial. The TAC response is larger than expected considering only changes in air density by local temperature and atmospheric pressure as a driver, pointing to a transient firnification response caused by the accumulation-induced increase in the load on the firn at bubble close-off, while temperature changes deeper in the firn are still small.

  8. Analysis of the relationship between the volumetric soil moisture content and the NDVI from high resolution multi-spectral images for definition of vineyard management zones to improve irrigation

    Science.gov (United States)

    Martínez-Casasnovas, J. A.; Ramos, M. C.

    2009-04-01

    As suggested by previous research in the field of precision viticulture, intra-field yield variability is dependent on the variation of soil properties, and in particular the soil moisture content. Since the mapping in detail of this soil property for precision viticulture applications is highly costly, the objective of the present research is to analyse its relationship with the normalised difference vegetation index from high resolution satellite images to the use it in the definition of vineyard zonal management. The final aim is to improve irrigation in commercial vineyard blocks for better management of inputs and to deliver a more homogeneous fruit to the winery. The study was carried out in a vineyard block located in Raimat (NE Spain, Costers del Segre Designation of Origin). This is a semi-arid area with continental Mediterranean climate and a total annual precipitation between 300-400 mm. The vineyard block (4.5 ha) is planted with Syrah vines in a 3x2 m pattern. The vines are irrigated by means of drips under a partial root drying schedule. Initially, the irrigation sectors had a quadrangular distribution, with a size of about 1 ha each. Yield is highly variable within the block, presenting a coefficient of variation of 24.9%. For the measurement of the soil moisture content a regular sampling grid of 30 x 40 m was defined. This represents a sample density of 8 samples ha-1. At the nodes of the grid, TDR (Time Domain Reflectometer) probe tubes were permanently installed up to the 80 cm or up to reaching a contrasting layer. Multi-temporal measures were taken at different depths (each 20 cm) between November 2006 and December 2007. For each date, a map of the variability of the profile soil moisture content was interpolated by means of geostatistical analysis: from the measured values at the grid points the experimental variograms were computed and modelled and global block kriging (10 m squared blocks) undertaken with a grid spacing of 3 m x 3 m. On the

  9. Estimation of the near surface soil water content during evaporation using air-launched ground-penetrating radar

    KAUST Repository

    Moghadas, Davood

    2014-01-01

    Evaporation is an important process in the global water cycle and its variation affects the near sur-face soil water content, which is crucial for surface hydrology and climate modelling. Soil evaporation rate is often characterized by two distinct phases, namely, the energy limited phase (stage-I) and the soil hydraulic limited period (stage-II). In this paper, a laboratory experiment was conducted using a sand box filled with fine sand, which was subject to evaporation for a period of twenty three days. The setup was equipped with a weighting system to record automatically the weight of the sand box with a constant time-step. Furthermore, time-lapse air-launched ground penetrating radar (GPR) measurements were performed to monitor the evaporation process. The GPR model involves a full-waveform frequency-domain solution of Maxwell\\'s equations for wave propagation in three-dimensional multilayered media. The accuracy of the full-waveform GPR forward modelling with respect to three different petrophysical models was investigated. Moreover, full-waveform inversion of the GPR data was used to estimate the quantitative information, such as near surface soil water content. The two stages of evaporation can be clearly observed in the radargram, which indicates qualitatively that enough information is contained in the GPR data. The full-waveform GPR inversion allows for accurate estimation of the near surface soil water content during extended evaporation phases, when a wide frequency range of GPR (0.8-5.0 GHz) is taken into account. In addition, the results indicate that the CRIM model may constitute a relevant alternative in solving the frequency-dependency issue for full waveform GPR modelling.

  10. Change in color and other fruit quality characteristics of tomato cultivars after hot-air drying at low final-moisture content.

    Science.gov (United States)

    Ashebir, Dereje; Jezik, Karoline; Weingartemann, Herbert; Gretzmacher, Ralph

    2009-01-01

    The present study aimed to evaluate the drying quality of three tomato cultivars (Amoroso, Berlinto and Messina) at low final-moisture content. Tomatoes were cut into slices and hot-air-dried from 92% (wet basis) to 12% final moisture content at 55 degrees C, 65 degrees C and 75 degrees C at 1.5 m/sec air flow. Color, total soluble solids (TSS), titratable acidity (TA) and ascorbic acid (AA) content were measured in both fresh and dried tomatoes. Brightness of the dried tomato slices was significantly decreased, while intensity of the red and yellow colors and brightness of the red color (a*/b*) increased. Low overall color change (DeltaE) was obtained at the lowest drying temperature (55 degrees C). Messina and Amoroso showed a higher a* value and lower DeltaE, respectively. The TSS content was increased, while the TA and AA contents were decreased through drying. This study shows that it is possible to hot-air dry tomato slices to a final moisture content of 12% maintaining quality that is comparable with studies where the final-moisture content was higher (15% or more).

  11. A reduced volumetric expansion factor plot

    Science.gov (United States)

    Hendricks, R. C.

    1979-01-01

    A reduced volumetric expansion factor plot has been constructed for simple fluids which is suitable for engineering computations in heat transfer. Volumetric expansion factors have been found useful in correlating heat transfer data over a wide range of operating conditions including liquids, gases and the near critical region.

  12. Desiccation-Induced Volumetric Shrinkage of Compacted Metakaolin-Treated Black Cotton Soil for a Hydraulic Barriers System

    Science.gov (United States)

    Moses, George; Peter, Oriola F. O.; Osinubi, Kolawole J.

    2016-03-01

    Black cotton soil treated with up to 24% metakaolin (MCL) content was prepared by molding water contents of -2, 0, 2, 4 and 6% of optimum moisture content (OMC) and compacted with British Standard Light (BSL) and West African Standard (WAS) or `Intermediate' energies. The specimens were extruded from the compaction molds and allowed to air dry in a laboratory in order to assess the effect of desiccation-induced shrinkage on the compacted mix for use as a hydraulic barrier in a waste containment application. The results recorded show that the volumetric shrinkage strain (VSS) values were large within the first 10 days of drying; the VSS values increased with a higher molding of the water content, relative to the OMC. The VSS generally increased with a higher initial degree of saturation for the two compactive efforts, irrespective of the level of MCL treatment. Generally, the VSS decreased with an increasing MCL content. Only specimens treated with a minimum 20% MCL content and compacted with the WAS energy satisfied the regulatory maximum VSS of 4% for use as a hydraulic barrier.

  13. Desiccation-Induced Volumetric Shrinkage of Compacted Metakaolin-Treated Black Cotton Soil for a Hydraulic Barriers System

    Directory of Open Access Journals (Sweden)

    Moses George

    2016-03-01

    Full Text Available Black cotton soil treated with up to 24% metakaolin (MCL content was prepared by molding water contents of −2, 0, 2, 4 and 6% of optimum moisture content (OMC and compacted with British Standard Light (BSL and West African Standard (WAS or ‘Intermediate’ energies. The specimens were extruded from the compaction molds and allowed to air dry in a laboratory in order to assess the effect of desiccation-induced shrinkage on the compacted mix for use as a hydraulic barrier in a waste containment application. The results recorded show that the volumetric shrinkage strain (VSS values were large within the first 10 days of drying; the VSS values increased with a higher molding of the water content, relative to the OMC. The VSS generally increased with a higher initial degree of saturation for the two compactive efforts, irrespective of the level of MCL treatment. Generally, the VSS decreased with an increasing MCL content. Only specimens treated with a minimum 20% MCL content and compacted with the WAS energy satisfied the regulatory maximum VSS of 4% for use as a hydraulic barrier.

  14. [Seasonal variation in the content of spores of the genus Alternaria Nees ex Fr. in the air of the city of Córdoba (Spain)].

    Science.gov (United States)

    Nogales Moncada, M T; Domínguez Vilches, E; Galán Soldevilla, C; Ruiz de Clavijo Jiménez, E

    1986-01-01

    The spore concentrations of Alternaria, a genera of microfungi widely considered as allergenic by different authors (Caplin & Haynes, Gravesen, Gregory, Larsen, Petersen & Sandberg), have been investigated in the atmosphere of Córdoba (Spain) during the period of April, 1983 to March, 1985 by means of the volumetric (Andersen sampler) and gravimetric (Durham based) methods, taking samples three times a day in culture media (Agar-Malt extract 2%) and incubating them for 5-7 days. The objectives of the work have been the establishment of seasonal variation patterns, as well as the possible correlations with the climatological factors. The results show that the different species of Alternaria detected are among the most important components in the aeromycoflora of the town, only exceeded by Cladosporium ssp., yeasts and Mycelia sterilia. In fact we found 3,283 colonies of Alternaria through the gravimetric method and 572 through the volumetric method, representing a 4.28% and 0.59% respectively of the total developed colonies during the sample period. The seasonal variations in air spore concentrations of Alternaria have also been studied monthly following the methods indicated above. It was found that January is always the month with less incidence of spores, with some days free of spores. May was the month with a maximum spores incidence during the first year of study, while this was delayed until june in the second year. This delay was probably due to the prolonged rainy season during the last spring. By establishing positive groups, A. alternata was found to be the most frequent species, with seven months during the period 1984-1985 exceeding the figure of 150 colonies per month.(ABSTRACT TRUNCATED AT 250 WORDS)

  15. Coal char oxidation kinetics in air medium

    Directory of Open Access Journals (Sweden)

    Korotkikh Alexander G.

    2017-01-01

    Full Text Available Study of oxidation kinetics for three types of coal char with different carbon content in air is presented. The coal char powders of anthracite, bituminous T-grade coal and 2B-grade lignite with particle size less than 80 μm were tested. The coal char oxidation was researched by isothermal method via simultaneous TG-DSC analyzer Netzsch STA 449 Jupiter F3 in the temperature range of 1000–1200 °C. Measurements were carried out at ambient pressure. Volumetric flow rate of oxidizing medium into analyser chamber was 250 ml/min. Flow consisted of air and argon with volumetric ratio 24/1. Carbon average rate of oxidation reaction at each temperature were defined based on experimental results. Kinetic constants (the frequency factor and activation energy were defined for Arrhenius equation modified with three submodels: volumetric model, shrinking core model and random pore model. The activation energy values for anthracite are 1,6-1,7 times higher than for chars of bituminous coal and lignite.

  16. Effect of Initial Moisture Content on the in-Vessel Composting Under Air Pressure of Organic Fraction of MunicipalSolid Waste in Morocco

    Directory of Open Access Journals (Sweden)

    Abdelhadi Makan

    2013-01-01

    Full Text Available This study aimed to evaluate the effect of initial moisture content on the in-vessel composting under air pressure of organic fraction of municipal solid waste in Morocco in terms of internal temperature, produced gases quantity, organic matter conversion rate, and the quality of the final composts.For this purpose, in-vessel bioreactor was designed and used to evaluate both appropriate initial air pressure and appropriate initial moisture content for the composting process. Moreover, 5 experiments were carried out within initial moisture content of 55%, 65%, 70%, 75% and 85%. The initial air pressure and the initial moisture content of the mixture showed a significant effect on the aerobic composting. The experimental results demonstrated that for composting organic waste, relatively high moisture contents are better at achieving higher temperatures and retaining them for longer times.This study suggested that an initial moisture content of around 75%, under 0.6 bar, can be considered as being suitable for efficient composting of organic fraction of municipal solid waste. These last conditions, allowed maximum value of temperature and final composting product with good physicochemical properties as well as higher organic matter degradation and higher gas production. Moreover, final compost obtained showed good maturity levels and can be used for agricultural applications.

  17. Exploring Content Management Issues in Air Force On-Line Communities of Practice: A Multiple Case Study Approach

    Science.gov (United States)

    2006-05-31

    CoPs will come with an automated content management system . The default setting on the content management system for content review on the... content management system , the APQC found “conducting a content audit was strongly correlated with every category of improved performance in content...the CoPs. Finally, a researcher could perform a more in-depth study to determine if a commercially available content management system would be

  18. On the Uncertain Future of the Volumetric 3D Display Paradigm

    Science.gov (United States)

    Blundell, Barry G.

    2017-06-01

    Volumetric displays permit electronically processed images to be depicted within a transparent physical volume and enable a range of cues to depth to be inherently associated with image content. Further, images can be viewed directly by multiple simultaneous observers who are able to change vantage positions in a natural way. On the basis of research to date, we assume that the technologies needed to implement useful volumetric displays able to support translucent image formation are available. Consequently, in this paper we review aspects of the volumetric paradigm and identify important issues which have, to date, precluded their successful commercialization. Potentially advantageous characteristics are outlined and demonstrate that significant research is still needed in order to overcome barriers which continue to hamper the effective exploitation of this display modality. Given the recent resurgence of interest in developing commercially viable general purpose volumetric systems, this discussion is of particular relevance.

  19. The effects of dimensional mould sizes on volumetric shrinkage strain of lateritic soil

    Directory of Open Access Journals (Sweden)

    John Engbonye SANI

    2016-07-01

    Full Text Available Dimensional influences of specimen size on the volumetric shrinkage strain values of a lateritic soil for waste containment system have not been researched upon. Therefore, this paper presents the result of a laboratory study on the volumetric shrinkage strain (VSS of lateritic soil at three different dimensional sizes of mould (split former mould, proctor mould and California bearing ratio mould at three energy levels; British standard light (BSL, West African standard (WAS and British standard heavy (BSH respectively. Compactions were done at different molding water content of -2% to +6% optimum moisture content (OMC. At -2% to +2% molding water content for the split former mould the volumetric shrinkage strain met the requirement of not more than 4% while at +4% and +6% only the WAS and BSH met the requirement. The proctor mould and the CBR mould on the other hand gave a lower value of volumetric shrinkage strain in all compactive effort and the values are lower than the 4% safe VSS suggested by Tay et al., (2001. Based on the VSS values obtained if the CBR mould can be used to model site condition it is recommended for use to simulate site condition for Volumetric shrinkage strain for all molding water content and compactive effort.

  20. EFFECT OF GASOLINE - ETHANOL BLENDS ON PERFORMANCE AND EMISSION CHARACTERISTICS OF A SINGLE CYLINDER AIR COOLED MOTOR BIKE SI ENGINE

    Directory of Open Access Journals (Sweden)

    A. SAMUEL RAJA

    2015-12-01

    Full Text Available This paper investigates the effect of using gasoline-ethanol (GE blends on performance and exhaust emission of a four stroke 150 cc single cylinder air cooled spark ignition (SI engine, without any modifications. Experiments were conducted at part load and different engine speeds ranging from 3000 to 5000 rpm, without and with catalytic converter. Ethanol content was varied from 5 percentage to 20 percentage by volume and four different blends (E5, E10, E15 and E20 were tested. Fuel consumption, engine speed, air fuel ratio, exhaust gas temperature and exhaust emissions were measured during each experiment. Brake thermal efficiency (ηb,th, volumetric efficiency (ηvol, brake specific fuel consumption (BSFC and excess air factor were calculated for each test run. Brake specific fuel consumption, volumetric efficiency and excess air factor increased with ethanol percentage in the blend. Carbon monoxide (CO, hydrocarbon (HC and oxides of nitrogen (NOx emissions decreased with blends.

  1. Surfactant enhanced volumetric sweep efficiency

    Energy Technology Data Exchange (ETDEWEB)

    Harwell, J.H.; Scamehorn, J.F.

    1989-10-01

    Surfactant-enhanced waterflooding is a novel EOR method aimed to improve the volumetric sweep efficiencies in reservoirs. The technique depends upon the ability to induce phase changes in surfactant solutions by mixing with surfactants of opposite charge or with salts of appropriate type. One surfactant or salt solution is injected into the reservoir. It is followed later by injection of another surfactant or salt solution. The sequence of injections is arranged so that the two solutions do not mix until they are into the permeable regions well away from the well bore. When they mix at this point, by design they form a precipitate or gel-like coacervate phase, plugging this permeable region, forcing flow through less permeable regions of the reservoir, improving sweep efficiency. The selectivity of the plugging process is demonstrated by achieving permeability reductions in the high permeable regions of Berea sandstone cores. Strategies were set to obtain a better control over the plug placement and the stability of plugs. A numerical simulator has been developed to investigate the potential increases in oil production of model systems. Furthermore, the hardness tolerance of anionic surfactant solutions is shown to be enhanced by addition of monovalent electrolyte or nonionic surfactants. 34 refs., 32 figs., 8 tabs.

  2. Laser Based 3D Volumetric Display System

    Science.gov (United States)

    1993-03-01

    Literature, Costa Mesa, CA July 1983. 3. "A Real Time Autostereoscopic Multiplanar 3D Display System", Rodney Don Williams, Felix Garcia, Jr., Texas...8217 .- NUMBERS LASER BASED 3D VOLUMETRIC DISPLAY SYSTEM PR: CD13 0. AUTHOR(S) PE: N/AWIU: DN303151 P. Soltan, J. Trias, W. Robinson, W. Dahlke 7...laser generated 3D volumetric images on a rotating double helix, (where the 3D displays are computer controlled for group viewing with the naked eye

  3. Effect of ultrasound and blanching pretreatments on polyacetylene and carotenoid content of hot air and freeze dried carrot discs.

    Science.gov (United States)

    Rawson, A; Tiwari, B K; Tuohy, M G; O'Donnell, C P; Brunton, N

    2011-09-01

    The effect of ultrasound and blanching pretreatments on polyacetylene (falcarinol, falcarindiol and falcarindiol-3-acetate) and carotenoid compounds of hot air and freeze dried carrot discs was investigated. Ultrasound pretreatment followed by hot air drying (UPHD) at the highest amplitude and treatment time investigated resulted in higher retention of polyacetylenes and carotenoids in dried carrot discs than blanching followed by hot air drying. Freeze dried samples had a higher retention of polyacetylene and carotenoid compounds compared to hot air dried samples. Color parameters were strongly correlated with carotenoids (p<0.05). This study shows that ultrasound pretreatment is a potential alternative to conventional blanching treatment in the drying of carrots.

  4. Effect of air flow rate on the polyphenols content and antioxidant capacity of convective dried cactus pear cladodes (Opuntia ficus indica).

    Science.gov (United States)

    Gallegos-Infante, José-Alberto; Rocha-Guzman, Nuria-Elizabeth; González-Laredo, Ruben-Francisco; Reynoso-Camacho, Rosalia; Medina-Torres, Luis; Cervantes-Cardozo, Veronica

    2009-01-01

    The interest in nopal has encouraged the use of dehydration; there are few studies about the effect of process parameters on the nopal polyphenol content and antioxidant activity. The objective of the present work was to evaluate the effect of air-drying flow rates on the amount and antioxidant capacity of extracts of Opuntia ficus indica cladodes. Nopal was dried at 45 degrees C and air flow rates of 3 and 5 m/sec. Samples were analyzed for moisture, total polyphenol, flavonoid, and flavonol contents, chain-breaking activity, inhibition of low-density lipoprotein and deoxyribose oxidation. Nopal drying at an air flow rate of 3 m/sec showed higher values of phenols, flavonoids and flavonols. The best value of low-density lipoprotein inhibition and deoxyribose was found at 1,000 microg/ml. The air flow rate affected the amount of polyphenols and the OH( . ) radical scavenging, but did not modify the chain-breaking activity and the low-density lipoprotein inhibition activity.

  5. Nonequilibrium volumetric response of shocked polymers

    Energy Technology Data Exchange (ETDEWEB)

    Clements, B E [Los Alamos National Laboratory

    2009-01-01

    Polymers are well known for their non-equilibrium deviatoric behavior. However, investigations involving both high rate shock experiments and equilibrium measured thermodynamic quantities remind us that the volumetric behavior also exhibits a non-equilibrium response. Experiments supporting the notion of a non-equilibrium volumetric behavior will be summarized. Following that discussion, a continuum-level theory is proposed that will account for both the equilibrium and non-equilibrium response. Upon finding agreement with experiment, the theory is used to study the relaxation of a shocked polymer back towards its shocked equilibrium state.

  6. Transient Simulation Of A Solar-Hybrid Tower Power Plant With Open Volumetric Receiver At The Location Barstow

    OpenAIRE

    2013-01-01

    In this work the transient simulations of four hybrid solar tower power plant concepts with open-volumetric receiver technology for a location in Barstow-Daggett, USA, are presented. The open-volumetric receiver uses ambient air as heat transfer fluid and the hybridization is realized with a gas turbine. The Rankine cycle is heated by solar-heated air and/or by the gas turbine’s flue gases. The plant can be operated in solar-only, hybrid parallel or combined cycle-only mode as well a...

  7. Process conditions and volumetric composition in composites

    DEFF Research Database (Denmark)

    Madsen, Bo

    2013-01-01

    The obtainable volumetric composition in composites is linked to the gravimetric composition, and it is influenced by the conditions of the manufacturing process. A model for the volumetric composition is presented, where the volume fractions of fibers, matrix and porosity are calculated as a fun...... is increased. Altogether, the model is demonstrated to be a valuable tool for a quantitative analysis of the effect of process conditions. Based on the presented findings and considerations, examples of future work are mentioned for the further improvement of the model.......The obtainable volumetric composition in composites is linked to the gravimetric composition, and it is influenced by the conditions of the manufacturing process. A model for the volumetric composition is presented, where the volume fractions of fibers, matrix and porosity are calculated...... as a function of the fiber weight fraction, and where parameters are included for the composite microstructure, and the fiber assembly compaction behavior. Based on experimental data of composites manufactured with different process conditions, together with model predictions, different types of process related...

  8. Indexing Volumetric Shapes with Matching and Packing.

    Science.gov (United States)

    Koes, David Ryan; Camacho, Carlos J

    2015-04-01

    We describe a novel algorithm for bulk-loading an index with high-dimensional data and apply it to the problem of volumetric shape matching. Our matching and packing algorithm is a general approach for packing data according to a similarity metric. First an approximate k-nearest neighbor graph is constructed using vantage-point initialization, an improvement to previous work that decreases construction time while improving the quality of approximation. Then graph matching is iteratively performed to pack related items closely together. The end result is a dense index with good performance. We define a new query specification for shape matching that uses minimum and maximum shape constraints to explicitly specify the spatial requirements of the desired shape. This specification provides a natural language for performing volumetric shape matching and is readily supported by the geometry-based similarity search (GSS) tree, an indexing structure that maintains explicit representations of volumetric shape. We describe our implementation of a GSS tree for volumetric shape matching and provide a comprehensive evaluation of parameter sensitivity, performance, and scalability. Compared to previous bulk-loading algorithms, we find that matching and packing can construct a GSS-tree index in the same amount of time that is denser, flatter, and better performing, with an observed average performance improvement of 2X.

  9. Dating the 800 ka - long EPICA DC ice core by tuning the air content and δO2/N2 records on local summer insolation.

    Science.gov (United States)

    Raynaud, D.; Lipenkov, V.; Loutre, M.-F.; Landais, A.; Capron, E.

    2012-04-01

    A new method of dating the long glacial-interglacial ice core records has emerged during the last 10 years. It is based on properties measured on the air extracted from the ice that are used as proxies of local summer insolation. This dating method is referred to as "local orbital tuning dating". It's an almost absolute dating, providing we better understand the link between the influence of the local summer insolation on the snow grains at the surface and the measured properties in the ice, namely the content and the δO2/N2 ratio of the air enclosed in the ice. Changes in these two properties have already shown convincing correlations with orbitally forced local summer insolation on several Antarctic and Greenland long ice core records. Moreover, both δO2/N2 and air content have recently been measured for the first time on the same ice core (Vostok). The same methods of spectral analysis were applied on these records. The two experimentally independent local insolation proxies lead to orbital timescales that agree well together (within less than 1ka on average). We present here new air content (V) data obtained along the Antarctic EPICA DC ice cores. These data extent the existing record, which covers the last 430,000 years, to about 800,000 years, i.e. they add four glacial-interglacial cycles. The new record has a time resolution of 2,000 years on average. The spectral properties of the new 430 - 800 kyr V record are primarily obtained by continuous wavelet transform (CWT) analysis. It confirms and refines the results from the Blackman-Tukey (BT) and Multi-Taper Method (MTM analysis). The spectral signature of V is compared to its specific Integrated Summer Insolation (ISI) target and the time delay between the V signal and its ISI target is used to propose a V chronology for the oldest part of the record (800-430 kyr BP). The spectral signatures of V and the insolation targets will be compared between the 800 -430 ka BP period (this work) and the 430 - 0 ka

  10. Plant pollen content in the air of Lublin (central-eastern Poland and risk of pollen allergy

    Directory of Open Access Journals (Sweden)

    Krystyna Piotrowska-Weryszko

    2014-11-01

    Full Text Available Pollen monitoring was carried out in Lublin in 2001–2012 by the volumetric method using a Hirst-type spore trap (Lanzoni VPPS 2000. Daily pollen concentrations considerably differed in the particular years. The pollen counts with the biggest variability were observed in the first half of a year when woody plants flowering. The highest annual pollen index were noted for the following taxa: [i]Betula, Urtica,[/i] Pinaceae, Poaceae and [i]Alnus[/i]. [i]Betula[/i] annual total showed the greatest diversity in the study years. The number of days on which the pollen concentration exceeded the threshold values, thereby inducing allergies, was determined for the taxa producing the most allergenic pollen. The above-mentioned taxa primarily included the following: Poaceae, in the case of which the highest number of days with the risk of occurrence of pollen allergy was found (35, [i]Betula[/i] (18, and [i]Artemisia[/i] (10. The following taxa:[i] Alnus[/i] (14 days, [i]Populus[/i] (11 days, [i]Fraxinus[/i] (10 days, and [i]Quercus[/i] (8 days, were also characterized by a large number of days on which their pollen concentrations exceeded the threshold values. The occurrence of periods of high concentration of particular pollen types were also noted. Risk of pollen allergy appeared the earliest at the beginning of February during [i]Alnus [/i]and [i]Corylus[/i] blooming. High concentrations of other woody plants were recorded from the last ten days of March to about 20 May, and of herbaceous plants from the first/last half of May – beginning of October.

  11. Sampling and TDR probe insertion in the determination of the volumetric soil water content Procedimentos de amostragem e do modo de inserção no solo de sondas TDR na determinação da umidade volumétrica do solo

    Directory of Open Access Journals (Sweden)

    W. G. Teixeira

    2003-08-01

    Full Text Available Volumetric soil water content (theta can be evaluated in the field by direct or indirect methods. Among the direct, the gravimetric method is regarded as highly reliable and thus often preferred. Its main disadvantages are that sampling and laboratory procedures are labor intensive, and that the method is destructive, which makes resampling of a same point impossible. Recently, the time domain reflectometry (TDR technique has become a widely used indirect, non-destructive method to evaluate theta. In this study, evaluations of the apparent dielectric number of soils (epsilon and samplings for the gravimetrical determination of the volumetric soil water content (thetaGrav were carried out at four sites of a Xanthic Ferralsol in Manaus - Brazil. With the obtained epsilon values, theta was estimated using empirical equations (thetaTDR, and compared with thetaGrav derived from disturbed and undisturbed samples. The main objective of this study was the comparison of thetaTDR estimates of horizontally as well as vertically inserted probes with the thetaGrav values determined by disturbed and undisturbed samples. Results showed that thetaTDR estimates of vertically inserted probes and the average of horizontally measured layers were only slightly and insignificantly different. However, significant differences were found between the thetaTDR estimates of different equations and between disturbed and undisturbed samples in the thetaGrav determinations. The use of the theoretical Knight et al. model, which permits an evaluation of the soil volume assessed by TDR probes, is also discussed. It was concluded that the TDR technique, when properly calibrated, permits in situ, nondestructive measurements of q in Xanthic Ferralsols of similar accuracy as the gravimetric method.A umidade volumétrica do solo (teta no campo pode ser avaliada por métodos diretos e indiretos. Dentre os métodos diretos, o gravimétrico é considerado altamente confiável e, conseq

  12. Direct Measuring Methods of Water Vapor Content and Air Velocity at High Temperature using ZrO2-MgO Gas Chemisorption Type Ceramic Body

    Science.gov (United States)

    Nomura, Tomohiro; Nishimura, Nobuya; Shiba, Tooru; Hyodo, Tsutomu

    The control of humidity or air velocity as well as temperature is imperative for industrial process equipment such as air conditioners, dryers. At present, much about humidity sensors has been reported, and recently, ceramic sensors have been used with improved results. However, the effective operating temperature of these sensors for a direct measurement of the humidity is about 423 K at the highest. From the various ceramic sensors so far investigated, the authors selected composite ceramics ZrO2-MgO with porous structure and n-type semiconductor for humidity sensing at high temperature. This is because, when the working temperature of the ceramic sensor is between 673 and 973K, the sensor detects the presence of water vapor and gas velocity by the variations in the electronic condition caused by the reversible of the water vapor. From the test, the sensor that use a single sensing ceramic element can detect directly both the water vapor content in a mixed gas of air and superheated vapor in the temperature range 373-773 K and the air velocity(O.5-4m/s) in the range 373-573K.

  13. Assessment of suspended particulate matters and their heavy metal content in the ambient air of Mobarakeh city, Isfahan, Iran

    Directory of Open Access Journals (Sweden)

    Avazali Saririan Mobarakeh

    2014-01-01

    Conclusion: This study showed that ambient air of Mobarakeh city is polluted by TSP. The high concentration of Fe and Ni in this area may be attributed to the nearby industrial emissions. Therefore, in industrial areas, efforts should be taken to control the atmospheric pollution in order to protect humans from hazardous health effects of these potentially toxic pollutants.

  14. Measurement of muon content in inclined air showers above 4 x 10{sup 18} eV

    Energy Technology Data Exchange (ETDEWEB)

    Dembinski, Hans; Roth, Markus [IKP, Karlsruhe Institut of Technology (KIT) (Germany); Collaboration: Pierre-Auger-Collaboration

    2013-07-01

    The Pierre Auger Observatory in Malarguee, Argentina, is sensitive to air showers up to almost horizontal angles of incidence. Air showers with zenith angles between 60 and 80 degrees are suited to measure the muon component of the shower with the Auger Surface Detector since the primary electromagnetic component gets absorbed in the atmosphere before the shower reaches ground. Some of those events are also observed by the Fluorescence Detector which allows us to determine the total energy of the shower independent of the Surface Detector. Based on these hybrids events the size of muon component for a given cosmic ray energy is determined, which can then be compared to model predictions. We present an update of this analysis.

  15. DYNAMICS OF HUMUS CONTENT AND AIR-WATER SOIL PROPERTIES IN INTENSIVE VEGETABLE AND FLOWER GLASSHOUSE PRODUCTION

    Directory of Open Access Journals (Sweden)

    Nada Parađiković

    2007-12-01

    Full Text Available The investigation was conducted in Magadenovac glasshouses, eastern Croatia during seventeen years (1985. - 2002.. In that period, the glasshouse production of vegetables and flowers was intensive during the whole year. The trial was set up on 500 m2. Because of often crop rotation during the same year, soil tillage must be done fast and soil must be homogenized till depth of about 40 cm. Often in practice it is not possible to plough because of numerous reasons and then main mechanization is roto-digging machine. The aim of this investigation was to determine the consequences of long-term application of the special roto-digging machine and dynamics of organic matter and humus content during 17 years. For this purpose, multiple chemical and physical analyses were done. It was determined that, by intensive production during 17 years, organic matter content in soil surface layer significantly decreased (1995 year - 8.60% and 2002 year - 5.00%. In subsurface layer (35-50 cm organic matter content decreased by about 50%. At the same time, by decreasing organic matter content soil became more acid, because pH value measured in 1M KCl after 17 years was by 1.4 units lower in the surface layer, and by about 0.5 units lower in subsurface layer. Finally, soil became acid (pHKCl = 4.8. Decreasing in organic matter and humus content led to soil compaction, decreased soil porosity and degradation of other physical and chemical properties. It can be concluded, that it is necessary to import complete agricultural operations relative to soil tillage for soil preserving.

  16. Combined surface and volumetric occlusion shading

    KAUST Repository

    Schott, Matthias O.

    2012-02-01

    In this paper, a method for interactive direct volume rendering is proposed that computes ambient occlusion effects for visualizations that combine both volumetric and geometric primitives, specifically tube shaped geometric objects representing streamlines, magnetic field lines or DTI fiber tracts. The proposed algorithm extends the recently proposed Directional Occlusion Shading model to allow the rendering of those geometric shapes in combination with a context providing 3D volume, considering mutual occlusion between structures represented by a volume or geometry. © 2012 IEEE.

  17. MR volumetric assessment of endolymphatic hydrops

    Energy Technology Data Exchange (ETDEWEB)

    Guerkov, R.; Berman, A.; Jerin, C.; Krause, E. [University of Munich, Department of Otorhinolaryngology Head and Neck Surgery, Grosshadern Medical Centre, Munich (Germany); University of Munich, German Centre for Vertigo and Balance Disorders, Grosshadern Medical Centre, Marchioninistr. 15, 81377, Munich (Germany); Dietrich, O.; Flatz, W.; Ertl-Wagner, B. [University of Munich, Institute of Clinical Radiology, Grosshadern Medical Centre, Munich (Germany); Keeser, D. [University of Munich, Institute of Clinical Radiology, Grosshadern Medical Centre, Munich (Germany); University of Munich, German Centre for Vertigo and Balance Disorders, Grosshadern Medical Centre, Marchioninistr. 15, 81377, Munich (Germany); University of Munich, Department of Psychiatry and Psychotherapy, Innenstadtkliniken Medical Centre, Munich (Germany)

    2014-10-16

    We aimed to volumetrically quantify endolymph and perilymph spaces of the inner ear in order to establish a methodological basis for further investigations into the pathophysiology and therapeutic monitoring of Meniere's disease. Sixteen patients (eight females, aged 38-71 years) with definite unilateral Meniere's disease were included in this study. Magnetic resonance (MR) cisternography with a T2-SPACE sequence was combined with a Real reconstruction inversion recovery (Real-IR) sequence for delineation of inner ear fluid spaces. Machine learning and automated local thresholding segmentation algorithms were applied for three-dimensional (3D) reconstruction and volumetric quantification of endolymphatic hydrops. Test-retest reliability was assessed by the intra-class coefficient; correlation of cochlear endolymph volume ratio with hearing function was assessed by the Pearson correlation coefficient. Endolymph volume ratios could be reliably measured in all patients, with a mean (range) value of 15 % (2-25) for the cochlea and 28 % (12-40) for the vestibulum. Test-retest reliability was excellent, with an intra-class coefficient of 0.99. Cochlear endolymphatic hydrops was significantly correlated with hearing loss (r = 0.747, p = 0.001). MR imaging after local contrast application and image processing, including machine learning and automated local thresholding, enable the volumetric quantification of endolymphatic hydrops. This allows for a quantitative assessment of the effect of therapeutic interventions on endolymphatic hydrops. (orig.)

  18. Touristic resources and factor intensity: Dominant factor content of trade in tourism. The case of the municipalities of Buenos Aires, Argentina

    Directory of Open Access Journals (Sweden)

    Natalia Porto

    2016-01-01

    Full Text Available The aim of this paper is to quantify one of the characteristics of the production function of the tourism sector in the province of Buenos Aires: the dominant factor content of their touristic resources, one simplified concept which shows the factors of production incorporated in goods. For its estimation and the touristic characterization of the different municipalities of the province, the following elements are used: the inventory of touristic resources of 134 municipalities of the province; their classification into the five categories listed by OEA; and the factor intensity of each category. One interesting result is that most municipalities with high touristic GDP show a dominant factor content of capital, the implication being that comparative advantage in the Province of Buenos Aires in Argentina is based on contemporary technical, scientific and artistic work. It may be concluded that there is place to exploit tourism in Argentina, what points to the need to accompany them with a correct design of public policies.

  19. Preliminary performance analysis of a transverse flow spectrally selective two-slab packed bed volumetric receiver

    CSIR Research Space (South Africa)

    Roos, TH

    2016-05-01

    Full Text Available stream_source_info Roos_2016_ABSTRACT.pdf.txt stream_content_type text/plain stream_size 2694 Content-Encoding UTF-8 stream_name Roos_2016_ABSTRACT.pdf.txt Content-Type text/plain; charset=UTF-8 21st SolarPACES... International Conference (SolarPACES 2015), 13-16 October 2015 Preliminary Performance Analysis of a Transverse Flow Spectrally Selective Two-slab Packed Bed Volumetric Receiver Thomas H. Roos1, a) and Thomas M. Harms2, b) 1Aeronautical Systems...

  20. Team performance in networked supervisory control of unmanned air vehicles: effects of automation, working memory, and communication content.

    Science.gov (United States)

    McKendrick, Ryan; Shaw, Tyler; de Visser, Ewart; Saqer, Haneen; Kidwell, Brian; Parasuraman, Raja

    2014-05-01

    Assess team performance within a net-worked supervisory control setting while manipulating automated decision aids and monitoring team communication and working memory ability. Networked systems such as multi-unmanned air vehicle (UAV) supervision have complex properties that make prediction of human-system performance difficult. Automated decision aid can provide valuable information to operators, individual abilities can limit or facilitate team performance, and team communication patterns can alter how effectively individuals work together. We hypothesized that reliable automation, higher working memory capacity, and increased communication rates of task-relevant information would offset performance decrements attributed to high task load. Two-person teams performed a simulated air defense task with two levels of task load and three levels of automated aid reliability. Teams communicated and received decision aid messages via chat window text messages. Task Load x Automation effects were significant across all performance measures. Reliable automation limited the decline in team performance with increasing task load. Average team spatial working memory was a stronger predictor than other measures of team working memory. Frequency of team rapport and enemy location communications positively related to team performance, and word count was negatively related to team performance. Reliable decision aiding mitigated team performance decline during increased task load during multi-UAV supervisory control. Team spatial working memory, communication of spatial information, and team rapport predicted team success. An automated decision aid can improve team performance under high task load. Assessment of spatial working memory and the communication of task-relevant information can help in operator and team selection in supervisory control systems.

  1. Factors Influencing Air Content of Pavement Concrete for Plateau Airport and Its Control Measures%高原机场道面混凝土含气量的影响因素及控制措施

    Institute of Scientific and Technical Information of China (English)

    岑国平; 洪刚; 王金华; 杨文科; 谭晓刚

    2012-01-01

    通过室内和现场试验,研究了青藏高原地区环境气压、拌合水温和细骨料含泥量对机场道面混凝土含气量的影响.结果表明,相同的配合比,高原地区混凝土含气量明显小于平原地区,引入的气泡数量少、消退快.砂子 含泥量对混凝土含气量和强度均有显著影响,拌合水温对含气量也有一定影响.为保证混凝土含气量,结合玉树机场实际情况,提出了相应的技术措施.%By indoor and in-situ experiments, the influences of environmental air pressure, temperature of mixing water and mud content of fine aggregate on the air content of airport pavement concrete were studied for Qinghai-Tibet plateau region. The results showed that the air content of concrete in plateau is much less than that in plain area at the same mix proportion. Number of air bubbles is less and the bubbles fade faster in plateau. The mud content of sand has a strong influence on both the air content and concrete strength. The temperature of mixing water also affects the air content of concrete. In order to ensure enough air content, some technique measures were put forward in the construction of Yushu Airport.

  2. Volumetric polymerization shrinkage of contemporary composite resins

    Directory of Open Access Journals (Sweden)

    Halim Nagem Filho

    2007-10-01

    Full Text Available The polymerization shrinkage of composite resins may affect negatively the clinical outcome of the restoration. Extensive research has been carried out to develop new formulations of composite resins in order to provide good handling characteristics and some dimensional stability during polymerization. The purpose of this study was to analyze, in vitro, the magnitude of the volumetric polymerization shrinkage of 7 contemporary composite resins (Definite, Suprafill, SureFil, Filtek Z250, Fill Magic, Alert, and Solitaire to determine whether there are differences among these materials. The tests were conducted with precision of 0.1 mg. The volumetric shrinkage was measured by hydrostatic weighing before and after polymerization and calculated by known mathematical equations. One-way ANOVA (a or = 0.05 was used to determine statistically significant differences in volumetric shrinkage among the tested composite resins. Suprafill (1.87±0.01 and Definite (1.89±0.01 shrank significantly less than the other composite resins. SureFil (2.01±0.06, Filtek Z250 (1.99±0.03, and Fill Magic (2.02±0.02 presented intermediate levels of polymerization shrinkage. Alert and Solitaire presented the highest degree of polymerization shrinkage. Knowing the polymerization shrinkage rates of the commercially available composite resins, the dentist would be able to choose between using composite resins with lower polymerization shrinkage rates or adopting technical or operational procedures to minimize the adverse effects deriving from resin contraction during light-activation.

  3. A SUBDIVISION SCHEME FOR VOLUMETRIC MODELS

    Institute of Scientific and Technical Information of China (English)

    GhulamMustafa; LiuXuefeng

    2005-01-01

    In this paper, a subdivision scheme which generalizes a surface scheme in previous papers to volume meshes is designed. The scheme exhibits significant control over shrink-age/size of volumetric models. It also has the ability to conveniently incorporate boundaries and creases into a smooth limit shape of models. The method presented here is much simpler and easier as compared to MacCracken and Joy's. This method makes no restrictions on the local topology of meshes. Particularly, it can be applied without any change to meshes of nonmanifold topology.

  4. IMITATION OF STANDARD VOLUMETRIC ACTIVITY METAL SAMPLES

    Directory of Open Access Journals (Sweden)

    A. I. Zhukouski

    2016-01-01

    Full Text Available Due to the specific character of problems in the field of ionizing radiation spectroscopy, the R&D and making process of standard volumetric activity metal samples (standard samples for calibration and verification of spectrometric equipment is not only expensive, but also requires the use of highly qualified experts and a unique specific equipment. Theoretical and experimental studies performed have shown the possibility to use imitators as a set of alternating point sources of gamma radiation and metal plates and their use along with standard volumetric activity metal samples for calibration of scintillation-based detectors used in radiation control in metallurgy. Response functions or instrumental spectra of such spectrometer to radionuclides like 137Cs, 134Cs, 152Eu, 154Eu, 60Co, 54Mn, 232Th, 226Ra, 65Zn, 125Sb+125mTe, 106Ru+106Rh, 94Nb, 110mAg, 233U, 234U, 235U and 238U are required for calibration in a given measurement geometry. Standard samples in the form of a probe made of melt metal of a certain diameter and height are used in such measurements. However, the production of reference materials is costly and even problematic for such radionuclides as 94Nb, 125Sb+125mTe, 234U, 235U  etc. A recognized solution to solve this problem is to use the Monte-Carlo simulation method. Instrumental experimental and theoretical spectra obtained by using standard samples and their imitators show a high compliance between experimental spectra of real samples and the theoretical ones of their Monte-Carlo models, between spectra of real samples and the ones of their imitators and finally, between experimental spectra of real sample imitators and the theoretical ones of their Monte-Carlo models. They also have shown the adequacy and consistency of the approach in using a combination of metal scattering layers and reference point gamma-ray sources instead of standard volumetric activity metal samples. As for using several reference point gamma-ray sources

  5. Magnetic volumetric hologram memory with magnetic garnet.

    Science.gov (United States)

    Nakamura, Yuichi; Takagi, Hiroyuki; Lim, Pang Boey; Inoue, Mitsuteru

    2014-06-30

    Holographic memory is a promising next-generation optical memory that has a higher recording density and a higher transfer rate than other types of memory. In holographic memory, magnetic garnet films can serve as rewritable holographic memory media by use of magneto-optical effect. We have now demonstrated that a magnetic hologram can be recorded volumetrically in a ferromagnetic garnet film and that the signal image can be reconstructed from it for the first time. In addition, multiplicity of the magnetic hologram was also confirmed; the image could be reconstructed from a spot overlapped by other spots.

  6. Influencing Factor Analysis and Control Measures of Concrete Air Content%混凝土含气量影响因素分析及控制措施

    Institute of Scientific and Technical Information of China (English)

    王春明

    2015-01-01

    结合现场监控试验,从混凝土的各个阶段着重对混凝土含气量的影响因素进行分析.通过对混凝土坍落度、砂率及砂细度模数、胶凝材料总量、混凝土运输车转速、引气剂掺量、布料振捣过程中的多种对比试验,得出相关数据说明影响的程度.%The field monitoring test has been adopted to analyze the influencing factors on air content of concrete at different stages. In addition, the influencing extent is explained on the basis of relevant data which are obtained through various contrast tests on concrete slump constant, modulus of grain ratio and grain fineness number, amount of gelling materials, rotate speed of concrete truck, amount of concrete air-entraining agent, materials distribution and vibration.

  7. Long term analysis of the biomass content in the feed of a waste-to-energy plant with oxygen-enriched combustion air.

    Science.gov (United States)

    Fellner, Johann; Cencic, Oliver; Zellinger, Günter; Rechberger, Helmut

    2011-10-01

    Thermal utilization of municipal solid waste and commercial wastes has become of increasing importance in European waste management. As waste materials are generally composed of fossil and biogenic materials, a part of the energy generated can be considered as renewable and is thus subsidized in some European countries. Analogously, CO(2) emissions of waste incinerators are only partly accounted for in greenhouse gas inventories. A novel approach for determining these fractions is the so-called balance method. In the present study, the implementation of the balance method on a waste-to-energy plant using oxygen-enriched combustion air was investigated. The findings of the 4-year application indicate on the one hand the general applicability and robustness of the method, and on the other hand the importance of reliable monitoring data. In particular, measured volume flows of the flue gas and the oxygen-enriched combustion air as well as corresponding O(2) and CO(2) contents should regularly be validated. The fraction of renewable (biogenic) energy generated throughout the investigated period amounted to between 27 and 66% for weekly averages, thereby denoting the variation in waste composition over time. The average emission factor of the plant was approximately 45 g CO(2) MJ(-1) energy input or 450 g CO(2) kg(-1) waste incinerated. The maximum error of the final result was about 16% (relative error), which was well above the error (<8%) of the balance method for plants with conventional oxygen supply.

  8. An initial assessment of spatial relationships between respiratory cases, soil metal content, air quality and deprivation indicators in Glasgow, Scotland, UK: relevance to the environmental justice agenda.

    Science.gov (United States)

    Morrison, S; Fordyce, F M; Scott, E Marian

    2014-04-01

    There is growing interest in links between poor health and socio-environmental inequalities (e.g. inferior housing, crime and industrial emissions) under the environmental justice agenda. The current project assessed associations between soil metal content, air pollution (NO2/PM10) and deprivation and health (respiratory case incidence) across Glasgow. This is the first time that both chemical land quality and air pollution have been assessed citywide in the context of deprivation and health for a major UK conurbation. Based on the dataset 'averages' for intermediate geography areas, generalised linear modelling of respiratory cases showed significant associations with overall soil metal concentration (p = 0.0367) and with deprivation (p soil metals, only nickel showed a significant relationship with respiratory cases (p = 0.0056). Whilst these associations could simply represent concordant lower soil metal concentrations and fewer respiratory cases in the rural versus the urban environment, they are interesting given (1) possible contributions from soil to air particulate loading and (2) known associations between airborne metals like nickel and health. This study also demonstrated a statistically significant correlation (-0.213; p soil metal concentration and deprivation across Glasgow. This highlights the fact that despite numerous regeneration programmes, the legacy of environmental pollution remains in post-industrial areas of Glasgow many decades after heavy industry has declined. Further epidemiological investigations would be required to determine whether there are any causal links between soil quality and population health/well-being. However, the results of this study suggest that poor soil quality warrants greater consideration in future health and socio-environmental inequality assessments.

  9. Air Pollution

    Science.gov (United States)

    ... to view this content or go to source URL . What NIEHS is Doing on Air Pollution Who ... Junction Last Reviewed: February 06, 2017 This page URL: NIEHS website: https://www.niehs.nih.gov/ Email ...

  10. The Influence of Aerosol Concentration on Changes in the Volumetric Activities of Indoor Radon Short-Term Decay Products

    Directory of Open Access Journals (Sweden)

    Diana Politova

    2011-02-01

    Full Text Available The article describes the influence of aerosol concentration on changes in the volumetric activities of indoor radon short-term decay products. The concentration of aerosol in the air, equilibrium factors and unattached fraction were measured under normal living conditions when the concentration of aerosol increases, i.e. burning a candle or frankincense in accommodations, smoke-filled accommodations, a steamy kitchen etc. It has been established that when the concentration of aerosol in the air rises, the number of free atoms of radon short-term decay products attached to aerosol particles also increases, and therefore higher volumetric activity of alpha particles is fixed. A tight positive connection of the correlation between equilibrium factor (F and aerosol particle concentration in the air of accommodations as well as a negative correlation between unattached fraction and an equilibrium factor have been determined.Article in Lithuanian

  11. A new laboratory-scale experimental facility for detailed aerothermal characterizations of volumetric absorbers

    Science.gov (United States)

    Gomez-Garcia, Fabrisio; Santiago, Sergio; Luque, Salvador; Romero, Manuel; Gonzalez-Aguilar, Jose

    2016-05-01

    This paper describes a new modular laboratory-scale experimental facility that was designed to conduct detailed aerothermal characterizations of volumetric absorbers for use in concentrating solar power plants. Absorbers are generally considered to be the element with the highest potential for efficiency gains in solar thermal energy systems. The configu-ration of volumetric absorbers enables concentrated solar radiation to penetrate deep into their solid structure, where it is progressively absorbed, prior to being transferred by convection to a working fluid flowing through the structure. Current design trends towards higher absorber outlet temperatures have led to the use of complex intricate geometries in novel ceramic and metallic elements to maximize the temperature deep inside the structure (thus reducing thermal emission losses at the front surface and increasing efficiency). Although numerical models simulate the conjugate heat transfer mechanisms along volumetric absorbers, they lack, in many cases, the accuracy that is required for precise aerothermal validations. The present work aims to aid this objective by the design, development, commissioning and operation of a new experimental facility which consists of a 7 kWe (1.2 kWth) high flux solar simulator, a radiation homogenizer, inlet and outlet collector modules and a working section that can accommodate volumetric absorbers up to 80 mm × 80 mm in cross-sectional area. Experimental measurements conducted in the facility include absorber solid temperature distributions along its depth, inlet and outlet air temperatures, air mass flow rate and pressure drop, incident radiative heat flux, and overall thermal efficiency. In addition, two windows allow for the direct visualization of the front and rear absorber surfaces, thus enabling full-coverage surface temperature measurements by thermal imaging cameras. This paper presents the results from the aerothermal characterization of a siliconized silicon

  12. Disentangling volumetric and hydrational properties of proteins.

    Science.gov (United States)

    Voloshin, Vladimir P; Medvedev, Nikolai N; Smolin, Nikolai; Geiger, Alfons; Winter, Roland

    2015-02-05

    We used molecular dynamics simulations of a typical monomeric protein, SNase, in combination with Voronoi-Delaunay tessellation to study and analyze the temperature dependence of the apparent volume, Vapp, of the solute. We show that the void volume, VB, created in the boundary region between solute and solvent, determines the temperature dependence of Vapp to a major extent. The less pronounced but still significant temperature dependence of the molecular volume of the solute, VM, is essentially the result of the expansivity of its internal voids, as the van der Waals contribution to VM is practically independent of temperature. Results for polypeptides of different chemical nature feature a similar temperature behavior, suggesting that the boundary/hydration contribution seems to be a universal part of the temperature dependence of Vapp. The results presented here shine new light on the discussion surrounding the physical basis for understanding and decomposing the volumetric properties of proteins and biomolecules in general.

  13. All Photons Imaging Through Volumetric Scattering

    Science.gov (United States)

    Satat, Guy; Heshmat, Barmak; Raviv, Dan; Raskar, Ramesh

    2016-01-01

    Imaging through thick highly scattering media (sample thickness ≫ mean free path) can realize broad applications in biomedical and industrial imaging as well as remote sensing. Here we propose a computational “All Photons Imaging” (API) framework that utilizes time-resolved measurement for imaging through thick volumetric scattering by using both early arrived (non-scattered) and diffused photons. As opposed to other methods which aim to lock on specific photons (coherent, ballistic, acoustically modulated, etc.), this framework aims to use all of the optical signal. Compared to conventional early photon measurements for imaging through a 15 mm tissue phantom, our method shows a two fold improvement in spatial resolution (4db increase in Peak SNR). This all optical, calibration-free framework enables widefield imaging through thick turbid media, and opens new avenues in non-invasive testing, analysis, and diagnosis. PMID:27683065

  14. FELIX 3D display: an interactive tool for volumetric imaging

    Science.gov (United States)

    Langhans, Knut; Bahr, Detlef; Bezecny, Daniel; Homann, Dennis; Oltmann, Klaas; Oltmann, Krischan; Guill, Christian; Rieper, Elisabeth; Ardey, Goetz

    2002-05-01

    The FELIX 3D display belongs to the class of volumetric displays using the swept volume technique. It is designed to display images created by standard CAD applications, which can be easily imported and interactively transformed in real-time by the FELIX control software. The images are drawn on a spinning screen by acousto-optic, galvanometric or polygon mirror deflection units with integrated lasers and a color mixer. The modular design of the display enables the user to operate with several equal or different projection units in parallel and to use appropriate screens for the specific purpose. The FELIX 3D display is a compact, light, extensible and easy to transport system. It mainly consists of inexpensive standard, off-the-shelf components for an easy implementation. This setup makes it a powerful and flexible tool to keep track with the rapid technological progress of today. Potential applications include imaging in the fields of entertainment, air traffic control, medical imaging, computer aided design as well as scientific data visualization.

  15. Optical artefact characterization and correction in volumetric scintillation dosimetry

    Science.gov (United States)

    Robertson, Daniel; Hui, Cheukkai; Archambault, Louis; Mohan, Radhe; Beddar, Sam

    2014-01-01

    The goals of this study were (1) to characterize the optical artefacts affecting measurement accuracy in a volumetric liquid scintillator detector, and (2) to develop methods to correct for these artefacts. The optical artefacts addressed were photon scattering, refraction, camera perspective, vignetting, lens distortion, the lens point spread function, stray radiation, and noise in the camera. These artefacts were evaluated by theoretical and experimental means, and specific correction strategies were developed for each artefact. The effectiveness of the correction methods was evaluated by comparing raw and corrected images of the scintillation light from proton pencil beams against validated Monte Carlo calculations. Blurring due to the lens and refraction at the scintillator tank-air interface were found to have the largest effect on the measured light distribution, and lens aberrations and vignetting were important primarily at the image edges. Photon scatter in the scintillator was not found to be a significant source of artefacts. The correction methods effectively mitigated the artefacts, increasing the average gamma analysis pass rate from 66% to 98% for gamma criteria of 2% dose difference and 2 mm distance to agreement. We conclude that optical artefacts cause clinically meaningful errors in the measured light distribution, and we have demonstrated effective strategies for correcting these optical artefacts.

  16. A Technique for Volumetric CSG Based on Morphology

    DEFF Research Database (Denmark)

    Bærentzen, Jakob Andreas; Christensen, Niels Jørgen

    2001-01-01

    In this paper, a new technique for volumetric CSG is presented. The technique requires the input volumes to correspond to solids which fulfill a voxelization suitability criterion. Assume the CSG operation is union. The volumetric union of two such volumes is defined in terms of the voxelization...

  17. Experimental evaluation and simulation of volumetric shrinkage and warpage on polymeric composite reinforced with short natural fibers

    Science.gov (United States)

    Santos, Jonnathan D.; Fajardo, Jorge I.; Cuji, Alvaro R.; García, Jaime A.; Garzón, Luis E.; López, Luis M.

    2015-09-01

    A polymeric natural fiber-reinforced composite is developed by extrusion and injection molding process. The shrinkage and warpage of high-density polyethylene reinforced with short natural fibers of Guadua angustifolia Kunth are analyzed by experimental measurements and computer simulations. Autodesk Moldflow® and Solid Works® are employed to simulate both volumetric shrinkage and warpage of injected parts at different configurations: 0 wt.%, 20 wt.%, 30 wt.% and 40 wt.% reinforcing on shrinkage and warpage behavior of polymer composite. Become evident the restrictive effect of reinforcing on the volumetric shrinkage and warpage of injected parts. The results indicate that volumetric shrinkage of natural composite is reduced up to 58% with fiber increasing, whereas the warpage shows a reduction form 79% to 86% with major fiber content. These results suggest that it is a highly beneficial use of natural fibers to improve the assembly properties of polymeric natural fiber-reinforced composites.

  18. A Solar Volumetric Receiver: Influence of Absorbing Cells Configuration on Device Thermal Performance

    Science.gov (United States)

    Yilbas, B. S.; Shuja, S. Z.

    2017-01-01

    Thermal performance of a solar volumetric receiver incorporating the different cell geometric configurations is investigated. Triangular, hexagonal, and rectangular absorbing cells are incorporated in the analysis. The fluid volume fraction, which is the ratio of the volume of the working fluid over the total volume of solar volumetric receiver, is introduced to assess the effect of cell size on the heat transfer rates in the receiver. In this case, reducing the fluid volume fraction corresponds to increasing cell size in the receiver. SiC is considered as the cell material, and air is used as the working fluid in the receiver. The Lambert's Beer law is incorporated to account for the solar absorption in the receiver. A finite element method is used to solve the governing equation of flow and heat transfer. It is found that the fluid volume fraction has significant effect on the flow field in the solar volumetric receiver, which also modifies thermal field in the working fluid. The triangular absorbing cell gives rise to improved effectiveness of the receiver and then follows the hexagonal and rectangular cells. The second law efficiency of the receiver remains high when hexagonal cells are used. This occurs for the fluid volume fraction ratio of 0.5.

  19. On the Correlation between Air Content and Air Bubble Parameters Frost Resistance Performance of High Fly Ash Content Concrete%关于大掺量粉煤灰混凝土含气量、气泡参数表征抗冻能力相关性的探讨

    Institute of Scientific and Technical Information of China (English)

    艾红梅; 戴碧琳; 郭建华; 杨晨光

    2015-01-01

    鉴于冻融作用对大掺量粉煤灰混凝土( High Fly ash Content Concrete,HFCC)造成的破坏较为严重,对国内外的研究情况进行了分析,总结了现阶段大掺量粉煤灰混凝土抗冻性能的研究进展。主要对混凝土拌合物含气量和硬化混凝土气泡参数表征HFCC抗冻性的科学性和可行性进行了分析,并且对二者的相关性进行探讨。%Given the freeze-thaw effect on high fly ash content concrete ( HFCC ) is relatively serious,the paper analyzes the domestic and foreign research and summarizes the present research progress of antifreeze performance of concrete with high volume of fly ash. This paper mainly analyzes the science and feasibility of concrete mixture air content and hardened concrete bubble parameters HFCC frost resistance and explores the correlation between the two.

  20. Design and Range of Application of Slot Bushings with Volumetric Orifice Fields

    Institute of Scientific and Technical Information of China (English)

    ULYBYSHEV V. V.; VASEKIN V. V.; PERELMAN S. L.

    2012-01-01

    A design of a slot bushing with a volumetric field has been developed,which allows to produce continuous fibers from melts with difficult processing characteristics in order to produce fibers with better operating characteristics.The operability of the design was confirrned when solving two problems of special technological complexity.1.400- and 800-orifice bushings for production of continuous fibers from the basalt melt have been developed and recommended for manufacture.2.The process of production of continuous fibers from standard glass using 2400-orifice bushing with perforated plates instead of orifice tips without air cooling,has been realized for the first time.

  1. Iterative reconstruction of volumetric particle distribution

    Science.gov (United States)

    Wieneke, Bernhard

    2013-02-01

    For tracking the motion of illuminated particles in space and time several volumetric flow measurement techniques are available like 3D-particle tracking velocimetry (3D-PTV) recording images from typically three to four viewing directions. For higher seeding densities and the same experimental setup, tomographic PIV (Tomo-PIV) reconstructs voxel intensities using an iterative tomographic reconstruction algorithm (e.g. multiplicative algebraic reconstruction technique, MART) followed by cross-correlation of sub-volumes computing instantaneous 3D flow fields on a regular grid. A novel hybrid algorithm is proposed here that similar to MART iteratively reconstructs 3D-particle locations by comparing the recorded images with the projections calculated from the particle distribution in the volume. But like 3D-PTV, particles are represented by 3D-positions instead of voxel-based intensity blobs as in MART. Detailed knowledge of the optical transfer function and the particle image shape is mandatory, which may differ for different positions in the volume and for each camera. Using synthetic data it is shown that this method is capable of reconstructing densely seeded flows up to about 0.05 ppp with similar accuracy as Tomo-PIV. Finally the method is validated with experimental data.

  2. Effect of Volatility on Air-Fuel Ratio Distribution and Torque Output of a Carbureted Light Aircraft Piston Engine.

    Science.gov (United States)

    1982-03-01

    Positive displacement fuel flow sensor Burette type volumetric fuel flowmeter(2) Meriam laminar airflow meter Lamdascan air-fuel ratio meter Lebow inline...therefore the resulting data was not utilized. The volumetric flowrate of engine intake air was calculated from the pressure drop across a Meriam Model 50MC2

  3. Characterizing volumetric deformation behavior of naturally occuring bituminous sand materials

    CSIR Research Space (South Africa)

    Anochie-Boateng, Joseph

    2009-05-01

    Full Text Available newly proposed hydrostatic compression test procedure. The test procedure applies field loading conditions of off-road construction and mining equipment to closely simulate the volumetric deformation and stiffness behaviour of oil sand materials. Based...

  4. Hyperspectral image classification based on volumetric texture and dimensionality reduction

    Science.gov (United States)

    Su, Hongjun; Sheng, Yehua; Du, Peijun; Chen, Chen; Liu, Kui

    2015-06-01

    A novel approach using volumetric texture and reduced-spectral features is presented for hyperspectral image classification. Using this approach, the volumetric textural features were extracted by volumetric gray-level co-occurrence matrices (VGLCM). The spectral features were extracted by minimum estimated abundance covariance (MEAC) and linear prediction (LP)-based band selection, and a semi-supervised k-means (SKM) clustering method with deleting the worst cluster (SKMd) bandclustering algorithms. Moreover, four feature combination schemes were designed for hyperspectral image classification by using spectral and textural features. It has been proven that the proposed method using VGLCM outperforms the gray-level co-occurrence matrices (GLCM) method, and the experimental results indicate that the combination of spectral information with volumetric textural features leads to an improved classification performance in hyperspectral imagery.

  5. Designing remote web-based mechanical-volumetric flow meter ...

    African Journals Online (AJOL)

    ... remote web-based mechanical-volumetric flow meter reading systems based on ... damage and also provides the ability to control and manage consumption. ... existing infrastructure of the telecommunications is used in data transmission.

  6. Increasing the volumetric efficiency of Diesel engines by intake pipes

    Science.gov (United States)

    List, Hans

    1933-01-01

    Development of a method for calculating the volumetric efficiency of piston engines with intake pipes. Application of this method to the scavenging pumps of two-stroke-cycle engines with crankcase scavenging and to four-stroke-cycle engines. The utility of the method is demonstrated by volumetric-efficiency tests of the two-stroke-cycle engines with crankcase scavenging. Its practical application to the calculation of intake pipes is illustrated by example.

  7. Serial volumetric registration of pulmonary CT studies

    Science.gov (United States)

    Silva, José Silvestre; Silva, Augusto; Sousa Santos, Beatriz

    2008-03-01

    Detailed morphological analysis of pulmonary structures and tissue, provided by modern CT scanners, is of utmost importance as in the case of oncological applications both for diagnosis, treatment, and follow-up. In this case, a patient may go through several tomographic studies throughout a period of time originating volumetric sets of image data that must be appropriately registered in order to track suspicious radiological findings. The structures or regions of interest may change their position or shape in CT exams acquired at different moments, due to postural, physiologic or pathologic changes, so, the exams should be registered before any follow-up information can be extracted. Postural mismatching throughout time is practically impossible to avoid being particularly evident when imaging is performed at the limiting spatial resolution. In this paper, we propose a method for intra-patient registration of pulmonary CT studies, to assist in the management of the oncological pathology. Our method takes advantage of prior segmentation work. In the first step, the pulmonary segmentation is performed where trachea and main bronchi are identified. Then, the registration method proceeds with a longitudinal alignment based on morphological features of the lungs, such as the position of the carina, the pulmonary areas, the centers of mass and the pulmonary trans-axial principal axis. The final step corresponds to the trans-axial registration of the corresponding pulmonary masked regions. This is accomplished by a pairwise sectional registration process driven by an iterative search of the affine transformation parameters leading to optimal similarity metrics. Results with several cases of intra-patient, intra-modality registration, up to 7 time points, show that this method provides accurate registration which is needed for quantitative tracking of lesions and the development of image fusion strategies that may effectively assist the follow-up process.

  8. Volumetric optoacoustic monitoring of endovenous laser treatments

    Science.gov (United States)

    Fehm, Thomas F.; Deán-Ben, Xosé L.; Schaur, Peter; Sroka, Ronald; Razansky, Daniel

    2016-03-01

    Chronic venous insufficiency (CVI) is one of the most common medical conditions with reported prevalence estimates as high as 30% in the adult population. Although conservative management with compression therapy may improve the symptoms associated with CVI, healing often demands invasive procedures. Besides established surgical methods like vein stripping or bypassing, endovenous laser therapy (ELT) emerged as a promising novel treatment option during the last 15 years offering multiple advantages such as less pain and faster recovery. Much of the treatment success hereby depends on monitoring of the treatment progression using clinical imaging modalities such as Doppler ultrasound. The latter however do not provide sufficient contrast, spatial resolution and three-dimensional imaging capacity which is necessary for accurate online lesion assessment during treatment. As a consequence, incidence of recanalization, lack of vessel occlusion and collateral damage remains highly variable among patients. In this study, we examined the capacity of volumetric optoacoustic tomography (VOT) for real-time monitoring of ELT using an ex-vivo ox foot model. ELT was performed on subcutaneous veins while optoacoustic signals were acquired and reconstructed in real-time and at a spatial resolution in the order of 200μm. VOT images showed spatio-temporal maps of the lesion progression, characteristics of the vessel wall, and position of the ablation fiber's tip during the pull back. It was also possible to correlate the images with the temperature elevation measured in the area adjacent to the ablation spot. We conclude that VOT is a promising tool for providing online feedback during endovenous laser therapy.

  9. Treatment planning for volumetric modulated arc therapy

    Energy Technology Data Exchange (ETDEWEB)

    Bedford, James L. [Joint Department of Physics, Institute of Cancer Research and The Royal Marsden NHS Foundation Trust, Downs Road, Sutton, Surrey SM2 5PT (United Kingdom)

    2009-11-15

    Purpose: Volumetric modulated arc therapy (VMAT) is a specific type of intensity-modulated radiation therapy (IMRT) in which the gantry speed, multileaf collimator (MLC) leaf position, and dose rate vary continuously during delivery. A treatment planning system for VMAT is presented. Methods: Arc control points are created uniformly throughout one or more arcs. An iterative least-squares algorithm is used to generate a fluence profile at every control point. The control points are then grouped and all of the control points in a given group are used to approximate the fluence profiles. A direct-aperture optimization is then used to improve the solution, taking into account the allowed range of leaf motion of the MLC. Dose is calculated using a fast convolution algorithm and the motion between control points is approximated by 100 interpolated dose calculation points. The method has been applied to five cases, consisting of lung, rectum, prostate and seminal vesicles, prostate and pelvic lymph nodes, and head and neck. The resulting plans have been compared with segmental (step-and-shoot) IMRT and delivered and verified on an Elekta Synergy to ensure practicality. Results: For the lung, prostate and seminal vesicles, and rectum cases, VMAT provides a plan of similar quality to segmental IMRT but with faster delivery by up to a factor of 4. For the prostate and pelvic nodes and head-and-neck cases, the critical structure doses are reduced with VMAT, both of these cases having a longer delivery time than IMRT. The plans in general verify successfully, although the agreement between planned and measured doses is not very close for the more complex cases, particularly the head-and-neck case. Conclusions: Depending upon the emphasis in the treatment planning, VMAT provides treatment plans which are higher in quality and/or faster to deliver than IMRT. The scheme described has been successfully introduced into clinical use.

  10. Appendix to Health and Safety Laboratory environmental quarterly, March 1, 1976--June 1, 1976. [Tabulated data on content of lead in surface air and /sup 7/Be, /sup 95/Zr, /sup 137/Cs, /sup 144/Ce, and /sup 90/Sr in surface air, milk, drinking water, and foods sampled in USA

    Energy Technology Data Exchange (ETDEWEB)

    Hardy, E.P. Jr.

    1976-07-01

    Tabulated data are presented on: the monthly deposition of /sup 89/Sr and /sup 90/Sr at some 100 world land sites; the content of lead and /sup 7/Be, /sup 95/Zr, /sup 137/Cs, and /sup 144/Ce in samples of surface air from various world sites; and the content of /sup 90/Sr in samples of milk, drinking water, and animal and human diets collected at various locations throughout the USA. (CH)

  11. Recovery and characterization of Balanites aegyptiaca Del. kernel proteins. Effect of defatting, air classification, wet sieving and aqueous ethanol treatment on solubility, digestibility, amino acid composition and sapogenin content.

    Science.gov (United States)

    Mohamed, A M; Wolf, W; Spiess, W E

    2000-02-01

    In order to find alternative protein sources in African regions where protein deficiency in nutrition is prevailing, solubility, in-vitro digestibility, amino acid composition and chemical score of Balanites aegyptiaca Del. kernel proteins were investigated as a function of different processing steps including defatting, air classification, wet sieving and aqueous ethanol treatment. Air classification delivered a fine fraction of 58.1% of the total protein. Applying a wet sieving process, a protein concentrate of 72.9% protein content was achieved but the recovery was very low (35.6%). However, in case of isoelectric precipitation followed by aqueous ethanol treatment both protein content (78.2%) and recovery (53.7%) were high. Data concerning the chemical score revealed, that lysine content of the defatted kernel flour amounted to 74.2% of the recommended FAO/WHO standard level. In-vitro protein digestibility was found to be higher than of legume proteins. The digestible protein of the full fat flour, defatted flour, air classified and wet sieved fine fractions and protein concentrate were 91.9, 93.7, 82.0, 86.4 and 94.2%, respectively. The sapogenin content per 100 g protein of the investigated protein preparations was significantly lower (46% to 62%) than of the initial material (oilcake).

  12. Visualization and volumetric structures from MR images of the brain

    Energy Technology Data Exchange (ETDEWEB)

    Parvin, B.; Johnston, W.; Robertson, D.

    1994-03-01

    Pinta is a system for segmentation and visualization of anatomical structures obtained from serial sections reconstructed from magnetic resonance imaging. The system approaches the segmentation problem by assigning each volumetric region to an anatomical structure. This is accomplished by satisfying constraints at the pixel level, slice level, and volumetric level. Each slice is represented by an attributed graph, where nodes correspond to regions and links correspond to the relations between regions. These regions are obtained by grouping pixels based on similarity and proximity. The slice level attributed graphs are then coerced to form a volumetric attributed graph, where volumetric consistency can be verified. The main novelty of our approach is in the use of the volumetric graph to ensure consistency from symbolic representations obtained from individual slices. In this fashion, the system allows errors to be made at the slice level, yet removes them when the volumetric consistency cannot be verified. Once the segmentation is complete, the 3D surfaces of the brain can be constructed and visualized.

  13. Soft bilateral filtering volumetric shadows using cube shadow maps

    Science.gov (United States)

    Ali, Hatam H.; Sunar, Mohd Shahrizal; Kolivand, Hoshang

    2017-01-01

    Volumetric shadows often increase the realism of rendered scenes in computer graphics. Typical volumetric shadows techniques do not provide a smooth transition effect in real-time with conservation on crispness of boundaries. This research presents a new technique for generating high quality volumetric shadows by sampling and interpolation. Contrary to conventional ray marching method, which requires extensive time, this proposed technique adopts downsampling in calculating ray marching. Furthermore, light scattering is computed in High Dynamic Range buffer to generate tone mapping. The bilateral interpolation is used along a view rays to smooth transition of volumetric shadows with respect to preserving-edges. In addition, this technique applied a cube shadow map to create multiple shadows. The contribution of this technique isreducing the number of sample points in evaluating light scattering and then introducing bilateral interpolation to improve volumetric shadows. This contribution is done by removing the inherent deficiencies significantly in shadow maps. This technique allows obtaining soft marvelous volumetric shadows, having a good performance and high quality, which show its potential for interactive applications. PMID:28632740

  14. Si含量对6061型材在线风冷淬火性能的影响%Effect of Si Content on Properties of 6061 Profile Online Air-cooling Quenching

    Institute of Scientific and Technical Information of China (English)

    王奕雷

    2016-01-01

    研究了Si元素在6061合金中的含量对在线风冷淬火力学性能的影响,确定了最佳合金含量、淬火温度、风冷淬火条件,解决了型材在线风冷淬火性能不达标的问题。%The effect of Si content on the mechanical properties of 6061 alloy online air-cooling quenching was studied. The optimum alloy content, quenching temperature and cooling condition were determined. The problem of on-line air-cooling quenching performance substandard is solved.

  15. Optimisasi Suhu Pemanasan dan Kadar Air pada Produksi Pati Talas Kimpul Termodifikasi dengan Teknik Heat Moisture Treatment (HMT (Optimization of Heating Temperature and Moisture Content on the Production of Modified Cocoyam Starch Using Heat Moisture Treatment (HMT Technique

    Directory of Open Access Journals (Sweden)

    I Nengah Kencana Putra

    2016-12-01

    Full Text Available One of the physically starch modification technique is heat-moisture treatment (HMT. This technique can increase the resistance of starch to heat, mechanical treatment, and acid during processing.  This research aimed to find out the influence of heating temperature and moisture content in the modification process of cocoyam starch  with HMT techniques on the characteristic of product, and then to determine the optimum heating temperature and moisture content in the process. The research was designed with a complete randomized design (CRD with two factors factorial experiment.  The first factor was temperature of the heating consists of 3 levels namely 100 °C, 110 °C, and 120 °C. The second factor was the moisture content of starch which consists of 4 levels, namely 15 %, 20 %, 25 %, and 30 %. The results showed that the heating temperature and moisture content significantly affected water content, amylose content and swelling power of modified cocoyam starch product, but the treatment had no significant effect on the solubility of the product. HMT process was able to change the type of cocoyam starch from type B to type C. The optimum heating temperature and water content on modified cocoyam starch production process was 110 °C and 30 % respectively. Such treatment resulted in a modified cocoyam starch with moisture content of 6.50 %, 50,14 % amylose content, swelling power of 7.90, 0.0009% solubility, paste clarity of 96.310 % T, and was classified as a type C starch.   ABSTRAK Salah satu teknik modifikasi pati secara fisik adalah teknik Heat Moisture Treatment (HMT. Teknik ini dapat meningkatkan ketahanan pati terhadap panas, perlakuan mekanik, dan asam selama pengolahan. Penelitian ini bertujuan untuk mengetahui pengaruh suhu dan kadar air pada proses modifikasi pati talas kimpul dengan teknik HMT terhadap karakteristik produk, dan selanjutnya menentukan suhu dan kadar air yang optimal dalam proses tersebut. Penelitian ini dirancang

  16. 含气量对激光空泡在刚性壁面空蚀的影响%Influence of air content on cavitation erosion by laser-generated bubble near rigid boundaries

    Institute of Scientific and Technical Information of China (English)

    刘涛; 王江安; 宗思光; 梁善永; 张显峰

    2012-01-01

    采用强脉冲激光器设计液体环境下刚性壁面空蚀实验平台,改变液体中含气量,利用高速相机观察不同含气量条件下激光空泡在壁面附近的脉动过程,并对刚性壁面造成的空蚀结果进行了观测.实验研究发现,随着液体中相对空气含量的提高,激光空泡脉动的最大尺寸增大,空泡的膨胀运动变剧烈,溃灭运动速度降低,空泡的溃灭强度降低,从而影响到溃灭冲击波和壁面微射流对刚性壁面的冲击速度,减弱了壁面空蚀,而液体中含气量的提高能够降低激光空泡对刚性壁面的空蚀程度.%In the designed experimental system of laser-generated bubble near a rigid boundary in water, the effect of air content on cavitation erosion was studied by changing the air content and using high speed camera system. The experimental results indicate that the maximum size of the first cavitation bubble collapse increases with improving the air content in water. Improving the air content may increase the period of the cavitation bubble collapse, weaken the strength of the cavitation bubble collapse, reduce the micro liquid jet velocity, decrease the shock wave pressure to the rigid boundary, and reduce the cavitation damage on the surface of the rigid boundaries.

  17. A high specific capacity membraneless aluminum-air cell operated with an inorganic/organic hybrid electrolyte

    Science.gov (United States)

    Chen, Binbin; Leung, Dennis Y. C.; Xuan, Jin; Wang, Huizhi

    2016-12-01

    Aluminum-air cells have attracted a lot of interests because they have the highest volumetric capacity density in theory among the different metal-air systems. To overcome the self-discharge issue of aluminum, a microfluidic aluminum-air cell working with KOH methanol-based anolyte was developed in this work. A specific capacity up to 2507 mAh g-1 (that is, 84.1% of the theoretical value) was achieved experimentally. The KOH concentration and water content in the methanol-based anolyte were found to have direct influence on the cell performance. A possible mechanism of the aluminum reactions in KOH methanol-based electrolyte was proposed to explain the observed phenomenon.

  18. Improved volumetric imaging in tomosynthesis using combined multiaxial sweeps.

    Science.gov (United States)

    Gersh, Jacob A; Wiant, David B; Best, Ryan C M; Bennett, Marcus C; Munley, Michael T; King, June D; McKee, Mahta M; Baydush, Alan H

    2010-09-03

    This study explores the volumetric reconstruction fidelity attainable using tomosynthesis with a kV imaging system which has a unique ability to rotate isocentrically and with multiple degrees of mechanical freedom. More specifically, we seek to investigate volumetric reconstructions by combining multiple limited-angle rotational image acquisition sweeps. By comparing these reconstructed images with those of a CBCT reconstruction, we can gauge the volumetric fidelity of the reconstructions. In surgical situations, the described tomosynthesis-based system could provide high-quality volumetric imaging without requiring patient motion, even with rotational limitations present. Projections were acquired using the Digital Integrated Brachytherapy Unit, or IBU-D. A phantom was used which contained several spherical objects of varying contrast. Using image projections acquired during isocentric sweeps around the phantom, reconstructions were performed by filtered backprojection. For each image acquisition sweep configuration, a contrasting sphere is analyzed using two metrics and compared to a gold standard CBCT reconstruction. Since the intersection of a reconstructed sphere and an imaging plane is ideally a circle with an eccentricity of zero, the first metric presented compares the effective eccentricity of intersections of reconstructed volumes and imaging planes. As another metric of volumetric reconstruction fidelity, the volume of one of the contrasting spheres was determined using manual contouring. By comparing these manually delineated volumes with a CBCT reconstruction, we can gauge the volumetric fidelity of reconstructions. The configuration which yielded the highest overall volumetric reconstruction fidelity, as determined by effective eccentricities and volumetric contouring, consisted of two orthogonally-offset 60° L-arm sweeps and a single C-arm sweep which shared a pivot point with one the L-arm sweeps. When compared to a similar configuration that

  19. Aspects of volumetric efficiency measurement for reciprocating engines

    Directory of Open Access Journals (Sweden)

    Pešić Radivoje B.

    2013-01-01

    Full Text Available The volumetric efficiency significantly influences engine output. Both design and dimensions of an intake and exhaust system have large impact on volumetric efficiency. Experimental equipment for measuring of airflow through the engine, which is placed in the intake system, may affect the results of measurements and distort the real picture of the impact of individual structural factors. This paper deals with the problems of experimental determination of intake airflow using orifice plates and the influence of orifice plate diameter on the results of the measurements. The problems of airflow measurements through a multi-process Otto/Diesel engine were analyzed. An original method for determining volumetric efficiency was developed based on in-cylinder pressure measurement during motored operation, and appropriate calibration of the experimental procedure was performed. Good correlation between the results of application of the original method for determination of volumetric efficiency and the results of theoretical model used in research of influence of the intake pipe length on volumetric efficiency was determined. [Acknowledgments. The paper is the result of the research within the project TR 35041 financed by the Ministry of Science and Technological Development of the Republic of Serbia

  20. A high volume, high throughput volumetric sorption analyzer

    Science.gov (United States)

    Soo, Y. C.; Beckner, M.; Romanos, J.; Wexler, C.; Pfeifer, P.; Buckley, P.; Clement, J.

    2011-03-01

    In this talk we will present an overview of our new Hydrogen Test Fixture (HTF) constructed by the Midwest Research Institute for The Alliance for Collaborative Research in Alternative Fuel Technology to test activated carbon monoliths for hydrogen gas storage. The HTF is an automated, computer-controlled volumetric instrument for rapid screening and manipulation of monoliths under an inert atmosphere (to exclude degradation of carbon from exposure to oxygen). The HTF allows us to measure large quantity (up to 500 g) of sample in a 0.5 l test tank, making our results less sensitive to sample inhomogeneity. The HTF can measure isotherms at pressures ranging from 1 to 300 bar at room temperature. For comparison, other volumetric instruments such as Hiden Isochema's HTP-1 Volumetric Analyser can only measure carbon samples up to 150 mg at pressures up to 200 bar. Work supported by the US DOD Contract # N00164-08-C-GS37.

  1. Volumetric (3D) compressive sensing spectral domain optical coherence tomography.

    Science.gov (United States)

    Xu, Daguang; Huang, Yong; Kang, Jin U

    2014-11-01

    In this work, we proposed a novel three-dimensional compressive sensing (CS) approach for spectral domain optical coherence tomography (SD OCT) volumetric image acquisition and reconstruction. Instead of taking a spectral volume whose size is the same as that of the volumetric image, our method uses a sub set of the original spectral volume that is under-sampled in all three dimensions, which reduces the amount of spectral measurements to less than 20% of that required by the Shan-non/Nyquist theory. The 3D image is recovered from the under-sampled spectral data dimension-by-dimension using the proposed three-step CS reconstruction strategy. Experimental results show that our method can significantly reduce the sampling rate required for a volumetric SD OCT image while preserving the image quality.

  2. Influence of cobalt and manganese content on the dehydrogenation capacity and kinetics of air-exposed LaNi{sub 5+x}-type alloys in solid gas and electrochemical reactions

    Energy Technology Data Exchange (ETDEWEB)

    Raekelboom, E.; Cuevas, F.; Percheron-Guegan, A. [Laboratoire de Chimie Metallurgique des Terres Rares CNRS, 2-8 rue Henri Dunant, 94320 Thiais (France); Knosp, B. [SAFT, 111 bd. Alfred Daney, 33074 Bordeaux (France)

    2007-07-10

    The effect of cobalt and manganese content on the dehydrogenation properties of air-exposed MmB{sub 5+x}-type (Mm = mischmetal; B = Ni, Al, Co and Mn) alloys was investigated both in solid gas and electrochemical reactions. The cobalt and manganese content were varied separately while keeping constant the plateau pressure of the hydrides. The increase of the cobalt content leads to a decrease of the hydrogen capacity whereas the manganese content has no much effect. In solid gas reactions, the kinetics were found to be limited by the hydrogen diffusion through the surface oxidation layer. As for the electrochemistry, the kinetics are limited by a corrosion layer formed in alkaline medium. The desorption rates for both processes increase as the cobalt or manganese content decreases. This is thought to be due to an enhancement of the hydrogen diffusivity through the oxidation layer. As a result, a low cobalt or manganese content in MmB{sub 5+x} alloys is found to be beneficial for the hydrogen desorption kinetics in both processes. (author)

  3. 重庆地区主要森林类型的空气负离子水平及其评价1)%Air Anions Content and Its Evaluation for Main Forest Types in Chongqing

    Institute of Scientific and Technical Information of China (English)

    王轶浩; 刘访兵; 周小舟; 刘茜; 李彬

    2014-01-01

    With AIC1000 portable air anions tester, the air anion concentration of six main forest types had been measured in 41 monitoring plots of Chongqing in 2012.All forest types significantly can improve air anion content (Pdeciduous broad-leaved forest>evergreen broad-leaved forest>coniferous forest>bamboo forest>mixed conifer-broadleaved forest>CK(Jiefangbei Business District).For evergreen broad-leaved forest and mixed conifer forest, the air anions content in sunny day is higher than that in cloudy day and rain day (P0.05).Air anions of every forest types presents an obviously seasonal variation (P<0.01).The air anions content is the most in spring for mixed conifer-broadleaved forest, evergreen broad-leaved forest and mixed conifer forest, but it is the most in autumn for deciduous broad-leaved forest.Except bamboo forest and mixed conifer forest, air anions of other forest types are the least in winter.The air anions content mainly located in the grade of V level ( 400-1 000 air anions/cm-3 ) in the monitoring spots, and the air quality of Simian Mountains Nature Reserve is the best in all monitoring spots.%利用便携式空气负离子测定仪( AIC1000),对重庆地区6种主要森林类型的41个监测点进行为期1 a的空气负离子监测和研究。结果表明:各森林类型均能显著提高空气负离子水平(P<0.01),从大到小依次为针叶混交林、落叶阔叶林、常绿阔叶林、针叶纯林、竹林、针阔混交林、对照(解放碑商务区);常绿阔叶林和针叶混交林在晴天时的空气负离子水平显著高于阴天和雨天的(P<0.01),而落叶阔叶林却相反;天气阴晴对其它森林类型的空气负离子影响则不显著(P>0.05)。各森林类型的空气负离子呈明显的季节变化(P<0.01),针阔混交林、常绿阔叶林和针叶混交林均以春季最大,落叶阔叶林则以秋季最大;除竹林和针叶混交林外,其它森

  4. Multiple sparse volumetric priors for distributed EEG source reconstruction.

    Science.gov (United States)

    Strobbe, Gregor; van Mierlo, Pieter; De Vos, Maarten; Mijović, Bogdan; Hallez, Hans; Van Huffel, Sabine; López, José David; Vandenberghe, Stefaan

    2014-10-15

    We revisit the multiple sparse priors (MSP) algorithm implemented in the statistical parametric mapping software (SPM) for distributed EEG source reconstruction (Friston et al., 2008). In the present implementation, multiple cortical patches are introduced as source priors based on a dipole source space restricted to a cortical surface mesh. In this note, we present a technique to construct volumetric cortical regions to introduce as source priors by restricting the dipole source space to a segmented gray matter layer and using a region growing approach. This extension allows to reconstruct brain structures besides the cortical surface and facilitates the use of more realistic volumetric head models including more layers, such as cerebrospinal fluid (CSF), compared to the standard 3-layered scalp-skull-brain head models. We illustrated the technique with ERP data and anatomical MR images in 12 subjects. Based on the segmented gray matter for each of the subjects, cortical regions were created and introduced as source priors for MSP-inversion assuming two types of head models. The standard 3-layered scalp-skull-brain head models and extended 4-layered head models including CSF. We compared these models with the current implementation by assessing the free energy corresponding with each of the reconstructions using Bayesian model selection for group studies. Strong evidence was found in favor of the volumetric MSP approach compared to the MSP approach based on cortical patches for both types of head models. Overall, the strongest evidence was found in favor of the volumetric MSP reconstructions based on the extended head models including CSF. These results were verified by comparing the reconstructed activity. The use of volumetric cortical regions as source priors is a useful complement to the present implementation as it allows to introduce more complex head models and volumetric source priors in future studies.

  5. Volumetric measurements of a spatially growing dust acoustic wave

    Science.gov (United States)

    Williams, Jeremiah D.

    2012-11-01

    In this study, tomographic particle image velocimetry (tomo-PIV) techniques are used to make volumetric measurements of the dust acoustic wave (DAW) in a weakly coupled dusty plasma system in an argon, dc glow discharge plasma. These tomo-PIV measurements provide the first instantaneous volumetric measurement of a naturally occurring propagating DAW. These measurements reveal over the measured volume that the measured wave mode propagates in all three spatial dimensional and exhibits the same spatial growth rate and wavelength in each spatial direction.

  6. Volumetric measurements of a spatially growing dust acoustic wave

    Energy Technology Data Exchange (ETDEWEB)

    Williams, Jeremiah D. [Physics Department, Wittenberg University, Springfield, Ohio 45504 (United States)

    2012-11-15

    In this study, tomographic particle image velocimetry (tomo-PIV) techniques are used to make volumetric measurements of the dust acoustic wave (DAW) in a weakly coupled dusty plasma system in an argon, dc glow discharge plasma. These tomo-PIV measurements provide the first instantaneous volumetric measurement of a naturally occurring propagating DAW. These measurements reveal over the measured volume that the measured wave mode propagates in all three spatial dimensional and exhibits the same spatial growth rate and wavelength in each spatial direction.

  7. Volumetric Pricing of Agricultural Water Supplies: A Case Study

    Science.gov (United States)

    Griffin, Ronald C.; Perry, Gregory M.

    1985-07-01

    Models of water consumption by rice producers are conceptualized and then estimated using cross-sectional time series data obtained from 16 Texas canal operators for the years 1977-1982. Two alternative econometric models demonstrate that both volumetric and flat rate water charges are strongly and inversely related to agricultural water consumption. Nonprice conservation incentives accompanying flat rates are hypothesized to explain the negative correlation of flat rate charges and water consumption. Application of these results suggests that water supply organizations in the sample population converting to volumetric pricing will generally reduce water consumption.

  8. Interrelations between the pollution with sulfur dioxide and the movements of stomata in Pelargonium X hortorum: effect of the relative humidity and the air content in carbon dioxide

    Energy Technology Data Exchange (ETDEWEB)

    Bonte, J.; Louguet, P.

    1975-01-01

    The 10/sup -6/ (V/V) concentration of sulphur dioxide, maintained during a sufficient time, causes necrosis on the Pelargonium X hortorum leaves, the importance of which is related to the initial degree of stomatal opening. At light, exposure to SO/sub 2/ is followed by a temporary stomatal closing in dry as in moist air. Nevertheless, damages are greatly enhanced in moist air because the rate of stomatal closing is much slower. If SO/sub 2/ is given in darkness to stomata opened in air without CO/sub 2/, the closing reaction is also observed. At light the sensitivity of the leaves to pollution is greatly increased without CO/sub 2/. The authors consider the possible ways of SO/sub 2/ action upon the mechanisms of stomatal movement and discuss the hypothesis of the protecting role of CO/sub 2/.

  9. Experimental Study of Air-Lift Pumps Characteristics

    Directory of Open Access Journals (Sweden)

    Naji F. Al-Saqer

    2014-03-01

    Full Text Available The mean aim of this work is to study the Air-lift pumps characteristics according to design parameters such as the percentage of the distance between throat section and nozzle and the driving air pressure, suction head and also study the effect of each parameter on the air lift pump characteristics in order to have a better performance of such pump under various conditions. A certain geometry for air-lift pump designed and manufactured. The experiments show that there must be careful in increasing the suction head, and a balance must be considered between the suction head and the driving air volumetric flow rate. While the effect of increasing air pressure will stop at certain maximum of the ratio of the volumetric flow rate of water and air that is any increase in air pressure will meet no change ratio of the volumetric flow rate of water and air, While Increasing S/Dth will leads to decrease in the percentage of ratio of the volumetric flow rate of water and air because the optimum S/Dth so that at this value we will have the best performance and any other values for S/Dth the percentage of ratio of the volumetric flow rate of water and air will decreases , but this effect is not so clear and it could be neglected. The pump performance is not so sensitive with the change of S/Dth after a certain value, this information will help in the use of the air-lift pump in several applications using the predetermined operating conditions.

  10. Identification of the heat transfer coefficient over the external area of a finned tubes heat exchanger with respect to the moisture content of the air without condensation; Identification du coefficient de transfert thermique sur la surface externe d`un echangeur de chaleur a tubes et ailettes planes en fonction de l`humidite de l`air, en l`absence de condensation

    Energy Technology Data Exchange (ETDEWEB)

    Benelmir, R.; Khalfi, M.; Feidt, M. [Nancy-1 Univ. Henri-Poincare, 54 - Vandoeuvre-les-Nancy (France). Lab. d`energetique et de mecanique theorique et appliquee

    1997-04-01

    The following, which is rather oriented towards experimentation, shows the influence of the humidity content of air on heat transfer. This first article concerns heat transfer between, the external fluid (moist air) and the internal fluid (water containing glycol, whose thermal behavior inside circular tubes is well-known) in a heat exchanger of the same type as those used in automotive air conditioning (horizontal copper tubes and plane aluminium fins), in the absence of condensation. The most difficult part of this experimental work is the measurement and control of the air humidity, since one has to make sure that the measurement in certainties are not significant compared to the precision of the calculation of the heat transfer coefficient. The conclusion is that, for this type of exchanger, the heat transfer coefficient decreases with air humidity in the absence of condensation (dry wall). Some correlations have been developed with respect to the relative air humidity. An analog experimental investigation, but this time carried out in the presence of condensation (partially or completely wetted wall), is about to be completed; the obtained results will be communicated later on. (authors) 15 refs.

  11. Space-Time Transfinite Interpolation of Volumetric Material Properties.

    Science.gov (United States)

    Sanchez, Mathieu; Fryazinov, Oleg; Adzhiev, Valery; Comninos, Peter; Pasko, Alexander

    2015-02-01

    The paper presents a novel technique based on extension of a general mathematical method of transfinite interpolation to solve an actual problem in the context of a heterogeneous volume modelling area. It deals with time-dependent changes to the volumetric material properties (material density, colour, and others) as a transformation of the volumetric material distributions in space-time accompanying geometric shape transformations such as metamorphosis. The main idea is to represent the geometry of both objects by scalar fields with distance properties, to establish in a higher-dimensional space a time gap during which the geometric transformation takes place, and to use these scalar fields to apply the new space-time transfinite interpolation to volumetric material attributes within this time gap. The proposed solution is analytical in its nature, does not require heavy numerical computations and can be used in real-time applications. Applications of this technique also include texturing and displacement mapping of time-variant surfaces, and parametric design of volumetric microstructures.

  12. In Vivo Real Time Volumetric Synthetic Aperture Ultrasound Imaging

    DEFF Research Database (Denmark)

    Bouzari, Hamed; Rasmussen, Morten Fischer; Brandt, Andreas Hjelm;

    2015-01-01

    Synthetic aperture (SA) imaging can be used to achieve real-time volumetric ultrasound imaging using 2-D array transducers. The sensitivity of SA imaging is improved by maximizing the acoustic output, but one must consider the limitations of an ultrasound system, both technical and biological...

  13. Automatic segmentation of pulmonary segments from volumetric chest CT scans.

    NARCIS (Netherlands)

    Rikxoort, E.M. van; Hoop, B. de; Vorst, S. van de; Prokop, M.; Ginneken, B. van

    2009-01-01

    Automated extraction of pulmonary anatomy provides a foundation for computerized analysis of computed tomography (CT) scans of the chest. A completely automatic method is presented to segment the lungs, lobes and pulmonary segments from volumetric CT chest scans. The method starts with lung segmenta

  14. Volumetric T-spline Construction Using Boolean Operations

    Science.gov (United States)

    2013-07-01

    15213, USA 2 Institute for Computational Engineering and Sciences, The University of Texas at Austin, Austin, TX 78712, USA 3 Department of Civil and...and S. Yau. Volumetric harmonic map. Communications in Information and Systems, 3(3):191–202, 2003. 12. C.A.R. Guerra . Simultaneous untangling and

  15. Volumetric motion quantification by 3D tissue phase mapped CMR

    Directory of Open Access Journals (Sweden)

    Lutz Anja

    2012-10-01

    Full Text Available Abstract Background The objective of this study was the quantification of myocardial motion from 3D tissue phase mapped (TPM CMR. Recent work on myocardial motion quantification by TPM has been focussed on multi-slice 2D acquisitions thus excluding motion information from large regions of the left ventricle. Volumetric motion assessment appears an important next step towards the understanding of the volumetric myocardial motion and hence may further improve diagnosis and treatments in patients with myocardial motion abnormalities. Methods Volumetric motion quantification of the complete left ventricle was performed in 12 healthy volunteers and two patients applying a black-blood 3D TPM sequence. The resulting motion field was analysed regarding motion pattern differences between apical and basal locations as well as for asynchronous motion pattern between different myocardial segments in one or more slices. Motion quantification included velocity, torsion, rotation angle and strain derived parameters. Results All investigated motion quantification parameters could be calculated from the 3D-TPM data. Parameters quantifying hypokinetic or asynchronous motion demonstrated differences between motion impaired and healthy myocardium. Conclusions 3D-TPM enables the gapless volumetric quantification of motion abnormalities of the left ventricle, which can be applied in future application as additional information to provide a more detailed analysis of the left ventricular function.

  16. Video-rate volumetric optical coherence tomography-based microangiography

    Science.gov (United States)

    Baran, Utku; Wei, Wei; Xu, Jingjiang; Qi, Xiaoli; Davis, Wyatt O.; Wang, Ruikang K.

    2016-04-01

    Video-rate volumetric optical coherence tomography (vOCT) is relatively young in the field of OCT imaging but has great potential in biomedical applications. Due to the recent development of the MHz range swept laser sources, vOCT has started to gain attention in the community. Here, we report the first in vivo video-rate volumetric OCT-based microangiography (vOMAG) system by integrating an 18-kHz resonant microelectromechanical system (MEMS) mirror with a 1.6-MHz FDML swept source operating at ˜1.3 μm wavelength. Because the MEMS scanner can offer an effective B-frame rate of 36 kHz, we are able to engineer vOMAG with a video rate up to 25 Hz. This system was utilized for real-time volumetric in vivo visualization of cerebral microvasculature in mice. Moreover, we monitored the blood perfusion dynamics during stimulation within mouse ear in vivo. We also discussed this system's limitations. Prospective MEMS-enabled OCT probes with a real-time volumetric functional imaging capability can have a significant impact on endoscopic imaging and image-guided surgery applications.

  17. Analysis of Changing Swarm Rate using Volumetric Strain

    Science.gov (United States)

    Kumazawa, T.; Ogata, Y.; Kimura, K.; Maeda, K.; Kobayashi, A.

    2015-12-01

    Near the eastern coast of Izu peninsula is an active submarine volcanic region in Japan, where magma intrusions have been observed many times. The forecast of earthquake swarm activities and eruptions are serious concern particularly in nearby hot spring resort areas. It is well known that temporal durations of the swarm activities have been correlated with early volumetric strain changes at a certain observation station of about 20 km distance apart. Therefore the Earthquake Research Committee (2010) investigated some empirical statistical relations to predict sizes of the swarm activity. Here we looked at the background seismicity rate changes during these swarm periods using the non-stationary ETAS model (Kumazawa and Ogata, 2013, 2014), and have found the followings. The modified volumetric strain data, by removing the effect of earth tides, precipitation and coseismic jumps, have significantly higher cross-correlations to the estimated background rates of the ETAS model than to the swarm rate-changes. Specifically, the background seismicity rate synchronizes clearer to the strain change by the lags around a half day. These relations suggest an enhanced prediction of earthquakes in this region using volumetric strain measurements. Hence we propose an extended ETAS model where the background rate is modulated by the volumetric strain data. We have also found that the response function to the strain data can be well approximated by an exponential functions with the same decay rate, but that their intersects are inversely proportional to the distances between the volumetric strain-meter and the onset location of the swarm. Our numerical results by the same proposed model show consistent outcomes for the various major swarms in this region.

  18. Multi-physics analysis of permanent magnet tubular linear motors under severe volumetric and thermal constraints

    Institute of Scientific and Technical Information of China (English)

    李方; 叶佩青; 张辉

    2016-01-01

    Permanent magnet tubular linear motors (TLMs) arranged in multiple rows and multiple columns used for a radiotherapy machine were studied. Due to severe volumetric and thermal constraints, the TLMs were at high risk of overheating. To predict the performance of the TLMs accurately, a multi-physics analysis approach was proposed. Specifically, it considered the coupling effects amongst the electromagnetic and the thermal models of the TLMs, as well as the fluid model of the surrounding air. To reduce computation cost, both the electromagnetic and the thermal models were based on lumped-parameter methods. Only a minimum set of numerical computation (computational fluid dynamics, CFD) was performed to model the complex fluid behavior. With the proposed approach, both steady state and transient state temperature distributions, thermal rating and permissible load can be predicted. The validity of this approach is verified through the experiment.

  19. Assessment of capacity sensors for monitoring soil water content in ecological orchards

    Science.gov (United States)

    Patrícia Prazeres Marques, Karina; Horcajo, Daniel; Rodriguez-Sinobas, Leonor

    2014-05-01

    Water is an important element for soil tillage and crop development. Its proper management is essential for the development of plants, by preventing excess or shortage in water application. Soil water content is affected by the soil-water-plant system and its monitoring is a required within a sustainable agriculture framework respectful with the natural environment. Thus, the aim of this study was to evaluate the performance of capacitive sensors in monitoring soil moisture from organic orchards. An experimental text was carried out at the Hydraulics Laboratory of the Agricultural Engineering School in the Polytechnic University of Madrid (Spain). Soil samples were collected within the 0-20 cm depth layers from the university organic orchard. The samples were air dried and subsequently sieved in a 2 mm mesh sieve, removing roots and coarse fractions and keeping the fine soil. The amount of fine soil was calculated from the soil density and the soil samples were compacted to obtain the relative volume that corresponded to their density. The measurements were carried out in dry and in saturated soil and, also in samples where soil was stirring with: 150 cm³, 300 cm³ and 450 cm³ of water. A 1890 ml container was used to hold the fine soil and the soil moisture sensor ECH2O, type 10 HS (Decagon Devices, Inc.) was placed horizontally at 5 cm depth. Soil water readings were recorded on a datalogger Em5b from the same manufacturer. The results showed that the capacitive sensor has a linear response to soil moisture content. Its value was overestimated in comparison to the volumetric values and the largest errors (about 8%) were observed in the soils with high moisture contents. Overall, these results point out that the ECH2O sensor, model 10 HS, could determine with sufficient accuracy the volumetric soil water content from organic orchards although it could be further improved by "in situ" calibration.

  20. Radiological assessment of water treatment processes in a water treatment plant in Saudi Arabia: Water and sludge radium content, radon air concentrations and dose rates

    Energy Technology Data Exchange (ETDEWEB)

    Al-Jaseem, Q.Kh., E-mail: qjassem@kacst.edu.sa [Nuclear Science Research Institute (NSRI), King Abdulaziz City for Science and Technology (KACST), P.O. Box 6086, Riyadh 11442 (Saudi Arabia); Almasoud, Fahad I. [Nuclear Science Research Institute (NSRI), King Abdulaziz City for Science and Technology (KACST), P.O. Box 6086, Riyadh 11442 (Saudi Arabia); Ababneh, Anas M. [Physics Dept., Faculty of Science, Islamic University in Madinah, Al-Madinah, P.O. Box 170 (Saudi Arabia); Al-Hobaib, A.S. [Nuclear Science Research Institute (NSRI), King Abdulaziz City for Science and Technology (KACST), P.O. Box 6086, Riyadh 11442 (Saudi Arabia)

    2016-09-01

    There is an increase demand for clean water sources in Saudi Arabia and, yet, renewable water resources are very limited. This has forced the authorities to explore deep groundwater which is known to contain large concentrations of radionuclides, mainly radium isotopes. Lately, there has been an increase in the number of water treatment plants (WTPs) around the country. In this study, a radiological assessment of a WTP in Saudi Arabia was performed. Raw water was found to have total radium activity of 0.23 Bq/L, which exceeds the international limit of 0.185 Bq/L (5 pCi/L). The WTP investigated uses three stages of treatment: flocculation/sedimentation, sand filtration and reverse osmosis. The radium removal efficiency was evaluated for each stage and the respective values were 33%, 22% and 98%. Moreover, the activity of radium in the solid waste generated from the WTP in the sedimentation and sand filtrations stages were measured and found to be 4490 and 6750 Bq/kg, respectively, which exceed the national limit of 1000 Bq/kg for radioactive waste. A radiological assessment of the air inside the WTP was also performed by measuring the radon concentrations and dose rates and were found in the ranges of 2–18 Bq/m{sup 3} and 70–1000 nSv/h, respectively. The annual effective dose was calculated and the average values was found to be 0.3 mSv which is below the 1 mSv limit. - Highlights: • Radiological assessment of groundwater treatment plant was performed. • Radium Removal efficiency was calculated for different stages during water treatment. • Radium concentrations in sludge were measured and found to exceed the national limit for radioactive waste. • Air radon concentrations and dose rates were monitored in the water treatment plant. • The Reverse Osmosis (RO) unit was found to record the highest air radon concentrations and dose rates.

  1. Pulse sequence for dynamic volumetric imaging of hyperpolarized metabolic products

    Science.gov (United States)

    Cunningham, Charles H.; Chen, Albert P.; Lustig, Michael; Hargreaves, Brian A.; Lupo, Janine; Xu, Duan; Kurhanewicz, John; Hurd, Ralph E.; Pauly, John M.; Nelson, Sarah J.; Vigneron, Daniel B.

    2008-07-01

    Dynamic nuclear polarization and dissolution of a 13C-labeled substrate enables the dynamic imaging of cellular metabolism. Spectroscopic information is typically acquired, making the acquisition of dynamic volumetric data a challenge. To enable rapid volumetric imaging, a spectral-spatial excitation pulse was designed to excite a single line of the carbon spectrum. With only a single resonance present in the signal, an echo-planar readout trajectory could be used to resolve spatial information, giving full volume coverage of 32 × 32 × 16 voxels every 3.5 s. This high frame rate was used to measure the different lactate dynamics in different tissues in a normal rat model and a mouse model of prostate cancer.

  2. Nonrigid registration of volumetric images using ranked order statistics

    DEFF Research Database (Denmark)

    Tennakoon, Ruwan; Bab-Hadiashar, Alireza; Cao, Zhenwei

    2014-01-01

    Non-rigid image registration techniques using intensity based similarity measures are widely used in medical imaging applications. Due to high computational complexities of these techniques, particularly for volumetric images, finding appropriate registration methods to both reduce the computation...... burden and increase the registration accuracy has become an intensive area of research. In this paper we propose a fast and accurate non-rigid registration method for intra-modality volumetric images. Our approach exploits the information provided by an order statistics based segmentation method, to find...... the important regions for registration and use an appropriate sampling scheme to target those areas and reduce the registration computation time. A unique advantage of the proposed method is its ability to identify the point of diminishing returns and stop the registration process. Our experiments...

  3. Volumetric characterization of delamination fields via angle longitudinal wave ultrasound

    Science.gov (United States)

    Wertz, John; Wallentine, Sarah; Welter, John; Dierken, Josiah; Aldrin, John

    2017-02-01

    The volumetric characterization of delaminations necessarily precedes rigorous composite damage progression modeling. Yet, inspection of composite structures for subsurface damage remains largely focused on detection, resulting in a capability gap. In response to this need, angle longitudinal wave ultrasound was employed to characterize a composite surrogate containing a simulated three-dimensional delamination field with distinct regions of occluded features (shadow regions). Simple analytical models of the specimen were developed to guide subsequent experimentation through identification of optimal scanning parameters. The ensuing experiments provided visual evidence of the complete delamination field, including indications of features within the shadow regions. The results of this study demonstrate proof-of-principle for the use of angle longitudinal wave ultrasonic inspection for volumetric characterization of three-dimensional delamination fields. Furthermore, the techniques developed herein form the foundation of succeeding efforts to characterize impact delaminations within inhomogeneous laminar materials such as polymer matrix composites.

  4. Magnetic Resonance Image Segmentation and its Volumetric Measurement

    Directory of Open Access Journals (Sweden)

    Rahul R. Ambalkar

    2013-02-01

    Full Text Available Image processing techniques make it possible to extract meaningful information from medical images. Magnetic resonance (MR imaging has been widely applied in biological research and diagnostics because of its excellent soft tissue contrast, non-invasive character, high spatial resolution and easy slice selection at any orientation. The MRI-based brain volumetric is concerned with the analysis of volumes and shapes of the structural components of the human brain. It also provides a criterion, by which we recognize the presence of degenerative diseases and characterize their rates of progression to make the diagnosis and treatments as a easy task. In this paper we have proposed an automated method for volumetric measurement of Magnetic Resonance Imaging and used Self Organized Map (SOM clustering method for their segmentations. We have used the MRI data set of 61 slices of 256×256 pixels in DICOM standard format

  5. Two-dimensional random arrays for real time volumetric imaging

    DEFF Research Database (Denmark)

    Davidsen, Richard E.; Jensen, Jørgen Arendt; Smith, Stephen W.

    1994-01-01

    Two-dimensional arrays are necessary for a variety of ultrasonic imaging techniques, including elevation focusing, 2-D phase aberration correction, and real time volumetric imaging. In order to reduce system cost and complexity, sparse 2-D arrays have been considered with element geometries...... real time volumetric imaging system, which employs a wide transmit beam and receive mode parallel processing to increase image frame rate. Depth-of-field comparisons were made from simulated on-axis and off-axis beamplots at ranges from 30 to 160 mm for both coaxial and offset transmit and receive...... selected ad hoc, by algorithm, or by random process. Two random sparse array geometries and a sparse array with a Mills cross receive pattern were simulated and compared to a fully sampled aperture with the same overall dimensions. The sparse arrays were designed to the constraints of the Duke University...

  6. In Vivo Real Time Volumetric Synthetic Aperture Ultrasound Imaging

    DEFF Research Database (Denmark)

    Bouzari, Hamed; Rasmussen, Morten Fischer; Brandt, Andreas Hjelm

    2015-01-01

    . This paper investigates the in vivo applicability and sensitivity of volumetric SA imaging. Utilizing the transmit events to generate a set of virtual point sources, a frame rate of 25 Hz for a 90° x 90° field-of-view was achieved. Data were obtained using a 3.5 MHz 32 x 32 elements 2-D phased array......Synthetic aperture (SA) imaging can be used to achieve real-time volumetric ultrasound imaging using 2-D array transducers. The sensitivity of SA imaging is improved by maximizing the acoustic output, but one must consider the limitations of an ultrasound system, both technical and biological...... transducer connected to the experimental scanner (SARUS). Proper scaling is applied to the excitation signal such that intensity levels are in compliance with the U.S. Food and Drug Administration regulations for in vivo ultrasound imaging. The measured Mechanical Index and spatial-peak- temporal...

  7. COMPARISON OF VOLUMETRIC REGISTRATION ALGORITHMS FOR TENSOR-BASED MORPHOMETRY

    Science.gov (United States)

    Villalon, Julio; Joshi, Anand A.; Toga, Arthur W.; Thompson, Paul M.

    2015-01-01

    Nonlinear registration of brain MRI scans is often used to quantify morphological differences associated with disease or genetic factors. Recently, surface-guided fully 3D volumetric registrations have been developed that combine intensity-guided volume registrations with cortical surface constraints. In this paper, we compare one such algorithm to two popular high-dimensional volumetric registration methods: large-deformation viscous fluid registration, formulated in a Riemannian framework, and the diffeomorphic “Demons” algorithm. We performed an objective morphometric comparison, by using a large MRI dataset from 340 young adult twin subjects to examine 3D patterns of correlations in anatomical volumes. Surface-constrained volume registration gave greater effect sizes for detecting morphometric associations near the cortex, while the other two approaches gave greater effects sizes subcortically. These findings suggest novel ways to combine the advantages of multiple methods in the future. PMID:26925198

  8. Volumetric 3D display using a DLP projection engine

    Science.gov (United States)

    Geng, Jason

    2012-03-01

    In this article, we describe a volumetric 3D display system based on the high speed DLPTM (Digital Light Processing) projection engine. Existing two-dimensional (2D) flat screen displays often lead to ambiguity and confusion in high-dimensional data/graphics presentation due to lack of true depth cues. Even with the help of powerful 3D rendering software, three-dimensional (3D) objects displayed on a 2D flat screen may still fail to provide spatial relationship or depth information correctly and effectively. Essentially, 2D displays have to rely upon capability of human brain to piece together a 3D representation from 2D images. Despite the impressive mental capability of human visual system, its visual perception is not reliable if certain depth cues are missing. In contrast, volumetric 3D display technologies to be discussed in this article are capable of displaying 3D volumetric images in true 3D space. Each "voxel" on a 3D image (analogous to a pixel in 2D image) locates physically at the spatial position where it is supposed to be, and emits light from that position toward omni-directions to form a real 3D image in 3D space. Such a volumetric 3D display provides both physiological depth cues and psychological depth cues to human visual system to truthfully perceive 3D objects. It yields a realistic spatial representation of 3D objects and simplifies our understanding to the complexity of 3D objects and spatial relationship among them.

  9. Using surface heave to estimate reservoir volumetric strain

    Energy Technology Data Exchange (ETDEWEB)

    Nanayakkara, A.S.; Wong, R.C.K. [Calgary Univ., AB (Canada)

    2008-07-01

    This paper presented a newly developed numerical tool for estimating reservoir volumetric strain distribution using surface vertical displacements and solving an inverse problem. Waterflooding, steam injection, carbon dioxide sequestration and aquifer storage recovery are among the subsurface injection operations that are responsible for reservoir dilations which propagate to the surrounding formations and extend to the surface resulting in surface heaves. Global positioning systems and surface tiltmeters are often used to measure the characteristics of these surface heaves and to derive valuable information regarding reservoir deformation and flow characteristics. In this study, Tikhonov regularization techniques were adopted to solve the ill-posed inversion problem commonly found in standard inversion techniques such as Gaussian elimination and least squares methods. Reservoir permeability was then estimated by inverting the volumetric strain distribution. Results of the newly developed numerical tool were compared with results from fully-coupled finite element simulation of fluid injection problems. The reservoir volumetric strain distribution was successfully estimated along with an approximate value for reservoir permeability.

  10. Volumetric Light-field Encryption at the Microscopic Scale

    Science.gov (United States)

    Li, Haoyu; Guo, Changliang; Muniraj, Inbarasan; Schroeder, Bryce C.; Sheridan, John T.; Jia, Shu

    2017-01-01

    We report a light-field based method that allows the optical encryption of three-dimensional (3D) volumetric information at the microscopic scale in a single 2D light-field image. The system consists of a microlens array and an array of random phase/amplitude masks. The method utilizes a wave optics model to account for the dominant diffraction effect at this new scale, and the system point-spread function (PSF) serves as the key for encryption and decryption. We successfully developed and demonstrated a deconvolution algorithm to retrieve both spatially multiplexed discrete data and continuous volumetric data from 2D light-field images. Showing that the method is practical for data transmission and storage, we obtained a faithful reconstruction of the 3D volumetric information from a digital copy of the encrypted light-field image. The method represents a new level of optical encryption, paving the way for broad industrial and biomedical applications in processing and securing 3D data at the microscopic scale.

  11. Volumetric Light-field Encryption at the Microscopic Scale

    Science.gov (United States)

    Li, Haoyu; Guo, Changliang; Muniraj, Inbarasan; Schroeder, Bryce C.; Sheridan, John T.; Jia, Shu

    2017-01-01

    We report a light-field based method that allows the optical encryption of three-dimensional (3D) volumetric information at the microscopic scale in a single 2D light-field image. The system consists of a microlens array and an array of random phase/amplitude masks. The method utilizes a wave optics model to account for the dominant diffraction effect at this new scale, and the system point-spread function (PSF) serves as the key for encryption and decryption. We successfully developed and demonstrated a deconvolution algorithm to retrieve both spatially multiplexed discrete data and continuous volumetric data from 2D light-field images. Showing that the method is practical for data transmission and storage, we obtained a faithful reconstruction of the 3D volumetric information from a digital copy of the encrypted light-field image. The method represents a new level of optical encryption, paving the way for broad industrial and biomedical applications in processing and securing 3D data at the microscopic scale. PMID:28059149

  12. Volumetric Light-field Encryption at the Microscopic Scale

    CERN Document Server

    Li, Haoyu; Muniraj, Inbarasan; Schroeder, Bryce C; Sheridan, John T; Jia, Shu

    2016-01-01

    We report a light-field based method that allows the optical encryption of three-dimensional (3D) volumetric information at the microscopic scale in a single 2D light-field image. The system consists of a microlens array and an array of random phase/amplitude masks. The method utilizes a wave optics model to account for the dominant diffraction effect at this new scale, and the system point-spread function (PSF) serves as the key for encryption and decryption. We successfully developed and demonstrated a deconvolution algorithm to retrieve spatially multiplexed discrete and continuous volumetric data from 2D light-field images. Showing that the method is practical for data transmission and storage, we obtained a faithful reconstruction of the 3D volumetric information from a digital copy of the encrypted light-field image. The method represents a new level of optical encryption, paving the way for broad industrial and biomedical applications in processing and securing 3D data at the microscopic scale.

  13. Volumetric Light-field Encryption at the Microscopic Scale.

    Science.gov (United States)

    Li, Haoyu; Guo, Changliang; Muniraj, Inbarasan; Schroeder, Bryce C; Sheridan, John T; Jia, Shu

    2017-01-06

    We report a light-field based method that allows the optical encryption of three-dimensional (3D) volumetric information at the microscopic scale in a single 2D light-field image. The system consists of a microlens array and an array of random phase/amplitude masks. The method utilizes a wave optics model to account for the dominant diffraction effect at this new scale, and the system point-spread function (PSF) serves as the key for encryption and decryption. We successfully developed and demonstrated a deconvolution algorithm to retrieve both spatially multiplexed discrete data and continuous volumetric data from 2D light-field images. Showing that the method is practical for data transmission and storage, we obtained a faithful reconstruction of the 3D volumetric information from a digital copy of the encrypted light-field image. The method represents a new level of optical encryption, paving the way for broad industrial and biomedical applications in processing and securing 3D data at the microscopic scale.

  14. 气体射流冲击干燥含水率在线监控系统设计%Design of online monitoring system for material moisture content in air-impingement drying process

    Institute of Scientific and Technical Information of China (English)

    王栋; 林海; 肖红伟; 刘嫣红; 巨浩羽; 代建武; 高振江

    2014-01-01

    针对气体射流冲击干燥过程中自动称量受风速、设备运行振动、干燥温度等因素影响的问题,设计了新型干燥设备监控系统,实现了干燥过程中物料质量及含水率的自动获取、即时查看及数据显示和存储。系统通过“停机-稳定-称量-启动”自动称量流程及分温度段分载荷区间线性化校准等方案,有效保证了自动称量精度,通过将从机控制器的运行状态纳入到系统运行逻辑判断中,保证了系统长期运行的可靠性和安全性。系统称量量程0~2000 g,最小分度值1 g。试验表明:自动称量系统相对误差小于0.7%,含水率(湿基)分析误差在±0.9%范围内,满足了干燥过程中在线物料质量及含水率监测需要。该系统为多种物料的干燥进程判断及产品质量保证提供了自动化监控平台。%Moisture content is an important quality index of drying products, which can be obtained by automatic weighing and analyzing its mass in the drying process. Compared with other moisture content measurement technology, the automatic weighing method has good versatility, high accuracy, and simple architecture. Relative humidity of drying air has significant effect on drying kinetics and product quality, while, for interior weighing devices, the humidity of hot air can easily be kept stable during drying process. In order to mitigate the effects of air velocity, equipment operating vibration, drying temperature, and other factors on the interior automatic weighing system of air-impingement drying, a new drying monitoring system based on Modbus communication protocol and RS 485 bus was designed. This system consists of five parts:an HMI (human machine interface) as master, a weighing system, a drying temperature control system, humidity control system, and air velocity control system. This paper mainly focuses on the measurement of material mass and moisture content. For the hardware of weighing

  15. Cold-batter mincing of hot-boned and crust-frozen air-chilled turkey breast allows for reduced sodium content in protein gels.

    Science.gov (United States)

    Lee, H C; Medellin-Lopez, M; Singh, P; Sansawat, T; Chin, K B; Kang, I

    2014-09-01

    The purpose of this research was to evaluate sodium reduction in the protein gels that were prepared with turkey breasts after hot boning (HB), quarter (¼) sectioning, crust-frozen air-chilling (CFAC), and cold temperature mincing. For each of 4 replications, 36 turkeys were slaughtered and eviscerated. One-half of the carcasses were randomly assigned to water immersion chilling for chill boning (CB), whereas the remaining carcasses were immediately HB and quarter-sectioned/crust-frozen air-chilled (HB-¼CFAC) in a freezing room (-12°C, 1.0 m/s). After deboning, CB fillets were conventionally minced, whereas HB-¼CFAC fillets were cold minced up to 27 min with 1 or 2% salt. From the beginning of mincing, the batter temperatures of HB-¼CFAC were lower (P 0.05) from the pH of CB batters, except for the 1% salt HB-¼CFAC batter after 15 min of mincing. The pattern of pH was not changed when the batters were stored overnight. The protein of 2% salt HB-¼CFAC fillets was more extractable (P < 0.05) than that of CB fillets at 9, 12, 18, and 24 min. Similarly, the protein of 1% salt HB-¼CFAC fillets was more extractable (P < 0.05) than that of CB fillets from 12 min. Stress values of 2% salt HB-¼CFAC gels were higher (P < 0.05) than those of 1 and 2% salt CB gels, with intermediate values for 1% salt HB-¼CFAC gels. In the scanning electron microscope image, prerigor batter appears to have more open space, less protein aggregation, and more protein-coated fat particles than those of postrigor batters. Based on these results, the combination of HB-¼CFAC and cold-batter-mincing technologies appear to improve protein functionality and sodium reduction capacity. © 2014 Poultry Science Association Inc.

  16. Predicting Soil-Water Characteristics from Volumetric Contents of Pore-Size Analogue Particle Fractions

    DEFF Research Database (Denmark)

    Naveed, Muhammad; Møldrup, Per; Tuller, Markus;

    F value. Hereby, the Xw*-model implicitly assumes that a given particle size fraction creates an analogue pore size fraction and, also, is based on the validity of the well-known capillary law equation relating equivalent drained pore size to the soil-water matric potential. The Xw*-model was found...

  17. Borehole Volumetric Strainmeters Detect Very Long-period Ocean Level Changes in Tokai Area

    Science.gov (United States)

    Takanami, T.; Linde, A. T.; Sacks, S. I.; Kitagawa, G.; Hirata, N.; Rydelek, P. A.

    2015-12-01

    We detected a clear very long-period strain signal with a predominant period of about 2 months in the data from Sacks-Evertson borehole volumetric strainmeters. These have been operated by the Japan Meteorological Agency (JMA) since 1976 in Tokai area, Japan, the area of an expected Tokai eartquake. Earth's surface is always influenced by natural force such as earth tide, air pressure, and precipitation as well as by human induced sources. In order to decompose into their components in the maximum likelihood estimation, state-space modeling (Takanami et al., 2013) is applied to the observed time series data for 15 months before and after the earthquake M6.5 that occurred on 11th August 2009 in Suruga Bay. In the analysis, the strain data are decomposed into trend, air pressure, earth tide, precipitation effects and observation noise. Clear long-period strain signals are seen in the normalized trend component time series. Time series data from JMA tide gages around Suruga Bay are similarly decomposed. Then spectral analyses are applied to the trend components for the same time interval. Comparison of amplitude peaks in spectra for both data sets show all have a peak at period of about 1464 hours. Thus strain changes may be influenced by very long-period ocean level changes; it is necessary to consider this possibility before attributing tectonic significance to such variations.

  18. Volumetric CT-images improve testing of radiological image interpretation skills

    Energy Technology Data Exchange (ETDEWEB)

    Ravesloot, Cécile J., E-mail: C.J.Ravesloot@umcutrecht.nl [Radiology Department at University Medical Center Utrecht, Heidelberglaan 100, 3508 GA Utrecht, Room E01.132 (Netherlands); Schaaf, Marieke F. van der, E-mail: M.F.vanderSchaaf@uu.nl [Department of Pedagogical and Educational Sciences at Utrecht University, Heidelberglaan 1, 3584 CS Utrecht (Netherlands); Schaik, Jan P.J. van, E-mail: J.P.J.vanSchaik@umcutrecht.nl [Radiology Department at University Medical Center Utrecht, Heidelberglaan 100, 3508 GA Utrecht, Room E01.132 (Netherlands); Cate, Olle Th.J. ten, E-mail: T.J.tenCate@umcutrecht.nl [Center for Research and Development of Education at University Medical Center Utrecht, Heidelberglaan 100, 3508 GA Utrecht (Netherlands); Gijp, Anouk van der, E-mail: A.vanderGijp-2@umcutrecht.nl [Radiology Department at University Medical Center Utrecht, Heidelberglaan 100, 3508 GA Utrecht, Room E01.132 (Netherlands); Mol, Christian P., E-mail: C.Mol@umcutrecht.nl [Image Sciences Institute at University Medical Center Utrecht, Heidelberglaan 100, 3508 GA Utrecht (Netherlands); Vincken, Koen L., E-mail: K.Vincken@umcutrecht.nl [Image Sciences Institute at University Medical Center Utrecht, Heidelberglaan 100, 3508 GA Utrecht (Netherlands)

    2015-05-15

    Rationale and objectives: Current radiology practice increasingly involves interpretation of volumetric data sets. In contrast, most radiology tests still contain only 2D images. We introduced a new testing tool that allows for stack viewing of volumetric images in our undergraduate radiology program. We hypothesized that tests with volumetric CT-images enhance test quality, in comparison with traditional completely 2D image-based tests, because they might better reflect required skills for clinical practice. Materials and methods: Two groups of medical students (n = 139; n = 143), trained with 2D and volumetric CT-images, took a digital radiology test in two versions (A and B), each containing both 2D and volumetric CT-image questions. In a questionnaire, they were asked to comment on the representativeness for clinical practice, difficulty and user-friendliness of the test questions and testing program. Students’ test scores and reliabilities, measured with Cronbach's alpha, of 2D and volumetric CT-image tests were compared. Results: Estimated reliabilities (Cronbach's alphas) were higher for volumetric CT-image scores (version A: .51 and version B: .54), than for 2D CT-image scores (version A: .24 and version B: .37). Participants found volumetric CT-image tests more representative of clinical practice, and considered them to be less difficult than volumetric CT-image questions. However, in one version (A), volumetric CT-image scores (M 80.9, SD 14.8) were significantly lower than 2D CT-image scores (M 88.4, SD 10.4) (p < .001). The volumetric CT-image testing program was considered user-friendly. Conclusion: This study shows that volumetric image questions can be successfully integrated in students’ radiology testing. Results suggests that the inclusion of volumetric CT-images might improve the quality of radiology tests by positively impacting perceived representativeness for clinical practice and increasing reliability of the test.

  19. Calidad del aire interior

    Science.gov (United States)

    This web site will educate the public about indoor environmental issues including health risks and means by which human exposures can be reduced. Content on this site will be focused on Spanish translated resources for information about indoor air quality.

  20. Gravimetric and volumetric determination of the purity of electrolytically refined silver and the produced silver nitrate

    Directory of Open Access Journals (Sweden)

    Ačanski Marijana M.

    2007-01-01

    purity of electrolytically refined silver obtained volumetrically, according to Volhard, was 99.49%. The results suggest that the purity of electrolytically refined silver was higher than 99%. After all of these determinations, the purity of electrolytically refined silver was examined by atomic absorption spectrometry and the results confirmed that the purity of electrolytically refined silver was 99.99%. Electrolytically refined silver contained other metals: Mn, Cu, Fe, Zn, Pb, Cd, and the contents of these metals were: 1.15 ppm; 0.75 ppm; 0.65 ppm; 1.82 ppm; < 0.07 ppm and < 0.01 ppm, respectively.

  1. Radiological assessment of water treatment processes in a water treatment plant in Saudi Arabia: Water and sludge radium content, radon air concentrations and dose rates.

    Science.gov (United States)

    Al-Jaseem, Q Kh; Almasoud, Fahad I; Ababneh, Anas M; Al-Hobaib, A S

    2016-09-01

    There is an increase demand for clean water sources in Saudi Arabia and, yet, renewable water resources are very limited. This has forced the authorities to explore deep groundwater which is known to contain large concentrations of radionuclides, mainly radium isotopes. Lately, there has been an increase in the number of water treatment plants (WTPs) around the country. In this study, a radiological assessment of a WTP in Saudi Arabia was performed. Raw water was found to have total radium activity of 0.23Bq/L, which exceeds the international limit of 0.185Bq/L (5pCi/L). The WTP investigated uses three stages of treatment: flocculation/sedimentation, sand filtration and reverse osmosis. The radium removal efficiency was evaluated for each stage and the respective values were 33%, 22% and 98%. Moreover, the activity of radium in the solid waste generated from the WTP in the sedimentation and sand filtrations stages were measured and found to be 4490 and 6750Bq/kg, respectively, which exceed the national limit of 1000Bq/kg for radioactive waste. A radiological assessment of the air inside the WTP was also performed by measuring the radon concentrations and dose rates and were found in the ranges of 2-18Bq/m(3) and 70-1000nSv/h, respectively. The annual effective dose was calculated and the average values was found to be 0.3mSv which is below the 1mSv limit.

  2. Personalized heterogeneous deformable model for fast volumetric registration.

    Science.gov (United States)

    Si, Weixin; Liao, Xiangyun; Wang, Qiong; Heng, Pheng Ann

    2017-02-20

    Biomechanical deformable volumetric registration can help improve safety of surgical interventions by ensuring the operations are extremely precise. However, this technique has been limited by the accuracy and the computational efficiency of patient-specific modeling. This study presents a tissue-tissue coupling strategy based on penalty method to model the heterogeneous behavior of deformable body, and estimate the personalized tissue-tissue coupling parameters in a data-driven way. Moreover, considering that the computational efficiency of biomechanical model is highly dependent on the mechanical resolution, a practical coarse-to-fine scheme is proposed to increase runtime efficiency. Particularly, a detail enrichment database is established in an offline fashion to represent the mapping relationship between the deformation results of high-resolution hexahedral mesh extracted from the raw medical data and a newly constructed low-resolution hexahedral mesh. At runtime, the mechanical behavior of human organ under interactions is simulated with this low-resolution hexahedral mesh, then the microstructures are synthesized in virtue of the detail enrichment database. The proposed method is validated by volumetric registration in an abdominal phantom compression experiments. Our personalized heterogeneous deformable model can well describe the coupling effects between different tissues of the phantom. Compared with high-resolution heterogeneous deformable model, the low-resolution deformable model with our detail enrichment database can achieve 9.4× faster, and the average target registration error is 3.42 mm, which demonstrates that the proposed method shows better volumetric registration performance than state-of-the-art. Our framework can well balance the precision and efficiency, and has great potential to be adopted in the practical augmented reality image-guided robotic systems.

  3. Volumetric measurements of pulmonary nodules: variability in automated analysis tools

    Science.gov (United States)

    Juluru, Krishna; Kim, Woojin; Boonn, William; King, Tara; Siddiqui, Khan; Siegel, Eliot

    2007-03-01

    Over the past decade, several computerized tools have been developed for detection of lung nodules and for providing volumetric analysis. Incidentally detected lung nodules have traditionally been followed over time by measurements of their axial dimensions on CT scans to ensure stability or document progression. A recently published article by the Fleischner Society offers guidelines on the management of incidentally detected nodules based on size criteria. For this reason, differences in measurements obtained by automated tools from various vendors may have significant implications on management, yet the degree of variability in these measurements is not well understood. The goal of this study is to quantify the differences in nodule maximum diameter and volume among different automated analysis software. Using a dataset of lung scans obtained with both "ultra-low" and conventional doses, we identified a subset of nodules in each of five size-based categories. Using automated analysis tools provided by three different vendors, we obtained size and volumetric measurements on these nodules, and compared these data using descriptive as well as ANOVA and t-test analysis. Results showed significant differences in nodule maximum diameter measurements among the various automated lung nodule analysis tools but no significant differences in nodule volume measurements. These data suggest that when using automated commercial software, volume measurements may be a more reliable marker of tumor progression than maximum diameter. The data also suggest that volumetric nodule measurements may be relatively reproducible among various commercial workstations, in contrast to the variability documented when performing human mark-ups, as is seen in the LIDC (lung imaging database consortium) study.

  4. Volumetric hemispheric ratio as a useful tool in personality psychology.

    Science.gov (United States)

    Montag, Christian; Schoene-Bake, Jan-Christoph; Wagner, Jan; Reuter, Martin; Markett, Sebastian; Weber, Bernd; Quesada, Carlos M

    2013-02-01

    The present study investigates the link between volumetric hemispheric ratios (VHRs) and personality measures in N=267 healthy participants using Eysenck's Personality Inventory-Revised (EPQ-R) and the BIS/BAS scales. A robust association between extraversion and VHRs was observed for gray matter in males but not females. Higher gray matter volume in the left than in the right hemisphere was associated with higher extraversion in males. The results are discussed in the context of positive emotionality and laterality of the human brain.

  5. AN ATTRIBUTION OF CAVITATION RESONANCE: VOLUMETRIC OSCILLATIONS OF CLOUD

    Institute of Scientific and Technical Information of China (English)

    ZUO Zhi-gang; LI Sheng-cai; LIU Shu-hong; LI Shuang; CHEN Hui

    2009-01-01

    In order to further verify the proposed theory of cavitation resonance, as well as to proceed the investigations into microscopic level, a series of studies are being carried out on the Warwick venturi. The analysis of the oscillation characteristics of the cavitation resonance has conclusively verified the macro-mechanism proposed through previous studies on other cavitating flows by the authors. The initial observations using high-speed photographic approach have revealed a new attribution of cavitation resonance. That is, the volumetric oscillation of cavitation cloud is associated with the cavitation resonance, which is a collective behaviour of the bubbles in the cloud.

  6. Synthesis of Volumetric Ring Antenna Array for Terrestrial Coverage Pattern

    Directory of Open Access Journals (Sweden)

    Alberto Reyna

    2014-01-01

    Full Text Available This paper presents a synthesis of a volumetric ring antenna array for a terrestrial coverage pattern. This synthesis regards the spacing among the rings on the planes X-Y, the positions of the rings on the plane X-Z, and uniform and concentric excitations. The optimization is carried out by implementing the particle swarm optimization. The synthesis is compared with previous designs by resulting with proper performance of this geometry to provide an accurate coverage to be applied in satellite applications with a maximum reduction of the antenna hardware as well as the side lobe level reduction.

  7. Synthesis of Volumetric Ring Antenna Array for Terrestrial Coverage Pattern

    Science.gov (United States)

    Reyna, Alberto; Panduro, Marco A.; Del Rio Bocio, Carlos

    2014-01-01

    This paper presents a synthesis of a volumetric ring antenna array for a terrestrial coverage pattern. This synthesis regards the spacing among the rings on the planes X-Y, the positions of the rings on the plane X-Z, and uniform and concentric excitations. The optimization is carried out by implementing the particle swarm optimization. The synthesis is compared with previous designs by resulting with proper performance of this geometry to provide an accurate coverage to be applied in satellite applications with a maximum reduction of the antenna hardware as well as the side lobe level reduction. PMID:24701150

  8. Estimation of volumetric breast density for breast cancer risk prediction

    Science.gov (United States)

    Pawluczyk, Olga; Yaffe, Martin J.; Boyd, Norman F.; Jong, Roberta A.

    2000-04-01

    Mammographic density (MD) has been shown to be a strong risk predictor for breast cancer. Compared to subjective assessment by a radiologist, computer-aided analysis of digitized mammograms provides a quantitative and more reproducible method for assessing breast density. However, the current methods of estimating breast density based on the area of bright signal in a mammogram do not reflect the true, volumetric quantity of dense tissue in the breast. A computerized method to estimate the amount of radiographically dense tissue in the overall volume of the breast has been developed to provide an automatic, user-independent tool for breast cancer risk assessment. The procedure for volumetric density estimation consists of first correcting the image for inhomogeneity, then performing a volume density calculation. First, optical sensitometry is used to convert all images to the logarithm of relative exposure (LRE), in order to simplify the image correction operations. The field non-uniformity correction, which takes into account heel effect, inverse square law, path obliquity and intrinsic field and grid non- uniformity is obtained by imaging a spherical section PMMA phantom. The processed LRE image of the phantom is then used as a correction offset for actual mammograms. From information about the thickness and placement of the breast, as well as the parameters of a breast-like calibration step wedge placed in the mammogram, MD of the breast is calculated. Post processing and a simple calibration phantom enable user- independent, reliable and repeatable volumetric estimation of density in breast-equivalent phantoms. Initial results obtained on known density phantoms show the estimation to vary less than 5% in MD from the actual value. This can be compared to estimated mammographic density differences of 30% between the true and non-corrected values. Since a more simplistic breast density measurement based on the projected area has been shown to be a strong indicator

  9. Volumetric 3D Display System with Static Screen

    Science.gov (United States)

    Geng, Jason

    2011-01-01

    Current display technology has relied on flat, 2D screens that cannot truly convey the third dimension of visual information: depth. In contrast to conventional visualization that is primarily based on 2D flat screens, the volumetric 3D display possesses a true 3D display volume, and places physically each 3D voxel in displayed 3D images at the true 3D (x,y,z) spatial position. Each voxel, analogous to a pixel in a 2D image, emits light from that position to form a real 3D image in the eyes of the viewers. Such true volumetric 3D display technology provides both physiological (accommodation, convergence, binocular disparity, and motion parallax) and psychological (image size, linear perspective, shading, brightness, etc.) depth cues to human visual systems to help in the perception of 3D objects. In a volumetric 3D display, viewers can watch the displayed 3D images from a completely 360 view without using any special eyewear. The volumetric 3D display techniques may lead to a quantum leap in information display technology and can dramatically change the ways humans interact with computers, which can lead to significant improvements in the efficiency of learning and knowledge management processes. Within a block of glass, a large amount of tiny dots of voxels are created by using a recently available machining technique called laser subsurface engraving (LSE). The LSE is able to produce tiny physical crack points (as small as 0.05 mm in diameter) at any (x,y,z) location within the cube of transparent material. The crack dots, when illuminated by a light source, scatter the light around and form visible voxels within the 3D volume. The locations of these tiny voxels are strategically determined such that each can be illuminated by a light ray from a high-resolution digital mirror device (DMD) light engine. The distribution of these voxels occupies the full display volume within the static 3D glass screen. This design eliminates any moving screen seen in previous

  10. Floating volumetric image formation using a dihedral corner reflector array device.

    Science.gov (United States)

    Miyazaki, Daisuke; Hirano, Noboru; Maeda, Yuki; Yamamoto, Siori; Mukai, Takaaki; Maekawa, Satoshi

    2013-01-01

    A volumetric display system using an optical imaging device consisting of numerous dihedral corner reflectors placed perpendicular to the surface of a metal plate is proposed. Image formation by the dihedral corner reflector array (DCRA) is free from distortion and focal length. In the proposed volumetric display system, a two-dimensional real image is moved by a mirror scanner to scan a three-dimensional (3D) space. Cross-sectional images of a 3D object are displayed in accordance with the position of the image plane. A volumetric image is observed as a stack of the cross-sectional images. The use of the DCRA brings compact system configuration and volumetric real image generation with very low distortion. An experimental volumetric display system including a DCRA, a galvanometer mirror, and a digital micro-mirror device was constructed to verify the proposed method. A volumetric image consisting of 1024×768×400 voxels was formed by the experimental system.

  11. A new model for estimating subsurface ice content based on combined electrical and seismic data sets

    Directory of Open Access Journals (Sweden)

    C. Hauck

    2011-06-01

    Full Text Available Detailed knowledge of the material properties and internal structures of frozen ground is one of the prerequisites in many permafrost studies. In the absence of direct evidence, such as in-situ borehole measurements, geophysical methods are an increasingly interesting option for obtaining subsurface information on various spatial and temporal scales. The indirect nature of geophysical soundings requires a relation between the measured variables (e.g. electrical resistivity, seismic velocity and the actual subsurface constituents (rock, water, air, ice. In this work, we present a model which provides estimates of the volumetric fractions of these four constituents from tomographic electrical and seismic images. The model is tested using geophysical data sets from two rock glaciers in the Swiss Alps, where ground truth information in form of borehole data is available. First results confirm the applicability of the so-called 4-phase model, which allows to quantify the contributions of ice-, water- and air within permafrost areas as well as detecting solid bedrock. Apart from a similarly thick active layer with enhanced air content for both rock glaciers, the two case studies revealed a heterogeneous distribution of ice and unfrozen water within Muragl rock glacier, where bedrock was detected at depths of 20–25 m, but a comparatively homogeneous ice body with only minor heterogeneities within Murtèl rock glacier.

  12. A new model for quantifying subsurface ice content based on geophysical data sets

    Directory of Open Access Journals (Sweden)

    C. Hauck

    2010-06-01

    Full Text Available Detailed knowledge of the material properties and internal structures of frozen ground is one of the prerequisites in many permafrost studies. In the absence of direct evidence, such as in-situ borehole measurements, geophysical methods are an increasingly interesting option for obtaining subsurface information on various spatial and temporal scales. The indirect nature of geophysical soundings requires a relation between the measured variables (e.g. electrical resistivity, seismic velocity and the actual subsurface constituents (rock, water, air, ice. In this work we present a model, which provides estimates of the volumetric fractions of these four phases from tomographic electrical and seismic images. The model is tested using geophysical data sets from two rock glaciers in the Swiss Alps, where ground truth information in form of borehole data is available. First results confirm the applicability of the so-called 4-phase model, which allows to quantify the contributions of ice-, water- and air within permafrost areas as well as detecting the firm bedrock. Apart from a similarly thick active layer with enhanced air content for both rock glaciers, the two case studies revealed a heterogeneous distribution of ice and unfrozen water within rock glacier Muragl, where bedrock was detected at depths of 20–25 m, but a comparatively homogeneous ice body with only minor heterogeneities within rock glacier Murtèl.

  13. Relating Linear and Volumetric Variables Through Body Scanning to Improve Human Interfaces in Space

    Science.gov (United States)

    Margerum, Sarah E.; Ferrer, Mike A.; Young, Karen S.; Rajulu, Sudhakar

    2010-01-01

    Designing space suits and vehicles for the diverse human population present unique challenges for the methods of traditional anthropometry. Space suits are bulky and allow the operator to shift position within the suit and inhibit the ability to identify body landmarks. Limited suit sizing options also cause variability in fit and performance between similarly sized individuals. Space vehicles are restrictive in volume in both the fit and the ability to collect data. NASA's Anthropometric and Biomechanics Facility (ABF) has utilized 3D scanning to shift from traditional linear anthropometry to explore and examine volumetric capabilities to provide anthropometric solutions for design. Overall, the key goals are to improve the human-system performance and develop new processes to aid in the design and evaluation of space systems. Four case studies are presented that illustrate the shift from purely linear analyses to an augmented volumetric toolset to predict and analyze the human within the space suit and vehicle. The first case study involves the calculation of maximal head volume to estimate total free volume in the helmet for proper air exchange. Traditional linear measurements resulted in an inaccurate representation of the head shape, yet limited data exists for the determination of a large head volume. Steps were first taken to identify and classify a maximum head volume and the resulting comparisons to the estimate are presented in this paper. This study illustrates the gap between linear components of anthropometry and the need for overall volume metrics in order to provide solutions. A second case study examines the overlay of the space suit scans and components onto scanned individuals to quantify fit and clearance to aid in sizing the suit to the individual. Restrictions in space suit size availability present unique challenges to optimally fit the individual within a limited sizing range while maintaining performance. Quantification of the clearance and

  14. Volumetric display containing multiple two-dimensional color motion pictures

    Science.gov (United States)

    Hirayama, R.; Shiraki, A.; Nakayama, H.; Kakue, T.; Shimobaba, T.; Ito, T.

    2014-06-01

    We have developed an algorithm which can record multiple two-dimensional (2-D) gradated projection patterns in a single three-dimensional (3-D) object. Each recorded pattern has the individual projected direction and can only be seen from the direction. The proposed algorithm has two important features: the number of recorded patterns is theoretically infinite and no meaningful pattern can be seen outside of the projected directions. In this paper, we expanded the algorithm to record multiple 2-D projection patterns in color. There are two popular ways of color mixing: additive one and subtractive one. Additive color mixing used to mix light is based on RGB colors and subtractive color mixing used to mix inks is based on CMY colors. We made two coloring methods based on the additive mixing and subtractive mixing. We performed numerical simulations of the coloring methods, and confirmed their effectiveness. We also fabricated two types of volumetric display and applied the proposed algorithm to them. One is a cubic displays constructed by light-emitting diodes (LEDs) in 8×8×8 array. Lighting patterns of LEDs are controlled by a microcomputer board. The other one is made of 7×7 array of threads. Each thread is illuminated by a projector connected with PC. As a result of the implementation, we succeeded in recording multiple 2-D color motion pictures in the volumetric displays. Our algorithm can be applied to digital signage, media art and so forth.

  15. Volumetric three-dimensional display system with rasterization hardware

    Science.gov (United States)

    Favalora, Gregg E.; Dorval, Rick K.; Hall, Deirdre M.; Giovinco, Michael; Napoli, Joshua

    2001-06-01

    An 8-color multiplanar volumetric display is being developed by Actuality Systems, Inc. It will be capable of utilizing an image volume greater than 90 million voxels, which we believe is the greatest utilizable voxel set of any volumetric display constructed to date. The display is designed to be used for molecular visualization, mechanical CAD, e-commerce, entertainment, and medical imaging. As such, it contains a new graphics processing architecture, novel high-performance line- drawing algorithms, and an API similar to a current standard. Three-dimensional imagery is created by projecting a series of 2-D bitmaps ('image slices') onto a diffuse screen that rotates at 600 rpm. Persistence of vision fuses the slices into a volume-filling 3-D image. A modified three-panel Texas Instruments projector provides slices at approximately 4 kHz, resulting in 8-color 3-D imagery comprised of roughly 200 radially-disposed slices which are updated at 20 Hz. Each slice has a resolution of 768 by 768 pixels, subtending 10 inches. An unusual off-axis projection scheme incorporating tilted rotating optics is used to maintain good focus across the projection screen. The display electronics includes a custom rasterization architecture which converts the user's 3- D geometry data into image slices, as well as 6 Gbits of DDR SDRAM graphics memory.

  16. Myocardial kinematics based on tagged MRI from volumetric NURBS models

    Science.gov (United States)

    Tustison, Nicholas J.; Amini, Amir A.

    2004-04-01

    We present current research in which left ventricular deformation is estimated from tagged cardiac magnetic resonance imaging using volumetric deformable models constructed from nonuniform rational B-splines (NURBS). From a set of short and long axis images at end-diastole, the initial NURBS model is constructed by fitting two surfaces with the same parameterization to the set of epicardial and endocardial contours from which a volumetric model is created. Using normal displacements of the three sets of orthogonal tag planes as well as displacements of both tag line and contour/tag line intersection points, one can solve for the optimal homogeneous coordinates, in a least squares sense, of the control points of the NURBS model at a later time point using quadratic programming. After fitting to all time points of data, lofting the NURBS model at each time point creates a comprehensive 4-D NURBS model. From this model, we can extract 3-D myocardial displacement fields and corresponding strain maps, which are local measures of non-rigid deformation.

  17. Volumetric breast density affects performance of digital screening mammography.

    Science.gov (United States)

    Wanders, Johanna O P; Holland, Katharina; Veldhuis, Wouter B; Mann, Ritse M; Pijnappel, Ruud M; Peeters, Petra H M; van Gils, Carla H; Karssemeijer, Nico

    2017-02-01

    To determine to what extent automatically measured volumetric mammographic density influences screening performance when using digital mammography (DM). We collected a consecutive series of 111,898 DM examinations (2003-2011) from one screening unit of the Dutch biennial screening program (age 50-75 years). Volumetric mammographic density was automatically assessed using Volpara. We determined screening performance measures for four density categories comparable to the American College of Radiology (ACR) breast density categories. Of all the examinations, 21.6% were categorized as density category 1 ('almost entirely fatty') and 41.5, 28.9, and 8.0% as category 2-4 ('extremely dense'), respectively. We identified 667 screen-detected and 234 interval cancers. Interval cancer rates were 0.7, 1.9, 2.9, and 4.4‰ and false positive rates were 11.2, 15.1, 18.2, and 23.8‰ for categories 1-4, respectively (both p-trend density categories: 85.7, 77.6, 69.5, and 61.0% for categories 1-4, respectively (p-trend density, automatically measured on digital mammograms, impacts screening performance measures along the same patterns as established with ACR breast density categories. Since measuring breast density fully automatically has much higher reproducibility than visual assessment, this automatic method could help with implementing density-based supplemental screening.

  18. Volumetric properties of human islet amyloid polypeptide in liquid water.

    Science.gov (United States)

    Brovchenko, I; Andrews, M N; Oleinikova, A

    2010-04-28

    The volumetric properties of human islet amyloid polypeptide (hIAPP) in water were studied in a wide temperature range by computer simulations. The intrinsic density rho(p) and the intrinsic thermal expansion coefficient alpha(p) of hIAPP were evaluated by taking into account the difference between the volumetric properties of hydration and bulk water. The density of hydration water rho(h) was found to decrease almost linearly with temperature upon heating and its thermal expansion coefficient was found to be notably higher than that of bulk water. The peptide surface exposed to water is more hydrophobic and its rho(h) is smaller in conformation with a larger number of intrapeptide hydrogen bonds. The two hIAPP peptides studied (with and without disulfide bridge) show negative alpha(p), which is close to zero at 250 K and decreases to approximately -1.5 x 10(-3) K(-1) upon heating to 450 K. The analysis of various structural properties of peptides shows a correlation between the intrinsic peptide volumes and the number of intrapeptide hydrogen bonds. The obtained negative values of alpha(p) can be attributed to the shrinkage of the inner voids of the peptides upon heating.

  19. Volumetric verification of multiaxis machine tool using laser tracker.

    Science.gov (United States)

    Aguado, Sergio; Samper, David; Santolaria, Jorge; Aguilar, Juan José

    2014-01-01

    This paper aims to present a method of volumetric verification in machine tools with linear and rotary axes using a laser tracker. Beyond a method for a particular machine, it presents a methodology that can be used in any machine type. Along this paper, the schema and kinematic model of a machine with three axes of movement, two linear and one rotational axes, including the measurement system and the nominal rotation matrix of the rotational axis are presented. Using this, the machine tool volumetric error is obtained and nonlinear optimization techniques are employed to improve the accuracy of the machine tool. The verification provides a mathematical, not physical, compensation, in less time than other methods of verification by means of the indirect measurement of geometric errors of the machine from the linear and rotary axes. This paper presents an extensive study about the appropriateness and drawbacks of the regression function employed depending on the types of movement of the axes of any machine. In the same way, strengths and weaknesses of measurement methods and optimization techniques depending on the space available to place the measurement system are presented. These studies provide the most appropriate strategies to verify each machine tool taking into consideration its configuration and its available work space.

  20. The Volumetric Rate of Superluminous Supernovae at z~1

    CERN Document Server

    Prajs, S; Smith, M; Levan, A; Karpenka, N V; Edwards, T D P; Walker, C R; Wolf, W M; Balland, C; Carlberg, R; Howell, A; Lidman, C; Pain, R; Pritchet, C; Ruhlmann-Kleider, V

    2016-01-01

    We present a measurement of the volumetric rate of superluminous supernovae (SLSNe) at z~1, measured using archival data from the first four years of the Canada-France-Hawaii Telescope Supernova Legacy Survey (SNLS). We develop a method for the photometric classification of SLSNe to construct our sample. Our sample includes two previously spectroscopically-identified objects, and a further new candidate selected using our classification technique. We use the point-source recovery efficiencies from Perrett et.al. (2010) and a Monte Carlo approach to calculate the rate based on our SLSN sample. We find that the three identified SLSNe from SNLS give a rate of 91 (+76/-36) SNe/Yr/Gpc^3 at a volume-weighted redshift of z=1.13. This is equivalent to 2.2 (+1.8/-0.9) x10^-4 of the volumetric core collapse supernova rate at the same redshift. When combined with other rate measurements from the literature, we show that the rate of SLSNe increases with redshift in a manner consistent with that of the cosmic star formati...

  1. Web based hybrid volumetric visualisation of urban GIS data. Integration of 4D Temperature and Wind Fields with LoD-2 CityGML models

    Science.gov (United States)

    Congote, J.; Moreno, A.; Kabongo, L.; Pérez, J.-L.; San-José, R.; Ruiz, O.

    2012-10-01

    City models visualisation, buildings, structures and volumetric information, is an important task in Computer Graphics and Urban Planning. The different formats and data sources involved in the visualisation make the development of applications a big challenge. We present a homogeneous web visualisation framework using X3DOM and MEDX3DOM for the visualisation of these urban objects. We present an integration of different declarative data sources, enabling the utilization of advanced visualisation algorithms to render the models. It has been tested with a city model composed of buildings from the Madrid University Campus, some volumetric datasets coming from Air Quality Models and 2D layers wind datasets. Results show that the visualisation of all the urban models can be performed in real time on the Web. An HTML5 web interface is presented to the users, enabling real time modifications of visualisation parameters.

  2. A study to investigate the fluid properties of fuel-vapour/air-mixtures of an automotive fuel system during refuelling. Determination of air-content, density and dynamic viscosity of the vapour-mixture in the venting of automotive fuel tanks during refuelling; Untersuchungen zur Bestimmung der Fluideigenschaften von Kraftstoffdampf-Luft-Gemischen von Kraftfahrzeuganlagen waehrend der Betankung. Bestimmung des Luftanteils, der Dichte und der dynamischen Viskositaet des Gasgemisches in der Entlueftung eines Kraftfahrzeugtanks waehrend der Betankung

    Energy Technology Data Exchange (ETDEWEB)

    Geurtz, Heinz-Juergen [Porsche AG, Weissach (Germany)

    2011-09-15

    This study investigates the methods of calculating the fluid-dynamic properties of fuel-vapour/air-mixtures. It aims to determine models for the calculation of the dynamic viscosity and density of these fuel-vapour/air-mixtures. For this purpose, fuels were analyzed. The data received were collected in a database which was complemented with the temperature-dependent vapour-pressures and dynamic viscosity-properties. Experiments were conducted in order to determine the air-content in the vapour venting from a fuel system during refueling. Based on these data conclusions can be drawn on the composition of the liquid fuel, which allows the assessment of the fuel-vapour and its properties. The results received were subsequently used to develop parametric models for the calculation of the average molecular weight, density and dynamic viscosity of fuel-vapour/air-mixtures. (orig.)

  3. Rapid mapping of volumetric machine errors using distance measurements

    Energy Technology Data Exchange (ETDEWEB)

    Krulewich, D.A.

    1998-04-01

    This paper describes a relatively inexpensive, fast, and easy to execute approach to maping the volumetric errors of a machine tool, coordinate measuring machine, or robot. An error map is used to characterize a machine or to improve its accuracy by compensating for the systematic errors. The method consists of three steps: (1) models the relationship between volumetric error and the current state of the machine, (2) acquiring error data based on distance measurements throughout the work volume; and (3)fitting the error model using the nonlinear equation for the distance. The error model is formulated from the kinematic relationship among the six degrees of freedom of error an each moving axis. Expressing each parametric error as function of position each is combined to predict the error between the functional point and workpiece, also as a function of position. A series of distances between several fixed base locations and various functional points in the work volume is measured using a Laser Ball Bar (LBB). Each measured distance is a non-linear function dependent on the commanded location of the machine, the machine error, and the location of the base locations. Using the error model, the non-linear equation is solved producing a fit for the error model Also note that, given approximate distances between each pair of base locations, the exact base locations in the machine coordinate system determined during the non-linear filling procedure. Furthermore, with the use of 2048 more than three base locations, bias error in the measuring instrument can be removed The volumetric errors of three-axis commercial machining center have been mapped using this procedure. In this study, only errors associated with the nominal position of the machine were considered Other errors such as thermally induced and load induced errors were not considered although the mathematical model has the ability to account for these errors. Due to the proprietary nature of the projects we are

  4. Quantitative volumetric Raman imaging of three dimensional cell cultures

    Science.gov (United States)

    Kallepitis, Charalambos; Bergholt, Mads S.; Mazo, Manuel M.; Leonardo, Vincent; Skaalure, Stacey C.; Maynard, Stephanie A.; Stevens, Molly M.

    2017-03-01

    The ability to simultaneously image multiple biomolecules in biologically relevant three-dimensional (3D) cell culture environments would contribute greatly to the understanding of complex cellular mechanisms and cell-material interactions. Here, we present a computational framework for label-free quantitative volumetric Raman imaging (qVRI). We apply qVRI to a selection of biological systems: human pluripotent stem cells with their cardiac derivatives, monocytes and monocyte-derived macrophages in conventional cell culture systems and mesenchymal stem cells inside biomimetic hydrogels that supplied a 3D cell culture environment. We demonstrate visualization and quantification of fine details in cell shape, cytoplasm, nucleus, lipid bodies and cytoskeletal structures in 3D with unprecedented biomolecular specificity for vibrational microspectroscopy.

  5. Optimization approaches to volumetric modulated arc therapy planning

    Energy Technology Data Exchange (ETDEWEB)

    Unkelbach, Jan, E-mail: junkelbach@mgh.harvard.edu; Bortfeld, Thomas; Craft, David [Department of Radiation Oncology, Massachusetts General Hospital and Harvard Medical School, Boston, Massachusetts 02114 (United States); Alber, Markus [Department of Medical Physics and Department of Radiation Oncology, Aarhus University Hospital, Aarhus C DK-8000 (Denmark); Bangert, Mark [Department of Medical Physics in Radiation Oncology, German Cancer Research Center, Heidelberg D-69120 (Germany); Bokrantz, Rasmus [RaySearch Laboratories, Stockholm SE-111 34 (Sweden); Chen, Danny [Department of Computer Science and Engineering, University of Notre Dame, Notre Dame, Indiana 46556 (United States); Li, Ruijiang; Xing, Lei [Department of Radiation Oncology, Stanford University, Stanford, California 94305 (United States); Men, Chunhua [Department of Research, Elekta, Maryland Heights, Missouri 63043 (United States); Nill, Simeon [Joint Department of Physics at The Institute of Cancer Research and The Royal Marsden NHS Foundation Trust, London SM2 5NG (United Kingdom); Papp, Dávid [Department of Mathematics, North Carolina State University, Raleigh, North Carolina 27695 (United States); Romeijn, Edwin [H. Milton Stewart School of Industrial and Systems Engineering, Georgia Institute of Technology, Atlanta, Georgia 30332 (United States); Salari, Ehsan [Department of Industrial and Manufacturing Engineering, Wichita State University, Wichita, Kansas 67260 (United States)

    2015-03-15

    Volumetric modulated arc therapy (VMAT) has found widespread clinical application in recent years. A large number of treatment planning studies have evaluated the potential for VMAT for different disease sites based on the currently available commercial implementations of VMAT planning. In contrast, literature on the underlying mathematical optimization methods used in treatment planning is scarce. VMAT planning represents a challenging large scale optimization problem. In contrast to fluence map optimization in intensity-modulated radiotherapy planning for static beams, VMAT planning represents a nonconvex optimization problem. In this paper, the authors review the state-of-the-art in VMAT planning from an algorithmic perspective. Different approaches to VMAT optimization, including arc sequencing methods, extensions of direct aperture optimization, and direct optimization of leaf trajectories are reviewed. Their advantages and limitations are outlined and recommendations for improvements are discussed.

  6. Volumetric properties of water/AOT/isooctane microemulsions.

    Science.gov (United States)

    Du, Changfei; He, Wei; Yin, Tianxiang; Shen, Weiguo

    2014-12-23

    The densities of AOT/isooctane micelles and water/AOT/isooctane microemulsions with the molar ratios R of water to AOT being 2, 8, 10, 12, 16, 18, 20, 25, 30, and 40 were measured at 303.15 K. The apparent specific volumes of AOT and the quasi-component water/AOT at various concentrations were calculated and used to estimate the volumetric properties of AOT and water in the droplets and in the continuous oil phase, to discuss the interaction between the droplets, and to determine the critical micelle concentration and the critical microemulsion concentrations. A thermodynamic model was proposed to analysis the stability boundary of the microemulsion droplets, which confirms the maximum value of R being about 65 for the stable AOT/water/isooctane microemulsion droplets.

  7. Quantitative volumetric Raman imaging of three dimensional cell cultures

    KAUST Repository

    Kallepitis, Charalambos

    2017-03-22

    The ability to simultaneously image multiple biomolecules in biologically relevant three-dimensional (3D) cell culture environments would contribute greatly to the understanding of complex cellular mechanisms and cell–material interactions. Here, we present a computational framework for label-free quantitative volumetric Raman imaging (qVRI). We apply qVRI to a selection of biological systems: human pluripotent stem cells with their cardiac derivatives, monocytes and monocyte-derived macrophages in conventional cell culture systems and mesenchymal stem cells inside biomimetic hydrogels that supplied a 3D cell culture environment. We demonstrate visualization and quantification of fine details in cell shape, cytoplasm, nucleus, lipid bodies and cytoskeletal structures in 3D with unprecedented biomolecular specificity for vibrational microspectroscopy.

  8. In-line hologram segmentation for volumetric samples.

    Science.gov (United States)

    Orzó, László; Göröcs, Zoltán; Fehér, András; Tőkés, Szabolcs

    2013-01-01

    We propose a fast, noniterative method to segment an in-line hologram of a volumetric sample into in-line subholograms according to its constituent objects. In contrast to the phase retrieval or twin image elimination algorithms, we do not aim or require to reconstruct the complex wave field of all the objects, which would be a more complex task, but only provide a good estimate about the contribution of the particular objects to the original hologram quickly. The introduced hologram segmentation algorithm exploits the special inner structure of the in-line holograms and applies only the estimated supports and reconstruction distances of the corresponding objects as parameters. The performance of the proposed method is demonstrated and analyzed experimentally both on synthetic and measured holograms. We discussed how the proposed algorithm can be efficiently applied for object reconstruction and phase retrieval tasks.

  9. Three-Dimensional Volumetric Restoration by Structural Fat Grafting

    Science.gov (United States)

    Clauser, Luigi C.; Consorti, Giuseppe; Elia, Giovanni; Galié, Manlio; Tieghi, Riccardo

    2013-01-01

    The use of adipose tissue transfer for correction of maxillofacial defects was reported for the first time at the end of the 19th century. Structural fat grafting (SFG) was introduced as a way to improve facial esthetics and in recent years has evolved into applications in craniomaxillofacial reconstructive surgery. Several techniques have been proposed for harvesting and grafting the fat. However, owing to the damage of many adipocytes during these maneuvers, the results have not been satisfactory and have required several fat injection procedures for small corrections. The author's (L.C.) overview the application of SFG in the management of volumetric deficit in the craniomaxillofacial in patients treated with a long-term follow-up. PMID:24624259

  10. Semi-automatic volumetrics system to parcellate ROI on neocortex

    Science.gov (United States)

    Tan, Ou; Ichimiya, Tetsuya; Yasuno, Fumihiko; Suhara, Tetsuya

    2002-05-01

    A template-based and semi-automatic volumetrics system--BrainVol is build to divide the any given patient brain to neo-cortical and sub-cortical regions. The standard region is given as standard ROI drawn on a standard brain volume. After normalization between the standard MR image and the patient MR image, the sub-cortical ROIs' boundary are refined based on gray matter. The neo-cortical ROIs are refined by sulcus information that is semi-automatically marked on the patient brain. Then the segmentation is applied to 4D PET image of same patient for calculation of TAC (Time Activity Curve) by co-registration between MR and PET.

  11. Out-of-core clustering of volumetric datasets

    Institute of Scientific and Technical Information of China (English)

    GRANBERG Carl J.; LI Ling

    2006-01-01

    In this paper we present a novel method for dividing and clustering large volumetric scalar out-of-core datasets. This work is based on the Ordered Cluster Binary Tree (OCBT) structure created using a top-down or divisive clustering method. The OCBT structure allows fast and efficient sub volume queries to be made in combination with level of detail (LOD) queries of the tree. The initial partitioning of the large out-of-core dataset is done by using non-axis aligned planes calculated using Principal Component Analysis (PCA). A hybrid OCBT structure is also proposed where an in-core cluster binary tree is combined with a large out-of-core file.

  12. Volumetric Survey Speed: A Figure of Merit for Transient Surveys

    CERN Document Server

    Bellm, Eric C

    2016-01-01

    Time-domain surveys can exchange sky coverage for revisit frequency, complicating the comparison of their relative capabilities. By using different revisit intervals, a specific camera may execute surveys optimized for discovery of different classes of transient objects. We propose a new figure of merit, the instantaneous volumetric survey speed, for evaluating transient surveys. This metric defines the trade between cadence interval and snapshot survey volume and so provides a natural means of comparing survey capability. The related metric of areal survey speed imposes a constraint on the range of possible revisit times: we show that many modern time-domain surveys are limited by the amount of fresh sky available each night. We introduce the concept of "spectroscopic accessibility" and discuss its importance for transient science goals requiring followup observing. We present an extension of the control time algorithm for cases where multiple consecutive detections are required. Finally, we explore how surv...

  13. Large-scale volumetric pressure from tomographic PTV with HFSB tracers

    Science.gov (United States)

    Schneiders, Jan F. G.; Caridi, Giuseppe C. A.; Sciacchitano, Andrea; Scarano, Fulvio

    2016-11-01

    The instantaneous volumetric pressure in the near-wake of a truncated cylinder is measured by use of tomographic particle tracking velocimetry (PTV) using helium-filled soap bubbles (HFSB) as tracers. The measurement volume is several orders of magnitude larger than that reported in tomographic experiments dealing with pressure from particle image velocimetry (PIV). The near-wake of a truncated cylinder installed on a flat plate ( Re D = 3.5 × 104) features both wall-bounded turbulence and large-scale unsteady flow separation. The instantaneous pressure is calculated from the time-resolved 3D velocity distribution by invoking the momentum equation. The experiments are conducted simultaneously with surface pressure measurements intended for validation of the technique. The study shows that time-averaged pressure and root-mean-squared pressure fluctuations can be accurately measured both in the fluid domain and at the solid surface by large-scale tomographic PTV with HFSB as tracers, with significant reduction in manufacturing complexity for the wind-tunnel model and circumventing the need to install pressure taps or transducers. The measurement over a large volume eases the extension toward the free-stream regime, providing a reliable boundary condition for the solution of the Poisson equation for pressure. The work demonstrates, in the case of the flow past a truncated cylinder, the use of HFSB tracer particles for pressure measurement in air flows in a measurement volume that is two orders of magnitude larger than that of conventional tomographic PIV.

  14. Simulations of the Richtmyer-Meshkov Instability with experimentally measured volumetric initial conditions

    Science.gov (United States)

    Ferguson, Kevin; Sewell, Everest; Krivets, Vitaliy; Greenough, Jeffrey; Jacobs, Jeffrey

    2016-11-01

    Initial conditions for the Richtmyer-Meshkov instability (RMI) are measured in three dimensions in the University of Arizona Vertical Shock Tube using a moving magnet galvanometer system. The resulting volumetric data is used as initial conditions for the simulation of the RMI using ARES at Lawrence-Livermore National Laboratory (LLNL). The heavy gas is sulfur hexafluoride (SF6), and the light gas is air. The perturbations are generated by harmonically oscillating the gasses vertically using two loudspeakers mounted to the shock tube which cause Faraday resonance, producing a random short wavelength perturbation on the interface. Planar Mie scattering is used to illuminate the flow field through the addition of propylene glycol particles seeded in the heavy gas. An M=1.2 shock impulsively accelerates the interface, initiating instability growth. Images of the initial condition and instability growth are captured at a rate of 6 kHz using high speed cameras. Comparisons between experimental and simulation results, mixing diagnostics, and mixing zone growth are presented.

  15. Volumetric optical coherence microscopy enabled by aberrated optics (Conference Presentation)

    Science.gov (United States)

    Mulligan, Jeffrey A.; Liu, Siyang; Adie, Steven G.

    2017-02-01

    Optical coherence microscopy (OCM) is an interferometric imaging technique that enables high resolution, non-invasive imaging of 3D cell cultures and biological tissues. Volumetric imaging with OCM suffers a trade-off between high transverse resolution and poor depth-of-field resulting from defocus, optical aberrations, and reduced signal collection away from the focal plane. While defocus and aberrations can be compensated with computational methods such as interferometric synthetic aperture microscopy (ISAM) or computational adaptive optics (CAO), reduced signal collection must be physically addressed through optical hardware. Axial scanning of the focus is one approach, but comes at the cost of longer acquisition times, larger datasets, and greater image reconstruction times. Given the capabilities of CAO to compensate for general phase aberrations, we present an alternative method to address the signal collection problem without axial scanning by using intentionally aberrated optical hardware. We demonstrate the use of an astigmatic spectral domain (SD-)OCM imaging system to enable single-acquisition volumetric OCM in 3D cell culture over an extended depth range, compared to a non-aberrated SD-OCM system. The transverse resolution of the non-aberrated and astigmatic imaging systems after application of CAO were 2 um and 2.2 um, respectively. The depth-range of effective signal collection about the nominal focal plane was increased from 100 um in the non-aberrated system to over 300 um in the astigmatic system, extending the range over which useful data may be acquired in a single OCM dataset. We anticipate that this method will enable high-throughput cellular-resolution imaging of dynamic biological systems over extended volumes.

  16. Marginal Space Deep Learning: Efficient Architecture for Volumetric Image Parsing.

    Science.gov (United States)

    Ghesu, Florin C; Krubasik, Edward; Georgescu, Bogdan; Singh, Vivek; Yefeng Zheng; Hornegger, Joachim; Comaniciu, Dorin

    2016-05-01

    Robust and fast solutions for anatomical object detection and segmentation support the entire clinical workflow from diagnosis, patient stratification, therapy planning, intervention and follow-up. Current state-of-the-art techniques for parsing volumetric medical image data are typically based on machine learning methods that exploit large annotated image databases. Two main challenges need to be addressed, these are the efficiency in scanning high-dimensional parametric spaces and the need for representative image features which require significant efforts of manual engineering. We propose a pipeline for object detection and segmentation in the context of volumetric image parsing, solving a two-step learning problem: anatomical pose estimation and boundary delineation. For this task we introduce Marginal Space Deep Learning (MSDL), a novel framework exploiting both the strengths of efficient object parametrization in hierarchical marginal spaces and the automated feature design of Deep Learning (DL) network architectures. In the 3D context, the application of deep learning systems is limited by the very high complexity of the parametrization. More specifically 9 parameters are necessary to describe a restricted affine transformation in 3D, resulting in a prohibitive amount of billions of scanning hypotheses. The mechanism of marginal space learning provides excellent run-time performance by learning classifiers in clustered, high-probability regions in spaces of gradually increasing dimensionality. To further increase computational efficiency and robustness, in our system we learn sparse adaptive data sampling patterns that automatically capture the structure of the input. Given the object localization, we propose a DL-based active shape model to estimate the non-rigid object boundary. Experimental results are presented on the aortic valve in ultrasound using an extensive dataset of 2891 volumes from 869 patients, showing significant improvements of up to 45

  17. The volumetric rate of superluminous supernovae at z ˜ 1

    Science.gov (United States)

    Prajs, S.; Sullivan, M.; Smith, M.; Levan, A.; Karpenka, N. V.; Edwards, T. D. P.; Walker, C. R.; Wolf, W. M.; Balland, C.; Carlberg, R.; Howell, D. A.; Lidman, C.; Pain, R.; Pritchet, C.; Ruhlmann-Kleider, V.

    2017-01-01

    We present a measurement of the volumetric rate of superluminous supernovae (SLSNe) at z ˜ 1.0, measured using archival data from the first four years of the Canada-France-Hawaii Telescope Supernova Legacy Survey (SNLS). We develop a method for the photometric classification of SLSNe to construct our sample. Our sample includes two previously spectroscopically identified objects, and a further new candidate selected using our classification technique. We use the point-source recovery efficiencies from Perrett et al. and a Monte Carlo approach to calculate the rate based on our SLSN sample. We find that the three identified SLSNe from SNLS give a rate of 91^{+76}_{-36} SNe yr-1 Gpc-3 at a volume-weighted redshift of z = 1.13. This is equivalent to 2.2^{+1.8}_{-0.9}× 10^{-4} of the volumetric core-collapse supernova rate at the same redshift. When combined with other rate measurements from the literature, we show that the rate of SLSNe increases with redshift in a manner consistent with that of the cosmic star formation history. We also estimate the rate of ultra-long gamma-ray bursts based on the events discovered by the Swift satellite, and show that it is comparable to the rate of SLSNe, providing further evidence of a possible connection between these two classes of events. We also examine the host galaxies of the SLSNe discovered in SNLS, and find them to be consistent with the stellar-mass distribution of other published samples of SLSNe.

  18. Volumetric analysis of corticocancellous bones using CT data

    Energy Technology Data Exchange (ETDEWEB)

    Krappinger, Dietmar; Linde, Astrid von; Rosenberger, Ralf; Blauth, Michael [Medical University Innsbruck, Department of Trauma Surgery and Sports Medicine, Innsbruck (Austria); Glodny, Bernhard; Niederwanger, Christian [Medical University Innsbruck, Department of Radiology I, Innsbruck (Austria)

    2012-05-15

    To present a method for an automated volumetric analysis of corticocancellous bones such as the superior pubic ramus using CT data and to assess the reliability of this method. Computed tomography scans of a consecutive series of 250 patients were analyzed. A Hounsfield unit (HU) thresholding-based reconstruction technique (''Vessel Tracking,'' GE Healthcare) was used. A contiguous space of cancellous bone with similar HU values between the starting and end points was automatically identified as the region of interest. The identification was based upon the density gradient to the adjacent cortical bone. The starting point was defined as the middle of the parasymphyseal corticocancellous transition zone on the axial slice showing the parasymphyseal superior pubic ramus in its maximum anteroposterior width. The end point was defined as the middle of the periarticular corticocancellous transition zone on the axial slice showing the quadrilateral plate as a thin cortical plate. The following parameters were automatically obtained on both sides: length of the center line, volume of the superior pubic ramus between the starting point and end point, minimum, maximum and mean diameter perpendicular to the center line, and mean cross-sectional area perpendicular to the center line. An automated analysis without manual adjustments was successful in 207 patients (82.8%). The center line showed a significantly greater length in female patients (67.6 mm vs 65.0 mm). The volume was greater in male patients (21.8 cm{sup 3} vs 19.4 cm{sup 3}). The intersite reliability was high with a mean difference between the left and right sides of between 0.1% (cross-sectional area) and 2.3% (volume). The method presented allows for an automated volumetric analysis of a corticocancellous bone using CT data. The method is intended to provide preoperative information for the use of intramedullary devices in fracture fixation and percutaneous cement augmentation techniques

  19. An Analysis Methodology for Stochastic Characteristic of Volumetric Error in Multiaxis CNC Machine Tool

    Directory of Open Access Journals (Sweden)

    Qiang Cheng

    2013-01-01

    Full Text Available Traditional approaches about error modeling and analysis of machine tool few consider the probability characteristics of the geometric error and volumetric error systematically. However, the individual geometric error measured at different points is variational and stochastic, and therefore the resultant volumetric error is aslo stochastic and uncertain. In order to address the stochastic characteristic of the volumetric error for multiaxis machine tool, a new probability analysis mathematical model of volumetric error is proposed in this paper. According to multibody system theory, a mean value analysis model for volumetric error is established with consideration of geometric errors. The probability characteristics of geometric errors are obtained by statistical analysis to the measured sample data. Based on probability statistics and stochastic process theory, the variance analysis model of volumetric error is established in matrix, which can avoid the complex mathematics operations during the direct differential. A four-axis horizontal machining center is selected as an illustration example. The analysis results can reveal the stochastic characteristic of volumetric error and are also helpful to make full use of the best workspace to reduce the random uncertainty of the volumetric error and improve the machining accuracy.

  20. Volumetric and two-dimensional image interpretation show different cognitive processes in learners

    NARCIS (Netherlands)

    van der Gijp, Anouk; Ravesloot, C.J.; van der Schaaf, Marieke F; van der Schaaf, Irene C; Huige, Josephine C B M; Vincken, Koen L; Ten Cate, Olle Th J; van Schaik, JPJ

    2015-01-01

    RATIONALE AND OBJECTIVES: In current practice, radiologists interpret digital images, including a substantial amount of volumetric images. We hypothesized that interpretation of a stack of a volumetric data set demands different skills than interpretation of two-dimensional (2D) cross-sectional imag

  1. Air Pollution

    Science.gov (United States)

    Air pollution is a mixture of solid particles and gases in the air. Car emissions, chemicals from factories, ... Ozone, a gas, is a major part of air pollution in cities. When ozone forms air pollution, it's ...

  2. High Volumetric Energy Density Hybrid Supercapacitors Based on Reduced Graphene Oxide Scrolls.

    Science.gov (United States)

    Rani, Janardhanan R; Thangavel, Ranjith; Oh, Se-I; Woo, Jeong Min; Chandra Das, Nayan; Kim, So-Yeon; Lee, Yun-Sung; Jang, Jae-Hyung

    2017-07-12

    The low volumetric energy density of reduced graphene oxide (rGO)-based electrodes limits its application in commercial electrochemical energy storage devices that require high-performance energy storage capacities in small volumes. The volumetric energy density of rGO-based electrode materials is very low due to their low packing density. A supercapacitor with enhanced packing density and high volumetric energy density is fabricated using doped rGO scrolls (GFNSs) as the electrode material. The restacking of rGO sheets is successfully controlled through synthesizing the doped scroll structures while increasing the packing density. The fabricated cell exhibits an ultrahigh volumetric energy density of 49.66 Wh/L with excellent cycling stability (>10 000 cycles). This unique design strategy for the electrode material has significant potential for the future supercapacitors with high volumetric energy densities.

  3. Global segmentation and curvature analysis of volumetric data sets using trivariate B-spline functions.

    Science.gov (United States)

    Soldea, Octavian; Elber, Gershon; Rivlin, Ehud

    2006-02-01

    This paper presents a method to globally segment volumetric images into regions that contain convex or concave (elliptic) iso-surfaces, planar or cylindrical (parabolic) iso-surfaces, and volumetric regions with saddle-like (hyperbolic) iso-surfaces, regardless of the value of the iso-surface level. The proposed scheme relies on a novel approach to globally compute, bound, and analyze the Gaussian and mean curvatures of an entire volumetric data set, using a trivariate B-spline volumetric representation. This scheme derives a new differential scalar field for a given volumetric scalar field, which could easily be adapted to other differential properties. Moreover, this scheme can set the basis for more precise and accurate segmentation of data sets targeting the identification of primitive parts. Since the proposed scheme employs piecewise continuous functions, it is precise and insensitive to aliasing.

  4. The duct selective volumetric receiver: potential for different selectivity strategies and stability issues

    Energy Technology Data Exchange (ETDEWEB)

    Garcia-Casals, X. [Universidad Pontificia Comillas-ICAI, Madrid (Spain). Dept. de Fluidos y Calor; Ajona, J.I. [Departamento de Energia Solar, Viessemann, Poligono Industrial San Marcos, Getafe (Spain)

    1999-07-01

    Recently much theoretical and experimental work has been conducted on volumetric receivers. However, not much attention has been paid to the possibilities of using different selectivity mechanisms to minimize radiation thermal losses, which are the main ones at high operating temperature. In this paper we present a duct volumetric receiver model and its results, which allow the evaluation of different selectivity strategies such as: conventional {epsilon}/{alpha}, geometry, frontal absorption and diffuse/specular reflection. We propose a new concept of selective volumetric receivers based on a solar-specular/infrared-diffuse radiative behaviour and evaluate its potential for efficiency improvement. In recent work on volumetric receivers based on simplified models, it has been concluded that the duct volumetric receiver is inherently unstable when working with high solar flux. We didn't find any unstable receiver behaviour even at very high solar fluxes, and conclude that a substantial potential for efficiency improvement exists if selectivity mechanisms are properly combined. (author)

  5. Enhanced volumetric visualization for real time 4D intraoperative ophthalmic swept-source OCT.

    Science.gov (United States)

    Viehland, Christian; Keller, Brenton; Carrasco-Zevallos, Oscar M; Nankivil, Derek; Shen, Liangbo; Mangalesh, Shwetha; Viet, Du Tran; Kuo, Anthony N; Toth, Cynthia A; Izatt, Joseph A

    2016-05-01

    Current-generation software for rendering volumetric OCT data sets based on ray casting results in volume visualizations with indistinct tissue features and sub-optimal depth perception. Recent developments in hand-held and microscope-integrated intrasurgical OCT designed for real-time volumetric imaging motivate development of rendering algorithms which are both visually appealing and fast enough to support real time rendering, potentially from multiple viewpoints for stereoscopic visualization. We report on an enhanced, real time, integrated volumetric rendering pipeline which incorporates high performance volumetric median and Gaussian filtering, boundary and feature enhancement, depth encoding, and lighting into a ray casting volume rendering model. We demonstrate this improved model implemented on graphics processing unit (GPU) hardware for real-time volumetric rendering of OCT data during tissue phantom and live human surgical imaging. We show that this rendering produces enhanced 3D visualizations of pathology and intraoperative maneuvers compared to standard ray casting.

  6. 19 CFR 122.114 - Contents.

    Science.gov (United States)

    2012-04-01

    ... 19 Customs Duties 1 2012-04-01 2012-04-01 false Contents. 122.114 Section 122.114 Customs Duties U.S. CUSTOMS AND BORDER PROTECTION, DEPARTMENT OF HOMELAND SECURITY; DEPARTMENT OF THE TREASURY AIR COMMERCE REGULATIONS Transit Air Cargo Manifest (TACM) Procedures § 122.114 Contents. (a) Form duplicates...

  7. 19 CFR § 122.114 - Contents.

    Science.gov (United States)

    2015-04-01

    ... 19 Customs Duties 1 2015-04-01 2015-04-01 false Contents. § 122.114 Section § 122.114 Customs Duties U.S. CUSTOMS AND BORDER PROTECTION, DEPARTMENT OF HOMELAND SECURITY; DEPARTMENT OF THE TREASURY AIR COMMERCE REGULATIONS Transit Air Cargo Manifest (TACM) Procedures § 122.114 Contents. (a) Form...

  8. A new method using evaporation for high-resolution measurements of soil thermal conductivity at changing water contents

    Science.gov (United States)

    Markert, A.; Trinks, S.; Facklam, M.; Wessolek, G.

    2012-04-01

    The thermal conductivity of soils is a key parameter to know if their use as heat source or sink is planned. It is required to calculate the efficiency of ground-source heat pump systems in combination with soil heat exchangers. Apart from geothermal energy, soil thermal conductivity is essential to estimate the ampacity for buried power cables. The effective thermal conductivity of saturated and unsaturated soils, as a function of water transport, water vapour transport and heat conduction, mainly depends on the soil water content, its bulk density and texture. The major objectives of this study are (i) to describe the thermal conductivity of soil samples with a non-steady state measurement at changing water contents and for different bulk densities. Based on that it is (ii) tested if available soil thermal conductivity models are able to describe the measured data for the whole range of water contents. The new method allows a continuous measurement of thermal conductivity for soil from full water saturation to air-dryness. Thermal conductivity is measured with a thermal needle probe in predefined time intervals while the change of water content is controlled by evaporation. To relate the measured thermal conductivity to the current volumetric water content, the decrease in weight of the sample, due to evaporation, is logged with a lab scale. Soil texture of the 11 soil substrates tested in this study range between coarse sand and silty clay. To evaluate the impact of the bulk density on heat transport processes, thermal conductivity at 20°C was measured at 1.5g/cm3; 1.7g/cm3 and 1.9g/cm3 for each soil substrate. The results correspond well to literature values used to describe heat transport in soils. Due to the high-resolution and non-destructive measurements, the specific effects of the soil texture and bulk density on thermal conductivity could be proved. Decreasing water contents resulted in a non-linear decline of the thermal conductivity for all samples

  9. Volumetric and two-dimensional image interpretation show different cognitive processes in learners.

    Science.gov (United States)

    van der Gijp, Anouk; Ravesloot, Cécile J; van der Schaaf, Marieke F; van der Schaaf, Irene C; Huige, Josephine C B M; Vincken, Koen L; Ten Cate, Olle Th J; van Schaik, Jan P J

    2015-05-01

    In current practice, radiologists interpret digital images, including a substantial amount of volumetric images. We hypothesized that interpretation of a stack of a volumetric data set demands different skills than interpretation of two-dimensional (2D) cross-sectional images. This study aimed to investigate and compare knowledge and skills used for interpretation of volumetric versus 2D images. Twenty radiology clerks were asked to think out loud while reading four or five volumetric computed tomography (CT) images in stack mode and four or five 2D CT images. Cases were presented in a digital testing program allowing stack viewing of volumetric data sets and changing views and window settings. Thoughts verbalized by the participants were registered and coded by a framework of knowledge and skills concerning three components: perception, analysis, and synthesis. The components were subdivided into 16 discrete knowledge and skill elements. A within-subject analysis was performed to compare cognitive processes during volumetric image readings versus 2D cross-sectional image readings. Most utterances contained knowledge and skills concerning perception (46%). A smaller part involved synthesis (31%) and analysis (23%). More utterances regarded perception in volumetric image interpretation than in 2D image interpretation (Median 48% vs 35%; z = -3.9; P Cognitive processes in volumetric and 2D cross-sectional image interpretation differ substantially. Volumetric image interpretation draws predominantly on perceptual processes, whereas 2D image interpretation is mainly characterized by synthesis. The results encourage the use of volumetric images for teaching and testing perceptual skills. Copyright © 2015 AUR. Published by Elsevier Inc. All rights reserved.

  10. Effect of rhythmic gymnastics on volumetric bone mineral density and bone geometry in premenarcheal female athletes and controls.

    Science.gov (United States)

    Tournis, S; Michopoulou, E; Fatouros, I G; Paspati, I; Michalopoulou, M; Raptou, P; Leontsini, D; Avloniti, A; Krekoukia, M; Zouvelou, V; Galanos, A; Aggelousis, N; Kambas, A; Douroudos, I; Lyritis, G P; Taxildaris, K; Pappaioannou, N

    2010-06-01

    Weight-bearing exercise during growth exerts positive effects on the skeleton. Our objective was to test the hypothesis that long-term elite rhythmic gymnastics exerts positive effects on volumetric bone mineral density and geometry and to determine whether exercise-induced bone adaptation is associated with increased periosteal bone formation or medullary contraction using tibial peripheral quantitative computed tomography and bone turnover markers. We conducted a cross-sectional study at a tertiary center. We studied 26 elite premenarcheal female rhythmic gymnasts (RG) and 23 female controls, aged 9-13 yr. We measured bone age, volumetric bone mineral density, bone mineral content (BMC), cortical thickness, cortical and trabecular area, and polar stress strength index (SSIp) by peripheral quantitative computed tomography of the left tibia proximal to the distal metaphysis (trabecular) at 14, 38 (cortical), and 66% (muscle mass) from the distal end and bone turnover markers. The two groups were comparable according to height and chronological and bone age. After weight adjustment, cortical BMC, area, and thickness at 38% were significantly higher in RG (P < 0.005-0.001). Periosteal circumference, SSIp, and muscle area were higher in RG (P < 0.01-0.001). Muscle area was significantly associated with cortical BMC, area, and SSIp, whereas years of training showed positive association with cortical BMC, area, and thickness independent of chronological age. RG in premenarcheal girls may induce positive adaptations on the skeleton, especially in cortical bone. Increased duration of exercise is associated with a positive response of bone geometry.

  11. Oxygen and nitrogen co-doped porous carbon nanosheets derived from Perilla frutescens for high volumetric performance supercapacitors

    Science.gov (United States)

    Liu, Bei; Liu, Yijiang; Chen, Hongbiao; Yang, Mei; Li, Huaming

    2017-02-01

    Biomass-derived O/N-co-doped porous carbons have become the most competitive electrode materials for supercapacitors because of their renewability and sustainability. We herein present a simple approach to fabricate O/N-co-doped porous carbon nanosheets by the direct pyrolysis of Perilla frutescens (PF) leaves. Under optimum pyrolysis temperature (700 °C), the PF leaf-derived carbon nanosheets (PFC-700) having O, N contents of 18.76 at.% and 1.70 at.%, respectively, exhibit a hierarchical pore structure with a moderate BET surface area (655 m2 g-1) and a relatively low pore volume (0.44 cm3 g-1). Such O/N-co-doped porous carbon nanosheets display both high gravimetric capacitance (270 F g-1 at 0.5 A g-1) and high volumetric capacitance (287 F cm-3 at 0.5 A g-1). In addition, the PFC-700-based symmetric supercapacitor offers a high volumetric energy density (14.8 Wh L-1 at 490 W L-1) as well as a high stability (about 96.1% of capacitance retention after 10000 cycles at 2 A g-1).

  12. Volumetric Spectroscopic Imaging of Glioblastoma Multiforme Radiation Treatment Volumes

    Energy Technology Data Exchange (ETDEWEB)

    Parra, N. Andres [Department of Radiation Oncology, University of Miami Miller School of Medicine, Miami, Florida (United States); Maudsley, Andrew A. [Department of Radiology, University of Miami Miller School of Medicine, Miami, Florida (United States); Gupta, Rakesh K. [Department of Radiology and Imaging, Fortis Memorial Research Institute, Gurgaon, Haryana (India); Ishkanian, Fazilat; Huang, Kris [Department of Radiation Oncology, University of Miami Miller School of Medicine, Miami, Florida (United States); Walker, Gail R. [Biostatistics and Bioinformatics Core Resource, Sylvester Cancer Center, University of Miami Miller School of Medicine, Miami, Florida (United States); Padgett, Kyle [Department of Radiation Oncology, University of Miami Miller School of Medicine, Miami, Florida (United States); Department of Radiology, University of Miami Miller School of Medicine, Miami, Florida (United States); Roy, Bhaswati [Department of Radiology and Imaging, Fortis Memorial Research Institute, Gurgaon, Haryana (India); Panoff, Joseph; Markoe, Arnold [Department of Radiation Oncology, University of Miami Miller School of Medicine, Miami, Florida (United States); Stoyanova, Radka, E-mail: RStoyanova@med.miami.edu [Department of Radiation Oncology, University of Miami Miller School of Medicine, Miami, Florida (United States)

    2014-10-01

    Purpose: Magnetic resonance (MR) imaging and computed tomography (CT) are used almost exclusively in radiation therapy planning of glioblastoma multiforme (GBM), despite their well-recognized limitations. MR spectroscopic imaging (MRSI) can identify biochemical patterns associated with normal brain and tumor, predominantly by observation of choline (Cho) and N-acetylaspartate (NAA) distributions. In this study, volumetric 3-dimensional MRSI was used to map these compounds over a wide region of the brain and to evaluate metabolite-defined treatment targets (metabolic tumor volumes [MTV]). Methods and Materials: Volumetric MRSI with effective voxel size of ∼1.0 mL and standard clinical MR images were obtained from 19 GBM patients. Gross tumor volumes and edema were manually outlined, and clinical target volumes (CTVs) receiving 46 and 60 Gy were defined (CTV{sub 46} and CTV{sub 60}, respectively). MTV{sub Cho} and MTV{sub NAA} were constructed based on volumes with high Cho and low NAA relative to values estimated from normal-appearing tissue. Results: The MRSI coverage of the brain was between 70% and 76%. The MTV{sub NAA} were almost entirely contained within the edema, and the correlation between the 2 volumes was significant (r=0.68, P=.001). In contrast, a considerable fraction of MTV{sub Cho} was outside of the edema (median, 33%) and for some patients it was also outside of the CTV{sub 46} and CTV{sub 60}. These untreated volumes were greater than 10% for 7 patients (37%) in the study, and on average more than one-third (34.3%) of the MTV{sub Cho} for these patients were outside of CTV{sub 60}. Conclusions: This study demonstrates the potential usefulness of whole-brain MRSI for radiation therapy planning of GBM and revealed that areas of metabolically active tumor are not covered by standard RT volumes. The described integration of MTV into the RT system will pave the way to future clinical trials investigating outcomes in patients treated based on

  13. Volumetric capnography for the evaluation of chronic airways diseases

    Directory of Open Access Journals (Sweden)

    Veronez L

    2014-09-01

    Full Text Available Liliani de Fátima Veronez,1 Monica Corso Pereira,2 Silvia Maria Doria da Silva,2 Luisa Affi Barcaui,2 Eduardo Mello De Capitani,2 Marcos Mello Moreira,2 Ilma Aparecida Paschoalz2 1Department of Physical Therapy, University of Votuporanga (Educational Foundation of Votuporanga, Votuporanga, 2Department of Internal Medicine, School of Medical Sciences, State University of Campinas (UNICAMP, Campinas, Sao Paulo, BrazilBackground: Obstructive lung diseases of different etiologies present with progressive peripheral airway involvement. The peripheral airways, known as the silent lung zone, are not adequately evaluated with conventional function tests. The principle of gas washout has been used to detect pulmonary ventilation inhomogeneity and to estimate the location of the underlying disease process. Volumetric capnography (VC analyzes the pattern of CO2 elimination as a function of expired volume.Objective: To measure normalized phase 3 slopes with VC in patients with non-cystic fibrosis bronchiectasis (NCB and in bronchitic patients with chronic obstructive pulmonary disease (COPD in order to compare the slopes obtained for the groups.Methods: NCB and severe COPD were enrolled sequentially from an outpatient clinic (Hospital of the State University of Campinas. A control group was established for the NCB group, paired by sex and age. All subjects performed spirometry, VC, and the 6-Minute Walk Test (6MWT. Two comparisons were made: NCB group versus its control group, and NCB group versus COPD group. The project was approved by the ethical committee of the institution. Statistical tests used were Wilcoxon or Student’s t-test; P<0.05 was considered to be a statistically significant difference.Results: Concerning the NCB group (N=20 versus the control group (N=20, significant differences were found in body mass index and in several functional variables (spirometric, VC, 6MWT with worse results observed in the NCB group. In the comparison between

  14. Widespread Volumetric Brain Changes following Tooth Loss in Female Mice

    Science.gov (United States)

    Avivi-Arber, Limor; Seltzer, Ze'ev; Friedel, Miriam; Lerch, Jason P.; Moayedi, Massieh; Davis, Karen D.; Sessle, Barry J.

    2017-01-01

    Tooth loss is associated with altered sensory, motor, cognitive and emotional functions. These changes vary highly in the population and are accompanied by structural and functional changes in brain regions mediating these functions. It is unclear to what extent this variability in behavior and function is caused by genetic and/or environmental determinants and which brain regions undergo structural plasticity that mediates these changes. Thus, the overall goal of our research program is to identify genetic variants that control structural and functional plasticity following tooth loss. As a step toward this goal, here our aim was to determine whether structural magnetic resonance imaging (sMRI) is sensitive to detect quantifiable volumetric differences in the brains of mice of different genetic background receiving tooth extraction or sham operation. We used 67 adult female mice of 7 strains, comprising the A/J (A) and C57BL/6J (B) strains and a randomly selected sample of 5 of the 23 AXB-BXA strains (AXB1, AXB4, AXB24, BXA14, BXA24) that were produced from the A and B parental mice by recombinations and inbreeding. This panel of 25 inbred strains of genetically diverse inbred strains of mice is used for mapping chromosomal intervals throughout the genome that harbor candidate genes controlling the phenotypic variance of any trait under study. Under general anesthesia, 39 mice received extraction of 3 right maxillary molar teeth and 28 mice received sham operation. On post-extraction day 21, post-mortem whole-brain high-resolution sMRI was used to quantify the volume of 160 brain regions. Compared to sham operation, tooth extraction was associated with a significantly reduced regional and voxel-wise volumes of cortical brain regions involved in processing somatosensory, motor, cognitive and emotional functions, and increased volumes in subcortical sensorimotor and temporal limbic forebrain regions including the amygdala. Additionally, comparison of the 10 BXA14

  15. Hepatosplenic volumetric assessment at MDCT for staging liver fibrosis.

    Science.gov (United States)

    Pickhardt, Perry J; Malecki, Kyle; Hunt, Oliver F; Beaumont, Claire; Kloke, John; Ziemlewicz, Timothy J; Lubner, Meghan G

    2017-07-01

    To investigate hepatosplenic volumetry at MDCT for non-invasive prediction of hepatic fibrosis. Hepatosplenic volume analysis in 624 patients (mean age, 48.8 years; 311 M/313 F) at MDCT was performed using dedicated software and compared against pathological fibrosis stage (F0 = 374; F1 = 48; F2 = 40; F3 = 65; F4 = 97). The liver segmental volume ratio (LSVR) was defined by Couinaud segments I-III over segments IV-VIII. All pre-cirrhotic fibrosis stages (METAVIR F1-F3) were based on liver biopsy within 1 year of MDCT. LSVR and total splenic volumes increased with stage of fibrosis, with mean(±SD) values of: F0: 0.26 ± 0.06 and 215.1 ± 88.5 mm(3); F1: 0.25 ± 0.08 and 294.8 ± 153.4 mm(3); F2: 0.331 ± 0.12 and 291.6 ± 197.1 mm(3); F3: 0.39 ± 0.15 and 509.6 ± 402.6 mm(3); F4: 0.56 ± 0.30 and 790.7 ± 450.3 mm(3), respectively. Total hepatic volumes showed poor discrimination (F0: 1674 ± 320 mm(3); F4: 1631 ± 691 mm(3)). For discriminating advanced fibrosis (≥F3), the ROC AUC values for LSVR, total liver volume, splenic volume and LSVR/spleen combined were 0.863, 0.506, 0.890 and 0.947, respectively. Relative changes in segmental liver volumes and total splenic volume allow for non-invasive staging of hepatic fibrosis, whereas total liver volume is a poor predictor. Unlike liver biopsy or elastography, these CT volumetric biomarkers can be obtained retrospectively on routine scans obtained for other indications. • Regional changes in hepatic volume (LSVR) correlate well with degree of fibrosis. • Total liver volume is a very poor predictor of underlying fibrosis. • Total splenic volume is associated with the degree of hepatic fibrosis. • Hepatosplenic volume assessment is comparable to elastography for staging fibrosis. • Unlike elastography, volumetric analysis can be performed retrospectively.

  16. Volumetric and MGMT parameters in glioblastoma patients: Survival analysis

    Directory of Open Access Journals (Sweden)

    Iliadis Georgios

    2012-01-01

    Full Text Available Abstract Background In this study several tumor-related volumes were assessed by means of a computer-based application and a survival analysis was conducted to evaluate the prognostic significance of pre- and postoperative volumetric data in patients harboring glioblastomas. In addition, MGMT (O6-methylguanine methyltransferase related parameters were compared with those of volumetry in order to observe possible relevance of this molecule in tumor development. Methods We prospectively analyzed 65 patients suffering from glioblastoma (GBM who underwent radiotherapy with concomitant adjuvant temozolomide. For the purpose of volumetry T1 and T2-weighted magnetic resonance (MR sequences were used, acquired both pre- and postoperatively (pre-radiochemotherapy. The volumes measured on preoperative MR images were necrosis, enhancing tumor and edema (including the tumor and on postoperative ones, net-enhancing tumor. Age, sex, performance status (PS and type of operation were also included in the multivariate analysis. MGMT was assessed for promoter methylation with Multiplex Ligation-dependent Probe Amplification (MLPA, for RNA expression with real time PCR, and for protein expression with immunohistochemistry in a total of 44 cases with available histologic material. Results In the multivariate analysis a negative impact was shown for pre-radiochemotherapy net-enhancing tumor on the overall survival (OS (p = 0.023 and for preoperative necrosis on progression-free survival (PFS (p = 0.030. Furthermore, the multivariate analysis confirmed the importance of PS in PFS and OS of patients. MGMT promoter methylation was observed in 13/23 (43.5% evaluable tumors; complete methylation was observed in 3/13 methylated tumors only. High rate of MGMT protein positivity (> 20% positive neoplastic nuclei was inversely associated with pre-operative tumor necrosis (p = 0.021. Conclusions Our findings implicate that volumetric parameters may have a significant role in

  17. DIFFERENTIAL ANALYSIS OF VOLUMETRIC STRAINS IN POROUS MATERIALS IN TERMS OF WATER FREEZING

    Directory of Open Access Journals (Sweden)

    Rusin Z.

    2013-06-01

    Full Text Available The paper presents the differential analysis of volumetric strain (DAVS. The method allows measurements of volumetric deformations of capillary-porous materials caused by water-ice phase change. The VSE indicator (volumetric strain effect, which under certain conditions can be interpreted as the minimum degree of phase change of water contained in the material pores, is proposed. The test results (DAVS for three materials with diversified microstructure: clinker brick, calcium-silicate brick and Portland cement mortar were compared with the test results for pore characteristics obtained with the mercury intrusion porosimetry.

  18. Is there a role for the use of volumetric cone beam computed tomography in periodontics?

    Science.gov (United States)

    du Bois, A H; Kardachi, B; Bartold, P M

    2012-03-01

    Volumetric computed cone beam tomography offers a number of significant advantages over conventional intraoral and extraoral panoramic radiography, as well as computed tomography. To date, periodontal diagnosis has relied heavily on the assessment of both intraoral radiographs and extraoral panoramic radiographs. With emerging technology in radiology there has been considerable interest in the role that volumetric cone beam computed tomography might play in periodontal diagnostics. This narrative reviews the current evidence and considers whether there is a role for volumetric cone beam computed tomography in periodontics.

  19. Parkinson's disease: diagnostic utility of volumetric imaging

    Energy Technology Data Exchange (ETDEWEB)

    Lin, Wei-Che; Chen, Meng-Hsiang [Kaohsiung Chang Gung Memorial Hospital and Chang Gung University College of Medicine, Department of Diagnostic Radiology, Kaohsiung (China); Chou, Kun-Hsien [National Yang-Ming University, Brain Research Center, Taipei (China); Lee, Pei-Lin [National Yang-Ming University, Department of Biomedical Imaging and Radiological Sciences, Taipei (China); Tsai, Nai-Wen; Lu, Cheng-Hsien [Kaohsiung Chang Gung Memorial Hospital and Chang Gung University College of Medicine, Department of Neurology, Kaohsiung (China); Chen, Hsiu-Ling [Kaohsiung Chang Gung Memorial Hospital and Chang Gung University College of Medicine, Department of Diagnostic Radiology, Kaohsiung (China); National Yang-Ming University, Department of Biomedical Imaging and Radiological Sciences, Taipei (China); Hsu, Ai-Ling [National Taiwan University, Institute of Biomedical Electronics and Bioinformatics, Taipei (China); Huang, Yung-Cheng [Kaohsiung Chang Gung Memorial Hospital and Chang Gung University College of Medicine, Department of Nuclear Medicine, Kaohsiung (China); Lin, Ching-Po [National Yang-Ming University, Brain Research Center, Taipei (China); National Yang-Ming University, Department of Biomedical Imaging and Radiological Sciences, Taipei (China)

    2017-04-15

    This paper aims to examine the effectiveness of structural imaging as an aid in the diagnosis of Parkinson's disease (PD). High-resolution T{sub 1}-weighted magnetic resonance imaging was performed in 72 patients with idiopathic PD (mean age, 61.08 years) and 73 healthy subjects (mean age, 58.96 years). The whole brain was parcellated into 95 regions of interest using composite anatomical atlases, and region volumes were calculated. Three diagnostic classifiers were constructed using binary multiple logistic regression modeling: the (i) basal ganglion prior classifier, (ii) data-driven classifier, and (iii) basal ganglion prior/data-driven hybrid classifier. Leave-one-out cross validation was used to unbiasedly evaluate the predictive accuracy of imaging features. Pearson's correlation analysis was further performed to correlate outcome measurement using the best PD classifier with disease severity. Smaller volume in susceptible regions is diagnostic for Parkinson's disease. Compared with the other two classifiers, the basal ganglion prior/data-driven hybrid classifier had the highest diagnostic reliability with a sensitivity of 74%, specificity of 75%, and accuracy of 74%. Furthermore, outcome measurement using this classifier was associated with disease severity. Brain structural volumetric analysis with multiple logistic regression modeling can be a complementary tool for diagnosing PD. (orig.)

  20. Volumetric Analysis of Regional Cerebral Development in Preterm Children

    Science.gov (United States)

    Kesler, Shelli R.; Ment, Laura R.; Vohr, Betty; Pajot, Sarah K.; Schneider, Karen C.; Katz, Karol H.; Ebbitt, Timothy B.; Duncan, Charles C.; Makuch, Robert W.; Reiss, Allan L.

    2011-01-01

    Preterm birth is frequently associated with both neuropathologic and cognitive sequelae. This study examined cortical lobe, subcortical, and lateral ventricle development in association with perinatal variables and cognitive outcome. High-resolution volumetric magnetic resonance imaging scans were acquired and quantified using advanced image processing techniques. Seventy-three preterm and 33 term control children ages 7.3-11.4 years were included in the study. Results indicated disproportionately enlarged parietal and frontal gray matter, occipital horn, and ventricular body, as well as reduced temporal and subcortical gray volumes in preterm children compared with control subjects. Birth weight was negatively correlated with parietal and frontal gray, as well as occipital horn volumes. Intraventricular hemorrhage was associated with reduced subcortical gray matter. Ventricular cerebrospinal fluid was negatively correlated with subcortical gray matter volumes but not with white matter volumes. Maternal education was the strongest predictor of cognitive function in the preterm group. Preterm birth appears to be associated with disorganized cortical development, possibly involving disrupted synaptic pruning and neural migration. Lower birth weight and the presence of intraventricular hemorrhage may increase the risk for neuroanatomic abnormality. PMID:15519112

  1. Volumetric microscale particle tracking velocimetry (PTV) in porous media

    Science.gov (United States)

    Guo, Tianqi; Aramideh, Soroush; Ardekani, Arezoo M.; Vlachos, Pavlos P.

    2016-11-01

    The steady-state flow through refractive-index-matched glass bead microchannels is measured using microscopic particle tracking velocimetry (μPTV). A novel technique is developed to volumetrically reconstruct particles from oversampled two-dimensional microscopic images of fluorescent particles. Fast oversampling of the quasi-steady-state flow field in the lateral direction is realized by a nano-positioning piezo stage synchronized with a fast CMOS camera. Experiments at different Reynolds numbers are carried out for flows through a series of both monodispersed and bidispersed glass bead microchannels with various porosities. The obtained velocity fields at pore-scale (on the order of 10 μm) are compared with direct numerical simulations (DNS) conducted in the exact same geometries reconstructed from micro-CT scans of the glass bead microchannels. The developed experimental method would serve as a new approach for exploring the flow physics at pore-scale in porous media, and also provide benchmark measurements for validation of numerical simulations.

  2. Buoyancy Driven Mixing with Continuous Volumetric Energy Deposition

    Science.gov (United States)

    Wachtor, Adam J.; Jebrail, Farzaneh F.; Dennisen, Nicholas A.; Andrews, Malcolm J.; Gore, Robert A.

    2014-11-01

    An experiment involving a miscible fluid pair is presented which transitioned from a Rayleigh-Taylor (RT) stable to RT unstable configuration through continuous volumetric energy deposition (VED) by microwave radiation. Initially a light, low microwave absorbing fluid rested above a heavier, more absorbing fluid. The alignment of the density gradient with gravity made the system stable, and the Atwood number (At) for the initial setup was approximately -0.12. Exposing the fluid pair to microwave radiation preferentially heated the bottom fluid, and caused its density to drop due to thermal expansion. As heating of the bottom fluid continued, the At varied from negative to positive, and after the system passed through the neutral stability point, At = 0, buoyancy driven mixing ensued. Continuous VED caused the At to continue increasing and further drive the mixing process. Successful VED mixing required careful design of the fluid pair used in the experiment. Therefore, fluid selection is discussed, along with challenges and limitations of data collection using the experimental microwave facility. Experimental and model predictions of the neutral stability point, and onset of buoyancy driven mixing, are compared, and differences with classical, constant At RT driven turbulence are discussed.

  3. Toward a Philosophy and Theory of Volumetric Nonthermal Processing.

    Science.gov (United States)

    Sastry, Sudhir K

    2016-06-01

    Nonthermal processes for food preservation have been under intensive investigation for about the past quarter century, with varying degrees of success. We focus this discussion on two volumetrically acting nonthermal processes, high pressure processing (HPP) and pulsed electric fields (PEF), with emphasis on scientific understanding of each, and the research questions that need to be addressed for each to be more successful in the future. We discuss the character or "philosophy" of food preservation, with a question about the nature of the kill step(s), and the sensing challenges that need to be addressed. For HPP, key questions and needs center around whether its nonthermal effectiveness can be increased by increased pressures or pulsing, the theoretical treatment of rates of reaction as influenced by pressure, the assumption of uniform pressure distribution, and the need for (and difficulties involved in) in-situ measurement. For PEF, the questions include the rationale for pulsing, difficulties involved in continuous flow treatment chambers, the difference between electroporation theory and experimental observations, and the difficulties involved in in-situ measurement and monitoring of electric field distribution.

  4. An MRI-based semiautomated volumetric quantification of hip osteonecrosis

    Energy Technology Data Exchange (ETDEWEB)

    Malizos, K.N.; Siafakas, M.S.; Karachalios, T.S. [Dept. of Orthopaedics, Univ. of Thessalia, Larissa (Greece); Fotiadis, D.I. [Dept. of Computer Science, Univ. of Ioannina (Greece); Soucacos, P.N. [Dept. of Orthopaedic Surgery, Univ. of Ioannina (Greece)

    2001-12-01

    Objective: To objectively and precisely define the spatial distribution of osteonecrosis and to investigate the influence of various factors including etiology. Design: A volumetric method is presented to describe the size and spatial distribution of necrotic lesions of the femoral head, using MRI scans. The technique is based on the definition of an equivalent sphere model for the femoral head. Patients: The gender, age, number of hips involved, disease duration, pain intensity, limping disability and etiology were correlated with the distribution of the pathologic bone. Seventy-nine patients with 122 hips affected by osteonecrosis were evaluated. Results: The lesion size ranged from 7% to 73% of the sphere equivalent. The lateral octants presented considerable variability, ranging from wide lateral lesions extending beyond the lip of the acetabulum, to narrow medial lesions, leaving a lateral supporting pillar of intact bone. Patients with sickle cell disease and steroid administration presented the largest lesions. The extent of the posterior superior medial octant involvement correlated with the symptom intensity, a younger age and male gender. Conclusion: The methodology presented here has proven a reliable and straightforward imaging tool for precise assessment of necrotic lesions. It also enables us to target accurately the drilling and grafting procedures. (orig.)

  5. Illustration-inspired depth enhanced volumetric medical visualization.

    Science.gov (United States)

    Svakhine, Nikolai A; Ebert, David S; Andrews, William M

    2009-01-01

    Volume illustration can be used to provide insight into source data from CT/MRI scanners in much the same way as medical illustration depicts the important details of anatomical structures. As such, proven techniques used in medical illustration should be transferable to volume illustration, providing scientists with new tools to visualize their data. In recent years, a number of techniques have been developed to enhance the rendering pipeline and create illustrative effects similar to the ones found in medical textbooks and surgery manuals. Such effects usually highlight important features of the subject while subjugating its context and providing depth cues for correct perception. Inspired by traditional visual and line-drawing techniques found in medical illustration, we have developed a collection of fast algorithms for more effective emphasis/de-emphasis of data as well as conveyance of spatial relationships. Our techniques utilize effective outlining techniques and selective depth enhancement to provide perceptual cues of object importance as well as spatial relationships in volumetric datasets. Moreover, we have used illustration principles to effectively combine and adapt basic techniques so that they work together to provide consistent visual information and a uniform style.

  6. Connectivity network measures predict volumetric atrophy in mild cognitive impairment.

    Science.gov (United States)

    Nir, Talia M; Jahanshad, Neda; Toga, Arthur W; Bernstein, Matt A; Jack, Clifford R; Weiner, Michael W; Thompson, Paul M

    2015-01-01

    Alzheimer's disease (AD) is characterized by cortical atrophy and disrupted anatomic connectivity, and leads to abnormal interactions between neural systems. Diffusion-weighted imaging (DWI) and graph theory can be used to evaluate major brain networks and detect signs of a breakdown in network connectivity. In a longitudinal study using both DWI and standard magnetic resonance imaging (MRI), we assessed baseline white-matter connectivity patterns in 30 subjects with mild cognitive impairment (MCI, mean age 71.8 ± 7.5 years, 18 males and 12 females) from the Alzheimer's Disease Neuroimaging Initiative. Using both standard MRI-based cortical parcellations and whole-brain tractography, we computed baseline connectivity maps from which we calculated global "small-world" architecture measures, including mean clustering coefficient and characteristic path length. We evaluated whether these baseline network measures predicted future volumetric brain atrophy in MCI subjects, who are at risk for developing AD, as determined by 3-dimensional Jacobian "expansion factor maps" between baseline and 6-month follow-up anatomic scans. This study suggests that DWI-based network measures may be a novel predictor of AD progression.

  7. Femoral head osteonecrosis: Volumetric MRI assessment and outcome

    Energy Technology Data Exchange (ETDEWEB)

    Bassounas, Athanasios E. [Department of Medical Physics, School of Medicine, University of Ioannina, GR 451 10 Ioannina (Greece); Karantanas, Apostolos H. [Department of Radiology, School of Medicine, University of Crete, Heraklion, GR 711 10 (Greece); Fotiadis, Dimitrios I. [Unit of Medical Technology and Intelligent Information Systems, Department of Computer Science, University of Ioannina and Biomedical Research Institute-FORTH, GR 451 10 Ioannina (Greece); Malizos, Konstantinos N. [Orthopaedic Department, Medical School, University of Thessalia, GR 412 22 Larissa (Greece)]. E-mail: kmalizos@otenet.gr

    2007-07-15

    Effective treatment of femoral head osteonecrosis (FHON) requires early diagnosis and accurate assessment of the disease severity. The ability to predict in the early stages the risk of collapse is important for selecting a joint salvage procedure. The aim of the present study was to evaluate the outcome in patients treated with vascularized fibular grafts in relation to preoperative MR imaging volumetry. We studied 58 patients (87 hips) with FHON. A semi-automated octant-based lesion measurement method, previously described, was performed on the T1-w MR images. The mean time of postoperative follow-up was 7.8 years. Sixty-three hips were successful and 24 failed and converted to total hip arthroplasty within a period of 2-4 years after the initial operation. The rate of failures for hips of male patients was higher than in female patients. The mean lesion size was 28% of the sphere equivalent of the femoral head, 24 {+-} 12% for the successful hips and 37 {+-} 9% for the failed (p < 0.001). The most affected octants were antero-supero-medial (58 {+-} 26%) and postero-supero-medial (54 {+-} 31%). All but postero-infero-medial and postero-infero-lateral octants, showed statistically significant differences in the lesion size between patients with successful and failed hips. In conclusion, the volumetric analysis of preoperative MRI provides useful information with regard to a successful outcome in patients treated with vascularized fibular grafts.

  8. Three-dimensional volumetric quantification of fat loss following cryolipolysis.

    Science.gov (United States)

    Garibyan, Lilit; Sipprell, William H; Jalian, H Ray; Sakamoto, Fernanda H; Avram, Mathew; Anderson, R Rox

    2014-02-01

    Cryolipolysis is a noninvasive and well-tolerated treatment for reduction of localized subcutaneous fat. Although several studies demonstrate the safety and efficacy of this procedure, volumetric fat reduction from this treatment has not been quantified. This prospective study investigated the change in volume of fat after cryolipolysis treatment using three-dimensional (3D) photography. A prospective study of subjects treated with cryolipolysis on the flank (love handle) was performed at Massachusetts General Hospital. Volume measurements were performed with a Canfield Scientific Vectra three-dimensional camera and software to evaluate the amount of post procedure volume change. Clinical outcomes were assessed with caliper measurements, subject surveys, and blinded physician assessment of photographs. Eleven subjects were enrolled in this study. Each subject underwent a single cycle of cryolipolysis to one flank. The untreated flank served as an internal control. The follow-up time after treatment was 2 months. The mean amount of calculated absolute fat volume loss using 3D photography from baseline to 2 months follow-up visit was 56.2 ± 25.6 from the treatment site and 16.6 ± 17.6 cc from the control (P fat removal methodology that on average leads to 39.6 cc of fat loss of the treated flank at 2 months after a single treatment cycle. © 2013 Wiley Periodicals, Inc.

  9. Cortical thickness and brain volumetric analysis in body dysmorphic disorder.

    Science.gov (United States)

    Madsen, Sarah K; Zai, Alex; Pirnia, Tara; Arienzo, Donatello; Zhan, Liang; Moody, Teena D; Thompson, Paul M; Feusner, Jamie D

    2015-04-30

    Individuals with body dysmorphic disorder (BDD) suffer from preoccupations with perceived defects in physical appearance, causing severe distress and disability. Although BDD affects 1-2% of the population, the neurobiology is not understood. Discrepant results in previous volumetric studies may be due to small sample sizes, and no study has investigated cortical thickness in BDD. The current study is the largest neuroimaging analysis of BDD. Participants included 49 medication-free, right-handed individuals with DSM-IV BDD and 44 healthy controls matched by age, sex, and education. Using high-resolution T1-weighted magnetic resonance imaging, we computed vertex-wise gray matter (GM) thickness on the cortical surface and GM volume using voxel-based morphometry. We also computed volumes in cortical and subcortical regions of interest. In addition to group comparisons, we investigated associations with symptom severity, insight, and anxiety within the BDD group. In BDD, greater anxiety was significantly associated with thinner GM in the left superior temporal cortex and greater GM volume in the right caudate nucleus. There were no significant differences in cortical thickness, GM volume, or volumes in regions of interest between BDD and control subjects. Subtle associations with clinical symptoms may characterize brain morphometric patterns in BDD, rather than large group differences in brain structure. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  10. Region-of-interest volumetric visual hull refinement

    KAUST Repository

    Knoblauch, Daniel

    2010-01-01

    This paper introduces a region-of-interest visual hull refinement technique, based on flexible voxel grids for volumetric visual hull reconstructions. Region-of-interest refinement is based on a multipass process, beginning with a focussed visual hull reconstruction, resulting in a first 3D approximation of the target, followed by a region-of-interest estimation, tasked with identifying features of interest, which in turn are used to locally refine the voxel grid and extract a higher-resolution surface representation for those regions. This approach is illustrated for the reconstruction of avatars for use in tele-immersion environments, where head and hand regions are of higher interest. To allow reproducability and direct comparison a publicly available data set for human visual hull reconstruction is used. This paper shows that region-of-interest reconstruction of the target is faster and visually comparable to higher resolution focused visual hull reconstructions. This approach reduces the amount of data generated through the reconstruction, allowing faster post processing, as rendering or networking of the surface voxels. Reconstruction speeds support smooth interactions between the avatar and the virtual environment, while the improved resolution of its facial region and hands creates a higher-degree of immersion and potentially impacts the perception of body language, facial expressions and eye-to-eye contact. Copyright © 2010 by the Association for Computing Machinery, Inc.

  11. A volumetric flow sensor for automotive injection systems

    Science.gov (United States)

    Schmid, U.; Krötz, G.; Schmitt-Landsiedel, D.

    2008-04-01

    For further optimization of the automotive power train of diesel engines, advanced combustion processes require a highly flexible injection system, provided e.g. by the common rail (CR) injection technique. In the past, the feasibility to implement injection nozzle volumetric flow sensors based on the thermo-resistive measurement principle has been demonstrated up to injection pressures of 135 MPa (1350 bar). To evaluate the transient behaviour of the system-integrated flow sensors as well as an injection amount indicator used as a reference method, hydraulic simulations on the system level are performed for a CR injection system. Experimentally determined injection timings were found to be in good agreement with calculated values, especially for the novel sensing element which is directly implemented into the hydraulic system. For the first time pressure oscillations occurring after termination of the injection pulse, predicted theoretically, could be verified directly in the nozzle. In addition, the injected amount of fuel is monitored with the highest resolution ever reported in the literature.

  12. Content Analysis

    National Research Council Canada - National Science Library

    Rossi, George Bedinelli; Serralvo, Francisco Antonio; João, Belmiro Nascimento

    2014-01-01

    This study introduces the various definitions and types of content analysis. This type of analysis historically presents itself as a quantitative approach to data analysis and currently shows up as a qualitative approach...

  13. Content Marketing

    OpenAIRE

    LE, DUC

    2013-01-01

    The purpose of this thesis was to introduce the new trend in today’s marketing world: content marketing. It has been employed by many companies and organizations in the world and has been proven success even when it is still a fairly new topic. Five carefully selected theories of content marketing proposed by experts in the field has been collected, compared and displayed as originally and scientifically as possible in this thesis. The chosen theories provide a diversified perspectives of...

  14. Enhanced oil recovery by surfactant-enhanced volumetric sweep efficiency: Second annual report, September 30, 1986-September 30, 1987

    Energy Technology Data Exchange (ETDEWEB)

    Harwell, J H; Scamehorn, J F

    1988-04-01

    It is widely known that heterogeneities in oil reservoirs occurring as a result of permeability variations in the rock can have a detrimental effect on an oil recovery process; preferential diversion of injected displacement fluid occurs through the high-permeability zones, leaving the lower-permeability zones at a high residual oil content at a time when it is no longer economically viable to continue the oil recovery process. A novel oil recovery process is described which aims to improve the volumetric sweep efficiency of oil recovery. High-permeability zones are partially or completely plugged off by using the chromatographic and phase behavior of surfactants and their mixtures and the preferential invasion of high-permeability areas by low-viscosity injected fluids. The plugging will divert flow into regions of higher oil saturation. 85 refs., 46 figs., 6 tabs.

  15. Effect of polyphenol oxidase (PPO and air treatments on total phenol and tannin content of cocoa nibs Efeito dos tratamentos com polifenol oxidase (PPO e ar sobre o teor de fenóis totais e taninos em nibs de cacau

    Directory of Open Access Journals (Sweden)

    Edy Sousa de Brito

    2002-01-01

    Full Text Available Cocoa flavour is greatly influenced by polyphenols. These compounds undergo a series of transformations during cocoa processing leading to the characteristic cocoa flavour. The use of exogenous polyphenol oxidase (PPO proved to be useful to reduce polyphenol content in cocoa nibs. The effect of a PPO associated or not with air over total phenol and tannin content was evaluated. Cocoa nibs were autoclaved and treated with a PPO or water in the absence or presence of an air flow for 0.5, 1, 2 and 3 hours. Total phenol content was reduced in PPO or water treatments, but when associated with air there was an increase in phenol content. Tannin content was reduced only by the treatment with water and air.O sabor do cacau é fortemente influenciado pelos polifenóis. Esses compostos sofrem uma série de transformações durante o processamento do cacau dando origem ao sabor característico do cacau. O uso de polifenol oxidase (PPO exógena mostrou ser útil na redução do teor de polifenóis em nibs de cacau. O efeito de uma PPO associada ou não com ar sobre o teor de fenóis totais e taninos foi avaliado. Nibs de cacau foram autoclavados e tratados com PPO ou água na presença ou não de um fluxo de ar por 0,5; 1; 2 e 3 horas. O teor de fenóis totais foi reduzido nos tratamentos com PPO ou água, mas quando associados com ar houve um aumento desses teores. O teor de taninos foi reduzido apenas pelo tratamento com água e ar.

  16. Volumetric study of the olfactory bulb in patients with chronic rhinonasal sinusitis using MRI

    Directory of Open Access Journals (Sweden)

    Reda A. Alarabawy

    2016-06-01

    Conclusions: MRI with volumetric analysis is a useful tool in assessment of the olfactory bulb volume in patients with olfactory loss and appears to be of help in assessment of the degree of recovery in patients after sinus surgery.

  17. Inkjet printing-based volumetric display projecting multiple full-colour 2D patterns

    Science.gov (United States)

    Hirayama, Ryuji; Suzuki, Tomotaka; Shimobaba, Tomoyoshi; Shiraki, Atsushi; Naruse, Makoto; Nakayama, Hirotaka; Kakue, Takashi; Ito, Tomoyoshi

    2017-04-01

    In this study, a method to construct a full-colour volumetric display is presented using a commercially available inkjet printer. Photoreactive luminescence materials are minutely and automatically printed as the volume elements, and volumetric displays are constructed with high resolution using easy-to-fabricate means that exploit inkjet printing technologies. The results experimentally demonstrate the first prototype of an inkjet printing-based volumetric display composed of multiple layers of transparent films that yield a full-colour three-dimensional (3D) image. Moreover, we propose a design algorithm with 3D structures that provide multiple different 2D full-colour patterns when viewed from different directions and experimentally demonstrate prototypes. It is considered that these types of 3D volumetric structures and their fabrication methods based on widely deployed existing printing technologies can be utilised as novel information display devices and systems, including digital signage, media art, entertainment and security.

  18. Mechanical properties, volumetric shrinkage and depth of cure of short fiber-reinforced resin composite.

    Science.gov (United States)

    Tsujimoto, Akimasa; Barkmeier, Wayne W; Takamizawa, Toshiki; Latta, Mark A; Miyazaki, Masashi

    2016-01-01

    The mechanical properties, volumetric shrinkage and depth of cure of a short fiber-reinforced resin composite (SFRC) were investigated in this study and compared to both a bulk fill resin composite (BFRC) and conventional glass/ceramic-filled resin composite (CGRC). Fracture toughness, flexural properties, volumetric shrinkage and depth of cure of the SFRC, BFRC and CGRC were measured. SFRC had significantly higher fracture toughness than BFRCs and CGRCs. The flexural properties of SFRC were comparable with BFRCs and CGRCs. SFRC showed significantly lower volumetric shrinkage than the other tested resin composites. The depth of cure of the SFRC was similar to BFRCs and higher than CGRCs. The data from this laboratory investigation suggests that SFRC exhibits improvements in fracture toughness, volumetric shrinkage and depth of cure when compared with CGRC, but depth of cure of SFRC was similar to BFRC.

  19. Review of prospects and challenges of eye tracking in volumetric imaging.

    Science.gov (United States)

    Venjakob, Antje C; Mello-Thoms, Claudia R

    2016-01-01

    While eye tracking research in conventional radiography has flourished over the past decades, the number of eye tracking studies that looked at multislice images lags behind. A possible reason for the lack of studies in this area might be that the eye tracking methodology used in the context of conventional radiography cannot be applied one-on-one to volumetric imaging material. Challenges associated with eye tracking in volumetric imaging are particularly associated with the selection of stimulus material, the detection of events in the eye tracking data, the calculation of meaningful eye tracking parameters, and the reporting of abnormalities. However, all of these challenges can be addressed in the design of the experiment. If this is done, eye tracking studies using volumetric imaging material offer almost unlimited opportunity for perception research and are highly relevant as the number of volumetric images that are acquired and interpreted is rising.

  20. Development of new volumetric compressor with rotating cylinder and piston

    Energy Technology Data Exchange (ETDEWEB)

    Sawai, K.; Iida, N.; Futagami, Y.; Hirano, H. [Matsushita Electrical Ind. Co. Ltd., Air-Conditioning Research Lab., Shiga (Japan); Hasegawa, H. [Matsushita Electric Ind. Co. Ltd., Human Environment Systems Development Center, Osaka (Japan); Ishii, N. [Osaka Electro-Communications Lab., Faculty of Engineering, Osaka (Japan)

    1999-07-01

    We developed a new compression mechanism named 'Ellipse Compressor', which can be used in air conditioning and refrigeration. This compression mechanism is basically rotary type machine, which consists of rotating cylinder and rotating piston without vane. It has high potentiality to exhibit high reliability in R410A refrigerant, because of low wear without extreme high pressure on the sliding parts. This paper presents a compression mechanism, theoretical analysis, a prototype model design, performance and loss analysis. Test results indicated that the performance of the prototype model exhibited almost the same as that of scroll compressor for room air conditioner. Durability test on the room air conditioner at heavy heating condition resulted in the low level of wear of the sliding parts, without special materials. (Author)

  1. Planning strategies in volumetric modulated are therapy for breast.

    Science.gov (United States)

    Giorgia, Nicolini; Antonella, Fogliata; Alessandro, Clivio; Eugenio, Vanetti; Luca, Cozzi

    2011-07-01

    In breast radiotherapy with intensity modulation, it is a well established practice to extend the dose fluence outside the limit of the body contour to account for small changes in size and position of the target and the rest of the tissues due to respiration or to possible oedema. A simple approach is not applicable with RapidArc volumetric modulated are therapy not being based on a fixed field fluence delivery. In this study, a viable technical strategy to account for this need is presented. RapidArc (RA) plans for six breast cancer patients (three right and three left cases), were optimized (PRO version III) on the original CT data set (0) and on an alternative CT (E) generated with an artificial expansion (and assignment of soft-tissue equivalent HU) of 10 mm of the body in the breast region and of the PTV contours toward the external direction. Final dose calculations for the two set of plans were performed on the same original CT data set O, normalizing the dose prescription (50 Gy) to the target mean. In this way, two treatment plans on the same CT set O for each patient were obtained: the no action plan (OO) and the alternative plan based on an expanded optimization (EO). Fixing MU, these two plans were then recomputed on the expanded CT data set and on an intermediate one (with expansion = 5 mm), to mimic, possible changes in size due to edema during treatment or residual displacements due to breathing not properly controlled. Aim of the study was to quantify the robustness of this planning strategy on dose distributions when either the OO or the EO strategies were adopted. For all the combinations, a DVH analysis of all involved structures is reported. I. The two optimization approaches gave comparable dose distributions on the original CT data set. II. When plans were evaluated on the expanded CTs (mimicking the presence of edema), the EO approach showed improved target coverage if compared to OO: on CT_10 mm, Dv = 98% [%]= 92.5 +/- 0.9 and 68.5 +/- 3

  2. Planning strategies in volumetric modulated arc therapy for breast.

    Science.gov (United States)

    Nicolini, Giorgia; Fogliata, Antonella; Clivio, Alessandro; Vanetti, Eugenio; Cozzi, Luca

    2011-07-01

    In breast radiotherapy with intensity modulation, it is a well established practice to extend the dose fluence outside the limit of the body contour to account for small changes in size and position of the target and the rest of the tissues due to respiration or to possible oedema. A simple approach is not applicable with RapidArc volumetric modulated arc therapy not being based on a fixed field fluence delivery. In this study, a viable technical strategy to account for this need is presented. RapidArc (RA) plans for six breast cancer patients (three right and three left cases), were optimized (PRO version III) on the original CT data set (O) and on an alternative CT (E) generated with an artificial expansion (and assignment of soft-tissue equivalent HU) of 10 mm of the body in the breast region and of the PTV contours toward the external direction. Final dose calculations for the two set of plans were performed on the same original CT data set O, normalizing the dose prescription (50 Gy) to the target mean. In this way, two treatment plans on the same CT set O for each patient were obtained: the no action plan (OO) and the alternative plan based on an expanded optimization (EO). Fixing MU, these two plans were then recomputed on the expanded CT data set and on an intermediate one (with expansion = 5 mm), to mimic, possible changes in size due to edema during treatment or residual displacements due to breathing not properly controlled. Aim of the study was to quantify the robustness of this planning strategy on dose distributions when either the OO or the EO strategies were adopted. For all the combinations, a DVH analysis of all involved structures is reported. I. The two optimization approaches gave comparable dose distributions on the original CT data set. II. When plans were evaluated on the expanded CTs (mimicking the presence of edema), the EO approach showed improved target coverage if compared to OO: on CT_10 mm, DV = 98% [%] = 92.5 ± 0

  3. Volumetric Properties of the Mixture Tetrachloromethane CCl4 + CHCl3 Trichloromethane (VMSD1212, LB4576_V)

    Science.gov (United States)

    Cibulka, I.; Fontaine, J.-C.; Sosnkowska-Kehiaian, K.; Kehiaian, H. V.

    This document is part of Subvolume C 'Binary Liquid Systems of Nonelectrolytes III' of Volume 26 'Heats of Mixing, Vapor-Liquid Equilibrium, and Volumetric Properties of Mixtures and Solutions' of Landolt-Börnstein Group IV 'Physical Chemistry'. It contains the Chapter 'Volumetric Properties of the Mixture Tetrachloromethane CCl4 + CHCl3 Trichloromethane (VMSD1212, LB4576_V)' providing data by calculation of molar excess volume from low-pressure density measurements at variable mole fraction and constant temperature.

  4. Determination of ferrous iron in rock and mineral samples by three volumetric methods

    OpenAIRE

    Saikkonen, R.J.; Rautiainen, I.A.

    1993-01-01

    Ferrous iron was determined by three volumetric methods in 13 in-house reference rock samples and in 31 international geological reference samples. The methods used were Amonette & Scott' s oxidimetric method, Wilson's oxidimetric method and Pratt's method. The results for FeO by these volumetric methods in 13 in-house rock samples were compared to the results obtained in other analytical laboratories in Finland. The results for FeO in the international samples were compared with published da...

  5. FEMUR SHAPE RECOVERY FROM VOLUMETRIC IMAGES USING 3-D DEFORMABLE MODELS

    Institute of Scientific and Technical Information of China (English)

    2000-01-01

    A new scheme for femur shape recovery from volumetric images using deformable models was proposed. First, prior 3-D deformable femur models are created as templates using point distribution models technology. Second, active contour models are employed to segment the magnetic resonance imaging (MRI) volumetric images of the tibial and femoral joints and the deformable models are initialized based on the segmentation results. Finally, the objective function is minimized to give the optimal results constraining the surface of shapes.

  6. Understanding Volumetric and Gravimetric Hydrogen Adsorption Trade-off in Metal-Organic Frameworks.

    Science.gov (United States)

    Gómez-Gualdrón, Diego A; Wang, Timothy C; García-Holley, Paula; Sawelewa, Ruth M; Argueta, Edwin; Snurr, Randall Q; Hupp, Joseph T; Yildirim, Taner; Farha, Omar K

    2017-04-07

    Metal-organic frameworks (MOFs) are porous crystalline materials that are promising for adsorption-based, on-board storage of hydrogen in fuel-cell vehicles. Volumetric and gravimetric hydrogen capacities are the key factors that determine the size and weight of the MOF-filled tank required to store a certain amount of hydrogen for reasonable driving range. Therefore, they must be optimized so the tank is neither too large nor too heavy. Because the goals of maximizing MOF volumetric and gravimetric hydrogen adsorption loadings individually are incompatible, an in-depth understanding of the trade-off between MOF volumetric and gravimetric loadings is necessary to achieve the best compromise between these properties. Here we study, both experimentally and computationally, the trade-off between volumetric and gravimetric cryo-adsorbed hydrogen deliverable capacity by taking an isoreticular series of highly stable zirconium MOFs, NU-1101, NU-1102, and NU-1103 as a case study. These MOFs were studied under recently proposed operating conditions: 77 K/100 bar →160 K/5 bar. We found the difference between highest and lowest measured deliverable capacity in the MOF series to be ca. 40% gravimetrically, but only ca. 10% volumetrically. From our molecular simulation results, we found hydrogen "monolayer" adsorption to be proportional to the surface area, whereas hydrogen "pore filling" adsorption is proportional to the pore volume. Thus, we found that the higher variability in gravimetric deliverable capacity in contrast to the volumetric capacity, occurs due to the proportional relation between gravimetric surface area and pore volume in the NU-110x series in contrast to the inverse relation between volumetric surface area and void fraction. Additionally, we find better correlations with geometric surface areas than with BET areas. NU-1101 presents the highest measured volumetric performance with 46.6 g/L (9.1 wt %), whereas NU-1103 presents the highest gravimetric one

  7. Optimization of volumetric breast density estimation in digital mammograms.

    Science.gov (United States)

    Holland, Katharina; Gubern-Mérida, Albert; Mann, Ritse M; Karssemeijer, Nico

    2017-05-07

    Fibroglandular tissue volume and percent density can be estimated in unprocessed mammograms using a physics-based method, which relies on an internal reference value representing the projection of fat only. However, pixels representing fat only may not be present in dense breasts, causing an underestimation of density measurements. In this work, we investigate alternative approaches for obtaining a tissue reference value to improve density estimations, particularly in dense breasts. Two of three investigated reference values (F1, F2) are percentiles of the pixel value distribution in the breast interior (the contact area of breast and compression paddle). F1 is determined in a small breast interior, which minimizes the risk that peripheral pixels are included in the measurement at the cost of increasing the chance that no proper reference can be found. F2 is obtained using a larger breast interior. The new approach which is developed for very dense breasts does not require the presence of a fatty tissue region. As reference region we select the densest region in the mammogram and assume that this represents a projection of entirely dense tissue embedded between the subcutaneous fatty tissue layers. By measuring the thickness of the fat layers a reference (F3) can be computed. To obtain accurate breast density estimates irrespective of breast composition we investigated a combination of the results of the three reference values. We collected 202 pairs of MRI's and digital mammograms from 119 women. We compared the percent dense volume estimates based on both modalities and calculated Pearson's correlation coefficients. With the references F1-F3 we found respectively a correlation of [Formula: see text], [Formula: see text] and [Formula: see text]. Best results were obtained with the combination of the density estimations ([Formula: see text]). Results show that better volumetric density estimates can be obtained with the hybrid method, in particular for dense

  8. Semiautomatic segmentation of liver metastases on volumetric CT images

    Energy Technology Data Exchange (ETDEWEB)

    Yan, Jiayong [Department of Biomedical Engineering, Shanghai University of Medicine & Health Sciences, 101 Yingkou Road, Yang Pu District, Shanghai 200093 (China); Schwartz, Lawrence H.; Zhao, Binsheng, E-mail: bz2166@cumc.columbia.edu [Department of Radiology, Columbia University Medical Center, 630 West 168th Street, New York, New York 10032 (United States)

    2015-11-15

    Purpose: Accurate segmentation and quantification of liver metastases on CT images are critical to surgery/radiation treatment planning and therapy response assessment. To date, there are no reliable methods to perform such segmentation automatically. In this work, the authors present a method for semiautomatic delineation of liver metastases on contrast-enhanced volumetric CT images. Methods: The first step is to manually place a seed region-of-interest (ROI) in the lesion on an image. This ROI will (1) serve as an internal marker and (2) assist in automatically identifying an external marker. With these two markers, lesion contour on the image can be accurately delineated using traditional watershed transformation. Density information will then be extracted from the segmented 2D lesion and help determine the 3D connected object that is a candidate of the lesion volume. The authors have developed a robust strategy to automatically determine internal and external markers for marker-controlled watershed segmentation. By manually placing a seed region-of-interest in the lesion to be delineated on a reference image, the method can automatically determine dual threshold values to approximately separate the lesion from its surrounding structures and refine the thresholds from the segmented lesion for the accurate segmentation of the lesion volume. This method was applied to 69 liver metastases (1.1–10.3 cm in diameter) from a total of 15 patients. An independent radiologist manually delineated all lesions and the resultant lesion volumes served as the “gold standard” for validation of the method’s accuracy. Results: The algorithm received a median overlap, overestimation ratio, and underestimation ratio of 82.3%, 6.0%, and 11.5%, respectively, and a median average boundary distance of 1.2 mm. Conclusions: Preliminary results have shown that volumes of liver metastases on contrast-enhanced CT images can be accurately estimated by a semiautomatic segmentation

  9. Blockwise conjugate gradient methods for image reconstruction in volumetric CT.

    Science.gov (United States)

    Qiu, W; Titley-Peloquin, D; Soleimani, M

    2012-11-01

    Cone beam computed tomography (CBCT) enables volumetric image reconstruction from 2D projection data and plays an important role in image guided radiation therapy (IGRT). Filtered back projection is still the most frequently used algorithm in applications. The algorithm discretizes the scanning process (forward projection) into a system of linear equations, which must then be solved to recover images from measured projection data. The conjugate gradients (CG) algorithm and its variants can be used to solve (possibly regularized) linear systems of equations Ax=b and linear least squares problems minx∥b-Ax∥2, especially when the matrix A is very large and sparse. Their applications can be found in a general CT context, but in tomography problems (e.g. CBCT reconstruction) they have not widely been used. Hence, CBCT reconstruction using the CG-type algorithm LSQR was implemented and studied in this paper. In CBCT reconstruction, the main computational challenge is that the matrix A usually is very large, and storing it in full requires an amount of memory well beyond the reach of commodity computers. Because of these memory capacity constraints, only a small fraction of the weighting matrix A is typically used, leading to a poor reconstruction. In this paper, to overcome this difficulty, the matrix A is partitioned and stored blockwise, and blockwise matrix-vector multiplications are implemented within LSQR. This implementation allows us to use the full weighting matrix A for CBCT reconstruction without further enhancing computer standards. Tikhonov regularization can also be implemented in this fashion, and can produce significant improvement in the reconstructed images.

  10. Application of AAPM TG 119 to volumetric arc therapy (VMAT).

    Science.gov (United States)

    Mynampati, Dinesh Kumar; Yaparpalvi, Ravindra; Hong, Linda; Kuo, Hsiang-Chi; Mah, Dennis

    2012-09-06

    The purpose of this study was to create AAPM TG 119 benchmark plans for volumetric arc therapy (VMAT) and to compare VMAT plans with IMRT plan data. AAPM TG 119 proposes a set of test clinical cases for testing the accuracy of IMRT planning and delivery system. For these test cases, we generated two treatment plans, the first plan using 7-9 static dMLC IMRT fields and a second plan utilizing one- or two-arc VMAT technique. Dose optimization and calculations performed using 6 MV photons and Eclipse treatment planning system. Dose prescription and planning objectives were set according to the TG 119 goals. Plans were scored based on TG 119 planning objectives. Treatment plans were compared using conformity index (CI) for reference dose and homogeneity index (HI) (for D(5)-D(95)). For test cases prostate, head-and-neck, C-shape and multitarget prescription dose are 75.6 Gy, 50.4 Gy, 50 Gy and 50 Gy, respectively. VMAT dose distributions were comparable to dMLC IMRT plans. Our planning results matched TG 119 planning results. For treatment plans studied, conformity indices ranged from 1.05-1.23 (IMRT) and 1.04-1.23 (VMAT). Homogeneity indices ranged from 4.6%-11.0% (IMRT) and 4.6%-10.5% (VMAT). The ratio of total monitor units necessary for dMLC IMRT to that of VMAT was in the range of 1.1-2.0. AAPM TG 119 test cases are useful to generate VMAT benchmark plans. At preclinical implementation stage, plan comparison of VMAT and IMRT plans of AAPM TG 119 test case allowed us to understand basic capabilities of VMAT technique.

  11. Mammographic density estimation with automated volumetric breast density measurement.

    Science.gov (United States)

    Ko, Su Yeon; Kim, Eun-Kyung; Kim, Min Jung; Moon, Hee Jung

    2014-01-01

    To compare automated volumetric breast density measurement (VBDM) with radiologists' evaluations based on the Breast Imaging Reporting and Data System (BI-RADS), and to identify the factors associated with technical failure of VBDM. In this study, 1129 women aged 19-82 years who underwent mammography from December 2011 to January 2012 were included. Breast density evaluations by radiologists based on BI-RADS and by VBDM (Volpara Version 1.5.1) were compared. The agreement in interpreting breast density between radiologists and VBDM was determined based on four density grades (D1, D2, D3, and D4) and a binary classification of fatty (D1-2) vs. dense (D3-4) breast using kappa statistics. The association between technical failure of VBDM and patient age, total breast volume, fibroglandular tissue volume, history of partial mastectomy, the frequency of mass > 3 cm, and breast density was analyzed. The agreement between breast density evaluations by radiologists and VBDM was fair (k value = 0.26) when the four density grades (D1/D2/D3/D4) were used and moderate (k value = 0.47) for the binary classification (D1-2/D3-4). Twenty-seven women (2.4%) showed failure of VBDM. Small total breast volume, history of partial mastectomy, and high breast density were significantly associated with technical failure of VBDM (p = 0.001 to 0.015). There is fair or moderate agreement in breast density evaluation between radiologists and VBDM. Technical failure of VBDM may be related to small total breast volume, a history of partial mastectomy, and high breast density.

  12. Environmental Consequences of Volumetric Traffic Flow in Calabar ...

    African Journals Online (AJOL)

    User

    2011-05-20

    May 20, 2011 ... This paper seek to examined the environmental consequences of ... shows that there is a positive relationship between air pollutants ... The climate of the study area is of the semi-equatorial (monsoonal) type ... Literature Review ... of transport in Nigeria on the one hand while changing attitude and rise in.

  13. Quantitative prediction of respiratory tidal volume based on the external torso volume change: a potential volumetric surrogate

    Energy Technology Data Exchange (ETDEWEB)

    Li Guang; Arora, Naveen C; Xie Huchen; Ning, Holly; Citrin, Deborah; Kaushal, Aradhana; Zach, Leor; Camphausen, Kevin; Miller, Robert W [Radiation Oncology Branch, National Cancer Institute, National Institutes of Health, Bethesda, MD 20892 (United States); Lu Wei; Low, Daniel [Department of Radiation Oncology, Washington University School of Medicine, St Louis, MO 63110 (United States)], E-mail: ligeorge@mail.nih.gov

    2009-04-07

    An external respiratory surrogate that not only highly correlates with but also quantitatively predicts internal tidal volume should be useful in guiding four-dimensional computed tomography (4DCT), as well as 4D radiation therapy (4DRT). A volumetric surrogate should have advantages over external fiducial point(s) for monitoring respiration-induced motion of the torso, which deforms in synchronization with a patient-specific breathing pattern. This study establishes a linear relationship between the external torso volume change (TVC) and lung air volume change (AVC) by validating a proposed volume conservation hypothesis (TVC = AVC) throughout the respiratory cycle using 4DCT and spirometry. Fourteen patients' torso 4DCT images and corresponding spirometric tidal volumes were acquired to examine this hypothesis. The 4DCT images were acquired using dual surrogates in cine mode and amplitude-based binning in 12 respiratory stages, minimizing residual motion artifacts. Torso and lung volumes were calculated using threshold-based segmentation algorithms and volume changes were calculated relative to the full-exhalation stage. The TVC and AVC, as functions of respiratory stages, were compared, showing a high correlation (r = 0.992 {+-} 0.005, p < 0.0001) as well as a linear relationship (slope = 1.027 {+-} 0.061, R{sup 2} = 0.980) without phase shift. The AVC was also compared to the spirometric tidal volumes, showing a similar linearity (slope = 1.030 {+-} 0.092, R{sup 2} = 0.947). In contrast, the thoracic and abdominal heights measured from 4DCT showed relatively low correlation (0.28 {+-} 0.44 and 0.82 {+-} 0.30, respectively) and location-dependent phase shifts. This novel approach establishes the foundation for developing an external volumetric respiratory surrogate.

  14. 空分设备分子筛纯化系统出口空气中二氧化碳含量超标分析与处理%Analysis and treatment of exceedance of carbon dioxide content in outlet air of molecular sieve purification system of

    Institute of Scientific and Technical Information of China (English)

    张振友

    2011-01-01

    分子筛纯化系统出口空气中二氧化碳含量超标是影响空分设备稳定运行的主要因素之一。文章从分子筛纯化系统加工气体质量,设计制造,安装操作以及分子筛本身性能4方面,综合分析了导致二氧化碳含量超标的根本原因和处理措施。%The exceedance of carbon dioxide content in outlet air of molecular sieve purification system in one of main factors impairing the stable run of air separation plant. Here, the essential causes for the said exceedance of carbon dioxide content are compreh

  15. Analysis and treatment of over-standard carbon dioxide content in the outlet air from molecular sieve adsorber in the larger scale ASU%大型空分设备分子筛出口空气中CO2含量超标分析与处理

    Institute of Scientific and Technical Information of China (English)

    韩磊; 孙瑞

    2015-01-01

    介绍分子筛吸附器出口空气中二氧化碳含量超标,采取优化操作手段,但仍未消除故障,相反,分子筛出口空气中二氧化碳含量继续升高.立即对该套空分进行停机处理,分子筛检修后运行正常.%The phenomena of over-standard carbon dioxide content in the outlet air from molecular sieve adsorber is Introduced. The optimizing operation means were failed to eliminate the fault, however, the carbon dioxide content in the outlet air from molecular sieve adsorber was continue to rise. This ASU was shut down immediately. The molecular sieve adsorber was operating normally after maintenance.

  16. Effect of MgO Additive on Volumetric Expansion of Self-Degradable Cements

    Energy Technology Data Exchange (ETDEWEB)

    Sugama T.; Warren, J.; Butcher, T.

    2011-09-30

    We identified hard-burned magnesium oxide (MgO) as a suitable expansive additive for improving the plugging performance of self-degradable, temporary sodium silicate-activated slag/Class C fly ash (SSASC) blend cement sealers into rock fractures in Enhanced Geothermal Systems (EGSs). MgO extended the volumetric expansion of sealers during their exposure to a hydrothermal environment at 200 C under pressures, ranging from 300 to 1500 psi. A great expansion ratc of 19.3% was observed by adding 3.0 wt% MgO under 300 psi pressure, thus promising to plug thoroughly inner fracture. When the pressure was increased from 300 psi to 1500 psi, the expansion rate of cement markedly reduced, corresponding to the formaLion of crack-free specimens and the improvement of compressive strength. However, with 3.0 wt% MgO, the specimens still engendered the generation of numerous visual cracks, although they were prepared under a high pressure of 1500 psi. The effective content of MgO in minimizing and eliminating the generation of cracks was 2.0 wt%, which provided a moderate expansion of {ge} 0.5%. The compressive strength of 2.0 wt% MgO specimens made under a pressure of 300 psi rose {approx} 1.7-fold to 4816 psi with an increasing pressure to 1500 psi. The in-situ growth of brucite crystal formed by the hydrothermal hydration of MgO was responsive for such an expansion of the SSASC cement; meanwhile. two crystalline hydrothermal reaction products, 1.1 nm tobermorite and calcium silicate hydrated, contributed to the development of the sealer's compressive strength. Thus, the increasing pressure seems to suppress and control a growth rate of brucite crystal in response to a lower extension of expansion. Furthermore, all MgO-conlaining SSASC sealers possessed the water-catalyzed self-degradable properties.

  17. Effect of MgO Additive on Volumetric Expansion of Self-Degradable Cements

    Energy Technology Data Exchange (ETDEWEB)

    Sugama T.; Warren, J.; Butcher, T.

    2011-09-30

    We identified hard-burned magnesium oxide (MgO) as a suitable expansive additive for improving the plugging performance of self-degradable, temporary sodium silicate-activated slag/Class C fly ash (SSASC) blend cement sealers into rock fractures in Enhanced Geothermal Systems (EGSs). MgO extended the volumetric expansion of sealers during their exposure to a hydrothermal environment at 200 C under pressures, ranging from 300 to 1500 psi. A great expansion ratc of 19.3% was observed by adding 3.0 wt% MgO under 300 psi pressure, thus promising to plug thoroughly inner fracture. When the pressure was increased from 300 psi to 1500 psi, the expansion rate of cement markedly reduced, corresponding to the formaLion of crack-free specimens and the improvement of compressive strength. However, with 3.0 wt% MgO, the specimens still engendered the generation of numerous visual cracks, although they were prepared under a high pressure of 1500 psi. The effective content of MgO in minimizing and eliminating the generation of cracks was 2.0 wt%, which provided a moderate expansion of {ge} 0.5%. The compressive strength of 2.0 wt% MgO specimens made under a pressure of 300 psi rose {approx} 1.7-fold to 4816 psi with an increasing pressure to 1500 psi. The in-situ growth of brucite crystal formed by the hydrothermal hydration of MgO was responsive for such an expansion of the SSASC cement; meanwhile. two crystalline hydrothermal reaction products, 1.1 nm tobermorite and calcium silicate hydrated, contributed to the development of the sealer's compressive strength. Thus, the increasing pressure seems to suppress and control a growth rate of brucite crystal in response to a lower extension of expansion. Furthermore, all MgO-conlaining SSASC sealers possessed the water-catalyzed self-degradable properties.

  18. A Technique for Generating Volumetric Cine MRI (VC-MRI)

    Science.gov (United States)

    Harris, Wendy; Ren, Lei; Cai, Jing; Zhang, You; Chang, Zheng; Yin, Fang-Fang

    2016-01-01

    Purpose To develop a technique to generate on-board volumetric-cine MRI (VC-MRI) using patient prior images, motion modeling and on-board 2D-cine MRI. Methods One phase of a 4D-MRI acquired during patient simulation is used as patient prior images. 3 major respiratory deformation patterns of the patient are extracted from 4D-MRI based on principal-component-analysis. The on-board VC-MRI at any instant is considered as a deformation of the prior MRI. The deformation field is represented as a linear combination of the 3 major deformation patterns. The coefficients of the deformation patterns are solved by the data fidelity constraint using the acquired on-board single 2D-cine MRI. The method was evaluated using both XCAT simulation of lung cancer patients and MRI data from four real liver cancer patients. The accuracy of the estimated VC-MRI was quantitatively evaluated using Volume-Percent-Difference(VPD), Center-of-Mass-Shift(COMS), and target tracking errors. Effects of acquisition orientation, region-of-interest(ROI) selection, patient breathing pattern change and noise on the estimation accuracy were also evaluated. Results Image subtraction of ground-truth with estimated on-board VC-MRI shows fewer differences than image subtraction of ground-truth with prior image. Agreement between profiles in the estimated and ground-truth VC-MRI was achieved with less than 6% error for both XCAT and patient data. Among all XCAT scenarios, the VPD between ground-truth and estimated lesion volumes was on average 8.43±1.52% and the COMS was on average 0.93±0.58mm across all time-steps for estimation based on the ROI region in the sagittal cine images. Matching to ROI in the sagittal view achieved better accuracy when there was substantial breathing pattern change. The technique was robust against noise levels up to SNR=20. For patient data, average tracking errors were less than 2 mm in all directions for all patients. Conclusions Preliminary studies demonstrated the

  19. A Technique for Generating Volumetric Cine-Magnetic Resonance Imaging.

    Science.gov (United States)

    Harris, Wendy; Ren, Lei; Cai, Jing; Zhang, You; Chang, Zheng; Yin, Fang-Fang

    2016-06-01

    The purpose of this study was to develop a techique to generate on-board volumetric cine-magnetic resonance imaging (VC-MRI) using patient prior images, motion modeling, and on-board 2-dimensional cine MRI. One phase of a 4-dimensional MRI acquired during patient simulation is used as patient prior images. Three major respiratory deformation patterns of the patient are extracted from 4-dimensional MRI based on principal-component analysis. The on-board VC-MRI at any instant is considered as a deformation of the prior MRI. The deformation field is represented as a linear combination of the 3 major deformation patterns. The coefficients of the deformation patterns are solved by the data fidelity constraint using the acquired on-board single 2-dimensional cine MRI. The method was evaluated using both digital extended-cardiac torso (XCAT) simulation of lung cancer patients and MRI data from 4 real liver cancer patients. The accuracy of the estimated VC-MRI was quantitatively evaluated using volume-percent-difference (VPD), center-of-mass-shift (COMS), and target tracking errors. Effects of acquisition orientation, region-of-interest (ROI) selection, patient breathing pattern change, and noise on the estimation accuracy were also evaluated. Image subtraction of ground-truth with estimated on-board VC-MRI shows fewer differences than image subtraction of ground-truth with prior image. Agreement between normalized profiles in the estimated and ground-truth VC-MRI was achieved with less than 6% error for both XCAT and patient data. Among all XCAT scenarios, the VPD between ground-truth and estimated lesion volumes was, on average, 8.43 ± 1.52% and the COMS was, on average, 0.93 ± 0.58 mm across all time steps for estimation based on the ROI region in the sagittal cine images. Matching to ROI in the sagittal view achieved better accuracy when there was substantial breathing pattern change. The technique was robust against noise levels up to SNR = 20. For

  20. Volumetric particle image velocimetry with a single plenoptic camera

    Science.gov (United States)

    Fahringer, Timothy W.; Lynch, Kyle P.; Thurow, Brian S.

    2015-11-01

    A novel three-dimensional (3D), three-component (3C) particle image velocimetry (PIV) technique based on volume illumination and light field imaging with a single plenoptic camera is described. A plenoptic camera uses a densely packed microlens array mounted near a high resolution image sensor to sample the spatial and angular distribution of light collected by the camera. The multiplicative algebraic reconstruction technique (MART) computed tomography algorithm is used to reconstruct a volumetric intensity field from individual snapshots and a cross-correlation algorithm is used to estimate the velocity field from a pair of reconstructed particle volumes. This work provides an introduction to the basic concepts of light field imaging with a plenoptic camera and describes the unique implementation of MART in the context of plenoptic image data for 3D/3C PIV measurements. Simulations of a plenoptic camera using geometric optics are used to generate synthetic plenoptic particle images, which are subsequently used to estimate the quality of particle volume reconstructions at various particle number densities. 3D reconstructions using this method produce reconstructed particles that are elongated by a factor of approximately 4 along the optical axis of the camera. A simulated 3D Gaussian vortex is used to test the capability of single camera plenoptic PIV to produce a 3D/3C vector field, where it was found that lateral displacements could be measured to approximately 0.2 voxel accuracy in the lateral direction and 1 voxel in the depth direction over a 300× 200× 200 voxel volume. The feasibility of the technique is demonstrated experimentally using a home-built plenoptic camera based on a 16-megapixel interline CCD camera and a 289× 193 array of microlenses and a pulsed Nd:YAG laser. 3D/3C measurements were performed in the wake of a low Reynolds number circular cylinder and compared with measurements made using a conventional 2D/2C PIV system. Overall, single camera

  1. Transient refractory material dissolution by a volumetrically-heated melt

    Energy Technology Data Exchange (ETDEWEB)

    Seiler, Jean Marie, E-mail: jean-marie.seiler@cea.fr [CEA, DEN, DTN, 17 Rue des Martyrs, 38054 Grenoble Cedex 9 (France); Ratel, Gilles [CEA, DEN, DTN, 17 Rue des Martyrs, 38054 Grenoble Cedex 9 (France); Combeau, Hervé [Institut Jean Lamour, UMR 7198, Lorraine University, Ecole des Mines de Nancy, Parc de Saurupt, 54042 Nancy Cedex (France); Gaus-Liu, Xiaoyang; Kretzschmar, Frank; Miassoedov, Alexei [Karlsruhe Institut of Technology, Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen (Germany)

    2014-12-15

    Highlights: • We describe a test investigating ceramic dissolution by a molten non-eutectic melt. • The evolution of the interface temperature between melt and refractory is measured. • A theoretical model describing dissolution kinetics is proposed. • When dissolution stops, interface temperature is the liquidus temperature of the melt. - Abstract: The present work addresses the question of corium–ceramic interaction in a core catcher during a core-melt accident in a nuclear power plant. It provides an original insight into transient aspects concerning dissolution of refractory material by a volumetrically heated pool. An experiment with simulant material (LIVECERAM) is presented. Test results clearly show that dissolution of solid refractory material can occur in a non-eutectic melt at a temperature which is lower than the melting temperature of the refractory material. During the dissolution transient, the interface temperature rises above the liquidus temperature, corresponding to the instantaneous average composition of the melt pool. With constant power dissipation in the melt and external cooling of the core-catcher, a final steady-state situation is reached. Dissolution stops when the heat flux (delivered by the melt to the refractory) can be removed by conduction through the residual thickness of the ceramic, with T{sub interface} = T{sub liquidus} (calculated for the average composition of the final liquid pool). The final steady state corresponds to a uniform pool composition and uniform interface temperature distribution. Convection in the pool is governed by natural thermal convection and the heat flux distribution is therefore similar to what would be obtained for a single component pool. An interpretation of the experiment with two model-based approaches (0D and 1D) is presented. The mass transfer kinetics between the interface and the bulk is controlled by a diffusion sublayer within the boundary layer. During the dissolution transient

  2. Volumetric Forest Change Detection Through Vhr Satellite Imagery

    Science.gov (United States)

    Akca, Devrim; Stylianidis, Efstratios; Smagas, Konstantinos; Hofer, Martin; Poli, Daniela; Gruen, Armin; Sanchez Martin, Victor; Altan, Orhan; Walli, Andreas; Jimeno, Elisa; Garcia, Alejandro

    2016-06-01

    Quick and economical ways of detecting of planimetric and volumetric changes of forest areas are in high demand. A research platform, called FORSAT (A satellite processing platform for high resolution forest assessment), was developed for the extraction of 3D geometric information from VHR (very-high resolution) imagery from satellite optical sensors and automatic change detection. This 3D forest information solution was developed during a Eurostars project. FORSAT includes two main units. The first one is dedicated to the geometric and radiometric processing of satellite optical imagery and 2D/3D information extraction. This includes: image radiometric pre-processing, image and ground point measurement, improvement of geometric sensor orientation, quasiepipolar image generation for stereo measurements, digital surface model (DSM) extraction by using a precise and robust image matching approach specially designed for VHR satellite imagery, generation of orthoimages, and 3D measurements in single images using mono-plotting and in stereo images as well as triplets. FORSAT supports most of the VHR optically imagery commonly used for civil applications: IKONOS, OrbView - 3, SPOT - 5 HRS, SPOT - 5 HRG, QuickBird, GeoEye-1, WorldView-1/2, Pléiades 1A/1B, SPOT 6/7, and sensors of similar type to be expected in the future. The second unit of FORSAT is dedicated to 3D surface comparison for change detection. It allows users to import digital elevation models (DEMs), align them using an advanced 3D surface matching approach and calculate the 3D differences and volume changes between epochs. To this end our 3D surface matching method LS3D is being used. FORSAT is a single source and flexible forest information solution with a very competitive price/quality ratio, allowing expert and non-expert remote sensing users to monitor forests in three and four dimensions from VHR optical imagery for many forest information needs. The capacity and benefits of FORSAT have been tested in

  3. Improving plan quality for prostate volumetric-modulated arc therapy.

    Science.gov (United States)

    Wright, Katrina; Ferrari-Anderson, Janet; Barry, Tamara; Bernard, Anne; Brown, Elizabeth; Lehman, Margot; Pryor, David

    2017-08-04

    We critically evaluated the quality and consistency of volumetric-modulated arc therapy (VMAT) prostate planning at a single institution to quantify objective measures for plan quality and establish clear guidelines for plan evaluation and quality assurance. A retrospective analysis was conducted on 34 plans generated on the Pinnacle(3) version 9.4 and 9.8 treatment planning system to deliver 78 Gy in 39 fractions to the prostate only using VMAT. Data were collected on contoured structure volumes, overlaps and expansions, planning target volume (PTV) and organs at risk volumes and relationship, dose volume histogram, plan conformity, plan homogeneity, low-dose wash, and beam parameters. Standard descriptive statistics were used to describe the data. Despite a standardized planning protocol, we found variability was present in all steps of the planning process. Deviations from protocol contours by radiation oncologists and radiation therapists occurred in 12% and 50% of cases, respectively, and the number of optimization parameters ranged from 12 to 27 (median 17). This contributed to conflicts within the optimization process reflected by the mean composite objective value of 0.07 (range 0.01 to 0.44). Methods used to control low-intermediate dose wash were inconsistent. At the PTV rectum interface, the dose-gradient distance from the 74.1 Gy to 40 Gy isodose ranged from 0.6 cm to 2.0 cm (median 1.0 cm). Increasing collimator angle was associated with a decrease in monitor units and a single full 6 MV arc was sufficient for the majority of plans. A significant relationship was found between clinical target volume-rectum distance and rectal tolerances achieved. A linear relationship was determined between the PTV volume and volume of 40 Gy isodose. Objective values and composite objective values were useful in determining plan quality. Anatomic geometry and overlap of structures has a measurable impact on the plan quality achieved for prostate patients

  4. Volumetric humidity timely variation, at different depths, in soils of a toposequence of the Reconcavo Baiano - Brazil; Variacao da umidade volumetrica ao longo do tempo, em diferentes profundidades, em solos de uma topossequencia do Reconcavo Baiano

    Energy Technology Data Exchange (ETDEWEB)

    Ribeiro, Antonio Carlos; Costa, Liovando Marciano da [Vicosa Univ., MG (Brazil). Dept. de Solos; Paiva, Arlicelio de Queiroz [UESC, Ilheus, BA (Brazil). Dept. de Ciencias Agrarias e Ambientais. E-mail: aqpaiva@jacaranda.uescba.com.br; Souza, Luciano da Silva [Empresa Brasileira de Pesquisa Agropecuaria, Cruz das Almas, BA (Brazil). Centro Nacional de Pesquisa de Mandioca e Fruticultura. E-mail: lsouza@cnpmf.embrapa.br; Santana, Marlete Bastos [Bahia Univ., Cruz das Almas, BA (Brazil). Escola de Agronomia

    1997-07-01

    Aiming the time basis volumetric humidity evaluation, at different depths, the present work has been developed in a Reconcavo Baiano toposequence consisting of three different soils, in accordance with the distances from the toposequence begin. A neutron probe has been used for determination of the soil water contents. The relative counting of the neutron probe has been converted to gravimetric humidity by using regression equation for each type of soil.

  5. Semi-automated volumetric analysis of artificial lymph nodes in a phantom study.

    Science.gov (United States)

    Fabel, M; Biederer, J; Jochens, A; Bornemann, L; Soza, G; Heller, M; Bolte, H

    2011-12-01

    Quantification of tumour burden in oncology requires accurate and reproducible image evaluation. The current standard is one-dimensional measurement (e.g. RECIST) with inherent disadvantages. Volumetric analysis is discussed as an alternative for therapy monitoring of lung and liver metastases. The aim of this study was to investigate the accuracy of semi-automated volumetric analysis of artificial lymph node metastases in a phantom study. Fifty artificial lymph nodes were produced in a size range from 10 to 55mm; some of them enhanced using iodine contrast media. All nodules were placed in an artificial chest phantom (artiCHEST®) within different surrounding tissues. MDCT was performed using different collimations (1-5 mm) at varying reconstruction kernels (B20f, B40f, B60f). Volume and RECIST measurements were performed using Oncology Software (Siemens Healthcare, Forchheim, Germany) and were compared to reference volume and diameter by calculating absolute percentage errors. The software performance allowed a robust volumetric analysis in a phantom setting. Unsatisfying segmentation results were frequently found for native nodules within surrounding muscle. The absolute percentage error (APE) for volumetric analysis varied between 0.01 and 225%. No significant differences were seen between different reconstruction kernels. The most unsatisfactory segmentation results occurred in higher slice thickness (4 and 5 mm). Contrast enhanced lymph nodes showed better segmentation results by trend. The semi-automated 3D-volumetric analysis software tool allows a reliable and convenient segmentation of artificial lymph nodes in a phantom setting. Lymph nodes adjacent to tissue of similar density cause segmentation problems. For volumetric analysis of lymph node metastases in clinical routine a slice thickness of ≤3mm and a medium soft reconstruction kernel (e.g. B40f for Siemens scan systems) may be a suitable compromise for semi-automated volumetric analysis. Copyright

  6. Aumento del contenido de ácidos húmicos en un carbón de bajo rango a través de la oxidación con aire y con peróxido de hidrogeno o ácido nítrico Increase of the content of humic acids in a low rank coal by oxidation with air and with hydrogen peroxide or nitric acid

    Directory of Open Access Journals (Sweden)

    Ruben Anillo-Correa

    2013-01-01

    Full Text Available Low-rank coals are an important source of humic acids, which are important in retention processes of water and nutrients in plants. In this study coal samples of Montelibano, Colombia, were oxidized with air at different temperatures and subsequently with H2O2 and HNO3. The materials were characterized by FTIR, proximate and elemental analysis, and quantification of humic acids. The oxidation process led to an increased content of oxygenated groups and humic acids in the carbonaceous structure. The solid oxidized with air at 200 ºC for 12 h and re-oxidized with HNO3 for 12 h showed the highest percentage of humic acids (85.3%.

  7. Accuracy of fully automated, quantitative, volumetric measurement of the amount of fibroglandular breast tissue using MRI: correlation with anthropomorphic breast phantoms.

    Science.gov (United States)

    Wengert, Georg J; Pinker, Katja; Helbich, Thomas H; Vogl, Wolf-Dieter; Spijker, Sylvia M; Bickel, Hubert; Polanec, Stephan H; Baltzer, Pascal A

    2017-06-01

    To demonstrate the accuracy of fully automated, quantitative, volumetric measurement of the amount of fibroglandular breast tissue (FGT), using MRI, and to investigate the impact of different MRI sequences using anthropomorphic breast phantoms as the ground truth. In this study, 10 anthropomorphic breast phantoms that consisted of different known fractions of adipose and protein tissue, which closely resembled normal breast parenchyma, were developed. Anthropomorphic breast phantoms were imaged with a 1.5 T unit (Siemens, Avantofit) using an 18-channel breast coil. The sequence protocol consisted of an isotropic Dixon sequence (Di), an anisotropic Dixon sequence (Da), and T1 3D FLASH sequences with and without fat saturation (T1). Fully automated, quantitative, volumetric measurement of FGT for all anthropomorphic phantoms and sequences was performed and correlated with the amounts of fatty and protein components in the phantoms as the ground truth. Fully automated, quantitative, volumetric measurements of FGT with MRI for all sequences ranged from 5.86 to 61.05% (mean 33.36%). The isotropic Dixon sequence yielded the highest accuracy (median 0.51%-0.78%) and precision (median range 0.19%) compared with anisotropic Dixon (median 1.92%-2.09%; median range 0.55%) and T1 -weighted sequences (median 2.54%-2.46%; median range 0.82%). All sequences yielded good correlation with the FGT content of the anthropomorphic phantoms. The best correlation of FGT measurements was identified for Dixon sequences (Di, R(2)  = 0.999; Da, R(2)  = 0.998) compared with conventional T1 -weighted sequences (R(2)  = 0.971). MRI yields accurate, fully automated, quantitative, volumetric measurements of FGT, an increasingly important and sensitive imaging biomarker for breast cancer risk. Compared with conventional T1 sequences, Dixon-type sequences show the highest correlation and reproducibility for automated, quantitative, volumetric FGT measurements using anthropomorphic breast

  8. Time-lapse monitoring of soil water content using electromagnetic conductivity imaging

    Science.gov (United States)

    The volumetric soil water content (VWC) is fundamental to agriculture. Unfortunately, the universally accepted thermogravimetric method is labour intensive and time-consuming to use for field-scale monitoring. Electromagnetic (EM) induction instruments have proven to be useful in mapping the spatio-...

  9. Use of Water Content Reflectometers in Bioinfiltration/Bioretention to Measure Water Movement and Estimate Evapotranspiration

    Science.gov (United States)

    Most bioinfiltration/bioretention models assume runoff is evenly distributed across the surface area and after the engineered fill media is no longer saturated, the volumetric water content (VWC) is constant throughout the media profile and at field capacity. Four to nine water ...

  10. Semi-automated volumetric analysis of lymph node metastases during follow-up--initial results.

    Science.gov (United States)

    Fabel, Michael; Bolte, H; von Tengg-Kobligk, H; Bornemann, L; Dicken, V; Delorme, S; Kauczor, H-U; Heller, M; Biederer, J

    2011-04-01

    Quantification of tumour burden in oncology requires accurate and reproducible evaluation. The current standard is RECIST measurement with its inherent disadvantages. Volumetric analysis is an alternative for therapy monitoring. The aim of this study was to evaluate the feasibility of volumetric analysis of lymph node metastases using a software prototype in a follow-up setting. MSCT was performed in 50 patients covering the chest, abdomen and pelvis. A total of 174 suspicious lymph nodes were evaluated by two radiologists regarding short axis diameters and volumetric analysis using semi-automated software. Quality of segmentation, time, maximum diameter and volume were documented. Variability of the derived change rates was computed as the standard deviation of the difference of the obtained respective change rates. The software performance provides robust volumetric analysis. Quality of segmentation was rated acceptable to excellent in 76-79% by each reader. Mean time spent per lesion was 38 s. The variability of change in effective diameters was 10.6%; for change rates of RECIST maximum diameter variability was 27.5%. Semi-automated volumetric analysis allows fast and convenient segmentation of most lymph node metastases. Compared with RECIST the inter-observer-variability in baseline and follow-up is reduced. This should principally allow subtle changes to be subclassified within the RECIST stable range as minor response [-15% to +10%].

  11. MAIN CONTENTS

    Institute of Scientific and Technical Information of China (English)

    2011-01-01

    Discussion on the Modern Agriculture Management Mode and its Innovation in China Mode of agricultural management is organic unify between form of agriculture management and way of agriculture management. Changes of agricultural management form are the content of system innovation;Transformation of agricultural management way belongs to the category of technical progress. We found that, precision agriculture with the moderate scale by professional farmers is the dominant mode of agricultural management. Coexisting of multiple modes is the pattern and evolution trend of modern agriculture management mode. The precision agriculture based on household business of moderate scale mode, we needs of rural economd socialization of

  12. Content Analysis

    Directory of Open Access Journals (Sweden)

    George Bedinelli Rossi

    2014-09-01

    Full Text Available This study introduces the various definitions and types of content analysis. This type of analysis historically presents itself as a quantitative approach to data analysis and currently shows up as a qualitative approach. The most common types are the conceptual and relational analysis. The latter receives influences of linguistic, cognitive and mental models and it is subdivided in affective extraction, analysis of proximity and cognitive mapping. Regarding the importance of this type of analysis, we have quantitative and qualitative character and the latter approach can be used to identify hypotheses, theoretical constructs or even models that can be tested by multivariate statistical techniques or even by experiments. 

  13. Volumetric scale-up of smouldering remediation of contaminated materials.

    Science.gov (United States)

    Switzer, Christine; Pironi, Paolo; Gerhard, Jason I; Rein, Guillermo; Torero, Jose L

    2014-03-15

    Smouldering remediation is a process that has been introduced recently to address non-aqueous phase liquid (NAPL) contamination in soils and other porous media. Previous work demonstrated this process to be highly effective across a wide range of contaminants and soil conditions at the bench scale. In this work, a suite of 12 experiments explored the effectiveness of the process as operating scale was increased 1000-fold from the bench (0.003m(3)) to intermediate (0.3m(3)) and pilot field-scale (3m(3)) with coal tar and petrochemical NAPLs. As scale increased, remediation efficiency of 97-99.95% was maintained. Smouldering propagation velocities of 0.6-14×10(-5)m/s at Darcy air fluxes of 1.54-9.15cm/s were consistent with observations in previous bench studies, as was the dependence on air flux. The pilot field-scale experiments demonstrated the robustness of the process despite heterogeneities, localised operation, controllability through airflow supply, and the importance of a minimum air flux for self-sustainability. Experiments at the intermediate scale established a minimum-observed, not minimum-possible, initial concentration of 12,000mg/kg in mixed oil waste, providing support for the expectation that lower thresholds for self-sustaining smouldering decreased with increasing scale. Once the threshold was exceeded, basic process characteristics of average peak temperature, destructive efficiency, and treatment velocity were relatively independent of scale. Copyright © 2014 Elsevier B.V. All rights reserved.

  14. VOLUMETRIC MASS TRANSFER COEFFICIENT BETWEEN SLAG AND METAL IN COMBINED BLOWING CONVERTER

    Institute of Scientific and Technical Information of China (English)

    Z.H. Wu; Z.S. Zou; W. Wu

    2005-01-01

    The effects of operation parameters of combined blowing converter on the volumetric mass transfer coefficient between slag and steel are studied with a cold model with water simulating steel, oil simulating slag and benzoic acid as the transferred substance between water and oil. The results show that, with lance level of 2.Im and the top blowing rate of 25000Nm3/h, the volumetric mass transfer coefficient changes most significantly when the bottom blowing rate ranges from 384 to 540Nm3/h. The volumetric mass transfer coefficient reaches its maximum when the lance level is 2. lm, the top blowing rates is 30000Nm3/h, and the bottom blowing rate is 384Nrr3/h with tuyeres located symmetrically at 0.66D of the converter bottom.

  15. Control and design of volumetric composition in pultruded hybrid fibre composites

    DEFF Research Database (Denmark)

    Madsen, Bo; Hashemi, Fariborz; Tahir, Paridah

    2016-01-01

    Hybrid composites consist of two of more fibre phases in a common matrix phase. This is a challenge for the control and design of the volumetric composition and microstructural uniformity of such composites. In the present study, a model is presented for the prediction of the complete volumetric...... composition (i.e. volume fractions of fibres, matrix and porosity) in hybrid fibre composites. The model is based on a constant local fibre volume fraction criterion. Good agreement is found between model predictions and experimental data of pultruded hybrid kenaf/glass fibre composites with variable hybrid...... fibre weight mixing ratios. To demonstrate the suitability of the model, simulations are performed for four different cases of volumetric composition in hybrid kenaf/glass composites....

  16. NDE Technology Development Program for Non-Visual Volumetric Inspection Technology; Sensor Effectiveness Testing Report

    Energy Technology Data Exchange (ETDEWEB)

    Moran, Traci L.; Larche, Michael R.; Denslow, Kayte M.; Glass, Samuel W.

    2017-08-31

    The Pacific Northwest National Laboratory (PNNL) located in Richland, Washington, hosted and administered Sensor Effectiveness Testing that allowed four different participants to demonstrate the NDE volumetric inspection technologies that were previously demonstrated during the Technology Screening session. This document provides a Sensor Effectiveness Testing report for the final part of Phase I of a three-phase NDE Technology Development Program designed to identify and mature a system or set of non-visual volumetric NDE technologies for Hanford DST primary liner bottom inspection. Phase I of the program will baseline the performance of current or emerging non-visual volumetric NDE technologies for their ability to detect and characterize primary liner bottom flaws, and identify candidate technologies for adaptation and maturation for Phase II of the program.

  17. Ultrahigh volumetric capacitance and cyclic stability of fluorine and nitrogen co-doped carbon microspheres

    Science.gov (United States)

    Zhou, Junshuang; Lian, Jie; Hou, Li; Zhang, Junchuan; Gou, Huiyang; Xia, Meirong; Zhao, Yufeng; Strobel, Timothy A.; Tao, Lu; Gao, Faming

    2015-09-01

    Highly porous nanostructures with large surface areas are typically employed for electrical double-layer capacitors to improve gravimetric energy storage capacity; however, high surface area carbon-based electrodes result in poor volumetric capacitance because of the low packing density of porous materials. Here, we demonstrate ultrahigh volumetric capacitance of 521 F cm-3 in aqueous electrolytes for non-porous carbon microsphere electrodes co-doped with fluorine and nitrogen synthesized by low-temperature solvothermal route, rivaling expensive RuO2 or MnO2 pseudo-capacitors. The new electrodes also exhibit excellent cyclic stability without capacitance loss after 10,000 cycles in both acidic and basic electrolytes at a high charge current of 5 A g-1. This work provides a new approach for designing high-performance electrodes with exceptional volumetric capacitance with high mass loadings and charge rates for long-lived electrochemical energy storage systems.

  18. Combination volumetric and gravimetric sorption instrument for high accuracy measurements of methane adsorption

    Science.gov (United States)

    Burress, Jacob; Bethea, Donald; Troub, Brandon

    2017-05-01

    The accurate measurement of adsorbed gas up to high pressures (˜100 bars) is critical for the development of new materials for adsorbed gas storage. The typical Sievert-type volumetric method introduces accumulating errors that can become large at maximum pressures. Alternatively, gravimetric methods employing microbalances require careful buoyancy corrections. In this paper, we present a combination gravimetric and volumetric system for methane sorption measurements on samples between ˜0.5 and 1 g. The gravimetric method described requires no buoyancy corrections. The tandem use of the gravimetric method allows for a check on the highest uncertainty volumetric measurements. The sources and proper calculation of uncertainties are discussed. Results from methane measurements on activated carbon MSC-30 and metal-organic framework HKUST-1 are compared across methods and within the literature.

  19. Single step full volumetric reconstruction optical coherence tomography utilizing compressive sensing

    Science.gov (United States)

    Chen, Luoyang; Liu, Jiansheng; cheng, Jiangtao; Liu, Haitao; Zhou, Hongwen

    2017-03-01

    3D optical coherence tomography imaging (OCT) combined with compressive sensing (CS) has been proved to be an attractive and effective tool in a variety of fields, such as medicine and biology. To achieve high quality imaging while using as less CS sampling rate as possible is the goal of this approach. Here we present an innovative single step fully 3D CS-OCT volumetric image recovery method, in which 3D OCT volumetric image of the object is compressively sampled via our proposed CS coding strategies in all three dimensions while its sparsity is simultaneously taken into consideration in every direction. The object can be directly recovered as the whole volume reconstruction via our advanced full 3D CS reconstruction algorithm. The numerical simulations of a human retina OCT volumetric image reconstruction by our method demonstrate a PSNR of as high as 38dB at a sampling rate of less than 10%.

  20. Seeding optimization for instantaneous volumetric velocimetry. Application to a jet in crossflow

    CERN Document Server

    Cambonie, Tristan

    2014-01-01

    Every volumetric velocimetry measurements based on tracer (particles, bubbles, etc.) detection can be strongly influenced by the optical screening phenomenon. It has to be taken into account when the the statistical properties associated to the performances of the particle detection and tracking algorithms are significantly affected. It leads to a maximum concentration of particles in the images thus limiting the final spatial resolution of the instantaneous three-dimensional three-components (3D3C) velocity fields. A volumetric velocimetry system based on Defocused Digital Particle Image Velocimetry is used to show that above a critical visual concentration of particles in the images, the concentration and accuracy of the final instantaneous raw velocity vector field drop. The critical concentration depends on physical parameters as well as on the processing algorithms. Three distinct regimes are identified. In the first regime, the concentration is well adapted to volumetric velocimetry, the largest concent...

  1. Volumetric Concentration Maximum of Cohesive Sediment in Waters: A Numerical Study

    Directory of Open Access Journals (Sweden)

    Jisun Byun

    2014-12-01

    Full Text Available Cohesive sediment has different characteristics compared to non-cohesive sediment. The density and size of a cohesive sediment aggregate (a so-called, floc continuously changes through the flocculation process. The variation of floc size and density can cause a change of volumetric concentration under the condition of constant mass concentration. This study investigates how the volumetric concentration is affected by different conditions such as flow velocity, water depth, and sediment suspension. A previously verified, one-dimensional vertical numerical model is utilized here. The flocculation process is also considered by floc in the growth type flocculation model. Idealized conditions are assumed in this study for the numerical experiments. The simulation results show that the volumetric concentration profile of cohesive sediment is different from the Rouse profile. The volumetric concentration decreases near the bed showing the elevated maximum in the cases of both current and oscillatory flow. The density and size of floc show the minimum and the maximum values near the elevation of volumetric concentration maximum, respectively. This study also shows that the flow velocity and the critical shear stress have significant effects on the elevated maximum of volumetric concentration. As mechanisms of the elevated maximum, the strong turbulence intensity and increased mass concentration are considered because they cause the enhanced flocculation process. This study uses numerical experiments. To the best of our knowledge, no laboratory or field experiments on the elevated maximum have been carried out until now. It is of great necessity to conduct well-controlled laboratory experiments in the near future.

  2. Centrifugal Blower for Personal Air Ventilation System (PAVS) - Phase 1

    Science.gov (United States)

    2015-02-01

    functionality. 15. SUBJECT TERMS COOLING SBIR REPORTS AXIAL FLOW FANS OFF THE SHELF EQUIPMENT BLOWERS LIGHTWEIGHT CENTRIFUGAL FORCE...HEAT STRESS (PHYSIOLOGY) AIR FLOW VENTILATION PORTABLE EQUIPMENT PERSONAL COOLING SYSTEMS EFFICIENCY EVAPORATION INTEGRATED SYSTEMS PROTOTYPES...gH Vn ad s ad s 4 1 4 3     is angular speed (2rpm) V is volumetric flow rate Had is the fan pumping head (in meters) g is the

  3. Using pressure and volumetric approaches to estimate CO2 storage capacity in deep saline aquifers

    OpenAIRE

    Thibeau, S.; Bachu, S.; Birkholzer, J.; Holloway, S; Neele, F.P.; Zou, Q

    2014-01-01

    Various approaches are used to evaluate the capacity of saline aquifers to store CO2, resulting in a wide range of capacity estimates for a given aquifer. The two approaches most used are the volumetric “open aquifer” and “closed aquifer” approaches. We present four full-scale aquifer cases, where CO2 storage capacity is evaluated both volumetrically (with “open” and/or “closed” approaches) and through flow modeling. These examples show that the “open aquifer” CO2 storage capacity estimation ...

  4. Effects of volumetric allocation on heave response of semisubmersible in deep sea

    Institute of Scientific and Technical Information of China (English)

    2009-01-01

    The configuration of semisubmersibles consisting of pontoons and columns and their corresponding heave motion response in incident progressive waves are examined. The purpose of the present study is to provide a theoretical approach to estimating the effects of volumetric allocation on natural period and response amplitude operator (RAO) in heave motion. We conclude that the amplitude of heave motion response can be considerably suppressed by appropriately adjusting volumetric allocation so that the natural heave period keeps away from the range of wave energy. The theoretical formulae are found in good agreement with the corresponding computational results by WAMIT.

  5. Volumetric Diffuse Optical Tomography for Small Animals Using a CCD-Camera-Based Imaging System

    Directory of Open Access Journals (Sweden)

    Zi-Jing Lin

    2012-01-01

    Full Text Available We report the feasibility of three-dimensional (3D volumetric diffuse optical tomography for small animal imaging by using a CCD-camera-based imaging system with a newly developed depth compensation algorithm (DCA. Our computer simulations and laboratory phantom studies have demonstrated that the combination of a CCD camera and DCA can significantly improve the accuracy in depth localization and lead to reconstruction of 3D volumetric images. This approach may present great interests for noninvasive 3D localization of an anomaly hidden in tissue, such as a tumor or a stroke lesion, for preclinical small animal models.

  6. DIRECT VOXEL-PROJECTION FOR VOLUMETRIC DATA RENDERING IN MEDICAL IMAGERY

    Institute of Scientific and Technical Information of China (English)

    吕忆松; 陈亚珠; 郭玉红

    2002-01-01

    The volumetric rendering of 3-D medical image data is very effective method for communication about radiological studies to clinicians. Algorithms that produce images with artifacts and inaccuracies are not clinically useful. This paper proposed a direct voxel-projection algorithm to implement volumetric data rendering. Using this algorithm, arbitrary volume rotation, transparent and cutaway views are generated satisfactorily. Compared with the existing raytracing methods, it improves the projection image quality greatly. Some experimental results about real medical CT image data demonstrate the advantages and fidelity of the proposed algorithm.

  7. Fairy Lights in Femtoseconds: Aerial and Volumetric Graphics Rendered by Focused Femtosecond Laser Combined with Computational Holographic Fields

    CERN Document Server

    Ochiai, Yoichi; Hoshi, Takayuki; Rekimoto, Jun; Hasegawa, Satoshi; Hayasaki, Yoshio

    2015-01-01

    We present a method of rendering aerial and volumetric graphics using femtosecond lasers. A high-intensity laser excites a physical matter to emit light at an arbitrary 3D position. Popular applications can then be explored especially since plasma induced by a femtosecond laser is safer than that generated by a nanosecond laser. There are two methods of rendering graphics with a femtosecond laser in air: Producing holograms using spatial light modulation technology, and scanning of a laser beam by a galvano mirror. The holograms and workspace of the system proposed here occupy a volume of up to 1 cm^3; however, this size is scalable depending on the optical devices and their setup. This paper provides details of the principles, system setup, and experimental evaluation, and discussions on scalability, design space, and applications of this system. We tested two laser sources: an adjustable (30-100 fs) laser which projects up to 1,000 pulses per second at energy up to 7 mJ per pulse, and a 269-fs laser which p...

  8. Evaluation of air lime and clayish earth mortars for earthen wall renders

    OpenAIRE

    Faria, Paulina; Silva, Vitor; Jamú, Naila; Dias, Inês; Gomes, M. Idália

    2013-01-01

    CIAV2013 – International Conference on Vernacular Architecture, 7º ATP, VerSus, 16-20 october 2013 An experimental rammed earth wall was traditionally made with local earth and characterized in terms of superficial hardness, compactness, thermal conductivity and water absorption, in exterior environmental conditions. Two mortars were made with an air lime and a mixture of three washed graduated siliceous sands, with volumetric proportions of 1:2 and 1:3 (air lime:sand). A clayish earth was...

  9. RADON CONCENTRATION IN THE AIR OF NEWLY BUILT AND OPERATING BUILDINGS IN THE ROSTOV REGION

    Directory of Open Access Journals (Sweden)

    M. Yu Soloviev

    2010-01-01

    Full Text Available The article presents issues of radon accumulation in the air of dwellings and public buildings in the Rostov region. It is shown that radon concentration in the air of commissioned buildings does not depend on the season when the investigation was carried out, while equivalent equilibrium volumetric activity of radon in the operating buildings is approximately twice higher during the cold period, then during the hot period of a year.

  10. Correlation Between Liver Volumetric Computed Tomography Results and Measured Liver Weight: A Tool for Preoperative Planning of Liver Transplant

    NARCIS (Netherlands)

    Sonnemans, L.J.; Hol, J.C.; Monshouwer, R.; Prokop, M.; Klein, W.M.

    2016-01-01

    OBJECTIVES: Before liver transplant, it is necessary to know the size of the organ in advance of the procedure. We studied the correlation between liver volumetric computed tomography results and liver weight. MATERIALS AND METHODS: Postmortem volumetric computed tomography was conducted on cadavers

  11. Two-dimensional and volumetric airway changes after bimaxillary surgery for class III malocclusion.

    Science.gov (United States)

    Vaezi, Toraj; Zarch, Seyed Hossein Hosseini; Eshghpour, Majid; Kermani, Hamed

    2017-04-01

    Any change in maxilla and mandible position can alter the upper airway, and any decrease in the upper airway can cause sleep disorders. Thus, it is necessary to assess airway changes after repositioning of the maxilla and mandible during orthognathic surgery. The purpose of this study was to evaluate linear and volumetric changes in the upper airway after bimaxillary surgery to correct class III malocclusion via cone-beam computed tomography (CBCT) and to identify correlations between linear and volumetric changes. This was a prospective cohort study. CBCTs from 10 class III patients were evaluated before surgery and three months after. The Wilcoxon one-sample test was used to evaluate the differences in measurements before and after surgery. Spearman's rank correlation coefficient was used to test the correlation between linear and volumetric changes. The results show that the nasopharyngeal space increased significantly, and that this increase correlated with degree of maxillary advancement. No significant changes were found in volumes before and after surgery. A correlation was found between linear and volumetric oropharyngeal changes. Bimaxillary surgical correction of class III malocclusion did not cause statistically significant changes in the posterior airway space.

  12. MATHEMATICAL MODEL FOR DETERMINATION OF VOLUMETRIC OUTPUT OF LUMBER FROM LOGS, CONTAINING SEVERAL QUALITY AREAS

    Directory of Open Access Journals (Sweden)

    Mikryukova E. V.

    2014-12-01

    Full Text Available In the article we present a method of cutting logs, containing several quality areas. For this method, a mathematical model was developed to determine the volumetric output of lumber, which allows to determine the geometric dimensions of the lumber cut from the different quality areas separated concentric circles, depending on size and quality characteristics of logs

  13. Trapping volumetric measurement by multidetector CT in chronic obstructive pulmonary disease: Effect of CT threshold

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Xiaohua; Yuan, Huishu [Department of Radiology, Peking University Third Hospital, Beijing 100191 (China); Duan, Jianghui [Medical School, Peking University, Beijing 100191 (China); Du, Yipeng; Shen, Ning; He, Bei [Department of Respiration Internal Medicine, Peking University Third Hospital, Beijing 100191 (China)

    2013-08-15

    Purpose: The purpose of this study was to evaluate the effect of various computed tomography (CT) thresholds on trapping volumetric measurements by multidetector CT in chronic obstructive pulmonary disease (COPD).Methods: Twenty-three COPD patients were scanned with a 64-slice CT scanner in both the inspiratory and expiratory phase. CT thresholds of −950 Hu in inspiration and −950 to −890 Hu in expiration were used, after which trapping volumetric measurements were made using computer software. Trapping volume percentage (Vtrap%) under the different CT thresholds in the expiratory phase and below −950 Hu in the inspiratory phase was compared and correlated with lung function.Results: Mean Vtrap% was similar under −930 Hu in the expiratory phase and below −950 Hu in the inspiratory phase, being 13.18 ± 9.66 and 13.95 ± 6.72 (both lungs), respectively; this difference was not significant (P= 0.240). Vtrap% under −950 Hu in the inspiratory phase and below the −950 to −890 Hu threshold in the expiratory phase was moderately negatively correlated with the ratio of forced expiratory volume in one second to forced vital capacity and the measured value of forced expiratory volume in one second as a percentage of the predicted value.Conclusions: Trapping volumetric measurement with multidetector CT is a promising method for the quantification of COPD. It is important to know the effect of various CT thresholds on trapping volumetric measurements.

  14. Transplantation and Perfusion of Microvascular Fragments in a Rodent Model of Volumetric Muscle Loss Injury

    Science.gov (United States)

    2014-07-01

    options are available for the treatment of volumetric muscle loss (VML). An important consideration that needs to be addressed for the development ...fibroblasts that underwent vascular and myogenic development in vitro resulted in substantial tissue perfusion when implanted in an abdominal defect...Greene AS (2000) Development of an implantable muscle stimulator: measurement of stimulated angiogenesis and poststimulus vessel regression

  15. Optical Addressing of Multi-Colour Photochromic Material Mixture for Volumetric Display

    Science.gov (United States)

    Hirayama, Ryuji; Shiraki, Atsushi; Naruse, Makoto; Nakamura, Shinichiro; Nakayama, Hirotaka; Kakue, Takashi; Shimobaba, Tomoyoshi; Ito, Tomoyoshi

    2016-08-01

    This is the first study to demonstrate that colour transformations in the volume of a photochromic material (PM) are induced at the intersections of two control light channels, one controlling PM colouration and the other controlling decolouration. Thus, PM colouration is induced by position selectivity, and therefore, a dynamic volumetric display may be realised using these two control lights. Moreover, a mixture of multiple PM types with different absorption properties exhibits different colours depending on the control light spectrum. Particularly, the spectrum management of the control light allows colour-selective colouration besides position selectivity. Therefore, a PM-based, full-colour volumetric display is realised. We experimentally construct a mixture of two PM types and validate the operating principles of such a volumetric display system. Our system is constructed simply by mixing multiple PM types; therefore, the display hardware structure is extremely simple, and the minimum size of a volume element can be as small as the size of a molecule. Volumetric displays can provide natural three-dimensional (3D) perception; therefore, the potential uses of our system include high-definition 3D visualisation for medical applications, architectural design, human–computer interactions, advertising, and entertainment.

  16. VOLUMETRIC METHOD FOR EVALUATION OF BEACHES VARIABILITY BASED ON GIS-TOOLS

    Directory of Open Access Journals (Sweden)

    V. V. Dolotov

    2015-01-01

    Full Text Available In frame of cadastral beach evaluation the volumetric method of natural variability index is proposed. It base on spatial calculations with Cut-Fill method and volume accounting ofboththe common beach contour and specific areas for the each time.

  17. Using pressure and volumetric approaches to estimate CO2 storage capacity in deep saline aquifers

    NARCIS (Netherlands)

    Thibeau, S.; Bachu, S.; Birkholzer, J.; Holloway, S.; Neele, F.P.; Zou, Q.

    2014-01-01

    Various approaches are used to evaluate the capacity of saline aquifers to store CO2, resulting in a wide range of capacity estimates for a given aquifer. The two approaches most used are the volumetric “open aquifer” and “closed aquifer” approaches. We present four full-scale aquifer cases, where C

  18. Exploration of volumetric cerebral changes, with de micro-MRi, due to psychomotor exercise in mice

    OpenAIRE

    Moës, Florian; Plenevaux, Alain; Becker, Guillaume; Tirelli, Ezio; Lespine, Louis-Ferdinand

    2015-01-01

    It's well know that exercise is good for health .In addition exercise has postive effects on cognition ,neurodegenerative disease and on mood. Some studies show that exercise has effect on brain so the aim of this study is to see if there are volumetric changes due to exercise or not.

  19. Effect of compression paddle tilt correction on volumetric breast density estimation.

    Science.gov (United States)

    Kallenberg, Michiel G J; van Gils, Carla H; Lokate, Mariëtte; den Heeten, Gerard J; Karssemeijer, Nico

    2012-08-21

    For the acquisition of a mammogram, a breast is compressed between a compression paddle and a support table. When compression is applied with a flexible compression paddle, the upper plate may be tilted, which results in variation in breast thickness from the chest wall to the breast margin. Paddle tilt has been recognized as a major problem in volumetric breast density estimation methods. In previous work, we developed a fully automatic method to correct the image for the effect of compression paddle tilt. In this study, we investigated in three experiments the effect of paddle tilt and its correction on volumetric breast density estimation. Results showed that paddle tilt considerably affected accuracy of volumetric breast density estimation, but that effect could be reduced by tilt correction. By applying tilt correction, a significant increase in correspondence between mammographic density estimates and measurements on MRI was established. We argue that in volumetric breast density estimation, tilt correction is both feasible and essential when mammographic images are acquired with a flexible compression paddle.

  20. Follow-up after gamma knife radiosurgery for vestibular schwannomas: volumetric and axial control rates

    NARCIS (Netherlands)

    Timmer, F.C.A.; Hanssens, P.E.; Haren, A.E. van; Overbeeke, J.J. van; Mulder, J.J.S.; Cremers, C.W.R.J.; Graamans, K.

    2011-01-01

    OBJECTIVES/HYPOTHESIS: A prospective long-term follow-up study was conducted to evaluate the results of gamma knife radiosurgery (GKRS) for vestibular schwannoma (VS) patients. Both axial and volumetric measurements are used to determine tumor size during follow-up. STUDY DESIGN: Individual prospect

  1. Empirical correlation of volumetric mass transfer coefficient for a rectangular internal-loop airlift bioreactor

    Science.gov (United States)

    An empirical correlation of volumetric mass transfer coefficient was developed for a pilot scale internal-loop rectangular airlift bioreactor that was designed for biotechnology. The empirical correlation combines classic turbulence theory, Kolmogorov’s isotropic turbulence theory with Higbie’s pen...

  2. Accelerated partial breast irradiation (APBI): are breath-hold and volumetric radiation therapy techniques useful?

    NARCIS (Netherlands)

    Essers, M.; Osman, S.O.; Hol, S.; Donkers, T.; Poortmans, P.M.P.

    2014-01-01

    BACKGROUND: In a selective group of patients accelerated partial breast irradiation (APBI) might be applied after conservative breast surgery to reduce the amount of irradiated healthy tissue. The role of volumetric modulated arc therapy (VMAT) and voluntary moderately deep inspiration breath-hold (

  3. The NCS code of practice for the quality assurance and control for volumetric modulated arc therapy

    NARCIS (Netherlands)

    Mans, Anton; Schuring, Danny; Arends, Mark P.; Vugts, Cornelia A. J. M.; Wolthaus, Jochem W. H.; Lotz, Heidi T.; Admiraal, Marjan; Louwe, Rob J. W.; Ollers, Michel C.; van de Kamer, Jeroen B.

    2016-01-01

    In 2010, the NCS (Netherlands Commission on Radiation Dosimetry) installed a subcommittee to develop guidelines for quality assurance and control for volumetric modulated arc therapy (VMAT) treatments. The report (published in 2015) has been written by Dutch medical physicists and has therefore, ine

  4. Development, Construction, and Operation of a Multisample Volumetric Apparatus for the Study of Gas Adsorption Equilibrium

    Science.gov (United States)

    Ribeiro, Rui P. P. L.; Silva, Ricardo J. S.; Esteves, Isabel A. A. C.; Mota, Jose´ P. B.

    2015-01-01

    The construction of a simple volumetric adsorption apparatus is highlighted. The setup is inexpensive and provides a clear demonstration of gas phase adsorption concepts. The topic is suitable for undergraduate chemistry and chemical engineering students. Moreover, this unit can also provide quantitative data that can be used by young researchers…

  5. Real-time volumetric deformable models for surgery simulation using finite elements and condensation

    DEFF Research Database (Denmark)

    Bro-Nielsen, Morten; Cotin, S.

    1996-01-01

    This paper discusses the application of SD solid volumetric Finite Element models to surgery simulation. In particular it introduces three new ideas for solving the problem of achieving real-time performance for these models. The simulation system we have developed is described and we demonstrate...

  6. Automated volumetric grid generation for finite element modeling of human hand joints

    Energy Technology Data Exchange (ETDEWEB)

    Hollerbach, K.; Underhill, K. [Lawrence Livermore National Lab., CA (United States); Rainsberger, R. [XYZ Scientific Applications, Inc., Livermore, CA (United States)

    1995-02-01

    We are developing techniques for finite element analysis of human joints. These techniques need to provide high quality results rapidly in order to be useful to a physician. The research presented here increases model quality and decreases user input time by automating the volumetric mesh generation step.

  7. Using pressure and volumetric approaches to estimate CO2 storage capacity in deep saline aquifers

    NARCIS (Netherlands)

    Thibeau, S.; Bachu, S.; Birkholzer, J.; Holloway, S.; Neele, F.P.; Zou, Q.

    2014-01-01

    Various approaches are used to evaluate the capacity of saline aquifers to store CO2, resulting in a wide range of capacity estimates for a given aquifer. The two approaches most used are the volumetric “open aquifer” and “closed aquifer” approaches. We present four full-scale aquifer cases, where

  8. Follow-up after gamma knife radiosurgery for vestibular schwannomas: volumetric and axial control rates

    NARCIS (Netherlands)

    Timmer, F.C.A.; Hanssens, P.E.; Haren, A.E. van; Overbeeke, J.J. van; Mulder, J.J.S.; Cremers, C.W.R.J.; Graamans, K.

    2011-01-01

    OBJECTIVES/HYPOTHESIS: A prospective long-term follow-up study was conducted to evaluate the results of gamma knife radiosurgery (GKRS) for vestibular schwannoma (VS) patients. Both axial and volumetric measurements are used to determine tumor size during follow-up. STUDY DESIGN: Individual

  9. Species-specific contribution of volumetric growth and tissue convergence to posterior body elongation in vertebrates.

    Science.gov (United States)

    Steventon, Ben; Duarte, Fernando; Lagadec, Ronan; Mazan, Sylvie; Nicolas, Jean-François; Hirsinger, Estelle

    2016-05-15

    Posterior body elongation is a widespread mechanism propelling the generation of the metazoan body plan. The posterior growth model predicts that a posterior growth zone generates sufficient tissue volume to elongate the posterior body. However, there are energy supply-related differences between vertebrates in the degree to which growth occurs concomitantly with embryogenesis. By applying a multi-scalar morphometric analysis in zebrafish embryos, we show that posterior body elongation is generated by an influx of cells from lateral regions, by convergence-extension of cells as they exit the tailbud, and finally by a late volumetric growth in the spinal cord and notochord. Importantly, the unsegmented region does not generate additional tissue volume. Fibroblast growth factor inhibition blocks tissue convergence rather than volumetric growth, showing that a conserved molecular mechanism can control convergent morphogenesis through different cell behaviours. Finally, via a comparative morphometric analysis in lamprey, dogfish, zebrafish and mouse, we propose that elongation via posterior volumetric growth is linked to increased energy supply and is associated with an overall increase in volumetric growth and elongation. © 2016. Published by The Company of Biologists Ltd.

  10. Cerebrospinal fluid volumetric MRI mapping as a simple measurement for evaluating brain atrophy

    NARCIS (Netherlands)

    De Vis, J B; Zwanenburg, J J|info:eu-repo/dai/nl/290473683; van der Kleij, L A; Spijkerman, J M; Biessels, G J|info:eu-repo/dai/nl/165576367; Hendrikse, J|info:eu-repo/dai/nl/266590268; Petersen, E T

    2016-01-01

    OBJECTIVES: To assess whether volumetric cerebrospinal fluid (CSF) MRI can be used as a surrogate for brain atrophy assessment and to evaluate how the T2 of the CSF relates to brain atrophy. METHODS: Twenty-eight subjects [mean age 64 (sd 2) years] were included; T1-weighted and CSF MRI were perform

  11. Ni foam cathode enables high volumetric H2 production in a microbial electrolysis cell

    NARCIS (Netherlands)

    Jeremiasse, A.W.; Hamelers, H.V.M.; Saakes, M.; Buisman, C.J.N.

    2010-01-01

    Valuable, “green” H2 can be produced with a microbial electrolysis cell (MEC). To achieve a high volumetric production rate of high purity H2, a continuous flow MEC with an anion exchange membrane, a flow through bioanode and a flow through Ni foam cathode was constructed. At an electrical energy in

  12. Semiautomated volumetric response evaluation as an imaging biomarker in superior sulcus tumors

    Energy Technology Data Exchange (ETDEWEB)

    Vos, C.G.; Paul, M.A. [VU University Medical Center, Departments of Surgery, Amsterdam (Netherlands); Dahele, M.; Soernsen de Koste, J.R. van; Senan, S. [VU University Medical Center, Departments of Radiation Oncology, Amsterdam (Netherlands); Bahce, I.; Smit, E.F. [VU University Medical Center, Departments of Pulmonary Diseases, Amsterdam (Netherlands); Thunnissen, E. [VU University Medical Center, Departments of Pathology, Amsterdam (Netherlands); Hartemink, K.J. [VU University Medical Center, Departments of Surgery, Amsterdam (Netherlands); Netherlands Cancer Institute - Antoni van Leeuwenhoek Hospital (NKI-AVL), Department of Surgery, Amsterdam (Netherlands)

    2014-02-15

    Volumetric response to therapy has been suggested as a biomarker for patient-centered outcomes. The primary aim of this pilot study was to investigate whether the volumetric response to induction chemoradiotherapy was associated with pathological complete response (pCR) or survival in patients with superior sulcus tumors managed with trimodality therapy. The secondary aim was to evaluate a semiautomated method for serial volume assessment. In this retrospective study, treatment outcomes were obtained from a departmental database. The tumor was delineated on the computed tomography (CT) scan used for radiotherapy planning, which was typically performed during the first cycle of chemotherapy. These contours were transferred to the post-chemoradiotherapy diagnostic CT scan using deformable image registration (DIR) with/without manual editing. CT scans from 30 eligible patients were analyzed. Median follow-up was 51 months. Neither absolute nor relative reduction in tumor volume following chemoradiotherapy correlated with pCR or 2-year survival. The tumor volumes determined by DIR alone and DIR + manual editing correlated to a high degree (R{sup 2} = 0.99, P < 0.01). Volumetric response to induction chemoradiotherapy was not correlated with pCR or survival in patients with superior sulcus tumors managed with trimodality therapy. DIR-based contour propagation merits further evaluation as a tool for serial volumetric assessment. (orig.)

  13. Toddlers with autism; metabolic, radiologic, and volumetric aspects of brain development

    NARCIS (Netherlands)

    Zeegers, M.

    2006-01-01

    The overall aim of this thesis is to study MR spectroscopic, radiologic, and volumetric brain correlates in very young children with severe developmental disorders; ASD, mental retardation, and language disorder. We wished to examine brain – behaviour relationships in children with ASD at a very you

  14. A hand-held row-column addressed CMUT probe with integrated electronics for volumetric imaging

    DEFF Research Database (Denmark)

    Engholm, Mathias; Christiansen, Thomas Lehrmann; Beers, Christopher;

    2015-01-01

    A 3 MHz, λ / 2-pitch 62+62 channel row-column addressed 2-D CMUT array designed to be mounted in a probe handle and connected to a commercial BK Medical scanner for real-time volumetric imaging is presented. It is mounted and wire-bonded on a flexible PCB, which is connected to two rigid PCBs wit...

  15. Real-time volumetric deformable models for surgery simulation using finite elements and condensation

    DEFF Research Database (Denmark)

    Bro-Nielsen, Morten; Cotin, S.

    1996-01-01

    This paper discusses the application of SD solid volumetric Finite Element models to surgery simulation. In particular it introduces three new ideas for solving the problem of achieving real-time performance for these models. The simulation system we have developed is described and we demonstrate...

  16. Mathematical Model Defining Volumetric Losses of Hydraulic Oil Compression in a Variable Capacity Displacement Pump

    Directory of Open Access Journals (Sweden)

    Paszota Zygmunt

    2015-01-01

    Full Text Available The objective of the work is to develop the capability of evaluating the volumetric losses of hydraulic oil compression in the working chambers of high pressure variable capacity displacement pump. Volumetric losses of oil compression must be determined as functions of the same parameters, which the volumetric losses due to leakage, resulting from the quality of design solution of the pump, are evaluated as dependent on and also as function of the oil aeration coefficient Ɛ. A mathematical model has been developed describing the hydraulic oil compressibility coefficient klc|Δppi;Ɛ;v as a relation to the ratio ΔpPi/pn of indicated increase ΔpPi of pressure in the working chambers and the nominal pressure pn, to the pump capacity coefficient bP, to the oil aeration coefficient  and to the ratio v/vnof oil viscosity v and reference viscosity vn. A mathematical model is presented of volumetric losses qpvc|ΔpPi;bp;;vof hydraulic oil compression in the pump working chambers in the form allowing to use it in the model of power of losses and energy efficiency

  17. Progress in two-dimensional arrays for real-time volumetric imaging.

    Science.gov (United States)

    Light, E D; Davidsen, R E; Fiering, J O; Hruschka, T A; Smith, S W

    1998-01-01

    The design, fabrication, and evaluation of two dimensional array transducers for real-time volumetric imaging are described. The transducers we have previously described operated at frequencies below 3 MHz and were unwieldy to the operator because of the interconnect schemes used in connecting to the transducer handle. Several new transducers have been developed using new connection technology. A 40 x 40 = 1,600 element, 3.5 MHz array was fabricated with 256 transmit and 256 receive elements. A 60 x 60 = 3,600 element 5.0 MHz array was constructed with 248 transmit and 256 receive elements. An 80 x 80 = 6,400 element, 2.5 MHz array was fabricated with 256 transmit and 208receive elements. 2-D transducer arrays were also developed for volumetric scanning in an intra cardiac catheter, a 10 x 10 = 100 element 5.0 MHz forward-looking array and an 11 x 13 = 143 element 5.0 MHz side-scanning array. The-6dB fractional bandwidths for the different arrays varied from 50% to 63%, and the 50 omega insertion loss for all the transducers was about-64 dB. The transducers were used to generate real-time volumetric images in phantoms and in vivo using the Duke University real time volumetric imaging system, which is capable of generating multiple planes at any desired angle and depth within the pyramidal volume.

  18. Effects of Different Reconstruction Parameters on CT Volumetric Measurement 
of Pulmonary Nodules

    Directory of Open Access Journals (Sweden)

    Rongrong YANG

    2012-02-01

    Full Text Available Background and objective It has been proven that volumetric measurements could detect subtle changes in small pulmonary nodules in serial CT scans, and thus may play an important role in the follow-up of indeterminate pulmonary nodules and in differentiating malignant nodules from benign nodules. The current study aims to evaluate the effects of different reconstruction parameters on the volumetric measurements of pulmonary nodules in chest CT scans. Methods Thirty subjects who underwent chest CT scan because of indeterminate pulmonary nodules in General Hospital of Tianjin Medical University from December 2009 to August 2011 were retrospectively analyzed. A total of 52 pulmonary nodules were included, and all CT data were reconstructed using three reconstruction algorithms and three slice thicknesses. The volumetric measurements of the nodules were performed using the advanced lung analysis (ALA software. The effects of the reconstruction algorithms, slice thicknesses, and nodule diameters on the volumetric measurements were assessed using the multivariate analysis of variance for repeated measures, the correlation analysis, and the Bland-Altman method. Results The reconstruction algorithms (F=13.6, P<0.001 and slice thicknesses (F=4.4, P=0.02 had significant effects on the measured volume of pulmonary nodules. In addition, the coefficients of variation of nine measurements were inversely related with nodule diameter (r=-0.814, P<0.001. The volume measured at the 2.5 mm slice thickness had poor agreement with the volumes measured at 1.25 mm and 0.625 mm, respectively. Moreover, the best agreement was achieved between the slice thicknesses of 1.25 mm and 0.625 mm using the bone algorithm. Conclusion Reconstruction algorithms and slice thicknesses have significant impacts on the volumetric measurements of lung nodules, especially for the small nodules. Therefore, the reconstruction setting in serial CT scans should be consistent in the follow

  19. 容量法测定方铅矿中高含量银%Volumetric Determination of Silver in Galena Ore

    Institute of Scientific and Technical Information of China (English)

    刘茂荣

    2001-01-01

    A method for KI volumetric determination of high content silver in galena was reported in this paper. Samples with high contents of silicon and lead were decomposed with HNO3-H2SO4-HF.Acidity for the KI volumetric determination of silver was also tested. The results show that in 1.6 mol/L HNO3 medium silver reacts with potassium iodide and forms silver iodide precipitate. The recovery of standard addition for silver by this method is 97.8%~100.4% with precision of 0.92% RSD (n=11). The method is suitable for the dissolution of silver in silicon-bearing silver ores and kerargyrite ores and has been applied to the determination of high content of silver in ores.%报道了采用HNO3-H2SO4-HF溶样,KI容量法测定硅、铅含量较高样品中高含量银的方法。试验了滴定反应的酸度条件。在1.6 mol/L"HNO3介质中,银与碘化钾反应,生成碘化银沉淀。银的标准加入回收率为97.8%~100.4%。精密度试验,相对标准偏差为0.92%(n=11)。该法可溶解含硅银矿及角银矿中的银。方法已被应用于测定矿石中高含量银。

  20. INTEGRATED PURIFICATION OF VENTILATED AIR IN AIR LAYERS OF DAMP BUILDING STRUCTURES

    Directory of Open Access Journals (Sweden)

    V. V. Shitov

    2011-04-01

    Full Text Available Problem statement. Intensive wear of the structure bearing elements in premises with high moisture content in ventilated air is associated with cyclic changes in temperature and humidity indicators of steam-air environment; hence, the problem of ventilated air treatment in such premises is topical.Results. The design of device for integrated purification of atmospheric ventilated air from fine-dispersed pollutants in premise with high moisture content in indoor air is developed.Conclusions. The proposed device provides reliable and long-term operation of bearing building elements.

  1. Comparison of the relationship between bone marrow adipose tissue and volumetric bone mineral density in children and adults.

    Science.gov (United States)

    Shen, Wei; Velasquez, Gilbert; Chen, Jun; Jin, Ye; Heymsfield, Steven B; Gallagher, Dympna; Pi-Sunyer, F Xavier

    2014-01-01

    Several large-scale studies have reported the presence of an inverse relationship between bone mineral density (BMD) and bone marrow adipose tissue (BMAT) in adults. We aim to determine if there is an inverse relationship between pelvic volumetric BMD (vBMD) and pelvic BMAT in children and to compare this relationship in children and adults. Pelvic BMAT and bone volume (BV) was evaluated in 181 healthy children (5-17yr) and 495 healthy adults (≥18yr) with whole-body magnetic resonance imaging (MRI). Pelvic vBMD was calculated using whole-body dual-energy X-ray absorptiometry to measure pelvic bone mineral content and MRI-measured BV. An inverse correlation was found between pelvic BMAT and pelvic vBMD in both children (r=-0.374, pBMAT as the independent variable, being a child or adult neither significantly contribute to the pelvic BMD (p=0.995) nor did its interaction with pelvic BMAT (p=0.415). The inverse relationship observed between pelvic vBMD and pelvic BMAT in children extends previous findings that found the inverse relationship to exist in adults and provides further support for a reciprocal relationship between adipocytes and osteoblasts.

  2. Research on the methods to determine metallic aluminum content in aluminum nanoparticles

    Energy Technology Data Exchange (ETDEWEB)

    Chen Liang [State Key Lab of Materials Forming Simulation and Die and Mould Technology, Huazhong University of Science and Technology, Wuhan 430074 (China); Material Structure Department, Changjiang River Scientific Research Institute, Wuhan 430010 (China); Song Wulin, E-mail: wulins@126.com [State Key Lab of Materials Forming Simulation and Die and Mould Technology, Huazhong University of Science and Technology, Wuhan 430074 (China) and Analytical and Testing Center, Huazhong University of Science and Technology, Wuhan 430074 (China); Lv Jie [State Key Lab of Materials Forming Simulation and Die and Mould Technology, Huazhong University of Science and Technology, Wuhan 430074 (China); Chen Xia [Analytical and Testing Center, Huazhong University of Science and Technology, Wuhan 430074 (China); Xie Changsheng [State Key Lab of Materials Forming Simulation and Die and Mould Technology, Huazhong University of Science and Technology, Wuhan 430074 (China)

    2010-04-15

    The high reactivity of aluminum nanoparticles (ANPs) made the determination of their metallic aluminum (Al) content difficult. Volumetric, thermogravimetry and permanganatometric methods were utilized to determine Al content. The reacted solution after volumetric measurement was further studied by transmission electron microscopy (TEM) and select area electron diffraction (SAED), which revealed that there were unreacted Al particles. Peaks indexed to metallic Al were found in the X-ray diffraction (XRD) pattern of the powders after thermogravimetry analysis (TGA). The side reactions between ANPs and water made the result of permanganatometric measurement underestimated as by the former methods. A modified titration method, using anhydrous alcohol as solvent, was performed to reduce the influence of water. The Al content of the ANPs produced by electro-exploded wire using this method was consistent with the quantitative phase analysis by Rietveld refinement.

  3. Impacts Of Passive Removal Materials On Indoor Air Quality

    DEFF Research Database (Denmark)

    Darling, Erin; Cros, Clement; Wargocki, Pawel

    2011-01-01

    Indoor air quality (IAQ) was determined in the presence of eight combinations of building materials with and without ozone. Air samples were collected in twin 30 m3 chambers to assess the C5 to C10 aldehyde content of the air while a panel of 18 to 23 human subjects assessed air quality using a c...

  4. Gas sorption and the consequent volumetric and permeability change of coal

    Science.gov (United States)

    Lin, Wenjuan

    Experimental and numerical investigations of gas sorption on coal, and the subsequent volumetric and permeability changes of the coal were conducted. The goals of the study were to investigate the magnitude of permeability change caused by gas sorption, and develop an algorithm to simulate numerically gas sorption and sorption-induced permeability change. The amount of gas sorption and the subsequent volumetric and permeability change of coal samples as a function of pore pressure and injection gas composition were measured in the laboratory. A constant effective confining pressure (difference between the confining pressure and pore pressure) was maintained in the process of the experiments; therefore, the role of effective stress on permeability was eliminated. Several gases, including pure CO2, pure N2, and binary mixtures of CO2 and N2 of various compositions were used as the injection gas. The coal sample was first allowed to adsorb an injection gas fully at a particular pressure. The total amount (moles) of adsorption was calculated based on a volumetric method. After adsorption equilibrium was reached, gas samples were taken from the equilibrium gaseous phase and analyzed afterwards. The composition of the gaseous phase prior to and after the adsorption was used to calculate the composition of the adsorbed phase based on material balance. Permeability of the sample was then measured by flowing the injection gas through the core at varying pressure gradient or varying flow rate, and an average permeability was obtained based on Darcy's law for compressible systems. The change of the total volume of the core was monitored and recorded in the whole process of the experiment. Volumetric strain was thereby calculated. Experimental results showed that the greater the pressure the greater the amount of adsorption for all tested gases. At the same pressure, the amount of adsorption was greater for CO2 than N2. For the binary mixtures, the greater the fraction of CO 2

  5. Pneumatization of the temporal portion of the zygomatic arch: The contribution of computed tomography to the reconstruction in volumetric two-dimensional and three-dimensional, with the aid of image rendering protocols

    Directory of Open Access Journals (Sweden)

    C M Romano-Sousa

    2015-01-01

    Full Text Available Pneumatization refers to the asymptomatic development of cavities containing air within them. There is great variability in the extent of temporal bone pneumatization. Nevertheless, in a few cases it extends to the zygomatic process. Images are presented in which the panoramic radiograph and hypocycloidal tomography reveal this variation from the norm, to which professionals must be alert, since the images may simulate the presence of pathology. In this case report we describe the presence of pneumatization of the petrous and zygomatic portions of the temporal bone, demonstrating the contribution of CT to reconstruction in volumetric 2D and 3D, with the aid of image rendering protocols.

  6. Hot Air Drying of Green Table Olives

    Directory of Open Access Journals (Sweden)

    Sayit Sargin

    2005-01-01

    Full Text Available The characteristics of hot air-drying of green table olives (Domat variety by using a tray dryer were studied. Air temperature varied from 40 to 70 °C with an air velocity of 1 m/s. Drying rate curves were determined and quality of dried green olives was evaluated by instrumental analysis (bulk density, particle density, porosity, shrinkage, moisture content, water activity, colour value, protein content, oil content, peroxide value and acidity. Consumers’ acceptance test and microbiological analysis were also applied.

  7. Volumetric response classification in metastatic solid tumors on MSCT: Initial results in a whole-body setting

    Energy Technology Data Exchange (ETDEWEB)

    Wulff, A.M., E-mail: a.wulff@rad.uni-kiel.de [Klinik für Diagnostische Radiologie, Arnold-Heller-Straße 3, Haus 23, 24105 Kiel (Germany); Fabel, M. [Klinik für Diagnostische Radiologie, Arnold-Heller-Straße 3, Haus 23, 24105 Kiel (Germany); Freitag-Wolf, S., E-mail: freitag@medinfo.uni-kiel.de [Institut für Medizinische Informatik und Statistik, Brunswiker Str. 10, 24105 Kiel (Germany); Tepper, M., E-mail: m.tepper@rad.uni-kiel.de [Klinik für Diagnostische Radiologie, Arnold-Heller-Straße 3, Haus 23, 24105 Kiel (Germany); Knabe, H.M., E-mail: h.knabe@rad.uni-kiel.de [Klinik für Diagnostische Radiologie, Arnold-Heller-Straße 3, Haus 23, 24105 Kiel (Germany); Schäfer, J.P., E-mail: jp.schaefer@rad.uni-kiel.de [Klinik für Diagnostische Radiologie, Arnold-Heller-Straße 3, Haus 23, 24105 Kiel (Germany); Jansen, O., E-mail: o.jansen@neurorad.uni-kiel.de [Klinik für Diagnostische Radiologie, Arnold-Heller-Straße 3, Haus 23, 24105 Kiel (Germany); Bolte, H., E-mail: hendrik.bolte@ukmuenster.de [Klinik für Nuklearmedizin, Albert-Schweitzer-Campus 1, Gebäude A1, 48149 Münster (Germany)

    2013-10-01

    Purpose: To examine technical parameters of measurement accuracy and differences in tumor response classification using RECIST 1.1 and volumetric assessment in three common metastasis types (lung nodules, liver lesions, lymph node metastasis) simultaneously. Materials and methods: 56 consecutive patients (32 female) aged 41–82 years with a wide range of metastatic solid tumors were examined with MSCT for baseline and follow up. Images were evaluated by three experienced radiologists using manual measurements and semi-automatic lesion segmentation. Institutional ethics review was obtained and all patients gave written informed consent. Data analysis comprised interobserver variability operationalized as coefficient of variation and categorical response classification according to RECIST 1.1 for both manual and volumetric measures. Continuous data were assessed for statistical significance with Wilcoxon signed-rank test and categorical data with Fleiss kappa. Results: Interobserver variability was 6.3% (IQR 4.6%) for manual and 4.1% (IQR 4.4%) for volumetrically obtained sum of relevant diameters (p < 0.05, corrected). 4–8 patients’ response to therapy was classified differently across observers by using volumetry compared to standard manual measurements. Fleiss kappa revealed no significant difference in categorical agreement of response classification between manual (0.7558) and volumetric (0.7623) measurements. Conclusion: Under standard RECIST thresholds there was no advantage of volumetric compared to manual response evaluation. However volumetric assessment yielded significantly lower interobserver variability. This may allow narrower thresholds for volumetric response classification in the future.

  8. Use of Water Content Reflectometers in Bioinfiltration/Bioretention to Measure Water Movement and Estimate Evapotranspiration - abstract

    Science.gov (United States)

    Most bioinfiltration/bioretention models assume runoff is evenly distributed across the surface area and after the engineered fill media is no longer saturated, the volumetric water content (VWC) is constant throughout the media profile and at field capacity. Four to nine water ...

  9. 4D ultrafast ultrasound flow imaging: in vivo quantification of arterial volumetric flow rate in a single heartbeat

    Science.gov (United States)

    Correia, Mafalda; Provost, Jean; Tanter, Mickael; Pernot, Mathieu

    2016-12-01

    We present herein 4D ultrafast ultrasound flow imaging, a novel ultrasound-based volumetric imaging technique for the quantitative mapping of blood flow. Complete volumetric blood flow distribution imaging was achieved through 2D tilted plane-wave insonification, 2D multi-angle cross-beam beamforming, and 3D vector Doppler velocity components estimation by least-squares fitting. 4D ultrafast ultrasound flow imaging was performed in large volumetric fields of view at very high volume rate (>4000 volumes s-1) using a 1024-channel 4D ultrafast ultrasound scanner and a 2D matrix-array transducer. The precision of the technique was evaluated in vitro by using 3D velocity vector maps to estimate volumetric flow rates in a vessel phantom. Volumetric Flow rate errors of less than 5% were found when volumetric flow rates and peak velocities were respectively less than 360 ml min-1 and 100 cm s-1. The average volumetric flow rate error increased to 18.3% when volumetric flow rates and peak velocities were up to 490 ml min-1 and 1.3 m s-1, respectively. The in vivo feasibility of the technique was shown in the carotid arteries of two healthy volunteers. The 3D blood flow velocity distribution was assessed during one cardiac cycle in a full volume and it was used to quantify volumetric flow rates (375  ±  57 ml min-1 and 275  ±  43 ml min-1). Finally, the formation of 3D vortices at the carotid artery bifurcation was imaged at high volume rates.

  10. Influence of Cobb Angle and ISIS2 Surface Topography Volumetric Asymmetry on Scoliosis Research Society-22 Outcome Scores in Scoliosis.

    Science.gov (United States)

    Brewer, Paul; Berryman, Fiona; Baker, De; Pynsent, Paul; Gardner, Adrian

    2013-11-01

    Retrospective sequential patient series. To establish the relationship between the magnitude of the deformity in scoliosis and patients' perception of their condition, as measured with Scoliosis Research Society-22 scores. A total of 93 untreated patients with adolescent idiopathic scoliosis were included retrospectively. The Cobb angle was measured from a plain radiograph, and volumetric asymmetry was measured by ISIS2 surface topography. The association between Scoliosis Research Society scores for function, pain, self-image, and mental health against Cobb angle and volumetric asymmetry was investigated using the Pearson correlation coefficient. Correlation of both Cobb angle and volumetric asymmetry with function and pain was weak (all self-image, was higher, although still moderate (-.37 for Cobb angle and -.44 for volumetric asymmetry). Both were statistically significant (Cobb angle, p = .0002; volumetric asymmetry; p = .00001). Cobb angle contributed 13.8% to the linear relationship with self-image, whereas volumetric asymmetry contributed 19.3%. For mental health, correlation was statistically significant with Cobb angle (p = .011) and volumetric asymmetry (p = .0005), but the correlation was low to moderate (-.26 and -.35, respectively). Cobb angle contributed 6.9% to the linear relationship with mental health, whereas volumetric asymmetry contributed 12.4%. Volumetric asymmetry correlates better with both mental health and self-image compared with Cobb angle, but the correlation was only moderate. This study suggests that a patient's own perception of self-image and mental health is multifactorial and not completely explained through present objective measurements of the size of the deformity. This helps to explain the difficulties in any objective analysis of a problem with multifactorial perception issues. Further study is required to investigate other physical aspects of the deformity that may have a role in how patients view themselves. Copyright

  11. Volumetric analysis of complex lunar craters - Implications for basin ring formation

    Science.gov (United States)

    Hale, W. S.; Grieve, R. A. F.

    1982-01-01

    The crater to basin transition in complex lunar craters is characterized by combining morphological and volumetric analyses of their central peaks with subsurface data from terrestrial complex impact structures which suggest that the amount of uplifted material, as judged from its depth of origin, continues to increase with increasing rim diameter. This latter phenomenon implies that a redistribution of uplifted material away from a centralized peak may occur in the larger craters. The morphological and volumetric changes described occur over a rim diameter range of 51-80 km, which is considerably lower than the previously proposed range for the crater to basin transition of 140-175 km. Evidence is given in support of a crater to basin transition which begins at 51-80 km, and is characterized by a relative reduction in central peak volume and a development of rings of floor roughening which may be precursors of peak ring development.

  12. Volumetric characteristics and compactability of asphalt rubber mixtures with organic warm mix asphalt additives

    Directory of Open Access Journals (Sweden)

    A. M. Rodríguez-Alloza

    2017-04-01

    Full Text Available Warm Mix Asphalt (WMA refers to technologies that reduce manufacturing and compaction temperatures of asphalt mixtures allowing lower energy consumption and reducing greenhouse gas emissions from asphalt plants. These benefits, combined with the effective reuse of a solid waste product, make asphalt rubber (AR mixtures with WMA additives an excellent environmentally-friendly material for road construction. The effect of WMA additives on rubberized mixtures has not yet been established in detail and the lower mixing/compaction temperatures of these mixtures may result in insufficient compaction. In this sense, the present study uses a series of laboratory tests to evaluate the volumetric characteristics and compactability of AR mixtures with organic additives when production/compaction temperatures are decreased. The results of this study indicate that the additives selected can decrease the mixing/compaction temperatures without compromising the volumetric characteristics and compactability.

  13. Open Volumetric Mesh-An Efficient Data Structure for Tetrahedral and Hexa-hedral Meshes

    Institute of Scientific and Technical Information of China (English)

    XIAN Chu-hua; LI Gui-qing; GAO Shu-ming

    2013-01-01

    This work introduces a scalable and efficient topological structure for tetrahedral and hexahedral meshes. The design of the data structure aims at maximal flexibility and high performance. It provides a high scalability by using hierarchical representa-tions of topological elements. The proposed data structure is array-based, and it is a compact representation of the half-edge data structure for volume elements and half-face data structure for volumetric meshes. This guarantees constant access time to the neighbors of the topological elements. In addition, an open-source implementation named Open Volumetric Mesh (OVM) of the pro-posed data structure is written in C++using generic programming concepts.

  14. Light-Curing Volumetric Shrinkage in Dimethacrylate-Based Dental Composites by Nanoindentation and PAL Study

    Science.gov (United States)

    Shpotyuk, Olha; Adamiak, Stanislaw; Bezvushko, Elvira; Cebulski, Jozef; Iskiv, Maryana; Shpotyuk, Oleh; Balitska, Valentina

    2017-01-01

    Light-curing volumetric shrinkage in dimethacrylate-based dental resin composites Dipol® is examined through comprehensive kinetics research employing nanoindentation measurements and nanoscale atomic-deficient study with lifetime spectroscopy of annihilating positrons. Photopolymerization kinetics determined through nanoindentation testing is shown to be described via single-exponential relaxation function with character time constants reaching respectively 15.0 and 18.7 s for nanohardness and elastic modulus. Atomic-deficient characteristics of composites are extracted from positron lifetime spectra parameterized employing unconstrained x3-term fitting. The tested photopolymerization kinetics can be adequately reflected in time-dependent changes observed in average positron lifetime (with 17.9 s time constant) and fractional free volume of positronium traps (with 18.6 s time constant). This correlation proves that fragmentation of free-volume positronium-trapping sites accompanied by partial positronium-to-positron traps conversion determines the light-curing volumetric shrinkage in the studied composites.

  15. Computational determination of absorbed dose distributions from multiple volumetric gamma ray sources

    Science.gov (United States)

    Zhou, Chuanyu; Inanc, Feyzi

    2002-05-01

    Determination of absorbed dose distributions is very important in brachytherapy procedures. The typical computation involves superposition of absorbed dose distributions from a single seed to compute the combined absorbed dose distribution formed by multiple seeds. This approach does not account for the shadow effect caused by the metallic nature of volumetric radioactive seeds. Since this shadow effect will cause deviations from the targeted dose distribution, it may have important implications on the success of the procedures. We demonstrated accuracy of our deterministic algorithms for isotropic point sources in the past. We will show that we now have the capability of computing absorbed dose distributions from multiple volumetric seeds and demonstrate that our results are quite close to the results published in the literature.

  16. GPU-based Scalable Volumetric Reconstruction for Multi-view Stereo

    Energy Technology Data Exchange (ETDEWEB)

    Kim, H; Duchaineau, M; Max, N

    2011-09-21

    We present a new scalable volumetric reconstruction algorithm for multi-view stereo using a graphics processing unit (GPU). It is an effectively parallelized GPU algorithm that simultaneously uses a large number of GPU threads, each of which performs voxel carving, in order to integrate depth maps with images from multiple views. Each depth map, triangulated from pair-wise semi-dense correspondences, represents a view-dependent surface of the scene. This algorithm also provides scalability for large-scale scene reconstruction in a high resolution voxel grid by utilizing streaming and parallel computation. The output is a photo-realistic 3D scene model in a volumetric or point-based representation. We demonstrate the effectiveness and the speed of our algorithm with a synthetic scene and real urban/outdoor scenes. Our method can also be integrated with existing multi-view stereo algorithms such as PMVS2 to fill holes or gaps in textureless regions.

  17. Volumetric properties of binary mixtures of benzene with cyano-based ionic liquids

    Science.gov (United States)

    Gonfa, Girma; Bustam, Mohamad Azmi; Moniruzzaman, Muhammad; Murugesan, Thanabalan

    2014-10-01

    The objective of this study is to investigate the volumetric properties of the binary mixtures comprised benzene and two ionic liquids, 1-butyl-3-methylimidazolium thiocyanate ([BMIM][SCN]) and 1-butyl-3-methyl- imidazolium dicyanamide ([ BMIM ][ N ( CN )2]( . Densities (ρ) and viscosities (μ) of the binary mixtures were measured over a temperature range of 293.15 to 323.15 K and at atmospheric pressure. Excess molar volumes and viscosity deviations were calculated from the experimental densities and viscosities values. The volumetric properties of the mixtures were changed significantly with the change of compositions and temperatures. It was also found that the value of excess molar volume and viscosity deviations were negative (-ve) over the entire range of compositions. The results have been interpreted in terms of molecular interactions of ILs and benzene.

  18. Holographic time-resolved particle tracking by means of three-dimensional volumetric deconvolution

    CERN Document Server

    Latychevskaia, Tatiana

    2014-01-01

    Holographic particle image velocimetry allows tracking particle trajectories in time and space by means of holography. However, the drawback of the technique is that in the three-dimensional particle distribution reconstructed from a hologram, the individual particles can hardly be resolved due to the superimposed out-of-focus signal from neighboring particles. We demonstrate here a three-dimensional volumetric deconvolution applied to the reconstructed wavefront which results in resolving all particles simultaneously in three-dimensions. Moreover, we apply the three-dimensional volumetric deconvolution to reconstructions of a time-dependent sequence of holograms of an ensemble of polystyrene spheres moving in water. From each hologram we simultaneously resolve all particles in the ensemble in three dimensions and from the sequence of holograms we obtain the time-resolved trajectories of individual polystyrene spheres.

  19. Development of a Diver-Operated Single Camera Volumetric Velocimetry System

    Science.gov (United States)

    Troutman, Valerie; Dabiri, John

    2016-11-01

    The capabilities of a single camera, volumetric velocimetry system for in situ measurement in marine environments are demonstrated by imaging a well-characterized flow in a laboratory environment. This work represents the first stages in the design of a SCUBA-diver operated system to study organisms and biological processes under the natural light in the water column. This system is primarily composed of a volumetric particle tracking diagnostic to investigate fluid-animal interactions. A target domain size of a 20 cm sided cube is sought as a key design feature for the capability of capturing the flow around a variety of benthic and freely swimming organisms. The integration of the particle tracking system with additional diagnostics will be discussed.

  20. Tunable Gravimetric and Volumetric Hydrogen Storage Capacities in Polyhedral Oligomeric Silsesquioxane Frameworks.

    Science.gov (United States)

    Deshmukh, Amol; Chiu, Cheng-Chau; Chen, Yun-Wen; Kuo, Jer-Lai

    2016-09-28

    We study the hydrogen adsorption in porous frameworks composed of silsesquioxane cages linked via boron substituted aromatic structures by first-principles modeling. Such polyhedral oligomeric silsesquioxane (POSS) frameworks can be further modified by decorating them with metal atoms binding to the ring structures of the linkers. We have considered Sc- and Ti-doped frameworks which bind H2 via so-called Kubas interaction between hydrogen molecules and transition metal atoms. It will be demonstrated that the maximum H2 gravimetric capacity can be improved to more than 7.5 wt % by using longer linkers with more ring structures. However, the maximum H2 volumetric capacity can be tuned to more than 70 g/L by varying the size of silsesquioxane cages. We are optimistic that by varying the building blocks, POSS frameworks can be modified to meet the targets for the gravimetric and volumetric capacities set by the U.S. Department of Energy.

  1. A comparative study in treating two VOC mixtures in trickle bed air biofilters.

    Science.gov (United States)

    Cai, Zhangli; Kim, Daekeun; Sorial, George A

    2007-06-01

    Two independent parallel trickling bed air biofilters (TBABs) ("A" and "B") with two different typical VOC mixtures were investigated. Toluene, styrene, methyl ethyl ketone (MEK), and methyl isobutyl ketone (MIBK) were the target VOCs in the mixtures. Biofilter "A" was fed equal molar ratio of the VOCs and biofilter "B" was fed a mixture based on EPA 2003 emission report. Backwashing and substrate starvation operation were conducted as biomass control. Biofilter "A" and "B" maintained 99% overall removal efficiency for influent concentration up to 500 and 300 ppmv under backwashing operating condition, respectively. The starvation study indicated that it can be an effective biomass control for influent concentrations up to 250 ppmv for biofilter "A" and 300 ppmv for "B". Re-acclimation of biofilter performance was delayed with increase of influent concentration for both biofilters. Starvation operation helped the biofilter to recover at low concentrations and delayed re-acclimation at high concentrations. Furthermore, re-acclamation for biofilter "B" was delayed due to its high toluene content as compared to biofilter "A". The pseudo first-order removal rate constant decreased with increase of volumetric loading rate for both biofilters. MEK and MIBK were completely removed in the upper 3/8 media depth. While biofilter depth utilization for the removal of styrene and toluene increased with increase of influent concentrations for both biofilters. However, toluene removal utilized more biofilter depth for biofilter "B" as compared to biofilter "A".

  2. Poly(ethylenimine)-Functionalized Monolithic Alumina Honeycomb Adsorbents for CO2 Capture from Air.

    Science.gov (United States)

    Sakwa-Novak, Miles A; Yoo, Chun-Jae; Tan, Shuai; Rashidi, Fereshteh; Jones, Christopher W

    2016-07-21

    The development of practical and effective gas-solid contactors is an important area in the development of CO2 capture technologies. Target CO2 capture applications, such as postcombustion carbon capture and sequestration (CCS) from power plant flue gases or CO2 extraction directly from ambient air (DAC), require high flow rates of gas to be processed at low cost. Extruded monolithic honeycomb structures, such as those employed in the catalytic converters of automobiles, have excellent potential as structured contactors for CO2 adsorption applications because of the low pressure drop imposed on fluid moving through the straight channels of such structures. Here, we report the impregnation of poly(ethylenimine) (PEI), an effective aminopolymer reported commonly for CO2 separation, into extruded monolithic alumina to form structured CO2 sorbents. These structured sorbents are first prepared on a small scale, characterized thoroughly, and compared with powder sorbents with a similar composition. Despite consistent differences observed in the filling of mesopores with PEI between the monolithic and powder sorbents, their performance in CO2 adsorption is similar across a range of PEI contents. A larger monolithic cylinder (1 inch diameter, 4 inch length) is evaluated under conditions closer to those that might be used in large-scale applications and shows a similar performance to the smaller monoliths and powders tested initially. This larger structure is evaluated over five cycles of CO2 adsorption and steam desorption and demonstrates a volumetric capacity of 350 molCO2  m-3monolith and an equilibration time of 350 min under a 0.4 m s(-1) linear flow velocity through the monolith channels using 400 ppm CO2 in N2 as the adsorption gas at 30 °C. This volumetric capacity surpasses that of a similar technology considered previously, which suggested that CO2 could be removed from air at an operating cost as low as $100 per ton.

  3. Teores e aporte de nutrientes na serapilheira de Pinus taeda L., e sua relação com a temperatura do ar e pluviosidade Contents and input of nutrients in Pinus taeda L. Litter related to air temperature and rainfall

    Directory of Open Access Journals (Sweden)

    Márcio Viera

    2010-02-01

    Full Text Available O objetivo deste estudo foi avaliar os teores e o aporte de nutrientes ao piso florestal num povoamento de Pinus taeda L. e sua relação com a temperatura do ar e pluviosidade, implantado em área anteriormente ocupada por campo nativo, na cidade de Cambará do Sul, RS, através da queda de serapilheira, avaliado durante um período de três anos, contados a partir do quinto ao sétimo ano de idade do povoamento. A serapilheira foi coletada mensalmente através de coletores de 1,0 m² (1,0 x 1,0 m, durante o período compreendido de abril/2004 a março/2007. Após cada coleta, as amostras de serapilheira foram analisadas quimicamente, quanto aos teores de macro e micronutrientes. Os teores de K, Mg e Cu correlacionaram-se positivamente (p The objective of this study was to evaluate the contents and input of nutrients to forest floor in a Pinus taeda L. stand and the relation with rainfall and air temperature, in an area previously occupied with native grass, in Cambará do Sul, RS, through litterfall, evaluated during a three-year period, from the 5th to the 7th year of the stand. Litter was monthly collected in 1.0 m² (1.0 x 1.0 m collectors, from April/ 2004 to March/2007. After each collection, litter samples were chemically analyzed for macro and micronutrients. The contents of K, Mg and Cu showed a positive correlation (p < 0,05 with air temperature, while Fe (p< 0.01, Mn and Zn (p < 0,05 showed a negative correlation with this climatic variable. The contents of N and K showed a negative correlation (p < 0.01 e p < 0,05, respectively. The contents of K, Mg and Cu showed a positive correlation (p < 0,05 with rainfall and the contents of S showed a positive correlation (p < 0,05 with air temperature, while the contents of Fe (p < 0.01, Mn and Zn (p < 0,05 showed a negative correlation with this variable.The contents of N and K showed a negative correlation (p < 0.01 and p < 0,05, respectively with litter amount monthly deposited

  4. The Simulation of High Reynolds Number Cavity Flow Based on Fractional Volumetric Lattice Boltzmann Method

    Institute of Scientific and Technical Information of China (English)

    HAN Shan-ling; ZHU Ping; LIN Zhong-qin

    2005-01-01

    The fractional volumetric lattice Boltzmann method with much better stability was used to simulate two dimensional cavity flows. Because the effective viscosity was reduced by the fraction factor, it is very effective forsimulating high Reynolds number flows. Simulations were carried out on a uniform grids system. The stream lines and the velocity profiles obtained from the simulations agree well with the standard lattice Boltzmann method simulations. Comparisons of detailed flow patterns with other studies via location of vortex centers are also satisfactory.

  5. Theoretical and Experimental Estimations of Volumetric Inductive Phase Shift in Breast Cancer Tissue

    Science.gov (United States)

    González, C. A.; Lozano, L. M.; Uscanga, M. C.; Silva, J. G.; Polo, S. M.

    2013-04-01

    Impedance measurements based on magnetic induction for breast cancer detection has been proposed in some studies. This study evaluates theoretical and experimentally the use of a non-invasive technique based on magnetic induction for detection of patho-physiological conditions in breast cancer tissue associated to its volumetric electrical conductivity changes through inductive phase shift measurements. An induction coils-breast 3D pixel model was designed and tested. The model involves two circular coils coaxially centered and a human breast volume centrally placed with respect to the coils. A time-harmonic numerical simulation study addressed the effects of frequency-dependent electrical properties of tumoral tissue on the volumetric inductive phase shift of the breast model measured with the circular coils as inductor and sensor elements. Experimentally; five female volunteer patients with infiltrating ductal carcinoma previously diagnosed by the radiology and oncology departments of the Specialty Clinic for Women of the Mexican Army were measured by an experimental inductive spectrometer and the use of an ergonomic inductor-sensor coil designed to estimate the volumetric inductive phase shift in human breast tissue. Theoretical and experimental inductive phase shift estimations were developed at four frequencies: 0.01, 0.1, 1 and 10 MHz. The theoretical estimations were qualitatively in agreement with the experimental findings. Important increments in volumetric inductive phase shift measurements were evident at 0.01MHz in theoretical and experimental observations. The results suggest that the tested technique has the potential to detect pathological conditions in breast tissue associated to cancer by non-invasive monitoring. Further complementary studies are warranted to confirm the observations.

  6. Optimization of element length for imaging small volumetric reflectors with linear ultrasonic arrays

    OpenAIRE

    Barber, T. S.; Wilcox, P. D.; Nixon, A. D.

    2016-01-01

    A 3D ultrasonic simulation study is presented, aimed at understanding the effect of element length for imaging small volumetric flaws with linear arrays in ultrasonically noisy materials. The geometry of a linear array can be described by the width, pitch and total number of the elements along with the length perpendicular to imaging plane. This paper is concerned with the latter parameter, which tends to be ignored in array optimization studies and is often chosen arbitrarily for industrial ...

  7. Predicting Offshore Swarm Rate Changes by Volumetric Strain Changes in Izu Peninsula, Japan

    Science.gov (United States)

    Kumazawa, T.; Ogata, Y.; Kimura, Y.; Maeda, K.; Kobayashi, A.

    2014-12-01

    The eastern offshore of Izu peninsula is one of the well known volcanic active regions in Japan, where magma intrusions have been observed several times since 1980s monitored by strain-meters located nearby. Major swarm activities have been synchronously associated with coseismic and preseismic significant sizes of a volumetric strain changes (Earthquake Research Committee, 2010). We investigated the background seismicity changes during these earthquake swarms using the nonstationary ETAS model (Kumazawa and Ogata, 2013), and have found the followings. The modified volumetric strain change data by removing the effect of earth tides and precipitation as well as removing coseismic jumps have much higher cross-correlations to the background rates of the ETAS model than to the whole seismicity rate change of the ETAS, and further the strain changes precede the background seismicity by lag of about a day. This relation suggests an enhanced prediction of earthquakes in this region using volumetric strain measurements. Thus we propose an extended ETAS model where the background seismicity rate is predicted by the time series of preceding volumetric strain changes. Our numerical results for Izu region show consistent outcomes throughout the major swarms in this region. References Earthquake Research Committee (2010). Report on "Prediction of seismic activity in the Izu Eastern Region" (in Japanese), http://www.jishin.go.jp/main/yosoku/izu/index.htm Kumazawa, T. and Ogata, Y. (2013). Quantitative description of induced seismic activity before and after the 2011 Tohoku-Oki earthquake by nonstationary ETAS model, J Geophys.Res. 118, 6165-6182.

  8. Development of Mathematical Models for Detecting Micron Scale Volumetric Defects in Thin Film Coatings

    Directory of Open Access Journals (Sweden)

    Gaigals G.

    2016-04-01

    Full Text Available The focus of the present research is to investigate possibilities of volumetric defect detection in thin film coatings on glass substrates by means of high definition imaging with no complex optical systems, such as lenses, and to determine development and construction feasibility of a defectoscope employing the investigated methods. Numerical simulations were used to test the proposed methods. Three theoretical models providing various degrees of accuracy and feasibility were studied.

  9. Simultaneously high gravimetric and volumetric methane uptake characteristics of the metal-organic framework NU-111.

    Science.gov (United States)

    Peng, Yang; Srinivas, Gadipelli; Wilmer, Christopher E; Eryazici, Ibrahim; Snurr, Randall Q; Hupp, Joseph T; Yildirim, Taner; Farha, Omar K

    2013-04-14

    We show that the MOF NU-111 exhibits equally high volumetric and gravimetric methane uptake values, both within ≈75% of the DOE targets at 300 K. Upon reducing the temperature to 270 K, the uptake increases to 0.5 g g(-1) and 284 cc(STP) per cc at 65 bar. Adsorption of CO2 and H2 is also reported. Simulated isotherms are in excellent agreement with those obtained from experiments.

  10. Rapidly-steered single-element ultrasound for real-time volumetric imaging and guidance

    Science.gov (United States)

    Stauber, Mark; Western, Craig; Solek, Roman; Salisbury, Kenneth; Hristov, Dmitre; Schlosser, Jeffrey

    2016-03-01

    Volumetric ultrasound (US) imaging has the potential to provide real-time anatomical imaging with high soft-tissue contrast in a variety of diagnostic and therapeutic guidance applications. However, existing volumetric US machines utilize "wobbling" linear phased array or matrix phased array transducers which are costly to manufacture and necessitate bulky external processing units. To drastically reduce cost, improve portability, and reduce footprint, we propose a rapidly-steered single-element volumetric US imaging system. In this paper we explore the feasibility of this system with a proof-of-concept single-element volumetric US imaging device. The device uses a multi-directional raster-scan technique to generate a series of two-dimensional (2D) slices that were reconstructed into three-dimensional (3D) volumes. At 15 cm depth, 90° lateral field of view (FOV), and 20° elevation FOV, the device produced 20-slice volumes at a rate of 0.8 Hz. Imaging performance was evaluated using an US phantom. Spatial resolution was 2.0 mm, 4.7 mm, and 5.0 mm in the axial, lateral, and elevational directions at 7.5 cm. Relative motion of phantom targets were automatically tracked within US volumes with a mean error of -0.3+/-0.3 mm, -0.3+/-0.3 mm, and -0.1+/-0.5 mm in the axial, lateral, and elevational directions, respectively. The device exhibited a mean spatial distortion error of 0.3+/-0.9 mm, 0.4+/-0.7 mm, and -0.3+/-1.9 in the axial, lateral, and elevational directions. With a production cost near $1000, the performance characteristics of the proposed system make it an ideal candidate for diagnostic and image-guided therapy applications where form factor and low cost are paramount.

  11. A multistage volumetric bar chart chip for visualized quantification of DNA

    OpenAIRE

    Song, Yujun; Wang, Yuanchen; Qin, Lidong

    2013-01-01

    Nucleic acid detection is critical in disease diagnosis as well as in the environmental assays of harmful bacteria or viruses and forensic applications. Current methods for visualized quantification of DNA require costly and sophisticated instruments. Here, we report a multistage propelled volumetric bar chart chip (MV-Chip) for multiplexing and quantitative detection of DNA. Owing to its ‘rocket-like’ propelling reaction, the pre-deposited platinum films could perform cascade amplification a...

  12. Impact of turbocharger non-adiabatic operation on engine volumetric efficiency and turbo lag

    OpenAIRE

    S. Shaaban; Seume, J.

    2012-01-01

    Turbocharger performance significantly affects the thermodynamic properties of the working fluid at engine boundaries and hence engine performance. Heat transfer takes place under all circumstances during turbocharger operation. This heat transfer affects the power produced by the turbine, the power consumed by the compressor, and the engine volumetric efficiency. Therefore, non-adiabatic turbocharger performance can restrict the engine charging process and hence engine performance. The prese...

  13. Impact of Turbocharger Non-Adiabatic Operation on Engine Volumetric Efficiency and Turbo Lag

    OpenAIRE

    S. Shaaban; Seume, J.

    2012-01-01

    Turbocharger performance significantly affects the thermodynamic properties of the working fluid at engine boundaries and hence engine performance. Heat transfer takes place under all circumstances during turbocharger operation. This heat transfer affects the power produced by the turbine, the power consumed by the compressor, and the engine volumetric efficiency. Therefore, non-adiabatic turbocharger performance can restrict the engine charging process and hence engine performance. The prese...

  14. PEMODELAN OBYEK TIGA DIMENSI DARI GAMBAR SINTETIS DUA DIMENSI DENGAN PENDEKATAN VOLUMETRIC

    Directory of Open Access Journals (Sweden)

    Rudy Adipranata

    2005-01-01

    Full Text Available In this paper, we implemented 3D object modeling from 2D input images. Modeling is performed by using volumetric reconstruction approaches by using volumetric reconstruction approaches, the 3D space is tesselated into discrete volumes called voxels. We use voxel coloring method to reconstruct 3D object from synthetic input images by using voxel coloring, we can get photorealistic result and also has advantage to solve occlusion problem that occur in many case of 3D reconstruction. Photorealistic 3D object reconstruction is a challenging problem in computer graphics and still an active area nowadays. Many applications that make use the result of reconstruction, include virtual reality, augmented reality, 3D games, and another 3D applications. Voxel coloring considered the reconstruction problem as a color reconstruction problem, instead of shape reconstruction problem. This method works by discretizing scene space into voxels, then traversed and colored those voxels in special order. The result is photorealitstic 3D object. Abstract in Bahasa Indonesia : Dalam penelitian ini dilakukan implementasi untuk pemodelan obyek tiga dimensi yang berasal dari gambar dua dimensi. Pemodelan ini dilakukan dengan menggunakan pendekatan volumetric. Dengan menggunakan pendekatan volumetric, ruang tiga dimensi dibagi menjadi bentuk diskrit yang disebut voxel. Kemudian pada voxel-voxel tersebut dilakukan metode pewarnaan voxel untuk mendapatkan hasil berupa obyek tiga dimensi yang bersifat photorealistic. Bagaimana memodelkan obyek tiga dimensi untuk menghasilkan hasil photorealistic merupakan masalah yang masih aktif di bidang komputer grafik. Banyak aplikasi lain yang dapat memanfaatkan hasil dari pemodelan tersebut seperti virtual reality, augmented reality dan lain-lain. Pewarnaan voxel merupakan pemodelan obyek tiga dimensi dengan melakukan rekonstruksi warna, bukan rekonstruksi bentuk. Metode ini bekerja dengan cara mendiskritkan obyek menjadi voxel dan

  15. An Autologous Muscle Tissue Expansion Approach for the Treatment of Volumetric Muscle Loss

    Science.gov (United States)

    2015-07-01

    ORIGINAL RESEARCH ARTICLE Open Access An Autologous Muscle Tissue Expansion Approach for the Treatment of Volumetric Muscle Loss Catherine L. Ward...regeneration. But they require ample donor muscle tissue and therefore may be limited in their application for large clinical VML. Here, we tested the...autologous minced grafts for the regeneration of muscle tissue after VML, but indicate the need to identify optimal carrier materials for expansion

  16. Volumetric and superficial characterization of carbon activated; Caracterizacion volumetrica y superficial de carbon activado

    Energy Technology Data Exchange (ETDEWEB)

    Carrera G, L.M.; Garcia S, I.; Jimenez B, J.; Solache R, M.; Lopez M, B.; Bulbulian G, S.; Olguin G, M.T. [Departamento de Quimica, Gerencia de Ciencias Basicas, Instituto Nacional de Investigaciones Nucleares, A.P. 18-1027, 11801 Mexico D.F. (Mexico)

    2000-07-01

    The activated carbon is the resultant material of the calcination process of natural carbonated materials as coconut shells or olive little bones. It is an excellent adsorbent of diluted substances, so much in colloidal form, as in particles form. Those substances are attracted and retained by the carbon surface. In this work is make the volumetric and superficial characterization of activated carbon treated thermically (300 Centigrade) in function of the grain size average. (Author)

  17. The diagnostic contribution of CT volumetric rendering techniques in routine practice

    OpenAIRE

    Perandini Simone; Faccioli N; Zaccarella A; Re T; Mucelli R

    2010-01-01

    Computed tomography (CT) volumetric rendering techniques such as maximum intensity projection (MIP), minimum intensity projection (MinIP), shaded surface display (SSD), volume rendering (VR), and virtual endoscopy (VE) provide added diagnostic capabilities. The diagnostic value of such reconstruction techniques is well documented in literature. These techniques permit the exploration of fine anatomical detail that would be difficult to evaluate using axial reconstructions alone. Although thes...

  18. Comparative analysis of volumetric flow meters used for mass flow estimation in multiphase and multidensity environments

    Science.gov (United States)

    Pedone, Richard; Korman, Valentin; Wiley, John T.

    2006-05-01

    Accurate and reliable multiphase flow measurements are needed for liquid propulsion systems. Existing volumetric flow meters are adequate for flow measurements with well-characterized, clean liquids and gases. However, these technologies are inadequate for multiphase environments, such as cryogenic fluids. Although, properly calibrated turbine flow meters can provide highly accurate and repeatable data, problems are still prevalent with multiphase flows. Limitations are thus placed on the applicability of intrusive turbine flow meters.

  19. Template-assisted low temperature synthesis of functionalized graphene for ultrahigh volumetric performance supercapacitors.

    Science.gov (United States)

    Yan, Jun; Wang, Qian; Wei, Tong; Jiang, Lili; Zhang, Milin; Jing, Xiaoyan; Fan, Zhuangjun

    2014-05-27

    We demonstrated the fabrication of functionalized graphene nanosheets via low temperature (300 °C) treatment of graphite oxide with a slow heating rate using Mg(OH)2 nanosheets as template. Because of its dented sheet with high surface area, a certain amount of oxygen-containing groups, and low pore volume, the as-obtained graphene delivers both ultrahigh specific gravimetric and volumetric capacitances of 456 F g(-1) and 470 F cm(-3), almost 3.7 times and 3.3 times higher than hydrazine reduced graphene, respectively. Especially, the obtained volumetric capacitance is the highest value so far reported for carbon materials in aqueous electrolytes. More importantly, the assembled supercapacitor exhibits an ultrahigh volumetric energy density of 27.2 Wh L(-1), which is among the highest values for carbon materials in aqueous electrolytes, as well as excellent cycling stability with 134% of its initial capacitance after 10,000 cycles. Therefore, the present work holds a great promise for future design and large-scale production of high performance graphene electrodes for portable energy storage devices.

  20. The prognostic role of prenatal MRI volumetric assessment in fetuses with isolated ventriculomegaly.

    Science.gov (United States)

    Gezer, Naciye Sinem; Güleryüz, Handan; Gezer, Cenk; Koçyiğit, Ali; Yeşilırmak, Didem; Ekin, Atalay; Bilgin, Muzaffer; Ertaş, İbrahim Egemen

    2015-01-01

    In this prospective study, we aimed to establish the value of volumetric assessment by prenatal brain MRI in determining the prognosis of fetuses with isolated VM. A total of 23 fetuses with isolated VM were included in the study. Supratentorial cerebral parenchyma volume (PV) and ventricular volume (VV) were measured, and supratentorial ventricular/parenchymal volume (VV/PV) ratios were calculated. Pregnancy and postnatal neurodevelopmental outcomes up to two years of age were obtained and correlated with the volumetric measurements. VV was found to be strongly and positively correlated with ventricular dimension. There was a statistically significant difference between the VV/ PV ratios of the good and poor prognosis groups into which the cases had been categorized. The fetuses with a poor prognosis had a significantly higher VV/PV ratio. Volumetric parenchymal and ventricular measurements obtained by fetal brain MRI may contribute to future clinical studies concerning the evaluation of fetuses with VM and provide an important indicator in cases where management dilemmas arise.

  1. The effect of volumetric (3D) tactile symbols within inclusive tactile maps.

    Science.gov (United States)

    Gual, Jaume; Puyuelo, Marina; Lloveras, Joaquim

    2015-05-01

    Point, linear and areal elements, which are two-dimensional and of a graphic nature, are the morphological elements employed when designing tactile maps and symbols for visually impaired users. However, beyond the two-dimensional domain, there is a fourth group of elements - volumetric elements - which mapmakers do not take sufficiently into account when it comes to designing tactile maps and symbols. This study analyses the effect of including volumetric, or 3D, symbols within a tactile map. In order to do so, the researchers compared two tactile maps. One of them uses only two-dimensional elements and is produced using thermoforming, one of the most popular systems in this field, while the other includes volumetric symbols, thus highlighting the possibilities opened up by 3D printing, a new area of production. The results of the study show that including 3D symbols improves the efficiency and autonomous use of these products. Copyright © 2014 Elsevier Ltd and The Ergonomics Society. All rights reserved.

  2. [Change in condylar and mandibular morphology in juvenile idiopathic arthritis: cone beam volumetric imaging].

    Science.gov (United States)

    Garagiola, Umberto; Mercatali, Lorenzo; Bellintani, Claudio; Fodor, Attila; Farronato, Giampietro; Lőrincz, Adám

    2013-03-01

    The aim of this study is to show the importance of Cone Beam Computerized Tomography to volumetrically quantify TMJ damage in patients with JIA, measuring condylar and mandibular real volumes. 34 children with temporomandibular involvement by Juvenile Idiopathic Arthritis were observed by Cone Beam Computerized Tomography. 4 were excluded because of several imaging noises. The mandible was isolated from others craniofacial structures; the whole mandibular volume and its components' volumes (condyle, ramus, hemibody, hemisymphysis on right side and on left side) has been calculated by a 3D volume rendering technique. The results show a highly significant statistical difference between affected side volumetric values versus normal side volumetric values above all on condyle region (P < 0.01), while they don't show any statistical differences between right side versus left side. The Cone Beam Computerized Tomography represents a huge improvement in understanding of the condyle and mandibular morphological changes, even in the early stages of the Juvenile Idiopathic Arthritis. The JIA can lead in children to temporomandibular joint damage with facial development and growth alterations.

  3. Verbal Memory Decline following DBS for Parkinson’s Disease: Structural Volumetric MRI Relationships

    Science.gov (United States)

    Geevarghese, Ruben; Lumsden, Daniel E.; Costello, Angela; Hulse, Natasha; Ayis, Salma; Samuel, Michael; Ashkan, Keyoumars

    2016-01-01

    Background Parkinson’s disease is a chronic degenerative movement disorder. The mainstay of treatment is medical. In certain patients Deep Brain Stimulation (DBS) may be offered. However, DBS has been associated with post-operative neuropsychology changes, especially in verbal memory. Objectives Firstly, to determine if pre-surgical thalamic and hippocampal volumes were related to verbal memory changes following DBS. Secondly, to determine if clinical factors such as age, duration of symptoms or motor severity (UPDRS Part III score) were related to verbal memory changes. Methods A consecutive group of 40 patients undergoing bilateral Subthalamic Nucleus (STN)-DBS for PD were selected. Brain MRI data was acquired, pre-processed and structural volumetric data was extracted using FSL. Verbal memory test scores for pre- and post-STN-DBS surgery were recorded. Linear regression was used to investigate the relationship between score change and structural volumetric data. Results A significant relationship was demonstrated between change in List Learning test score and thalamic (left, p = 0.02) and hippocampal (left, p = 0.02 and right p = 0.03) volumes. Duration of symptoms was also associated with List Learning score change (p = 0.02 to 0.03). Conclusion Verbal memory score changes appear to have a relationship to pre-surgical MRI structural volumetric data. The findings of this study provide a basis for further research into the use of pre-surgical MRI to counsel PD patients regarding post-surgical verbal memory changes. PMID:27557088

  4. VOLUMETRIC ERROR COMPENSATION IN FIVE-AXIS CNC MACHINING CENTER THROUGH KINEMATICS MODELING OF GEOMETRIC ERROR

    Directory of Open Access Journals (Sweden)

    Pooyan Vahidi Pashsaki

    2016-06-01

    Full Text Available Accuracy of a five-axis CNC machine tool is affected by a vast number of error sources. This paper investigates volumetric error modeling and its compensation to the basis for creation of new tool path for improvement of work pieces accuracy. The volumetric error model of a five-axis machine tool with the configuration RTTTR (tilting head B-axis and rotary table in work piece side A΄ was set up taking into consideration rigid body kinematics and homogeneous transformation matrix, in which 43 error components are included. Volumetric error comprises 43 error components that can separately reduce geometrical and dimensional accuracy of work pieces. The machining accuracy of work piece is guaranteed due to the position of the cutting tool center point (TCP relative to the work piece. The cutting tool is deviated from its ideal position relative to the work piece and machining error is experienced. For compensation process detection of the present tool path and analysis of the RTTTR five-axis CNC machine tools geometrical error, translating current position of component to compensated positions using the Kinematics error model, converting newly created component to new tool paths using the compensation algorithms and finally editing old G-codes using G-code generator algorithm have been employed.

  5. Brain stem and cerebellum volumetric analysis of Machado Joseph disease patients

    Directory of Open Access Journals (Sweden)

    S T Camargos

    2011-01-01

    Full Text Available Machado-Joseph disease, or spinocerebellar ataxia type 3(MJD/SCA3, is the most frequent late onset spinocerebellar ataxia and results from a CAG repeat expansion in the ataxin-3 gene. Previous studies have found correlation between atrophy of cerebellum and brainstem with age and CAG repeats, although no such correlation has been found with disease duration and clinical manifestations. In this study we test the hypothesis that atrophy of cerebellum and brainstem in MJD/SCA3 is related to clinical severity, disease duration and CAG repeat length as well as to other variables such as age and ICARS (International Cooperative Ataxia Rating Scale. Whole brain high resolution MRI and volumetric measurement with cranial volume normalization were obtained from 15 MJD/SCA3 patients and 15 normal, age and sex-matchedcontrols. We applied ICARS and compared the score with volumes and CAG number, disease duration and age. We found significant correlation of both brain stem and cerebellar atrophy with CAG repeat length, age, disease duration and degree of disability. The Spearman rank correlation was stronger with volumetric reduction of the cerebellum than with brain stem. Our data allow us to conclude that volumetric analysis might reveal progressive degeneration after disease onset, which in turn is linked to both age and number of CAG repeat expansions in SCA 3.

  6. Volumetric flow rate comparisons for water and product on pasteurization systems.

    Science.gov (United States)

    Schlesser, J E; Stroup, W H; McKinstry, J A

    1994-04-01

    A flow calibration tube system was assembled to determine the volumetric flow rates for water and various dairy products through a holding tube, using three different flow promotion methods. With the homogenizer, the volumetric flow rates of water and reconstituted skim milk were within 1.5% of each other. With the positive displacement pump, the flow rate for reconstituted skim milk increased compared with that for water as the pressure increased or temperature decreased. The largest increase in flow rate was at 310-kPa gauge and 20 degrees C. On a magnetic flow meter system, the volumetric flow rates of water and reconstituted skim milk were within .5% of the flow rate measured from the volume collected in a calibrated tank. The flow rate of whole milk was similar to that of skim milk on the three flow promoters evaluated. Ice milk mix increased the flow rate of the positive displacement pump, but not the homogenizer and magnetic flow meter system.

  7. Microfabricated pseudocapacitors using Ni(OH)2 electrodes exhibit remarkable volumetric capacitance and energy density

    KAUST Repository

    Kurra, Narendra

    2014-09-10

    Metal hydroxide based microfabricated pseudocapacitors with impressive volumetric stack capacitance and energy density are demonstrated. A combination of top-down photolithographic process and bottom-up chemical synthesis is employed to fabricate the micro-pseudocapacitors (μ-pseudocapacitors). The resulting Ni(OH)2-based devices show several excellent characteristics including high-rate redox activity up to 500 V s-1 and an areal cell capacitance of 16 mF cm-2 corresponding to a volumetric stack capacitance of 325 F cm-3. This volumetric capacitance is two-fold higher than carbon and metal oxide based μ-supercapacitors with interdigitated electrode architecture. Furthermore, these μ-pseudocapacitors show a maximum energy density of 21 mWh cm-3, which is superior to the Li-based thin film batteries. The heterogeneous growth of Ni(OH)2 over the Ni surface during the chemical bath deposition is found to be the key parameter in the formation of uniform monolithic Ni(OH)2 mesoporous nanosheets with vertical orientation, responsible for the remarkable properties of the fabricated devices. Additionally, functional tandem configurations of the μ-pseudocapacitors are shown to be capable of powering a light-emitting diode.

  8. Improving reservoir volumetric estimations in petroleum resource assessment using discovery process models

    Institute of Scientific and Technical Information of China (English)

    Chen Zhuoheng; Osadetz Kirk G.

    2009-01-01

    The reservoir volumetric approach represents a widely accepted, but flawed method of petroleum play resource calculation.In this paper, we propose a combination of techniques that can improve the applicability and quality of the resource estimation.These techniques include: 1) the use of the Multivariate Discovery Process model (MDP) to derive unbiased distribution parameters of reservoir volumetric variables and to reveal correlations among the variables; 2) the use of the Geo-anchored method to estimate simultaneously the number of oil and gas pools in the same play; and 3) the cross-validation of assessment results from different methods.These techniques are illustrated by using an example of crude oil and natural gas resource assessment of the Sverdrup Basin, Canadian Archipelago.The example shows that when direct volumetric measurements of the untested prospects are not available, the MDP model can help derive unbiased estimates of the distribution parameters by using information from the discovered oil and gas accumulations.It also shows that an estimation of the number of oil and gas accumulations and associated size ranges from a discovery process model can provide an alternative and efficient approach when inadequate geological data hinder the estimation.Cross-examination of assessment results derived using different methods allows one to focus on and analyze the causes for the major differences, thus providing a more reliable assessment outcome.

  9. The importance of accurate anatomic assessment for the volumetric analysis of the amygdala

    Directory of Open Access Journals (Sweden)

    L. Bonilha

    2005-03-01

    Full Text Available There is a wide range of values reported in volumetric studies of the amygdala. The use of single plane thick magnetic resonance imaging (MRI may prevent the correct visualization of anatomic landmarks and yield imprecise results. To assess whether there is a difference between volumetric analysis of the amygdala performed with single plane MRI 3-mm slices and with multiplanar analysis of MRI 1-mm slices, we studied healthy subjects and patients with temporal lobe epilepsy. We performed manual delineation of the amygdala on T1-weighted inversion recovery, 3-mm coronal slices and manual delineation of the amygdala on three-dimensional volumetric T1-weighted images with 1-mm slice thickness. The data were compared using a dependent t-test. There was a significant difference between the volumes obtained by the coronal plane-based measurements and the volumes obtained by three-dimensional analysis (P < 0.001. An incorrect estimate of the amygdala volume may preclude a correct analysis of the biological effects of alterations in amygdala volume. Three-dimensional analysis is preferred because it is based on more extensive anatomical assessment and the results are similar to those obtained in post-mortem studies.

  10. Volumetric dimensional changes of dental light-cured dimethacrylate resins after sorption of water or ethanol.

    Science.gov (United States)

    Sideridou, Irini D; Karabela, Maria M; Vouvoudi, Evagelia Ch

    2008-08-01

    This study evaluated the influence of water and ethanol sorption on the volumetric dimensional changes of resins prepared by light curing of Bis-GMA, Bis-EMA, UDMA, TEGDMA or D(3)MA. The resin specimens (15mm diameterx1mm height) were immersed in water or ethanol 37+/-1 degrees C for 30 days. Volumetric changes of specimens were obtained via accurate mass measurements using Archimedes principle. The specimens were reconditioned by dry storage in an oven at 37+/-1 degrees C until constant mass was obtained and then immersed in water or ethanol for 30 days. The volumetric changes of specimens were determined and compared to those obtained from the first sorption. Resins showed similar volume increase during the first and second sorptions of water or ethanol. The volume increase due to water absorption is in the following order: poly-TEGDMA>poly-Bis-GMA>poly-UDMA>poly-Bis-EMA>poly-D(3)MA. On the contrary, the order in ethanol is poly-Bis-GMA>poly-UDMA>poly-TEGDMA>poly-Bis-EMA approximately poly-D(3)MA. The volume increase was found to depend linearly on the amount of water or ethanol absorbed. In the choice of monomers for preparation of composite resin matrix the volume increase in the resin after immersion in water or ethanol must be taken into account. Resins of Bis-EMA and D(3)MA showed the lowest values.

  11. Three-dimensional linear and volumetric analysis of maxillary sinus pneumatization

    Directory of Open Access Journals (Sweden)

    Reham M. Hamdy

    2014-05-01

    Full Text Available Considering the anatomical variability related to the maxillary sinus, its intimate relation to the maxillary posterior teeth and because of all the implications that pneumatization may possess, three-dimensional assessment of maxillary sinus pneumatization is of most usefulness. The aim of this study is to analyze the maxillary sinus dimensions both linearly and volumetrically using cone beam computed tomography (CBCT to assess the maxillary sinus pneumatization. Retrospective analysis of 30 maxillary sinuses belonging to 15 patients’ CBCT scans was performed. Linear and volumetric measurements were conducted and statistically analyzed. The maximum craniocaudal extension of the maxillary sinus was located around the 2nd molar in 93% of the sinuses, while the maximum mediolateral and antroposterior extensions of the maxillary sinus were located at the level of root of zygomatic complex in 90% of sinuses. There was a high correlation between the linear measurements of the right and left sides, where the antroposterior extension of the sinus at level of the nasal floor had the largest correlation (0.89. There was also a high correlation between the Simplant and geometric derived maxillary sinus volumes for both right and left sides (0.98 and 0.96, respectively. The relations of the sinus floor can be accurately assessed on the different orthogonal images obtained through 3D CBCT scan. The geometric method offered a much cheaper, easier, and less sophisticated substitute; therefore, with the availability of software, 3D volumetric measurements are more facilitated.

  12. Dental volumetric tomographical evaluation of location and prevalence of maxillary sinus septa

    Directory of Open Access Journals (Sweden)

    Ibrahim Damlar

    2013-06-01

    Full Text Available Purpose: The aim of this study was to determine the prevalence and location of maxillary sinus septa with the help of dental volumetric tomography. Methods: 760 patients’ 1520 maxillary sinus were evaluated by dental volumetric tomography for detecting maxillary sinus septa. Maxillary sinus was divided into 3 zones (anterior, middle and posterior zones while location of the maxillary sinus septa. Results: 47 of maxillary sinus septa existed in the anterior zone (24.7%, 35 of them in the middle zone (18.4% and 108 of them in the posterior region (56.8%. Conclusion: The formation of the maxillary sinus septa was affected by the existence or lack of the teeth. Correct detection of the presence of maxillary sinus septa was important prior to sinus lifting and dental implant surgery. Dental volumetric tomographical evaluation of maxillary sinus septa was more useful for a correct diagnosis and treatment planning. [Cukurova Med J 2013; 38(3.000: 467-474

  13. A new contrast-assisted method in microcirculation volumetric flow assessment

    Science.gov (United States)

    Lu, Sheng-Yi; Chen, Yung-Sheng; Yeh, Chih-Kuang

    2007-03-01

    Microcirculation volumetric flow rate is a significant index in diseases diagnosis and treatment such as diabetes and cancer. In this study, we propose an integrated algorithm to assess microcirculation volumetric flow rate including estimation of blood perfused area and corresponding flow velocity maps based on high frequency destruction/contrast replenishment imaging technique. The perfused area indicates the blood flow regions including capillaries, arterioles and venules. Due to the echo variance changes between ultrasonic contrast agents (UCAs) pre- and post-destruction two images, the perfused area can be estimated by the correlation-based approach. The flow velocity distribution within the perfused area can be estimated by refilling time-intensity curves (TICs) after UCAs destruction. Most studies introduced the rising exponential model proposed by Wei (1998) to fit the TICs. Nevertheless, we found the TICs profile has a great resemblance to sigmoid function in simulations and in vitro experiments results. Good fitting correlation reveals that sigmoid model was more close to actual fact in describing destruction/contrast replenishment phenomenon. We derived that the saddle point of sigmoid model is proportional to blood flow velocity. A strong linear relationship (R = 0.97) between the actual flow velocities (0.4-2.1 mm/s) and the estimated saddle constants was found in M-mode and B-mode flow phantom experiments. Potential applications of this technique include high-resolution volumetric flow rate assessment in small animal tumor and the evaluation of superficial vasculature in clinical studies.

  14. Crumpled Nitrogen-Doped Graphene for Supercapacitors with High Gravimetric and Volumetric Performances.

    Science.gov (United States)

    Wang, Jie; Ding, Bing; Xu, Yunling; Shen, Laifa; Dou, Hui; Zhang, Xiaogang

    2015-10-14

    Graphene is considered a promising electrochemical capacitors electrode material due to its high surface area and high electrical conductivity. However, restacking interactions between graphene nanosheets significantly decrease the ion-accessible surface area and impede electronic and ionic transfer. This would, in turn, severely hinder the realization of high energy density. Herein, we report a strategy for preparation of few-layer graphene material with abundant crumples and high-level nitrogen doping. The two-dimensional graphene nanosheets (CNG) feature high ion-available surface area, excellent electronic and ion transfer properties, and high packing density, permitting the CNG electrode to exhibit excellent electrochemical performance. In ionic liquid electrolyte, the CNG electrode exhibits gravimetric and volumetric capacitances of 128 F g(-1) and 98 F cm(-3), respectively, achieving gravimetric and volumetric energy densities of 56 Wh kg(-1) and 43 Wh L(-1). The preparation strategy described here provides a new approach for developing a graphene-based supercapacitor with high gravimetric and volumetric energy densities.

  15. Fatigue life estimation for different notched specimens based on the volumetric approach

    Directory of Open Access Journals (Sweden)

    Esmaeili F.

    2010-06-01

    Full Text Available In this paper, the effects of notch radius for different notched specimens has been studied on the values of stress concentration factor, notch strength reduction factor, and fatigue life duration of the specimens. The material which has been selected for this investigation is Al 2024T3 . Volumetric approach has been applied to obtain the values of notch strength reduction factor and results have been compared with those obtained from the Neuber and Peterson methods. Load controlled fatigue tests of mentioned specimens have been conducted on the 250kN servo-hydraulic Zwick/Amsler fatigue testing machine with the frequency of 10Hz. The fatigue lives of the specimens have also been predicted based on the available smooth S-N curve of Al2024-T3 and also the amounts of notch strength reduction factor which have been obtained from volumetric, Neuber and Peterson methods. The values of stress and strain around the notch roots are required to predict the fatigue life of notched specimens, so Ansys finite element code has been used and non-linear analyses have been performed to obtain the stress and strain distributions around the notches. The plastic deformations of the material have been simulated using multi-linear kinematic hardening and cyclic stress-strain relation. The work here shows that the volumetric approach does a very good job for predicting the fatigue life of the notched specimens.

  16. Study of volumetric properties (PVT) of mixtures made of light hydrocarbons (C1-C4), carbon dioxide and hydrogen sulfide - Experimental measurements through a vibrating tube densimeter and modelling; Etude des proprietes volumetriques (PVT) d'hydrocarbures legers (C1-C4), du dioxyde de carbone et de l'hydrogene sulfure. Mesures par densimetrie a tube vibrant et modelisation

    Energy Technology Data Exchange (ETDEWEB)

    Rivollet, F.

    2005-12-15

    Various pollutant contents (i.e. carbon dioxide, hydrogen sulphide or other sulphur products) are found in produced oils. These latter must undergo a number of transformations and purifications. The design and dimensioning of the corresponding units can well be optimized only if one has reliable and accurate data about phase equilibria and volumetric properties and of course reliable and accurate modeling. This work was devoted partly to measurements of volumetric properties on three binary mixtures (ethane - hydrogen sulphide, ethane - propane and carbon dioxide - hydrogen sulphide). These measurements were carried out using equipment, comprising a vibrating tube densimeter (Paar, model DMA 512 P), which was especially designed and built for this work. The binary mixtures were studied in the 253 to 363 K temperature range from at pressures up to either 20 or 40 MPa. Two calibration methods of the vibrating tube were used: the FPMC method (Forced Path Mechanical Calibration) described in the literature and an original method containing neural network, developed herein. The study undertaken about the modeling of volumetric properties made it possible to highlight the inadequacy of the traditional use of cubic equations of state to represent simultaneously volumetric properties and phase equilibria. Among the equations of state investigated, a close attention however was paid to cubic equations of state because of their very great use in the oil field. A new tool was found to adapt cubic equations of state to the simultaneous and satisfactory representation of volumetric properties and phase equilibria. It concerns the coupling of the cubic Redlich-Kwong-Soave equation of state with volume correction through a neural network. This new model was tested successfully, it makes it possible to benefit from the existing work of representation of phase equilibria (mixing rules and interaction coefficients) while improving calculation of the volumetric data.

  17. Volumetric changes of the graft after maxillary sinus floor augmentation with Bio-Oss and autogenous bone in different ratios

    DEFF Research Database (Denmark)

    Jensen, Thomas; Schou, Søren; Svendsen, Patricia Anne

    2012-01-01

    composition was selected at random and placed concomitant with implant placement. Computed tomographies of the maxillary sinuses were obtained preoperatively, immediately postoperatively, and at euthanasia after 12 weeks. The volumetric changes of the graft were estimated using the Cavalieri principle...

  18. Optimal planning strategy among various arc arrangements for prostate stereotactic body radiotherapy with volumetric modulated arc therapy technique

    Directory of Open Access Journals (Sweden)

    Kang Sang Won

    2017-03-01

    Full Text Available The aim of this study was to determine the optimal strategy among various arc arrangements in prostate plans of stereotactic body radiotherapy with volumetric modulated arc therapy (SBRT-VMAT.

  19. A 4 MV flattening filter-free beam: commissioning and application to conformal therapy and volumetric modulated arc therapy

    Energy Technology Data Exchange (ETDEWEB)

    Stevens, S W; Rosser, K E; Bedford, J L, E-mail: simon.stevens@nhs.net [Joint Department of Physics, Institute of Cancer Research and The Royal Marsden NHS Foundation Trust, Downs Road, Sutton, Surrey SM2 5PT (United Kingdom)

    2011-07-07

    Recent studies have indicated that radiotherapy treatments undertaken on a flattening filter-free (FFF) linear accelerator have a number of advantages over treatments undertaken on a conventional linear accelerator. In addition, 4 MV photon beams may give improved isodose coverage for some treatment volumes at air/tissue interfaces, compared to when utilizing the clinical standard of 6 MV photons. In order to investigate these benefits, FFF beams were established on an Elekta Beam Modulator linear accelerator for 4 MV photons. Commissioning beam data were obtained for open and wedged fields. The measured data were then imported into a treatment planning system and a beam model was commissioned. The beam model was optimized to improve dose calculations at shallow, clinically relevant depths. Following verification, the beam model was utilized in a treatment planning study, including volumetric modulated arc therapy, for a selection of lung, breast/chest wall and larynx patients. Increased dose rates of around 800 MU min{sup -1} were recorded for open fields (relative to 320 MU min{sup -1} for filtered open fields) and reduced head scatter was inferred from output factor measurements. Good agreement between planned and delivered dose was observed in verification of treatment plans. The planning study indicated that with a FFF beam, equivalent (and in some cases improved) isodose profiles could be achieved for small lung and larynx treatment volumes relative to 4 MV filtered treatments. Furthermore, FFF treatments with wedges could be replicated using open fields together with an 'effective wedge' technique and isocentre shift. Clinical feasibility of a FFF beam was therefore demonstrated, with beam modelling, treatment planning and verification being successfully accomplished.

  20. Volumetric Properties of the Mixture Trichloromethane CHCl3 + C4H10O Diethyl ether (VMSD1211, LB3412_V)

    Science.gov (United States)

    Cibulka, I.; Fontaine, J.-C.; Sosnkowska-Kehiaian, K.; Kehiaian, H. V.

    This document is part of Subvolume C 'Binary Liquid Systems of Nonelectrolytes III' of Volume 26 'Heats of Mixing, Vapor-Liquid Equilibrium, and Volumetric Properties of Mixtures and Solutions' of Landolt-Börnstein Group IV 'Physical Chemistry'. It contains the Chapter 'Volumetric Properties of the Mixture Trichloromethane CHCl3 + C4H10O Diethyl ether (VMSD1211, LB3412_V)' providing data from direct low-pressure dilatometric measurement of molar excess volume at variable mole fraction and constant temperature.

  1. Volumetric Properties of the Mixture Trichloromethane CHCl3 + C8H16 Cyclooctane (VMSD1211, LB3565_V)

    Science.gov (United States)

    Cibulka, I.; Fontaine, J.-C.; Sosnkowska-Kehiaian, K.; Kehiaian, H. V.

    This document is part of Subvolume B 'Binary Liquid Systems of Nonelectrolytes II' of Volume 26 'Heats of Mixing, Vapor-Liquid Equilibrium, and Volumetric Properties of Mixtures and Solutions' of Landolt-Börnstein Group IV 'Physical Chemistry'. It contains the Chapter 'Volumetric Properties of the Mixture Trichloromethane CHCl3 + C8H16 Cyclooctane (VMSD1211, LB3565_V)' providing data from direct low-pressure dilatometric measurement of molar excess volume at variable mole fraction and constant temperature.

  2. Volumetric Properties of the Mixture Trichloromethane CHCl3 + C5H10O Oxane (VMSD1212, LB3577_V)

    Science.gov (United States)

    Cibulka, I.; Fontaine, J.-C.; Sosnkowska-Kehiaian, K.; Kehiaian, H. V.

    This document is part of Subvolume C 'Binary Liquid Systems of Nonelectrolytes III' of Volume 26 'Heats of Mixing, Vapor-Liquid Equilibrium, and Volumetric Properties of Mixtures and Solutions' of Landolt-Börnstein Group IV 'Physical Chemistry'. It contains the Chapter 'Volumetric Properties of the Mixture Trichloromethane CHCl3 + C5H10O Oxane (VMSD1212, LB3577_V)' providing data by calculation of molar excess volume from low-pressure density measurements at variable mole fraction and constant temperature.

  3. Volumetric Properties of the Mixture Trichloromethane CHCl3 + C4H8O Oxolane (VMSD1212, LB3576_V)

    Science.gov (United States)

    Cibulka, I.; Fontaine, J.-C.; Sosnkowska-Kehiaian, K.; Kehiaian, H. V.

    This document is part of Subvolume C 'Binary Liquid Systems of Nonelectrolytes III' of Volume 26 'Heats of Mixing, Vapor-Liquid Equilibrium, and Volumetric Properties of Mixtures and Solutions' of Landolt-Börnstein Group IV 'Physical Chemistry'. It contains the Chapter 'Volumetric Properties of the Mixture Trichloromethane CHCl3 + C4H8O Oxolane (VMSD1212, LB3576_V)' providing data by calculation of molar excess volume from low-pressure density measurements at variable mole fraction and constant temperature.

  4. Volumetric Properties of the Mixture Trichloromethane CHCl3 + C6H14 Hexane (VMSD1211, LB4339_V)

    Science.gov (United States)

    Cibulka, I.; Fontaine, J.-C.; Sosnkowska-Kehiaian, K.; Kehiaian, H. V.

    This document is part of Subvolume B 'Binary Liquid Systems of Nonelectrolytes II' of Volume 26 'Heats of Mixing, Vapor-Liquid Equilibrium, and Volumetric Properties of Mixtures and Solutions' of Landolt-Börnstein Group IV 'Physical Chemistry'. It contains the Chapter 'Volumetric Properties of the Mixture Trichloromethane CHCl3 + C6H14 Hexane (VMSD1211, LB4339_V)' providing data from direct low-pressure dilatometric measurement of molar excess volume at variable mole fraction and constant temperature.

  5. Volumetric Properties of the Mixture Trichloromethane CHCl3 + C6H12 Cyclohexane (VMSD1211, LB3566_V)

    Science.gov (United States)

    Cibulka, I.; Fontaine, J.-C.; Sosnkowska-Kehiaian, K.; Kehiaian, H. V.

    This document is part of Subvolume A 'Binary Liquid Systems of Nonelectrolytes I' of Volume 26 'Heats of Mixing, Vapor-Liquid Equilibrium, and Volumetric Properties of Mixtures and Solutions' of Landolt-Börnstein Group IV 'Physical Chemistry'. It contains the Chapter 'Volumetric Properties of the Mixture Trichloromethane CHCl3 + C6H12 Cyclohexane (VMSD1211, LB3566_V)' providing data from direct low-pressure dilatometric measurement of molar excess volume at variable mole fraction and constant temperature.

  6. Volumetric Properties of the Mixture Trichloromethane CHCl3 + C6H7N Aniline (VMSD1211, LB4340_V)

    Science.gov (United States)

    Cibulka, I.; Fontaine, J.-C.; Sosnkowska-Kehiaian, K.; Kehiaian, H. V.

    This document is part of Subvolume C 'Binary Liquid Systems of Nonelectrolytes III' of Volume 26 'Heats of Mixing, Vapor-Liquid Equilibrium, and Volumetric Properties of Mixtures and Solutions' of Landolt-Börnstein Group IV 'Physical Chemistry'. It contains the Chapter 'Volumetric Properties of the Mixture Trichloromethane CHCl3 + C6H7N Aniline (VMSD1211, LB4340_V)' providing data from direct low-pressure dilatometric measurement of molar excess volume at variable mole fraction and constant temperature.

  7. Volumetric Properties of the Mixture Trichloromethane CHCl3 + C5H10 Cyclopentane (VMSD1211, LB3567_V)

    Science.gov (United States)

    Cibulka, I.; Fontaine, J.-C.; Sosnkowska-Kehiaian, K.; Kehiaian, H. V.

    This document is part of Subvolume A 'Binary Liquid Systems of Nonelectrolytes I' of Volume 26 'Heats of Mixing, Vapor-Liquid Equilibrium, and Volumetric Properties of Mixtures and Solutions' of Landolt-Börnstein Group IV 'Physical Chemistry'. It contains the Chapter 'Volumetric Properties of the Mixture Trichloromethane CHCl3 + C5H10 Cyclopentane (VMSD1211, LB3567_V)' providing data from direct low-pressure dilatometric measurement of molar excess volume at variable mole fraction and constant temperature.

  8. Volumetric Properties of the Mixture Trichloromethane CHCl3 + C2H6S 2-Thiapropane (VMSD1211, LB3233_V)

    Science.gov (United States)

    Cibulka, I.; Fontaine, J.-C.; Sosnkowska-Kehiaian, K.; Kehiaian, H. V.

    This document is part of Subvolume C 'Binary Liquid Systems of Nonelectrolytes III' of Volume 26 'Heats of Mixing, Vapor-Liquid Equilibrium, and Volumetric Properties of Mixtures and Solutions' of Landolt-Börnstein Group IV 'Physical Chemistry'. It contains the Chapter 'Volumetric Properties of the Mixture Trichloromethane CHCl3 + C2H6S 2-Thiapropane (VMSD1211, LB3233_V)' providing data from direct low-pressure dilatometric measurement of molar excess volume at variable mole fraction and constant temperature.

  9. Volumetric Properties of the Mixture Trichloromethane CHCl3 + C2H6OS Dimethyl sulfoxide (VMSD1211, LB3256_V)

    Science.gov (United States)

    Cibulka, I.; Fontaine, J.-C.; Sosnkowska-Kehiaian, K.; Kehiaian, H. V.

    This document is part of Subvolume C 'Binary Liquid Systems of Nonelectrolytes III' of Volume 26 'Heats of Mixing, Vapor-Liquid Equilibrium, and Volumetric Properties of Mixtures and Solutions' of Landolt-Börnstein Group IV 'Physical Chemistry'. It contains the Chapter 'Volumetric Properties of the Mixture Trichloromethane CHCl3 + C2H6OS Dimethyl sulfoxide (VMSD1211, LB3256_V)' providing data from direct low-pressure dilatometric measurement of molar excess volume at variable mole fraction and constant temperature.

  10. Volumetric Properties of the Mixture Trichloromethane CHCl3 + CH2Cl2 Dichloromethane (VMSD1212, LB4574_V)

    Science.gov (United States)

    Cibulka, I.; Fontaine, J.-C.; Sosnkowska-Kehiaian, K.; Kehiaian, H. V.

    This document is part of Subvolume A 'Binary Liquid Systems of Nonelectrolytes I' of Volume 26 'Heats of Mixing, Vapor-Liquid Equilibrium, and Volumetric Properties of Mixtures and Solutions' of Landolt-Börnstein Group IV 'Physical Chemistry'. It contains the Chapter 'Volumetric Properties of the Mixture Trichloromethane CHCl3 + CH2Cl2 Dichloromethane (VMSD1212, LB4574_V)' providing data by calculation of molar excess volume from low-pressure density measurements at variable mole fraction and constant temperature.

  11. Volumetric Properties of the Mixture Trichloromethane CHCl3 + C6H6 Benzene (VMSD1212, LB3207_V)

    Science.gov (United States)

    Cibulka, I.; Fontaine, J.-C.; Sosnkowska-Kehiaian, K.; Kehiaian, H. V.

    This document is part of Subvolume A 'Binary Liquid Systems of Nonelectrolytes I' of Volume 26 'Heats of Mixing, Vapor-Liquid Equilibrium, and Volumetric Properties of Mixtures and Solutions' of Landolt-Börnstein Group IV 'Physical Chemistry'. It contains the Chapter 'Volumetric Properties of the Mixture Trichloromethane CHCl3 + C6H6 Benzene (VMSD1212, LB3207_V)' providing data by calculation of molar excess volume from low-pressure density measurements at variable mole fraction and constant temperature.

  12. Volumetric Properties of the Mixture Trichloromethane CHCl3 + C2H3N Ethanenitrile (VMSD1212, LB4352_V)

    Science.gov (United States)

    Cibulka, I.; Fontaine, J.-C.; Sosnkowska-Kehiaian, K.; Kehiaian, H. V.

    This document is part of Subvolume C 'Binary Liquid Systems of Nonelectrolytes III' of Volume 26 'Heats of Mixing, Vapor-Liquid Equilibrium, and Volumetric Properties of Mixtures and Solutions' of Landolt-Börnstein Group IV 'Physical Chemistry'. It contains the Chapter 'Volumetric Properties of the Mixture Trichloromethane CHCl3 + C2H3N Ethanenitrile (VMSD1212, LB4352_V)' providing data by calculation of molar excess volume from low-pressure density measurements at variable mole fraction and constant temperature.

  13. Volumetric Properties of the Mixture Trichloromethane CHCl3 + C4H10S 3-Thiapentane (VMSD1211, LB3237_V)

    Science.gov (United States)

    Cibulka, I.; Fontaine, J.-C.; Sosnkowska-Kehiaian, K.; Kehiaian, H. V.

    This document is part of Subvolume C 'Binary Liquid Systems of Nonelectrolytes III' of Volume 26 'Heats of Mixing, Vapor-Liquid Equilibrium, and Volumetric Properties of Mixtures and Solutions' of Landolt-Börnstein Group IV 'Physical Chemistry'. It contains the Chapter 'Volumetric Properties of the Mixture Trichloromethane CHCl3 + C4H10S 3-Thiapentane (VMSD1211, LB3237_V)' providing data from direct low-pressure dilatometric measurement of molar excess volume at variable mole fraction and constant temperature.

  14. An Improved Frequency Domain Technique for Determining Soil Water Content

    Institute of Scientific and Technical Information of China (English)

    SUN Yu-Rui; MA Dao-Kun; LIN Jian-Hui; P. SCHULZE LAMMERS; L. DAMEROW

    2005-01-01

    For many years a soil water content sensor with low cost, reliability and sufficient accuracy has been desirable. Thus,an improved measurement method based on the frequency domain (FD) principle for determining soil water content was considered. Unlike other measurement principles, a new measurable index, η, which was independent of the output impedance and the amplitude of the oscillator while relying on the electrical impedance of a multi-pin probe, was proposed. Moreover, a model for processing the impedance of the multi-pin soil probe was developed, and several important electrical parameters for establishing their operating ranges applicable to this probe were evaluated. In order to confirm the theoretical analysis, an experiment was conducted with a 4-pin probe. Using the developed model, the relationship between the proposed indexηand soil volumetric water content was shown to be linear (R2 = 0.9921). Thus, as the measurable index, ηseemed satisfactory.

  15. 1-D diffusion based solidification model with volumetric expansion and shrinkage effect: A semi-analytical approach

    Science.gov (United States)

    Monde, Aniket D.; Chakraborty, Prodyut R.

    2017-10-01

    Volumetric expansion and shrinkage due to different densities of solid and liquid phases are common phenomena during solidification process. Simple analytical models addressing effect of volumetric expansion/shrinkage during solidification are rarely found. The few existing 1-D solidification models are valid only for semi-infinite domain with limitations of their application for finite domain size. The focus of the present work is to develop a 1-D semi-analytical solidification model addressing effects of volumetric expansion/shrinkage in a finite domain. The proposed semi-analytical scheme involves finding simultaneous solution of transient 1-D heat diffusion equations at solid and liquid domain coupled at the interface by Stefan condition. The change of the total domain length during solidification due to volumetric expansion/shrinkage is addressed by using mass conservation. For validation of the proposed model, solidification of water in a finite domain is studied without considering volumetric expansion/shrinkage effect and results are compared with those obtained from existing enthalpy updating based numerical model. After validation, case studies pertaining to volumetric expansion and shrinkage are performed considering solidification of water and paraffin respectively and physically consistent results are obtained. The study is relevant for understanding unidirectional crystal growth under the effect of controlled boundary condition.

  16. Indoor Air Quality Management Program.

    Science.gov (United States)

    Anne Arundel County Public Schools, Annapolis, MD.

    In an effort to provide Indoor Air Quality (IAQ) management guidance, Anne Arundel County Public Schools was selected by the Maryland State Department of Education to develop a program that could be used by other school systems. A major goal was to produce a handbook that was "user friendly." Hence, its contents are a mix of history,…

  17. Air surveillance

    Energy Technology Data Exchange (ETDEWEB)

    Patton, G.W.

    1995-06-01

    This section of the 1994 Hanford Site Environmental Report summarizes the air surveillance and monitoring programs currently in operation at that Hanford Site. Atmospheric releases of pollutants from Hanford to the surrounding region are a potential source of human exposure. For that reason, both radioactive and nonradioactive materials in air are monitored at a number of locations. The influence of Hanford emissions on local radionuclide concentrations was evaluated by comparing concentrations measured at distant locations within the region to concentrations measured at the Site perimeter. This section discusses sample collection, analytical methods, and the results of the Hanford air surveillance program. A complete listing of all analytical results summarized in this section is reported separately by Bisping (1995).

  18. Influência da temperatura e velocidade do ar na secagem de manjericão (Ocimum basilicum L. com relação aos teores de óleos essenciais e de linalol Influence of drying temperature and air velocity related to essential oil and linalol contents of the basil (Ocimum basilicum L.

    Directory of Open Access Journals (Sweden)

    Rilvaynia Dantas Soares

    2007-08-01

    Full Text Available Neste trabalho, objetivou-se estudar a influência de quatro temperaturas de ar de secagem (40, 50, 60 e 70 ºC, em camada fina, e duas velocidades do ar (0,9 e 1,9 m/s sobre o teor de linalol do manjericão (Ocimum basilicum L. Utilizou-se um secador de bandejas especialmente desenvolvido, no laboratório de Secagem da UESB, Campus de Itapetinga-BA. Foram feitas quatro repetições, com 100 g de folhas frescas em cada uma das cinco bandejas da câmara de secagem. Na extração do óleo essencial, utilizou-se um sistema de destilação por arraste a vapor e a análise do óleo essencial foi realizada em um cromatógrafo conectado a um e espectrômetro de massa (CG-MS. Os maiores rendimentos de óleos essenciais de manjericão foram obtidos no processo de secagem com temperatura do ar igual a 40 ºC e 1,9 m/s de velocidade do ar. Os maiores rendimentos de linalol foram obtidos com temperatura do ar de secagem na faixa de 50 a 60 ºC e 1,9 m/s de velocidade do ar (2,23 e 2,47 ppm, respectivamente. Por análise de regressão, estimou-se que a temperatura de 54,4 ºC e a velocidade de 1,9 m/s forneceriam o maior rendimento de linalol. Concluiu-se que a composição química do óleo essencial do manjericão é afetada tanto pela temperatura como pela velocidade do ar de secagem.This work aimed to study the influence of four thin layer drying temperatures (40, 50, 60 and 70 ºC and two air velocities (0.9 and 1.9 m/s in the content of linalol of the Basil (Ocimum basilicum L.. It was used a tray dryer specially built for this experiment in the drying laboratory of the UESB at the "Campus de Itapetinga-Ba". There were made four repetitions with 100 g of fresh leaves in each one of the five trays in the dry chamber In the extraction of the essential oil, a vapor hauling system was used and the oil analysis was made in a gas chromatographer that was connected to a mass spectrometer (CG-MS. The greatest extracted profits of basil's essential oil were

  19. Royal Danish Air Force. Air Operations Doctrine

    DEFF Research Database (Denmark)

    Nørby, Søren

    This brief examines the development of the first Danish Air Force Air Operations Doctrine, which was officially commissioned in October 1997 and remained in effect until 2010. The development of a Danish air power doctrine was heavily influenced by the work of Colonel John Warden (USAF), both...... through his book ”The Air Campaign” and his subsequent planning of the air campaign against Iraq in 1990-1991. Warden’s ideas came to Denmark and the Danish Air Force by way of Danish Air Force students attending the United States Air Force Air University in Alabama, USA. Back in Denmark, graduates from...... the Air University inspired a small number of passionate airmen, who then wrote the Danish Air Operations Doctrine. The process was supported by the Air Force Tactical Command, which found that the work dovetailed perfectly with the transformation process that the Danish Air Force was in the midst...

  20. Area and volumetric density estimation in processed full-field digital mammograms for risk assessment of breast cancer.

    Directory of Open Access Journals (Sweden)

    Abbas Cheddad

    Full Text Available INTRODUCTION: Mammographic density, the white radiolucent part of a mammogram, is a marker of breast cancer risk and mammographic sensitivity. There are several means of measuring mammographic density, among which are area-based and volumetric-based approaches. Current volumetric methods use only unprocessed, raw mammograms, which is a problematic restriction since such raw mammograms are normally not stored. We describe fully automated methods for measuring both area and volumetric mammographic density from processed images. METHODS: The data set used in this study comprises raw and processed images of the same view from 1462 women. We developed two algorithms for processed images, an automated area-based approach (CASAM-Area and a volumetric-based approach (CASAM-Vol. The latter method was based on training a random forest prediction model with image statistical features as predictors, against a volumetric measure, Volpara, for corresponding raw images. We contrast the three methods, CASAM-Area, CASAM-Vol and Volpara directly and in terms of association with breast cancer risk and a known genetic variant for mammographic density and breast cancer, rs10995190 in the gene ZNF365. Associations with breast cancer risk were evaluated using images from 47 breast cancer cases and 1011 control subjects. The genetic association analysis was based on 1011 control subjects. RESULTS: All three measures of mammographic density were associated with breast cancer risk and rs10995190 (p0.10 for risk, p>0.03 for rs10995190. CONCLUSIONS: Our results show that it is possible to obtain reliable automated measures of volumetric and area mammographic density from processed digital images. Area and volumetric measures of density on processed digital images performed similar in terms of risk and genetic association.

  1. Characterization of three dimensional volumetric strain distribution during passive tension of the human tibialis anterior using Cine Phase Contrast MRI.

    Science.gov (United States)

    Jensen, Elisabeth R; Morrow, Duane A; Felmlee, Joel P; Murthy, Naveen S; Kaufman, Kenton R

    2016-10-03

    Intramuscular pressure correlates strongly with muscle tension and is a promising tool for quantifying individual muscle force. However, clinical application is impeded by measurement variability that is not fully understood. Previous studies point to regional differences in IMP, specifically increasing pressure with muscle depth. Based on conservation of mass, intramuscular pressure and volumetric strain distributions may be inversely related. Therefore, we hypothesized volumetric strain would decrease with muscle depth. To test this we quantified 3D volumetric strain in the tibialis anterior of 12 healthy subjects using Cine Phase Contrast Magnetic Resonance Imaging. Cine Phase Contrast data were collected while a custom apparatus rotated the subjects' ankle continuously between neutral and plantarflexion. A T2-weighted image stack was used to define the resting tibials anterior position. Custom and commercial post-processing software were used to quantify the volumetric strain distribution. To characterize regional strain changes, the muscle was divided into superior-inferior sections and either medial-lateral or anterior-posterior slices. Mean volumetric strain was compared across the sections and slices. As hypothesized, volumetric strain demonstrated regional differences with a decreasing trend from the anterior (superficial) to the posterior (deep) muscle regions. Statistical tests showed significant main effects and interactions of superior-inferior and anterior-posterior position as well as superior-inferior and medial-lateral position on regional strain. These data support our hypothesis and imply a potential relationship between regional volumetric strain and intramuscular pressure. This finding may advance our understanding of intramuscular pressure variability sources and lead to more reliable measurement solutions in the future. Copyright © 2016 Elsevier Ltd. All rights reserved.

  2. Volumetric intake flow measurements of an IC engine using magnetic resonance velocimetry

    Science.gov (United States)

    Freudenhammer, Daniel; Baum, Elias; Peterson, Brian; Böhm, Benjamin; Jung, Bernd; Grundmann, Sven

    2014-05-01

    Magnetic resonance velocimetry (MRV) measurements are performed in a 1:1 scale model of a single-cylinder optical engine to investigate the volumetric flow within the intake and cylinder geometry during flow induction. The model is a steady flow water analogue of the optical IC-engine with a fixed valve lift of mm to simulate the induction flow at crank-angle bTDC. This setup resembles a steady flow engine test bench configuration. MRV measurements are validated with phase-averaged particle image velocimetry (PIV) measurements performed within the symmetry plane of the optical engine. Differences in experimental operating parameters between MRV and PIV measurements are well addressed. Comparison of MRV and PIV measurements is demonstrated using normalized mean velocity component profiles and showed excellent agreement in the upper portion of the cylinder chamber (i.e., mm). MRV measurements are further used to analyze the ensemble average volumetric flow within the 3D engine domain. Measurements are used to describe the 3D overflow and underflow behavior as the annular flow enters the cylinder chamber. Flow features such as the annular jet-like flows extending into the cylinder, their influence on large-scale in-cylinder flow motion, as well as flow recirculation zones are identified in 3D space. Inlet flow velocities are analyzed around the entire valve curtain perimeter to quantify percent mass flow rate entering the cylinder. Recirculation zones associated with the underflow are shown to reduce local mass flow rates up to 50 %. Recirculation zones are further analyzed in 3D space within the intake manifold and cylinder chamber. It is suggested that such recirculation zones can have large implications on cylinder charge filling and variations of the in-cylinder flow pattern. MRV is revealed to be an important diagnostic tool used to understand the volumetric induction flow within engine geometries and is potentially suited to evaluate flow changes due to intake

  3. Using on-site liver 3-D reconstruction and volumetric calculations in split liver transplantation

    Institute of Scientific and Technical Information of China (English)

    Trevor W Reichman; Brittan Y Fiorello; Ian Carmody; Humberto Bohorquez; Ari Cohen; John Seal; David Bruce; George E Loss

    2016-01-01

    BACKGROUND: Split liver transplantation increases the number of grafts available for transplantation. Pre-recovery assessment of liver graft volume is essential for selecting suit-able recipients. The purpose of this study was to determine the ability and feasibility of constructing a 3-D model to aid in surgical planning and to predict graft weight prior to anin situ division of the donor liver. METHODS: Over 11 months, 3-D volumetric reconstruction of 4 deceased donors was performed using Pathifnder Scout© liver volumetric software. Demographic, laboratory, operative, perioperative and survival data for these patients along with donor demographic data were collected prospectively and analyzed retrospectively. RESULTS: The average predicted weight of the grafts from the adult donors obtained from anin situ split procedure were 1130 g (930-1458 g) for the extended right lobe donors and 312 g (222-396 g) for left lateral segment grafts. Actual adult graft weight was 92% of the predicted weight for both the ex-tended right grafts and the left lateral segment grafts. The pre-dicted and actual graft weights for the pediatric donors were 176 g and 210 g for the left lateral segment grafts and 308 g and 280 g for the extended right lobe grafts, respectively. All grafts were transplanted except for the right lobe from the pediatric donors due to the small graft weight. CONCLUSIONS: On-site volumetric assessment of donors provides useful information for the planning of anin situ split and for selection of recipients. This information may expand the donor pool to recipients previously felt to be unsuitable due to donor and/or recipient weight.

  4. Disorder-specific volumetric brain difference in adolescent major depressive disorder and bipolar depression.

    Science.gov (United States)

    MacMaster, Frank P; Carrey, Normand; Langevin, Lisa Marie; Jaworska, Natalia; Crawford, Susan

    2014-03-01

    Structural abnormalities in frontal, limbic and subcortical regions have been noted in adults with both major depressive disorder (MDD) and bipolar disorder (BD). In the current study, we examined regional brain morphology in youth with MDD and BD as compared to controls. Regional brain volumes were measured in 32 MDD subjects (15.7 ± 2.1 years), 14 BD subjects (16.0 ± 2.4 years) and 22 healthy controls (16.0 ± 2.8 years) using magnetic resonance imaging (MRI). Regions of interest included the hippocampus, dorsolateral prefrontal cortex (DLPFC), anterior cingulate cortex (ACC), caudate, putamen and thalamus. Volumetric differences between groups were significant (F26,80 = 1.80, p = 0.02). Post-hoc analyses indicated that individuals with MDD showed reduced left hippocampus volumes (p = 0.048) as well as right ACC white and gray matter volumes (p = 0.003; p = 0.01) compared to controls. BD participants also displayed reduced left hippocampal and right/left putamen volumes compared to controls (p < 0.001; p = 0.015; p = 0.046 respectively). Interestingly, right and left ACC white matter volumes were smaller in MDD than in BD participants (p = 0.019; p = 0.045 respectively). No volumetric group differences were observed for the DLPFC and thalamus. Discriminant analysis was able to correctly classify 81.0 % of subjects as having BD or as MDD based on imaging data. Confirmation and extension of our findings requires larger sample sizes. Our findings provide new evidence of distinct, specific regional brain volumetric differences between MDD and BD that may be used to distinguish the two disorders.

  5. Evaluation of feature-based 3-d registration of probabilistic volumetric scenes

    Science.gov (United States)

    Restrepo, Maria I.; Ulusoy, Ali O.; Mundy, Joseph L.

    2014-12-01

    Automatic estimation of the world surfaces from aerial images has seen much attention and progress in recent years. Among current modeling technologies, probabilistic volumetric models (PVMs) have evolved as an alternative representation that can learn geometry and appearance in a dense and probabilistic manner. Recent progress, in terms of storage and speed, achieved in the area of volumetric modeling, opens the opportunity to develop new frameworks that make use of the PVM to pursue the ultimate goal of creating an entire map of the earth, where one can reason about the semantics and dynamics of the 3-d world. Aligning 3-d models collected at different time-instances constitutes an important step for successful fusion of large spatio-temporal information. This paper evaluates how effectively probabilistic volumetric models can be aligned using robust feature-matching techniques, while considering different scenarios that reflect the kind of variability observed across aerial video collections from different time instances. More precisely, this work investigates variability in terms of discretization, resolution and sampling density, errors in the camera orientation, and changes in illumination and geographic characteristics. All results are given for large-scale, outdoor sites. In order to facilitate the comparison of the registration performance of PVMs to that of other 3-d reconstruction techniques, the registration pipeline is also carried out using Patch-based Multi-View Stereo (PMVS) algorithm. Registration performance is similar for scenes that have favorable geometry and the appearance characteristics necessary for high quality reconstruction. In scenes containing trees, such as a park, or many buildings, such as a city center, registration performance is significantly more accurate when using the PVM.

  6. A Multicenter Study of Volumetric Computed Tomography for Staging Malignant Pleural Mesothelioma.

    Science.gov (United States)

    Rusch, Valerie W; Gill, Ritu; Mitchell, Alan; Naidich, David; Rice, David C; Pass, Harvey I; Kindler, Hedy L; De Perrot, Marc; Friedberg, Joseph

    2016-10-01

    Standard imaging modalities are inaccurate in staging malignant pleural mesothelioma (MPM). Single-institution studies suggest that volumetric computed tomography (CT) is more accurate but labor intensive. We established a multicenter network to test interobserver variability, accuracy (relative to pathologic stage), and the prognostic significance of semiautomated volumetric CT. Six institutions electronically submitted to an established multicenter database clinical and pathologic data for patients with MPM who had operations. Institutional radiologists reviewed preoperative CT scans for quality and then submitted by electronic network (AG Mednet, www.agmednet.com) to the biostatistical center. Two reference radiologists blinded to clinical data performed semiautomated tumor volume calculations using Vitrea Enterprise 6.0 software (Vital Images, Minnetonka, MN) and then submitted readings to the biostatistical center. Study end points included feasibility of the network, interobserver variability for volumetric CT, correlation of tumor volume to pTN stages, and overall survival (OS). Of 164 patients, the CT scans for 129 were analyzable and read by reference radiologists. Most tumors were less than 500 cm(3). A small bias was observed between readers because one provided consistently larger measurements than the other (mean difference, 47.9; p = .0027), but for 80%, the absolute difference was 200 cm(3) or less. Spearman correlation between readers was 0.822. Volume correlated with pTN stages and OS, best defined by three groups with average volumes of 91.2, 245.3, and 511.3 cm(3) associated with median OS of 37, 18, and 8 months, respectively. For the first time, a multicenter network was established and initial correlations of tumor volume with pTN stages and OS are shown. A larger multicenter international study is planned to confirm the results and refine correlations. Copyright © 2016 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights

  7. Somatic mutations associated with MRI-derived volumetric features in glioblastoma

    Energy Technology Data Exchange (ETDEWEB)

    Gutman, David A.; Dunn, William D. [Emory University School of Medicine, Departments of Neurology, Atlanta, GA (United States); Emory University School of Medicine, Biomedical Informatics, Atlanta, GA (United States); Grossmann, Patrick; Alexander, Brian M. [Harvard Medical School, Department of Radiation Oncology, Dana-Farber Cancer Institute, Brigham and Women' s Hospital, Boston, MA (United States); Cooper, Lee A.D. [Emory University School of Medicine, Biomedical Informatics, Atlanta, GA (United States); Georgia Institute of Technology, Department of Biomedical Engineering, Atlanta, GA (United States); Holder, Chad A. [Emory University School of Medicine, Radiology and Imaging Sciences, Atlanta, GA (United States); Ligon, Keith L. [Brigham and Women' s Hospital, Harvard Medical School, Pathology, Dana-Farber Cancer Institute, Boston, MA (United States); Aerts, Hugo J.W.L. [Harvard Medical School, Department of Radiation Oncology, Dana-Farber Cancer Institute, Brigham and Women' s Hospital, Boston, MA (United States); Brigham and Women' s Hospital, Harvard Medical School, Radiology, Dana-Farber Cancer Institute, Boston, MA (United States)

    2015-12-15

    MR imaging can noninvasively visualize tumor phenotype characteristics at the macroscopic level. Here, we investigated whether somatic mutations are associated with and can be predicted by MRI-derived tumor imaging features of glioblastoma (GBM). Seventy-six GBM patients were identified from The Cancer Imaging Archive for whom preoperative T1-contrast (T1C) and T2-FLAIR MR images were available. For each tumor, a set of volumetric imaging features and their ratios were measured, including necrosis, contrast enhancing, and edema volumes. Imaging genomics analysis assessed the association of these features with mutation status of nine genes frequently altered in adult GBM. Finally, area under the curve (AUC) analysis was conducted to evaluate the predictive performance of imaging features for mutational status. Our results demonstrate that MR imaging features are strongly associated with mutation status. For example, TP53-mutated tumors had significantly smaller contrast enhancing and necrosis volumes (p = 0.012 and 0.017, respectively) and RB1-mutated tumors had significantly smaller edema volumes (p = 0.015) compared to wild-type tumors. MRI volumetric features were also found to significantly predict mutational status. For example, AUC analysis results indicated that TP53, RB1, NF1, EGFR, and PDGFRA mutations could each be significantly predicted by at least one imaging feature. MRI-derived volumetric features are significantly associated with and predictive of several cancer-relevant, drug-targetable DNA mutations in glioblastoma. These results may shed insight into unique growth characteristics of individual tumors at the macroscopic level resulting from molecular events as well as increase the use of noninvasive imaging in personalized medicine. (orig.)

  8. Heritability of volumetric brain changes and height in children entering puberty.

    Science.gov (United States)

    van Soelen, Inge L C; Brouwer, Rachel M; van Baal, G Caroline M; Schnack, Hugo G; Peper, Jiska S; Chen, Lei; Kahn, René S; Boomsma, Dorret I; Hulshoff Pol, Hilleke E

    2013-03-01

    The human brain undergoes structural changes in children entering puberty, while simultaneously children increase in height. It is not known if brain changes are under genetic control, and whether they are related to genetic factors influencing the amount of overall increase in height. Twins underwent magnetic resonance imaging brain scans at age 9 (N = 190) and 12 (N = 125). High heritability estimates were found at both ages for height and brain volumes (49-96%), and high genetic correlation between ages were observed (r(g) > 0.89). With increasing age, whole brain (+1.1%), cerebellum (+4.2%), cerebral white matter (+5.1%), and lateral ventricle (+9.4%) volumes increased, and third ventricle (-4.0%) and cerebral gray matter (-1.6%) volumes decreased. Children increased on average 13.8 cm in height (9.9%). Genetic influences on individual difference in volumetric brain and height changes were estimated, both within and across traits. The same genetic factors influenced both cerebral (20% heritable) and cerebellar volumetric changes (45%). Thus, the extent to which changes in cerebral and cerebellar volumes are heritable in children entering puberty are due to the same genes that influence change in both structures. The increase in height was heritable (73%), and not associated with cerebral volumetric change, but positively associated with cerebellar volume change (r(p) = 0.24). This association was explained by a genetic correlation (r(g) = 0.48) between height and cerebellar change. Brain and body each expand at their own pace and through separate genetic pathways. There are distinct genetic processes acting on structural brain development, which cannot be explained by genetic increase in height.

  9. The importance of volumetric canopy morphology when modelling drag around riparian vegetation

    Science.gov (United States)

    Boothroyd, Richard; Hardy, Richard; Warburton, Jeff; Marjoribanks, Timothy

    2017-04-01

    Riparian vegetation has a significant impact on the hydraulic functioning of river systems. The bulk of past work concerned with modelling the influence of vegetation on flow has considered vegetation to be morphologically simple, and has generally neglected the complexity and porosity of natural plants, defined herein as the volumetric canopy morphology. However, the volumetric canopy morphology can influence the mean and turbulent properties of the flow, producing spatially heterogeneous downstream velocity fields. By explicitly accounting for this in a computational fluid dynamics (CFD) model, and representing the plant as a porous blockage, complex flow structures and drag can be modelled. For a riparian species, Hebe odora, good agreement with flume measurements are found. Plant shear layer turbulence is shown to be dominated by Kelvin-Helmholtz and Görtler-type vortices, generated through shear instability. Porous representations of the plants, that allow for flow to pass through the plant canopy interior, are compared against fully impermeable plant representations. Penetration of fluid through the canopy in the porous case resembles 'bleed-flow', and this results in a plant wake region that significantly differs from the impermeable case, which is characteristic of wake flow around a traditional bluff body. These results demonstrate the significant effect that the volumetric canopy morphology and porosity of natural plants has on the three-dimensional flow and in-stream drag, and enables a re-evaluation of vegetative flow resistance. The modelled results allow a species dependent Manning's n to be calculated, and this presents an opportunity to move away from the conventional methods of representing vegetation in hydraulic models, in favour of a more physically determined approach. Given the importance of vegetation in river corridor management, and the increasing application of UAV imagery to map riparian vegetation, the numerical scheme developed here

  10. MTF analysis of a prototype table-top inverse-geometry volumetric CT system

    Science.gov (United States)

    Schmidt, Taly G.; Bennett, N. Robert; Mazin, Samuel R.; Star-Lack, Josh; Solomon, Edward G.; Pelc, Norbert J.

    2005-04-01

    This work investigates the modulation transfer function (MTF) of a prototype table-top inverse-geometry volumetric CT (IGCT) system. The IGCT system has been proposed to acquire sufficient volumetric data in one circular rotation using a large-area scanned source and a narrower array of fast detectors. The source and detector arrays have the same axial, or slice, extent, thus providing sufficient volumetric coverage. A prototype system has been built using a NexRay Scanning-Beam Digital X-ray system (NexRay, Inc., Los Gatos, CA) with the C-arm gantry in the horizontal position and a stage placed between the source and detector to rotate the scanned object. The resulting system has a 16-cm in-plane field of view (FOV) and 5-cm axial FOV. Two phantoms were constructed for measuring the MTF. A 76 micron tungsten wire placed axially in a plastic frame was used to measure the in-plane MTF, and the same wire slanted at 45 degrees was used to test the isotropy of the MTF. The data were calibrated for flat-field intensity and geometric misalignment and reconstructed using a modified 3D PET algorithm. For both phantoms, slices perpendicular to the wires were reconstructed. Simulations which model the IGCT system were used to verify the MTF measurement, along with analytical predictions. The measured MTF curve was similar in shape to the predicted curve with a 10% point at 20 lp/cm compared to a predicted 18 lp/cm. Future work will also study the uniformity of the MTF across the FOV and further characterize the IGCT system.

  11. Conductive two-dimensional titanium carbide `clay' with high volumetric capacitance

    Science.gov (United States)

    Ghidiu, Michael; Lukatskaya, Maria R.; Zhao, Meng-Qiang; Gogotsi, Yury; Barsoum, Michel W.

    2014-12-01

    Safe and powerful energy storage devices are becoming increasingly important. Charging times of seconds to minutes, with power densities exceeding those of batteries, can in principle be provided by electrochemical capacitors--in particular, pseudocapacitors. Recent research has focused mainly on improving the gravimetric performance of the electrodes of such systems, but for portable electronics and vehicles volume is at a premium. The best volumetric capacitances of carbon-based electrodes are around 300 farads per cubic centimetre; hydrated ruthenium oxide can reach capacitances of 1,000 to 1,500 farads per cubic centimetre with great cyclability, but only in thin films. Recently, electrodes made of two-dimensional titanium carbide (Ti3C2, a member of the `MXene' family), produced by etching aluminium from titanium aluminium carbide (Ti3AlC2, a `MAX' phase) in concentrated hydrofluoric acid, have been shown to have volumetric capacitances of over 300 farads per cubic centimetre. Here we report a method of producing this material using a solution of lithium fluoride and hydrochloric acid. The resulting hydrophilic material swells in volume when hydrated, and can be shaped like clay and dried into a highly conductive solid or rolled into films tens of micrometres thick. Additive-free films of this titanium carbide `clay' have volumetric capacitances of up to 900 farads per cubic centimetre, with excellent cyclability and rate performances. This capacitance is almost twice that of our previous report, and our synthetic method also offers a much faster route to film production as well as the avoidance of handling hazardous concentrated hydrofluoric acid.

  12. Conductive two-dimensional titanium carbide 'clay' with high volumetric capacitance.

    Science.gov (United States)

    Ghidiu, Michael; Lukatskaya, Maria R; Zhao, Meng-Qiang; Gogotsi, Yury; Barsoum, Michel W

    2014-12-04

    Safe and powerful energy storage devices are becoming increasingly important. Charging times of seconds to minutes, with power densities exceeding those of batteries, can in principle be provided by electrochemical capacitors--in particular, pseudocapacitors. Recent research has focused mainly on improving the gravimetric performance of the electrodes of such systems, but for portable electronics and vehicles volume is at a premium. The best volumetric capacitances of carbon-based electrodes are around 300 farads per cubic centimetre; hydrated ruthenium oxide can reach capacitances of 1,000 to 1,500 farads per cubic centimetre with great cyclability, but only in thin films. Recently, electrodes made of two-dimensional titanium carbide (Ti3C2, a member of the 'MXene' family), produced by etching aluminium from titanium aluminium carbide (Ti3AlC2, a 'MAX' phase) in concentrated hydrofluoric acid, have been shown to have volumetric capacitances of over 300 farads per cubic centimetre. Here we report a method of producing this material using a solution of lithium fluoride and hydrochloric acid. The resulting hydrophilic material swells in volume when hydrated, and can be shaped like clay and dried into a highly conductive solid or rolled into films tens of micrometres thick. Additive-free films of this titanium carbide 'clay' have volumetric capacitances of up to 900 farads per cubic centimetre, with excellent cyclability and rate performances. This capacitance is almost twice that of our previous report, and our synthetic method also offers a much faster route to film production as well as the avoidance of handling hazardous concentrated hydrofluoric acid.

  13. Cerebrospinal fluid volumetric MRI mapping as a simple measurement for evaluating brain atrophy.

    Science.gov (United States)

    De Vis, J B; Zwanenburg, J J; van der Kleij, L A; Spijkerman, J M; Biessels, G J; Hendrikse, J; Petersen, E T

    2016-05-01

    To assess whether volumetric cerebrospinal fluid (CSF) MRI can be used as a surrogate for brain atrophy assessment and to evaluate how the T2 of the CSF relates to brain atrophy. Twenty-eight subjects [mean age 64 (sd 2) years] were included; T1-weighted and CSF MRI were performed. The first echo data of the CSF MRI sequence was used to obtain intracranial volume, CSF partial volume was measured voxel-wise to obtain CSF volume (VCSF) and the T2 of CSF (T2,CSF) was calculated. The correlation between VCSF/T2,CSF and brain atrophy scores [global cortical atrophy (GCA) and medial temporal lobe atrophy (MTA)] was evaluated. Relative total, peripheral subarachnoidal, and ventricular VCSF increased significantly with increased scores on the GCA and MTA (R = 0.83, 0.78 and 0.78 and R = 0.72, 0.62 and 0.86). Total, peripheral subarachnoidal, and ventricular T2 of the CSF increased significantly with higher scores on the GCA and MTA (R = 0.72, 0.70 and 0.49 and R = 0.60, 0.57 and 0.41). A fast, fully automated CSF MRI volumetric sequence is an alternative for qualitative atrophy scales. The T2 of the CSF is related to brain atrophy and could thus be a marker of neurodegenerative disease. • A 1:11 min CSF MRI volumetric sequence can evaluate brain atrophy. • CSF MRI provides accurate atrophy assessment without partial volume effects. • CSF MRI data can be processed quickly without user interaction. • The measured T 2 of the CSF is related to brain atrophy.

  14. Parallel implementation of 3D FFT with volumetric decomposition schemes for efficient molecular dynamics simulations

    Science.gov (United States)

    Jung, Jaewoon; Kobayashi, Chigusa; Imamura, Toshiyuki; Sugita, Yuji

    2016-03-01

    Three-dimensional Fast Fourier Transform (3D FFT) plays an important role in a wide variety of computer simulations and data analyses, including molecular dynamics (MD) simulations. In this study, we develop hybrid (MPI+OpenMP) parallelization schemes of 3D FFT based on two new volumetric decompositions, mainly for the particle mesh Ewald (PME) calculation in MD simulations. In one scheme, (1d_Alltoall), five all-to-all communications in one dimension are carried out, and in the other, (2d_Alltoall), one two-dimensional all-to-all communication is combined with two all-to-all communications in one dimension. 2d_Alltoall is similar to the conventional volumetric decomposition scheme. We performed benchmark tests of 3D FFT for the systems with different grid sizes using a large number of processors on the K computer in RIKEN AICS. The two schemes show comparable performances, and are better than existing 3D FFTs. The performances of 1d_Alltoall and 2d_Alltoall depend on the supercomputer network system and number of processors in each dimension. There is enough leeway for users to optimize performance for their conditions. In the PME method, short-range real-space interactions as well as long-range reciprocal-space interactions are calculated. Our volumetric decomposition schemes are particularly useful when used in conjunction with the recently developed midpoint cell method for short-range interactions, due to the same decompositions of real and reciprocal spaces. The 1d_Alltoall scheme of 3D FFT takes 4.7 ms to simulate one MD cycle for a virus system containing more than 1 million atoms using 32,768 cores on the K computer.

  15. Air void structure and frost resistance

    DEFF Research Database (Denmark)

    Hasholt, Marianne Tange

    2014-01-01

    is proportional to the product of total air content and specific surface. In all 4 cases, the conclusion is concurrent that the parameter of total surface area of air voids performs equally well or better than the spacing factor when linking air void characteristics to frost resistance (salt frost scaling...... will take place in the air void, being feed from the capillary, but without pressure build-up in the capillary. If the capillary is not connected to an air void, ice formation will take place in the capillary pore, where it can generate substantial pressure. Like this, frost resistance depends......This article compiles results from 4 independent laboratory studies. In each study, the same type of concrete is tested at least 10 times, the air void structure being the only variable. For each concrete mix both air void analysis of the hardened concrete and a salt frost scaling test...

  16. Correlation dependence of the volumetric thermal expansion coefficient of metallic aluminum on its heat capacity

    Science.gov (United States)

    Bodryakov, V. Yu.; Bykov, A. A.

    2016-05-01

    The correlation between the volumetric thermal expansion coefficient β( T) and the heat capacity C( T) of aluminum is considered in detail. It is shown that a clear correlation is observed in a significantly wider temperature range, up to the melting temperature of the metal, along with the low-temperature range where it is linear. The significant deviation of dependence β( C) from the low-temperature linear behavior is observed up to the point where the heat capacity achieves the classical Dulong-Petit limit of 3 R ( R is the universal gas constant).

  17. Structuring feature space: a non-parametric method for volumetric transfer function generation.

    Science.gov (United States)

    Maciejewski, Ross; Woo, Insoo; Chen, Wei; Ebert, David S

    2009-01-01

    The use of multi-dimensional transfer functions for direct volume rendering has been shown to be an effective means of extracting materials and their boundaries for both scalar and multivariate data. The most common multi-dimensional transfer function consists of a two-dimensional (2D) histogram with axes representing a subset of the feature space (e.g., value vs. value gradient magnitude), with each entry in the 2D histogram being the number of voxels at a given feature space pair. Users then assign color and opacity to the voxel distributions within the given feature space through the use of interactive widgets (e.g., box, circular, triangular selection). Unfortunately, such tools lead users through a trial-and-error approach as they assess which data values within the feature space map to a given area of interest within the volumetric space. In this work, we propose the addition of non-parametric clustering within the transfer function feature space in order to extract patterns and guide transfer function generation. We apply a non-parametric kernel density estimation to group voxels of similar features within the 2D histogram. These groups are then binned and colored based on their estimated density, and the user may interactively grow and shrink the binned regions to explore feature boundaries and extract regions of interest. We also extend this scheme to temporal volumetric data in which time steps of 2D histograms are composited into a histogram volume. A three-dimensional (3D) density estimation is then applied, and users can explore regions within the feature space across time without adjusting the transfer function at each time step. Our work enables users to effectively explore the structures found within a feature space of the volume and provide a context in which the user can understand how these structures relate to their volumetric data. We provide tools for enhanced exploration and manipulation of the transfer function, and we show that the initial

  18. Accuracy of electrocardiographic-gated versus nongated volumetric intravascular ultrasound measurements of coronary arterial narrowing

    DEFF Research Database (Denmark)

    Jensen, Lisette Okkels; Thayssen, Per

    2007-01-01

    Intravascular ultrasound (IVUS) allows precise measurements of plaque plus media (P+M) volume and neointimal hyperplasia after coronary artery stenting. Conventional IVUS volumetric analysis is performed mostly without electrocardiographically gated acquisition, and the IVUS images are selected...... in changes between 2 electrocardiographically gated and 2 nongated pullbacks (lumen: 0.37 +/- 1.76 vs -0.23 +/- 2.32 mm(3), p = NS; EEM: 0.25 +/- 3.22 vs -0.94 +/- 4.27 mm(3), p = NS; P+M: -0.18 +/- 3.42 vs -0.74 +/- 3.88 mm(3), p = NS). In conclusion, in moderate atherosclerotic or stented coronary arteries...

  19. Constrained reverse diffusion for thick slice interpolation of 3D volumetric MRI images.

    Science.gov (United States)

    Neubert, Aleš; Salvado, Olivier; Acosta, Oscar; Bourgeat, Pierrick; Fripp, Jurgen

    2012-03-01

    Due to physical limitations inherent in magnetic resonance imaging scanners, three dimensional volumetric scans are often acquired with anisotropic voxel resolution. We investigate several interpolation approaches to reduce the anisotropy and present a novel approach - constrained reverse diffusion for thick slice interpolation. This technique was compared to common methods: linear and cubic B-Spline interpolation and a technique based on non-rigid registration of neighboring slices. The methods were evaluated on artificial MR phantoms and real MR scans of human brain. The constrained reverse diffusion approach delivered promising results and provides an alternative for thick slice interpolation, especially for higher anisotropy factors.

  20. Mass-conserved volumetric lattice Boltzmann method for complex flows with willfully moving boundaries.

    Science.gov (United States)

    Yu, Huidan; Chen, Xi; Wang, Zhiqiang; Deep, Debanjan; Lima, Everton; Zhao, Ye; Teague, Shawn D

    2014-06-01

    In this paper, we develop a mass-conserved volumetric lattice Boltzmann method (MCVLBM) for numerically solving fluid dynamics with willfully moving arbitrary boundaries. In MCVLBM, fluid particles are uniformly distributed in lattice cells and the lattice Boltzmann equations deal with the time evolution of the particle distribution function. By introducing a volumetric parameter P(x,y,z,t) defined as the occupation of solid volume in the cell, we distinguish three types of lattice cells in the simulation domain: solid cell (pure solid occupation, P=1), fluid cell (pure fluid occupation, P=0), and boundary cell (partial solid and partial fluid, 0Boltzmann equations are self-regularized through P and consist of three parts: (1) collision taking into account the momentum exchange between the willfully moving boundary and the flow; (2) streaming accompanying a volumetric bounce-back procedure in boundary cells; and (3) boundary-induced volumetric fluid migration moving the residual fluid particles into the flow domain when the boundary swipes over a boundary cell toward a solid cell. The MCVLBM strictly satisfies mass conservation and can handle irregular boundary orientation and motion with respect to the mesh. Validation studies are carried out in four cases. The first is to simulate fluid dynamics in syringes focusing on how MCVLBM captures the underlying physics of flow driven by a willfully moving piston. The second and third cases are two-dimensional (2D) peristaltic flow and three-dimensional (3D) pipe flow, respectively. In each case, we compare the MCVLBM simulation result with the analytical solution and achieve quantitatively good agreements. The fourth case is to simulate blood flow in human aortic arteries with a very complicated irregular boundary. We study steady flow in two dimensions and unsteady flow via the pulsation of the cardiac cycle in three dimensions. In the 2D case, both vector (velocity) and scalar (pressure) fields are compared to

  1. Cellular resolution volumetric in vivo retinal imaging with adaptive optics–optical coherence tomography◊

    Science.gov (United States)

    Zawadzki, Robert J.; Choi, Stacey S.; Fuller, Alfred R.; Evans, Julia W.; Hamann, Bernd; Werner, John S.

    2009-01-01

    Ultrahigh-resolution adaptive optics–optical coherence tomography (UHR-AO-OCT) instrumentation allowing monochromatic and chromatic aberration correction was used for volumetric in vivo retinal imaging of various retinal structures including the macula and optic nerve head (ONH). Novel visualization methods that simplify AO-OCT data viewing are presented, and include co-registration of AO-OCT volumes with fundus photography and stitching of multiple AO-OCT sub-volumes to create a large field of view (FOV) high-resolution volume. Additionally, we explored the utility of Interactive Science Publishing by linking all presented AO-OCT datasets with the OSA ISP software. PMID:19259248

  2. Cellular resolution volumetric in vivo retinal imaging with adaptive optics-optical coherence tomography.

    Science.gov (United States)

    Zawadzki, Robert J; Choi, Stacey S; Fuller, Alfred R; Evans, Julia W; Hamann, Bernd; Werner, John S

    2009-03-02

    Ultrahigh-resolution adaptive optics-optical coherence tomography (UHR-AO-OCT) instrumentation allowing monochromatic and chromatic aberration correction was used for volumetric in vivo retinal imaging of various retinal structures including the macula and optic nerve head (ONH). Novel visualization methods that simplify AO-OCT data viewing are presented, and include co-registration of AO-OCT volumes with fundus photography and stitching of multiple AO-OCT sub-volumes to create a large field of view (FOV) high-resolution volume. Additionally, we explored the utility of Interactive Science Publishing by linking all presented AO-OCT datasets with the OSA ISP software.

  3. Volumetric and Transport Properties of Aqueous NaB(OH)4 Solutions

    Institute of Scientific and Technical Information of China (English)

    周永全; 房春晖; 房艳; 朱发岩

    2013-01-01

    Density, pH, viscosity, conductivity and the Raman spectra of aqueous NaB(OH)4 solutions precisely measured as functions of concentration at different temperatures (293.15, 298.15, 303.15, 313.15 and 323.15 K) are presented. Polyborate distributions in aqueous NaB(OH)4 solution were calculated, covering all the concentration range, 4B(OH)− is the most dominant species, other polyborate anions are less than 5.0%. The volumetric and the transport properties were discussed in detail, both of these properties indicate that 4B(OH)− behaves as a struc-ture-disordered anion.

  4. Techniques to measure volumetric flow and particulate concentration in stacks with cyclonic flow

    Science.gov (United States)

    Sterrett, J. D.; Barbin, A. R.; Reece, J. W.; Carter, W. G.; Ferguson, B. B.

    1982-08-01

    It was determined that an in stack venturi can accurately measure volumetric flow in stacks with a severe cyclonic flow profile. The design requirements of the venturi are described. Also described was a low head loss, egg crate shaped device that effectively straightens cyclonic flow. Installation of such a device after a tangential inlet to a tall stack can result in considerable energy savings because it takes less fan power to push the straightened flow. Results to determine the particulate distribution downstream of the egg crate were inconclusive.

  5. Sensitivity of collapsed arc QA method for delivery errors in Volumetric Modulated Arc Therapy (VMAT)

    Science.gov (United States)

    Young, Tony; Xing, Aitang; Vial, Philp; Thwaites, David; Holloway, Lois; Arumugam, Sankar

    2015-01-01

    In this paper the sensitivity of an Electronic Portal Imaging Device (EPID) to detecting introduced Volumetric Arc Therapy (VMAT) treatment errors was studied using the Collapsed Arc method. Two clinical Head and Neck (H&N) and Prostate treatment plans had gantry dependent dose and MLC errors introduced to the plans. These plans were then delivered to an Elekta Synergy Linear Accelerator EPID and compared to the original treatment planning system Collapsed Arc dose matrix. With the Collapsed Arc technique the EPID was able to detect MLC errors down to 2mm and dose errors of down to 3% depending on the treatment plan complexity and gamma tolerance used.

  6. Real-time volumetric visualization of high-resolution array and toroidal volume search sonar data

    Science.gov (United States)

    Cross, Robert A.

    1998-09-01

    The Advanced Volume Visualization Display (AVVD) research program is a joint research program between the Fraunhofer Center for Research in Computer Graphics, Inc. and Innovative Research and Development Corp. It is dedicated the application of the human visual system to real-time visualization of high- resolution volumetric sensor data sets. The AVVD program has successfully demonstrated its application to undersea imaging using data from the Naval Undersea Warfare Center -- Division Newport's High Resolution Array (HRA), and from the Naval Surface Warfare Center -- Coastal System Stations's Toroidal Volume Search Sonar (TVSS).

  7. An Universal Modeling Method for Enhancing the Volumetric Accuracy of CNC Machine Tools

    Institute of Scientific and Technical Information of China (English)

    2002-01-01

    Volumetric error modeling method is an important te ch nique for enhancement the accuracy of CNC machine tools by error compensation. I n the research field, the main question is how to find an universal kinematics m odeling method for different kinds of NC machine tools. Multi-body system theor y is always used to solve the dynamics problem of complex physical system. But t ill now, the error factors that always exist in practice system is still not con sidered. In this paper, the accuracy kinematics of MB...

  8. Reconstruction of volumetric ultrasound panorama based on improved 3D SIFT.

    Science.gov (United States)

    Ni, Dong; Chui, Yim Pan; Qu, Yingge; Yang, Xuan; Qin, Jing; Wong, Tien-Tsin; Ho, Simon S H; Heng, Pheng Ann

    2009-10-01

    Registration of ultrasound volumes is a key issue for the reconstruction of volumetric ultrasound panorama. In this paper, we propose an improved three-dimensional (3D) scale invariant feature transform (SIFT) algorithm to globally register ultrasound volumes acquired from dedicated ultrasound probe, where local deformations are corrected by block-based warping algorithm. Original SIFT algorithm is extended to 3D and improved by combining the SIFT detector with Rohr3D detector to extract complementary features and applying the diffusion distance algorithm for robust feature comparison. Extensive experiments have been performed on both phantom and clinical data sets to demonstrate the effectiveness and robustness of our approach.

  9. Direct volumetric rendering based on point primitives in OpenGL.

    Science.gov (United States)

    da Rosa, André Luiz Miranda; de Almeida Souza, Ilana; Yuuji Hira, Adilson; Zuffo, Marcelo Knörich

    2006-01-01

    The aim of this project is to present a renderization by software algorithm of acquired volumetric data. The algorithm was implemented in Java language and the LWJGL graphical library was used, allowing the volume renderization by software and thus preventing the necessity to acquire specific graphical boards for the 3D reconstruction. The considered algorithm creates a model in OpenGL, through point primitives, where each voxel becomes a point with the color values related to this pixel position in the corresponding images.

  10. High light extraction efficiency in bulk-GaN based volumetric violet light-emitting diodes

    Energy Technology Data Exchange (ETDEWEB)

    David, Aurelien, E-mail: adavid@soraa.com; Hurni, Christophe A.; Aldaz, Rafael I.; Cich, Michael J.; Ellis, Bryan; Huang, Kevin; Steranka, Frank M.; Krames, Michael R. [Soraa Inc., 6500 Kaiser Dr., Fremont, California 94555 (United States)

    2014-12-08

    We report on the light extraction efficiency of III-Nitride violet light-emitting diodes with a volumetric flip-chip architecture. We introduce an accurate optical model to account for light extraction. We fabricate a series of devices with varying optical configurations and fit their measured performance with our model. We show the importance of second-order optical effects like photon recycling and residual surface roughness to account for data. We conclude that our devices reach an extraction efficiency of 89%.

  11. The frontal and temporal horn ratio to assess dimension of paediatric hydrocephalus: a comparative volumetric study.

    Science.gov (United States)

    Antes, Sebastian; Welsch, Melanie; Kiefer, Michael; Gläser, Mareike; Körner, Heiko; Eymann, Regina

    2013-01-01

    Magnetic resonance imaging and cranial -ultrasound are the most frequently implemented imaging methods for investigating the infantile hydrocephalic brain. A general and reliable measurement index that can be equally applied in both imaging methods to assess dimension of ventricular dilatation is currently not available. For this purpose, a new parameter called the frontal and temporal horn ratio - determinable in coronal slices of the brain - was developed and evaluated in a comparative volumetric retrospective study: Statistical analyses of 118 MRIs of 46 different shunt-treated pediatric patients revealed a good linear correlation between the new index and the actual ventricular volume.

  12. Enhancing Volumetric Bouligand-Minkowski Fractal Descriptors by using Functional Data Analysis

    CERN Document Server

    Florindo, João Batista; Bruno, Odemir Martinez; 10.1142/S0129183111016701

    2012-01-01

    This work proposes and study the concept of Functional Data Analysis transform, applying it to the performance improving of volumetric Bouligand-Minkowski fractal descriptors. The proposed transform consists essentially in changing the descriptors originally defined in the space of the calculus of fractal dimension into the space of coefficients used in the functional data representation of these descriptors. The transformed decriptors are used here in texture classification problems. The enhancement provided by the FDA transform is measured by comparing the transformed to the original descriptors in terms of the correctness rate in the classification of well known datasets.

  13. 3D Volumetric Modeling and Microvascular Reconstruction of Irradiated Lumbosacral Defects After Oncologic Resection

    Directory of Open Access Journals (Sweden)

    Emilio Garcia-Tutor

    2016-12-01

    Full Text Available Background: Locoregional flaps are sufficient in most sacral reconstructions. However, large sacral defects due to malignancy necessitate a different reconstructive approach, with local flaps compromised by radiation and regional flaps inadequate for broad surface areas or substantial volume obliteration. In this report, we present our experience using free muscle transfer for volumetric reconstruction in such cases, and demonstrate 3D haptic models of the sacral defect to aid preoperative planning.Methods: Five consecutive patients with irradiated sacral defects secondary to oncologic resections were included, surface area ranging from 143-600cm2. Latissimus dorsi-based free flap sacral reconstruction was performed in each case, between 2005 and 2011. Where the superior gluteal artery was compromised, the subcostal artery was used as a recipient vessel. Microvascular technique, complications and outcomes are reported. The use of volumetric analysis and 3D printing is also demonstrated, with imaging data converted to 3D images suitable for 3D printing with Osirix software (Pixmeo, Geneva, Switzerland. An office-based, desktop 3D printer was used to print 3D models of sacral defects, used to demonstrate surface area and contour and produce a volumetric print of the dead space needed for flap obliteration. Results: The clinical series of latissimus dorsi free flap reconstructions is presented, with successful transfer in all cases, and adequate soft-tissue cover and volume obliteration achieved. The original use of the subcostal artery as a recipient vessel was successfully achieved. All wounds healed uneventfully. 3D printing is also demonstrated as a useful tool for 3D evaluation of volume and dead-space.Conclusion: Free flaps offer unique benefits in sacral reconstruction where local tissue is compromised by irradiation and tumor recurrence, and dead-space requires accurate volumetric reconstruction. We describe for the first time the use of

  14. Finite element analysis of volumetrically heated fluids in an axisymmetric enclosure

    Energy Technology Data Exchange (ETDEWEB)

    Gartling, D.K.

    1979-01-01

    A general purpose finite element computer code has been used to analyze the steady state and transient response of a confined fluid that is heated volumetrically. The numerical procedure is demonstrated to be capable of resolving flow fields of considerable complexity without undue computational expense. Results are discussed for a Grashof number range (4.0 x 10/sup 4/ to 4.0 x 10/sup 6/) in which the flow varies from a steady, single cell configuration to a multiple cell configuration that includes a periodic interaction.

  15. Two-dimensional catheter arrays for real-time intracardiac volumetric imaging

    Science.gov (United States)

    Light, Edward D.; Fiering, Jason O.; Lee, Warren; Wolf, Patrick D.; Smith, Stephen W.

    1999-06-01

    We have previously described 2D arrays of several thousand elements operating up to 5.0 MHz for transthoracic cardiac imaging. Lately, there has been interest in developing catheter based intracardiac imaging systems to aid in the precise tracking of anatomical features for improved diagnoses and therapies. We have constructed several arrays for real time intracardiac volumetric imaging based upon two different designs; a 10 X 10 equals 100 element 5.0 MHz forward looking 2D array, and a 13 X 11 equals 143 element 5.0 MHz 2D array for side scanning applications.

  16. Are adult patients with Laron syndrome osteopenic? A comparison between dual-energy X-ray absorptiometry and volumetric bone densities.

    Science.gov (United States)

    Benbassat, Carlos A; Eshed, Varda; Kamjin, Moshe; Laron, Zvi

    2003-10-01

    Severe short stature resulting from a deficiency in IGF-I is a prominent feature of Laron syndrome (LS). Although low bone mineral density (BMD) has been noted in LS patients examined by dual energy x-ray absorptiometry (DEXA), this technique does not take volume into account and may therefore underestimate the true bone density in patients with small bones. The aim of the present study was to evaluate the BMD yielded by DEXA in our LS patients using estimated volumetric values. Volumetric density was calculated with the following formulas: bone mineral apparent density (BMAD) = bone mineral content (BMC)/(area)(3/2) for the lumbar spine and BMAD = BMC/area(2) for the femoral neck. The study sample included 12 patients (mean age, 43.9 yr; mean height, 123.7 cm). Findings were compared with 10 osteopenic subjects without developmental abnormalities (mean age, 56 yr; mean height, 164.8 cm) and 10 healthy control subjects matched for sex and age to the LS patients (mean height, 165.5 cm). BMAD in the LS group was 0.201 +/- 0.02 g/cm(3) at the lumbar spine and 0.201 +/- 0.04 g/cm(3) at the femoral neck; corresponding values for the osteopenic group were 0.130 +/- 0.01 and 0.140 +/- 0.01 g/cm(3), and for the controls, 0.178 +/- 0.03 and 0.192 +/- 0.02 g/cm(3). Although areal BMD was significantly lower in the LS and osteopenic subjects compared with controls (P < 0.02) at both the lumbar spine and femoral neck, BMAD was low (P < 0.01) in the osteopenic group only. In conclusion, DEXA does not seem to be a reliable measure of osteoporosis in patients with LS.

  17. GSPEL - Air Filtration Laboratory

    Data.gov (United States)

    Federal Laboratory Consortium — Evaluation capabilities for air filtration devices The Air Filtration Lab provides testing of air filtration devices to demonstrate and validate new or legacy system...

  18. Air filtration and indoor air quality

    DEFF Research Database (Denmark)

    Bekö, Gabriel

    2006-01-01

    Demands for better indoor air quality are increasing, since we spend most of our time indoors and we are more and more aware of indoor air pollution. Field studies in different parts of the world have documented that high percentage of occupants in many offices and buildings find the indoor air...... decent ventilation and air cleaning/air filtration, high indoor air quality cannot be accomplished. The need for effective air filtration has increased with increasing evidence on the hazardous effects of fine particles. Moreover, the air contains gaseous pollutants, removal of which requires various air...... cleaning techniques. Supply air filter is one of the key components in the ventilation system. Studies have shown that used ventilation filters themselves can be a significant source of indoor air pollution with consequent impact on perceived air quality, sick building syndrome symptoms and performance...

  19. Digital Content Strategies

    OpenAIRE

    Daniel Halbheer; Florian Stahl; Oded Koenigsberg; Lehmann, Donald R

    2013-01-01

    This paper studies content strategies for online publishers of digital information goods. It examines sampling strategies and compares their performance to paid content and free content strategies. A sampling strategy, where some of the content is offered for free and consumers are charged for access to the rest, is known as a "metered model" in the newspaper industry. We analyze optimal decisions concerning the size of the sample and the price of the paid content when sampling serves the dua...

  20. Densely-packed graphene/conducting polymer nanoparticle papers for high-volumetric-performance flexible all-solid-state supercapacitors

    Science.gov (United States)

    Yang, Chao; Zhang, Liling; Hu, Nantao; Yang, Zhi; Wei, Hao; Xu, Zhichuan J.; Wang, Yanyan; Zhang, Yafei

    2016-08-01

    Graphene-based all-solid-state supercapacitors (ASSSCs) are one of the most ideal candidates for high-performance flexible power sources. The achievement of high volumetric energy density is highly desired for practical application of this type of ASSSCs. Here, we present a facile method to boost volumetric performances of graphene-based flexible ASSSCs through incorporation of ultrafine polyaniline-poly(4-styrenesulfonate) (PANI-PSS) nanoparticles in reduced graphene oxide (rGO) papers. A compact structure is obtained via intimate contact and π-π interaction between PANI-PSS nanoparticles and rGO sheets. The hybrid paper electrode with the film thickness of 13.5 μm, shows an extremely high volumetric specific capacitance of 272 F/cm3 (0.37 A/cm3 in a three-electrode cell). The assembled ASSSCs show a large volumetric specific capacitance of 217 F/cm3 (0.37 A/cm3 in a two-electrode cell), high volumetric energy and power density, excellent capacitance stability, small leakage current as well as low self-discharge characteristics, revealing the usefulness of this robust hybrid paper for high-performance flexible energy storage devices.

  1. Fast Estimation of Dietary Fiber Content in Apple

    OpenAIRE

    Le Gall, Sophie; Even, Sonia; Lahaye, Marc

    2016-01-01

    Dietary fibers (DF) are one of the nutritional benefits of fleshy fruit consumption that is becoming a quality criterion for genetic selection by breeders. However, the AOAC total DF content determination is not readily amenable for screening large fruit collections. A new screening method of DF content in an apple collection based on the automated preparation of cell wall material as an alcohol-insoluble residue (AIR) is proposed. The yield of AIR from 27 apple genotypes was compared with DF...

  2. Evaluation of solar-air-heating central-receiver concepts

    Energy Technology Data Exchange (ETDEWEB)

    Bird, S.P.; Drost, M.K.; Williams, T.A.; Brown, D.R.; Fort, J.A.; Garrett-Price, B.A.; Hauser, S.G.; McLean, M.A.; Paluszek, A.M.; Young, J.K.

    1982-06-01

    The potential of seven proposed air-heating central receiver concepts are evaluated based on an independent, uniform of each one's performance and cost. The concepts include: metal tubes, ceramic tubes, sodium heat pipes, ceramic matrix, ceramic domes, small particles, and volumetric heat exchange. The selection of design points considered in the analysis, the method and ground rules used in formulating the conceptual designs are discussed, and each concept design is briefly described. The method, ground rules, and models used in the performance evaluation and cost analysis and the results are presented. (LEW)

  3. The Hubble Space Telescope Cluster Supernova Survey: VI. The Volumetric Type Ia Supernova Rate

    CERN Document Server

    Barbary, K; Amanullah, R; Brodwin, M; Connolly, N; Dawson, K S; Doi, M; Eisenhardt, P; Faccioli, L; Fadeyev, V; Fakhouri, H K; Fruchter, A S; Gilbank, D G; Gladders, M D; Goldhaber, G; Goobar, A; Hattori, T; Hsiao, E; Huang, X; Ihara, Y; Kashikawa, N; Koester, B; Konishi, K; Kowalski, M; Lidman, C; Lubin, L; Meyers, J; Morokuma, T; Oda, T; Panagia, N; Perlmutter, S; Postman, M; Ripoche, P; Rosati, P; Rubin, D; Schlegel, D J; Spadafora, A L; Stanford, S A; Strovink, M; Suzuki, N; Takanashi, N; Tokita, K; Yasuda, N

    2011-01-01

    We present a measurement of the volumetric Type Ia supernova (SN Ia) rate out to z ~ 1.6 from the Hubble Space Telescope Cluster Supernova Survey. In observations spanning 189 orbits with the Advanced Camera for Surveys we discovered 29 SNe, of which approximately 20 are SNe Ia. Twelve of these SNe Ia are located in the foregrounds and backgrounds of the clusters targeted in the survey. Using these new data, we derive the volumetric SN Ia rate in four broad redshift bins, finding results consistent with previous measurements at z > 1 and strengthening the case for a SN Ia rate that is equal to or greater than ~0.6 x 10^-4/yr/Mpc^3 at z ~ 1 and flattening out at higher redshift. We provide SN candidates and efficiency calculations in a form that makes it easy to rebin and combine these results with other measurements for increased statistics. Finally, we compare the assumptions about host-galaxy dust extinction used in different high-redshift rate measurements, finding that different assumptions may induce sig...

  4. Theory of Volumetric Moving Dislocation in Poroelastic Halfspace and Characterization of Magma Intrusion Events

    Institute of Scientific and Technical Information of China (English)

    Ouyang Zhihua; Elsworth Derek; Sheng Jianlong

    2005-01-01

    The undrained change in pore fluid pressure that accompanies dike intrusion may be conveniently represented as a moving volumetric dislocation. The concept of a dilation center was developed to represent the field of undrained pressure change in a saturated linear elastic medium. Since instantaneous pore fluid pressures can be developed to a considerable distance from the dislocation, monitoring the rate of pressure generation and subsequent pressure dissipation in a fully coupled manner enables certain characteristics of the resulting dislocation to be defined. The principal focus of this study is the application of dislocation-based methods to analyze the behavior of the fluid pressure response induced by intrusive dislocations in a semi-infinite space, such as dike intrusion, hydraulic fracturing and piezometer insertion. Partially drained pore pressures result from the isothermal introduction of volumetric moving pencil-like dislocations described as analogs to moving point dislocation within a semi-infinite saturated elastic medium. To represent behavior within the halfspace, an image dislocation is positioned under the moving coordinate frame fixed to the front of the primary moving dislocation, to yield an approximate solution for pore pressure for constant fluid pressure conditions. Induced pore pressures are concisely described under a minimum set of dimensionless parameter groupings representing propagation velocity, and relative geometry. Charts defining induced pore fluid pressure at a static measuring point provide a meaningful tool for determining unknown parameters in data reduction. Two intrusive events at Krafla, Iceland are examined using the type curve matching techniques. Predicted parameters agree favorably with field data.

  5. Optimal spacing within a tubed, volumetric, cavity receiver suitable for modular molten salt solar towers

    Science.gov (United States)

    Turner, Peter

    2016-05-01

    A 2-dimensional radiation analysis has been developed to analyse the radiative efficiency of an arrangement of heat transfer tubes distributed in layers but spaced apart to form a tubed, volumetric receiver. Such an arrangement could be suitable for incorporation into a cavity receiver. Much of the benefit of this volumetric approach is gained after using 5 layers although improvements do continue with further layers. The radiation analysis splits each tube into multiple segments in which each segment surface can absorb, reflect and radiate rays depending on its surface temperature. An iterative technique is used to calculate appropriate temperatures depending on the distribution of the net energy absorbed and assuming that the cool heat transfer fluid (molten salt) starts at the front layer and flows back through successive layers to the rear of the cavity. Modelling the finite diameter of each layer of tubes increases the ability of a layer to block radiation scattered at acute angles and this effect is shown to reduce radiation losses by nearly 25% compared to the earlier 1-d analysis. Optimum efficient designs tend to occur when the blockage factor is 0.2 plus the inverse of the number of tube layers. It is beneficial if the distance between successive layers is ≥ 2 times the diameter of individual tubes and in this situation, if the incoming radiation is spread over a range of angles, the performance is insensitive to the degree of any tube positional offset or stagger between layers.

  6. Volumetrics of CO{sub 2} Storage in Deep Saline Formations

    Energy Technology Data Exchange (ETDEWEB)

    Steele-MacInnis, Matthew; Capobianco, Ryan M; Dilmore, Robert; Goodman, Angela; Guthrie, George; Rimstidt, J Donald; Bodnar, Robert J

    2013-01-01

    Concern about the role of greenhouse gases in global climate change has generated interest in sequestering CO{sub 2} from fossil-fuel combustion in deep saline formations. Pore space in these formations is initially filled with brine, and space to accommodate injected CO{sub 2} must be generated by displacing brine, and to a lesser extent by compression of brine and rock. The formation volume required to store a given mass of CO{sub 2} depends on the storage mechanism. We compare the equilibrium volumetric requirements of three end-member processes: CO{sub 2} stored as a supercritical fluid (structural or stratigraphic trapping); CO{sub 2} dissolved in pre-existing brine (solubility trapping); and CO{sub 2} solubility enhanced by dissolution of calcite. For typical storage conditions, storing CO{sub 2} by solubility trapping reduces the volume required to store the same amount of CO{sub 2} by structural or stratigraphic trapping by about 50%. Accessibility of CO{sub 2} to brine determines which storage mechanism (structural/stratigraphic versus solubility) dominates at a given time, which is a critical factor in evaluating CO{sub 2} volumetric requirements and long-term storage security.

  7. Early clinical experience with volumetric modulated arc therapy in head and neck cancer patients

    Directory of Open Access Journals (Sweden)

    Cozzi Luca

    2010-10-01

    Full Text Available Abstract Background To report about early clinical experience in radiation treatment of head and neck cancer of different sites and histology by volumetric modulated arcs with the RapidArc technology. Methods During 2009, 45 patients were treated at Istituto Clinico Humanitas with RapidArc (28 males and 17 females, median age 65 years. Of these, 78% received concomitant chemotherapy. Thirty-six patients were treated as exclusive curative intent (group A, three as postoperative curative intent (group B and six with sinonasal tumours (group C. Dose prescription was at Planning Target Volumes (PTV with simultaneous integrated boost: 54.45Gy and 69.96Gy in 33 fractions (group A; 54.45Gy and 66Gy in 33 fractions (group B and 55Gy in 25 fractions (group C. Results Concerning planning optimization strategies and constraints, as per PTV coverage, for all groups, D98% > 95% and V95% > 99%. As regards organs at risk, all planning objectives were respected, and this was correlated with observed acute toxicity rates. Only 28% of patients experienced G3 mucositis, 14% G3 dermitis 44% had G2 dysphagia. Nobody required feeding tubes to be placed during treatment. Acute toxicity is also related to chemotherapy. Two patients interrupted the course of radiotherapy because of a quick worsening of general clinical condition. Conclusions These preliminary results stated that volumetric modulated arc therapy in locally advanced head and neck cancers is feasible and effective, with acceptable toxicities.

  8. Volumetric synthetic aperture imaging with a piezoelectric 2D row-column probe

    Science.gov (United States)

    Bouzari, Hamed; Engholm, Mathias; Christiansen, Thomas Lehrmann; Beers, Christopher; Lei, Anders; Stuart, Matthias Bo; Nikolov, Svetoslav Ivanov; Thomsen, Erik Vilain; Jensen, Jørgen Arendt

    2016-04-01

    The synthetic aperture (SA) technique can be used for achieving real-time volumetric ultrasound imaging using 2-D row-column addressed transducers. This paper investigates SA volumetric imaging performance of an in-house prototyped 3 MHz λ/2-pitch 62+62 element piezoelectric 2-D row-column addressed transducer array. Utilizing single element transmit events, a volume rate of 90 Hz down to 14 cm deep is achieved. Data are obtained using the experimental ultrasound scanner SARUS with a 70 MHz sampling frequency and beamformed using a delay-and-sum (DAS) approach. A signal-to-noise ratio of up to 32 dB is measured on the beamformed images of a tissue mimicking phantom with attenuation of 0.5 dB cm-1 MHz-1, from the surface of the probe to the penetration depth of 300λ. Measured lateral resolution as Full-Width-at-Half-Maximum (FWHM) is between 4λ and 10λ for 18% to 65% of the penetration depth from the surface of the probe. The averaged contrast is 13 dB for the same range. The imaging performance assessment results may represent a reference guide for possible applications of such an array in different medical fields.

  9. Mammographic density measurement: a comparison of automated volumetric density measurement to BIRADS

    Science.gov (United States)

    McEntee, Mark F.; Damases, Christine N.

    2014-03-01

    The aim of this study is to compare mammographic breast density assessment with automated volumetric software with Breast Imaging Reporting and Data System (BIRADS) categorization by radiologists on two imaging systems. A data set of 120 mammograms was classified by twenty American Board of Radiology (ABR) Examiners. The mammograms were of 20 women (mean age, 60 years; range, 42-89 years). These women were image twice once with GE system and the following year with Hologic system. These images also had their volumetric density classified by using Volpara Density Grade (VDG). The radiologists were asked to estimate the mammographic density according to BIRADS categories (1- 4). There was a moderate agreement between VDG classification and radiologist BIRADS density shown with Cohen's Kappa (K=0.45; pBIRADS having a mean of 2.13 and the mean VDG higher at 2.50 (t = -11.99; pBIRADS showed a positive strong correlation (r=0.84; pBIRADS and VDG AvBD% also showed a strong positive correlation (r=0.86; pBIRADS categories for each of the VDG AvBD% classifications. Using Volpara, the Hologic system showed a higher meanAvBD% (10.02 vs. 9.97). However using BIRADS the Hologic systems showed a lower mean (2.05 vs. 2.21). Automated systems demonstrated higher internal validity. The results demonstrated a moderate agreement and a strong correlation between VDG classification and radiologist BIRADS density assessment.

  10. Impact of Turbocharger Non-Adiabatic Operation on Engine Volumetric Efficiency and Turbo Lag

    Directory of Open Access Journals (Sweden)

    S. Shaaban

    2012-01-01

    Full Text Available Turbocharger performance significantly affects the thermodynamic properties of the working fluid at engine boundaries and hence engine performance. Heat transfer takes place under all circumstances during turbocharger operation. This heat transfer affects the power produced by the turbine, the power consumed by the compressor, and the engine volumetric efficiency. Therefore, non-adiabatic turbocharger performance can restrict the engine charging process and hence engine performance. The present research work investigates the effect of turbocharger non-adiabatic performance on the engine charging process and turbo lag. Two passenger car turbochargers are experimentally and theoretically investigated. The effect of turbine casing insulation is also explored. The present investigation shows that thermal energy is transferred to the compressor under all circumstances. At high rotational speeds, thermal energy is first transferred to the compressor and latter from the compressor to the ambient. Therefore, the compressor appears to be “adiabatic” at high rotational speeds despite the complex heat transfer processes inside the compressor. A tangible effect of turbocharger non-adiabatic performance on the charging process is identified at turbocharger part load operation. The turbine power is the most affected operating parameter, followed by the engine volumetric efficiency. Insulating the turbine is recommended for reducing the turbine size and the turbo lag.

  11. Numerical analysis of radiation propagation in innovative volumetric receivers based on selective laser melting techniques

    Science.gov (United States)

    Alberti, Fabrizio; Santiago, Sergio; Roccabruna, Mattia; Luque, Salvador; Gonzalez-Aguilar, Jose; Crema, Luigi; Romero, Manuel

    2016-05-01

    Volumetric absorbers constitute one of the key elements in order to achieve high thermal conversion efficiencies in concentrating solar power plants. Regardless of the working fluid or thermodynamic cycle employed, design trends towards higher absorber output temperatures are widespread, which lead to the general need of components of high solar absorptance, high conduction within the receiver material, high internal convection, low radiative and convective heat losses and high mechanical durability. In this context, the use of advanced manufacturing techniques, such as selective laser melting, has allowed for the fabrication of intricate geometries that are capable of fulfilling the previous requirements. This paper presents a parametric design and analysis of the optical performance of volumetric absorbers of variable porosity conducted by means of detailed numerical ray tracing simulations. Sections of variable macroscopic porosity along the absorber depth were constructed by the fractal growth of single-cell structures. Measures of performance analyzed include optical reflection losses from the absorber front and rear faces, penetration of radiation inside the absorber volume, and radiation absorption as a function of absorber depth. The effects of engineering design parameters such as absorber length and wall thickness, material reflectance and porosity distribution on the optical performance of absorbers are discussed, and general design guidelines are given.

  12. Multitracer: a Java-based tool for anatomic delineation of grayscale volumetric images.

    Science.gov (United States)

    Woods, Roger P

    2003-08-01

    A Java-based tool for delineating anatomic boundaries in 8- and 16- bit grayscale volumetric images is described. Modern features implemented by the tool include the ability to simultaneously view the current cursor position and the previously delineated boundaries on three orthogonal planes, the ability to magnify images during delineation using high-quality interpolation, the ability to encode and save boundaries with subvoxel resolution, and the ability to utilize coregistered images interchangeably during delineation. Additional features facilitate use of the tool in a multiuser, multiplatform environment and provide support for the documentation of anatomic delineation protocols. In addition to providing direct estimates of structure volumes, areas, and lengths, the tool allows contoured boundaries to be exported for more sophisticated analyses. The tool also provides support for manual editing of image volumes to remove confounding structures and for manual correction of image volumes that have been inaccurately edited. In addition to its research utility, the tool also has potential value in education, allowing students to interact with volumetric data and structural boundaries in three dimensions.

  13. Volumetric characterization of human patellar cartilage matrix on phase contrast x-ray computed tomography

    Science.gov (United States)

    Abidin, Anas Z.; Nagarajan, Mahesh B.; Checefsky, Walter A.; Coan, Paola; Diemoz, Paul C.; Hobbs, Susan K.; Huber, Markus B.; Wismüller, Axel

    2015-03-01

    Phase contrast X-ray computed tomography (PCI-CT) has recently emerged as a novel imaging technique that allows visualization of cartilage soft tissue, subsequent examination of chondrocyte patterns, and their correlation to osteoarthritis. Previous studies have shown that 2D texture features are effective at distinguishing between healthy and osteoarthritic regions of interest annotated in the radial zone of cartilage matrix on PCI-CT images. In this study, we further extend the texture analysis to 3D and investigate the ability of volumetric texture features at characterizing chondrocyte patterns in the cartilage matrix for purposes of classification. Here, we extracted volumetric texture features derived from Minkowski Functionals and gray-level co-occurrence matrices (GLCM) from 496 volumes of interest (VOI) annotated on PCI-CT images of human patellar cartilage specimens. The extracted features were then used in a machine-learning task involving support vector regression to classify ROIs as healthy or osteoarthritic. Classification performance was evaluated using the area under the receiver operating characteristic (ROC) curve (AUC). The best classification performance was observed with GLCM features correlation (AUC = 0.83 +/- 0.06) and homogeneity (AUC = 0.82 +/- 0.07), which significantly outperformed all Minkowski Functionals (p GLCM-derived statistical features can distinguish between healthy and osteoarthritic tissue with high accuracy.

  14. Volumetric texture analysis of breast lesions on contrast-enhanced magnetic resonance images.

    Science.gov (United States)

    Chen, Weijie; Giger, Maryellen L; Li, Hui; Bick, Ulrich; Newstead, Gillian M

    2007-09-01

    Automated image analysis aims to extract relevant information from contrast-enhanced magnetic resonance images (CE-MRI) of the breast and improve the accuracy and consistency of image interpretation. In this work, we extend the traditional 2D gray-level co-occurrence matrix (GLCM) method to investigate a volumetric texture analysis approach and apply it for the characterization of breast MR lesions. Our database of breast MR images was obtained using a T1-weighted 3D spoiled gradient echo sequence and consists of 121 biopsy-proven lesions (77 malignant and 44 benign). A fuzzy c-means clustering (FCM) based method is employed to automatically segment 3D breast lesions on CE-MR images. For each 3D lesion, a nondirectional GLCM is then computed on the first postcontrast frame by summing 13 directional GLCMs. Texture features are extracted from the nondirectional GLCMs and the performance of each texture feature in the task of distinguishing between malignant and benign breast lesions is assessed by receiver operating characteristics (ROC) analysis. Our results show that the classification performance of volumetric texture features is significantly better than that based on 2D analysis. Our investigations of the effects of various of parameters on the diagnostic accuracy provided means for the optimal use of the approach.

  15. Sperm volumetric dynamics during in vitro capacitation process in bovine spermatozoa.

    Science.gov (United States)

    García-Herreros, M; Leal, C L V

    2015-06-01

    Previous studies have demonstrated that sperm head morphometry can be used as a potential diagnostic tool for detecting biophysical changes associated with sperm viability in bovine spermatozoa. In this study, sperm head morphometry was used to investigate its value as a biophysical marker for detecting volumetric changes in bovine spermatozoa under in vitro capacitating and non-capacitating incubation conditions. To further test this hypotesis, aliquots of pooled, washed bovine sperm were incubated in either Tyrode's complete medium with heparin (TCMH; a capacitating medium containing Ca2+, NaHCO3 and heparin), Tyrode's complete medium heparin-free (TCM; a medium containing just Ca2+ and NaHCO3) or Tyrode's basal medium (TBM; a non-capacitating medium free of Ca2+, NaHCO3 and heparin, used as control). Aliquots of sperm were processed for morphometric analysis at different incubation-time intervals (0, 3 and 6 h at 38°C), and the chlortetracycline assay was used simultaneously to confirm the ability of the sperm to undergo capacitation (B pattern) and the acrosome reaction (AR pattern) status in each medium. After 3 h of incubation under TCMH conditions, a significant increase was observed in the percentage of B and AR patterns and a significant decrease was found in all sperm morphometric parameters (Psperm size and AR pattern (r=-0.875, Psperm head morphometry can be used as a potential biophysical marker for detecting volumetric changes during capacitation process in bovine spermatozoa.

  16. High-throughput volumetric reconstruction for 3D wheat plant architecture studies

    Directory of Open Access Journals (Sweden)

    Wei Fang

    2016-09-01

    Full Text Available For many tiller crops, the plant architecture (PA, including the plant fresh weight, plant height, number of tillers, tiller angle and stem diameter, significantly affects the grain yield. In this study, we propose a method based on volumetric reconstruction for high-throughput three-dimensional (3D wheat PA studies. The proposed methodology involves plant volumetric reconstruction from multiple images, plant model processing and phenotypic parameter estimation and analysis. This study was performed on 80 Triticum aestivum plants, and the results were analyzed. Comparing the automated measurements with manual measurements, the mean absolute percentage error (MAPE in the plant height and the plant fresh weight was 2.71% (1.08cm with an average plant height of 40.07cm and 10.06% (1.41g with an average plant fresh weight of 14.06g, respectively. The root mean square error (RMSE was 1.37cm and 1.79g for the plant height and plant fresh weight, respectively. The correlation coefficients were 0.95 and 0.96 for the plant height and plant fresh weight, respectively. Additionally, the proposed methodology, including plant reconstruction, model processing and trait extraction, required only approximately 20s on average per plant using parallel computing on a graphics processing unit (GPU, demonstrating that the methodology would be valuable for a high-throughput phenotyping platform.

  17. Volumetric localization of epileptic activities in tuberous sclerosis using synthetic aperture magnetometry

    Energy Technology Data Exchange (ETDEWEB)

    Xiao, Zheng [Hospital for Sick Children, Research Institute, Toronto (Canada); Hospital for Sick Children, Department of Diagnostic Imaging, Toronto (Canada); Xiang, Jing [Hospital for Sick Children, Research Institute, Toronto (Canada); Hospital for Sick Children, Department of Diagnostic Imaging, Toronto (Canada); Holowka, Stephanie; Chuang, Sylvester [Hospital for Sick Children, Department of Diagnostic Imaging, Toronto (Canada); Hunjan, Amrita; Sharma, Rohit; Otsubo, Hiroshi [Hospital for Sick Children, Division of Neurology, Toronto (Canada)

    2006-01-01

    Magnetoencephalography (MEG) is a novel noninvasive technique for localizing epileptic zones. Tuberous sclerosis complex (TSC) is often associated with medically refractory epilepsy with multiple epileptic zones. Surgical treatment of TSC requires accurate localization of epileptogenic tubers. The objective of this study was to introduce a new MEG technique, synthetic aperture magnetometry (SAM), to volumetrically localize irritable zones and clarify the correlations between SAM, dipole modeling and anatomical tubers. Eight pediatric patients with TSC confirmed by clinical and neuroimaging findings were retrospectively studied. MEG data were recorded using a whole-cortex CTF OMEGA system. Sleep deprivation was employed to provoke epileptiform activity. Irritable zones were localized using both dipole modeling and SAM. MRI detected 42 tubers in the eight patients. Dipole modeling localized 28 irritable zones, and 19 out of the 28 zones were near tubers (19/42, 45%). SAM found 51 irritable zones, and 31 out of the 51 zones were near tubers (31/42, 74%). Among the 51 irritable zones determined by SAM, thirty-five zones were in 1-35 Hz, nine zones were in 35-60 Hz, and seven zones were in 60-120 Hz. The new method, SAM, yielded very plausible equivalent sources for patients who showed anatomical tubers on MRI. Compared to conventional dipole modeling, SAM appeared to offer increased detection of irritable zones and beneficial volumetric and frequency descriptions. (orig.)

  18. Volumetric Medical Image Coding: An Object-based, Lossy-to-lossless and Fully Scalable Approach.

    Science.gov (United States)

    Danyali, Habibiollah; Mertins, Alfred

    2011-01-01

    In this article, an object-based, highly scalable, lossy-to-lossless 3D wavelet coding approach for volumetric medical image data (e.g., magnetic resonance (MR) and computed tomography (CT)) is proposed. The new method, called 3DOBHS-SPIHT, is based on the well-known set partitioning in the hierarchical trees (SPIHT) algorithm and supports both quality and resolution scalability. The 3D input data is grouped into groups of slices (GOS) and each GOS is encoded and decoded as a separate unit. The symmetric tree definition of the original 3DSPIHT is improved by introducing a new asymmetric tree structure. While preserving the compression efficiency, the new tree structure allows for a small size of each GOS, which not only reduces memory consumption during the encoding and decoding processes, but also facilitates more efficient random access to certain segments of slices. To achieve more compression efficiency, the algorithm only encodes the main object of interest in each 3D data set, which can have any arbitrary shape, and ignores the unnecessary background. The experimental results on some MR data sets show the good performance of the 3DOBHS-SPIHT algorithm for multi-resolution lossy-to-lossless coding. The compression efficiency, full scalability, and object-based features of the proposed approach, beside its lossy-to-lossless coding support, make it a very attractive candidate for volumetric medical image information archiving and transmission applications.

  19. Volumetric capnography: In the diagnostic work-up of chronic thromboembolic disease

    Directory of Open Access Journals (Sweden)

    Marcos Mello Moreira

    2010-05-01

    Full Text Available Marcos Mello Moreira1, Renato Giuseppe Giovanni Terzi1, Laura Cortellazzi2, Antonio Luis Eiras Falcão1, Heitor Moreno Junior2, Luiz Cláudio Martins2, Otavio Rizzi Coelho21Department of Surgery, 2Department of Internal Medicine, State University of Campinas, School of Medical Sciences, Campinas, Sao Paulo, BrazilAbstract: The morbidity and mortality of pulmonary embolism (PE have been found to be related to early diagnosis and appropriate treatment. The examinations used to diagnose PE are expensive and not always easily accessible. These options include noninvasive examinations, such as clinical pretests, ELISA D-dimer (DD tests, and volumetric capnography (VCap. We report the case of a patient whose diagnosis of PE was made via pulmonary arteriography. The clinical pretest revealed a moderate probability of the patient having PE, and the DD result was negative; however, the VCap associated with arterial blood gases result was positive. The patient underwent all noninvasive exams following admission to hospital and again eight months after discharge. Results gained from invasive tests were similar to those produced by image exams, highlighting the importance of VCap as an important noninvasive tool.Keywords: pulmonary embolism, pulmonary hypertension, volumetric capnography, d-dimers, pretest probability

  20. Cerebrospinal fluid volumetric MRI mapping as a simple measurement for evaluating brain atrophy

    Energy Technology Data Exchange (ETDEWEB)

    Vis, J.B. de; Zwanenburg, J.J.; Kleij, L.A. van der; Spijkerman, J.M.; Hendrikse, J. [University Medical Center Utrecht, Department of Radiology, Utrecht (Netherlands); Biessels, G.J. [University Medical Center Utrecht, Department of Neurology, Brain Center Rudolf Magnus, Utrecht (Netherlands); Petersen, E.T. [University Medical Center Utrecht, Department of Radiology, Utrecht (Netherlands); Hvidovre Hospital, Danish Research Centre for Magnetic Resonance, Hvidovre (Denmark)

    2016-05-15

    To assess whether volumetric cerebrospinal fluid (CSF) MRI can be used as a surrogate for brain atrophy assessment and to evaluate how the T{sub 2} of the CSF relates to brain atrophy. Twenty-eight subjects [mean age 64 (sd 2) years] were included; T{sub 1}-weighted and CSF MRI were performed. The first echo data of the CSF MRI sequence was used to obtain intracranial volume, CSF partial volume was measured voxel-wise to obtain CSF volume (V{sub CSF}) and the T{sub 2} of CSF (T{sub 2,CSF}) was calculated. The correlation between V{sub CSF} / T{sub 2,CSF} and brain atrophy scores [global cortical atrophy (GCA) and medial temporal lobe atrophy (MTA)] was evaluated. Relative total, peripheral subarachnoidal, and ventricular V{sub CSF} increased significantly with increased scores on the GCA and MTA (R = 0.83, 0.78 and 0.78 and R = 0.72, 0.62 and 0.86). Total, peripheral subarachnoidal, and ventricular T{sub 2} of the CSF increased significantly with higher scores on the GCA and MTA (R = 0.72, 0.70 and 0.49 and R = 0.60, 0.57 and 0.41). A fast, fully automated CSF MRI volumetric sequence is an alternative for qualitative atrophy scales. The T{sub 2} of the CSF is related to brain atrophy and could thus be a marker of neurodegenerative disease. (orig.)