WorldWideScience

Sample records for volumes source measurements

  1. Volume and Surface-Enhanced Volume Negative Ion Sources

    International Nuclear Information System (INIS)

    Stockli, M P

    2013-01-01

    H - volume sources and, especially, caesiated H - volume sources are important ion sources for generating high-intensity proton beams, which then in turn generate large quantities of other particles. This chapter discusses the physics and technology of the volume production and the caesium-enhanced (surface) production of H - ions. Starting with Bacal's discovery of the H - volume production, the chapter briefly recounts the development of some H - sources, which capitalized on this process to significantly increase the production of H - beams. Another significant increase was achieved in the 1990s by adding caesiated surfaces to supplement the volume-produced ions with surface-produced ions, as illustrated with other H - sources. Finally, the focus turns to some of the experience gained when such a source was successfully ramped up in H - output and in duty factor to support the generation of 1 MW proton beams for the Spallation Neutron Source. (author)

  2. Development of production methods of volume source by the resinous solution which has hardening

    CERN Document Server

    Motoki, R

    2002-01-01

    Volume sources is used for standard sources by radioactive measurement using Ge semiconductor detector of environmental sample, e.g. water, soil and etc. that require large volume. The commercial volume source used in measurement of the water sample is made of agar-agar, and that used in measurement of the soil sample is made of alumina powder. When the plastic receptacles of this two kinds of volume sources were damaged, the leakage contents cause contamination. Moreover, if hermetically sealing performance of volume source made of agar-agar fell, volume decrease due to an evaporation off moisture gives an error to radioactive measurement. Therefore, we developed the two type methods using unsaturated polyester resin, vinilester resin, their hardening agent and acrylicresin. The first type is due to dispersing the hydrochloric acid solution included the radioisotopes uniformly in each resin and hardening the resin. The second is due to dispersing the alumina powder absorbed the radioisotopes in each resin an...

  3. Vector velocity volume flow estimation: Sources of error and corrections applied for arteriovenous fistulas

    DEFF Research Database (Denmark)

    Jensen, Jonas; Olesen, Jacob Bjerring; Stuart, Matthias Bo

    2016-01-01

    radius. The error sources were also studied in vivo under realistic clinical conditions, and the theoretical results were applied for correcting the volume flow errors. Twenty dialysis patients with arteriovenous fistulas were scanned to obtain vector flow maps of fistulas. When fitting an ellipsis......A method for vector velocity volume flow estimation is presented, along with an investigation of its sources of error and correction of actual volume flow measurements. Volume flow errors are quantified theoretically by numerical modeling, through flow phantom measurements, and studied in vivo...

  4. BNL volume H- source

    International Nuclear Information System (INIS)

    Prelec, K.; Alessi, J.G.

    1991-01-01

    The volume H minus ion source under development at Brookhaven is unique in that it has a toroidal plasma region, which feeds ions into the central extraction region through a conically shaped filter field. In pulsed operation, it produced 25 mA of H minus in a 1 cm 2 aperture, with an electron-to-H minus ratio of ∼ 3. At 19 mA, a normalized, 90% emittance of 0.44 π mm-mrad has been measured. Up to 50 mA has been extracted through a 1.87 cm 2 aperture. Although not designed for steady state operation, up to 6 mA has been extracted d.c. The addition of xenon to the discharge was found to improve the source output by 20--70%. The circular magnetic cusp field geometry was found to be more favorable than radial cusp fields. 4 refs., 5 figs

  5. Microflown based monopole sound sources for reciprocal measurements

    NARCIS (Netherlands)

    Bree, H.E. de; Basten, T.G.H.

    2008-01-01

    Monopole sound sources (i.e. omni directional sound sources with a known volume velocity) are essential for reciprocal measurements used in vehicle interior panel noise contribution analysis. Until recently, these monopole sound sources use a sound pressure transducer sensor as a reference sensor. A

  6. National comparison on volume sample activity measurement methods

    International Nuclear Information System (INIS)

    Sahagia, M.; Grigorescu, E.L.; Popescu, C.; Razdolescu, C.

    1992-01-01

    A national comparison on volume sample activity measurements methods may be regarded as a step toward accomplishing the traceability of the environmental and food chain activity measurements to national standards. For this purpose, the Radionuclide Metrology Laboratory has distributed 137 Cs and 134 Cs water-equivalent solid standard sources to 24 laboratories having responsibilities in this matter. Every laboratory has to measure the activity of the received source(s) by using its own standards, equipment and methods and report the obtained results to the organizer. The 'measured activities' will be compared with the 'true activities'. A final report will be issued, which plans to evaluate the national level of precision of such measurements and give some suggestions for improvement. (Author)

  7. EUV source development for high-volume chip manufacturing tools

    Science.gov (United States)

    Stamm, Uwe; Yoshioka, Masaki; Kleinschmidt, Jürgen; Ziener, Christian; Schriever, Guido; Schürmann, Max C.; Hergenhan, Guido; Borisov, Vladimir M.

    2007-03-01

    Xenon-fueled gas discharge produced plasma (DPP) sources were integrated into Micro Exposure Tools already in 2004. Operation of these tools in a research environment gave early learning for the development of EUV sources for Alpha and Beta-Tools. Further experiments with these sources were performed for basic understanding on EUV source technology and limits, especially the achievable power and reliability. The intermediate focus power of Alpha-Tool sources under development is measured to values above 10 W. Debris mitigation schemes were successfully integrated into the sources leading to reasonable collector mirror lifetimes with target of 10 billion pulses due to the effective debris flux reduction. Source collector mirrors, which withstand the radiation and temperature load of Xenon-fueled sources, have been developed in cooperation with MediaLario Technologies to support intermediate focus power well above 10 W. To fulfill the requirements for High Volume chip Manufacturing (HVM) applications, a new concept for HVM EUV sources with higher efficiency has been developed at XTREME technologies. The discharge produced plasma (DPP) source concept combines the use of rotating disk electrodes (RDE) with laser exited droplet targets. The source concept is called laser assisted droplet RDE source. The fuel of these sources has been selected to be Tin. The conversion efficiency achieved with the laser assisted droplet RDE source is 2-3x higher compared to Xenon. Very high pulse energies well above 200 mJ / 2π sr have been measured with first prototypes of the laser assisted droplet RDE source. If it is possible to maintain these high pulse energies at higher repetition rates a 10 kHz EUV source could deliver 2000 W / 2π sr. According to the first experimental data the new concept is expected to be scalable to an intermediate focus power on the 300 W level.

  8. A new mini-extrapolation chamber for beta source uniformity measurements

    International Nuclear Information System (INIS)

    Oliveira, M.L.; Caldas, L.V.E.

    2006-01-01

    According to recent international recommendations, beta particle sources should be specified in terms of absorbed dose rates to water at the reference point. However, because of the clinical use of these sources, additional information should be supplied in the calibration reports. This additional information include the source uniformity. A new small volume extrapolation chamber was designed and constructed at the Calibration Laboratory at Instituto de Pesquisas Energeticas e Nucleares, IPEN, Brazil, for the calibration of 90 Sr+ 90 Y ophthalmic plaques. This chamber can be used as a primary standard for the calibration of this type of source. Recent additional studies showed the feasibility of the utilization of this chamber to perform source uniformity measurements. Because of the small effective electrode area, it is possible to perform independent measurements by varying the chamber position by small steps. The aim of the present work was to study the uniformity of a 90 Sr+ 90 Y plane ophthalmic plaque utilizing the mini extrapolation chamber developed at IPEN. The uniformity measurements were performed by varying the chamber position by steps of 2 mm in the source central axis (x-and y-directions) and by varying the chamber position off-axis by 3 mm steps. The results obtained showed that this small volume chamber can be used for this purpose with a great advantage: it is a direct method, being unnecessary a previously calibration of the measurement device in relation to a reference instrument, and it provides real -time results, reducing the time necessary for the study and the determination of the uncertainties related to the measurements. (authors)

  9. Characterization of Greater-Than-Class C sealed sources. Volume 3, Sealed sources held by general licensees

    International Nuclear Information System (INIS)

    Harris, G.

    1994-09-01

    This is the third volume in a series of three volumes characterizing the population of sealed sources that may become greater-than-Class C low-level radioactive waste (GTCC LLW). In this volume, those sources possessed by general licensees are discussed. General-licensed devices may contain sealed sources with significant amounts of radioactive material. However, the devices are designed to be safe to use without special knowledge of radiological safety practices. Devices containing Am-241 or Cm-244 sources are most likely to become GTCC LLW after concentration averaging. This study estimates that there are about 16,000 GTCC devices held by general licensees; 15,000 of these contain Am-241 sources and 1,000 contain Cm-244 sources. Additionally, this study estimates that there are 1,600 GTCC devices sold to general licensees each year. However, due to a lack of available information on general licensees in Agreement States, these estimates are uncertain. This uncertainty is quantified in the low and high case estimates given in this report, which span approximately an order of magnitude

  10. Lung volumes: measurement, clinical use, and coding.

    Science.gov (United States)

    Flesch, Judd D; Dine, C Jessica

    2012-08-01

    Measurement of lung volumes is an integral part of complete pulmonary function testing. Some lung volumes can be measured during spirometry; however, measurement of the residual volume (RV), functional residual capacity (FRC), and total lung capacity (TLC) requires special techniques. FRC is typically measured by one of three methods. Body plethysmography uses Boyle's Law to determine lung volumes, whereas inert gas dilution and nitrogen washout use dilution properties of gases. After determination of FRC, expiratory reserve volume and inspiratory vital capacity are measured, which allows the calculation of the RV and TLC. Lung volumes are commonly used for the diagnosis of restriction. In obstructive lung disease, they are used to assess for hyperinflation. Changes in lung volumes can also be seen in a number of other clinical conditions. Reimbursement for measurement of lung volumes requires knowledge of current procedural terminology (CPT) codes, relevant indications, and an appropriate level of physician supervision. Because of recent efforts to eliminate payment inefficiencies, the 10 previous CPT codes for lung volumes, airway resistance, and diffusing capacity have been bundled into four new CPT codes.

  11. Accuracy and Sources of Error for an Angle Independent Volume Flow Estimator

    DEFF Research Database (Denmark)

    Jensen, Jonas; Olesen, Jacob Bjerring; Hansen, Peter Møller

    2014-01-01

    This paper investigates sources of error for a vector velocity volume flow estimator. Quantification of the estima tor’s accuracy is performed theoretically and investigated in vivo . Womersley’s model for pulsatile flow is used to simulate velo city profiles and calculate volume flow errors....... A BK Medical UltraView 800 ultrasound scanner with a 9 MHz linear array transducer is used to obtain Vector Flow Imaging sequences of a superficial part of the fistulas. Cross-sectional diameters of each fistu la are measured on B-mode images by rotating the scan plane 90 degrees. The major axis...

  12. Volume and mass measurements of liquids

    International Nuclear Information System (INIS)

    Zander, M.

    1987-12-01

    The report comprises the 10 lectures given at the 74th PTB seminar, which represent the state of the art in the field of liquid flow measurement. The lectures deal with the overflow-pipette as the primary volume standard of PTB, gas elimination devices (compulsory in measuring assemblies with volume meters), measuring assemblies for the reception of milk, electromagnetic flowmeters, vortex-shedding meters, indirect mass measurement from volume and density, direct mass measurement (coriolis flowmeters), pipeline-measurements, level measurement at storage tanks with conventional and optical methods and a development aid project for the set up of test rigs in India. (orig.) [de

  13. Determination of disintegration rates of a 60Co point source and volume sources by the sum-peak method

    International Nuclear Information System (INIS)

    Kawano, Takao; Ebihara, Hiroshi

    1990-01-01

    The disintegration rates of 60 Co as a point source (<2 mm in diameter on a thin plastic disc) and volume sources (10-100 mL solutions in a polyethylene bottle) are determined by the sum-peak method. The sum-peak formula gives the exact disintegration rate for the point source at different positions from the detector. However, increasing the volume of the solution results in enlarged deviations from the true disintegration rate. Extended sources must be treated as an amalgam of many point sources. (author)

  14. Dynamic evolution of the source volumes of gradual and impulsive solar flare emissions

    Science.gov (United States)

    Bruner, M. E.; Crannell, C. J.; Goetz, F.; Magun, A.; Mckenzie, D. L.

    1988-01-01

    This study compares flare source volumes inferred from impulsive hard X-rays and microwaves with those derived from density sensitive soft X-ray line ratios in the O VII spectrum. The data for this study were obtained with the SMM Hard X-ray Burst Spectrometer, Earth-based radio observatories, and the SOLEX-B spectrometer on the P78-1 satellite. Data were available for the flares of 1980 April 8, 1980 May 9, and 1981 February 26. The hard X-ray/microwave source volume is determined under the assumption that the same electron temperature or power law index characterizes both the source of hard X-rays and the source of microwaves. The O VII line ratios yield the density and volume of the 2 x 10 to the 6th K plasma. For all three flares, the O VII source volume is found to be smallest at the beginning of the flare, near the time when the impulsive hard X-ray/microwave volume reaches its first maximum. At this time, the O VII volume is three to four orders of magnitude smaller than that inferred from the hard X-ray/microwave analysis. Subsequently, the O VII source volume increases by one or two orders of magnitude then remains almost constant until the end of the flare when it apparently increases again.

  15. Dynamic evolution of the source volumes of gradual and impulsive solar flare emissions

    International Nuclear Information System (INIS)

    Bruner, M.E.; Crannell, C.J.; Goetz, F.; Magun, A.; Mckenzie, D.L.

    1987-12-01

    This study compares flare source volumes inferred from impulsive hard x rays and microwaves with those derived from density sensitive soft x ray line ratios in the O VII spectrum. The data for this study were obtained with the SMM Hard X-Ray Burst Spectrometer, Earth-based radio observatories, and the SOLEX-B spectrometer on the P78-1 satellite. Data were available for the flares of 1980 April 8, 1980 May 9, and 1981 February 26. The hard x ray/microwave source volume is determined under the assumption that the same electron temperature or power law index characterizes both the source of hard x rays and the source of microwaves. The O VII line ratios yield the density and volume of the 2 X 10 to the 6th K plasma. For all three flares, the O VII source volume is found to be smallest at the beginning of the flare, near the time when the impulsive hard x ray/microwave volume reaches its first maximum. At this time, the O VII volume is three to four orders of magnitude smaller than that inferred from the hard x ray/microwave analysis. Subsequently, the O VII source volume increases by one or two orders of magnitude then remains almost constant until the end of the flare when it apparently increases again

  16. Dynamic evolution of the source volumes of gradual and impulsive solar flare emissions

    International Nuclear Information System (INIS)

    Bruner, M.E.; Crannell, C.J.; Goetz, F.; Magun, A.; Mckenzie, D.L.

    1988-01-01

    This study compares flare source volumes inferred from impulsive hard X-rays and microwaves with those derived from density sensitive soft X-ray line ratios in the O VII spectrum. The data for this study were obtained with the SMM Hard X-ray Burst Spectrometer, Earth-based radio observatories, and the SOLEX-B spectrometer on the P78-1 satellite. Data were available for the flares of 1980 April 8, 1980 May 9, and 1981 February 26. The hard X-ray/microwave source volume is determined under the assumption that the same electron temperature or power law index characterizes both the source of hard X-rays and the source of microwaves. The O VII line ratios yield the density and volume of the 2 x 10 to the 6th K plasma. For all three flares, the O VII source volume is found to be smallest at the beginning of the flare, near the time when the impulsive hard X-ray/microwave volume reaches its first maximum. At this time, the O VII volume is three to four orders of magnitude smaller than that inferred from the hard X-ray/microwave analysis. Subsequently, the O VII source volume increases by one or two orders of magnitude then remains almost constant until the end of the flare when it apparently increases again. 29 references

  17. Radon measurements: the sources of uncertainties

    International Nuclear Information System (INIS)

    Zhukovsky, Michael; Onischenko, Alexandra; Bastrikov, Vladislav

    2008-01-01

    uncertainties for retrospective measurements conducted by surface traps techniques can be divided in two groups: errors of surface 210 Pb ( 210 Po) activity measurements and uncertainties of transfer from 210 Pb surface activity in glass objects to average radon concentration during this object exposure. The sources of 210 Pb ( 210 Po) surface activity measurement uncertainties are: errors in the calibration of energy-angle dependence of alpha-particles registration efficiency; random Poisson errors during measurements, the influence of background alpha radiation from the glass; unknown U-Ra-Th activity ratio in the glass, nonuniform 210 Po distribution on the surface of glass object. Uncertainty factors of Jacobi model for connection of 210 Pb surface activity and average radon concentration are: unknown aerosol concentration, ventilation rate, surface/volume ratio in investigated room, long term radon variations, aerosol deposition rates and errors in the age estimation of glass object. It is shown that total measurement error of surface trap retrospective technique can be decreased to 35%. The analysis of errors for grab sampling measurements, charcoal canisters and track detectors are presented in the full paper

  18. Dosimetric measurements of an 192Ir HDR source with a diamond detector

    International Nuclear Information System (INIS)

    Rustgi, Surendra N.

    1996-01-01

    Purpose: To study the feasibility of using a diamond detector for the dosimetry of a high dose rate (HDR) 192 Ir source and to compare the measurement results with published data and calculations from a commercial treatment planning system. Materials and methods: The sensitive volume of the diamond detector consists of a disk of 0.26 mm thickness and 3 mm diameter. The detector was applied an external bias of +100 V and was preirradiated to a dose of 500 cGy to stabilize its response. The 192 Ir source from the Nucletron microSelectron unit has an active diameter of 0.6 mm and a length of 3.5 mm. Photon fluence anisotropy factors in air were measured at distances of 5 and 10 cm from two sources and compared with TLD measurements. Dose profiles and isodose distributions were measured at several distances from the source and compared with calculations from a Nucletron treatment planning system. These dose calculations in water use a point source approximation with the anisotropy factors independent of the radial distance from the source. Results: The photon fluence around the 192 Ir HDR source, measured with a diamond detector at distances of 5 and 10 cm from the source, is very anisotropic. Compared to the source transverse direction, the photon fluence intensity along the source axis reduces to approximately 60%. Measurements performed on two sources indicate that the photon anisotropy does not change with distance in air. Within experimental uncertainty, similar results were obtained with TLD rods and are in excellent agreement with published anisotropy factors 1 . Dose profiles, measured with the diamond detector in a water phantom, at distances of 1,2,3 and 5 cm from the source, are found to be in excellent agreement with the Nucletron planning system calculations. Similar excellent agreement is observed between the measured and calculated isodose curves in planes parallel to the source plane. Conclusion: The diamond detector has been demonstrated to be suitable

  19. SU-E-I-79: Source Geometry Dependence of Gamma Well-Counter Measurements

    Energy Technology Data Exchange (ETDEWEB)

    Park, M; Belanger, A; Kijewski, M [Brigham and Women’s Hospital and Harvard Medical School, Boston, MA (United States)

    2015-06-15

    Purpose: To determine the effect of liquid sample volume and geometry on counting efficiency in a gamma well-counter, and to assess the relative contributions of sample geometry and self-attenuation. Gamma wellcounters are standard equipment in clinical and preclinical studies, for measuring patient blood radioactivity and quantifying animal tissue uptake for tracer development and other purposes. Accurate measurements are crucial. Methods: Count rates were measured for aqueous solutions of 99m- Tc at four liquid volume values in a 1-cm-diam tube and at six volume values in a 2.2-cm-diam vial. Total activity was constant for all volumes, and data were corrected for decay. Count rates from a point source in air, supported by a filter paper, were measured at seven heights between 1.3 and 5.7 cm from the bottom of a tube. Results: Sample volume effects were larger for the tube than for the vial. For the tube, count efficiency relative to a 1-cc volume ranged from 1.05 at 0.05 cc to 0.84 at 3 cc. For the vial, relative count efficiency ranged from 1.02 at 0.05 cc to 0.87 at 15 cc. For the point source, count efficiency relative to 1.3 cm from the tube bottom ranged from 0.98 at 1.8 cm to 0.34 at 5.7 cm. The relative efficiency of a 3-cc liquid sample in a tube compared to a 1-cc sample is 0.84; the average relative efficiency for the solid sample in air between heights in the tube corresponding to the surfaces of those volumes (1.3 and 4.8 cm) is 0.81, implying that the major contribution to efficiency loss is geometry, rather than attenuation. Conclusion: Volume-dependent correction factors should be used for accurate quantitation radioactive of liquid samples. Solid samples should be positioned at the bottom of the tube for maximum count efficiency.

  20. Design parameters and source terms: Volume 2, Source terms: Revision 0

    International Nuclear Information System (INIS)

    1987-09-01

    The Design Parameters and Source Terms Document was prepared in accordance with DOE request and to provide data for the environmental impact study to be performed in the future for the Deaf Smith County, Texas site for a nuclear waste repository in salt. This document updates a previous unpublished report to the level of the Site Characterization Plan---Conceptual Design Report SCP-CDR. The previous study identifies the data needs for the Environmental Assessment effort for seven possible salt repository sites. Volume 2 contains tables of source terms

  1. VOLUMNECT: measuring volumes with Kinect

    Science.gov (United States)

    Quintino Ferreira, Beatriz; Griné, Miguel; Gameiro, Duarte; Costeira, João. Paulo; Sousa Santos, Beatriz

    2014-03-01

    This article presents a solution to volume measurement object packing using 3D cameras (such as the Microsoft KinectTM). We target application scenarios, such as warehouses or distribution and logistics companies, where it is important to promptly compute package volumes, yet high accuracy is not pivotal. Our application auto- matically detects cuboid objects using the depth camera data and computes their volume and sorting it allowing space optimization. The proposed methodology applies to a point cloud simple computer vision and image processing methods, as connected components, morphological operations and Harris corner detector, producing encouraging results, namely an accuracy in volume measurement of 8mm. Aspects that can be further improved are identified; nevertheless, the current solution is already promising turning out to be cost effective for the envisaged scenarios.

  2. Test of Effective Solid Angle code for the efficiency calculation of volume source

    Energy Technology Data Exchange (ETDEWEB)

    Kang, M. Y.; Kim, J. H.; Choi, H. D. [Seoul National Univ., Seoul (Korea, Republic of); Sun, G. M. [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2013-10-15

    It is hard to determine a full energy (FE) absorption peak efficiency curve for an arbitrary volume source by experiment. That's why the simulation and semi-empirical methods have been preferred so far, and many works have progressed in various ways. Moens et al. determined the concept of effective solid angle by considering an attenuation effect of γ-rays in source, media and detector. This concept is based on a semi-empirical method. An Effective Solid Angle code (ESA code) has been developed for years by the Applied Nuclear Physics Group in Seoul National University. ESA code converts an experimental FE efficiency curve determined by using a standard point source to that for a volume source. To test the performance of ESA Code, we measured the point standard sources and voluminous certified reference material (CRM) sources of γ-ray, and compared with efficiency curves obtained in this study. 200∼1500 KeV energy region is fitted well. NIST X-ray mass attenuation coefficient data is used currently to check for the effect of linear attenuation only. We will use the interaction cross-section data obtained from XCOM code to check the each contributing factor like photoelectric effect, incoherent scattering and coherent scattering in the future. In order to minimize the calculation time and code simplification, optimization of algorithm is needed.

  3. Chemical Method of Urine Volume Measurement

    Science.gov (United States)

    Petrack, P.

    1967-01-01

    A system has been developed and qualified as flight hardware for the measurement of micturition volumes voided by crewmen during Gemini missions. This Chemical Urine Volume Measurement System (CUVMS) is used for obtaining samples of each micturition for post-flight volume determination and laboratory analysis for chemical constituents of physiological interest. The system is versatile with respect to volumes measured, with a capacity beyond the largest micturition expected to be encountered, and with respect to mission duration of inherently indefinite length. The urine sample is used for the measurement of total micturition volume by a tracer dilution technique, in which a fixed, predetermined amount of tritiated water is introduced and mixed into the voided urine, and the resulting concentration of the tracer in the sample is determined with a liquid scintillation spectrometer. The tracer employed does not interfere with the analysis for the chemical constituents of the urine. The CUVMS hardware consists of a four-way selector valve in which an automatically operated tracer metering pump is incorporated, a collection/mixing bag, and tracer storage accumulators. The assembled system interfaces with a urine receiver at the selector valve inlet, sample bags which connect to the side of the selector valve, and a flexible hose which carries the excess urine to the overboard drain connection. Results of testing have demonstrated system volume measurement accuracy within the specification limits of +/-5%, and operating reliability suitable for system use aboard the GT-7 mission, in which it was first used.

  4. The peak efficiency calibration of volume source using 152Eu point source in computer

    International Nuclear Information System (INIS)

    Shen Tingyun; Qian Jianfu; Nan Qinliang; Zhou Yanguo

    1997-01-01

    The author describes the method of the peak efficiency calibration of volume source by means of 152 Eu point source for HPGe γ spectrometer. The peak efficiency can be computed by Monte Carlo simulation, after inputting parameter of detector. The computation results are in agreement with the experimental results with an error of +-3.8%, with an exception one is about +-7.4%

  5. Calibration of Ge(Li) semiconductor detector by method using agar volume source

    International Nuclear Information System (INIS)

    Yanase, Nobuyuki; Kasai, Atsushi

    1979-12-01

    The Ge(Li) semiconductor detector was calibrated for measurements of environmental samples. The radioisotopes used for standard sources are 22 Na, 51 Cr, 56 Co, 57 Co, 133 Ba, 137 Cs, 144 Ce and 241 Am. These are mixed with hot agar aqueous solution and fixed uniformly in a cylindrical plastic case in cooling. The agar volume source is advantageous in handling over the fluid aqueous source. The prepared cylindrical standard sources are in diameters 6 and 8 cm and thicknesses 1, 5, 10, 20, 30 and 40 mm (only for 8 cm diameter). The radioactivities of prepared standard sources are between 0.03 μCi and 0.2 μCi. It takes only a week to make the calibration except data processing. The obtained full energy peak efficiency curves include 5 - 10% error due to preparation of agar source, reference radioactivity data of purchased standard solutions, reference data of branching ratio of gamma-ray and sum effect. The efficiency curves, however, are sufficient for quantitative analysis of environmental samples. (author)

  6. Enhancement of H{sup -}/D{sup -} volume production in a double plasma type negative ion source

    Energy Technology Data Exchange (ETDEWEB)

    Fukumasa, Osamu; Nishimura, Hideki; Sakiyama, Satoshi [Yamaguchi Univ., Ube (Japan). Faculty of Engineering

    1997-02-01

    H{sup -}/D{sup -} production in a pure volume source has been studied. In our double plasma type negative ion source, both energy and density of fast electrons are well controlled. With the use of this source, the enhancement of H{sup -}/D{sup -} production has been observed. Namely, under the same discharge power, the extracted H{sup -}/D{sup -} current in the double plasma operation is higher than that in the single plasma operation. At the same time, measurements of plasma parameters have been made in the source and the extractor regions for these two cases. (author)

  7. MRI volume measurement of basal ganglia volumes in patients with Tourette's syndrome

    International Nuclear Information System (INIS)

    Lu Jie; Li Kuncheng; Cao Yanxiang; Zhang Miao; Sui Xin; Zhang Xiaohua

    2009-01-01

    Objective: To evaluate MRI measurement of basal ganglia volumes in patients with Tourette's syndrome. Methods: Ten patients with Tourette's syndrome (TS) and 10 healthy volunteers were studied. Volumes of bilateral caudate, putamen and pallidum were measured, and the results were analyzed using paired t test. The basal ganglia volume was normalized according to individual brain volume. The basal ganglia volumes of TS patients were compared with normal control group using independent-sample t test. Results: In 10 healthy volunteers, volumes of the left caudate, putamen, pallidum were significantly larger compared with those of the right side (P 0.05) in TS patients. After normalized processing, the volumes of the left caudate (7.06 ± 0.48) cm 3 , putamen (8.81±1.01) cm 3 , pallidum (2.64± 0.38) cm 3 were smaller than those of control group [caudate (11.05±1.86) cm 3 , putamen (9.97± 1.11) cm 3 , pallidum (3.04±0.37) cm 3 ] (t=-6.577, -2.457, -2.376, P 3 in TS patients was significantly smaller compared with the control group (9.81±1.83) cm 3 (t=-4.258, P 0.05). Conclusion: The basal ganglia volumes were significantly decreased in patients with TS. MRI volumetric measurement was an important tool for evaluating pathologic changes of TS. (authors)

  8. Measurement of Atmospheric Neutrino Oscillations with Very Large Volume Neutrino Telescopes

    Directory of Open Access Journals (Sweden)

    J. P. Yáñez

    2015-01-01

    Full Text Available Neutrino oscillations have been probed during the last few decades using multiple neutrino sources and experimental set-ups. In the recent years, very large volume neutrino telescopes have started contributing to the field. First ANTARES and then IceCube have relied on large and sparsely instrumented volumes to observe atmospheric neutrinos for combinations of baselines and energies inaccessible to other experiments. Using this advantage, the latest result from IceCube starts approaching the precision of other established technologies and is paving the way for future detectors, such as ORCA and PINGU. These new projects seek to provide better measurements of neutrino oscillation parameters and eventually determine the neutrino mass ordering. The results from running experiments and the potential from proposed projects are discussed in this review, emphasizing the experimental challenges involved in the measurements.

  9. Cerebrospinal fluid volume measurements in hydrocephalic rats.

    Science.gov (United States)

    Basati, Sukhraaj; Desai, Bhargav; Alaraj, Ali; Charbel, Fady; Linninger, Andreas

    2012-10-01

    Object Experimental data about the evolution of intracranial volume and pressure in cases of hydrocephalus are limited due to the lack of available monitoring techniques. In this study, the authors validate intracranial CSF volume measurements within the lateral ventricle, while simultaneously using impedance sensors and pressure transducers in hydrocephalic animals. Methods A volume sensor was fabricated and connected to a catheter that was used as a shunt to withdraw CSF. In vitro bench-top calibration experiments were created to provide data for the animal experiments and to validate the sensors. To validate the measurement technique in a physiological system, hydrocephalus was induced in weanling rats by kaolin injection into the cisterna magna. At 28 days after induction, the sensor was implanted into the lateral ventricles. After sealing the skull using dental cement, an acute CSF drainage/infusion protocol consisting of 4 sequential phases was performed with a pump. Implant location was confirmed via radiography using intraventricular iohexol contrast administration. Results Controlled CSF shunting in vivo with hydrocephalic rats resulted in precise and accurate sensor measurements (r = 0.98). Shunting resulted in a 17.3% maximum measurement error between measured volume and actual volume as assessed by a Bland-Altman plot. A secondary outcome confirmed that both ventricular volume and intracranial pressure decreased during CSF shunting and increased during infusion. Ventricular enlargement consistent with successful hydrocephalus induction was confirmed using imaging, as well as postmortem. These results indicate that volume monitoring is feasible for clinical cases of hydrocephalus. Conclusions This work marks a departure from traditional shunting systems currently used to treat hydrocephalus. The overall clinical application is to provide alternative monitoring and treatment options for patients. Future work includes development and testing of a chronic

  10. Brain volume measurement using three-dimensional magnetic resonance images

    International Nuclear Information System (INIS)

    Ishimaru, Yoshihiro

    1996-01-01

    This study was designed to validate accurate measurement method of human brain volume using three dimensional (3D) MRI data on a workstation, and to establish optimal correcting method of human brain volume on diagnosis of brain atrophy. 3D MRI data were acquired by fast SPGR sequence using 1.5 T MR imager. 3D MRI data were segmented by region growing method and 3D image was displayed by surface rendering method on the workstation. Brain volume was measured by the volume measurement function of the workstation. In order to validate the accurate measurement method, phantoms and a specimen of human brain were examined. Phantom volume was measured by changing the lower level of threshold value. At the appropriate threshold value, percentage of error of phantoms and the specimen were within 0.6% and 0.08%, respectively. To establish the optimal correcting method, 130 normal volunteers were examined. Brain volumes corrected with height weight, body surface area, and alternative skull volume were evaluated. Brain volume index, which is defined as dividing brain volume by alternative skull volume, had the best correlation with age (r=0.624, p<0.05). No gender differences was observed in brain volume index in contrast to in brain volume. The clinical usefulness of this correcting method for brain atrophy diagnosis was evaluated in 85 patients. Diagnosis by 2D spin echo MR images was compared with brain volume index. Diagnosis of brain atrophy by 2D MR image was concordant with the evaluation by brain volume index. These results indicated that this measurement method had high accuracy, and it was important to set the appropriate threshold value. Brain volume index was the appropriate indication for evaluation of human brain volume, and was considered to be useful for the diagnosis of brain atrophy. (author)

  11. Broadband frequency ECR ion source concepts with large resonant plasma volumes

    International Nuclear Information System (INIS)

    Alton, G.D.

    1995-01-01

    New techniques are proposed for enhancing the performances of ECR ion sources. The techniques are based on the use of high-power, variable-frequency, multiple-discrete-frequency, or broadband microwave radiation, derived from standard TWT technology, to effect large resonant ''volume'' ECR sources. The creation of a large ECR plasma ''volume'' permits coupling of more power into the plasma, resulting in the heating of a much larger electron population to higher energies, the effect of which is to produce higher charge state distributions and much higher intensities within a particular charge state than possible in present forms of the ECR ion source. If successful, these developments could significantly impact future accelerator designs and accelerator-based, heavy-ion-research programs by providing multiply-charged ion beams with the energies and intensities required for nuclear physics research from existing ECR ion sources. The methods described in this article can be used to retrofit any ECR ion source predicated on B-minimum plasma confinement techniques

  12. Cerebral blood volume measurement using radioactive carboxyhemoglobin and positron emission tomography. Chapter 26

    International Nuclear Information System (INIS)

    Kanno, Iwao; Murakami, Matsutaro; Miura, Shuichi; Iida, Hidehiro; Takahashi, Kazuhiro; Sasaki, Hiroshi; Uemura, Kazuo

    1988-01-01

    This paper aims to describe the technical basis for this simplest cerebral blood volume (CBV) measurement using CO-labelled red blood cells and PET and to clarify the error sources in the technique which will become critical when we perform studies on physiological activation of CBV. 17 refs.; 6 figs.; 2 tabs

  13. Measurement of disintegration rates of 60Co volume sources by the sum-peak method

    International Nuclear Information System (INIS)

    Kawano, Takao; Ebihara, Hiroshi

    1991-01-01

    The sum-peak method has been applied to the determination of the disintegration rates of 60 Co volume sources (1.05 x 10 4 Bq, 1.05 x 10 3 Bq and 1.05 x 10 2 Bq, in 100-ml polyethylene bottles) by using a NaI(Tl) detector of a diameter of 50 mm and a height of 50 mm. The experimental results showed that decreasing the disintegration rates resulted in enlarged underestimation in comparison with the true disintegration rates. It was presumed that the underestimations of the disintegration rates determined by the sum-peak method resulted from the overestimations of the areas under the sum peaks caused by the overlap of the area under the Compton scattering of the γ-ray (2614 keV) emitted from a naturally occurring radionuclide 208 Tl under the sum peaks. (author)

  14. Determination of air-loop volume and radon partition coefficient for measuring radon in water sample.

    Science.gov (United States)

    Lee, Kil Yong; Burnett, William C

    A simple method for the direct determination of the air-loop volume in a RAD7 system as well as the radon partition coefficient was developed allowing for an accurate measurement of the radon activity in any type of water. The air-loop volume may be measured directly using an external radon source and an empty bottle with a precisely measured volume. The partition coefficient and activity of radon in the water sample may then be determined via the RAD7 using the determined air-loop volume. Activity ratios instead of absolute activities were used to measure the air-loop volume and the radon partition coefficient. In order to verify this approach, we measured the radon partition coefficient in deionized water in the temperature range of 10-30 °C and compared the values to those calculated from the well-known Weigel equation. The results were within 5 % variance throughout the temperature range. We also applied the approach for measurement of the radon partition coefficient in synthetic saline water (0-75 ppt salinity) as well as tap water. The radon activity of the tap water sample was determined by this method as well as the standard RAD-H 2 O and BigBottle RAD-H 2 O. The results have shown good agreement between this method and the standard methods.

  15. Determination of air-loop volume and radon partition coefficient for measuring radon in water sample

    International Nuclear Information System (INIS)

    Kil Yong Lee; Burnett, W.C.

    2013-01-01

    A simple method for the direct determination of the air-loop volume in a RAD7 system as well as the radon partition coefficient was developed allowing for an accurate measurement of the radon activity in any type of water. The air-loop volume may be measured directly using an external radon source and an empty bottle with a precisely measured volume. The partition coefficient and activity of radon in the water sample may then be determined via the RAD7 using the determined air-loop volume. Activity ratios instead of absolute activities were used to measure the air-loop volume and the radon partition coefficient. In order to verify this approach, we measured the radon partition coefficient in deionized water in the temperature range of 10-30 deg C and compared the values to those calculated from the well-known Weigel equation. The results were within 5 % variance throughout the temperature range. We also applied the approach for measurement of the radon partition coefficient in synthetic saline water (0-75 ppt salinity) as well as tap water. The radon activity of the tap water sample was determined by this method as well as the standard RAD-H 2 O and BigBottle RAD-H 2 O. The results have shown good agreement between this method and the standard methods. (author)

  16. 21 CFR 876.1800 - Urine flow or volume measuring system.

    Science.gov (United States)

    2010-04-01

    ... volume measuring system. (a) Identification. A urine flow or volume measuring system is a device that measures directly or indirectly the volume or flow of urine from a patient, either during the course of... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Urine flow or volume measuring system. 876.1800...

  17. Volume-weighted measure for eternal inflation

    International Nuclear Information System (INIS)

    Winitzki, Sergei

    2008-01-01

    I propose a new volume-weighted probability measure for cosmological 'multiverse' scenarios involving eternal inflation. The 'reheating-volume (RV) cutoff' calculates the distribution of observable quantities on a portion of the reheating hypersurface that is conditioned to be finite. The RV measure is gauge-invariant, does not suffer from the 'youngness paradox', and is independent of initial conditions at the beginning of inflation. In slow-roll inflationary models with a scalar inflaton, the RV-regulated probability distributions can be obtained by solving nonlinear diffusion equations. I discuss possible applications of the new measure to 'landscape' scenarios with bubble nucleation. As an illustration, I compute the predictions of the RV measure in a simple toy landscape.

  18. Study on a volume-production H- ion source

    International Nuclear Information System (INIS)

    Takama, S.

    1988-01-01

    H - ions formed by volume-production are extracted from a multicuspion source. By applying a large positive bias to the plasma electrode, the ratio I - /I e becomes 1/20. H - ion current of 0.4mA is extracted from a 0.3cm 2 circular aperture at an arc current of 10A. (author)

  19. The BNL toroidal volume H- source

    International Nuclear Information System (INIS)

    Alessi, J.G.; Prelec, K.

    1991-01-01

    The BNL toroidal volume H - ion source, in pulsed operation is now producing up to 35 mA with an electron to H - ratio of less than 5, and a ratio of less than 3 for currents up to 20 mA. This improvement came about by increasing the strength of the conical filter field. The source has also been operated steady state at low arc currents, where up to 6 mA of H - was extracted. The electron to H - ratio is 2--3 times larger for dc operation. For dc currents up to 5 mA, the arc power efficiency was 5 mA/kW. Pulsed performance with Ta and W filaments were very similar, except for the large gas pumping observed with the Ta filament. In dc operation, the Ta filament performed somewhat better than W. Extraction from 7 apertures having a total area of 1 cm 2 produced the same results as a single 1 cm 2 aperture. 5 refs., 4 figs

  20. Atomic force microscopy imaging to measure precipitate volume fraction in nickel-based superalloys

    International Nuclear Information System (INIS)

    Bourhettar, A.; Troyon, M.; Hazotte, A.

    1995-01-01

    In nickel-based superalloys, quantitative analysis of scanning electron microscopy images fails in providing accurate microstructural data, whereas more efficient techniques are very time-consuming. As an alternative approach, the authors propose to perform quantitative analysis of atomic force microscopy images of polished/etched surfaces (quantitative microprofilometry). This permits the measurement of microstructural parameters and the depth of etching, which is the main source of measurement bias. Thus, nonbiased estimations can be obtained by extrapolation of the measurements up to zero etching depth. In this article, the authors used this approach to estimate the volume fraction of γ' precipitates in a nickel-based superalloy single crystal. Atomic force microscopy images of samples etched for different times show definition, homogeneity, and contrast high enough to perform image analysis. The result after extrapolation is in very good agreement with volume fraction values available from published reports

  1. Comments on H- volume production in Cs-seeded ion sources. Appendix I

    International Nuclear Information System (INIS)

    Peterson, J.R.

    1986-01-01

    Considerable interest was generated at the IAEA Negative Ion Beam Workshop in Grenoble, France, in March, 1985, by a report from the Kurchatov Institute on the development of a 2-ampere steady-state H - ion source, in which the ions were volume-produced in a discharge in H 2 , seeded with Cs vapor. The mechanism primarily responsible for this remarkably high current from a volume production source was not yet understood, but it was tentatively presumed to involve the collisional energy transfer from electronically excited Cs 6p atoms into H 2 vibrations. In any case, it was apparently different from the surface-plasma interactions that have been assumed to control the H - production in the Dudnikov-Dimov type sources

  2. Measurement of liver volume by emission computed tomography

    International Nuclear Information System (INIS)

    Kan, M.K.; Hopkins, G.B.

    1979-01-01

    In 22 volunteers without clinical or laboratory evidence of liver disease, liver volume was determined using single-photon emission computed tomography (ECT). This technique provided excellent object contrast between the liver and its surroundings and permitted calculation of liver volume without geometric assumptions about the liver's configuration. Reproducibility of results was satisfactory, with a root-mean-square error of less than 6% between duplicate measurements in 15 individuals. The volume measurements were validated by the use of phantoms

  3. Quantitation of mandibular symphysis volume as a source of bone grafting.

    Science.gov (United States)

    Verdugo, Fernando; Simonian, Krikor; Smith McDonald, Roberto; Nowzari, Hessam

    2010-06-01

    Autogenous intramembranous bone graft present several advantages such as minimal resorption and high concentration of bone morphogenetic proteins. A method for measuring the amount of bone that can be harvested from the symphysis area has not been reported in real patients. The aim of the present study was to intrasurgically quantitate the volume of the symphysis bone graft that can be safely harvested in live patients and compare it with AutoCAD (version 16.0, Autodesk, Inc., San Rafael, CA, USA) tomographic calculations. AutoCAD software program quantitated symphysis bone graft in 40 patients using computerized tomographies. Direct intrasurgical measurements were recorded thereafter and compared with AutoCAD data. The bone volume was measured at the recipient sites of a subgroup of 10 patients, 6 months post sinus augmentation. The volume of bone graft measured by AutoCAD averaged 1.4 mL (SD 0.6 mL, range: 0.5-2.7 mL). The volume of bone graft measured intrasurgically averaged 2.3 mL (SD 0.4 mL, range 1.7-2.8 mL). The statistical difference between the two measurement methods was significant. The bone volume measured at the recipient sites 6 months post sinus augmentation averaged 1.9 mL (SD 0.3 mL, range 1.3-2.6 mL) with a mean loss of 0.4 mL. AutoCAD did not overestimate the volume of bone that can be safely harvested from the mandibular symphysis. The use of the design software program may improve surgical treatment planning prior to sinus augmentation.

  4. Flow rate measurement in a volume

    Energy Technology Data Exchange (ETDEWEB)

    Galvez, Cristhian

    2018-04-17

    A system for measuring flow rate within a volume includes one or more transmission devices that transmit one or more signals through fluid contained within the volume. The volume may be bounded, at least in part, by an outer structure and by an object at least partially contained within the outer structure. A transmission device located at a first location of the outer structure transmits a first signal to a second location of the outer structure. A second signal is transmitted through the fluid from the second location to a third location of the outer structure. The flow rate of the fluid within the volume may be determined based, at least in part, on the time of flight of both the first signal and the second signal.

  5. Critical evaluation of blood volume measurements during hemodialysis.

    Science.gov (United States)

    Dasselaar, Judith J; van der Sande, Frank M; Franssen, Casper F M

    2012-01-01

    Devices that continuously measure relative blood volume (RBV) changes during hemodialysis (HD) are increasingly used for the prevention of dialysis hypotension and fine-tuning of dry weight. However, RBV measurements are subject to various limitations. First, RBV devices provide information on relative blood volume changes but not on absolute blood volume. Since blood volume varies with the hydration status, identical reductions of RBV may result in very different absolute blood volumes at the end of HD. Second, RBV changes underestimate the change of total blood volume due to translocation of lower-hematocrit blood from the microcirculation to the central circulation. Third, changes in posture before and during HD, food intake, exercise, and administration of intravenous fluids may influence the validity of the RBV measurement. Fourth, results obtained by various RBV devices show large interdevice differences. Finally, although a fall in blood volume is an important factor in dialysis hypotension, frank dialysis hypotension only occurs when the cardiovascular compensatory mechanisms can no longer compensate for the reduction in blood volume. Therefore, the dialysis staff should not exclusively focus on RBV, but also search for opportunities in the dialysis prescription to facilitate cardiovascular compensatory mechanisms, e.g. by lowering dialysate temperature. In the opinion of the authors, routine RBV monitoring should be used with caution until the major conceptual and methodological problems that are inherent to the indirect RBV estimation are clarified. Copyright © 2012 S. Karger AG, Basel.

  6. Comparison of bone volume measurements using conventional single and dual energy computed tomography

    International Nuclear Information System (INIS)

    Kim, Yung Kyoon; Park, Sang Hoon; Kim, Yon Min

    2017-01-01

    The study examines changes in calcium volume on born by comparing two figures; one is measured by dual energy computed tomography(DECT) followed by applying variation in monochromatic energy selection( keV), material decomposition(MD), and material suppressed iodine(MSI) analysis, and the other is measured by conventional single source computed tomography(CSCT). For this study, based on CSCT images taken by using human mimicked phantom, 70, 100, 140 keV and MSI, MD material calcium weighting( MCW) and MD material iodine weighting(MIW) of DECT were applied respectively. Then calculated calcium volume was converted to Agatston score for comparison. Volume of human mimicked phantom was in inverse proportion to keV. The volume decreased while keV increased(p<0.05). The most similar DECT volumes were reconstructed at 70 keV, the difference was showed 35.8±12.2 for rib, femur (16.1±24.1), pelvis(13.7±18.8), and spine(179.0±61.8). However, the volume of MSI was down for each organ; the volume of rib was 5.55%, femur(76.34%), pelvis(55.16%) and spine(87.58%). The volume of MSI decreased 55.9% for rib, femur(80.7%), pelvis(69.6%) and spine(54.2%) while MD MIW reduced for rib(83.51%), femur(87.68%), pelvis(86.64%), and spine(82.62%). With the results, the study found that outcomes were affected by the method which examiners employed. When using DECT, calcium volume of born dropped with keV increased. It also found that the most similar DECT images were reconstructed at 70 keV. The results of experiments implied that the users of MSI and MD should be cautious of errors as there are big differences in scores between those two methods

  7. Comparison of bone volume measurements using conventional single and dual energy computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Yung Kyoon; Park, Sang Hoon [Dept. of Radiology, Samsung Medical Center, Seoul (Korea, Republic of); Kim, Yon Min [Dept. of Radiotechnology, Wonkwang Health Science University, Iksan (Korea, Republic of)

    2017-06-15

    The study examines changes in calcium volume on born by comparing two figures; one is measured by dual energy computed tomography(DECT) followed by applying variation in monochromatic energy selection( keV), material decomposition(MD), and material suppressed iodine(MSI) analysis, and the other is measured by conventional single source computed tomography(CSCT). For this study, based on CSCT images taken by using human mimicked phantom, 70, 100, 140 keV and MSI, MD material calcium weighting( MCW) and MD material iodine weighting(MIW) of DECT were applied respectively. Then calculated calcium volume was converted to Agatston score for comparison. Volume of human mimicked phantom was in inverse proportion to keV. The volume decreased while keV increased(p<0.05). The most similar DECT volumes were reconstructed at 70 keV, the difference was showed 35.8±12.2 for rib, femur (16.1±24.1), pelvis(13.7±18.8), and spine(179.0±61.8). However, the volume of MSI was down for each organ; the volume of rib was 5.55%, femur(76.34%), pelvis(55.16%) and spine(87.58%). The volume of MSI decreased 55.9% for rib, femur(80.7%), pelvis(69.6%) and spine(54.2%) while MD MIW reduced for rib(83.51%), femur(87.68%), pelvis(86.64%), and spine(82.62%). With the results, the study found that outcomes were affected by the method which examiners employed. When using DECT, calcium volume of born dropped with keV increased. It also found that the most similar DECT images were reconstructed at 70 keV. The results of experiments implied that the users of MSI and MD should be cautious of errors as there are big differences in scores between those two methods.

  8. A Radon Chamber without Radium Source for Detector Calibration and Radon Measurements

    International Nuclear Information System (INIS)

    Al-Azmi, D.; Karunakara, N.

    2008-01-01

    A radon chamber of volume 216 liters was designed and constructed for calibration of radon detectors and radon test measurements. The main feature of this chamber is that the active 226 Ra source, to generate the 222 Rn inside the chamber volume, is not required. Instead, 222 Rn from soil gas is utilized for this purpose. The supply of radon comes from the soil gas. Soil gas is drawn from the soil to fill the chamber with high radon concentration levels (∼ 80 kBq/m3). Desired radon concentration levels can be obtained by drawing the soil gas for different time durations and/or flow rate (author)

  9. Numerical simulation of seismic wave propagation from land-excited large volume air-gun source

    Science.gov (United States)

    Cao, W.; Zhang, W.

    2017-12-01

    The land-excited large volume air-gun source can be used to study regional underground structures and to detect temporal velocity changes. The air-gun source is characterized by rich low frequency energy (from bubble oscillation, 2-8Hz) and high repeatability. It can be excited in rivers, reservoirs or man-made pool. Numerical simulation of the seismic wave propagation from the air-gun source helps to understand the energy partitioning and characteristics of the waveform records at stations. However, the effective energy recorded at a distance station is from the process of bubble oscillation, which can not be approximated by a single point source. We propose a method to simulate the seismic wave propagation from the land-excited large volume air-gun source by finite difference method. The process can be divided into three parts: bubble oscillation and source coupling, solid-fluid coupling and the propagation in the solid medium. For the first part, the wavelet of the bubble oscillation can be simulated by bubble model. We use wave injection method combining the bubble wavelet with elastic wave equation to achieve the source coupling. Then, the solid-fluid boundary condition is implemented along the water bottom. And the last part is the seismic wave propagation in the solid medium, which can be readily implemented by the finite difference method. Our method can get accuracy waveform of land-excited large volume air-gun source. Based on the above forward modeling technology, we analysis the effect of the excited P wave and the energy of converted S wave due to different water shapes. We study two land-excited large volume air-gun fields, one is Binchuan in Yunnan, and the other is Hutubi in Xinjiang. The station in Binchuan, Yunnan is located in a large irregular reservoir, the waveform records have a clear S wave. Nevertheless, the station in Hutubi, Xinjiang is located in a small man-made pool, the waveform records have very weak S wave. Better understanding of

  10. New simple method for fast and accurate measurement of volumes

    International Nuclear Information System (INIS)

    Frattolillo, Antonio

    2006-01-01

    A new simple method is presented, which allows us to measure in just a few minutes but with reasonable accuracy (less than 1%) the volume confined inside a generic enclosure, regardless of the complexity of its shape. The technique proposed also allows us to measure the volume of any portion of a complex manifold, including, for instance, pipes and pipe fittings, valves, gauge heads, and so on, without disassembling the manifold at all. To this purpose an airtight variable volume is used, whose volume adjustment can be precisely measured; it has an overall capacity larger than that of the unknown volume. Such a variable volume is initially filled with a suitable test gas (for instance, air) at a known pressure, as carefully measured by means of a high precision capacitive gauge. By opening a valve, the test gas is allowed to expand into the previously evacuated unknown volume. A feedback control loop reacts to the resulting finite pressure drop, thus contracting the variable volume until the pressure exactly retrieves its initial value. The overall reduction of the variable volume achieved at the end of this process gives a direct measurement of the unknown volume, and definitively gets rid of the problem of dead spaces. The method proposed actually does not require the test gas to be rigorously held at a constant temperature, thus resulting in a huge simplification as compared to complex arrangements commonly used in metrology (gas expansion method), which can grant extremely accurate measurement but requires rather expensive equipments and results in time consuming methods, being therefore impractical in most applications. A simple theoretical analysis of the thermodynamic cycle and the results of experimental tests are described, which demonstrate that, in spite of its simplicity, the method provides a measurement accuracy within 0.5%. The system requires just a few minutes to complete a single measurement, and is ready immediately at the end of the process. The

  11. Volume measurement study for large scale input accountancy tank

    International Nuclear Information System (INIS)

    Uchikoshi, Seiji; Watanabe, Yuichi; Tsujino, Takeshi

    1999-01-01

    Large Scale Tank Calibration (LASTAC) facility, including an experimental tank which has the same volume and structure as the input accountancy tank of Rokkasho Reprocessing Plant (RRP) was constructed in Nuclear Material Control Center of Japan. Demonstration experiments have been carried out to evaluate a precision of solution volume measurement and to establish the procedure of highly accurate pressure measurement for a large scale tank with dip-tube bubbler probe system to be applied to the input accountancy tank of RRP. Solution volume in a tank is determined from substitution the solution level for the calibration function obtained in advance, which express a relation between the solution level and its volume in the tank. Therefore, precise solution volume measurement needs a precise calibration function that is determined carefully. The LASTAC calibration experiments using pure water showed good result in reproducibility. (J.P.N.)

  12. Ocular volume measured by CT scans

    International Nuclear Information System (INIS)

    Hahn, F.J.; Wei-Kom Chu

    1984-01-01

    Newer CT scans have greatly enhanced oculometric research and made it possible to measure ocular dimensions. With these measurements, ocular volume can be more accurately estimated to understand its relationship with age and sex. One hundred CT orbit scans with presumed normal eyes were used for the data base. The mean values and normal variations of ocular volumes at various ages in both sexes are presented. Rapid growth of the eyeball was noted during the first 24 months of age. It reached its peak between the ages of 18 and 30 years of age, after which there was a reduction. Results may be of help in recognizing eye abnormalities such as microophthalmus and macrophthalmia. (orig.)

  13. Measuring industrial energy efficiency: Physical volume versus economic value

    Energy Technology Data Exchange (ETDEWEB)

    Freeman, S.L.; Niefer, M.J.; Roop, J.M.

    1996-12-01

    This report examines several different measures of industrial output for use in constructing estimates of industrial energy efficiency and discusses some reasons for differences between the measures. Estimates of volume-based measures of output, as well as 3 value-based measures of output (value of production, value of shipments, and value added), are evaluated for 15 separate 4-digit industries. Volatility, simple growth rate, and trend growth rate estimates are made for each industry and each measure of output. Correlations are made between the volume- and value-based measures of output. Historical energy use data are collected for 5 of the industries for making energy- intensity estimates. Growth rates in energy use, energy intensity, and correlations between volume- and value-based measures of energy intensity are computed. There is large variability in growth trend estimates both long term and from year to year. While there is a high correlation between volume- and value-based measures of output for a few industries, typically the correlation is low, and this is exacerbated for estimates of energy intensity. Analysis revealed reasons for these low correlations. It appears that substantial work must be done before reliable measures of trends in the energy efficiency of industry can be accurately characterized.

  14. Independent verification of tank volume measurements by pressure-volume authentication

    International Nuclear Information System (INIS)

    Suda, S.C.; Keisch, B.

    1992-01-01

    Brookhaven National Laboratory has developed a portable pressure-volume authenticator** as a standard and means of checking the functionality and quality of bubbler-probe volumetric devices. The pressure-volume authenticator (PVA) consists of an automated electromanometer system that is controlled by a laptop computer, and a transportable volumetric artifact. A portable pressure gage is connected, via a scanivalve, to the operator's bubbler-probe system and independently measures all bubbler probes. The transportable volumetric artifact is a one-meter high vessel equipped with bubble-probes, computer controlled air-purge rotameters, and platinum resistance (RTD) thermometer. High quality measurements are obtained by use of a fast sampling technique and sophisticated software developed under this program. The computer software performs the following functions: (a) instrument control, (b) data acquisition, (c) on-line graphical and numerical display of measurement data, and (d) detailed data analysis. The device also may provide hands-on training for inspectors and plant operators in high quality volumetric data collection and analysis. A field demonstration of the automated electromanometer system was conducted on the PETRA input accountancy tank, JRC-Ispra in November 1991

  15. Prostate volume measurement by TRUS using heights obtained by transaxial and midsagittal scaning: comparison with specimen volume following radical prostatectomy

    International Nuclear Information System (INIS)

    Park, Bung Bin; Kim, Jae Kyun; Choi, Sung Hoon; Noh, Han Na; Ji, Eun Kyung; Cho, Kyoung Sik

    2000-01-01

    The purpose of this study was to determine, when measuring prostate volume by TRUS, whether height is more accurately determined by transaxial or midsagittal scanning. Sixteen patients who between March 1995 and March 1998 underwent both preoperative TRUS and radical prostatectomy for prostate cancer were included in this study. Using prolate ellipse volume calculation (height x length x width x π/6), TRUS prostate volume was determined, and was compared with the measured volume of the specimen. Prostate volume measured by TRUS, regardless of whether height was determined transaxially or midsagittally, correlated closely with real specimen volume. When height was measured in one of these planes, a paired t test revealed no significant difference between TRUS prostate volume and real specimen volume (p = .411 and p = .740, respectively), nor were there significant differences between the findings of transaxial and midsagittal scanning (p = .570). A paired sample test, however, indicated that TRUS prostate volumes determined transaxially showed a higher correlation coefficient (0.833) and a lower standard deviation (9.04) than those determined midsagittally (0.714 and 11.48, respectively). Prostate volume measured by TRUS closely correlates with real prostate volume. Furthermore, we suggest that when measuring prostate volume in this way, height is more accurately determined by transaxial than by midsagittal scanning

  16. ESB application for effective synchronization of large volume measurements data

    CERN Document Server

    Wyszkowski, Przemysław Michał

    2011-01-01

    The TOTEM experiment at CERN aims at measurement of total cross section, elastic scattering and diffractive processes of colliding protons in the Large Hadron Collider. In order for the research to be possible, it is necessary to process huge amounts of data coming from variety of sources: TOTEM detectors, CMS detectors, measurement devices around the Large Hadron Collider tunnel and many other external systems. Preparing final results involves also calculating plenty of intermediate figures, which also need to be stored. In order for the work of the scientist to be effective and convenient it is crucial to provide central point for the data storage, where all raw and intermediate figures will be stored. This thesis aims at presenting the usage of Enterprise Service Bus concept in building software infrastructure for transferring large volume of measurements data. Topics discussed here include technologies and mechanisms realizing the concept of integration bus, model of data transferring system based on ...

  17. Measurements of volumic activity of radon in indoor air in dwellings and enclosed work areas in Morocco

    International Nuclear Information System (INIS)

    Hakam, O. K.; Lferde, M.

    1994-01-01

    The principal source of exposure to radiation for public in built-up areas is known to be the inhalation of radon and its short-lived daughters. Most of this exposure occurs inside homes, where many hours are spent each day and where the volumic activity of radon are usually higher than outdoors. For measure these volumic activity, cellulose nitrate films LR-115 type II already calibrated of volumic activity of radon are used. The measurements were performed in 30 dwellings and enclosed work areas in different regions of Morocco. The volumic mean activity obtained in dwellings is 64 +- 5 Bq/m sup 3 in Rabat, 59 +- 6 Bq/ m sup 3 in Kenitra, 124 +- 8 Bq/ m sup 3 in youssoufia and 136 +- 9 Bq/ m sup 3 in Khouribga. It was showed that the volumic activity of radon are more higher in two factory locals of moroccan ores treatment than in dwellings. The average volumic activity of radon in geophysical observatory cellar in Berchid was 1541 +- 64 Bq/ m sup 3. We also observed that the volumic activity of radon in indoor air is more higher in winter than in summer and it decrease with altitude and increase with depth. 4 tabs. 2 refs. (author)

  18. Measurement of lung volumes : usefulness of spiral CT

    International Nuclear Information System (INIS)

    Kang, Ho Yeong; Kwak, Byung Kook; Lee, Sang Yoon; Kim, Soo Ran; Lee, Shin Hyung; Lee, Chang Joon; Park, In Won

    1996-01-01

    To evaluate the usefulness of spiral CT in the measurement of lung volumes. Fifteen healthy volunteers were studied by both spirometer and spiral CT at full inspiration and expiration in order to correlated their results, including total lung capacity (TLC), vital capacity (VC) and residual volume (RV). 3-D images were reconstructed from spiral CT, and we measured lung volumes at a corresponding CT window range ; their volumes were compared with the pulmonary function test (paired t-test). The window range corresponding to TLC was from -1000HU to -150HU (p=0.279, r=0.986), and for VC from -910HU to -800HU (p=0.366, r=0.954) in full-inspiratory CT. The optimal window range for RV in full-expiratory CT was from -1000HU to -450HU (p=0.757, r=0.777), and TLC-VC in full-inspiratory CT was also calculated (p=0.843, r=0.847). Spiral CT at full inspiration can used to lung volumes such as TLC, VC and RV

  19. Acoustic beam steering by light refraction: illustration with directivity patterns of a tilted volume photoacoustic source.

    Science.gov (United States)

    Raetz, Samuel; Dehoux, Thomas; Perton, Mathieu; Audoin, Bertrand

    2013-12-01

    The symmetry of a thermoelastic source resulting from laser absorption can be broken when the direction of light propagation in an elastic half-space is inclined relatively to the surface. This leads to an asymmetry of the directivity patterns of both compressional and shear acoustic waves. In contrast to classical surface acoustic sources, the tunable volume source allows one to take advantage of the mode conversion at the surface to control the directivity of specific modes. Physical interpretations of the evolution of the directivity patterns with the increasing light angle of incidence and of the relations between the preferential directions of compressional- and shear-wave emission are proposed. In order to compare calculated directivity patterns with measurements of normal displacement amplitudes performed on plates, a procedure is proposed to transform the directivity patterns into pseudo-directivity patterns representative of the experimental conditions. The comparison of the theoretical with measured pseudo-directivity patterns demonstrates the ability to enhance bulk-wave amplitudes and to steer specific bulk acoustic modes by adequately tuning light refraction.

  20. Measurement properties and usability of non-contact scanners for measuring transtibial residual limb volume.

    Science.gov (United States)

    Kofman, Rianne; Beekman, Anna M; Emmelot, Cornelis H; Geertzen, Jan H B; Dijkstra, Pieter U

    2018-06-01

    Non-contact scanners may have potential for measurement of residual limb volume. Different non-contact scanners have been introduced during the last decades. Reliability and usability (practicality and user friendliness) should be assessed before introducing these systems in clinical practice. The aim of this study was to analyze the measurement properties and usability of four non-contact scanners (TT Design, Omega Scanner, BioSculptor Bioscanner, and Rodin4D Scanner). Quasi experimental. Nine (geometric and residual limb) models were measured on two occasions, each consisting of two sessions, thus in total 4 sessions. In each session, four observers used the four systems for volume measurement. Mean for each model, repeatability coefficients for each system, variance components, and their two-way interactions of measurement conditions were calculated. User satisfaction was evaluated with the Post-Study System Usability Questionnaire. Systematic differences between the systems were found in volume measurements. Most of the variances were explained by the model (97%), while error variance was 3%. Measurement system and the interaction between system and model explained 44% of the error variance. Repeatability coefficient of the systems ranged from 0.101 (Omega Scanner) to 0.131 L (Rodin4D). Differences in Post-Study System Usability Questionnaire scores between the systems were small and not significant. The systems were reliable in determining residual limb volume. Measurement systems and the interaction between system and residual limb model explained most of the error variances. The differences in repeatability coefficient and usability between the four CAD/CAM systems were small. Clinical relevance If accurate measurements of residual limb volume are required (in case of research), modern non-contact scanners should be taken in consideration nowadays.

  1. Measurable inhomogeneities in stock trading volume flow

    Science.gov (United States)

    Cortines, A. A. G.; Riera, R.; Anteneodo, C.

    2008-08-01

    We investigate the statistics of volumes of shares traded in stock markets. We show that the stochastic process of trading volumes can be understood on the basis of a mixed Poisson process at the microscopic time level. The beta distribution of the second kind (also known as q-gamma distribution), that has been proposed to describe empirical volume histograms, naturally results from our analysis. In particular, the shape of the distribution at small volumes is governed by the degree of granularity in the trading process, while the exponent controlling the tail is a measure of the inhomogeneities in market activity. Furthermore, the present case furnishes empirical evidence of how power law probability distributions can arise as a consequence of a fluctuating intrinsic parameter.

  2. Quantitation of mandibular ramus volume as a source of bone grafting.

    Science.gov (United States)

    Verdugo, Fernando; Simonian, Krikor; Smith McDonald, Roberto; Nowzari, Hessam

    2009-10-01

    When alveolar atrophy impairs dental implant placement, ridge augmentation using mandibular ramus graft may be considered. In live patients, however, an accurate calculation of the amount of bone that can be safely harvested from the ramus has not been reported. The use of a software program to perform these calculations can aid in preventing surgical complications. The aim of the present study was to intra-surgically quantify the volume of the ramus bone graft that can be safely harvested in live patients, and compare it to presurgical computerized tomographic calculations. The AutoCAD software program quantified ramus bone graft in 40 consecutive patients from computerized tomographies. Direct intra-surgical measurements were recorded thereafter and compared to software data (n = 10). In these 10 patients, the bone volume was also measured at the recipient sites 6 months post-sinus augmentation. The mandibular second and third molar areas provided the thickest cortical graft averaging 2.8 +/- 0.6 mm. The thinnest bone was immediately posterior to the third molar (1.9 +/- 0.3 mm). The volume of ramus bone graft measured by AutoCAD averaged 0.8 mL (standard deviation [SD] 0.2 mL, range: 0.4-1.2 mL). The volume of bone graft measured intra-surgically averaged 2.5 mL (SD 0.4 mL, range: 1.8-3.0 mL). The difference between the two measurement methods was significant (p AutoCAD software program did not overestimate the volume of bone that can be safely harvested from the mandibular ramus.

  3. Bulk-volume behavior of pressure-densified amorphous polymers and free-volume behavior by positron annihilation lifetime measurement

    International Nuclear Information System (INIS)

    Hagiwara, K.; Ougizawa, T.; Inoue, T.; Hirata, K.; Kobayashi, Y.

    2001-01-01

    In order to study the nature of amorphous polymers, the free volume contribution on the bulk volume change was investigated on the basis of the relationship between the bulk volume behavior by PVT (pressure-volume-temperature) measurement and the free volume behavior by PALS (positron annihilation lifetime spectroscopy) measurement. A densified glass, prepared by cooling at constant rate from the melt state temperature to room temperature under 200 MPa, showed smaller bulk volume and free volume than non-densified glass. And the densified glass showed not only the same glass transition temperature (Tg) as non-densified glass but also another transition at lower temperature around (Tg-30 C). In this glass-glass transition, both the bulk volume and free volume of densified glass recovered to those of non-densified glass. Moreover the densified glass showed different thermal behavior from the glass which was enthalpy-relaxed under atmospheric pressure. From those results, it was considered that the free volume behavior largely related to the behavior of amorphous polymers. (orig.)

  4. Cosmological measure with volume averaging and the vacuum energy problem

    Science.gov (United States)

    Astashenok, Artyom V.; del Popolo, Antonino

    2012-04-01

    In this paper, we give a possible solution to the cosmological constant problem. It is shown that the traditional approach, based on volume weighting of probabilities, leads to an incoherent conclusion: the probability that a randomly chosen observer measures Λ = 0 is exactly equal to 1. Using an alternative, volume averaging measure, instead of volume weighting can explain why the cosmological constant is non-zero.

  5. Cosmological measure with volume averaging and the vacuum energy problem

    International Nuclear Information System (INIS)

    Astashenok, Artyom V; Del Popolo, Antonino

    2012-01-01

    In this paper, we give a possible solution to the cosmological constant problem. It is shown that the traditional approach, based on volume weighting of probabilities, leads to an incoherent conclusion: the probability that a randomly chosen observer measures Λ = 0 is exactly equal to 1. Using an alternative, volume averaging measure, instead of volume weighting can explain why the cosmological constant is non-zero. (paper)

  6. [Failure of static pulmonary volume measurements in mucoviscidosis].

    Science.gov (United States)

    Haluszka, J; Zebrak, J

    1984-01-01

    With worsening of bronchial obstruction during the course of cystic fibrosis the functional residual capacity (CRF) measured by plethysmography increases progressively. The difference between values of CRF obtained by plethysmography or by Helium dilution increases even more. The difference between the two methods (for CRF) is supposed to show the volume of "trapped"' gas. A similar outcome, although less marked, is observed after physiotherapy. The extent of pulmonary distention and gas trapping is markedly overestimated by plethysmographic measurements, when one considers the anatomical and radiological anomalies. It was recently suggested that the rise in compliance of the walls of the extra-thoracic airways in the presence of bronchial obstruction may lead to an over-estimation of the pulmonary volumes measured by plethysmography. This may be the case during the course of mucoviscidosis, when repeated infections lead to a destruction of the bronchial walls. However, this anomaly does not explain this rise in CRF after mucolytic treatment and postural drainage. The CRF seems to reflect not only the volume of trapper gas in the lung, but equally the failure to equalize the interior pressures of the obstructed airways. In order to appreciate the effects of respiratory physiotherapy, different methods of measuring pulmonary volumes are necessary but the interpretation of the results take account of the complex meterology.

  7. Measurement of maxillary sinus volume using Computed Tomography

    International Nuclear Information System (INIS)

    Park, Chang Hee; Kim, Kee Deog; Park, Chang Seo

    2000-01-01

    To propose a standard value for the maxillary sinus volume of a normal Korean adult by measuring the width and height of the sinus and analyzing their correlation and the difference of the sinus size respectively between sexes, and on the right and left sides. Fifty-two (95 maxillary sinuses) out of 20 years or over aged patients who had taken CT in the Department of Dental Radiology, Yonsei University, Dental Hospital, between February 1997 and July 1999 who were no specific symptom, prominent bony septa, pathosis, clinical asymmetry and history of surgery in the maxillary sinus were retrospectively analyzed. The mean transverse width, antero-posterior width, height and volume of the normal Korean adult's maxillary sinuses were 28.33 mm, 39.69 mm, 46.60 mm and 21.90 cm 3 , respectively. There was a significant sex difference in the sinus volume (p<0.05). In the mean antero-posterior width, height and volume of the sinus, no significant difference was observed between both sides. All four measurements showed a significant correlation between both sides (p<0.0001). The widths and height of the sinus all showed a significant correlation with the sinus volume (p<0.0001). In the Korean normal adult's maxillary sinus, males tended to be larger than females. Except for the transverse width, all of the measurements showed no significant difference between the right and left side, but significant correlations in the four measurements between both sides were observed. Thus, the overgrowth or undergrowth in the unilateral maxillary sinus may suggest a certain pathosis or developmental abnormalities in the maxillary sinus.

  8. Automated measurement of local white matter lesion volume

    DEFF Research Database (Denmark)

    van der Lijn, Fedde; Verhaaren, Benjamin F. J.; Ikram, M. Arfan

    2012-01-01

    in a periventricular region close to the ventricles and a subcortical zone further away. In this work we present a novel automated method for local white matter lesion volume quantification in magnetic resonance images. The method segments and measures the white matter lesion volume in 43 regions defined...

  9. Measurement of CSF volume with 3D-FASE MRI

    International Nuclear Information System (INIS)

    Kanayama, Shoichi; Calderon, A.; Makita, Jun-ichi; Ohara, Yukou; Tsunoda, Akira; Sato, Kiyoshi.

    1997-01-01

    A noninvasive and fast cerebrospinal fluid (CSF) volume measurement method has been developed using 3D-FASE MRI and a semi-automatic segmentation process. Images with a high CSF/(gray and white matter) ratio (about 10-20) were obtained with a heavily T 2 weighted 3D-FASE sequence. The CSF region was segmented with a region growing method and the volume was calculated from the number of segmented voxels with a signal intensity weighted summation. Total measurement time was about 30 minutes for each study. The errors of the measured volumes were within 10% for the phantom experiments. Intracranial CSF volumes of normal volunteers ranged between about 100 and 200 cc and the ventricle/intracranial CSF ratio was about 10%. 3D display of the segmented intracranial and ventricle CSF regions was also carried out and proved to be useful to understand the anatomy. Increased intracranial and/or ventricle CSF volumes were obtained for a hydrocephalic patient and one patient with probable cerebral atrophy. The results suggest that the developed method could be used for the diagnosis of patients with neurological diseases. (author)

  10. A pilot study to assess the feasibility of measurement of adrenal gland volume by magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Grant, Lee A.; Dixon, Adrian K. (Dept. of Radiology, Cambridge Univ. Teaching Hospitals NHS Foundation Trust, Cambridge (United Kingdom)), e-mail: leegrant100@gmail.com; Napolitano, Antonella; McHugh, Simon M. (GlaxoSmithKline RandD, Clinical Unit Cambridge, Addenbrooke' s Centre for Clinical Investigation, Addenbrooke' s Hospital, Cambridge (United Kingdom)); Miller, Sam (Analysis Applications Research Group, GSK RandD, Harlow, Essex (United Kingdom)); Stephens, Kimberley (Discovery Statistics, GSK RandD, Harlow, Essex (United Kingdom))

    2010-01-15

    Background: Repeated computed tomography (CT) assessment of the adrenal glands is associated with a significant radiation burden. The increasing capabilities of magnetic resonance (MR) volumetric analysis of the adrenals make this a potentially alternative technique in man. Purpose: To determine whether MR imaging could be used to measure adrenal volume, and to determine the intra- and interobserver variation and repeatability of MR volume imaging of adrenals in healthy human subjects. Material and Methods: This was a single-cohort, sequential design, three-part study involving four MRI examinations per subject following ethical approval and informed consent. Information was collected on four healthy subjects (three male and one female). Two different investigators estimated the area of the adrenal gland for each of the 3-mm contiguous slices (and consequently adrenal volume). In order to estimate inter- and intrareader variability, a repeated-measures mixed model was fitted with adrenal volume as the dependent variable. In order to estimate any bias between readers, Bland-Altman methodology was applied. Results: Intraobserver variation for adrenal gland volume is approximately 5% of a 3-cm3 adrenal gland. Interobserver variation is approximately 9% of a 3-cm3 adrenal gland. Potential variation in measurement for adrenal volume from all sources equates to approximately 14% of a 3-cm3 adrenal gland. Verification of image reading by a second investigator (consensus reading) reduces variability. Conclusion: Analysis of adrenal gland volume using MRI is a potentially reliable technique that could be used to assess a pathological change in adrenal size

  11. High-pitch dual-source CT coronary angiography with low volumes of contrast medium

    International Nuclear Information System (INIS)

    Lembcke, Alexander; Hein, Patrick A.; Knobloch, Gesine; Durmus, Tahir; Hamm, Bernd; Schwenke, Carsten; Huppertz, Alexander

    2014-01-01

    To assess the effect of lower volumes of contrast medium (CM) on image quality in high-pitch dual-source computed tomography coronary angiography (CTCA). One-hundred consecutive patients (body weight 65-85 kg, stable heart rate ≤65 bpm, cardiac index ≥2.5 L/min/m 2 ) referred for CTCA were prospectively enrolled. Patients were randomly assigned to one of five groups of different CM volumes (G 30 , 30 mL; G 40 , 40 mL; G 50 , 50 mL; G 60 , 60 mL; G 70 , 70 mL; flow rate 5 mL/s each, iodine content 370 mg/mL). Attenuation within the proximal and distal coronary artery segments was analysed. Mean attenuation for men and women ranged from 345.0 and 399.1 HU in G 30 to 478.2 and 571.8 HU in G 70 . Mean attenuation values were higher in groups with higher CM volumes (P 30 , G 40 , G 50 , G 60 and G 70 were 89 %, 95 %, 98 %, 98 % and 99 %. CM volume of 30 mL in women and 40 mL in men proved to be sufficient to guarantee attenuation of at least 300 HU. In selected patients high-pitch dual-source CTCA can be performed with CM volumes of 40 mL in men or 30 mL in women. (orig.)

  12. Effects of the volume and shape of voxels on the measurement of phantom volume using three-dimensional magnetic resonance imaging

    International Nuclear Information System (INIS)

    Mori, Koichi; Tonami, Syuichi; Nakamura, Mamoru; Kuranishi, Makoto; Hagino, Hirofumi; Saitou, Osamu; Yotsutsuji, Takashi

    2002-01-01

    Recently, an increasing number of volumetric studies of the human brain have been reported, using three-dimensional magnetic resonance imaging (3D-MRI). To our knowledge, however, there are few investigations on the relation of the volume and shape of voxels which constitute and MR image to the accuracy in volume measurement of an imaged object. The purpose of this study was to evaluate the effect of a different shape of voxel, that is, isotropic or anisotropic, as well as the volume of a voxel on the volume measurement based on the original image data and multiplanar reconstruction (MPR) data, respectively. In the experiment, we repeatedly acquired contiguous sagittal images of a single globe phantom with a known volume under the condition in which the volume and shape of voxels varied, on a 1.5 T MR scanner. We used a gradient echo sequence (3D FLASH). The volume of the globe phantom from both original images and MPR ones was measured on workstations employing a semi-automated local thresholding technique. As a result, the smaller volume of voxels tended to give us the more correct measurement, and an isotropic voxel reduced measurement errors as compared to an anisotropic one. Therefore, it is concluded that the setting of voxel with both an isotropic shape and small volume, e.g., a voxel of 1 mm x 1 mm x 1 mm at present, is recommended in order to get a precise volume measurement using 3D-MRI. (author)

  13. [Effects of the volume and shape of voxels on the measurement of phantom volume using three-dimensional magnetic resonance imaging].

    Science.gov (United States)

    Mori, Koichi; Hagino, Hirofumi; Saitou, Osamu; Yotsutsuji, Takashi; Tonami, Syuichi; Nakamura, Mamoru; Kuranishi, Makoto

    2002-01-01

    Recently, an increasing number of volumetric studies of the human brain have been reported, using three-dimensional magnetic resonance imaging (3D-MRI). To our knowledge, however, there are few investigations on the relation of the volume and shape of voxels which constitute an MR image to the accuracy in volume measurement of an imaged object. The purpose of this study was to evaluate the effect of a different shape of voxel, that is, isotropic or anisotropic, as well as the volume of a voxel on the volume measurement based on the original image data and multiplanar reconstruction (MPR) data, respectively. In the experiment, we repeatedly acquired contiguous sagittal images of a single globe phantom with a known volume under the condition in which the volume and shape of voxels varied, on a 1.5T MR scanner. We used a gradient echo sequence (3D FLASH). The volume of the globe phantom from both original images and MPR ones was measured on workstations employing a semi-automated local thresholding technique. As a result, the smaller volume of voxels tended to give us the more correct measurement, and an isotropic voxel reduced measurement errors as compared to an anisotropic one. Therefore, it is concluded that the setting of voxel with both an isotropic shape and small volume, e.g., a voxel of 1 mm x 1 mm x 1 mm at present, is recommended in order to get a precise volume measurement using 3D-MRI.

  14. Vibrational excitation in a hydrogen volume source

    International Nuclear Information System (INIS)

    Eenshuistra, P.J.

    1989-01-01

    In this thesis the complex of processes which determines the D - or H - density in a volume source, a hydrogen discharge, is studied. D - beams are of interest for driving the current of a fusion plasma in a TOKAMAK. Densities of vibrationally excited molecules, of H atoms, and of metastable hydrogen molecules were determined using Resonance-Enhanced MultiPhoton Ionization (REMPI). An experiment in which vibrationally highly excited molecules are formed by recombination of atoms in a cold metal surface, is described. The production and destruction of vibrationally excited molecules and atoms in the discharge is discussed. The vibrational distribution for 3≤ν≤5 (ν = vibrational quantumnumber) is strongly super-thermal. This effect is more apparent at higher discharge current and lower gas pressure. The analysis with a model based on rate equations, which molecules are predominantly produced by primary electron excitation of hydrogen molecules and deexcited upon one wall collision. The atom production is compatible with dissociation of molecules by primary electrons, dissociation of molecules on the filaments, and collisions between positive ions and electrons. The electrons are predominantly destroyed by recombination on the walls. Finally the production and destruction of H - in the discharge are discussed. The density of H - in the plasma, the electron density and temperature were determined. H - extraction was measured. The ratio of the extracted H - current and the H - density in the plasma gives an indication of the drift velocity of H - in the plasma. This velocity determines the emittance of the extracted beam. It was found that the H - velocity scales with the square root of the electron temperature. The measured H - densities are compatible with a qualitative model in which dissociative attachment of plasma electrons to vibrationally excited molecules is the most important process. (author). 136 refs.; 39 figs.; 10 tabs

  15. Micro analysis of fringe field formed inside LDA measuring volume

    International Nuclear Information System (INIS)

    Ghosh, Abhijit; Nirala, A K

    2016-01-01

    In the present study we propose a technique for micro analysis of fringe field formed inside laser Doppler anemometry (LDA) measuring volume. Detailed knowledge of the fringe field obtained by this technique allows beam quality, alignment and fringe uniformity to be evaluated with greater precision and may be helpful for selection of an appropriate optical element for LDA system operation. A complete characterization of fringes formed at the measurement volume using conventional, as well as holographic optical elements, is presented. Results indicate the qualitative, as well as quantitative, improvement of fringes formed at the measurement volume by holographic optical elements. Hence, use of holographic optical elements in LDA systems may be advantageous for improving accuracy in the measurement. (paper)

  16. Measurement of cell volume changes by fluorescence self-quenching

    DEFF Research Database (Denmark)

    Hamann, Steffen; Kiilgaard, J.F.; Litman, Thomas

    2002-01-01

    At high concentrations, certain fluorophores undergo self-quenching, i.e., fluorescence intensity decreases with increasing fluorophore concentration. Accordingly, the self-quenching properties can be used for measuring water volume changes in lipid vesicles. In cells, quantitative determination...... concentrations of the fluorophore calcein suitable for measurement of changes in cell water volume by self-quenching. The relationship between calcein fluorescence intensity, when excited at 490 nm (its excitation maximum), and calcein concentration was investigated in vitro and in various cultured cell types...... to a decrease in calcein fluorescence with high signal-to-noise ratio (>15). Similar results were obtained with the fluorophore BCECF when excited at its isosbestic wavelength (436 nm). The present results demonstrate the usefulness of fluorescence self-quenching to measure rapid changes in cell water volume....

  17. Tank waste source term inventory validation. Volume II. Letter report

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-04-01

    This document comprises Volume II of the Letter Report entitled Tank Waste Source Term Inventory Validation. This volume contains Appendix C, Radionuclide Tables, and Appendix D, Chemical Analyte Tables. The sample data for selection of 11 radionuclides and 24 chemical analytes were extracted from six separate sample data sets, were arranged in a tabular format and were plotted on scatter plots for all of the 149 single-shell tanks, the 24 double-shell tanks and the four aging waste tanks. The solid and liquid sample data was placed in separate tables and plots. The sample data and plots were compiled from the following data sets: characterization raw sample data, recent core samples, D. Braun data base, Wastren (Van Vleet) data base, TRAC and HTCE inventories.

  18. Tank waste source term inventory validation. Volume II. Letter report

    International Nuclear Information System (INIS)

    1995-04-01

    This document comprises Volume II of the Letter Report entitled Tank Waste Source Term Inventory Validation. This volume contains Appendix C, Radionuclide Tables, and Appendix D, Chemical Analyte Tables. The sample data for selection of 11 radionuclides and 24 chemical analytes were extracted from six separate sample data sets, were arranged in a tabular format and were plotted on scatter plots for all of the 149 single-shell tanks, the 24 double-shell tanks and the four aging waste tanks. The solid and liquid sample data was placed in separate tables and plots. The sample data and plots were compiled from the following data sets: characterization raw sample data, recent core samples, D. Braun data base, Wastren (Van Vleet) data base, TRAC and HTCE inventories

  19. Simulation study of a magnetocardiogram based on a virtual heart model: effect of a cardiac equivalent source and a volume conductor

    International Nuclear Information System (INIS)

    Shou Guo-Fa; Xia Ling; Dai Ling; Ma Ping; Tang Fa-Kuan

    2011-01-01

    In this paper, we present a magnetocardiogram (MCG) simulation study using the boundary element method (BEM) and based on the virtual heart model and the realistic human volume conductor model. The different contributions of cardiac equivalent source models and volume conductor models to the MCG are deeply and comprehensively investigated. The single dipole source model, the multiple dipoles source model and the equivalent double layer (EDL) source model are analysed and compared with the cardiac equivalent source models. Meanwhile, the effect of the volume conductor model on the MCG combined with these cardiac equivalent sources is investigated. The simulation results demonstrate that the cardiac electrophysiological information will be partly missed when only the single dipole source is taken, while the EDL source is a good option for MCG simulation and the effect of the volume conductor is smallest for the EDL source. Therefore, the EDL source is suitable for the study of MCG forward and inverse problems, and more attention should be paid to it in future MCG studies. (general)

  20. Photon sources for absorptiometric measurements

    International Nuclear Information System (INIS)

    Witt, R.M.; Sandrik, J.M.; Cameron, J.R.

    1976-01-01

    Photon absorptiometry is defined and the requirements of photon sources for these measurements are described. Both x-ray tubes and radionuclide sources are discussed, including the advantages of each in absorptiometric systems

  1. Calibration of a solid state nuclear track detector for the measurements of volumic activity of Radon

    International Nuclear Information System (INIS)

    HAKAM, O.K.; LFERDE, M.; BERRADA, M.

    1994-01-01

    Time - integrated measurements of environmental radiation activity are commonly carried out using solid state nuclear track detectors ( SSNTD ). These detectors should be calibrated of volumic activity of radon. This paper reports the results of experiments conducted to calibrate cellulose nitrate films LR - 115 type II used for measurements of volumic activity of radon in indoor air in dwellings and enclosed work areas in Morocco. Calibration measurements were made in laboratory using a calibration chamber and a radon source. The calibration chamber is a cylindric box ( 2613,6 cm sup 3)which we have manufactured of aluminium. The radon source is a natural sample rich of aluminium (17,29 + 0 ,12) Bq/g. The films are placed in detector holder with membrane and exposed inside the calibration chamber to varying concentrations of radon. Following the exposure, the films were chemically etched in sodium hydroxide (2,5 N) at 60 C for 120 minutes. The number of registered alpha particle tracks were counted with an optical microscope. In the used etching conditions, the removed mean thickness is in the order of 6 micro m. Therefore, we have normalized the track density to this value . We obtained a calibration factor of 0, 58 tracks . cm sup -2/ K Bq . h . m sup -3 . 1 tab.; 1 fig.; 2 refs. (author)

  2. Measuring Conflict in a Multi-Source Environment as a Normal Measure

    OpenAIRE

    Wei, Pan; Ball, John E.; Anderson, Derek T.; Harsh, Archit; Archibald, Christopher

    2018-01-01

    In a multi-source environment, each source has its own credibility. If there is no external knowledge about credibility then we can use the information provided by the sources to assess their credibility. In this paper, we propose a way to measure conflict in a multi-source environment as a normal measure. We examine our algorithm using three simulated examples of increasing conflict and one experimental example. The results demonstrate that the proposed measure can represent conflict in a me...

  3. Method of measuring a liquid pool volume

    Science.gov (United States)

    Garcia, G.V.; Carlson, N.M.; Donaldson, A.D.

    1991-03-19

    A method of measuring a molten metal liquid pool volume and in particular molten titanium liquid pools is disclosed, including the steps of (a) generating an ultrasonic wave at the surface of the molten metal liquid pool, (b) shining a light on the surface of a molten metal liquid pool, (c) detecting a change in the frequency of light, (d) detecting an ultrasonic wave echo at the surface of the molten metal liquid pool, and (e) computing the volume of the molten metal liquid. 3 figures.

  4. Excess free volume in metallic glasses measured by X-ray diffraction

    International Nuclear Information System (INIS)

    Yavari, Alain Reza; Moulec, Alain Le; Inoue, Akihisa; Nishiyama, Nobuyuki; Lupu, Nicoleta; Matsubara, Eiichiro; Botta, Walter Jose; Vaughan, Gavin; Di Michiel, Marco; Kvick, Ake

    2005-01-01

    In crystalline materials, lattice expansion as measured by diffraction methods differs from the expansion of the sample dimensions as measured by dilatometry, due to the contribution of thermal vacancies to the latter. We have found that in glassy materials and metallic glasses in particular, this is not the case for the contribution of free volume. These findings are the first direct experimental confirmation of simulation results indicating that atomic size holes are unstable in glasses such that free volume is dispersed randomly. This allows direct measurement of excess free volume in glasses using diffraction methods in place of dilatometry, which is difficult to use once the sample softens at the glass transition temperature T g and above. Quenched-in and deformation-induced free-volume ΔV f were measured by X-ray diffraction in transmission during heating using synchrotron light. The measured thermal expansion coefficients α th were the same as in dilatometry. The glass transition T g appeared as a break in the value of α th at T g . The 'change-of-slope method' was applied to the kinetics of relaxation to derive the activation energy for the free-volume annihilation process

  5. Bioimpedance measurement of body water correlates with measured volume balance in injured patients.

    Science.gov (United States)

    Rosemurgy, A S; Rodriguez, E; Hart, M B; Kurto, H Z; Albrink, M H

    1993-06-01

    Bioimpedance technology is being used increasingly to determine drug volume of distribution, body water status, and nutrition repletion. Its accuracy in patients experiencing large volume flux is not established. To address this, we undertook this prospective study in 54 consecutive seriously injured adults who had emergency celiotomy soon after arrival in the emergency department. Bioimpedance measurements were obtained in the emergency department before the patient was transported to the operating room, on completion of celiotomy, and 24 hours and 48 hours after celiotomy. Bioimpedance measurements of body water were compared with measured fluid balance. If insensible losses are subtracted from measured fluid balance, the percentage of body weight, which is body water determined by bioimpedance, closely follows fluid flux. This study supports the use of bioimpedance measurements in determining total body water even during periods of surgery, blood loss, and vigorous resuscitation.

  6. Multi-slice CT three dimensional volume measurement of tumors and livers in hepatocellular carcinoma

    International Nuclear Information System (INIS)

    Yu Yuanlong; Li Liangcai; Tang Binghang; Hu Zemin

    2004-01-01

    Objective: To examine the accuracy of multi-slice CT (MSCT) three dimensional (3D) volume measurement of tumors and livers in hepatocellular carcinoma cases by using immersion method as the standard. Methods: (1) The volume of 25 porkling livers was measured using immersion method in experiment group in vitro. Then the models were built according to Matsumoto's method and CT scanning and special software were used to measure the volume of the livers. (2) The volume of the tumors in 25 cases of hepatocellular carcinoma was measured using diameter measurement method and special volume measurement software (tissue measurements). Two tumors of them were measured respectively using MSCT 3D measurement, diameter measurement before the operation and immersion method after the operation. The data of the two groups were examined using pairing t test. Results: (1) The volume range of 25 porkling livers was 68.50-1150.10 ml using immersion method and 69.78-1069.97 ml using MSCT 3D measurement. There was no significant difference of the data in these two groups using t-test (t=1.427, P>0.05). (2) The volume range of 25 hepatocellular tumors was 395.16-2747.7 ml using diameter measurement and 203.10-1463.19 ml using MSCT 3D measurement before the operation. There was significant difference of the data in these two groups using t-test (t=7.689, P<0.001). In 2 ablated tumors, 1 case's volume was (21.75±0.60) ml using MSCT 3D measurement and 33.73 ml using diameter measurement before the operation and 21.50 ml using immersion measurement after the operation. The other case's volume was (696.13±5.30) ml using MSCT 3D measurement and 1323.51 ml using diameter measurement before the operation and 685.50 ml using immersion measurement after the operation. Conclusion: MSCT 3D volume measurement can accurately measure the volume of tumor and liver and has important clinical application value. There is no significant difference between MSCT 3D volume measurement and immersion method

  7. Critical Evaluation of Blood Volume Measurements during Hemodialysis

    NARCIS (Netherlands)

    Dasselaar, Judith J.; van der Sande, Frank M.; Franssen, Casper F. M.

    2012-01-01

    Devices that continuously measure relative blood volume (RBV) changes during hemodialysis (HD) are increasingly used for the prevention of dialysis hypotension and fine-tuning of dry weight. However, RBV measurements are subject to various limitations. First, RBV devices provide information on

  8. Ice thickness measurements and volume estimates for glaciers in Norway

    Science.gov (United States)

    Andreassen, Liss M.; Huss, Matthias; Melvold, Kjetil; Elvehøy, Hallgeir; Winsvold, Solveig H.

    2014-05-01

    Whereas glacier areas in many mountain regions around the world now are well surveyed using optical satellite sensors and available in digital inventories, measurements of ice thickness are sparse in comparison and a global dataset does not exist. Since the 1980s ice thickness measurements have been carried out by ground penetrating radar on many glaciers in Norway, often as part of contract work for hydropower companies with the aim to calculate hydrological divides of ice caps. Measurements have been conducted on numerous glaciers, covering the largest ice caps as well as a few smaller mountain glaciers. However, so far no ice volume estimate for Norway has been derived from these measurements. Here, we give an overview of ice thickness measurements in Norway, and use a distributed model to interpolate and extrapolate the data to provide an ice volume estimate of all glaciers in Norway. We also compare the results to various volume-area/thickness-scaling approaches using values from the literature as well as scaling constants we obtained from ice thickness measurements in Norway. Glacier outlines from a Landsat-derived inventory from 1999-2006 together with a national digital elevation model were used as input data for the ice volume calculations. The inventory covers all glaciers in mainland Norway and consists of 2534 glaciers (3143 glacier units) covering an area of 2692 km2 ± 81 km2. To calculate the ice thickness distribution of glaciers in Norway we used a distributed model which estimates surface mass balance distribution, calculates the volumetric balance flux and converts it into thickness using the flow law for ice. We calibrated this model with ice thickness data for Norway, mainly by adjusting the mass balance gradient. Model results generally agree well with the measured values, however, larger deviations were found for some glaciers. The total ice volume of Norway was estimated to be 275 km3 ± 30 km3. From the ice thickness data set we selected

  9. High-pitch dual-source CT coronary angiography with low volumes of contrast medium

    Energy Technology Data Exchange (ETDEWEB)

    Lembcke, Alexander; Hein, Patrick A.; Knobloch, Gesine; Durmus, Tahir; Hamm, Bernd [Charite - University Medicine Berlin, Department of Radiology, Berlin (Germany); Schwenke, Carsten [SCO:SSiS - Schwenke Consulting, Berlin (Germany); Huppertz, Alexander [Charite - University Medicine Berlin, Department of Radiology, Berlin (Germany); ISI - Imaging Science Institute Charite, Berlin (Germany)

    2014-01-15

    To assess the effect of lower volumes of contrast medium (CM) on image quality in high-pitch dual-source computed tomography coronary angiography (CTCA). One-hundred consecutive patients (body weight 65-85 kg, stable heart rate ≤65 bpm, cardiac index ≥2.5 L/min/m{sup 2}) referred for CTCA were prospectively enrolled. Patients were randomly assigned to one of five groups of different CM volumes (G{sub 30}, 30 mL; G{sub 40}, 40 mL; G{sub 50}, 50 mL; G{sub 60}, 60 mL; G{sub 70}, 70 mL; flow rate 5 mL/s each, iodine content 370 mg/mL). Attenuation within the proximal and distal coronary artery segments was analysed. Mean attenuation for men and women ranged from 345.0 and 399.1 HU in G{sub 30} to 478.2 and 571.8 HU in G{sub 70}. Mean attenuation values were higher in groups with higher CM volumes (P < 0.0001) and higher in women than in men (P < 0.0001). The proportions of segments with attenuation of at least 300 HU in G{sub 30}, G{sub 40}, G{sub 50}, G{sub 60} and G{sub 70} were 89 %, 95 %, 98 %, 98 % and 99 %. CM volume of 30 mL in women and 40 mL in men proved to be sufficient to guarantee attenuation of at least 300 HU. In selected patients high-pitch dual-source CTCA can be performed with CM volumes of 40 mL in men or 30 mL in women. (orig.)

  10. Final report on COOMET.RI(II)-S2.Cs-137 (319/RU/04): Comparison measurements of radionuclide volume sources (Cs-137)

    International Nuclear Information System (INIS)

    Korostin, S.; Hernandez, T.; Oropesa, P.; Arnold, D.; Evseev, V.; Ivanukovich, A.; Milevskiy, V.; Svec, A.; Lapenas, A.; Andonova, V.; Steiner, V.

    2010-01-01

    Measurements of the Cs-137 specific activity in artificial volume material of water density were performed in nine laboratories with HPGe spectrometry technique. Analysis of the gamma radiation absorption in measured material and in the most important for environmental monitoring substances (food, water, biological materials, soils) confirmed the Compton scattering as the main mechanism of interaction. The list of CMCs supported by the comparison is suggested. (authors)

  11. Final report on COOMET.RI(II)-S2.Cs-137 (319/RU/04): Comparison measurements of radionuclide volume sources (Cs-137)

    Energy Technology Data Exchange (ETDEWEB)

    Korostin, S. [All Russian Research Institute for Physical-Technical and Radio-Technical Measurements (VNIIFTRI), Mendeleevo (Russian Federation); Hernandez, T.; Oropesa, P. [Center of Isotopes - Radionuclide Metrology Department (CENTIS-DMR), Habana (Cuba); Arnold, D. [Physikalisch-Technische Bundesanstalt (PTB), Braunschweig (Germany); Evseev, V. [National Scientific Centre ' Institute of Metrology' (NSC IM), Kharkov (Ukraine); Ivanukovich, A.; Milevskiy, V. [Belarusian State Institute of Metrology (BelGIM), Minsk (Belarus); Svec, A. [Slovak Institute of Metrology (SMU), Bratislava (Slovakia); Lapenas, A. [Latvian National Metrology Centre Ltd, Radiation Metrology and Testing Centre (RMTC), Salaspils (Latvia); Andonova, V. [Bulgarian Institute of Metrology - National Centre of Metrology (BIM-NCM), Sofia (Bulgaria); Steiner, V. [Ministry of the Environment - Radiation and Noise Division (ISR-MoE), Jerusalem (Israel)

    2010-04-15

    Measurements of the Cs-137 specific activity in artificial volume material of water density were performed in nine laboratories with HPGe spectrometry technique. Analysis of the gamma radiation absorption in measured material and in the most important for environmental monitoring substances (food, water, biological materials, soils) confirmed the Compton scattering as the main mechanism of interaction. The list of CMCs supported by the comparison is suggested. (authors)

  12. The Einstein Observatory catalog of IPC x ray sources. Volume 1E: Documentation

    Science.gov (United States)

    Harris, D. E.; Forman, W.; Gioia, I. M.; Hale, J. A.; Harnden, F. R., Jr.; Jones, C.; Karakashian, T.; Maccacaro, T.; Mcsweeney, J. D.; Primini, F. A.

    1993-01-01

    The Einstein Observatory (HEAO-2, launched November 13, 1978) achieved radically improved sensitivity over previous x-ray missions through the use of focusing optics, which simultaneously afforded greatly reduced background and produced true images. During its 2.5-yr mission, the Einstein X-Ray Telescope was pointed toward some 5,000 celestial targets, most of which were detected, and discovered several thousand additional 'serendipitous' sources in the observed fields. This catalog contains contour diagrams and source data, obtained with the imaging proportional counter in the 0.16 to 3.5 keV energy band, and describes methods for recovering upper limits for any sky position within the observed images. The main catalog consists of six volumes (numbered 2 through 7) of right ascension ordered pages, each containing data for one observation. Along with the primary documentation describing how the catalog was constructed, volume 1 contains a complete source list, results for merged fields, a reference system to published papers, and data useful for calculating upper limits and fluxes.

  13. Real-time particle volume fraction measurement in centrifuges by wireless electrical resistance detector

    International Nuclear Information System (INIS)

    Nagae, Fumiya; Okawa, Kazuya; Matsuno, Shinsuke; Takei, Masahiro; Zhao Tong; Ichijo, Noriaki

    2015-01-01

    In this study, wireless electrical resistance detector is developed as first step in order to develop electrical resistance tomography (ERT) that are attached wireless communication, and miniaturized. And the particle volume fraction measurement results appropriateness is qualitatively examined. The real-time particle volume fraction measurement is essential for centrifuges, because rotational velocity and supply should be controlled based on the results in order to obtain the effective separation, shorten process time and save energy. However, a technique for the particle volume fraction measurement in centrifuges has not existed yet. In other words, the real-time particle volume fraction measurement in centrifuges becomes innovative technologies. The experiment device reproduces centrifugation in two-phase using particle and salt solution as measuring object. The particle concentration is measured changing rotational velocity, supply and measurement section position. The measured concentration changes coincide with anticipated tendency of concentration changes. Therefore the particle volume fraction measurement results appropriateness are qualitatively indicated. (author)

  14. Sources and effects of ionizing radiation. UNSCEAR 2000 report to the General Assembly, with scientific annexes. Volume I: Sources

    International Nuclear Information System (INIS)

    2000-01-01

    Over the past few years the United Nations Scientific Committee on the effects of Atomic Radiation has undertaken a broad review of the sources and effects of ionizing radiation. In the present report, the Committee, drawing on the main conclusions of its scientific assessment summarizes the developments in radiation science in the years leading up to the next millennium. It covers the following: the effects of radiation exposure; levels of radiation exposure; radiological consequences of the Chernobyl accident; sources of radiation exposure including natural exposures, man-made environmental exposures, medical and occupational exposures; radiation associated cancer. This volume includes five Annexes covering: dose assessment methodologies; exposure from natural sources; exposures to the public from man-made sources of radiation and occupational radiation exposures

  15. A compact time-of-flight SANS instrument optimised for measurements of small sample volumes at the European Spallation Source

    Energy Technology Data Exchange (ETDEWEB)

    Kynde, Søren, E-mail: kynde@nbi.ku.dk [Niels Bohr Institute, University of Copenhagen (Denmark); Hewitt Klenø, Kaspar [Niels Bohr Institute, University of Copenhagen (Denmark); Nagy, Gergely [SINQ, Paul Scherrer Institute (Switzerland); Mortensen, Kell; Lefmann, Kim [Niels Bohr Institute, University of Copenhagen (Denmark); Kohlbrecher, Joachim, E-mail: Joachim.kohlbrecher@psi.ch [SINQ, Paul Scherrer Institute (Switzerland); Arleth, Lise, E-mail: arleth@nbi.ku.dk [Niels Bohr Institute, University of Copenhagen (Denmark)

    2014-11-11

    The high flux at European Spallation Source (ESS) will allow for performing experiments with relatively small beam-sizes while maintaining a high intensity of the incoming beam. The pulsed nature of the source makes the facility optimal for time-of-flight small-angle neutron scattering (ToF-SANS). We find that a relatively compact SANS instrument becomes the optimal choice in order to obtain the widest possible q-range in a single setting and the best possible exploitation of the neutrons in each pulse and hence obtaining the highest possible flux at the sample position. The instrument proposed in the present article is optimised for performing fast measurements of small scattering volumes, typically down to 2×2×2 mm{sup 3}, while covering a broad q-range from about 0.005 1/Å to 0.5 1/Å in a single instrument setting. This q-range corresponds to that available at a typical good BioSAXS instrument and is relevant for a wide set of biomacromolecular samples. A central advantage of covering the whole q-range in a single setting is that each sample has to be loaded only once. This makes it convenient to use the fully automated high-throughput flow-through sample changers commonly applied at modern synchrotron BioSAXS-facilities. The central drawback of choosing a very compact instrument is that the resolution in terms of δλ/λ obtained with the short wavelength neutrons becomes worse than what is usually the standard at state-of-the-art SANS instruments. Our McStas based simulations of the instrument performance for a set of characteristic biomacromolecular samples show that the resulting smearing effects still have relatively minor effects on the obtained data and can be compensated for in the data analysis. However, in cases where a better resolution is required in combination with the large simultaneous q-range characteristic of the instrument, we show that this can be obtained by inserting a set of choppers.

  16. Monte Carlo Method with Heuristic Adjustment for Irregularly Shaped Food Product Volume Measurement

    Directory of Open Access Journals (Sweden)

    Joko Siswantoro

    2014-01-01

    Full Text Available Volume measurement plays an important role in the production and processing of food products. Various methods have been proposed to measure the volume of food products with irregular shapes based on 3D reconstruction. However, 3D reconstruction comes with a high-priced computational cost. Furthermore, some of the volume measurement methods based on 3D reconstruction have a low accuracy. Another method for measuring volume of objects uses Monte Carlo method. Monte Carlo method performs volume measurements using random points. Monte Carlo method only requires information regarding whether random points fall inside or outside an object and does not require a 3D reconstruction. This paper proposes volume measurement using a computer vision system for irregularly shaped food products without 3D reconstruction based on Monte Carlo method with heuristic adjustment. Five images of food product were captured using five cameras and processed to produce binary images. Monte Carlo integration with heuristic adjustment was performed to measure the volume based on the information extracted from binary images. The experimental results show that the proposed method provided high accuracy and precision compared to the water displacement method. In addition, the proposed method is more accurate and faster than the space carving method.

  17. Monte Carlo method with heuristic adjustment for irregularly shaped food product volume measurement.

    Science.gov (United States)

    Siswantoro, Joko; Prabuwono, Anton Satria; Abdullah, Azizi; Idrus, Bahari

    2014-01-01

    Volume measurement plays an important role in the production and processing of food products. Various methods have been proposed to measure the volume of food products with irregular shapes based on 3D reconstruction. However, 3D reconstruction comes with a high-priced computational cost. Furthermore, some of the volume measurement methods based on 3D reconstruction have a low accuracy. Another method for measuring volume of objects uses Monte Carlo method. Monte Carlo method performs volume measurements using random points. Monte Carlo method only requires information regarding whether random points fall inside or outside an object and does not require a 3D reconstruction. This paper proposes volume measurement using a computer vision system for irregularly shaped food products without 3D reconstruction based on Monte Carlo method with heuristic adjustment. Five images of food product were captured using five cameras and processed to produce binary images. Monte Carlo integration with heuristic adjustment was performed to measure the volume based on the information extracted from binary images. The experimental results show that the proposed method provided high accuracy and precision compared to the water displacement method. In addition, the proposed method is more accurate and faster than the space carving method.

  18. Gastric residual volume (GRV) and gastric contents measurement by refractometry.

    Science.gov (United States)

    Chang, Wei-Kuo; McClave, Stephen A; Hsieh, Chung-Bao; Chao, You-Chen

    2007-01-01

    Traditional use of gastric residual volumes (GRVs), obtained by aspiration from a nasogastric tube, is inaccurate and cannot differentiate components of the gastric contents (gastric secretion vs delivered formula). The use of refractometry and 3 mathematical equations has been proposed as a method to calculate the formula concentration, GRV, and formula volume. In this paper, we have validated these mathematical equations so that they can be implemented in clinical practice. Each of 16 patients receiving a nasogastric tube had 50 mL of water followed by 100 mL of dietary formula (Osmolite HN, Abbott Laboratories, Columbus, OH) infused into the stomach. After mixing, gastric content was aspirated for the first Brix value (BV) measurement by refractometry. Then, 50 mL of water was infused into the stomach and a second BV was measured. The procedure of infusion of dietary formula (100 mL) and then water (50 mL) was repeated and followed by subsequent BV measurement. The same procedure was performed in an in vitro experiment. Formula concentration, GRV, and formula volume were calculated from the derived mathematical equations. The formula concentrations, GRVs, and formula volumes calculated by using refractometry and the mathematical equations were close to the true values obtained from both in vivo and in vitro validation experiments. Using this method, measurement of the BV of gastric contents is simple, reproducible, and inexpensive. Refractometry and the derived mathematical equations may be used to measure formula concentration, GRV, and formula volume, and also to serve as a tool for monitoring the gastric contents of patients receiving nasogastric feeding.

  19. Assessment of volume and leak measurements during CPAP using a neonatal lung model.

    Science.gov (United States)

    Fischer, H S; Roehr, C C; Proquitté, H; Wauer, R R; Schmalisch, G

    2008-01-01

    Although several commercial devices are available which allow tidal volume and air leak monitoring during continuous positive airway pressure (CPAP) in neonates, little is known about their measurement accuracy and about the influence of air leaks on volume measurement. The aim of this in vitro study was the validation of volume and leak measurement under CPAP using a commercial ventilatory device, taking into consideration the clinical conditions in neonatology. The measurement accuracy of the Leoni ventilator (Heinen & Löwenstein, Germany) was investigated both in a leak-free system and with leaks simulated using calibration syringes (2-10 ml, 20-100 ml) and a mechanical lung model. Open tubes of variable lengths were connected for leak simulation. Leak flow was measured with the flow-through technique. In a leak-free system the mean relative volume error +/-SD was 3.5 +/- 2.6% (2-10 ml) and 5.9 +/- 0.7% (20-60 ml), respectively. The influence of CPAP level, driving flow, respiratory rate and humidification of the breathing gas on the volume error was negligible. However, an increasing F(i)O(2) caused the measured tidal volume to increase by up to 25% (F(i)O(2) = 1.0). The relative error +/- SD of the leak measurements was -0.2 +/- 11.9%. For leaks > 19%, measured tidal volume was underestimated by more than 10%. In conclusion, the present in vitro study showed that the Leoni allowed accurate volume monitoring under CPAP conditions similar to neonates. Air leaks of up to 90% of patient flow were reliably detected. For an F(i)O(2) > 0.4 and for leaks > 19%, a numerical correction of the displayed volume should be performed.

  20. Representative volume element of asphalt pavement for electromagnetic measurements

    Directory of Open Access Journals (Sweden)

    Terhi Pellinen

    2015-02-01

    Full Text Available The motivation for this study was to investigate the representative volume element (RVE needed to correlate the nondestructive electromagnetic (EM measurements with the conventional destructive asphalt pavement quality control measurements. A large pavement rehabilitation contract was used as the test site for the experiment. Pavement cores were drilled from the same locations where the stationary and continuous Ground Penetrating Radar (GPR measurements were obtained. Laboratory measurements included testing the bulk density of cores using two methods, the surface-saturated dry method and determining bulk density by dimensions. Also, Vector Network Analyzer (VNA and the through specimen transmission configuration were employed at microwave frequencies to measure the reference dielectric constant of cores using two different footprint areas and therefore volume elements. The RVE for EM measurements turns out to be frequency dependent; therefore in addition to being dependent on asphalt mixture type and method of obtaining bulk density, it is dependent on the resolution of the EM method used. Then, although the average bulk property results agreed with theoretical formulations of higher core air void content giving a lower dielectric constant, for the individual cores there was no correlation for the VNA measurements because the volume element seizes deviated. Similarly, GPR technique was unable to capture the spatial variation of pavement air voids measured from the 150-mm drill cores. More research is needed to determine the usable RVE for asphalt.

  1. High dose rate brachytherapy source measurement intercomparison.

    Science.gov (United States)

    Poder, Joel; Smith, Ryan L; Shelton, Nikki; Whitaker, May; Butler, Duncan; Haworth, Annette

    2017-06-01

    This work presents a comparison of air kerma rate (AKR) measurements performed by multiple radiotherapy centres for a single HDR 192 Ir source. Two separate groups (consisting of 15 centres) performed AKR measurements at one of two host centres in Australia. Each group travelled to one of the host centres and measured the AKR of a single 192 Ir source using their own equipment and local protocols. Results were compared to the 192 Ir source calibration certificate provided by the manufacturer by means of a ratio of measured to certified AKR. The comparisons showed remarkably consistent results with the maximum deviation in measurement from the decay-corrected source certificate value being 1.1%. The maximum percentage difference between any two measurements was less than 2%. The comparisons demonstrated the consistency of well-chambers used for 192 Ir AKR measurements in Australia, despite the lack of a local calibration service, and served as a valuable focal point for the exchange of ideas and dosimetry methods.

  2. Volume measurement variability in three-dimensional high-frequency ultrasound images of murine liver metastases

    International Nuclear Information System (INIS)

    Wirtzfeld, L A; Graham, K C; Groom, A C; MacDonald, I C; Chambers, A F; Fenster, A; Lacefield, J C

    2006-01-01

    The identification and quantification of tumour volume measurement variability is imperative for proper study design of longitudinal non-invasive imaging of pre-clinical mouse models of cancer. Measurement variability will dictate the minimum detectable volume change, which in turn influences the scheduling of imaging sessions and the interpretation of observed changes in tumour volume. In this paper, variability is quantified for tumour volume measurements from 3D high-frequency ultrasound images of murine liver metastases. Experimental B16F1 liver metastases were analysed in different size ranges including less than 1 mm 3 , 1-4 mm 3 , 4-8 mm 3 and 8-70 mm 3 . The intra- and inter-observer repeatability was high over a large range of tumour volumes, but the coefficients of variation (COV) varied over the volume ranges. The minimum and maximum intra-observer COV were 4% and 14% for the 1-4 mm 3 and 3 tumours, respectively. For tumour volumes measured by segmenting parallel planes, the maximum inter-slice distance that maintained acceptable measurement variability increased from 100 to 600 μm as tumour volume increased. Comparison of free breathing versus ventilated animals demonstrated that respiratory motion did not significantly change the measured volume. These results enable design of more efficient imaging studies by using the measured variability to estimate the time required to observe a significant change in tumour volume

  3. Density and volume measurements of reprocessing plant feed

    International Nuclear Information System (INIS)

    Platzer, R.; Carrier, M.; Neuilly, M.; Dedaldechamp, P.

    1985-05-01

    A theoretical study of the phenomenon of gas bubbles formation within a liquid led to an adaptation of the differential pressure bubbling technique for the measurement of liquid levels and densities in tanks. Experiments, carried out on a 800 liters tank with water and uranyl nitrate solutions had the double aim to study the precision attainable on volume and density measurements and to design a method for corrections of influencing factors. In parallel, procedures for transfer of known volumes through the use of siphons and for tank calibration by liquid level measurement are also investigated. The paper presents the first results obtained so far and the conclusions to be drawn for the elaboration of calibration and exploitation procedures suitables for use in reprocessing plants. The demonstration to transfer mass of solution with an accuracy of 0.1% is made [fr

  4. The KamLAND full-volume calibration system

    Energy Technology Data Exchange (ETDEWEB)

    Berger, B E [Department of Physics, Colorado State University, Fort Collins, Colorado 80523 (United States); Busenitz, J; Classen, T; Keefer, G; McKee, D; Piepke, A [Department of Physics and Astronomy, University of Alabama, Tuscaloosa, Alabama 35487 (United States); Decowski, M P; Elor, G; Frank, A; Freedman, S J; Fujikawa, B K; Galloway, M; Gray, F; Hsu, L; Ichimura, K; Kadel, R; Lendvai, C; O' Donnell, T [Physics Department, University of California, Berkeley and Lawrence Berkeley National Laboratory, Berkeley, California 94720 (United States); Dwyer, D A [W. K. Kellogg Radiation Laboratory, California Institute of Technology, Pasadena, California 91125 (United States); Heeger, K M [Department of Physics, University of Wisconsin, Madison, Wisconsin 53706 (United States)] (and others)

    2009-04-15

    We have successfully built and operated a source deployment system for the KamLAND detector. This system was used to position radioactive sources throughout the delicate 1-kton liquid scintillator volume, while meeting stringent material cleanliness, material compatibility, and safety requirements. The calibration data obtained with this device were used to fully characterize detector position and energy reconstruction biases. As a result, the uncertainty in the size of the detector fiducial volume was reduced by a factor of two. Prior to calibration with this system, the fiducial volume was the largest source of systematic uncertainty in measuring the number of antineutrinos detected by KamLAND. This paper describes the design, operation and performance of this unique calibration system.

  5. The KamLAND Full-Volume Calibration System

    Energy Technology Data Exchange (ETDEWEB)

    KamLAND Collaboration; Berger, B. E.; Busenitz, J.; Classen, T.; Decowski, M. P.; Dwyer, D. A.; Elor, G.; Frank, A.; Freedman, S. J.; Fujikawa, B. K.; Galloway, M.; Gray, F.; Heeger, K. M.; Hsu, L.; Ichimura, K.; Kadel, R.; Keefer, G.; Lendvai, C.; McKee, D.; O' Donnell, T.; Piepke, A.; Steiner, H. M.; Syversrud, D.; Wallig, J.; Winslow, L. A.; Ebihara, T.; Enomoto, S.; Furuno, K.; Gando, Y.; Ikeda, H.; Inoue, K.; Kibe, Y.; Kishimoto, Y.; Koga, M.; Minekawa, Y.; Mitsui, T.; Nakajima, K.; Nakajima, K.; Nakamura, K.; Owada, K.; Shimizu, I.; Shimizu, Y.; Shirai, J.; Suekane, F.; Suzuki, A.; Tamae, K.; Yoshida, S.; Kozlov, A.; Murayama, H.; Grant, C.; Leonard, D. S.; Luk, K.-B.; Jillings, C.; Mauger, C.; McKeown, R. D.; Zhang, C.; Lane, C. E.; Maricic, J.; Miletic, T.; Batygov, M.; Learned, J. G.; Matsuno, S.; Pakvasa, S.; Foster, J.; Horton-Smith, G. A.; Tang, A.; Dazeley, S.; Downum, K. E.; Gratta, G.; Tolich, K.; Bugg, W.; Efremenko, Y.; Kamyshkov, Y.; Perevozchikov, O.; Karwowski, H. J.; Markoff, D. M.; Tornow, W.; Piquemal, F.; Ricol, J.-S.

    2009-03-05

    We have successfully built and operated a source deployment system for the KamLAND detector. This system was used to position radioactive sources throughout the delicate 1-kton liquid scintillator volume, while meeting stringent material cleanliness, material compatibility, and safety requirements. The calibration data obtained with this device were used to fully characterize detector position and energy reconstruction biases. As a result, the uncertainty in the size of the detector fiducial volume was reduced by a factor of two. Prior to calibration with this system, the fiducial volume was the largest source of systematic uncertainty in measuring the number of antineutrinos detected by KamLAND. This paper describes the design, operation and performance of this unique calibration system.

  6. Absolute measurement of LDR brachytherapy source emitted power: Instrument design and initial measurements.

    Science.gov (United States)

    Malin, Martha J; Palmer, Benjamin R; DeWerd, Larry A

    2016-02-01

    Energy-based source strength metrics may find use with model-based dose calculation algorithms, but no instruments exist that can measure the energy emitted from low-dose rate (LDR) sources. This work developed a calorimetric technique for measuring the power emitted from encapsulated low-dose rate, photon-emitting brachytherapy sources. This quantity is called emitted power (EP). The measurement methodology, instrument design and performance, and EP measurements made with the calorimeter are presented in this work. A calorimeter operating with a liquid helium thermal sink was developed to measure EP from LDR brachytherapy sources. The calorimeter employed an electrical substitution technique to determine the power emitted from the source. The calorimeter's performance and thermal system were characterized. EP measurements were made using four (125)I sources with air-kerma strengths ranging from 2.3 to 5.6 U and corresponding EPs of 0.39-0.79 μW, respectively. Three Best Medical 2301 sources and one Oncura 6711 source were measured. EP was also computed by converting measured air-kerma strengths to EPs through Monte Carlo-derived conversion factors. The measured EP and derived EPs were compared to determine the accuracy of the calorimeter measurement technique. The calorimeter had a noise floor of 1-3 nW and a repeatability of 30-60 nW. The calorimeter was stable to within 5 nW over a 12 h measurement window. All measured values agreed with derived EPs to within 10%, with three of the four sources agreeing to within 4%. Calorimeter measurements had uncertainties ranging from 2.6% to 4.5% at the k = 1 level. The values of the derived EPs had uncertainties ranging from 2.9% to 3.6% at the k = 1 level. A calorimeter capable of measuring the EP from LDR sources has been developed and validated for (125)I sources with EPs between 0.43 and 0.79 μW.

  7. Measurement of Crystalline Lens Volume During Accommodation in a Lens Stretcher.

    Science.gov (United States)

    Marussich, Lauren; Manns, Fabrice; Nankivil, Derek; Maceo Heilman, Bianca; Yao, Yue; Arrieta-Quintero, Esdras; Ho, Arthur; Augusteyn, Robert; Parel, Jean-Marie

    2015-07-01

    To determine if the lens volume changes during accommodation. The study used data acquired on 36 cynomolgus monkey lenses that were stretched in a stepwise fashion to simulate disaccommodation. At each step, stretching force and dioptric power were measured and a cross-sectional image of the lens was acquired using an optical coherence tomography system. Images were corrected for refractive distortions and lens volume was calculated assuming rotational symmetry. The average change in lens volume was calculated and the relation between volume change and power change, and between volume change and stretching force, were quantified. Linear regressions of volume-power and volume-force plots were calculated. The mean (± SD) volume in the unstretched (accommodated) state was 97 ± 8 mm3. On average, there was a small but statistically significant (P = 0.002) increase in measured lens volume with stretching. The mean change in lens volume was +0.8 ± 1.3 mm3. The mean volume-power and volume-load slopes were -0.018 ± 0.058 mm3/D and +0.16 ± 0.40 mm3/g. Lens volume remains effectively constant during accommodation, with changes that are less than 1% on average. This result supports a hypothesis that the change in lens shape with accommodation is accompanied by a redistribution of tissue within the capsular bag without significant compression of the lens contents or fluid exchange through the capsule.

  8. Liquid volumes measurements by isotopic dilution

    International Nuclear Information System (INIS)

    Herrera M, J.M.

    1981-01-01

    By the nuclear technique, isotopic dilution industrial liquid volumes may be measured in large size recipients of irregular shapes using radiotracers. In the present work laboratory and pilot test are made with 2 radiotracers for optimizing the technique and later done on an industrial scale, obtaining a maximum deviation of +-2%, some recommendations are given to improve the performance of the technique. (author)

  9. Assessment of volume and leak measurements during CPAP using a neonatal lung model

    International Nuclear Information System (INIS)

    Fischer, H S; Roehr, C C; Proquitté, H; Wauer, R R; Schmalisch, G

    2008-01-01

    Although several commercial devices are available which allow tidal volume and air leak monitoring during continuous positive airway pressure (CPAP) in neonates, little is known about their measurement accuracy and about the influence of air leaks on volume measurement. The aim of this in vitro study was the validation of volume and leak measurement under CPAP using a commercial ventilatory device, taking into consideration the clinical conditions in neonatology. The measurement accuracy of the Leoni ventilator (Heinen and Löwenstein, Germany) was investigated both in a leak-free system and with leaks simulated using calibration syringes (2–10 ml, 20–100 ml) and a mechanical lung model. Open tubes of variable lengths were connected for leak simulation. Leak flow was measured with the flow-through technique. In a leak-free system the mean relative volume error ±SD was 3.5 ± 2.6% (2–10 ml) and 5.9 ± 0.7% (20–60 ml), respectively. The influence of CPAP level, driving flow, respiratory rate and humidification of the breathing gas on the volume error was negligible. However, an increasing F i O 2 caused the measured tidal volume to increase by up to 25% (F i O 2 = 1.0). The relative error ±SD of the leak measurements was −0.2 ± 11.9%. For leaks >19%, measured tidal volume was underestimated by more than 10%. In conclusion, the present in vitro study showed that the Leoni allowed accurate volume monitoring under CPAP conditions similar to neonates. Air leaks of up to 90% of patient flow were reliably detected. For an F i O 2 >0.4 and for leaks >19%, a numerical correction of the displayed volume should be performed

  10. Measuring stone volume - three-dimensional software reconstruction or an ellipsoid algebra formula?

    Science.gov (United States)

    Finch, William; Johnston, Richard; Shaida, Nadeem; Winterbottom, Andrew; Wiseman, Oliver

    2014-04-01

    To determine the optimal method for assessing stone volume, and thus stone burden, by comparing the accuracy of scalene, oblate, and prolate ellipsoid volume equations with three-dimensional (3D)-reconstructed stone volume. Kidney stone volume may be helpful in predicting treatment outcome for renal stones. While the precise measurement of stone volume by 3D reconstruction can be accomplished using modern computer tomography (CT) scanning software, this technique is not available in all hospitals or with routine acute colic scanning protocols. Therefore, maximum diameters as measured by either X-ray or CT are used in the calculation of stone volume based on a scalene ellipsoid formula, as recommended by the European Association of Urology. In all, 100 stones with both X-ray and CT (1-2-mm slices) were reviewed. Complete and partial staghorn stones were excluded. Stone volume was calculated using software designed to measure tissue density of a certain range within a specified region of interest. Correlation coefficients among all measured outcomes were compared. Stone volumes were analysed to determine the average 'shape' of the stones. The maximum stone diameter on X-ray was 3-25 mm and on CT was 3-36 mm, with a reasonable correlation (r = 0.77). Smaller stones (15 mm towards scalene ellipsoids. There was no difference in stone shape by location within the kidney. As the average shape of renal stones changes with diameter, no single equation for estimating stone volume can be recommended. As the maximum diameter increases, calculated stone volume becomes less accurate, suggesting that larger stones have more asymmetric shapes. We recommend that research looking at stone clearance rates should use 3D-reconstructed stone volumes when available, followed by prolate, oblate, or scalene ellipsoid formulas depending on the maximum stone diameter. © 2013 The Authors. BJU International © 2013 BJU International.

  11. Volume measurement of the leg with the depth camera for quantitative evaluation of edema

    Science.gov (United States)

    Kiyomitsu, Kaoru; Kakinuma, Akihiro; Takahashi, Hiroshi; Kamijo, Naohiro; Ogawa, Keiko; Tsumura, Norimichi

    2017-02-01

    Volume measurement of the leg is important in the evaluation of leg edema. Recently, method for measurement by using a depth camera is proposed. However, many depth cameras are expensive. Therefore, we propose a method using Microsoft Kinect. We obtain a point cloud of the leg by Kinect Fusion technique and calculate the volume. We measured the volume of leg for three healthy students during three days. In each measurement, the increase of volume was confirmed from morning to evening. It is known that the volume of leg is increased in doing office work. Our experimental results meet this expectation.

  12. Accurate shear measurement with faint sources

    International Nuclear Information System (INIS)

    Zhang, Jun; Foucaud, Sebastien; Luo, Wentao

    2015-01-01

    For cosmic shear to become an accurate cosmological probe, systematic errors in the shear measurement method must be unambiguously identified and corrected for. Previous work of this series has demonstrated that cosmic shears can be measured accurately in Fourier space in the presence of background noise and finite pixel size, without assumptions on the morphologies of galaxy and PSF. The remaining major source of error is source Poisson noise, due to the finiteness of source photon number. This problem is particularly important for faint galaxies in space-based weak lensing measurements, and for ground-based images of short exposure times. In this work, we propose a simple and rigorous way of removing the shear bias from the source Poisson noise. Our noise treatment can be generalized for images made of multiple exposures through MultiDrizzle. This is demonstrated with the SDSS and COSMOS/ACS data. With a large ensemble of mock galaxy images of unrestricted morphologies, we show that our shear measurement method can achieve sub-percent level accuracy even for images of signal-to-noise ratio less than 5 in general, making it the most promising technique for cosmic shear measurement in the ongoing and upcoming large scale galaxy surveys

  13. Measuring radon source magnitude in residential buildings

    International Nuclear Information System (INIS)

    Nazaroff, W.W.; Boegel, M.L.; Nero, A.V.

    1981-08-01

    A description is given of procedures used in residences for rapid grab-sample and time-dependent measurements of the air-exchange rate and radon concentration. The radon source magnitude is calculated from the results of simultaneous measurements of these parameters. Grab-sample measurements in three survey groups comprising 101 US houses showed the radon source magnitude to vary approximately log-normally with a geometric mean of 0.37 and a range of 0.01 to 6.0 pCi 1 -1 h -1 . Successive measurements in six houses in the northeastern United States showed considerable variability in source magnitude within a given house. In two of these houses the source magnitude showed a strong correlation with the air-exchange rate, suggesting that soil gas influx can be an important transport process for indoor radon

  14. Are tidal volume measurements in neonatal pressure-controlled ventilation accurate?

    Science.gov (United States)

    Chow, Lily C; Vanderhal, Andre; Raber, Jorge; Sola, Augusto

    2002-09-01

    Bedside pulmonary mechanics monitors (PMM) have become useful in ventilatory management in neonates. These monitors are used more frequently due to recent improvements in data-processing capabilities. PMM devices are often part of the ventilator or are separate units. The accuracy and reliability of these systems have not been carefully evaluated. We compared a single ventilatory parameter, tidal volume (V(t)), as measured by several systems. We looked at two freestanding PMMs: the Ventrak Respiratory Monitoring System (Novametrix, Wallingford, CT) and the Bicore CP-100 Neonatal Pulmonary Monitor (Allied Health Care Products, Riverside, CA), and three ventilators with built-in PMM: the VIP Bird Ventilator (Bird Products Corp., Palm Springs, CA), Siemens Servo 300A (Siemens-Elema AB, Solna, Sweden), and Drager Babylog 8000 (Drager, Inc., Chantilly, VA). A calibrated syringe (Hans Rudolph, Inc., Kansas City, MO) was used to deliver tidal volumes of 4, 10, and 20 mL to each ventilator system coupled with a freestanding PMM. After achieving steady state, six consecutive V(t) readings were taken simultaneously from the freestanding PMM and each ventilator. In a second portion of the bench study, we used pressure-control ventilation and measured exhaled tidal volume (V(te)) while ventilating a Bear Test Lung with the same three ventilators. We adjusted peak inspiratory pressure (PIP) under controlled conditions to achieve the three different targeted tidal volumes on the paired freestanding PMM. Again, six V(te) measurements were recorded for each tidal volume. Means and standard deviations were calculated.The percentage difference in measurement of V(t) delivered by calibrated syringe varied greatly, with the greatest discrepancy seen in the smallest tidal volumes, by up to 28%. In pressure control mode, V(te) as measured by the Siemens was significantly overestimated by 20-95%, with the biggest discrepancy at the smallest V(te), particularly when paired with the Bicore

  15. Measurements of magnetic field sources in schools

    International Nuclear Information System (INIS)

    Johnson, G.B.

    1992-01-01

    The Electrical Systems Division of the Electric Power Research Institute (EPRI) has initiated several research projects to investigate magnetic field levels, their characteristics, and their sources. This paper describes measurements of magnetic field sources in schools. Magnetic field measurements were made at four schools in the service areas of two utility companies. Magnetic field measurements included profiles of the magnetic field versus distance near power lines, around the perimeter of the school buildings, and at several locations within each school. Twenty-four hour measurements were also made to record the temporal variation of the magnetic field at several locations at each school. The instrumentation, measurement techniques, and magnetic field sources identified are discussed

  16. Numerical simulation of homogenization time measurement by probes with different volume size

    International Nuclear Information System (INIS)

    Thyn, J.; Novy, M.; Zitny, R.; Mostek, M.; Jahoda, M.

    2004-01-01

    Results of continuous homogenization time measurement of liquid in a stirred tank depend on the scale of scrutiny. Experimental techniques use a probe, which is situated inside as a conductivity method, or outside of the tank as in the case of gamma-radiotracer methods. Expected value of homogenization time evaluated for a given degree of homogenization is higher when using the conductivity method because the conductivity probe measures relatively small volume in contrast to application of radiotracer, when the volume is much greater. Measurement through the wall of tank is a great advantage of radiotracer application but a comparison of the results with another method supposes a determination of measured volume, which is not easy. Simulation of measurement by CFD code can help to solve the problem. Methodology for CFD simulation of radiotracer experiments was suggested. Commercial software was used for simulation of liquid homogenization in mixed vessel with Rushton turbine. Numerical simulation of liquid homogenization time by CFD for different values of detected volume was confronted with measurement of homogenization time with conductivity probe and with different radioisotopes 198 Au, 82 Br and 24 Na. Detected size of the tank volume was affected by different energy of radioisotope used. (author)

  17. Clinical significance of measurement of hepatic volume by computed tomography

    International Nuclear Information System (INIS)

    Sato, Hiroyuki; Matsuda, Yoshiro; Takada, Akira

    1984-01-01

    Hepatic volumes were measured by computed tomography (CT) in 91 patients with chronic liver diseases. Mean hepatic volume in alcoholic liver disease was significantly larger than that in non-alcoholic liver disease. Hepatic volumes in the majority of decompensated liver cirrhosis were significantly smaller than those of compensated liver cirrhosis. In liver cirrhosis, significant correlations between hepatic volume and various hepatic tests which reflect the total functioning hepatic cell masses were found. Combinations of hepatic volume with ICG maximum removal rate and with serum cholinesterase activity were most useful for the assessment of prognosis in liver cirrhosis. These results indicated that estimation of hepatic volume by CT is useful for analysis of pathophysiology and prognosis of chronic liver diseases, and for diagnosis of alcoholic liver diseases. (author)

  18. Construction and operation of the Spallation Neutron Source: Draft environmental impact statement. Volume 2

    International Nuclear Information System (INIS)

    1998-12-01

    DOE proposes to construct and operate a state-of-the-art, short-pulsed spallation neutron source comprised of an ion source, a linear accelerator, a proton accumulator ring, and an experiment building containing a liquid mercury target and a suite of neutron scattering instrumentation. The proposed Spallation Neutron Source would be designed to operate at a proton beam power of 1 megawatt. The design would accommodate future upgrades to a peak operating power of 4 megawatts. These upgrades may include construction of a second proton accumulation ring and a second target. Volume 1 of this document analyzes the potential environmental impacts from the proposed action and the alternatives. The analysis assumes a facility operating at a power of 1 MW and 4 MW over the life of the facility. The two primary alternatives analyzed in this EIS are: the proposed action (to proceed with building the Spallation Neutron Source) and the No-Action Alternative. This volume contains the following appendices: (A) SNS accident source terms for EIS input; (B) Reports on the selection of alternative sites for the SNS; (C) Letters of consultation on protected species and cultural resources; (D) Ecological resource survey reports and summaries; (E) Descriptions of ORNL research projects in the Walker Branch Watershed; (F) Atmospheric dispersion and dose calculations for normal and accident conditions; (G) Projected air quality modeling effects at NOAA's Walker Branch Monitoring Tower

  19. High-speed volume measurement system

    Energy Technology Data Exchange (ETDEWEB)

    Lane, Michael H.; Doyle, Jr., James L.; Brinkman, Michael J.

    2018-01-30

    Disclosed is a volume sensor having a first axis, a second axis, and a third axis, each axis including a laser source configured to emit a beam; a parallel beam generating assembly configured to receive the beam and split the beam into a first parallel beam and a second parallel beam, a beam-collimating assembly configured to receive the first parallel beam and the second parallel beam and output a first beam sheet and a second beam sheet, the first beam sheet and the second beam sheet being configured to traverse the object aperture; a first collecting lens and a second collecting lens; and a first photodetector and a second photodetector, the first photodetector and the second photodetector configured to output an electrical signal proportional to the object; wherein the first axis, the second axis, and the third axis are arranged at an angular offset with respect to each other.

  20. MRI volume measurement of the brain in schizophrenia

    International Nuclear Information System (INIS)

    Someya, Yasuhiro; Abe, Tetsuo; Asai, Kunihiko; Okubo, Yoshirou; Toru, Michio.

    1996-01-01

    The T1-weighted images of whole-brain three-dimensional MRI (thickness, 3 mm; interval, 3 mm) were obtained from schizophrenic patients and 20 healthy volunteers. Detailed volumetric measurement of each part in the brain was carried out. As the result, the volume of both ventricles and third ventriculus cerebri in the schizophrenic group was significantly larger than that of the control group. No significant difference was observed in terms of the volume of the bilateral frontal lobe, bilateral body of caudate nucleus division and right temporal lobe. The volume of bilateral hippocampus and left temporal lobe of the schizophrenic group was significantly smaller than that of the control group. Negative correlation was observed between symptoms and the right temporal lobe volume (r=-0.41) in the schizophrenic group. In the schizophrenic group, morphological abnormality was admitted in the hippocampus, ventriculus cerebri and left temporal lobe. The morphological abnormality of the right temporal lobe seemed to involve the expression of negative symptoms. (S.Y.)

  1. Influence of tube volume on measurement uncertainty of GM counters

    Directory of Open Access Journals (Sweden)

    Stanković Koviljka Đ.

    2010-01-01

    Full Text Available GM counters are often used in radiation detection since they generate a strong signal which can be easily detected. The working principal of a GM counter is based on the interaction of ionizing radiation with the atoms and molecules of the gas present in the counter's tube. Free electrons created as a result of this interaction become initial electrons, i. e. start an avalanche process which is detected as a pulse of current. This current pulse is independent of the energy imparted on the gas, that being the main difference between a GM counter and the majority of other radiation detectors. In literature, the dependence on the incidence of radiation energy, tube's orientation and characteristics of the reading system are quoted as the main sources of measurement uncertainty of GM counters. The aim of this paper is to determine the dependence of measurement uncertainty of a GM counter on the volume of its counter's tube. The dependence of the pulse current on the size of the counter's tube has, therefore, been considered here, both in radial and parallel geometry. The initiation and expansion of the current pulse have been examined by means of elementary processes of electrical discharge such as the Markov processes, while the changes in the counter's tube volume were put to test by the space - time enlargement law. The random variable known as the 'current pulse in the counter's tube' (i. e. electrical breakdown of the electrode configuration has also been taken into account and an appropriate theoretical distribution statistically determined. Thus obtained theoretical results were then compared to corresponding experimental results established in controlled laboratory conditions.

  2. Study of accurate volume measurement system for plutonium nitrate solution

    Energy Technology Data Exchange (ETDEWEB)

    Hosoma, T. [Power Reactor and Nuclear Fuel Development Corp., Tokai, Ibaraki (Japan). Tokai Works

    1998-12-01

    It is important for effective safeguarding of nuclear materials to establish a technique for accurate volume measurement of plutonium nitrate solution in accountancy tank. The volume of the solution can be estimated by two differential pressures between three dip-tubes, in which the air is purged by an compressor. One of the differential pressure corresponds to the density of the solution, and another corresponds to the surface level of the solution in the tank. The measurement of the differential pressure contains many uncertain errors, such as precision of pressure transducer, fluctuation of back-pressure, generation of bubbles at the front of the dip-tubes, non-uniformity of temperature and density of the solution, pressure drop in the dip-tube, and so on. The various excess pressures at the volume measurement are discussed and corrected by a reasonable method. High precision-differential pressure measurement system is developed with a quartz oscillation type transducer which converts a differential pressure to a digital signal. The developed system is used for inspection by the government and IAEA. (M. Suetake)

  3. Radiologic measurement of extraocular muscle volumes in patients with Graves' orbitopathy: a review and guideline.

    Science.gov (United States)

    Bijlsma, Ward R; Mourits, Maarten Ph

    2006-06-01

    To evaluate and compare techniques for extraocular muscle (EOM) volume measurement and to provide guidelines for future measurements. Systematic review. Existing techniques used to measure extraocular muscle volumes on radiologic scans can be divided into manual outlining, computer assisted and automated segmentation. Both computed tomography (CT) and magnetic resonance (MR) image datasets can be used. On CT scans, one best measures muscle volume using region grow segmentation, accepting an overestimation of true volume by inevitable inclusion of non-muscular tissue. On high resolution MRI scans, single muscles can be outlined manually, but measurements include only part of the muscle due to poor tissue contrast at the orbital apex. Measurement errors can be reduced 3.5% by exact horizontal repositioning. A measured volume change of at least 6-17% is required to demonstrate a significant difference. Currently the best choice for EOM volume measurements on CT images is computer assisted grey value segmentation and on MRI images is manual outlining of individual muscles. Because of the time required and the complexity of the measurements, present EOM volume measurement is as yet only suitable for research purposes.

  4. Volume of Structures in the Fetal Brain Measured with a New Semiautomated Method.

    Science.gov (United States)

    Ber, R; Hoffman, D; Hoffman, C; Polat, A; Derazne, E; Mayer, A; Katorza, E

    2017-11-01

    Measuring the volume of fetal brain structures is challenging due to fetal motion, low resolution, and artifacts caused by maternal tissue. Our aim was to introduce a new, simple, Matlab-based semiautomated method to measure the volume of structures in the fetal brain and present normal volumetric curves of the structures measured. The volume of the supratentorial brain, left and right hemispheres, cerebellum, and left and right eyeballs was measured retrospectively by the new semiautomated method in MR imaging examinations of 94 healthy fetuses. Four volume ratios were calculated. Interobserver agreement was calculated with the intraclass correlation coefficient, and a Bland-Altman plot was drawn for comparison of manual and semiautomated method measurements of the supratentorial brain. We present normal volumetric curves and normal percentile values of the structures measured according to gestational age and of the ratios between the cerebellum and the supratentorial brain volume and the total eyeball and the supratentorial brain volume. Interobserver agreement was good or excellent for all structures measured. The Bland-Altman plot between manual and semiautomated measurements showed a maximal relative difference of 7.84%. We present a technologically simple, reproducible method that can be applied prospectively and retrospectively on any MR imaging protocol, and we present normal volumetric curves measured. The method shows results like manual measurements while being less time-consuming and user-dependent. By applying this method on different cranial and extracranial structures, anatomic and pathologic, we believe that fetal volumetry can turn from a research tool into a practical clinical one. © 2017 by American Journal of Neuroradiology.

  5. Evaluation of the accuracy of ventricular volume measurement by ultrafast CT

    International Nuclear Information System (INIS)

    Cui Wei; Dai Ruping; Guo Yuyin

    1997-01-01

    The authors evaluated the accuracy of ventricular volume measured by ultrafast CT (UFCT); and (2) compared the value of ventricular volume derived from long- and short-axis view. Fourteen human left ventricular casts and 15 right ventricular casts were scanned by Imatron C-150 scanner along both the long- and short-axis. The scan protocol was similar to that used in vivo. Eight 7 mm-thick slices were obtained from each cast for both long- and short-axis views. Ventricular volume was determined by the modified Simpson's rule provided by Inamtron Inc. The actual volumes of the ventricular casts were determined by the amount of water displacement by the cast. The actual volumes for left and right ventricles were 55.57 +- 28.91 ml and 64.23 +- 24.51 ml, respectively, the left and right ventricular volumes determined by UFCT were 66.50 +- 33.04 ml and 76.47 +-28.70 ml from long-axis view, and 60.36 +- 29.90 ml and 75.36 +- 28.73 ml from short-axis view, respectively. The measurements by UFCT were significantly greater than the actual volumes of the casts, both for the left and right ventricles (P 0.990). Both left and right ventricular volumes can be determined by UFCT with identical accuracy for both long- and short-axis views in calculating ventricular volume; however, overestimation of ventricular volume by UFCT should be noted

  6. Adrenal gland volume measurement in septic shock and control patients: a pilot study

    Energy Technology Data Exchange (ETDEWEB)

    Nougaret, Stephanie; Aufort, S.; Gallix, B. [Hopital Saint Eloi, Department of Abdominal Imaging, CHU Montpellier, Montpellier, Cedex 5 (France); Jung, B.; Chanques, G.; Jaber, S. [Hopital Saint Eloi, Intensive Care Unit, Department of Critical Care and Anesthesiology: DAR B, CHU Montpellier, Montpellier, Cedex 5 (France)

    2010-10-15

    To compare adrenal gland volume in septic shock patients and control patients by using semi-automated volumetry. Adrenal gland volume and its inter-observer variability were measured with tomodensitometry using semi-automated software in 104 septic shock patients and in 40 control patients. The volumes of control and septic shock patients were compared and the relationship between volume and outcome in intensive care was studied. The mean total volume of both adrenal glands was 7.2 {+-} 2.0 cm{sup 3} in control subjects and 13.3 {+-} 4.7 cm{sup 3} for total adrenal gland volume in septic shock patients (p < 0.0001). Measurement reproducibility was excellent with a concordance correlation coefficient value of 0.87. The increasing adrenal gland volume was associated with a higher rate of survival in intensive care. The present study reports that with semi-automated software, adrenal gland volume can be measured easily and reproducibly. Adrenal gland volume was found to be nearly double in sepsis compared with control patients. The absence of increased volume during sepsis would appear to be associated with a higher rate of mortality and may represent a prognosis factor which may help the clinician to guide their strategy. (orig.)

  7. Adrenal gland volume measurement in septic shock and control patients: a pilot study

    International Nuclear Information System (INIS)

    Nougaret, Stephanie; Aufort, S.; Gallix, B.; Jung, B.; Chanques, G.; Jaber, S.

    2010-01-01

    To compare adrenal gland volume in septic shock patients and control patients by using semi-automated volumetry. Adrenal gland volume and its inter-observer variability were measured with tomodensitometry using semi-automated software in 104 septic shock patients and in 40 control patients. The volumes of control and septic shock patients were compared and the relationship between volume and outcome in intensive care was studied. The mean total volume of both adrenal glands was 7.2 ± 2.0 cm 3 in control subjects and 13.3 ± 4.7 cm 3 for total adrenal gland volume in septic shock patients (p < 0.0001). Measurement reproducibility was excellent with a concordance correlation coefficient value of 0.87. The increasing adrenal gland volume was associated with a higher rate of survival in intensive care. The present study reports that with semi-automated software, adrenal gland volume can be measured easily and reproducibly. Adrenal gland volume was found to be nearly double in sepsis compared with control patients. The absence of increased volume during sepsis would appear to be associated with a higher rate of mortality and may represent a prognosis factor which may help the clinician to guide their strategy. (orig.)

  8. Indirect measurement of lung density and air volume from electrical impedance tomography (EIT) data.

    Science.gov (United States)

    Nebuya, Satoru; Mills, Gary H; Milnes, Peter; Brown, Brian H

    2011-12-01

    This paper describes a method for estimating lung density, air volume and changes in fluid content from a non-invasive measurement of the electrical resistivity of the lungs. Resistivity in Ω m was found by fitting measured electrical impedance tomography (EIT) data to a finite difference model of the thorax. Lung density was determined by comparing the resistivity of the lungs, measured at a relatively high frequency, with values predicted from a published model of lung structure. Lung air volume can then be calculated if total lung weight is also known. Temporal changes in lung fluid content will produce proportional changes in lung density. The method was implemented on EIT data, collected using eight electrodes placed in a single plane around the thorax, from 46 adult male subjects and 36 adult female subjects. Mean lung densities (±SD) of 246 ± 67 and 239 ± 64 kg m(-3), respectively, were obtained. In seven adult male subjects estimates of 1.68 ± 0.30, 3.42 ± 0.49 and 4.40 ± 0.53 l in residual volume, functional residual capacity and vital capacity, respectively, were obtained. Sources of error are discussed. It is concluded that absolute differences in lung density of about 30% and changes over time of less than 30% should be detected using the current technology in normal subjects. These changes would result from approximately 300 ml increase in lung fluid. The method proposed could be used for non-invasive monitoring of total lung air and fluid content in normal subjects but needs to be assessed in patients with lung disease.

  9. The preliminary exploration of 64-slice volume computed tomography in the accurate measurement of pleural effusion.

    Science.gov (United States)

    Guo, Zhi-Jun; Lin, Qiang; Liu, Hai-Tao; Lu, Jun-Ying; Zeng, Yan-Hong; Meng, Fan-Jie; Cao, Bin; Zi, Xue-Rong; Han, Shu-Ming; Zhang, Yu-Huan

    2013-09-01

    Using computed tomography (CT) to rapidly and accurately quantify pleural effusion volume benefits medical and scientific research. However, the precise volume of pleural effusions still involves many challenges and currently does not have a recognized accurate measuring. To explore the feasibility of using 64-slice CT volume-rendering technology to accurately measure pleural fluid volume and to then analyze the correlation between the volume of the free pleural effusion and the different diameters of the pleural effusion. The 64-slice CT volume-rendering technique was used to measure and analyze three parts. First, the fluid volume of a self-made thoracic model was measured and compared with the actual injected volume. Second, the pleural effusion volume was measured before and after pleural fluid drainage in 25 patients, and the volume reduction was compared with the actual volume of the liquid extract. Finally, the free pleural effusion volume was measured in 26 patients to analyze the correlation between it and the diameter of the effusion, which was then used to calculate the regression equation. After using the 64-slice CT volume-rendering technique to measure the fluid volume of the self-made thoracic model, the results were compared with the actual injection volume. No significant differences were found, P = 0.836. For the 25 patients with drained pleural effusions, the comparison of the reduction volume with the actual volume of the liquid extract revealed no significant differences, P = 0.989. The following linear regression equation was used to compare the pleural effusion volume (V) (measured by the CT volume-rendering technique) with the pleural effusion greatest depth (d): V = 158.16 × d - 116.01 (r = 0.91, P = 0.000). The following linear regression was used to compare the volume with the product of the pleural effusion diameters (l × h × d): V = 0.56 × (l × h × d) + 39.44 (r = 0.92, P = 0.000). The 64-slice CT volume-rendering technique can

  10. The preliminary exploration of 64-slice volume computed tomography in the accurate measurement of pleural effusion

    International Nuclear Information System (INIS)

    Guo, Zhi-Jun; Lin, Qiang; Liu, Hai-Tao

    2013-01-01

    Background: Using computed tomography (CT) to rapidly and accurately quantify pleural effusion volume benefits medical and scientific research. However, the precise volume of pleural effusions still involves many challenges and currently does not have a recognized accurate measuring. Purpose: To explore the feasibility of using 64-slice CT volume-rendering technology to accurately measure pleural fluid volume and to then analyze the correlation between the volume of the free pleural effusion and the different diameters of the pleural effusion. Material and Methods: The 64-slice CT volume-rendering technique was used to measure and analyze three parts. First, the fluid volume of a self-made thoracic model was measured and compared with the actual injected volume. Second, the pleural effusion volume was measured before and after pleural fluid drainage in 25 patients, and the volume reduction was compared with the actual volume of the liquid extract. Finally, the free pleural effusion volume was measured in 26 patients to analyze the correlation between it and the diameter of the effusion, which was then used to calculate the regression equation. Results: After using the 64-slice CT volume-rendering technique to measure the fluid volume of the self-made thoracic model, the results were compared with the actual injection volume. No significant differences were found, P = 0.836. For the 25 patients with drained pleural effusions, the comparison of the reduction volume with the actual volume of the liquid extract revealed no significant differences, P = 0.989. The following linear regression equation was used to compare the pleural effusion volume (V) (measured by the CT volume-rendering technique) with the pleural effusion greatest depth (d): V = 158.16 X d - 116.01 (r = 0.91, P = 0.000). The following linear regression was used to compare the volume with the product of the pleural effusion diameters (l X h X d): V = 0.56 X (l X h X d) + 39.44 (r = 0.92, P = 0

  11. The preliminary exploration of 64-slice volume computed tomography in the accurate measurement of pleural effusion

    Energy Technology Data Exchange (ETDEWEB)

    Guo, Zhi-Jun [Dept. of Radiology, North China Petroleum Bureau General Hospital, Renqiu, Hebei (China)], e-mail: Gzj3@163.com; Lin, Qiang [Dept. of Oncology, North China Petroleum Bureau General Hospital, Renqiu, Hebei (China); Liu, Hai-Tao [Dept. of General Surgery, North China Petroleum Bureau General Hospital, Renqiu, Hebei (China)] [and others])

    2013-09-15

    Background: Using computed tomography (CT) to rapidly and accurately quantify pleural effusion volume benefits medical and scientific research. However, the precise volume of pleural effusions still involves many challenges and currently does not have a recognized accurate measuring. Purpose: To explore the feasibility of using 64-slice CT volume-rendering technology to accurately measure pleural fluid volume and to then analyze the correlation between the volume of the free pleural effusion and the different diameters of the pleural effusion. Material and Methods: The 64-slice CT volume-rendering technique was used to measure and analyze three parts. First, the fluid volume of a self-made thoracic model was measured and compared with the actual injected volume. Second, the pleural effusion volume was measured before and after pleural fluid drainage in 25 patients, and the volume reduction was compared with the actual volume of the liquid extract. Finally, the free pleural effusion volume was measured in 26 patients to analyze the correlation between it and the diameter of the effusion, which was then used to calculate the regression equation. Results: After using the 64-slice CT volume-rendering technique to measure the fluid volume of the self-made thoracic model, the results were compared with the actual injection volume. No significant differences were found, P = 0.836. For the 25 patients with drained pleural effusions, the comparison of the reduction volume with the actual volume of the liquid extract revealed no significant differences, P = 0.989. The following linear regression equation was used to compare the pleural effusion volume (V) (measured by the CT volume-rendering technique) with the pleural effusion greatest depth (d): V = 158.16 X d - 116.01 (r = 0.91, P = 0.000). The following linear regression was used to compare the volume with the product of the pleural effusion diameters (l X h X d): V = 0.56 X (l X h X d) + 39.44 (r = 0.92, P = 0

  12. Measurement of normal ocular volume by the use of computed ...

    African Journals Online (AJOL)

    Background: Reduction or increase in ocular volume may indicate ocular pathology. Unfortunately the reference values utilized for ocular volume had been that of non-Africans. It is therefore pertinent to have a reference value of normal for Africans. Objective: To document the computer tomography (CT) scan measured ...

  13. Intense Pulsed Neutron Source: Progress report 1991--1996. 15. Anniversary edition -- Volume 1

    Energy Technology Data Exchange (ETDEWEB)

    Marzec, B. [ed.

    1996-05-01

    The 15th Anniversary Edition of the IPNS Progress Report is being published in recognition of the Intense Pulsed Neutron Source`s first 15 years of successful operation as a user facility. To emphasize the importance of this milestone, the authors have made the design and organization of the report significantly different from previous IPNS Progress Reports. This report consists of two volumes. For Volume 1, authors were asked to prepare articles that highlighted recent scientific accomplishments at IPNS, from 1991 to present; to focus on and illustrate the scientific advances achieved through the unique capabilities of neutron studies performed by IPNS users; to report on specific activities or results from an instrument; or to focus on a body of work encompassing different neutron-scattering techniques. Articles were also included on the accelerator system, instrumentation, computing, target, and moderators. A list of published and ``in press` articles in journals, books, and conference proceedings, resulting from work done at IPNS since 1991, was compiled. This list is arranged alphabetically according to first author. Publication references in the articles are listed by last name of first author and year of publication. The IPNS experimental reports received since 1991 are compiled in Volume 2. Experimental reports referenced in the articles are listed by last name of first author, instrument designation, and experiment number.

  14. Intense Pulsed Neutron Source: Progress report 1991--1996. 15. Anniversary edition -- Volume 2

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-05-01

    The 15th Anniversary Edition of the IPNS Progress Report is being published in recognition of the Intense Pulsed Neutron Source`s first 15 years of successful operation as a user facility. To emphasize the importance of this milestone, the author shave made the design and organization of the report significantly different from previous IPNS Progress Reports. This report consists of two volumes. For Volume 1, authors were asked to prepare articles that highlighted recent scientific accomplishments at IPNS, from 1991 to present; to focus on and illustrate the scientific advances achieved through the unique capabilities of neutron studies performed by IPNS users; to report on specific activities or results from an instrument; or to focus on a body of work encompassing different neutron-scattering techniques. Articles were also included on the accelerator system, instrumentation, computing, target, and moderators. A list of published and ``in press` articles in journals, books, and conference proceedings, resulting from work done at IPNS since 1991, was compiled. This list is arranged alphabetically according to first author. Publication references in the articles are listed by last name of first author and year of publication. The IPNS experimental reports received since 1991 are compiled in Volume 2. Experimental reports referenced in the articles are listed by last name of first author, instrument designation, and experiment number.

  15. Measurement of orbital volume by computed tomography. Especially on the growth of orbit

    Energy Technology Data Exchange (ETDEWEB)

    Furuta, Minoru [Fukushima Medical Coll. (Japan)

    2000-10-01

    Using reconstructed X-ray computed tomography (CT) images of serial coronal sections, we measured the orbital volume and studied its changes with age. The subjects consisted of 109 patients (74 males, 35 females) who had undergone X-ray CT. After the reproducibility of orbital volume measurements and laterality in individuals were confirmed, the relation between the orbital volume and the age, sex, weight, and interlateral orbital rim distance were examined. The difference between two measurements in the same patients was 0.4% for measured volume, which showed the reproducibility of this measurement to be good. The laterality in individuals was 0.06 cm{sup 3}: this difference was very small and not significant. The orbital volume showed no unbalance between the right and left at any stage of growth. Both the height and the interlateral orbital rim distance had a strong correlation with the orbital volume. Referring to the relation between age and orbital volume, a strong correlation with an almost identical approximate equation was obtained for both sexes under 12 years of age. Presumably, the rapid growth of the orbit comes to an end by 15 years of age in males and 11 years in females. This means that more than 95% growth of adults has already been completed in the first half of the teens. The mean orbital volume in adult Japanese is 23.6{+-}2.0 (mean{+-}standard deviation) cm{sup 3} in males and 20.9{+-}1.3 cm{sup 3} in females. (author)

  16. Measurement of orbital volume by computed tomography. Especially on the growth of orbit

    International Nuclear Information System (INIS)

    Furuta, Minoru

    2000-01-01

    Using reconstructed X-ray computed tomography (CT) images of serial coronal sections, we measured the orbital volume and studied its changes with age. The subjects consisted of 109 patients (74 males, 35 females) who had undergone X-ray CT. After the reproducibility of orbital volume measurements and laterality in individuals were confirmed, the relation between the orbital volume and the age, sex, weight, and interlateral orbital rim distance were examined. The difference between two measurements in the same patients was 0.4% for measured volume, which showed the reproducibility of this measurement to be good. The laterality in individuals was 0.06 cm 3 : this difference was very small and not significant. The orbital volume showed no unbalance between the right and left at any stage of growth. Both the height and the interlateral orbital rim distance had a strong correlation with the orbital volume. Referring to the relation between age and orbital volume, a strong correlation with an almost identical approximate equation was obtained for both sexes under 12 years of age. Presumably, the rapid growth of the orbit comes to an end by 15 years of age in males and 11 years in females. This means that more than 95% growth of adults has already been completed in the first half of the teens. The mean orbital volume in adult Japanese is 23.6±2.0 (mean±standard deviation) cm 3 in males and 20.9±1.3 cm 3 in females. (author)

  17. Method of phase-Doppler anemometry free from the measurement-volume effect.

    Science.gov (United States)

    Qiu, H; Hsu, C T

    1999-05-01

    A novel method is developed to improve the accuracy of particle sizing in laser phase-Doppler anemometry (PDA). In this method the vector sum of refractive and reflective rays is taken into consideration in describing a dual-mechanism-scattering model caused by a nonuniformly illuminated PDA measurement volume. The constraint of the single-mechanism-scattering model in the conventional PDA is removed. As a result the error caused by the measurement-volume effect, which consists of a Gaussian-beam defect and a slit effect, can be eliminated. This new method can be easily implemented with minimal modification of the conventional PDA system. The results of simulation based on the generalized Lorenz-Mie theory show that the new method can provide a PDA system free from the measurement-volume effect.

  18. Advanced Neutron Source enrichment study. Volume 2: Appendices -- Final report, Revision 12/94

    International Nuclear Information System (INIS)

    Bari, R.A.; Ludewig, H.; Weeks, J.

    1994-01-01

    A study has been performed of the impact on performance of using low enriched uranium (20% 235 U) or medium enriched uranium (35% 235 U) as an alternative fuel for the Advanced Neutron Source, which is currently designed to use uranium enriched to 93% 235 U. Higher fuel densities and larger volume cores were evaluated at the lower enrichments in terms of impact on neutron flux, safety, safeguards, technical feasibility, and cost. The feasibility of fabricating uranium silicide fuel at increasing material density was specifically addressed by a panel of international experts on research reactor fuels. The most viable alternative designs for the reactor at lower enrichments were identified and discussed. Several sensitivity analyses were performed to gain an understanding of the performance of the reactor at parametric values of power, fuel density, core volume, and enrichment that were interpolations between the boundary values imposed on the study or extrapolations from known technology. Volume 2 of this report contains 26 appendices containing results, meeting minutes, and fuel panel presentations. There are 26 appendices in this volume

  19. Data format standard for sharing light source measurements

    Science.gov (United States)

    Gregory, G. Groot; Ashdown, Ian; Brandenburg, Willi; Chabaud, Dominique; Dross, Oliver; Gangadhara, Sanjay; Garcia, Kevin; Gauvin, Michael; Hansen, Dirk; Haraguchi, Kei; Hasna, Günther; Jiao, Jianzhong; Kelley, Ryan; Koshel, John; Muschaweck, Julius

    2013-09-01

    Optical design requires accurate characterization of light sources for computer aided design (CAD) software. Various methods have been used to model sources, from accurate physical models to measurement of light output. It has become common practice for designers to include measured source data for design simulations. Typically, a measured source will contain rays which sample the output distribution of the source. The ray data must then be exported to various formats suitable for import into optical analysis or design software. Source manufacturers are also making measurements of their products and supplying CAD models along with ray data sets for designers. The increasing availability of data has been beneficial to the design community but has caused a large expansion in storage needs for the source manufacturers since each software program uses a unique format to describe the source distribution. In 2012, the Illuminating Engineering Society (IES) formed a working group to understand the data requirements for ray data and recommend a standard file format. The working group included representatives from software companies supplying the analysis and design tools, source measurement companies providing metrology, source manufacturers creating the data and users from the design community. Within one year the working group proposed a file format which was recently approved by the IES for publication as TM-25. This paper will discuss the process used to define the proposed format, highlight some of the significant decisions leading to the format and list the data to be included in the first version of the standard.

  20. Measurement of the airway surface liquid volume with simple light refraction microscopy.

    Science.gov (United States)

    Harvey, Peter R; Tarran, Robert; Garoff, Stephen; Myerburg, Mike M

    2011-09-01

    In the cystic fibrosis (CF) lung, the airway surface liquid (ASL) volume is depleted, impairing mucus clearance from the lung and leading to chronic airway infection and obstruction. Several therapeutics have been developed that aim to restore normal airway surface hydration to the CF airway, yet preclinical evaluation of these agents is hindered by the paucity of methods available to directly measure the ASL. Therefore, we sought to develop a straightforward approach to measure the ASL volume that would serve as the basis for a standardized method to assess mucosal hydration using readily available resources. Primary human bronchial epithelial (HBE) cells cultured at an air-liquid interface develop a liquid meniscus at the edge of the culture. We hypothesized that the size of the fluid meniscus is determined by the ASL volume, and could be measured as an index of the epithelial surface hydration status. A simple method was developed to measure the volume of fluid present in meniscus by imaging the refraction of light at the ASL interface with the culture wall using low-magnification microscopy. Using this method, we found that primary CF HBE cells had a reduced ASL volume compared with non-CF HBE cells, and that known modulators of ASL volume caused the predicted responses. Thus, we have demonstrated that this method can detect physiologically relevant changes in the ASL volume, and propose that this novel approach may be used to rapidly assess the effects of airway hydration therapies in high-throughput screening assays.

  1. SPECT measurements of cerebral blood volume before and after acetazolamide in occlusive cerebrovascular diseases

    International Nuclear Information System (INIS)

    Inoue, Yusuke; Momose, Toshimitsu; Machida, Kikuo; Honda, Norinari; Nishikawa, Junichi; Sasaki, Yasuhito.

    1994-01-01

    Cerebral blood volume before and after acetazolamide was measured by SPECT to evaluate cerebral vasodilatory capacity in eight patients with cerebrovascular disease and five control subjects. Two SPECT measurements were performed serially, and acetazolamide was administered between them. The ratio of increase in hemispheric blood volume was calculated, and it was compared with the results of cerebral blood flow and cerebral blood volume measurements. A cerebral vasodilatory capacity map, the image after acetazolamide minus the baseline image, was also produced. Acetazolamide increased hemispheric blood volume in all subjects. The ratio of increase was lower in the involved hemispheres of the patients with unilateral carotid disease than in the uninvolved hemispheres of the patients and control subjects. The ratio of concordance with blood flow and blood volume measurements was approximated at 80%. Cerebral vasodilatory capacity mapping revealed three defects compatible with the clinical data. SPECT measurements of cerebral blood volume after acetazolamide can be performed following baseline SPECT with no additional radiotracer, and may be helpful to assess hemodynamic status. (author)

  2. Deep Downhole Seismic Testing at the Waste Treatment Plant Site, Hanford, WA. Volume V S-Wave Measurements in Borehole C4996 Seismic Records, Wave-Arrival Identifications and Interpreted S-Wave Velocity Profile.

    Energy Technology Data Exchange (ETDEWEB)

    Stokoe, Kenneth H.; Li, Song Cheng; Cox, Brady R.; Menq, Farn-Yuh

    2007-06-06

    Velocity measurements in shallow sediments from ground surface to approximately 370 to 400 feet bgs were collected by Redpath Geophysics using impulsive S- and P-wave seismic sources (Redpath 2007). Measurements below this depth within basalt and sedimentary interbeds were made by UTA between October and December 2006 using the T-Rex vibratory seismic source in each of the three boreholes. Results of these measurements including seismic records, wave-arrival identifications and interpreted velocity profiles are presented in the following six volumes: I. P-Wave Measurements in Borehole C4993 II. P-Wave Measurements in Borehole C4996 III. P-Wave Measurements in Borehole C4997 IV. S-Wave Measurements in Borehole C4993 V. S-Wave Measurements in Borehole C4996 VI. S-Wave Measurements in Borehole C4997 In this volume (V), all S-wave measurements are presented that were performed in Borehole C4996 at the WTP with T-Rex as the seismic source and the Lawrence Berkeley National Laboratory (LBNL) 3-D wireline geophone as the at-depth borehole receiver.

  3. Deep Downhole Seismic Testing at the Waste Treatment Plant Site, Hanford, WA. Volume VI S-Wave Measurements in Borehole C4997 Seismic Records, Wave-Arrival Identifications and Interpreted S-Wave Velocity Profile.

    Energy Technology Data Exchange (ETDEWEB)

    Stokoe, Kenneth H.; Li, Song Cheng; Cox, Brady R.; Menq, Farn-Yuh

    2007-06-06

    Velocity measurements in shallow sediments from ground surface to approximately 370 to 400 feet bgs were collected by Redpath Geophysics using impulsive S- and P-wave seismic sources (Redpath 2007). Measurements below this depth within basalt and sedimentary interbeds were made by UTA between October and December 2006 using the T-Rex vibratory seismic source in each of the three boreholes. Results of these measurements including seismic records, wave-arrival identifications and interpreted velocity profiles are presented in the following six volumes: I. P-Wave Measurements in Borehole C4993 II. P-Wave Measurements in Borehole C4996 III. P-Wave Measurements in Borehole C4997 IV. S-Wave Measurements in Borehole C4993 V. S-Wave Measurements in Borehole C4996 VI. S-Wave Measurements in Borehole C4997 In this volume (VI), all S-wave measurements are presented that were performed in Borehole C4997 at the WTP with T-Rex as the seismic source and the Lawrence Berkeley National Laboratory (LBNL) 3-D wireline geophone as the at-depth borehole receiver.

  4. Field Operations and Enforcement Manual for Air Pollution Control. Volume II: Control Technology and General Source Inspection.

    Science.gov (United States)

    Weisburd, Melvin I.

    The Field Operations and Enforcement Manual for Air Pollution Control, Volume II, explains in detail the following: technology of source control, modification of operations, particulate control equipment, sulfur dioxide removal systems for power plants, and control equipment for gases and vapors; inspection procedures for general sources, fuel…

  5. Macular volume and central foveal thickness measurements in ...

    African Journals Online (AJOL)

    Objective: To determine macular volume and central foveal thickness measurements in normal eyes of healthy. Nigerian adults using Stratus optical coherence tomography. Subjects and Methods: Consenting 100 adults Nigerians with normal eyes were recruited and examined using Carl. Zeiss Stratus Optical Coherence ...

  6. The evaluation of gallbladder contractibility for volume measurement by helical 3D-CT-cholangiography

    International Nuclear Information System (INIS)

    Hanaguri, Katsuro; Kimura, Hideaki; Kayashima, Yasuyo; Suemoto, Kouichiro; Makihata, Hiroshi; Maruhashi, Akira; Ohya, Toshihide; Ito, Katsuhide; Shen, Yun.

    1997-01-01

    As a new application of helical (spiral) scan, volume measurement has received a significant interest. Although it is important to evaluate gallbladder contractibility to decide on a treatment plan for a gallbladder lesion, qualitative analysis of gallbladder contractibility is very difficult owing to the fact that the volume of gallbladder can not be measured using usual DIC examination (plain X-P and tomography). In this study, the accuracy of volume measurement of helical CT was checked firstly by gallbladder phantom experiments. Then 128 cases of volume measurement of helical 3D CT Cholangiography (DIC-CT) were performed. Under the conditions of optimized scan technique (3 mm TH, 3 mm/s, 1 mm recon interval, Hispeed, GEMS), the difference of contractibility was obtained between clinical cases with and without thick wall. The experiment has shown that helical 3D CT volume measurement is very simple and highly accurate method which is useful for the evaluation of gallbladder contractibility. (author)

  7. Semiautomatic regional segmentation to measure orbital fat volumes in thyroid-associated ophthalmopathy. A validation study.

    Science.gov (United States)

    Comerci, M; Elefante, A; Strianese, D; Senese, R; Bonavolontà, P; Alfano, B; Bonavolontà, B; Brunetti, A

    2013-08-01

    This study was designed to validate a novel semi-automated segmentation method to measure regional intra-orbital fat tissue volume in Graves' ophthalmopathy. Twenty-four orbits from 12 patients with Graves' ophthalmopathy, 24 orbits from 12 controls, ten orbits from five MRI study simulations and two orbits from a digital model were used. Following manual region of interest definition of the orbital volumes performed by two operators with different levels of expertise, an automated procedure calculated intra-orbital fat tissue volumes (global and regional, with automated definition of four quadrants). In patients with Graves' disease, clinical activity score and degree of exophthalmos were measured and correlated with intra-orbital fat volumes. Operator performance was evaluated and statistical analysis of the measurements was performed. Accurate intra-orbital fat volume measurements were obtained with coefficients of variation below 5%. The mean operator difference in total fat volume measurements was 0.56%. Patients had significantly higher intra-orbital fat volumes than controls (p<0.001 using Student's t test). Fat volumes and clinical score were significantly correlated (p<0.001). The semi-automated method described here can provide accurate, reproducible intra-orbital fat measurements with low inter-operator variation and good correlation with clinical data.

  8. Open-source Software for Demand Forecasting of Clinical Laboratory Test Volumes Using Time-series Analysis.

    Science.gov (United States)

    Mohammed, Emad A; Naugler, Christopher

    2017-01-01

    Demand forecasting is the area of predictive analytics devoted to predicting future volumes of services or consumables. Fair understanding and estimation of how demand will vary facilitates the optimal utilization of resources. In a medical laboratory, accurate forecasting of future demand, that is, test volumes, can increase efficiency and facilitate long-term laboratory planning. Importantly, in an era of utilization management initiatives, accurately predicted volumes compared to the realized test volumes can form a precise way to evaluate utilization management initiatives. Laboratory test volumes are often highly amenable to forecasting by time-series models; however, the statistical software needed to do this is generally either expensive or highly technical. In this paper, we describe an open-source web-based software tool for time-series forecasting and explain how to use it as a demand forecasting tool in clinical laboratories to estimate test volumes. This tool has three different models, that is, Holt-Winters multiplicative, Holt-Winters additive, and simple linear regression. Moreover, these models are ranked and the best one is highlighted. This tool will allow anyone with historic test volume data to model future demand.

  9. Open-source software for demand forecasting of clinical laboratory test volumes using time-series analysis

    Directory of Open Access Journals (Sweden)

    Emad A Mohammed

    2017-01-01

    Full Text Available Background: Demand forecasting is the area of predictive analytics devoted to predicting future volumes of services or consumables. Fair understanding and estimation of how demand will vary facilitates the optimal utilization of resources. In a medical laboratory, accurate forecasting of future demand, that is, test volumes, can increase efficiency and facilitate long-term laboratory planning. Importantly, in an era of utilization management initiatives, accurately predicted volumes compared to the realized test volumes can form a precise way to evaluate utilization management initiatives. Laboratory test volumes are often highly amenable to forecasting by time-series models; however, the statistical software needed to do this is generally either expensive or highly technical. Method: In this paper, we describe an open-source web-based software tool for time-series forecasting and explain how to use it as a demand forecasting tool in clinical laboratories to estimate test volumes. Results: This tool has three different models, that is, Holt-Winters multiplicative, Holt-Winters additive, and simple linear regression. Moreover, these models are ranked and the best one is highlighted. Conclusion: This tool will allow anyone with historic test volume data to model future demand.

  10. Instrumentation for environmental monitoring. Volume 1. Radiation. Second Edition

    International Nuclear Information System (INIS)

    Budnitz, R.J.; Nero, A.V.; Murphy, D.J.; Graven, R.

    1983-01-01

    This volume describes ionizing radiation and the instruments used for measurement. Units, sources, and effects of radiation are introduced, basic detection methods discussed, and measurement of alpha, beta, gamma and x-radiation described. Sources of anthropogenic radiation are discussed in detail: nuclear power plants, spent-fuel processing, and uranium mining and milling

  11. Errors during MRT measurements of the left ventricular volume using a multi-slice technique

    International Nuclear Information System (INIS)

    Pitton, M.B.; Just, M.; Grebe, P.; Kreitner, K.F.; Erbel, R.; Thelen, M.

    1992-01-01

    A multi-slice technique for MRT measurements of the left ventricular volume is much faster than the use of single-slice methods and is therefore better tolerated, leaving time for additional measurements. The end-diastolic left ventricular volume can be reliably measured by this method (123.3±13.5 ml vs. 124.1±ml). The end-systolic volume is consistently overestimated by 23.7±18,3% compared with the reference value obtained by single slice measurements (47.9±8.9 ml vs 39.1±7.9 ml). Correspondingly, stroke volume and ejection fraction is underestimated on average by 10.6±9.7% and 10.6±7.6% respectively). (orig.) [de

  12. Environmental effects of energy production and utilization in the U.S. Volume I. Sources, trends, and costs of control

    International Nuclear Information System (INIS)

    Newkirk, H.W.

    1976-01-01

    Volume I deals with sources (what the emissions are and where they come from), trends (quantities of emissions and their dispersion with time), and costs of control (what it takes in time, energy, and money to meet minimum standards). Volume II concerns itself with the public health effects of energy production and utilization. Volume III summarizes the various techniques for controlling emissions, technological as well as economic, social, and political. Each volume is divided into sections dealing with the atmosphere, water, land, and social activities--each division indicating a particular sphere of man's environment affected by energy production and use. The sources of information that were used in this study included textbooks, journal articles, technical reports, memoranda, letters, and personal communications. These are cited in the text at the end of each subsection and on the applicable tables and figures

  13. The Use of Helmholtz Resonance for Measuring the Volume of Liquids and Solids

    Directory of Open Access Journals (Sweden)

    Clive E. Davies

    2010-11-01

    Full Text Available An experimental investigation was undertaken to ascertain the potential of using Helmholtz resonance for volume determination and the factors that may influence accuracy. The uses for a rapid non-interference volume measurement system range from agricultural produce and mineral sampling through to liquid fill measurements. By weighing the sample the density can also measured indirectly.

  14. Significance of left ventricular volume measurement after heart transplantation using radionuclide techniques

    International Nuclear Information System (INIS)

    Novitzky, D.; Cooper, D.; Boniaszczuk, J.

    1985-01-01

    Multigated equilibrium blood pool scanning using Technetium 99m labeled red blood cells was used to measure left ventricular volumes in three heterotopic and one orthotopic heart transplant recipient(s). Simultaneously, an endomyocardial biopsy was performed and the degree of acute rejection was assessed by a histological scoring system. The scores were correlated to changes in ejection fraction and heart rate. Technetium 99m scanning data were pooled according to the endomyocardial biopsy score: no rejection; mild rejection; moderate rejection, and severe rejection. In each group, the median of the left ventricular volume parameters was calculated and correlated with the endomyocardial biopsy score, using a non-parametric one-way analysis of variance. A decrease in stroke volume correlated best with the endomyocardial biopsy score during acute rejection. A decrease in end-diastolic left ventricular volumes did not correlate as well. Changes in the end-systolic left ventricular volumes were not statistically significant, but using a simple correlation between end-systolic left ventricular volumes and endomyocardial biopsy the correlation reached significance. Changes in left ventricular volumes measured by Technetium 99m scanning may be useful to confirm the presence or absence of acute rejection in patients with heart grafts

  15. Measurement of transplanted pancreatic volume using computed tomography: reliability by intra- and inter-observer variability

    International Nuclear Information System (INIS)

    Lundqvist, Eva; Segelsjoe, Monica; Magnusson, Anders; Andersson, Anna; Biglarnia, Ali-Reza

    2012-01-01

    Background Unlike other solid organ transplants, pancreas allografts can undergo a substantial decrease in baseline volume after transplantation. This phenomenon has not been well characterized, as there are insufficient data on reliable and reproducible volume assessments. We hypothesized that characterization of pancreatic volume by means of computed tomography (CT) could be a useful method for clinical follow-up in pancreas transplant patients. Purpose To evaluate the feasibility and reliability of pancreatic volume assessment using CT scan in transplanted patients. Material and Methods CT examinations were performed on 21 consecutive patients undergoing pancreas transplantation. Volume measurements were carried out by two observers tracing the pancreatic contours in all slices. The observers performed the measurements twice for each patient. Differences in volume measurement were used to evaluate intra- and inter-observer variability. Results The intra-observer variability for the pancreatic volume measurements of Observers 1 and 2 was found to be in almost perfect agreement, with an intraclass correlation coefficient (ICC) of 0.90 (0.77-0.96) and 0.99 (0.98-1.0), respectively. Regarding inter-observer validity, the ICCs for the first and second measurements were 0.90 (range, 0.77-0.96) and 0.95 (range, 0.85-0.98), respectively. Conclusion CT volumetry is a reliable and reproducible method for measurement of transplanted pancreatic volume

  16. Measurement of transplanted pancreatic volume using computed tomography: reliability by intra- and inter-observer variability

    Energy Technology Data Exchange (ETDEWEB)

    Lundqvist, Eva; Segelsjoe, Monica; Magnusson, Anders [Uppsala Univ., Dept. of Radiology, Oncology and Radiation Science, Section of Radiology, Uppsala (Sweden)], E-mail: eva.lundqvist.8954@student.uu.se; Andersson, Anna; Biglarnia, Ali-Reza [Dept. of Surgical Sciences, Section of Transplantation Surgery, Uppsala Univ. Hospital, Uppsala (Sweden)

    2012-11-15

    Background Unlike other solid organ transplants, pancreas allografts can undergo a substantial decrease in baseline volume after transplantation. This phenomenon has not been well characterized, as there are insufficient data on reliable and reproducible volume assessments. We hypothesized that characterization of pancreatic volume by means of computed tomography (CT) could be a useful method for clinical follow-up in pancreas transplant patients. Purpose To evaluate the feasibility and reliability of pancreatic volume assessment using CT scan in transplanted patients. Material and Methods CT examinations were performed on 21 consecutive patients undergoing pancreas transplantation. Volume measurements were carried out by two observers tracing the pancreatic contours in all slices. The observers performed the measurements twice for each patient. Differences in volume measurement were used to evaluate intra- and inter-observer variability. Results The intra-observer variability for the pancreatic volume measurements of Observers 1 and 2 was found to be in almost perfect agreement, with an intraclass correlation coefficient (ICC) of 0.90 (0.77-0.96) and 0.99 (0.98-1.0), respectively. Regarding inter-observer validity, the ICCs for the first and second measurements were 0.90 (range, 0.77-0.96) and 0.95 (range, 0.85-0.98), respectively. Conclusion CT volumetry is a reliable and reproducible method for measurement of transplanted pancreatic volume.

  17. 21 CFR 864.5950 - Blood volume measuring device.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Blood volume measuring device. 864.5950 Section 864.5950 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Automated and Semi-Automated Hematology Devices...

  18. A measurement-based X-ray source model characterization for CT dosimetry computations.

    Science.gov (United States)

    Sommerville, Mitchell; Poirier, Yannick; Tambasco, Mauro

    2015-11-08

    within the experimental uncertainties associated with measurement reproducibility and chamber volume effects for the PMMA phantom. The agreement between calculation and measurement was within experimental uncertainty for 19 out of 20 simulation conditions at five points of interest in the anthropomorphic thorax phantom for the four beam energies modeled. The source model and characterization technique based on HVL measurements and nominal kVp can be used to accurately compute CT dose. This accuracy provides experimental validation of kVDoseCalc for computing CT dose.

  19. Results of Long-term Measurement of 222Rn Volume Activity in Soil Air

    International Nuclear Information System (INIS)

    Holy, K.; Matos, M.; Boem, R.; Stanys, T.; Hola, O.; Polaskova, A.

    1999-01-01

    Radon in the soil air was continuously monitored for four years. The measured volume activities differ one from another even three times. On the basis of the measured data the annual and average daily courses of the 222 Rn volume activity were studied for individual months. In annual courses the winter and also summer maxima of the 222 Rn volume activity were found out. The study of the average daily courses revealed that the oscillation of the 222 Rn volume activity about its average value during a day is only a few percent. For dry summer months a linear relation was found out between the changes of the 222 Rn volume activity and the changes of the atmospheric pressure in their average daily courses (Authors)

  20. Ultrasound measurements of testicular volume: Comparing the three ...

    African Journals Online (AJOL)

    T.U. Mbaeri

    The ultrasound measurements of the testicular volume were calculated using the following three formulas: (a) length ... ticular growth, development and function. Studies in ... of the components of a minimum full evaluation of male infertility is palpation of ... opted for orchidectomy after counseling in our center. Subjects and ...

  1. Rectal compliance as a routine measurement: extreme volumes have direct clinical impact and normal volumes exclude rectum as a problem.

    Science.gov (United States)

    Felt-Bersma, R J; Sloots, C E; Poen, A C; Cuesta, M A; Meuwissen, S G

    2000-12-01

    The clinical impact of rectal compliance and sensitivity measurement is not clear. The aim of this study was to measure the rectal compliance in different patient groups compared with controls and to establish the clinical effect of rectal compliance. Anorectal function tests were performed in 974 consecutive patients (284 men). Normal values were obtained from 24 controls. Rectal compliance measurement was performed by filling a latex rectal balloon with water at a rate of 60 ml per minute. Volume and intraballoon pressure were measured. Volume and pressure at three sensitivity thresholds were recorded for analysis: first sensation, urge, and maximal toleration. At maximal toleration, the rectal compliance (volume/pressure) was calculated. Proctoscopy, anal manometry, anal mucosal sensitivity, and anal endosonography were also performed as part of our anorectal function tests. No effect of age or gender was observed in either controls or patients. Patients with fecal incontinence had a higher volume at first sensation and a higher pressure at maximal toleration (P = 0.03), the presence of a sphincter defect or low or normal anal pressures made no difference. Patients with constipation had a larger volume at first sensation and urge (P 500 ml had complaints of constipation. No correlation between rectal and anal mucosal sensitivity was found. Rectal compliance measurement with a latex balloon is easily feasible. In this series of 974 patients, some patient groups showed an abnormal rectal visceral sensitivity and compliance, but there was an overlap with controls. Rectal compliance measurement gave a good clinical impression about the contribution of the rectum to the anorectal problem. Patients with proctitis and pouchitis had the smallest rectal compliance. A maximal toleration volume 500 ml was only seen in constipated patients, and therapy should be given to prevent further damage to the pelvic floor. Values close to or within the normal range rule out the

  2. Reheating-volume measure for random-walk inflation

    International Nuclear Information System (INIS)

    Winitzki, Sergei

    2008-01-01

    The recently proposed 'reheating-volume' (RV) measure promises to solve the long-standing problem of extracting probabilistic predictions from cosmological multiverse scenarios involving eternal inflation. I give a detailed description of the new measure and its applications to generic models of eternal inflation of random-walk type. For those models I derive a general formula for RV-regulated probability distributions that is suitable for numerical computations. I show that the results of the RV cutoff in random-walk type models are always gauge invariant and independent of the initial conditions at the beginning of inflation. In a toy model where equal-time cutoffs lead to the 'youngness paradox', the RV cutoff yields unbiased results that are distinct from previously proposed measures.

  3. Measurement of right ventricular volumes using 131I-MAA

    International Nuclear Information System (INIS)

    Sekimoto, T.; Grover, R.F.

    1975-01-01

    A method is presented for determining the right ventricular residual ratio, that is, the ratio of the end-systolic volume to the end-diastolic volume during each cardiac cycle. 131 I-MAA was injected as a bolus into the right ventricle, and the ratio of isotope remaining in the chamber during the succeeding cardiac cycles was determined with a collimated scintillation counter placed over the right ventricle. Since the counter detected the radioactivity from the entire right ventricular cavity, potential errors from incomplete mixing were minimized. The washout curve from the ventricle was distorted somewhat by the accumulation of isotope in intervening lung tissue. This distortion was eliminated by subtracting the build-up curve of radioactivity in the lung recorded simultaneously with a second scintillation counter positioned over the lateral chest wall. In 14 dogs anesthetized with chloralose, the right ventricular residual ratio was relatively constant at 40.4 +- 3.1 per cent. Duplicate measurements differed by less than 3 percent indicating the good reproducibility of the method. Right ventricular stroke volume was determined from cardiac output (dye dilution) and heart rate. With this and the simultaneously determined residual ratio ( 131 I-MAA), end-diastolic volume could be calculated. Stroke volume and stroke work were highly correlated with end-diastolic volume, in keeping with the Frank-Starling mechanism. (U.S.)

  4. Environmental Toxicology: A Guide to Information Sources. Volume 7 in the "Man and the Environment Information Guide" Series.

    Science.gov (United States)

    Rudd, Robert L.

    This annotated bibliography on environmental toxicology brings together a diverse set of information sources from the physical, social, and natural sciences. These sources include periodical literature, government documents, scientific journals, and teaching materials. The volume is divided into sixteen sections organized into four parts: (1)…

  5. Environmental effects of energy production and utilization in the U. S. Volume I. Sources, trends, and costs of control

    Energy Technology Data Exchange (ETDEWEB)

    Newkirk, H.W. (comp.)

    1976-05-01

    Volume I deals with sources (what the emissions are and where they come from), trends (quantities of emissions and their dispersion with time), and costs of control (what it takes in time, energy, and money to meet minimum standards). Volume II concerns itself with the public health effects of energy production and utilization. Volume III summarizes the various techniques for controlling emissions, technological as well as economic, social, and political. (For abstracts of Vols. II and III, see ERDA Energy Research Abstracts, Vol. 2, Absts. 5764 and 5670, respectively) Each volume is divided into sections dealing with the atmosphere, water, land, and social activities--each division indicating a particular sphere of man's environment affected by energy production and use. The sources of information that were used in this study included textbooks, journal articles, technical reports, memoranda, letters, and personal communications. These are cited in the text at the end of each subsection and on the applicable tables and figures.

  6. Estimating retained gas volumes in the Hanford tanks using waste level measurements

    International Nuclear Information System (INIS)

    Whitney, P.D.; Chen, G.; Gauglitz, P.A.; Meyer, P.A.; Miller, N.E.

    1997-09-01

    The Hanford site is home to 177 large, underground nuclear waste storage tanks. Safety and environmental concerns surround these tanks and their contents. One such concern is the propensity for the waste in these tanks to generate and trap flammable gases. This report focuses on understanding and improving the quality of retained gas volume estimates derived from tank waste level measurements. While direct measurements of gas volume are available for a small number of the Hanford tanks, the increasingly wide availability of tank waste level measurements provides an opportunity for less expensive (than direct gas volume measurement) assessment of gas hazard for the Hanford tanks. Retained gas in the tank waste is inferred from level measurements -- either long-term increase in the tank waste level, or fluctuations in tank waste level with atmospheric pressure changes. This report concentrates on the latter phenomena. As atmospheric pressure increases, the pressure on the gas in the tank waste increases, resulting in a level decrease (as long as the tank waste is open-quotes softclose quotes enough). Tanks with waste levels exhibiting fluctuations inversely correlated with atmospheric pressure fluctuations were catalogued in an earlier study. Additionally, models incorporating ideal-gas law behavior and waste material properties have been proposed. These models explicitly relate the retained gas volume in the tank with the magnitude of the waste level fluctuations, dL/dP. This report describes how these models compare with the tank waste level measurements

  7. Model-based segmentation in orbital volume measurement with cone beam computed tomography and evaluation against current concepts.

    Science.gov (United States)

    Wagner, Maximilian E H; Gellrich, Nils-Claudius; Friese, Karl-Ingo; Becker, Matthias; Wolter, Franz-Erich; Lichtenstein, Juergen T; Stoetzer, Marcus; Rana, Majeed; Essig, Harald

    2016-01-01

    Objective determination of the orbital volume is important in the diagnostic process and in evaluating the efficacy of medical and/or surgical treatment of orbital diseases. Tools designed to measure orbital volume with computed tomography (CT) often cannot be used with cone beam CT (CBCT) because of inferior tissue representation, although CBCT has the benefit of greater availability and lower patient radiation exposure. Therefore, a model-based segmentation technique is presented as a new method for measuring orbital volume and compared to alternative techniques. Both eyes from thirty subjects with no known orbital pathology who had undergone CBCT as a part of routine care were evaluated (n = 60 eyes). Orbital volume was measured with manual, atlas-based, and model-based segmentation methods. Volume measurements, volume determination time, and usability were compared between the three methods. Differences in means were tested for statistical significance using two-tailed Student's t tests. Neither atlas-based (26.63 ± 3.15 mm(3)) nor model-based (26.87 ± 2.99 mm(3)) measurements were significantly different from manual volume measurements (26.65 ± 4.0 mm(3)). However, the time required to determine orbital volume was significantly longer for manual measurements (10.24 ± 1.21 min) than for atlas-based (6.96 ± 2.62 min, p < 0.001) or model-based (5.73 ± 1.12 min, p < 0.001) measurements. All three orbital volume measurement methods examined can accurately measure orbital volume, although atlas-based and model-based methods seem to be more user-friendly and less time-consuming. The new model-based technique achieves fully automated segmentation results, whereas all atlas-based segmentations at least required manipulations to the anterior closing. Additionally, model-based segmentation can provide reliable orbital volume measurements when CT image quality is poor.

  8. Color structured light system of chest wall motion measurement for respiratory volume evaluation

    Science.gov (United States)

    Chen, Huijun; Cheng, Yuan; Liu, Dongdong; Zhang, Xiaodong; Zhang, Jue; Que, Chengli; Wang, Guangfa; Fang, Jing

    2010-03-01

    We present a structured light system to dynamically measure human chest wall motion for respiratory volume estimation. Based on a projection of an encoded color pattern and a few active markers attached to the trunk, respiratory volumes are obtained by evaluating the 3-D topographic changes of the chest wall in an anatomically consistent measuring region during respiration. Three measuring setups are established: a single-sided illuminating-recording setup for standing posture, an inclined single-sided setup for supine posture, and a double-sided setup for standing posture. Results are compared with the pneumotachography and show good agreement in volume estimations [correlation coefficient: R>0.99 (Pvolume during the isovolume maneuver (standard deviationpulmonary functional differences between the diseased and the contralateral sides of the thorax, and subsequent improvement of this imbalance after drainage. These results demonstrate the proposed optical method is capable of not only whole respiratory volume evaluation with high accuracy, but also regional pulmonary function assessment in different chest wall behaviors, with the advantage of whole-field measurement.

  9. Accuracy and reproducibility of simple cross-sectional linear and area measurements of brain structures and their comparison with volume measurements

    International Nuclear Information System (INIS)

    Whalley, H.C.; Wardlaw, J.M.

    2001-01-01

    Volumetric measurement of brain structure on brain images is regarded as a gold standard, yet is very time consuming. We wondered whether simple linear and area measurements might be as accurate and reproducible. Two observers independently measured the cross-sectional area of the corpus callosum, lentiform and caudate nuclei, thalamus, amygdalas, hippocampi, lateral and third ventricles, and the width of the sylvian and frontal interhemispheric fissures and brain stem on brain MRI of 55 patients using a program written in-house; one observer also measured the volumes of the basal ganglia, amygdalo-hippocampal complex and ventricular system using Analyze, and performed qualitative assessment of four regions (lateral and third ventricles, cortex, and medial temporal lobe) using the Lieberman score. All measures were performed blinded to all other information. Test objects of known size were also imaged with MRI and measured by the two observers using the in-house program. The true sizes of the test objects were measured using engineering calipers by two observers blind to the MRI results. Differences between the two observers using the same measurement method, and one observer using different methods, were calculated. The simple linear and cross-sectional area measurements were rapid (20 min versus 5 h for volumetric); were highly accurate for test-object measurement versus true size; had excellent intraobserver reliability; and, for most brain structures, the simple measures correlated highly significantly with volumetric measures. The simple measures were in general highly reproducible, the difference (as a percentage of the area or width of a region) between the two raters being around 10 %, range 0.1 %- 14.1 %, (similar to inter-rater variability in previous studies of volume measurements). The simple linear and area measures are reproducible and correlate well with the measured volumes, and there is a considerable time saving with the former. In circumstances

  10. Radiologic measurement of extraocular muscle volumes in patients with Graves' orbitopathy: a review and guideline

    NARCIS (Netherlands)

    Bijlsma, Ward R.; Mourits, Maarten Ph

    2006-01-01

    OBJECTIVE: To evaluate and compare techniques for extraocular muscle (EOM) volume measurement and to provide guidelines for future measurements. DESIGN: Systematic review. RESULTS: Existing techniques used to measure extraocular muscle volumes on radiologic scans can be divided into manual

  11. Sonographic measurement of thyroid gland volume: A comparison of 2D and 3D ultrasound

    Energy Technology Data Exchange (ETDEWEB)

    Ying, Michael [Department of Optometry and Radiography, Hong Kong Polytechnic University, Hung Hom, Kowloon, Hong Kong (China)]. E-mail: ormying@polyu.edu.hk; Sin Manhong [Department of Optometry and Radiography, Hong Kong Polytechnic University, Hung Hom, Kowloon, Hong Kong (China); Pang, Shuk-fan [Department of Optometry and Radiography, Hong Kong Polytechnic University, Hung Hom, Kowloon, Hong Kong (China)

    2005-11-01

    Aims: This study was undertaken to investigate the inter-observer reproducibility of 2D and 3D ultrasound in the measurement of thyroid gland volume. The symmetry of thyroid lobes in healthy subjects was also investigated. Materials and methods: The volume of the left and right lobes of the thyroid gland was measured in 20 healthy subjects (10 men and 10 women) using 2D and 3D ultrasound. On 2D ultrasound, the thyroid lobe volume was calculated by ellipsoid equation (volume = {pi}/6 x craniocaudal x mediolateral x anteroposterior dimensions), whereas 3D ultrasound volumetric measurements were performed with a 3D add-on system. In each subject, the thyroid gland was scanned by two operators to investigate inter-observer variability. Results: There was a moderate agreement between 2D and 3D ultrasound in the measurement of thyroid volume (r = 0.77). 3D ultrasound (90%) had a higher inter-observer reproducibility than 2D ultrasound (85%) in the measurements. About 74% of healthy subjects had the right thyroid lobe larger than the left lobe. Conclusion: 3D ultrasound is useful in the measurement of thyroid volume with a higher reproducibility than 2D ultrasound. Asymmetry of thyroid lobes was noted in healthy subjects.

  12. Sonographic measurement of thyroid gland volume: A comparison of 2D and 3D ultrasound

    International Nuclear Information System (INIS)

    Ying, Michael; Sin Manhong; Pang, Shuk-fan

    2005-01-01

    Aims: This study was undertaken to investigate the inter-observer reproducibility of 2D and 3D ultrasound in the measurement of thyroid gland volume. The symmetry of thyroid lobes in healthy subjects was also investigated. Materials and methods: The volume of the left and right lobes of the thyroid gland was measured in 20 healthy subjects (10 men and 10 women) using 2D and 3D ultrasound. On 2D ultrasound, the thyroid lobe volume was calculated by ellipsoid equation (volume = π/6 x craniocaudal x mediolateral x anteroposterior dimensions), whereas 3D ultrasound volumetric measurements were performed with a 3D add-on system. In each subject, the thyroid gland was scanned by two operators to investigate inter-observer variability. Results: There was a moderate agreement between 2D and 3D ultrasound in the measurement of thyroid volume (r = 0.77). 3D ultrasound (90%) had a higher inter-observer reproducibility than 2D ultrasound (85%) in the measurements. About 74% of healthy subjects had the right thyroid lobe larger than the left lobe. Conclusion: 3D ultrasound is useful in the measurement of thyroid volume with a higher reproducibility than 2D ultrasound. Asymmetry of thyroid lobes was noted in healthy subjects

  13. Adaptive B-spline volume representation of measured BRDF data for photorealistic rendering

    Directory of Open Access Journals (Sweden)

    Hyungjun Park

    2015-01-01

    Full Text Available Measured bidirectional reflectance distribution function (BRDF data have been used to represent complex interaction between lights and surface materials for photorealistic rendering. However, their massive size makes it hard to adopt them in practical rendering applications. In this paper, we propose an adaptive method for B-spline volume representation of measured BRDF data. It basically performs approximate B-spline volume lofting, which decomposes the problem into three sub-problems of multiple B-spline curve fitting along u-, v-, and w-parametric directions. Especially, it makes the efficient use of knots in the multiple B-spline curve fitting and thereby accomplishes adaptive knot placement along each parametric direction of a resulting B-spline volume. The proposed method is quite useful to realize efficient data reduction while smoothing out the noises and keeping the overall features of BRDF data well. By applying the B-spline volume models of real materials for rendering, we show that the B-spline volume models are effective in preserving the features of material appearance and are suitable for representing BRDF data.

  14. Accuracy of Standing-Tree Volume Estimates Based on McClure Mirror Caliper Measurements

    Science.gov (United States)

    Noel D. Cost

    1971-01-01

    The accuracy of standing-tree volume estimates, calculated from diameter measurements taken by a mirror caliper and with sectional aluminum poles for height control, was compared with volume estimates calculated from felled-tree measurements. Twenty-five trees which varied in species, size, and form were used in the test. The results showed that two estimates of total...

  15. Tank waste source term inventory validation. Volume 1. Letter report

    International Nuclear Information System (INIS)

    Brevick, C.H.; Gaddis, L.A.; Johnson, E.D.

    1995-01-01

    The sample data for selection of 11 radionuclides and 24 chemical analytes were extracted from six separate sample data sets, were arranged in a tabular format and were plotted on scatter plots for all of the 149 single-shell tanks, the 24 double-shell tanks and the four aging waste tanks. The solid and liquid sample data was placed in separate tables and plots. The sample data and plots were compiled from the following data sets: characterization raw sample data, recent core samples, D. Braun data base, Wastren (Van Vleet) data base, TRAC and HTCE inventories. This document is Volume I of the Letter Report entitled Tank Waste Source Term Inventory Validation

  16. Advanced energy sources and conversion techniques. Proceedings of a seminar. Volume 1. [35 papers

    Energy Technology Data Exchange (ETDEWEB)

    None

    1958-11-01

    The Seminar was organized as a series of tutorial presentations and round table discussions on a technical level to implement the following: (a) to identify and explore present and projected needs for energy sources and conversion techniques for military applications; (b) to exchange information on current and planned efforts in these fields; (c) to examine the effect of anticipated scientific and technological advances on these efforts; and (d) to present suggested programs aimed at satisfying the military needs for energy sources and conversion techniques. Volume I contains all of the unclassified papers presented at the Seminar. (W.D.M.)

  17. Drop size distribution measured by imaging: determination of the measurement volume by the calibration of the point spread function

    International Nuclear Information System (INIS)

    Fdida, Nicolas; Blaisot, Jean-Bernard

    2010-01-01

    Measurement of drop size distributions in a spray depends on the definition of the control volume for drop counting. For image-based techniques, this implies the definition of a depth-of-field (DOF) criterion. A sizing procedure based on an imaging model and associated with a calibration procedure is presented. Relations between image parameters and object properties are used to provide a measure of the size of the droplets, whatever the distance from the in-focus plane. A DOF criterion independent of the size of the drops and based on the determination of the width of the point spread function (PSF) is proposed. It allows to extend the measurement volume to defocused droplets and, due to the calibration of the PSF, to clearly define the depth of the measurement volume. Calibrated opaque discs, calibrated pinholes and an optical edge are used for this calibration. A comparison of the technique with a phase Doppler particle analyser and a laser diffraction granulometer is performed on an application to an industrial spray. Good agreement is found between the techniques when particular care is given to the sampling of droplets. The determination of the measurement volume is used to determine the drop concentration in the spray and the maximum drop concentration that imaging can support

  18. Procedure for measurement of anisotropy factor for neutron sources

    International Nuclear Information System (INIS)

    Creazolla, Prycylla Gomes

    2017-01-01

    Radioisotope neutron sources allow the production of reference fields for calibration of neutron detectors for radiation protection and analysis purposes. When the emission rate of these sources is isotropic, no correction is necessary. However, variations in source encapsulation and in the radioactive material concentration produce differences in its neutron emission rate, relative to the source axis, this effect is called anisotropy. In this study, is describe a procedure for measuring the anisotropy factor of neutron sources performed in the Laboratório de Metrologia de Neutrons (LN) using a Precision Long Counter (PLC) detector. A measurement procedure that takes into account the anisotropy factor of neutron sources contributes to solve some issues, particularly with respect to the high uncertainties associated with neutron dosimetry. Thus, a bibliographical review was carried out based on international standards and technical regulations specific to the area of neutron fields, and were later reproduced in practice by means of the procedure for measuring the anisotropy factor in neutron sources of the LN. The anisotropy factor is determined as a function of the angle of 90° in relation to the cylindrical axis of the source. This angle is more important due to its high use in measurements and also of its higher neutron emission rate if compared with other angles. (author)

  19. Accuracy of cancellous bone volume fraction measured by micro-CT scanning

    DEFF Research Database (Denmark)

    Ding, Ming; Odgaard, A; Hvid, I

    1999-01-01

    Volume fraction, the single most important parameter in describing trabecular microstructure, can easily be calculated from three-dimensional reconstructions of micro-CT images. This study sought to quantify the accuracy of this measurement. One hundred and sixty human cancellous bone specimens...... which covered a large range of volume fraction (9.8-39.8%) were produced. The specimens were micro-CT scanned, and the volume fraction based on Archimedes' principle was determined as a reference. After scanning, all micro-CT data were segmented using individual thresholds determined by the scanner...

  20. Blood volume measurement with indocyanine green pulse spectrophotometry: dose and site of dye administration

    NARCIS (Netherlands)

    Germans, Menno R.; de Witt Hamer, Philip C.; van Boven, Leonard J.; Zwinderman, Koos A. H.; Bouma, Gerrit J.

    2010-01-01

    (1) To determine the optimal administration site and dose of indocyanine green (ICG) for blood volume measurement using pulse spectrophotometry, (2) to assess the variation in repeated blood volume measurements for patients after subarachnoid hemorrhage and (3) to evaluate the safety and efficacy of

  1. Using gas blow methods to realize accurate volume measurement of radioactivity liquid

    International Nuclear Information System (INIS)

    Zhang Caiyun

    2010-01-01

    For liquid which has radioactivity, Realized the accurate volume measurement uncertainty less than 0.2% (k=2) by means of gas blow methods presented in the 'American National Standard-Nuclear Material Control-Volume Calibration Methods(ANSI N15.19-1989)' and the 'ISO Committee Drafts (ISO/TC/85/SC 5N 282 )' and Explored a set methods of Data Processing. In the article, the major problems is to solve data acquisition and function foundation and measurement uncertainty estimate. (authors)

  2. Subject positioning in the BOD POD® only marginally affects measurement of body volume and estimation of percent body fat in young adult men.

    Directory of Open Access Journals (Sweden)

    Maarten W Peeters

    Full Text Available INTRODUCTION: The aim of the study was to evaluate whether subject positioning would affect the measurement of raw body volume, thoracic gas volume, corrected body volume and the resulting percent body fat as assessed by air displacement plethysmography (ADP. METHODS: Twenty-five young adult men (20.7±1.1 y, BMI = 22.5±1.4 kg/m(2 were measured using the BOD POD® system using a measured thoracic gas volume sitting in a 'forward bent' position and sitting up in a straight position in random order. RESULTS: Raw body volume was 58±124 ml (p<0.05 higher in the 'straight' position compared to the 'bent' position. The mean difference in measured thoracic gas volume (bent-straight = -71±211 ml was not statistically significant. Corrected body volume and percent body fat in the bent position consequently were on average 86±122 ml (p<0.05 and 0.5±0.7% (p<0.05 lower than in the straight position respectively. CONCLUSION: Although the differences reached statistical significance, absolute differences are rather small. Subject positioning should be viewed as a factor that may contribute to between-test variability and hence contribute to (inprecision in detecting small individual changes in body composition, rather than a potential source of systematic bias. It therefore may be advisable to pay attention to standardizing subject positioning when tracking small changes in PF are of interest. The cause of the differences is shown not to be related to changes in the volume of isothermal air in the lungs. It is hypothesized and calculated that the observed direction and magnitude of these differences may arise from the surface area artifact which does not take into account that a subject in the bent position exposes more skin to the air in the device therefore potentially creating a larger underestimation of the actual body volume due to the isothermal effect of air close to the skin.

  3. Non-Invasive Electromagnetic Skin Patch Sensor to Measure Intracranial Fluid–Volume Shifts

    Directory of Open Access Journals (Sweden)

    Jacob Griffith

    2018-03-01

    Full Text Available Elevated intracranial fluid volume can drive intracranial pressure increases, which can potentially result in numerous neurological complications or death. This study’s focus was to develop a passive skin patch sensor for the head that would non-invasively measure cranial fluid volume shifts. The sensor consists of a single baseline component configured into a rectangular planar spiral with a self-resonant frequency response when impinged upon by external radio frequency sweeps. Fluid volume changes (10 mL increments were detected through cranial bone using the sensor on a dry human skull model. Preliminary human tests utilized two sensors to determine feasibility of detecting fluid volume shifts in the complex environment of the human body. The correlation between fluid volume changes and shifts in the first resonance frequency using the dry human skull was classified as a second order polynomial with R2 = 0.97. During preliminary and secondary human tests, a ≈24 MHz and an average of ≈45.07 MHz shifts in the principal resonant frequency were measured respectively, corresponding to the induced cephalad bio-fluid shifts. This electromagnetic resonant sensor may provide a non-invasive method to monitor shifts in fluid volume and assist with medical scenarios including stroke, cerebral hemorrhage, concussion, or monitoring intracranial pressure.

  4. Measurement of liver and spleen volume by computed tomography using point counting technique

    International Nuclear Information System (INIS)

    Matsuda, Yoshiro; Sato, Hiroyuki; Nei, Jinichi; Takada, Akira

    1982-01-01

    We devised a new method for measurement of liver and spleen volume by computed tomography using point counting technique. This method is very simple and applicable to any kind of CT scanner. The volumes of the livers and spleens estimated by this method were significantly correlated with the weights of the corresponding organs measured on autopsy or surgical operation, indicating clinical usefulness of this method. Hepatic and splenic volumes were estimated by this method in 43 patients with chronic liver disease and 9 subjects with non-hepatobiliary disease. The mean hepatic volume in non-alcoholic liver cirrhosis was significantly smaller than those in non-hepatobiliary disease and other chronic liver diseases. The mean hepatic volume in alcoholic cirrhosis and alcoholic fibrosis tended to be slightly larger than that in non-hepatobiliary disease. The mean splenic volume in liver cirrhosis was significantly larger than those in non-hepatobiliary disease and other chronic liver diseases. However, there was no significant difference of the mean splenic volume between alcoholic and non-alcoholic cirrhosis. Significantly positive correlation between hepatic and splenic volumes was found in alcoholic cirrhosis, but not in non-alcoholic cirrhosis. These results indicate that estimation of hepatic and splenic volumes by this method is useful for the analysis of the pathophysiological condition of chronic liver diseases. (author)

  5. Final report on COOMET.RI(II)-S2.Eu-152 (319/RU/04): Comparison measurements of radionuclide volume sources (Eu-152)

    International Nuclear Information System (INIS)

    Korostin, S.; Hernandez, T.; Oropesa, P.; Arnold, D.; Evseev, V.; Ivanukovich, A.; Milevskiy, V.; Svec, A.; Lapenas, A.; Andonova, V.; Steiner, V.

    2010-01-01

    Measurements of the Eu-152 specific activity in artificial volume sample of water density were performed in nine laboratories with the HPGe spectrometry technique. Analysis of the gamma radiation absorption in the sample material confirmed the Compton scattering as the main mechanism of interaction of photons with energy between 300 - 600 keV and 779 - 1408 keV in the most important for environmental monitoring substances (food, water, biological materials, soils). A list of CMCs supported by the comparison is suggested. (authors)

  6. Final report on COOMET.RI(II)-S2.Eu-152 (319/RU/04): Comparison measurements of radionuclide volume sources (Eu-152)

    Energy Technology Data Exchange (ETDEWEB)

    Korostin, S. [All Russian Research Institute for Physical-Technical and Radio-Technical Measurements (VNIIFTRI), Mendeleevo (Russian Federation); Hernandez, T.; Oropesa, P. [Center of Isotopes - Radionuclide Metrology Department (CENTIS-DMR), Habana (Cuba); Arnold, D. [Physikalisch-Technische Bundesanstalt (PTB), Braunschweig (Germany); Evseev, V. [National Scientific Centre ' Institute of Metrology' (NSC IM), Kharkov (Ukraine); Ivanukovich, A.; Milevskiy, V. [Belarusian State Institute of Metrology (BelGIM), Minsk (Belarus); Svec, A. [Slovak Institute of Metrology (SMU), Bratislava (Slovakia); Lapenas, A. [Latvian National Metrology Centre Ltd, Radiation Metrology and Testing Centre (RMTC), Salaspils (Latvia); Andonova, V. [Bulgarian Institute of Metrology - National Centre of Metrology (BIM-NCM), Sofia (Bulgaria); Steiner, V. [Ministry of the Environment - Radiation and Noise Division (ISR-MoE), Jerusalem (Israel)

    2010-04-15

    Measurements of the Eu-152 specific activity in artificial volume sample of water density were performed in nine laboratories with the HPGe spectrometry technique. Analysis of the gamma radiation absorption in the sample material confirmed the Compton scattering as the main mechanism of interaction of photons with energy between 300 - 600 keV and 779 - 1408 keV in the most important for environmental monitoring substances (food, water, biological materials, soils). A list of CMCs supported by the comparison is suggested. (authors)

  7. Status of the Brookhaven National Laboratory (BNL) toroidal volume H- source

    International Nuclear Information System (INIS)

    Alessi, J.G.; Prelec, K.

    1990-01-01

    A volume H - source having a toroidal discharge chamber and conical filter field has been developed. Parametric studies of this source have been in progress for two years. Extraction apertures from 0.5 cm 2 to 1.87 cm 2 have been tried, and an H - current of up to 48 mA has been extracted. The electron-to-H - current ratio in the extracted beam can be as low as 10 for ∼ 25 mA beam was 0.44πmm mrad. When operating with deuterium, the D - output wads 50--60% of the H - current under the same discharge conditions. The addition of cesium to the discharge increased the H - output and decreased the electron current so that at 30 mA of H - , one obtained an electron-to-H - ratio of 1. Using a two gap extractor, with a dipole field in the intermediate electrode, approximately 80% of the extracted electrons could be removed from the primary beam

  8. Cooperative spontaneous emission from volume sources in layered media

    International Nuclear Information System (INIS)

    Nichelatti, E.

    2009-01-01

    The classical theory of radiation from a dipole located inside a microcavity is extended to the case of a volume source placed inside a layered medium. Cooperation phenomena that can take place in the spontaneous emission process are taken into account with an approach based on the theory of spatial coherence. Three cases are considered: noncooperation, long-range cooperation, and short-range cooperation. In all these cases, the expressions found for the out coupled power are analytical. As an application of the theory, an Alq 3 -based organic light emitting diode is analyzed. The optical properties of the device are evaluated and compared for two different types of cathode, one consisting of an Al layer, the other one consisting of an Al/LiF bi-layer. The results found show that the ultra-thin LiF layer significantly improves extraction efficiency [it

  9. Measurement of tumor volumes of hepatocellular carcinoma (HCC) by computed tomography (CT). Correlation with several tumor markers

    Energy Technology Data Exchange (ETDEWEB)

    Yoneshima, Manabu; Sawabu, Norio; Toya, Daishu

    1984-09-01

    Tumor volumes of HCC were measured by CT using planimeter and the clinical value of this measurement was evaluated by comparing several tumor markers. Tumor volumes measured by CT roughly agreed with those measured by angiography. In some cases, volumes from ultrasonography were smaller than those from CT and angiography. Tumor volumes measured by CT correlated significantly with the levels of ..cap alpha..-fetoprotein (AFP) but didn't relate to the presence of hepatoma specific ..gamma..-GTP isoenzyme (novel ..gamma..-GTP) nor to the values and positivities of LAI assay. In small HCCs (<=30 cm/sup 3/), the presence of novel ..gamma..-GTP and the levels of AFP were significantly lower than for larger tumors of HCC, but LAI assay wasn't lower. The non-tumorous volumes and the ratio of the non-tumorous volume to the whole liver volume didn't relate to the tests of liver function except for the presence of ascites.

  10. Volume Measurement Algorithm for Food Product with Irregular Shape using Computer Vision based on Monte Carlo Method

    Directory of Open Access Journals (Sweden)

    Joko Siswantoro

    2014-11-01

    Full Text Available Volume is one of important issues in the production and processing of food product. Traditionally, volume measurement can be performed using water displacement method based on Archimedes’ principle. Water displacement method is inaccurate and considered as destructive method. Computer vision offers an accurate and nondestructive method in measuring volume of food product. This paper proposes algorithm for volume measurement of irregular shape food product using computer vision based on Monte Carlo method. Five images of object were acquired from five different views and then processed to obtain the silhouettes of object. From the silhouettes of object, Monte Carlo method was performed to approximate the volume of object. The simulation result shows that the algorithm produced high accuracy and precision for volume measurement.

  11. Capillary plasma jet: A low volume plasma source for life science applications

    Energy Technology Data Exchange (ETDEWEB)

    Topala, I., E-mail: ionut.topala@uaic.ro, E-mail: tmnagat@ipc.shizuoka.ac.jp [Alexandru Ioan Cuza University of Iasi, Faculty of Physics, Iasi Plasma Advanced Research Center (IPARC), Bd. Carol I No. 11, Iasi 700506 (Romania); Nagatsu, M., E-mail: ionut.topala@uaic.ro, E-mail: tmnagat@ipc.shizuoka.ac.jp [Graduate School of Science and Technology, Shizuoka University, 3-5-1 Johoku, Naka-ku, Hamamatsu 432-8561 (Japan)

    2015-02-02

    In this letter, we present results from multispectroscopic analysis of protein films, after exposure to a peculiar plasma source, i.e., the capillary plasma jet. This plasma source is able to generate very small pulsed plasma volumes, in kilohertz range, with characteristic dimensions smaller than 1 mm. This leads to specific microscale generation and transport of all plasma species. Plasma diagnosis was realized using general electrical and optical methods. Depending on power level and exposure duration, this miniature plasma jet can induce controllable modifications to soft matter targets. Detailed discussions on protein film oxidation and chemical etching are supported by results from absorption, X-ray photoelectron spectroscopy, and microscopy techniques. Further exploitation of principles presented here may consolidate research interests involving plasmas in biotechnologies and plasma medicine, especially in patterning technologies, modified biomolecule arrays, and local chemical functionalization.

  12. Capillary plasma jet: A low volume plasma source for life science applications

    Science.gov (United States)

    Topala, I.; Nagatsu, M.

    2015-02-01

    In this letter, we present results from multispectroscopic analysis of protein films, after exposure to a peculiar plasma source, i.e., the capillary plasma jet. This plasma source is able to generate very small pulsed plasma volumes, in kilohertz range, with characteristic dimensions smaller than 1 mm. This leads to specific microscale generation and transport of all plasma species. Plasma diagnosis was realized using general electrical and optical methods. Depending on power level and exposure duration, this miniature plasma jet can induce controllable modifications to soft matter targets. Detailed discussions on protein film oxidation and chemical etching are supported by results from absorption, X-ray photoelectron spectroscopy, and microscopy techniques. Further exploitation of principles presented here may consolidate research interests involving plasmas in biotechnologies and plasma medicine, especially in patterning technologies, modified biomolecule arrays, and local chemical functionalization.

  13. Procedures for measurement of anisotropy factor of neutron sources

    International Nuclear Information System (INIS)

    Creazolla, P.G.; Camargo, A.; Astuto, A.; Silva, F.; Pereira, W.W.

    2017-01-01

    Radioisotope sources of neutrons allow the production of reference fields for calibration of neutron measurement devices for radioprotection and analysis purposes. When the emission rate of these sources is isotropic, no correction is necessary. However, variations in the source capsule material and variations in the concentration of the emitting material may produce differences in its neutron emission rate relative to the source axis, this effect is called anisotropy. A proposed procedure for measuring the anisotropy factor of the sources belonging to the IRD/LNMRI/LN Neutron Metrology Laboratory using a Precision Long Counter (PLC) detector will be presented

  14. Activity measurements at a waste volume reduction facility

    International Nuclear Information System (INIS)

    Richardson, J.; Lee, D.A.

    1979-01-01

    The monitoring program for Ontario Hydro's radioactive waste management site will be described, several aspects of which will be discussed in detail. The program at this facility includes categorization, volume reduction processing, and storage of solid radioactive wastes from nuclear generating stations of the CANDU type. At the present time, two types of volume reduction process are in operation - incineration and compaction. Following categorization and processing, wastes are stored in in-ground concrete trenches or tile-holes, or in above-ground quadricells. The monitoring program is divided into three areas: public safety, worker safety, and structural integrity. Development projects with respect to the monitoring program have been undertaken to achieve activity accounting for the total waste management program. In particular, a field measurement for the radioactivity content of radioactive ash containers and compacted waste drums

  15. Volume measurement of the horizontal extraocular muscles using magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Nishida, Yasuhiro; Hayashi, Osamu; Nishida, Eri; Murata, Toyotaka; Aoki, Yoshiko; Inatomi, Akihiro; Kani, Kazutaka (Shiga Univ. of Medical Science, Otsu (Japan)); Mabuchi, Norihisa; Furutani, Yoshiaki

    1993-07-01

    The volume of the horizontal extraocular muscles of 11 normal adults and three patients with ophthalmoplegia was measured using magnetic resonance imaging (MRI). The MRI examinations were carried out with a Signa Advantage, 1.5 tesla superconductive magnetic system manufactured by General Electric. This method employs the spin echo technique with a 3.0 mm gapless slice, a 350 ms. repetition time, and a 17.0 ms. echo time. The MRI films were projected and magnified on Kent paper using an overhead projector. Then the shapes of the horizontal extraocular muscles were traced. The volume of the muscles was measured as the total weight of Kent papers which were cut out from muscle shapes in all the slices. The average volume of the normal medial and lateral rectus muscles was 690[+-]87 mm[sup 3] and 734[+-]77 mm[sup 3], respectively. Two cases of peripheral nerve palsy showed typical atrophy of the paretic muscles. A case of orbital myositis showed typical hypertrophy of the inflamed muscles. This measurement may prove useful in the analysis and evaluation of extraocular muscles, especially in ophthalmoplesia.(author).

  16. Drishti: a volume exploration and presentation tool

    Science.gov (United States)

    Limaye, Ajay

    2012-10-01

    Among several rendering techniques for volumetric data, direct volume rendering is a powerful visualization tool for a wide variety of applications. This paper describes the major features of hardware based volume exploration and presentation tool - Drishti. The word, Drishti, stands for vision or insight in Sanskrit, an ancient Indian language. Drishti is a cross-platform open-source volume rendering system that delivers high quality, state of the art renderings. The features in Drishti include, though not limited to, production quality rendering, volume sculpting, multi-resolution zooming, transfer function blending, profile generation, measurement tools, mesh generation, stereo/anaglyph/crosseye renderings. Ultimately, Drishti provides an intuitive and powerful interface for choreographing animations.

  17. A method of measuring a molten metal liquid pool volume

    Science.gov (United States)

    Garcia, G.V.; Carlson, N.M., Donaldson, A.D.

    1990-12-12

    A method of measuring a molten metal liquid pool volume and in particular molten titanium liquid pools, including the steps of (a) generating an ultrasonic wave at the surface of the molten metal liquid pool, (b) shining a light on the surface of a molten metal liquid pool, (c) detecting a change in the frequency of light, (d) detecting an ultrasonic wave echo at the surface of the molten metal liquid pool, and (e) computing the volume of the molten metal liquid. 3 figs.

  18. Fetal lung volume measurement by MRI with high-speed imaging systems

    Energy Technology Data Exchange (ETDEWEB)

    Osada, Hisao; Kaku, Kenshi [Chiba Univ. (Japan). Hospital

    2002-08-01

    Although ultrasonography is widely used for fetal morphologic observation, magnetic resonance imaging (MRI) has gained popularity as a new prenatal diagnostic method with recent introduction of high-speed imaging systems. Infants with lung hypoplasia affecting respiratory function require intensive management starting immediately after birth. Therefore, accurate prenatal differential diagnosis and severity evaluation are extremely important for these fetuses. The aim of this study is to measure fetal lung volume using a computer-based, three-dimensional MRI imaging system and to evaluate the possibility of clinical applications of this procedure. A total of 96 fetuses were evaluated, all were morphologically abnormal, and MRI was done for advanced assessment from 24 to 39 weeks gestation. Three-directional views of fetal chest were imaged by Signa Horizon, 1.5 Tesla, version 5.6 (General Electronics) with the following conditions; coil: TORSO coil, sequence: SSFSE (single shot fast spin echo), slice thickness: 5 mm, and imaging speed: 2 seconds/slice. To calculate the lung volume and create three-dimensional image, the lung area in each slice was traced out, then multiplied using computer image processing. Simultaneously, the volumes of all slices were summed to give the volume of each lung. Linear regression analysis and analysis of covariance (ANCOVA) were used for statistical analyses. In all cases, clear images were obtained, and were adequate for three-dimensional evaluation of the fetal lung. Thirty-five fetuses had poor outcomes, such as intrauterine fetal death, neonatal death, and intensive respiratory care. Regression lines of lung volume versus gestational week were calculated for these fetuses with poor outcome and 61 other fetuses with good outcome. ANCOVA, with gestational week as a covariant, revealed a significant intergroup difference in the lung volume (p<0.001). Similarly, regression lines of lung volume versus fetal body weight estimated by

  19. Gravimetric gas determinations for volume calibration

    International Nuclear Information System (INIS)

    Gibbs, P.W.

    1991-01-01

    Gravimetric measurements of gases is one of the methods available for calibrating gas volumes. By inputting a known quantity of gas and measuring the resulting pressure and temperature, the system volume can be calculated using gas law principles. Historically, this method has been less accurate due to the difficulty in the mass determination. This difficulty comes from several sources. Two examples are the large tare weight of the gas container relative to the weight of gas and the external volume of the gas container relative to the standards. The application of a gravimetric gas determination to tank volume calibrations at the savannah River Site is discussed. Mass determinations on a 25,00 gram gas container were such that a 1500 gram quantity of gas was routinely determined to within ±0.2 gram at the 99% confidence level. In this paper the weighting design and the methods used to address the difficulties of the mass determination are detailed

  20. Inversion of Atmospheric Tracer Measurements, Localization of Sources

    Science.gov (United States)

    Issartel, J.-P.; Cabrit, B.; Hourdin, F.; Idelkadi, A.

    When abnormal concentrations of a pollutant are observed in the atmosphere, the question of its origin arises immediately. The radioactivity from Tchernobyl was de- tected in Sweden before the accident was announced. This situation emphasizes the psychological, political and medical stakes of a rapid identification of sources. In tech- nical terms, most industrial sources can be modeled as a fixed point at ground level with undetermined duration. The classical method of identification involves the cal- culation of a backtrajectory departing from the detector with an upstream integration of the wind field. We were first involved in such questions as we evaluated the ef- ficiency of the international monitoring network planned in the frame of the Com- prehensive Test Ban Treaty. We propose a new approach of backtracking based upon the use of retroplumes associated to available measurements. Firstly the retroplume is related to inverse transport processes, describing quantitatively how the air in a sam- ple originates from regions that are all the more extended and diffuse as we go back far in the past. Secondly it clarifies the sensibility of the measurement with respect to all potential sources. It is therefore calculated by adjoint equations including of course diffusive processes. Thirdly, the statistical interpretation, valid as far as sin- gle particles are concerned, should not be used to investigate the position and date of a macroscopic source. In that case, the retroplume rather induces a straightforward constraint between the intensity of the source and its position. When more than one measurements are available, including zero valued measurements, the source satisfies the same number of linear relations tightly related to the retroplumes. This system of linear relations can be handled through the simplex algorithm in order to make the above intensity-position correlation more restrictive. This method enables to manage in a quantitative manner the

  1. Investigation of a large volume negative hydrogen ion source

    International Nuclear Information System (INIS)

    Courteille, C.; Bruneteau, A.M.; Bacal, M.

    1995-01-01

    The electron and negative ion densities and temperatures are reported for a large volume hybrid multicusp negative ion source. Based on the scaling laws an analysis is made of the plasma formation and loss processes. It is shown that the positive ions are predominantly lost to the walls, although the observed scaling law is n + ∝I 0.57 d . However, the total plasma loss scales linearly with the discharge current, in agreement with the theoretical model. The negative ion formation and loss is also discussed. It is shown that at low pressure (1 mTorr) the negative ion wall loss becomes a significant part of the total loss. The dependence of n - /n e versus the electron temperature is reported. When the negative ion wall loss is negligible, all the data on n - /n e versus the electron temperatures fit a single curve. copyright 1995 American Institute of Physics

  2. Experimental studies for the development of a new method for stroke volume measuring using X-ray videodensitometry

    International Nuclear Information System (INIS)

    Odenthal, H.J.

    1982-01-01

    Quantitative videodensitometry was studied with a view to its possible application as a new, non-invasive method of measuring cardiac stroke volume. To begin with, the accuracy of roentgen volumetric measurements was determined. After this, blood volume variations were measured by densitometry in five animal experiments. The findings were compared with the volumes measured by a flowmeter in the pulmonary artery. The total stroke volume was found to be proportional to the difference between the maximum and mean densitometric volume. A comparison between videodensitometry and other non-invasive methods showed that, in a stable circulatory system, the results of videodensitometry are equally reliable as, or even more reliable than, those of the conventional methods. (orig./MG) [de

  3. Laser driven white light source for BRDF measurement

    DEFF Research Database (Denmark)

    Amdemeskel, Mekbib Wubishet; Thorseth, Anders; Dam-Hansen, Carsten

    2017-01-01

    In this paper, we will present a setup with laser driven light source (LDLS) for measuring a 2D bidirectional reflectance distribution function (BRDF). We have carried out measurements to acquire the BRDF of different samples based on our setup: which consists of a new laser driven broadband light...... source (UV-VIS-NIR), spectroradiometer and sample holder stepper motor in a dark UV-protected environment. Here, we introduced a special kind of light source which has a bright, stable, broad spectral range and well collimated light output to give a very good angular resolution. The experimental results...

  4. Free-volume study of ethylene - vinyl alcohol copolymer evaluated through positronium lifetime measurement

    International Nuclear Information System (INIS)

    Ito, K.; Hong-ling Li; Ujihira, Y.; Nomura, K.; Saito, Y.; Yamamoto, T.; Nishihara, Y.

    2003-01-01

    The free-volume, of size ranging from 0.2 to 0.4 nm in radius, in an ethylene-vinyl alcohol copolymer was estimated using positronium lifetime measurement to elucidate the dependence of oxygen permeability on the free-volume size and fraction, on the ethylene content and on the crystallinity. The permeability and the free-volume fraction with varying the ethylene content were well related and the relation was interpreted based on the free-volume theory near below and above the glass transition temperature. On the other hand, the crystallinity significantly influenced the fraction of the amorphous region, where the free-volume hole exists, along with a slight change of the free-volume size. The variation of the permeability with the crystalline degree cannot be explained from the averaged free-volume fraction estimated by the whole volume of the polymer, but the permeability correlated with the free-volume size apparently. (author)

  5. Portal blood flow volume measurement in schistosomal patients: evaluation of Doppler ultrasonography reproducibility

    International Nuclear Information System (INIS)

    Leao, Alberto Ribeiro de Souza; Santos, Jose Eduardo Mourao; Moulin, Danilo Sales; Shigueoka, David Carlos; D'Ippolito, Giuseppe; Colleoni, Ramiro

    2008-01-01

    Objective: To evaluate the reproducibility of Doppler ultrasonography in the measurement of portal blood flow volume in schistosomal patients. Materials and methods: Prospective, transversal, observational and self-paired study evaluating 21 patients with hepatosplenic schistosomiasis submitted to Doppler ultrasonography performed by three independent observers for measurement of portal blood flow. Pairwise interobserver agreement was calculated by means of the intraclass correlation coefficient, paired t-test and Pearson's correlation coefficient. Results: Interobserver agreement was excellent. Intraclass correlation ranged from 80.6% to 93.0% (IC at 95% [65.3% ; 95.8%]), with the Pearson's correlation coefficient ranging between 81.6% and 92.7% with no statistically significant interobserver difference regarding the mean portal blood flow volume measured by Doppler ultrasonography (p = 0.954 / 0.758 / 0.749). Conclusion: Doppler ultrasonography has demonstrated to be a reliable method for measuring the portal blood flow volume in patients with portal hypertension secondary to schistosomiasis, with a good interobserver agreement. (author)

  6. Portal blood flow volume measurement in schistosomal patients: evaluation of Doppler ultrasonography reproducibility

    Energy Technology Data Exchange (ETDEWEB)

    Leao, Alberto Ribeiro de Souza; Santos, Jose Eduardo Mourao; Moulin, Danilo Sales; Shigueoka, David Carlos; D' Ippolito, Giuseppe [Universidade Federal de Sao Paulo (UNIFESP/EPM), SP (Brazil). Escola Paulista de Medicina. Dept. de Diagnostico por Imagem]. E-mail: ar.leao@uol.com.br; Colleoni, Ramiro [Universidade Federal de Sao Paulo (UNIFESP/EPM), SP (Brazil). Escola Paulista de Medicina. Dept. de Gastroenterologia

    2008-09-15

    Objective: To evaluate the reproducibility of Doppler ultrasonography in the measurement of portal blood flow volume in schistosomal patients. Materials and methods: Prospective, transversal, observational and self-paired study evaluating 21 patients with hepatosplenic schistosomiasis submitted to Doppler ultrasonography performed by three independent observers for measurement of portal blood flow. Pairwise interobserver agreement was calculated by means of the intraclass correlation coefficient, paired t-test and Pearson's correlation coefficient. Results: Interobserver agreement was excellent. Intraclass correlation ranged from 80.6% to 93.0% (IC at 95% [65.3% ; 95.8%]), with the Pearson's correlation coefficient ranging between 81.6% and 92.7% with no statistically significant interobserver difference regarding the mean portal blood flow volume measured by Doppler ultrasonography (p = 0.954 / 0.758 / 0.749). Conclusion: Doppler ultrasonography has demonstrated to be a reliable method for measuring the portal blood flow volume in patients with portal hypertension secondary to schistosomiasis, with a good interobserver agreement. (author)

  7. Densidade global de solos medida com anel volumétrico e por cachimbagem de terra fina seca ao ar Bulk density of soil samples measured in the field and through volume measurement of sieved soil

    Directory of Open Access Journals (Sweden)

    Bernardo Van Raij

    1989-01-01

    Full Text Available Em laboratórios de rotina de fertilidade do solo, a medida de quantidade de terra para análise é feita em volume, mediante utensílios chamados "cachimbos", que permitem medir volumes de terra. Admite-se que essas medidas reflitam a quantidade de terra existente em volume de solo similar em condições de campo. Essa hipótese foi avaliada neste trabalho, por doze amostras dos horizontes A e B de seis perfis de solos. A densidade em condições de campo foi avaliada por anel volumétrico e, no laboratório, por meio de cachimbos de diversos tamanhos. A cachimbagem revelou-se bastante precisa. Os valores de densidade global calculada variaram de 0,63 a 1,46g/cm³ para medidas de campo e de 0,91 a 1,33g/cm³ para medidas com cachimbos. Portanto, a medida de laboratório subestimou valores altos de densidade e deu resultados mais elevados para valores de campo mais baixos.In soil testing laboratories, soil samples for chemical analysis are usually measured by volume, using appropriate measuring spoons. It is tacitly assumed that such measurements would reflect amounts of soil existing in the same volume under field conditions. This hypothesis was tested, using 12 soil samples of the A and B horizons of six soil profiles. Bulk density in the field was evaluated through a cylindrical metal sampler of 50cm³ and in the laboratory using spoons of different sizes. Measurements of soil volumes by spoons were quite precise. Values of bulk density varied between 0.63 and 1.46g/cm³ for field measurements and between 0.91 and 1.33g/cm³ for laboratory measurements with spoons. Thus, laboratory measurements overestimated lower values of bulk densities and underestimated the higher ones.

  8. Planar measurements of soot volume fraction and OH in a JP-8 pool fire

    Energy Technology Data Exchange (ETDEWEB)

    Henriksen, Tara L.; Ring, Terry A.; Eddings, Eric G. [Department of Chemical Engineering, University of Utah, Salt Lake City, UT 84112 (United States); Nathan, Graham J. [School of Mechanical Engineering, University of Adelaide, SA 5005 (Australia); Alwahabi, Zeyad T.; Qamar, Nader [School of Chemical Engineering, University of Adelaide, SA 5005 (Australia)

    2009-07-15

    The simultaneous measurement of soot volume fraction by laser induced incandescence (LII) and qualitative imaging of OH by laser induced fluorescence (LIF) was performed in a JP-8 pool fire contained in a 152 mm diameter pan. Line of sight extinction was used to calibrate the LII system in a laminar flame, and to provide an independent method of measuring average soot volume fraction in the turbulent flame. The presence of soot in the turbulent flame was found to be approximately 50% probable, resulting in high levels of optical extinction, which increased slightly through the flame from approximately 30% near the base, to approximately 50% at the tip. This high soot loading pushes both techniques toward their detection limit. Nevertheless, useful accuracy was obtained, with the LII measurement of apparent extinction in the turbulent flame being approximately 21% lower than a direct measurement, consistent with the influence of signal trapping. The axial and radial distributions of soot volume fraction are presented, along with PDFs of volume fraction, and new insight into the behavior of soot sheets in pool fires are sought from the simultaneous measurements of OH and LII. (author)

  9. Gas Injection And Fast Pressure-Rise Measurements For The Linac4 H− Source

    CERN Document Server

    Mahner, E; Lettry, J; Mattei, S; O'Neil, M; Neupert, H; Pasquino, C; Schmitzer, C

    2013-01-01

    In the era of the Large Hadron Collider, the CERN injector complex comprising the 34 years old Linac2 with its primary proton source, is presently upgraded with a new linear accelerator for H− (Linac4). The design, construction, and test of volume production and cesiated RF-driven H− ion sources is presently ongoing with the final goal of producing an H− beam with 80 mA beam current, 45 keV beam energy, 500 s pulse length, and a repetition rate of 2 Hz. In order to have quantitative information of the hydrogen gas density at the moment of plasma ignition the dynamic vacuum properties of the plasma generator were studied experimentally. We describe the experimental setup and present fast pressure-rise measurements for different parameters of the gas injection system, such as gas species (H2, He, N2, Ar), piezo valve voltage pulse length (200 - 500 s), and injection pressure (400 - 2800 mbar). The obtained data are compared with a conductance model of the plasma generator.

  10. Radioactive Sources in Medicine: Impact of Additional Security Measures

    International Nuclear Information System (INIS)

    Classic, K. L.; Vetter, R. J.; Nelson, K. L.

    2004-01-01

    For many years, medical centers and hospitals have utilized appropriate security measures to prevent theft or unauthorized use of radioactive materials. Recent anxiety about orphan sources and terrorism has heightened concern about diversion of radioactive sources for purposes of constructing a radiological dispersion device. Some medical centers and hospitals may have responded by conducting threat assessments and incorporating additional measures into their security plans, but uniform recommendations or regulations have not been promulgated by regulatory agencies. The International Atomic Energy Agency drafted interim guidance for the purpose of assisting member states in deciding what security measures should be taken for various radioactive sources. The recommendations are aimed at regulators, but suppliers and users also may find the recommendations to be helpful. The purpose of this paper is to describe threat assessments and additional security actions that were taken by one large and one medium-sized medical center and the impact these measures had on operations. Both medical centers possess blood bank irradiators, low-dose-rate therapy sources, and Mo-99/Tc-99m generators that are common to many health care organizations. Other medical devices that were evaluated include high-dose-rate after loaders, intravascular brachytherapy sources, a Co-60 stereotactic surgery unit, and self-shielded irradiators used in biomedical research. This paper will discuss the impact additional security has had on practices that utilize these sources, cost of various security alternatives, and the importance of a security culture in assuring the integrity of security measures without negatively impacting beneficial use of these sources. (Author) 10 refs

  11. Gastrointestinal tract volume measurement method using a compound eye type endoscope

    Science.gov (United States)

    Yoshimoto, Kayo; Yamada, Kenji; Watabe, Kenji; Kido, Michiko; Nagakura, Toshiaki; Takahashi, Hideya; Nishida, Tsutomu; Iijima, Hideki; Tsujii, Masahiko; Takehara, Tetsuo; Ohno, Yuko

    2015-03-01

    We propose an intestine volume measurement method using a compound eye type endoscope. This method aims at assessment of the gastrointestinal function. Gastrointestinal diseases are mainly based on morphological abnormalities. However, gastrointestinal symptoms are sometimes apparent without visible abnormalities. Such diseases are called functional gastrointestinal disorder, for example, functional dyspepsia, and irritable bowel syndrome. One of the major factors for these diseases is abnormal gastrointestinal motility. For the diagnosis of the gastrointestinal tract, both aspects of organic and functional assessment is important. While endoscopic diagnosis is essential for assessment of organic abnormalities, three-dimensional information is required for assessment of the functional abnormalities. Thus, we proposed the three dimensional endoscope system using compound eye. In this study, we forces on the volume of gastrointestinal tract. The volume of the gastrointestinal tract is thought to related its function. In our system, we use a compound eye type endoscope system to obtain three-dimensional information of the tract. The volume can be calculated by integrating the slice data of the intestine tract shape using the obtained three-dimensional information. First, we evaluate the proposed method by known-shape tube. Then, we confirm that the proposed method can measure the tract volume using the tract simulated model. Our system can assess the wall of gastrointestinal tract directly in a three-dimensional manner. Our system can be used for examination of gastric morphological and functional abnormalities.

  12. Comparison of the accuracy of three angiographic methods for calculating left ventricular volume measurement

    International Nuclear Information System (INIS)

    Hu Lin; Cui Wei; Shi Hanwen; Tian Yingping; Wang Weigang; Feng Yanguang; Huang Xueyan; Liu Zhisheng

    2003-01-01

    Objective: To compare the relative accuracy of three methods measuring left ventricular volume by X-ray ventriculography: single plane area-length method, biplane area-length method, and single-plane Simpson's method. Methods: Left ventricular casts were obtained within 24 hours after death from 12 persons who died from non-cardiac causes. The true left ventricular cast volume was measured by water displacement. The calculated volume of the casts was obtained with 3 angiographic methods, i.e., single-plane area-length method, biplane area-length method, and single-plane Simpson's method. Results: The actual average volume of left ventricular casts was (61.17±26.49) ml. The left ventricular volume was averagely (97.50±35.56) ml with single plane area-length method, (90.51±36.33) ml with biplane area-length method, and (65.00± 23.63) ml with single-plane Simpson's method. The left ventricular volumes calculated with single-plane and biplane area-length method were significantly larger than that the actual volumes (P 0.05). The left ventricular volumes calculated with single-plane and biplane area-length method were significantly larger than those calculated with single-plane Simpson's method (P 0.05). The over-estimation of left ventricular volume by single plane area-length method (36.34±17.98) ml and biplane area-length method (29.34±15.59) ml was more obvious than that calculated by single-plane Simpson's method (3.83±8.48) ml. Linear regression analysis showed that there was close correlations between left ventricular volumes calculated with single plane area-length method, biplane area-length method, Simpson's method and the true volume (all r>0.98). Conclusion: Single-plane Simpson's method is more accurate than single plane area-length method and biplane area-length method for left ventricular volume measurement; however, both the single-plane and biplane area-length methods could be used in clinical practice, especially in those imaging modality

  13. Validity of automated measurement of left ventricular ejection fraction and volume using the Philips EPIQ system.

    Science.gov (United States)

    Hovnanians, Ninel; Win, Theresa; Makkiya, Mohammed; Zheng, Qi; Taub, Cynthia

    2017-11-01

    To assess the efficiency and reproducibility of automated measurements of left ventricular (LV) volumes and LV ejection fraction (LVEF) in comparison to manually traced biplane Simpson's method. This is a single-center prospective study. Apical four- and two-chamber views were acquired in patients in sinus rhythm. Two operators independently measured LV volumes and LVEF using biplane Simpson's method. In addition, the image analysis software a2DQ on the Philips EPIQ system was applied to automatically assess the LV volumes and LVEF. Time spent on each analysis, using both methods, was documented. Concordance of echocardiographic measures was evaluated using intraclass correlation (ICC) and Bland-Altman analysis. Manual tracing and automated measurement of LV volumes and LVEF were performed in 184 patients with a mean age of 67.3 ± 17.3 years and BMI 28.0 ± 6.8 kg/m 2 . ICC and Bland-Altman analysis showed good agreements between manual and automated methods measuring LVEF, end-systolic, and end-diastolic volumes. The average analysis time was significantly less using the automated method than manual tracing (116 vs 217 seconds/patient, P Automated measurement using the novel image analysis software a2DQ on the Philips EPIQ system produced accurate, efficient, and reproducible assessment of LV volumes and LVEF compared with manual measurement. © 2017, Wiley Periodicals, Inc.

  14. Measuring air layer volumes retained by submerged floating-ferns Salvinia and biomimetic superhydrophobic surfaces

    Directory of Open Access Journals (Sweden)

    Matthias J. Mayser

    2014-06-01

    Full Text Available Some plants and animals feature superhydrophobic surfaces capable of retaining a layer of air when submerged under water. Long-term air retaining surfaces (Salvinia-effect are of high interest for biomimetic applications like drag reduction in ship coatings of up to 30%. Here we present a novel method for measuring air volumes and air loss under water. We recorded the buoyancy force of the air layer on leaf surfaces of four different Salvinia species and on one biomimetic surface using a highly sensitive custom made strain gauge force transducer setup. The volume of air held by a surface was quantified by comparing the buoyancy force of the specimen with and then without an air layer. Air volumes retained by the Salvinia-surfaces ranged between 0.15 and 1 L/m2 depending on differences in surface architecture. We verified the precision of the method by comparing the measured air volumes with theoretical volume calculations and could find a good agreement between both values. In this context we present techniques to calculate air volumes on surfaces with complex microstructures. The introduced method also allows to measure decrease or increase of air layers with high accuracy in real-time to understand dynamic processes.

  15. Measuring device for strong gamma-ray sources; Dispositif de mesure des fortes sources emettrices {gamma}

    Energy Technology Data Exchange (ETDEWEB)

    Engelman, J; Vagner, J [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1956-07-01

    We are given the description of a hollow argon-filled cylindrical ionisation chamber which is to be used to measure gamma-emitting sources. The instrument is currently used at the Measures Department in routine gauging of some radioelements. Sources are introduced into the central part of the chamber through a remote handling device. Measures are directly registered, it is not worth while removing the source from the container; a deviation of the source has little effect on the ionization current. The chamber was gauged to test such elements as: {sup 198}Au, {sup 60}Co, {sup 192}Ir, {sup 24}Na, {sup 137}Cs. Its measuring power approximately ranges from 100 micro-curies to 5 curies. (author) [French] On decrit une chambre d'ionisation cylindrique creuse, a remplissage d'argon, destinee a la mesure des sources emettrices {gamma}. Cet appareil est utilise couramment par la Section Mesures pour l'etalonnage de routine d'un certain nombre de radioelements. Les sources sont mises en place au centre de la chambre par un dispositif de manipulation a distance. La mesure est faite directement, sans qu'il soit necessaire d'extraire la source de son container; un decentrement de la source n'a en effet pas d'influence sensible sur le courant d'ionisation. Cette chambre d'ionisation a ete etalonnee pour divers radioelements: {sup 198}Au, {sup 60}Co, {sup 192}Ir, {sup 24}Na, {sup 137}Cs. La flamme d'activite mesurable s'etend de 100 microcuries a 5 curies, environ. (auteur)

  16. Molar Volume Analysis of Molten Ni-Al-Co Alloy by Measuring the Density

    Institute of Scientific and Technical Information of China (English)

    XIAO Feng; FANG Liang; FU Yuechao; YANG Lingchuan

    2004-01-01

    The density of molten Ni-Al-Co alloys was measured in the temperature range of 1714~1873K using a modified pycnometric method, and the molar volume of molten alloys was analyzed. The density of molten Ni-Al-Co alloys was found to decrease with increasing temperature and Co concentration in alloys. The molar volume of molten Ni-Al-Co alloys increases with increasing Co concentration in alloys. The molar volume of molten Ni-Al-Co alloys shows a negative deviation from the linear molar volume.

  17. Measurement of Gallbladder Volume with Ultrasonography in Pregnant Women

    Directory of Open Access Journals (Sweden)

    Sait Kapicioglu

    2000-01-01

    Full Text Available Fasting and postprandial gallbladder volumes were investigated using ultrasonography in three groups (10 subjects in each of healthy women: third trimester pregnant women, postpartum women up to 10 days after giving birth and nonpregnant controls. The scans were performed at 09:00 after a 12 h fast. After the basal measurement was taken, gallbladder volumes were rescanned in 15 min intervals for 60 mins. At the end of this period, all volunteers received a standard liquid test meal, and scans were performed again for 1 h. The mean basal gallbladder volume was 22.2±4.2 mL in the nonpregnant (control group. In the third trimester group, the basal volume was 37.8±10.5 mL – 70.5% higher than in the nonpregnant group (P<0.001. In the postpartum group, the mean basal volume was 37.9% lower (27.4±6.5 mL than that of the third trimester group (P<0.02. This basal volume was 23.6% greater than that of the control group (P<0.05. After administration of a test meal, the postprandial gallbladder volumes decreased during the first few minutes compared with baseline values. The volumes decreased by 10.2% to 39.8% (23.5±7.3 to 34.0±10.2; P<0.01 in the third trimester group, by 14.9% to 43.2% (16.6±4.3 to 23.3±5.5; P<0.01, 0.001 in the postpartum group and by 19.2% to 51.6% (11.9±3.5 to 17.9±3.6; P<0.02, 0.05, 0.01, 0.001 in the control group. Postprandial mean gallbladder volumes of the third trimester (P<0.02 and postpartum groups (P<0.02 to 0.01 were significantly different from those of the control group. In conclusion, incomplete emptying of the gallbladder after eating during the third trimester of pregnancy may contribute to cholesterol-gallstone formation, and pregnancy may thus increase the risk of gallstones.

  18. Block volume estimation from the discontinuity spacing measurements of mesozoic limestone quarries, Karaburun Peninsula, Turkey.

    Science.gov (United States)

    Elci, Hakan; Turk, Necdet

    2014-01-01

    Block volumes are generally estimated by analyzing the discontinuity spacing measurements obtained either from the scan lines placed over the rock exposures or the borehole cores. Discontinuity spacing measurements made at the Mesozoic limestone quarries in Karaburun Peninsula were used to estimate the average block volumes that could be produced from them using the suggested methods in the literature. The Block Quality Designation (BQD) ratio method proposed by the authors has been found to have given in the same order of the rock block volume to the volumetric joint count (J(v)) method. Moreover, dimensions of the 2378 blocks produced between the years of 2009 and 2011 in the working quarries have been recorded. Assuming, that each block surfaces is a discontinuity, the mean block volume (V(b)), the mean volumetric joint count (J(vb)) and the mean block shape factor of the blocks are determined and compared with the estimated mean in situ block volumes (V(in)) and volumetric joint count (J(vi)) values estimated from the in situ discontinuity measurements. The established relations are presented as a chart to be used in practice for estimating the mean volume of blocks that can be obtained from a quarry site by analyzing the rock mass discontinuity spacing measurements.

  19. Block Volume Estimation from the Discontinuity Spacing Measurements of Mesozoic Limestone Quarries, Karaburun Peninsula, Turkey

    Directory of Open Access Journals (Sweden)

    Hakan Elci

    2014-01-01

    Full Text Available Block volumes are generally estimated by analyzing the discontinuity spacing measurements obtained either from the scan lines placed over the rock exposures or the borehole cores. Discontinuity spacing measurements made at the Mesozoic limestone quarries in Karaburun Peninsula were used to estimate the average block volumes that could be produced from them using the suggested methods in the literature. The Block Quality Designation (BQD ratio method proposed by the authors has been found to have given in the same order of the rock block volume to the volumetric joint count (Jv method. Moreover, dimensions of the 2378 blocks produced between the years of 2009 and 2011 in the working quarries have been recorded. Assuming, that each block surfaces is a discontinuity, the mean block volume (Vb, the mean volumetric joint count (Jvb and the mean block shape factor of the blocks are determined and compared with the estimated mean in situ block volumes (Vin and volumetric joint count (Jvi values estimated from the in situ discontinuity measurements. The established relations are presented as a chart to be used in practice for estimating the mean volume of blocks that can be obtained from a quarry site by analyzing the rock mass discontinuity spacing measurements.

  20. Thigh muscle volume predicted by anthropometric measurements and correlated with physical function in the older adults.

    Science.gov (United States)

    Chen, B B; Shih, T T F; Hsu, C Y; Yu, C W; Wei, S Y; Chen, C Y; Wu, C H; Chen, C Y

    2011-06-01

    (1) to correlate thigh muscle volume measured by magnetic resonance image (MRI) with anthropometric measurements and physical function in elderly subjects; (2) to predict MRI-measured thigh muscle volume using anthropometric measurements and physical functional status in elderly subjects. Cross-sectional, nonrandomized study. Outpatient clinic in Taiwan. Sixty-nine elderly subjects (33 men and 36 women) aged 65 and older. The anthropometric data (including body height, body weight, waist size, and thigh circumference), physical activity and function (including grip strength, bilateral quadriceps muscle power, the up and go test, chair rise, and five meters walk time) and bioelectrical impedance analysis data (including total body fat mass, fat-free mass, and predictive muscle size) were measured. MRI-measured muscle volume of both thighs was used as the reference standard. The MRI-measured thigh volume was positively correlated with all anthropometric data, quadriceps muscle power and the up and go test as well as fat-free mass and predictive muscle mass, whereas it was negatively associated with age and walk time. In predicting thigh muscle volume, the variables of age, gender, body weight, and thigh circumference were significant predictors in the linear regression model: Muscle volume (cm3) =4226.3-42.5 × Age (year)-955.7 × gender (male=1, female=2) + 45.9 × body weight(kg) + 60.0 × thigh circumference (cm) (r2 = 0.745, P estimate = 581.6 cm3). The current work provides evidence of a strong relationship between thigh muscle volume and physical function in the elderly. We also developed a prediction equation model using anthropometric measurements. This model is a simple and noninvasive method for everyday clinical practice and follow-up.

  1. The error analysis of Lobular and segmental division of right liver by volume measurement.

    Science.gov (United States)

    Zhang, Jianfei; Lin, Weigang; Chi, Yanyan; Zheng, Nan; Xu, Qiang; Zhang, Guowei; Yu, Shengbo; Li, Chan; Wang, Bin; Sui, Hongjin

    2017-07-01

    The aim of this study is to explore the inconsistencies between right liver volume as measured by imaging and the actual anatomical appearance of the right lobe. Five healthy donated livers were studied. The liver slices were obtained with hepatic segments multicolor-infused through the portal vein. In the slices, the lobes were divided by two methods: radiological landmarks and real anatomical boundaries. The areas of the right anterior lobe (RAL) and right posterior lobe (RPL) on each slice were measured using Photoshop CS5 and AutoCAD, and the volumes of the two lobes were calculated. There was no statistically significant difference between the volumes of the RAL or RPL as measured by the radiological landmarks (RL) and anatomical boundaries (AB) methods. However, the curves of the square error value of the RAL and RPL measured using CT showed that the three lowest points were at the cranial, intermediate, and caudal levels. The U- or V-shaped curves of the square error rate of the RAL and RPL revealed that the lowest value is at the intermediate level and the highest at the cranial and caudal levels. On CT images, less accurate landmarks were used to divide the RAL and RPL at the cranial and caudal layers. The measured volumes of hepatic segments VIII and VI would be less than their true values, and the measured volumes of hepatic segments VII and V would be greater than their true values, according to radiological landmarks. Clin. Anat. 30:585-590, 2017. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  2. Optimization of the testing volumes with respect to neutron flux levels in the two-target high flux D-Li neutron source for the international fusion materials irradiation facility

    International Nuclear Information System (INIS)

    Kelleher, W.P.; Varsamis, G.L.

    1989-01-01

    An economic and fusion-relevant source of high-energy neutrons is an essential element in the fusion nuclear technology and development program. This source can be generated by directing a high energy deuteron beam onto a flowing liquid lithium target, producing neutrons via the D-Lithium stripping reaction. Previous work on this type of source concentrated on a design employing one deuteron beam of modest amperage. This design was shown to have a relatively small testing volume with high flux gradients and was therefor considered somewhat unattractive from a materials testing standpoint. A design using two lithium targets and two high-amperage beams has recently been proposed. This two beam design has been examined in an effort to maximize the test volume while minimizing the flux gradients and minimizing the effect of radiation damage on one target due to the other. A spatial, energy and angle dependent neutron source modeling the D-Lithium source was developed. Using this source, a 3-dimensional map of uncollided flux within the test volume was calculated. The results showed that the target separation has little effect on the available experimental volume and that a testing volume of ∼35 liters is available with a volume averaged flux above 10 14 n/cm 2 /s. The collided flux within the test volume was then determined by coupling the source model with a Monte Carlo code. The spectral effects of the high-energy tail in the flux were examined and evaluated as to possible effects on materials response. Calculations comparing the radiation damage to materials from the D-Lithium source to that cause by a standard DT fusion first-wall neutron flux spectrum showed that the number of appm and dpa, as well as the ratio appm/dpa and dpa/MW/m 2 are within 30% for the two sources. 8 refs., 8 figs

  3. Advanced Neutron Source enrichment study -- Volume 1: Main report. Final report, Revision 12/94

    International Nuclear Information System (INIS)

    Bari, R.A.; Ludewig, H.; Weeks, J.

    1994-01-01

    A study has been performed of the impact on performance of using low enriched uranium (20% 235 U) or medium enriched uranium (35% 235 U) as an alternative fuel for the Advanced Neutron Source, which is currently designed to use uranium enriched to 93% 235 U. Higher fuel densities and larger volume cores were evaluated at the lower enrichments in terms of impact on neutron flux, safety, safeguards, technical feasibility, and cost. The feasibility of fabricating uranium silicide fuel at increasing material density was specifically addressed by a panel of international experts on research reactor fuels. The most viable alternative designs for the reactor at lower enrichments were identified and discussed. Several sensitivity analyses were performed to gain an understanding of the performance of the reactor at parametric values of power, fuel density, core volume, and enrichment that were interpolations between the boundary values imposed on the study or extrapolations from known technology. Volume 2 of this report contains 26 appendices containing results, meeting minutes, and fuel panel presentations

  4. Laser-induced incandescence: Towards quantitative soot volume fraction measurements

    Energy Technology Data Exchange (ETDEWEB)

    Tzannis, A P; Wienbeucker, F; Beaud, P; Frey, H -M; Gerber, T; Mischler, B; Radi, P P [Paul Scherrer Inst. (PSI), Villigen (Switzerland)

    1999-08-01

    Laser-Induced Incandescence has recently emerged as a versatile tool for measuring soot volume fraction in a wide range of combustion systems. In this work we investigate the essential features of the method. LII is based on the acquisition of the incandescence of soot when heated through a high power laser pulse. Initial experiments have been performed on a model laboratory flame. The behaviour of the LII signal is studied experimentally. By applying numerical calculations we investigate the possibility to obtain two-dimensional soot volume fraction distributions. For this purpose a combination of LII with other techniques is required. This part is discussed in some extent and the future work is outlined. (author) 4 figs., 3 refs.

  5. Gamma ray densitometry techniques for measuring of volume fractions

    International Nuclear Information System (INIS)

    Affonso, Renato Raoni Werneck; Silva, Ademir Xavier da; Salgado, Cesar Marques

    2015-01-01

    Knowledge of the volume fraction in a multiphase flow is of key importance in predicting the performance of many systems and processes. It is therefore an important parameter to characterize such flows. In the context of nuclear techniques, the gamma ray densitometry is promising and this is due to its non-invasive characteristics and very reliable results. It is used in several applications for multiphase flows (water-oil-air), which are employed tools such as: computational fluid dynamics, artificial neural networks and statistical methods of radiation transport, such as the Monte Carlo method. Based on the gamma radiation techniques for measurements of volume fractions, the aim of this paper is to present several techniques developed for this purpose. (author)

  6. Gamma ray densitometry techniques for measuring of volume fractions

    Energy Technology Data Exchange (ETDEWEB)

    Affonso, Renato Raoni Werneck; Silva, Ademir Xavier da; Salgado, Cesar Marques, E-mail: raoniwa@yahoo.com.br, E-mail: ademir@nuclear.ufrj.br, E-mail: otero@ien.gov.br [Instituto de Engenharia Nuclear (IEN/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2015-07-01

    Knowledge of the volume fraction in a multiphase flow is of key importance in predicting the performance of many systems and processes. It is therefore an important parameter to characterize such flows. In the context of nuclear techniques, the gamma ray densitometry is promising and this is due to its non-invasive characteristics and very reliable results. It is used in several applications for multiphase flows (water-oil-air), which are employed tools such as: computational fluid dynamics, artificial neural networks and statistical methods of radiation transport, such as the Monte Carlo method. Based on the gamma radiation techniques for measurements of volume fractions, the aim of this paper is to present several techniques developed for this purpose. (author)

  7. Spectroscopic measurements of an H- ion source discharge

    International Nuclear Information System (INIS)

    Keller, R.; Smith, H.V. Jr.

    1985-01-01

    Spectral emission lines from an H - Penning surface-plasma source (SPS), the 4X source, are examined in the visible and near ultraviolet. Electron distribution temperatures are deduced from integral line-strength measurements. These temperatures are surprisingly low, about 0.5 eV. Electron density values of about 1.5 x 10 14 cm -3 and H-atom energies between 2 and 2.6 eV are determined from the measured Balmer-line profiles. Assuming the H - energy is identical to the H-atom energy, an emittance limit of 0.006 π x cm x mrad is deduced for this source with a 5.4-mm aperture

  8. Can endocranial volume be estimated accurately from external skull measurements in great-tailed grackles (Quiscalus mexicanus?

    Directory of Open Access Journals (Sweden)

    Corina J. Logan

    2015-06-01

    Full Text Available There is an increasing need to validate and collect data approximating brain size on individuals in the field to understand what evolutionary factors drive brain size variation within and across species. We investigated whether we could accurately estimate endocranial volume (a proxy for brain size, as measured by computerized tomography (CT scans, using external skull measurements and/or by filling skulls with beads and pouring them out into a graduated cylinder for male and female great-tailed grackles. We found that while females had higher correlations than males, estimations of endocranial volume from external skull measurements or beads did not tightly correlate with CT volumes. We found no accuracy in the ability of external skull measures to predict CT volumes because the prediction intervals for most data points overlapped extensively. We conclude that we are unable to detect individual differences in endocranial volume using external skull measurements. These results emphasize the importance of validating and explicitly quantifying the predictive accuracy of brain size proxies for each species and each sex.

  9. Measurement of lung volume by lung perfusion scanning using SPECT and prediction of postoperative respiratory function

    International Nuclear Information System (INIS)

    Andou, Akio; Shimizu, Nobuyosi; Maruyama, Shuichiro

    1992-01-01

    Measurement of lung volume by lung perfusion scanning using single photon emission computed tomography (SPECT) and its usefulness for the prediction of respiratory function after lung resection were investigated. The lung volumes calculated in 5 patients by SPECT (threshold level 20%) using 99m Tc-macroaggregated albumin (MAA), related very closely to the actually measured lung volumes. This results prompted us to calculate the total lung volume and the volume of the lobe to be resected in 18 patients with lung cancer by SPECT. Based on the data obtained, postoperative respiratory function was predicted. The predicted values of forced vital capacity (FVC), forced expiratory volume (FEV 1.0 ), and maximum vital volume (MVV) showed closer correlations with the actually measured postoperative values (FVC, FEV 1.0 , MVV : r=0.944, r=0.917, r=0.795 respectively), than the values predicted by the ordinary lung perfusion scanning. This method facilitates more detailed evaluation of local lung function on a lobe-by-lobe basis, and can be applied clinically to predict postoperative respiratory function. (author)

  10. Air Pollution Translations: A Bibliography with Abstracts - Volume 4.

    Science.gov (United States)

    Environmental Protection Agency, Research Triangle Park, NC. Air Pollution Technical Information Center.

    This volume is the fourth in a series of compilations presenting abstracts and indexes of translations of technical air pollution literature. The entries are grouped into 12 subject categories: Emission Sources, Control Methods, Measurement Methods, Air Quality Measurements, Atmospheric Interaction, Basic Science and Technology, Effects--Human…

  11. Three-dimensional sonographic measurement of normal fetal brain volume during the second half of pregnancy

    NARCIS (Netherlands)

    N.M. Roelfsema; W.C.J. Hop (Wim); S.M. Boito; J.W. Wladimiroff (Juriy)

    2004-01-01

    textabstractObjectives: This study was undertaken to develop a three-dimensional (3D) ultrasound method of measuring fetal brain volume. Study design: Serial 3D sonographic measurements of fetal brain volume were made in 68 normal singleton pregnancies at 18 to 34 weeks of gestation. A comparison

  12. The bigger, the better? Volume measurements of parasites and hosts

    DEFF Research Database (Denmark)

    Nagler, Christina; Hörnig, Marie K.; Haug, Joachim T.

    2017-01-01

    ), and a trophic, root like system situated inside the hosts body (the interna). Parasitism results in the castration of their hosts, achieved by absorbing the entire reproductive energy of the host. Thus, the ratio of the host and parasite sizes is crucial for the understanding of the parasite's energetic cost......Rhizocephala, a group of parasitic castrators of other crustaceans, shows remarkable morphological adaptations to their lifestyle. The adult female parasite consists of a body that can be differentiated into two distinct regions: a sac-like structure containing the reproductive organs (the externa....... Using advanced imaging methods (micro-CT in conjunction with 3D modeling), we measured the volume of parasitic structures (externa, interna, egg mass, egg number, visceral mass) and the volume of the entire host. Our results show positive correlations between the volume of (1) entire rhizocephalan...

  13. Advisory Committee on human radiation experiments. Final report, Supplemental Volume 2. Sources and documentation

    International Nuclear Information System (INIS)

    1995-01-01

    This volume and its appendixes supplement the Advisory Committee's final report by reporting how we went about looking for information concerning human radiation experiments and intentional releases, a description of what we found and where we found it, and a finding aid for the information that we collected. This volume begins with an overview of federal records, including general descriptions of the types of records that have been useful and how the federal government handles these records. This is followed by an agency-by-agency account of the discovery process and descriptions of the records reviewed, together with instructions on how to obtain further information from those agencies. There is also a description of other sources of information that have been important, including institutional records, print resources, and nonprint media and interviews. The third part contains brief accounts of ACHRE's two major contemporary survey projects (these are described in greater detail in the final report and another supplemental volume) and other research activities. The final section describes how the ACHRE information-nation collections were managed and the records that ACHRE created in the course of its work; this constitutes a general finding aid for the materials deposited with the National Archives. The appendices provide brief references to federal records reviewed, descriptions of the accessions that comprise the ACHRE Research Document Collection, and descriptions of the documents selected for individual treatment. Also included are an account of the documentation available for ACHRE meetings, brief abstracts of the almost 4,000 experiments individually described by ACHRE staff, a full bibliography of secondary sources used, and other information

  14. Advisory Committee on human radiation experiments. Final report, Supplemental Volume 2. Sources and documentation

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-01-01

    This volume and its appendixes supplement the Advisory Committee`s final report by reporting how we went about looking for information concerning human radiation experiments and intentional releases, a description of what we found and where we found it, and a finding aid for the information that we collected. This volume begins with an overview of federal records, including general descriptions of the types of records that have been useful and how the federal government handles these records. This is followed by an agency-by-agency account of the discovery process and descriptions of the records reviewed, together with instructions on how to obtain further information from those agencies. There is also a description of other sources of information that have been important, including institutional records, print resources, and nonprint media and interviews. The third part contains brief accounts of ACHRE`s two major contemporary survey projects (these are described in greater detail in the final report and another supplemental volume) and other research activities. The final section describes how the ACHRE information-nation collections were managed and the records that ACHRE created in the course of its work; this constitutes a general finding aid for the materials deposited with the National Archives. The appendices provide brief references to federal records reviewed, descriptions of the accessions that comprise the ACHRE Research Document Collection, and descriptions of the documents selected for individual treatment. Also included are an account of the documentation available for ACHRE meetings, brief abstracts of the almost 4,000 experiments individually described by ACHRE staff, a full bibliography of secondary sources used, and other information.

  15. The status of DESY H- - sources

    International Nuclear Information System (INIS)

    Peters, J.

    1996-01-01

    Two different types of H - sources are operated at DESY, a magnetron source and an rf- driven volume source. H - sources for HERA have to run for long uninterrupted periods with a low duty factor and a high reliability. Several necessary improvements are under construction for our rf - driven volume source. The status of both our magnetron and our volume source will be discussed and the first LINAC III experiment with the rf-driven volume source will be presented. (author)

  16. A NEW RECIPE FOR OBTAINING CENTRAL VOLUME DENSITIES OF PRESTELLAR CORES FROM SIZE MEASUREMENTS

    International Nuclear Information System (INIS)

    Tassis, Konstantinos; Yorke, Harold W.

    2011-01-01

    We propose a simple analytical method for estimating the central volume density of prestellar molecular cloud cores from their column density profiles. Prestellar cores feature a flat central part of the column density and volume density profiles of the same size indicating the existence of a uniform-density inner region. The size of this region is set by the thermal pressure force which depends only on the central volume density and temperature of the core, and can provide a direct measurement of the central volume density. Thus, a simple length measurement can immediately yield a central density estimate independent of any dynamical model for the core and without the need for fitting. Using the radius at which the column density is 90% of the central value as an estimate of the size of the flat inner part of the column density profile yields an estimate of the central volume density within a factor of two for well-resolved cores.

  17. Volume and leak measurements during neonatal CPAP in neonates

    OpenAIRE

    Fischer, Hendrik S.

    2011-01-01

    As yet, little is known about the effects of air leakages during CPAP in newborns. The present doctoral dissertation investigates tidal volume and leak measurements during nasal continuous positive airway pressure in neonates using a commercial ventilatory device. Investigations include in vitro studies, modelling and computer simulation as well as a clinical randomized cross-over trial in neonates.

  18. Acidic precipitation. Volume 3: Sources, deposition, and canopy interactions. Advances in environmental science

    Energy Technology Data Exchange (ETDEWEB)

    Lindberg, S.E.; Page, A.L.; Norton, S.A. (eds.)

    1990-01-01

    As has been the case with many environmental issues of the twentieth century, acidic precipitation has its origin in emissions to the atmosphere of numerous compounds from both natural and man-made sources. This volume emphasizes the atmospheric aspects of acidic precipitation and all that this term has come to include (e.g. toxic gases such as ozone, trace metals, aluminum, and oxides of nitrogen). It progresses from emissions of the precursors of acidic precipitation to their eventual deposition on environmental surfaces. The chapters describe the sources of acidic and basic airborne substances, their interactions in the atmosphere and with rain droplets, and their reactions with other airborne constituents such as aluminum and other metals. Also discussed are the use of metals as tracers of sources of the precursors of acidic precipitation and as tracers of historical deposition rates, the processes controlling the removal of airborne material as dry deposition and deposition interactions with the forest canopy, and past and future trends in atmospheric emissions and options for their abatement.

  19. Impact of the time window on plasma volume measurement with indocyanine green

    International Nuclear Information System (INIS)

    Jacob, M; Chappell, D; Conzen, P; Finsterer, U; Rehm, M; Krafft, A; Becker, B F

    2008-01-01

    Recent reports have questioned the accuracy of the indocyanine green dilution technique for measuring plasma volume. Our objective was to evaluate the impact of different time windows for monoexponential extrapolation. We retrospectively analysed 31 indocyanine green decay curves to investigate the problem in principle (group 1) and prospectively performed another 21 plasma volume measurements to estimate its practical impact (group 2). To monoexponentially extrapolate back to the specific extinction at the time of dye injection, two different time windows were applied to each decay curve, comparing the plasma volumes resulting from sampling within a short (≤5 min) versus a longer (>5 min) period of time. Extrapolating back from the longer period led to a higher apparent plasma volume relative to the shorter period in both groups, the difference being 348 ± 171 ml (group 1) and 384 ± 131 ml (group 2; mean ± SD; p < 0.05 each). This result was due to a reliable monoexponentiality of decay only up to the 5th min after dye injection. Thus, to estimate the initial distribution space of indocyanine green via monoexponential extrapolation, the first linear kinetic of indocyanine green decay should be taken

  20. Low contrast medium-volume third-generation dual-source computed tomography angiography for transcatheter aortic valve replacement planning

    Energy Technology Data Exchange (ETDEWEB)

    Felmly, Lloyd M. [Medical University of South Carolina, Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Charleston, SC (United States); Medical University of South Carolina, Division of Cardiothoracic Surgery, Department of Surgery, Charleston, SC (United States); De Cecco, Carlo N.; Varga-Szemes, Akos; McQuiston, Andrew D. [Medical University of South Carolina, Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Charleston, SC (United States); Schoepf, U.J.; Litwin, Sheldon E.; Bayer, Richard R. [Medical University of South Carolina, Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Charleston, SC (United States); Medical University of South Carolina, Division of Cardiology, Department of Medicine, Charleston, SC (United States); Mangold, Stefanie [Medical University of South Carolina, Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Charleston, SC (United States); University Hospital of Tuebingen, Department of Diagnostic and Interventional Radiology, Tuebingen (Germany); Vogl, Thomas J. [University Hospital Frankfurt, Department of Diagnostic and Interventional Radiology, Frankfurt (Germany); Wichmann, Julian L. [Medical University of South Carolina, Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Charleston, SC (United States); University Hospital Frankfurt, Department of Diagnostic and Interventional Radiology, Frankfurt (Germany)

    2017-05-15

    To investigate feasibility, image quality and safety of low-tube-voltage, low-contrast-volume comprehensive cardiac and aortoiliac CT angiography (CTA) for planning transcatheter aortic valve replacement (TAVR). Forty consecutive TAVR candidates prospectively underwent combined CTA of the aortic root and vascular access route (270 mgI/ml iodixanol). Patients were assigned to group A (second-generation dual-source CT [DSCT], 100 kV, 60 ml contrast, 4.0 ml/s flow rate) or group B (third-generation DSCT, 70 kV, 40 ml contrast, 2.5 ml/s flow rate). Vascular attenuation, noise, signal-to-noise (SNR) and contrast-to-noise ratios (CNR) were compared. Subjective image quality was assessed by two observers. Estimated glomerular filtration (eGFR) at CTA and follow-up were measured. Besides a higher body-mass-index in group B (24.8±3.8 kg/m{sup 2} vs. 28.1±5.4 kg/m{sup 2}, P=0.0339), patient characteristics between groups were similar (P≥0.0922). Aortoiliac SNR (P=0.0003) was higher in group B. Cardiac SNR (P=0.0003) and CNR (P=0.0181) were higher in group A. Subjective image quality was similar (P≥0.213) except for aortoiliac image noise (4.42 vs. 4.12, P=0.0374). TAVR-planning measurements were successfully obtained in all patients. There were no significant changes in eGFR among and between groups during follow-up (P≥0.302). TAVR candidates can be safely and effectively evaluated by a comprehensive CTA protocol with low contrast volume using low-tube-voltage acquisition. (orig.)

  1. Low contrast medium-volume third-generation dual-source computed tomography angiography for transcatheter aortic valve replacement planning

    International Nuclear Information System (INIS)

    Felmly, Lloyd M.; De Cecco, Carlo N.; Varga-Szemes, Akos; McQuiston, Andrew D.; Schoepf, U.J.; Litwin, Sheldon E.; Bayer, Richard R.; Mangold, Stefanie; Vogl, Thomas J.; Wichmann, Julian L.

    2017-01-01

    To investigate feasibility, image quality and safety of low-tube-voltage, low-contrast-volume comprehensive cardiac and aortoiliac CT angiography (CTA) for planning transcatheter aortic valve replacement (TAVR). Forty consecutive TAVR candidates prospectively underwent combined CTA of the aortic root and vascular access route (270 mgI/ml iodixanol). Patients were assigned to group A (second-generation dual-source CT [DSCT], 100 kV, 60 ml contrast, 4.0 ml/s flow rate) or group B (third-generation DSCT, 70 kV, 40 ml contrast, 2.5 ml/s flow rate). Vascular attenuation, noise, signal-to-noise (SNR) and contrast-to-noise ratios (CNR) were compared. Subjective image quality was assessed by two observers. Estimated glomerular filtration (eGFR) at CTA and follow-up were measured. Besides a higher body-mass-index in group B (24.8±3.8 kg/m 2 vs. 28.1±5.4 kg/m 2 , P=0.0339), patient characteristics between groups were similar (P≥0.0922). Aortoiliac SNR (P=0.0003) was higher in group B. Cardiac SNR (P=0.0003) and CNR (P=0.0181) were higher in group A. Subjective image quality was similar (P≥0.213) except for aortoiliac image noise (4.42 vs. 4.12, P=0.0374). TAVR-planning measurements were successfully obtained in all patients. There were no significant changes in eGFR among and between groups during follow-up (P≥0.302). TAVR candidates can be safely and effectively evaluated by a comprehensive CTA protocol with low contrast volume using low-tube-voltage acquisition. (orig.)

  2. Clinical significance of computed tomography in the measurement of thyroid volume after operation for Basedow's disease

    International Nuclear Information System (INIS)

    Kasuga, Yoshio; Miyakawa, Makoto; Sugenoya, Akira

    1986-01-01

    The postoperative volume of the thyroid glands was measured using computed tomography (CT) in 16 patients with Basedow's disease. In the group which had normal postoperative thyroid function and did not need to receive T 4 , CT showed increase of thyroid volume. In three of the four patients who needed to receive it, CT showed decreased thyroid volume, as compared with that immediately after operation. CT has proved to serve as a tool for measuring postoperative thyroid volume for Basedow's disease in relation to postoperative prognosis. (Namekawa, K.)

  3. The accuracy of ventricular volume measurement and the optimal slice thickness by using multislice helical computed tomography

    International Nuclear Information System (INIS)

    Cui Wei; Guo Yuyin

    2005-01-01

    Objective: To determine the optimal slice thickness for ventricular volume measurement by tomographic multislice Simpson's method and to evaluate the accuracy of ventricular volume measured by multislice helical computed tomography (MSCT) in human ventricular casts. Methods: Fourteen human left ventricular (LV) and 15 right ventricular (RV) casts were scanned with MSCT scanner by using a scanning protocol similar to clinical practice. A series of LV and RV short-axis images were reconstructed with slice thickness of 2 mm, 3.5 mm, 5 mm, 7 mm, and 10 mm, respectively. Multislice Simpson's method was used to calculate LV and RV volumes and true cast volume was determined by water displacement. Results: The true LV and RV volumes were (55.57 ± 28.91) ml, and (64.23 ± 24.51) ml, respectively. The calculated volumes from different slice thickness ranged from (58.78 ± 28.93) ml to (68.15 ± 32.57) ml for LV casts, and (74.45 ± 27.81) ml to (88.14 ± 32.91) ml for RV casts, respectively. Both the calculated LV and RV volumes correlated closely with the corresponding true volumes (all r > 0.95, P<0.001), but overestimated the corresponding true volume by (3.21 ± 5.95) to (12.58 ± 8.56) ml for LV and (10.22 ± 8.45) to (23.91 ± 12.24) ml for RV (all P<0.01). There was a close correlation between the overestimation and the selected slice thickness for both LV and RV volume measurements (r=0.998 and 0.996, P<0.001). However, when slice thickness was reduced to 5.0 mm, the overestimation became nonsignificant for slice thickness through 2.0 mm to 5.0 mm, and also for both LV and RV volume measurements. Conclusion: Both LV and RV volumes can be accurately calculated with MSCT. A 5 mm slice thickness is enough and most efficient for accurate measurement of LV and RV volume. (authors)

  4. Study of liver volume measurement and its clinical application for liver transplantation using multiple-slice spiral CT

    International Nuclear Information System (INIS)

    Peng Zhiyi; Yu Zhefeng; Kuang Pingding; Xiao Shengxiang; Huang Dongsheng; Zheng Shusen; Wu Jian

    2004-01-01

    Objective: To study the accuracy of liver volume measurement using MSCT and its application in liver transplantation. Methods: (1) Experimental study. Ten pig livers were scanned using MSCT with two collimations (3.2 mm and 6.5 mm) and pitch 1.25. Semi-automatic method was used to reconstruct 3D liver models to measure the liver volume. (2) Clinical study. Twenty-three patients received MSCT scan with collimation of 6.5 mm before liver transplantation. Same method was used to calculate the liver volume and the measurement was repeated by the same observer after 1 month. Results: (1) Experimental study. Actual liver volumes were (1134.1 ± 288.0) ml. Liver volumes by MSCT with two collimations were (1125.0 ± 282.5) ml (3.2 mm) and (1101.6 ± 277.6) ml (6.5 mm). The accuracy was (99.5 ± 0.8)% and (97.4 ± 0.8)%, respectively. Both showed same good agreement with actual liver volume: r=0.999, P<0.01 (2) Clinical study. Actual liver volumes were (1455.7±730.0) ml. Liver volume by MSCT was (1462.7 ± 774.1) ml. The accuracy was (99.5±9.6)%, r=0.986, P<0.01. Liver volume measured again was (1449.4 ± 768.9) ml, r=0.991 (P<0.01). Conclusion: MSCT can assess the liver volume correctly, and could be used as a routine step for evaluations before liver transplantation

  5. Metopic synostosis: Measuring intracranial volume change following fronto-orbital advancement using three-dimensional photogrammetry.

    Science.gov (United States)

    Freudlsperger, Christian; Steinmacher, Sahra; Bächli, Heidi; Somlo, Elek; Hoffmann, Jürgen; Engel, Michael

    2015-06-01

    There is still disagreement regarding the intracranial volumes of patients with metopic synostosis compared with healthy patients. This study aimed to compare the intracranial volume of children with metopic synostosis before and after surgery to an age- and sex-matched control cohort using three-dimensional (3D) photogrammetry. Eighteen boys with metopic synostosis were operated on using standardized fronto-orbital advancement. Frontal, posterior and total intracranial volumes were measured exactly 1 day pre-operatively and 10 days post-operatively, using 3D photogrammetry. To establish an age- and sex-matched control group, the 3D photogrammetric data of 634 healthy boys between the ages of 3 and 13 months were analyzed. Mean age at surgery was 9 months (SD 1.7). Prior to surgery, boys with metopic synostosis showed significantly reduced frontal and total intracranial volumes compared with the reference group, but similar posterior volumes. After surgery, frontal and total intracranial volumes did not differ statistically from the control group. As children with metopic synostosis showed significantly smaller frontal and total intracranial volumes compared with an age- and sex-matched control group, corrective surgery should aim to achieve volume expansion. Furthermore, 3D photogrammetry provides a valuable alternative to CT scans in the measurement of intracranial volume in children with metopic synostosis, which significantly reduces the amount of radiation exposure to the growing brain. Copyright © 2015 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  6. Advanced Photon Source research: Volume 1, Number 1, April 1998

    International Nuclear Information System (INIS)

    1998-04-01

    The following articles are included in this publication: (1) The Advanced Photon Source: A Brief Overview; (2) MAD Analysis of FHIT at the Structural Biology Center; (3) Advances in High-Energy-Resolution X-ray Scattering at Beamline 3-ID; (4) X-ray Imaging and Microspectroscopy of the Mycorrhyizal Fungus-Plant Symbiosis; (5) Measurement and Control of Particle-beam Trajectories in the Advanced Photon Storage Ring; (6) Beam Acceleration and Storage at the Advanced Photon Source; and (7) Experimental Facilities Operations and Current Status

  7. Measurement of synovial fluid volume using urea.

    Science.gov (United States)

    Kraus, V B; Stabler, T V; Kong, S Y; Varju, G; McDaniel, G

    2007-10-01

    To examine the utility of using urea concentrations for determining Synovial Fluid (SF) joint volume in effused and non-effused joints. Knee joint SF was aspirated from 159 human study participants with symptomatic osteoarthritis of at least one knee either directly (165 knees) or by lavage (110 knees). Serum was obtained immediately prior to SF aspiration. Participants were asked to rate individual knee pain, aching or stiffness. SF and serum urea levels were determined using a specific enzymatic method run on an automated CMA600 analyzer. Cell counts were performed on direct SF aspirates when volume permitted. The formula for calculating SF joint volume was as follows: V(j)=C(D)(V(I))/(C-C(D)) with V(j)=volume of SF in entire joint, C(D)=concentration of urea in diluted (lavage) SF, V(I)=volume of saline injected into joint, and C=concentration of urea in undiluted (neat) SF derived below where C=0.897(C(S)) and C(s)=concentration of urea in serum. There was an excellent correlation (r(2)=0.8588) between SF and serum urea in the direct aspirates with a ratio of 0.897 (SF/serum). Neither urea levels nor the SF/serum ratio showed any correlation with Kellgren Lawrence (KL) grade, or cell count. While urea levels increased with age there was no change in the ratio. Intraarticular SF volumes calculated for the lavaged knees ranged from 0.555 to 71.71ml with a median volume of 3.048ml. There was no correlation of SF volume to KL grade but there was a positive correlation (P=0.001) between SF volume and self-reported individual knee pain. Our urea results for direct aspirates indicate an equilibrium state between serum and SF with regard to the water fraction. This equilibrium exists regardless of disease status (KL grade), inflammation (cell count), or age, making it possible to calculate intraarticular volume of lavaged joints based upon this urea method. Most of the joint volumes we calculated fell within the previously reported range for normal knees of 0.5-4.0ml

  8. 2π proportional counting chamber for large-area-coated β sources

    Indian Academy of Sciences (India)

    Home; Journals; Pramana – Journal of Physics; Volume 86; Issue 6. 2 π proportional counting chamber for large-area-coated β sources ... A provision is made for change ofthe source and immediate measurement of source activity. These sources are used to calibrate the efficiency of contamination monitors at radiological ...

  9. Left ventricular ejection fraction and volumes as measured by 3D echocardiography and ultrafast computed tomography

    International Nuclear Information System (INIS)

    Vieira, Marcelo Luiz Campos; Nomura, Cesar H.; Tranchesi Junior, Bernardino; Oliveira, Wercules A. de; Naccarato, Gustavo; Serpa, Bruna S.; Passos, Rodrigo B.D.; Funari, Marcelo B. G.; Fischer, Claudio H.; Morhy, Samira S.

    2009-01-01

    Background: Real-time three-dimensional echocardiography (RT-3D-Echo) and ultrafast computed tomography (CT) are two novel methods for the analysis of LV ejection fraction and volumes. Objective: To compare LVEF and volume measurements as obtained using RT-3D-Echo and ultrafast CT. Methods: Thirty nine consecutive patients (27 men, mean age of 57+- 12 years) were studied using RT-3D-Echo and 64-slice ultrafast CT. LVEF and LV volumes were analyzed. Statistical analysis: coefficient of correlation (r: Pearson), Bland-Altman analysis, linear regression analysis, 95% CI, p 5 .58)%; end-diastolic volume ranged from 49.6 to 178.2 (87+-27.8) ml; end-systolic volume ranged from 11.4 to 78 (33.1+-13.6) ml. CT scan measurements: LVEF ranged from 53 to 86% (67.8+-7.78); end-diastolic volume ranged from 51 to 186 (106.5+-30.3) ml; end-systolic volume ranged from 7 to 72 (35.5+-13.4)ml. Correlations between RT-3D-Echo and CT were: LVEF (r: 0.7888, p<0.0001, 95% CI 0.6301 to 0.8843); end-diastolic volume (r: 0.7695, p<0.0001, 95% CI 0.5995 to 0.8730); end-systolic volume (r: 0.8119, p<0.0001, 95% CI 0.6673 to 0.8975). Conclusion: Good correlation between LVEF and ventricular volume parameters as measured by RT-3D-Echo and 64-slice ultrafast CT was found in the present case series. (author)

  10. Reliability and Accuracy of Brain Volume Measurement on MR Imaging

    DEFF Research Database (Denmark)

    Yamagchii, Kechiro; Lassen, Anders; Ring, Poul

    1998-01-01

    Yamaguchi, K., Lassen, A. And Ring, P. Reliability and Accuracy of Brain Volume Measurement on MR Imaging. Abstract at ESMRMB98 European Society for Magnetic Resonance in Medicine and Biology, Geneva, Sept 17-20, 1998 Danish Research Center for Magnetic Resonance, Hvidovre University Hospital...

  11. Variation in Measurements of Transtibial Stump Model Volume A Comparison of Five Methods

    NARCIS (Netherlands)

    Bolt, A.; de Boer-Wilzing, V. G.; Geertzen, J. H. B.; Emmelot, C. H.; Baars, E. C. T.; Dijkstra, P. U.

    Objective: To determine the right moment for fitting the first prosthesis, it is necessary to know when the volume of the stump has stabilized. The aim of this study is to analyze variation in measurements of transtibial stump model volumes using the water immersion method, the Design TT system, the

  12. Feasibility of the left ventricular volume measurement by acoustic quantification method. Comparison with ultrafast computed tomography

    International Nuclear Information System (INIS)

    Tomimoto, Shigehiro; Nakatani, Satoshi; Tanaka, Norio; Uematsu, Masaaki; Beppu, Shintaro; Nagata, Seiki; Hamada, Seiki; Takamiya, Makoto; Miyatake, Kunio

    1995-01-01

    Acoustic quantification (AQ: the real-time automated boundary detection system) allows instantaneous measurement of cardiac chamber volumes. The feasibility of this method was evaluated by comparing the left ventricular (LV) volumes obtained with AQ to those derived from ultrafast computed tomography (UFCT), which enables accurate measurements of LV volumes even in the presence of LV asynergy, in 23 patients (8 with ischemic heart disease, 5 with cardiomyopathy, 3 with valvular heart disease). Both LV end-diastolic and end-systolic volumes obtained with the AQ method were in good agreement with those obtained with UFCT (y=1.04χ-16.9, r=0.95; y=0.87χ+15.7, r=0.91; respectively). AQ was reliable even in the presence of LV asynergy. Interobserver variability for the AQ measurement was 10.2%. AQ provides a new, clinically useful method for real-time accurate estimation of the left ventricular volume. (author)

  13. Feasibility of the left ventricular volume measurement by acoustic quantification method. Comparison with ultrafast computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Tomimoto, Shigehiro; Nakatani, Satoshi; Tanaka, Norio; Uematsu, Masaaki; Beppu, Shintaro; Nagata, Seiki; Hamada, Seiki; Takamiya, Makoto; Miyatake, Kunio [National Cardiovascular Center, Suita, Osaka (Japan)

    1995-01-01

    Acoustic quantification (AQ: the real-time automated boundary detection system) allows instantaneous measurement of cardiac chamber volumes. The feasibility of this method was evaluated by comparing the left ventricular (LV) volumes obtained with AQ to those derived from ultrafast computed tomography (UFCT), which enables accurate measurements of LV volumes even in the presence of LV asynergy, in 23 patients (8 with ischemic heart disease, 5 with cardiomyopathy, 3 with valvular heart disease). Both LV end-diastolic and end-systolic volumes obtained with the AQ method were in good agreement with those obtained with UFCT (y=1.04{chi}-16.9, r=0.95; y=0.87{chi}+15.7, r=0.91; respectively). AQ was reliable even in the presence of LV asynergy. Interobserver variability for the AQ measurement was 10.2%. AQ provides a new, clinically useful method for real-time accurate estimation of the left ventricular volume. (author).

  14. Finite volume schemes with equilibrium type discretization of source terms for scalar conservation laws

    International Nuclear Information System (INIS)

    Botchorishvili, Ramaz; Pironneau, Olivier

    2003-01-01

    We develop here a new class of finite volume schemes on unstructured meshes for scalar conservation laws with stiff source terms. The schemes are of equilibrium type, hence with uniform bounds on approximate solutions, valid in cell entropy inequalities and exact for some equilibrium states. Convergence is investigated in the framework of kinetic schemes. Numerical tests show high computational efficiency and a significant advantage over standard cell centered discretization of source terms. Equilibrium type schemes produce accurate results even on test problems for which the standard approach fails. For some numerical tests they exhibit exponential type convergence rate. In two of our numerical tests an equilibrium type scheme with 441 nodes on a triangular mesh is more accurate than a standard scheme with 5000 2 grid points

  15. Situational awareness of hazards: Validation of multi-source radiation measurements

    Science.gov (United States)

    Hultquist, C.; Cervone, G.

    2016-12-01

    Citizen-led movements producing scientific hazard data during disasters are increasingly common. After the Japanese earthquake-triggered tsunami in 2011, and the resulting radioactive releases at the damaged Fukushima Daiichi nuclear power plants, citizens monitored on-ground levels of radiation with innovative mobile devices built from off-the-shelf components. To date, the citizen-led SAFECAST project has recorded 50 million radiation measurements worldwide, with the majority of these measurements from Japan. The analysis of data which are multi-dimensional, not vetted, and provided from multiple devices presents big data challenges due to their volume, velocity, variety, and veracity. While the SAFECAST project produced massive open-source radiation measurements at specific coordinates and times, the reliability and validity of the overall data have not yet been assessed. The nuclear disaster provides a case for assessing the SAFECAST data with official aerial remote sensing radiation data jointly collected by the governments of the United States and Japan. A spatial and statistical assessment of SAFECAST requires several preprocessing steps. First, SAFECAST ionized radiation sensors collected data using different units of measure than the government data, and they had to be converted. Secondly, the normally occurring radiation and decay rates of Cesium from deposition surveys were used to properly compare measurements in space and time. Finally, the GPS located points were selected within overlapping extents at multiple spatial resolutions. Quantitative measures were used to assess the similarity and differences in the observed measurements. Radiation measurements from the same geographic extents show similar spatial variations and statistically significant correlations. The results suggest that actionable scientific data for disasters and emergencies can be inferred from non-traditional and not vetted data generated through citizen science projects. This

  16. MRI-Based Measurement of Hippocampal Volume in Patients With Combat-Related Posttraumatic Stress Disorder

    Science.gov (United States)

    Bremner, J. Douglas; Randall, Penny; Scott, Tammy M.; Bronen, Richard A.; Seibyl, John P.; Southwick, Steven M.; Delaney, Richard C.; McCarthy, Gregory; Charney, Dennis S.; Innis, Robert B.

    2011-01-01

    Objective Studies in nonhuman primates suggest that high levels of cortisol associated with stress have neurotoxic effects on the hippocampus, a brain structure involved in memory. The authors previously showed that patients with combat-related posttraumatic stress disorder (PTSD) had deficits in short-term memory. The purpose of this study was to compare the hippocampal volume of patients with PTSD to that of subjects without psychiatric disorder. Method Magnetic resonance imaging was used to measure the volume of the hippocampus in 26 Vietnam combat veterans with PTSD and 22 comparison subjects selected to be similar to the patients in age, sex, race, years of education, socioeconomic status, body size, and years of alcohol abuse. Results The PTSD patients had a statistically significant 8% smaller right hippocampal volume relative to that of the comparison subjects, but there was no difference in the volume of other brain regions (caudate and temporal lobe). Deficits in short-term verbal memory as measured with the Wechsler Memory Scale were associated with smaller right hippocampal volume in the PTSD patients only. Conclusions These findings are consistent with a smaller right hippocampal volume in PTSD that is associated with functional deficits in verbal memory. PMID:7793467

  17. Source term determination from subcritical multiplication measurements at Koral-1 reactor

    International Nuclear Information System (INIS)

    Blazquez, J.B.; Barrado, J.M.

    1978-01-01

    By using an AmBe neutron source two independent procedures have been settled for the zero-power experimental fast-reactor Coral-1 in order to measure the source term which appears in the point kinetical equations. In the first one, the source term is measured when the reactor is just critical with source by taking advantage of the wide range of the linear approach to critical for Coral-1. In the second one, the measurement is made in subcritical state by making use of the previous calibrated control rods. Several applications are also included such as the measurement of the detector dead time, the determinations of the reactivity of small samples and the shape of the neutron importance of the source. (author)

  18. Modelling lidar volume-averaging and its significance to wind turbine wake measurements

    Science.gov (United States)

    Meyer Forsting, A. R.; Troldborg, N.; Borraccino, A.

    2017-05-01

    Lidar velocity measurements need to be interpreted differently than conventional in-situ readings. A commonly ignored factor is “volume-averaging”, which refers to lidars not sampling in a single, distinct point but along its entire beam length. However, especially in regions with large velocity gradients, like the rotor wake, can it be detrimental. Hence, an efficient algorithm mimicking lidar flow sampling is presented, which considers both pulsed and continous-wave lidar weighting functions. The flow-field around a 2.3 MW turbine is simulated using Detached Eddy Simulation in combination with an actuator line to test the algorithm and investigate the potential impact of volume-averaging. Even with very few points discretising the lidar beam is volume-averaging captured accurately. The difference in a lidar compared to a point measurement is greatest at the wake edges and increases from 30% one rotor diameter (D) downstream of the rotor to 60% at 3D.

  19. Volume conduction effects on wavelet cross-bicoherence analysis

    International Nuclear Information System (INIS)

    Memon, I.A.; Channa, C.

    2013-01-01

    Cross-bicoherence analysis is one of the important nonlinear signal processing tools which is used to measure quadratic phase coupling between frequencies of two different time series. It is frequently used in the diagnosis of various cognitive and neurological disorders in EEG (Electroencephalography) analysis. Volume conduction effects of various uncorrelated sources present in the brain can produce biased estimates into the estimated values of cross-bicoherence function. Previous studies have discussed volume conduction effects on coherence function which is used to measure linear relationship between EEG signals in terms of their phase and amplitude. However, volume conduction effect on cross-bicoherence analysis which is quite a different technique has not been investigated up to now to the best of our knowledge. This study is divided into two major parts, the first part deals with the investigation of VCUS (Volume Conduction effects due to Uncorrelated Sources) characteristics on EEG-cross-bicoherence analysis. The simulated EEG data due to uncorrelated sources present in the brain was used in this part of study. The next part of study is based upon investigating the effects of VCUS on the statistical analysis of results of EEG-based cross-bicoherence analysis. The study provides an important clinical application because most of studies based on EEG cross-bicoherence analysis have avoided the issue of VCUS. The cross-bicoherence analysis was performed by detecting the change in MSCB (Magnitude Square Cross-Bicoherence Function) between EEG activities of change detection and no-change detection trials. The real EEG signals were used. (author)

  20. Effects of Measurement Errors on Individual Tree Stem Volume Estimates for the Austrian National Forest Inventory

    Science.gov (United States)

    Ambros Berger; Thomas Gschwantner; Ronald E. McRoberts; Klemens. Schadauer

    2014-01-01

    National forest inventories typically estimate individual tree volumes using models that rely on measurements of predictor variables such as tree height and diameter, both of which are subject to measurement error. The aim of this study was to quantify the impacts of these measurement errors on the uncertainty of the model-based tree stem volume estimates. The impacts...

  1. Novel gravimetric measurement technique for quantitative volume calibration in the sub-microliter range

    International Nuclear Information System (INIS)

    Liang, Dong; Zengerle, Roland; Steinert, Chris; Ernst, Andreas; Koltay, Peter; Bammesberger, Stefan; Tanguy, Laurent

    2013-01-01

    We present a novel measurement method based on the gravimetric principles adapted from the ASTM E542 and ISO 4787 standards for quantitative volume determination in the sub-microliter range. Such a method is particularly important for the calibration of non-contact micro dispensers as well as other microfluidic devices. The novel method is based on the linear regression analysis of continuously monitored gravimetric results and therefore is referred to as ‘gravimetric regression method (GRM)’. In this context, the regression analysis is necessary to compensate the mass loss due to evaporation that is significant for very small dispensing volumes. A full assessment of the measurement uncertainty of GRM is presented and results in a standard measurement uncertainty around 6 nl for dosage volumes in the range from 40 nl to 1 µl. The GRM has been experimentally benchmarked with a dual-dye ratiometric photometric method (Artel Inc., Westbrook, ME, USA), which can provide traceability of measurement to the International System of Units (SI) through reference standards maintained by NIST. Good precision (max. CV = 2.8%) and consistency (bias around 7 nl in the volume range from 40 to 400 nl) have been observed comparing the two methods. Based on the ASTM and ISO standards on the one hand and the benchmark with the photometric method on the other hand, two different approaches for establishing traceability for the GRM are discussed. (paper)

  2. Contrast volume reduction using third generation dual source computed tomography for the evaluation of patients prior to transcatheter aortic valve implantation

    Energy Technology Data Exchange (ETDEWEB)

    Bittner, Daniel O. [University Hospital Erlangen, Friedrich-Alexander University Erlangen-Nuernberg (FAU), Department of Internal Medicine 2 (Cardiology), Erlangen (Germany); Harvard Medical School, Cardiac MR PET CT Program, Massachusetts General Hospital, Boston, MA (United States); Arnold, Martin; Klinghammer, Lutz; Schuhbaeck, Annika; Hell, Michaela M.; Muschiol, Gerd; Gauss, Soeren; Achenbach, Stephan; Marwan, Mohamed [University Hospital Erlangen, Friedrich-Alexander University Erlangen-Nuernberg (FAU), Department of Internal Medicine 2 (Cardiology), Erlangen (Germany); Lell, Michael; Uder, Michael [University Hospital Erlangen, Friedrich-Alexander University Erlangen-Nuernberg (FAU), Department of Radiology, Erlangen (Germany); Hoffmann, Udo [Harvard Medical School, Cardiac MR PET CT Program, Massachusetts General Hospital, Boston, MA (United States)

    2016-12-15

    Chronic renal failure is common in patients referred for transcatheter aortic valve implantation (TAVI). CT angiography is recommended and provides crucial information prior to TAVI. We evaluated the feasibility of a reduced contrast volume protocol for pre-procedural CT imaging. Forty consecutive patients were examined with prospectively ECG-triggered high-pitch spiral acquisition using a novel third-generation dual-source CT system; 38 ml contrast agent was used. Image quality was graded on a visual scale (1-4). Contrast attenuation was measured at the level of the aortic root and at the iliac bifurcation. Mean patient age was 82 ± 6 years (23 males; 58 %). Mean attenuation/average image quality was 285 ± 60 HU/1.5 at the aortic annulus compared to 289 ± 74 HU/1.8 at the iliac bifurcation (p = 0.77/p = 0.29). Mean estimated effective radiation dose was 2.9 ± 0.3 mSv. A repeat acquisition was necessary in one patient due to image quality. Out of the 35 patients who underwent TAVI, 31 (89 %) patients had no or mild aortic regurgitation. Thirty-two (91 %) patients were discharged successfully. Pre-procedural CTA with a total of 38 ml contrast volume is feasible and clinically useful, using third-generation dual-source CT, allowing comprehensive imaging for procedural success. (orig.)

  3. Measurements on low level plutonium sources using Rad Elec Electret Ion Chambers

    International Nuclear Information System (INIS)

    Levinskas, D.; Teagarden, J.; Wilkes, E.

    1998-01-01

    This is a technique for measuring gross alpha particle emission from interior contaminated surfaces. The technique utilizes electret ionization chambers (EICs), which consist of a charged Teflon plate (the electret) and an electrically-conductive plastic chamber of 145 ml volume. To measure very low levels of alpha contamination, the EIC is left in place on the surface to be measured for about 48 hours. The change in the surface charge of the electret is a measure of the ionization during the measurement period. The rate of change of the charge is converted into an activity using an appropriate calibration factor. This system has the ability to make accurate gross alpha contamination measurements while being subject to a high airborne radon concentration, such as might occur in certain buildings or during an atmospheric inversion. Previous studies of the effectiveness of these EIC's focused on levels of alpha contamination much higher than is allowed for unrestricted release of material at the Rocky Flats Environmental Technology Site (RFETS). This study evaluated the performance of EIC's at levels from 100 disintegrations per minute (dpm) per 100 cm 2 to below 20 dpm per 100 cm 2 (all measurements are referenced to a 4π geometry). The EIC's were found to be within 5% accuracy, as compared to a gas flow proportional counter calibrated with a NIST-traceable source. Test results indicate that the EIC, left in place for 48 hours, can detect alpha contamination as low as 6.4 ± 3.0 dpm/100 cm 2 to a 95% confidence level

  4. Automated cross-sectional and longitudinal hippocampal volume measurement in mild cognitive impairment and Alzheimer's disease.

    Science.gov (United States)

    Leung, Kelvin K; Barnes, Josephine; Ridgway, Gerard R; Bartlett, Jonathan W; Clarkson, Matthew J; Macdonald, Kate; Schuff, Norbert; Fox, Nick C; Ourselin, Sebastien

    2010-07-15

    Volume and change in volume of the hippocampus are both important markers of Alzheimer's disease (AD). Delineation of the structure on MRI is time-consuming and therefore reliable automated methods are required. We describe an improvement (multiple-atlas propagation and segmentation (MAPS)) to our template library-based segmentation technique. The improved technique uses non-linear registration of the best-matched templates from our manually segmented library to generate multiple segmentations and combines them using the simultaneous truth and performance level estimation (STAPLE) algorithm. Change in volume over 12months (MAPS-HBSI) was measured by applying the boundary shift integral using MAPS regions. Methods were developed and validated against manual measures using subsets from Alzheimer's Disease Neuroimaging Initiative (ADNI). The best method was applied to 682 ADNI subjects, at baseline and 12-month follow-up, enabling assessment of volumes and atrophy rates in control, mild cognitive impairment (MCI) and AD groups, and within MCI subgroups classified by subsequent clinical outcome. We compared our measures with those generated by Surgical Navigation Technologies (SNT) available from ADNI. The accuracy of our volumes was one of the highest reported (mean(SD) Jaccard Index 0.80(0.04) (N=30)). Both MAPS baseline volume and MAPS-HBSI atrophy rate distinguished between control, MCI and AD groups. Comparing MCI subgroups (reverters, stable and converters): volumes were lower and rates higher in converters compared with stable and reverter groups (pmethods give accurate and reliable volumes and atrophy rates across the clinical spectrum from healthy aging to AD. Copyright 2010 Elsevier Inc. All rights reserved.

  5. Airborne measurements of aerosol optical properties related to early spring transport of mid-latitude sources into the Arctic

    Directory of Open Access Journals (Sweden)

    R. A. de Villiers

    2010-06-01

    Full Text Available Airborne lidar and in-situ measurements of the aerosol properties were conducted between Svalbard Island and Scandinavia in April 2008. Evidence of aerosol transport from Europe and Asia is given. The analysis of the aerosol optical properties based on a multiwavelength lidar (355, 532, 1064 nm including volume depolarization at 355 nm aims at distinguishing the role of the different aerosol sources (Siberian wild fires, Eastern Asia and European anthropogenic emissions. Combining, first aircraft measurements, second FLEXPART simulations with a calculation of the PBL air fraction originating from the three different mid-latitude source regions, and third level-2 CALIPSO data products (i.e. backscatter coefficient 532 nm,volume depolarization and color ratio between 1064 and 532 nm in aerosol layers along the transport pathways, appears a valuable approach to identify the role of the different aerosol sources even after a transport time larger than 4 days. Optical depth of the aerosol layers are always rather small (<4% while transported over the Arctic and ratio of the total attenuated backscatter (i.e. including molecular contribution provide more stable result than conventional aerosol backscatter ratio. Above Asia, CALIPSO data indicate more depolarization (up to 15% and largest color ratio (>0.5 for the northeastern Asia emissions (i.e. an expected mixture of Asian pollution and dust, while low depolarization together with smaller and quasi constant color ratio (≈0.3 are observed for the Siberian biomass burning emissions. A similar difference is visible between two layers observed by the aircraft above Scandinavia. The analysis of the time evolution of the aerosol optical properties revealed by CALIPSO between Asia and Scandinavia shows a gradual decrease of the aerosol backscatter, depolarization ratio and color ratio which suggests the removal of the largest particles in the accumulation mode. A similar study conducted for a European

  6. MRI markers for mild cognitive impairment: comparisons between white matter integrity and gray matter volume measurements.

    Directory of Open Access Journals (Sweden)

    Yu Zhang

    Full Text Available The aim of the study was to evaluate the value of assessing white matter integrity using diffusion tensor imaging (DTI for classification of mild cognitive impairment (MCI and prediction of cognitive impairments in comparison to brain atrophy measurements using structural MRI. Fifty-one patients with MCI and 66 cognitive normal controls (CN underwent DTI and T1-weighted structural MRI. DTI measures included fractional anisotropy (FA and radial diffusivity (DR from 20 predetermined regions-of-interest (ROIs in the commissural, limbic and association tracts, which are thought to be involved in Alzheimer's disease; measures of regional gray matter (GM volume included 21 ROIs in medial temporal lobe, parietal cortex, and subcortical regions. Significant group differences between MCI and CN were detected by each MRI modality: In particular, reduced FA was found in splenium, left isthmus cingulum and fornix; increased DR was found in splenium, left isthmus cingulum and bilateral uncinate fasciculi; reduced GM volume was found in bilateral hippocampi, left entorhinal cortex, right amygdala and bilateral thalamus; and thinner cortex was found in the left entorhinal cortex. Group classifications based on FA or DR was significant and better than classifications based on GM volume. Using either DR or FA together with GM volume improved classification accuracy. Furthermore, all three measures, FA, DR and GM volume were similarly accurate in predicting cognitive performance in MCI patients. Taken together, the results imply that DTI measures are as accurate as measures of GM volume in detecting brain alterations that are associated with cognitive impairment. Furthermore, a combination of DTI and structural MRI measurements improves classification accuracy.

  7. Three-dimensional reconstruction volume: a novel method for volume measurement in kidney cancer.

    Science.gov (United States)

    Durso, Timothy A; Carnell, Jonathan; Turk, Thomas T; Gupta, Gopal N

    2014-06-01

    The role of volumetric estimation is becoming increasingly important in the staging, management, and prognostication of benign and cancerous conditions of the kidney. We evaluated the use of three-dimensional reconstruction volume (3DV) in determining renal parenchymal volumes (RPV) and renal tumor volumes (RTV). We compared 3DV with the currently available methods of volume assessment and determined its interuser reliability. RPV and RTV were assessed in 28 patients who underwent robot-assisted laparoscopic partial nephrectomy for kidney cancer. Patients with a preoperative creatinine level of kidney pre- and postsurgery overestimated 3D reconstruction volumes by 15% to 102% and 12% to 101%, respectively. In addition, volumes obtained from 3DV displayed high interuser reliability regardless of experience. 3DV provides a highly reliable way of assessing kidney volumes. Given that 3DV takes into account visible anatomy, the differences observed using previously published methods can be attributed to the failure of geometry to accurately approximate kidney or tumor shape. 3DV provides a more accurate, reproducible, and clinically useful tool for urologists looking to improve patient care using analysis related to volume.

  8. Intense Pulsed Neutron Source: Progress report 1991--1996. 15. Anniversary edition -- Volume 2

    International Nuclear Information System (INIS)

    1996-01-01

    The 15th Anniversary Edition of the IPNS Progress Report is being published in recognition of the Intense Pulsed Neutron Source's first 15 years of successful operation as a user facility. To emphasize the importance of this milestone, the author shave made the design and organization of the report significantly different from previous IPNS Progress Reports. This report consists of two volumes. For Volume 1, authors were asked to prepare articles that highlighted recent scientific accomplishments at IPNS, from 1991 to present; to focus on and illustrate the scientific advances achieved through the unique capabilities of neutron studies performed by IPNS users; to report on specific activities or results from an instrument; or to focus on a body of work encompassing different neutron-scattering techniques. Articles were also included on the accelerator system, instrumentation, computing, target, and moderators. A list of published and ''in press' articles in journals, books, and conference proceedings, resulting from work done at IPNS since 1991, was compiled. This list is arranged alphabetically according to first author. Publication references in the articles are listed by last name of first author and year of publication. The IPNS experimental reports received since 1991 are compiled in Volume 2. Experimental reports referenced in the articles are listed by last name of first author, instrument designation, and experiment number

  9. Intense Pulsed Neutron Source: Progress report 1991--1996. 15. Anniversary edition -- Volume 1

    International Nuclear Information System (INIS)

    Marzec, B.

    1996-01-01

    The 15th Anniversary Edition of the IPNS Progress Report is being published in recognition of the Intense Pulsed Neutron Source's first 15 years of successful operation as a user facility. To emphasize the importance of this milestone, the authors have made the design and organization of the report significantly different from previous IPNS Progress Reports. This report consists of two volumes. For Volume 1, authors were asked to prepare articles that highlighted recent scientific accomplishments at IPNS, from 1991 to present; to focus on and illustrate the scientific advances achieved through the unique capabilities of neutron studies performed by IPNS users; to report on specific activities or results from an instrument; or to focus on a body of work encompassing different neutron-scattering techniques. Articles were also included on the accelerator system, instrumentation, computing, target, and moderators. A list of published and ''in press' articles in journals, books, and conference proceedings, resulting from work done at IPNS since 1991, was compiled. This list is arranged alphabetically according to first author. Publication references in the articles are listed by last name of first author and year of publication. The IPNS experimental reports received since 1991 are compiled in Volume 2. Experimental reports referenced in the articles are listed by last name of first author, instrument designation, and experiment number

  10. Generator localization by current source density (CSD): Implications of volume conduction and field closure at intracranial and scalp resolutions

    Science.gov (United States)

    Tenke, Craig E.; Kayser, Jürgen

    2012-01-01

    The topographic ambiguity and reference-dependency that has plagued EEG/ERP research throughout its history are largely attributable to volume conduction, which may be concisely described by a vector form of Ohm’s Law. This biophysical relationship is common to popular algorithms that infer neuronal generators via inverse solutions. It may be further simplified as Poisson’s source equation, which identifies underlying current generators from estimates of the second spatial derivative of the field potential (Laplacian transformation). Intracranial current source density (CSD) studies have dissected the “cortical dipole” into intracortical sources and sinks, corresponding to physiologically-meaningful patterns of neuronal activity at a sublaminar resolution, much of which is locally cancelled (i.e., closed field). By virtue of the macroscopic scale of the scalp-recorded EEG, a surface Laplacian reflects the radial projections of these underlying currents, representing a unique, unambiguous measure of neuronal activity at scalp. Although the surface Laplacian requires minimal assumptions compared to complex, model-sensitive inverses, the resulting waveform topographies faithfully summarize and simplify essential constraints that must be placed on putative generators of a scalp potential topography, even if they arise from deep or partially-closed fields. CSD methods thereby provide a global empirical and biophysical context for generator localization, spanning scales from intracortical to scalp recordings. PMID:22796039

  11. Self-weight effect in the measurement of the volume of silicon spheres

    Science.gov (United States)

    Mari, D.; Massa, E.; Kuramoto, N.; Mana, G.

    2018-04-01

    The volume of 28Si spheres about 94 mm in diameter is an input datum for the determination of the Avogadro constant. We report a finite element analysis of the self-weight effect on the volume determination via optical interferometric measurements of the sphere diameters. The self-weight expansion or shrinkage of the equatorial diameters, which ranges from  -31 pm to  +180 pm, depends on the southern latitude of the supports.

  12. Measurement of normal ocular volume by the use of computed ...

    African Journals Online (AJOL)

    2012-09-03

    Sep 3, 2012 ... ocular axial length measurements from which ocular volume can be calculated. ... The CT scans were performed in axial planes at a thickness of 3 mm and a .... dimension assessing capability, it gives anatomic details .... have larger skeletal size and bone mass than females, despite comparable body size.

  13. Near-infrared spectroscopy measurement of the pulsatile component of cerebral blood flow and volume from arterial oscillations

    Science.gov (United States)

    Themelis, George; D'Arceuil, Helen; Diamond, Solomon G.; Thaker, Sonal; Huppert, Theodore J.; Boas, David A.

    2009-01-01

    We describe a near-infrared spectroscopy (NIRS) method to noninvasively measure relative changes in the pulsate components of cerebral blood flow (pCBF) and volume (pCBV) from the shape of heartbeat oscillations. We present a model that is used and data to show the feasibility of the method. We use a continuous-wave NIRS system to measure the arterial oscillations originating in the brains of piglets. Changes in the animals' CBF are induced by adding CO2 to the breathing gas. To study the influence of scalp on our measurements, comparative, invasive measurements are performed on one side of the head simultaneously with noninvasive measurements on the other side. We also did comparative measurements of CBF using a laser Doppler system to validate the results of our method. The results indicate that for sufficient source-detector separation, the signal contribution of the scalp is minimal and the measurements are representative of the cerebral hemodynamics. Moreover, good correlation between the results of the laser Doppler system and the NIRS system indicate that the presented method is capable of measuring relative changes in CBF. Preliminary results show the potential of this NIRS method to measure pCBF and pCBV relative changes in neonatal pigs. PMID:17343508

  14. MR measurement of the basal ganglia volume in the tourette syndrome

    International Nuclear Information System (INIS)

    Liao Kaibing; Li Guiping; Yang Bo; Feng Gansheng

    2014-01-01

    Objective: To compare the volume of the basal ganglia in patients with Tourette syndrome (TS) and the normal volunteers and to explore the underlying anatomical basis of TS. Methods: Thirty-one cases of TS (TS subjects), 31 gender and age-matched subjects (the control subjects) were examined on a 3.0 T MRI system. The volume of the caudate nucleus, globus pallidus, putamen of the two sides and the brain volume were measured with volume analysis software, and the data were normalized according to the individual brain volume. Statistical analysis was performed using t test to compare between the TS subjects and the controls. Results: The volume of the both sides of the caudate nucleus, putamen and globus pallidus of TS subjects were (4.11 ±0.12) and (3.76 ±0.11), (2.28 ±0.12) and (2.35 ±0.28), (4.98 ±0.20) and (4.89 ±0.31) cm 3 , while they were (4.88 ±0.19) and (4.30 ±0.12), (2.28 ±0.12) and (2.35 ±0.28), (4.98 ±0.20) and (4.89 ±0.31) cm 3 in the controls, respectively. There were significant differences in the bilateral caudate nucleus and globus pallidus between the TS subjects and control subjects (t=2.97, 1.74, 3.72, 3.93, P<0.05), but there were no significant differences of the volume in the bilateral putamen between the TS and control subjects (t=0.47, 1.31, P>0.05). The volume was not significantly different between the left and right caudate nucleus in the TS subjects (t=1.81, P>0.05), but the left volume of the caudate nucleus was bigger in the control subjects compared with the right volume, however, there was significant difference between the bilateral caudate nucleus in the control subjects (t=2.34, P<0.05). There were no differences of volume between the bilateral globus pallidus and putamen in both the TS and control subjects (t=1.12, 1.44, 1.68, 0.38, P>0.05). Conclusion: The abnormal volume of caudate nucleus, putamen, and the globus pallidus may be involved in the pathogenesis of TS. (authors)

  15. Volume Recovery of Polymeric Glasses: Application of a Capacitance-based Measurement Technique

    Science.gov (United States)

    Sakib, Nazam; Simon, Sindee

    Glasses, including polymeric glasses, are inherently non-equilibrium materials. As a consequence, the volume and enthalpy of a glass evolve towards equilibrium in a process termed structural recovery. Several open questions and new controversies remain unanswered in the field. Specifically, the presence of intermediate plateaus during isothermal structural recovery has been reported in recent enthalpy work. In addition, the dependence of the relaxation time on state variables and thermal history is unclear. Dilatometry is particularly useful for structural recovery studies because volume is an absolute quantity and volumetric measurements can be done in-situ. A capillary dilatometer, fitted with a linear variable differential transducer, was used previously to measure volume recovery of polymeric glass formers in our laboratory. To improve on the limitations associated with that methodology, including competition between the range of measurements versus the sensitivity, a capacitance-based technique has been developed following the work of Richert, 2010. The modification is performed by converting the glass capillary dilatometer into a cylindrical capacitor. For precision in capacitance data acquisition, an Andeen-Hagerling ultra-precision capacitance bridge (2550A, 1 kHz) is used. The setup will be tested by performing the signatures of structural recovery as described by Kovacs, 1963. Experiments are also planned to address the open questions in the field.

  16. Perception and acceptance of technological risk sources. Volume 2. Empirical analysis of risk perception and acceptance

    Energy Technology Data Exchange (ETDEWEB)

    Renn, O

    1981-01-01

    Volume 2 presents a comparative investigation of risk perception and acceptance. It contains the evaluations of the two experiments in social psychology and the analysis of two intensive inquiries concerning risk perception with a view to 12 different risk sources. The data of the two inquiries were acquired from a total of 200 interview partners in two cities in North-Rhine Westphalia.

  17. Miniature electron bombardment evaporation source: evaporation rate measurement

    International Nuclear Information System (INIS)

    Nehasil, V.; Masek, K.; Matolin, V.; Moreau, O.

    1997-01-01

    Miniature electron beam evaporation sources which operate on the principle of vaporization of source material, in the form of a tip, by electron bombardment are produced by several companies specialized in UHV equipment. These sources are used primarily for materials that are normally difficult to deposit due to their high evaporation temperature. They are appropriate for special applications such as heteroepitaxial thin film growth requiring a very low and well controlled deposition rate. A simple and easily applicable method of evaporation rate control is proposed. The method is based on the measurement of ion current produced by electron bombardment of evaporated atoms. The absolute evaporation flux values were measured by means of the Bayard-Alpert ion gauge, which enabled the ion current vs evaporation flux calibration curves to be plotted. (author). 1 tab., 4 figs., 6 refs

  18. Mexico City air quality research initiative. Volume IV. Characterization and measurement

    Energy Technology Data Exchange (ETDEWEB)

    Mauzy, A. [ed.

    1994-04-01

    This volume describes the methods and the data gathered in an attempt to measure and characterize the meteorological factors and the concentration of different pollutants in the Mexico City Metropolitan Area. The main objective of this document was to provide input for the simulation models and to obtain information that could be used to test and improve the models` performance. Four field campaigns were conducted, as well as routine monitoring, in order to obtain a database of atmospheric dynamics and air pollution characteristics. Sections include Airborne measurements, Remote sensing measurements, and Traditional (in situ) measurements.

  19. Effect of malaria on placental volume measured using three-dimensional ultrasound: a pilot study

    Directory of Open Access Journals (Sweden)

    Rijken Marcus J

    2012-01-01

    Full Text Available Abstract Background The presence of malaria parasites and histopathological changes in the placenta are associated with a reduction in birth weight, principally due to intrauterine growth restriction. The aim of this study was to examine the feasibility of studying early pregnancy placental volumes using three-dimensional (3D ultrasound in a malaria endemic area, as a small volume in the second trimester may be an indicator of intra-uterine growth restriction and placental insufficiency. Methods Placenta volumes were acquired using a portable ultrasound machine and a 3D ultrasound transducer and estimated using the Virtual Organ Computer-aided AnaLysis (VOCAL image analysis software package. Intra-observer reliability and limits of agreement of the placenta volume measurements were calculated. Polynomial regression models for the mean and standard deviation as a function of gestational age for the placental volumes of uninfected women were created and tested. Based on these equations each measurement was converted into a z -score. The z-scores of the placental volumes of malaria infected and uninfected women were then compared. Results Eighty-four women (uninfected = 65; infected = 19 with a posterior placenta delivered congenitally normal, live born, single babies. The mean placental volumes in the uninfected women were modeled to fit 5th, 10th, 50th, 90th and 95th centiles for 14-24 weeks' gestation. Most placenta volumes in the infected women were below the 50th centile for gestational age; most of those with Plasmodium falciparum were below the 10th centile. The 95% intra-observer limits of agreement for first and second measurements were ± 37.0 mL and ± 25.4 mL at 30 degrees and 15 degrees rotation respectively. Conclusion The new technique of 3D ultrasound volumetry of the placenta may be useful to improve our understanding of the pathophysiological constraints on foetal growth caused by malaria infection in early pregnancy.

  20. Evaluation of Sources of Uncertainties in Solar Resource Measurement

    Energy Technology Data Exchange (ETDEWEB)

    Habte, Aron M [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Sengupta, Manajit [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2017-09-25

    This poster presents a high-level overview of sources of uncertainties in solar resource measurement, demonstrating the impact of various sources of uncertainties -- such as cosine response, thermal offset, spectral response, and others -- on the accuracy of data from several radiometers. The study provides insight on how to reduce the impact of some of the sources of uncertainties.

  1. Beam emittance measurements on multicusp ion sources

    Energy Technology Data Exchange (ETDEWEB)

    Sarstedt, M.; Lee, Y.; Leung, K.N. [and others

    1995-08-01

    Multicusp ion sources are used for various applications. Presently, the implementation of this type of ion source planned for the development of an ion beam lithography machine, which will be used for the projection of sub-0.2 {mu}m patterns onto a wafer substrate. Since, for this application, a very good beam quality and a small ion energy spread are required, emittance measurements have been performed on a multicusp ion source for various source conditions. It is shown that the installation of proper capacitors between the extraction electrodes is necessary to avoid rf-pickup, which otherwise leads to a distortion of the beam emittance. The influence of the magnetic filter field on the beam emittance has been investigated, and the beam emittance of a dc filament-discharge plasma has also been compared to that of an rf-generated plasma.

  2. Beam emittance measurements on multicusp ion sources

    International Nuclear Information System (INIS)

    Sarstedt, M.; Lee, Y.; Leung, K.N.

    1995-08-01

    Multicusp ion sources are used for various applications. Presently, the implementation of this type of ion source planned for the development of an ion beam lithography machine, which will be used for the projection of sub-0.2 μm patterns onto a wafer substrate. Since, for this application, a very good beam quality and a small ion energy spread are required, emittance measurements have been performed on a multicusp ion source for various source conditions. It is shown that the installation of proper capacitors between the extraction electrodes is necessary to avoid rf-pickup, which otherwise leads to a distortion of the beam emittance. The influence of the magnetic filter field on the beam emittance has been investigated, and the beam emittance of a dc filament-discharge plasma has also been compared to that of an rf-generated plasma

  3. Precision of gated equilibrium radioventriculography in measuring left ventricular stroke volume

    International Nuclear Information System (INIS)

    Bourguignon, M.H.; Wise, R.A.; Ehrlich, W.E.; Douglas, K.H.; Camargo, E.E.; Harrison, K.E.; Wagner, H.N. Jr.

    1983-01-01

    We have demonstrated that relative changes of small amplitude in ventricular stroke volume can be measured accurately in dogs when a fully automated technique for delineation of end diastolic and end systolic region of interest (ROI) is used. Consequently, we expect such a technique to be very sensitive in measuring relative changes of any ventricular quantitative parameter from gated equilibrium radio ventriculography in humans

  4. Measurement of radiation skyshine with D-T neutron source

    Energy Technology Data Exchange (ETDEWEB)

    Yoshida, S.; Nishitani, T. E-mail: nisitani@naka.jaeri.go.jp; Ochiai, K.; Kaneko, J.; Hori, J.; Sato, S.; Yamauchi, M.; Tanaka, R.; Nakao, M.; Wada, M.; Wakisaka, M.; Murata, I.; Kutsukake, C.; Tanaka, S.; Sawamura, T.; Takahashi, A

    2003-09-01

    The D-T neutron skyshine experiments have been carried out at the Fusion Neutronics Source (FNS) of JAERI with the neutron yield of {approx}1.7x10{sup 11} n/s. The concrete thickness of the roof and the wall of a FNS target room are 1.15 and 2 m, respectively. The FNS skyshine port with a size of 0.9x0.9 m{sup 2} was open during the experimental period. The radiation dose rate outside the target room was measured a maximum distance of 550 m from the D-T target point with a spherical rem-counter. Secondary gamma-rays were measured with high purity Ge detectors and NaI scintillation counters. The highest neutron dose was about 9x10{sup -22} Sv/(source neutron) at a distance of 30 m from the D-T target point and the dose rate was attenuated to 4x10{sup -24} Sv/(source neutron) at a distance of 550 m. The measured neutron dose distribution was analyzed with Monte Carlo code MCNP-4B and a simple line source model. The MCNP calculation overestimates the neutron dose in the distance range larger than 230 m. The line source model agrees well with the experimental results within the distance of 350 m.

  5. Measurement of cardiac ventricular volumes using multidetector row computed tomography: comparison of two- and three-dimensional methods

    International Nuclear Information System (INIS)

    Montaudon, M.; Laffon, E.; Berger, P.; Corneloup, O.; Latrabe, V.; Laurent, F.

    2006-01-01

    This study compared a three-dimensional volumetric threshold-based method to a two-dimensional Simpson's rule based short-axis multiplanar method for measuring right (RV) and left ventricular (LV) volumes, stroke volumes, and ejection fraction using electrocardiography-gated multidetector computed tomography (MDCT) data sets. End-diastolic volume (EDV) and end-systolic volume (ESV) of RV and LV were measured independently and blindly by two observers from contrast-enhanced MDCT images using commercial software in 18 patients. For RV and LV the three-dimensionally calculated EDV and ESV values were smaller than those provided by two-dimensional short axis (10%, 5%, 15% and 26% differences respectively). Agreement between the two methods was found for LV (EDV/ESV: r=0.974/0.910, ICC=0.905/0.890) but not for RV (r=0.882/0.930, ICC=0.663/0.544). Measurement errors were significant only for EDV of LV using the two-dimensional method. Similar reproducibility was found for LV measurements, but the three-dimensional method provided greater reproducibility for RV measurements than the two-dimensional. The threshold value supported three-dimensional method provides reproducible cardiac ventricular volume measurements, comparable to those obtained using the short-axis Simpson based method. (orig.)

  6. Volume comparison of radiofrequency ablation at 3- and 5-cm target volumes for four different radiofrequency generators: MR volumetry in an open 1-T MRI system versus macroscopic measurement.

    Science.gov (United States)

    Rathke, Hendrik; Hamm, Bernd; Guettler, Felix; Lohneis, Philipp; Stroux, Andrea; Suttmeyer, Britta; Jonczyk, Martin; Teichgräber, Ulf; de Bucourt, Maximilian

    2015-12-01

    In a patient, it is usually not macroscopically possible to estimate the non-viable volume induced by radiofrequency ablation (RFA) after the procedure. The purpose of this study was to use an ex vivo bovine liver model to perform magnetic resonance (MR) volumetry of the visible tissue signal change induced by RFA and to correlate the MR measurement with the actual macroscopic volume measured in the dissected specimens. Sixty-four liver specimens cut from 16 bovine livers were ablated under constant simulated, close physiological conditions with target volumes set to 14.14 ml (3-cm lesion) and 65.45 ml (5-cm lesion). Four commercially available radiofrequency (RF) systems were tested (n=16 for each system; n=8 for 3 cm and n=8 for 5 cm). A T1-weighted turbo spin echo (TSE) sequence with inversion recovery and a proton-density (PD)-weighted TSE sequence were acquired in a 1.0-T open magnetic resonance imaging (MRI) system. After manual dissection, actual macroscopic ablation diameters were measured and volumes calculated. MR volumetry was performed using a semiautomatic software tool. To validate the correctness and feasibility of the volume formula in macroscopic measurements, MR multiplanar reformation diameter measurements with subsequent volume calculation and semiautomatic MR volumes were correlated. Semiautomatic MR volumetry yielded smaller volumes than manual measurement after dissection, irrespective of RF system used, target lesion size, and MR sequence. For the 3-cm lesion, only 43.3% (T1) and 41.5% (PD) of the entire necrosis are detectable. For the 5-cm lesion, only 40.8% (T1) and 37.2% (PD) are visualized in MRI directly after intervention. The correlation between semiautomatic MR volumes and calculated MR volumes was 0.888 for the T1-weighted sequence and 0.875 for the PD sequence. After correlation of semiautomatic MR volumes and calculated MR volumes, it seems reasonable to use the respective volume formula for macroscopic volume calculation

  7. Knee effusion-synovitis volume measurement and effects of vitamin D supplementation in patients with knee osteoarthritis.

    Science.gov (United States)

    Wang, X; Cicuttini, F; Jin, X; Wluka, A E; Han, W; Zhu, Z; Blizzard, L; Antony, B; Winzenberg, T; Jones, G; Ding, C

    2017-08-01

    To develop a measure of knee joint effusion-synovitis volume and to examine the effect of vitamin D supplementation on effusion-synovitis in people with knee osteoarthritis (OA) and low vitamin D levels over 24 months. Symptomatic knee OA patients with low 25-(OH)D levels (12.5-60 nmol/l) were recruited for a multi-centre, randomised, placebo-controlled and double-blind trial. Participants (age 63 ± 7 years, 208 females) were allocated to either 50,000 IU monthly vitamin D 3 (n = 209) or placebo (n = 204) for 24 months. Knee effusion-synovitis volume in suprapatellar and other regions was measured on magnetic resonance imaging (MRI) using OsiriX software. The intra-class correlation coefficients (ICCs) were used to test inter- and intra-rater reliabilities. The least significant change criterion was used to define the increase/decrease in effusion-synovitis volume. The reproducibilities of effusion-synovitis volume measurement were high with ICCs ranging from 0.93 to 0.99. Over 24 months, effusion-synovitis volume remained stable in the vitamin D group but increased in placebos with a significant between-group difference (-1.94 ml, 95% confidence interval (CI): -3.54, -0.33). This effect was evident in those with baseline effusion-synovitis and with suprapatellar effusion-synovitis. The proportion with an increase in effusion-synovitis volume was lower in the vitamin D group than placebo (risk ratio (RR): 0.87, 95% CI: 0.77, 0.97). This highly reproducible effusion-synovitis volume measurement could be a promising outcome measure in OA trials. Vitamin D supplementation could retard the progression of effusion-synovitis which can potentially benefit people with an inflammatory OA phenotype. Copyright © 2017 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.

  8. Volume Measurements of Laser-generated Pits for In Situ Geochronology using KArLE (Potassium-Argon Laser Experiment)

    Science.gov (United States)

    French, R. A.; Cohen, B. A.; Miller, J. S.

    2014-01-01

    The Potassium-Argon Laser Experiment( KArLE), is composed of two main instruments: a spectrometer as part of the Laser-Induced Breakdown Spectroscopy (LIBS) method and a Mass Spectrometer (MS). The LIBS laser ablates a sample and creates a plasma cloud, generating a pit in the sample. The LIBS plasma is measured for K abundance in weight percent and the released gas is measured using the MS, which calculates Ar abundance in mols. To relate the K and Ar measurements, total mass of the ablated sample is needed but can be difficult to directly measure. Instead, density and volume are used to calculate mass, where density is calculated based on the elemental composition of the rock (from the emission spectrum) and volume is determined by pit morphology. This study aims to reduce the uncertainty for KArLE by analyzing pit volume relationships in several analog materials and comparing methods of pit volume measurements and their associated uncertainties.

  9. Validation of multi-detector computed tomography as a non-invasive method for measuring ovarian volume in macaques (Macaca fascicularis).

    Science.gov (United States)

    Jones, Jeryl C; Appt, Susan E; Werre, Stephen R; Tan, Joshua C; Kaplan, Jay R

    2010-06-01

    The purpose of this study was to validate low radiation dose, contrast-enhanced, multi-detector computed tomography (MDCT) as a non-invasive method for measuring ovarian volume in macaques. Computed tomography scans of four known-volume phantoms and nine mature female cynomolgus macaques were acquired using a previously described, low radiation dose scanning protocol, intravenous contrast enhancement, and a 32-slice MDCT scanner. Immediately following MDCT, ovaries were surgically removed and the ovarian weights were measured. The ovarian volumes were determined using water displacement. A veterinary radiologist who was unaware of actual volumes measured ovarian CT volumes three times, using a laptop computer, pen display tablet, hand-traced regions of interest, and free image analysis software. A statistician selected and performed all tests comparing the actual and CT data. Ovaries were successfully located in all MDCT scans. The iliac arteries and veins, uterus, fallopian tubes, cervix, ureters, urinary bladder, rectum, and colon were also consistently visualized. Large antral follicles were detected in six ovaries. Phantom mean CT volume was 0.702+/-SD 0.504 cc and the mean actual volume was 0.743+/-SD 0.526 cc. Ovary mean CT volume was 0.258+/-SD 0.159 cc and mean water displacement volume was 0.257+/-SD 0.145 cc. For phantoms, the mean coefficient of variation for CT volumes was 2.5%. For ovaries, the least squares mean coefficient of variation for CT volumes was 5.4%. The ovarian CT volume was significantly associated with actual ovarian volume (ICC coefficient 0.79, regression coefficient 0.5, P=0.0006) and the actual ovarian weight (ICC coefficient 0.62, regression coefficient 0.6, P=0.015). There was no association between the CT volume accuracy and mean ovarian CT density (degree of intravenous contrast enhancement), and there was no proportional or fixed bias in the CT volume measurements. Findings from this study indicate that MDCT is a valid non

  10. Inter-Scan Reproducibility of Carotid Plaque Volume Measurements by 3-D Ultrasound

    DEFF Research Database (Denmark)

    Sandholt, Benjamin V; Collet-Billon, Antoine; Entrekin, Robert

    2018-01-01

    (PPV) measure centered on MPT. Total plaque volume (TPV), PPV from a 10-mm segment and MPT were measured using dedicated semi-automated software on 38 plaques from 26 patients. Inter-scan reproducibility was assessed using the t-test, Bland-Altman plots and Pearson's correlation coefficient....... There was a mean difference of 0.01 mm in MPT (limits of agreement: -0.45 to 0.42 mm, Pearson's correlation coefficient: 0.96). Both volume measurements exhibited high reproducibility, with PPV being superior (limits of agreement: -35.3 mm3to 33.5 mm3, Pearson's correlation coefficient: 0.96) to TPV (limits...... of agreement: -88.2 to 61.5 mm3, Pearson's correlation coefficient: 0.91). The good reproducibility revealed by the present results encourages future studies on establishing plaque quantification as part of cardiovascular risk assessment and for follow-up of disease progression over time....

  11. Use of β-ray source for measurement of adsorption

    International Nuclear Information System (INIS)

    Kawakami, Hirokane; Nishimura, Keigo; Oshima, Takayoshi

    1987-01-01

    A research project has been carried out with the goal of determining the mass of a neutrino from β-decay measurements. During a study seeking the development of a β-ray source for this purpose, it was found that the amount of residual gas adsorbed on a cooled β-ray source can be measured successfully. Electrons emitted from a β-ray source is measured by an electron spectrometer. A sharp, nearly symmetric peak is obtained if all electrons have the same energy. If gas is adsorbed on the surface of the source, on the other hand, the resultant spectrum has a rather different profile due to energy loss caused by the gas. The difference between the energy loss spectrum and the original spectrum must be proportional to the amount of the adsorbed gas. In this study, a 109 Cd source with an electron energy peak at 18 keV is selected and the number of molecules adsorbed on the source, cooled to -35 deg C at 5 x 10 -7 Torr, is determined. Assuming that the gas is water vapor, it is shown that the adsorbed layer is of a two-molecular thickness on the average. It is also found that the thickness is reversible at varrying temperatures and does not change for two days. This gas amount is 7,500 time as large as that in the case of physical adsorption of water. (Nogami, K.)

  12. Limitations of intraoperative adrenal remnant volume measurement in patients undergoing subtotal adrenalectomy.

    Science.gov (United States)

    Brauckhoff, Michael; Stock, Karsten; Stock, Susanne; Lorenz, Kerstin; Sekulla, Carsten; Brauckhoff, Katrin; Thanh, Phuong Nguyen; Gimm, Oliver; Spielmann, Rolf Peter; Dralle, Henning

    2008-05-01

    Recent studies have shown that a minimum of approximately one-third of one normal adrenal gland is required for sufficient adrenocortical stress capacity. Correlation between intraoperative measurement, determination of remnant size by computed tomography (CT), and adrenocortical stress capacity has not been examined so far. Twenty-two patients with familial pheochromocytoma (n=13), sporadic pheochromocytoma (n=3), and adrenocortical tumors (n=6) who underwent unilateral or bilateral subtotal adrenalectomy (STAE, 28 adrenal remnants) were prospectively studied. Patients were examined in a multi-slice CT to determine residual adrenal tissue and by ACTH test 4 days and 3 months postoperatively. There was a slight significant correlation between intraoperative and CT calculated volumes (r=0.77; pSTAE has limitations. CT gives larger volumes compared with intraoperative determination. For calculation of a volume-function correlation of residual adrenal tissue, in clinical practice, the determination of relative adrenal residual volume is acceptable.

  13. The magnet measurement facility for the Advanced Photon Source

    International Nuclear Information System (INIS)

    Kim, S.H.; Doose, C.; Hogrefe, R.; Kim, K.; Merl, R.

    1993-01-01

    A magnet measurement facility has been developed to measure the prototype and production magnets for the Advance Photon Source. The measurement facility is semi-automatic in measurement control and data analysis. One dipole system and three rotating coil measurement systems for quadrupole and sextupole magnets and corresponding probe coils are described

  14. The OpenPMU Platform for Open Source Phasor Measurements

    OpenAIRE

    Laverty, David M.; Best, Robert J.; Brogan, Paul; Al-Khatib, Iyad; Vanfretti, Luigi; Morrow, D John

    2013-01-01

    OpenPMU is an open platform for the development of phasor measurement unit (PMU) technology. A need has been identified for an open-source alternative to commercial PMU devices tailored to the needs of the university researcher and for enabling the development of new synchrophasor instruments from this foundation. OpenPMU achieves this through open-source hardware design specifications and software source code, allowing duplicates of the OpenPMU to be fabricated under open-source licenses. Th...

  15. Direct Measurement of the Volume of Liquid Water Emitted During Eruptions of Lone Star Geyser, Yellowstone National Park, Wyoming

    Science.gov (United States)

    Murphy, F.; Hurwitz, S.; Johnston, M. J.; Vandemeulebrouck, J.; Pontbriand, C.; Sohn, R. A.; Karlstrom, L.; Rudolph, M. L.

    2011-12-01

    In September, 2010 a comprehensive series of instrumental observations was carried out at Lone Star Geyser in Yellowstone National Park to measure changes in the geyser and its surroundings during eruptions. That project included measurements of flow in the streams that drain the geyser area. Three small streams convey liquid water from the geyser and many of the surrounding hot springs to the Firehole River, about 75 m south of the geyser cone. We developed rating curves for two of these streams by measuring channel cross-sections and timing floating markers (using stopwatches and video recordings) while simultaneously recording stream depth at two-second intervals at two locations using pressure transducers and dataloggers. We estimated the flow in the third (ungaged) stream to be 0.15 of the flow in the easternmost stream, with which it shares a source area and part of its channel. The eruption cycle takes about 3 hours, and a total of nine eruption cycles were observed. During these 3-hour cycles the geyser and the nearby hot springs deliver a total of between 15 and 28 m3 of water to the Firehole River. During the 10-20 minutes of the main phase of an eruption, the geyser delivered between 8 and 11 m3 of water to the three streams. The volume of water emitted during eruptions appears to display a significant diurnal variation which strongly correlates with air temperature, with significantly more flow during early afternoon hours. There were also significant variations in the distribution of flow between the different channels. Our calculations suggest that losses due to evaporation along the flow channels are negligible, and losses due to infiltration appear to be small. The calculated volumes of water discharge do not account for the volume of erupted steam or evaporation of liquid water from the jet. Steam discharge will be assessed using image analysis of high speed video. The calculated volumes provide accurate and important constraint for models of

  16. Source apportionment of traffic emissions of particulate matter using tunnel measurements

    Science.gov (United States)

    Lawrence, Samantha; Sokhi, Ranjeet; Ravindra, Khaiwal; Mao, Hongjun; Prain, Hunter Douglas; Bull, Ian D.

    2013-10-01

    This study aims to quantify exhaust/non-exhaust emissions and the uncertainties associated with them by combining innovative motorway tunnel sampling and source apportionment modelling. Analytical techniques ICP-AES and GC-MS were used to identify the metallic and organic composition of PM10, respectively. Good correlation was observed between Fe, Cu, Mn, Ni, Pb and Sb and change in traffic volume. The concentration of polycyclic aromatic hydrocarbons and other organics varies significantly at the entrance and exit site of the tunnel, with fluoranthene, pyrene, benzo[a]pyrene, chrysene and benzothiazole having the highest incremented concentrations. The application of Principal Component Analysis and Multiple Linear Regression Analysis helped to identify the emission sources for 82% of the total PM10 mass inside the tunnel. Identified sources include resuspension (27%), diesel exhaust emissions (21%), petrol exhaust emissions (12%), brake wear emissions (11%) and road surface wear (11%). This study shows that major health related chemical species of PM10 originate from non-exhaust sources, further signifying the need for legislation to reduce these emissions.

  17. Calculated and measured brachytherapy dosimetry parameters in water for the Xoft Axxent X-Ray Source: an electronic brachytherapy source.

    Science.gov (United States)

    Rivard, Mark J; Davis, Stephen D; DeWerd, Larry A; Rusch, Thomas W; Axelrod, Steve

    2006-11-01

    A new x-ray source, the model S700 Axxent X-Ray Source (Source), has been developed by Xoft Inc. for electronic brachytherapy. Unlike brachytherapy sources containing radionuclides, this Source may be turned on and off at will and may be operated at variable currents and voltages to change the dose rate and penetration properties. The in-water dosimetry parameters for this electronic brachytherapy source have been determined from measurements and calculations at 40, 45, and 50 kV settings. Monte Carlo simulations of radiation transport utilized the MCNP5 code and the EPDL97-based mcplib04 cross-section library. Inter-tube consistency was assessed for 20 different Sources, measured with a PTW 34013 ionization chamber. As the Source is intended to be used for a maximum of ten treatment fractions, tube stability was also assessed. Photon spectra were measured using a high-purity germanium (HPGe) detector, and calculated using MCNP. Parameters used in the two-dimensional (2D) brachytherapy dosimetry formalism were determined. While the Source was characterized as a point due to the small anode size, S700 Source exhibited depth dose behavior similar to low-energy photon-emitting low dose rate sources 125I and l03Pd, yet with capability for variable and much higher dose rates and subsequently adjustable penetration capabilities. This paper presents the calculated and measured in-water brachytherapy dosimetry parameters for the model S700 Source at the aforementioned three operating voltages.

  18. Hippocampal volume measurement in patients with Meniere's disease : a pilot study

    NARCIS (Netherlands)

    van Cruijsen, Nynke; Hiemstra, Wilma M.; Meiners, Linda C.; Wit, Hero P.; Albers, Frans W. J.

    2007-01-01

    Conclusion. No signs of chronic stress as in hippocampal atrophy were present in patients with Meniere's disease. Objective. To evaluate the effect of chronic stress (allostatic load) by measuring hippocampal volume in patients with Meniere's disease. Subjects and methods. Ten patients with

  19. Calorimetric measurement of strong γ emitting sources

    International Nuclear Information System (INIS)

    Brangier, B.; Herczeg, C.; Henry, R.

    1968-01-01

    This publication gives the principle and a description of an adiabatic calorimeter for measuring the real activity of strong gamma-emitting sources by absorbing the emitted energy in a mass of copper. Because of the difficulty of evaluating the amount self- absorption, we have built a calorimeter for measuring the self- absorption, and a description of it is given.The results of these three measurements are fairly satisfactory. The calibration and the actual measurements obtained are given with a few corrections made necessary by the design of the apparatus. The correlation of the various results is discussed. (author) [fr

  20. Measuring Modularity in Open Source Code Bases

    Directory of Open Access Journals (Sweden)

    Roberto Milev

    2009-03-01

    Full Text Available Modularity of an open source software code base has been associated with growth of the software development community, the incentives for voluntary code contribution, and a reduction in the number of users who take code without contributing back to the community. As a theoretical construct, modularity links OSS to other domains of research, including organization theory, the economics of industry structure, and new product development. However, measuring the modularity of an OSS design has proven difficult, especially for large and complex systems. In this article, we describe some preliminary results of recent research at Carleton University that examines the evolving modularity of large-scale software systems. We describe a measurement method and a new modularity metric for comparing code bases of different size, introduce an open source toolkit that implements this method and metric, and provide an analysis of the evolution of the Apache Tomcat application server as an illustrative example of the insights gained from this approach. Although these results are preliminary, they open the door to further cross-discipline research that quantitatively links the concerns of business managers, entrepreneurs, policy-makers, and open source software developers.

  1. Micro CT based truth estimation of nodule volume

    Science.gov (United States)

    Kinnard, L. M.; Gavrielides, M. A.; Myers, K. J.; Zeng, R.; Whiting, B.; Lin-Gibson, S.; Petrick, N.

    2010-03-01

    With the advent of high-resolution CT, three-dimensional (3D) methods for nodule volumetry have been introduced, with the hope that such methods will be more accurate and consistent than currently used planar measures of size. However, the error associated with volume estimation methods still needs to be quantified. Volume estimation error is multi-faceted in the sense that there is variability associated with the patient, the software tool and the CT system. A primary goal of our current research efforts is to quantify the various sources of measurement error and, when possible, minimize their effects. In order to assess the bias of an estimate, the actual value, or "truth," must be known. In this work we investigate the reliability of micro CT to determine the "true" volume of synthetic nodules. The advantage of micro CT over other truthing methods is that it can provide both absolute volume and shape information in a single measurement. In the current study we compare micro CT volume truth to weight-density truth for spherical, elliptical, spiculated and lobulated nodules with diameters from 5 to 40 mm, and densities of -630 and +100 HU. The percent differences between micro CT and weight-density volume for -630 HU nodules range from [-21.7%, -0.6%] (mean= -11.9%) and the differences for +100 HU nodules range from [-0.9%, 3.0%] (mean=1.7%).

  2. Pleural liquid clearance rate measured in awake sheep by the volume of dilution method

    International Nuclear Information System (INIS)

    Broaddus, V.C.; Wiener-Kronish, J.P.; Berthiaume, Y.; Staub, N.C.

    1986-01-01

    The authors reported 24h clearance of mock pleural effusions measured terminally in sheep. To measure effusion volume at different times in the same sheep, they injected 111 In-transferrin and measured its dilution. In 5 sheep with effusions of known sizes, the method was accurate to +/-10%. In 5 awake sheep, the authors injected 10 ml/kg of a 1% protein solution via a non-penetrating rib capsule. At 6h, the authors measured the volume by the dilution method and at 24h by direct recovery. The clearance rate in each animal was constant at 2.9-6.0%/h (average 4.8 +/- 1.3%/h). This new method gives a reliable two point clearance rate and requires fewer animals

  3. Porosity, Bulk Density, and Volume Reduction During Drying: Review of Measurement Methods and Coefficient Determinations

    NARCIS (Netherlands)

    Qiu, J.; Khalloufi, S.; Martynenko, A.; Dalen, van G.; Schutyser, M.A.I.; Almeida-Rivera, C.

    2015-01-01

    Several experimental methods for measuring porosity, bulk density and volume reduction during drying of foodstuff are available. These methods include among others geometric dimension, volume displacement, mercury porosimeter, micro-CT, and NMR. However, data on their accuracy, sensitivity, and

  4. Volume weighting the measure of the universe from classical slow-roll expansion

    Science.gov (United States)

    Sloan, David; Silk, Joseph

    2016-05-01

    One of the most frustrating issues in early universe cosmology centers on how to reconcile the vast choice of universes in string theory and in its most plausible high energy sibling, eternal inflation, which jointly generate the string landscape with the fine-tuned and hence relatively small number of universes that have undergone a large expansion and can accommodate observers and, in particular, galaxies. We show that such observations are highly favored for any system whereby physical parameters are distributed at a high energy scale, due to the conservation of the Liouville measure and the gauge nature of volume, asymptotically approaching a period of large isotropic expansion characterized by w =-1 . Our interpretation predicts that all observational probes for deviations from w =-1 in the foreseeable future are doomed to failure. The purpose of this paper is not to introduce a new measure for the multiverse, but rather to show how what is perhaps the most natural and well-known measure, volume weighting, arises as a consequence of the conservation of the Liouville measure on phase space during the classical slow-roll expansion.

  5. Residual stress measurement using the pulsed neutron source at LANSCE

    International Nuclear Information System (INIS)

    Bourke, M.A.M.; Goldstone, J.A.; Holden, T.M.

    1991-01-01

    The presence of residual stress in engineering components can effect their mechanical properties and structural integrity. Neutron diffraction is the only measuring technique which can make spatially resolved non-destructive strain measurements in the interior of components. By recording the change in the crystalline interplanar spacing, elastic strains can be measured for individual lattice reflections. Using a pulsed neutron source, all the lattice reflections are recorded in each measurement which allows anisotropic effects to be studied. Measurements made at the Manuel Lujan Jr Neutron Scattering Centre (LANSCE) demonstrate the potential for stress measurements on a pulsed source and indicate the advantages and disadvantages over measurements made on a reactor. 15 refs., 7 figs

  6. Comparison between CT volume measurement and histopathological assessment of response to neoadjuvant therapy in rectal cancer

    Energy Technology Data Exchange (ETDEWEB)

    Pomerri, Fabio, E-mail: fabio.pomerri@unipd.it [Veneto Institute of Oncology IOV-IRCCS, via Gattamelata 64, 35128 Padua (Italy); Department of Medicine, University of Padua, via Giustiniani 2, 35128 Padua (Italy); Pucciarelli, Salvatore, E-mail: puc@unipd.it [Department of Oncological and Surgical Sciences, University of Padua, via Giustiniani 2, 35128 Padua (Italy); Gennaro, Gisella, E-mail: gisella.gennaro@pd.infn.it [Veneto Institute of Oncology IOV-IRCCS, via Gattamelata 64, 35128 Padua (Italy); Maretto, Isacco, E-mail: isac77@gmail.com [Veneto Institute of Oncology IOV-IRCCS, via Gattamelata 64, 35128 Padua (Italy); Nitti, Donato, E-mail: donato.nitti@unipd.it [Department of Oncological and Surgical Sciences, University of Padua, via Giustiniani 2, 35128 Padua (Italy); Muzzio, Pier Carlo, E-mail: pcmuzzio@unipd.it [Veneto Institute of Oncology IOV-IRCCS, via Gattamelata 64, 35128 Padua (Italy)

    2012-12-15

    Objectives: The aim of this study was to compare volume measurements on computed tomography (CT) images with histopathological assessments of chemoradiotherapy (CRT)-induced tumor regression in locally advanced rectal cancer (RC). Methods: In 25 patients (13 males, 12 females; median age, 63 years; age range, 44–79 years) with locally advanced RC treated with preoperative CRT and surgery, two radiologists measured tumor volume on CT images before and after CRT. CT-based tumor volumetry and the modified response evaluation criteria in solid tumors (mRECISTs) were compared with T and N downstaging after CRT, and with the tumor regression grade (TRG). Results: Tumor volumes were significantly smaller on CT images after CRT. The tumors regressed in 52% (13/25), 36% (9/25) and 40% (10/25) of patients, based on T downstaging, TRG and mRECIST findings, respectively. In terms of T downstaging, the pre- and post-CRT tumor volumes of responders and non-responders to the treatment differed statistically, while their tumor volume reduction rates and volume reductions according to the 65% mRECIST threshold did not. In terms of N downstaging and TRG, the differences between the responders’ and the non-responders’ pre- and post-CRT tumor volumes, tumor volume reduction rates, and mRECIST thresholds were never statistically significant. Conclusion: Measuring tumor size on CT images is of limited value in predicting the histopathological response to preoperative CRT in RC patients, so it may be unwise to select surgical treatment strategies based on CT volumetry.

  7. Limitations and pitfalls in measurements of right ventricular stroke volume in an animal model of right heart failure

    International Nuclear Information System (INIS)

    Vildbrad, Mads Dam; Andersen, Asger; Andersen, Thomas Krarup; Axelgaard, Sofie; Holmboe, Sarah; Andersen, Stine; Nielsen-Kudsk, Jens Erik; Ringgaard, Steffen

    2015-01-01

    Right heart failure occurs in various heart and pulmonary vascular diseases and may be fatal. We aimed to identify limitations in non-invasive measurements of right ventricular stroke volume in an animal model of right ventricular failure. Data from previous studies randomising rats to pulmonary trunk banding (PTB, n = 33) causing pressure-overload right ventricular failure or sham operation (n = 16) was evaluated retrospectively. We measured right ventricular stroke volume by high frequency echocardiography and magnetic resonance imaging (MRI). We found correlation between right ventricular stroke volume measured by echocardiography and MRI in the sham animals (r = 0.677, p = 0.004) but not in the PTB group. Echocardiography overestimated the stroke volume compared to MRI in both groups. Intra- and inter-observer variation did not explain the difference. Technical, physiological and anatomical issues in the pulmonary artery might explain why echocardiography over-estimates stroke volume. Flow acceleration close to the pulmonary artery banding can cause uncertainties in the PTB model and might explain the lack of correlation. In conclusion, we found a correlation in right ventricular stroke volume measured by echocardiography versus MRI in the sham group but not the PTB group. Echocardiography overestimated right ventricular stroke volume compared to MRI. (paper)

  8. Stable source reconstruction from a finite number of measurements in the multi-frequency inverse source problem

    DEFF Research Database (Denmark)

    Karamehmedovic, Mirza; Kirkeby, Adrian; Knudsen, Kim

    2018-01-01

    setting: From measurements made at a finite set of frequencies we uniquely determine and reconstruct sources in a subspace spanned by finitely many Fourier-Bessel functions. Further, we obtain a constructive criterion for identifying a minimal set of measurement frequencies sufficient for reconstruction......, and under an additional, mild assumption, the reconstruction method is shown to be stable." Our analysis is based on a singular value decomposition of the source-to-measurement forward operators and the distribution of positive zeros of the Bessel functions of the first kind. The reconstruction method...

  9. Block Volume Estimation from the Discontinuity Spacing Measurements of Mesozoic Limestone Quarries, Karaburun Peninsula, Turkey

    OpenAIRE

    Elci, Hakan; Turk, Necdet

    2014-01-01

    Block volumes are generally estimated by analyzing the discontinuity spacing measurements obtained either from the scan lines placed over the rock exposures or the borehole cores. Discontinuity spacing measurements made at the Mesozoic limestone quarries in Karaburun Peninsula were used to estimate the average block volumes that could be produced from them using the suggested methods in the literature. The Block Quality Designation (BQD) ratio method proposed by the authors has been found to ...

  10. Relative strengths of the calf muscles based on MRI volume measurements.

    Science.gov (United States)

    Jeng, Clifford L; Thawait, Gaurav K; Kwon, John Y; Machado, Antonio; Boyle, James W; Campbell, John; Carrino, John A

    2012-05-01

    In 1985, Silver et al. published a cadaver study which determined the relative order of strength of the muscles in the calf. Muscle strength, which is proportional to volume, was obtained by dissecting out the individual muscles, weighing them, and then multiplying by the specific gravity. No similar studies have been performed using {\\it in vivo} measurements of muscle volume. Ten normal subjects underwent 3-Tesla MRI's of both lower extremities using non-fat-saturated T2 SPACE sequences. The volume for each muscle was determined by tracing the muscle contour on sequential axial images and then interpolating the volume using imaging software. The results from this study differ from Silver's original article. The lateral head of the gastrocnemius was found to be stronger than the tibialis anterior muscle. The FHL and EDL muscles were both stronger than the peroneus longus. There was no significant difference in strength between the peroneus longus and brevis muscles. This revised order of muscle strengths in the calf based on in vivo MRI findings may assist surgeons in determining the optimal tendons to transfer in order to address muscle weakness and deformity.

  11. Metabolic tumour volumes measured at staging in lymphoma: methodological evaluation on phantom experiments and patients

    International Nuclear Information System (INIS)

    Meignan, Michel; Sasanelli, Myriam; Itti, Emmanuel; Casasnovas, Rene Olivier; Luminari, Stefano; Fioroni, Federica; Coriani, Chiara; Masset, Helene; Gobbi, Paolo G.; Merli, Francesco; Versari, Annibale

    2014-01-01

    The presence of a bulky tumour at staging on CT is an independent prognostic factor in malignant lymphomas. However, its prognostic value is limited in diffuse disease. Total metabolic tumour volume (TMTV) determined on 18 F-FDG PET/CT could give a better evaluation of the total tumour burden and may help patient stratification. Different methods of TMTV measurement established in phantoms simulating lymphoma tumours were investigated and validated in 40 patients with Hodgkin lymphoma and diffuse large B-cell lymphoma. Data were processed by two nuclear medicine physicians in Reggio Emilia and Creteil. Nineteen phantoms filled with 18 F-saline were scanned; these comprised spherical or irregular volumes from 0.5 to 650 cm 3 with tumour-to-background ratios from 1.65 to 40. Volumes were measured with different SUVmax thresholds. In patients, TMTV was measured on PET at staging by two methods: volumes of individual lesions were measured using a fixed 41 % SUVmax threshold (TMTV 41 ) and a variable visually adjusted SUVmax threshold (TMTV var ). In phantoms, the 41 % threshold gave the best concordance between measured and actual volumes. Interobserver agreement was almost perfect. In patients, the agreement between the reviewers for TMTV 41 measurement was substantial (ρ c = 0.986, CI 0.97 - 0.99) and the difference between the means was not significant (212 ± 218 cm 3 for Creteil vs. 206 ± 219 cm 3 for Reggio Emilia, P = 0.65). By contrast the agreement was poor for TMTV var . There was a significant direct correlation between TMTV 41 and normalized LDH (r = 0.652, CI 0.42 - 0.8, P 41 , but high TMTV 41 could be found in patients with stage 1/2 or nonbulky tumour. Measurement of baseline TMTV in lymphoma using a fixed 41% SUVmax threshold is reproducible and correlates with the other parameters for tumour mass evaluation. It should be evaluated in prospective studies. (orig.)

  12. Metabolic tumour volumes measured at staging in lymphoma: methodological evaluation on phantom experiments and patients

    Energy Technology Data Exchange (ETDEWEB)

    Meignan, Michel [Hopital Henri Mondor and Paris-Est University, Department of Nuclear Medicine, Creteil (France); Paris-Est University, Service de Medecine Nucleaire, EAC CNRS 7054, Hopital Henri Mondor AP-HP, Creteil (France); Sasanelli, Myriam; Itti, Emmanuel [Hopital Henri Mondor and Paris-Est University, Department of Nuclear Medicine, Creteil (France); Casasnovas, Rene Olivier [CHU Le Bocage, Department of Hematology, Dijon (France); Luminari, Stefano [University of Modena and Reggio Emilia, Department of Diagnostic, Clinic and Public Health Medicine, Modena (Italy); Fioroni, Federica [Santa Maria Nuova Hospital-IRCCS, Department of Medical Physics, Reggio Emilia (Italy); Coriani, Chiara [Santa Maria Nuova Hospital-IRCCS, Department of Radiology, Reggio Emilia (Italy); Masset, Helene [Henri Mondor Hospital, Department of Radiophysics, Creteil (France); Gobbi, Paolo G. [University of Pavia, Department of Internal Medicine and Gastroenterology, Fondazione IRCCS Policlinico San Matteo, Pavia (Italy); Merli, Francesco [Santa Maria Nuova Hospital-IRCCS, Department of Hematology, Reggio Emilia (Italy); Versari, Annibale [Santa Maria Nuova Hospital-IRCCS, Department of Nuclear Medicine, Reggio Emilia (Italy)

    2014-06-15

    The presence of a bulky tumour at staging on CT is an independent prognostic factor in malignant lymphomas. However, its prognostic value is limited in diffuse disease. Total metabolic tumour volume (TMTV) determined on {sup 18}F-FDG PET/CT could give a better evaluation of the total tumour burden and may help patient stratification. Different methods of TMTV measurement established in phantoms simulating lymphoma tumours were investigated and validated in 40 patients with Hodgkin lymphoma and diffuse large B-cell lymphoma. Data were processed by two nuclear medicine physicians in Reggio Emilia and Creteil. Nineteen phantoms filled with {sup 18}F-saline were scanned; these comprised spherical or irregular volumes from 0.5 to 650 cm{sup 3} with tumour-to-background ratios from 1.65 to 40. Volumes were measured with different SUVmax thresholds. In patients, TMTV was measured on PET at staging by two methods: volumes of individual lesions were measured using a fixed 41 % SUVmax threshold (TMTV{sub 41}) and a variable visually adjusted SUVmax threshold (TMTV{sub var}). In phantoms, the 41 % threshold gave the best concordance between measured and actual volumes. Interobserver agreement was almost perfect. In patients, the agreement between the reviewers for TMTV{sub 41} measurement was substantial (ρ {sub c} = 0.986, CI 0.97 - 0.99) and the difference between the means was not significant (212 ± 218 cm{sup 3} for Creteil vs. 206 ± 219 cm{sup 3} for Reggio Emilia, P = 0.65). By contrast the agreement was poor for TMTV{sub var}. There was a significant direct correlation between TMTV{sub 41} and normalized LDH (r = 0.652, CI 0.42 - 0.8, P <0.001). Higher disease stages and bulky tumour were associated with higher TMTV{sub 41}, but high TMTV{sub 41} could be found in patients with stage 1/2 or nonbulky tumour. Measurement of baseline TMTV in lymphoma using a fixed 41% SUVmax threshold is reproducible and correlates with the other parameters for tumour mass evaluation

  13. Residual volume measurements in CAPD patients with exogenous and endogenous solutes

    NARCIS (Netherlands)

    Imholz, A. L.; Koomen, G. C.; Struijk, D. G.; Arisz, L.; Krediet, R. T.

    1992-01-01

    Accurate residual volume (RV) measurements are needed in studies on fluid kinetics during CAPD. In this study 10 stable CAPD patients were examined twice within 1 week. On both occasions RV after drainage was calculated by the indicator dilution method. Exogenous (dextran 70, inulin) and endogenous

  14. Oceans circulation and electron cyclotron resonance sources: Measurement of the AR-39 isotopic ratio in Seawater

    International Nuclear Information System (INIS)

    Gaelens, M.; Loiselet, M.; Ryckewaert, G.; Pardo, R.C.; Scott, R.H.; Vondrasek, R.; Collon, Ph.; Kutchera, W.

    2004-01-01

    The radionuclide 39 Ar is produced in the atmosphere by cosmic rays and has an isotopic abundance of 8.1x10 -16 . Because its half life (T 1/2 =269 years) is well matched to the time periods involved in the oceanic currents around the Earth, the measurement of the 39 Ar isotopic ratio is an ideal tool to date ocean water from different depths. It would complement the information gained by the 14 C measurements (T 1/2 =5730 years). However, the measurement of the isotopic ratio 39 Ar/ 40 Ar is a technical challenge: 1 L of modern ocean water contains ∼6500 atoms of 39 Ar, and produces ∼17 decays per year. Although it has been possible to detect the 39 Ar decays in large volumes of sea water by using the low level counting technique, the possibility of measuring the number of 39 Ar atoms faster and in smaller samples using the accelerator mass spectrometry (AMS) technique would be a major breakthrough for this type of measurement. The development of a viable AMS method for 39 Ar has been underway for several years at Argonne National Laboratory, and is presently hampered by the presence of stable 39 K ions coming from the ion source. Although the intensity of this isobaric contaminant is low (∼pA extracted from the source), it has to be compared with the 39 Ar beam intensity (atoms per minutes). In order to separate these two beams (whose mass difference is only 1.6x10 -5 ), the intensity of the 39 K beam coming from the ion source has to be reduced by several orders of magnitude. This reduction has been investigated both at Argonne National Laboratory and at Louvain-la-Neuve. Two techniques have been tried out. In the first, a quartz liner is used to provide a clean surface, while in the second these impurities are buried in a SiO 2 layer formed in situ by running the source with a mixture of silane and oxygen. The 39 K background has been reduced by a factor of 100 with these treatments. These techniques and their results obtained both at Argonne and Louvain

  15. Measurement of breast volume is a useful supplement to select candidates for surgical breast reduction

    DEFF Research Database (Denmark)

    Ikander, Peder; Drejøe, Jennifer Berg; Lumholt, Pavia

    2014-01-01

    for breast reduction surgery, thus establishing a standard decision basis that can be shared by surgeons and departments to secure patients fair and equal treatment opportunities. MATERIAL AND METHODS: A total of 427 patients who were referred to three Danish public hospitals with breast hypertrophy...... in the period from January 2007 to March 2011 were included prospectively in the study. The patients' subjective complaints, height, weight and standard breast measurements were registered as well as the decision for or against surgery. Breast volume was measured using transparent plastic cups. RESULTS: Cut......-off values for breast volume were calculated based on whether or not the patients were offered reduction surgery. Most patients (93%) with a breast volume below 800 cc were not offered surgery, while most with a volume exceeding 900 cc were offered surgery (94%). In the grey zone between 800 and 900 cc...

  16. Numerical study of cesium effects on negative ion production in volume sources

    Energy Technology Data Exchange (ETDEWEB)

    Fukumasa, Osamu; Niitani, Eiji [Yamaguchi Univ., Ube (Japan). Faculty of Engineering

    1997-02-01

    Effects of cesium vapor injection of H{sup -} production in a tandem negative ion source are studied numerically as a function of plasma parameters. Model calculation is done by solving a set of particle balance equations in a steady-state hydrogen discharge plasmas. Here, the results which focus on gas pressure and electron temperature dependences of H{sup -} volume production are presented and discussed. With including H{sup -} surface production processes caused by both H atoms and positive hydrogen ions, enhancement of H{sup -} production and pressure dependence of H{sup -} production observed experimentally are well reproduced in the model. To enhance H{sup -} production, however, so-called electron cooling is not so effective if plasma parameters are initially optimized with the use of magnetic filter. (author)

  17. Directivity of Spherical Polyhedron Sound Source Used in Near-Field HRTF Measurements

    International Nuclear Information System (INIS)

    Yu Guang-Zheng; Xie Bo-Sun; Rao Dan

    2010-01-01

    The omnidirectional character is one of important requirements for the sound source used in near-field head-related transfer function (HRTF) measurements. Based on the analysis on the radiation sound pressure and directivity character of various spherical polyhedron sound sources, a spherical dodecahedral sound source with radius of 0.035m is proposed and manufactured. Theoretical and measured results indicate that the sound source is approximately omnidirectional below the frequency of 8 kHz. In addition, the sound source has reasonable magnitude response from 350Hz to 20kHz and linear phase characteristics. Therefore, it is suitable for the near-field HRTF measurements. (fundamental areas of phenomenology(including applications))

  18. Lunar occultations for gamma-ray source measurements

    Science.gov (United States)

    Koch, David G.; Hughes, E. B.; Nolan, Patrick L.

    1990-01-01

    The unambiguous association of discrete gamma-ray sources with objects radiating at other wavelengths, the separation of discrete sources from the extended emission within the Galaxy, the mapping of gamma-ray emission from nearby galaxies and the measurement of structure within a discrete source cannot presently be accomplished at gamma-ray energies. In the past, the detection processes used in high-energy gamma-ray astronomy have not allowed for good angular resolution. This problem can be overcome by placing gamma-ray detectors on the moon and using the horizon as an occulting edge to achieve arcsec resolution. For purposes of discussion, this concept is examined for gamma rays above 100 MeV for which pair production dominates the detection process and locally-generated nuclear gamma rays do not contribute to the background.

  19. Time-specific measurements of energy deposition from radiation fields in simulated sub-micron tissue volumes

    International Nuclear Information System (INIS)

    Famiano, M.A.

    1997-01-01

    A tissue-equivalent spherical proportional counter is used with a modified amplifier system to measure specific energy deposited from a uniform radiation field for short periods of time (∼1 micros to seconds) in order to extrapolate to dose in sub-micron tissue volumes. The energy deposited during these time intervals is compared to biological repair processes occurring within the same intervals after the initial energy deposition. The signal is integrated over a variable collection time which is adjusted with a square-wave pulse. Charge from particle passages is collected on the anode during the period in which the integrator is triggered, and the signal decays quickly to zero after the integrator feedback switch resets; the process repeats for every triggering pulse. Measurements of energy deposited from x rays, 137 Cs gamma rays, and electrons from a 90 Sr/ 90 Y source for various time intervals are taken. Spectral characteristics as a function of charge collection time are observed and frequency plots of specific energy and collection time-interval are presented. In addition, a threshold energy flux is selected for each radiation type at which the formation of radicals (based on current measurements) in mammalian cells equals the rate at which radicals are repaired

  20. Improved wrist pannus volume measurement from contrast-enhanced MRI in rheumatoid arthritis using shuffle transform.

    Science.gov (United States)

    Xanthopoulos, Emily; Hutchinson, Charles E; Adams, Judith E; Bruce, Ian N; Nash, Anthony F P; Holmes, Andrew P; Taylor, Christopher J; Waterton, John C

    2007-01-01

    Contrast-enhanced MRI is of value in assessing rheumatoid pannus in the hand, but the images are not always easy to quantitate. To develop and evaluate an improved measurement of volume of enhancing pannus (VEP) in the hand in human rheumatoid arthritis (RA). MR images of the hand and wrist were obtained for 14 patients with RA at 0, 1 and 13 weeks. Volume of enhancing pannus was measured on images created by subtracting precontrast T1-weighted images from contrast-enhanced T1-weighted images using a shuffle transformation technique. Maximum intensity projection (MIP) and 3D volume rendering of the images were used as a guide to identify the pannus and any contrast-enhanced veins. Visualisation of pannus was much improved following the shuffle transform. Between 0 weeks and 1 week, the mean value of the within-subject coefficient of variation (CoV) was 0.13 and the estimated total CoV was 0.15. There was no evidence of significant increased variability within the 13-week interval for the complete sample of patients. Volume of enhancing pannus can be measured reproducibly in the rheumatoid hand using 3D contrast-enhanced MRI and shuffle transform.

  1. Hidden sources of mercury in clinical laboratories.

    Science.gov (United States)

    Alvarez-Chavez, C R; Federico-Perez, R A; Gomez-Alvarez, A; Velazquez-Contreras, L E; Perez-Rios, R

    2014-09-01

    The healthcare sector is an important contributor to mercury (Hg) pollution because of the potential presence of mercury in thermometers, blood pressure cuffs, amalgams, etc. There are also other potential sources of mercury in this sector which are used frequently and in high volumes where the presence of the metal is not obvious and which might be collectively contributing to pollution. For instance, some chemicals used for the clinical diagnosis of illness may contain mercury. The goal of this study was to investigate potential sources of mercury pollution, which originate from clinical laboratory discharges, using an exploratory approach. The focus was on the residue generated during automatic analysis of patients' bodily fluids at a medical center in Hermosillo, Sonora, Mexico. This study shows an overview of what might be happening in the region or the country related to non-obvious sources of mercury in the healthcare sector. The results showed measurable levels of mercury in the residues coming from urine sediment analysis. These amounts do not exceed the maximum allowed by Mexican environmental regulations; nevertheless, the frequency and cumulative volume of residues generated, combined with the potential for persistence and the bioaccumulation of mercury in the environment, warrant attention. The work carried out in this study is being taken as a model for future studies for pollution prevention in the healthcare sector with the goal of measuring mercury emissions to the environment from clinical laboratory wastewater, including identifying sources which--while not obvious--could be important given the frequency and volume of their use in the clinical diagnosis.

  2. Intra- and interobserver variability of thyroid volume measurements in healthy adults by 2D versus 3D ultrasound

    International Nuclear Information System (INIS)

    Andermann, P.; Schloegl, S.; Maeder, U.; Luster, M.; Lassmann, M.; Reiners, C.

    2007-01-01

    Thyroid volume measurement by ultrasonography (US) is essential in numerous clinical diagnostic and therapeutic fields. While known to be limited, the accuracy and precision of two-dimensional (2D) US thyroid volume measurement have not been thoroughly characterized. Objective: We sought to assess the intra- and interobserver variability, accuracy and precision of thyroid volume determination by conventional 2D US in healthy adults using reference volumes determined by three-dimensional (3D) US. Design, methods: In a prospective blinded trial, thyroid volumes of ten volunteers were determined repeatedly by nine experienced sonographers using conventional 2D US (ellipsoid model). The values obtained were statistically compared to the so-called true volumes determined by 3D US (multiplanar approximation), the so-called gold standard, to estimate systematic errors and relative deviations of individual observers. Results: The standard error of measurement (SEM) for one observer and successive measurements (intraobserver variability), was 14%, and for different observers and repeated measurements (interobserver variability), 17%. The minimum relative thyroid volume change significantly different at the 95% level was 39% for the same observer and 46% for different observers. Regarding accuracy, the mean value of the differences showed a significant thyroid volume overestimation (17%, p <0.01) by 2D relative to 3D US. Conclusion: 2D US is appropriate for routine thyroid volumetry. Nevertheless, the so-called human factor (random error) should be kept in mind and correction is needed for methodical bias (systematic error). Further efforts are required to improve the accuracy and precision of 2D US thyroid volumetry by optimizing the underlying geometrical modeling or by the application of 3D US. (orig.)

  3. Flux density measurements of radio sources at 2.14 millimeter wavelength

    International Nuclear Information System (INIS)

    Cogdell, J.R.; Davis, J.H.; Ulrich, B.T.; Wills, B.J.

    1975-01-01

    Flux densities of galactic and extragalactic sources, and planetary temperatures, have been measured at 2.14 mm wavelength (140 GHz). Results are presented for OJ 287; the galactic sources DR 21, W3, and Orion A; the extragalactic sources PKS 0106plus-or-minus01, 3C 84, 3C 120, BL Lac, 3C 216, 3C 273, 3C 279, and NGC 4151; and the Sun, Venus, Mars, and Jupiter. Also presented is the first measurement of the 2.14-mm temperature of Uranus. The spectra of some of these sources are discussed. The flux density scale was calibrated absolutely. The measurements were made with a new continuum receiver on the 4.88-m radio telescope of The University of Texas

  4. Reheating-volume measure in the string theory landscape

    International Nuclear Information System (INIS)

    Winitzki, Sergei

    2008-01-01

    I recently proposed the ''reheating-volume'' (RV) prescription as a possible solution to the measure problem in ''multiverse'' cosmology. The goal of this work is to extend the RV measure to scenarios involving bubble nucleation, such as the string theory landscape. In the spirit of the RV prescription, I propose to calculate the distribution of observable quantities in a landscape that is conditioned in probability to nucleate a finite total number of bubbles to the future of an initial bubble. A general formula for the relative number of bubbles of different types can be derived. I show that the RV measure is well defined and independent of the choice of the initial bubble type, as long as that type supports further bubble nucleation. Applying the RV measure to a generic landscape, I find that the abundance of Boltzmann brains is always negligibly small compared with the abundance of ordinary observers in the bubbles of the same type. As an illustration, I present explicit results for a toy landscape containing four vacuum states, and for landscapes with a single high-energy vacuum and a large number of low-energy vacua.

  5. Stability check source measurements with a secondary standard dosimeter in SSDL-Pakistan

    International Nuclear Information System (INIS)

    Salman, S.; Mahmoud, K.; Orfi, S.D.

    1988-01-01

    The stability check source is an integral part of a Secondary Standard Dosimetry System. The purpose of the stability check source is to confirm that the overall response of the dosimeter has not changed significantly since the instrument was calibrated. In case any change in the sensitivity of the ionization chamber or measuring assembly occurs the same is reflected in the reference check source measurements. Stability check source measurements are taken in a Primary Standard Dosimetry Laboratory (PSDL) at the time of calibration of secondary standard dosimeter and mean time (in seconds) to the reference setting of 50 scale divisions with ambient conditions of air at 20 deg. C, 101.3 kPa and 50% RH is quoted in a calibration certificate. This quoted stability check source time figure is the basis for future confirmation of overall response of the secondary standard dosimeter system. This note presents the results of stability check source measurements carried out in SSDL Pakistan over a period of five years

  6. Low noise constant current source for bias dependent noise measurements

    International Nuclear Information System (INIS)

    Talukdar, D.; Bose, Suvendu; Bardhan, K. K.; Chakraborty, R. K.

    2011-01-01

    A low noise constant current source used for measuring the 1/f noise in disordered systems in ohmic as well as nonohmic regime is described. The source can supply low noise constant current starting from as low as 1 μA to a few tens of milliampere with a high voltage compliance limit of around 20 V. The constant current source has several stages, which can work in a standalone manner or together to supply the desired value of load current. The noise contributed by the current source is very low in the entire current range. The fabrication of a low noise voltage preamplifier modified for bias dependent noise measurements and based on the existing design available in the MAT04 data sheet is also described.

  7. Air Pollution Translations: A Bibliography with Abstracts - Volume 2.

    Science.gov (United States)

    National Air Pollution Control Administration (DHEW), Raleigh, NC.

    This volume is the second in a series of compilations presenting abstracts and indexes of translations of technical air pollution literature. The 444 entries are grouped into 12 subject categories: General; Emission Sources; Atmospheric Interaction; Measurement Methods; Control Methods; Effects--Human Health; Effects--Plants and Livestock;…

  8. A gamma-source method of measuring soil moisture

    International Nuclear Information System (INIS)

    Al-Jeboori, M.A.; Ameen, I.A.

    1986-01-01

    Water content in soil column was measured using NaI scintillation detector 5 mci Cs-137 as a gamma source. The measurements were done with a back scatter gauge, restricted with scattering angle less to than /2 overcome the effect of soil type. A 3 cm air gap was maintained between the front of the detector and the wall of the soil container in order to increase the counting rate. The distance between the center of the source and the center of the back scattering detector was 14 cm. The accuracy of the measurements was 0.63. For comparision, a direct rays method was used to measure the soil moisture. The results gave an error of 0.65. Results of the two methods were compared with the gravimetric method which gave an error of 0.18 g/g and 0.17 g/g for direct and back method respectively. The quick direct method was used to determine the gravimetric and volumetric percentage constants, and were found to be 1.62 and 0.865 respectively. The method then used to measure the water content in the layers of soil column.(6 tabs., 4 figs., 12 refs.)

  9. Calculated and measured brachytherapy dosimetry parameters in water for the Xoft Axxent X-Ray Source: An electronic brachytherapy source

    International Nuclear Information System (INIS)

    Rivard, Mark J.; Davis, Stephen D.; DeWerd, Larry A.; Rusch, Thomas W.; Axelrod, Steve

    2006-01-01

    A new x-ray source, the model S700 Axxent trade mark sign X-Ray Source (Source), has been developed by Xoft Inc. for electronic brachytherapy. Unlike brachytherapy sources containing radionuclides, this Source may be turned on and off at will and may be operated at variable currents and voltages to change the dose rate and penetration properties. The in-water dosimetry parameters for this electronic brachytherapy source have been determined from measurements and calculations at 40, 45, and 50 kV settings. Monte Carlo simulations of radiation transport utilized the MCNP5 code and the EPDL97-based mcplib04 cross-section library. Inter-tube consistency was assessed for 20 different Sources, measured with a PTW 34013 ionization chamber. As the Source is intended to be used for a maximum of ten treatment fractions, tube stability was also assessed. Photon spectra were measured using a high-purity germanium (HPGe) detector, and calculated using MCNP. Parameters used in the two-dimensional (2D) brachytherapy dosimetry formalism were determined. While the Source was characterized as a point due to the small anode size, P (5) were 0.20, 0.24, and 0.29 for the 40, 45, and 50 kV voltage settings, respectively. For 1 125 I and 103 Pd, yet with capability for variable and much higher dose rates and subsequently adjustable penetration capabilities. This paper presents the calculated and measured in-water brachytherapy dosimetry parameters for the model S700 Source at the aforementioned three operating voltages

  10. Security measures in transport of radiation source in Jordan

    Energy Technology Data Exchange (ETDEWEB)

    Mohammad, Alslman [Korea Advanced Institute of Science and Technology, Kaist Daejeon (Korea, Republic of); Choi, Kwang Sik [Korea Institute of Nuclear Safety, Daejeon (Korea, Republic of)

    2011-05-15

    Radioactive materials are used in Jordan for peaceful applications in medicine, industry, agriculture, environmental science, education and research and military applications. Most of these radioactive sources used are imported, therefore trans-boundary movement is a significant factor in consideration of security measures during movement of these sources. After 11/9 2001 event, IAEA efforts began to focus and concentrate on security in transport of radioactive materials, after the emergence of risks of using these sources in terrorist activities. In 2002, Efforts were initiated by the IAEA to provide additional guidance for security in the transport of radioactive materials, based upon the new security requirements in the Recommendations on the Transport of Dangerous Goods. This paper reviews some of the measures relating to the transport of radioactive materials in Jordan

  11. Preparation method and quality control of multigamma volume sources with different matrices.

    Science.gov (United States)

    Listkowska, A; Lech, E; Saganowski, P; Tymiński, Z; Dziel, T; Cacko, D; Ziemek, T; Kołakowska, E; Broda, R

    2018-04-01

    The aim of the work was to develop new radioactive standard sources based on epoxy resins. The optimal proportions of the components and the homogeneity of the matrices were determined. The activity of multigamma sources prepared in Marinelli beakers was determined with reference to the National Standard of Radionuclides Activity in Poland. The difference of radionuclides activity values determined using calibrated gamma spectrometer and the activity of standard solutions used are in most cases significantly lower than measurement uncertainty limits. Sources production method and quality control procedure have been developed. Copyright © 2017 Elsevier Ltd. All rights reserved.

  12. New experimental procedure for measuring volume magnetostriction on powder samples

    International Nuclear Information System (INIS)

    Rivero, G.; Multigner, M.; Valdes, J.; Crespo, P.; Martinez, A.; Hernando, A.

    2005-01-01

    Conventional techniques used for volume magnetostriction measurements, as strain gauge or cantilever method, are very useful for ribbons or thin films but cannot be applied when the samples are in powder form. To overcome this problem a new experimental procedure has been developed. In this work, the experimental set-up is described, together with the results obtained in amorphous FeCuZr powders, which exhibit a strong dependence of the magnetization on the strength of the applied magnetic field. The magnetostriction measurements presented in this work point out that this dependence is related to a magnetovolume effect

  13. Measurement of tidal volume using respiratory ultrasonic plethysmography in anaesthetized, mechanically ventilated horses.

    Science.gov (United States)

    Russold, Elena; Ambrisko, Tamas D; Schramel, Johannes P; Auer, Ulrike; Van Den Hoven, Rene; Moens, Yves P

    2013-01-01

    To compare tidal volume estimations obtained from Respiratory Ultrasonic Plethysmography (RUP) with simultaneous spirometric measurements in anaesthetized, mechanically ventilated horses. Prospective randomized experimental study. Five experimental horses. Five horses were anaesthetized twice (1 week apart) in random order in lateral and in dorsal recumbency. Nine ventilation modes (treatments) were scheduled in random order (each lasting 4 minutes) applying combinations of different tidal volumes (8, 10, 12 mL kg(-1)) and positive end-expiratory pressures (PEEP) (0, 10, 20 cm H(2)O). Baseline ventilation mode (tidal volume=15 mL kg(-1), PEEP=0 cm H(2)O) was applied for 4 minutes between all treatments. Spirometry and RUP data were downloaded to personal computers. Linear regression analyses (RUP versus spirometric tidal volume) were performed using different subsets of data. Additonally RUP was calibrated against spirometry using a regression equation for all RUP signal values (thoracic, abdominal and combined) with all data collectively and also by an individually determined best regression equation (highest R(2)) for each experiment (horse versus recumbency) separately. Agreement between methods was assessed with Bland-Altman analyses. The highest correlation of RUP and spirometric tidal volume (R(2)=0.81) was found with the combined RUP signal in horses in lateral recumbency and ventilated without PEEP. The bias ±2 SD was 0±2.66 L when RUP was calibrated for collective data, but decreased to 0±0.87 L when RUP was calibrated with individual data. A possible use of RUP for tidal volume measurement during IPPV needs individual calibration to obtain limits of agreement within ±20%. © 2012 The Authors. Veterinary Anaesthesia and Analgesia. © 2012 Association of Veterinary Anaesthetists and the American College of Veterinary Anesthesiologists.

  14. Measurement of liver and spleen volume by computed tomography using point counting technique in chronic liver disease

    International Nuclear Information System (INIS)

    Sato, Hiroyuki

    1983-01-01

    Liver and spleen volume were measured by computed tomography (CT) using point counting technique. This method is very simple and applicable to any kind of CT scanner. The volumes of the livers and spleens estimated by this method correlated with the weights of the corresponding organs measured on autopsy or surgical operation, indication the accuracy and usefulness of this method. Hepatic and splenic volumes were estimated by this method in 48 patients with chronic liver disease and 13 subjects with non-hepatobiliary discase. The mean hepatic volume in non-alcoholic liver cirrhosis but not in alcoholic cirrhosis was significantly smaller than those in non-hepatobiliary disease and other chronic liver diseases. Alcoholic cirrhosis showed significantly larger liver volume than non-alcoholic cirrhosis. In alcoholic fibrosis, the mean hepatic volume was significantly larger than non-hepatobiliary disease. The mean splenic volumes both in alcoholic and non-alcoholic cirrhosis were significantly larger than in other disease. A significantly positive correlation between hepatic and splenic volumes was found in alcoholic cirrhosis but not in non-alcoholic cirrhosis. These results indicate that estimation of hepatic and splenic volumes by this method is useful for the analysis of the pathophysiology of chronic liver disease. (author)

  15. 3D thoracoscopic ultrasound volume measurement validation in an ex vivo and in vivo porcine model of lung tumours

    International Nuclear Information System (INIS)

    Hornblower, V D M; Yu, E; Fenster, A; Battista, J J; Malthaner, R A

    2007-01-01

    The purpose of this study was to validate the accuracy and reliability of volume measurements obtained using three-dimensional (3D) thoracoscopic ultrasound (US) imaging. Artificial 'tumours' were created by injecting a liquid agar mixture into spherical moulds of known volume. Once solidified, the 'tumours' were implanted into the lung tissue in both a porcine lung sample ex vivo and a surgical porcine model in vivo. 3D US images were created by mechanically rotating the thoracoscopic ultrasound probe about its long axis while the transducer was maintained in close contact with the tissue. Volume measurements were made by one observer using the ultrasound images and a manual-radial segmentation technique and these were compared with the known volumes of the agar. In vitro measurements had average accuracy and precision of 4.76% and 1.77%, respectively; in vivo measurements had average accuracy and precision of 8.18% and 1.75%, respectively. The 3D thoracoscopic ultrasound can be used to accurately and reproducibly measure 'tumour' volumes both in vivo and ex vivo

  16. 3D thoracoscopic ultrasound volume measurement validation in an ex vivo and in vivo porcine model of lung tumours

    Energy Technology Data Exchange (ETDEWEB)

    Hornblower, V D M [Canadian Surgical Technologies and Advanced Robotics, London, Ontario (Canada); Yu, E [Canadian Surgical Technologies and Advanced Robotics, London, Ontario (Canada); Fenster, A [Canadian Surgical Technologies and Advanced Robotics, London, Ontario (Canada); Battista, J J [Canadian Surgical Technologies and Advanced Robotics, London, Ontario (Canada); Malthaner, R A [Canadian Surgical Technologies and Advanced Robotics, London, Ontario (Canada)

    2007-01-07

    The purpose of this study was to validate the accuracy and reliability of volume measurements obtained using three-dimensional (3D) thoracoscopic ultrasound (US) imaging. Artificial 'tumours' were created by injecting a liquid agar mixture into spherical moulds of known volume. Once solidified, the 'tumours' were implanted into the lung tissue in both a porcine lung sample ex vivo and a surgical porcine model in vivo. 3D US images were created by mechanically rotating the thoracoscopic ultrasound probe about its long axis while the transducer was maintained in close contact with the tissue. Volume measurements were made by one observer using the ultrasound images and a manual-radial segmentation technique and these were compared with the known volumes of the agar. In vitro measurements had average accuracy and precision of 4.76% and 1.77%, respectively; in vivo measurements had average accuracy and precision of 8.18% and 1.75%, respectively. The 3D thoracoscopic ultrasound can be used to accurately and reproducibly measure 'tumour' volumes both in vivo and ex vivo.

  17. Hidden measurements, hidden variables and the volume representation of transition probabilities

    OpenAIRE

    Oliynyk, Todd A.

    2005-01-01

    We construct, for any finite dimension $n$, a new hidden measurement model for quantum mechanics based on representing quantum transition probabilities by the volume of regions in projective Hilbert space. For $n=2$ our model is equivalent to the Aerts sphere model and serves as a generalization of it for dimensions $n \\geq 3$. We also show how to construct a hidden variables scheme based on hidden measurements and we discuss how joint distributions arise in our hidden variables scheme and th...

  18. Design parameters and source terms: Volume 3, Source terms

    International Nuclear Information System (INIS)

    1987-10-01

    The Design Parameters and Source Terms Document was prepared in accordance with DOE request and to provide data for the environmental impact study to be performed in the future for the Deaf Smith County, Texas site for a nuclear waste repository in salt. This document updates a previous unpublished report by Stearns Catalytic Corporation (SCC), entitled ''Design Parameters and Source Terms for a Two-Phase Repository in Salt,'' 1985, to the level of the Site Characterization Plan - Conceptual Design Report. The previous unpublished SCC Study identifies the data needs for the Environmental Assessment effort for seven possible Salt Repository sites. 11 refs., 9 tabs

  19. Revisiting the returns-volume relationship: Time variation, alternative measures and the financial crisis

    Science.gov (United States)

    Cook, Steve; Watson, Duncan

    2017-03-01

    Following its introduction in the seminal study of Osborne (1959), a voluminous literature has emerged examining the returns-volume relationship for financial assets. The present paper revisits this relationship in an examination of the FTSE100 which extends the existing literature in two ways. First, alternative daily measures of the FTSE100 index are used to create differing returns and absolute returns series to employ in an examination of returns-volume causality. Second, rolling regression analysis is utilised to explore potential time variation in the returns-volume relationship. The findings obtained depict a hitherto unconsidered complexity in this relationship with the type of returns series considered and financial crisis found to be significant underlying factors. The implications of the newly derived results for both the understanding of the nature of the returns-volume relationship and the development of theories in connection to it are discussed.

  20. Orphan Sources and Fresh Fallout: Virtual Exercise in Mobile Measurement (ORPEX)

    International Nuclear Information System (INIS)

    Dowdall, M.; Smethurst, M.A.; Andersson, K.; Aage, H.K.; Palsson, S.E.

    2011-10-01

    In recent years carborne gamma spectrometry has expanded from its role as a geological survey platform to serving as a useful asset in the field of emergency response to radiological and nuclear situations. Its two main applications are searching for orphan sources and for surveying in the aftermath of an accident involving the release of radioactive materials. Despite this expansion, the opportunities for gaining practical experience in the field are limited by cost considerations and practicability. These limitations are exacerbated by the fact that data generated and displayed in the field differ significantly from gamma spectral data generated in a laboratory environment. As a means of exercising existing emergency measuring/surveying capability and introducing carborne measurements to a larger group, a virtual exercise was devised. The exercise ORPEX (Orphan Sources and Fresh Fallout Virtual Exercise in Mobile Measurement) featured two typical emergency scenarios in which carborne measuring systems might be deployed: firstly a search for multiple orphan sources and secondly surveying to delineate patchy fallout from a local release point. In the first scenario, synthetic spectral data were generated for imaginary point sources and inserted into genuine carborne measurements from in the Trondheim area of Norway. Participants were presented with a typical software tool and data in a range of typical formats and asked to report the source locations and isotopes within a time limit. In the second scenario, synthetic spectral data representing fallout from a local fire involving radioactive material were added to real carborne data from the Trondheim area. Participants were asked to produce maps that identify and characterise the regions of contamination within the same time limit. Fourteen individual organisations from seven different countries supplied results. Results from participants indicate that for strong sources of isotopes with simple spectra featuring

  1. Orphan Sources and Fresh Fallout: Virtual Exercise in Mobile Measurement (ORPEX)

    Energy Technology Data Exchange (ETDEWEB)

    Dowdall, M. (Norwegian Radiation Protection Authority, OEsteraas (Norway)); Smethurst, M.A. (Univ. of Exeter and Avalonia Geophysics, Cornwall Campus, Penryn (United Kingdom)); Andersson, K. (Technical Univ. of Denmark. Risoe National Lab. for Sustainable Energy, Roskilde (Denmark)); Aage, H.K. (Danish Emergency Management Agency, Birkeroed (Denmark)); Palsson, S.E. (Icelandic Radiation Protection Institute, Reykjavik (Iceland))

    2011-10-15

    In recent years carborne gamma spectrometry has expanded from its role as a geological survey platform to serving as a useful asset in the field of emergency response to radiological and nuclear situations. Its two main applications are searching for orphan sources and for surveying in the aftermath of an accident involving the release of radioactive materials. Despite this expansion, the opportunities for gaining practical experience in the field are limited by cost considerations and practicability. These limitations are exacerbated by the fact that data generated and displayed in the field differ significantly from gamma spectral data generated in a laboratory environment. As a means of exercising existing emergency measuring/surveying capability and introducing carborne measurements to a larger group, a virtual exercise was devised. The exercise ORPEX (Orphan Sources and Fresh Fallout Virtual Exercise in Mobile Measurement) featured two typical emergency scenarios in which carborne measuring systems might be deployed: firstly a search for multiple orphan sources and secondly surveying to delineate patchy fallout from a local release point. In the first scenario, synthetic spectral data were generated for imaginary point sources and inserted into genuine carborne measurements from in the Trondheim area of Norway. Participants were presented with a typical software tool and data in a range of typical formats and asked to report the source locations and isotopes within a time limit. In the second scenario, synthetic spectral data representing fallout from a local fire involving radioactive material were added to real carborne data from the Trondheim area. Participants were asked to produce maps that identify and characterise the regions of contamination within the same time limit. Fourteen individual organisations from seven different countries supplied results. Results from participants indicate that for strong sources of isotopes with simple spectra featuring

  2. On-line measurement of microwave power in ECR ion source

    International Nuclear Information System (INIS)

    Zhou Changgeng; Kang Wu; Hu Yonghong; Li Yan; Lou Benchao; Zu Xiulan; Xiong Riheng; Chen Junguang; Li Xiaoyun

    2005-01-01

    It is a new technology to apply an ECR ion source to the neutron generator. Because of the structure limitation, working state of the ECR ion source could not be judged by the color of gas discharging in discharge chamber. Therefore, it was hard to estimate if the ECR ion source was working properly in the neutron generator. The method to resolve the problem was described in this paper. The microwave power was measured on-line by a directional coupler and a small microwave power meter. The ion beam current could be educed from the measured incidence microwave power, and discharge state in discharge chamber could be determined. (authors)

  3. Preparation of protactinium measurement source by electroplating method

    International Nuclear Information System (INIS)

    Li Zongwei; Yang Weifan; Fang Keming; Yuan Shuanggui; Guo Junsheng; Pan Qiangyan

    1998-01-01

    An electroplating method for the preparation of Pa sources is described, and the main factors (such as pH value of solution, electroplating time and current density) influencing the electroplating of Pa are tested and discussed with 233 Pa as a tracer. A thin and uniform electroplating Pa-Layer of 1 mg/cm 2 thick on thin stainless steel disk was obtained. The Pa source was measured by a HPGe detector to determine the chemical efficiency

  4. Evaluating measurements of carbon dioxide emissions using a precision source--A natural gas burner.

    Science.gov (United States)

    Bryant, Rodney; Bundy, Matthew; Zong, Ruowen

    2015-07-01

    A natural gas burner has been used as a precise and accurate source for generating large quantities of carbon dioxide (CO2) to evaluate emissions measurements at near-industrial scale. Two methods for determining carbon dioxide emissions from stationary sources are considered here: predicting emissions based on fuel consumption measurements-predicted emissions measurements, and direct measurement of emissions quantities in the flue gas-direct emissions measurements. Uncertainty for the predicted emissions measurement was estimated at less than 1%. Uncertainty estimates for the direct emissions measurement of carbon dioxide were on the order of ±4%. The relative difference between the direct emissions measurements and the predicted emissions measurements was within the range of the measurement uncertainty, therefore demonstrating good agreement. The study demonstrates how independent methods are used to validate source emissions measurements, while also demonstrating how a fire research facility can be used as a precision test-bed to evaluate and improve carbon dioxide emissions measurements from stationary sources. Fossil-fuel-consuming stationary sources such as electric power plants and industrial facilities account for more than half of the CO2 emissions in the United States. Therefore, accurate emissions measurements from these sources are critical for evaluating efforts to reduce greenhouse gas emissions. This study demonstrates how a surrogate for a stationary source, a fire research facility, can be used to evaluate the accuracy of measurements of CO2 emissions.

  5. Volume measurement of thalami in normal Chinese Han nationality adults by the high-resolution MRI

    International Nuclear Information System (INIS)

    Ma Shuai; Chen Nan; Guo Yulin

    2012-01-01

    Objective: To measure the volume of thalamus in 1000 healthy Chinese Han nationality adults, and to analyze the relationship between thalamic volume and age, sex, weight and cerebral volume, to provide reliable data for the construction of database of Chinese adults' digital standard brain. Methods: Totally 1000 healthy Chinese adults of Han nationality aged from 18 to 80 years were recruited.They were divided into 5 groups by age: 18-30, 31-40, 41-50, 51-60 and 61-80 years. Each group included 100 males and 100 females. Brain images were obtained on a 1.5 T MR, and the outline of thalami was drawn with Aquariusws software. Then the thalamic volume was calculated automatically. The volumes of left and right thalamus were compared by paired sample t-test. Thalamic volumes of the same side were compared between males and females by independent sample t-test. And thalamic volumes of different age groups were compared by one-way ANOVA. The relationships between thalamic volume and age, sex, weight and cerebral volume were analyzed respectively. Results: The males' standardized volumes of left and right thalamus of healthy Chinese Han nationality adults were (5776 ± 780), (5655 ± 759) mm 3 , and they were (5464 ±573), (5360 ± 542) mm 3 for female. The males' thalamic volume was more than the females' on the same side (t=2.245, 2.200, P<0.01). The left thalamic volumes of various age groups were (6180 ± 534), (6047 ± 562), (5426 ± 471), (5552 ± 526), (4866 ± 552) mm 3 , respectively, while the right thalamic volumes of the 5 groups were (6069 ± 532), (5895 ± 539), (5357 ± 480), (5396 ± 445),(4791 ± 558)mm 3 , respectively. There were statistically significant difference among the 5 groups (F=165.686, 165.235, P<0.01). The left and right thalamic volume were all negatively correlated with age (r=-0.633, -0.645, P<0.05). Conclusions: With high resolution 1.5 T MR scanner,grey matter and white matter can be depicted clearly and the outline

  6. Test to Extract Soil Properties Using the Seismic HammerTM Active Seismic Source

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Rebekah F. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Abbott, Robert E. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2017-08-01

    Geologic material properties are necessary parameters for ground motion modeling and are difficult and expensive to obtain via traditional methods. Alternative methods to estimate soil properties require a measurement of the ground's response to a force. A possible method of obtaining these measurements is active-source seismic surveys, but measurements of the ground response at the source must also be available. The potential of seismic sources to obtain soil properties is limited, however, by the repeatability of the source. Explosives, and hammer surveys are not repeatable because of variable ground coupling or swing strength. On the other hand, the Seismic Hammer TM (SH) is consistent in the amount of energy it inputs into the ground. In addition, it leaves large physical depressions as a result of ground compaction. The volume of ground compaction varies by location. Here, we hypothesize that physical depressions left in the earth by the SH correlate to energy recorded by nearby geophones, and therefore are a measurement of soil physical properties. Using measurements of the volume of shot holes, we compare the spatial distribution of the volume of ground compacted between the different shot locations. We then examine energy recorded by the nearest 50 geophones and compare the change in amplitude across hits at the same location. Finally, we use the percent difference between the energy recorded by the first and later hits at a location to test for a correlation to the volume of the shot depressions. We find that: * Ground compaction at the shot-depression does cluster geographically, but does not correlate to known surface features. * Energy recorded by nearby geophones reflects ground refusal after several hits. * There is no correlation to shot volume and changes in energy at particular shot locations. Deeper material properties (i.e. below the depth of surface compaction) may be contributing to the changes in energy propagation. * Without further

  7. A new approach for calculation of volume confined by ECR surface and its area in ECR ion source

    International Nuclear Information System (INIS)

    Filippov, A.V.

    2007-01-01

    The volume confined by the resonance surface and its area are important parameters of the balance equations model for calculation of ion charge-state distribution (CSD) in the electron-cyclotron resonance (ECR) ion source. A new approach for calculation of these parameters is given. This approach allows one to reduce the number of parameters in the balance equations model

  8. Technical Note: Stored grain volume measurement using a low density point cloud

    Science.gov (United States)

    The mass of stored grain is often determined from volume measurements by crop insurers, government auditors, and stored grain managers conducting inventories. Recent increases in bin size have accentuated the difficulty of accounting for irregularities and variations in surface conditions in calcula...

  9. High spatiotemporal resolution measurement of regional lung air volumes from 2D phase contrast x-ray images.

    Science.gov (United States)

    Leong, Andrew F T; Fouras, Andreas; Islam, M Sirajul; Wallace, Megan J; Hooper, Stuart B; Kitchen, Marcus J

    2013-04-01

    Described herein is a new technique for measuring regional lung air volumes from two-dimensional propagation-based phase contrast x-ray (PBI) images at very high spatial and temporal resolution. Phase contrast dramatically increases lung visibility and the outlined volumetric reconstruction technique quantifies dynamic changes in respiratory function. These methods can be used for assessing pulmonary disease and injury and for optimizing mechanical ventilation techniques for preterm infants using animal models. The volumetric reconstruction combines the algorithms of temporal subtraction and single image phase retrieval (SIPR) to isolate the image of the lungs from the thoracic cage in order to measure regional lung air volumes. The SIPR algorithm was used to recover the change in projected thickness of the lungs on a pixel-by-pixel basis (pixel dimensions ≈ 16.2 μm). The technique has been validated using numerical simulation and compared results of measuring regional lung air volumes with and without the use of temporal subtraction for removing the thoracic cage. To test this approach, a series of PBI images of newborn rabbit pups mechanically ventilated at different frequencies was employed. Regional lung air volumes measured from PBI images of newborn rabbit pups showed on average an improvement of at least 20% in 16% of pixels within the lungs in comparison to that measured without the use of temporal subtraction. The majority of pixels that showed an improvement was found to be in regions occupied by bone. Applying the volumetric technique to sequences of PBI images of newborn rabbit pups, it is shown that lung aeration at birth can be highly heterogeneous. This paper presents an image segmentation technique based on temporal subtraction that has successfully been used to isolate the lungs from PBI chest images, allowing the change in lung air volume to be measured over regions as small as the pixel size. Using this technique, it is possible to measure

  10. Demonstration of an automated electromanometer for measurement of solution volume in accountability vessels

    International Nuclear Information System (INIS)

    Suda, S.; Keisch, B.; Hayashi, M.; Onuma, T.; Fukuari, Y.

    1981-09-01

    A system for measuring the liquid volume in input and plutonium product accountability vessels, based upon a desktop-computer-controlled electromanometer, was installed at the Tokai-Mura reprocessing plant. In-tank temperatures, pressure measurements relating to volume and density, and load-cell weights are measured cyclically and recorded. The system feasibility was demonstrated through a series of tests including vessel calibration and the effects of thermal expansion, and through use during thirteen months of on-line plant operation. The value to the operator of the recording, display, replay, data handling, and report generation features of the system was demonstrated as was the enhanced precision of the electromanometer as compared to the conventional water-filled manometer system. The automated electromanometer system consists of a pneumatic scanner, a precision electromanometer, electronic scanner, a digital voltmeter, and a desktop computer with disc and tape mass storage, cathode-ray tube (CRT) graphics display, and printer output. The desktop computer is used to control the pneumatic and electronic scanners and the digital voltmeter and to log in the measurement data

  11. Measurement of regional pulmonary blood volume in patients with increased pulmonary blood flow or pulmonary arterial hypertension

    International Nuclear Information System (INIS)

    Wollmer, P.; Rozcovek, A.; Rhodes, C.G.; Allan, R.M.; Maseri, A.

    1984-01-01

    The effects of chronic increase in pulmonary blood flow and chronic pulmonary hypertension on regional pulmonary blood volume was measured in two groups of patients. One group of patients had intracardiac, left-to-right shunts without appreciable pulmonary hypertension, and the other consisted of patients with Eisenmenger's syndrome or primary pulmonary hypertension, i.e. patients with normal or reduced blood flow and severe pulmonary hypertension. A technique based on positron tomography was used to measure lung density (by transmission scanning) and regional pulmonary blood volume (after inhalation of /sup 11/CO). The distribution of pulmonary blood volume was more uniform in patients with chronic increase in pulmonary blood flow than in normal subjects. There were also indications of an absolute increase in intrapulmonary blood volume by about 15%. In patients with chronic pulmonary arterial hypertension, the distribution of pulmonary blood volume was also abnormally uniform. There was, however, no indication that overall intrapulmonary blood volume was substantially different from normal subjects. The abnormally uniform distribution of pulmonary blood volume can be explained by recruitment and/or dilatation of vascular beds. Intrapulmonary blood volume appears to be increased in patients with intracardiac, left-to-right shunts. With the development of pulmonary hypertension, intrapulmonary blood volume falls, which may be explained by reactive changes in the vasculature and/or obliteration of capillaries

  12. Documentation for grants equal to tax model: Volume 3, Source code

    International Nuclear Information System (INIS)

    Boryczka, M.K.

    1986-01-01

    The GETT model is capable of forecasting the amount of tax liability associated with all property owned and all activities undertaken by the US Department of Energy (DOE) in site characterization and repository development. The GETT program is a user-friendly, menu-driven model developed using dBASE III/trademark/, a relational data base management system. The data base for GETT consists primarily of eight separate dBASE III/trademark/ files corresponding to each of the eight taxes (real property, personal property, corporate income, franchise, sales, use, severance, and excise) levied by State and local jurisdictions on business property and activity. Additional smaller files help to control model inputs and reporting options. Volume 3 of the GETT model documentation is the source code. The code is arranged primarily by the eight tax types. Other code files include those for JURISDICTION, SIMULATION, VALIDATION, TAXES, CHANGES, REPORTS, GILOT, and GETT. The code has been verified through hand calculations

  13. Proper Measurement of the Prostate Volume by Transrectal Ultrasound: Experimental Study about the Prostate with Focal Intravesical Protrusion of the Enlarged Central Gland

    Energy Technology Data Exchange (ETDEWEB)

    Moon, Sung Kyoung; Kim, Hyoung Jung; Lim, Joo Won; Lee, Dong Ho; Ko, Young Tae [Kyung Hee University Hospital, Seoul (Korea, Republic of)

    2008-06-15

    To evaluate the proper volume measurement of prostate with focal intravesical protrusion of enlarged central gland by comparison between methods using craniocaudal length from top of protruded central gland and from prostate base near bladder neck to prostate apex. We made 20 prostate models with focal intravesical protrusion (volume range: 20{approx}50 mL, height of protrusion: about 1 cm) using devil's tongue jelly. Two radiologists measured volume of models 3 times by two kinds of methods using craniocaudal length from top of protruded central gland (method 1) and from prostate base near bladder neck (method 2) by transrectal ultrasound. The accuracy of volume measurement of models was evaluated statistically by comparing their average volume to true volume. Intra- and interobserver agreement was also evaluated. Average true volume of models was 31.05 mL. Each average volume using method 1 by two observers was 37.07 mL and 38.56 mL. Each average volume using method 2 was 30.69 mL and 31.55 mL. Volume measurement using method 2 was approximated to true volume of prostate statistically (p = .654, .823). There was no significant inter- and intra-observer variation in both methods. To measure the accurate volume of prostate with focal intravesical protrusion of enlarged central gland, its craniocaudal length should be measured from prostate base near bladder neck

  14. A contact-free volumetric measurement of facial volume after third molar osteotomy: proof of concept.

    Science.gov (United States)

    Brüllmann, Dan; Jürchott, Lena Marie; John, Christoph; Trempler, Christina; Schwanecke, Ulrich; Schulze, Ralf K W

    2014-01-01

    The present study tested the reliability of an optical scanning device for the objective assessment of postoperative facial swelling. Twenty control subjects bearing a defined volume of water (10-30 mL) in an intraorally carried balloon were tested to assess the measurement accuracy of the device. As a proof of concept, facial volumes of 59 surgical cases were recorded before osteotomy and 1 and 7 days after intervention with the use of a structured light scanner. The median difference between the applied and the measured volumes was 0.67 mL for the control test with the artificial swelling simulated using water balloons. For subjects having third molar osteotomy, extraoral volume increased to 5.29 cm(3) 1 day after surgery (95% CI 5.22-8.52) and decreased to 0.00 mL (95% CI 0.85-2.55) after 7 days. Contact-free visible-light 3-dimensional scanning is reliable for the objective assessment of postoperative facial swelling. Copyright © 2014 Elsevier Inc. All rights reserved.

  15. Measuring hydrophobic micropore volumes in geosorbents from trichloroethylene desorption data.

    Science.gov (United States)

    Cheng, Hefa; Reinhard, Martin

    2006-06-01

    Hydrophobic micropores can play a significant role in controlling the long-term release of organic contaminants from geosorbents. We describe a technique for quantifying the total and the hydrophobic mineral micropore volumes based on the mass of trichloroethylene (TCE) sorbed in the slow-releasing pores under dry and wet conditions, respectively. Micropore desorption models were used to differentiate the fast- and slow-desorbing fractions in desorption profiles. The micropore environment in which organic molecules were sorbed in the presence of water was probed by studying the transformation of a water-reactive compound (2,2-dichloropropane or 2,2-DCP). For sediment from an alluvial aquifer, the total and hydrophobic micropore volumes estimated using this technique were 4.65 microL/g and 0.027 microL/g (0.58% of total), respectively. In microporous silica gel A, a hydrophobic micropore volume of 0.038 microL/g (0.035% of reported total) was measured. The dehydrohalogenation rate of 2,2-DCP sorbed in hydrophobic micropores of the sediment was slower than that reported in bulk water, indicating an environment of low water activity. The results suggest that hydrolyzable organic contaminants sorbed in hydrophobic micropores react slower than in bulk water, consistent with the reported persistence of reactive contaminants in natural soils.

  16. CT- and MRI-based volumetry of resected liver specimen: Comparison to intraoperative volume and weight measurements and calculation of conversion factors

    International Nuclear Information System (INIS)

    Karlo, C.; Reiner, C.S.; Stolzmann, P.; Breitenstein, S.; Marincek, B.; Weishaupt, D.; Frauenfelder, T.

    2010-01-01

    Objective: To compare virtual volume to intraoperative volume and weight measurements of resected liver specimen and calculate appropriate conversion factors to reach better correlation. Methods: Preoperative (CT-group, n = 30; MRI-group, n = 30) and postoperative MRI (n = 60) imaging was performed in 60 patients undergoing partial liver resection. Intraoperative volume and weight of the resected liver specimen was measured. Virtual volume measurements were performed by two readers (R1,R2) using dedicated software. Conversion factors were calculated. Results: Mean intraoperative resection weight/volume: CT: 855 g/852 mL; MRI: 872 g/860 mL. Virtual resection volume: CT: 960 mL(R1), 982 mL(R2); MRI: 1112 mL(R1), 1115 mL(R2). Strong positive correlation for both readers between intraoperative and virtual measurements, mean of both readers: CT: R = 0.88(volume), R = 0.89(weight); MRI: R = 0.95(volume), R = 0.92(weight). Conversion factors: 0.85(CT), 0.78(MRI). Conclusion: CT- or MRI-based volumetry of resected liver specimen is accurate and recommended for preoperative planning. A conversion of the result is necessary to improve intraoperative and virtual measurement correlation. We found 0.85 for CT- and 0.78 for MRI-based volumetry the most appropriate conversion factors.

  17. Length and volume of morphologically normal kidneys in Korean Children: Ultrasound measurement and estimation using body size

    International Nuclear Information System (INIS)

    Kim, Jun Hwee; Kim, Myung Joon; Lim, Sok Hwan; Lee, Mi Jung; Kim, Ji Eun

    2013-01-01

    To evaluate the relationship between anthropometric measurements and renal length and volume measured with ultrasound in Korean children who have morphologically normal kidneys, and to create simple equations to estimate the renal sizes using the anthropometric measurements. We examined 794 Korean children under 18 years of age including a total of 394 boys and 400 girls without renal problems. The maximum renal length (L) (cm), orthogonal anterior-posterior diameter (D) (cm) and width (W) (cm) of each kidney were measured on ultrasound. Kidney volume was calculated as 0.523 x L x D x W (cm 3 ). Anthropometric indices including height (cm), weight (kg) and body mass index (m 2 /kg) were collected through a medical record review. We used linear regression analysis to create simple equations to estimate the renal length and the volume with those anthropometric indices that were mostly correlated with the US-measured renal sizes. Renal length showed the strongest significant correlation with patient height (R2, 0.874 and 0.875 for the right and left kidneys, respectively, p < 0.001). Renal volume showed the strongest significant correlation with patient weight (R2, 0.842 and 0.854 for the right and left kidneys, respectively, p < 0.001). The following equations were developed to describe these relationships with an estimated 95% range of renal length and volume (R2, 0.826-0.884, p < 0.001): renal length = 2.383 + 0.045 x Height (± 1.135) and = 2.374 + 0.047 x Height (± 1.173) for the right and left kidneys, respectively; and renal volume 7.941 + 1.246 x Weight (± 15.920) and = 7.303 + 1.532 x Weight (± 18.704) for the right and left kidneys, respectively. Scatter plots between height and renal length and between weight and renal volume have been established from Korean children and simple equations between them have been developed for use in clinical practice.

  18. Length and volume of morphologically normal kidneys in Korean Children: Ultrasound measurement and estimation using body size

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jun Hwee; Kim, Myung Joon; Lim, Sok Hwan; Lee, Mi Jung [Dept. of Radiology and Research Institute of Radiological Science, Severance Children' s Hospital, Yonsei University College of Medicine, Seoul (Korea, Republic of); Kim, Ji Eun [Biostatistics Collaboration Unit, Yonsei University College of Medicine, Seoul (Korea, Republic of)

    2013-08-15

    To evaluate the relationship between anthropometric measurements and renal length and volume measured with ultrasound in Korean children who have morphologically normal kidneys, and to create simple equations to estimate the renal sizes using the anthropometric measurements. We examined 794 Korean children under 18 years of age including a total of 394 boys and 400 girls without renal problems. The maximum renal length (L) (cm), orthogonal anterior-posterior diameter (D) (cm) and width (W) (cm) of each kidney were measured on ultrasound. Kidney volume was calculated as 0.523 x L x D x W (cm{sup 3}). Anthropometric indices including height (cm), weight (kg) and body mass index (m{sup 2}/kg) were collected through a medical record review. We used linear regression analysis to create simple equations to estimate the renal length and the volume with those anthropometric indices that were mostly correlated with the US-measured renal sizes. Renal length showed the strongest significant correlation with patient height (R2, 0.874 and 0.875 for the right and left kidneys, respectively, p < 0.001). Renal volume showed the strongest significant correlation with patient weight (R2, 0.842 and 0.854 for the right and left kidneys, respectively, p < 0.001). The following equations were developed to describe these relationships with an estimated 95% range of renal length and volume (R2, 0.826-0.884, p < 0.001): renal length = 2.383 + 0.045 x Height (± 1.135) and = 2.374 + 0.047 x Height (± 1.173) for the right and left kidneys, respectively; and renal volume 7.941 + 1.246 x Weight (± 15.920) and = 7.303 + 1.532 x Weight (± 18.704) for the right and left kidneys, respectively. Scatter plots between height and renal length and between weight and renal volume have been established from Korean children and simple equations between them have been developed for use in clinical practice.

  19. The Development of a Flexible Measuring System for Muscle Volume Using Ultrasonography

    Science.gov (United States)

    Fukumoto, Kiyotaka; Fukuda, Osamu; Tsubai, Masayoshi; Muraki, Satoshi

    Quantification of muscle volume can be used as a means for the estimation of muscle strength. Its measuring process does not need the subject's muscular contractions so it is completely safe and particularly suited for elderly people. Therefore, we have developed a flexible measuring system for muscle volume using ultrasonography. In this system, an ultrasound probe is installed on a link mechanism which continuously scans fragmental images along the human body surface. These images are then measured and composed into a wide area cross-sectional image based on the spatial compounding method. The flexibility of the link mechanism enables the operator to measure the images under any body postures and body site. The spatial compounding method significantly reduces speckle and artifact noises from the composed cross-sectional image so that the operator can observe the individual muscles, such as Rectus femoris, Vastus intermedius, and so on, in detail. We conducted the experiments in order to examine the advantages of this system we have developed. The experimental results showed a high accuracy of the measuring position which was calculated using the link mechanism and presented the noise reduction effect based on the spatial compounding method. Finally, we confirmed high correlations between the MRI images and the ones of the developed system to verify the validity of the system.

  20. Methane source identification in Boston, Massachusetts using isotopic and ethane measurements

    Science.gov (United States)

    Down, A.; Jackson, R. B.; Plata, D.; McKain, K.; Wofsy, S. C.; Rella, C.; Crosson, E.; Phillips, N. G.

    2012-12-01

    Methane has substantial greenhouse warming potential and is the principle component of natural gas. Fugitive natural gas emissions could be a significant source of methane to the atmosphere. However, the cumulative magnitude of natural gas leaks is not yet well constrained. We used a combination of point source measurements and ambient monitoring to characterize the methane sources in the Boston urban area. We developed distinct fingerprints for natural gas and multiple biogenic methane sources based on hydrocarbon concentration and isotopic composition. We combine these data with periodic measurements of atmospheric methane and ethane concentration to estimate the fractional contribution of natural gas and biogenic methane sources to the cumulative urban methane flux in Boston. These results are used to inform an inverse model of urban methane concentration and emissions.

  1. Relations between various measures of iodine intake and thyroid volume, thyroid nodularity, and serum thyroglobulin

    DEFF Research Database (Denmark)

    Rasmussen, Lone Banke; Ovesen, L.; Bulow, I.

    2002-01-01

    sought to identify, if possible, groups at risk of thyroid disease because of their food choices. Design: This cohort study included 4649 randomly selected subjects with mild-to-moderate iodine deficiency; the subjects lived in 2 cities in Denmark. Iodine intake was estimated by using a food...... some measures of iodine intake were significantly related to the prevalence of thyroid nodules. Conclusions: Even in a geographic area where mild iodine deficiency is common, a significant relation between iodine intake and thyroid volume was found. All measures of iodine intake, except iodine......Background: Iodine intake can be measured in various ways, and each method may have advantages and disadvantages. Objective: We sought to investigate the potential associations of various measures of iodine intake with thyroid volume, prevalence of thyroid nodules, and serum thyroglobulin. We also...

  2. Feasibility of efficient room-temperature solid-state sources of indistinguishable single photons using ultrasmall mode volume cavities

    Science.gov (United States)

    Wein, Stephen; Lauk, Nikolai; Ghobadi, Roohollah; Simon, Christoph

    2018-05-01

    Highly efficient sources of indistinguishable single photons that can operate at room temperature would be very beneficial for many applications in quantum technology. We show that the implementation of such sources is a realistic goal using solid-state emitters and ultrasmall mode volume cavities. We derive and analyze an expression for photon indistinguishability that accounts for relevant detrimental effects, such as plasmon-induced quenching and pure dephasing. We then provide the general cavity and emitter conditions required to achieve efficient indistinguishable photon emission and also discuss constraints due to phonon sideband emission. Using these conditions, we propose that a nanodiamond negatively charged silicon-vacancy center combined with a plasmonic-Fabry-Pérot hybrid cavity is an excellent candidate system.

  3. Clinical evaluation of preoperative measurement of liver volume by CT volumetry

    International Nuclear Information System (INIS)

    Takahashi, Masahiro; Sasaki, Ryoko; Kato, Kenichi

    2003-01-01

    The utility of measuring liver volume by CT volumetry prior to hepatectomy for treatment of hepatobiliary diseases was assessed by investigating the relationship between liver volume and perioperative hepatic function, and some perioperative factors. Both residual liver volume (RLV) and functional residual liver volume rate (%FRLV) had a significant negative correlation with maximum postoperative total bilirubin (T. Bil) (r=-0.318, r=-0.477, respectively). Further, RLV and %FRLV exhibited a negative correlation with length of intensive care unit (ICU) stay (r=-0.297, r=-0.397, respectively). The ratio of patients with maximum postoperative T. Bil≥10 mg/dl among patients with RLV<500 ml was significantly higher than that among patients with RLV≥500 ml (p<0.05). Similarly, the ratio of patients with maximum postoperative T. Bil≥10 mg/dl among patients with %FRLV<40% was significantly higher than that among patients with %FRLV≥40% (p<0.05). Among patients with %FRLV<40%, maximum T. Bil for patients who underwent portal vein embolization (PVE) was significantly lower than that for patients who did not undergo PVE (p<0.05). When performing hepatectomy, the risk of severe postoperative liver failure is low as long as %FRLV and RLV are above 40% and 500 ml, respectively, and PVE is useful for performing extended hepatectomy when %FRLV is <40%. (author)

  4. Three-dimensional echocardiography: assessment of inter- and intra-operator variability and accuracy in the measurement of left ventricular cavity volume and myocardial mass

    International Nuclear Information System (INIS)

    Nadkarni, S.K.; Drangova, M.; Boughner, D.R.; Fenster, A.; Department of Medical Biophysics, Medical Sciences Building, University of Western Ontario, London, Ontario N6A 5C1

    2000-01-01

    Accurate left ventricular (LV) volume and mass estimation is a strong predictor of cardiovascular morbidity and mortality. We propose that our technique of 3D echocardiography provides an accurate quantification of LV volume and mass by the reconstruction of 2D images into 3D volumes, thus avoiding the need for geometric assumptions. We compared the accuracy and variability in LV volume and mass measurement using 3D echocardiography with 2D echocardiography, using in vitro studies. Six operators measured the LV volume and mass of seven porcine hearts, using both 3D and 2D techniques. Regression analysis was used to test the accuracy of results and an ANOVA test was used to compute variability in measurement. LV volume measurement accuracy was 9.8% (3D) and 18.4% (2D); LV mass measurement accuracy was 5% (3D) and 9.2% (2D). Variability in LV volume quantification with 3D echocardiography was %SEM inter = 13.5%, %SEM intra = 11.4%, and for 2D echocardiography was %SEM inter = 21.5%, %SEM intra = 19.1%. We derived an equation to predict uncertainty in measurement of LV volume and mass using 3D echocardiography, the results of which agreed with our experimental results to within 13%. 3D echocardiography provided twice the accuracy for LV volume and mass measurement and half the variability for LV volume measurement as compared with 2D echocardiography. (author)

  5. Inverse source problems for eddy current equations

    International Nuclear Information System (INIS)

    Rodríguez, Ana Alonso; Valli, Alberto; Camaño, Jessika

    2012-01-01

    We study the inverse source problem for the eddy current approximation of Maxwell equations. As for the full system of Maxwell equations, we show that a volume current source cannot be uniquely identified by knowledge of the tangential components of the electromagnetic fields on the boundary, and we characterize the space of non-radiating sources. On the other hand, we prove that the inverse source problem has a unique solution if the source is supported on the boundary of a subdomain or if it is the sum of a finite number of dipoles. We address the applicability of this result for the localization of brain activity from electroencephalography and magnetoencephalography measurements. (paper)

  6. Distributed 3D Source Localization from 2D DOA Measurements Using Multiple Linear Arrays

    Directory of Open Access Journals (Sweden)

    Antonio Canclini

    2017-01-01

    Full Text Available This manuscript addresses the problem of 3D source localization from direction of arrivals (DOAs in wireless acoustic sensor networks. In this context, multiple sensors measure the DOA of the source, and a central node combines the measurements to yield the source location estimate. Traditional approaches require 3D DOA measurements; that is, each sensor estimates the azimuth and elevation of the source by means of a microphone array, typically in a planar or spherical configuration. The proposed methodology aims at reducing the hardware and computational costs by combining measurements related to 2D DOAs estimated from linear arrays arbitrarily displaced in the 3D space. Each sensor measures the DOA in the plane containing the array and the source. Measurements are then translated into an equivalent planar geometry, in which a set of coplanar equivalent arrays observe the source preserving the original DOAs. This formulation is exploited to define a cost function, whose minimization leads to the source location estimation. An extensive simulation campaign validates the proposed approach and compares its accuracy with state-of-the-art methodologies.

  7. Implementing US Department of Energy lessons learned programs. Volume 2

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-08-01

    The DOE Lessons Learned Handbook is a two-volume publication developed to supplement the DOE Lessons Learned Standard (DOE-STD-7501-95) with information that will organizations in developing or improving their lessons learned programs. Volume 1 includes greater detail than the Standard in areas such as identification and documentation of lessons learned; it also contains sections on specific processes such as training and performance measurement. Volume 2 (this document) contains examples of program documents developed by existing lessons learned programs as well as communications material, functional categories, transmittal documents, sources of professional and industry lessons learned, and frequently asked questions about the Lessons Learned List Service.

  8. Know your tools - concordance of different methods for measuring brain volume change after ischemic stroke

    Energy Technology Data Exchange (ETDEWEB)

    Yassi, Nawaf; Campbell, Bruce C.V.; Davis, Stephen M.; Bivard, Andrew [The University of Melbourne, Departments of Medicine and Neurology, Melbourne Brain Centre rate at The Royal Melbourne Hospital, Parkville, Victoria (Australia); Moffat, Bradford A.; Steward, Christopher; Desmond, Patricia M. [The University of Melbourne, Department of Radiology, The Royal Melbourne Hospital, Parkville (Australia); Churilov, Leonid [The University of Melbourne, The Florey Institute of Neurosciences and Mental Health, Parkville (Australia); Parsons, Mark W. [University of Newcastle and Hunter Medical Research Institute, Priority Research Centre for Translational Neuroscience and Mental Health, Newcastle (Australia)

    2015-07-15

    Longitudinal brain volume changes have been investigated in a number of cerebral disorders as a surrogate marker of clinical outcome. In stroke, unique methodological challenges are posed by dynamic structural changes occurring after onset, particularly those relating to the infarct lesion. We aimed to evaluate agreement between different analysis methods for the measurement of post-stroke brain volume change, and to explore technical challenges inherent to these methods. Fifteen patients with anterior circulation stroke underwent magnetic resonance imaging within 1 week of onset and at 1 and 3 months. Whole-brain as well as grey- and white-matter volume were estimated separately using both an intensity-based and a surface watershed-based algorithm. In the case of the intensity-based algorithm, the analysis was also performed with and without exclusion of the infarct lesion. Due to the effects of peri-infarct edema at the baseline scan, longitudinal volume change was measured as percentage change between the 1 and 3-month scans. Intra-class and concordance correlation coefficients were used to assess agreement between the different analysis methods. Reduced major axis regression was used to inspect the nature of bias between measurements. Overall agreement between methods was modest with strong disagreement between some techniques. Measurements were variably impacted by procedures performed to account for infarct lesions. Improvements in volumetric methods and consensus between methodologies employed in different studies are necessary in order to increase the validity of conclusions derived from post-stroke cerebral volumetric studies. Readers should be aware of the potential impact of different methods on study conclusions. (orig.)

  9. Know your tools - concordance of different methods for measuring brain volume change after ischemic stroke

    International Nuclear Information System (INIS)

    Yassi, Nawaf; Campbell, Bruce C.V.; Davis, Stephen M.; Bivard, Andrew; Moffat, Bradford A.; Steward, Christopher; Desmond, Patricia M.; Churilov, Leonid; Parsons, Mark W.

    2015-01-01

    Longitudinal brain volume changes have been investigated in a number of cerebral disorders as a surrogate marker of clinical outcome. In stroke, unique methodological challenges are posed by dynamic structural changes occurring after onset, particularly those relating to the infarct lesion. We aimed to evaluate agreement between different analysis methods for the measurement of post-stroke brain volume change, and to explore technical challenges inherent to these methods. Fifteen patients with anterior circulation stroke underwent magnetic resonance imaging within 1 week of onset and at 1 and 3 months. Whole-brain as well as grey- and white-matter volume were estimated separately using both an intensity-based and a surface watershed-based algorithm. In the case of the intensity-based algorithm, the analysis was also performed with and without exclusion of the infarct lesion. Due to the effects of peri-infarct edema at the baseline scan, longitudinal volume change was measured as percentage change between the 1 and 3-month scans. Intra-class and concordance correlation coefficients were used to assess agreement between the different analysis methods. Reduced major axis regression was used to inspect the nature of bias between measurements. Overall agreement between methods was modest with strong disagreement between some techniques. Measurements were variably impacted by procedures performed to account for infarct lesions. Improvements in volumetric methods and consensus between methodologies employed in different studies are necessary in order to increase the validity of conclusions derived from post-stroke cerebral volumetric studies. Readers should be aware of the potential impact of different methods on study conclusions. (orig.)

  10. Ion implanted Na22 source for positron lifetime measurements

    International Nuclear Information System (INIS)

    Fluss, M.J.; Smedeskjaer, L.C.

    1979-04-01

    A new positron source-sample fabrication technique, intended for high temperature positron annihilation measurements, was developed. The method makes use of a mass separator to implant pure Na 22 into the sample surface. The application of this technique to Cu is described. A brief discussion of the origin of the source component is given, and different possibilities of correcting for it are pointed out. 3 references

  11. Total luminous flux measurement for flexible surface sources with an integrating sphere photometer

    International Nuclear Information System (INIS)

    Yu, Hsueh-Ling; Liu, Wen-Chun

    2014-01-01

    Applying an integrating sphere photometer for total luminous flux measurement is a widely used method. However, the measurement accuracy depends on the spatial uniformity of the integrating sphere, especially when the test sample has a different light distribution from that of the standard source. Therefore, spatial correction is needed to eliminate the effect caused by non-uniformity. To reduce the inconvenience of spatial correction but retain the measurement accuracy, a new type of working standard is designed for flexible and curved surface sources. Applying this new type standard source, the measurement deviation due to different orientations is reduced by an order of magnitude compared with using a naked incandescent lamp as the standard source. (paper)

  12. Automated digital volume measurement of melanoma metastases in sentinel nodes predicts disease recurrence and survival

    DEFF Research Database (Denmark)

    Riber-Hansen, Rikke; Nyengaard, Jens R; Hamilton-Dutoit, Stephen J

    2011-01-01

    statistics (categorical data). In addition, disease-free and melanoma-specific survivals were calculated. Mean metastatic volume per patient was 10.6 mm(3) (median 0.05 mm(3); range 0.0001-621.3 mm(3)) and 9.62 mm(3) (median 0.05 mm(3); range 0.00001-564.3 mm(3)) with manual and digital measurement......, respectively. The Bland-Altman plot showed an even distribution of the differences, and the kappa statistic was 0.84. In multivariate analysis, both manual and digital metastasis volume measurements were independent progression markers when corrected for primary tumour thickness [manual: hazard ratio (HR): 1...

  13. Application of gamma densitometer for measurement of void fraction in liquid hydrogen moderator of HANARO cold neutron source

    International Nuclear Information System (INIS)

    Kim, Myong-Seop; Choi, Jungwoon; Sun, Gwang-Min; Lee, Kye-Hong

    2009-01-01

    The void fraction in the liquid hydrogen used for the moderator of the HANARO cold neutron source (CNS) was measured by using a gamma densitometer technique. A mock-up of the HANARO CNS facility with an electric heating system as the heat source instead of radiations was constructed. The photon transmissions through the hydrogen moderator were simulated to search for an optimum experimental condition. From the simulation, it was confirmed that Am-241 was suitable for the measurement of the void fraction in the liquid hydrogen medium. A gamma densitometer using the Am-241 gamma-ray source was designed and installed at the mock-up of the CNS. The attenuation of 59.5 keV gamma-rays from the Am-241 through the hydrogen medium was measured by using an HPGe detector. The void fraction was determined using the amount of the gamma-ray attenuation. The void fractions in the hydrogen moderator were measured for stable thermo-siphon loops with several electric heat loads applied to the moderator cell of the CNS mock-up. The longitudinal distribution of the void fraction inside the moderator cell was also determined. The void fraction measured at a heat load of 720 W had values of 8-41% depending on the height from the bottom of the moderator cell. The overall void fraction was obtained by volume-weighted averaging of its longitudinal distribution. The void fraction at the nuclear heating power expected at the normal operation condition of the HANARO CNS facility was determined to be about 20%. The large uncertainty was expected in the void fraction determination by a gamma densitometer for the liquid hydrogen medium with the void fraction less than 10%. When the void fraction of the liquid hydrogen was near 20%, the uncertainty in the void fraction determination by using a gamma densitometer became relatively small, and it was regarded as an acceptable level. The measurements for the void fraction will be very useful for the design and operation of the HANARO CNS.

  14. Measurement of the volume growth rate of single budding yeast with the MOSFET-based microfluidic Coulter counter.

    Science.gov (United States)

    Sun, Jiashu; Stowers, Chris C; Boczko, Erik M; Li, Deyu

    2010-11-07

    We report on measurements of the volume growth rate of ten individual budding yeast cells using a recently developed MOSFET-based microfluidic Coulter counter. The MOSFET-based microfluidic Coulter counter is very sensitive, provides signals that are immune from the baseline drift, and can work with cell culture media of complex composition. These desirable features allow us to directly measure the volume growth rate of single cells of Saccharomyces cerevisiae LYH3865 strain budding yeast in YNB culture media over a whole cell cycle. Results indicate that all budding yeast follow a sigmoid volume growth profile with reduced growth rates at the initial stage before the bud emerges and the final stage after the daughter gets mature. Analysis of the data indicates that even though all piecewise linear, Gomperitz, and Hill's function models can fit the global growth profile equally well, the data strongly support local exponential growth phenomenon. Accurate volume growth measurements are important for applications in systems biology where quantitative parameters are required for modeling and simulation.

  15. Evaluation of right ventricular volumes measured by magnetic resonance imaging

    DEFF Research Database (Denmark)

    Møgelvang, J; Stubgaard, M; Thomsen, C

    1988-01-01

    stroke volume was calculated as the difference between end-diastolic and end-systolic volume and compared to left ventricular stroke volume and to stroke volume determined simultaneously by a classical indicator dilution technique. There was good agreement between right ventricular stroke volume......Right ventricular volumes were determined in 12 patients with different levels of right and left ventricular function by magnetic resonance imaging (MRI) using an ECG gated multisection technique in planes perpendicular to the diastolic position of the interventricular septum. Right ventricular...... determined by MRI and by the indicator dilution method and between right and left ventricular stroke volume determined by MRI. Thus, MRI gives reliable values not only for left ventricular volumes, but also for right ventricular volumes. By MRI it is possible to obtain volumes from both ventricles...

  16. Effects of gauge volume on pseudo-strain induced in strain measurement using time-of-flight neutron diffraction

    International Nuclear Information System (INIS)

    Suzuki, Hiroshi; Harjo, Stefanus; Abe, Jun; Xu, Pingguang; Aizawa, Kazuya; Akita, Koichi

    2013-01-01

    Spurious or pseudo-strains observed in time-of-flight (TOF) neutron diffraction due to neutron attenuation, surface-effects and a strain distribution within the gauge volume were investigated. Experiments were carried out on annealed and bent ferritic steel bars to test these effects. The most representative position in the gauge volume corresponds to the neutron-weighted center of gravity (ncog), which takes into account variations in intensity within the gauge volume due to neutron attenuation and/or absence of material in the gauge volume. The average strain in the gauge volume was observed to be weighted towards the ncog position but following an increase in the size of the gauge volume the weighted average strain was changed because of the change in the ncog position when a strain gradient appeared within the gauge volume. On the other hand, typical pseudo-strains, which are well known, did appear in through-surface strain measurements when the gauge volume was incompletely filled by the sample. Tensile pseudo-strains due to the surface-effect increased near the sample surface and exhibited a similar trend regardless of the size of the gauge volume, while the pseudo-strains increased faster for the smaller gauge volume. Furthermore, a pseudo-strain due to a change in the ncog position was observed even when the gauge volume was perfectly filled in the sample, and it increased with an increase in the size of the gauge volume. These pseudo-strains measured were much larger than those simulated by the conventional modeling, whereas they were simulated by taking into account an incident neutron beam divergence additionally in the model. Therefore, the incident divergence of the incident neutron beam must be carefully designed to avoid pseudo-strains in time-of-flight neutron diffractometry

  17. Volume measurement of multiple sclerosis lesions with magnetic resonance images

    International Nuclear Information System (INIS)

    Wicks, D.A.G.; Tofts, P.S.; Miller, D.H.; Du Boulay, G.H.; Feinstein, A.; Harvey, I.; Brenner, R.; McDonald, W.I.; Sacares, R.P.

    1992-01-01

    The ability to visualise multiple sclerosis lesions in vivo with magnetic resonance imaging suggests an important role in monitoring the course of the disease. In order to help the long-term assessment of prospective treatments, a semi-automated technique for measuring lesion volume has been developed to provide a quantitative index of disease progression. Results are presented from a preliminary study with a single patient and compared to measurements taken from lesion outlines traced by a neuroradiologist, two neurologists and a technician. The semi-automated technique achieved a precision of 6% compared to a range of 12-33% for the manual tracing method. It also reduced the human interaction time from at least 60 min to 15 min. (orig.)

  18. Finite element approximation for time-dependent diffusion with measure-valued source

    Czech Academy of Sciences Publication Activity Database

    Seidman, T.; Gobbert, M.; Trott, D.; Kružík, Martin

    2012-01-01

    Roč. 122, č. 4 (2012), s. 709-723 ISSN 0029-599X R&D Projects: GA AV ČR IAA100750802 Institutional support: RVO:67985556 Keywords : measure-valued source * diffusion equation Subject RIV: BA - General Mathematics Impact factor: 1.329, year: 2012 http://library.utia.cas.cz/separaty/2012/MTR/kruzik-finite element approximation for time - dependent diffusion with measure-valued source.pdf

  19. Preoperative MR imaging-based volume measurements of the hippocampal formation and anterior temporal lobe in epileptic patients

    International Nuclear Information System (INIS)

    Jack, C.R.; Sharbrough, F.W.; Twomey, C.; Zinsmeister, A.R.; Cascino, G.D.; Hirschorn, K.A.; Marsh, W.R.

    1989-01-01

    MR-based volume measurements of the anterior temporal lobe and hippocampal formation were performed in 36 patients who subsequently underwent surgery for medically refractory temporal lobe epilepsy. Seizure lateralization was based on standard clinical and electroencephalographic criteria. No surgical pathologic specimens contained structural lesions; epilepsy in these patients was therefore presumably due to mesial sclerosis. The right-minus-left hippocampal formation volume difference was greater than 0 in all 20 patients operated on the left side and less than 0 in all 16 patients operated on the right side. This difference completely separated the two surgical groups, while the same measurement in a group of 35 normal controls fell between the two surgical groups. Measurements of the anterior temporal to be showed a similar trend but incompletely separated controls, right- and left-sided epileptics. These results suggest that in a significant percentage of cases, MR-based volume measurements correctly identify the unilateral hippocampal atrophy that is known to occur in cases of mesial temporal sclerosis

  20. An experimental study on the excitation of large volume airguns in a small volume body of water

    International Nuclear Information System (INIS)

    Wang, Baoshan; Yang, Wei; Yuan, Songyong; Ge, Hongkui; Chen, Yong; Guo, Shijun; Xu, Ping

    2010-01-01

    A large volume airgun array is effective in generating seismic waves, which is extensively used in large volume bodies of water such as oceans, lakes and reservoirs. So far, the application of large volume airguns is subject to the distribution of large volume bodies of water. This paper reports an attempt to utilize large volume airguns in a small body of water as a seismic source for seismotectonic studies. We carried out a field experiment in Mapaoquan pond, Fangshan district, Beijing, during the period 25–30 May 2009. Bolt LL1500 airguns, each with volumes of 2000 in 3 , the largest commercial airguns available today, were used in this experiment. We tested the excitation of the airgun array with one or two guns. The airgun array was placed 7–11 m below the water's surface. The near- and far-field seismic motions induced by the airgun source were recorded by a 100 km long seismic profile composed of 16 portable seismometers and a 100 m long strong motion seismograph profile, respectively. The following conclusions can be drawn from this experiment. First, it is feasible to excite large volume airguns in a small volume body of water. Second, seismic signals from a single shot of one airgun can be recognized at the offset up to 15 km. Taking advantage of high source repeatability, we stacked records from 128 shots to enhance the signal-to-noise ratio, and direct P-waves can be easily identified at the offset ∼50 km in stacked records. Third, no detectable damage to fish or near-field constructions was caused by the airgun shots. Those results suggest that large volume airguns excited in small bodies of water can be used as a routinely operated seismic source for mid-scale (tens of kilometres) subsurface explorations and monitoring under various running conditions

  1. A comparative study of linear measurement of the brain and three-dimensional measurement of brain volume using CT scans

    International Nuclear Information System (INIS)

    Hamano, K.; Iwasaki, N.; Takeya, T.; Takita, H.

    1993-01-01

    Parameters of linear measurement were compared with actual brain volume to assess the significance of linear measurements as indices of atrophy in 31 neurologically normal children and 22 neurologically abnormal children. Brain volume was established by means of an image-analyzing system using contiguous CT scans. The parameters or indices estimated were: (1) the maximum transverse width of both hemispheres, (2) the maximum longitudinal length of both hemispheres, (3) the maximum frontal subarachnoid space, (4) the maximum width of the interhemispheric fissure, (5) the maximum width of the Sylvian fissure, (6) Evans' ratio, (7) the maximum width of the third ventricle, (8) the cella media index, (9) the maximum width of the fourth ventricle. In neurologically normal children, the maximum transverse width of both hemispheres, the maximum longitudinal length of both hemispheres, the maximum width of the interhemispheric fissure and the maximum width of the Sylvian fissure correlated significantly with the combined volume (CV) of both hemipheres and basal ganglia. In particular, the maximum transverse width of both hemispheres and the maximum longitudinal length of both hemispheres had a high correlation. In neurologically abnormal children the maximum transverse width of both hemispheres and the maximum width of the interhemispheric fissure were significantly correlated with the CV of both hemispheres and basal ganglia. (orig.)

  2. Galvanically Decoupled Current Source Modules for Multi-Channel Bioimpedance Measurement Systems

    Directory of Open Access Journals (Sweden)

    Roman Kusche

    2017-10-01

    Full Text Available Bioimpedance measurements have become a useful technique in the past several years in biomedical engineering. Especially, multi-channel measurements facilitate new imaging and patient monitoring techniques. While most instrumentation research has focused on signal acquisition and signal processing, this work proposes the design of an excitation current source module that can be easily implemented in existing or upcoming bioimpedance measurement systems. It is galvanically isolated to enable simultaneous multi-channel bioimpedance measurements with a very low channel-coupling. The system is based on a microcontroller in combination with a voltage-controlled current source circuit. It generates selectable sinusoidal excitation signals between 0.12 and 1.5 mA in a frequency range from 12 to 250 kHz, whereas the voltage compliance range is ±3.2 V. The coupling factor between two current sources, experimentally galvanically connected with each other, is measured to be less than −48 dB over the entire intended frequency range. Finally, suggestions for developments in the future are made.

  3. Measurement of volume and flow in the digestive tract

    International Nuclear Information System (INIS)

    Dixon, R.M.; Kennedy, P.M.; Milligan, L.P.

    1983-01-01

    Measurement of digesta volume and flow in the gastro-intestinal tract of ruminants may be achieved by either of two methods. The first involves total recovery of digesta through a cannula with gravimetric and physical (sieving) analysis. Alternatively, the flow of digesta may be estimated by reference to markers, with digesta samples taken through a T-shaped or re-entral intestinal cannula. The second approach assumes steady nutritional conditions, with the movement of digesta fractions estimated from the disappearance of specific markers. The adequacy of markers currently available for this purpose is discussed. Advantages of complementary techniques are emphasized. (author)

  4. Broadband light source for fiber-optic measurement system in spaceborne applications

    Science.gov (United States)

    Rößner, Max R.; Müller, Mathias S.; Buck, Thorbjörn C.; Koch, Alexander W.

    2012-01-01

    Measuring temperatures, mechanical loads and derived quantities precisely and reliably play an important role in spaceflight. With spacecraft becoming increasingly complex, upscaling of present telemetry techniques can become cumbersome. Additionally, there are entirely new sensory requirements, resulting from emerging technologies such as smart structures, active vibration damping and composite material health monitoring. It has been demonstrated in preceding studies that these measurements can be advantageously and efficiently carried out by means of fiber-optic systems. The most prominent fiber-optic strain and temperature sensor is the fiber Bragg grating. Typically, multiple fiber Bragg gratings are used to translate entire temperature and strain fields into an optical wavelength information. For the interrogation of these sensors, a broadband or scanning light source is required. Additional requirements with respect to the light source are high intensity and unpolarized illumination of the gratings. These constraints can be met by a light source that is based on amplified spontaneous emission in a rare-earth-doped fiber. In the presented work, a compact light source, adapted for measurement applications and targeted towards space applications, has been developed. The design of this light source is presented, as well as its implementation. The light source has been designed and tested for selected core aspects of space robustness and the results of these tests are summarized.

  5. Bayesian source term determination with unknown covariance of measurements

    Science.gov (United States)

    Belal, Alkomiet; Tichý, Ondřej; Šmídl, Václav

    2017-04-01

    Determination of a source term of release of a hazardous material into the atmosphere is a very important task for emergency response. We are concerned with the problem of estimation of the source term in the conventional linear inverse problem, y = Mx, where the relationship between the vector of observations y is described using the source-receptor-sensitivity (SRS) matrix M and the unknown source term x. Since the system is typically ill-conditioned, the problem is recast as an optimization problem minR,B(y - Mx)TR-1(y - Mx) + xTB-1x. The first term minimizes the error of the measurements with covariance matrix R, and the second term is a regularization of the source term. There are different types of regularization arising for different choices of matrices R and B, for example, Tikhonov regularization assumes covariance matrix B as the identity matrix multiplied by scalar parameter. In this contribution, we adopt a Bayesian approach to make inference on the unknown source term x as well as unknown R and B. We assume prior on x to be a Gaussian with zero mean and unknown diagonal covariance matrix B. The covariance matrix of the likelihood R is also unknown. We consider two potential choices of the structure of the matrix R. First is the diagonal matrix and the second is a locally correlated structure using information on topology of the measuring network. Since the inference of the model is intractable, iterative variational Bayes algorithm is used for simultaneous estimation of all model parameters. The practical usefulness of our contribution is demonstrated on an application of the resulting algorithm to real data from the European Tracer Experiment (ETEX). This research is supported by EEA/Norwegian Financial Mechanism under project MSMT-28477/2014 Source-Term Determination of Radionuclide Releases by Inverse Atmospheric Dispersion Modelling (STRADI).

  6. Interactions of glycine betaine with proteins: insights from volume and compressibility measurements.

    Science.gov (United States)

    Shek, Yuen Lai; Chalikian, Tigran V

    2013-01-29

    We report the first application of volume and compressibility measurements to characterization of interactions between cosolvents (osmolytes) and globular proteins. Specifically, we measure the partial molar volumes and adiabatic compressibilities of cytochrome c, ribonuclease A, lysozyme, and ovalbumin in aqueous solutions of the stabilizing osmolyte glycine betaine (GB) at concentrations between 0 and 4 M. The fact that globular proteins do not undergo any conformational transitions in the presence of GB provides an opportunity to study the interactions of GB with proteins in their native states within the entire range of experimentally accessible GB concentrations. We analyze our resulting volumetric data within the framework of a statistical thermodynamic model in which each instance of GB interaction with a protein is viewed as a binding reaction that is accompanied by release of four water molecules. From this analysis, we calculate the association constants, k, as well as changes in volume, ΔV(0), and adiabatic compressibility, ΔK(S0), accompanying each GB-protein association event in an ideal solution. By comparing these parameters with similar characteristics determined for low-molecular weight analogues of proteins, we conclude that there are no significant cooperative effects involved in interactions of GB with any of the proteins studied in this work. We also evaluate the free energies of direct GB-protein interactions. The energetic properties of GB-protein association appear to scale with the size of the protein. For all proteins, the highly favorable change in free energy associated with direct protein-cosolvent interactions is nearly compensated by an unfavorable free energy of cavity formation (excluded volume effect), yielding a modestly unfavorable free energy for the transfer of a protein from water to a GB/water mixture.

  7. Does Height to Width Ratio Correlate with Mean Volume in Gastropods?

    Science.gov (United States)

    Barriga, R.; Seixas, G.; Payne, J.

    2012-12-01

    Marine organisms' shell shape and size show important biological information. For example, shape and size can dictate how the organism ranges for food and escapes predation. Due to lack of data and analysis, the evolution of shell size in marine gastropods (snails) remains poorly known. In this study, I attempt to find the relationship between height to width ratio and mean volume. I collected height and width measurements from primary literature sources and calculated volume from these measurements. My results indicate that there was no correlation between height to width ratio and mean volume between 500 to 200 Ma, but there was a correlation between 200 Ma to present where there is a steady increase in both height to width ratio and mean volume. This means that shell shape was not an important factor at the beginning of gastropod evolution but after 200 Ma body size evolution was increasingly driven by the height to width ratio.

  8. Do energy efficiency measures promote the use of renewable sources?

    International Nuclear Information System (INIS)

    Marques, Antonio C.; Fuinhas, Jose A.

    2011-01-01

    This paper analyses the factors behind the deployment of renewable energy, focusing particularly on the effect of energy efficiency policies and measures. The impact of these factors is appraised within the context of several phases of the use of renewable sources. We therefore apply the quantile regression technique to a set of 21 European Countries in two time spans: from 1990 to 1998, and from 1999 to 2006. We control variables of policy, environment, socioeconomic characteristics, and electricity generation. For the second period, energy efficiency policies and measures concerning renewable sources effectively promote renewables, namely in the take-off phase. We shed light on the lobbying effect of traditional energy industries, showing that it depends both on the period under analysis, and on the kind of traditional energy source.

  9. Ocean Optics Protocols for Satellite Ocean Color Sensor Validation, Revision 4, Volume IV: Inherent Optical Properties: Instruments, Characterizations, Field Measurements and Data Analysis Protocols

    Science.gov (United States)

    Mueller, J. L.; Fargion, G. S.; McClain, C. R. (Editor); Pegau, S.; Zanefeld, J. R. V.; Mitchell, B. G.; Kahru, M.; Wieland, J.; Stramska, M.

    2003-01-01

    This document stipulates protocols for measuring bio-optical and radiometric data for the Sensor Intercomparision and Merger for Biological and Interdisciplinary Oceanic Studies (SIMBIOS) Project activities and algorithm development. The document is organized into 6 separate volumes as Ocean Optics Protocols for Satellite Ocean Color Sensor Validation, Revision 4. Volume I: Introduction, Background, and Conventions; Volume II: Instrument Specifications, Characterization and Calibration; Volume III: Radiometric Measurements and Data Analysis Methods; Volume IV: Inherent Optical Properties: Instruments, Characterization, Field Measurements and Data Analysis Protocols; Volume V: Biogeochemical and Bio-Optical Measurements and Data Analysis Methods; Volume VI: Special Topics in Ocean Optics Protocols and Appendices. The earlier version of Ocean Optics Protocols for Satellite Ocean Color Sensor Validation, Revision 3 is entirely superseded by the six volumes of Revision 4 listed above.

  10. Implementation of 252Cf-source-driven power spectrum density measurement system

    International Nuclear Information System (INIS)

    Ren Yong; Wei Biao; Feng Peng; Li Jiansheng; Ye Cenming

    2012-01-01

    The principle of 252 Cf-source-driven power spectrum density measurement method is introduced. A measurement system and platform is realized accordingly, which is a combination of hardware and software, for measuring nuclear parameters. The detection method of neutron pulses based on an ultra-high-speed data acquisition card (three channels, 1 GHz sampling rate, 1 ns synchronization) is described, and the data processing process and the power spectrum density algorithm on PC are designed. This 252 Cf-source-driven power spectrum density measurement system can effectively obtain the nuclear tag parameters of nuclear random processes, such as correlation function and power spectrum density. (authors)

  11. Two-dimensional particle simulation of negative ion extraction from a volume source

    International Nuclear Information System (INIS)

    Naitou, H.; Fukumasa, O.; Sakachou, K.; Mutou, K.

    1995-01-01

    Two-dimensional electrostatic particle simulation was done to study the extraction of negative ions from a volume plasma source. The simulation model is a rectangular system which consists of an extraction grid, a plasma grid, and a grounded wall. Full dynamics of electrons, ions, and negative ions are followed. Negative ions are extracted from the plasma region to the extraction grid through a slit in the plasma grid. For the lower value of extraction grid potential, the simulation results agree with the Child-Langumuir law, where the extracted negative ion current is proportional to the three-halves power of the potential of the extraction grid. For the higher value of extraction grid potential, the space charge effect of negative ions, which enter into the beamline at the top of the concavity of the positive ion boundary, reduces the negative ion current from the prediction of the Child-Langumuir law. ((orig.))

  12. Simultaneous pressure-volume measurements using optical sensors and MRI for left ventricle function assessment during animal experiment.

    Science.gov (United States)

    Abi-Abdallah Rodriguez, Dima; Durand, Emmanuel; de Rochefort, Ludovic; Boudjemline, Younes; Mousseaux, Elie

    2015-01-01

    Simultaneous pressure and volume measurements enable the extraction of valuable parameters for left ventricle function assessment. Cardiac MR has proven to be the most accurate method for volume estimation. Nonetheless, measuring pressure simultaneously during MRI acquisitions remains a challenge given the magnetic nature of the widely used pressure transducers. In this study we show the feasibility of simultaneous in vivo pressure-volume acquisitions with MRI using optical pressure sensors. Pressure-volume loops were calculated while inducing three inotropic states in a sheep and functional indices were extracted, using single beat loops, to characterize systolic and diastolic performance. Functional indices evolved as expected in response to positive inotropic stimuli. The end-systolic elastance, representing the contractility index, the diastolic myocardium compliance, and the cardiac work efficiency all increased when inducing inotropic state enhancement. The association of MRI and optical pressure sensors within the left ventricle successfully enabled pressure-volume loop analysis after having respective data simultaneously recorded during the experimentation without the need to move the animal between each inotropic state. Copyright © 2014 IPEM. Published by Elsevier Ltd. All rights reserved.

  13. On-line measurement of the microwave power in ECR ion source

    International Nuclear Information System (INIS)

    Zhou Changgeng; Kang Wu; Hu Yonghong; Li Yan; Lou Benchao; Zu Xiulan; Xiong Riheng; Chen Junguang

    2005-01-01

    It is a new technology that ECR ion source is applied in the neutron generator. Because of effect of the structure, working state of ECR ion source could not be judged by the color of gas discharging in discharging chamber as doing in high frequency ion source. Therefore, state adjusting of ECR ion source was difficult in running of the neutron generator. The method to resolve the question is described in this paper. The micro-wave power was measured in case of running by using the method of directional coupler adding small microwave power meter. Because both were in the direct proportion, the ion beam current could be educed from microwave incidence power measured, and discharge state in discharge chamber could be judged. Finally, the neutron generator might be operated in best running state. (authors)

  14. Prediction of the volume flux of the thermal plume above a sitting person

    DEFF Research Database (Denmark)

    Zukowska, Daria; Popiolek, Zbigniew J.; Melikov, Arsen Krikor

    2009-01-01

    The paper presents a verification of a relatively simple method of volume flux calculation applied to the asymmetrical thermal plume generated by a sitting person in a condition of an upward piston flow. The method is based on a model of a thermal plume above a point heat source in an unbounded...... space. The plume volume flux, V, can be calculated based on the following equation: V = kv*Qexp(1/3)*(zt-zv)exp(5/3). In the equation zt is the distance from the measuring plane to the top of the heat source and Qc is the convective part of the heat loss. A value of the entrainment coefficient, kv...

  15. Evaluation of ECG-gated [(11)C]acetate PET for measuring left ventricular volumes, mass, and myocardial external efficiency.

    Science.gov (United States)

    Hansson, Nils Henrik; Tolbod, Lars; Harms, Johannes; Wiggers, Henrik; Kim, Won Yong; Hansen, Esben; Zaremba, Tomas; Frøkiær, Jørgen; Jakobsen, Steen; Sørensen, Jens

    2016-08-01

    Noninvasive estimation of myocardial external efficiency (MEE) requires measurements of left ventricular (LV) oxygen consumption with [(11)C]acetate PET in addition to LV stroke volume and mass with cardiovascular magnetic resonance (CMR). Measuring LV geometry directly from ECG-gated [(11)C]acetate PET might enable MEE evaluation from a single PET scan. Therefore, we sought to establish the accuracy of measuring LV volumes, mass, and MEE directly from ECG-gated [(11)C]acetate PET. Thirty-five subjects with aortic valve stenosis underwent ECG-gated [(11)C]acetate PET and CMR. List mode PET data were rebinned into 16-bin ECG-gated uptake images before measuring LV volumes and mass using commercial software and compared to CMR. Dynamic datasets were used for calculation of mean LV oxygen consumption and MEE. LV mass, volumes, and ejection fraction measured by CMR and PET correlated strongly (r = 0.86-0.92, P PET (P PET-based MEE, corrected for bias, correlated fairly with PET/CMR-based MEE (r = 0.60, P PET-based MEE bias was strongly associated with LV wall thickness. Although analysis-related improvements in accuracy are recommended, LV geometry estimated from ECG-gated [(11)C]acetate PET correlate excellently with CMR and can indeed be used to evaluate MEE.

  16. Volume and Tissue Composition Changes Measured with Dual-Energy X-Ray Absorptiometry in Melanoma-Related Limb Lymphedema

    DEFF Research Database (Denmark)

    Gjorup, Caroline A; Hendel, Helle W; Zerahn, Bo

    2017-01-01

    Abstracts Background: The aim of this cross-sectional study was to investigate the volume, fat mass, and lean mass in both upper and lower limbs measured with dual-energy X-ray absorptiometry (DXA) in melanoma patients with melanoma-related limb lymphedema. METHODS AND RESULTS: Four hundred thirty...... lymphedema was diagnosed on the basis of history and characteristic physical findings on the clinical examination. The inter-limb differences in volume, fat mass, and lean mass measured with DXA were categorized as none/mild, moderate, or severe according to reference values (taking handedness into account......, and the majority of lymphedemas were categorized as mild. The increase in the volume of limbs with lymphedema was primarily due to an increase in fat mass. CONCLUSION: There is a high prevalence of melanoma-related limb lymphedema. The increase in volume in the limb with lymphedema is primarily due to an increase...

  17. The error sources appearing for the gamma radioactive source measurement in dynamic condition

    International Nuclear Information System (INIS)

    Sirbu, M.

    1977-01-01

    The error analysis for the measurement of the gamma radioactive sources, placed on the soil, with the help of the helicopter are presented. The analysis is based on a new formula that takes account of the attenuation gamma ray factor in the helicopter walls. They give a complete error formula and an error diagram. (author)

  18. Accuracy of Prader orchidometer in measuring testicular volume

    African Journals Online (AJOL)

    2012-10-21

    Oct 21, 2012 ... testicular volumes were then determined by water displacement of the testis. ... tubules and germ cells. ... in a warm room after application of a heating pad (we used ... This mean difference in testicular volume between Prader.

  19. Using National Drug Codes and drug knowledge bases to organize prescription records from multiple sources.

    Science.gov (United States)

    Simonaitis, Linas; McDonald, Clement J

    2009-10-01

    The utility of National Drug Codes (NDCs) and drug knowledge bases (DKBs) in the organization of prescription records from multiple sources was studied. The master files of most pharmacy systems include NDCs and local codes to identify the products they dispense. We obtained a large sample of prescription records from seven different sources. These records carried a national product code or a local code that could be translated into a national product code via their formulary master. We obtained mapping tables from five DKBs. We measured the degree to which the DKB mapping tables covered the national product codes carried in or associated with the sample of prescription records. Considering the total prescription volume, DKBs covered 93.0-99.8% of the product codes from three outpatient sources and 77.4-97.0% of the product codes from four inpatient sources. Among the in-patient sources, invented codes explained 36-94% of the noncoverage. Outpatient pharmacy sources rarely invented codes, which comprised only 0.11-0.21% of their total prescription volume, compared with inpatient pharmacy sources for which invented codes comprised 1.7-7.4% of their prescription volume. The distribution of prescribed products was highly skewed, with 1.4-4.4% of codes accounting for 50% of the message volume and 10.7-34.5% accounting for 90% of the message volume. DKBs cover the product codes used by outpatient sources sufficiently well to permit automatic mapping. Changes in policies and standards could increase coverage of product codes used by inpatient sources.

  20. Numerical study of cesium effects on negative ion production in volume H-and D- ion sources

    International Nuclear Information System (INIS)

    Fukumasa, Osamu; Niitani, Eiji; Yoshino, Kyougo

    1997-01-01

    We present the results of model calculation on H - /D - isotope effects in the tandem volume source. The model includes the surface production due to cesium injection. On the electron density n e dependence of H - /D - production, we have observed an interesting phenomena. Namely D - production, i.e D - density, is higher than H - production in low n e , but in high n e H - production is higher than D - production. The atomic density plays an important role in the density inversion between H - and D - ions. (author)

  1. Technical Note: Influence of Compton currents on profile measurements in small-volume ion chambers

    Energy Technology Data Exchange (ETDEWEB)

    Tanny, Sean; Sperling, Nicholas; Parsai, E. Ishmael, E-mail: e.parsai@utoledo.edu [Department of Radiation Oncology, University of Toledo Medical Center, 1325 Conference Drive, Toledo, Ohio 43614 (United States); Holmes, Shannon [Standard Imaging, 3120 Deming Way, Middleton, Wisconsin 53562 (United States)

    2015-10-15

    Purpose: This work is to evaluate the effects of Compton current generation in three small-volume ionization chambers on measured beam characteristics for electron fields. Methods: Beam scans were performed using Exradin A16, A26, and PTW 31014 microchambers. Scans with varying chamber components shielded were performed. Static point measurements, output factors, and cable only irradiations were performed to determine the contribution of Compton currents to various components of the chamber. Monte Carlo simulations were performed to evaluate why one microchamber showed a significant reduction in Compton current generation. Results: Beam profiles demonstrated significant distortion for two of the three chambers when scanned parallel to the chamber axis, produced by electron deposition within the wire. Measurements of ionization produced within the cable identified Compton current generation as the cause of these distortions. The size of the central collecting wire was found to have the greatest influence on the magnitude of Compton current generation. Conclusions: Microchambers can demonstrate significant (>5%) deviations from properties as measured with larger volume chambers (0.125 cm{sup 3} and above). These deviations can be substantially reduced by averaging measurements conducted at opposite polarities.

  2. Measurement and correlation of excess molar volumes for mixtures of 1-propanol and aromatic hydrocarbons

    International Nuclear Information System (INIS)

    Gahlyan, Suman; Rani, Manju; Maken, Sanjeev Kumar; Lee, Inkyu; Moon, Il

    2015-01-01

    Excess molar volumes (V m E ) have been measured at 303.15 K for 1-propanol+benzene or toluene or o- or m- or p-xylene mixtures using V-shape dilatometer. The V m E values, for an equimolar composition, vary in the order: benzene>toluene-m-xylene>o-xylene>p-xylene. The V m E data have been used to calculate partial molar volumes, excess partial molar volumes, and apparent molar volumes of 1-propanol and aromatic hydrocarbons over the entire range of composition. The excess volume data have also been interpreted in terms of graph-theoretical approach and Prigogine-Flory-Patterson theory (PFP). While PFP theory fails to predict the V m E values for systems with s-shaped V m E versus x 1 graph, the V m E values calculated by graph theory compare reasonably well with the corresponding experimental values. This graph theory analysis has further yielded information about the state of aggregation of pure components as well as of the mixtures

  3. Radio weak lensing shear measurement in the visibility domain - II. Source extraction

    Science.gov (United States)

    Rivi, M.; Miller, L.

    2018-05-01

    This paper extends the method introduced in Rivi et al. (2016b) to measure galaxy ellipticities in the visibility domain for radio weak lensing surveys. In that paper, we focused on the development and testing of the method for the simple case of individual galaxies located at the phase centre, and proposed to extend it to the realistic case of many sources in the field of view by isolating visibilities of each source with a faceting technique. In this second paper, we present a detailed algorithm for source extraction in the visibility domain and show its effectiveness as a function of the source number density by running simulations of SKA1-MID observations in the band 950-1150 MHz and comparing original and measured values of galaxies' ellipticities. Shear measurements from a realistic population of 104 galaxies randomly located in a field of view of 1 \\deg ^2 (i.e. the source density expected for the current radio weak lensing survey proposal with SKA1) are also performed. At SNR ≥ 10, the multiplicative bias is only a factor 1.5 worse than what found when analysing individual sources, and is still comparable to the bias values reported for similar measurement methods at optical wavelengths. The additive bias is unchanged from the case of individual sources, but it is significantly larger than typically found in optical surveys. This bias depends on the shape of the uv coverage and we suggest that a uv-plane weighting scheme to produce a more isotropic shape could reduce and control additive bias.

  4. Development of negative heavy ion sources for plasma potential measurement

    International Nuclear Information System (INIS)

    Sasao, M.; Okabe, Y.; Fujisawa, A.; Iguchi, H.; Fujita, J.; Yamaoka, H.; Wada, M.

    1991-10-01

    A plasma sputter negative ion source was studied for its applicability to the potential measurement of a fusion plasma. Both the beam current density and the beam energy spread are key issues. Energy spectra of a self extracted Au - beam from the source were measured under the condition of a constant work function of the production surface. The full width of half maximum (FWHM) increases from 3 eV to 9 eV monotonically as the target voltage increases from 50 V to 300 V, independently from the target surface work function of 2.2 - 3 eV. (author)

  5. Development of source range measurement instrument in Xi'an pulsed reactor

    CERN Document Server

    Wang Li

    2002-01-01

    Source range measurement instrument in Xi'an pulsed reactor is key equipment of low-side measuring in source range. At the same time, it is also weighty component of out-of-pile neutron-flux level observation system. The authors have done some researching and renovating based on the similar type devices used in nuclear reactor to improve the meter sensitivity, measuring range, noise proof features, reliability in running and maintainability which belong to the main performance index of the instrument. The design ideas, configurations, working principle, performance indexes, technique features and effect in utilizing are introduced briefly

  6. The determination of chromium-50 in human blood and its utilization for blood volume measurements

    International Nuclear Information System (INIS)

    Zeisler, R.; Young, I.

    1986-01-01

    Possible relationships between insufficient blood volume increases during pregnancy and infant mortality could be established with an adequate measurement procedure. An accurate and precise technique for blood volume measurements has been found in the isotope dilution technique using chromium-51 as a label for red blood cells. However, in a study involving pregnant women, only stable isotopes can be used for labeling. Stable chromium-50 can be determined in total blood samples before and after dilution experiments by neutron activation analysis (NAA) or mass spectrometry. However, both techniques may be affected by insufficient sensitivity and contamination problems at the inherently low natural chromium concentrations to be measured in the blood. NAA procedures involving irradiations with highly thermalized neutrons at a fluence rate of 2x10 13 n/cm 2 xs and low background gamma spectrometry are applied to the analysis of total blood. Natural levels of chromium-50 in human and animal blood have been found to be <0.1 ng/mL; i.e., total chromium levels of <3 ng/mL. Based on the NAA procedure, a new approach to the blood volume measurement via chromium-50 isotope dilution has been developed which utilizes the ratio of the induced activities of chromium-51 to the iron-59 in three blood samples taken from each individual, namely blank, labeled and diluted labeled blood. (author)

  7. A framework to measure myocardial extracellular volume fraction using dual-phase low dose CT images

    International Nuclear Information System (INIS)

    Liu, Yixun; Summers, Ronald M.; Yao, Jianhua; Liu, Songtao; Sibley, Christopher T.; Bluemke, David A.; Nacif, Marcelo S.

    2013-01-01

    Purpose: Myocardial extracellular volume fraction (ECVF) is a surrogate imaging biomarker of diffuse myocardial fibrosis, a hallmark of pathologic ventricular remodeling. Low dose cardiac CT is emerging as a promising modality to detect diffuse interstitial myocardial fibrosis due to its fast acquisition and low radiation; however, the insufficient contrast in the low dose CT images poses great challenge to measure ECVF from the image. Methods: To deal with this difficulty, the authors present a complete ECVF measurement framework including a point-guided myocardial modeling, a deformable model-based myocardium segmentation, nonrigid registration of pre- and post-CT, and ECVF calculation. Results: The proposed method was evaluated on 20 patients by two observers. Compared to the manually delineated reference segmentations, the accuracy of our segmentation in terms of true positive volume fraction (TPVF), false positive volume fraction (FPVF), and average surface distance (ASD), were 92.18% ± 3.52%, 0.31% ± 0.10%, 0.69 ± 0.14 mm, respectively. The interobserver variability measured by concordance correlation coefficient regarding TPVF, FPVF, and ASD were 0.95, 0.90, 0.94, respectively, demonstrating excellent agreement. Bland-Altman method showed 95% limits of agreement between ECVF at CT and ECVF at MR. Conclusions: The proposed framework demonstrates its efficiency, accuracy, and noninvasiveness in ECVF measurement and dramatically advances the ECVF at cardiac CT toward its clinical use

  8. A framework to measure myocardial extracellular volume fraction using dual-phase low dose CT images

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Yixun; Summers, Ronald M.; Yao, Jianhua, E-mail: JYao@cc.nih.gov [Clinical Image Processing Service, Radiology and Imaging Sciences, NIH Clinical Center, Bethesda, Maryland 20892 (United States); Liu, Songtao; Sibley, Christopher T.; Bluemke, David A. [Radiology and Imaging Sciences, NIH Clinical Center, Bethesda, Maryland 20892-1182 and Molecular Biomedical Imaging Laboratory, National Institute of Biomedical Imaging and Bioengineering, NIH Clinical Center, Bethesda, Maryland 20892 (United States); Nacif, Marcelo S. [Radiology and Imaging Sciences, NIH Clinical Center, Bethesda, Maryland 20892-1182 (United States)

    2013-10-15

    Purpose: Myocardial extracellular volume fraction (ECVF) is a surrogate imaging biomarker of diffuse myocardial fibrosis, a hallmark of pathologic ventricular remodeling. Low dose cardiac CT is emerging as a promising modality to detect diffuse interstitial myocardial fibrosis due to its fast acquisition and low radiation; however, the insufficient contrast in the low dose CT images poses great challenge to measure ECVF from the image. Methods: To deal with this difficulty, the authors present a complete ECVF measurement framework including a point-guided myocardial modeling, a deformable model-based myocardium segmentation, nonrigid registration of pre- and post-CT, and ECVF calculation. Results: The proposed method was evaluated on 20 patients by two observers. Compared to the manually delineated reference segmentations, the accuracy of our segmentation in terms of true positive volume fraction (TPVF), false positive volume fraction (FPVF), and average surface distance (ASD), were 92.18% ± 3.52%, 0.31% ± 0.10%, 0.69 ± 0.14 mm, respectively. The interobserver variability measured by concordance correlation coefficient regarding TPVF, FPVF, and ASD were 0.95, 0.90, 0.94, respectively, demonstrating excellent agreement. Bland-Altman method showed 95% limits of agreement between ECVF at CT and ECVF at MR. Conclusions: The proposed framework demonstrates its efficiency, accuracy, and noninvasiveness in ECVF measurement and dramatically advances the ECVF at cardiac CT toward its clinical use.

  9. A portable measurement system for subcriticality measurements by the CF-source-driven neutron noise analysis method

    International Nuclear Information System (INIS)

    Mihalczo, J.T.; Ragan, G.E.; Blakeman, E.D.

    1988-01-01

    A portable measurement system consisting of a personal computer used as a Fourier analyzer and three detection channels (with associated electronics that provide the signals to analog-to-digital (A/D) convertors) has been assembled to measure subcriticality by the /sup 252/Cf-source-driven neutron noise analysis method. The /sup 252/Cf-source-driven neutron noise analysis method for obtaining the subcritical neutron multiplication factor of a configuration of fissile material requires measurement of the frequency-dependent cross-power spectral density (CPSD), G/sub 23/(ω), between a pair of detectors (Nos. 2 and 3) located in or near the fissile material and CPSDs G/sub 12/(ω) and G/sub 13/(ω) between these same detectors and a source of neutrons emanating from an ionization chamber (No. 1) containing /sup 252/Cf, also positioned in or near the fissile material. The auto-power spectral density (APSD), G/sub 11/(ω), of the source is also required. A particular ratio of spectral densities, G/sub 12//sup */G/sub 13//G/sub 11/G/sub 23/ (/sup */ denotes complex conjugation), is then formed. This ratio is related to the subcritical neutron multiplication factor and is independent of detector efficiencies

  10. Measurements on Pb27+ Sources for the CERN Heavy Ion Injection Chain

    CERN Document Server

    Chamings, J A

    2004-01-01

    CERN, the world's largest particle physics laboratory near Geneva, is currently in the process of building the Large Hadron Collider (LHC). Lead-208 will be used in this accelerator and to meet the injection requirements much work is required to find a suitable and reliable heavy ion source. The work in this report covers two ion sources, the Laser Ion Source (LIS), and the Electron Cyclotron Resonance Ion Source (ECRIS). An emittance measurement, using a pepper pot and CCD camera, was completed on the recently re-installed LIS, measured and analysed to be 140mm.mrad un-normalised and 0.8mm.mrad normalised 4rms for the maximum intensity charge state, Pb27+. A Visual Basic Program was modified to allow Charge State Distribution (CSD) and other scans of the ECRIS at CERN to be taken. Chapter 5 presents the results of the CSD scans taken. This program provided a new method to take 1 dimensional transverse beam profiles. From this a direct emittance measurement was formed for the first time since the source was o...

  11. Detector characterization for efficiency calibration in different measurement geometries

    International Nuclear Information System (INIS)

    Toma, M.; Dinescu, L.; Sima, O.

    2005-01-01

    In order to perform an accurate efficiency calibration for different measurement geometries a good knowledge of the detector characteristics is required. The Monte Carlo simulation program GESPECOR is applied. The detector characterization required for Monte Carlo simulation is achieved using the efficiency values obtained from measuring a point source. The point source was measured in two significant geometries: the source placed in a vertical plane containing the vertical symmetry axis of the detector and in a horizontal plane containing the centre of the active volume of the detector. The measurements were made using gamma spectrometry technique. (authors)

  12. Revisiting the relationship between tumour volume and diameter in advanced NSCLC patients: An exercise to maximize the utility of each measure to assess response to therapy

    International Nuclear Information System (INIS)

    Nishino, M.; Jackman, D.M.; DiPiro, P.J.; Hatabu, H.; Jänne, P.A.; Johnson, B.E.

    2014-01-01

    Aim: To revisit the presumed relationship between tumour diameter and volume in advanced non-small-cell lung cancer (NSCLC) patients, and determine whether the measured volume using volume-analysis software and its proportional changes during therapy matches with the calculated volume obtained from the presumed relationship and results in concordant response assessment. Materials and methods: Twenty-three patients with stage IIIB/IV NSCLC with a total of 53 measurable lung lesions, treated in a phase II trial of erlotinib, were studied with institutional review board approval. Tumour volume and diameter were measured at baseline and at the first follow-up computed tomography (CT) examination using volume-analysis software. Using the measured diameter (2r) and the equation, calculated volume was obtained as (4/3)πr 3 at baseline and at the follow-up. Percent volume change was obtained by comparing to baseline for measured and calculated volumes, and response assessment was assigned. Results: The measured volume was significantly smaller than the calculated volume at baseline (median 11,488.9 mm 3 versus 17,148.6 mm 3 ; p < 0.0001), with a concordance correlation coefficient (CCC) of 0.7022. At follow-up, the measured volume was once again significantly smaller than the calculated volume (median 6573.5 mm 3 versus 9198.1 mm 3 ; p = 0.0022), with a CCC of 0.7408. Response assessment by calculated versus measured volume changes had only moderate agreement (weighted κ = 0.545), with discordant assessment results in 20% (8/40) of lesions. Conclusion: Calculated volume based on the presumed relationship significantly differed from the measured volume in advanced NSCLC patients, with only moderate concordance in response assessment, indicating the limitations of presumed relationship. - Highlights: • Response assessment by measured vs calculated values has only moderate agreement. • It is important to obtain the actual measured values for tumor response

  13. Application research of tune measurement system in Hefei light source

    International Nuclear Information System (INIS)

    Sun Baogen; He Duohui; Xu Hongliang; Lu Ping; Wang Junhua; Gao Yunfeng; Wang Lin; Liu Jinying

    2002-01-01

    The author introduces the measurement and research of some beam parameters using tune measurement system for Hefei Light Source (HLS), which include the betatron tune, beta function, natural chromaticity, corrected chromaticity, and central frequency. Additionally, it also describes the measurement of the influence of DC clearing electrodes on the betatron tune shift and gives some measurement results. The measurement results are compared with the theoretical values and they are in good agreement

  14. Absorptivity Measurements and Heat Source Modeling to Simulate Laser Cladding

    Science.gov (United States)

    Wirth, Florian; Eisenbarth, Daniel; Wegener, Konrad

    The laser cladding process gains importance, as it does not only allow the application of surface coatings, but also additive manufacturing of three-dimensional parts. In both cases, process simulation can contribute to process optimization. Heat source modeling is one of the main issues for an accurate model and simulation of the laser cladding process. While the laser beam intensity distribution is readily known, the other two main effects on the process' heat input are non-trivial. Namely the measurement of the absorptivity of the applied materials as well as the powder attenuation. Therefore, calorimetry measurements were carried out. The measurement method and the measurement results for laser cladding of Stellite 6 on structural steel S 235 and for the processing of Inconel 625 are presented both using a CO2 laser as well as a high power diode laser (HPDL). Additionally, a heat source model is deduced.

  15. Experimental applications for the MARK-1 and MARK-1A pulsed ionizing radiation detection systems. Volume 3

    International Nuclear Information System (INIS)

    Harker, Y.D.; Lawrence, R.S.; Yoon, W.Y.; Lones, J.L.

    1993-12-01

    This report is the third volume in a three volume set describing the MARK series of pulsed ionizing radiation detection systems. This volume describes the MARK-1A detection system, compares it with the MARK-1 system, and describes the experimental testing of the detection systems. Volume 1 of this set presents the technical specifications for the MARK-1 detection system. Volume 2 is an operations manual specifically for the MARK-1 system, but it generally applies to the MARK-1A system as well. These detection systems operate remotely and detect photon radiation from a single or a multiple pulsed source. They contain multiple detector (eight in the MARK-1 and ten in the MARK-1A) for determination of does and incident photon effective energy. The multiple detector arrangement, having different detector sizes and shield thicknesses, provides the capability of determining the effective photon energy of the radiation spectrum. Dose measurements using these units are consistent with TLD measurements. The detection range is from 3 nanorads to 90 microrads per source burst; the response is linear over that range. Three units were built and are ready for field deployment

  16. [Measurement of the frontal and prefrontal lobe volumes in children with malnutrition by three dimensional magnetic resonance imaging scan].

    Science.gov (United States)

    Kanemura, Hideaki; Aihara, Masao; Nakazawa, Shinpei

    2002-09-01

    To evaluate the effects of malnutrition in early life on the growth of the frontal and prefrontal lobes, we quantitatively measured the volumes of the frontal and prefrontal lobes by three dimensional (3-D) MRI in three children (1 year 2 months to 2 years 5 months) with malnutrition. The 3-D MRI data were acquired by the fast spoiled gradient recalled (SPGR) sequence using a 1.5T MR imager. The frontal and prefrontal lobe volumes were measured by the volume measurement function of the Workstation. The data obtained were compared with those of 16 normal subjects (13 children aged 5 months to 14 years, and 3 adults aged 27 to 39 years). The volumes of the frontal and prefrontal lobes in the subjects were smaller compared with age matched controls. The results suggest that malnutrition in early life affects the growth of the frontal and prefrontal lobes.

  17. A safeguards verification technique for solution homogeneity and volume measurements in process tanks

    International Nuclear Information System (INIS)

    Suda, S.; Franssen, F.

    1987-01-01

    A safeguards verification technique is being developed for determining whether process-liquid homogeneity has been achieved in process tanks and for authenticating volume-measurement algorithms involving temperature corrections. It is proposed that, in new designs for bulk-handling plants employing automated process lines, bubbler probes and thermocouples be installed at several heights in key accountability tanks. High-accuracy measurements of density using an electromanometer can now be made which match or even exceed analytical-laboratory accuracies. Together with regional determination of tank temperatures, these measurements provide density, liquid-column weight and temperature gradients over the fill range of the tank that can be used to ascertain when the tank solution has reached equilibrium. Temperature-correction algorithms can be authenticated by comparing the volumes obtained from the several bubbler-probe liquid-height measurements, each based on different amounts of liquid above and below the probe. The verification technique is based on the automated electromanometer system developed by Brookhaven National Laboratory (BNL). The IAEA has recently approved the purchase of a stainless-steel tank equipped with multiple bubbler and thermocouple probes for installation in its Bulk Calibration Laboratory at IAEA Headquarters, Vienna. The verification technique is scheduled for preliminary trials in late 1987

  18. Measuring of the cerebellar volume of normal Koreans in their 20s and 40s using magnetic resonance imaging

    International Nuclear Information System (INIS)

    Chung, Soon Cheol; Choi, Do Young; Lee, Beob Yi; Lee, Bong Soo; Eom, Jin Sup; Sohn, Jin Hun

    2004-01-01

    This study purposed to measure the standard volume of the cerebellum of normal Koreans who were in their 20s and 40s, and we also wished to find out the difference in the volume of the cerebellum according to gender and age. This study collected MR brain images from 118 people in their 20s (males: 58, females: 60) and 100 people in their 40s (males: 41, females: 59), for a total of 218 people. For each of sagittal, coronal and axial sections, the cerebellar part of the images was segmented using automatic and manual methods, and the volume was then measured. In order to observe differences according to gender and age and also to observe the interactive effect between gender and age, a two-way ANOVA test was performed using gender (2 levels) and age (2 levels) as independent variables. The average volume of the cerebellum of Koreans in their 20s was 133.74 (cm 3 ) and that of Koreans in their 40s was 121.83 (cm 3 ). The average volume of the cerebellum of male Koreans in their 20s and 40s was 134.55 (cm 3 ) and that of female Koreans was 123.06 (cm 3 ). The volume of the cerebellum was significantly larger in Koreans in their 20s than those volumes of the cerebellum of Koreans in their 40s, and the cerebellum volumes in male Koreans were larger than those of the Korean females. Moreover, the reduction of the volume of the cerebellum with age was significantly larger in male Koreans than in the Korean females. According to the results of measuring the volume of the cerebellum for normal Koreans in their 20s and 40s, the volume was significantly different according to gender and age, and the reduction of the volume of the cerebellum with age was significantly larger in men than in women

  19. Measuring of the cerebellar volume of normal Koreans in their 20s and 40s using magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Soon Cheol; Choi, Do Young; Lee, Beob Yi; Lee, Bong Soo [College of Medicine, Konkuk Univ., Chungju (Korea, Republic of); Eom, Jin Sup [Chungbuk National Univ., Chungju (Korea, Republic of); Sohn, Jin Hun [Chungnam National Univ., Daejeon (Korea, Republic of)

    2004-11-01

    This study purposed to measure the standard volume of the cerebellum of normal Koreans who were in their 20s and 40s, and we also wished to find out the difference in the volume of the cerebellum according to gender and age. This study collected MR brain images from 118 people in their 20s (males: 58, females: 60) and 100 people in their 40s (males: 41, females: 59), for a total of 218 people. For each of sagittal, coronal and axial sections, the cerebellar part of the images was segmented using automatic and manual methods, and the volume was then measured. In order to observe differences according to gender and age and also to observe the interactive effect between gender and age, a two-way ANOVA test was performed using gender (2 levels) and age (2 levels) as independent variables. The average volume of the cerebellum of Koreans in their 20s was 133.74 (cm{sup 3}) and that of Koreans in their 40s was 121.83 (cm{sup 3}). The average volume of the cerebellum of male Koreans in their 20s and 40s was 134.55 (cm{sup 3}) and that of female Koreans was 123.06 (cm{sup 3}). The volume of the cerebellum was significantly larger in Koreans in their 20s than those volumes of the cerebellum of Koreans in their 40s, and the cerebellum volumes in male Koreans were larger than those of the Korean females. Moreover, the reduction of the volume of the cerebellum with age was significantly larger in male Koreans than in the Korean females. According to the results of measuring the volume of the cerebellum for normal Koreans in their 20s and 40s, the volume was significantly different according to gender and age, and the reduction of the volume of the cerebellum with age was significantly larger in men than in women.

  20. Cesium-enhanced D sup - beam characteristics from a high-brightness volume source

    Energy Technology Data Exchange (ETDEWEB)

    Debiak, T.W. (Grumman Corporate Research Center, Bethpage, NY (USA))

    1991-05-01

    Previous experiments have demonstrated that the H{sup -} beam extracted from a volume ion source may increase by a factor of 4 or more when cesium vapor is introduced into the arc discharge chamber. We have extended these experiments to cesiated D{sup -} beams transported with and without space-charge neutralization by xenon gas. The D{sup -} results show qualitatively similar characteristics to those obtained with H{sup -}. In particular, a factor of almost 7 in current enhancement was obtained compared with noncesiated beams accompanied by a dramatic reduction in electron current. A study of the beam divergence as a function of extracted equivalent current showed that the divergence of the cesiated beams was larger than the uncesiated beams at the same equivalent current. Introduction of xenon gas at a partial pressure of 2.5x10{sup -5} Torr reduced the divergence of the cesiated beams to the value obtained for the uncesiated beams. (orig.).

  1. Decreased left temporal lobe volume of panic patients measured by magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Uchida, R.R.; Del-Ben, C.M.; Araujo, D.; Crippa, J.A.; Graeff, F.G. [Sao Paulo Univ., Ribeirao Preto, SP (Brazil). Dept. de Neurologia e Psicologia Medica]. E-mail: fgraeff@keynet.com.br; Santos, A.C. [Sao Paulo Univ., Ribeirao Preto, SP (Brazil). Dept. de Clinica Medica; Guimaraes, F.S. [Sao Paulo Univ., Ribeirao Preto, SP (Brazil). Dept. de Farmacologia

    2003-07-01

    Reported neuroimaging studies have shown functional and morphological changes of temporal lobe structures in panic patients, but only one used a volumetric method. The aim of the present study was to determine the volume of temporal lobe structures in patients with panic disorder, measured by magnetic resonance imaging. Eleven panic patients and eleven controls matched for age, sex, handedness, socioeconomic status and years of education participated in the study. The mean volume of the left temporal lobe of panic patients was 9% smaller than that of controls (t{sub 21} = 2.37, P = 0.028). In addition, there was a trend (P values between 0.05 and 0.10) to smaller volumes of the right temporal lobe (7%, t{sub 21} = 1.99, P = 0.06), right amygdala (8%, t{sub 21} = 1.83, P = 0.08), left amygdala (5%, t{sub 21} = 1.78, P 0.09) and left hippocampus (9%, t{sub 21} = 1.93, P = 0.07) in panic patients compared to controls. There was a positive correlation between left hippocampal volume and duration of panic disorder (r = 0.67, P = 0.025), with recent cases showing more reduction than older cases. The present results show that panic patients have a decreased volume of the left temporal lobe and indicate the presence of volumetric abnormalities of temporal lobe structures. (author)

  2. Decreased left temporal lobe volume of panic patients measured by magnetic resonance imaging

    International Nuclear Information System (INIS)

    Uchida, R.R.; Del-Ben, C.M.; Araujo, D.; Crippa, J.A.; Graeff, F.G.; Santos, A.C.; Guimaraes, F.S.

    2003-01-01

    Reported neuroimaging studies have shown functional and morphological changes of temporal lobe structures in panic patients, but only one used a volumetric method. The aim of the present study was to determine the volume of temporal lobe structures in patients with panic disorder, measured by magnetic resonance imaging. Eleven panic patients and eleven controls matched for age, sex, handedness, socioeconomic status and years of education participated in the study. The mean volume of the left temporal lobe of panic patients was 9% smaller than that of controls (t 21 = 2.37, P = 0.028). In addition, there was a trend (P values between 0.05 and 0.10) to smaller volumes of the right temporal lobe (7%, t 21 = 1.99, P = 0.06), right amygdala (8%, t 21 = 1.83, P = 0.08), left amygdala (5%, t 21 = 1.78, P 0.09) and left hippocampus (9%, t 21 = 1.93, P = 0.07) in panic patients compared to controls. There was a positive correlation between left hippocampal volume and duration of panic disorder (r = 0.67, P = 0.025), with recent cases showing more reduction than older cases. The present results show that panic patients have a decreased volume of the left temporal lobe and indicate the presence of volumetric abnormalities of temporal lobe structures. (author)

  3. Prospects for accelerator neutron sources for large volume minerals analysis

    International Nuclear Information System (INIS)

    Clayton, C.G.; Spackman, R.

    1988-01-01

    The electron Linac can be regarded as a practical source of thermal neutrons for activation analysis of large volume mineral samples. With a suitable target and moderator, a neutron flux of about 10 10 n/cm/s over 2-3 kg of rock can be generated. The proton Linac gives the possibility of a high neutron yield (> 10 12 n/s) of fast neutrons at selected energies. For the electron Linac, targets of W-U and W-Be are discussed. The advantages and limitations of the system are demonstrated for the analysis of gold in rocks and ores and for platinum in chromitite. These elements were selected as they are most likely to justify an accelerator installation at the present time. Errors due to self shielding in gold particles for thermal neutrons are discussed. The proton Linac is considered for neutrons generated from a lithium target through the 7 Li(p, n) 7 Be reaction. The analysis of gold by fast neutron activation is considered. This approach avoids particle self-absorption and, by appropriate proton energy selection, avoids potentially dominating interfering reactions. The analysis of 235 U in the presence of 238 U and 232 Th is also considered. (author)

  4. Noninvasive measurement of cardiopulmonary blood volume: evaluation of the centroid method

    International Nuclear Information System (INIS)

    Fouad, F.M.; MacIntyre, W.J.; Tarazi, R.C.

    1981-01-01

    Cardiopulmonary blood volume (CPV) and mean pulmonary transit time (MTT) determined by radionuclide measurements (Tc-99m HSA) were compared with values obtained from simultaneous dye-dilution (DD) studies (indocyanine green). The mean transit time was obtained from radionuclide curves by two methods: the peak-to-peak time and the interval between the two centroids determined from the right and left-ventricular time-concentration curves. Correlation of dye-dilution MTT and peak-to-peak time was significant (r = 0.79, p < 0.001), but its correlation with centroid-derived values was better (r = 0.86, p < 0.001). CPV values (using the centroid method for radionuclide technique) correlated significantly with values derived from dye-dilution curves (r = 0.74, p < 0.001). Discrepancies between the two were greater the more rapid the circulation (r = 0.61, p < 0.01), suggesting that minor inaccuracies of dye-dilution methods, due to positioning or delay of the system, can become magnified in hyperkinetic conditions. The radionuclide method is simple, repeatable, and noninvasive, and it provides simultaneous evaluation of pulmonary and systemic hemodynamics. Further, calculation of the ratio of cardiopulmonary to total blood volume can be used as an index of overall venous distensibility and relocation of intravascular blood volume

  5. Dynamic Aperture Measurements at the Advanced Light Source

    International Nuclear Information System (INIS)

    Decking, W.; Robin, D.

    1999-01-01

    A large dynamic aperture for a storage ring is of importance for long lifetimes and a high injection efficiency. Measurements of the dynamic aperture of the third generation synchrotron light source Advanced Light Source (ALS) using beam excitation with kicker magnets are presented. The experiments were done for various accelerator conditions, allowing us to investigate the influence of different working points, chromaticities, insertion devices, etc.. The results are compared both with tracking calculations and a simple model for the dynamic aperture yielding good agreements. This gives us confidence in the predictability of the nonlinear accelerator model. This is especially important for future ALS upgrades as well as new storage ring designs

  6. Measuring light spectrum as a main indicator of artificial sources quality

    Directory of Open Access Journals (Sweden)

    Piotr Dąbrowski

    2015-05-01

    Full Text Available Objective: To compare different artificial light sources in different places where plant breeding is conduced. Methods: Measurements were conducted outdoor, in room, in greenhouse, under four panels with light emitting diodes, in phytotron, in dark room with various light sources and inside Sanyo versatile environmental chamber. The measurements were made by using SpectraPen SP100 (PSI, Czech Republic device. Results: Our result showed that spectrum measured outdoor during sunny day had only one peak at the wavelength of 485 nm (ca. 60000 relative units. On cloudy day, the trend of light spectrum curve was similar, but with lower values. At room conditions, the curve was more flat than outdoor. Under greenhouse conditions, the curve was similar to that measured outdoor. A few additional peaks on the curve appeared by adding high pressure sodium lamp. There were changes of curve under LED panels. Conclusions: It must be underlined that the most similar spectrum curve to daylight light has incandescent bulb and this light source should be preferred as support of daylight in greenhouses and as main source in phytotrons. Using high pressure sodium lamp in greenhouses as support of daylight cause increase in the red/far-red ratio and occurrence of a new peak on spectrum curve. The new possibilities are creating by LED panels with red and blue diodes.

  7. The advantages of a swept source optical coherence tomography system in the evaluation of occlusal disorders

    Science.gov (United States)

    Marcauteanu, Corina; Bradu, Adrian; Sinescu, Cosmin; Topala, Florin Ionel; Negrutiu, Meda Lavinia; Duma, Virgil Florin; Podoleanu, Adrian Gh.

    2014-01-01

    Occlusal disorders are characterized by multiple dental and periodontal signs. Some of these are reversible (such as excessive tooth mobility, fremitus, tooth pain, migration of teeth in the absence of periodontitis), some are not (pathological occlusal/incisal wear, abfractions, enamel cracks, tooth fractures, gingival recessions). In this paper we prove the advantages of a fast swept source OCT system in the diagnosis of pathological incisal wear, a key sign of the occlusal disorders. On 15 extracted frontal teeth four levels of pathological incisal wear facets were artificially created. After every level of induced defect, OCT scanning was performed. B scans were acquired and 3D reconstructions were generated. A swept source OCT instrument is used in this study. The swept source is has a central wavelength of 1050 nm and a sweeping rate of 100 kHz. A depth resolution determined by the swept source of 12 μm in air was experimentally measured. The pathological incisal wear is qualitatively observed on the B-scans as 2D images and 3D reconstructions (volumes). For quantitative evaluations of volumes, we used the Image J software. Our swept source OCT system has several advantages, including the ability to measure (in air) a minimal volume of 2352 μm3 and to collect high resolution volumetric images in 2.5 s. By calculating the areas of the amount of lost tissue corresponding to each difference of B-scans, the final volumes of incisal wear were obtained. This swept source OCT method is very useful for the dynamic evaluation of pathological incisal wear.

  8. Validation of hippocampal volumes measured using a manual method and two automated methods (FreeSurfer and IBASPM) in chronic major depressive disorder

    Energy Technology Data Exchange (ETDEWEB)

    Tae, Woo Suk; Lee, Kang Uk; Nam, Eui-Cheol; Kim, Keun Woo [Kangwon National University College of Medicine, Neuroscience Research Institute, Kangwon (Korea); Kim, Sam Soo [Kangwon National University College of Medicine, Neuroscience Research Institute, Kangwon (Korea); Kangwon National University Hospital, Department of Radiology, Kangwon-do (Korea)

    2008-07-15

    To validate the usefulness of the packages available for automated hippocampal volumetry, we measured hippocampal volumes using one manual and two recently developed automated volumetric methods. The study included T1-weighted magnetic resonance imaging (MRI) of 21 patients with chronic major depressive disorder (MDD) and 20 normal controls. Using coronal turbo field echo (TFE) MRI with a slice thickness of 1.3 mm, the hippocampal volumes were measured using three methods: manual volumetry, surface-based parcellation using FreeSurfer, and individual atlas-based volumetry using IBASPM. In addition, the intracranial cavity volume (ICV) was measured manually. The absolute left hippocampal volume of the patients with MDD measured using all three methods was significantly smaller than the left hippocampal volume of the normal controls (manual P=0.029, FreeSurfer P=0.035, IBASPM P=0.018). After controlling for the ICV, except for the right hippocampal volume measured using FreeSurfer, both measured hippocampal volumes of the patients with MDD were significantly smaller than the measured hippocampal volumes of the normal controls (right manual P=0.019, IBASPM P=0.012; left manual P=0.003, FreeSurfer P=0.010, IBASPM P=0.002). In the intrarater reliability test, the intraclass correlation coefficients (ICCs) were all excellent (manual right 0.947, left 0.934; FreeSurfer right 1.000, left 1.000; IBASPM right 1.000, left 1.000). In the test of agreement between the volumetric methods, the ICCs were right 0.846 and left 0.848 (manual and FreeSurfer), and right 0.654 and left 0.717 (manual and IBASPM). The automated hippocampal volumetric methods showed good agreement with manual hippocampal volumetry, but the volume measured using FreeSurfer was 35% larger and the agreement was questionable with IBASPM. Although the automated methods could detect hippocampal atrophy in the patients with MDD, the results indicate that manual hippocampal volumetry is still the gold standard

  9. Validation of hippocampal volumes measured using a manual method and two automated methods (FreeSurfer and IBASPM) in chronic major depressive disorder

    International Nuclear Information System (INIS)

    Tae, Woo Suk; Lee, Kang Uk; Nam, Eui-Cheol; Kim, Keun Woo; Kim, Sam Soo

    2008-01-01

    To validate the usefulness of the packages available for automated hippocampal volumetry, we measured hippocampal volumes using one manual and two recently developed automated volumetric methods. The study included T1-weighted magnetic resonance imaging (MRI) of 21 patients with chronic major depressive disorder (MDD) and 20 normal controls. Using coronal turbo field echo (TFE) MRI with a slice thickness of 1.3 mm, the hippocampal volumes were measured using three methods: manual volumetry, surface-based parcellation using FreeSurfer, and individual atlas-based volumetry using IBASPM. In addition, the intracranial cavity volume (ICV) was measured manually. The absolute left hippocampal volume of the patients with MDD measured using all three methods was significantly smaller than the left hippocampal volume of the normal controls (manual P=0.029, FreeSurfer P=0.035, IBASPM P=0.018). After controlling for the ICV, except for the right hippocampal volume measured using FreeSurfer, both measured hippocampal volumes of the patients with MDD were significantly smaller than the measured hippocampal volumes of the normal controls (right manual P=0.019, IBASPM P=0.012; left manual P=0.003, FreeSurfer P=0.010, IBASPM P=0.002). In the intrarater reliability test, the intraclass correlation coefficients (ICCs) were all excellent (manual right 0.947, left 0.934; FreeSurfer right 1.000, left 1.000; IBASPM right 1.000, left 1.000). In the test of agreement between the volumetric methods, the ICCs were right 0.846 and left 0.848 (manual and FreeSurfer), and right 0.654 and left 0.717 (manual and IBASPM). The automated hippocampal volumetric methods showed good agreement with manual hippocampal volumetry, but the volume measured using FreeSurfer was 35% larger and the agreement was questionable with IBASPM. Although the automated methods could detect hippocampal atrophy in the patients with MDD, the results indicate that manual hippocampal volumetry is still the gold standard

  10. Semi-empirical Calculation of Detection Efficiency for Voluminous Source Based on Effective Solid Angle Concept

    Energy Technology Data Exchange (ETDEWEB)

    Kang, M. Y.; Kim, J. H.; Choi, H. D.; Sun, G. M. [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2014-10-15

    To calculate the full energy (FE) absorption peak efficiency for arbitrary volume sample, we developed and verified the Effective Solid Angle (ESA) Code. The procedure for semi-empirical determination of the FE efficiency for the arbitrary volume sources and the calculation principles and processes about ESA code is referred to, and the code was validated with a HPGe detector (relative efficiency 32%, n-type) in previous studies. In this study, we use different type and efficiency of HPGe detectors, in order to verify the performance of the ESA code for the various detectors. We calculated the efficiency curve of voluminous source and compared with experimental data. We will carry out additional validation by measurement of various medium, volume and shape of CRM volume sources with detector of different efficiency and type. And we will reflect the effect of the dead layer of p-type HPGe detector and coincidence summing correction technique in near future.

  11. Measurement and correction of chromaticity in Hefei light source

    International Nuclear Information System (INIS)

    Sun Baogen; Xu Hongliang; He Duohui; Wang Junhua; Lu Ping

    2001-01-01

    The measurement and correction of chromaticity for Hefei light source is introduced. The natural chromaticity is obtained by detecting the variation of the betatron tune with the main dipole field strength. The correction chromaticity is obtained by detecting the variation of the betatron tune with the RF frequency. The theoretic analysis and formula for the two methods is given. The measurement results of chromaticity are given

  12. Measurement of thyroid volume, iodine concentration and total iodine content by CT and its clinical significance

    International Nuclear Information System (INIS)

    Nakaji, Shunsuke; Imanishi, Yoshimasa; Okamoto, Kyouko; Shinagawa, Toshihito

    2007-01-01

    Recently, Imanishi et al have developed new CT software for quantitative in vivo measurement of thyroid iodine. Using a CT system with the software, we measured volume, iodine concentration and total iodine content of thyroids in 63 controls and 435 patients with various diffuse thyroid diseases and thyroid nodules. In controls, all of them showed no difference between the sexes. Although the iodine concentration of the thyroid showed no difference among children, adults and seniles, the volume and total iodine content of the thyroid appeared smaller in children and seniles than in adults. In addition, although the volume and iodine concentration of the thyroid had two peaks in distribution, the total iodine content had almost normal distribution. Normal range of volume, iodine concentration and total iodine content in adults were 5.2-15.5 cm 3 , 0.28831-0.85919 mg/cm 3 and 2.35-11.69 mg, respectively. In thyroid nodule, there is no significant difference in volume, iodine concentration and total iodine content between benign and malignant nodules. All nodules with iodine concentration of less than 0.00007 mg/cm 3 were benign. No thyroid was higher in iodine concentration than the normal range although the thyroid was lower in 78.7% of patients with diffuse thyroid diseases. In all thyroids with increasing iodine concentration and total iodine content in medication course, thyroidal symptoms and signs were uncontrollable by the medication. In 43.8% of patients with long-period systemic diseases, the thyroid showed abnormality in any of the three. We concluded that quantitative in vivo measurement of thyroid iodine by CT could assist the diagnosis of thyroid diseases and decision of therapeutic methods. (author)

  13. Implementation of Energy Strategies in Communities (Annex 63) Volume 2: Development of strategic measures

    DEFF Research Database (Denmark)

    Kellenberger, Daniel; Schmid, Christian; Quitzau, Maj-Britt

    This report describes the further development of the analysed measures from Volume 1 into strategic measures. As with the term measure, a strategic measure refers to an essential measure in concept that can be used to develop individual implementation strategies on a local level for part...... or the whole life cycle of a project (from the first vision to monitoring of the implemented solution). The developed strategic measures deal with the following topics: Setting Vision and Targets Developing Renewable Energy Strategies Making Full use of Legal Frameworks Designing an Urban Competition Processes...... a summary of each strategic measure supported by nine appendices, each a detailed description of each strategic measure....

  14. A new oxidation flow reactor for measuring secondary aerosol formation of rapidly changing emission sources

    Science.gov (United States)

    Simonen, Pauli; Saukko, Erkka; Karjalainen, Panu; Timonen, Hilkka; Bloss, Matthew; Aakko-Saksa, Päivi; Rönkkö, Topi; Keskinen, Jorma; Dal Maso, Miikka

    2017-04-01

    Oxidation flow reactors (OFRs) or environmental chambers can be used to estimate secondary aerosol formation potential of different emission sources. Emissions from anthropogenic sources, such as vehicles, often vary on short timescales. For example, to identify the vehicle driving conditions that lead to high potential secondary aerosol emissions, rapid oxidation of exhaust is needed. However, the residence times in environmental chambers and in most oxidation flow reactors are too long to study these transient effects ( ˜ 100 s in flow reactors and several hours in environmental chambers). Here, we present a new oxidation flow reactor, TSAR (TUT Secondary Aerosol Reactor), which has a short residence time ( ˜ 40 s) and near-laminar flow conditions. These improvements are achieved by reducing the reactor radius and volume. This allows studying, for example, the effect of vehicle driving conditions on the secondary aerosol formation potential of the exhaust. We show that the flow pattern in TSAR is nearly laminar and particle losses are negligible. The secondary organic aerosol (SOA) produced in TSAR has a similar mass spectrum to the SOA produced in the state-of-the-art reactor, PAM (potential aerosol mass). Both reactors produce the same amount of mass, but TSAR has a higher time resolution. We also show that TSAR is capable of measuring the secondary aerosol formation potential of a vehicle during a transient driving cycle and that the fast response of TSAR reveals how different driving conditions affect the amount of formed secondary aerosol. Thus, TSAR can be used to study rapidly changing emission sources, especially the vehicular emissions during transient driving.

  15. A measurement-based generalized source model for Monte Carlo dose simulations of CT scans.

    Science.gov (United States)

    Ming, Xin; Feng, Yuanming; Liu, Ransheng; Yang, Chengwen; Zhou, Li; Zhai, Hezheng; Deng, Jun

    2017-03-07

    The goal of this study is to develop a generalized source model for accurate Monte Carlo dose simulations of CT scans based solely on the measurement data without a priori knowledge of scanner specifications. The proposed generalized source model consists of an extended circular source located at x-ray target level with its energy spectrum, source distribution and fluence distribution derived from a set of measurement data conveniently available in the clinic. Specifically, the central axis percent depth dose (PDD) curves measured in water and the cone output factors measured in air were used to derive the energy spectrum and the source distribution respectively with a Levenberg-Marquardt algorithm. The in-air film measurement of fan-beam dose profiles at fixed gantry was back-projected to generate the fluence distribution of the source model. A benchmarked Monte Carlo user code was used to simulate the dose distributions in water with the developed source model as beam input. The feasibility and accuracy of the proposed source model was tested on a GE LightSpeed and a Philips Brilliance Big Bore multi-detector CT (MDCT) scanners available in our clinic. In general, the Monte Carlo simulations of the PDDs in water and dose profiles along lateral and longitudinal directions agreed with the measurements within 4%/1 mm for both CT scanners. The absolute dose comparison using two CTDI phantoms (16 cm and 32 cm in diameters) indicated a better than 5% agreement between the Monte Carlo-simulated and the ion chamber-measured doses at a variety of locations for the two scanners. Overall, this study demonstrated that a generalized source model can be constructed based only on a set of measurement data and used for accurate Monte Carlo dose simulations of patients' CT scans, which would facilitate patient-specific CT organ dose estimation and cancer risk management in the diagnostic and therapeutic radiology.

  16. A measurement-based generalized source model for Monte Carlo dose simulations of CT scans

    Science.gov (United States)

    Ming, Xin; Feng, Yuanming; Liu, Ransheng; Yang, Chengwen; Zhou, Li; Zhai, Hezheng; Deng, Jun

    2017-03-01

    The goal of this study is to develop a generalized source model for accurate Monte Carlo dose simulations of CT scans based solely on the measurement data without a priori knowledge of scanner specifications. The proposed generalized source model consists of an extended circular source located at x-ray target level with its energy spectrum, source distribution and fluence distribution derived from a set of measurement data conveniently available in the clinic. Specifically, the central axis percent depth dose (PDD) curves measured in water and the cone output factors measured in air were used to derive the energy spectrum and the source distribution respectively with a Levenberg-Marquardt algorithm. The in-air film measurement of fan-beam dose profiles at fixed gantry was back-projected to generate the fluence distribution of the source model. A benchmarked Monte Carlo user code was used to simulate the dose distributions in water with the developed source model as beam input. The feasibility and accuracy of the proposed source model was tested on a GE LightSpeed and a Philips Brilliance Big Bore multi-detector CT (MDCT) scanners available in our clinic. In general, the Monte Carlo simulations of the PDDs in water and dose profiles along lateral and longitudinal directions agreed with the measurements within 4%/1 mm for both CT scanners. The absolute dose comparison using two CTDI phantoms (16 cm and 32 cm in diameters) indicated a better than 5% agreement between the Monte Carlo-simulated and the ion chamber-measured doses at a variety of locations for the two scanners. Overall, this study demonstrated that a generalized source model can be constructed based only on a set of measurement data and used for accurate Monte Carlo dose simulations of patients’ CT scans, which would facilitate patient-specific CT organ dose estimation and cancer risk management in the diagnostic and therapeutic radiology.

  17. A Safe, Self-Calibrating, Wireless System for Measuring Volume of Any Fuel at Non-Horizontal Orientation

    Science.gov (United States)

    Woodward, Stanley E.; Taylor, Bryant D.

    2010-01-01

    A system for wirelessly measuring the volume of fluid in tanks at non-horizontal orientation is predicated upon two technologies developed at Langley Research Center. The first is a magnetic field response recorder that powers and interrogates magnetic field response sensors [ Magnetic Field Response Measurement Acquisition System, (LAR-16908), NASA Tech Briefs, Vol. 30, No. 6 (June 2006), page 28]. Magnetic field response sensors are a class of sensors that are powered via oscillating magnetic fields and when electrically active respond with their own magnetic fields whose attributes are dependent upon the magnitude of the physical quantity being measured. The response recorder facilitates the use of the second technology, which is a magnetic field response fluid-level sensor ["Wireless Fluid- Level Sensors for Harsh Environments," (LAR-17155), NASA Tech Briefs, Vol. 33, No. 4 (April 2009), page 30]. The method for powering and interrogating the sensors allows them to be completely encased in materials (Fig. 1) that are chemically resilient to the fluid being measured, thereby facilitating measurement of substances (e.g., acids, petroleum, cryogenic, caustic, and the like) that would normally destroy electronic circuitry. When the sensors are encapsulated, no fluid (or fluid vapor) is exposed to any electrical component of the measurement system. There is no direct electrical line from the vehicle or plant power into a fuel container. The means of interrogating and powering the sensors can be completely physically and electrically isolated from the fuel and vapors by placing the sensor on the other side of an electrically non-conductive bulkhead (Fig. 2). These features prevent the interrogation system and its electrical components from becoming an ignition source.

  18. Non-invasive assessment of peripheral arterial disease: Automated ankle brachial index measurement and pulse volume analysis compared to duplex scan.

    Science.gov (United States)

    Lewis, Jane Ea; Williams, Paul; Davies, Jane H

    2016-01-01

    This cross-sectional study aimed to individually and cumulatively compare sensitivity and specificity of the (1) ankle brachial index and (2) pulse volume waveform analysis recorded by the same automated device, with the presence or absence of peripheral arterial disease being verified by ultrasound duplex scan. Patients (n=205) referred for lower limb arterial assessment underwent ankle brachial index measurement and pulse volume waveform recording using volume plethysmography, followed by ultrasound duplex scan. The presence of peripheral arterial disease was recorded if ankle brachial index 50% was evident with ultrasound duplex scan. Outcome measure was agreement between the measured ankle brachial index and interpretation of pulse volume waveform for peripheral arterial disease diagnosis, using ultrasound duplex scan as the reference standard. Sensitivity of ankle brachial index was 79%, specificity 91% and overall accuracy 88%. Pulse volume waveform sensitivity was 97%, specificity 81% and overall accuracy 85%. The combined sensitivity of ankle brachial index and pulse volume waveform was 100%, specificity 76% and overall accuracy 85%. Combining these two diagnostic modalities within one device provided a highly accurate method of ruling out peripheral arterial disease, which could be utilised in primary care to safely reduce unnecessary secondary care referrals.

  19. Calculating regional tissue volume for hyperthermic isolated limb perfusion: Four methods compared.

    Science.gov (United States)

    Cecchin, D; Negri, A; Frigo, A C; Bui, F; Zucchetta, P; Bodanza, V; Gregianin, M; Campana, L G; Rossi, C R; Rastrelli, M

    2016-12-01

    Hyperthermic isolated limb perfusion (HILP) can be performed as an alternative to amputation for soft tissue sarcomas and melanomas of the extremities. Melphalan and tumor necrosis factor-alpha are used at a dosage that depends on the volume of the limb. Regional tissue volume is traditionally measured for the purposes of HILP using water displacement volumetry (WDV). Although this technique is considered the gold standard, it is time-consuming and complicated to implement, especially in obese and elderly patients. The aim of the present study was to compare the different methods described in the literature for calculating regional tissue volume in the HILP setting, and to validate an open source software. We reviewed the charts of 22 patients (11 males and 11 females) who had non-disseminated melanoma with in-transit metastases or sarcoma of the lower limb. We calculated the volume of the limb using four different methods: WDV, tape measurements and segmentation of computed tomography images using Osirix and Oncentra Masterplan softwares. The overall comparison provided a concordance correlation coefficient (CCC) of 0.92 for the calculations of whole limb volume. In particular, when Osirix was compared with Oncentra (validated for volume measures and used in radiotherapy), the concordance was near-perfect for the calculation of the whole limb volume (CCC = 0.99). With methods based on CT the user can choose a reliable plane for segmentation purposes. CT-based methods also provides the opportunity to separate the whole limb volume into defined tissue volumes (cortical bone, fat and water). Copyright © 2016 Elsevier Ltd. All rights reserved.

  20. Method and timing of tumor volume measurement for outcome prediction in cervical cancer using magnetic resonance imaging

    International Nuclear Information System (INIS)

    Mayr, Nina A.; Taoka, Toshiaki; Yuh, William T.C.; Denning, Leah M.; Zhen, Weining K.; Paulino, Arnold C.; Gaston, Robert C.; Sorosky, Joel I.; Meeks, Sanford L.; Walker, Joan L.; Mannel, Robert S.; Buatti, John M.

    2002-01-01

    Purpose: Recently, imaging-based tumor volume before, during, and after radiation therapy (RT) has been shown to predict tumor response in cervical cancer. However, the effectiveness of different methods and timing of imaging-based tumor size assessment have not been investigated. The purpose of this study was to compare the predictive value for treatment outcome derived from simple diameter-based ellipsoid tumor volume measurement using orthogonal diameters (with ellipsoid computation) with that derived from more complex contour tracing/region-of-interest (ROI) analysis 3D tumor volumetry. Methods and Materials: Serial magnetic resonance imaging (MRI) examinations were prospectively performed in 60 patients with advanced cervical cancer (Stages IB 2 -IVB/recurrent) at the start of RT, during early RT (20-25 Gy), mid-RT (45-50 Gy), and at follow-up (1-2 months after RT completion). ROI-based volumetry was derived by tracing the entire tumor region in each MR slice on the computer work station. For the diameter-based surrogate ''ellipsoid volume,'' the three orthogonal diameters (d 1 , d 2 , d 3 ) were measured on film hard copies to calculate volume as an ellipsoid (d 1 x d 2 x d 3 x π/6). Serial tumor volumes and regression rates determined by each method were correlated with local control, disease-free and overall survival, and the results were compared between the two measuring methods. Median post-therapy follow-up was 4.9 years (range, 2.0-8.2 years). Results: The best method and time point of tumor size measurement for the prediction of outcome was the tumor regression rate in the mid-therapy MRI examination (at 45-50 Gy) using 3D ROI volumetry. For the pre-RT measurement both the diameter-based method and ROI volumetry provided similar predictive accuracy, particularly for patients with small ( 3 ) and large (≥100 cm 3 ) pre-RT tumor size. However, the pre-RT tumor size measured by either method had much less predictive value for the intermediate-size (40

  1. Can Emergency Physicians Perform Common Carotid Doppler Flow Measurements to Assess Volume Responsiveness?

    Directory of Open Access Journals (Sweden)

    Stolz, Lori A.

    2015-02-01

    Full Text Available Introduction: Common carotid flow measurements may be clinically useful to determine volume responsiveness. The objective of this study was to assess the ability of emergency physicians (EP to obtain sonographic images and measurements of the common carotid artery velocity time integral (VTi for potential use in assessing volume responsiveness in the clinical setting. Methods: In this prospective observational study, we showed a five-minute instructional video demonstrating a technique to obtain common carotid ultrasound images and measure the common carotid VTi to emergency medicine (EM residents. Participants were then asked to image the common carotid artery and obtain VTi measurements. Expert sonographers observed participants imaging in real time and recorded their performance on nine performance measures. An expert sonographer graded image quality. Participants were timed and answered questions regarding ease of examination and their confidence in obtaining the images. Results: A total of 30 EM residents participated in this study and each performed the examination twice. Average time required to complete one examination was 2.9 minutes (95% CI [2.4-3.4 min]. Participants successfully completed all performance measures greater than 75% of the time, with the exception of obtaining measurements during systole, which was completed in 65% of examinations. Median resident overall confidence in accurately performing carotid VTi measurements was 3 (on a scale of 1 [not confident] to 5 [confident]. Conclusion: EM residents at our institution learned the technique for obtaining common carotid artery Doppler flow measurements after viewing a brief instructional video. When assessed at performing this examination, they completed several performance measures with greater than 75% success. No differences were found between novice and experienced groups. [West J Emerg Med. 2015;16(2:255–259.

  2. Electrochemical Power Sources

    Indian Academy of Sciences (India)

    Home; Journals; Resonance – Journal of Science Education; Volume 6; Issue 7. Electrochemical Power Sources - Rechargeable Batteries. A K Shukla S K Martha. General Article Volume 6 Issue 7 July 2001 pp 52-63. Fulltext. Click here to view fulltext PDF. Permanent link:

  3. Measurements of bremsstrahlung spectra of Lanzhou ECR Ion Source No. 3 (LECR3)

    International Nuclear Information System (INIS)

    Zhao, H.Y.; Zhao, H.W.; Ma, X.W.; Zhang, S.F.; Feng, W.T.; Zhu, X.L.; Zhang, Z.M.; He, W.; Sun, L.T.; Feng, Y.C.; Cao, Y.; Li, J.Y.; Li, X.X.; Wang, H.; Ma, B.H.

    2006-01-01

    In order to diagnose the electron cyclotron resonance (ECR) plasma, electron bremsstrahlung spectra were measured by a HPGe detector on Lanzhou ECR Ion Source No. 3 at IMP. The ion source was operated with argon under various working conditions, including different microwave power, mixing gas, extraction high voltage (HV), and so on. Some of the measured spectra are presented in this article. The dependence of energetic electron population on mixing gas and extraction HV is also described. Additionally, we are looking forward to further measurements on SECRAL (Superconducting ECR Ion Source with Advanced design at Lanzhou)

  4. Radio measurements in the fields of gamma-ray sources. Pt. 1

    International Nuclear Information System (INIS)

    Sieber, W.; Schlickeiser, R.

    1982-01-01

    The γ-ray source CG 195+04 has been searched for radio counterparts at wavelengths between 2.8 cm and 18 cm with the 100-m telescope of the Max-Planck-Institut fuer Radioastronomie, Bonn. We have detected a number of sources and measured their spectra. Our positions may form the basis for future surveys in other frequency ranges. Different physical emission models suggest compactness of the γ-ray source. (orig.)

  5. Volume measurements of individual muscles in human quadriceps femoris using atlas-based segmentation approaches.

    Science.gov (United States)

    Le Troter, Arnaud; Fouré, Alexandre; Guye, Maxime; Confort-Gouny, Sylviane; Mattei, Jean-Pierre; Gondin, Julien; Salort-Campana, Emmanuelle; Bendahan, David

    2016-04-01

    Atlas-based segmentation is a powerful method for automatic structural segmentation of several sub-structures in many organs. However, such an approach has been very scarcely used in the context of muscle segmentation, and so far no study has assessed such a method for the automatic delineation of individual muscles of the quadriceps femoris (QF). In the present study, we have evaluated a fully automated multi-atlas method and a semi-automated single-atlas method for the segmentation and volume quantification of the four muscles of the QF and for the QF as a whole. The study was conducted in 32 young healthy males, using high-resolution magnetic resonance images (MRI) of the thigh. The multi-atlas-based segmentation method was conducted in 25 subjects. Different non-linear registration approaches based on free-form deformable (FFD) and symmetric diffeomorphic normalization algorithms (SyN) were assessed. Optimal parameters of two fusion methods, i.e., STAPLE and STEPS, were determined on the basis of the highest Dice similarity index (DSI) considering manual segmentation (MSeg) as the ground truth. Validation and reproducibility of this pipeline were determined using another MRI dataset recorded in seven healthy male subjects on the basis of additional metrics such as the muscle volume similarity values, intraclass coefficient, and coefficient of variation. Both non-linear registration methods (FFD and SyN) were also evaluated as part of a single-atlas strategy in order to assess longitudinal muscle volume measurements. The multi- and the single-atlas approaches were compared for the segmentation and the volume quantification of the four muscles of the QF and for the QF as a whole. Considering each muscle of the QF, the DSI of the multi-atlas-based approach was high 0.87 ± 0.11 and the best results were obtained with the combination of two deformation fields resulting from the SyN registration method and the STEPS fusion algorithm. The optimal variables for FFD

  6. Study of localized photon source in space of measures

    International Nuclear Information System (INIS)

    Lisi, M.

    2010-01-01

    In this paper we study a three-dimensional photon transport problem in an interstellar cloud, with a localized photon source inside. The problem is solved indirectly, by defining the adjoint of an operator acting on an appropriate space of continuous functions. By means of sun-adjoint semi groups theory of operators in a Banach space of regular Borel measures, we prove existence and uniqueness of the solution of the problem. A possible approach to identify the localization of the photon source is finally proposed.

  7. Machine vision for high-precision volume measurement applied to levitated containerless material processing

    International Nuclear Information System (INIS)

    Bradshaw, R.C.; Schmidt, D.P.; Rogers, J.R.; Kelton, K.F.; Hyers, R.W.

    2005-01-01

    By combining the best practices in optical dilatometry with numerical methods, a high-speed and high-precision technique has been developed to measure the volume of levitated, containerlessly processed samples with subpixel resolution. Containerless processing provides the ability to study highly reactive materials without the possibility of contamination affecting thermophysical properties. Levitation is a common technique used to isolate a sample as it is being processed. Noncontact optical measurement of thermophysical properties is very important as traditional measuring methods cannot be used. Modern, digitally recorded images require advanced numerical routines to recover the subpixel locations of sample edges and, in turn, produce high-precision measurements

  8. Determination of a normogram for testicular volume measured by ...

    African Journals Online (AJOL)

    4.67years, 1.18±0.29m, 24.79±14.76kg and 15.82±2.63kg/m2. The mean testicular volume in the study population was 1.93±3.31ml. The right and left mean testicular volume were 2.27±+3.66ml and 2.23±3.61ml, respectively. Testicular volume ...

  9. Measurement and correlation of excess molar volumes for mixtures of 1-propanol and aromatic hydrocarbons

    Energy Technology Data Exchange (ETDEWEB)

    Gahlyan, Suman; Rani, Manju; Maken, Sanjeev Kumar [Deenbandhu Chhotu Ram University of Science and Technology, Murthal (India); Lee, Inkyu; Moon, Il [Yonsei University, Seoul (Korea, Republic of)

    2015-01-15

    Excess molar volumes (V{sub m}{sup E} ) have been measured at 303.15 K for 1-propanol+benzene or toluene or o- or m- or p-xylene mixtures using V-shape dilatometer. The V{sub m}{sup E} values, for an equimolar composition, vary in the order: benzene>toluene-m-xylene>o-xylene>p-xylene. The V{sub m}{sup E} data have been used to calculate partial molar volumes, excess partial molar volumes, and apparent molar volumes of 1-propanol and aromatic hydrocarbons over the entire range of composition. The excess volume data have also been interpreted in terms of graph-theoretical approach and Prigogine-Flory-Patterson theory (PFP). While PFP theory fails to predict the V{sub m}{sup E} values for systems with s-shaped V{sub m}{sup E} versus x{sub 1} graph, the V{sub m}{sup E} values calculated by graph theory compare reasonably well with the corresponding experimental values. This graph theory analysis has further yielded information about the state of aggregation of pure components as well as of the mixtures.

  10. Characterizing functional lung heterogeneity in COPD using reference equations for CT scan-measured lobar volumes.

    Science.gov (United States)

    Come, Carolyn E; Diaz, Alejandro A; Curran-Everett, Douglas; Muralidhar, Nivedita; Hersh, Craig P; Zach, Jordan A; Schroeder, Joyce; Lynch, David A; Celli, Bartolome; Washko, George R

    2013-06-01

    CT scanning is increasingly used to characterize COPD. Although it is possible to obtain CT scan-measured lung lobe volumes, normal ranges remain unknown. Using COPDGene data, we developed reference equations for lobar volumes at maximal inflation (total lung capacity [TLC]) and relaxed exhalation (approximating functional residual capacity [FRC]). Linear regression was used to develop race-specific (non-Hispanic white [NHW], African American) reference equations for lobar volumes. Covariates included height and sex. Models were developed in a derivation cohort of 469 subjects with normal pulmonary function and validated in 546 similar subjects. These cohorts were combined to produce final prediction equations, which were applied to 2,191 subjects with old GOLD (Global Initiative for Chronic Obstructive Lung Disease) stage II to IV COPD. In the derivation cohort, women had smaller lobar volumes than men. Height positively correlated with lobar volumes. Adjusting for height, NHWs had larger total lung and lobar volumes at TLC than African Americans; at FRC, NHWs only had larger lower lobes. Age and weight had no effect on lobar volumes at TLC but had small effects at FRC. In subjects with COPD at TLC, upper lobes exceeded 100% of predicted values in GOLD II disease; lower lobes were only inflated to this degree in subjects with GOLD IV disease. At FRC, gas trapping was severe irrespective of disease severity and appeared uniform across the lobes. Reference equations for lobar volumes may be useful in assessing regional lung dysfunction and how it changes in response to pharmacologic therapies and surgical or endoscopic lung volume reduction.

  11. CADDIS Volume 2. Sources, Stressors and Responses: Urbanization - Energy Sources

    Science.gov (United States)

    Introduction to changes in basal energy sources with urbanization, overview of terrestrial leaf litter dynamics in urban streams, overview of how urbanization can affect primary production, respiration, and dissolved organic carbon quantity and quality.

  12. Assessment of the sources of error affecting the quantitative accuracy of SPECT imaging in small animals

    Energy Technology Data Exchange (ETDEWEB)

    Joint Graduate Group in Bioengineering, University of California, San Francisco and University of California, Berkeley; Department of Radiology, University of California; Gullberg, Grant T; Hwang, Andrew B.; Franc, Benjamin L.; Gullberg, Grant T.; Hasegawa, Bruce H.

    2008-02-15

    Small animal SPECT imaging systems have multiple potential applications in biomedical research. Whereas SPECT data are commonly interpreted qualitatively in a clinical setting, the ability to accurately quantify measurements will increase the utility of the SPECT data for laboratory measurements involving small animals. In this work, we assess the effect of photon attenuation, scatter and partial volume errors on the quantitative accuracy of small animal SPECT measurements, first with Monte Carlo simulation and then confirmed with experimental measurements. The simulations modeled the imaging geometry of a commercially available small animal SPECT system. We simulated the imaging of a radioactive source within a cylinder of water, and reconstructed the projection data using iterative reconstruction algorithms. The size of the source and the size of the surrounding cylinder were varied to evaluate the effects of photon attenuation and scatter on quantitative accuracy. We found that photon attenuation can reduce the measured concentration of radioactivity in a volume of interest in the center of a rat-sized cylinder of water by up to 50percent when imaging with iodine-125, and up to 25percent when imaging with technetium-99m. When imaging with iodine-125, the scatter-to-primary ratio can reach up to approximately 30percent, and can cause overestimation of the radioactivity concentration when reconstructing data with attenuation correction. We varied the size of the source to evaluate partial volume errors, which we found to be a strong function of the size of the volume of interest and the spatial resolution. These errors can result in large (>50percent) changes in the measured amount of radioactivity. The simulation results were compared with and found to agree with experimental measurements. The inclusion of attenuation correction in the reconstruction algorithm improved quantitative accuracy. We also found that an improvement of the spatial resolution through the

  13. New developments with H-sources

    International Nuclear Information System (INIS)

    Sherman, Joseph D.; Rouleau, G.

    2002-01-01

    Existing spallation neutron source upgrades, planned spallation neutron sources, and high-energy accelerators for particle physics place demanding requirements on the Hsources. These requirements ask for increased beam currents and duty factor (df) while generally maintaining state-of-the art H' source emittance. A variety of H sources are being developed to address these challenges. These include volume sources with and without the addition of cesium for enhanced He production, increased df cesiated H' Penning and magnetron sources, and cesiated surface converter H- sources. Research on surface films of tantalum metal for enhanced volume H- production is also being studied. Innovative plasma production techniques to address the longer df requirement without sacrificing H- source reliability and liktime will be reviewed. The physical bases, the goals, and perceived challenges will be discussed.

  14. Measurement and simulation of the time-dependent behavior of the UMER source

    International Nuclear Information System (INIS)

    Haber, I.; Feldman, D.; Fiorito, R.; Friedman, A.; Grote, D.P.; Kishek, R.A.; Quinn, B.; Reiser, M.; Rodgers, J.; O'Shea, P.G.; Stratakis, D.; Tian, K.; Vay, J.-L.; Walter, M.

    2007-01-01

    Control of the time-dependent characteristics of the beam pulse, beginning when it is born from the source, is important for obtaining adequate beam intensity on a target. Recent experimental measurements combined with the new mesh-refinement capability in WARP have improved the understanding of time-dependent beam characteristics beginning at the source, as well as the predictive ability of the simulation codes. The University of Maryland Electron Ring (UMER), because of its ease of operation and flexible diagnostics has proved particularly useful for benchmarking WARP by comparing simulation to measurement. One source of significant agreement has been in the ability of three-dimensional WARP simulations to predict the onset of virtual cathode oscillations in the vicinity of the cathode grid in the UMER gun, and the subsequent measurement of the predicted oscillations

  15. 2π absolute measurement research for α-electroplating source covering ZnS(Ag)

    International Nuclear Information System (INIS)

    Zhu Tianxia

    1999-01-01

    2π absolute measurement can be completed after the quantitative deposit (5 +- 1) mg/cm 2 with ZnS(Ag) on surface of the alpha electroplating source. The measuring efficiency is 100%. This method is suitable for both of electroplating ordinary sample and electroplating standard (of reference) source

  16. Fluid Vessel Quantity using Non-Invasive PZT Technology Flight Volume Measurements Under Zero G Analysis

    Science.gov (United States)

    Garofalo, Anthony A.

    2013-01-01

    The purpose of the project is to perform analysis of data using the Systems Engineering Educational Discovery (SEED) program data from 2011 and 2012 Fluid Vessel Quantity using Non-Invasive PZT Technology flight volume measurements under Zero G conditions (parabolic Plane flight data). Also experimental planning and lab work for future sub-orbital experiments to use the NASA PZT technology for fluid volume measurement. Along with conducting data analysis of flight data, I also did a variety of other tasks. I provided the lab with detailed technical drawings, experimented with 3d printers, made changes to the liquid nitrogen skid schematics, and learned how to weld. I also programmed microcontrollers to interact with various sensors and helped with other things going on around the lab.

  17. Intra- and interobserver variability of MRI-based volume measurements of the hippocampus and amygdala using the manual ray-tracing method

    International Nuclear Information System (INIS)

    Achten, E.; Deblaere, K.; Damme, F. van; Kunnen, M.; Wagter, C. de; Boon, P.; Reuck, J. de

    1998-01-01

    We studied the intra- and interobserver variability of volume measurments of the hippocampus (HC) and the amygdala as applied to the detection of HC atrophy in patients with complex partial seizures (CPE), measuring the volumes of the HC and amygdala of 11 normal volunteers and 12 patients with presumed CPE, using the manual ray-tracing method. Two independent observers performed these measurements twice each using home-made software. The intra- and interobserver variability of the absolute volumes and of the normalised left-to-right volume differences (δV) between the HC (δV HC ), the amygdala (δV A ) and the sum of both (δV HCA) were assessed. In our mainly right-handed normals, the right HC and amygdala were on average 0.05 and 0.03 ml larger respectively than on the left. The interobserver variability for volume measurements in normal subjects was 1.80 ml for the HC and 0.82 ml for the amygdala, the intraobserver variability roughly one third of these values. The interobserver variability coefficient in normals was 3.6 % for δV HCA , 4.7 % for δV HC and 7.3 % for δV A . The intraobserver variability coefficient was 3.4 % for δV HCA , 4.2 % for δV HC amd 5.6 % for δV A . The variability in patients was the same for volume differences less than 5 % either side of the interval for normality, but was higher when large volume differences were encountered, is probably due to the lack of thresholding and/or normalisation. Cutoff values for lateralisation with the δV were defined. No intra- or interobserver lateralisation differences were encountered with δV HCA and δV HC . From these observations we conclude that the manual ray-tracing method is a robust method for lateralisation in patients with TLE. Due to its higher variability, this method is less suited to measure absolute volumes. (orig.) (orig.)

  18. Intra- and interobserver variability of MRI-based volume measurements of the hippocampus and amygdala using the manual ray-tracing method

    Energy Technology Data Exchange (ETDEWEB)

    Achten, E.; Deblaere, K.; Damme, F. van; Kunnen, M. [MR Department 1K12, University Hospital Gent (Belgium); Wagter, C. de [Department of Radiotherapy and Nuclear Medicine, University Hospital Gent (Belgium); Boon, P.; Reuck, J. de [Department of Neurology, University Hospital Gent (Belgium)

    1998-09-01

    We studied the intra- and interobserver variability of volume measurments of the hippocampus (HC) and the amygdala as applied to the detection of HC atrophy in patients with complex partial seizures (CPE), measuring the volumes of the HC and amygdala of 11 normal volunteers and 12 patients with presumed CPE, using the manual ray-tracing method. Two independent observers performed these measurements twice each using home-made software. The intra- and interobserver variability of the absolute volumes and of the normalised left-to-right volume differences ({delta}V) between the HC ({delta}V{sub HC}), the amygdala ({delta}V{sub A}) and the sum of both ({delta}V{sub HCA)} were assessed. In our mainly right-handed normals, the right HC and amygdala were on average 0.05 and 0.03 ml larger respectively than on the left. The interobserver variability for volume measurements in normal subjects was 1.80 ml for the HC and 0.82 ml for the amygdala, the intraobserver variability roughly one third of these values. The interobserver variability coefficient in normals was 3.6 % for {delta}V{sub HCA}, 4.7 % for {delta}V{sub HC} and 7.3 % for {delta}V{sub A}. The intraobserver variability coefficient was 3.4 % for {delta}V{sub HCA}, 4.2 % for {delta}V{sub HC} amd 5.6 % for {delta}V{sub A}. The variability in patients was the same for volume differences less than 5 % either side of the interval for normality, but was higher when large volume differences were encountered, is probably due to the lack of thresholding and/or normalisation. Cutoff values for lateralisation with the {delta}V were defined. No intra- or interobserver lateralisation differences were encountered with {delta}V{sub HCA} and {delta}V{sub HC}. From these observations we conclude that the manual ray-tracing method is a robust method for lateralisation in patients with TLE. Due to its higher variability, this method is less suited to measure absolute volumes. (orig.) (orig.) With 2 figs., 7 tabs., 23 refs.

  19. Effects of neutron source type on soil moisture measurement

    Science.gov (United States)

    Irving Goldberg; Norman A. MacGillivray; Robert R. Ziemer

    1967-01-01

    A number of radioisotopes have recently become commercially available as alternatives to radium-225 in moisture gauging devices using alpha-neutron sources for determining soil moisture, for well logging, and for other industrial applications in which hydrogenous materials are measured.

  20. Measurement of the activity of an artificial neutrino source based on 37Ar

    International Nuclear Information System (INIS)

    Abdurashitov, D. N.; Veretenkin, E. P.; Gavrin, V. N.; Gorbachev, V. V.; Ibragimova, T. V.; Kalikhov, A. V.; Mirmov, I. N.; Shikhin, A. A.; Yants, V. E.; Barsanov, V. I.; Dzhanelidze, A. A.; Zlokazov, S. B.; Markov, S. Yu.; Shakirov, Z. N.; Cleveland, B. T.

    2007-01-01

    The activity of an artificial neutrino source based on 37 Ar was measured by a specially developed method of directly counting 37 Ar decays in a proportional counter. This source was used to irradiate the target of the SAGE radiochemical gallium-germanium neutrino telescope at the Baksan Neutrino Observatory (Institute for Nuclear Research, Russian Academy of Sciences, Moscow), whereupon the measurements were performed at the Institute of Reactor Materials (Zarechny, Sverdlovsk oblast, Russia). The method used to prepare gaseous samples for measurements in proportional counters and the counting procedure are described. The measured activity of the 37 Ar neutrino source is 405.1 ± 3.7 kCi (corrected for decays that occurred within the period between the instant of activity measurement and the commencement of the irradiation of Ga target at 04:00 Moscow time, 30.04.2004)

  1. Left ventricular volume measurements with free breathing respiratory self-gated 3-dimensional golden angle radial whole-heart cine imaging - Feasibility and reproducibility.

    Science.gov (United States)

    Holst, Karen; Ugander, Martin; Sigfridsson, Andreas

    2017-11-01

    To develop and evaluate a free breathing respiratory self-gated isotropic resolution technique for left ventricular (LV) volume measurements. A 3D radial trajectory with double golden-angle ordering was used for free-running data acquisition during free breathing in 9 healthy volunteers. A respiratory self-gating signal was extracted from the center of k-space and used with the electrocardiogram to bin all data into 3 respiratory and 25 cardiac phases. 3D image volumes were reconstructed and the LV endocardial border was segmented. LV volume measurements and reproducibility from 3D free breathing cine were compared to conventional 2D breath-held cine. No difference was found between 3D free breathing cine and 2D breath-held cine with regards to LV ejection fraction, stroke volume, end-systolic volume and end-diastolic volume (Pcine and 2D breath-held cine (Pcine and conventional 2D breath-held cine showed similar values and test-retest repeatability for LV volumes in healthy volunteers. 3D free breathing cine enabled retrospective sorting and arbitrary angulation of isotropic data, and could correctly measure LV volumes during free breathing acquisition. Copyright © 2017 Elsevier Inc. All rights reserved.

  2. Metrological tests of a 200 L calibration source for HPGE detector systems for assay of radioactive waste drums

    International Nuclear Information System (INIS)

    Boshkova, T.; Mitev, K.

    2016-01-01

    In this work we present test procedures, approval criteria and results from two metrological inspections of a certified large volume "1"5"2Eu source (drum about 200 L) intended for calibration of HPGe gamma assay systems used for activity measurement of radioactive waste drums. The aim of the inspections was to prove the stability of the calibration source during its working life. The large volume source was designed and produced in 2007. It consists of 448 identical sealed radioactive sources (modules) apportioned in 32 transparent plastic tubes which were placed in a wooden matrix which filled the drum. During the inspections the modules were subjected to tests for verification of their certified characteristics. The results show a perfect compliance with the NIST basic guidelines for the properties of a radioactive certified reference material (CRM) and demonstrate the stability of the large volume CRM-drum after 7 years of operation. - Highlights: • Large (200 L) volume drum source designed, produced and certified as CRM in 2007. • Source contains 448 identical sealed radioactive "1"5"2Eu sources (modules). • Two metrological inspections in 2011 and 2014. • No statistically significant changes of the certified characteristics over time. • Stable calibration source for HPGe-gamma radioactive waste assay systems.

  3. 3H-dextran method for measurements of the blood volume in the rat choroid

    International Nuclear Information System (INIS)

    Matsusaka, Toshihiko; Morimoto, Kazuhiro; Kikkawa, Yoshizo.

    1980-01-01

    A new method was developed using 3 H-dextran for measuring the blood volume in the choroid. Under pentobarbital-anesthesia, albino rats weighing 200 grams were perfused through the left ventricle with a 2.5 percent glutaraldehyde solution containing the radioactive dextran. The procedure allowed exchange of the choroidal blood with the 3 H-dextran solution with a simultaneous fixation of the choroid. The blood volume in the choroid was calculated from the radioactivity count, which is estimated to be 1.690 x 10 -4 ml per mg wet weight and 5.070 x 10 -4 ml per mg dry weight. Epinephrine subconjunctivally injected diminished the blood volume in the choroid by 68 percent. Pretreatment with lidocaine almost nullified the effect of epinephrine. Applicability of this method to the analytical study of the choroidal circulation is discussed. (author)

  4. Measurement-device-independent quantum communication with an untrusted source

    Science.gov (United States)

    Xu, Feihu

    2015-07-01

    Measurement-device-independent quantum key distribution (MDI-QKD) can provide enhanced security compared to traditional QKD, and it constitutes an important framework for a quantum network with an untrusted network server. Still, a key assumption in MDI-QKD is that the sources are trusted. We propose here a MDI quantum network with a single untrusted source. We have derived a complete proof of the unconditional security of MDI-QKD with an untrusted source. Using simulations, we have considered various real-life imperfections in its implementation, and the simulation results show that MDI-QKD with an untrusted source provides a key generation rate that is close to the rate of initial MDI-QKD in the asymptotic setting. Our work proves the feasibility of the realization of a quantum network. The network users need only low-cost modulation devices, and they can share both an expensive detector and a complicated laser provided by an untrusted network server.

  5. Optimized spectroscopic scheme for enhanced precision CO measurements with applications to urban source attribution

    Science.gov (United States)

    Nottrott, A.; Hoffnagle, J.; Farinas, A.; Rella, C.

    2014-12-01

    Carbon monoxide (CO) is an urban pollutant generated by internal combustion engines which contributes to the formation of ground level ozone (smog). CO is also an excellent tracer for emissions from mobile combustion sources. In this work we present an optimized spectroscopic sampling scheme that enables enhanced precision CO measurements. The scheme was implemented on the Picarro G2401 Cavity Ring-Down Spectroscopy (CRDS) analyzer which measures CO2, CO, CH4 and H2O at 0.2 Hz. The optimized scheme improved the raw precision of CO measurements by 40% from 5 ppb to 3 ppb. Correlations of measured CO2, CO, CH4 and H2O from an urban tower were partitioned by wind direction and combined with a concentration footprint model for source attribution. The application of a concentration footprint for source attribution has several advantages. The upwind extent of the concentration footprint for a given sensor is much larger than the flux footprint. Measurements of mean concentration at the sensor location can be used to estimate source strength from a concentration footprint, while measurements of the vertical concentration flux are necessary to determine source strength from the flux footprint. Direct measurement of vertical concentration flux requires high frequency temporal sampling and increases the cost and complexity of the measurement system.

  6. Reliability of fetal cardiac volumetry using spatiotemporal image correlation: assessment of in-vivo and in-vitro measurements

    NARCIS (Netherlands)

    Uittenbogaard, L.B.; Haak, M.C.; Tromp, C.H.N.; Terwee, C.B.; van Vugt, J.M.G.

    2010-01-01

    Objective To assess the reliability of measurement of fetal cardiac ventricular volume, stroke volume, and ejection fraction with four-dimensional ultrasound using spatiotemporal image correlation (STIC). Methods Volume datasets were collected from two sources: 24 from fetuses over a range of

  7. Experience and problems of the automated measuring and sorting of sealed radiation sources

    International Nuclear Information System (INIS)

    Shmidt, G.

    1979-01-01

    It has been shown that with the help of a serial device for samples changing and a mini-computer with a suitable software it is possible to organize the radioactivity measuring and sorting of sealed gamma-sources with activity in the microcuri region. Application of the computer permits to rise accuracy of the data on the radiation sources radioactivity, sorted according to the preset activity level groups and, in the casa of necessity, to perform the activity measurements with lower error. The method listed, gives the working-time economy of nearly 4 hours in measuring and sorting of some 500 sealed radiation sources [ru

  8. Robust, accurate, and non-contacting vibration measurement systems: Supplemental appendices presenting comparison measurements of the robust laser interferometer and typical accelerometer systems. Volume 2

    International Nuclear Information System (INIS)

    Goodenow, T.C.; Shipman, R.L.; Holland, H.M.

    1995-06-01

    Epoch Engineering, Incorporated (EEI) has completed a series of vibration measurements comparing their newly-developed Robust Laser Interferometer (RLI) with accelerometer-based instrumentation systems. EEI has successfully demonstrated, on several pieces of commonplace machinery, that non-contact, line-of-sight measurements are practical and yield results equal to or, in some cases, better than customary field implementations of accelerometers. The demonstration included analysis and comparison of such phenomena as nonlinearity, transverse sensitivity, harmonics, and signal-to-noise ratio. Fast Fourier Transformations were performed on the accelerometer and the laser system outputs to provide a comparison basis. The RLI was demonstrated, within the limits o the task, to be a viable, line-of-sight, non-contact alternative to accelerometer systems. Several different kinds of machinery were instrumented and. compared, including a small pump, a gear-driven cement mixer, a rotor kit, and two small fans. Known machinery vibration sources were verified and RLI system output file formats were verified to be compatible with commercial computer programs used for vibration monitoring and trend analysis. The RLI was also observed to be less subject to electromagnetic interference (EMI) and more capable at very low frequencies. This document, Volume 2, provides the appendices to this report

  9. Refurbishing tritium contaminated ion sources

    International Nuclear Information System (INIS)

    Wright, K.E.; Carnevale, R.H.; McCormack, B.E.; Stevenson, T.; Halle, A. von

    1995-01-01

    Extended tritium experimentation on TFTR has necessitated refurbishing Neutral Beam Long Pulse Ion Sources (LPIS) which developed operational difficulties, both in the TFTR Test Cell and later, in the NB Source Refurbishment Shop. Shipping contaminated sources off-site for repair was not permissible from a transport and safety perspective. Therefore, the NB source repair facility was upgraded by relocating fixtures, tooling, test apparatus, and three-axis coordinate measuring equipment; purchasing and fabricating fume hoods; installing exhaust vents; and providing a controlled negative pressure environment in the source degreaser/decon area. Appropriate air flow monitors, pressure indicators, tritium detectors and safety alarms were also included. The effectiveness of various decontamination methods was explored while the activation was monitored. Procedures and methods were developed to permit complete disassembly and rebuild of an ion source while continuously exhausting the internal volume to the TFTR Stack to avoid concentrations of tritium from outgassing and minimize personnel exposure. This paper presents upgrades made to the LPIS repair facility, various repair tasks performed, and discusses the effectiveness of the decontamination processes utilized

  10. Test-retest reliability of automated whole body and compartmental muscle volume measurements on a wide bore 3T MR system.

    Science.gov (United States)

    Thomas, Marianna S; Newman, David; Leinhard, Olof Dahlqvist; Kasmai, Bahman; Greenwood, Richard; Malcolm, Paul N; Karlsson, Anette; Rosander, Johannes; Borga, Magnus; Toms, Andoni P

    2014-09-01

    To measure the test-retest reproducibility of an automated system for quantifying whole body and compartmental muscle volumes using wide bore 3 T MRI. Thirty volunteers stratified by body mass index underwent whole body 3 T MRI, two-point Dixon sequences, on two separate occasions. Water-fat separation was performed, with automated segmentation of whole body, torso, upper and lower leg volumes, and manually segmented lower leg muscle volumes. Mean automated total body muscle volume was 19·32 L (SD9·1) and 19·28 L (SD9·12) for first and second acquisitions (Intraclass correlation coefficient (ICC) = 1·0, 95% level of agreement -0·32-0·2 L). ICC for all automated test-retest muscle volumes were almost perfect (0·99-1·0) with 95% levels of agreement 1.8-6.6% of mean volume. Automated muscle volume measurements correlate closely with manual quantification (right lower leg: manual 1·68 L (2SD0·6) compared to automated 1·64 L (2SD 0·6), left lower leg: manual 1·69 L (2SD 0·64) compared to automated 1·63 L (SD0·61), correlation coefficients for automated and manual segmentation were 0·94-0·96). Fully automated whole body and compartmental muscle volume quantification can be achieved rapidly on a 3 T wide bore system with very low margins of error, excellent test-retest reliability and excellent correlation to manual segmentation in the lower leg. Sarcopaenia is an important reversible complication of a number of diseases. Manual quantification of muscle volume is time-consuming and expensive. Muscles can be imaged using in and out of phase MRI. Automated atlas-based segmentation can identify muscle groups. Automated muscle volume segmentation is reproducible and can replace manual measurements.

  11. A discriminative structural similarity measure and its application to video-volume registration for endoscope three-dimensional motion tracking.

    Science.gov (United States)

    Luo, Xiongbiao; Mori, Kensaku

    2014-06-01

    Endoscope 3-D motion tracking, which seeks to synchronize pre- and intra-operative images in endoscopic interventions, is usually performed as video-volume registration that optimizes the similarity between endoscopic video and pre-operative images. The tracking performance, in turn, depends significantly on whether a similarity measure can successfully characterize the difference between video sequences and volume rendering images driven by pre-operative images. The paper proposes a discriminative structural similarity measure, which uses the degradation of structural information and takes image correlation or structure, luminance, and contrast into consideration, to boost video-volume registration. By applying the proposed similarity measure to endoscope tracking, it was demonstrated to be more accurate and robust than several available similarity measures, e.g., local normalized cross correlation, normalized mutual information, modified mean square error, or normalized sum squared difference. Based on clinical data evaluation, the tracking error was reduced significantly from at least 14.6 mm to 4.5 mm. The processing time was accelerated more than 30 frames per second using graphics processing unit.

  12. Timing jitter measurements at the SLC electron source

    International Nuclear Information System (INIS)

    Sodja, J.; Browne, M.J.; Clendenin, J.E.

    1989-03-01

    The SLC thermionic gun and electron source produce a beam of up to 15 /times/ 10 10 /sub e//minus/ in a single S-band bunch. A 170 keV, 2 ns FWHM pulse out of the gun is compressed by means of two subharmonic buncher cavities followed by an S-band buncher and a standard SLAC accelerating section. Ceramic gaps in the beam pipe at the output of the gun allow a measure of the beam intensity and timing. A measurement at these gaps of the timing jitter, with a resolution of <10 ps, is described. 3 refs., 5 figs

  13. Brain tissues volume measurements from 2D MRI using parametric approach

    Science.gov (United States)

    L'vov, A. A.; Toropova, O. A.; Litovka, Yu. V.

    2018-04-01

    The purpose of the paper is to propose a fully automated method of volume assessment of structures within human brain. Our statistical approach uses maximum interdependency principle for decision making process of measurements consistency and unequal observations. Detecting outliers performed using maximum normalized residual test. We propose a statistical model which utilizes knowledge of tissues distribution in human brain and applies partial data restoration for precision improvement. The approach proposes completed computationally efficient and independent from segmentation algorithm used in the application.

  14. High concentration tritium gas measurement with small volume ionization chambers for fusion fuel gas monitors

    International Nuclear Information System (INIS)

    Uda, Tatsuhiko; Okuno, Kenji; Matsuda, Yuji; Naruse, Yuji

    1991-01-01

    To apply ionization chambers to fusion fuel gas processing systems, high concentration tritium gas was experimentally measured with small volume 0.16 and 21.6 cm 3 ionization chambers. From plateau curves, the optimum electric field strength was obtained as 100∼200 V/cm. Detection efficiency was confirmed as dependent on the ionization ability of the filled gas, and moreover on its stopping power, because when the range of the β-rays was shortened, the probability of energy loss by collisions with the electrode and chamber wall increased. Loss of ions by recombination was prevented by using a small volume ionization chamber. For example the 0.16 cm 3 ionization chamber gave measurement with linearity to above 40% tritium gas. After the tritium gas measurements, the concentration levels inside the chamber were estimated from their memory currents. Although more than 1/4,000 of the maximum, current was observed as a memory effect, the smaller ionization chamber gave a smaller memory effect. (author)

  15. Volume fraction prediction in biphasic flow using nuclear technique and artificial neural network

    International Nuclear Information System (INIS)

    Salgado, Cesar M.; Brandao, Luis E.B.

    2015-01-01

    The volume fraction is one of the most important parameters used to characterize air-liquid two-phase flows. It is a physical value to determine other parameters, such as the phase's densities and to determine the flow rate of each phase. These parameters are important to predict the flow pattern and to determine a mathematical model for the system. To study, for example, heat transfer and pressure drop. This work presents a methodology for volume fractions prediction in water-gas stratified flow regime using the nuclear technique and artificial intelligence. The volume fractions calculate in biphasic flow systems is complex and the analysis by means of analytical equations becomes very difficult. The approach is based on gamma-ray pulse height distributions pattern recognition by means of the artificial neural network. The detection system uses appropriate broad beam geometry, comprised of a ( 137 Cs) energy gamma-ray source and a NaI(Tl) scintillation detector in order measure transmitted beam whose the counts rates are influenced by the phases composition. These distributions are directly used by the network without any parameterization of the measured signal. The ideal and static theoretical models for stratified regime have been developed using MCNP-X code, which was used to provide training, test and validation data for the network. The detector also was modeled with this code and the results were compared to experimental photopeak efficiency measurements of radiation sources. The proposed network could obtain with satisfactory prediction of the volume fraction in water-gas system, demonstrating to be a promising approach for this purpose. (author)

  16. Volume fraction prediction in biphasic flow using nuclear technique and artificial neural network

    Energy Technology Data Exchange (ETDEWEB)

    Salgado, Cesar M.; Brandao, Luis E.B., E-mail: otero@ien.gov.br, E-mail: brandao@ien.gov.br [Instituto de Engenharia Nuclear (IEN/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2015-07-01

    The volume fraction is one of the most important parameters used to characterize air-liquid two-phase flows. It is a physical value to determine other parameters, such as the phase's densities and to determine the flow rate of each phase. These parameters are important to predict the flow pattern and to determine a mathematical model for the system. To study, for example, heat transfer and pressure drop. This work presents a methodology for volume fractions prediction in water-gas stratified flow regime using the nuclear technique and artificial intelligence. The volume fractions calculate in biphasic flow systems is complex and the analysis by means of analytical equations becomes very difficult. The approach is based on gamma-ray pulse height distributions pattern recognition by means of the artificial neural network. The detection system uses appropriate broad beam geometry, comprised of a ({sup 137}Cs) energy gamma-ray source and a NaI(Tl) scintillation detector in order measure transmitted beam whose the counts rates are influenced by the phases composition. These distributions are directly used by the network without any parameterization of the measured signal. The ideal and static theoretical models for stratified regime have been developed using MCNP-X code, which was used to provide training, test and validation data for the network. The detector also was modeled with this code and the results were compared to experimental photopeak efficiency measurements of radiation sources. The proposed network could obtain with satisfactory prediction of the volume fraction in water-gas system, demonstrating to be a promising approach for this purpose. (author)

  17. Design parameters and source terms: Volume 2, Source terms: Revision 0

    International Nuclear Information System (INIS)

    1987-10-01

    The Design Parameters and Source Terms Document was prepared in accordance with DOE request and to provide data for the environmental impact study to be performed in the future for the Deaf Smith County, Texas site for a nuclear waste repository in salt. This document updates a previous unpublished report by Stearns Catalytic Corporation (SCC), entitled ''Design Parameters and Source Terms for a Two-Phase Repository Salt,'' 1985, to the level of the Site Characterization Plan - Conceptual Design Report. The previous unpublished SCC Study identifies the data needs for the Environmental Assessment effort for seven possible Salt Repository sites. 2 tabs

  18. Measurement of average density and relative volumes in a dispersed two-phase fluid

    Science.gov (United States)

    Sreepada, Sastry R.; Rippel, Robert R.

    1992-01-01

    An apparatus and a method are disclosed for measuring the average density and relative volumes in an essentially transparent, dispersed two-phase fluid. A laser beam with a diameter no greater than 1% of the diameter of the bubbles, droplets, or particles of the dispersed phase is directed onto a diffraction grating. A single-order component of the diffracted beam is directed through the two-phase fluid and its refraction is measured. Preferably, the refracted beam exiting the fluid is incident upon a optical filter with linearly varing optical density and the intensity of the filtered beam is measured. The invention can be combined with other laser-based measurement systems, e.g., laser doppler anemometry.

  19. Interferometry with flexible point source array for measuring complex freeform surface and its design algorithm

    Science.gov (United States)

    Li, Jia; Shen, Hua; Zhu, Rihong; Gao, Jinming; Sun, Yue; Wang, Jinsong; Li, Bo

    2018-06-01

    The precision of the measurements of aspheric and freeform surfaces remains the primary factor restrict their manufacture and application. One effective means of measuring such surfaces involves using reference or probe beams with angle modulation, such as tilted-wave-interferometer (TWI). It is necessary to improve the measurement efficiency by obtaining the optimum point source array for different pieces before TWI measurements. For purpose of forming a point source array based on the gradients of different surfaces under test, we established a mathematical model describing the relationship between the point source array and the test surface. However, the optimal point sources are irregularly distributed. In order to achieve a flexible point source array according to the gradient of test surface, a novel interference setup using fiber array is proposed in which every point source can be independently controlled on and off. Simulations and the actual measurement examples of two different surfaces are given in this paper to verify the mathematical model. Finally, we performed an experiment of testing an off-axis ellipsoidal surface that proved the validity of the proposed interference system.

  20. Heat capacity measurements of sub-nanoliter volumes of liquids using bimaterial microchannel cantilevers

    Science.gov (United States)

    Khan, M. F.; Miriyala, N.; Lee, J.; Hassanpourfard, M.; Kumar, A.; Thundat, T.

    2016-05-01

    Lab-on-a-Chip compatible techniques for thermal characterization of miniaturized volumes of liquid analytes are necessary in applications such as protein blotting, DNA melting, and drug development, where samples are either rare or volume-limited. We developed a closed-chamber calorimeter based on a bimaterial microchannel cantilever (BMC) for sub-nanoliter level thermal analysis. When the liquid-filled BMC is irradiated with infrared (IR) light at a specific wavelength, the IR absorption by the liquid analyte results in localized heat generation and the subsequent deflection of the BMC, due to a thermal expansion mismatch between the constituent materials. The time constant of the deflection, which is dependent upon the heat capacity of the liquid analyte, can be directly measured by recording the time-dependent bending of the BMC. We have used the BMC to quantitatively measure the heat capacity of five volatile organic compounds. With a deflection noise level of ˜10 nm and a signal-to-noise ratio of 68:1, the BMC offers a sensitivity of 30.5 ms/(J g-1 K-1) and a resolution of 23 mJ/(g K) for ˜150 pl liquid for heat capacity measurements. This technique can be used for small-scale thermal characterization of different chemical and biological samples.

  1. Source profiles of volatile organic compounds (VOCs) measured in China: Part I

    Science.gov (United States)

    Liu, Ying; Shao, Min; Fu, Linlin; Lu, Sihua; Zeng, Limin; Tang, Dagang

    The profiles of major volatile organic compound (VOC) sources in China, including vehicle exhaust, gasoline vapor, paint, asphalt, industrial and residential coal burning, biomass burning, and the petrochemical industry, were experimentally determined. Source samples were taken using a dilution chamber for mobile and stationary sources, biomass burning in an actual Chinese farmer's house, and ambient air in a petrochemical industrial area. The concentrations of 92 VOC species were quantified using canister sampling and a gas chromatography-flame ionization detection/mass spectrometry system, and VOC source profiles were developed for source apportionment of VOCs in the Pearl River Delta region. Based on the measurement of source profiles, possible tracers for various emission sources were identified; e.g., 2-methylpentane and 1,3-butadiene could be used as tracers for vehicle exhaust; the characteristic compounds of architectural coating were aromatics such as toluene and m, p-xylene; the light hydrocarbons, namely n-butane, trans-2-butene, and n-pentane, dominated the composition of gasoline vapor; and n-nonane, n-decane, and n-undecane were found to be typical of diesel vapor and asphalt application processes. As different emission sources are characterized by overlapping VOC species, the ratio of possible VOC tracers could be used to assess the contribution of various sources. The ratios between n-butane and isobutane, 1,3-butadiene and isoprene, and the ratios of aromatics (e.g., toluene to benzene and ethylbenzene to m, p-xylene) in the measured sources were compared.

  2. Energy efficiency of the CTX magnetized coaxial plasma source

    International Nuclear Information System (INIS)

    Fernandez, J.C.; Barnes, C.W.; Jarboe, T.R.; Knox, S.O.; Platts, D.A.; McKenna, K.F.

    1985-01-01

    The energy efficiency of the CTX coaxial plasma source in creating spheromaks is determined experimentally to be in agreement with the theoretical prediction of lambda/sub sp//lambda/sub g/, where del x B = lambda/sub sp/ B in the spheromak, and lambda/sub g/ identical with μ 0 I/sub g//phi/sub g/ with I/sub g/ the source current and phi/sub g/ the magnetic flux through either source electrode. This is shown to be equivalent to magnetic helicity conservation. The spheromak impurity radiation was measured using an absolutely calibrated single chord bolometer system. The theoretical efficiency is within the experimental uncertainty of the ratio of spheromak radiated energy to source input energy in a group of ''dirty'' discharges. But the radiation measurement uncertainty is too large to determine whether a substantial part of the excess source energy not used in the production of spheromak magnetic energy is radiated from the spheromak volume

  3. A comparison between Philips and Tomtec for left ventricular deformation and volume measurements in neonatal intensive care patients.

    Science.gov (United States)

    de Waal, Koert; Phad, Nilkant

    2018-03-01

    Two-dimensional speckle tracking echocardiography is an emerging technique for analyzing cardiac function in newborns. Strain is a highly reliable and reproducible parameter, and reference values have been established for term and preterm newborns. Its implementation into clinical practice has been slow, partly due to lack of inter-vendor consistency. Our aim was to compare recent versions of Philips and Tomtec speckle tracking software for deformation and semiautomated volume and area measurements in neonatal intensive care patients. Longitudinal and circumferential deformation and cavity dimensions (volume, area) were determined off line from apical and short-axis images in 50 consecutive newborns with a median birthweight of 760 g (range 460-3200 g). Absolute mean endocardial global longitudinal strain measurements were similar between vendors, but with wide limits of agreement (Philips -18.9 [2.1]%, Tomtec -18.6 [2.5]%, bias -0.3 [1.7]%, and limits of agreement -3.6%-3.1%). Longitudinal strain rate and circumferential measurements showed poor correlation. All volume and area measurements correlated well between the vendors, but with significant bias. Global longitudinal strain measurements compared well between vendors but wide limits of agreement, suggesting that longitudinal measurements are preferred using similar hardware and software. © 2017, Wiley Periodicals, Inc.

  4. Solar engineering 1995: Proceedings. Volume 1

    International Nuclear Information System (INIS)

    Stine, W.B.; Tanaka, Tadayoshi; Claridge, D.E.

    1995-01-01

    This is Volume 1 of the papers presented at the 1995 ASME/JSME/JSES International Solar Energy Conference. The topics of the papers include wind energy, heat pump performance, ground source and solar chemical heat pumps, analysis of measured building energy data, thermal storage, system modeling of buildings, evaluation of the Federal Building energy Efficiency program, sustainable projects, bioconversion, solar chemistry, solar detoxification innovative concepts and industrial applications, solar thermal power systems, DISH/engine power systems, power towers, solar thermal power advanced development, and solar thermal process heating and cooling

  5. The Einstein Observatory catalog of IPC x ray sources. Volume 7E: Right ascension range 20h 00m to 23h 59m

    Science.gov (United States)

    Harris, D. E.; Forman, W.; Gioia, I. M.; Hale, J. A.; Harnden, F. R., Jr.; Jones, C.; Karakashian, T.; Maccacaro, T.; Mcsweeney, J. D.; Primini, F. A.

    1993-01-01

    The Einstein Observatory (HEAO-2, launched November 13, 1978) achieved radically improved sensitivity over previous x-ray missions through the use of focusing optics which simultaneously afforded greatly reduced background and produced true images. During its 2.5-yr mission, the Einstein X-Ray Telescope was pointed toward some 5,000 celestial targets, most of which were detected, and discovered several thousand additional 'serendipitous' sources in the observed fields. This catalog contains contour diagrams and source data, obtained with the imaging proportional counter in the 0.16 to 3.5 keV energy band, and describes methods for recovering upper limits for any sky position within the observed images. The main catalog consists of six volumes (numbered 2 through 7) of right ascension ordered pages, each containing data for one observation. Along with the primary documentation describing how the catalog was constructed, volume 1 contains a complete source list, results for merged fields, a reference system to published papers, and data useful for calculating upper limits and fluxes.

  6. The Einstein Observatory catalog of IPC x ray sources. Volume 2E: Right ascension range 00h 00m to 03h 59m

    Science.gov (United States)

    Harris, D. E.; Forman, W.; Gioia, I. M.; Hale, J. A.; Harnden, F. R., Jr.; Jones, C.; Karakashian, T.; Maccacaro, T.; Mcsweeney, J. D.; Primini, F. A.

    1993-01-01

    The Einstein Observatory (HEAO-2, launched November 13, 1978) achieved radically improved sensitivity over previous x-ray missions through the use of focusing optics which simultaneously afforded greatly reduced background and produced true images. During its 2.5-yr mission, the Einstein X-Ray Telescope was pointed toward some 5,000 celestial targets, most of which were detected, and discovered several thousand additional 'serendipitous' sources in the observed fields. This catalog contains contour diagrams and source data, obtained with the imaging proportional counter in the 0.16 to 3.5 keV energy band, and describes methods for recovering upper limits for any sky position within the observed images. The main catalog consists of six volumes (numbered 2 through 7) of right ascension ordered pages, each containing data for one observation. Along with the primary documentation describing how the catalog was constructed, volume 1 contains a complete source list, results for merged fields, a reference system to published papers and data useful for calculating upper limits and fluxes.

  7. The Einstein Observatory catalog of IPC x ray sources. Volume 5E: Right ascension range 12h 00m to 15h 59m

    Science.gov (United States)

    Harris, D. E.; Forman, W.; Gioia, I. M.; Hale, J. A.; Harnden, F. R., Jr.; Jones, C.; Karakashian, T.; Maccacaro, T.; Mcsweeney, J. D.; Primini, F. A.

    1993-01-01

    The Einstein Observatory (HEAO-2, launched November 13, 1978) achieved radically improved sensitivity over previous x-ray missions through the use of focusing optics, which simultaneously afforded greatly reduced background and produced true images. During its 2.5-yr mission, the Einstein X-Ray Telescope was pointed toward some 5,000 celestial targets, most of which were detected, and discovered several thousand additional 'serendipitous' sources in the observed fields. This catalog contains contour diagrams and source data, obtained with the imaging proportional counter in the 0.16 to 3.5 keV energy band, and describes methods for recovering upper limits for any sky position within the observed images. The main catalog consists of six volumes (numbered 2 through 7) of right ascension ordered pages, each containing data for one observation. Along with the primary documentation describing how the catalog was constructed, volume 1 contains a complete source list, results for merged fields, a reference system to published papers, and data useful for calculating upper limits and fluxes.

  8. The Einstein Observatory catalog of IPC x ray sources. Volume 3E: Right ascension range 04h 00m to 07h 59m

    Science.gov (United States)

    Harris, D. E.; Forman, W.; Gioia, I. M.; Hale, J. A.; Harnden, F. R., Jr.; Jones, C.; Karakashian, T.; Maccacaro, T.; Mcsweeney, J. D.; Primini, F. A.

    1993-01-01

    The Einstein Observatory (HEAO-2, launched November 13, 1978) achieved radically improved sensitivity over previous x-ray missions through the use of focusing optics which simultaneously afforded greatly reduced background and produced true images. During its 2.5-yr mission, the Einstein X-Ray Telescope was pointed toward some 5,000 celestial targets, most of which were detected, and discovered several thousand additional 'serendipitous' sources in the observed fields. This catalog contains contour diagrams and source data, obtained with the imaging proportional counter in the 0.16 to 3.5 keV energy band, and describes methods for recovering upper limits for any sky position within the observed images. The main catalog consists of six volumes (numbered 2 through 7) of right ascension ordered pages, each containing data for one observation. Along with the primary documentation describing how the catalog was constructed, volume 1 contains a complete source list, results for merged fields, a reference system to published papers and data useful for calculating upper limits and fluxes.

  9. The Einstein Observatory catalog of IPC x ray sources. Volume 6E: Right ascension range 16h 00m to 19h 59m

    Science.gov (United States)

    Harris, D. E.; Forman, W.; Gioia, I. M.; Hale, J. A.; Harnden, F. R., Jr.; Jones, C.; Karakashian, T.; Maccacaro, T.; Mcsweeney, J. D.; Primini, F. A.

    1993-01-01

    The Einstein Observatory (HEAO-2 launched November 13, 1978) achieved radically improved sensitivity over previous x-ray missions through the use of focusing optics, which simultaneously afforded greatly reduced background and produced true images. During its 2.5-yr mission, the Einstein X-Ray Telescope was pointed toward some 5,000 celestial targets, most of which were detected, and discovered several thousand additional 'serendipitous' sources in the observed fields. This catalog contains contour diagrams and source data, obtained with the imaging proportional counter in the 0.16 to 3.5 keV energy band, and describes methods for recovering upper limits for any sky position within the observed images. The main catalog consists of six volumes (numbered 2 through 7) of right ascension ordered pages, each containing data for one observation. Along with the primary documentation describing how the catalog was constructed, volume 1 contains a complete source list, results for merged fields, a reference system to published papers, and data useful for calculating upper limits and fluxes.

  10. The Einstein Observatory catalog of IPC x ray sources. Volume 4E: Right ascension range 08h 00m to 11h 59m

    Science.gov (United States)

    Harris, D. E.; Forman, W.; Gioia, I. M.; Hale, J. A.; Harnden, F. R., Jr.; Jones, C.; Karakashian, T.; Maccacaro, T.; Mcsweeney, J. D.; Primini, F. A.

    1993-01-01

    The Einstein Observatory (HEAO-2, launched November 13, 1978) achieved radically improved sensitivity over previous x-ray missions through the use of focusing optics which simultaneously afforded greatly reduced background and produced true images. During its 2.5-yr mission, the Einstein X-Ray Telescope was pointed toward some 5,000 celestial targets, most of which were detected, and discovered several thousand additional 'serendipitous' sources in the observed fields. This catalog contains contour diagrams and source data, obtained with the imaging proportional counter in the 0.16 to 3.5 keV energy band, and describes methods for recovering upper limits for any sky position within the observed images, The main catalog consists of six volumes (numbered 2 through 7) of right ascension ordered pages, each containing data for one observation. Along with the primary documentaion describing how the catalog was constructed, volume 1 contains a complete source list, results for merged fields, a reference system to published papers, and data useful for calculating upper limits and fluxes.

  11. Dilatometric measurement of the partial molar volume of water sorbed to durum wheat flour.

    Science.gov (United States)

    Hasegawa, Ayako; Ogawa, Takenobu; Adachi, Shuji

    2013-01-01

    Moisture sorption isotherms were measured at 25 °C for untreated, dry-heated and pre-gelatinized durum wheat flour samples. The isotherms could be expressed by the Guggenheim-Anderson-de Boer equation. The amount of water sorbed to the untreated flour was highest for low water activity, with water sorbed to the pre-gelatinized and dry-heated flour samples following. The dry-heated and pregelatinized flour samples exhibited the same dependence of the moisture content on the partial molar volume of water at 25 °C as the untreated flour. The partial molar volume of water was ca. 9 cm(3)/mol at a moisture content of 0.03 kg-H2O/kg-d.m. The volume increased with increasing moisture content, and reached a constant value of ca. 17.5 cm(3)/mol at a moisture content of 0.2 kg-H2O/kg-d.m. or higher.

  12. A portable measurement system for subcriticality measurements by the Cf-source-driven neutron noise analysis method

    International Nuclear Information System (INIS)

    Mihalczo, J.T.; Ragan, G.E.; Blakeman, E.D.

    1987-01-01

    A portable measurement system consisting of a personal computer used as a Fourier analyzer and three detection channels (with associated electronics that provide the signals to analog-to-digital (A/D) convertors) has been assembled to measure subcriticality by the 252 Cf-source-driven neutron noise analysis method. 8 refs

  13. Role of cerebral blood volume changes in brain specific-gravity measurements

    International Nuclear Information System (INIS)

    Picozzi, P.; Todd, N.V.; Crockard, A.H.

    1985-01-01

    Cerebral blood volume (CBV) was calculated in gerbils from specific-gravity (SG) changes between normal and saline-perfused brains. Furthermore, changes in CBV were investigated during ischemia using carbon-14-labeled dextran (MW 70,000) as an intravascular marker. Both data were used to evaluate the possible error due to a change in CBV on the measurement of ischemic brain edema by the SG method. The methodological error found was 0.0004 for a 100% CBV change. This error is insignificant, being less than the standard deviation in the SG measured for the gerbil cortex. Thus, CBV changes are not responsible for the SG variations observed during the first phase of ischemia. These variations are better explained as an increase of brain water content during ischemia

  14. Complementarity between innovation knowledge sources: Does the innovation performance measure matter?

    Directory of Open Access Journals (Sweden)

    Ana Mª Serrano-Bedia

    2018-01-01

    Full Text Available We analyse complementarity between different knowledge sources (internal, external and/or cooperation employing a wide range of innovation performance measures (product, process, organizational, and commercial. The empirical study uses 2014 Spanish CIS data and studies complementarities by performing conditional complementarity/substitutability tests. The results show evidence of conditional complementarity in product innovation performance between external and internal knowledge sources in absence of cooperation and of conditional substitute relationship between external and cooperation knowledge sources in presence of internal source. In product and process innovation performance we found a conditional substitute relationship between internal and cooperation sources when external source is used and not used, respectively. This relationship turns to conditional complementarity in organisational innovation in absence of external knowledge source. Therefore, when designing innovation strategy, managers must consider their objectives on a priority basis, since not all the strategies have the same effects on innovation performance.

  15. Rotating-Disk-Based Hybridized Electromagnetic-Triboelectric Nanogenerator for Sustainably Powering Wireless Traffic Volume Sensors.

    Science.gov (United States)

    Zhang, Binbin; Chen, Jun; Jin, Long; Deng, Weili; Zhang, Lei; Zhang, Haitao; Zhu, Minhao; Yang, Weiqing; Wang, Zhong Lin

    2016-06-28

    Wireless traffic volume detectors play a critical role for measuring the traffic-flow in a real-time for current Intelligent Traffic System. However, as a battery-operated electronic device, regularly replacing battery remains a great challenge, especially in the remote area and wide distribution. Here, we report a self-powered active wireless traffic volume sensor by using a rotating-disk-based hybridized nanogenerator of triboelectric nanogenerator and electromagnetic generator as the sustainable power source. Operated at a rotating rate of 1000 rpm, the device delivered an output power of 17.5 mW, corresponding to a volume power density of 55.7 W/m(3) (Pd = P/V, see Supporting Information for detailed calculation) at a loading resistance of 700 Ω. The hybridized nanogenerator was demonstrated to effectively harvest energy from wind generated by a moving vehicle through the tunnel. And the delivered power is capable of triggering a counter via a wireless transmitter for real-time monitoring the traffic volume in the tunnel. This study further expands the applications of triboelectric nanogenerators for high-performance ambient mechanical energy harvesting and as sustainable power sources for driving wireless traffic volume sensors.

  16. Measurement uncertainty of ester number, acid number and patchouli alcohol of patchouli oil produced in Yogyakarta

    Science.gov (United States)

    Istiningrum, Reni Banowati; Saepuloh, Azis; Jannah, Wirdatul; Aji, Didit Waskito

    2017-03-01

    Yogyakarta is one of patchouli oil distillation center in Indonesia. The quality of patchouli oil greatly affect its market price. Therefore, testing quality of patchouli oil parameters is an important concern, one through determination of the measurement uncertainty. This study will determine the measurement uncertainty of ester number, acid number and content of patchouli alcohol through a bottom up approach. Source contributor to measurement uncertainty of ester number is a mass of the sample, a blank and sample titration volume, the molar mass of KOH, HCl normality, and replication. While the source contributor of the measurement uncertainty of acid number is the mass of the sample, the sample titration volume, the relative mass and normality of KOH, and repetition. Determination of patchouli alcohol by Gas Chromatography considers the sources of measurement uncertainty only from repeatability because reference materials are not available.

  17. Action plan for renewable energy sources

    International Nuclear Information System (INIS)

    2000-03-01

    In the Finnish Energy Strategy, approved by the Finnish Government in 1997, the emphasis is laid on the importance of bioenergy and other renewable energy sources for the creation of such prerequisites for the Finnish energy economy that the supply of energy can be secured, the price on energy is competitive and the emissions from energy generation are within the limits set by the international commitments made by Finland. In 1998, the European Union Meeting of the Ministers of Energy adopted a resolution taking a positive attitude to the Communication from the Commission 'Energy for the future: Renewable sources of energy' - White Paper for a Community Strategy and Action Plan. National measures play a key role in the achievement of the objectives set in the White Paper. This Action Plan for Renewable Energy Sources is a national programme in line with the EU's White Paper. It comprises all renewable sources of energy available in Finland. It encompasses even peat, which in Finland has traditionally been considered to be a solid biofuel but is internationally classified as one of the non-renewable sources of energy. In the Action Plan, objectives are set for the volume of renewable energy sources used in the year 2010 including a prognosis on the development by the year 2025. The goal is that by the year 2010 the volume of energy generated using renewable energy sources has increased by 50% compared with the year 1995. This would mean an increase by 3 Mtoe, which is about 1 Mtoe more than anticipated in the outlook based on the Finnish Energy Strategy. A further goal is to double the use of renewable energy sources by the year 2025. The aggregate use of renewable energy sources depends to a large extent both on the development of the price on energy produced using other energy sources and on possible changes in the production volume of the Finnish forest industry. The most important objective stated in the Action Plan is to improve the competitiveness of renewable

  18. Prehospital tidal volume influences hospital tidal volume: A cohort study.

    Science.gov (United States)

    Stoltze, Andrew J; Wong, Terrence S; Harland, Karisa K; Ahmed, Azeemuddin; Fuller, Brian M; Mohr, Nicholas M

    2015-06-01

    The purposes of the study are to describe current practice of ventilation in a modern air medical system and to measure the association of ventilation strategy with subsequent ventilator care and acute respiratory distress syndrome (ARDS). Retrospective observational cohort study of intubated adult patients (n = 235) transported by a university-affiliated air medical transport service to a 711-bed tertiary academic center between July 2011 and May 2013. Low tidal volume ventilation was defined as tidal volumes less than or equal to 8 mL/kg predicted body weight. Multivariable regression was used to measure the association between prehospital tidal volume, hospital ventilation strategy, and ARDS. Most patients (57%) were ventilated solely with bag valve ventilation during transport. Mean tidal volume of mechanically ventilated patients was 8.6 mL/kg predicted body weight (SD, 0.2 mL/kg). Low tidal volume ventilation was used in 13% of patients. Patients receiving low tidal volume ventilation during air medical transport were more likely to receive low tidal volume ventilation in the emergency department (P tidal volume (P = .840). Low tidal volume ventilation was rare during air medical transport. Air transport ventilation strategy influenced subsequent ventilation but was not associated with ARDS. Copyright © 2015 Elsevier Inc. All rights reserved.

  19. THE Q/U IMAGING EXPERIMENT: POLARIZATION MEASUREMENTS OF RADIO SOURCES AT 43 AND 95 GHz

    Energy Technology Data Exchange (ETDEWEB)

    Huffenberger, K. M. [Department of Physics, Florida State University, P.O. Box 3064350, Tallahassee, FL 32306-4350 (United States); Araujo, D.; Zwart, J. T. L. [Department of Physics and Columbia Astrophysics Laboratory, Columbia University, New York, NY 10027 (United States); Bischoff, C.; Buder, I. [Kavli Institute for Cosmological Physics, Department of Physics, Enrico Fermi Institute, The University of Chicago, Chicago, IL 60637 (United States); Chinone, Y.; Hasegawa, M. [High Energy Accelerator Research Organization (KEK), 1-1 Oho, Tsukuba, Ibaraki 305-0801 (Japan); Cleary, K. [Cahill Center for Astronomy and Astrophysics, California Institute of Technology, 1200 E. California Blvd M/C 249-17, Pasadena, CA 91125 (United States); Kusaka, A. [Physics Division, Lawrence Berkeley National Laboratory, 1 Cyclotron Road, Berkeley, CA 94720 (United States); Monsalve, R. [School of Earth and Space Exploration, Arizona State University, 781 E. Terrace Road, Tempe, AZ 85287 (United States); Næss, S. K. [Department of Astrophysics, University of Oxford, Keble Road, Oxford, OX1 3RH (United Kingdom); Newburgh, L. B. [Dunlap Institute, University of Toronto, 50 St. George Street, Toronto, ON M5S 3H4 (Canada); Reeves, R. [CePIA, Departamento de Astronomía, Universidad de Concepción (Chile); Ruud, T. M.; Eriksen, H. K. [Institute of Theoretical Astrophysics, University of Oslo, P.O. Box 1029 Blindern, NO-0315 Oslo (Norway); Wehus, I. K.; Gaier, T. [Jet Propulsion Laboratory, California Institute of Technology, 4800 Oak Grove Drive, Pasadena, CA 91109 (United States); Dickinson, C. [Jodrell Bank Centre for Astrophysics, Alan Turing Building, School of Physics and Astronomy, The University of Manchester, Oxford Road, Manchester M13 9PL (United Kingdom); Gundersen, J. O., E-mail: huffenbe@physics.fsu.edu [Department of Physics, University of Miami, 1320 Campo Sano Drive, Coral Gables, FL 33146 (United States); Collaboration: QUIET Collaboration; and others

    2015-06-10

    We present polarization measurements of extragalactic radio sources observed during the cosmic microwave background polarization survey of the Q/U Imaging Experiment (QUIET), operating at 43 GHz (Q-band) and 95 GHz (W-band). We examine sources selected at 20 GHz from the public, >40 mJy catalog of the Australia Telescope (AT20G) survey. There are ∼480 such sources within QUIET’s four low-foreground survey patches, including the nearby radio galaxies Centaurus A and Pictor A. The median error on our polarized flux density measurements is 30–40 mJy per Stokes parameter. At signal-to-noise ratio > 3 significance, we detect linear polarization for seven sources in Q-band and six in W-band; only 1.3 ± 1.1 detections per frequency band are expected by chance. For sources without a detection of polarized emission, we find that half of the sources have polarization amplitudes below 90 mJy (Q-band) and 106 mJy (W-band), at 95% confidence. Finally, we compare our polarization measurements to intensity and polarization measurements of the same sources from the literature. For the four sources with WMAP and Planck intensity measurements >1 Jy, the polarization fractions are above 1% in both QUIET bands. At high significance, we compute polarization fractions as much as 10%–20% for some sources, but the effects of source variability may cut that level in half for contemporaneous comparisons. Our results indicate that simple models—ones that scale a fixed polarization fraction with frequency—are inadequate to model the behavior of these sources and their contributions to polarization maps.

  20. Monte Carlo calculations and measurements of spectra from a C-14 source

    International Nuclear Information System (INIS)

    Borg, J.

    1996-05-01

    To perform Monte Carlo simulations it is necessary to model the physical geometries i.e., the source and detector geometry. However, a complete model of the physical geometry may not be possible or may result in a very low calculation efficiency. Substituting the complete source model with a simplified model is one way of increasing the calculation efficiency. In this report, the study of a simplified model of a 14 C source is described. Results of Monte Carlo calculations with the EGS4 code are compared with measurements with a β spectrometer consisting of two coaxial Si detectors, and a low-energy photon spectrometer being a Si(Li) detector. Calculations and measurements show generally good agreement. However, the difference (a factor of 4) between calculated and measured response to electrons for the Si(Li) detector indicates that this detector has a dead layer about 12 μm thick instead of 0.2 μm as reported by the manufacturer. The efficiency of the calculations is increased by a factor of 10, when the complete source model is replaced by the simplified source model. This reduces the calculation time of detector responses to a few days instead of weeks on the NRC SGI R4400 computers. Good agreement between measured and calculated data also verifies that the MC code EGS4 is a reliable and useful tool for simulating coupled electron and photon transport for particles with energies down to a few keV. (au) 3 tabs., 15 ills., 11 refs